WorldWideScience

Sample records for reference-less detection astrometry

  1. REFERENCE-LESS DETECTION, ASTROMETRY, AND PHOTOMETRY OF FAINT COMPANIONS WITH ADAPTIVE OPTICS

    International Nuclear Information System (INIS)

    Gladysz, Szymon; Christou, Julian C.

    2009-01-01

    We propose a complete framework for the detection, astrometry, and photometry of faint companions from a sequence of adaptive optics (AO) corrected short exposures. The algorithms exploit the difference in statistics between the on-axis and off-axis intensity of the AO point-spread function (PSF) to differentiate real sources from speckles. We validate the new approach and illustrate its performance using moderate Strehl ratio data obtained with the natural guide star AO system on the Lick Observatory's 3 m Shane Telescope. We obtain almost a 2 mag gain in achievable contrast by using our detection method compared to 5σ detectability in long exposures. We also present a first guide to expected accuracy of differential photometry and astrometry with the new techniques. Our approach performs better than PSF-fitting in general and especially so for close companions, which are located within the uncompensated seeing (speckle) halo. All three proposed algorithms are self-calibrating, i.e., they do not require observation of a calibration star. One of the advantages of this approach is improved observing efficiency.

  2. Astrometry VLBI in Space (AVS)

    Science.gov (United States)

    Cheng, Li-Jen; Reyes, George

    1995-01-01

    This paper describes a proposal for a new space radio astronomy mission for astrometry using Very Long Baseline Interferometry (VLBI) called Astrometry VLBI in Space (AVS). The ultimate goals of AVS are improving the accuracy of radio astrometry measurements to the microarcsecond level in one epoch of measurements and improving the accuracy of the transformation between the inertial radio and optical coordinate reference frames. This study will also assess the impact of this mission on astrophysics astrometry and geophysics.

  3. Astrometry VLBI in Space (AVS

    Science.gov (United States)

    Altunin, V.; Alekseev, V.; Akim, E.; Eubanks, M.; Kingham, K.; Treuhaft, R.; Sukhanov, K.

    1995-01-01

    A proposed new space radio astronomy mission for astrometry is described. The Astrometry VLBI (very long baseline) in Space (AVS) nominal mission includes two identical spacecraft, each with a 4-m antenna sending data to a 70-m ground station. The goals of AVS are improving astrometry accuracy to the microarcsecond level and improving the accuracy of the transformation between the inertial radio and optical coordinate reference frames.

  4. Ground-based Opportunities for Astrometry

    Science.gov (United States)

    2013-01-01

    science that is possible. The starting points for many of these projects are the surveys, such as 2MASS , DENIS, and the SDSS recently made with...Cutri, R. M. (2006). Extending the JCRF into the infrared: 2MASS -UCAC astrometry. In JDJ6: The International Celestial Reference Ssytem: Maintenance

  5. Observing exoplanet populations with high-precision astrometry

    Science.gov (United States)

    Sahlmann, Johannes

    2012-06-01

    This thesis deals with the application of the astrometry technique, consisting in measuring the position of a star in the plane of the sky, for the discovery and characterisation of extra-solar planets. It is feasible only with a very high measurement precision, which motivates the use of space observatories, the development of new ground-based astronomical instrumentation and of innovative data analysis methods: The study of Sun-like stars with substellar companions using CORALIE radial velocities and HIPPARCOS astrometry leads to the determination of the frequency of close brown dwarf companions and to the discovery of a dividing line between massive planets and brown dwarf companions; An observation campaign employing optical imaging with a very large telescope demonstrates sufficient astrometric precision to detect planets around ultra-cool dwarf stars and the first results of the survey are presented; Finally, the design and initial astrometric performance of PRIMA, ! a new dual-feed near-infrared interferometric observing facility for relative astrometry is presented.

  6. Results of the astrometry and direct imaging testbed for exoplanet detection

    Science.gov (United States)

    Bendek, Eduardo A.; Belikov, Ruslan; Pluzhnik, Eugene; Guyon, Olivier; Milster, Thomas; Johnson, Lee; Finan, Emily; Knight, Justin; Rodack, Alexander

    2017-09-01

    Measuring masses of long-period planets around F, G, and K stars is necessary to characterize exoplanets and assess their habitability. Imaging stellar astrometry offers a unique opportunity to solve radial velocity system inclination ambiguity and determine exoplanet masses. The main limiting factor in sparse-field astrometry, besides photon noise, is the non-systematic dynamic distortions that arise from perturbations in the optical train. Even space optics suffer from dynamic distortions in the optical system at the sub-μas level. To overcome this limitation we propose a diffractive pupil that uses an array of dots on the primary mirror creating polychromatic diffraction spikes in the focal plane, which are used to calibrate the distortions in the optical system. By combining this technology with a high-performance coronagraph, measurements of planetary systems orbits and masses can be obtained faster and more accurately than by applying traditional techniques separately. In this paper, we present the results of the combined astrometry and and highcontrast imaging experiments performed at NASA Ames Research Center as part of a Technology Development for Exoplanet Missions program. We demonstrated 2.38x10-5 λ/D astrometric accuracy per axis and 1.72x10-7 raw contrast from 1.6 to 4.5 λ/D. In addition, using a simple average subtraction post-processing we demonstrated no contamination of the coronagraph field down to 4.79x10-9 raw contrast.

  7. The Future of Astrometry in Space

    Directory of Open Access Journals (Sweden)

    Antonella Vallenari

    2018-04-01

    Full Text Available This contribution focuses on the importance of astrometry and on its future developments. Over the centuries astrometry has greatly contributed to the advance of the knowledge of the Universe. Nowadays a major breakthrough is on the way due to astrometric sky surveys from space. ESA space missions Hipparcos first and then Gaia point out the outstanding contribution that space astrometry can provide to our knowledge in many fields of astrophysics, going from the Milky Way formation and evolution, to stellar astrophysics, extra-galactic astrophysics, and fundamental physics. We briefly outline the properties of Gaia first and second data release, and the accuracies expected end-of-mission. The next big advance in space astrometry would be either to improve the astrometric accuracy of one order of magnitude, or to move to a different wavelength domain. While both options have the potential to bring us in a new era of discovery, they have to face enormous issues. We summarize the future directions in space astrometry that are proposed or under investigation by the scientific community, their main challenges and the expected outcome.

  8. Astrometry with A-Track Using Gaia DR1 Catalogue

    Science.gov (United States)

    Kılıç, Yücel; Erece, Orhan; Kaplan, Murat

    2018-04-01

    In this work, we built all sky index files from Gaia DR1 catalogue for the high-precision astrometric field solution and the precise WCS coordinates of the moving objects. For this, we used build-astrometry-index program as a part of astrometry.net code suit. Additionally, we added astrometry.net's WCS solution tool to our previously developed software which is a fast and robust pipeline for detecting moving objects such as asteroids and comets in sequential FITS images, called A-Track. Moreover, MPC module was added to A-Track. This module is linked to an asteroid database to name the found objects and prepare the MPC file to report the results. After these innovations, we tested a new version of the A-Track code on photometrical data taken by the SI-1100 CCD with 1-meter telescope at TÜBİTAK National Observatory, Antalya. The pipeline can be used to analyse large data archives or daily sequential data. The code is hosted on GitHub under the GNU GPL v3 license.

  9. WFIRST: Astrometry with the Wide-Field Imager

    Science.gov (United States)

    Bellini, Andrea; WFIRST Astrometry Working Group

    2018-01-01

    The wide field of view and stable, sharp images delivered by WFIRST's Wide-Field Imager make it an excellent instrument for astrometry, one of five major discovery areas identified in the 2010 Decadal Survey. Compared to the Hubble Space Telescope, WFIRST's wider field of view with similar image quality will provide hundreds more astrometric targets per image as well as background galaxies and stars with precise positions in the Gaia catalog. In addition, WFIRST will operate in the infrared, a wavelength regime where the most precise astrometry has so far been achieved with adaptive optics images from large ground-based telescopes. WFIRST will provide at least a factor of three improvement in astrometry over the current state of the art in this wavelength range, while spanning a field of view thousands of times larger. WFIRST is thus poised to make major contributions to multiple science topics in which astrometry plays an important role, without major alterations to the planned mission or instrument. We summarize a few of the most compelling science cases where WFIRST astrometry could prove transformational.

  10. High Accuracy Ground-based near-Earth-asteroid Astrometry using Synthetic Tracking

    Science.gov (United States)

    Zhai, Chengxing; Shao, Michael; Saini, Navtej; Sandhu, Jagmit; Werne, Thomas; Choi, Philip; Ely, Todd A.; Jacobs, Chirstopher S.; Lazio, Joseph; Martin-Mur, Tomas J.; Owen, William M.; Preston, Robert; Turyshev, Slava; Michell, Adam; Nazli, Kutay; Cui, Isaac; Monchama, Rachel

    2018-01-01

    Accurate astrometry is crucial for determining the orbits of near-Earth-asteroids (NEAs). Further, the future of deep space high data rate communications is likely to be optical communications, such as the Deep Space Optical Communications package that is part of the baseline payload for the planned Psyche Discovery mission to the Psyche asteroid. We have recently upgraded our instrument on the Pomona College 1 m telescope, at JPL's Table Mountain Facility, for conducting synthetic tracking by taking many short exposure images. These images can be then combined in post-processing to track both asteroid and reference stars to yield accurate astrometry. Utilizing the precision of the current and future Gaia data releases, the JPL-Pomona College effort is now demonstrating precision astrometry on NEAs, which is likely to be of considerable value for cataloging NEAs. Further, treating NEAs as proxies of future spacecraft that carry optical communication lasers, our results serve as a measure of the astrometric accuracy that could be achieved for future plane-of-sky optical navigation.

  11. Microarcsecond relative astrometry from the ground with a diffractive pupil

    Energy Technology Data Exchange (ETDEWEB)

    Ammons, S M; Bendek, E; Guyon, O

    2011-09-08

    The practical use of astrometry to detect exoplanets via the reflex motion of the parent star depends critically on the elimination of systematic floors in imaging systems. In the diffractive pupil technique proposed for space-based detection of exo-earths, extended diffraction spikes generated by a dotted primary mirror are referenced against a wide-field grid of background stars to calibrate changing optical distortion and achieve microarcsecond astrometric precision on bright targets (Guyon et al. 2010). We describe applications of this concept to ground-based uncrowded astrometry using a diffractive, monopupil telescope and a wide-field camera to image as many as {approx}4000 background reference stars. Final relative astrometric precision is limited by differential tip/tilt jitter caused by high altitude layers of turbulence. A diffractive 3-meter telescope is capable of reaching {approx}35 {micro}as relative astrometric error per coordinate perpendicular to the zenith vector in three hours on a bright target star (I < 10) in fields of moderate stellar density ({approx}40 stars arcmin{sup -2} with I < 23). Smaller diffractive apertures (D < 1 m) can achieve 100-200 {micro}as performance with the same stellar density and exposure time and a large telescope (6.5-10 m) could achieve as low as 10 {micro}as, nearly an order of magnitude better than current space-based facilities. The diffractive pupil enables the use of larger fields of view through calibration of changing optical distortion as well as brighter target stars (V < 6) by preventing star saturation. Permitting the sky to naturally roll to average signals over many thousands of pixels can mitigate the effects of detector imperfections.

  12. Global astrometry with the space interferometry mission

    Science.gov (United States)

    Boden, A.; Unwin, S.; Shao, M.

    1997-01-01

    The prospects for global astrometric measurements with the space interferometry mission (SIM) are discussed. The SIM mission will perform four microarcsec astrometric measurements on objects as faint as 20 mag using the optical interferometry technique with a 10 m baseline. The SIM satellite will perform narrow angle astrometry and global astrometry by means of an astrometric grid. The sensitivities of the SIM global astrometric performance and the grid accuracy versus instrumental parameters and sky coverage schemes are reported on. The problems in finding suitable astrometric grid objects to support microarcsec astrometry, and related ground-based observation programs are discussed.

  13. Atmospheric scintillation at Dome C, Antarctica: implications for photometry and astrometry

    Science.gov (United States)

    Kenyon, S.; Lawrence, J.; Ashley, M. C. B.; Storey, J. W. V.; Tokovinin, A.; Fossat, E.

    2006-08-01

    Night-time turbulence profiles of the atmosphere above Dome C, Antarctica, were measured during 2004, using a MASS instrument. We compare this data with turbulence profiles above Cerro Tololo and Cerro Pachon, also measured with a MASS, and find, with the exception of the owest layer, that Dome C has significantly less turbulence. In addition, the integrated at turbulence 16 km above Dome C is always less than the median values at the two Chilean sites. Using average wind speed profiles, we assess the photometric noise produced by scintillation, and the atmospheric contribution to the error budget in narrow angle differential astrometry. In comparison with the two mid-latitude sites in Chile, Dome C offers a potential gain of about 3.6 in both photometric precision (for long integrations) and narrow-angle astrometry precision. Although the data from Dome C cover a fairly limited time frame, they lend strong support to expectations that Dome C will offer significant advantages for photometric and astrometric studies.

  14. Modernizing Pickles - A Tool for Planning and Scheduling HST Astrometry

    Science.gov (United States)

    Juarez, Aaron; McArthur, B.; Benedict, G. F.

    2007-12-01

    Pickles is a Macintosh program written in C that was developed as a tool for determining pointings and rolls of the Hubble Space Telescope (HST) to place targets and astrometric reference stars in the Fine Guidance Sensor (FGS) field of regard ("pickles"). The program was developed in the late 1980s and runs under the "Classic” System. Ongoing HST astrometry projects require that this code be ported to the Intel-Mac OSX, because the Classic System is now unsupported. Pickles is a vital part of HST astrometry research. It graphically aids the investigator to determine where, when, and how the HST/FGS combination can observe an object and associated astrometric reference stars. Presently, Pickles can extract and display star positions from Guide Star Catalogs, such as the ACRS, SAO, and AGK3 catalogs via CD-ROMs. Future improvements will provide access to these catalogs and others through the internet. As an example of the past utility of Pickles, we highlight the recent determination of parallaxes for ten galactic Cepheids to determine an improved solar-metallicity Period-Luminosity relation. Support for this work was provided by NASA through grants GO-10989, -11210, and -11211 from the Space Telescope Science Institute, which is operated by the Association of Universities for Research in Astronomy, Inc., under NASA contract NAS5-26555.

  15. Deriving the true mass of an unresolved Brown Dwarf companion to an M-Dwarf with AO aided astrometry*

    Directory of Open Access Journals (Sweden)

    Kürster M.

    2011-07-01

    Full Text Available From radial velocity (RV detections alone one does not get all orbital parameters needed to derive the true mass of a non-transiting, unresolved substellar companion to a star. Additional astrometric measurements are needed to calculate the inclination and the longitude of the ascending node. Until today only few true substellar companion masses have been determined by this method with the HST fine guidance sensor [1, 2]. We aim to derive the true mass of a brown dwarf candidate companion to an early M 2.5V dwarf with groundbased high-resolution astrometry aided by adaptive optics. We found this unique brown dwarf desert object, whose distance to the host star is only 0.42 AU, in our UVES precision RV survey of M dwarfs, inferring a minimum companion mass of 27 Jupiter masses [3]. Combining the data with HIPPARCOS astrometry, we found a probability of only 2.9% that the companion is stellar. We therefore observed the host star together with a reference star within a monitoring program with VLT/NACO to derive the true mass of the companion and establish its nature (brown dwarf vs. star. Simultaneous observations of a reference field in a globular cluster are performed to determine the stability of the adaptive optics (AO plus detector system and check its suitability for such high-precision astrometric measurements over several epochs which are needed to find and analyse extrasolar planet systems.

  16. High-precision astrometry towards ELTs

    NARCIS (Netherlands)

    Massari, Davide; Fiorentino, Giuliana; Tolstoy, Eline; McConnachie, Alan; Stuik, Remko; Schreiber, Laura; Andersen, David; Clénet, Yann; Davies, Richard; Gratadour, Damien; Kuijken, Konrad; Navarro, Ramon; Pott, Jörg-Uwe; Rodeghiero, Gabriele; Turri, Paolo; Verdoes Kleijn, Gijs

    2016-01-01

    With the aim of paving the road for future accurate astrometry with MICADO at the European-ELT, we performed an astrometric study using two different but complementary approaches to investigate two critical components that contribute to the total astrometric accuracy. First, we tested the predicted

  17. Precision Photometry and Astrometry from Pan-STARRS

    Science.gov (United States)

    Magnier, Eugene A.; Pan-STARRS Team

    2018-01-01

    The Pan-STARRS 3pi Survey has been calibrated with excellent precision for both astrometry and photometry. The Pan-STARRS Data Release 1, opened to the public on 2016 Dec 16, provides photometry in 5 well-calibrated, well-defined bandpasses (grizy) astrometrically registered to the Gaia frame. Comparisons with other surveys illustrate the high quality of the calibration and provide tests of remaining systematic errors in both Pan-STARRS and those external surveys. With photometry and astrometry of roughly 3 billion astronomical objects, the Pan-STARRS DR1 has substantial overlap with Gaia, SDSS, 2MASS and other surveys. I will discuss the astrometric tie between Pan-STARRS DR1 and Gaia and show comparisons between Pan-STARRS and other large-scale surveys.

  18. International VLBI Service for Geodesy and Astrometry: 1999 Annual Report

    Science.gov (United States)

    Vandenberg, Nancy R. (Editor)

    1999-01-01

    This volume of reports is the 1999 Annual Report of the International VLBI Service for Geodesy and Astrometry -IVS. The individual reports were contributed by VLBI groups in the international geodetic community who constitute the components of IVS. The 1999 Annual Report documents the work of the IVS components for the year ending March 1, 1999, the official inauguration date of IVS. As the newest of the space technique services, IVS decided to publish this Annual Report as a reference to our organization and its components. The entire contents of this Annual Report also appear on the IVS website at: http://ivscc.gsfc.nasa.gov/pub/arl999. The IVS 1999 Annual Report will be a valuable reference for information about IVS and its components. This Annual Report will serve as a baseline from which we can measure the anticipated progress of IVS in coming years.

  19. THE BENEFITS OF VLBI ASTROMETRY TO PULSAR TIMING ARRAY SEARCHES FOR GRAVITATIONAL RADIATION

    Energy Technology Data Exchange (ETDEWEB)

    Madison, D. R.; Chatterjee, S.; Cordes, J. M. [Department of Astronomy and Center for Radiophysics and Space Research, Cornell University, Ithaca, NY 14850 (United States)

    2013-11-10

    Precision astrometry is an integral component of successful pulsar timing campaigns. Astrometric parameters are commonly derived by fitting them as parameters of a timing model to a series of pulse times of arrival (TOAs). TOAs measured to microsecond precision over spans of several years can yield position measurements with sub-milliarcsecond precision. However, timing-based astrometry can become biased if a pulsar displays any red spin noise or a red signal produced by the stochastic gravitational wave background. We investigate how noise of different spectral types is absorbed by timing models, leading to significant estimation biases in the astrometric parameters. We find that commonly used techniques for fitting timing models in the presence of red noise (Cholesky whitening) prevent the absorption of noise into the timing model remarkably well if the time baseline of observations exceeds several years, but are inadequate for dealing with shorter pulsar data sets. Independent of timing, pulsar-optimized very long baseline interferometry (VLBI) is capable of providing position estimates precise to the sub-milliarcsecond levels needed for high-precision timing. In order to make VLBI astrometric parameters useful in pulsar timing models, the transformation between the International Celestial Reference Frame (ICRF) and the dynamical solar system ephemeris used for pulsar timing must be constrained to within a few microarcseconds. We compute a transformation between the ICRF and pulsar timing frames and quantitatively discuss how the transformation will improve in coming years. We find that incorporating VLBI astrometry into the timing models of pulsars for which only a couple of years of timing data exist will lead to more realistic assessments of red spin noise and could enhance the amplitude of gravitational wave signatures in post-fit timing residuals by factors of 20 or more.

  20. Absolute Astrometry in the next 50 Years - II

    Science.gov (United States)

    Høg, E.

    2018-01-01

    With the Gaia astrometric satellite in orbit since December 2013 it is time to look at the future of fundamental astrometry and a time frame of 50 years is needed in this matter. A space mission with Gaia-like astrometric performance is required, but not necessarily a Gaia-like satellite. A dozen science issues for a Gaia successor mission in twenty years, with launch about 2035, are presented and in this context also other possibilities for absolute astrometry with milliarcsecond (mas) or sub-mas accuracies are discussed in my report at http://arxiv.org/abs/1408.2190. In brief, the two missions (2013 and 2035) would provide an astrometric foundation for all branches of astronomy from the solar system and stellar systems, including exo-planet systems with long periods, to compact galaxies, quasars and Dark Matter substructures by data which cannot be surpassed in the next 50 years.

  1. International VLBI Service for Geodesy and Astrometry: 2000 General Meeting Proceedings

    Science.gov (United States)

    Vandenberg, Nancy R. (Editor); Baver, Karen D. (Editor)

    2000-01-01

    This volume is the proceedings of the first General Meeting of the International Very Long Base Interferometry (VLBI) Service for Geodesy and Astrometry (IVS), held in Koetzting, Germany, February 21-24, 2000. The content of this volume also appears on the IVS web site at: http://ivscc.gsfc.nasa.gov/publications/gm2000. The goal of the program committee for the General Meeting was to provide an interesting and informative program for a wide cross section of IVS members, including station operators, program managers, and analysts. The program included reports, tutorials, invited and contributed papers, and poster presentations. The tutorial papers should be particularly useful references because each one provides an overview and introduction to a topic relevant to VLBI.

  2. Asteroid families, dynamics and astrometry

    International Nuclear Information System (INIS)

    Williams, J.G.; Gibson, J.

    1987-01-01

    The proper elements and family assignments for the 1227 Palomar-Leiden Survey asteroids of high quality were tabulated. In addition to the large table, there are also auxiliary tables of Mars crossers and commensurate objects, histograms of the proper element distributions, and a discussion. Probably the most important part of the discussion describes the Mars crossing boundary, how the closest distances of approach to Mars and Jupiter are calculated, and why the observed population of Mars crossers should bombard that planet episodically rather than uniformly. Analytical work was done to derive velocity distributions of family forming events from proper element distributions subject to assumptions which may be appropriate for cratering events. Software was developed for a microcomputer to permit plotting of the proper elements. Three orthogonal views are generated and stereo pairs can be printed when desired. This program was created for the study of asteroid families. The astrometry task is directed toward measuring and reducing positions on faint comets and the minor planets with less common orbits. The observational material is CCD frames taken with the Palomar 1.5 m telescope. Positions of 10 comets and 16 different asteroids were published on the Minor Planet Circulars

  3. Using Astrometrica to Teach an Introduction to Asteroid and Comet Astrometry

    Science.gov (United States)

    Durig, Douglas T.

    2007-05-01

    We have organized a Consortium for Astronomy Research and Teaching (CART) with several small colleges and universities from the Appalachian Colleges Association (ACA). In 2006 we received a small grant from the ACA Teaching and Learning Conference to develop laboratory exercises using the on-line telescopes of the Cordell-Lorenz Observatory of The University of the South in Sewanee, TN. We have completed and tested the first two, Asteroid Astrometry and Comet Astronomy and Angular Size. We are continuing to develop several more on the HR Diagram, Cataclysmic Variables and Short Period Variable Stars. We had unknown new asteroids in the field of view the first four times we performed the Asteroid Astrometry exercise but, unfortunately, none of the students recognized the new objects. However, they were more motivated to perform the exercise because of the opportunity to discover the new objects and they performed better on the review questions than students doing a comparable virtual exercise. Both of the astrometry exercises use the Astrometrica program developed by Herbert Raab and provide an introduction to the use and applications of this very functional shareware program. The program is available for free to educators.

  4. The Large Quasar Reference Frame (LQRF). An Optical Representation of the ICRS

    Science.gov (United States)

    2009-10-01

    faint regimes, both the 2MASS and the preliminary northernmost UCAC2 positions are shown of astrometry consistent with the UCAC2 main catalog, and the...is used. 2.7. 2MASS The Two Micron All-Sky Survey point source catalog (Cutri et al. 2003), hereafter 2MASS , derives from an uniform scan of the...17.1, H = 16.4, and K = 15.3. The 2MASS contains the position of 470 992 970 sources, but no proper motions. The astrometry is referred to the

  5. THE ARECIBO METHANOL MASER GALACTIC PLANE SURVEY. IV. ACCURATE ASTROMETRY AND SOURCE MORPHOLOGIES

    International Nuclear Information System (INIS)

    Pandian, J. D.; Momjian, E.; Xu, Y.; Menten, K. M.; Goldsmith, P. F.

    2011-01-01

    We present accurate absolute astrometry of 6.7 GHz methanol masers detected in the Arecibo Methanol Maser Galactic Plane Survey using MERLIN and the Expanded Very Large Array (EVLA). We estimate the absolute astrometry to be accurate to better than 15 and 80 mas for the MERLIN and EVLA observations, respectively. We also derive the morphologies of the maser emission distributions for sources stronger than ∼1 Jy. The median spatial extent along the major axis of the regions showing maser emission is ∼775 AU. We find a majority of methanol maser morphologies to be complex with some sources previously determined to have regular morphologies in fact being embedded within larger structures. This suggests that some maser spots do not have a compact core, which leads to them being resolved in high angular resolution observations. This also casts doubt on interpretations of the origin of methanol maser emission solely based on source morphologies. We also investigate the association of methanol masers with mid-infrared emission and find very close correspondence between methanol masers and 24 μm point sources. This adds further credence to theoretical models that predict methanol masers to be pumped by warm dust emission and firmly reinforces the finding that Class II methanol masers are unambiguous tracers of embedded high-mass protostars.

  6. The International Celestial Reference Frame (ICRF) and the Relationship Between Frames

    Science.gov (United States)

    Ma, Chopo

    2000-01-01

    The International Celestial Reference Frame (ICRF), a catalog of VLBI source positions, is now the basis for astrometry and geodesy. Its construction and extension/maintenance will be discussed as well as the relationship of the ICRF, ITRF, and EOP/nutation.

  7. Modeling Multi-wavelength Stellar Astrometry. III. Determination of the Absolute Masses of Exoplanets and Their Host Stars

    Science.gov (United States)

    Coughlin, J. L.; López-Morales, Mercedes

    2012-05-01

    Astrometric measurements of stellar systems are becoming significantly more precise and common, with many ground- and space-based instruments and missions approaching 1 μas precision. We examine the multi-wavelength astrometric orbits of exoplanetary systems via both analytical formulae and numerical modeling. Exoplanets have a combination of reflected and thermally emitted light that causes the photocenter of the system to shift increasingly farther away from the host star with increasing wavelength. We find that, if observed at long enough wavelengths, the planet can dominate the astrometric motion of the system, and thus it is possible to directly measure the orbits of both the planet and star, and thus directly determine the physical masses of the star and planet, using multi-wavelength astrometry. In general, this technique works best for, though is certainly not limited to, systems that have large, high-mass stars and large, low-mass planets, which is a unique parameter space not covered by other exoplanet characterization techniques. Exoplanets that happen to transit their host star present unique cases where the physical radii of the planet and star can be directly determined via astrometry alone. Planetary albedos and day-night contrast ratios may also be probed via this technique due to the unique signature they impart on the observed astrometric orbits. We develop a tool to examine the prospects for near-term detection of this effect, and give examples of some exoplanets that appear to be good targets for detection in the K to N infrared observing bands, if the required precision can be achieved.

  8. MODELING MULTI-WAVELENGTH STELLAR ASTROMETRY. III. DETERMINATION OF THE ABSOLUTE MASSES OF EXOPLANETS AND THEIR HOST STARS

    International Nuclear Information System (INIS)

    Coughlin, J. L.; López-Morales, Mercedes

    2012-01-01

    Astrometric measurements of stellar systems are becoming significantly more precise and common, with many ground- and space-based instruments and missions approaching 1 μas precision. We examine the multi-wavelength astrometric orbits of exoplanetary systems via both analytical formulae and numerical modeling. Exoplanets have a combination of reflected and thermally emitted light that causes the photocenter of the system to shift increasingly farther away from the host star with increasing wavelength. We find that, if observed at long enough wavelengths, the planet can dominate the astrometric motion of the system, and thus it is possible to directly measure the orbits of both the planet and star, and thus directly determine the physical masses of the star and planet, using multi-wavelength astrometry. In general, this technique works best for, though is certainly not limited to, systems that have large, high-mass stars and large, low-mass planets, which is a unique parameter space not covered by other exoplanet characterization techniques. Exoplanets that happen to transit their host star present unique cases where the physical radii of the planet and star can be directly determined via astrometry alone. Planetary albedos and day-night contrast ratios may also be probed via this technique due to the unique signature they impart on the observed astrometric orbits. We develop a tool to examine the prospects for near-term detection of this effect, and give examples of some exoplanets that appear to be good targets for detection in the K to N infrared observing bands, if the required precision can be achieved.

  9. International VLBI Service for Geodesy and Astrometry

    Science.gov (United States)

    Vandenberg, Nancy R. (Editor); Baver, Karen D. (Editor)

    2001-01-01

    This volume of reports is the 2000 Annual Report of the International Very Long Base Interferometry (VLBI) Service for Geodesy and Astrometry (IVS). The individual reports were contributed by VLBI groups in the international geodetic and astrometric community who constitute the components of IVS. The 2000 Annual Report documents the work of these IVS components over the period March 1, 1999, through December 31, 2000. The reports document changes, activities, and progress of the IVS. The entire contents of this Annual Report also appear on the IVS web site at http://ivscc.gsfc.nasa.gov/publications/ar2000.

  10. An Improved Technique for the Photometry and Astrometry of Faint Companions

    Science.gov (United States)

    Burke, Daniel; Gladysz, Szymon; Roberts, Lewis; Devaney, Nicholas; Dainty, Chris

    2009-07-01

    We propose a new approach to differential astrometry and photometry of faint companions in adaptive optics images. It is based on a prewhitening matched filter, also referred to in the literature as the Hotelling observer. We focus on cases where the signal of the companion is located within the bright halo of the parent star. Using real adaptive optics data from the 3 m Shane telescope at the Lick Observatory, we compare the performance of the Hotelling algorithm with other estimation algorithms currently used for the same problem. The real single-star data are used to generate artificial binary objects with a range of magnitude ratios. In most cases, the Hotelling observer gives significantly lower astrometric and photometric errors. In the case of high Strehl ratio (SR) data (SR ≈ 0.5), the differential photometry of a binary star with a Δm = 4.5 and a separation of 0.6″ is better than 0.1 mag a factor of 2 lower than the other algorithms considered.

  11. Vienna VLBI and Satellite Software (VieVS) for Geodesy and Astrometry

    Science.gov (United States)

    Böhm, Johannes; Böhm, Sigrid; Boisits, Janina; Girdiuk, Anastasiia; Gruber, Jakob; Hellerschmied, Andreas; Krásná, Hana; Landskron, Daniel; Madzak, Matthias; Mayer, David; McCallum, Jamie; McCallum, Lucia; Schartner, Matthias; Teke, Kamil

    2018-04-01

    The Vienna VLBI and Satellite Software (VieVS) is state-of-the-art Very Long Baseline Interferometry (VLBI) analysis software for geodesy and astrometry. VieVS has been developed at Technische Universität Wien (TU Wien) since 2008, where it is used for research purposes and for teaching space geodetic techniques. In the past decade, it has been successfully applied on Very Long Baseline Interferometry (VLBI) observations for the determination of celestial and terrestrial reference frames as well as for the estimation of celestial pole offsets, universal Time (UT1-UTC), and polar motion based on least-squares adjustment. Furthermore, VieVS is equipped with tools for scheduling and simulating VLBI observations to extragalactic radio sources as well as to satellites and spacecraft, features which proved to be very useful for a variety of applications. VieVS is now available as version 3.0 and we do provide the software to all interested persons and institutions. A wiki with more information about VieVS is available at http://vievswiki.geo.tuwien.ac.at/.

  12. International VLBI Service for Geodesy and Astrometry: General Meeting Proceedings

    Science.gov (United States)

    Vandenberg, Nancy R. (Editor); Baver, Karen D. (Editor)

    2002-01-01

    This volume contains the proceedings of the second General Meeting of the International VLBI Service for Geodesy and Astrometry (IVS), held in Tsukuba, Japan, February 4-7, 2002. The contents of this volume also appear on the IVS Web site at http://ivscc.gsfc.nasa.gov/publications/gm2002. The key-note of the second GM was prospectives for the future, in keeping with the re-organization of the IAG around the motivation of geodesy as 'an old science with a dynamic future' and noting that providing reference frames for Earth system science that are consistent over decades on the highest accuracy level will provide a challenging role for IVS. The goal of the meeting was to provide an interesting and informative program for a wide cross section of IVS members, including station operators, program managers, and analysts. This volume contains 72 papers and five abstracts of papers presented at the GM. The volume also includes reports about three splinter meetings held in conjunction with the GM: a mini-TOW (Technical Operations Workshop), the third IVS Analysis Workshop and a meeting of the analysis working group on geophysical modeling.

  13. Combined astrometric catalogue EOC-3 An improved reference frame for long-term Earth rotation studies

    Czech Academy of Sciences Publication Activity Database

    Vondrák, Jan; Štefka, Vojtěch

    2007-01-01

    Roč. 463, č. 2 (2007), s. 783-788 ISSN 0004-6361 R&D Projects: GA MŠk(CZ) LC506 Institutional research plan: CEZ:AV0Z10030501 Keywords : reference systems * astrometry * catalogs Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 4.259, year: 2007

  14. Astrometry of 2014MU69 for New Horizons encounter

    Science.gov (United States)

    Buie, Marc

    2017-08-01

    We propose 12 orbits of time to make high-precision astrometric measurments of the New Horizons extendedmission target, (486958) 2014MU69. These observations are in direct support of the navigation of New Horizonsleading up to its encounter in Jan 2019. These visits represent an optimized plan for improved orbit estimates that willcomplete as the target becomes directly observable by New Horizons. This astrometry is a key element leadingup to a close investigation of a Cold-Classical Kuiper Belt Object, one of the most primitive members of our solarsystem.

  15. Gaia Data Release 1 Open cluster astrometry: performance, limitations, and future prospects

    Czech Academy of Sciences Publication Activity Database

    van Leeuwen, F.; Vallenari, A.; Jordi, C.; Lindegren, L.; Bastian, U.; Prusti, T.; de Bruijne, J.H.J.; Brown, A.G.A.; Babusiaux, C.; Bailer-Jones, C.A.L.; Fuchs, Jan; Koubský, Pavel; Votruba, Viktor

    2017-01-01

    Roč. 601, May (2017), A19/1-A19/65 E-ISSN 1432-0746 R&D Projects: GA MŠk(CZ) LG15010 Grant - others:ESA(XE) ESA-PECS project No. 98058 Institutional support: RVO:67985815 Keywords : astrometry * open clusters and associations * proper motion and parallax Subject RIV: BN - Astronomy , Celestial Mechanics, Astrophysics OBOR OECD: Astronomy (including astrophysics,space science) Impact factor: 5.014, year: 2016

  16. International VLBI Service for Geodesy and Astrometry 2007 Annual Report

    Science.gov (United States)

    Behrend, D. (Editor); Baver, K. D. (Editor)

    2008-01-01

    This volume of reports is the 2007 Annual Report of the International VLBI Service for Geodesy and Astrometry (IVS). The individual reports were contributed by VLBI groups in the international geodetic and astrometric community who constitute the components of IVS. The 2007 Annual Report documents the work of these IVS components over the period January 1, 2007 through December 31, 2007. The reports document changes, activities, and progress of the IVS. The entire contents of this Annual Report also appear on the IVS Web site at http://ivscc.gsfc.nasa.gov/publications/ar2007.

  17. International VLBI Service for Geodesy and Astrometry 2008 Annual Report

    Science.gov (United States)

    Behrend, Dirk; Baver, Karen D.

    2009-01-01

    This volume of reports is the 2008 Annual Report of the International VLBI Service for Geodesy and Astrometry (IVS). The individual reports were contributed by VLBI groups in the international geodetic and astrometric community who constitute the components of IVS. The 2008 Annual Report documents the work of these IVS components over the period January 1, 2008 through December 31, 2008. The reports document changes, activities, and progress of the IVS. The entire contents of this Annual Report also appear on the IVS Web site at http://ivscc.gsfc.nasa.gov/publications/ar2008.

  18. International VLBI Service for Geodesy and Astrometry 2011 Annual Report

    Science.gov (United States)

    Baver, Karen D. (Editor); Behrend, Dirk

    2012-01-01

    This volume of reports is the 2011 Annual Report of the International VLBI Service for Geodesy and Astrometry (IVS). The individual reports were contributed by VLBI groups in the international geodetic and astrometric community who constitute the components of IVS. The 2011 Annual Report documents the work of these IVS components over the period January 1, 2011 through December 31, 2011. The reports document changes, activities, and progress of the IVS. The entire contents of this Annual Report also appear on the IVS Web site at http://ivscc.gsfc.nasa.gov/publications/ar2011.

  19. International VLBI Service for Geodesy and Astrometry 2005 Annual Report

    Science.gov (United States)

    Behrend, Dirk (Editor); Baver, Karen D. (Editor)

    2006-01-01

    This volume of reports is the 2005 Annual Report of the International VLBI Service for Geodesy and Astrometry (IVS). The individual reports were contributed by VLBI groups in the international geodetic and astrometric community who constitute the components of IVS. The 2005 Annual Report documents the work of these IVS components over the period January 1, 2005 through December 31, 2005. The reports document changes, activities, and progress of the IVS. The entire contents of this Annual Report also appear on the IVS Web site at http://ivscc.gsfc.nasa.gov/publications/ar2005.

  20. International VLBI Service for Geodesy and Astrometry 2000 Annual Report

    Science.gov (United States)

    Vandenberg, N. R. (Editor); Baver, K. D. (Editor); Smith, David E. (Technical Monitor)

    2000-01-01

    This volume of reports is the 2000 Annual Report of the International Very Long Base Interferometry (VLBI) Service for Geodesy and Astrometry (IVS). The individual reports were contributed by VLBI groups in the international geodetic and astrometric community who constitute the permanent components of IVS. The IVS 2000 Annual Report documents the work of the IVS components for the period March 1, 1999 (the official inauguration date of IVS) through December 31, 2000. The reports document changes, activities, and progress of the IVS. The entire contents of this Annual Report also appear on the IVS web site at http://ivscc.gsfc.nasa.gov/publications/ar2000. This book and the web site are organized as follows: (1) The first section contains general information about IVS, a map showing the location of the components, information about the Directing Board members, and the report of the IVS Chair; (2) The second section of Special Reports contains a status report of the IVS Working Group on GPS phase center mapping, a reproduction of the resolution making IVS a Service of the International Astronomical Union (IAU), and a reprint of the VLBI Standard Interface (VSI); (3) The next seven sections hold the component reports from the Coordinators, Network Stations, Operation Centers, Correlators, Data Centers, Analysis Centers, and Technology Development Centers; and (4) The last section includes reference information about IVS: the Terms of Reference, the lists of Member and Affiliated organizations, the IVS Associate Member list, a complete list of IVS components, the list of institutions contributing to this report, and a list of acronyms. The 2000 Annual Report demonstrates the vitality of the IVS and the outstanding progress we have made during our first 22 months.

  1. Object detection by correlation coefficients using azimuthally averaged reference projections.

    Science.gov (United States)

    Nicholson, William V

    2004-11-01

    A method of computing correlation coefficients for object detection that takes advantage of using azimuthally averaged reference projections is described and compared with two alternative methods-computing a cross-correlation function or a local correlation coefficient versus the azimuthally averaged reference projections. Two examples of an application from structural biology involving the detection of projection views of biological macromolecules in electron micrographs are discussed. It is found that a novel approach to computing a local correlation coefficient versus azimuthally averaged reference projections, using a rotational correlation coefficient, outperforms using a cross-correlation function and a local correlation coefficient in object detection from simulated images with a range of levels of simulated additive noise. The three approaches perform similarly in detecting macromolecular views in electron microscope images of a globular macrolecular complex (the ribosome). The rotational correlation coefficient outperforms the other methods in detection of keyhole limpet hemocyanin macromolecular views in electron micrographs.

  2. Gaia Data Release 1. Open cluster astrometry: performance, limitations, and future prospects

    OpenAIRE

    Gaia Collaboration; van Leeuwen, F.; Vallenari, A.; Jordi, C.; Lindegren, L.; Bastian, U.; Prusti, T.; de Bruijne, J. H. J.; Brown, A. G. A.; Babusiaux, C.; Bailer-Jones, C. A. L.; Biermann, M.; Evans, D. W.; Eyer, L.; Jansen, F.

    2017-01-01

    Context. Parallaxes for 331 classical Cepheids, 31 Type II Cepheids, and 364 RR Lyrae stars in common between Gaia and the Hipparcos and Tycho-2 catalogues are published in Gaia Data Release 1 (DR1) as part of the Tycho-Gaia Astrometric Solution (TGAS). \\ud Aims. In order to test these first parallax measurements of the primary standard candles of the cosmological distance ladder, which involve astrometry collected by Gaia during the initial 14 months of science operation, we compared them wi...

  3. An engineered design of a diffractive mask for high precision astrometry

    Science.gov (United States)

    Dennison, Kaitlin; Ammons, S. Mark; Garrel, Vincent; Marin, Eduardo; Sivo, Gaetano; Bendek, Eduardo; Guyon, Oliver

    2016-07-01

    AutoCAD, Zemax Optic Studio 15, and Interactive Data Language (IDL) with the Proper Library are used to computationally model and test a diffractive mask (DiM) suitable for use in the Gemini Multi-Conjugate Adaptive Optics System (GeMS) on the Gemini South Telescope. Systematic errors in telescope imagery are produced when the light travels through the adaptive optics system of the telescope. DiM is a transparent, flat optic with a pattern of miniscule dots lithographically applied to it. It is added ahead of the adaptive optics system in the telescope in order to produce diffraction spots that will encode systematic errors in the optics after it. Once these errors are encoded, they can be corrected for. DiM will allow for more accurate measurements in astrometry and thus improve exoplanet detection. The mechanics and physical attributes of the DiM are modeled in AutoCAD. Zemax models the ray propagation of point sources of light through the telescope. IDL and Proper simulate the wavefront and image results of the telescope. Aberrations are added to the Zemax and IDL models to test how the diffraction spots from the DiM change in the final images. Based on the Zemax and IDL results, the diffraction spots are able to encode the systematic aberrations.

  4. International VLBI Service for Geodesy and Astrometry 2013 Annual Report

    Science.gov (United States)

    Baver, Karen D.; Behrend, Dirk; Armstrong, Kyla L.

    2014-01-01

    This volume of reports is the 2013 Annual Report of the International VLBI Service for Geodesy and Astrometry (IVS). The individual reports were contributed by VLBI groups in the international geodetic and astrometric community who constitute the permanent components of IVS. The IVS 2013 Annual Report documents the work of the IVS components for the calendar year 2013, our fifteenth year of existence. The reports describe changes, activities, and progress of the IVS. Many thanks to all IVS components who contributed to this Annual Report. With the exception of the first section and the last section, the contents of this Annual Report also appear on the IVS Web site at http://ivscc.gsfc.nasa.gov/publications/ar2013.

  5. Computer-aided detection of colorectal polyps: can it improve sensitivity of less-experienced readers? Preliminary findings.

    Science.gov (United States)

    Baker, Mark E; Bogoni, Luca; Obuchowski, Nancy A; Dass, Chandra; Kendzierski, Renee M; Remer, Erick M; Einstein, David M; Cathier, Pascal; Jerebko, Anna; Lakare, Sarang; Blum, Andrew; Caroline, Dina F; Macari, Michael

    2007-10-01

    To determine whether computer-aided detection (CAD) applied to computed tomographic (CT) colonography can help improve sensitivity of polyp detection by less-experienced radiologist readers, with colonoscopy or consensus used as the reference standard. The release of the CT colonographic studies was approved by the individual institutional review boards of each institution. Institutions from the United States were HIPAA compliant. Written informed consent was waived at all institutions. The CT colonographic studies in 30 patients from six institutions were collected; 24 images depicted at least one confirmed polyp 6 mm or larger (39 total polyps) and six depicted no polyps. By using an investigational software package, seven less-experienced readers from two institutions evaluated the CT colonographic images and marked or scored polyps by using a five-point scale before and after CAD. The time needed to interpret the CT colonographic findings without CAD and then to re-evaluate them with CAD was recorded. For each reader, the McNemar test, adjusted for clustered data, was used to compare sensitivities for readers without and with CAD; a Wilcoxon signed-rank test was used to analyze the number of false-positive results per patient. The average sensitivity of the seven readers for polyp detection was significantly improved with CAD-from 0.810 to 0.908 (P=.0152). The number of false-positive results per patient without and with CAD increased from 0.70 to 0.96 (95% confidence interval for the increase: -0.39, 0.91). The mean total time for the readings was 17 minutes 54 seconds; for interpretation of CT colonographic findings alone, the mean time was 14 minutes 16 seconds; and for review of CAD findings, the mean time was 3 minutes 38 seconds. Results of this feasibility study suggest that CAD for CT colonography significantly improves per-polyp detection for less-experienced readers. Copyright (c) RSNA, 2007.

  6. CosmoQuest Transient Tracker: Opensource Photometry & Astrometry software

    Science.gov (United States)

    Myers, Joseph L.; Lehan, Cory; Gay, Pamela; Richardson, Matthew; CosmoQuest Team

    2018-01-01

    CosmoQuest is moving from online citizen science, to observational astronomy with the creation of Transient Trackers. This open source software is designed to identify asteroids and other transient/variable objects in image sets. Transient Tracker’s features in final form will include: astrometric and photometric solutions, identification of moving/transient objects, identification of variable objects, and lightcurve analysis. In this poster we present our initial, v0.1 release and seek community input.This software builds on the existing NIH funded ImageJ libraries. Creation of this suite of opensource image manipulation routines is lead by Wayne Rasband and is released primarily under the MIT license. In this release, we are building on these libraries to add source identification for point / point-like sources, and to do astrometry. Our materials released under the Apache 2.0 license on github (http://github.com/CosmoQuestTeam) and documentation can be found at http://cosmoquest.org/TransientTracker.

  7. Some new results on the central overlap problem in astrometry

    Science.gov (United States)

    Rapaport, M.

    1998-07-01

    The central overlap problem in astrometry has been revisited in the recent last years by Eichhorn (1988) who explicitly inverted the matrix of a constrained least squares problem. In this paper, the general explicit solution of the unconstrained central overlap problem is given. We also give the explicit solution for an other set of constraints; this result is a confirmation of a conjecture expressed by Eichhorn (1988). We also consider the use of iterative methods to solve the central overlap problem. A surprising result is obtained when the classical Gauss Seidel method is used; the iterations converge immediately to the general solution of the equations; we explain this property writing the central overlap problem in a new set of variables.

  8. BAM/DASS: Data Analysis Software for Sub-Microarcsecond Astrometry Device

    Science.gov (United States)

    Gardiol, D.; Bonino, D.; Lattanzi, M. G.; Riva, A.; Russo, F.

    2010-12-01

    The INAF - Osservatorio Astronomico di Torino is part of the Data Processing and Analysis Consortium (DPAC) for Gaia, a cornerstone mission of the European Space Agency. Gaia will perform global astrometry by means of two telescopes looking at the sky along two different lines of sight oriented at a fixed angle, also called basic angle. Knowledge of the basic angle fluctuations at the sub-microarcsecond level over periods of the order of the minute is crucial to reach the mission goals. A specific device, the Basic Angle Monitoring, will be dedicated to this purpose. We present here the software system we are developing to analyze the BAM data and recover the basic angle variations. This tool is integrated into the whole DPAC data analysis software.

  9. International VLBI Service for Geodesy and Astrometry 2012 Annual Report

    Science.gov (United States)

    Baver, Karen D.; Behrend, Dirk; Armstrong, Kyla L.

    2013-01-01

    This volume of reports is the 2012 Annual Report of the International VLBI Service for Geodesy and Astrometry (IVS). The individual reports were contributed by VLBI groups in the international geodetic and astrometric community who constitute the permanent components of IVS. The IVS 2012 Annual Report documents the work of the IVS components for the calendar year 2012, our fourteenth year of existence. The reports describe changes, activities, and progress ofthe IVS. Many thanks to all IVS components who contributed to this Annual Report. With the exception of the first section and parts of the last section (described below), the contents of this Annual Report also appear on the IVS Web site athttp:ivscc.gsfc.nasa.gov/publications/ar2012

  10. Recent Radar Astrometry of Asteroid 2004 MN4

    Science.gov (United States)

    Giorgini, J. D.; Benner, L. A. M.; Nolan, M. C.; Ostro, S. J.

    2005-05-01

    Arecibo (2380-MHz) delay-Doppler radar astrometry obtained in late January of 2005 significantly corrected 2004 MN4's orbit. Doppler-shifted echoes were acquired 4.8-sigma away from the predicted frequency on Jan 27, while range to the object on Jan 29 was found to be 747 km (2.8-sigma) closer to Earth than the pre-radar orbit solution predicted. Incorporation of these radar measurements into least-squares orbit solution #82 resulted in a new predicted Earth encounter on 2029-Apr-13 of 36000 +/- 9900 km (3-sigma formal uncertainties), or 5.6 +/- 1.6 Earth radii, from Earth's center. This is inside geosynchronous orbit and 27700 km (4.3 Earth radii) closer to Earth than predicted by the pre-radar ephemeris -- a 5-sigma change compared to the pre-radar orbit solution, illustrating the problematic nature of prediction and statistical analysis when only single-apparition optical data-sets are available. The current data-set does not permit reliable trajectory propagation to encounters later than 2029; this may not be possible until data from 2012-2013 are available. The corrected nominal approach distance in 2029 is approximately twice the classical Roche limit and closer than any known past or future approach by a natural object larger than 10 m, other than those detected after already impacting the Earth or it's atmosphere. Such close approaches by objects as large as 2004 MN4 (D ≳ 0.3 km) are currently thought to occur at ≳ 1000-year intervals on average. 2004 MN4 is expected to reach 3rd magnitude for observers in Europe, western Asia, and Africa, and thus be visible to the unaided eye. The asteroid's disk will be 2-4 arcseconds across and potentially resolvable with small ground-based telescopes.

  11. Radio emission from Supernovae and High Precision Astrometry

    Science.gov (United States)

    Perez-Torres, M. A.

    1999-11-01

    The present thesis work makes contributions in two scientific fronts: differential astrometry over the largest angular scales ever attempted (approx. 15 arcdegrees) and numerical simulations of radio emission from very young supernovae. In the first part, we describe the results of the use of very-long-baseline interferometry (VLBI) in one experiment designed to measure with very high precision the angular distance between the radio sources 1150+812 (QSO) and 1803+784 (BL Lac). We observed the radio sources on 19 November 1993 using an intercontinental array of radio telescopes, which simultaneously recorded at 2.3 and 8.4 GHz. VLBI differential astrometry is capable, Nature allowing, of yielding source positions with precisions well below the milliarcsecond level. To achieve this precision, we first had to accurately model the rotation of the interferometric fringes via the most precise models of Earth Orientation Parameters (EOP; precession, polar motion and UT1, nutation). With this model, we successfully connected our phase delay data at both frequencies and, using difference astrometric techniques, determined the coordinates of 1803+784 relative to those of 1150+812-within the IERS reference frame--with an standard error of about 0.6 mas in each coordinate. We then corrected for several effects including propagation medium (mainly the atmosphere and ionosphere), and opacity and source-structure effects within the radio sources. We stress that our dual-frequency measurements allowed us to accurately subtract the ionosphere contribution from our data. We also used GPS-based TEC measurements to independently find the ionosphere contribution, and showed that these contributions agree with our dual-frequency measurements within about 2 standard deviations in the less favorables cases (the longest baselines), but are usually well within one standard deviation. Our estimates of the relative positions, whether using dual-frequency-based or GPS-based ionosphere

  12. Microlensing and Its Degeneracy Breakers: Parallax, Finite Source, High-Resolution Imaging, and Astrometry

    Directory of Open Access Journals (Sweden)

    Chien-Hsiu Lee

    2017-07-01

    Full Text Available First proposed by Paczynski in 1986, microlensing has been instrumental in the search for compact dark matter as well as discovery and characterization of exoplanets. In this article, we provide a brief history of microlensing, especially on the discoveries of compact objects and exoplanets. We then review the basics of microlensing and how astrometry can help break the degeneracy, providing a more robust determination of the nature of the microlensing events. We also outline prospects that will be made by on-going and forth-coming experiments/observatories.

  13. WCSTools 3.0: More Tools for Image Astrometry and Catalog Searching

    Science.gov (United States)

    Mink, Douglas J.

    For five years, WCSTools has provided image astrometry for astronomers who need accurate positions for objects they wish to observe. Other functions have been added and improved since the package was first released. Support has been added for new catalogs, such as the GSC-ACT, 2MASS Point Source Catalog, and GSC II, as they have been published. A simple command line interface can search any supported catalog, returning information in several standard formats, whether the catalog is on a local disk or searchable over the World Wide Web. The catalog searching routine can be located on either end (or both ends!) of such a web connection, and the output from one catalog search can be used as the input to another search.

  14. The Dynamics of the Local Group in the Era of Precision Astrometry

    Science.gov (United States)

    Besla, Gurtina; Garavito-Camargo, Nicolas; Patel, Ekta

    2018-06-01

    Our understanding of the dynamics of our Local Group of galaxies has changed dramatically over the past few years owing to significant advancements in astrometry and our theoretical understanding of galaxy structure. New surveys now enable us to map the 3D structure of our Milky Way and the dynamics of tracers of its dark matter distribution, like globular clusters, satellite galaxies and streams, with unprecedented precision. Some results have met with controversy, challenging preconceived notions of the orbital dynamics of key components of the Local Group. I will provide an overview of this evolving picture of our Local Group and outline how we can test the cold dark matter paradigm in the era of Gaia, LSST and JWST.

  15. Introducing ADES: A New IAU Astrometry Data Exchange Standard

    Science.gov (United States)

    Chesley, Steven R.; Hockney, George M.; Holman, Matthew J.

    2017-10-01

    For several decades, small body astrometry has been exchanged, distributed and archived in the form of 80-column ASCII records. As a replacement for this obsolescent format, we have worked with a number of members of the community to develop the Astrometric Data Exchange Standard (ADES), which was formally adopted by IAU Commission 20 in August 2015 at the XXIX General Assembly in Honolulu, Hawaii.The purpose of ADES is to ensure that useful and available observational information is submitted, archived, and disseminated as needed. Availability of more complete information will allow orbit computers to process the data more correctly, leading to improved accuracy and reliability of orbital fits. In this way, it will be possible to fully exploit the improving accuracy and increasing number of both optical and radar observations. ADES overcomes several limitations of the previous format by allowing characterization of astrometric and photometric errors, adequate precision in time and angle fields, and flexibility and extensibility.To accommodate a diverse base of users, from automated surveys to hands-on follow-up observers, the ADES protocol allows for two file formats, eXtensible Markup Language (XML) and Pipe-Separated Values (PSV). Each format carries the same information and simple tools allow users to losslessly transform back and forth between XML and PSV.We have further developed and refined ADES since it was first announced in July 2015 [1]. The proposal at that time [2] has undergone several modest revisions to aid validation and avoid overloaded fields. We now have validation schema and file transformation utilities. Suitable example files, test suites, and input/output libraries in a number of modern programming languages are now available. Acknowledgements: Useful feedback during the development of ADES has been received from numerous colleagues in the community of observers and orbit specialists working on asteroids comets and planetary satellites

  16. The solar neighborhood. XXXIV. A search for planets orbiting nearby M dwarfs using astrometry

    International Nuclear Information System (INIS)

    Lurie, John C.; Henry, Todd J.; Ianna, Philip A.; Jao, Wei-Chun; Quinn, Samuel N.; Winters, Jennifer G.; Koerner, David W.; Riedel, Adric R.; Subasavage, John P.

    2014-01-01

    Astrometric measurements are presented for seven nearby stars with previously detected planets: six M dwarfs (GJ 317, GJ 667C, GJ 581, GJ 849, GJ 876, and GJ 1214) and one K dwarf (BD-10 -3166). Measurements are also presented for six additional nearby M dwarfs without known planets, but which are more favorable to astrometric detections of low mass companions, as well as three binary systems for which we provide astrometric orbit solutions. Observations have baselines of 3 to 13 years, and were made as part of the RECONS long-term astrometry and photometry program at the CTIO/SMARTS 0.9 m telescope. We provide trigonometric parallaxes and proper motions for all 16 systems, and perform an extensive analysis of the astrometric residuals to determine the minimum detectable companion mass for the 12 M dwarfs not having close stellar secondaries. For the six M dwarfs with known planets, we are not sensitive to planets, but can rule out the presence of all but the least massive brown dwarfs at periods of 2–12 years. For the six more astrometrically favorable M dwarfs, we conclude that none have brown dwarf companions, and are sensitive to companions with masses as low as 1 M Jup for periods longer than two years. In particular, we conclude that Proxima Centauri has no Jovian companions at orbital periods of 2–12 years. These results complement previously published M dwarf planet occurrence rates by providing astrometrically determined upper mass limits on potential super-Jupiter companions at orbits of two years and longer. As part of a continuing survey, these results are consistent with the paucity of super-Jupiter and brown dwarf companions we find among the over 250 red dwarfs within 25 pc observed longer than five years in our astrometric program.

  17. The solar neighborhood. XXXIV. A search for planets orbiting nearby M dwarfs using astrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lurie, John C. [Department of Astronomy, University of Washington, Seattle, WA 98195 (United States); Henry, Todd J.; Ianna, Philip A. [RECONS Institute, Chambersburg, PA 17201 (United States); Jao, Wei-Chun; Quinn, Samuel N.; Winters, Jennifer G. [Department of Physics and Astronomy, Georgia State University, Atlanta, GA 30302 (United States); Koerner, David W. [Department of Physics and Astronomy, Northern Arizona University, Flagstaff, AZ 86011 (United States); Riedel, Adric R. [Department of Astrophysics, American Museum of Natural History, New York, NY 10034 (United States); Subasavage, John P., E-mail: lurie@uw.edu [United States Naval Observatory, Flagstaff, AZ 86001 (United States)

    2014-11-01

    Astrometric measurements are presented for seven nearby stars with previously detected planets: six M dwarfs (GJ 317, GJ 667C, GJ 581, GJ 849, GJ 876, and GJ 1214) and one K dwarf (BD-10 -3166). Measurements are also presented for six additional nearby M dwarfs without known planets, but which are more favorable to astrometric detections of low mass companions, as well as three binary systems for which we provide astrometric orbit solutions. Observations have baselines of 3 to 13 years, and were made as part of the RECONS long-term astrometry and photometry program at the CTIO/SMARTS 0.9 m telescope. We provide trigonometric parallaxes and proper motions for all 16 systems, and perform an extensive analysis of the astrometric residuals to determine the minimum detectable companion mass for the 12 M dwarfs not having close stellar secondaries. For the six M dwarfs with known planets, we are not sensitive to planets, but can rule out the presence of all but the least massive brown dwarfs at periods of 2–12 years. For the six more astrometrically favorable M dwarfs, we conclude that none have brown dwarf companions, and are sensitive to companions with masses as low as 1 M{sub Jup} for periods longer than two years. In particular, we conclude that Proxima Centauri has no Jovian companions at orbital periods of 2–12 years. These results complement previously published M dwarf planet occurrence rates by providing astrometrically determined upper mass limits on potential super-Jupiter companions at orbits of two years and longer. As part of a continuing survey, these results are consistent with the paucity of super-Jupiter and brown dwarf companions we find among the over 250 red dwarfs within 25 pc observed longer than five years in our astrometric program.

  18. VizieR Online Data Catalog: 2007.5 to 2010.4 HST astrometry of HD 202206 (Benedict+, 2017)

    Science.gov (United States)

    Benedict, G. F.; Harrison, T. E.

    2017-08-01

    For this study astrometric measurements came from Fine Guidance Sensor 1r (FGS 1r), an upgraded FGS installed in 1997 during the second Hubble Space Telescope (HST) servicing mission. It provided superior fringes from which to obtain target and reference star positions (McArthur et al. 2003hstc.conf..373M). We utilized only the fringe tracking mode (POS mode) in this investigation. POS mode observations of a star have a typical duration of 60s, during which over 2000 individual position measures are collected. The astrometric centroid is estimated by choosing the median measure, after filtering large outliers (caused by cosmic-ray hits and particles trapped by the Earth's magnetic field). The standard deviation of the measures provides a measurement error. We refer to the aggregate of astrometric centroids of each star secured during one visibility period as an "orbit". Because one of the pillars of the scientific method involves reproducibility, we present a complete ensemble of time-tagged HD202206 and reference star astrometric measurements, Optical Field Angle Distortion (OFAD; McArthur et al. 2006hstc.conf..396M) and intra-orbit-drift-corrected, in Table2, along with calculated parallax factors in R.A. and decl. These data, collected from 2007.5 to 2010.4, in addition to providing material for confirmation of our results, might ultimately be combined with Gaia measures, significantly extending the time baseline of astrometry, thereby improving proper motion and perturbation characterization. Our band passes for reference star photometry include: BVRI photometry of the reference stars from the NMSU 1m telescope located at Apache Point Observatory and JHK (from 2MASS; see Cutri et al. 2003, Cat. II/246). Table4 lists the visible and infrared photometry for the HD202206 reference stars. To establish spectral type and luminosity class, the reference frame stars were observed on 2009 December 9 using the RCSPEC on the Blanco 4m telescope at Cerro Tololo Inter

  19. Automatic reference selection for quantitative EEG interpretation: identification of diffuse/localised activity and the active earlobe reference, iterative detection of the distribution of EEG rhythms.

    Science.gov (United States)

    Wang, Bei; Wang, Xingyu; Ikeda, Akio; Nagamine, Takashi; Shibasaki, Hiroshi; Nakamura, Masatoshi

    2014-01-01

    EEG (Electroencephalograph) interpretation is important for the diagnosis of neurological disorders. The proper adjustment of the montage can highlight the EEG rhythm of interest and avoid false interpretation. The aim of this study was to develop an automatic reference selection method to identify a suitable reference. The results may contribute to the accurate inspection of the distribution of EEG rhythms for quantitative EEG interpretation. The method includes two pre-judgements and one iterative detection module. The diffuse case is initially identified by pre-judgement 1 when intermittent rhythmic waveforms occur over large areas along the scalp. The earlobe reference or averaged reference is adopted for the diffuse case due to the effect of the earlobe reference depending on pre-judgement 2. An iterative detection algorithm is developed for the localised case when the signal is distributed in a small area of the brain. The suitable averaged reference is finally determined based on the detected focal and distributed electrodes. The presented technique was applied to the pathological EEG recordings of nine patients. One example of the diffuse case is introduced by illustrating the results of the pre-judgements. The diffusely intermittent rhythmic slow wave is identified. The effect of active earlobe reference is analysed. Two examples of the localised case are presented, indicating the results of the iterative detection module. The focal and distributed electrodes are detected automatically during the repeating algorithm. The identification of diffuse and localised activity was satisfactory compared with the visual inspection. The EEG rhythm of interest can be highlighted using a suitable selected reference. The implementation of an automatic reference selection method is helpful to detect the distribution of an EEG rhythm, which can improve the accuracy of EEG interpretation during both visual inspection and automatic interpretation. Copyright © 2013 IPEM

  20. ASTROMETRY AND RADIAL VELOCITIES OF THE PLANET HOST M DWARF GJ 317: NEW TRIGONOMETRIC DISTANCE, METALLICITY, AND UPPER LIMIT TO THE MASS OF GJ 317b

    International Nuclear Information System (INIS)

    Anglada-Escudé, Guillem; Boss, Alan P.; Weinberger, Alycia J.; Butler, R. Paul; Thompson, Ian B.; Vogt, Steven S.; Rivera, Eugenio J.

    2012-01-01

    We have obtained precision astrometry of the planet host M dwarf GJ 317 in the framework of the Carnegie Astrometric Planet Search project. The new astrometric measurements give a distance determination of 15.3 pc, 65% further than previous estimates. The resulting absolute magnitudes suggest that it is metal-rich and more massive than previously assumed. This result strengthens the correlation between high metallicity and the presence of gas giants around low-mass stars. At 15.3 pc, the minimal astrometric amplitude for planet candidate GJ 317b is 0.3 mas (edge-on orbit), just below our astrometric sensitivity. However, given the relatively large number of observations and good astrometric precision, a Bayesian Monte Carlo Markov Chain analysis indicates that the mass of planet b has to be smaller than twice the minimum mass with a 99% confidence level, with a most likely value of 2.5 M Jup . Additional radial velocity (RV) measurements obtained with Keck by the Lick-Carnegie Planet search program confirm the presence of an additional very long period planet candidate, with a period of 20 years or more. Even though such an object will imprint a large astrometric wobble on the star, its curvature is yet not evident in the astrometry. Given high metallicity, and the trend indicating that multiple systems are rich in low-mass companions, this system is likely to host additional low-mass planets in its habitable zone that can be readily detected with state-of-the-art optical and near-infrared RV measurements.

  1. ASTROMETRY AND RADIAL VELOCITIES OF THE PLANET HOST M DWARF GJ 317: NEW TRIGONOMETRIC DISTANCE, METALLICITY, AND UPPER LIMIT TO THE MASS OF GJ 317b

    Energy Technology Data Exchange (ETDEWEB)

    Anglada-Escude, Guillem; Boss, Alan P.; Weinberger, Alycia J.; Butler, R. Paul [Department of Terrestrial Magnetism, Carnegie Institution for Science, 5241 Broad Branch Road NW, Washington, DC 20015 (United States); Thompson, Ian B. [Carnegie Observatories, 813 Santa Barbara Street, Pasadena, CA 91101 (United States); Vogt, Steven S.; Rivera, Eugenio J., E-mail: anglada@dtm.ciw.edu [UCO/Lick Observatory, University of California, Santa Cruz, CA 95064 (United States)

    2012-02-10

    We have obtained precision astrometry of the planet host M dwarf GJ 317 in the framework of the Carnegie Astrometric Planet Search project. The new astrometric measurements give a distance determination of 15.3 pc, 65% further than previous estimates. The resulting absolute magnitudes suggest that it is metal-rich and more massive than previously assumed. This result strengthens the correlation between high metallicity and the presence of gas giants around low-mass stars. At 15.3 pc, the minimal astrometric amplitude for planet candidate GJ 317b is 0.3 mas (edge-on orbit), just below our astrometric sensitivity. However, given the relatively large number of observations and good astrometric precision, a Bayesian Monte Carlo Markov Chain analysis indicates that the mass of planet b has to be smaller than twice the minimum mass with a 99% confidence level, with a most likely value of 2.5 M{sub Jup}. Additional radial velocity (RV) measurements obtained with Keck by the Lick-Carnegie Planet search program confirm the presence of an additional very long period planet candidate, with a period of 20 years or more. Even though such an object will imprint a large astrometric wobble on the star, its curvature is yet not evident in the astrometry. Given high metallicity, and the trend indicating that multiple systems are rich in low-mass companions, this system is likely to host additional low-mass planets in its habitable zone that can be readily detected with state-of-the-art optical and near-infrared RV measurements.

  2. Near Infrared High Resolution Spectroscopy and Spectro-astrometry of Gas in Disks around Herbig Ae/Be Stars

    OpenAIRE

    Brittain, Sean D.; Najita, Joan R.; Carr, John S.

    2015-01-01

    In this review, we describe how high resolution near infrared spectroscopy and spectro-astrometry have been used to study the disks around Herbig~Ae/Be stars. We show how these tools can be used to identify signposts of planet formation and elucidate the mechanism by which Herbig Ae/Be stars accrete. We also highlight some of the artifacts that can complicate the interpretation of spectro-astrometric measurements and discuss best practices for mitigating these effects. We conclude with a brie...

  3. Estimating the Celestial Reference Frame via Intra-Technique Combination

    Science.gov (United States)

    Iddink, Andreas; Artz, Thomas; Halsig, Sebastian; Nothnagel, Axel

    2016-12-01

    One of the primary goals of Very Long Baseline Interferometry (VLBI) is the determination of the International Celestial Reference Frame (ICRF). Currently the third realization of the internationally adopted CRF, the ICRF3, is under preparation. In this process, various optimizations are planned to realize a CRF that does not benefit only from the increased number of observations since the ICRF2 was published. The new ICRF can also benefit from an intra-technique combination as is done for the Terrestrial Reference Frame (TRF). Here, we aim at estimating an optimized CRF by means of an intra-technique combination. The solutions are based on the input to the official combined product of the International VLBI Service for Geodesy and Astrometry (IVS), also providing the radio source parameters. We discuss the differences in the setup using a different number of contributions and investigate the impact on TRF and CRF as well as on the Earth Orientation Parameters (EOPs). Here, we investigate the differences between the combined CRF and the individual CRFs from the different analysis centers.

  4. Improving the Lane Reference Detection for Autonomous Road Vehicle Control

    Directory of Open Access Journals (Sweden)

    Felipe Jiménez

    2016-01-01

    Full Text Available Autonomous road vehicles are increasingly becoming more important and there are several techniques and sensors that are being applied for vehicle control. This paper presents an alternative system for maintaining the position of autonomous vehicles without adding additional elements to the standard sensor architecture, by using a 3D laser scanner for continuously detecting a reference element in situations in which the GNSS receiver fails or provides accuracy below the required level. Considering that the guidance variables are more accurately estimated when dealing with reference points in front of and behind the vehicle, an algorithm based on vehicle dynamics mathematical model is proposed to extend the detected points in cases where the sensor is placed at the front of the vehicle. The algorithm has been tested when driving along a lane delimited by New Jersey barriers at both sides and the results show a correct behaviour. The system is capable of estimating the reference element behind the vehicle with sufficient accuracy when the laser scanner is placed at the front of it, so the robustness of the control input variables (lateral and angular errors estimation is improved making it unnecessary to place the sensor on the vehicle roof or to introduce additional sensors.

  5. The solar neighborhood. XXXI. Discovery of an unusual red+white dwarf binary at ∼25 pc via astrometry and UV imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jao, Wei-Chun; Henry, Todd J.; Winters, Jennifer G.; Gies, Douglas R. [Department of Physics and Astronomy, Georgia State University, Atlanta, GA 30302 (United States); Subasavage, John P. [US Naval Observatory, Flagstaff Station, 10391 West Naval Observatory Road, Flagstaff, AZ 86001 (United States); Riedel, Adric R. [Department of Physics and Astronomy, Hunter College, 695 Park Avenue, New York, NY 10065 (United States); Ianna, Philip A., E-mail: jao@chara.gsu.edu, E-mail: thenry@chara.gsu.edu, E-mail: winters@chara.gsu.edu, E-mail: gies@chara.gsu.edu, E-mail: jsubasavage@nofs.navy.mil, E-mail: ar494@hunter.cuny.edu, E-mail: philianna3@gmail.com [Department of Astronomy, University of Virginia, Charlottesville, VA 22904-4325 (United States)

    2014-01-01

    We report the discovery of a nearby M5.0V dwarf at 24.6 pc, SCR 1848–6855, that is orbited by an unusual companion causing an astrometric perturbation of more than 200 mas. This is by far the largest perturbation found to date among more than 700 targets observed during our long-term astrometry/photometry program at the CTIO 0.9 m telescope. We present here a suite of astrometric, photometric, and spectroscopic observations of this high proper motion (∼1.''3 yr{sup –1}) system in an effort to reveal the nature of this unusual binary. The measured near-UV and optical U band fluxes exceed those expected for comparable M5.0V stars, and excess flux is also detected in the spectral range 4000-7000 Å. The elusive companion has been detected in HST-STIS+MAMA images at 1820 Å and 2700 Å, and our analysis shows that it is probably a rare, cool, white dwarf with T = 4600-5500 K. Given the long-term astrometric coverage, the prospects for an accurate mass determination are excellent, although as yet we can only provide limits on the unusual companion's mass.

