WorldWideScience

Sample records for refill response time

  1. An automated quasi-continuous capillary refill timing device

    International Nuclear Information System (INIS)

    Blaxter, L L; Morris, D E; Crowe, J A; Hayes-Gill, B R; Henry, C; Hill, S; Sharkey, D; Vyas, H

    2016-01-01

    Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of the skin surface. There is evidence to suggest that manually assessed CRT is subject to bias from ambient light conditions, a lack of standardisation of both blanching time and manually applied pressure, subjectiveness of return to normal colour, and variability in the manual assessment of time. We present a novel automated system for CRT measurement, incorporating three components: a non-invasive adhesive sensor incorporating a pneumatic actuator, a diffuse multi-wavelength reflectance measurement device, and a temperature sensor; a battery operated datalogger unit containing a self contained pneumatic supply; and PC based data analysis software for the extraction of refill time, patient skin surface temperature, and sensor signal quality. Through standardisation of the test, it is hoped that some of the shortcomings of manual CRT can be overcome. In addition, an automated system will facilitate easier integration of CRT into electronic record keeping and clinical monitoring or scoring systems, as well as reducing demands on clinicians. Summary analysis of volunteer (n  =  30) automated CRT datasets are presented, from 15 healthy adults and 15 healthy children (aged from 5 to 15 years), as their arms were cooled from ambient temperature to 5°C. A more detailed analysis of two typical datasets is also presented, demonstrating that the response of automated CRT to cooling matches that of previously published studies. (paper)

  2. Beyond the basics: refills by electronic prescribing.

    Science.gov (United States)

    Goldman, Roberta E; Dubé, Catherine; Lapane, Kate L

    2010-07-01

    E-prescribing is part of a new generation of electronic solutions for the medical industry that may have great potential for improving work flow and communication between medical practices and pharmacies. In the US, it has been introduced with minimal monitoring of errors and general usability. This paper examines refill functionality in e-prescribing software. A mixed method study including focus groups and surveys was conducted. Qualitative data were collected in on-site focus groups or individual interviews with clinicians and medical office staff at 64 physician office practices. Focus group participants described their experiences with the refill functionality of e-prescribing software, provided suggestions for improving it, and suggested improvements in office procedures and software functionality. Overall, approximately 50% reduction in time spent each day on refills was reported. Overall reports of refill functionality were positive; but clinicians and staff identified numerous difficulties and glitches associated managing prescription refills. These glitches diminished over time. Benefits included time saved as well as patient convenience. Potential for refilling without thought because of the ease of use was noted. Clinicians and staff appreciated the ability to track whether patients are filling and refilling prescriptions. E-prescribing software for managing medication refills has not yet reached its full potential. To reduce work flow barriers and medication errors, software companies need to develop error reporting systems and response teams to deal effectively with problems experienced by users. Examining usability issues on both the medical office and pharmacy ends is required to identify the behavioral and cultural changes that accompany technological innovation and ease the transition to full use of e-prescribing software. 2010 Elsevier Ireland Ltd. All rights reserved.

  3. Does switching contraceptive from oral to a patch or vaginal ring change the likelihood of timely prescription refill?

    Science.gov (United States)

    Law, Amy; Lee, Yi-Chien; Gorritz, Magdaliz; Plouffe, Leo

    2014-08-01

    This study evaluated contraceptive refill patterns of women insured commercially in the US who switched from oral contraceptives (OCs) to the patch or vaginal ring and assessed if switching contraceptive methods changes refill patterns. Women aged 15-44 with ≥2 patch or ring prescriptions and ≥2 OC prescriptions before the first patch/ring prescription were identified from the MarketScan® Commercial database (1/1/2002-6/30/2011). Refill patterns 1-year pre- and postindex date (first patch/ring prescription) were evaluated, and women were categorized as timely or delayed refillers on OCs and patch/ring. Regression modeling was used to investigate the association between refill patterns and contraceptive methods and switching effects on refill patterns. Of 17,814 women identified, 7901 switched to the patch, and 9913 switched to the ring. Among timely OC refillers, the percentage of timely refills decreased (patch: 95.6% to 79.4%, pcontraceptive efficacy by simply switching to the patch or ring. The impact on timely refills of switching from OCs to either the patch or ring is complex and varies depending on the pattern of timely refills on OCs. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. A novel imaging technique to measure capillary-refill time: improving diagnostic accuracy for dehydration in young children with gastroenteritis.

    Science.gov (United States)

    Shavit, Itai; Brant, Rollin; Nijssen-Jordan, Cheri; Galbraith, Roger; Johnson, David W

    2006-12-01

    Assessment of dehydration in young children currently depends on clinical judgment, which is relatively inaccurate. By using digital videography, we developed a way to assess capillary-refill time more objectively. Our goal was to determine whether digitally measured capillary-refill time assesses the presence of significant dehydration (> or = 5%) in young children with gastroenteritis more accurately than conventional capillary refill and overall clinical assessment. We prospectively enrolled children with gastroenteritis, 1 month to 5 years of age, who were evaluated in a tertiary-care pediatric emergency department and judged by a triage nurse to be at least mildly dehydrated. Before any treatment, we measured the weight and digitally measured capillary-refill time of these children. Pediatric emergency physicians determined capillary-refill time by using conventional methods and degree of dehydration by overall clinical assessment by using a 7-point Likert scale. Postillness weight gain was used to estimate fluid deficit; beginning 48 hours after assessment, children were reweighed every 24 hours until 2 sequential weights differed by no more than 2%. We compared the accuracy of digitally measured capillary-refill time with conventional capillary refill and overall clinical assessment by determining sensitivities, specificities, likelihood ratios, and area under the receiver operator characteristic curves. A total of 83 patients were enrolled and had complete follow-up; 13 of these patients had significant dehydration (> or = 5% of body weight). The area under the receiver operator characteristic curves for digitally measured capillary-refill time and overall clinical assessment relative to fluid deficit ( or = 5%) were 0.99 and 0.88, respectively. Positive likelihood ratios were 11.7 for digitally measured capillary-refill time, 4.5 for conventional capillary refill, and 4.1 for overall clinical assessment. Results of this prospective cohort study suggest

  5. The Diagnostic Value of Capillary Refill Time for Detecting Serious Illness in Children: A Systematic Review and Meta-Analysis

    Science.gov (United States)

    Fleming, Susannah; Gill, Peter; Jones, Caroline; Taylor, James A.; Van den Bruel, Ann; Heneghan, Carl; Roberts, Nia; Thompson, Matthew

    2015-01-01

    Importance Capillary refill time (CRT) is widely recommended as part of the routine assessment of unwell children. Objective To determine the diagnostic value of capillary refill time for a range of serious outcomes in children. Methods We searched Medline, Embase and CINAHL from inception to June 2014. We included studies that measured both capillary refill time and a relevant clinical outcome such as mortality, dehydration, meningitis, or other serious illnesses in children aged up to 18 years of age. We screened 1,265 references, of which 24 papers were included in this review. Where sufficient studies were available, we conducted meta-analysis and constructed hierarchical summary ROC curves. Results Meta-analysis on the relationship between capillary refill time and mortality resulted in sensitivity of 34.6% (95% CI 23.9 to 47.1%), specificity 92.3% (88.6 to 94.8%), positive likelihood ratio 4.49 (3.06 to 6.57), and negative likelihood ratio 0.71 (0.60 to 0.84). Studies of children attending Emergency Departments with vomiting and diarrhea showed that capillary refill time had specificity of 89 to 94% for identifying 5% dehydration, but sensitivity ranged from 0 to 94%. This level of heterogeneity precluded formal meta-analysis of this outcome. Meta-analysis was not possible for other outcomes due to insufficient data, but we found consistently high specificity for a range of outcomes including meningitis, sepsis, admission to hospital, hypoxia, severity of illness and dengue. Conclusions Our results show that capillary refill time is a specific sign, indicating that it can be used as a “red-flag”: children with prolonged capillary refill time have a four-fold risk of dying compared to children with normal capillary refill time. The low sensitivity means that a normal capillary refill time should not reassure clinicians. PMID:26375953

  6. Effects of a direct refill program for automated dispensing cabinets on medication-refill errors.

    Science.gov (United States)

    Helmons, Pieter J; Dalton, Ashley J; Daniels, Charles E

    2012-10-01

    The effects of a direct refill program for automated dispensing cabinets (ADCs) on medication-refill errors were studied. This study was conducted in designated acute care areas of a 386-bed academic medical center. A wholesaler-to-ADC direct refill program, consisting of prepackaged delivery of medications and bar-code-assisted ADC refilling, was implemented in the inpatient pharmacy of the medical center in September 2009. Medication-refill errors in 26 ADCs from the general medicine units, the infant special care unit, the surgical and burn intensive care units, and intermediate units were assessed before and after the implementation of this program. Medication-refill errors were defined as an ADC pocket containing the wrong drug, wrong strength, or wrong dosage form. ADC refill errors decreased by 77%, from 62 errors per 6829 refilled pockets (0.91%) to 8 errors per 3855 refilled pockets (0.21%) (p error type detected before the intervention was the incorrect medication (wrong drug, wrong strength, or wrong dosage form) in the ADC pocket. Of the 54 incorrect medications found before the intervention, 38 (70%) were loaded in a multiple-drug drawer. After the implementation of the new refill process, 3 of the 5 incorrect medications were loaded in a multiple-drug drawer. There were 3 instances of expired medications before and only 1 expired medication after implementation of the program. A redesign of the ADC refill process using a wholesaler-to-ADC direct refill program that included delivery of prepackaged medication and bar-code-assisted refill significantly decreased the occurrence of ADC refill errors.

  7. Mobile phone use for a social strategy to improve antiretroviral refill experience at a low-resource HIV clinic: patient responses from Nigeria.

    Science.gov (United States)

    Adetunji, Adedotun A; Muyibi, Sufiyan A; Imhansoloeva, Martins; Ibraheem, Olusola M; Sunmola, Adegbenga; Kolawole, Olubunmi O; Akinrinsola, Oluwasina O; Ojo-Osagie, James O; Mosuro, Olusola A; Abiolu, Josephine O; Irabor, Achiaka E; Okonkwo, Prosper; Adewole, Isaac F; Taiwo, Babafemi O

    2017-05-01

    In sub-Saharan African areas where antiretroviral (ARV) drugs are not available through community pharmacies, clinic-based pharmacies are often the primary source of ARV drug refills. Social pressure is mounting on treatment providers to adjust ARV refill services towards user-friendly approaches which prioritize patients' convenience and engage their resourcefulness. By this demand, patients may be signalling dissatisfaction with the current provider-led model of monthly visits to facility-based pharmacies for ARV refill. Mobile phones are increasingly popular in sub-Saharan Africa, and have been used to support ARV treatment goals in this setting. A patient-centred response to on-going social pressure requires treatment providers to view ARV refill activities through the eyes of patients who are negotiating the challenges of day-to-day life while contemplating their next refill appointment. Using focus groups of five categories of adult patients receiving combination ARV therapy, we conducted this cross-sectional qualitative study to provide insight into modifiable gaps between patients' expectations and experiences of the use of mobile phones in facility-based ARV refill service at a public HIV clinic in Nigeria. A notable finding was patients' preference for harnessing informal social support (through intermediaries with mobile phones) to maintain adherence to ARV refill appointments when they could not present in person. This evolving social support strategy also has the potential to enhance defaulter tracking. Our study findings may inform the development of ARV refill strategies and the design of future qualitative studies on client-provider communication by mobile phones in under-resourced HIV treatment programmes.

  8. 40 CFR 165.45 - Refillable container standards.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Refillable container standards. 165.45... PESTICIDE MANAGEMENT AND DISPOSAL Refillable Container Standards: Container Design § 165.45 Refillable container standards. (a) What Department of Transportation (DOT) standards do my refillable containers have...

  9. Disparities in the Use of Internet and Telephone Medication Refills among Linguistically Diverse Patients.

    Science.gov (United States)

    Moreno, Gerardo; Lin, Elizabeth H; Chang, Eva; Johnson, Ron L; Berthoud, Heidi; Solomon, Cam C; Morales, Leo S

    2016-03-01

    Health systems are increasingly implementing remote telephone and Internet refill systems to enhance patient access to medication refills. Remote refill systems may provide an effective approach for improving medication non-adherence, but more research is needed among patients with limited English proficiency with poor access to remote refill systems. To compare the use of remote medication refill systems among limited-English-proficiency (LEP) and English-proficient (EP) patients with chronic conditions. Cross-sectional survey in six languages/dialects (English, Cantonese, Mandarin, Korean, Vietnamese, and Spanish) of 509 adults with diabetes, hypertension, or hyperlipidemia. Primary study outcomes were self-reported use of 1) Internet refills, 2) telephone refills, and 3) any remote refill system. LEP was measured by patient self-identification of a primary language other than English and a claims record of use of an interpreter. Other measures were age, gender, education, years in the U.S., insurance, health status, chronic conditions, and number of prescribed medications. Analyses included multivariable logistic regression weighted for survey non-response. Overall, 33.1 % of patients refilled their medications by telephone and 31.6 % by Internet. Among LEP patients (n = 328), 31.5 % refilled by telephone and 21.2 % by Internet, compared with 36.7 % by telephone and 52.7 % by Internet among EP patients (n = 181). Internet refill by language groups were as follows: English (52.7 %), Cantonese (34.9 %), Mandarin (17.4 %), Korean (16.7 %), Vietnamese (24.4 %), and Spanish (12.6 %). Compared to EP patients, LEP patients had lower use of any remote refill system (adjusted odds ratio [AOR] 0.18; p use any remote medication refill system. Increased reliance on current systems for remote medication refills may increase disparities in health outcomes affecting LEP patients with poor access to telephone and Internet medication refills.

  10. Challenges in automated estimation of capillary refill time in dogs

    Science.gov (United States)

    Cugmas, Blaž; Spigulis, Janis

    2018-02-01

    Capillary refill time (CRT) is a part of the cardiorespiratory examination in dogs. Changes in CRT can reflect pathological conditions like shock or anemia. Visual CRT estimation has low repeatability; therefore, optical systems for automated estimation have recently appeared. Since existing systems are unsuitable for use in dogs, we designed a simple, small and portable device, which could be easily used at veterinary clinic. The device was preliminarily tested on several measurement sites in two dogs. Not all measurement sites were suitable for CRT measurements due to underlying tissue optical and mechanical properties. The CRT measurements were possible on the labial mucosa, above the sternum and on the digit where CRT was in the range of values, retrieved from the color video of the visual CRT measurement. It seems that light penetration predominantly governs tissue optical response when the pressure is applied. Therefore, it is important to select a proper light, which reaches only superficial capillaries and does not penetrate deeper. Blue or green light is probably suitable for light skin or mucosa, on the other hand, red or near-infrared might be used for skin with pigmented or thick epidermis. Additionally, further improvements of the device design are considered, like adding a calibrated spring, which would insure application of consistent pressure.

  11. AMO's [Association of Municipalities of Ontario] policy on refillable beverage containers

    Energy Technology Data Exchange (ETDEWEB)

    1992-04-01

    The policy of the Association of Municipalities of Ontario (AMO) regarding refillable beverage containers is explained, and a response is made to the Ontario Soft Drink Association (OSDA's) top-up offer to municipalities. A background and overview is presented of current and historical policy on beverage containers, including measures enacted by other provinces and countries. AMO strongly urges the provincial government to increase the presence of refillable containers, first because reuse is preferrable to recycling, and second because Ontario's current recycling systems are not self-sufficient or sustainable in their present form. Refillable plastic bottles offer an opportunity for change in waste management similar to the Blue Box recycling initiative. It is recommended that the entire beverage industry voluntarily, or legislated by the provincial government, provide refillable containers as a consumer option and institute a deposit system to collect these containers. This system will promote full-cost accounting. OSDA's offer to top up Blue Box operating costs is rejected with the caveat of short-term financial agreements. The refillable concept should also be expanded to other packaged products. 2 tabs.

  12. Fuel channel refilling

    International Nuclear Information System (INIS)

    Shoukri, M.; Abdul-Razzak, A.

    1990-04-01

    Analysis of existing data on fuel channel refilling is presented. The analysis focuses on the data obtained using the Stern Laboratories Cold Water Injection Test (CWIT) Facility. The two-fluid model thermal-hydraulics computer code CATHENA is also used to simulate experimental results on fuel channel refilling from both the CWIT and RD-14 facilities. Conclusions related to single and double break tests, including the effect of non-condensible gases, are presented. A set of recommendations is given for further analysis and separate effect experiments. (67 figs., 5 tabs., 24 refs.)

  13. BWR Refill-Reflood Program. Final report

    International Nuclear Information System (INIS)

    Myers, L.L.

    1983-09-01

    The BWR Refill-Reflood Program is part of the continuing Loss of Coolant Accident (LOCA) research in the United States which is jointly sponsored by the Nuclear Regulatory Commission, the Electric Power Research Institute, and the General Electric Company. The current program expanded the focus of this research to include full scale experimental evaluations of multidimensional and multichannel effects during system refill. The program has also made major contributions to the BWR version of the Transient Reactor Analysis Code (TRAC) which has been developed cooperatively with the Idaho National Engineering Laboratory (INEL) for application to BWR transients. A summary description of the complete program is provided including the principal findings and main conclusions of the program. The results of the program have shown that multidimensional and parallel channel effects have the potential to significantly improve the system response over that observed in single channel tests

  14. The Dynamics of Embolism Refilling in Abscisic Acid (ABA-Deficient Tomato Plants

    Directory of Open Access Journals (Sweden)

    Francesca Secchi

    2012-12-01

    Full Text Available Plants are in danger of embolism formation in xylem vessels when the balance between water transport capacity and transpirational demand is compromised. To maintain this delicate balance, plants must regulate the rate of transpiration and, if necessary, restore water transport in embolized vessels. Abscisic acid (ABA is the dominant long-distance signal responsible for plant response to stress, and it is possible that it plays a role in the embolism/refilling cycle. To test this idea, a temporal analysis of embolism and refilling dynamics, transpiration rate and starch content was performed on ABA-deficient mutant tomato plants. ABA-deficient mutants were more vulnerable to embolism formation than wild-type plants, and application of exogenous ABA had no effect on vulnerability. However, mutant plants treated with exogenous ABA had lower stomatal conductance and reduced starch content in the xylem parenchyma cells. The lower starch content could have an indirect effect on the plant’s refilling activity. The results confirm that plants with high starch content (moderately stressed mutant plants were more likely to recover from loss of water transport capacity than plants with low starch content (mutant plants with application of exogenous ABA or plants experiencing severe water stress. This study demonstrates that ABA most likely does not play any direct role in embolism refilling, but through the modulation of carbohydrate content, it could influence the plant’s capacity for refilling.

  15. Fuel channel refilling

    International Nuclear Information System (INIS)

    Shoukri, M.; Abdul-Razzak, A.

    1992-11-01

    This report extends the work reported in document INFO-0370 on fuel channel refilling by providing analysis of the refilling tests conducted using the RD-14 and RD-14M test facilities. The analysis focuses on the general thermal-hydraulic characteristics of the facilities following various small and large inlet and outlet header breaks with emergency coolant injection. The two-fluid model thermal-hydraulic computer code CATHENA was tested against results obtained from selected experiments carried out in the two facilities. Conclusions related to the effect of break size, mode of emergency core injection, primary pump operation and parallel channels are presented. (Author) (116 figs., 17 tabs., 53 refs.)

  16. Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb.

    Science.gov (United States)

    Henricson, Joakim; Toll John, Rani; Anderson, Chris D; Björk Wilhelms, Daniel

    2017-12-02

    The capillary refill test was introduced in 1947 to help estimate circulatory status in critically ill patients. Guidelines commonly state that refill should occur within 2 s after releasing 5 s of firm pressure (e.g., by the physician's finger) in the normal healthy supine patient. A slower refill time indicates poor skin perfusion, which can be caused by conditions including sepsis, blood loss, hypoperfusion, and hypothermia. Since its introduction, the clinical usefulness of the test has been debated. Advocates point out its feasibility and simplicity and claim that it can indicate changes in vascular status earlier than changes in vital signs such as heart rate. Critics, on the other hand, stress that the lack of standardization in how the test is performed and the highly subjective nature of the naked eye assessment, as well as the test's susceptibility to ambient factors, markedly lowers the clinical value. The aim of the present work is to describe in detail the course of the refill event and to suggest potentially more objective and exact endpoint values for the capillary refill test using diffuse polarization spectroscopy.

  17. The Power of Flash Mob Research Conducting a Nationwide Observational Clinical Study on Capillary Refill Time in a Single Day

    NARCIS (Netherlands)

    Alsma, Jelmer; van Saase, Jan L. C. M.; Nanayakkara, Prabath W. B.; Schouten, W. E. M. Ineke; Baten, Anique; Bauer, Martijn P.; Holleman, Frits; Ligtenberg, Jack J. M.; Stassen, Patricia M.; Kaasjager, Karin H. A. H.; Haak, Harm R.; Bosch, Frank H.; Schuit, Stephanie C. E.

    BACKGROUND: Capillary refill time (CRT) is a clinical test used to evaluate the circulatory status of patients; various methods are available to assess CRT. Conventional clinical research often demands large numbers of patients, making it costly, labor-intensive, and time-consuming. We studied the

  18. Energy contribution of sugar-sweetened beverage refills at fast-food restaurants.

    Science.gov (United States)

    Breck, Andrew; Cantor, Jonathan H; Elbel, Brian

    2017-09-01

    To identify demographic and consumer characteristics associated with refilling a soft drink at fast-food restaurants and the estimated energy content and volume of those refills. Logistic and linear regression with cross-sectional survey data. Data include fast-food restaurant receipts and consumer surveys collected from restaurants in New York City (all boroughs except Staten Island), and Newark and Jersey City, New Jersey, during 2013 and 2014. Fast-food restaurant customers (n 11795) from ninety-eight restaurants. Thirty per cent of fast-food customers ordered a refillable soft drink. Nine per cent of fast-food customers with a refillable soft drink reported refilling their beverage (3 % of entire sample). Odds of having a beverage refill were higher among respondents with a refillable soft drink at restaurants with a self-serve refill kiosk (adjusted OR (aOR)=7·37, Prestaurant (aOR=4·45, P<0·001). KFC (aOR=2·18, P<0·001) and Wendy's (aOR=0·41, P<0·001) customers had higher and lower odds, respectively, of obtaining a refill, compared with Burger King customers. Respondents from New Jersey (aOR=1·47, P<0·001) also had higher odds of refilling their beverage than New York City customers. Customers who got a refill obtained on average 29 more 'beverage ounces' (858 ml) and 250 more 'beverage calories' (1046 kJ) than customers who did not get a refill. Refilling a beverage was associated with having obtained more beverage calories and beverage ounces. Environmental cues, such as the placement and availability of self-serve beverage refills, may influence consumer beverage choice.

  19. Airflow obstruction among street vendors who refill cigarette lighters with liquefied petroleum gas.

    Science.gov (United States)

    Moitra, S; Blanc, P D; Brashier, B B

    2014-09-01

    Manual cigarette lighter refilling with butane/propane admixed liquefied petroleum gas (LPG) is a common low-income occupation in India. This practice may cause adverse health effects from LPG exposure among such workers. To assess respiratory status among LPG-exposed workers and non-exposed controls. We quantified the exposure and evaluated respiratory symptoms and lung function among 113 LPG refilling workers (aged 41.9±9.9 years) and 79 controls (aged 40.8±7.2 years). We used multiple linear regression analysis to estimate the LPG exposure response within the group of refilling workers, adjusting for age, height and smoking status. Compared to the controls, the LPG-exposed lighter refillers manifested a 190 ml decrement in 1-second forced expiratory volume (FEV1) (2.55±0.4 vs. 2.26±0.3 l) and a 6% decrement in FEV1/forced vital capacity (FVC) (both P decrements. This adverse effect may be relevant to other occupational groups heavily exposed to volatile hydrocarbons, especially those in marginal employment sectors.

  20. Economical and ecological comparison of granular activated carbon (GAC) adsorber refill strategies.

    Science.gov (United States)

    Bayer, Peter; Heuer, Edda; Karl, Ute; Finkel, Michael

    2005-05-01

    Technical constraints can leave a considerable freedom in the design of a technology, production or service strategy. Choosing between economical or ecological decision criteria then characteristically leads to controversial solutions of ideal systems. For the adaptation of granular-activated carbon (GAC) fixed beds, various technical factors determine the adsorber volume required to achieve a desired service life. In considering carbon replacement and recycling, a variety of refill strategies are available that differ in terms of refill interval, respective adsorber volume, and time-dependent use of virgin, as well as recycled GAC. Focusing on the treatment of contaminant groundwater, we compare cost-optimal reactor configurations and refill strategies to the ecologically best alternatives. Costs and consumption of GAC are quantified within a technical-economical framework. The emissions from GAC production out of hard coal, transport and recycling are equally derived through a life cycle impact assessment. It is shown how high discount rates lead to a preference of small fixed-bed volumes, and accordingly, a high number of refills. For fixed discount rates, the investigation reveals that both the economical as well as ecological assessment of refill strategies are especially sensitive to the relative valuation of virgin and recycled GAC. Since recycling results in economic and ecological benefits, optimized systems thus may differ only slightly.

  1. Colour cues facilitate learning flower refill schedules in wild hummingbirds.

    Science.gov (United States)

    Samuels, Michael; Hurly, T Andrew; Healy, Susan D

    2014-11-01

    Free-living hummingbirds can learn the refill schedules of individual experimental flowers but little is known about what information they use to do this. Colour cues, in particular, may be important to hummingbirds when learning about rewarded flower properties. We investigated, therefore, whether colour cues facilitated the learning of flower refill schedules in wild, free-living rufous hummingbirds (Selasphorus rufus). In the Cued condition, we presented birds with an array of six flowers, three of one colour, each of which were refilled 10min after being emptied by the bird and three of a different colour, which were refilled 20min after being emptied. In the Uncued condition we presented birds with six flowers of the same colour, three of which were refilled after 10min and three of which were refilled after 20min as for the birds in the Cued condition. In the second part of the experiment, we moved the array 2m and changed the shape of the array. Across both phases, birds in the Cued condition learned to discriminate between 10 and 20-min flowers more quickly than did the birds in the Uncued condition. The Cued birds were also better at discriminating between the two distinct refill intervals. Colour cues can, therefore, facilitate learning the refill schedules of experimental flowers in these birds. This article is part of a Special Issue entitled: Cognition in the wild. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Capillary refill time is an unreliable indicator of cardiovascular status in term neonates.

    Science.gov (United States)

    LeFlore, Judy L; Engle, William D

    2005-06-01

    Decisions regarding the need for volume replacement in neonates often are made in the immediate newborn period. Capillary refill time (CRT) is used as an indicator of circulatory status; however, recent data show that CRT varies considerably with age, ambient and skin temperature, anatomical site of measurement, and duration of pressure. The purpose of this study was to (1) examine the relationship between CRT and heart rate (HR) and blood pressure (BP) in term neonates, and (2) evaluate the differences among CRT values measured at 3 body sites and with varying duration of cutaneous pressure. This was a prospective, cross-sectional, correlational study. Subjects Forty-two appropriate-weight-for-gestational-age (AGA) neonates with birthweights, (M = 3407; SD = +/- 540 g), gestational ages (M = 39 weeks; SD = +/- 1 week), and sex (21 males, 21 females). Infants had no history of perinatal distress or maternal chorioamnionitis. Each neonate was studied prospectively 1 to 4 hours after birth. The infants were clothed with only a diaper and evaluated on a radiant warmer bed set to achieve an axillary temperature of 36.5 degrees to 37.0 degrees C. Capillary refill time was measured with a digital stopwatch at 3 sites: volar surface of finger (F), plantar surface of heel (H), and lower sternum (St), using brief (1- to 2-second) and extended (3- to 4-second) pressure. Heart rate was auscultated and counted for 60 seconds, and BP was measured by oscillometry. Relationships among variables were assessed by Pearson correlation coefficient, analysis of variance, and multiple regression analysis. The Bonferroni correction for multiple comparisons was applied. Capillary refill time, blood pressure, and heart rate. There was no significant site variation for CRT for either brief (2.4 +/- 0.6 to 2.9 +/- 1.0 seconds) or extended (3.8 +/- 0.8 to 4.3 +/- 0.8 seconds) pressure. However, regardless of site, CRT was greater when extended versus brief pressure was used (P correlations

  3. The switch to refillable bottled water in Indonesia: a serious health risk.

    Science.gov (United States)

    Komarulzaman, Ahmad; de Jong, Eelke; Smits, Jeroen

    2017-10-01

    In recent years, the consumption of refillable bottled water has increased considerably in emerging countries. However, the quality of this water is often questionable, as authorities lack the capacity to properly check refilling depots. Given that refillable bottled water not only replaces unimproved water sources, but also better-quality sources, like piped and branded bottled water, its increasing use poses a major health risk. We investigate the motives behind the decision to switch to refillable bottled water in Indonesia. Findings indicate that this switch is driven by lifestyle motives, as well as by cost and availability considerations. It is mostly the young affluent households who switch from piped and 'other' sources to refillable bottled water. In rural areas, the tendency to make this switch is negatively affected by availability problems and the higher price of refillable bottled water. Availability and cost also influence the switch from branded bottled to refillable bottled water, but here it is the poorer households who have a higher propensity to switch. Further exploration of the lifestyle motive and affordability issues, as well as better monitoring of the refilling depots, are needed to improve the quality of drinking water in Indonesia and other emerging countries.

  4. Transdermal nicotine absorption handling e-cigarette refill liquids.

    Science.gov (United States)

    Maina, Giovanni; Castagnoli, Carlotta; Passini, Valter; Crosera, Matteo; Adami, Gianpiero; Mauro, Marcella; Filon, Francesca Larese

    2016-02-01

    The concentrated nicotine in e-cigarette refill liquids can be toxic if inadvertently ingested or absorbed through the skin. Reports of poisonings due to accidental ingestion of nicotine on refill liquids are rapidly increasing, while the evaluation of nicotine dermally absorbed still lacks. For that reason we studied transdermal nicotine absorption after the skin contamination with e-liquid. Donor chambers of eight Franz diffusion cells were filled with 1 mL of 0.8 mg/mL nicotine e-liquid for 24 h. The concentration of nicotine in the receiving phase was determined by high-performance liquid chromatography (LOD:0.1 μg/mL). Nicotine was detectable in receiving solution 2 h after the start of exposure and increased progressively. The medium flux calculated was 4.82 ± 1.05 μg/cm(2)/h with a lag time of 3.9 ± 0.1 h. After 24 h, the nicotine concentration in the receiving compartment was 101.02 ± 22.35 μg/cm(2) corresponding to 3.04 mg of absorbed nicotine after contamination of a skin surface of 100 cm(2). Skin contamination with e-liquid can cause nicotine skin absorption: caution must be paid when handling refill e-liquids. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Relation between injected volume and optical parameters in refilled isolated porcine lenses

    NARCIS (Netherlands)

    Koopmans, SA; Terwee, T; Haitjema, HJ; Deuring, H; van Aarle, S; Kooijman, AC

    2004-01-01

    Purpose: This study was performed to elucidate the correlation between added lens refill material and enhanced lens power as well as the correlation between lens refilling volume and accommodative amplitude as determined by equatorial stretching of ex vivo refilled pigs' lenses. Methods: Nine

  6. The switch to refillable bottled water in Indonesia: a serious health risk

    NARCIS (Netherlands)

    Komarulzaman, A.; Jong, E. de; Smits, J.P.J.M.

    2017-01-01

    In recent years, the consumption of refillable bottled water has increased considerably in emerging countries. However, the quality of this water is often questionable, as authorities lack the capacity to properly check refilling depots. Given that refillable bottled water not only replaces

  7. Changes in lens stiffness due to capsular opacification in accommodative lens refilling

    NARCIS (Netherlands)

    Nibourg, Lisanne M.; Sharma, Prashant K.; van Kooten, Theo G.; Koopmans, Steven A.

    Accommodation may be restored to presbyopic lenses by refilling the lens capsular bag with a soft polymer. After this accommodative lens refilling prevention of capsular opacification is a requirement, since capsular opacification leads to a decreased clarity of the refilled lens. It has been

  8. Transdermal power transfer for recharging implanted drug delivery devices via the refill port.

    Science.gov (United States)

    Evans, Allan T; Chiravuri, Srinivas; Gianchandani, Yogesh B

    2010-04-01

    This paper describes a system for transferring power across a transdermal needle into a smart refill port for recharging implantable drug delivery systems. The device uses a modified 26 gauge (0.46 mm outer diameter) Huber needle with multiple conductive elements designed to couple with mechanical springs in the septum of the refill port of a drug delivery device to form an electrical connection that can sustain the current required to recharge a battery during a reservoir refill session. The needle is fabricated from stainless steel coated with Parylene, and the refill port septum is made from micromachined stainless steel contact springs and polydimethylsiloxane. The device properties were characterized with dry and wet ambient conditions. The needle and port pair had an average contact resistance of less than 2 Omega when mated in either environment. Electrical isolation between the system, the liquid in the needle lumen, and surrounding material has been demonstrated. The device was used to recharge a NiMH battery with currents up to 500 mA with less than 15 degrees C of resistive heating. The system was punctured 100 times to provide preliminary information with regard to device longevity, and exhibited about 1 Omega variation in contact resistance. The results suggest that this needle and refill port system can be used in an implant to enable battery recharging. This allows for smaller batteries to be used and ultimately increases the volume efficiency of an implantable drug delivery device.

  9. Refilling material for underground disposal of radioactive waste

    International Nuclear Information System (INIS)

    Yajima, Tatsuya; Kato, Hiroyasu.

    1995-01-01

    Generally, the underground circumstance where radioactive wastes are to be processed is in high pH and highly ionized state due to ingredients leached out of cement of a concrete pit and solidifying products. A refilling material for underground disposal are demanded to adsorb radioactive nuclides such as 137 Cs even in such a state. As the refilling material, a mixture of bentonite and sintered vermiculite, preferably, comprising 10 to 40wt% of vermiculite is used. The refilling material has a high water hold out barrier performance of bentonite and a high radioactive nuclide adsorbing performance of vermiculite. In a state of highly ionized state when the adsorbing performance of bentonite is reduced, the nuclide-absorbing performance is improved by vermiculite and since the content of the vermiculite is not more than 40wt%, the water hold out barrier performance of the bentonite is not deteriorated. (N.H.)

  10. Ecology, fish and fishery of Lake Liambezi, a recently refilled ...

    African Journals Online (AJOL)

    Lake Liambezi (300 km2) refilled in 2009 after a prolonged 22-year dry period. Its aquatic macrophyte populations, fish fauna and fishery shortly after refilling are described. The emergent aquatic macrophyte Phragmites australis formed dense stands covering large parts of the lake, while extensive beds of submerged ...

  11. Uptake of water via branches helps timberline conifers refill embolized xylem in late winter.

    Science.gov (United States)

    Mayr, Stefan; Schmid, Peter; Laur, Joan; Rosner, Sabine; Charra-Vaskou, Katline; Dämon, Birgit; Hacke, Uwe G

    2014-04-01

    Xylem embolism is a limiting factor for woody species worldwide. Conifers at the alpine timberline are exposed to drought and freeze-thaw stress during winter, which induce potentially lethal embolism. Previous studies indicated that timberline trees survive by xylem refilling. In this study on Picea abies, refilling was monitored during winter and spring seasons and analyzed in the laboratory and in situ experiments, based on hydraulic, anatomical, and histochemical methods. Refilling started in late winter, when the soil was frozen and soil water not available for the trees. Xylem embolism caused up to 86.2% ± 3.1% loss of conductivity and was correlated with the ratio of closed pits. Refilling of xylem as well as recovery in shoot conductance started in February and corresponded with starch accumulation in secondary phloem and in the mesophyll of needles, where we also observed increasing aquaporin densities in the phloem and endodermis. This indicates that active, cellular processes play a role for refilling even under winter conditions. As demonstrated by our experiments, water for refilling was thereby taken up via the branches, likely by foliar water uptake. Our results suggest that refilling is based on water shifts to embolized tracheids via intact xylem, phloem, and parenchyma, whereby aquaporins reduce resistances along the symplastic pathway and aspirated pits facilitate isolation of refilling tracheids. Refilling must be taken into account as a key process in plant hydraulics and in estimating future effects of climate change on forests and alpine tree ecosystems.

  12. Par Pond phytoplankton in association with refilling of the pond: Final Report for sampling from February 1995 -- September 1996

    International Nuclear Information System (INIS)

    Wilde, E.W.; Johnson, M.A.; Cody, W.C.

    1996-01-01

    This report describes the results of phytoplankton analyses from Par Pond samples collected between February 1995 and September 1996. The principal objective of the study was to determine the effect of refilling of Par Pond following repair of the dam on the phytoplankton community. Algal blooms are often responsible for fish kills and other detrimental effects in ponds and lakes, and it was postulated that decaying vegetation from formerly exposed sediments might trigger algal blooms that could result in fish kills in Par Pond following the refill. Sporadic algal blooms involving blue-green algae were detected, especially during the summer of 1996. However, the data derived from the study demonstrates that overall, the refilling effort caused no significant negative impact to the pond attributable to phytoplankton dynamics

  13. Par Pond phytoplankton in association with refilling of the pond: Final Report for sampling from February 1995 -- September 1996

    Energy Technology Data Exchange (ETDEWEB)

    Wilde, E.W.; Johnson, M.A.; Cody, W.C.

    1996-12-31

    This report describes the results of phytoplankton analyses from Par Pond samples collected between February 1995 and September 1996. The principal objective of the study was to determine the effect of refilling of Par Pond following repair of the dam on the phytoplankton community. Algal blooms are often responsible for fish kills and other detrimental effects in ponds and lakes, and it was postulated that decaying vegetation from formerly exposed sediments might trigger algal blooms that could result in fish kills in Par Pond following the refill. Sporadic algal blooms involving blue-green algae were detected, especially during the summer of 1996. However, the data derived from the study demonstrates that overall, the refilling effort caused no significant negative impact to the pond attributable to phytoplankton dynamics.

  14. Changes in spherical aberration after lens refilling with a silicone oil

    NARCIS (Netherlands)

    Wong, Kwok-Hoi; Koopmans, Steven A.; Terwee, Thom; Kooijman, Aart C.

    PURPOSE. It may be possible to restore accommodation to presbyopic human eyes by refilling the lens capsular bag with a soft polymer. In the present study, optical changes were measured that occurred in a pig eye model after the refilling of the capsular bag. METHODS. The optical power and spherical

  15. The endoplasmic reticulum, not the pH gradient, drives calcium refilling of lysosomes

    Science.gov (United States)

    Garrity, Abigail G; Wang, Wuyang; Collier, Crystal MD; Levey, Sara A; Gao, Qiong; Xu, Haoxing

    2016-01-01

    Impaired homeostasis of lysosomal Ca2+ causes lysosome dysfunction and lysosomal storage diseases (LSDs), but the mechanisms by which lysosomes acquire and refill Ca2+ are not known. We developed a physiological assay to monitor lysosomal Ca2+ store refilling using specific activators of lysosomal Ca2+ channels to repeatedly induce lysosomal Ca2+ release. In contrast to the prevailing view that lysosomal acidification drives Ca2+ into the lysosome, inhibiting the V-ATPase H+ pump did not prevent Ca2+ refilling. Instead, pharmacological depletion or chelation of Endoplasmic Reticulum (ER) Ca2+ prevented lysosomal Ca2+ stores from refilling. More specifically, antagonists of ER IP3 receptors (IP3Rs) rapidly and completely blocked Ca2+ refilling of lysosomes, but not in cells lacking IP3Rs. Furthermore, reducing ER Ca2+ or blocking IP3Rs caused a dramatic LSD-like lysosome storage phenotype. By closely apposing each other, the ER may serve as a direct and primary source of Ca2+for the lysosome. DOI: http://dx.doi.org/10.7554/eLife.15887.001 PMID:27213518

  16. Refilling the plasmasphere through the exospheric sieve

    Science.gov (United States)

    Krall, J.; Huba, J.; Emmert, J. T.

    2016-12-01

    The ability to compute plasmasphere densities is critical to many space weather concerns. The sensitivity of refilling to the solar cycle is compelling because, paradoxically, refilling rates are generally lowest when the ionosphere is strongest. In the past, this has been attributed to a dearth of exosphere H at solar maximum. While H is needed to supply H + O+ -> H+ + O charge exchange, recent work demonstrates a significant sensitivity to O [1]. Results will be based on preliminary model-data comparisons using in situ Van Allen Probe EMFISIS data and the SAMI3 ionosphere/plasmasphere code. We will assess the impact of atmospheric composition (i.e., O and H) and solar activity (e.g., F10.7) on plasmasphere refilling rates and density following magnetic storms. SAMI3 (Sami3 is Also a Model of the Ionosphere) is a first-principles ionosphere/plasmasphere model. SAMI3 includes 7 ion species (H+, He+, O+, N+, O2+, N2+, NO+), each treated as a separate fluid, with temperature equations being solved for H+, He+, O+ and e- [2]. SAMI3 uses the empirical MSIS thermosphere/exosphere model to specify O and H densities. SAMI3 includes scaling factors that can be used to tune MSIS densities to bring them in line with measurements of satellite drag. Key inputs for this data-driven modeling are the thermosphere oxygen (O) and hydrogen (H) densities, and the F10.7 proxy for solar ultraviolet irradiance. [1 ]Krall, J., J. T. Emmert, F. Sassi, S. E. McDonald, and J. D. Huba (2016), Day-to-day variability in the thermosphere and its impact on plasmasphere refilling, J. Geophys. Res. Space Physics, 121, doi:10.1002/2015JA022328. [2] Huba, J. and J. Krall (2013), Modeling the plasmasphere with SAMI3, Geophys. Res. Lett., 40, 6-10, doi:10.1029/2012GL054300 Research supported by NRL base funds.

  17. Bacterial hand contamination and transfer after use of contaminated bulk-soap-refillable dispensers.

    Science.gov (United States)

    Zapka, Carrie A; Campbell, Esther J; Maxwell, Sheri L; Gerba, Charles P; Dolan, Michael J; Arbogast, James W; Macinga, David R

    2011-05-01

    Bulk-soap-refillable dispensers are prone to extrinsic bacterial contamination, and recent studies demonstrated that approximately one in four dispensers in public restrooms are contaminated. The purpose of this study was to quantify bacterial hand contamination and transfer after use of contaminated soap under controlled laboratory and in-use conditions in a community setting. Under laboratory conditions using liquid soap experimentally contaminated with 7.51 log(10) CFU/ml of Serratia marcescens, an average of 5.28 log(10) CFU remained on each hand after washing, and 2.23 log(10) CFU was transferred to an agar surface. In an elementary-school-based field study, Gram-negative bacteria on the hands of students and staff increased by 1.42 log(10) CFU per hand (26-fold) after washing with soap from contaminated bulk-soap-refillable dispensers. In contrast, washing with soap from dispensers with sealed refills significantly reduced bacteria on hands by 0.30 log(10) CFU per hand (2-fold). Additionally, the mean number of Gram-negative bacteria transferred to surfaces after washing with soap from dispensers with sealed-soap refills (0.06 log(10) CFU) was significantly lower than the mean number after washing with contaminated bulk-soap-refillable dispensers (0.74 log(10) CFU; P soap (P soap from bulk-soap-refillable dispensers can increase the number of opportunistic pathogens on the hands and may play a role in the transmission of bacteria in public settings.

  18. Uptake of water via branches helps timberline conifers refill embolized xylem in late winter

    OpenAIRE

    Schmid, Peter; Laur, Joan; Rosner, Sabine; Charra-Vaskou, Katline; Daemon, Birgit; Hacke, Uwe G.

    2014-01-01

    Xylem embolism is a limiting factor for woody species worldwide. Conifers at the alpine timberline are exposed to drought and freeze-thaw stress during winter, which induce potentially lethal embolism. Previous studies indicated that timberline trees survive by xylem refilling. In this study on Picea abies, refilling was monitored during winter and spring seasons and analyzed in the laboratory and in situ experiments, based on hydraulic, anatomical, and histochemical methods. Refilling starte...

  19. Bacterial Hand Contamination and Transfer after Use of Contaminated Bulk-Soap-Refillable Dispensers▿†

    Science.gov (United States)

    Zapka, Carrie A.; Campbell, Esther J.; Maxwell, Sheri L.; Gerba, Charles P.; Dolan, Michael J.; Arbogast, James W.; Macinga, David R.

    2011-01-01

    Bulk-soap-refillable dispensers are prone to extrinsic bacterial contamination, and recent studies demonstrated that approximately one in four dispensers in public restrooms are contaminated. The purpose of this study was to quantify bacterial hand contamination and transfer after use of contaminated soap under controlled laboratory and in-use conditions in a community setting. Under laboratory conditions using liquid soap experimentally contaminated with 7.51 log10 CFU/ml of Serratia marcescens, an average of 5.28 log10 CFU remained on each hand after washing, and 2.23 log10 CFU was transferred to an agar surface. In an elementary-school-based field study, Gram-negative bacteria on the hands of students and staff increased by 1.42 log10 CFU per hand (26-fold) after washing with soap from contaminated bulk-soap-refillable dispensers. In contrast, washing with soap from dispensers with sealed refills significantly reduced bacteria on hands by 0.30 log10 CFU per hand (2-fold). Additionally, the mean number of Gram-negative bacteria transferred to surfaces after washing with soap from dispensers with sealed-soap refills (0.06 log10 CFU) was significantly lower than the mean number after washing with contaminated bulk-soap-refillable dispensers (0.74 log10 CFU; P soap (P soap from bulk-soap-refillable dispensers can increase the number of opportunistic pathogens on the hands and may play a role in the transmission of bacteria in public settings. PMID:21421792

  20. Prediction of LOFT core fluid conditions during blowdown and refill

    International Nuclear Information System (INIS)

    Grush, W.H.; White, J.R.

    1978-01-01

    One of the primary objectives of the LOFT (Loss-of-Fluid Test) Program is to provide data required to evaluate and improve the analytical methods currently used to predict the LOCA (Loss-of-Coolant Accident) response of large pressurized water reactors. The purpose of the paper is to describe the computer modeling methods used in predicting the fluid conditions in the LOFT core during the blowdown and refill phases of a nuclear LOCE (Loss-of-Coolant Experiment). Prediction results for a LOFT nonnuclear isothermal LOCE are compared to the experimental data to illustrate the validity of the modeling choices

  1. Improving Refill Adherence in Medicare Patients With Tailored and Interactive Mobile Text Messaging: Pilot Study

    Science.gov (United States)

    Jeong, Erwin W; Feger, Erin; Noble, Harmony K; Kmiec, Magdalen; Prayaga, Ram S

    2018-01-01

    Background Nonadherence is a major concern in the management of chronic conditions such as hypertension, cardiovascular disease, and diabetes where patients may discontinue or interrupt their medication for a variety of reasons. Text message reminders have been used to improve adherence. However, few programs or studies have explored the benefits of text messaging with older populations and at scale. In this paper, we present a program design using tailored and interactive text messaging to improve refill rates of partially adherent or nonadherent Medicare members of a large integrated health plan. Objective The aim of this 3-month program was to gain an understanding of whether tailored interactive text message dialogues could be used to improve medication refills in Medicare patients with one or more chronic diseases. Methods We used the mPulse Mobile interactive text messaging solution with partially adherent and nonadherent Medicare patients (ie, over age 65 years or younger with disabilities) of Kaiser Permanente Southern California (KP), a large integrated health plan, and compared refill rates of the text messaging group (n=12,272) to a group of partially adherent or nonadherent Medicare patients at KP who did not receive text messages (nontext messaging group, n=76,068). Both groups were exposed to other forms of refill and adherence outreach including phone calls, secure emails, and robo-calls from December 2016 to February 2017. Results The text messaging group and nontext messaging group were compared using an independent samples t test to test difference in group average of refill rates. There was a significant difference in medication refill rates between the 2 groups, with a 14.07 percentage points higher refill rate in the text messaging group (Pimprove medication refill rates among Medicare patients. These findings also support using interactive text messaging as a cost-effective, convenient, and user-friendly solution for patient engagement

  2. Clinic Attendance for Medication Refills and Medication Adherence amongst an Antiretroviral Treatment Cohort in Uganda: A Prospective Study

    Directory of Open Access Journals (Sweden)

    Setor Kunutsor

    2010-01-01

    Full Text Available Background. Regular clinic attendance for antiretroviral (ARV drug refills is important for successful clinical outcomes in HIV management. Methods. Clinic attendance for ARV drug refills and medication adherence using a clinic-based pill count in 392 adult patients receiving antiretroviral therapy (ART in a district hospital in Uganda were prospectively monitored over a 28-week period. Results. Of the 2267 total scheduled clinic visits, 40 (1.8% were missed visits. Among the 392 clients, 361 (92% attended all appointments for their refills (regular attendance. Clinic attendance for refills was statistically significantly associated with medication adherence with regular attendant clients having about fourfold greater odds of achieving optimal (≥95% medication adherence [odds ratio (OR=3.89, 95% CI: 1.48 to 10.25, exact P=.013]. In multivariate analysis, clients in age category 35 years and below were less likely to achieve regular clinic attendance. Conclusion. Monitoring of clinic attendance may be an objective and effective measure and could be a useful adjunct to an adherence measure such as pill counting in resource-constrained settings. Where human resource constraints do not allow pill counts or other time-consuming measures, then monitoring clinic attendance and acting on missed appointments may be an effective proxy measure.

  3. 21 CFR 1306.22 - Refilling of prescriptions.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Refilling of prescriptions. 1306.22 Section 1306.22 Food and Drugs DRUG ENFORCEMENT ADMINISTRATION, DEPARTMENT OF JUSTICE PRESCRIPTIONS Controlled... 75 FR 16308, Mar. 31, 2010, § 1306.22 was revised, effective June 1, 2010. For the convenience of the...

  4. Par Pond refill water quality sampling

    International Nuclear Information System (INIS)

    Koch, J.W. II; Martin, F.D.; Westbury, H.M.

    1996-08-01

    This study was designed to document anoxia and its cause in the event that the anoxia caused a fish kill. However, no fish kill was observed during this study, and dissolved oxygen and nutrient concentrations generally remained within the range expected for southeastern reservoirs. Par Pond water quality monitoring will continue during the second summer after refill as the aquatic macrophytes become reestablished and nutrients in the sediments are released to the water column

  5. Respiratory failure following delayed intrathecal morphine pump refill: a valuable, but costly lesson.

    Science.gov (United States)

    Ruan, Xiulu; Couch, J Patrick; Liu, HaiNan; Shah, Rinoo V; Wang, Frank; Chiravuri, Srinivas

    2010-01-01

    Spinal analgesia, mediated by opioid receptors, requires only a fraction of the opioid dose that is needed systemically. By infusing a small amount of opioid into the cerebrospinal fluid in close proximity to the receptor sites in the spinal cord, profound analgesia may be achieved while sparing some of the side effects due to systemic opioids. Intraspinal drug delivery (IDD) has been increasingly used in patients with intractable chronic pain, when these patients have developed untoward side effects with systemic opioid usage. The introduction of intrathecal opioids has been considered one of the most important breakthroughs in pain management in the past three decades. A variety of side effects associated with the long-term usage of IDD have been recognized. Among them, respiratory depression is the most feared. To describe a severe adverse event, i.e., respiratory failure, following delayed intrathecal morphine pump refill. A 65-year-old woman with intractable chronic low back pain, due to degenerative disc disease, and was referred to our clinic for an intraspinal drug delivery evaluation, after failing to respond to multidisciplinary pain treatment. Following a psychological evaluation confirming her candidacy, she underwent an outpatient patient-controlled continuous epidural morphine infusion trial. The infusion trial lasted 12 days and was beneficial in controlling her pain. The patient reported more than 90% pain reduction with improved distance for ambulation. She subsequently consented and was scheduled for permanent intrathecal morphine pump implantation. The intrathecal catheter was inserted at right paramedian L3-L4, with catheter tip advanced to L1, confirmed under fluoroscopy. Intrathecal catheter placement was confirmed by positive CSF flow and by myelogram. A non-programmable Codman 3000 constant-flow rate infusion pump was placed in the right mid quandrant between right rib cage and right iliac crest. The intrathecal infusion consisted of

  6. Refillable and magnetically actuated drug delivery system using pear-shaped viscoelastic membrane

    KAUST Repository

    So, Hongyun

    2014-07-01

    We report a refillable and valveless drug delivery device actuated by an external magnetic field for on-demand drug release to treat localized diseases. The device features a pear-shaped viscoelastic magnetic membrane inducing asymmetrical deflection and consecutive touchdown motion to the bottom of the dome-shaped drug reservoir in response to a magnetic field, thus achieving controlled discharge of the drug. Maximum drug release with 18 ± 1.5 μg per actuation was achieved under a 500 mT magnetic flux density, and various controlled drug doses were investigated with the combination of the number of accumulated actuations and the strength of the magnetic field.

  7. A Digital Language Divide? The Relationship between Internet Medication Refills and Medication Adherence among Limited English Proficient (LEP) Patients.

    Science.gov (United States)

    Casillas, Alejandra; Moreno, Gerardo; Grotts, Jonathan; Tseng, Chi-Hong; Morales, Leo S

    2018-03-29

    Use of an Internet portal to refill medicines positively affects medication adherence among English-speakers. No prior studies, however, have specifically examined the relationship between Internet refills and medication adherence among patients who are limited English proficient (LEP). (1) Examine the relationship between Internet medication refill system use and medication adherence among linguistically diverse patients with chronic conditions and (2) compare this relationship between LEP and English-proficient (EP) patients. We analyzed 2013-2014 cross-sectional data from 509 surveyed adults in the Group Health Cooperative. Surveys were merged with plan enrollment, claims data, and electronic medical records. Medication adherence was calculated by the "Continuous Measure of Medication Gaps" (CMG) method. For Internet refill system use, patients were asked, "Have you used the health systems Internet site to refill any medications in the last 12 months?" LEP status was captured in the electronic medical record by a non-English primary language and a claims record of interpreter use in at least one clinical encounter between 2005 and 2012. We used multivariate linear regression models to examine Internet refill system use and medication adherence and compared the association between LEP and EP patients. Three hundred eighty-four patients (75%) had a calculable CMG: 134 EP and 250 LEP in the adherence analyses. In unadjusted analyses, LEP patients had lower use of the Internet refill system (p < .001) and lower adherence versus the EP group (p < .001). In multivariate analyses, LEP status (β = - 0.022, p = .047) was negatively associated with adherence, while use of the Internet refill system (β = 0.030, p = .002) was positively associated. In stratified models, use of Internet refills was positively associated with adherence, even when examining LEP (β = 0.029, p = .003) and EP patients (β = 0.027, p = .049) separately

  8. BWR Refill-Reflood Program, Task 4.7 - model development: TRAC-BWR component models

    International Nuclear Information System (INIS)

    Cheung, Y.K.; Parameswaran, V.; Shaug, J.C.

    1983-09-01

    TRAC (Transient Reactor Analysis Code) is a computer code for best-estimate analysis for the thermal hydraulic conditions in a reactor system. The development and assessment of the BWR component models developed under the Refill/Reflood Program that are necessary to structure a BWR-version of TRAC are described in this report. These component models are the jet pump, steam separator, steam dryer, two-phase level tracking model, and upper-plenum mixing model. These models have been implemented into TRAC-B02. Also a single-channel option has been developed for individual fuel-channel analysis following a system-response calculation

  9. Short- and long-term effects of real-time medication monitoring with short message service (SMS) reminders for missed doses on the refill adherence of people with Type 2 diabetes: evidence from a randomised controlled trial.

    NARCIS (Netherlands)

    Vervloet, M.; Dijk, L. van; Bakker, D.H. de; Souverein, P.C.; Santen-Reestman, J.; Vlijmen, B. van; Aarle, M.C.W. van; Hoek, L.S. van der; Bouvy, M.L.

    2014-01-01

    Aims: To investigate short- and long-term effects of real-time monitoring medication use combined with short message service (SMS) reminders for missed doses on refill adherence to oral anti-diabetic medication. Methods: A randomized controlled trial with two intervention groups and one control

  10. Detection and quantitative determination of heavy metals in electronic cigarette refill liquids using Total Reflection X-ray Fluorescence Spectrometry.

    Science.gov (United States)

    Kamilari, Eleni; Farsalinos, Konstantinos; Poulas, Konstantinos; Kontoyannis, Christos G; Orkoula, Malvina G

    2018-06-01

    Electronic cigarettes are considered healthier alternatives to conventional cigarettes containing tobacco. They produce vapor through heating of the refill liquids (e-liquids) which consist of propylene glycol, vegetable glycerin, nicotine (in various concentrations), water and flavoring agents. Heavy metals may enter the refill liquid during the production, posing a risk for consumer's health due to their toxicity. The objective of the present study was the development of a methodology for the detection and quantitative analysis of cadmium (Cd), lead (Pb), nickel (Ni), copper (Cu), arsenic (As) and chromium (Cr), employing Total Reflection X-Ray Fluorescence Spectroscopy (TXRF) as an alternative technique to ICP-MS or ICP-OES commonly used for this type of analysis. TXRF was chosen due to its advantages, which include short analysis time, promptness, simultaneous multi-element analysis capability and minimum sample preparation, low purchase and operational cost. The proposed methodology was applied to a large number of electronic cigarette liquids commercially available, as well as their constituents, in order to evaluate their safety. TXRF may be a valuable tool for probing heavy metals in electronic cigarette refill liquids to serve for the protection of human health. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. ALGORITHM OF DETERMINATION OF POWER AND ENERGY INDEXES OF SCREW INTENSIFIER ON THE BULLDOZER WORKING EQUIPMENT AT TRENCH REFILLINGS

    Directory of Open Access Journals (Sweden)

    KROL R. N.

    2016-03-01

    Full Text Available Raising of problem. A bulldozer work at trench refilings is conducted by cyclic, machine shuttle motions that increases a right-of-way; increasing of time charges, fuel and labour by the side of the continuous refilling method. Besides the indicated defects gets worse also the quality of the trench refilling: the uneven soil output into a trench with large portions results the damages of pipes isolation and emptinesses formation, in consequence  settling and washing of soil. A bulldozer with the screw intensifier (SI, is deprived lacks of an odinary bulldozer  moving along a trench, it moves the loose soil that does not fall on a pipeline, but rolles on it. Thus the circuitous speed of a cutting edge of SI exceeds the speed of the base machine moving that provides the strong soil treatment (before dispersion before output into a trench. Purpose. The algorithm development of the rotational moment determination on the SI driveshaft, the consumable energy, the energy intensity and the working process productivity of the reverse trench refillings depending on physical and mechanical properties of soil, geometrical parameters of SI and bulldozer optimal speed. Conclusion. The developed algorithm allows to define that at the fixed value of the rotational speed the rotational moment and indicated efficiency of SI at the optimum speed increasing of the base machine change on a linear law; the optimum speed change of the base machine practically does not influence on the energy intensity at the considered change of the rotational speed .

  12. Theoretical Study on the Flow of Refilling Stage in a Safety Injection Tank

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jun Sang [Halla Univ. Daejeon (Korea, Republic of)

    2017-10-15

    In this study, a theoretical analysis was performed to the flow of refilling stage in a safety injection tank, which is the core cooling system of nuclear power plant in an emergency. A theoretical model was proposed with a nonlinear governing equation defining on the flow of the refilling process of the coolant. Utilizing the Taylor-series expansion, the 1st - order approximation flow equation was obtained, along with its analytic solution of closed type, which could predict accurately the variations of free surface height and flow rate of the coolant. The availability of theoretical result was confirmed by comparing with previous experimental results.

  13. Bio rapid prototyping by extruding/aspirating/refilling thermoreversible hydrogel

    International Nuclear Information System (INIS)

    Iwami, K; Noda, T; Ishida, K; Umeda, N; Morishima, K; Nakamura, M

    2010-01-01

    This paper reports a method for rapid prototyping of cell tissues, which is based on a system that extrudes, aspirates and refills a mixture of cells and thermoreversible hydrogel as a scaffold. In the extruding mode, a cell-mixed scaffold solution in the sol state is extruded from a cooled micronozzle into a temperature-controlled substrate, which keeps the scaffold in the gel state. In the aspiration mode, the opposite process is performed by Bernoulli suction. In the refilling mode, the solution is extruded into a groove created in the aspiration mode. The minimum width of extruded hydrogel pattern is 114 ± 15 μm by employing a nozzle of diameter 100 μm, and that of aspirated groove was 355 ± 10 μm using a 500 μm-diameter nozzle. Gum arabic is mixed with the scaffold solution to avoid peeling-off of the gel pattern from the substrate. Patterning of Sf-9 cell tissue is demonstrated, and the stability of the patterned cell is investigated. This system offers a procedure for rapid prototyping and local modification of cell scaffolds for tissue engineering.

  14. Refillable and magnetically actuated drug delivery system using pear-shaped viscoelastic membrane

    KAUST Repository

    So, Hongyun; Seo, Young Ho; Pisano, Albert P.

    2014-01-01

    We report a refillable and valveless drug delivery device actuated by an external magnetic field for on-demand drug release to treat localized diseases. The device features a pear-shaped viscoelastic magnetic membrane inducing asymmetrical

  15. Analysis of spatial and temporal dynamics of xylem refilling in Acer rubrum L. using magnetic resonance imaging.

    Science.gov (United States)

    Zwieniecki, Maciej A; Melcher, Peter J; Ahrens, Eric T

    2013-01-01

    We report results of an analysis of embolism formation and subsequent refilling observed in stems of Acer rubrum L. using magnetic resonance imaging (MRI). MRI is one of the very few techniques that can provide direct non-destructive observations of the water content within opaque biological materials at a micrometer resolution. Thus, it has been used to determine temporal dynamics and water distributions within xylem tissue. In this study, we found good agreement between MRI measures of pixel brightness to assess xylem liquid water content and the percent loss in hydraulic conductivity (PLC) in response to water stress (P50 values of 2.51 and 2.70 for MRI and PLC, respectively). These data provide strong support that pixel brightness is well correlated to PLC and can be used as a proxy of PLC even when single vessels cannot be resolved on the image. Pressure induced embolism in moderately stressed plants resulted in initial drop of pixel brightness. This drop was followed by brightness gain over 100 min following pressure application suggesting that plants can restore water content in stem after induced embolism. This recovery was limited only to current-year wood ring; older wood did not show signs of recovery within the length of experiment (16 h). In vivo MRI observations of the xylem of moderately stressed (~-0.5 MPa) A. rubrum stems revealed evidence of a spontaneous embolism formation followed by rapid refilling (~30 min). Spontaneous (not induced) embolism formation was observed only once, despite over 60 h of continuous MRI observations made on several plants. Thus this observation provide evidence for the presence of naturally occurring embolism-refilling cycle in A. rubrum, but it is impossible to infer any conclusions in relation to its frequency in nature.

  16. Comparison of various measures for assessing medication refill adherence using prescription data

    NARCIS (Netherlands)

    Vink, N. M.; Klungel, O. H.; Stolk, R. P.; Denig, P.

    Background Several measures using prescription data have been developed for estimating medication refill adherence. Few Studies have made direct comparisons, and little is known about the accuracy of these measures in patients oil a multiple-drug regimen. Purpose To compare different calculation

  17. A granular refillable filter for glas-flows contaminated by radioactive impurities

    International Nuclear Information System (INIS)

    Bonn, J.W.

    1975-01-01

    Description is given of a granular charcoal refillable filter adapted to adsorb the radioactive impurities of a gaseous flow. That flow comprises a number of filtering layers, the consumed charcoal of which can be discharged by a pneumatic device without exposing the personnel to radioactivity. This can be applied to emergency devices in nuclear facilities [fr

  18. Analysis of spatial and temporal dynamics of xylem refilling in Acer rubrum L. using magnetic resonance imaging (MRI.

    Directory of Open Access Journals (Sweden)

    Maciej Andrzej Zwieniecki

    2013-07-01

    Full Text Available We report results of an analysis of embolism formation and subsequent refilling observed in stems of Acer rubrum L. using magnetic resonance imaging (MRI. MRI is one of the very few techniques that can provide direct non-destructive observations of the water content within opaque biological materials at a micrometer resolution. Thus, it has been used to determine temporal dynamics and water distributions within xylem tissue. In this study, we found good agreement between MRI measures of pixel brightness to assess xylem liquid water content and the percent loss in hydraulic conductivity (PLC in response to water stress (P50 values of 2.51 and 2.70 for MRI and PLC, respectively. These data provide strong support that pixel brightness is well correlated to PLC and can be used as a proxy of PLC even when single vessels cannot be resolved on the image. Pressure induced embolism in moderately stressed plants resulted in initial drop of pixel brightness. This drop was followed by brightness gain over 100 minutes following pressure application suggesting that plants can restore water content in stem after induced embolism. This recovery was limited only to current year wood ring; older wood did not show signs of recovery within the length of experiment (16 hours. In vivo MRI observations of the xylem of moderately stressed (~-0.5 MPa A. rubrum stems revealed evidence of a spontaneous embolism formation followed by rapid refilling (~30 minutes. Spontaneous (not induced embolism formation was observed only once, despite over 60 hours of continuous MRI observations made on several plants. Thus this observation provide evidence for presence of naturally occurring embolism-refilling cycle in A. rubrum, but it is impossible to infer any conclusions in relation to its frequency in nature.

  19. Impact of late-to-refill reminder calls on medication adherence in the Medicare Part D population: evaluation of a randomized controlled study

    Directory of Open Access Journals (Sweden)

    Taitel MS

    2017-02-01

    Full Text Available Michael S Taitel, Ying Mu, Angshuman Gooptu, Youbei Lou Health Analytics, Research & Reporting, Walgreen Co., Deerfield, IL, USA Objectives: This study evaluates a nationwide pharmacy chain’s late-to-refill (LTR reminder program that entails local pharmacists placing reminder calls to Medicare Part D patients. Methods: We conducted a randomized controlled study among 735,218 patients who exhibited nonadherent behavior by not refilling a maintenance medication 3 days from an expected refill date. Patients were randomly assigned to an intervention group who received LTR reminder calls or to a control group. We used Walgreens pharmaceutical claims data from 2015 to estimate the impact of LTR calls on short-term and annual adherence. Results: The initial refill rate within the first 14 days of the expected refill date significantly increased in the intervention group by 22.8% (6.09 percentage points compared to the control group (P<0.001. The proportion of days covered (PDC in the intervention group increased significantly by 1.5% (0.856 percentage points relative to the control group (P<0.001 over 365 days. Patients in the intervention group were significantly more adherent (PDC ≥80% by 3% (0.97 percentage points compared to the control group (P<0.001. Over a 270-day follow-up period, persistence significantly increased by 2.15 days in the intervention group (P<0.001. Conclusion: Results from this study suggest that LTR reminder calls increased adherence for Medicare Part D patients who are late in refilling their medications and therefore have the potential to reduce their risk for hospitalization and health care costs. Additionally, the intervention increased the number of patients with PDC ≥80% by ~3%, positively impacting Medicare Part D plan quality rating. Keywords: reminder system, tailored intervention, Medicare Part D, adherence, persistence

  20. A Parametric Study of the Cold Plasma Refilling Rate on the Plasmasphere and Inner Magnetosphere Dynamics during the 17-March-2013 and 28-June-2013 Magnetic Storms

    Science.gov (United States)

    Lemon, C.; Bishop, R. L.; Coster, A. J.; Nikoukar, R.; Chen, M.; Turner, D. L.; Roeder, J. L.; Shumko, M.; Payne, C.; Bhatt, R.

    2017-12-01

    plasmasphere trough. We compare several empirical models of the plasmasphere refilling rate to see which ones give the best agreement, and through parametric simulations we systematically investigate the effect of varying the local time and L dependence of the refilling rate.

  1. 40 CFR 165.65 - Registrants who distribute or sell pesticide products in refillable containers.

    Science.gov (United States)

    2010-07-01

    ... formula that is required under FIFRA section 3. (c) What information must I develop? For each pesticide... its confidential statement of formula that is required under FIFRA section 3. (ii) If the refilling..., metal fatigue, damaged threads or closures, or other significant defects. (iii) The container has cracks...

