WorldWideScience

Sample records for reference standard results

  1. Standard Reference Tables -

    Data.gov (United States)

    Department of Transportation — The Standard Reference Tables (SRT) provide consistent reference data for the various applications that support Flight Standards Service (AFS) business processes and...

  2. Ozone Standard Reference Photometer

    Data.gov (United States)

    Federal Laboratory Consortium — The Standard Reference Photometer (SRP) Program began in the early 1980s as collaboration between NIST and the U.S. Environmental Protection Agency (EPA) to design,...

  3. Standardization of glycohemoglobin results and reference values in whole blood studied in 103 laboratories using 20 methods.

    Science.gov (United States)

    Weykamp, C W; Penders, T J; Miedema, K; Muskiet, F A; van der Slik, W

    1995-01-01

    We investigated the effect of calibration with lyophilized calibrators on whole-blood glycohemoglobin (glyHb) results. One hundred three laboratories, using 20 different methods, determined glyHb in two lyophilized calibrators and two whole-blood samples. For whole-blood samples with low (5%) and high (9%) glyHb percentages, respectively, calibration decreased overall interlaboratory variation (CV) from 16% to 9% and from 11% to 6% and decreased intermethod variation from 14% to 6% and from 12% to 5%. Forty-seven laboratories, using 14 different methods, determined mean glyHb percentages in self-selected groups of 10 nondiabetic volunteers each. With calibration their overall mean (2SD) was 5.0% (0.5%), very close to the 5.0% (0.3%) derived from the reference method used in the Diabetes Control and Complications Trial. In both experiments the Abbott IMx and Vision showed deviating results. We conclude that, irrespective of the analytical method used, calibration enables standardization of glyHb results, reference values, and interpretation criteria.

  4. MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Maijers, M.C.; Ritt, M.J.P.F. [VU University Medical Centre, Department of Plastic, Reconstructive and Hand Surgery, De Boelelaan 1117, PO Box 7057, Amsterdam (Netherlands); Niessen, F.B. [VU University Medical Centre, Department of Plastic, Reconstructive and Hand Surgery, De Boelelaan 1117, PO Box 7057, Amsterdam (Netherlands); Jan van Goyen Clinic, Department of Plastic Surgery, Amsterdam (Netherlands); Veldhuizen, J.F.H. [MRI Centre, Amsterdam (Netherlands); Manoliu, R.A. [MRI Centre, Amsterdam (Netherlands); VU University Medical Centre, Department of Radiology, Amsterdam (Netherlands)

    2014-06-15

    The recall of Poly Implant Prothese (PIP) silicone breast implants in 2010 resulted in large numbers of asymptomatic women with implants who underwent magnetic resonance imaging (MRI) screening. This study's aim was to assess the accuracy and interobserver variability of MRI screening in the detection of rupture and extracapsular silicone leakage. A prospective study included 107 women with 214 PIP implants who underwent explantation preceded by MRI. In 2013, two radiologists blinded for previous MRI findings or outcome at surgery, independently re-evaluated all MRI examinations. A structured protocol described the MRI findings. The ex vivo findings served as reference standard. In 208 of the 214 explanted prostheses, radiologists agreed independently about the condition of the implants. In five of the six cases they disagreed (2.6 %), but subsequently reached consensus. A sensitivity of 93 %, specificity of 93 %, positive predictive value of 77 % and negative predictive value of 98 % was found. The interobserver agreement was excellent (kappa value of 0.92). MRI has a high accuracy in diagnosing rupture in silicone breast implants. Considering the high kappa value of interobserver agreement, MRI appears to be a consistent diagnostic test. A simple, uniform classification, may improve communication between radiologist and plastic surgeon. (orig.)

  5. MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard

    International Nuclear Information System (INIS)

    Maijers, M.C.; Ritt, M.J.P.F.; Niessen, F.B.; Veldhuizen, J.F.H.; Manoliu, R.A.

    2014-01-01

    The recall of Poly Implant Prothese (PIP) silicone breast implants in 2010 resulted in large numbers of asymptomatic women with implants who underwent magnetic resonance imaging (MRI) screening. This study's aim was to assess the accuracy and interobserver variability of MRI screening in the detection of rupture and extracapsular silicone leakage. A prospective study included 107 women with 214 PIP implants who underwent explantation preceded by MRI. In 2013, two radiologists blinded for previous MRI findings or outcome at surgery, independently re-evaluated all MRI examinations. A structured protocol described the MRI findings. The ex vivo findings served as reference standard. In 208 of the 214 explanted prostheses, radiologists agreed independently about the condition of the implants. In five of the six cases they disagreed (2.6 %), but subsequently reached consensus. A sensitivity of 93 %, specificity of 93 %, positive predictive value of 77 % and negative predictive value of 98 % was found. The interobserver agreement was excellent (kappa value of 0.92). MRI has a high accuracy in diagnosing rupture in silicone breast implants. Considering the high kappa value of interobserver agreement, MRI appears to be a consistent diagnostic test. A simple, uniform classification, may improve communication between radiologist and plastic surgeon. (orig.)

  6. PRELIMINARY RESULTS OF THE COMPARISON OF SATELLITE IMAGERS USING TUZ GÖLÜ AS A REFERENCE STANDARD

    Directory of Open Access Journals (Sweden)

    H. Özen

    2012-07-01

    Full Text Available Earth surfaces, such as deserts, salt lakes, and playas, have been widely used in the vicarious radiometric calibration of optical earth observation satellites. In 2009, the Infrared and Visible Optical Sensors (IVOS sub-group of the Committee of Earth Observation Satellites (CEOS Working Group on Calibration and Validation (WGCV designated eight LANDNET reference sites to focus international efforts, facilitate traceability and enable the establishment of measurement "best practices." With support from the European Space Agency (ESA, one of the LANDNET sites, the Tuz Gölü salt lake located in central Turkey, was selected to host a cross-comparison of measurement instrumentation and methodologies conducted by 11 different ground teams across the globe. This paper provides an overview of the preliminary results of the cross-comparison of the ground-based spectral measurements made during the CEOS Land Comparison 13-27 August, 2010 with the simultaneous satellite image data acquisitions of the same site.

  7. STANDARDIZATION OF GLYCOHEMOGLOBIN RESULTS AND REFERENCE VALUES IN WHOLE-BLOOD STUDIED IN 103 LABORATORIES USING 20 METHODS

    NARCIS (Netherlands)

    WEYKAMP, CW; PENDERS, TJ; MUSKIET, FAJ; VANDERSLIK, W

    We investigated the effect of calibration with lyophilized calibrators on whole-blood glycohemoglobin (glyHb) results. One hundred three laboratories, using 20 different methods, determined glyHb in two lyophilized calibrators and two whole-blood samples. For whole-blood samples with low (5%) and

  8. ASTM reference radiologic digital image standards

    International Nuclear Information System (INIS)

    Wysnewski, R.; Wysnewski, D.

    1996-01-01

    ASTM Reference Radiographs have been essential in defining industry's material defect grade levels for many years. ASTM Reference Radiographs are used extensively as even the American Society for Metals Nondestructive Inspection and Quality Control Metals Handbook, Volume 11, eighth edition refers to ASTM Standard Reference Radiographs. The recently published E 1648 Standard Reference Radiographs for Examination of Aluminum Fusion Welds is a prime example of the on-going need for these references. To date, 14 Standard Reference Radiographs have been published to characterize material defects. Standard Reference Radiographs do not adequately address film-less radiologic methods. There are differences in mediums to content with. On a computer CRT defect indications appear differently when compared to indications viewed in a radiograph on a view box. Industry that uses non-film radiologic methods of inspection can be burdened with additional time and money developing internal standard reference radiologic images. These references may be deemed necessary for grading levels of product defects. Because there are no ASTM Standard Reference Radiologic data files for addressing this need in the industry, the authors of this paper suggested implementing a method for their creation under ASTM supervision. ASTM can assure continuity to those users making the transition from analog radiographic images to digital image data by swiftly addressing the requirements for reference digital image standards. The current status and possible future activities regarding a method to create digital data files is presented in this paper summary

  9. Standard digital reference images for titanium castings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 The digital reference images provided in the adjunct to this standard illustrate various types and degrees of discontinuities occurring in titanium castings. Use of this standard for the specification or grading of castings requires procurement of the adjunct digital reference images, which illustrate the discontinuity types and severity levels. They are intended to provide the following: 1.1.1 A guide enabling recognition of titanium casting discontinuities and their differentiation both as to type and degree through digital radiographic examination. 1.1.2 Example digital radiographic illustrations of discontinuities and a nomenclature for reference in acceptance standards, specifications and drawings. 1.2 The digital reference images consist of seventeen digital files each illustrating eight grades of increasing severity. The files illustrate seven common discontinuity types representing casting sections up to 1-in. (25.4-mm). 1.3 The reference radiographs were developed for casting sections up to 1...

  10. Development of standard reference samples for diffractometry

    International Nuclear Information System (INIS)

    Galvao, Antonio de Sant'Ana

    2011-01-01

    In this work, samples of standard reference materials for diffractometry of polycrystals were developed. High-purity materials were submitted to mechanical and thermal treatments in order to present the adequate properties to be used as high-quality standard reference materials for powder diffraction, comparable to the internationally recognized produced by the USA National Institute of Standards and Technology NIST, but at lower costs. The characterization of the standard materials was performed by measurements in conventional X-ray diffraction diffractometers, high resolution neutron diffraction and high-resolution synchrotron diffraction. The lattice parameters were calculated by extrapolation of the values obtained from each X-ray reflection against cos 2 θ by the Least-Squares Method. The adjustments were compared to the values obtained by the Rietveld Method, using program GSAS. The materials thus obtained were the α-alumina, yttrium oxide, silicon, cerium oxide, lanthanum hexaboride and lithium fluoride. The standard reference materials produced present quality similar or, in some cases, superior to the standard reference materials produced and commercialized by the NIST. (author)

  11. Strategies for building reference standards for autoantibodies

    Directory of Open Access Journals (Sweden)

    Joanna eSheldon

    2015-04-01

    Full Text Available Producing robust, certified, traceable reference material for autoantibody testing is a vital element in maintaining the validity of results that are generated in the daily clinical laboratory routine. This is a huge challenge because of the high number of variables involved in the detection and measurement of the autoantibodies. The production of such materials is time consuming and needs rigorous attention to detail; this is best achieved by an overarching independent body who will oversee the process in a not for profit manner.Much effort has been made to build international standards for quantitative and qualitative assays based on monoclonal antibodies, obtained from affinity purification and plasmapheresis. The big challenge is to respect individual differences in immune response to the same antigen. A promising ongoing initiative is the construction of pools with monospecific samples from different individuals.

  12. Reference Data for Standardized Quality of Life Questionnaires in Indian Patients with Brain Metastases from Non-small Cell Lung Cancer: Results from a Prospective Study.

    Science.gov (United States)

    Aggarwal, Jaiprakash; Chakraborty, Santam; Ghosh Laskar, Sarbani; Patil, Vijay M; Prabhash, Kumar; Bhattacharya, Atanu; Noronha, Vanita; Purandare, Nilendu C; Joshi, Amit; Mummudi, Naveen; Arora, Jitendra; Badhe, Rupali

    2017-04-10

    Reference data for European Organization for Research and Treatment of Cancer (EORTC) quality of life questionnaires do not include studies from the Indian subcontinent. The objective of the current study was to establish a reference dataset for Indian patients of non-small cell lung cancer (NSCLC) presenting with brain metastases (BM). One hundred forty patients with NSCLC with BM treated between 2012-2015 were registered in a prospective cohort study (CTRI/2013/01/003299). The baseline quality of life was evaluated using the EORTC general quality of life questionnaire QLQ-C30 and lung cancer specific module LC13. Minimum important difference (MID) scores for individual domains of the EORTC QLQ-C30 and LC13 questionnaires were derived (MID = 0.2 x standard deviation) from the reference data for patients with recurrent/metastatic lung cancers. In addition, a systematic review was conducted to identify studies reporting baseline quality of life scores for recurrent/metastatic NSCLC. Scores of several functional as well as symptom scales in the current NSCLC population differed by more than the MID from the baseline mean scores in the reference EORTC population as well as that reported from other studies. Differences in mean score from the EORTC reference data ranged from 6.2 and 9.4 points for the role functioning and cognitive functioning domains. In the symptom scales, the largest differences were observed for the financial difficulties (23.9) scores for the QLQ-C30 and peripheral neuropathy (21.7) for LC13 questionnaires. The current study demonstrates that baseline reference scores need to be established for patients from the Indian subcontinent. The findings from the current study have important implications for studies employing quality of life (QOL) assessment in the Indian NSCLC patient population.

  13. 15 CFR 230.3 - New Standard Reference Materials.

    Science.gov (United States)

    2010-01-01

    ... NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE STANDARD REFERENCE MATERIALS STANDARD REFERENCE MATERIALS General Information § 230.3 New Standard Reference Materials. When new SRM's... scientific and trade journals. ...

  14. Practical reference - radiation standards in Canada

    International Nuclear Information System (INIS)

    1983-07-01

    In developing a policy that will require licensees to calibrate their radiation dose measuring devices and trace such calibrations to approved reference standards, the AECB has consulted recognized experts. This document presents the experts' reports and recommendations which will be considered in finalizing the policy

  15. ENAA of iodine in standard reference material lyophilized human urine

    International Nuclear Information System (INIS)

    Zhang Yongbao; Wang Ke; Wang Ganfeng

    1997-01-01

    The contents of iodine in two kinds of standard reference materials lyophilized human urine are determined by ENAA. The sensitivity of this method is ten times higher than that of TNAA, and the relative standard deviations of ten measurements are 2.9% and 3.3%, respectively. Two certificated reference samples are used for verification of the analysis. The analytical results are in agreement with the recommended values, and the relative error is less than 3%

  16. Generation of gaseous methanol reference standards

    International Nuclear Information System (INIS)

    Geib, R.C.

    1991-01-01

    Methanol has been proposed as an automotive fuel component. Reliable, accurate methanol standards are essential to support widespread monitoring programs. The monitoring programs may include quantification of methanol from tailpipe emissions, evaporative emissions, plus ambient air methanol measurements. This paper will present approaches and results in the author's investigation to develop high accuracy methanol standards. The variables upon which the authors will report results are as follows: (1) stability of methanol gas standards, the studies will focus on preparation requirements and stability results from 10 to 1,000 ppmv; (2) cylinder to instrument delivery system components and purge technique, these studies have dealt with materials in contact with the sample stream plus static versus flow injection; (3) optimization of gas chromatographic analytical system will be discussed; (4) gas chromatography and process analyzer results and utility for methanol analysis will be presented; (5) the accuracy of the methanol standards will be qualified using data from multiple studies including: (a) gravimetric preparation; (b) linearity studies; (c) independent standards sources such as low pressure containers and diffusion tubes. The accuracy will be provided as a propagation of error from multiple sources. The methanol target concentrations will be 10 to 500 ppmv

  17. Electrothermal frequency references in standard CMOS

    CERN Document Server

    Kashmiri, S Mahdi

    2013-01-01

    This book describes an alternative method of accurate on-chip frequency generation in standard CMOS IC processes. This method exploits the thermal-diffusivity of silicon, the rate at which heat diffuses through a silicon substrate.  This is the first book describing thermal-diffusivity-based frequency references, including the complete theoretical methodology supported by practical realizations that prove the feasibility of the method.  Coverage also includes several circuit and system-level solutions for the analog electronic circuit design challenges faced.   ·         Surveys the state-of-the-art in all-silicon frequency references; ·         Examines the thermal properties of silicon as a solution for the challenge of on-chip accurate frequency generation; ·         Uses simplified modeling approaches that allow an electronics engineer easily to simulate the electrothermal elements; ·         Follows a top-down methodology in circuit design, in which system-level des...

  18. Fabricating defensible reference standards for the NDA lab

    Energy Technology Data Exchange (ETDEWEB)

    Ceo, R.N.; May, P.K. [Oak Ridge Y-12 Plant, TN (United States)

    1997-11-01

    Nondestructive analysis (NDA) is performed at the Oak Ridge Y-12 Plant in support of the enriched uranium operations. Process materials are analyzed using gamma ray- and neutron-based instruments including segmented gamma scanners, solution assay systems, and an active well coincidence counter. Process wastes are also discarded based on results of these measurements. Good analytical practice, as well as applicable regulations, mandates that these analytical methods be calibrated using reference materials traceable to the national standards base. Reference standards for NDA instruments are not commercially available owing to the large quantities of special nuclear materials involved. Instead, representative materials are selected from each process stream, then thoroughly characterized by methods that are traceable to the national standards base. This paper discusses the process materials to be analyzed, reference materials selected for calibrating each NDA instrument, and details of their characterization and fabrication into working calibrations standards. Example calibration curves are also presented. 4 figs.

  19. Fabricating defensible reference standards for the NDA lab

    International Nuclear Information System (INIS)

    Ceo, R.N.; May, P.K.

    1997-01-01

    Nondestructive analysis (NDA) is performed at the Oak Ridge Y-12 Plant in support of the enriched uranium operations. Process materials are analyzed using gamma ray- and neutron-based instruments including segmented gamma scanners, solution assay systems, and an active well coincidence counter. Process wastes are also discarded based on results of these measurements. Good analytical practice, as well as applicable regulations, mandates that these analytical methods be calibrated using reference materials traceable to the national standards base. Reference standards for NDA instruments are not commercially available owing to the large quantities of special nuclear materials involved. Instead, representative materials are selected from each process stream, then thoroughly characterized by methods that are traceable to the national standards base. This paper discusses the process materials to be analyzed, reference materials selected for calibrating each NDA instrument, and details of their characterization and fabrication into working calibrations standards. Example calibration curves are also presented. 4 figs

  20. On criteria for examining analysis quality with standard reference material

    International Nuclear Information System (INIS)

    Yang Huating

    1997-01-01

    The advantages and disadvantages and applicability of some criteria for examining analysis quality with standard reference material are discussed. The combination of the uncertainties of the instrument examined and the reference material should be determined on the basis of specific situations. Without the data of the instrument's uncertainty, it would be applicable to substitute the standard deviation multiplied by certain times for the uncertainty. The result of the examining should not result in more error reported in routine measurements than it really is. Over strict examining should also be avoided

  1. Halogens determination in vegetable NBS standard reference materials

    International Nuclear Information System (INIS)

    Stella, R.; Genova, N.; Di Casa, M.

    1977-01-01

    Levels of all four halogens in Orchard Leaves, Pine Needles and Tomato Leaves NBS reference standards were determined. For fluorine a spiking isotope dilution method was used followed by HF absorption on glass beads. Instrumental nuclear activation analysis was adopted for chlorine and bromine determination. Radiochemical separation by a distillation procedure was necessary for iodine nuclear activation analysis after irradiation. Activation parameters of Cl, Br and I are reported. Results of five determinations for each halogen in Orchard Leaves, Pine Needles and Tomato Leaves NBS Standard Materials and Standard deviations of the mean are reported. (T.I.)

  2. Determination of polybrominated diphenyl ethers in environmental standard reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Stapleton, Heather M.; Schantz, Michele M.; Wise, Stephen A. [National Institute of Standards and Technology, Analytical Chemistry Division, Gaithersburg, MD (United States); Keller, Jennifer M.; Kucklick, John R. [National Institute of Standards and Technology, Analytical Chemistry Division, Hollings Marine Laboratory, Charleston, SC (United States); Leigh, Stefan D. [National Institute of Standards and Technology, Statistical Engineering Division, Gaithersburg, MD (United States)

    2007-04-15

    Standard reference materials (SRMs) are valuable tools in developing and validating analytical methods to improve quality assurance standards. The National Institute of Standards and Technology (NIST) has a long history of providing environmental SRMs with certified concentrations of organic and inorganic contaminants. Here we report on new certified and reference concentrations for 27 polybrominated diphenyl ether (PBDE) congeners in seven different SRMs: cod-liver oil, whale blubber, fish tissue (two materials), mussel tissue and sediment (two materials). PBDEs were measured in these SRMs, with the lowest concentrations measured in mussel tissue (SRM 1974b) and the highest in sediment collected from the New York/New Jersey Waterway (SRM 1944). Comparing the relative PBDE congener concentrations within the samples, we found the biota SRMs contained primarily tetrabrominated and pentabrominated diphenyl ethers, whereas the sediment SRMs contained primarily decabromodiphenyl ether (BDE 209). The cod-liver oil (SRM 1588b) and whale blubber (SRM 1945) materials were also found to contain measurable concentrations of two methoxylated PBDEs (MeO-BDEs). Certified and reference concentrations are reported for 12 PBDE congeners measured in the biota SRMs and reference values are available for two MeO-BDEs. Results from a sediment interlaboratory comparison PBDE exercise are available for the two sediment SRMs (1941b and 1944). (orig.)

  3. Standards for reference reactor physics measurements

    International Nuclear Information System (INIS)

    Harris, D.R.; Cokinos, D.M.; Uotinen, V.

    1990-01-01

    Reactor physics analysis methods require experimental testing and confirmation over the range of practical reactor configurations and states. This range is somewhat limited by practical fuel types such as actinide oxides or carbides enclosed in metal cladding. On the other hand, this range continues to broaden because of the trend of using higher enrichment, if only slightly enriched, electric utility fuel. The need for experimental testing of the reactor physics analysis methods arises in part because of the continual broadening of the range of core designs, and in part because of the nature of the analysis methods. Reactor physics analyses are directed primarily at the determination of core reactivities and reaction rates, the former largely for reasons of reactor control, and the latter largely to ensure that material limitations are not violated. Errors in these analyses can be regarded as being from numerics, from the data base, and from human factors. For numerical, data base, and human factor reasons, then, it is prudent and customary to qualify reactor physical analysis methods against experiments. These experiments can be treated as being at low power or at high power, and each of these types is subject to an American National Standards Institute standard. The purpose of these standards is to aid in improving and maintaining adequate quality in reactor physics methods, and it is from this point of view that the standards are examined here

  4. 15 CFR 200.105 - Standard reference data.

    Science.gov (United States)

    2010-01-01

    ... for application in energy, environment and health, industrial process design, materials durability... application in research, development, engineering design, and commerce. The Office of Standard Reference Data...

  5. Characterization of the NIST shellfish Standard Reference Material 4358

    International Nuclear Information System (INIS)

    Nour, S.; Inn, K.G.W.; Filliben, J.; Gaast van der, H.; Men, L.C.; Calmet, D.; Altzitzoglou, T.; Povinec, P.; Takata, Y.; Wisdom, M.

    2013-01-01

    A new shellfish Standard Reference Material 4358 was developed by the National Institute of Standards and Technology through an international interlaboratory comparison that involved twelve laboratories-participants from nine countries. The results from the participants were statistically evaluated, and the most robust certified values were based on the median of laboratories’ reported means and the uncertainties derived using the bootstrap method. Massic activity certified values were established for fourteen radionuclides, five activity ratios, and informational massic activity values for eight more radionuclides and two activity ratios. (author)

  6. Standard Reference Development of nuclear material for Tensile and Hardness Test Properties

    International Nuclear Information System (INIS)

    Choo, Y. S.; Kim, D. S.; Yoo, B. O.; Ahn, S. B.; Baik, S. J.; Chun, Y. B.; Kim, K. H.; Hong, K. P.; Ryu, W. S.

    2007-12-01

    Standard reference is a official approved data such a coefficient of physics, approved material properties, and etc., which should be analyzed and evaluated by scientific method to acquire official approval for accuracy and credibility of measured data and information. So it could be used broadly and continuously by various fields of nation and society. It is classified to effective standard reference, verified standard reference, and certified standard reference. There are sixteen fields in designated standard references such a physical chemistry field, material field, metal field, and the others. The standard reference of neutron irradiated nuclear structural material is classified to metal field. This report summarized the whole processes about data collection, data production, data evaluation and the suggestion of details evaluation technical standard for tensile and hardness properties, which were achieved by carry out the project 'nuclear material standard reference development' as a result

  7. Standard Reference Development of nuclear material for Tensile and Hardness Test Properties

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Y. S.; Kim, D. S.; Yoo, B. O.; Ahn, S. B.; Baik, S. J.; Chun, Y. B.; Kim, K. H.; Hong, K. P.; Ryu, W. S

    2007-12-15

    Standard reference is a official approved data such a coefficient of physics, approved material properties, and etc., which should be analyzed and evaluated by scientific method to acquire official approval for accuracy and credibility of measured data and information. So it could be used broadly and continuously by various fields of nation and society. It is classified to effective standard reference, verified standard reference, and certified standard reference. There are sixteen fields in designated standard references such a physical chemistry field, material field, metal field, and the others. The standard reference of neutron irradiated nuclear structural material is classified to metal field. This report summarized the whole processes about data collection, data production, data evaluation and the suggestion of details evaluation technical standard for tensile and hardness properties, which were achieved by carry out the project 'nuclear material standard reference development' as a result.

  8. Positive animal welfare states and reference standards for welfare assessment.

    Science.gov (United States)

    Mellor, D J

    2015-01-01

    Developments in affective neuroscience and behavioural science during the last 10-15 years have together made it increasingly apparent that sentient animals are potentially much more sensitive to their environmental and social circumstances than was previously thought to be the case. It therefore seems likely that both the range and magnitude of welfare trade-offs that occur when animals are managed for human purposes have been underestimated even when minimalistic but arguably well-intentioned attempts have been made to maintain high levels of welfare. In light of these neuroscience-supported behaviour-based insights, the present review considers the extent to which the use of currently available reference standards might draw attention to these previously neglected areas of concern. It is concluded that the natural living orientation cannot provide an all-embracing or definitive welfare benchmark because of its primary focus on behavioural freedom. However assessments of this type, supported by neuroscience insights into behavioural motivation, may now carry greater weight when used to identify management practices that should be avoided, discontinued or substantially modified. Using currently accepted baseline standards as welfare reference points may result in small changes being accorded greater significance than would be the case if they were compared with higher standards, and this could slow the progress towards better levels of welfare. On the other hand, using "what animals want" as a reference standard has the appeal of focusing on the specific resources or conditions the animals would choose themselves and can potentially improve their welfare more quickly than the approach of making small increments above baseline standards. It is concluded that the cautious use of these approaches in different combinations could lead to recommendations that would more effectively promote positive welfare states in hitherto neglected areas of concern.

  9. Quality of Standard Reference Materials for Short Time Activation Analysis

    International Nuclear Information System (INIS)

    Ismail, S.S.; Oberleitner, W.

    2003-01-01

    Some environmental reference materials (CFA-1633 b, IAEA-SL-1, SARM-1,BCR-176, Coal-1635, IAEA-SL-3, BCR-146, and SRAM-5) were analysed by short-time activation analysis. The results show that these materials can be classified in three groups, according to their activities after irradiation. The obtained results were compared in order to create a quality index for determination of short-lived nuclides at high count rates. It was found that Cfta is not a suitable standard for determining very short-lived nuclides (half-lives<1 min) because the activity it produces is 15-fold higher than that SL-3. Biological reference materials, such as SRM-1571, SRM-1573, SRM-1575, SRM-1577, IAEA-392, and IAEA-393, were also investigated by a higher counting efficiency system. The quality of this system and its well-type detector for investigating short-lived nuclides was discussed

  10. Japanese tea leaves: a possible biological standard reference material

    International Nuclear Information System (INIS)

    Fuwa, Keiichiro; Notsu, Kenji; Tsunoda, Kin-ichi; Kato, Hideaki; Yamamoto, Yuko.

    1978-01-01

    Japanese Tea Leaves, prepared by pulverizing with an agate ball mill and sieving with a Saran fiber sieve (50 mesh) were assessed as a possible biological standard reference material for elemental analysis. The metal content of the tea leaves was determined independently at two laboratories using atomic absorption and flame emission spectrometry. Neutron activation analysis was also performed to determine the content (21 elements) of Tea Leaves. For some elements the result from the various methods were compared. The characteristics of Tea Leaves are discussed and the elemental composition is compared to that of Orchard Leaves (NBS SRM, 1571). The most significant characteristic of Tea Leaves was the high manganese content. (auth.)

  11. Standard reference materials analysis for MINT Radiocarbon Laboratory

    International Nuclear Information System (INIS)

    Noraishah Othman; Kamisah Alias; Nasasni Nasrul

    2004-01-01

    As a follow-up to the setting up of the MINT Radiocarbon Dating facility. an exercise on the IAEA standard reference materials was carried out. Radiocarbon laboratories frequently used these 8 natural samples to verify their systems. The materials were either pretreated or analysed directly to determine the activity of 14 C isotopes of the five samples expressed in % Modern (pMC) terms and to make recommendations on further use of these materials. We present the results of the five materials and discuss the analyses that were undertaken. (Author)

  12. The Quality Control of Reference Standards in Metrology Dosimetry

    International Nuclear Information System (INIS)

    Lazarevic, Dj.; Ciraj Bjelac, O.; Kovacevic, M.; Vukcevic, M.

    2008-01-01

    This works presents the quality control tests applied to two types of ionization chambers with suitable electrometers. Measuring assemblies were tested in order to assess their performance and adequacy for use as reference standards in ionising radiation metrology laboratory for calibrations in the field of radiotherapy and radiation protection. Two types of ionizing chambers (Farmer type, 0.6 cm 3 and spherical ionizing chamber, 1 l) with suitable electrometers were tested. Following test were performed: repeatability, long term stability, polarity and leakage current measurement. All tested measuring assemblies demonstrated proper performance, correctness and high reliance of measurements, since all implemented quality control test results were within acceptable limits. (author)

  13. Physical fitness reference standards in European children: the IDEFICS study.

    Science.gov (United States)

    De Miguel-Etayo, P; Gracia-Marco, L; Ortega, F B; Intemann, T; Foraita, R; Lissner, L; Oja, L; Barba, G; Michels, N; Tornaritis, M; Molnár, D; Pitsiladis, Y; Ahrens, W; Moreno, L A

    2014-09-01

    A low fitness status during childhood and adolescence is associated with important health-related outcomes, such as increased future risk for obesity and cardiovascular diseases, impaired skeletal health, reduced quality of life and poor mental health. Fitness reference values for adolescents from different countries have been published, but there is a scarcity of reference values for pre-pubertal children in Europe, using harmonised measures of fitness in the literature. The IDEFICS study offers a good opportunity to establish normative values of a large set of fitness components from eight European countries using common and well-standardised methods in a large sample of children. Therefore, the aim of this study is to report sex- and age-specific fitness reference standards in European children. Children (10,302) aged 6-10.9 years (50.7% girls) were examined. The test battery included: the flamingo balance test, back-saver sit-and-reach test (flexibility), handgrip strength test, standing long jump test (lower-limb explosive strength) and 40-m sprint test (speed). Moreover, cardiorespiratory fitness was assessed by a 20-m shuttle run test. Percentile curves for the 1st, 3rd, 10th, 25th, 50th, 75th, 90th, 97th and 99th percentiles were calculated using the General Additive Model for Location Scale and Shape (GAMLSS). Our results show that boys performed better than girls in speed, lower- and upper-limb strength and cardiorespiratory fitness, and girls performed better in balance and flexibility. Older children performed better than younger children, except for cardiorespiratory fitness in boys and flexibility in girls. Our results provide for the first time sex- and age-specific physical fitness reference standards in European children aged 6-10.9 years.

  14. Thermal-Diffusivity-Based Frequency References in Standard CMOS

    NARCIS (Netherlands)

    Kashmiri, S.M.

    2012-01-01

    In recent years, a lot of research has been devoted to the realization of accurate integrated frequency references. A thermal-diffusivity-based (TD) frequency reference provides an alternative method of on-chip frequency generation in standard CMOS technology. A frequency-locked loop locks the

  15. Nuclear microprobe analysis of the standard reference materials

    International Nuclear Information System (INIS)

    Jaksic, M.; Fazinic, S.; Bogdanovic, I.; Tadic, T.

    2002-01-01

    Most of the presently existing Standard Reference Materials (SRM) for nuclear analytical methods are certified for the analyzed mass of the order of few hundred mg. Typical mass of sample which is analyzed by PIXE or XRF methods is very often below 1 mg. By the development of focused proton or x-ray beams, masses which can be typically analyzed go down to μg or even ng level. It is difficult to make biological or environmental SRMs which can give desired homogeneity at such low scale. However, use of fundamental parameter quantitative evaluation procedures (absolute method), minimize needs for SRMs. In PIXE and micro PIXE setup at our Institute, fundamental parameter approach is used. For exact calibration of the quantitative analysis procedure just one standard sample is needed. In our case glass standards which showed homogeneity down to micron scale were used. Of course, it is desirable to use SRMs for quality assurance, and therefore need for homogenous materials can be justified even for micro PIXE method. In this presentation, brief overview of PIXE setup calibration is given, along with some recent results of tests of several SRMs

  16. Bibliographic Citations With Special Reference Indian Bibliographic Standard

    Directory of Open Access Journals (Sweden)

    Reshmi Sarkar

    2015-08-01

    Full Text Available Bibliographic citation is playing an important role today to ensure the completeness of all research activities. They occupy an integral part as a reference in all types of resources need. The author while writing a paper takes the references from a number of documents and finally quotes them with its bibliographic details to recognize the work of earlier authors in the same field of study. With the virtually exponential growth in the research literatures throughout the 20th century it has become clear that the larger the literature the more difficult are the problems caused by poorly crafted bibliographic references. Scholarly societies like publishers of research journals have either produced their own or have endorsed common bibliographic style manuals or standards. In this study we have studied several style manuals and standards for bibliographic referencing and several editorial guidelines for this purpose to compare them. Indian bibliographic standard gets special attention.

  17. Universal Reference RNA as a standard for microarray experiments

    Directory of Open Access Journals (Sweden)

    Fero Michael

    2004-03-01

    Full Text Available Abstract Background Obtaining reliable and reproducible two-color microarray gene expression data is critically important for understanding the biological significance of perturbations made on a cellular system. Microarray design, RNA preparation and labeling, hybridization conditions and data acquisition and analysis are variables difficult to simultaneously control. A useful tool for monitoring and controlling intra- and inter-experimental variation is Universal Reference RNA (URR, developed with the goal of providing hybridization signal at each microarray probe location (spot. Measuring signal at each spot as the ratio of experimental RNA to reference RNA targets, rather than relying on absolute signal intensity, decreases variability by normalizing signal output in any two-color hybridization experiment. Results Human, mouse and rat URR (UHRR, UMRR and URRR, respectively were prepared from pools of RNA derived from individual cell lines representing different tissues. A variety of microarrays were used to determine percentage of spots hybridizing with URR and producing signal above a user defined threshold (microarray coverage. Microarray coverage was consistently greater than 80% for all arrays tested. We confirmed that individual cell lines contribute their own unique set of genes to URR, arguing for a pool of RNA from several cell lines as a better configuration for URR as opposed to a single cell line source for URR. Microarray coverage comparing two separately prepared batches each of UHRR, UMRR and URRR were highly correlated (Pearson's correlation coefficients of 0.97. Conclusion Results of this study demonstrate that large quantities of pooled RNA from individual cell lines are reproducibly prepared and possess diverse gene representation. This type of reference provides a standard for reducing variation in microarray experiments and allows more reliable comparison of gene expression data within and between experiments and

  18. Newly developed standard reference materials for organic contaminant analysis

    Energy Technology Data Exchange (ETDEWEB)

    Poster, D.; Kucklick, J.; Schantz, M.; Porter, B.; Wise, S. [National Inst. of Stand. and Technol., Gaithersburg, MD (USA). Center for Anal. Chem.

    2004-09-15

    The National Institute of Standards and Technology (NIST) has issued a number of Standard Reference Materials (SRM) for specified analytes. The SRMs are biota and biological related materials, sediments and particle related SRMs. The certified compounds for analysis are polychlorinated biphenyls (PCB), polycylic aromatic hydrocarbons (PAH) and their nitro-analogues, chlorinated pesticides, methylmercury, organic tin compounds, fatty acids, polybrominated biphenyl ethers (PBDE). The authors report on origin of materials and analytic methods. (uke)

  19. Standard digital reference images for inspection of aluminum castings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These digital reference images illustrate the types and degrees of discontinuities that may be found in aluminum-alloy castings. The castings illustrated are in thicknesses of 1/ 4 in. [6.35 mm] and 3/4 in. [19.1mm]. 1.2 All areas of this standard may be open to agreement between the cognizant engineering organization and the supplier, or specific direction from the cognizant engineering organization. These items should be addressed in the purchase order or the contract. 1.3 The values stated in inch-pound units are to be regarded as standard. 1.4 These digital reference images are not intended to illustrate the types and degrees of discontinuities found in aluminum-alloy castings when performing film radiography. If performing film radiography of aluminum-alloy castings, refer to Reference Radiographs E 155. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and he...

  20. A routine chromium determination in biological materials; application to various reference materials and standard reference materials

    International Nuclear Information System (INIS)

    Tjioe, P.S.; Goeij, J.J.M. de; Volkers, K.J.

    1979-01-01

    The determination limit under standard working conditions of chromium in biological materials is discussed. Neutron activation analysis and atomic spectrometry have been described for some analytical experiences with NBS SRM 1577 reference material. The chromium determination is a part of a larger multi-element scheme for the determination of 12 elements in biological materials

  1. Consensus values for NIST biological and environmental Standard Reference Materials

    International Nuclear Information System (INIS)

    Roelandts, I.; Gladney, E.S.

    1998-01-01

    The National Institute of Standards and Technology (NIST, formerly the National Bureau of Standards or NBS) has produced numerous Standard Reference Materials (SRM) for use in biological and environmental analytical chemistry. The value listed on the ''NIST Certificate of Analysis'' is the present best estimate of the ''true'' concentration of that element and is not expected to deviate from that concentration by more than the stated uncertainty. However, NIST does not certify the elemental concentration of every constituent and the number of elements reported in the NIST programs tends to be limited.Numerous analysts have published concentration data on these reference materials. Major journals in analytical chemistry, books, proceedings and ''technical reports'' have been surveyed to collect these available literature values. A standard statistical approach has been employed to evaluate the compiled data. Our methodology has been developed in a series of previous papers. Some subjective criteria are first used to reject aberrant data. Following these eliminations, an initial arithmetic mean and standard deviation (S.D.) are computed from remaining data for each element. All data now outside two S.D. from the initial mean are dropped and a second mean and S.D. recalculated. These final means and associated S.D. are reported as ''consensus values'' in our tables. (orig.)

  2. Reference standard for serum bile acids in pregnancy.

    LENUS (Irish Health Repository)

    2012-01-31

    Please cite this paper as: Egan N, Bartels A, Khashan A, Broadhurst D, Joyce C, O\\'Mullane J, O\\'Donoghue K. Reference standard for serum bile acids in pregnancy. BJOG 2012;00:000-000. DOI: 10.1111\\/j.1471-0528.2011.03245.x. Objective Obstetric cholestasis (OC) is a liver disorder characterised by pruritus and elevated serum bile acids (SBA) that affects one in 200 pregnant women. It is associated with adverse perinatal outcomes such as premature delivery and stillbirth. Mild OC is defined as SBA levels of 10-39 mumol\\/l, and severe OC is defined by levels >40 mumol\\/l. SBA levels in normal pregnancy have not been investigated. We aimed to establish reference values for SBA in healthy pregnant women across different trimesters of pregnancy. Design Cross-sectional analysis of SBA levels. Setting A large tertiary referral university teaching maternity hospital. Population Healthy pregnant women with a singleton pregnancy and a body mass index (BMI) < 40, excluding women with significant alcohol intake, history of liver disease, prior cholecystectomy and OC. Methods Cross-sectional analysis of SBA levels at 12, 20, 28 and 36 weeks of gestation, and on days 1-3 postpartum. Main outcome measures SBA levels in mumol\\/l. Results A total of 219 women attending for antenatal care were recruited, and SBA levels were assayed at 12, 20, 28 and 36 weeks of gestation, and up to 72 hours postpartum (n = 44-49 cases at each stage). The majority were white European women, with a median age of 30 years (range 17-46 years) and median BMI of 25 (range 18-38). Values of SBA ranged from 0.3 to 9.8 mumol\\/l in 216 women, with only three measurements outside this range. There were no significant changes throughout pregnancy. Conclusions SBA values in uncomplicated pregnancies are consistent, regardless of gestation, and are not elevated in pregnancy. The current reference values for the diagnosis of OC appear to be appropriate.

  3. 78 FR 13243 - Updates to Standards Incorporated by Reference; Reapproved ASTM Standards; Technical Amendment

    Science.gov (United States)

    2013-02-27

    ... Characteristics of Plastic Film 2009)[egr]1. and Sheeting. Standard Specification for F682-82a F682-82a 46 56.01-2... (Reapproved Standard Test Method for Determining Gas 2009)[egr]1. Permeability Characteristics of Plastic Film... Permeability Characteristics of Plastic Film and Sheeting (approved May 1, 2009), incorporation by reference...

  4. Determination of trace elements in standard reference materials by the ko-standardization method

    International Nuclear Information System (INIS)

    Smodis, B.; Jacimovic, R.; Stegnar, P.; Jovanovic, S.

    1990-01-01

    The k o -standardization method is suitable for routine multielement determinations by reactor neutron activation analysis (NAA). Investigation of NIST standard reference materials SRM 1571 Orchard Leaves, SRM 1572 Citrus leaves, and SRM 1573 Tomato Leaves showed the systematic error of 12 certified elements determined to be less than 8%. Thirty-four elements were determined in NIST proposed SRM 1515 Apple Leaves

  5. A reference standard-based quality assurance program for radiology.

    Science.gov (United States)

    Liu, Patrick T; Johnson, C Daniel; Miranda, Rafael; Patel, Maitray D; Phillips, Carrie J

    2010-01-01

    The authors have developed a comprehensive radiology quality assurance (QA) program that evaluates radiology interpretations and procedures by comparing them with reference standards. Performance metrics are calculated and then compared with benchmarks or goals on the basis of published multicenter data and meta-analyses. Additional workload for physicians is kept to a minimum by having trained allied health staff members perform the comparisons of radiology reports with the reference standards. The performance metrics tracked by the QA program include the accuracy of CT colonography for detecting polyps, the false-negative rate for mammographic detection of breast cancer, the accuracy of CT angiography detection of coronary artery stenosis, the accuracy of meniscal tear detection on MRI, the accuracy of carotid artery stenosis detection on MR angiography, the accuracy of parathyroid adenoma detection by parathyroid scintigraphy, the success rate for obtaining cortical tissue on ultrasound-guided core biopsies of pelvic renal transplants, and the technical success rate for peripheral arterial angioplasty procedures. In contrast with peer-review programs, this reference standard-based QA program minimizes the possibilities of reviewer bias and erroneous second reviewer interpretations. The more objective assessment of performance afforded by the QA program will provide data that can easily be used for education and management conferences, research projects, and multicenter evaluations. Additionally, such performance data could be used by radiology departments to demonstrate their value over nonradiology competitors to referring clinicians, hospitals, patients, and third-party payers. Copyright 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  6. Neutron activation analysis for certification of standard reference materials

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Perez Zayas, G.; Hernandez Rivero, A.; Ribeiro Guevara, S.

    1996-01-01

    Neutron activation analysis is used extensively as one of the analytical techniques in the certification of standard reference materials. Characteristics of neutron activation analysis which make it valuable in this role are: accuracy multielemental capability to asses homogeneity, high sensitivity for many elements, and essentially non-destructive method. This paper report the concentrations of 30 elements (major, minor and trace elements) in four Cuban samples. The samples were irradiated in a thermal neutron flux of 10 12- 10 13 n.cm 2. s -1. The gamma ray spectra were measured by HPGe detectors and were analyzed using ACTAN program development in Center of Applied Studies for Nuclear Development

  7. Certification of standard reference materials employing neutron activation analysis

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Hernandez Rivero, A.; Molina Insfran, J.; Ribeiro Guevara, S.; Santana Encinosa, C.; Perez Zayas, G.

    1997-01-01

    Neutron activation analysis (Naa) is used extensively as one of the analytical techniques in the certification of standard reference materials (Srm). Characteristics of Naa which make it valuable in this role are: accuracy; multielemental capability; ability to assess homogeneity; high sensitivity for many elements, and essentially non-destructive method. This paper reports the concentrations of thirty elements (major, minor and trace elements) in four Cuban Srm's. The samples were irradiated in a thermal neutron flux of 10 12 -10 13 neutrons.cm -2 .s -1 . The gamma-ray spectra were measured by HPGe detectors and were analysed using ACTAN program, developed in CEADEN. (author) [es

  8. Development of the NBS beryllium isotopic standard reference material

    International Nuclear Information System (INIS)

    Inn, K.G.W; Fassett, J.D.; Coursey, B.M.; Walker, R.L.; Raman, S.

    1987-01-01

    The National Bureau of Standards, in conjunction with the Oak Ridge National Laboratory and the Accelerator Mass Spectrometry community, is in the process of developing a beryllium isotopic solution Standard Reference Material. The master 10 Be/ 9 Be solution was characterized isotopically by resonance-ionization and secondary-ion mass-spectrometric-based techniques, and radioactivity measurements were by liquid scintillation counting. The master solution was gravimetrically diluted with 9 Be to a final 10 Be/ 9 Be atomic ratio of 3 x 10 -11 . The preliminary data indicate a half life for 10 Be of 1.3 million years, and AMS measurements are within 10% of the known beryllium isotopic ratio

  9. New Carbonate Standard Reference Materials for Boron Isotope Geochemistry

    Science.gov (United States)

    Stewart, J.; Christopher, S. J.; Day, R. D.

    2015-12-01

    The isotopic composition of boron (δ11B) in marine carbonates is well established as a proxy for past ocean pH. Yet, before palaeoceanographic interpretation can be made, rigorous assessment of analytical uncertainty of δ11B data is required; particularly in light of recent interlaboratory comparison studies that reported significant measurement disagreement between laboratories [1]. Well characterised boron standard reference materials (SRMs) in a carbonate matrix are needed to assess the accuracy and precision of carbonate δ11B measurements throughout the entire procedural chemistry; from sample cleaning, to ionic separation of boron from the carbonate matrix, and final δ11B measurement by multi-collector inductively coupled plasma mass spectrometry. To date only two carbonate reference materials exist that have been value-assigned by the boron isotope measurement community [2]; JCp-1 (porites coral) and JCt-1 (Giant Clam) [3]. The National Institute of Standards and Technology (NIST) will supplement these existing standards with new solution based inorganic carbonate boron SRMs that replicate typical foraminiferal and coral B/Ca ratios and δ11B values. These new SRMs will not only ensure quality control of full procedural chemistry between laboratories, but have the added benefits of being both in abundant supply and free from any restrictions associated with shipment of biogenic samples derived from protected species. Here we present in-house δ11B measurements of these new boron carbonate SRM solutions. These preliminary data will feed into an interlaboratory comparison study to establish certified values for these new NIST SRMs. 1. Foster, G.L., et al., Chemical Geology, 2013. 358(0): p. 1-14. 2. Gutjahr, M., et al., Boron Isotope Intercomparison Project (BIIP): Development of a new carbonate standard for stable isotopic analyses. Geophysical Research Abstracts, EGU General Assembly 2014, 2014. 16(EGU2014-5028-1). 3. Inoue, M., et al., Geostandards and

  10. Neutron activation analysis of reference materials by the k sub 0 standardization and relative methods

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, M C; Martinho, E [LNETI/ICEN, Sacavem (Portugal)

    1989-04-15

    Instrumental neutron activation analysis with the k{sub o}-standardization method was applied to eight geological, environmental and biological reference materials, including leaves, blood, fish, sediments, soils and limestone. To a first approximation, the results were normally distributed around the certified values with a standard deviation of 10%. Results obtained by using the relative method based on well characterized multi-element standards for IAEA CRM Soil-7 are reported.

  11. Determination of sampling constants in NBS geochemical standard reference materials

    International Nuclear Information System (INIS)

    Filby, R.H.; Bragg, A.E.; Grimm, C.A.

    1986-01-01

    Recently Filby et al. showed that, for several elements, National Bureau of Standards (NBS) Fly Ash standard reference material (SRM) 1633a was a suitable reference material for microanalysis (sample weights 2 , and the mean sample weight, W vector, K/sub s/ = (S/sub s/%) 2 W vector, could not be determined from these data because it was not possible to quantitate other sources of error in the experimental variances. K/sub s/ values for certified elements in geochemical SRMs provide important homogeneity information for microanalysis. For mineralogically homogeneous SRMs (i.e., small K/sub s/ values for associated elements) such as the proposed clays, it is necessary to determine K/sub s/ by analysis of very small sample aliquots to maximize the subsampling variance relative to other sources of error. This source of error and the blank correction for the sample container can be eliminated by determining K/sub s/ from radionuclide activities of weighed subsamples of a preirradiated SRM

  12. Validity and Reliability of a Glucometer Against Industry Reference Standards.

    Science.gov (United States)

    Salacinski, Amanda J; Alford, Micah; Drevets, Kathryn; Hart, Sarah; Hunt, Brian E

    2014-01-01

    As an appealing alternative to reference glucose analyzers, portable glucometers are recommended for self-monitoring at home, in the field, and in research settings. The purpose was to characterize the accuracy and precision, and bias of glucometers in biomedical research. Fifteen young (20-36 years; mean = 24.5), moderately to highly active men (n = 10) and women (n = 5), defined by exercising 2 to 3 times a week for the past 6 months, were given an oral glucose tolerance test (OGTT) after an overnight fast. Participants ingested 50, 75, or 150 grams of glucose over a 5-minute period. The glucometer was compared to a reference instrument. The glucometer had 39% of values within 15% of measurements made using the reference instrument ranging from 45.05 to 169.37 mg/dl. There was both a proportional (-0.45 to -0.39) and small fixed (5.06 and 0.90 mg/dl) bias. Results of the present study suggest that the glucometer provided poor validity and reliability results compared to the results provided by the reference laboratory analyzer. The portable glucometers should be used for patient management, but not for diagnosis, treatment, or research purposes. © 2014 Diabetes Technology Society.

  13. International Longitudinal Paediatric Reference Standards for Bone Mineral Content

    Science.gov (United States)

    Baxter-Jones, Adam DG; McKay, Heather; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don

    2014-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women’s Health Study (n=112) and Stanford’s Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement in predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (P accrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. Similar findings were found for PF and FN. Female models for all sites were similar with age, height and weight all independent significant predictors of BMC accrual (P accounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in paediatrics we recommend standards that are sex, age, size and ethnic specific. PMID:19854308

  14. International longitudinal pediatric reference standards for bone mineral content.

    Science.gov (United States)

    Baxter-Jones, Adam D G; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don; McKay, Heather

    2010-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site-specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women's Health Study (n=112) and Stanford's Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement between predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (Paccrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. We report similar findings for the PF and FN. Models for females for all sites were similar with age, height and weight as independent significant predictors of BMC accrual (Paccounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in pediatrics we recommend standards that are sex, age, size and ethnic specific. Copyright (c) 2009 Elsevier Inc. All rights reserved.

  15. Improving the efficiency of quantitative (1)H NMR: an innovative external standard-internal reference approach.

    Science.gov (United States)

    Huang, Yande; Su, Bao-Ning; Ye, Qingmei; Palaniswamy, Venkatapuram A; Bolgar, Mark S; Raglione, Thomas V

    2014-01-01

    The classical internal standard quantitative NMR (qNMR) method determines the purity of an analyte by the determination of a solution containing the analyte and a standard. Therefore, the standard must meet the requirements of chemical compatibility and lack of resonance interference with the analyte as well as a known purity. The identification of such a standard can be time consuming and must be repeated for each analyte. In contrast, the external standard qNMR method utilizes a standard with a known purity to calibrate the NMR instrument. The external standard and the analyte are measured separately, thereby eliminating the matter of chemical compatibility and resonance interference between the standard and the analyte. However, the instrumental factors, including the quality of NMR tubes, must be kept the same. Any deviations will compromise the accuracy of the results. An innovative qNMR method reported herein utilizes an internal reference substance along with an external standard to assume the role of the standard used in the traditional internal standard qNMR method. In this new method, the internal reference substance must only be chemically compatible and be free of resonance-interference with the analyte or external standard whereas the external standard must only be of a known purity. The exact purity or concentration of the internal reference substance is not required as long as the same quantity is added to the external standard and the analyte. The new method reduces the burden of searching for an appropriate standard for each analyte significantly. Therefore the efficiency of the qNMR purity assay increases while the precision of the internal standard method is retained. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Hg0 and HgCl2 Reference Gas Standards: ?NIST Traceability ...

    Science.gov (United States)

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the true concentrations of Hg0 and HgCl2 reference gases produced from high quality, NIST-traceable, commercial Hg0 and HgCl2 generators. This presentation will also discuss the availability of HCl and Hg0 compressed reference gas standards as a result of EPA's recently approved Alternative Methods 114 and 118. Gaseous elemental mercury (Hg0) and oxidized mercury (HgCl2) reference standards are integral to the use of mercury continuous emissions monitoring systems (Hg CEMS) for regulatory compliance emissions monitoring. However, a quantitative disparity of approximately 7-10% has been observed between commercial Hg0 and HgCl2 reference gases which currently limits the use of (HgCl2) reference gas standards. Resolving this disparity would enable the expanded use of (HgCl2) reference gas standards for regulatory compliance purposes.

  17. A Comparative Study of Standardized Infinity Reference and Average Reference for EEG of Three Typical Brain States

    Directory of Open Access Journals (Sweden)

    Gaoxing Zheng

    2018-03-01

    Full Text Available The choice of different reference electrodes plays an important role in deciphering the functional meaning of electroencephalography (EEG signals. In recent years, the infinity zero reference using the reference electrode standard technique (REST has been increasingly applied, while the average reference (AR was generally advocated as the best available reference option in previous classical EEG studies. Here, we designed EEG experiments and performed a direct comparison between the influences of REST and AR on EEG-revealed brain activity features for three typical brain behavior states (eyes-closed, eyes-open and music-listening. The analysis results revealed the following observations: (1 there is no significant difference in the alpha-wave-blocking effect during the eyes-open state compared with the eyes-closed state for both REST and AR references; (2 there was clear frontal EEG asymmetry during the resting state, and the degree of lateralization under REST was higher than that under AR; (3 the global brain functional connectivity density (FCD and local FCD have higher values for REST than for AR under different behavior states; and (4 the value of the small-world network characteristic in the eyes-closed state is significantly (in full, alpha, beta and gamma frequency bands higher than that in the eyes-open state, and the small-world effect under the REST reference is higher than that under AR. In addition, the music-listening state has a higher small-world network effect than the eyes-closed state. The above results suggest that typical EEG features might be more clearly presented by applying the REST reference than by applying AR when using a 64-channel recording.

  18. Reference values and evaluation of the results of intercomparisons

    International Nuclear Information System (INIS)

    Aigner, H.; Deron, S.; Kuhn, E.

    1981-01-01

    The need of a reference value for the composition of materials distributed in intercomparisons is generally recognized. A single reference laboratory or a group of reference laboratories may be used to establish this reference value. The respective advantages and limitations of the two approaches are discussed. The reference measurements must be evaluated to provide the confidence limits of the reference value but also an estimate of the possible heterogeneity of the materials and its samples. The results of the intercomparison measurements should themselves be evaluated to test and discuss the significance of the biases of individual and selected groups of laboratories or techniques. The approach taken by the Analytical Quality Control Services of the International Atomic Energy Agency is illustrated by the SR-1 intercomparison on uranium assay in UO 2 powder

  19. Value assignment of nutrient concentrations in five standard reference materials and six reference materials.

    Science.gov (United States)

    Sharpless, K E; Gill, L M

    2000-01-01

    A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of

  20. 76 FR 8989 - Federal Acquisition Regulation; Updated Financial Accounting Standards Board Accounting References

    Science.gov (United States)

    2011-02-16

    ... Acquisition Regulation; Updated Financial Accounting Standards Board Accounting References AGENCIES... Acquisition Regulation (FAR) to update references to authoritative accounting standards owing to the Financial... Accounting Principles (GAAP) (``Codification of GAAP''). DATES: Interested parties should submit written...

  1. Determination of multielement in optical waveguide and standard reference materials by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Kobayashi, K.; Kudo, K.

    1979-01-01

    Trace amounts of transition elements (Co, Cr, Cu, Fe, Mn and V) and other seven elements in optical waveguide samples were determined by INAA. The contents of impurities in ultre-pure materials are less than those of high-purity materials and of G.R. grade. The increase of contamination of trace transition elements and iridium from furnace or crucible are observed in the production of optical glass fibers. Up to seventeen elements were determined in five NBS biological standard reference materials: Oyster Tissue: SRM-1566, Brewers Yeast: SRM-1569, Spinach: SRM-1570, Orchard Leaves: SRM-1571 and Tuna Fish, and in four Japanese biological standard reference materials: Tea Leaves B and C, Pepperbush and Shark Meat. The analytical results in NBS and Japanese standard reference materials are in good agreement with published values and certified values by NBS. (author)

  2. The use of high accuracy NAA for the certification of NIST botanical standard reference materials

    International Nuclear Information System (INIS)

    Becker, D.A.; Greenberg, R.R.; Stone, S.F.

    1992-01-01

    Neutron activation analysis is one of many analytical techniques used at the National Institute of Standards and Technology (NIST) for the certification of NIST Standard Reference Materials (SRMs). NAA competes favorably with all other techniques because of it's unique capabilities for high accuracy even at very low concentrations for many elements. In this paper, instrumental and radiochemical NAA results are described for 25 elements in two new NIST SRMs, SRM 1515 (Apple Leaves) and SRM 1547 (Peach Leaves), and are compared to the certified values for 19 elements in these two new botanical reference materials. (author) 7 refs.; 4 tabs

  3. Initial testing of a neutron activation analysis system by analysing standard reference materials

    International Nuclear Information System (INIS)

    Suhaimi Hamzah; Roslan Idris; Abdul Khalik Haji Wood; Che Seman Mahmood; Abdul Rahim Mohamad Noor.

    1983-01-01

    This paper describes the data acquisition and processing system in our laboratories (ND6600), the methods of activation analysis and the results obtained from our analysis of IAEA standard reference material (SL-l lake sediments and NBS coal ash 1632a). These standards were analysed in order to check the capability of the system, which was designed in such a way as to enable the user to independently collect and process data from multiple radiation detectors. (author)

  4. Evaluation of a new 10 mA DC current reference standard

    CERN Document Server

    Fernqvist, G; Power, F

    2002-01-01

    A new DC current reference standard has been developed as a component in a Current calibration hierarchy in the LHC project at CERN. The standard provides 10 mA DC current with an accuracy less than 0.5 ppm, drift less than 2 ppm/year and compliance error less than 0.1 ppm for 0-10 V. The paper gives the results from two years evaluation of a series of 5 units.

  5. Iodine in different food articles and standard reference materials

    International Nuclear Information System (INIS)

    Dermelj, M.; Slejkovec, Z.; Byrne, A.R.; Stegnar, P.; Stibilj, V.; Rossbach, M.

    1990-01-01

    The greater part of essential iodine enters living organisms via the food chain. Nevertheless, quantitative data on its concentration in diets, food articles and also in available SRMs are very poor and scarce. This and WHO recommendations on daily allowances of iodine for man via food articles caused an added demand for accurate and reliable determination of iodine in these samples. From this point of view the purpose of the present was to analyse and to establish the concentration levels of total iodine in some food articles, diets, SRMs and candidate reference materials by the use of rapid radiochemical separation, developed in our laboratory. The results were checked by the analysis of SRMs with available certified values for iodine and good agreement is evident. (orig.)

  6. A Standardized Reference Data Set for Vertebrate Taxon Name Resolution.

    Science.gov (United States)

    Zermoglio, Paula F; Guralnick, Robert P; Wieczorek, John R

    2016-01-01

    Taxonomic names associated with digitized biocollections labels have flooded into repositories such as GBIF, iDigBio and VertNet. The names on these labels are often misspelled, out of date, or present other problems, as they were often captured only once during accessioning of specimens, or have a history of label changes without clear provenance. Before records are reliably usable in research, it is critical that these issues be addressed. However, still missing is an assessment of the scope of the problem, the effort needed to solve it, and a way to improve effectiveness of tools developed to aid the process. We present a carefully human-vetted analysis of 1000 verbatim scientific names taken at random from those published via the data aggregator VertNet, providing the first rigorously reviewed, reference validation data set. In addition to characterizing formatting problems, human vetting focused on detecting misspelling, synonymy, and the incorrect use of Darwin Core. Our results reveal a sobering view of the challenge ahead, as less than 47% of name strings were found to be currently valid. More optimistically, nearly 97% of name combinations could be resolved to a currently valid name, suggesting that computer-aided approaches may provide feasible means to improve digitized content. Finally, we associated names back to biocollections records and fit logistic models to test potential drivers of issues. A set of candidate variables (geographic region, year collected, higher-level clade, and the institutional digitally accessible data volume) and their 2-way interactions all predict the probability of records having taxon name issues, based on model selection approaches. We strongly encourage further experiments to use this reference data set as a means to compare automated or computer-aided taxon name tools for their ability to resolve and improve the existing wealth of legacy data.

  7. A Standardized Reference Data Set for Vertebrate Taxon Name Resolution.

    Directory of Open Access Journals (Sweden)

    Paula F Zermoglio

    Full Text Available Taxonomic names associated with digitized biocollections labels have flooded into repositories such as GBIF, iDigBio and VertNet. The names on these labels are often misspelled, out of date, or present other problems, as they were often captured only once during accessioning of specimens, or have a history of label changes without clear provenance. Before records are reliably usable in research, it is critical that these issues be addressed. However, still missing is an assessment of the scope of the problem, the effort needed to solve it, and a way to improve effectiveness of tools developed to aid the process. We present a carefully human-vetted analysis of 1000 verbatim scientific names taken at random from those published via the data aggregator VertNet, providing the first rigorously reviewed, reference validation data set. In addition to characterizing formatting problems, human vetting focused on detecting misspelling, synonymy, and the incorrect use of Darwin Core. Our results reveal a sobering view of the challenge ahead, as less than 47% of name strings were found to be currently valid. More optimistically, nearly 97% of name combinations could be resolved to a currently valid name, suggesting that computer-aided approaches may provide feasible means to improve digitized content. Finally, we associated names back to biocollections records and fit logistic models to test potential drivers of issues. A set of candidate variables (geographic region, year collected, higher-level clade, and the institutional digitally accessible data volume and their 2-way interactions all predict the probability of records having taxon name issues, based on model selection approaches. We strongly encourage further experiments to use this reference data set as a means to compare automated or computer-aided taxon name tools for their ability to resolve and improve the existing wealth of legacy data.

  8. A Framework for Establishing Standard Reference Scale of Texture by Multivariate Statistical Analysis Based on Instrumental Measurement and Sensory Evaluation.

    Science.gov (United States)

    Zhi, Ruicong; Zhao, Lei; Xie, Nan; Wang, Houyin; Shi, Bolin; Shi, Jingye

    2016-01-13

    A framework of establishing standard reference scale (texture) is proposed by multivariate statistical analysis according to instrumental measurement and sensory evaluation. Multivariate statistical analysis is conducted to rapidly select typical reference samples with characteristics of universality, representativeness, stability, substitutability, and traceability. The reasonableness of the framework method is verified by establishing standard reference scale of texture attribute (hardness) with Chinese well-known food. More than 100 food products in 16 categories were tested using instrumental measurement (TPA test), and the result was analyzed with clustering analysis, principal component analysis, relative standard deviation, and analysis of variance. As a result, nine kinds of foods were determined to construct the hardness standard reference scale. The results indicate that the regression coefficient between the estimated sensory value and the instrumentally measured value is significant (R(2) = 0.9765), which fits well with Stevens's theory. The research provides reliable a theoretical basis and practical guide for quantitative standard reference scale establishment on food texture characteristics.

  9. Measurement standards and the general problem of reference points in chemical analysis

    International Nuclear Information System (INIS)

    Richter, W.; Dube, G.

    2002-01-01

    Besides the measurement standards available in general metrology in the form of the realisations of the units of measurement, measurement standards of chemical composition are needed for the vast field of chemical measurement (measurements of the chemical composition), because it is the main aim of such measurements to quantify non-isolated substances, often in complicated matrices, to which the 'classical' measurement standards and their lower- level derivatives are not directly applicable. At present, material artefacts as well as standard measurement devices serve as chemical measurement standards. These are measurement standards in the full metrological sense only, however, if they are firmly linked to the SI unit in which the composition represented by the standard is expressed. This requirement has the consequence that only a very restricted number of really reliable chemical measurement standards exist at present. Since it is very difficult and time consuming to increase this number substantially and, on the other hand, reliable reference points are increasingly needed for all kinds of chemical measurements, primary methods of measurement and high-level reference measurements will play an increasingly important role for the establishment of worldwide comparability and hence mutual acceptance of chemical measurement results. (author)

  10. Reference design for the standard mirror hybrid reactor

    Energy Technology Data Exchange (ETDEWEB)

    Bender, D.J.; Fink, J.H.; Galloway, T.R.; Kastenberg, W.E.; Lee, J.D.; Devoto, R.S.; Neef, W.S. Jr.; Schultz, K.R.; Culver, D.W.; Rao, S.B.; Rao, S.R.