  6. Light propagation in the gravitational field of N arbitrarily moving bodies in the 1.5PN approximation for high-precision astrometry

    Science.gov (United States)

    Zschocke, Sven

    2016-05-01

    High-precision astrometry on sub-micro-arcsecond level in angular resolution requires accurate determination of the trajectory of a light-signal from the celestial light source through the gravitational field of the Solar System toward the observer. In this investigation the light trajectory in the gravitational field of N moving bodies is determined in the 1.5 post-Newtonian approximation. In the approach presented two specific issues of particular importance are accounted for: (1) According to the recommendations of International Astronomical Union, the metric of the Solar System is expressed in terms of intrinsic mass-multipoles and intrinsic spin-multipoles of the massive bodies, allowing for arbitrary shape, inner structure and rotational motion of the massive bodies of the Solar System. (2) The Solar System bodies move along arbitrary world lines which can later be specified by Solar System ephemeris. The presented analytical solution for light trajectory is a primary requirement for extremely high-precision astrometry on sub-micro-arcsecond level of accuracy and associated massive computations in astrometric data reduction. An estimation of the numerical magnitude for time delay and light deflection of the leading multipoles is given.

  7. Reference chart for relative weight change to detect hypernatraemic dehydration

    NARCIS (Netherlands)

    Dommelen, P. van; Wouwe, J.P. van; Breuning-Boers, J.M.; Buuren, S. van; Verkerk, P.H.

    2007-01-01

    Objective: The validity of the rule of thumb that infants may have a weight loss of 10% in the first days after birth is unknown. We assessed the validity of this and other rules to detect breast-fed infants with hypernatraemic dehydration. Design: A reference chart for relative weight change was

  8. IMPROVING GALACTIC CENTER ASTROMETRY BY REDUCING THE EFFECTS OF GEOMETRIC DISTORTION

    International Nuclear Information System (INIS)

    Yelda, S.; Ghez, A. M.; Clarkson, W.; Lu, J. R.; Matthews, K.; Anderson, J.; Do, T.

    2010-01-01

    We present significantly improved proper motion measurements of the Milky Way's central stellar cluster. These improvements are made possible by refining our astrometric reference frame with a new geometric optical distortion model for the W. M. Keck II 10 m telescope's adaptive optics camera (NIRC2) in its narrow field mode. For the first time, this distortion model is constructed from on-sky measurements and is made available to the public in the form of FITS files. When applied to widely dithered images, it produces residuals in the separations of stars that are a factor of ∼3 smaller compared with the outcome using previous models. By applying this new model, along with corrections for differential atmospheric refraction, to widely dithered images of SiO masers at the Galactic center (GC), we improve our ability to tie into the precisely measured radio Sgr A*-rest frame. The resulting infrared reference frame is ∼2-3 times more accurate and stable than earlier published efforts. In this reference frame, Sgr A* is localized to within a position of 0.6 mas and a velocity of 0.09 mas yr -1 , or ∼3.4 km s -1 at 8 kpc (1σ). Also, proper motions for members of the central stellar cluster are more accurate, although less precise, due to the limited number of these wide field measurements. These proper motion measurements show that, with respect to Sgr A*, the central stellar cluster has no rotation in the plane of the sky to within 0.3 mas yr -1 arcsec -1 , has no net translational motion with respect to Sgr A* to within 0.1 mas yr -1 , and has net rotation perpendicular to the plane of the sky along the Galactic plane, as has previously been observed. While earlier proper motion studies defined a reference frame by assuming no net motion of the stellar cluster, this approach is fundamentally limited by the cluster's intrinsic dispersion and therefore will not improve with time. We define a reference frame with SiO masers and this reference frame's stability

  9. Development and field application of a nonlinear ultrasonic modulation technique for fatigue crack detection without reference data from an intact condition

    Science.gov (United States)

    Lim, Hyung Jin; Kim, Yongtak; Koo, Gunhee; Yang, Suyoung; Sohn, Hoon; Bae, In-hwan; Jang, Jeong-Hwan

    2016-09-01

    In this study, a fatigue crack detection technique, which detects a fatigue crack without relying on any reference data obtained from the intact condition of a target structure, is developed using nonlinear ultrasonic modulation and applied to a real bridge structure. Using two wafer-type lead zirconate titanate (PZT) transducers, ultrasonic excitations at two distinctive frequencies are applied to a target inspection spot and the corresponding ultrasonic response is measured by another PZT transducer. Then, the nonlinear modulation components produced by a breathing-crack are extracted from the measured ultrasonic response, and a statistical classifier, which can determine if the nonlinear modulation components are statistically significant in comparison with the background noise level, is proposed. The effectiveness of the proposed fatigue crack detection technique is experimentally validated using the data obtained from aluminum plates and aircraft fitting-lug specimens under varying temperature and loading conditions, and through a field testing of Yeongjong Grand Bridge in South Korea. The uniqueness of this study lies in that (1) detection of a micro fatigue crack with less than 1 μm width and fatigue cracks in the range of 10-20 μm in width using nonlinear ultrasonic modulation, (2) automated detection of fatigue crack formation without using reference data obtained from an intact condition, (3) reliable and robust diagnosis under varying temperature and loading conditions, (4) application of a local fatigue crack detection technique to online monitoring of a real bridge.

  10. Proceedings of the Sixth General Meeting of the International VLBI Service for Geodesy and Astrometry

    Science.gov (United States)

    Behrend, Dirk (Editor); Baver, Karen D. (Editor)

    2010-01-01

    This volume is the proceedings of the sixth General Meeting of the International VLBI Service for Geodesy and Astrometry (IVS), held in Hobart, Tasmania, Australia, February 7-13, 2010. The contents of this volume also appear on the IVS Web site at http://ivscc.gsfc.nasa.gov/publications/gm2010. The keynote of the sixth GM was the new perspectives of the next generation VLBI system under the theme "VLBI2010: From Vision to Reality". The goal of the meeting was to provide an interesting and informative program for a wide cross-section of IVS members, including station operators, program managers, and analysts. This volume contains 88 papers. All papers were edited by the editors for usage of the English language, form, and minor content-related issues.

  11. THE PHASES DIFFERENTIAL ASTROMETRY DATA ARCHIVE. II. UPDATED BINARY STAR ORBITS AND A LONG PERIOD ECLIPSING BINARY

    International Nuclear Information System (INIS)

    Muterspaugh, Matthew W.; O'Connell, J.; Hartkopf, William I.; Lane, Benjamin F.; Williamson, M.; Kulkarni, S. R.; Konacki, Maciej; Burke, Bernard F.; Colavita, M. M.; Shao, M.; Wiktorowicz, Sloane J.

    2010-01-01

    Differential astrometry measurements from the Palomar High-precision Astrometric Search for Exoplanet Systems have been combined with lower precision single-aperture measurements covering a much longer timespan (from eyepiece measurements, speckle interferometry, and adaptive optics) to determine improved visual orbits for 20 binary stars. In some cases, radial velocity observations exist to constrain the full three-dimensional orbit and determine component masses. The visual orbit of one of these binaries-α Com (HD 114378)-shows that the system is likely to have eclipses, despite its very long period of 26 years. The next eclipse is predicted to be within a week of 2015 January 24.

  12. VERSE: a novel approach to detect virus integration in host genomes through reference genome customization.

    Science.gov (United States)

    Wang, Qingguo; Jia, Peilin; Zhao, Zhongming

    2015-01-01

    Fueled by widespread applications of high-throughput next generation sequencing (NGS) technologies and urgent need to counter threats of pathogenic viruses, large-scale studies were conducted recently to investigate virus integration in host genomes (for example, human tumor genomes) that may cause carcinogenesis or other diseases. A limiting factor in these studies, however, is rapid virus evolution and resulting polymorphisms, which prevent reads from aligning readily to commonly used virus reference genomes, and, accordingly, make virus integration sites difficult to detect. Another confounding factor is host genomic instability as a result of virus insertions. To tackle these challenges and improve our capability to identify cryptic virus-host fusions, we present a new approach that detects Virus intEgration sites through iterative Reference SEquence customization (VERSE). To the best of our knowledge, VERSE is the first approach to improve detection through customizing reference genomes. Using 19 human tumors and cancer cell lines as test data, we demonstrated that VERSE substantially enhanced the sensitivity of virus integration site detection. VERSE is implemented in the open source package VirusFinder 2 that is available at http://bioinfo.mc.vanderbilt.edu/VirusFinder/.

  13. Delay in diabetic retinopathy screening increases the rate of detection of referable diabetic retinopathy.

    Science.gov (United States)

    Scanlon, P H; Aldington, S J; Stratton, I M

    2014-04-01

    To assess whether there is a relationship between delay in retinopathy screening after diagnosis of type 2 diabetes and level of retinopathy detected. Patients were referred from 88 primary care practices to an English National Health Service diabetic eye screening programme. Data for screened patients were extracted from the primary care databases using semi-automated data collection algorithms supplemented by validation processes. The programme uses two-field mydriatic digital photographs graded by a quality assured team. Data were available for 8183 screened patients with diabetes newly diagnosed in 2005, 2006 or 2007. Only 163 with type 1 diabetes were identified and were insufficient for analysis. Data were available for 8020 with newly diagnosed type 2 diabetes. Of these, 3569 were screened within 6 months, 2361 between 6 and 11 months, 1058 between 12 and 17 months, 366 between 18 and 23 months, 428 between 24 and 35 months, and 238 at 3 years or more after diagnosis. There were 5416 (67.5%) graded with no retinopathy, 1629 (20.3%) with background retinopathy in one eye, 753 (9.4%) with background retinopathy in both eyes and 222 (2.8%) had referable diabetic retinopathy. There was a significant trend (P = 0.0004) relating time from diagnosis to screening detecting worsening retinopathy. Of those screened within 6 months of diagnosis, 2.3% had referable retinopathy and, 3 years or more after diagnosis, 4.2% had referable retinopathy. The rate of detection of referable diabetic retinopathy is elevated in those who were not screened promptly after diagnosis of type 2 diabetes. © 2013 The Authors. Diabetic Medicine published by John Wiley & Sons Ltd on behalf of Diabetes UK.

  14. Less-simplified models of dark matter for direct detection and the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Choudhury, Arghya [Regional Centre for Accelerator-based Particle Physics, Harish-Chandra Research Institute,Allahabad - 211019 (India); Kowalska, Kamila; Roszkowski, Leszek; Sessolo, Enrico Maria; Williams, Andrew J. [National Centre for Nuclear Research,Hoża 69, 00-681 Warsaw (Poland)

    2016-04-29

    We construct models of dark matter with suppressed spin-independent scattering cross section utilizing the existing simplified model framework. Even simple combinations of simplified models can exhibit interference effects that cause the tree level contribution to the scattering cross section to vanish, thus demonstrating that direct detection limits on simplified models are not robust when embedded in a more complicated and realistic framework. In general for fermionic WIMP masses ≳10 GeV direct detection limits on the spin-independent scattering cross section are much stronger than those coming from the LHC. However these model combinations, which we call less-simplified models, represent situations where LHC searches become more competitive than direct detection experiments even for moderate dark matter mass. We show that a complementary use of several searches at the LHC can strongly constrain the direct detection blind spots by setting limits on the coupling constants and mediators’ mass. We derive the strongest limits for combinations of vector + scalar, vector + “squark”, and “squark” + scalar mediator, and present the corresponding projections for the LHC 14 TeV for a number of searches: mono-jet, jets + missing energy, and searches for heavy vector resonances.

  15. Less-simplified models of dark matter for direct detection and the LHC

    International Nuclear Information System (INIS)

    Choudhury, Arghya; Kowalska, Kamila; Roszkowski, Leszek; Sessolo, Enrico Maria; Williams, Andrew J.

    2016-01-01

    We construct models of dark matter with suppressed spin-independent scattering cross section utilizing the existing simplified model framework. Even simple combinations of simplified models can exhibit interference effects that cause the tree level contribution to the scattering cross section to vanish, thus demonstrating that direct detection limits on simplified models are not robust when embedded in a more complicated and realistic framework. In general for fermionic WIMP masses ≳10 GeV direct detection limits on the spin-independent scattering cross section are much stronger than those coming from the LHC. However these model combinations, which we call less-simplified models, represent situations where LHC searches become more competitive than direct detection experiments even for moderate dark matter mass. We show that a complementary use of several searches at the LHC can strongly constrain the direct detection blind spots by setting limits on the coupling constants and mediators’ mass. We derive the strongest limits for combinations of vector + scalar, vector + “squark”, and “squark” + scalar mediator, and present the corresponding projections for the LHC 14 TeV for a number of searches: mono-jet, jets + missing energy, and searches for heavy vector resonances.

  16. Less-simplified models of dark matter for direct detection and the LHC

    Science.gov (United States)

    Choudhury, Arghya; Kowalska, Kamila; Roszkowski, Leszek; Sessolo, Enrico Maria; Williams, Andrew J.

    2016-04-01

    We construct models of dark matter with suppressed spin-independent scattering cross section utilizing the existing simplified model framework. Even simple combinations of simplified models can exhibit interference effects that cause the tree level contribution to the scattering cross section to vanish, thus demonstrating that direct detection limits on simplified models are not robust when embedded in a more complicated and realistic framework. In general for fermionic WIMP masses ≳ 10 GeV direct detection limits on the spin-independent scattering cross section are much stronger than those coming from the LHC. However these model combinations, which we call less-simplified models, represent situations where LHC searches become more competitive than direct detection experiments even for moderate dark matter mass. We show that a complementary use of several searches at the LHC can strongly constrain the direct detection blind spots by setting limits on the coupling constants and mediators' mass. We derive the strongest limits for combinations of vector + scalar, vector + "squark", and "squark" + scalar mediator, and present the corresponding projections for the LHC 14 TeV for a number of searches: mono-jet, jets + missing energy, and searches for heavy vector resonances.

  17. Relative astrometry of compact flaring structures in Sgr A* with polarimetric very long baseline interferometry

    International Nuclear Information System (INIS)

    Johnson, Michael D.; Doeleman, Sheperd S.; Fish, Vincent L.; Broderick, Avery E.; Wardle, John F. C.; Marrone, Daniel P.

    2014-01-01

    We demonstrate that polarimetric interferometry can be used to extract precise spatial information about compact polarized flares of Sgr A*. We show that, for a faint dynamical component, a single interferometric baseline suffices to determine both its polarization and projected displacement from the quiescent intensity centroid. A second baseline enables two-dimensional reconstruction of the displacement, and additional baselines can self-calibrate using the flare, enhancing synthesis imaging of the quiescent emission. We apply this technique to simulated 1.3 mm wavelength observations of a 'hot spot' embedded in a radiatively inefficient accretion disk around Sgr A*. Our results indicate that, even with current sensitivities, polarimetric interferometry with the Event Horizon Telescope can achieve ∼5 μas relative astrometry of compact flaring structures near Sgr A* on timescales of minutes.

  18. An endogenous reference gene of common and durum wheat for detection of genetically modified wheat.

    Science.gov (United States)

    Imai, Shinjiro; Tanaka, Keiko; Nishitsuji, Yasuyuki; Kikuchi, Yosuke; Matsuoka, Yasuyuki; Arami, Shin-Ichiro; Sato, Megumi; Haraguchi, Hiroyuki; Kurimoto, Youichi; Mano, Junichi; Furui, Satoshi; Kitta, Kazumi

    2012-01-01

    To develop a method for detecting GM wheat that may be marketed in the near future, we evaluated the proline-rich protein (PRP) gene as an endogenous reference gene of common wheat (Triticum aestivum L.) and durum wheat (Triticum durum L.). Real-time PCR analysis showed that only DNA of wheat was amplified and no amplification product was observed for phylogenetically related cereals, indicating that the PRP detection system is specific to wheat. The intensities of the amplification products and Ct values among all wheat samples used in this study were very similar, with no nonspecific or additional amplification, indicating that the PRP detection system has high sequence stability. The limit of detection was estimated at 5 haploid genome copies. The PRP region was demonstrated to be present as a single or double copy in the common wheat haploid genome. Furthermore, the PRP detection system showed a highly linear relationship between Ct values and the amount of plasmid DNA, indicating that an appropriate calibration curve could be constructed for quantitative detection of GM wheat. All these results indicate that the PRP gene is a suitable endogenous reference gene for PCR-based detection of GM wheat.

  19. The Mass of the Candidate Exoplanet Companion to HD 33636 from Hubble Space Telescope Astrometry and High-Precision Radial Velocities

    Science.gov (United States)

    Bean, Jacob L.; McArthur, Barbara E.; Benedict, G. Fritz; Harrison, Thomas E.; Bizyaev, Dmitry; Nelan, Edmund; Smith, Verne V.

    2007-08-01

    We have determined a dynamical mass for the companion to HD 33636 that indicates it is a low-mass star instead of an exoplanet. Our result is based on an analysis of Hubble Space Telescope (HST) astrometry and ground-based radial velocity data. We have obtained high-cadence radial velocity measurements spanning 1.3 yr of HD 33636 with the Hobby-Eberly Telescope at McDonald Observatory. We combined these data with previously published velocities to create a data set that spans 9 yr. We used this data set to search for, and place mass limits on, the existence of additional companions in the HD 33636 system. Our high-precision astrometric observations of the system with the HST Fine Guidance Sensor 1r span 1.2 yr. We simultaneously modeled the radial velocity and astrometry data to determine the parallax, proper motion, and perturbation orbit parameters of HD 33636. Our derived parallax, πabs=35.6+/-0.2 mas, agrees within the uncertainties with the Hipparcos value. We find a perturbation period P=2117.3+/-0.8 days, semimajor axis aA=14.2+/-0.2 mas, and system inclination i=4.1deg+/-0.1deg. Assuming the mass of the primary star to be MA=1.02+/-0.03 Msolar, we obtain a companion mass MB=142+/-11 MJup=0.14+/-0.01 Msolar. The much larger true mass of the companion relative to its minimum mass estimated from the spectroscopic orbit parameters (Msini=9.3 MJup) is due to the nearly face-on orbit orientation. This result demonstrates the value of follow-up astrometric observations to determine the true masses of exoplanet candidates detected with the radial velocity method. Based on data obtained with the NASA/ESA Hubble Space Telescope (HST) and the Hobby-Eberly Telescope (HET). The HST observations were obtained at the Space Telescope Science Institute, which is operated by the Association of Universities for Research in Astronomy, Inc., under NASA contract NAS5-26555. The HET is a joint project of the University of Texas at Austin, Pennsylvania State University, Stanford

  20. Breaking Snake Camouflage: Humans Detect Snakes More Accurately than Other Animals under Less Discernible Visual Conditions.

    Science.gov (United States)

    Kawai, Nobuyuki; He, Hongshen

    2016-01-01

    Humans and non-human primates are extremely sensitive to snakes as exemplified by their ability to detect pictures of snakes more quickly than those of other animals. These findings are consistent with the Snake Detection Theory, which hypothesizes that as predators, snakes were a major source of evolutionary selection that favored expansion of the visual system of primates for rapid snake detection. Many snakes use camouflage to conceal themselves from both prey and their own predators, making it very challenging to detect them. If snakes have acted as a selective pressure on primate visual systems, they should be more easily detected than other animals under difficult visual conditions. Here we tested whether humans discerned images of snakes more accurately than those of non-threatening animals (e.g., birds, cats, or fish) under conditions of less perceptual information by presenting a series of degraded images with the Random Image Structure Evolution technique (interpolation of random noise). We find that participants recognize mosaic images of snakes, which were regarded as functionally equivalent to camouflage, more accurately than those of other animals under dissolved conditions. The present study supports the Snake Detection Theory by showing that humans have a visual system that accurately recognizes snakes under less discernible visual conditions.

  1. Breaking Snake Camouflage: Humans Detect Snakes More Accurately than Other Animals under Less Discernible Visual Conditions.

    Directory of Open Access Journals (Sweden)

    Nobuyuki Kawai

    Full Text Available Humans and non-human primates are extremely sensitive to snakes as exemplified by their ability to detect pictures of snakes more quickly than those of other animals. These findings are consistent with the Snake Detection Theory, which hypothesizes that as predators, snakes were a major source of evolutionary selection that favored expansion of the visual system of primates for rapid snake detection. Many snakes use camouflage to conceal themselves from both prey and their own predators, making it very challenging to detect them. If snakes have acted as a selective pressure on primate visual systems, they should be more easily detected than other animals under difficult visual conditions. Here we tested whether humans discerned images of snakes more accurately than those of non-threatening animals (e.g., birds, cats, or fish under conditions of less perceptual information by presenting a series of degraded images with the Random Image Structure Evolution technique (interpolation of random noise. We find that participants recognize mosaic images of snakes, which were regarded as functionally equivalent to camouflage, more accurately than those of other animals under dissolved conditions. The present study supports the Snake Detection Theory by showing that humans have a visual system that accurately recognizes snakes under less discernible visual conditions.

  2. Costs and consequences of automated algorithms versus manual grading for the detection of referable diabetic retinopathy.

    Science.gov (United States)

    Scotland, G S; McNamee, P; Fleming, A D; Goatman, K A; Philip, S; Prescott, G J; Sharp, P F; Williams, G J; Wykes, W; Leese, G P; Olson, J A

    2010-06-01

    To assess the cost-effectiveness of an improved automated grading algorithm for diabetic retinopathy against a previously described algorithm, and in comparison with manual grading. Efficacy of the alternative algorithms was assessed using a reference graded set of images from three screening centres in Scotland (1253 cases with observable/referable retinopathy and 6333 individuals with mild or no retinopathy). Screening outcomes and grading and diagnosis costs were modelled for a cohort of 180 000 people, with prevalence of referable retinopathy at 4%. Algorithm (b), which combines image quality assessment with detection algorithms for microaneurysms (MA), blot haemorrhages and exudates, was compared with a simpler algorithm (a) (using image quality assessment and MA/dot haemorrhage (DH) detection), and the current practice of manual grading. Compared with algorithm (a), algorithm (b) would identify an additional 113 cases of referable retinopathy for an incremental cost of pound 68 per additional case. Compared with manual grading, automated grading would be expected to identify between 54 and 123 fewer referable cases, for a grading cost saving between pound 3834 and pound 1727 per case missed. Extrapolation modelling over a 20-year time horizon suggests manual grading would cost between pound 25,676 and pound 267,115 per additional quality adjusted life year gained. Algorithm (b) is more cost-effective than the algorithm based on quality assessment and MA/DH detection. With respect to the value of introducing automated detection systems into screening programmes, automated grading operates within the recommended national standards in Scotland and is likely to be considered a cost-effective alternative to manual disease/no disease grading.

  3. VizieR Online Data Catalog: Accurate astrometry & RVs of 4 multiple systems (Tokovinin+, 2017)

    Science.gov (United States)

    Tokovinin, A.; Latham, D. W.

    2017-10-01

    The outer subsystems are classical visual binaries. Historic micrometric measurements and modern speckle interferometric data have been obtained from the WDS database on our request. Additionally, we secured new speckle astrometry and relative photometry of two systems at the 4.1m SOAR telescope. Published radial velocities (RVs) are used here together with the new data. The RVs were measured with the CfA Digital Speedometers, initially using the 1.5m Wyeth Reflector at the Oak Ridge Observatory in the town of Harvard, Massachusetts, and subsequently with the 1.5m Tillinghast Reflector at the Whipple Observatory on Mount Hopkins, Arizona. Starting in 2009, the new fiber-fed Tillinghast Reflector Echelle Spectrograph (TRES) was used. The spectral resolution was 44000 for all three spectrographs. Two objects, HIP 101955 and 103987, were observed in 2015 with the CHIRON echelle spectrograph at the 1.5m telescope at CTIO with a spectral resolution of 80000. (4 data files).

  4. Radar Astrometry of Asteroid 99942 (2004 MN4): Predicting the 2029 Earth Encounter and Beyond

    Science.gov (United States)

    Giorgini, J. D.; Benner, L. A. M.; Nolan, M. C.; Ostro, S. J.

    2005-08-01

    Asteroid 2004 MN4 is expected to pass 4.6 (+/- 1.6) Earth-radii above the surface of the Earth on 2029-Apr-13. Such close approaches by objects as large as 2004 MN4 (D ≳ 0.3 km) are thought to occur at ≳ 1000-year intervals on average. 2004 MN4 is expected to reach 3rd magnitude and thus be visible to the unaided eye. With a disk 2-4 arcseconds across, it may be resolved by ground-based telescopes. Arecibo (2380-MHz) delay-Doppler radar astrometry, obtained in late January 2005, significantly corrected 2004 MN4's orbit by revealing a 1.4 arcsecond bias in pre-discovery optical measurements. Doppler-shifted echoes were acquired 4.8σ (176.4 mm/s) away from the predicted frequency on Jan 27. Range on Jan 29 was found to be 747 km (2.8σ ) closer to Earth than the pre-radar orbit predicted. Incorporation of these delay-Doppler measurements into a new weighted least-squares orbit solution moved the 2029-Apr-13 encounter prediction 5σ closer to the Earth, illustrating the problematic nature of prediction and statistical analysis with single-apparition optical data-sets. Without delay-Doppler data, the bias was not apparent, even when optical measurements spanned a full orbit period. The current combined data-set does not permit reliable trajectory propagation to encounters beyond 2029; Monte Carlo analysis shows that, by 2036, the 3σ confidence region wraps >300 degrees of heliocentric longitude around the Sun, with some sections of this statistical region experiencing low-probability encounters with the Earth in the 2030's, gravitationally scattering some possible trajectories inward to the orbit of Venus, or outward toward Mars. Future measurements from radar opportunities in August 2005 and May 2006 (SNR ≈5-10) have the potential to eliminate statistical encounters in the 2030's. Delay-Doppler astrometry from 2013 (SNR ≈30) should permit deterministic encounter prediction through 2070, shrinking the along-track uncertainty in 2036 by two orders of magnitude

  5. Current methods of handling less-than-detectable measurements and detection limits in statistical analysis of environmental data

    International Nuclear Information System (INIS)

    Hertzler, C.L.; Atwood, C.L.; Harris, G.A.

    1989-09-01

    A search was made of statistical literature that might be applicable in environmental assessment contexts, when some of the measured quantities are reported as less than detectable (LTD). Over 60 documents were reviewed, and the findings are described in this report. The methodological areas considered are parameter estimation (point estimates and confidence intervals), tolerance intervals and prediction intervals, regression, trend analysis, comparisons of populations (including two-sample comparisons and analysis of variance), and goodness of fit tests. The conclusions are summarized at the end of the report. 68 refs., 1 tab

  6. Detection of Salmonella enterica in Meat in Less than 5 Hours by a Low-Cost and Noncomplex Sample Preparation Method

    Science.gov (United States)

    Hoorfar, J.; Hansen, F.; Christensen, J.; Mansdal, S.; Josefsen, M. H.

    2016-01-01

    ABSTRACT Salmonella is recognized as one of the most important foodborne bacteria and has wide health and socioeconomic impacts worldwide. Fresh pork meat is one of the main sources of Salmonella, and efficient and fast methods for detection are therefore necessary. Current methods for Salmonella detection in fresh meat usually include >16 h of culture enrichment, in a few cases meat, consisting of a 3-h enrichment in standard buffered peptone water and a real-time PCR-compatible sample preparation method based on filtration, centrifugation, and enzymatic digestion, followed by fast-cycling real-time PCR detection. The method was validated in an unpaired comparative study against the Nordic Committee on Food Analysis (NMKL) reference culture method 187. Pork meat samples (n = 140) were either artificially contaminated with Salmonella at 0, 1 to 10, or 10 to 100 CFU/25 g of meat or naturally contaminated. Cohen's kappa for the degree of agreement between the rapid method and the reference was 0.64, and the relative accuracy, sensitivity, and specificity for the rapid method were 81.4, 95.1, and 97.9%, respectively. The 50% limit of detections (LOD50s) were 8.8 CFU/25 g for the rapid method and 7.7 CFU/25 g for the reference method. Implementation of this method will enable faster release of Salmonella low-risk meat, providing savings for meat producers, and it will help contribute to improved food safety. IMPORTANCE While the cost of analysis and hands-on time of the presented rapid method were comparable to those of reference culture methods, the fast product release by this method can provide the meat industry with a competitive advantage. Not only will the abattoirs save costs for work hours and cold storage, but consumers and retailers will also benefit from fresher meat with a longer shelf life. Furthermore, the presented sample preparation might be adjusted for application in the detection of other pathogenic bacteria in different sample types. PMID:27986726

  7. NO Detection by Pulsed Polarization of Lambda Probes–Influence of the Reference Atmosphere

    Directory of Open Access Journals (Sweden)

    Sabine Fischer

    2013-11-01

    Full Text Available The pulsed polarization measurement technique using conventional thimble type lambda probes is suitable for low ppm NOx detection in exhaust gas applications. To evaluate the underlying sensor mechanism, the unknown influence of the reference atmosphere on the NO sensing behavior is investigated in this study. Besides answering questions with respect to the underlying principle, this investigation can resolve the main question of whether a simplified sensor element without reference may be also suitable for NO sensing using the pulsed polarization measurement technique. With an adequate sensor setup, the reference atmosphere of the thimble type lambda probe is changed completely after a certain diffusion time. Thus, the sensor response regarding NO is compared with and without different gas atmospheres on both electrodes. It is shown that there is still a very good NO sensitivity even without reference air, although the NO response is reduced due to non-existing overlying mixed potential type voltage, which is otherwise caused by different atmospheres on both electrodes. Considering these results, we see an opportunity to simplify the standard NOx sensor design by omitting the reference electrode.

  8. A new methodology for automatic detection of reference points in 3D cephalometry: A pilot study.

    Science.gov (United States)

    Ed-Dhahraouy, Mohammed; Riri, Hicham; Ezzahmouly, Manal; Bourzgui, Farid; El Moutaoukkil, Abdelmajid

    2018-04-05

    The aim of this study was to develop a new method for an automatic detection of reference points in 3D cephalometry to overcome the limits of 2D cephalometric analyses. A specific application was designed using the C++ language for automatic and manual identification of 21 (reference) points on the craniofacial structures. Our algorithm is based on the implementation of an anatomical and geometrical network adapted to the craniofacial structure. This network was constructed based on the anatomical knowledge of the 3D cephalometric (reference) points. The proposed algorithm was tested on five CBCT images. The proposed approach for the automatic 3D cephalometric identification was able to detect 21 points with a mean error of 2.32mm. In this pilot study, we propose an automated methodology for the identification of the 3D cephalometric (reference) points. A larger sample will be implemented in the future to assess the method validity and reliability. Copyright © 2018 CEO. Published by Elsevier Masson SAS. All rights reserved.

  9. On detecting reference level of acrolein content in children's blood

    Directory of Open Access Journals (Sweden)

    T.S. Ulanova

    2017-03-01

    Full Text Available The article gives the results of complex chemical-analytical and clinical-laboratory research in course of which biological media of children living in Perm region were examined. To study impacts exerted by exogenous acrolein we examined 156 children in 2014–2016, aged 5–10, attending pre-school facilities and schools, and living in Perm region. As we conducted this research we detected average annual acrolein concentration in atmosphere on the examined territory; this concentration was equal to 0.000024 mg/m3, and it was 1.2 times higher than reference acrolein concentration in the air for chronic inhalation exposure. Average group acrolein concentration in children's blood was 1.2 times authentically higher (р3.96, p≤0.05. We used increased content of delta-aminolevulinic acid in urine as a limiting marker for effects occurring at chronic inhalation exposure to acrolein. Basing on the results of the performed examination we recommend concentration equal to 0.10 mgr/dm 3 as a reference level of acrolein content in blood at chronic inhalation exposure.

  10. Application of the Allan Variance to Time Series Analysis in Astrometry and Geodesy: A Review.

    Science.gov (United States)

    Malkin, Zinovy

    2016-04-01

    The Allan variance (AVAR) was introduced 50 years ago as a statistical tool for assessing the frequency standards deviations. For the past decades, AVAR has increasingly been used in geodesy and astrometry to assess the noise characteristics in geodetic and astrometric time series. A specific feature of astrometric and geodetic measurements, as compared with clock measurements, is that they are generally associated with uncertainties; thus, an appropriate weighting should be applied during data analysis. In addition, some physically connected scalar time series naturally form series of multidimensional vectors. For example, three station coordinates time series X, Y, and Z can be combined to analyze 3-D station position variations. The classical AVAR is not intended for processing unevenly weighted and/or multidimensional data. Therefore, AVAR modifications, namely weighted AVAR (WAVAR), multidimensional AVAR (MAVAR), and weighted multidimensional AVAR (WMAVAR), were introduced to overcome these deficiencies. In this paper, a brief review is given of the experience of using AVAR and its modifications in processing astrogeodetic time series.

  11. Demadroid: Object Reference Graph-Based Malware Detection in Android

    Directory of Open Access Journals (Sweden)

    Huanran Wang

    2018-01-01

    Full Text Available Smartphone usage has been continuously increasing in recent years. In addition, Android devices are widely used in our daily life, becoming the most attractive target for hackers. Therefore, malware analysis of Android platform is in urgent demand. Static analysis and dynamic analysis methods are two classical approaches. However, they also have some drawbacks. Motivated by this, we present Demadroid, a framework to implement the detection of Android malware. We obtain the dynamic information to build Object Reference Graph and propose λ-VF2 algorithm for graph matching. Extensive experiments show that Demadroid can efficiently identify the malicious features of malware. Furthermore, the system can effectively resist obfuscated attacks and the variants of known malware to meet the demand for actual use.

  12. Selection of Suitable Endogenous Reference Genes for Relative Copy Number Detection in Sugarcane

    Directory of Open Access Journals (Sweden)

    Bantong Xue

    2014-05-01

    Full Text Available Transgene copy number has a great impact on the expression level and stability of exogenous gene in transgenic plants. Proper selection of endogenous reference genes is necessary for detection of genetic components in genetically modification (GM crops by quantitative real-time PCR (qPCR or by qualitative PCR approach, especially in sugarcane with polyploid and aneuploid genomic structure. qPCR technique has been widely accepted as an accurate, time-saving method on determination of copy numbers in transgenic plants and on detection of genetically modified plants to meet the regulatory and legislative requirement. In this study, to find a suitable endogenous reference gene and its real-time PCR assay for sugarcane (Saccharum spp. hybrids DNA content quantification, we evaluated a set of potential “single copy” genes including P4H, APRT, ENOL, CYC, TST and PRR, through qualitative PCR and absolute quantitative PCR. Based on copy number comparisons among different sugarcane genotypes, including five S. officinarum, one S. spontaneum and two S. spp. hybrids, these endogenous genes fell into three groups: ENOL-3—high copy number group, TST-1 and PRR-1—medium copy number group, P4H-1, APRT-2 and CYC-2—low copy number group. Among these tested genes, P4H, APRT and CYC were the most stable, while ENOL and TST were the least stable across different sugarcane genotypes. Therefore, three primer pairs of P4H-3, APRT-2 and CYC-2 were then selected as the suitable reference gene primer pairs for sugarcane. The test of multi-target reference genes revealed that the APRT gene was a specific amplicon, suggesting this gene is the most suitable to be used as an endogenous reference target for sugarcane DNA content quantification. These results should be helpful for establishing accurate and reliable qualitative and quantitative PCR analysis of GM sugarcane.

  13. Development of dual PZT transducers for reference-free crack detection in thin plate structures.

    Science.gov (United States)

    Sohn, Hoon; Kim, Seuno Bum

    2010-01-01

    A new Lamb-wave-based nondestructive testing (NDT) technique, which does not rely on previously stored baseline data, is developed for crack monitoring in plate structures. Commonly, the presence of damage is identified by comparing "current data" measured from a potentially damaged stage of a structure with "baseline data" previously obtained at the intact condition of the structure. In practice, structural defects typically take place long after collection of the baseline data, and the baseline data can be also affected by external loading, temperature variations, and changing boundary conditions. To eliminate the dependence on the baseline data comparison, the authors previously developed a reference-free NDT technique using 2 pairs of collocated lead zirconate titanate (PZT) transducers placed on both sides of a plate. This reference-free technique is further advanced in the present study by the necessity of attaching transducers only on a single surface of a structure for certain applications such as aircraft. To achieve this goal, a new design of PZT transducers called dual PZT transducers is proposed. Crack formation creates Lamb wave mode conversion due to a sudden thickness change of the structure. This crack appearance is instantly detected from the measured Lamb wave signals using the dual PZT transducers. This study also suggests a reference-free statistical approach that enables damage classification using only the currently measured data set. Numerical simulations and experiments were conducted using an aluminum plate with uniform thickness and fundamental Lamb waves modes to demonstrate the applicability of the proposed technique to reference-free crack detection.

  14. Critical care providers refer to information tools less during communication tasks after a critical care clinical information system introduction.

    Science.gov (United States)

    Ballermann, Mark; Shaw, Nicola T; Mayes, Damon C; Gibney, R T Noel

    2011-01-01

    Electronic documentation methods may assist critical care providers with information management tasks in Intensive Care Units (ICUs). We conducted a quasi-experimental observational study to investigate patterns of information tool use by ICU physicians, nurses, and respiratory therapists during verbal communication tasks. Critical care providers used tools less at 3 months after the CCIS introduction. At 12 months, care providers referred to paper and permanent records, especially during shift changes. The results suggest potential areas of improvement for clinical information systems in assisting critical care providers in ensuring informational continuity around their patients.

  15. An analog cell to detect single event transients in voltage references

    Energy Technology Data Exchange (ETDEWEB)

    Franco, F.J., E-mail: fjfranco@fis.ucm.es [Departamento de Física Aplicada III, Facultad de Físicas, Universidad Complutense de Madrid (UCM), 28040 Madrid (Spain); Palomar, C. [Departamento de Física Aplicada III, Facultad de Físicas, Universidad Complutense de Madrid (UCM), 28040 Madrid (Spain); Izquierdo, J.G. [Centro de Láseres Ultrarrápidos, Facultad de Químicas, Universidad Complutense de Madrid (UCM), 28040 Madrid (Spain); Agapito, J.A. [Departamento de Física Aplicada III, Facultad de Físicas, Universidad Complutense de Madrid (UCM), 28040 Madrid (Spain)

    2015-01-11

    A reliable voltage reference is mandatory in mixed-signal systems. However, this family of components can undergo very long single event transients when operating in radiation environments such as space and nuclear facilities due to the impact of heavy ions. The purpose of the present paper is to demonstrate how a simple cell can be used to detect these transients. The cell was implemented with typical COTS components and its behavior was verified by SPICE simulations and in a laser facility. Different applications of the cell are explored as well.

  16. Semantic-less Breach Detection of Polymorphic Malware in Federated Cloud

    Directory of Open Access Journals (Sweden)

    Yahav Biran

    2017-06-01

    Full Text Available Cloud computing is one of the largest emerging utility services that is expected to grow enormously over the next decade. Many organizations are moving into hybrid cloud/hosted computing models. Single cloud service provider introduces cost and environmental challenges. Also, multi-cloud solution implemented by the Cloud tenant is suboptimal as it requires expensive adaptation costs. Cloud Federation is a useful structure for aggregating cloud based services under a single umbrella to share resources and responsibilities for the benefit of the member cloud service providers. An efficient security model is crucial for successful cloud business. However, with the advent of large scale and multi-tenant environments, the traditional perimeter boundaries along with traditional security practices are changing. Defining and securing asset and enclave boundaries is more challenging, and system perimeter boundaries are more susceptible to breach. This paper to describe security best practices for Cloud Federation. The paper also describes a tool and technique for detecting anomalous behavior in resource usage across the federation participants. This is a particularly serious issue because of the possibility of an attacker potentially gaining access to more than one CSP federation member. Specifically, this technique is developed for Cloud Federations since they have to deal with heterogeneous multi-platform environments with a diverse mixture of data and security log schema, and it has to do this in real time. A Semantic-less Breach detection system that implements a self-learning system was prototyped and resulted in up to 87% True-Positive rate with 93% True-Negative.

  17. "The refer less resolve more" initiative: A five-year experience from CMC Vellore, India

    Directory of Open Access Journals (Sweden)

    Jachin Velavan

    2012-01-01

    Full Text Available India′s one billion plus strong population presents huge health care needs. Presently, approximately 250,000 general practitioners and 30,000 Government doctors are a part of the Indian healthcare workforce, but 80% of them are based in urban India. Problems which plague healthcare delivery and attributed to physician practice may be enumerated as - physicians (1 lack competencies, (2 lack updating, (3 prescribe irrationally (pressures from pharmaceutical companies and patients, (4 practice unethically, (5 refer excessively to specialists and other clinical professionals, and (6 investigate for diseases without justification. A multi-competent Family Physician who could provide a single-window, ethical, and holistic healthcare to patients and families is the need of the hour. Therefore, training, equipping, and empowering these 250,000 doctors to become such physicians will reduce health costs considerably. Distance medical education using all the andragogic methods can be used to train large number of individuals without displacing them from their work-places. Distance learning provides a useful interface for rapidly developing a specialized pool of doctors practicing and advocating family medicine as most-needed discipline. This motivated CMC Vellore, a premier institution for medical education in India, to start a the "refer less resolve more initiative" by offering "two year family medicine diploma course" by distance mode. This is an innovatively-written program consisting of problem-based self-learning modules, video-lectures, video-conferencing, and face-to-face contact programs. Ten secondary level hospitals, across the country, under the supervision of national and international family medicine faculty form the pillars of this program. This distance learning program offered by CMC Vellore has become the platform for change as there is special focus is on ethics, rational prescribing, consultation skills, application of family medicine

  18. "The Refer Less Resolve More" Initiative: A Five-year Experience from CMC Vellore, India.

    Science.gov (United States)

    Velavan, Jachin

    2012-01-01

    India's one billion plus strong population presents huge health care needs. Presently, approximately 250,000 general practitioners and 30,000 Government doctors are a part of the Indian healthcare workforce, but 80% of them are based in urban India. Problems which plague healthcare delivery and attributed to physician practice may be enumerated as - physicians (1) lack competencies, (2) lack updating, (3) prescribe irrationally (pressures from pharmaceutical companies and patients), (4) practice unethically, (5) refer excessively to specialists and other clinical professionals, and (6) investigate for diseases without justification. A multi-competent Family Physician who could provide a single-window, ethical, and holistic healthcare to patients and families is the need of the hour. Therefore, training, equipping, and empowering these 250,000 doctors to become such physicians will reduce health costs considerably. Distance medical education using all the andragogic methods can be used to train large number of individuals without displacing them from their work-places. Distance learning provides a useful interface for rapidly developing a specialized pool of doctors practicing and advocating family medicine as most-needed discipline. This motivated CMC Vellore, a premier institution for medical education in India, to start a the "refer less resolve more initiative" by offering "two year family medicine diploma course" by distance mode. This is an innovatively-written program consisting of problem-based self-learning modules, video-lectures, video-conferencing, and face-to-face contact programs. Ten secondary level hospitals, across the country, under the supervision of national and international family medicine faculty form the pillars of this program. This distance learning program offered by CMC Vellore has become the platform for change as there is special focus is on ethics, rational prescribing, consultation skills, application of family medicine principles

  19. A Long Journey of Mathematics and Astronomy in Romania

    Science.gov (United States)

    Stavinschi, Magda

    2010-10-01

    Bucharest Astronomical Observatory celebrated recently its centenary. Its founders were all mathematicians or, better said, astronomers specialized in celestial mechanics. Their first doctoral theses were defended at Sorbonne, in the second half of the 19th century, under the guidance of the greatest specialists of the time. After they returned home, they continued what they had begun in Paris, namely celestial mechanics. The instruments they ordered and the first programmes of astronomical observations had an increasingly closer relation to mathematics, as they referred to astrometry and especially to stellar catalogues. Naturally, there were also astrophysical concerns, timid ones in the beginning, and then ever larger, especially beginning with the International Geophysical Year. The evolution of world astronomy, as well as that of Romania, seems to be following but one direction: astrophysics. The truth is that astrometry and celestial mechanics continue to lie at the basis of all astrophysical researches, actually in an entirely new and modern form. The astrometry schools recently organized, the new astrometry textbooks, as well as the IAU working groups dedicated to modern astrometry prove that the long journey of mathematics and astronomy is not over yet.

  20. Automated analysis of retinal images for detection of referable diabetic retinopathy.

    Science.gov (United States)

    Abràmoff, Michael D; Folk, James C; Han, Dennis P; Walker, Jonathan D; Williams, David F; Russell, Stephen R; Massin, Pascale; Cochener, Beatrice; Gain, Philippe; Tang, Li; Lamard, Mathieu; Moga, Daniela C; Quellec, Gwénolé; Niemeijer, Meindert

    2013-03-01

    The diagnostic accuracy of computer detection programs has been reported to be comparable to that of specialists and expert readers, but no computer detection programs have been validated in an independent cohort using an internationally recognized diabetic retinopathy (DR) standard. To determine the sensitivity and specificity of the Iowa Detection Program (IDP) to detect referable diabetic retinopathy (RDR). In primary care DR clinics in France, from January 1, 2005, through December 31, 2010, patients were photographed consecutively, and retinal color images were graded for retinopathy severity according to the International Clinical Diabetic Retinopathy scale and macular edema by 3 masked independent retinal specialists and regraded with adjudication until consensus. The IDP analyzed the same images at a predetermined and fixed set point. We defined RDR as more than mild nonproliferative retinopathy and/or macular edema. A total of 874 people with diabetes at risk for DR. Sensitivity and specificity of the IDP to detect RDR, area under the receiver operating characteristic curve, sensitivity and specificity of the retinal specialists' readings, and mean interobserver difference (κ). The RDR prevalence was 21.7% (95% CI, 19.0%-24.5%). The IDP sensitivity was 96.8% (95% CI, 94.4%-99.3%) and specificity was 59.4% (95% CI, 55.7%-63.0%), corresponding to 6 of 874 false-negative results (none met treatment criteria). The area under the receiver operating characteristic curve was 0.937 (95% CI, 0.916-0.959). Before adjudication and consensus, the sensitivity/specificity of the retinal specialists were 0.80/0.98, 0.71/1.00, and 0.91/0.95, and the mean intergrader κ was 0.822. The IDP has high sensitivity and specificity to detect RDR. Computer analysis of retinal photographs for DR and automated detection of RDR can be implemented safely into the DR screening pipeline, potentially improving access to screening and health care productivity and reducing visual loss

  1. Applying Information Retrieval Techniques to Detect Duplicates and to Rank References in the Preliminary Phases of Systematic Literature Reviews

    Directory of Open Access Journals (Sweden)

    Ramon Abilio

    2015-08-01

    Full Text Available Systematic Literature Review (SLR is a means to synthesize relevant and high quality studies related to a specific topic or research questions. In the Primary Selection stage of an SLR, the selection of studies is usually performed manually by reading title, abstract and keywords of each study. In the last years, the number of published scientific studies has grown increasing the effort to perform this sort of reviews. In this paper, we proposed strategies to detect non-papers and duplicated references in results exported by search engines, and strategies to rank the references in decreasing order of importance for an SLR, regarding the terms in the search string. These strategies are based on Information Retrieval techniques. We implemented the strategies and carried out an experimental evaluation of their applicability using two real datasets. As results, the strategy to detect non-papers presented 100% of precision and 50% of recall; the strategy to detect duplicates detected more duplicates than the manual inspection; and one of the strategies to rank relevant references presented 50% of precision and 80% of recall. Therefore, the results show that the proposed strategies can minimize the effort in the Primary Selection stage of an SLR.

  2. VLBI: A Fascinating Technique for Geodesy and Astrometry

    Science.gov (United States)

    Schuh, H.; Behrend, Dirk

    2012-01-01

    Since the 1970s Very Long Baseline Interferometry (VLBI) has proven to be a primary space-geodetic technique by determining precise coordinates on the Earth, by monitoring the variable Earth rotation and orientation with highest precision, and by deriving many other parameters of the Earth system. VLBI provides an important linkage to astronomy through, for instance, the determination of very precise coordinates of extragalactic radio sources. Additionally, it contributes to determining parameters of relativistic and cosmological models. After a short review of the history of geodetic VLBI and a summary of recent results, this paper describes future perspectives of this fascinating technique. The International VLBI Service for Geodesy and Astrometry (IVS), as a service of the International Association of Geodesy (IAG) and the International Astronomical Union (IAU), is well on its way to fully defining a next generation VLBI system, called VLBI2010. The goals of the new system are to achieve on scales up to the size of the Earth an accuracy of 1 mm in position and of 0.1 mm/year in velocity. Continuous observations shall be carried out 24 h per day 7 days per week in the future with initial results to be delivered within 24 h after taking the data. Special sessions, e.g. for monitoring the Earth rotation parameters, will provide the results in near real-time. These goals require a completely new technical and conceptual design of VLBI measurements. Based on extensive simulation studies, strategies have been developed by the IVS to significantly improve its product accuracy through the use of a network of small (approx 12 m) fast-slewing antennas. A new method for generating high precision delay measurements as well as improved methods for handling biases related to radio source structure, system electronics, and deformations of the antenna structures has been developed. Furthermore, as of January 2012, the construction of ten new VLBI2010 sites has been funded, with

  3. A novel SNP analysis method to detect copy number alterations with an unbiased reference signal directly from tumor samples

    Directory of Open Access Journals (Sweden)

    LaFramboise William A

    2011-01-01

    Full Text Available Abstract Background Genomic instability in cancer leads to abnormal genome copy number alterations (CNA as a mechanism underlying tumorigenesis. Using microarrays and other technologies, tumor CNA are detected by comparing tumor sample CN to normal reference sample CN. While advances in microarray technology have improved detection of copy number alterations, the increase in the number of measured signals, noise from array probes, variations in signal-to-noise ratio across batches and disparity across laboratories leads to significant limitations for the accurate identification of CNA regions when comparing tumor and normal samples. Methods To address these limitations, we designed a novel "Virtual Normal" algorithm (VN, which allowed for construction of an unbiased reference signal directly from test samples within an experiment using any publicly available normal reference set as a baseline thus eliminating the need for an in-lab normal reference set. Results The algorithm was tested using an optimal, paired tumor/normal data set as well as previously uncharacterized pediatric malignant gliomas for which a normal reference set was not available. Using Affymetrix 250K Sty microarrays, we demonstrated improved signal-to-noise ratio and detected significant copy number alterations using the VN algorithm that were validated by independent PCR analysis of the target CNA regions. Conclusions We developed and validated an algorithm to provide a virtual normal reference signal directly from tumor samples and minimize noise in the derivation of the raw CN signal. The algorithm reduces the variability of assays performed across different reagent and array batches, methods of sample preservation, multiple personnel, and among different laboratories. This approach may be valuable when matched normal samples are unavailable or the paired normal specimens have been subjected to variations in methods of preservation.

  4. Identification of pyrG Used as an Endogenous Reference Gene in Qualitative and Real-Time Quantitative PCR Detection of Pleurotus ostreatus.

    Science.gov (United States)

    Zheng, Shi; Shan, Luying; Zhuang, Yongliang; Shang, Ying

    2018-03-01

    As a well-known edible fungus rich in nutrients, Pleurotus ostreatus has been used as an alternative to expensive wild edible fungi. Specifically, the fact that using P. ostreatus instead of other expensive wild edible fungi has damaged the rights and interests of consumers. Among the existing methods for detection of food adulteration, the amplification of endogenous reference gene is the most accurate method. However, an ideal endogenous reference gene for P. ostreatus has yet to be developed. In this study, a DNA extraction method for P. ostreatus was optimized, and pyrG was selected as a species-specific gene through sequence alignment. This gene was subsequently subjected to qualitative and quantitative Polymerase Chain Reaction (PCR) assays with 3 different P. ostreatus varieties and 7 other species. A low detection limit of 5 pg/μL was obtained by TaqMan quantitative PCR, and no pyrG amplification product was observed in the 7 other species. No allelic variation was detected in P. ostreatus varieties. These experiments confirmed that pyrG was an ideal endogenous reference gene for the qualitative and real-time quantitative PCR detection of P. ostreatus. This method was also suitable for the examination of processed P. ostreatus samples and determination of adulteration in wild mushrooms. The pyrG gene was chosen as an ideal endogenous reference gene for the qualitative and real-time quantitative PCR detection of P. ostreatus, and the detection limit was 5 pg/μL for the quantification. This method is used not only for raw materials but also for processed P. ostreatus products and other processed mushroom foods. © 2018 Institute of Food Technologists®.

  5. Local exome sequences facilitate imputation of less common variants and increase power of genome wide association studies.

    Directory of Open Access Journals (Sweden)

    Peter K Joshi

    Full Text Available The analysis of less common variants in genome-wide association studies promises to elucidate complex trait genetics but is hampered by low power to reliably detect association. We show that addition of population-specific exome sequence data to global reference data allows more accurate imputation, particularly of less common SNPs (minor allele frequency 1-10% in two very different European populations. The imputation improvement corresponds to an increase in effective sample size of 28-38%, for SNPs with a minor allele frequency in the range 1-3%.

  6. OPTICAL SPECTRA OF CANDIDATE INTERNATIONAL CELESTIAL REFERENCE FRAME (ICRF) FLAT-SPECTRUM RADIO SOURCES

    Energy Technology Data Exchange (ETDEWEB)

    Titov, O.; Stanford, Laura M. [Geoscience Australia, P.O. Box 378, Canberra, ACT 2601 (Australia); Johnston, Helen M.; Hunstead, Richard W. [Sydney Institute for Astronomy, School of Physics, University of Sydney, NSW 2006 (Australia); Pursimo, T. [Nordic Optical Telescope, Nordic Optical Telescope Apartado 474E-38700 Santa Cruz de La Palma, Santa Cruz de Tenerife (Spain); Jauncey, David L. [CSIRO Astronomy and Space Science, ATNF and Research School of Astronomy and Astrophysics, Australian National University, Canberra, ACT 2611 (Australia); Maslennikov, K. [Central Astronomical Observatory at Pulkovo, Pulkovskoye Shosse, 65/1, 196140, St. Petersburg (Russian Federation); Boldycheva, A., E-mail: oleg.titov@ga.gov.au [Ioffe Physical Technical Institute, 26 Polytekhnicheskaya, St. Petersburg, 194021 (Russian Federation)

    2013-07-01

    Continuing our program of spectroscopic observations of International Celestial Reference Frame (ICRF) sources, we present redshifts for 120 quasars and radio galaxies. Data were obtained with five telescopes: the 3.58 m European Southern Observatory New Technology Telescope, the two 8.2 m Gemini telescopes, the 2.5 m Nordic Optical Telescope (NOT), and the 6.0 m Big Azimuthal Telescope of the Special Astrophysical Observatory in Russia. The targets were selected from the International VLBI Service for Geodesy and Astrometry candidate International Celestial Reference Catalog which forms part of an observational very long baseline interferometry (VLBI) program to strengthen the celestial reference frame. We obtained spectra of the potential optical counterparts of more than 150 compact flat-spectrum radio sources, and measured redshifts of 120 emission-line objects, together with 19 BL Lac objects. These identifications add significantly to the precise radio-optical frame tie to be undertaken by Gaia, due to be launched in 2013, and to the existing data available for analyzing source proper motions over the celestial sphere. We show that the distribution of redshifts for ICRF sources is consistent with the much larger sample drawn from Faint Images of the Radio Sky at Twenty cm (FIRST) and Sloan Digital Sky Survey, implying that the ultra-compact VLBI sources are not distinguished from the overall radio-loud quasar population. In addition, we obtained NOT spectra for five radio sources from the FIRST and NRAO VLA Sky Survey catalogs, selected on the basis of their red colors, which yielded three quasars with z > 4.

  7. Bacteriological detection of Salmonella in the presence of competitive micro-organisms (A collaborative study amongst the National Reference Laboratories for Salmonella)

    NARCIS (Netherlands)

    Voogt N; Veld PH in 't; Nagelkerke N; Henken AM; MGB

    1997-01-01

    A second bacteriological collaborative study in which the National Reference Laboratories (NRLs) for Salmonella participated was organized by the Community Reference Laboratory for Salmonella. The main objective of this study was to evaluate differences in results between the NRLs of detection of

  8. Computation of a Reference Model for Robust Fault Detection and Isolation Residual Generation

    Directory of Open Access Journals (Sweden)

    Emmanuel Mazars

    2008-01-01

    Full Text Available This paper considers matrix inequality procedures to address the robust fault detection and isolation (FDI problem for linear time-invariant systems subject to disturbances, faults, and polytopic or norm-bounded uncertainties. We propose a design procedure for an FDI filter that aims to minimize a weighted combination of the sensitivity of the residual signal to disturbances and modeling errors, and the deviation of the faults to residual dynamics from a fault to residual reference model, using the ℋ∞-norm as a measure. A key step in our procedure is the design of an optimal fault reference model. We show that the optimal design requires the solution of a quadratic matrix inequality (QMI optimization problem. Since the solution of the optimal problem is intractable, we propose a linearization technique to derive a numerically tractable suboptimal design procedure that requires the solution of a linear matrix inequality (LMI optimization. A jet engine example is employed to demonstrate the effectiveness of the proposed approach.

  9. Sensor for metal detection

    KAUST Repository

    Kodzius, Rimantas

    2014-06-26

    NOVELTY - The sensor has a microfluidic flow channel that is provided with an inlet port, an outlet port, and a detection chamber. The detection chamber is provided with a group of sensing electrodes (4) having a working electrode (8), a counter electrode (9), and a reference electrode (10). A flow sensor is configured to measure flow in the channel. A temperature sensor (6) is configured to measure temperature in the channel (3). An electrical connection is configured to connect the sensor to a sensing device. USE - Sensor for detecting metal such as toxic metal in sample such as clinical sample such as stool, saliva, sputum, bronchial lavage, urine, vaginal swab, nasal swab, biopsy, tissue, tears, breath, blood, serum, plasma, cerebrospinal fluid, peritoneal fluid, pleural fluid, pericardial fluid, joint fluid, and amniotic fluid, water sample, food sample, air sample, and soil sample (all claimed). ADVANTAGE - The sensor for use with the portable analytical instrument is configured for detection of metalsin samples. The sensor can provide the excellent solution for on-site metal detection, including heavy metal detection. The sensors can provide significant advantages in higher throughput, lower cost, at the same time being less labor intensive and less dependent on individual skills. The disposable design of the sensor, the enhanced reliability and repeatability of measurements can be obtained. The sensors can be widely applied in various industries. DETAILED DESCRIPTION - INDEPENDENT CLAIMS are included for the following: (1) a system for detecting metal in sample; and (2) a method for using sensor for detecting metal in sample. DESCRIPTION OF DRAWING(S) - The drawing shows a schematic view of the sensor prototype. Channel (3) Sensing electrodes (4) Temperature sensor (6) Working electrode (8) Counter electrode (9) Reference electrode (10)

  10. Use of Liquid Chromatography with Electrochemical Detection for the Determination of Antioxidants in Less Common Fruits

    Directory of Open Access Journals (Sweden)

    Zbynek Gazdik

    2008-11-01

    Full Text Available Neurodegenerative disorders (NDD have become the common global health burden over the last several decades. According to World Health Organization (WHO, a staggering 30 million people will be affected by Alzheimer’s disease in Europe and the USA by 2050. Effective therapies in this complex field considering the multitude of symptoms associated with NDD indications, have not been found yet. Based on the results of NDD related studies, prevention appears to be the promise alternative. Antioxidative and anti-inflammatory properties are hypothesized for natural phenolics, a group of plant secondary products that may positively impact neurodegenerative diseases. In these studies, phenolic-rich extracts from less common fruit species: Blue honeysuckle (Lonicera edulis, Turcz. ex. Freyn, Saskatoon berry (Amelanchier alnifolia Nutt., and Chinese hawthorn (Crateagus pinnatifida Bunge were obtained and analyzed to detect neuroprotective substances content and establish a potential therapeutic value. High performance liquid chromatography with electrochemical detection was optimized and further applied on analysis of the extracts of less common fruit species. It was observed that Chinese hawthorn and Blue honeysuckle extracts are potent source of neuroprotective phenolic antioxidants. In accordance the results, it appears that the fruit or formulated products may have the potential for the prevention of neurodegenerative diseases.

  11. Micro-Arcsec mission: implications of the monitoring, diagnostic and calibration of the instrument response in the data reduction chain. .

    Science.gov (United States)

    Busonero, D.; Gai, M.

    The goals of 21st century high angular precision experiments rely on the limiting performance associated to the selected instrumental configuration and observational strategy. Both global and narrow angle micro-arcsec space astrometry require that the instrument contributions to the overall error budget has to be less than the desired micro-arcsec level precision. Appropriate modelling of the astrometric response is required for optimal definition of the data reduction and calibration algorithms, in order to ensure high sensitivity to the astrophysical source parameters and in general high accuracy. We will refer to the framework of the SIM-Lite and the Gaia mission, the most challenging space missions of the next decade in the narrow angle and global astrometry field, respectively. We will focus our dissertation on the Gaia data reduction issues and instrument calibration implications. We describe selected topics in the framework of the Astrometric Instrument Modelling for the Gaia mission, evidencing their role in the data reduction chain and we give a brief overview of the Astrometric Instrument Model Data Analysis Software System, a Java-based pipeline under development by our team.

  12. THE SYNERGY OF DIRECT IMAGING AND ASTROMETRY FOR ORBIT DETERMINATION OF EXO-EARTHS

    International Nuclear Information System (INIS)

    Shao, Michael; Catanzarite, Joseph; Pan Xiaopei

    2010-01-01

    The holy grail of exoplanet searches is an exo-Earth, an Earth mass planet in the habitable zone (HZ) around a nearby star. Mass is one of the most important characteristics of a planet and can only be measured by observing the motion of the star around the planet-star center of gravity. The planet's orbit can be measured either by imaging the planet at multiple epochs or by measuring the position of the star at multiple epochs by space-based astrometry. The measurement of an exoplanet's orbit by direct imaging is complicated by a number of factors. One is the inner working angle (IWA). A space coronagraph or interferometer imaging an exo-Earth can separate the light from the planet from the light from the star only when the star-planet separation is larger than the IWA. Second, the apparent brightness of a planet depends on the orbital phase. A single image of a planet cannot tell us whether the planet is in the HZ or distinguish whether it is an exo-Earth or a Neptune-mass planet. Third is the confusion that may arise from the presence of multiple planets. With two images of a multiple planet system, it is not possible to assign a dot to a planet based only on the photometry and color of the planet. Finally, the planet-star contrast must exceed a certain minimum value in order for the planet to be detected. The planet may be unobservable even when it is outside the IWA, such as when the bright side of the planet is facing away from us in a 'crescent' phase. In this paper we address the question: 'Can a prior astrometric mission that can identify which stars have Earth-like planets significantly improve the science yield of a mission to image exo-Earths?' In the case of the Occulting Ozone Observatory, a small external occulter mission that cannot measure spectra, we find that the occulter mission could confirm the orbits of ∼4 to ∼5 times as many exo-Earths if an astrometric mission preceded it to identify which stars had such planets. In the case of an

  13. One Novel Multiple-Target Plasmid Reference Molecule Targeting Eight Genetically Modified Canola Events for Genetically Modified Canola Detection.

    Science.gov (United States)

    Li, Zhuqing; Li, Xiang; Wang, Canhua; Song, Guiwen; Pi, Liqun; Zheng, Lan; Zhang, Dabing; Yang, Litao

    2017-09-27

    Multiple-target plasmid DNA reference materials have been generated and utilized as good substitutes of matrix-based reference materials in the analysis of genetically modified organisms (GMOs). Herein, we report the construction of one multiple-target plasmid reference molecule, pCAN, which harbors eight GM canola event-specific sequences (RF1, RF2, MS1, MS8, Topas 19/2, Oxy235, RT73, and T45) and a partial sequence of the canola endogenous reference gene PEP. The applicability of this plasmid reference material in qualitative and quantitative PCR assays of the eight GM canola events was evaluated, including the analysis of specificity, limit of detection (LOD), limit of quantification (LOQ), and performance of pCAN in the analysis of various canola samples, etc. The LODs are 15 copies for RF2, MS1, and RT73 assays using pCAN as the calibrator and 10 genome copies for the other events. The LOQ in each event-specific real-time PCR assay is 20 copies. In quantitative real-time PCR analysis, the PCR efficiencies of all event-specific and PEP assays are between 91% and 97%, and the squared regression coefficients (R 2 ) are all higher than 0.99. The quantification bias values varied from 0.47% to 20.68% with relative standard deviation (RSD) from 1.06% to 24.61% in the quantification of simulated samples. Furthermore, 10 practical canola samples sampled from imported shipments in the port of Shanghai, China, were analyzed employing pCAN as the calibrator, and the results were comparable with those assays using commercial certified materials as the calibrator. Concluding from these results, we believe that this newly developed pCAN plasmid is one good candidate for being a plasmid DNA reference material in the detection and quantification of the eight GM canola events in routine analysis.

  14. Update on Astrometric Follow-Up at Apache Point Observatory by Adler Planetarium

    Science.gov (United States)

    Nault, Kristie A.; Brucker, Melissa; Hammergren, Mark

    2016-10-01

    We began our NEO astrometric follow-up and characterization program in 2014 Q4 using about 500 hours of observing time per year with the Astrophysical Research Consortium (ARC) 3.5m telescope at Apache Point Observatory (APO). Our observing is split into 2 hour blocks approximately every other night for astrometry (this poster) and several half-nights per month for spectroscopy (see poster by M. Hammergren et al.) and light curve studies.For astrometry, we use the ARC Telescope Imaging Camera (ARCTIC) with an SDSS r filter, in 2 hour observing blocks centered around midnight. ARCTIC has a magnitude limit of V~23 in 60s, and we target 20 NEOs per session. ARCTIC has a FOV 1.57 times larger and a readout time half as long as the previous imager, SPIcam, which we used from 2014 Q4 through 2015 Q3. Targets are selected primarily from the Minor Planet Center's (MPC) NEO Confirmation Page (NEOCP), and NEA Observation Planning Aid; we also refer to JPL's What's Observable page, the Spaceguard Priority List and Faint NEOs List, and requests from other observers. To quickly adapt to changing weather and seeing conditions, we create faint, midrange, and bright target lists. Detected NEOs are measured with Astrometrica and internal software, and the astrometry is reported to the MPC.As of June 19, 2016, we have targeted 2264 NEOs, 1955 with provisional designations, 1582 of which were detected. We began observing NEOCP asteroids on January 30, 2016, and have targeted 309, 207 of which were detected. In addition, we serendipitously observed 281 moving objects, 201 of which were identified as previously known objects.This work is based on observations obtained with the Apache Point Observatory 3.5m telescope, which is owned and operated by the Astrophysical Research Consortium. We gratefully acknowledge support from NASA NEOO award NNX14AL17G and thank the University of Chicago Department of Astronomy and Astrophysics for observing time in 2014.

  15. Electrochemical Biosensors: A Solution to Pollution Detection with Reference to Environmental Contaminants

    Directory of Open Access Journals (Sweden)

    Gustavo Hernandez-Vargas

    2018-03-01

    Full Text Available The increasing environmental pollution with particular reference to emerging contaminants, toxic heavy elements, and other hazardous agents is a serious concern worldwide. Considering this global issue, there is an urgent need to design and develop strategic measuring techniques with higher efficacy and precision to detect a broader spectrum of numerous contaminants. The development of precise instruments can further help in real-time and in-process monitoring of the generation and release of environmental pollutants from different industrial sectors. Moreover, real-time monitoring can also reduce the excessive consumption of several harsh chemicals and reagents with an added advantage of on-site determination of contaminant composition prior to discharge into the environment. With key scientific advances, electrochemical biosensors have gained considerable attention to solve this problem. Electrochemical biosensors can be an excellent fit as an analytical tool for monitoring programs to implement legislation. Herein, we reviewed the current trends in the use of electrochemical biosensors as novel tools to detect various contaminant types including toxic heavy elements. A particular emphasis was given to screen-printed electrodes, nanowire sensors, and paper-based biosensors and their role in the pollution detection processes. Towards the end, the work is wrapped up with concluding remarks and future perspectives. In summary, electrochemical biosensors and related areas such as bioelectronics, and (bio-nanotechnology seem to be growing areas that will have a marked influence on the development of new bio-sensing strategies in future studies.

  16. Electrochemical Biosensors: A Solution to Pollution Detection with Reference to Environmental Contaminants.

    Science.gov (United States)

    Hernandez-Vargas, Gustavo; Sosa-Hernández, Juan Eduardo; Saldarriaga-Hernandez, Sara; Villalba-Rodríguez, Angel M; Parra-Saldivar, Roberto; Iqbal, Hafiz M N

    2018-03-24

    The increasing environmental pollution with particular reference to emerging contaminants, toxic heavy elements, and other hazardous agents is a serious concern worldwide. Considering this global issue, there is an urgent need to design and develop strategic measuring techniques with higher efficacy and precision to detect a broader spectrum of numerous contaminants. The development of precise instruments can further help in real-time and in-process monitoring of the generation and release of environmental pollutants from different industrial sectors. Moreover, real-time monitoring can also reduce the excessive consumption of several harsh chemicals and reagents with an added advantage of on-site determination of contaminant composition prior to discharge into the environment. With key scientific advances, electrochemical biosensors have gained considerable attention to solve this problem. Electrochemical biosensors can be an excellent fit as an analytical tool for monitoring programs to implement legislation. Herein, we reviewed the current trends in the use of electrochemical biosensors as novel tools to detect various contaminant types including toxic heavy elements. A particular emphasis was given to screen-printed electrodes, nanowire sensors, and paper-based biosensors and their role in the pollution detection processes. Towards the end, the work is wrapped up with concluding remarks and future perspectives. In summary, electrochemical biosensors and related areas such as bioelectronics, and (bio)-nanotechnology seem to be growing areas that will have a marked influence on the development of new bio-sensing strategies in future studies.

  17. Calculation of climatic reference values and its use for automatic outlier detection in meteorological datasets

    Directory of Open Access Journals (Sweden)

    B. Téllez

    2008-04-01

    Full Text Available The climatic reference values for monthly and annual average air temperature and total precipitation in Catalonia – northeast of Spain – are calculated using a combination of statistical methods and geostatistical techniques of interpolation. In order to estimate the uncertainty of the method, the initial dataset is split into two parts that are, respectively, used for estimation and validation. The resulting maps are then used in the automatic outlier detection in meteorological datasets.

  18. Detection of Salmonella enterica in Meat in Less than 5 Hours by a Low-Cost and Noncomplex Sample Preparation Method.

    Science.gov (United States)

    Fachmann, M S R; Löfström, C; Hoorfar, J; Hansen, F; Christensen, J; Mansdal, S; Josefsen, M H

    2017-03-01

    Salmonella is recognized as one of the most important foodborne bacteria and has wide health and socioeconomic impacts worldwide. Fresh pork meat is one of the main sources of Salmonella , and efficient and fast methods for detection are therefore necessary. Current methods for Salmonella detection in fresh meat usually include >16 h of culture enrichment, in a few cases IMPORTANCE While the cost of analysis and hands-on time of the presented rapid method were comparable to those of reference culture methods, the fast product release by this method can provide the meat industry with a competitive advantage. Not only will the abattoirs save costs for work hours and cold storage, but consumers and retailers will also benefit from fresher meat with a longer shelf life. Furthermore, the presented sample preparation might be adjusted for application in the detection of other pathogenic bacteria in different sample types. Copyright © 2017 American Society for Microbiology.

  19. Reference change values and power functions

    DEFF Research Database (Denmark)

    Iglesias Canadell, Natàlia; Hyltoft Petersen, Per; Jensen, Esther

    2004-01-01

    Repeated samplings and measurements in the monitoring of patients to look for changes are common clinical problems. The "reference change value", calculated as zp x [2 x (CVI2 + CVA2)](1/2), where zp is the z-statistic and CVI and CVA are within-subject and analytical coefficients of variation......, respectively, has been used to detect whether a measured difference between measurements is statistically significant. However, a reference change value only detects the probability of false-positives (type I error), and for this reason, a model to calculate the risk of missing significant changes in serial...... difference is the same as the calculated reference change value, then it will be detected in only 50% of situations....

  20. CoLiTec software - detection of the near-zero apparent motion

    Science.gov (United States)

    Khlamov, Sergii V.; Savanevych, Vadym E.; Briukhovetskyi, Olexandr B.; Pohorelov, Artem V.