  2. CONSUMER SEGMENTATION OF REFILLED DRINKING WATER IN PADANG

    Directory of Open Access Journals (Sweden)

    Awisal Fasyni

    2015-05-01

    Full Text Available The purposes of this study were to analyze consumer segmentation of refilled drinking water based on their behavior and to recommend strategies for increased sales of Salju depot. The study was conducted using a survey of family and non-family consumers in Nanggalo, North Padang, West and East Padang. The respondent selection technique is using a convenience sampling, which is based on the availability of elements and easiness of obtaining these samples. The analysis used for segmentation is cluster analysis and CHAID. The results showed that there were five segments in family consumer and four segments in non-family consumer. Each family segment was different in terms of usage and consumption level, while non-family segments differ in terms of consumption duration and consumption level. Salju depot could aim market segments that provide benefits, specifically segments with high consumption levels both in family and nonfamily consumers, maintain the price and quality of the product and show the best performance in serving customers, set the open hours and optimize the messaging services.Keywords: refilled drinking water, segmentation, Padang, CHAIDABSTRAKPenelitian ini bertujuan menganalisis segmentasi konsumen air minum isi ulang berdasarkan perilakunya dan merekomendasikan strategi peningkatan penjualan bagi depot Salju. Penelitian dilakukan dengan metode survei terhadap konsumen keluarga dan konsumen nonkeluarga di Kecamatan Nanggalo, Kecamatan Padang Utara, Kecamatan Padang Barat dan Kecamatan Padang Timur Kota Padang. Teknik pemilihan responden menggunakan convenience sampling, yaitu berdasarkan ketersediaan elemen dan kemudahan mendapatkan sampel tersebut. Analisis yang digunakan untuk segmentasi adalah analisis cluster dan CHAID Hasil penelitian menunjukkan terdapat lima segmen konsumen keluarga dan empat segmen konsumen nonkeluarga. Masing-masing segmen keluarga berbeda dalam hal penggunaan dan tingkat konsumsi, sedangkan segmen

  3. Psychometric Evaluation of a Korean Version of the Adherence to Refills and Medications Scale (ARMS) in Adults With Type 2 Diabetes.

    Science.gov (United States)

    Kim, Chun-Ja; Park, Eunyoung; Schlenk, Elizabeth A; Kim, Moonsun; Kim, Dae Jung

    2016-04-01

    The purpose of the study was to examine the reliability and validity of the Adherence to Refills and Medications Scale-Korean (ARMS-K) among Korean adults with type 2 diabetes. The Korean translated ARMS-K was back-translated to ensure translation equivalency. A cross-sectional survey was used to evaluate the psychometric properties with exploratory factor analysis for validity and Cronbach's alpha coefficients for reliability. The factor analysis of construct validity identified 3 dimensions of the ARMS-K, explaining 54.7% of the total variance. The internal consistency reliability for the total instrument was acceptable with a Cronbach's alpha of .801. There was good correlation between the ARMS-K and 8-item Morisky Medication Adherence Scale-Korean version (r = -0.698), indicating that these scales measure theoretically related constructs as evidence of convergent validity. As evidence of known groups validity, there was a significant association between the ARMS-K score and glycemic control (P = .048), indicating that the good glycemic controlled group was more likely to have a higher rate of adherence to refills and medications than the poor glycemic controlled group. These results support the cross-cultural applicability of the concepts underlying the ARMS-K. The ARMS-K can be used not only to assess adherence to refills and medications in Koreans with diabetes but also to examine the potential role of adherence to refills and medications in enhanced glycemic control of people with diabetes in a variety of clinical settings. © 2016 The Author(s).

  4. Effect of infusion bottle height on lens power after lens refilling with and without a plug

    NARCIS (Netherlands)

    Koopmans, SA; Terwee, T; Haitjema, HJ; Kooijman, AC; Barkhof, J

    2003-01-01

    Purpose: To evaluate the influence of intraoperative infusion bottle height on the power of refilled pig lenses. Setting: Research Laboratory, Pharmacia Intraocular Lens Manufacturing Plant, Groningen, The Netherlands. Methods: This study comprised 2 groups of pig eyes. In 1 group, the lens was

  5. Optical thermal sensor based on cholesteric film refilled with mixture of toluene and ethanol.

    Science.gov (United States)

    Li, Yong; Liu, Yanjun; Luo, Dan

    2017-10-16

    We demonstrate an optical thermal sensor based on cholesteric film refilled with mixture of toluene and ethanol. The thermal response mechanism is mainly based on the thermal expansion effect induce by toluene, where the ethanol is used for refractive index adjustment to determine the initial refection band position of cholesteric film. The ethanol-toluene mixture was used to adjust the color tunability with the temperature in relation with the habits of people (blue as cold, green as safe and red as hot). A broad temperature range of 86 °C and highly sensitivity of 1.79 nm/ °C are achieved in proposed thermal sensor, where the reflective color red-shifts from blue to red when environmental temperature increases from -6 °C to 80 °C. This battery-free thermal sensor possesses features including simple fabrication, low-cost, and broad temperature sensing range, showing potential application in scientific research and industry.

  6. Phytoremediation of arsenic-contaminated groundwater using arsenic hyperaccumulator Pteris vittata L.: effects of frond harvesting regimes and arsenic levels in refill water.

    Science.gov (United States)

    Natarajan, Seenivasan; Stamps, Robert H; Ma, Lena Q; Saha, Uttam K; Hernandez, Damaris; Cai, Yong; Zillioux, Edward J

    2011-01-30

    A large-scale hydroponic system to phytoremediate arsenic-contaminated groundwater using Pteris vittata (Chinese brake fern) was successfully tested in a field. In this 30-wk study, three frond-harvesting regimes (all, mature, and senescing fronds) and two water-refilling schemes to compensate for evapotranspiration (high-As water of 140-180 μg/L and low-As water of arsenic-contaminated groundwater and 32 ferns. During Cycle 1 and with initial As of 140 μg/L, As in tanks refilled with low-As water was reduced to phytoremediation. Published by Elsevier B.V.

  7. Adherence to On-Time ART Drug Pick-Up and Its Association with CD4 Changes and Clinical Outcomes Amongst HIV Infected Adults on First-Line Antiretroviral Therapy in Nigerian Hospitals.

    Science.gov (United States)

    Anoje, Chukwuemeka; Agu, Kenneth Anene; Oladele, Edward A; Badru, Titilope; Adedokun, Oluwasanmi; Oqua, Dorothy; Khamofu, Hadiza; Adebayo, Olufunso; Torpey, Kwasi; Chabikuli, Otto Nzapfurundi

    2017-02-01

    Medication adherence is a major determinant of antiretroviral treatment (ART) success. Promptness in medication refill pick-ups may give an indication of medication adherence. This study determined medication refill adherence among HIV positive patients on ART and its association with treatment outcomes in HIV treatment centers in Nigeria. This retrospective multi-center cohort study involved a review of ART refill records for 3534 HIV-positive patients aged 18-60 years who initiated first-line ART between January 2008 and December 2009 and were on therapy for ≥18 months after ART initiation. Drug refill records of these patients for 10 consecutive refill visits after ART initiation were analyzed. The first ten consecutive refill appointment-keeping rates after ART initiation ranged from 64.3 % to 76.1 % which decreased with successive visits. Altogether, 743 (21.1 %) patients were deemed adherent, meaning they picked up their drugs within 7 days of the drug refill appointment date on at least nine out of ten refill visits. The adherent group of patients had a mean CD4 cells increase of 206 ± 6.1 cells/dl after 12 months of ART compared to 186 ± 7.1 cells/dl reported among the nonadherent group (p = 0.0145). The proportion of patients in the adherent category who showed no OIs after 12 months on ART (81 %) was significantly higher when compared to the proportion in the non-adherent category (23.5 %), (p = 0.008). The multivariate analysis showed that the odds of being adherent was 2-3 times more in patients who had a baseline CD4 count of less than 200 cells/dl compared to those with a baseline CD4 of >350 cells/dl. (AOR 2.43, 95 % CI 1.62-3.66). In addition, for patients with baseline CD4 cell count of 201-350 cells/dl, the odds of being adherent was found to be 1.9 compared to those with baseline CD4 of greater than 350 cells/dl (AOR 1.93, 95 % CI 1.27-2.94). Pharmacy refill data can serve as an adherence measure. Adherence to on-time drug

  8. Structures of Bordered Pits Potentially Contributing to Isolation of a Refilled Vessel from Negative Xylem Pressure in Stems of Morus australis Poir.: Testing of the Pit Membrane Osmosis and Pit Valve Hypotheses.

    Science.gov (United States)

    Ooeda, Hiroki; Terashima, Ichiro; Taneda, Haruhiko

    2017-02-01

    Two hypotheses have been proposed to explain the mechanism preventing the refilling vessel water from being drained to the neighboring functional vessels under negative pressure. The pit membrane osmosis hypothesis proposes that the xylem parenchyma cells release polysaccharides that are impermeable to the intervessel pit membranes into the refilling vessel; this osmotically counteracts the negative pressure, thereby allowing the vessel to refill. The pit valve hypothesis proposes that gas trapped within intervessel bordered pits isolates the refilling vessel water from the surrounding functional vessels. Here, using the single-vessel method, we assessed these hypotheses in shoots of mulberry (Morus australis Poir.). First, we confirmed the occurrence of xylem refilling under negative pressure in the potted mulberry saplings. To examine the pit membrane osmosis hypothesis, we estimated the semi-permeability of pit membranes for molecules of various sizes and found that the pit membranes were not semi-permeable to polyethylene glycol of molecular mass osmosis mechanism in mulberry would be unrealistically large. © The Author 2016. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  9. Bacterial Hand Contamination and Transfer after Use of Contaminated Bulk-Soap-Refillable Dispensers▿†

    OpenAIRE

    Zapka, Carrie A.; Campbell, Esther J.; Maxwell, Sheri L.; Gerba, Charles P.; Dolan, Michael J.; Arbogast, James W.; Macinga, David R.

    2011-01-01

    Bulk-soap-refillable dispensers are prone to extrinsic bacterial contamination, and recent studies demonstrated that approximately one in four dispensers in public restrooms are contaminated. The purpose of this study was to quantify bacterial hand contamination and transfer after use of contaminated soap under controlled laboratory and in-use conditions in a community setting. Under laboratory conditions using liquid soap experimentally contaminated with 7.51 log10 CFU/ml of Serratia marcesc...

  10. Pharmacy refill adherence compared with CD4 count changes for monitoring HIV-infected adults on antiretroviral therapy.

    Directory of Open Access Journals (Sweden)

    Gregory P Bisson

    2008-05-01

    Full Text Available World Health Organization (WHO guidelines for monitoring HIV-infected individuals taking combination antiretroviral therapy (cART in resource-limited settings recommend using CD4(+ T cell (CD4 count changes to monitor treatment effectiveness. In practice, however, falling CD4 counts are a consequence, rather than a cause, of virologic failure. Adherence lapses precede virologic failure and, unlike CD4 counts, data on adherence are immediately available to all clinics dispensing cART. However, the accuracy of adherence assessments for predicting future or detecting current virologic failure has not been determined. The goal of this study therefore was to determine the accuracy of adherence assessments for predicting and detecting virologic failure and to compare the accuracy of adherence-based monitoring approaches with approaches monitoring CD4 count changes.We conducted an observational cohort study among 1,982 of 4,984 (40% HIV-infected adults initiating non-nucleoside reverse transcriptase inhibitor-based cART in the Aid for AIDS Disease Management Program, which serves nine countries in southern Africa. Pharmacy refill adherence was calculated as the number of months of cART claims submitted divided by the number of complete months between cART initiation and the last refill prior to the endpoint of interest, expressed as a percentage. The main outcome measure was virologic failure defined as a viral load > 1,000 copies/ml (1 at an initial assessment either 6 or 12 mo after cART initiation and (2 after a previous undetectable (i.e., 0.5. In addition, adherence levels assessed 3 mo prior to viral load assessments were as accurate for virologic failure occurring approximately 3 mo later as were CD4 count changes calculated from cART initiation to the actual time of the viral load assessments, indicating the potential utility of adherence assessments for predicting future, rather than simply detecting current, virologic failure. Moreover

  11. Compact and Robust Refilling and Connectorization of Hollow Core Photonic Crystal Fiber Gas Reference Cells

    Science.gov (United States)

    Poberezhskiy, Ilya Y.; Meras, Patrick; Chang, Daniel H.; Spiers, Gary D.

    2007-01-01

    This slide presentation reviews a method for refilling and connectorization of hollow core photonic crystal fiber gas reference cells. Thees hollow-core photonic crystal fiber allow optical propagation in air or vacuum and are for use as gas reference cell is proposed and demonstrated. It relies on torch-sealing a quartz filling tube connected to a mechanical splice between regular and hollow-core fibers.

  12. Failure to refill essential prescription medications for asthma among pediatric Medicaid beneficiaries with persistent asthma

    Directory of Open Access Journals (Sweden)

    Vaidya V

    2013-01-01

    Full Text Available Varun Vaidya,1 Renuka Gupte,2 Rajesh Balkrishnan31Pharmacy Health Care Administration, Department of Pharmacy Practice, University of Toledo College of Pharmacy, Toledo, OH, USA; 2Private Practice, Sylvania, OH, USA; 3Department of Clinical, Social and Administrative Sciences, Pharmacy, The University of Michigan, Ann Arbor, MI, USAAbstract: The problem of patients not taking medications as prescribed, also known as "lack of medication adherence," is widely discussed as an issue related to suboptimal outcomes and excess health care expenditure. Although medication adherence is defined as patients not taking medications as prescribed, there are two elements to it: first, those who fail to follow the medication regimen by skipping a dose or not following the instructions, resulting in poor adherence with prescribed medicines; and, second, the patient who does not take the medication at all or stops after the initial fill. The existing literature contains a lot of studies on the first element, but very little is known about those who stop taking their medication after the initial fill or do not take it at all. In this study, our focus is on identifying patients who fail to refill a prescription for essential medicines, such as asthma-controlling drugs. Using Medicaid claims datasets, this study analyzed a pediatric population diagnosed with persistent asthma that discontinued an essential controlling medication after the initial fill. We found that more than half of this population did not continue their medication after the first fill. While there might be many reasons behind the failure to refill such medications, our data indicate that race/ethnicity, comorbid illness, and type of Medicaid plan are potentially associated with such behavior. Future research is warranted to understand this issue further and identify specific factors causing such behavior, such that strategies may be formulated by which poor adherence can be minimized

  13. The Power of Flash Mob Research: Conducting a Nationwide Observational Clinical Study on Capillary Refill Time in a Single Day.

    Science.gov (United States)

    Alsma, Jelmer; van Saase, Jan L C M; Nanayakkara, Prabath W B; Schouten, W E M Ineke; Baten, Anique; Bauer, Martijn P; Holleman, Frits; Ligtenberg, Jack J M; Stassen, Patricia M; Kaasjager, Karin H A H; Haak, Harm R; Bosch, Frank H; Schuit, Stephanie C E

    2017-05-01

    Capillary refill time (CRT) is a clinical test used to evaluate the circulatory status of patients; various methods are available to assess CRT. Conventional clinical research often demands large numbers of patients, making it costly, labor-intensive, and time-consuming. We studied the interobserver agreement on CRT in a nationwide study by using a novel method of research called flash mob research (FMR). Physicians in the Netherlands were recruited by using word-of-mouth referrals, conventional media, and social media to participate in a nationwide, single-day, "nine-to-five," multicenter, cross-sectional, observational study to evaluate CRT. Patients aged ≥ 18 years presenting to the ED or who were hospitalized were eligible for inclusion. CRT was measured independently (by two investigators) at the patient's sternum and distal phalanx after application of pressure for 5 s (5s) and 15 s (15s). On October 29, 2014, a total of 458 investigators in 38 Dutch hospitals enrolled 1,734 patients. The mean CRT measured at the distal phalanx were 2.3 s (5s, SD 1.1) and 2.4 s (15s, SD 1.3). The mean CRT measured at the sternum was 2.6 s (5s, SD 1.1) and 2.7 s (15s, SD 1.1). Interobserver agreement was higher for the distal phalanx (κ value, 0.40) than for the sternum (κ value, 0.30). Interobserver agreement on CRT is, at best, moderate. CRT measured at the distal phalanx yielded higher interobserver agreement compared with sternal CRT measurements. FMR proved a valuable instrument to investigate a relatively simple clinical question in an inexpensive, quick, and reliable manner. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  14. Impact of electronic-cigarette refill liquid on rat testis.

    Science.gov (United States)

    El Golli, N; Rahali, D; Jrad-Lamine, A; Dallagi, Y; Jallouli, M; Bdiri, Y; Ba, N; Lebret, M; Rosa, J P; El May, M; El Fazaa, S

    2016-07-01

    Electronic cigarettes (e-cigarettes) are becoming the fashionable alternative to decrease tobacco smoking, although their impact on health has not been fully assessed yet. The present study was designed to compare the impact of e-cigarette refill liquid (e-liquid) without nicotine to e-liquid with nicotine on rat testis. For this purpose, e-liquid with nicotine and e-liquid without nicotine (0.5 mg/kg of body weight) were administered to adult male Wistar rats via the intraperitoneally route during four weeks. Results showed that e-liquid with or without nicotine leads to diminished sperm density and viability, such as a decrease in testicular lactate dehydrogenase activity and testosterone level. Furthermore, quantitative real-time polymerase chain reaction (qRT-PCR) analysis identified a reduction in cytochrome P450 side-chain cleavage (P450 scc) and 17 beta-hydroxysteroid dehydrogenase (17βHSD) mRNA level, two key enzymes of steroidogenesis. Following e-liquid exposure, histopathological examination showed alterations in testis tissue marked by germ cells desquamation, disorganization of the tubular contents of testis and cell deposits in seminiferous tubules. Finally, analysis of oxidative stress status pointed an outbreak of antioxidant enzyme activities such as superoxide dismutase, catalase and gluthatione-S-transferase, as well as an important increase in sulfhydril group content. Taken together, these results indicate that e-liquid per se induces toxicity in Wistar rat testis, similar to e-liquid with nicotine, by disrupting oxidative balance and steroidogenesis.

  15. Toxicological and analytical assessment of e-cigarette refill components on airway epithelia.

    Science.gov (United States)

    Singh, Jasjot; Luquet, Emilie; Smith, David P T; Potgieter, Herman J; Ragazzon, Patricia

    2016-12-01

    There are over 2.6 million users of e-cigarettes in the United Kingdom alone as they have been promoted as a safer alternative to traditional cigarettes. The addition of flavours and aromas has also proven to be popular with younger generations. In this review, we survey the range of studies in the short timeframe since e-cigarettes reached the market to draw attention to the health associated risks and benefits of their introduction. We complement this review with a case study reporting on the composition of selected e-cigarette refills with particular emphasis on the toxicological activity of its components on lung cells.

  16. Assessing medication adherence in inflammatory bowel diseases. A comparison between a self-administered scale and a pharmacy refill index.

    Science.gov (United States)

    de Castro, María Luisa; Sanromán, Luciano; Martín, Alicia; Figueira, Montserrat; Martínez, Noemi; Hernández, Vicent; Del Campo, Victor; Pineda, Juan R; Martínez-Cadilla, Jesús; Pereira, Santos; Rodríguez Prada, José Ignacio

    2017-08-01

    Medication non-adherence in inflammatory bowel disease (IBD) has a negative impact on disease outcome. Different tools have been proposed to assess non-adherence. We aimed to compare a self-administered scale and a pharmacy refill index as a reliable measure of medication adherence and to determine what factors are related to adherence. Consecutive non-active IBD outpatients were asked to fill in the self-reported Morisky Medication Adherence Scale (MMAS-8) and the Beliefs about Medication Questionnaire (BMQ). Pharmacy refill data were reviewed from the previous three or six months and the medication possession ratio (MPR) was calculated. Non-adherence was defined as MMAS-8 scores harm of medication were significantly associated with MPR non-adherence (p = 0.01). The accuracy of MMAS-8 to identify medication non-adherence in inactive IBD outpatients in our setting is poor due to a low specificity and a negative predictive value. Psychosocial factors such as beliefs about medication seem to be related to IBD non-adherence.

  17. Fluiddynamic effects in the fuel element top nozzle area during refilling and reflooding

    International Nuclear Information System (INIS)

    Hawighorst, A.; Kroening, H.; Mewes, D.; Spatz, R.; Mayinger, F.

    1985-01-01

    During the refilling and reflooding phase following a hypothetical loss of coolant accident in lightwater cooled nuclear reactors, there will be countercurrent flow between discharging steam and the feed of emergency core cooling water. It was the objective of this research project to contribute to a better physical understanding of the fluiddynamic processes in the area of the fuel element top nozzle and so to improve emergency core cooling calculations. Therefore, experimental and theoretical investigations about the entrainment and countercurrent behaviour of gas/liquid flows have been implemented within this project. Fluiddynamic processes in the fuel element top nozzle area were simulated during the reflooding and refilling phase. Based on special internals as single and multiple-hole orifices, basic phenomena of fluidynamics were studied first with air-water. Subsequently, investigations of the system steam/water were conducted. The reactor geometry was approximated step by step, until a complete reactor fuel assembly top nozzle was constituted. The system pressure was 4.8 bars (abs), in accordance with the conditions in the reactor pressure vessel at the end of the blowdown phase. The water was initially fed in at saturation temperature, then, as a second step, fed in at subcooled condition relative to the steam temperature, in order to be able to study condensation effects as well. First, investigations on gas/liquid countercurrent flows in the fluid system air/water are presented. Then one studies countercurrent flow in the system steam/water, including the investigation of condensation effects. Finally, a detailed description of the research on droplet size determination is given

  18. The Study of the plasmaspheric refilling using the data from the ERG, the VAPs, the ground-based magnetometers and the IPE model

    Science.gov (United States)

    Obana, Y.; Maruyama, N.; Masahito, N.; Matsuoka, A.; Teramoto, M.; Nomura, R.; Fujimoto, A.; Tanaka, Y.; Shinohara, M.; Kasahara, Y.; Matsuda, S.; Kumamoto, A.; Tsuchiya, F.; Yoshizumi, M.; Shinohara, I.

    2017-12-01

    Earth's inner magnetosphere is a complex dynamical region of geo space comprising plasma populations with wide energy ranges, the plasmasphere, ring current, and radiation belts. They form a closely coupled system, thus, the plasmasphere is the lowest energy population in the inner magnetosphere, but the accurate prediction of the evolution of the plasmasphere is critical in understanding the dynamics of the inner magnetosphere, which include even the highest energy population, the radiation belts. In this study, we study plasmaspheric refilling following geomagnetic storms using data from ERG-MGF, ERG-PWE, RBSP-EMFISIS and Ground-based magneto­meters. DC magnetic field data measured by ERG-MGF, RBSP-EMFISIS and ground-based magnetometers provides the frequency of the toroidal mode field line resonances. From this information, the equatorial plasma mass density is estimated by solving the MHD wave equation for suitable models of the magnetic field and the field line density distribution. ERG-PWE and RBSP-EMFISIS provide measurements of wave electric and magnetic field, thus we can estimate the local electron density from the plasma wave spectrograms by identifying narrow-band emission at the upper-hybrid resonance frequency. Furthermore, using Ionosphere Plasmasphere Electrodynamics Model (IPE), we calculate the plasmaspheric refilling rates and evaluate the relative contribution of various mechanisms (heating, neutral particle density, composition and wings, etc.) to the refilling rate.

  19. Refill adherence and persistence to lipid‐lowering medicines in patients with type 2 diabetes: A nation‐wide register‐based study

    Science.gov (United States)

    Hero, Christel; Eliasson, Björn; Franzén, Stefan; Svensson, Ann‐Marie; Miftaraj, Mervete; Gudbjörnsdottir, Soffia; Eeg‐Olofsson, Katarina; Andersson Sundell, Karolina

    2017-01-01

    Abstract Purpose This study aimed to describe and compare refill adherence and persistence to lipid‐lowering medicines in patients with type 2 diabetes by previous cardiovascular disease (CVD). Methods We followed 97 595 patients (58% men; 23% with previous CVD) who were 18 years of age or older when initiating lipid‐lowering medicines in 2007–2010 until first fill of multi‐dose dispensed medicines, death, or 3 years. Using personal identity numbers, we linked individuals' data from the Swedish Prescribed Drug Register, the Swedish National Diabetes Register, the National Patient Register, the Cause of Death Register, and the Longitudinal Integration Database for Health Insurance and Labour Market Studies. We assessed refill adherence using the medication possession ratio (MPR) and the maximum gap method, and measured persistence from initiation to discontinuation of treatment or until 3 years after initiation. We analyzed differences in refill adherence and persistence by previous CVD in multiple regression models, adjusted for socioeconomic status, concurrent medicines, and clinical characteristics. Results The mean age of the study population was 64 years, 80% were born in Sweden, and 56% filled prescriptions for diabetes medicines. Mean MPR was 71%, 39% were adherent according to the maximum gap method, and mean persistence was 758 days. Patients with previous CVD showed higher MPR (3%) and lower risk for discontinuing treatment (12%) compared with patients without previous CVD (P < 0.0001). Conclusions Patients with previous CVD were more likely to be adherent to treatment and had lower risk for discontinuation compared with patients without previous CVD. PMID:28799214

  20. Evidence of refilled chamber gas pressure enhancing cooling rate during melt spinning of a Zr50Cu40Al10 alloy

    Directory of Open Access Journals (Sweden)

    Hong-wang Yang

    2015-07-01

    Full Text Available The influence of the refilled gas pressure on the glass forming behaviour of one of the best ternary glass forming alloys Zr50Cu40Al10 was studied for the melt spinning process. The amorphicity of as-quenched ribbons was characterized by X-ray diffraction (XRD and differential scanning calorimetry (DSC. The refilled chamber atmospheric pressure is crucial to the cooling rate of melt spinning. At high vacuum, at pressure less than 0.0001 atm, fully crystalline fragments are obtained. Monolithic amorphous ribbons were only obtained at a gas pressure of 0.1 atm or higher. The extended contact length between thecribbons and the copper wheel contributes to the high cooling rate of melt spinning. Higher chamber gas pressure leads to more turbulence of liquid metal beneath the nozzle; therefore, lower pressure is preferable at practical melt spinning processes once glass forming conditions are fulfilled.

  1. Refilling process in the plasmasphere: a 3-D statistical characterization based on Cluster density observations

    Directory of Open Access Journals (Sweden)

    G. Lointier

    2013-02-01

    Full Text Available The Cluster mission offers an excellent opportunity to investigate the evolution of the plasma population in a large part of the inner magnetosphere, explored near its orbit's perigee, over a complete solar cycle. The WHISPER sounder, on board each satellite of the mission, is particularly suitable to study the electron density in this region, between 0.2 and 80 cm−3. Compiling WHISPER observations during 1339 perigee passes distributed over more than three years of the Cluster mission, we present first results of a statistical analysis dedicated to the study of the electron density morphology and dynamics along and across magnetic field lines between L = 2 and L = 10. In this study, we examine a specific topic: the refilling of the plasmasphere and trough regions during extended periods of quiet magnetic conditions. To do so, we survey the evolution of the ap index during the days preceding each perigee crossing and sort out electron density profiles along the orbit according to three classes, namely after respectively less than 2 days, between 2 and 4 days, and more than 4 days of quiet magnetic conditions (ap ≤ 15 nT following an active episode (ap > 15 nT. This leads to three independent data subsets. Comparisons between density distributions in the 3-D plasmasphere and trough regions at the three stages of quiet magnetosphere provide novel views about the distribution of matter inside the inner magnetosphere during several days of low activity. Clear signatures of a refilling process inside an expended plasmasphere in formation are noted. A plasmapause-like boundary, at L ~ 6 for all MLT sectors, is formed after 3 to 4 days and expends somewhat further after that. In the outer part of the plasmasphere (L ~ 8, latitudinal profiles of median density values vary essentially according to the MLT sector considered rather than according to the refilling duration. The shape of these density profiles indicates that magnetic flux tubes are not

  2. Forensic medical evaluation of deaths resulting from inhalation of cigarette lighter refill fuel in Turkey.

    Science.gov (United States)

    Özdemir, Erdinç; Eş, Hüseyin; Demir, Muhammet; Üzün, İbrahim

    2017-01-01

    Voluntary inhalation/abuse of volatile substances is an important public health problem which especially affects adolescent and young populations worldwide and may be encountered in all socioeconomic and cultural levels. Lighter gas abuse-related death is still an important health problem in Turkey. In this study, 25,265 case files and final reports submitted to the Institute of Forensic Medicine of the First Specialization Board between January 2011 and December 2015 were evaluated retrospectively. In 56 of these cases, lighter gas inhalation (n-butane, propane, isobutane) was recorded as the cause of death. All subjects were male with a mean age of 16.8years. According to eyewitness and crime scene investigation reports, in 48 (85.7%) of the cases, a lighter refill container was found at the scene. It was determined that 21.4% of the cases used a plastic bag to increase the effects of lighter gas and 76.8% inhaled the lighter gas via their mouth and nose. The toxicological analysis of the samples taken while hospitalized showed no lighter refill components (n-butane, propane, isobutane) in 66% of the cases, n-butane in 32.1% of the cases, and n-butane+propane+isobutane in 1.9% of the cases. The importance of lighter gas inhalation-related deaths in Turkey has been increasing. Strict measures against the abuse of these very dangerous substances should be undertaken by the mutual efforts of medical specialists and legislators. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Effect of Sleeve Plunge Depth on Microstructure and Mechanical Properties of Refill Friction Stir Spot Welding of 2198 Aluminum Alloy

    Science.gov (United States)

    Yue, Yumei; Shi, Yao; Ji, Shude; Wang, Yue; Li, Zhengwei

    2017-10-01

    Refill friction stir spot welding (RFSSW) is a new spot welding technology, by which spot joint without keyhole can be obtained. In this work, RFSSW was used to join 2-mm-thick 2198-T8 aluminum alloy sheets and effects of the sleeve plunge depth on microstructure and lap shear properties of the joints were mainly discussed. Results showed that when using small plunge depths of 2.4 and 2.6 mm, joints showed good formation and no defects were observed. Incomplete refilling defect was observed with increasing plunge depth due to material loss during welding. Size of the grains at sleeve-affected zone (SAZ) is smaller than that at the pin-affected zone, and the size becomes bigger with increasing the plunge depth. More secondary phase particles can be observed at SAZ with increasing the sleeve plunge depth. The lap shear failure load firstly increased and then decreased with increasing the sleeve plunge depth. The maximum failure load of 9819 N was attained with plug fracture mode when using 2.6 mm. Fracture morphologies show ductile fracture mode.

  4. Occurrence of heterotrophic and coliform bacteria in liquid hand soaps from bulk refillable dispensers in public facilities.

    Science.gov (United States)

    Chattman, Marisa; Gerba, Sheri L; Maxwell, Charles P

    2011-03-01

    The goal of the study discussed in this article was to determine the occurrence of heterotrophic and coliform bacteria in liquid soap from bulk refillable dispensers, obtained from restrooms in a variety of public facilities. A total of 541 samples was collected from five U.S. cities. Liquid soap from dispensers in public areas was found to contain heterotrophic and coliform bacterial numbers averaging more than 106 CFU/mL in 24.8% of the dispensers.

  5. Implementation of Geographical Information System for Bacteriological Contamination Analysis on Refill Drinking Water Depot (Study in Tembalang District)

    Science.gov (United States)

    Rahmitha, Amelia; Utami, Endang Sri; Sitohang, Marya Yenita

    2018-02-01

    People used refilled-drinking-water for household and food stall because its efficient and low cost. Based on Indonesian Health Ministry regulation, it should not have any coliform bacteria. This study aimed to describe the bacteriological contamination of refilled drinking water using geographical information system (GIS). In this research, it was used an analytic observational method. The samples were from all available (37) depots in Tembalang district, one form each depot took used a sterile bottle. Contamination of bacteria was identified by Most Probable Number (MPN) method lactose broth media, Mac Conkey media, and IMVIC media. The depot samples were then plotted on (GIS). This study showed 95% samples were not feasible to consume since they contamined coliform. All sub-district had one that contaminated by coliform, 75% sub-districts had depots that contaminated Escherichia coli, while 55% sub-districts had depots that contaminated with other bacteria. The internal risk factors of the contamination were the absence of hygiene-sanitation worthy certificate (95%), depots location near to pollution sources (5%), and the misused of UV light. The external risk factor was lack of quality control that was not as the sterilization from office health Semarang city. Policy reinforcement should be done to all of the depots.

  6. Bad news about an old poison. A case of nicotine poisoning due to both ingestion and injection of the content of an electronic cigarette refill

    Directory of Open Access Journals (Sweden)

    Gianfranco Cervellin

    2013-10-01

    Full Text Available There are increasing concerns about the escalating use of electronic cigarettes (e-cigarettes. In particular, smokers have been advised by important agencies such as the US Food and Drug Administration about the potential harm to the health of these products, being now considered as drug delivery devices. The leading issues supporting this statement include the repeated inhalation of propylene glycol that is used as a diluent in refills, accidental poisoning, as well as evidence that ecigarettes may promote continued smoking since their use may compromise quitting motivations. Some authors have minimized these risks, considering the potential advantages of these devices for public health. Here we describe the first case of nicotine poisoning due to both ingestion and intravenous injection of the content of an e-cigarette refill, incorrectly mixed with methadone, bottled in a generic vial.

  7. A remotely operated drug delivery system with an electrolytic pump and a thermo-responsive valve

    KAUST Repository

    Yi, Ying

    2015-07-22

    Implantable drug delivery devices are becoming attractive due to their abilities of targeted and controlled dose release. Currently, two important issues are functional lifetime and non-controlled drug diffusion. In this work, we present a drug delivery device combining an electrolytic pump and a thermo-responsive valve, which are both remotely controlled by an electromagnetic field (40.5 mT and 450 kHz). Our proposed device exhibits a novel operation mechanism for long-term therapeutic treatments using a solid drug in reservoir approach. Our device also prevents undesired drug liquid diffusions. When the electromagnetic field is on, the electrolysis-induced bubble drives the drug liquid towards the Poly (N-Isopropylacrylamide) (PNIPAM) valve that consists of PNIPAM and iron micro-particles. The heat generated by the iron micro-particles causes the PNIPAM to shrink, resulting in an open valve. When the electromagnetic field is turned off, the PNIPAM starts to swell. In the meantime, the bubbles are catalytically recombined into water, reducing the pressure inside the pumping chamber, which leads to the refilling of the fresh liquid from outside the device. A catalytic reformer is included, allowing more liquid refilling during the limited valve\\'s closing time. The amount of body liquid that refills the drug reservoir can further dissolve the solid drug, forming a reproducible drug solution for the next dose. By repeatedly turning on and off the electromagnetic field, the drug dose can be cyclically released, and the exit port of the device is effectively controlled.

  8. A remotely operated drug delivery system with an electrolytic pump and a thermo-responsive valve

    KAUST Repository

    Yi, Ying; Zaher, Amir; Yassine, Omar; Kosel, Jü rgen; Foulds, Ian G.

    2015-01-01

    Implantable drug delivery devices are becoming attractive due to their abilities of targeted and controlled dose release. Currently, two important issues are functional lifetime and non-controlled drug diffusion. In this work, we present a drug delivery device combining an electrolytic pump and a thermo-responsive valve, which are both remotely controlled by an electromagnetic field (40.5 mT and 450 kHz). Our proposed device exhibits a novel operation mechanism for long-term therapeutic treatments using a solid drug in reservoir approach. Our device also prevents undesired drug liquid diffusions. When the electromagnetic field is on, the electrolysis-induced bubble drives the drug liquid towards the Poly (N-Isopropylacrylamide) (PNIPAM) valve that consists of PNIPAM and iron micro-particles. The heat generated by the iron micro-particles causes the PNIPAM to shrink, resulting in an open valve. When the electromagnetic field is turned off, the PNIPAM starts to swell. In the meantime, the bubbles are catalytically recombined into water, reducing the pressure inside the pumping chamber, which leads to the refilling of the fresh liquid from outside the device. A catalytic reformer is included, allowing more liquid refilling during the limited valve's closing time. The amount of body liquid that refills the drug reservoir can further dissolve the solid drug, forming a reproducible drug solution for the next dose. By repeatedly turning on and off the electromagnetic field, the drug dose can be cyclically released, and the exit port of the device is effectively controlled.

  9. Relationship between medication beliefs, self-reported and refill adherence, and symptoms in patients with asthma using inhaled corticosteroids

    Directory of Open Access Journals (Sweden)

    Van Steenis MNA

    2014-01-01

    Full Text Available MNA Van Steenis,1 JA Driesenaar,2 JM Bensing,2,3 R Van Hulten,4 PC Souverein,4 L Van Dijk,2,4 PAGM De Smet,5 AM Van Dulmen2,6,71Department of Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands; 2NIVEL (Netherlands institute for health services research, Utrecht, The Netherlands; 3Department of Psychology, Faculty of Social and Behavioural Sciences, Utrecht University, Utrecht, The Netherlands; 4Division of Pharmacoepidemiology and Clinical Pharmacology, Utrecht University, Utrecht, The Netherlands; 5IQ Healthcare, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands; 6Department of Primary and Community Care, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands; 7Department of Health Sciences, Buskerud University College, Drammen, NorwayBackground: Beliefs play a crucial role in medication adherence. Interestingly, the relationship between beliefs and adherence varies when different adherence measures are used. How adherence, in turn, is related to asthma symptoms is still unclear. Our aim was to investigate the relationship between beliefs (ie, necessities and concerns about inhaled corticosteroids (ICS and subjectively as well as objectively measure adherence and the agreement between these measures. Further, the relationship between adherence and asthma symptoms was examined.Methods: A total of 280 patients aged 18–80 years who filled at least two ICS prescriptions in the preceding year were recruited to complete a questionnaire. The questionnaire included the Beliefs about Medicines Questionnaire to assess necessity beliefs and concerns about ICS, four questions about ICS use to measure self-reported adherence, and the Asthma Control Questionnaire to assess asthma symptoms. Proportion of days covered was used to determine pharmacy refill adherence.Results: Data from 93 patients with asthma were analyzed. Necessities were positively related to self-reported adherence (P = 0.01. No other

  10. Optimization of a Differential Ion Mobility Spectrometry-Tandem Mass Spectrometry Method for High-Throughput Analysis of Nicotine and Related Compounds: Application to Electronic Cigarette Refill Liquids.

    Science.gov (United States)

    Regueiro, Jorge; Giri, Anupam; Wenzl, Thomas

    2016-06-21

    Fast market penetration of electronic cigarettes is leading to an exponentially growing number of electronic refill liquids with different nicotine contents and an endless list of flavors. Therefore, rapid and simple methods allowing a fast screening of these products are necessary to detect harmful substances which can negatively impact the health of consumers. In this regard, the present work explores the capabilities of differential ion mobility spectrometry coupled to tandem mass spectrometry for high-throughput analysis of nicotine and 11 related compounds in commercial refill liquids for electronic cigarettes. The influence of main factors affecting the ion mobility separation, such as modifier types and concentration, separation voltage, and temperature, was systematically investigated. Despite small molecular weight differences among the studied compounds, a good separation was achieved in the ion mobility cell under the optimized conditions, which involved the use of ethanol as a polar gas-phase chemical modifier. Indeed, differential ion mobility was able to resolve (resolution >4) nicotine from its structural isomer anabasine without the use of any chromatographic separation. The quantitative performance of the proposed method was then evaluated, showing satisfactory precision (RSD ≤ 16%) and recoveries ranging from 85 to 100% for nicotine, and from 84 to 126% for the rest of the target analytes. Several commercial electronic cigarette refill liquids were analyzed to demonstrate the applicability of the method. In some cases, significant differences were found between labeled and measured levels of nicotine. Anatabine, cotinine, myosmine, and nornicotine were also found in some of the analyzed samples.

  11. Microstructure and failure mechanisms of refill friction stir spot welded 7075-T6 aluminum alloy joints

    International Nuclear Information System (INIS)

    Shen, Zhikang; Yang, Xinqi; Zhang, Zhaohua; Cui, Lei; Li, Tielong

    2013-01-01

    Highlights: ► There is a correlation between the void in the weld and the joint strength. ► The preferable mechanical properties can be obtained by lowering rotational speed. ► The alclad has an adverse effect on the mechanical properties. -- Abstract: In this paper, the microstructure and mechanical properties of 7075-T6 aluminum alloy joints joined by refill friction stir spot welding (RFSSW) were investigated. The keyhole was refilled successfully, and the microstructure of the weld exhibited variations in the grain sizes in the width and the thickness directions. There existed defects (hook, voids, bonding ligament, etc.) associated to the material flow in the weld. Mechanical properties of the joint have been investigated in terms of hardness and tensile/shear and cross-tension test, and the fracture mechanisms were observed by SEM (scanning electron microscope). The hardness profile of the weld exhibited a W-shaped appearance in the macroscopic level, which reached the minimum at the boundary of the sleeve and the clamping ring. The variation laws between tensile/shear and cross-tension strength and processing parameters were rather complicated. The void in the weld played an important role in determining the strength of the joint. On the whole, the preferable strength can be obtained at lower rotational speed. Shear fracture mode was observed under tensile–shear loadings, and nugget debonding, plug type fracture (on the upper sheet) and plug type fracture (on the lower sheet) modes were observed under cross-tension loadings. It was also observed that the main feature affecting the mechanical properties of the joint is the alclad between the upper and lower sheets and the connecting qualities between the stir zone and thermo-mechanically affected zone.

  12. Hidden Markov Item Response Theory Models for Responses and Response Times.

    Science.gov (United States)

    Molenaar, Dylan; Oberski, Daniel; Vermunt, Jeroen; De Boeck, Paul

    2016-01-01

    Current approaches to model responses and response times to psychometric tests solely focus on between-subject differences in speed and ability. Within subjects, speed and ability are assumed to be constants. Violations of this assumption are generally absorbed in the residual of the model. As a result, within-subject departures from the between-subject speed and ability level remain undetected. These departures may be of interest to the researcher as they reflect differences in the response processes adopted on the items of a test. In this article, we propose a dynamic approach for responses and response times based on hidden Markov modeling to account for within-subject differences in responses and response times. A simulation study is conducted to demonstrate acceptable parameter recovery and acceptable performance of various fit indices in distinguishing between different models. In addition, both a confirmatory and an exploratory application are presented to demonstrate the practical value of the modeling approach.

  13. Anti-osteoporotic therapy in Denmark-predictors and demographics of poor refill compliance and poor persistence

    DEFF Research Database (Denmark)

    Hansen, C; Pedersen, Birthe D.; Konradsen, H

    2013-01-01

    In this study of 100,949 new users of oral bisphosphonates age ≥35 years, "early quitters" were found to differ from others with poor refill compliance in terms of socioeconomic, demographic, and treatment-related characteristics. New risk factors for poor compliance and persistence were identified...... quitters" were associated with high household income, subjects' age 71.9-79 years, living in the countryside or village, prior treatment with analgesics and anti-parkinson drugs, and dementia. Differences concerning decreased risk of "early quitters" were associated with male, living in an apartment......, children living at home, living close to a university hospital, anti-osteoporotic therapy other than alendronate, number of drugs especially above three, pulmonary disease, collagen disease. CONCLUSION: The results suggest a need for improved support for patients to facilitate the interpretation...

  14. Response moderation models for conditional dependence between response time and response accuracy.

    Science.gov (United States)

    Bolsinova, Maria; Tijmstra, Jesper; Molenaar, Dylan

    2017-05-01

    It is becoming more feasible and common to register response times in the application of psychometric tests. Researchers thus have the opportunity to jointly model response accuracy and response time, which provides users with more relevant information. The most common choice is to use the hierarchical model (van der Linden, 2007, Psychometrika, 72, 287), which assumes conditional independence between response time and accuracy, given a person's speed and ability. However, this assumption may be violated in practice if, for example, persons vary their speed or differ in their response strategies, leading to conditional dependence between response time and accuracy and confounding measurement. We propose six nested hierarchical models for response time and accuracy that allow for conditional dependence, and discuss their relationship to existing models. Unlike existing approaches, the proposed hierarchical models allow for various forms of conditional dependence in the model and allow the effect of continuous residual response time on response accuracy to be item-specific, person-specific, or both. Estimation procedures for the models are proposed, as well as two information criteria that can be used for model selection. Parameter recovery and usefulness of the information criteria are investigated using simulation, indicating that the procedure works well and is likely to select the appropriate model. Two empirical applications are discussed to illustrate the different types of conditional dependence that may occur in practice and how these can be captured using the proposed hierarchical models. © 2016 The British Psychological Society.

  15. A new refillable Cobalt-57 flood phantom to measure camera uniformity

    International Nuclear Information System (INIS)

    Dias-Neto, A.; Silva, C.P.G. da; Osso, J.

    1997-01-01

    Full text: The system uniformity of a scintillation camera is assessed using an extended Tc-99m source: a well constructed flood phantom, filled with a solution of Tc-99m pertechnetate, that does not bulge and is well mixed. A convenient substitute is a commercial solid Co-57 sheet source, which is expensive (5k-10k USS), has a relative short life-span (1,5 - 2 years), and, may not be quite uniform. As an alternative, an inexpensive fillable Co-57 flood source is presented. For pilot testing, a plastic flood phantom was filled with a solution of Co-57 chloride produced by IPEN's cyclotron. Special filling plugs with O-rings were used to avoid any leakage. High count uniformity images, using a low-energy high-resolution collimator and 15% energy windows, were obtained with the fillable Co-57 source, a commercial Co-57 sheet source, and a Tc-99 source. The data were compared visually and quantified with the NEMA uniformity parameters. The fillable Co-57 source compared favourably with the other sources. A shock-proof flood phantom is at present under development. This phantom is intended to be refilled annually with Co-57, at a fraction of the cost of a commercial sheet source. (authors)

  16. Response Mixture Modeling: Accounting for Heterogeneity in Item Characteristics across Response Times.

    Science.gov (United States)

    Molenaar, Dylan; de Boeck, Paul

    2018-06-01

    In item response theory modeling of responses and response times, it is commonly assumed that the item responses have the same characteristics across the response times. However, heterogeneity might arise in the data if subjects resort to different response processes when solving the test items. These differences may be within-subject effects, that is, a subject might use a certain process on some of the items and a different process with different item characteristics on the other items. If the probability of using one process over the other process depends on the subject's response time, within-subject heterogeneity of the item characteristics across the response times arises. In this paper, the method of response mixture modeling is presented to account for such heterogeneity. Contrary to traditional mixture modeling where the full response vectors are classified, response mixture modeling involves classification of the individual elements in the response vector. In a simulation study, the response mixture model is shown to be viable in terms of parameter recovery. In addition, the response mixture model is applied to a real dataset to illustrate its use in investigating within-subject heterogeneity in the item characteristics across response times.

  17. Assessing medication adherence in inflammatory bowel diseases: a comparison between a self-administered scale and a pharmacy refill index

    Directory of Open Access Journals (Sweden)

    María-Luisa de-Castro

    Full Text Available Background: Medication non-adherence in inflammatory bowel disease (IBD has a negative impact on disease outcome. Different tools have been proposed to assess non-adherence. We aimed to compare a self-administered scale and a pharmacy refill index as a reliable measure of medication adherence and to determine what factors are related to adherence. Methods: Consecutive non-active IBD outpatients were asked to fill in the self-reported Morisky Medication Adherence Scale (MMAS-8 and the Beliefs about Medication Questionnaire (BMQ. Pharmacy refill data were reviewed from the previous three or six months and the medication possession ratio (MPR was calculated. Non-adherence was defined as MMAS-8 scores < 6 or MPR < 0.8. Results: Two-hundred and three patients were enrolled (60% ulcerative colitis, 40% Crohn's disease; 51% were men, and the mean age was 46.3 (14 years. Seventy-four per cent of patients were on monotherapy and 26% on combination therapy; altogether, 65% received mesalazine, 46% thiopurines and 16% anti-tumor necrosis factor alfa. Non-adherence rate assessed by MPR was 37% and 22.4% by MMAS-8. Receiver operator curve analysis using a MMAS-8 cut-off of six gave an area under the curve of 0.6 (95% CI 0.5-0.7, p = 0.001. This score had an 85% sensitivity and 34% specificity to predict medication non-adherence, with negative and positive predictive values of 57% and 70% respectively. High scores in the BMQ potential for harm of medication were significantly associated with MPR non-adherence (p = 0.01. Conclusion: The accuracy of MMAS-8 to identify medication non-adherence in inactive IBD outpatients in our setting is poor due to a low specificity and a negative predictive value. Psychosocial factors such as beliefs about medication seem to be related to IBD non-adherence.

  18. Texture Development and Material Flow Behavior During Refill Friction Stir Spot Welding of AlMgSc

    Science.gov (United States)

    Shen, Junjun; Lage, Sara B. M.; Suhuddin, Uceu F. H.; Bolfarini, Claudemiro; dos Santos, Jorge F.

    2018-01-01

    The microstructural evolution during refill friction stir spot welding of an AlMgSc alloy was studied. The primary texture that developed in all regions, with the exception of the weld center, was determined to be 〈110〉 fibers and interpreted as a simple shear texture with the 〈110〉 direction aligned with the shear direction. The material flow is mainly driven by two components: the simple shear acting on the horizontal plane causing an inward-directed spiral flow and the extrusion acting on the vertical plane causing an upward-directed or downward-directed flow. Under such a complex material flow, the weld center, which is subjected to minimal local strain, is the least recrystallized. In addition to the geometric effects of strain and grain subdivision, thermally activated high-angle grain boundary migration, particularly continuous dynamic recrystallization, drives the formation of refined grains in the stirred zone.

  19. In vitro human epidermal permeation of nicotine from electronic cigarette refill liquids and implications for dermal exposure assessment.

    Science.gov (United States)

    Frasch, H Frederick; Barbero, Ana M

    2017-11-01

    Nicotine plus flavorings in a propylene glycol (PG) vehicle are the components of electronic cigarette liquids (e-liquids), which are vaporized and inhaled by the user. Dermal exposure to nicotine and e-liquids may occur among workers in mixing and filling of e-cigarettes in the manufacturing process. Inadvertent skin contact among consumers is also a concern. In vitro nicotine permeation studies using heat-separated human epidermis were performed with surrogate and two commercial e-liquids, neat and aqueous nicotine donor formulations. Steady-state fluxes (J ss ), and lag times (t lag ) were measured for each formulation. In addition, transient (4 h) exposure and finite dose (1-10 μl/cm 2 ) experiments were undertaken using one commercial e-liquid. Average J ss (μg/cm 2 /h) from formulations were: nicotine in PG (24 mg/ml): 3.97; commercial e-liquid containing menthol (25 mg/ml nicotine): 10.2; commercial e-liquid containing limonene (25 mg/ml nicotine): 23.7; neat nicotine: 175. E-liquid lag times ranged from 5 to 10 h. Absorbed fraction of nicotine from finite doses was ≈0.3 at 48 h. The data were applied to transient exposure and finite dose dermal exposure assessment models and to a simple pharmacokinetic model. Three illustrative exposure scenarios demonstrate use of the data to predict systemic uptake and plasma concentrations from dermal exposure. The data demonstrate the potential for significant nicotine absorption through skin contact with e-cigarette refill solutions and the neat nicotine used to mix them.

  20. Bad news about an old poison. A case of nicotine poisoning due to both ingestion and injection of the content of an electronic cigarette refill

    OpenAIRE

    Gianfranco Cervellin; Michele Luci; Carlotta Bellini; Giuseppe Lippi

    2013-01-01

    There are increasing concerns about the escalating use of electronic cigarettes (e-cigarettes). In particular, smokers have been advised by important agencies such as the US Food and Drug Administration about the potential harm to the health of these products, being now considered as drug delivery devices. The leading issues supporting this statement include the repeated inhalation of propylene glycol that is used as a diluent in refills, accidental poisoning, as well as evidence that ecigare...

  1. Influence of Soap Characteristics and Food Service Facility Type on the Degree of Bacterial Contamination of Open, Refillable Bulk Soaps.

    Science.gov (United States)

    Schaffner, Donald W; Jensen, Dane; Gerba, Charles P; Shumaker, David; Arbogast, James W

    2018-02-01

    Concern has been raised regarding the public health risks from refillable bulk-soap dispensers because they provide an environment for potentially pathogenic bacteria to grow. This study surveyed the microbial quality of open refillable bulk soap in four different food establishment types in three states. Two hundred ninety-six samples of bulk soap were collected from food service establishments in Arizona, New Jersey, and Ohio. Samples were tested for total heterotrophic viable bacteria, Pseudomonas, coliforms and Escherichia coli, and Salmonella. Bacteria were screened for antibiotic resistance. The pH, solids content, and water activity of all soap samples were measured. Samples were assayed for the presence of the common antibacterial agents triclosan and parachlorometaxylenol. More than 85% of the soap samples tested contained no detectable microorganisms, but when a sample contained any detectable microorganisms, it was most likely contaminated at a very high level (∼7 log CFU/mL). Microorganisms detected in contaminated soap included Klebsiella oxytoca, Serratia liquefaciens, Shigella sonnei, Enterobacter gergoviae, Serratia odorifera, and Enterobacter cloacae. Twenty-three samples contained antibiotic-resistant organisms, some of which were resistant to two or more antibiotics. Every sample containing less than 4% solids had some detectable level of bacteria, whereas no samples with greater than 14% solids had detectable bacteria. This finding suggests the use of dilution and/or low-cost formulations as a cause of bacterial growth. There was a statistically significant difference ( P = 0.0035) between the fraction of bacteria-positive samples with no detected antimicrobial agent (17%) and those containing an antimicrobial agent (7%). Fast food operations and grocery stores were more likely to have detectable bacteria in bulk-soap samples compared with convenience stores ( P food service establishments.

  2. Response time patterns in a stated choice experiment

    DEFF Research Database (Denmark)

    Börjesson, Maria; Fosgerau, Mogens

    2015-01-01

    This paper studies how response times vary between unlabelled binary choice occasions in a stated choice (SC) experiment, with alternatives differing with respect to in-vehicle travel time and travel cost. The pattern of response times is interpreted as an indicator of the cognitive processes...... employed by the respondents when making their choices. We find clear signs of reference-dependence in response times in the form of a strong gain–loss asymmetry. Moreover, different patterns of response times for travel time and travel cost indicate that these attributes are processed in different ways...

  3. Transient response of a liquid injector to a steep-fronted transverse pressure wave

    Science.gov (United States)

    Lim, D.; Heister, S.; Stechmann, D.; Kan, B.

    2017-12-01

    Motivated by the dynamic injection environment posed by unsteady pressure gain combustion processes, an experimental apparatus was developed to visualize the dynamic response of a transparent liquid injector subjected to a single steep-fronted transverse pressure wave. Experiments were conducted at atmospheric pressure with a variety of acrylic injector passage designs using water as the working fluid. High-speed visual observations were made of the injector exit near field, and the extent of backflow and the time to refill the orifice passage were characterized over a range of injection pressures. A companion transient one-dimensional model was developed for interpretation of the results and to elucidate the trends with regard to the strength of the transverse pressure wave. Results from the model were compared with the experimental observations.

  4. Effects of ion temperature anisotropy on the interhemispheric plasma transport during plasmaspheric refilling

    International Nuclear Information System (INIS)

    Singh, N.; Torr, D.G.

    1990-01-01

    Effects of temperature anisotropies on the early stage refilling of the outer plasmasphere are studied by solving an appropriate set of hydrodynamic equations. The anisotropies result from the supersonic outflows from the conjugate ionospheres and from the perpendicular ion heating in the equatorial region. The equatorial ion heating affected by wave-particle interaction is included phenomenologically. Even for the equatorial heating associated with moderate wave levels, the mirror force on the flows severely limits the interhemispheric plasma exchange. The temporal evolution of the flow developing in an empty flux tube is characterized by: (1) supersonic plasma outflows from the conjugate ionospheres, (2) reflections of the flows by the mirror force as they begin to penetrate into the opposite hemispheres, (3) formation of shocks in the reflection region and (4) propagations of the shocks to the ionospheres of the origins of the flows. In the quasi-steady state when flow completely subsides, the density distribution in the flux tube shows distinctive large-scale features, determined by the balance between electric, pressure and anisotropy forces. The latter force becomes significant in a broad equatorial region where T t >> T p and also at relatively high geomagnetic latitudes where T t p ; T t and T p are the perpendicular and parallel ion temperatures, respectively

  5. Cognitive Reflection, Decision Biases, and Response Times.

    Science.gov (United States)

    Alós-Ferrer, Carlos; Garagnani, Michele; Hügelschäfer, Sabine

    2016-01-01

    We present novel evidence on response times and personality traits in standard questions from the decision-making literature where responses are relatively slow (medians around half a minute or above). To this end, we measured response times in a number of incentivized, framed items (decisions from description) including the Cognitive Reflection Test, two additional questions following the same logic, and a number of classic questions used to study decision biases in probability judgments (base-rate neglect, the conjunction fallacy, and the ratio bias). All questions create a conflict between an intuitive process and more deliberative thinking. For each item, we then created a non-conflict version by either making the intuitive impulse correct (resulting in an alignment question), shutting it down (creating a neutral question), or making it dominant (creating a heuristic question). For CRT questions, the differences in response times are as predicted by dual-process theories, with alignment and heuristic variants leading to faster responses and neutral questions to slower responses than the original, conflict questions. For decision biases (where responses are slower), evidence is mixed. To explore the possible influence of personality factors on both choices and response times, we used standard personality scales including the Rational-Experiential Inventory and the Big Five, and used them as controls in regression analysis.

  6. The Effect of Sports and Physical Activity on Elderly Reaction Time and Response Time

    Directory of Open Access Journals (Sweden)

    Abdolrahman Khezri

    2014-07-01

    Full Text Available Objectives: Physical activities ameliorate elderly motor and cognitive performance. The aim of this research is to study the effect of sport and physical activity on elderly reaction time and response time. Methods & Materials: The research method is causal-comparative and its statistical population consists of 60 active and non-active old males over 60 years residing at Mahabad city. Reaction time was measured by reaction timer apparatus, made in Takei Company (YB1000 model. Response time was measured via Nelson’s Choice- Response Movement Test. At first, reaction time and then response time was measured. For data analysis, descriptive statistic, K-S Test and One Sample T Test were used Results K-S Test show that research data was parametric. According to the results of this research, physical activity affected reaction time and response time. Results: of T test show that reaction time (P=0.000 and response time (P=0.000 of active group was statistically shorter than non- active group. Conclusion: The result of current study demonstrate that sport and physical activity, decrease reaction and response time via psychomotor and physiological positive changes.

  7. A Box-Cox normal model for response times.

    Science.gov (United States)

    Klein Entink, R H; van der Linden, W J; Fox, J-P

    2009-11-01

    The log-transform has been a convenient choice in response time modelling on test items. However, motivated by a dataset of the Medical College Admission Test where the lognormal model violated the normality assumption, the possibilities of the broader class of Box-Cox transformations for response time modelling are investigated. After an introduction and an outline of a broader framework for analysing responses and response times simultaneously, the performance of a Box-Cox normal model for describing response times is investigated using simulation studies and a real data example. A transformation-invariant implementation of the deviance information criterium (DIC) is developed that allows for comparing model fit between models with different transformation parameters. Showing an enhanced description of the shape of the response time distributions, its application in an educational measurement context is discussed at length.

  8. Time response for sensor sensed to actuator response for mobile robotic system

    Science.gov (United States)

    Amir, N. S.; Shafie, A. A.

    2017-11-01

    Time and performance of a mobile robot are very important in completing the tasks given to achieve its ultimate goal. Tasks may need to be done within a time constraint to ensure smooth operation of a mobile robot and can result in better performance. The main purpose of this research was to improve the performance of a mobile robot so that it can complete the tasks given within time constraint. The problem that is needed to be solved is to minimize the time interval between sensor detection and actuator response. The research objective is to analyse the real time operating system performance of sensors and actuators on one microcontroller and on two microcontroller for a mobile robot. The task for a mobile robot for this research is line following with an obstacle avoidance. Three runs will be carried out for the task and the time between the sensors senses to the actuator responses were recorded. Overall, the results show that two microcontroller system have better response time compared to the one microcontroller system. For this research, the average difference of response time is very important to improve the internal performance between the occurrence of a task, sensors detection, decision making and actuator response of a mobile robot. This research helped to develop a mobile robot with a better performance and can complete task within the time constraint.

  9. The Value of Response Times in Item Response Modeling

    Science.gov (United States)

    Molenaar, Dylan

    2015-01-01

    A new and very interesting approach to the analysis of responses and response times is proposed by Goldhammer (this issue). In his approach, differences in the speed-ability compromise within respondents are considered to confound the differences in ability between respondents. These confounding effects of speed on the inferences about ability can…

  10. Sensor response time monitoring using noise analysis

    International Nuclear Information System (INIS)

    Hashemian, H.M.; Thie, J.A.; Upadhyaya, B.R.; Holbert, K.E.

    1988-01-01

    Random noise techniques in nuclear power plants have been developed for system surveillance and for analysis of reactor core dynamics. The noise signals also contain information about sensor dynamics, and this can be extracted using frequency, amplitude and time domain analyses. Even though noise analysis has been used for sensor response time testing in some nuclear power plants, an adequate validation of this method has never been carried out. This paper presents the results of limited work recently performed to examine the validity of the noise analysis for sensor response time testing in nuclear power plants. The conclusion is that noise analysis has the potential for detecting gross changes in sensor response but it cannot be used for reliable measurement of response time until more laboratory and field experience is accumulated. The method is more advantageous for testing pressure sensors than it is for temperature sensors. This is because: 1) for temperature sensors, a method called Loop Current Step Response test is available which is quantitatively more exact than noise analysis, 2) no method currently exists for on-line testing of pressure transmitters other than the Power-Interrupt test which is applicable only to force balance pressure transmitters, and 3) pressure sensor response time is affected by sensing line degradation which is inherently taken into account by testing with noise analysis. (author)

  11. Incorporating Response Times in Item Response Theory Models of Reading Comprehension Fluency

    Science.gov (United States)

    Su, Shiyang

    2017-01-01

    With the online assessment becoming mainstream and the recording of response times becoming straightforward, the importance of response times as a measure of psychological constructs has been recognized and the literature of modeling times has been growing during the last few decades. Previous studies have tried to formulate models and theories to…

  12. The refilling of pores in cement mortars treated by chemicals and desiccation at different temperatures

    Directory of Open Access Journals (Sweden)

    Menéndez Pazos, Ignacio

    1992-09-01

    Full Text Available Bases under the law of solubility product, the pores of the cement mortar are refilled by impregnation with two salts that form another insoluble salt. The number of treatments to be underdone and the drying temperatures more suitable in each case. The calcium salts like impregnants and urea sodium oxalate and sugar like precipitates are employed, obtained in each case the corresponding pores are occupied, which depends generally on the number of treatments and in particular the drier temperature.

    Basados en los principios del producto de solubilidad, se rellenan los poros de las probetas de mortero de cemento por impregnación con dos sales que forman otra insoluble. Se determina el número de tratamientos a realizar y las temperaturas de secado más idóneas en cada caso. Se emplean sales cálcicas como impregnantes, y urea, oxalato sódico y azúcar como precipitantes, obteniéndose en cada caso las correspondientes ocupaciones de poros que dependen, por lo general, del número de tratamientos y, en particular, de la temperatura de secado.

  13. Response times of operators in a control room

    International Nuclear Information System (INIS)

    Platz, O.; Rasmussen, J.; Skanborg, P.Z.

    1982-12-01

    A statistical analysis was made of operator response times recorded in the control room of a research reactor during the years 1972-1974. A homogeneity test revealed that the data consist of a mixture of populations. A small but statistically significant difference is found between day and night response times. Lognormal distributions are found to provide the best fit of the day and the night response times. (author)

  14. A Comparison of Response Rate, Response Time, and Costs of Mail and Electronic Surveys.

    Science.gov (United States)

    Shannon, David M.; Bradshaw, Carol C.

    2002-01-01

    Compared response rates, response time, and costs of mail and electronic surveys using a sample of 377 college faculty members. Mail surveys yielded a higher response rate and a lower rate of undeliverable surveys, but response time was longer and costs were higher than for electronic surveys. (SLD)

  15. A new method to evaluate patient characteristic response to ultrafiltration during hemodialysis.

    Science.gov (United States)

    Casagrande, G; Teatini, U; Romei Longhena, G; Miglietta, F; Fumero, R; Costantino, M L

    2007-05-01

    Several factors are involved in the pathogenesis of dialysis discomfort interfering with optimal fluid removal and reducing the efficacy of the treatment; the most important one is a decrease in blood volume caused by an imbalance between ultrafiltration (UF) and plasmarefilling (PR) rates. This study is aimed at devising a method to tailor the dialysis therapy to each individual patient, by analyzing the relationship between PR and UF during the sessions in stable patients and widening the knowledge of fluid exchanges during the treatment. Thirty stable patients undergoing maintenance hemodialysis were enrolled. Three dialysis sessions were monitored for each patient; systemic pressure, blood composition, blood volume % variation, weight loss and conductivity were recorded repeatedly. A Plasma Refilling Index (PRI), defined and calculated by means of parameters measured throughout the dialysis, was introduced as a novel instrument to study plasma refilling phenomena. Results. The PRI provides understanding of patient response (in terms of plasma refilling) to the set UF. In the monitored sessions, the PRI trend is found to be characteristic of each patient; a PRI course that is at variance with the characteristic trend is a signal of inadequate or unusual dialysis scheduling. Moreover, statistical analysis highlights two different PRI trends during the first hour and during the rest of the treatment, suggesting the presence of different treatment phases. The main advantage of the PRI index is that it is non-invasive peculiar to each patient and easy to compute in a dialysis routine based on online data recorded by the monitor. A deviation from the characteristic trend may be a warning for the clinician. The analysis of the PRI trend also suggests how to modulate UF as a function of interstitial to intravascular fluid removal balance during dialysis.

  16. The Iowa new practice model: Advancing technician roles to increase pharmacists' time to provide patient care services.

    Science.gov (United States)

    Andreski, Michael; Myers, Megan; Gainer, Kate; Pudlo, Anthony

    Determine the effects of an 18-month pilot project using tech-check-tech in 7 community pharmacies on 1) rate of dispensing errors not identified during refill prescription final product verification; 2) pharmacist workday task composition; and 3) amount of patient care services provided and the reimbursement status of those services. Pretest-posttest quasi-experimental study where baseline and study periods were compared. Pharmacists and pharmacy technicians in 7 community pharmacies in Iowa. The outcome measures were 1) percentage of technician verified refill prescriptions where dispensing errors were not identified on final product verification; 2) percentage of time spent by pharmacists in dispensing, management, patient care, practice development, and other activities; 3) the number of pharmacist patient care services provided per pharmacist hours worked; and 4) percentage of time that technician product verification was used. There was no significant difference in overall errors (0.2729% vs. 0.5124%, P = 0.513), patient safety errors (0.0525% vs. 0.0651%, P = 0.837), or administrative errors (0.2204% vs. 0.4784%, P = 0.411). Pharmacist's time in dispensing significantly decreased (67.3% vs. 49.06%, P = 0.005), and time in direct patient care (19.96% vs. 34.72%, P = 0.003), increased significantly. Time in other activities did not significantly change. Reimbursable services per pharmacist hour (0.11 vs. 0.30, P = 0.129), did not significantly change. Non-reimbursable services increased significantly (2.77 vs. 4.80, P = 0.042). Total services significantly increased (2.88 vs. 5.16, P = 0.044). Pharmacy technician product verification of refill prescriptions preserved dispensing safety while significantly increasing the time spent in delivery of pharmacist provided patient care services. The total number of pharmacist services provided per hour also increased significantly, driven primarily by a significant increase in the number of non

  17. A semi-parametric within-subject mixture approach to the analyses of responses and response times.

    Science.gov (United States)

    Molenaar, Dylan; Bolsinova, Maria; Vermunt, Jeroen K

    2018-05-01

    In item response theory, modelling the item response times in addition to the item responses may improve the detection of possible between- and within-subject differences in the process that resulted in the responses. For instance, if respondents rely on rapid guessing on some items but not on all, the joint distribution of the responses and response times will be a multivariate within-subject mixture distribution. Suitable parametric methods to detect these within-subject differences have been proposed. In these approaches, a distribution needs to be assumed for the within-class response times. In this paper, it is demonstrated that these parametric within-subject approaches may produce false positives and biased parameter estimates if the assumption concerning the response time distribution is violated. A semi-parametric approach is proposed which resorts to categorized response times. This approach is shown to hardly produce false positives and parameter bias. In addition, the semi-parametric approach results in approximately the same power as the parametric approach. © 2017 The British Psychological Society.

  18. The Importance of Responsibility in Times of Crisis

    Directory of Open Access Journals (Sweden)

    Jacob Dahl Rendtorff

    2014-06-01

    Full Text Available In this paper I would like to show the importance of the concept of responsibility as the foundation of ethics in times of crisis in particular in the fields of politics and economics in the modern civilisation marked by globalization and technological progres. I consider the concept of responsibility as the key notion in order to understand the ethical duty in a modern technological civilisation. We can indeed observe a moralization of the concept of responsibility going beyond a strict legal definition in terms of imputability. The paper begins by discussing the humanistic foundations of such a concept of responsibility. It treats the historical origins of responsibility and it relates this concept to the concept of accountability. On the basis of this historical determination of the concept I would like to present the definition of the concept of responsibility as fundamental ethical principle that has increasing importance as the foundation of the principles of governance in modern welfare states. In this context the paper discusses the extension of the concept of responsibility towards institutional or corporate responsibility where responsibility does not only concerns the responsibility of individuals but also deals with the responsibility of institutional collectivities. In this way the paper is based on the following structure : 1 The ethical foundation of the concept of responsibility 2 Responsibility in technological civilisation 3 Political responsibility for good governance in the welfare state 4 Social responsibility of business corporations in times of globalization 5 Conclusion and discussion : changed conditions of responsibility in modern times.