    1978-05-22

    This report describes the results of a two-year study by Lawrence Livermore Laboratory and General Atomic Co. to develop a conceptual design for the standard (minimum-B) mirror hybrid reactor. The reactor parameters have been chosen to minimize the cost of producing nuclear fuel (/sup 239/Pu) for consumption in fission power reactors (light water reactors). The deuterium-tritium plasma produces approximately 400 MW of fusion power with a plasma Q of 0.64. The fast-fission blanket, which is fueled with depleted uranium and lithium, generates sufficient tritium to run the reactor, has a blanket energy multiplication of M = 10.4, and has a net fissile breeding ratio of Pu/n = 1.51. The reactor has a net electrical output of 600 MWe, a fissile production of 2000 kg of plutonium per year (at a capacity factor of 0.74), and a net plant efficiency of 0.18. The plasma-containment field is generated by a Yin-Yang magnet using NbTi superconductor, and the neutral beam system uses positive-ion acceleration with beam direct conversion. The spherical blanket is based on gas-cooled fast reactor technology. The fusion components, blanket, and primary heat-transfer loop components are all contained within a prestressed-concrete reactor vessel, which provides magnet restraint and supports the primary heat-transfer loop and the blanket.

  11. Reference design for the standard mirror hybrid reactor

    International Nuclear Information System (INIS)

    Bender, D.J.; Fink, J.H.; Galloway, T.R.; Kastenberg, W.E.; Lee, J.D.; Devoto, R.S.; Neef, W.S. Jr.; Schultz, K.R.; Culver, D.W.; Rao, S.B.; Rao, S.R.

    1978-01-01

    This report describes the results of a two-year study by Lawrence Livermore Laboratory and General Atomic Co. to develop a conceptual design for the standard (minimum-B) mirror hybrid reactor. The reactor parameters have been chosen to minimize the cost of producing nuclear fuel ( 239 Pu) for consumption in fission power reactors (light water reactors). The deuterium-tritium plasma produces approximately 400 MW of fusion power with a plasma Q of 0.64. The fast-fission blanket, which is fueled with depleted uranium and lithium, generates sufficient tritium to run the reactor, has a blanket energy multiplication of M = 10.4, and has a net fissile breeding ratio of Pu/n = 1.51. The reactor has a net electrical output of 600 MWe, a fissile production of 2000 kg of plutonium per year (at a capacity factor of 0.74), and a net plant efficiency of 0.18. The plasma-containment field is generated by a Yin-Yang magnet using NbTi superconductor, and the neutral beam system uses positive-ion acceleration with beam direct conversion. The spherical blanket is based on gas-cooled fast reactor technology. The fusion components, blanket, and primary heat-transfer loop components are all contained within a prestressed-concrete reactor vessel, which provides magnet restraint and supports the primary heat-transfer loop and the blanket

  12. 28 CFR 45.1 - Cross-reference to ethical standards and financial disclosure regulations.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Cross-reference to ethical standards and...) EMPLOYEE RESPONSIBILITIES § 45.1 Cross-reference to ethical standards and financial disclosure regulations. Employees of the Department of Justice are subject to the executive branch-wide Standards of Ethical Conduct...

  13. CMS standard model Higgs boson results

    Directory of Open Access Journals (Sweden)

    Garcia-Abia Pablo

    2013-11-01

    Full Text Available In July 2012 CMS announced the discovery of a new boson with properties resembling those of the long-sought Higgs boson. The analysis of the proton-proton collision data recorded by the CMS detector at the LHC, corresponding to integrated luminosities of 5.1 fb−1 at √s = 7 TeV and 19.6 fb−1 at √s = 8 TeV, confirm the Higgs-like nature of the new boson, with a signal strength associated with vector bosons and fermions consistent with the expectations for a standard model (SM Higgs boson, and spin-parity clearly favouring the scalar nature of the new boson. In this note I review the updated results of the CMS experiment.

  14. Standard Relativistic Reference Systems and the IAU Framework

    Science.gov (United States)

    Soffel, Michael H.

    2009-05-01

    The classical post-Newtonian (PN) framework is formulated in one single reference system. In a series of papers Damour, Soffel and Xu laid the foundations for a new improved PN framework dealing with the celestial mechanical problem of N gravitationally interacting rotating bodies of arbitrary shape and the problem of astronomical reference systems. In the DSX-framework a total of N+1 reference systems with corresponding coordinates is introduced in the N-body problem: a global one covering the entire model manifold where the translational equations of motion are formulated and one local system attached to each of the N bodies that is co-moving with the body under consideration. In each of these systems the metric tensor is assumed to be of a special form determined by two potentials: a scalar and a vector potential. Theorems are given for the transformations between local and global coordinates and metric potentials. In each of the local systems outside the local body the metric potentials are expressed in terms of Blanchet-Damour mass- and spin-multipole moments. The talk first introduces the original DSX formalism and then concentrates on IAU resolutions related with it. Finally, the formalism is extended to include also effects from the cosmic expansion. The influence of the Hubble expansion on the dynamics of the solar system is explicitly discussed in some detail.

  15. [Application of traditional Chinese medicine reference standards in quality control of Chinese herbal pieces].

    Science.gov (United States)

    Lu, Tu-Lin; Li, Jin-Ci; Yu, Jiang-Yong; Cai, Bao-Chang; Mao, Chun-Qin; Yin, Fang-Zhou

    2014-01-01

    Traditional Chinese medicine (TCM) reference standards plays an important role in the quality control of Chinese herbal pieces. This paper overviewed the development of TCM reference standards. By analyzing the 2010 edition of Chinese pharmacopoeia, the application of TCM reference standards in the quality control of Chinese herbal pieces was summarized, and the problems exiting in the system were put forward. In the process of improving the quality control level of Chinese herbal pieces, various kinds of advanced methods and technology should be used to research the characteristic reference standards of Chinese herbal pieces, more and more reasonable reference standards should be introduced in the quality control system of Chinese herbal pieces. This article discussed the solutions in the aspect of TCM reference standards, and future development of quality control on Chinese herbal pieces is prospected.

  16. New International Reference Standards of Voltage and Resistance.

    Science.gov (United States)

    Sirvastava, V. P.

    1991-01-01

    The introduction of the quantum standards of resistance and voltage, based on the Quantum Hall Effect (QHE) and the Josephson Effect, can be used to establish highly reproducible and uniform representations of the ohm and volt worldwide. Discussed are the QHE and the Josephson Effect. (KR)

  17. Platinum stable isotope analysis of geological standard reference materials by double-spike MC-ICPMS

    DEFF Research Database (Denmark)

    Creech, John Benjamin; Baker, J. A.; Handler, M. R.

    2014-01-01

    . Double-spiking of samples was carried out prior to digestion and chemical separation to correct for any mass-dependent fractionation that may occur due to incomplete recovery of Pt. Samples were digested using a NiS fire assay method, which pre-concentrates Pt into a metallic bead that is readily...... metal standard solution doped with a range of synthetic matrices and results in Pt yields of ≥90% with purity of ≥95%. Using this chemical separation technique, we have separated Pt from 11 international geological standard reference materials comprising of PGE ores, mantle rocks, igneous rocks and one...

  18. Measuring the activity of BioBrick promoters using an in vivo reference standard

    Directory of Open Access Journals (Sweden)

    Kelly Jason R

    2009-03-01

    Full Text Available Abstract Background The engineering of many-component, synthetic biological systems is being made easier by the development of collections of reusable, standard biological parts. However, the complexity of biology makes it difficult to predict the extent to which such efforts will succeed. As a first practical example, the Registry of Standard Biological Parts started at MIT now maintains and distributes thousands of BioBrick™ standard biological parts. However, BioBrick parts are only standardized in terms of how individual parts are physically assembled into multi-component systems, and most parts remain uncharacterized. Standardized tools, techniques, and units of measurement are needed to facilitate the characterization and reuse of parts by independent researchers across many laboratories. Results We found that the absolute activity of BioBrick promoters varies across experimental conditions and measurement instruments. We choose one promoter (BBa_J23101 to serve as an in vivo reference standard for promoter activity. We demonstrated that, by measuring the activity of promoters relative to BBa_J23101, we could reduce variation in reported promoter activity due to differences in test conditions and measurement instruments by ~50%. We defined a Relative Promoter Unit (RPU in order to report promoter characterization data in compatible units and developed a measurement kit so that researchers might more easily adopt RPU as a standard unit for reporting promoter activity. We distributed a set of test promoters to multiple labs and found good agreement in the reported relative activities of promoters so measured. We also characterized the relative activities of a reference collection of BioBrick promoters in order to further support adoption of RPU-based measurement standards. Conclusion Relative activity measurements based on an in vivoreference standard enables improved measurement of promoter activity given variation in measurement

  19. Physical Fitness Reference Standards in French Youth: The BOUGE Program.

    Science.gov (United States)

    Vanhelst, Jérémy; Labreuche, Julien; Béghin, Laurent; Drumez, Elodie; Fardy, Paul S; Chapelot, Didier; Mikulovic, Jacques; Ulmer, Zékya

    2017-06-01

    The aim of this study was to establish sex- and age-specific physical fitness percentiles in French youth. A sample of 11,186 children and adolescents (5,546 boys and 5,640 girls), aged between 10 and 15 years, was assessed in the French national BOUGE study. Participants were tested for their cardiorespiratory fitness, muscular endurance, speed, flexibility, and agility using the following tests: 20-m shuttle run tests, curl-ups test, 50-m sprint test, back-saver sit and reach test, and 10 × 5-m shuttle run test. Percentile values were estimated for French youth as a function of age stratified by sex using the generalized additive model for location, scale, and shape (GAMLSS). In general, physical fitness was better in boys than in girls, except for the back-saver sit and reach test, in which girls performed better. Except for the back-saver sit and reach test and 10 × 5-m shuttle run test, physical fitness performance was significantly associated with age. Sex- and age-specific normative values for physical fitness tests in French youth expressed as percentiles from the fifth to the 95th are provided. Reference values provide normative data for French youth. The data are useful in identifying special needs for appropriate intervention programs.

  20. Semi-automatic construction of reference standards for evaluation of image registration

    NARCIS (Netherlands)

    Murphy, K.; Ginneken, van B.; Klein, S.; Staring, M.; Hoop, de B.J.; Viergever, M.A.; Pluim, J.P.W.

    2011-01-01

    Quantitative evaluation of image registration algorithms is a difficult and under-addressed issue due to the lack of a reference standard in most registration problems. In this work a method is presented whereby detailed reference standard data may be constructed in an efficient semi-automatic

  1. MATLAB Toolboxes for Reference Electrode Standardization Technique (REST) of Scalp EEG.

    Science.gov (United States)

    Dong, Li; Li, Fali; Liu, Qiang; Wen, Xin; Lai, Yongxiu; Xu, Peng; Yao, Dezhong

    2017-01-01

    Reference electrode standardization technique (REST) has been increasingly acknowledged and applied as a re-reference technique to transform an actual multi-channels recordings to approximately zero reference ones in electroencephalography/event-related potentials (EEG/ERPs) community around the world in recent years. However, a more easy-to-use toolbox for re-referencing scalp EEG data to zero reference is still lacking. Here, we have therefore developed two open-source MATLAB toolboxes for REST of scalp EEG. One version of REST is closely integrated into EEGLAB, which is a popular MATLAB toolbox for processing the EEG data; and another is a batch version to make it more convenient and efficient for experienced users. Both of them are designed to provide an easy-to-use for novice researchers and flexibility for experienced researchers. All versions of the REST toolboxes can be freely downloaded at http://www.neuro.uestc.edu.cn/rest/Down.html, and the detailed information including publications, comments and documents on REST can also be found from this website. An example of usage is given with comparative results of REST and average reference. We hope these user-friendly REST toolboxes could make the relatively novel technique of REST easier to study, especially for applications in various EEG studies.

  2. Standard Test Method for Calibration of Non-Concentrator Photovoltaic Secondary Reference Cells

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers calibration and characterization of secondary terrestrial photovoltaic reference cells to a desired reference spectral irradiance distribution. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of a photovoltaic device. 1.2 Secondary reference cells are calibrated indoors using simulated sunlight or outdoors in natural sunlight by reference to a primary reference cell previously calibrated to the same desired reference spectral irradiance distribution. 1.3 Secondary reference cells calibrated according to this test method will have the same radiometric traceability as the of the primary reference cell used for the calibration. Therefore, if the primary reference cell is traceable to the World Radiometric Reference (WRR, see Test Method E816), the resulting secondary reference cell will also be traceable to the WRR. 1.4 This test method appli...

  3. Comparison Between a Reference Torque Standard Machine and a Deadweight Torque Standard Machine to BE Used in Torque Calibration

    Science.gov (United States)

    Meng, Feng; Zhang, Zhimin; Lin, Jing

    The paper describes the reference torque standard machine with high accuracy and multifunction, developed by our institute, and introduces the structure and working principle of this machine. It has three main functions. The first function is the hydraulic torque wrench calibration function. The second function is torque multiply calibration function. The third function is reference torque standard machine function. We can calibrate the torque multipliers, hydraulic wrenches and transducers by this machine. A comparison experiment has been done between this machine and a deadweight torque standard machine. The consistency between the 30 kNm reference torque machine and the 2000 Nm dead-weight torque standard machine under the claimed uncertainties was verified.

  4. 18 CFR 1300.101 - Cross references to employee ethical conduct standards and other applicable regulations.

    Science.gov (United States)

    2010-04-01

    ... employee ethical conduct standards and other applicable regulations. 1300.101 Section 1300.101 Conservation... TENNESSEE VALLEY AUTHORITY § 1300.101 Cross references to employee ethical conduct standards and other...-wide standards of ethical conduct at 5 CFR part 2635 and to the TVA regulations at 5 CFR part 7901...

  5. Reference results for time-like evolution up to

    Science.gov (United States)

    Bertone, Valerio; Carrazza, Stefano; Nocera, Emanuele R.

    2015-03-01

    We present high-precision numerical results for time-like Dokshitzer-Gribov-Lipatov-Altarelli-Parisi evolution in the factorisation scheme, for the first time up to next-to-next-to-leading order accuracy in quantum chromodynamics. First, we scrutinise the analytical expressions of the splitting functions available in the literature, in both x and N space, and check their mutual consistency. Second, we implement time-like evolution in two publicly available, entirely independent and conceptually different numerical codes, in x and N space respectively: the already existing APFEL code, which has been updated with time-like evolution, and the new MELA code, which has been specifically developed to perform the study in this work. Third, by means of a model for fragmentation functions, we provide results for the evolution in different factorisation schemes, for different ratios between renormalisation and factorisation scales and at different final scales. Our results are collected in the format of benchmark tables, which could be used as a reference for global determinations of fragmentation functions in the future.

  6. Setting the standard: The IAEA safety standards set the global reference

    International Nuclear Information System (INIS)

    Williams, L.

    2003-01-01

    For the IAEA, setting and promoting standards for nuclear radiation, waste, and transport safety have been priorities from the start, rooted in the Agency's 1957 Statute. Today, a corpus of international standards are in place that national regulators and industries in many countries are applying, and more are being encouraged and assisted to follow them. Considerable work is done to keep safety standards updated and authoritative. They cover five main areas: the safety of nuclear facilities; radiation protection and safety of radiation sources; safe management of radioactive waste; safe transport of radioactive material; and thematic safety areas, such as emergency preparedness or legal infrastructures. Overall, the safety standards reflect an international consensus on what constitutes a high level of safety for protecting people and the environment. All IAEA Member States can nominate experts for the Agency standards committees and provide comments on draft standards. Through this ongoing cycle of review and feedback, the standards are refined, updated, and extended where needed

  7. From plastic to gold: a unified classification scheme for reference standards in medical image processing

    Science.gov (United States)

    Lehmann, Thomas M.

    2002-05-01

    Reliable evaluation of medical image processing is of major importance for routine applications. Nonetheless, evaluation is often omitted or methodically defective when novel approaches or algorithms are introduced. Adopted from medical diagnosis, we define the following criteria to classify reference standards: 1. Reliance, if the generation or capturing of test images for evaluation follows an exactly determined and reproducible protocol. 2. Equivalence, if the image material or relationships considered within an algorithmic reference standard equal real-life data with respect to structure, noise, or other parameters of importance. 3. Independence, if any reference standard relies on a different procedure than that to be evaluated, or on other images or image modalities than that used routinely. This criterion bans the simultaneous use of one image for both, training and test phase. 4. Relevance, if the algorithm to be evaluated is self-reproducible. If random parameters or optimization strategies are applied, reliability of the algorithm must be shown before the reference standard is applied for evaluation. 5. Significance, if the number of reference standard images that are used for evaluation is sufficient large to enable statistically founded analysis. We demand that a true gold standard must satisfy the Criteria 1 to 3. Any standard only satisfying two criteria, i.e., Criterion 1 and Criterion 2 or Criterion 1 and Criterion 3, is referred to as silver standard. Other standards are termed to be from plastic. Before exhaustive evaluation based on gold or silver standards is performed, its relevance must be shown (Criterion 4) and sufficient tests must be carried out to found statistical analysis (Criterion 5). In this paper, examples are given for each class of reference standards.

  8. Calibrating NIST SRM 683 as A New International Reference Standard for Zn Isotopes

    Science.gov (United States)

    Yang, Y.; Zhang, X.; Yu, H.; Huang, F.

    2017-12-01

    Zinc isotopes have been widely applied in the cosmochemical, geochemical, and environmental studies (Moynier et al. 2017). Obtaining precise Zn isotopic data for inter-laboratory comparison is a prerequisite to these applications. Currently, the JMC3-0749L is the primary reference standard for Zn isotopes (Albarède 2004), but it is not commercially available now. Thus, it is necessary to calibrate a new international primary reference standard for Zn isotopic analysis. Chen et al. (2016) showed that NIST SRM 683 (a pure Zn metal nugget of 140 grams) has a δ66ZnJMC of 0.12‰, which is falling within the range of natural Zn isotopic compositions, and it may a good candidate for the next generation of international reference standard (Chen et al. 2016). In order to further examine whether NIST SRM 683 has a homogeneous Zn isotopic composition, we measured more NIST SRM 683 by double-spike methods using MC-ICPMS (Conway et al. 2013). The metal nuggets of NIST SRM 683 were intensively sampled by micro-drilling. Zinc isotope analyses for two nuggets show that they have δ66Zn of 0.14 ± 0.02‰ (2SD, N = 32) and 0.13 ± 0.02‰ (2SD, N = 33), respectively. These values are similar to those of two Zn metal nuggets (0.11 ± 0.02‰ vs. 0.12 ± 0.02‰) reported previously by Chen et al. (2016). We fully dissolved one nugget, producing pure Zn solution with identical Zn isotopic composition with the drilling samples. All results strongly support that NIST SRM 683 is homogeneous in Zn isotopic compositions which could be an ideal candidate for the next reference for Zn isotopes. Tests on more metal nuggets will be performed in a few months for further confirming the Zn isotope compositions and homogeneity. Reference: Albarède et al., 2004. 'The stable isotope geochemistry of copper and zinc', Reviews in Mineralogy and Geochemistry, 55: 409-27. Chen et al., 2016. 'Zinc Isotopic Compositions of NIST SRM 683 and Whole-Rock Reference Materials', Geostandards and

  9. Development of saw palmetto (Serenoa repens) fruit and extract standard reference materials.

    Science.gov (United States)

    Schantz, Michele M; Bedner, Mary; Long, Stephen E; Molloy, John L; Murphy, Karen E; Porter, Barbara J; Putzbach, Karsten; Rimmer, Catherine A; Sander, Lane C; Sharpless, Katherine E; Thomas, Jeanice B; Wise, Stephen A; Wood, Laura J; Yen, James H; Yarita, Takashi; NguyenPho, Agnes; Sorenson, Wendy R; Betz, Joseph M

    2008-10-01

    As part of a collaboration with the National Institutes of Health's Office of Dietary Supplements and the Food and Drug Administration's Center for Drug Evaluation and Research, the National Institute of Standards and Technology has developed two standard reference materials (SRMs) representing different forms of saw palmetto (Serenoa repens), SRM 3250 Serenoa repens fruit and SRM 3251 Serenoa repens extract. Both of these SRMs have been characterized for their fatty acid and phytosterol content. The fatty acid concentration values are based on results from gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC/MS) analysis while the sterol concentration values are based on results from GC-FID and liquid chromatography with mass spectrometry analysis. In addition, SRM 3250 has been characterized for lead content, and SRM 3251 has been characterized for the content of beta-carotene and tocopherols. SRM 3250 (fruit) has certified concentration values for three phytosterols, 14 fatty acids as triglycerides, and lead along with reference concentration values for four fatty acids as triglycerides and 16 free fatty acids. SRM 3251 (extract) has certified concentration values for three phytosterols, 17 fatty acids as triglycerides, beta-carotene, and gamma-tocopherol along with reference concentration values for three fatty acids as triglycerides, 17 fatty acids as free fatty acids, beta-carotene isomers, and delta-tocopherol and information values for two phytosterols. These SRMs will complement other reference materials currently available with concentrations for similar analytes and are part of a series of SRMs being developed for dietary supplements.

  10. The 3D Reference Earth Model: Status and Preliminary Results

    Science.gov (United States)

    Moulik, P.; Lekic, V.; Romanowicz, B. A.

    2017-12-01

    In the 20th century, seismologists constructed models of how average physical properties (e.g. density, rigidity, compressibility, anisotropy) vary with depth in the Earth's interior. These one-dimensional (1D) reference Earth models (e.g. PREM) have proven indispensable in earthquake location, imaging of interior structure, understanding material properties under extreme conditions, and as a reference in other fields, such as particle physics and astronomy. Over the past three decades, new datasets motivated more sophisticated efforts that yielded models of how properties vary both laterally and with depth in the Earth's interior. Though these three-dimensional (3D) models exhibit compelling similarities at large scales, differences in the methodology, representation of structure, and dataset upon which they are based, have prevented the creation of 3D community reference models. As part of the REM-3D project, we are compiling and reconciling reference seismic datasets of body wave travel-time measurements, fundamental mode and overtone surface wave dispersion measurements, and normal mode frequencies and splitting functions. These reference datasets are being inverted for a long-wavelength, 3D reference Earth model that describes the robust long-wavelength features of mantle heterogeneity. As a community reference model with fully quantified uncertainties and tradeoffs and an associated publically available dataset, REM-3D will facilitate Earth imaging studies, earthquake characterization, inferences on temperature and composition in the deep interior, and be of improved utility to emerging scientific endeavors, such as neutrino geoscience. Here, we summarize progress made in the construction of the reference long period dataset and present a preliminary version of REM-3D in the upper-mantle. In order to determine the level of detail warranted for inclusion in REM-3D, we analyze the spectrum of discrepancies between models inverted with different subsets of the

  11. Cross-platform comparison of nucleic acid hybridization: toward quantitative reference standards.

    Science.gov (United States)

    Halvorsen, Ken; Agris, Paul F

    2014-11-15

    Measuring interactions between biological molecules is vitally important to both basic and applied research as well as development of pharmaceuticals. Although a wide and growing range of techniques is available to measure various kinetic and thermodynamic properties of interacting biomolecules, it can be difficult to compare data across techniques of different laboratories and personnel or even across different instruments using the same technique. Here we evaluate relevant biological interactions based on complementary DNA and RNA oligonucleotides that could be used as reference standards for many experimental systems. We measured thermodynamics of duplex formation using isothermal titration calorimetry, differential scanning calorimetry, and ultraviolet-visible (UV-vis) monitored denaturation/renaturation. These standards can be used to validate results, compare data from disparate techniques, act as a teaching tool for laboratory classes, or potentially to calibrate instruments. The RNA and DNA standards have many attractive features, including low cost, high purity, easily measurable concentrations, and minimal handling concerns, making them ideal for use as a reference material. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point

    Directory of Open Access Journals (Sweden)

    Azmil Haizam Ahmad Tarmizi

    2008-01-01

    Full Text Available This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 ° C in palm oil, 22.7 ± 0.4 ° C in palm olein and 53.4 ± 0.2 ° C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of -20 ° C, 0 ° C, 6 ° C and 24 ° C upon storage for one year.

  13. Diagnostic value of different adherence measures using electronic monitoring and virologic failure as reference standards.

    Science.gov (United States)

    Deschamps, Ann E; De Geest, Sabina; Vandamme, Anne-Mieke; Bobbaers, Herman; Peetermans, Willy E; Van Wijngaerden, Eric

    2008-09-01

    Nonadherence to antiretroviral therapy is a substantial problem in HIV and jeopardizes the success of treatment. Accurate measurement of nonadherence is therefore imperative for good clinical management but no gold standard has been agreed on yet. In a single-center prospective study nonadherence was assessed by electronic monitoring: percentage of doses missed and drug holidays and by three self reports: (1) a visual analogue scale (VAS): percentage of overall doses taken; (2) the Swiss HIV Cohort Study Adherence Questionnaire (SHCS-AQ): percentage of overall doses missed and drug holidays and (3) the European HIV Treatment Questionnaire (EHTQ): percentage of doses missed and drug holidays for each antiretroviral drug separately. Virologic failure prospectively assessed during 1 year, and electronic monitoring were used as reference standards. Using virologic failure as reference standard, the best results were for (1) the SHCS-AQ after electronic monitoring (sensitivity, 87.5%; specificity, 78.6%); (2) electronic monitoring (sensitivity, 75%; specificity, 85.6%), and (3) the VAS combined with the SHCS-AQ before electronic monitoring (sensitivity, 87.5%; specificity, 58.6%). The sensitivity of the complex EHTQ was less than 50%. Asking simple questions about doses taken or missed is more sensitive than complex questioning about each drug separately. Combining the VAS with the SHCS-AQ seems a feasible nonadherence measure for daily clinical practice. Self-reports perform better after electronic monitoring: their diagnostic value could be lower when given independently.

  14. Platinum stable isotope analysis of geological standard reference materials by double-spike MC-ICPMS.

    Science.gov (United States)

    Creech, J B; Baker, J A; Handler, M R; Bizzarro, M

    2014-01-10

    We report a method for the chemical purification of Pt from geological materials by ion-exchange chromatography for subsequent Pt stable isotope analysis by multiple-collector inductively coupled plasma mass spectrometry (MC-ICPMS) using a 196 Pt- 198 Pt double-spike to correct for instrumental mass bias. Double-spiking of samples was carried out prior to digestion and chemical separation to correct for any mass-dependent fractionation that may occur due to incomplete recovery of Pt. Samples were digested using a NiS fire assay method, which pre-concentrates Pt into a metallic bead that is readily dissolved in acid in preparation for anion-exchange chemistry. Pt was recovered from anion-exchange resin in concentrated HNO 3 acid after elution of matrix elements, including the other platinum group elements (PGE), in dilute HCl and HNO 3 acids. The separation method has been calibrated using a precious metal standard solution doped with a range of synthetic matrices and results in Pt yields of ≥90% with purity of ≥95%. Using this chemical separation technique, we have separated Pt from 11 international geological standard reference materials comprising of PGE ores, mantle rocks, igneous rocks and one sample from the Cretaceous-Paleogene boundary layer. Pt concentrations in these samples range from ca. 5 ng g -1 to 4 μg g -1 . This analytical method has been shown to have an external reproducibility on δ 198 Pt (permil difference in the 198 Pt/ 194 Pt ratio from the IRMM-010 standard) of ±0.040 (2 sd) on Pt solution standards (Creech et al., 2013, J. Anal. At. Spectrom. 28, 853-865). The reproducibility in natural samples is evaluated by processing multiple replicates of four standard reference materials, and is conservatively taken to be ca. ±0.088 (2 sd). Pt stable isotope data for the full set of reference materials have a range of δ 198 Pt values with offsets of up to 0.4‰ from the IRMM-010 standard, which are readily resolved with this technique. These

  15. Quantitative micro x-ray fluorescence analyses without reference standard material; Referenzprobenfreie quantitative Mikro-Roentgenfluoreszenzanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Wolff, Timo

    2009-07-15

    X-ray fluorescence analysis (XRF) is a standard method for non-destructive investigations. Due to the development of polycapillary optics and SDDdetectors requiring no cooling with liquid nitrogen, XRF becomes a suitable method for a large number of applications, e. g. for the analysis of objects in arts and archaeology. Spectrometers developed for those purposes allow investigations outside of laboratories und provide excitation areas with diameters of 10-70 {mu}m. In most applications, quantification of XRF data is realized by the usage of standard reference materials. Due to absorption processes in the samples the accuracy of the results depends strongly on the similarity of the sample and the reference standard. In cases where no suitable references are available, quantification can be done based on the ''fundamental parameter (fp) method''. This quantification procedure is based on a set of equations describing the fluorescence production and detection mathematical. The cross sections for the interaction of x-rays with matter can be taken from different databases. During an iteration process the element concentrations can be determined. Quantitative XRF based on fundamental parameters requires an accurate knowledge of the excitation spectrum. In case of a conventional setup this spectrum is given by the X-ray tube spectrum and can be calculated. The use of polycapillary optics in micro-XRF spectrometers changes the spectral distribution of the excitation radiation. For this reason it is necessary to access the transmission function of the used optic. The aim of this work is to find a procedure to describe this function for routine quantification based on fundamental parameters. Most of the measurements have been carried out using a commercial spectrometer developed for applications in arts and archaeology. On the one hand the parameters of the lens, used in the spectrometer, have been investigated by different experimental characterization

  16. Validation of IRDFF in 252Cf Standard and IRDF-2002 Reference Neutron Fields

    Directory of Open Access Journals (Sweden)

    Simakov Stanislav

    2016-01-01

    Full Text Available The results of validation of the latest release of International Reactor Dosimetry and Fusion File, IRDFF-1.03, in the standard 252Cf(s.f. and reference 235U(nth,f neutron benchmark fields are presented. The spectrum-averaged cross sections were shown to confirm IRDFF-1.03 in the 252Cf standard spontaneous fission spectrum; that was not the case for the current recommended spectra for 235U(nth,f. IRDFF was also validated in the spectra of the research reactor facilities ISNF, Sigma-Sigma and YAYOI, which are available in the IRDF-2002 collection. The ISNF facility was re-simulated to remove unphysical oscillations in the spectrum. IRDFF-1.03 was shown to reproduce reasonably well the spectrum-averaged data measured in these fields except for the case of YAYOI.

  17. Results of the LIRES Round Robin test on high temperature reference electrodes for LWR applications

    Energy Technology Data Exchange (ETDEWEB)

    Bosch, R.W. [SCK.CEN, Nuclear Research Centre Belgium, Boeretang 200, B-2400 Mol (Belgium); Nagy, G. [Magyar Tudomanyos Akademia KFKI Atomenergia Kutatointezet, AEKI, Konkoly Thege ut 29-33, 1121 Budapest (Hungary); Feron, D. [CEA Saclay, 91191 Gif-Sur-Yvette Cedex (France); Navas, M. [CIEMAT, Edificio 30, Dpto. Fision Nuclear, Avda. Complutense 22, 28040 Madrid, (Spain); Bogaerts, W. [KU Leuven, Kasteelpark Arenberg 31, B-3001 Leuven (Belgium); Karnik, D. [Nuclear Research Institute, NRI, Rez (Czech Republic); Dorsch, T. [Framatone ANP, Inc., Charlotte, North Carolina (United States); Molander, A. [Studsvik AB SE-611 82 Nykoeping (Sweden); Maekelae, K. [Materials and Structural Integrity, VTT Technical Research Centre of Finland, Kemistintie 3, P.O. Box 1704, FIN-02044 VTT (Finland)

    2004-07-01

    A European sponsored research project has been started on 1 October 2000 to develop high temperature reference electrodes that can be used for in-core electrochemical measurements in Light Water Reactors (LWR's). This LIRES-project (Development of Light Water Reactor Reference Electrodes) consists of 9 partners (SCK-CEN, AEKI, CEA, CIEMAT, KU Leuven, NRI Rez, Framatone ANP, Studsvik Nuclear and VTT) and will last for four years. The main objective of this LIRES project is to develop a reference electrode, which is robust enough to be used inside a LWR. Emphasize is put on the radiation hardness of both the mechanical design of the electrode as the proper functioning of the electrode. A four steps development trajectory is foreseen: (1) To set a testing standard for a Round Robin, (2) To develop different reference electrodes, (3) To perform a Round Robin test of these reference electrodes followed by selection of the best reference electrode(s), (4) To perform irradiation tests under appropriate LWR conditions in a Material Test Reactor (MTR). Four different high temperature reference electrodes have been developed and are being tested in a Round Robin test. These electrodes are: A Ceramic Membrane Electrode (CME), a Rhodium electrode, an external Ag/AgCl electrode and a Palladium electrode. The presentation will focus on the results obtained with the Round Robin test. (authors)

  18. Agreement between diagnoses reached by clinical examination and available reference standards: a prospective study of 216 patients with lumbopelvic pain

    Directory of Open Access Journals (Sweden)

    Tropp Hans

    2005-06-01

    Full Text Available Abstract Background The tissue origin of low back pain (LBP or referred lower extremity symptoms (LES may be identified in about 70% of cases using advanced imaging, discography and facet or sacroiliac joint blocks. These techniques are invasive and availability varies. A clinical examination is non-invasive and widely available but its validity is questioned. Diagnostic studies usually examine single tests in relation to single reference standards, yet in clinical practice, clinicians use multiple tests and select from a range of possible diagnoses. There is a need for studies that evaluate the diagnostic performance of clinical diagnoses against available reference standards. Methods We compared blinded clinical diagnoses with diagnoses based on available reference standards for known causes of LBP or LES such as discography, facet, sacroiliac or hip joint blocks, epidurals injections, advanced imaging studies or any combination of these tests. A prospective, blinded validity design was employed. Physiotherapists examined consecutive patients with chronic lumbopelvic pain and/or referred LES scheduled to receive the reference standard examinations. When diagnoses were in complete agreement regardless of complexity, "exact" agreement was recorded. When the clinical diagnosis was included within the reference standard diagnoses, "clinical agreement" was recorded. The proportional chance criterion (PCC statistic was used to estimate agreement on multiple diagnostic possibilities because it accounts for the prevalence of individual categories in the sample. The kappa statistic was used to estimate agreement on six pathoanatomic diagnoses. Results In a sample of chronic LBP patients (n = 216 with high levels of disability and distress, 67% received a patho-anatomic diagnosis based on available reference standards, and 10% had more than one tissue origin of pain identified. For 27 diagnostic categories and combinations, chance clinical agreement

  19. SITE SPECIFIC REFERENCE PERSON PARAMETERS AND DERIVED CONCENTRATION STANDARDS FOR THE SAVANNAH RIVER SITE

    Energy Technology Data Exchange (ETDEWEB)

    Jannik, T.

    2013-03-14

    The purpose of this report is twofold. The first is to develop a set of behavioral parameters for a reference person specific for the Savannah River Site (SRS) such that the parameters can be used to determine dose to members of the public in compliance with Department of Energy (DOE) Order 458.1 “Radiation Protection of the Public and the Environment.” A reference person is a hypothetical, gender and age aggregation of human physical and physiological characteristics arrived at by international consensus for the purpose of standardizing radiation dose calculations. DOE O 458.1 states that compliance with the annual dose limit of 100 mrem (1 mSv) to a member of the public may be demonstrated by calculating the dose to the maximally exposed individual (MEI) or to a representative person. Historically, for dose compliance, SRS has used the MEI concept, which uses adult dose coefficients and adult male usage parameters. Beginning with the 2012 annual site environmental report, SRS will be using the representative person concept for dose compliance. The dose to a representative person will be based on 1) the SRS-specific reference person usage parameters at the 95th percentile of appropriate national or regional data, which are documented in this report, 2) the reference person (gender and age averaged) ingestion and inhalation dose coefficients provided in DOE Derived Concentration Technical Standard (DOE-STD-1196-2011), and 3) the external dose coefficients provided in the DC_PAK3 toolbox. The second purpose of this report is to develop SRS-specific derived concentration standards (DCSs) for all applicable food ingestion pathways, ground shine, and water submersion. The DCS is the concentration of a particular radionuclide in water, in air, or on the ground that results in a member of the public receiving 100 mrem (1 mSv) effective dose following continuous exposure for one year. In DOE-STD-1196-2011, DCSs were developed for the ingestion of water, inhalation of

  20. IAEA nuclear data for applications: Cross section standards and the reference input parameter library (RIPL)

    International Nuclear Information System (INIS)

    Capote Noy, Roberto; Nichols, Alan L.; Pronyaev, Vladimir G.

    2003-01-01

    An integral part of the activities of the IAEA Nuclear Data Section involves the development of nuclear data for a wide range of user applications. When considering low-energy nuclear reactions induced by neutrons, photons and charged particles, a detailed knowledge is required of the production cross sections over a wide energy range, spectra of emitted particles and their angular distributions. Two highly relevant IAEA data development projects are considered in this paper. Neutron reaction cross-section standards represent the basic quantities needed in nuclear reaction cross-section measurements and evaluations. These standards and the covariance matrices of their uncertainties were previously evaluated and released in 1987. However, the derived uncertainties were subsequently considered to be unrealistic low due to the effect of the low uncertainties obtained in fitting the light element standards to the R-matrix model; as a result, evaluators were forced to scale up the uncertainties to 'expected values'. An IAEA Coordinated Research Project (CRP) entitled 'Improvement of the Standard Cross Sections for Light Elements' was initiated in 2002 to improve the evaluation methodology for the covariance matrix of uncertainty in the R-matrix model fits, and to produce R-matrix evaluations of the important light element standards. The scope of this CRP has been substantially extended to include the preparation of a full set of evaluated standard reactions and covariance matrices of their uncertainties. While almost all requests for nuclear data were originally addressed through measurement programmes, our theoretical understanding of nuclear phenomena has reached a reasonable degree of reliability and nuclear modeling has become standard practice in nuclear data evaluations (with measurements remaining crucial for data testing and benchmarking). Since nuclear model codes require a considerable amount of numerical input, the IAEA has instigated extensive efforts to

  1. 78 FR 21850 - Federal Motor Vehicle Safety Standards; Matters Incorporated by Reference

    Science.gov (United States)

    2013-04-12

    ... to the 1985 Annual Book of ASTM Standards, Vol. 05.04, ``Test Methods for Rating Motor, Diesel... for Rating Motor, Diesel, Aviation Fuels, A2. Reference Materials and Blending Accessories, (``ASTM... [Docket No. NHTSA-2011-0185] RIN 2127-AL25 Federal Motor Vehicle Safety Standards; Matters Incorporated by...

  2. Referring to IAEA system to improve Chinese standards system on nuclear and radiation safety

    International Nuclear Information System (INIS)

    Shang Zhaorong; Wang Wenhai

    2010-01-01

    Referring to the standards system of IAEA, to build and improve the Chinese standards system of nuclear and radiation safety is a long term infrastructure work and an assurance to keep sustainable development of nuclear industry and nuclear technology application in China. The paper analyses the current main problem, and gives some suggestions on developing and improving the system. (authors)

  3. Compilation of elemental concentration data for NBS Biological and Environmental Standard Reference Materials

    International Nuclear Information System (INIS)

    Gladney, E.S.

    1980-07-01

    Concentration data on up to 76 elementals in 19 NBS Standard Reference Materials have been collected from 325 journal articles and technical reports. These data are summarized into mean +- one standard deviation values and compared with available data from NBS and other review articles. Data are presented on the analytical procedures employed and all raw data are presented in appendixes

  4. Standardization of reference radiation field of beta for 85Kr using extrapolation chamber

    International Nuclear Information System (INIS)

    Nazaroh; Fendinugroho

    2013-01-01

    Standardization of reference radiation field of beta for 85 Kr in PTKMR-BATAN Laboratory has been performed at the SDD's 30 cm by using extrapolation chamber detector, coupled with Uni dose electrometer. The result was : (8.98±3 %) mGy/h, at 95 % confidence level. The aim of standardization of reference radiation field is to support radiation protection and safety program, provided by the International Atomic Energy Agency to its Member States, included BATAN-Indonesia, especially, PTKMR. The aim of radiation protection program and safety program is to promote an internationally harmonized approach for radiation measurement in protection level, besides for calibration of radiation measuring instrument, which users spread across Indonesia, with the number of about 795 firms in the year of 2012. These benefits can be felt by workers, communities and the environment, because by calibration, measurement survey meter, pocket dosimeter and TLD to be more accurate so that the radiation dose received by radiation workers is accurate and can be ascertained in a specified period, not to exceed a predetermined NBD by BAPETEN. The aim of this calibration is appropriate with the primary objective of calibration on IAEA/TRS16:2000. (author)

  5. Characterization of reference standards for dirt by Laser Ablation Induced Photoacoustics (LAIP)

    International Nuclear Information System (INIS)

    Orzi, D J O; Bilmes, G M; Morel, E N; Torga, J R; Roviglione, A N

    2010-01-01

    Measurements of surface cleanliness and dirt characterization are important problems in a wide range of processes in industry and production. Standard methods are in most cases cumbersome laboratory procedures that must be performed out of the production lines. Instruments and methods for cleanliness determination and dirt characterization require reference standards for calibration. For that purpose we built a possible dirt reference standard (DRS) made by films of graphite grease subjected to heat treatment for mechanical stabilization. The DRS characterization was performed by Laser Ablation Induced Photoacoustics (LAIP). The measurement of the thickness of the films was made by low-coherence interferometry.

  6. Re-evaluation and extension of the scope of elements in US Geological Survey Standard Reference Water Samples

    Science.gov (United States)

    Peart, D.B.; Antweiler, Ronald C.; Taylor, Howard E.; Roth, D.A.; Brinton, T.I.

    1998-01-01

    More than 100 US Geological Survey (USGS) Standard Reference Water Samples (SRWSs) were analyzed for numerous trace constituents, including Al, As, B, Ba, Be, Bi, Br, Cd, Cr, Co, Cu, I, Fe, Pb, Li, Mn, Mo, Ni, Rb, Sb, Se, Sr, Te, Tl, U, V, Zn and major elements (Ca, Mg, Na, SiO2, SO4, Cl) by inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry. In addition, 15 USGS SRWSs and National Institute of Standards and Technology (NIST) standard reference material (SRM) 1641b were analyzed for mercury using cold vapor atomic fluorescence spectrometry. Also USGS SRWS Hg-7 was analyzed using isotope dilution-inductively coupled plasma mass spectrometry. The results were compared with the reported certified values of the following standard reference materials: NIST SRM 1643a, 1643b, 1643c and 1643d and National Research Council of Canada Riverine Water Reference Materials for Trace Metals SLRS-1, SLRS-2 and SLRS-3. New concentration values for trace and major elements in the SRWSs, traceable to the certified standards, are reported. Additional concentration values are reported for elements that were neither previously published for the SRWSs nor traceable to the certified reference materials. Robust statistical procedures were used that were insensitive to outliers. These data can be used for quality assurance/quality control purposes in analytical laboratories.

  7. Determination of polychlorinated dibenzo-p-dioxin and dibenzofuran congeners in air particulate and marine sediment standard reference materials (SRMs).

    Science.gov (United States)

    Chiu, C H; Turle, R; Poole, G; Thibert, B; Brubaker, W W; Schantz, M M; Wise, S A

    2001-02-01

    Due to the limited number of environmental matrix certified reference materials (CRMs) with assigned values for natural levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), an interlaboratory study was undertaken by the National Institute of Standards and Technology (NIST) and Environment Canada to establish reference concentration values for selected PCDD/Fs in two well-characterized NIST Standard Reference Materials (SRMs): SRM 1649a (Urban Dust) and SRM 1944 (New York/New Jersey Waterway Sediment). Results from 14 laboratories were used to provide reference values for the seventeen 2, 3, 7, 8-substituted PCDD/F congeners, the totals for individual tetra- through hepta-substituted PCDD/F homologues, and the total amount of tetra- through hepta-substituted PCDD/Fs. The mass fractions for the individual 2, 3, 7, 8-substituted congeners range from approximately 0.01 microg/kg to 7 microg/kg dry mass.

  8. Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point

    Directory of Open Access Journals (Sweden)

    Azmil Haizam Ahmad Tarmizi

    2008-01-01

    Full Text Available This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 °C in palm oil, 22.7 ± 0.4 °C in palm olein and 53.4 ± 0.2 °C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of –20 °C, 0 °C, 6 °C and 24 °C upon storage for one year.

  9. Results of the PEP`93 intercomparison of reference cell calibrations and newer technology performance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Osterwald, C.R.; Emery, K. [National Renewable Energy Lab., Golden, CO (United States); Anevsky, S. [All-Union Research Inst. for Optophysical Measurements, Moscow (Russian Federation)] [and others

    1996-05-01

    This paper presents the results of an international intercomparison of photovoltaic (PV) performance measurements and calibrations. The intercomparison, which was organized and operated by a group of experts representing national laboratories from across the globe (i.e., the authors of this paper), was accomplished by circulating two sample sets. One set consisted of twenty silicon reference cells that would, hopefully, form the basis of an international PV reference scale. A qualification procedure applied to the calibration results gave average calibration numbers with an overall standard deviation of less than 2% for the entire set. The second set was assembled from a wide range of newer technologies that present unique problems for PV measurements. As might be expected, these results showed much larger differences among laboratories. Methods were then identified that should be used to measure such devices, along with problems to avoid.

  10. Measurement of susceptibility artifacts with histogram-based reference value on magnetic resonance images according to standard ASTM F2119.

    Science.gov (United States)

    Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V

    2015-12-01

    The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.

  11. Measurement of the depth of narrow slotted sections in eddy current reference standards

    Science.gov (United States)

    Kim, Young-Joo; Kim, Young-gil; Ahn, Bongyoung; Yoon, Dong-Jin

    2007-02-01

    The dimensions of the slots in eddy current (EC) reference standards are too narrow to be measured by general depth measurement methods such as the optical (laser) or stylus methods. However, measurement of the dimensions of the machined slots is a prerequisite to using the blocks as references. The present paper suggests a measurement method for the slotted section using an ultrasonic test. The width and depth of the slots measured in our study are roughly 0.1 mm and 0.5 mm, respectively. The time of flight (TOF) of the ultrasonic wave was measured precisely. The ultrasonic velocity in the material of the EC reference standard was calculated with the measured values of the TOF and its thickness. Reflected waves from the tip of the slot and the bottom surface of the EC standard were successfully classified. Using this method we have successfully determined the depth of the slotted section.

  12. Standard digital reference images for investment steel castings for aerospace applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 The digital reference images provided in the adjunct to this standard illustrate various types and degrees of discontinuities occurring in thin-wall steel investment castings. Use of this standard for the specification or grading of castings requires procurement of the adjunct digital reference images which illustrate the discontinuity types and severity levels. They are intended to provide the following: 1.1.1 A guide enabling recognition of thin-wall steel casting discontinuities and their differentiation both as to type and degree through digital radiographic examination. 1.1.2 Example digital radiographic illustrations of discontinuities and a nomenclature for reference in acceptance standards, specifications and drawings. 1.2 Two illustration categories are covered as follows: 1.2.1 Graded—Six common discontinuity types each illustrated in eight degrees of progressively increasing severity. 1.2.2 Ungraded—Twelve single illustrations of additional discontinuity types and of patterns and imper...

  13. The use of high accuracy NAA for the certification of NIST Standard Reference Materials

    International Nuclear Information System (INIS)

    Becker, D.A.; Greenberg, R.R.; Stone, S.

    1991-01-01

    Neutron activation analysis (NAA) is only one of many analytical techniques used at the National Institute of Standards and Technology (NIST) for the certification of NIST Standard Reference Materials (SRMs). We compete daily against all of the other available analytical techniques in terms of accuracy, precision, and the cost required to obtain that requisite accuracy and precision. Over the years, the authors have found that NAA can and does compete favorably with these other techniques because of its' unique capabilities for redundancy and quality assurance. Good examples are the two new NIST leaf SRMs, Apple Leaves (SRM 1515) and Peach Leaves (SRM 1547). INAA was used to measure the homogeneity of 12 elements in 15 samples of each material at the 100 mg sample size. In addition, instrumental and radiochemical NAA combined for 27 elemental determinations, out of a total of 54 elemental determinations made on each material with all NIST techniques combined. This paper describes the NIST NAA procedures used in these analyses, the quality assurance techniques employed, and the analytical results for the 24 elements determined by NAA in these new botanical SRMs. The NAA results are also compared to the final certified values for these SRMs

  14. Establishing the traceability of a uranyl nitrate solution to a standard reference material

    International Nuclear Information System (INIS)

    Jackson, C.H.; Clark, J.P.

    1978-01-01

    A uranyl nitrate solution for use as a Working Calibration and Test Material (WCTM) was characterized, using a statistically designed procedure to document traceability to National Bureau of Standards Reference Material (SPM-960). A Reference Calibration and Test Material (PCTM) was prepared from SRM-960 uranium metal to approximate the acid and uranium concentration of the WCTM. This solution was used in the characterization procedure. Details of preparing, handling, and packaging these solutions are covered. Two outside laboratories, each having measurement expertise using a different analytical method, were selected to measure both solutions according to the procedure for characterizing the WCTM. Two different methods were also used for the in-house characterization work. All analytical results were tested for statistical agreement before the WCTM concentration and limit of error values were calculated. A concentration value was determined with a relative limit of error (RLE) of approximately 0.03% which was better than the target RLE of 0.08%. The use of this working material eliminates the expense of using SRMs to fulfill traceability requirements for uranium measurements on this type material. Several years' supply of uranyl nitrate solution with NBS traceability was produced. The cost of this material was less than 10% of an equal quantity of SRM-960 uranium metal

  15. 34 CFR 73.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct standards... of Education STANDARDS OF CONDUCT § 73.1 Cross-reference to employee ethical conduct standards and... branch-wide Standards of Ethical Conduct at 5 CFR part 2635 and to the Department of Education regulation...

  16. Interpreting Results from the Standardized UXO Test Sites

    National Research Council Canada - National Science Library

    May, Michael; Tuley, Michael

    2007-01-01

    ...) and the Environmental Security Technology Certification Program (ESCTP) to complete a detailed analysis of the results of testing carried out at the Standardized Unexploded Ordnance (UXO) Test Sites...

  17. Comparison of US Birth Weight References and the International Fetal and Newborn Growth Consortium for the 21st Century Standard

    DEFF Research Database (Denmark)

    Kozuki, Naoko; Katz, Joanne; Christian, Parul

    2015-01-01

    ) status. OBJECTIVES: To compare the birth weight distributions of the INTERGROWTH-21st international standard to commonly used US references and examine the differences in the prevalence and neonatal mortality risk of SGA status (below the 10th percentile of a population reference). DESIGN, SETTING...... variance. MAIN OUTCOMES AND MEASURES: We examine neonatal mortality (death within the first 28 days after birth) as the main outcome measure. RESULTS: The pooled SGA prevalence was 23.7% (95% CI, 16.5%-31.0%) using the INTERGROWTH-21st standard compared with 36.0% (95% CI, 27.0%-45.0%) with the US 2000...... and no significant change in the associated neonatal mortality risk, resulting in a decrease in the percentage of neonatal death attributable to SGA. Our study sheds light on how previously published studies on SGA status may be reinterpreted with the introduction of this new birth weight standard....

  18. Standard reference data for the air-liquid and vapor-liquid surface tension of benzene

    Czech Academy of Sciences Publication Activity Database

    Součková, Monika; Klomfar, Jaroslav; Pátek, Jaroslav

    2013-01-01

    Roč. 356, October (2013), s. 329-337 ISSN 0378-3812 R&D Projects: GA ČR GA101/09/0010 Institutional support: RVO:61388998 Keywords : benzene * surface tension * experimental data * standard reference data Subject RIV: BJ - Thermodynamics Impact factor: 2.241, year: 2013 http://www.sciencedirect.com/science/article/pii/S0378381213004196

  19. Body Parameters of Czech Breastfed Children Compared to the Czech References and WHO Growth Standards

    Czech Academy of Sciences Publication Activity Database

    Riedlová, J.; Vignerová, J.; Paulová, M.; Musil, V.; Brabec, Marek; Schneidrová, D.

    2017-01-01

    Roč. 44, č. 7 (2017), s. 593-599 ISSN 0301-4460 Grant - others:GA MZd(CZ) NS9974 Institutional support: RVO:67985807 Keywords : breastfed children * Czech reference * Growth charts * WHO growth standards Subject RIV: BB - Applied Statistics, Operational Research OBOR OECD: Statistics and probability Impact factor: 1.240, year: 2016

  20. 78 FR 57293 - Distribution of Reference Biological Standards and Biological Preparations

    Science.gov (United States)

    2013-09-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES 42 CFR Part 7 [Docket No. CDC-2013-0013] RIN 0920-AA52 Distribution of Reference Biological Standards and Biological Preparations AGENCY: Centers for Disease Control and Prevention (HHS/CDC), Department of Health and Human Services (HHS). ACTION: Confirmation of...

  1. 78 FR 47319 - Fee Schedule for Reference Biological Standards and Biological Preparations

    Science.gov (United States)

    2013-08-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Fee Schedule for Reference Biological Standards and Biological Preparations AGENCY: Centers for Disease Control and... for Disease Control and Prevention (CDC), located within the Department of Health and Human Services...

  2. Determination of 25 elements in biological standard reference materials by neutron activation analysis

    International Nuclear Information System (INIS)

    Guzzi, G.; Pietra, R.; Sabbioni, E.

    1974-12-01

    Standard and Certified Reference Materials programme of the JRC includes the determination of trace elements in complex biological samples delivered by the U.S. National Bureau of Standards: Bovine liver (NBS SRM 1577), Orchard Leaves (NBS SRM 1571) and Tomato Leaves. The study has been performed by the use of neutron activation analysis. Due to the very low concentration of some elements, radiochemical groups or elemental separation procedures were necessary. The paper describes the techniques used to analyse 25 elements. Computer assisted instrumental neutron activation analysis with high resolution Ge(Li) spectrometry was considerably advantageous in the determination of Na, K, Cl, Mn, Fe, Rb and Co and in some cases of Ca, Zn, Cs, Sc, and Cr. For low contents of Ca, Mg, Ni and Si special chemical separation schemes, followed by Cerenkov counting have been developped. Two other separation procedures allowing the determination of As, Cd, Ga, Hg, Mo, Cu, Sr Se, Ba and P have been set up. The first, the simplified one involves the use of high resolution Ge(Li) detectors, the second, the more complete one involves a larger number of shorter measurements performed by simpler and more sensitive techniques, such as NaI(Tl) scintillation spectrometry and Cerenkov counting. The results obtained are presented and discussed

  3. Design and evaluation of a 10-mA DC current reference standard

    CERN Document Server

    Fernqvist, G; Pickering, J; Power, F

    2003-01-01

    A new DC current reference standard has been developed for high- current power converter calibration in the large hadron collider (LHC) project at the European Organization for Nuclear Research (CERN). This standard provides a near ideal 10-mA DC current with long-term drift of one part in 10/sup 6/ per year. The paper describes the requirements and the detailed design and evaluation of the unit. Since similar 10-V standards are commercially available, the paper concentrates on the unique current output capability of this device. (4 refs).

  4. Implementation of a reference standard and proficiency testing programme by the World Wide Antimalarial Resistance Network (WWARN

    Directory of Open Access Journals (Sweden)

    Barnes Karen I

    2010-12-01

    Full Text Available Abstract Background The Worldwide Antimalarial Resistance Network (WWARN is a global collaboration to support the objective that anyone affected by malaria receives effective and safe drug treatment. The Pharmacology module aims to inform optimal anti-malarial drug selection. There is an urgent need to define the drug exposure - effect relationship for most anti-malarial drugs. Few anti-malarials have had their therapeutic blood concentration levels defined. One of the main challenges in assessing safety and efficacy data in relation to drug concentrations is the comparability of data generated from different laboratories. To explain differences in anti-malarial pharmacokinetics in studies with different measurement laboratories it is necessary to confirm the accuracy of the assay methods. This requires the establishment of an external quality assurance process to assure results that can be compared. This paper describes this process. Methods The pharmacology module of WWARN has established a quality assurance/quality control (QA/QC programme consisting of two separate components: 1. A proficiency testing programme where blank human plasma spiked with certified reference material (CRM in different concentrations is sent out to participating bioanalytical laboratories. 2. A certified reference standard programme where accurately weighed amounts of certified anti-malarial reference standards, metabolites, and internal standards are sent to participating bioanalytical and in vitro laboratories. Conclusion The proficiency testing programme is designed as a cooperative effort to help participating laboratories assess their ability to carry out drug analysis, resolve any potential problem areas and to improve their results - and, in so doing, to improve the quality of anti-malarial pharmacokinetic data published and shared with WWARN. By utilizing the same source of standards for all laboratories, it is possible to minimize bias arising from poor

  5. The NIST natural-matrix radionuclide standard reference material program for ocean studies

    International Nuclear Information System (INIS)

    Inn, K.G.W.; Zhichao Lin; Zhongyu Wu; MacMahon, C.; Filliben, J.J.; Krey, P.; Feiner, M.; Harvey, J.

    2001-01-01

    In 1997, the Low-level Working Group of the International Committee on Radionuclide Metrology met in Boston, MA (USA) to define the characteristics of a new set of environmental radioactivity reference materials. These reference materials were to provide the radiochemist with the same analytical challenges faced when assaying environmental samples. It was decided that radionuclide bearing natural materials should be collected from sites where there had been sufficient time for natural processes to redistribute the various chemically different species of the radionuclides. Over the succeeding years, the National Institute of Standards and Technology (NIST), in cooperation with other highly experienced laboratories, certified and issued a number of these as low-level radioactivity Standard Reference Materials (SRMs) for fission and activation product and actinide concentrations. The experience of certifying these SRMs has given NIST the opportunity to compare radioanalytical methods and learn of their limitations. NIST convened an international workshop in 1994 to define the natural-matrix radionuclide SRM needs for ocean studies. The highest priorities proposed at the workshop were for sediment, shellfish, seaweed, fish flesh and water matrix SRMs certified for mBq per sample concentrations of 90 Sr, 137 Cs and 239 Pu + 240 Pu. The most recent low-level environmental radionuclide SRM issued by NIST, Ocean Sediment (SRM 4357) has certified and uncertified values for the following 22 radionuclides: 40 K, 90 Sr, 129 I, 137 Cs, 155 Eu, 210 Pb, 210 Po, 212 Pb, 214 Bi, 226 Ra, 228 Ra, 228 Th, 230 Th, 232 Th, 234 U, 235 U, 237 Np, 238 U, 238 Pu, 239 Pu + 240 Pu, and 241 Am. The uncertainties for a number of the certified radionuclides are non-symmetrical and relatively large because of the non-normal distribution of reported values. NIST is continuing its efforts to provide the ocean studies community with additional natural matrix radionuclide SRMs. The freeze

  6. Fathead minnows (Pimephales promelas) and goldfish (Carassius auratus) as standard fish in bioassays and their reaction to potential reference toxicants

    Energy Technology Data Exchange (ETDEWEB)

    Adelman, I.R.; Smith, L.L. Jr.

    1976-02-01

    Fathead minnows (Pimephales promelas) and goldfish (Carassius auratus) were compared for their suitability as standard bioassay fish. Both species showed the same variability of bioassay results when tested with four toxicants. Fathead minnows are recommended on the basis of their small size and on their capability for use in complete life cycle tests. On the basis of minimum variability of bioassay results, sodium chloride was superior for use as a reference toxicant. Both sodium chloride and pentachlorophenol seemed capable of detecting abnormal fish. On the basis of seven listed criteria either sodium chloride or pentachlorophenol would be acceptable as a reference toxicant.

  7. ANSI/ASHRAE/IES Standard 90.1-2016 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eley, Charles [Eley and Associates, Hobe Sound, FL (United States)

    2017-09-29

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1-2016 (Standard 90.1-2016). The PRM can be used to demonstrate compliance with the standard and to rate the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. Use of the PRM for demonstrating compliance with Standard 90.1 is a new feature of the 2016 edition. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM.

  8. 42 CFR 493.1281 - Standard: Comparison of test results.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Comparison of test results. 493.1281 Section 493.1281 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the...

  9. New birth weight reference standards customised to birth order and sex of babies from South India

    Directory of Open Access Journals (Sweden)

    Kumar Velusamy Saravana

    2013-02-01

    Full Text Available Abstract Background The foetal growth standards for Indian children which are available today suffer due to methodological problems. These are, for example, not adhering to the WHO recommendation to base gestational age on the number of completed weeks and secondly, not excluding mothers with risk factors. This study has addressed both the above issues and in addition provides birthweight reference ranges with regard to sex of the baby and maternal parity. Methods Data from the labour room register from 1996 to 2010 was obtained. A rotational sampling scheme was used i.e. the 12 months of the year were divided into 4 quadrants. All deliveries in January were considered to represent the first quadrant. Similarly all deliveries in April, July and October were considered to represent 2nd, 3rd and 4th quadrants. In each successive year different months were included in each quadrant. Only those mothers aged 20–39 years and delivered between 24 to 42 weeks gestational age were considered. Those mothers with obstetric risk factors were excluded. The reference standards were fitted using the Generalized Additive Models for Location Scale and Shape (GAMLSS method for Box – Cox t distribution with cubic spline smoothing. Results There were 41,055 deliveries considered. When women with risk factors were excluded 19,501 deliveries could be included in the final analysis. The male babies of term firstborn were found to be 45 g heavier than female babies. The mean birthweights were 2934 g and 2889.5 g respectively. Similarly, among the preterm babies, the first born male babies weighed 152 g more than the female babies. The mean birthweights were 1996 g and 1844 g respectively. In the case of later born babies, the term male babies weighed 116grams more than the females. The mean birth weights were 3085 grams and 2969 grams respectively. When considering later born preterm babies, the males outweighed the female babies by 111 grams. The

  10. 45 CFR 680.10 - Definitions; cross-references to employee ethical conduct standards and financial disclosure...

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Definitions; cross-references to employee ethical... Foundation § 680.10 Definitions; cross-references to employee ethical conduct standards and financial...-references to employee ethical conduct standards and financial disclosure regulations. Members of the...

  11. 49 CFR 1019.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Cross-reference to employee ethical conduct... Cross-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees of the Surface Transportation Board also should refer to the executive branch Standards of Ethical...

  12. 230Th-234U Model-Ages of Some Uranium Standard Reference Materials

    International Nuclear Information System (INIS)

    Williams, R.W.; Gaffney, A.M.; Kristo, M.J.; Hutcheon, I.D.

    2009-01-01

    The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the 230 Th- 234 U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumption of the initial 230 Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U 3 O 8 ) may be assumed with confidence. We present here 230 Th- 234 U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history

  13. 230Th-234U Model-Ages of Some Uranium Standard Reference Materials

    Energy Technology Data Exchange (ETDEWEB)

    Williams, R W; Gaffney, A M; Kristo, M J; Hutcheon, I D

    2009-05-28

    The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the {sup 230}Th-{sup 234}U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumption of the initial {sup 230}Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U{sub 3}O{sub 8}) may be assumed with confidence. We present here {sup 230}Th-{sup 234}U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history.

  14. Construction of a new growth references for China based on urban Chinese children: comparison with the WHO growth standards.

    Science.gov (United States)

    Zong, Xin-Nan; Li, Hui

    2013-01-01

    Growth references for Chinese children should be updated due to the positive secular growth trends and the progress of the smoothing techniques. Human growth differs among the various ethnic groups, so comparison of the China references with the WHO standards helps to understand such differences. The China references, including weight, length/height, head circumference, weight-for-length/height and body mass index (BMI) aged 0-18 years, were constructed based on 69,760 urban infants and preschool children under 7 years and 24,542 urban school children aged 6-20 years derived from two cross-sectional national surveys. The Cole's LMS method is employed for smoothing the growth curves. The merged data sets resulted in a smooth transition at age 6-7 years and continuity of curves from 0 to 18 years. Varying differences were found on the empirical standard deviation (SD) curves in each indicator at nearly all ages between China and WHO. The most noticeable differences occurred in genders, final height and boundary centiles curves. Chinese boys' weight is strikingly heavier than that of the WHO at age 6-10 years. The height is taller than that of the WHO for boys below 15 years and for girls below 13, but is significantly lower when boys over 15 years and girls over 13. BMI is generally higher than that of the WHO for boys at age 6-16 years but appreciably lower for girls at 3-18 years. The differences between China and WHO are mainly caused by the reference populations of different ethnic backgrounds. For practitioners, the choices of the standards/references depend on the population to be assessed and the purpose of the study. The new China references could be applied to facilitate the standardization assessment of growth and nutrition for Chinese children and adolescents in clinical pediatric and public health.

  15. ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-05-01

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either of those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.

  16. 18 CFR 38.2 - Incorporation by reference of North American Energy Standards Board Wholesale Electric Quadrant...

    Science.gov (United States)

    2010-04-01

    ... reference of North American Energy Standards Board Wholesale Electric Quadrant standards. 38.2 Section 38.2 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY... UTILITIES § 38.2 Incorporation by reference of North American Energy Standards Board Wholesale Electric...