    2017-06-01

    In this article we described CoLiTec software for full automated frames processing. CoLiTec software allows processing the Big Data of observation results as well as processing of data that is continuously formed during observation. The scope of solving tasks includes frames brightness equalization, moving objects detection, astrometry, photometry, etc. Along with the high efficiency of Big Data processing CoLiTec software also ensures high accuracy of data measurements. A comparative analysis of the functional characteristics and positional accuracy was performed between CoLiTec and Astrometrica software. The benefits of CoLiTec used with wide field and low quality frames were observed. The efficiency of the CoLiTec software was proved by about 700.000 observations and over 1.500 preliminary discoveries.

  1. Are Mindful Parents More Authoritative and Less Authoritarian? An Analysis of Clinic-Referred Mothers

    Science.gov (United States)

    Williams, Keith L.; Wahler, Robert G.

    2010-01-01

    Forty clinic-referred mothers completed questionnaires describing their children's problems, the mothers' parenting styles, and their everyday mindfulness. Psychometric analyses of the questionnaires showed mother reports to be internally consistent, except for one of the parenting style scales (i.e., permissive style). We dropped the scale and…

  2. Reference-free fatigue crack detection using nonlinear ultrasonic modulation under various temperature and loading conditions

    Science.gov (United States)

    Lim, Hyung Jin; Sohn, Hoon; DeSimio, Martin P.; Brown, Kevin

    2014-04-01

    This study presents a reference-free fatigue crack detection technique using nonlinear ultrasonic modulation. When low frequency (LF) and high frequency (HF) inputs generated by two surface-mounted lead zirconate titanate (PZT) transducers are applied to a structure, the presence of a fatigue crack can provide a mechanism for nonlinear ultrasonic modulation and create spectral sidebands around the frequency of the HF signal. The crack-induced spectral sidebands are isolated using a combination of linear response subtraction (LRS), synchronous demodulation (SD) and continuous wavelet transform (CWT) filtering. Then, a sequential outlier analysis is performed on the extracted sidebands to identify the crack presence without referring any baseline data obtained from the intact condition of the structure. Finally, the robustness of the proposed technique is demonstrated using actual test data obtained from simple aluminum plate and complex aircraft fitting-lug specimens under varying temperature and loading variations.

  3. Pain detection by clinical questionnaire in patients referred for temporomandibular disorders in a Chilean hospital.

    Directory of Open Access Journals (Sweden)

    Tomás Maturana

    2015-10-01

    Full Text Available Aim: To determine pain frequency by means of a clinical screening questionnaire in patients with temporomandibular disorders (TMD referred to the general Hospital of Valdivia (HBV between September and December 2014. Material and method: A descriptive study, which included patients referred to the TMD Unit of the dental service at HBV between September and December 2014, was carried out. A clinical screening questionnaire was applied by an examiner in order to detect painful Temporomandibular Joint Disorders. The variables age, sex, wait time, and presence of related TMD pain were measured. Results: 101 patients were surveyed; 88.17% (84 patients were women. Average age was 33.5 (11-70 years; 66% of patients had mandibular pain or stiffness upon awakening; 80% informed pain related to painful TMD. Conclusion: Most surveyed patients were women. Pain was highly frequent in the surveyed population; its main location was in temporal areas.

  4. Biochemical evaluation in human saliva with special reference to ovulation detection

    Directory of Open Access Journals (Sweden)

    Alagendran S

    2010-01-01

    Full Text Available Aim : The aim of the present study was to investigate the level of salivary sialic acids and glycosaminoglycans with reference to salivary hormones during the normal menstrual cycle. Settings and Design: Fifty women volunteers were selected for the present study. Materials and Methods : Saliva was collected from 50 women and ovulation was detected in women with normal menstrual cycles through basal body temperature (BBT, ultrasound and salivary ferning. Samples were divided into five categories, as prepubertal (6-9 years, pre-ovulatory phase (6-12 days, ovulatory phase (13-14 days, postovulatory phase (15-26 days and menopause (above 45 years. Each sample was subjected to evaluation of the sialic acids and glycosaminoglycans along with salivary hormones. Results : The result revealed that the ovulatory phase has increased sialic acid and glycosaminoglycans during the menstrual cycle when compared with that of the other phases. Consequently, an increased level of hormones such as luteinizing hormone and estrogen during the ovulatory period when compared to that of the pre-ovulatory and postovulatory periods appeared to be noteworthy. Statistically, analysis was performed using one way-ANOVA (LSD; post hoc method to determine the significance as P < 0.001, 0.01, 0.05 in between the reproductive phases of the menstrual cycle. Conclusion : This study concluded that saliva-specific carbohydrates in the ovulatory saliva make the possibility to develop a biomarker for detection of ovulation by non-invasive methods.

  5. Reference free phasing and representation of complex variation

    DEFF Research Database (Denmark)

    Jensen, Jacob Malte

    2017-01-01

    High throughput sequencing has revolutionized our ability to interrogate genomes and entire human genomes are sequenced daily across the world. Mapping of short reads to a reference genome has enhanced our ability to detect genetic variation and is currently the most widely used technology....... Therefore, new methods for detecting variation that reduce reference bias are needed including ways of representing genomes that account for the variability within and between populations. The major histocompatibility complex (MHC) region is one of the most diverse and complex regions of the human genome...... to detect and call variation in humans. However, it has become evident that mapping of short reads to a single reference genome is subject to ascertainment bias (reference bias). This bias is especially pronounced in complex regions of the genome and particularly hampers detection of structural variation...

  6. Event-specific qualitative and quantitative detection of five genetically modified rice events using a single standard reference molecule.

    Science.gov (United States)

    Kim, Jae-Hwan; Park, Saet-Byul; Roh, Hyo-Jeong; Shin, Min-Ki; Moon, Gui-Im; Hong, Jin-Hwan; Kim, Hae-Yeong

    2017-07-01

    One novel standard reference plasmid, namely pUC-RICE5, was constructed as a positive control and calibrator for event-specific qualitative and quantitative detection of genetically modified (GM) rice (Bt63, Kemingdao1, Kefeng6, Kefeng8, and LLRice62). pUC-RICE5 contained fragments of a rice-specific endogenous reference gene (sucrose phosphate synthase) as well as the five GM rice events. An existing qualitative PCR assay approach was modified using pUC-RICE5 to create a quantitative method with limits of detection correlating to approximately 1-10 copies of rice haploid genomes. In this quantitative PCR assay, the square regression coefficients ranged from 0.993 to 1.000. The standard deviation and relative standard deviation values for repeatability ranged from 0.02 to 0.22 and 0.10% to 0.67%, respectively. The Ministry of Food and Drug Safety (Korea) validated the method and the results suggest it could be used routinely to identify five GM rice events. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. With Reference to Reference Genes: A Systematic Review of Endogenous Controls in Gene Expression Studies.

    Science.gov (United States)

    Chapman, Joanne R; Waldenström, Jonas

    2015-01-01

    The choice of reference genes that are stably expressed amongst treatment groups is a crucial step in real-time quantitative PCR gene expression studies. Recent guidelines have specified that a minimum of two validated reference genes should be used for normalisation. However, a quantitative review of the literature showed that the average number of reference genes used across all studies was 1.2. Thus, the vast majority of studies continue to use a single gene, with β-actin (ACTB) and/or glyceraldehyde 3-phosphate dehydrogenase (GAPDH) being commonly selected in studies of vertebrate gene expression. Few studies (15%) tested a panel of potential reference genes for stability of expression before using them to normalise data. Amongst studies specifically testing reference gene stability, few found ACTB or GAPDH to be optimal, whereby these genes were significantly less likely to be chosen when larger panels of potential reference genes were screened. Fewer reference genes were tested for stability in non-model organisms, presumably owing to a dearth of available primers in less well characterised species. Furthermore, the experimental conditions under which real-time quantitative PCR analyses were conducted had a large influence on the choice of reference genes, whereby different studies of rat brain tissue showed different reference genes to be the most stable. These results highlight the importance of validating the choice of normalising reference genes before conducting gene expression studies.

  8. Certified reference materials and reference methods for nuclear safeguards and security.

    Science.gov (United States)

    Jakopič, R; Sturm, M; Kraiem, M; Richter, S; Aregbe, Y

    2013-11-01

    Confidence in comparability and reliability of measurement results in nuclear material and environmental sample analysis are established via certified reference materials (CRMs), reference measurements, and inter-laboratory comparisons (ILCs). Increased needs for quality control tools in proliferation resistance, environmental sample analysis, development of measurement capabilities over the years and progress in modern analytical techniques are the main reasons for the development of new reference materials and reference methods for nuclear safeguards and security. The Institute for Reference Materials and Measurements (IRMM) prepares and certifices large quantities of the so-called "large-sized dried" (LSD) spikes for accurate measurement of the uranium and plutonium content in dissolved nuclear fuel solutions by isotope dilution mass spectrometry (IDMS) and also develops particle reference materials applied for the detection of nuclear signatures in environmental samples. IRMM is currently replacing some of its exhausted stocks of CRMs with new ones whose specifications are up-to-date and tailored for the demands of modern analytical techniques. Some of the existing materials will be re-measured to improve the uncertainties associated with their certified values, and to enable laboratories to reduce their combined measurement uncertainty. Safeguards involve the quantitative verification by independent measurements so that no nuclear material is diverted from its intended peaceful use. Safeguards authorities pay particular attention to plutonium and the uranium isotope (235)U, indicating the so-called 'enrichment', in nuclear material and in environmental samples. In addition to the verification of the major ratios, n((235)U)/n((238)U) and n((240)Pu)/n((239)Pu), the minor ratios of the less abundant uranium and plutonium isotopes contain valuable information about the origin and the 'history' of material used for commercial or possibly clandestine purposes, and

  9. Micro-arcsecond Celestial Reference Frames: definition and realization — Impact of the recent IAU Resolutions

    International Nuclear Information System (INIS)

    Capitaine, Nicole

    2012-01-01

    improvements in the fields of astrometry, celestial mechanics, geodynamics, geodesy, etc. Of special interest are the improvements in the model for variations in Earth's rotation, which, in turn, can provide better knowledge of the dynamics of the Earth's interior. These have also contributed to a significant improvement in the accuracy of the ephemerides of the solar system bodies as determined from modern measurements, with a large number of scientific applications. This paper recalls the main aspects of the recent IAU resolutions on reference systems as well as their consequences on the concepts, definitions, nomenclature and models that are suitable for the definition, realization and transformation of reference frames at a microarcsecond level.

  10. Stuttering Thoughts: Negative Self-Referent Thinking Is Less Sensitive to Aversive Outcomes in People with Higher Levels of Depressive Symptoms.

    Science.gov (United States)

    Iijima, Yudai; Takano, Keisuke; Boddez, Yannick; Raes, Filip; Tanno, Yoshihiko

    2017-01-01

    Learning theories of depression have proposed that depressive cognitions, such as negative thoughts with reference to oneself, can develop through a reinforcement learning mechanism. This negative self-reference is considered to be positively reinforced by rewarding experiences such as genuine support from others after negative self-disclosure, and negatively reinforced by avoidance of potential aversive situations. The learning account additionally predicts that negative self-reference would be maintained by an inability to adjust one's behavior when negative self-reference no longer leads to such reward. To test this prediction, we designed an adapted version of the reversal-learning task. In this task, participants were reinforced to choose and engage in either negative or positive self-reference by probabilistic economic reward and punishment. Although participants were initially trained to choose negative self-reference, the stimulus-reward contingencies were reversed to prompt a shift toward positive self-reference (Study 1) and a further shift toward negative self-reference (Study 2). Model-based computational analyses showed that depressive symptoms were associated with a low learning rate of negative self-reference, indicating a high level of reward expectancy for negative self-reference even after the contingency reversal. Furthermore, the difficulty in updating outcome predictions of negative self-reference was significantly associated with the extent to which one possesses negative self-images. These results suggest that difficulty in adjusting action-outcome estimates for negative self-reference increases the chance to be faced with negative aspects of self, which may result in depressive symptoms.

  11. Stuttering Thoughts: Negative Self-Referent Thinking Is Less Sensitive to Aversive Outcomes in People with Higher Levels of Depressive Symptoms

    Directory of Open Access Journals (Sweden)

    Yudai Iijima

    2017-08-01

    Full Text Available Learning theories of depression have proposed that depressive cognitions, such as negative thoughts with reference to oneself, can develop through a reinforcement learning mechanism. This negative self-reference is considered to be positively reinforced by rewarding experiences such as genuine support from others after negative self-disclosure, and negatively reinforced by avoidance of potential aversive situations. The learning account additionally predicts that negative self-reference would be maintained by an inability to adjust one’s behavior when negative self-reference no longer leads to such reward. To test this prediction, we designed an adapted version of the reversal-learning task. In this task, participants were reinforced to choose and engage in either negative or positive self-reference by probabilistic economic reward and punishment. Although participants were initially trained to choose negative self-reference, the stimulus-reward contingencies were reversed to prompt a shift toward positive self-reference (Study 1 and a further shift toward negative self-reference (Study 2. Model-based computational analyses showed that depressive symptoms were associated with a low learning rate of negative self-reference, indicating a high level of reward expectancy for negative self-reference even after the contingency reversal. Furthermore, the difficulty in updating outcome predictions of negative self-reference was significantly associated with the extent to which one possesses negative self-images. These results suggest that difficulty in adjusting action-outcome estimates for negative self-reference increases the chance to be faced with negative aspects of self, which may result in depressive symptoms.

  12. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference

    International Nuclear Information System (INIS)

    Yamada, Yoshitake; Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Kuribayashi, Sachio; Abe, Takayuki; Ogawa, Kenji

    2013-01-01

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA -950 ) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P -950 . The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA -950 . (orig.)

  13. Enzyme-less electrochemical displacement heterogeneous immunosensor for diclofenac detection.

    Science.gov (United States)

    Nguyen, T T K; Vu, T T; Anquetin, G; Tran, H V; Reisberg, S; Noël, V; Mattana, G; Nguyen, Q V; Dai Lam, Tran; Pham, M C; Piro, B

    2017-11-15

    We describe an electrochemical immunosensor based on functionalization of a working electrode by electrografting two functional diazonium salts. The first one is a molecular probe, diclofenac, coupled with an arylamine onto which a specific antibody is immobilized by affinity interactions; the second is a redox probe (a quinone) also coupled with an arylamine, able to transduce the hapten-antibody association into a change in electroactivity. The steric hindrance induced by the antibody leads to a current decrease upon binding of the antibody on the grafted molecular probe; conversely, when diclofenac is present in solution, a displacement equilibrium occurs between the target diffusing into the solution and the grafted probe. This leads to dissociation of the antibody from the electrode surface, event which is transduced into a current increase ("signal-on" detection). The detection limit is ca. 20 fM, corresponding to 6pgL -1 diclofenac, which is competitive compared to other label-free immunosensors. We demonstrate that the sensor is selective and is able to quantify diclofenac in tap water. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Early detection of lung function decrements in children and adolescents with cystic fibrosis using new reference values.

    Science.gov (United States)

    Zacharasiewicz, Angela; Renner, Sabine; Haderer, Flora; Weber, Michael; Dehlink, Eleonore; Szepfalusi, Zsolt; Frischer, Thomas

    2017-08-01

    Interpretation of lung function values in children with cystic fibrosis (CF) depends on the applied reference values. We hypothesize that differences between the new global lung function initiative (GLI) values and the formerly used Zapletal et al. values produce significantly different clinical results. We analyzed 3719 lung function measurements of 108 children and adolescents (n = 54 male; aged 6-18 years) with CF treated between September 1991 and July 2009. Data were analyzed in milliliters (ml) and % predicted (pred.) and interpreted using Zapletal and GLI reference values. Applying GLI compared to Zapletal resulted in significantly lower mean forced expiratory volume in 1s (FEV1)% pred. Zapletal 86.6% (SD 20.6), GLI 79.9% (SD 20.3) and 32% (n = 497/1543) were misclassified as normal when using Zapletal. Despite showing no overall differences in FEV1 and forced vital capacity (FVC) between concomitant Pseudomonas detection (PA+) in n = 938 and Pseudomonas negative (PA-) (n = 2781) using either reference PA+ resulted in lower FEV1 and FVC values with increasing age; however, measurement of small airway obstruction with forced expiratory flow at 75% of FVC (FEF75) values - available for Zapletal -showed significant differences. Reassurance regarding lung function when using old reference values may occur with potential clinical significance. Discrepancies in lung function interpretation underline the importance of using uniform and best available reference values.

  15. Capacitive Sensing for Contact-less Proximity Detection in Industrial Marble Machines

    Directory of Open Access Journals (Sweden)

    Sergio Saponara

    2010-02-01

    Full Text Available The paper presents the design and experimental characterization of capacitive sensors, plus the relevant front-end acquisition circuitry, for process control in industrial marble machines. The new developed sensing system allows detecting, in real-time and without any contact, the presence of stone samples under the abrasive/cutting heads in an industrial machine. The obtained detection signal is needed as a feedback to improve the automatic control of the polishing/cutting process in marble industry. Different types of sensors are proposed whose performances are assessed through experimental test campaigns considering real industrial working conditions. Compared to state-of-art sensors the proposed solutions allow for a reliable detection while being of low complexity and robust to harsh environment conditions.

  16. Reference geometry-based detection of (4D-)CT motion artifacts: a feasibility study

    Science.gov (United States)

    Werner, René; Gauer, Tobias

    2015-03-01

    Respiration-correlated computed tomography (4D or 3D+t CT) can be considered as standard of care in radiation therapy treatment planning for lung and liver lesions. The decision about an application of motion management devices and the estimation of patient-specific motion effects on the dose distribution relies on precise motion assessment in the planning 4D CT data { which is impeded in case of CT motion artifacts. The development of image-based/post-processing approaches to reduce motion artifacts would benefit from precise detection and localization of the artifacts. Simple slice-by-slice comparison of intensity values and threshold-based analysis of related metrics suffer from- depending on the threshold- high false-positive or -negative rates. In this work, we propose exploiting prior knowledge about `ideal' (= artifact free) reference geometries to stabilize metric-based artifact detection by transferring (multi-)atlas-based concepts to this specific task. Two variants are introduced and evaluated: (S1) analysis and comparison of warped atlas data obtained by repeated non-linear atlas-to-patient registration with different levels of regularization; (S2) direct analysis of vector field properties (divergence, curl magnitude) of the atlas-to-patient transformation. Feasibility of approaches (S1) and (S2) is evaluated by motion-phantom data and intra-subject experiments (four patients) as well as - adopting a multi-atlas strategy- inter-subject investigations (twelve patients involved). It is demonstrated that especially sorting/double structure artifacts can be precisely detected and localized by (S1). In contrast, (S2) suffers from high false positive rates.

  17. Molecular detection of the carriers of Staphylococcus aureus golden in referred to the Imam Ali Clinic in Shahrekord, Iran

    Directory of Open Access Journals (Sweden)

    Maryam Reisi

    2014-12-01

    Full Text Available Objective: To conduct for the molecular detection of Staphylococcus aureus (S. aureus (Golden staph carriers among patients referred to the Imam Ali Clinic, Shahrekord, Iran. Methods: This sectional-descriptive study was conducted with 200 persons with suspected upper respiratory tract infections, who were referred to the Imam Ali Clinic in Shahrekord, Iran, in 2012. After culturing the nasal swab samples in mannitol salt agar and blood agar, S. aureus colonies were confirmed by biochemical methods. To determine the susceptibility of S. aureus strains isolated, molecular methods were used. Results: Among the 200 investigated samples, 60 cases (30%, comprising 25 men (41.66% and 35 women (58.33%, were found to be S. aureus carriers. Conclusions: The results of the present study showed that the frequency of the S. aureus strain isolated from the nasal swabs of patients with respiratory tract infections admitted to the Imam Ali Clinic in Shahrekord, Iran, was remarkable. Thus, knowing detection of S. aureus carriers, who are at a risk of spreading nosocomial infection among the staff, is vital to control and prevent nosocomial infections.

  18. Laparoendoscopic single site (LESS) cholecystectomy.

    Science.gov (United States)

    Hodgett, Steven E; Hernandez, Jonathan M; Morton, Connor A; Ross, Sharona B; Albrink, Michael; Rosemurgy, Alexander S

    2009-02-01

    The journey from conventional "open" operations to truly "minimally invasive" operations naturally includes progression from operations involving multiple trocars and multiple incisions to operations involving access through the umbilicus alone. Laparoscopic operations through the umbilicus alone, laparoendoscopic single site surgery (LESS), offer improved cosmesis and hopes for less pain and improved recovery. This study was undertaken to evaluate our initial experience with LESS cholecystectomy and to compare our initial experience to concurrent outcomes with more conventional multiport, multi-incision laparoscopic cholecystectomy. All patients referred for cholecystectomy over a 6-month period were offered LESS. Outcomes, including blood loss, operative time, complications, and length of stay were recorded. Outcomes with our first LESS cholecystectomies were compared to an uncontrolled group of concurrent patients undergoing multiport, multi-incision laparoscopic cholecystectomy at the same hospital by the same surgeon. Twenty-nine patients of median age 50 years undergoing LESS cholecystectomy from November 2007 until May 2008 were compared to 29* patients, median age 48 years, undergoing standard multiport, multiple-incision laparoscopic cholecystectomy over the same time period. Median operative time for patients undergoing LESS cholecystectomy was 72 min and was not different from that of patients undergoing multiport, multi-incision laparoscopic cholecystectomy (p = 0.81). Median length of hospital stay was 1.0 day for patients undergoing LESS cholecystectomy and was not different from patients undergoing standard laparoscopic cholecystectomy (p = 0.46). Operative estimated blood loss was less than 100 cc for all patients. No patients undergoing attempted LESS cholecystectomy had conversions to "open" operations; two patients had an additional trocar(s) placed distant from the umbilicus to aid in exposure. Three patients undergoing LESS cholecystectomy had

  19. International VLBI Service for Geodesy and Astrometry. Delivering high-quality products and embarking on observations of the next generation

    Science.gov (United States)

    Nothnagel, A.; Artz, T.; Behrend, D.; Malkin, Z.

    2017-07-01

    The International VLBI Service for Geodesy and Astrometry (IVS) regularly produces high-quality Earth orientation parameters from observing sessions employing extensive networks or individual baselines. The master schedule is designed according to the telescope days committed by the stations and by the need for dense sampling of the Earth orientation parameters (EOP). In the pre-2011 era, the network constellations with their number of telescopes participating were limited by the playback and baseline capabilities of the hardware (Mark4) correlators. This limitation was overcome by the advent of software correlators, which can now accommodate many more playback units in a flexible configuration. In this paper, we describe the current operations of the IVS with special emphasis on the quality of the polar motion results since these are the only EOP components which can be validated against independent benchmarks. The polar motion results provided by the IVS have improved continuously over the years, now providing an agreement with IGS results at the level of 20-25 μas in a WRMS sense. At the end of the paper, an outlook is given for the realization of the VLBI Global Observing System.

  20. Development of references of anomalies detection on P91 material using Self-Magnetic Leakage Field (SMLF) technique

    Science.gov (United States)

    Husin, Shuib; Afiq Pauzi, Ahmad; Yunus, Salmi Mohd; Ghafar, Mohd Hafiz Abdul; Adilin Sekari, Saiful

    2017-10-01

    This technical paper demonstrates the successful of the application of self-magnetic leakage field (SMLF) technique in detecting anomalies in weldment of a thick P91 materials joint (1 inch thickness). Boiler components such as boiler tubes, stub boiler at penthouse and energy piping such as hot reheat pipe (HRP) and H-balance energy piping to turbine are made of P91 material. P91 is ferromagnetic material, therefore the technique of self-magnetic leakage field (SMLF) is applicable for P91 in detecting anomalies within material (internal defects). The technique is categorized under non-destructive technique (NDT). It is the second passive method after acoustic emission (AE), at which the information on structures radiation (magnetic field and energy waves) is used. The measured magnetic leakage field of a product or component is a magnetic leakage field occurring on the component’s surface in the zone of dislocation stable slipbands under the influence of operational (in-service) or residual stresses or in zones of maximum inhomogeneity of metal structure in new products or components. Inter-granular and trans-granular cracks, inclusion, void, cavity and corrosion are considered types of inhomogeneity and discontinuity in material where obviously the output of magnetic leakage field will be shown when using this technique. The technique does not required surface preparation for the component to be inspected. This technique is contact-type inspection, which means the sensor has to touch or in-contact to the component’s surface during inspection. The results of application of SMLF technique on the developed P91 reference blocks have demonstrated that the technique is practical to be used for anomaly inspection and detection as well as identification of anomalies’ location. The evaluation of this passive self-magnetic leakage field (SMLF) technique has been verified by other conventional non-destructive tests (NDTs) on the reference blocks where simulated

  1. Detection of Salmonella enterica in meat in less than 5 hours by a low-cost and non-complex sample preparation method

    DEFF Research Database (Denmark)

    Fachmann, Mette Sofie Rousing; Löfström, Charlotta; Hoorfar, Jeffrey

    2017-01-01

    peptone water, and a real-time PCR compatible sample preparation method, based on filtration, centrifugation, and enzymatic digestion, followed by fast cycling real-time PCR detection. The method was validated in an un-paired, comparative study against the Nordic Committee on Food Analysis (NMKL......, and help contribute to improved food safety. While the cost of analysis and hands-on time of the presented rapid method were comparable to reference culture methods, the fast product release by this method can provide the meat industry with a competitive advantage. Not only will the abattoirs save costs......Salmonella is recognised as one of the most important foodborne bacteria, and has a wide health and socioeconomical impact worldwide. Fresh pork meat is one of the main sources of Salmonella and efficient and fast methods for detection are therefore necessary. Current methods for Salmonella...

  2. Characteristics and screening outcome of women referred twice at screening mammography

    International Nuclear Information System (INIS)

    Setz-Pels, Wikke; Duijm, Lucien E.M.; Jansen, Frits H.; Louwman, Marieke W.J.; Roumen, Rudi M.H.; Voogd, Adri C.

    2012-01-01

    To determine the characteristics and screening outcome of women referred twice at screening mammography. We included 424,703 consecutive screening mammograms and collected imaging, biopsy and surgery reports of women with screen-detected breast cancer. Review of screening mammograms was performed to determine whether or not an initial and second referral comprised the same lesion. The overall positive predictive value of referral for cancer was 38.6% (95% CI 37.3-39.8%). Of 147 (2.6%) women referred twice, 86 had been referred for a different lesion at second referral and 32 of these proved malignant (37.2%, 95% CI 27.0-47.4%). Sixty-one women had been referred twice for the same lesion, of which 22 proved malignant (36.1%, 95% CI 24.1-48.0%). Characteristics of these women were comparable to women with cancer diagnosed after first referral. Compared with women without cancer at second referral for the same lesion, women with cancer more frequently showed suspicious densities at screening mammography (86.4% vs 53.8%, P = 0.02) and work-up at first referral had less frequently included biopsy (22.7% vs 61.5%, P = 0.004). Cancer risk in women referred twice for the same lesion is similar to that observed in women referred once, or referred for a second time but for a different lesion. (orig.)

  3. Frame-less and mask-less cranial stereotactic radiosurgery: a feasibility study

    International Nuclear Information System (INIS)

    Cervino, Laura I; Pawlicki, Todd; Lawson, Joshua D; Jiang, Steve B

    2010-01-01

    Currently, high-precision delivery in stereotactic radiosurgery (SRS) is achieved via high-precision target localization and rigid patient immobilization. Rigid patient immobilization can result in, however, patient discomfort, which is exacerbated by the long duration of SRS treatments and may induce patient movement. To address this issue, we developed a new SRS technique that is aimed to minimize patient discomfort while maintaining high-precision treatment, based on a less-rigid patient immobilization combined with continuous patient motion monitoring. In this paper, we examine the feasibility of this new technique. An anthropomorphic head phantom is used to check the accuracy of a 3D surface imaging system that provides the monitoring. Volunteers are used to study patient motion inside a new type of head mold that is used for minimal immobilization. Results show that for different couch angles, the difference between the phantom positions recorded by the surface imaging system and by an infrared optical tracking system was within 1 mm in displacements and 1 deg. in rotation. The motion detected by both systems during couch shifts is within 1 mm agreement. The average maximum volunteer head motion in the head mold during the 20 min interval in any direction was 0.7 mm (range: 0.4-1.1 mm). Patient motion due to couch motion was always less than 0.2 mm. We conclude that motion inside the minimally immobilizing head mold is small and can be accurately detected by real-time surface imaging.

  4. Frame-less and mask-less cranial stereotactic radiosurgery: a feasibility study

    Science.gov (United States)

    Cerviño, Laura I.; Pawlicki, Todd; Lawson, Joshua D.; Jiang, Steve B.

    2010-04-01

    Currently, high-precision delivery in stereotactic radiosurgery (SRS) is achieved via high-precision target localization and rigid patient immobilization. Rigid patient immobilization can result in, however, patient discomfort, which is exacerbated by the long duration of SRS treatments and may induce patient movement. To address this issue, we developed a new SRS technique that is aimed to minimize patient discomfort while maintaining high-precision treatment, based on a less-rigid patient immobilization combined with continuous patient motion monitoring. In this paper, we examine the feasibility of this new technique. An anthropomorphic head phantom is used to check the accuracy of a 3D surface imaging system that provides the monitoring. Volunteers are used to study patient motion inside a new type of head mold that is used for minimal immobilization. Results show that for different couch angles, the difference between the phantom positions recorded by the surface imaging system and by an infrared optical tracking system was within 1 mm in displacements and 1° in rotation. The motion detected by both systems during couch shifts is within 1 mm agreement. The average maximum volunteer head motion in the head mold during the 20 min interval in any direction was 0.7 mm (range: 0.4-1.1 mm). Patient motion due to couch motion was always less than 0.2 mm. We conclude that motion inside the minimally immobilizing head mold is small and can be accurately detected by real-time surface imaging.

  5. ANTIBIOTICS IN THE ENVIRONMENTS; LESS RECOGNIZED ...

    Science.gov (United States)

    There is no abstract available for this product. If further information is requested, please refer to the bibliographic citation and contact the person listed under Contact field. The research focused on in the subtasks is the development and application of state-of the-art technologies to meet the needs of the public, Office of Water, and ORD in the area of Water Quality. Located In the subtasks are the various research projects being performed in support of this Task and more in-depth coverage of each project. Briefly, each project's objective is stated below.Subtask 1: To integrate state-of-the-art technologies (polar organic chemical integrative samplers, advanced solid-phase extraction methodologies with liquid chromatography/electrospray/mass spectrometry) and apply them to studying the sources and fate of a select list of PPCPs. Application and improvement of analytical methodologies that can detect non-volatile, polar, water-soluble pharmaceuticals in source waters at levels that could be environmentally significant (at concentrations less than parts per billion, ppb). IAG with USGS ends in FY05. APM 20 due in FY05.Subtask 2: Coordination of interagency research and public outreach activities for PPCPs. Participate on NSTC Health and Environment subcommittee working group on PPCPs. Web site maintenance and expansion, invited technical presentations, invited articles for peer-reviewed journals, interviews for media, responding to public inquiries. S

  6. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Yoshitake [Keio University School of Medicine, Department of Diagnostic Radiology, Tokyo (Japan); Nippon Koukan Hospital, Department of Radiology, Kawasaki-shi, Kanagawa (Japan); Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Kuribayashi, Sachio [Keio University School of Medicine, Department of Diagnostic Radiology, Tokyo (Japan); Abe, Takayuki [Keio University School of Medicine, Center for Clinical Research, Tokyo (Japan); Ogawa, Kenji [Nippon Koukan Hospital, Department of Radiology, Kawasaki-shi, Kanagawa (Japan)

    2013-08-15

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA{sub -950}) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P < 0.0001) of tomosynthesis than radiography for the detection of pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA{sub -950}. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA{sub -950}. (orig.)

  7. Astrophysical techniques

    CERN Document Server

    Kitchin, CR

    2013-01-01

    DetectorsOptical DetectionRadio and Microwave DetectionX-Ray and Gamma-Ray DetectionCosmic Ray DetectorsNeutrino DetectorsGravitational Radiation Dark Matter and Dark Energy Detection ImagingThe Inverse ProblemPhotographyElectronic ImagingScanningInterferometrySpeckle InterferometryOccultationsRadarElectronic ImagesPhotometryPhotometryPhotometersSpectroscopySpectroscopy SpectroscopesOther TechniquesAstrometryPolarimetrySolar StudiesMagnetometryComputers and The Internet.

  8. Electrochemical Determination of the Antioxidant Potential of Some Less Common Fruit Species

    Directory of Open Access Journals (Sweden)

    Boris Krska

    2008-11-01

    Full Text Available Various berries and fruit types of less common fruit species are known to contain antioxidants. Consumption of high amounts of antioxidant flavonoids, which display a variety of biological properties, including antiproliferative and anti-inflammatory activity, may have a positive impact on human health, particularly for the prevention of cancer and other inflammatory diseases. In these studies, based on the hypothesis that the fruit extract with the highest content would possess significantly higher health benefits, flavonoid-rich extracts were obtained from some less common fruit species – Blue Honeysuckles (Lonicera Kamtschatica and Lonicera edulis, Turcz. ex. Freyn, Saskatoon berry (Amelanchier alnifolia Nutt. and Chinese Hawthorn (Crataegus pinnatifida BUNGE – grown from germplasm held at the Mendel University of Agriculture and Forestry in Brno, Czech Republic and then characterized in terms of biological value based on the results from a relative antioxidant capacity assessment. The antioxidant content evaluation was based on the total flavonoid amount, determined by liquid chromatography with electrochemical detection (HPLC-ED. A DPPH• test was applied as a reference. The antioxidant content measured in Chinese Hawthorn fruit extract identified it as a potent source of flavonoid antioxidants, with a content 9-fold higher than that seen in Amelanchier fruit. The multifunctional HPLC-ED array method coupled with a DPPH• reference appears to be the optimal analytical progress, accurately reflecting the nutritivetherapeutic properties of a fruit.

  9. Using Gaia as an Astrometric Tool for Deep Ground-based Surveys

    Science.gov (United States)

    Casetti-Dinescu, Dana I.; Girard, Terrence M.; Schriefer, Michael

    2018-04-01

    Gaia DR1 positions are used to astrometrically calibrate three epochs' worth of Subaru SuprimeCam images in the fields of globular cluster NGC 2419 and the Sextans dwarf spheroidal galaxy. Distortion-correction ``maps'' are constructed from a combination of offset dithers and reference to Gaia DR1. These are used to derive absolute proper motions in the field of NGC 2419. Notably, we identify the photometrically-detected Monoceros structure in the foreground of NGC 2419 as a kinematically-cold population of stars, distinct from Galactic-field stars. This project demonstrates the feasibility of combining Gaia with deep, ground-based surveys, thus extending high-quality astrometry to magnitudes beyond the limits of Gaia.

  10. Human papillomavirus detection with genotyping by the cobas and Aptima assays: Significant differences in HPV 16 detection?

    Science.gov (United States)

    Chorny, Joseph A; Frye, Teresa C; Fisher, Beth L; Remmers, Carol L

    2018-03-23

    The primary high-risk human papillomavirus (hrHPV) assays in the United States are the cobas (Roche) and the Aptima (Hologic). The cobas assay detects hrHPV by DNA analysis while the Aptima detects messenger RNA (mRNA) oncogenic transcripts. As the Aptima assay identifies oncogenic expression, it should have a lower rate of hrHPV and genotype detection. The Kaiser Permanente Regional Reference Laboratory in Denver, Colorado changed its hrHPV assay from the cobas to the Aptima assay. The rates of hrHPV detection and genotyping were compared over successive six-month periods. The overall hrHPV detection rates by the two platforms were similar (9.5% versus 9.1%) and not statistically different. For genotyping, the HPV 16 rate by the cobas was 1.6% and by the Aptima it was 1.1%. These differences were statistically different with the Aptima detecting nearly one-third less HPV 16 infections. With the HPV 18 and HPV 18/45, there was a slightly higher detection rate of HPV 18/45 by the Aptima platform (0.5% versus 0.9%) and this was statistically significant. While HPV 16 represents a low percentage of hrHPV infections, it was detected significantly less by the Aptima assay compared to the cobas assay. This has been previously reported, although not highlighted. Given the test methodologies, one would expect the Aptima to detect less HPV 16. This difference appears to be mainly due to a significantly increased number of non-oncogenic HPV 16 infections detected by the cobas test as there were no differences in HPV 16 detection rates in the high-grade squamous intraepithelial lesions indicating that the two tests have similar sensitivities for oncogenic HPV 16. © 2018 Wiley Periodicals, Inc.

  11. Evaluation of four endogenous reference genes and their real-time PCR assays for common wheat quantification in GMOs detection.

    Science.gov (United States)

    Huang, Huali; Cheng, Fang; Wang, Ruoan; Zhang, Dabing; Yang, Litao

    2013-01-01

    Proper selection of endogenous reference genes and their real-time PCR assays is quite important in genetically modified organisms (GMOs) detection. To find a suitable endogenous reference gene and its real-time PCR assay for common wheat (Triticum aestivum L.) DNA content or copy number quantification, four previously reported wheat endogenous reference genes and their real-time PCR assays were comprehensively evaluated for the target gene sequence variation and their real-time PCR performance among 37 common wheat lines. Three SNPs were observed in the PKABA1 and ALMT1 genes, and these SNPs significantly decreased the efficiency of real-time PCR amplification. GeNorm analysis of the real-time PCR performance of each gene among common wheat lines showed that the Waxy-D1 assay had the lowest M values with the best stability among all tested lines. All results indicated that the Waxy-D1 gene and its real-time PCR assay were most suitable to be used as an endogenous reference gene for common wheat DNA content quantification. The validated Waxy-D1 gene assay will be useful in establishing accurate and creditable qualitative and quantitative PCR analysis of GM wheat.

  12. Evaluation of four endogenous reference genes and their real-time PCR assays for common wheat quantification in GMOs detection.

    Directory of Open Access Journals (Sweden)

    Huali Huang

    Full Text Available Proper selection of endogenous reference genes and their real-time PCR assays is quite important in genetically modified organisms (GMOs detection. To find a suitable endogenous reference gene and its real-time PCR assay for common wheat (Triticum aestivum L. DNA content or copy number quantification, four previously reported wheat endogenous reference genes and their real-time PCR assays were comprehensively evaluated for the target gene sequence variation and their real-time PCR performance among 37 common wheat lines. Three SNPs were observed in the PKABA1 and ALMT1 genes, and these SNPs significantly decreased the efficiency of real-time PCR amplification. GeNorm analysis of the real-time PCR performance of each gene among common wheat lines showed that the Waxy-D1 assay had the lowest M values with the best stability among all tested lines. All results indicated that the Waxy-D1 gene and its real-time PCR assay were most suitable to be used as an endogenous reference gene for common wheat DNA content quantification. The validated Waxy-D1 gene assay will be useful in establishing accurate and creditable qualitative and quantitative PCR analysis of GM wheat.

  13. Evaluation of Four Endogenous Reference Genes and Their Real-Time PCR Assays for Common Wheat Quantification in GMOs Detection

    Science.gov (United States)

    Huang, Huali; Cheng, Fang; Wang, Ruoan; Zhang, Dabing; Yang, Litao

    2013-01-01

    Proper selection of endogenous reference genes and their real-time PCR assays is quite important in genetically modified organisms (GMOs) detection. To find a suitable endogenous reference gene and its real-time PCR assay for common wheat (Triticum aestivum L.) DNA content or copy number quantification, four previously reported wheat endogenous reference genes and their real-time PCR assays were comprehensively evaluated for the target gene sequence variation and their real-time PCR performance among 37 common wheat lines. Three SNPs were observed in the PKABA1 and ALMT1 genes, and these SNPs significantly decreased the efficiency of real-time PCR amplification. GeNorm analysis of the real-time PCR performance of each gene among common wheat lines showed that the Waxy-D1 assay had the lowest M values with the best stability among all tested lines. All results indicated that the Waxy-D1 gene and its real-time PCR assay were most suitable to be used as an endogenous reference gene for common wheat DNA content quantification. The validated Waxy-D1 gene assay will be useful in establishing accurate and creditable qualitative and quantitative PCR analysis of GM wheat. PMID:24098735

  14. A Reference Viral Database (RVDB) To Enhance Bioinformatics Analysis of High-Throughput Sequencing for Novel Virus Detection.

    Science.gov (United States)

    Goodacre, Norman; Aljanahi, Aisha; Nandakumar, Subhiksha; Mikailov, Mike; Khan, Arifa S

    2018-01-01

    Detection of distantly related viruses by high-throughput sequencing (HTS) is bioinformatically challenging because of the lack of a public database containing all viral sequences, without abundant nonviral sequences, which can extend runtime and obscure viral hits. Our reference viral database (RVDB) includes all viral, virus-related, and virus-like nucleotide sequences (excluding bacterial viruses), regardless of length, and with overall reduced cellular sequences. Semantic selection criteria (SEM-I) were used to select viral sequences from GenBank, resulting in a first-generation viral database (VDB). This database was manually and computationally reviewed, resulting in refined, semantic selection criteria (SEM-R), which were applied to a new download of updated GenBank sequences to create a second-generation VDB. Viral entries in the latter were clustered at 98% by CD-HIT-EST to reduce redundancy while retaining high viral sequence diversity. The viral identity of the clustered representative sequences (creps) was confirmed by BLAST searches in NCBI databases and HMMER searches in PFAM and DFAM databases. The resulting RVDB contained a broad representation of viral families, sequence diversity, and a reduced cellular content; it includes full-length and partial sequences and endogenous nonretroviral elements, endogenous retroviruses, and retrotransposons. Testing of RVDBv10.2, with an in-house HTS transcriptomic data set indicated a significantly faster run for virus detection than interrogating the entirety of the NCBI nonredundant nucleotide database, which contains all viral sequences but also nonviral sequences. RVDB is publically available for facilitating HTS analysis, particularly for novel virus detection. It is meant to be updated on a regular basis to include new viral sequences added to GenBank. IMPORTANCE To facilitate bioinformatics analysis of high-throughput sequencing (HTS) data for the detection of both known and novel viruses, we have

  15. Entanglement detection with bounded reference frames

    International Nuclear Information System (INIS)

    Costa, Fabio; Brukner, Caslav; Harrigan, Nicholas; Rudolph, Terry

    2009-01-01

    Quantum experiments usually assume the existence of perfect, classical reference frames (RFs), which allow for the specification of measurement settings (e.g. orientation of the Stern-Gerlach magnet in spin measurements) with arbitrary precision. If the RFs are 'bounded' (i.e. quantum systems themselves, having a finite number of degrees of freedom), only limited precision can be attained. Using spin coherent states as bounded RFs, we have found the minimum size needed for them to violate local realism for entangled spin systems. For composite systems of spin 1/2 particles, RFs of very small size are sufficient for the violation; however, to see this violation for macroscopic entangled spins, the size of the RF must be at least quadratically larger than that of the spins. The unavailability of such RFs gives a possible explanation for the non-observance of violation of local realism in everyday experience.

  16. Detecting Postpartum Depression in Referents to Medical and Health Centers in Hamadan City

    Directory of Open Access Journals (Sweden)

    F. Shobeiri

    2007-10-01

    Full Text Available Introduction & Objective: Pregnancy and childbirth are significant developmental excitable for most women. Physical, intrapersonal and relational adaptations are needed to adjust successfully to pregnancy and delivery. Postpartum depression is a serious psychiatric disorder and the adverse impact on infants has been noted. The purpose of this study was to detect postpartum depression in referents to medical and health centers in Hamadan city.Materials & Methods: A descriptive and cross-sectional study involving 400 women completed the Beck Depression Inventory (BDI within 2-8 weeks of delivery was conducted in urban health centers in Hamadan city, Iran. Data were collected through interviews with women in the clinics in the health centers. Data processing and statistical analysis were performed using SPSS 10.0.Results: The results revealed that majority of women (68.0% were considered normal. Depression was detected in 32.0% of women. Out of these 19.0, 4.0 and 9.0% were mild, moderate and severe depression, respectively. There were statistically significant differences between postpartum depression and age, number of delivery, education, job and husband's job (P=0.000.Conclusion: Nearly 32.0% of selected women had depression. Therefore, it is important for medical personnel to be well versed in the course and treatment of postpartum depression. Post partum depression should be screened and treated as early as possible for several reasons. It can cause significant suffering for the woman who experiences it, and it can have deleterious consequences for the newborn.

  17. Cold dark matter dominated, inflationary universe with Omega(0) less than 1 and n less than 1

    International Nuclear Information System (INIS)

    Vittorio, N.; Matarrese, S.; Lucchin, F.

    1988-01-01

    The theoretical prejudice for a flat universe with an initially scale-invariant power spectrum has restricted the number of cosmological scenarios investigated for studying the formation of structure in the universe. A cold dark matter-dominated universe with a density parameter Omega(0) and a primordial spectral index n different from unity is considered, and its possible consistency with the inflationary model is discussed. It is shown that some of the difficulties of a flat cold dark matter scenario can be avoided by having Omega(0) less than 1 and n less than 1. For Omega(0) roughly 0.4 and n roughly 0.75 a good agreement is obtained with the large-scale drifts, the bounds on the cosmic microwave background smoothness, the Abell cluster abundance, and their correlation function. 85 references

  18. Bacteriological detection of Salmonella in the presence of competitive micro-organisms. Bacteriological collaborative study IV amongst the National Reference Laboratories for Salmonella, the use of MSRV as selective enrichment

    NARCIS (Netherlands)

    Raes M; Nagelkerke N; Henken AM; MGB; IMA

    2000-01-01

    A fourth bacteriological collaborative study was organised by the Community Reference Laboratory for Salmonella. All National Reference Laboratories for Salmonella (NRLs) participated. This study had two objectives: 1) Evaluation of the results of the detection of different contamination levels of

  19. Reference material manufacture and certification for the AVNG

    Energy Technology Data Exchange (ETDEWEB)

    Hauck, Danielle K [Los Alamos National Laboratory; Thron, Jonathan [Los Alamos National Laboratory; MacArthur, Duncan W. [Los Alamos National Laboratory; Livke, Alexander [RFNC - VNIIEF; Bulatov, M [RFNC-VNIIEF; Kondratov, Sergey [RFNC-VNIIEF; Leplyavkina, M [RFNC-VNIIEF; Razinkov, Sergey [RFNC-VNIIEF; Sivachev, D [RFNC-VNIIEF; Tsybryaev, S [RFNC-VNIIEF; V' yushin, A [RFNC-VNIIEF

    2010-07-09

    Testing and demonstration of any radiation measurement system requires the use of appropriate radioactive sources. An attribute measurement system (A VNG) was developed and fabricated at the Russian Federal Nuclear Center, VNIIEF, Russia, under contract with LANL, USA. The A VNG detects neutron and gamma radiation signatures and compares the data analysis results with the specified threshold values for three unclassified attributes; plutonium is present or absent, plutonium mass is greater than or less than the specified threshold value and plutonium isotopic ratio 240Pu to 239Pu) is greater than or less then the threshold value. A set of reference materials (RMs) was specially manufactured for the A VNG with masses and isotopic ratios above and below the selected thresholds. The set of RMs was certified in compliance with the Russian metrological requirements. The RMs were used to debug and test the A VNG and to demonstrate the A VNG operation to an American delegation in June 2009. In this presentation, we will describe the various steps in the manufacture and certification of these RM sources.

  20. Reference material manufacture and certification for the AVNG

    International Nuclear Information System (INIS)

    2010-01-01

    Testing and demonstration of any radiation measurement system requires the use of appropriate radioactive sources. An attribute measurement system (A VNG) was developed and fabricated at the Russian Federal Nuclear Center, VNIIEF, Russia, under contract with LANL, USA. The A VNG detects neutron and gamma radiation signatures and compares the data analysis results with the specified threshold values for three unclassified attributes; plutonium is present or absent, plutonium mass is greater than or less than the specified threshold value and plutonium isotopic ratio 240 Pu to 239 Pu) is greater than or less then the threshold value. A set of reference materials (RMs) was specially manufactured for the A VNG with masses and isotopic ratios above and below the selected thresholds. The set of RMs was certified in compliance with the Russian metrological requirements. The RMs were used to debug and test the A VNG and to demonstrate the A VNG operation to an American delegation in June 2009. In this presentation, we will describe the various steps in the manufacture and certification of these RM sources.

  1. A RVI/LAI-reference curve to detect N stress and guide N fertigation using combined information from spectral reflectance and leaf area measurements in potato

    DEFF Research Database (Denmark)

    Zhenjiang, Zhou; Plauborg, Finn; Thomsen, Anton Gårde

    2017-01-01

    More user-friendly methods are needed to detect crop N status/stress and guide the timing of in-season N application. In the current study, a reference curve method of detecting N stress was proposed to remedy practical problems of methods that require leaf sampling or maintaining a N sufficient...... was applied during the season. The total N ranged from 0 to180 kg N ha−1. RVI and LAI from the economically optimum 180 kg N ha−1 treatments were used to derive the reference curve. RVI and LAI from 180 kg N ha−1 treatment had a high (R2 = 0.97) correlation and were best fitted with a 2nd order polynomial...... function, which was independent of season. The treatments where N fertigation was stopped before reaching 180 kg N ha−1 started to deviate from the 95% confidence interval of the reference curve about 10 days after N-fertigation was stopped. This corresponded to 10–20 kg ha−1 difference in total plant N...

  2. Wheat-specific gene, ribosomal protein l21, used as the endogenous reference gene for qualitative and real-time quantitative polymerase chain reaction detection of transgenes.

    Science.gov (United States)

    Liu, Yi-Ke; Li, He-Ping; Huang, Tao; Cheng, Wei; Gao, Chun-Sheng; Zuo, Dong-Yun; Zhao, Zheng-Xi; Liao, Yu-Cai

    2014-10-29

    Wheat-specific ribosomal protein L21 (RPL21) is an endogenous reference gene suitable for genetically modified (GM) wheat identification. This taxon-specific RPL21 sequence displayed high homogeneity in different wheat varieties. Southern blots revealed 1 or 3 copies, and sequence analyses showed one amplicon in common wheat. Combined analyses with sequences from common wheat (AABBDD) and three diploid ancestral species, Triticum urartu (AA), Aegilops speltoides (BB), and Aegilops tauschii (DD), demonstrated the presence of this amplicon in the AA genome. Using conventional qualitative polymerase chain reaction (PCR), the limit of detection was 2 copies of wheat haploid genome per reaction. In the quantitative real-time PCR assay, limits of detection and quantification were about 2 and 8 haploid genome copies, respectively, the latter of which is 2.5-4-fold lower than other reported wheat endogenous reference genes. Construct-specific PCR assays were developed using RPL21 as an endogenous reference gene, and as little as 0.5% of GM wheat contents containing Arabidopsis NPR1 were properly quantified.

  3. Exploring Staff-Less Libraries as Social Space

    DEFF Research Database (Denmark)

    Engström, Lisa

    Today, public libraries in several countries have introduced staff-less opening hours. The term “staff-less library” refers to a public library that during some of the opening hours are without library staff available to the users, but the library is open for users to enter and use its services....... In staff-less libraries, users need to manage the library on their own. In this paper the following question is explored; how is increased self-management related to users self-governing and to users being governed in the library. In addition, methodological issues and the utilization of interviews...... and observations in relation to the library as place are investigated. The governing of users, or governmentality, is situated at the physical library and the library as place is vital to the research. One early finding discussed in this paper is the notion of the library as meeting place and how users actually...

  4. Development of an experimental investigation of some theories of relativity by daytime astrometry

    International Nuclear Information System (INIS)

    Ballard, P.T.

    1978-01-01

    This work describes an experiment, now in progress, to observe planet-sun separations through conjunction in full daylight. It is hoped to show that by these observations new limits are imposed on existing or future theories of gravitation. The nature of the experiment as well as some details of the experimental apparatus are presented. In addition, detailed calculations are presented which address the rather general problem of phase sensitive detection of a shot noise limited signal. Some other problems arising from this experiment are introduced but no conclusion is or can be presented at this time. These include the apparent oscillations of the solar diameter, a length reference in the field of the telescope, and the interferometric reduction of unwanted background radiation. Finally, a preliminary analysis of the intended observations is presented illustrating the sensitivity of the observations to various effects of gravitational importance

  5. Optical atomic phase reference and timing

    Science.gov (United States)

    Hollberg, L.; Cornell, E. H.; Abdelrahmann, A.

    2017-06-01

    Atomic clocks based on laser-cooled atoms have made tremendous advances in both accuracy and stability. However, advanced clocks have not found their way into widespread use because there has been little need for such high performance in real-world/commercial applications. The drive in the commercial world favours smaller, lower-power, more robust compact atomic clocks that function well in real-world non-laboratory environments. Although the high-performance atomic frequency references are useful to test Einstein's special relativity more precisely, there are not compelling scientific arguments to expect a breakdown in special relativity. On the other hand, the dynamics of gravity, evidenced by the recent spectacular results in experimental detection of gravity waves by the LIGO Scientific Collaboration, shows dramatically that there is new physics to be seen and understood in space-time science. Those systems require strain measurements at less than or equal to 10-20. As we discuss here, cold atom optical frequency references are still many orders of magnitude away from the frequency stability that should be achievable with narrow-linewidth quantum transitions and large numbers of very cold atoms, and they may be able to achieve levels of phase stability, ΔΦ/Φtotal ≤ 10-20, that could make an important impact in gravity wave science. This article is part of the themed issue 'Quantum technology for the 21st century'.

  6. Detecting atmospheric normal modes with periods less than 6 h by barometric observations

    Science.gov (United States)

    Ermolenko, S. I.; Shved, G. M.; Jacobi, Ch.

    2018-04-01

    The theory of atmospheric normal modes (ANMs) predicts the existence of relatively short-period gravity-inertia ANMs. Simultaneous observations of surface air-pressure variations by barometers at distant stations of the Global Geodynamics Project network during an interval of 6 months were used to detect individual gravity-inertia ANMs with periods of ∼2-5 h. Evidence was found for five ANMs with a lifetime of ∼10 days. The data of the stations, which are close in both latitude and longitude, were utilized for deriving the phases of the detected ANMs. The phases revealed wave propagation to the west and increase of zonal wavenumbers with frequency. As all the detected gravity-inertia ANMs are westward propagating, they are suggested to be generated due to the breakdown of migrating solar tides and/or large-scale Rossby waves. The existence of an ANM background will complicate the detection of the translational motions of the Earth's inner core.

  7. A reference standard-based quality assurance program for radiology.

    Science.gov (United States)

    Liu, Patrick T; Johnson, C Daniel; Miranda, Rafael; Patel, Maitray D; Phillips, Carrie J

    2010-01-01

    The authors have developed a comprehensive radiology quality assurance (QA) program that evaluates radiology interpretations and procedures by comparing them with reference standards. Performance metrics are calculated and then compared with benchmarks or goals on the basis of published multicenter data and meta-analyses. Additional workload for physicians is kept to a minimum by having trained allied health staff members perform the comparisons of radiology reports with the reference standards. The performance metrics tracked by the QA program include the accuracy of CT colonography for detecting polyps, the false-negative rate for mammographic detection of breast cancer, the accuracy of CT angiography detection of coronary artery stenosis, the accuracy of meniscal tear detection on MRI, the accuracy of carotid artery stenosis detection on MR angiography, the accuracy of parathyroid adenoma detection by parathyroid scintigraphy, the success rate for obtaining cortical tissue on ultrasound-guided core biopsies of pelvic renal transplants, and the technical success rate for peripheral arterial angioplasty procedures. In contrast with peer-review programs, this reference standard-based QA program minimizes the possibilities of reviewer bias and erroneous second reviewer interpretations. The more objective assessment of performance afforded by the QA program will provide data that can easily be used for education and management conferences, research projects, and multicenter evaluations. Additionally, such performance data could be used by radiology departments to demonstrate their value over nonradiology competitors to referring clinicians, hospitals, patients, and third-party payers. Copyright 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  8. NASCAP programmer's reference manual

    Science.gov (United States)

    Mandell, M. J.; Stannard, P. R.; Katz, I.

    1993-05-01

    The NASA Charging Analyzer Program (NASCAP) is a computer program designed to model the electrostatic charging of complicated three-dimensional objects, both in a test tank and at geosynchronous altitudes. This document is a programmer's reference manual and user's guide. It is designed as a reference to experienced users of the code, as well as an introduction to its use for beginners. All of the many capabilities of NASCAP are covered in detail, together with examples of their use. These include the definition of objects, plasma environments, potential calculations, particle emission and detection simulations, and charging analysis.

  9. New method for determining free core nutation parameters, considering geophysical effects

    Czech Academy of Sciences Publication Activity Database

    Vondrák, Jan; Ron, Cyril

    2017-01-01

    Roč. 604, August (2017), A56/1-A56/7 E-ISSN 1432-0746 R&D Projects: GA ČR GA13-15943S Institutional support: RVO:67985815 Keywords : astrometry * reference systems * Earth Subject RIV: BN - Astronomy , Celestial Mechanics, Astrophysics OBOR OECD: Astronomy (including astrophysics,space science) Impact factor: 5.014, year: 2016

  10. Continuing Improvement in the Planetary Ephemeris with VLBA Observations of Cassini

    Science.gov (United States)

    Jones, Dayton L.; Folkner, William M.; Jacobson, Robert A.; Jacobs, Christopher S.; Romney, Jonathan D.; Dhawan, Vivek; Fomalont, Edward B.

    2016-06-01

    During the past decade a continuing series of measurements of the barycentric position of the Saturn system in the inertial International Celestial Reference Frame (ICRF) has led to a significant improvement in our knowledge of Saturn's orbit. This in turn has improved the current accuracy and time range of the solar system ephemeris produced and maintained by the Jet Propulsion Laboratory. Our observing technique involves high-precision astrometry of the radio signal from Cassini with the NRAO Very Long Baseline Array, combined with solutions for the orbital motion of Cassini about the Saturn barycenter from Doppler tracking by the Deep Space Network. Our VLBA astrometry is done in a phase-referencing mode, providing nrad-level relative positions between Cassini and angularly nearby extragalactic radio sources. The positions of those reference radio sources are tied to the ICRF through dedicated VLBI observations by several groups around the world. We will present recent results from our astrometric observations of Cassini through early 2016. This program will continue until the end of the Cassini mission in 2017, although future improvement in Saturn's orbit will be more incremental because we have already covered more that a quarter of Saturn's orbital period. The Juno mission to Jupiter, which will orbit Jupiter for about 1.5 years starting in July 2016, will provide an excellent opportunity for us to apply the same VLBA astrometry technique to improve the orbit of Jupiter by a factor of several. The National Radio Astronomy Observatory is a facility of the National Science Foundation operated under cooperative agreement by Associated Universities, Inc. This work made use of the Swinburne University of Technology software correlator, developed as part of the Australian Major National Research Facilities Program and operated under license. Part of this research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under contract

  11. Metaphorical Singular Reference. The Role of Enriched Composition in Reference Resolution

    Directory of Open Access Journals (Sweden)

    Anne Bezuidenhout

    2008-08-01

    Full Text Available It is widely accepted that, in the course of interpreting a metaphorical utterance, both literal and metaphorical interpretations of the utterance are available to the interpreter, although there may be disagreement about the order in which these interpretations are accessed. I call this the dual availability assumption. I argue that it does not apply in cases of metaphorical singular reference. These are cases in which proper names, complex demonstratives or definite descriptions are used metaphorically; e.g., ‘That festering sore must go’, referring to a derelict house. We are forced to give up dual availability in these cases because a process of predicate transfer happens in the restriction clauses of such metaphorically used definite phrases (DPs, so that a denotation-less definite concept is never constructed. A process of enriched composition yields only a metaphorical referent/denotation. I compare cases of metaphorical reference both to cases of metonymic reference and to uses of epithets of the ‘That N of an N’ form. Reflection on the former is helpful in getting clear about the kind of property transfer involved in referential metaphors. Such transfer happens directly at the level of properties and is not mediated via a correspondence between objects, as is the case with metonymic reference. Reflection on epithets such as ‘that festering sore of a house’ is helpful since these are a sort of intermediate case between cases of literal and metaphorical reference. They provide support for my claim that in cases of metaphorical reference there is only a single referent (the metaphorical one. Moreover, constraints on the use of these epithets suggest that referential metaphors are similarly constrained. In particular, I argue that referential metaphors can only be used when the implicit category restriction (e.g., house in the case of the example ‘That festering sore must go’ is highly salient, and that the evaluative

  12. Astrometric surveys in the Gaia era

    Science.gov (United States)

    Zacharias, Norbert

    2018-04-01

    The Gaia first data release (DR1) already provides an almost error free optical reference frame on the milli-arcsecond (mas) level allowing significantly better calibration of ground-based astrometric data than ever before. Gaia DR1 provides positions, proper motions and trigonometric parallaxes for just over 2 million stars in the Tycho-2 catalog. For over 1.1 billion additional stars DR1 gives positions. Proper motions for these, mainly fainter stars (G >= 11.5) are currently provided by several new projects which combine earlier epoch ground-based observations with Gaia DR1 positions. These data are very helpful in the interim period but will become obsolete with the second Gaia data release (DR2) expected in April 2018. The era of traditional, ground-based, wide-field astrometry with the goal to provide accurate reference stars has come to an end. Future ground-based astrometry will fill in some gaps (very bright stars, observations needed at many or specific epochs) and mainly will go fainter than the Gaia limit, like the PanSTARRS and the upcoming LSST surveys.

  13. Astrometric Results of NEOs from the Characterization and Astrometric Follow-up Program at Adler Planetarium

    Science.gov (United States)

    Nault, Kristie A.; Brucker, Melissa J.; Hammergren, Mark; Gyuk, Geza; Solontoi, Mike R.

    2015-11-01

    We present astrometric results of near-Earth objects (NEOs) targeted in fourth quarter 2014 and in 2015. This is part of Adler Planetarium’s NEO characterization and astrometric follow-up program, which uses the Astrophysical Research Consortium (ARC) 3.5-m telescope at Apache Point Observatory (APO). The program utilizes a 17% share of telescope time, amounting to a total of 500 hours per year. This time is divided up into two hour observing runs approximately every other night for astrometry and frequent half-night runs approximately several times a month for spectroscopy (see poster by M. Hammergren et. al.) and light curve studies (see poster by M. J. Brucker et. al.).Observations were made using Seaver Prototype Imaging Camera (SPIcam), a visible-wavelength, direct imaging CCD camera with 2048 x 2048 pixels and a field of view of 4.78’ x 4.78’. Observations were made using 2 x 2 binning.Special emphasis has been made to focus on the smallest NEOs, particularly around 140m in diameter. Targets were selected based on absolute magnitude (prioritizing for those with H > 25 mag to select small objects) and a 3σ uncertainty less than 400” to ensure that the target is in the FOV. Targets were drawn from the Minor Planet Center (MPC) NEA Observing Planning Aid, the JPL What’s Observable tool, and the Spaceguard priority list and faint NEO list.As of August 2015, we have detected 670 NEOs for astrometric follow-up, on point with our goal of providing astrometry on a thousand NEOs per year. Astrometric calculations were done using the interactive software tool Astrometrica, which is used for data reduction focusing on the minor bodies of the solar system. The program includes automatic reference star identification from new-generation star catalogs, access to the complete MPC database of orbital elements, and automatic moving object detection and identification.This work is based on observations done using the 3.5-m telescope at Apache Point Observatory

  14. Digital reference service : libraries online 24/7

    OpenAIRE

    Vijayakumar, Manju; Vijayakumar, J. K.

    2005-01-01

    The integration of the Internet Technology in to Libraries has not changed its mission of providing excellent information service to users but it has added several new dimensions and opened new avenues to their tasks. Reference librarians, while assisting users in the library, now have an additional set of remote users, who access the reference service online, who are more demanding, less patient users who have greater expectations. This paper discusses the methods in Online Reference service...

  15. A low temperature drift coefficient crystal-less frequency reference clock compensated by temperature sensor for microsystem

    Science.gov (United States)

    Gao, Zhiqiang; Wu, Ruixuan; Wang, Yuteng; Gao, Yuan; Liu, Xiaowei; Zhu, Jiaqi

    2018-05-01

    Quartz oscillator has been widely used as reference clock source in the microsystems due to its good performance. But a good crystal oscillator costs too much and its bulky size is not desired. This paper aims at designing an alternative integrated oscillator to replace the external quartz oscillator. The proposed circuit used maneatis delay cell to construct a ring oscillator for its superior linear I-V characteristic. As for a frequency reference clock, its frequency stability over temperature is required at first. After detailed mathematical deducing and careful analysis, a formula is proposed to describe the relationship between desired control voltage and temperature by assuming the frequency as constant. This paper utilized bipolar transistor as the temperature sensor, combining it with CTAT current source and resistor to create a first-order temperature compensation control voltage. The chip with typical frequency of 10 MHz was fabricated in a 0.35 μm CMOS technology and occupied 0.45 mm2. The measured results show that the frequency variation is ±0.2% for supply changes from 4.8 V to 5 V, and frequency variation is 48 ppm when the temperature change is from ‑40∘C to 85∘C, while the average current of the tested chip consumes 50 μA from 5 V.

  16. Dynamic computed tomography in various hepatic diseases. Particular reference to detection and differential diagnosis of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa

    1985-03-01

    Studied were 140 cases of hepatoma, 40 of metastatic liver tumor, 18 of hemangioma, 9 of liver cirrhosis, 10 of chronic hepatitis and 10 patients with no liver disease. The dynamic CT was obtained before, 10, 30 and 50 seconds after an intravenous bolus injection of 50 ml of 65 % meglumine diatrizoate. Normal liver parenchyma and portal vein were slightly enhanced on the arterial phase and moderately enhanced on the portal phase of the dynamic CT. There was no significant change in case of chronic hepatitis, but in case of liver cirrhosis, the liver parenchyma was less enhanced than the normal liver on the portal phase. Tumor enhancement on the arterial phase was classified into 6 patterns, namely, A : homogeneous, B : inhomogeneous, C : patchy, D : ring, E : peripheral and F : no enhancement, while time-density-change was classified into 4 types, namely, type I : the tumor was most enhanced on the arterial phase, type II : the tumor was most enhanced on the portal phase, type III : tumor enhancement increased with time, type IV : there were no significant changes with time. Hepatoma was characterized by patterns A, B and C tumor enhancement and type I time-density-change, while metastatic liver tumor featured patterns D and F tumor enhancement and hemangioma was characteristic in indicating pattern E tumor enhancement and type III time-density-change. The rate of accurate diagnosis was 92 %. Small hepatoma (less than 5 cm in diameter) could be detected by conventional CT only in 38 out of 50 cases (76 %), while dynamic CT revealed an additional 8 cases. Out of 21 cases of portal vein thrombosis, 14 cases (66.7 %) were detected by the conventional CT but dynamic CT improved the rate of detection to 92.0 %. Dynamic CT also revealed 6 cases of arterioportal shunt which could not be detected at all by conventional CT. Thus dynamic CT provides useful information and should be considered as one of the routine tests in CT examination of the liver. (J.P.N.).

  17. Optical atomic phase reference and timing.

    Science.gov (United States)

    Hollberg, L; Cornell, E H; Abdelrahmann, A

    2017-08-06

    Atomic clocks based on laser-cooled atoms have made tremendous advances in both accuracy and stability. However, advanced clocks have not found their way into widespread use because there has been little need for such high performance in real-world/commercial applications. The drive in the commercial world favours smaller, lower-power, more robust compact atomic clocks that function well in real-world non-laboratory environments. Although the high-performance atomic frequency references are useful to test Einstein's special relativity more precisely, there are not compelling scientific arguments to expect a breakdown in special relativity. On the other hand, the dynamics of gravity, evidenced by the recent spectacular results in experimental detection of gravity waves by the LIGO Scientific Collaboration, shows dramatically that there is new physics to be seen and understood in space-time science. Those systems require strain measurements at less than or equal to 10 -20 As we discuss here, cold atom optical frequency references are still many orders of magnitude away from the frequency stability that should be achievable with narrow-linewidth quantum transitions and large numbers of very cold atoms, and they may be able to achieve levels of phase stability, Δ Φ / Φ total  ≤ 10 -20 , that could make an important impact in gravity wave science.This article is part of the themed issue 'Quantum technology for the 21st century'. © 2017 The Author(s).

  18. Real-time polymerase chain reaction assay for endogenous reference gene for specific detection and quantification of common wheat-derived DNA (Triticum aestivum L.).

    Science.gov (United States)

    Vautrin, Sonia; Zhang, David

    2007-01-01

    A species-specific endogenous reference gene system was developed for polymerase chain reaction (PCR)-based analysis in common wheat (Triticum aestivum L.) by targeting the ALMT1 gene, an aluminium-activated malate transporter. The primers and probe were elaborated for real-time PCR-based qualitative and quantitative assay. The size of amplified product is 95 base pairs. The specificity was assessed on 17 monocot and dicot plant species. The established real-time PCR assay amplified only T. aestivum-derived DNA; no amplification occurred on other phylogenetically related species, including durum wheat (T. durum). The robustness of the system was tested on the DNA of 15 common wheat cultivars using 20 000 genomic copies per PCR the mean cycle threshold (Ct) values of 24.02 +/- 0.251 were obtained. The absolute limits of detection and quantification of the real-time PCR assay were estimated to 2 and 20 haploid genome copies of common wheat, respectively. The linearity was experimentally validated on 2-fold serial dilutions of DNA from 650 to 20 000 haploid genome copies. All these results show that the real-time PCR assay developed on the ALMT1 gene is suitable to be used as an endogenous reference gene for PCR-based specific detection and quantification of T. aestivum-derived DNA in various applications, in particular for the detection and quantification of genetically modified materials in common wheat.

  19. VizieR Online Data Catalog: Hubble Source Catalog (V1 and V2) (Whitmore+, 2016)

    Science.gov (United States)

    Whitmore, B. C.; Allam, S. S.; Budavari, T.; Casertano, S.; Downes, R. A.; Donaldson, T.; Fall, S. M.; Lubow, S. H.; Quick, L.; Strolger, L.-G.; Wallace, G.; White, R. L.

    2016-10-01

    The HSC v1 contains members of the WFPC2, ACS/WFC, WFC3/UVIS and WFC3/IR Source Extractor source lists from HLA version DR8 (data release 8). The crossmatching process involves adjusting the relative astrometry of overlapping images so as to minimize positional offsets between closely aligned sources in different images. After correction, the astrometric residuals of crossmatched sources are significantly reduced, to typically less than 10mas. The relative astrometry is supported by using Pan-STARRS, SDSS, and 2MASS as the astrometric backbone for initial corrections. In addition, the catalog includes source nondetections. The crossmatching algorithms and the properties of the initial (Beta 0.1) catalog are described in Budavari & Lubow (2012ApJ...761..188B). The HSC v2 contains members of the WFPC2, ACS/WFC, WFC3/UVIS and WFC3/IR Source Extractor source lists from HLA version DR9.1 (data release 9.1). The crossmatching process involves adjusting the relative astrometry of overlapping images so as to minimize positional offsets between closely aligned sources in different images. After correction, the astrometric residuals of crossmatched sources are significantly reduced, to typically less than 10mas. The relative astrometry is supported by using Pan-STARRS, SDSS, and 2MASS as the astrometric backbone for initial corrections. In addition, the catalog includes source nondetections. The crossmatching algorithms and the properties of the initial (Beta 0.1) catalog are described in Budavari & Lubow (2012ApJ...761..188B). Hubble Source Catalog Acknowledgement: Based on observations made with the NASA/ESA Hubble Space Telescope, and obtained from the Hubble Legacy Archive, which is a collaboration between the Space Telescope Science Institute (STScI/NASA), the Space Telescope European Coordinating Facility (ST-ECF/ESAC/ESA) and the Canadian Astronomy Data Centre (CADC/NRC/CSA). (2 data files).

  20. Certification of caffeine reference material purity by ultraviolet/visible spectrophotometry and high-performance liquid chromatography with diode-array detection as two independent analytical methods.