  19. Study on time characteristics of fast time response inorganic scintillator CeF3

    International Nuclear Information System (INIS)

    Hu Mengchun; Zhou Dianzhong; Guo Cun; Ye Wenying

    2003-01-01

    The cerium fluoride (CeF 3 ) is a kind of new fast time response inorganic scintillator. The physical characteristics of CeF 3 are well suitable for detection of domestic pulse γ-rays. The time response of detector composed by phototube with CeF 3 are measured by use of the pulse radiation source with rise time about 0.8 ns, and FWHM time 1.5-2.2 ns. Experiment results show that the rise time is less than 2 ns, FWHM time is about 10 ns, fall time is about 60 ns, average decay time constant is 20-30 ns, respectively for CeF 3

  20. Conceptual question response times in Peer Instruction classrooms

    Directory of Open Access Journals (Sweden)

    Kelly Miller

    2014-08-01

    Full Text Available Classroom response systems are widely used in interactive teaching environments as a way to engage students by asking them questions. Previous research on the time taken by students to respond to conceptual questions has yielded insights on how students think and change conceptions. We measure the amount of time students take to respond to in-class, conceptual questions [ConcepTests (CTs] in two introductory physics courses taught using Peer Instruction and use item response theory to determine the difficulty of the CTs. We examine response time differences between correct and incorrect answers both before and after the peer discussion for CTs of varying difficulty. We also determine the relationship between response time and student performance on a standardized test of incoming physics knowledge, precourse self-efficacy, and gender. Our data reveal three results of interest. First, response time for correct answers is significantly faster than for incorrect answers, both before and after peer discussion, especially for easy CTs. Second, students with greater incoming physics knowledge and higher self-efficacy respond faster in both rounds. Third, there is no gender difference in response rate after controlling for incoming physics knowledge scores, although males register significantly more attempts before committing to a final answer than do female students. These results provide insight into effective CT pacing during Peer Instruction. In particular, in order to maintain a pace that keeps everyone engaged, students should not be given too much time to respond. When around 80% of the answers are in, the ratio of correct to incorrect responses rapidly approaches levels indicating random guessing and instructors should close the poll.

  1. A time-domain method to generate artificial time history from a given reference response spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Gang Sik [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Song, Oh Seop [Dept. of Mechanical Engineering, Chungnam National University, Daejeon (Korea, Republic of)

    2016-06-15

    Seismic qualification by test is widely used as a way to show the integrity and functionality of equipment that is related to the overall safety of nuclear power plants. Another means of seismic qualification is by direct integration analysis. Both approaches require a series of time histories as an input. However, in most cases, the possibility of using real earthquake data is limited. Thus, artificial time histories are widely used instead. In many cases, however, response spectra are given. Thus, most of the artificial time histories are generated from the given response spectra. Obtaining the response spectrum from a given time history is straightforward. However, the procedure for generating artificial time histories from a given response spectrum is difficult and complex to understand. Thus, this paper presents a simple time-domain method for generating a time history from a given response spectrum; the method was shown to satisfy conditions derived from nuclear regulatory guidance.

  2. A time-domain method to generate artificial time history from a given reference response spectrum

    International Nuclear Information System (INIS)

    Shin, Gang Sik; Song, Oh Seop

    2016-01-01

    Seismic qualification by test is widely used as a way to show the integrity and functionality of equipment that is related to the overall safety of nuclear power plants. Another means of seismic qualification is by direct integration analysis. Both approaches require a series of time histories as an input. However, in most cases, the possibility of using real earthquake data is limited. Thus, artificial time histories are widely used instead. In many cases, however, response spectra are given. Thus, most of the artificial time histories are generated from the given response spectra. Obtaining the response spectrum from a given time history is straightforward. However, the procedure for generating artificial time histories from a given response spectrum is difficult and complex to understand. Thus, this paper presents a simple time-domain method for generating a time history from a given response spectrum; the method was shown to satisfy conditions derived from nuclear regulatory guidance

  3. Use of Response Time for Measuring Cognitive Ability

    Directory of Open Access Journals (Sweden)

    Patrick C. Kyllonen

    2016-11-01

    Full Text Available The purpose of this paper is to review some of the key literature on response time as it has played a role in cognitive ability measurement, providing a historical perspective as well as covering current research. We discuss the speed-level distinction, dimensions of speed and level in cognitive abilities frameworks, speed–accuracy tradeoff, approaches to addressing speed–accuracy tradeoff, analysis methods, particularly item response theory-based, response time models from cognitive psychology (ex-Gaussian function, and the diffusion model, and other uses of response time in testing besides ability measurement. We discuss several new methods that can be used to provide greater insight into the speed and level aspects of cognitive ability and speed–accuracy tradeoff decisions. These include item-level time limits, the use of feedback (e.g., CUSUMs, explicit scoring rules that combine speed and accuracy information (e.g., count down timing, and cognitive psychology models. We also review some of the key psychometric advances in modeling speed and level, which combine speed and ability measurement, address speed–accuracy tradeoff, allow for distinctions between response times on items responded to correctly and incorrectly, and integrate psychometrics with information-processing modeling. We suggest that the application of these models and tools is likely to advance both the science and measurement of human abilities for theory and applications.

  4. A heteroscedastic generalized linear model with a non-normal speed factor for responses and response times.

    Science.gov (United States)

    Molenaar, Dylan; Bolsinova, Maria

    2017-05-01

    In generalized linear modelling of responses and response times, the observed response time variables are commonly transformed to make their distribution approximately normal. A normal distribution for the transformed response times is desirable as it justifies the linearity and homoscedasticity assumptions in the underlying linear model. Past research has, however, shown that the transformed response times are not always normal. Models have been developed to accommodate this violation. In the present study, we propose a modelling approach for responses and response times to test and model non-normality in the transformed response times. Most importantly, we distinguish between non-normality due to heteroscedastic residual variances, and non-normality due to a skewed speed factor. In a simulation study, we establish parameter recovery and the power to separate both effects. In addition, we apply the model to a real data set. © 2017 The Authors. British Journal of Mathematical and Statistical Psychology published by John Wiley & Sons Ltd on behalf of British Psychological Society.

  5. Time response of temperature sensors using neural networks

    International Nuclear Information System (INIS)

    Santos, Roberto Carlos dos

    2010-01-01

    In a PWR nuclear power plant, the primary coolant temperature and feedwater temperature are measured using RTDs (Resistance Temperature Detectors). These RTDs typically feed the plant's control and safety systems and must, therefore, be very accurate and have good dynamic performance. The response time of RTDs is characterized by a single parameter called the Plunge Time Constant defined as the time it takes the sensor output to achieve 63.2 percent of its final value after a step change in temperature. Nuclear reactor service conditions are difficult to reproduce in the laboratory, and an in-situ test method called LCSR (Loop Current Step Response) test was developed to measure remotely the response time of RTDs. >From this test, the time constant of the sensor is identified by means of the LCSR transformation that involves the dynamic response modal time constants determination using a nodal heat-transfer model. This calculation is not simple and requires specialized personnel. For this reason an Artificial Neural Network has been developed to predict the time constant of RTD from LCSR test transient. It eliminates the transformations involved in the LCSR application. A series of LCSR tests on RTDs generates the response transients of the sensors, the input data of the networks. Plunge tests are used to determine the time constants of the RTDs, the desired output of the ANN, trained using these sets of input/output data. This methodology was firstly applied to theoretical data simulating 10 RTDs with different time constant values, resulting in an average error of about 0.74 %. Experimental data from three different RTDs was used to predict time constant resulting in a maximum error of 3,34 %. The time constants values predicted from ANN were compared with those obtained from traditional way resulting in an average error of about 18 % and that shows the network is able to predict accurately the sensor time constant. (author)

  6. Investigations on response time of magnetorheological elastomer under compression mode

    Science.gov (United States)

    Zhu, Mi; Yu, Miao; Qi, Song; Fu, Jie

    2018-05-01

    For efficient fast control of vibration system with magnetorheological elastomer (MRE)-based smart device, the response time of MRE material is the key parameter which directly affects the control performance of the vibration system. For a step coil current excitation, this paper proposed a Maxwell behavior model with time constant λ to describe the normal force response of MRE, and the response time of MRE was extracted through the separation of coil response time. Besides, the transient responses of MRE under compression mode were experimentally investigated, and the effects of (i) applied current, (ii) particle distribution and (iii) compressive strain on the response time of MRE were addressed. The results revealed that the three factors can affect the response characteristic of MRE quite significantly. Besides the intrinsic importance for contributing to the response evaluation and effective design of MRE device, this study may conduce to the optimal design of controller for MRE control system.

  7. Cognitive Reflection, Decision Biases, and Response Times

    Directory of Open Access Journals (Sweden)

    Carlos Alos-Ferrer

    2016-09-01

    Full Text Available We present novel evidence on decision times and personality traits in standard questions from the decision-making literature where responses are relatively slow (medians around half a minute or above. To this end, we measured decision times in a number of incentivized, framed items (decisions from description including the Cognitive Reflection Test, two additional questions following the same logic, and a number of classic questions used to study decision biases in probability judgments (base-rate neglect, the conjunction fallacy, and the ratio bias. All questions create a conflict between an intuitive process and more deliberative thinking. For each item, we then created a non-conflict version by either making the intuitive impulse correct (resulting in an alignment question, shutting it down (creating a neutral question, or making it dominant (creating a heuristic question. For CRT questions, the differences in decision times are as predicted by dual-process theories, with alignment and heuristic variants leading to faster responses and neutral questions to slower responses than the original, conflict questions. For decision biases (where responses are slower, evidence is mixed. To explore the possible influence of personality factors on both choices and decision times, we used standard personality scales including the Rational-Experiential Inventory and the Big Five, and used the mas controls in regression analysis.

  8. TWODEE-2/MOD3, 2-D Time-Dependent Fuel Elements Thermal Analysis after PWR LOCA

    International Nuclear Information System (INIS)

    Lauben, G. N.

    2001-01-01

    1 - Description of problem or function: WREM-TOODEE2 is a two- dimensional, time-dependent, fuel-element thermal analysis program. Its primary purpose is to evaluate fuel-element thermal response during post-LOCA refill and reflood in a pressurized water reactor (PWR). 2 - Method of solution: TOODEE2 calculations are carried out in a two-dimensional mesh region defined in slab or cylindrical geometry by orthogonal grid lines. Coordinates which form order pairs are labeled x-y in slab geometry, and those in cylindrical geometry are labeled r-z for the axisymmetric case and r-theta for the polar case. Conduction and radiation are the only heat transfer mechanisms assumed within the boundaries of the mesh region. Convective and boiling heat transfer mechanisms are assumed at the boundaries. The program numerically solves the two-dimensional, time-dependent, heat conduction equation within the mesh region. 3 - Restrictions on the complexity of the problem: WREM-TOODEE2 considers only axisymmetric geometry although the equations for slab and polar geometry are included in the program

  9. Timing criteria for supplemental BWR emergency response equipment

    International Nuclear Information System (INIS)

    Bickel, John H.

    2015-01-01

    The Great Tohuku Earthquake and subsequent Tsunami represented a double failure event which destroyed offsite power connections to Fukushima-Daiichi site and then destroyed on-site electrical systems needed to run decay heat removal systems. The accident could have been mitigated had there been supplemental portable battery chargers, supplemental pumps, and in-place piping connections to provide alternate decay heat removal. In response to this event in the USA, two national response centers, one in Memphis, Tennessee, and another in Phoenix, Arizona, will begin operation. They will be able to dispatch supplemental emergency response equipment to any nuclear plant in the U.S. within 24 hours. In order to define requirements for supplemental nuclear power plant emergency response equipment maintained onsite vs. in a regional support center it is necessary to confirm: (a) the earliest time such equipment might be needed depending on the specific scenario, (b) the nominal time to move the equipment from a storage location either on-site or within the region of a nuclear power plant, and (c) the time required to connect in the supplemental equipment to use it. This paper describes an evaluation process for a BWR-4 with a Mark I Containment starting with: (a) severe accident simulation to define best estimate times available for recovery based on the specific scenario, (b) identify the key supplemental response equipment needed at specific times to accomplish recovery of key safety functions, and (c) evaluate what types of equipment should be warehoused on-site vs. in regional response centers. (authors)

  10. Faktor Risiko Pencemaran Mikrobiologi pada Air Minum Isi Ulang di Kabupaten Tegal

    Directory of Open Access Journals (Sweden)

    Cecilia Sri Rahayu

    2013-12-01

    station using ineligible standard water of MPN coliform had risk 5,6 times compared to using standard water. Product drinking water from drinking water refilling station with quality of filtration that was not good had up risk 34 times compared to if the quality of filtration was good Product drinking water from drinking water refilling station with quality of desinfection which was not good had risk 9,2 times compared to if the good quality of desinfection. Recomendation :The owners of the drinking water refilling station was obliged to guarantee water quality to drink produced by it is safe for health. Public expected to be more attentively in consuming water product from drinking water refilling station. Health Department needs more increases construction and observation to drinking water refilling station. Keywords : Microbiological Contamination of Drinking Water Refilling,Tegal Regency

  11. Validation of a simple response-time measure of listening effort

    NARCIS (Netherlands)

    Pals, Carina; Sarampalis, Anastasios; van Rijn, Hedderik; Başkent, Deniz

    This study compares two response-time measures of listening effort that can be combined with a clinical speech test for a more comprehensive evaluation of total listening experience; verbal response times to auditory stimuli (RTaud) and response times to a visual task (RTsvis) in a dual- task

  12. A Study of Improving Response Time Verification Method for Pressure Transmitters

    International Nuclear Information System (INIS)

    Lee, Jungyang; Ha, Jaehong; Jung, Insoo; Jo, Junghee; Kim, Hangbae

    2007-01-01

    Technical Specifications (TS) of OPR1000 type nuclear power plants in Korea require pressure sensor response time testing (RTT) to ensure sensor performance per assumption in plant safety analyses. However, the need for pressure sensor response time testing is not clear because the nominal sensor response times are in the order of milliseconds while overall loop response time limits being from several seconds to tens of seconds. Additionally, response time testing does not appear to identify response time degradation or failures. Consequently, the need for this testing has been questioned, and a study to determine if response time testing is necessary to justify the assumptions in plant safety analyses in the United States has been conducted and NRC has approved to remove the test requirements for them. A similar study was conducted for OPR1000 type nuclear power plants and the results are presented here

  13. Assessment of medication adherence and responsible use of isotretinoin and contraception through Belgian community pharmacies by using pharmacy refill data

    Directory of Open Access Journals (Sweden)

    Biset N

    2018-01-01

    attempts increased (29.8% for the second attempt and 19.8% for more than two attempts. Men seemed more adherent than women, and a weak negative correlation between adherence and age was observed. The adherence data of isotretinoin and contraception were independent. The median persistence for isotretinoin treatment was 139 days (interquartile range 71–209 and was higher for men. Among women between 12 and 21 years old taking isotretinoin, 63.8% received at least one contraceptive prescription. However, 15.7% of women taking isotretinoin adhered to the use of contraception 1 month before, during, and 1 month after treatment. Conclusion: Medication adherence to isotretinoin and contraception and compliance with the isotretinoin safety recommendation could be improved. Health service interventions, using pharmacy refill data, should be delivered to ensure patient safety and strict adherence to contraception when under isotretinoin treatment. Keywords: medication possession ratio, persistence, patient safety, pregnancy prevention program

  14. Peripheral visual response time and visual display layout

    Science.gov (United States)

    Haines, R. F.

    1974-01-01

    Experiments were performed on a group of 42 subjects in a study of their peripheral visual response time to visual signals under positive acceleration, during prolonged bedrest, at passive 70 deg headup body lift, under exposures to high air temperatures and high luminance levels, and under normal stress-free laboratory conditions. Diagrams are plotted for mean response times to white, red, yellow, green, and blue stimuli under different conditions.

  15. Calibration of the time response functions of a quenched plastic scintillator for neutron time of flight

    CERN Document Server

    Chen, J B; Peng, H S; Tang, C H; Zhang, B H; Ding, Y K; Chen, M; Chen, H S; Li, C G; Wen, T S; Yu, R Z

    2002-01-01

    The time response functions of an ultrafast quenched plastic scintillation detector used to measure neutron time of flight spectra were calibrated by utilizing cosmic rays and implosion neutrons from DT-filled capsules at the Shenguang II laser facility. These sources could be regarded as delta function pulses due to their much narrower time widths than those of the time response functions of the detection system. The results showed that the detector responses to DT neutrons and to cosmic rays were 1.18 and 0.96 ns FWHM, respectively.

  16. A Bivariate Generalized Linear Item Response Theory Modeling Framework to the Analysis of Responses and Response Times.

    Science.gov (United States)

    Molenaar, Dylan; Tuerlinckx, Francis; van der Maas, Han L J

    2015-01-01

    A generalized linear modeling framework to the analysis of responses and response times is outlined. In this framework, referred to as bivariate generalized linear item response theory (B-GLIRT), separate generalized linear measurement models are specified for the responses and the response times that are subsequently linked by cross-relations. The cross-relations can take various forms. Here, we focus on cross-relations with a linear or interaction term for ability tests, and cross-relations with a curvilinear term for personality tests. In addition, we discuss how popular existing models from the psychometric literature are special cases in the B-GLIRT framework depending on restrictions in the cross-relation. This allows us to compare existing models conceptually and empirically. We discuss various extensions of the traditional models motivated by practical problems. We also illustrate the applicability of our approach using various real data examples, including data on personality and cognitive ability.

  17. On the Relationship Between Transfer Function-derived Response Times and Hydrograph Analysis Timing Parameters: Are there Similarities?

    Science.gov (United States)

    Bansah, S.; Ali, G.; Haque, M. A.; Tang, V.

    2017-12-01

    The proportion of precipitation that becomes streamflow is a function of internal catchment characteristics - which include geology, landscape characteristics and vegetation - and influence overall storage dynamics. The timing and quantity of water discharged by a catchment are indeed embedded in event hydrographs. Event hydrograph timing parameters, such as the response lag and time of concentration, are important descriptors of how long it takes the catchment to respond to input precipitation and how long it takes the latter to filter through the catchment. However, the extent to which hydrograph timing parameters relate to average response times derived from fitting transfer functions to annual hydrographs is unknown. In this study, we used a gamma transfer function to determine catchment average response times as well as event-specific hydrograph parameters across a network of eight nested watersheds ranging from 0.19 km2 to 74.6 km2 prairie catchments located in south central Manitoba (Canada). Various statistical analyses were then performed to correlate average response times - estimated using the parameters of the fitted gamma transfer function - to event-specific hydrograph parameters. Preliminary results show significant interannual variations in response times and hydrograph timing parameters: the former were in the order of a few hours to days, while the latter ranged from a few days to weeks. Some statistically significant relationships were detected between response times and event-specific hydrograph parameters. Future analyses will involve the comparison of statistical distributions of event-specific hydrograph parameters with that of runoff response times and baseflow transit times in order to quantity catchment storage dynamics across a range of temporal scales.

  18. Planck 2013 results. VII. HFI time response and beams

    CERN Document Server

    Ade, P A R; Armitage-Caplan, C; Arnaud, M; Ashdown, M; Atrio-Barandela, F; Aumont, J; Baccigalupi, C; Banday, A J; Barreiro, R B; Battaner, E; Benabed, K; Benoît, A; Benoit-Lévy, A; Bernard, J -P; Bersanelli, M; Bielewicz, P; Bobin, J; Bock, J J; Bond, J R; Borrill, J; Bouchet, F R; Bowyer, J W; Bridges, M; Bucher, M; Burigana, C; Cardoso, J -F; Catalano, A; Challinor, A; Chamballu, A; Chary, R -R; Chiang, L -Y; Chiang, H C; Christensen, P R; Church, S; Clements, D L; Colombi, S; Colombo, L P L; Couchot, F; Coulais, A; Crill, B P; Curto, A; Cuttaia, F; Danese, L; Davies, R D; de Bernardis, P; de Rosa, A; de Zotti, G; Delabrouille, J; Delouis, J -M; Désert, F -X; Diego, J M; Dole, H; Donzelli, S; Doré, O; Douspis, M; Dunkley, J; Dupac, X; Efstathiou, G; Enßlin, T A; Eriksen, H K; Finelli, F; Forni, O; Frailis, M; Fraisse, A A; Franceschi, E; Galeotta, S; Ganga, K; Giard, M; Giraud-Héraud, Y; González-Nuevo, J; Górski, K M; Gratton, S; Gregorio, A; Gruppuso, A; Gudmundsson, J E; Haissinski, J; Hansen, F K; Hanson, D; Harrison, D; Henrot-Versillé, S; Hernández-Monteagudo, C; Herranz, D; Hildebrandt, S R; Hivon, E; Hobson, M; Holmes, W A; Hornstrup, A; Hou, Z; Hovest, W; Huffenberger, K M; Jaffe, T R; Jaffe, A H; Jones, W C; Juvela, M; Keihänen, E; Keskitalo, R; Kisner, T S; Kneissl, R; Knoche, J; Knox, L; Kunz, M; Kurki-Suonio, H; Lagache, G; Lamarre, J -M; Lasenby, A; Laureijs, R J; Lawrence, C R; Leonardi, R; Leroy, C; Lesgourgues, J; Liguori, M; Lilje, P B; Linden-Vørnle, M; López-Caniego, M; Lubin, P M; Macías-Pérez, J F; MacTavish, C J; Maffei, B; Mandolesi, N; Maris, M; Marshall, D J; Martin, P G; Martínez-González, E; Masi, S; Matarrese, S; Matsumura, T; Matthai, F; Mazzotta, P; McGehee, P; Melchiorri, A; Mendes, L; Mennella, A; Migliaccio, M; Mitra, S; Miville-Deschênes, M -A; Moneti, A; Montier, L; Morgante, G; Mortlock, D; Munshi, D; Murphy, J A; Naselsky, P; Nati, F; Natoli, P; Netterfield, C B; Nørgaard-Nielsen, H U; Noviello, F; Novikov, D; Novikov, I; Osborne, S; Oxborrow, C A; Paci, F; Pagano, L; Pajot, F; Paoletti, D; Pasian, F; Patanchon, G; Perdereau, O; Perotto, L; Perrotta, F; Piacentini, F; Piat, M; Pierpaoli, E; Pietrobon, D; Plaszczynski, S; Pointecouteau, E; Polegre, A M; Polenta, G; Ponthieu, N; Popa, L; Poutanen, T; Pratt, G W; Prézeau, G; Prunet, S; Puget, J -L; Rachen, J P; Reinecke, M; Remazeilles, M; Renault, C; Ricciardi, S; Riller, T; Ristorcelli, I; Rocha, G; Rosset, C; Roudier, G; Rowan-Robinson, M; Rusholme, B; Sandri, M; Santos, D; Sauvé, A; Savini, G; Shellard, E P S; Spencer, L D; Starck, J -L; Stolyarov, V; Stompor, R; Sudiwala, R; Sureau, F; Sutton, D; Suur-Uski, A -S; Sygnet, J -F; Tauber, J A; Tavagnacco, D; Terenzi, L; Tomasi, M; Tristram, M; Tucci, M; Umana, G; Valenziano, L; Valiviita, J; Van Tent, B; Vielva, P; Villa, F; Vittorio, N; Wade, L A; Wandelt, B D; Yvon, D; Zacchei, A; Zonca, A

    2014-01-01

    This paper characterizes the effective beams,the effective beam window functions and the associated errors for the Planck HFI detectors. The effective beam is the angular response including the effect of the optics,detectors,data processing and the scan strategy. The window function is the representation of this beam in the harmonic domain which is required to recover an unbiased measurement of the CMB angular power spectrum. The HFI is a scanning instrument and its effective beams are the convolution of: (a) the optical response of the telescope and feeds;(b)the processing of the time-ordered data and deconvolution of the bolometric and electronic time response; and (c) the merging of several surveys to produce maps. The time response functions are measured using observations of Jupiter and Saturn and by minimizing survey difference residuals. The scanning beam is the post-deconvolution angular response of the instrument, and is characterized with observations of Mars. The main beam solid angles are determin...

  19. Modeling operators' emergency response time for chemical processing operations.

    Science.gov (United States)

    Murray, Susan L; Harputlu, Emrah; Mentzer, Ray A; Mannan, M Sam

    2014-01-01

    Operators have a crucial role during emergencies at a variety of facilities such as chemical processing plants. When an abnormality occurs in the production process, the operator often has limited time to either take corrective actions or evacuate before the situation becomes deadly. It is crucial that system designers and safety professionals can estimate the time required for a response before procedures and facilities are designed and operations are initiated. There are existing industrial engineering techniques to establish time standards for tasks performed at a normal working pace. However, it is reasonable to expect the time required to take action in emergency situations will be different than working at a normal production pace. It is possible that in an emergency, operators will act faster compared to a normal pace. It would be useful for system designers to be able to establish a time range for operators' response times for emergency situations. This article develops a modeling approach to estimate the time standard range for operators taking corrective actions or following evacuation procedures in emergency situations. This will aid engineers and managers in establishing time requirements for operators in emergency situations. The methodology used for this study combines a well-established industrial engineering technique for determining time requirements (predetermined time standard system) and adjustment coefficients for emergency situations developed by the authors. Numerous videos of workers performing well-established tasks at a maximum pace were studied. As an example, one of the tasks analyzed was pit crew workers changing tires as quickly as they could during a race. The operations in these videos were decomposed into basic, fundamental motions (such as walking, reaching for a tool, and bending over) by studying the videos frame by frame. A comparison analysis was then performed between the emergency pace and the normal working pace operations

  20. The Effect of Police Response Time on Crime Detection

    DEFF Research Database (Denmark)

    Blanes i Vidal, Jordi; Kirchmaier, Tom

    preferred estimate, a 10% increase in response time leads to a 4.6 percentage points decrease in the likelihood of detection. A faster response time also decreases the number of days that it takes for the police to detect a crime, conditional on eventual detection. We find stronger effects for thefts than...

  1. Response times in a two-node queueing network with feedback

    NARCIS (Netherlands)

    van der Mei, R.D.; Gijsen, B.M.M.; in 't Veld, N.; van den Berg, J.L.

    2002-01-01

    The study presented in this paper is motivated by the performance analysis of response times in distributed information systems, where transactions are handled by iterative server and database actions. We model system response times as sojourn times in a two-node open queueing network with a

  2. Response times in a two-node queueing network with feedback

    NARCIS (Netherlands)

    van der Mei, R.D.; Gijsen, B.M.M.; Gijsen, B.M.M.; in 't Veld, N.; van den Berg, Hans Leo

    The study presented in this paper is motivated by the performance analysis of response times in distributed information systems, where transactions are handled by iterative server and database actions. We model system response times as sojourn times in a two-node open queueing network with a

  3. Improvement in MFTF data base system response times

    International Nuclear Information System (INIS)

    Lang, N.C.; Nelson, B.C.

    1983-01-01

    The Supervisory Control and Diagnostic System for the Mirror Fusion Test Facility (MFTF) has been designed as an event driven system. To this end we have designed a data base notification facility in which a task can request that it be loaded and started whenever an element in the data base is changed beyond some user defined range. Our initial implementation of the notify facility exhibited marginal response times whenever a data base table with a large number of outstanding notifies was written into. In this paper we discuss the sources of the slow response and describe in detail a new structure for the list of notifies which minimizes search time resulting in significantly faster response

  4. Uncertainty analysis of accident notification time and emergency medical service response time in work zone traffic accidents.

    Science.gov (United States)

    Meng, Qiang; Weng, Jinxian

    2013-01-01

    Taking into account the uncertainty caused by exogenous factors, the accident notification time (ANT) and emergency medical service (EMS) response time were modeled as 2 random variables following the lognormal distribution. Their mean values and standard deviations were respectively formulated as the functions of environmental variables including crash time, road type, weekend, holiday, light condition, weather, and work zone type. Work zone traffic accident data from the Fatality Analysis Report System between 2002 and 2009 were utilized to determine the distributions of the ANT and the EMS arrival time in the United States. A mixed logistic regression model, taking into account the uncertainty associated with the ANT and the EMS response time, was developed to estimate the risk of death. The results showed that the uncertainty of the ANT was primarily influenced by crash time and road type, whereas the uncertainty of EMS response time is greatly affected by road type, weather, and light conditions. In addition, work zone accidents occurring during a holiday and in poor light conditions were found to be statistically associated with a longer mean ANT and longer EMS response time. The results also show that shortening the ANT was a more effective approach in reducing the risk of death than the EMS response time in work zones. To shorten the ANT and the EMS response time, work zone activities are suggested to be undertaken during non-holidays, during the daytime, and in good weather and light conditions.

  5. Preoperative pain measures ineffective in outpatient abdominal surgeries.

    Science.gov (United States)

    Wright, Robert; Wright, Julia; Perry, Kyler; Wright, Daniel

    2018-05-01

    The multimodality addition of preoperative gabapentin, acetaminophen, and celecoxib (GAC) and postoperative TENS has been recommended to diminish narcotics. We predict that GAC-TENS implementation will reduce recovery room time, improve pain control, reduce narcotic refills, and demonstrate usefulness of TENS treatment. A prospective study compared a control group of patients not utilizing the GAC-TENS protocol during 2015 to patients using the GAC-TENS protocol during 2016. There was less recovery room time in the control group compared to the protocol group. Postoperative day one pain control was similar between the groups. Less refills were noted. TENS unit satisfaction level was rated "very helpful" by 63% of patients. The results call into question the efficacy of the American Pain Society recommendations as they increase time in recovery room but do not decrease the quantity of narcotics used in the recovery room, nor do they improve pain satisfaction responses. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Distinguishing Fast and Slow Processes in Accuracy - Response Time Data.

    Directory of Open Access Journals (Sweden)

    Frederik Coomans

    Full Text Available We investigate the relation between speed and accuracy within problem solving in its simplest non-trivial form. We consider tests with only two items and code the item responses in two binary variables: one indicating the response accuracy, and one indicating the response speed. Despite being a very basic setup, it enables us to study item pairs stemming from a broad range of domains such as basic arithmetic, first language learning, intelligence-related problems, and chess, with large numbers of observations for every pair of problems under consideration. We carry out a survey over a large number of such item pairs and compare three types of psychometric accuracy-response time models present in the literature: two 'one-process' models, the first of which models accuracy and response time as conditionally independent and the second of which models accuracy and response time as conditionally dependent, and a 'two-process' model which models accuracy contingent on response time. We find that the data clearly violates the restrictions imposed by both one-process models and requires additional complexity which is parsimoniously provided by the two-process model. We supplement our survey with an analysis of the erroneous responses for an example item pair and demonstrate that there are very significant differences between the types of errors in fast and slow responses.

  7. Measuring older adults' sedentary time: reliability, validity, and responsiveness.

    Science.gov (United States)

    Gardiner, Paul A; Clark, Bronwyn K; Healy, Genevieve N; Eakin, Elizabeth G; Winkler, Elisabeth A H; Owen, Neville

    2011-11-01

    With evidence that prolonged sitting has deleterious health consequences, decreasing sedentary time is a potentially important preventive health target. High-quality measures, particularly for use with older adults, who are the most sedentary population group, are needed to evaluate the effect of sedentary behavior interventions. We examined the reliability, validity, and responsiveness to change of a self-report sedentary behavior questionnaire that assessed time spent in behaviors common among older adults: watching television, computer use, reading, socializing, transport and hobbies, and a summary measure (total sedentary time). In the context of a sedentary behavior intervention, nonworking older adults (n = 48, age = 73 ± 8 yr (mean ± SD)) completed the questionnaire on three occasions during a 2-wk period (7 d between administrations) and wore an accelerometer (ActiGraph model GT1M) for two periods of 6 d. Test-retest reliability (for the individual items and the summary measure) and validity (self-reported total sedentary time compared with accelerometer-derived sedentary time) were assessed during the 1-wk preintervention period, using Spearman (ρ) correlations and 95% confidence intervals (CI). Responsiveness to change after the intervention was assessed using the responsiveness statistic (RS). Test-retest reliability was excellent for television viewing time (ρ (95% CI) = 0.78 (0.63-0.89)), computer use (ρ (95% CI) = 0.90 (0.83-0.94)), and reading (ρ (95% CI) = 0.77 (0.62-0.86)); acceptable for hobbies (ρ (95% CI) = 0.61 (0.39-0.76)); and poor for socializing and transport (ρ < 0.45). Total sedentary time had acceptable test-retest reliability (ρ (95% CI) = 0.52 (0.27-0.70)) and validity (ρ (95% CI) = 0.30 (0.02-0.54)). Self-report total sedentary time was similarly responsive to change (RS = 0.47) as accelerometer-derived sedentary time (RS = 0.39). The summary measure of total sedentary time has good repeatability and modest validity and is

  8. Hierarchical Bayes Models for Response Time Data

    Science.gov (United States)

    Craigmile, Peter F.; Peruggia, Mario; Van Zandt, Trisha

    2010-01-01

    Human response time (RT) data are widely used in experimental psychology to evaluate theories of mental processing. Typically, the data constitute the times taken by a subject to react to a succession of stimuli under varying experimental conditions. Because of the sequential nature of the experiments there are trends (due to learning, fatigue,…

  9. [Construction of the Time Management Scale and examination of the influence of time management on psychological stress response].

    Science.gov (United States)

    Imura, Tomoya; Takamura, Masahiro; Okazaki, Yoshihiro; Tokunaga, Satoko

    2016-10-01

    We developed a scale to measure time management and assessed its reliability and validity. We then used this scale to examine the impact of time management on psychological stress response. In Study 1-1, we developed the scale and assessed its internal consistency and criterion-related validity. Findings from a factor analysis revealed three elements of time management, “time estimation,” “time utilization,” and “taking each moment as it comes.” In Study 1-2, we assessed the scale’s test-retest reliability. In Study 1-3, we assessed the validity of the constructed scale. The results indicate that the time management scale has good reliability and validity. In Study 2, we performed a covariance structural analysis to verify our model that hypothesized that time management influences perceived control of time and psychological stress response, and perceived control of time influences psychological stress response. The results showed that time estimation increases the perceived control of time, which in turn decreases stress response. However, we also found that taking each moment as it comes reduces perceived control of time, which in turn increases stress response.

  10. Comparison of LMFBR piping response obtained using response spectrum and time history methods

    International Nuclear Information System (INIS)

    Hulbert, G.M.

    1981-04-01

    The dynamic response to a seismic event is calculated for a piping system using a response spectrum analysis method and two time history analysis methods. The results from the analytical methods are compared to identify causes for the differences between the sets of analytical results. Comparative methods are also presented which help to gain confidence in the accuracy of the analytical methods in predicting piping system structure response during seismic events

  11. Walter Reed Army Medical Center's Internet-based electronic health portal.

    Science.gov (United States)

    Abbott, Kevin C; Boocks, Carl E; Sun, Zhengyi; Boal, Thomas R; Poropatich, Ronald K

    2003-12-01

    Use of the World Wide Web (WWW) and electronic media to facilitate medical care has been the subject of many reports in the popular press. However, few reports have documented the results of implementing electronic health portals for essential medical tasks, such as prescription refills and appointments. At Walter Reed Army Medical Center, "Search & Learn" medical information, Internet-based prescription refills and patient appointments were established in January 2001. A multiphase retrospective analysis was conducted to determine the use of the "Search & Learn" medical information and the relative number of prescription refills and appointments conducted via the WWW compared with conventional methods. From January 2001 to May 2002, there were 34,741 refills and 819 appointments made over the Internet compared with 2,275,112 refills and approximately 500,000 appointments made conventionally. WWW activity accounted for 1.52% of refills and 0.16% of appointments. There was a steady increase in this percentage over the time of the analysis. In April of 2002, the monthly average of online refills had risen to 4.57% and online appointments were at 0.27%. Online refills were projected to account for 10% of all prescriptions in 2 years. The "Search & Learn" medical information portion of our web site received 147,429 unique visits during this same time frame, which was an average of 326 visitors per day. WWW-based methods of conducting essential medical tasks accounted for a small but rapidly increasing percentage of total activity at Walter Reed Army Medical Center. Subsequent phases of analysis will assess demographic and geographic factors and aid in the design of future systems to increase use of the Internet-based systems.

  12. Modeling an Application's Theoretical Minimum and Average Transactional Response Times

    Energy Technology Data Exchange (ETDEWEB)

    Paiz, Mary Rose [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-04-01

    The theoretical minimum transactional response time of an application serves as a ba- sis for the expected response time. The lower threshold for the minimum response time represents the minimum amount of time that the application should take to complete a transaction. Knowing the lower threshold is beneficial in detecting anomalies that are re- sults of unsuccessful transactions. On the converse, when an application's response time falls above an upper threshold, there is likely an anomaly in the application that is causing unusual performance issues in the transaction. This report explains how the non-stationary Generalized Extreme Value distribution is used to estimate the lower threshold of an ap- plication's daily minimum transactional response time. It also explains how the seasonal Autoregressive Integrated Moving Average time series model is used to estimate the upper threshold for an application's average transactional response time.

  13. Time-based MRPC detector response simulations for the CBM time-of-flight system

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Christian; Herrmann, Norbert [Physikalisches Institut und Fakultaet fuer Physik und Astronomie, Ruprecht-Karls-Universitaet Heidelberg (Germany); Collaboration: CBM-Collaboration

    2016-07-01

    The design goal of the future Compressed Baryonic Matter (CBM) experiment is to measure rare probes of dense strongly interacting matter with an unprecedented accuracy. Target interaction rates of up to 10 MHz need to be processed by the detector. The time-of-flight (TOF) wall of CBM which should provide hadron identification at particle fluxes of up to a few tens of kHz/cm{sup 2} is composed of high-resolution timing multi-gap resistive plate chambers (MRPCs). Due to the self-triggered digitization and readout scheme of CBM comprising online event reconstruction preparatory Monte Carlo (MC) transport and response simulations including the MRPC array need to be carried out in a time-based fashion. While in an event-based simulation mode interference between MC tracks in a detector volume owing to rate effects or electronics dead time is confined to a single event, time-based response simulations need to take into account track pile-up and interference across events. A proposed time-based digitizer class for CBM-TOF within the CbmRoot software framework is presented.

  14. A Box-Cox normal model for response times

    NARCIS (Netherlands)

    Klein Entink, R.H.; Fox, J.P.; Linden, W.J. van der

    2009-01-01

    The log-transform has been a convenient choice in response time modelling on test items. However, motivated by a dataset of the Medical College Admission Test where the lognormal model violated the normality assumption, the possibilities of the broader class of Box–Cox transformations for response

  15. Next-Generation Library Catalogs and the Problem of Slow Response Time

    Directory of Open Access Journals (Sweden)

    Margaret Brown-Sica

    2010-12-01

    Full Text Available Response time as defined for this study is the time that it takes for all files that constitute a single webpage to travel across the Internet from a Web server to the end user’s browser. In this study, the authors tested response times on queries for identical items in five different library catalogs, one of them a next-generation (NextGen catalog. The authors also discuss acceptable response time and how it may affect the discovery process. They suggest that librarians and vendors should develop standards for acceptable response time and use it in the product selection and development processes.

  16. Experience with RTD response time testing in nuclear power plants

    International Nuclear Information System (INIS)

    Hashemian, H.M.; Kerlin, T.W.

    1985-01-01

    The reactor coolant temperatures in pressurized water reactors are measured with platinum resistance temperature detectors (RTDs). The information furnished by these RTDs is used for plant protection as well as control. As a part of the plant protection system, the RTDs must respond to temperature changes in a timely fashion. The RTD response time requirements are different for the various plant types. These requirements are specified in the plant technical specifications in terms of an RTd time constant. The current time constant requirements for nuclear plant RTDs varies from 0.5 seconds to 13.0 seconds depending on the type of the plant. Therefore, different types of RTDs are used in different plants to achieve the required time constants. In addition, in-situ response time tests are periodically performed on protective system RTDs to ensure that the in-service time constants are within acceptable limits as the plant is operating. The periodic testing is important because response time degradation may occur while the RTD ages in the process. Recent response time tests in operating plants revealed unacceptable time constants for several protection system RTDs. As a result, these plants had to be shut down to resolve the problem which in one case was due to improper installation and in another case was because of degradation of a thermal compound used in the thermowell

  17. Overeating at dinner time among Japanese workers: Is overeating related to stress response and late dinner times?

    Science.gov (United States)

    Suzuki, Akiko; Sakurazawa, Hirofumi; Fujita, Takanori; Akamatsu, Rie

    2016-06-01

    There are several known risk factors for overeating, including negative feelings and hunger. It was hypothesized that overtime work is associated with stress responses and later dinner times, leading to longer periods of time without eating, and that this, in turn, leads to a strong experience of hunger and consequent overeating at dinner. The aim of this study was to examine relationships among overeating at dinner, stress responses (e.g., fatigue, anxiety, and depression), and dinner times in Japanese male workers. In December 2012, 255 Japanese male workers at a leasing company completed a self-report questionnaire about overeating at dinner, psychological stress responses, physical stress responses, and dinner times. Each worker was sent an email with a link to the questionnaire website, where his answers were collected. Relationships between overeating at dinner and lifestyle issues were investigated using multiple linear regression analysis treating overeating as a dependent variable. Factors related to overeating at dinner included psychological stress response (β = 0.251 p overeating at dinner is related to dinner time in men and to stress responses. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. The response time distribution in a real-time database with optimistic concurrency control

    NARCIS (Netherlands)

    Sassen, S.A.E.; Wal, van der J.

    1996-01-01

    For a real-time shared-memory database with optimistic concurrency control, an approximation for the transaction response time distribution is obtained. The model assumes that transactions arrive at the database according to a Poisson process, that every transaction uses an equal number of

  19. Integrated response and transit time distributions of watersheds by combining hydrograph separation and long-term transit time modeling

    Directory of Open Access Journals (Sweden)

    M. C. Roa-García

    2010-08-01

    Full Text Available We present a new modeling approach analyzing and predicting the Transit Time Distribution (TTD and the Response Time Distribution (RTD from hourly to annual time scales as two distinct hydrological processes. The model integrates Isotope Hydrograph Separation (IHS and the Instantaneous Unit Hydrograph (IUH approach as a tool to provide a more realistic description of transit and response time of water in catchments. Individual event simulations and parameterizations were combined with long-term baseflow simulation and parameterizations; this provides a comprehensive picture of the catchment response for a long time span for the hydraulic and isotopic processes. The proposed method was tested in three Andean headwater catchments to compare the effects of land use on hydrological response and solute transport. Results show that the characteristics of events and antecedent conditions have a significant influence on TTD and RTD, but in general the RTD of the grassland dominated catchment is concentrated in the shorter time spans and has a higher cumulative TTD, while the forest dominated catchment has a relatively higher response distribution and lower cumulative TTD. The catchment where wetlands concentrate shows a flashier response, but wetlands also appear to prolong transit time.

  20. Aircraft Fault Detection Using Real-Time Frequency Response Estimation

    Science.gov (United States)

    Grauer, Jared A.

    2016-01-01

    A real-time method for estimating time-varying aircraft frequency responses from input and output measurements was demonstrated. The Bat-4 subscale airplane was used with NASA Langley Research Center's AirSTAR unmanned aerial flight test facility to conduct flight tests and collect data for dynamic modeling. Orthogonal phase-optimized multisine inputs, summed with pilot stick and pedal inputs, were used to excite the responses. The aircraft was tested in its normal configuration and with emulated failures, which included a stuck left ruddervator and an increased command path latency. No prior knowledge of a dynamic model was used or available for the estimation. The longitudinal short period dynamics were investigated in this work. Time-varying frequency responses and stability margins were tracked well using a 20 second sliding window of data, as compared to a post-flight analysis using output error parameter estimation and a low-order equivalent system model. This method could be used in a real-time fault detection system, or for other applications of dynamic modeling such as real-time verification of stability margins during envelope expansion tests.

  1. The response-time distribution in a real-time database with optimistic concurrency control and constant execution times

    NARCIS (Netherlands)

    Sassen, S.A.E.; Wal, van der J.

    1997-01-01

    For a real-time shared-memory database with optimistic concurrency control, an approximation for the transaction response-time distribution is obtained. The model assumes that transactions arrive at the database according to a Poisson process, that every transaction uses an equal number of

  2. The response-time distribution in a real-time database with optimistic concurrency control and exponential execution times

    NARCIS (Netherlands)

    Sassen, S.A.E.; Wal, van der J.

    1997-01-01

    For a real-time shared-memory database with optimistic concurrency control, an approximation for the transaction response-time distribution is obtained. The model assumes that transactions arrive at the database according to a Poisson process, that every transaction takes an exponential execution

  3. Search for an optimum time response of spark counters

    International Nuclear Information System (INIS)

    Devismes, A.; Finck, Ch.; Kress, T.; Gobbi, A.; Eschke, J.; Herrmann, N.; Hildenbrand, K.D.; Koczon, P.; Petrovici, M.

    2002-01-01

    A spark counter of the type developed by Pestov has been tested with the aim of searching for an optimum time response function, changing voltage, content of noble and quencher gases, pressure and energy-loss. Replacing the usual argon by neon has brought an improvement of the resolution and a significant reduction of tails in the time response function. It has been proven that a counter as long as 90 cm can deliver, using neon gas mixture, a time resolution σ<60 ps with about 1% absolute tail and an efficiency of about 90%

  4. Effects of upper plenum injection on thermo-hydrodynamic behavior under refill and reflood phases

    International Nuclear Information System (INIS)

    Iwamura, Takamichi; Sobajima, Makoto; Abe, Yutaka; Adachi, Hiromichi; Ohnuki, Akira; Osakabe, Masahiro

    1984-12-01

    In order to investigate the thermo-hydrodynamic behavior in core under simultaneous ECC water injection into the upper plenum and the intact cold leg during the refill and reflood phases of a PWR-LOCA, Tests S1-SH3 and S1-SH4 were performed by using Slab Core Test Facility (SCTF) with the injection of saturated and 67K subcooled water into the upper plenum, respectively, under the same cold leg injection condition. The following major findings were obtained by examining these test results. (1) Although the core was cooled by the fall back water from the upper plenum into the core during the period of high injection rate into the upper plenum, the core was cooled mainly by the bottom flooding after the BOCREC (Bottom of core recovery). (2) The possible fall back flow rate estimated with a CCFL correlation rapidly decreased after the BOCREC because of the increase of steam generation rate in core. (3) Continuous fall back of subcooled water was not observed even under the condition with large upper plenum injection rate of subcooled water and with steam outflow through the lower plenum into the downcomer. The fall back was intermittently limited by the rapid increase of upward steam flow which was generated in the core due to the evaporation of the fall back water. (4) The rising of liquid level in the lower plenum was suppressed by the pressurization in core due to the evaporation of fall back water before the BOCREC and therefore the beginning of bottom reflood was delayed. Some selected data from Tests S1-SH3 and S1-SH4 are also included in this report. (author)

  5. Accurate and efficient calculation of response times for groundwater flow

    Science.gov (United States)

    Carr, Elliot J.; Simpson, Matthew J.

    2018-03-01

    We study measures of the amount of time required for transient flow in heterogeneous porous media to effectively reach steady state, also known as the response time. Here, we develop a new approach that extends the concept of mean action time. Previous applications of the theory of mean action time to estimate the response time use the first two central moments of the probability density function associated with the transition from the initial condition, at t = 0, to the steady state condition that arises in the long time limit, as t → ∞ . This previous approach leads to a computationally convenient estimation of the response time, but the accuracy can be poor. Here, we outline a powerful extension using the first k raw moments, showing how to produce an extremely accurate estimate by making use of asymptotic properties of the cumulative distribution function. Results are validated using an existing laboratory-scale data set describing flow in a homogeneous porous medium. In addition, we demonstrate how the results also apply to flow in heterogeneous porous media. Overall, the new method is: (i) extremely accurate; and (ii) computationally inexpensive. In fact, the computational cost of the new method is orders of magnitude less than the computational effort required to study the response time by solving the transient flow equation. Furthermore, the approach provides a rigorous mathematical connection with the heuristic argument that the response time for flow in a homogeneous porous medium is proportional to L2 / D , where L is a relevant length scale, and D is the aquifer diffusivity. Here, we extend such heuristic arguments by providing a clear mathematical definition of the proportionality constant.

  6. Congestion Service Facilities Location Problem with Promise of Response Time

    Directory of Open Access Journals (Sweden)

    Dandan Hu

    2013-01-01

    Full Text Available In many services, promise of specific response time is advertised as a commitment by the service providers for the customer satisfaction. Congestion on service facilities could delay the delivery of the services and hurts the overall satisfaction. In this paper, congestion service facilities location problem with promise of response time is studied, and a mixed integer nonlinear programming model is presented with budget constrained. The facilities are modeled as M/M/c queues. The decision variables of the model are the locations of the service facilities and the number of servers at each facility. The objective function is to maximize the demands served within specific response time promised by the service provider. To solve this problem, we propose an algorithm that combines greedy and genetic algorithms. In order to verify the proposed algorithm, a lot of computational experiments are tested. And the results demonstrate that response time has a significant impact on location decision.

  7. Elucidation of time-dependent systems biology cell response patterns with time course network enrichment

    DEFF Research Database (Denmark)

    Wiwie, Christian; Rauch, Alexander; Haakonsson, Anders

    2018-01-01

    , no methods exist to integrate time series data with networks, thus preventing the identification of time-dependent systems biology responses. We close this gap with Time Course Network Enrichment (TiCoNE). It combines a new kind of human-augmented clustering with a novel approach to network enrichment...

  8. The Importance of Responsibility in Times of Crisis

    OpenAIRE

    Jacob Dahl Rendtorff

    2014-01-01

    In this paper I would like to show the importance of the concept of responsibility as the foundation of ethics in times of crisis in particular in the fields of politics and economics in the modern civilisation marked by globalization and technological progres. I consider the concept of responsibility as the key notion in order to understand the ethical duty in a modern technological civilisation. We can indeed observe a moralization of the concept of responsibility going beyond a strict lega...

  9. Transformation Algorithm of Dielectric Response in Time-Frequency Domain

    Directory of Open Access Journals (Sweden)

    Ji Liu

    2014-01-01

    Full Text Available A transformation algorithm of dielectric response from time domain to frequency domain is presented. In order to shorten measuring time of low or ultralow frequency dielectric response characteristics, the transformation algorithm is used in this paper to transform the time domain relaxation current to frequency domain current for calculating the low frequency dielectric dissipation factor. In addition, it is shown from comparing the calculation results with actual test data that there is a coincidence for both results over a wide range of low frequencies. Meanwhile, the time domain test data of depolarization currents in dry and moist pressboards are converted into frequency domain results on the basis of the transformation. The frequency domain curves of complex capacitance and dielectric dissipation factor at the low frequency range are obtained. Test results of polarization and depolarization current (PDC in pressboards are also given at the different voltage and polarization time. It is demonstrated from the experimental results that polarization and depolarization current are affected significantly by moisture contents of the test pressboards, and the transformation algorithm is effective in ultralow frequency of 10−3 Hz. Data analysis and interpretation of the test results conclude that analysis of time-frequency domain dielectric response can be used for assessing insulation system in power transformer.

  10. How to successfully implement extended producer responsibility: considerations from an economic point of view.

    Science.gov (United States)

    Wiesmeth, Hans; Häckl, Dennis

    2011-09-01

    This paper investigates the concept of extended producer responsibility (EPR) from an economic point of view. Particular importance will be placed on the concept of 'economic feasibility' of an EPR policy, which should guide decision-making in this context. Moreover, the importance of the core EPR principle of 'integrating signals throughout the product chain' into the incentive structure will be demonstrated with experiences from Germany. These examples refer to sales packaging consumption, refillable drinks packages and waste electrical and electronic equipment collection. As a general conclusion, the interaction between economic principles and technological development needs to be observed carefully when designing incentive-compatible EPR policies.

  11. Detection of advance item knowledge using response times in computer adaptive testing

    NARCIS (Netherlands)

    Meijer, R.R.; Sotaridona, Leonardo

    2006-01-01

    We propose a new method for detecting item preknowledge in a CAT based on an estimate of “effective response time” for each item. Effective response time is defined as the time required for an individual examinee to answer an item correctly. An unusually short response time relative to the expected

  12. Response probability and response time: a straight line, the Tagging/Retagging interpretation of short term memory, an operational definition of meaningfulness and short term memory time decay and search time.

    Science.gov (United States)

    Tarnow, Eugen

    2008-12-01

    The functional relationship between correct response probability and response time is investigated in data sets from Rubin, Hinton and Wenzel, J Exp Psychol Learn Mem Cogn 25:1161-1176, 1999 and Anderson, J Exp Psychol [Hum Learn] 7:326-343, 1981. The two measures are linearly related through stimulus presentation lags from 0 to 594 s in the former experiment and for repeated learning of words in the latter. The Tagging/Retagging interpretation of short term memory is introduced to explain this linear relationship. At stimulus presentation the words are tagged. This tagging level drops slowly with time. When a probe word is reintroduced the tagging level has to increase for the word to be properly identified leading to a delay in response time. The tagging time is related to the meaningfulness of the words used-the more meaningful the word the longer the tagging time. After stimulus presentation the tagging level drops in a logarithmic fashion to 50% after 10 s and to 20% after 240 s. The incorrect recall and recognition times saturate in the Rubin et al. data set (they are not linear for large time lags), suggesting a limited time to search the short term memory structure: the search time for recall of unusual words is 1.7 s. For recognition of nonsense words the corresponding time is about 0.4 s, similar to the 0.243 s found in Cavanagh (1972).

  13. Effectiveness Analysis of a Part-Time Rapid Response System During Operation Versus Nonoperation.

    Science.gov (United States)

    Kim, Youlim; Lee, Dong Seon; Min, Hyunju; Choi, Yun Young; Lee, Eun Young; Song, Inae; Park, Jong Sun; Cho, Young-Jae; Jo, You Hwan; Yoon, Ho Il; Lee, Jae Ho; Lee, Choon-Taek; Do, Sang Hwan; Lee, Yeon Joo

    2017-06-01

    To evaluate the effect of a part-time rapid response system on the occurrence rate of cardiopulmonary arrest by comparing the times of rapid response system operation versus nonoperation. Retrospective cohort study. A 1,360-bed tertiary care hospital. Adult patients admitted to the general ward were screened. Data were collected over 36 months from rapid response system implementation (October 2012 to September 2015) and more than 45 months before rapid response system implementation (January 2009 to September 2012). None. The rapid response system operates from 7 AM to 10 PM on weekdays and from 7 AM to 12 PM on Saturdays. Primary outcomes were the difference of cardiopulmonary arrest incidence between pre-rapid response system and post-rapid response system periods and whether the rapid response system operating time affects the cardiopulmonary arrest incidence. The overall cardiopulmonary arrest incidence (per 1,000 admissions) was 1.43. Although the number of admissions per month and case-mix index were increased (3,555.18 vs 4,564.72, p times (0.82 vs 0.49/1,000 admissions; p = 0.001) but remained similar during rapid response system nonoperating times (0.77 vs 0.73/1,000 admissions; p = 0.729). The implementation of a part-time rapid response system reduced the cardiopulmonary arrest incidence based on the reduction of cardiopulmonary arrest during rapid response system operating times. Further analysis of the cost effectiveness of part-time rapid response system is needed.

  14. Frequency-dependent effects of background noise on subcortical response timing.

    Science.gov (United States)

    Tierney, A; Parbery-Clark, A; Skoe, E; Kraus, N

    2011-12-01

    The addition of background noise to an auditory signal delays brainstem response timing. This effect has been extensively documented using manual peak selection. Peak picking, however, is impractical for large-scale studies of spectrotemporally complex stimuli, and leaves open the question of whether noise-induced delays are frequency-dependent or occur across the frequency spectrum. Here we use an automated, objective method to examine phase shifts between auditory brainstem responses to a speech sound (/da/) presented with and without background noise. We predicted that shifts in neural response timing would also be reflected in frequency-specific phase shifts. Our results indicate that the addition of background noise causes phase shifts across the subcortical response spectrum (70-1000 Hz). However, this noise-induced delay is not uniform such that some frequency bands show greater shifts than others: low-frequency phase shifts (300-500 Hz) are largest during the response to the consonant-vowel formant transition (/d/), while high-frequency shifts (720-1000 Hz) predominate during the response to the steady-state vowel (/a/). Most importantly, phase shifts occurring in specific frequency bands correlate strongly with shifts in the latencies of the predominant peaks in the auditory brainstem response, while phase shifts in other frequency bands do not. This finding confirms the validity of phase shift detection as an objective measure of timing differences and reveals that this method detects noise-induced shifts in timing that may not be captured by traditional peak latency measurements. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Can Previewing Sport-Specific Video Influence Reactive-Agility Response Time?

    Science.gov (United States)

    Holding, Ryan; Meir, Rudi; Zhou, Shi

    2017-02-01

    The purpose of this study was to examine whether a video-based warm-up could provide an acute performance benefit to response time for athletes in a sport-specific agility task. In addition, 2 learning strategies, explicit and implicit, were compared for their effectiveness in facilitating an improvement in sport-specific agility. Thirty representative male junior rugby union players (age 14-16 y, mean age 14.6 ± 1.09 y) were placed in 3 experimental groups (explicit, implicit, and control) and completed 2 intervention sessions. Testing sessions included preintervention testing, completion of the video-based warm-up intervention, and postintervention testing. A 3D motion-analysis system was used to assess response time in the testing battery. The athletes' response times on the pre- to postintervention tests were compared to determine the effectiveness of the video-based warm-up. A 2-way general linear model with repeated-measures analysis indicated that both the explicit (P = .030, d = 0.28) and implicit (P = .049, d = 0.33) groups significantly improved their response time by the intervention compared with the control group (P = .367, d = 0.08). The mean postintervention response time for the explicit group improved by 19.1% (from 0.246 s pre to 0.199 s post), and the implicit group improved by 15.7% (from 0.268 s to 0.226 s). Findings suggest that a video-based warm-up may provide an acute benefit to sport-specific agility performance for junior athletes.

  16. Excited-state absorption in tetrapyridyl porphyrins: comparing real-time and quadratic-response time-dependent density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Bowman, David N. [Department of Chemistry; Supercomputing Institute and Chemical Theory Center; University of Minnesota; Minneapolis; USA; Asher, Jason C. [Department of Chemistry; Supercomputing Institute and Chemical Theory Center; University of Minnesota; Minneapolis; USA; Fischer, Sean A. [William R. Wiley Environmental Molecular Sciences Laboratory; Pacific Northwest National Laboratory; P.O. Box 999; Richland; USA; Cramer, Christopher J. [Department of Chemistry; Supercomputing Institute and Chemical Theory Center; University of Minnesota; Minneapolis; USA; Govind, Niranjan [William R. Wiley Environmental Molecular Sciences Laboratory; Pacific Northwest National Laboratory; P.O. Box 999; Richland; USA

    2017-01-01

    Threemeso-substituted tetrapyridyl porphyrins (free base, Ni(ii), and Cu(ii)) were investigated for their optical limiting (OL) capabilities using real-time (RT-), linear-response (LR-), and quadratic-response (QR-) time-dependent density functional theory (TDDFT) methods.

  17. A comparison of two procedures for verbal response time fractionation

    Directory of Open Access Journals (Sweden)

    Lotje evan der Linden

    2014-10-01

    Full Text Available To describe the mental architecture between stimulus and response, cognitive models often divide the stimulus-response (SR interval into stages or modules. Predictions derived from such models are typically tested by focusing on the moment of response emission, through the analysis of response time (RT distributions. To go beyond the single response event, we recently proposed a method to fractionate verbal RTs into two physiologically defined intervals that are assumed to reflect different processing stages. The analysis of the durations of these intervals can be used to study the interaction between cognitive and motor processing during speech production. Our method is inspired by studies on decision making that used manual responses, in which RTs were fractionated into a premotor time (PMT, assumed to reflect cognitive processing, and a motor time (MT, assumed to reflect motor processing. In these studies, surface EMG activity was recorded from participants' response fingers. EMG onsets, reflecting the initiation of a motor response, were used as the point of fractionation. We adapted this method to speech-production research by measuring verbal responses in combination with EMG activity from facial muscles involved in articulation. However, in contrast to button-press tasks, the complex task of producing speech often resulted in multiple EMG bursts within the SR interval. This observation forced us to decide how to operationalize the point of fractionation: as the first EMG burst after stimulus onset (the stimulus-locked approach, or as the EMG burst that is coupled to the vocal response (the response-locked approach. The point of fractionation has direct consequences on how much of the overall task effect is captured by either interval. Therefore, the purpose of the current paper was to compare both onset-detection procedures in order to make an informed decision about which of the two is preferable. We concluded in favour or the response

  18. Emergency response guide-B ECCS guideline evaluation analyses for N reactor

    International Nuclear Information System (INIS)

    Chapman, J.C.; Callow, R.A.

    1989-07-01

    INEL conducted two ECCS analyses for Westinghouse Hanford. Both analyses will assist in the evaluation of proposed changes to the N Reactor Emergency Response Guide-B (ERG-B) Emergency Core System (ECCS) guideline. The analyses were a sensitivity study for reduced-ECCS flow rates and a mechanistically determined confinement steam source for a delayed-ECCS LOCA sequence. The reduced-ECCS sensitivity study established the maximum allowable reduction in ECCS flow as a function of time after core refill for a large break loss-of-coolant accident (LOCA) sequence in the N Reactor. The maximum allowable ECCS flow reduction is defined as the maximum flow reduction for which ECCS continues to provide adequate core cooling. The delayed-ECCS analysis established the liquid and steam break flows and enthalpies during the reflood of a hot core following a delayed ECCS injection LOCA sequence. A simulation of a large, hot leg manifold break with a seven-minute ECCS injection delay was used as a representative LOCA sequence. Both analyses were perform using the RELAP5/MOD2.5 transient computer code. 13 refs., 17 figs., 3 tabs

  19. Which adherence measure - self-report, clinician recorded or pharmacy refill - is best able to predict detectable viral load in a public ART programme without routine plasma viral load monitoring?

    Science.gov (United States)

    Mekuria, Legese A; Prins, Jan M; Yalew, Alemayehu W; Sprangers, Mirjam A G; Nieuwkerk, Pythia T

    2016-07-01

    Combination antiretroviral therapy (cART) suppresses viral replication to an undetectable level if a sufficiently high level of adherence is achieved. We investigated which adherence measurement best distinguishes between patients with and without detectable viral load in a public ART programme without routine plasma viral load monitoring. We randomly selected 870 patients who started cART between May 2009 and April 2012 in 10 healthcare facilities in Addis Ababa, Ethiopia. Six hundred and sixty-four (76.3%) patients who were retained in HIV care and were receiving cART for at least 6 months were included and 642 had their plasma HIV-1 RNA concentration measured. Patients' adherence to cART was assessed according to self-report, clinician recorded and pharmacy refill measures. Multivariate logistic regression model was fitted to identify the predictors of detectable viremia. Model accuracy was evaluated by computing the area under the receiver operating characteristic (ROC) curve. A total of 9.2% and 5.5% of the 642 patients had a detectable viral load of ≥40 and ≥400 RNA copies/ml, respectively. In the multivariate analyses, younger age, lower CD4 cell count at cART initiation, being illiterate and widowed, and each of the adherence measures were significantly and independently predictive of having ≥400 RNA copies/ml. The ROC curve showed that these variables altogether had a likelihood of more than 80% to distinguish patients with a plasma viral load of ≥400 RNA copies/ml from those without. Adherence to cART was remarkably high. Self-report, clinician recorded and pharmacy refill non-adherence were all significantly predictive of detectable viremia. The choice for one of these methods to detect non-adherence and predict a detectable viral load can therefore be based on what is most practical in a particular setting. © 2016 John Wiley & Sons Ltd.

  20. Reclaiming Spare Capacity and Improving Aperiodic Response Times in Real-Time Environments

    Directory of Open Access Journals (Sweden)

    Liu Xue

    2011-01-01

    Full Text Available Abstract Scheduling recurring task sets that allow some instances of the tasks to be skipped produces holes in the schedule which are nonuniformly distributed. Similarly, when the recurring tasks are not strictly periodic but are sporadic, there is extra processor bandwidth arising because of irregular job arrivals. The additional computation capacity that results from skips or sporadic tasks can be reclaimed to service aperiodic task requests efficiently and quickly. We present techniques for improving the response times of aperiodic tasks by identifying nonuniformly distributed spare capacity—because of skips or sporadic tasks—in the schedule and adding such extra capacity to the capacity queue of a BASH server. These gaps can account for a significant portion of aperiodic capacity, and their reclamation results in considerable improvement to aperiodic response times. We present two schemes: NCLB-CBS, which performs well in periodic real-time environments with firm tasks, and NCLB-CUS, which can be deployed when the basic task set to schedule is sporadic. Evaluation via simulations and implementation suggests that performance improvements for aperiodic tasks can be obtained with limited additional overhead.

  1. Time response measurements of LASL diagnostic detectors

    International Nuclear Information System (INIS)

    Hocker, L.P.

    1970-07-01

    The measurement and data analysis techniques developed under the Los Alamos Scientific Laboratory's detector improvement program were used to characterize the time and frequency response of selected LASL Compton, fluor-photodiode (NPD), and fluor-photomultiplier (NPM) diagnostic detectors. Data acquisition procedures and analysis methods presently in use are summarized, and detector time and frequency data obtained using the EG and G/AEC electron linear accelerator fast pulse (approximately 50 psec FWHM) as the incident radiation driving function are presented. (U.S.)

  2. Comparison study of time history and response spectrum responses for multiply supported piping systems

    International Nuclear Information System (INIS)

    Wang, Y.K.; Subudhi, M.; Bezler, P.

    1983-01-01

    In the past decade, several investigators have studied the problem of independent support excitation of a multiply supported piping system to identify the real need for such an analysis. This approach offers an increase in accuracy at a small increase in computational costs. To assess the method, studies based on the response spectrum approach using independent support motions for each group of commonly connected supports were performed. The results obtained from this approach were compared with the conventional envelope spectrum and time history solutions. The present study includes a mathematical formulation of the independent support motion analysis method suitable for implementation into an existing all purpose piping code PSAFE2 and a comparison of the solutions for some typical piping system using both Time History and Response Spectrum Methods. The results obtained from the Response Spectrum Methods represent the upper bound solution at most points in the piping system. Similarly, the Seismic Anchor Movement analysis based on the SRP method over predicts the responses near the support points and under predicts at points away from the supports

  3. 10 CFR 603.1000 - Contracting officer's responsibilities at time of award.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Contracting officer's responsibilities at time of award. 603.1000 Section 603.1000 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS TECHNOLOGY INVESTMENT AGREEMENTS Executing the Award § 603.1000 Contracting officer's responsibilities at time of award...

  4. Evaluating perceptual integration: uniting response-time- and accuracy-based methodologies.

    Science.gov (United States)

    Eidels, Ami; Townsend, James T; Hughes, Howard C; Perry, Lacey A

    2015-02-01

    This investigation brings together a response-time system identification methodology (e.g., Townsend & Wenger Psychonomic Bulletin & Review 11, 391-418, 2004a) and an accuracy methodology, intended to assess models of integration across stimulus dimensions (features, modalities, etc.) that were proposed by Shaw and colleagues (e.g., Mulligan & Shaw Perception & Psychophysics 28, 471-478, 1980). The goal was to theoretically examine these separate strategies and to apply them conjointly to the same set of participants. The empirical phases were carried out within an extension of an established experimental design called the double factorial paradigm (e.g., Townsend & Nozawa Journal of Mathematical Psychology 39, 321-359, 1995). That paradigm, based on response times, permits assessments of architecture (parallel vs. serial processing), stopping rule (exhaustive vs. minimum time), and workload capacity, all within the same blocks of trials. The paradigm introduced by Shaw and colleagues uses a statistic formally analogous to that of the double factorial paradigm, but based on accuracy rather than response times. We demonstrate that the accuracy measure cannot discriminate between parallel and serial processing. Nonetheless, the class of models supported by the accuracy data possesses a suitable interpretation within the same set of models supported by the response-time data. The supported model, consistent across individuals, is parallel and has limited capacity, with the participants employing the appropriate stopping rule for the experimental setting.