  17. Stability of Working Reference Standards for Hybrid K-Edge Densitometer Quality Assurance

    International Nuclear Information System (INIS)

    Guzzardo, T.; Pickett, C.A.; McElroy, R.; Croft, S.; Garrison, J.; Venkataraman, R.

    2015-01-01

    The relatively short working life of aqueous solution standards of actinides for the calibration and quality control of Hybrid K-Edge Densitometer (HKED) measurements necessitates the development of a stable matrix material less susceptible to degradation. Degradation in the form of evaporation, radiolysis, settling, sloshing, and sediment formation can all reduce the reliability and working life of an aqueous standard. These factors make aqueous solutions inadequate for long-term quality assurance measurements designed to detect weak or subtle trends in system performance. Epoxy, studied here, is an alternative matrix material that may be less vulnerable to degradation. An additional benefit of epoxy is that standards can easily be characterized as sealed sources which allows for simplified administrative controls during shipping and storage. The stability of working reference standards consisting of U 3 O 8 in an epoxy matrix for use in the HKED has been tracked for over three years through repeated X-ray Fluorescence (XRF) and K-Edge (KED) measurements. A set of six epoxy standards ranging in concentration from 1 g/l to 76 g/l uranium were determined to be stable, within the expected accuracy of the system, over the period of analysis. During this time, no effort was made to enhance the stability of the epoxy standards; the radial measurement position was not controlled and in the middle of the analysis period the HKED system and standards were shipped from the vendor's factory to the customer. Epoxy standards afford numerous benefits over those created from aqueous solutions and should be considered when developing HKED standards for quality assurance measurements. The stability of the epoxy allows the development of working standards of a stability and robustness sufficient for use in a proposed international round-robin exercise based on the exchange of such standards. (author)

  18. Anthropometry as a tool for measuring malnutrition: impact of the new WHO growth standards and reference.

    Science.gov (United States)

    Duggan, M B

    2010-01-01

    Anthropometry is a useful tool, both for monitoring growth and for nutritional assessment. The publication by WHO of internationally agreed growth standards in 1983 facilitated comparative nutritional assessment and the grading of childhood malnutrition. New growth standards for children under 5 years and growth reference for children aged 5-19 years have recently (2006 and 2007) been published by WHO. Growth of children growth reference study involving children from six countries, selected for optimal child-rearing practices (breastfeeding, non-smoking mothers). They therefore constitute a growth standard. Growth data for older children were drawn from existing US studies, and upward skewing was avoided by excluding overweight subjects. These constitute a reference. More indicators are now included to describe optimal early childhood growth and development, e.g. BMI for age and MUAC for age. The growth reference for older children (2007) focuses on linear growth and BMI; weight-for-age data are age-limited and weight-for-height is omitted. Differences in the 2006 growth pattern from the previous reference for children toddler. The spread of values for height and weight for height is narrower in the 2006 dataset, such that the lower limit of the normal range for both indices is set higher than in the previous dataset. This means that a child will be identified as moderately or severely underweight for height (severe acute malnutrition) at a greater weight for height than previously. The implications for services for malnourished children have been recognised and strategies devised. The emphasis on BMI-for-age as the indicator for thinness and obesity in older children is discussed. The complexity of calculations for health cadres without mathematical backgrounds or access to calculation software is also an issue. It is possible that the required charts and tables may not be accessible to those working in traditional health/nutrition services which are often poorly

  19. A new large-volume metal reference standard for radioactive waste management.

    Science.gov (United States)

    Tzika, F; Hult, M; Stroh, H; Marissens, G; Arnold, D; Burda, O; Kovář, P; Suran, J; Listkowska, A; Tyminski, Z

    2016-03-01

    A new large-volume metal reference standard has been developed. The intended use is for calibration of free-release radioactivity measurement systems and is made up of cast iron tubes placed inside a box of the size of a Euro-pallet (80 × 120 cm). The tubes contain certified activity concentrations of (60)Co (0.290 ± 0.006 Bq g(-1)) and (110m)Ag (3.05 ± 0.09 Bq g(-1)) (reference date: 30 September 2013). They were produced using centrifugal casting from a smelt into which (60)Co was first added and then one piece of neutron irradiated silver wire was progressively diluted. The iron castings were machined to the desirable dimensions. The final material consists of 12 iron tubes of 20 cm outer diameter, 17.6 cm inner diameter, 40 cm length/height and 245.9 kg total mass. This paper describes the reference standard and the process of determining the reference activity values. © The Author 2015. Published by Oxford University Press.

  20. Measurement of polybrominated diphenyl ethers in environmental matrix standard reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Stapleton, H.; Schantz, M.; Wise, S. (National Institute of Standards and Technology)

    2004-09-15

    Polybrominated diphenyl ethers (PBDEs) are a class of emerging contaminants of concern as many studies have now demonstrated that these compounds are bioaccumulative, persistent and increasing in concentration in the environment. PBDEs are being detected in almost every environmental sample examined, and they have even been measured in samples collected in the Arctic, further demonstrating their persistence and potential for long range transport. More and more studies are continuing to examine the fate and transport of these flame retardant compounds in environmental samples and as such, reference materials are needed to provide quality control on these measurements. The National Institute of Standards and Technology (NIST) supports a national Standard Reference Material (SRM) program for measurement of organic contaminants such as PCBs, PAHs and chlorinated pesticides in environmental matrices. This current study was undertaken to provide reference measurements for PBDEs in selected SRMs that are currently used by various laboratories throughout the United States. These SRMs include matrices such as marine mammal blubber, lake trout tissue, mussel tissue, sediment, house dust and human serum. We report here reference values for 22 PBDE congeners that have been quantified in these seven types of SRMs.

  1. Procedure and reference standard to determine the structural resolution in coordinate metrology

    Science.gov (United States)

    Illemann, Jens; Bartscher, Markus; Jusko, Otto; Härtig, Frank; Neuschaefer-Rube, Ulrich; Wendt, Klaus

    2014-06-01

    A new procedure and reference standards for specifying the structural resolution in coordinate metrology traceable to the SI unit the metre are proposed. With the definition of the structural resolution, a significant gap will be closed to complete ‘acceptance and verification tests’ of the coordinate measuring systems (CMSs) which are specified in the ISO 10360 series dealing with tactile sensors, optical sensors, and x-ray computed tomography measurement systems (CTs). The proposed new procedure uses reference standards with circular rounded edges. The idea is to measure the radius of curvature on a calibrated round edge structure. From the deviation between the measured and the calibrated radius, an analogue Gaussian broadening of the measurement system is determined. This value is a well-defined and easy-to-apply measure to define the structural resolution for dimensional measurements. It is applicable to CMSs which are based on different sensing principles, e.g. tactile, optical and CT systems. On the other hand, it has a physical meaning similar to the classical optical point-spread function. It makes it possible to predict which smallest details the CMS is capable of measuring reliably for an arbitrary object shape. The theoretical background of the new procedure is given, an appropriate reference standard is described and comparative, quantitative measurement data of CMSs featuring different sensors are shown.

  2. A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference.

    Directory of Open Access Journals (Sweden)

    Helen L Storey

    Full Text Available Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates.

  3. Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of the electrical performance of a photovoltaic cell under simulated sunlight by means of a calibrated reference cell procedure. 1.2 Electrical performance measurements are reported with respect to a select set of standard reporting conditions (SRC) (see Table 1) or to user-specified conditions. 1.2.1 The SRC or user-specified conditions include the cell temperature, the total irradiance, and the reference spectral irradiance distribution. 1.3 This test method is applicable only to photovoltaic cells with a linear response over the range of interest. 1.4 The cell parameters determined by this test method apply only at the time of test, and imply no past or future performance level. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this s...

  4. Standard Reference Test Method for Making Potentiostatic and Potentiodynamic Anodic Polarization Measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method covers an experimental procedure for checking experimental technique and instrumentation. If followed, this test method will provide repeatable potentiostatic and potentiodynamic anodic polarization measurements that will reproduce data determined by others at other times and in other laboratories provided all laboratories are testing reference samples from the same lot of Type 430 stainless steel. 1.2 Values stated in SI units are to be regarded as the standard. Inch-pound units given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Thermal Expansion and Density Data of UO2 and Simulated Fuel for Standard Reference

    International Nuclear Information System (INIS)

    Yang, Jae Hwan; Na, S. H.; Lee, J. W.; Kang, K. H.

    2010-01-01

    Standard Reference Data (SRD) is the scientific, technical data whose reliability and accuracy are evaluated by scientist group. Since SRD has a great impact on the improvement of national competitiveness by stirring up technological innovation in every sector of industries, many countries are making great efforts on establishing SRD in various areas. Data center for nuclear fuel material in Korea Atomic Energy Research Institute plays a role to providing property data of nuclear fuel material at high temperature, pressure, and radiation which are essential for the safety evaluation of nuclear power. In this study, standardization of data on thermal expansion and density of UO 2 were carried out in the temperature range from 300 K to 3100 K via uncertainty evaluation of indirectly produced data. Besides, standardization of data on thermal expansion and density of simulated fuel were also done in the temperature range from 350 K to 1750 K via uncertainty evaluation of directly produced data

  6. 13 CFR 105.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... ethical conduct standards and financial disclosure regulations. 105.101 Section 105.101 Business Credit... RESPONSIBILITIES Standards of Conduct § 105.101 Cross-reference to employee ethical conduct standards and financial... to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR part 2635 and the...

  7. 18 CFR 3c.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... employee ethical conduct standards and financial disclosure regulations. 3c.1 Section 3c.1 Conservation of... STANDARDS OF CONDUCT § 3c.1 Cross-reference to employee ethical conduct standards and financial disclosure... branch-wide financial disclosure regulations at 5 CFR part 2634, the Standards of Ethical Conduct for...

  8. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme.

    Science.gov (United States)

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro

    2016-11-01

    Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) -1.292 ( n = 495, R 2  = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was -0.71%, -0.42% and -0.13%, respectively. For the combined precision, the equation y (CV) = -0.398 × (triglycerides value) + 1.797 ( n = 495, R 2  = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time.

  9. Standard Specification for Physical Characteristics of Nonconcentrator Terrestrial Photovoltaic Reference Cells

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This specification describes the physical requirements for primary and secondary terrestrial nonconcentrator photovoltaic reference cells. A reference cell is defined as a device that meets the requirements of this specification and is calibrated in accordance with Test Method E1125 or Test Method E1362. 1.2 Reference cells are used in the determination of the electrical performance of photovoltaic devices, as stated in Test Methods E948 and E1036. 1.3 Two reference cell physical specifications are described: 1.3.1 Small-Cell Package Design—A small, durable package with a low thermal mass, wide optical field-of-view, and standardized dimensions intended for photovoltaic devices up to 20 by 20 mm, and 1.3.2 Module-Package Design—A package intended to simulate the optical and thermal properties of a photovoltaic module design, but electric connections are made to only one photovoltaic cell in order to eliminate problems with calibrating series and parallel connections of cells. Physical dimensions ...

  10. Austenitic chromium nickel steel as standard reference material in measurement of thermal and temperature conductivity

    International Nuclear Information System (INIS)

    Binkele, L.

    1990-01-01

    A niobium-stabilized CrNi steel with the NBS designation SRM 735 is introduced as WLF standard reference material in a report by Hust and Giarratano, for the temperature range 300-1200 K and for thermal conductivities around 20 W/mk. However, its specification does not show it to be a direct member of the DIN family of CrNi steels. This report should be regarded as a continuation and supplement to the above-mentioned efforts in America. On the one hand, a solution of a possibly too-narrow specification is aimed at for the reference material, where it is important how sensitive the thermal conductivity is to changes in the chemical composition and changes of the manufacturing parameters and what accuracy can be reached for the reference values with the best measurement techniques. On the other hand, the data base should be expanded and the accuracy of the reference curve should be improved if possible. (orig./MM) [de

  11. Bias in the absorption coefficient determination of a fluorescent dye, standard reference material 1932 fluorescein solution

    International Nuclear Information System (INIS)

    DeRose, Paul C.; Kramer, Gary W.

    2005-01-01

    The absorption coefficient of standard reference material[registered] (SRM[registered]) 1932, fluorescein in a borate buffer solution (pH=9.5) has been determined at λ=488.0, 490.0, 490.5 and 491.0 nm using the US national reference UV/visible spectrophotometer. The purity of the fluorescein was determined to be 97.6% as part of the certification of SRM 1932. The solution measured was prepared gravimetrically by diluting SRM 1932 with additional borate buffer. The value of the absorption coefficient was corrected for bias due to fluorescence that reaches the detector and for dye purity. Bias due to fluorescence was found to be on the order of -1% for both monochromatic and polychromatic (e.g., diode-array based) spectrophotometers

  12. Age and gender leucocytes variances and references values generated using the standardized ONE-Study protocol

    DEFF Research Database (Denmark)

    Kverneland, Anders H.; Streitz, Mathias; Geissler, Edward

    2016-01-01

    blood flow cytometry. The performance of our protocols was challenged here by profiling samples from healthy volunteers to reveal age- and gender-dependent differences and to establish a standardized reference cohort for use in clinical trials. Whole blood samples from two different cohorts were...... analyzed (first cohort: n = 52, second cohort: n = 46, both 20–84 years with equal gender distribution). The second cohort was run as a validation cohort by a different operator. The “ONE Study” panels were applied to analyze expression of >30 different surface markers to enumerate proportional...... cohort. Thus, we have proven the utility of our strategy and generated reproducible reference ranges accounting for age- and gender-dependent differences, which are crucial for a better patient monitoring and individualized therapy....

  13. Standard reference material certification: contribution of NAA with a TRIGA reactor

    International Nuclear Information System (INIS)

    Orvini, E.; Speziali, M.; Salvini, A.; Herborg, C.

    2002-01-01

    Pavia has cooperative links with the major international agencies devoted to the certification of SRMs or CRMs as the Bureau Communautaire de Reference (BCR), the European Institute for Reference Materials and Measurement (IRMM), the USA National Institute of Standards and Technology (NIST) and the International Atomic Energy Agency (IAEA). During these cooperative works, a large amount of analytical data obtained with NAA has been compared, and meaningful methodological information achieved with respect to accuracy and precision in the analysis of several elements at different concentrations in various matrices. Analytical data on As, Cd, Cr, Co, Cu, Cs, Fe, Zn, K, Sc, U, Th, Al, Sb, Mn, V, Hg, Sr, Rb, Se,Pt, all the Rare Earths and halogens Br, Cl, I, have been obtained and contributed for the final certification

  14. Characterization of standard reference material 2944, Bi-ion-doped glass, spectral correction standard for red fluorescence

    International Nuclear Information System (INIS)

    DeRose, Paul C.; Smith, Melody V.; Anderson, Jeffrey R.; Kramer, Gary W.

    2013-01-01

    Standard Reference Material (SRM) 2944 is a cuvette-shaped, Bi-ion-doped glass, recommended for optimal use for relative spectral correction of emission from 590 nm to 805 nm and day-to-day performance verification of steady-state fluorescence spectrometers. Properties of this standard that influence its effective use or contribute to the uncertainty in its certified emission spectrum were explored here. These properties include its photostability, absorbance, dissolution rate in water, anisotropy and temperature coefficient of fluorescence intensity. The expanded uncertainties (k=2) in the certified spectrum are about 4% around the nominal peak maximum at 704 nm and increase to about 6% at the wings, using an excitation wavelength of 515 nm. -- Highlights: ► The fluorescence emission spectrum of SRM 2944 was determined for spectral correction. ► This Bi-ion-doped glass has been certified in the fluorescence region from 530 nm to 830 nm. ► Fluorescence properties of the glass were determined, e.g., anisotropy, lifetime. ► SRM 2944 is photostable under common visible lamp excitation, when UV light is not present

  15. 29 CFR 2703.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct standards and...-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees... of Ethical Conduct at 5 CFR part 2635; the Commission's regulations at 5 CFR part 8401, which...

  16. 12 CFR 264.101 - Cross-reference to employees' ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Cross-reference to employees' ethical conduct... § 264.101 Cross-reference to employees' ethical conduct standards and financial disclosure regulations... branch-wide standards of ethical conduct at 5 CFR part 2635 and the Board's regulation at 5 CFR part 6801...

  17. 12 CFR 336.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Cross-reference to employee ethical conduct... and Conduct § 336.1 Cross-reference to employee ethical conduct standards and financial disclosure... Branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Corporation regulation at 5 CFR part...

  18. 45 CFR 1105.1 - Cross-reference to employee ethical conduct standards and financial disclosure and financial...

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Cross-reference to employee ethical conduct... STANDARDS OF CONDUCT FOR EMPLOYEES § 1105.1 Cross-reference to employee ethical conduct standards and... ethical conduct at 5 CFR part 2635; the executive branch employees responsibilities and conduct...

  19. 49 CFR 99.735-1 - Cross-reference to ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Cross-reference to ethical conduct standards and... Transportation EMPLOYEE RESPONSIBILITIES AND CONDUCT General § 99.735-1 Cross-reference to ethical conduct... the executive branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Department of...

  20. 10 CFR 1010.102 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Cross-references to employee ethical conduct standards... ENERGY (GENERAL PROVISIONS) CONDUCT OF EMPLOYEES § 1010.102 Cross-references to employee ethical conduct... Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR part 2635, the DOE regulation at...

  1. 22 CFR 705.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Cross-reference to employee ethical conduct... INVESTMENT CORPORATION ADMINISTRATIVE PROVISIONS EMPLOYEE ETHICAL CONDUCT STANDARDS AND FINANCIAL DISCLOSURE REGULATIONS § 705.101 Cross-reference to employee ethical conduct standards and financial disclosure...

  2. 39 CFR 3000.735-101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct... employee ethical conduct standards and financial disclosure regulations. Employees of the Postal Regulatory Commission (Commission) are subject and should refer to the executive branch-wide Standards of Ethical...

  3. 5 CFR 1300.1 - Cross-reference to employees ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Cross-reference to employees ethical conduct standards and financial disclosure regulations. 1300.1 Section 1300.1 Administrative Personnel OFFICE OF MANAGEMENT AND BUDGET ADMINISTRATIVE PROCEDURES STANDARDS OF CONDUCT § 1300.1 Cross-reference...

  4. 16 CFR 1030.101 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... PRODUCT SAFETY COMMISSION GENERAL EMPLOYEE STANDARDS OF CONDUCT General § 1030.101 Cross-references to employee ethical conduct standards and financial disclosure regulations. Employees of the Consumer Product... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Cross-references to employee ethical conduct...

  5. The stability of uranium microspheres for future application as reference standard in analytical measurements

    Energy Technology Data Exchange (ETDEWEB)

    Middendorp, R.; Duerr, M.; Bosbach, D. [Forschungszentrum Juelich GmbH, IEK-6, 52428 Juelich (Germany)

    2016-07-01

    The monitoring of fuel-cycle facilities provides a tool to confirm the compliant operation, for example with respect to emissions into the environment or to supervise non-proliferation commitments. Hereby, anomalous situations can be detected in a timely manner and responsive action can be initiated to prevent an escalation into an event of severe consequence to society. In order to verify non-nuclear weapon states' compliance with the non-proliferation treaty (NPT), international authorities such as the International Atomic Energy Agency (IAEA) conduct inspections at facilities dealing with fissile or fertile nuclear materials. One measure consists of collection of swipe samples through inspectors for later analysis of collected nuclear material traces in the laboratory. Highly sensitive mass spectrometric methods provide a means to detect traces from nuclear material handling activities that provide indication of undeclared use of the facility. There are, however, no relevant (certified) reference materials available that can be used as calibration or quality control standards. Therefore, an aerosol-generation based process was established at Forschungszentrum Juelich for the production of spherical, mono-disperse uranium oxide micro-particles with accurately characterized isotopic compositions and amounts of uranium in the pico-gram range. The synthesized particles are studied with respect to their suitability as (certified) reference material in ultra-trace analysis. Several options for preparation and stabilization of the particles are available, where preparation of particles in suspension offers the possibility to produces specific particle mixtures. In order to assess the stability of particles, dissolution behavior and isotope exchange effects of particles in liquid suspension is studied on the bulk of suspended particles and also via micro-analytical methods applied for single particle characterization. The insights gained within these studies will

  6. 22 CFR 1001.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Cross-references to employee ethical conduct... FOUNDATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1001.1 Cross-references to employee ethical conduct... Foundation should refer to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR...

  7. Comparison BIPM.RI(I)-K8 of high dose-rate Ir-192 brachytherapy standards for reference air kerma rate of the PTB and the BIPM

    International Nuclear Information System (INIS)

    Kessler, C.; Allisy-Roberts, P.J.; Selbach, H.J.

    2015-01-01

    An indirect comparison of the standards for reference air kerma rate (RAKR) for 192 Ir high dose rate (HDR) brachytherapy sources of the Physikalisch-Technische Bundesanstalt (PTB), Germany, and of the Bureau International des Poids et Mesures (BIPM) was carried out at the PTB in September 2011. The comparison result, based on the calibration coefficients for a transfer standard and expressed as a ratio of the PTB and the BIPM standards for reference air kerma rate, is 1.0003 with a combined standard uncertainty of 0.0099. (authors)

  8. Retrospective Analysis of NIST Standard Reference Material 1450, Fibrous Glass Board, for Thermal Insulation Measurements

    Science.gov (United States)

    Zarr, Robert R; Heckert, N Alan; Leigh, Stefan D

    2014-01-01

    Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis. The data cover 36 years of activity by the National Institute of Standards and Technology (NIST) in developing and providing thermal insulation SRMs, specifically high-density molded fibrous-glass board, to the public. Collectively, the data sets cover two nominal thicknesses of 13 mm and 25 mm, bulk densities from 60 kg·m−3 to 180 kg·m−3, and mean temperatures from 100 K to 340 K. The analysis repetitively fits six models to the individual data sets. The most general form of the nested set of multilinear models used is given in the following equation: λ(ρ,T)=a0+a1ρ+a2T+a3T3+a4e−(T−a5a6)2where λ(ρ,T) is the predicted thermal conductivity (W·m−1·K−1), ρ is the bulk density (kg·m−3), T is the mean temperature (K) and ai (for i = 1, 2, … 6) are the regression coefficients. The least squares fit results for each model across all data sets are analyzed using both graphical and analytic techniques. The prevailing generic model for the majority of data sets is the bilinear model in ρ and T. λ(ρ,T)=a0+a1ρ+a2T One data set supports the inclusion of a cubic temperature term and two data sets with low-temperature data support the inclusion of an exponential term in T to improve the model predictions. Physical interpretations of the model function terms are described. Recommendations for future renewals of SRM 1450 are provided. An Addendum provides historical background on the origin of this SRM and the influence of the SRM on external measurement programs. PMID:26601034

  9. The uncertainty of reference standards--a guide to understanding factors impacting uncertainty, uncertainty calculations, and vendor certifications.

    Science.gov (United States)

    Gates, Kevin; Chang, Ning; Dilek, Isil; Jian, Huahua; Pogue, Sherri; Sreenivasan, Uma

    2009-10-01

    Certified solution standards are widely used in forensic toxicological, clinical/diagnostic, and environmental testing. Typically, these standards are purchased as ampouled solutions with a certified concentration. Vendors present concentration and uncertainty differently on their Certificates of Analysis. Understanding the factors that impact uncertainty and which factors have been considered in the vendor's assignment of uncertainty are critical to understanding the accuracy of the standard and the impact on testing results. Understanding these variables is also important for laboratories seeking to comply with ISO/IEC 17025 requirements and for those preparing reference solutions from neat materials at the bench. The impact of uncertainty associated with the neat material purity (including residual water, residual solvent, and inorganic content), mass measurement (weighing techniques), and solvent addition (solution density) on the overall uncertainty of the certified concentration is described along with uncertainty calculations.

  10. Direct calibration of GC/MS systems using SRM (Standard Reference Material) gas cylinders. Project report, January 1984-August 1985

    International Nuclear Information System (INIS)

    Byrd, G.D.; Richie, K.L.; Sniegoski, L.T.; White, E.

    1985-10-01

    A cryogenic trapping system has been developed for use in calibrating GC/MS systems for the analysis of volatile organic compounds. This system provides for direct Standard Reference Material (SRM) traceability on data generated on gaseous samples. The cryogenic trap is a coil of stainless steel tubing immersed in a cryogen to trap and preconcentrate organic species present in a gaseous sample. The trap also contains a heated injection port for the addition of isotopically labeled compounds for use in isotope dilution measurements. The first part of this research is concerned with the development of IDMS as an independent method for the quantification of analytes in gaseous samples to be used as standards. Results are presented for the determination of bromobenzene in nitrogen at nominal concentrations of 1 and 25 ppb. In the second part of the research, a calibration curve method was developed for using these standards in auditing the performance of GC/MS systems

  11. Determinations of elements in pepperbush standard reference material by neutron activation and X-ray fluorescence analyses

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Okada, Takayuki; Tatsumi, Toshiya; Kusakabe, Toshio; Katsurayama, Kousuke; Iwata, Shiro.

    1988-01-01

    Elemental contents in Pepperbush standard reference material have been determined by neutron activation and X-ray fluorescence analyses. The standard samples of orchard leaves, tomato leaves, pine needles and Kale are used for the experiment. In the neutron activation analysis, gamma-ray spectra of nuclei produced by (n,γ) reaction on Pepperbush and standard samples are measured with Ge detectors. In the X-ray fluorescence analysis, the samples are excited with X-rays from X-ray tube with rhodium anode, and the characteristic X-rays from samples are measured with a proportional counter or NaI(Tl) detector. From the gamma- and X-ray intensities, the elemental contents in Pepperbush are determined. As a result, the contents of seventeen elements, such as sodium, calcium, iron, etc., in Pepperbush are determined. (author)

  12. Standard Test Methods for Electrical Performance of Nonconcentrator Terrestrial Photovoltaic Modules and Arrays Using Reference Cells

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the electrical performance of photovoltaic modules and arrays under natural or simulated sunlight using a calibrated reference cell. 1.1.1 These test methods allow a reference module to be used instead of a reference cell provided the reference module has been calibrated using these test methods against a calibrated reference cell. 1.2 Measurements under a variety of conditions are allowed; results are reported under a select set of reporting conditions (RC) to facilitate comparison of results. 1.3 These test methods apply only to nonconcentrator terrestrial modules and arrays. 1.4 The performance parameters determined by these test methods apply only at the time of the test, and imply no past or future performance level. 1.5 These test methods apply to photovoltaic modules and arrays that do not contain series-connected photovoltaic multijunction devices; such module and arrays should be tested according to Test Methods E 2236. 1.6 The values stated in SI units are to be re...

  13. Catalog of NBS standard reference materials, 1975--76 edition. Special pub

    International Nuclear Information System (INIS)

    Seward, R.W.

    1975-06-01

    This Catalog lists and describes the Standard Reference Materials (SRM's), Research Materials (RM's), and General Materials (GM's) currently distributed by the National Bureau of Standards, as well as many of the materials currently in preparation. SRM's are used to calibrate measurement systems and to provide a central basis for uniformity and accuracy of measurement. The unit and quantity, the type, and the certified characterization are listed for each SRM, as well as directions for ordering. The RM's are not certified, but are issued to meet the needs of scientists engaged in materials research. RM's are issued with a 'Report of Investigation', the sole authority of which is the author of the report. The GM's are standardized by some agency other than NBS. NBS acts only as a distribution point and does not participate in the standardization of these materials. Announcements of new and renewal SRM's, RM's and GM's are made in the semi-annual supplements of this Catalog, SRM Price List, and in scientific and trade journals

  14. Development and testing of standardized procedures and reference data for LWR surveillance

    International Nuclear Information System (INIS)

    McElroy, W.N.

    1979-02-01

    The resources and talents of many national and international organizations and laboratories, both governmental and industrial, are being used to establish analysis methods for predicting the embrittlement condition of light water reactor (LWR) primary systems. The exact interrelationships and responsibilities between those developing, understanding, combining, and applying state-of-the-art technology in dosimetry, metallurgy, and fracture mechanics for reactor systems analysis are being carefully reviewed and studied. This has resulted in a more comprehensive definition of the scope of new and updated ASTM standards required for the analysis and interpretation of LWR pressure vessel surveillance results. Fifteen new and updated ASTM standards have now been identified, together with a restructuring of the main interfaces between the individual standard practices, guides, and methods. The paper briefly discusses these standards and the initial results of multi-laboratory research work involved in their validation and calibration

  15. Preliminary results of testing bioassay analytical performance standards

    International Nuclear Information System (INIS)

    Fisher, D.R.; Robinson, A.V.; Hadley, R.T.

    1983-08-01

    The analytical performance of both in vivo and in vitro bioassay laboratories is being studied to determine the capability of these laboratories to meet the minimum criteria for accuracy and precision specified in the draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. This paper presents preliminary results of the first round of testing

  16. Polycyclic aromatic hydrocarbons (PAHs) in a coal tar standard reference material - SRM 1597a updated

    Energy Technology Data Exchange (ETDEWEB)

    Wise, Stephen A.; Poster, Dianne L.; Rimmer, Catherine A.; Schubert, Patricia; Sander, Lane C.; Schantz, Michele M. [National Institute of Standards and Technology (NIST), Analytical Chemistry Division, Gaithersburg, MD (United States); Leigh, Stefan D. [National Institute of Standards and Technology (NIST), Statistical Engineering Division, Gaithersburg, MD (United States); Moessner, Stephanie [National Institute of Standards and Technology (NIST), Analytical Chemistry Division, Gaithersburg, MD (United States); GMP/Comparator Labs, Werthenstein Chemie AG, Industrie Nord, Schachen (Switzerland)

    2010-09-15

    SRM 1597 Complex Mixture of Polycyclic Aromatic Hydrocarbons from Coal Tar, originally issued in 1987, was recently reanalyzed and reissued as SRM 1597a with 34 certified, 46 reference, and 12 information concentrations (as mass fractions) for polycyclic aromatic hydrocarbons (PAHs) and polycyclic aromatic sulfur heterocycles (PASHs) including methyl-substituted PAHs and PASHs. The certified and reference concentrations (as mass fractions) were based on results of analyses of the coal tar material using multiple analytical techniques including gas chromatography/mass spectrometry on four different stationary phases and reversed-phase liquid chromatography. SRM 1597a is currently the most extensively characterized SRM for PAHs and PASHs. (orig.)

  17. Development of a standard reference material containing 22 chlorinated hydrocarbon gases at 1 μmol/mol in nitrogen.

    Science.gov (United States)

    Li, Ning; Du, Jian; Yang, Jing; Fan, Qiang; Tian, Wen

    2017-11-01

    A gas standard mixture containing 22 chlorinated hydrocarbons in high purity nitrogen was prepared using a two-step weighing method and a gasifying apparatus developed in-house. The concentration of each component was determined using a gas chromatograph with flame ionization detection (GC/FID). Linear regression analysis of every component was performed using the gas standard mixture with concentrations ranging from 1 to 10 μmol/mol, showing the complete gasification of volatile organic compound (VOCs) species in a selected cylinder. Repeatability was also examined to ensure the reliability of the preparation method. In addition, no significant difference was observed between domestic treated and imported treated cylinders, which were conducive to reduction of the cost of raw materials. Moreover, the results of stability testing at different pressures and long-term stability tests indicated that the gas standard at 1 μmol/mol level with relative expanded uncertainties of 5% was stable above 2 MPa for a minimum of 12 months. Finally, a quantity comparison was conducted between the gas standard and a commercial gas standard from Scott Specialty Gases (now Air Liquide America Specialty Gases). The excellent agreement of every species suggested the favorable accuracy of our gas standard. Therefore, this reference material can be applied to routine observation of VOCs and for other purposes.

  18. A Reference Implementation of the OGC CSW EO Standard for the ESA HMA-T project

    Science.gov (United States)

    Bigagli, Lorenzo; Boldrini, Enrico; Papeschi, Fabrizio; Vitale, Fabrizio

    2010-05-01

    This work was developed in the context of the ESA Heterogeneous Missions Accessibility (HMA) project, whose main objective is to involve the stakeholders, namely National space agencies, satellite or mission owners and operators, in an harmonization and standardization process of their ground segment services and related interfaces. Among HMA objectives was the specification, conformance testing, and experimentation of two Extension Packages (EPs) of the ebRIM Application Profile (AP) of the OGC Catalog Service for the Web (CSW) specification: the Earth Observation Products (EO) EP (OGC 06-131) and the Cataloguing of ISO Metadata (CIM) EP (OGC 07-038). Our contributions have included the development and deployment of Reference Implementations (RIs) for both the above specifications, and their integration with the ESA Service Support Environment (SSE). The RIs are based on the GI-cat framework, an implementation of a distributed catalog service, able to query disparate Earth and Space Science data sources (e.g. OGC Web Services, Unidata THREDDS) and to expose several standard interfaces for data discovery (e.g. OGC CSW ISO AP). Following our initial planning, the GI-cat framework has been extended in order to expose the CSW.ebRIM-CIM and CSW.ebRIM-EO interfaces, and to distribute queries to CSW.ebRIM-CIM and CSW.ebRIM-EO data sources. We expected that a mapping strategy would suffice for accommodating CIM, but this proved to be unpractical during implementation. Hence, a model extension strategy was eventually implemented for both the CIM and EO EPs, and the GI-cat federal model was enhanced in order to support the underlying ebRIM AP. This work has provided us with new insights into the different data models for geospatial data, and the technologies for their implementation. The extension is used by suitable CIM and EO profilers (front-end mediator components) and accessors (back-end mediator components), that relate ISO 19115 concepts to EO and CIM ones. Moreover

  19. Validity Study of a Jump Mat Compared to the Reference Standard Force Plate.

    Science.gov (United States)

    Rogan, Slavko; Radlinger, Lorenz; Imhasly, Caroline; Kneubuehler, Andrea; Hilfiker, Roger

    2015-12-01

    In the field of vertical jump diagnostics, force plates (FP) are the reference standard. Recently, despite a lack of evidence, jump mats have been used increasingly. Important factors in favor of jumping mats are their low cost and portability. This validity study compared the Haynl-Elektronik jump mat (HE jump mat) with the reference standard force plate. Ten healthy volunteers participated and each participant completed three series of five drop jumps (DJ). The parameters ground contact time (GCT) and vertical jump height (VJH) from the HE jump mat and the FP were used to evaluate the concurrent validity. The following statistical calculations were performed: Pearson's correlation (r), Bland-Altman plots (standard and for adjusted trend), and regression equations. The Bland-Altman plots suggest that the HE jump mat measures shorter contact times and higher jump heights than the FP. The trend-adjusted Bland-Altman plot shows higher mean differences and wider wing-spreads of confidence limits during longer GCT. During the VJH the mean differences and the wing-spreads of the confidence limits throughout the range present as relatively constant. The following regression equations were created, as close as possible to the true value: GCT = 5.920385 + 1.072293 × [value HE jump mat] and VJH = -1.73777 + 1.011156 × [value HE jump mat]. The HE jump mat can be recommended in relation to the validity of constraints. In this study, only a part of the quality criteria were examined. For the final recommendation it is advised to examine the HE jump mat on the other quality criteria (test-retest reliability, sensitivity change).

  20. 41 CFR 105-735.1 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Science.gov (United States)

    2010-07-01

    ... employee ethical conduct standards, financial disclosure regulations, and other regulations. 105-735.1... CONDUCT § 105-735.1 Cross-references to employee ethical conduct standards, financial disclosure... executive branch-wide standards of ethical conduct at 5 CFR part 2635, GSA's regulations at 5 CFR part 6701...

  1. 36 CFR 400.1 - Cross-references to employees' ethical conduct standards, financial disclosure regulations and...

    Science.gov (United States)

    2010-07-01

    ...' ethical conduct standards, financial disclosure regulations and other conduct rules. 400.1 Section 400.1... CONDUCT § 400.1 Cross-references to employees' ethical conduct standards, financial disclosure regulations... executive branch-wide standards of ethical conduct and financial disclosure regulations at 5 CFR parts 2634...

  2. 29 CFR 1600.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct standards and... to employee ethical conduct standards and financial disclosure regulations. Employees of the Equal Employment Opportunity Commission (EEOC) are subject to the executive branch-wide Standards of Ethical...

  3. 36 CFR 811.1 - Cross-references to employees' ethical conduct standards, financial disclosure and financial...

    Science.gov (United States)

    2010-07-01

    ...' ethical conduct standards, financial disclosure and financial interests regulations and other conduct... EMPLOYEE RESPONSIBILITIES AND CONDUCT § 811.1 Cross-references to employees' ethical conduct standards... Council on Historic Preservation are subject to the executive branch-wide standards of ethical conduct...

  4. 24 CFR 0.1 - Cross-reference to employees ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... ethical conduct standards and financial disclosure regulations. 0.1 Section 0.1 Housing and Urban... Cross-reference to employees ethical conduct standards and financial disclosure regulations. Employees...-wide standards of ethical conduct at 5 CFR part 2635, the Department's regulation at 5 CFR part 7501...

  5. Uncertainty evaluation in normalization of isotope delta measurement results against international reference materials.

    Science.gov (United States)

    Meija, Juris; Chartrand, Michelle M G

    2018-01-01

    Isotope delta measurements are normalized against international reference standards. Although multi-point normalization is becoming a standard practice, the existing uncertainty evaluation practices are either undocumented or are incomplete. For multi-point normalization, we present errors-in-variables regression models for explicit accounting of the measurement uncertainty of the international standards along with the uncertainty that is attributed to their assigned values. This manuscript presents framework to account for the uncertainty that arises due to a small number of replicate measurements and discusses multi-laboratory data reduction while accounting for inevitable correlations between the laboratories due to the use of identical reference materials for calibration. Both frequentist and Bayesian methods of uncertainty analysis are discussed.

  6. The standardisation of trace elements in international biological standard reference materials with neutron activation analysis and atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Pieterse, H.

    1981-12-01

    An investigation was undertaken into the analytical procedures and the identification of problem areas, for the certification of a new biological standard reference material supplied by the International Atomic Energy Agency, namely, a human hair sample designated as HH-I. The analyses comprised the determination of the elements As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Sb, Se, and Zn in the hair sample by using two analytical techniques, namely, Instrumental Neutron Activation Analysis and Atomic Absorption. Three other certified biological reference materials, namely, Orchard Leaves (ORCH-L), Sea Plant Material (SPM-I) and Copepod (MAA-I) were used as control standards. Determinations were made of the moisture content of the samples, using varying conditions of drying, and the necessary corrections were applied to all analytical results so that the final elemental values related to dry weight of samples. Attention was also given to the possible loss of specific elements during ashing of the samples prior to the actual instrumental analysis. The results obtained for the hair sample by the two techniques were in good agreement for the elements Co, Fe, Mn, and Zn, but did not agree for the elements Cr and Sb. As, Hg and Se could only be determined with Instrumental Neutron Activation Analysis, and Cd, Cu and Ni only with Atomic Absorption. Most of the results obtained for the three control standard reference materials were within the ranges specified for the individual elements in each sample. The analytical procedures used for determining Cd, Cr, Cu, Ni and Sb with Instrumental Neutron Activation Analysis and As, Cr, Sb and Se with Atomic Absorption, need further investigation. The measurement of the moisture content and the ashing of samples also require further investigation with a view to improving accuracy

  7. Design and realization of the high-precision weighing systems as the gravimetric references in PTB's national water flow standard

    International Nuclear Information System (INIS)

    Engel, Rainer; Beyer, Karlheinz; Baade, Hans-Joachim

    2012-01-01

    PTB's ‘Hydrodynamic Test Field’, which represents a high-accuracy water flow calibration facility, serves as the national primary standard for liquid flow measurands. As the core reference device of this flow facility, a gravimetric standard has been incorporated, which comprises three special-design weighing systems: 300 kg, 3 tons and 30 tons. These gravimetric references were realized as a combination of a strain-gauge-based and an electromagnetic-force-compensation load-cell-based balance, each. Special emphasis had to be placed upon the dynamics design of the whole weighing system, due to the high measurement resolution and the dynamic behavior of the weighing systems, which are dynamically affected by mechanical vibrations caused by environmental impacts, flow machinery operation, flow noise in the pipework and induced wave motions in the weigh tanks. Taking into account all the above boundary conditions, the design work for the gravimetric reference resulted in a concrete foundation ‘rock’ of some 300 tons that rests on a number of vibration isolators. In addition to these passively operating vibration isolators, the vibration damping effect is enhanced by applying an electronic level regulation device. (paper)

  8. Determination of technetium-99 in environmental standard reference materials by ICP-MS

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2000-01-01

    Technetium-99 is an artificial radionuclide which is produced in the fission of 235 U or 239 Pu with a relatively high fission yield of ca. 6%. Because of its long half-life of 2.1 x 10 5 y, 99 Tc has been accumulating in the environment, and thus, is considered to present a potential risk for humans. It is important for dose assessments to identify the behavior of the nuclide in the environment. Analysis data of global fallout 99 Tc in environmental samples would give useful information for predicting the nuclide's behavior; however, due to its low concentration and analytical difficulties, not much data are available. Besides, no environmental standard reference material (SRM) for 99 Tc is available. If we could get suitable SRMs for 99 Tc analysis, it would be easier to determine the concentration of 99 Tc in environmental samples. The purpose of this study was to investigate the possibility of several SRMs to be used as references for low-level 99 Tc. For this, ICP-MS was used for 99 Tc determination. In recent years, ICP-MS has been used for 99 Tc measurements instead of radioactivity counting methods. The samples used were as follows: A) IAEA-373 (a grass sample collected on grassland near Chernobyl Nuclear Power Reactor, Ukraine), B) IAEA-375 (a soil sample collected on a field near Chernobyl Nuclear Power Reactor, Russia), C) IAEA-135 (a sea sediment sample affected by Sellafield, UK), D) five seaweed samples of which the concentration levels are different from each other (collected around the coast near Sellafield, UK). Throughout the chemical separation, 95m Tc was used as a yield monitor. The sample was incinerated for at least 2 h at 450degC. After 99 Tc extraction from the sample at 90degC for 3 h with 4M HNO 3 , the sample was filtered and the residue on the filter was washed with deionized water. The solution was diluted to ca. 0.1M HNO 3 then passed through TEVA resin column (EIChroM Industries, Inc.) to extract Tc onto the resin. Then Tc was

  9. Review of Current Standard Model Results in ATLAS

    CERN Document Server

    Brandt, Gerhard; The ATLAS collaboration

    2018-01-01

    This talk highlights results selected from the Standard Model research programme of the ATLAS Collaboration at the Large Hadron Collider. Results using data from $p-p$ collisions at $\\sqrt{s}=7,8$~TeV in LHC Run-1 as well as results using data at $\\sqrt{s}=13$~TeV in LHC Run-2 are covered. The status of cross section measurements from soft QCD processes and jet production as well as photon production are presented. The presentation extends to vector boson production with associated jets. Precision measurements of the production of $W$ and $Z$ bosons, including a first measurement of the mass of the $W$ bosons, $m_W$, are discussed. The programme to measure electroweak processes with di-boson and tri-boson final states is outlined. All presented measurements are compatible with Standard Model descriptions and allow to further constrain it. In addition they allow to probe new physics which would manifest through extra gauge couplings, or Standard Model gauge couplings deviating from their predicted value.

  10. Event-specific qualitative and quantitative detection of five genetically modified rice events using a single standard reference molecule.

    Science.gov (United States)

    Kim, Jae-Hwan; Park, Saet-Byul; Roh, Hyo-Jeong; Shin, Min-Ki; Moon, Gui-Im; Hong, Jin-Hwan; Kim, Hae-Yeong

    2017-07-01

    One novel standard reference plasmid, namely pUC-RICE5, was constructed as a positive control and calibrator for event-specific qualitative and quantitative detection of genetically modified (GM) rice (Bt63, Kemingdao1, Kefeng6, Kefeng8, and LLRice62). pUC-RICE5 contained fragments of a rice-specific endogenous reference gene (sucrose phosphate synthase) as well as the five GM rice events. An existing qualitative PCR assay approach was modified using pUC-RICE5 to create a quantitative method with limits of detection correlating to approximately 1-10 copies of rice haploid genomes. In this quantitative PCR assay, the square regression coefficients ranged from 0.993 to 1.000. The standard deviation and relative standard deviation values for repeatability ranged from 0.02 to 0.22 and 0.10% to 0.67%, respectively. The Ministry of Food and Drug Safety (Korea) validated the method and the results suggest it could be used routinely to identify five GM rice events. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Gene expression results in lipopolysaccharide-stimulated monocytes depend significantly on the choice of reference genes

    Directory of Open Access Journals (Sweden)

    Øvstebø Reidun

    2010-05-01

    Full Text Available Abstract Background Gene expression in lipopolysaccharide (LPS-stimulated monocytes is mainly studied by quantitative real-time reverse transcription PCR (RT-qPCR using GAPDH (glyceraldehyde 3-phosphate dehydrogenase or ACTB (beta-actin as reference gene for normalization. Expression of traditional reference genes has been shown to vary substantially under certain conditions leading to invalid results. To investigate whether traditional reference genes are stably expressed in LPS-stimulated monocytes or if RT-qPCR results are dependent on the choice of reference genes, we have assessed and evaluated gene expression stability of twelve candidate reference genes in this model system. Results Twelve candidate reference genes were quantified by RT-qPCR in LPS-stimulated, human monocytes and evaluated using the programs geNorm, Normfinder and BestKeeper. geNorm ranked PPIB (cyclophilin B, B2M (beta-2-microglobulin and PPIA (cyclophilin A as the best combination for gene expression normalization in LPS-stimulated monocytes. Normfinder suggested TBP (TATA-box binding protein and B2M as the best combination. Compared to these combinations, normalization using GAPDH alone resulted in significantly higher changes of TNF-α (tumor necrosis factor-alpha and IL10 (interleukin 10 expression. Moreover, a significant difference in TNF-α expression between monocytes stimulated with equimolar concentrations of LPS from N. meningitides and E. coli, respectively, was identified when using the suggested combinations of reference genes for normalization, but stayed unrecognized when employing a single reference gene, ACTB or GAPDH. Conclusions Gene expression levels in LPS-stimulated monocytes based on RT-qPCR results differ significantly when normalized to a single gene or a combination of stably expressed reference genes. Proper evaluation of reference gene stabiliy is therefore mandatory before reporting RT-qPCR results in LPS-stimulated monocytes.

  12. Preparation and certification of trace mercury in water standard reference materials

    International Nuclear Information System (INIS)

    Moody, J.R.; Paulsen, P.J.; Rains, T.C.; Rook, H.L.

    1976-01-01

    The study of mercury in natural water supplies requires a Standard Reference Material (SRM) with a certified concentration at the 1 ng/g level. NBS SRM's have been prepared with nominal mercury concentrations of 1.5 μg/g and 1.2 ng/g. Confirmation of these values was obtained by neutron activation, atomic absorption, and isotope dilution-spark source mass spectrometry (IDSSMS). Nitric acid and trace amounts of gold were added to achieve a stable mercury concentration. The precautions observed for cleaning the glass and Teflon containers, preparation of mercury solutions, and the packaging of the SRM's are given. As an example of the care needed in the analysis of mercury at these levels, specific details are presented for the chemistry required to prepare samples for the spark source mass spectrometer

  13. Crystal structure of isopropyl 2-hydroxy-2-phenylacetate: a pharmacopoeia reference standard

    Directory of Open Access Journals (Sweden)

    Ivan Isaiev

    2017-05-01

    Full Text Available The title compound, C11H14O3, is used as a pharmacopoeia reference standard for determining impurities in the drug Pregabalin, used for the treatment of epilepsy and diabetic neuropathic pain. The molecule is far from being planar, with the dihedral angle between the planes of the aromatic ring and the carboxyl fragment (O—C=O being 76.1 (6°. The isopropyl substituent is located in a synperiplanar position relative to the C=O bond and is turned so that the C—O—C—H torsion angle is −43.7°. In the crystal, bifurcated O—H...(O,O hydrogen bonds, enclosing R12(5 ring motifs, lead to the formation of chains propagating along the c-axis direction. Inversion-related chains are linked by the C—H...O hydrogen bonds, forming undulating layers lying parallel to the bc plane.

  14. New quantitative safety standards: different techniques, different results?

    International Nuclear Information System (INIS)

    Rouvroye, J.L.; Brombacher, A.C.

    1999-01-01

    Safety Instrumented Systems (SIS) are used in the process industry to perform safety functions. Many factors can influence the safety of a SIS like system layout, diagnostics, testing and repair. In standards like the German DIN no quantitative analysis is demanded (DIN V 19250 Grundlegende Sicherheitsbetrachtungen fuer MSR-Schutzeinrichtungen, Berlin, 1994; DIN/VDE 0801 Grundsaetze fuer Rechner in Systemen mit Sicherheitsaufgaben, Berlin, 1990). The analysis according to these standards is based on expert opinion and qualitative analysis techniques. New standards like the IEC 61508 (IEC 61508 Functional safety of electrical/electronic/programmable electronic safety-related systems, IEC, Geneve, 1997) and the ISA-S84.01 (ISA-S84.01.1996 Application of Safety Instrumented Systems for the Process Industries, Instrument Society of America, Research Triangle Park, 1996) require quantitative risk analysis but do not prescribe how to perform the analysis. Earlier publications of the authors (Rouvroye et al., Uncertainty in safety, new techniques for the assessment and optimisation of safety in process industry, D W. Pyatt (ed), SERA-Vol. 4, Safety engineering and risk analysis, ASME, New York 1995; Rouvroye et al., A comparison study of qualitative and quantitative analysis techniques for the assessment of safety in industry, P.C. Cacciabue, I.A. Papazoglou (eds), Proceedings PSAM III conference, Crete, Greece, June 1996) have shown that different analysis techniques cover different aspects of system behaviour. This paper shows by means of a case study, that different (quantitative) analysis techniques may lead to different results. The consequence is that the application of the standards to practical systems will not always lead to unambiguous results. The authors therefore propose a technique to overcome this major disadvantage

  15. Simultaneous Determination of Four Anthraquinones in Polygoni Multiflori Radix with Single Reference Standard by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Hua Yang

    2015-07-01

    Full Text Available Objective: To establish a rapid, accurate and reliable analytical method for the simultaneous determination of four major anthraquinones in Polygoni Multiflori Radix (PMR using single reference standard.

  16. Milk and serum standard reference materials for monitoring organic contaminants in human samples.

    Science.gov (United States)

    Schantz, Michele M; Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N Alan; Heltsley, Rebecca M; Hoover, Dale; Keller, Jennifer M; Leigh, Stefan D; Patterson, Donald G; Pintar, Adam L; Sharpless, Katherine E; Sjödin, Andreas; Turner, Wayman E; Vander Pol, Stacy S; Wise, Stephen A

    2013-02-01

    Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4'-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis.

  17. [Classification of Colombian children with malnutrition according to NCHS reference or WHO standard].

    Science.gov (United States)

    Velásquez, Claudia; Bermúdez, Juliana; Echeverri, Claudia; Estrada, Alejandro

    2011-12-01

    A descriptive study was conducted to evaluate the concordance of National Center for Health Statistics reference (NCHS) used to classify undernourished children from Colombia with the WHO Child Growth Standards. We used data from children aged 6 to 59 months with acute malnutrition (Z Infantil" nutrition program in Colombia. Indicators height-for-age, weight for-height were analyzed when they were admitted to the hospital and weight for-height leaving the hospital. A statistical method used to compare means was T-student. Correlation coefficient intraclass (CCI) and Kappa index evaluated the concordance between NCHS and OMS; McNemar method evaluated the changes on the nutritional classification for children according to growth devices used. Of the total number of children classified as normal by NCHS, 10.4% were classified as stunted by WHO. 64% of the children admitted to the hospital presented acute malnutrition according to NCHS, of these 44,8% presented severe emaciation according to OMS, indeed severe emaciation increased of 36,0% to 63,3% using OMS. 5% of children leaving the hospital could need to stay more days if they had been evaluated with OMS. Growth devices shown high concordance in height-for-age (CCI = 0,988; k= 0,866) and weight for-height (CCI = 0,901; k = 0,578). Concluded that OMS growth standards classified more malnourished children and more severe states, in addition more malnourished children could be hospitalized and they could stay more days.

  18. Implementation of Dietary Reference Intake Standards in Preschool Menus in Poland.

    Science.gov (United States)

    Myszkowska-Ryciak, Joanna; Harton, Anna

    2018-05-10

    Although the nutritional value of preschool menus largely determines the proper nutrition of attending children, their nutrient composition often does not meet the standards. The purpose of the study was to assess the nutritional value of menus served in preschools throughout Poland. We analyzed a sample of 10 daily menus and inventory reports reflecting foods and beverages served in 270 full-board government-sponsored preschools. Nutrient content was calculated per child per day, and compared with 70% of dietary reference intake (DRI) for children aged 1⁻3 and 4⁻6. The content of energy, protein, fat, and carbohydrates generally exceeded 70% of DRI. The amount of vitamins was correct, with the exception of vitamin D (100% of daycare centers (DCCs) were below the recommendations); in ≤3% of preschools vitamin E, folate, and niacin were below DRI. Calcium was too low in 63% of preschools for children aged 1⁻3 years and in 99% for 4⁻6-year-olds. A shortage of iodine, iron, and potassium (especially for 4⁻6-year-olds) was observed in a small number of preschools. Our study highlights the need for uniform legal standards of nutrition in childcare centers, based on the current recommendations for the age group.

  19. New birth weight reference standards customised to birth order and sex of babies from South India.

    Science.gov (United States)

    Kumar, Velusamy Saravana; Jeyaseelan, Lakshmanan; Sebastian, Tunny; Regi, Annie; Mathew, Jiji; Jose, Ruby

    2013-02-14

    The foetal growth standards for Indian children which are available today suffer due to methodological problems. These are, for example, not adhering to the WHO recommendation to base gestational age on the number of completed weeks and secondly, not excluding mothers with risk factors. This study has addressed both the above issues and in addition provides birthweight reference ranges with regard to sex of the baby and maternal parity. Data from the labour room register from 1996 to 2010 was obtained. A rotational sampling scheme was used i.e. the 12 months of the year were divided into 4 quadrants. All deliveries in January were considered to represent the first quadrant. Similarly all deliveries in April, July and October were considered to represent 2nd, 3rd and 4th quadrants. In each successive year different months were included in each quadrant. Only those mothers aged 20-39 years and delivered between 24 to 42 weeks gestational age were considered. Those mothers with obstetric risk factors were excluded. The reference standards were fitted using the Generalized Additive Models for Location Scale and Shape (GAMLSS) method for Box-Cox t distribution with cubic spline smoothing. There were 41,055 deliveries considered. When women with risk factors were excluded 19,501 deliveries could be included in the final analysis. The male babies of term firstborn were found to be 45 g heavier than female babies. The mean birthweights were 2934 g and 2889.5 g respectively. Similarly, among the preterm babies, the first born male babies weighed 152 g more than the female babies. The mean birthweights were 1996 g and 1844 g respectively.In the case of later born babies, the term male babies weighed 116 grams more than the females. The mean birth weights were 3085 grams and 2969 grams respectively. When considering later born preterm babies, the males outweighed the female babies by 111 grams. The mean birthweights were 2089 grams and 1978 grams

  20. 12 CFR 1401.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Cross-references to employee ethical conduct... INSURANCE CORPORATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1401.1 Cross-references to employee ethical... the Farm Credit System Insurance Corporation are subject to the Standards of Ethical Conduct for...

  1. 22 CFR 1504.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Cross-references to employee ethical conduct... FOUNDATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1504.1 Cross-references to employee ethical conduct... Foundation are subject to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR...

  2. 22 CFR 1100.1 - Cross-references to employee ethical conduct standards, financial disclosure and financial...

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Cross-references to employee ethical conduct... STATES SECTION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1100.1 Cross-references to employee ethical... executive branch standards of ethical conduct contained in 5 CFR part 2635, the executive branch financial...

  3. 12 CFR 400.101 - Cross-reference to employee financial disclosure and ethical conduct standards regulations.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Cross-reference to employee financial disclosure and ethical conduct standards regulations. 400.101 Section 400.101 Banks and Banking EXPORT-IMPORT.... Employees of the Export-Import Bank of the United States (Bank) should refer to: (a) The executive branch...

  4. New reference charts for testicular volume in Dutch children and adolescents allow the calculation of standard deviation scores

    NARCIS (Netherlands)

    Joustra, S.D.; Plas, E.M. van der; Goede, J.; Oostdijk, W.; Delemarre-van de Waal, H.A.; Hack, W.W.M.; Buuren, S. van; Wit, J.M.

    2015-01-01

    Aim Accurate calculations of testicular volume standard deviation (SD) scores are not currently available. We constructed LMS-smoothed age-reference charts for testicular volume in healthy boys. Methods The LMS method was used to calculate reference data, based on testicular volumes from

  5. 45 CFR 706.1 - Cross-references to employee ethical conduct standards, financial disclosure and financial...

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Cross-references to employee ethical conduct... 706.1 Public Welfare Regulations Relating to Public Welfare (Continued) COMMISSION ON CIVIL RIGHTS EMPLOYEE RESPONSIBILITIES AND CONDUCT § 706.1 Cross-references to employee ethical conduct standards...

  6. 77 FR 202 - Federal Acquisition Regulation; Updated Financial Accounting Standards Board Accounting References

    Science.gov (United States)

    2012-01-03

    ... 9000-AM00 Federal Acquisition Regulation; Updated Financial Accounting Standards Board Accounting... accounting standards owing to the Financial Accounting Standards Board's Accounting Standards Codification of Generally Accepted Accounting Principles. DATES: Effective Date: February 2, 2012. FOR FURTHER INFORMATION...

  7. Determination of platinum-group elements in the geological standard reference materials by isotope dilution-ICPMS

    Energy Technology Data Exchange (ETDEWEB)

    Mingyue, Hu; Hongliao, He [National Research Center for Geoanalysis, Beijing (China)

    2005-10-15

    Platinum group elements (PGEs) includes platinum, palladium, iridium, osmium, rhodium and ruthenium. It has very high economic and scientific value in the field of geoscience and environmental science. But the analysis data referred by the different lab are very disperse because of the difficulty of the determination of PGEs. It makes very difficult to fix the value of the PGEs in the standard reference materials. In the article, the values of the PGEs in the standard reference materials of ocean sediment are determined by isotope dilution technique and dependable values of these elements are provided. (authors)

  8. Determination of platinum-group elements in the geological standard reference materials by isotope dilution-ICPMS

    International Nuclear Information System (INIS)

    Hu Mingyue; He Hongliao

    2005-01-01

    Platinum group elements (PGEs) includes platinum, palladium, iridium, osmium, rhodium and ruthenium. It has very high economic and scientific value in the field of geoscience and environmental science. But the analysis data referred by the different lab are very disperse because of the difficulty of the determination of PGEs. It makes very difficult to fix the value of the PGEs in the standard reference materials. In the article, the values of the PGEs in the standard reference materials of ocean sediment are determined by isotope dilution technique and dependable values of these elements are provided. (authors)

  9. Review of neutron activation analysis in the standardization and study of reference materials, including its application to radionuclide reference materials

    International Nuclear Information System (INIS)

    Byrne, A.R.

    1993-01-01

    Neutron activation analysis (NAA) plays a very important role in the certification of reference materials (RMs) and their characterization, including homogeneity testing. The features of the method are briefly reviewed, particularly aspects relating to its completely independent nuclear basis, its virtual freedom from blank problems, and its capacity for self-verification. This last aspect, arising from the essentially isotopic character of NAA, can be exploited by using different nuclear reactions and induced nuclides, and the possibility of employing two modes, one instrumental (nondestructive), the other radiochemical (destructive). This enables the derivation of essentially independent analytical information and the unique capacity of NAA for selfvalidation. The application of NAA to quantify natural or man-made radionuclides such as uranium, thorium, 237 Np, 129 I and 230 Th is discussed, including its advantages over conventional radiometric methods and its usefulness in providing independent data for nuclides where other confirmatory analyses are impossible, or are only recently becoming available through newer 'atom counting' techniques. Certain additional, prospective uses of NAA in the study of RMs and potential RMs are mentioned, including transmutation reactions, creation of endogenously radiolabelled matrices for production and study of RMs (such as dissolution and leaching tests, use as incorporated radiotracers for chemical recovery correction), and the possibility of molecular activation analysis for specification. (orig.)

  10. Reference standard of penile size and prevalence of buried penis in Japanese newborn male infants.

    Science.gov (United States)

    Matsuo, Nobutake; Ishii, Tomohiro; Takayama, John I; Miwa, Masayuki; Hasegawa, Tomonobu

    2014-01-01

    The present study set forth the reference values for penile size and determined the prevalence of buried penis in Japanese full-term newborns. The stretched penile length was measured and the presence of buried penis was assessed at 1-7 days of age in 547 Japanese full-term newborn infants born between 2008 and 2012 in Tokyo. The stretched penile lengths were compared at 1-12 hours and 1-7 days of age in 63 infants and by two observers in 73 infants to estimate postnatal changes and interobserver variation, respectively. The mean stretched penile length was 3.06 cm (SD, 0.26; 95% confidence interval [CI], 3.04-3.08) and the mean ratio of penile length to body length was 6.24 × 100(-1) (SD, 0.55 × 100(-1)), both of which were significantly smaller than those in Caucasian newborn infants. Buried penis was identified in 20 of 547 infants (3.7%; 95% CI, 2.1-5.2%). The first measurements of penile length at 1-12 hours were significantly smaller than the next measurements at 1-7 days (95% CI of the difference, 0.22-0.34). The 95% CI for the limits of agreement in the penile lengths measured by the two observers was -0.58 to -0.40 for the lower limit and 0.33 to 0.51 for the upper limit. These findings indicate that the penile length should be assessed after 24 hours of age by the reference standard of the same ethnicity for identifying micropenis and that buried penis is not uncommon in Japanese full-term newborns.

  11. 5 CFR 1900.100 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Cross-references to employee ethical... ethical conduct standards and financial disclosure regulations. Officers and employees of the Appalachian Regional Commission Federal Staff are subject to the Standards of Ethical Conduct for Employees of the...

  12. 12 CFR 601.100 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Cross-references to employee ethical conduct... employee ethical conduct standards and financial disclosure regulations. Board members, officers, and other employees of the Farm Credit Administration are subject to the Standards of Ethical Conduct for Employees of...

  13. 5 CFR 1633.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Cross-reference to employee ethical... ethical conduct standards and financial disclosure regulations. Employees of the Federal Retirement Thrift Investment Board (Board) are subject to the executive branch-wide Standards of Ethical conduct at 5 CFR part...

  14. 29 CFR 0.735-1 - Cross-references to employee ethical conduct standards, financial disclosure regulations and...

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Cross-references to employee ethical conduct standards, financial disclosure regulations and other ethics regulations. 0.735-1 Section 0.735-1 Labor Office of the Secretary of Labor ETHICS AND CONDUCT OF DEPARTMENT OF LABOR EMPLOYEES Standards of Conduct for Current...

  15. Results of reference pricing and reimbursement discount rate schemes of Turkey

    Directory of Open Access Journals (Sweden)

    Guvenc Kockaya

    2013-06-01

    Full Text Available OBJECTIVES: General Directorate of Pharmaceuticals and Pharmacy (IEGM is responsible for setting all prices for human medicinal products. The reference pricing system is used for setting these prices. Reference countries are reviewed annually and may be subject to certain alterations. There were 5 reference countries in 2009: Spain, Italy, Germany, France and Greece. The aim of this study is to show the distribution of reference countries which were used for reference pricing.METHODS: The price list of pharmaceuticals which was published by IEGM on 15.04.2011 was used for analysis. Distribution of reference countries and prices were evaluated.RESULTS: Prices of 6,251 generic and 3,703 original products were set according to the price list. 5,283 of generics and 3,306 of originals were in the positive list for reimbursement. Reference pricing was used for 2,352 generics and 2,281 originals. Prices of the remaining were set outside of reference pricing. 32 different countries were used for reference pricing. Italy was the most popular country for reference pricing. Even if it was not a reference country, Germany was used in some of the pharmaceuticals. The average reimbursement discount rate and price were 24.43% and 249 TL, respectively. There were no colerations between price and reimbursement discount rate, or reference country and reimbursement rate.CONCLUSION: It has been shown that Italy has the highest impact on the pricing of all pharmaceuticals in Turkey. Even if it was not a reference country, Germany showed to affect pharmaceuticals more than other countries which were also not used for reference pricing. Even if reimbursement discount rates are stated by the Social Security Institution (SGK, there are different discount rates for pharmaceuticals. The analysis stated that there were correlation between price, country and discount rates. This analysis is first for the literature. Further analysis is necessary in the light of price

  16. A comparative uncertainty study of the calibration of macrolide antibiotic reference standards using quantitative nuclear magnetic resonance and mass balance methods

    International Nuclear Information System (INIS)

    Liu Shuyu; Hu Changqin

    2007-01-01

    This study introduces the general method of quantitative nuclear magnetic resonance (qNMR) for the calibration of reference standards of macrolide antibiotics. Several qNMR experimental conditions were optimized including delay, which is an important parameter of quantification. Three kinds of macrolide antibiotics were used to validate the accuracy of the qNMR method by comparison with the results obtained by the high performance liquid chromatography (HPLC) method. The purities of five common reference standards of macrolide antibiotics were measured by the 1 H qNMR method and the mass balance method, respectively. The analysis results of the two methods were compared. The qNMR is quick and simple to use. In a new medicine research and development process, qNMR provides a new and reliable method for purity analysis of the reference standard

  17. BATING A REFERENCE INSTALLATION BASED ON CONTROLLED-POTENTIAL COULOMETRY METOD IN THE FRAME OF IMPROVING THE STATE PRIMARY STANDARD GET 176 AND ITS MEASUREMENT CAPABILITIES

    Directory of Open Access Journals (Sweden)

    V. M. Zyskin

    2016-01-01

    Full Text Available The results of developing of reference installation, based on a controlled-potential coulometry, in the frame of improving the State primary standard of the units of mass (molar fraction and mass (molar concentration of a component in the liquid and solid substances and materials GET 176 are presented. The physical principles of controlled-potential coulometry, content and metrological characteristics of the developed installation are considered. Measurement results of copper, iron and lead contents in the certified reference materials of metals' solutions and CRM of brass produced by BAM, Germany, obtained using reference installation are given.