    Science.gov (United States)

    Shehata, A B; Rizk, M S; Rend, E A

    2016-10-01

    Caffeine reference material certified for purity is produced worldwide, but no research work on the details of the certification process has been published in the literature. In this paper, we report the scientific details of the preparation and certification of pure caffeine reference materials. Caffeine was prepared by extraction from roasted and ground coffee by dichloromethane after heating in deionized water mixed with magnesium oxide. The extract was purified, dried, and bottled in dark glass vials. Stratified random selection was applied to select a number of vials for homogeneity and stability studies, which revealed that the prepared reference material is homogeneous and sufficiently stable. Quantification of caffeine purity % was carried out using a calibrated UV/visible spectrophotometer and a calibrated high-performance liquid chromatography with diode-array detection method. The results obtained from both methods were combined to drive the certified value and its associated uncertainty. The certified value of the reference material purity was found to be 99.86% and its associated uncertainty was ±0.65%, which makes the candidate reference material a very useful calibrant in food and drug chemical analysis. Copyright © 2016. Published by Elsevier B.V.

  1. Certification of caffeine reference material purity by ultraviolet/visible spectrophotometry and high-performance liquid chromatography with diode-array detection as two independent analytical methods

    Directory of Open Access Journals (Sweden)

    A.B. Shehata

    2016-10-01

    Full Text Available Caffeine reference material certified for purity is produced worldwide, but no research work on the details of the certification process has been published in the literature. In this paper, we report the scientific details of the preparation and certification of pure caffeine reference materials. Caffeine was prepared by extraction from roasted and ground coffee by dichloromethane after heating in deionized water mixed with magnesium oxide. The extract was purified, dried, and bottled in dark glass vials. Stratified random selection was applied to select a number of vials for homogeneity and stability studies, which revealed that the prepared reference material is homogeneous and sufficiently stable. Quantification of caffeine purity % was carried out using a calibrated UV/visible spectrophotometer and a calibrated high-performance liquid chromatography with diode-array detection method. The results obtained from both methods were combined to drive the certified value and its associated uncertainty. The certified value of the reference material purity was found to be 99.86% and its associated uncertainty was ±0.65%, which makes the candidate reference material a very useful calibrant in food and drug chemical analysis.

  2. Detection of a faint fast-moving near-Earth asteroid using the synthetic tracking technique

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, Chengxing; Shao, Michael; Nemati, Bijan; Werne, Thomas; Zhou, Hanying; Turyshev, Slava G.; Sandhu, Jagmit [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States); Hallinan, Gregg; Harding, Leon K., E-mail: chengxing.zhai@jpl.nasa.gov [Department of Astronomy, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 (United States)

    2014-09-01

    We report a detection of a faint near-Earth asteroid (NEA) using our synthetic tracking technique and the CHIMERA instrument on the Palomar 200 inch telescope. With an apparent magnitude of 23 (H = 29, assuming detection at 20 lunar distances), the asteroid was moving at 6.°32 day{sup –1} and was detected at a signal-to-noise ratio (S/N) of 15 using 30 s of data taken at a 16.7 Hz frame rate. The detection was confirmed by a second observation 77 minutes later at the same S/N. Because of its high proper motion, the NEA moved 7 arcsec over the 30 s of observation. Synthetic tracking avoided image degradation due to trailing loss that affects conventional techniques relying on 30 s exposures; the trailing loss would have degraded the surface brightness of the NEA image on the CCD down to an approximate magnitude of 25 making the object undetectable. This detection was a result of our 12 hr blind search conducted on the Palomar 200 inch telescope over two nights, scanning twice over six (5.°3 × 0.°046) fields. Detecting only one asteroid is consistent with Harris's estimates for the distribution of the asteroid population, which was used to predict a detection of 1.2 NEAs in the H-magnitude range 28-31 for the two nights. The experimental design, data analysis methods, and algorithms are presented. We also demonstrate milliarcsecond-level astrometry using observations of two known bright asteroids on the same system with synthetic tracking. We conclude by discussing strategies for scheduling observations to detect and characterize small and fast-moving NEAs using the new technique.

  3. Analytical validation of a reference laboratory ELISA for the detection of feline leukemia virus p27 antigen.

    Science.gov (United States)

    Buch, Jesse S; Clark, Genevieve H; Cahill, Roberta; Thatcher, Brendon; Smith, Peter; Chandrashekar, Ramaswamy; Leutenegger, Christian M; O'Connor, Thomas P; Beall, Melissa J

    2017-09-01

    Feline leukemia virus (FeLV) is an oncogenic retrovirus of cats. Immunoassays for the p27 core protein of FeLV aid in the detection of FeLV infections. Commercial microtiter-plate ELISAs have rapid protocols and visual result interpretation, limiting their usefulness in high-throughput situations. The purpose of our study was to validate the PetChek FeLV 15 ELISA, which is designed for the reference laboratory, and incorporates sequential, orthogonal screening and confirmatory protocols. A cutoff for the screening assay was established with 100% accuracy using 309 feline samples (244 negative, 65 positive) defined by the combined results of FeLV PCR and an independent reference p27 antigen ELISA. Precision of the screening assay was measured using a panel of 3 samples (negative, low-positive, and high-positive). The intra-assay coefficient of variation (CV) was 3.9-7.9%; the inter-assay CV was 6.0-8.6%. For the confirmatory assay, the intra-assay CV was 3.0-4.7%, and the inter-assay CV was 7.4-9.7%. The analytical sensitivity for p27 antigen was 3.7 ng/mL for inactivated whole FeLV and 1.2 ng/mL for purified recombinant FeLV p27. Analytical specificity was demonstrated based on the absence of cross-reactivity to related retroviruses. No interference was observed for samples containing added bilirubin, hemoglobin, or lipids. Based on these results, the new high-throughput design of the PetChek FeLV 15 ELISA makes it suitable for use in reference laboratory settings and maintains overall analytical performance.

  4. Laser-to-RF phase detection with femtosecond precision for remote reference phase stabilization in particle accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Lamb, Thorsten

    2017-05-15

    The operation of modern free-electron lasers (FELs) requires the synchronization of different accelerator subsystems with femtosecond precision. A pulsed optical synchronization system is for this reason operated at the Free-Electron Laser in Hamburg (FLASH) and it is under construction for the upcoming European X-ray Free-Electron Laser (XFEL). Laser pulses from the optical master oscillator are transmitted by timing stabilized optical fiberlinks to dedicated end stations along the accelerator. Devices which cannot operate with optical synchronization signals are instead conventionally synchronized with radio frequency (RF) reference signals. These signals are distributed in the accelerator by coaxial cables. Especially the low -level radio frequency (LLRF) system requires RF reference signals with femtosecond stability in order to meet nowadays femtosecond demands. Due to cable drifts and the length of the accelerators, this level of stability cannot be provided by conventional RF transport. A laser-to-RF (L2RF) phase detector has been invented, which allows to measure with femtosecond precision the relative phase between a phase stable optical pulse train from an optical fiberlink and an RF signal. The L2RF phase detector is based on an integrated MACH-ZEHNDER modulator (MZM) in which the phase error between both signals is encoded in an amplitude modulation of the optical pulse train. Different configurations, based on single output and dual output MZMs have been evaluated for different operation scenarios. A full mathematical representation of the chosen configuration has been derived. The impact of multiple error sources has been investigated. It has been proven that most error sources have only second or higher order influence on the detection principle which is a significant advantage over existing schemes. The invented L2RF phase detector is for example balanced and in its working point insensitive to power variations of the optical reference pulse train

  5. Laser-to-RF phase detection with femtosecond precision for remote reference phase stabilization in particle accelerators

    International Nuclear Information System (INIS)

    Lamb, Thorsten

    2017-05-01

    The operation of modern free-electron lasers (FELs) requires the synchronization of different accelerator subsystems with femtosecond precision. A pulsed optical synchronization system is for this reason operated at the Free-Electron Laser in Hamburg (FLASH) and it is under construction for the upcoming European X-ray Free-Electron Laser (XFEL). Laser pulses from the optical master oscillator are transmitted by timing stabilized optical fiberlinks to dedicated end stations along the accelerator. Devices which cannot operate with optical synchronization signals are instead conventionally synchronized with radio frequency (RF) reference signals. These signals are distributed in the accelerator by coaxial cables. Especially the low -level radio frequency (LLRF) system requires RF reference signals with femtosecond stability in order to meet nowadays femtosecond demands. Due to cable drifts and the length of the accelerators, this level of stability cannot be provided by conventional RF transport. A laser-to-RF (L2RF) phase detector has been invented, which allows to measure with femtosecond precision the relative phase between a phase stable optical pulse train from an optical fiberlink and an RF signal. The L2RF phase detector is based on an integrated MACH-ZEHNDER modulator (MZM) in which the phase error between both signals is encoded in an amplitude modulation of the optical pulse train. Different configurations, based on single output and dual output MZMs have been evaluated for different operation scenarios. A full mathematical representation of the chosen configuration has been derived. The impact of multiple error sources has been investigated. It has been proven that most error sources have only second or higher order influence on the detection principle which is a significant advantage over existing schemes. The invented L2RF phase detector is for example balanced and in its working point insensitive to power variations of the optical reference pulse train

  6. Health-related quality of life in adolescents with screening-detected celiac disease, before and one year after diagnosis and initiation of gluten-free diet, a prospective nested case-referent study

    Directory of Open Access Journals (Sweden)

    Nordyke Katrina

    2013-02-01

    Full Text Available Abstract Background Celiac disease (CD is a chronic disorder in genetically predisposed individuals in which a small intestinal immune-mediated enteropathy is precipitated by dietary gluten. It can be difficult to diagnose because signs and symptoms may be absent, subtle, or not recognized as CD related and therefore not prompt testing within routine clinical practice. Thus, most people with CD are undiagnosed and a public health intervention, which involves screening the general population, is an option to find those with unrecognized CD. However, how these screening-detected individuals experience the diagnosis and treatment (gluten-free diet is not fully understood. The aim of this study is to investigate the health-related quality of life (HRQoL of adolescents with screening-detected CD before and one year after diagnosis and treatment. Methods A prospective nested case-referent study was done involving Swedish adolescents who had participated in a CD screening study when they were in the sixth grade and about 12 years old. Screening-detected adolescents (n = 103 and referents without CD who participated in the same screening (n = 483 answered questionnaires at the time of the screening and approximately one year after the screening-detected adolescents had received their diagnosis that included the EQ-5D instrument used to measure health status and report HRQoL. Results The HRQoL for the adolescents with screening-detected CD is similar to the referents, both before and one year after diagnosis and initiation of the gluten-free diet, except in the dimension of pain at follow-up. In the pain dimension at follow-up, fewer cases reported problems than referents (12.6% and 21.9% respectively, Adjusted OR 0.50, 95% CI 0.27-0.94. However, a sex stratified analysis revealed that the significant difference was for boys at follow-up, where fewer screening-detected boys reported problems (4.3% compared to referent boys (18.8% (Adjusted OR 0

  7. Earth orientation parameters based on EOC-4 astrometric catalog

    Czech Academy of Sciences Publication Activity Database

    Vondrák, Jan; Ron, Cyril; Štefka, Vojtěch

    2010-01-01

    Roč. 7, č. 3 (2010), s. 245-251 ISSN 1214-9705 R&D Projects: GA MŠk(CZ) LC506; GA ČR GA205/08/0908 Institutional research plan: CEZ:AV0Z10030501 Keywords : Earth orientation * astrometry * reference systems Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 0.452, year: 2010 http://www.irsm.cas.cz

  8. A validated high-performance liquid chromatography method with diode array detection for simultaneous determination of nine flavonoids in Senecio cannabifolius Less.

    Science.gov (United States)

    Niu, Tian-Zeng; Zhang, Yu-Wei; Bao, Yong-Li; Wu, Yin; Yu, Chun-Lei; Sun, Lu-Guo; Yi, Jing-Wen; Huang, Yan-Xin; Li, Yu-Xin

    2013-03-25

    A reversed phase high performance liquid chromatography method coupled with a diode array detector (HPLC-DAD) was developed for the first time for the simultaneous determination of 9 flavonoids in Senecio cannabifolius, a traditional Chinese medicinal herb. Agilent Zorbax SB-C18 column was used at room temperature and the mobile phase was a mixture of acetonitrile and 0.5% formic acid (v/v) in water in the gradient elution mode at a flow-rate of 1.0mlmin(-1), detected at 360nm. Validation of this method was performed to verify the linearity, precision, limits of detection and quantification, intra- and inter-day variabilities, reproducibility and recovery. The calibration curves showed good linearities (R(2)>0.9995) within the test ranges. The relative standard deviation (RSD) of the method was less than 3.0% for intra- and inter-day assays. The samples were stable for at least 96h, and the average recoveries were between 90.6% and 102.5%. High sensitivity was demonstrated with detection limits of 0.028-0.085μg/ml for flavonoids. The newly established HPLC method represents a powerful technique for the quality assurance of S. cannabifolius. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. The Sheath-less Planar Langmuir Probe

    Science.gov (United States)

    Cooke, D. L.

    2017-12-01

    The Langmuir probe is one of the oldest plasma diagnostics, provided the plasma density and species temperature from analysis of a current-voltage curve as the voltage is swept over a practically chosen range. The analysis depends on a knowledge or theory of the many factors that influence the current-voltage curve including, probe shape, size, nearby perturbations, and the voltage reference. For applications in Low Earth Orbit, the Planar Langmuir Probe, PLP, is an attractive geometry because the ram ion current is very constant over many Volts of a sweep, allowing the ion density and electron temperature to be determined independently with the same instrument, at different points on the sweep. However, when the physical voltage reference is itself small and electrically floating as with a small spacecraft, the spacecraft and probe system become a double probe where the current collection theory depends on the interaction of the spacecraft with the plasma which is generally not as simple as the probe itself. The Sheath-less PLP, SPLP, interlaces on a single ram facing surface, two variably biased probe elements, broken into many small and intertwined segments on a scale smaller than the plasma Debye length. The SPLP is electrically isolated from the rest of the spacecraft. For relative bias potentials of a few volts, the ion current to all segments of each element will be constant, while the electron currents will vary as a function of the element potential and the electron temperature. Because the segments are small, intertwined, and floating, the assembly will always present the same floating potential to the plasma, with minimal growth as a function of voltage, thus sheath-less and still planar. This concept has been modelled with Nascap, and tested with a physical model inserted into a Low Earth Orbit-like chamber plasma. Results will be presented.

  10. ASTM reference radiologic digital image standards

    International Nuclear Information System (INIS)

    Wysnewski, R.; Wysnewski, D.

    1996-01-01

    ASTM Reference Radiographs have been essential in defining industry's material defect grade levels for many years. ASTM Reference Radiographs are used extensively as even the American Society for Metals Nondestructive Inspection and Quality Control Metals Handbook, Volume 11, eighth edition refers to ASTM Standard Reference Radiographs. The recently published E 1648 Standard Reference Radiographs for Examination of Aluminum Fusion Welds is a prime example of the on-going need for these references. To date, 14 Standard Reference Radiographs have been published to characterize material defects. Standard Reference Radiographs do not adequately address film-less radiologic methods. There are differences in mediums to content with. On a computer CRT defect indications appear differently when compared to indications viewed in a radiograph on a view box. Industry that uses non-film radiologic methods of inspection can be burdened with additional time and money developing internal standard reference radiologic images. These references may be deemed necessary for grading levels of product defects. Because there are no ASTM Standard Reference Radiologic data files for addressing this need in the industry, the authors of this paper suggested implementing a method for their creation under ASTM supervision. ASTM can assure continuity to those users making the transition from analog radiographic images to digital image data by swiftly addressing the requirements for reference digital image standards. The current status and possible future activities regarding a method to create digital data files is presented in this paper summary

  11. Demonstrated Wavelength Portability of Raman Reference Data for Explosives and Chemical Detection

    Directory of Open Access Journals (Sweden)

    Timothy J. Johnson

    2012-01-01

    Full Text Available As Raman spectroscopy continues to evolve, questions arise as to the portability of Raman data: dispersive versus Fourier transform, wavelength calibration, intensity calibration, and in particular the frequency of the excitation laser. While concerns about fluorescence arise in the visible or ultraviolet, most modern (portable systems use near-infrared excitation lasers, and many of these are relatively close in wavelength. We have investigated the possibility of porting reference data sets from one NIR wavelength system to another: We have constructed a reference library consisting of 145 spectra, including 20 explosives, as well as sundry other compounds and materials using a 1064 nm spectrometer. These data were used as a reference library to evaluate the same 145 compounds whose experimental spectra were recorded using a second 785 nm spectrometer. In 128 cases of 145 (or 88.3% including 20/20 for the explosives, the compounds were correctly identified with a mean “hit score” of 954 of 1000. Adding in criteria for when to declare a correct match versus when to declare uncertainty, the approach was able to correctly categorize 134 out of 145 spectra, giving a 92.4% accuracy. For the few that were incorrectly identified, either the matched spectra were spectroscopically similar to the target or the 785 nm signal was degraded due to fluorescence. The results indicate that imported data recorded at a different NIR wavelength can be successfully used as reference libraries, but key issues must be addressed: the reference data must be of equal or higher resolution than the resolution of the current sensor, the systems require rigorous wavelength calibration, and wavelength-dependent intensity response should be accounted for in the different systems.

  12. LESS SKILLED READERS HAVE LESS EFFICIENT SUPPRESSION MECHANISMS.

    Science.gov (United States)

    Gernsbacher, Morton Ann

    1993-09-01

    One approach to understanding the component processes and mechanisms underlying adult reading skill is to compare the performance of more skilled and less skilled readers on laboratory experiments. The results of some recent experiments employing this approach demonstrate that less skilled adult readers suppress less efficiently the inappropriate meanings of ambiguous words (e.g., the playing card vs. garden tool meanings of spade ), the incorrect forms of homophones (e.g., patients vs. patience ), the typical-but-absent members of scenes (e.g., a tractor in a farm scene), and words superimposed on pictures. Less skilled readers are not less efficient in activating contextually appropriate information; in fact, they activate contextually appropriate information more strongly than more skilled readers do. Therefore, one conclusion that can be drawn from these experiments is that less skilled adult readers suffer from less efficient suppression mechanisms.

  13. Reference in English-Arabic Translation

    DEFF Research Database (Denmark)

    Ehrensvärd, Martin Gustaf

    2007-01-01

    have an indefinite NP (less explicit) where the other has a definite NP (more explicit). But are these differences in any way systematic? In an article in Babel, Yowell Y. Aziz shows that remarkable differences obtain in the explicitness of various referring expressions when an Arabic text is compared...... with the culture. As a preliminary test of this option, the article compares the explicitness of the referring expressions in an American novel, Sula by Toni Morrison, and its Arabic translation, and in this way the article applies Aziz’ method, but instead of going from Arabic to English like Aziz, it goes...

  14. Roadside Tracker Portal-less Portal Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Ziock, Klaus-Peter [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cheriyadat, Anil M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bradley, Eric Craig [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cunningham, Mark F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Fabris, Lorenzo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Goddard, Jr, James Samuel [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hornback, Donald Eric [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Karnowski, Thomas Paul [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kerekes, Ryan A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Newby, Jason [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2013-07-01

    This report documents the full development cycle of the Roadside Tracker (RST) Portal-less Portal monitor (Fig. 1) funded by DHS DNDO. The project started with development of a proof-of-feasibility proto-type, proceeded through design and construction of a proof-of-concept (POC) prototype, a test-and-evaluation phase, participation in a Limited Use Exercise that included the Standoff Radiation Detections Systems developed under an Advanced Technology Demonstration and concluded with participation in a Characterization Study conducted by DNDO.

  15. Quality of hospital care for seriously ill children in less-developed countries

    NARCIS (Netherlands)

    Nolan, T; Angos, P; Cunha, AJLA; Muhe, L; Qazi, S; Simoes, EAF; Tamburlini, G; Weber, M; Pierce, NF

    2001-01-01

    Background improving the quality of care for sick children referred to hospitals in less-developed countries may lead to better outcomes, including reduced mortality. Data are lacking, however, on the quality of priority screening (triage), emergency care, diagnosis, and inpatient treatment in these

  16. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference.

    Science.gov (United States)

    Yamada, Yoshitake; Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Abe, Takayuki; Kuribayashi, Sachio; Ogawa, Kenji

    2013-08-01

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA-950) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA-950. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA-950. • Tomosynthesis showed significantly better diagnostic performance for pulmonary emphysema than radiography. • Interobserver agreement for tomosynthesis was significantly higher than that for radiography. • Sensitivity increased with increasing LAA -950 in both tomosynthesis and radiography. • Tomosynthesis imparts a similar radiation dose to two projection chest radiography. • Radiation dose and cost of tomosynthesis are lower than those of MDCT.

  17. Gas sensor with multiple internal reference electrodes and sensing electrodes

    DEFF Research Database (Denmark)

    2016-01-01

    The invention relates to a potentiometric gas sensor, or potentiometric gas detection element, with multiple internal reference electrodes and multiple sensing electrodes for determining the concentrations of gas components in a gaseous mixture. The sensor for gas detection comprises: a solid...

  18. Selection of appropriate reference genes for the detection of rhythmic gene expression via quantitative real-time PCR in Tibetan hulless barley.

    Directory of Open Access Journals (Sweden)

    Jing Cai

    Full Text Available Hulless barley (Hordeum vulgare L. var. nudum. hook. f. has been cultivated as a major crop in the Qinghai-Tibet plateau of China for thousands of years. Compared to other cereal crops, the Tibetan hulless barley has developed stronger endogenous resistances to survive in the severe environment of its habitat. To understand the unique resistant mechanisms of this plant, detailed genetic studies need to be performed. The quantitative real-time reverse transcription-polymerase chain reaction (qRT-PCR is the most commonly used method in detecting gene expression. However, the selection of stable reference genes under limited experimental conditions was considered to be an essential step for obtaining accurate results in qRT-PCR. In this study, 10 candidate reference genes-ACT (Actin, E2 (Ubiquitin conjugating enzyme 2, TUBα (Alpha-tubulin, TUBβ6 (Beta-tubulin 6, GAPDH (Glyceraldehyde 3-phosphate dehydrogenase, EF-1α (Elongation factor 1-alpha, SAMDC (S-adenosylmethionine decarboxylase, PKABA1 (Gene for protein kinase HvPKABA1, PGK (Phosphoglycerate kinase, and HSP90 (Heat shock protein 90-were selected from the NCBI gene database of barley. Following qRT-PCR amplifications of all candidate reference genes in Tibetan hulless barley seedlings under various stressed conditions, the stabilities of these candidates were analyzed by three individual software packages including geNorm, NormFinder, and BestKeeper. The results demonstrated that TUBβ6, E2, TUBα, and HSP90 were generally the most suitable sets under all tested conditions; similarly, TUBα and HSP90 showed peak stability under salt stress, TUBα and EF-1α were the most suitable reference genes under cold stress, and ACT and E2 were the most stable under drought stress. Finally, a known circadian gene CCA1 was used to verify the service ability of chosen reference genes. The results confirmed that all recommended reference genes by the three software were suitable for gene expression

  19. Selection of appropriate reference genes for the detection of rhythmic gene expression via quantitative real-time PCR in Tibetan hulless barley.

    Science.gov (United States)

    Cai, Jing; Li, Pengfei; Luo, Xiao; Chang, Tianliang; Li, Jiaxing; Zhao, Yuwei; Xu, Yao

    2018-01-01

    Hulless barley (Hordeum vulgare L. var. nudum. hook. f.) has been cultivated as a major crop in the Qinghai-Tibet plateau of China for thousands of years. Compared to other cereal crops, the Tibetan hulless barley has developed stronger endogenous resistances to survive in the severe environment of its habitat. To understand the unique resistant mechanisms of this plant, detailed genetic studies need to be performed. The quantitative real-time reverse transcription-polymerase chain reaction (qRT-PCR) is the most commonly used method in detecting gene expression. However, the selection of stable reference genes under limited experimental conditions was considered to be an essential step for obtaining accurate results in qRT-PCR. In this study, 10 candidate reference genes-ACT (Actin), E2 (Ubiquitin conjugating enzyme 2), TUBα (Alpha-tubulin), TUBβ6 (Beta-tubulin 6), GAPDH (Glyceraldehyde 3-phosphate dehydrogenase), EF-1α (Elongation factor 1-alpha), SAMDC (S-adenosylmethionine decarboxylase), PKABA1 (Gene for protein kinase HvPKABA1), PGK (Phosphoglycerate kinase), and HSP90 (Heat shock protein 90)-were selected from the NCBI gene database of barley. Following qRT-PCR amplifications of all candidate reference genes in Tibetan hulless barley seedlings under various stressed conditions, the stabilities of these candidates were analyzed by three individual software packages including geNorm, NormFinder, and BestKeeper. The results demonstrated that TUBβ6, E2, TUBα, and HSP90 were generally the most suitable sets under all tested conditions; similarly, TUBα and HSP90 showed peak stability under salt stress, TUBα and EF-1α were the most suitable reference genes under cold stress, and ACT and E2 were the most stable under drought stress. Finally, a known circadian gene CCA1 was used to verify the service ability of chosen reference genes. The results confirmed that all recommended reference genes by the three software were suitable for gene expression analysis

  20. THE MASS OF HD 38529c FROM HUBBLE SPACE TELESCOPE ASTROMETRY AND HIGH-PRECISION RADIAL VELOCITIES

    International Nuclear Information System (INIS)

    Benedict, G. Fritz; McArthur, Barbara E.; Bean, Jacob L.; Barnes, Rory; Harrison, Thomas E.; Hatzes, Artie; Martioli, Eder; Nelan, Edmund P.

    2010-01-01

    Hubble Space Telescope Fine Guidance Sensor astrometric observations of the G4 IV star HD 38529 are combined with the results of the analysis of extensive ground-based radial velocity (RV) data to determine the mass of the outermost of two previously known companions. Our new RVs obtained with the Hobby-Eberly Telescope and velocities from the Carnegie-California group now span over 11 yr. With these data we obtain improved RV orbital elements for both the inner companion, HD 38529b, and the outer companion, HD 38529c. We identify a rotational period of HD 38529 (P rot = 31.65 ± 0fd17) with Fine Guidance Sensor photometry. The inferred star spot fraction is consistent with the remaining scatter in velocities being caused by spot-related stellar activity. We then model the combined astrometric and RV measurements to obtain the parallax, proper motion, perturbation period, perturbation inclination, and perturbation size due to HD 38529c. For HD 38529c we find P = 2136.1 ± 0.3 d, perturbation semimajor axis α = 1.05 ± 0.06 mas, and inclination i = 48. 0 3 ± 3. 0 7. Assuming a primary mass M * = 1.48 M sun , we obtain a companion mass M c = 17.6 +1.5 -1.2 M Jup , 3σ above a 13 M Jup deuterium burning, brown dwarf lower limit. Dynamical simulations incorporating this accurate mass for HD 38529c indicate that a near-Saturn mass planet could exist between the two known companions. We find weak evidence of an additional low amplitude signal that can be modeled as a planetary-mass (∼0.17 M Jup ) companion at P ∼194 days. Including this component in our modeling lowers the error of the mass determined for HD 38529c. Additional observations (RVs and/or Gaia astrometry) are required to validate an interpretation of HD 38529d as a planetary-mass companion. If confirmed, the resulting HD 38529 planetary system may be an example of a 'Packed Planetary System'.

  1. True Detective

    OpenAIRE

    Gajhede, Andreas; Westmark, [No Value; Bantoulidis, Georgios

    2016-01-01

    This paper examines the HBO’s television-series True Detective, a 2014 crime drama, attempting to point out the central elements of detective-fiction, to be found in its narrative. True Detective narrative is a heavy text with a number of references from various well-known, non-adjacent texts within the field of weird fiction, horror fiction and detective fiction. Therefore, the case study of this research will focus on narratological and literary analysis, in order to discover the predominan...

  2. Diagnostic performance of dental students in identifying mandibular condyle fractures by panoramic radiography and the usefulness of reference images

    International Nuclear Information System (INIS)

    Cho, Bong Hae

    2011-01-01

    The purpose of this study was to evaluate the diagnostic performance of dental students in detection of mandibular condyle fractures and the effectiveness of reference panoramic images. Forty-six undergraduates evaluated 25 panoramic radiographs for condylar fractures and the data were analyzed through receiver operating characteristic (ROC) analysis. After a month, they were divided into two homogeneous groups based on the first results and re-evaluated the images with (group A) or without (group B) reference images. Eight reference images included indications showing either typical condylar fractures or anatomic structures which could be confused with fractures. Paired t-test was used for statistical analysis of the difference between the first and the second evaluations for each group, and student's t-test was used between the two groups in the second evaluation. The intra- and inter-observer agreements were evaluated with Kappa statistics. Intra- and inter-observer agreements were substantial (k=0.66) and moderate (k=0.53), respectively. The area under the ROC curve (Az) in the first evaluation was 0.802. In the second evaluation, it was increased to 0.823 for group A and 0.814 for group B. The difference between the first and second evaluations for group A was statistically significant (p<0.05), however there was no statistically significant difference between the two groups in the second evaluation. Providing reference images to less experienced clinicians would be a good way to improve the diagnostic ability in detecting condylar fracture.

  3. Diagnostic performance of dental students in identifying mandibular condyle fractures by panoramic radiography and the usefulness of reference images

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Bong Hae [School of Dentistry, Pusan National University, Pusan (Korea, Republic of)

    2011-06-15

    The purpose of this study was to evaluate the diagnostic performance of dental students in detection of mandibular condyle fractures and the effectiveness of reference panoramic images. Forty-six undergraduates evaluated 25 panoramic radiographs for condylar fractures and the data were analyzed through receiver operating characteristic (ROC) analysis. After a month, they were divided into two homogeneous groups based on the first results and re-evaluated the images with (group A) or without (group B) reference images. Eight reference images included indications showing either typical condylar fractures or anatomic structures which could be confused with fractures. Paired t-test was used for statistical analysis of the difference between the first and the second evaluations for each group, and student's t-test was used between the two groups in the second evaluation. The intra- and inter-observer agreements were evaluated with Kappa statistics. Intra- and inter-observer agreements were substantial (k=0.66) and moderate (k=0.53), respectively. The area under the ROC curve (Az) in the first evaluation was 0.802. In the second evaluation, it was increased to 0.823 for group A and 0.814 for group B. The difference between the first and second evaluations for group A was statistically significant (p<0.05), however there was no statistically significant difference between the two groups in the second evaluation. Providing reference images to less experienced clinicians would be a good way to improve the diagnostic ability in detecting condylar fracture.

  4. A clinical study for radiotherapy positioning with references images on CT simulator

    International Nuclear Information System (INIS)

    Yang Bo; Sun Xiaoyang; Luo Huiqun; Wu Hong; Pang Haowen

    2011-01-01

    Objective: To explore a new method of comparing the references images first to enhance the precision of the central point of the radiation treatment planning (RTP), try to establish a reference standard for this method in the nasopharyngeal cancer (NPC) and carcinoma of utercin cervix in the work of position verification. Methods: For 50 RTPs of NPC and 20 RTPs of carcinoma of utercin cervix, the reference-CT-images in set-up and in position verification were compared, and to measure the difference between the two images. Then, in the same way, compare and measure the difference in the central-point-images. Results: For NPC, there was over 90% RTPs in which every difference measured was less than 2 mm;for carcinoma of utercin cervix, over 80% RTPs meet the criterion:the value of ΔMU 1 ' or ΔMU 2 ' was less than 5 mm and the others are less than 3 mm. Conclusions: By comparing the references-CT-images in set-up and in position verification, the precision of the central point of the RTP is enhanced. The marks on the skin become more credible. So, it is feasible to perform the criterions in the work of position verification: for NPC every difference measured is less than 2 mm; for carcinoma of utercin cervix the value of ΔMU 1 ' or ΔMU 2 ' is less than 5 mm and the others are less than 3 mm. (authors)

  5. New Normative Database of Inner Macular Layer Thickness Measured by Spectralis OCT Used as Reference Standard for Glaucoma Detection.

    Science.gov (United States)

    Nieves-Moreno, María; Martínez-de-la-Casa, José M; Bambo, María P; Morales-Fernández, Laura; Van Keer, Karel; Vandewalle, Evelien; Stalmans, Ingeborg; García-Feijoó, Julián

    2018-02-01

    This study examines the capacity to detect glaucoma of inner macular layer thickness measured by spectral-domain optical coherence tomography (SD-OCT) using a new normative database as the reference standard. Participants ( N = 148) were recruited from Leuven (Belgium) and Zaragoza (Spain): 74 patients with early/moderate glaucoma and 74 age-matched healthy controls. One eye was randomly selected for a macular scan using the Spectralis SD-OCT. The variables measured with the instrument's segmentation software were: macular nerve fiber layer (mRNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL) volume and thickness along with circumpapillary RNFL thickness (cpRNFL). The new normative database of macular variables was used to define the cutoff of normality as the fifth percentile by age group. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) of each macular measurement and of cpRNFL were used to distinguish between patients and controls. Overall sensitivity and specificity to detect early-moderate glaucoma were 42.2% and 88.9% for mRNFL, 42.4% and 95.6% for GCL, 42.2% and 94.5% for IPL, and 53% and 94.6% for RNFL, respectively. The best macular variable to discriminate between the two groups of subjects was outer temporal GCL thickness as indicated by an AUROC of 0.903. This variable performed similarly to mean cpRNFL thickness (AUROC = 0.845; P = 0.29). Using our normative database as reference, the diagnostic power of inner macular layer thickness proved comparable to that of peripapillary RNFL thickness. Spectralis SD-OCT, cpRNFL thickness, and individual macular inner layer thicknesses show comparable diagnostic capacity for glaucoma and RNFL, GCL, and IPL thickness may be useful as an alternative diagnostic test when the measure of cpRNFL shows artifacts.

  6. Electronic cigarette aerosol induces significantly less cytotoxicity than tobacco smoke

    Science.gov (United States)

    Azzopardi, David; Patel, Kharishma; Jaunky, Tomasz; Santopietro, Simone; Camacho, Oscar M.; McAughey, John; Gaça, Marianna

    2016-01-01

    Abstract Electronic cigarettes (E-cigarettes) are a potential means of addressing the harm to public health caused by tobacco smoking by offering smokers a less harmful means of receiving nicotine. As e-cigarettes are a relatively new phenomenon, there are limited scientific data on the longer-term health effects of their use. This study describes a robust in vitro method for assessing the cytotoxic response of e-cigarette aerosols that can be effectively compared with conventional cigarette smoke. This was measured using the regulatory accepted Neutral Red Uptake assay modified for air–liquid interface (ALI) exposures. An exposure system, comprising a smoking machine, traditionally used for in vitro tobacco smoke exposure assessments, was adapted for use with e-cigarettes to expose human lung epithelial cells at the ALI. Dosimetric analysis methods using real-time quartz crystal microbalances for mass, and post-exposure chemical analysis for nicotine, were employed to detect/distinguish aerosol dilutions from a reference Kentucky 3R4F cigarette and two commercially available e-cigarettes (Vype eStick and ePen). ePen aerosol induced 97%, 94% and 70% less cytotoxicity than 3R4F cigarette smoke based on matched EC50 values at different dilutions (1:5 vs. 1:153 vol:vol), mass (52.1 vs. 3.1 μg/cm2) and nicotine (0.89 vs. 0.27 μg/cm2), respectively. Test doses where cigarette smoke and e-cigarette aerosol cytotoxicity were observed are comparable with calculated daily doses in consumers. Such experiments could form the basis of a larger package of work including chemical analyses, in vitro toxicology tests and clinical studies, to help assess the safety of current and next generation nicotine and tobacco products. PMID:27690199

  7. Valores de referência para carboxiemoglobina Reference values for carboxyhemoglobin

    Directory of Open Access Journals (Sweden)

    Maria Elisa P. B. de Siqueira

    1997-12-01

    the present study, the RV for carboxyhemoglobin (COHb was determined for the South of Minas Gerais. MATERIAL AND METHOD: The COHb was analyzed by the Beutler and West (1984 spectrophotometric method, optimized in our laboratory. In all the samples, analyses of some biochemical and hematological parameters were made to evaluate the health condition of a population of 200 volunteer non-smokers occupationally not exposed to CO. Each individual answered a questionnaire to obtain data pertinent to the interpretation of the results. The reference values were expressed as mean values ± standard deviation, with a 95% confidence interval, and an upper reference value. The statistical distribution of the results was made so as to enable comparisons between the results of groups of workers, rather than individual evaluations, to be made. RESULTS AND CONCLUSION: The mean value ± standard deviation was 1.0% ± 0.75; the 95% confidence interval was 0,9 - 1.1% and the upper reference value was 2.5%. By the t Student test (p < 0.05, no difference was detected between the values related to sex, age or ingestion of alcoholic beverages. The reference values obtained were close to those reported for others countries.

  8. What Determines the Response: Test or Reference?

    Science.gov (United States)

    Chukova, S. V.; Ahumada, A. J., Jr.; Null, Cynthia (Technical Monitor)

    1998-01-01

    The stability of sensory memory has been studied by presenting a reference stimulus, a delay, and a test stimulus. As has been pointed out by Lages and Treisman (1998 Vision Research 38 557-572), the usual measure of performance depends only on the effect of test variations on the responses. The Weber fraction characterizing performance is more properly called the test stimulus Weber fraction. We measure the relative contribution of the test and reference to the response by the ratio of the test Weber fraction to the reference Weber fraction. The stimuli were two dark lines on a bright background. Seven reference separations, varying from 9.5 to 16.7 arc min, were intermixed in each run. Interstimulus intervals (ISI) of 50, 200 and 2000 msec and intertrial intervals (ITI) of 500 and 2500 msec were investigated. When the ISI was short (50 or 200 msec), for both ITIs, responses were determined equally by the test and reference. For the long ISI (2000 msec), the reference stimulus contributed less. However, only for the 500 msec ITI (and not for all observers) was the contribution of the reference stimulus negligible, as Treisman's criterion setting theory might suggest.

  9. Reference hydrologic networks I. The status and potential future directions of national reference hydrologic networks for detecting trends

    Science.gov (United States)

    Whitfield, Paul H.; Burn, Donald H.; Hannaford, Jamie; Higgins, Hélène; Hodgkins, Glenn A.; Marsh, Terry; Looser, Ulrich

    2012-01-01

    Identifying climate-driven trends in river flows on a global basis is hampered by a lack of long, quality time series data for rivers with relatively undisturbed regimes. This is a global problem compounded by the lack of support for essential long-term monitoring. Experience demonstrates that, with clear strategic objectives, and the support of sponsoring organizations, reference hydrologic networks can constitute an exceptionally valuable data source to effectively identify, quantify and interpret hydrological change—the speed and magnitude of which is expected to a be a primary driver of water management and flood alleviation strategies through the future—and for additional applications. Reference hydrologic networks have been developed in many countries in the past few decades. These collections of streamflow gauging stations, that are maintained and operated with the intention of observing how the hydrology of watersheds responds to variations in climate, are described. The status of networks under development is summarized. We suggest a plan of actions to make more effective use of this collection of networks.

  10. Gaia and exoplanets: a revolution in the making

    Science.gov (United States)

    Sozzetti, Alessandro

    2017-09-01

    The Gaia global astrometry mission is now entering its fourth year of routine science operations. With the publication of the first data release in September 2016, it has begun to fulfil its promise for revolutionary science in countless aspects of Galactic astronomy and astrophysics. I briefly review the Gaia mission status of operations and the scenario for the upcoming intermediate data releases, focusing on important lessons learned. Then, I illustrate the Gaia exoplanet science case, and discuss how the field will be revolutionized by the power of microarcsecond (μas) astrometry that is about to be unleashed. I conclude by touching upon some of the synergy elements that will call for combination of Gaia data with other indirect and direct detection and characterization techniques, for much improved understanding of exoplanetary systems.

  11. The epidural expansion in the waist canal - less obvious findings

    International Nuclear Information System (INIS)

    Nekula, J.; Bucil, J.; Burval, S.

    1998-01-01

    The authors demonstrated 55 less obvious epidural expansion in the waist canal. These expansions are discussed. The detection of the epidural mass at myeloma multiples has a principal significance for the indication of the radiotherapy or surgical intervention

  12. Gaia DR2 documentation Chapter 3: Astrometry

    Science.gov (United States)

    Hobbs, D.; Lindegren, L.; Bastian, U.; Klioner, S.; Butkevich, A.; Stephenson, C.; Hernandez, J.; Lammers, U.; Bombrun, A.; Mignard, F.; Altmann, M.; Davidson, M.; de Bruijne, J. H. J.; Fernández-Hernández, J.; Siddiqui, H.; Utrilla Molina, E.

    2018-04-01

    This chapter of the Gaia DR2 documentation describes the models and processing steps used for the astrometric core solution, namely, the Astrometric Global Iterative Solution (AGIS). The inputs to this solution rely heavily on the basic observables (or astrometric elementaries) which have been pre-processed and discussed in Chapter 2, the results of which were published in Fabricius et al. (2016). The models consist of reference systems and time scales; assumed linear stellar motion and relativistic light deflection; in addition to fundamental constants and the transformation of coordinate systems. Higher level inputs such as: planetary and solar system ephemeris; Gaia tracking and orbit information; initial quasar catalogues and BAM data are all needed for the processing described here. The astrometric calibration models are outlined followed by the details processing steps which give AGIS its name. We also present a basic quality assessment and validation of the scientific results (for details, see Lindegren et al. 2018).

  13. Reference handbook: Level detectors

    International Nuclear Information System (INIS)

    1990-01-01

    The purpose of this handbook is to provide Rocky Flats personnel with the information necessary to understand level measurement and detection. Upon completion of this handbook you should be able to do the following: List three reasons for measuring level. Describe the basic operating principles of the sight glass. Demonstrate proper techniques for reading a sight glass. Describe the basic operating principles of a float level detector. Describe the basic operating principles of a bubbler level indicating system. Explain the differences between a wet and dry reference leg indicating system, and describe how each functions. This handbook is designed for use by experienced Rocky Flats operators to reinforce and improve their current knowledge level, and by entry-level operators to ensure that they possess a minimum level of fundamental knowledge. Level Detectors is applicable to many job classifications and can be used as a reference for classroom work or for self-study. Although this reference handbook is by no means all-encompassing, you will gain enough information about this subject area to assist you in contributing to the safe operation of Rocky Flats Plant

  14. A framework to protect mobile agents by using reference states

    OpenAIRE

    Hohl, Fritz

    2000-01-01

    To protect mobile agents from attacks by their execution environments, or hosts, one class of protection mechanisms uses 'reference states' to detect modification attacks. Reference states are agent states that have been produced by non-attacking, or reference hosts. This paper examines this class of mechanisms and present the bandwidth of the achieved protection. First, a new general definition of attacks against mobile agents is presented. As this general definition does not lead to a pract...

  15. LESS SKILLED READERS HAVE LESS EFFICIENT SUPPRESSION MECHANISMS

    OpenAIRE

    Gernsbacher, Morton Ann

    1993-01-01

    One approach to understanding the component processes and mechanisms underlying adult reading skill is to compare the performance of more skilled and less skilled readers on laboratory experiments. The results of some recent experiments employing this approach demonstrate that less skilled adult readers suppress less efficiently the inappropriate meanings of ambiguous words (e.g., the playing card vs. garden tool meanings of spade), the incorrect forms of homophones (e.g., patients vs. patien...

  16. Compensated intruder-detection systems

    Science.gov (United States)

    McNeilly, David R.; Miller, William R.

    1984-01-01

    Intruder-detection systems in which intruder-induced signals are transmitted through a medium also receive spurious signals induced by changes in a climatic condition affecting the medium. To combat this, signals received from the detection medium are converted to a first signal. The system also provides a reference signal proportional to climate-induced changes in the medium. The first signal and the reference signal are combined for generating therefrom an output signal which is insensitive to the climatic changes in the medium. An alarm is energized if the output signal exceeds a preselected value. In one embodiment, an acoustic cable is coupled to a fence to generate a first electrical signal proportional to movements thereof. False alarms resulting from wind-induced movements of the fence (detection medium) are eliminated by providing an anemometer-driven voltage generator to provide a reference voltage proportional to the velocity of wind incident on the fence. An analog divider receives the first electrical signal and the reference signal as its numerator and denominator inputs, respectively, and generates therefrom an output signal which is insensitive to the wind-induced movements in the fence.

  17. Teaching students about informatics and astronomy using real data for detection of asteroids

    Science.gov (United States)

    Boldea, A. L.; Vaduvescu, O.

    2017-09-01

    In this paper we approach the astronomy teaching process for students in computer sciences through a controlled investigation method using real astronomical data, including data reduction and quality control of the astrometry of near-Earth asteroids. The method used data collected on the Isaac Newton Telescope located at the ORM observatory on the island of La Palma in the Spanish Canary Islands and was successfully tested with a group of students in their second year of study.

  18. Rapid detection of multidrug-resistant Mycobacterium tuberculosis using the malachite green decolourisation assay

    Science.gov (United States)

    Coban, Ahmet Yilmaz; Uzun, Meltem

    2013-01-01

    Early detection of drug resistance in Mycobacterium tuberculosis isolates allows for earlier and more effective treatment of patients. The aim of this study was to investigate the performance of the malachite green decolourisation assay (MGDA) in detecting isoniazid (INH) and rifampicin (RIF) resistance in M. tuberculosis clinical isolates. Fifty M. tuberculosis isolates, including 19 multidrug-resistant, eight INH-resistant and 23 INH and RIF-susceptible samples, were tested. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and agreement of the assay for INH were 92.5%, 91.3%, 92.5%, 91.3% and 92%, respectively. Similarly, the sensitivity, specificity, PPV, NPV and agreement of the assay for RIF were 94.7%, 100%, 100%, 96.8% and 98%, respectively. There was a major discrepancy in the tests of two isolates, as they were sensitive to INH by the MGDA test, but resistant by the reference method. There was a minor discrepancy in the tests of two additional isolates, as they were sensitive to INH by the reference method, but resistant by the MGDA test. The drug susceptibility test results were obtained within eight-nine days. In conclusion, the MGDA test is a reliable and accurate method for the rapid detection of INH and RIF resistance compared with the reference method and the MGDA test additionally requires less time to obtain results. PMID:24402143

  19. Rapid detection of multidrug-resistant Mycobacterium tuberculosis using the malachite green decolourisation assay

    Directory of Open Access Journals (Sweden)

    Ahmet Yilmaz Coban

    2013-12-01

    Full Text Available Early detection of drug resistance in Mycobacterium tuberculosis isolates allows for earlier and more effective treatment of patients. The aim of this study was to investigate the performance of the malachite green decolourisation assay (MGDA in detecting isoniazid (INH and rifampicin (RIF resistance in M. tuberculosis clinical isolates. Fifty M. tuberculosis isolates, including 19 multidrug-resistant, eight INH-resistant and 23 INH and RIF-susceptible samples, were tested. The sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV and agreement of the assay for INH were 92.5%, 91.3%, 92.5%, 91.3% and 92%, respectively. Similarly, the sensitivity, specificity, PPV, NPV and agreement of the assay for RIF were 94.7%, 100%, 100%, 96.8% and 98%, respectively. There was a major discrepancy in the tests of two isolates, as they were sensitive to INH by the MGDA test, but resistant by the reference method. There was a minor discrepancy in the tests of two additional isolates, as they were sensitive to INH by the reference method, but resistant by the MGDA test. The drug susceptibility test results were obtained within eight-nine days. In conclusion, the MGDA test is a reliable and accurate method for the rapid detection of INH and RIF resistance compared with the reference method and the MGDA test additionally requires less time to obtain results.

  20. Reference in English-Arabic Translation

    DEFF Research Database (Denmark)

    Ehrensvärd, Martin

    2008-01-01

    The use of referring expressions (proper nouns, noun phrases [NPs] and pronouns) in a target language [TL] text may differ from the source language [SL] text with regard to how explicit they are: One may have a pronoun (less explicit) where the other has a proper noun (more explicit), or one may...... of the text? The last option would make good sense. The SL text is written for an audience who knows the language and hence is expected to be more or less familiar with the culture. Therefore the author may not need to be as explicit as he or she would be if writing for an audience not so familiar...

  1. Reference in English-Arabic Translation

    DEFF Research Database (Denmark)

    Ehrensvärd, Martin Gustaf

    2007-01-01

    The use of referring expressions (proper nouns, noun phrases [NPs] and pronouns) in a target language [TL] text may differ from the source language [SL] text with regard to how explicit they are: One may have a pronoun (less explicit) where the other has a proper noun (more explicit), or one may...... of the text? The last option would make good sense. The SL text is written for an audience who knows the language and hence is expected to be more or less familiar with the culture. Therefore the author may not need to be as explicit as he or she would be if writing for an audience not so familiar...

  2. Comparison of pulsar positions from timing and very long baseline astrometry

    Science.gov (United States)

    Wang, J. B.; Coles, W. A.; Hobbs, G.; Shannon, R. M.; Manchester, R. N.; Kerr, M.; Yuan, J. P.; Wang, N.; Bailes, M.; Bhat, N. D. R.; Dai, S.; Dempsey, J.; Keith, M. J.; Lasky, P. D.; Levin, Y.; Osłowski, S.; Ravi, V.; Reardon, D. J.; Rosado, P. A.; Russell, C. J.; Spiewak, R.; van Straten, W.; Toomey, L.; Wen, L.; You, X.-P.; Zhu, X.-J.

    2017-07-01

    Pulsar positions can be measured with high precision using both pulsar timing methods and very long baseline interferometry (VLBI). Pulsar timing positions are referenced to a solar-system ephemeris, whereas VLBI positions are referenced to distant quasars. Here, we compare pulsar positions from published VLBI measurements with those obtained from pulsar timing data from the Nanshan and Parkes radio telescopes in order to relate the two reference frames. We find that the timing positions differ significantly from the VLBI positions (and also differ between different ephemerides). A statistically significant change in the obliquity of the ecliptic of 2.16 ± 0.33 mas is found for the JPL ephemeris DE405, but no significant rotation is found in subsequent JPL ephemerides. The accuracy with which we can relate the two frames is limited by the current uncertainties in the VLBI reference source positions and in matching the pulsars to their reference source. Not only do the timing positions depend on the ephemeris used in computing them, but also different segments of the timing data lead to varying position estimates. These variations are mostly common to all ephemerides, but slight changes are seen at the 10 μas level between ephemerides.

  3. Dynamic multiple thresholding breast boundary detection algorithm for mammograms

    International Nuclear Information System (INIS)

    Wu, Yi-Ta; Zhou Chuan; Chan, Heang-Ping; Paramagul, Chintana; Hadjiiski, Lubomir M.; Daly, Caroline Plowden; Douglas, Julie A.; Zhang Yiheng; Sahiner, Berkman; Shi Jiazheng; Wei Jun

    2010-01-01

    Purpose: Automated detection of breast boundary is one of the fundamental steps for computer-aided analysis of mammograms. In this study, the authors developed a new dynamic multiple thresholding based breast boundary (MTBB) detection method for digitized mammograms. Methods: A large data set of 716 screen-film mammograms (442 CC view and 274 MLO view) obtained from consecutive cases of an Institutional Review Board approved project were used. An experienced breast radiologist manually traced the breast boundary on each digitized image using a graphical interface to provide a reference standard. The initial breast boundary (MTBB-Initial) was obtained by dynamically adapting the threshold to the gray level range in local regions of the breast periphery. The initial breast boundary was then refined by using gradient information from horizontal and vertical Sobel filtering to obtain the final breast boundary (MTBB-Final). The accuracy of the breast boundary detection algorithm was evaluated by comparison with the reference standard using three performance metrics: The Hausdorff distance (HDist), the average minimum Euclidean distance (AMinDist), and the area overlap measure (AOM). Results: In comparison with the authors' previously developed gradient-based breast boundary (GBB) algorithm, it was found that 68%, 85%, and 94% of images had HDist errors less than 6 pixels (4.8 mm) for GBB, MTBB-Initial, and MTBB-Final, respectively. 89%, 90%, and 96% of images had AMinDist errors less than 1.5 pixels (1.2 mm) for GBB, MTBB-Initial, and MTBB-Final, respectively. 96%, 98%, and 99% of images had AOM values larger than 0.9 for GBB, MTBB-Initial, and MTBB-Final, respectively. The improvement by the MTBB-Final method was statistically significant for all the evaluation measures by the Wilcoxon signed rank test (p<0.0001). Conclusions: The MTBB approach that combined dynamic multiple thresholding and gradient information provided better performance than the breast boundary

  4. Very deep hole systems engineering studies. [20,000 ft or less

    Energy Technology Data Exchange (ETDEWEB)

    None

    1983-12-01

    Very Deep Hole (VDH) Waste Isolation is an alternative to or an augmentation of the mined geologic repository (MGR) for high-level radioactive waste. This planning study of the VDH concept identifies the significant problem areas associated with a VDH system, identifies and discusses attributes of the VDH concept, narrows discussions to a reference VDH system, and provides preliminary estimates of costs and schedule, and an engineering program plan for VDH system and equipment development. For the reference VDH selected for this study, the nuclear waste is emplaced and disposed in 20-in. holes that are drilled by modified rotary rigs and at depths of 20,000 feet or less. The waste is to be contained within a repository zone of the host rock having low porosity, low hydraulic gradient, and low permeability, and the repository zone is not penetrated by any aquifer. Thus, the depth of emplacement and characteristics of the host rock provide isolation that would preclude unacceptable migration of radionuclides to the biosphere. The VDH concept is credible and the reference system is technically feasible, logical, practical, and achievable by the year 2000, with slight modification of present technology. In terms of costs, the reference VDH system compares favorably with costs for MGR system disposal in salt, granite, shale, and basalt. 130 references, 39 figures, 17 tables.

  5. Development of real-time PCR method for the detection and the quantification of a new endogenous reference gene in sugar beet "Beta vulgaris L.": GMO application.

    Science.gov (United States)

    Chaouachi, Maher; Alaya, Akram; Ali, Imen Ben Haj; Hafsa, Ahmed Ben; Nabi, Nesrine; Bérard, Aurélie; Romaniuk, Marcel; Skhiri, Fethia; Saïd, Khaled

    2013-01-01

    KEY MESSAGE : Here, we describe a new developed quantitative real-time PCR method for the detection and quantification of a new specific endogenous reference gene used in GMO analysis. The key requirement of this study was the identification of a new reference gene used for the differentiation of the four genomic sections of the sugar beet (Beta vulgaris L.) (Beta, Corrollinae, Nanae and Procumbentes) suitable for quantification of genetically modified sugar beet. A specific qualitative polymerase chain reaction (PCR) assay was designed to detect the sugar beet amplifying a region of the adenylate transporter (ant) gene only from the species of the genomic section I of the genus Beta (cultivated and wild relatives) and showing negative PCR results for 7 species of the 3 other sections, 8 related species and 20 non-sugar beet plants. The sensitivity of the assay was 15 haploid genome copies (HGC). A quantitative real-time polymerase chain reaction (QRT-PCR) assay was also performed, having high linearity (R (2) > 0.994) over sugar beet standard concentrations ranging from 20,000 to 10 HGC of the sugar beet DNA per PCR. The QRT-PCR assay described in this study was specific and more sensitive for sugar beet quantification compared to the validated test previously reported in the European Reference Laboratory. This assay is suitable for GMO quantification in routine analysis from a wide variety of matrices.

  6. A qualitative study examining the experience of primary care dentists in the detection and management of potentially malignant lesions. 1. Factors influencing detection and the decision to refer.

    Science.gov (United States)

    Brocklehurst, P R; Baker, S R; Speight, P M

    2010-01-23

    Many oral squamous cell carcinomas present as late stage disease and so the detection of early and pre-malignancy is considered to be of paramount importance. The majority of research examining primary care dentists' experience of the detection and management of early disease has been undertaken using questionnaires, with the inherent bias this introduces. The aim of this study was to use qualitative methods to develop a richer account of practitioners' views about screening and what factors influence the decision to refer a patient. Semi-structured interviews were undertaken with eighteen dentists in Sheffield, transcribed and analysed using thematic analysis. Ten codes were identified according to the aims of the study and organized into four overarching themes. Although many dentists were screening regularly, some did not appear to be adopting a rigorous and systematic approach. A number of participants also placed more reliance on 'classical' presentations rather than the more varied presentation of potentially malignant lesions and were more influenced by the clinical history of the lesion rather than risk factors. Overall, the present research suggests that for some dentists, more rigour is required when examining for early disease.

  7. Bias detection and certified reference materials for random measurands

    Science.gov (United States)

    Rukhin, Andrew L.

    2015-12-01

    A problem that frequently occurs in metrology is the bias checking of data obtained by a laboratory against the specified value and uncertainty estimate given in the certificate of analysis. The measurand—a property of a certified reference material (CRM)—is supposed to be random with a normal distribution whose parameters are given by the certificate specifications. The laboratory’s data from subsequent measurements of the CRM (a CRM experiment) are summarized by the sample mean value and its uncertainty which is commonly based on a repeatability standard deviation. New confidence intervals for the lab’s bias are derived. Although they may lack intuitive appeal, those obtained by using higher order asymptotic methods, compared and contrasted in this paper, are recommended.

  8. A Reference-Free and Non-Contact Method for Detecting and Imaging Damage in Adhesive-Bonded Structures Using Air-Coupled Ultrasonic Transducers

    Directory of Open Access Journals (Sweden)

    Timotius Yonathan Sunarsa

    2017-12-01

    Full Text Available Adhesive bonded structures have been widely used in aerospace, automobile, and marine industries. Due to the complex nature of the failure mechanisms of bonded structures, cost-effective and reliable damage detection is crucial for these industries. Most of the common damage detection methods are not adequately sensitive to the presence of weakened bonding. This paper presents an experimental and analytical method for the in-situ detection of damage in adhesive-bonded structures. The method is fully non-contact, using air-coupled ultrasonic transducers (ACT for ultrasonic wave generation and sensing. The uniqueness of the proposed method relies on accurate detection and localization of weakened bonding in complex adhesive bonded structures. The specimens tested in this study are parts of real-world structures with critical and complex damage types, provided by Hyundai Heavy Industries® and IKTS Fraunhofer®. Various transmitter and receiver configurations, including through transmission, pitch-catch scanning, and probe holder angles, were attempted, and the obtained results were analyzed. The method examines the time-of-flight of the ultrasonic waves over a target inspection area, and the spatial variation of the time-of-flight information was examined to visualize and locate damage. The proposed method works without relying on reference data obtained from the pristine condition of the target specimen. Aluminum bonded plates and triplex adhesive layers with debonding and weakened bonding were used to examine the effectiveness of the method.

  9. The role of haemorrhage and exudate detection in automated grading of diabetic retinopathy.

    Science.gov (United States)

    Fleming, Alan D; Goatman, Keith A; Philip, Sam; Williams, Graeme J; Prescott, Gordon J; Scotland, Graham S; McNamee, Paul; Leese, Graham P; Wykes, William N; Sharp, Peter F; Olson, John A

    2010-06-01

    Automated grading has the potential to improve the efficiency of diabetic retinopathy screening services. While disease/no disease grading can be performed using only microaneurysm detection and image-quality assessment, automated recognition of other types of lesions may be advantageous. This study investigated whether inclusion of automated recognition of exudates and haemorrhages improves the detection of observable/referable diabetic retinopathy. Images from 1253 patients with observable/referable retinopathy and 6333 patients with non-referable retinopathy were obtained from three grading centres. All images were reference-graded, and automated disease/no disease assessments were made based on microaneurysm detection and combined microaneurysm, exudate and haemorrhage detection. Introduction of algorithms for exudates and haemorrhages resulted in a statistically significant increase in the sensitivity for detection of observable/referable retinopathy from 94.9% (95% CI 93.5 to 96.0) to 96.6% (95.4 to 97.4) without affecting manual grading workload. Automated detection of exudates and haemorrhages improved the detection of observable/referable retinopathy.

  10. Comparison of Forced-Alignment Speech Recognition and Humans for Generating Reference VAD

    DEFF Research Database (Denmark)

    Kraljevski, Ivan; Tan, Zheng-Hua; Paola Bissiri, Maria

    2015-01-01

    This present paper aims to answer the question whether forced-alignment speech recognition can be used as an alternative to humans in generating reference Voice Activity Detection (VAD) transcriptions. An investigation of the level of agreement between automatic/manual VAD transcriptions and the ......This present paper aims to answer the question whether forced-alignment speech recognition can be used as an alternative to humans in generating reference Voice Activity Detection (VAD) transcriptions. An investigation of the level of agreement between automatic/manual VAD transcriptions...... and the reference ones produced by a human expert was carried out. Thereafter, statistical analysis was employed on the automatically produced and the collected manual transcriptions. Experimental results confirmed that forced-alignment speech recognition can provide accurate and consistent VAD labels....

  11. Development and Validation of a Lateral Flow Immunoassay for Rapid Detection of NDM-Producing Enterobacteriaceae

    Science.gov (United States)

    Boutal, Hervé; Naas, Thierry; Devilliers, Karine; Oueslati, Saoussen; Bernabeu, Sandrine; Simon, Stéphanie

    2017-01-01

    ABSTRACT The global spread of carbapenemase-producing Enterobacteriaceae (CPE) that are often resistant to most, if not all, classes of antibiotics is a major public health concern. The NDM-1 carbapenemase is among the most worrisome carbapenemases given its rapid worldwide spread. We have developed and evaluated a lateral flow immunoassay (LFIA) (called the NDM LFIA) for the rapid and reliable detection of NDM-like carbapenemase-producing Enterobacteriaceae from culture colonies. We evaluated the NDM LFIA using 175 reference enterobacterial isolates with characterized β-lactamase gene content and 74 nonduplicate consecutive carbapenem-resistant clinical isolates referred for expertise to the French National Reference Center (NRC) for Antibiotic Resistance during a 1-week period (in June 2016). The reference collection included 55 non-carbapenemase producers and 120 carbapenemase producers, including 27 NDM producers. All 27 NDM-like carbapenemase producers of the reference collection were correctly detected in less than 15 min by the NDM LFIA, including 22 strains producing NDM-1, 2 producing NDM-4, 1 producing NDM-5, 1 producing NDM-7, and 1 producing NDM-9. All non-NDM-1 producers gave a negative result with the NDM LFIA. No cross-reaction was observed with carbapenemases (VIM, IMP, NDM, KPC, and OXA-48-like), extended-spectrum β-lactamases (ESBLs) (TEM, SHV, and CTX-M), AmpCs (CMY-2, DHA-2, and ACC-1), and oxacillinases (OXA-1, -2, -9, and -10). Similarly, among the 74 referred nonduplicate consecutive clinical isolates, all 7 NDM-like producers were identified. Overall, the sensitivity and specificity of the assay were 100% for NDM-like carbapenemase detection with strains cultured on agar. The NDM LFIA was efficient, rapid, and easy to implement in the routine workflow of a clinical microbiology laboratory for the confirmation of NDM-like carbapenemase-producing Enterobacteriaceae. PMID:28404680

  12. HIGH-PRECISION RADIO AND INFRARED ASTROMETRY OF LSPM J1314+1320AB. I. PARALLAX, PROPER MOTIONS, AND LIMITS ON PLANETS

    Energy Technology Data Exchange (ETDEWEB)

    Forbrich, Jan [University of Vienna, Department of Astrophysics, Türkenschanzstr. 17, A-1180 Vienna (Austria); Dupuy, Trent J.; Rizzuto, Aaron; Mann, Andrew W.; Kraus, Adam L. [The University of Texas at Austin, Department of Astronomy, 2515 Speedway C1400, Austin, TX 78712 (United States); Reid, Mark J.; Berger, Edo [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Liu, Michael C.; Aller, Kimberly [Institute for Astronomy, University of Hawai’i, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States)

    2016-08-10

    We present multi-epoch astrometric radio observations with the Very Long Baseline Array (VLBA) of the young ultracool-dwarf binary LSPM J1314+1320AB. The radio emission comes from the secondary star. Combining the VLBA data with Keck near-infrared adaptive-optics observations of both components, a full astrometric fit of parallax (π {sub abs} = 57.975 ± 0.045 mas, corresponding to a distance of d = 17.249 ± 0.013 pc), proper motion (μ {sub α} {sub cos} {sub δ} = −247.99 ± 0.10 mas yr{sup −1}, μ {sub δ} = −183.58 ± 0.22 mas yr{sup −1}), and orbital motion is obtained. Despite the fact that the two components have nearly identical masses to within ±2%, the secondary’s radio emission exceeds that of the primary by a factor of ≳30, suggesting a difference in stellar rotation history, which could result in different magnetic field configurations. Alternatively, the emission could be anisotropic and beamed toward us for the secondary but not for the primary. Using only reflex motion, we exclude planets of mass 0.7–10 M {sub jup} with orbital periods of 600–10 days, respectively. Additionally, we use the full orbital solution of the binary to derive an upper limit for the semimajor axis of 0.23 au for stable planetary orbits within this system. These limits cover a parameter space that is inaccessible with, and complementary to, near-infrared radial velocity surveys of ultracool dwarfs. Our absolute astrometry will constitute an important test for the astrometric calibration of Gaia .

  13. Present status of the 4-m ILMT data reduction pipeline: application to space debris detection and characterization

    Science.gov (United States)

    Pradhan, Bikram; Delchambre, Ludovic; Hickson, Paul; Akhunov, Talat; Bartczak, Przemyslaw; Kumar, Brajesh; Surdej, Jean

    2018-04-01

    The 4-m International Liquid Mirror Telescope (ILMT) located at the ARIES Observatory (Devasthal, India) has been designed to scan at a latitude of +29° 22' 26" a band of sky having a width of about half a degree in the Time Delayed Integration (TDI) mode. Therefore, a special data-reduction and analysis pipeline to process online the large amount of optical data being produced has been dedicated to it. This requirement has led to the development of the 4-m ILMT data reduction pipeline, a new software package built with Python in order to simplify a large number of tasks aimed at the reduction of the acquired TDI images. This software provides astronomers with specially designed data reduction functions, astrometry and photometry calibration tools. In this paper we discuss the various reduction and calibration steps followed to reduce TDI images obtained in May 2015 with the Devasthal 1.3m telescope. We report here the detection and characterization of nine space debris present in the TDI frames.

  14. The provision for health needs in less developed countries with reference to Bophuthatswana.

    Science.gov (United States)

    Procter, J

    1989-01-01

    The concept of health for all by the year 2000 envisioned by the WHO can be achieved only by making strides against poverty-linked population growth and economic stagnation. 80% of the 1.9 million population of Bophuthatswana that became independent from South Africa in 1977 live in rural areas. Before independence virtually no health service existed. The Department of Health and Social Services envisions health care for all by providing a treatment center in every village; 3 beds/1000 population is targeted by 1992; and a doctor-patient ratio of 1/10,000 people (the ratio in South Africa is 1/1423). Most doctors are foreigners on contract and their qualifications are often inadequate. The shortfall of black doctors and nurses is attributable to apartheid policies. The health services structure has 3 branches: medical and paramedical, preventive and promotive, and social welfare. Primary health care is developed with traditional healers. 50% of children aged 12-36 months are immunized by the preventive branch. Alcoholism is a serious issue, and glue sniffing is frequent among delinquent children in shanty towns. In less developed countries good medical care tends to vary inversely with the needs of the population. Africa's debt situation and the freeze on new loans has pushed the idea of privatization of health services into the forefront. The US example has shown that commercial medicine is expensive because of entrenched medical and insurance interests often leading to superfluous operations. The state should allow private entrepreneurship in health care while guaranteeing protection for the patients and recycling taxes imposed into rural clinics.

  15. Less Words, More Action: Using On-the-Fly Videos and Screenshots in Your Library's IM/Chat and Email Reference Transactions

    Science.gov (United States)

    Sekyere, Kwabena

    2010-01-01

    Email and chat/IM reference services have become a convenient and easily accessible option for the online community and libraries, particularly with increasing amounts of library resources now available electronically. This article gives an overview of Jing, which can be used to produce videos and screenshots on-the-fly, and demonstrates how to…

  16. The CEBAF fiber optic phase reference system

    International Nuclear Information System (INIS)

    Crawford, K.; Simrock, S.; Hovater, C.; Krycuk, A.

    1995-01-01

    The specified phase stability of the CEBAF RF distribution system is 2.9 degree rms per linac. Stability is achieved through the use of a temperature and pressure regulated coaxial drive line. Purpose of the fiber optic phase reference system is to monitor the relative phase at the beginning and ending of this drive line, between linacs, injector and separator to determine drift due to ambient temperature fluctuations. The system utilizes an Ortel 1310 nm single mode laser driving Sumitumo optical fiber to distribute a reference signal at 1497 MHz. Phase of this reference signal is compared to the 1427 MHz (LO) and the 70 MHz (IF) via a 360 degree phase detector. The detected information is then routed to the CEBAF control system for display with a specified resolution of ±0.2 degree over a 20 degree phase delta

  17. Pedestrian Detection by Laser Scanning and Depth Imagery

    Science.gov (United States)

    Barsi, A.; Lovas, T.; Molnar, B.; Somogyi, A.; Igazvolgyi, Z.

    2016-06-01

    Pedestrian flow is much less regulated and controlled compared to vehicle traffic. Estimating flow parameters would support many safety, security or commercial applications. Current paper discusses a method that enables acquiring information on pedestrian movements without disturbing and changing their motion. Profile laser scanner and depth camera have been applied to capture the geometry of the moving people as time series. Procedures have been developed to derive complex flow parameters, such as count, volume, walking direction and velocity from laser scanned point clouds. Since no images are captured from the faces of pedestrians, no privacy issues raised. The paper includes accuracy analysis of the estimated parameters based on video footage as reference. Due to the dense point clouds, detailed geometry analysis has been conducted to obtain the height and shoulder width of pedestrians and to detect whether luggage has been carried or not. The derived parameters support safety (e.g. detecting critical pedestrian density in mass events), security (e.g. detecting prohibited baggage in endangered areas) and commercial applications (e.g. counting pedestrians at all entrances/exits of a shopping mall).

  18. Astrophysical techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kitchin, C R

    1984-01-01

    The subject is covered in chapters, entitled: detectors (optical and infrared detection; radio and microwave detection; X-ray and gamma-ray detection; cosmic ray detectors; neutrino detectors; gravitational radiation); imaging (photography; electronic imaging; scanning; interferometry; speckle interferometry; occultations; radar); photometry and photometers; spectroscopy and spectroscopes; other techniques (astrometry; polarimetry; solar studies; magnetometry). Appendices: magnitudes and spectral types of bright stars; north polar sequence; standard stars for the UBV photometric system; standard stars for the UVBY photometric system; standard stars for MK spectral types; standard stars for polarimetry; Julian date; catalogues; answers to the exercises.

  19. Evaluation of a reference material for glycated haemoglobin

    NARCIS (Netherlands)

    Weykamp, CW; Penders, TJ; Muskiet, FAJ; vanderSlik, W

    The use of lyophilized blood as a reference material for glycated haemoglobin was investigated with respect to IFCC criteria for calibrators and control materials. Ninety-two laboratories, using 11 methods, detected no changes in glycated haemoglobin content when the lyophilizate was stored for one

  20. Estimation of sensitivity, specificity and predictive values of two serologic tests for the detection of antibodies against Actinobacillus pleuropneumoniae serotype 2 in the absence of a reference test (gold standard)

    DEFF Research Database (Denmark)

    Enøe, Claes; Andersen, Søren; Sørensen, Vibeke

    2001-01-01

    Latent-class models were used to determine the sensitivity, specificity and predictive values of a polyclonal blocking enzyme-linked immunosorbent assay (ELISA) and a modified complement-fixation test (CFT) when there was no reference test. The tests were used for detection of antibodies against ...