  5. Ultimate response time of high electron mobility transistors

    International Nuclear Information System (INIS)

    Rudin, Sergey; Rupper, Greg; Shur, Michael

    2015-01-01

    We present theoretical studies of the response time of the two-dimensional gated electron gas to femtosecond pulses. Our hydrodynamic simulations show that the device response to a short pulse or a step-function signal is either smooth or oscillating time-decay at low and high mobility, μ, values, respectively. At small gate voltage swings, U 0  = U g  − U th , where U g is the gate voltage and U th is the threshold voltage, such that μU 0 /L < v s , where L is the channel length and v s is the effective electron saturation velocity, the decay time in the low mobility samples is on the order of L 2 /(μU 0 ), in agreement with the analytical drift model. However, the decay is preceded by a delay time on the order of L/s, where s is the plasma wave velocity. This delay is the ballistic transport signature in collision-dominated devices, which becomes important during very short time periods. In the high mobility devices, the period of the decaying oscillations is on the order of the plasma wave velocity transit time. Our analysis shows that short channel field effect transistors operating in the plasmonic regime can meet the requirements for applications as terahertz detectors, mixers, delay lines, and phase shifters in ultra high-speed wireless communication circuits

  6. Impact of e-cigarette refill liquid with or without nicotine on liver function in adult rats.

    Science.gov (United States)

    El Golli, Narges; Jrad-Lamine, Aicha; Neffati, Hajira; Rahali, Dalila; Dallagi, Yosra; Dkhili, Houssem; Ba, Nathalie; El May, Michele V; El Fazaa, Saloua

    2016-07-01

    This study was conducted to evaluate the effects of e-cigarette refill liquid administration alone or with nicotine on the antioxidant defense status, functional and histopathological changes in adult rat liver tissue. For this purpose, 32 rats were treated for 28 days as follows: control group was injected intra-peritoneally with physiological saline; e-cigarette 0% treated group received an intra-peritoneal injection of e-liquid without nicotine diluted in physiological saline, e-cigarette-treated group received an intra-peritoneal injection of e-liquid containing 0.5 mg of nicotine/kg of body weight/day diluted in physiological saline and nicotine-treated group received an intra-peritoneal injection of 0.5 mg of nicotine/kg of body weight/day diluted in physiological saline. In e-liquid without nicotine-exposed group, activities of the liver biomarkers aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase and lactate dehydrogenase increase. Interestingly, oxidative stress indicators showed decreased total protein content, associated with a reduction in the antioxidant enzymes activities superoxide dismutase, catalase and glutathione-S-transferase, and an elevation in malondialdehyde content, highlighting the promotion of lipid peroxidation and oxidative stress. Histological studies identified inflammatory cells infiltration and cell death. Thus, e-liquid seems to promote oxidative tissue injuries, which in turn lead to the observed histopathological finding. In comparison, nicotine alone induced less oxidative stress and less histopathological disorders, whereas e-liquid with nicotine gave rise to more histopathological injuries. Thereby, e-liquid, per se, is able to induce hepatotoxicity and supplementation with nicotine worsens this state.

  7. More is not Always Better: The Relation between Item Response and Item Response Time in Raven’s Matrices

    Directory of Open Access Journals (Sweden)

    Frank Goldhammer

    2015-03-01

    Full Text Available The role of response time in completing an item can have very different interpretations. Responding more slowly could be positively related to success as the item is answered more carefully. However, the association may be negative if working faster indicates higher ability. The objective of this study was to clarify the validity of each assumption for reasoning items considering the mode of processing. A total of 230 persons completed a computerized version of Raven’s Advanced Progressive Matrices test. Results revealed that response time overall had a negative effect. However, this effect was moderated by items and persons. For easy items and able persons the effect was strongly negative, for difficult items and less able persons it was less negative or even positive. The number of rules involved in a matrix problem proved to explain item difficulty significantly. Most importantly, a positive interaction effect between the number of rules and item response time indicated that the response time effect became less negative with an increasing number of rules. Moreover, exploratory analyses suggested that the error type influenced the response time effect.

  8. Time-Lapse and Slow-Motion Tracking of Temperature Changes: Response Time of a Thermometer

    Science.gov (United States)

    Moggio, L.; Onorato, P.; Gratton, L. M.; Oss, S.

    2017-01-01

    We propose the use of a smartphone based time-lapse and slow-motion video techniques together with tracking analysis as valuable tools for investigating thermal processes such as the response time of a thermometer. The two simple experimental activities presented here, suitable also for high school and undergraduate students, allow one to measure…

  9. Fast-Response-Time Shape-Memory-Effect Foam Actuators

    Science.gov (United States)

    Jardine, Peter

    2010-01-01

    Bulk shape memory alloys, such as Nitinol or CuAlZn, display strong recovery forces undergoing a phase transformation after being strained in their martensitic state. These recovery forces are used for actuation. As the phase transformation is thermally driven, the response time of the actuation can be slow, as the heat must be passively inserted or removed from the alloy. Shape memory alloy TiNi torque tubes have been investigated for at least 20 years and have demonstrated high actuation forces [3,000 in.-lb (approximately equal to 340 N-m) torques] and are very lightweight. However, they are not easy to attach to existing structures. Adhesives will fail in shear at low-torque loads and the TiNi is not weldable, so that mechanical crimp fits have been generally used. These are not reliable, especially in vibratory environments. The TiNi is also slow to heat up, as it can only be heated indirectly using heater and cooling must be done passively. This has restricted their use to on-off actuators where cycle times of approximately one minute is acceptable. Self-propagating high-temperature synthesis (SHS) has been used in the past to make porous TiNi metal foams. Shape Change Technologies has been able to train SHS derived TiNi to exhibit the shape memory effect. As it is an open-celled material, fast response times were observed when the material was heated using hot and cold fluids. A methodology was developed to make the open-celled porous TiNi foams as a tube with integrated hexagonal ends, which then becomes a torsional actuator with fast response times. Under processing developed independently, researchers were able to verify torques of 84 in.-lb (approximately equal to 9.5 Nm) using an actuator weighing 1.3 oz (approximately equal to 37 g) with very fast (less than 1/16th of a second) initial response times when hot and cold fluids were used to facilitate heat transfer. Integrated structural connections were added as part of the net shape process, eliminating

  10. Responses to interracial interactions over time.

    Science.gov (United States)

    Plant, E Ashby

    2004-11-01

    The current work tested and expanded on Plant and Devine's (2003) model of the antecedents and implications of interracial anxiety by examining people's experiences with interracial interactions at two time points. Study 1 explored non-Black people's responses to interactions with Black people and Study 2 explored Black people's responses to interactions with White people. Non-Black participants' expectancies about coming across as biased in interracial interactions and Black participants' expectancies about White people's bias predicted their interracial anxiety and whether they had positive interactions with outgroup members during the 2 weeks between assessments. Across both studies, interracial anxiety predicted the desire to avoid interactions with outgroup members. In addition, participants who were personally motivated to respond without prejudice reported more positive expectancies. The findings are discussed in terms of the implications for understanding the course and quality of interracial interactions.

  11. Simulations of hybrid system varying solar radiation and microturbine response time

    Directory of Open Access Journals (Sweden)

    Yolanda Fernández Ribaya

    2015-07-01

    Full Text Available Hybrid power systems, such as combinations of renewable power sources with intermittent power production and non-renewable power sources, theoretically increase the reliability and thus integration of renewable sources in the electrical system. However, a recent increase in the number of hybrid installations has sparked interest in the effects of their connection to the grid, especially in remote areas. This paper analyses a photovoltaic-gas microturbine hybrid system dimensioned to be installed in La Paz (Mexico.The research presented in this paper studies and quantifies the effects on the total electric power produced, varying both the solar radiation and the gas microturbine response time. The gas microturbine and the photovoltaic panels are modelled using Matlab/Simulink software, obtaining a platform where different tests to simulate real conditions have been executed. They consist of diverse ramps of irradiance that replicate solar radiation variations, and different microturbine response times reproduced by the time constants of a first order transfer function that models the microturbine dynamic response. The results obtained show that when radiation varies quickly it does not produce significant differences in the power guarantee or the microturbine gas consumption, to any microturbine response time. However, these two parameters are highly variable with smooth radiance variations. The maximum total power variation decreases greatly as the radiation variation gets lower. In addition, by decreasing the microturbine response time, it is possible to appreciably increase the power guarantee although the maximum power variation and gas consumption increase. Only in cases of low radiation variation is there no appreciable difference in the maximum power variation obtained by the different turbine response times.

  12. Simulations of hybrid system varying solar radiation and microturbine response time

    Energy Technology Data Exchange (ETDEWEB)

    Fernández Ribaya, Yolanda, E-mail: fernandezryolanda@uniovi.es; Álvarez, Eduardo; Paredes Sánchez, José Pablo; Xiberta Bernat, Jorge [Department of Energy E.I.M.E.M., University of Oviedo. 13 Independencia Street 2" n" d floor, 36004, Oviedo (Spain)

    2015-07-15

    Hybrid power systems, such as combinations of renewable power sources with intermittent power production and non-renewable power sources, theoretically increase the reliability and thus integration of renewable sources in the electrical system. However, a recent increase in the number of hybrid installations has sparked interest in the effects of their connection to the grid, especially in remote areas. This paper analyses a photovoltaic-gas microturbine hybrid system dimensioned to be installed in La Paz (Mexico).The research presented in this paper studies and quantifies the effects on the total electric power produced, varying both the solar radiation and the gas microturbine response time. The gas microturbine and the photovoltaic panels are modelled using Matlab/Simulink software, obtaining a platform where different tests to simulate real conditions have been executed. They consist of diverse ramps of irradiance that replicate solar radiation variations, and different microturbine response times reproduced by the time constants of a first order transfer function that models the microturbine dynamic response. The results obtained show that when radiation varies quickly it does not produce significant differences in the power guarantee or the microturbine gas consumption, to any microturbine response time. However, these two parameters are highly variable with smooth radiance variations. The maximum total power variation decreases greatly as the radiation variation gets lower. In addition, by decreasing the microturbine response time, it is possible to appreciably increase the power guarantee although the maximum power variation and gas consumption increase. Only in cases of low radiation variation is there no appreciable difference in the maximum power variation obtained by the different turbine response times.

  13. In situ response time measurements of RTD temperature sensors

    International Nuclear Information System (INIS)

    Goncalves, I.M.P.

    1985-01-01

    The loop-current-step-response test provides a mean for determining the time constant of resistence thermometers. The test consist in heating the sensor a few degrees above ambient temperature by causing a step pertubation in the electric current that flows through the sensor leads. The developed mathematical transformation permits to use data collected during the internal heating transient to predict the sensor response to perturbations in fluid temperature. Experimental data obtained show that the time constant determined by method is within 15 percent of true value. The loop-current-step-response test is a remote in situ test, which can be performed with the sensor installed in the process. Consequently it takes account the local heat transfer conditions, and appropriated for nuclear power plants, where sensors are installed in points of difficult access. (author) [pt

  14. Corrective response times in a coordinated eye-head-arm countermanding task.

    Science.gov (United States)

    Tao, Gordon; Khan, Aarlenne Z; Blohm, Gunnar

    2018-06-01

    Inhibition of motor responses has been described as a race between two competing decision processes of motor initiation and inhibition, which manifest as the reaction time (RT) and the stop signal reaction time (SSRT); in the case where motor initiation wins out over inhibition, an erroneous movement occurs that usually needs to be corrected, leading to corrective response times (CRTs). Here we used a combined eye-head-arm movement countermanding task to investigate the mechanisms governing multiple effector coordination and the timing of corrective responses. We found a high degree of correlation between effector response times for RT, SSRT, and CRT, suggesting that decision processes are strongly dependent across effectors. To gain further insight into the mechanisms underlying CRTs, we tested multiple models to describe the distribution of RTs, SSRTs, and CRTs. The best-ranked model (according to 3 information criteria) extends the LATER race model governing RTs and SSRTs, whereby a second motor initiation process triggers the corrective response (CRT) only after the inhibition process completes in an expedited fashion. Our model suggests that the neural processing underpinning a failed decision has a residual effect on subsequent actions. NEW & NOTEWORTHY Failure to inhibit erroneous movements typically results in corrective movements. For coordinated eye-head-hand movements we show that corrective movements are only initiated after the erroneous movement cancellation signal has reached a decision threshold in an accelerated fashion.

  15. Sequential determination of nickel and cadmium in tobacco, molasses and refill solutions for e-cigarettes samples by molecular fluorescence.

    Science.gov (United States)

    Talio, María Carolina; Alesso, Magdalena; Acosta, Mariano; Wills, Verónica S; Fernández, Liliana P

    2017-11-01

    In this work, a new procedure was developed for separation and preconcentration of nickel(II) and cadmium(II) in several and varied tobacco samples. Tobacco samples were selected considering the main products consumed by segments of the population, in particular the age (youth) and lifestyle of the consumer. To guarantee representative samples, a randomized strategy of sampling was used. In the first step, a chemofiltration on nylon membrane is carried out employing eosin (Eo) and carbon nanotubes dispersed in sodium dodecylsulfate (SDS) solution (phosphate buffer pH 7). In this condition, Ni(II) was selectively retained on the solid support. After that, the filtrate liquid with Cd(II) was re-conditioned with acetic acid /acetate buffer solution (pH 5) and followed by detection. A spectrofluorimetric determination of both metals was carried out, on the solid support and the filtered aqueous solution, for Ni(II) and Cd(II), respectively. The solid surface fluorescence (SSF) determination was performed at λ em = 545nm (λ ex = 515nm) for Ni(II)-Eo complex and the fluorescence of Cd(II)-Eo was quantified in aqueous solution using λ em = 565nm (λ ex = 540nm). The calibration graphs resulted linear in a range of 0.058-29.35μgL -1 for Ni(II) and 0.124-56.20μgL -1 for Cd(II), with detection limits of 0.019 and 0.041μgL -1 (S/N = 3). The developed methodology shows good sensitivity and adequate selectivity, and it was successfully applied to the determination of trace amounts of nickel and cadmium present in tobacco samples (refill solutions for e-cigarettes, snuff used in narguille (molasses) and traditional tobacco) with satisfactory results. The new methodology was validated by ICP-MS with adequate agreement. The proposed methodology represents a novel fluorescence application to Ni(II) and Cd(II) quantification with sensitivity and accuracy similar to atomic spectroscopies, introducing for the first time the quenching effect on SSF. Copyright © 2017 Elsevier B

  16. Reduced computational cost in the calculation of worst case response time for real time systems

    OpenAIRE

    Urriza, José M.; Schorb, Lucas; Orozco, Javier D.; Cayssials, Ricardo

    2009-01-01

    Modern Real Time Operating Systems require reducing computational costs even though the microprocessors become more powerful each day. It is usual that Real Time Operating Systems for embedded systems have advance features to administrate the resources of the applications that they support. In order to guarantee either the schedulability of the system or the schedulability of a new task in a dynamic Real Time System, it is necessary to know the Worst Case Response Time of the Real Time tasks ...

  17. Impact of insufficient energy content in the design time history on the structure response

    International Nuclear Information System (INIS)

    Ma, D.C.; Gvildys, J.; Chang, Y.W.; Seidensticker, R.W.

    1989-01-01

    In the design of nuclear power plants, it is often desirable to use the time history method in the soil-structure interaction analysis to determine the plant floor response to seismic loads. Because many design criteria are specified in terms of design response spectra, the artificial time history needs to be generated under the requirement that the response spectra of the artificial history should envelop the given design response spectra. However, recent studies indicate that the artificial time history used in the plant design may have insufficient energy in the frequency range of interest, even though the response spectra of the design time history closely envelop the design response spectra. This paper presents an investigation of the effects of the insufficient energy content in the design time history on the response of the soil-structure system. Numerical studies were carried out. Both the real earthquake records and the artificial time histories were used as the input motions in a simple lumped-mass soil-structure interaction model. The results obtained from this study provide a better understanding of the effects of the insufficient energy content in the design time history on the structural response

  18. Relationship Between Time Consumption and Quality of Responses to Drug-related Queries

    DEFF Research Database (Denmark)

    Amundstuen Reppe, Linda; Lydersen, Stian; Schjøtt, Jan

    2016-01-01

    in score, –0.05 per hour of work; 95% CI, –0.08 to –0.01; P = 0.005). No such associations were found for the internal experts’ assessment. Implications To our knowledge, this is the first study of the association between time consumption and quality of responses to drug-related queries in DICs......Purpose The aims of this study were to assess the quality of responses produced by drug information centers (DICs) in Scandinavia, and to study the association between time consumption processing queries and the quality of the responses. Methods We posed six identical drug-related queries to seven...... DICs in Scandinavia, and the time consumption required for processing them was estimated. Clinical pharmacologists (internal experts) and general practitioners (external experts) reviewed responses individually. We used mixed model linear regression analyses to study the associations between time...

  19. Improved AMD counters quicky type to achieve a level of 0.2 log derivative mSv output in counts refills; Mejora de la AMD en contadores tipo quicky para conseguir un nivel derivado de registro de 0,2 mSV en contajes de salida en recargas

    Energy Technology Data Exchange (ETDEWEB)

    Bravp Perez-Tinao, B.; Marchena Gonzalez, P.; Sollet Danudo, E.

    2011-07-01

    To ensure that no worker receives contract exposed by internal exposure dose computed not exceed 1 mSv / year, the Nuclear Security Council requested the Spanish nuclear power plants and Tecnatom that in 2010 would ensure a level derived from registration in internal dosimetry counts refills output equal to or less than 0.2 mSv, which represented a reduction of AMD computers.

  20. Generation of artificial time-histories, rich in all frequencies, from given response spectra

    International Nuclear Information System (INIS)

    Levy, S.; Wilkinson, J.P.D.

    1976-01-01

    In the design of nuclear power plants, it has been found desirable in certain instances to use the time-history method of dynamic analysis to determine the plant response to seismic input. In the implementation of this method, it is necessary to determine an adequate representation of the excitation as a function of time. Because many design criteria are specified in terms of design response spectra one is faced with the problem of generating a time-history whose own response spectrum approximates as far as possible to the originally specified design response spectrum. One objective of this paper is to present a method of synthesizing such time-histories from a given design response spectrum. The design response spectra may be descriptive of floor responses at a particular location in a plant, or they may be descriptive of seismic ground motions at a plant site. The method described in this paper allows the generation of time histories that are rich in all frequencies in the spectrum. This richness is achieved by choosing a large number of closely-spaced frequency points such that the half-power points of adjacent frequencies overlap. Examples are given concerning seismic design response spectra, and a number of points are discussed concerning the effect of frequency spacing on convergence. (Auth.)

  1. Using random response input in Ibrahim Time Domain

    DEFF Research Database (Denmark)

    Olsen, Peter; Brincker, R.

    2013-01-01

    In this paper the time domain technique Ibrahim Time Domain (ITD) is used to analyze random time data. ITD is known to be a technique for identification of output only systems. The traditional formulation of ITD is claimed to be limited, when identifying closely spaced modes, because....... In this article it is showed that when using the modified ITD random time data can be analyzed. The application of the technique is displayed by a case study, with simulations and experimental data....... of the technique being Single Input Multiple Output (SIMO). It has earlier been showed that when modifying ITD with Toeplitz matrix averaging. Identification of time data with closely spaced modes is improved. In the traditional formulation of ITD the time data has to be free decays or impulse response functions...

  2. Impact of insufficient energy content in the design time history on the structure response

    International Nuclear Information System (INIS)

    Ma, D.C.; Gvildys, J.; Chang, Y.W.; Seidensticker, R.W.

    1989-01-01

    In the design of nuclear power plants, it is often desirable to use the time history method in the soil-structure interaction analysis to determine the plant floor response to seismic loads. Because many design criteria are specified in terms of design response spectra, the artificial time history needs to be generated under the requirement that the response spectra of the artificial history should envelop the given design response spectra. However, recent studies indicate that the artificial time history used in the plant design may have insufficient energy in the frequency range of interest, even though the response spectra of the design time history closely envelop the design response spectra. Therefore, the proposed changes in the NRC Standard Review Plan requires that when a single time history is used in the seismic design, it must satisfy requirements for both response spectra enveloping and matching a power spectra density (PSD) function in the frequency range of interest. The use of multiple artificial time histories (at least five time histories) in the plant design is also suggested in the new Standard Review Plan. This paper presents an investigation of the effects of the insufficient energy content in the design time history on the response of the soil-structure system. Numerical studies were carried out. Both the real earthquake records and the artificial time histories were used as the input motions in a simple lumped-mass soil-structure interaction model. The results obtained from this study provide a better understanding of the effects of the insufficient energy content in the design time history on the structural response. 5 refs., 10 figs., 1 tab

  3. A study on HCI design strategy using emergent features and response time

    International Nuclear Information System (INIS)

    Lee, Sung Jin; Chang, Soon Heung; Park, Jin Gyun

    2001-01-01

    Existing design process of user interface has some weak point that there is no feedback information and no quantitative information between each sub process. If they're such information in design process, the design time cycle will be decreased and the contentment of HCI in the aspect of user will be more easily archived. In this study, new design process with feedback information and quantitative information was proposed using emergent features and user response time. The proposed methodology was put together with three main parts. First part is to calculate distinctiveness of a user interface or expanded user interface with consideration of emergent features. Second part is to expand a prototype user interface with design option for purpose of design requirement using directed structure graph (or nodal graph) theory. Last part is to convert non-realized value, distinctiveness, into realized value, response time, by response time database or response time correlation in the form of Hick-Hyman law equation. From the present validations, the usefulness of the proposed methodology was obtained by simple validation testing. It was found that emergent features should be improved for high reflection of real user interface. For the reliability of response time database, lots of end-user experiment is necessary. Expansion algorithm and representation technique of qualitative information should be somewhat improved for more efficient design process

  4. Photoconductivity response time in amorphous semiconductors

    Science.gov (United States)

    Adriaenssens, G. J.; Baranovskii, S. D.; Fuhs, W.; Jansen, J.; Öktü, Ö.

    1995-04-01

    The photoconductivity response time of amorphous semiconductors is examined theoretically on the basis of standard definitions for free- and trapped-carrier lifetimes, and experimentally for a series of a-Si1-xCx:H alloys with xgeneration rate and temperature. As no satisfactory agreement between models and experiments emerges, a simple theory is developed that can account for the experimental observations on the basis of the usual multiple-trappping ideas, provided a small probability of direct free-carrier recombination is included. The theory leads to a stretched-exponential photocurrent decay.

  5. Justification of response time testing requirements for pressure and differential pressure sensors

    International Nuclear Information System (INIS)

    Weiss, J.M.; Mayo, C.; Swisher, V.

    1991-01-01

    This paper reports on response time testing (RTT) requirements that were imposed on pressure, differential pressure sensors as a conservative approach to insure that assumptions in the plant safety analyses were met. The purpose of this project has been to identify the need for response time testing using the bases identified in IEEE Standard 338. A combination of plant data analyses, failure modes, and effects analyses (FMEAs) was performed. Eighteen currently qualified sensor models were utilized. The results of these analyses indicate that there are only two failure modes that affect response time, not sensor output concurrently. For these failure modes, appropriate plant actions and testing techniques were identified. Safety system RTT requirements were established by IEEE Standard 338-1975. Criteria for the Periodic Testing of Class IE Power, Protection Systems, presuming the need existed for this testing. This standard established guidelines for periodic testing to verify that loop response times of installed nuclear safety-related equipment were within the limits presumed by the design basis plant transient, accident analyses. The requirements covered all passive, active components in an instrument loop, including sensors. Individual components could be tested either in groups or separately to determine the overall loop response time

  6. Generation of synthetic time histories compatible with multiple-damping design response spectra

    International Nuclear Information System (INIS)

    Lilhanand, K.; Tseng, W.S.

    1987-01-01

    Seismic design of nuclear power plants as currently practiced requires time history analyses be performed to generate floor response spectra for seismic qualification of piping, equipment, and components. Since design response spectra are normally prescribed in the form of smooth spectra, the generation of synthetic time histories whose response spectra closely match the ''target'' design spectra of multiple damping values, is often required for the seismic time history analysis purpose. Various methods of generation of synthetic time histories compatible with target response spectra have been proposed in the literature. Since the mathematical problem of determining a time history from a given set of response spectral values is not unique, an exact solution is not possible, and all the proposed methods resort to some forms of approximate solutions. In this paper, a new iteration scheme, is described which effectively removes the difficulties encountered by the existing methods. This new iteration scheme can not only improve the accuracy of spectrum matching for a single-damping target spectrum, but also automate the spectrum matching for multiple-damping target spectra. The applicability and limitations as well as the method adopted to improve the numerical stability of this new iteration scheme are presented. The effectiveness of this new iteration scheme is illustrated by two example applications

  7. Study on time response properties of ionization chamber in profile gauge

    International Nuclear Information System (INIS)

    Wang Zhentao; Shen Yixiong; Wang Liqiang; Hao Pengfei

    2011-01-01

    The drift time of ions in the ionization chamber was measured by means of using a shortly pulsed X-ray device and through analyzing the voltage signals on the load resistor of the chamber recorded by a digital oscilloscope. By using this method, the time response properties of the ionization chamber in the profile gauge were studied, results of ion drift time for ionization chambers with different internal structures, different voltages and different gas pressures were introduced and the sources of error were discussed. The experiment results show that the time response of ionization chamber in profile gauge meets the requirement of on-line hot strip measuring. (authors)

  8. TECHNICAL COORDINATION

    CERN Multimedia

    A. Ball and W. Zeuner

    2012-01-01

      In the reporting period, CMS has collected about 10 fb–1 of pp collision data. Considering the prolonged duration of the current running period, with no opportunity for thorough maintenance since 2009, the reliability of the infrastructure and common systems was satisfactory. . Once again, CMS was fortunate that some failures coincided with LHC downtime, avoiding major data losses. After repeated difficulties over the summer with reconnection of the cold box following an unexpected stop, the procedure was revised. For reliability, and to reduce the risk of a fast discharge, the reconnection is now done at a reduced field of 2 T, resulting in a mechanical on-off-on cycle. It is also time consuming, with two times two hours for the ramp-down/up and several hours for refilling the He dewar before restoring the field to 3.8 T. In response to this, a mode of operation has been successfully tested that allows doubling the refill rate of the dewar. Reconnection at a somewhat higher field is ...

  9. Review of resistance temperature detector time response characteristics. Safety evaluation report

    International Nuclear Information System (INIS)

    1981-08-01

    A Resistance Temperature Detector (RTD) is used extensively for monitoring water temperatures in nuclear reactor plants. The RTD element does not respond instantaneously to changes in water temperature, but rather there is a time delay before the element senses the temperature change, and in nuclear reactors this delay must be factored into the computation of safety setpoints. For this reason it is necessary to have an accurate description of the RTD time response. This report is a review of the current state of the art of describing and measuring this time response

  10. Performing dynamic time history analyses by extension of the response spectrum method

    International Nuclear Information System (INIS)

    Hulbert, G.M.

    1983-01-01

    A method is presented to calculate the dynamic time history response of finite-element models using results from response spectrum analyses. The proposed modified time history method does not represent a new mathamatical approach to dynamic analysis but suggests a more efficient ordering of the analytical equations and procedures. The modified time history method is considerably faster and less expensive to use than normal time hisory methods. This paper presents the theory and implementation of the modified time history approach along with comparisons of the modified and normal time history methods for a prototypic seismic piping design problem

  11. 48 CFR 5.203 - Publicizing and response time.

    Science.gov (United States)

    2010-10-01

    ... development if the proposed contract action is expected to exceed the simplified acquisition threshold. (f) Nothing in this subpart prohibits officers or employees of agencies from responding to requests for... response times specified in paragraphs (a) through (d) of this section. Upon learning that a particular...

  12. Effects of acute urinary bladder overdistension on bladder response during sacral neurostimulation.

    Science.gov (United States)

    Bross, S; Schumacher, S; Scheepe, J R; Zendler, S; Braun, P M; Alken, P; Jünemann, K

    1999-10-01

    Urinary retention and micturition disorders after overdistension are clinically well-known complications of subvesical obstruction. We attempted to evaluate whether bladder overdistension influences bladder response and whether overdistension supports detrusor decompensation. Following lumbal laminectomy in 9 male foxhounds, the sacral anterior roots S2 and S3 were placed into a modified Brindley electrode for reproducible and controlled detrusor activation. The bladder was filled in stages of 50 ml from 0 to 700 ml, corresponding to an overdistension. At each volume, the bladder response during sacral anterior root stimulation was registered. After overdistension, the bladder was refilled stepwise from 0 to 300 ml and stimulated. In all dogs, the bladder response was influenced by the intravesical volume. The maximum pressure (mean 69.1 cm H(2)O) was observed at mean volume of 100 ml. During overdistension, a significant reduction in bladder response of more than 80% was seen. After overdistension, a significant reduction in intravesical pressure of 19.0% was observed. In 2 cases, reduction in bladder response was more than 50% after a single overdistension. We conclude that motoric bladder function is influenced during and after overdistension. A single bladder overdistension can support acute and long-lasting detrusor decompensation. In order to protect motoric bladder function, bladder overdistension must be prevented.

  13. A new method for measuring the response time of the high pressure ionization chamber

    International Nuclear Information System (INIS)

    Wang, Zhentao; Shen, Yixiong; An, Jigang

    2012-01-01

    Time response is an important performance characteristic for gas-pressurized ionization chambers. To study the time response, it is especially crucial to measure the ion drift time in high pressure ionization chambers. In this paper, a new approach is proposed to study the ion drift time in high pressure ionization chambers. It is carried out with a short-pulsed X-ray source and a high-speed digitizer. The ion drift time in the chamber is then determined from the digitized data. By measuring the ion drift time of a 15 atm xenon testing chamber, the method has been proven to be effective in the time response studies of ionization chambers. - Highlights: ► A method for measuring response time of high pressure ionization chamber is proposed. ► A pulsed X-ray producer and a digital oscilloscope are used in the method. ► The response time of a 15 atm Xenon testing ionization chamber has been measured. ► The method has been proved to be simple, feasible and effective.

  14. Effect of hip braces on brake response time: Repeated measures designed study.

    Science.gov (United States)

    Dammerer, Dietmar; Waidmann, Cornelia; Huber, Dennis G; Krismer, Martin; Haid, Christian; Liebensteiner, Michael C

    2017-08-01

    The question whether or not a patient with a hip brace should drive a car is of obvious importance because the advice given to patients to resume driving is often anecdotal as few scientific data are available on this specific subject. To assess driving ability (brake response time) with commonly used hip braces. Repeated measures design. Brake response time was assessed under six conditions: (1) without a brace (control), (2) with a typical postoperative hip brace with adjustable range of motion and the settings: unrestricted, (3) flexion limited to 70°, (4) extension blocked at 20° hip flexion, (5) both flexion and extension limited (20°/70°) and (6) an elastic hip bandage. Brake response time was assessed using a custom-made driving simulator as used in previous studies. The participants were a convenience sample of able-bodied participants. A total of 70 participants (35 women and 35 men) participated in our study. Mean age was 31.1 (standard deviation: 10.6; range: 21.7-66.4) years. A significant within-subject effect for brake response time was found ( p = 0.009), but subsequent post hoc analyses revealed no significant differences between control and the other settings. Based on our findings, it does not seem mandatory to recommend driving abstinence for patients wearing a hip orthosis. We suggest that our results be interpreted with caution, because (1) an underlying pathological hip condition needs to be considered, (2) the ability to drive a car safely is multifactorial and brake response time is only one component thereof and (3) brake response time measurements were performed only with healthy participants. Clinical relevance Hip braces are used in the context of joint-preserving and prosthetic surgery of the hip. Therefore, clinicians are confronted with the question whether to allow driving a car with the respective hip brace or not. Our data suggest that hip braces do not impair brake response time.

  15. On response time and cycle time distributions in a two-stage cyclic queue

    NARCIS (Netherlands)

    Boxma, O.J.; Donk, P.

    1982-01-01

    We consider a two-stage closed cyclic queueing model. For the case of an exponential server at each queue we derive the joint distribution of the successive response times of a custumer at both queues, using a reversibility argument. This joint distribution turns out to have a product form. The

  16. Searching for serial refreshing in working memory: Using response times to track the content of the focus of attention over time.

    Science.gov (United States)

    Vergauwe, Evie; Hardman, Kyle O; Rouder, Jeffrey N; Roemer, Emily; McAllaster, Sara; Cowan, Nelson

    2016-12-01

    One popular idea is that, to support the maintenance of a set of elements over brief periods of time, the focus of attention rotates among the different elements, thereby serially refreshing the content of working memory (WM). In the research reported here, probe letters were presented between to-be-remembered letters, and response times to these probes were used to infer the status of the different items in WM. If the focus of attention cycles from one item to the next, its content should be different at different points in time, and this should be reflected in a change in the response time patterns over time. Across a set of four experiments, we demonstrated a striking pattern of invariance in the response time patterns over time, suggesting either that the content of the focus of attention did not change over time or that response times cannot be used to infer the content of the focus of attention. We discuss how this pattern constrains models of WM, attention, and human information processing.

  17. Changes in the Social Responsibility Attitudes of Engineering Students Over Time.

    Science.gov (United States)

    Bielefeldt, Angela R; Canney, Nathan E

    2016-10-01

    This research explored how engineering student views of their responsibility toward helping individuals and society through their profession, so-called social responsibility, change over time. A survey instrument was administered to students initially primarily in their first year, senior year, or graduate studies majoring in mechanical, civil, or environmental engineering at five institutions in September 2012, April 2013, and March 2014. The majority of the students (57 %) did not change significantly in their social responsibility attitudes, but 23 % decreased and 20 % increased. The students who increased, decreased, or remained the same in their social responsibility attitudes over time did not differ significantly in terms of gender, academic rank, or major. Some differences were found between institutions. Students who decreased in social responsibility initially possessed more positive social responsibility attitudes, were less likely to indicate that college courses impacted their views of social responsibility, and were more likely to have decreased in the frequency that they participated in volunteer activities, compared to students who did not change or increased their social responsibility. Although the large percentage of engineering students who decreased their social responsibility during college was disappointing, it is encouraging that courses and participation in volunteer activities may combat this trend.

  18. Optimal time interval for induction of immunologic adaptive response

    International Nuclear Information System (INIS)

    Ju Guizhi; Song Chunhua; Liu Shuzheng

    1994-01-01

    The optimal time interval between prior dose (D1) and challenge dose (D2) for the induction of immunologic adaptive response was investigated. Kunming mice were exposed to 75 mGy X-rays at a dose rate of 12.5 mGy/min. 3, 6, 12, 24 or 60 h after the prior irradiation the mice were challenged with a dose of 1.5 Gy at a dose rate of 0.33 Gy/min. 18h after D2, the mice were sacrificed for examination of immunological parameters. The results showed that with an interval of 6 h between D1 and D2, the adaptive response of the reaction of splenocytes to LPS was induced, and with an interval of 12 h the adaptive responses of spontaneous incorporation of 3 H-TdR into thymocytes and the reaction of splenocytes to Con A and LPS were induced with 75 mGy prior irradiation. The data suggested that the optimal time intervals between D1 and D2 for the induction of immunologic adaptive response were 6 h and 12 h with a D1 of 75 mGy and a D2 of 1.5 Gy. The mechanism of immunologic adaptation following low dose radiation is discussed

  19. Response Times of Operators in a Control Room

    DEFF Research Database (Denmark)

    Platz, O.; Rasmussen, Jens; Skanborg, Preben Zacho

    A statistical analysis was made of operator response times recorded in the control room of a research reactor during the years 1972-1974. A homogeneity test revealed that the data consist of a mixture of populations. A small but statistically significant difference is found between day and night...

  20. Development of a geometry-compensated neutron time-of-flight detector for ICF applications with approximately 200 ps time response

    International Nuclear Information System (INIS)

    Murphy, T.J.; Lerche, R.A.

    1992-01-01

    Current-mode neutron time-of-flight detectors are used on Nova for neutron yield, ion temperature, and neutron emission time measurements. Currently used detectors are limited by the time response of the microchannel plate photomultiplier tubes used with the scintillators, scintillator decay time, scintillator thickness, and oscilloscope response time. A change in the geometry of the scintillator allows one to take advantage of the increased time resolution made possible by more advanced transient recorders and microchannel plate photomultiplier tubes. A prototype detector has been designed to incorporate these changes, and could potentially yield time resolution of less than 150 ps. Experimental results are presented demonstrating an ion temperature measurement of a direct-drive DT implosion on Nova

  1. Electromagnet Response Time Tests on Primary CRDM of a Prototype Gen-IV SFR

    International Nuclear Information System (INIS)

    Lee, Jae-Han; Koo, Gyeong-Hoi

    2015-01-01

    This paper identifies the electromagnetic response characteristics of the electromagnet of a primary control rod drive mechanism (CRDM) used for the reactor scram function. The test measures the electromagnet response time required to release an armature from a stator controlled by a loss of an electromagnetic force on an armature after shorting a power supply to an electromagnet coil. These tests are carried out while changing the electromagnet core material, an assist spring, and an armature holding current. The main factors influencing the test parameters on the response are found to be the armature holding current for holding the armature loads, and the material type of the electromagnet cores. The minimum response time is 0.13 seconds in the case of using SS410 material as an armature, while the S10C material as an armature has a response time of 0.21 seconds. Electromagnet response time characteristics from the test results will be evaluated by comparing the precise moving data of an electromagnet armature through the use of a high-speed camera and a potentiometer in the future

  2. Time history nonlinear earthquake response analysis considering materials and geometrical nonlinearity

    International Nuclear Information System (INIS)

    Kobayashi, T.; Yoshikawa, K.; Takaoka, E.; Nakazawa, M.; Shikama, Y.

    2002-01-01

    A time history nonlinear earthquake response analysis method was proposed and applied to earthquake response prediction analysis for a Large Scale Seismic Test (LSST) Program in Hualien, Taiwan, in which a 1/4 scale model of a nuclear reactor containment structure was constructed on sandy gravel layer. In the analysis both of strain-dependent material nonlinearity, and geometrical nonlinearity by base mat uplift, were considered. The 'Lattice Model' for the soil-structure interaction model was employed. An earthquake record on soil surface at the site was used as control motion, and deconvoluted to the input motion of the analysis model at GL-52 m with 300 Gal of maximum acceleration. The following two analyses were considered: (A) time history nonlinear, (B) equivalent linear, and the advantage of time history nonlinear earthquake response analysis method is discussed

  3. Consumer responses to time varying prices for electricity

    International Nuclear Information System (INIS)

    Thorsnes, Paul; Williams, John; Lawson, Rob

    2012-01-01

    We report new experimental evidence of the household response to weekday differentials in peak and off-peak electricity prices. The data come from Auckland, New Zealand, where peak residential electricity consumption occurs in winter for heating. Peak/off-peak price differentials ranged over four randomly selected groups from 1.0 to 3.5. On average, there was no response except in winter. In winter, participant households reduced electricity consumption by at least 10%, took advantage of lower off-peak prices but did not respond to the peak price differentials. Response varied with house and household size, time spent away from home, and whether water was heated with electricity. - Highlights: ► Seasonal effects in winter. ► High conservation effect from information. ► Higher peak prices no effect on peak use. ► Low off-peak prices encourage less conservation off-peak.

  4. Analytical Call Center Model with Voice Response Unit and Wrap-Up Time

    Directory of Open Access Journals (Sweden)

    Petr Hampl

    2015-01-01

    Full Text Available The last twenty years of computer integration significantly changed the process of service in a call center service systems. Basic building modules of classical call centers – a switching system and a group of humans agents – was extended with other special modules such as skills-based routing module, automatic call distribution module, interactive voice response module and others to minimize the customer waiting time and wage costs. A calling customer of a modern call center is served in the first stage by the interactive voice response module without any human interaction. If the customer requirements are not satisfied in the first stage, the service continues to the second stage realized by the group of human agents. The service time of second stage – the average handle time – is divided into a conversation time and wrap-up time. During the conversation time, the agent answers customer questions and collects its requirements and during the wrap-up time (administrative time the agent completes the task without any customer interaction. The analytical model presented in this contribution is solved under the condition of statistical equilibrium and takes into account the interactive voice response module service time, the conversation time and the wrap-up time.

  5. Comparative study of on-line response time measurement methods for platinum resistance thermometer

    International Nuclear Information System (INIS)

    Zwingelstein, G.; Gopal, R.

    1979-01-01

    This study deals with the in site determination of the response time of platinum resistance sensor. In the first part of this work, two methods furnishing the reference response time of the sensors are studied. In the second part of the work, two methods obtaining the response time without dismounting of the sensor, are studied. A comparative study of the performances of these methods is included for fluid velocities varying from 0 to 10 m/sec, in both laboratory and plant conditions

  6. Response of orthotropic micropolar elastic medium due to time ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    namic response of anisotropic continuum has received the attention of ... linear theory of micropolar elasticity and bending of orthotropic micropolar ... medium due to time harmonic concentrated load, the continuum is divided into two half-.

  7. Towards best-case response times of real-time tasks under fixed-priority scheduling with deferred preemption

    NARCIS (Netherlands)

    Bril, R.J.; Verhaegh, W.F.J.; Puaut, I.

    2005-01-01

    In this paper, we present lower bounds for best-case response times of periodic tasks under fixed-priority scheduling with deferred preemption (FPDS) and arbitrary phasing. Our analysis is based on a dedicated conjecture for a ¿-optimal instant, and uses the notion of best-case occupied time. We

  8. An Analysis of Variance Approach for the Estimation of Response Time Distributions in Tests

    Science.gov (United States)

    Attali, Yigal

    2010-01-01

    Generalizability theory and analysis of variance methods are employed, together with the concept of objective time pressure, to estimate response time distributions and the degree of time pressure in timed tests. By estimating response time variance components due to person, item, and their interaction, and fixed effects due to item types and…

  9. The link between response time and preference, variance and processing heterogeneity in stated choice experiments

    DEFF Research Database (Denmark)

    Campbell, Danny; Mørkbak, Morten Raun; Olsen, Søren Bøye

    2018-01-01

    In this article we utilize the time respondents require to answer a self-administered online stated preference survey. While the effects of response time have been previously explored, this article proposes a different approach that explicitly recognizes the highly equivocal relationship between ...... between response time and utility coefficients, error variance and processing strategies. Our results thus emphasize the importance of considering response time when modeling stated choice data....... response time and respondents' choices. In particular, we attempt to disentangle preference, variance and processing heterogeneity and explore whether response time helps to explain these three types of heterogeneity. For this, we divide the data (ordered by response time) into approximately equal......-sized subsets, and then derive different class membership probabilities for each subset. We estimate a large number of candidate models and subsequently conduct a frequentist-based model averaging approach using information criteria to derive weights of evidence for each model. Our findings show a clear link...

  10. Hatching response to temperature along a latitudinal gradient by the fairy shrimp Branchinecta lindahli (Crustacea; Branchiopoda; Anostraca in culture conditions

    Directory of Open Access Journals (Sweden)

    D. Christopher Rogers

    2014-08-01

    Full Text Available Branchinecta lindahli is a broadly distributed fairy shrimp, reported from a range of temporary wetland habitat types in arid western North America. This species’ eggs hatch after the habitat dries, refills from seasonal rain, and receives a strong cold shock during the winter low temperatures. I studied phenotypic variation in temperature responses in cultures collected from four populations across 8° of latitude with low average temperatures ranging from -8 to 8°C. Time to maturation, mature body size and first clutch size decreased, as temperature increased, with only minor body size variability at mortality, regardless of culture origin. No variation in individual egg size was observed, demonstrating that body size is sacrificed to produce at least a few normal eggs during unfavourable years. Latitudinal variation in hatching temperature demonstrated a pattern of adaptive significance, with some overlap between regional temperature hatching cues.  Phenotypic hatching temperature and growth rate responses may cause genetic segregation, selecting one cohort for warmer, dryer years and one cohort for cooler, wetter years.  Drier year selected cohorts can exploit habitats that have shorter hydroperiods even in wet years. This may lead to population specialisation and speciation by adapting to more extreme habitats

  11. Sensor response monitoring in pressurized water reactors using time series modeling

    International Nuclear Information System (INIS)

    Upadhyaya, B.R.; Kerlin, T.W.

    1978-01-01

    Random data analysis in nuclear power reactors for purposes of process surveillance, pattern recognition and monitoring of temperature, pressure, flow and neutron sensors has gained increasing attention in view of their potential for helping to ensure safe plant operation. In this study, application of autoregressive moving-average (ARMA) time series modeling for monitoring temperature sensor response characteristrics is presented. The ARMA model is used to estimate the step and ramp response of the sensors and the related time constant and ramp delay time. The ARMA parameters are estimated by a two-stage algorithm in the spectral domain. Results of sensor testing for an operating pressurized water reactor are presented. 16 refs

  12. Capillary Refill using Augmented Reality

    OpenAIRE

    Clausen, Christoffer

    2017-01-01

    Master's thesis in Computer science The opportunities within augmented reality is growing. Augmented reality is a combination of the real and the virtual world in real time, and large companies like Microsoft and Google is now investing heavily in the technology. This thesis presents a solution for simulating a medical test called capillary refill, by using augmented reality. The simulation is performed with an augmented reality headset called HoloLens. The HoloLens will recognise a mark...

  13. Principal response curves: analysis of time-dependent multivariate responses of biological community to stress

    NARCIS (Netherlands)

    Brink, van den P.J.; Braak, ter C.J.F.

    1999-01-01

    In this paper a novel multivariate method is proposed for the analysis of community response data from designed experiments repeatedly sampled in time. The long-term effects of the insecticide chlorpyrifos on the invertebrate community and the dissolved oxygen (DO)–pH–alkalinity–conductivity

  14. Time response characteristics of X-ray detector system on Silex-Ⅰ laser facility

    International Nuclear Information System (INIS)

    Yi Rongqing; He Xiao'an; Li Hang; Du Huabing; Zhang Haiying; Cao Zhurong

    2013-01-01

    On the Silex-Ⅰ laser facility, the time response characteristics of XRD detector were studied. A laser with a pulse of 32 fs and a wavelength of 800 nm was used to irradiate a plane Au target. X-ray calibrated method of time of exposure X-ray framing camera and time resolution of X-ray streak camera was explored. The time response characteristics of XRD detector and time process of X-ray emission were obtained from experiment. We obtained X-ray calibration method of time of exposure X-ray framing camera and time resolution of X-ray streak camera. (authors)

  15. Motor preparation is modulated by the resolution of the response timing information.

    Science.gov (United States)

    Carlsen, Anthony N; Mackinnon, Colum D

    2010-03-31

    In the present experiment, the temporal predictability of response time was systematically manipulated to examine its effect on the time course of motor pre-programming and release of the intended movement by an acoustic startle stimulus. Participants performed a ballistic right wrist extension task in four different temporal conditions: 1) a variable foreperiod simple RT task, 2) a fixed foreperiod simple RT task, 3) a low resolution countdown anticipation-timing task, and 4) a high resolution anticipation-timing task. For each task, a startling acoustic stimulus (124dB) was presented at several intervals prior to the "go" signal ("go" -150ms, -500ms, and -1500ms). Results from the startle trials showed that the time course of movement pre-programming was affected by the temporal uncertainty of the imperative "go" cue. These findings demonstrate that the resolution of the timing information regarding the response cue has a marked effect on the timing of movement preparation such that under conditions of low temporal resolution, participants plan the movement well in advance in accordance with the anticipated probability of onset of the cue, whereas movement preparation is delayed until less than 500ms prior to response time when continuous temporal information is provided. Copyright 2010 Elsevier B.V. All rights reserved.

  16. Time response prediction of Brazilian Nuclear Power Plant temperature sensors using neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Roberto Carlos dos; Pereira, Iraci Martinez, E-mail: rcsantos@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    This work presents the results of the time constants values predicted from ANN using Angra I Brazilian nuclear power plant data. The signals obtained from LCSR loop current step response test sensors installed in the process presents noise end fluctuations that are inherent of operational conditions. Angra I nuclear power plant has 20 RTDs as part of the protection reactor system. The results were compared with those obtained from traditional way. Primary coolant RTDs (Resistance Temperature Detector) typically feed the plant's control and safety systems and must, therefore, be very accurate and have good dynamic performance. An in-situ test method called LCSR - loop current step response test was developed to measure remotely the response time of RTDs. In the LCSR method, the response time of the sensor is identified by means of the LCSR transformation that involves the dynamic response modal time constants determination using a nodal heat transfer model. For this reason, this calculation is not simple and requires specialized personnel. This work combines the two methodologies, Plunge test and LCSR test, using neural networks. With the use of neural networks it will not be necessary to use the LCSR transformation to determine sensor's time constant and this leads to more robust results. (author)

  17. Time response prediction of Brazilian Nuclear Power Plant temperature sensors using neural networks

    International Nuclear Information System (INIS)

    Santos, Roberto Carlos dos; Pereira, Iraci Martinez

    2011-01-01

    This work presents the results of the time constants values predicted from ANN using Angra I Brazilian nuclear power plant data. The signals obtained from LCSR loop current step response test sensors installed in the process presents noise end fluctuations that are inherent of operational conditions. Angra I nuclear power plant has 20 RTDs as part of the protection reactor system. The results were compared with those obtained from traditional way. Primary coolant RTDs (Resistance Temperature Detector) typically feed the plant's control and safety systems and must, therefore, be very accurate and have good dynamic performance. An in-situ test method called LCSR - loop current step response test was developed to measure remotely the response time of RTDs. In the LCSR method, the response time of the sensor is identified by means of the LCSR transformation that involves the dynamic response modal time constants determination using a nodal heat transfer model. For this reason, this calculation is not simple and requires specialized personnel. This work combines the two methodologies, Plunge test and LCSR test, using neural networks. With the use of neural networks it will not be necessary to use the LCSR transformation to determine sensor's time constant and this leads to more robust results. (author)

  18. Time domain simulation of the response of geometrically nonlinear panels subjected to random loading

    Science.gov (United States)

    Moyer, E. Thomas, Jr.

    1988-01-01

    The response of composite panels subjected to random pressure loads large enough to cause geometrically nonlinear responses is studied. A time domain simulation is employed to solve the equations of motion. An adaptive time stepping algorithm is employed to minimize intermittent transients. A modified algorithm for the prediction of response spectral density is presented which predicts smooth spectral peaks for discrete time histories. Results are presented for a number of input pressure levels and damping coefficients. Response distributions are calculated and compared with the analytical solution of the Fokker-Planck equations. RMS response is reported as a function of input pressure level and damping coefficient. Spectral densities are calculated for a number of examples.

  19. Response-only modal identification using random decrement algorithm with time-varying threshold level

    International Nuclear Information System (INIS)

    Lin, Chang Sheng; Tseng, Tse Chuan

    2014-01-01

    Modal Identification from response data only is studied for structural systems under nonstationary ambient vibration. The topic of this paper is the estimation of modal parameters from nonstationary ambient vibration data by applying the random decrement algorithm with time-varying threshold level. In the conventional random decrement algorithm, the threshold level for evaluating random dec signatures is defined as the standard deviation value of response data of the reference channel. The distortion of random dec signatures may be, however, induced by the error involved in noise from the original response data in practice. To improve the accuracy of identification, a modification of the sampling procedure in random decrement algorithm is proposed for modal-parameter identification from the nonstationary ambient response data. The time-varying threshold level is presented for the acquisition of available sample time history to perform averaging analysis, and defined as the temporal root-mean-square function of structural response, which can appropriately describe a wide variety of nonstationary behaviors in reality, such as the time-varying amplitude (variance) of a nonstationary process in a seismic record. Numerical simulations confirm the validity and robustness of the proposed modal-identification method from nonstationary ambient response data under noisy conditions.

  20. Response Time Analysis and Test of Protection System Instrument Channels for APR1400 and OPR1000

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Jae; Han, Seung; Yun, Jae Hee; Baek, Seung Min [Department of Instrumentation and Control System Engineering, KEPCO Engineering and Construction, Daejeon (Korea, Republic of); Lee, Sang Jeong [Department of Electronics Engineering, Chungnam National University, Daejeon (Korea, Republic of)

    2015-07-01

    Safety limits are required to maintain the integrity of physical barriers designed to prevent the uncontrolled release of radioactive materials in nuclear power plants. The safety analysis establishes two critical constraints that include an analytical limit in terms of a measured or calculated variable, and a specific time after the analytical limit is reached to begin protective action. Keeping with the nuclear regulations and industry standards, satisfying these two requirements will ensure that the safety limit will not be exceeded during the design basis event, either an anticipated operational occurrence or a postulated accident. Various studies on the setpoint determination methodology for the safety-related instrumentation have been actively performed to ensure that the requirement of the analytical limit is satisfied. In particular, the protection setpoint methodology for the advanced power reactor 1400 (APP1400) and the optimized power reactor 1000 (OPR1000) has been recently developed to cover both the design basis event and the beyond design basis event. The developed setpoint methodology has also been quantitatively validated using specific computer programs and setpoint calculations. However, the safety of nuclear power plants cannot be fully guaranteed by satisfying the requirement of the analytical limit. In spite of the response time verification requirements of nuclear regulations and industry standards, it is hard to find the studies on the systematically integrated methodology regarding the response time evaluation. In cases of APR1400 and OPR1000, the response time analysis for the plant protection system is partially included in the setpoint calculation and the response time test is separately performed via the specific plant procedure. The test technique has a drawback which is the difficulty to demonstrate completeness of timing test. The analysis technique has also a demerit of resulting in extreme times that not actually possible. Thus

  1. Response Time Analysis and Test of Protection System Instrument Channels for APR1400 and OPR1000

    International Nuclear Information System (INIS)

    Lee, Chang Jae; Han, Seung; Yun, Jae Hee; Baek, Seung Min; Lee, Sang Jeong

    2015-01-01

    Safety limits are required to maintain the integrity of physical barriers designed to prevent the uncontrolled release of radioactive materials in nuclear power plants. The safety analysis establishes two critical constraints that include an analytical limit in terms of a measured or calculated variable, and a specific time after the analytical limit is reached to begin protective action. Keeping with the nuclear regulations and industry standards, satisfying these two requirements will ensure that the safety limit will not be exceeded during the design basis event, either an anticipated operational occurrence or a postulated accident. Various studies on the setpoint determination methodology for the safety-related instrumentation have been actively performed to ensure that the requirement of the analytical limit is satisfied. In particular, the protection setpoint methodology for the advanced power reactor 1400 (APP1400) and the optimized power reactor 1000 (OPR1000) has been recently developed to cover both the design basis event and the beyond design basis event. The developed setpoint methodology has also been quantitatively validated using specific computer programs and setpoint calculations. However, the safety of nuclear power plants cannot be fully guaranteed by satisfying the requirement of the analytical limit. In spite of the response time verification requirements of nuclear regulations and industry standards, it is hard to find the studies on the systematically integrated methodology regarding the response time evaluation. In cases of APR1400 and OPR1000, the response time analysis for the plant protection system is partially included in the setpoint calculation and the response time test is separately performed via the specific plant procedure. The test technique has a drawback which is the difficulty to demonstrate completeness of timing test. The analysis technique has also a demerit of resulting in extreme times that not actually possible. Thus

  2. Transducer frequency response variations investigated by time reversal calibration

    Czech Academy of Sciences Publication Activity Database

    Kober, Jan; Převorovský, Zdeněk

    2016-01-01

    Roč. 26, č. 2 (2016), A16-A16 ISSN 1213-3825. [Europen Conference on Acoustic Emission Testing /32./. 07.09.2016-09.09.2016, Praha] Institutional support: RVO:61388998 Keywords : calibration * time reversal * transducer * frequency response Subject RIV: BI - Acoustics

  3. Modeling Climate Responses to Spectral Solar Forcing on Centennial and Decadal Time Scales

    Science.gov (United States)

    Wen, G.; Cahalan, R.; Rind, D.; Jonas, J.; Pilewskie, P.; Harder, J.

    2012-01-01

    We report a series of experiments to explore clima responses to two types of solar spectral forcing on decadal and centennial time scales - one based on prior reconstructions, and another implied by recent observations from the SORCE (Solar Radiation and Climate Experiment) SIM (Spectral 1rradiance Monitor). We apply these forcings to the Goddard Institute for Space Studies (GISS) Global/Middle Atmosphere Model (GCMAM). that couples atmosphere with ocean, and has a model top near the mesopause, allowing us to examine the full response to the two solar forcing scenarios. We show different climate responses to the two solar forCing scenarios on decadal time scales and also trends on centennial time scales. Differences between solar maximum and solar minimum conditions are highlighted, including impacts of the time lagged reSponse of the lower atmosphere and ocean. This contrasts with studies that assume separate equilibrium conditions at solar maximum and minimum. We discuss model feedback mechanisms involved in the solar forced climate variations.

  4. Response Time Test for The Application of the Data Communication Network to Nuclear Power Plant

    International Nuclear Information System (INIS)

    Shin, Y.C.; Lee, J.Y.; Park, H.Y.; Seong, S.H.; Chung, H.Y.

    2002-01-01

    This paper discusses the response time test for the application of the Data Communication Network (DCN) to Nuclear Power Plant (NPP). Conventional Instrumentation and Control (I and C) Systems using the analog technology in NPP have raised many problems regarding the lack of spare parts, maintenance burden, inaccuracy, etc.. In order to solve the problems, the Korean Next Generation Reactor (KNGR) I and C system has adopted the digital technology and new design features of using the data communication networks. It is essential to prove the response time requirements that arise from the introduction of digital I and C technology and data communication networks to nuclear power plant design. For the response time test, a high reliable data communication network structure has been developed to meet the requirements of redundancy, diversity, and segmentation. This paper presents the results of network load analysis and response time test for the KNGR DCN prototype. The test has been focused on the response time from the field components to the gateway because the response times from the gateway to the specific systems are similar to those of the existing design. It is verified that the response time requirements are met through the prototype test for KNGR I and C systems. (authors)

  5. Time delays between core power production and external detector response from Monte Carlo calculations

    International Nuclear Information System (INIS)

    Valentine, T.E.; Mihalczo, J.T.

    1996-01-01

    One primary concern for design of safety systems for reactors is the time response of external detectors to changes in the core. This paper describes a way to estimate the time delay between the core power production and the external detector response using Monte Carlo calculations and suggests a technique to measure the time delay. The Monte Carlo code KENO-NR was used to determine the time delay between the core power production and the external detector response for a conceptual design of the Advanced Neutron Source (ANS) reactor. The Monte Carlo estimated time delay was determined to be about 10 ms for this conceptual design of the ANS reactor

  6. Femtosecond response time measurements of a Cs2Te photocathode

    Science.gov (United States)

    Aryshev, A.; Shevelev, M.; Honda, Y.; Terunuma, N.; Urakawa, J.

    2017-07-01

    Success in design and construction of a compact, high-brightness accelerator system is strongly related to the production of ultra-short electron beams. Recently, the approach to generate short electron bunches or pre-bunched beams in RF guns directly illuminating a high quantum efficiency semiconductor photocathode with femtosecond laser pulses has become attractive. The measurements of the photocathode response time in this case are essential. With an approach of the interferometer-type pulse splitter deep integration into a commercial Ti:Sa laser system used for RF guns, it has become possible to generate pre-bunched electron beams and obtain continuously variable electron bunch separation. In combination with a well-known zero-phasing technique, it allows us to estimate the response time of the most commonly used Cs2Te photocathode. It was demonstrated that the peak-to-peak rms time response of Cs2Te is of the order of 370 fs, and thereby, it is possible to generate and control a THz sequence of relativistic electron bunches by a conventional S-band RF gun. This result can also be applied for investigation of other cathode materials and electron beam temporal shaping and further opens a possibility to construct wide-range tunable, table-top THz free electron laser.

  7. Determination of response time of resistance thermometers by in situ measurements

    International Nuclear Information System (INIS)

    Goncalves, I.M.P.; Soares, A.J.

    1986-01-01

    The loop-current-step-response test provides a mean for determining the time constant of resistance thermometers. The test consists in heating the sensor a few degrees above ambient temperature by causing a step perurbation in the electric current that flows through the sensor leads. The developed mathematical transformation permits to use data collected during the internal heating transient to predict the sensor response to perturbations in fluid temperature. Experimental data obtained show that time constant determined by this method is within 15 percent of the true value. (Author) [pt

  8. Improved response time of flexible microelectromechanical sensors employing eco-friendly nanomaterials.

    Science.gov (United States)

    Fan, Shicheng; Dan, Li; Meng, Lingju; Zheng, Wei; Elias, Anastasia; Wang, Xihua

    2017-11-09

    Flexible force/pressure sensors are of interest for academia and industry and have applications in wearable technologies. Most of such sensors on the market or reported in journal publications are based on the operation mechanism of probing capacitance or resistance changes of the materials under pressure. Recently, we reported the microelectromechanical (MEM) sensors based on a different mechanism: mechanical switches. Multiples of such MEM sensors can be integrated to achieve the same function of regular force/pressure sensors while having the advantages of ease of fabrication and long-term stability in operation. Herein, we report the dramatically improved response time (more than one order of magnitude) of these MEM sensors by employing eco-friendly nanomaterials-cellulose nanocrystals. For instance, the incorporation of polydimethysiloxane filled with cellulose nanocrystals shortened the response time of MEM sensors from sub-seconds to several milliseconds, leading to the detection of both diastolic and systolic pressures in the radial arterial blood pressure measurement. Comprehensive mechanical and electrical characterization of the materials and the devices reveal that greatly enhanced storage modulus and loss modulus play key roles in this improved response time. The demonstrated fast-response flexible sensors enabled continuous monitoring of heart rate and complex cardiovascular signals using pressure sensors for future wearable sensing platforms.

  9. Performance on a simple response time task: Is sleep or work more important for miners?

    Science.gov (United States)

    Ferguson, Sally A; Paech, Gemma M; Dorrian, Jillian; Roach, Gregory D; Jay, Sarah M

    2011-01-01

    The purpose of the current study was to investigate the impact of work- and sleep-related factors on an objective measure of response time in a field setting. Thirty-five mining operators working 12-h shift patterns completed daily sleep and work diaries, wore activity monitors continuously and completed palm-based psychomotor vigilance tests (palmPVT) at the start and end of each shift. Linear mixed models were used to test the main effects on response time of roster, timing of test, sleep history and prior wake. The time at which the test occurred was a significant predictor of response time (F₃(,)₄₀₃(.)₄ = 6.72, p times than the start of night shifts, and the start or end of day shifts. Further, the amount of sleep obtained in the 24h prior to the test was also a significant predictor of response time (F₃(,)₄₀₇(.)₀ = 3.05, p time indicative of performance impairments. Of more interest however is that immediate sleep history was also predictive of changes in response time with lower amounts of prior sleep related to slower response times. The current data provides further evidence that sleep is a primary mediator of performance, independent of roster pattern. Copyright © 2010 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  10. Larger Neural Responses Produce BOLD Signals That Begin Earlier in Time

    Directory of Open Access Journals (Sweden)

    Serena eThompson

    2014-06-01

    Full Text Available Functional MRI analyses commonly rely on the assumption that the temporal dynamics of hemodynamic response functions (HRFs are independent of the amplitude of the neural signals that give rise to them. The validity of this assumption is particularly important for techniques that use fMRI to resolve sub-second timing distinctions between responses, in order to make inferences about the ordering of neural processes. Whether or not the detailed shape of the HRF is independent of neural response amplitude remains an open question, however. We performed experiments in which we measured responses in primary visual cortex (V1 to large, contrast-reversing checkerboards at a range of contrast levels, which should produce varying amounts of neural activity. Ten subjects (ages 22-52 were studied in each of two experiments using 3 Tesla scanners. We used rapid, 250 msec, temporal sampling (repetition time, or TR and both short and long inter-stimulus interval (ISI stimulus presentations. We tested for a systematic relationship between the onset of the HRF and its amplitude across conditions, and found a strong negative correlation between the two measures when stimuli were separated in time (long- and medium-ISI experiments, but not the short-ISI experiment. Thus, stimuli that produce larger neural responses, as indexed by HRF amplitude, also produced HRFs with shorter onsets. The relationship between amplitude and latency was strongest in voxels with lowest mean-normalized variance (i.e., parenchymal voxels. The onset differences observed in the longer-ISI experiments are likely attributable to mechanisms of neurovascular coupling, since they are substantially larger than reported differences in the onset of action potentials in V1 as a function of response amplitude.

  11. Predicting response times for the Spotify backend

    OpenAIRE

    Yanggratoke, Rerngvit; Kreitz, Gunnar; Goldmann, Mikael; Stadler, Rolf

    2012-01-01

    We model and evaluate the performance of a distributed key-value storage system that is part of the Spotify backend. Spotify is an on-demand music streaming service, offering low-latency access to a library of over 16 million tracks and serving over 10 million users currently. We first present a simplified model of the Spotify storage architecture, in order to make its analysis feasible. We then introduce an analytical model for the distribution of the response time, a key metric in the Spoti...

  12. Stroop interference and the timing of selective response activation.

    NARCIS (Netherlands)

    Lansbergen, M.M.; Kenemans, J.L.

    2008-01-01

    OBJECTIVE: To examine the exact timing of selective response activation in a manual color-word Stroop task. METHODS: Healthy individuals performed two versions of a manual color-word Stroop task, varying in the probability of incongruent color-words, while EEG was recorded. RESULTS: Stroop

  13. Time to Response to Citalopram Treatment for Agitation in Alzheimer Disease.

    Science.gov (United States)

    Weintraub, Daniel; Drye, Lea T; Porsteinsson, Anton P; Rosenberg, Paul B; Pollock, Bruce G; Devanand, Devangere P; Frangakis, Constantine; Ismail, Zahinoor; Marano, Christopher; Meinert, Curtis L; Mintzer, Jacobo E; Munro, Cynthia A; Pelton, Gregory; Rabins, Peter V; Schneider, Lon S; Shade, David M; Yesavage, Jerome; Lyketsos, Constantine G

    2015-11-01

    Agitation is a common and significant problem in Alzheimer disease (AD). In the recent Citalopram for Agitation in Alzheimer's Disease (CitAD) study, citalopram was efficacious for the treatment of AD agitation. Here we examined the time course and predictors of response to treatment. Response in CitAD was defined as a modified Alzheimer Disease Cooperative Study Clinical Global Impression of Change (CGIC) score of 1 or 2 or a Neurobehavioral Rating Scale agitation subscale (NBRS-A) score reduction ≥ 50% from baseline. "Stable early response" was defined as meeting the aforementioned criteria at both weeks 3 and 9, "late response" was response at week 9 but not at week 3, and "unstable response" was response at week 3 but not at week 9. In the primary analyses, citalopram was superior to placebo on both the CGIC and the NBRS-A response measures. Little between-group differences were found in response rates in the first 3 weeks of the study (21% versus 19% on the CGIC). Citalopram patients were more likely than placebo patients to be a late responder (18% versus 8% on CGIC, Fisher's exact p = 0.09; 31% versus 15% on NBRS-A, Fisher's exact p = 0.02). Approximately half of citalopram responders (45%-56%) at end of study achieved response later in the study compared with 30%-44% of placebo responders. Treatment with citalopram for agitation in AD needs to be at least 9 weeks in duration to allow sufficient time for full response. Study duration is an important factor to consider in the design of clinical trials for agitation in AD. Copyright © 2015 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.

  14. Dose-response association between leisure time physical activity and work ability

    DEFF Research Database (Denmark)

    Calatayud, Joaquin; Jakobsen, Markus D.; Sundstrup, Emil

    2015-01-01

    INTRODUCTION: Regular physical activity is important for longevity and health, but knowledge about the optimal dose of physical activity for maintaining good work ability is unknown. This study investigates the association between intensity and duration of physical activity during leisure time......, lifestyle and chronic disease showed that the duration of high-intensity physical activity during leisure was positively associated with work ability, in a dose-response fashion (p physical activity per week had on average 8 points higher work ability...... than those not performing such activities. The duration of low-intensity leisure-time physical activity was not associated with work ability (p = 0.5668). CONCLUSIONS: The duration of high-intensity physical activity during leisure time is associated in a dose-response fashion with work ability...

  15. Workload Capacity: A Response Time-Based Measure of Automation Dependence.

    Science.gov (United States)

    Yamani, Yusuke; McCarley, Jason S

    2016-05-01

    An experiment used the workload capacity measure C(t) to quantify the processing efficiency of human-automation teams and identify operators' automation usage strategies in a speeded decision task. Although response accuracy rates and related measures are often used to measure the influence of an automated decision aid on human performance, aids can also influence response speed. Mean response times (RTs), however, conflate the influence of the human operator and the automated aid on team performance and may mask changes in the operator's performance strategy under aided conditions. The present study used a measure of parallel processing efficiency, or workload capacity, derived from empirical RT distributions as a novel gauge of human-automation performance and automation dependence in a speeded task. Participants performed a speeded probabilistic decision task with and without the assistance of an automated aid. RT distributions were used to calculate two variants of a workload capacity measure, COR(t) and CAND(t). Capacity measures gave evidence that a diagnosis from the automated aid speeded human participants' responses, and that participants did not moderate their own decision times in anticipation of diagnoses from the aid. Workload capacity provides a sensitive and informative measure of human-automation performance and operators' automation dependence in speeded tasks. © 2016, Human Factors and Ergonomics Society.

  16. Mixing by turbulent buoyant jets in slender containers

    International Nuclear Information System (INIS)

    Voropayev, S.I.; Nath, C.; Fernando, H.J.S.

    2012-01-01

    A turbulent buoyant jet injected vertically into a slender cylinder containing a stratified fluid is investigated experimentally. The working fluid is water, and salt is used to change its density to obtain either a positively or negatively buoyant jet. The interest is the vertical density distribution in container and its dependence on time and other parameters. For each case (lighter or heavier jet) the experimental data could be collapsed into a ‘universal’ time dependent behavior, when properly non-dimensionalized. A theoretical model is advanced to explain the results. Possible applications include refilling of crude oil into U.S. strategic petroleum reserves caverns. -- Highlights: ► We addresses a critical issue on refill of Strategic Petroleum Reserves. ► We conduct experiments on negatively/positively buoyant turbulent jets in long cavern. ► Basing on results of experiments we developed theoretical model for refill operations.