  18. New reference charts for testicular volume in Dutch children and adolescents allow the calculation of standard deviation scores.

    Science.gov (United States)

    Joustra, Sjoerd D; van der Plas, Evelyn M; Goede, Joery; Oostdijk, Wilma; Delemarre-van de Waal, Henriette A; Hack, Wilfried W M; van Buuren, Stef; Wit, Jan M

    2015-06-01

    Accurate calculations of testicular volume standard deviation (SD) scores are not currently available. We constructed LMS-smoothed age-reference charts for testicular volume in healthy boys. The LMS method was used to calculate reference data, based on testicular volumes from ultrasonography and Prader orchidometer of 769 healthy Dutch boys aged 6 months to 19 years. We also explored the association between testicular growth and pubic hair development, and data were compared to orchidometric testicular volumes from the 1997 Dutch nationwide growth study. The LMS-smoothed reference charts showed that no revision of the definition of normal onset of male puberty - from nine to 14 years of age - was warranted. In healthy boys, the pubic hair stage SD scores corresponded with testicular volume SD scores (r = 0.394). However, testes were relatively small for pubic hair stage in Klinefelter's syndrome and relatively large in immunoglobulin superfamily member 1 deficiency syndrome. The age-corrected SD scores for testicular volume will aid in the diagnosis and follow-up of abnormalities in the timing and progression of male puberty and in research evaluations. The SD scores can be compared with pubic hair SD scores to identify discrepancies between cell functions that result in relative microorchidism or macroorchidism. ©2015 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  19. Determination of non-ortho polychlorinated biphenyls in environmental Standard Reference Materials.

    Science.gov (United States)

    Brubaker, W W; Schantz, M M; Wise, S A

    2000-07-01

    The concentrations of three non-ortho ("coplanar") polychlorinated biphenyls, 3,3',4,4'-tetrachlorobiphenyl (IUPAC PCB 77), 3,3',4,4',5-pentachlorobiphenyl (IUPAC PCB 126), and 3,3',4,4',5,5'-hexachlorobiphenyl (IUPAC PCB 169), were determined in five NIST Standard Reference Materials (SRMs) of environmental and biological interest. The measured levels were approximately between (0.2 to 1.3) ng/g in SRM 1588a (Organics in Cod Liver Oil), (0.3 to 9) ng/g in SRM 1944 (New York/New Jersey Waterway Sediment), (0.2 to 0.4) ng/g in SRM 1945 (Organics in Whale Blubber), (1 to 18) ng/g in SRM 2974 (Organics in Freeze-dried Mussel Tissue [Mytilus edulis]), and (0.1 to 0.4) ng/g in candidate SRM 1946 (Lake Superior Fish Tissue). PCB 169 was present at < 0.1 ng/g in SRMs 1944 and 2974.

  20. Standard test method for determination of reference temperature, to, for ferritic steels in the transition range

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of a reference temperature, To, which characterizes the fracture toughness of ferritic steels that experience onset of cleavage cracking at elastic, or elastic-plastic KJc instabilities, or both. The specific types of ferritic steels (3.2.1) covered are those with yield strengths ranging from 275 to 825 MPa (40 to 120 ksi) and weld metals, after stress-relief annealing, that have 10 % or less strength mismatch relative to that of the base metal. 1.2 The specimens covered are fatigue precracked single-edge notched bend bars, SE(B), and standard or disk-shaped compact tension specimens, C(T) or DC(T). A range of specimen sizes with proportional dimensions is recommended. The dimension on which the proportionality is based is specimen thickness. 1.3 Median KJc values tend to vary with the specimen type at a given test temperature, presumably due to constraint differences among the allowable test specimens in 1.2. The degree of KJc variability among specimen types i...

  1. Determinants of teenage smoking, with special reference to non-standard family background.

    Science.gov (United States)

    Isohanni, M; Moilanen, I; Rantakallio, P

    1991-04-01

    The prevalence of teenage smoking in a cohort of 12,058 subjects born in northern Finland in 1966 is discussed in terms of its social and family determinants, especially in "non-standard" families (with one or more of the parents absent for at least part of the child's upbringing). The prevalence of experimental or daily smoking was 67.4%, the rate being 65.5% in the standard, two-parent families and 75.5% in the non-standard families, the difference being statistically significant (p less than 0.001). The corresponding prevalence of daily smoking was 6.4%, but the rate was 5.1% in standard families and 12.1% in non-standard families (p less than 0.001). An elevated risk of smoking existed among adolescents who had experienced death of their father or divorce of their parents and among girls who had experienced death of their mother. Maternal smoking during pregnancy and maternal age under 20 years at the time of delivery increased the risk, while being the first-born child reduced it. Among family factors existing in 1980, paternal smoking increased the risk for both sexes, while more than three siblings, mother's unemployment or gainful employment (i.e. not a housewife) were associated with smoking by the boys as was urban living, and for the girls migration by the family to a town. The results suggest that juvenile smoking may be a kind of indicator of possible problems experienced by the parents and/or the adolescents themselves with respect to parenthood and family development.

  2. Preliminary results of standard quantitative analysis by ED-XRF

    Energy Technology Data Exchange (ETDEWEB)

    Lara, Alessandro L. de; Franca, Alana C.; Neto, Manoel R.M.; Paschuk, Sergei A., E-mail: alellara@hotmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Dept. de Fisica; Denyak, Valeriy, E-mail: denyak@gmail.com [Instituto de Pesquisa Pele Pequeno Principe (IPPP), Curitiba, PR (Brazil)

    2013-07-01

    A comparison between the results of elemental concentration proposed by XRS-FP software , using data obtained by EDXRF technique with those obtained by stoichiometric calculation was performed. For this purpose, five standard samples of known compounds were produced: two lead- oxide, magnesium chloride and iodine in controlled amounts. The compounds were subsequently mixed and compressed to form tablets. The samples were irradiated in three endpoints, according to an orientation. The measurements were performed at the Laboratory for Radiological UTFPR using X-123SDD the Amptek detector and X-ray tube with silver target from the same manufacturer. The operating conditions tube were 05μA current to a 40 kV voltage. Finally, the 15 spectra analyzed with the software to determine the concentration of chlorine, iodine and lead. Data from this analysis were compared with results expected in stoichiometric calculations. The data provided by the program, a convergence of results, indicating homogeneity of the samples was found. Compared to the stoichiometric calculation, a considerable discrepancy that may be the result of a misconfiguration or contamination of the sample was found. At the end, we created a proposal for continuation of the work using an auxiliary calculation should be developed in the next step.

  3. Preliminary results of standard quantitative analysis by ED-XRF

    International Nuclear Information System (INIS)

    Lara, Alessandro L. de; Franca, Alana C.; Neto, Manoel R.M.; Paschuk, Sergei A.

    2013-01-01

    A comparison between the results of elemental concentration proposed by XRS-FP software , using data obtained by EDXRF technique with those obtained by stoichiometric calculation was performed. For this purpose, five standard samples of known compounds were produced: two lead- oxide, magnesium chloride and iodine in controlled amounts. The compounds were subsequently mixed and compressed to form tablets. The samples were irradiated in three endpoints, according to an orientation. The measurements were performed at the Laboratory for Radiological UTFPR using X-123SDD the Amptek detector and X-ray tube with silver target from the same manufacturer. The operating conditions tube were 05μA current to a 40 kV voltage. Finally, the 15 spectra analyzed with the software to determine the concentration of chlorine, iodine and lead. Data from this analysis were compared with results expected in stoichiometric calculations. The data provided by the program, a convergence of results, indicating homogeneity of the samples was found. Compared to the stoichiometric calculation, a considerable discrepancy that may be the result of a misconfiguration or contamination of the sample was found. At the end, we created a proposal for continuation of the work using an auxiliary calculation should be developed in the next step

  4. 24 CFR Appendix A to Part 200 - Standards Incorporated by Reference in the Minimum Property Standards for Housing (HUD Handbook...

    Science.gov (United States)

    2010-04-01

    ... 19103, Telephone (215) 299-5400. ASTM C 12-91 Standard Practice for Installing Vitrified Clay Pipe Lines... C 216-91c Standard Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale) ASTM.../78 77a Cast Iron Sanitary Drainage System with Hubless Pipe and Fittings—3/28/80 78 Polyethylene (PE...

  5. Standard reference radiographs for steel castings up to 2 in. (50.8 mm) in thickness

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice describes accepted procedures for and factors that influence laboratory immersion corrosion tests, particularly mass loss tests. These factors include specimen preparation, apparatus, test conditions, methods of cleaning specimens, evaluation of results, and calculation and reporting of corrosion rates. This practice also emphasizes the importance of recording all pertinent data and provides a checklist for reporting test data. Other ASTM procedures for laboratory corrosion tests are tabulated in the Appendix. (Warning-In many cases the corrosion product on the reactive metals titanium and zirconium is a hard and tightly bonded oxide that defies removal by chemical or ordinary mechanical means. In many such cases, corrosion rates are established by mass gain rather than mass loss.) 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, assoc...

  6. Reference Material Properties and Standard Problems to Verify the Fuel Performance Models Ver 1.0

    International Nuclear Information System (INIS)

    Yang, Yong Sik; Kim, Jae Yong; Koo, Yang Hyun

    2010-12-01

    All fuel performance models must be validated by in-pile and out-pile tests. However, the model validation requires much efforts and times to confirm its exactness. In many fields, new performance models and codes are confirmed by code-to-code benchmarking process under simplified standard problem analysis. At present, the DUOS, which is the steady state fuel performance analysis code for dual cooled annular fuel, development project is progressing and new FEM module is developed to analyze the fuel performance during transient period. In addition, the verification process is planning to examine the new models and module's rightness by comparing with commercial finite element analysis such as a ADINA, ABAQUS and ANSYS. This reports contains the result of unification of material properties and establishment of standard problem to verify the newly developed models with commercial FEM code

  7. A simple preparation of calibration curve standards of 134Cs and 137Cs by serial dilution of a standard reference material

    International Nuclear Information System (INIS)

    Labrecque, J.J.; Rosales, P.A.

    1990-01-01

    Two sets of calibration standards for 134 Cs and 137 Cs were prepared by small serial dilution of a natural matrix standard reference material, IAEA-154 whey powder. The first set was intended to screen imported milk powders which were suspected to be contaminated with 134 Cs and 137 Cs. Their concentration ranged from 40 to 400 Bq/kg. The other set of calibration standards was prepared to measure the environmental levels of 137 Cs in commercial Venezuelan milk powders. Their concentration ranged from 3 to 10 Bq/kg of 137 Cs. The accuracy of these calibration curves was checked by IAEA-152 and A-14 milk powders. Their measured values were in good agreement with their certified values. Finally, it is shown that these preparation techniques using serial dilution of a standard reference material were simple, rapid, precise, accurate and cost-effective. (author) 5 refs.; 5 figs.; 3 tabs

  8. Reference value standards and primary standards for pH measurements in D2O and aqueous-organic solvent mixtures: new accessions and assessments

    International Nuclear Information System (INIS)

    Mussini, P.R.; Mussini, T.; Rondinini, S.

    1997-01-01

    Recommended Reference Value Standards based on the potassium hydro-genphthalate buffer at various temperatures are reported for pH measurements in various binary solvent mixtures of water with eight organic solvents: methanol, ethanol, 2-propanol, 1,2-ethanediol, 2-methoxyethanol (''methylcellosolve''), acetonitrile, 1,4-dioxane, and dimethyl sulfoxide, together with Reference Value Standard based on the potassium deuterium phthalate buffer for pD measurements in D 2 O. In addition are reported Primary Standards for pH based on numerous buffers in various binary solvent mixtures of water with methanol, ethanol, and dimethyl sulfoxide, together with Primary Standards for pD in D 2 O based on the citrate, phosphate and carbonate buffers. (author)

  9. Measurement of the fluorine content of three NBS standard reference materials by use of the /sup 19/F(p, p'. gamma. )/sup 19/F reaction

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, A L; Kraner, H W; Shroy, R E; Jones, K W [Brookhaven National Lab., Upton, NY (USA)

    1984-08-01

    The fluorine contents of National Bureau of Standards (NBS) Standard Reference Materials (SRM) 91, opal glass; 120b, phosphate rock; and 2671a, freeze-dried urine; have been measured using the /sup 19/F(p,p'..gamma..)/sup 19/F reaction at a proton energy of 3.1 MeV. The results are in good agreement with the values certified by the NBS.

  10. MRI of the normal appendix in children: data toward a new reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Swenson, David W. [Alpert Medical School of Brown University and Rhode Island Hospital, Department of Diagnostic Imaging, Providence, RI (United States); Schooler, Gary R. [Duke University Medical Center, Department of Radiology, Durham, NC (United States); Stamoulis, Catherine; Lee, Edward Y. [Boston Children' s Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-06-15

    Magnetic resonance imaging (MRI) might prove useful in the diagnostic evaluation of pediatric appendicitis in the effort to avoid exposing children to the ionizing radiation of CT, yet there is a paucity of literature describing the normal range of appearances of the pediatric appendix on MRI. To investigate MRI characteristics of the normal appendix to aid in establishing a reference standard in the pediatric population. We conducted a retrospective study of children and young adults (≤18 years of age) who underwent lumbar spine or pelvis MRI between Jan. 1, 2013, and Dec. 31, 2013, for indications unrelated to appendicitis. Two board-certified radiologists independently reviewed all patients' MRI examinations for appendix visualization, diameter, intraluminal content signal, and presence of periappendiceal inflammation or free fluid. We used the Cohen kappa statistic and Spearman correlation coefficient to assess reader agreement on qualitative and quantitative data, respectively. Three hundred forty-six patients met inclusion criteria. Both readers visualized the appendix in 192/346 (55.5%) patients (kappa = 0.88, P < 0.0001). Estimated median appendix diameter was 5 mm for reader 1 and 6 mm for reader 2 ([25th, 75th] quartiles = [5, 6] mm; range, 2-11 mm; r = 0.81, P < 0.0001). Appendix intraluminal signal characteristics were variable. Periappendiceal inflammation was present in 0/192 (0%) and free fluid in 6/192 (3.1%) MRI examinations (kappa = 1.0). The normal appendix was seen on MRI in approximately half of pediatric patients, with a mean diameter of ∝5-6 mm, variable intraluminal signal characteristics, no adjacent inflammatory changes, and rare surrounding free fluid. (orig.)

  11. Standard and reference materials for environmental science. Part 1. Technical memo

    Energy Technology Data Exchange (ETDEWEB)

    Cantillo, A.Y.

    1995-11-01

    This is the fourth edition of the catalog of reference materials suited for use in environmental science, originally compiled in 1986 for NOAA, IOC, and UNEP. The catalog lists more than 1200 reference materials from 28 producers and contains information about their proper use, sources, availability, and analyte concentrations. Indices are included for elements, isotopes, and organic compounds, as are cross references to CAS registry numbers, alternate names, and chemical structures of selected organic compounds.

  12. Standard and reference materials for environmental science. Part 2. Technical memo

    Energy Technology Data Exchange (ETDEWEB)

    Cantillo, A.Y.

    1995-11-01

    This is the fourth edition of the catalog of reference materials suited for use in environmental science, originally compiled in 1986 for NOAA, IOC, and UNEP. The catalog lists more than 1200 reference materials from 28 producers and contains information about their proper use, sources, availability, and analyte concentrations. Indices are included for elements, isotopes, and organic compounds, as are cross references to CAS registry numbers, alternate names, and chemical structures of selected organic compounds.

  13. Quantification of the predominant monomeric catechins in baking chocolate standard reference material by LC/APCI-MS.

    Science.gov (United States)

    Nelson, Bryant C; Sharpless, Katherine E

    2003-01-29

    Catechins are polyphenolic plant compounds (flavonoids) that may offer significant health benefits to humans. These benefits stem largely from their anticarcinogenic, antioxidant, and antimutagenic properties. Recent epidemiological studies suggest that the consumption of flavonoid-containing foods is associated with reduced risk of cardiovascular disease. Chocolate is a natural cocoa bean-based product that reportedly contains high levels of monomeric, oligomeric, and polymeric catechins. We have applied solid-liquid extraction and liquid chromatography coupled with atmospheric pressure chemical ionization-mass spectrometry to the identification and determination of the predominant monomeric catechins, (+)-catechin and (-)-epicatechin, in a baking chocolate Standard Reference Material (NIST Standard Reference Material 2384). (+)-Catechin and (-)-epicatechin are detected and quantified in chocolate extracts on the basis of selected-ion monitoring of their protonated [M + H](+) molecular ions. Tryptophan methyl ester is used as an internal standard. The developed method has the capacity to accurately quantify as little as 0.1 microg/mL (0.01 mg of catechin/g of chocolate) of either catechin in chocolate extracts, and the method has additionally been used to certify (+)-catechin and (-)-epicatechin levels in the baking chocolate Standard Reference Material. This is the first reported use of liquid chromatography/mass spectrometry for the quantitative determination of monomeric catechins in chocolate and the only report certifying monomeric catechin levels in a food-based Standard Reference Material.

  14. Benefits of a Pharmacology Antimalarial Reference Standard and Proficiency Testing Program Provided by the Worldwide Antimalarial Resistance Network (WWARN)

    Science.gov (United States)

    Lourens, Chris; Lindegardh, Niklas; Barnes, Karen I.; Guerin, Philippe J.; Sibley, Carol H.; White, Nicholas J.

    2014-01-01

    Comprehensive assessment of antimalarial drug resistance should include measurements of antimalarial blood or plasma concentrations in clinical trials and in individual assessments of treatment failure so that true resistance can be differentiated from inadequate drug exposure. Pharmacometric modeling is necessary to assess pharmacokinetic-pharmacodynamic relationships in different populations to optimize dosing. To accomplish both effectively and to allow comparison of data from different laboratories, it is essential that drug concentration measurement is accurate. Proficiency testing (PT) of laboratory procedures is necessary for verification of assay results. Within the Worldwide Antimalarial Resistance Network (WWARN), the goal of the quality assurance/quality control (QA/QC) program is to facilitate and sustain high-quality antimalarial assays. The QA/QC program consists of an international PT program for pharmacology laboratories and a reference material (RM) program for the provision of antimalarial drug standards, metabolites, and internal standards for laboratory use. The RM program currently distributes accurately weighed quantities of antimalarial drug standards, metabolites, and internal standards to 44 pharmacology, in vitro, and drug quality testing laboratories. The pharmacology PT program has sent samples to eight laboratories in four rounds of testing. WWARN technical experts have provided advice for correcting identified problems to improve performance of subsequent analysis and ultimately improved the quality of data. Many participants have demonstrated substantial improvements over subsequent rounds of PT. The WWARN QA/QC program has improved the quality and value of antimalarial drug measurement in laboratories globally. It is a model that has potential to be applied to strengthening laboratories more widely and improving the therapeutics of other infectious diseases. PMID:24777099

  15. Pilot postal audits in radiotherapy for 60Co in non-reference conditions in Cuba: practical consideration and preliminary results

    International Nuclear Information System (INIS)

    Gutierrez Lores, S.; Walwyn Salas, G.; Alonso Villanueva, G.

    2008-01-01

    Discusses the practical consideration and preliminary results of the Cuban's SSDL in Pilot Postal Audit in Radiotherapy for Co-60 in non-reference conditions under IAEA Coordinated Research Project E2.40.12. A strategy for national TLD audit programmes has been developed by the international Atomic Energy Agency (IAEA). It involves progression through three sequential dosimetry audit steps. The first step audits are for the beam output in reference conditions for photon beams. The second step audits are for the dose in reference and non-reference conditions on the beam axis for photon beams. The third step audits involve measurements of the dose in reference, and non-reference conditions off-axis for open and wedged symmetric and symmetric fields for photon beams. Under coordinated research project E2.40.12 were characterized 100 micro rods. All of these rods were identified individually with a consecutive number made over one of its sides, using a fine tip of graphite. The method used to determinate the individual sensibility of the TL detectors was: irradiating a group of them, with the same history of irradiation and readout. The TLD signal was read using HARSHAW 2000C/B reader. Based on the IAEA standard TLD holder for photon beams, a TLD holder was developed with horizontal arm to enable measurements 5 cm off the central axis. Successful results in two external trial carried out using the IAEA TLD service in the years 2003 - 2004 were obtained. Five 5 facilities were considered to be included in the Pilot Audit Audits in Radiotherapy for Co-60 in non reference conditions (on-axis) in the year 2003, according to recommendation of External Audit Group (EAG). For the year 2004 were considered only 3 facilities in the Pilot Audit Audits in Radiotherapy for Co-60 in non reference conditions (off-axis). Extend the postal dose audits to the rest of the institutions around the country. The participation in these audits promotes a major understanding of the physicists

  16. Quine's Double Standard: Undermining the Indispensability Argument via the Indeterminacy of Reference

    Directory of Open Access Journals (Sweden)

    Otávio Bueno

    2003-12-01

    Full Text Available Quine has famously put forward the indispensability argument to force belief in the existence of mathematical objects (such as classes due to their indispensability to our best theories of the world (Quine 1960. Quine has also advocated the indeterminacy of reference argument, according to which reference is dramatically indeterminate: given a language, there’s no unique reference relation for that language (see Quine 1969a. In this paper, I argue that these two arguments are in conflict with each other. Whereas the indispensability argument supports realism about mathematics, the indeterminacy of reference argument, when applied to mathematics, provides a powerful strategy in support of mathematical anti-realism. I conclude the paper by indicating why the indeterminacy of reference phenomenon should be preferred over the considerations regarding indispensability. In the end, even the Quinean shouldn’t be a realist (platonist about mathematics.

  17. 46 CFR 164.023-3 - Specifications and standards incorporated by reference.

    Science.gov (United States)

    2010-10-01

    ... are: Federal Standards and Test Method Standards The following test methods in Federal Test Method Standard No. 191A, Textile Test Methods, July 20, 1978: (1) Method 4010, Length-Weight Relation; Thread..., Polyester Core: Cotton-, Rayon-, or Polyester-Covered, September 30, 1986—164.023-5. (7) MIL-T-43624A—Thread...

  18. Effective thermal conductivity of glass-fiber board and blanket standard reference materials

    International Nuclear Information System (INIS)

    Smith, D.R.; Hust, J.G.

    1983-01-01

    This chapter reports on measurements of effective thermal conductivity performed on a series of specimens of glass-fiber board and glass-fiber blanket. Explains that measurements of thermal conductivity were conducted as a function of temperature from 85 to 360 K, of temperature difference with T=10 to 100 K, of bulk density from 11 to 148 kg/m 3 and for nitrogen, argon, and helium inter-fiber fill gases at pressures from atmospheric to high vacuum. Analyzes and compares results with values from the published literature and National Bureau of Standards (NBS) certification data for similar material. Gives polynomial expressions for the functional relation between conductivity, temperature, and density for board and for blanket

  19. Standard and reference materials for marine science. Third edition. Technical memo

    International Nuclear Information System (INIS)

    Cantillo, A.Y.

    1992-08-01

    The third edition of the catalog of reference materials suited for use in marine science, originally compiled in 1986 for NOAA, IOC, and UNEP. The catalog lists close to 2,000 reference materials from sixteen producers and contains information about their proper use, sources, availability, and analyte concentrations. Indices are included for elements, isotopes, and organic compounds, as are cross references to CAS registry numbers, alternate names, and chemical structures of selected organic compounds. The catalog is being published independently by both NOAA and IOC/UNEP and is available from NOAA/NOS/ORCA in electronic form

  20. Element concentrations in candidate biological and environmental reference materials by k0-standardized INAA

    International Nuclear Information System (INIS)

    Freitas, M.C.

    1993-01-01

    K 0 -Based Neutron Activation Analysis (k 0 INAA) was used to analyze the candidate reference materials Apple Leaves and Peach Leaves, and Oriental Tobacco Leaves and Virginia Tobacco Leaves. Concentration values for 27 elements were measured. The accuracy was ascertained by analysis of two certified reference materials. NIST 1572 Citrus Leaves and 1573 Tomato Leaves. The homogeneity test of the IAEA Evernia prunastri candidate reference material in aliquots ≥ 100 mg is extended to the elements Sc, Cr, Fe, Co, Zn, Rb, Sb, Cs, Ba, Ce and Th. (orig.)

  1. Characterization of human lymphoid cell lines GM9947 and GM9948 as intra- and interlaboratory reference standards for DNA typing

    Energy Technology Data Exchange (ETDEWEB)

    Fregeau, C.J.; Elliott, J.C.; Fourney, R.M. [RCMP Central Forensic Laboratory, Ottawa, Ontario (Canada)] [and others

    1995-07-20

    The incorporation of reference DNA is crucial to the validation of any DNA typing protocol. Currently, reference DNA standards are restricted to molecular size DNA ladders and/or tumor cell line DNA. Either of these, however, presents some limitations. We have rigorously characterized two Epstein-Barr virus (EBV)-immortalized human lymphoid cell lines-GM9947 (female) and GM9948 (male)-to determine their suitability as alternative in-line standards for three widely employed allele profiling strategies. Twenty-one highly polymorphic VNTR-based allelic systems (7 RFLPs, 2 AmpFLPs, and 12 STRs) distributed over 12 chromosomes were scrutinized along with 3 gender-based discriminatory systems. The genetic stability of each locus was confirmed over a period of 225 in vitro population doublings. Allele size estimates and degree of informativeness for each of the 21 VNTR systems were compiled. The reproducibility of allele scoring by traditional RFLP analyses, using both cell lines as reference standards, was also verified by an interlaboratory validation study involving 13 analysts from two geographically distinct forensic laboratories. Taken together, our data indicate that GM9947 and GM9948 genomic DNAs could be adopted as reliable reference standards for DNA typing. 82 refs., 3 figs., 8 tabs.

  2. A NEW APPROACH FOR CULTURING LEMNA MINOR (DUCKWEED) AND STANDARDIZED METHOD FOR USING ATRAZINE AS A REFERENCE TOXICANT

    Science.gov (United States)

    Lemna minor (Duckweed) is commonly used in aquatic toxicity investigations. Methods for culturing and testing with reference toxicants, such as atrazine, are somewhat variable among researchers. Our goal was to develop standardized methods of culturing and testing for use with L....

  3. A preliminary comparative study on the content of cesium, thorium and uranium in IAEA standard reference material

    International Nuclear Information System (INIS)

    Zhang Jing; Liu Husheng; Wang Xiaoyan; Wang Naifen

    2000-01-01

    This paper presents the detection of Cs, Th and U in 6 standard reference materials provided by IAEA, using the ICP-MS method. The bismuth (Bi) was selected as internal standard element for the range compensation of matrix inhibitory effect and flow of the sensibility. The detection limit of the 3 elements was limited in the range of 0.0006∼2ng/ml, 0.4∼0.5g sample was taken and digested by acid, and detected directly by ICP-MS. The recovery of standard addition was 82.1∼100.1%

  4. Standardized Semantic Markup for Reference Terminologies, Thesauri and Coding Systems: Benefits for distributed E-Health Applications.

    Science.gov (United States)

    Hoelzer, Simon; Schweiger, Ralf K; Liu, Raymond; Rudolf, Dirk; Rieger, Joerg; Dudeck, Joachim

    2005-01-01

    With the introduction of the ICD-10 as the standard for diagnosis, the development of an electronic representation of its complete content, inherent semantics and coding rules is necessary. Our concept refers to current efforts of the CEN/TC 251 to establish a European standard for hierarchical classification systems in healthcare. We have developed an electronic representation of the ICD-10 with the extensible Markup Language (XML) that facilitates the integration in current information systems or coding software taking into account different languages and versions. In this context, XML offers a complete framework of related technologies and standard tools for processing that helps to develop interoperable applications.

  5. New quantitative safety standards : Different techniques, different results?

    NARCIS (Netherlands)

    Rouvroye, J.L.; Brombacher, A.C.; Lydersen, S.; Hansen, G.K.; Sandtor, H.

    1998-01-01

    Safety Instrumented Systems (SIS) are used in the process industry to perform safety functions. Many parameters can influence the safety of a SIS like system layout, diagnostics, testing and repair. In standards like the German DIN [DIN19250, DIN0801] no quantitative analysis was demanded. The

  6. The results of complex radiation-hygienic survey of the reference settlements in Mogilev region

    International Nuclear Information System (INIS)

    Ageeva, T.N.; Chegerova, T.I.; Shchur, A.V.; Shapsheeva, T.P.; Lipnitskij, L.V.

    2011-01-01

    The results of complex radiation-hygienic survey of the reference settlements located on the radioactively contaminated territory have been presents in the article. The four-year dynamics of the internal exposure doses of the reference settlements' inhabitants and their relationship with the 137 Cs content in foods consumed by the population have been shown. It was ascertained that there are still some isolated individuals with high doses of internal radiation among the surveyed population, which have the significant influence on the average annual radiation dose for the inhabitants and dose of its critical group. The external exposure individual doses of the inhabitants and the results of measuring of the gamma radiation dose rate in place of the settlements have been analyzed. It have been expressed the opinion about need entering adjustment in the measuring techniques of external doses. (authors)

  7. Baseline Assessment of 25-Hydroxyvitamin D Reference Material and Proficiency Testing/External Quality Assurance Material Commutability: A Vitamin D Standardization Program Study.

    Science.gov (United States)

    Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M

    2017-09-01

    The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.

  8. Occupational hazard: radiation exposure for the urologist: developing a reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Seth A.; Rangarajan, Sriram S.; Chen, Tony; Palazzi, Kerrin L.; Langford, J. Scott; Sur, Roger L., E-mail: rlsur@ucsd.edu [Department of Surgery and Division of Urology, U C San Diego Health Science System, San Diego, CA (United States)

    2013-03-15

    Introduction: to date, there is a paucity of literature offering practicing urologists a reference for the amount of radiation exposure received while surgically managing urolithiasis. This study examines the cumulative radiation exposure of an urologist over 9 months. Materials and methods: We present a case series of fluoroscopic exposures of an experienced stone surgeon operating at an academic comprehensive stone center between April and December 2011. Radiation exposure measurements were determined by a thermoluminescent dosimeter worn on the outside of the surgeon's thyroid shield. Estimations of radiation exposure (mrem) per month were charted with fluoroscopy times, using scatter plots to estimate Spearman's rank correlation coefficients. Results: the total 9-month radiation exposure was 87 mrems for deep dose equivalent (DDE), 293 mrem for lens dose equivalent (LDE), and 282 mrem for shallow dose equivalent (SDE). Total fluoroscopy time was 252.44 minutes for 64 ureteroscopies (URSs), 29 percutaneous nephrolithtomies (PNLs), 20 cystoscopies with ureteral stent placements, 9 shock wave ithotripsies (SWLs), 9 retrograde pyelograms (RPGs), 2 endoureterotomies, and 1 ureteral balloon dilation. Spearman's rank correlation coefficients examining the association between fluoroscopy time and radiation exposure were not significant for DDE (p = 0.6, Spearman's rho = 0.2), LDE (p = 0.6, Spearman's rho = 0.2), or SDE (p = 0.6, Spearman's rho = 0.2). Conclusions: Over a 9-month period, total radiation exposures were well below annual accepted limits (DDE 5000 mrem, LDE 15,000 mrem and SDE 50,000 mrem). Although fluoroscopy time did not correlate with radiation exposure, future prospective studies can account for co-variates such as patient obesity and urologist distance from radiation source. (author)

  9. Standard Test Method for Determination of the Spectral Mismatch Parameter Between a Photovoltaic Device and a Photovoltaic Reference Cell

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers a procedure for the determination of a spectral mismatch parameter used in performance testing of photovoltaic devices. 1.2 The spectral mismatch parameter is a measure of the error, introduced in the testing of a photovoltaic device, caused by mismatch between the spectral responses of the photovoltaic device and the photovoltaic reference cell, as well as mismatch between the test light source and the reference spectral irradiance distribution to which the photovoltaic reference cell was calibrated. Examples of reference spectral irradiance distributions are Tables E490 or G173. 1.3 The spectral mismatch parameter can be used to correct photovoltaic performance data for spectral mismatch error. 1.4 This test method is intended for use with linear photovoltaic devices. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, a...

  10. Determining the normal range for IGF-I, IGFBP-3, and ALS: new reference data based on current internal standards.

    Science.gov (United States)

    Ertl, Diana-Alexandra; Gleiss, Andreas; Sagmeister, Susanne; Haeusler, Gabriele

    2014-09-01

    The measurement of insulin-like growth factors (IGF-I) and insulin-like growth factor-binding protein (IGFBP-3) often serves as first-line testing in children with growth disorders. The role of acid-labile subunit (ALS) as a screening parameter for homozygous or heterozygous mutations of the ALS gene still has to be determined. IGF-I, IGFBP-3, and ALS were measured in 252 samples from children and adolescents. Reference curves were fitted using generalized additive model for location, scale and shape (GAMLSS) models and SD-Scores were calculated. Bootstrap analysis was used to quantify the uncertainty of the estimated percentiles. Bland-Altman plots were used to investigate the discrepancy between our newly estimated standard deviation scores (SDS) and SDS calculated on the basis of previous reference data. We present reference data for enzyme-linked immunosorbent assay (ELISA) measurements based on recommended internal standard for IGF-I, IGFBP-3, and ALS suitable for calculation of SD-scores. The Bland-Altman plot shows a rough agreement between the previous SDS calculation and our new one only for SDS around 1; for SDS at -2, an average difference of 0.83 SD was noticed. Our IGF-I reference values for the interval of interest in diagnosing growth hormone deficiency (GHD) (prepubertal age) are solid as proved by bootstrap analysis. The difference in calculated SD scores by using data provided previously highlights the importance of using labor and method specific reference data.

  11. [Reference values of apolipoproteins A1 and B. Contribution of international standardization. Travail collaboratif entre la SFBC, l'Arcol et le SFRL].

    Science.gov (United States)

    Steinmetz, J; Caces, E; Couderc, R; Beucler, I; Legrand, A; Henny, J

    1997-01-01

    The utilization of two WHO reference materials, liquid and lyophilized, permitted international standardization of apolipoprotein measurements. We report here the results of a collaborative study between Arcol, SFBC and SFRL in order to establish reference ranges for apo A1 and B on nine standardized systems. A population of 1027 men and women supposed healthy, 4 to 60 year old, have been selected in two Centers for Preventive Medicine. The serum samples were aliquoted frozen at -20 degrees C the day of sampling and analysed by the manufacturers with IFCC standardized calibrants. A specific quality control was performed using a frozen pool of sera. For apo A1, the centile 2.5 of the reference population varies from 1.04 to 1.16 g/l. The range values for the centile 97.5 varies from 1.87 to 2.24 g/l. For apoB, the centile 2.5 varies from 0.43 to 0.57 g/l, and the centile 97.5 from 1.30 to 1.39 g/l. Only one system has a problem of dispersion with an upper limit equal to 1.20 g/l. These results improve that international standardization allowed actually a good comparability of the results, especially for apoB.

  12. Reference and standard benchmark field consensus fission yields for U.S. reactor dosimetry programs

    International Nuclear Information System (INIS)

    Gilliam, D.M.; Helmer, R.G.; Greenwood, R.C.; Rogers, J.W.; Heinrich, R.R.; Popek, R.J.; Kellogg, L.S.; Lippincott, E.P.; Hansen, G.E.; Zimmer, W.H.

    1977-01-01

    Measured fission product yields are reported for three benchmark neutron fields--the BIG-10 fast critical assembly at Los Alamos, the CFRMF fast neutron cavity at INEL, and the thermal column of the NBS Research Reactor. These measurements were carried out by participants in the Interlaboratory LMFBR Reaction Rates (ILRR) program. Fission product generation rates were determined by post-irradiation analysis of gamma-ray emission from fission activation foils. The gamma counting was performed by Ge(Li) spectrometry at INEL, ANL, and HEDL; the sample sent to INEL was also analyzed by NaI(Tl) spectrometry for Ba-140 content. The fission rates were determined by means of the NBS Double Fission Ionization Chamber using thin deposits of each of the fissionable isotopes. Four fissionable isotopes were included in the fast neutron field measurements; these were U-235, U-238, Pu-239, and Np-237. Only U-235 was included in the thermal neutron yield measurements. For the fast neutron fields, consensus yields were determined for three fission product isotopes--Zr-95, Ru-103, and Ba-140. For these fission product isotopes, a separately activated foil was analyzed by each of the three gamma counting laboratories. The experimental standard deviation of the three independent results was typically +- 1.5%. For the thermal neutron field, a consensus value for the Cs-137 yield was also obtained. Subsidiary fission yields are also reported for other isotopes which were studied less intensively (usually by only one of the participating laboratories). Comparisons with EBR-II fast reactor yields from destructive analysis and with ENDF/B recommended values are given

  13. Uncertainty Analysis of Spectral Irradiance Reference Standards Used for NREL Calibrations

    Energy Technology Data Exchange (ETDEWEB)

    Habte, A.; Andreas, A.; Reda, I.; Campanelli, M.; Stoffel, T.

    2013-05-01

    Spectral irradiance produced by lamp standards such as the National Institute of Standards and Technology (NIST) FEL-type tungsten halogen lamps are used to calibrate spectroradiometers at the National Renewable Energy Laboratory. Spectroradiometers are often used to characterize spectral irradiance of solar simulators, which in turn are used to characterize photovoltaic device performance, e.g., power output and spectral response. Therefore, quantifying the calibration uncertainty of spectroradiometers is critical to understanding photovoltaic system performance. In this study, we attempted to reproduce the NIST-reported input variables, including the calibration uncertainty in spectral irradiance for a standard NIST lamp, and quantify uncertainty for measurement setup at the Optical Metrology Laboratory at the National Renewable Energy Laboratory.

  14. NASA/NBS (National Aeronautics and Space Administration/National Bureau of Standards) standard reference model for telerobot control system architecture (NASREM)

    Science.gov (United States)

    Albus, James S.; Mccain, Harry G.; Lumia, Ronald

    1989-01-01

    The document describes the NASA Standard Reference Model (NASREM) Architecture for the Space Station Telerobot Control System. It defines the functional requirements and high level specifications of the control system for the NASA space Station document for the functional specification, and a guideline for the development of the control system architecture, of the 10C Flight Telerobot Servicer. The NASREM telerobot control system architecture defines a set of standard modules and interfaces which facilitates software design, development, validation, and test, and make possible the integration of telerobotics software from a wide variety of sources. Standard interfaces also provide the software hooks necessary to incrementally upgrade future Flight Telerobot Systems as new capabilities develop in computer science, robotics, and autonomous system control.

  15. The development and certification of Standard Reference Materials (SRMs) to assess and ensure accurate measurement of Pb in the environment.

    Science.gov (United States)

    Fassett, J D; MacDonald, B S

    2001-08-01

    The National Institute of Standards and Technology (NIST) has had a major quality-assurance role in the federal effort to reduce lead poisoning of children in the United States through its mission of ensuring the accuracy of chemical measurements. NIST certifies reference materials (standard reference materials--SRMs) that are used to benchmark measurements by secondary and field methods of analysis--to ensure that decisions of great health and economic impact are soundly based on good measurement science. Over the past 10 years, in cooperation with the US Environmental Protection Agency (EPA), US Department of Housing and Urban Development (HUD), and the United States Geological Survey (USGS), NIST has prepared and certified SRMs for lead content in soil, indoor dust, and paint. The role of these materials in meeting regulatory and abatement needs is described and their certified values are summarized.

  16. The determination, by instrumental neutron-activation analysis, of some elements in the NIMROC standard reference materials

    International Nuclear Information System (INIS)

    Eddy, B.T.; Pearton, D.C.G.; Bibby, D.M.

    1975-01-01

    Instrumental neutron-activation analysis was used for the determination of sixteen trace and minor elements in the six NIMROC reference materials. Six reference rock materials prepared by the U.S. Geological Survey were also analysed, and the results were compared with the recommended, average, or magnitude values given for these rocks by Flanagan. The agreement between the two sets of results was found to be generally good, indicating that INAA is an acceptable technique for the determination of most of these elements. The values found for the NIMROC samples represent a significant contribution to the evaluation of the trace elements in these reference materials [af

  17. Thermal conductivity and electrical resistivity standard reference materials: tungsten SRM's 730 and 799, from 4 to 30000K. Final report

    International Nuclear Information System (INIS)

    Hust, J.G.; Giarratano, P.J.

    1975-09-01

    A historical review of the development of thermophysical Standard Reference Materials, SRM's, is given and selection criteria of SRM's are listed. Thermal conductivity and electrical resistivity data for arc cast and sintered tungsten are compiled, analyzed, and correlated. Recommended values of thermal conductivity (SRM 730) and electrical resistivity (SRM 799) for these lots of tungsten are presented for the range 4 to 3000 0 K

  18. Safety evaluation report related to the preliminary design of the Standard Reference System, RESAR-414

    International Nuclear Information System (INIS)

    1978-11-01

    The safety evaluation for the Westinghouse Standard Reactor includes information on general reactor characteristics; design criteria for systems and components; reactor coolant system; engineered safety systems; instrumentation and controls; electric power systems; auxiliary systems; steam and power conversion system; radioactive waste management; radiation protection; conduct of operations; accident analyses; and quality assurance

  19. 77 FR 751 - Federal Motor Vehicle Safety Standards; Matters Incorporated by Reference

    Science.gov (United States)

    2012-01-06

    ... Recommended Practice J1133, ``School Bus Stop Arm,'' revised April 1984, into Sec. 571.131. (45) SAE Standard... constriction requirement of S5.3.1 after having been subjected to a temperature of 248 degrees Fahrenheit (120... mandatory requirements. * * * * * S6.4.5 School bus signal lamp aiming. Each school bus signal lamp must be...

  20. 75 FR 48593 - Pipeline Safety: Periodic Updates of Regulatory References to Technical Standards and...

    Science.gov (United States)

    2010-08-11

    ... (ASTM): ASTM A53/A53M-07 (2007), ``Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless'' (September 1, 2007). Replaces IBR: 2004 edition; Referenced in 49 CFR 192...), we clarify that cast iron, malleable iron, or ductile iron may be used in the valve ball or plug...

  1. Relation of structure to function for the US reference standard endotoxin after exposure to 60Co radiation

    International Nuclear Information System (INIS)

    Csako, G.; Suba, E.A.; Ahlgren, A.; Tsai, C.M.; Elin, R.J.

    1986-01-01

    The structure and function of the highly purified US reference standard endotoxin (RSE) were studied after exposure to ionizing radiation from a 60 Co source. With increasing doses of radiation, the trilaminar ribbon-like structure of untreated endotoxin exhibited focal swelling, after which only spherical particles were seen by electron microscopy. These morphological changes were paralleled by the respective loss of O-side chain repeating units and pieces of the R-core from the lipopolysaccharide molecules, as demonstrated by electrophoresis. The biologic function of the irradiated endotoxin was assessed with a variety of tests. At higher doses of radiation, a direct relation was observed between the degradation of the molecular and supramolecular structure and the loss of biologic function. At lower doses of radiation, however, there was variability among the functional assays in their rate of change with progressive irradiation of the RSE. The results suggest that the carbohydrate moiety plays an important role both in determining the supramolecular structure and in modulating certain biologic activities of bacterial endotoxins

  2. A Standard Mammography Unit - Standard 3D Ultrasound Probe Fusion Prototype: First Results.

    Science.gov (United States)

    Schulz-Wendtland, Rüdiger; Jud, Sebastian M; Fasching, Peter A; Hartmann, Arndt; Radicke, Marcus; Rauh, Claudia; Uder, Michael; Wunderle, Marius; Gass, Paul; Langemann, Hanna; Beckmann, Matthias W; Emons, Julius

    2017-06-01

    The combination of different imaging modalities through the use of fusion devices promises significant diagnostic improvement for breast pathology. The aim of this study was to evaluate image quality and clinical feasibility of a prototype fusion device (fusion prototype) constructed from a standard tomosynthesis mammography unit and a standard 3D ultrasound probe using a new method of breast compression. Imaging was performed on 5 mastectomy specimens from patients with confirmed DCIS or invasive carcinoma (BI-RADS ™ 6). For the preclinical fusion prototype an ABVS system ultrasound probe from an Acuson S2000 was integrated into a MAMMOMAT Inspiration (both Siemens Healthcare Ltd) and, with the aid of a newly developed compression plate, digital mammogram and automated 3D ultrasound images were obtained. The quality of digital mammogram images produced by the fusion prototype was comparable to those produced using conventional compression. The newly developed compression plate did not influence the applied x-ray dose. The method was not more labour intensive or time-consuming than conventional mammography. From the technical perspective, fusion of the two modalities was achievable. In this study, using only a few mastectomy specimens, the fusion of an automated 3D ultrasound machine with a standard mammography unit delivered images of comparable quality to conventional mammography. The device allows simultaneous ultrasound - the second important imaging modality in complementary breast diagnostics - without increasing examination time or requiring additional staff.

  3. U.S. Department of Energy Reference Model Program RM1: Experimental Results

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Craig [Univ. of Minnesota, Minneapolis, MN (United States); Neary, Vincent Sinclair [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gunawan, Budi [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Guala, Michele [Univ. of Minnesota, Minneapolis, MN (United States); Sotiropoulos, Fotis [Univ. of Minnesota, Minneapolis, MN (United States)

    2014-10-01

    The Reference Model Project (RMP), sponsored by the U.S. Department of Energy’s (DOE) Wind and Water Power Technologies Program within the Office of Energy Efficiency & Renewable Energy (EERE), aims at expediting industry growth and efficiency by providing non-proprietary Reference Models (RM) of MHK technology designs as study objects for open-source research and development (Neary et al. 2014a,b). As part of this program, MHK turbine models were tested in a large open channel facility at the University of Minnesota’s St. Anthony Falls Laboratory (UMN-SAFL). Reference Model 1 (RM2) is a 1:40 geometric scale dual-rotor axial flow horizontal axis device with counter-rotating rotors, each with a rotor diameter dT = 0.5m. Precise blade angular position and torque measurements were synchronized with three acoustic Doppler velocimeters (ADVs) aligned with each rotor and the midpoint for RM1. Flow conditions for each case were controlled such that depth, h = 1m, and volumetric flow rate, Qw = 2.425m3s-1, resulting in a hub height velocity of approximately Uhub = 1.05ms-1 and blade chord length Reynolds numbers of Rec ≈ 3.0x105. Vertical velocity profiles collected in the wake of each device from 1 to 10 rotor diameters are used to estimate the velocity recovery and turbulent characteristics in the wake, as well as the interaction of the counter-rotating rotor wakes. The development of this high resolution laboratory investigation provides a robust dataset that enables assessing turbulence performance models and their ability to accurately predict device performance metrics, including computational fluid dynamics (CFD) models that can be used to predict turbulent inflow environments, reproduce wake velocity deficit, recovery and higher order turbulent statistics, as well as device performance metrics.

  4. U.S. Department of Energy Reference Model Program RM1: Experimental Results.

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Craig [Univ. of Minnesota, Minneapolis, MN (United States); Neary, Vincent Sinclair [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gunawan, Budi [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Guala, Michele [Univ. of Minnesota, Minneapolis, MN (United States); Sotiropoulos, Fotis [Univ. of Minnesota, Minneapolis, MN (United States)

    2017-08-01

    The Reference Model Project (RMP), sponsored by the U.S. Department of Energy’s (DOE) Wind and Water Power Technologies Program within the Office of Energy Efficiency & Renewable Energy (EERE), aims at expediting industry growth and efficiency by providing nonproprietary Reference Models (RM) of MHK technology designs as study objects for opensource research and development (Neary et al. 2014a,b). As part of this program, MHK turbine models were tested in a large open channel facility at the University of Minnesota’s St. Anthony Falls Laboratory (UMN-SAFL). Reference Model 1 (RM1) is a 1:40 geometric scale dual-rotor axial flow horizontal axis device with counter-rotating rotors, each with a rotor diameter dT = 0.5m. Precise blade angular position and torque measurements were synchronized with three acoustic Doppler velocimeters (ADVs) aligned with each rotor and the midpoint for RM1. Flow conditions for each case were controlled such that depth, h = 1m, and volumetric flow rate, Qw = 2.425m3s-1, resulting in a hub height velocity of approximately Uhub = 1.05ms-1 and blade chord length Reynolds numbers of Rec ≈ 3.0x105. Vertical velocity profiles collected in the wake of each device from 1 to 10 rotor diameters are used to estimate the velocity recovery and turbulent characteristics in the wake, as well as the interaction of the counter-rotating rotor wakes. The development of this high resolution laboratory investigation provides a robust dataset that enables assessing turbulence performance models and their ability to accurately predict device performance metrics, including computational fluid dynamics (CFD) models that can be used to predict turbulent inflow environments, reproduce wake velocity deficit, recovery and higher order turbulent statistics, as well as device performance metrics.

  5. Preparation and evaluation of reference materials for accountancy analysis. (2) Evaluation results

    International Nuclear Information System (INIS)

    Sumi, Mika; Abe, Katsuo; Kageyama, Tomio; Nakazawa, Hiroaki; Takamatsu, Mai; Kacchi, Tomokazu; Murakami, Toshiki; Ai, Hironobu

    2009-01-01

    Destructive analysis for accountancy at nuclear fuel facilities should attain international target values for measurement uncertainties in safeguarding nuclear materials (ITVs). Since measurement uncertainties of isotope dilution mass spectrometry depend on uncertainties of spikes (standard materials) used, utilizing highly reliable standard material is essential. The LSD spikes prepared under collaboration work with JAEA and JNFL has different Pu/U ratio and smaller nuclear material in a spike compared with the LSD spikes used a safeguard laboratories, and the value of Pu which separated and purified from MOX and used as raw material for one of the LSD spike prepared at JAEA were measured at JAEA. Uncertainties of the prepared LSD spikes and the measurement results of actual samples with these LSD spikes were evaluated based on ISO-GUM and compared with ITVs. (author)

  6. Determinations of silicon and phosphorus in Pepperbush standard reference material by neutron activation and x-ray fluorescence methods

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Nishio, Hirofumi; Hayashi, Takeshi; Kusakabe, Toshio; Iwata, Shiro.

    1987-01-01

    Silicon and phosphorus contents in Pepperbush standard reference material were determined by neutron activation and X-ray fluorescence methods. In neutron activation analysis, β-ray spectra of 32 P produced by 31 P(n,γ) 32 P reaction on Pepperbush and standard samples were measured by a low background β-ray spectrometer. In X-ray fluorescence analysis, the standard samples were prepared by mixing the Pepperbush powder with silicon dioxide and diammonium hydrogenphosphate. Characteristic X-rays from the samples were analyzed by a wavelength dispersive X-ray fluorescence spectrometer. From the β and X-ray intensities, silicon and phosphorus contents in Pepperbush were determined to be 1840 ± 80 and 1200 ± 50 μg g -1 , respectively. (author)

  7. Development of liquid chromatographic methods for the determination of phytosterols in Standard Reference Materials containing saw palmetto.

    Science.gov (United States)

    Bedner, Mary; Schantz, Michele M; Sander, Lane C; Sharpless, Katherine E

    2008-05-23

    Liquid chromatographic (LC) methods using atmospheric pressure chemical ionization/mass spectrometric (APCI-MS) detection were developed for the separation and analysis of the phytosterols campesterol, cycloartenol, lupenone, lupeol, beta-sitosterol, and stigmasterol. Brassicasterol and cholesterol were also included for investigation as internal standards. The methods were used to identify and quantify the phytosterols in each of two Serenoa repens (saw palmetto) Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST). Values obtained by LC-MS were compared to those obtained using the more traditional approach of gas chromatography with flame ionization detection. This is the first reported use of LC-MS to determine phytosterols in saw palmetto dietary supplement materials.

  8. A contemporary Colombian skeletal reference collection: A resource for the development of population specific standards.

    Science.gov (United States)

    Sanabria-Medina, Cesar; González-Colmenares, Gretel; Restrepo, Hadaluz Osorio; Rodríguez, Juan Manuel Guerrero

    2016-09-01

    Several authors who have discussed human variability and its impact on the forensic identification of bodies pose the need for regional studies documenting the global variation of the attributes analyzed osteological characteristics that aid in establishing biological profile (sex, ancestry, biological age and height). This is primarily accomplished by studying documented human skeletal collections in order to investigate secular trends in skeletal development and aging, among others in the Colombian population. The purpose of this paper is to disclose the details of the new "Contemporary Colombian Skeletal Reference Collection" that currently comprises 600 identified skeletons of both sexes, who died between 2005 and 2008; and which contain information about their cause of death. This collection has infinite potential for research, open to the national and international community, and still has pending opportunities to address a variety of topics such as studies on osteopathology, bone trauma and taphonomic studies. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Determination of reference intervals and comparison of venous blood gas parameters using standard and non-standard collection methods in 24 cats.

    Science.gov (United States)

    Bachmann, Karin; Kutter, Annette Pn; Schefer, Rahel Jud; Marly-Voquer, Charlotte; Sigrist, Nadja

    2017-08-01

    Objectives The aim of this study was to determine in-house reference intervals (RIs) for venous blood analysis with the RAPIDPoint 500 blood gas analyser using blood gas syringes (BGSs) and to determine whether immediate analysis of venous blood collected into lithium heparin (LH) tubes can replace anaerobic blood sampling into BGSs. Methods Venous blood was collected from 24 healthy cats and directly transferred into a BGS and an LH tube. The BGS was immediately analysed on the RAPIDPoint 500 followed by the LH tube. The BGSs and LH tubes were compared using paired t-test or Wilcoxon matched-pairs signed-rank test, Bland-Altman and Passing-Bablok analysis. To assess clinical relevance, bias or percentage bias between BGSs and LH tubes was compared with the allowable total error (TEa) recommended for the respective parameter. Results Based on the values obtained from the BGSs, RIs were calculated for the evaluated parameters, including blood gases, electrolytes, glucose and lactate. Values derived from LH tubes showed no significant difference for standard bicarbonate, whole blood base excess, haematocrit, total haemoglobin, sodium, potassium, chloride, glucose and lactate, while pH, partial pressure of carbon dioxide and oxygen, actual bicarbonate, extracellular base excess, ionised calcium and anion gap were significantly different to the samples collected in BGSs ( P glucose and lactate can be made based on blood collected in LH tubes and analysed within 5 mins. For pH, partial pressure of carbon dioxide and oxygen, extracellular base excess, anion gap and ionised calcium the clinically relevant alterations have to be considered if analysed in LH tubes.

  10. Impact of a product-specific reference standard for the measurement of a PEGylated rFVIII activity: the Swiss Multicentre Field Study.

    Science.gov (United States)

    Bulla, O; Poncet, A; Alberio, L; Asmis, L M; Gähler, A; Graf, L; Nagler, M; Studt, J-D; Tsakiris, D A; Fontana, P

    2017-07-01

    Measuring factor VIII (FVIII) activity can be challenging when it has been modified, such as when FVIII is pegylated to increase its circulating half-life. Use of a product-specific reference standard may help avoid this issue. Evaluate the impact of using a product-specific reference standard for measuring the FVIII activity of BAX 855 - a pegylated FVIII - in eight of Switzerland's main laboratories. Factor VIII-deficient plasma, spiked with five different concentrations of BAX 855, plus a control FVIII sample, was sent to the participating laboratories. They measured FVIII activity by using either with a one-stage (OSA) or the chromogenic assay (CA) against their local or a product-specific reference standard. When using a local reference standard, there was an overestimation of BAX 855 activity compared to the target concentrations, both with the OSA and CA. The use of a product-specific reference standard reduced this effect: mean recovery ranged from 127.7% to 213.5% using the OSA with local reference standards, compared to 110% to 183.8% with a product-specific reference standard, and from 146.3% to 182.4% using the CA with local reference standards compared to 72.7% to 103.7% with a product-specific reference standard. In this in vitro study, the type of reference standard had a major impact on the measurement of BAX 855 activity. Evaluation was more accurate and precise when using a product-specific reference standard. © 2017 John Wiley & Sons Ltd.

  11. Body mass index in Saudi Arabian children and adolescents: A national reference and comparison with international standards

    International Nuclear Information System (INIS)

    Al Herbish, Abdullah S; ElMouzan, Mohammed I; AlSalloum, Abdullah A; AlQureshi, Mansour M; AlOmar, Ahmed A; Fster, Peter J; Kecojevic, Tatjana

    2009-01-01

    Because there are no reference standards for body mass index (BMI) in Saudi children, we established BMI reference percentiles for normal Saudi Arabian children and adolescents and compared them with international standards. Data from a stratified multistage probability sample were collected from the 13 health regions in Saudi Arabia, as part of a nationwide health profile survey of Saudi Arabian children and adolescents conducted to establish normal physical growth references. Selected households were visited by a trained team. Weight and length/height were measured and recorded following the WHO recommended procedures using the same equipment, which were subjected to both calibration and intra/interobserver variations. Survey of 11 874 eligible households yielded 35 275 full-term and healthy children and adolescents who were subjected to anthropometric measurements. Four BMI curves were produced, from birth to 36 months and 2 to 19 years for girls and boys. The 3rd, 5th, 10th ,25th , 5oth , 75th ,85th , 90th , 95th , and 97th percentiles were produced and compared with the WHO and CDC BMI charts. In the higher percentiles, the Saudi children differed from Western counterparts, indicating that Saudi children have equal or higher BMIs. The BMI curves reflect statistically representative BMI values for Saudi Arabian children and adolescents. (author)

  12. Absolute Salinity, ''Density Salinity'' and the Reference-Composition Salinity Scale: present and future use in the seawater standard TEOS-10

    Science.gov (United States)

    Wright, D. G.; Pawlowicz, R.; McDougall, T. J.; Feistel, R.; Marion, G. M.

    2011-01-01

    oceanography. The other two salinity variables provide alternative measures of the mass fraction of dissolved material in seawater. "Solution Salinity", denoted SAsoln, is the most obvious extension of Reference Salinity to allow for composition anomalies; it provides a direct estimate of the mass fraction of dissolved material in solution. "Added-Mass Salinity", denoted SAadd, is motivated by a method used to report laboratory experiments; it represents the component of dissolved material added to Standard Seawater in terms of the mass of material before it enters solution. We also discuss a constructed conservative variable referred to as "Preformed Salinity", denoted S∗, which will be useful in process-oriented numerical modelling studies. Finally, a conceptual framework for the incorporation of composition anomalies in numerical models is presented that builds from studies in which composition anomalies are simply ignored up to studies in which the influences of composition anomalies are accounted for using the results of biogeochemical models. 1TEOS-10: international Thermodynamic Equation of Seawater 2010, http://www.teos-10.org/.

  13. Absolute Salinity, "Density Salinity" and the Reference-Composition Salinity Scale: present and future use in the seawater standard TEOS-10

    Science.gov (United States)

    Wright, D. G.; Pawlowicz, R.; McDougall, T. J.; Feistel, R.; Marion, G. M.

    2010-08-01

    oceanography. The other two salinity variables provide alternative measures of the mass fraction of dissolved material in seawater. "Solution Salinity", denoted SAsoln, is the most obvious extension of Reference Salinity to allow for composition anomalies; it provides a direct estimate of the mass fraction of dissolved material in solution. "Added-Mass Salinity", denoted SAadd, is motivated by a method used to report laboratory experiments; it represents the component of dissolved material added to Standard Seawater in terms of the mass of material before it enters solution. We also discuss a constructed conservative variable referred to as "Preformed Salinity", denoted S*, which will be useful in process-oriented numerical modelling studies. Finally, a conceptual framework for the incorporation of composition anomalies in numerical models is presented that builds from studies in which composition anomalies are simply ignored up to studies in which the influences of composition anomalies are accounted for using the results of biogeochemical models. 1TEOS-10: international thermodynamic equation of seawater 2010, http://www.teos-10.org.

  14. Absolute Salinity, ''Density Salinity'' and the Reference-Composition Salinity Scale: present and future use in the seawater standard TEOS-10

    Directory of Open Access Journals (Sweden)

    D. G. Wright

    2011-01-01

    >SAdens; it stands out as the most appropriate representation of salinity for use in dynamical physical oceanography. The other two salinity variables provide alternative measures of the mass fraction of dissolved material in seawater. "Solution Salinity", denoted SAsoln, is the most obvious extension of Reference Salinity to allow for composition anomalies; it provides a direct estimate of the mass fraction of dissolved material in solution. "Added-Mass Salinity", denoted SAadd, is motivated by a method used to report laboratory experiments; it represents the component of dissolved material added to Standard Seawater in terms of the mass of material before it enters solution. We also discuss a constructed conservative variable referred to as "Preformed Salinity", denoted S, which will be useful in process-oriented numerical modelling studies.

    Finally, a conceptual framework for the incorporation of composition anomalies in numerical models is presented that builds from studies in which composition anomalies are simply ignored up to studies in which the influences of composition anomalies are accounted for using the results of biogeochemical models.

    1TEOS-10: international Thermodynamic Equation of Seawater 2010, http://www.teos-10.org/.

  15. Carcinoma of rubor labiorum - assessment of results with particular reference to treatment with X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Wojcieszek, Z; Krzyszkowska, W [Instytut Onkologii, Gliwice (Poland)

    1976-11-01

    In the years 1962-1966 225 patients with carcinoma of the rubor labiorum were observed in the Institute of Oncology in Gliwice. The patients were treated surgically or with X-rays. In the group of 204 treated patients the 5-year survival rate was 86% without signs of recurrence (after taking into consideration the natural mortality in the population). Advanced cases were treated mostly with X-rays. Evaluation of nominal standard dose on tissues showed best results in the group in which this dose was about 1700 r.

  16. A Proposal of New Reference System for the Standard Axial, Sagittal, Coronal Planes of Brain Based on the Serially-Sectioned Images

    Science.gov (United States)

    Park, Jin Seo; Park, Hyo Seok; Shin, Dong Sun; Har, Dong-Hwan; Cho, Zang-Hee; Kim, Young-Bo; Han, Jae-Yong; Chi, Je-Geun

    2010-01-01

    Sectional anatomy of human brain is useful to examine the diseased brain as well as normal brain. However, intracerebral reference points for the axial, sagittal, and coronal planes of brain have not been standardized in anatomical sections or radiological images. We made 2,343 serially-sectioned images of a cadaver head with 0.1 mm intervals, 0.1 mm pixel size, and 48 bit color and obtained axial, sagittal, and coronal images based on the proposed reference system. This reference system consists of one principal reference point and two ancillary reference points. The two ancillary reference points are the anterior commissure and the posterior commissure. And the principal reference point is the midpoint of two ancillary reference points. It resides in the center of whole brain. From the principal reference point, Cartesian coordinate of x, y, z could be made to be the standard axial, sagittal, and coronal planes. PMID:20052359

  17. Mercury Trapped Ion Frequency Standard for Ultra-Stable Reference Applications

    Science.gov (United States)

    Burt, Eric A. (Inventor); Hamell, Robert L. (Inventor); Tucker, Blake C. (Inventor); Larsen, Kameron (Inventor); Tjoelker, Robert L. (Inventor)

    2017-01-01

    An atomic clock including an ion trap assembly, a C-field coil positioned for generating a first magnetic field in the interrogation region of the ion trap assembly, a compensation coil positioned for generating a second magnetic field in the interrogation region, wherein the combination of the first and second magnetic fields produces an ion number-dependent second order Zeeman shift (Zeeman shift) in the resonance frequency that is opposite in sign to an ion number-dependent second order Doppler shift (Doppler shift) in the resonance frequency, the C-field coil has a radius selected using data indicating how changes in the radius affect an ion-number-dependent shift in the resonance frequency, such that a difference in magnitude between the Doppler shift and the Zeeman shift is controlled or reduced, and the resonance frequency, including the adjustment by the Zeeman shift, is used to obtain the frequency standard.

  18. [Personalizing the reference level: gold standard to evaluate the quality of service perceived].