  1. USA hCG reference service, 10-year report.

    Science.gov (United States)

    Cole, Laurence A; Laidler, Laura L; Muller, Carolyn Y

    2010-08-01

    The USA hCG Reference Service has been dealing with cases of persistent low levels of hCG and gestational trophoblastic diseases for 10years. Here we present the complete experience. Total hCG in serum and urine was measured using the Siemen's Immulite 1000 assay. Hyperglycosylated hCG, nicked hCG, free ss-subunit and ss-core fragment were measured using microtiterplate assays with antibodies B152, B151, FBT11 and B210, respectively. The USA hCG Reference Service has identified 83 cases of false-positive hCG, 71 cases of aggressive gestational trophoblastic disease (GTD), 52 cases of minimally invasive GTD, 168 cases of quiescent GTD and 22 cases of placenta site trophoblastic tumor (PSTT). In addition, 103 cases of pituitary hCG have been identified, 60 cases of nontrophoblastic tumor, 4 cases of inherited hCG and 2 cases of Munchausen's syndrome. This is 565 cases total. Multiple new methods are described and tested for diagnosing all of these disorders. The USA hCG Reference Service experience shows new methods for detecting multiple hCG-related disorders and recommends new approaches for detecting these hCG-related disorders. 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Observations of pretreatment prostate-specific antigen doubling time in 107 patients referred for definitive radiotherapy

    International Nuclear Information System (INIS)

    Lee, W. Robert; Hanks, Gerald E.; Corn, Benjamin W.; Schultheiss, Timothy E.

    1995-01-01

    Purpose: To determine pretreatment prostate-specific antigen doubling times (PSADT) in patients referred for definitive radiotherapy. Methods and Materials: One hundred and seven patients with histologically proven nonmetastatic prostate cancer and an elevated prostate-specific antigen (PSA) who were referred for radiation therapy had three serum PSA values obtained prior to the start of definitive therapy. Prostate-specific antigen doubling times were calculated by linear regression. Results: Prostate-specific antigen values increased during the period of observation in 78 patients (73%). Forty-three patients (40%) had calculated PSADT of less than 2 years and of those patients with pretreatment serum PSA values of greater than 10 ng/mL more than 50% has calculated PSADT of less than 2 years. Conclusions: A significant minority of patients referred for radiotherapy have calculated PSADT of less than 2 years. The significance of this relatively fast growth rate is as yet undetermined, but suggests that patients referred for radiotherapy may have aggressive disease prior to treatment

  3. Precision Orbit of δ Delphini and Prospects for Astrometric Detection of Exoplanets

    Science.gov (United States)

    Gardner, Tyler; Monnier, John D.; Fekel, Francis C.; Williamson, Mike; Duncan, Douglas K.; White, Timothy R.; Ireland, Michael; Adams, Fred C.; Barman, Travis; Baron, Fabien; ten Brummelaar, Theo; Che, Xiao; Huber, Daniel; Kraus, Stefan; Roettenbacher, Rachael M.; Schaefer, Gail; Sturmann, Judit; Sturmann, Laszlo; Swihart, Samuel J.; Zhao, Ming

    2018-03-01

    Combining visual and spectroscopic orbits of binary stars leads to a determination of the full 3D orbit, individual masses, and distance to the system. We present a full analysis of the evolved binary system δ Delphini using astrometric data from the MIRC and PAVO instruments on the CHARA long-baseline interferometer, 97 new spectra from the Fairborn Observatory, and 87 unpublished spectra from the Lick Observatory. We determine the full set of orbital elements for δ Del, along with masses of 1.78 ± 0.07 M ⊙ and 1.62 ± 0.07 M ⊙ for each component, and a distance of 63.61 ± 0.89 pc. These results are important in two contexts: for testing stellar evolution models and for defining the detection capabilities for future planet searches. We find that the evolutionary state of this system is puzzling, as our measured flux ratios, radii, and masses imply a ∼200 Myr age difference between the components, using standard stellar evolution models. Possible explanations for this age discrepancy include mass transfer scenarios with a now-ejected tertiary companion. For individual measurements taken over a span of two years, we achieve 2 M J on orbits >0.75 au around individual components of hot binary stars via differential astrometry.

  4. Resampling methods in Microsoft Excel® for estimating reference intervals.

    Science.gov (United States)

    Theodorsson, Elvar

    2015-01-01

    Computer-intensive resampling/bootstrap methods are feasible when calculating reference intervals from non-Gaussian or small reference samples. Microsoft Excel® in version 2010 or later includes natural functions, which lend themselves well to this purpose including recommended interpolation procedures for estimating 2.5 and 97.5 percentiles. 
The purpose of this paper is to introduce the reader to resampling estimation techniques in general and in using Microsoft Excel® 2010 for the purpose of estimating reference intervals in particular.
 Parametric methods are preferable to resampling methods when the distributions of observations in the reference samples is Gaussian or can transformed to that distribution even when the number of reference samples is less than 120. Resampling methods are appropriate when the distribution of data from the reference samples is non-Gaussian and in case the number of reference individuals and corresponding samples are in the order of 40. At least 500-1000 random samples with replacement should be taken from the results of measurement of the reference samples.

  5. Finding the joker among the maize endogenous reference genes for genetically modified organism (GMO) detection.

    Science.gov (United States)

    Paternò, Annalisa; Marchesi, Ugo; Gatto, Francesco; Verginelli, Daniela; Quarchioni, Cinzia; Fusco, Cristiana; Zepparoni, Alessia; Amaddeo, Demetrio; Ciabatti, Ilaria

    2009-12-09

    The comparison of five real-time polymerase chain reaction (PCR) methods targeted at maize ( Zea mays ) endogenous sequences is reported. PCR targets were the alcohol dehydrogenase (adh) gene for three methods and high-mobility group (hmg) gene for the other two. The five real-time PCR methods have been checked under repeatability conditions at several dilution levels on both pooled DNA template from several genetically modified (GM) maize certified reference materials (CRMs) and single CRM DNA extracts. Slopes and R(2) coefficients of all of the curves obtained from the adopted regression model were compared within the same method and among all of the five methods, and the limit of detection and limit of quantitation were analyzed for each PCR system. Furthermore, method equivalency was evaluated on the basis of the ability to estimate the target haploid genome copy number at each concentration level. Results indicated that, among the five methods tested, one of the hmg-targeted PCR systems can be considered equivalent to the others but shows the best regression parameters and a higher repeteability along the dilution range. Thereby, it is proposed as a valid module to be coupled to different event-specific real-time PCR for maize genetically modified organism (GMO) quantitation. The resulting practicability improvement on the analytical control of GMOs is discussed.

  6. Roaming Reference: Reinvigorating Reference through Point of Need Service

    Directory of Open Access Journals (Sweden)

    Kealin M. McCabe

    2011-11-01

    Full Text Available Roaming reference service was pursued as a way to address declining reference statistics. The service was staffed by librarians armed with iPads over a period of six months during the 2010-2011 academic year. Transactional statistics were collected in relation to query type (Research, Facilitative or Technology, location and approach (librarian to patron, patron to librarian or via chat widget. Overall, roaming reference resulted in an additional 228 reference questions, 67% (n=153 of which were research related. Two iterations of the service were implemented, roaming reference as a standalone service (Fall 2010 and roaming reference integrated with traditional reference desk duties (Winter 2011. The results demonstrate that although the Weller Library’s reference transactions are declining annually, they are not disappearing. For a roaming reference service to succeed, it must be a standalone service provided in addition to traditional reference services. The integration of the two reference models (roaming reference and reference desk resulted in a 56% decline in the total number of roaming reference questions from the previous term. The simple act of roaming has the potential to reinvigorate reference services as a whole, forcing librarians outside their comfort zones, allowing them to reach patrons at their point of need.

  7. Spectrally efficient polarization multiplexed direct-detection OFDM system without frequency gap.

    Science.gov (United States)

    Wei, Chia-Chien; Zeng, Wei-Siang; Lin, Chun-Ting

    2016-01-25

    We experimentally demonstrate a spectrally efficient direct-detection orthogonal frequency-division multiplexing (DD-OFDM) system. In addition to polarization-division multiplexing, removing the frequency gap further improves the spectral efficiency of the OFDM system. The frequency gap between a reference carrier and OFDM subcarriers avoids subcarrier-to-subcarrier beating interference (SSBI) in traditional DD-OFDM systems. Without dynamic polarization control, the resulting interference after square-law direct detection in the proposed gap-less system is polarization-dependent and composed of linear inter-carrier interference (ICI) and nonlinear SSBI. Thus, this work proposes an iterative multiple-input multiple-output detection scheme to remove the mixed polarization-dependent interference. Compared to the previous scheme, which only removes ICI, the proposed scheme can further eliminate SSBI to achieve the improvement of ∼ 7 dB in signal-to-noise ratio. Without the need for polarization control, we successfully utilize 7-GHz bandwidth to transmit a 39.5-Gbps polarization multiplexed OFDM signal over 100 km.

  8. ENAA of iodine in standard reference material lyophilized human urine

    International Nuclear Information System (INIS)

    Zhang Yongbao; Wang Ke; Wang Ganfeng

    1997-01-01

    The contents of iodine in two kinds of standard reference materials lyophilized human urine are determined by ENAA. The sensitivity of this method is ten times higher than that of TNAA, and the relative standard deviations of ten measurements are 2.9% and 3.3%, respectively. Two certificated reference samples are used for verification of the analysis. The analytical results are in agreement with the recommended values, and the relative error is less than 3%

  9. Supersonic flaw detection device for nozzle

    International Nuclear Information System (INIS)

    Hata, Moriki.

    1996-01-01

    In a supersonic flaw detection device to be attached to a body surface of a reactor pressure vessel for automatically detecting flaws of a welded portion of a horizontally connected nozzle by using supersonic waves, a running vehicle automatically running along a circumferential direction of the nozzle comprises a supersonic flaw detection means for detecting flaws of the welded portion of the nozzle by using supersonic waves, and an inclination angle sensor for detecting the inclination angle of the running vehicle relative to the central axis of the nozzle. The running distance of the vehicle running along the circumference of the nozzle, namely, the position of the running vehicle from a reference point of the nozzle can be detected accurately by dividing the distance around the nozzle by the inclination angle detected by the inclination angle sensor. Accordingly, disadvantages in the prior art, for example, that the detected values obtained by using an encoder are changed by slipping or idle running of the magnet wheels are eliminated, and accurate flaw detection can be conducted. In addition, an operation of visually adjusting the reference point for the device can be eliminated. An operator's exposure dose can be reduced. (N.H.)

  10. Creatine and guanidinoacetate reference values in a French population

    NARCIS (Netherlands)

    Joncquel-Cheval Curt, M.; Cheillan, D.; Briand, G.; Salomons, G.S.; Mention-Mulliez, K.; Dobbelaere, D.; Cuisset, J.M.; Lion-Francois, L.; Portes, V.D.; Chabli, A.; Valayannopoulos, V.; Benoist, J.F.; Pinard, J.M.; Simard, G.; Douay, O.; Deiva, K.; Tardieu, M.; Afenjar, A.; Heron, D.; Rivier, F.; Chabrol, B.; Prieur, F.; Cartault, F.; Pitelet, G.; Goldenberg, A.; Bekri, S.; Gerard, M.; Delorme, R.; Porchet, N.; Vianey-Saban, C.; Vamecq, J.

    2013-01-01

    Creatine and guanidinoacetate are biomarkers of creatine metabolism. Their assays in body fluids may be used for detecting patients with primary creatine deficiency disorders (PCDD), a class of inherited diseases. Their laboratory values in blood and urine may vary with age, requiring that reference

  11. Evaluation of a new 10 mA DC current reference standard

    CERN Document Server

    Fernqvist, G; Power, F

    2002-01-01

    A new DC current reference standard has been developed as a component in a Current calibration hierarchy in the LHC project at CERN. The standard provides 10 mA DC current with an accuracy less than 0.5 ppm, drift less than 2 ppm/year and compliance error less than 0.1 ppm for 0-10 V. The paper gives the results from two years evaluation of a series of 5 units.

  12. A Novel Reference Plasmid for the Qualitative Detection of Genetically Modified Rice in Food and Feed

    Directory of Open Access Journals (Sweden)

    Liang Li

    2015-01-01

    Full Text Available Rice is one of the most important food crops in the world. Genetically modified (GM technology has been used in rice to confer herbicide tolerance and pathogen or insect resistance. China invests heavily in research on GM rice. By the end of 2014, at least 250 transgenic rice lines had been developed in China. To monitor the presence of GM rice in food and feed, we collected information on foreign elements from 250 transgenic rice lines and found 5 elements, including the Agrobacterium tumefaciens nopaline synthase terminator (T-NOS, the cauliflower mosaic virus 35S promoter (CaMV35S, the ubiquitin gene (Ubi, the bar gene, and the hygromycin phosphotransferase gene (Hpt, that are commonly present in GM rice. Therefore, we constructed a novel plasmid (pBJGMM001 that contains fragments of these elements and two endogenous reference genes (the sucrose phosphate synthase gene, SPS, and the phosphoenolpyruvate carboxylase gene, PEPC. pBJGMM001 can serve as a standard for detecting 96% of GM rice lines in China. The primers, amplicons, reaction mixture, and PCR program were developed based on Chinese National Standards. The protocol was validated and determined to be suitable for practical use in monitoring and identifying GM rice.

  13. A novel reference plasmid for the qualitative detection of genetically modified rice in food and feed.

    Science.gov (United States)

    Li, Liang; Dong, Mei; An, Na; Liang, Lixia; Wan, Yusong; Jin, Wujun

    2015-01-01

    Rice is one of the most important food crops in the world. Genetically modified (GM) technology has been used in rice to confer herbicide tolerance and pathogen or insect resistance. China invests heavily in research on GM rice. By the end of 2014, at least 250 transgenic rice lines had been developed in China. To monitor the presence of GM rice in food and feed, we collected information on foreign elements from 250 transgenic rice lines and found 5 elements, including the Agrobacterium tumefaciens nopaline synthase terminator (T-NOS), the cauliflower mosaic virus 35S promoter (CaMV35S), the ubiquitin gene (Ubi), the bar gene, and the hygromycin phosphotransferase gene (Hpt), that are commonly present in GM rice. Therefore, we constructed a novel plasmid (pBJGMM001) that contains fragments of these elements and two endogenous reference genes (the sucrose phosphate synthase gene, SPS, and the phosphoenolpyruvate carboxylase gene, PEPC). pBJGMM001 can serve as a standard for detecting 96% of GM rice lines in China. The primers, amplicons, reaction mixture, and PCR program were developed based on Chinese National Standards. The protocol was validated and determined to be suitable for practical use in monitoring and identifying GM rice.

  14. CT pulmonary angiography: increasingly diagnosing less severe pulmonary emboli.

    Directory of Open Access Journals (Sweden)

    Andrew J Schissler

    Full Text Available It is unknown whether the observed increase in computed tomography pulmonary angiography (CTPA utilization has resulted in increased detection of pulmonary emboli (PEs with a less severe disease spectrum.Trends in utilization, diagnostic yield, and disease severity were evaluated for 4,048 consecutive initial CTPAs performed in adult patients in the emergency department of a large urban academic medical center between 1/1/2004 and 10/31/2009. Transthoracic echocardiography (TTE findings and peak serum troponin levels were evaluated to assess for the presence of PE-associated right ventricular (RV abnormalities (dysfunction or dilatation and myocardial injury, respectively. Statistical analyses were performed using multivariate logistic regression.268 CTPAs (6.6% were positive for acute PE, and 3,780 (93.4% demonstrated either no PE or chronic PE. There was a significant increase in the likelihood of undergoing CTPA per year during the study period (odds ratio [OR] 1.05, 95% confidence interval [CI] 1.04-1.07, P<0.01. There was no significant change in the likelihood of having a CTPA diagnostic of an acute PE per year (OR 1.03, 95% CI 0.95-1.11, P = 0.49. The likelihood of diagnosing a less severe PE on CTPA with no associated RV abnormalities or myocardial injury increased per year during the study period (OR 1.39, 95% CI 1.10-1.75, P = 0.01.CTPA utilization has risen with no corresponding change in diagnostic yield, resulting in an increase in PE detection. There is a concurrent rise in the likelihood of diagnosing a less clinically severe spectrum of PEs.

  15. CT Pulmonary Angiography: Increasingly Diagnosing Less Severe Pulmonary Emboli

    Science.gov (United States)

    Schissler, Andrew J.; Rozenshtein, Anna; Kulon, Michal E.; Pearson, Gregory D. N.; Green, Robert A.; Stetson, Peter D.; Brenner, David J.; D'Souza, Belinda; Tsai, Wei-Yann; Schluger, Neil W.; Einstein, Andrew J.

    2013-01-01

    Background It is unknown whether the observed increase in computed tomography pulmonary angiography (CTPA) utilization has resulted in increased detection of pulmonary emboli (PEs) with a less severe disease spectrum. Methods Trends in utilization, diagnostic yield, and disease severity were evaluated for 4,048 consecutive initial CTPAs performed in adult patients in the emergency department of a large urban academic medical center between 1/1/2004 and 10/31/2009. Transthoracic echocardiography (TTE) findings and peak serum troponin levels were evaluated to assess for the presence of PE-associated right ventricular (RV) abnormalities (dysfunction or dilatation) and myocardial injury, respectively. Statistical analyses were performed using multivariate logistic regression. Results 268 CTPAs (6.6%) were positive for acute PE, and 3,780 (93.4%) demonstrated either no PE or chronic PE. There was a significant increase in the likelihood of undergoing CTPA per year during the study period (odds ratio [OR] 1.05, 95% confidence interval [CI] 1.04–1.07, P<0.01). There was no significant change in the likelihood of having a CTPA diagnostic of an acute PE per year (OR 1.03, 95% CI 0.95–1.11, P = 0.49). The likelihood of diagnosing a less severe PE on CTPA with no associated RV abnormalities or myocardial injury increased per year during the study period (OR 1.39, 95% CI 1.10–1.75, P = 0.01). Conclusions CTPA utilization has risen with no corresponding change in diagnostic yield, resulting in an increase in PE detection. There is a concurrent rise in the likelihood of diagnosing a less clinically severe spectrum of PEs. PMID:23776522

  16. Fundus auto fluorescence and spectral domain ocular coherence tomography in the early detection of chloroquine retinopathy

    OpenAIRE

    Megan B. Goodman; Ari Ziskind

    2015-01-01

    Purpose: To determine the sensitivity of spectral domain ocular coherence tomography (SD-OCT) and fundus auto fluorescence (FAF) images as a screening test to detect early changes in the retina prior to the onset of chloroquine retinopathy. Method: The study was conducted using patients taking chloroquine (CQ), referred by the Rheumatology Department to the Ophthalmology Department at Tygerberg Academic Hospital. Group A consisted of 59 patients on CQ for less than 5 years, and Group B co...

  17. Superpower Crises in a Less Confrontational World: Results of an Experimental Simulation

    Science.gov (United States)

    1990-04-01

    interteam communications via RAND’s electronic mail system for gaming purposes. 2 The "pilot runs" were designated Games Three and Four, and are referred... game , the impact of a changing real-world international context-a more benign image of the adversary and a less competitive superpower relationship...information overload they faced. Several believed that these problems were game artifacts (which they attributed to our use of the electronic mail system

  18. PEDESTRIAN DETECTION BY LASER SCANNING AND DEPTH IMAGERY

    Directory of Open Access Journals (Sweden)

    A. Barsi

    2016-06-01

    Full Text Available Pedestrian flow is much less regulated and controlled compared to vehicle traffic. Estimating flow parameters would support many safety, security or commercial applications. Current paper discusses a method that enables acquiring information on pedestrian movements without disturbing and changing their motion. Profile laser scanner and depth camera have been applied to capture the geometry of the moving people as time series. Procedures have been developed to derive complex flow parameters, such as count, volume, walking direction and velocity from laser scanned point clouds. Since no images are captured from the faces of pedestrians, no privacy issues raised. The paper includes accuracy analysis of the estimated parameters based on video footage as reference. Due to the dense point clouds, detailed geometry analysis has been conducted to obtain the height and shoulder width of pedestrians and to detect whether luggage has been carried or not. The derived parameters support safety (e.g. detecting critical pedestrian density in mass events, security (e.g. detecting prohibited baggage in endangered areas and commercial applications (e.g. counting pedestrians at all entrances/exits of a shopping mall.

  19. Digital Receiver Design for Transmitted Reference Ultra-Wideband Systems

    NARCIS (Netherlands)

    Wang, Y.; Leus, G.; Van der Veen, A.J.

    2009-01-01

    A complete detection, channel estimation, synchronization, and equalization scheme for a transmitted reference (TR) ultra-wideband (UWB) system is proposed in this paper. The scheme is based on a data model which admits a moderate data rate and takes both the interframe interference (IFI) and the

  20. Local sensitivity of per-recruit fishing mortality reference points.

    Science.gov (United States)

    Cadigan, N G; Wang, S

    2016-12-01

    We study the sensitivity of fishery management per-recruit harvest rates which may be part of a quantitative harvest strategy designed to achieve some objective for catch or population size. We use a local influence sensitivity analysis to derive equations that describe how these reference harvest rates are affected by perturbations to productivity processes. These equations give a basic theoretical understanding of sensitivity that can be used to predict what the likely impacts of future changes in productivity will be. Our results indicate that per-recruit reference harvest rates are more sensitive to perturbations when the equilibrium catch or population size per recruit, as functions of the harvest rate, have less curvature near the reference point. Overall our results suggest that per recruit reference points will, with some exceptions, usually increase if (1) growth rates increase, (2) natural mortality rates increase, or (3) fishery selectivity increases to an older age.

  1. SDS-PAGE in conjunction with match lane statistical analysis for the detection of meat adulteration

    International Nuclear Information System (INIS)

    Hegazy, R.A.; Nassef, A.E.

    2003-01-01

    Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) of seven meat types and two component mixtures of them were made. Banding patterns of resulting denstograms in conjunction with cluster analysi and match lane statistical analysis were used for the detection of meat adulteration. The use of beef as a reference meat have resulted in a clear distinction from goat, pork, chicken, turkey, camel meats and their mixture and camel meat. The use of pork meat as a reference was more assurate because of the low degrees of matching with all meats and their mixtures and consequently high abilities of differentiations. The purpose of identification. the purpose of identification of meat species arises from the desire of human, in general, to confirm what he eat ? for moslems the establisment that meat is free from pork type is most important. Another economic purpose is the detection of adulteration of valuable meat by less valuable types. Several attempts in different laboratories were done to serve this object but most of analytical techniques. Barbieri and formi (1999) were able to detect 5% of meat type in mixtures by isolelectric focusing and 1% of meat type by PCR technique in beef, pork, chicken and turkey meats. By crossover immunoelectrophoresis technique, zanon and vianello (1998) were also to detect a limit of 5% of specific meat in mixuters of beef, pork, mutton/lamb, horse and chicken meats

  2. Competitive PCR-High Resolution Melting Analysis (C-PCR-HRMA) for large genomic rearrangements (LGRs) detection: A new approach to assess quantitative status of BRCA1 gene in a reference laboratory.

    Science.gov (United States)

    Minucci, Angelo; De Paolis, Elisa; Concolino, Paola; De Bonis, Maria; Rizza, Roberta; Canu, Giulia; Scaglione, Giovanni Luca; Mignone, Flavio; Scambia, Giovanni; Zuppi, Cecilia; Capoluongo, Ettore

    2017-07-01

    Evaluation of copy number variation (CNV) in BRCA1/2 genes, due to large genomic rearrangements (LGRs), is a mandatory analysis in hereditary breast and ovarian cancers families, if no pathogenic variants are found by sequencing. LGRs cannot be detected by conventional methods and several alternative methods have been developed. Since these approaches are expensive and time consuming, identification of alternative screening methods for LGRs detection is needed in order to reduce and optimize the diagnostic procedure. The aim of this study was to investigate a Competitive PCR-High Resolution Melting Analysis (C-PCR-HRMA) as molecular tool to detect recurrent BRCA1 LGRs. C-PCR-HRMA was performed on exons 3, 14, 18, 19, 20 and 21 of the BRCA1 gene; exons 4, 6 and 7 of the ALB gene were used as reference fragments. This study showed that it is possible to identify recurrent BRCA1 LGRs, by melting peak height ratio between target (BRCA1) and reference (ALB) fragments. Furthermore, we underline that a peculiar amplicon-melting profile is associated to a specific BRCA1 LGR. All C-PCR-HRMA results were confirmed by Multiplex ligation-dependent probe amplification. C-PCR-HRMA has proved to be an innovative, efficient and fast method for BRCA1 LGRs detection. Given the sensitivity, specificity and ease of use, c-PCR-HRMA can be considered an attractive and powerful alternative to other methods for BRCA1 CNVs screening, improving molecular strategies for BRCA testing in the context of Massive Parallel Sequencing. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Determination of carbon-14 in environmental level, solid reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Blowers, Paul, E-mail: paul.blowers@cefas.co.uk [Cefas Lowestoft Laboratory, Pakefield Road, Lowestoft, Suffolk, NR33 0HT (United Kingdom); Caborn, Jane, E-mail: jane.a.caborn@nnl.co.uk [NNL, Springfields, Salwick, Preston, Lancashire, PR4 0XJ (United Kingdom); Dell, Tony [Veterinary Laboratories Agency, New Haw, Addlestone, Surrey, KT15 3NB (United Kingdom); Gingell, Terry [DSTL, Radiation Protection Services, Crescent Road, Alverstoke, Gosport, Hants, PO12 2DL (United Kingdom); Harms, Arvic [National Physical Laboratory, Hampton Road, Teddington, Middlesex, TW11 0LW (United Kingdom); Long, Stephanie [Radiological Protection Institute of Ireland, 3 Clonskeagh Square, Clonskeagh Road, Dublin 14, Ireland (United Kingdom); Sleep, Darren [Centre for Ecology and Hydrology, Lancaster Environment Centre, Library Avenue, Bailrigg, Lancaster, LA1 4AP (United Kingdom); Stewart, Charlie [UKAEA (Waste Management Group), Chemical Support Services, D1310/14, Dounreay, Thurso, Caithness, KW14 7TZ (United Kingdom); Walker, Jill [Radiocarbon Dating, The Old Stables, East Lockinge, Wantage, Oxon OX12 8QY (United Kingdom); Warwick, Phil E. [GAU-Radioanalytical, National Oceanography Centre Southampton, European Way, Southampton, SO14 3ZH (United Kingdom)

    2011-10-15

    An intercomparison exercise to determine the {sup 14}C activity concentrations in a range of solid, environmental level materials was conducted between laboratories in the UK. IAEA reference materials, C2, C6 and C7, and an in-house laboratory QA material were dispatched in 2006 to ten laboratories comprising of members of the Analyst Informal Working Group (AIWG) and one other invited party. The laboratories performed the determinations using a number of techniques, and using the results each one was evaluated in terms of levels of precision, sensitivity and limits of detection. The results of the study show that all techniques are capable of successfully analysing {sup 14}C in environmental level materials, however, a shortage of certified environmental reference materials exists. The suitability of the IAEA reference materials and other material for use as reference materials was also assessed.

  4. Determination of carbon-14 in environmental level, solid reference materials

    International Nuclear Information System (INIS)

    Blowers, Paul; Caborn, Jane; Dell, Tony; Gingell, Terry; Harms, Arvic; Long, Stephanie; Sleep, Darren; Stewart, Charlie; Walker, Jill; Warwick, Phil E.

    2011-01-01

    An intercomparison exercise to determine the 14 C activity concentrations in a range of solid, environmental level materials was conducted between laboratories in the UK. IAEA reference materials, C2, C6 and C7, and an in-house laboratory QA material were dispatched in 2006 to ten laboratories comprising of members of the Analyst Informal Working Group (AIWG) and one other invited party. The laboratories performed the determinations using a number of techniques, and using the results each one was evaluated in terms of levels of precision, sensitivity and limits of detection. The results of the study show that all techniques are capable of successfully analysing 14 C in environmental level materials, however, a shortage of certified environmental reference materials exists. The suitability of the IAEA reference materials and other material for use as reference materials was also assessed.

  5. Internet Astrometry

    Science.gov (United States)

    Caballero, Rafael; Argyle, R. W.

    Amateur astronomers can carry out scientific research in many different ways. Some activities require expensive telescopes, cameras, and often access to dark skies. But those who live in highly polluted areas, or do not have access to very specialized equipment, still have many possibilities; amongst which is using the online resources available from the internet. In this chapter we explore Aladin, Simbad, and VizieR, three resources created and maintained by the Centre de Données astronomiques de Strasbourg (CDS). Although these applications are intended for professional astronomers, they are also freely available for amateurs. They allow us to find and measure old neglected difficult pairs, discover new double stars, and in general have a better understanding of those tiny pairs of points of light that we love to observe, photograph and measure.

  6. Detection of argan oil adulteration with vegetable oils by high-performance liquid chromatography-evaporative light scattering detection.

    Science.gov (United States)

    Salghi, Rachid; Armbruster, Wolfgang; Schwack, Wolfgang

    2014-06-15

    Triacylglycerol profiles were selected as indicator of adulteration of argan oils to carry out a rapid screening of samples for the evaluation of authenticity. Triacylglycerols were separated by high-performance liquid chromatography-evaporative light scattering detection. Different peak area ratios were defined to sensitively detect adulteration of argan oil with vegetable oils such as sunflower, soy bean, and olive oil up to the level of 5%. Based on four reference argan oils, mean limits of detection and quantitation were calculated to approximately 0.4% and 1.3%, respectively. Additionally, 19 more argan oil reference samples were analysed by high-performance liquid chromatography-refractive index detection, resulting in highly comparative results. The overall strategy demonstrated a good applicability in practise, and hence a high potential to be transferred to routine laboratories. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. A localization algorithm of adaptively determining the ROI of the reference circle in image

    Science.gov (United States)

    Xu, Zeen; Zhang, Jun; Zhang, Daimeng; Liu, Xiaomao; Tian, Jinwen

    2018-03-01

    Aiming at solving the problem of accurately positioning the detection probes underwater, this paper proposed a method based on computer vision which can effectively solve this problem. The theory of this method is that: First, because the shape information of the heat tube is similar to a circle in the image, we can find a circle which physical location is well known in the image, we set this circle as the reference circle. Second, we calculate the pixel offset between the reference circle and the probes in the picture, and adjust the steering gear through the offset. As a result, we can accurately measure the physical distance between the probes and the under test heat tubes, then we can know the precise location of the probes underwater. However, how to choose reference circle in image is a difficult problem. In this paper, we propose an algorithm that can adaptively confirm the area of reference circle. In this area, there will be only one circle, and the circle is the reference circle. The test results show that the accuracy of the algorithm of extracting the reference circle in the whole picture without using ROI (region of interest) of the reference circle is only 58.76% and the proposed algorithm is 95.88%. The experimental results indicate that the proposed algorithm can effectively improve the efficiency of the tubes detection.

  8. Method of detecting leakage in nuclear reactor containment vessel

    International Nuclear Information System (INIS)

    Koba, Akitoshi; Goto, Seiichiro.

    1974-01-01

    Object: To permit accurate and prompt detection of leakage of a radioactive substance. Structure: The rate of change of such factors as radiation dose, temperature and pressure in the containment vessel, and each detected rate of change is compared with a reference value. The running cycle of the condensed drain exhausting pump in a drain collecting tank within a predetermined period is detected, and it is also compared with a reference value. These comparisons determine the absence or presence of leakage. (Kamimura, M.)

  9. High accuracy Primary Reference gas Mixtures for high-impact greenhouse gases

    Science.gov (United States)

    Nieuwenkamp, Gerard; Zalewska, Ewelina; Pearce-Hill, Ruth; Brewer, Paul; Resner, Kate; Mace, Tatiana; Tarhan, Tanil; Zellweger, Christophe; Mohn, Joachim

    2017-04-01

    Climate change, due to increased man-made emissions of greenhouse gases, poses one of the greatest risks to society worldwide. High-impact greenhouse gases (CO2, CH4 and N2O) and indirect drivers for global warming (e.g. CO) are measured by the global monitoring stations for greenhouse gases, operated and organized by the World Meteorological Organization (WMO). Reference gases for the calibration of analyzers have to meet very challenging low level of measurement uncertainty to comply with the Data Quality Objectives (DQOs) set by the WMO. Within the framework of the European Metrology Research Programme (EMRP), a project to improve the metrology for high-impact greenhouse gases was granted (HIGHGAS, June 2014-May 2017). As a result of the HIGHGAS project, primary reference gas mixtures in cylinders for ambient levels of CO2, CH4, N2O and CO in air have been prepared with unprecedented low uncertainties, typically 3-10 times lower than usually previously achieved by the NMIs. To accomplish these low uncertainties in the reference standards, a number of preparation and analysis steps have been studied and improved. The purity analysis of the parent gases had to be performed with lower detection limits than previously achievable. E.g., to achieve an uncertainty of 2•10-9 mol/mol (absolute) on the amount fraction for N2O, the detection limit for the N2O analysis in the parent gases has to be in the sub nmol/mol domain. Results of an OPO-CRDS analyzer set-up in the 5µm wavelength domain, with a 200•10-12 mol/mol detection limit for N2O, will be presented. The adsorption effects of greenhouse gas components at cylinder surfaces are critical, and have been studied for different cylinder passivation techniques. Results of a two-year stability study will be presented. The fit-for-purpose of the reference materials was studied for possible variation on isotopic composition between the reference material and the sample. Measurement results for a suit of CO2 in air

  10. A reference aerosol for a radon reference chamber

    Science.gov (United States)

    Paul, Annette; Keyser, Uwe

    1996-02-01

    The measurement of radon and radon progenies and the calibration of their detection systems require the production and measurement of aerosols well-defined in size and concentration. In the German radon reference chamber, because of its unique chemical and physical properties, carnauba wax is used to produce standard aerosols. The aerosol size spectra are measured on-line by an aerosol measurement system in the range of 10 nm to 1 μm aerodynamic diameter. The experimental set-ups for the study of adsorption of radioactive ions on aerosols as function of their size and concentration will be described, the results presented and further adaptations for an aerosol jet introduced (for example, for the measurement of short-lived neutron-rich isotopes). Data on the dependence of aerosol radius, ion concentration and element selectivity is collected by using a 252Cf-sf source. The fission products of this source range widely in elements, isotopes and charges. Adsorption and the transport of radioactive ions on aerosols have therefore been studied for various ions for the first time, simultaneously with the aerosol size on-line spectrometry.

  11. A reference aerosol for a radon reference chamber

    Energy Technology Data Exchange (ETDEWEB)

    Paul, A. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Keyser, U. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)

    1996-01-11

    The measurement of radon and radon progenies and the calibration of their detection systems require the production and measurement of aerosols well-defined in size and concentration. In the German radon reference chamber, because of its unique chemical and physical properties, carnauba wax is used to produce standard aerosols. The aerosol size spectra are measured on-line by an aerosol measurement system in the range of 10 nm to 1 {mu}m aerodynamic diameter. The experimental set-ups for the study of adsorption of radioactive ions on aerosols as function of their size and concentration are described, the results presented and further adaptations for an aerosol jet introduced (for example, for the measurement of short-lived neutron-rich isotopes). Data on the dependence of aerosol radius, ion concentration and element selectivity is collected by using a {sup 252}Cf-sf source. The fission products of this source range widely in elements, isotopes and charges. Adsorption and the transport of radioactive ions on aerosols have therefore been studied for various ions for the first time, simultaneously with the aerosol size on-line spectrometry. (orig.).

  12. A no-reference metric for perceived ringing artifacts in images

    NARCIS (Netherlands)

    Liu, H.; Klomp, N.; Heynderickx, I.E.J.

    2010-01-01

    A novel no-reference metric that can automatically quantify ringing annoyance in compressed images is presented. In the first step a recently proposed ringing region detection method extracts the regions which are likely to be impaired by ringing artifacts. To quantify ringing annoyance in these

  13. Accuracy of references and quotations in veterinary journals.

    Science.gov (United States)

    Hinchcliff, K W; Bruce, N J; Powers, J D; Kipp, M L

    1993-02-01

    The accuracy of references and quotations used to substantiate statements of fact in articles published in 6 frequently cited veterinary journals was examined. Three hundred references were randomly selected, and the accuracy of each citation was examined. A subset of 100 references was examined for quotational accuracy; ie, the accuracy with which authors represented the work or assertions of the author being cited. Of the 300 references selected, 295 were located, and 125 major errors were found in 88 (29.8%) of them. Sixty-seven (53.6%) major errors were found involving authors, 12 (9.6%) involved the article title, 14 (11.2%) involved the book or journal title, and 32 (25.6%) involved the volume number, date, or page numbers. Sixty-eight minor errors were detected. The accuracy of 111 quotations from 95 citations in 65 articles was examined. Nine quotations were technical and not classified, 86 (84.3%) were classified as correct, 2 (1.9%) contained minor misquotations, and 14 (13.7%) contained major misquotations. We concluded that misquotations and errors in citations occur frequently in veterinary journals, but at a rate similar to that reported for other biomedical journals.

  14. Threshold-driven optimization for reference-based auto-planning

    Science.gov (United States)

    Long, Troy; Chen, Mingli; Jiang, Steve; Lu, Weiguo

    2018-02-01

    We study threshold-driven optimization methodology for automatically generating a treatment plan that is motivated by a reference DVH for IMRT treatment planning. We present a framework for threshold-driven optimization for reference-based auto-planning (TORA). Commonly used voxel-based quadratic penalties have two components for penalizing under- and over-dosing of voxels: a reference dose threshold and associated penalty weight. Conventional manual- and auto-planning using such a function involves iteratively updating the preference weights while keeping the thresholds constant, an unintuitive and often inconsistent method for planning toward some reference DVH. However, driving a dose distribution by threshold values instead of preference weights can achieve similar plans with less computational effort. The proposed methodology spatially assigns reference DVH information to threshold values, and iteratively improves the quality of that assignment. The methodology effectively handles both sub-optimal and infeasible DVHs. TORA was applied to a prostate case and a liver case as a proof-of-concept. Reference DVHs were generated using a conventional voxel-based objective, then altered to be either infeasible or easy-to-achieve. TORA was able to closely recreate reference DVHs in 5-15 iterations of solving a simple convex sub-problem. TORA has the potential to be effective for auto-planning based on reference DVHs. As dose prediction and knowledge-based planning becomes more prevalent in the clinical setting, incorporating such data into the treatment planning model in a clear, efficient way will be crucial for automated planning. A threshold-focused objective tuning should be explored over conventional methods of updating preference weights for DVH-guided treatment planning.

  15. Detection of signals in noise

    CERN Document Server

    Whalen, Anthony D; Declaris, Nicholas

    1971-01-01

    Detection of Signals in Noise serves as an introduction to the principles and applications of the statistical theory of signal detection. The book discusses probability and random processes; narrowband signals, their complex representation, and their properties described with the aid of the Hilbert transform; and Gaussian-derived processes. The text also describes the application of hypothesis testing for the detection of signals and the fundamentals required for statistical detection of signals in noise. Problem exercises, references, and a supplementary bibliography are included after each c

  16. Evaluation of storage conditions for tritiated thymidine as reference organically-bound tritium in urine

    International Nuclear Information System (INIS)

    Duong, T.; Trivedi, A.

    1997-01-01

    Interlaboratory intercomparison exercises have used tritiated thymidine as a reference material for organically-bound tritium (OBT) measurements in urine. We have examined the effects of storage conditions on the degradation behavior of tritium from OBT to tritiated water (HTO) in artificial and natural human urine samples. Tritiated thymidine decomposed less readily in artificial urine than natural urine samples. The degradation rate of tritiated thymidine in artificial urine, at -20 deg C, is about 10% for the first month. The rate of tritium conversion from OBT to HTO is the same at 4 deg C, but this storage temperature is less preferable, because of the danger of microbial contamination in the reference samples. The storage of the reference urine samples beyond three months after the preparation date is not recommended for quality control measurement data. (author)

  17. Practical considerations in the development and application of reference levels

    International Nuclear Information System (INIS)

    Selby, J. M.; Kennedy, W. E. Jr.; Swinth, K. L.; Gilbert, R. O.; Soldat, J. K.

    1988-05-01

    Radiological exposures to the public during an accident that releases radioactive materials to the environment occur initially through the air pathway, secondly through a water pathway, and finally, through the food chain. From these exposure pathways, reference levels of radionuclides must be applied to limit public radiation doses. Such reference levels are difficult to develop and apply, particularly if the contaminants are transuranic elements such as plutonium. The reference level must be related to a resultant theoretical dose to the public through generic calculations. However, to permit rapid decisions after an accident, the reference levels need to be related to conditions or media in the environment that can be directly measured. They must also be tied to specific countermeasures such as sheltering, evacuation, or interdiction of drinking water or food supplies. This paper discusses the practical considerations in the development and application of reference levels for transuranic in the environment and the present capability to rapidly detect and quantify their concentrations following accidental contamination events. 16 refs., 3 tabs

  18. Comparison of multiplex RT-PCR and real-time HybProbe assay for serotyping of dengue virus using reference strains and clinical samples from India

    Directory of Open Access Journals (Sweden)

    Anita Chakravarti

    2016-01-01

    Full Text Available Background: Dengue virus serotyping is crucial from clinical management and epidemiological point of view. Aims: To compare efficacy of two molecular detection and typing methods, namely, multiplex reverse transcription polymerase chain reaction (RT-PCR and real-time Hybprobe assay using a panel of known dilution of four reference Dengue virus strains and a panel of sera collected from clinically suspected dengue patients. Settings: This study was conducted at a tertiary-care teaching hospital in Delhi, India. Materials and Methods: Dengue serotype specific virus strains were used as prototypes for serotyping assays. Viral load was quantified by quantitative real time reverse transcription polymerase chain reaction (qRT-PCR. Acute phase serum samples were collected from 79 patients with clinically suspected Dengue fever on their first day of presentation during September-October 2012. Viral RNA from serum and cell culture supernatant was extracted. Reverse transcription was carried out. Quantitative detection of DENV RNA from reference strain culture supernatants and each of the 79 patient samples by real-time PCR was performed using light cycler Taqman master mix kit. Serotyping was done by multiplex RT-PCR assay and Hybprobe assay. Results: The multiplex RT-PCR assay, though found to be 100% specific, couldn't serotype either patient or reference strains with viral load less than 1000 RNA copies/ml. The Hybprobe assay was found to have 100% specificity and had a lower limit of serotype detection of merely 3.54 RNA copies/ml. Conclusions: HybProbe assay has an important role especially in situations where serotyping is to be performed in clinical samples with low viral load.

  19. References and arrow notation instead of join operation in query languages

    Directory of Open Access Journals (Sweden)

    Alexandr Savinov

    2012-10-01

    Full Text Available We study properties of the join operation in query languages and describe some of its major drawbacks. We provide strong arguments against using joins as a main construct for retrieving related data elements in general purpose query languages and argue for using references instead. Since conventional references are quite restrictive when applied to data modeling and query languages, we propose to use generalized references as they are defined in the concept-oriented model (COM. These references are used by two new operations, called projection and de-projection, which are denoted by right and left arrows and therefore this access method is referred to as arrow notation. We demonstrate advantages of the arrow notation in comparison to joins and argue that it makes queries simpler, more natural, easier to understand, and the whole query writing process more productive and less error-prone.

  20. On the semantic content of grammatical gender and its impact on the representation of human referents.

    Science.gov (United States)

    Irmen, Lisa; Kurovskaja, Julia

    2010-01-01

    Grammatical gender has been shown to provide natural gender information about human referents. However, due to formal and conceptual differences between masculine and feminine forms, it remains an open question whether these gender categories influence the processing of person information to the same degree. Experiment 1 compared the semantic content of masculine and feminine grammatical gender by combining masculine and feminine role names with either gender congruent or incongruent referents (e.g., Dieser Lehrer [masc.]/Diese Lehrerin [fem.] ist mein Mann/meine Frau; This teacher is my husband/my wife). Participants rated sentences in terms of correctness and customariness. In Experiment 2, in addition to ratings reading times were recorded to assess processing more directly. Both experiments were run in German. Sentences with grammatically feminine role names and gender incongruent referents were rated as less correct and less customary than those with masculine forms and incongruent referents. Combining a masculine role name with an incongruent referent slowed down reading to a greater extent than combining a feminine role name with an incongruent referent. Results thus specify the differential effects of masculine and feminine grammatical gender in denoting human referents.

  1. Referent 3D tumor model at cellular level in radionuclide therapy

    International Nuclear Information System (INIS)

    Spaic, R.; Ilic, R.D.; Petrovic, B.J.

    2002-01-01

    Aim Conventional internal dosimetry has a lot of limitations because of tumor dose nonuniformity. The best approach for absorbed dose at cellular level for different tumors in radionuclide therapy calculation is Monte Carlo method. The purpose of this study is to introduce referent tumor 3D model at cellular level for Monte Carlo simulation study in radionuclide therapy. Material and Methods The moment when tumor is detectable and when same therapy can start is time period in which referent 3D tumor model at cellular level was defined. In accordance with tumor growth rate at that moment he was a sphere with same radius (10 000 μm). In that tumor there are cells or cluster of cells, which are randomly distributed spheres. Distribution of cells/cluster of cells can be calculated from histology data but it was assumed that this distribution is normal with the same mean value and standard deviation (100±50 mm). Second parameter, which was selected to define referent tumor, is volume density of cells (30%). In this referent tumor there are no necroses. Stroma is defined as space between spheres with same concentration of materials as in spheres. Results: Referent tumor defined on this way have about 2,2 10 5 cells or cluster of cells random distributed. Using this referent 3D tumor model and for same concentration of radionuclides (1:100) and energy of beta emitters (1000 keV) which are homogeneously distributed in labeled cells absorbed dose for all cells was calculated. Simulations are done using FOTELP Monte Carlo code, which is modified for this purposes. Results of absorbed dose in cells are given in numerical values (1D distribution) and as the images (2D or 3D distributions). Conclusion Geometrical module for Monte Carlo simulation study can be standardized by introducing referent 3D tumor model at cellular level. This referent 3D tumor model gives most realistic presentation of different tumors at the moment of their detectability. Referent 3D tumor model at

  2. NEAT: an astrometric space telescope to search for habitable exoplanets in the solar neighborhood

    Science.gov (United States)

    Crouzier, A.; Malbet, F.; Kern, P.; Feautrier, P.; Preiss, O.; Martin, G.; Henault, F.; Stadler, E.; Lafrasse, S.; Behar, E.; Saintpe, M.; Dupont, J.; Potin, S.; Lagage, P.-O.; Cara, C.; Leger, A.; Leduigou, J.-M.; Shao, M.; Goullioud, R.

    2014-03-01

    The last decade has witnessed a spectacular development of exoplanet detection techniques, which led to an exponential number of discoveries and a great diversity of known exoplanets. However, it must be noted that the quest for the holy grail of astrobiology, i.e. a nearby terrestrial exoplanet in habitable zone around a solar type star, is still ongoing and proves to be very hard. Radial velocities will have to overcome stellar noise if there are to discover habitable planets around stars more massive than M ones. For very close systems, transits are impeded by their low geometrical probability. Here we present an alternative concept: space astrometry. NEAT (Nearby Earth Astrometric Telescope) is a concept of astrometric mission proposed to ESA which goal is to make a whole sky survey of close (less then 20 pc) planetary systems. The detection limit required for the instrument is the astrometric signal of an Earth analog (at 10 pc). Differential astrometry is a very interesting tool to detect nearby habitable exoplanets. Indeed, for F, G and K main sequence stars, the astrophysical noise is smaller than the astrometric signal, contrary to the case for radial velocities. The difficulty lies in the fact that the signal of an exo-Earth around a G type star at 10 pc is a tiny 0.3 micro arc sec, which is equivalent to a coin on the moon, seen from the Earth: the main challenge is related to instrumentation. In order to reach this specification, NEAT consists of two formation flying spacecraft at a 40m distance, one carries the mirror and the other one the focal plane. Thus NEAT has a configuration with only one optical surface: an off-axis parabola. Consequently, beamwalk errors are common to the whole field of view and have a small effect on differential astrometry. Moreover a metrology system projects young fringes on the focal plane, which can characterize the pixels whenever necessary during the mission. NEAT has two main scientific objectives: combined with

  3. Dual-detection confocal fluorescence microscopy: fluorescence axial imaging without axial scanning.

    Science.gov (United States)

    Lee, Dong-Ryoung; Kim, Young-Duk; Gweon, Dae-Gab; Yoo, Hongki

    2013-07-29

    We propose a new method for high-speed, three-dimensional (3-D) fluorescence imaging, which we refer to as dual-detection confocal fluorescence microscopy (DDCFM). In contrast to conventional beam-scanning confocal fluorescence microscopy, where the focal spot must be scanned either optically or mechanically over a sample volume to reconstruct a 3-D image, DDCFM can obtain the depth of a fluorescent emitter without depth scanning. DDCFM comprises two photodetectors, each with a pinhole of different size, in the confocal detection system. Axial information on fluorescent emitters can be measured by the axial response curve through the ratio of intensity signals. DDCFM can rapidly acquire a 3-D fluorescent image from a single two-dimensional scan with less phototoxicity and photobleaching than confocal fluorescence microscopy because no mechanical depth scans are needed. We demonstrated the feasibility of the proposed method by phantom studies.

  4. Development of the present reference fracture toughness curves in the ASME nuclear code

    International Nuclear Information System (INIS)

    Yukawa, S.; Merkle, J.G.

    1984-01-01

    Since the early 1970's, the Sections of the ASME Boiler and Pressure Vessel Code concerned with nuclear power plant components have included fracture mechanics procedures to analyze the effects of postulated or detected flaws. These procedures are contained in Appendix G of Section III and in Appendix A of Section XI of the Code. Specifically, Appendix G procedures are concerned with designing for protection against nonductile failures while Appendix A procedures are for evaluating the disposition of flaws detected during in-service inspection. An important element of the procedures is the inclusion of recommended material fracture toughness values. This paper describes the origin and development of these recommended fracture toughness values. Since these values appear in the Code in a graphical format, the values are often referred to as reference toughness curves. In the context of Code terminology, reference toughness means the allowable values of fracture toughness for the materials of concern that can be used in conjunction with the analytical procedures of Appendices G and A. The paper discusses the basis and rationale underlying the original formulation of these reference toughness curves and the modifications incorporated into them in the course of their adoption into the Code

  5. Multielement comparison of instrumental neutron activation analysis techniques using reference materials

    International Nuclear Information System (INIS)

    Ratner, R.T.; Vernetson, W.G.

    1995-01-01

    Several instrumental neutron activation analysis techniques (parametric, comparative, and k o -standardization) are evaluated using three reference materials. Each technique is applied to National Institute of Standards and Technology standard reference materials, SRM 1577a (Bovine Liver) and SRM 2704 (Buffalo River Sediment), and the United States Geological Survey standard BHVO-1 (Hawaiian Basalt Rock). Identical (but not optimum) irradiation, decay, and counting schemes are employed with each technique to provide a basis for comparison and to determine sensitivities in a routine irradiation scheme. Fifty-one elements are used in this comparison; however, several elements are not detected in the reference materials due to rigid analytical conditions (e.g. insufficient length of irradiation or activity for radioisotope of interest decaying below the lower limit of detection before counting interval). Most elements are normally distributed around certified or consensus values with a standard deviation of 10%. For some elements, discrepancies are observed and discussed. The accuracy, precision, and sensitivity of each technique are discussed by comparing the analytical results to consensus values for the Hawaiian Basalt Rock to demonstrate the diversity of multielement applications. (author) 4 refs.; 2 tabs

  6. Morphology and astrometry of Infrared-Faint Radio Sources

    Science.gov (United States)

    Middelberg, Enno; Norris, Ray; Randall, Kate; Mao, Minnie; Hales, Christopher

    2008-10-01

    Infrared-Faint Radio Sources, or IFRS, are an unexpected class of object discovered in the Australia Telescope Large Area Survey, ATLAS. They are compact 1.4GHz radio sources with no visible counterparts in co-located (relatively shallow) Spitzer infrared and optical images. We have detected two of these objects with VLBI, indicating the presence of an AGN. These observations and our ATLAS data indicate that IFRS are extended on scales of arcseconds, and we wish to image their morphologies to obtain clues about their nature. These observations will also help us to select optical counterparts from very deep, and hence crowded, optical images which we have proposed. With these data in hand, we will be able to compare IFRS to known object types and to apply for spectroscopy to obtain their redshifts.

  7. Development and application of a general plasmid reference material for GMO screening.

    Science.gov (United States)

    Wu, Yuhua; Li, Jun; Wang, Yulei; Li, Xiaofei; Li, Yunjing; Zhu, Li; Li, Jun; Wu, Gang

    The use of analytical controls is essential when performing GMO detection through screening tests. Additionally, the presence of taxon-specific sequences is analyzed mostly for quality control during GMO detection. In this study, 11 commonly used genetic elements involving three promoters (P-35S, P-FMV35S and P-NOS), four marker genes (Bar, NPTII, HPT and Pmi), and four terminators (T-NOS, T-35S, T-g7 and T-e9), together with the reference gene fragments from six major crops of maize, soybean, rapeseed, rice, cotton and wheat, were co-integrated into the same single plasmid to construct a general reference plasmid pBI121-Screening. The suitability test of pBI121-Screening plasmid as reference material indicated that the non-target sequence on the pBI121-Screening plasmid did not affect the PCR amplification efficiencies of screening methods and taxon-specific methods. The sensitivity of screening and taxon-specific assays ranged from 5 to 10 copies of pBI121-Screening plasmid, meeting the sensitivity requirement of GMO detection. The construction of pBI121-Screening solves the lack of a general positive control for screening tests, thereby reducing the workload and cost of preparing a plurality of the positive control. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Age-specific reference ranges of serum prostate-specific antigen in Iranian men

    Directory of Open Access Journals (Sweden)

    Gholamreza Pourmand

    2015-08-01

    Conclusion: Findings of the present study showed that PSA levels are correlated with age. It was also revealed that the PSA age-specific reference range obtained in this study is different from other races and is specific to Iranian men. Therefore, age-specific reference ranges of PSA obtained in the present study can increase PSA test sensitivity and specificity by reducing unnecessary diagnostic procedures and early detection of prostate cancer in Iranian men.

  9. Spins, shapes, and orbits for potentially hazardous near-earth objects by NEON

    DEFF Research Database (Denmark)

    Muinonen, K.; Jørgensen, U.G.

    2006-01-01

    radiative transfer, scattering, celestial mechanics, methods: analytical, methods: data analysis, methods: numerical, methods: statistical, techniques: photometric, astrometry, comets: general, minor planets, asteroids......radiative transfer, scattering, celestial mechanics, methods: analytical, methods: data analysis, methods: numerical, methods: statistical, techniques: photometric, astrometry, comets: general, minor planets, asteroids...

  10. [Detection of Entamoeba histolytica and Entamoeba dispar by PCR in children, less than five years of age with diarrhea, in Maracaibo, Venezuela. A preliminary study].

    Science.gov (United States)

    Bracho Mora, Angela; Rivero de Rodríguez, Zulbey; Arraiz, Nailet; Villalobos, Rafael; Urdaneta, Haydee

    2013-12-01

    To determine the prevalence of Entamoeba histolytica as a producer of diarrhea, a study was conducted in children, less than five years of age, with diarrhea who attended several out patient clinics of the Servicio Aut6nomo Hospital Universitario, Maracaibo, Venezuela. A macroscopic and microscopic examination with physiological saline, lugol and Kinyoun staining were performed to the stool samples obtained. The remainder of the sample was frozen until DNA extraction, and PCR amplification was performed separately for E. histolytica and E. dispar. Microscopic examination showed no trophozoites and/or cysts of Entamoeba histolytica/dispar/moshkovskii, or intestinal coccidians in any of the 50 samples analyzed. Parasites detected were Giardia lamblia (6%), Blastocystis sp. (4%), Pentatrichomonas hominis (2%), Ascaris lumbricoides (2%) and Trichuris trichiura (2%). By PCR, six samples (12%) had DNA of E. dispar and two (4%) had DNA from E. histolytica; no child showed association of both amoebae. The two children who had E. histolytica were one-year-old. E. dispar was detected in younger children. We suggest that the prevalence of E. histolytica in children under five years is really low.

  11. A 3000 TNOs Survey Project at ESO La Silla

    Science.gov (United States)

    Boehnhardt, H.; Hainaut, O.

    We propose a wide-shallow TNO search to be done with the Wide Field Imager (WFI) instrument at the 2.2m MPG/ESO telescope in La Silla/Chile. The WFI is a half-deg camera equipped with an 8kx8k CCD (0.24 arcsec/pixel). The telescope can support excellent seeing quality down to 0.5arcsec FWHM. A TNO search pilot project was run with the 2.2m+WFI in 1999: images with just 1.6sdeg sky coverage and typically 24mag limiting brightness revealed 6 new TNOs when processed with our new automatic detection program MOVIE. The project is now continued on a somewhat larger scale in order to find more TNOs and to fine-tune the operational environment for a full automatic on-line detection, astrometry and photometry of the objects at the telescope. The future goal is to perform - with the 2.2m+WFI and in an international colaboration - an even larger TNO survey over a major part of the sky (typically 2000sdeg in and out of Ecliptic) down to 24mag. Follow-up astrometry and photometry of the expected more than 3000 discovered objects will secure their orbital and physical characterisation for synoptic dynamical and taxonomic studies of the Transneptunian population.

  12. Health-related physical fitness measures: reference values and reference equations for use in clinical practice.

    Science.gov (United States)

    Tveter, Anne Therese; Dagfinrud, Hanne; Moseng, Tuva; Holm, Inger

    2014-07-01

    To provide reference values and reference equations for frequently used clinical field tests of health-related physical fitness for use in clinical practice. Cross-sectional design. General community. Convenience sample of volunteers (N=370) between 18 and 90 years of age were recruited from a wide range of settings (ie, work sites, schools, community centers for older adults) and different geographic locations (ie, urban, suburban, rural) in southeastern Norway. Not applicable. The participants conducted 5 clinical field tests (6-minute walk test, stair test, 30-second sit-to-stand test, handgrip test, fingertip-to-floor test). The results of the field tests showed that performance remained unchanged until approximately 50 years of age; after that, performance deteriorated with increasing age. Grip strength (79%), meters walked in 6 minutes (60%), and seconds used on the stair test (59%) could be well predicted by age, sex, height, and weight in participants ≥50 years of age, whereas the performance on all tests was less well predicted in participants clinical practice. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  13. The utility of optical detection system (qPCR) and bioinformatics methods in reference gene expression analysis

    Science.gov (United States)

    Skarzyńska, Agnieszka; Pawełkowicz, Magdalena; PlÄ der, Wojciech; Przybecki, Zbigniew

    2016-09-01

    Real-time quantitative polymerase chain reaction is consider as the most reliable method for gene expression studies. However, the expression of target gene could be misinterpreted due to improper normalization. Therefore, the crucial step for analysing of qPCR data is selection of suitable reference genes, which should be validated experimentally. In order to choice the gene with stable expression in the designed experiment, we performed reference gene expression analysis. In this study genes described in the literature and novel genes predicted as control genes, based on the in silico analysis of transcriptome data were used. Analysis with geNorm and NormFinder algorithms allow to create the ranking of candidate genes and indicate the best reference for flower morphogenesis study. According to the results, genes CACS and CYCL were characterised the most stable expression, but the least suitable genes were TUA and EF.

  14. Evaluation of candidate reference genes for normalization of quantitative RT-PCR in soybean tissues under various abiotic stress conditions.

    Directory of Open Access Journals (Sweden)

    Dung Tien Le

    Full Text Available Quantitative RT-PCR can be a very sensitive and powerful technique for measuring differential gene expression. Changes in gene expression induced by abiotic stresses are complex and multifaceted, which make determining stably expressed genes for data normalization difficult. To identify the most suitable reference genes for abiotic stress studies in soybean, 13 candidate genes collected from literature were evaluated for stability of expression under dehydration, high salinity, cold and ABA (abscisic acid treatments using delta CT and geNorm approaches. Validation of reference genes indicated that the best reference genes are tissue- and stress-dependent. With respect to dehydration treatment, the Fbox/ABC, Fbox/60s gene pairs were found to have the highest expression stability in the root and shoot tissues of soybean seedlings, respectively. Fbox and 60s genes are the most suitable reference genes across dehydrated root and shoot tissues. Under salt stress the ELF1b/IDE and Fbox/ELF1b are the most stably expressed gene pairs in roots and shoots, respectively, while 60s/Fbox is the best gene pair in both tissues. For studying cold stress in roots or shoots, IDE/60s and Fbox/Act27 are good reference gene pairs, respectively. With regard to gene expression analysis under ABA treatment in either roots, shoots or across these tissues, 60s/ELF1b, ELF1b/Fbox and 60s/ELF1b are the most suitable reference genes, respectively. The expression of ELF1b/60s, 60s/Fbox and 60s/Fbox genes was most stable in roots, shoots and both tissues, respectively, under various stresses studied. Among the genes tested, 60s was found to be the best reference gene in different tissues and under various stress conditions. The highly ranked reference genes identified from this study were proved to be capable of detecting subtle differences in expression rates that otherwise would be missed if a less stable reference gene was used.

  15. Growth references

    NARCIS (Netherlands)

    Buuren, S. van

    2007-01-01

    A growth reference describes the variation of an anthropometric measurement within a group of individuals. A reference is a tool for grouping and analyzing data and provides a common basis for comparing populations.1 A well known type of reference is the age-conditional growth diagram. The

  16. Single particle detecting telescope system

    International Nuclear Information System (INIS)

    Yamamoto, I.; Tomiyama, T.; Iga, Y.; Komatsubara, T.; Kanada, M.; Yamashita, Y.; Wada, T.; Furukawa, S.

    1981-01-01

    We constructed the single particle detecting telescope system for detecting a fractionally charged particle. The telescope consists of position detecting counters, wall-less multi-cell chambers, single detecting circuits and microcomputer system as data I/0 processor. Especially, a frequency of double particle is compared the case of the single particle detecting with the case of an ordinary measurement

  17. Micro-electro-fluidic grids for nematodes: a lens-less, image-sensor-less approach for on-chip tracking of nematode locomotion.

    Science.gov (United States)

    Liu, Peng; Martin, Richard J; Dong, Liang

    2013-02-21

    This paper reports on the development of a lens-less and image-sensor-less micro-electro-fluidic (MEF) approach for real-time monitoring of the locomotion of microscopic nematodes. The technology showed promise for overcoming the constraint of the limited field of view of conventional optical microscopy, with relatively low cost, good spatial resolution, and high portability. The core of the device was microelectrode grids formed by orthogonally arranging two identical arrays of microelectrode lines. The two microelectrode arrays were spaced by a microfluidic chamber containing a liquid medium of interest. As a nematode (e.g., Caenorhabditis elegans) moved inside the chamber, the invasion of part of its body into some intersection regions between the microelectrodes caused changes in the electrical resistance of these intersection regions. The worm's presence at, or absence from, a detection unit was determined by a comparison between the measured resistance variation of this unit and a pre-defined threshold resistance variation. An electronic readout circuit was designed to address all the detection units and read out their individual electrical resistances. By this means, it was possible to obtain the electrical resistance profile of the whole MEF grid, and thus, the physical pattern of the swimming nematode. We studied the influence of a worm's body on the resistance of an addressed unit. We also investigated how the full-frame scanning and readout rates of the electronic circuit and the dimensions of a detection unit posed an impact on the spatial resolution of the reconstructed images of the nematode. Other important issues, such as the manufacturing-induced initial non-uniformity of the grids and the electrotaxic behaviour of nematodes, were also studied. A drug resistance screening experiment was conducted by using the grids with a good resolution of 30 × 30 μm(2). The phenotypic differences in the locomotion behaviours (e.g., moving speed and oscillation

  18. Detection Range of Airborne Magnetometers in Magnetic Anomaly Detection

    Directory of Open Access Journals (Sweden)

    Chengjing Li

    2015-11-01

    Full Text Available Airborne magnetometers are utilized for the small-range search, precise positioning, and identification of the ferromagnetic properties of underwater targets. As an important performance parameter of sensors, the detection range of airborne magnetometers is commonly set as a fixed value in references regardless of the influences of environment noise, target magnetic properties, and platform features in a classical model to detect airborne magnetic anomalies. As a consequence, deviation in detection ability analysis is observed. In this study, a novel detection range model is proposed on the basis of classic detection range models of airborne magnetometers. In this model, probability distribution is applied, and the magnetic properties of targets and the environment noise properties of a moving submarine are considered. The detection range model is also constructed by considering the distribution of the moving submarine during detection. A cell-averaging greatest-of-constant false alarm rate test method is also used to calculate the detection range of the model at a desired false alarm rate. The detection range model is then used to establish typical submarine search probabilistic models. Results show that the model can be used to evaluate not only the effects of ambient magnetic noise but also the moving and geomagnetic features of the target and airborne detection platform. The model can also be utilized to display the actual operating range of sensor systems.

  19. Oracle Data Dictionary Pocket Reference

    CERN Document Server

    Kreines, David

    2003-01-01

    If you work with Oracle, then you don't need to be told that the data dictionary is large and complex, and grows larger with each new Oracle release. It's one of the basic elements of the Oracle database you interact with regularly, but the sheer number of tables and views makes it difficult to remember which view you need, much less the name of the specific column. Want to make it simpler? The Oracle Data Dictionary Pocket Reference puts all the information you need right at your fingertips. Its handy and compact format lets you locate the table and view you need effortlessly without stoppin

  20. Digital imaging using storage phosphor screens a film-less procedure to detect radiation

    International Nuclear Information System (INIS)

    Narayana Rao, A.V.S.S.; Mahajan, S.K.

    1998-01-01

    The imaging plate is a film-like radiation sensor comprising of specifically designed phosphors (photostimulable storage phosphors) that trap and store energy resulting from the decay of radioactive atoms in the sample. In a typical setup, samples containing radioactivity are placed next to the imaging plate for a duration of about 5-10 times less than that is needed for normal x-ray films. The stored energy is stable until scanned with a laser beam, which releases the energy as luminescence. Digital signal processing of the emitted light results in an image which represents a quantitative measure of the activity of the radiolabeled sample. This phosphor technology, launched in its first application to the medical x-ray diagnostic field, portends great promise in a wide range of newer scientific and technological applications. (author)

  1. Personal Computer-less (PC-less) Microcontroller Training Kit

    Science.gov (United States)

    Somantri, Y.; Wahyudin, D.; Fushilat, I.

    2018-02-01

    The need of microcontroller training kit is necessary for practical work of students of electrical engineering education. However, to use available training kit not only costly but also does not meet the need of laboratory requirements. An affordable and portable microcontroller kit could answer such problem. This paper explains the design and development of Personal Computer Less (PC-Less) Microcontroller Training Kit. It was developed based on Lattepanda processor and Arduino microcontroller as target. The training kit equipped with advanced input-output interfaces that adopted the concept of low cost and low power system. The preliminary usability testing proved this device can be used as a tool for microcontroller programming and industrial automation training. By adopting the concept of portability, the device could be operated in the rural area which electricity and computer infrastructure are limited. Furthermore, the training kit is suitable for student of electrical engineering student from university and vocational high school.

  2. Perpendicular magnetic tunnel junction with thin CoFeB/Ta/Co/Pd/Co reference layer

    Energy Technology Data Exchange (ETDEWEB)

    Gan, Huadong, E-mail: huadong@avalanche-technology.com; Malmhall, Roger; Wang, Zihui; Yen, Bing K; Zhang, Jing; Wang, Xiaobin; Zhou, Yuchen; Hao, Xiaojie; Jung, Dongha; Satoh, Kimihiro; Huai, Yiming [Avalanche Technology, 46600 Landing Parkway, Fremont, California 94538 (United States)

    2014-11-10

    Integration of high density spin transfer torque magnetoresistance random access memory requires a thin stack (less than 15 nm) of perpendicular magnetic tunnel junction (p-MTJ). We propose an innovative approach to solve this challenging problem by reducing the thickness and/or moment of the reference layer. A thin reference layer structure of CoFeB/Ta/Co/Pd/Co has 60% magnetic moment of the conventional thick structure including [Co/Pd] multilayers. We demonstrate that the perpendicular magnetization of the CoFeB/Ta/Co/Pd/Co structure can be realized by anti-ferromagnetically coupling to a pinned layer with strong perpendicular anisotropy via Ruderman-Kittel-Kasuya-Yosida exchange interaction. The pMTJ with thin CoFeB/Ta/Co/Pd/Co reference layer has a comparable TMR ratio (near 80%) as that with thick reference layer after annealing at 280 °C. The pMTJ with thin reference layer has a total thickness less than 15 nm, thereby significantly increasing the etching margin required for integration of high density pMTJ array on wafers with form factor of 300 mm and beyond.

  3. Recent references

    International Nuclear Information System (INIS)

    Ramavataram, S.

    1991-01-01

    In support of a continuing program of systematic evaluation of nuclear structure data, the National Nuclear Data Center maintains a complete computer file of references to the nuclear physics literature. Each reference is tagged by a keyword string, which indicates the kinds of data contained in the article. This master file of Nuclear Structure References (NSR) contains complete keyword indexes to literature published since 1969, with partial indexing of older references. Any reader who finds errors in the keyword descriptions is urged to report them to the National Nuclear Data Center so that the master NSR file can be corrected. In 1966, the first collection of Recent References was published as a separate issue of Nuclear Data Sheets. Every four months since 1970, a similar indexed bibliography to new nuclear experiments has been prepared from additions to the NSR file and published. Beginning in 1978, Recent References was cumulated annually, with the third issue completely superseding the two issues previously published during a given year. Due to publication policy changes, cumulation of Recent Reference was discontinued in 1986. The volume and issue number of all the cumulative issues published to date are given. NNDC will continue to respond to individual requests for special bibliographies on nuclear physics topics, in addition to those easily obtained from Recent References. If the required information is available from the keyword string, a reference list can be prepared automatically from the computer files. This service can be provided on request, in exchange for the timely communication of new nuclear physics results (e.g., preprints). A current copy of the NSR file may also be obtained in a standard format on magnetic tape from NNDC. Requests for special searches of the NSR file may also be directed to the National Nuclear Data Center

  4. Micellar Liquid Chromatography for the Determination of Some Less Prescribed Benzodiazepines

    Directory of Open Access Journals (Sweden)

    Hoonka Subhra

    2012-01-01

    Full Text Available A simple chromatographic procedure is reported for the determination of some less prescribed but equally important benzodiazepines (Clotiazepam, clozapine and pinazepam in serum. The optimization studies have been made in CN, C18 and C8 columns, using mobile phase containing sodium dodecyl sulphate (SDS modified with either propanol, butanol or pentanol. The method proposed for the determination of the three benzodiazepines using a mobile phase of 0.13 M SDS, 2.4% pentanol-0.01 M phosphate buffer- 0.1% triethylamine (pH 7 at 25°C and UV detection (240 nm in a C8 column. The serum samples was injected directly, without any pretreatment, eluted in less than 8 min, in accordance to their relative polarities, as indicated by their octanol-water partition coefficients. The limits of detection (ng/mL was in the 1.6 to 5.6 and 7 to 87 range, for aqueous and serum samples, respectively. Repeatability and intermediate precision was tested for three different concentrations of the drugs, resulting in the 0.1 to 2 range. The results obtained here for the separation of the three benzodiazepines in serum were also counter checked at Department of Bio-analytical Chemistry, Universitat Jaume I, Castelló, Spain.

  5. Less Smart More City

    Directory of Open Access Journals (Sweden)

    Rocco Papa

    2015-07-01

    Full Text Available Smart is an expression used in recent years in science, and it refers to someone or something that shows a lively intelligence, with a quick learning curve and a fast response to external stimuli. The present scenario is dominated by the accelerated technological development that involves every aspect of life, enhancing the everyday tools through the use of information and digital processing: everything is smart, even cities. But when you pair the term smart to a complex organism such as the city the significance of the two together is open to a variety of interpretations, as shown by the vast and varied landscape of definitions that have occurred in recent years. Our contribution presents the results of research aimed at analyzing and interpreting this fragmented scene mainly, but not exclusively, through lexical analysis, applied to a textual corpus of 156 definitions of smart city. In particular, the study identified the main groups of stakeholders that have taken part in the debate, and investigated the differences and convergences that can be detected: Academic, Institutional, and Business worlds. It is undeniable that the term smart has been a veritable media vehicle that, on the one hand brought to the center of the discussion the issue of the city, of increasing strategic importance for the major challenges that humanity is going to face,  and on the other has been a fertile ground on which to pour the interests of different groups and individuals. In a nutshell we can say that from the analysis the different approaches that each group has used and supported emerge clearly and another, alarming, consideration occurs: of the smart part of “Smart City” we clearly grasp the tools useful to the each group of stakeholders, and of the city part, as a collective aspiration, there is often little or nothing.