  17. Effect of time of day on performance, hormonal and metabolic response during a 1000-M cycling time trial.

    Directory of Open Access Journals (Sweden)

    Alan Lins Fernandes

    Full Text Available The aim of this study was to determine the effect of time of day on performance, pacing, and hormonal and metabolic responses during a 1000-m cycling time-trial. Nine male, recreational cyclists visited the laboratory four times. During the 1st visit the participants performed an incremental test and during the 2nd visit they performed a 1000-m cycling familiarization trial. On the 3rd and 4th visits, the participants performed a 1000-m TT at either 8 am or 6 pm, in randomized, repeated-measures, crossover design. The time to complete the time trial was lower in the evening than in the morning (88.2±8.7 versus 94.7±10.9 s, respectively, p0.05, but the norepinephrine response to the exercise was increased in the morning (+46%, p0.05. Our findings suggest that performance was improved in the evening, and it was accompanied by an improved hormonal and metabolic milieu.

  18. Residential response to voluntary time-of-use electricity rates

    Energy Technology Data Exchange (ETDEWEB)

    Mostafa Baladi, S. [Laurits R. Christensen Associates, Inc. Ames, IA 50011-1070 (United States); Herriges, Joseph A. [Iowa State University, 280D Heady Hall, Department of Economics, Iowa State University, Ames, IA 50011-1070 (United States); Sweeney, Thomas J. [MidAmerican Energy, Des Moines, Iowa (United States)

    1998-09-01

    The response of residential households to voluntary Time-of-Use (TOU) electricity rates is estimated using data from a recent experiment at Midwest Power Systems of Iowa. The study`s design allows us to examine both the participation decision and the customer`s load pattern changes once the TOU rate structure was in effect. Substitution elasticities between on-peak and off-peak electricity usage are estimated and compared to those obtained in earlier mandatory programs, indicating whether program volunteers are more responsive to TOU pricing than the typical household. Attitudinal questionnaires allow us to examine the role of usage perceptions in program participation

  19. Limited information estimation of the diffusion-based item response theory model for responses and response times.

    Science.gov (United States)

    Ranger, Jochen; Kuhn, Jörg-Tobias; Szardenings, Carsten

    2016-05-01

    Psychological tests are usually analysed with item response models. Recently, some alternative measurement models have been proposed that were derived from cognitive process models developed in experimental psychology. These models consider the responses but also the response times of the test takers. Two such models are the Q-diffusion model and the D-diffusion model. Both models can be calibrated with the diffIRT package of the R statistical environment via marginal maximum likelihood (MML) estimation. In this manuscript, an alternative approach to model calibration is proposed. The approach is based on weighted least squares estimation and parallels the standard estimation approach in structural equation modelling. Estimates are determined by minimizing the discrepancy between the observed and the implied covariance matrix. The estimator is simple to implement, consistent, and asymptotically normally distributed. Least squares estimation also provides a test of model fit by comparing the observed and implied covariance matrix. The estimator and the test of model fit are evaluated in a simulation study. Although parameter recovery is good, the estimator is less efficient than the MML estimator. © 2016 The British Psychological Society.

  20. A Two Time-scale response of the Southern Ocean to the Ozone Hole: Regional Responses and Mechanisms

    Science.gov (United States)

    Gnanadesikan, A.; Seviour, W.; Waugh, D.; Pradal, M. A. S.

    2016-12-01

    The impact of changing ozone on the climate of the Southern Ocean is evaluated using an ensemble of coupled climate models. By imposing a step change from 1860 to 2000 conditions we are able to estimate response functions associated with this change. Two time scales are found, an initial cooling centered in the Southwest Pacific followed by cooling in the Pacific sector and then warming in both sectors. The physical processes that drive this response are different across time periods and locations, as is the sign of the response itself. Initial cooling in the Pacific sector is not just driven by the increased winds pushing cold water northward, but also by a decrease in surface salinity reducing wintertime mixing and increased ice and clouds reflecting more shortwave radiation back to space. The decrease in salinity is primarily driven by a southward shift of precipitation associated with a shifting storm track, coupled with decreased evaporation associated with colder surface temperatures. A subsurface increase in heat associated with this reduction in mixing then upwells along the Antarctic coast, producing a subsequent warming. Similar changes in convective activity occur in the Weddell Sea but are offset in time.

  1. Fast response time alcohol gas sensor using nanocrystalline F

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 36; Issue 4. Fast response time alcohol gas sensor using nanocrystalline F-doped SnO2 films derived via sol–gel method. Sarbani Basu Yeong-Her Wang C Ghanshyam Pawan Kapur. Volume 36 Issue 4 August 2013 pp 521-533 ...

  2. In-situ measurement of response time of RTDs and pressure transmitters in nuclear power plants

    International Nuclear Information System (INIS)

    Hashemian, H.M.; Riner, J.L.

    1993-01-01

    Response time measurements are performed once every fuel cycle on most safety-related temperature and pressure sensors in a majority of nuclear power plants in the US. This paper provides a review of the methods that are used for these measurements. The methods are referred to as the Loop Current Step Response (LCSR) test, which is used for response time testing of temperature sensors, and noise analysis and power interrupt (PI) tests, which are used for response time testing of pressure, level, and flow transmitters

  3. Computation Offloading for Frame-Based Real-Time Tasks under Given Server Response Time Guarantees

    Directory of Open Access Journals (Sweden)

    Anas S. M. Toma

    2014-11-01

    Full Text Available Computation offloading has been adopted to improve the performance of embedded systems by offloading the computation of some tasks, especially computation-intensive tasks, to servers or clouds. This paper explores computation offloading for real-time tasks in embedded systems, provided given response time guarantees from the servers, to decide which tasks should be offloaded to get the results in time. We consider frame-based real-time tasks with the same period and relative deadline. When the execution order of the tasks is given, the problem can be solved in linear time. However, when the execution order is not specified, we prove that the problem is NP-complete. We develop a pseudo-polynomial-time algorithm for deriving feasible schedules, if they exist.  An approximation scheme is also developed to trade the error made from the algorithm and the complexity. Our algorithms are extended to minimize the period/relative deadline of the tasks for performance maximization. The algorithms are evaluated with a case study for a surveillance system and synthesized benchmarks.

  4. Time response of fast-gated microchannel plates used as x-ray detectors

    International Nuclear Information System (INIS)

    Turner, R.E.; Bell, P.; Hanks, R.; Kilkenny, J.D.; Landen, N.; Power, G.; Wiedwald, J.; Meier, M.

    1990-01-01

    We report measurements of the time response of fast-gated, micro- channel plate (MCP) detectors, using a <10 ps pulsewidth ultra-violet laser and an electronic sampling system to measure time resolutions to better than 25 ps. The results show that framing times of less than 100 ps are attainable with high gain. The data is compared to a Monte Carlo calculation, which shows good agreement. We also measured the relative sensitivity as a function of DC bias, and saturation effects for large signal inputs. In part B, we briefly describe an electrical ''time-of-flight'' technique, which we have used to measure the response time of a fast-gated microchannel plate (MCP). Thinner MCP's than previously used have been tested, and, as expected, show fast gating times and smaller electron multiplication. A preliminary design for an x-ray pinhole camera, using a thin MCP, is presented. 7 refs., 6 figs

  5. Contracts for Cross-organizational Workflows as Timed Dynamic Condition Response Graphs

    DEFF Research Database (Denmark)

    Hildebrandt, Thomas; Mukkamala, Raghava Rao; Slaats, Tijs

    2013-01-01

    We conservatively extend the declarative Dynamic Condition Response (DCR) Graph process model, introduced in the PhD thesis of the second author, to allow for discrete time deadlines. We prove that safety and liveness properties can be verified by mapping finite timed DCR Graphs to finite state...

  6. Time orientation, planning horizons and responsibility into the future

    International Nuclear Information System (INIS)

    Svenson, O.; Nilsson, G.

    1988-01-01

    Subjects of four categories (social science students, engineering students, retired people and nuclear waste experts) were asked about past events, planning, risks and future time with emphasis on energy related issues and in particular questions concerning spent nuclear waste. Among, the results reported it was found that events in the past were located more or less correctly and that events further back systematically too close to the present. Today's responsibility into the future was judged to cover 3 to 6 generations ahead and an adequate planning horizon for a local community to be on the average 11 to 14 years. Adequate planning horizons for the handling of spent nuclear fuel were judged to be from 100 to 500 years. The responsibility for effects of today's decisions was judged to be from about 100 to 300 years into the future for environmental pollution and from about 50 to 600 years for nuclear waste. However, non-negliqable proportions of the subjects choose a more moral standpoint and gave answers indicating that responsibility had to be unlimited. Some sex differences were found and an interaction with age offered as a hypothesis to be investigated in the future. Interrelations between clusters of questions revealed some links from past time and planning to judgements of environmental and nuclear power related risks. (orig.)

  7. Delayed system response times affect immediate physiology and the dynamics of subsequent button press behavior.

    Science.gov (United States)

    Kohrs, Christin; Hrabal, David; Angenstein, Nicole; Brechmann, André

    2014-11-01

    System response time research is an important issue in human-computer interactions. Experience with technical devices and general rules of human-human interactions determine the user's expectation, and any delay in system response time may lead to immediate physiological, emotional, and behavioral consequences. We investigated such effects on a trial-by-trial basis during a human-computer interaction by measuring changes in skin conductance (SC), heart rate (HR), and the dynamics of button press responses. We found an increase in SC and a deceleration of HR for all three delayed system response times (0.5, 1, 2 s). Moreover, the data on button press dynamics was highly informative since subjects repeated a button press with more force in response to delayed system response times. Furthermore, the button press dynamics could distinguish between correct and incorrect decisions and may thus even be used to infer the uncertainty of a user's decision. Copyright © 2014 Society for Psychophysiological Research.

  8. The effect of loading time on flexible pavement dynamic response: a finite element analysis

    Science.gov (United States)

    Yin, Hao; Solaimanian, Mansour; Kumar, Tanmay; Stoffels, Shelley

    2007-12-01

    Dynamic response of asphalt concrete (AC) pavements under moving load is a key component for accurate prediction of flexible pavement performance. The time and temperature dependency of AC materials calls for utilizing advanced material characterization and mechanistic theories, such as viscoelasticity and stress/strain analysis. In layered elastic analysis, as implemented in the new Mechanistic-Empirical Pavement Design Guide (MEPDG), the time dependency is accounted for by calculating the loading times at different AC layer depths. In this study, the time effect on pavement response was evaluated by means of the concept of “pseudo temperature.” With the pavement temperature measured from instrumented thermocouples, the time and temperature dependency of AC materials was integrated into one single factor, termed “effective temperature.” Via this effective temperature, pavement responses under a transient load were predicted through finite element analysis. In the finite element model, viscoelastic behavior of AC materials was characterized through relaxation moduli, while the layers with unbound granular material were assumed to be in an elastic mode. The analysis was conducted for two different AC mixtures in a simplified flexible pavement structure at two different seasons. Finite element analysis results reveal that the loading time has a more pronounced impact on pavement response in the summer for both asphalt types. The results indicate that for reasonable prediction of dynamic response in flexible pavements, the effect of the depth-dependent loading time on pavement temperature should be considered.

  9. Broadband Structural Dynamics: Understanding the Impulse-Response of Structures Across Multiple Length and Time Scales

    Science.gov (United States)

    2010-08-18

    Spectral domain response calculated • Time domain response obtained through inverse transform Approach 4: WASABI Wavelet Analysis of Structural Anomalies...differences at unity scale! Time Function Transform Apply Spectral Domain Transfer Function Time Function Inverse Transform Transform Transform  mtP

  10. Desirable Strategic Petroleum Reserves policies in response to supply uncertainty: A stochastic analysis

    International Nuclear Information System (INIS)

    Bai, Yang; Zhou, Peng; Tian, Lixin; Meng, Fanyi

    2016-01-01

    Highlights: • A stochastic model is proposed to study Strategic Petroleum Reserves (SPR) policy. • The model aims to find desirable SPR size, acquisition, drawdown and refilling policy. • The impact of SPR policy and supply disruption on oil price has been examined. - Abstract: The paper proposes a survey on three issues related to Strategic Petroleum Reserves (SPR) policy. Firstly, what are the optimal SPR acquisition, drawdown and refilling policy in response to various market risks? Secondly, how SPR policy or actions will affect the market factors, i.e. oil demand or price. Thirdly, in what extend a disruption may induce price shock. For the purpose, the study proposed a Markov Decision Process model (SPR-MDP). In the model, oil supply, disruption size and duration are considered to be highly stochastic. Oil price is determined by market fundamentals exclusively. According to the empirical study, we come to some interesting conclusions. Firstly, oil price and disruption risk show different ways in influencing the desirable SPR size. It is found that the SPR size increases with the decrease of oil price while increase of disruption risk. Secondly, SPR acquisition may increase oil price slightly by influencing the basic fundamentals. In given case, we find acquisition of 7 million barrels per month increase the price by 2.6%. But the influence weakens with decrease of acquisition size. Thirdly, disruption duration shows significant impact on SPR drawdown policy. In a two-month disruption case, it is found that 51% of SPR should be released in the first month. Another 40% is released in the following month. The other 9% SPR is left for forthcoming disruptions. Meanwhile, SPR drawdown shows high efficient in damping oil price in the disruption. In given case, after drawdown of SPR, the oil prices only increases by 0.7% in the second month though continue disruption.

  11. Methodological challenges in assessment of current use of warfarin among patients with atrial fibrillation using dispensation data from administrative health care databases.

    Science.gov (United States)

    Sinyavskaya, Liliya; Matteau, Alexis; Johnson, Sarasa; Durand, Madeleine

    2018-06-05

    Algorithms to define current exposure to warfarin using administrative data may be imprecise. Study objectives were to characterize dispensation patterns, to measure gaps between expected and observed refill dates for warfarin and direct oral anticoagulants (DOACs). Retrospective cohort study using administrative health care databases of the Régie de l'assurance-maladie du Québec. We identified every dispensation of warfarin, dabigatran, rivaroxaban, or apixaban for patients with AF initiating oral anticoagulants between 2010 and 2015. For each dispensation, we extracted date and duration. Refill gaps were calculated as difference between expected and observed dates of successive dispensation. Refill gaps were summarized using descriptive statistics. To account for repeated observations nested within patients and to assess the components of variance of refill gaps, we used unconditional multilevel linear models. We identified 61 516 new users. Majority were prescribed warfarin (60.3%), followed by rivaroxaban (16.4%), dabigatran (14.5%), apixaban (8.8%). Most frequent recorded duration of dispensation was 7 days, suggesting use of pharmacist-prepared weekly pillboxes. The average refill gap from multilevel model was higher for warfarin (9.28 days, 95%CI:8.97-9.59) compared with DOACs (apixaban 3.08 days, 95%CI: 2.96-3.20, dabigatran 3.70, 95%CI: 3.56-3.84, rivaroxaban 3.15, 95%CI: 3.03-3.27). The variance of refill gaps was greater among warfarin users than among DOAC users. Greater refill gaps for warfarin may reflect inadequate capture of the period covered by the number of dispensed pills recorded in administrative data. A time-dependent definition of exposure using dispensation data would lead to greater misclassification of warfarin than DOACs use. Copyright © 2018 John Wiley & Sons, Ltd.

  12. Collecting response times using Amazon Mechanical Turk and Adobe Flash.

    Science.gov (United States)

    Simcox, Travis; Fiez, Julie A

    2014-03-01

    Crowdsourcing systems like Amazon's Mechanical Turk (AMT) allow data to be collected from a large sample of people in a short amount of time. This use has garnered considerable interest from behavioral scientists. So far, most experiments conducted on AMT have focused on survey-type instruments because of difficulties inherent in running many experimental paradigms over the Internet. This study investigated the viability of presenting stimuli and collecting response times using Adobe Flash to run ActionScript 3 code in conjunction with AMT. First, the timing properties of Adobe Flash were investigated using a phototransistor and two desktop computers running under several conditions mimicking those that may be present in research using AMT. This experiment revealed some strengths and weaknesses of the timing capabilities of this method. Next, a flanker task and a lexical decision task implemented in Adobe Flash were administered to participants recruited with AMT. The expected effects in these tasks were replicated. Power analyses were conducted to describe the number of participants needed to replicate these effects. A questionnaire was used to investigate previously undescribed computer use habits of 100 participants on AMT. We conclude that a Flash program in conjunction with AMT can be successfully used for running many experimental paradigms that rely on response times, although experimenters must understand the limitations of the method.

  13. Analytical solution for beam with time-dependent boundary conditions versus response spectrum

    International Nuclear Information System (INIS)

    Gou, P.F.; Panahi, K.K.

    2001-01-01

    This paper studies the responses of a uniform simple beam for which the supports are subjected to time-dependent conditions. Analytical solution in terms of series was presented for two cases: (1) Two supports of a simple beam are subjected to a harmonic motion, and (2) One of the two supports is stationary while the other is subjected to a harmonic motion. The results of the analytical solution were investigated and compared with the results of conventional response spectrum method using the beam finite element model. One of the applications of the results presented in this paper can be used to assess the adequacy and accuracy of the engineering approaches such as response spectra methods. It has been found that, when the excitation frequency equals the fundamental frequency of the beam, the results from response spectrum method are in good agreement with the exact calculation. The effects of initial conditions on the responses are also examined. It seems that the non-zero initial velocity has pronounced effects on the displacement time histories but it has no effect on the maximum accelerations. (author)

  14. Equivalence between short-time biphasic and incompressible elastic material responses.

    Science.gov (United States)

    Ateshian, Gerard A; Ellis, Benjamin J; Weiss, Jeffrey A

    2007-06-01

    Porous-permeable tissues have often been modeled using porous media theories such as the biphasic theory. This study examines the equivalence of the short-time biphasic and incompressible elastic responses for arbitrary deformations and constitutive relations from first principles. This equivalence is illustrated in problems of unconfined compression of a disk, and of articular contact under finite deformation, using two different constitutive relations for the solid matrix of cartilage, one of which accounts for the large disparity observed between the tensile and compressive moduli in this tissue. Demonstrating this equivalence under general conditions provides a rationale for using available finite element codes for incompressible elastic materials as a practical substitute for biphasic analyses, so long as only the short-time biphasic response is sought. In practice, an incompressible elastic analysis is representative of a biphasic analysis over the short-term response deltatelasticity tensor, and K is the hydraulic permeability tensor of the solid matrix. Certain notes of caution are provided with regard to implementation issues, particularly when finite element formulations of incompressible elasticity employ an uncoupled strain energy function consisting of additive deviatoric and volumetric components.

  15. Generation of artificial time-histories, rich in all frequencies, from given response spectra

    International Nuclear Information System (INIS)

    Levy, S.; Wilkinson, J.P.D.

    1975-01-01

    In order to apply the time-history method of seismic analysis, it is often desirable to generate a suitable artificial time-history from a given response spectrum. The method described allows the generation of such a time-history that is also rich in all frequencies in the spectrum. This richness is achieved by choosing a large number of closely-spaced frequency points such that the adjacent frequencies have their half-power points overlap. The adjacent frequencies satisfy the condition that the frequency interval Δf near a given frequency f is such that (Δf)/f<2c/csub(c) where c is the damping of the system and csub(c) is the critical damping. In developing an artificial time-history, it is desirable to specify the envelope and duration of the record, very often in such a manner as to reproduce the envelope property of a specific earthquake record, and such an option is available in the method described. Examples are given of the development of typical artificial time-histories from earthquake design response spectra and from floor response spectra

  16. Time response measurements of Rosemount Pressure Transmitters (model 3154) of Angra-1 power plant

    International Nuclear Information System (INIS)

    Santos, Roberto Carlos dos; Pereira, Iraci Martinez; Justino, Marcelo C.; Silva, Marcos C.

    2017-01-01

    This paper shows the Response of time five Rosemount model 3154N pressure transmitter from the Angra I Nuclear Power Plant. The tests were performed using the Hydraulic Ramp and Pressure Step Generator from the Sensor Response Time Measurement laboratory of CEN - Nuclear Engineering Center of IPEN. For each transmitter, damping was adjusted so that the time constant was less than or equal to 500 ms. This value has been determined so that the total value of the protection chain response time does not exceed the established maximum value of 2 seconds. For each transmitter ten tests were performed, obtaining mean values of time constant of 499.7 ms, 464.1 ms, 473.8 ms, 484.7 ms and 511.5 ms, with mean deviations 0.85%, 0.24%, 0.97%, 1.26% and 0.64% respectively. (author)

  17. Time response measurements of Rosemount Pressure Transmitters (model 3154) of Angra-1 power plant

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Roberto Carlos dos; Pereira, Iraci Martinez [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Justino, Marcelo C.; Silva, Marcos C., E-mail: rcsantos@ipen.br, E-mail: justino@eletronuclear.gov.br [Eletrobrás Termonuclear S.A. (ELETRONUCLEAR), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    This paper shows the Response of time five Rosemount model 3154N pressure transmitter from the Angra I Nuclear Power Plant. The tests were performed using the Hydraulic Ramp and Pressure Step Generator from the Sensor Response Time Measurement laboratory of CEN - Nuclear Engineering Center of IPEN. For each transmitter, damping was adjusted so that the time constant was less than or equal to 500 ms. This value has been determined so that the total value of the protection chain response time does not exceed the established maximum value of 2 seconds. For each transmitter ten tests were performed, obtaining mean values of time constant of 499.7 ms, 464.1 ms, 473.8 ms, 484.7 ms and 511.5 ms, with mean deviations 0.85%, 0.24%, 0.97%, 1.26% and 0.64% respectively. (author)

  18. Time to response to citalopram treatment for agitation in Alzheimer's disease

    Science.gov (United States)

    Weintraub, Daniel; Drye, Lea T.; Porsteinsson, Anton P.; Rosenberg, Paul B.; Pollock, Bruce G.; Devanand, D.P.; Frangakis, Constantine; Ismail, Zahinoor; Marano, Christopher; Meinert, Curtis L.; Mintzer, Jacobo E.; Munro, Cynthia A.; Pelton, Gregory; Rabins, Peter V.; Schneider, Lon S.; Shade, David M.; Yesavage, Jerome; Lyketsos, Constantine G.

    2015-01-01

    Background Agitation is a common and significant problem in Alzheimer’s disease (AD). In the recent Citalopram for Agitation in Alzheimer’s Disease (CitAD) study, citalopram was efficacious for the treatment of AD agitation. Here we examined the time course and predictors of response to treatment. Methods Response in CitAD was defined as a modified Alzheimer Disease Cooperative Study-Clinical Global Impression of Change (mADCS-CGIC) score of 1 or 2, or a Neurobehavioral Rating Scale agitation subscale (NBRS-A) score reduction ≥50% from baseline. “Stable early response” was defined as meeting the aforementioned criteria at both weeks 3 and 9, “late response” was response at week 9 but not at week 3, and “unstable response” was response at week 3 but not at week 9. Results In the primary analyses, citalopram was superior to placebo on both the CGIC and the NBRS-A response measures. There were little between-group differences in response rates in the first three weeks of the study (21% vs 19% on the CGIC). Citalopram patients were more likely than placebo patients to be a late responder (18% vs. 8% on CGIC, Fisher’s exact p=0.09; 31% vs. 15% on NBRS-A, Fisher’s exact p=0.02). Approximately half (45–56%) of citalopram responders at end-of-study achieved response later in the study, compared with 30–44% of placebo responders. Discussion Treatment with citalopram for agitation in AD needs to be at least nine weeks in duration to allow sufficient time for full response, and study duration is an important factor to consider in the design of clinical trials for agitation in Alzheimer’s disease. PMID:26238225

  19. Time delay and duration of ionospheric total electron content responses to geomagnetic disturbances

    Directory of Open Access Journals (Sweden)

    J. Liu

    2010-03-01

    Full Text Available Although positive and negative signatures of ionospheric storms have been reported many times, global characteristics such as the time of occurrence, time delay and duration as well as their relations to the intensity of the ionospheric storms have not received enough attention. The 10 years of global ionosphere maps (GIMs of total electron content (TEC retrieved at Jet Propulsion Laboratory (JPL were used to conduct a statistical study of the time delay of the ionospheric responses to geomagnetic disturbances. Our results show that the time delays between geomagnetic disturbances and TEC responses depend on season, magnetic local time and magnetic latitude. In the summer hemisphere at mid- and high latitudes, the negative storm effects can propagate to the low latitudes at post-midnight to the morning sector with a time delay of 4–7 h. As the earth rotates to the sunlight, negative phase retreats to higher latitudes and starts to extend to the lower latitude toward midnight sector. In the winter hemisphere during the daytime and after sunset at mid- and low latitudes, the negative phase appearance time is delayed from 1–10 h depending on the local time, latitude and storm intensity compared to the same area in the summer hemisphere. The quick response of positive phase can be observed at the auroral area in the night-side of the winter hemisphere. At the low latitudes during the dawn-noon sector, the ionospheric negative phase responses quickly with time delays of 5–7 h in both equinoctial and solsticial months.

    Our results also manifest that there is a positive correlation between the intensity of geomagnetic disturbances and the time duration of both the positive phase and negative phase. The durations of both negative phase and positive phase have clear latitudinal, seasonal and magnetic local time (MLT dependence. In the winter hemisphere, long durations for the positive phase are 8–11 h and 12–14 h during the daytime at

  20. Time delay and duration of ionospheric total electron content responses to geomagnetic disturbances

    Directory of Open Access Journals (Sweden)

    J. Liu

    2010-03-01

    Full Text Available Although positive and negative signatures of ionospheric storms have been reported many times, global characteristics such as the time of occurrence, time delay and duration as well as their relations to the intensity of the ionospheric storms have not received enough attention. The 10 years of global ionosphere maps (GIMs of total electron content (TEC retrieved at Jet Propulsion Laboratory (JPL were used to conduct a statistical study of the time delay of the ionospheric responses to geomagnetic disturbances. Our results show that the time delays between geomagnetic disturbances and TEC responses depend on season, magnetic local time and magnetic latitude. In the summer hemisphere at mid- and high latitudes, the negative storm effects can propagate to the low latitudes at post-midnight to the morning sector with a time delay of 4–7 h. As the earth rotates to the sunlight, negative phase retreats to higher latitudes and starts to extend to the lower latitude toward midnight sector. In the winter hemisphere during the daytime and after sunset at mid- and low latitudes, the negative phase appearance time is delayed from 1–10 h depending on the local time, latitude and storm intensity compared to the same area in the summer hemisphere. The quick response of positive phase can be observed at the auroral area in the night-side of the winter hemisphere. At the low latitudes during the dawn-noon sector, the ionospheric negative phase responses quickly with time delays of 5–7 h in both equinoctial and solsticial months. Our results also manifest that there is a positive correlation between the intensity of geomagnetic disturbances and the time duration of both the positive phase and negative phase. The durations of both negative phase and positive phase have clear latitudinal, seasonal and magnetic local time (MLT dependence. In the winter hemisphere, long durations for the positive phase are 8–11 h and 12–14 h during the daytime at middle

  1. Myosin-II sets the optimal response time scale of chemotactic amoeba

    Science.gov (United States)

    Hsu, Hsin-Fang; Westendorf, Christian; Tarantola, Marco; Bodenschatz, Eberhard; Beta, Carsten

    2014-03-01

    The response dynamics of the actin cytoskeleton to external chemical stimuli plays a fundamental role in numerous cellular functions. One of the key players that governs the dynamics of the actin network is the motor protein myosin-II. Here we investigate the role of myosin-II in the response of the actin system to external stimuli. We used a microfluidic device in combination with a photoactivatable chemoattractant to apply stimuli to individual cells with high temporal resolution. We directly compare the actin dynamics in Dictyostelium discodelium wild type (WT) cells to a knockout mutant that is deficient in myosin-II (MNL). Similar to the WT a small population of MNL cells showed self-sustained oscillations even in absence of external stimuli. The actin response of MNL cells to a short pulse of chemoattractant resembles WT during the first 15 sec but is significantly delayed afterward. The amplitude of the dominant peak in the power spectrum from the response time series of MNL cells to periodic stimuli with varying period showed a clear resonance peak at a forcing period of 36 sec, which is significantly delayed as compared to the resonance at 20 sec found for the WT. This shift indicates an important role of myosin-II in setting the response time scale of motile amoeba. Institute of Physics und Astronomy, University of Potsdam, Karl-Liebknecht-Str. 24/25, 14476 Potsdam, Germany.

  2. Time-of-use based electricity demand response for sustainable manufacturing systems

    International Nuclear Information System (INIS)

    Wang, Yong; Li, Lin

    2013-01-01

    As required by the Energy Policy Act of 2005, utility companies across the U.S. are offering TOU (time-of-use) based electricity demand response programs. The TOU rate gives consumers opportunities to manage their electricity bill by shifting use from on-peak periods to mid-peak and off-peak periods. Reducing the amount of electricity needed during the peak load times makes it possible for the power grid to meet consumers' needs without building more costly backup infrastructures and help reduce GHG (greenhouse gas) emissions. Previous research on the applications of TOU and other electricity demand response programs has been mainly focused on residential and commercial buildings while largely neglected industrial manufacturing systems. This paper proposes a systems approach for TOU based electricity demand response for sustainable manufacturing systems under the production target constraint. Key features of this approach include: (i) the electricity related costs including both consumption and demand are integrated into production system modeling; (ii) energy-efficient and demand-responsive production scheduling problems are formulated and the solution technique is provided; and (iii) the effects of various factors on the near-optimal scheduling solutions are examined. The research outcome is expected to enhance the energy efficiency, electricity demand responsiveness, and cost effectiveness of modern manufacturing systems. - Highlights: • We propose a TOU based demand response approach for manufacturing systems. • Both electricity consumption and demand are integrated into the system modeling. • Energy-efficient and demand-responsive production scheduling problems are formulated. • The meta-heuristic solution technique is provided. • The effects of various factors on the scheduling solutions are examined

  3. A Simple Network Architecture Accounts for Diverse Reward Time Responses in Primary Visual Cortex.

    Science.gov (United States)

    Huertas, Marco A; Hussain Shuler, Marshall G; Shouval, Harel Z

    2015-09-16

    Many actions performed by animals and humans depend on an ability to learn, estimate, and produce temporal intervals of behavioral relevance. Exemplifying such learning of cued expectancies is the observation of reward-timing activity in the primary visual cortex (V1) of rodents, wherein neural responses to visual cues come to predict the time of future reward as behaviorally experienced in the past. These reward-timing responses exhibit significant heterogeneity in at least three qualitatively distinct classes: sustained increase or sustained decrease in firing rate until the time of expected reward, and a class of cells that reach a peak in firing at the expected delay. We elaborate upon our existing model by including inhibitory and excitatory units while imposing simple connectivity rules to demonstrate what role these inhibitory elements and the simple architectures play in sculpting the response dynamics of the network. We find that simply adding inhibition is not sufficient for obtaining the different distinct response classes, and that a broad distribution of inhibitory projections is necessary for obtaining peak-type responses. Furthermore, although changes in connection strength that modulate the effects of inhibition onto excitatory units have a strong impact on the firing rate profile of these peaked responses, the network exhibits robustness in its overall ability to predict the expected time of reward. Finally, we demonstrate how the magnitude of expected reward can be encoded at the expected delay in the network and how peaked responses express this reward expectancy. Heterogeneity in single-neuron responses is a common feature of neuronal systems, although sometimes, in theoretical approaches, it is treated as a nuisance and seldom considered as conveying a different aspect of a signal. In this study, we focus on the heterogeneous responses in the primary visual cortex of rodents trained with a predictable delayed reward time. We describe under what

  4. Charge distribution and response time for a modulation-doped extrinsic infrared detector

    Science.gov (United States)

    Hadek, Victor

    1987-01-01

    The electric charge distribution and response time of a modulation-doped extrinsic infrared detector are determined. First, it is demonstrated theoretically that the photoconductive layer is effectively depleted of ionized majority-impurity charges so that scattering is small and mobility is high for photogenerated carriers. Then, using parameters appropriate to an actual detector, the predicted response time is 10 to the -8th to about 10 to the -9th s, which is much faster than comparable conventional detectors. Thus, the modulation-doped detector design would be valuable for heterodyne applications.

  5. Presentation and response timing accuracy in Adobe Flash and HTML5/JavaScript Web experiments.

    Science.gov (United States)

    Reimers, Stian; Stewart, Neil

    2015-06-01

    Web-based research is becoming ubiquitous in the behavioral sciences, facilitated by convenient, readily available participant pools and relatively straightforward ways of running experiments: most recently, through the development of the HTML5 standard. Although in most studies participants give untimed responses, there is a growing interest in being able to record response times online. Existing data on the accuracy and cross-machine variability of online timing measures are limited, and generally they have compared behavioral data gathered on the Web with similar data gathered in the lab. For this article, we took a more direct approach, examining two ways of running experiments online-Adobe Flash and HTML5 with CSS3 and JavaScript-across 19 different computer systems. We used specialist hardware to measure stimulus display durations and to generate precise response times to visual stimuli in order to assess measurement accuracy, examining effects of duration, browser, and system-to-system variability (such as across different Windows versions), as well as effects of processing power and graphics capability. We found that (a) Flash and JavaScript's presentation and response time measurement accuracy are similar; (b) within-system variability is generally small, even in low-powered machines under high load; (c) the variability of measured response times across systems is somewhat larger; and (d) browser type and system hardware appear to have relatively small effects on measured response times. Modeling of the effects of this technical variability suggests that for most within- and between-subjects experiments, Flash and JavaScript can both be used to accurately detect differences in response times across conditions. Concerns are, however, noted about using some correlational or longitudinal designs online.

  6. Bedside detection of low systemic flow in the very low birth weight infant on day 1 of life.

    LENUS (Irish Health Repository)

    Miletin, J

    2012-02-01

    We aimed to assess the relationship between the clinical and biochemical parameters of perfusion and superior vena cava (SVC) flow in a prospective observational cohort study of very low birth weight (VLBW) infants. Newborns with congenital heart disease were excluded. Echocardiographic evaluation of SVC flow was performed in the first 24 h of life. Capillary refill time (forehead, sternum and toe), mean blood pressure, urine output and serum lactate concentration were also measured simultaneously. Thirty-eight VLBW infants were examined. Eight patients (21%) had SVC flow less than 40 ml\\/kg\\/min. There was a poor correlation between the capillary refill time (in all sites), mean blood pressure, urine output and SVC flow. The correlation coefficient for the serum lactate concentration was r = -0.28, p = 0.15. The median serum lactate concentration was 3.5 (range 2.8-8.5) vs. 2.7 (range 1.2-6.9) mmol\\/l (p = 0.01) in low flow versus normal flow states. A serum lactate concentration of >2.8 was 100% sensitive and 60% specific for detecting a low flow state. Combining a capillary refill time of >4 s with a serum lactate concentration of >4 mmol\\/l had a specificity of 97% for detecting a low SVC flow state. Serum lactate concentrations are higher in low SVC flow states. A capillary refill time of >4 s combined with serum lactate concentrations >4 mmol\\/l increased the specificity and positive and negative predictive values of detecting a low SVC flow state.

  7. Time-dependent nonequilibrium soft x-ray response during a spin crossover

    Science.gov (United States)

    van Veenendaal, Michel

    2018-03-01

    A theoretical framework is developed for better understanding the time-dependent soft-x-ray response of dissipative quantum many-body systems. It is shown how x-ray absorption and resonant inelastic x-ray scattering (RIXS) at transition-metal L edges can provide insight into ultrafast intersystem crossings of importance for energy conversion, ultrafast magnetism, and catalysis. The photoinduced doublet-to-quartet spin crossover on cobalt in Fe-Co Prussian blue analogs is used as a model system to demonstrate how the x-ray response is affected by the nonequilibrium dynamics on a femtosecond time scale. Changes in local spin and symmetry and the underlying mechanism are reflected in strong broadenings, a collapse of clear selection rules during the intersystem crossing, fluctuations in the isotropic branching ratio in x-ray absorption, crystal-field collapse and/or oscillations, and time-dependent anti-Stokes processes in RIXS.

  8. On-line measurements of response time of temperature and pressure sensors in PWRs

    International Nuclear Information System (INIS)

    Hashemian, H.M.

    2004-01-01

    A review of modern techniques for in-situ response time testing of resistance temperature detectors (RTDs), and pressure, level and flow transmitters is presented. These techniques have been developed and validated for use in pressurized and boiling water reactors. The significance of the modern techniques is that they permit testing of installed sensors at process operating conditions and thereby provide the actual in-service response times of the sensors. (author)

  9. Time-dependent nonequilibrium soft x-ray response during a spin crossover

    Energy Technology Data Exchange (ETDEWEB)

    van Veenendaal, Michel

    2018-03-01

    The rapid development of high-brilliance pulsed X-ray sources with femtosecond time resolution has created a need for a better theoretical understanding of the time-dependent soft-X-ray response of dissipative many-body quantum systems. It is demonstrated how soft-X-ray spectroscopies, such as X-ray absorption and resonant inelastic X-ray scattering at transition-metal L-edges, can provide insight into intersystem crossings, such as a spin crossover. The photoinduced doublet-to-quartet spin crossover on cobalt in Fe-Co Prussian blue analogues is used as an example to demonstrate how the X-ray response is affected by the dissipative nonequilibrium dynamics. The time-dependent soft-X-ray spectra provide a wealth of information that reflect the changes in the nonequilibrium initial state via continuously changing spectral lineshapes that cannot be decomposed into initial photoexcited and final metastable spectra, strong broadenings, a collapse of clear selection rules during the intersystem crossing, strong fluctuations in the isotropic branching ratio in X-ray absorption, and crystal-field collapse/oscillations and strongly time-dependent anti-Stokes processes in RIXS.

  10. Comparing Response Times and Error Rates in a Simultaneous Masking Paradigm

    Directory of Open Access Journals (Sweden)

    F Hermens

    2014-08-01

    Full Text Available In simultaneous masking, performance on a foveally presented target is impaired by one or more flanking elements. Previous studies have demonstrated strong effects of the grouping of the target and the flankers on the strength of masking (e.g., Malania, Herzog & Westheimer, 2007. These studies have predominantly examined performance by measuring offset discrimination thresholds as a measure of performance, and it is therefore unclear whether other measures of performance provide similar outcomes. A recent study, which examined the role of grouping on error rates and response times in a speeded vernier offset discrimination task, similar to that used by Malania et al. (2007, suggested a possible dissociation between the two measures, with error rates mimicking threshold performance, but response times showing differential results (Panis & Hermens, 2014. We here report the outcomes of three experiments examining this possible dissociation, and demonstrate an overall similar pattern of results for error rates and response times across a broad range of mask layouts. Moreover, the pattern of results in our experiments strongly correlates with threshold performance reported earlier (Malania et al., 2007. Our results suggest that outcomes in a simultaneous masking paradigm do not critically depend on the outcome measure used, and therefore provide evidence for a common underlying mechanism.

  11. Time Domains of the Hypoxic Ventilatory Response and Their Molecular Basis

    Science.gov (United States)

    Pamenter, Matthew E.; Powell, Frank L.

    2016-01-01

    Ventilatory responses to hypoxia vary widely depending on the pattern and length of hypoxic exposure. Acute, prolonged, or intermittent hypoxic episodes can increase or decrease breathing for seconds to years, both during the hypoxic stimulus, and also after its removal. These myriad effects are the result of a complicated web of molecular interactions that underlie plasticity in the respiratory control reflex circuits and ultimately control the physiology of breathing in hypoxia. Since the time domains of the physiological hypoxic ventilatory response (HVR) were identified, considerable research effort has gone toward elucidating the underlying molecular mechanisms that mediate these varied responses. This research has begun to describe complicated and plastic interactions in the relay circuits between the peripheral chemoreceptors and the ventilatory control circuits within the central nervous system. Intriguingly, many of these molecular pathways seem to share key components between the different time domains, suggesting that varied physiological HVRs are the result of specific modifications to overlapping pathways. This review highlights what has been discovered regarding the cell and molecular level control of the time domains of the HVR, and highlights key areas where further research is required. Understanding the molecular control of ventilation in hypoxia has important implications for basic physiology and is emerging as an important component of several clinical fields. PMID:27347896

  12. Time-frequency analysis of railway bridge response in forced vibration

    Science.gov (United States)

    Cantero, Daniel; Ülker-Kaustell, Mahir; Karoumi, Raid

    2016-08-01

    This paper suggests the use of the Continuous Wavelet Transform in combination with the Modified Littlewood-Paley basis to analyse bridge responses exited by traversing trains. The analysis provides an energy distribution map in the time-frequency domain that offers a better resolution compared to previous published studies. This is demonstrated with recorded responses of the Skidträsk Bridge, a 36 m long composite bridge located in Sweden. It is shown to be particularly useful to understand the evolution of the energy content during a vehicle crossing event. With this information it is possible to distinguish the effect of several of the governing factors involved in the dynamic response including vehicle's speed and axle configuration as well as non-linear behaviour of the structure.

  13. The BCD of response time analysis in experimental economics.

    Science.gov (United States)

    Spiliopoulos, Leonidas; Ortmann, Andreas

    2018-01-01

    For decisions in the wild, time is of the essence. Available decision time is often cut short through natural or artificial constraints, or is impinged upon by the opportunity cost of time. Experimental economists have only recently begun to conduct experiments with time constraints and to analyze response time (RT) data, in contrast to experimental psychologists. RT analysis has proven valuable for the identification of individual and strategic decision processes including identification of social preferences in the latter case, model comparison/selection, and the investigation of heuristics that combine speed and performance by exploiting environmental regularities. Here we focus on the benefits, challenges, and desiderata of RT analysis in strategic decision making. We argue that unlocking the potential of RT analysis requires the adoption of process-based models instead of outcome-based models, and discuss how RT in the wild can be captured by time-constrained experiments in the lab. We conclude that RT analysis holds considerable potential for experimental economics, deserves greater attention as a methodological tool, and promises important insights on strategic decision making in naturally occurring environments.

  14. Nonlinear Dielectric Response of Water Treed XLPE Cable Insulation

    Energy Technology Data Exchange (ETDEWEB)

    Hvidsten, Sverre

    1999-07-01

    frequency domain dielectric response was larger, and found to be more nonlinear than values measured in time domain. This thesis describes a new mechanism for the nonlinear dielectric response. It is assumed that at low or no applied electric stress the water treed region is characterised by spherical micro voids filled with liquid water separated by channels of crazed insulation. The effect of increasing the test voltage is to cause Maxwell mechanical tensile stresses strong enough to open up the crazing zones and elongate the water droplets into the mechanically weak crazing zones. Finite Element Method (FEM) calculations show that the effect of the re-opening of crazing zones by an increased test voltage, strongly increases the dielectric loss of the water treed insulation. This is qualitatively in good agreement with the experimental results obtained on water treed insulation, where increasing the test voltage above a certain value caused the losses to increase. The typical frequency independent dielectric response of water treed insulation can, however, not be explained by this model. Numerical calculations of losses, indicated that the mechanism of voltage assisted ingress of water is more likely in treed regions with rather low contents of water. The micro-FTIR measurements of single vented water trees indicated that such regions were likely to be present 3-400 (my)m within the tree tip, and close to the insulation screen. The process of refilling water into water tree structures is likely to be associated with a hysteresis effect. When removing (or reducing) the electric field, mechanical relaxation causes the channel to collapse and to slowly recover its former structure. Dielectric response measurements showed that a hysteresis was typically present when the response was nonlinear.

  15. Brain activations related to saccadic response conflict are not sensitive to time on task

    Directory of Open Access Journals (Sweden)

    Ewa eBeldzik

    2015-12-01

    Full Text Available Establishing a role of the dorsal medial frontal cortex in the performance monitoring and cognitive control has been a challenge to neuroscientists for the past decade. In light of recent findings, the conflict monitoring hypothesis has been elaborated to an action-outcome predictor theory. One of the findings that led to this re-evaluation was the fMRI study in which conflict-related brain activity was investigated in terms of the so-called time on task effect, i.e. a linear increase of the BOLD signal with longer response times. The aim of this study was to investigate brain regions involved in the processing of saccadic response conflict and to account for the time on task effect. A modified spatial cueing task was implemented in the event-related fMRI study with oculomotor responses. The results revealed several brain regions which show higher activity for incongruent trials in comparison to the congruent ones, including pre-supplementary motor area together with the frontal and parietal regions. Further analysis accounting for the effect of response time provided evidence that these brain activations were not sensitive to time on task but reflected purely the congruency effect.

  16. Brain Activations Related to Saccadic Response Conflict are not Sensitive to Time on Task.

    Science.gov (United States)

    Beldzik, Ewa; Domagalik, Aleksandra; Oginska, Halszka; Marek, Tadeusz; Fafrowicz, Magdalena

    2015-01-01

    Establishing a role of the dorsal medial frontal cortex in the performance monitoring and cognitive control has been a challenge to neuroscientists for the past decade. In light of recent findings, the conflict monitoring hypothesis has been elaborated to an action-outcome predictor theory. One of the findings that led to this re-evaluation was the fMRI study in which conflict-related brain activity was investigated in terms of the so-called time on task effect, i.e., a linear increase of the BOLD signal with longer response times. The aim of this study was to investigate brain regions involved in the processing of saccadic response conflict and to account for the time on task effect. A modified spatial cueing task was implemented in the event-related fMRI study with oculomotor responses. The results revealed several brain regions which show higher activity for incongruent trials in comparison to the congruent ones, including pre-supplementary motor area together with the frontal and parietal regions. Further analysis accounting for the effect of response time provided evidence that these brain activations were not sensitive to time on task but reflected purely the congruency effect.

  17. Time course of air hunger mirrors the biphasic ventilatory response to hypoxia.

    Science.gov (United States)

    Moosavi, S H; Banzett, R B; Butler, J P

    2004-12-01

    Determining response dynamics of hypoxic air hunger may provide information of use in clinical practice and will improve understanding of basic dyspnea mechanisms. It is hypothesized that air hunger arises from projection of reflex brain stem ventilatory drive ("corollary discharge") to forebrain centers. If perceptual response dynamics are unmodified by events between brain stem and cortical awareness, this hypothesis predicts that air hunger will exactly track ventilatory response. Thus, during sustained hypoxia, initial increase in air hunger would be followed by a progressive decline reflecting biphasic reflex ventilatory drive. To test this prediction, we applied a sharp-onset 20-min step of normocapnic hypoxia and compared dynamic response characteristics of air hunger with that of ventilation in 10 healthy subjects. Air hunger was measured during mechanical ventilation (minute ventilation = 9 +/- 1.4 l/min; end-tidal Pco(2) = 37 +/- 2 Torr; end-tidal Po(2) = 45 +/- 7 Torr); ventilatory response was measured during separate free-breathing trials in the same subjects. Discomfort caused by "urge to breathe" was rated every 30 s on a visual analog scale. Both ventilatory and air hunger responses were modeled as delayed double exponentials corresponding to a simple linear first-order response but with a separate first-order adaptation. These models provided adequate fits to both ventilatory and air hunger data (r(2) = 0.88 and 0.66). Mean time constant and time-to-peak response for the average perceptual response (0.36 min(-1) and 3.3 min, respectively) closely matched corresponding values for the average ventilatory response (0.39 min(-1) and 3.1 min). Air hunger response to sustained hypoxia tracked ventilatory drive with a delay of approximately 30 s. Our data provide further support for the corollary discharge hypothesis for air hunger.

  18. Make Time to Recharge: Growth and Renewal Play Key Roles in Sustaining School Leaders

    Science.gov (United States)

    Drago-Severson, Ellie; Blum-DeStefano, Jessica

    2015-01-01

    Being a school leader in any role is hard, gratifying, and a gift of love. While it can be enormously satisfying to serve students, teachers, families, and school communities, leaders need to refill themselves in order to continue giving to others. This article highlights a learning-oriented model of leadership development and capacity building…

  19. Generation of artificial time-histories, rich in all frequencies from given response spectra

    International Nuclear Information System (INIS)

    Levy, S.; Wilkinson, J.P.D.

    1975-01-01

    In order to apply the time-history method of seismic analysis, it is often desirable to generate a suitable artificial time-history from a given response spectrum. The method described in this paper allows the generation of such a time-history that is also rich in all frequencies in the spectrum. This richness is achieved by choosing a large number of closely-spaced frequency points such that the adjacent frequencies have their half-power points overlap. The adjacent frequencies satisfy the condition that the frequency interval Δf near a given frequency f is such that (Δf)/f<2c/csub(c) where c is the damping of the system and csub(c) is the critical damping. In developing an artificial time-history, it is desirable to specify the envelope and duration of the record, very often in such a manner as to reproduce the envelope property of a specific earthquake record, and such an option is available in the method described. Examples are given of the development of typical articifial time-histories from earthquake design response spectra and from floor response spectra. (Auth.)

  20. A Study of Time Response for Safety-Related Operator Actions in Non-LOCA Safety Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Seok; Lee, Sang Seob; Park, Min Soo; Lee, Gyu Cheon; Kim, Shin Whan [KEPCO E and C Company, Daejeon (Korea, Republic of)

    2014-10-15

    The classification of initiating events for safety analysis report (SAR) chapter 15 is categorized into moderate frequency events (MF), infrequent events (IF), and limiting faults (LF) depending on the frequency of its occurrence. For the non-LOCA safety analysis with the purpose to get construction or operation license, however, it is assumed that the operator response action to mitigate the events starts at 30 minutes after the initiation of the transient regardless of the event categorization. Such an assumption of corresponding operator response time may have over conservatism with the MF and IF events and results in a decrease in the safety margin compared to its acceptance criteria. In this paper, the plant conditions (PC) are categorized with the definitions in SAR 15 and ANS 51.1. Then, the consequence of response for safety-related operator action time is determined based on the PC in ANSI 58.8. The operator response time for safety analysis regarding PC are reviewed and suggested. The clarifying alarm response procedure would be required for the guideline to reduce the operator response time when the alarms indicate the occurrence of the transient.

  1. Sensitivity and response time improvements in millimeter-wave spectrometers

    International Nuclear Information System (INIS)

    Kolbe, W.F.; Leskovar, B.

    1980-09-01

    A new version of a microwave spectrometer for the detection of gaseous pollutants and other atmospheric constituents is described. The spectrometer, which operates in the vicinity of 70 GHz, employs a Fabry-Perot resonator as a sample cell and uses superhetrodyne detection for high sensitivity. The spectrometer has been modified to incorporate a frequency doubler modulated at 30 MHz to permit operation with a single Gunn oscillator source. As a result, faster response time and somewhat greater sensitivity are obtained. The spectrometer is capable of detecting a minimum concentration of 1 ppM of SO 2 diluted in air with a 1 second time constant. For OCS diluted in air, the minimum detectable concentration is 800 ppB and with a 10 second time constant 300 ppB

  2. New method for evaluating effective recovery time and single photoelectron response in silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Grodzicka, Martyna, E-mail: m.grodzicka@ncbj.gov.pl; Szczęśniak, Tomasz; Moszyński, Marek; Szawłowski, Marek; Grodzicki, Krystian

    2015-05-21

    The linearity of a silicon photomultiplier (SiPM) response depends on the number of APD cells and its effective recovery time and it is related to the intensity and duration of the detected light pulses. The aim of this study was to determine the effective recovery time on the basis of the measured SiPM response to light pulses of different durations. A closer analysis of the SiPM response to the light pulses shorter than the effective recovery time of APD cells led to a method for the evaluation of the single photoelectron response of the devices where the single photoelectron peak cannot be clearly measured. This is necessary in the evaluation of the number of fired APD cells (or the number of photoelectrons) in measurements with light pulses of various durations. Measurements were done with SiPMs manufactured by two companies: Hamamatsu and SensL.

  3. Using Response Times to Assess Learning Progress: A Joint Model for Responses and Response Times

    Science.gov (United States)

    Wang, Shiyu; Zhang, Susu; Douglas, Jeff; Culpepper, Steven

    2018-01-01

    Analyzing students' growth remains an important topic in educational research. Most recently, Diagnostic Classification Models (DCMs) have been used to track skill acquisition in a longitudinal fashion, with the purpose to provide an estimate of students' learning trajectories in terms of the change of fine-grained skills overtime. Response time…

  4. Threshold responses of Amazonian stream fishes to timing and extent of deforestation.

    Science.gov (United States)

    Brejão, Gabriel L; Hoeinghaus, David J; Pérez-Mayorga, María Angélica; Ferraz, Silvio F B; Casatti, Lilian

    2017-12-06

    Deforestation is a primary driver of biodiversity change through habitat loss and fragmentation. Stream biodiversity may not respond to deforestation in a simple linear relationship. Rather, threshold responses to extent and timing of deforestation may occur. Identification of critical deforestation thresholds is needed for effective conservation and management. We tested for threshold responses of fish species and functional groups to degree of watershed and riparian zone deforestation and time since impact in 75 streams in the western Brazilian Amazon. We used remote sensing to assess deforestation from 1984 to 2011. Fish assemblages were sampled with seines and dip nets in a standardized manner. Fish species (n = 84) were classified into 20 functional groups based on ecomorphological traits associated with habitat use, feeding, and locomotion. Threshold responses were quantified using threshold indicator taxa analysis. Negative threshold responses to deforestation were common and consistently occurred at very low levels of deforestation (70% deforestation and >10 years after impact. Findings were similar at the community level for both taxonomic and functional analyses. Because most negative threshold responses occurred at low levels of deforestation and soon after impact, even minimal change is expected to negatively affect biodiversity. Delayed positive threshold responses to extreme deforestation by a few species do not offset the loss of sensitive taxa and likely contribute to biotic homogenization. © 2017 Society for Conservation Biology.

  5. Improving linear accelerator service response with a real- time electronic event reporting system.

    Science.gov (United States)

    Hoisak, Jeremy D P; Pawlicki, Todd; Kim, Gwe-Ya; Fletcher, Richard; Moore, Kevin L

    2014-09-08

    To track linear accelerator performance issues, an online event recording system was developed in-house for use by therapists and physicists to log the details of technical problems arising on our institution's four linear accelerators. In use since October 2010, the system was designed so that all clinical physicists would receive email notification when an event was logged. Starting in October 2012, we initiated a pilot project in collaboration with our linear accelerator vendor to explore a new model of service and support, in which event notifications were also sent electronically directly to dedicated engineers at the vendor's technical help desk, who then initiated a response to technical issues. Previously, technical issues were reported by telephone to the vendor's call center, which then disseminated information and coordinated a response with the Technical Support help desk and local service engineers. The purpose of this work was to investigate the improvements to clinical operations resulting from this new service model. The new and old service models were quantitatively compared by reviewing event logs and the oncology information system database in the nine months prior to and after initiation of the project. Here, we focus on events that resulted in an inoperative linear accelerator ("down" machine). Machine downtime, vendor response time, treatment cancellations, and event resolution were evaluated and compared over two equivalent time periods. In 389 clinical days, there were 119 machine-down events: 59 events before and 60 after introduction of the new model. In the new model, median time to service response decreased from 45 to 8 min, service engineer dispatch time decreased 44%, downtime per event decreased from 45 to 20 min, and treatment cancellations decreased 68%. The decreased vendor response time and reduced number of on-site visits by a service engineer resulted in decreased downtime and decreased patient treatment cancellations.

  6. Filter frequency response of time dependent signal using Laplace transform

    Energy Technology Data Exchange (ETDEWEB)

    Shestakov, Aleksei I. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2018-01-16

    We analyze the effect a filter has on a time dependent signal x(t). If X(s) is the Laplace transform of x and H (s) is the filter Transfer function, the response in frequency space is X (s) H (s). Consequently, in real space, the response is the convolution (x*h) (t), where hi is the Laplace inverse of H. Effects are analyzed and analytically for functions such as (t/tc)2 e-t/t$_c$, where tc = const. We consider lowpass, highpass and bandpass filters.

  7. Caffeine-Induced Ca2+ Oscillations in Type I Horizontal Cells of the Carp Retina and the Contribution of the Store-Operated Ca2+ Entry Pathway

    Science.gov (United States)

    Lv, Ting; Gong, Hai-Qing; Liang, Pei-Ji

    2014-01-01

    The mechanisms of release, depletion, and refilling of endoplasmic reticulum (ER) Ca2+ were investigated in type I horizontal cells of the carp retina using a fluo-3-based Ca2+ imaging technique. Exogenous application of caffeine, a ryanodine receptor agonist, induced oscillatory intracellular free Ca2+ concentration ([Ca2+]i) responses in a duration- and concentration-dependent manner. In Ca2+-free Ringer’s solution, [Ca2+]i transients could also be induced by a brief caffeine application, whereas subsequent caffeine application induced no [Ca2+]i increase, which implied that extracellular Ca2+ was required for ER refilling, confirming the necessity of a Ca2+ influx pathway for ER refilling. Depletion of ER Ca2+ by thapsigargin triggered a Ca2+ influx which could be blocked by the store-operated channel inhibitor 2-APB, which proved the existence of the store-operated Ca2+ entry pathway. Taken together, these results suggested that after being depleted by caffeine, the ER was replenished by Ca2+ influx via store-operated channels. These results reveal the fine modulation of ER Ca2+ signaling, and the activation of the store-operated Ca2+ entry pathway guarantees the replenishment of the ER so that the cell can be ready for response to the subsequent stimulus. PMID:24918937

  8. Task modulation of the effects of brightness on reaction time and response force.

    Science.gov (United States)

    Jaśkowski, Piotr; Włodarczyk, Dariusz

    2006-08-01

    Van der Molen and Keuss [van der Molen, M.W., Keuss, P.J.G., 1979. The relationship between reaction time and intensity in discrete auditory tasks. Quarterly Journal of Experimental Psychology 31, 95-102; van der Molen, M.W., Keuss, P.J.G., 1981. Response selection and the processing of auditory intensity. Quarterly Journal of Experimental Psychology 33, 177-184] showed that paradoxically long reaction times (RT) occur with extremely loud auditory stimuli when the task is difficult (e.g. needs a response choice). It was argued that this paradoxical behavior of RT is due to active suppression of response prompting to prevent false responses. In the present experiments, we demonstrated that such an effect can also occur for visual stimuli provided that they are large enough. Additionally, we showed that response force exerted by participants on response keys monotonically grew with intensity for large stimuli but was independent of intensity for small visual stimuli. Bearing in mind that only large stimuli are believed to be arousing this pattern of results supports the arousal interpretation of the negative effect of loud stimuli on RT given by van der Molen and Keuss.

  9. Does spending time outdoors reduce stress? A review of real-time stress response to outdoor environments

    Science.gov (United States)

    Michelle C. Kondo; Sara F. Jacoby; Eugenia C. South

    2018-01-01

    Everyday environmental conditions impact human health. One mechanism underlying this relationship is the experience of stress. Through systematic review of published literature, we explore how stress has been measured in real-time non-laboratory studies of stress responses to deliberate exposure to outdoor environments. The types of exposures evaluated in this review...

  10. The Effect of Police Response Time on Crime Clearance Rates

    DEFF Research Database (Denmark)

    Blanes i Vidal, Jordi; Kirchmaier, Tom

    2018-01-01

    significant effects: in our preferred estimate, a 10% increase in response time leads to a 4.7 percentage points decrease in the likelihood of clearing the crime. We find stronger effects for thefts than for violent offenses, although the effects are large for every type of crime. We find suggestive evidence...

  11. Real-time information support for managing plant emergency responses

    International Nuclear Information System (INIS)

    Cain, D.G.; Lord, R.J.; Wilkinson, C.D.

    1983-01-01

    The Three Mile Island Unit 2 accident highlighted the need to develop a systematic approach to managing plant emergency responses, to identify a better decision-making process, and to implement real-time information support for decision-making. The overall process management function is described and general information requirements for management of plant emergencies are identified. Basic information systems are being incorporated and future extensions and problem areas are discussed. (U.K.)

  12. Response Time Analysis of Distributed Web Systems Using QPNs

    Directory of Open Access Journals (Sweden)

    Tomasz Rak

    2015-01-01

    Full Text Available A performance model is used for studying distributed Web systems. Performance evaluation is done by obtaining load test measurements. Queueing Petri Nets formalism supports modeling and performance analysis of distributed World Wide Web environments. The proposed distributed Web systems modeling and design methodology have been applied in the evaluation of several system architectures under different external loads. Furthermore, performance analysis is done to determine the system response time.

  13. Timing and position response of a block detector for fast neutron time-of-flight imaging

    Energy Technology Data Exchange (ETDEWEB)

    Laubach, M.A., E-mail: mlaubach@utk.edu [Department of Nuclear Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Hayward, J.P., E-mail: jhayward@utk.edu [Department of Nuclear Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Oak Ridge National Laboratory, 1 Bethel Valley Rd., Oak Ridge, TN 37831 (United States); Zhang, X., E-mail: xzhang39@utk.edu [Department of Nuclear Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Cates, J.W., E-mail: jcates7@vols.utk.edu [Department of Nuclear Engineering, University of Tennessee, Knoxville, TN 37996 (United States)

    2014-11-01

    Our research effort seeks to improve the spatial and timing performance of a block detector made of a pixilated plastic scintillator (EJ-200), first demonstrated as part of Oak Ridge National Laboratory's Advanced Portable Neutron Imaging System. Improvement of the position and time response is necessary to achieve better resolution and contrast in the images of shielded special nuclear material. Time-of-flight is used to differentiate between gamma and different sources of neutrons (e.g., transmission and fission neutrons). Factors limiting the timing and position performance of the neutron detector have been revealed through simulations and measurements. Simulations have suggested that the degradation in the ability to resolve pixels in the neutron detector is due to those interactions occurring near the light guide. The energy deposition within the neutron detector is shown to affect position performance and imaging efficiency. This examination details how energy cuts improve the position performance and degrade the imaging efficiency. Measurements have shown the neutron detector to have a timing resolution of σ=238 ps. The majority of this timing uncertainty is from the depth-of-interaction (DOI) of the neutron which is confirmed by simulations and analytical calculations.

  14. If climate action becomes urgent: The importance of response times for various climate strategies

    NARCIS (Netherlands)

    van Vuuren, D.P.; Stehfest, E.

    2013-01-01

    Most deliberations on climate policy are based on a mitigation response that assumes a gradually increasing reduction over time. However, situations may occur where a more urgent response is needed. A key question for climate policy in general, but even more in the case a rapid response is needed,

  15. Cardiorespiratory Dynamic Response to Mental Stress: A Multivariate Time-Frequency Analysis

    Directory of Open Access Journals (Sweden)

    Devy Widjaja

    2013-01-01

    out continuously in time to evaluate the dynamic response to mental stress and attention. The results show an increased heart and respiratory rate during stress and attention, compared to a resting condition. Also a fast reduction in vagal activity is noted. The partial TF analysis reveals a faster reduction of RRV power related to (3 s than unrelated to (30 s respiration, demonstrating that the autonomic response to mental stress is driven by mechanisms characterized by different temporal scales.

  16. Time response measurements of pressure sensors using pink noise technique

    International Nuclear Information System (INIS)

    Pereira, Iraci Martinez; Santos, Roberto Carlos dos

    2009-01-01

    This work presents an experimental setup for Pink Noise method application on pressure transmitters' response times. The Pink Noise method consists on injecting artificial pressure noise into the pressure transmitter. The artificial pressure noise is generated using a current-to-pressure (I-to-P) converter, which is driven by a random noise signal generator. The output pressure transmitter noise is then analyzed using conventional Noise Analysis Technique. Noise signals may be interpreted using spectral techniques or empirical time series models. The frequency domain method consists of evaluating the Power Spectral Density (PSD) function. The information needed for time constant estimation can be obtained by fitting an all-pole transfer function to this power spectral density. (author)

  17. Exactly solvable model for the time response function of RPCs

    International Nuclear Information System (INIS)

    Mangiarotti, A.; Fonte, P.; Gobbi, A.

    2004-01-01

    The fluctuation theory for the growth of several avalanches is briefly summarized and extended to include the case of electronegative gas mixtures. Based on such physical picture, the intrinsic time response function of an RPC can be calculated in a closed form and its average and rms extracted from series representations. The corresponding timing resolution, expressed in units of 1/((α-η)vd), is a universal function of the mean number of 'effective' clusters n0 reduced by electron attachment: n0(1-η/α). A comparison to a few selected good-quality experimental data is attempted for the timing resolution of both 1-gap and 4-gaps RPCs, finding a reasonable agreement

  18. A generalized linear factor model approach to the hierarchical framework for responses and response times.

    Science.gov (United States)

    Molenaar, Dylan; Tuerlinckx, Francis; van der Maas, Han L J

    2015-05-01

    We show how the hierarchical model for responses and response times as developed by van der Linden (2007), Fox, Klein Entink, and van der Linden (2007), Klein Entink, Fox, and van der Linden (2009), and Glas and van der Linden (2010) can be simplified to a generalized linear factor model with only the mild restriction that there is no hierarchical model at the item side. This result is valuable as it enables all well-developed modelling tools and extensions that come with these methods. We show that the restriction we impose on the hierarchical model does not influence parameter recovery under realistic circumstances. In addition, we present two illustrative real data analyses to demonstrate the practical benefits of our approach. © 2014 The British Psychological Society.

  19. Diabetic Driving Studies-Part 1: Brake Response Time in Diabetic Drivers With Lower Extremity Neuropathy.

    Science.gov (United States)

    Meyr, Andrew J; Spiess, Kerianne E

    Although the effect of lower extremity pathology and surgical intervention on automobile driving function has been a topic of contemporary interest, we are unaware of any analysis of the effect of lower extremity diabetic sensorimotor neuropathy on driving performance. The objective of the present case-control investigation was to assess the mean brake response time in diabetic drivers with lower extremity neuropathy compared with that of a control group and a brake response safety threshold. The driving performances of participants were evaluated using a computerized driving simulator with specific measurement of the mean brake response time and frequency of abnormally delayed brake responses. We analyzed a control group of 25 active drivers with neither diabetes nor lower extremity neuropathy and an experimental group of 25 active drivers with type 2 diabetes and lower extremity neuropathy. The experimental group demonstrated a 37.89% slower mean brake response time (0.757 ± 0.180 versus 0.549 ± 0.076 second; p time in the experimental group was slower than the reported safety brake response threshold of 0.70 second. The results of the present investigation provide original data with respect to abnormally delayed brake responses in diabetic patients with lower extremity neuropathy and might raise the potential for impaired driving function in this population. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Caire - A real-time feedback system for emergency response

    International Nuclear Information System (INIS)

    Braun, H.; Brenk, H.D.; de Witt, H.

    1991-01-01

    In cases of nuclear emergencies it is the primary task of emergency response forces and decision making authorities to act properly. Whatever the specific reason for the contingency may be, a quick and most accurate estimate of the radiation exposure in consequence of the emergency must be made. This is a necessary prerequisite for decisions on protective measures and off-site emergency management. With respect to this fact ant the recent experience of the Chernobyl accident, remote monitoring systems have increased their importance as an inherent part of environmental surveillance installations in the FRG and in other countries. The existing systems in Germany are designed to cover both, routine operation and emergency situations. They provide site specific meteorological data, gross effluent dose rates, and dose rate measurements at on-site and approximately 30 off-site locations in the vicinity of a plant. Based on such telemetric surveillance networks an advanced automatic on-line system named CAIRE (Computer Aided Response to Emergencies) has been developed as a real time emergency response tool for nuclear facilities. this tool is designed to provide decision makers with most relevant radiation exposure data of the population at risk. The development phase of CAIRE has already been finished. CAIRE is now in an operational status and available for applications in emergency planning and response

  1. AEROS: a real-time emergency response system for atmospheric releases of toxic material

    International Nuclear Information System (INIS)

    Nasstrom, J.S.; Greenly, G.D.

    1986-01-01

    The Atmospheric Release Advisory Capability (ARAC) at the Lawrence Livermore National Laboratory has developed a sophisticated computer-based real-time emergency response system for radiotoxic releases into the atmosphere. The ARAC Emergency Response Operating System (AEROS) has a centralized computer facility linked to remote site computers, meteorological towers, and meteorological data sources. The system supports certain fixed sites, but has the ability to respond to accidents at arbitrary locations. Product quality and response time are optimized by using complex three-dimensional dispersion models; extensive on-line data bases; automated data processing; and an efficient user interface, employing graphical computer displays and computer-displayed forms. Upon notification, the system automatically initiates a response to an emergency and proceeds through preliminary calculations, automatically processing accident information, meteorological data, and model parameters. The model calculations incorporate mass-consistent three-dimensional wind fields, terrain effects, and particle-in-cell diffusion. Model products are color images of dose or deposition contours overlaid on a base map

  2. Framework for estimating response time data to conduct a seismic human reliability analysis - its feasibility

    International Nuclear Information System (INIS)

    Park, Jinkyun; Kin, Yochan; Jung, Wondea; Jang, Seung Cheol

    2014-01-01

    This is because the PSA has been used for several decades as the representative tool to evaluate the safety of NPPs. To this end, it is inevitable to evaluate human error probabilities (HEPs) in conducting important tasks being considered in the PSA framework (i.e., HFEs; human failure events), which are able to significantly affect the safety of NPPs. In addition, it should be emphasized that the provision of a realistic human performance data is an important precondition for calculating HEPs under a seismic condition. Unfortunately, it seems that HRA methods being currently used for calculating HEPs under a seismic event do not properly consider the performance variation of human operators. For this reason, in this paper, a framework to estimate response time data that are critical for calculating HEPs is suggested with respect to a seismic intensity. This paper suggested a systematic framework for estimating response time data that would be one of the most critical for calculating HEPs. Although extensive review of existing literatures is indispensable for identifying response times of human operators who have to conduct a series of tasks prescribed in procedures based on a couple of wrong indications, it is highly expected that response time data for seismic HRA can be properly secured through revisiting response time data collected from diverse situations without concerning a seismic event

  3. Distinct Response Time Distributions in Attention Deficit Hyperactivity Disorder Subtypes

    Science.gov (United States)

    Querne, Laurent; Berquin, Patrick

    2009-01-01

    Objective: To address the issue of response time (RT) profiles in hyperactive-impulsive (ADHD-HI), inattentive (ADHD-IA), and combined (ADHD-C) subtypes of ADHD. We hypothesized that children with ADHD-HI should respond more rapidly than children without ADHD and children with ADHD-IA and ADHD-C should respond more slowly than children without…

  4. Real-time monitoring/emergency response modeling workstation for a tritium facility

    International Nuclear Information System (INIS)

    Lawver, B.S.; Sims, J.M.; Baskett, R.L.