    Science.gov (United States)

    Rodrigo-Rincón, I; Reyes-Pérez, M; Martínez-Lozano, M E

    2014-01-01

    To know the cutoff point at which in-house Nuclear Medicine Department (MND) customers consider that the quality of service is good (personalized cutoff). We conducted a survey of the professionals who had requested at least 5 tests to the Nuclear Medicine Department. A total of 71 doctors responded (response rate: 30%). A question was added to the questionnaire for the user to establish a cutoff point for which they would consider the quality of service as good. The quality non-conformities, areas of improvement and strong points of the six questions measuring the quality of service (Likert scale 0 to 10) were compared with two different thresholds: personalized cutoff and one proposed by the service itself a priori. Test statistics: binomial and Student's t-test for paired data. A cutoff value of 7 was proposed by the service as a reference while 68.1% of respondents suggested a cutoff above 7 points (mean 7.9 points). The 6 elements of perceived quality were considered strong points with the cutoff proposed by the MND, while there were 3 detected with the personalized threshold. Thirteen percent of the answers were nonconformities with the service cutoff versus 19.2% with the personalized one, the differences being statistically significant (difference 95% CI 6.44%:0,83-12.06). The final image of the perceived quality of an in-house customer is different when using the cutoff established by the Department versus the personalized cutoff given by the respondent. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  19. Simultaneous determination of theobromine, (+)-catechin, caffeine, and (-)-epicatechin in standard reference material baking chocolate 2384, cocoa, cocoa beans, and cocoa butter.

    Science.gov (United States)

    Risner, Charles H

    2008-01-01

    A reverse-phase liquid chromatography analysis is used to access the quantity of theobromine, (+)-catechin, caffeine, and (-)-epicatechin in Standard Reference Material 2384 Baking Chocolate, cocoa, cocoa beans, and cocoa butter using water or a portion of the mobile phase as the extract. The procedure requires minimal sample preparation. Theobromine, (+)-catechin, caffeine, and (-)-epicatechin are detected by UV absorption at 273 nm after separation using a 0.3% acetic acid-methanol gradient (volume fractions) and quantified using external standards. The limit of detection for theobromine, (+)-catechin, caffeine, and (-)-epicatechin averages 0.08, 0.06, 0.06, and 0.06 microg/mL, respectively. The method when applied to Standard Reference Material 2384 Baking Chocolate; baking chocolate reference material yields results that compare to two different, separate procedures. Theobromine ranges from 26000 mg/kg in cocoa to 140 mg/kg in cocoa butter; (+)-catechin from 1800 mg/kg in cocoa to below detection limits of theobromine, 100.0 +/- 0.6 for (+)-catechin, 96.2 +/- 2.1 for caffeine, and 106.2 +/- 1.7 for (-)-epicatechin.

  20. An administrative data validation study of the accuracy of algorithms for identifying rheumatoid arthritis: the influence of the reference standard on algorithm performance.

    Science.gov (United States)

    Widdifield, Jessica; Bombardier, Claire; Bernatsky, Sasha; Paterson, J Michael; Green, Diane; Young, Jacqueline; Ivers, Noah; Butt, Debra A; Jaakkimainen, R Liisa; Thorne, J Carter; Tu, Karen

    2014-06-23

    We have previously validated administrative data algorithms to identify patients with rheumatoid arthritis (RA) using rheumatology clinic records as the reference standard. Here we reassessed the accuracy of the algorithms using primary care records as the reference standard. We performed a retrospective chart abstraction study using a random sample of 7500 adult patients under the care of 83 family physicians contributing to the Electronic Medical Record Administrative data Linked Database (EMRALD) in Ontario, Canada. Using physician-reported diagnoses as the reference standard, we computed and compared the sensitivity, specificity, and predictive values for over 100 administrative data algorithms for RA case ascertainment. We identified 69 patients with RA for a lifetime RA prevalence of 0.9%. All algorithms had excellent specificity (>97%). However, sensitivity varied (75-90%) among physician billing algorithms. Despite the low prevalence of RA, most algorithms had adequate positive predictive value (PPV; 51-83%). The algorithm of "[1 hospitalization RA diagnosis code] or [3 physician RA diagnosis codes with ≥1 by a specialist over 2 years]" had a sensitivity of 78% (95% CI 69-88), specificity of 100% (95% CI 100-100), PPV of 78% (95% CI 69-88) and NPV of 100% (95% CI 100-100). Administrative data algorithms for detecting RA patients achieved a high degree of accuracy amongst the general population. However, results varied slightly from our previous report, which can be attributed to differences in the reference standards with respect to disease prevalence, spectrum of disease, and type of comparator group.

  1. Reference results for time-like evolution up to O(α_s"3)

    International Nuclear Information System (INIS)

    Bertone, Valerio; Carrazza, Stefano; Nocera, Emanuele R.

    2015-01-01

    We present high-precision numerical results for time-like Dokshitzer-Gribov-Lipatov-Altarelli-Parisi evolution in the (MS)-bar factorisation scheme, for the first time up to next-to-next-to-leading order accuracy in quantum chromodynamics. First, we scrutinise the analytical expressions of the splitting functions available in the literature, in both x and N space, and check their mutual consistency. Second, we implement time-like evolution in two publicly available, entirely independent and conceptually different numerical codes, in x and N space respectively: the already existing APFEL code, which has been updated with time-like evolution, and the new MELA code, which has been specifically developed to perform the study in this work. Third, by means of a model for fragmentation functions, we provide results for the evolution in different factorisation schemes, for different ratios between renormalisation and factorisation scales and at different final scales. Our results are collected in the format of benchmark tables, which could be used as a reference for global determinations of fragmentation functions in the future.

  2. Validation of a motor activity system by a robotically controlled vehicle and using standard reference compounds.

    Science.gov (United States)

    Patterson, John P; Markgraf, Carrie G; Cirino, Maria; Bass, Alan S

    2005-01-01

    A series of experiments were undertaken to evaluate the accuracy, precision, specificity, and sensitivity of an automated, infrared photo beam-based open field motor activity system, the MotorMonitor v. 4.01, Hamilton-Kinder, LLC, for use in a good laboratory practices (GLP) Safety Pharmacology laboratory. This evaluation consisted of two phases: (1) system validation, employing known inputs using the EM-100 Controller Photo Beam Validation System, a robotically controlled vehicle representing a rodent and (2) biologic validation, employing groups of rats treated with the standard pharmacologic agents diazepam or D-amphetamine. The MotorMonitor's parameters that described the open-field activity of a subject were: basic movements, total distance, fine movements, x/y horizontal ambulations, rearing, and total rest time. These measurements were evaluated over a number of zones within each enclosure. System validation with the EM-100 Controller Photo Beam Validation System showed that all the parameters accurately and precisely measured what they were intended to measure, with the exception of fine movements and x/y ambulations. Biologic validation using the central nervous system depressant diazepam at 1, 2, or 5 mg/kg, i.p. produced the expected dose-dependent reduction in rat motor activity. In contrast, the central nervous system stimulant D-amphetamine produced the expected increases in rat motor activity at 0.1 and 1 mg/kg, i.p, demonstrating the specificity and sensitivity of the system. Taken together, these studies of the accuracy, precision, specificity, and sensitivity show the importance of both system and biologic validation in the evaluation of an automated open field motor activity system for use in a GLP compliant laboratory.

  3. Certification of a reference material for determination of total cyanide in soil to support implementation of the International Standard ISO 11262:2011.

    Science.gov (United States)

    Scharf, Holger; Bremser, Wolfram

    2015-04-01

    Cyanides are among the most important inorganic pollutants to be tested and monitored in environmental compartments. They can be distinguished and determined as free cyanide, weak acid dissociable cyanide or as total cyanide. However, in any case obtained, measurement results are operationally defined referring to the applied analytical method. In 2011, the International Standard ISO 11262 has been published which specifies a normative analytical method for the determination of total cyanide in soil. The objective of the project described in this paper was to provide the first soil reference material (CRM) certified for its mass fraction of total cyanide on the basis of this standard. A total of 12 German laboratories with proven experience in the determination of cyanides in environmental samples participated in the certification study. Measurement results were evaluated in full compliance with the requirements of ISO Guide 35. Taking into account the results of the inter-laboratory comparison as well as the outcome of the homogeneity and stability studies, a certified mass fraction of total cyanide of 21.1 mg/kg and an expanded uncertainty (k = 2) of 1.3 mg/kg were assigned to the material. The reference material has been issued as CRM BAM-U114.

  4. Technical Note: Modification of the standard gain correction algorithm to compensate for the number of used reference flat frames in detector performance studies

    International Nuclear Information System (INIS)

    Konstantinidis, Anastasios C.; Olivo, Alessandro; Speller, Robert D.

    2011-01-01

    Purpose: The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (FPN) to avoid contamination from nonstochastic processes. The ''gold standard'' method used for the reduction of the FPN (i.e., the different gain between pixels) in linear x-ray detectors is based on normalization with an average reference flat-field. However, the noise in the corrected image depends on the number of flat frames used for the average flat image. The aim of this study is to modify the standard gain correction algorithm to make it independent on the used reference flat frames. Methods: Many publications suggest the use of 10-16 reference flat frames, while other studies use higher numbers (e.g., 48 frames) to reduce the propagated noise from the average flat image. This study quantifies experimentally the effect of the number of used reference flat frames on the NPS and DQE values and appropriately modifies the gain correction algorithm to compensate for this effect. Results: It is shown that using the suggested gain correction algorithm a minimum number of reference flat frames (i.e., down to one frame) can be used to eliminate the FPN from the raw flat image. This saves computer memory and time during the x-ray performance evaluation. Conclusions: The authors show that the method presented in the study (a) leads to the maximum DQE value that one would have by using the conventional method and very large number of frames and (b) has been compared to an independent gain correction method based on the subtraction of flat-field images, leading to identical DQE values. They believe this provides robust validation of the proposed method.

  5. Assessment of stability of trace elements in two natural matrix environmental standard reference materials. NIST-SRM 1547 Peach leaves and NIST-SRM 1566a Oyster Tissue

    International Nuclear Information System (INIS)

    Mackey, E.A.; Spatz, R.O.

    2009-01-01

    The NIST program for environmental Standard Reference Materials (SRM) includes materials covering a range of matrices, mass fraction values and analytes. For many SRMs, mass fraction data are accumulated, incidentally, over time, as these are used routinely for quality assurance purposes. Although these are not formal stability studies, data generated may be useful in assessing stability. To evaluate the potential for assessing material stability from incidental use of SRMs, results of neutron activation analysis performed from 1992 through 2008 were compiled for SRM 1547 Peach Leaves and SRM 1566a Oyster Tissue. Results indicate that incidental use of SRMs yields useful information on SRM stability. (author)

  6. Establishing Upper Limits for Item Ratings for the Angoff Method: Are Resulting Standards More 'Realistic'?

    Science.gov (United States)

    Reid, Jerry B.

    This report investigates an area of uncertainty in using the Angoff method for setting standards, namely whether or not a judge's conceptualizations of borderline group performance are realistic. Ratings are usually made with reference to the performance of this hypothetical group, therefore the Angoff method's success is dependent on this point.…

  7. BIPM direct on-site Josephson voltage standard comparisons: 20 years of results

    International Nuclear Information System (INIS)

    Solve, Stephane; Stock, Michael

    2012-01-01

    The discovery of the Josephson effect has for the first time given national metrology institutes (NMIs) the possibility of maintaining voltage references which are stable in time. In addition, the introduction in 1990 of a conventional value for the Josephson constant, K J-90 , has greatly improved world-wide consistency among representations of the volt. For 20 years, the Bureau International des Poids et Mesures (BIPM) has conducted an ongoing, direct, on-site key comparison of Josephson voltage standards among NMIs under the denominations BIPM.EM-K10.a (1 V) and BIPM.EM-K10.b (10 V) in the framework of the mutual recognition arrangement (CIPM MRA). The results of 41 comparisons illustrate the consistency among primary voltage standards and have demonstrated that a relative total uncertainty of a few parts in 10 10 is achievable if a few precautions are taken with regard to the measurement set-up. Of particular importance are the grounding, efficient filters and high insulation resistance of the measurement leads, and clean microwave distribution along the propagation line to the Josephson array. This paper reviews the comparison scheme and technical issues that need to be taken into account to achieve a relative uncertainty at the level of a few parts in 10 10 or even a few parts in 10 11 in the best cases. (paper)

  8. Standard Practice for Analysis and Interpretation of Light-Water Reactor Surveillance Results, E706(IA)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This practice covers the methodology, summarized in Annex A1, to be used in the analysis and interpretation of neutron exposure data obtained from LWR pressure vessel surveillance programs; and, based on the results of that analysis, establishes a formalism to be used to evaluate present and future condition of the pressure vessel and its support structures (1-70). 1.2 This practice relies on, and ties together, the application of several supporting ASTM standard practices, guides, and methods (see Master Matrix E 706) (1, 5, 13, 48, 49). In order to make this practice at least partially self-contained, a moderate amount of discussion is provided in areas relating to ASTM and other documents. Support subject areas that are discussed include reactor physics calculations, dosimeter selection and analysis, and exposure units. Note 1—(Figure 1 is deleted in the latest update. The user is refered to Master Matrix E 706 for the latest figure of the standards interconnectivity). 1.3 This practice is restri...

  9. Biomass-burning derived aromatic acids in NIST standard reference material 1649b and the environmental implications

    Science.gov (United States)

    Gao, Shaopeng; Xu, Baiqing; Dong, Xueling; Zheng, Xiaoyan; Wan, Xin; Kang, Shichang; Song, Qiuyin; Kawamura, Kimitaka; Cong, Zhiyuan

    2018-07-01

    Biomass burning is a serious problem in the environment and climate system. However, the source identification of biomass-burning aerosols was somewhat impeded, partly due to the difficulty in quantification of relevant molecular markers. In this study, we present reference values for five aromatic acids (including p-hydroxybenzoic, vanillic, dehydroabietic, syringic and p-coumaric acids) in the NIST Standard Reference Material (SRM) 1649b. The concentration of levoglucosan was also revisited. Notable positive matrix effect was found for vanillic, dehydroabietic, syringic and coumaric acid. Using the standard addition method, the average value of p-hydroxybenzoic, vanillic, syringic, dehydroabietic and p-coumaric acids in SRM 1649b were found to be 26.9, 9.53, 1.13, 7.60 and 1.66 μg g-1, respectively. The analytical method developed in this study was also applied to the PM10 samples from Beijing and PM2.5 samples from South Asia (Godavari, Nepal). The ratios of vanillic to p-hydroxybenzoic acid and syringic to vanillic acid further suggested that their biomass-burning types are mainly related to hard wood and herbaceous species (i.e., agricultural residues).

  10. Consequences of new reference climate years according to the Dutch standard NEN 5060; Gevolgen nieuwe referentieklimaatjaren volgens NEN 5060

    Energy Technology Data Exchange (ETDEWEB)

    Hooft, E.N. ' t [Grontmij, Amersfoort (Netherlands)

    2009-02-15

    Because of the climate changes the reference year 1964-1965 is a topic of discussion as on appropriate climate file for the design of climate installations. Therefor, in the Netherlands, new climate reference years are developed for temperature and energy calculations, outlined in the Dutch standard NEN 5060 (Hygrothermal properties of buildings. Reference climate data). This article shows for a nursing home the consequences on the design, energy consumption and energy costs of the climate installation. [Dutch] Vanwege de klimaatveranderingen, die een duidelijke trend naar warmere jaren laat zien, staat het referentiejaar 1964-1965 ter discussie als geschikt klimaatbestand voor bet ontwerp van klimaatinstallaties. Om die reden zijn voor Nederland nieuwe referentieklimaatjaren ontwikkeld voor temperatuur- en energieberekeningen, die zijn opgenomen in NEN 5060 (Hygro-thermische eigenschappen van gebouwen. Referentieklimaatgegevens), die als definitieve versie is verschenen. Dit artikel laat aan de hand van een rekenstudie aan een referentiegebouw in de gezondheidszorg (verpleeghuis) zien wat de consequenties zijn van de nieuw ontwikkelde referentieklimaatjaren op bet ontwerp, het energiegebruik en de energiekosten van de klimaatinstallatie.

  11. Physical fitness reference standards in fibromyalgia: The al-Ándalus project.

    Science.gov (United States)

    Álvarez-Gallardo, I C; Carbonell-Baeza, A; Segura-Jiménez, V; Soriano-Maldonado, A; Intemann, T; Aparicio, V A; Estévez-López, F; Camiletti-Moirón, D; Herrador-Colmenero, M; Ruiz, J R; Delgado-Fernández, M; Ortega, F B

    2017-11-01

    We aimed (1) to report age-specific physical fitness levels in people with fibromyalgia of a representative sample from Andalusia; and (2) to compare the fitness levels of people with fibromyalgia with non-fibromyalgia controls. This cross-sectional study included 468 (21 men) patients with fibromyalgia and 360 (55 men) controls. The fibromyalgia sample was geographically representative from southern Spain. Physical fitness was assessed with the Senior Fitness Test battery plus the handgrip test. We applied the Generalized Additive Model for Location, Scale and Shape to calculate percentile curves for women and fitted mean curves using a linear regression for men. Our results show that people with fibromyalgia reached worse performance in all fitness tests than controls (P fitness levels among patients with fibromyalgia and controls in a large sample of patients with fibromyalgia from southern of Spain. Physical fitness levels of people with fibromyalgia from Andalusia are very low in comparison with age-matched healthy controls. This information could be useful to correctly interpret physical fitness assessments and helping health care providers to identify individuals at risk for losing physical independence. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. The Lyman alpha reference sample. II. Hubble space telescope imaging results, integrated properties, and trends

    Energy Technology Data Exchange (ETDEWEB)

    Hayes, Matthew; Östlin, Göran; Duval, Florent; Sandberg, Andreas; Guaita, Lucia; Melinder, Jens; Rivera-Thorsen, Thøger [Department of Astronomy, Oskar Klein Centre, Stockholm University, AlbaNova University Centre, SE-106 91 Stockholm (Sweden); Adamo, Angela [Max Planck Institute for Astronomy, Königstuhl 17, D-69117 Heidelberg (Germany); Schaerer, Daniel [Université de Toulouse, UPS-OMP, IRAP, F-31000 Toulouse (France); Verhamme, Anne; Orlitová, Ivana [Geneva Observatory, University of Geneva, 51 Chemin des Maillettes, CH-1290 Versoix (Switzerland); Mas-Hesse, J. Miguel; Otí-Floranes, Héctor [Centro de Astrobiología (CSIC-INTA), Departamento de Astrofísica, P.O. Box 78, E-28691 Villanueva de la Cañada (Spain); Cannon, John M.; Pardy, Stephen [Department of Physics and Astronomy, Macalester College, 1600 Grand Avenue, Saint Paul, MN 55105 (United States); Atek, Hakim [Laboratoire dAstrophysique, École Polytechnique Fédérale de Lausanne (EPFL), Observatoire, CH-1290 Sauverny (Switzerland); Kunth, Daniel [Institut d' Astrophysique de Paris, UMR 7095, CNRS and UPMC, 98 bis Bd Arago, F-75014 Paris (France); Laursen, Peter [Dark Cosmology Centre, Niels Bohr Institute, University of Copenhagen, Juliane Maries Vej 30, DK-2100 Copenhagen (Denmark); Herenz, E. Christian, E-mail: matthew@astro.su.se [Leibniz-Institut für Astrophysik (AIP), An der Sternwarte 16, D-14482 Potsdam (Germany)

    2014-02-10

    We report new results regarding the Lyα output of galaxies, derived from the Lyman Alpha Reference Sample, and focused on Hubble Space Telescope imaging. For 14 galaxies we present intensity images in Lyα, Hα, and UV, and maps of Hα/Hβ, Lyα equivalent width (EW), and Lyα/Hα. We present Lyα and UV radial light profiles and show they are well-fitted by Sérsic profiles, but Lyα profiles show indices systematically lower than those of the UV (n ≈ 1-2 instead of ≳ 4). This reveals a general lack of the central concentration in Lyα that is ubiquitous in the UV. Photometric growth curves increase more slowly for Lyα than the far ultraviolet, showing that small apertures may underestimate the EW. For most galaxies, however, flux and EW curves flatten by radii ≈10 kpc, suggesting that if placed at high-z only a few of our galaxies would suffer from large flux losses. We compute global properties of the sample in large apertures, and show total Lyα luminosities to be independent of all other quantities. Normalized Lyα throughput, however, shows significant correlations: escape is found to be higher in galaxies of lower star formation rate, dust content, mass, and nebular quantities that suggest harder ionizing continuum and lower metallicity. Six galaxies would be selected as high-z Lyα emitters, based upon their luminosity and EW. We discuss the results in the context of high-z Lyα and UV samples. A few galaxies have EWs above 50 Å, and one shows f{sub esc}{sup Lyα} of 80%; such objects have not previously been reported at low-z.

  13. The Lyman alpha reference sample. II. Hubble space telescope imaging results, integrated properties, and trends

    International Nuclear Information System (INIS)

    Hayes, Matthew; Östlin, Göran; Duval, Florent; Sandberg, Andreas; Guaita, Lucia; Melinder, Jens; Rivera-Thorsen, Thøger; Adamo, Angela; Schaerer, Daniel; Verhamme, Anne; Orlitová, Ivana; Mas-Hesse, J. Miguel; Otí-Floranes, Héctor; Cannon, John M.; Pardy, Stephen; Atek, Hakim; Kunth, Daniel; Laursen, Peter; Herenz, E. Christian

    2014-01-01

    We report new results regarding the Lyα output of galaxies, derived from the Lyman Alpha Reference Sample, and focused on Hubble Space Telescope imaging. For 14 galaxies we present intensity images in Lyα, Hα, and UV, and maps of Hα/Hβ, Lyα equivalent width (EW), and Lyα/Hα. We present Lyα and UV radial light profiles and show they are well-fitted by Sérsic profiles, but Lyα profiles show indices systematically lower than those of the UV (n ≈ 1-2 instead of ≳ 4). This reveals a general lack of the central concentration in Lyα that is ubiquitous in the UV. Photometric growth curves increase more slowly for Lyα than the far ultraviolet, showing that small apertures may underestimate the EW. For most galaxies, however, flux and EW curves flatten by radii ≈10 kpc, suggesting that if placed at high-z only a few of our galaxies would suffer from large flux losses. We compute global properties of the sample in large apertures, and show total Lyα luminosities to be independent of all other quantities. Normalized Lyα throughput, however, shows significant correlations: escape is found to be higher in galaxies of lower star formation rate, dust content, mass, and nebular quantities that suggest harder ionizing continuum and lower metallicity. Six galaxies would be selected as high-z Lyα emitters, based upon their luminosity and EW. We discuss the results in the context of high-z Lyα and UV samples. A few galaxies have EWs above 50 Å, and one shows f esc Lyα of 80%; such objects have not previously been reported at low-z.

  14. Establishing the Antarctic Dome C community reference standard site towards consistent measurements from Earth observation satellites

    Science.gov (United States)

    Cao, C.; Uprety, S.; Xiong, J.; Wu, A.; Jing, P.; Smith, D.; Chander, G.; Fox, N.; Ungar, S.

    2010-01-01

    Establishing satellite measurement consistency by using common desert sites has become increasingly more important not only for climate change detection but also for quantitative retrievals of geophysical variables in satellite applications. Using the Antarctic Dome C site (75°06′S, 123°21′E, elevation 3.2 km) for satellite radiometric calibration and validation (Cal/Val) is of great interest owing to its unique location and characteristics. The site surface is covered with uniformly distributed permanent snow, and the atmospheric effect is small and relatively constant. In this study, the long-term stability and spectral characteristics of this site are evaluated using well-calibrated satellite instruments such as the Moderate Resolution Imaging Spectroradiometer (MODIS) and Sea-viewing Wide Field-of-view Sensor (SeaWiFS). Preliminary results show that despite a few limitations, the site in general is stable in the long term, the bidirectional reflectance distribution function (BRDF) model works well, and the site is most suitable for the Cal/Val of reflective solar bands in the 0.4–1.0 µm range. It was found that for the past decade, the reflectivity change of the site is within 1.35% at 0.64 µm, and interannual variability is within 2%. The site is able to resolve calibration biases between instruments at a level of ~1%. The usefulness of the site is demonstrated by comparing observations from seven satellite instruments involving four space agencies, including OrbView-2–SeaWiFS, Terra–Aqua MODIS, Earth Observing 1 (EO-1) – Hyperion, Meteorological Operational satellite programme (MetOp) – Advanced Very High Resolution Radiometer (AVHRR), Envisat Medium Resolution Imaging Spectrometer (MERIS) – dvanced Along-Track Scanning Radiometer (AATSR), and Landsat 7 Enhanced Thematic Mapper Plus (ETM+). Dome C is a promising candidate site for climate quality calibration of satellite radiometers towards more consistent satellite measurements, as part

  15. Main results of the standardization through anti-coincident from the Brazilian Laboratory for Metrology of Ionizing Radiations - LNMRI/IRD/CNEN-RJ in the last 8 years

    International Nuclear Information System (INIS)

    Silva, Carlos J. da

    2014-01-01

    The LNMRI implemented in 2006 a system of time keeping in anticoincidence live in this time and dead time extensible today 18 radionuclides were standardized. To store the results of these primary standardization the LNMRI/IRD reference with ionization chamber were calibrated with these standards. In this work will be discussed the main operational difficulties and components of uncertainty and the main results. (author)

  16. Determination of caffeine, theobromine, and theophylline in standard reference material 2384, baking chocolate, using reversed-phase liquid chromatography.

    Science.gov (United States)

    Thomas, Jeanice Brown; Yen, James H; Schantz, Michele M; Porter, Barbara J; Sharpless, Katherine E

    2004-06-02

    A rapid and selective isocratic reversed-phase liquid chromatographic method has been developed at the National Institute of Standards and Technology to simultaneously measure caffeine, theobromine, and theophylline in a food-matrix standard reference material (SRM) 2384, Baking Chocolate. The method uses isocratic elution with a mobile phase composition (volume fractions) of 10% acetronitrile/90% water (pH adjusted to 2.5 using acetic acid) at a flow rate of 1.5 mL/min with ultraviolet absorbance detection (274 nm). Total elution time for these analytes is less than 15 min. Concentration levels of caffeine, theobromine, and theophylline were measured in single 1-g samples taken from each of eight bars of chocolate over an eight-day period. Samples were defatted with hexane, and beta-hydroxyethyltheophylline was added as the internal standard. The repeatability for the caffeine, theobromine, and theophylline measurements was 5.1, 2.3, and 1.9%, respectively. The limit of quantitation for all analytes was theobromine, and theophylline in SRM 2384.

  17. NEURO-SYSTEM OF AIMING AND STABILIZING WITH A REGULATOR ON THE BASIS OF STANDARD MODEL MODEL REFERENCE CONTROLLER

    Directory of Open Access Journals (Sweden)

    B.I. Kuznetsov

    2015-08-01

    Full Text Available The aim of this work is the synthesis of neural network aiming and stabilization system for the special equipment of moving objects with neuro-controller on the basis of standard model and performance comparison of the neural network system with the neural network predictive control. Build a block diagram of the neural network aiming and stabilization system, based on the subject control principle with PD-regulator in the position loop and with neuro-controller on the basis of standard model in the in the velocity loop. The neuro-controller on the basis of standard model Model Reference Controller is synthesized in the MATLAB Neural Network Toolbox and system simulation is performed. The studies show that the transient state variables of the system are oscillatory. Therefore, the neuro-controller with the prediction NN Predictive Controller should be used for aiming and stabilizing system to provide high dynamic characteristics achieved at the cost of higher complexity and computational cost.

  18. Practical utilization of recombinant AAV vector reference standards: focus on vector genomes titration by free ITR qPCR

    Directory of Open Access Journals (Sweden)

    Susan D'Costa

    2016-01-01

    Full Text Available Clinical trials using recombinant adeno-associated virus (rAAV vectors have demonstrated efficacy and a good safety profile. Although the field is advancing quickly, vector analytics and harmonization of dosage units are still a limitation for commercialization. AAV reference standard materials (RSMs can help ensure product safety by controlling the consistency of assays used to characterize rAAV stocks. The most widely utilized unit of vector dosing is based on the encapsidated vector genome. Quantitative polymerase chain reaction (qPCR is now the most common method to titer vector genomes (vg; however, significant inter- and intralaboratory variations have been documented using this technique. Here, RSMs and rAAV stocks were titered on the basis of an inverted terminal repeats (ITRs sequence-specific qPCR and we found an artificial increase in vg titers using a widely utilized approach. The PCR error was introduced by using single-cut linearized plasmid as the standard curve. This bias was eliminated using plasmid standards linearized just outside the ITR region on each end to facilitate the melting of the palindromic ITR sequences during PCR. This new “Free-ITR” qPCR delivers vg titers that are consistent with titers obtained with transgene-specific qPCR and could be used to normalize in-house product-specific AAV vector standards and controls to the rAAV RSMs. The free-ITR method, including well-characterized controls, will help to calibrate doses to compare preclinical and clinical data in the field.

  19. Practical utilization of recombinant AAV vector reference standards: focus on vector genomes titration by free ITR qPCR.

    Science.gov (United States)

    D'Costa, Susan; Blouin, Veronique; Broucque, Frederic; Penaud-Budloo, Magalie; François, Achille; Perez, Irene C; Le Bec, Christine; Moullier, Philippe; Snyder, Richard O; Ayuso, Eduard

    2016-01-01

    Clinical trials using recombinant adeno-associated virus (rAAV) vectors have demonstrated efficacy and a good safety profile. Although the field is advancing quickly, vector analytics and harmonization of dosage units are still a limitation for commercialization. AAV reference standard materials (RSMs) can help ensure product safety by controlling the consistency of assays used to characterize rAAV stocks. The most widely utilized unit of vector dosing is based on the encapsidated vector genome. Quantitative polymerase chain reaction (qPCR) is now the most common method to titer vector genomes (vg); however, significant inter- and intralaboratory variations have been documented using this technique. Here, RSMs and rAAV stocks were titered on the basis of an inverted terminal repeats (ITRs) sequence-specific qPCR and we found an artificial increase in vg titers using a widely utilized approach. The PCR error was introduced by using single-cut linearized plasmid as the standard curve. This bias was eliminated using plasmid standards linearized just outside the ITR region on each end to facilitate the melting of the palindromic ITR sequences during PCR. This new "Free-ITR" qPCR delivers vg titers that are consistent with titers obtained with transgene-specific qPCR and could be used to normalize in-house product-specific AAV vector standards and controls to the rAAV RSMs. The free-ITR method, including well-characterized controls, will help to calibrate doses to compare preclinical and clinical data in the field.

  20. An open source, 3D printed preclinical MRI phantom for repeated measures of contrast agents and reference standards.

    Science.gov (United States)

    Cox, B L; Ludwig, K D; Adamson, E B; Eliceiri, K W; Fain, S B

    2018-03-01

    In medical imaging, clinicians, researchers and technicians have begun to use 3D printing to create specialized phantoms to replace commercial ones due to their customizable and iterative nature. Presented here is the design of a 3D printed open source, reusable magnetic resonance imaging (MRI) phantom, capable of flood-filling, with removable samples for measurements of contrast agent solutions and reference standards, and for use in evaluating acquisition techniques and image reconstruction performance. The phantom was designed using SolidWorks, a computer-aided design software package. The phantom consists of custom and off-the-shelf parts and incorporates an air hole and Luer Lock system to aid in flood filling, a marker for orientation of samples in the filled mode and bolt and tube holes for assembly. The cost of construction for all materials is under $90. All design files are open-source and available for download. To demonstrate utility, B 0 field mapping was performed using a series of gadolinium concentrations in both the unfilled and flood-filled mode. An excellent linear agreement (R 2 >0.998) was observed between measured relaxation rates (R 1 /R 2 ) and gadolinium concentration. The phantom provides a reliable setup to test data acquisition and reconstruction methods and verify physical alignment in alternative nuclei MRI techniques (e.g. carbon-13 and fluorine-19 MRI). A cost-effective, open-source MRI phantom design for repeated quantitative measurement of contrast agents and reference standards in preclinical research is presented. Specifically, the work is an example of how the emerging technology of 3D printing improves flexibility and access for custom phantom design.

  1. Comparative assay of fluorescent antibody test results among twelve European National Reference Laboratories using various anti-rabies conjugates

    DEFF Research Database (Denmark)

    Robardet, E.; Andrieu, S.; Rasmussen, Thomas Bruun

    2013-01-01

    Twelve National Reference Laboratories (NRLs) for rabies have undertaken a comparative assay to assess the comparison of fluorescent antibody test (FAT) results using five coded commercial anti-rabies conjugates (Biorad, Bioveta, Fujirebio, Millipore, and SIFIN conjugates). Homogenized positive...

  2. Evaluation of new geological reference materials for uranium-series measurements: Chinese Geological Standard Glasses (CGSG) and macusanite obsidian.

    Science.gov (United States)

    Denton, J S; Murrell, M T; Goldstein, S J; Nunn, A J; Amato, R S; Hinrichs, K A

    2013-10-15

    Recent advances in high-resolution, rapid, in situ microanalytical techniques present numerous opportunities for the analytical community, provided accurately characterized reference materials are available. Here, we present multicollector thermal ionization mass spectrometry (MC-TIMS) and multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) uranium and thorium concentration and isotopic data obtained by isotope dilution for a suite of newly available Chinese Geological Standard Glasses (CGSG) designed for microanalysis. These glasses exhibit a range of compositions including basalt, syenite, andesite, and a soil. Uranium concentrations for these glasses range from ∼2 to 14 μg g(-1), Th/U weight ratios range from ∼4 to 6, (234)U/(238)U activity ratios range from 0.93 to 1.02, and (230)Th/(238)U activity ratios range from 0.98 to 1.12. Uranium and thorium concentration and isotopic data are also presented for a rhyolitic obsidian from Macusani, SE Peru (macusanite). This glass can also be used as a rhyolitic reference material, has a very low Th/U weight ratio (around 0.077), and is approximately in (238)U-(234)U-(230)Th secular equilibrium. The U-Th concentration data agree with but are significantly more precise than those previously measured. U-Th concentration and isotopic data agree within estimated errors for the two measurement techniques, providing validation of the two methods. The large (238)U-(234)U-(230)Th disequilibria for some of the glasses, along with the wide range in their chemical compositions and Th/U ratios should provide useful reference points for the U-series analytical community.

  3. Development of the neutron reference calibration field using a {sup 252}Cf standard source surrounded with PMMA moderators

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, T.; Kanai, K.; Tsujimura, N. [Japan Nuclear Cycle Development Institute, Ibaraki-ken (Japan)

    2002-07-01

    The authors developed the neutron reference calibration fields using a {sup 252} Cf standard source surrounded with PMMA moderators at the Japan Nuclear Cycle Development (JNC), Tokai Works. The moderators are co-axial, hollow cylinders made of lead-contained PMMA with a thickness of 13.5, 35.0, 59.5 and 77.0mm, and the {sup 252} Cf source is guided to the geometric center of moderators by the pneumatic system. These fields can provide the moderated neutron spectra very similar to those encountered around the globe-boxes of the fabrication process of MOX (PuO{sub 2}-UO{sub 2} mixed oxide) fuel. The neutron energy spectrum at the reference calibration point was evaluated from the calculations by MCNP4B and the measurements by the INS-type Bonner multi-sphere spectrometer and the hydrogen-filled proportional counters. The calculated neutron spectra were in good agreements with the measured ones. These fields were characterized in terms of the neutron fluence rate, spectral composition and ambient dose equivalent rate, and have served for the response-characterization of various neutron survey instruments.

  4. Development of the neutron reference calibration field using a 252Cf standard source surrounded with PMMA moderators

    International Nuclear Information System (INIS)

    Yoshida, T.; Kanai, K.; Tsujimura, N.

    2002-01-01

    The authors developed the neutron reference calibration fields using a 252 Cf standard source surrounded with PMMA moderators at the Japan Nuclear Cycle Development (JNC), Tokai Works. The moderators are co-axial, hollow cylinders made of lead-contained PMMA with a thickness of 13.5, 35.0, 59.5 and 77.0mm, and the 252 Cf source is guided to the geometric center of moderators by the pneumatic system. These fields can provide the moderated neutron spectra very similar to those encountered around the globe-boxes of the fabrication process of MOX (PuO 2 -UO 2 mixed oxide) fuel. The neutron energy spectrum at the reference calibration point was evaluated from the calculations by MCNP4B and the measurements by the INS-type Bonner multi-sphere spectrometer and the hydrogen-filled proportional counters. The calculated neutron spectra were in good agreements with the measured ones. These fields were characterized in terms of the neutron fluence rate, spectral composition and ambient dose equivalent rate, and have served for the response-characterization of various neutron survey instruments

  5. Solid phase speciation of arsenic by sequential extraction in standard reference materials and industrially contaminated soil samples

    International Nuclear Information System (INIS)

    Herreweghe, Samuel van; Swennen, Rudy; Vandecasteele, Carlo; Cappuyns, Valerie

    2003-01-01

    Leaching experiments, a mineralogical survey and larger samples are preferred when arsenic is present as discrete mineral phases. - Availability, mobility, (phyto)toxicity and potential risk of contaminants is strongly affected by the manner of appearance of elements, the so-called speciation. Operational fractionation methods like sequential extractions have been applied for a long time to determine the solid phase speciation of heavy metals since direct determination of specific chemical compounds can not always be easily achieved. The three-step sequential extraction scheme recommended by the BCR and two extraction schemes based on the phosphorus-like protocol proposed by Manful (1992, Occurrence and Ecochemical Behaviours of Arsenic in a Goldsmelter Impacted Area in Ghana, PhD dissertation, at the RUG) were applied to four standard reference materials (SRM) and to a batch of samples from industrially contaminated sites, heavily contaminated with arsenic and heavy metals. The SRM 2710 (Montana soil) was found to be the most useful reference material for metal (Mn, Cu, Zn, As, Cd and Pb) fractionation using the BCR sequential extraction procedure. Two sequential extraction schemes were developed and compared for arsenic with the aim to establish a better fractionation and recovery rate than the BCR-scheme for this element in the SRM samples. The major part of arsenic was released from the heavily contaminated samples after NaOH-extraction. Inferior extraction variability and recovery in the heavily contaminated samples compared to SRMs could be mainly contributed to subsample heterogeneity

  6. Reference News Release: U.S. Files Complaint, Announces Settlement to Address Alleged Renewable Fuel Standard Violations by NGL Crude Logistics and Western Dubuque Biodiesel

    Science.gov (United States)

    Reference news release on the complaint against NGL Crude Logistics, LLC and Western Dubuque Biodiesel, LLC and a settlement with Western Dubuque to address alleged violations of the Renewable Fuel Standard.

  7. Global panel of HIV-1 Env reference strains for standardized assessments of vaccine-elicited neutralizing antibodies.

    Science.gov (United States)

    deCamp, Allan; Hraber, Peter; Bailer, Robert T; Seaman, Michael S; Ochsenbauer, Christina; Kappes, John; Gottardo, Raphael; Edlefsen, Paul; Self, Steve; Tang, Haili; Greene, Kelli; Gao, Hongmei; Daniell, Xiaoju; Sarzotti-Kelsoe, Marcella; Gorny, Miroslaw K; Zolla-Pazner, Susan; LaBranche, Celia C; Mascola, John R; Korber, Bette T; Montefiori, David C

    2014-03-01

    Standardized assessments of HIV-1 vaccine-elicited neutralizing antibody responses are complicated by the genetic and antigenic variability of the viral envelope glycoproteins (Envs). To address these issues, suitable reference strains are needed that are representative of the global epidemic. Several panels have been recommended previously, but no clear answers have been available on how many and which strains are best suited for this purpose. We used a statistical model selection method to identify a global panel of reference Env clones from among 219 Env-pseudotyped viruses assayed in TZM-bl cells with sera from 205 HIV-1-infected individuals. The Envs and sera were sampled globally from diverse geographic locations and represented all major genetic subtypes and circulating recombinant forms of the virus. Assays with a panel size of only nine viruses adequately represented the spectrum of HIV-1 serum neutralizing activity seen with the larger panel of 219 viruses. An optimal panel of nine viruses was selected and augmented with three additional viruses for greater genetic and antigenic coverage. The spectrum of HIV-1 serum neutralizing activity seen with the final 12-virus panel closely approximated the activity seen with subtype-matched viruses. Moreover, the final panel was highly sensitive for detection of many of the known broadly neutralizing antibodies. For broader assay applications, all 12 Env clones were converted to infectious molecular clones using a proviral backbone carrying a Renilla luciferase reporter gene (Env.IMC.LucR viruses). This global panel should facilitate highly standardized assessments of vaccine-elicited neutralizing antibodies across multiple HIV-1 vaccine platforms in different parts of the world. An effective HIV-1 vaccine will need to overcome the extraordinary genetic variability of the virus, where most variation occurs in the viral envelope glycoproteins that are the sole targets for neutralizing antibodies. Efforts to elicit

  8. Diagnostic reference levels for common computed tomography (CT) examinations: results from the first Nigerian nationwide dose survey.

    Science.gov (United States)

    Ekpo, Ernest U; Adejoh, Thomas; Akwo, Judith D; Emeka, Owujekwe C; Modu, Ali A; Abba, Mohammed; Adesina, Kudirat A; Omiyi, David O; Chiegwu, Uche H

    2018-01-29

    To explore doses from common adult computed tomography (CT) examinations and propose national diagnostic reference levels (nDRLs) for Nigeria. This retrospective study was approved by the Nnamdi Azikiwe University and University Teaching Hospital Institutional Review Boards (IRB: NAUTH/CS/66/Vol8/84) and involved dose surveys of adult CT examinations across the six geographical regions of Nigeria and Abuja from January 2016 to August 2017. Dose data of adult head, chest and abdomen/pelvis CT examinations were extracted from patient folders. The median, 75th and 25th percentile CT dose index volume (CTDI vol ) and dose-length-product (DLP) were computed for each of these procedures. Effective doses (E) for these examinations were estimated using the k conversion factor as described in the ICRP publication 103 (E DLP  =  k × DLP ). The proposed 75th percentile CTDI vol for head, chest, and abdomen/pelvis are 61 mGy, 17 mGy, and 20 mGy, respectively. The corresponding DLPs are 1310 mGy.cm, 735 mGy.cm, and 1486 mGy.cm respectively. The effective doses were 2.75 mSv (head), 10.29 mSv (chest), and 22.29 mSv (abdomen/pelvis). Findings demonstrate wide dose variations within and across centres in Nigeria. The results also show CTDI vol comparable to international standards, but considerably higher DLP and effective doses.

  9. Characterization of the Defense Waste Processing Facility (DWPF) Environmental Assessment (EA) glass Standard Reference Material. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Crawford, C.L.; Pickett, M.A.

    1993-06-01

    Liquid high-level nuclear waste at the Savannah River Site (SRS) will be immobilized by vitrification in borosilicate glass. The glass will be produced and poured into stainless steel canisters in the Defense Waste Processing Facility (DWPF). Other waste form producers, such as West Valley Nuclear Services (WVNS) and the Hanford Waste Vitrification Project (HWVP), will also immobilize high-level radioactive waste in borosilicate glass. The canistered waste will be stored temporarily at each facility for eventual permanent disposal in a geologic repository. The Department of Energy has defined a set of requirements for the canistered waste forms, the Waste Acceptance Product Specifications (WAPS). The current Waste Acceptance Primary Specification (WAPS) 1.3, the product consistency specification, requires the waste form producers to demonstrate control of the consistency of the final waste form using a crushed glass durability test, the Product Consistency Test (PCI). In order to be acceptable, a waste glass must be more durable during PCT analysis than the waste glass identified in the DWPF Environmental Assessment (EA). In order to supply all the waste form producers with the same standard benchmark glass, 1000 pounds of the EA glass was fabricated. The chemical analyses and characterization of the benchmark EA glass are reported. This material is now available to act as a durability and/or redox Standard Reference Material (SRM) for all waste form producers.

  10. Recent references

    International Nuclear Information System (INIS)

    Ramavataram, S.

    1991-01-01

    In support of a continuing program of systematic evaluation of nuclear structure data, the National Nuclear Data Center maintains a complete computer file of references to the nuclear physics literature. Each reference is tagged by a keyword string, which indicates the kinds of data contained in the article. This master file of Nuclear Structure References (NSR) contains complete keyword indexes to literature published since 1969, with partial indexing of older references. Any reader who finds errors in the keyword descriptions is urged to report them to the National Nuclear Data Center so that the master NSR file can be corrected. In 1966, the first collection of Recent References was published as a separate issue of Nuclear Data Sheets. Every four months since 1970, a similar indexed bibliography to new nuclear experiments has been prepared from additions to the NSR file and published. Beginning in 1978, Recent References was cumulated annually, with the third issue completely superseding the two issues previously published during a given year. Due to publication policy changes, cumulation of Recent Reference was discontinued in 1986. The volume and issue number of all the cumulative issues published to date are given. NNDC will continue to respond to individual requests for special bibliographies on nuclear physics topics, in addition to those easily obtained from Recent References. If the required information is available from the keyword string, a reference list can be prepared automatically from the computer files. This service can be provided on request, in exchange for the timely communication of new nuclear physics results (e.g., preprints). A current copy of the NSR file may also be obtained in a standard format on magnetic tape from NNDC. Requests for special searches of the NSR file may also be directed to the National Nuclear Data Center

  11. Echocardiographic reference ranges for normal left atrial function parameters: results from the EACVI NORRE study.

    Science.gov (United States)

    Sugimoto, Tadafumi; Robinet, Sébastien; Dulgheru, Raluca; Bernard, Anne; Ilardi, Federica; Contu, Laura; Addetia, Karima; Caballero, Luis; Kacharava, George; Athanassopoulos, George D; Barone, Daniele; Baroni, Monica; Cardim, Nuno; Hagendorff, Andreas; Hristova, Krasimira; Lopez, Teresa; de la Morena, Gonzalo; Popescu, Bogdan A; Penicka, Martin; Ozyigit, Tolga; Rodrigo Carbonero, Jose David; van de Veire, Nico; Von Bardeleben, Ralph Stephan; Vinereanu, Dragos; Zamorano, Jose Luis; Go, Yun Yun; Marchetta, Stella; Nchimi, Alain; Rosca, Monica; Calin, Andreea; Moonen, Marie; Cimino, Sara; Magne, Julien; Cosyns, Bernard; Galli, Elena; Donal, Erwan; Habib, Gilbert; Esposito, Roberta; Galderisi, Maurizio; Badano, Luigi P; Lang, Roberto M; Lancellotti, Patrizio

    2018-02-23

    To obtain the normal ranges for echocardiographic measurements of left atrial (LA) function from a large group of healthy volunteers accounting for age and gender. A total of 371 (median age 45 years) healthy subjects were enrolled at 22 collaborating institutions collaborating in the Normal Reference Ranges for Echocardiography (NORRE) study of the European Association of Cardiovascular Imaging (EACVI). Left atrial data sets were analysed with a vendor-independent software (VIS) package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire data sets. The lowest expected values of LA function were 26.1%, 48.7%, and 41.4% for left atrial strain (LAS), 2D left atrial emptying fraction (LAEF), and 3D LAEF (reservoir function); 7.7%, 24.2%, and -0.53/s for LAS-active, LAEF-active, and LA strain rate during LA contraction (SRa) (pump function) and 12.0% and 21.6% for LAS-passive and LAEF-passive (conduit function). Left atrial reservoir and conduit function were decreased with age while pump function was increased. All indices of reservoir function and all LA strains had no difference in both gender and vendor. However, inter-vendor differences were observed in LA SRa despite the use of VIS. The NORRE study provides contemporary, applicable echocardiographic reference ranges for LA function. Our data highlight the importance of age-specific reference values for LA functions.

  12. The Lyα reference sample. I. Survey outline and first results for Markarian 259

    International Nuclear Information System (INIS)

    Östlin, Göran; Hayes, Matthew; Duval, Florent; Sandberg, Andreas; Rivera-Thorsen, Thøger; Marquart, Thomas; Adamo, Angela; Melinder, Jens; Guaita, Lucia; Micheva, Genoveva; Orlitová, Ivana; Atek, Hakim; Cannon, John M.; Pardy, Stephen A.; Gruyters, Pieter; Herenz, Edmund Christian; Kunth, Daniel; Laursen, Peter; Mas-Hesse, J. Miguel; Otí-Floranes, Héctor

    2014-01-01

    The Lyα Reference Sample (LARS) is a substantial program with the Hubble Space Telescope (HST) that provides a sample of local universe laboratory galaxies in which to study the detailed astrophysics of the visibility and strength of the Lyαline of neutral hydrogen. Lyα is the dominant spectral line in use for characterizing high-redshift (z) galaxies. This paper presents an overview of the survey, its selection function, and HST imaging observations. The sample was selected from the combined GALEX+Sloan Digital Sky Survey catalog at z = 0.028-0.19, in order to allow Lyα to be captured with combinations of long-pass filters in the Solar Blind Channel (SBC) of the Advanced Camera for Surveys (ACS) onboard HST. In addition, LARS utilizes Hα and Hβ narrowband and u, b, i broadband imaging with ACS and the Wide Field Camera 3 (WFC3). In order to study galaxies in which large numbers of Lyα photons are produced (whether or not they escape), we demanded an Hα equivalent width W(Hα) ≥100 Å. The final sample of 14 galaxies covers far-UV (FUV, λ ∼ 1500 Å) luminosities that overlap with those of high-z Lyα emitters (LAEs) and Lyman break galaxies (LBGs), making LARS a valid comparison sample. We present the reduction steps used to obtain the Lyα images, including our LARS eXtraction software (LaXs), which utilizes pixel-by-pixel spectral synthesis fitting of the energy distribution to determine and subtract the continuum at Lyα. We demonstrate that the use of SBC long-pass-filter combinations increase the signal-to-noise ratio by an order of magnitude compared to the nominal Lyα filter available in SBC. To exemplify the science potential of LARS, we also present some first results for a single galaxy, Mrk 259 (LARS #1). This irregular galaxy shows bright and extended (indicative of resonance scattering) but strongly asymmetric Lyα emission. Spectroscopy from the Cosmic Origins Spectrograph on board HST centered on the brightest UV knot shows a moderate

  13. The Lyα reference sample. I. Survey outline and first results for Markarian 259

    Energy Technology Data Exchange (ETDEWEB)

    Östlin, Göran; Hayes, Matthew; Duval, Florent; Sandberg, Andreas; Rivera-Thorsen, Thøger; Marquart, Thomas; Adamo, Angela; Melinder, Jens; Guaita, Lucia; Micheva, Genoveva [Department of Astronomy, Stockholm University, Oscar Klein Centre, AlbaNova, Stockholm SE-106 91 (Sweden); Orlitová, Ivana [Observatoire de Genève, Université de Genève, Chemin des Maillettes 51, 1290 Versoix (Switzerland); Atek, Hakim [Laboratoire d' Astrophysique, Ecole Polytechnique Fédérale de Lausanne, Observatoire de Sauverny, CH-1290 Versoix (Switzerland); Cannon, John M.; Pardy, Stephen A. [Department of Physics and Astronomy, Macalester College, 1600 Grand Avenue, Saint Paul, MN 55105 (United States); Gruyters, Pieter [Department of Physics and Astronomy, Division of Astronomy and Space Physics, Uppsala University, Box 516, 75120 Uppsala (Sweden); Herenz, Edmund Christian [Leibniz-Institute for Astrophysics Potsdam (AIP), innoFSPEC, An der Sternwarte 16, D-14482 Potsdam (Germany); Kunth, Daniel [Institut d' Astrophysique Paris, 98bis Bd Arago, F-75014 Paris (France); Laursen, Peter [Dark Cosmology Centre, Niels Bohr Institute, University of Copenhagen, DK-2100 Copenhagen (Denmark); Mas-Hesse, J. Miguel [Centro de Astrobiologa (CSIC-INTA), Departamento de Astrofsica, POB 78, E-28691, Villanueva de la Cañada (Spain); Otí-Floranes, Héctor [Instituto de Astronoma, Universidad Nacional Autnoma de Mxico, Apdo. Postal 106, Ensenada B. C. 22800 (Mexico); and others

    2014-12-10

    The Lyα Reference Sample (LARS) is a substantial program with the Hubble Space Telescope (HST) that provides a sample of local universe laboratory galaxies in which to study the detailed astrophysics of the visibility and strength of the Lyαline of neutral hydrogen. Lyα is the dominant spectral line in use for characterizing high-redshift (z) galaxies. This paper presents an overview of the survey, its selection function, and HST imaging observations. The sample was selected from the combined GALEX+Sloan Digital Sky Survey catalog at z = 0.028-0.19, in order to allow Lyα to be captured with combinations of long-pass filters in the Solar Blind Channel (SBC) of the Advanced Camera for Surveys (ACS) onboard HST. In addition, LARS utilizes Hα and Hβ narrowband and u, b, i broadband imaging with ACS and the Wide Field Camera 3 (WFC3). In order to study galaxies in which large numbers of Lyα photons are produced (whether or not they escape), we demanded an Hα equivalent width W(Hα) ≥100 Å. The final sample of 14 galaxies covers far-UV (FUV, λ ∼ 1500 Å) luminosities that overlap with those of high-z Lyα emitters (LAEs) and Lyman break galaxies (LBGs), making LARS a valid comparison sample. We present the reduction steps used to obtain the Lyα images, including our LARS eXtraction software (LaXs), which utilizes pixel-by-pixel spectral synthesis fitting of the energy distribution to determine and subtract the continuum at Lyα. We demonstrate that the use of SBC long-pass-filter combinations increase the signal-to-noise ratio by an order of magnitude compared to the nominal Lyα filter available in SBC. To exemplify the science potential of LARS, we also present some first results for a single galaxy, Mrk 259 (LARS #1). This irregular galaxy shows bright and extended (indicative of resonance scattering) but strongly asymmetric Lyα emission. Spectroscopy from the Cosmic Origins Spectrograph on board HST centered on the brightest UV knot shows a moderate

  14. Results of a Saxitoxin Proficiency Test Including Characterization of Reference Material and Stability Studies

    Directory of Open Access Journals (Sweden)

    Kirsi Harju

    2015-11-01

    Full Text Available A saxitoxin (STX proficiency test (PT was organized as part of the Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk (EQuATox project. The aim of this PT was to provide an evaluation of existing methods and the European laboratories’ capabilities for the analysis of STX and some of its analogues in real samples. Homogenized mussel material and algal cell materials containing paralytic shellfish poisoning (PSP toxins were produced as reference sample matrices. The reference material was characterized using various analytical methods. Acidified algal extract samples at two concentration levels were prepared from a bulk culture of PSP toxins producing dinoflagellate Alexandrium ostenfeldii. The homogeneity and stability of the prepared PT samples were studied and found to be fit-for-purpose. Thereafter, eight STX PT samples were sent to ten participating laboratories from eight countries. The PT offered the participating laboratories the possibility to assess their performance regarding the qualitative and quantitative detection of PSP toxins. Various techniques such as official Association of Official Analytical Chemists (AOAC methods, immunoassays, and liquid chromatography-mass spectrometry were used for sample analyses.

  15. Development of a certified reference material for composition of high-purity copper as a transfer standard within GET 176-2013

    Directory of Open Access Journals (Sweden)

    Veniamin M. Zyskin

    2017-01-01

    Full Text Available Introduction. The paper gives information on the development of a certified reference material (CRM for composition of high-purity copper (Cu CRM UNIIM. The CRM is included as the transfer standard into the State primary standard of the mass (molar fraction and mass (molar concentration of the component in liquid and solid substances and materials based on coulometry GET 176-2013.Materials and methods. The CRM represents pieces of oxygen-free copper wire rod, brand KMB, produced according to GOST R 53803-2010, weighing from 0.5 to 1g. The CRM is packed in plastic vials with the capacity of 30 or 50 cm3. The certified characteristic of the CRM is copper mass fraction in copper wire rod, expressed in percentages. The certified value for copper mass fraction was established by the primary method of controlled-potential coulometry using the State primary standard GET 176-2013.Results. The permitted interval of the certified value for copper mass fraction in the CRM is from 99,950 % to 100,000 %. The relative expanded uncertainty (k=2 of the certified value for copper mass fraction does not exceed 0,030 %; the relative standard uncertainty due to inhomogeneity does not exceed 0.010 %; the relative standard uncertainty due to instability does not exceed 0.010 %. The shelf life of the developed CRM is 10 years provided that standard storage conditions are ensured.Discussion and conclusions. The developed CRM is included into the State register of type approved RMs under the number GSO 10800-2016. The CRM of high-purity copper (Cu CRM UNIIM as a transfer standard is intended for reproduction, storage and transfer of the copper mass fraction unit to other reference materials and chemical reagents by the method of comparison using a comparator and by conducting direct measurements. This CRM may also be used:– for verification of measuring instruments (MIs according to the state verification schedule described in GOST R 8.735.0-2014,– for calibration

  16. New Normative Database of Inner Macular Layer Thickness Measured by Spectralis OCT Used as Reference Standard for Glaucoma Detection.

    Science.gov (United States)

    Nieves-Moreno, María; Martínez-de-la-Casa, José M; Bambo, María P; Morales-Fernández, Laura; Van Keer, Karel; Vandewalle, Evelien; Stalmans, Ingeborg; García-Feijoó, Julián

    2018-02-01

    This study examines the capacity to detect glaucoma of inner macular layer thickness measured by spectral-domain optical coherence tomography (SD-OCT) using a new normative database as the reference standard. Participants ( N = 148) were recruited from Leuven (Belgium) and Zaragoza (Spain): 74 patients with early/moderate glaucoma and 74 age-matched healthy controls. One eye was randomly selected for a macular scan using the Spectralis SD-OCT. The variables measured with the instrument's segmentation software were: macular nerve fiber layer (mRNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL) volume and thickness along with circumpapillary RNFL thickness (cpRNFL). The new normative database of macular variables was used to define the cutoff of normality as the fifth percentile by age group. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) of each macular measurement and of cpRNFL were used to distinguish between patients and controls. Overall sensitivity and specificity to detect early-moderate glaucoma were 42.2% and 88.9% for mRNFL, 42.4% and 95.6% for GCL, 42.2% and 94.5% for IPL, and 53% and 94.6% for RNFL, respectively. The best macular variable to discriminate between the two groups of subjects was outer temporal GCL thickness as indicated by an AUROC of 0.903. This variable performed similarly to mean cpRNFL thickness (AUROC = 0.845; P = 0.29). Using our normative database as reference, the diagnostic power of inner macular layer thickness proved comparable to that of peripapillary RNFL thickness. Spectralis SD-OCT, cpRNFL thickness, and individual macular inner layer thicknesses show comparable diagnostic capacity for glaucoma and RNFL, GCL, and IPL thickness may be useful as an alternative diagnostic test when the measure of cpRNFL shows artifacts.

  17. Ambulatory Blood Pressure Monitoring (ABPM) as the reference standard for diagnosis of hypertension and assessment of vascular risk in adults.

    Science.gov (United States)

    Hermida, Ramón C; Smolensky, Michael H; Ayala, Diana E; Portaluppi, Francesco

    2015-01-01

    New information has become available since the ISC, AAMCC, and SECAC released their first extensive guidedelines to improve the diagnosis and treatment of adult arterial hypertension. A critical assessment of evidence and a comparison of what international guidelines now propose are the basis for the following statements, which update the recommendations first issued in 2013. Office blood pressure (BP) measurements should no longer be considered to be the "gold standard" for the diagnosis of hypertension and assessment of cardiovascular risk. Relying on office BP, even when supplemented with at-home wake-time self-measurements, to identify high-risk individuals, disregarding circadian BP patterning and asleep BP level, leads to potential misclassification of 50% of all evaluated persons. Accordingly, ambulatory BP monitoring is the recommended reference standard for the diagnosis of true hypertension and accurate assessment of cardiovascular risk in all adults ≥18 yrs of age, regardless of whether office BP is normal or elevated. Asleep systolic BP mean is the most significant independent predictor of cardiovascular events. The sleep-time relative SBP decline adds prognostic value to the statistical model that already includes the asleep systolic BP mean and corrected for relevant confounding variables. Accordingly, the asleep systolic BP mean is the recommended protocol to diagnose hypertension, assess cardiovascular risk, and predict cardiovascular event-free interval. In men, and in the absence of compelling clinical conditions, reference thresholds for diagnosing hypertension are 120/70 mmHg for the asleep systolic/diastolic BP means derived from ambulatory BP monitoring. However, in women, in the absence of complicating co-morbidities, the same thresholds are lower by 10/5 mmHg, i.e., 110/65 mmHg for the asleep means. In high-risk patients, including those diagnosed with diabetes or chronic kidney disease, and/or those having experienced past

  18. Recent applications of nuclear analytical methods to the certification of elemental content in NIST standard reference materials

    International Nuclear Information System (INIS)

    Greenberg, R.R.; Zeisler, R.; Mackey, E.A.

    2006-01-01

    Well-characterized, certified reference materials (CRMs) play an essential role in assuring the quality of analytical measurements. NIST has been producing CRMs, currently called NIST Standard Reference Materials (SRMs), to validate analytical measurements for nearly one hundred years. The predominant mode of certifying inorganic constituents in complex-matrix SRMs is through the use of two critically evaluated, independent analytical techniques at NIST. These techniques should have no significant sources of error in common. The use of nuclear analytical methods in combination with one of the chemically based analytical method at NIST eliminates the possibility of any significant, common error source. The inherent characteristics of the various forms of nuclear analytical methods make them extremely valuable for SRM certification. Instrumental NAA is nondestructive, which eliminates the possibility of any dissolution problems, and often provides homogeneity information. Radiochemical NAA typically provides nearly blank-free determinations of some highly important, but difficult elements at very low levels. Prompt-gamma NAA complements INAA, and provides independent determinations of some key elements. In addition, all significant uncertainty components can be evaluated for these techniques, and we believe these methods can meet all the requirements of a primary method of measurement as defined by ISO and the CCQM. NIST has certified several SRMs using INAA and RNAA as primary methods. In addition, NIST has compared measurements by INAA and PGAA with other primary methods as part of the CCQM intercomparisons of national metrology institutes. Some significant SRMs recently certified for inorganic constituents with contributions from the nuclear analytical methods include: Toxic Substances in Urine (SRM 2670a), Lake Superior Fish Tissue (SRM 1946), Air Particulate on Filter Media (SRM 2783), Inorganics in Marine Sediment (SRM 2702), Sediment for Solid Sampling (Small

  19. Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) with Standard Reference Line for the Analysis of Stainless Steel.

    Science.gov (United States)

    Fu, Hongbo; Dong, Fengzhong; Wang, Huadong; Jia, Junwei; Ni, Zhibo

    2017-08-01

    In this work, calibration-free laser-induced breakdown spectroscopy (CF-LIBS) is used to analyze a certified stainless steel sample. Due to self-absorption of the spectral lines from the major element Fe and the sparse lines of trace elements, it is usually not easy to construct the Boltzmann plots of all species. A standard reference line method is proposed here to solve this difficulty under the assumption of local thermodynamic equilibrium so that the same temperature value for all elements present into the plasma can be considered. Based on the concentration and rich spectral lines of Fe, the Stark broadening of Fe(I) 381.584 nm and Saha-Boltzmann plots of this element are used to calculate the electron density and the plasma temperature, respectively. In order to determine the plasma temperature accurately, which is seriously affected by self-absorption, a pre-selection procedure for eliminating those spectral lines with strong self-absorption is employed. Then, one spectral line of each element is selected to calculate its corresponding concentration. The results from the standard reference lines with and without self-absorption of Fe are compared. This method allows us to measure trace element content and effectively avoid the adverse effects due to self-absorption.

  20. Effect of polytetrafluoroethylene (PTFE) phase transition at 19°C on the use of Spectralon as a reference standard for reflectance.

    Science.gov (United States)

    Ball, Christopher P; Levick, Andrew P; Woolliams, Emma R; Green, Paul D; Dury, Martin R; Winkler, Rainer; Deadman, Andrew J; Fox, Nigel P; King, Martin D

    2013-07-10

    Sintered polytetrafluoroethylene (PTFE) is highly reflective and is widely used as a reference standard in remote sensing, radiometry, and spectroscopy. The relative change in output flux from a PTFE integrating sphere over the room temperature phase transition at 19°C has been measured at a monochromatic wavelength of 633 nm as 1.82±0.21%. The change in output flux was attributed to a small change of 0.09±0.02% in the total hemispherical reflectance of PTFE, caused by a change in its material density as a result of the phase transition. For the majority of users, this small change measured in total hemispherical reflectance is unlikely to impact significantly the accuracy of PTFE flat panel reflectors used as reference standards. However, owing to the multiple reflections that occur inside an integrating sphere cavity, the effect is multiplied and remedial action should be applied, either via a mathematical correction or through temperature stabilization of the integrating sphere when high accuracy (PTFE-based integrating spheres at temperatures close to the phase transition at 19°C.

  1. Detection of heart rate and rhythm with a smartphone-based electrocardiograph versus a reference standard electrocardiograph in dogs and cats.