  6. Contact with Counter-Stereotypical Women Predicts Less Sexism, Less Rape Myth Acceptance, Less Intention to Rape (in Men) and Less Projected Enjoyment of Rape (in Women).

    Science.gov (United States)

    Taschler, Miriam; West, Keon

    2017-01-01

    Intergroup contact-(positive) interactions with people from different social groups-is a widely researched and strongly supported prejudice-reducing mechanism shown to reduce prejudice against a wide variety of outgroups. However, no known previous research has investigated whether intergroup contact can also reduce sexism against women. Sexism has an array of negative outcomes. One of the most detrimental and violent ones is rape, which is both justified and downplayed by rape myth acceptance. We hypothesised that more frequent, higher quality contact with counter-stereotypical women would predict lower levels of sexism and thus less rape myth acceptance (in men) and less sexualised projected responses to rape (in women). Two studies using online surveys with community samples supported these hypotheses. In Study 1, 170 male participants who experienced more positive contact with counter-stereotypical women reported less intention to rape. Similarly, in Study 2, 280 female participants who experienced more positive contact with counter-stereotypical women reported less projected sexual arousal at the thought of being raped. Thus, the present research is the first known to show that contact could be a potential tool to combat sexism, rape myth acceptance, intentions to rape in men, and sexualisation of rape by women.

  7. Stored object knowledge and the production of referring expressions: The case of color typicality

    Directory of Open Access Journals (Sweden)

    Hans eWesterbeek

    2015-07-01

    Full Text Available When speakers describe objects with atypical properties, do they include these properties in their referring expressions, even when that is not strictly required for unique referent identification? Based on previous work, we predict that speakers mention the color of a target object more often when the object is atypically colored, compared to when it is typical. Taking literature from object recognition and visual attention into account, we further hypothesize that this behavior is proportional to the degree to which a color is atypical, and whether color is a highly diagnostic feature in the referred-to object's identity. We investigate these expectations in two language production experiments, in which participants referred to target objects in visual contexts. In Experiment 1, we find a strong effect of color typicality: less typical colors for target objects predict higher proportions of referring expressions that include color. In Experiment 2 we manipulated objects with more complex shapes, for which color is less diagnostic, and we find that the color typicality effect is moderated by color diagnosticity: it is strongest for high-color-diagnostic objects (i.e., objects with a simple shape. These results suggest that the production of atypical color attributes results from a contrast with stored knowledge, an effect which is stronger when color is more central to object identification. Our findings offer evidence for models of reference production that incorporate general object knowledge, in order to be able to capture these effects of typicality on determining the content of referring expressions.

  8. Astrometry of red supergiant VY Canis Majoris with VERA

    Science.gov (United States)

    Choi, Y. K.; Hirota, T.; Honma, M.; Kobayashi, H.

    2008-07-01

    We present observational results on the red supergiant VY Canis Majoris with VERA. We have observed 22 GHz H2O masers and 43 GHz SiO masers (v=1 and 2 J=1-0) around VY CMa for 13 months. We succesfully detected a parallax of 0.87 ± 0.08 mas, corresponding to the distance of 1.15 +0.10-0.09 kpc using H2O masers. As the result of phase-referencing analyses, we have measured absolute positions for both H2O masers and SiO masers. The H2O maser features show rapid expansion off the central star.

  9. User satisfaction with referrals at a collaborative virtual reference service Virtual reference services, Reference services, Referrals, User satisfaction

    Directory of Open Access Journals (Sweden)

    Nahyun Kwon

    2006-01-01

    Full Text Available Introduction. This study investigated unmonitored referrals in a nationwide, collaborative chat reference service. Specifically, it examined the extent to which questions are referred, the types of questions that are more likely to be referred than others, and the level of user satisfaction with the referrals in the collaborative chat reference service. Method. The data analysed for this study were 420 chat reference transaction transcripts along with corresponding online survey questionnaires submitted by the service users. Both sets of data were collected from an electronic archive of a southeastern state public library system that has participated in 24/7 Reference of the Metropolitan Cooperative Library System (MCLS. Results. Referrals in the collaborative chat reference service comprised approximately 30% of the total transactions. Circulation-related questions were the most often referred among all question types, possibly because of the inability of 'outside' librarians to access patron accounts. Most importantly, user satisfaction with referrals was found to be significantly lower than that of completed answers. Conclusion. The findings of this study addressed the importance of distinguishing two types of referrals: the expert research referrals conducive to collaborative virtual reference services; and the re-directional local referrals that increase unnecessary question traffic, thereby being detrimental to effective use of collaborative reference. Continuing efforts to conceptualize referrals in multiple dimensions are anticipated to fully grasp complex phenomena underlying referrals.

  10. A novel technique for detection efficiency determination of HPGe

    International Nuclear Information System (INIS)

    Tayyebi, Pouneh; Abbasi Davani, Fereydoun; Tabasi, Mohsen; Afarideh, Hossein

    2017-01-01

    In this work, we present an experimental method to determine the detection efficiency of HPGe when the reference source according to the geometry of interest is not accessible. We use known activity point sources (PS) of 152 Eu, 137 Cs, 241 Am and 133 Ba to find the detection efficiency for disc source (DS) geometry. It can be assumed that a DS consists of several PS's. Mapping the detector surface by means of 137 Cs PS shows that there is radial symmetry for detection efficiency vs. energy. Each radial distance on the detector surface contains some points, which can be considered as a PS. By selecting two points in two different radii and central point, the DS efficiency is obtained. To ensure that the method is correct, we measure the activity of a known activity DS considering DS efficiency obtained by PS's. The DS comprises 137 Cs, 133 Ba and 60 Co. The relative difference between the measured and the reported activity of DS in most energies is less than 5%. - Highlights: • Exact knowledge of the detector dimension is not necessary • There is no need to have standard source according to the sample • It is a simple method that can be done at any laboratories

  11. The cost of model reference adaptive control - Analysis, experiments, and optimization

    Science.gov (United States)

    Messer, R. S.; Haftka, R. T.; Cudney, H. H.

    1993-01-01

    In this paper the performance of Model Reference Adaptive Control (MRAC) is studied in numerical simulations and verified experimentally with the objective of understanding how differences between the plant and the reference model affect the control effort. MRAC is applied analytically and experimentally to a single degree of freedom system and analytically to a MIMO system with controlled differences between the model and the plant. It is shown that the control effort is sensitive to differences between the plant and the reference model. The effects of increased damping in the reference model are considered, and it is shown that requiring the controller to provide increased damping actually decreases the required control effort when differences between the plant and reference model exist. This result is useful because one of the first attempts to counteract the increased control effort due to differences between the plant and reference model might be to require less damping, however, this would actually increase the control effort. Optimization of weighting matrices is shown to help reduce the increase in required control effort. However, it was found that eventually the optimization resulted in a design that required an extremely high sampling rate for successful realization.

  12. [Reference citation].

    Science.gov (United States)

    Brkić, Silvija

    2013-01-01

    Scientific and professional papers represent the information basis for scientific research and professional work. References important for the paper should be cited within the text, and listed at the end of the paper. This paper deals with different styles of reference citation. Special emphasis was placed on the Vancouver Style for reference citation in biomedical journals established by the International Committee of Medical Journal Editors. It includes original samples for citing various types of articles, both printed and electronic, as well as recommendations related to reference citation in accordance with the methodology and ethics of scientific research and guidelines for preparing manuscripts for publication.

  13. Haematological and biochemical reference intervals for free-ranging brown bears (Ursus arctos) in Sweden

    DEFF Research Database (Denmark)

    Græsli, Anne Randi; Fahlman, Åsa; Evans, Alina L.

    2014-01-01

    BackgroundEstablishment of haematological and biochemical reference intervals is important to assess health of animals on individual and population level. Reference intervals for 13 haematological and 34 biochemical variables were established based on 88 apparently healthy free-ranging brown bears...... and marking for ecological studies. For each of the variables, the reference interval was described based on the 95% confidence interval, and differences due to host characteristics sex and age were included if detected. To our knowledge, this is the first report of reference intervals for free-ranging brown...... and the differences due to host factors age and gender can be useful for evaluation of health status in free-ranging European brown bears....

  14. Multipath ultrasonic gas flow-meter based on multiple reference waves.

    Science.gov (United States)

    Zhou, Hongliang; Ji, Tao; Wang, Ruichen; Ge, Xiaocheng; Tang, Xiaoyu; Tang, Shizhen

    2018-01-01

    Several technologies can be used in ultrasonic gas flow-meters, such as transit-time, Doppler, cross-correlation and etc. In applications, the approach based on measuring transit-time has demonstrated its advantages and become more popular. Among those techniques which can be applied to determine time-of-flight (TOF) of ultrasonic waves, including threshold detection, cross correlation algorithm and other digital signal processing algorithms, cross correlation algorithm has more advantages when the received ultrasonic signal is severely disturbed by the noise. However, the reference wave for cross correlation computation has great influence on the precise measurement of TOF. In the applications of the multipath flow-meters, selection of the reference wave becomes even more complicated. Based on the analysis of the impact factors that will introduce noise and waveform distortion of ultrasonic waves, an averaging method is proposed to determine the reference wave in this paper. In the multipath ultrasonic gas flow-meter, the analysis of each path of ultrasound needs its own reference wave. In case study, a six-path ultrasonic gas flow-meter has been designed and tested with air flow through the pipeline. The results demonstrate that the flow rate accuracy and the repeatability of the TOF are significantly improved by using averaging reference wave, compared with that using random reference wave. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. The search for reference conditions for stream vegetation in northern Europe

    DEFF Research Database (Denmark)

    Battrup-Pedersen, Anette; Springe, G.; Riis, Tenna

    2008-01-01

    1. The European Water Framework Directive provides a framework for improving the ecological quality of stream ecosystems, with deviation from reference used as a measure of ecological status. 2. Here we examine the possibility of using less impacted stream sites from Latvia, Lithuania and Poland...

  16. Targeted liquid chromatography tandem mass spectrometry to quantitate wheat gluten using well-defined reference proteins

    Science.gov (United States)

    Schalk, Kathrin; Koehler, Peter

    2018-01-01

    Celiac disease (CD) is an inflammatory disorder of the upper small intestine caused by the ingestion of storage proteins (prolamins and glutelins) from wheat, barley, rye, and, in rare cases, oats. CD patients need to follow a gluten-free diet by consuming gluten-free products with gluten contents of less than 20 mg/kg. Currently, the recommended method for the quantitative determination of gluten is an enzyme-linked immunosorbent assay (ELISA) based on the R5 monoclonal antibody. Because the R5 ELISA mostly detects the prolamin fraction of gluten, a new independent method is required to detect prolamins as well as glutelins. This paper presents the development of a method to quantitate 16 wheat marker peptides derived from all wheat gluten protein types by liquid chromatography tandem mass spectrometry (LC-MS/MS) in the multiple reaction monitoring mode. The quantitation of each marker peptide in the chymotryptic digest of a defined amount of the respective reference wheat protein type resulted in peptide-specific yields. This enabled the conversion of peptide into protein type concentrations. Gluten contents were expressed as sum of all determined protein type concentrations. This new method was applied to quantitate gluten in wheat starches and compared to R5 ELISA and gel-permeation high-performance liquid chromatography with fluorescence detection (GP-HPLC-FLD), which resulted in a strong correlation between LC-MS/MS and the other two methods. PMID:29425234

  17. Targeted liquid chromatography tandem mass spectrometry to quantitate wheat gluten using well-defined reference proteins.

    Directory of Open Access Journals (Sweden)

    Kathrin Schalk

    Full Text Available Celiac disease (CD is an inflammatory disorder of the upper small intestine caused by the ingestion of storage proteins (prolamins and glutelins from wheat, barley, rye, and, in rare cases, oats. CD patients need to follow a gluten-free diet by consuming gluten-free products with gluten contents of less than 20 mg/kg. Currently, the recommended method for the quantitative determination of gluten is an enzyme-linked immunosorbent assay (ELISA based on the R5 monoclonal antibody. Because the R5 ELISA mostly detects the prolamin fraction of gluten, a new independent method is required to detect prolamins as well as glutelins. This paper presents the development of a method to quantitate 16 wheat marker peptides derived from all wheat gluten protein types by liquid chromatography tandem mass spectrometry (LC-MS/MS in the multiple reaction monitoring mode. The quantitation of each marker peptide in the chymotryptic digest of a defined amount of the respective reference wheat protein type resulted in peptide-specific yields. This enabled the conversion of peptide into protein type concentrations. Gluten contents were expressed as sum of all determined protein type concentrations. This new method was applied to quantitate gluten in wheat starches and compared to R5 ELISA and gel-permeation high-performance liquid chromatography with fluorescence detection (GP-HPLC-FLD, which resulted in a strong correlation between LC-MS/MS and the other two methods.

  18. The impact of different reference panels on spectral reflectance coefficients of some biological water pollutants

    Science.gov (United States)

    Jenerowicz, Agnieszka; Walczykowski, Piotr

    2015-10-01

    Monitoring of water environment and ecosystem, detecting water contaminants and understanding water quality parameters are most important tasks in water management and protection of whole aquatic environment. Detection of biological contaminants play a very important role in preserving human health and water management. To obtain accurate and precise results of determination of the level of biological contamination and to distinguish its type it is necessary to determine precisely spectral reflectance coefficients of several water biological pollutants with inter alia spectroradiometer. This paper presents a methodology and preliminary results of acquisition of spectral reflectance coefficients with different reference panels (e.g. with 5%, 20%, 50%, 80% and 96% of reflectivity) of several biological pollutants. The authors' main task was to measure spectral reflectance coefficients of different biological water pollutants with several reference panels and to select optimal reference standard, which would allow for distinguish different types of several biological contaminants. Moreover it was necessary to indicate the spectral range in which it is possible to discriminate investigated samples of biological contaminants. By conducting many series of measurements of several samples of different types of biological pollutants, authors had concluded how the reflectivity of reference panel influences the accuracy of acquisition of spectral reflectance coefficients. This research was crucial in order to be able to distinguish several types of biological pollutants and to determine the useful spectral range for detection of different kinds of biological contaminants with multispectral and hyperspectral imagery.

  19. A reference tristimulus colorimeter

    Science.gov (United States)

    Eppeldauer, George P.

    2002-06-01

    A reference tristimulus colorimeter has been developed at NIST with a transmission-type silicon trap detector (1) and four temperature-controlled filter packages to realize the Commission Internationale de l'Eclairage (CIE) x(λ), y(λ) and z(λ) color matching functions (2). Instead of lamp standards, high accuracy detector standards are used for the colorimeter calibration. A detector-based calibration procedure is being suggested for tristimulus colorimeters wehre the absolute spectral responsivity of the tristimulus channels is determined. Then, color (spectral) correct and peak (amplitude) normalization are applied to minimize uncertainties caused by the imperfect realizations of the CIE functions. As a result of the corrections, the chromaticity coordinates of stable light sources with different spectral power distributions can be measured with uncertainties less than 0.0005 (k=1).

  20. Who Is the Agent? The Influence of Pragmatic Leads on Children's Reference Assignment in Non-Obligatory Control

    Science.gov (United States)

    Janke, Vikki

    2018-01-01

    Non-obligatory control constructions (NOC) are sentences which contain a non-finite clause with a null subject whose reference is determined pragmatically. Little is known about how children assign reference to these subjects, yet this is important as our current understanding of reference-resolution development is limited to less complex…

  1. Improved Internal Reference Oxygen Sensors Using Composite Oxides as Electrodes

    DEFF Research Database (Denmark)

    Hu, Qiang

    The thesis describes the research on and development of an internal reference oxygen sensor (IROS). The IROS is potentiometric and uses the equilibrium pO2of the binary mixture of Ni/NiO as the reference pO2. The sensing electrode of the IROS are made from metallic Pt or the composite of (La0.75S...... the application of IROSes are provided. Based on the concepts and fundamentals of the IROS, internal reference sensors that detect other gas species such as hydrogen, chlorine and bromine may be developed.......The thesis describes the research on and development of an internal reference oxygen sensor (IROS). The IROS is potentiometric and uses the equilibrium pO2of the binary mixture of Ni/NiO as the reference pO2. The sensing electrode of the IROS are made from metallic Pt or the composite of (La0.75Sr0...... from 8YSZ is evaluated quantitatively and figures that may be used to design the depletion period of an IROS due to the electronic leak of 8YSZ are provided. One dimensional numerical simulations are performed to study the variation in cell voltage during the process of gas mixing, and the asymmetric...

  2. Learning Less.js

    CERN Document Server

    Libby, Alex

    2014-01-01

    If you are a designer or developer who wants to quickly learn how to harness the power of Less.js to write more efficient CSS styles that can be applied to a website of any size, then this book is for you. This book will help you master both the basic functions and advanced features of Less.js. It would be helpful to have some familiarity of writing CSS styles, although no prior experience of using CSS preprocessors is required.

  3. Reference amounts utilised in front of package nutrition labelling; impact on product healthfulness evaluations.

    Science.gov (United States)

    Raats, M M; Hieke, S; Jola, C; Hodgkins, C; Kennedy, J; Wills, J

    2015-05-01

    The research question addressed in this paper is how different reference amounts utilised in front of package nutrition labelling influence evaluation of product healthfulness. A total of 13,117 participants from six European countries (Germany, UK, Spain, France, Poland and Sweden) were recruited via online panels. A mixed between/within-subject factorial design was employed with food (biscuits, sandwiches, yogurts), healthfulness and presence of Guideline Daily Amounts as within-subjects factors and reference amount ('per 100 g', 'typical portion', 'half portion') and country as between-subjects factors. Overall, people correctly ranked foods according to their objective healthfulness as defined by risk nutrients alone, and could distinguish between more and less healthful variants of foods. General healthfulness associations with the three product categories do not appear to have had a strong influence on product ratings. This study shows that where the reference amount of 'per 100 g' is very different from the 'typical' portion size, as was the case for biscuits, products with a 'per 100 g' label are rated significantly less healthful than the 'typical' or 'half typical' portions. The results indicate that across the three food categories, consumers do factor the reference amount, that is, the quantity of food for which the nutritional information is being presented, into their judgements of healthfulness. Therefore, appropriate reference amounts are also of importance for the effective presentation of nutritional information.

  4. Network anomaly detection a machine learning perspective

    CERN Document Server

    Bhattacharyya, Dhruba Kumar

    2013-01-01

    With the rapid rise in the ubiquity and sophistication of Internet technology and the accompanying growth in the number of network attacks, network intrusion detection has become increasingly important. Anomaly-based network intrusion detection refers to finding exceptional or nonconforming patterns in network traffic data compared to normal behavior. Finding these anomalies has extensive applications in areas such as cyber security, credit card and insurance fraud detection, and military surveillance for enemy activities. Network Anomaly Detection: A Machine Learning Perspective presents mach

  5. Reference values for paediatric pulmonary function testing: The Utrecht dataset.

    Science.gov (United States)

    Koopman, Marije; Zanen, Pieter; Kruitwagen, Cas L J J; van der Ent, Cornelis K; Arets, Hubertus G M

    2011-01-01

    Since populations evolve, measurement protocols and equipment improve and analysis techniques progress, there is an ongoing need to reassess reference data for pulmonary function tests. Furthermore, reference values for total lung capacity and carbon monoxide diffusion capacity are scarcely available in children. We aimed to provide updated reference equations for most commonly used pulmonary function indices in Caucasian children. In the 'Utrecht Pulmonary Function Reference Data Study' we collected data in Caucasian children aged 2-18 years. We analyzed them using the 'Generalized Additive Models for Location Scale and Shape' (GAMLSS) statistical method. Measurements of interrupter resistance (R(int)) (n = 877), spirometry (n = 1042), body plethysmography (n = 723) and carbon monoxide diffusion/helium dilution (n = 543) were obtained in healthy children. Height (or the natural logarithm of height) and age (or the natural logarithm of age) were both significantly related to most outcome measures. Also sex was a significant determinant, except for RV, RV/TLC, FRC(pleth), Raw(0,5), Raw(tot), R(int) and FEF values. The application of previously published reference equations on the study population resulted in misinterpretation of pulmonary function. These new paediatric reference equations provide accurate estimates of the range of normality for most commonly used pulmonary function indices, resulting in less underdiagnosis and overdiagnosis of pulmonary diseases. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. GIER: A Danish computer from 1961 with a role in the modern revolution of astronomy - II

    Science.gov (United States)

    Høg, Erik

    2018-04-01

    A Danish computer, GIER, from 1961 played a vital role in the development of a new method for astrometric measurement. This method, photon counting astrometry, ultimately led to two satellites with a significant role in the modern revolution of astronomy. A GIER was installed at the Hamburg Observatory in 1964 where it was used to implement the entirely new method for the measurement of stellar positions by means of a meridian circle, at that time the fundamental instrument of astrometry. An expedition to Perth in Western Australia with the instrument and the computer was a success. This method was also implemented in space in the first ever astrometric satellite Hipparcos launched by ESA in 1989. The Hipparcos results published in 1997 revolutionized astrometry with an impact in all branches of astronomy from the solar system and stellar structure to cosmic distances and the dynamics of the Milky Way. In turn, the results paved the way for a successor, the one million times more powerful Gaia astrometry satellite launched by ESA in 2013. Preparations for a Gaia successor in twenty years are making progress.

  7. Performance of unbalanced QPSK in the presence of noisy reference and crosstalk

    Science.gov (United States)

    Divsalar, D.; Yuen, J. H.

    1979-01-01

    The problem of transmitting two telemetry data streams having different rates and different powers using unbalanced quadriphase shift keying (UQPSK) signaling is considered. It is noted that the presence of a noisy carrier phase reference causes a degradation in detection performance in coherent communications systems and that imperfect carrier synchronization not only attenuates the main demodulated signal voltage in UQPSK but also produces interchannel interference (crosstalk) which degrades the performance still further. Exact analytical expressions for symbol error probability of UQPSK in the presence of noise phase reference are derived.

  8. Hunter-gatherers have less famine than agriculturalists.

    Science.gov (United States)

    Berbesque, J Colette; Marlowe, Frank W; Shaw, Peter; Thompson, Peter

    2014-01-01

    The idea that hunter-gatherer societies experience more frequent famine than societies with other modes of subsistence is pervasive in the literature on human evolution. This idea underpins, for example, the 'thrifty genotype hypothesis'. This hypothesis proposes that our hunter-gatherer ancestors were adapted to frequent famines, and that these once adaptive 'thrifty genotypes' are now responsible for the current obesity epidemic. The suggestion that hunter-gatherers are more prone to famine also underlies the widespread assumption that these societies live in marginal habitats. Despite the ubiquity of references to 'feast and famine' in the literature describing our hunter-gatherer ancestors, it has rarely been tested whether hunter-gatherers suffer from more famine than other societies. Here, we analyse famine frequency and severity in a large cross-cultural database, in order to explore relationships between subsistence and famine risk. This is the first study to report that, if we control for habitat quality, hunter-gatherers actually had significantly less--not more--famine than other subsistence modes. This finding challenges some of the assumptions underlying for models of the evolution of the human diet, as well as our understanding of the recent epidemic of obesity and type 2 diabetes mellitus.

  9. Lessing und der Islam

    OpenAIRE

    Muslim, Zahim Mohammed

    2010-01-01

    Lessing und der Islam“ beschäftigt sich unparteiisch mit Lessings Auseinandersetzung mit dem Islam. Die Arbeit setzt sich das Ziel, den Leser und den Literaturkennern sowie der deutschen Bibliothek der Germanistik etwas von Lessings Auseinandersetzung mit dem Islam in die Hand zu geben, die bis heute als großes Modell für die interkulturelle und interreligiöse Menschheitstoleranzdebatte im Gedächtnis der deutschen Literatur vorhanden ist. Im ersten Teil widmet sich die vorliegende Arbeit de...

  10. Decline in Reference Transactions with Few Questions Referred to Librarian when the Reference Desk is Staffed by a Paraprofessional. A Review of: Dinkins, D., & Ryan, S. M. (2010. Measuring referrals: The use of paraprofessionals at the reference desk. The Journal of Academic Librarianship, 36(4, 279-286.

    Directory of Open Access Journals (Sweden)

    Diana K. Wakimoto

    2011-03-01

    .5% decrease in the number of reference desk transactions during the paraprofessional's hours on the desk compared to the previous year when the desk was staffed by professional librarians. Overall, reference desk transactions for all hours decreased 4.1% compared to the previous year. The results from the questionnaire on his experiences at the reference desk showed that the paraprofessional was satisfied with his training, comfortable with referring questions to the librarians, did not use the print reference collection extensively, thought the "interface for searching the library's catalogue/databases is dated at best" (p. 285, and felt that being close in age to many of the students was a disadvantage while working at the reference desk.Conclusion — The authors concluded that staffing the reference desk with a paraprofessional was a success and that the "referrals to librarians had been made appropriately and when necessary" (p. 285. The results corroborated previous studies that showed only a "small percentage of reference desk transactions would need to be referred to a librarian" (p. 285. In part, because of the success of staffing the desk with a paraprofessional, the authors suggest that reference desk staffing configurations at academic libraries should be reevaluated. Librarians freed from duties at the physical reference desk could use this time to "develop virtual reference services" and expand information literacy programs (p. 286.To explain the decrease in number of transactions during the paraprofessional's time on the reference desk, the authors surmised four possibilities: patrons' reluctance to ask questions of someone new on the desk, their dissatisfaction with the paraprofessional's answers, the similarity in age between the paraprofessional and the "age of the student population" (p. 284, or the librarians being more conscientious in tallying every transaction. However, the authors doubted that users perceived the paraprofessional's answers as "less

  11. Selection of reference genes for qPCR in hairy root cultures of peanut

    Directory of Open Access Journals (Sweden)

    Medrano Giuliana

    2011-10-01

    Full Text Available Abstract Background Hairy root cultures produced via Agrobacterium rhizogenes-mediated transformation have emerged as practical biological models to elucidate the biosynthesis of specialized metabolites. To effectively understand the expression patterns of the genes involved in the metabolic pathways of these compounds, reference genes need to be systematically validated under specific experimental conditions as established by the MIQE (Minimum Information for Publication of Quantitative Real-Time PCR Experiments guidelines. In the present report we describe the first validation of reference genes for RT-qPCR in hairy root cultures of peanut which produce stilbenoids upon elicitor treatments. Results A total of 21 candidate reference genes were evaluated. Nineteen genes were selected based on previous qPCR studies in plants and two were from the T-DNAs transferred from A. rhizogenes. Nucleotide sequences of peanut candidate genes were obtained using their homologous sequences in Arabidopsis. To identify the suitable primers, calibration curves were obtained for each candidate reference gene. After data analysis, 12 candidate genes meeting standard efficiency criteria were selected. The expression stability of these genes was analyzed using geNorm and NormFinder algorithms and a ranking was established based on expression stability of the genes. Candidate reference gene expression was shown to have less variation in methyl jasmonate (MeJA treated root cultures than those treated with sodium acetate (NaOAc. Conclusions This work constitutes the first effort to validate reference genes for RT-qPCR in hairy roots. While these genes were selected under conditions of NaOAc and MeJA treatment, we anticipate these genes to provide good targets for reference genes for hairy roots under a variety of stress conditions. The lead reference genes were a gene encoding for a TATA box binding protein (TBP2 and a gene encoding a ribosomal protein (RPL8C. A

  12. Less accurate but more efficient family of search templates for detection of gravitational waves from inspiraling compact binaries

    International Nuclear Information System (INIS)

    Chronopoulos, Andreas E.; Apostolatos, Theocharis A.

    2001-01-01

    The network of interferometric detectors that is under construction at various locations on Earth is expected to start searching for gravitational waves in a few years. The number of search templates that is needed to be cross correlated with the noisy output of the detectors is a major issue since computing power capabilities are restricted. By choosing higher and higher post-Newtonian order expansions for the family of search templates we make sure that our filters are more accurate copies of the real waves that hit our detectors. However, this is not the only criterion for choosing a family of search templates. To make the process of detection as efficient as possible, one needs a family of templates with a relatively small number of members that manages to pick up any detectable signal with only a tiny reduction in signal-to-noise ratio. Evidently, one family is better than another if it accomplishes its goal with a smaller number of templates. Following the geometric language of Owen, we have studied the performance of the post 1.5 -Newtonian family of templates on detecting post 2 -Newtonian signals for binaries. Several technical issues arise from the fact that the two types of waveforms cannot be made to coincide by a suitable choice of parameters. In general, the parameter space of the signals is not identical with the parameter space of the templates, although in our case they are of the same dimension, and one has to take into account all such peculiarities before drawing any conclusion. An interesting result we have obtained is that the post 1.5 -Newtonian family of templates happens to be more economical for detecting post 2 -Newtonian signals than the perfectly accurate post 2 -Newtonian family of templates itself. The number of templates is reduced by 20-30%, depending on the acceptable level of reduction in signal-to-noise ratio due to discretization of the family of templates. This makes the post 1.5 -Newtonian family of templates more favorable

  13. 100 MH/sub z/ fiber optic single transient gamma ray detection system

    International Nuclear Information System (INIS)

    Ogle, J.W.; Smith, R.C.; Ward, M.; Ramsey, R.; Hollabaugh, J.

    1984-01-01

    A fiber optic system has been developed to measure single transient gamma rays. The gamma ray signature is converted to light by the Cerenkov process in a 20 cm length of radiation resistant optical fiber. The signal is transmitted over 1 km of optical fiber and detected by state-of-the-art, 175 MHz analog receivers. The receivers are based on silicon PIN detectors with transimpedance hybrid amplifiers and two stages of power amplification. The dc coupled receivers have less than 2% distortion up to 5 volts with less than 10 mV rms noise and a responsivity of 37,500 V/watt at 800 nm. A calibration system measures relative fiber to fiber transit time delays and system sensitivity. System bandwidth measurements utilized an electron linear accelerator (Linac) with a 50 ps electron pulse as the Cerenkov light source. The system will be described with supporting calibration and characterization data of parts of the system and the whole system. 5 references, 7 figures, 4 tables

  14. Stator fault detection for multi-phase machines with multiple reference frames transformation

    DEFF Research Database (Denmark)

    Bianchini, Claudio; Fornasiero, Emanuele; Matzen, T.N.

    2009-01-01

    The paper focuses on a new diagnostic index for fault detection of a five-phase permanent-magnet machine. This machine has been designed for fault tolerant applications, and it is characterized by a mutual inductance equal to zero and a high self inductance, in order to limit the short-circuit cu...

  15. Extraction-less, rapid assay for the direct detection of 2,4,6-trichloroanisole (TCA) in cork samples.

    Science.gov (United States)

    Apostolou, Theofylaktos; Pascual, Nuria; Marco, M-Pilar; Moschos, Anastassios; Petropoulos, Anastassios; Kaltsas, Grigoris; Kintzios, Spyridon

    2014-07-01

    2,4,6-trichloroanisole (TCA), the cork taint molecule, has been the target of several analytical approaches over the few past years. In spite of the development of highly efficient and sensitive tools for its detection, ranging from advanced chromatography to biosensor-based techniques, a practical breakthrough for routine cork screening purposes has not yet been realized, in part due to the requirement of a lengthy extraction of TCA in organic solvents, mostly 12% ethanol and the high detectability required. In the present report, we present a modification of a previously reported biosensor system based on the measurement of the electric response of cultured fibroblast cells membrane-engineered with the pAb78 TCA-specific antibody. Samples were prepared by macerating cork tissue and mixing it directly with the cellular biorecognition elements, without any intervening extraction process. By using this novel approach, we were able to detect TCA in just five minutes at extremely low concentrations (down to 0.2 ppt). The novel biosensor offers a number of practical benefits, including a very considerable reduction in the total assay time by one day, and a full portability, enabling its direct employment for on-site, high throughput screening of cork in the field and production facilities, without requiring any type of supporting infrastructure. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Multidrug-resistant tuberculosis treatment failure detection depends on monitoring interval and microbiological method

    Science.gov (United States)

    White, Richard A.; Lu, Chunling; Rodriguez, Carly A.; Bayona, Jaime; Becerra, Mercedes C.; Burgos, Marcos; Centis, Rosella; Cohen, Theodore; Cox, Helen; D'Ambrosio, Lia; Danilovitz, Manfred; Falzon, Dennis; Gelmanova, Irina Y.; Gler, Maria T.; Grinsdale, Jennifer A.; Holtz, Timothy H.; Keshavjee, Salmaan; Leimane, Vaira; Menzies, Dick; Milstein, Meredith B.; Mishustin, Sergey P.; Pagano, Marcello; Quelapio, Maria I.; Shean, Karen; Shin, Sonya S.; Tolman, Arielle W.; van der Walt, Martha L.; Van Deun, Armand; Viiklepp, Piret

    2016-01-01

    Debate persists about monitoring method (culture or smear) and interval (monthly or less frequently) during treatment for multidrug-resistant tuberculosis (MDR-TB). We analysed existing data and estimated the effect of monitoring strategies on timing of failure detection. We identified studies reporting microbiological response to MDR-TB treatment and solicited individual patient data from authors. Frailty survival models were used to estimate pooled relative risk of failure detection in the last 12 months of treatment; hazard of failure using monthly culture was the reference. Data were obtained for 5410 patients across 12 observational studies. During the last 12 months of treatment, failure detection occurred in a median of 3 months by monthly culture; failure detection was delayed by 2, 7, and 9 months relying on bimonthly culture, monthly smear and bimonthly smear, respectively. Risk (95% CI) of failure detection delay resulting from monthly smear relative to culture is 0.38 (0.34–0.42) for all patients and 0.33 (0.25–0.42) for HIV-co-infected patients. Failure detection is delayed by reducing the sensitivity and frequency of the monitoring method. Monthly monitoring of sputum cultures from patients receiving MDR-TB treatment is recommended. Expanded laboratory capacity is needed for high-quality culture, and for smear microscopy and rapid molecular tests. PMID:27587552

  17. When More Is Less

    DEFF Research Database (Denmark)

    Klein, Kevin; Scholl, Joep H G; De Bruin, Marie L

    2018-01-01

    Concerns have been expressed that large numbers of nonvalue-added reports have been accumulating in adverse drug reaction (ADR) databases, for example, via patient support programs. We performed an assessment of the impact of such reports, which we refer to as "precautionary reports," on safety s...

  18. Automated real-time detection of tonic-clonic seizures using a wearable EMG device

    DEFF Research Database (Denmark)

    Beniczky, Sándor; Conradsen, Isa; Henning, Oliver

    2018-01-01

    OBJECTIVE: To determine the accuracy of automated detection of generalized tonic-clonic seizures (GTCS) using a wearable surface EMG device. METHODS: We prospectively tested the technical performance and diagnostic accuracy of real-time seizure detection using a wearable surface EMG device....... The seizure detection algorithm and the cutoff values were prespecified. A total of 71 patients, referred to long-term video-EEG monitoring, on suspicion of GTCS, were recruited in 3 centers. Seizure detection was real-time and fully automated. The reference standard was the evaluation of video-EEG recordings...

  19. [Advance on study development of detection of ciguatoxins].

    Science.gov (United States)

    Yuan, Jianhui; Zhao, Kunshan; Zhuang, Zhixiong

    2007-11-01

    Ciguatoxin may be a terrible coral fish toxin that can result in poisoning in people who eat fish containing ciguatoxin. Being lack of a convenient and accurate detection method for ciguatoxin, Ciguatera fish poisoning have occurred from time to time. To provide references for detection and prevention of ciguatera fish poisoning, in this paper, the current detection methods of ciguatoxin were reviewed.

  20. Development of a RIA for clonidine and its comparison with the reference methods

    International Nuclear Information System (INIS)

    Arndts, D.; Staehle, H.; Foerster, H.J.

    1981-01-01

    A radioimmunoassay for clonidine was optimized by introducing, as a tracer ligand, an iodinized clonidine derivative specifically labeled with more than 500 Ci/mMol. The detection limit of clonidine was 10 pg/ml. The high assay specificity was demonstrated by a double isotope technique. The intraassay coefficient of variance (VK) was less than 4% for any concentration, the interassay VK did not exceed 8.3%. The assay reliability was increased when the plasma samples were diluted 1:5, prior to analysis, in normal human blood plasma, which was also used for the preparation of the calibration samples. In a comparative manner, this assay system was subjected to double-blind accuracy control tests, including all other reference methods so far described for clonidine analysis in blood plasma samples. The RIA technique presented here turned out to be the most sensitive and most reliable method, requiring, moreover, the smallest volumes of blood plasma (0.05 ml). This procedure was appropriate for routine tests, since one technician could perform 500 sample analyses a day. The advantages and disadvantages of each method are discussed

  1. A set of 14 DIP-SNP markers to detect unbalanced DNA mixtures.

    Science.gov (United States)

    Liu, Zhizhen; Liu, Jinding; Wang, Jiaqi; Chen, Deqing; Liu, Zidong; Shi, Jie; Li, Zeqin; Li, Wenyan; Zhang, Gengqian; Du, Bing

    2018-03-04

    Unbalanced DNA mixture is still a difficult problem for forensic practice. DIP-STRs are useful markers for detection of minor DNA but they are not widespread in the human genome and having long amplicons. In this study, we proposed a novel type of genetic marker, termed DIP-SNP. DIP-SNP refers to the combination of INDEL and SNP in less than 300bp length of human genome. The multiplex PCR and SNaPshot assay were established for 14 DIP-SNP markers in a Chinese Han population from Shanxi, China. This novel compound marker allows detection of the minor DNA contributor with sensitivity from 1:50 to 1:1000 in a DNA mixture of any gender with 1 ng-10 ng DNA template. Most of the DIP-SNP markers had a relatively high probability of informative alleles with an average I value of 0.33. In all, we proposed DIP-SNP as a novel kind of genetic marker for detection of minor contributor from unbalanced DNA mixture and established the detection method by associating the multiplex PCR and SNaPshot assay. DIP-SNP polymorphisms are promising markers for forensic or clinical mixture examination because they are shorter, widespread and higher sensitive. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. GMDD: a database of GMO detection methods.

    Science.gov (United States)

    Dong, Wei; Yang, Litao; Shen, Kailin; Kim, Banghyun; Kleter, Gijs A; Marvin, Hans J P; Guo, Rong; Liang, Wanqi; Zhang, Dabing

    2008-06-04

    Since more than one hundred events of genetically modified organisms (GMOs) have been developed and approved for commercialization in global area, the GMO analysis methods are essential for the enforcement of GMO labelling regulations. Protein and nucleic acid-based detection techniques have been developed and utilized for GMOs identification and quantification. However, the information for harmonization and standardization of GMO analysis methods at global level is needed. GMO Detection method Database (GMDD) has collected almost all the previous developed and reported GMOs detection methods, which have been grouped by different strategies (screen-, gene-, construct-, and event-specific), and also provide a user-friendly search service of the detection methods by GMO event name, exogenous gene, or protein information, etc. In this database, users can obtain the sequences of exogenous integration, which will facilitate PCR primers and probes design. Also the information on endogenous genes, certified reference materials, reference molecules, and the validation status of developed methods is included in this database. Furthermore, registered users can also submit new detection methods and sequences to this database, and the newly submitted information will be released soon after being checked. GMDD contains comprehensive information of GMO detection methods. The database will make the GMOs analysis much easier.

  3. A Standardized Reference Data Set for Vertebrate Taxon Name Resolution.

    Science.gov (United States)

    Zermoglio, Paula F; Guralnick, Robert P; Wieczorek, John R

    2016-01-01

    Taxonomic names associated with digitized biocollections labels have flooded into repositories such as GBIF, iDigBio and VertNet. The names on these labels are often misspelled, out of date, or present other problems, as they were often captured only once during accessioning of specimens, or have a history of label changes without clear provenance. Before records are reliably usable in research, it is critical that these issues be addressed. However, still missing is an assessment of the scope of the problem, the effort needed to solve it, and a way to improve effectiveness of tools developed to aid the process. We present a carefully human-vetted analysis of 1000 verbatim scientific names taken at random from those published via the data aggregator VertNet, providing the first rigorously reviewed, reference validation data set. In addition to characterizing formatting problems, human vetting focused on detecting misspelling, synonymy, and the incorrect use of Darwin Core. Our results reveal a sobering view of the challenge ahead, as less than 47% of name strings were found to be currently valid. More optimistically, nearly 97% of name combinations could be resolved to a currently valid name, suggesting that computer-aided approaches may provide feasible means to improve digitized content. Finally, we associated names back to biocollections records and fit logistic models to test potential drivers of issues. A set of candidate variables (geographic region, year collected, higher-level clade, and the institutional digitally accessible data volume) and their 2-way interactions all predict the probability of records having taxon name issues, based on model selection approaches. We strongly encourage further experiments to use this reference data set as a means to compare automated or computer-aided taxon name tools for their ability to resolve and improve the existing wealth of legacy data.

  4. A Standardized Reference Data Set for Vertebrate Taxon Name Resolution.

    Directory of Open Access Journals (Sweden)

    Paula F Zermoglio

    Full Text Available Taxonomic names associated with digitized biocollections labels have flooded into repositories such as GBIF, iDigBio and VertNet. The names on these labels are often misspelled, out of date, or present other problems, as they were often captured only once during accessioning of specimens, or have a history of label changes without clear provenance. Before records are reliably usable in research, it is critical that these issues be addressed. However, still missing is an assessment of the scope of the problem, the effort needed to solve it, and a way to improve effectiveness of tools developed to aid the process. We present a carefully human-vetted analysis of 1000 verbatim scientific names taken at random from those published via the data aggregator VertNet, providing the first rigorously reviewed, reference validation data set. In addition to characterizing formatting problems, human vetting focused on detecting misspelling, synonymy, and the incorrect use of Darwin Core. Our results reveal a sobering view of the challenge ahead, as less than 47% of name strings were found to be currently valid. More optimistically, nearly 97% of name combinations could be resolved to a currently valid name, suggesting that computer-aided approaches may provide feasible means to improve digitized content. Finally, we associated names back to biocollections records and fit logistic models to test potential drivers of issues. A set of candidate variables (geographic region, year collected, higher-level clade, and the institutional digitally accessible data volume and their 2-way interactions all predict the probability of records having taxon name issues, based on model selection approaches. We strongly encourage further experiments to use this reference data set as a means to compare automated or computer-aided taxon name tools for their ability to resolve and improve the existing wealth of legacy data.

  5. A Comparative Study of Different EEG Reference Choices for Diagnosing Unipolar Depression.

    Science.gov (United States)

    Mumtaz, Wajid; Malik, Aamir Saeed

    2018-06-02

    The choice of an electroencephalogram (EEG) reference has fundamental importance and could be critical during clinical decision-making because an impure EEG reference could falsify the clinical measurements and subsequent inferences. In this research, the suitability of three EEG references was compared while classifying depressed and healthy brains using a machine-learning (ML)-based validation method. In this research, the EEG data of 30 unipolar depressed subjects and 30 age-matched healthy controls were recorded. The EEG data were analyzed in three different EEG references, the link-ear reference (LE), average reference (AR), and reference electrode standardization technique (REST). The EEG-based functional connectivity (FC) was computed. Also, the graph-based measures, such as the distances between nodes, minimum spanning tree, and maximum flow between the nodes for each channel pair, were calculated. An ML scheme provided a mechanism to compare the performances of the extracted features that involved a general framework such as the feature extraction (graph-based theoretic measures), feature selection, classification, and validation. For comparison purposes, the performance metrics such as the classification accuracies, sensitivities, specificities, and F scores were computed. When comparing the three references, the diagnostic accuracy showed better performances during the REST, while the LE and AR showed less discrimination between the two groups. Based on the results, it can be concluded that the choice of appropriate reference is critical during the clinical scenario. The REST reference is recommended for future applications of EEG-based diagnosis of mental illnesses.

  6. Reference Gene Screening for Analyzing Gene Expression Across Goat Tissue

    Directory of Open Access Journals (Sweden)

    Yu Zhang

    2013-12-01

    Full Text Available Real-time quantitative PCR (qRT-PCR is one of the important methods for investigating the changes in mRNA expression levels in cells and tissues. Selection of the proper reference genes is very important when calibrating the results of real-time quantitative PCR. Studies on the selection of reference genes in goat tissues are limited, despite the economic importance of their meat and dairy products. We used real-time quantitative PCR to detect the expression levels of eight reference gene candidates (18S, TBP, HMBS, YWHAZ, ACTB, HPRT1, GAPDH and EEF1A2 in ten tissues types sourced from Boer goats. The optimal reference gene combination was selected according to the results determined by geNorm, NormFinder and Bestkeeper software packages. The analyses showed that tissue is an important variability factor in genes expression stability. When all tissues were considered, 18S, TBP and HMBS is the optimal reference combination for calibrating quantitative PCR analysis of gene expression from goat tissues. Dividing data set by tissues, ACTB was the most stable in stomach, small intestine and ovary, 18S in heart and spleen, HMBS in uterus and lung, TBP in liver, HPRT1 in kidney and GAPDH in muscle. Overall, this study provided valuable information about the goat reference genes that can be used in order to perform a proper normalisation when relative quantification by qRT-PCR studies is undertaken.

  7. A new approach to motion control of torque-constrained manipulators by using time-scaling of reference trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Moreno-Valenzuela, Javier; Orozco-Manriquez, Ernesto [Digital del IPN, CITEDI-IPN, Tijuana, (Mexico)

    2009-12-15

    We introduce a control scheme based on using a trajectory tracking controller and an algorithm for on-line time scaling of the reference trajectories. The reference trajectories are time-scaled according to the measured tracking errors and the detected torque/acceleration saturation. Experiments are presented to illustrate the advantages of the proposed approach

  8. A new approach to motion control of torque-constrained manipulators by using time-scaling of reference trajectories

    International Nuclear Information System (INIS)

    Moreno-Valenzuela, Javier; Orozco-Manriquez, Ernesto

    2009-01-01

    We introduce a control scheme based on using a trajectory tracking controller and an algorithm for on-line time scaling of the reference trajectories. The reference trajectories are time-scaled according to the measured tracking errors and the detected torque/acceleration saturation. Experiments are presented to illustrate the advantages of the proposed approach

  9. Spectral methods for the detection of network community structure: a comparative analysis

    International Nuclear Information System (INIS)

    Shen, Hua-Wei; Cheng, Xue-Qi

    2010-01-01

    Spectral analysis has been successfully applied to the detection of community structure of networks, respectively being based on the adjacency matrix, the standard Laplacian matrix, the normalized Laplacian matrix, the modularity matrix, the correlation matrix and several other variants of these matrices. However, the comparison between these spectral methods is less reported. More importantly, it is still unclear which matrix is more appropriate for the detection of community structure. This paper answers the question by evaluating the effectiveness of these five matrices against benchmark networks with heterogeneous distributions of node degree and community size. Test results demonstrate that the normalized Laplacian matrix and the correlation matrix significantly outperform the other three matrices at identifying the community structure of networks. This indicates that it is crucial to take into account the heterogeneous distribution of node degree when using spectral analysis for the detection of community structure. In addition, to our surprise, the modularity matrix exhibits very similar performance to the adjacency matrix, which indicates that the modularity matrix does not gain benefits from using the configuration model as a reference network with the consideration of the node degree heterogeneity

  10. Optimal Reference Genes for Gene Expression Normalization in Trichomonas vaginalis

    Science.gov (United States)

    dos Santos, Odelta; de Vargas Rigo, Graziela; Frasson, Amanda Piccoli; Macedo, Alexandre José; Tasca, Tiana

    2015-01-01

    Trichomonas vaginalis is the etiologic agent of trichomonosis, the most common non-viral sexually transmitted disease worldwide. This infection is associated with several health consequences, including cervical and prostate cancers and HIV acquisition. Gene expression analysis has been facilitated because of available genome sequences and large-scale transcriptomes in T. vaginalis, particularly using quantitative real-time polymerase chain reaction (qRT-PCR), one of the most used methods for molecular studies. Reference genes for normalization are crucial to ensure the accuracy of this method. However, to the best of our knowledge, a systematic validation of reference genes has not been performed for T. vaginalis. In this study, the transcripts of nine candidate reference genes were quantified using qRT-PCR under different cultivation conditions, and the stability of these genes was compared using the geNorm and NormFinder algorithms. The most stable reference genes were α-tubulin, actin and DNATopII, and, conversely, the widely used T. vaginalis reference genes GAPDH and β-tubulin were less stable. The PFOR gene was used to validate the reliability of the use of these candidate reference genes. As expected, the PFOR gene was upregulated when the trophozoites were cultivated with ferrous ammonium sulfate when the DNATopII, α-tubulin and actin genes were used as normalizing gene. By contrast, the PFOR gene was downregulated when the GAPDH gene was used as an internal control, leading to misinterpretation of the data. These results provide an important starting point for reference gene selection and gene expression analysis with qRT-PCR studies of T. vaginalis. PMID:26393928

  11. Thick-film voltammetric pH-sensors with internal indicator and reference species

    DEFF Research Database (Denmark)

    Musa, Arnaud Emmanuel; Alonso-Lomillo, María Asunción; del Campo, Francisco Javier

    2012-01-01

    , low cost and ease of fabrication. More importantly, as opposed to conventional voltammetric systems where the height of the voltammetric peaks is taken into account to quantify the amount of a species of interest, here, the difference between the peak potential of the indicator species and the peak...... potential of the reference species is used. Thus, this measurement principle makes the electrochemical system presented here less dependent on the potential of the reference electrode (RE), as is often the case in other electrochemical systems. The developed system displays very promising performances...

  12. An Impedance-Based Mold Sensor with on-Chip Optical Reference

    Directory of Open Access Journals (Sweden)

    Poornachandra Papireddy Vinayaka

    2016-09-01

    Full Text Available A new miniaturized sensor system with an internal optical reference for the detection of mold growth is presented. The sensor chip comprises a reaction chamber provided with a culture medium that promotes the growth of mold species from mold spores. The mold detection is performed by measuring impedance changes with integrated electrodes fabricated inside the reaction chamber. The impedance change in the culture medium is caused by shifts in the pH (i.e., from 5.5 to 8 as the mold grows. In order to determine the absolute pH value without the need for calibration, a methyl red indicator dye has been added to the culture medium. It changes the color of the medium as the pH passes specific values. This colorimetric principle now acts as a reference measurement. It also allows the sensitivity of the impedance sensor to be established in terms of impedance change per pH unit. Major mold species that are involved in the contamination of food, paper and indoor environments, like Fusarium oxysporum, Fusarium incarnatum, Eurotium amstelodami, Aspergillus penicillioides and Aspergillus restrictus, have been successfully analyzed on-chip.

  13. A one-step, real-time PCR assay for rapid detection of rhinovirus.

    Science.gov (United States)

    Do, Duc H; Laus, Stella; Leber, Amy; Marcon, Mario J; Jordan, Jeanne A; Martin, Judith M; Wadowsky, Robert M

    2010-01-01

    One-step, real-time PCR assays for rhinovirus have been developed for a limited number of PCR amplification platforms and chemistries, and some exhibit cross-reactivity with genetically similar enteroviruses. We developed a one-step, real-time PCR assay for rhinovirus by using a sequence detection system (Applied Biosystems; Foster City, CA). The primers were designed to amplify a 120-base target in the noncoding region of picornavirus RNA, and a TaqMan (Applied Biosystems) degenerate probe was designed for the specific detection of rhinovirus amplicons. The PCR assay had no cross-reactivity with a panel of 76 nontarget nucleic acids, which included RNAs from 43 enterovirus strains. Excellent lower limits of detection relative to viral culture were observed for the PCR assay by using 38 of 40 rhinovirus reference strains representing different serotypes, which could reproducibly detect rhinovirus serotype 2 in viral transport medium containing 10 to 10,000 TCID(50) (50% tissue culture infectious dose endpoint) units/ml of the virus. However, for rhinovirus serotypes 59 and 69, the PCR assay was less sensitive than culture. Testing of 48 clinical specimens from children with cold-like illnesses for rhinovirus by the PCR and culture assays yielded detection rates of 16.7% and 6.3%, respectively. For a batch of 10 specimens, the entire assay was completed in 4.5 hours. This real-time PCR assay enables detection of many rhinovirus serotypes with the Applied Biosystems reagent-instrument platform.

  14. A 5 V-to-3.3 V CMOS Linear Regulator with Three-Output Temperature-Independent Reference Voltages

    Directory of Open Access Journals (Sweden)

    San-Fu Wang

    2016-01-01

    Full Text Available This paper presents a 5 V-to-3.3 V linear regulator circuit, which uses 3.3 V CMOS transistors to replace the 5 V CMOS transistors. Thus, the complexity of the manufacturing semiconductor process can be improved. The proposed linear regulator is implemented by cascode architecture, which requires three different reference voltages as the bias voltages of its circuit. Thus, the three-output temperature-independent reference voltage circuit is proposed, which provides three accurate reference voltages simultaneously. The three-output temperature-independent reference voltages also can be used in other circuits of the chip. By using the proposed temperature-independent reference voltages, the proposed linear regulator can provide an accurate output voltage, and it is suitable for low cost, small size, and highly integrated system-on-chip (SoC applications. Moreover, the proposed linear regulator uses the cascode technique, which improves both the gain performance and the isolation performance. Therefore, the proposed linear regulator has a good performance in reference voltage to output voltage isolation. The voltage variation of the linear regulator is less than 2.153% in the temperature range of −40°C–120°C, and the power supply rejection ratio (PSRR is less than −42.8 dB at 60 Hz. The regulator can support 0~200 mA output current. The core area is less than 0.16 mm2.

  15. Analysis of SMELS and reference materials for validation of the k0-based internal monostandard NAA method using in-situ detection efficiency

    Science.gov (United States)

    Acharya, R.; Swain, K. K.; Reddy, A. V. R.

    2010-10-01

    Three synthetic multielement standards (SMELS I, II and III) and two reference materials (RMs), SL-3 and Soil-7 of IAEA were analyzed for validation of the k0-based internal monostandard neutron activation analysis (IM-NAA) method utilizing in-situ relative detection efficiency. The internal monostandards used in SMELS and RMs were Au and Sc, respectively. The samples were irradiated in Apsara and Dhruva reactors, BARC and radioactive assay was carried out using a 40% relative efficiency HPGe detector coupled to an 8 k MCA. Concentrations of 23 elements were determined in both SMELS and RMs. In the case of RMs, concentrations of a few elements, whose certified values are not available, could also be determined. The % deviations for the elements determined in SMELS with respect to the assigned values and RMs with respect to certified values were within ±8%. The Z-score values at 95% confidence level for most of the elements in both the materials were within ±1.

  16. Dual-energy CT for detection of traumatic bone bruises in the knee joint

    International Nuclear Information System (INIS)

    Seo, Sang Hyun; Sohn, Young Jun; Lee, Chong Ho; Park, Seong Hoon; Kim, Hye Won; Juhng, Seon Kwan

    2013-01-01

    To evaluate the diagnostic performance of dual-energy computed tomography (DECT) in detecting traumatic bone marrow lesions in patients with acute knee injury. Between August 2011 and June 2012, 22 patients presenting with an acute knee injury, including 4 patients who were referred for bilateral knee trauma, underwent DECT (80 kVp and 140 kVp) and MR imaging. DECT data were postprocessed using a three-dimensional, color-coded, virtual non-calcium technique (VNC). DECT data were graded by 2 blinded independent readers using a four-point system (1 = distinct bone marrow lesion, 2 = less distinct bone marrow lesion, 3 = equivocal, 4 = none) for 6 femoral and tibial regions and 2 patellar regions. Routine MR knee imaging served as the reference standard. MR images showed bone bruises in 81 of 364 regions. The overall sensitivity, specificity, positive predictive value, and negative predictive value of DECT for bone bruises were 65.4%, 98.2%, 91.4%, and 90.8%, respectively, for Reader 1 and 70.3%, 93.6%, 76.0%, and 91.7%, respectively, for Reader 2. In particular, tibial bone bruises could be found more easily with better sensitivity (80.2%). The color-coded VNC technique with reconstructions from the DECT maybe helpful in detecting traumatic bone bruises with moderate sensitivity and excellent specificity compared to MR imaging.

  17. Dual-energy CT for detection of traumatic bone bruises in the knee joint

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Sang Hyun; Sohn, Young Jun; Lee, Chong Ho; Park, Seong Hoon; Kim, Hye Won; Juhng, Seon Kwan [Dept. of Radiology, Wonkwang University Hospital, Iksan (Korea, Republic of)

    2013-12-15

    To evaluate the diagnostic performance of dual-energy computed tomography (DECT) in detecting traumatic bone marrow lesions in patients with acute knee injury. Between August 2011 and June 2012, 22 patients presenting with an acute knee injury, including 4 patients who were referred for bilateral knee trauma, underwent DECT (80 kVp and 140 kVp) and MR imaging. DECT data were postprocessed using a three-dimensional, color-coded, virtual non-calcium technique (VNC). DECT data were graded by 2 blinded independent readers using a four-point system (1 = distinct bone marrow lesion, 2 = less distinct bone marrow lesion, 3 = equivocal, 4 = none) for 6 femoral and tibial regions and 2 patellar regions. Routine MR knee imaging served as the reference standard. MR images showed bone bruises in 81 of 364 regions. The overall sensitivity, specificity, positive predictive value, and negative predictive value of DECT for bone bruises were 65.4%, 98.2%, 91.4%, and 90.8%, respectively, for Reader 1 and 70.3%, 93.6%, 76.0%, and 91.7%, respectively, for Reader 2. In particular, tibial bone bruises could be found more easily with better sensitivity (80.2%). The color-coded VNC technique with reconstructions from the DECT maybe helpful in detecting traumatic bone bruises with moderate sensitivity and excellent specificity compared to MR imaging.

  18. Enterprise Reference Library

    Science.gov (United States)

    Bickham, Grandin; Saile, Lynn; Havelka, Jacque; Fitts, Mary

    2011-01-01

    Introduction: Johnson Space Center (JSC) offers two extensive libraries that contain journals, research literature and electronic resources. Searching capabilities are available to those individuals residing onsite or through a librarian s search. Many individuals have rich collections of references, but no mechanisms to share reference libraries across researchers, projects, or directorates exist. Likewise, information regarding which references are provided to which individuals is not available, resulting in duplicate requests, redundant labor costs and associated copying fees. In addition, this tends to limit collaboration between colleagues and promotes the establishment of individual, unshared silos of information The Integrated Medical Model (IMM) team has utilized a centralized reference management tool during the development, test, and operational phases of this project. The Enterprise Reference Library project expands the capabilities developed for IMM to address the above issues and enhance collaboration across JSC. Method: After significant market analysis for a multi-user reference management tool, no available commercial tool was found to meet this need, so a software program was built around a commercial tool, Reference Manager 12 by The Thomson Corporation. A use case approach guided the requirements development phase. The premise of the design is that individuals use their own reference management software and export to SharePoint when their library is incorporated into the Enterprise Reference Library. This results in a searchable user-specific library application. An accompanying share folder will warehouse the electronic full-text articles, which allows the global user community to access full -text articles. Discussion: An enterprise reference library solution can provide a multidisciplinary collection of full text articles. This approach improves efficiency in obtaining and storing reference material while greatly reducing labor, purchasing and

  19. Methodologic quality and relevance of references in pharmaceutical advertisements in a Canadian medical journal.

    Science.gov (United States)

    Lexchin, J; Holbrook, A

    1994-07-01

    To evaluate the methodologic quality and relevance of references in pharmaceutical advertisements in the Canadian Medical Association Journal (CMAJ). Analytic study. All 114 references cited in the first 22 distinct pharmaceutical advertisements in volume 146 of CMAJ. Mean methodologic quality score (modified from the 6-point scale used to assess articles in the American College of Physicians' Journal Club) and mean relevance score (based on a new 5-point scale) for all references in each advertisement. Twenty of the 22 companies responded, sending 78 (90%) of the 87 references requested. The mean methodologic quality score was 58% (95% confidence limits [CL] 51% and 65%) and the mean relevance score 76% (95% CL 72% and 80%). The two mean scores were statistically lower than the acceptable score of 80% (p e., other than reports of clinical trials). Half of the advertisements had a methodologic quality score of less than 65%, but only five had a relevance score of less than 65%. Although the relevance of most of the references was within minimal acceptable limits, the methodologic quality was often unacceptable. Because advertisements are an important part of pharmaceutical marketing and education, we suggest that companies develop written standards for their advertisements and monitor their advertisements for adherence to these standards. We also suggest that the Pharmaceutical Advertising Advisory Board develop more stringent guidelines for advertising and that it enforce these guidelines in a consistent, rigorous fashion.

  20. Detection of sexual orientation ("gaydar") by homosexual and heterosexual women.

    Science.gov (United States)

    Lyons, Minna; Lynch, Aoife; Brewer, Gayle; Bruno, Davide

    2014-02-01

    Although there has been considerable research investigating the ability to identify sexual orientation from static images, or "gaydar," few studies have considered the role of female sexual orientation or sexual interest (for example, sociosexual orientation) in judgment accuracy. In two studies, we investigated the sexuality detection ability, and masculinity and femininity as cues used in judgment. In Study 1, we recruited heterosexual (N = 55) and homosexual (N = 71) women to rate the sexual orientation of homosexual and heterosexual male and female targets (N = 80: 20 heterosexual men, 20 homosexual men, 20 heterosexual women, and 20 homosexual women). We found that detection accuracy was better than chance levels for both male and female targets and that male targets were more likely to be falsely labeled as homosexual than female targets were. Overall, female faces were more accurately identified as heterosexual or homosexual than male faces and homosexual female raters were biased towards labeling targets as homosexual. Sociosexuality did not influence the accuracy with which targets were identified as heterosexual or homosexual. In Study 2, 100 heterosexual and 20 homosexual women rated the stimulus for masculinity and femininity. Heterosexual women were rated as more feminine and less masculine than homosexual women and homosexual men were rated as more feminine and less masculine than heterosexual men. Sexual orientation of the judges did not affect the ratings. The results were discussed with a reference to evolutionary and cultural influences affecting sexual orientation judgment accuracy.

  1. 2002 reference document; Document de reference 2002

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    This 2002 reference document of the group Areva, provides information on the society. Organized in seven chapters, it presents the persons responsible for the reference document and for auditing the financial statements, information pertaining to the transaction, general information on the company and share capital, information on company operation, changes and future prospects, assets, financial position, financial performance, information on company management and executive board and supervisory board, recent developments and future prospects. (A.L.B.)

  2. Statistical methods for damage detection applied to civil structures

    DEFF Research Database (Denmark)

    Gres, Szymon; Ulriksen, Martin Dalgaard; Döhler, Michael

    2017-01-01

    Damage detection consists of monitoring the deviations of a current system from its reference state, characterized by some nominal property repeatable for every healthy state. Preferably, the damage detection is performed directly on vibration data, hereby avoiding modal identification of the str...

  3. Current status of natural orifice trans-endoscopic surgery (NOTES and laparoendoscopic single site surgery (LESS in urologic surgery

    Directory of Open Access Journals (Sweden)

    Rafael E. Sanchez-Salas

    2010-08-01

    Full Text Available Laparoendoscopic single site surgery (LESS and natural orifice transluminal endoscopic surgery (NOTES represent novel approaches in urological surgery. To perform a review of the literature in order describe the current status of LESS and NOTES in Urology. References for this manuscript were obtained by performing a review of the available literature in PubMed from 01-01-02 to 15-05-09. Search terms included single port, single site, NOTES, LESS and single incision. A total of 412 manuscripts were initially identified. Out of these, 64 manuscripts were selected based in their urological content. The manuscript features subheadings for experimental and clinical studies, as NOTES-LESS is a new surgical technique and its future evolution will probably rely in initial verified feasibility. A subheading for reviews presents information regarding common language and consensus for the techniques. The issue of complications published in clinical series and the future needs of NOTES-LESS, are also presented.

  4. Feasibility of touch-less control of operating room lights.

    Science.gov (United States)

    Hartmann, Florian; Schlaefer, Alexander

    2013-03-01

    Today's highly technical operating rooms lead to fairly complex surgical workflows where the surgeon has to interact with a number of devices, including the operating room light. Hence, ideally, the surgeon could direct the light without major disruption of his work. We studied whether a gesture tracking-based control of an automated operating room light is feasible. So far, there has been little research on control approaches for operating lights. We have implemented an exemplary setup to mimic an automated light controlled by a gesture tracking system. The setup includes a articulated arm to position the light source and an off-the-shelf RGBD camera to detect the user interaction. We assessed the tracking performance using a robot-mounted hand phantom and ran a number of tests with 18 volunteers to evaluate the potential of touch-less light control. All test persons were comfortable with using the gesture-based system and quickly learned how to move a light spot on flat surface. The hand tracking error is direction-dependent and in the range of several centimeters, with a standard deviation of less than 1 mm and up to 3.5 mm orthogonal and parallel to the finger orientation, respectively. However, the subjects had no problems following even more complex paths with a width of less than 10 cm. The average speed was 0.15 m/s, and even initially slow subjects improved over time. Gestures to initiate control can be performed in approximately 2 s. Two-thirds of the subjects considered gesture control to be simple, and a majority considered it to be rather efficient. Implementation of an automated operating room light and touch-less control using an RGBD camera for gesture tracking is feasible. The remaining tracking error does not affect smooth control, and the use of the system is intuitive even for inexperienced users.

  5. Conversion of ICRP male reference phantom to polygon-surface phantom

    Science.gov (United States)

    Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi

    2013-10-01

    The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (original ICRP reference phantoms, it is believed that the polygon-surface version of ICRP reference phantoms properly developed will not only provide the same or similar dose values (say, difference <5 or 10%) for highly penetrating radiations, but also provide correct dose values for the weakly penetrating

  6. Choosing representative body sizes for reference adults and children

    International Nuclear Information System (INIS)

    Cristy, M.

    1992-01-01

    In 1975 the International Commission on Radiological Protection published a report on Reference Man (ICRP Publication 23), and a task group of the ICRP is now revising that report. Currently 'Reference Man [adult male] is defined as being between 20-30 years of age, weighing 70 kg, is 170 cm in height, is a Caucasian and is a Western European or North American in habitat and custom' (ICRP 23, p. 4). A reference adult female (58 kg, 160 cm) was also defined and data on the fetus and children were given, but with less detail and fewer specific reference values because the focus of the ICRP at that time was on young male radiation workers. The 70-kg Reference Man (earlier called Standard Man) has been used in radiation protection for 40 years, including the dosimetric schema for nuclear medicine, and this 70-kg reference has been used since at least the 1920's in physiological models. As is well known, humans in most parts of the world have increased in size (height and weight) since this standard was first adopted. Taking modern European populations as a reference and expanding the age range to 20-50 years, the author now suggests 176 cm height and 73-75 kg weight for adult males and 163 cm and about 60 kg for adult females would be more appropriate. The change in height is particularly important because many anatomical and physiological parameters - e.g., lean body mass, skeletal weight, total body water, blood volume, respiratory volumes - are correlated more closely with height than with weight. The difference in lean body mass between Asian and Caucasian persons, for example, is largely or wholly due to the difference in body height. Many equations for mean body water and other whole-body measures use body height as the only or the most important parameter, and so it is important that reference body height be chosen well

  7. Comparison between digital PCR and real-time PCR in detection of Salmonella typhimurium in milk.

    Science.gov (United States)

    Wang, Meng; Yang, Junjie; Gai, Zhongtao; Huo, Shengnan; Zhu, Jianhua; Li, Jun; Wang, Ranran; Xing, Sheng; Shi, Guosheng; Shi, Feng; Zhang, Lei

    2018-02-02

    As a kind of zero-tolerance foodborne pathogens, Salmonella typhimurium poses a great threat to quality of food products and public health. Hence, rapid and efficient approaches to identify Salmonella typhimurium are urgently needed. Combined with PCR and fluorescence technique, real-time PCR (qPCR) and digital PCR (ddPCR) are regarded as suitable tools for detecting foodborne pathogens. To compare the effect between qPCR and ddPCR in detecting Salmonella typhimurium, a series of nucleic acid, pure strain culture and spiking milk samples were applied and the resistance to inhibitors referred in this article as well. Compared with qPCR, ddPCR exhibited more sensitive (10 -4 ng/μl or 10 2 cfu/ml) and less pre-culturing time (saving 2h). Moreover, ddPCR had stronger resistance to inhibitors than qPCR, yet absolute quantification hardly performed when target's concentration over 1ng/μl or 10 6 cfu/ml. This study provides an alternative strategy in detecting foodborne Salmonella typhimurium. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Linear discriminant analysis for welding fault detection

    International Nuclear Information System (INIS)

    Li, X.; Simpson, S.W.

    2010-01-01

    This work presents a new method for real time welding fault detection in industry based on Linear Discriminant Analysis (LDA). A set of parameters was calculated from one second blocks of electrical data recorded during welding and based on control data from reference welds under good conditions, as well as faulty welds. Optimised linear combinations of the parameters were determined with LDA and tested with independent data. Short arc welds in overlap joints were studied with various power sources, shielding gases, wire diameters, and process geometries. Out-of-position faults were investigated. Application of LDA fault detection to a broad range of welding procedures was investigated using a similarity measure based on Principal Component Analysis. The measure determines which reference data are most similar to a given industrial procedure and the appropriate LDA weights are then employed. Overall, results show that Linear Discriminant Analysis gives an effective and consistent performance in real-time welding fault detection.

  9. Iodine frequency references for space

    International Nuclear Information System (INIS)

    Schuldt, Thilo; Braxmaier, Claus; Döringshoff, Klaus; Peters, Achim; Oswald, Markus; Johann, Ulrich

    2017-01-01

    Optical frequency references are a key element for the realization of future space missions. They are needed for missions related to tests of fundamental physics, gravitational wave detection, Earth observation and navigation and ranging. In missions such as GRACE follow-on or LISA the optical frequency reference is used as light source for high-sensitivity inter-satellite distance metrology. While cavity-based systems are current baseline e.g. for LISA, frequency stabilization on a hyperfine transition in molecular iodine near 532 nm is a promising alternative. Due to its absolute frequency, iodine standards crucially simplify the initial spacecraft acquisition procedures. Current setups fulfill the GRACE-FO and LISA frequency stability requirements and are realized near Engineering Model level. We present the current status of our developments on Elegant Breadboard (EBB) and Engineering Model (EM) level taking into account specific design criteria for space compatibility such as compactness (size iodine spectroscopy EM: 38 × 18 × 10 cm 3 ) and robustness. Both setups achieved similar frequency stabilities of ∼ 1 · 10 −14 at an integration time of 1 s and below 5 · 10 −15 at integration times between 10 s and 1000 s. Furthermore, we present an even more compact design currently developed for a sounding rocket mission with launch in 2017. (paper)

  10. Uranium reference materials

    International Nuclear Information System (INIS)

    Donivan, S.; Chessmore, R.

    1987-07-01

    The Technical Measurements Center has prepared uranium mill tailings reference materials for use by remedial action contractors and cognizant federal and state agencies. Four materials were prepared with varying concentrations of radionuclides, using three tailings materials and a river-bottom soil diluent. All materials were ground, dried, and blended thoroughly to ensure homogeneity. The analyses on which the recommended values for nuclides in the reference materials are based were performed, using independent methods, by the UNC Geotech (UNC) Chemistry Laboratory, Grand Junction, Colorado, and by C.W. Sill (Sill), Idaho National Engineering Laboratory, Idaho Falls, Idaho. Several statistical tests were performed on the analytical data to characterize the reference materials. Results of these tests reveal that the four reference materials are homogeneous and that no large systematic bias exists between the analytical methods used by Sill and those used by TMC. The average values for radionuclides of the two data sets, representing an unbiased estimate, were used as the recommended values for concentrations of nuclides in the reference materials. The recommended concentrations of radionuclides in the four reference materials are provided. Use of these reference materials will aid in providing uniform standardization among measurements made by remedial action contractors. 11 refs., 9 tabs

  11. Time and Space Partitioning the EagleEye Reference Misson

    Science.gov (United States)

    Bos, Victor; Mendham, Peter; Kauppinen, Panu; Holsti, Niklas; Crespo, Alfons; Masmano, Miguel; de la Puente, Juan A.; Zamorano, Juan

    2013-08-01

    We discuss experiences gained by porting a Software Validation Facility (SVF) and a satellite Central Software (CSW) to a platform with support for Time and Space Partitioning (TSP). The SVF and CSW are part of the EagleEye Reference mission of the European Space Agency (ESA). As a reference mission, EagleEye is a perfect candidate to evaluate practical aspects of developing satellite CSW for and on TSP platforms. The specific TSP platform we used consists of a simulated LEON3 CPU controlled by the XtratuM separation micro-kernel. On top of this, we run five separate partitions. Each partition runs its own real-time operating system or Ada run-time kernel, which in turn are running the application software of the CSW. We describe issues related to partitioning; inter-partition communication; scheduling; I/O; and fault-detection, isolation, and recovery (FDIR).