    1993-01-01

    At Lawrence Livermore National Laboratory (LLNL) we have developed a real-time system to monitor two stacks on our tritium handling facility. The monitors transmit the stack data to a workstation, which computes a three-dimensional numerical model of atmospheric dispersion. The workstation also collects surface and upper air data from meteorological towers and a sodar. The complex meteorological and terrain setting in the Livermore Valley demands more sophisticated resolution of the three-dimensional structure of the atmosphere to reliably calculate plume dispersion than afforded by Gaussian models. We experience both mountain valley and sea breeze flows. To address these complexities, we have implemented the three-dimensional diagnostic MATHEW mass-adjusted wind field and ADPIC particle-in-cell dispersion models on the workstation for use in real-time emergency response modeling. Both MATHEW and ADPIC have shown their utility in a variety of complex settings over the last 15 yr within the U.S. Department of Energy's Atmospheric Release Advisory Capability (ARAC) project. Faster workstations and real-time instruments allow utilization of more complex three-dimensional models, which provides a foundation for building a real-time monitoring and emergency response workstation for a tritium facility. The stack monitors are two ion chambers per stack

  5. Motor response programming and movement time in children with heavy prenatal alcohol exposure.

    Science.gov (United States)

    Simmons, Roger W; Thomas, Jennifer D; Levy, Susan S; Riley, Edward P

    2010-06-01

    The present experiment assessed motor response programming and movement time in children with histories of heavy prenatal alcohol exposure (PEA). Alcohol-exposed children between the ages of 7 and 17 years were classified into two groups: Fetal Alcohol Syndrome (FAS: n=9) and children with PEA (PEA: n=19) but who did not have the defining characteristics of FAS. The FAS and PEA children were compared with non-alcohol-exposed children (NC: n=23) when completing two tasks: a simple reaction time task (RT alone condition) and a reaction plus movement task (RT+Move condition). The movement involved responding to an imperative stimulus signal and depressing three target buttons in a set sequence. Participants completed 24 trials each for the RT alone and RT+Move response conditions. Results indicated no significant differences in performance among FAS, PEA, and NC groups during the RT alone condition. However, during the RT+Move condition, the FAS group produced significantly longer and more variable RTs than the PEA and NC groups, which produced comparable RTs. The FAS group also produced significantly slower movement times when moving to all three targets, whereas movement time variability did not significantly differ as a function of group. The observed results indicate children with FAS experience deficits in response programming and movement time production. 2010 Elsevier Inc. All rights reserved.

  6. Dose-Response of Sodium Bicarbonate Ingestion Highlights Individuality in Time Course of Blood Analyte Responses.

    Science.gov (United States)

    Jones, Rebecca Louise; Stellingwerff, Trent; Artioli, Guilherme Giannini; Saunders, Bryan; Cooper, Simon; Sale, Craig

    2016-10-01

    To defend against hydrogen cation accumulation and muscle fatigue during exercise, sodium bicarbonate (NaHCO 3 ) ingestion is commonplace. The individualized dose-response relationship between NaHCO 3 ingestion and blood biochemistry is unclear. The present study investigated the bicarbonate, pH, base excess and sodium responses to NaHCO 3 ingestion. Sixteen healthy males (23 ± 2 years; 78.6 ± 15.1 kg) attended three randomized order-balanced, nonblinded sessions, ingesting a single dose of either 0.1, 0.2 or 0.3 g·kg -1 BM of NaHCO 3 (Intralabs, UK). Fingertip capillary blood was obtained at baseline and every 10 min for 1 hr, then every 15 min for a further 2 hr. There was a significant main effect of both time and condition for all assessed blood analytes (p ≤ .001). Blood analyte responses were significantly lower following 0.1 g·kg -1 BM compared with 0.2 g·kg -1 BM; bicarbonate concentrations and base excess were highest following ingestion of 0.3 g·kg -1 BM (p ≤ .01). Bicarbonate concentrations and pH significantly increased from baseline following all doses; the higher the dose the greater the increase. Large interindividual variability was shown in the magnitude of the increase in bicarbonate concentrations following each dose (+2.0-5; +5.1-8.1; and +6.0-12.3 mmol·L -1 for 0.1, 0.2 and 0.3 g·kg -1 BM) and in the range of time to peak concentrations (30-150; 40-165; and 75-180 min for 0.1, 0.2 and 0.3 g·kg -1 BM). The variability in bicarbonate responses was not affected by normalization to body mass. These results challenge current practices relating to NaHCO 3 supplementation and clearly show the need for athletes to individualize their ingestion protocol and trial varying dosages before competition.

  7. How to run ions in the future?

    International Nuclear Information System (INIS)

    Küchler, D; Manglunki, D; Scrivens, R

    2014-01-01

    In the light of different running scenarios potential source improvements will be discussed (e.g. one month every year versus two month every other year and impact of the different running options [e.g. an extended ion run] on the source). As the oven refills cause most of the down time the oven design and refilling strategies will be presented. A test stand for off-line developments will be taken into account. Also the implications on the necessary manpower for extended runs will be discussed

  8. Comparison of response times of a mobile-web EHRs system using PHP and JSP languages.

    Science.gov (United States)

    De la Torre-Díez, Isabel; Antón-Rodríguez, Míriam; Díaz-Pernas, Francisco Javier; Perozo-Rondón, Freddy José

    2012-12-01

    Performance evaluation is highly important in the Electronic Health Records (EHRs) system implementation. Response time's measurement can be considered as one manner to make that evaluation. In the e-health field, after the creation of EHRs available through different platforms such as Web and/or mobile, a performance evaluation is necessary. The operation of the system in the right way is essential. In this paper, a comparison of the response times for the MEHRmobile system is presented. The first version uses PHP language with a MySQL database and the second one employs JSP with an eXist database. Both versions have got the same functionalities. In addition to the technological aspects, a significant difference is the way the information is stored. The main goal of this paper is choosing the version which offers better response times. We have created a new benchmark to calculate the response times. Better results have been obtained for the PHP version. Nowadays, this version is being used for specialists from Fundación Intras, Spain.

  9. Temporal Prediction Errors Affect Short-Term Memory Scanning Response Time.

    Science.gov (United States)

    Limongi, Roberto; Silva, Angélica M

    2016-11-01

    The Sternberg short-term memory scanning task has been used to unveil cognitive operations involved in time perception. Participants produce time intervals during the task, and the researcher explores how task performance affects interval production - where time estimation error is the dependent variable of interest. The perspective of predictive behavior regards time estimation error as a temporal prediction error (PE), an independent variable that controls cognition, behavior, and learning. Based on this perspective, we investigated whether temporal PEs affect short-term memory scanning. Participants performed temporal predictions while they maintained information in memory. Model inference revealed that PEs affected memory scanning response time independently of the memory-set size effect. We discuss the results within the context of formal and mechanistic models of short-term memory scanning and predictive coding, a Bayes-based theory of brain function. We state the hypothesis that our finding could be associated with weak frontostriatal connections and weak striatal activity.

  10. Prediction of the human response time with the similarity and quantity of information

    International Nuclear Information System (INIS)

    Lee, Sungjin; Heo, Gyunyoung; Chang, Soon Heung

    2006-01-01

    Memory is one of brain processes that are important when trying to understand how people process information. Although a large number of studies have been made on the human performance, little is known about the similarity effect in human performance. The purpose of this paper is to propose and validate the quantitative and predictive model on the human response time in the user interface with the concept of similarity. However, it is not easy to explain the human performance with only similarity or information amount. We are confronted by two difficulties: making the quantitative model on the human response time with the similarity and validating the proposed model by experimental work. We made the quantitative model based on the Hick's law and the law of practice. In addition, we validated the model with various experimental conditions by measuring participants' response time in the environment of computer-based display. Experimental results reveal that the human performance is improved by the user interface's similarity. We think that the proposed model is useful for the user interface design and evaluation phases

  11. Lesions Responsible for Delayed Oral Transit Time in Post-stroke Dysphagia.

    Science.gov (United States)

    Moon, Hyun Im; Yoon, Seo Yeon; Yi, Tae Im; Jeong, Yoon Jeong; Cho, Tae Hwan

    2017-10-11

    Some stroke patients show oral phase dysphagia, characterized by a markedly prolonged oral transit time that hinders oral feeding. The aim of this study was to clarify the clinical characteristics and lesions responsible for delayed swallowing. We reviewed 90 patients with stroke. The oral processing time plus the postfaucial aggregation time required to swallow semisolid food was assessed. The patients were divided into two groups according to oral transit time, and we analyzed the differences in characteristics such as demographic factors, lesion factors, and cognitive function. Logistic regression analyses were performed to examine the predictors of delayed oral transit time. Lesion location and volume were measured on brain magnetic resonance images. We generated statistic maps of lesions related to delayed oral phase in swallowing using voxel-based lesion symptom mapping (VLSM). The group of patients who showed delayed oral transit time had significantly low cognitive function. Also, in a regression model, delayed oral phase was predicted with low K-MMSE (Korean version of the Mini Mental Status Exam). Using VLSM, we found the lesion location to be associated with delayed oral phase after adjusting for K-MMSE score. Although these results did not reach statistical significance, they showed the lesion pattern with predominant distribution in the left frontal lobe. Delayed oral phase in post-stroke patients was not negligible clinically. Patients' cognitive impairments affect the oral transit time. When adjusting it, we found a trend that the lesion responsible for delayed oral phase was located in the left frontal lobe, though the association did not reach significance. The delay might be related to praxis function.

  12. On the best learning algorithm for web services response time prediction

    DEFF Research Database (Denmark)

    Madsen, Henrik; Albu, Razvan-Daniel; Popentiu-Vladicescu, Florin

    2013-01-01

    In this article we will examine the effect of different learning algorithms, while training the MLP (Multilayer Perceptron) with the intention of predicting web services response time. Web services do not necessitate a user interface. This may seem contradictory to most people's concept of what...... an application is. A Web service is better imagined as an application "segment," or better as a program enabler. Performance is an important quality aspect of Web services because of their distributed nature. Predicting the response of web services during their operation is very important....

  13. Time-dependent leaf proteome alterations of Brachypodium distachyon in response to drought stress.

    Science.gov (United States)

    Tatli, Ozge; Sogutmaz Ozdemir, Bahar; Dinler Doganay, Gizem

    2017-08-01

    For the first time, a comprehensive proteome analysis was conducted on Brachypodium leaves under drought stress. Gradual changes in response to drought stress were monitored. Drought is one of the major stress factors that dramatically affect the agricultural productivity worldwide. Improving the yield under drought is an urgent challenge in agriculture. Brachypodium distachyon is a model species for monocot plants such as wheat, barley and several potential biofuel grasses. In the current study, a comprehensive proteome analysis was conducted on Brachypodium leaves under different levels of drought application. To screen gradual changes upon drought, Brachypodium leaves subjected to drought for 4, 8 and 12 days were collected for each treatment day and relative water content of the leaves was measured for each time point. Cellular responses of Brachypodium were investigated through a proteomic approach involving two dimensional difference gel electrophoresis (2D-DIGE) and mass spectrometry (MS). Among 497 distinct spots in Brachypodium protein repertoire, a total of 13 differentially expressed proteins (DEPs) were identified as responsive to drought by mass spectrometry and classified according to their functions using bioinformatics tools. The biological functions of DEPs included roles in photosynthesis, protein folding, antioxidant mechanism and metabolic processes, which responded differentially at each time point of drought treatment. To examine further transcriptional expression of the genes that code identified protein, quantitative real time PCR (qRT-PCR) was performed. Identified proteins will contribute to the studies involving development of drought-resistant crop species and lead to the delineation of molecular mechanisms in drought response.

  14. Toxicity evaluation of e-juice and its soluble aerosols generated by electronic cigarettes using recombinant bioluminescent bacteria responsive to specific cellular damages.

    Science.gov (United States)

    Bharadwaj, Shiv; Mitchell, Robert J; Qureshi, Anjum; Niazi, Javed H

    2017-04-15

    Electronic-cigarettes (e-cigarette) are widely used as an alternative to traditional cigarettes but their safety is not well established. Herein, we demonstrate and validate an analytical method to discriminate the deleterious effects of e-cigarette refills (e-juice) and soluble e-juice aerosol (SEA) by employing stress-specific bioluminescent recombinant bacterial cells (RBCs) as whole-cell biosensors. These RBCs carry luxCDABE-operon tightly controlled by promoters that specifically induced to DNA damage (recA), superoxide radicals (sodA), heavy metals (copA) and membrane damage (oprF). The responses of the RBCs following exposure to various concentrations of e-juice/SEA was recorded in real-time that showed dose-dependent stress specific-responses against both the e-juice and vaporized e-juice aerosols produced by the e-cigarette. We also established that high doses of e-juice (4-folds diluted) lead to cell death by repressing the cellular machinery responsible for repairing DNA-damage, superoxide toxicity, ion homeostasis and membrane damage. SEA also caused the cellular damages but the cells showed enhanced bioluminescence expression without significant growth inhibition, indicating that the cells activated their global defense system to repair these damages. DNA fragmentation assay also revealed the disintegration of total cellular DNA at sub-toxic doses of e-juice. Despite their state of matter, the e-juice and its aerosols induce cytotoxicity and alter normal cellular functions, respectively that raises concerns on use of e-cigarettes as alternative to traditional cigarette. The ability of RBCs in detecting both harmful effects and toxicity mechanisms provided a fundamental understanding of biological response to e-juice and aerosols. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Response time in online stated choice experiments

    DEFF Research Database (Denmark)

    Campbell, Danny; Mørkbak, Morten Raun; Olsen, Søren Bøye

    2017-01-01

    In this paper, we use paradata relating to the length of time respondents required in a self-administered online stated preference surveys. Although this issue has been previously explored, there is little guidance on how to identify and deal with ‘fast’ and ‘slow’ respondents. In this paper, we...... in Denmark. Results from our analysis corroborate that response latency has a bearing on the estimates of utility coefficients and the error variance. Although the results highlight the non-triviality of identifying fast and slow respondents, they signal the need to estimate a large number of candidate...... models to identify the most appropriate ‘fast’ and ‘slow’ thresholds. Not doing so is likely to lead to an inferior model and has repercussions for marginal willingness to pay estimates and choice predictions....

  16. The determinants of response time in a repeated constant-sum game: A robust Bayesian hierarchical dual-process model.

    Science.gov (United States)

    Spiliopoulos, Leonidas

    2018-03-01

    The investigation of response time and behavior has a long tradition in cognitive psychology, particularly for non-strategic decision-making. Recently, experimental economists have also studied response time in strategic interactions, but with an emphasis on either one-shot games or repeated social-dilemmas. I investigate the determinants of response time in a repeated (pure-conflict) game, admitting a unique mixed strategy Nash equilibrium, with fixed partner matching. Response times depend upon the interaction of two decision models embedded in a dual-process framework (Achtziger and Alós-Ferrer, 2014; Alós-Ferrer, 2016). The first decision model is the commonly used win-stay/lose-shift heuristic and the second the pattern-detecting reinforcement learning model in Spiliopoulos (2013b). The former is less complex and can be executed more quickly than the latter. As predicted, conflict between these two models (i.e., each one recommending a different course of action) led to longer response times than cases without conflict. The dual-process framework makes other qualitative response time predictions arising from the interaction between the existence (or not) of conflict and which one of the two decision models the chosen action is consistent with-these were broadly verified by the data. Other determinants of RT were hypothesized on the basis of existing theory and tested empirically. Response times were strongly dependent on the actions chosen by both players in the previous rounds and the resulting outcomes. Specifically, response time was shortest after a win in the previous round where the maximum possible payoff was obtained; response time after losses was significantly longer. Strongly auto-correlated behavior (regardless of its sign) was also associated with longer response times. I conclude that, similar to other tasks, there is a strong coupling in repeated games between behavior and RT, which can be exploited to further our understanding of decision

  17. Measurement of response time and detection of degradation in pressure sensor/sensing-line systems

    International Nuclear Information System (INIS)

    Buchanan, M.E.; Miller, L.F.; Kerlin, T.W.; Ragan, G.; March-Leuba, J.; Thie, J.A.

    1985-01-01

    A team evaluated several methods for remote measurement of the response time and detection of degradation (blockage or air in lines) of pressure sensor/sensing line systems typical of nuclear power plants. A method was developed for obtaining the response time of force-balance pressure transmitters by briefly interrupting the power supply to the transmitter. The data thus generated are then analyzed in conjunction with a model to predict transmitter response to an actual pressure perturbation. The research team also evaluated a pressure perturbation method for determining the asymptotic delay time of a pressure-sensing line and found that this method yields accurate results for essentially unblocked sensing lines. However, these pressure perturbation tests are not recommended for use in nuclear power plants because they are difficult to implement on-line. A third method for remote measurement applied noise analysis method that yielded accurate estimates of asymptotic delay times for blockage or air in sensing lines. Even though noise analysis methods worked well in the laboratory, it is recommended that further evaluation be performed in operating nuclear plants. (orig.)

  18. Measurement of response time and detection of degradation in pressure sensor/sensing line systems

    International Nuclear Information System (INIS)

    Buchanan, M.E.; Miller, L.F.; Thie, J.A.; Kerlin, T.W.; Ragan, G.E.; March-Leuba, J.

    1985-09-01

    A team evaluated several methods for remote measurement of the response time and detection of degradation (blockage or air in lines) of pressure sensor/sensing line systems typical of nuclear power plants. A method was developed for obtaining the response time of force-balance pressure transmitters by briefly interrupting the power supply to the transmitter. The data thus generated are then analyzed in conjunction with a model to predict transmitter response to an actual pressure perturbation. The research team also evaluated a pressure perturbation method for determining the asymptotic delay time of a pressure-sensing line and found that this method yields accurate results for essentially unblocked sensing lines. However, these pressure perturbation tests are not recommended for use in nuclear power plants because they are difficult to implement on-line. A third method for remote measurement applied noise analysis methods that yielded accurate estimates of asymptotic delay times for blockage or air in sensing lines. Even though noise analysis methods worked well in the laboratory, it is recommended that further evaluation be performed in operating nuclear plants

  19. Cardiorespiratory dynamic response to mental stress: a multivariate time-frequency analysis.

    Science.gov (United States)

    Widjaja, Devy; Orini, Michele; Vlemincx, Elke; Van Huffel, Sabine

    2013-01-01

    Mental stress is a growing problem in our society. In order to deal with this, it is important to understand the underlying stress mechanisms. In this study, we aim to determine how the cardiorespiratory interactions are affected by mental arithmetic stress and attention. We conduct cross time-frequency (TF) analyses to assess the cardiorespiratory coupling. In addition, we introduce partial TF spectra to separate variations in the RR interval series that are linearly related to respiration from RR interval variations (RRV) that are not related to respiration. The performance of partial spectra is evaluated in two simulation studies. Time-varying parameters, such as instantaneous powers and frequencies, are derived from the computed spectra. Statistical analysis is carried out continuously in time to evaluate the dynamic response to mental stress and attention. The results show an increased heart and respiratory rate during stress and attention, compared to a resting condition. Also a fast reduction in vagal activity is noted. The partial TF analysis reveals a faster reduction of RRV power related to (3 s) than unrelated to (30 s) respiration, demonstrating that the autonomic response to mental stress is driven by mechanisms characterized by different temporal scales.

  20. Using Response Times to Measure Strategic Complexity and the Value of Thinking in Games

    OpenAIRE

    Gill, David; Prowse, Victoria L.

    2017-01-01

    Response times are a simple low-cost indicator of the process of reasoning in strategic games (Rubinstein, 2007; Rubinstein, 2016). We leverage the dynamic nature of response-time data from repeated strategic interactions to measure the strategic complexity of a situation by how long people think on average when they face that situation (where we define situations according to the characteristics of play in the previous round). We find that strategic complexity varies significantly across sit...

  1. Seismic response time history analyses for KALIMER building with a horizontal and vertical seismic isolation

    International Nuclear Information System (INIS)

    Lee, J. H.; Yoo, B.; Koo, K. H.

    2001-01-01

    The seismic response time history analyses for the lumped mass models of KALIMER reactor building with a horizontal and vertical seismic isolation are performed for Artificial Time History and Kobe earthquake. The vertical amplification by the horizontal isolation is reduced by a vertical isolation for both earthquakes. The 3% viscous damping and the vertical isolation frequency of 1.5Hz gives a reduced vertical response compared to the fixed base condition at reactor support, and the 9% viscous damping to Kobe earthquake is required to get an equivalent vertical response with a fixed base condition

  2. Seismic response time history analyses for KALIMER building with a horizontal and vertical seismic isolation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. H.; Yoo, B.; Koo, K. H. [KAERI, Taejon (Korea, Republic of)

    2001-05-01

    The seismic response time history analyses for the lumped mass models of KALIMER reactor building with a horizontal and vertical seismic isolation are performed for Artificial Time History and Kobe earthquake. The vertical amplification by the horizontal isolation is reduced by a vertical isolation for both earthquakes. The 3% viscous damping and the vertical isolation frequency of 1.5Hz gives a reduced vertical response compared to the fixed base condition at reactor support, and the 9% viscous damping to Kobe earthquake is required to get an equivalent vertical response with a fixed base condition.

  3. Canada's international response to HIV during times of global transition: a qualitative inquiry.

    Science.gov (United States)

    Nixon, Stephanie

    2011-04-01

    Canada's international response to HIV may be under threat given CIDA's new aid priorities that appear to exclude health. Drivers of this recent priority shift have been the influence of global aid trends among public sector donors and changes within the global HIV milieu itself. However, this is not the first time Canada has shifted in response to these two global trends. The era from 2000-2004 also witnessed dramatic changes in both the HIV field and in global thinking around international aid. As such, this article presents an evaluation of the Government of Canada's international response to HIV during the first era of transition (2000-2004) in order to derive lessons for decision-making around HIV in the current climate of change. In-depth, semi-structured interviews were conducted with 23 key informants with expertise regarding Canada's international response to HIV over time. Analysis involved multiple readings of transcripts to identify descriptive codes and establish intimacy with the data. Descriptive codes were then collapsed into thematic categories using a process of inductive reasoning. Canada's international response to HIV was perceived to be exemplary at times (e.g. seminal funding to WHO's "3-by-5" strategy), but also inconsistent (e.g., underutilized technical assistance capacity) and non-strategic (e.g., contradiction between investing in training health providers while poaching professionals to bolster Canada's workforce). Lessons from the 2000-2004 era of transition focus on strategic investments, the inextricable connection between HIV and development and strategy coherence. These results highlight that it is more constructive to ensure that Canadian development responses in all areas engage with both the upstream drivers of HIV as well as the impacts of the epidemic itself in order to achieve the greatest results from international investment and the most effective contributions to the lives of the people that these endeavours seek to

  4. Technical Note: Response time evolution of XR-QA2 GafChromic™ film models.

    Science.gov (United States)

    Aldelaijan, Saad; Tomic, Nada; Papaconstadopoulos, Pavlos; Schneider, James; Seuntjens, Jan; Shih, Shelley; Lewis, David; Devic, Slobodan

    2018-01-01

    To evaluate the response of the newest XR-QA2 GafChromic™ film model in terms of postexposure signal growth and energy response in comparison with the older XR-QA (Version 2) model. Pieces of film were irradiated to air kerma in air values up to 12 cGy with several beam qualities (5.3-8.25 mm Al) commonly used for CT scanning. Film response was scored in terms of net reflectance from scanned film images at various points in time postirradiation ranging from 1 to 7 days and 5 months postexposure. To reconstruct the measurement signal changes with postirradiation delay, we irradiated one film piece and then scanned it at different point times starting from 2" min and up to 3 days postexposure. For all beam qualities and dose range investigated, it appears that the XR-QA2 film signal completely saturated after 15 h. Compared to 15 h postirradiation scanning time, the observed variation in net reflectance were 3%, 2%, and 1% for film scanned 2" min, 20 min, and 3 h after exposure, respectively, which is well within the measurement uncertainty of the XR-QA2 based reference radiochromic film dosimetry system. A comparison between the XR-QA (Version 2) and the XR-QA2 film response after several months (relative to their responses after 24 h) show differences in up to 8% and 1% for each film model respectively. The replacement of cesium bromide in the older XR-QA (Version 2) film model with bismuth oxide in the newer XR-QA2 film, while keeping the same single sensitive layer structure, lead to a significantly more stable postexposure response. © 2017 American Association of Physicists in Medicine.

  5. Competition for Antigen between Th1 and Th2 Responses Determines the Timing of the Immune Response Switch during Mycobaterium avium Subspecies paratuberulosis Infection in Ruminants

    Science.gov (United States)

    Magombedze, Gesham; Eda, Shigetoshi; Ganusov, Vitaly V.

    2014-01-01

    Johne's disease (JD), a persistent and slow progressing infection of ruminants such as cows and sheep, is caused by slow replicating bacilli Mycobacterium avium subspecies paratuberculosis (MAP) infecting macrophages in the gut. Infected animals initially mount a cell-mediated CD4 T cell response against MAP which is characterized by the production of interferon (Th1 response). Over time, Th1 response diminishes in most animals and antibody response to MAP antigens becomes dominant (Th2 response). The switch from Th1 to Th2 response occurs concomitantly with disease progression and shedding of the bacteria in feces. Mechanisms controlling this Th1/Th2 switch remain poorly understood. Because Th1 and Th2 responses are known to cross-inhibit each other, it is unclear why initially strong Th1 response is lost over time. Using a novel mathematical model of the immune response to MAP infection we show that the ability of extracellular bacteria to persist outside of macrophages naturally leads to switch of the cellular response to antibody production. Several additional mechanisms may also contribute to the timing of the Th1/Th2 switch including the rate of proliferation of Th1/Th2 responses at the site of infection, efficiency at which immune responses cross-inhibit each other, and the rate at which Th1 response becomes exhausted over time. Our basic model reasonably well explains four different kinetic patterns of the Th1/Th2 responses in MAP-infected sheep by variability in the initial bacterial dose and the efficiency of the MAP-specific T cell responses. Taken together, our novel mathematical model identifies factors of bacterial and host origin that drive kinetics of the immune response to MAP and provides the basis for testing the impact of vaccination or early treatment on the duration of infection. PMID:24415928

  6. Spatial Attention and Temporal Expectation Under Timed Uncertainty Predictably Modulate Neuronal Responses in Monkey V1

    Science.gov (United States)

    Sharma, Jitendra; Sugihara, Hiroki; Katz, Yarden; Schummers, James; Tenenbaum, Joshua; Sur, Mriganka

    2015-01-01

    The brain uses attention and expectation as flexible devices for optimizing behavioral responses associated with expected but unpredictably timed events. The neural bases of attention and expectation are thought to engage higher cognitive loci; however, their influence at the level of primary visual cortex (V1) remains unknown. Here, we asked whether single-neuron responses in monkey V1 were influenced by an attention task of unpredictable duration. Monkeys covertly attended to a spot that remained unchanged for a fixed period and then abruptly disappeared at variable times, prompting a lever release for reward. We show that monkeys responded progressively faster and performed better as the trial duration increased. Neural responses also followed monkey's task engagement—there was an early, but short duration, response facilitation, followed by a late but sustained increase during the time monkeys expected the attention spot to disappear. This late attentional modulation was significantly and negatively correlated with the reaction time and was well explained by a modified hazard function. Such bimodal, time-dependent changes were, however, absent in a task that did not require explicit attentional engagement. Thus, V1 neurons carry reliable signals of attention and temporal expectation that correlate with predictable influences on monkeys' behavioral responses. PMID:24836689

  7. Natural excitation orbitals from linear response theories : Time-dependent density functional theory, time-dependent Hartree-Fock, and time-dependent natural orbital functional theory

    NARCIS (Netherlands)

    Van Meer, R.; Gritsenko, O. V.; Baerends, E. J.

    2017-01-01

    Straightforward interpretation of excitations is possible if they can be described as simple single orbital-to-orbital (or double, etc.) transitions. In linear response time-dependent density functional theory (LR-TDDFT), the (ground state) Kohn-Sham orbitals prove to be such an orbital basis. In

  8. Solving a Location, Allocation, and Capacity Planning Problem with Dynamic Demand and Response Time Service Level

    Directory of Open Access Journals (Sweden)

    Carrie Ka Yuk Lin

    2014-01-01

    Full Text Available Logistic systems with uncertain demand, travel time, and on-site processing time are studied here where sequential trip travel is allowed. The relationship between three levels of decisions: facility location, demand allocation, and resource capacity (number of service units, satisfying the response time requirement, is analysed. The problem is formulated as a stochastic mixed integer program. A simulation-based hybrid heuristic is developed to solve the dynamic problem under different response time service level. An initial solution is obtained from solving static location-allocation models, followed by iterative improvement of the three levels of decisions by ejection, reinsertion procedure with memory of feasible and infeasible service regions. Results indicate that a higher response time service level could be achieved by allocating a given resource under an appropriate decentralized policy. Given a response time requirement, the general trend is that the minimum total capacity initially decreases with more facilities. During this stage, variability in travel time has more impact on capacity than variability in demand arrivals. Thereafter, the total capacity remains stable and then gradually increases. When service level requirement is high, the dynamic dispatch based on first-come-first-serve rule requires smaller capacity than the one by nearest-neighbour rule.

  9. Dependence of ionospheric response on the local time of sudden commencement and the intensity of geomagnetic storms

    International Nuclear Information System (INIS)

    Balan, N.; Rao, P.B.

    1990-01-01

    A study has been designed specifically to investigate the dependence of the ionospheric response on the time of occurrence of sudden commencement (SC) and the intensity of the magnetic storms for a low- and a mid-latitude station by considering total electron content and peak electron density data for more than 60 SC-type geomagnetic storms. The nature of the response, whether positive or negative, is found to be determined largely by the local time of SC, although there is a local time shift of about six hours between low- and mid-latitudes. The time delays associated with the positive responses are low for daytime SCs and high for night-time SCs, whereas the opposite applies for negative responses. The time delays are significantly shorter for mid-latitudes than for low-latitudes and, at both latitudes, are inversely related to the intensity of the storm. There is a positive correlation between the intensity of the ionospheric response and that of the magnetic storm, the correlation being greater at mid-latitudes. The results are discussed in the light of the possible processes which might contribute to the storm-associated ionospheric variations. (author)

  10. Real-time fluorescence imaging of the DNA damage repair response during mitosis.

    Science.gov (United States)

    Miwa, Shinji; Yano, Shuya; Yamamoto, Mako; Matsumoto, Yasunori; Uehara, Fuminari; Hiroshima, Yukihiko; Toneri, Makoto; Murakami, Takashi; Kimura, Hiroaki; Hayashi, Katsuhiro; Yamamoto, Norio; Efimova, Elena V; Tsuchiya, Hiroyuki; Hoffman, Robert M

    2015-04-01

    The response to DNA damage during mitosis was visualized using real-time fluorescence imaging of focus formation by the DNA-damage repair (DDR) response protein 53BP1 linked to green fluorescent protein (GFP) (53BP1-GFP) in the MiaPaCa-2(Tet-On) pancreatic cancer cell line. To observe 53BP1-GFP foci during mitosis, MiaPaCa-2(Tet-On) 53BP1-GFP cells were imaged every 30 min by confocal microscopy. Time-lapse imaging demonstrated that 11.4 ± 2.1% of the mitotic MiaPaCa-2(Tet-On) 53BP1-GFP cells had increased focus formation over time. Non-mitotic cells did not have an increase in 53BP1-GFP focus formation over time. Some of the mitotic MiaPaCa-2(Tet-On) 53BP1-GFP cells with focus formation became apoptotic. The results of the present report suggest that DNA strand breaks occur during mitosis and undergo repair, which may cause some of the mitotic cells to enter apoptosis in a phenomenon possibly related to mitotic catastrophe. © 2014 Wiley Periodicals, Inc.

  11. Capturing Real-Time Data in Disaster Response Logistics

    Directory of Open Access Journals (Sweden)

    Kezban Yagci Sokat

    2016-06-01

    Full Text Available The volume, accuracy, accessibility and level of detail of near real-time data emerging from disaster-affected regions continue to significantly improve. Integration of dynamically evolving in-field data is an important, yet often overlooked, component of the humanitarian logistics models. In this paper, we present a framework for real-time humanitarian logistics data focused on use in mathematical modeling along with modeling implications of this framework. We also discuss how one might measure the attributes of the framework and describe the application of the presented framework to a case study of near real-time data collection in the days following the landfall of Typhoon Haiyan. We detail our first-hand experience of capturing data as the post-disaster response unfolds starting on November 10, 2013 until March 31, 2014 and assess the characteristics and evolution of data pertaining to humanitarian logistics modeling using the proposed framework. The presented logistical content analysis examines the availability of data and informs modelers about the current state of near real-time data. This analysis illustrates what data is available, how early it is available, and how data changes after the disaster. The study describes how our humanitarian logistics team approached the emergence of dynamic online data after the disaster and the challenges faced during the collection process, as well as recommendations to address these challenges in the future (when possible from an academic humanitarian logistics perspective.

  12. Time series analysis of wind speed using VAR and the generalized impulse response technique

    Energy Technology Data Exchange (ETDEWEB)

    Ewing, Bradley T. [Area of Information Systems and Quantitative Sciences, Rawls College of Business and Wind Science and Engineering Research Center, Texas Tech University, Lubbock, TX 79409-2101 (United States); Kruse, Jamie Brown [Center for Natural Hazard Research, East Carolina University, Greenville, NC (United States); Schroeder, John L. [Department of Geosciences and Wind Science and Engineering Research Center, Texas Tech University, Lubbock, TX (United States); Smith, Douglas A. [Department of Civil Engineering and Wind Science and Engineering Research Center, Texas Tech University, Lubbock, TX (United States)

    2007-03-15

    This research examines the interdependence in time series wind speed data measured in the same location at four different heights. A multiple-equation system known as a vector autoregression is proposed for characterizing the time series dynamics of wind. Additionally, the recently developed method of generalized impulse response analysis provides insight into the cross-effects of the wind series and their responses to shocks. Findings are based on analysis of contemporaneous wind speed time histories taken at 13, 33, 70 and 160 ft above ground level with a sampling rate of 10 Hz. The results indicate that wind speeds measured at 70 ft was the most variable. Further, the turbulence persisted longer at the 70-ft measurement than at the other heights. The greatest interdependence is observed at 13 ft. Gusts at 160 ft led to the greatest persistence to an 'own' shock and led to greatest persistence in the responses of the other wind series. (author)

  13. H.R. 754: A Bill to make improvements in the Black Lung Benefits Act. Introduced in the House of Representatives, One Hundred Fourth Congress, First session

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    This bill proposes changes in the Black Lung Benefits Act with the intent of improving the existing legislation. Changes are proposed in sections of the act referring to: benefit overpayment; evidence; survivor benefits; responsible operator; attorney fees; administration; refilling; construction; and effective dates.

  14. Equilibrium and response properties of the integrate-and-fire neuron in discrete time

    Directory of Open Access Journals (Sweden)

    Moritz Helias

    2010-01-01

    Full Text Available The integrate-and-fire neuron with exponential postsynaptic potentials is a frequently employed model to study neural networks. Simulations in discrete time still have highest performance at moderate numerical errors, which makes them first choice for long-term simulations of plastic networks. Here we extend the population density approach to investigate how the equilibrium and response properties of the leaky integrate-and-fire neuron are affected by time discretization. We present a novel analytical treatment of the boundary condition at threshold, taking both discretization of time and finite synaptic weights into account. We uncover an increased membrane potential density just below threshold as the decisive property that explains the deviations found between simulations and the classical diffusion approximation. Temporal discretization and finite synaptic weights both contribute to this effect. Our treatment improves the standard formula to calculate the neuron’s equilibrium firing rate. Direct solution of the Markov process describing the evolution of the membrane potential density confirms our analysis and yields a method to calculate the firing rate exactly. Knowing the shape of the membrane potential distribution near threshold enables us to devise the transient response properties of the neuron model to synaptic input. We find a pronounced non-linear fast response component that has not been described by the prevailing continuous time theory for Gaussian white noise input.

  15. Application of Time Domain PARET to the measured responses of a building

    International Nuclear Information System (INIS)

    Lager, D.L.

    1979-01-01

    The application of the Time Domain PARET (TDP) algorithm to data obtained from the measured responses of a three story reinforced concrete building approximately 465 feet long by 220 feet wide by 40 feet high, with 12 to 18 inch thick walls, is described. The measurements were taken by Agbabian Associates, El Segundo, California. The structure was excited by a device developed at Agbabian that uses a mass sliding down a rod to cut metal disks attached to the rod. The result is a series of impulse forces driving the building at the attachment point of the rod. The responses measured were the accelerations at two locations on the structure. A constraint imposed was that the equipment in the building must remain operating during the time the measurements were made

  16. Ultralong time response of magnetic fluid based on fiber-optic evanescent field.

    Science.gov (United States)

    Du, Bobo; Yang, Dexing; Bai, Yang; Yuan, Yuan; Xu, Jian; Jiang, Yajun; Wang, Meirong

    2016-07-20

    The ultralong time (a few hours) response properties of magnetic fluid using etched optical fiber are visualized and investigated experimentally. The operating structure is made by injecting magnetic fluid into a capillary tube that contains etched single-mode fiber. An interesting extreme asymmetry is observed, in which the transmitted light intensity after the etched optical fiber cannot reach the final steady value when the external magnetic field is turned on (referred to as the falling process), while it can reach the stable state quickly once the magnetic field is turned off (referred to as the rising process). The relationship between the response times/loss rates of the transmitted light and the strength of the applied magnetic field is obtained. The physical mechanisms of two different processes are discussed qualitatively.

  17. Time to treatment as an important factor for the response to methotrexate in juvenile idiopathic arthritis.

    Science.gov (United States)

    Albers, H M; Wessels, J A M; van der Straaten, R J H M; Brinkman, D M C; Suijlekom-Smit, L W A; Kamphuis, S S M; Girschick, H J; Wouters, C; Schilham, M W; le Cessie, S; Huizinga, T W J; Ten Cate, R; Guchelaar, H J

    2009-01-15

    Methotrexate (MTX) is the most commonly used disease-modifying antirheumatic drug in juvenile idiopathic arthritis (JIA). Currently, individual response to MTX cannot be reliably predicted. Identification of clinical and genetic factors that influence the response to MTX could be helpful in realizing the optimal treatment for individual patients. A cohort of 128 JIA patients treated with MTX were studied retrospectively. Eleven clinical parameters and genotypes of 6 single nucleotide polymorphisms in 5 genes related to the mechanism of action of MTX were compared between MTX responders and nonresponders using a multivariate regression analysis. The time from diagnosis to start of MTX treatment, physician's global assessment at baseline, and the starting dose were significantly associated with the response to MTX at 6 months after initiation. Patients with a shorter time from diagnosis to start of MTX and a higher disease activity according to the physician but with a lower MTX dose showed an increased response. The effect of the starting dose on MTX response seemed to be mainly due to the influence of the systemic JIA subtype. The time from diagnosis to start of MTX treatment and physician's global assessment at baseline were highly correlated. Therefore, the precise effect size of each independent variable could not be determined. In children with JIA, the time from diagnosis to start of MTX appears to be an important factor for MTX response. Our results suggest that an earlier start of MTX treatment will lead to an increased response.

  18. Time-based prospective memory in young children-Exploring executive functions as a developmental mechanism.

    Science.gov (United States)

    Kretschmer, Anett; Voigt, Babett; Friedrich, Sylva; Pfeiffer, Kathrin; Kliegel, Matthias

    2014-01-01

    The present study investigated time-based prospective memory (PM) during the transition from kindergarten/preschool to school age and applied mediation models to test the impact of executive functions (working memory, inhibitory control) and time monitoring on time-based PM development. Twenty-five preschool (age: M = 5.75, SD = 0.28) and 22 primary school children (age: M = 7.83, SD = 0.39) participated. To examine time-based PM, children had to play a computer-based driving game requiring them to drive a car on a road without hitting others cars (ongoing task) and to refill the car regularly according to a fuel gauge, which serves as clock equivalent (PM task). The level of gas that was still left in the fuel gauge was not displayed on the screen and children had to monitor it via a button press (time monitoring). Results revealed a developmental increase in time-based PM performance from preschool to school age. Applying the mediation models, only working memory was revealed to influence PM development. Neither inhibitory control alone nor the mediation paths leading from both executive functions to time monitoring could explain the link between age and time-based PM. Thus, results of the present study suggest that working memory may be one key cognitive process driving the developmental growth of time-based PM during the transition from preschool to school age.

  19. Drought, Frost, Rain and Sunshine. Four Years of Sap Flow Measurements for One of the World's Largest Conifers

    Science.gov (United States)

    Macinnis-Ng, C.; Taylor, D. T.; Kaplick, J.; Clearwater, M.

    2015-12-01

    Amongst the largest and longest lived conifers in the world, the endemic New Zealand kauri, Agathis australis, provides a proxy-climate record dating back 4000 y. Tree-ring widths provide a strong indicator of the occurrence of El Niño Southern Oscillation (ENSO) events. We are measuring physiological processes, including carbon uptake and loss, leaf-scale gas exchange and sap flow together with meteorological data to explore the mechanisms of the climate response of this iconic and culturally significant species. In this continuous 15 min time interval sap flow dataset spanning four years, we have captured very wet and very dry summer periods. Winter flow rates peaked lower than summer flow rates and winter flow also started later and finished earlier in the day, resulting in less water use. Larger, canopy dominant trees (DBH up to 176 cm) had large sapwood area (sapwood depth up to 18 cm) and faster flow rates and therefore dominated stand water use. During dry periods, smaller trees (DBH 20-80 cm) were more responsive to dry soils than larger trees, suggesting access to deeper soil water stores. Leaf-scale gas exchange rates were low with very low stomatal conductance values reflecting known vulnerability to xylem embolism. Night-time refilling of sapwood was particularly evident during the summer drought with evidence that refilling was incomplete as the drought progressed. Photosynthetically active radiation and vapour pressure deficit are strongly correlated with sap flow across all seasons, a promising indicator for future modelling work on this dataset. Water saving strategies and stand-scale water budgets are discussed.

  20. A study of response time of pitot pressure probes designed for rapid response and protection of transducer

    Science.gov (United States)

    Moore, J. A.

    1979-01-01

    An eight orifice probe, designed to protect the transducer without the use of a baffle, was compared to a standard orifice-baffle probe in the small shock tube and in the expansion tube under normal run conditions. In both facilities, the response time of eight orifice probe was considerable better than the standard probe design.

  1. Association of Bystander Cardiopulmonary Resuscitation and Survival According to Ambulance Response Times After Out-of-Hospital Cardiac Arrest.

    Science.gov (United States)

    Rajan, Shahzleen; Wissenberg, Mads; Folke, Fredrik; Hansen, Steen Møller; Gerds, Thomas A; Kragholm, Kristian; Hansen, Carolina Malta; Karlsson, Lena; Lippert, Freddy K; Køber, Lars; Gislason, Gunnar H; Torp-Pedersen, Christian

    2016-12-20

    Bystander-initiated cardiopulmonary resuscitation (CPR) increases patient survival after out-of-hospital cardiac arrest, but it is unknown to what degree bystander CPR remains positively associated with survival with increasing time to potential defibrillation. The main objective was to examine the association of bystander CPR with survival as time to advanced treatment increases. We studied 7623 out-of-hospital cardiac arrest patients between 2005 and 2011, identified through the nationwide Danish Cardiac Arrest Registry. Multiple logistic regression analysis was used to examine the association between time from 911 call to emergency medical service arrival (response time) and survival according to whether bystander CPR was provided (yes or no). Reported are 30-day survival chances with 95% bootstrap confidence intervals. With increasing response times, adjusted 30-day survival chances decreased for both patients with bystander CPR and those without. However, the contrast between the survival chances of patients with versus without bystander CPR increased over time: within 5 minutes, 30-day survival was 14.5% (95% confidence interval [CI]: 12.8-16.4) versus 6.3% (95% CI: 5.1-7.6), corresponding to 2.3 times higher chances of survival associated with bystander CPR; within 10 minutes, 30-day survival chances were 6.7% (95% CI: 5.4-8.1) versus 2.2% (95% CI: 1.5-3.1), corresponding to 3.0 times higher chances of 30-day survival associated with bystander CPR. The contrast in 30-day survival became statistically insignificant when response time was >13 minutes (bystander CPR vs no bystander CPR: 3.7% [95% CI: 2.2-5.4] vs 1.5% [95% CI: 0.6-2.7]), but 30-day survival was still 2.5 times higher associated with bystander CPR. Based on the model and Danish out-of-hospital cardiac arrest statistics, an additional 233 patients could potentially be saved annually if response time was reduced from 10 to 5 minutes and 119 patients if response time was reduced from 7 (the median

  2. The nitrate response of a lowland catchment and groundwater travel times

    Science.gov (United States)

    van der Velde, Ype; Rozemeijer, Joachim; de Rooij, Gerrit; van Geer, Frans

    2010-05-01

    Intensive agriculture in lowland catchments causes eutrophication of downstream waters. To determine effective measures to reduce the nutrient loads from upstream lowland catchments, we need to understand the origin of long-term and daily variations in surface water nutrient concentrations. Surface water concentrations are often linked to travel time distributions of water passing through the saturated and unsaturated soil of the contributing catchment. This distribution represents the contact time over which sorption, desorption and degradation takes place. However, travel time distributions are strongly influenced by processes like tube drain flow, overland flow and the dynamics of draining ditches and streams and therefore exhibit strong daily and seasonal variations. The study we will present is situated in the 6.6 km2 Hupsel brook catchment in The Netherlands. In this catchment nitrate and chloride concentrations have been intensively monitored for the past 26 years under steadily decreasing agricultural inputs. We described the complicated dynamics of subsurface water fluxes as streams, ditches and tube drains locally switch between active or passive depending on the ambient groundwater level by a groundwater model with high spatial and temporal resolutions. A transient particle tracking approach is used to derive a unique catchment-scale travel time distribution for each day during the 26 year model period. These transient travel time distributions are not smooth distributions, but distributions that are strongly spiked reflecting the contribution of past rainfall events to the current discharge. We will show that a catchment-scale mass response function approach that only describes catchment-scale mixing and degradation suffices to accurately reproduce observed chloride and nitrate surface water concentrations as long as the mass response functions include the dynamics of travel time distributions caused by the highly variable connectivity of the surface

  3. Time-Lag in Responses of Birds to Atlantic Forest Fragmentation: Restoration Opportunity and Urgency.

    Science.gov (United States)

    Uezu, Alexandre; Metzger, Jean Paul

    2016-01-01

    There are few opportunities to evaluate the relative importance of landscape structure and dynamics upon biodiversity, especially in highly fragmented tropical landscapes. Conservation strategies and species risk evaluations often rely exclusively on current aspects of landscape structure, although such limited assumptions are known to be misleading when time-lag responses occur. By relating bird functional-group richness to forest patch size and isolation in ten-year intervals (1956, 1965, 1978, 1984, 1993 and 2003), we revealed that birds with different sensitivity to fragmentation display contrasting responses to landscape dynamics in the Brazilian Atlantic Forest. For non-sensitive groups, there was no time-lag in response: the recent degree of isolation best explains their variation in richness, which likely relates to these species' flexibility to adapt to changes in landscape structure. However, for sensitive bird groups, the 1978 patch area was the best explanatory variable, providing evidence for a 25-year time-lag in response to habitat reduction. Time-lag was more likely in landscapes that encompass large patches, which can support temporarily the presence of some sensitive species, even when habitat cover is relatively low. These landscapes potentially support the most threatened populations and should be priorities for restoration efforts to avoid further species loss. Although time-lags provide an opportunity to counteract the negative consequences of fragmentation, it also reinforces the urgency of restoration actions. Fragmented landscapes will be depleted of biodiversity if landscape structure is only maintained, and not improved. The urgency of restoration action may be even higher in landscapes where habitat loss and fragmentation history is older and where no large fragment remained to act temporarily as a refuge.

  4. Time response of protection in event of vacuum failure based on Nude ionization gauge controller

    Science.gov (United States)

    Gao, Hui; Wang, Qiuping; Wang, Weibin; Wu, Qinglin; Chen, Wentong; Sheng, Liusi; Zhang, Yunwu

    2001-10-01

    This article describes the design and application of fast-response vacuum protection sensor module, based on the Nude ionization gauge and a homemade controller named GH07X. A simulative test indicated that the controller's response time was less than 200 μs when 1 atm air rushed into the vacuum system through a pulsed valve with 0.8 mm orifice nozzle and the emitting current of the Nude gauge was 4 mA. The experiment result showed that the response time mainly depended on the gas density as well as the electron emitting current of the Nude gauge filament. Compared with the vacuum protection sensors based on sputter ion pump and cold-cathode gauge, GH07X is faster and reliable besides, GH07X can be used as an ultrahigh-vacuum slow valve interlock controller with response time of 100 ms, which is faster than other gauge controllers. The widely used field-bus interface CAN and common serial interface RS232/RS485 are embedded in GH07X controller system.

  5. Real-Time Gas Identification by Analyzing the Transient Response of Capillary-Attached Conductive Gas Sensor

    Directory of Open Access Journals (Sweden)

    Behzad Bahraminejad

    2010-05-01

    Full Text Available In this study, the ability of the Capillary-attached conductive gas sensor (CGS in real-time gas identification was investigated. The structure of the prototype fabricated CGS is presented. Portions were selected from the beginning of the CGS transient response including the first 11 samples to the first 100 samples. Different feature extraction and classification methods were applied on the selected portions. Validation of methods was evaluated to study the ability of an early portion of the CGS transient response in target gas (TG identification. Experimental results proved that applying extracted features from an early part of the CGS transient response along with a classifier can distinguish short-chain alcohols from each other perfectly. Decreasing time of exposition in the interaction between target gas and sensing element improved the reliability of the sensor. Classification rate was also improved and time of identification was decreased. Moreover, the results indicated the optimum interval of the early transient response of the CGS for selecting portions to achieve the best classification rates.

  6. MO-FG-BRA-03: A Novel Method for Characterizing Gating Response Time in Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Wiersma, R; McCabe, B; Belcher, A; Jenson, P [The University of Chicago, Chicago, IL (United States); Smith, B [University Illinois at Chicago, Orland Park, IL (United States); Aydogan, B [The University of Chicago, Chicago, IL (United States); University Illinois at Chicago, Orland Park, IL (United States)

    2016-06-15

    Purpose: Low temporal latency between a gating ON/OFF signal and the LINAC beam ON/OFF during respiratory gating is critical for patient safety. Current film based methods to assess gating response have poor temporal resolution and are highly qualitative. We describe a novel method to precisely measure gating lag times at high temporal resolutions and use it to characterize the temporal response of several gating systems. Methods: A respiratory gating simulator with an oscillating platform was modified to include a linear potentiometer for position measurement. A photon diode was placed at linear accelerator isocenter for beam output measurement. The output signals of the potentiometer and diode were recorded simultaneously at 2500 Hz (0.4 millisecond (ms) sampling interval) with an analogue-to-digital converter (ADC). The techniques was used on three commercial respiratory gating systems. The ON and OFF of the beam signal were located and compared to the expected gating window for both phase and position based gating and the temporal lag times extracted using a polynomial fit method. Results: A Varian RPM system with a monoscopic IR camera was measured to have mean beam ON and OFF lag times of 98.2 ms and 89.6 ms, respectively. A Varian RPM system with a stereoscopic IR camera was measured to have mean beam ON and OFF lag times of 86.0 ms and 44.0 ms, respectively. A Calypso magnetic fiducial tracking system was measured to have mean beam ON and OFF lag times of 209.0 ms and 60.0 ms, respectively. Conclusions: A novel method allowed for quantitative determination of gating timing accuracy for several clinically used gating systems. All gating systems met the 100 ms TG-142 criteria for mean beam OFF times. For beam ON response, the Calypso system exceeded the recommended response time.

  7. Determination of the response time of pressure transducers using the direct method

    International Nuclear Information System (INIS)

    Perillo, S.R.P.

    1994-01-01

    The available methods to determine the response time of nuclear safety related pressure transducers are discussed, with emphasis to the direct method. In order to perform the experiments, a Hydraulic Ramp Generator was built. The equipment produces ramp pressure transients simultaneously to a reference transducer and to the transducer under test. The time lag between the output of the two transducers, when they reach a predetermined setpoint, is measured as the time delay of the transducer under test. Some results using the direct method to determine the time delay of pressure transducers (1 E Class Conventional) are presented. (author). 18 refs, 35 figs, 12 tabs

  8. Response time distributions in rapid chess: A large-scale decision making experiment

    Directory of Open Access Journals (Sweden)

    Mariano Sigman

    2010-10-01

    Full Text Available Rapid chess provides an unparalleled laboratory to understand decision making in a natural environment. In a chess game, players choose consecutively around 40 moves in a finite time budget. The goodness of each choice can be determined quantitatively since current chess algorithms estimate precisely the value of a position. Web-based chess produces vast amounts of data, millions of decisions per day, incommensurable with traditional psychological experiments. We generated a database of response times and position value in rapid chess games. We measured robust emergent statistical observables: 1 Response time (RT distributions are long-tailed and show qualitatively distinct forms at different stages of the game, 2 RT of successive moves are highly correlated both for intra- and inter-player moves. These findings have theoretical implications since they deny two basic assumptions of sequential decision making algorithms: RTs are not stationary and can not be generated by a state function. Our results also have practical implications. First, we characterized the capacity of blunders and score fluctuations to predict a player strength, which is yet an open problem in chess softwares. Second, we show that the winning likelihood can be reliably estimated from a weighted combination of remaining times and position evaluation.

  9. Norepinephrine genes predict response time variability and methylphenidate-induced changes in neuropsychological function in attention deficit hyperactivity disorder.

    Science.gov (United States)

    Kim, Bung-Nyun; Kim, Jae-Won; Cummins, Tarrant D R; Bellgrove, Mark A; Hawi, Ziarih; Hong, Soon-Beom; Yang, Young-Hui; Kim, Hyo-Jin; Shin, Min-Sup; Cho, Soo-Churl; Kim, Ji-Hoon; Son, Jung-Woo; Shin, Yun-Mi; Chung, Un-Sun; Han, Doug-Hyun

    2013-06-01

    Noradrenergic dysfunction may be associated with cognitive impairments in attention-deficit/hyperactivity disorder (ADHD), including increased response time variability, which has been proposed as a leading endophenotype for ADHD. The aim of this study was to examine the relationship between polymorphisms in the α-2A-adrenergic receptor (ADRA2A) and norepinephrine transporter (SLC6A2) genes and attentional performance in ADHD children before and after pharmacological treatment.One hundred one medication-naive ADHD children were included. All subjects were administered methylphenidate (MPH)-OROS for 12 weeks. The subjects underwent a computerized comprehensive attention test to measure the response time variability at baseline before MPH treatment and after 12 weeks. Additive regression analyses controlling for ADHD symptom severity, age, sex, IQ, and final dose of MPH examined the association between response time variability on the comprehensive attention test measures and allelic variations in single-nucleotide polymorphisms of the ADRA2A and SLC6A2 before and after MPH treatment.Increasing possession of an A allele at the G1287A polymorphism of SLC6A2 was significantly related to heightened response time variability at baseline in the sustained (P = 2.0 × 10) and auditory selective attention (P = 1.0 × 10) tasks. Response time variability at baseline increased additively with possession of the T allele at the DraI polymorphism of the ADRA2A gene in the auditory selective attention task (P = 2.0 × 10). After medication, increasing possession of a G allele at the MspI polymorphism of the ADRA2A gene was associated with increased MPH-related change in response time variability in the flanker task (P = 1.0 × 10).Our study suggested an association between norepinephrine gene variants and response time variability measured at baseline and after MPH treatment in children with ADHD. Our results add to a growing body of evidence, suggesting that response time

  10. Regional changes over time in initial virological response rates to combination antiretroviral therapy across Europe

    DEFF Research Database (Denmark)

    Bannister, W; Kirk, O; Gatell, J

    2006-01-01

    BACKGROUND: Changes in virologic response to initial combination antiretroviral therapy (cART) over calendar time may indicate improvements in cART or emergence of primary resistance. Regional variations may identify differences in available antiretroviral drugs or patient management. METHODS.......026) and time (P changes were observed (south, P = 0.061; central west, P ....001; north: P = 0.070; east, P = 0.001). CONCLUSIONS: There was some evidence of regional differences in initial virologic response to cART. Improvements over time were observed, suggesting that so far, the effect of primary resistance has not been of sufficient magnitude to prevent increasing suppression...

  11. Time-dependent changes in rat lymphocyte activity in response to isolation

    International Nuclear Information System (INIS)

    Jessop, J.J.; Bayer, B.M.

    1986-01-01

    The authors have found that isolation of rats, previously adapted to group-housing conditions, resulted in time-dependent changes in mitogenic and cytolytic responses of lymphocytes. A depression (40-60%) of the uptake of 3 H-thymidine by splenic and blood lymphocytes stimulated with either phytohemagglutinin (PHA) or lipopolysaccharide (LPS) was observed during the first 48 hours after transfer of the animals to individual cages. Within 4 days the mitogenic response increased and was comparable to that of animals which had been continuously group-housed. The response continued to increase and by 10 days was enhanced by 2 to 4 fold and remained elevated for at least 8 weeks. Similar changes in activity were observed with both splenic and blood lymphocytes, however, thymic lymphocytes taken from isolated animals demonstrated no change in reactivity to PHA. As with mitogenic responses, the cytolytic activity of splenic lymphocytes was also depressed during the initial days of isolation and as isolation continued, the activity returned to normal and was significantly enhanced (80%) within 5 weeks. These data show that changes in lymphocyte activity are dependent on the duration of exposure to isolated housing conditions and may be a part of the acute, adaptive and chronic phases of the response of rats to the stress of isolation

  12. A Gravity-Responsive Time-Keeping Protein of the Plant and Animal Cell Surface

    Science.gov (United States)

    Morre, D. James

    2003-01-01

    The hypothesis under investigation was that a ubiquinol (NADH) oxidase protein of the cell surface with protein disulfide-thiol interchange activity (= NOX protein) is a plant and animal time-keeping ultradian (period of less than 24 h) driver of both cell enlargement and the biological clock that responds to gravity. Despite considerable work in a large number of laboratories spanning several decades, this is, to my knowledge, our work is the first demonstration of a time-keeping biochemical reaction that is both gravity-responsive and growth-related and that has been shown to determine circadian periodicity. As such, the NOX protein may represent both the long-sought biological gravity receptor and the core oscillator of the cellular biological clock. Completed studies have resulted in 12 publications and two issued NASA-owned patents of the clock activity. The gravity response and autoentrainment were characterized in cultured mammalian cells and in two plant systems together with entrainment by light and small molecules (melatonin). The molecular basis of the oscillatory behavior was investigated using spectroscopic methods (Fourier transform infrared and circular dichroism) and high resolution electron microscopy. We have also applied these findings to an understanding of the response to hypergravity. Statistical methods for analysis of time series phenomena were developed (Foster et al., 2003).

  13. What Are the Shapes of Response Time Distributions in Visual Search?

    Science.gov (United States)

    Palmer, Evan M.; Horowitz, Todd S.; Torralba, Antonio; Wolfe, Jeremy M.

    2011-01-01

    Many visual search experiments measure response time (RT) as their primary dependent variable. Analyses typically focus on mean (or median) RT. However, given enough data, the RT distribution can be a rich source of information. For this paper, we collected about 500 trials per cell per observer for both target-present and target-absent displays…

  14. Response Time, Visual Search Strategy, and Anticipatory Skills in Volleyball Players

    Directory of Open Access Journals (Sweden)

    Alessandro Piras

    2014-01-01

    Full Text Available This paper aimed at comparing expert and novice volleyball players in a visuomotor task using realistic stimuli. Videos of a volleyball setter performing offensive action were presented to participants, while their eye movements were recorded by a head-mounted video based eye tracker. Participants were asked to foresee the direction (forward or backward of the setter’s toss by pressing one of two keys. Key-press response time, response accuracy, and gaze behaviour were measured from the first frame showing the setter’s hand-ball contact to the button pressed by the participants. Experts were faster and more accurate in predicting the direction of the setting than novices, showing accurate predictions when they used a search strategy involving fewer fixations of longer duration, as well as spending less time in fixating all display areas from which they extract critical information for the judgment. These results are consistent with the view that superior performance in experts is due to their ability to efficiently encode domain-specific information that is relevant to the task.

  15. Time-Course Analysis of Gene Expression During the Saccharomyces cerevisiae Hypoxic Response

    Directory of Open Access Journals (Sweden)

    Nasrine Bendjilali

    2017-01-01

    Full Text Available Many cells experience hypoxia, or low oxygen, and respond by dramatically altering gene expression. In the yeast Saccharomyces cerevisiae, genes that respond are required for many oxygen-dependent cellular processes, such as respiration, biosynthesis, and redox regulation. To more fully characterize the global response to hypoxia, we exposed yeast to hypoxic conditions, extracted RNA at different times, and performed RNA sequencing (RNA-seq analysis. Time-course statistical analysis revealed hundreds of genes that changed expression by up to 550-fold. The genes responded with varying kinetics suggesting that multiple regulatory pathways are involved. We identified most known oxygen-regulated genes and also uncovered new regulated genes. Reverse transcription-quantitative PCR (RT-qPCR analysis confirmed that the lysine methyltransferase EFM6 and the recombinase DMC1, both conserved in humans, are indeed oxygen-responsive. Looking more broadly, oxygen-regulated genes participate in expected processes like respiration and lipid metabolism, but also in unexpected processes like amino acid and vitamin metabolism. Using principle component analysis, we discovered that the hypoxic response largely occurs during the first 2 hr and then a new steady-state expression state is achieved. Moreover, we show that the oxygen-dependent genes are not part of the previously described environmental stress response (ESR consisting of genes that respond to diverse types of stress. While hypoxia appears to cause a transient stress, the hypoxic response is mostly characterized by a transition to a new state of gene expression. In summary, our results reveal that hypoxia causes widespread and complex changes in gene expression to prepare the cell to function with little or no oxygen.

  16. Time-Course Analysis of Gene Expression During the Saccharomyces cerevisiae Hypoxic Response.

    Science.gov (United States)

    Bendjilali, Nasrine; MacLeon, Samuel; Kalra, Gurmannat; Willis, Stephen D; Hossian, A K M Nawshad; Avery, Erica; Wojtowicz, Olivia; Hickman, Mark J

    2017-01-05

    Many cells experience hypoxia, or low oxygen, and respond by dramatically altering gene expression. In the yeast Saccharomyces cerevisiae, genes that respond are required for many oxygen-dependent cellular processes, such as respiration, biosynthesis, and redox regulation. To more fully characterize the global response to hypoxia, we exposed yeast to hypoxic conditions, extracted RNA at different times, and performed RNA sequencing (RNA-seq) analysis. Time-course statistical analysis revealed hundreds of genes that changed expression by up to 550-fold. The genes responded with varying kinetics suggesting that multiple regulatory pathways are involved. We identified most known oxygen-regulated genes and also uncovered new regulated genes. Reverse transcription-quantitative PCR (RT-qPCR) analysis confirmed that the lysine methyltransferase EFM6 and the recombinase DMC1, both conserved in humans, are indeed oxygen-responsive. Looking more broadly, oxygen-regulated genes participate in expected processes like respiration and lipid metabolism, but also in unexpected processes like amino acid and vitamin metabolism. Using principle component analysis, we discovered that the hypoxic response largely occurs during the first 2 hr and then a new steady-state expression state is achieved. Moreover, we show that the oxygen-dependent genes are not part of the previously described environmental stress response (ESR) consisting of genes that respond to diverse types of stress. While hypoxia appears to cause a transient stress, the hypoxic response is mostly characterized by a transition to a new state of gene expression. In summary, our results reveal that hypoxia causes widespread and complex changes in gene expression to prepare the cell to function with little or no oxygen. Copyright © 2017 Bendjilali et al.

  17. Aggregate modeling of fast-acting demand response and control under real-time pricing

    International Nuclear Information System (INIS)

    Chassin, David P.; Rondeau, Daniel

    2016-01-01

    Highlights: • Demand elasticity for fast-acting demand response load under real-time pricing. • Validated first-principles logistic demand curve matches random utility model. • Logistic demand curve suitable for diversified aggregate loads market-based transactive control systems. - Abstract: This paper develops and assesses the performance of a short-term demand response (DR) model for utility load control with applications to resource planning and control design. Long term response models tend to underestimate short-term demand response when induced by prices. This has two important consequences. First, planning studies tend to undervalue DR and often overlook its benefits in utility demand management program development. Second, when DR is not overlooked, the open-loop DR control gain estimate may be too low. This can result in overuse of load resources, control instability and excessive price volatility. Our objective is therefore to develop a more accurate and better performing short-term demand response model. We construct the model from first principles about the nature of thermostatic load control and show that the resulting formulation corresponds exactly to the Random Utility Model employed in economics to study consumer choice. The model is tested against empirical data collected from field demonstration projects and is shown to perform better than alternative models commonly used to forecast demand in normal operating conditions. The results suggest that (1) existing utility tariffs appear to be inadequate to incentivize demand response, particularly in the presence of high renewables, and (2) existing load control systems run the risk of becoming unstable if utilities close the loop on real-time prices.

  18. Enhanced Interrupt Response Time in the nMPRA based on Embedded Real Time Microcontrollers

    Directory of Open Access Journals (Sweden)

    GAITAN, N. C.

    2017-08-01

    Full Text Available In any real-time operating system, task switching and scheduling, interrupts, synchronization and communication between processes, represent major problems. The implementation of these mechanisms through software generates significant delays for many applications. The nMPRA (Multi Pipeline Register Architecture architecture is designed for the implementation of real-time embedded microcontrollers. It supports the competitive execution of n tasks, enabling very fast switching between them, with a usual delay of one machine cycle and a maximum of 3 machine cycles, for the memory-related work instructions. This is because each task has its own PC (Program Counter, set of pipeline registers and a general registers file. The nMPRA is provided with an advanced distributed interrupt controller that implements the concept of "interrupts as threads". This allows the attachment of one or more interrupts to the same task. In this context, the original contribution of this article is to presents the solutions for improving the response time to interrupts when a task has attached a large number of interrupts. The proposed solutions enhance the original architecture for interrupts logic in order to transfer control, to the interrupt handler as soon as possible, and to create an interrupt prioritization at task level.

  19. Organic scintillators response function modeling for Monte Carlo simulation of Time-of-Flight measurements

    Energy Technology Data Exchange (ETDEWEB)

    Carasco, C., E-mail: cedric.carasco@cea.fr [CEA, DEN, Cadarache, Nuclear Measurement Laboratory, F-13108 Saint-Paul-lez-Durance (France)

    2012-07-15

    In neutron Time-of-Flight (TOF) measurements performed with fast organic scintillation detectors, both pulse arrival time and amplitude are relevant. Monte Carlo simulation can be used to calculate the time-energy dependant neutron flux at the detector position. To convert the flux into a pulse height spectrum, one must calculate the detector response function for mono-energetic neutrons. MCNP can be used to design TOF systems, but standard MCNP versions cannot reliably calculate the energy deposited by fast neutrons in the detector since multiple scattering effects must be taken into account in an analog way, the individual recoil particles energy deposit being summed with the appropriate scintillation efficiency. In this paper, the energy response function of 2 Double-Prime Multiplication-Sign 2 Double-Prime and 5 Double-Prime Multiplication-Sign 5 Double-Prime liquid scintillation BC-501 A (Bicron) detectors to fast neutrons ranging from 20 keV to 5.0 MeV is computed with GEANT4 to be coupled with MCNPX through the 'MCNP Output Data Analysis' software developed under ROOT (). - Highlights: Black-Right-Pointing-Pointer GEANT4 has been used to model organic scintillators response to neutrons up to 5 MeV. Black-Right-Pointing-Pointer The response of 2 Double-Prime Multiplication-Sign 2 Double-Prime and 5 Double-Prime Multiplication-Sign 5 Double-Prime BC501A detectors has been parameterized with simple functions. Black-Right-Pointing-Pointer Parameterization will allow the modeling of neutron Time of Flight measurements with MCNP using tools based on CERN's ROOT.