    Science.gov (United States)

    Kraus, Marc S; Gelzer, Anna R; Rishniw, Mark

    2016-07-15

    OBJECTIVE To evaluate the diagnostic utility of ECGs acquired with a smartphone-based device, compared with reference 6-lead ECGs, for identification of heart rate and rhythm in dogs and cats. DESIGN Prospective study. ANIMALS 51 client-owned dogs and 27 client-owned cats. PROCEDURES Patients examined by a small animal referral cardiology service between April 2012 and January 2013 were enrolled consecutively. In each patient, a 30-second ECG was simultaneously acquired with a smartphone-based device (a bipolar, single-lead recorder coupled to a smartphone with an ECG application) and a standard 6-lead ECG machine. Recordings were evaluated by 3 board-certified cardiologists, and intra- and interobserver agreement were evaluated for both rhythm diagnosis and QRS polarity identification. RESULTS Values for instantaneous and mean heart rates for the smartphone-acquired and reference ECGs were within 1 beat of each other when mean heart rates were calculated. Intraobserver agreement for rhythm assessment was very high, with maximum disagreement for any observer for only 2 of 51 dogs and only 4 of 27 cats. There was minimal disagreement in the polarity of depolarization between the smartphone-acquired and reference ECGs in dogs but frequent disagreement in cats. Interobserver agreement for smartphone-acquired ECGs was similar to that for reference ECGs. with all 3 observers agreeing on the rhythm analysis and minimal disagreement on polarity. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that ECGs acquired with the smartphone-based device accurately identified heart rate and rhythm in dogs and cats. Thus, the device may allow veterinarians to evaluate and manage cardiac arrhythmias relatively inexpensively at the cage side and could also allow clinicians to rapidly share information via email for further consultation, potentially enhancing patient care.

  2. Results from a CFD reference study into the modelling of heat and smoke transport by different CFD-practitioners

    NARCIS (Netherlands)

    Loomans, M.G.L.C.; Lemaire, A.D.; Plas, van der M.

    2009-01-01

    The paper describes results from a reference study that focuses on the application of the Computational Fluid Dynamics (CFD-) technique for heat and smoke transport in practice. Goal of the study is to obtain insight into the amount and causes of the spread of CFD-results when applied by different

  3. Evaluation of serological diagnostic tests for typhoid fever in Papua New Guinea using a composite reference standard.

    Science.gov (United States)

    Siba, Valentine; Horwood, Paul F; Vanuga, Kilagi; Wapling, Johanna; Sehuko, Rebecca; Siba, Peter M; Greenhill, Andrew R

    2012-11-01

    Typhoid fever remains a major global health problem. A major impediment to improving outcomes is the lack of appropriate diagnostic tools, which have not significantly improved in low-income settings for 100 years. We evaluated two commercially available rapid diagnostic tests (Tubex and TyphiDot), a prototype (TyphiRapid TR-02), and the commonly used single-serum Widal test in a previously reported high-burden area of Papua New Guinea. Samples were collected from 530 outpatients with axillary temperatures of ≥37.5°C, and analysis was conducted on all malaria-negative samples (n = 500). A composite reference standard of blood culture and PCR was used, by which 47 participants (9.4%) were considered typhoid fever positive. The sensitivity and specificity of the Tubex (51.1% and 88.3%, respectively) and TyphiDot (70.0% and 80.1%, respectively) tests were not high enough to warrant their ongoing use in this setting; however, the sensitivity and specificity for the TR-02 prototype were promising (89.4% and 85.0%, respectively). An axillary temperature of ≥38.5°C correlated with typhoid fever (P = 0.014). With an appropriate diagnostic test, conducting typhoid fever diagnosis only on patients with high-grade fever could dramatically decrease the costs associated with diagnosis while having no detrimental impact on the ability to accurately diagnose the illness.

  4. KoVariome: Korean National Standard Reference Variome database of whole genomes with comprehensive SNV, indel, CNV, and SV analyses.

    Science.gov (United States)

    Kim, Jungeun; Weber, Jessica A; Jho, Sungwoong; Jang, Jinho; Jun, JeHoon; Cho, Yun Sung; Kim, Hak-Min; Kim, Hyunho; Kim, Yumi; Chung, OkSung; Kim, Chang Geun; Lee, HyeJin; Kim, Byung Chul; Han, Kyudong; Koh, InSong; Chae, Kyun Shik; Lee, Semin; Edwards, Jeremy S; Bhak, Jong

    2018-04-04

    High-coverage whole-genome sequencing data of a single ethnicity can provide a useful catalogue of population-specific genetic variations, and provides a critical resource that can be used to more accurately identify pathogenic genetic variants. We report a comprehensive analysis of the Korean population, and present the Korean National Standard Reference Variome (KoVariome). As a part of the Korean Personal Genome Project (KPGP), we constructed the KoVariome database using 5.5 terabases of whole genome sequence data from 50 healthy Korean individuals in order to characterize the benign ethnicity-relevant genetic variation present in the Korean population. In total, KoVariome includes 12.7M single-nucleotide variants (SNVs), 1.7M short insertions and deletions (indels), 4K structural variations (SVs), and 3.6K copy number variations (CNVs). Among them, 2.4M (19%) SNVs and 0.4M (24%) indels were identified as novel. We also discovered selective enrichment of 3.8M SNVs and 0.5M indels in Korean individuals, which were used to filter out 1,271 coding-SNVs not originally removed from the 1,000 Genomes Project when prioritizing disease-causing variants. KoVariome health records were used to identify novel disease-causing variants in the Korean population, demonstrating the value of high-quality ethnic variation databases for the accurate interpretation of individual genomes and the precise characterization of genetic variations.

  5. Lung function in North American Indian children: reference standards for spirometry, maximal expiratory flow volume curves, and peak expiratory flow.

    Science.gov (United States)

    Wall, M A; Olson, D; Bonn, B A; Creelman, T; Buist, A S

    1982-02-01

    Reference standards of lung function was determined in 176 healthy North American Indian children (94 girls, 82 boys) 7 to 18 yr of age. Spirometry, maximal expiratory flow volume curves, and peak expiratory flow rate were measured using techniques and equipment recommended by the American Thoracic Society. Standing height was found to be an accurate predictor of lung function, and prediction equations for each lung function variable are presented using standing height as the independent variable. Lung volumes and expiratory flow rates in North American Indian children were similar to those previously reported for white and Mexican-American children but were greater than those in black children. In both boys and girls, lung function increased in a curvilinear fashion. Volume-adjusted maximal expiratory flow rates after expiring 50 or 75% of FVC tended to decrease in both sexes as age and height increased. Our maximal expiratory flow volume curve data suggest that as North American Indian children grow, lung volume increases at a slightly faster rate than airway size does.

  6. Comparing the role of standard references on the prevalence of Iranian children and adolescents' overweight and obesity: A systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Saeed Ghanbari

    2016-01-01

    Full Text Available Background: Obesity is a major risk factor for chronic diseases and has a role on high blood pressure, diabetes type II, etc., This review assesses the prevalence of Iranian children obesity and overweight for different age categories and compares the three standard definitions of obesity. Materials and Methods: To retrieve desirable studies concerning childhood anthropometric data from different area of Iran, the MEDLINE, Scopus, and different local databases such as Scientific Information database were used. The studies reported the prevalence of obesity or overweight of children < 6, 6–12, and 12–20 years old, despite differences between definitions of childhood obesity, were included in the study. We combined the reported prevalence of the overweight and obesity with regard to age and gender, and also by the different standard references which are the Centers for Disease Control and Prevention (CDC, the World Health Organization (WHO definition, and the International Obesity Task Force (IOTF references. The analysis was carried out using STATA software. Results: Our review covered 75 articles reported the prevalence of overweight or obesity among children and adolescents for different age groups in Iran. Our meta-regression analysis showed that the prevalence of obesity and overweight did not vary significantly in gender and age categories, but different definitions provide different prevalence of overweight and obesity. Conclusion: The effective factors on obesity and overweight included administration policy and organizational, interpersonal, intrapersonal, and social factors. CDC and WHO references intended in monitoring children's growth and the IOTF cutoffs would rather provide a common set of definitions that researchers and policymakers could use for descriptive and comparative purposes.

  7. Standard Test Method for Calibration of Primary Non-Concentrator Terrestrial Photovoltaic Reference Cells Using a Tabular Spectrum

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method is intended to be used for calibration and characterization of primary terrestrial photovoltaic reference cells to a desired reference spectral irradiance distribution, such as Tables G173. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of photovoltaic devices. 1.2 Primary photovoltaic reference cells are calibrated in natural sunlight using the relative spectral response of the cell, the relative spectral distribution of the sunlight, and a tabulated reference spectral irradiance distribution. 1.3 This test method requires the use of a pyrheliometer that is calibrated according to Test Method E816, which requires the use of a pyrheliometer that is traceable to the World Radiometric Reference (WRR). Therefore, reference cells calibrated according to this test method are traceable to the WRR. 1.4 This test method is a technique that may be used ...

  8. End-Use Opportunity Analysis from Progress Indicator Results for ASHRAE Standard 90.1-2013

    Energy Technology Data Exchange (ETDEWEB)

    Hart, Philip R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Xie, YuLong [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-01

    This report and an accompanying spreadsheet (PNNL 2014a) compile the end use building simulation results for prototype buildings throughout the United States. The results represent he energy use of each edition of ASHRAE Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings (ASHRAE 2004, 2007, 2010, 2013). PNNL examined the simulation results to determine how the remaining energy was used.

  9. Modeling of radionuclide transport through rock formations and the resulting radiation exposure of reference persons. Calculations using Asse II parameters

    International Nuclear Information System (INIS)

    Kueppers, Christian; Ustohalova, Veronika; Steinhoff, Mathias

    2012-01-01

    The long-term release of radioactivity into the ground water path cannot be excluded for the radioactive waste repository Asse II. The possible radiological consequences were analyzed using a radio-ecological scenario developed by GRS. A second scenario was developed considering the solubility of radionuclides in salt saturated solutions and retarding/retention effects during the radionuclide transport through the cap rock layers. The modeling of possible radiation exposure was based on the lifestyle habits of reference persons. In Germany the calculation procedure for the prediction of radionuclide release from final repositories is not defined by national standards, the used procedures are based on analogue methods from other radiation protection calculations.

  10. Preparation of a multi-isotope plutonium AMS standard and preliminary results of a first inter-lab comparison

    Energy Technology Data Exchange (ETDEWEB)

    Dittmann, B.-A.; Dunai, T.J. [Institute of Geology and Mineralogy, University of Cologne, Greinstr. 4-6, 50939 Cologne (Germany); Dewald, A.; Heinze, S.; Feuerstein, C. [Institute of Nuclear Physics, University of Cologne, Zülpicher Str. 77, 50937 Cologne (Germany); Strub, E. [Division of Nuclear Chemistry, University of Cologne, Zülpicher Str. 45, 50674 Cologne (Germany); Fifield, L.K.; Froehlich, M.B.; Tims, S.G.; Wallner, A. [Department of Nuclear Physics, Research School of Physics & Engineering, Australian National University, Canberra ACT 2601 (Australia); Christl, M. [Laboratory of Ion Beam Physics, ETH Zurich, Otto-Stern-Weg 5, 8093 Zurich (Switzerland)

    2015-10-15

    The motivation of this work is to establish a new multi-isotope plutonium standard for isotopic ratio measurements with accelerator mass spectrometry (AMS), since stocks of existing solutions are declining. To this end, certified reference materials (CRMs) of each of the individual isotopes {sup 239}Pu, {sup 240}Pu, {sup 242}Pu and {sup 244}Pu were obtained from JRC IRMM (Joint Research Center Institute for Reference Materials and Measurements). These certified reference materials (IRMM-081a, IRMM-083, IRMM-043 and IRMM-042a) were diluted with nitric acid and mixed to obtain a stock standard solution with an isotopic ratio of approximately 1.0:1.0:1.0:0.1 ({sup 239}Pu:{sup 240}Pu:{sup 242}Pu:{sup 244}Pu). From this stock solution, samples were prepared for measurement of the plutonium isotopic composition by AMS. These samples have been measured in a round-robin exercise between the AMS facilities at CologneAMS, at the ANU Canberra and ETH Zurich to verify the isotopic ratio and to demonstrate the reproducibility of the measurements. The results show good agreement both between the different AMS measurements and with the gravimetrically determined nominal ratios.

  11. Catalogue of EDF`s technical specifications (HN reference). Centre of standardization; Catalogue des specifications techniques EDF (reference HN). Centre de normalisation

    Energy Technology Data Exchange (ETDEWEB)

    1998-12-31

    This document edited by Electricite de France (EdF), is a catalogue of the French standard documents relative to any type of electrical material and equipment and which contain the technical specifications of these materials and equipments. A brief description of these specifications is given for each type of material or equipment listed. (J.S.)

  12. The development of methodological tools to assess the health sector with the resulting standardized index

    Directory of Open Access Journals (Sweden)

    Hansuvarova Evgenia Adolfovna

    2016-10-01

    The proposed assessment methodology resulting standardized health index in the various countries of the world allows you to define the country implementing an effective management strategy in the health sector. The leading positions belong to the countries where the state health policy has shown its greatest efficiency. This technique can be used not only for point scoring result of a standardized health index in the world, but also to assess in a particular country.

  13. Test imf kursus - Referred Pain and Sensations Evoked by Standardized Palpation of the Masseter Muscle in Healthy Participants

    DEFF Research Database (Denmark)

    Masuda, Manabu; Iida, Takashi; Exposto, Fernando G

    2018-01-01

    , Tukey post hoc, and McNemar's tests with a 5% level of significance. RESULTS: Referred pain/sensations were most commonly evoked with the 2.0-kg stimulus (34.4% of participants; P significant effects of stimulus intensity on NRS...... scores for pain and unpleasantness, as well as for aftersensation (P significant effects on NRS scores for pain and unpleasantness for the 1.0- and 2.0-kg stimuli (P 2.0-kg stimulus (P .... The right masseter muscle was divided into 15 test sites. Mechanical sensitivity of the masseter was assessed with three mechanical stimuli (0.5 kg, 1.0 kg, or 2.0 kg) applied by palpometers to the 15 test sites for 5 seconds each site. Participants scored the perceived intensity of pain and unpleasantness...

  14. Diagnostic accuracy of direct ophthalmoscopy for detection of diabetic retinopathy using fundus photographs as a reference standard.

    Science.gov (United States)

    Ahsan, Shahid; Basit, Abdul; Ahmed, Kazi Rumana; Ali, Liaquat; Shaheen, Fariha; Ulhaque, Muhammad Saif; Fawwad, Asher

    2014-01-01

    To determine the diagnostic accuracy of direct ophthalmoscopy for the presence and severity of diabetic retinopathy (DR) using fundus photographs as a reference standard. Patients with type 2 diabetes attending the outpatient department (OPD) of a tertiary care diabetes center, from October 2009 to March 2010 were recruited in the study after obtaining signed informed consent. Patients with type 1 diabetes and gestational diabetes or having eye problems were excluded. After checking visual acuity, direct ophthalmoscopy of each eye was done by diabetologist, followed by photography of two fields of retina by fundus camera. DR was graded by a retinal specialist, according to International Diabetic Retinopathy Disease Severity Scale. According to severity, patients with DR were grouped into non-sight threatening diabetic retinopathy (NSTDR) and sight threatening diabetic retinopathy (STDR). Sensitivity and specificity of direct ophthalmoscopy for detection of any retinopathy, NSTDR and STDR was calculated. A total of 728 eyes were examined by direct ophthalmoscopy as well as fundus photography. Sensitivity (95% CI) of direct ophthalmoscopy for any retinopathy, NSTDR and STDR was found to be 55.67% (50.58-60.78), 37.63% (32.67-42.59) and 68.25% (63.48-73.02) respectively. Whereas, specificity of direct ophthalmoscopy was found to be 76.78% (72.45-81.11), 71.27% (CI: 66.63-75.91) and 90.0% (86.93-93.07) for any retinopathy, NSTDR and STDR respectively. The sensitivity and specificity of direct ophthalmoscopy performed by the diabetologist for the presence and severity of DR was lower compared to the recommended level of sensitivity and specificity of a screening test of DR. Copyright © 2014 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  15. A laboratory study on formation of oil-SPM aggregates using the NIST standard reference material 1941b. Volume 1

    International Nuclear Information System (INIS)

    Khelifa, A.; Fieldhouse, B.; Wang, Z.; Yang, C.; Landriault, M.; Fingas, M.; Brown, C.E.; Gamble, L.; Pjontek, D.

    2007-01-01

    The dispersion of spilled oil in water can be enhanced by a natural process in which suspended particulate matter (SPM) combines with oil droplets to form Oil-SPM aggregates (OSA). A laboratory setup and procedure were developed in this study to examine the formation of OSAs in which the sediment (Standard Reference Material 1941b) was mixed with Arabian Medium, Alaska North Slope and South Louisiana crudes at concentrations varying from 25 to 300 mg/L. The OSAs were separated from the bulk water using a newly developed procedure. Gas chromatography combined with flame ionization analysis was used to measure the oil trapped in the OSAs. The sediment trapped in the sinking OSAs was then isolated for gravimetric quantification. This procedure has the potential to isolate sinking OSAs with minimum alteration with dispersed oil. Oil mass of less than 2 mg trapped in OSAs was measured with 0.8 mg uncertainty at a 95 per cent confidence level. This setup was capable of imaging droplets of 0.1 μg and up in size. The study showed that formation of sinking OSAs reaches maximum efficiency at an optimum oil to sediment ratio that decreases from 0.5 to approximately 0.1 when the ratio between oil density and the water density increases from 0.84 to 0.97. The percentage of oil trapped in sinking OSAs increases quickly from approximately 0.5 per cent to 30 per cent of the initial oil mass when sediment concentration increases from 25 to 100 mg/l. The highest trapping efficiency was found to decrease exponentially with oil density. 33 refs., 2 tabs., 12 figs

  16. Standard Reference Line Combined with One-Point Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) to Quantitatively Analyze Stainless and Heat Resistant Steel.

    Science.gov (United States)

    Fu, Hongbo; Wang, Huadong; Jia, Junwei; Ni, Zhibo; Dong, Fengzhong

    2018-01-01

    Due to the influence of major elements' self-absorption, scarce observable spectral lines of trace elements, and relative efficiency correction of experimental system, accurate quantitative analysis with calibration-free laser-induced breakdown spectroscopy (CF-LIBS) is in fact not easy. In order to overcome these difficulties, standard reference line (SRL) combined with one-point calibration (OPC) is used to analyze six elements in three stainless-steel and five heat-resistant steel samples. The Stark broadening and Saha - Boltzmann plot of Fe are used to calculate the electron density and the plasma temperature, respectively. In the present work, we tested the original SRL method, the SRL with the OPC method, and intercept with the OPC method. The final calculation results show that the latter two methods can effectively improve the overall accuracy of quantitative analysis and the detection limits of trace elements.

  17. Reference standards for quantitative trace analysis of PCB's by GC. Technical PCB formulations for the calibration of ECD and MSD responses

    Energy Technology Data Exchange (ETDEWEB)

    Krupcik, J. (Slovak Technical Univ., Department of Analytical Chemistry, Bratislava (Slovakia)); Kocan, A. (Institute of Preventive Medicine, Bratislava (Slovakia)); Petrik, J. (Institute of Preventive Medicine, Bratislava (Slovakia)); Leclercq, P.A. (Eindhoven University of Technology, Dept. of Chemical Engineering, Lab. of Instrumental Analysis (Netherlands)); Ballschmiter, K. (University of Ulm, Dept. of Analytical and Environmental Chemistry (Germany))

    1993-04-01

    The composition of any technical PCB formulation can be determined directly by analyzing the PCB sample by gas chromatography with a flame ionization detector (GC-FID), provided the relative molecular masses of the components are known. The response of electron capture and selected-ion monitoring, mass-spectra detectors can then be calibrated for individual PCB congeners by correlation of the chromatographic patterns with those of concentrated PCB samples obtained by GC-FID. This procedure, which uses a given technical PCB formulation as a secondary reference standard mixture, is to be preferred over existing calibration methods, when results with [+-]10% errors are acceptable because commercial PCB formulations cover the whole range of chlorination products. (orig.)

  18. Evaluation of Methacholine Challenge Test Results in Chronic Cough Patients Referring to Clinic of Pulmonary Disease

    Directory of Open Access Journals (Sweden)

    Derakhshan Deilami Gholamreza

    2009-10-01

    Full Text Available Chronic cough is a common problem in patients visiting physicians and its prevalence in different populations range from 3 to 40%. Postnasal drip, asthma and gastroesophageal reflux are the known cause of chronic cough. Although diagnosis of asthma is usually made by clinical signs and spirometeric results, methacholine challenge test is a good diagnostic test in patients who show normal physical examination and spirometeric results. In this study, the results of methacholine challenge test in chronic cough patients are investigated. This is a cross sectional study performed on patients suffering from chronic cough (over 8 weeks, who went to Pulmonary Disease Clinic of Imam Khomeini Hospital in 2006. Postnasal drip, gastroesophageal reflux was evaluated and ruled out in all patients. Then they were tested by methacholine inhalation using low to high doses of methacholine. The results of test was defined as 20% fall in FEV1 and its relationship with age, sex, history of allergic disease, family history of asthma and smoking status was investigated. 81 patients (36 female and 45 male entered this study who had mean age of 32.5 ± 13.06 years. 81.5% of patients had never smoked or closed contact with smokers, 6.2% were passive smokers, 8.6% were smokers and 3.7% had quit smoking. 37% had suffered from chronic cough less than 6 months, 11% for 6-11 months and 52% for more than 12 months. In 26% of patients, family history of asthma was present and 34.5% had a history of one type of allergy. In 29.5% the results of methacholine challenge test was positive, among them 45.8% showed an intense response and 54.2% a moderate response. The test results and its intensity had no statistically significant relationship with age, sex, smoking status, the duration of cough and family history of asthma, but the relationship between methacholine challenge test and the history of allergic disease was significant. Methacholine challenge test can be used as a

  19. Standardization of uveitis nomenclature for reporting clinical data. Results of the First International Workshop.

    Science.gov (United States)

    Jabs, Douglas A; Nussenblatt, Robert B; Rosenbaum, James T

    2005-09-01

    To begin a process of standardizing the methods for reporting clinical data in the field of uveitis. Consensus workshop. Members of an international working group were surveyed about diagnostic terminology, inflammation grading schema, and outcome measures, and the results used to develop a series of proposals to better standardize the use of these entities. Small groups employed nominal group techniques to achieve consensus on several of these issues. The group affirmed that an anatomic classification of uveitis should be used as a framework for subsequent work on diagnostic criteria for specific uveitic syndromes, and that the classification of uveitis entities should be on the basis of the location of the inflammation and not on the presence of structural complications. Issues regarding the use of the terms "intermediate uveitis," "pars planitis," "panuveitis," and descriptors of the onset and course of the uveitis were addressed. The following were adopted: standardized grading schema for anterior chamber cells, anterior chamber flare, and for vitreous haze; standardized methods of recording structural complications of uveitis; standardized definitions of outcomes, including "inactive" inflammation, "improvement'; and "worsening" of the inflammation, and "corticosteroid sparing," and standardized guidelines for reporting visual acuity outcomes. A process of standardizing the approach to reporting clinical data in uveitis research has begun, and several terms have been standardized.

  20. Quality control of achieved results of testings in interlaboratory reference measurements

    International Nuclear Information System (INIS)

    Rosskopfova, O.; Matel, L.; Rajec, P.

    2009-01-01

    The laboratory accredited according to the ISO/IEC 17025:2005 must ensure the quality of reported results including corresponding uncertainty. The important point of view of correct evaluation of results is precision and uncertainty. The validation of a method is an experimental verification and an objective proof that the method is suitable for planned application. The most frequent way of validation is a participation in an intercomparison test. LARCHA laboratory regularly participates in the proficiency tests on the determination of gamma, beta and alpha emitting radionuclides in various matrices. It is also a proof for the laboratory and client that the methods for radionuclides determination are validated according to the rules of ISO/IEC 17025:2005. (authors)

  1. 38 CFR 0.735-10 - Cross-reference to employee ethical and other conduct standards and financial disclosure...

    Science.gov (United States)

    2010-07-01

    ... employee ethical and other conduct standards and financial disclosure regulations. 0.735-10 Section 0.735-10 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS STANDARDS OF ETHICAL CONDUCT AND RELATED RESPONSIBILITIES Standards of Ethical Conduct and Related Responsibilities of...

  2. Colostomy irrigation: results of 25 cases with particular reference to quality of life.

    Science.gov (United States)

    Karadağ, Ayişe; Menteş, B Bülent; Ayaz, Sultan

    2005-04-01

    The aim of this study was to document our results with colostomy irrigation with particular emphasis on the possible contribution of irrigation on quality of life. Colostomy irrigation is a useful method of achieving faecal continence in selected conditions, and may improve quality of life. When successful, irrigation offers a regular, predictable elimination pattern and only a small covering is needed for security between irrigations. The digestive disease quality of life questionnaire-15 (DDQ-15) and Short Form-36 were used to analyse quality of life before and 12 months after stomatherapy in a series of 25 irrigating patients with permanent end colostomies. During the same time period, 10 similar patients with left-end colostomies who also received counselling but did not consent to colostomy irrigation were also analysed for comparison. Colostomy irrigation was found to be effective for achieving faecal continence in selected patients with end colostomies with no complications or significant side-effects, The digestive disease quality of life questionnaire-15 score improved significantly in both groups after stomatherapy (P colostomy irrigation can be a useful method of achieving faecal continence in selected conditions, it is safe, and it may help improve many aspects of quality of life. Colostomy irrigation is free from complications and significant side-effects, and it may serve as a useful adjunct to conventional stomatherapy. Therefore, the enterostomal therapy nurse should assess the appropriateness of routine irrigation as a method of stoma management for patients with left-end colostomy.

  3. Estrogen and progesterone receptor testing in breast carcinoma: concordance of results between local and reference laboratories in Brazil

    Directory of Open Access Journals (Sweden)

    Sheila Cristina Lordelo Wludarski

    Full Text Available CONTEXT AND OBJECTIVE: Breast cancer accounts for approximately one quarter of all cancers in females. Estrogen and progesterone receptor testing has become an essential part of the clinical evaluation of breast carcinoma patients, and accurate results are critical in identifying patients who may benefit from hormone therapy. The present study had the aim of investigating the concordance of the results from hormone receptor tests between a reference laboratory and local (or community laboratories in Brazil. DESIGN AND SETTING: Retrospective study at a reference pathology laboratory. METHODS: The concordance in the results from hormone receptor tests between a reference laboratory and 146 local laboratories in Brazil was compared in relation to 500 invasive breast carcinoma cases, using immunohistochemistry. RESULTS: There was concordance in 89.4% (447/500 cases and 85.0% (425/500 cases of the results from estrogen (κ = 0.744, P < 0.001 and progesterone (κ = 0.688, P < 0.001 receptor tests, respectively, between local and reference laboratories. This was similar to findings in other countries. The false negative rates from estrogen and progesterone receptor tests in local laboratories were 8.7% and 14.4%, respectively. The false positive rates from estrogen and progesterone receptor tests in local laboratories were 15.5% and 16.0%, respectively. CONCLUSION: Technical and result interpretation issues may explain most of the discordances in hormone receptor testing in local laboratories. Validation of estrogen and progesterone receptor tests at local laboratories, with rigorous quality control measures, is strongly recommended in order to avoid erroneous treatment of breast cancer patients.

  4. Added value of cardiac computed tomography for evaluation of mechanical aortic valve: Emphasis on evaluation of pannus with surgical findings as standard reference.

    Science.gov (United States)

    Suh, Young Joo; Lee, Sak; Im, Dong Jin; Chang, Suyon; Hong, Yoo Jin; Lee, Hye-Jeong; Hur, Jin; Choi, Byoung Wook; Chang, Byung-Chul; Shim, Chi Young; Hong, Geu-Ru; Kim, Young Jin

    2016-07-01

    The added value of cardiac computed tomography (CT) with transesophageal echocardiography (TEE) for evaluating mechanical aortic valve (AV) dysfunction has not yet been investigated. The purposes of this study were to investigate the added value of cardiac CT for evaluation of mechanical AVs and diagnoses of pannus compared to TEE, with surgical findings of redo-aortic valve replacement (AVR) used as a standard reference. 25 patients who underwent redo-AVR due to mechanical AV dysfunction and cardiac CT before redo-AVR were included. The presence of pannus, encroachment ratio by pannus, and limitation of motion (LOM) were evaluated on CT. The diagnostic performance of pannus detection was compared using TEE, CT, and CT+TEE, with surgical findings as a standard reference. The added value of CT for diagnosing the cause of mechanical AV dysfunction was assessed compared to TTE+TEE. In two patients, CT analysis was not feasible due to severe metallic artifacts. On CT, pannus and LOM were found in 100% (23/23) and 60.9% (14/23). TEE identified pannus in 48.0% of patients (12/25). CT, TEE, and CT+TEE correctly identified pannus with sensitivity of 92.0%, 48.0%, and 92.0%, respectively (P=0.002 for CT vs. TEE). In 11 of 13 cases (84.6%) with inconclusive or negative TEE results for pannus, CT detected the pannus. Among 13 inconclusive cases of TTE+TEE for the cause of mechanical AV dysfunction, CT suggested 6 prosthetic valve obstruction (PVO) by pannus, 4 low-flow low-gradient PVO, and one LOM without significant PVO. Cardiac CT showed added diagnostic value with TEE in the detection of pannus as the cause of mechanical AV dysfunction. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Quantification of pneumothorax volume on chest radiographs: comparison between the collins' and the axel's methods with three-dimensional CT as the standard of reference

    International Nuclear Information System (INIS)

    Lee, Chang Keun; Kim, Hyung Jin; Lee, Kyung Hee; Kim, Joung Taek; Kim, Kwang Ho; Suh, Chang Hae; Han, Heon

    1999-01-01

    The purpose of this study was twofold. In a preliminary study, we evaluated the accuracy of 3-D (three-dimensional) CT for the estimation of pneumothorax volume and for providing the optimal postprocessing method for clinical study. In the clinical study, we determined which of the two methods, Collins' and Axel's, was more accurate for the estimation of pneumothorax volume, as seen on chest radiographs, using 3-D CT as the standard of reference. In the preliminary study, 3-D CT was applied to phantoms and to four patients with pneumothorax using two different postprocessing methods, manual contour delineation and thresholding. In the clinical study, 3-D CT was performed in 13 patients with pneumothorax. For the purpose of evaluating conventional radiographs, a localizer scan was used for comparing the accuracy of Collins' method with that of Axel's method, with 3-D CT as the standard of reference. The preliminary study revealed that 3-D CT estimated pneumothorax volume with great accuracy and that manual contour delineation and thresholding measured volume equally well. Because of the shorter postprocessing time required with thresholding than with manual contour delineation (5 min versus 30 min), the former was used during clinical study. The results of this indicated close correlation between the measurements obtained using Collins' method on chest radiographs and those obtained by 3-D CT(r=0.95, p 0.05). 3-D CT can estimate pneumothorax volume with great accuracy. Collins' method is superior to Axel's method for the quantification of pneumothorax volume as seen on chest radiographs

  6. Use of fat mass and fat free mass standard deviation scores obtained using simple measurement methods in healthy children and patients: comparison with the reference 4-component model.

    Directory of Open Access Journals (Sweden)

    Rachel R Atherton

    Full Text Available BACKGROUND: Clinical application of body composition (BC measurements for individual children has been limited by lack of appropriate reference data. OBJECTIVES: (1 To compare fat mass (FM and fat free mass (FFM standard deviation scores (SDS generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C model; (2 To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. DESIGN: FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy, BMI and skinfold thicknesses (SFT; and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height(2/Z in 927 subjects aged 3.8-22.0 y (211 healthy, 716 patients. RESULTS: DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement FM SDS 0.03 (± 0.62; FFM SDS -0.04 (± 0.72, and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤-2 or ≥ 2. BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. CONCLUSIONS: DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome.

  7. Unstable Expression of Commonly Used Reference Genes in Rat Pancreatic Islets Early after Isolation Affects Results of Gene Expression Studies.

    Directory of Open Access Journals (Sweden)

    Lucie Kosinová

    Full Text Available The use of RT-qPCR provides a powerful tool for gene expression studies; however, the proper interpretation of the obtained data is crucially dependent on accurate normalization based on stable reference genes. Recently, strong evidence has been shown indicating that the expression of many commonly used reference genes may vary significantly due to diverse experimental conditions. The isolation of pancreatic islets is a complicated procedure which creates severe mechanical and metabolic stress leading possibly to cellular damage and alteration of gene expression. Despite of this, freshly isolated islets frequently serve as a control in various gene expression and intervention studies. The aim of our study was to determine expression of 16 candidate reference genes and one gene of interest (F3 in isolated rat pancreatic islets during short-term cultivation in order to find a suitable endogenous control for gene expression studies. We compared the expression stability of the most commonly used reference genes and evaluated the reliability of relative and absolute quantification using RT-qPCR during 0-120 hrs after isolation. In freshly isolated islets, the expression of all tested genes was markedly depressed and it increased several times throughout the first 48 hrs of cultivation. We observed significant variability among samples at 0 and 24 hrs but substantial stabilization from 48 hrs onwards. During the first 48 hrs, relative quantification failed to reflect the real changes in respective mRNA concentrations while in the interval 48-120 hrs, the relative expression generally paralleled the results determined by absolute quantification. Thus, our data call into question the suitability of relative quantification for gene expression analysis in pancreatic islets during the first 48 hrs of cultivation, as the results may be significantly affected by unstable expression of reference genes. However, this method could provide reliable information

  8. Official ERS technical standards: Global Lung Function Initiative reference values for the carbon monoxide transfer factor for Caucasians.

    Science.gov (United States)

    Stanojevic, Sanja; Graham, Brian L; Cooper, Brendan G; Thompson, Bruce R; Carter, Kim W; Francis, Richard W; Hall, Graham L

    2017-09-01

    There are numerous reference equations available for the single-breath transfer factor of the lung for carbon monoxide ( T  LCO ); however, it is not always clear which reference set should be used in clinical practice. The aim of the study was to develop the Global Lung Function Initiative (GLI) all-age reference values for T  LCO Data from 19 centres in 14 countries were collected to define T  LCO reference values. Similar to the GLI spirometry project, reference values were derived using the LMS (lambda, mu, sigma) method and the GAMLSS (generalised additive models for location, scale and shape) programme in R.12 660 T  LCO measurements from asymptomatic, lifetime nonsmokers were submitted; 85% of the submitted data were from Caucasians. All data were uncorrected for haemoglobin concentration. Following adjustments for elevation above sea level, gas concentration and assumptions used for calculating the anatomic dead space volume, there was a high degree of overlap between the datasets. Reference values for Caucasians aged 5-85 years were derived for T  LCO , transfer coefficient of the lung for carbon monoxide and alveolar volume.This is the largest collection of normative T  LCO data, and the first global reference values available for T  LCO . Copyright ©ERS 2017.

  9. Impact of the choice of the precipitation reference data set on climate model selection and the resulting climate change signal

    Science.gov (United States)

    Gampe, D.; Ludwig, R.

    2017-12-01

    Regional Climate Models (RCMs) that downscale General Circulation Models (GCMs) are the primary tool to project future climate and serve as input to many impact models to assess the related changes and impacts under such climate conditions. Such RCMs are made available through the Coordinated Regional climate Downscaling Experiment (CORDEX). The ensemble of models provides a range of possible future climate changes around the ensemble mean climate change signal. The model outputs however are prone to biases compared to regional observations. A bias correction of these deviations is a crucial step in the impact modelling chain to allow the reproduction of historic conditions of i.e. river discharge. However, the detection and quantification of model biases are highly dependent on the selected regional reference data set. Additionally, in practice due to computational constraints it is usually not feasible to consider the entire ensembles of climate simulations with all members as input for impact models which provide information to support decision-making. Although more and more studies focus on model selection based on the preservation of the climate model spread, a selection based on validity, i.e. the representation of the historic conditions is still a widely applied approach. In this study, several available reference data sets for precipitation are selected to detect the model bias for the reference period 1989 - 2008 over the alpine catchment of the Adige River located in Northern Italy. The reference data sets originate from various sources, such as station data or reanalysis. These data sets are remapped to the common RCM grid at 0.11° resolution and several indicators, such as dry and wet spells, extreme precipitation and general climatology, are calculate to evaluate the capability of the RCMs to produce the historical conditions. The resulting RCM spread is compared against the spread of the reference data set to determine the related uncertainties and

  10. Results on Standard Model Higgs Boson searches at high mass at the LHC

    International Nuclear Information System (INIS)

    Gao, Yanyan

    2014-01-01

    We present results from searches for the standard model Higgs boson with a mass greater than 200 GeV in pp collisions at √(s)=7 TeV. The data are collected at the LHC with both ATLAS and CMS detectors, and correspond to integrated luminosity of 5 fb -1 each. Searches are performed in the 2 main decay modes WW and ZZ. No significant excess of events above the standard model background expectations is observed, and upper limits on the Higgs boson production relative to the standard model expectation are derived. A standard model Higgs boson is excluded in the mass range up to 539 GeV or 600 GeV at 95% confidence level by the ATLAS or CMS experiments respectively. (author)

  11. Comparison BIPM.RI(I)-K8 of high dose-rate Ir-192 brachytherapy standards for reference air kerma rate of the VSL and the BIPM

    DEFF Research Database (Denmark)

    Alvarez, J.T.; De Pooter, J.A.; Andersen, Claus E.

    2014-01-01

    An indirect comparison of the standards for reference air kerma rate for 192Ir high dose rate brachytherapy sources of the Dutch Metrology Institute (VSL), The Netherlands, and of the Bureau International des Poids et Mesures (BIPM) was carried out at the VSL in November 2009. The comparison resu...

  12. [Studies on the identification of psychotropic substances. VIII. Preparation and various analytical data of reference standard of some stimulants, amfepramone, cathinone, N-ethylamphetamine, fenethylline, fenproporex and mefenorex].

    Science.gov (United States)

    Shimamine, M; Takahashi, K; Nakahara, Y

    1992-01-01

    The Reference Standards for amfepramone, cathinone, N-ethylamphetamine, fenethylline, fenproporex and mefenorex were prepared. Their purities determined by HPLC were more than 99.5%. For the identification and determination of these six drugs, their analytical data were measured and discussed by TLC, UV, IR, HPLC, GC/MS and NMR.

  13. Microwave-assisted versus conventional decomposition procedures applied to a ceramic potsherd standard reference material by inductively coupled plasma atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Papadopoulou, D.N.; Zachariadis, G.A.; Anthemidis, A.N.; Tsirliganis, N.C.; Stratis, J.A

    2004-03-03

    Inductively coupled plasma atomic emission spectrometry (ICP-AES) is a powerful, sensitive analytical technique with numerous applications in chemical characterization including that of ancient pottery, mainly due to its multi-element character, and the relatively short time required for the analysis. A critical step in characterization studies of ancient pottery is the selection of a suitable decomposition procedure for the ceramic matrix. The current work presents the results of a comparative study of six decomposition procedures applied on a standard ceramic potsherd reference material, SARM 69. The investigated decomposition procedures included three microwave-assisted decomposition procedures, one wet decomposition (WD) procedure by conventional heating, one combined microwave-assisted and conventional heating WD procedure, and one fusion procedure. Chemical analysis was carried out by ICP-AES. Five major (Si, Al, Fe, Ca, Mg), three minor (Mn, Ba, Ti) and two trace (Cu, Co) elements were determined and compared with their certified values. Quantitation was performed at two different spectral lines for each element and multi-element matrix-matched calibration standards were used. The recovery values for the six decomposition procedures ranged between 75 and 110% with a few notable exceptions. Data were processed statistically in order to evaluate the investigated decomposition procedures in terms of recovery, accuracy and precision, and eventually select the most appropriate one for ancient pottery analysis.

  14. A Novel Attempt to Standardize Results of CFD Simulations Basing on Spatial Configuration of Aortic Stent-Grafts.

    Directory of Open Access Journals (Sweden)

    Andrzej Polanczyk

    Full Text Available Currently, studies connected with Computational Fluid Dynamic (CFD techniques focus on assessing hemodynamic of blood flow in vessels in different conditions e.g. after stent-graft's placement. The paper propose a novel method of standardization of results obtained from calculations of stent-grafts' "pushing forces" (cumulative WSS--Wall Shear Stress, and describes its usefulness in diagnostic process. AngioCT data from 27 patients were used to reconstruct 3D geometries of stent-grafts which next were used to create respective reference cylinders. We made an assumption that both the side surface and the height of a stent-graft and a reference cylinder were equal. The proposed algorithm in conjunction with a stent-graft "pushing forces" on an implant wall, allowed us to determine which spatial configuration of a stent-graft predispose to the higher risk of its migration. For stent-grafts close to cylindrical shape (shape factor φ close to 1 WSS value was about 267 Pa, while for stent-grafts different from cylindrical shape (φ close to 2 WSS value was about 635 Pa. It was also noticed that deformation in the stent-graft's bifurcation part impaired blood flow hemodynamic. Concluding the proposed algorithm of standardization proved its usefulness in estimating the WSS values that may be useful in diagnostic process. Angular bends or tortuosity in bifurcations of an aortic implant should be considered in further studies of estimation of the risk of implantation failure.

  15. Common reference intervals for aspartate aminotransferase (AST), alanine aminotransferase (ALT) and γ-glutamyl transferase (GGT) in serum: results from an IFCC multicenter study.

    Science.gov (United States)

    Ceriotti, Ferruccio; Henny, Joseph; Queraltó, Josep; Ziyu, Shen; Özarda, Yeşim; Chen, Baorong; Boyd, James C; Panteghini, Mauro

    2010-11-01

    Aspartate aminotransferase (AST), alanine aminotransferase (ALT) and γ-glutamyl transferase (GGT) measurements are important for the assessment of liver damage. The aim of this study was to define the reference intervals (RIs) for these enzymes in adults, paying attention to standardization of the methods used and careful selection of the reference population. AST, ALT and GGT were measured with commercial analytical systems standardized to the IFCC-recommended reference measurement systems. Three centers (two in Italy and one in China) measured their own freshly collected samples; one of these centers also measured frozen samples from the Nordic Countries RI Project and from a Turkish center. RIs were generated using non-parametric techniques from the results of 765 individuals (411 females and 354 males, 18-85 years old) selected on the basis of the results of other laboratory tests and a specific questionnaire. AST results from the four regions (Milan, Beijing, Bursa and Nordic Countries) were statistically different, but these differences were too small to be clinically relevant. Likewise, differences between the upper reference limits for genders was only 1.7 U/L (0.03 μkat/L), allowing a single RI of 11-34 U/L (0.18-0.57 μkat/L) to be defined. Interregional differences were not statistically significant for ALT, but partitioning was required due to significant gender differences. RIs for ALT were 8-41 U/L (0.13-0.68 μkat/L) for females and 9-59 U/L (0.15-0.99 μkat/L) for males, respectively. The upper reference limits for GGT from the Nordic Country population were higher than those from the other three regions and results from this group were excluded from final calculations. The GGT RIs were 6-40 U/L (0.11-0.66 μkat/L) for females and 12-68 U/L (0.20- 1.13 μkat/L) for males, respectively. For AST and ALT, the implementation of common RIs appears to be possible, because no differences between regions were observed. However, a common RI for GGT that is

  16. Certification of total arsenic in blood and urine standard reference materials by radiochemical neutron activation analysis and inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    Paul, R.L.; Clay Davis, W.; Lee Yu; Murphy, K.E.; Bryan, C.E.; Vetter, T.W.; Guthrie, W.F.; Leber, D.D.; Gulchekhra Shakirova; Graylin Mitchell

    2014-01-01

    Radiochemical neutron activation analysis (RNAA) was used to measure arsenic at four levels in standard reference material (SRM) 955c Toxic Elements in Caprine Blood and at two levels in SRM 2668 Toxic Elements in Frozen Human Urine for the purpose of providing mass concentration values for certification. Samples were freeze-dried prior to analysis followed by neutron irradiation for 3 h at a fluence rate of 1 × 10 14 cm -2 s -1 . After sample dissolution in perchloric and nitric acids, arsenic was separated from the matrix either by retention on hydrated manganese dioxide (urine) or by extraction into zinc diethyldithiocarbamate in chloroform (blood). 76 As was quantified by gamma-ray spectroscopy. Differences in chemical yield and counting geometry between samples and standards were monitored by measuring the count rate of a 77 As tracer added before sample dissolution. RNAA results were combined with inductively coupled plasma-mass spectrometry values from National Institute of Standards and Technology and collaborating laboratories to provide certified values of 10.81 ± 0.54 and 213.1 ± 0.73 μg/L for SRM 2668 Levels I and II, and certified values of 21.66 ± 0.73, 52.7 ± 1.1, and 78.8 ± 4.9 μg/L for SRM 955c Levels II-IV, respectively. Because of discrepancies between values obtained by different methods for SRM 955c Level I, an information value of <5 μg/L was assigned for this material. (author)

  17. Quasi-reference electrodes in confined electrochemical cells can result in in situ production of metallic nanoparticles.

    Science.gov (United States)

    Perera, Rukshan T; Rosenstein, Jacob K

    2018-01-31

    Nanoscale working electrodes and miniaturized electroanalytical devices are valuable platforms to probe molecular phenomena and perform chemical analyses. However, the inherent close distance of metallic electrodes integrated into a small volume of electrolyte can complicate classical electroanalytical techniques. In this study, we use a scanning nanopipette contact probe as a model miniaturized electrochemical cell to demonstrate measurable side effects of the reaction occurring at a quasi-reference electrode. We provide evidence for in situ generation of nanoparticles in the absence of any electroactive species and we critically analyze the origin, nucleation, dissolution and dynamic behavior of these nanoparticles as they appear at the working electrode. It is crucial to recognize the implications of using quasi-reference electrodes in confined electrochemical cells, in order to accurately interpret the results of nanoscale electrochemical experiments.

  18. Standardized Test Results: KEEP and Control Students. 1975-1976, Technical Report #69.

    Science.gov (United States)

    Antill, Ellen; Speidel, Gisela E.

    This report presents the results of various standardized measures administered to Kamehameha Early Education Program (KEEP) students and control students in the school year 1975-1976. In contrast to previous comparisons, KEEP employed more rigorous procedures for the selection of the control students and for the conditions of test administration.…

  19. Anti-allergic activity of standardized extract of Albizia lebbeck with reference to catechin as a phytomarker.

    Science.gov (United States)

    Venkatesh, Pichairajan; Mukherjee, Pulok K; Kumar, Nanjappan Satheesh; Bandyopadhyay, Arun; Fukui, Hiroyuki; Mizuguchi, Hiroyuki; Islam, Nurul

    2010-06-01

    The major groups of phytonutrients found in plants include polyphenols, flavonoids, terpenes, amines, etc., all of which are observed to have potential anti-allergic activity. In this study, we evaluated the anti-allergic activity of the standardized extract of Albizia lebbeck with respect to the catechin, a polyphenolic phytomarker. The percentage of catechin in the ethanolic extract was found to be 14.72 mg/g. We administered Albizia lebbeck (50-300 mg/kg) and 50 mg/kg of catechin to mice to evaluate the mast cell stabilization and estimation of histamine elevation in the plasma. Results support the conclusion that Albizia lebbeck at different concentrations has got potent mast cell stabilizing property and the IC(50) value of Albizia lebbeck was found to be 85 microg/ml. This inhibitory potential of catechin from Albizia lebbeck is perhaps due to modulation of two important effector's functions, histamine release and cytokine expression of antigen -IgE activated mast cells.

  20. Battelle integrity of nuclear piping program. Summary of results and implications for codes/standards

    International Nuclear Information System (INIS)

    Miura, Naoki

    2005-01-01

    The BINP(Battelle Integrity of Nuclear Piping) program was proposed by Battelle to elaborate pipe fracture evaluation methods and to improve LBB and in-service flaw evaluation criteria. The program has been conducted from October 1998 to September 2003. In Japan, CRIEPI participated in the program on behalf of electric utilities and fabricators to catch up the technical backgrounds for possible future revision of LBB and in-service flaw evaluation standards and to investigate the issues needed to be reflected to current domestic standards. A series of the results obtained from the program has been well utilized for the new LBB Regulatory Guide Program by USNRC and for proposal of revised in-service flaw evaluation criteria to the ASME Code Committee. The results were assessed whether they had implications for the existing or future domestic standards. As a result, the impact of many of these issues, which were concerned to be adversely affected to LBB approval or allowable flaw sizes in flaw evaluation criteria, was found to be relatively minor under actual plant conditions. At the same time, some issues that needed to be resolved to address advanced and rational standards in the future were specified. (author)

  1. Non-destructive alpha-particle activation analysis of P, Cl, K and Ca in marine macro-alga samples using synthetic multielement reference material as comparative standard

    International Nuclear Information System (INIS)

    Iwata, Y.; Naitoh, H.; Suzuki, N.

    1992-01-01

    A Synthetic Reference Material (SyRM) composed with accurately known amounts of 12 elements has been prepared. The elemental composition of the SyRM is closely similar to that of marine macro-algae sample. The elemental composition of the SyRM was regulated by the starting materials used for the synthesis. The SyRM was used as a comparative standard for non-destructive alpha-particle activation analysis of marine macro-alga samples. P, Cl, K and Ca were determined simultaneously without correction for alpha range due to difference in the elemental composition between the analytical samples and the comparative standard. (author) 19 refs.; 4 tabs

  2. Non-SUSY Beyond Standard Model Searches: Recent Results from ATLAS and CMS

    International Nuclear Information System (INIS)

    Malek, Fairouz

    2015-01-01

    The Standard Model of particle physics is a sensational success, especially since the discovery of the 125 GeV Higgs boson. However, there are still numerous unanswered questions. Why is the Higgs so light? Do the interactions couplings unify and how can gravity be included? Why three fermion generations? What is dark matter? Theories Beyond the Standard Model (BSM), such as Grand Unified Theories, Extra Dimensions or Technicolour are trying to answer these questions. In these proceedings, we will focus on the most recent results obtained by the ATLAS and CMS experiments at the LHC for BSM searches, excluding Higgs and supersymmetry searches. New results on Dark Matter, heavy narrow-width resonances, new heavy quarks and third generation leptoquarks are presented. A summary of the prospects at 14 TeV and at the High Luminosity LHC period is given. (paper)

  3. Non-SUSY Beyond Standard Model Searches: Recent Results from ATLAS and CMS

    CERN Document Server

    Malek, Fairouz; The ATLAS collaboration

    2015-01-01

    The Standard Model of particle physics is a sensational success, especially since the discovery of the 125 GeV Higgs boson. However, there are still numerous unanswered questions. Why is the Higgs so light? Do the interactions couplings unify and how can gravity be included? Why three fermion generations? What is dark matter? Theories Beyond the Standard Model (BSM), such as Grand Unified Theories, Extra Dimensions or Technicolour are trying to answer these questions. In this proceedings, we will focus on the most recent results obtained by the ATLAS and CMS experiments at the LHC for BSM searches, excluding Higgs and supersymmetry searches. New results on Dark matter, heavy narrow bosons, new heavy quarks and third generation leptoquarks are presented. A summary of the prospects at 14 TeV and at the High Luminosity LHC period is given.

  4. Calibration and consistency of results of an ionization-chamber secondary standard measuring system for activity

    International Nuclear Information System (INIS)

    Schrader, Heinrich

    2000-01-01

    Calibration in terms of activity of the ionization-chamber secondary standard measuring systems at the PTB is described. The measurement results of a Centronic IG12/A20, a Vinten ISOCAL IV and a radionuclide calibrator chamber for nuclear medicine applications are discussed, their energy-dependent efficiency curves established and the consistency checked using recently evaluated radionuclide decay data. Criteria for evaluating and transferring calibration factors (or efficiencies) are given

  5. Evaluation of a draft standard on performance specifications for health physics instrumentation: results for environmental tests

    International Nuclear Information System (INIS)

    Kenoyer, J.L.; Swinth, K.L.; Mashburn, K.R.; Selby, J.M.

    1984-06-01

    Draft ANSI Standard N42.17 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. Evaluation is performed by testing a cross-section of currently available instruments with testing procedures based on specifications of the standard and then determining the degree of conformance to the various elements of the proposed standard. Data will be presented on the performance of a cross-section of beta-gamma survey instruments under various environmental tests. Test results that will be presented include temperature effects, humidity effects, radio frequency (r.f.) susceptibility, ambient pressure effects, vibration effects, and shock effects. Tests performed to date show that most instruments will meet the temperature, humidity, and ambient pressure tests. A large variability is noted among instruments from the same or different vendors. Preliminary r.f. susceptibility tests have shown large artificial responses at some frequencies for specific instruments. The presentation will also include a discussion of procedures used in the testing and weaknesses identified in the proposed standard

  6. Standard reference and other important nuclear data. Supplement 1 to the report BNL-NCS-51123 (Dec. 1979) = ENDF-300 = IAEA-NDS-15/300 (microfiche)

    Energy Technology Data Exchange (ETDEWEB)

    Bhat, M R [ed.

    1981-03-01

    The document contains inserts to be added to the report `Standard Reference and Other Important Nuclear Data` (BNL-NCS-51123, ENDF-300), including the following two articles: Fast Neutron Capture in {sup 238}U and {sup 232}Th by W.P. Poentiz (ANL), and {sup 239}Pu Decay Power Discrepancy by T.R. England and P.G. Young (LANL) Refs, figs

  7. Reporting the results of meta-analyses: a plea for incorporating clinical relevance referring to an example.

    Science.gov (United States)

    Bartels, Ronald H M A; Donk, Roland D; Verhagen, Wim I M; Hosman, Allard J F; Verbeek, André L M

    2017-11-01

    The results of meta-analyses are frequently reported, but understanding and interpreting them is difficult for both clinicians and patients. Statistical significances are presented without referring to values that imply clinical relevance. This study aimed to use the minimal clinically important difference (MCID) to rate the clinical relevance of a meta-analysis. This study is a review of the literature. This study is a review of meta-analyses relating to a specific topic, clinical results of cervical arthroplasty. The outcome measure used in the study was the MCID. We performed an extensive literature search of a series of meta-analyses evaluating a similar subject as an example. We searched in Pubmed and Embase through August 9, 2016, and found articles concerning meta-analyses of the clinical outcome of cervical arthroplasty compared with that of anterior cervical discectomy with fusion in cases of cervical degenerative disease. We evaluated the analyses for statistical significance and their relation to MCID. MCID was defined based on results in similar patient groups and a similar disease entity reported in the literature. We identified 21 meta-analyses, only one of which referred to MCID. However, the researchers used an inappropriate measurement scale and, therefore, an incorrect MCID. The majority of the conclusions were based on statistical results without mentioning clinical relevance. The majority of the articles we reviewed drew conclusions based on statistical differences instead of clinical relevance. We recommend introducing the concept of MCID while reporting the results of a meta-analysis, as well as mentioning the explicit scale of the analyzed measurement. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. A medical-legal review regarding the standard of care for epidural injections, with particular reference to a closed case.

    Science.gov (United States)

    Helm, Standiford; Glaser, Scott; Falco, Frank; Henry, Brian

    2010-01-01

    Interventional pain management is an evolving field, with a primary focus on the safety of the patient. One major source of risk to patients is intraarterial or intraneural injections. Interventional pain physicians have considerable interest in identifying techniques which avoid these complications. A recent article has reviewed complications associated with interventional procedures and concluded that the complications were due to deviation from a specific prescribed protocol. One of the cases reviewed went to jury trial and the record of that case is in the public domain. Two of the authors of the recent review were expert witnesses in the trial. They provided conflicting testimony as to alleged violations of the standard of care. Their criticisms also differed from a third criticism contained in the article as well as the protocol being advocated in the article, thus contravening the claim that there is one prescribed protocol which must be followed. The definition of standard of care varies amongst jurisdictions, but is generally defined as either that care which a reasonably well-trained physician in that specialty would provide under similar circumstances or as what would constitute reasonable medical care under the circumstances presented. Analysis of the case which went to trial indicates that there is not one prescribed protocol which must be followed; the definition of standard of care is broader than that. Interventional pain management is an evolving field and the standard of care is broadly defined.

  9. Reference dosimetry and small-field dosimetry in external beam radiotherapy: Results from a Danish intercomparison study

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg; Behrens, Claus F.; Sibolt, Patrik

    methods was performed by DTU Nutech at six Danish clinics. The first part of the intercompa-rison regarded the consistency of reference dosimetry. Absorbed dose to water under reference conditions was measured using a Farmer ionization chamber, and was found to agree within 1 % with the daily dose checks......-specific correction factors for non-reference fields....

  10. Renal Artery Stenosis Evaluated with 3D-Gd-Magnetic Resonance Angiography Using Transstenotic Pressure Gradient as the Standard of Reference. A Multireader Study

    International Nuclear Information System (INIS)

    Ekloef, H.; Ahlstrom, H.; Bostrom, A.; Bergqvist, D.; Andren, B.; Karacagil, S.; Nyman, R.

    2005-01-01

    Purpose: To evaluate 3D-Gd-magnetic resonance angiography (MRA) in detecting hemodynamically significant renal artery stenosis (RAS). Material and Methods: Thirty patients evaluated for atherosclerotic RAS by MRA and digital subtraction angiography (DSA) were retrospectively included. Standard of reference for hemodynamically significant RAS was a transstenotic gradient of 15 mmHg. DSA visualized 60 main renal arteries and 9 accessory arteries. Pressure gradient measurement (PGM) was available from 61 arteries. Three radiologists evaluated all examinations independently in a blinded fashion. Results: RAS was present in 26 arteries. On MRA, each reader identified 4 of 9 accessory renal arteries, a detection rate of 44%. The three readers correctly classified 22/25/22 of the 26 vessels with a significant gradient as >60% RAS and 31/25/32 of the 35 with a significant gradient as <60% RAS on MRA. Interobserver agreement was substantial. MRA image quality was adequate for RAS evaluations in all patients. ROC curves indicated that MRA is an adequate method for evaluating RAS. When screening for RAS, a 50% diameter reduction cut-off is better than 60%. RAS with 40-80% diameter reductions accounted for 65% of discrepancies. Conclusion: MRA is an adequate method for evaluating RAS limited mainly by poor detection rate for accessory renal arteries

  11. Evaluation of Outcome- Prenatal Diagnosis Indication and Results Suitability in Families Referred to our Laboratory For Prenatal Diagnosis

    Directory of Open Access Journals (Sweden)

    Ayşegül Türkyılmaz

    2007-01-01

    Full Text Available Since our aim is to establish the importance, necessity and concept of prenatal diagnosis in our region and supply routine service at a stage which we admit as a transitional period for application, all of the materials of amniocentesis, cordocentesis and corion villi sample referred to laboratories were evaluated without refusal.When we examined prenatal diagnoses of these specimens, we found Down Risk (according to triple test result in 164 specimens (%34, fetal anomaly risk in 122 (%25, advanced age in 69 (%14 poor-obstetric anamnesis in 27(%5, Down Syndrome- infant history in 20 (%4, family request in 17, and habitual abortus (%3 etc. in specimens. Lymphocyte Culture prepared in duplicate for each specimen and chromosome were obtained from total of ten slides for each specimen. Slides were stained with Giemsa Banding Technic (GTG Banding. Total (10x481 4810 slides were evaluated for diagnosis.There were no false positive and false negative results.

  12. Diferencias en las prevalencias de desnutrición al usarse referencias nacionales e internacionales Differences in the prevalence of malnutrition resulting from using a national growth reference or an international growth reference

    Directory of Open Access Journals (Sweden)

    Evelia Edith Oyhenart

    2005-09-01

    prevalencia de retraso del crecimiento.OBJECTIVE: To evaluate if using an international growth reference versus a national growth reference leads to differences in the prevalences of low weight-for-height (wasting and low height-for-age (stunting in a sample of children 8 to 14 years old. METHODS: A cross-sectional study was carried out with a sample of 1 470 school-children (both boys and girls in the city of La Plata, in the province of Buenos Aires, Argentina. Based on the data on weight and height, Z-scores were calculated with regard to the reference values from the United States of America's first and second National Health and Nutrition Examination Survey (NHANES I and NHANES II, and the reference values for Argentina from the Argentine Pediatric Society. The prevalences of wasting and stunting were calculated, using as the cutoff point two standard deviations below the median of the reference. The prevalences were compared using the chi-squared test with Yates' correction, and odds ratios (ORs and 95% confidence intervals (95% CIs were calculated. RESULTS: The international reference was positively associated with a higher prevalence of stunting in the entire sample (OR = 5.12; 95% CI: 3.27 to 8.05, in the boys (OR = 4.36; 95% CI: 2.43 to 7.93, and in the girls (OR = 6.32; 95% CI: 3.10 to 13.27. The prevalence of wasting was similar with both references. The distribution of height-for-age was skewed to the left with respect to the international reference and to the right with respect to the Argentine reference, while the distribution of weight-for-height overlapped both references. CONCLUSIONS: The differences in the prevalences of stunting calculated according to the two references that were used indicate a different nutritional status for the population studied. The increase in the height of the children with respect to the Argentine reference points to the presence of a positive secular trend, and the increase can explain part of the differences in the prevalence

  13. Accelerating the deployment of supply chain strategies through the adoption of standard operations reference model for supply chains producing capacity

    Energy Technology Data Exchange (ETDEWEB)

    Toews, A. [Project Plato Inc., Calgary, AB (Canada)

    2004-07-01

    This PowerPoint presentation provided information on how to build a procurement organization in the energy sector with reference to aligning supply chain management with corporate objectives to enhance response time in transactions with suppliers and customers. The paper examined the degree to which procurement functions are centralized versus decentralized and which combinations work best. It also examined how e-commerce can improve the efficiency and effectiveness of the procurement function and add value to an organization. The author emphasized the importance of a multi-functional team to create a successful sourcing strategy and develop strong purchasing capabilities within the organization. tabs., figs.

  14. Improving rehabilitation standards to meet changing community concerns: A history of uranium mine rehabilitation with particular reference to Northern Australia

    International Nuclear Information System (INIS)

    Waggitt, P.W.; Zapantis, A.

    2002-01-01

    Rehabilitation of land after mining is an issue that society has been wrestling with for at least 400 years. The issue is made even more emotive when the mineral extracted has been uranium. Over the past 50 years or so society has become ever more aware of the environment and the level of concern for proper environmental management has also increased. Today the community expects that mining in general, and uranium mining in particular, will be undertaken in an environmentally sensitive manner. As a consequence the expectations and standards for rehabilitation demanded by the community and regulators have been increasing and improving over time. Today the rehabilitation process is driven by issues of sustainable development, stakeholder involvement and consultation, inter-and intragenerational equity and a strong desire for environmental protection to be of the highest order. The paper describes this progressive improvement in rehabilitation standards using the uranium mines of northern Australia as case histories. (author)

  15. Stability results of a free air ionization chamber in standard mammography beams

    International Nuclear Information System (INIS)

    Silva, Natalia F.; Xavier, Marcos; Vivolo, Vitor; Caldas, Linda V.E.

    2015-01-01

    Free air ionization chambers are absolute dosimeters, because they can measure basic physical quantities directly without the need of their calibration in a standard radiation beam. They are used for measuring exposure and air kerma in X and gamma radiation beams. The Calibration Laboratory (LCI) of IPEN has a free air ionization chamber of the cylindrical type for low energies. The characterization of this ionization chamber was already performed and reported in a previous study. After a modification in the support of the micrometers used for the movement of the internal cylinder devices, the tests were redone. The objective of this work was to present the new alignment protocol of the free air ionization chamber in low energies of X-ray beams of standard mammography qualities, assuring the positioning reproducibility, and new results of stability tests performed with the application of this protocol will be presented. (author)

  16. Comparability of reference values

    International Nuclear Information System (INIS)

    Rossbach, M.; Stoeppler, M.

    1993-01-01

    Harmonization of certified values in Reference Materials (RMs) can be carried out by applying nuclear analytical techniques to RMs of various matrix types and concentration levels. Although RMs generally should not be used as primary standards the cross evaluation of concentrations in RMs leads to better compatibility of reference values and thus to a greater agreement between analytical results from different laboratories using these RMs for instrument calibration and quality assurance. (orig.)

  17. Differences in serum thyroglobulin measurements by 3 commercial immunoradiometric assay kits and laboratory standardization using Certified Reference Material 457 (CRM-457).

    Science.gov (United States)

    Lee, Ji In; Kim, Ji Young; Choi, Joon Young; Kim, Hee Kyung; Jang, Hye Won; Hur, Kyu Yeon; Kim, Jae Hyeon; Kim, Kwang-Won; Chung, Jae Hoon; Kim, Sun Wook

    2010-09-01

    Serum thyroglobulin (Tg) is essential in the follow-up of patients with differentiated thyroid carcinoma (DTC). However, interchangeability and standardization between Tg assays have not yet been achieved, even with the development of an international Tg standard (Certified Reference Material 457 [CRM-457]). Serum Tg from 30 DTC patients and serially diluted CRM-457 were measured using 3 different immunoradiometric assays (IRMA-1, IRMA-2, IRMA-3). The intraclass correlation coefficient (ICC) method was used to describe the concordance of each IRMA to CRM-457. The serum Tg measured by 3 different IRMAs correlated well (r > .85, p CRM-457, showed the best ICC (p(1) = .98) for the CRM-457. Hospitals caring for patients with DTC should either set their own cutoffs for IRMAs for Tg based on their patient pools, or adopt IRMAs standardized to CRM-457 and calibrate their laboratory using CRM-457.