  12. Reference Intervals of Alpha-Fetoprotein and Carcinoembryonic Antigen in the Apparently Healthy Population.

    Science.gov (United States)

    Zhang, Gao-Ming; Guo, Xu-Xiao; Ma, Xiao-Bo; Zhang, Guo-Ming

    2016-12-12

    BACKGROUND The aim of this study was to calculate 95% reference intervals and double-sided limits of serum alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) according to the CLSI EP28-A3 guideline. MATERIAL AND METHODS Serum AFP and CEA values were measured in samples from 26 000 healthy subjects in the Shuyang area receiving general health checkups. The 95% reference intervals and upper limits were calculated by using MedCalc. RESULTS We provided continuous reference intervals from 20 years old to 90 years old for AFP and CEA. The reference intervals were: AFP, 1.31-7.89 ng/ml (males) and 1.01-7.10 ng/ml (females); CEA, 0.51-4.86 ng/ml (males) and 0.35-3.45ng/ml (females). AFP and CEA were significantly positively correlated with age in both males (r=0.196 and r=0.198) and females (r=0.121 and r=0.197). CONCLUSIONS Different races or populations and different detection systems may result in different reference intervals for AFP and CEA. Continuous reference intervals of age changes are more accurate than age groups.

  13. Self-assessment in cancer patients referred to palliative care

    DEFF Research Database (Denmark)

    Strömgren, Annette S; Goldschmidt, Dorthe; Groenvold, Mogens

    2002-01-01

    the symptomatology of participating patients and examines differences in symptomatology between patients in three palliative care functions: inpatient, outpatient, and palliative home care. RESULTS: Of 267 eligible patients who were referred to a department of palliative medicine, initial self......-based study of symptomatology in consecutive cancer patients in palliative care, achieving rather complete data from the participants. The symptomatology in these patients was very pronounced. The questionnaires were able to detect clinically important differences between places of service....

  14. Characterisation of a natural quartz crystal as a reference material for microanalytical determination of Ti, Al, Li, Fe, Mn, Ga and Ge

    Science.gov (United States)

    Audetat, Andreas; Garbe-Schonberg, Dieter; Kronz, Andreas; Pettke, Thomas; Rusk, Brian G.; Donovan, John J.; Lowers, Heather

    2015-01-01

    A natural smoky quartz crystal from Shandong province, China, was characterised by laser ablation ICP-MS, electron probe microanalysis (EPMA) and solution ICP-MS to determine the concentration of twenty-four trace and ultra trace elements. Our main focus was on Ti quantification because of the increased use of this element for titanium-in-quartz (TitaniQ) thermobarometry. Pieces of a uniform growth zone of 9 mm thickness within the quartz crystal were analysed in four different LA-ICP-MS laboratories, three EPMA laboratories and one solution-ICP-MS laboratory. The results reveal reproducible concentrations of Ti (57 ± 4 μg g-1), Al (154 ± 15 μg g-1), Li (30 ± 2 μg g-1), Fe (2.2 ± 0.3 μg g-1), Mn (0.34 ± 0.04 μg g-1), Ge (1.7 ± 0.2 μg g-1) and Ga (0.020 ± 0.002 μg g-1) and detectable, but less reproducible, concentrations of Be, B, Na, Cu, Zr, Sn and Pb. Concentrations of K, Ca, Sr, Mo, Ag, Sb, Ba and Au were below the limits of detection of all three techniques. The uncertainties on the average concentration determinations by multiple techniques and laboratories for Ti, Al, Li, Fe, Mn, Ga and Ge are low; hence, this quartz can serve as a reference material or a secondary reference material for microanalytical applications involving the quantification of trace elements in quartz.

  15. Estimating clinical chemistry reference values based on an existing data set of unselected animals.

    Science.gov (United States)

    Dimauro, Corrado; Bonelli, Piero; Nicolussi, Paola; Rassu, Salvatore P G; Cappio-Borlino, Aldo; Pulina, Giuseppe

    2008-11-01

    In an attempt to standardise the determination of biological reference values, the International Federation of Clinical Chemistry (IFCC) has published a series of recommendations on developing reference intervals. The IFCC recommends the use of an a priori sampling of at least 120 healthy individuals. However, such a high number of samples and laboratory analysis is expensive, time-consuming and not always feasible, especially in veterinary medicine. In this paper, an alternative (a posteriori) method is described and is used to determine reference intervals for biochemical parameters of farm animals using an existing laboratory data set. The method used was based on the detection and removal of outliers to obtain a large sample of animals likely to be healthy from the existing data set. This allowed the estimation of reliable reference intervals for biochemical parameters in Sarda dairy sheep. This method may also be useful for the determination of reference intervals for different species, ages and gender.

  16. Reference Assessment

    Science.gov (United States)

    Bivens-Tatum, Wayne

    2006-01-01

    This article presents interesting articles that explore several different areas of reference assessment, including practical case studies and theoretical articles that address a range of issues such as librarian behavior, patron satisfaction, virtual reference, or evaluation design. They include: (1) "Evaluating the Quality of a Chat Service"…

  17. Advances of Salivary Proteomics in Oral Squamous Cell Carcinoma (OSCC Detection: An Update

    Directory of Open Access Journals (Sweden)

    Rabia Sannam Khan

    2016-12-01

    Full Text Available Oral cancer refers to malignancies that have higher morbidity and mortality rates due to the late stage diagnosis and no early detection of a reliable diagnostic marker, while oral squamous cell carcinoma (OSCC is amongst the world’s top ten most common cancers. Diagnosis of cancer requires highly sensitive and specific diagnostic tools which can support untraceable hidden sites of OSCC, yet to be unleashed, for which plenty of biomarkers are identified; the most recommended biomarker detection medium for OSCC includes biological fluids, such as blood and saliva. Saliva holds a promising future in the search for new clinical biomarkers that are easily accessible, less complex, accurate, and cost effective as well as being a non-invasive technique to follow, by analysing the malignant cells’ molecular pathology obtained from saliva through proteomic, genomic and transcriptomic approaches. However, protein biomarkers provide an immense potential for developing novel marker-based assays for oral cancer, hence this current review offers an overall focus on the discovery of a panel of candidates as salivary protein biomarkers, as well as the proteomic tools used for their identification and their significance in early oral cancer detection.

  18. Ground Motion Prediction Equations for Western Saudi Arabia from a Reference Model

    Science.gov (United States)

    Kiuchi, R.; Mooney, W. D.; Mori, J. J.; Zahran, H. M.; Al-Raddadi, W.; Youssef, S.

    2017-12-01

    Western Saudi Arabia is surrounded by several active seismic zones such as the Red Sea and the Gulf of Aqaba where a destructive magnitude 7.3 event occurred in 1995. Over the last decade, the Saudi Geological Survey (SGS) has deployed a dense seismic network that has made it possible to monitor seismic activity more accurately. For example, the network has detected multiple seismic swarms beneath the volcanic fields in western Saudi Arabia. The most recent damaging event was a M5.7 earthquake that occurred in 2009 at Harrat Lunayyir. In terms of seismic hazard assessment, Zahran et al. (2015; 2016) presented a Probabilistic Seismic Hazard Assessment (PSHA) for western Saudi Arabia that was developed using published Ground Motion Prediction Equations (GMPEs) from areas outside of Saudi Arabia. In this study, we consider 41 earthquakes of M 3.0 - 5.4, recorded on 124 stations of the SGS network, to create a set of 442 peak ground acceleration (PGA) and peak ground velocity (PGV) records with a range of epicentral distances from 3 km to 400 km. We use the GMPE model BSSA14 (Boore et al., 2014) as a reference model to estimate our own best-fitting coefficients from a regression analysis using the events occurred in western Saudi Arabia. For epicentral distances less than 100 km, our best fitting model has different source scaling in comparison with the GMPE of BSSA14 adjusted for the California region. In addition, our model indicates that the peak amplitudes have less attenuation in western Saudi Arabia than in California.

  19. Application of Optical Flow Sensors for Dead Reckoning, Heading Reference, Obstacle Detection, and Obstacle Avoidance

    Science.gov (United States)

    2015-09-01

    motion tracking and one sensor for object detection in association with an Arduino microcontroller , we built an indoor ground robot capable of...one sensor for motion tracking and one sensor for object detection in association with an Arduino microcontroller , we built an indoor ground robot...the vehicle from the generated data delivered by the optical sensor to an Arduino microcontroller . The microcontroller controls the speed, heading

  20. Optimization of reference library used in content-based medical image retrieval scheme

    International Nuclear Information System (INIS)

    Park, Sang Cheol; Sukthankar, Rahul; Mummert, Lily; Satyanarayanan, Mahadev; Zheng Bin

    2007-01-01

    Building an optimal image reference library is a critical step in developing the interactive computer-aided detection and diagnosis (I-CAD) systems of medical images using content-based image retrieval (CBIR) schemes. In this study, the authors conducted two experiments to investigate (1) the relationship between I-CAD performance and size of reference library and (2) a new reference selection strategy to optimize the library and improve I-CAD performance. The authors assembled a reference library that includes 3153 regions of interest (ROI) depicting either malignant masses (1592) or CAD-cued false-positive regions (1561) and an independent testing data set including 200 masses and 200 false-positive regions. A CBIR scheme using a distance-weighted K-nearest neighbor algorithm is applied to retrieve references that are considered similar to the testing sample from the library. The area under receiver operating characteristic curve (A z ) is used as an index to evaluate the I-CAD performance. In the first experiment, the authors systematically increased reference library size and tested I-CAD performance. The result indicates that scheme performance improves initially from A z =0.715 to 0.874 and then plateaus when the library size reaches approximately half of its maximum capacity. In the second experiment, based on the hypothesis that a ROI should be removed if it performs poorly compared to a group of similar ROIs in a large and diverse reference library, the authors applied a new strategy to identify 'poorly effective' references. By removing 174 identified ROIs from the reference library, I-CAD performance significantly increases to A z =0.914 (p<0.01). The study demonstrates that increasing reference library size and removing poorly effective references can significantly improve I-CAD performance

  1. Reevaluation of the NOAA/CMDL carbon monoxide reference scale and comparisons with CO reference gases at NASA-Langley and the Fraunhofer Institut

    Energy Technology Data Exchange (ETDEWEB)

    Novelli, P.C.; Collins, J.E. Jr.; Myers, R.C.; Sachse, G.W.; Scheel, H.E. [Univ. of Colordo, Boulder, CO (United States)]|[Science and Technology Corporation, Hampton, VA (United States)]|[NOAA, Boulder, CO (United States)]|[NASA, Langley Research Center, Hampton, VA (United States)]|[Fraunhofer-Inst. fuer Atmospharishce Umweltforschung (Germany)

    1994-06-01

    The carbon monoxide (CO) reference scale created by the National Oceanic and Atmospheric Administration/Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) is used to quantify measurements of CO in the atmosphere, calibrate standards of other laboratories and to otherwise provide reference gases to the community measuring atmospheric CO. This reference scale was created based upon a set of primary standards prepared by gravimetric methods at CMDL and has been propagated to a set of working standards. In this paper we compare CO mixing ratios assigned to the working standards by three approaches: (1) calibration against the original gravimetric standards, (2) calibration using only working standards as the reference gas, and (3) calibration against three new gravimetric standards prepared to CMDL. The agreement between these values was typically better than 1%. The calibration histories of CMDL working standards are reviewed with respect to expected rates of CO change in the atmosphere. Using a Monte Carlo approach to simulate the effect of drifting standards on calculated mixing ratios, we conclude that the error solely associated with the maintenance of standards will limit the ability to detect small CO changes in the atmosphere. We also report results of intercalibration experiments conducted between CMDL and the Diode Laser Sensor Group (DACOM) at the NASA Langley Research Center (Hampton, Virginia), and CMDL and the Fraunhofer-Institut (Garmisch-Partenkirchen, Germany). Each laboratory calibrated several working standards for CO using their reference gases, and these results were compared to calibrations conducted by CMDL. The intercomparison of eight standards (CO concentrations between approximately 100 and approximately 165 ppb) by CMDL and NASA agreed to better than +/- 2%. (Abstract Truncated)

  2. Computer Viruses: Pathology and Detection.

    Science.gov (United States)

    Maxwell, John R.; Lamon, William E.

    1992-01-01

    Explains how computer viruses were originally created, how a computer can become infected by a virus, how viruses operate, symptoms that indicate a computer is infected, how to detect and remove viruses, and how to prevent a reinfection. A sidebar lists eight antivirus resources. (four references) (LRW)

  3. Identification of a chicken (Gallus gallus) endogenous reference gene (Actb) and its application in meat adulteration.

    Science.gov (United States)

    Xiang, Wenjin; Shang, Ying; Wang, Qin; Xu, Yuancong; Zhu, Pengyu; Huang, Kunlun; Xu, Wentao

    2017-11-01

    The genes commonly used to determine meat species are mainly mitochondrial, but the copy numbers of such genes are high, meaning they cannot be accurately quantified. In this paper, for the first time, the chromosomal gene Actb was selected as an endogenous reference gene for chicken species. It was assayed in four different chicken varieties and 16 other species using both qualitative and quantitative PCR. No amplification of the Actb gene was found in species other than chicken and no allelic variations were detected in chicken. Southern blot and digital-PCR confirmed the Actb gene was present as a single copy in the chicken genome. The quantitative detection limit was 10pg of DNA, which is equivalent to eight copies. All experiments indicated that the Actb gene is a useful endogenous reference gene for chicken, and provides a convenient and accurate approach for detection of chicken in feed and food. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Nutritional Patterns in Pregnant Women Referred to Yasuj Health Care Centers

    Directory of Open Access Journals (Sweden)

    Seyed Mohammad Amin Rezaei

    2017-12-01

    Full Text Available Background: The quality and quantity of nutrition during pregnancy is very important. This study aimed at determining the nutritional patterns in pregnant women referred to Yasuj Health Care Centers. Methods: In this cross-sectional study, 360 pregnant women in the third trimester of pregnancy referred to Yasuj Health Care Centers were enrolled. FFQ questionnaire was used to determine the nutritional patterns. Results: The mean age was 26.4±4.9 years. Totally, 67.2% of pregnant women used frying as the method of cooking. Solid oils were used for cooking in 21.7% of participants. Monthly consumption of carbonated beverages was higher than milk and 67.5% of women received more and 24.2% received less calories than needed and only 8.3% received calories equivalent to their need. Totally, 81.1%, 63.3%, 55% 48.9%, and 83.9% iron, zinc, calcium, magnesium and folate were less than recommendation by the RDA, respectively. Conclusion: The result of the present study revealed that the intakes of fruits, vegetables and some micronutrients such as iron, zinc, calcium, magnesium and folate were less than recommendations in pregnant women in Yasuj. But fat intake and the intakes of food items in miscellaneous group were more than the recommendations. Nutritional educational programs seems necessary in order to create a healthy and desirable food pattern in this group.

  5. Less Daily Computer Use is Related to Smaller Hippocampal Volumes in Cognitively Intact Elderly.

    Science.gov (United States)

    Silbert, Lisa C; Dodge, Hiroko H; Lahna, David; Promjunyakul, Nutta-On; Austin, Daniel; Mattek, Nora; Erten-Lyons, Deniz; Kaye, Jeffrey A

    2016-01-01

    Computer use is becoming a common activity in the daily life of older individuals and declines over time in those with mild cognitive impairment (MCI). The relationship between daily computer use (DCU) and imaging markers of neurodegeneration is unknown. The objective of this study was to examine the relationship between average DCU and volumetric markers of neurodegeneration on brain MRI. Cognitively intact volunteers enrolled in the Intelligent Systems for Assessing Aging Change study underwent MRI. Total in-home computer use per day was calculated using mouse movement detection and averaged over a one-month period surrounding the MRI. Spearman's rank order correlation (univariate analysis) and linear regression models (multivariate analysis) examined hippocampal, gray matter (GM), white matter hyperintensity (WMH), and ventricular cerebral spinal fluid (vCSF) volumes in relation to DCU. A voxel-based morphometry analysis identified relationships between regional GM density and DCU. Twenty-seven cognitively intact participants used their computer for 51.3 minutes per day on average. Less DCU was associated with smaller hippocampal volumes (r = 0.48, p = 0.01), but not total GM, WMH, or vCSF volumes. After adjusting for age, education, and gender, less DCU remained associated with smaller hippocampal volume (p = 0.01). Voxel-wise analysis demonstrated that less daily computer use was associated with decreased GM density in the bilateral hippocampi and temporal lobes. Less daily computer use is associated with smaller brain volume in regions that are integral to memory function and known to be involved early with Alzheimer's pathology and conversion to dementia. Continuous monitoring of daily computer use may detect signs of preclinical neurodegeneration in older individuals at risk for dementia.

  6. The less-is-more effect

    Directory of Open Access Journals (Sweden)

    Konstantinos V. Katsikopoulos

    2010-07-01

    Full Text Available In inductive inference, a strong prediction is the less-is-more effect: Less information can lead to more accuracy. For the task of inferring which one of two objects has a higher value on a numerical criterion, there exist necessary and sufficient conditions under which the effect is predicted, assuming that recognition memory is perfect. Based on a simple model of imperfect recognition memory, I derive a more general characterization of the less-is-more effect, which shows the important role of the probabilities of hits and false alarms for predicting the effect. From this characterization, it follows that the less-is-more effect can be predicted even if heuristics (enabled when little information is available have relatively low accuracy; this result contradicts current explanations of the effect. A new effect, the below-chance less-is-more effect, is also predicted. Even though the less-is-more effect is predicted to occur frequently, its average magnitude is predicted to be small, as has been found empirically. Finally, I show that current empirical tests of less-is-more-effect predictions have methodological problems and propose a new method. I conclude by examining the assumptions of the imperfect-recognition-memory model used here and of other models in the literature, and by speculating about future research.

  7. Design and Parametric Study of the Magnetic Sensor for Position Detection in Linear Motor Based on Nonlinear Parametric model order reduction.

    Science.gov (United States)

    Paul, Sarbajit; Chang, Junghwan

    2017-07-01

    This paper presents a design approach for a magnetic sensor module to detect mover position using the proper orthogonal decomposition-dynamic mode decomposition (POD-DMD)-based nonlinear parametric model order reduction (PMOR). The parameterization of the sensor module is achieved by using the multipolar moment matching method. Several geometric variables of the sensor module are considered while developing the parametric study. The operation of the sensor module is based on the principle of the airgap flux density distribution detection by the Hall Effect IC. Therefore, the design objective is to achieve a peak flux density (PFD) greater than 0.1 T and total harmonic distortion (THD) less than 3%. To fulfill the constraint conditions, the specifications for the sensor module is achieved by using POD-DMD based reduced model. The POD-DMD based reduced model provides a platform to analyze the high number of design models very fast, with less computational burden. Finally, with the final specifications, the experimental prototype is designed and tested. Two different modes, 90° and 120° modes respectively are used to obtain the position information of the linear motor mover. The position information thus obtained are compared with that of the linear scale data, used as a reference signal. The position information obtained using the 120° mode has a standard deviation of 0.10 mm from the reference linear scale signal, whereas the 90° mode position signal shows a deviation of 0.23 mm from the reference. The deviation in the output arises due to the mechanical tolerances introduced into the specification during the manufacturing process. This provides a scope for coupling the reliability based design optimization in the design process as a future extension.

  8. Change detection in urban and rural driving scenes: Effects of target type and safety relevance on change blindness.

    Science.gov (United States)

    Beanland, Vanessa; Filtness, Ashleigh J; Jeans, Rhiannon

    2017-03-01

    The ability to detect changes is crucial for safe driving. Previous research has demonstrated that drivers often experience change blindness, which refers to failed or delayed change detection. The current study explored how susceptibility to change blindness varies as a function of the driving environment, type of object changed, and safety relevance of the change. Twenty-six fully-licenced drivers completed a driving-related change detection task. Changes occurred to seven target objects (road signs, cars, motorcycles, traffic lights, pedestrians, animals, or roadside trees) across two environments (urban or rural). The contextual safety relevance of the change was systematically manipulated within each object category, ranging from high safety relevance (i.e., requiring a response by the driver) to low safety relevance (i.e., requiring no response). When viewing rural scenes, compared with urban scenes, participants were significantly faster and more accurate at detecting changes, and were less susceptible to "looked-but-failed-to-see" errors. Interestingly, safety relevance of the change differentially affected performance in urban and rural environments. In urban scenes, participants were more efficient at detecting changes with higher safety relevance, whereas in rural scenes the effect of safety relevance has marginal to no effect on change detection. Finally, even after accounting for safety relevance, change blindness varied significantly between target types. Overall the results suggest that drivers are less susceptible to change blindness for objects that are likely to change or move (e.g., traffic lights vs. road signs), and for moving objects that pose greater danger (e.g., wild animals vs. pedestrians). Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Observability of satellite launcher navigation with INS, GPS, attitude sensors and reference trajectory

    Science.gov (United States)

    Beaudoin, Yanick; Desbiens, André; Gagnon, Eric; Landry, René

    2018-01-01

    The navigation system of a satellite launcher is of paramount importance. In order to correct the trajectory of the launcher, the position, velocity and attitude must be known with the best possible precision. In this paper, the observability of four navigation solutions is investigated. The first one is the INS/GPS couple. Then, attitude reference sensors, such as magnetometers, are added to the INS/GPS solution. The authors have already demonstrated that the reference trajectory could be used to improve the navigation performance. This approach is added to the two previously mentioned navigation systems. For each navigation solution, the observability is analyzed with different sensor error models. First, sensor biases are neglected. Then, sensor biases are modelled as random walks and as first order Markov processes. The observability is tested with the rank and condition number of the observability matrix, the time evolution of the covariance matrix and sensitivity to measurement outlier tests. The covariance matrix is exploited to evaluate the correlation between states in order to detect structural unobservability problems. Finally, when an unobservable subspace is detected, the result is verified with theoretical analysis of the navigation equations. The results show that evaluating only the observability of a model does not guarantee the ability of the aiding sensors to correct the INS estimates within the mission time. The analysis of the covariance matrix time evolution could be a powerful tool to detect this situation, however in some cases, the problem is only revealed with a sensitivity to measurement outlier test. None of the tested solutions provide GPS position bias observability. For the considered mission, the modelling of the sensor biases as random walks or Markov processes gives equivalent results. Relying on the reference trajectory can improve the precision of the roll estimates. But, in the context of a satellite launcher, the roll

  10. Early MESSENGER Results for Less Abundant or Weakly Emitting Species in Mercury's Exosphere

    Science.gov (United States)

    Vervack, Ronald J., Jr.; McClintock, William E.; Killen, Rosemary M.; Sprague, Ann L.; Burger, Matthew H.; Merkel, Aimee W.; Sarantos, Menelaos

    2011-01-01

    Now that the Messenger spacecraft is in orbit about Mercury, the extended observing time enables searches for exospheric species that are less abundant or weakly emitting compared with those for which emission has previously been detected. Many of these species cannot be observed from the ground because of terrestrial atmospheric absorption. We report here on the status of MESSENGER orbital-phase searches for additional species in Mercury's exosphere.

  11. Thallium determination in reference materials by isotope dilution mass spectrometry (IDMS) using thermal ionization

    International Nuclear Information System (INIS)

    Waidmann, E.; Hilpert, K.; Stoeppler, M.

    1990-01-01

    Using Isotope Dilution Mass Spectrometry (IDMS) with thermal ionization, thallium concentrations were determined in reference materials from NIST and BCR, from other sources, and reference materials from the German Environmental Specimen Bank 203 Tl spike solution is applied for the isotope dilution technique. Thallium concentrations in the investigated materials range from 2.67 μg Tl.kg -1 to 963 μg Tl.kg -1 with a relative standard deviation from 0.14 to 10%. The detection limit was 0.1 ng thallium for this work. (orig.)

  12. Evaluation of computer-aided detection and dual energy software in detection of peripheral pulmonary embolism on dual-energy pulmonary CT angiography

    International Nuclear Information System (INIS)

    Lee, Choong Wook; Seo, Joon Beom; Song, Jae-Woo; Kim, Mi-Young; Lee, Ha Young; Park, Yang Shin; Chae, Eun Jin; Jang, Yu Mi; Kim, Namkug; Krauss, Bernard

    2011-01-01

    To evaluate the sensitivity of computer-aided detection(CAD) and dual-energy software('Lung PBV', 'Lung Vessels') for detecting peripheral pulmonary embolism(PE). Between Jan-2007 and Jan-2008, 309 patients underwent dual-energy CT angiography(DECTA) for the evaluation of suspected PE. Among them, 37 patients were retrospectively selected; 21 with PE at segmental-or-below levels and 16 without PE according to clinical reports. A standard computer assisted detection (CAD) package and two new types of software('Lung PBV', 'Lung Vessels') were applied on a dedicated workstation. This resulted in four alternative tests for detecting PE: DECTA alone and DECTA with CAD, 'Lung Vessels' and 'Lung PBV'. Two radiologists independently read all cases at different reading sessions. Two thoracic radiologists set the reference standard by combining all information from DECTA and software. The sensitivity of detection for all, segmental and subsegmental-or-below PE were assessed. The reference standard contained 136 PE(segmental 65, subsegmental-or-below 71). With DECTA alone, the sensitivity of detection for all, segmental and subsegmental-or-below pulmonary arteries was 54.5%/73.7%/34.4%; DECTA with CAD, 57.8%/76.8%/37.9%; DECTA with 'Lung PBV', 61.1%/79.9%/41.4%; DECTA with 'Lung Vessels', 64.0%/78.3%/48.5% respectively. The use of CAD, Lung Vessels and Lung PBV shows improved capability to detect peripheral PE. (orig.)

  13. Measurement of polybrominated diphenyl ethers in environmental matrix standard reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Stapleton, H.; Schantz, M.; Wise, S. (National Institute of Standards and Technology)

    2004-09-15

    Polybrominated diphenyl ethers (PBDEs) are a class of emerging contaminants of concern as many studies have now demonstrated that these compounds are bioaccumulative, persistent and increasing in concentration in the environment. PBDEs are being detected in almost every environmental sample examined, and they have even been measured in samples collected in the Arctic, further demonstrating their persistence and potential for long range transport. More and more studies are continuing to examine the fate and transport of these flame retardant compounds in environmental samples and as such, reference materials are needed to provide quality control on these measurements. The National Institute of Standards and Technology (NIST) supports a national Standard Reference Material (SRM) program for measurement of organic contaminants such as PCBs, PAHs and chlorinated pesticides in environmental matrices. This current study was undertaken to provide reference measurements for PBDEs in selected SRMs that are currently used by various laboratories throughout the United States. These SRMs include matrices such as marine mammal blubber, lake trout tissue, mussel tissue, sediment, house dust and human serum. We report here reference values for 22 PBDE congeners that have been quantified in these seven types of SRMs.

  14. Evaluation of the PREVI® Isola automated seeder system compared to reference manual inoculation for antibiotic susceptibility testing by the disk diffusion method.

    Science.gov (United States)

    Le Page, S; van Belkum, A; Fulchiron, C; Huguet, R; Raoult, D; Rolain, J-M

    2015-09-01

    The disk diffusion (DD) method remains the most popular manual technique for antibiotic susceptibility testing (AST) in clinical microbiology laboratories. This is because of its simplicity, reproducibility, and limited cost compared to (automated) microdilution systems, which are usually less sensitive at detecting certain important mechanisms of resistance. Here, we evaluate the PREVI® Isola automated seeder system using a new protocol for spreading bacterial suspensions (eight deposits of calibrated inocula of bacteria, followed by two rounds of rotation) in comparison with manual DD reference testing on a large series of clinical and reference strains. The average time required for seeding one agar plate for DD with this new protocol was 51 s per plate, i.e., 70 agar plates/h. Reproducibility and repeatability was assessed on three reference and three randomly chosen clinical strains, as usually requested by the European Committee on Antimicrobial Susceptibility Testing (EUCAST), and was excellent compared to the manual method. The standard deviations of zones of growth inhibition showed no statistical discrimination. The correlation between the two methods, assessed using 294 clinical isolates and a panel of six antibiotics (n = 3,528 zones of growth inhibition measured), was excellent, with a correlation coefficient of 0.977. The new PREVI® Isola protocol adapted for DD had a sensitivity of 99 % and a specificity of 100 % compared to the manual technique for interpreting DD as recommended by the EUCAST.

  15. Contextual cueing of tactile search is coded in an anatomical reference frame.

    Science.gov (United States)

    Assumpção, Leonardo; Shi, Zhuanghua; Zang, Xuelian; Müller, Hermann J; Geyer, Thomas

    2018-04-01

    This work investigates the reference frame(s) underlying tactile context memory, a form of statistical learning in a tactile (finger) search task. In this task, if a searched-for target object is repeatedly encountered within a stable spatial arrangement of task-irrelevant distractors, detecting the target becomes more efficient over time (relative to nonrepeated arrangements), as learned target-distractor spatial associations come to guide tactile search, thus cueing attention to the target location. Since tactile search displays can be represented in several reference frames, including multiple external and an anatomical frame, in Experiment 1 we asked whether repeated search displays are represented in tactile memory with reference to an environment-centered or anatomical reference frame. In Experiment 2, we went on examining a hand-centered versus anatomical reference frame of tactile context memory. Observers performed a tactile search task, divided into a learning and test session. At the transition between the two sessions, we introduced postural manipulations of the hands (crossed ↔ uncrossed in Expt. 1; palm-up ↔ palm-down in Expt. 2) to determine the reference frame of tactile contextual cueing. In both experiments, target-distractor associations acquired during learning transferred to the test session when the placement of the target and distractors was held constant in anatomical, but not external, coordinates. In the latter, RTs were even slower for repeated displays. We conclude that tactile contextual learning is coded in an anatomical reference frame. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  16. Proposed man-rem reference values of occupational exposure

    International Nuclear Information System (INIS)

    Lombard, J.

    1988-04-01

    This report presents a proposal of referent collective dose (man-rem) values for occupational exposure related to operation of French pressurized water reactors. These values, permitting adequate choice of protection both at design and operation level, are dependent on the level of annual individual doses. The man-rem value, originating from annual individual doses less than 0.5 rem are estimated to 1 kf. The proposed value is 20 kf for annual individual exposures between 0.5 and 3 rem, and 90 kf for annual individual exposures between 3 and 5 rem. (author) [fr

  17. Definition of key parameters for constructing an online reference micrographs collection of processed animal particles in feed

    Directory of Open Access Journals (Sweden)

    Belinchon Crespo, C.

    2012-01-01

    Full Text Available The European Union Reference Laboratory for the detection of animal proteins in feedingstuffs (EURL-AP has developed an online micrographs collection supporting its network activities within the European Union for the detection of prohibited animal by-products in feed. So far, the only official method for detecting these by-products is light microscopy, which is highly dependent on the skills of a microscopist because it relies on particle recognition. In order to help the microscopist network to achieve high proficiency levels, it was necessary to create an online reference tool based on micrographs and accessible via an Intranet platform. Members of the National Reference Laboratories for animal proteins in feedingstuffs (NRL-AP and the International Association for Feedingstuff Analysis – Section Feedingstuff Microscopy (IAG have access to this micrographs collection. This paper describes how the online collection was created and what conditions had to be taken into account in creating such a tool. It also describes how information are periodically updated and managed within the context of the large amount of information included in each micrograph. The need for a robust back-office system as the foundation for all the research activities in this project is also covered, and the evaluation of the use of the online collection is discussed.

  18. Evaluation of 3M molecular detection assay (MDA) Salmonella for the detection of Salmonella in selected foods: collaborative study.

    Science.gov (United States)

    Bird, Patrick; Fisher, Kiel; Boyle, Megan; Huffman, Travis; Benzinger, M Joseph; Bedinghaus, Paige; Flannery, Jonathan; Crowley, Erin; Agin, James; Goins, David; Benesh, DeAnn; David, John

    2013-01-01

    The 3M Molecular Detection Assay (MDA) Salmonella is used with the 3M Molecular Detection System for the detection of Salmonella spp. in food, food-related, and environmental samples after enrichment. The assay utilizes loop-mediated isothermal amplification to rapidly amplify Salmonella target DNA with high specificity and sensitivity, combined with bioluminescence to detect the amplification. The 3M MDA Salmonella method was compared using an unpaired study design in a multilaboratory collaborative study to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG 4.05), Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg and Catfish Products for raw ground beef and the U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) Chapter 5 Salmonella reference method for wet dog food following the current AOAC guidelines. A total of 20 laboratories participated. For the 3M MDA Salmonella method, raw ground beef was analyzed using 25 g test portions, and wet dog food was analyzed using 375 g test portions. For the reference methods, 25 g test portions of each matrix were analyzed. Each matrix was artificially contaminated with Salmonella at three inoculation levels: an uninoculated control level (0 CFU/test portion), a low inoculum level (0.2-2 CFU/test portion), and a high inoculum level (2-5 CFU/test portion). In this study, 1512 unpaired replicate samples were analyzed. Statistical analysis was conducted according to the probability of detection (POD). For the low-level raw ground beef test portions, the following dLPOD (difference between the POD of the reference and candidate method) values with 95% confidence intervals were obtained: -0.01 (-0.14, +0.12). For the low-level wet dog food test portions, the following dLPOD with 95% confidence intervals were obtained: -0.04 (-0.16, +0.09). No significant differences were observed in the number of positive

  19. IAEA biological reference materials

    International Nuclear Information System (INIS)

    Parr, R.M.; Schelenz, R.; Ballestra, S.

    1988-01-01

    The Analytical Quality Control Services programme of the IAEA encompasses a wide variety of intercomparisons and reference materials. This paper reviews only those aspects of the subject having to do with biological reference materials. The 1988 programme foresees 13 new intercomparison exercises, one for major, minor and trace elements, five for radionuclides, and seven for stable isotopes. Twenty-two natural matrix biological reference materials are available: twelve for major, minor and trace elements, six for radionuclides, and four for chlorinated hydrocarbons. Seven new intercomparisons and reference materials are in preparation or under active consideration. Guidelines on the correct use of reference materials are being prepared for publication in 1989 in consultation with other major international producers and users of biological reference materials. The IAEA database on available reference materials is being updated and expanded in scope, and a new publication is planned for 1989. (orig.)

  20. Standard Reference Tables -

    Data.gov (United States)

    Department of Transportation — The Standard Reference Tables (SRT) provide consistent reference data for the various applications that support Flight Standards Service (AFS) business processes and...

  1. Hybrid Intrusion Detection System for DDoS Attacks

    Directory of Open Access Journals (Sweden)

    Özge Cepheli

    2016-01-01

    Full Text Available Distributed denial-of-service (DDoS attacks are one of the major threats and possibly the hardest security problem for today’s Internet. In this paper we propose a hybrid detection system, referred to as hybrid intrusion detection system (H-IDS, for detection of DDoS attacks. Our proposed detection system makes use of both anomaly-based and signature-based detection methods separately but in an integrated fashion and combines the outcomes of both detectors to enhance the overall detection accuracy. We apply two distinct datasets to our proposed system in order to test the detection performance of H-IDS and conclude that the proposed hybrid system gives better results than the systems based on nonhybrid detection.

  2. VEHICLE LOCALIZATION BY LIDAR POINT CORRELATION IMPROVED BY CHANGE DETECTION

    Directory of Open Access Journals (Sweden)

    A. Schlichting

    2016-06-01

    Full Text Available LiDAR sensors are proven sensors for accurate vehicle localization. Instead of detecting and matching features in the LiDAR data, we want to use the entire information provided by the scanners. As dynamic objects, like cars, pedestrians or even construction sites could lead to wrong localization results, we use a change detection algorithm to detect these objects in the reference data. If an object occurs in a certain number of measurements at the same position, we mark it and every containing point as static. In the next step, we merge the data of the single measurement epochs to one reference dataset, whereby we only use static points. Further, we also use a classification algorithm to detect trees. For the online localization of the vehicle, we use simulated data of a vertical aligned automotive LiDAR sensor. As we only want to use static objects in this case as well, we use a random forest classifier to detect dynamic scan points online. Since the automotive data is derived from the LiDAR Mobile Mapping System, we are able to use the labelled objects from the reference data generation step to create the training data and further to detect dynamic objects online. The localization then can be done by a point to image correlation method using only static objects. We achieved a localization standard deviation of about 5 cm (position and 0.06° (heading, and were able to successfully localize the vehicle in about 93 % of the cases along a trajectory of 13 km in Hannover, Germany.

  3. Vehicle Localization by LIDAR Point Correlation Improved by Change Detection

    Science.gov (United States)

    Schlichting, A.; Brenner, C.

    2016-06-01

    LiDAR sensors are proven sensors for accurate vehicle localization. Instead of detecting and matching features in the LiDAR data, we want to use the entire information provided by the scanners. As dynamic objects, like cars, pedestrians or even construction sites could lead to wrong localization results, we use a change detection algorithm to detect these objects in the reference data. If an object occurs in a certain number of measurements at the same position, we mark it and every containing point as static. In the next step, we merge the data of the single measurement epochs to one reference dataset, whereby we only use static points. Further, we also use a classification algorithm to detect trees. For the online localization of the vehicle, we use simulated data of a vertical aligned automotive LiDAR sensor. As we only want to use static objects in this case as well, we use a random forest classifier to detect dynamic scan points online. Since the automotive data is derived from the LiDAR Mobile Mapping System, we are able to use the labelled objects from the reference data generation step to create the training data and further to detect dynamic objects online. The localization then can be done by a point to image correlation method using only static objects. We achieved a localization standard deviation of about 5 cm (position) and 0.06° (heading), and were able to successfully localize the vehicle in about 93 % of the cases along a trajectory of 13 km in Hannover, Germany.

  4. Reevaluation of the NOAA/CMDL carbon monoxide reference scale and comparisons with CO reference gases at NASA-Langley and the Fraunhofer Institut

    Science.gov (United States)

    Novelli, P. C.; Collins, J. E., Jr.; Myers, R. C.; Sachse, G. W.; Scheel, H. E.

    1994-01-01

    The carbon monoxide (CO) reference scale created by the National Oceanic and Atmospheric Administration/Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) is used to quantify measurements of CO in the atmosphere, calibrate standards of other laboratories and to otherwise provide reference gases to the community measuring atmospheric CO. This reference scale was created based upon a set of primary standards prepared by gravimetric methods at CMDL and has been propagated to a set of working standards. In this paper we compare CO mixing ratios assigned to the working standards by three approaches: (1) calibration against the original gravimetric standards, (2) calibration using only working standards as the reference gas, and (3) calibration against three new gravimetric standards prepared to CMDL. The agreement between these values was typically better than 1%. The calibration histories of CMDL working standards are reviewed with respect to expected rates of CO change in the atmosphere. Using a Monte Carlo approach to simulate the effect of drifting standards on calculated mixing ratios, we conclude that the error solely associated with the maintenance of standards will limit the ability to detect small CO changes in the atmosphere. We also report results of intercalibration experiments conducted between CMDL and the Diode Laser Sensor Group (DACOM) at the NASA Langley Research Center (Hampton, Virginia), and CMDL and the Fraunhofer-Institut (Garmisch-Partenkirchen, Germany). Each laboratory calibrated several working standards for CO using their reference gases, and these results were compared to calibrations conducted by CMDL. The intercomparison of eight standards (CO concentrations between approximately 100 and approximately 165 ppb) by CMDL and NASA agreed to better than +/- 2%. The calibration of six standards (CO concentrations between approximately 50 and approximately 210 ppb) by CMDL and the Fraunhofer-Institut agreed to within +/- 2% for four

  5. Continuous growth reference from 24th week of gestation to 24 months by gender

    Directory of Open Access Journals (Sweden)

    Albertsson-Wikland Kerstin

    2008-02-01

    Full Text Available Abstract Background Growth charts and child growth assessment have become prime global instruments in child health practice over the 30 years. An updated, continuous growth standard that bridges size at birth values with postnatal growth values can improve child growth screening and monitoring. Methods This novel growth chart was constructed from two sources of information. Size at birth (weight, length and head circumference reference values were updated based on information of normal deliveries (i.e. singleton live births without severe congenital malformation, with healthy mothers and born vaginally from the Swedish Medical Birth Registry, 1990–1999 (n = 810393. Weight was evaluated using logarithmic transformation as for postnatal weight. Standard deviations were estimated from data within the empirical mean ± 1.0 SD for each gestational week and gender. These values were smoothed by empirical curve-fitting together with values from our recently published postnatal growth reference including 3650 longitudinally followed children from birth to final height 9. Timescale and weight axes were made logarithmic in order to magnify the early time part of the graph. Results This study presents the first continuous gender specific growth chart from birth irrespective of gestational age at birth until 2 years of age for weight, length and head circumference. Birth weight at 40 weeks of gestation increased approximately 100 gram and length increased only 1 mm compared with earlier Swedish reference from 1977–81. The curve is now less S-shaped as compared with earlier curves and compared with 4 curves from other countries and with more constant variation over the whole range. Conclusion Our values picture the unrestricted pattern of growth improving the detection of a deviating growth pattern, when the growth of an individual infant is plotted on the charts. Especially for very preterm infants age corrected growth can be more easily evaluated

  6. Detecting wash trade in the financial market

    OpenAIRE

    Cao, Yi; Li, Yuhua; Coleman, Sonya; Belatreche, Ammar; McGinnity, T. M.

    2014-01-01

    Wash trade refers to the activities of traders who utilise deliberately designed collusive transactions to increase the trading volumes for creating active market impression. Wash trade can be damaging to the proper functioning and integrity of capital markets. Existing work focuses on collusive clique detections based on certain assumptions of trading behaviours. Effective approaches for analysing and detecting wash trade in a real-life market have yet to be developed. T...

  7. Automated detection of exudates for diabetic retinopathy screening

    International Nuclear Information System (INIS)

    Fleming, Alan D; Philip, Sam; Goatman, Keith A; Williams, Graeme J; Olson, John A; Sharp, Peter F

    2007-01-01

    Automated image analysis is being widely sought to reduce the workload required for grading images resulting from diabetic retinopathy screening programmes. The recognition of exudates in retinal images is an important goal for automated analysis since these are one of the indicators that the disease has progressed to a stage requiring referral to an ophthalmologist. Candidate exudates were detected using a multi-scale morphological process. Based on local properties, the likelihoods of a candidate being a member of classes exudate, drusen or background were determined. This leads to a likelihood of the image containing exudates which can be thresholded to create a binary decision. Compared to a clinical reference standard, images containing exudates were detected with sensitivity 95.0% and specificity 84.6% in a test set of 13 219 images of which 300 contained exudates. Depending on requirements, this method could form part of an automated system to detect images showing either any diabetic retinopathy or referable diabetic retinopathy

  8. Automated detection of exudates for diabetic retinopathy screening

    Energy Technology Data Exchange (ETDEWEB)

    Fleming, Alan D [Biomedical Physics, University of Aberdeen, Aberdeen, AB25 2ZD (United Kingdom); Philip, Sam [Diabetes Retinal Screening Service, David Anderson Building, Foresterhill Road, Aberdeen, AB25 2ZP (United Kingdom); Goatman, Keith A [Biomedical Physics, University of Aberdeen, Aberdeen, AB25 2ZD (United Kingdom); Williams, Graeme J [Diabetes Retinal Screening Service, David Anderson Building, Foresterhill Road, Aberdeen, AB25 2ZP (United Kingdom); Olson, John A [Diabetes Retinal Screening Service, David Anderson Building, Foresterhill Road, Aberdeen, AB25 2ZP (United Kingdom); Sharp, Peter F [Biomedical Physics, University of Aberdeen, Aberdeen, AB25 2ZD (United Kingdom)

    2007-12-21

    Automated image analysis is being widely sought to reduce the workload required for grading images resulting from diabetic retinopathy screening programmes. The recognition of exudates in retinal images is an important goal for automated analysis since these are one of the indicators that the disease has progressed to a stage requiring referral to an ophthalmologist. Candidate exudates were detected using a multi-scale morphological process. Based on local properties, the likelihoods of a candidate being a member of classes exudate, drusen or background were determined. This leads to a likelihood of the image containing exudates which can be thresholded to create a binary decision. Compared to a clinical reference standard, images containing exudates were detected with sensitivity 95.0% and specificity 84.6% in a test set of 13 219 images of which 300 contained exudates. Depending on requirements, this method could form part of an automated system to detect images showing either any diabetic retinopathy or referable diabetic retinopathy.

  9. Automated detection of exudates for diabetic retinopathy screening

    Science.gov (United States)

    Fleming, Alan D.; Philip, Sam; Goatman, Keith A.; Williams, Graeme J.; Olson, John A.; Sharp, Peter F.

    2007-12-01

    Automated image analysis is being widely sought to reduce the workload required for grading images resulting from diabetic retinopathy screening programmes. The recognition of exudates in retinal images is an important goal for automated analysis since these are one of the indicators that the disease has progressed to a stage requiring referral to an ophthalmologist. Candidate exudates were detected using a multi-scale morphological process. Based on local properties, the likelihoods of a candidate being a member of classes exudate, drusen or background were determined. This leads to a likelihood of the image containing exudates which can be thresholded to create a binary decision. Compared to a clinical reference standard, images containing exudates were detected with sensitivity 95.0% and specificity 84.6% in a test set of 13 219 images of which 300 contained exudates. Depending on requirements, this method could form part of an automated system to detect images showing either any diabetic retinopathy or referable diabetic retinopathy.

  10. Detection and quantification limits: basic concepts, international harmonization, and outstanding ('low-level') issues

    International Nuclear Information System (INIS)

    Currie, L.A.

    2004-01-01

    A brief review is given of concepts, basic definitions, and terminology for metrological detection and quantification capabilities, representing harmonized recommendations and norms of the International Union of Pure and Applied Chemistry (IUPAC) and the International Organization for Standardization (ISO), respectively. Treatment of the (low-level) blank and variance function are discussed in some detail, together with special problems arising with detection decisions and the reporting of low-level data. Key references to the international documents follow, as well as specialized references addressing very low-level counting data, skewed environmental blank distributions, and multiple and multivariate detection decisions

  11. A method to calibrate a solar pyranometer for measuring reference diffuse irradiance

    Energy Technology Data Exchange (ETDEWEB)

    Reda, I.; Stoffel, T.; Myers, D. [National Renewable Energy Laboratory, Golden, CO (United States)

    2003-02-01

    Accurate pyranometer calibrations, traceable to internationally recognized standards, are critical for solar irradiance measurements. One calibration method is the component summation, where the pyranometers are calibrated outdoors under clear sky conditions, and the reference global solar irradiance is calculated as the sum of two reference components, the diffuse and subtended beam solar irradiances. The beam component is measured with pyrheliometers traceable to the World Radiometric Reference, while there is no internationally recognized reference for the diffuse component. In the absence of such a reference, we present a method to consistently calibrate pyranometers for measuring the diffuse component with an estimated uncertainty of {+-} (3% of reading +1 W/m{sup 2}). The method is based on using a modified shade/unshade method, and pyranometers with less than 1 W/m{sup 2} thermal offset errors. We evaluated the consistency of our method by calibrating three pyranometers four times. Calibration results show that the responsivity change is within {+-} 0.52% for the three pyranometers. We also evaluated the effect of calibrating pyranometers unshaded, then using them shaded to measure diffuse irradiance. We calibrated three unshaded pyranometers using the component summation method. Their outdoor measurements of clear sky diffuse irradiance, from sunrise to sundown, showed that the three calibrated pyranometers can be used to measure the diffuse irradiance to within {+-} 1.4 W/m{sup 2} variation from the reference irradiance. (author)

  12. Capillary electrophoresis with indirect UV detection for the determination of stabilizers and citrates present in human albumin solutions.

    Science.gov (United States)

    Jaworska, Małgorzata; Cygan, Paulina; Wilk, Małgorzata; Anuszewska, Elzbieta

    2009-08-15

    Sodium caprylate and N-acetyltryptophan are the most frequently used stabilizers that protect the albumin from aggregation or heat induced denaturation. In turn citrates - excipients remaining after fractionation process - can be treated as by-product favoring leaching aluminum out of glass containers whilst albumin solution is stored. With ionic nature these substances have all the markings of a subject for capillary electrophoresis analysis. Thus CE methods were proposed as new approach for quality control of human albumin solution in terms of determination of stabilizers and citrates residue. Human albumin solutions both 5% and 20% from various manufacturers were tested. Indirect detection mode was set to provide sufficient detectability of analytes lacking of chromophores. As being anions analytes were separated with reversed electroosmotic flow. As a result of method optimization two background electrolytes based on p-hydroxybenzoic acid and 2,6-pyridinedicarboxylic acid were selected for stabilizers and citrates separation, respectively. The optimized methods were successfully validated. For citrates that require quantification below 100microM the method demonstrated the precision less than 4% and the limit of detection at 4microM. In order to check the new methods accuracy and applicability the samples were additionally tested with selected reference methods. The proposed methods allow reliable quantification of stabilizers and citrates in human albumin solution that was confirmed by method validation as well as result comparison with reference methods. The CE methods are considered to be suitable for quality control yet simplifying and reducing cost of analysis.

  13. Analytical modeling of split-gate junction-less transistor for a biosensor application

    Directory of Open Access Journals (Sweden)

    Shradhya Singh

    2018-04-01

    Full Text Available This paper represents the analytical modeling of split-gate Dielectric Modulated Junction Less Transistor (JLT for label free electrical detection of bio molecules. Some part of the channel region is opened for providing the binding sites for the bio molecules unlike conventional MOSFET which is enclosed with the gate electrode. Due to this open area, the surface potential of this region affected by the charged and neutral bio molecules immobilized to the open region of channel. Surface potential of the channel region obtained by solving two-Dimensional Poisson's equation by potential profile having parabolic nature through channel region using technique called conformal mapping. By deriving the surface potential model, derivation of threshold model can also be done. For the detection of bio molecule, variation in to the threshold voltage due to binding of bio molecule in the gate underlap region is the sensing metric.

  14. Development and application of a multi-targeting reference plasmid as calibrator for analysis of five genetically modified soybean events.

    Science.gov (United States)

    Pi, Liqun; Li, Xiang; Cao, Yiwei; Wang, Canhua; Pan, Liangwen; Yang, Litao

    2015-04-01

    Reference materials are important in accurate analysis of genetically modified organism (GMO) contents in food/feeds, and development of novel reference plasmid is a new trend in the research of GMO reference materials. Herein, we constructed a novel multi-targeting plasmid, pSOY, which contained seven event-specific sequences of five GM soybeans (MON89788-5', A2704-12-3', A5547-127-3', DP356043-5', DP305423-3', A2704-12-5', and A5547-127-5') and sequence of soybean endogenous reference gene Lectin. We evaluated the specificity, limit of detection and quantification, and applicability of pSOY in both qualitative and quantitative PCR analyses. The limit of detection (LOD) was as low as 20 copies in qualitative PCR, and the limit of quantification (LOQ) in quantitative PCR was 10 copies. In quantitative real-time PCR analysis, the PCR efficiencies of all event-specific and Lectin assays were higher than 90%, and the squared regression coefficients (R(2)) were more than 0.999. The quantification bias varied from 0.21% to 19.29%, and the relative standard deviations were from 1.08% to 9.84% in simulated samples analysis. All the results demonstrated that the developed multi-targeting plasmid, pSOY, was a credible substitute of matrix reference materials, and could be used as a reliable reference calibrator in the identification and quantification of multiple GM soybean events.

  15. TMAP: A NEO follow-up program utilizing undergraduate observers

    Science.gov (United States)

    Ramirez, C.; Deaver, D.; Martinez, R.; Foster, J.; Kuang, L.; Ates, A.; Anderson, M.; Mijac, M.; Gillam, S.; Hicks, M. D.

    2000-10-01

    In the spring of 2000 we began TMAP (Table Mountain Astrometry Project), a program designed to provide timely astrometric followup of newly discovered near-Earth asteroids. Relying on undergraduate observers from the local California State Universities, we have to date been involved with the over 50 NEO and new comet discoveries. This is a significant fraction of all near-Earth asteroids discovered over the time period. All observations are performed at JPL's Table Mountain Facility near Wrightwood California using the 0.6-meter telescope equipped with a Photometrics LN cooled 1k CCD mounted at the cassegrain focus. With this system we can routinely detect objects to R=20.5. We have typically scheduled two runs per month on weekends bracketing the new moon. The student observers man the telescope are trained to select and obtain R-band images of candidates from the Minor Planet Center's NEO Confirmation Page (http://cfa-www.harvard.edu/cfa/ps/NEO/TheNEOPage.html). The astrometry is then reduced and submitted to the Minor Planet Center the following day. TMAP has proven to be an efficient way both to obtain much needed astrometric measurements of newly discovered small bodies as well as to involve undergraduate researchers in planetary research. The limiting magnitudes provided by the 0.6-meter partially fills the gap between the extremely helpful and dedicated amateur astromitrists and the followup that the NEO detection programs do themselves. This work is supported by NASA.

  16. Cancer Detection and Diagnosis Methods - Annual Plan

    Science.gov (United States)

    Early cancer detection is a proven life-saving strategy. Learn about the research opportunities NCI supports, including liquid biopsies and other less-invasive methods, for detecting early cancers and precancerous growths.

  17. Orbits of massive satellite galaxies - II. Bayesian estimates of the Milky Way and Andromeda masses using high-precision astrometry and cosmological simulations

    Science.gov (United States)

    Patel, Ekta; Besla, Gurtina; Mandel, Kaisey

    2017-07-01

    In the era of high-precision astrometry, space observatories like the Hubble Space Telescope (HST) and Gaia are providing unprecedented 6D phase-space information of satellite galaxies. Such measurements can shed light on the structure and assembly history of the Local Group, but improved statistical methods are needed to use them efficiently. Here we illustrate such a method using analogues of the Local Group's two most massive satellite galaxies, the Large Magellanic Cloud (LMC) and Triangulum (M33), from the Illustris dark-matter-only cosmological simulation. We use a Bayesian inference scheme combining measurements of positions, velocities and specific orbital angular momenta (j) of the LMC/M33 with importance sampling of their simulated analogues to compute posterior estimates of the Milky Way (MW) and Andromeda's (M31) halo masses. We conclude that the resulting host halo mass is more susceptible to bias when using measurements of the current position and velocity of satellites, especially when satellites are at short-lived phases of their orbits (I.e. at pericentre). Instead, the j value of a satellite is well conserved over time and provides a more reliable constraint on host mass. The inferred virial mass of the MW (M31) using j of the LMC (M33) is {{M}}_{vir, MW} = 1.02^{+0.77}_{-0.55} × 10^{12} M⊙ ({{M}}_{vir, M31} = 1.37^{+1.39}_{-0.75} × 10^{12} M⊙). Choosing simulated analogues whose j values are consistent with the conventional picture of a previous (<3 Gyr ago), close encounter (<100 kpc) of M33 about M31 results in a very low virial mass for M31 (˜1012 M⊙). This supports the new scenario put forth in Patel, Besla & Sohn, wherein M33 is on its first passage about M31 or on a long-period orbit. We conclude that this Bayesian inference scheme, utilizing satellite j, is a promising method to reduce the current factor of 2 spread in the mass range of the MW and M31. This method is easily adaptable to include additional satellites as new 6D

  18. Choice of reference sequence and assembler for alignment of Listeria monocytogenes short-read sequence data greatly influences rates of error in SNP analyses.

    Directory of Open Access Journals (Sweden)

    Arthur W Pightling

    Full Text Available The wide availability of whole-genome sequencing (WGS and an abundance of open-source software have made detection of single-nucleotide polymorphisms (SNPs in bacterial genomes an increasingly accessible and effective tool for comparative analyses. Thus, ensuring that real nucleotide differences between genomes (i.e., true SNPs are detected at high rates and that the influences of errors (such as false positive SNPs, ambiguously called sites, and gaps are mitigated is of utmost importance. The choices researchers make regarding the generation and analysis of WGS data can greatly influence the accuracy of short-read sequence alignments and, therefore, the efficacy of such experiments. We studied the effects of some of these choices, including: i depth of sequencing coverage, ii choice of reference-guided short-read sequence assembler, iii choice of reference genome, and iv whether to perform read-quality filtering and trimming, on our ability to detect true SNPs and on the frequencies of errors. We performed benchmarking experiments, during which we assembled simulated and real Listeria monocytogenes strain 08-5578 short-read sequence datasets of varying quality with four commonly used assemblers (BWA, MOSAIK, Novoalign, and SMALT, using reference genomes of varying genetic distances, and with or without read pre-processing (i.e., quality filtering and trimming. We found that assemblies of at least 50-fold coverage provided the most accurate results. In addition, MOSAIK yielded the fewest errors when reads were aligned to a nearly identical reference genome, while using SMALT to align reads against a reference sequence that is ∼0.82% distant from 08-5578 at the nucleotide level resulted in the detection of the greatest numbers of true SNPs and the fewest errors. Finally, we show that whether read pre-processing improves SNP detection depends upon the choice of reference sequence and assembler. In total, this study demonstrates that researchers

  19. Less is more? Think again! A cognitive fluency-based more-less asymmetry in comparative communication.

    Science.gov (United States)

    Hoorens, Vera; Bruckmüller, Susanne

    2015-11-01

    Differences between groups, individuals, or objects can be framed in multiple ways. One can, for instance, say that men generally earn more than women or that women generally earn less than men. Showing that these logically equivalent expressions are not psychologically equivalent, we demonstrate a robust more-less asymmetry in the use of and responses to comparative statements. More specifically, we show that people use "more than" statements more often than "less than" statements (Study 1); like "more than" statements better (Studies 2 and 3), agree more with opinions expressed through "more than" statements (Studies 4 and 5), and are more likely to consider factual "more than" statements to be true (Study 6). Supporting a cognitive fluency explanation, a manipulation that makes people expect disfluency while processing "less than" statements reduces this otherwise robust more-less asymmetry (Study 7). By combining comparative framing effects with cognitive fluency, the present research brings together 2 research fields in social cognition, shedding new light on both. (c) 2015 APA, all rights reserved).

  20. Comparison of 16-row multislice CT angiography with conventional angiography for detection and evaluation of intracranial aneurysms

    International Nuclear Information System (INIS)

    Donmez, Halil; Serifov, Elman; Kahriman, Guven; Mavili, Ertugrul; Durak, Ahmet Candan; Menkue, Ahmet

    2011-01-01

    Purpose: The aim of this study is to compare the diagnostic performance of 16-row computed tomographic angiography (MDCTA) with digital subtraction angiography (DSA) for the detection and characterization of intracranial aneurysms in patients with nontraumatic subarachnoid hemorrhages (SAH). Materials and methods: One-hundred and twelve consecutive patients with suspected intracranial aneurysm underwent both 16-row MDCTA and DSA. The MDCT angiograms were interpreted in a blinded fashion by using combination with VRI, MIP and MPR techniques. Sensitivity specificity and accuracy were calculated for the CTA and DSA. The results were compared with each other. The DSA reader's interpretation was accepted as the reference standard. Results: A total of 164 aneurysms were detected at DSA in 112 patients, no aneurysms were detected by DSA and MDCTA in 16 patients. Eight aneurysms were missed by MDCTA. The overall sensitivity, specificity, and accuracy of MDCTA on a per-aneurysm basis were 95.1%, 94.1%, and 95%, respectively. According to the size of the aneurysm less than 3 mm; sensitivity, specificity and diagnostic accuracy of MDCTA were 86.1%, 94.1%, 88.6%, respectively. Conclusion: This study suggests that MDCTA is equally as sensitive as DSA in the detection of intracranial aneurysms of greater than 3 mm, and it also reveals 100% detection rate for ruptured aneurysms.

  1. Element content and particle size characterization of a mussel candidate reference material

    International Nuclear Information System (INIS)

    Moreira, Edson G.; Vasconcellos, Marina B.A.; Santos, Rafaela G. dos; Martinelli, Jose R.

    2011-01-01

    The use of certified reference materials is an important tool in the quality assurance of analytical measurements. To assure reliability on recently prepared powder reference materials, not only the characterization of the property values of interest and their corresponding uncertainties, but also physical properties such as the particle size distribution must be well evaluated. Narrow particle size distributions are preferable than larger ones; as different size particles may have different analyte content. Due to this fact, the segregation of the coarse and the fine particles in a bottle may lead to inhomogeneity of the reference material, which should be avoided. In this study the element content as well as the particle size distribution of a mussel candidate reference material produced at IPEN-CNEN/SP was investigated. Instrumental Neutron Activation Analysis was applied to the determination of 15 elements in seven fractions of the material with different particle size distributions. Subsamples of the materials were irradiated simultaneously with elemental standards at the IEA-R1 research nuclear reactor and the induced gamma ray energies were measured in a hyperpure germanium detector. Three vials of the candidate reference material and three coarser fractions, collected during the preparation, were analyzed by Laser Diffraction Particle Analysis to determine the particle size distribution. Differences on element content were detected for fractions with different particle size distribution, indicating the importance of particle size control for biological reference materials. From the particle size analysis, Gaussian particle size distribution was observed for the candidate reference material with mean particle size μ = 94.6 ± 0.8 μm. (author)

  2. Detection of perimacular red dots and blots when screening for diabetic retinopathy: Refer or not refer?

    Science.gov (United States)

    Baltatescu, Anatolie; Striglia, Elio; Trento, Marina; Mazzeo, Aurora; Cavallo, Franco; Charrier, Lorena; Porta, Massimo

    2018-05-01

    Detection of microaneurysms and/or microhaemorrhages near the fovea when screening for diabetic retinopathy poses a problem because referral to retinal specialists may alarm patients and unnecessarily burden ophthalmologists. Six-month prospective study of patients found to have minimal red lesions within one disc diameter of the fovea when screened for diabetic retinopathy. Two 45° digital photographs, one centred on the macula and the other nasal including the optic disc, were taken for each eye. All patients received a 6-month re-screening appointment. Out of 70 patients, 41 returned for re-screening. Diabetic retinopathy had worsened in 3 who required referral but no treatment, was unchanged in 19 and was undetectable in the other 19. Haemoglobin A1c decreased from 7.76% ± 1.50% (61.3 ± 16.2 mmol/mol) to 6.93% ± 1.7% (52.3 ± 18.9 mmol/mol) in the patients in whom diabetic retinopathy worsened but did not change in the other groups. Baseline haemoglobin A1c ( p = 0.048) and systolic blood pressure ( p = 0.007) were lower in the patients in whom diabetic retinopathy improved, but a multivariate model including haemoglobin A1c, blood pressure and known disease duration could not identify any independent risk factor. Minimal red lesions near the fovea, though commanding early re-screening, do not require immediate referral to retinal specialists.

  3. The company objects keep: Linking referents together during cross-situational word learning.

    Science.gov (United States)

    Zettersten, Martin; Wojcik, Erica; Benitez, Viridiana L; Saffran, Jenny

    2018-04-01

    Learning the meanings of words involves not only linking individual words to referents but also building a network of connections among entities in the world, concepts, and words. Previous studies reveal that infants and adults track the statistical co-occurrence of labels and objects across multiple ambiguous training instances to learn words. However, it is less clear whether, given distributional or attentional cues, learners also encode associations amongst the novel objects. We investigated the consequences of two types of cues that highlighted object-object links in a cross-situational word learning task: distributional structure - how frequently the referents of novel words occurred together - and visual context - whether the referents were seen on matching backgrounds. Across three experiments, we found that in addition to learning novel words, adults formed connections between frequently co-occurring objects. These findings indicate that learners exploit statistical regularities to form multiple types of associations during word learning.

  4. Reference miRNAs for miRNAome analysis of urothelial carcinomas.

    Directory of Open Access Journals (Sweden)

    Nadine Ratert

    Full Text Available BACKGROUND/OBJECTIVE: Reverse transcription quantitative real-time PCR (RT-qPCR is widely used in microRNA (miRNA expression studies on cancer. To compensate for the analytical variability produced by the multiple steps of the method, relative quantification of the measured miRNAs is required, which is based on normalization to endogenous reference genes. No study has been performed so far on reference miRNAs for normalization of miRNA expression in urothelial carcinoma. The aim of this study was to identify suitable reference miRNAs for miRNA expression studies by RT-qPCR in urothelial carcinoma. METHODS: Candidate reference miRNAs were selected from 24 urothelial carcinoma and normal bladder tissue samples by miRNA microarrays. The usefulness of these candidate reference miRNAs together with the commonly for normalization purposes used small nuclear RNAs RNU6B, RNU48, and Z30 were thereafter validated by RT-qPCR in 58 tissue samples and analyzed by the algorithms geNorm, NormFinder, and BestKeeper. PRINCIPAL FINDINGS: Based on the miRNA microarray data, a total of 16 miRNAs were identified as putative reference genes. After validation by RT-qPCR, miR-101, miR-125a-5p, miR-148b, miR-151-5p, miR-181a, miR-181b, miR-29c, miR-324-3p, miR-424, miR-874, RNU6B, RNU48, and Z30 were used for geNorm, NormFinder, and BestKeeper analyses that gave different combinations of recommended reference genes for normalization. CONCLUSIONS: The present study provided the first systematic analysis for identifying suitable reference miRNAs for miRNA expression studies of urothelial carcinoma by RT-qPCR. Different combinations of reference genes resulted in reliable expression data for both strongly and less strongly altered miRNAs. Notably, RNU6B, which is the most frequently used reference gene for miRNA studies, gave inaccurate normalization. The combination of four (miR-101, miR-125a-5p, miR-148b, and miR-151-5p or three (miR-148b, miR-181b, and miR-874

  5. Plagiarism Detection Based on SCAM Algorithm

    DEFF Research Database (Denmark)

    Anzelmi, Daniele; Carlone, Domenico; Rizzello, Fabio

    2011-01-01

    Plagiarism is a complex problem and considered one of the biggest in publishing of scientific, engineering and other types of documents. Plagiarism has also increased with the widespread use of the Internet as large amount of digital data is available. Plagiarism is not just direct copy but also...... paraphrasing, rewording, adapting parts, missing references or wrong citations. This makes the problem more difficult to handle adequately. Plagiarism detection techniques are applied by making a distinction between natural and programming languages. Our proposed detection process is based on natural language...... document. Our plagiarism detection system, like many Information Retrieval systems, is evaluated with metrics of precision and recall....

  6. Rapid islanding detection using multi-level inverter for grid-interactive PV system

    International Nuclear Information System (INIS)

    Tsang, K.M.; Chan, W.L.

    2014-01-01

    Graphical abstract: - Highlights: • Novel reference signal is used to form an islanding detection scheme for PV system. • Supply fixed magnitude sinusoidal signal even if utility grid is disconnected. • Seamless transfer between grid-connected and stand-alone modes is possible. - Abstract: A novel reference signal generator is combined with a multi-level inverter to form a rapid islanding detection scheme for grid-interactive PV system. The reference signal generator can easily be synchronized with the utility grid signal and produced a fixed magnitude and very low total harmonic distortion (THD) sinusoidal signal which is in phase with the utility grid signal. Unlike conventional phase-locked loop (PLL) circuitry, the reference signal generator can also provide a fixed magnitude sinusoidal signal even if the utility grid is disconnected and automatically re-synchronous with the grid rapidly. Consequently, seamless transfer between grid-connected and stand-alone modes could easily be achieved if anti-islanding protection is not required. If a saturation element is applied to the raw reference signal followed by the synthesis of the truncated signal using a multi-level inverter, the distinct flat-top feature of the synthesized signal can quickly and easily be identified if the network is in islanding mode at the point of common coupling. Experimental results are included to demonstrate the effectiveness of the proposed detection scheme

  7. Neutral iron densities in front of a reference limiter in TEXTOR

    International Nuclear Information System (INIS)

    Schweer, B.; Bay, H.L.

    1983-09-01

    Preliminary measurements of the time and space resolved densities of neutral iron in front of a reference limiter in Textor have been performed using laser induced fluorescence. The limiter was made of stainless steel (SS 316) and formed as a half sphere, 10 cm in diameter. Neutral iron densities up to 5 x 10 9 atoms/cm 3 were found. The detection limit was below 10 7 atoms/cm 3 . (orig.)

  8. Development of potential selective and reversible pyrazoline based MAO-B inhibitors as MAO-B PET tracer precursors and reference substances for the early detection of Alzheimer's disease.

    Science.gov (United States)

    Neudorfer, Catharina; Shanab, Karem; Jurik, Andreas; Schreiber, Veronika; Neudorfer, Carolina; Vraka, Chrysoula; Schirmer, Eva; Holzer, Wolfgang; Ecker, Gerhard; Mitterhauser, Markus; Wadsak, Wolfgang; Spreitzer, Helmut

    2014-09-15

    Since high MAO-B levels are present in early stages of AD, the MAO-B system can be designated as an appropriate and prospective tracer target of molecular imaging biomarkers for the detection of early AD. According to the preceding investigations of Mishra et al. the aim of this work was the development of a compound library of selective and reversible MAO-B inhibitors by performing bioisosteric modifications of the core structure of 3-(anthracen-9-yl)-5-phenyl-4,5-dihydro-1H-pyrazoles. In conclusion, 13 new pyrazoline based derivatives have been prepared, which will serve as precursor substances for future radiolabeling as well as reference compounds for the investigation of increased MAO-B levels in AD. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. [Coping with everyday stress in different problem areas- comparison of clinically referred and healthy adolescents].

    Science.gov (United States)

    Escher, Fabian; Seiffge-Krenke, Inge

    2013-09-01

    Studies are lacking that analyze how clinically referred adolescents and healthy adolescents cope with everyday stressors. Clinically referred adolescents from three problematic domains (diverse disorders including delinquency, drug abuse, and depression) were compared to healthy adolescents using the Coping Across Situations Questionnaire (Seiffge-Krenke, 1995) and a short version of the Youth Self-Report (Achenbach, 1991). The different clinical groups (n = 469) showed unique patterns concerning their coping styles. The group of depressed youth altogether showed lower coping activities. The youth from institutions for drug abusive youth used more dysfunctional coping. The adolescents from youth welfare services (diverse disorders including delinquency) were more active in both dysfunctional and functional coping than the other two clinically referred groups. The control group showed more functional and less dysfunctional coping. The clinically referred adolescents did not differentiate in their coping behavior, depending on the type of stressor. Gender effects were apparent, albeit negligible. Clinically referred youth are unable to adapt their coping behavior according to the given situation.

  10. Determination of caffeine, theobromine, and theophylline in standard reference material 2384, baking chocolate, using reversed-phase liquid chromatography.

    Science.gov (United States)

    Thomas, Jeanice Brown; Yen, James H; Schantz, Michele M; Porter, Barbara J; Sharpless, Katherine E

    2004-06-02

    A rapid and selective isocratic reversed-phase liquid chromatographic method has been developed at the National Institute of Standards and Technology to simultaneously measure caffeine, theobromine, and theophylline in a food-matrix standard reference material (SRM) 2384, Baking Chocolate. The method uses isocratic elution with a mobile phase composition (volume fractions) of 10% acetronitrile/90% water (pH adjusted to 2.5 using acetic acid) at a flow rate of 1.5 mL/min with ultraviolet absorbance detection (274 nm). Total elution time for these analytes is less than 15 min. Concentration levels of caffeine, theobromine, and theophylline were measured in single 1-g samples taken from each of eight bars of chocolate over an eight-day period. Samples were defatted with hexane, and beta-hydroxyethyltheophylline was added as the internal standard. The repeatability for the caffeine, theobromine, and theophylline measurements was 5.1, 2.3, and 1.9%, respectively. The limit of quantitation for all analytes was theobromine, and theophylline in SRM 2384.