  20. Combined Characterization of the Time Response of Impression Materials via Traditional and FTIR Measurements

    Directory of Open Access Journals (Sweden)

    Giacomo Derchi

    2015-05-01

    Full Text Available We investigated the temporal response of four dental impression materials, namely three siloxanes (Imprint 4, Flexitime, Aquasil and one polyether (Impregum. The null hypothesis was that the nominal working times are confirmed by instrumental laboratory tests. We also aimed to identify alternative techniques with strong physical-chemical background for the assessment of temporal response. Traditional characterization was carried out by shark fin test device and durometer at both ambient and body temperature. Additionally, Fourier-transform infrared spectroscopy was performed at room temperature. From shark fin height and Shore hardness versus time the working time and the setting time of the materials were evaluated, respectively. These were in reasonable agreement with the nominal values, except for Impregum, which showed longer working time. Spectroscopy confirmed the different character of the two types of materials, and provided for Imprint 4 and Aquasil an independent evaluation of both evolution times, consistent with the results of the other techniques. Shark fin test and durometer measurements showed deviations in setting time, low sensitivity to temperature for Flexitime, and longer working time at higher temperature for Impregum. Deviations of working time appear in operating conditions from what specified by the manufacturers. Fourier-transform infrared spectroscopy can provide insight in the correlation between material properties and their composition and structure.

  1. QUERY RESPONSE TIME COMPARISON NOSQLDB MONGODB WITH SQLDB ORACLE

    Directory of Open Access Journals (Sweden)

    Humasak T. A. Simanjuntak

    2015-01-01

    Full Text Available Penyimpanan data saat ini terdapat dua jenis yakni relational database dan non-relational database. Kedua jenis DBMS (Database Managemnet System tersebut berbeda dalam berbagai aspek seperti per-formansi eksekusi query, scalability, reliability maupun struktur penyimpanan data. Kajian ini memiliki tujuan untuk mengetahui perbandingan performansi DBMS antara Oracle sebagai jenis relational data-base dan MongoDB sebagai jenis non-relational database dalam mengolah data terstruktur. Eksperimen dilakukan untuk mengetahui perbandingan performansi kedua DBMS tersebut untuk operasi insert, select, update dan delete dengan menggunakan query sederhana maupun kompleks pada database Northwind. Untuk mencapai tujuan eksperimen, 18 query yang terdiri dari 2 insert query, 10 select query, 2 update query dan 2 delete query dieksekusi. Query dieksekusi melalui sebuah aplikasi .Net yang dibangun sebagai perantara antara user dengan basis data. Eksperimen dilakukan pada tabel dengan atau tanpa relasi pada Oracle dan embedded atau bukan embedded dokumen pada MongoDB. Response time untuk setiap eksekusi query dibandingkan dengan menggunakan metode statistik. Eksperimen menunjukkan response time query untuk proses select, insert, dan update pada MongoDB lebih cepatdaripada Oracle. MongoDB lebih cepat 64.8 % untuk select query;MongoDB lebihcepat 72.8 % untuk insert query dan MongoDB lebih cepat 33.9 % untuk update query. Pada delete query, Oracle lebih cepat 96.8 % daripada MongoDB untuk table yang berelasi, tetapi MongoDB lebih cepat 83.8 % daripada Oracle untuk table yang tidak memiliki relasi.Untuk query kompleks dengan Map Reduce pada MongoDB lebih lambat 97.6% daripada kompleks query dengan aggregate function pada Oracle.

  2. A time-frequency analysis method to obtain stable estimates of magnetotelluric response function based on Hilbert-Huang transform

    Science.gov (United States)

    Cai, Jianhua

    2017-05-01

    The time-frequency analysis method represents signal as a function of time and frequency, and it is considered a powerful tool for handling arbitrary non-stationary time series by using instantaneous frequency and instantaneous amplitude. It also provides a possible alternative to the analysis of the non-stationary magnetotelluric (MT) signal. Based on the Hilbert-Huang transform (HHT), a time-frequency analysis method is proposed to obtain stable estimates of the magnetotelluric response function. In contrast to conventional methods, the response function estimation is performed in the time-frequency domain using instantaneous spectra rather than in the frequency domain, which allows for imaging the response parameter content as a function of time and frequency. The theory of the method is presented and the mathematical model and calculation procedure, which are used to estimate response function based on HHT time-frequency spectrum, are discussed. To evaluate the results, response function estimates are compared with estimates from a standard MT data processing method based on the Fourier transform. All results show that apparent resistivities and phases, which are calculated from the HHT time-frequency method, are generally more stable and reliable than those determined from the simple Fourier analysis. The proposed method overcomes the drawbacks of the traditional Fourier methods, and the resulting parameter minimises the estimation bias caused by the non-stationary characteristics of the MT data.

  3. Real Time Optimal Control of Supercapacitor Operation for Frequency Response

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Yusheng; Panwar, Mayank; Mohanpurkar, Manish; Hovsapian, Rob

    2016-07-01

    Supercapacitors are gaining wider applications in power systems due to fast dynamic response. Utilizing supercapacitors by means of power electronics interfaces for power compensation is a proven effective technique. For applications such as requency restoration if the cost of supercapacitors maintenance as well as the energy loss on the power electronics interfaces are addressed. It is infeasible to use traditional optimization control methods to mitigate the impacts of frequent cycling. This paper proposes a Front End Controller (FEC) using Generalized Predictive Control featuring real time receding optimization. The optimization constraints are based on cost and thermal management to enhance to the utilization efficiency of supercapacitors. A rigorous mathematical derivation is conducted and test results acquired from Digital Real Time Simulator are provided to demonstrate effectiveness.

  4. Prospective Trial of House Staff Time to Response and Intervention in a Surgical Intensive Care Unit: Pager vs. Smartphone.

    Science.gov (United States)

    Tatum, James M; White, Terris; Kang, Christopher; Ley, Eric J; Melo, Nicolas; Bloom, Matthew; Alban, Rodrigo F

    The objective of the study was to characterize house staff time to response and intervention when notified of a patient care issue by pager vs. smartphone. We hypothesized that smartphones would reduce house staff time to response and intervention. Prospective study of all electronic communications was conducted between nurses and house staff between September 2015 and October 2015. The 4-week study period was randomly divided into two 2-week study periods where all electronic communications between intensive care unit nurses and intensive care unit house staff were exclusively by smartphone or by pager, respectively. Time of communication initiation, time of house staff response, and time from response to clinical intervention for each communication were recorded. Outcomes are time from nurse contact to house staff response and intervention. Single-center surgical intensive care unit of Cedars-Sinai Medical Center in Los Angeles, California, an academic tertiary care and level I trauma center. All electronic communications occurring between nurses and house staff in the study unit during the study period were considered. During the study period, 205 nurse-house staff electronic communications occurred, 100 in the phone group and 105 in the pager group. House staff response to communication time was significantly shorter in the phone group (0.5 [interquartile range = 1.7] vs. 2 [3]min, p house staff intervention after response was also significantly more rapid in the phone group (0.8 [1.7] vs. 1 [2]min, p = 0.003). Dedicated clinical smartphones significantly decrease time to house staff response after electronic nursing communications compared with pagers. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  5. Stimulus-response time to alarms of the intra-aortic balloon pump: safe care practices

    Directory of Open Access Journals (Sweden)

    Andrezza Serpa Franco

    Full Text Available ABSTRACT Objective: To characterize the sound alarms of the Intra-Aortic Balloon Pump (IABP during aortic counterpulsation therapy; to measure the stimulus-response time of the team to these; and to discuss the implications of increasing this time for patient safety from the alarm fatigue perspective. Method: This is an observational and descriptive study with quantitative and qualitative approach, case study type, carried out in a Cardiac Surgical Intensive Care Unit. Results: The most audible IABP alarm was the one of high priority increased-reduced diastolic blood pressure. The stimulus-response time was 33.9 seconds on average. Conclusion: Managing the alarms of these equipment is essential to minimize the occurrence of the alarm fatigue phenomenon and to offer a safer assistance to patients who rely on this technology.

  6. Effect of processing time delay on the dose response of Kodak EDR2 film.

    Science.gov (United States)

    Childress, Nathan L; Rosen, Isaac I

    2004-08-01

    Kodak EDR2 film is a widely used two-dimensional dosimeter for intensity modulated radiotherapy (IMRT) measurements. Our clinical use of EDR2 film for IMRT verifications revealed variations and uncertainties in dose response that were larger than expected, given that we perform film calibrations for every experimental measurement. We found that the length of time between film exposure and processing can affect the absolute dose response of EDR2 film by as much as 4%-6%. EDR2 films were exposed to 300 cGy using 6 and 18 MV 10 x 10 cm2 fields and then processed after time delays ranging from 2 min to 24 h. An ion chamber measured the relative dose for these film exposures. The ratio of optical density (OD) to dose stabilized after 3 h. Compared to its stable value, the film response was 4%-6% lower at 2 min and 1% lower at 1 h. The results of the 4 min and 1 h processing time delays were verified with a total of four different EDR2 film batches. The OD/dose response for XV2 films was consistent for time periods of 4 min and 1 h between exposure and processing. To investigate possible interactions of the processing time delay effect with dose, single EDR2 films were irradiated to eight different dose levels between 45 and 330 cGy using smaller 3 x 3 cm2 areas. These films were processed after time delays of 1, 3, and 6 h, using 6 and 18 MV photon qualities. The results at all dose levels were consistent, indicating that there is no change in the processing time delay effect for different doses. The difference in the time delay effect between the 6 and 18 MV measurements was negligible for all experiments. To rule out bias in selecting film regions for OD measurement, we compared the use of a specialized algorithm that systematically determines regions of interest inside the 10 x 10 cm2 exposure areas to manually selected regions of interest. There was a maximum difference of only 0.07% between the manually and automatically selected regions, indicating that the use of

  7. Enhanced responses to tumor immunization following total body irradiation are time-dependent.

    Directory of Open Access Journals (Sweden)

    Adi Diab

    Full Text Available The development of successful cancer vaccines is contingent on the ability to induce effective and persistent anti-tumor immunity against self-antigens that do not typically elicit immune responses. In this study, we examine the effects of a non-myeloablative dose of total body irradiation on the ability of tumor-naïve mice to respond to DNA vaccines against melanoma. We demonstrate that irradiation followed by lymphocyte infusion results in a dramatic increase in responsiveness to tumor vaccination, with augmentation of T cell responses to tumor antigens and tumor eradication. In irradiated mice, infused CD8(+ T cells expand in an environment that is relatively depleted in regulatory T cells, and this correlates with improved CD8(+ T cell functionality. We also observe an increase in the frequency of dendritic cells displaying an activated phenotype within lymphoid organs in the first 24 hours after irradiation. Intriguingly, both the relative decrease in regulatory T cells and increase in activated dendritic cells correspond with a brief window of augmented responsiveness to immunization. After this 24 hour window, the numbers of dendritic cells decline, as does the ability of mice to respond to immunizations. When immunizations are initiated within the period of augmented dendritic cell activation, mice develop anti-tumor responses that show increased durability as well as magnitude, and this approach leads to improved survival in experiments with mice bearing established tumors as well as in a spontaneous melanoma model. We conclude that irradiation can produce potent immune adjuvant effects independent of its ability to induce tumor ablation, and that the timing of immunization and lymphocyte infusion in the irradiated host are crucial for generating optimal anti-tumor immunity. Clinical strategies using these approaches must therefore optimize such parameters, as the correct timing of infusion and vaccination may mean the difference

  8. Response time verification of in situ hydraulic pressure sensors in a nuclear reactor

    International Nuclear Information System (INIS)

    Foster, C.G.

    1978-01-01

    A method and apparatus for verifying response time in situ of hydraulic pressure and pressure differential sensing instrumentation in a nuclear circuit is disclosed. Hydraulic pressure at a reference sensor and at an in situ process sensor under test is varied according to a linear ramp. Sensor response time is then determined by comparison of the sensor electrical analog output signals. The process sensor is subjected to a relatively slowly changing and a relatively rapidly changing hydraulic pressure ramp signal to determine an upper bound for process sensor response time over the range of all pressure transients to which the sensor is required to respond. Signal linearity is independent of the volumetric displacement of the process sensor. The hydraulic signal generator includes a first pressurizable gas reservoir, a second pressurizable liquid and gas reservoir, a gate for rapidly opening a gas communication path between the two reservoirs, a throttle valve for regulating rate of gas pressure equalization between the two reservoirs, and hydraulic conduit means for simultaneously communicating a ramp of hydraulic pressure change between the liquid/gas reservoir and both a reference and a process sensor. By maintaining a sufficient pressure differential between the reservoirs and by maintaining a sufficient ratio of gas to liquid in the liquid/gas reservoir, excellent linearity and minimal transient effects can be achieved for all pressure ranges, magnitudes, and rates of change of interest

  9. Physiological demands of women's rugby union: time-motion analysis and heart rate response.

    Science.gov (United States)

    Virr, Jody Lynn; Game, Alex; Bell, Gordon John; Syrotuik, Daniel

    2014-01-01

    The aim of this study was to determine the physical demands of women's rugby union match play using time-motion analysis and heart rate (HR) response. Thirty-eight premier club level female rugby players, ages 18-34 years were videotaped and HRs monitored for a full match. Performances were coded into 12 different movement categories: 5 speeds of locomotion (standing, walking, jogging, striding, sprinting), 4 forms of intensive non-running exertion (ruck/maul/tackle, pack down, scrum, lift) and 3 discrete activities (kick, jump, open field tackle). The main results revealed that backs spend significantly more time sprinting and walking whereas forwards spend more time in intensive non-running exertion and jogging. Forwards also had a significantly higher total work frequency compared to the backs, but a higher total rest frequency compared to the backs. In terms of HR responses, forwards displayed higher mean HRs throughout the match and more time above 80% of their maximum HR than backs. In summary, women's rugby union is characterised by intermittent bursts of high-intensity activity, where forwards and backs have similar anaerobic energy demands, but different specific match demands.

  10. Stepped-Wedge Cluster Randomized Controlled Trial to Promote Option B+ Retention in Central Mozambique.

    Science.gov (United States)

    Pfeiffer, James T; Napúa, Manuel; Wagenaar, Bradley H; Chale, Falume; Hoek, Roxanne; Micek, Mark; Manuel, João; Michel, Cathy; Cowan, Jessica Greenberg; Cowan, James F; Gimbel, Sarah; Sherr, Kenneth; Gloyd, Stephen; Chapman, Rachel R

    2017-11-01

    This randomized trial studied performance of Option B+ in Mozambique and evaluated an enhanced retention package in public clinics. The study was conducted at 6 clinics in Manica and Sofala Provinces in central Mozambique. Seven hundred sixty-one pregnant women tested HIV+, immediately initiated antiretroviral (ARV) therapy, and were followed to track retention at 6 clinics from May 2014 to May 2015. Clinics were randomly allocated within a stepped-wedge fashion to intervention and control periods. The intervention included (1) workflow modifications and (2) active patient tracking. Retention was defined as percentage of patients returning for 30-, 60-, and 90-day medication refills within 25-35 days of previous refills. During control periods, 52.3% of women returned for 30-day refills vs. 70.8% in intervention periods [odds ratio (OR): 1.80; 95% confidence interval (CI): 1.05 to 3.08]. At 60 days, 46.1% control vs. 57.9% intervention were retained (OR: 1.82; CI: 1.06 to 3.11), and at 90 days, 38.3% control vs. 41.0% intervention (OR: 1.04; CI: 0.60 to 1.82). In prespecified subanalyses, birth before pickups was strongly associated with failure-women giving birth before ARV pickup were 33.3 times (CI: 4.4 to 250.3), 7.5 times (CI: 3.6 to 15.9), and 3.7 times (CI: 2.2 to 6.0) as likely to not return for ARV pickups at 30, 60, and 90 days, respectively. The intervention was effective at 30 and 60 days, but not at 90 days. Combined 90-day retention (40%) and adherence (22.5%) were low. Efforts to improve retention are particularly important for women giving birth before ARV refills.

  11. Early Flood Detection for Rapid Humanitarian Response: Harnessing Near Real-Time Satellite and Twitter Signals

    Directory of Open Access Journals (Sweden)

    Brenden Jongman

    2015-10-01

    Full Text Available Humanitarian organizations have a crucial role in response and relief efforts after floods. The effectiveness of disaster response is contingent on accurate and timely information regarding the location, timing and impacts of the event. Here we show how two near-real-time data sources, satellite observations of water coverage and flood-related social media activity from Twitter, can be used to support rapid disaster response, using case-studies in the Philippines and Pakistan. For these countries we analyze information from disaster response organizations, the Global Flood Detection System (GFDS satellite flood signal, and flood-related Twitter activity analysis. The results demonstrate that these sources of near-real-time information can be used to gain a quicker understanding of the location, the timing, as well as the causes and impacts of floods. In terms of location, we produce daily impact maps based on both satellite information and social media, which can dynamically and rapidly outline the affected area during a disaster. In terms of timing, the results show that GFDS and/or Twitter signals flagging ongoing or upcoming flooding are regularly available one to several days before the event was reported to humanitarian organizations. In terms of event understanding, we show that both GFDS and social media can be used to detect and understand unexpected or controversial flood events, for example due to the sudden opening of hydropower dams or the breaching of flood protection. The performance of the GFDS and Twitter data for early detection and location mapping is mixed, depending on specific hydrological circumstances (GFDS and social media penetration (Twitter. Further research is needed to improve the interpretation of the GFDS signal in different situations, and to improve the pre-processing of social media data for operational use.

  12. Does the brake response time of the right leg change after left total knee arthroplasty? A prospective study.

    Science.gov (United States)

    Marques, Carlos J; Barreiros, João; Cabri, Jan; Carita, Ana I; Friesecke, Christian; Loehr, Jochen F

    2008-08-01

    Patients undergoing total knee arthroplasty often ask when they can safely resume car driving. There is little evidence available on which physicians can rely when advising patients on this issue. In a prospective study we assessed the brake response time of 24 patients admitted to the clinic for left total knee arthroplasty preoperatively and then 10 days after surgery. On each measurement day the patients performed two tasks, a simple and a complex brake response time task in a car simulator. Ten days after left TKA the brake response time for the simple task had decreased by 3.6% (p=0.24), the reaction time by 3.1% (p=0.34) and the movement time by 6.6% (p=0.07). However, the performance improvement was not statistically significant. Task complexity increased brake response time at both time points. A 5.8% increase was significant (p=0.01) at 10 days after surgery. Based on our results, we suggest that patients who have undergone left total knee arthroplasty may resume car driving 10 days after surgery as long as they drive a car with automatic transmission.

  13. Optical Response of Warm Dense Matter Using Real-Time Electron Dynamics

    Science.gov (United States)

    Baczewski, Andrew; Shulenburger, Luke; Desjarlais, Michael; Magyar, Rudolph

    2014-03-01

    The extreme temperatures and solid-like densities in warm dense matter present a unique challenge for theory, wherein neither conventional models from condensed matter nor plasma physics capture all of the relevant phenomenology. While Kubo-Greenwood DFT calculations have proven capable of reproducing optical properties of WDM, they require a significant number of virtual orbitals to reach convergence due to their perturbative nature. Real-time TDDFT presents a complementary framework with a number of computationally favorable properties, including reduced cost complexity and better scalability, and has been used to reproduce the optical response of finite and ordered extended systems. We will describe the use of Ehrenfest-TDDFT to evolve coupled electron-nuclear dynamics in WDM systems, and the subsequent evaluation of optical response functions from the real-time electron dynamics. The advantages and disadvantages of this approach will be discussed relative to the current state-of-the-art. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Security Administration under contract DE-AC04-94AL85000.

  14. A hydrogen refill for cellular phone

    Science.gov (United States)

    Prosini, Pier Paolo; Gislon, Paola

    A device has been designed to generate hydrogen for a fuel cell powered cellular phone. The device is based on the chemical reaction between NaBH 4 and hydrochloric/water solution to satisfy the hydrogen request at room temperature and pressure. The operation mechanism and controlling method is based on the Kipp's gas generating apparatus. A prototype has been built and tested to evaluate the optimum salt/acid and acid/solution ratios and check the hydrogen mass flow rates upon operation and the pressure variation in stand-by condition. The system works delivering hydrogen flows ranging between 0 and 10 ml min -1. In a typical test the hydrogen flow was set to 5 ml min -1 to match a 1 W power fuel cell. The working pressure was slightly higher than the atmospheric one. The hydrogen capacity was as high as 2.5% (w/w). By converting this amount of hydrogen in electricity by a fuel cell working at 0.8 V it is possible to achieve a system energy density of about 720 Wh kg -1, four times larger than commercial high energy density lithium-ion batteries.

  15. On timing response improvement of an NE213 scintillator attached to two PMTs

    International Nuclear Information System (INIS)

    Zare, S.; Ghal-Eh, N.; Bayat, E.

    2013-01-01

    A 5 cm diameter by 6 cm height NE213 scintillator attached to two XP2282 PHOTONIS photomultiplier tubes (PMTs) exposed to 241 Americium–Berylium (Am–Be) neutron–gamma source has been used for timing response studies. The neutron–gamma discrimination (NGD) measurements based on a modified zero-crossing (ZC) method show that the discrimination quality, usually expressed in figure-of-merit (FoM) and peak-to-valley (P/V) values, has been improved. The timing response evaluated with Monte Carlo light transport code, PHOTRACK, also verifies this improvement. - Highlights: • An NE213 scintillator attached to two photomultiplier tubes (PMTs) has been proposed. • The neutron–gamma discrimination (NGD) quality factors have been obtained. • The results confirm that the NGD quality of the proposed assembly has been improved

  16. PKL/K9, Refill and Reflood Experiment in a Simulated PWR Primary System (PKL)

    International Nuclear Information System (INIS)

    1981-01-01

    1 - Description of test facility: PKL-facility simulates the essential primary system components of a typical West German 1300 PWR with regard to their thermohydraulic behaviour. The facility essentially consists of the pressure vessel with the heated bundle, the downcomer simulator, the primary loops with the components steam generator and pump simulator, the injection devices, the break geometry simulator, as well as the separators connected thereto, and the test containment to maintain a back-pressure at the location of break which is expected to be typical for emergency conditions. The number of heater rods and the cross-sections of the testing plant are on a reduced scale 1:134 in comparison with a typical German PWR. The elevations and locations are essentially full scale. Pressure vessel: The space between the pressure vessel and the inner core casing is sealed from the core region and the upper and lower plenum and connected with the upper plenum only by a pressure equalization line. The rod bundle surrounded by the inner core casing consists of 340 rods, 337 of which are indirect electrically heated. The test bundle cross-section as well as a heater element with the measuring elevations, the original-KWU-spacers and the axial power profile (7 power steps) are described. Downcomer: The downcomer is simulated by the downcomer nozzle region and the downcomer U-tube. The cold leg injection takes place both directly in the downcomer nozzle region and in the lines of t he intact single and double loop near to the downcomer nozzle region. A cylindrical insertion and repulsing metal sheets are installed in the downcomer nozzle region in order to avoid the emergency injection points into the broken loop. 2 - Description of test: Test K 9 out of a series PKL-IB was conducted on May 30, 1979 by Kraftwerk Union (KWU) at Erlangen (Germany). The objective of the integral cold leg injection test K 9 (double-ended 200%-break) was to investigate after a LOCA the refill and

  17. The role of elevated central-peripheral temperature difference in early detection of late-onset sepsis in preterm infants.

    Science.gov (United States)

    Ussat, M; Vogtmann, C; Gebauer, C; Pulzer, F; Thome, U; Knüpfer, M

    2015-12-01

    The study investigated the association between clinical symptoms and late-onset sepsis (LOS) in preterm infants with the aim of identifying a non-invasive tool for the early detection of LOS. This was a prospective study of 83 episodes of suspected LOS in 67 preterm infants. At the time LOS was suspected, we recorded a standardized set of clinical symptoms. A diagnosis of "clinical LOS" (Clin-LOS), "culture-proven LOS" (Prov-LOS) or "LOS not present" (No-LOS) was made on the basis of C-reactive protein (CrP) and blood culture results where Clin-LOS was defined as CrP>10mg/l, Prov-LOS was defined as CrP>10mg/l AND positive blood cultures, or it was established that there was no sepsis present (No-LOS). We examined univariable associations between clinical signs and LOS using odds ratio (OR) analysis and then adjusted the odds ratio (adOR) through binary regression analysis. Clin-LOS was diagnosed in 20/83 episodes, 19 cases were found to have Prov-LOS. Clinical signs which had a significant association with Clin-LOS were capillary refill time >2s (OR 2.9) and decreased responsiveness (OR 5.2), whereas there was a negative association between gastric residuals and LOS (OR 0.35). However, the most marked association was found for a greater central-peripheral temperature difference (cpTD) >2°C (OR 9). In Prov-LOS an increased heart rate (OR 3.1), prolonged capillary refill time (OR 3.3) and again an increased cpTD (OR 16) had a significant association with LOS, whereas gastric residuals were negatively associated (OR 0.29). Regression analysis showed that cpTD was the most striking clinical sign associated with both Clin- (adOR 6.3) and Prov-LOS (adOR 10.5). Prolonged capillary refill time and - more impressive - elevated cpTD were the most useful clinical symptoms for detection of LOS in preterm infants. We especially suggest using cpTD as a predictor of LOS. It is a cheap, non-invasive and readily available tool for daily routines. Copyright © 2015. Published by

  18. Psychophysics in a Web browser? Comparing response times collected with JavaScript and Psychophysics Toolbox in a visual search task.

    Science.gov (United States)

    de Leeuw, Joshua R; Motz, Benjamin A

    2016-03-01

    Behavioral researchers are increasingly using Web-based software such as JavaScript to conduct response time experiments. Although there has been some research on the accuracy and reliability of response time measurements collected using JavaScript, it remains unclear how well this method performs relative to standard laboratory software in psychologically relevant experimental manipulations. Here we present results from a visual search experiment in which we measured response time distributions with both Psychophysics Toolbox (PTB) and JavaScript. We developed a methodology that allowed us to simultaneously run the visual search experiment with both systems, interleaving trials between two independent computers, thus minimizing the effects of factors other than the experimental software. The response times measured by JavaScript were approximately 25 ms longer than those measured by PTB. However, we found no reliable difference in the variability of the distributions related to the software, and both software packages were equally sensitive to changes in the response times as a result of the experimental manipulations. We concluded that JavaScript is a suitable tool for measuring response times in behavioral research.

  19. Dose-response model of murine typhus (Rickettsia typhi: time post inoculation and host age dependency analysis

    Directory of Open Access Journals (Sweden)

    Tamrakar Sushil B

    2012-03-01

    Full Text Available Abstract Background Rickettsia typhi (R. mooseri is the causative agent of murine typhus. It is one of the most widely distributed flea-borne diseases with a relatively mild febrile initial illness with six to 14 days of incubation period. The bacterium is gram negative and an obligate intracellular pathogen. The disease is transmitted to humans and vertebrate host through fleabites or via contact with infected feces. This paper develops dose-response models of different routes of exposure for typhus in rodents. Methods Data from published articles were analyzed using parametric dose-response relationship models. Dose-response relationships were fit to data using the method of maximum likelihood estimation (MLE. Results Dose-response models quantifying the effects of different ages of rats and time post inoculation in BALB/c mice were analyzed in the study. Both the adult rats (inoculated intradermally and newborn rats (inoculated subcutaneously were best fit by exponential models and both distributions could be described by a single dose-response relationship. The BALB/C mice inoculated subcutaneously were best fit by Beta-Poisson models. The time post inoculation analysis showed that there was a definite time and response relationship existed in this case. Conclusions Intradermally or subcutaneously inoculated rats (adult and newborn models suggest that less than 1 plaque-forming unit (PFU (1.33 to 0.38 in 95% confidence limits of the pathogen is enough to seroconvert 50% of the exposed population on average. For the BALB/c mouse time post inoculation model, an average dose of 0.28 plaque-forming units (PFU (0.75 to 0.11 in 95% confidence limits will seroconvert 50% of the exposed mice.

  20. Time response model of ER fluids for precision control of motors

    Energy Technology Data Exchange (ETDEWEB)

    Koyanagi, Ken' ichi [Toyama Prefectural University, 5180 Kurokawa, Imizu, Toyama (Japan)], E-mail: koyanagi@pu-toyama.ac.jp

    2009-02-01

    For improvement of control performance or new control demands of mechatronics devices using particle type ER fluids, it will be needed to further investigate a response time of the fluids. It is commonly said around 5-mili seconds, however, the formula structure of that delay has not been clear. This study aims to develop a functional damper (attenuators), that can control its viscous characteristics in real time using ER fluids as its working fluid. ER dampers are useful to accomplish high precision positioning not to prevent high speed movement of the motor. To realize the functional damper that can be manipulated according to situations or tasks, the modeling and control of ER fluids are necessary. This paper investigates time delay affects of ER fluids and makes an in-depth dynamic model of the fluid by utilizing simulation and experiment. The mathematical model has a dead-time and first ordered delays of the fluid and the high voltage amplifier for the fluid.

  1. Water Storage, Mixing and Transit Times During a Multiyear Drought.

    Science.gov (United States)

    Van der Velde, Y.; Visser, A.; Thaw, M.; Safeeq, M.

    2017-12-01

    From 2012 to 2016, a five year intensive drought occurred in the Californian Sierra Nevada. We use this drought period as an opportunity to investigate how catchment water storage, mixing and transit times changes from wet to dry conditions using long term datasets of river discharge, evapotranspiration, water quality, and multiple cosmogenic radioactive isotopes. Characteristic features of the test catchment (4.6 km2 , altitude 1660-2117 m) include a thick (>5m) unsaturated zone in deeply weathered granite mountain soils, snow melt and events of high intensity rainfall, dry summers and numerous wetland meadows along the stream. Our data and model analysis suggest that under drought conditions, river flow predominantly consist of deep groundwater tapped by deeply incised sections of the stream, while the wetlands hold on to their water just below the root system of its shallow rooting vegetation. In contrast, during wet periods, most runoff is generated on the flat riparian wetland meadows, while the regional groundwater system slowly refills itself as water makes its way through the thick unsaturated zones. Antecedent wet or dry years play an crucial role as antecedent wet years cause a substantial regional groundwater flow towards the riparian wetlands, filling up the riparian wetlands and yielding a much stronger discharge response of the wetlands to rainfall events than under antecedent dry years This interaction between the regional groundwater system and the local wetland systems weakens as the drought progresses and regional groundwater flow to the wetlands lessens. Although, due to the wet events in 2016-2017, the catchment fills up rapidly to pre-drought conditions, we show that water transit times and therefore likely the water quality will contain drought signs for several years to come. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. LLNL-ABS- XXXXXX

  2. Study on deterministic response time design for a class of nuclear Instrumentation and Control systems

    International Nuclear Information System (INIS)

    Chen, Chang-Kuo; Hou, Yi-You; Luo, Cheng-Long

    2012-01-01

    Highlights: ► An efficient design procedure for deterministic response time design of nuclear I and C system. ► We model the concurrent operations based on sequence diagrams and Petri nets. ► The model can achieve the deterministic behavior by using symbolic time representation. ► An illustrative example of the bistable processor logic is given. - Abstract: This study is concerned with a deterministic response time design for computer-based systems in the nuclear industry. In current approach, Petri nets are used to model the requirement of a system specified with sequence diagrams. Also, the linear logic is proposed to characterize the state of changes in the Petri net model accurately by using symbolic time representation for the purpose of acquiring deterministic behavior. An illustrative example of the bistable processor logic is provided to demonstrate the practicability of the proposed approach.

  3. Additive and Interactive Effects on Response Time Distributions in Visual Word Recognition

    Science.gov (United States)

    Yap, Melvin J.; Balota, David A.

    2007-01-01

    Across 3 different word recognition tasks, distributional analyses were used to examine the joint effects of stimulus quality and word frequency on underlying response time distributions. Consistent with the extant literature, stimulus quality and word frequency produced additive effects in lexical decision, not only in the means but also in the…

  4. Decision-Tree Models of Categorization Response Times, Choice Proportions, and Typicality Judgments

    Science.gov (United States)

    Lafond, Daniel; Lacouture, Yves; Cohen, Andrew L.

    2009-01-01

    The authors present 3 decision-tree models of categorization adapted from T. Trabasso, H. Rollins, and E. Shaughnessy (1971) and use them to provide a quantitative account of categorization response times, choice proportions, and typicality judgments at the individual-participant level. In Experiment 1, the decision-tree models were fit to…

  5. Experimental study of a SINIS detector response time at 350 GHz signal frequency

    Science.gov (United States)

    Lemzyakov, S.; Tarasov, M.; Mahashabde, S.; Yusupov, R.; Kuzmin, L.; Edelman, V.

    2018-03-01

    Response time constant of a SINIS bolometer integrated in an annular ring antenna was measured at a bath temperature of 100 mK. Samples comprising superconducting aluminium electrodes and normal-metal Al/Fe strip connected to electrodes via tunnel junctions were fabricated on oxidized Si substrate using shadow evaporation. The bolometer was illuminated by a fast black-body radiation source through a band-pass filter centered at 350 GHz with a passband of 7 GHz. Radiation source is a thin NiCr film on sapphire substrate. For rectangular 10÷100 μs current pulse the radiation front edge was rather sharp due to low thermal capacitance of NiCr film and low thermal conductivity of substrate at temperatures in the range 1-4 K. The rise time of the response was ~1-10 μs. This time presumably is limited by technical reasons: high dynamic resistance of series array of bolometers and capacitance of a long twisted pair wiring from SINIS bolometer to a room-temperature amplifier.

  6. Systolic time intervals vs invasive predictors of fluid responsiveness after coronary artery bypass surgery(dagger)

    NARCIS (Netherlands)

    Smorenberg, A.; Lust, E.J.; Beishuizen, A.; Meijer, J.H.; Verdaasdonk, R.M.; Groeneveld, A.B.J.

    2013-01-01

    OBJECTIVES: Haemodynamic parameters for predicting fluid responsiveness in intensive care patients are invasive, technically challenging or not universally applicable. We compared the initial systolic time interval (ISTI), a non-invasive measure of the time interval between the electrical and

  7. Effects of partial reinforcement and time between reinforced trials on terminal response rate in pigeon autoshaping.

    Science.gov (United States)

    Gottlieb, Daniel A

    2006-03-01

    Partial reinforcement often leads to asymptotically higher rates of responding and number of trials with a response than does continuous reinforcement in pigeon autoshaping. However, comparisons typically involve a partial reinforcement schedule that differs from the continuous reinforcement schedule in both time between reinforced trials and probability of reinforcement. Two experiments examined the relative contributions of these two manipulations to asymptotic response rate. Results suggest that the greater responding previously seen with partial reinforcement is primarily due to differential probability of reinforcement and not differential time between reinforced trials. Further, once established, differences in responding are resistant to a change in stimulus and contingency. Secondary response theories of autoshaped responding (theories that posit additional response-augmenting or response-attenuating mechanisms specific to partial or continuous reinforcement) cannot fully accommodate the current body of data. It is suggested that researchers who study pigeon autoshaping train animals on a common task prior to training them under different conditions.

  8. Multi-month prescriptions, fast-track refills, and community ART groups: results from a process evaluation in Malawi on using differentiated models of care to achieve national HIV treatment goals.

    Science.gov (United States)

    Prust, Margaret L; Banda, Clement K; Nyirenda, Rose; Chimbwandira, Frank; Kalua, Thokozani; Jahn, Andreas; Eliya, Michael; Callahan, Katie; Ehrenkranz, Peter; Prescott, Marta R; McCarthy, Elizabeth A; Tagar, Elya; Gunda, Andrews

    2017-07-21

    In order to facilitate scale-up of antiretroviral therapy (ART) in Malawi, innovative and pragmatic models have been developed to optimize the efficiency of HIV service delivery. In particular, three models of differentiated care have emerged for stable patients: adjusted appointment spacing through multi-month scripting (MMS); fast-track drug refills (FTRs) on alternating visits; and community ART groups (CAGs) where group members rotate in collecting medications at the facility for all members. This study aimed to assess the extent to which ART patients in Malawi are differentiated based on clinical stability and describe the characteristics and costs associated with the models of differentiated care offered. A mixed methods process evaluation was conducted from 30 purposefully selected ART facilities. Cross-sectional data for this evaluation was collected between February and May 2016. The following forms of data collection are reported here: structured surveys with 136 health care workers; reviews of 75,364 patient clinical records; 714 observations of visit time and flow; and 30 questionnaires on facility characteristics. Among ART patients, 77.5% (95% confidence interval [CI] 74.1-80.6) were eligible for differentiated models of care based on criteria for clinical stability from national guidelines. Across all facilities, 69% of patients were receiving MMS. In facilities offering FTRs and CAGs, 67% and 6% of patients were enrolled in the models, respectively. However, eligibility criteria were used inconsistently: 72.9% (95% CI 66.3-78.6) of eligible patients and 42.3% (95% CI 33.1-52.0) ineligible patients received MMS. Results indicated that patient travel and time costs were reduced by 67%, and the unit costs of ART service delivery through the MMS, FTR and CAG models were similar, representing a reduction of approximately 10% in the annual unit cost of providing care to stable patients that receive no model. MMS is being implemented nationally and has

  9. Distributed synchronization of networked drive-response systems: A nonlinear fixed-time protocol.

    Science.gov (United States)

    Zhao, Wen; Liu, Gang; Ma, Xi; He, Bing; Dong, Yunfeng

    2017-11-01

    The distributed synchronization of networked drive-response systems is investigated in this paper. A novel nonlinear protocol is proposed to ensure that the tracking errors converge to zeros in a fixed-time. By comparison with previous synchronization methods, the present method considers more practical conditions and the synchronization time is not dependent of arbitrary initial conditions but can be offline pre-assign according to the task assignment. Finally, the feasibility and validity of the presented protocol have been illustrated by a numerical simulation. Copyright © 2017. Published by Elsevier Ltd.

  10. Capillary refill time: a study of interobserver reliability among nurses and nurse assistants

    DEFF Research Database (Denmark)

    Brabrand, Mikkel; Hosbond, Susanne; Folkestad, Lars

    2011-01-01

    assistants would grade CRT. METHODS: We recorded a video of the index finger of six medical patients and these were shown to nurses and nurse assistants. They were asked to record the CRT and whether they found this value to be normal. The data were analyzed using the Fleiss Kappa Coefficient Analysis...... 130 mmHg. All had arterial blood oxygen saturation above 92% and all but one had normal body temperature. The kappa value for normality was 0.56. The interclass correlation of measurement of CRT was 0.62. CONCLUSION: This is the largest interobserver study of CRT when looking at the number...... of observers. We found an only moderate agreement for the exact value of CRT and a moderate agreement for normality. We believe that CRT should be used with caution in clinical practice....

  11. Ultrasonic RF time series for early assessment of the tumor response to chemotherapy.

    Science.gov (United States)

    Lin, Qingguang; Wang, Jianwei; Li, Qing; Lin, Chunyi; Guo, Zhixing; Zheng, Wei; Yan, Cuiju; Li, Anhua; Zhou, Jianhua

    2018-01-05

    Ultrasound radio-frequency (RF) time series have been shown to carry tissue typing information. To evaluate the potential of RF time series for early prediction of tumor response to chemotherapy, 50MCF-7 breast cancer-bearing nude mice were randomized to receive cisplatin and paclitaxel (treatment group; n = 26) or sterile saline (control group; n = 24). Sequential ultrasound imaging was performed on days 0, 3, 6, and 8 of treatment to simultaneously collect B-mode images and RF data. Six RF time series features, slope, intercept, S1, S2, S3 , and S4 , were extracted during RF data analysis and contrasted with microstructural tumor changes on histopathology. Chemotherapy administration reduced tumor growth relative to control on days 6 and 8. Compared with day 0, intercept, S1 , and S2 were increased while slope was decreased on days 3, 6, and 8 in the treatment group. Compared with the control group, intercept, S1, S2, S3 , and S4 were increased, and slope was decreased, on days 3, 6, and 8 in the treatment group. Tumor cell density decreased significantly in the latter on day 3. We conclude that ultrasonic RF time series analysis provides a simple way to noninvasively assess the early tumor response to chemotherapy.

  12. Control-focused, nonlinear and time-varying modelling of dielectric elastomer actuators with frequency response analysis

    International Nuclear Information System (INIS)

    Jacobs, William R; Dodd, Tony J; Anderson, Sean R; Wilson, Emma D; Porrill, John; Assaf, Tareq; Rossiter, Jonathan

    2015-01-01

    Current models of dielectric elastomer actuators (DEAs) are mostly constrained to first principal descriptions that are not well suited to the application of control design due to their computational complexity. In this work we describe an integrated framework for the identification of control focused, data driven and time-varying DEA models that allow advanced analysis of nonlinear system dynamics in the frequency-domain. Experimentally generated input–output data (voltage-displacement) was used to identify control-focused, nonlinear and time-varying dynamic models of a set of film-type DEAs. The model description used was the nonlinear autoregressive with exogenous input structure. Frequency response analysis of the DEA dynamics was performed using generalized frequency response functions, providing insight and a comparison into the time-varying dynamics across a set of DEA actuators. The results demonstrated that models identified within the presented framework provide a compact and accurate description of the system dynamics. The frequency response analysis revealed variation in the time-varying dynamic behaviour of DEAs fabricated to the same specifications. These results suggest that the modelling and analysis framework presented here is a potentially useful tool for future work in guiding DEA actuator design and fabrication for application domains such as soft robotics. (paper)

  13. Detecting lies about consumer attitudes using the timed antagonistic response alethiometer.

    Science.gov (United States)

    Gregg, Aiden P; Mahadevan, Nikhila; Edwards, Sonja E; Klymowsky, James

    2014-09-01

    The Timed Antagonistic Response Alethiometer (TARA) is a true-false statement classification task that diagnoses lying on the basis of slower average response speeds. Previous research (Gregg in Applied Cognitive Psychology, 21, 621-647, 2007) showed that a computer-based TARA was about 80 % accurate when its statements conveyed demographic facts or religious views. Here, we tested the TARA's diagnostic potential when its statements conveyed attitudes-here, toward both branded and generic consumer products-across different versions of the TARA (Exps. 1a, 1b, and 1c), as well as across consecutive administrations (Exp. 2). The results generalized well across versions, and maximal accuracy rates exceeding 80 % were obtained, although accuracy declined somewhat upon readministration. Overall, the TARA shows promise as a comparatively cheap, convenient, and diagnostic index of lying about attitudes.

  14. The dorsal medial frontal cortex is sensitive to time on task, not response conflict or error likelihood.

    Science.gov (United States)

    Grinband, Jack; Savitskaya, Judith; Wager, Tor D; Teichert, Tobias; Ferrera, Vincent P; Hirsch, Joy

    2011-07-15

    The dorsal medial frontal cortex (dMFC) is highly active during choice behavior. Though many models have been proposed to explain dMFC function, the conflict monitoring model is the most influential. It posits that dMFC is primarily involved in detecting interference between competing responses thus signaling the need for control. It accurately predicts increased neural activity and response time (RT) for incompatible (high-interference) vs. compatible (low-interference) decisions. However, it has been shown that neural activity can increase with time on task, even when no decisions are made. Thus, the greater dMFC activity on incompatible trials may stem from longer RTs rather than response conflict. This study shows that (1) the conflict monitoring model fails to predict the relationship between error likelihood and RT, and (2) the dMFC activity is not sensitive to congruency, error likelihood, or response conflict, but is monotonically related to time on task. Copyright © 2010 Elsevier Inc. All rights reserved.

  15. Finite-time hybrid projective synchronization of the drive-response complex networks with distributed-delay via adaptive intermittent control

    Science.gov (United States)

    Cheng, Lin; Yang, Yongqing; Li, Li; Sui, Xin

    2018-06-01

    This paper studies the finite-time hybrid projective synchronization of the drive-response complex networks. In the model, general transmission delays and distributed delays are also considered. By designing the adaptive intermittent controllers, the response network can achieve hybrid projective synchronization with the drive system in finite time. Based on finite-time stability theory and several differential inequalities, some simple finite-time hybrid projective synchronization criteria are derived. Two numerical examples are given to illustrate the effectiveness of the proposed method.

  16. Sensor response time calculation with no stationary signals from a Nuclear Power Plant

    International Nuclear Information System (INIS)

    Vela, O.; Vallejo, I.

    1998-01-01

    Protection systems in a Nuclear Power Plant have to response in a specific time fixed by design requirements. This time includes the event detection (sensor delay) and the actuation time system. This time is obtained in refuel simulating the physics event, which trigger the protection system, with an electric signal and measuring the protection system actuation time. Nowadays sensor delay is calculated with noise analysis techniques. The signals are measured in Control Room during the normal operation of the Plant, decreasing both the cost in time and personal radioactive exposure. The noise analysis techniques require stationary signals but normally the data collected are mixed with process signals that are no stationary. This work shows the signals processing to avoid no-stationary components using conventional filters and new wavelets analysis. (Author) 2 refs

  17. Analysis of Time and Space Invariance of BOLD Responses in the Rat Visual System

    DEFF Research Database (Denmark)

    Bailey, Christopher; Sanganahalli, Basavaraju G; Herman, Peter

    2012-01-01

    Neuroimaging studies of functional magnetic resonance imaging (fMRI) and electrophysiology provide the linkage between neural activity and the blood oxygenation level-dependent (BOLD) response. Here, BOLD responses to light flashes were imaged at 11.7T and compared with neural recordings from...... for general linear modeling (GLM) of BOLD responses. Light flashes induced high magnitude neural/BOLD responses reproducibly from both regions. However, neural/BOLD responses from SC and V1 were markedly different. SC signals followed the boxcar shape of the stimulation paradigm at all flash rates, whereas V1...... signals were characterized by onset/offset transients that exhibited different flash rate dependencies. We find that IRF(SC) is generally time-invariant across wider flash rate range compared with IRF(V1), whereas IRF(SC) and IRF(V1) are both space invariant. These results illustrate the importance...

  18. A storm-time plasmasphere evolution study using data assimilation

    Science.gov (United States)

    Nikoukar, R.; Bust, G. S.; Bishop, R. L.; Coster, A. J.; Lemon, C.; Turner, D. L.; Roeder, J. L.

    2017-12-01

    In this work, we study the evolution of the Earth's plasmasphere during geomagnetic active periods using the Plasmasphere Data Assimilation (PDA) model. The total electron content (TEC) measurements from an extensive network of global ground-based GPS receivers as well as GPS receivers on-board Constellation Observing System for Meteorology, Ionosphere and Climate (COSMIC) satellites and Communications/Navigation Outage Forecasting System (C/NOFS) satellite are ingested into the model. Global Core Plasma model, which is an empirical plasmasphere model, is utilized as the background model. Based on the 3D-VAR optimization, the PDA assimilative model benefits from incorporation of regularization techniques to prevent non-physical altitudinal variation in density estimates due to the limited-angle observational geometry. This work focuses on the plasmapause location, plasmasphere erosion time scales and refilling rates during the main and recovery phases of geomagnetic storms as estimated from the PDA 3-dimensional global maps of electron density in the ionosphere/plasmasphere. The comparison between the PDA results with in-situ density measurements from THEMIS and Van Allen Probes, and the RCM-E first-principle model will be also presented.

  19. Big Data Analytics for Demand Response: Clustering Over Space and Time

    Energy Technology Data Exchange (ETDEWEB)

    Chelmis, Charalampos [Univ. of Southern California, Los Angeles, CA (United States); Kolte, Jahanvi [Nirma Univ., Gujarat (India); Prasanna, Viktor K. [Univ. of Southern California, Los Angeles, CA (United States)

    2015-10-29

    The pervasive deployment of advanced sensing infrastructure in Cyber-Physical systems, such as the Smart Grid, has resulted in an unprecedented data explosion. Such data exhibit both large volumes and high velocity characteristics, two of the three pillars of Big Data, and have a time-series notion as datasets in this context typically consist of successive measurements made over a time interval. Time-series data can be valuable for data mining and analytics tasks such as identifying the “right” customers among a diverse population, to target for Demand Response programs. However, time series are challenging to mine due to their high dimensionality. In this paper, we motivate this problem using a real application from the smart grid domain. We explore novel representations of time-series data for BigData analytics, and propose a clustering technique for determining natural segmentation of customers and identification of temporal consumption patterns. Our method is generizable to large-scale, real-world scenarios, without making any assumptions about the data. We evaluate our technique using real datasets from smart meters, totaling ~ 18,200,000 data points, and show the efficacy of our technique in efficiency detecting the number of optimal number of clusters.

  20. Factors for incomplete adherence to antiretroviral therapy including drug refill and clinic visits among older adults living with human immunodeficiency virus - cross-sectional study in South Africa.

    Science.gov (United States)

    Barry, Abbie; Ford, Nathan; El-Khatib, Ziad

    2018-03-01

    To assess adherence outcomes to antiretroviral therapy (ART) of recipients ≥50 years in Soweto, South Africa. This was a secondary data analysis for a cross-sectional study at two HIV clinics in Soweto. Data on ART adherence and covariates were gathered through structured interviews with HIV 878 persons living with HIV (PLHIV) receiving ART. Logistic regression analysis was used to assess associations. PLHIV ≥50 years (n = 103) were more likely to miss clinic visits during the last six months than PLHIV aged 25-49 (OR 2.15; 95%CI 1.10-4.18). PLHIV ≥50 years with no or primary-level education were less likely to have missed a clinic visit during the last six months than PLHIV with secondary- or tertiary-level education in the same age category (OR 0.3; 95%CI 0.1-1.1), as were PLHIV who did not disclose their status (OR 0.2; 95%CI 0-1.1). There was no evidence of increased risk for non-adherence to ART pills and drug refill visits among older PLHIV. Missing a clinic visit was more common among older PLHIV who were more financially vulnerable. Further studies are needed to verify these findings and identify new risk factors associated with ART adherence. © 2017 John Wiley & Sons Ltd.

  1. Statistical analysis of hydrological response in urbanising catchments based on adaptive sampling using inter-amount times

    Science.gov (United States)

    ten Veldhuis, Marie-Claire; Schleiss, Marc

    2017-04-01

    Urban catchments are typically characterised by a more flashy nature of the hydrological response compared to natural catchments. Predicting flow changes associated with urbanisation is not straightforward, as they are influenced by interactions between impervious cover, basin size, drainage connectivity and stormwater management infrastructure. In this study, we present an alternative approach to statistical analysis of hydrological response variability and basin flashiness, based on the distribution of inter-amount times. We analyse inter-amount time distributions of high-resolution streamflow time series for 17 (semi-)urbanised basins in North Carolina, USA, ranging from 13 to 238 km2 in size. We show that in the inter-amount-time framework, sampling frequency is tuned to the local variability of the flow pattern, resulting in a different representation and weighting of high and low flow periods in the statistical distribution. This leads to important differences in the way the distribution quantiles, mean, coefficient of variation and skewness vary across scales and results in lower mean intermittency and improved scaling. Moreover, we show that inter-amount-time distributions can be used to detect regulation effects on flow patterns, identify critical sampling scales and characterise flashiness of hydrological response. The possibility to use both the classical approach and the inter-amount-time framework to identify minimum observable scales and analyse flow data opens up interesting areas for future research.

  2. Response Time Measurements of the NIF DANTE XRD-31 X-Ray Diodes (Pre-print)

    International Nuclear Information System (INIS)

    Pellinen, Don; Griffin, Michael

    2009-01-01

    The XRD-31 is a fast, windowless X-ray vacuum photodiode developed by EG and G. It is currently the primary fast X-ray detector used to diagnose the X-rays on NIF and OMEGA on the multichannel DANTE spectrometer. The XRD-31 has a dynamic range of less than 1e-12 amps to more than 10 amps. A technique is described to measure the impulse response of the diodes to a 150 fs pulse of 200 nm laser light and a method to calculate the 'risetime' for a square pulse and compare it with the computed electron transit time from the photocathode to the anode. Measured response time for 5 XRD-31s assembled in early 2004 was 149.7 ps +-2.75 ps

  3. Review of Real-time Electricity Markets for Integrating Distributed Energy Resources and Demand Response

    DEFF Research Database (Denmark)

    Wang, Qi; Zhang, Chunyu; Ding, Yi

    2015-01-01

    The high penetration of both Distributed Energy Resources (DER) and Demand Response (DR) in modern power systems requires a sequence of advanced strategies and technologies for maintaining system reliability and flexibility. Real-time electricity markets (RTM) are the nondiscriminatory transaction...... platforms for providing necessary balancing services, where the market clearing (nodal or zonal prices depending on markets) is very close to real time operations of power systems. One of the primary functions of RTMs in modern power systems is establishing an efficient and effective mechanism for small DER...... and DR to participate in balancing market transactions, while handling their meteorological or intermittent characteristics, facilitating asset utilization, and stimulating their active responses. Consequently, RTMs are dedicated to maintaining the flexibility and reliability of power systems. This paper...

  4. Evaluation of time integration methods for transient response analysis of nonlinear structures

    International Nuclear Information System (INIS)

    Park, K.C.

    1975-01-01

    Recent developments in the evaluation of direct time integration methods for the transient response analysis of nonlinear structures are presented. These developments, which are based on local stability considerations of an integrator, show that the interaction between temporal step size and nonlinearities of structural systems has a pronounced effect on both accuracy and stability of a given time integration method. The resulting evaluation technique is applied to a model nonlinear problem, in order to: 1) demonstrate that it eliminates the present costly process of evaluating time integrator for nonlinear structural systems via extensive numerical experiments; 2) identify the desirable characteristics of time integration methods for nonlinear structural problems; 3) develop improved stiffly-stable methods for application to nonlinear structures. Extension of the methodology for examination of the interaction between a time integrator and the approximate treatment of nonlinearities (such as due to pseudo-force or incremental solution procedures) is also discussed. (Auth.)

  5. Influence of time pressure in a simple response task, a choice-by-location task, and the Simon task

    NARCIS (Netherlands)

    van der Lubbe, Robert Henricus Johannes; Jaśkowski, Piotr; Wauschkuhn, Bernd; Verleger, Rolf

    2001-01-01

    Examined the influence of strategy for a simple response task, a choice-by-location task, and the Simon task by varying time pressure in 11 Ss (mean age 28 yrs). Besides reaction time (RT) and accuracy, we measured response force and derived two measures from the event-related EEG potential to form

  6. The effect of stimulus intensity on response time and accuracy in dynamic, temporally constrained environments.

    Science.gov (United States)

    Causer, J; McRobert, A P; Williams, A M

    2013-10-01

    The ability to make accurate judgments and execute effective skilled movements under severe temporal constraints are fundamental to elite performance in a number of domains including sport, military combat, law enforcement, and medicine. In two experiments, we examine the effect of stimulus strength on response time and accuracy in a temporally constrained, real-world, decision-making task. Specifically, we examine the effect of low stimulus intensity (black) and high stimulus intensity (sequin) uniform designs, worn by teammates, to determine the effect of stimulus strength on the ability of soccer players to make rapid and accurate responses. In both field- and laboratory-based scenarios, professional soccer players viewed developing patterns of play and were required to make a penetrative pass to an attacking player. Significant differences in response accuracy between uniform designs were reported in laboratory- and field-based experiments. Response accuracy was significantly higher in the sequin compared with the black uniform condition. Response times only differed between uniform designs in the laboratory-based experiment. These findings extend the literature into a real-world environment and have significant implications for the design of clothing wear in a number of domains. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. A Preliminary Study of Individual Responses to Real-Time Pitch and Formant Perturbations

    DEFF Research Database (Denmark)

    MacDonald, Ewen; Munhall, Kevin G.

    2012-01-01

    Previous studies have demonstrated a wide range in individuals’ compensations in response to real-time alterations of the auditory feedback of both pitch and formant frequencies. One potential source of this variability may be individual differences in the relative weighting of auditory and somat...

  8. Non-linear wave loads and ship responses by a time-domain strip theory

    DEFF Research Database (Denmark)

    Xia, Jinzhu; Wang, Zhaohui; Jensen, Jørgen Juncher

    1998-01-01

    . Based on this time-domain strip theory, an efficient non-linear hydroelastic method of wave- and slamming-induced vertical motions and structural responses of ships is developed, where the structure is represented as a Timoshenko beam. Numerical calculations are presented for the S175 Containership...

  9. Non-Linear Wave Loads and Ship responses by a time-domain Strip Theory

    DEFF Research Database (Denmark)

    Xia, Jinzhu; Wang, Zhaohui; Jensen, Jørgen Juncher

    1998-01-01

    . Based on this time-domain strip theory, an efficient non-linear hyroelastic method of wave- and slamming-induced vertical motions and structural responses of ships is developed, where the structure is represented by the Timoshenko beam theory. Numerical calculations are presented for the S175...

  10. How does the predicted geomagnetic main field variation alter the thermosphere-ionosphere storm-time response?

    Science.gov (United States)

    Maute, A. I.; Lu, G.; Richmond, A. D.

    2017-12-01

    Earth's magnetic main field plays an important role in the thermosphere-ionosphere (TI) system, as well as its coupling to Earth's magnetosphere. The ionosphere consists of a weakly ionized plasma strongly influenced by the main field and embedded in the thermosphere. Therefore, ion-neutral coupling and ionospheric electrodynamics can influence the plasma distribution and neutral dynamics. There are strong longitude variations of the TI storm response. At high latitude magnetosphere-ionosphere coupling is organized by the geomagnetic main field, leading in general to stronger northern middle latitude storm time response in the American sector due to the geomagnetic dipole location. In addition, the weak geomagnetic main field in the American sector leads to larger local ExB drift and can alter the plasma densities. During geomagnetic storms the intense energy input into the high latitude region is redistributed globally, leading to thermospheric heating, wind circulation changes and alterations of the ionospheric electrodynamics. The storm time changes are measurable in the plasma density, ion drift, temperature, neutral composition, and other parameters. All these changes depend, to some degree, on the geomagnetic main field which changes on decadal time scales. In this study, we employ a forecast model of the geomagnetic main field based on data assimilation and geodynamo modeling [Aubert et al., 2015]. The main field model predicts that in 50 years the South Atlantic Anomaly is further weakened by 2 mT and drifts westward by approximately 10o. The dipole axis moves northward and westward by 2o and 6o, respectively. Simulating the March 2015 geomagnetic storm with the Thermosphere-Ionosphere Electrodynamics General Circulation Model (TIE-GCM) driven by the Assimilative Mapping of Ionospheric Electrodynamics (AMIE), we evaluate the thermosphere-ionosphere response using the geomagnetic main field of 2015, 2065, and 2115. We compare the TI response for 2015 with

  11. Time Course of the Soleus M Response and H Reflex after Lidocaine Tibial Nerve Block in the Rat

    Directory of Open Access Journals (Sweden)

    Kévin Buffenoir

    2013-01-01

    Full Text Available Aims. In spastic subjects, lidocaine is often used to induce a block predictive of the result provided by subsequent surgery. Lidocaine has been demonstrated to inhibit the Hoffmann (H reflex to a greater extent than the direct motor (M response induced by electrical stimulation, but the timecourse of these responses has not been investigated. Methods. An animal (rat model of the effects of lidocaine on M and H responses was therefore developed to assess this time course. M and H responses were recorded in 18 adult rats before and after application of lidocaine to the sciatic nerve. Results. Two to five minutes after lidocaine injection, M responses were markedly reduced (mean reduction of 44% and H reflexes were completely abolished. Changes were observed more rapidly for the H reflex. The effects of lidocaine then persisted for 100 minutes. The effect of lidocaine was therefore more prolonged on the H reflex than on the M response. Conclusion. This study confirms that lidocaine blocks not only alpha motoneurons but also Ia afferent fibres responsible for the H reflex. The authors describe, for the first time, the detailed time course of the effect of lidocaine on direct or reflex activation of motoneurons in the rat.

  12. Genotyping three SNPs affecting warfarin drug response by isothermal real-time HDA assays.

    Science.gov (United States)

    Li, Ying; Jortani, Saeed A; Ramey-Hartung, Bronwyn; Hudson, Elizabeth; Lemieux, Bertrand; Kong, Huimin

    2011-01-14

    The response to the anticoagulant drug warfarin is greatly affected by genetic polymorphisms in the VKORC1 and CYP2C9 genes. Genotyping these polymorphisms has been shown to be important in reducing the time of the trial and error process for finding the maintenance dose of warfarin thus reducing the risk of adverse effects of the drug. We developed a real-time isothermal DNA amplification system for genotyping three single nucleotide polymorphisms (SNPs) that influence warfarin response. For each SNP, real-time isothermal Helicase Dependent Amplification (HDA) reactions were performed to amplify a DNA fragment containing the SNP. Amplicons were detected by fluorescently labeled allele specific probes during real-time HDA amplification. Fifty clinical samples were analyzed by the HDA-based method, generating a total of 150 results. Of these, 148 were consistent between the HDA-based assays and a reference method. The two samples with unresolved HDA-based test results were repeated and found to be consistent with the reference method. The HDA-based assays demonstrated a clinically acceptable performance for genotyping the VKORC1 -1639G>A SNP and two SNPs (430C>T and 1075A>C) for the CYP2C9 enzyme (CYP2C9*2 and CYP2C9*3), all of which are relevant in warfarin pharmacogenentics. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Time-effect relationship of immunological adaptive response induced by low dose X-irradiation in mice

    International Nuclear Information System (INIS)

    Zhao Yong; Gong Shouliang; Liu Shuzheng

    1995-01-01

    Kunming mice irradiated with whole-body X-rays were used to observe time-effect relationship of immunological adaptive response induced by ionizing radiation. The results showed that pre-irradiation dose of 75 mGy X-rays with the intervals of 6-48 h between pre-irradiation and challenge irradiation could induce immunological adaptive response in the spontaneous proliferation of thymocytes and the responses of splenocytes to Con A and LPS in mice at 18-24 h after challenge irradiation with 1.5-2.0 Gy X-rays

  14. Repeated diffusion MRI reveals earliest time point for stratification of radiotherapy response in brain metastases

    DEFF Research Database (Denmark)

    Mahmood, Faisal; Johannesen, Helle H; Geertsen, Poul

    2017-01-01

    An imaging biomarker for early prediction of treatment response potentially provides a non-invasive tool for better prognostics and individualized management of the disease. Radiotherapy (RT) response is generally related to changes in gross tumor volume manifesting months later. In this prospect......An imaging biomarker for early prediction of treatment response potentially provides a non-invasive tool for better prognostics and individualized management of the disease. Radiotherapy (RT) response is generally related to changes in gross tumor volume manifesting months later....... In this prospective study we investigated the apparent diffusion coefficient (ADC), perfusion fraction and pseudo diffusion coefficient derived from diffusion weighted MRI as potential early biomarkers for radiotherapy response of brain metastases. It was a particular aim to assess the optimal time point...

  15. Transient response of a five-region nonequilibrium real-time pressurizer model

    International Nuclear Information System (INIS)

    Fakory, M.R.; Seifaee, F.

    1987-01-01

    Recent accidents at nuclear power plants in the US and abroad have prompted accurate analysis and simulation of the plant systems and the training of reactor operators on plant-specific simulators that are equipped with the simulation models. Consequently, several models for real-time and off-time simulation of nuclear reactor systems, with various levels of accuracy and simulation fidelity, have been introduced. Experience with power plant simulation demonstrates that in order to realistically predict and simulate reactor responses during unanticipated transients, it is necessary to equip the simulation model with a multielement pressurizer model. The objective of this paper is to present the results of a five-region drift-flux-based pressurizer model, which has been developed for integration with real-time training simulators. A comparison between the plant data and the results of the nonequilibrium pressurizer model demonstrates that the model is well capable of close simulation of dynamic behavior of the pressurizer system

  16. On-line testing of response time and calibration of temperature and pressure sensors in nuclear power plants

    International Nuclear Information System (INIS)

    Hashemian, H.M.

    1995-01-01

    Periodic calibrations and response time measurements are necessary for temperature and pressure sensors in the safety systems of nuclear power plants. Conventional measurement methods require the test to be performed at the sensor location or involve removing the sensor from the process and performing the tests in a laboratory or on the bench. The conventional methods are time consuming and have the potential of causing wear and tear on the equipment, can expose the test personnel to radiation and other harsh environments, and increase the length of the plant outage. Also, the conventional methods do not account for the installation effects which may have an influence on sensor performance. On-line testing methods alleviate these problems by providing remote sensor response time and calibration capabilities. For temperature sensors such as Resistance Temperature Detectors (RTDs) and thermocouples, an on-line test method called the Loop Current Step Response (LCSR) technique has been developed, and for pressure transmitters, an on-line method called noise analysis which was available for reactor diagnostics was validated for response time testing applications. Both the LCSR and noise analysis tests are performed periodically in U.S. nuclear power plants to meet the plant technical specification requirements for response time testing of safety-related sensors. Automated testing of the calibration of both temperature and pressure sensors can be accomplished through an on-line monitoring system installed in the plant. The system monitors the DC output of the sensors over the fuel cycle to determine if any calibration drift has occurred. Changes in calibration can be detected using signal averaging and intercomparison methods and analytical redundancy techniques. (author)

  17. Cemaran Mikroba Escherichia coli dan Total Bakteri Koliform pada Air Minum Isi Ulang

    Directory of Open Access Journals (Sweden)

    Rolan Sudirman Pakpahan

    2015-05-01

    there is no guarantee that refill drinking water quality meets any requirement every time. Results of refill drinking water sample in Kupang City in 2013 showed the water was 37.5% contaminated by microbes. This study aimed to analyze microbial contamination and determine determinants of Escherichia coli (E. coli and total Coliform on refill drinking water. This study used cross sectional design on January - March 2015. The population was 51 depots determined using total sampling technique. Data analysis was conducted in univariate, bivariate using simple logistic regression test and multivariate using multiple logistic regression test. Results showed drinking water contaminated by microbes worth 26 depots (51%, by E. coli 33.33% and by total Coliform 51%. Microbial contamination determinants using bivariate were knowledge (p value = 0.01 and behavior of operator (p value = 0.05. Meanwhile, microbial contamination determinants conducting multivariate were knowledge (p value = 0.026, hygiene of operator (p value = 0.05 and depot sanitation (p value = 0.044. Most dominating variables influencing microbial contamination are knowledge, operator’s hygiene and depot sanitation.

  18. 78 FR 38949 - Computer Security Incident Coordination (CSIC): Providing Timely Cyber Incident Response

    Science.gov (United States)

    2013-06-28

    ... exposed to various forms of cyber attack. In some cases, attacks can be thwarted through the use of...-3383-01] Computer Security Incident Coordination (CSIC): Providing Timely Cyber Incident Response... systems will be successfully attacked. When a successful attack occurs, the job of a Computer Security...

  19. Joint Testlet Cognitive Diagnosis Modeling for Paired Local Item Dependence in Response Times and Response Accuracy

    Directory of Open Access Journals (Sweden)

    Peida Zhan

    2018-04-01

    Full Text Available In joint models for item response times (RTs and response accuracy (RA, local item dependence is composed of local RA dependence and local RT dependence. The two components are usually caused by the same common stimulus and emerge as pairs. Thus, the violation of local item independence in the joint models is called paired local item dependence. To address the issue of paired local item dependence while applying the joint cognitive diagnosis models (CDMs, this study proposed a joint testlet cognitive diagnosis modeling approach. The proposed approach is an extension of Zhan et al. (2017 and it incorporates two types of random testlet effect parameters (one for RA and the other for RTs to account for paired local item dependence. The model parameters were estimated using the full Bayesian Markov chain Monte Carlo (MCMC method. The 2015 PISA computer-based mathematics data were analyzed to demonstrate the application of the proposed model. Further, a brief simulation study was conducted to demonstrate the acceptable parameter recovery and the consequence of ignoring paired local item dependence.

  20. Real-time Medical Emergency Response System: Exploiting IoT and Big Data for Public Health.

    Science.gov (United States)

    Rathore, M Mazhar; Ahmad, Awais; Paul, Anand; Wan, Jiafu; Zhang, Daqiang

    2016-12-01

    Healthy people are important for any nation's development. Use of the Internet of Things (IoT)-based body area networks (BANs) is increasing for continuous monitoring and medical healthcare in order to perform real-time actions in case of emergencies. However, in the case of monitoring the health of all citizens or people in a country, the millions of sensors attached to human bodies generate massive volume of heterogeneous data, called "Big Data." Processing Big Data and performing real-time actions in critical situations is a challenging task. Therefore, in order to address such issues, we propose a Real-time Medical Emergency Response System that involves IoT-based medical sensors deployed on the human body. Moreover, the proposed system consists of the data analysis building, called "Intelligent Building," depicted by the proposed layered architecture and implementation model, and it is responsible for analysis and decision-making. The data collected from millions of body-attached sensors is forwarded to Intelligent Building for processing and for performing necessary actions using various units such as collection, Hadoop Processing (HPU), and analysis and decision. The feasibility and efficiency of the proposed system are evaluated by implementing the system on Hadoop using an UBUNTU 14.04 LTS coreTMi5 machine. Various medical sensory datasets and real-time network traffic are considered for evaluating the efficiency of the system. The results show that the proposed system has the capability of efficiently processing WBAN sensory data from millions of users in order to perform real-time responses in case of emergencies.