  18. Quality assessment of Chrysanthemum indicum Flower by simultaneous quantification of six major ingredients using a single reference standard combined with HPLC fingerprint analysis

    Directory of Open Access Journals (Sweden)

    Jiao He

    2016-04-01

    Full Text Available Chrysanthemum indicum Flower is usually consumed as functional food. This paper described an improved total quality assessment method for Chrysanthemum indicum Flower by simultaneous quantitation using a single standard to determine multi-components method combined with high performance liquid chromatography fingerprint analysis. Six main components of Chrysanthemum indicum Flower including two flavonoids and four phenolic acids were simultaneously quantified using linarin as the internal reference standard. The method was fully validated with respect to linearity, precision, accuracy, robustness and stability. The validated method was successfully applied to the analysis of thirty three batches of Chrysanthemum indicum Flower samples. Under the same chromatographic conditions, fingerprint analysis in combination with Similarity analysis and principal component analysis was performed to identify the samples from different regions. In general, an effective assessment using a single standard to determinate multi-components method combined with fingerprint analysis make the reliable qualitation and quantitation analysis of Chrysanthemum indicum Flower available.

  19. Calibration comparative results for X - and gamma ray spectrometry with HPGe and BEGe detectors for a radon reference chamber

    International Nuclear Information System (INIS)

    Zoran, Maria; Paul, Annette; Arnold, Dirk

    2002-01-01

    Inhaled decay products of 222 Rn are the dominant components of the natural radiation exposure being responsible for about 30% of the whole human radioactive exposure. Field instruments for 222 Rn and his progeny monitoring are calibrated in 'radon climate rooms', where it is possible to vary and monitor 222 Rn and the indoor air parameters ( temperature, humidity, ventilation rate, aerosol concentration). German radon reference chamber used was developed and installed at the Physikalisch-Technische Bundesanstalt in order to serve as a metrological standard for radon and his progeny calibration of active and passive, indoor and outdoor radon monitoring devices in air climate. The basic parts of experimental setup for this γ and X -ray spectrometry analysis consists of a γ-X ray source in a lead shield/collimator, the detectors, the electronics necessary for pulse-height analysis (PHA) to obtain energy spectra. For calibrating system with 226 Ra standard sources (multienergy X ray and gamma emitters), two germanium detectors HPGe (12.5 nominal efficiency) and BEGe (22.5 nominal efficiency) were used. Germanium detectors are semiconductor diodes having a P-I-N structure in which the Intrinsic (I) region is sensitive to ionizing radiation, particularly X-rays and gamma rays. The BEGe is designed with an electrode structure that enhances low energy resolution and is fabricated from selected germanium having an impurity profile that improves charge collection (thus resolution and peak shape) at high energies which is really important in analysis of the complex spectra for uranium and finally for 226 Ra. MAESTRO MCA software and GNUPLOT program were used for spectra acquisition and spectra analysis, respectively . The main aim of this paper was to do a comparatively analysis of the detector performances for this radon chamber spectrometric chain. The calibration data analysis includes energy calibrations for both detection systems as well as comparative X and gamma

  20. Is It Working? Distractor Analysis Results from the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Stephanie

    2009-05-01

    The Test Of Astronomy STandards (TOAST) assessment instrument is a multiple-choice survey tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. Researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science and Math Teaching Center (UWYO SMTC) have been conducting a question-by-question distractor analysis procedure to determine the sensitivity and effectiveness of each item. In brief, the frequency each possible answer choice, known as a foil or distractor on a multiple-choice test, is determined and compared to the existing literature on the teaching and learning of astronomy. In addition to having statistical difficulty and discrimination values, a well functioning assessment item will show students selecting distractors in the relative proportions to how we expect them to respond based on known misconceptions and reasoning difficulties. In all cases, our distractor analysis suggests that all items are functioning as expected. These results add weight to the validity of the Test Of Astronomy STandards (TOAST) assessment instrument, which is designed to help instructors and researchers measure the impact of course-length duration instructional strategies for undergraduate science survey courses with learning goals tightly aligned to the consensus goals of the astronomy education community.

  1. Comparison of the permeability of metoprolol and labetalol in rat, mouse, and Caco-2 cells: use as a reference standard for BCS classification.

    Science.gov (United States)

    Incecayir, Tuba; Tsume, Yasuhiro; Amidon, Gordon L

    2013-03-04

    The purpose of this study was to investigate labetalol as a potential high permeability reference standard for the application of Biopharmaceutics Classification Systems (BCS). Permeabilities of labetalol and metoprolol were investigated in animal intestinal perfusion models and Caco-2 cell monolayers. After isolating specific intestinal segments, in situ single-pass intestinal perfusions (SPIP) were performed in rats and mice. The effective permeabilities (Peff) of labetalol and metoprolol, an FDA standard for the low/high Peff class boundary, were investigated in two different segments of rat intestine (proximal jejunum and distal ileum) and in the proximal jejunum of mouse. No significant difference was found between Peff of metoprolol and labetalol in the jejunum and ileum of rat (0.33 ± 0.11 × 10(-4) vs 0.38 ± 0.06 × 10(-4) and 0.57 ± 0.17 × 10(-4) vs 0.64 ± 0.30 × 10(-4) cm/s, respectively) and in the jejunum of mouse (0.55 ± 0.05 × 10(-4) vs 0.59 ± 0.13 × 10(-4) cm/s). However, Peff of metoprolol and labetalol were 1.7 and 1.6 times higher in the jejunum of mouse, compared to the jejunum of rat, respectively. Metoprolol and labetalol showed segmental-dependent permeability through the rat intestine, with increased Peff in the distal ileum in comparison to the proximal jejunum. Most significantly, Peff of labetalol was found to be concentration-dependent. Decreasing concentrations of labetalol in the perfusate resulted in decreased Peff compared to Peff of metoprolol. The intestinal epithelial permeability of labetalol was lower than that of metoprolol in Caco-2 cells at both apical pH 6.5 and 7.5 (5.96 ± 1.96 × 10(-6) vs 9.44 ± 3.44 × 10(-6) and 15.9 ± 2.2 × 10(-6) vs 23.2 ± 7.1 × 10(-6) cm/s, respectively). Labetalol exhibited higher permeability in basolateral to apical (BL-AP) compared to AP-BL direction in Caco-2 cells at 0.1 times the highest dose strength (HDS) (46.7 ± 6.5 × 10(-6) vs 14.2 ± 1.5 × 10(-6) cm/s). The P

  2. Fluorescence optical imaging and 3T-MRI for detection of synovitis in patients with rheumatoid arthritis in comparison to a composite standard of reference.

    Science.gov (United States)

    Thuermel, Klaus; Neumann, Jan; Jungmann, Pia M; Schäffeler, Christoph; Waldt, Simone; Heinze, Alexander; Beckmann, Alexander; Hauser, Christine; Hasenau, Anna-Lena; Wildgruber, Moritz; Clotten, Sigrun; Sievert, Matti; Haller, Bernhard; Woertler, Klaus; Harasser, Norbert; Rummeny, Ernst J; Meier, Reinhard

    2017-05-01

    To address whether Indocyanine Green (ICG) enhanced fluorescence optical imaging (FOI) is more sensitive than magnetic resonance imaging (MRI) in the detection of synovitis of the wrist and finger joints in rheumatoid arthritis and to analyze the performance of FOI depending on the grade of synovitis. Twenty patients with highly active rheumatoid arthritis (mean DAS28-ESR 5.25±1.0) and thirteen healthy volunteers underwent clinical examination, FOI and contrast-enhanced 3T-MRI. Joints were rated by three independent readers semiquantitatively (grade 0-3: no, low, moderate and high grade synovitis) and compared to a semiquantitative composite standard of reference (cSOR, grade 0-3) that incorporated clinical parameters, FOI and MRI results. 2.868 evaluations in 956 joints were performed. FOI had an overall sensitivity of 57.3% and a specificity of 92.1%, whereas MRI had a sensitivity of 89.2% and a specificity of 92.6%. The sensitivity of FOI increased with the degree of synovitis to 65.0% for moderate and severe synovitis (specificity 88.1%) and 76,3% for severe synovitis (specificity 80.5%). The performance of FOI decreased with the degree of synovitis with false negative results predominantly for mild (156/343, 45.5%) and moderate (160/343, 46.6%) synovitis and false positive FOI evaluations predominantly based on weak (grade 1) signals (133/163, 81,6%). FOI has a lower sensitivity than 3T-MRI in the detection of synovitis of the hand and finger joints. The diagnostic performance of FOI decreases with the degree of synovitis and with the strength of FOI signals. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Frequency of Eyelid Malpositions and their Treatment Results in Patients Referred to Ophthalmology Clinics in Educational Yazd Hospitals

    Directory of Open Access Journals (Sweden)

    M Rafieian

    2012-10-01

    Full Text Available Introduction: Entropion and ectropion with involutional changes are the most common eyelid malpositions. Entropion is a condition in which the eyelid margin turns inwards against the globe and ectropion is a malposition in which the lid turns outwards or is pulled away its normal position from the globe. Knowledge of eyelid problems and their abnormalities is a key to plan a successful surgical procedure. Methods: This descriptive study lasted from Sep. 2008 to March 2009. We evaluated 78 patients with eyelid malpositions who referred to educational hospitals of Yazd. The patients were examined by an eye specialist. Each patient’s demographic data, type of eyelid malposition, specific treatment results and 6-month follow up of each patient were recorded by the questioners and then were analyzed statistically by SPSS13 software, chi-square and fisher exact test. Results: Among 78 cases, entropion was observed in 41 cases(52.6%, trichiasis in 31 cases(39.7%, ectropion in 27 cases(34.6% and distichiasis in 3 cases (3.8%. The Wies procedure proved to be influential in entropion treatment and lateral tarsal strip canthoplasty surgery also reported acceptable results in ectropion. Conclusion: The involutional changes were the most common causing factors for eyelid malpositions. Entropion appears most prevalently specially in right upper eyelid. The Wies and lateral tarsal strip canthoplasty procedures were thoroughly successful in treatment of entropion and ectropion of either upper or lower eyelids

  4. Claims about Medical Malpractices Resulting in Maternal and Perinatal Mortality Referred to Iranian Legal Medicine Organization During 2011–2012

    Science.gov (United States)

    Taghizadeh, Ziba; Pourbakhtiar, Maryam; Ghadipasha, Masoud; Soltani, Kamran; Azimi, Khadijeh

    2017-01-01

    Background: Obstetricians, gynecologists, and midwives are the most common specialists of the medical sciences group against whom medical malpractices are claimed, many of which are avoidable and preventable. Therefore, the present study was conducted to investigate the causes of claims regarding medical malpractices resulting in maternal and perinatal mortality. Materials and Methods: A descriptive cross-sectional study was conducted and 7616 claims of medical malpractices in the field of obstetrics, gynecology, and midwifery that were referred from all 31 provinces to the central commission of legal medicine were studied during 2011–2012. Therefore, the present research is a national inclusive study covering all the provinces across Iran. To collect information from the transcript of medical malpractices cases, a researcher-made checklist was used, and the collected data were analyzed. Results: The results of the present study showed that among all the medical malpractice claims regarding pregnancy and childbirth (42.24%), the majority concerned perinatal death (71.82%) and maternal death (28.16%). Conclusions: Medical malpractice complaints are increasing; although, most of these claims are preventable. To achieve this aim, it is necessary for obstetricians, gynecologists, and midwives to try to reduce the complaints by paying more attention to the signs and symptoms of diseases, performing all the diagnostic and therapeutic measures according to the scientific criteria, and fully document patients' records. In addition, patients' acquaintance with the importance of measurements and examinations, before and during pregnancy care and even after childbirth is crucial. PMID:28904542

  5. Using Florida Keys Reference Sites As a Standard for Restoration of Forest Structure in Everglades Tree Islands

    International Nuclear Information System (INIS)

    Ross, M.S.; Sah, J.P.; Ruiz, P.L.; Ross, M.S.; Ogurcak, D.E.

    2010-01-01

    In south Florida, tropical hardwood forests (hammocks) occur in Everglades tree islands and as more extensive forests in coastal settings in the nearby Florida Keys. Keys hammocks have been less disturbed by humans, and many qualify as old-growth, while Everglades hammocks have received much heavier use. With improvement of tree island condition an important element in Everglades restoration efforts, we examined stand structure in 23 Keys hammocks and 69 Everglades tree islands. Based on Stand Density Index and tree diameter distributions, many Everglades hammocks were characterized by low stocking and under-representation in the smaller size classes. In contrast, most Keys forests had the dense canopies and open under stories usually associated with old-growth hardwood hammocks. Subject to the same caveats that apply to off-site references elsewhere, structural information from mature Keys hammocks can be helpful in planning and implementing forest restoration in Everglades tree islands. In many of these islands, such restoration might involve supplementing tree stocking by planting native trees to produce more complete site utilization and a more open under story.

  6. High accuracy determination of trace elements in NIST standard reference materials by isotope dilution ICP-MS

    International Nuclear Information System (INIS)

    Paulsen, P.J.; Beary, E.S.

    1996-01-01

    At NIST (National Institute of Standards and Technology), ICP-MS ID (inductively coupled mass spectrometry isotope dilution) has been used to certify a wide range of elements in a variety of materials with high accuracy. Both the chemical preparation and instrumental procedures are simpler than with other ID mass spectrometric techniques. The ICP-MS has picogram/ml detection limits for most elements using fixed operating parameters. Chemical separations are required only to remove an interference (from molecular ions as well as isobaric atoms), or to pre-concentrate the analyte. For example, chemical separations were required for the analysis of SRM 2711, Montana II Soil, but not for boron in peach leaves, SRM 1547.(3 refs., 3 tabs., 2 figs

  7. Recent Result from E821 Experiment on Muon g-2 and Unconstrained Minimal Supersymemtric Standard Model

    CERN Document Server

    Komine, S; Yamaguchi, M; Komine, Shinji; Moroi, Takeo; Yamaguchi, Masahiro

    2001-01-01

    Recently, the E821 experiment at the Brookhaven National Laboratory announced their latest result of their muon g-2 measurement which is about 2.6-\\sigma away from the standard model prediction. Taking this result seriously, we examine the possibility to explain this discrepancy by the supersymmetric contribution. Our analysis is performed in the framework of the unconstrained supersymmetric standard model which has free seven parameters relevant to muon g-2. We found that, in the case of large \\tan\\beta, sparticle masses are allowed to be large in the region where the SUSY contribution to the muon g-2 is large enough, and hence the conventional SUSY search may fail even at the LHC. On the contrary, to explain the discrepancy in the case of small \\tan\\beta, we found that (i) sleptons and SU(2)_L gauginos should be light, and (ii) negative search for the Higgs boson severely constrains the model in the framework of the mSUGRA and gauge-mediated model.

  8. In-situ calibration of clinical built-in KAP meters with traceability to a primary standard using a reference KAP meter.

    Science.gov (United States)

    Malusek, A; Helmrot, E; Sandborg, M; Grindborg, J-E; Carlsson, G Alm

    2014-12-07

    The air kerma-area product (KAP) is used for settings of diagnostic reference levels. The International Atomic Energy Agency (IAEA) recommends that doses in diagnostic radiology (including the KAP values) be estimated with an accuracy of at least ± 7% (k = 2). Industry standards defined by the International Electrotechnical Commission (IEC) specify that the uncertainty of KAP meter measurements should be less than ± 25% (k = 2). Medical physicists willing to comply with the IAEA's recommendation need to apply correction factors to KAP values reported by x-ray units. The aim of this work is to present and evaluate a calibration method for built-in KAP meters on clinical x-ray units. The method is based on (i) a tandem calibration method, which uses a reference KAP meter calibrated to measure the incident radiation, (ii) measurements using an energy-independent ionization chamber to correct for the energy dependence of the reference KAP meter, and (iii) Monte Carlo simulations of the beam quality correction factors that correct for differences between beam qualities at a standard laboratory and the clinic. The method was applied to the KAP meter in a Siemens Aristos FX plus unit. It was found that values reported by the built-in KAP meter differed from the more accurate values measured by the reference KAP meter by more than 25% for high tube voltages (more than 140 kV) and heavily filtered beams (0.3 mm Cu). Associated uncertainties were too high to claim that the IEC's limit of 25% was exceeded. Nevertheless the differences were high enough to justify the need for a more accurate calibration of built-in KAP meters.

  9. Agreement between gastrointestinal panel testing and standard microbiology methods for detecting pathogens in suspected infectious gastroenteritis: Test evaluation and meta-analysis in the absence of a reference standard.

    Science.gov (United States)

    Freeman, Karoline; Tsertsvadze, Alexander; Taylor-Phillips, Sian; McCarthy, Noel; Mistry, Hema; Manuel, Rohini; Mason, James

    2017-01-01

    Multiplex gastrointestinal pathogen panel (GPP) tests simultaneously identify bacterial, viral and parasitic pathogens from the stool samples of patients with suspected infectious gastroenteritis presenting in hospital or the community. We undertook a systematic review to compare the accuracy of GPP tests with standard microbiology techniques. Searches in Medline, Embase, Web of Science and the Cochrane library were undertaken from inception to January 2016. Eligible studies compared GPP tests with standard microbiology techniques in patients with suspected gastroenteritis. Quality assessment of included studies used tailored QUADAS-2. In the absence of a reference standard we analysed test performance taking GPP tests and standard microbiology techniques in turn as the benchmark test, using random effects meta-analysis of proportions. No study provided an adequate reference standard with which to compare the test accuracy of GPP and conventional tests. Ten studies informed a meta-analysis of positive and negative agreement. Positive agreement across all pathogens was 0.93 (95% CI 0.90 to 0.96) when conventional methods were the benchmark and 0.68 (95% CI: 0.58 to 0.77) when GPP provided the benchmark. Negative agreement was high in both instances due to the high proportion of negative cases. GPP testing produced a greater number of pathogen-positive findings than conventional testing. It is unclear whether these additional 'positives' are clinically important. GPP testing has the potential to simplify testing and accelerate reporting when compared to conventional microbiology methods. However the impact of GPP testing upon the management, treatment and outcome of patients is poorly understood and further studies are needed to evaluate the health economic impact of GPP testing compared with standard methods. The review protocol is registered with PROSPERO as CRD42016033320.

  10. NBS SRM 1569 Brewer's Yeast: Is it an adequate standard reference material for testing a chromium determination in biological materials tion in biological materials

    International Nuclear Information System (INIS)

    Goeij, J.J.M. de; Volkers, K.J.; Tjioe, P.S.; Kroon, J.J.

    1978-01-01

    Some analytical experiences with NBS SRM 1569 Brewer's Yeast are presented. Against this background the adequacy of this standard reference material for the determination of chromium in biological materials is discussed. Authors have three main objections. Due to its high content of insoluble chromium-containing particles, SRM 1569 is not typical for biological materials, possibly not even for Brewer's Yeast. The chromium level of SRM 1569 is not typical for the chromium levels normally encountered in pure biological materials. The major fraction (69 +- 3 percent) of the chromium is present in a form which is insoluble under the conditions used in Author's analysis. (T.I.)

  11. HYGIEN AND TECHNOLOGY OF SMOKED SALMON’S PRODUCTION: COMPARISON BETWEEN STANDARD HEALTLY REFERENCE OF EUROPEAN LEGISLATION AND AN EXTRACOMUNITY ONE

    Directory of Open Access Journals (Sweden)

    E.M. Mannocchi

    2013-02-01

    Full Text Available The work makes a comparison between European and Switzerland legislation through an inspection in an artisan producing smoked salmon factory. The analysis of HACCP plan, technology and microbiological characteristic of finished product, as enshrined in Switzerland law, allow to categorize the business risk level respect the European reference. The criticalities detected are: Listeria monocytogenes and Anisakis spp.. A plain was developed for improving the hygienic characteristic of the production to ensure the alignment of structure to the standards specified by the European requirements and allow to the factory send his products inside the European market.

  12. dcmqi: An Open Source Library for Standardized Communication of Quantitative Image Analysis Results Using DICOM.

    Science.gov (United States)

    Herz, Christian; Fillion-Robin, Jean-Christophe; Onken, Michael; Riesmeier, Jörg; Lasso, Andras; Pinter, Csaba; Fichtinger, Gabor; Pieper, Steve; Clunie, David; Kikinis, Ron; Fedorov, Andriy

    2017-11-01

    Quantitative analysis of clinical image data is an active area of research that holds promise for precision medicine, early assessment of treatment response, and objective characterization of the disease. Interoperability, data sharing, and the ability to mine the resulting data are of increasing importance, given the explosive growth in the number of quantitative analysis methods being proposed. The Digital Imaging and Communications in Medicine (DICOM) standard is widely adopted for image and metadata in radiology. dcmqi (DICOM for Quantitative Imaging) is a free, open source library that implements conversion of the data stored in commonly used research formats into the standard DICOM representation. dcmqi source code is distributed under BSD-style license. It is freely available as a precompiled binary package for every major operating system, as a Docker image, and as an extension to 3D Slicer. Installation and usage instructions are provided in the GitHub repository at https://github.com/qiicr/dcmqi Cancer Res; 77(21); e87-90. ©2017 AACR . ©2017 American Association for Cancer Research.

  13. An XML standard for the dissemination of annotated 2D gel electrophoresis data complemented with mass spectrometry results

    Directory of Open Access Journals (Sweden)

    Arthur John

    2004-01-01

    Full Text Available Abstract Background Many proteomics initiatives require a seamless bioinformatics integration of a range of analytical steps between sample collection and systems modeling immediately assessable to the participants involved in the process. Proteomics profiling by 2D gel electrophoresis to the putative identification of differentially expressed proteins by comparison of mass spectrometry results with reference databases, includes many components of sample processing, not just analysis and interpretation, are regularly revisited and updated. In order for such updates and dissemination of data, a suitable data structure is needed. However, there are no such data structures currently available for the storing of data for multiple gels generated through a single proteomic experiments in a single XML file. This paper proposes a data structure based on XML standards to fill the void that exists between data generated by proteomics experiments and storing of data. Results In order to address the resulting procedural fluidity we have adopted and implemented a data model centered on the concept of annotated gel (AG as the format for delivery and management of 2D Gel electrophoresis results. An eXtensible Markup Language (XML schema is proposed to manage, analyze and disseminate annotated 2D Gel electrophoresis results. The structure of AG objects is formally represented using XML, resulting in the definition of the AGML syntax presented here. Conclusion The proposed schema accommodates data on the electrophoresis results as well as the mass-spectrometry analysis of selected gel spots. A web-based software library is being developed to handle data storage, analysis and graphic representation. Computational tools described will be made available at http://bioinformatics.musc.edu/agml. Our development of AGML provides a simple data structure for storing 2D gel electrophoresis data.

  14. Instant standard concept for data standards development

    NARCIS (Netherlands)

    Folmer, Erwin Johan Albert; Kulcsor, Istvan Zsolt; Roes, Jasper

    2013-01-01

    This paper presents the current results of an ongoing research about a new data standards development concept. The concept is called Instant Standard referring to the pressure that is generated by shrinking the length of the standardization process. Based on this concept it is estimated that the

  15. [Influenza surveillance in nine consecutive seasons, 2003-2012: results from National Influenza Reference Laboratory, Istanbul Faculty Of Medicine, Turkey].

    Science.gov (United States)

    Akçay Ciblak, Meral; Kanturvardar Tütenyurd, Melis; Asar, Serkan; Tulunoğlu, Merve; Fındıkçı, Nurcihan; Badur, Selim

    2012-10-01

    Influenza is a public health problem that affects 5-20% of the world population annually causing high morbidity and mortality especially in risk groups. In addition to determining prevention and treatment strategies with vaccines and antivirals, surveillance data plays an important role in combat against influenza. Surveillance provides valuable data on characteristics of influenza activity, on types, sub-types, antigenic properties and antiviral resistance profile of circulating viruses in a given region. The first influenza surveillance was initiated as a pilot study in 2003 by now named National Influenza Reference Laboratory, Istanbul Faculty of Medicine. Surveillance was launched at national level by Ministry of Health in 2004 and two National Influenza Laboratories, one in Istanbul and the other in Ankara, have been conducting surveillance in Turkey. Surveillance data obtained for nine consecutive years, 2003-2012, by National Influenza Reference Laboratory in Istanbul Faculty of Medicine have been summarized in this report. During 2003-2012 influenza surveillance seasons, a total of 11.077 nasal swabs collected in viral transport medium were sent to the National Influenza Reference Laboratory, Istanbul for analysis. Immun-capture ELISA followed by MDCK cell culture was used for detection of influenza viruses before 2009 and real-time RT-PCR was used thereafter. Antigenic characterizations were done by hemagglutination inhibition assay with the reactives supplied by World Health Organization. Analysis of the results showed that influenza B viruses have entered the circulation in 2005-2006 seasons, and have contributed to the epidemics at increasing rates every year except in the 2009 pandemic season. Influenza B Victoria and Yamagata lineages were cocirculating for two seasons. For other seasons either lineage was in circulation. Antigenic characterization revealed that circulating B viruses matched the vaccine composition either partially or totally for only

  16. Inelastic dark matter, non-standard halos and the DAMA/LIBRA results

    International Nuclear Information System (INIS)

    March-Russell, John; McCabe, Christopher; McCullough, Matthew

    2009-01-01

    The DAMA collaboration have claimed to detect particle dark matter (DM) via an annual modulation in their observed recoil event rate. This appears to be in strong disagreement with the null results of other experiments if interpreted in terms of elastic DM scattering, while agreement for a small region of parameter space is possible for inelastic DM (iDM) due to the altered kinematics of the collision. To date most analyses assume a simple galactic halo DM velocity distribution, the Standard Halo Model, but direct experimental support for the SHM is severely lacking and theoretical studies indicate possible significant differences. We investigate the dependence of DAMA and the other direct detection experiments on the local DM velocity distribution, utilizing the results of the Via Lactea and Dark Disc numerical simulations. We also investigate effects of varying the solar circular velocity, the DM escape velocity, and the DAMA quenching factor within experimental limits. Our data set includes the latest ZEPLIN-III results, as well as full publicly available data sets. Due to the more sensitive dependence of the inelastic cross section on the velocity distribution, we find that with Via Lactea the DAMA results can be consistent with all other experiments over an enlarged region of iDM parameter space, with higher mass particles being preferred, while Dark Disc does not lead to an improvement. A definitive test of DAMA for iDM requires heavy element detectors.

  17. Converting Differential Photometry Results to the Standard System using Transform Generator and Transform Applier (Abstract)

    Science.gov (United States)

    Ciocca, M.

    2016-12-01

    (Abstract only) Since Fall of 2014, AAVSO made available two very useful software tools: transform generator (tg) and transform applier (ta). tg, authored by Gordon Myers (gordonmyers@hotmail.com), is a program, running under python that allows the user to obtain the transformation coefficients of their imaging train. ta, authored by George Silvis, allows users to apply the transformation coefficients obtained previously to their photometric observation. The data so processed become then directly comparable to those of other observers. I will show how to obtain transform coefficient using two Standard Field (M 67 and NGC7790), how consistent the results are and as an application, I will present transformed data for two AAVSO Target stars, AE UMA and RR CET.

  18. The MCCB impairment profile for schizophrenia outpatients: results from the MATRICS psychometric and standardization study.

    Science.gov (United States)

    Kern, Robert S; Gold, James M; Dickinson, Dwight; Green, Michael F; Nuechterlein, Keith H; Baade, Lyle E; Keefe, Richard S E; Mesholam-Gately, Raquelle I; Seidman, Larry J; Lee, Cathy; Sugar, Catherine A; Marder, Stephen R

    2011-03-01

    The MATRICS Psychometric and Standardization Study was conducted as a final stage in the development of the MATRICS Consensus Cognitive Battery (MCCB). The study included 176 persons with schizophrenia or schizoaffective disorder and 300 community residents. Data were analyzed to examine the cognitive profile of clinically stable schizophrenia patients on the MCCB. Secondarily, the data were analyzed to identify which combination of cognitive domains and corresponding cut-off scores best discriminated patients from community residents, and patients competitively employed vs. those not. Raw scores on the ten MCCB tests were entered into the MCCB scoring program which provided age- and gender-corrected T-scores on seven cognitive domains. To test for between-group differences, we conducted a 2 (group)×7 (cognitive domain) MANOVA with follow-up independent t-tests on the individual domains. Classification and regression trees (CART) were used for the discrimination analyses. Examination of patient T-scores across the seven cognitive domains revealed a relatively compact profile with T-scores ranging from 33.4 for speed of processing to 39.3 for reasoning and problem-solving. Speed of processing and social cognition best distinguished individuals with schizophrenia from community residents; speed of processing along with visual learning and attention/vigilance optimally distinguished patients competitively employed from those who were not. The cognitive profile findings provide a standard to which future studies can compare results from other schizophrenia samples and related disorders; the classification results point to specific areas and levels of cognitive impairment that may advance work rehabilitation efforts. Published by Elsevier B.V.

  19. An XML standard for the dissemination of annotated 2D gel electrophoresis data complemented with mass spectrometry results.

    Science.gov (United States)

    Stanislaus, Romesh; Jiang, Liu Hong; Swartz, Martha; Arthur, John; Almeida, Jonas S

    2004-01-29

    Many proteomics initiatives require a seamless bioinformatics integration of a range of analytical steps between sample collection and systems modeling immediately assessable to the participants involved in the process. Proteomics profiling by 2D gel electrophoresis to the putative identification of differentially expressed proteins by comparison of mass spectrometry results with reference databases, includes many components of sample processing, not just analysis and interpretation, are regularly revisited and updated. In order for such updates and dissemination of data, a suitable data structure is needed. However, there are no such data structures currently available for the storing of data for multiple gels generated through a single proteomic experiments in a single XML file. This paper proposes a data structure based on XML standards to fill the void that exists between data generated by proteomics experiments and storing of data. In order to address the resulting procedural fluidity we have adopted and implemented a data model centered on the concept of annotated gel (AG) as the format for delivery and management of 2D Gel electrophoresis results. An eXtensible Markup Language (XML) schema is proposed to manage, analyze and disseminate annotated 2D Gel electrophoresis results. The structure of AG objects is formally represented using XML, resulting in the definition of the AGML syntax presented here. The proposed schema accommodates data on the electrophoresis results as well as the mass-spectrometry analysis of selected gel spots. A web-based software library is being developed to handle data storage, analysis and graphic representation. Computational tools described will be made available at http://bioinformatics.musc.edu/agml. Our development of AGML provides a simple data structure for storing 2D gel electrophoresis data.

  20. The synthesis and certification of zirconia certified reference materials (CRM) as a processed result of zircon sand

    International Nuclear Information System (INIS)

    Samin; Supriyanto C; Sajima

    2016-01-01

    In order to support the pilot plant of zirconia production at PSTA-BATAN, synthesis and certification of zirconia certified reference materials (CRM) is absolutely needed. The synthesis and certification of zirconia CRM has been carried out from the row material of zirconium oxide chloride as a processed result of Kalimantan zircon sand. Zirconium oxide chloride dissolved in distilled water (1:10), added by ammonia at pH 10, it was formed a zirconium hydroxide precipitate. Zirconium hydroxide was heated at 110 °C and calcination at a temperature of 900 °C in order to obtain zirconia. Zirconia was dried at 110 °C, crushed and sieved to obtain a grain size of 200 mesh qualify. Zirconia powder was homogenized and then treated by homogenation test, stabilization test, characterization test and water content test. In the evaluation of the test data showed that candidate of CRM zirconia were homogeneous, stable, contain the monoklin of baddeleyite minerals and the water content obtained was less than 1%. It was concluded that zirconia powder are already physical qualified as CRM. Certificate of test results on parameters of zirconia CRM from 7 accredited laboratories using statistical methods obtained 9 oxides were ZrO_2 : (95.422 ± 0.027)%; HfO_2: (1.443 ± 0.004)%; SiO_2 : (0.535 ± 0.002)%; Al_2O_3 : (0.362 ± 0.012)%; Fe_2O_3 : (0.028 ± 0.003)%; TiO_2: (0.026 ± 0.001) %; Na_2O: (0.262 ± 0.026)%; Nd_2O_3 : (0.0367 ± 0.007)%; CeO_2: (0.131 ± 0.013)%. This certification was traceable to BCS-CRM No. 358 zirconia from BAS-France. (author)

  1. The evaluation of accuracy of NAA method used by P2TRR laboratory with food standard reference material analysis

    International Nuclear Information System (INIS)

    Rina M, Th.; Sri-Wardhani; Sunarko

    2003-01-01

    The NAA method is the analysis method with high precision and accuracy level. The precision and accuracy of NAA laboratory in P2TRR had been evaluated with SRM 1573a Tomato Leaf and CRM No.9 Sargasso. Samples were irradiated in RSG-GAS's rabbit system and counted with gamma spectrometry. The results obtained from this research are for the SRM 1573a sample the test could analyze 17 elements of the 40 certified elements, and for CRM No.9 sample the test could analyze 16 elements of the 30 certified elements. The result of quantitative analysis indicate the different deviation of each element between 2 -10.5 % compared to the certificate data. This deviation value <15%, this value shows that the precision and accuracy level is good enough

  2. A novel strategy with standardized reference extract qualification and single compound quantitative evaluation for quality control of Panax notoginseng used as a functional food.

    Science.gov (United States)

    Li, S P; Qiao, C F; Chen, Y W; Zhao, J; Cui, X M; Zhang, Q W; Liu, X M; Hu, D J

    2013-10-25

    Root of Panax notoginseng (Burk.) F.H. Chen (Sanqi in Chinese) is one of traditional Chinese medicines (TCMs) based functional food. Saponins are the major bioactive components. The shortage of reference compounds or chemical standards is one of the main bottlenecks for quality control of TCMs. A novel strategy, i.e. standardized reference extract based qualification and single calibrated components directly quantitative estimation of multiple analytes, was proposed to easily and effectively control the quality of natural functional foods such as Sanqi. The feasibility and credibility of this methodology were also assessed with a developed fast HPLC method. Five saponins, including ginsenoside Rg1, Re, Rb1, Rd and notoginsenoside R1 were rapidly separated using a conventional HPLC in 20 min. The quantification method was also compared with individual calibration curve method. The strategy is feasible and credible, which is easily and effectively adapted for improving the quality control of natural functional foods such as Sanqi. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Revision of the SNPforID 34-plex forensic ancestry test: Assay enhancements, standard reference sample genotypes and extended population studies.

    Science.gov (United States)

    Fondevila, M; Phillips, C; Santos, C; Freire Aradas, A; Vallone, P M; Butler, J M; Lareu, M V; Carracedo, A

    2013-01-01

    A revision of an established 34 SNP forensic ancestry test has been made by swapping the under-performing rs727811 component SNP with the highly informative rs3827760 that shows a near-fixed East Asian specific allele. We collated SNP variability data for the revised SNP set in 66 reference populations from 1000 Genomes and HGDP-CEPH panels and used this as reference data to analyse four U.S. populations showing a range of admixture patterns. The U.S. Hispanics sample in particular displayed heterogeneous values of co-ancestry between European, Native American and African contributors, likely to reflect in part, the way this disparate group is defined using cultural as well as population genetic parameters. The genotyping of over 700 U.S. population samples also provided the opportunity to thoroughly gauge peak mobility variation and peak height ratios observed from routine use of the single base extension chemistry of the 34-plex test. Finally, the genotyping of the widely used DNA profiling Standard Reference Material samples plus other control DNAs completes the audit of the 34-plex assay to allow forensic practitioners to apply this test more readily in their own laboratories. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  4. High-resolution global grids of revised Priestley-Taylor and Hargreaves-Samani coefficients for assessing ASCE-standardized reference crop evapotranspiration and solar radiation

    Science.gov (United States)

    Aschonitis, Vassilis G.; Papamichail, Dimitris; Demertzi, Kleoniki; Colombani, Nicolo; Mastrocicco, Micol; Ghirardini, Andrea; Castaldelli, Giuseppe; Fano, Elisa-Anna

    2017-08-01

    The objective of the study is to provide global grids (0.5°) of revised annual coefficients for the Priestley-Taylor (P-T) and Hargreaves-Samani (H-S) evapotranspiration methods after calibration based on the ASCE (American Society of Civil Engineers)-standardized Penman-Monteith method (the ASCE method includes two reference crops: short-clipped grass and tall alfalfa). The analysis also includes the development of a global grid of revised annual coefficients for solar radiation (Rs) estimations using the respective Rs formula of H-S. The analysis was based on global gridded climatic data of the period 1950-2000. The method for deriving annual coefficients of the P-T and H-S methods was based on partial weighted averages (PWAs) of their mean monthly values. This method estimates the annual values considering the amplitude of the parameter under investigation (ETo and Rs) giving more weight to the monthly coefficients of the months with higher ETo values (or Rs values for the case of the H-S radiation formula). The method also eliminates the effect of unreasonably high or low monthly coefficients that may occur during periods where ETo and Rs fall below a specific threshold. The new coefficients were validated based on data from 140 stations located in various climatic zones of the USA and Australia with expanded observations up to 2016. The validation procedure for ETo estimations of the short reference crop showed that the P-T and H-S methods with the new revised coefficients outperformed the standard methods reducing the estimated root mean square error (RMSE) in ETo values by 40 and 25 %, respectively. The estimations of Rs using the H-S formula with revised coefficients reduced the RMSE by 28 % in comparison to the standard H-S formula. Finally, a raster database was built consisting of (a) global maps for the mean monthly ETo values estimated by ASCE-standardized method for both reference crops, (b) global maps for the revised annual coefficients of the P

  5. The advantages of a standardized linguistic reference set in managing the company's knowledge and know-how

    International Nuclear Information System (INIS)

    Penot, N.; Abemonti, F.; Cayzergues, P.; Pinoche, M.; Talou, C.; Levesque, L.

    1997-01-01

    The company's knowledge and know-how take the concrete form of documents (texts, photographs, video tapes). For purposes of transmission, they must not only be stored, in electronic form today, but also retrieved easily and quickly. To further that end, Gaz de France (GDF) has compiled a bilingual (French, English) thesaurus on the gas industry. The English version was prepared in conjunction with NGTC, Canada's Natural Gas Technologies Center. This thesaurus, comprising descriptors organized according to relationships of genericness, specificity, association and documentary synonymity, is an integral part of the engineers' working enviroment at the NGTC, and GDF. The electronic version facilitates its use by company employees. Constantly available, it is helpful in describing and finding information readily. As a result of studies conducted in this regard: design and maintenance rules have been developed for the thesaurus; the thesaurus has been disseminated to all the engineers in the Company; the thesaurus has been incorporated in the Company's Electronic Document Management system. (au)

  6. Experimental comparison between total calibration factors and components calibration factors of reference dosemeters used in secondary standard laboratory dosemeters

    International Nuclear Information System (INIS)

    Silva, T.A. da.

    1981-06-01

    A quantitative comparison of component calibration factors with the corresponding overall calibration factor was used to evaluate the adopted component calibration procedure in regard to parasitic elements. Judgement of significance is based upon the experimental uncertainty of a well established procedure for determination of the overall calibration factor. The experimental results obtained for different ionization chambers and different electrometers demonstrate that for one type of electrometer the parasitic elements have no influence on its sensitivity considering the experimental uncertainty of the calibration procedures. In this case the adopted procedure for determination of component calibration factors is considered to be equivalent to the procedure of determination of the overall calibration factor and thus might be used as a strong quality control measure in routine calibration. (Author) [pt

  7. Standardization of reflectance measurements in dispersed organic matter: results of an exercise to improve interlaboratory agreement

    Science.gov (United States)

    Hackley, Paul C.; Araujo, Carla Viviane; Borrego, Angeles G.; Bouzinos, Antonis; Cardott, Brian; Cook, Alan C.; Eble, Cortland; Flores, Deolinda; Gentzis, Thomas; Gonçalves, Paula Alexandra; Filho, João Graciano Mendonça; Hámor-Vidó, Mária; Jelonek, Iwona; Kommeren, Kees; Knowles, Wayne; Kus, Jolanta; Mastalerz, Maria; Menezes, Taíssa Rêgo; Newman, Jane; Pawlewicz, Mark; Pickel, Walter; Potter, Judith; Ranasinghe, Paddy; Read, Harold; Reyes, Julito; Rodriguez, Genaro De La Rosa; de Souza, Igor Viegas Alves Fernandes; Suarez-Ruiz, Isabel; Sýkorová, Ivana; Valentine, Brett J.

    2015-01-01

    Vitrinite reflectance generally is considered the most robust thermal maturity parameter available for application to hydrocarbon exploration and petroleum system evaluation. However, until 2011 there was no standardized methodology available to provide guidelines for vitrinite reflectance measurements in shale. Efforts to correct this deficiency resulted in publication of ASTM D7708: Standard test method for microscopical determination of the reflectance of vitrinite dispersed in sedimentary rocks. In 2012-2013, an interlaboratory exercise was conducted to establish precision limits for the D7708 measurement technique. Six samples, representing a wide variety of shale, were tested in duplicate by 28 analysts in 22 laboratories from 14 countries. Samples ranged from immature to overmature (0.31-1.53% Ro), from organic-lean to organic-rich (1-22 wt.% total organic carbon), and contained Type I (lacustrine), Type II (marine), and Type III (terrestrial) kerogens. Repeatability limits (maximum difference between valid repetitive results from same operator, same conditions) ranged from 0.03-0.11% absolute reflectance, whereas reproducibility limits (maximum difference between valid results obtained on same test material by different operators, different laboratories) ranged from 0.12-0.54% absolute reflectance. Repeatability and reproducibility limits degraded consistently with increasing maturity and decreasing organic content. However, samples with terrestrial kerogens (Type III) fell off this trend, showing improved levels of reproducibility due to higher vitrinite content and improved ease of identification. Operators did not consistently meet the reporting requirements of the test method, indicating that a common reporting template is required to improve data quality. The most difficult problem encountered was the petrographic distinction of solid bitumens and low-reflecting inert macerals from vitrinite when vitrinite occurred with reflectance ranges overlapping

  8. Scoliosis short-term rehabilitation (SSTR according to 'Best Practice' standards - are the results repeatable?

    Directory of Open Access Journals (Sweden)

    Borysov Maksym

    2012-01-01

    Full Text Available Abstract Claims have been made in a pilot study that a new form of short-term rehabilitation according to 'Best Practice' standards would change signs and symptoms of patients with scoliosis in the short-term. Aim of this study is to repeat the study published 2010 with a larger sample of patients using the same protocol. Both authors have undergone training in this special approach to scoliosis rehabilitation in 2010. Materials and methods 34 patients with Adolescent Idiopathic Scoliosis (AIS, 32 girls and 2 boys, average age 13.7 years and an average Cobb angle of 28.7 degrees (21-43 degrees underwent Scoliosis Short-Term Rehabilitation (SSTR of seven days. Two days with an intensity of 3 × 90 min sessions/day, and five days with an intensity of 2 × 60 min sessions/day. Angle of trunk rotation (ATR was measured before and after the time of treatment as well as the active correctability of the ATR after the programme as it has been done in the pilot investigation. Additionally to that, we also recorded the changes in Vital Capacity (VC before and after the programme. Results ATR was reduced significantly from 11,5 degrees to 8,4 degrees, the active correctability as measured with the Scoliometer (TM was also reduced significantly from the ATR after treatment 8,9 degrees to 6,5 degrees in the patients with thoracic curves. VC improved significantly (P Discussion The results achieved in the pilot investigation published previously are repeatable. The deformity of the trunk can be reduced significantly after SSTR. During the pilot study VC was not investigated. In our study VC improved significantly. Therefore, also shorter rehabilitation times with an appropriate programme seem to be able to change signs and symptoms of a patient with scoliosis. Like the out-patient Schroth programme as described in a study from Turkey, the SSTR provides benefits leading to an improvement of the condition. Conclusion Out-patient rehabilitation following the

  9. Standard practice for analysis and interpretation of physics dosimetry results for test reactors

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    This practice describes the methodology summarized in Annex Al to be used in the analysis and interpretation of physics-dosimetry results from test reactors. This practice relies on, and ties together, the application of several supporting ASTM standard practices, guides, and methods that are in various stages of completion (see Fig. 1). Support subject areas that are discussed include reactor physics calculations, dosimeter selection and analysis, exposure units, and neutron spectrum adjustment methods. This practice is directed towards the development and application of physics-dosimetrymetallurgical data obtained from test reactor irradiation experiments that are performed in support of the operation, licensing, and regulation of LWR nuclear power plants. It specifically addresses the physics-dosimetry aspects of the problem. Procedures related to the analysis, interpretation, and application of both test and power reactor physics-dosimetry-metallurgy results are addressed in Practice E 853, Practice E 560, Matrix E 706(IE), Practice E 185, Matrix E 706(IG), Guide E 900, and Method E 646

  10. Result of standard patch test in patients suspected of having allergic contact dermatitis.

    Science.gov (United States)

    Wongpiyabovorn, Jongkonnee; Puvabanditsin, Porntip

    2005-09-01

    Contact dermatitis is a common skin disease. Disease was diagnosed by a history of contact substance together with geographic distribution of lesion. Up till now, standard patch test is one of the most reliable test to identify and confirm causative agent of allergic contact dermatitis. To determine the rate of positive standard patch test and to identify the common allergen of contact dermatitis in Thailand, we performed the standard patch test in 129 patients, suspected having allergic contact dermatitis at Department of Dermatology, King Chulalongkorn Memorial Hospital, Thailand from June 1, 2003 to September 1, 2004. The rate of positive standard patch test is 59.7% (n = 77/129). The most 3 common positive allergens were nickel sulfate (18.60%), cobalt chloride (17.05%) and fragrance mix (14.73%), respectively. The chance of positive standard patch test significantly correlated with sex (woman), initial diagnosis as contact dermatitis and history of house-worker (p = 0.017, p = 0.005 and p = 0.023, respectively). Whereas, there were no significant correlation between the chance of positive standard patch test and age of patient, location of lesion, history of recurrence, history of atopy, history of drug and food allergy. In addition, history of metal allergy significantly correlated with the chance of positive nickel sulfate or cobalt chloride in standard patch test (p = 0.017). In conclusion, this study demonstrated the prevalence of causative allergen of contact dermatitis in Thai patients using that standard patch test. Moreover, our data shown that the chance positive standard patch test was greater in patient, who were women or initial diagnosed as contact dermatitis or had history of houseworker or history of metal allergy.

  11. Results of international standard problem No. 36 severe fuel damage experiment of a VVER fuel bundle

    Energy Technology Data Exchange (ETDEWEB)

    Firnhaber, M. [Gesellschaft fuer Anlagen-und Reaktorsicherheit, Koeln (Germany); Yegorova, L. [Nuclear Safety Institute of Russian Research Center, Moscow (Russian Federation); Brockmeier, U. [Ruhr-Univ. of Bochum (Germany)] [and others

    1995-09-01

    International Standard Problems (ISP) organized by the OECD are defined as comparative exercises in which predictions with different computer codes for a given physical problem are compared with each other and with a carefully controlled experimental study. The main goal of ISP is to increase confidence in the validity and accuracy of analytical tools used in assessing the safety of nuclear installations. In addition, it enables the code user to gain experience and to improve his competence. This paper presents the results and assessment of ISP No. 36, which deals with the early core degradation phase during an unmitigated severe LWR accident in a Russian type VVER. Representatives of 17 organizations participated in the ISP using the codes ATHLET-CD, ICARE2, KESS-III, MELCOR, SCDAP/RELAP5 and RAPTA. Some participants performed several calculations with different codes. As experimental basis the severe fuel damage experiment CORA-W2 was selected. The main phenomena investigated are thermal behavior of fuel rods, onset of temperature escalation, material behavior and hydrogen generation. In general, the calculations give the right tendency of the experimental results for the thermal behavior, the hydrogen generation and, partly, for the material behavior. However, some calculations deviate in important quantities - e.g. some material behavior data - showing remarkable discrepancies between each other and from the experiments. The temperature history of the bundle up to the beginning of significant oxidation was calculated quite well. Deviations seem to be related to the overall heat balance. Since the material behavior of the bundle is to a great extent influenced by the cladding failure criteria a more realistic cladding failure model should be developed at least for the detailed, mechanistic codes. Regarding the material behavior and flow blockage some models for the material interaction as well as for relocation and refreezing requires further improvement.

  12. Non-SUSY Beyond Standard Model Searches: Recent Results from ATLAS and CMS

    OpenAIRE

    Malek, Fairouz

    2015-01-01

    The Standard Model of particle physics is a sensational success, especially since the discovery of the 125 GeV Higgs boson. However, there are still numerous unanswered questions. Why is the Higgs so light? Do the interactions couplings unify and how can gravity be included? Why three fermion generations? What is dark matter? Theories Beyond the Standard Model (BSM), such as Grand Unified Theories, Extra Dimensions or Technicolour are trying to answer these questions. In this proceedings, we ...

  13. Substoichiometric isotope dilution analysis of arsenic in biological and environmental standard reference materials by solvent extraction using toluene-3,4-dithiol in benzene

    International Nuclear Information System (INIS)

    Chutke, N.L.; Ambulkar, Ms.M.N.; Weginwar, R.G.; Garg, A.N.

    1994-01-01

    A radiochemical solvent extraction procedure has been developed for the determination of As(III) using 76 As tracer. It is based on the complexation of As(III) with toluene-3,4-dithiol (TDT) at pH 2 and subsequent extraction in benzene. The effect of various parameters such as pH, time of equilibration, nature of solvent, quantitative character and interferences have been studied. The method has been further developed into substoichiometric isotope dilution analysis for the determination of As at < 1μg level and employed for the analysis of several environmental and biological standard Reference Materials from NIST (USA), IAEA (Vienna) and NIES (Japan). (author) 39 refs.; 4 figs.; 4 tabs

  14. Use of fat mass and fat free mass standard deviation scores obtained using simple measurement methods in healthy children and patients: comparison with the reference 4-component model.

    Science.gov (United States)

    Atherton, Rachel R; Williams, Jane E; Wells, Jonathan C K; Fewtrell, Mary S

    2013-01-01

    Clinical application of body composition (BC) measurements for individual children has been limited by lack of appropriate reference data. (1) To compare fat mass (FM) and fat free mass (FFM) standard deviation scores (SDS) generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C) model; (2) To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy), BMI and skinfold thicknesses (SFT); and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height(2)/Z)) in 927 subjects aged 3.8-22.0 y (211 healthy, 716 patients). DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement) FM SDS 0.03 (± 0.62); FFM SDS -0.04 (± 0.72)), and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤-2 or ≥ 2). BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome.

  15. New reference values for body composition by bioelectrical impedance analysis in the general population: results from the UK Biobank.

    Science.gov (United States)

    Franssen, Frits M E; Rutten, Erica P A; Groenen, Miriam T J; Vanfleteren, Lowie E; Wouters, Emiel F M; Spruit, Martijn A

    2014-06-01

    Low fat-free mass (FFM) is a risk factor for morbidity and mortality in elderly and patient populations. Therefore, measurement of FFM is important in nutritional assessment. Bioelectrical impedance analysis (BIA) is a convenient method to assess FFM and FFM index (FFMI; FFM/height(2)). Although reference values have been established for individuals with normal body weight, no specific cutoff values are available for overweight and obese populations. Also, limited studies accounted for the age-related decline in FFM. To determine BMI- and age-specific reference values for abnormal low FFM(I) in white-ethnic men and women free of self-reported disease from the general population. The UK Biobank is a prospective epidemiological study of the general population from the United Kingdom. Individuals in the age category 45 to 69 years were analyzed. In addition to body weight, FFM and FFMI were measured using a Tanita BC-418MA. Also, self-reported chronic conditions and ethnic background were registered, and lung function was assessed using spirometry. After exclusion of all individuals with missing data, nonwhite ethnicity, self-reported disease, body mass index (BMI) less than 14 or 36 kg/m(2) or higher, and/or an obstructive lung function, reference values for FFM and FFMI were derived from 186,975 individuals (45.9% men; age: 56.9 ± 6.8 years; BMI: 26.5 ± 3.6 kg/m(2); FFMI 18.3 ± 2.4 kg/m(2)). FFM and FFMI were significantly associated with BMI and decreased with age. Percentiles 5, 10, 25, 50, 75, 90, and 95 were calculated for FFM, FFMI, and fat mass (index), after stratification for gender, age, and BMI. Using the UK Biobank dataset, new reference values for body composition assessed with BIA were determined in white-ethnic men and women aged 45 to 69 years. Because these reference values are BMI specific, they are of broad interest for overweight and obese populations. Copyright © 2014 American Medical Directors Association, Inc. Published by Elsevier Inc. All

  16. Towards reporting standards for neuropsychological study results: A proposal to minimize communication errors with standardized qualitative descriptors for normalized test scores.

    Science.gov (United States)

    Schoenberg, Mike R; Rum, Ruba S

    2017-11-01

    Rapid, clear and efficient communication of neuropsychological results is essential to benefit patient care. Errors in communication are a lead cause of medical errors; nevertheless, there remains a lack of consistency in how neuropsychological scores are communicated. A major limitation in the communication of neuropsychological results is the inconsistent use of qualitative descriptors for standardized test scores and the use of vague terminology. PubMed search from 1 Jan 2007 to 1 Aug 2016 to identify guidelines or consensus statements for the description and reporting of qualitative terms to communicate neuropsychological test scores was conducted. The review found the use of confusing and overlapping terms to describe various ranges of percentile standardized test scores. In response, we propose a simplified set of qualitative descriptors for normalized test scores (Q-Simple) as a means to reduce errors in communicating test results. The Q-Simple qualitative terms are: 'very superior', 'superior', 'high average', 'average', 'low average', 'borderline' and 'abnormal/impaired'. A case example illustrates the proposed Q-Simple qualitative classification system to communicate neuropsychological results for neurosurgical planning. The Q-Simple qualitative descriptor system is aimed as a means to improve and standardize communication of standardized neuropsychological test scores. Research are needed to further evaluate neuropsychological communication errors. Conveying the clinical implications of neuropsychological results in a manner that minimizes risk for communication errors is a quintessential component of evidence-based practice. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Antropometria de atletas culturistas em relação à referência populacional Anthropometry of body builders in relation to the population standard

    Directory of Open Access Journals (Sweden)

    Naílza MAESTÁ

    2000-08-01

    Full Text Available Atletas de culturismo têm como alvo de treinamento a hipertrofia muscular e a redução da adiposidade. A falta de referências antropométricas apropriadas pode levar esses indivíduos a serem erroneamente considerados em situação de sobrepeso ou desnutrição. Portanto, objetivamos comparar a composição corporal de atletas de culturismo com os padrões populacionais. Foram avaliados 36 atletas, de ambos os sexos, 26 do sexo masculino (27,2 ± 7,2 anos e 10 do sexo feminino (30,0 ± 6,1 anos, por ocasião da competição nacional, quanto aos indicadores antropométricos de peso, estatura, índice de massa corpórea, pregas cutâneas, adiposidade corpórea e circunferência muscular do braço. Os resultados foram referidos quanto à posição percentual ou de desvios-padrão (pelo escore Z tendo como referências padrões populacionais locais. Como resultado, encontramos que os indicadores com menor contraste com os padrões adotados foram peso e estatura e os maiores contrastes foram encontrados na circunferência muscular do braço para os homens, e pregas cutâneas tricipital para as mulheres. Pelo indicador muscular todos foram classificados como obesos ou sobrepeso, enquanto que pela prega cutânea tricipital e adiposidade corpórea, a desnutrição esteve presente em 100,0% das mulheres e 88,5% dos homens. Fica evidenciada a inadequação da utilização do padrão antropométrico populacional para a classificação nutricional de atletas de força, em particular culturistas, sendo assim necessário o estabelecimento de padrões próprios para esse tipo de treinamento (modalidade.Body builders have as their training goals the maximum muscle hypertrophy with minimum adiposity. However, the scarcity of specific standards implies often in framing wrongly those athletes either as overweight (by their BMI or energy malnourished (by their fat stores. The objective of this study was to compare the body composition of body builders with

  18. ['Gold standard', not 'golden standard'

    NARCIS (Netherlands)

    Claassen, J.A.H.R.

    2005-01-01

    In medical literature, both 'gold standard' and 'golden standard' are employed to describe a reference test used for comparison with a novel method. The term 'gold standard' in its current sense in medical research was coined by Rudd in 1979, in reference to the monetary gold standard. In the same

  19. Comparison study for the CCME reference method for determination of PHC in soil by using internal and external standard methods and by using silica gel column cleanup and in-situ silica gel cleanup methods

    International Nuclear Information System (INIS)

    Wang, Z.; Fingas, M.; Sigouin, L.; Yang, C.; Hollebone, B.

    2003-01-01

    The assessment, cleanup, and remediation of hydrocarbon contaminated sites is covered in the Reference Method for Canada-Wide Standard for Petroleum Hydrocarbons-Tier 1 Method. It replaces several analytical methods used in the past by some laboratories and jurisdictions in Canada. The authors conducted two comparative evaluations to validate the Tier 1 Analytical Method. The first compared the Internal and External Standard Methods, and the second compared the Silica Gel Column Cleanup Method with the In-situ Silica Gel Cleanup Method. The Canadian Council of Ministers of the Environment (CCME) Tier 1 Method recommends and requires the External Standard Method to determine petroleum hydrocarbons (PHC) in soil samples. The Internal Method is widely used to quantify various organic and inorganic pollutants in environmental samples. The Tier 1 Method offers two options for the same extract cleanup. They are: Option A - In-situ Silica Gel Cleanup, and Option B - Silica Gel Column Cleanup. Linearity, precision, and PHC quantification results were the parameters considered for diesel and motor oil solutions, for diesel spiked soil samples, and for motor oil spiked soil samples. It was concluded that both the External and Internal Standard Methods for gas chromatograph (GC) determination of PHC in soil possess their own advantages. The PHC results obtained using the In-Situ Silica Gel Cleanup Method were lower than those obtained with the Silica Gel Column Cleanup Methods. The more efficient and effective sample cleanup method proved to be the Silica Gel Column Method. 13 refs., 7 tabs., 7 figs

  20. The Clinical Utility of ASRS-v1.1 for Identifying ADHD in Alcoholics Using PRISM as the Reference Standard.

    Science.gov (United States)

    Reyes, Maria M; Schneekloth, Terry D; Hitschfeld, Mario J; Geske, Jennifer R; Atkinson, David L; Karpyak, Victor M

    2016-05-02

    The objective was to assess the clinical utility of the Adult ADHD Self-Report Scale (ASRS-v1.1) in identifying ADHD in alcoholics using the Psychiatric Research Interview for Substance and Mental Disorders (PRISM) as the diagnostic "gold standard." We performed a secondary analysis of data from 379 treatment-seeking alcoholics who completed the ASRS-v1.1 and the ADHD module of the PRISM. Data analysis included descriptive statistics. The prevalence of ADHD was 7.7% (95% CI = [5.4, 10.8]). The positive predictive value (PPV) of the ASRS-v1.1 was 18.1% (95% CI = [12.4, 25.7]) and the negative predictive value (NPV) was 97.6% (95% CI = [94.9, 98.9]). The ASRS-v1.1 demonstrated a sensitivity of 79.3% (95% CI = [61.6, 90.2]) and a specificity of 70.3% (95% CI = [65.3, 74.8]). The ASRS-v1.1 demonstrated acceptable sensitivity and specificity in a sample of treatment-seeking alcoholics when compared with the PRISM as the reference standard for ADHD diagnosis. © The Author(s) 2016.

  1. Isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS) for the certification of lead and cadmium in environmental standard reference materials.

    Science.gov (United States)

    Murphy, K E; Beary, E S; Rearick, M S; Vocke, R D

    2000-10-01

    Lead (Pb) and cadmium (Cd) have been determined in six new environmental standard reference materials (SRMs) using isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS). The SRMs are the following: SRM 1944, New York-New Jersey Waterway Sediment, SRMs 2583 and 2584, Trace Elements in Indoor Dust, Nominal 90 mg/kg and 10,000 mg/kg Lead, respectively, SRMs 2586 and 2587, Trace Elements in Soil Containing Lead from Paint, Nominal 500 mg/kg and 3,000 mg/kg Lead, respectively, and SRM 2782, Industrial Sludge. The capabilities of ID ICP-MS for the certification of Pb and Cd in these materials are assessed. Sample preparation and ratio measurement uncertainties have been evaluated. Reproducibility and accuracy of the established procedures are demonstrated by determination of gravimetrically prepared primary standard solutions and by comparison with isotope dilution thermal ionization mass spectrometry (ID TIMS). Material heterogeneity was readily demonstrated to be the dominant source of uncertainty in the certified values.

  2. Bayesian modeling and inference for diagnostic accuracy and probability of disease based on multiple diagnostic biomarkers with and without a perfect reference standard.

    Science.gov (United States)

    Jafarzadeh, S Reza; Johnson, Wesley O; Gardner, Ian A

    2016-03-15

    The area under the receiver operating characteristic (ROC) curve (AUC) is used as a performance metric for quantitative tests. Although multiple biomarkers may be available for diagnostic or screening purposes, diagnostic accuracy is often assessed individually rather than in combination. In this paper, we consider the interesting problem of combining multiple biomarkers for use in a single diagnostic criterion with the goal of improving the diagnostic accuracy above that of an individual biomarker. The diagnostic criterion created from multiple biomarkers is based on the predictive probability of disease, conditional on given multiple biomarker outcomes. If the computed predictive probability exceeds a specified cutoff, the corresponding subject is allocated as 'diseased'. This defines a standard diagnostic criterion that has its own ROC curve, namely, the combined ROC (cROC). The AUC metric for cROC, namely, the combined AUC (cAUC), is used to compare the predictive criterion based on multiple biomarkers to one based on fewer biomarkers. A multivariate random-effects model is proposed for modeling multiple normally distributed dependent scores. Bayesian methods for estimating ROC curves and corresponding (marginal) AUCs are developed when a perfect reference standard is not available. In addition, cAUCs are computed to compare the accuracy of different combinations of biomarkers for diagnosis. The methods are evaluated using simulations and are applied to data for Johne's disease (paratuberculosis) in cattle. Copyright © 2015 John Wiley & Sons, Ltd.

  3. The IPEM code of practice for determination of the reference air kerma rate for HDR 192Ir brachytherapy sources based on the NPL air kerma standard

    International Nuclear Information System (INIS)

    Bidmead, A M; Sander, T; Nutbrown, R F; Locks, S M; Lee, C D; Aird, E G A; Flynn, A

    2010-01-01

    This paper contains the recommendations of the high dose rate (HDR) brachytherapy working party of the UK Institute of Physics and Engineering in Medicine (IPEM). The recommendations consist of a Code of Practice (COP) for the UK for measuring the reference air kerma rate (RAKR) of HDR 192 Ir brachytherapy sources. In 2004, the National Physical Laboratory (NPL) commissioned a primary standard for the realization of RAKR of HDR 192 Ir brachytherapy sources. This has meant that it is now possible to calibrate ionization chambers directly traceable to an air kerma standard using an 192 Ir source (Sander and Nutbrown 2006 NPL Report DQL-RD 004 (Teddington: NPL) http://publications.npl.co.uk). In order to use the source specification in terms of either RAKR, .K R (ICRU 1985 ICRU Report No 38 (Washington, DC: ICRU); ICRU 1997 ICRU Report No 58 (Bethesda, MD: ICRU)), or air kerma strength, S K (Nath et al 1995 Med. Phys. 22 209-34), it has been necessary to develop algorithms that can calculate the dose at any point around brachytherapy sources within the patient tissues. The AAPM TG-43 protocol (Nath et al 1995 Med. Phys. 22 209-34) and the 2004 update TG-43U1 (Rivard et al 2004 Med. Phys. 31 633-74) have been developed more fully than any other protocol and are widely used in commercial treatment planning systems. Since the TG-43 formalism uses the quantity air kerma strength, whereas this COP uses RAKR, a unit conversion from RAKR to air kerma strength was included in the appendix to this COP. It is recommended that the measured RAKR determined with a calibrated well chamber traceable to the NPL 192 Ir primary standard is used in the treatment planning system. The measurement uncertainty in the source calibration based on the system described in this COP has been reduced considerably compared to other methods based on interpolation techniques.

  4. Improvement in operating characteristics resulting from the addition of FLIP fuel to a standard TRIGA core

    International Nuclear Information System (INIS)

    Randall, J.D.; Feltz, D.E.; Godsey, T.A.; Schumacher, R.F.