  11. Reference dose levels for dental panoramic radiography in Gwangju (South Korea)

    International Nuclear Information System (INIS)

    Lee, J. S.; Kim, Y. H.; Yoon, S. J.; Kang, B. C.

    2010-01-01

    This study assessed the reference dose levels for dental panoramic radiography in Gwangju city (South Korea) based on the dose width product (DWP) and compared them with those already established elsewhere. A total of 44 panoramic dental radiographic sets (36 digital and 8 analogue panoramic sets) in 41 dental clinics in Gwangju city were chosen. The third quartile DWP was determined from 429 surface dose measurements of the adult surface dose in panoramic dental radiography. The third quartile DWP for panoramic radiography was 60.1 mGy mm. The proposed DWP reference levels of 60.1 mGy mm were less than or equal to those previously reported in other countries, such as Italy and UK, and acceptable for panoramic radiography in Gwangju (KR). (authors)

  12. Changing quantum reference frames

    OpenAIRE

    Palmer, Matthew C.; Girelli, Florian; Bartlett, Stephen D.

    2013-01-01

    We consider the process of changing reference frames in the case where the reference frames are quantum systems. We find that, as part of this process, decoherence is necessarily induced on any quantum system described relative to these frames. We explore this process with examples involving reference frames for phase and orientation. Quantifying the effect of changing quantum reference frames serves as a first step in developing a relativity principle for theories in which all objects includ...

  13. Computer-aided detection of brain metastasis on 3D MR imaging: Observer performance study.

    Directory of Open Access Journals (Sweden)

    Leonard Sunwoo

    Full Text Available To assess the effect of computer-aided detection (CAD of brain metastasis (BM on radiologists' diagnostic performance in interpreting three-dimensional brain magnetic resonance (MR imaging using follow-up imaging and consensus as the reference standard.The institutional review board approved this retrospective study. The study cohort consisted of 110 consecutive patients with BM and 30 patients without BM. The training data set included MR images of 80 patients with 450 BM nodules. The test set included MR images of 30 patients with 134 BM nodules and 30 patients without BM. We developed a CAD system for BM detection using template-matching and K-means clustering algorithms for candidate detection and an artificial neural network for false-positive reduction. Four reviewers (two neuroradiologists and two radiology residents interpreted the test set images before and after the use of CAD in a sequential manner. The sensitivity, false positive (FP per case, and reading time were analyzed. A jackknife free-response receiver operating characteristic (JAFROC method was used to determine the improvement in the diagnostic accuracy.The sensitivity of CAD was 87.3% with an FP per case of 302.4. CAD significantly improved the diagnostic performance of the four reviewers with a figure-of-merit (FOM of 0.874 (without CAD vs. 0.898 (with CAD according to JAFROC analysis (p < 0.01. Statistically significant improvement was noted only for less-experienced reviewers (FOM without vs. with CAD, 0.834 vs. 0.877, p < 0.01. The additional time required to review the CAD results was approximately 72 sec (40% of the total review time.CAD as a second reader helps radiologists improve their diagnostic performance in the detection of BM on MR imaging, particularly for less-experienced reviewers.

  14. Visual Inspection for Caries Detection

    DEFF Research Database (Denmark)

    Gimenez, T; Piovesan, C; Braga, M M

    2015-01-01

    July 2014 to identify published and nonpublished studies in English. Studies of visual inspection were included that 1) assessed accuracy of the method in detecting caries lesions; 2) were performed on occlusal, proximal, or free smooth surfaces in primary or permanent teeth; 3) had a reference...... (from 5,808 articles initially identified) and 1 abstract (from 168) met the inclusion criteria. In general, the analysis demonstrated that the visual method had good accuracy for detecting caries lesions. Although laboratory and clinical studies have presented similar accuracy, clinically obtained...... caries detection method has good overall performance. Furthermore, although the identified studies had high heterogeneity and risk of bias, the use of detailed and validated indices seems to improve the accuracy of the method....

  15. The Mosaic Ancestry of the Drosophila Genetic Reference Panel and the D. melanogaster Reference Genome Reveals a Network of Epistatic Fitness Interactions

    Science.gov (United States)

    Pool, John E.

    2015-01-01

    North American populations of Drosophila melanogaster derive from both European and African source populations, but despite their importance for genetic research, patterns of ancestry along their genomes are largely undocumented. Here, I infer geographic ancestry along genomes of the Drosophila Genetic Reference Panel (DGRP) and the D. melanogaster reference genome, which may have implications for reference alignment, association mapping, and population genomic studies in Drosophila. Overall, the proportion of African ancestry was estimated to be 20% for the DGRP and 9% for the reference genome. Combining my estimate of admixture timing with historical records, I provide the first estimate of natural generation time for this species (approximately 15 generations per year). Ancestry levels were found to vary strikingly across the genome, with less African introgression on the X chromosome, in regions of high recombination, and at genes involved in specific processes (e.g., circadian rhythm). An important role for natural selection during the admixture process was further supported by evidence that many unlinked pairs of loci showed a deficiency of Africa–Europe allele combinations between them. Numerous epistatic fitness interactions may therefore exist between African and European genotypes, leading to ongoing selection against incompatible variants. By focusing on hubs in this network of fitness interactions, I identified a set of interacting loci that include genes with roles in sensation and neuropeptide/hormone reception. These findings suggest that admixed D. melanogaster samples could become an important study system for the genetics of early-stage isolation between populations. PMID:26354524

  16. Preparation of reference material for organochlorine pesticides in a herbal matrix.

    Science.gov (United States)

    Wong, Yiu Chung; Wong, Siu Kay; Kam, Tat Ting

    2008-12-01

    The development of reference material for four organochlorine pesticides, namely hexachlorobenzene and three isomers of hexachlorocyclohexane (alpha-hexachlorocyclohexane, beta-hexachlorocyclohexane and gamma-hexachlorocyclohexane), in a ginseng root sample is presented. Raw materials (Panax ginseng) were purchased from a local market and confirmed to contain certain levels of incurred organochlorine pesticide residues by a validated gas chromatography-mass selective detection method. A total of more than 300 bottles each containing 25 g of samples were prepared after the materials had been freeze-dried, milled and thoroughly mixed. The homogeneity and stability of samples from randomly selected bottles were verified and the reference values were characterized using a highly precise isotope dilution gas chromatography-mass spectrometry (ID-GCMS) method that was recently developed by our laboratory. The purity of standard organochlorine chemicals was determined against certified reference materials to establish the accuracy of the ID-GCMS analysis. The concentrations (+/- expanded uncertainty) of hexachlorobenzene, alpha-hexachlorocyclohexane, beta-hexachlorocyclohexane and gamma-hexachlorocyclohexane in the reference material were 0.198 +/- 0.015, 0.450 +/- 0.022, 0.213 +/- 0.011 and 0.370 +/- 0.032 mg kg(-1), respectively. A portion (70 bottles) of the samples was also used in a proficiency testing (PT) scheme for assessing the testing capabilities of field laboratories. The consensus mean values of the PT obtained from the 70 participants were on the same order but deviated by -2.7 to -14.1% from those of the assigned reference values. Because of the wide spread of participants' data (relative standard deviation ranging from 44 to 56%), the PT results were not included in the calculation of the assigned values of the reference materials. The materials served as suitable reference materials to ascertain the quality control and validation processes for the

  17. U. S. programs on reference and advanced cladding/duct materials

    International Nuclear Information System (INIS)

    Bennett, J.W.; Holmes, J.J.; Laidler, J.J.

    1977-05-01

    Two coordinated national programs are presently in place in the United States for development of reference and advanced cladding and duct alloys for near-term and long-term LMFBR applications. A number of government, industrial and university laboratories are active participants in these two ERDA-sponsored programs. The programs are administered by ERDA through a task group organization, with each task group representing a particular technical activity and the membership of the task group drawn from among the laboratories with active involvement in that activity. Technical coordination of the two programs is provided by the Hanford Engineering Development Laboratory. The National Reference Cladding and Duct Program is charged with the responsibility for development of the required technology to permit full utilization of the reference material, 20 percent cold-worked Type 316 stainless steel, in early LMFBR core applications. The current schedule calls for full evaluation of FFTF-related design base data prior to full-power operation of FFTF in early 1980, followed by a confirmation in early 1983 of reference material performance capabilities for initial-core CRBRP applications. Comprehensive evaluation of reference material performance to commercial plant goal fluence levels will be complete by 1985. The National Advanced Alloy Development Program was instituted in 1974 with the objective to develop, by 1986, advanced cladding and duct materials compatible with advanced fuel systems having peak burnup capabilities up to 150 MWD/kg and doubling times of 15 years or less. Screening of a large number of potential alloys was completed in mid-1975, and there are presently 16 candidate alloys under active investigation

  18. Effect of endogenous reference genes on digital PCR assessment of genetically engineered canola events

    Directory of Open Access Journals (Sweden)

    Tigst Demeke

    2018-05-01

    Full Text Available Droplet digital PCR (ddPCR has been used for absolute quantification of genetically engineered (GE events. Absolute quantification of GE events by duplex ddPCR requires the use of appropriate primers and probes for target and reference gene sequences in order to accurately determine the amount of GE materials. Single copy reference genes are generally preferred for absolute quantification of GE events by ddPCR. Study has not been conducted on a comparison of reference genes for absolute quantification of GE canola events by ddPCR. The suitability of four endogenous reference sequences (HMG-I/Y, FatA(A, CruA and Ccf for absolute quantification of GE canola events by ddPCR was investigated. The effect of DNA extraction methods and DNA quality on the assessment of reference gene copy numbers was also investigated. ddPCR results were affected by the use of single vs. two copy reference genes. The single copy, FatA(A, reference gene was found to be stable and suitable for absolute quantification of GE canola events by ddPCR. For the copy numbers measured, the HMG-I/Y reference gene was less consistent than FatA(A reference gene. The expected ddPCR values were underestimated when CruA and Ccf (two copy endogenous Cruciferin sequences were used because of high number of copies. It is important to make an adjustment if two copy reference genes are used for ddPCR in order to obtain accurate results. On the other hand, real-time quantitative PCR results were not affected by the use of single vs. two copy reference genes. Keywords: Canola, Digital PCR, DNA extraction, GMO, Reference genes

  19. Diagnostic accuracy of direct ophthalmoscopy for detection of diabetic retinopathy using fundus photographs as a reference standard.

    Science.gov (United States)

    Ahsan, Shahid; Basit, Abdul; Ahmed, Kazi Rumana; Ali, Liaquat; Shaheen, Fariha; Ulhaque, Muhammad Saif; Fawwad, Asher

    2014-01-01

    To determine the diagnostic accuracy of direct ophthalmoscopy for the presence and severity of diabetic retinopathy (DR) using fundus photographs as a reference standard. Patients with type 2 diabetes attending the outpatient department (OPD) of a tertiary care diabetes center, from October 2009 to March 2010 were recruited in the study after obtaining signed informed consent. Patients with type 1 diabetes and gestational diabetes or having eye problems were excluded. After checking visual acuity, direct ophthalmoscopy of each eye was done by diabetologist, followed by photography of two fields of retina by fundus camera. DR was graded by a retinal specialist, according to International Diabetic Retinopathy Disease Severity Scale. According to severity, patients with DR were grouped into non-sight threatening diabetic retinopathy (NSTDR) and sight threatening diabetic retinopathy (STDR). Sensitivity and specificity of direct ophthalmoscopy for detection of any retinopathy, NSTDR and STDR was calculated. A total of 728 eyes were examined by direct ophthalmoscopy as well as fundus photography. Sensitivity (95% CI) of direct ophthalmoscopy for any retinopathy, NSTDR and STDR was found to be 55.67% (50.58-60.78), 37.63% (32.67-42.59) and 68.25% (63.48-73.02) respectively. Whereas, specificity of direct ophthalmoscopy was found to be 76.78% (72.45-81.11), 71.27% (CI: 66.63-75.91) and 90.0% (86.93-93.07) for any retinopathy, NSTDR and STDR respectively. The sensitivity and specificity of direct ophthalmoscopy performed by the diabetologist for the presence and severity of DR was lower compared to the recommended level of sensitivity and specificity of a screening test of DR. Copyright © 2014 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  20. Hearing the Sound in the Brain: Influences of Different EEG References

    Directory of Open Access Journals (Sweden)

    Dan Wu

    2018-03-01

    Full Text Available If the scalp potential signals, the electroencephalogram (EEG, are due to neural “singers” in the brain, how could we listen to them with less distortion? One crucial point is that the data recording on the scalp should be faithful and accurate, thus the choice of reference electrode is a vital factor determining the faithfulness of the data. In this study, music on the scalp derived from data in the brain using three different reference electrodes were compared, including approximate zero reference—reference electrode standardization technique (REST, average reference (AR, and linked mastoids reference (LM. The classic music pieces in waveform format were used as simulated sources inside a head model, and they were forward calculated to scalp as standard potential recordings, i.e., waveform format music from the brain with true zero reference. Then these scalp music was re-referenced into REST, AR, and LM based data, and compared with the original forward data (true zero reference. For real data, the EEG recorded in an orthodontic pain control experiment were utilized for music generation with the three references, and the scale free index (SFI of these music pieces were compared. The results showed that in the simulation for only one source, different references do not change the music/waveform; for two sources or more, REST provide the most faithful music/waveform to the original ones inside the brain, and the distortions caused by AR and LM were spatial locations of both source and scalp electrode dependent. The brainwave music from the real EEG data showed that REST and AR make the differences of SFI between two states more recognized and found the frontal is the main region that producing the music. In conclusion, REST can reconstruct the true signals approximately, and it can be used to help to listen to the true voice of the neural singers in the brain.

  1. STL pocket reference

    CERN Document Server

    Lischner, Ray

    2003-01-01

    The STL Pocket Reference describes the functions, classes, and templates in that part of the C++ standard library often referred to as the Standard Template Library (STL). The STL encompasses containers, iterators, algorithms, and function objects, which collectively represent one of the most important and widely used subsets of standard library functionality. The C++ standard library, even the subset known as the STL, is vast. It's next to impossible to work with the STL without some sort of reference at your side to remind you of template parameters, function invocations, return types--ind

  2. VBE reference framework

    NARCIS (Netherlands)

    Afsarmanesh, H.; Camarinha-Matos, L.M.; Ermilova, E.; Camarinha-Matos, L.M.; Afsarmanesh, H.; Ollus, M.

    2008-01-01

    Defining a comprehensive and generic "reference framework" for Virtual organizations Breeding Environments (VBEs), addressing all their features and characteristics, is challenging. While the definition and modeling of VBEs has become more formalized during the last five years, "reference models"

  3. Optimizing detectability

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    HPLC is useful for trace and ultratrace analyses of a variety of compounds. For most applications, HPLC is useful for determinations in the nanogram-to-microgram range; however, detection limits of a picogram or less have been demonstrated in certain cases. These determinations require state-of-the-art capability; several examples of such determinations are provided in this chapter. As mentioned before, to detect and/or analyze low quantities of a given analyte at submicrogram or ultratrace levels, it is necessary to optimize the whole separation system, including the quantity and type of sample, sample preparation, HPLC equipment, chromatographic conditions (including column), choice of detector, and quantitation techniques. A limited discussion is provided here for optimization based on theoretical considerations, chromatographic conditions, detector selection, and miscellaneous approaches to detectability optimization. 59 refs

  4. Noise detection in heart sound recordings.

    Science.gov (United States)

    Zia, Mohammad K; Griffel, Benjamin; Fridman, Vladimir; Saponieri, Cesare; Semmlow, John L

    2011-01-01

    Coronary artery disease (CAD) is the leading cause of death in the United States. Although progression of CAD can be controlled using drugs and diet, it is usually detected in advanced stages when invasive treatment is required. Current methods to detect CAD are invasive and/or costly, hence not suitable as a regular screening tool to detect CAD in early stages. Currently, we are developing a noninvasive and cost-effective system to detect CAD using the acoustic approach. This method identifies sounds generated by turbulent flow through partially narrowed coronary arteries to detect CAD. The limiting factor of this method is sensitivity to noises commonly encountered in the clinical setting. Because the CAD sounds are faint, these noises can easily obscure the CAD sounds and make detection impossible. In this paper, we propose a method to detect and eliminate noise encountered in the clinical setting using a reference channel. We show that our method is effective in detecting noise, which is essential to the success of the acoustic approach.

  5. Recent Advances in Molecular Technologies and Their Application in Pathogen Detection in Foods with Particular Reference to Yersinia

    Directory of Open Access Journals (Sweden)

    Jin Gui

    2011-01-01

    Full Text Available Yersinia enterocolitica is an important zoonotic pathogen that can cause yersiniosis in humans and animals. Food has been suggested to be the main source of yersiniosis. It is critical for the researchers to be able to detect Yersinia or any other foodborne pathogen with increased sensitivity and specificity, as well as in real-time, in the case of a foodborne disease outbreak. Conventional detection methods are known to be labor intensive, time consuming, or expensive. On the other hand, more sensitive molecular-based detection methods like next generation sequencing, microarray, and many others are capable of providing faster results. DNA testing is now possible on a single molecule, and high-throughput analysis allows multiple detection reactions to be performed at once, thus allowing a range of characteristics to be rapidly and simultaneously determined. Despite better detection efficiencies, results derived using molecular biology methods can be affected by the various food matrixes. With the improvements in sample preparation, data analysis, and testing procedures, molecular detection techniques will likely continue to simplify and increase the speed of detection while simultaneously improving the sensitivity and specificity for tracking pathogens in food matrices.

  6. Simultaneous determination of theobromine, (+)-catechin, caffeine, and (-)-epicatechin in standard reference material baking chocolate 2384, cocoa, cocoa beans, and cocoa butter.

    Science.gov (United States)

    Risner, Charles H

    2008-01-01

    A reverse-phase liquid chromatography analysis is used to access the quantity of theobromine, (+)-catechin, caffeine, and (-)-epicatechin in Standard Reference Material 2384 Baking Chocolate, cocoa, cocoa beans, and cocoa butter using water or a portion of the mobile phase as the extract. The procedure requires minimal sample preparation. Theobromine, (+)-catechin, caffeine, and (-)-epicatechin are detected by UV absorption at 273 nm after separation using a 0.3% acetic acid-methanol gradient (volume fractions) and quantified using external standards. The limit of detection for theobromine, (+)-catechin, caffeine, and (-)-epicatechin averages 0.08, 0.06, 0.06, and 0.06 microg/mL, respectively. The method when applied to Standard Reference Material 2384 Baking Chocolate; baking chocolate reference material yields results that compare to two different, separate procedures. Theobromine ranges from 26000 mg/kg in cocoa to 140 mg/kg in cocoa butter; (+)-catechin from 1800 mg/kg in cocoa to below detection limits of theobromine, 100.0 +/- 0.6 for (+)-catechin, 96.2 +/- 2.1 for caffeine, and 106.2 +/- 1.7 for (-)-epicatechin.

  7. Accuracy, precision, and lower detection limits (a deficit reduction approach)

    International Nuclear Information System (INIS)

    Bishop, C.T.

    1993-01-01

    The evaluation of the accuracy, precision and lower detection limits of the determination of trace radionuclides in environmental samples can become quite sophisticated and time consuming. This in turn could add significant cost to the analyses being performed. In the present method, a open-quotes deficit reduction approachclose quotes has been taken to keep costs low, but at the same time provide defensible data. In order to measure the accuracy of a particular method, reference samples are measured over the time period that the actual samples are being analyzed. Using a Lotus spreadsheet, data are compiled and an average accuracy is computed. If pairs of reference samples are analyzed, then precision can also be evaluated from the duplicate data sets. The standard deviation can be calculated if the reference concentrations of the duplicates are all in the same general range. Laboratory blanks are used to estimate the lower detection limits. The lower detection limit is calculated as 4.65 times the standard deviation of a set of blank determinations made over a given period of time. A Lotus spreadsheet is again used to compile data and LDLs over different periods of time can be compared

  8. Maximum Urine Flow Rate of Less than 15ml/Sec Increasing Risk of Urine Retention and Prostate Surgery among Patients with Alpha-1 Blockers: A 10-Year Follow Up Study.

    Directory of Open Access Journals (Sweden)

    Hsin-Ho Liu

    Full Text Available The aim of this study was to determine the subsequent risk of acute urine retention and prostate surgery in patients receiving alpha-1 blockers treatment and having a maximum urinary flow rate of less than 15ml/sec.We identified patients who were diagnosed with benign prostate hyperplasia (BPH and had a maximum uroflow rate of less than 15ml/sec between 1 January, 2002 to 31 December, 2011 from Taiwan's National Health Insurance Research Database into study group (n = 303. The control cohort included four BPH/LUTS patients without 5ARI used for each study group, randomly selected from the same dataset (n = 1,212. Each patient was monitored to identify those who subsequently developed prostate surgery and acute urine retention.Prostate surgery and acute urine retention are detected in 5.9% of control group and 8.3% of study group during 10-year follow up. Compared with the control group, there was increase in the risk of prostate surgery and acute urine retention in the study group (HR = 1.83, 95% CI: 1.16 to 2.91 after adjusting for age, comorbidities, geographic region and socioeconomic status.Maximum urine flow rate of less than 15ml/sec is a risk factor of urinary retention and subsequent prostate surgery in BPH patients receiving alpha-1 blocker therapy. This result can provide a reference for clinicians.

  9. Development and use of reference materials and quality control materials

    International Nuclear Information System (INIS)

    2003-04-01

    Current knowledge is summarized on correct use of commercially available certified reference materials (CRMs) and reference materials (RMs). Acknowledged are also the limitations and restrictions analysts have to face if they want to apply quality control. The concept of in-house RMs or quality control materials (QCMs) is advocated to supplement the use of CRMs for quality control purposes. On hand advice on how to select, prepare, characterize and use these QCMs is given from the experts' perspective. Several scenarios are described to make this concept widely applicable to: advanced laboratories with CRMs with validated analytical techniques available, laboratories with less experience and facilities, as well as cases were labile compounds and unstable matrices are involved. Each scenario considers different approaches to overcome the lack of appropriate CRMs and advise on the preparation of QCMs, which might fit the particular purpose

  10. Development and use of reference materials and quality control materials

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-04-01

    Current knowledge is summarized on correct use of commercially available certified reference materials (CRMs) and reference materials (RMs). Acknowledged are also the limitations and restrictions analysts have to face if they want to apply quality control. The concept of in-house RMs or quality control materials (QCMs) is advocated to supplement the use of CRMs for quality control purposes. On hand advice on how to select, prepare, characterize and use these QCMs is given from the experts' perspective. Several scenarios are described to make this concept widely applicable to: advanced laboratories with CRMs with validated analytical techniques available, laboratories with less experience and facilities, as well as cases were labile compounds and unstable matrices are involved. Each scenario considers different approaches to overcome the lack of appropriate CRMs and advise on the preparation of QCMs, which might fit the particular purpose.

  11. Feasibility of the development of reference materials for the detection of Ag nanoparticles in food: neat dispersions and spiked chicken meat

    NARCIS (Netherlands)

    Grombe, R.; Allmaier, G.; Charoud-Got, J.; Dudkiewicz, A.; Emteborg, H.; Hofmann, T.; Huusfeldt-Larsen, E.; Lehner, A.; Llinas, M.; Loeschner, K.; Molhave, K.; Peters, R.J.B.; Seghers, J.; Solans, C.; Kammer, van den F.; Wagner, S.; Weigel, S.; Linsinger, T.P.J.

    2015-01-01

    The feasibility of producing colloidal silver nanoparticle reference materials and silver nanoparticle spiked reference matrix materials was investigated. Two concentrations of PVP-coated silver nanoparticle dispersions were evaluated and used to spike chicken meat, with the aim of producing a set

  12. Crowdsourcing for error detection in cortical surface delineations.

    Science.gov (United States)

    Ganz, Melanie; Kondermann, Daniel; Andrulis, Jonas; Knudsen, Gitte Moos; Maier-Hein, Lena

    2017-01-01

    With the recent trend toward big data analysis, neuroimaging datasets have grown substantially in the past years. While larger datasets potentially offer important insights for medical research, one major bottleneck is the requirement for resources of medical experts needed to validate automatic processing results. To address this issue, the goal of this paper was to assess whether anonymous nonexperts from an online community can perform quality control of MR-based cortical surface delineations derived by an automatic algorithm. So-called knowledge workers from an online crowdsourcing platform were asked to annotate errors in automatic cortical surface delineations on 100 central, coronal slices of MR images. On average, annotations for 100 images were obtained in less than an hour. When using expert annotations as reference, the crowd on average achieves a sensitivity of 82 % and a precision of 42 %. Merging multiple annotations per image significantly improves the sensitivity of the crowd (up to 95 %), but leads to a decrease in precision (as low as 22 %). Our experiments show that the detection of errors in automatic cortical surface delineations generated by anonymous untrained workers is feasible. Future work will focus on increasing the sensitivity of our method further, such that the error detection tasks can be handled exclusively by the crowd and expert resources can be focused on error correction.

  13. User Preferences in Reference Services: Virtual Reference and Academic Libraries

    Science.gov (United States)

    Cummings, Joel; Cummings, Lara; Frederiksen, Linda

    2007-01-01

    This study examines the use of chat in an academic library's user population and where virtual reference services might fit within the spectrum of public services offered by academic libraries. Using questionnaires, this research demonstrates that many within the academic community are open to the idea of chat-based reference or using chat for…

  14. Who is referred for sedation for dentistry and why?

    Science.gov (United States)

    Boyle, C A; Newton, T; Milgrom, P

    2009-03-28

    To assess referrals to sedation, examining dental anxiety and background of patients, and compare these characteristics to those referred to a restorative dentistry clinic. Descriptive, cross sectional survey. Subjects were 100 consecutive new patients in sedation and special care and 50 new patients in restorative dentistry at Guy's and St Thomas NHS Foundation Trust. A questionnaire included demographics, self-reported oral health and dental attendance, and dental fear. Information from the patients records was taken: ASA classification, previous sedation or general anaesthesia, alcohol and tobacco use, and medications. The best predictors of referral were dental anxiety level and an irregular attendance. The most important fears were seeing, hearing and feeling the vibrations of the dental drill, and the perception of an accelerated heart rate. Other factors such as general, mental and dental health and alcohol use were related to referral but less important. Referral is consistent with the goal of the sedation clinic to see anxious patients. Referring general practitioners are able to identify these patients.

  15. Indicators of health system coverage and activity in Ireland during the economic crisis 2008-2014 - from 'more with less' to 'less with less'.

    LENUS (Irish Health Repository)

    Burke, Sara

    2014-09-01

    A new Irish government came to power in March 2011 with the most radical proposals for health system reform in the history of the state, including improving access to healthcare, free GP care for all by 2015 and the introduction of Universal Health Insurance after 2016. All this was to be achieved amidst the most severe economic crisis experienced by Ireland since the 1930s. The authors assess how well the system coped with a downsizing of resources by an analysis of coverage and health system activity indicators. These show a health system that managed \\'to do more with less\\' from 2008 to 2012. They also demonstrate a system that was \\'doing more with less\\' by transferring the cost of care onto people and by significant resource cuts. From 2013, the indicators show a system that has no choice but \\'to do less with less\\' with diminishing returns from crude cuts. This is evident in declining numbers with free care, of hospital cases and home care hours, alongside increased wait-times and expensive agency staffing. The results suggest a limited window of benefit from austerity beyond which cuts and rationing prevail which is costly, in both human and financial terms.

  16. Python essential reference

    CERN Document Server

    Beazley, David M

    2009-01-01

    Python Essential Reference is the definitive reference guide to the Python programming language — the one authoritative handbook that reliably untangles and explains both the core Python language and the most essential parts of the Python library. Designed for the professional programmer, the book is concise, to the point, and highly accessible. It also includes detailed information on the Python library and many advanced subjects that is not available in either the official Python documentation or any other single reference source. Thoroughly updated to reflect the significant new programming language features and library modules that have been introduced in Python 2.6 and Python 3, the fourth edition of Python Essential Reference is the definitive guide for programmers who need to modernize existing Python code or who are planning an eventual migration to Python 3. Programmers starting a new Python project will find detailed coverage of contemporary Python programming idioms.

  17. Breast Reference Set Application: Karen Abbott- University of Arkansas (2013) — EDRN Public Portal

    Science.gov (United States)

    We are evaluating whether detection of a tumor-specific N-linked glycosylation known as B 1,6 branched N-glycan present on the glycoprotein periostin in breast cancer will be useful as a new biomarker for the detection of breast cancer in patient plasma and serum. We have completed an initial study using samples with known inavasive ductal breast carcinoma diagnosis and the results look very promising. Therefore, we would like to proceed with our analysis of this potential biomarker for breast cancer diagnosis by analyzing the blinded samples in breast reference set 1.

  18. Assessing the accuracy of TDR-based water leak detection system

    Directory of Open Access Journals (Sweden)

    S.M. Fatemi Aghda

    2018-03-01

    Full Text Available The use of TDR system to detect leakage locations in underground pipes has been developed in recent years. In this system, a bi-wire is installed in parallel with the underground pipes and is considered as a TDR sensor. This approach greatly covers the limitations arisen with using the traditional method of acoustic leak positioning. TDR based leak detection method is relatively accurate when the TDR sensor is in contact with water in just one point. Researchers have been working to improve the accuracy of this method in recent years.In this study, the ability of TDR method was evaluated in terms of the appearance of multi leakage points simultaneously. For this purpose, several laboratory tests were conducted. In these tests in order to simulate leakage points, the TDR sensor was put in contact with water at some points, then the number and the dimension of the simulated leakage points were gradually increased. The results showed that with the increase in the number and dimension of the leakage points, the error rate of the TDR-based water leak detection system increases.The authors tried, according to the results obtained from the laboratory tests, to develop a method to improve the accuracy of the TDR-based leak detection systems. To do that, they defined a few reference points on the TDR sensor. These points were created via increasing the distance between two conductors of TDR sensor and were easily identifiable in the TDR waveform. The tests were repeated again using the TDR sensor having reference points. In order to calculate the exact distance of the leakage point, the authors developed an equation in accordance to the reference points. A comparison between the results obtained from both tests (with and without reference points showed that using the method and equation developed by the authors can significantly improve the accuracy of positioning the leakage points. Keywords: Multiple leakage points, TDR, Reference points

  19. Oblique-incidence reflectivity difference application for morphology detection.

    Science.gov (United States)

    Zhan, Honglei; Zhao, Kun; Lü, Huibin; Jin, Kuijuan; Yang, Guozhen; Chen, Xiaohong

    2017-10-20

    Analogous with scanning electron microscopy, we use an oblique-incidence reflectivity difference (OIRD) approach for morphology detection. By scanning the active carbon clusters in a one-dimensional way and the reservoir rocks in a two-dimensional way, the morphology of the samples' surface can be revealed in OIRD signal images. High OIRD signals of active carbon samples refer to the centralized distribution areas of carbon, and the fluctuations are caused by the uneven distribution of carbon pellets. OIRD intensity is proportional to the thickness of materials. In terms of rocks, the trough areas with smaller values refer to the low-lying fields. The areas with relatively large OIRD intensities correspond to the protuberance areas of rocks. Consequently, OIRD is a sensitive yet rapid measure of surface detection in material and petrogeology science.

  20. CSS Pocket Reference

    CERN Document Server

    Meyer, Eric

    2011-01-01

    When you're working with CSS and need a quick answer, CSS Pocket Reference delivers. This handy, concise book provides all of the essential information you need to implement CSS on the fly. Ideal for intermediate to advanced web designers and developers, the 4th edition is revised and updated for CSS3, the latest version of the Cascading Style Sheet specification. Along with a complete alphabetical reference to CSS3 selectors and properties, you'll also find a short introduction to the key concepts of CSS. Based on Cascading Style Sheets: The Definitive Guide, this reference is an easy-to-us

  1. Selection of suitable reference genes for RT-qPCR analyses in cyanobacteria.

    Directory of Open Access Journals (Sweden)

    Filipe Pinto

    Full Text Available Cyanobacteria are a group of photosynthetic prokaryotes that have a diverse morphology, minimal nutritional requirements and metabolic plasticity that has made them attractive organisms to use in biotechnological applications. The use of these organisms as cell factories requires the knowledge of their physiology and metabolism at a systems level. For the quantification of gene transcripts real-time quantitative polymerase chain reaction (RT-qPCR is the standard technique. However, to obtain reliable RT-qPCR results the use and validation of reference genes is mandatory. Towards this goal we have selected and analyzed twelve candidate reference genes from three morphologically distinct cyanobacteria grown under routinely used laboratory conditions. The six genes exhibiting less variation in each organism were evaluated in terms of their expression stability using geNorm, NormFinder and BestKeeper. In addition, the minimum number of reference genes required for normalization was determined. Based on the three algorithms, we provide a list of genes for cyanobacterial RT-qPCR data normalization. To our knowledge, this is the first work on the validation of reference genes for cyanobacteria constituting a valuable starting point for future works.

  2. Diagnostic reference activities for nuclear medicine in Australia and New Zealand

    International Nuclear Information System (INIS)

    Towson, J.E.; Smart, R.C.

    2001-01-01

    Nuclear medicine centres in Australia and New Zealand were surveyed in 1998 on behalf of the Australian and New Zealand Society of Nuclear Medicine (ANZSNM) and the Australasian Radiation Protection Society (ARPS) in order to establish diagnostic reference levels. A survey form was mailed to all centres, requesting information on the usual radiopharmaceutical activity administered to a standard adult patient and how the activity is calculated for children. The overall response rate was 89.5%. Data was obtained for 80 imaging procedures and 17 non-imaging tracer studies. For the 68 procedures for which data was available from 10 or more centres, the Most Common Activity and the Reference Activity were found from the mode and 75 th percentile of the distribution of activities. A follow-up survey of the 8 hospital centres specialising in pediatric nuclear medicine in Australia was conducted in 1999-2000. Data on the maximum and minimum administered activities (A max and A min ) was obtained for 43 pediatric imaging procedures. A max values were significantly less than the Reference Activities determined for adults. The median values of A max and A min are recommended as Pediatric Reference Activities. The effective dose from the Reference Activities was calculated for adults (male and female) and children. The survey results are available on the ANZSNM and ARPS web sites at http://www.anzsnm.org.au and http://www.arps.org.au. (author)

  3. Defining reference conditions for acidified waters using a modern analogue approach

    International Nuclear Information System (INIS)

    Simpson, Gavin L.; Shilland, Ewan M.; Winterbottom, Julie M.; Keay, Janey

    2005-01-01

    Analogue matching is a palaeolimnological technique that aims to find matches for fossil sediment samples from a set of modern surface sediment samples. Modern analogues were identified that closely matched the pre-disturbance conditions of eight of the UK Acid Waters Monitoring Network (AWMN) lakes using diatom- and cladoceran-based analogue matching. These analogue sites were assessed in terms of hydrochemistry, aquatic macrophytes and macro-invertebrates as to their suitability for defining wider hydrochemical and biological reference conditions for acidified sites within the AWMN. The analogues identified for individual AWMN sites show a close degree of similarity in terms of their hydrochemical characteristics, aquatic macrophytes and, to a lesser extent, macro-invertebrate fauna. The reference conditions of acidified AWMN sites are inferred to be less acidic than today and to support a wider range of acid-sensitive aquatic macrophyte and macro-invertebrate taxa than that recorded in the AWMN lakes over the period of monitoring since 1988. - The use of a palaeolimnological technique to identify modern ecological reference analogues for acidified lakes is demonstrated

  4. Effect of endogenous reference genes on digital PCR assessment of genetically engineered canola events.

    Science.gov (United States)

    Demeke, Tigst; Eng, Monika

    2018-05-01

    Droplet digital PCR (ddPCR) has been used for absolute quantification of genetically engineered (GE) events. Absolute quantification of GE events by duplex ddPCR requires the use of appropriate primers and probes for target and reference gene sequences in order to accurately determine the amount of GE materials. Single copy reference genes are generally preferred for absolute quantification of GE events by ddPCR. Study has not been conducted on a comparison of reference genes for absolute quantification of GE canola events by ddPCR. The suitability of four endogenous reference sequences ( HMG-I/Y , FatA(A), CruA and Ccf) for absolute quantification of GE canola events by ddPCR was investigated. The effect of DNA extraction methods and DNA quality on the assessment of reference gene copy numbers was also investigated. ddPCR results were affected by the use of single vs. two copy reference genes. The single copy, FatA(A), reference gene was found to be stable and suitable for absolute quantification of GE canola events by ddPCR. For the copy numbers measured, the HMG-I/Y reference gene was less consistent than FatA(A) reference gene. The expected ddPCR values were underestimated when CruA and Ccf (two copy endogenous Cruciferin sequences) were used because of high number of copies. It is important to make an adjustment if two copy reference genes are used for ddPCR in order to obtain accurate results. On the other hand, real-time quantitative PCR results were not affected by the use of single vs. two copy reference genes.

  5. Fault detection in finite frequency domain for Takagi-Sugeno fuzzy systems with sensor faults.

    Science.gov (United States)

    Li, Xiao-Jian; Yang, Guang-Hong

    2014-08-01

    This paper is concerned with the fault detection (FD) problem in finite frequency domain for continuous-time Takagi-Sugeno fuzzy systems with sensor faults. Some finite-frequency performance indices are initially introduced to measure the fault/reference input sensitivity and disturbance robustness. Based on these performance indices, an effective FD scheme is then presented such that the generated residual is designed to be sensitive to both fault and reference input for faulty cases, while robust against the reference input for fault-free case. As the additional reference input sensitivity for faulty cases is considered, it is shown that the proposed method improves the existing FD techniques and achieves a better FD performance. The theory is supported by simulation results related to the detection of sensor faults in a tunnel-diode circuit.

  6. Dual-Layer Density Estimation for Multiple Object Instance Detection

    Directory of Open Access Journals (Sweden)

    Qiang Zhang

    2016-01-01

    Full Text Available This paper introduces a dual-layer density estimation-based architecture for multiple object instance detection in robot inventory management applications. The approach consists of raw scale-invariant feature transform (SIFT feature matching and key point projection. The dominant scale ratio and a reference clustering threshold are estimated using the first layer of the density estimation. A cascade of filters is applied after feature template reconstruction and refined feature matching to eliminate false matches. Before the second layer of density estimation, the adaptive threshold is finalized by multiplying an empirical coefficient for the reference value. The coefficient is identified experimentally. Adaptive threshold-based grid voting is applied to find all candidate object instances. Error detection is eliminated using final geometric verification in accordance with Random Sample Consensus (RANSAC. The detection results of the proposed approach are evaluated on a self-built dataset collected in a supermarket. The results demonstrate that the approach provides high robustness and low latency for inventory management application.

  7. Sensitivity and Dynamic Range Considerations for Homodyne Detection Systems

    DEFF Research Database (Denmark)

    Jaggard, Dwight L.; King, Ray J

    1973-01-01

    The effects of modulation frequency, RF reference power, and external bias upon the sensitivity and dynamic range of microwave homodyne detection systems was measured for point contact diodes and low l/f noise Schottky and backward diodes. The measurements were made at 4.89 GHz using a signal...... to noise ratio of 3 dB and a detection system bandwidth of 10 Hz. Maximum sensitivities of -135, -150, and -145 dBm, and dynamic ranges of 92, 110, and 124 dB were measured for the point contact, Schottky, and backward diodes at modulation frequencies of 30, 30, and 3 kHz, respectively. It was found...... that the level of RF reference signal needed to obtain the maximum sensitivity was equal to or somewhat above the point where the diode changes from square law to linear detection. The results are significant in that previously reported homodyne sensitivities (not necessarily maximum) were on the order of -90...

  8. Roka Listeria detection method using transcription mediated amplification to detect Listeria species in select foods and surfaces. Performance Tested Method(SM) 011201.

    Science.gov (United States)

    Hua, Yang; Kaplan, Shannon; Reshatoff, Michael; Hu, Ernie; Zukowski, Alexis; Schweis, Franz; Gin, Cristal; Maroni, Brett; Becker, Michael; Wisniewski, Michele

    2012-01-01

    The Roka Listeria Detection Assay was compared to the reference culture methods for nine select foods and three select surfaces. The Roka method used Half-Fraser Broth for enrichment at 35 +/- 2 degrees C for 24-28 h. Comparison of Roka's method to reference methods requires an unpaired approach. Each method had a total of 545 samples inoculated with a Listeria strain. Each food and surface was inoculated with a different strain of Listeria at two different levels per method. For the dairy products (Brie cheese, whole milk, and ice cream), our method was compared to AOAC Official Method(SM) 993.12. For the ready-to-eat meats (deli chicken, cured ham, chicken salad, and hot dogs) and environmental surfaces (sealed concrete, stainless steel, and plastic), these samples were compared to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG) method MLG 8.07. Cold-smoked salmon and romaine lettuce were compared to the U.S. Food and Drug Administration/Bacteriological Analytical Manual, Chapter 10 (FDA/BAM) method. Roka's method had 358 positives out of 545 total inoculated samples compared to 332 positive for the reference methods. Overall the probability of detection analysis of the results showed better or equivalent performance compared to the reference methods.

  9. Conversion of ICRP male reference phantom to polygon-surface phantom

    International Nuclear Information System (INIS)

    Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi

    2013-01-01

    The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (<2 man-months), we were able to construct the polygon-surface phantom with the organ masses perfectly matching the ICRP reference values. The analysis of the calculated dose values also implies that the dose values are indeed not very sensitive to the detailed morphology of the organ models in the phantom

  10. Automated Detection of HONcode Website Conformity Compared to Manual Detection: An Evaluation.

    Science.gov (United States)

    Boyer, Célia; Dolamic, Ljiljana

    2015-06-02

    than 50% for contact details (100% precision, 69% recall), authority (85% precision, 52% recall), and reference (75% precision, 56% recall). The results also revealed issues for some criteria such as date. Changing the "document" definition (ie, using the sentence instead of whole document as a unit of classification) within the automated system resolved some but not all of them. Study results indicate concordance between automated and expert manual compliance detection for authority, privacy, reference, and contact details. Results also indicate that using the same general parameters for automated detection of each criterion produces suboptimal results. Future work to configure optimal system parameters for each HONcode principle would improve results. The potential utility of integrating automated detection of HONcode conformity into future search engines is also discussed.

  11. Identification of reference genes for quantitative expression analysis using large-scale RNA-seq data of Arabidopsis thaliana and model crop plants.

    Science.gov (United States)

    Kudo, Toru; Sasaki, Yohei; Terashima, Shin; Matsuda-Imai, Noriko; Takano, Tomoyuki; Saito, Misa; Kanno, Maasa; Ozaki, Soichi; Suwabe, Keita; Suzuki, Go; Watanabe, Masao; Matsuoka, Makoto; Takayama, Seiji; Yano, Kentaro

    2016-10-13

    In quantitative gene expression analysis, normalization using a reference gene as an internal control is frequently performed for appropriate interpretation of the results. Efforts have been devoted to exploring superior novel reference genes using microarray transcriptomic data and to evaluating commonly used reference genes by targeting analysis. However, because the number of specifically detectable genes is totally dependent on probe design in the microarray analysis, exploration using microarray data may miss some of the best choices for the reference genes. Recently emerging RNA sequencing (RNA-seq) provides an ideal resource for comprehensive exploration of reference genes since this method is capable of detecting all expressed genes, in principle including even unknown genes. We report the results of a comprehensive exploration of reference genes using public RNA-seq data from plants such as Arabidopsis thaliana (Arabidopsis), Glycine max (soybean), Solanum lycopersicum (tomato) and Oryza sativa (rice). To select reference genes suitable for the broadest experimental conditions possible, candidates were surveyed by the following four steps: (1) evaluation of the basal expression level of each gene in each experiment; (2) evaluation of the expression stability of each gene in each experiment; (3) evaluation of the expression stability of each gene across the experiments; and (4) selection of top-ranked genes, after ranking according to the number of experiments in which the gene was expressed stably. Employing this procedure, 13, 10, 12 and 21 top candidates for reference genes were proposed in Arabidopsis, soybean, tomato and rice, respectively. Microarray expression data confirmed that the expression of the proposed reference genes under broad experimental conditions was more stable than that of commonly used reference genes. These novel reference genes will be useful for analyzing gene expression profiles across experiments carried out under various

  12. A preliminary comparative study on the content of cesium, thorium and uranium in IAEA standard reference material

    International Nuclear Information System (INIS)

    Zhang Jing; Liu Husheng; Wang Xiaoyan; Wang Naifen

    2000-01-01

    This paper presents the detection of Cs, Th and U in 6 standard reference materials provided by IAEA, using the ICP-MS method. The bismuth (Bi) was selected as internal standard element for the range compensation of matrix inhibitory effect and flow of the sensibility. The detection limit of the 3 elements was limited in the range of 0.0006∼2ng/ml, 0.4∼0.5g sample was taken and digested by acid, and detected directly by ICP-MS. The recovery of standard addition was 82.1∼100.1%

  13. Endogenizing Prospect Theory's Reference Point

    OpenAIRE

    Ulrich Schmidt; Horst Zank

    2010-01-01

    In previous models of (cumulative) prospect theory reference-dependence of preferences is imposed beforehand and the location of the reference point is exogenously determined. This note provides a foundation of prospect theory, where reference-dependence is derived from preference conditions and a unique reference point arises endogenously.

  14. Toward multimodal signal detection of adverse drug reactions.

    Science.gov (United States)

    Harpaz, Rave; DuMouchel, William; Schuemie, Martijn; Bodenreider, Olivier; Friedman, Carol; Horvitz, Eric; Ripple, Anna; Sorbello, Alfred; White, Ryen W; Winnenburg, Rainer; Shah, Nigam H

    2017-12-01

    Improving mechanisms to detect adverse drug reactions (ADRs) is key to strengthening post-marketing drug safety surveillance. Signal detection is presently unimodal, relying on a single information source. Multimodal signal detection is based on jointly analyzing multiple information sources. Building on, and expanding the work done in prior studies, the aim of the article is to further research on multimodal signal detection, explore its potential benefits, and propose methods for its construction and evaluation. Four data sources are investigated; FDA's adverse event reporting system, insurance claims, the MEDLINE citation database, and the logs of major Web search engines. Published methods are used to generate and combine signals from each data source. Two distinct reference benchmarks corresponding to well-established and recently labeled ADRs respectively are used to evaluate the performance of multimodal signal detection in terms of area under the ROC curve (AUC) and lead-time-to-detection, with the latter relative to labeling revision dates. Limited to our reference benchmarks, multimodal signal detection provides AUC improvements ranging from 0.04 to 0.09 based on a widely used evaluation benchmark, and a comparative added lead-time of 7-22 months relative to labeling revision dates from a time-indexed benchmark. The results support the notion that utilizing and jointly analyzing multiple data sources may lead to improved signal detection. Given certain data and benchmark limitations, the early stage of development, and the complexity of ADRs, it is currently not possible to make definitive statements about the ultimate utility of the concept. Continued development of multimodal signal detection requires a deeper understanding the data sources used, additional benchmarks, and further research on methods to generate and synthesize signals. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Aggression in children with autism spectrum disorders and a clinic-referred comparison group

    Science.gov (United States)

    Farmer, Cristan; Butter, Eric; Mazurek, Micah O.; Cowan, Charles; Lainhart, Janet; Cook, Edwin H.; DeWitt, Mary Beth; Aman, Michael

    2015-01-01

    A gap exists in the literature regarding aggression in autism spectrum disorders (ASD) and how this behavior compares to other groups. In this multisite study, the Children’s Scale for Hostility and Aggression: Reactive/Proactive (C-SHARP) and the Aggression subscale of the Child Behavior Checklist (CBCL) were rated for 414 children with ASD (Autistic Disorder, 69%; PDD-NOS, 24%; Asperger’s Disorder, 7%) and 243 clinic-referred children without ASD, aged 1-21 years (mean age about 7). Participants were not selected for aggressive behavior. Relative to the comparison group, children with ASD were reported to have less aggression and were more likely to be rated as reactive rather than proactive. Among all subjects, sex was not associated with aggression; higher IQ/adaptive behavior and older age were associated with more sophisticated types of aggression while lower scores on IQ, adaptive behavior, and communication measures were associated with more physical aggression. The interaction between demographic variables and diagnosis was significant only for age: younger but not older children with ASD showed less aggression than clinic-referred controls. PMID:24497627

  16. Detection of genomic instability in hypospadias patients by random ...

    African Journals Online (AJOL)

    DIRECTOR

    2011-05-16

    May 16, 2011 ... organism including bacteria (Sahoo et al., 2010), fungi. (Motlagh and Anvari ... technique that detects genomic alteration correlated with human tumor is .... chromosomal instability among hypospadias patients. REFERENCES.

  17. The citation with reference and the citation as a reference

    Directory of Open Access Journals (Sweden)

    Rafael Antonio Cunha Perrone

    2011-12-01

    Full Text Available O ensaio objetiva estabelecer paralelos entre a citação acadêmica e a citação utilizada como referência, para a produção das obras ou projetos de arquitetura. O artigo discute o uso de figuras paradigmáticas ou significativas, transladadas ou amalgamadas nas obras de arquitetura, a partir do entendimento da citação como dado argumentativo e qualitativo. Investiga algumas de suas assimetrias e congruências em sua utilização na linguagem escrita, como transcrição direta ou como fonte interpretativa, reelaborada e incorporada como argumento em outro texto. Pondera que no ensinar, estudar e fazer arquitetura é preciso saber citar com referência, para poder citar como referência.

  18. CFAR Detection from Noncoherent Radar Echoes Using Bayesian Theory

    Directory of Open Access Journals (Sweden)

    Wataru Suganuma

    2010-01-01

    Full Text Available We propose a new constant false alarm rate (CFAR detection method from noncoherent radar echoes, considering heterogeneous sea clutter. It applies the Bayesian theory for adaptive estimation of the local clutter statistical distribution in the cell under test. The detection technique can be readily implemented in existing noncoherent marine radar systems, which makes it particularly attractive for economical CFAR detection systems. Monte Carlo simulations were used to investigate the detection performance and demonstrated that the proposed technique provides a higher probability of detection than conventional techniques, such as cell averaging CFAR (CA-CFAR, especially with a small number of reference cells.

  19. CFAR Detection from Noncoherent Radar Echoes Using Bayesian Theory

    Directory of Open Access Journals (Sweden)

    Yamaguchi Hiroyuki

    2010-01-01

    Full Text Available Abstract We propose a new constant false alarm rate (CFAR detection method from noncoherent radar echoes, considering heterogeneous sea clutter. It applies the Bayesian theory for adaptive estimation of the local clutter statistical distribution in the cell under test. The detection technique can be readily implemented in existing noncoherent marine radar systems, which makes it particularly attractive for economical CFAR detection systems. Monte Carlo simulations were used to investigate the detection performance and demonstrated that the proposed technique provides a higher probability of detection than conventional techniques, such as cell averaging CFAR (CA-CFAR, especially with a small number of reference cells.

  20. Marketing Reference Services.

    Science.gov (United States)

    Norman, O. Gene

    1995-01-01

    Relates the marketing concept to library reference services. Highlights include a review of the literature and an overview of marketing, including research, the marketing mix, strategic plan, marketing plan, and marketing audit. Marketing principles are applied to reference services through the marketing mix elements of product, price, place, and…

  1. Diffusion-weighted and T2-weighted MR imaging for colorectal liver metastases detection in a rat model at 7 T: a comparative study using histological examination as reference

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Mathilde; Ronot, Maxime; Vilgrain, Valerie; Beers, Bernard E. van [University Paris Diderot, Sorbonne Paris Cite, INSERM UMR 773, University Hospitals Paris Nord Val de Seine, Beaujon, Assistance Publique- Hopitaux de Paris, Laboratory of Physiological and Molecular Imaging of the Abdomen (IPMA) and Department of Radiology, Clichy Cedex (France); Maggiori, Leon; Panis, Yves [University Paris Diderot, Sorbonne Paris Cite, INSERM UMR 773, University Hospitals Paris Nord Val de Seine, Beaujon, Assistance Publique-Hopitaux de Paris, Department of Colorectal Surgery, Clichy (France); Paradis, Valerie [University Paris Diderot, Sorbonne Paris Cite, INSERM UMR 773, University Hospitals Paris Nord Val de Seine, Beaujon, Assistance Publique-Hopitaux de Paris, Department of Pathology, Clichy (France)

    2013-08-15

    To compare diffusion-weighted (DW) and T2-weighted MR imaging in detecting colorectal liver metastases in a rat model, using histological examination as a reference method. Eighteen rats had four liver injections of colon cancer cells. MR examinations at 7 T included FSE-T2-weighted imaging and SE-DW MR imaging (b = 0, 20 and 150 s/mm{sup 2}) and were analysed by two independent readers. Histological examination was performed on 0.4-mm slices. McNemar's test was used to compare the sensitivities and the Wilcoxon matched pairs test to compare the average number of false-positives per rat. One hundred and sixty-six liver metastases were identified on histological examination. The sensitivity in detecting liver metastases was significantly higher on DW MR than on T2-weighted images (99/166 (60 %) (reader 1) and 92/166 (55 %) (reader 2) versus 77/166 (46 %), P {<=} 0.001), without an increase in false-positives per rat (P = 0.773/P = 0.850). After stratification according to metastasis diameter, DW MR imaging had a significantly higher sensitivity than T2-weighted imaging only for metastases with a diameter (0.6-1.2 mm) similar to that of the spatial resolution of MR imaging in the current study. This MR study with histological correlations shows the higher sensitivity of DW relative to T2-weighted imaging at 7 T for detecting liver metastases, especially small ones. (orig.)

  2. About Nano-JASMINE Satellite System and Project Status

    Science.gov (United States)

    Sako, Nobutada

    Intelligent Space Systems Laboratory, The University of Tokyo (ISSL) and National Astronomical Observatory of Japan (NAO) have been developing a small infrared astrometry satellite named “Nano-JASMINE”. The satellite size is about 50cm cubic and 20kg, which plays a pre-cursor role of JASMINE Project which is programmed by NAO and JAXA. In addition, since there has been only one astrometry satellite HIPPARCOS by ESA in the past, Nano-JASMINE is also expected to achieve certain scientific results in the field of astrometry. In this project, ISSL aims to develop new advanced small satellite bus system whose performance is comparable to that of 100-500kg sized satellites, including attitude stability of 1 arc-second and thermal stability of the mission subsystem of 1 mK. This paper overviews the Nano-JASMINE bus system with emphasis on attitude and thermal control systems.

  3. Symptoms, diagnoses, and sporting consequences among athletes referred to a Danish sports cardiology clinic

    DEFF Research Database (Denmark)

    Kaiser-Nielsen, L V; Tischer, S G; Prescott, E B

    2017-01-01

    investigated the prevalence of cardiac symptoms and diagnoses among 201 athletes referred for cardiac evaluation at a Sports Cardiology Clinic in Denmark. To our knowledge, this is the first systematic study of athletes referred for suspected cardiac disease. The athletes were all well-trained recreational...... to elite athletes who participated in various sports with different training loads and a wide age span (13-66 years). All patients were referred by physicians, primarily their general practitioner (38%), and palpitations were the most common cardiac symptom (40%). Cardiac symptoms had a sensitivity of 86......% in detecting cardiac disease and a specificity of 13%. Cardiac disease was diagnosed in 44% of the patients, and atrial fibrillation was the most prevalent diagnosis (7.5%). Cardiac diseases with therapeutic- or sports-related consequences for the patients were diagnosed in 28% of the population, but only 1...

  4. Evaluation of a single-item screening question to detect limited health literacy in peritoneal dialysis patients.

    Science.gov (United States)

    Jain, Deepika; Sheth, Heena; Bender, Filitsa H; Weisbord, Steven D; Green, Jamie A

    2014-01-01

    Studies have shown that a single-item question might be useful in identifying patients with limited health literacy. However, the utility of the approach has not been studied in patients receiving maintenance peritoneal dialysis (PD). We assessed health literacy in a cohort of 31 PD patients by administering the Rapid Estimate of Adult Literacy in Medicine (REALM) and a single-item health literacy (SHL) screening question "How confident are you filling out medical forms by yourself?" (Extremely, Quite a bit, Somewhat, A little bit, or Not at all). To determine the accuracy of the single-item question for detecting limited health literacy, we performed sensitivity and specificity analyses of the SHL and plotted the area under the receiver operating characteristic (AUROC) curve using the REALM as a reference standard. Using a cut-off of "Somewhat" or less confident, the sensitivity of the SHL for detecting limited health literacy was 80%, and the specificity was 88%. The positive likelihood ratio was 6.9. The SHL had an AUROC of 0.79 (95% confidence interval: 0.52 to 1.00). Our results show that the SHL could be effective in detecting limited health literacy in PD patients.

  5. LINQ Pocket Reference

    CERN Document Server

    Albahari, Joseph

    2008-01-01

    Ready to take advantage of LINQ with C# 3.0? This guide has the detail you need to grasp Microsoft's new querying technology, and concise explanations to help you learn it quickly. And once you begin to apply LINQ, the book serves as an on-the-job reference when you need immediate reminders. All the examples in the LINQ Pocket Reference are preloaded into LINQPad, the highly praised utility that lets you work with LINQ interactively. Created by the authors and free to download, LINQPad will not only help you learn LINQ, it will have you thinking in LINQ. This reference explains: LINQ's ke

  6. Astrometry of the Red Supergiant Star VY Canis Majoris with VERA

    Science.gov (United States)

    Choi, Y. K.; Hirota, T.; Honma, M.; Kobayashi, H.

    2009-08-01

    We present observational results on the red supergiant VY Canis Majoris with VERA. We have observed 22 GHz H_2O masers and 43 GHz SiO masers (v=1 and 2 J=1-0) around VY CMa for 13 months. We successfully detected a parallax of 0.87 ± 0.08 mas, corresponding to 1.15 +0.10 -0.09 kpc of distance using H_2O masers. As results of phase--referencing analyses, we have measured absolute positions for both the H_2O masers and SiO masers. The proper motions of the H_2O masers show the tendency of expansion.

  7. A new birthweight reference in Guangzhou, southern China, and its comparison with the global reference.

    Science.gov (United States)

    He, Jian-Rong; Xia, Hui-Min; Liu, Yu; Xia, Xiao-Yan; Mo, Wei-Jian; Wang, Ping; Cheng, Kar Keung; Leung, Gabriel M; Feng, Qiong; Schooling, C Mary; Qiu, Xiu

    2014-12-01

    To formulate a new birthweight reference for different gestational ages in Guangzhou, southern China, and compare it with the currently used reference in China and the global reference. All singleton live births of more than 26 weeks' gestational age recorded in the Guangzhou Perinatal Health Care and Delivery Surveillance System for the years 2009, 2010 and 2011 (n=510 837) were retrospectively included in the study. In addition, the study sample was supplemented by all singleton live births (n=3538) at gestational ages 26-33 weeks from 2007 and 2008. We used Gaussian mixture models and robust regression to exclude outliers of birth weight and then applied Generalized Additive Models for Location, Scale, and Shape (GAMLSS) to generate smoothed percentile curves separately for gender and parity. Of infants defined as small for gestational age (SGA) in the new reference, 15.3-47.7% (depending on gestational age) were considered appropriate for gestational age (AGA) by the currently used reference of China. Of the infants defined as SGA by the new reference, 9.2% with gestational ages 34-36 weeks and 14.3% with 37-41 weeks were considered AGA by the global reference. At the 50th centile line, the new reference curve was similar to that of the global reference for gestational ages 26-33 weeks and above the global reference for 34-40 weeks. The new birthweight reference based on birthweight data for neonates in Guangzhou, China, differs from the reference currently used in China and the global reference, and appears to be more relevant to the local population. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  8. The Mosaic Ancestry of the Drosophila Genetic Reference Panel and the D. melanogaster Reference Genome Reveals a Network of Epistatic Fitness Interactions.

    Science.gov (United States)

    Pool, John E

    2015-12-01

    North American populations of Drosophila melanogaster derive from both European and African source populations, but despite their importance for genetic research, patterns of ancestry along their genomes are largely undocumented. Here, I infer geographic ancestry along genomes of the Drosophila Genetic Reference Panel (DGRP) and the D. melanogaster reference genome, which may have implications for reference alignment, association mapping, and population genomic studies in Drosophila. Overall, the proportion of African ancestry was estimated to be 20% for the DGRP and 9% for the reference genome. Combining my estimate of admixture timing with historical records, I provide the first estimate of natural generation time for this species (approximately 15 generations per year). Ancestry levels were found to vary strikingly across the genome, with less African introgression on the X chromosome, in regions of high recombination, and at genes involved in specific processes (e.g., circadian rhythm). An important role for natural selection during the admixture process was further supported by evidence that many unlinked pairs of loci showed a deficiency of Africa-Europe allele combinations between them. Numerous epistatic fitness interactions may therefore exist between African and European genotypes, leading to ongoing selection against incompatible variants. By focusing on hubs in this network of fitness interactions, I identified a set of interacting loci that include genes with roles in sensation and neuropeptide/hormone reception. These findings suggest that admixed D. melanogaster samples could become an important study system for the genetics of early-stage isolation between populations. © The Author 2015. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.

  9. Dissemination of optical-comb-based ultra-broadband frequency reference through a fiber network.

    Science.gov (United States)

    Nagano, Shigeo; Kumagai, Motohiro; Li, Ying; Ido, Tetsuya; Ishii, Shoken; Mizutani, Kohei; Aoki, Makoto; Otsuka, Ryohei; Hanado, Yuko

    2016-08-22

    We disseminated an ultra-broadband optical frequency reference based on a femtosecond (fs)-laser optical comb through a kilometer-scale fiber link. Its spectrum ranged from 1160 nm to 2180 nm without additional fs-laser combs at the end of the link. By employing a fiber-induced phase noise cancellation technique, the linewidth and fractional frequency instability attained for all disseminated comb modes were of order 1 Hz and 10-18 in a 5000 s averaging time. The ultra-broad optical frequency reference, for which absolute frequency is traceable to Japan Standard Time, was applied in the frequency stabilization of an injection-seeded Q-switched 2051 nm pulse laser for a coherent light detection and ranging LIDAR system.

  10. Flaw detection device for plasma facing wall in thermonuclear device

    International Nuclear Information System (INIS)

    Doi, Akira.

    1996-01-01

    The present invention concerns plasma facing walls of a thermonuclear device and provides a device for detecting a thickness of amour tiles accurately and efficiently with no manual operation. Namely, the position of the plasma facing surface of the amour tile is measured using a structure to which the amour tiles are to be disposed as a reference. Also in a case of disposing new armor tiles, the position of the plasma facing surface of the armor tiles is measured to thereby measure the wearing amount of the amour tiles based on the difference between the reference and the measured value. If a measuring means capable of measuring a plurality of amour tiles at once is used efficiency of the measurement and the detection can be enhanced. Several ten thousands of amour tiles are disposed to the plasma facing wall in a large scaled thermonuclear device, and a plenty of time was required for the detection. However, the present invention can improve the accuracy for the measurement and detection and provide time and labors-saving. (I.S.)

  11. Reference Japanese man

    International Nuclear Information System (INIS)

    Tanaka, Giichiro

    1985-01-01

    To make real and accurate dose assessment method so far, it is necessitated to provide ''Reference Japanese Man'' based on anotomical, physiological and biochemical data of Japanese people instead of the Reference Man presented in ICRP Publications 23 and 30. This review describes present status of researched for the purpose of establishing of Reference Japanese Man. The Reference Japanese Man is defined as a male or female adult who lives in Japan with a Japanese life-style and food custom. His stature and body weight, and the other data was decided as mean values of male or female people of Japan. As for food custom, Japanese people take significantly smaller amount of meat and milk products than Western people, while larger intake amount of cereals and marine products such as fish or seaweeds. Weight of organs is a principal factor for internal dose assessment and mean values for living Japanese adult has been investigated and the value employable for dose assessment for organs and tissues are shown. To employ these values of Reference Japanese Man, it should be taken into account of age. Metabolic parameters should also be considered. Iodine metabolism in Japanese is quite different from that of Western people. The above-mentioned data are now tentatively employing in modification of table of MIRD method and others. (Takagi, S.)

  12. Digital PCR for detection of citrus pathogens

    Science.gov (United States)

    Citrus trees are often infected with multiple pathogens of economic importance, especially those with insect or mite vectors. Real-time/quantitative PCR (qPCR) has been used for high-throughput detection and relative quantification of pathogens; however, target reference or standards are required. I...

  13. Genetic variability of hull-less barley accessions based on molecular and quantitative data

    Directory of Open Access Journals (Sweden)

    Ricardo Meneses Sayd

    2015-02-01

    Full Text Available The objective of this work was to characterize and quantify the genetic, molecular, and agronomic variability of hull-less barley genotypes, for the selection of parents and identification of genotypes adapted to the irrigated production system in the Brazilian Cerrado. Eighteen hull-less barley accessions were evaluated, and three covered barley accessions served as reference. The characterization was based on 157 RAPD molecular markers and ten agronomic traits. Genetic distance matrices were obtained based on molecular markers and quantitative traits. Graphic grouping and dispersion analyses were performed. Genetic, molecular, and agronomic variability was high among genotypes. Ethiopian accessions were genetically more similar, and the Brazilian ones were genetically more distant. For agronomic traits, two more consistent groupings were obtained, one with the most two-rowed materials, and the other with six-rowed materials. The more diverging materials were the two-rowed CI 13453, CN Cerrado 5, CN Cerrado 1, and CN Cerrado 2. The PI 356466, CN Cerrado 1, PI 370799, and CI 13453 genotypes show agronomic traits of interest and, as genetically different genotypes, they are indicated for crossing, in breeding programs.

  14. Evaluation of MC and A detection time

    International Nuclear Information System (INIS)

    Smith, B.W.; Thomas, N.M.

    1984-07-01

    The US Nuclear Regulatory Commission has proposed reform of the material control and accounting (MC and A) requirements for facilities authorized to possess and use formula quantities of strategic special nuclear material (SSNM). The purpose of the reform is to strengthen MC and A capabilities by requiring more timely detection of possible SSNM losses and by providing for more rapid and conclusive resolution of discrepancies. This study was conducted to identify the advantages and disadvantages of detection time intervals ranging from one day to two weeks. Material loss tests based on existing process monitoring data are used to compare the detection sensitiviy, alarm frequency, resolution capability and effort to collect and process data for the stipulated range of detection times. 15 references, 4 figures, 12 tables

  15. Reference in human and non-human primate communication: What does it take to refer?

    Science.gov (United States)

    Sievers, Christine; Gruber, Thibaud

    2016-07-01

    The concept of functional reference has been used to isolate potentially referential vocal signals in animal communication. However, its relatedness to the phenomenon of reference in human language has recently been brought into question. While some researchers have suggested abandoning the concept of functional reference altogether, others advocate a revision of its definition to include contextual cues that play a role in signal production and perception. Empirical and theoretical work on functional reference has also put much emphasis on how the receiver understands the referential signal. However, reference, as defined in the linguistic literature, is an action of the producer, and therefore, any definition describing reference in non-human animals must also focus on the producer. To successfully determine whether a signal is used to refer, we suggest an approach from the field of pragmatics, taking a closer look at specific situations of signal production, specifically at the factors that influence the production of a signal by an individual. We define the concept of signaller's reference to identify intentional acts of reference produced by a signaller independently of the communicative modality, and illustrate it with a case study of the hoo vocalizations produced by wild chimpanzees during travel. This novel framework introduces an intentional approach to referentiality. It may therefore permit a closer comparison of human and non-human animal referential behaviour and underlying cognitive processes, allowing us to identify what may have emerged solely in the human lineage.

  16. Reference class forecasting

    DEFF Research Database (Denmark)

    Flyvbjerg, Bent

    optimisme og misinformation. RCF bygger på teorier, som vandt Daniel Kahneman Nobelprisen i økonomi i 2002. RCF estimerer budgettet for et givet projekt på grundlag af de faktiske udfald for budgetterne i en reference-klasse af projekter. RCF udføres i tre trin: 1. Identifikation af en relevant reference...

  17. Digital quadrature phase detection

    Science.gov (United States)

    Smith, J.A.; Johnson, J.A.

    1992-05-26

    A system for detecting the phase of a frequency or phase modulated signal that includes digital quadrature sampling of the frequency or phase modulated signal at two times that are one quarter of a cycle of a reference signal apart, determination of the arctangent of the ratio of a first sampling of the frequency or phase modulated signal to the second sampling of the frequency or phase modulated signal, and a determination of quadrant in which the phase determination is increased by 2[pi] when the quadrant changes from the first quadrant to the fourth quadrant and decreased by 2[pi] when the quadrant changes from the fourth quadrant to the first quadrant whereby the absolute phase of the frequency or phase modulated signal can be determined using an arbitrary reference convention. 6 figs.

  18. Corrosion behavior of duplex and reference cladding in NPP Grohnde

    International Nuclear Information System (INIS)

    Besch, O.A.; Yagnik, S.K.; Eucken, C.M.; Bradley, E.R.

    1996-01-01

    The Nuclear Fuel Industry Research (NFIR) Group undertook a lead test assembly (LTA) program in NPP Grohnde PWR in Germany to assess the corrosion performance of duplex and reference cladding. Two identical 16 by 16 LTAs, each containing 32 peripheral test rods, completed four reactor cycles, reaching a peak rod burnup of 46 MWd/kgU. The results from poolside examinations performed at the end of each cycle, together with power histories and coolant chemistry, are reported. Five different cladding materials were characterized during fabrication. The corrosion performance of the cladding materials was tracked in long-term tests in high-pressure, high-temperature autoclaves. The relative ranking of corrosion behavior in such tests corresponded well with the in-reactor corrosion performance. The extent and distribution of hydriding in duplex and reference specimens during the autoclave testing has been characterized. The in-reactor corrosion data indicate that the low-tin Zircaloy-4 reference cladding, R2, had an improved corrosion resistance compared to high-tin Zircaloy-4 reference cladding, R1. Two types of duplex cladding, D1 (Zr-2.5% Nb) and D2 (Zr-0.4% Fe-0.5% Sn), showed an even further improvement in corrosion resistance compared to R2 cladding. The third duplex cladding, D3 (Zr-4 + 1.0% Nb), had significantly less corrosion resistance, which was inferior to R1. The in-reactor and out-reactor corrosion performances have been ranked

  19. Android quick APIs reference

    CERN Document Server

    Cinar, Onur

    2015-01-01

    The Android Quick APIs Reference is a condensed code and APIs reference for the new Google Android 5.0 SDK. It presents the essential Android APIs in a well-organized format that can be used as a handy reference. You won't find any technical jargon, bloated samples, drawn out history lessons, or witty stories in this book. What you will find is a software development kit and APIs reference that is concise, to the point and highly accessible. The book is packed with useful information and is a must-have for any mobile or Android app developer or programmer. In the Android Quick APIs Refe

  20. Quantum mechanics in noninertial reference frames: Violations of the nonrelativistic equivalence principle

    International Nuclear Information System (INIS)

    Klink, W.H.; Wickramasekara, S.

    2014-01-01

    In previous work we have developed a formulation of quantum mechanics in non-inertial reference frames. This formulation is grounded in a class of unitary cocycle representations of what we have called the Galilean line group, the generalization of the Galilei group that includes transformations amongst non-inertial reference frames. These representations show that in quantum mechanics, just as is the case in classical mechanics, the transformations to accelerating reference frames give rise to fictitious forces. A special feature of these previously constructed representations is that they all respect the non-relativistic equivalence principle, wherein the fictitious forces associated with linear acceleration can equivalently be described by gravitational forces. In this paper we exhibit a large class of cocycle representations of the Galilean line group that violate the equivalence principle. Nevertheless the classical mechanics analogue of these cocycle representations all respect the equivalence principle. -- Highlights: •A formulation of Galilean quantum mechanics in non-inertial reference frames is given. •The key concept is the Galilean line group, an infinite dimensional group. •A large class of general cocycle representations of the Galilean line group is constructed. •These representations show violations of the equivalence principle at the quantum level. •At the classical limit, no violations of the equivalence principle are detected