  1. Characterizing Scintillator Response with Neutron Time-of-Flight

    Science.gov (United States)

    Palmisano, Kevin; Visca, Hannah; Caves, Louis; Wilkinson, Corey; McClow, Hannah; Padalino, Stephen; Forrest, Chad; Katz, Joe; Sangster, Craig; Regan, Sean

    2017-10-01

    Neutron scintillator diagnostics for ICF can be characterized using the neutron time-of-flight (nTOF) line on Geneseo's 1.7 MV Tandem Pelletron Accelerator. Neutron signals can be differentiated from gamma signals by employing a coincidence method called the associated particle technique (APT). In this measurement, a 2.1 MeV beam of deuterons incident on a deuterated polyethylene target produces neutrons via the d(d,n)3He reaction. A BC-412 plastic scintillator, placed at a scattering angle of 152º, detects 1.76 MeV neutrons in coincidence with the 2.56 MeV 3He ions at an associated angle of 10º. The APT is used to identify the 1.76 MeV neutron while the nTOF line determines its energy. By gating only mono-energetic neutrons, the instrument response function of the scintillator can be determined free from background scattered neutrons and gamma rays. Funded in part by a Grant from the DOE, through the Laboratory for Laser Energetics.

  2. Correlations of Eisenia fetida metabolic responses to extractable phenanthrene concentrations through time

    Energy Technology Data Exchange (ETDEWEB)

    McKelvie, Jennifer R.; Wolfe, David M.; Celejewski, Magda; Simpson, Andre J. [Department of Physical and Environmental Sciences, University of Toronto, 1265 Military Trail, Toronto, Ontario, M1C 1A4 (Canada); Simpson, Myrna J., E-mail: myrna.simpson@utoronto.c [Department of Physical and Environmental Sciences, University of Toronto, 1265 Military Trail, Toronto, Ontario, M1C 1A4 (Canada)

    2010-06-15

    Eisenia fetida earthworms were exposed to phenanthrene for thirty days to compare hydroxypropyl-beta-cyclodextrin (HPCD) extraction of soil and {sup 1}H NMR earthworm metabolomics as indicators of bioavailability. The phenanthrene 28-d LC{sub 50} value was 750 mg/kg (632-891, 95% confidence intervals) for the peat soil tested. The initial phenanthrene concentration was 319 mg/kg, which biodegraded to 16 mg/kg within 15 days, at which time HPCD extraction suggested that phenanthrene was no longer bioavailable. Multivariate statistical analysis of {sup 1}H NMR spectra for E. fetida tissue extracts indicated that phenanthrene exposed and control earthworms differed throughout the 30 day experiment despite the low phenanthrene concentrations present after 15 days. This metabolic response was better correlated to total phenanthrene concentrations (Q{sup 2} = 0.59) than HPCD-extractable phenanthrene concentrations (Q{sup 2} = 0.46) suggesting that {sup 1}H NMR metabolomics offers considerable promise as a novel, molecular-level method to directly monitor the bioavailability of contaminants to earthworms in the environment. - Metabolic responses of Eisenia fetida earthworms to phenanthrene exposure are better correlated to total phenanthrene concentrations than to cyclodextrin-extractable concentrations through time.

  3. Correlations of Eisenia fetida metabolic responses to extractable phenanthrene concentrations through time

    International Nuclear Information System (INIS)

    McKelvie, Jennifer R.; Wolfe, David M.; Celejewski, Magda; Simpson, Andre J.; Simpson, Myrna J.

    2010-01-01

    Eisenia fetida earthworms were exposed to phenanthrene for thirty days to compare hydroxypropyl-β-cyclodextrin (HPCD) extraction of soil and 1 H NMR earthworm metabolomics as indicators of bioavailability. The phenanthrene 28-d LC 50 value was 750 mg/kg (632-891, 95% confidence intervals) for the peat soil tested. The initial phenanthrene concentration was 319 mg/kg, which biodegraded to 16 mg/kg within 15 days, at which time HPCD extraction suggested that phenanthrene was no longer bioavailable. Multivariate statistical analysis of 1 H NMR spectra for E. fetida tissue extracts indicated that phenanthrene exposed and control earthworms differed throughout the 30 day experiment despite the low phenanthrene concentrations present after 15 days. This metabolic response was better correlated to total phenanthrene concentrations (Q 2 = 0.59) than HPCD-extractable phenanthrene concentrations (Q 2 = 0.46) suggesting that 1 H NMR metabolomics offers considerable promise as a novel, molecular-level method to directly monitor the bioavailability of contaminants to earthworms in the environment. - Metabolic responses of Eisenia fetida earthworms to phenanthrene exposure are better correlated to total phenanthrene concentrations than to cyclodextrin-extractable concentrations through time.

  4. Resolución del Response Time Variability Problem mediante tabu search

    OpenAIRE

    Corominas Subias, Albert; García Villoria, Alberto; Pastor Moreno, Rafael

    2009-01-01

    El Response Time Variability Problem (RTVP) es un problema combinatorio de scheduling publicado recientemente en la literatura. Dicho problema de optimización combinatoria es muy fácil de formular pero muy difícil de resolver de forma exacta (es NP-hard). El RTVP se presenta cuando productos, clientes o tareas se han de secuenciar minimizando la variabilidad entre los instantes de tiempo en los que reciben los recursos que ellos necesitan. Este problema tiene una gran cantidad de aplicaciones...

  5. Age-related slowing of response selection and production in a visual choice reaction time task

    Directory of Open Access Journals (Sweden)

    David L Woods

    2015-04-01

    Full Text Available Aging is associated with delayed processing in choice reaction time (CRT tasks, but the processing stages most impacted by aging have not been clearly identified. Here, we analyzed CRT latencies in a computerized serial visual feature-conjunction task. Participants responded to a target letter (probability 40% by pressing one mouse button, and responded to distractor letters differing either in color, shape, or both features from the target (probabilities 20% each, by pressing the other mouse button. Stimuli were presented randomly to the left and right visual fields and stimulus onset asynchronies (SOAs were adaptively reduced following correct responses using a staircase procedure. In Experiment 1, we tested 1466 participants who ranged in age from 18 to 65 years. CRT latencies increased significantly with age (r = 0.47, 2.80 ms/year. Central processing time (CPT, isolated by subtracting simple reaction times (obtained in a companion experiment performed on the same day from CRT latencies, accounted for more than 80% of age-related CRT slowing, with most of the remaining increase in latency due to slowed motor responses. Participants were faster and more accurate when the stimulus location was spatially compatible with the mouse button used for responding, and this effect increased slightly with age. Participants took longer to respond to distractors with target color or shape than to distractors with no target features. However, the additional time needed to discriminate the more target-like distractors did not increase with age. In Experiment 2, we replicated the findings of Experiment 1 in a second population of 178 participants (ages 18-82 years. CRT latencies did not differ significantly in the two experiments, and similar effects of age, distractor similarity, and stimulus-response spatial compatibility were found. The results suggest that the age-related slowing in visual CRT latencies is largely due to delays in response selection and

  6. Linear response approach to active Brownian particles in time-varying activity fields

    Science.gov (United States)

    Merlitz, Holger; Vuijk, Hidde D.; Brader, Joseph; Sharma, Abhinav; Sommer, Jens-Uwe

    2018-05-01

    In a theoretical and simulation study, active Brownian particles (ABPs) in three-dimensional bulk systems are exposed to time-varying sinusoidal activity waves that are running through the system. A linear response (Green-Kubo) formalism is applied to derive fully analytical expressions for the torque-free polarization profiles of non-interacting particles. The activity waves induce fluxes that strongly depend on the particle size and may be employed to de-mix mixtures of ABPs or to drive the particles into selected areas of the system. Three-dimensional Langevin dynamics simulations are carried out to verify the accuracy of the linear response formalism, which is shown to work best when the particles are small (i.e., highly Brownian) or operating at low activity levels.

  7. Using response-time constraints in item selection to control for differential speededness in computerized adaptive testing

    NARCIS (Netherlands)

    van der Linden, Willem J.; Scrams, David J.; Schnipke, Deborah L.

    2003-01-01

    This paper proposes an item selection algorithm that can be used to neutralize the effect of time limits in computer adaptive testing. The method is based on a statistical model for the response-time distributions of the test takers on the items in the pool that is updated each time a new item has

  8. Time of day influences the voluntary intake and behavioral response to methamphetamine and food reward.

    Science.gov (United States)

    Keith, Diana R; Hart, Carl L; Robotham, Margaret; Tariq, Maliha; Le Sauter, Joseph; Silver, Rae

    2013-09-01

    The circadian timing system influences a vast array of behavioral responses. Substantial evidence indicates a role for the circadian system in regulating reward processing. Here we explore time of day effects on drug anticipation, locomotor activity, and voluntary methamphetamine (MA) and food intake in animals with ad libitum food access. We compared responses to drug versus a palatable treat during their normal sleep times in early day (zeitgeber time (ZT) 0400) or late day (ZT 1000). In the first study, using a between-subjects design, mice were given daily 1-h access to either peanut butter (PB-Alone) or to a low or high concentration of MA mixed in PB (MA+PB). In study 2, we repeated the experiment using a within-subjects design in which mice could choose between PB-Alone and MA+PB at either ZT 0400 or 1000. In study 3, the effects of MA-alone were investigated by evaluating anticipatory activity preceding exposure to nebulized MA at ZT 0400 vs. ZT 1000. Time of day effects were observed for both drug and palatable treat, such that in the between groups design, animals showed greater intake, anticipatory activity, and post-ingestional activity in the early day. Furthermore, there were differences among mice in the amount of MA ingested but individuals were self-consistent in their daily intake. The results for the within-subjects experiment also revealed robust individual differences in preference for MA+PB or PB-Alone. Interestingly, time of day effects on intake were observed only for the preferred substance. Anticipatory activity preceding administration of MA by nebulization was also greater at ZT 0400 than ZT 1000. Finally, pharmacokinetic response to MA administered intraperitoneally did not vary as a function of time of administration. The results indicate that time of day is an important variable mediating the voluntary intake and behavioral effects of reinforcers. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Time and situatedness Merleau-Ponty,s Response to McTaggart,s Paradox

    Directory of Open Access Journals (Sweden)

    Claudio Javier Cormick

    2014-12-01

    Full Text Available The article seeks to establish a relationship that has not yet been explored satisfactorily between Merleau-Ponty᾿s phenomenology of time and a central issue of analytical “theory of time”: McTaggart᾿s paradox. By clarifying the authentic meaning of Merleau-Ponty᾿s “subjectivism” regarding time, against Priest᾿s interpretation (1998, the article points out a convergence between the phenomenological approach and Michael Dummett᾿s theses developed in response to the abovementioned paradox. A “situational” solution to the paradox is attempted on the basis of Dummett᾿s ideas and Bimbenet᾿s interpretation of Merleau-Ponty᾿s “perspectivism”.

  10. Anticipation of direction and time of perturbation modulates the onset latency of trunk muscle responses during sitting perturbations.

    Science.gov (United States)

    Milosevic, Matija; Shinya, Masahiro; Masani, Kei; Patel, Kramay; McConville, Kristiina M V; Nakazawa, Kimitaka; Popovic, Milos R

    2016-02-01

    Trunk muscles are responsible for maintaining trunk stability during sitting. However, the effects of anticipation of perturbation on trunk muscle responses are not well understood. The objectives of this study were to identify the responses of trunk muscles to sudden support surface translations and quantify the effects of anticipation of direction and time of perturbation on the trunk neuromuscular responses. Twelve able-bodied individuals participated in the study. Participants were seated on a kneeling chair and support surface translations were applied in the forward and backward directions with and without direction and time of perturbation cues. The trunk started moving on average approximately 40ms after the perturbation. During unanticipated perturbations, average latencies of the trunk muscle contractions were in the range between 103.4 and 117.4ms. When participants anticipated the perturbations, trunk muscle latencies were reduced by 16.8±10.0ms and the time it took the trunk to reach maximum velocity was also reduced, suggesting a biomechanical advantage caused by faster muscle responses. These results suggested that trunk muscles have medium latency responses and use reflexive mechanisms. Moreover, anticipation of perturbation decreased trunk muscles latencies, suggesting that the central nervous system modulated readiness of the trunk based on anticipatory information. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Recovery from the most profound mass extinction of all time.

    Science.gov (United States)

    Sahney, Sarda; Benton, Michael J

    2008-04-07

    The end-Permian mass extinction, 251 million years (Myr) ago, was the most devastating ecological event of all time, and it was exacerbated by two earlier events at the beginning and end of the Guadalupian, 270 and 260 Myr ago. Ecosystems were destroyed worldwide, communities were restructured and organisms were left struggling to recover. Disaster taxa, such as Lystrosaurus, insinuated themselves into almost every corner of the sparsely populated landscape in the earliest Triassic, and a quick taxonomic recovery apparently occurred on a global scale. However, close study of ecosystem evolution shows that true ecological recovery was slower. After the end-Guadalupian event, faunas began rebuilding complex trophic structures and refilling guilds, but were hit again by the end-Permian event. Taxonomic diversity at the alpha (community) level did not recover to pre-extinction levels; it reached only a low plateau after each pulse and continued low into the Late Triassic. Our data showed that though there was an initial rise in cosmopolitanism after the extinction pulses, large drops subsequently occurred and, counter-intuitively, a surprisingly low level of cosmopolitanism was sustained through the Early and Middle Triassic.

  12. Time dependency of morphological remodeling of endothelial cells in response to substrate stiffness

    Science.gov (United States)

    Goli-Malekabadi, Zahra; Tafazzoli-shadpour, Mohammad; Tamayol, Ali; Seyedjafari, Ehsan

    2017-01-01

    Introduction: Substrate stiffness regulates cellular behavior as cells experience different stiffness values of tissues in the body. For example, endothelial cells (ECs) covering the inner layer of blood vessels are exposed to different stiffness values due to various pathologic and physiologic conditions. Despite numerous studies, cells by time span sense mechanical properties of the substrate, but the response is not well understood. We hypothesized that time is a major determinant influencing the behavior of cells seeded on substrates of varying stiffness. Methods: We monitored cell spreading, internal structure, 3D topography, and the viability of ECs over 24 hours of culture on polydimethylsiloxane (PDMS) substrates with two different degrees of elastic modulus. Results: Despite significant differences in cell spreading after cell seeding, cells showed a similar shape and internal structure after 24 hours of culture on both soft and stiff substrates. However, 3D topographical images confirmed existence of rich lamellipodia and filopodia around the cells cultured on stiffer PDMS substrates. Conclusion: It was concluded that the response of ECs to the substrate stiffness was time dependent with initial enhanced cellular spreading and viability on stiffer substrates. Results can provide a better comprehension of cell mechanotransduction for tissue engineering applications. PMID:28546952

  13. Study on time response character for high pressure gas ionization chamber of krypton and xenon

    International Nuclear Information System (INIS)

    Tan Chunming; Wu Haifeng; Qing Shangyu; Wang Liqiang

    2006-01-01

    The time response character for Kr and Xe high pressure gas ionization chamber is analyzed and deduced. Compared with the measure data of pulse rising time for three gas-filled ionization chambers, the calculated and experimental results are equal to each other. The rising time less than 10 ms for this kind of ionization chamber can be achieved, so this ionization chamber is able to meet the requirement for imaging detection. (authors)

  14. How can streamflow and climate-landscape data be used to estimate baseflow mean response time?

    Science.gov (United States)

    Zhang, Runrun; Chen, Xi; Zhang, Zhicai; Soulsby, Chris; Gao, Man

    2018-02-01

    Mean response time (MRT) is a metric describing the propagation of catchment hydraulic behavior that reflects both hydro-climatic conditions and catchment characteristics. To provide a comprehensive understanding of catchment response over a longer-time scale for hydraulic processes, the MRT function for baseflow generation was derived using an instantaneous unit hydrograph (IUH) model that describes the subsurface response to effective rainfall inputs. IUH parameters were estimated based on the "match test" between the autocorrelation function (ACFs) derived from the filtered base flow time series and from the IUH parameters, under the GLUE framework. Regionalization of MRT was conducted using estimates and hydroclimate-landscape indices in 22 sub-basins of the Jinghe River Basin (JRB) in the Loess Plateau of northwest China. Results indicate there is strong equifinality in determination of the best parameter sets but the median values of the MRT estimates are relatively stable in the acceptable range of the parameters. MRTs vary markedly over the studied sub-basins, ranging from tens of days to more than a year. Climate, topography and geomorphology were identified as three first-order controls on recharge-baseflow response processes. Human activities involving the cultivation of permanent crops may elongate the baseflow MRT and hence increase the dynamic storage. Cross validation suggests the model can be used to estimate MRTs in ungauged catchments in similar regions of throughout the Loess Plateau. The proposed method provides a systematic approach for MRT estimation and regionalization in terms of hydroclimate and catchment characteristics, which is helpful in the sustainable water resources utilization and ecological protection in the Loess Plateau.

  15. Sequential double excitations from linear-response time-dependent density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Mosquera, Martín A.; Ratner, Mark A.; Schatz, George C., E-mail: g-schatz@northwestern.edu [Department of Chemistry, Northwestern University, 2145 Sheridan Rd., Evanston, Illinois 60208 (United States); Chen, Lin X. [Department of Chemistry, Northwestern University, 2145 Sheridan Rd., Evanston, Illinois 60208 (United States); Chemical Sciences and Engineering Division, Argonne National Laboratory, 9700 South Cass Ave., Lemont, Illinois 60439 (United States)

    2016-05-28

    Traditional UV/vis and X-ray spectroscopies focus mainly on the study of excitations starting exclusively from electronic ground states. However there are many experiments where transitions from excited states, both absorption and emission, are probed. In this work we develop a formalism based on linear-response time-dependent density functional theory to investigate spectroscopic properties of excited states. We apply our model to study the excited-state absorption of a diplatinum(II) complex under X-rays, and transient vis/UV absorption of pyrene and azobenzene.

  16. Evolution of peripheral vs metabolic perfusion parameters during septic shock resuscitation. A clinical-physiologic study

    NARCIS (Netherlands)

    Hernandez, Glenn; Pedreros, Cesar; Veas, Enrique; Bruhn, Alejandro; Romero, Carlos; Rovegno, Maximiliano; Neira, Rodolfo; Bravo, Sebastian; Castro, Ricardo; Kattan, Eduardo; Ince, Can

    2012-01-01

    Purpose: Perfusion assessment during septic shock resuscitation is difficult and usually complex determinations. Capillary refill time (CRT) and central-to-toe temperature difference (Tc-toe) have been proposed as objective reproducible parameters to evaluate peripheral perfusion. The comparative

  17. Relationship Between Emergency Medical Services Response Time and Bystander Intervention in Patients With Out-of-Hospital Cardiac Arrest.

    Science.gov (United States)

    Goto, Yoshikazu; Funada, Akira; Goto, Yumiko

    2018-04-27

    The response time of emergency medical services (EMS) is an important determinant of survival after out-of-hospital cardiac arrest. We sought to identify upper limits of EMS response times and bystander interventions associated with neurologically intact survival. We analyzed the records of 553 426 patients with out-of-hospital cardiac arrest in a Japanese registry between 2010 and 2014. The primary study end point was 1-month neurologically intact survival (Cerebral Performance Category scale 1 or 2). Increased EMS response time was associated with significantly decreased adjusted odds of 1-month neurologically intact survival (adjusted odds ratio [aOR] for each 1-minute increase, 0.89; 95% confidence interval [CI], 0.89-0.90), although this relationship was modified by bystander interventions. The bystander interventions and the ranges of EMS response times that were associated with increased adjusted 1-month neurologically intact survival were as follows: bystander defibrillation, from ≤2 minutes (aOR, 3.10 [95% CI, 1.25-7.31]) to 13 minutes (aOR, 5.55 [95% CI, 2.66-11.2]); bystander conventional cardiopulmonary resuscitation, from 3 minutes (aOR 1.48 [95% CI, 1.02-2.12]) to 11 minutes (aOR 2.41 [95% CI, 1.61-3.56]); and bystander chest-compression-only cardiopulmonary resuscitation, from ≤2 minutes (aOR 1.57 [95% CI, 1.01-2.25]) to 11 minutes (aOR 1.92 [95% CI, 1.45-2.56]). However, the increase in neurologically intact survival of those receiving bystander interventions became statistically insignificant compared with no bystander interventions when the EMS response time was outside these ranges. The upper limits of the EMS response times associated with improved 1-month neurologically intact survival were 13 minutes when bystanders provided defibrillation (typically with cardiopulmonary resuscitation) and 11 minutes when bystanders provided cardiopulmonary resuscitation without defibrillation. © 2018 The Authors. Published on behalf of the

  18. Time Analysis of Building Dynamic Response Under Seismic Action. Part 1: Theoretical Propositions

    Science.gov (United States)

    Ufimtcev, E. M.

    2017-11-01

    The first part of the article presents the main provisions of the analytical approach - the time analysis method (TAM) developed for the calculation of the elastic dynamic response of rod structures as discrete dissipative systems (DDS) and based on the investigation of the characteristic matrix quadratic equation. The assumptions adopted in the construction of the mathematical model of structural oscillations as well as the features of seismic forces’ calculating and recording based on the data of earthquake accelerograms are given. A system to resolve equations is given to determine the nodal (kinematic and force) response parameters as well as the stress-strain state (SSS) parameters of the system’s rods.

  19. Response time scores on a reflexive attention task predict a child's inattention score from a parent report.

    Science.gov (United States)

    Lundwall, Rebecca A; Sgro, Jordan F; Fanger, Julia

    2018-01-01

    Compared to sustained attention, only a small proportion of studies examine reflexive attention as a component of everyday attention. Understanding the significance of reflexive attention to everyday attention may inform better treatments for attentional disorders. Children from a general population (recruited when they were from 9-16 years old) completed an exogenously-cued task measuring the extent to which attention is captured by peripheral cue-target conditions. Parents completed a questionnaire reporting their child's day-to-day attention. A general linear model indicated that parent-rated inattention predicted the increase in response time over baseline when a bright cue preceded the target (whether it was valid or invalid) but not when a dim cue preceded the target. More attentive children had more pronounced response time increases from baseline. Our findings suggest a link between a basic measure of cognition (response time difference scores) and parent observations. The findings have implications for increased understanding of the role of reflexive attention in the everyday attention of children.

  20. Optimal Load Response to Time-of-Use Power Price for Demand Side Management in Denmark

    DEFF Research Database (Denmark)

    Hu, Weihao; Chen, Zhe; Bak-Jensen, Birgitte

    2010-01-01

    -of-use power price for demand side management in order to save the energy costs as much as possible. 3 typical different kinds of loads (industrial load, residential load and commercial load) in Denmark are chosen as study cases. The energy costs decrease up to 9.6% with optimal load response to time......-of-use power price for different loads. Simulation results show that the optimal load response to time-of-use power price for demand side management generates different load profiles and reduces the load peaks. This kind of load patterns may also have significant effects on the power system normal operation.......Since the hourly spot market price is available one day ahead in Denmark, the price could be transferred to the consumers and they may shift their loads from high price periods to the low price periods in order to save their energy costs. This paper presents a load optimization method to time...

  1. Attention, spatial integration, and the tail of response time distributions in Stroop task performance

    NARCIS (Netherlands)

    Roelofs, A.P.A.

    2012-01-01

    A few studies have examined selective attention in Stroop task performance through ex-Gaussian analyses of response time (RT) distributions. It has remained unclear whether the tail of the RT distribution in vocal responding reflects spatial integration of relevant and irrelevant attributes, as

  2. Analytical solution of transient temperature in continuous wave end-pumped laser slab: Reduction of temperature distribution and time of thermal response

    Directory of Open Access Journals (Sweden)

    Shibib Khalid S.

    2017-01-01

    Full Text Available An analytical solution of transient 3-D heat equation based on integral transform method is derived. The result are compared with numerical solution, and good agreements are obtained. Minimization of response time and temperature distribution through a laser slab are tested. It is found that the increasing in the lateral convection heat transfer coefficient can significantly reduce the response time and the temperature distribution while no effect on response time is observed when changing pumping profile from Gaussian to top hat beam in spite of the latter reduce the temperature distribution, also it is found that dividing the pumping power between two slab ends might reduce the temperature distribution and it has no effect on thermal response time.

  3. Measurement of detector neutron energy response using time-of-flight techniques

    International Nuclear Information System (INIS)

    Janee, H.S.

    1973-09-01

    The feasibility of using time-of-flight techniques at the EG and G/AEC linear accelerator for measuring the neutron response of relatively sensitive detectors over the energy range 0.5 to 14 MeV has been demonstrated. The measurement technique is described in detail as are the results of neutron spectrum measurements from beryllium and uranium photoneutron targets. The sensitivity of a fluor photomultiplier LASL detector with a 2- by 1-inch NE-111 scintillator was determined with the two targets, and agreement in the region of overlap was very good. (U.S.)

  4. The influence of social support and perceived stress on response time inconsistency.

    Science.gov (United States)

    Phibbs, Sandi; Stawski, Robert S; MacDonald, Stuart W S; Munoz, Elizabeth; Smyth, Joshua M; Sliwinski, Martin J

    2017-11-24

    Lack of social support and high levels of stress represent potentially modifiable risk factors for cognitive aging. In this study we examined the relationships between these two risk factors and response time inconsistency (RTI), or trial-to-trial variability in choice response time tasks. RTI is an early indicator of declining cognitive health, and examining the influence of modifiable psychosocial risk factors on RTI is important for understanding and promoting cognitive health during adulthood and old age. Using data from a community sample study (n = 317; M age = 49, range = 19-83), we examined the effects of social support, including size of network and satisfaction with support, global perceived stress, and their interactions on RTI. Neither size of network nor satisfaction with support was associated with RTI independent of perceived stress. Stress was positively associated with increased RTI on all tasks, independent of social support. Perceived stress did not interact with either dimension of social support to predict RTI, and perceived stress effects were invariant across age and sex. Perceived stress, but not social support, may be a unique and modifiable risk factor for normal and pathological cognitive aging. Discussion focuses on the importance of perceived stress and its impact on RTI in supporting cognitive health in adulthood and old age.

  5. On The Settling And Response Times Of Underdamped Second-Order Systems

    Directory of Open Access Journals (Sweden)

    Abdul-Fattah Mohamed Ali

    2012-01-01

    Full Text Available The normalized settling time (ts/t values of oscillatory second order systems, when subjected to a step-change forcing function (SCFF, depend on the sensitivity of the measuring instrument employed to indicate the response (± x%. An attempt is made to mathematically relate ts/t to ± x% utilizing the exact, and a simplified, expression for the lower boundary of the decay envelope (LBDE. The two obtained relationships were tested against the actual ts/t values for a settling bands range of ±1% = ±x% = ±6%, covering a damping coefficient range of 0.1 = ? = 0.65. Although the relationships are not exact, their general trend is a marginal overestimation of ts/t. The relationship based on the simplified LBDE was chosen for being simpler and slightly more accurate of the two. This led to a suggested distinction between ts/t and the normalized response time (tR/t, with the latter assigned the value 5/ ? . The ratio ts/tR can thus be readily established for any ± x% value.ABSTRAK: Masa enapan ternormal (ts/t  nilai ayunan system terbit kedua, apabila fungsi memaksa ubah berperingkat (step-change forcing function (SCFF dijalankan ke atasnya, bergantung kepada kepekaan alat pengukur yang digunakan untuk mengukur respons (± x%. Satu percubaan dijalankan secara matematik untuk mengaitkan ts/t to ± x% dengan mempergunakan ekspresi yang tepat dan mudah, pada sempadan bawah sampul reputan (lower boundary of the decay envelope (LBDE. Dua hubungan yang diperolehi dikaji terhadap nilai ts/t sebenar untuk julat jalur enapan ±1% = ±x% = ±6%, melingkungi julat pekali redaman 0.1 = ? = 0.65. Walaupun hubungannya tidak tepat, trend umum merupakan penganggaran marginal ts/t. Hubungan berdasarkan LBDE adalah berdasarkan  LBDE yang telah dipermudahkan, ia dipilih kerana ianya senang dan agak tepat antara keduanya. Ini mendorong kepada perbezaan yang disarankan antara ts/t  dan waktu respons ternormal (tR/t, dengan nilai 5/ ? yang ditetapkan kemudiannya

  6. Transformation of binaural response properties in the ascending auditory pathway: influence of time-varying interaural phase disparity.

    Science.gov (United States)

    Spitzer, M W; Semple, M N

    1998-12-01

    Transformation of binaural response properties in the ascending auditory pathway: influence of time-varying interaural phase disparity. J. Neurophysiol. 80: 3062-3076, 1998. Previous studies demonstrated that tuning of inferior colliculus (IC) neurons to interaural phase disparity (IPD) is often profoundly influenced by temporal variation of IPD, which simulates the binaural cue produced by a moving sound source. To determine whether sensitivity to simulated motion arises in IC or at an earlier stage of binaural processing we compared responses in IC with those of two major IPD-sensitive neuronal classes in the superior olivary complex (SOC), neurons whose discharges were phase locked (PL) to tonal stimuli and those that were nonphase locked (NPL). Time-varying IPD stimuli consisted of binaural beats, generated by presenting tones of slightly different frequencies to the two ears, and interaural phase modulation (IPM), generated by presenting a pure tone to one ear and a phase modulated tone to the other. IC neurons and NPL-SOC neurons were more sharply tuned to time-varying than to static IPD, whereas PL-SOC neurons were essentially uninfluenced by the mode of stimulus presentation. Preferred IPD was generally similar in responses to static and time-varying IPD for all unit populations. A few IC neurons were highly influenced by the direction and rate of simulated motion, but the major effect for most IC neurons and all SOC neurons was a linear shift of preferred IPD at high rates-attributable to response latency. Most IC and NPL-SOC neurons were strongly influenced by IPM stimuli simulating motion through restricted ranges of azimuth; simulated motion through partially overlapping azimuthal ranges elicited discharge profiles that were highly discontiguous, indicating that the response associated with a particular IPD is dependent on preceding portions of the stimulus. In contrast, PL-SOC responses tracked instantaneous IPD throughout the trajectory of simulated

  7. Time course transcriptome changes in Shewanella algae in response to salt stress.

    Directory of Open Access Journals (Sweden)

    Xiuping Fu

    Full Text Available Shewanella algae, which produces tetrodotoxin and exists in various seafoods, can cause human diseases, such as spondylodiscitis and bloody diarrhea. In the present study, we focused on the temporal, dynamic process in salt-stressed S. algae by monitoring the gene transcript levels at different time points after high salt exposure. Transcript changes in amino acid metabolism, carbohydrate metabolism, energy metabolism, membrane transport, regulatory functions, and cellular signaling were found to be important for the high salt response in S. algae. The most common strategies used by bacteria to survive and grow in high salt environments, such as Na+ efflux, K+ uptake, glutamate transport and biosynthesis, and the accumulation of compatible solutes, were also observed in S. algae. In particular, genes involved in peptidoglycan biosynthesis and DNA repair were highly and steadily up-regulated, accompanied by rapid and instantaneous enhancement of the transcription of large- and small-ribosome subunits, which suggested that the structural changes in the cell wall and some stressful responses occurred in S. algae. Furthermore, the transcription of genes involved in the tricarboxylic acid (TCA cycle and the glycolytic pathway was decreased, whereas the transcription of genes involved in anaerobic respiration was increased. These results, demonstrating the multi-pathway reactions of S. algae in response to salt stress, increase our understanding of the microbial stress response mechanisms.

  8. Regional changes over time in initial virologic response rates to combination antiretroviral therapy across Europe

    DEFF Research Database (Denmark)

    Bannister, Wendy P; Kirk, Ole; Gatell, Jose M

    2006-01-01

    : Virologic response (viral load SIDA patients. Analyses were stratified by region (south, central west, north, east) or time started cART (early, 1996-1997; mid, 1998-1999; late, 2000-1904). RESULTS: Virologic...

  9. Regional changes over time in initial virological response rates to combination antiretroviral therapy across Europe

    DEFF Research Database (Denmark)

    Bannister, W; Kirk, O; Gatell, J

    2006-01-01

    : Virologic response (viral load SIDA patients. Analyses were stratified by region (south, central west, north, east) or time started cART (early, 1996-1997; mid, 1998-1999; late, 2000-1904). RESULTS: Virologic...

  10. Quantitative analysis of biological responses to low dose-rate γ-radiation, including dose, irradiation time, and dose-rate

    International Nuclear Information System (INIS)

    Magae, J.; Furukawa, C.; Kawakami, Y.; Hoshi, Y.; Ogata, H.

    2003-01-01

    Full text: Because biological responses to radiation are complex processes dependent on irradiation time as well as total dose, it is necessary to include dose, dose-rate and irradiation time simultaneously to predict the risk of low dose-rate irradiation. In this study, we analyzed quantitative relationship among dose, irradiation time and dose-rate, using chromosomal breakage and proliferation inhibition of human cells. For evaluation of chromosome breakage we assessed micronuclei induced by radiation. U2OS cells, a human osteosarcoma cell line, were exposed to gamma-ray in irradiation room bearing 50,000 Ci 60 Co. After the irradiation, they were cultured for 24 h in the presence of cytochalasin B to block cytokinesis, cytoplasm and nucleus were stained with DAPI and propidium iodide, and the number of binuclear cells bearing micronuclei was determined by fluorescent microscopy. For proliferation inhibition, cells were cultured for 48 h after the irradiation and [3H] thymidine was pulsed for 4 h before harvesting. Dose-rate in the irradiation room was measured with photoluminescence dosimeter. While irradiation time less than 24 h did not affect dose-response curves for both biological responses, they were remarkably attenuated as exposure time increased to more than 7 days. These biological responses were dependent on dose-rate rather than dose when cells were irradiated for 30 days. Moreover, percentage of micronucleus-forming cells cultured continuously for more than 60 days at the constant dose-rate, was gradually decreased in spite of the total dose accumulation. These results suggest that biological responses at low dose-rate, are remarkably affected by exposure time, that they are dependent on dose-rate rather than total dose in the case of long-term irradiation, and that cells are getting resistant to radiation after the continuous irradiation for 2 months. It is necessary to include effect of irradiation time and dose-rate sufficiently to evaluate risk

  11. Motivational changes in response to blocked goals and foreshortened time: testing alternatives to socioemotional selectivity theory.

    Science.gov (United States)

    Fung, Helene H; Carstensen, Laura L

    2004-03-01

    Socioemotional selectivity theory contends that when people perceive time as limited, they prioritize emotionally meaningful goals. Although empirical support for the theory has been found in several studies, 2 alternative explanations for the pattern of findings remain: (a) emotional goals are pursued by default because nonemotional goals are blocked, and (b) emotional goals are pursued in search of emotional support rather than emotional meaning. This study tested these alternatives by examining social goals in response to blocked goals and foreshortened time. Findings reveal distinct motivational patterns, as reflected in social preferences and self-reported social goals, in response to the 2 types of constraints.

  12. The Responsibility Of Trade Unions In Transaction Collective Instruments About Compensatory Time

    OpenAIRE

    Manuella de Oliveira Soares; Rui Carvalho Piva

    2016-01-01

    The democratic State of Direct aims to provide assurance and effectiveness of fundamental rights in order that human dignity is preserved. In this way, among other fundamental rights is the right to health, in one of its aspects, protects workers' health. Thus, this study, through a bibliographical research aims to demonstrate that unions should be held responsible for damage caused to workers when preparing collective bargaining instruments to the creation of compensatory time with condition...

  13. Predicting macropores in space and time by earthworms and abiotic controls

    Science.gov (United States)

    Hohenbrink, Tobias Ludwig; Schneider, Anne-Kathrin; Zangerlé, Anne; Reck, Arne; Schröder, Boris; van Schaik, Loes

    2017-04-01

    Macropore flow increases infiltration and solute leaching. The macropore density and connectivity, and thereby the hydrological effectiveness, vary in space and time due to earthworms' burrowing activity and their ability to refill their burrows in order to survive drought periods. The aim of our study was to predict the spatiotemporal variability of macropore distributions by a set of potentially controlling abiotic variables and abundances of different earthworm species. We measured earthworm abundances and effective macropore distributions using tracer rainfall infiltration experiments in six measurement campaigns during one year at six field sites in Luxembourg. Hydrologically effective macropores were counted in three soil depths (3, 10, 30 cm) and distinguished into three diameter classes (6 mm). Earthworms were sampled and determined to species-level. In a generalized linear modelling framework, we related macropores to potential spatial and temporal controlling factors. Earthworm species such as Lumbricus terrestris and Aporrectodea longa, local abiotic site conditions (land use, TWI, slope), temporally varying weather conditions (temperature, humidity, precipitation) and soil moisture affected the number of effective macropores. Main controlling factors and explanatory power of the models (uncertainty and model performance) varied depending on the depth and diameter class of macropores. We present spatiotemporal predictions of macropore density by daily-resolved, one year time series of macropore numbers and maps of macropore distributions at specific dates in a small-scale catchment with 5 m resolution.

  14. The prognostic value of the subjective assessment of peripheral perfusion in critically ill patients

    NARCIS (Netherlands)

    Lima, Alexandre; Jansen, Tim C.; van Bommel, Jasper; Ince, Can; Bakker, Jan

    2009-01-01

    OBJECTIVE:: The physical examination of peripheral perfusion based on touching the skin or measuring capillary refill time has been related to the prognosis of patients with circulatory shock. It is unclear, however, whether monitoring peripheral perfusion after initial resuscitation still provides

  15. Real-time Holographic Display Based on a Super Fast Response Thin Film

    International Nuclear Information System (INIS)

    Gao, Hongyue; Li, Xiao; He, Zhenghong; Su, Yikai; Poon, Ting-Chung

    2013-01-01

    Real-time dynamic holographic display is obtained with super fast response in a thin film without any applied electric field. Holograms can be refreshed in the order of a millisecond and there is no cross talk between the recorded holograms because the hologram formed in the film is transient and can be completely self erased, and the hologram formation time and self-erasure time are both ∼1 ms. Holographic video display is achieved, which shows the real-time holographic image display capability of the thin film, and its much higher resolution than those of commercially available spatial light modulators. Furthermore, multiplexed hologram display using two polarization directions of a recorded light and multiple color holographic display at different laser wavelengths are presented, which demonstrate the feasibility of a RGB color holographic three-dimensional display with the thin film. Because the sample is easy to be fabricated into a large size screen and needs no external applied electric field, we think that the film can be developed into a large-size, dynamic, and color holographic three-dimensional display in the future.

  16. 1H NMR-based metabolomics of time-dependent responses of Eisenia fetida to sub-lethal phenanthrene exposure

    International Nuclear Information System (INIS)

    Lankadurai, Brian P.; Wolfe, David M.; Simpson, Andre J.; Simpson, Myrna J.

    2011-01-01

    1 H NMR-based metabolomics was used to examine the response of the earthworm Eisenia fetida after exposure to sub-lethal concentrations of phenanthrene over time. Earthworms were exposed to 0.025 mg/cm 2 of phenanthrene (1/64th of the LC 50 ) via contact tests over four days. Earthworm tissues were extracted using a mixture of chloroform, methanol and water, resulting in polar and non-polar fractions that were analyzed by 1 H NMR after one, two, three and four days. NMR-based metabolomic analyses revealed heightened E. fetida responses with longer phenanthrene exposure times. Amino acids alanine and glutamate, the sugar maltose, the lipids cholesterol and phosphatidylcholine emerged as potential indicators of phenanthrene exposure. The conversion of succinate to fumarate in the Krebs cycle was also interrupted by phenanthrene. Therefore, this study shows that NMR-based metabolomics is a powerful tool for elucidating time-dependent relationships in addition to the mode of toxicity of phenanthrene in earthworm exposure studies. - Highlights: → NMR-based earthworm metabolomic analysis of the mode of action of phenanthrene is presented. → The earthworm species E. fetida were exposed to sub-lethal phenanthrene concentrations. → Both polar and non-polar metabolites of E. fetida tissue extracts were analyzed by 1 H NMR. → Longer phenanthrene exposure times resulted in heightened earthworm responses. → An interruption of the Krebs cycle was also observed due to phenanthrene exposure. - 1 H NMR metabolomics is used to determine the relationship between phenanthrene exposure and the metabolic response of the earthworm E. fetida over time and also to elucidate the phenanthrene mode of toxicity.

  17. The effects of pre-etching time on the characteristic responses of electrochemically etched CR-39 neutron dosimeters

    International Nuclear Information System (INIS)

    Sohrabi, M.; Khoshnoodi, M.

    1986-01-01

    The effects of pre-etching time (PET) or duration of etching of fast-neutron-induced-recoil tracks in CR-39 in 6N KOH at 60 0 C on electrochemical etching neutron characteristic responses; i.e. sensitivity and mean recoil track diameter (MRTD) versus KOH normality up to 18N are investigated in this paper. Six sets of responses for PETs of 0, 1, 2, 3, 4, and 5 hours were obtained by using our new multi-chamber ECE (MCECE) system which reduced total operation time to about 6% of the time usually required when single-chamber ECE systems are used. The sensitivity response for zero PET showed a broad plateau and a high sensitivity low-LET peak around 16N. By increasing PET, another peak was also developed around 5N leading to 'double-humped' responses with two maximums around 5N and 16N, and a minimum around 11N. On the other hand, the MRTD responses for all PETs studied showed the same general trend with maximums around 11N. In this paper, shape of tracks under different conditions are also investigated, new optimum conditions such as KOH concentrations of 5, 11, and 15N at 25 0 C, with or without pre-etching, are recommended for tracks of lower-LET recoils including possibly protons, and alpha particle tracks over a broad energy range, and the efficiency of the MCECE system is also demonstrated. (author)

  18. Electromagnetic velocity gauge: use of multiple gauges, time response, and flow perturbations

    International Nuclear Information System (INIS)

    Erickson, L.M.; Johnson, C.B.; Parker, N.L.; Vantine, H.C.; Weingart, R.C.; Lee, R.S.

    1981-01-01

    We have developed an in-situ electromagnetic velocity (EMV) gauge system for use in multiple-gauge studies of initiating and detonating explosives. We have also investigated the risetime of the gauge and the manner in which it perturbs a reactive flow. We report on the special precautions that are necessary in multiple gauge experiments to reduce lead spreading, simplify target fabrication problems and minimize cross talk through the conducting explosive. Agreement between measured stress records and calculations from multiple velocity gauge data give us confidence that our velocity gauges are recording properly. We have used laser velocity interferometry to measure the gauge risetime in polymethyl methacrylate (PMMA). To resolve the difference in the two methods, we have examined hydrodynamic and material rate effects. In addition, we considered the effects of shock tilt, electronic response and magntic diffusion on the gauge's response time

  19. Advances in real-time technology assessment and emergency response: Close-in atmospheric dispersion modeling and exposure estimation

    International Nuclear Information System (INIS)

    Sims, J.; Lee, R.; McCallen, R.; Lawver, B.; Clark, J.; Rueppel, D.; Sullivan, T.

    1992-07-01

    We have developed a stand-alone, real-time emergency response system to assess and predict the offsite dispersion of particulate releases. We have also developed advanced modeling tools that win expand the capability of the emergency response system to predict nearfield dispersion over complex terrain and around buildings

  20. Measurement and deconvolution of detector response time for short HPM pulses: Part 1, Microwave diodes

    International Nuclear Information System (INIS)

    Bolton, P.R.

    1987-06-01

    A technique is described for measuring and deconvolving response times of microwave diode detection systems in order to generate corrected input signals typical of an infinite detection rate. The method has been applied to cases of 2.86 GHz ultra-short HPM pulse detection where pulse rise time is comparable to that of the detector; whereas, the duration of a few nanoseconds is significantly longer. Results are specified in terms of the enhancement of equivalent deconvolved input voltages for given observed voltages. The convolution integral imposes the constraint of linear detector response to input power levels. This is physically equivalent to the conservation of integrated pulse energy in the deconvolution process. The applicable dynamic range of a microwave diode is therefore limited to a smaller signal region as determined by its calibration

  1. Metabolic Responses and Pacing Strategies during Successive Sprint Skiing Time Trials

    DEFF Research Database (Denmark)

    Andersson, Erik; Holmberg, Hans-Christer; Ørtenblad, Niels

    2016-01-01

    PURPOSE: To examine the metabolic responses and pacing strategies during the performance of successive sprint time trials (STTs) in cross-country skiing. METHODS: Ten well-trained male cross-country skiers performed four self-paced 1300-m STTs on a treadmill, each separated by 45 min of recovery...... to estimate the anaerobic energy supply. RESULTS: The individual trial-to-trial variability in STT performance time was 1.3%, where variations in O2 deficit and V˙O2 explained 69% (P 0.05) of the variation in performance. The first and last STTs were equally fast (228 ± 10 s), and ~ 1...... on the first than second course half. In addition, metabolic rates were substantially higher (~_30%) for uphill than for flat skiing, indicating that pacing was regulated to the terrain. CONCLUSIONS: The fastest STTs were characterized primarily by a greater anaerobic energy production, which also explained 69...

  2. USGS Provision of Near Real Time Remotely Sensed Imagery for Emergency Response

    Science.gov (United States)

    Jones, B. K.

    2014-12-01

    The use of remotely sensed imagery in the aftermath of a disaster can have an important impact on the effectiveness of the response for many types of disasters such as floods, earthquakes, volcanic eruptions, landslides, and other natural or human-induced disasters. Ideally, responders in areas that are commonly affected by disasters would have access to archived remote sensing imagery plus the ability to easily obtain the new post event data products. The cost of obtaining and storing the data and the lack of trained professionals who can process the data into a mapping product oftentimes prevent this from happening. USGS Emergency Operations provides remote sensing and geospatial support to emergency managers by providing access to satellite images from numerous domestic and international space agencies including those affiliated with the International Charter Space and Major Disasters and their space-based assets and by hosting and distributing thousands of near real time event related images and map products through the Hazards Data Distribution System (HDDS). These data may include digital elevation models, hydrographic models, base satellite images, vector data layers such as roads, aerial photographs, and other pre and post disaster data. These layers are incorporated into a Web-based browser and data delivery service, the Hazards Data Distribution System (HDDS). The HDDS can be made accessible either to the general public or to specific response agencies. The HDDS concept anticipates customer requirements and provides rapid delivery of data and services. This presentation will provide an overview of remotely sensed imagery that is currently available to support emergency response operations and examples of products that have been created for past events that have provided near real time situational awareness for responding agencies.

  3. Timing and duration of omalizumab response in patients with chronic idiopathic/spontaneous urticaria.

    Science.gov (United States)

    Kaplan, Allen; Ferrer, Marta; Bernstein, Jonathan A; Antonova, Evgeniya; Trzaskoma, Benjamin; Raimundo, Karina; Rosén, Karin; Omachi, Theodore A; Khalil, Sam; Zazzali, James L

    2016-02-01

    Few data are available that describe response patterns in patients with chronic idiopathic urticaria (CIU)/chronic spontaneous urticaria (CSU) treated with omalizumab. We sought to describe response patterns by using data from the 3 pivotal omalizumab CIU/CSU trials. Every 4 weeks, randomized patients received dosing with placebo or 75, 150, or 300 mg of omalizumab (ASTERIA I: n = 318, 24 weeks; ASTERIA II: n = 322, 12 weeks) or placebo or 300 mg of omalizumab (GLACIAL: n = 335, 24 weeks). Response was defined as well-controlled urticaria (weekly Urticaria Activity Score [UAS7] ≤ 6) or complete response (UAS7 = 0). Response rates were dose dependent and highest with 300 mg of omalizumab. Some patients responded early (before week 4). At week 12, a higher proportion of patients treated with 300 mg of omalizumab reported a UAS7 ≤ 6 (26.0% [75 mg of omalizumab], 40.0% [150 mg of omalizumab], 51.9% [300 mg of omalizumab], and 11.3% [placebo] for ASTERIA I; 26.8% [75 mg of omalizumab], 42.7% [150 mg of omalizumab], 65.8% [300 mg of omalizumab], and 19.0% [placebo] for ASTERIA II; and 52.4% [300 mg of omalizumab] and 12.0% [placebo] for GLACIAL) or a UAS7 = 0 (11.7% [75 mg of omalizumab], 15.0% [150 mg of omalizumab], 35.8% [300 mg of omalizumab], and 8.8% [placebo] for ASTERIA I; 15.9% [75 mg of omalizumab], 22.0% [150 mg of omalizumab], 44.3% [300 mg of omalizumab], and 5.1% [placebo] for ASTERIA II; and 33.7% [300 mg of omalizumab] and 4.8% [placebo] for GLACIAL). In patients receiving 300 mg of omalizumab with 24 weeks of treatment, median time to achieve a UAS7 ≤ 6 was 6 weeks (ASTERIA I and GLACIAL) and median time to achieve a UAS7 = 0 was 12 or 13 weeks (ASTERIA I and GLACIAL, respectively). Some patients who achieved well-controlled urticaria or complete response sustained response throughout the treatment period. Benefits of omalizumab treatment were evident early (before week 4) in some patients and persisted to week

  4. Left ventricular time volume curve analysis in the detection of limited ischaemic heart disease

    International Nuclear Information System (INIS)

    Liechtenstein, M.; Blanchett, W.; Andrews, J.; Hunt, D.

    1982-01-01

    The aim of the study was to determine whether limited coronary artery disease (CAD) could be accurately detected using the Cardiac Gated Blood Pool (CGBP) scan with exercise. Regional left ventricular time volume curves (RLTVD) were generated from 52 studies (46 patients: 22 normals, 24 abnormals). The parameters assessed both globally and regionally and at rest (R) and exercise (Ex) were: (1) the ejection fraction (EF) (2) the change in ejection fraction from R to Ex (δEF) (3) an early contraction index (ECI) (4) a maximal emptying index (DR) and (5) a maximal refilling index (AR). After careful analysis of these parameters it was decided that our diagnostic criteria would rely on the following: (1) the EF at R and Ex (2) the δ EF (3) the ECI at Ex (4) the AR at Ex This study showed that both the sensitivity and the specificity of the CGBP scan can be improved considerably with the inclusion of RLTVC from the levels obtained when the EF parameters alone are considered. It is possible with this technique to accurately diagnose limited CAD. (Author)

  5. The effects of response cost and species-typical behaviors on a daily time-place learning task.

    Science.gov (United States)

    Deibel, Scott H; Thorpe, Christina M

    2013-03-01

    Two theories that have been hypothesized to mediate acquisition in daily time-place learning (TPL) tasks were investigated in a free operant daily TPL task: the response cost hypothesis and the species-typical behavior hypothesis. One lever at the end of one of the choice arms of a T-maze provided food in the morning, and 6 h later, a lever in the other choice arm provided food. Four groups were used to assess the effect of two possible sources of response cost: physical effort of the task and costs associated with foraging ecology. One group was used to assess the effect of explicitly allowing for species-typical behaviors. If only first arm choice data were considered, there was little evidence of learning. However, both first press and percentage of presses on the correct lever prior to the first reinforcement revealed evidence of TPL in most rats tested. Unexpectedly, the high response cost groups for both of the proposed sources did not perform better than the low response cost groups. The groups that allowed animals to display species-typical behaviors performed the worst. Skip session probe trials confirmed that the majority of the rats that acquired the task were using a circadian timing strategy. The results from the present study suggest that learning in free operant daily TPL tasks might not be dependent on response cost.

  6. Stress responsiveness and anxiety-like behavior: The early social environment differentially shapes stability over time in a small rodent.

    Science.gov (United States)

    Sangenstedt, Susanne; Jaljuli, Iman; Sachser, Norbert; Kaiser, Sylvia

    2017-04-01

    The early social environment can profoundly affect behavioral and physiological phenotypes. We investigated how male wild cavy offspring, whose mothers had either lived in a stable (SE) or an unstable social environment (UE) during pregnancy and lactation, differed in their anxiety-like behavior and stress responsiveness. At two different time points in life, we tested the offspring's anxiety-like behavior in a dark-light test and their endocrine reaction to challenge in a cortisol reactivity test. Furthermore, we analyzed whether individual traits remained stable over time. There was no effect of the early social environment on anxiety-like behavior and stress responsiveness. However, at an individual level, anxiety-like behavior was stable over time in UE- but not in SE-sons. Stress responsiveness, in turn, was rather inconsistent in UE-sons and temporally stable in SE-sons. Conclusively, we showed for the first time that the early social environment differentially shapes the stability of behavioral and endocrine traits. At first glance, these results may be surprising, but they can be explained by the different functions anxiety-like behavior and stress responsiveness have. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. The genomic response of Ishikawa cells to bisphenol A exposure is dose- and time-dependent

    International Nuclear Information System (INIS)

    Naciff, Jorge M.; Khambatta, Zubin S.; Reichling, Timothy D.; Carr, Gregory J.; Tiesman, Jay P.; Singleton, David W.; Khan, Sohaib A.; Daston, George P.

    2010-01-01

    A reliable in vitro model to determine the potential estrogenic activity of chemicals of interest is still unavailable. To further investigate the usefulness of a human-derived cell line, we determined the transcriptional changes induced by bisphenol A (BPA) in Ishikawa cells at various doses (1 nM, 100 nM, 10 μM, and 100 μM) and time points (8, 24 and 48 h) by comparing the response of approximately 38,500 human genes and ESTs between treatment groups and controls (vehicle-treated). By trend analysis, we determined that the expression of 2794 genes was modified by BPA in a dose- and time-dependent manner (p ≤ 0.0001). However, the majority of gene expression changes induced in Ishikawa cells were elicited by the highest doses of BPA evaluated (10-100 μM), while the genomic response of the cells exposed to low doses of BPA was essentially negligible. By comparing the Ishikawa cells' response to BPA vs.17α-ethynyl estradiol we determined that the change in the expression of 307 genes was identical in the direction of the change, although the magnitude of the change for some genes was different. Further, the response of Ishikawa cells to high doses of BPA shared similarities to the estrogenic response of the rat uterus, specifically, 362 genes were regulated in a similar manner in vivo as well as in vitro. Gene ontology analysis indicated that BPA results in changes to multiple molecular pathways affecting various biological processes particularly associated with cell organization and biogenesis, regulation of translation, cell proliferation, and intracellular transport; processes also affected by estrogen exposure in the uterus of the rat. These results indicate that Ishikawa cells are capable of generating a biologically relevant estrogenic response after exposure to chemicals with varied estrogenic activity, and offer an in vitro model to assess this mode of action.

  8. Professional Aspirations among Pre-Service Teachers: Personal Responsibility, Time Perspectives, and Career Choice Satisfaction

    Science.gov (United States)

    Eren, Altay

    2017-01-01

    Exploring the direct and indirect effects of pre-service teachers' sense of personal responsibility on their professional aspirations through affective (i.e., career choice satisfaction) and cognitive (i.e., time perspectives) variables may enable teacher educators and policy makers to better describe the factors influencing teacher development in…

  9. Impact of optimal load response to real-time electricity price on power system constraints in Denmark

    DEFF Research Database (Denmark)

    Hu, Weihao; Chen, Zhe; Bak-Jensen, Birgitte

    2010-01-01

    Since the hourly spot market price is available one day ahead in Denmark, the price could be transferred to the consumers and they may shift their loads from high price periods to the low price periods in order to save their energy costs. The optimal load response to a real-time electricity price...... and may represent the future of electricity markets in some ways, is chosen as the studied power system in this paper. A distribution system where wind power capacity is 126% of maximum loads is chosen as the study case. This paper presents a nonlinear load optimization method to real-time power price...... for demand side management in order to save the energy costs as much as possible. Simulation results show that the optimal load response to a real-time electricity price has some good impacts on power system constraints in a distribution system with high wind power penetrations....

  10. Conditional Dependence between Response Time and Accuracy: An Overview of its Possible Sources and Directions for Distinguishing between Them

    Science.gov (United States)

    Bolsinova, Maria; Tijmstra, Jesper; Molenaar, Dylan; De Boeck, Paul

    2017-01-01

    With the widespread use of computerized tests in educational measurement and cognitive psychology, registration of response times has become feasible in many applications. Considering these response times helps provide a more complete picture of the performance and characteristics of persons beyond what is available based on response accuracy alone. Statistical models such as the hierarchical model (van der Linden, 2007) have been proposed that jointly model response time and accuracy. However, these models make restrictive assumptions about the response processes (RPs) that may not be realistic in practice, such as the assumption that the association between response time and accuracy is fully explained by taking speed and ability into account (conditional independence). Assuming conditional independence forces one to ignore that many relevant individual differences may play a role in the RPs beyond overall speed and ability. In this paper, we critically consider the assumption of conditional independence and the important ways in which it may be violated in practice from a substantive perspective. We consider both conditional dependences that may arise when all persons attempt to solve the items in similar ways (homogeneous RPs) and those that may be due to persons differing in fundamental ways in how they deal with the items (heterogeneous processes). The paper provides an overview of what we can learn from observed conditional dependences. We argue that explaining and modeling these differences in the RPs is crucial to increase both the validity of measurement and our understanding of the relevant RPs. PMID:28261136

  11. Diabetic Driving Studies-Part 2: A Comparison of Brake Response Time Between Drivers With Diabetes With and Without Lower Extremity Sensorimotor Neuropathy.

    Science.gov (United States)

    Spiess, Kerianne E; Sansosti, Laura E; Meyr, Andrew J

    We have previously demonstrated an abnormally delayed mean brake response time and an increased frequency of abnormally delayed brake responses in a group of neuropathic drivers with diabetes compared with a control group of drivers with neither diabetes nor lower extremity neuropathy. The objective of the present case-control study was to compare the mean brake response time between 2 groups of drivers with diabetes with and without lower extremity sensorimotor neuropathy. The braking performances of the participants were evaluated using a computerized driving simulator with specific measurement of the mean brake response time and the frequency of the abnormally delayed brake responses. We compared a control group of 25 active drivers with type 2 diabetes without lower extremity neuropathy and an experimental group of 25 active drivers with type 2 diabetes and lower extremity neuropathy from an urban U.S. podiatric medical clinic. The experimental group demonstrated an 11.49% slower mean brake response time (0.757 ± 0.180 versus 0.679 ± 0.120 second; p time slower than a suggested safety threshold of 0.70 second, and diabetic drivers without neuropathy demonstrated a mean brake response time faster than this threshold. The results of the present investigation provide evidence that the specific onset of lower extremity sensorimotor neuropathy associated with diabetes appears to impart a negative effect on automobile brake responses. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Application of xCELLigence RTCA Biosensor Technology for Revealing the Profile and Window of Drug Responsiveness in Real Time

    Directory of Open Access Journals (Sweden)

    Dan Kho

    2015-04-01

    Full Text Available The xCELLigence technology is a real-time cellular biosensor, which measures the net adhesion of cells to high-density gold electrode arrays printed on custom-designed E-plates. The strength of cellular adhesion is influenced by a myriad of factors that include cell type, cell viability, growth, migration, spreading and proliferation. We therefore hypothesised that xCELLigence biosensor technology would provide a valuable platform for the measurement of drug responses in a multitude of different experimental, clinical or pharmacological contexts. In this manuscript, we demonstrate how xCELLigence technology has been invaluable in the identification of (1 not only if cells respond to a particular drug, but (2 the window of drug responsiveness. The latter aspect is often left to educated guess work in classical end-point assays, whereas biosensor technology reveals the temporal profile of the response in real time, which enables both acute responses and longer term responses to be profiled within the same assay. In our experience, the xCELLigence biosensor technology is suitable for highly targeted drug assessment and also low to medium throughput drug screening, which produces high content temporal data in real time.

  13. 78 FR 36550 - Proposed Data Collections Submitted for Public Comment and Recommendations

    Science.gov (United States)

    2013-06-18

    ... barriers to program implementation, solutions to those barriers, and documentation of client health... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention [60Day-13-13XA... prescription filling patterns and timing of refills, checking for medication interactions, patient education...

  14. The linear transformation model with frailties for the analysis of item response times.

    Science.gov (United States)

    Wang, Chun; Chang, Hua-Hua; Douglas, Jeffrey A

    2013-02-01

    The item response times (RTs) collected from computerized testing represent an underutilized source of information about items and examinees. In addition to knowing the examinees' responses to each item, we can investigate the amount of time examinees spend on each item. In this paper, we propose a semi-parametric model for RTs, the linear transformation model with a latent speed covariate, which combines the flexibility of non-parametric modelling and the brevity as well as interpretability of parametric modelling. In this new model, the RTs, after some non-parametric monotone transformation, become a linear model with latent speed as covariate plus an error term. The distribution of the error term implicitly defines the relationship between the RT and examinees' latent speeds; whereas the non-parametric transformation is able to describe various shapes of RT distributions. The linear transformation model represents a rich family of models that includes the Cox proportional hazards model, the Box-Cox normal model, and many other models as special cases. This new model is embedded in a hierarchical framework so that both RTs and responses are modelled simultaneously. A two-stage estimation method is proposed. In the first stage, the Markov chain Monte Carlo method is employed to estimate the parametric part of the model. In the second stage, an estimating equation method with a recursive algorithm is adopted to estimate the non-parametric transformation. Applicability of the new model is demonstrated with a simulation study and a real data application. Finally, methods to evaluate the model fit are suggested. © 2012 The British Psychological Society.

  15. Time-Motion and Biological Responses in Simulated Mixed Martial Arts Sparring Matches.

    Science.gov (United States)

    Coswig, Victor S; Ramos, Solange de P; Del Vecchio, Fabrício B

    2016-08-01

    Coswig, VS, Ramos, SdP, and Del Vecchio, FB. Time-motion and biological responses in simulated mixed martial arts sparring matches. J Strength Cond Res 30(8): 2156-2163, 2016-Simulated matches are a relevant component of training for mixed martial arts (MMA) athletes. This study aimed to characterize time-motion responses and investigate physiological stress and neuromuscular changes related to MMA sparring matches. Thirteen athletes with an average age of 25 ± 5 years, body mass of 81.3 ± 9.5 kg, height of 176.2 ± 5.5 cm, and time of practice in MMA of 39 ± 25 months participated in the study. The fighters executed three 5-minute rounds with 1-minute intervals. Blood and salivary samples were collected and physical tests and psychometric questionnaires administered at 3 time points: before (PRE), immediately after (POST), and 48 hours after the combat (48 h). Statistical analysis applied analysis of variance for repeated measurements. In biochemical analysis, significant changes (p ≤ 0.05) were identified between PRE and POST (glucose: 80.3 ± 12.7 to 156.5 ± 19.1 mg·ml; lactate: 4 ± 1.7 to 15.6 ± 4.8 mmol·dl), POST and 48 hours (glucose: 156.5 ± 19.1 to 87.6 ± 15.5 mg·ml; lactate: 15.6 ± 4.8 to 2.9 ± 3.5 mmol·dl; urea: 44.1 ± 8.9 to 36.3 ± 7.8 mg·ml), and PRE and 48 hours (creatine kinase [CK]: 255.8 ± 137.4 to 395.9 ± 188.7 U/L). In addition, time-motion analyses showed a total high:low intensity of 1:2 and an effort:pause ratio of 1:3. In conclusion, simulated MMA sparring matches feature moderate to high intensity and a low degree of musculoskeletal damage, which can be seen by absence of physical performance and decrease in CK. Results of the study indicate that sparring training could be introduced into competitive microcycles to improve technical and tactical aspects of MMA matches, due to the high motor specificity and low muscle damage.

  16. A cross-language study of compensation in response to real-time formant perturbation

    DEFF Research Database (Denmark)

    Mitsuya, Takashi; MacDonald, Ewen; Purcell, David W.

    2011-01-01

    error operates at a purely acoustic level. This hypothesis was tested by comparing the response of three language groups to real-time formant perturbations, (1) native English speakers producing an English vowel /e/, (2) native Japanese speakers producing a Japanese vowel (=e...Past studies have shown that when formants are perturbed in real time, speakers spontaneously compensate for the perturbation by changing their formant frequencies in the opposite direction to the perturbation. Further, the pattern of these results suggests that the processing of auditory feedback...... for formant perturbation operates at a purely acoustic level was rejected. Rather, some level of phonological processing influences the feedback processing behavior....

  17. Aspek Internal dan Eksternal Kualitas Produksi Depot Air Minum Isi Ulang: Studi Kualitatif di Kota Bandung

    Directory of Open Access Journals (Sweden)

    Ardini Saptaningsih Raksanagara

    2018-03-01

    Internal and External Aspects Related to Quality of Refill Water Station Production: Qualitative Study in Bandung City The quality of water production in drinking water refill station (DWRS has recently been decreasing. Maintaining the quality of DWRS is not only the responsibility of the owners because the government should also playe an active role as the external supervisor. However, few information is available on the obstacles in monitoring the quality of DWRS. This study aimed to explore the internal and external aspects related to quality of drinking water production in DWRS. It was a qualitative study using phenomenology approach with constructivism paradigm. Data were collected through observation, indepth interviews, and document study. Data were analyzed using theme analysis. The place of study was Bandung City Health Office, Trade Service Unit, Primary Health Centers, and some DWRSs with inadequate water quality during May-August 2017. The result showed that internal aspects that related to drinking water quality were human resources, proper processing, appropiate equipments, and hygienic environment.  Inadequate human resource can cause unstandardized process production. External aspects included government supervision, sanctions, and law enforcement as well as collaboration between owner and local government. In conducting DWRS supervisory activities, the government has obstacles such as lack of human resources, lack of funding allocation, and multiple workloads. In addition, the absence of strict sanctions and the lack of cross-sectoral cooperation also contribute to the quality of refill drinking water, making it inadequate. New innovation should be developed to increase the quality of DWRS, particularly development of integrated supervison system which iincludes not only the local government but also the commmunity and consumers. Key words: Drinking water refill station, external aspect, internal aspect

  18. Determination of the Timing and Level of Activities of Lumbopelvic Muscles in Response to Postural Perturbations

    Directory of Open Access Journals (Sweden)

    S Ebrahimi Takamjani

    2005-05-01

    Full Text Available Background: One of the most important concerns in orthopedic medicine is the low back. Considering the importance of muscle function in preventing LBT by controlling too much load and stress applied on the spinal joints and ligaments. Materials and Methods: The aim of this research was to determine the timing and level of activities of lumbopelvic muscles in response to postural perturbations caused by unexpected loading of the upper limbs in standing on three different supporting surfaces (neutral, positive slope, negative slope in 20 healthy females 18 to 30 years old ( = 23.20 SD = 2.55 . The electromyographic signals were recorded from the deltoid, gluteus maximus, internal oblique abdominis and lumbar paraspinal muscles of the dominant side of the body to evaluate the onset time, end time, level of muscle activity (RMS and duration of different muscles in one task and one muscle in different tasks. Results: The results showed that the agonists (posterior muscles activated at first to compensate the flexor torque caused by loading and then the antagonists (anterior muscles switched-on to compensate the reaction forces caused by agonist activities. With regards to continuous activity of internal oblique and its attachments via thoracalumbar fascia to the transverse processes of the lumbar vertebrae, it can be considered as one of the major stabilizer muscles of the trunk . Conclusion: Finally the results indicated that supporting surface type didn’t have any effect on timing and scaling of muscle activities in different tasks suggesting that probably spinal and trunk priprioceptors are just responsible for triggering postural responses and they don’t have any role in determining timing and scaling.

  19. Accelerometer-measured dose-response for physical activity, sedentary time, and mortality in US adults

    DEFF Research Database (Denmark)

    Matthews, Charles E; Keadle, S. K.; Troiano, Richard P

    2016-01-01

    Background: Moderate-to-vigorous-intensity physical activity is recommended to maintain and improve health, but the mortality benefits of light activity and risk for sedentary time remain uncertain. Objectives: Using accelerometer-based measures, we 1) described the mortality dose-response...... for sedentary time and light-and moderateto-vigorous-intensity activity using restricted cubic splines, and 2) estimated the mortality benefits associated with replacing sedentary time with physical activity, accounting for total activity. Design: US adults (n = 4840) from NHANES (2003-2006) wore...... an accelerometer for #7 d and were followed prospectively for mortality. Proportional hazards models were used to estimate adjusted HRs and 95% CIs for mortality associations with time spent sedentary and in light-and moderate-to-vigorous-intensity physical activity. Splines were used to graphically present...

  20. Predictive event modelling in multicenter clinical trials with waiting time to response.

    Science.gov (United States)

    Anisimov, Vladimir V

    2011-01-01

    A new analytic statistical technique for predictive event modeling in ongoing multicenter clinical trials with waiting time to response is developed. It allows for the predictive mean and predictive bounds for the number of events to be constructed over time, accounting for the newly recruited patients and patients already at risk in the trial, and for different recruitment scenarios. For modeling patient recruitment, an advanced Poisson-gamma model is used, which accounts for the variation in recruitment over time, the variation in recruitment rates between different centers and the opening or closing of some centers in the future. A few models for event appearance allowing for 'recurrence', 'death' and 'lost-to-follow-up' events and using finite Markov chains in continuous time are considered. To predict the number of future events over time for an ongoing trial at some interim time, the parameters of the recruitment and event models are estimated using current data and then the predictive recruitment rates in each center are adjusted using individual data and Bayesian re-estimation. For a typical scenario (continue to recruit during some time interval, then stop recruitment and wait until a particular number of events happens), the closed-form expressions for the predictive mean and predictive bounds of the number of events at any future time point are derived under the assumptions of Markovian behavior of the event progression. The technique is efficiently applied to modeling different scenarios for some ongoing oncology trials. Case studies are considered. Copyright © 2011 John Wiley & Sons, Ltd.