    1974-01-01

    To overcome problems associated with fuel burnup the Nuclear Science Center of Texas A and M University decided to convert from standard TRIGA fuel to FLIP-TRIGA fuel. FLIP fuel, which incorporates erbium as a burnable poison and is enriched to 70 percent in U-235, has a calculated lifetime of 9/MW-years. Due to limited funds a core was designed with a central region of 35 FLIP elements surrounded by 63 standard elements. Calculations indicated that the core excess and neutron fluxes were satisfactory, but no prediction was made of the improvements in core lifetime. The reactivity loss due to burnup for a standard core was measured to be 1.54 cents/MW-day. The addition of 35 FLIP fuel elements has reduced this value to approximately 0.5 cents/MW-day. The incorporation of FLIP fuel has, therefore, increased the lifetime of the core by a factor of three using fuel that is only 20 percent more expensive. The mixed core has other advantages as well. The power coefficient is less, the effect of xenon is less, and the fluxes in experimental facilities are higher. Thus, the mixed core has significant advantages over standard TRIGA fuel. (U.S.)

  5. Assessing the Promise of Standards-Based Performance Evaluation for Principals: Results from a Randomized Trial

    Science.gov (United States)

    Kimball, Steven Miller; Milanowski, Anthony; McKinney, Sarah A.

    2009-01-01

    Principals (N = 76) in a large western U.S. school district were randomly assigned to be evaluated using either a new standards-based system or to continue with the old system. It was hypothesized that principals evaluated with the new system would report clearer performance expectations, better feedback, greater fairness and system satisfaction,…

  6. Use of a United States-based laboratory as a hematopathology reference center for a developing country: logistics and results.

    Science.gov (United States)

    Deetz, C O; Scott, M G; Ladenson, J H; Seyoum, M; Hassan, A; Kreisel, F H; Nguyen, T T; Frater, J L

    2013-02-01

    With proper logistical support and sponsorship, a laboratory in an industrialized nation might be able to act as a reference laboratory for clinicians based in a developing country. We built on previous experience in the clinical laboratory to see whether a specialized histopathology service (hematopathology) could be provided to a developing country without the expertise or experience to do it in country. Over an 13-year period, 582 cases from 579 individuals were analyzed. Principal pathologic findings included acute leukemia in 84 cases (14%), dyspoiesis in one or more of the hematopoietic lineages in 65 cases (11%, including three cases with high-grade myelodysplasia), 23 cases (4%) with findings suspicious for a chronic myeloproliferative disorder, 35 cases (6%) with findings suspicious for a lymphoproliferative disorder, and infectious organisms (presumably Leishmania in most instances) in 9 (1%) of cases. Specimens from 45 cases (8%) were unsatisfactory owing to extreme hemodilution and/or specimen degeneration. With proper support, a medical laboratory in an industrialized nation may serve as a reference facility for a developing nation. The use of existing infrastructure may be remarkably effective to achieve optimal turnaround time. Although the lack of ancillary studies and follow-up biopsies limit the ability to achieve a definitive diagnosis in many cases, this must be viewed in the context of the limited ability to diagnose or manage hematopoietic neoplasia in developing nations. © 2012 Blackwell Publishing Ltd.

  7. Reference sources for the calibration of surface contamination monitors - Beta-emitters (maximum beta energy greater than MeV) and alpha-emitters (International Standard Publication ISO 8769:1988)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    This International Standard specifies the characteristics of reference sources of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This International Standard relates to alpha-emitters and to beta-emitters of maximum beta energy greater than 0,15 MeV. It does not describe the procedures involved in the use of these reference sources for the calibration of surface contamination monitors. Such procedures are specified in IEC Publication 325 and other documents. This International Standard specifies reference radiations for the calibration of surface contamination monitors which take the form of adequately characterized large area sources specified, without exception, in terms of activity and surface emission rate, the evaluation of these quantities being traceable to national standards

  8. Uranium reference materials

    International Nuclear Information System (INIS)

    Donivan, S.; Chessmore, R.

    1987-07-01

    The Technical Measurements Center has prepared uranium mill tailings reference materials for use by remedial action contractors and cognizant federal and state agencies. Four materials were prepared with varying concentrations of radionuclides, using three tailings materials and a river-bottom soil diluent. All materials were ground, dried, and blended thoroughly to ensure homogeneity. The analyses on which the recommended values for nuclides in the reference materials are based were performed, using independent methods, by the UNC Geotech (UNC) Chemistry Laboratory, Grand Junction, Colorado, and by C.W. Sill (Sill), Idaho National Engineering Laboratory, Idaho Falls, Idaho. Several statistical tests were performed on the analytical data to characterize the reference materials. Results of these tests reveal that the four reference materials are homogeneous and that no large systematic bias exists between the analytical methods used by Sill and those used by TMC. The average values for radionuclides of the two data sets, representing an unbiased estimate, were used as the recommended values for concentrations of nuclides in the reference materials. The recommended concentrations of radionuclides in the four reference materials are provided. Use of these reference materials will aid in providing uniform standardization among measurements made by remedial action contractors. 11 refs., 9 tabs

  9. Size-dependent standard deviation for growth rates: empirical results and theoretical modeling.

    Science.gov (United States)

    Podobnik, Boris; Horvatic, Davor; Pammolli, Fabio; Wang, Fengzhong; Stanley, H Eugene; Grosse, I

    2008-05-01

    We study annual logarithmic growth rates R of various economic variables such as exports, imports, and foreign debt. For each of these variables we find that the distributions of R can be approximated by double exponential (Laplace) distributions in the central parts and power-law distributions in the tails. For each of these variables we further find a power-law dependence of the standard deviation sigma(R) on the average size of the economic variable with a scaling exponent surprisingly close to that found for the gross domestic product (GDP) [Phys. Rev. Lett. 81, 3275 (1998)]. By analyzing annual logarithmic growth rates R of wages of 161 different occupations, we find a power-law dependence of the standard deviation sigma(R) on the average value of the wages with a scaling exponent beta approximately 0.14 close to those found for the growth of exports, imports, debt, and the growth of the GDP. In contrast to these findings, we observe for payroll data collected from 50 states of the USA that the standard deviation sigma(R) of the annual logarithmic growth rate R increases monotonically with the average value of payroll. However, also in this case we observe a power-law dependence of sigma(R) on the average payroll with a scaling exponent beta approximately -0.08 . Based on these observations we propose a stochastic process for multiple cross-correlated variables where for each variable (i) the distribution of logarithmic growth rates decays exponentially in the central part, (ii) the distribution of the logarithmic growth rate decays algebraically in the far tails, and (iii) the standard deviation of the logarithmic growth rate depends algebraically on the average size of the stochastic variable.

  10. Size-dependent standard deviation for growth rates: Empirical results and theoretical modeling

    Science.gov (United States)

    Podobnik, Boris; Horvatic, Davor; Pammolli, Fabio; Wang, Fengzhong; Stanley, H. Eugene; Grosse, I.

    2008-05-01

    We study annual logarithmic growth rates R of various economic variables such as exports, imports, and foreign debt. For each of these variables we find that the distributions of R can be approximated by double exponential (Laplace) distributions in the central parts and power-law distributions in the tails. For each of these variables we further find a power-law dependence of the standard deviation σ(R) on the average size of the economic variable with a scaling exponent surprisingly close to that found for the gross domestic product (GDP) [Phys. Rev. Lett. 81, 3275 (1998)]. By analyzing annual logarithmic growth rates R of wages of 161 different occupations, we find a power-law dependence of the standard deviation σ(R) on the average value of the wages with a scaling exponent β≈0.14 close to those found for the growth of exports, imports, debt, and the growth of the GDP. In contrast to these findings, we observe for payroll data collected from 50 states of the USA that the standard deviation σ(R) of the annual logarithmic growth rate R increases monotonically with the average value of payroll. However, also in this case we observe a power-law dependence of σ(R) on the average payroll with a scaling exponent β≈-0.08 . Based on these observations we propose a stochastic process for multiple cross-correlated variables where for each variable (i) the distribution of logarithmic growth rates decays exponentially in the central part, (ii) the distribution of the logarithmic growth rate decays algebraically in the far tails, and (iii) the standard deviation of the logarithmic growth rate depends algebraically on the average size of the stochastic variable.

  11. DICOM for quantitative imaging biomarker development: a standards based approach to sharing clinical data and structured PET/CT analysis results in head and neck cancer research.

    Science.gov (United States)

    Fedorov, Andriy; Clunie, David; Ulrich, Ethan; Bauer, Christian; Wahle, Andreas; Brown, Bartley; Onken, Michael; Riesmeier, Jörg; Pieper, Steve; Kikinis, Ron; Buatti, John; Beichel, Reinhard R

    2016-01-01

    Background. Imaging biomarkers hold tremendous promise for precision medicine clinical applications. Development of such biomarkers relies heavily on image post-processing tools for automated image quantitation. Their deployment in the context of clinical research necessitates interoperability with the clinical systems. Comparison with the established outcomes and evaluation tasks motivate integration of the clinical and imaging data, and the use of standardized approaches to support annotation and sharing of the analysis results and semantics. We developed the methodology and tools to support these tasks in Positron Emission Tomography and Computed Tomography (PET/CT) quantitative imaging (QI) biomarker development applied to head and neck cancer (HNC) treatment response assessment, using the Digital Imaging and Communications in Medicine (DICOM(®)) international standard and free open-source software. Methods. Quantitative analysis of PET/CT imaging data collected on patients undergoing treatment for HNC was conducted. Processing steps included Standardized Uptake Value (SUV) normalization of the images, segmentation of the tumor using manual and semi-automatic approaches, automatic segmentation of the reference regions, and extraction of the volumetric segmentation-based measurements. Suitable components of the DICOM standard were identified to model the various types of data produced by the analysis. A developer toolkit of conversion routines and an Application Programming Interface (API) were contributed and applied to create a standards-based representation of the data. Results. DICOM Real World Value Mapping, Segmentation and Structured Reporting objects were utilized for standards-compliant representation of the PET/CT QI analysis results and relevant clinical data. A number of correction proposals to the standard were developed. The open-source DICOM toolkit (DCMTK) was improved to simplify the task of DICOM encoding by introducing new API abstractions

  12. Actual survey of dose evaluation method for standardization of radiation therapy techniques. With special reference to display method of radiation doses

    International Nuclear Information System (INIS)

    Kumagai, Kozo; Yoshiura, Takao; Izumi, Takashi; Araki, Fujio; Takada, Takuo; Jingu, Kenichi.

    1994-01-01

    This report presents the results of questionnaire survey for actual conditions of radiation therapy, which was conducted with the aim of establishing the standardization of radiation therapy techniques. Questionnaires were sent to 100 facilities in Japan, and 86 of these answered, consisting of 62 university hospitals, 2 national hospitals, 14 cancer centers, 4 prefectural or municipal hospitals, and 4 other hospitals. In addition to electron beam therapy, the following typical diseases for radiation therapy were selected as standard irradiation models: cancers of the larynx, esophagus, breast, and uterine cervix, and malignant lymphomas. According to these models, questionnaire results are analyzed in terms of the following four items: (1) irradiation procedures, (2) energy used for radiotherapy, (3) the depth for calculating target absorption doses, and (4) points for displaying target absorption doses. (N.K.)

  13. Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard.

    Science.gov (United States)

    Kaswin, Godefroy; Rousseau, Antoine; Mgarrech, Mohamed; Barreau, Emmanuel; Labetoulle, Marc

    2014-04-01

    To evaluate the agreement in axial length (AL), keratometry (K), anterior chamber depth (ACD) measurements; intraocular lens (IOL) power calculations; and predictability using a new partial coherence interferometry (PCI) optical biometer (AL-Scan) and a reference (gold standard) PCI optical biometer (IOLMaster 500). Service d'Ophtalmologie, Hopital Bicêtre, APHP Université, Paris, France. Evaluation of a diagnostic device. One eye of consecutive patients scheduled for cataract surgery was measured. Biometry was performed with the new biometer and the reference biometer. Comparisons were performed for AL, average K at 2.4 mm, ACD, IOL power calculations with the Haigis and SRK/T formulas, and postoperative predictability of the devices. A P value less than 0.05 was statistically significant. The study enrolled 50 patients (mean age 72.6 years±4.2 SEM). There was a good correlation between biometers for AL, K, and ACD measurements (r=0.999, r=0.933, and r=0.701, respectively) and between IOL power calculation with the Haigis formula (r=0.972) and the SRK/T formula (r=0.981). The mean absolute error (MAE) in IOL power prediction was 0.42±0.08 diopter (D) with the new biometer and 0.44±0.08 D with the reference biometer. The MAE was 0.20 D with the Haigis formula and 0.19 with the SRK/T formula (P=.36). The new PCI biometer provided valid measurements compared with the current gold standard, indicating that the new device can be used for IOL power calculations for routine cataract surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Results from heater-induced quenches of A 4.5 m Reference Design D dipole for the SSC

    International Nuclear Information System (INIS)

    Ganetis, G.; Prodell, A.

    1986-01-01

    Quench studies were performed using a 4.5 m long Reference Design D, SSC dipole to determine the temperature rise of the magnet conductor during a quench by measuring the resistance of the conductor cable in the immediate vicinity of the quench. The single bore magnet was wound with improved NbTi conductor in a 2-layer cosine θ coil configuration of 4.0 cm inner diameter. Eight pairs of voltage taps were installed at various locations on the right side of the inner coil of the magnet. ''Spot'' heaters were centrally located between the voltage taps of 4 of these pairs on the midplane turn of the inner coil to initiate magnet quenches. A redundant array of voltage taps and heaters was also installed on the left side of the inner coil. The resistance of the conductor was obtained from observations of the current and voltage during a magnet quench. The temperature of the conductor was then determined by comparing its resistance to an R vs T curve appropriate for the conductor. The quantity ∫ I 2 dt and the temperature, T, are presented as a function of current, and the maximum conductor temperature is shown as a function of ∫ I 2 dt. Measured longitudinal and azimuthal quench propagation velocities are also presented as a function of magnet current, and the temperatures at several locations on the inner magnet coil are plotted as a function of the time after a quench was initiated

  15. Determination of reference values for intraocular pressure and Schirmer tear test results in clinically normal domestic donkeys (Equus asinus).

    Science.gov (United States)

    Selk Ghaffari, Masoud; Sabzevari, Amin; Ghamsari, SeyedMehdi; Shad, Hussein

    2017-11-25

    This study was conducted to establish normal reference range for the Schirmer tear test (STT) and intraocular pressure (IOP) in clinically normal donkeys for use in clinical practice. Sixteen adult Ethiopian domestic donkeys were used in this study. Complete ophthalmic examinations were performed without chemical restraint. STT values were evaluated in both eyes of all donkeys using a commercial STT strip. IOP was measured in both eyes with a Tono-Pen Vet (Reichert. USA) without using regional nerve blocks. STT values for all eyes (n=32) were 22.1±6.9 mm/minute with a range of 13-35 mm/minute. Comparison of mean STT values between right (n=16) and left eyes (n=16) showed no differences (P=0.6). Mean ±sd IOP values by applanation tonometry were 17.8±3.7 mmHg (range 13.5-24.5 mmHg). Comparison of mean IOP values between right (n=16) and left eyes (n=16) showed no differences (P=0.7). This initial survey provides means and ranges for IOP and STT values in donkeys. These data will assist veterinary ophthalmologists in more accurate diagnosis and management of ophthalmic diseases in donkeys, including keratoconjunctivitis sicca and glaucoma. © British Veterinary Association (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Experience of Approbation and Target Reference Points of Introduction of the Professional Standard "Pedagogue-Psychologist (Educational psychologist" in Sverdlovsk Region

    Directory of Open Access Journals (Sweden)

    Vasyagina N.N.

    2017-11-01

    Full Text Available The experience of application of the professional standard "Pedagogue-psychologist (educational psychologist" in the Sverdlovsk region is described. A regional model for the application of the professional standard developed on the basis of the principles of unity of centralization and decentralization, interdepartmental and network interaction developed by the authors is presented. The main forms and methods of work on the application of a professional standard in the region are disclosed; the results of the Sverdlovsk region internship site are described, including mechanisms for identifying personnel shortages and development of personalized trajectories of the professional development of psychology teachers in the region. The following are highlighted as priority areas: the development of regional normative legal acts regulating the professional activity of pedagogue-psychologists, the application of the professional standard of the pedagogue-psychologist in the formation of the personnel policy in the field of education, and the modernization of the system of vocational training and additional vocational education of psychologists.

  17. Radionuclide transfer to wildlife at a 'Reference site' in the Chernobyl Exclusion Zone and resultant radiation exposures.

    Science.gov (United States)

    Beresford, N A; Barnett, C L; Gashchak, S; Maksimenko, A; Guliaichenko, E; Wood, M D; Izquierdo, M

    2018-02-27

    This study addresses a significant data deficiency in the developing environmental protection framework of the International Commission on Radiological Protection, namely a lack of radionuclide transfer data for some of the Reference Animals and Plants (RAPs). It is also the first study that has sampled such a wide range of species (invertebrates, plants, amphibians and small mammals) from a single terrestrial site in the Chernobyl Exclusion Zone (CEZ). Samples were collected in 2014 from the 0.4 km 2 sampling site, located 5 km west of the Chernobyl Nuclear Power complex. We report radionuclide ( 137 Cs, 90 Sr, 241 Am and Pu-isotopes) and stable element concentrations in wildlife and soil samples and use these to determine whole organism-soil concentration ratios and absorbed dose rates. Increasingly, stable element analyses are used to provide transfer parameters for radiological models. The study described here found that for both Cs and Sr the transfer of the stable element tended to be lower than that of the radionuclide; this is the first time that this has been demonstrated for Sr, though it is in agreement with limited evidence previously reported for Cs. Studies reporting radiation effects on wildlife in the CEZ generally relate observations to ambient dose rates determined using handheld dose meters. For the first time, we demonstrate that ambient dose rates may underestimate the actual dose rate for some organisms by more than an order of magnitude. When reporting effects studies from the CEZ, it has previously been suggested that the area has comparatively low natural background dose rates. However, on the basis of data reported here, dose rates to wildlife from natural background radionuclides within the CEZ are similar to those in many areas of Europe. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Diagnostic performance of in vivo 3-T MRI for articular cartilage abnormalities in human osteoarthritic knees using histology as standard of reference

    International Nuclear Information System (INIS)

    Saadat, Ehsan; Jobke, Bjoern; Chu, Bill; Lu, Ying; Cheng, Jonathan; Li, Xiaojuan; Majumdar, Sharmila; Link, Thomas M.; Ries, Michael D.

    2008-01-01

    The purpose of this study was (1) to evaluate the sensitivity, specificity and accuracy of sagittal in vivo 3-T intermediate-weighted fast spin-echo (iwFSE) sequences in the assessment of knee cartilage pathologies using histology as the reference standard in patients undergoing total knee replacement, and (2) to correlate MR imaging findings typically associated with osteoarthritis such as bone marrow edema pattern (BMEP) and cartilage swelling with histological findings. Tibial plateaus and femoral condyles of eight knees of seven patients were resected during surgery, and sagittal histological sections were prepared for histology. Preoperative MRI findings were compared to the corresponding region in histological sections for thickness, surface integrity and signal pattern of cartilage, and histological findings in areas of BMEP and swelling were documented. The overall sensitivity, specificity and accuracy were 72%, 69% and 70% for thickness, 69%, 74% and 73% for surface and 36%, 62% and 45% for intracartilaginous signal pattern. For all cases of BMEP on MRI subchondral ingrowth of fibrovascular tissue and increased bone remodeling were observed. MRI using fat-saturated iwFSE sequences showed good performance in assessing cartilage thickness and surface lesions, while signal changes of cartilage were not suited to characterize the severity of cartilage degeneration as validated by histology. (orig.)

  19. Determination of trace elements in human blood serum and in the standard reference material ''Bovine Liver'' by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Behne, D.; Juergensen, H.

    1978-01-01

    Ag, Br, Co, Cr, Cs, Fe, Na, Rb, Sb, Se and Zn were determined in biological materials by gamma-spectrometry of long-lived radionuclides after long-time irradiation with thermal neutrons. Blood was taken from a vein in the arm of the test person via an indwelling plastic cannula. The serum was separated from other blood components by centrifugation and stored at a temperature of -20 deg C. Ampoules of high purity silica quartz were chosen as irradiation containers. The vials were cleaned by etching with 40% hydrofluoric acid. For the analysis 300 μl of serum were taken. The ampoules were irradiated for 10 days at a thermal neutron flux density of 5.10 13 n.cm -2 .sec -1 . They were then cleaned by etching for 5 min with hydrofluoric acid. The gamma-ray spectra of the irradiated samples were measured twice. From the first spectra, which were obtained 10 days after irradiation, the concentrations of Br and Na were calculated. From the gamma-peaks after a decay time of 3 months Ag, Co, Cr, Cs, Fe, Rb, Sc, Se and Zn were determined. The accuracy and precision of the procedure were tested, using the standard reference material ''Bovine Liver'' and identical serum samples. In the case of blood serum the method proved to be suitable for the determination of Br, Cs, Fe, Na, Rb, Se and Zn. By analysing samples from several subjects information about element levels in human serum was obtained. (T.G.)

  20. Accuracy of CT chest without oral contrast for ruling out esophageal perforation using fluoroscopic esophagography as reference standard: a retrospective study.

    Science.gov (United States)

    Awais, Muhammad; Qamar, Saqib; Rehman, Abdul; Baloch, Noor Ul-Ain; Shafqat, Gulnaz

    2018-02-26

    Esophageal perforation has a high mortality rate. Fluoroscopic esophagography (FE) is the procedure of choice for diagnosing esophageal perforation. However, FE can be difficult to perform in seriously ill patients. We retrospectively reviewed charts and scans of all patients who had undergone thoracic CT (TCT) without oral contrast and FE for suspicion of esophageal perforation at our hospital between October, 2010 and December, 2015. Scans were interpreted by a single consultant radiologist having > 5 years of relevant experience. Statistical analysis was performed using SPSS version 20. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of TCT were computed using FE as reference standard. Of 122 subjects, 106 (83%) were male and their median age was 42 [inter-quartile range (IQR) 29-53] years. Esophageal perforation was evident on FE in 15 (8%) cases. Sensitivity, specificity, PPV and NPV of TCT for detecting esophageal perforation were 100, 54.6, 23.4 and 100%, respectively. When TCT was negative (n = 107), an alternative diagnosis was evident in 65 cases. Thoracic computed tomography (TCT) had 100% sensitivity and negative predictive value for excluding esophageal perforation. FE may be omitted in patients who have no evidence of mediastinal collection, pneumomediastinum or esophageal wall defect on TCT. However, in the presence of any of these features, FE is still necessary to confirm or exclude the presence of an esophageal perforation.

  1. Diagnostic performance of in vivo 3-T MRI for articular cartilage abnormalities in human osteoarthritic knees using histology as standard of reference

    Energy Technology Data Exchange (ETDEWEB)

    Saadat, Ehsan [University of California San Francisco, School of Medicine and Department of Radiology, San Francisco, CA (United States); Jobke, Bjoern; Chu, Bill; Lu, Ying; Cheng, Jonathan; Li, Xiaojuan; Majumdar, Sharmila; Link, Thomas M. [University of California San Francisco, Department of Radiology, San Francisco, CA (United States); Ries, Michael D. [University of California San Francisco, Department of Orthopaedic Surgery, San Francisco, CA (United States)

    2008-10-15

    The purpose of this study was (1) to evaluate the sensitivity, specificity and accuracy of sagittal in vivo 3-T intermediate-weighted fast spin-echo (iwFSE) sequences in the assessment of knee cartilage pathologies using histology as the reference standard in patients undergoing total knee replacement, and (2) to correlate MR imaging findings typically associated with osteoarthritis such as bone marrow edema pattern (BMEP) and cartilage swelling with histological findings. Tibial plateaus and femoral condyles of eight knees of seven patients were resected during surgery, and sagittal histological sections were prepared for histology. Preoperative MRI findings were compared to the corresponding region in histological sections for thickness, surface integrity and signal pattern of cartilage, and histological findings in areas of BMEP and swelling were documented. The overall sensitivity, specificity and accuracy were 72%, 69% and 70% for thickness, 69%, 74% and 73% for surface and 36%, 62% and 45% for intracartilaginous signal pattern. For all cases of BMEP on MRI subchondral ingrowth of fibrovascular tissue and increased bone remodeling were observed. MRI using fat-saturated iwFSE sequences showed good performance in assessing cartilage thickness and surface lesions, while signal changes of cartilage were not suited to characterize the severity of cartilage degeneration as validated by histology. (orig.)

  2. Simultaneous determination of four active components in Alisma orientale (Sam. Juz. by HPLC–DAD using a single reference standard

    Directory of Open Access Journals (Sweden)

    Yao-Wen Zhang

    2015-04-01

    Full Text Available A rapid, simple and practical high-performance liquid chromatography method coupled with diode array detector (HPLC–DAD was developed to evaluate the quality of Alisma orientale (Sam. Juz. through a simultaneous determination of four major active triterpenes using a single standard to determine the multi-components (SSDMCs. Alisol B 23-acetate was selected as the reference compound for calculating the relative response factors. All calibration curves showed good linearity (R2>0.9998 within test ranges. RSDs for intra- and inter-day of four analytes were less than 3.6% and 2.3%; the overall recovery was 92.1–110.2% (SSDMC. The proposed method was successfully applied to quantify the four components in 20 samples from different localities in China. Moreover, significant variations were demonstrated in the content of these compounds. In addition, hierarchical clustering analysis (HCA and principal components analysis (PCA were performed to differentiate and classify the samples based on the contents of Alisol C 23-acetate, Alisol A, Alisol A 24-acetate and Alisol B 23-acetate. This simple, rapid, low-cost and reliable HPLC–DAD method using SSDMC is suitable for routine quantitative analysis and quality control of A. orientale (Sam. Juz. Keywords: SSDMC, Alisma orientale (Sam. Juz, Quality control, HCA, PCA

  3. Quality of claims, references and the presentation of risk results in medical journal advertising: a comparative study in Australia, Malaysia and the United States.

    Science.gov (United States)

    Othman, Noordin; Vitry, Agnes I; Roughead, Elizabeth E

    2010-05-29

    Journal advertising is used by pharmaceutical companies to disseminate medicine information to doctors. The quality of claims, references and the presentation of risk results in Australia and the US has been questioned in several studies. No recent evidence is available on the quality of claims, references and the presentation of risk results in journal advertising in Australia and the US and no Malaysian data have been published. The aim of this study was to compare the quality of claims, references and the presentation of risk results in journal advertising in these three countries. A consecutive sample of 85 unique advertisements from each country was selected from journal advertising published between January 2004 to December 2006. Claims, references and the presentation of risk results in medical journal advertising were compared between the three countries. Less than one-third of the claims were unambiguous claims (Australia, 30%, Malaysia 17%, US, 23%). In Malaysia significantly less unambiguous claims were provided than in Australia and the US (P review or meta-analysis (Australia, 84%, Malaysia, 81%, US, 76%) with journal articles being the most commonly cited references in all countries. Data on file were significantly more likely to be cited in the US (17%) than in Australia (2%) and Malaysia (4%) (P countries. Evidence from a randomized controlled trial, systematic review or meta- analysis was commonly cited to support claims. However, the more frequent use of data that have not been published and independently reviewed in the US compared to Australia and Malaysia raises questions on the quality of references in the US. The use of relative rather than absolute benefits may overemphasize the benefit of medicines which may leave doctors susceptible to misinterpreting information.

  4. Preliminary results on 3D channel modeling: From theory to standardization

    KAUST Repository

    Kammoun, Abla

    2014-06-01

    Three dimensional (3D) beamforming (also elevation beamforming) is now gaining interest among researchers in wireless communication. The reason can be attributed to its potential for enabling a variety of strategies such as sector or user specific elevation beamforming and cell-splitting. Since these techniques cannot be directly supported by current LTE releases, the 3GPP is now working on defining the required technical specifications. In particular, a large effort is currently being made to get accurate 3D channel models that support the elevation dimension. This step is necessary as it will evaluate the potential of 3D and full dimensional (FD) beamforming techniques to benefit from the richness of real channels. This work aims at presenting the on-going 3GPP study item \\'study on 3D-channel model for elevation beamforming and FD-MIMO studies for LTE\\' and positioning it with respect to previous standardization works. © 2014 IEEE.

  5. Preliminary results on 3D channel modeling: From theory to standardization

    KAUST Repository

    Kammoun, Abla; Khanfir, Hajer; Altman, Zwi; Debbah, Mé roú ane; Kamoun, Mohamed Amine

    2014-01-01

    Three dimensional (3D) beamforming (also elevation beamforming) is now gaining interest among researchers in wireless communication. The reason can be attributed to its potential for enabling a variety of strategies such as sector or user specific elevation beamforming and cell-splitting. Since these techniques cannot be directly supported by current LTE releases, the 3GPP is now working on defining the required technical specifications. In particular, a large effort is currently being made to get accurate 3D channel models that support the elevation dimension. This step is necessary as it will evaluate the potential of 3D and full dimensional (FD) beamforming techniques to benefit from the richness of real channels. This work aims at presenting the on-going 3GPP study item 'study on 3D-channel model for elevation beamforming and FD-MIMO studies for LTE' and positioning it with respect to previous standardization works. © 2014 IEEE.

  6. Mejora de la calidad de las medidas de ozono mediante un fotómetro UV de referencia Improvement of the quality of the ozone measurements by means of a standard reference photometer

    Directory of Open Access Journals (Sweden)

    R. Fernández Patier

    2001-11-01

    to implant a NIST UV reference photometer as ozone national standard.Taking into account the procedures used by EPA and NIST, a verification procedure has been developed consistent in the realization of 6 comparisons of the Transfer Standard versus NIST UV reference photometer in different days; at least 5 different ozone concentrations are analyzed. Each comparison begins and ends always with a concentration of 0 ppb of O3, and from each comparison its regression linear is obtained.Once the 6 comparisons are done, the calibration relationship is obtained and the uncertainty associated with the transfer standard is calculated.Until now, the verifications of 17 transfer standards have been done: 11 of them were UV photometers, 2 were ozone generators and 4 were ozone generators of dilution banks.From the results is concluded that generally the uncertainties of the ozone generators are greater than those of the UV photometers, so being recommended this one like transfer standard.To emphasize that with the utilization of the tranfer standards for the calibration of ozone analyzers, the quality and the trazability of the generated data are guaranteed.

  7. First Results from the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Stephanie

    2009-01-01

    Considerable effort in the astronomy education research over the past several years has focused on developing assessment tools in the form of multiple-choice conceptual diagnostics and content knowledge surveys. This has been critically important in advancing astronomy as a sub-discipline of physics education research, allowing researchers to establish the initial knowledge state of students as well as to attempt to measure some of the impacts of innovative instructional interventions. Before now, few of the existing instruments were constructed upon a solid list of clearly articulated and widely agreed upon learning objectives. Moving beyond the 10-year old Astronomy Diagnostics Test, we have developed and validated a new assessment instrument that is tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. Researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science and Math Teaching Center (UWYO SMTC) designed a criterion-referenced assessment tool, called the Test Of Astronomy STandards (TOAST). Through iterative development, this multiple-choice instrument has a high degree of reliability and validity for instructors and researchers needing information on students’ initial knowledge state at the beginning of a course and can be used, in aggregate, to help measure the impact of course-length duration instructional strategies for undergraduate science survey courses with learning goals tightly aligned to the consensus goals of the astronomy education community.

  8. Profile of osteopathic practice in Spain: results from a standardized data collection study.

    Science.gov (United States)

    Alvarez Bustins, Gerard; López Plaza, Pedro-Victor; Carvajal, Sonia Roura

    2018-04-11

    There is limited research regarding patients' profiles and consumer attitudes and habits of osteopathy in Spain. The purpose of this study was to profile patients who regularly receive osteopathic care in Spain using an internationally developed standardized data collection tool. During the period between April 2014 and December 2015, a UK-developed standardized data collection tool was distributed to Spanish osteopaths who voluntarily agreed to participate in this cross-sectional study. Thirty-six osteopaths participated in this study and returned a total of 314 completed datasets. Of 314 patients, 61% were women and 39% were men, with a mean age of 40 years (SD 17.02 years, range 0 to 83 years). Forty-four percent were full-time salaried workers, and in 78% of cases, receiving osteopathic treatment was the patient's own choice. Chronic spinal pain presentations were the most frequent reasons for consultation. Seventy-five percent of patients presented with a coexisting condition, mainly gastrointestinal disorders and headaches. The main treatment approach consisted of mobilization techniques, followed by soft tissue, cranial and high velocity thrust techniques. Improvement or resolution of the complaint was experienced by 93% of patients after a small number of sessions. Adverse events were minor and occurred in 7% of all cases. This is the first study carried out in Spain analyzing the profile of patients who receive osteopathic care. The typical patient who receives osteopathic care in Spain is middle-aged, presents mainly with chronic spinal pain, and voluntarily seeks osteopathic treatment. Osteopathic treatment produces a significant improvement in the majority of cases with a low rate of minor adverse events reported.

  9. Non-proliferation through effective international control, with particular reference to peaceful uses of nuclear material as a result of nuclear disarmament and international control of plutonium

    International Nuclear Information System (INIS)

    Imai, Ryukichi

    1993-01-01

    The role of nuclear factors in the international political situation has changed. The emphasis is now on the new circumstance of the post cold-war world. Non-proliferation is dealt with through effective international control, with particular reference to peaceful uses of nuclear material as a result of nuclear weapons dismantling and international control of plutonium

  10. Reference standards to assess physical fitness of children and adolescents of Brazil: an approach to the students of the Lake Itaipú region—Brazil

    Directory of Open Access Journals (Sweden)

    Edilson Hobold

    2017-11-01

    Full Text Available Background The importance of assessing body fat variables and physical fitness tests plays an important role in monitoring the level of activity and physical fitness of the general population. The objective of this study was to develop reference norms to evaluate the physical fitness aptitudes of children and adolescents based on age and sex from the lake region of Itaipú, Brazil. Methods A descriptive cross-sectional study was carried out with 5,962 students (2,938 males and 3,024 females with an age range of 6.0 and 17.9 years. Weight (kg, height (cm, and triceps (mm, and sub-scapular skinfolds (mm were measured. Body Mass Index (BMI kg/m2 was calculated. To evaluate the four physical fitness aptitude dimensions (morphological, muscular strength, flexibility, and cardio-respiratory, the following physical education tests were given to the students: sit-and-reach (cm, push-ups (rep, standing long jump (cm, and 20-m shuttle run (m. Results and Discussion Females showed greater flexibility in the sit-and-reach test and greater body fat than the males. No differences were found in BMI. Percentiles were created for the four components for the physical fitness aptitudes, BMI, and skinfolds by using the LMS method based on age and sex. The proposed reference values may be used for detecting talents and promoting health in children and adolescents.

  11. Quality of claims, references and the presentation of risk results in medical journal advertising: a comparative study in Australia, Malaysia and the United States

    Directory of Open Access Journals (Sweden)

    Vitry Agnes I

    2010-05-01

    Full Text Available Abstract Background Journal advertising is used by pharmaceutical companies to disseminate medicine information to doctors. The quality of claims, references and the presentation of risk results in Australia and the US has been questioned in several studies. No recent evidence is available on the quality of claims, references and the presentation of risk results in journal advertising in Australia and the US and no Malaysian data have been published. The aim of this study was to compare the quality of claims, references and the presentation of risk results in journal advertising in these three countries. Methods A consecutive sample of 85 unique advertisements from each country was selected from journal advertising published between January 2004 to December 2006. Claims, references and the presentation of risk results in medical journal advertising were compared between the three countries. Results Less than one-third of the claims were unambiguous claims (Australia, 30%, Malaysia 17%, US, 23%. In Malaysia significantly less unambiguous claims were provided than in Australia and the US (P Conclusions The majority of claims were vague suggesting poor quality of claims in journal advertising in these three countries. Evidence from a randomized controlled trial, systematic review or meta- analysis was commonly cited to support claims. However, the more frequent use of data that have not been published and independently reviewed in the US compared to Australia and Malaysia raises questions on the quality of references in the US. The use of relative rather than absolute benefits may overemphasize the benefit of medicines which may leave doctors susceptible to misinterpreting information.

  12. The standardization of 133Ba: international comparison of results (June 1984)

    International Nuclear Information System (INIS)

    Meyer, B.R.

    1985-01-01

    Participation in an international intercomparison of measurements of the activity of a 133 Ba solution is described. The 4π (LS) -γ coincidence extrapolation method was used. Results for two different γ-channels were obtained. A graphical representation of the results obtained by the different participating laboratories is given

  13. Development of a Standardized Approach to Disclosing Amyloid Imaging Research Results in Mild Cognitive Impairment

    OpenAIRE

    Lingler, Jennifer H.; Butters, Meryl A.; Gentry, Amanda L.; Hu, Lu; Hunsaker, Amanda E.; Klunk, William E.; Mattos, Meghan K.; Parker, Lisa A.; Roberts, J. Scott; Schulz, Richard

    2016-01-01

    The increased use of PET amyloid imaging in clinical research has sparked numerous concerns about whether and how to return such research test results to study participants. Chief among these is the question of how best to disclose amyloid imaging research results to individuals who have cognitive symptoms that could impede comprehension of the information conveyed. We systematically developed and evaluated informational materials for use in pre-test counseling and post-test...

  14. Contrast-enhanced computed tomography for the diagnosis of fatty liver: prospective study with same-day biopsy used as the reference standard

    International Nuclear Information System (INIS)

    Kim, Dae Yoon; Park, Seong Ho; Lee, Seung Soo; Kim, Hye Jin; Kim, So Yeon; Kim, Min-Young; Lee, Yedaun; Kim, Tae Kyoung; Khalili, Korosh; Bae, Mi Hyun; Lee, Joo Yeon; Lee, Sung-Gyu; Yu, Eun Sil

    2010-01-01

    Purpose: The study purpose was to prospectively determine the accuracy of contrast-enhanced CT in diagnosing fatty liver using same-day biopsy as the reference standard. One hundred seventy-nine potential living liver donors underwent unenhanced and portal-phase contrast-enhanced hepatic CT and subsequent liver biopsy on the same day. Attenuation difference between the liver and the spleen on unenhanced ( pre L-S) and contrast-enhanced ( post L-S) images and blood-subtracted hepatic attenuation on contrast-enhanced images ( post L-B), calculated by [L - 0.3 x (0.75 x P + 0.25 x A) ]/0.7 where L, P and A represent the attenuation of the liver, main portal vein and abdominal aorta, respectively, were obtained. The accuracy of these indices in diagnosing fatty liver according to various threshold levels, 5%-30% histological steatosis in increments of 5%, was compared using ROC analysis. The area under the ROC curve for pre L-S, post L-S and post L-B was 0.663-0.918, 0.712-0.847 and 0.821-0.923, respectively, depending on the threshold levels of hepatic steatosis. The accuracy of pre L-S and post L-S did not differ (P ≥ 0.054), despite a trend towards a lower accuracy with post L-S. post L-B yielded higher accuracy than pre L-S at threshold levels of 5% and 10% (P ≤ 0.002) and similar accuracy to pre L-S at the other threshold levels (P ≥ 0.144). Portal-phase contrast-enhanced CT has a similar, or even greater, accuracy than unenhanced CT in diagnosing fatty liver. (orig.)

  15. Interpreting Mobile and Handheld Air Sensor Readings in Relation to Air Quality Standards and Health Effect Reference Values: Tackling the Challenges

    Directory of Open Access Journals (Sweden)

    George M. Woodall

    2017-09-01

    Full Text Available The US Environmental Protection Agency (EPA and other federal agencies face a number of challenges in interpreting and reconciling short-duration (seconds to minutes readings from mobile and handheld air sensors with the longer duration averages (hours to days associated with the National Ambient Air Quality Standards (NAAQS for the criteria pollutants-particulate matter (PM, ozone, carbon monoxide, lead, nitrogen oxides, and sulfur oxides. Similar issues are equally relevant to the hazardous air pollutants (HAPs where chemical-specific health effect reference values are the best indicators of exposure limits; values which are often based on a lifetime of continuous exposure. A multi-agency, staff-level Air Sensors Health Group (ASHG was convened in 2013. ASHG represents a multi-institutional collaboration of Federal agencies devoted to discovery and discussion of sensor technologies, interpretation of sensor data, defining the state of sensor-related science across each institution, and provides consultation on how sensors might effectively be used to meet a wide range of research and decision support needs. ASHG focuses on several fronts: improving the understanding of what hand-held sensor technologies may be able to deliver; communicating what hand-held sensor readings can provide to a number of audiences; the challenges of how to integrate data generated by multiple entities using new and unproven technologies; and defining best practices in communicating health-related messages to various audiences. This review summarizes the challenges, successes, and promising tools of those initial ASHG efforts and Federal agency progress on crafting similar products for use with other NAAQS pollutants and the HAPs. NOTE: The opinions expressed are those of the authors and do not necessary represent the opinions of their Federal Agencies or the US Government. Mention of product names does not constitute endorsement.

  16. Contrast-enhanced computed tomography for the diagnosis of fatty liver: prospective study with same-day biopsy used as the reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Yoon; Park, Seong Ho; Lee, Seung Soo; Kim, Hye Jin; Kim, So Yeon; Kim, Min-Young; Lee, Yedaun [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea); Kim, Tae Kyoung; Khalili, Korosh [University of Toronto, Department of Medical Imaging, University Health Network, Toronto, ON (Canada); Bae, Mi Hyun; Lee, Joo Yeon [University of Ulsan College of Medicine, Seoul (Korea); Lee, Sung-Gyu [University of Ulsan College of Medicine, Asan Medical Center, Division of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, Seoul (Korea); Yu, Eun Sil [University of Ulsan College of Medicine, Asan Medical Center, Department of Diagnostic Pathology, Seoul (Korea)

    2010-02-15

    Purpose: The study purpose was to prospectively determine the accuracy of contrast-enhanced CT in diagnosing fatty liver using same-day biopsy as the reference standard. One hundred seventy-nine potential living liver donors underwent unenhanced and portal-phase contrast-enhanced hepatic CT and subsequent liver biopsy on the same day. Attenuation difference between the liver and the spleen on unenhanced ({sub pre} L-S) and contrast-enhanced ({sub post} L-S) images and blood-subtracted hepatic attenuation on contrast-enhanced images ({sub post} L-B), calculated by [L - 0.3 x (0.75 x P + 0.25 x A) ]/0.7 where L, P and A represent the attenuation of the liver, main portal vein and abdominal aorta, respectively, were obtained. The accuracy of these indices in diagnosing fatty liver according to various threshold levels, 5%-30% histological steatosis in increments of 5%, was compared using ROC analysis. The area under the ROC curve for{sub pre} L-S,{sub post} L-S and{sub post} L-B was 0.663-0.918, 0.712-0.847 and 0.821-0.923, respectively, depending on the threshold levels of hepatic steatosis. The accuracy of{sub pre} L-S and{sub post} L-S did not differ (P {>=} 0.054), despite a trend towards a lower accuracy with{sub post} L-S.{sub post} L-B yielded higher accuracy than{sub pre} L-S at threshold levels of 5% and 10% (P {<=} 0.002) and similar accuracy to{sub pre} L-S at the other threshold levels (P {>=} 0.144). Portal-phase contrast-enhanced CT has a similar, or even greater, accuracy than unenhanced CT in diagnosing fatty liver. (orig.)

  17. Serodiagnosis of whooping cough in Belgium: results of the National Reference Centre for Bordetella pertussis anno 2013.

    Science.gov (United States)

    Duterme, Sophie; Vanhoof, Raymond; Vanderpas, Jean; Pierard, Denis; Huygen, Kris

    2016-04-01

    Report on the pitfalls of serodiagnosis of pertussis in Belgium for 2013 by the NRC Bordetella. Determine cases of acute infection using an anti-pertussis toxin (PT) IgG antibody ELISA. A total of 2471 serum samples were received. Clinical information on the duration of cough (at moment of blood sampling) is essential for a reliable interpretation of the results. In order to avoid false negative results, 213 samples for which this information was lacking were not tested. For a total of 2179 patients tested, 520 (23.9%) had antibody levels indicative of an acute infection, 261 (12%) samples were diagnosed as positive (indicative of a pertussis infection or vaccination during the last year), 143 (6.7%) samples were classified as doubtful and 752 (34,5%) (35.5%) were diagnosed as negative. The serodiagnosis of pertussis has limited value for the early diagnosis of the disease and PCR analysis on nasopharyngeal swabs is the method of choice during the first 2 weeks and always for young children pertussis, serum samples should preferentially be collected 3 weeks after onset of symptoms.

  18. 78 FR 34340 - Welded Carbon Steel Standard Pipe and Tube Products From Turkey: Preliminary Results of...

    Science.gov (United States)

    2013-06-07

    ... Pipe and Tube Products From Turkey: Preliminary Results of Antidumping Duty Administrative Review; 2011... tube products (welded pipe and tube) from Turkey.\\2\\ The period of review is May 1, 2011, to April 30... A.S. (BMB) had reviewable sales during this period of review. DATES: As of June 7, 2013. FOR FURTHER...

  19. Development of a Standardized Approach to Disclosing Amyloid Imaging Research Results in Mild Cognitive Impairment.

    Science.gov (United States)

    Lingler, Jennifer H; Butters, Meryl A; Gentry, Amanda L; Hu, Lu; Hunsaker, Amanda E; Klunk, William E; Mattos, Meghan K; Parker, Lisa A; Roberts, J Scott; Schulz, Richard

    2016-03-08

    The increased use of PET amyloid imaging in clinical research has sparked numerous concerns about whether and how to return such research test results to study participants. Chief among these is the question of how best to disclose amyloid imaging research results to individuals who have cognitive symptoms that could impede comprehension of the information conveyed. We systematically developed and evaluated informational materials for use in pre-test counseling and post-test disclosures of amyloid imaging research results in mild cognitive impairment (MCI). Using simulated sessions, persons with MCI and their family care partners (N = 10 dyads) received fictitious but realistic information regarding brain amyloid status, followed by an explanation of how results impact Alzheimer's disease risk. Satisfaction surveys, comprehension assessments, and focus group data were analyzed to evaluate the materials developed. The majority of persons with MCI and their care partners comprehended and were highly satisfied with the information presented. Focus group data reinforced findings of high satisfaction and included 6 recommendations for practice: 1) offer pre-test counseling, 2) use clear graphics, 3) review participants' own brain images during disclosures, 4) offer take-home materials, 5) call participants post-disclosure to address emerging questions, and 6) communicate seamlessly with primary care providers. Further analysis of focus group data revealed that participants understood the limitations of amyloid imaging, but nevertheless viewed the prospect of learning one's amyloid status as valuable and empowering.

  20. SHORT COMMUNICATION: Transportable Zener-diode Voltage Standard

    Science.gov (United States)

    Karpov, O. V.; Shulga, V. M.; Shakirzyanova, F. R.; Sarandi, A. E.

    1994-01-01

    Five transportable Zener-diode dc voltage standards have been developed, fabricated and investigated at the NPO VNIIFTRI. The standards were designed to transfer the unit of electromotive force (emf) from Josephson reference standards to measuring instruments. Following the results of these investigations, standard N 02 has been used for intercomparison of the Russian Josephson reference standards.

  1. Analyses and results from standard surveillance programmes of WWER 440/V-213C reactor pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Falcnik, M; Brumovsky, M; Pav, T [Czech Nuclear Society, Prague (Czech Republic)

    1994-12-31

    In Czech and Slovak republics, six units of WWER 440/C type reactors are monitored by surveillance specimens programmes; the specimens are determined for static tensile testing, impact notch toughness testing and fracture toughness evaluation. Results of mechanical properties of these specimens after irradiation in intervals between 1 and 5 years of operation, are summarized and discussed with respect to the effect of individual heats and welded joints, radiation embrittlement, and annealing recovery. (authors). 3 refs., 11 figs., 2 tabs.

  2. EPA/NMED/LANL 1998 water quality results: Statistical analysis and comparison to regulatory standards

    International Nuclear Information System (INIS)

    Gallaher, B.; Mercier, T.; Black, P.; Mullen, K.

    2000-01-01

    Four governmental agencies conducted a round of groundwater, surface water, and spring water sampling at the Los Alamos National Laboratory during 1998. Samples were split among the four parties and sent to independent analytical laboratories. Results from three of the agencies were available for this study. Comparisons of analytical results that were paired by location and date were made between the various analytical laboratories. The results for over 50 split samples analyzed for inorganic chemicals, metals, and radionuclides were compared. Statistical analyses included non-parametric (sign test and signed-ranks test) and parametric (paired t-test and linear regression) methods. The data pairs were tested for statistically significant differences, defined by an observed significance level, or p-value, less than 0.05. The main conclusion is that the laboratories' performances are similar across most of the analytes that were measured. In some 95% of the laboratory measurements there was agreement on whether contaminant levels exceeded regulatory limits. The most significant differences in performance were noted for the radioactive suite, particularly for gross alpha particle activity and Sr-90

  3. Evaluation of a draft standard on performance specifications for health physics instrumentation. Initial results for radiological tests

    International Nuclear Information System (INIS)

    Swinth, K.L.; Kenoyer, J.L.; Mileham, A.P.; Kathren, R.L.; Selby, J.M.

    1983-06-01

    The draft ANSI standard N42.17D2 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. The primary objective of the project is the evaluation of the applicability and practicality of the proposed standard through testing of a cross-section of currently available commercial instruments to determine how well they conform to the standard. The standard is being tested against instruments such as ionization chambers, G.M. detectors, alpha survey meters, and neutron dose equivalent survey meters. This paper presents results of the preliminary radiological performance tests on ionization chambers and G.M. detectors. This includes both the data generated during the tests and a discussion of procedures developed to perform the testing. Results are reported for response time, accuracy, precision, radiation overloads, and angular dependence. In addition, results are reported for parameters that affect instrument performance including battery lifetime, geotropism and stability. Initial test indicates that some of the instruments will not meet the criteria specified in ANSI N42.17D2. Results cover approximately 40 instruments that have been obtained by direct purchase, by loan from instrument vendors or by loan from others including DOE licensees

  4. Factors That Influence Standard Automated Perimetry Test Results in Glaucoma : Test Reliability, Technician Experience, Time of Day, and Season

    NARCIS (Netherlands)

    Montolio, Francisco G. Junoy; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M.

    2012-01-01

    PURPOSE. To determine the influence of several factors on standard automated perimetry test results in glaucoma. METHODS. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience,

  5. Factors that influence standard automated perimetry test results in glaucoma: Test reliability, technician experience, time of day, and season

    NARCIS (Netherlands)

    F.G.J. Montolio (Francisco G. Junoy); C. Wesselink (Christiaan); M.C.M. Gordijn (Marijke); N.M. Jansonius (Nomdo)

    2012-01-01

    textabstractPURPOSE. To determine the influence of several factors on standard automated perimetry test results in glaucoma. METHODS. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician

  6. STL pocket reference

    CERN Document Server

    Lischner, Ray

    2003-01-01

    The STL Pocket Reference describes the functions, classes, and templates in that part of the C++ standard library often referred to as the Standard Template Library (STL). The STL encompasses containers, iterators, algorithms, and function objects, which collectively represent one of the most important and widely used subsets of standard library functionality. The C++ standard library, even the subset known as the STL, is vast. It's next to impossible to work with the STL without some sort of reference at your side to remind you of template parameters, function invocations, return types--ind

  7. Standardized evaluation of tumor-infiltrating lymphocytes in breast cancer: results of the ring studies of the international immuno-oncology biomarker working group.

    Science.gov (United States)

    Denkert, Carsten; Wienert, Stephan; Poterie, Audrey; Loibl, Sibylle; Budczies, Jan; Badve, Sunil; Bago-Horvath, Zsuzsanna; Bane, Anita; Bedri, Shahinaz; Brock, Jane; Chmielik, Ewa; Christgen, Matthias; Colpaert, Cecile; Demaria, Sandra; Van den Eynden, Gert; Floris, Giuseppe; Fox, Stephen B; Gao, Dongxia; Ingold Heppner, Barbara; Kim, S Rim; Kos, Zuzana; Kreipe, Hans H; Lakhani, Sunil R; Penault-Llorca, Frederique; Pruneri, Giancarlo; Radosevic-Robin, Nina; Rimm, David L; Schnitt, Stuart J; Sinn, Bruno V; Sinn, Peter; Sirtaine, Nicolas; O'Toole, Sandra A; Viale, Giuseppe; Van de Vijver, Koen; de Wind, Roland; von Minckwitz, Gunter; Klauschen, Frederick; Untch, Michael; Fasching, Peter A; Reimer, Toralf; Willard-Gallo, Karen; Michiels, Stefan; Loi, Sherene; Salgado, Roberto

    2016-10-01

    Multiple independent studies have shown that tumor-infiltrating lymphocytes (TIL) are prognostic in breast cancer with potential relevance for response to immune-checkpoint inhibitor therapy. Although many groups are currently evaluating TIL, there is no standardized system for diagnostic applications. This study reports the results of two ring studies investigating TIL conducted by the International Working Group on Immuno-oncology Biomarkers. The study aim was to determine the intraclass correlation coefficient (ICC) for evaluation of TIL by different pathologists. A total of 120 slides were evaluated by a large group of pathologists with a web-based system in ring study 1 and a more advanced software-system in ring study 2 that included an integrated feedback with standardized reference images. The predefined aim for successful ring studies 1 and 2 was an ICC above 0.7 (lower limit of 95% confidence interval (CI)). In ring study 1 the prespecified endpoint was not reached (ICC: 0.70; 95% CI: 0.62-0.78). On the basis of an analysis of sources of variation, we developed a more advanced digital image evaluation system for ring study 2, which improved the ICC to 0.89 (95% CI: 0.85-0.92). The Fleiss' kappa value for international standardization project shows that reproducible evaluation of TIL is feasible in breast cancer. This opens the way for standardized reporting of tumor immunological parameters in clinical studies and diagnostic practice. The software-guided image evaluation approach used in ring study 2 may be of value as a tool for evaluation of TIL in clinical trials and diagnostic practice. The experience gained from this approach might be applicable to the standardization of other diagnostic parameters in histopathology.

  8. Labeling programs and efficiency standards to control the energy consumption of household appliances: current situation, main results and recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Menanteau, Ph.

    2000-09-01

    To control the rise in electricity consumption for specific uses, the industrialized countries started by introducing special programs aimed at improving energy efficiency. Among the different instruments available, labeling programs and minimum energy performance standards (MEPS) have proved to be very effective. The first part of this document presents the current situation, the main results and recommendations concerning the labeling programs and efficiency standards to control the energy consumption of household appliances. This analyze is done for each country in details providing the name of the program or measure, the date of implementation, the objective and the main characteristics of the program, the impacts and evaluation. (A.L.B.)

  9. Tracking LHC Models with Thick Lens Quadrupoles: Results and Comparisons with the Standard Thin Lens tracking.

    CERN Document Server

    Burkhardt, H; Risselada, T

    2012-01-01

    So far, the massive numerical simulation studies of the LHC dynamic aperture were performed using thin lens models of the machine. This approach has the clear advantage of speed, but it has also the disadvantage of requiring re-matching of the optics from the real thick configuration to the thin one. The figure-of-merit for the re-matching is the agreement between the beta-functions for the two models. However, the quadrupole gradients are left as free parameters, thus, the impact of the magnetic multipoles might be affected by this approach. In turns, the dynamic aperture computation could be changed. In this paper the new approach is described and the results for the dynamic aperture are compared with the old approach, including detailed considerations on the CPU-time requirements.

  10. The value of Standards and Labelling: an international cost-benefit analysis tool for Standards and Labelling programs with results for Central American countries

    International Nuclear Information System (INIS)

    Buskirk, Robert D. Van; McNeil, Michael A.; Letschert, Virginie E.

    2005-01-01

    We describe a cost-benefit spreadsheet analysis tool that provides an evaluation of the net impacts of an appliance standards and labelling (SandL) program. The tool is designed to provide a rough estimate at very low cost to local analysts, while allowing for a more accurate evaluation when detailed local data are available. The methodology takes a bottom-up engineering approach, beginning with appliance-specific engineering parameters relating efficiency improvement and incremental costs associated with specific design technologies. Efficiency improvement afforded by each potential policy option is combined with local appliance use patterns to estimate average annual energy consumption for each appliance. This information is combined with appliance lifetime data and local energy prices to provide a life cycle cost impact assessment at the household level. In addition to household level impacts, the analysis tool forecasts future appliance sales, in order to calculate potential energy savings, consumer financial impacts and carbon emissions reductions at the national level. In order to demonstrate the features of the policy model employed, this poster presents a regional analysis based on the most recent publicly available appliance data. In particular, a set of developing countries in Central America were chosen as an example. Taken as a whole, the Central American results demonstrate the general level of benefit which could be afforded in these countries. Comparison between the countries reveals the key parameters determining the benefit a given country can expect from a standards program

  11. Results of SFD experiment CORA-13 (OECD International Standard Problem 31)

    International Nuclear Information System (INIS)

    Hagen, S.; Hofmann, P.; Noack, V.; Schanz, G.; Schumacher, G.; Sepold, L.

    1993-02-01

    The PWR-type assemblies usually consist of 25 rods with 16 electrically heated fuel rod simulators and nine unheated rods (full-pellet and absorber rods). Bundle CORA-13, a PWR-type assembly, contained two Ag/In/Cd - steel absorber rods. The test bundle was subjected to temperature transients of a slow heatup rate in a steam environment with a temperature ramp rate of 1 K/s. The temperature escalation due to the exothermal zircaloy(Zry)-steam reaction started at about 1100 C at an elevation of 850 mm (1000 s after onset of the transient), leading to a temperature plateau of 1850 C and after initiation of quenching to maximum temperatures of approximately 2000 C to 2300 C. CORA-13 was terminated by quenching with water from the bottom with a flooding rate of 1 cm/s. Rod destruction started with the failure of the absorber rod cladding at about 1200 C, i.e. about 250 K below the melting regime of steel. Penetration of the steel cladding was presumably caused by a eutectic interaction between steel and the zircaloy guide tube. As a consequence, the absorber-steel-zircaloy melt relocated radially outward and axially downward. Besides this melt relocation the test bundle experienced severe oxidation and partial melting of the cladding, fuel dissolution by Zry/UO 2 interaction, complete Inconel grid spacer destruction, and relocation of melts and fragments to lower elevations in the bundle. An extended flow blockage has formed at the axial midplane. Quenching by water resulted, besides additional fragmentation of fuel rods and shroud, in an additional temperature increase in the upper bundle region. Coinciding with the temperature response an additional hydrogen buildup was detected. During the flooding phase 48% of the total hydrogen were generated. (orig./HP) [de

  12. ValidatorDB: database of up-to-date validation results for ligands and non-standard residues from the Protein Data Bank.

    Science.gov (United States)

    Sehnal, David; Svobodová Vařeková, Radka; Pravda, Lukáš; Ionescu, Crina-Maria; Geidl, Stanislav; Horský, Vladimír; Jaiswal, Deepti; Wimmerová, Michaela; Koča, Jaroslav

    2015-01-01

    Following the discovery of serious errors in the structure of biomacromolecules, structure validation has become a key topic of research, especially for ligands and non-standard residues. ValidatorDB (freely available at http://ncbr.muni.cz/ValidatorDB) offers a new step in this direction, in the form of a database of validation results for all ligands and non-standard residues from the Protein Data Bank (all molecules with seven or more heavy atoms). Model molecules from the wwPDB Chemical Component Dictionary are used as reference during validation. ValidatorDB covers the main aspects of validation of annotation, and additionally introduces several useful validation analyses. The most significant is the classification of chirality errors, allowing the user to distinguish between serious issues and minor inconsistencies. Other such analyses are able to report, for example, completely erroneous ligands, alternate conformations or complete identity with the model molecules. All results are systematically classified into categories, and statistical evaluations are performed. In addition to detailed validation reports for each molecule, ValidatorDB provides summaries of the validation results for the entire PDB, for sets of molecules sharing the same annotation (three-letter code) or the same PDB entry, and for user-defined selections of annotations or PDB entries. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  13. Elaboration of standards referred to human exposure to electromagnetic fields in the range of 9kHz to 300GHz in the National System of Health, Brazil

    International Nuclear Information System (INIS)

    Souza, Joao Henrique Campos de; Giacomet, Andrea Fatima; Cunha, Tarcisio; Drumond, Ivens; Sa, Fabiana O.; Mendes, Paula

    2005-01-01

    The Portaria of the Ministry of Health no. 279 (Ordinance 279), of February 22, 2005, establishes a Working Group-GT with the purpose to elaborate standards relating to human exposure to electromagnetic fields in the range of 9 kHz to 300 GHz in the Sistema Unico de Saude (National System of Health), Brazil. Since then, we have conducted several studies on the biological effects of radiation exposure in this spectral range. The GT proposes the use of the geographical instruments coupled information systems to define an alternative pattern of surveillance, based on the determination of Areas of Risks. Each source of electromagnetic radiation is associated with territorial boundaries that surround it using progressively larger distances, thus determining areas of influence whose intensity is attenuated as the distance to the source increases. This paper presents the main results obtained by the Working Group

  14. International reference reagents: antihuman globulin. An ISBT/ICSH joint working party report. International Society of Blood Transfusion. International Committee for Standardization in Haematology.

    Science.gov (United States)

    Case, J; Ford, D S; Chung, A; Collins, R; Kochman, S; Mazda, T; Overbeeke, M; Perera, R; Sakuldamrongpanich, T; Scott, M; Voak, D; Zupańska, B

    1999-01-01

    An international working party has conducted a study designed to select a suitable reference reagent for antihuman globulin, to replace those first made available in 1987. The chosen preparation contains levels of anti-IgG and anti-C3 (anti-C3c and anti-C3d) potency that are considered suitable to serve for reference when evaluating either polyspecific antihuman globulin reagents or those containing their separate monospecific components. The reference material is available in 2-ml freeze-dried aliquots from seven assigned distribution centres.

  15. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE), Version 5.0: Models and Results Database (MAR-D) reference manual. Volume 8

    International Nuclear Information System (INIS)

    Russell, K.D.; Skinner, N.L.

    1994-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. The primary function of MAR-D is to create a data repository for completed PRAs and Individual Plant Examinations (IPEs) by providing input, conversion, and output capabilities for data used by IRRAS, SARA, SETS, and FRANTIC software. As probabilistic risk assessments and individual plant examinations are submitted to the NRC for review, MAR-D can be used to convert the models and results from the study for use with IRRAS and SARA. Then, these data can be easily accessed by future studies and will be in a form that will enhance the analysis process. This reference manual provides an overview of the functions available within MAR-D and step-by-step operating instructions

  16. The International Atomic Energy Agency circulation of laboratory air standards for stable isotope comparisons: Aims, preparation and preliminary results

    International Nuclear Information System (INIS)

    Allison, C.E.; Francey, R.J.; Steele, L.P.

    2002-01-01

    Ten air standards in high-pressure aluminium cylinders were prepared, covering a specified range of CO 2 concentration and δ 13 C and δ 18O isotopic composition, to be used for laboratory intercomparisons with the primary aim of merging global atmospheric CO 2 δ 13 C data sets. After establishing the stability of the standards, five were circulated between four laboratories with established high precision global monitoring networks to quantify differences between the measurement scales used in the laboratories. Measurements of CO 2 concentration in three of the four laboratories showed agreement to better than 0.2 ppm for the five standards. Measurements of N 2 O concentration reported by three of the laboratories agreed to better than 3 ppb after correction for known scaling factor differences, but a fourth laboratory reported results for two cylinders lower by about 20 ppb, contributing a δ 13 C uncertainty of about 0.012 per mille for these two cylinders. The reported measurements of the δ 13 C and δ 18O of CO 2 extracted from the air in the five standards showed large offsets between the laboratories of up to 0.1 per mille in δ 13 C and up to 1 per mille in δ 18O . Analysis of the results shows that about 40% of the offsets arises from differences in the procedures used in each laboratory to calculate the δ 13 C and δ 18 O values from the raw measurements and that the remainder arises from the pre-concentration step. Using one of the circulated standards to 'normalise' the others removes most of the inter-laboratory differences but there remains a non-linear response in one or more laboratories. The differences in δ 13 C that remain after normalisation are larger than the target precision of 0.01 per mille. (author)

  17. Standardization of clinical enzyme analysis using frozen human serum pools with values assigned by the International Federation of Clinical Chemistry and Laboratory Medicine reference measurement procedures.

    Science.gov (United States)

    Tong, Qing; Chen, Baorong; Zhang, Rui; Zuo, Chang

    Variation in clinical enzyme analysis, particularly across different measuring systems and laboratories, represents a critical but long-lasting problem in diagnosis. Calibrators with traceability and commutability are imminently needed to harmonize analysis in laboratory medicine. Fresh frozen human serum pools were assigned values for alanine aminotransferase (ALT), aspartate aminotransferase (AST), gamma-glutamyltransferase (GGT), creatine kinase (CK) and lactate dehydrogenase (LDH) by six laboratories with established International Federation of Clinical Chemistry and Laboratory Medicine reference measurement procedures. These serum pools were then used across 76 laboratories as a calibrator in the analysis of five enzymes. Bias and imprecision in the measurement of the five enzymes tested were significantly reduced by using the value-assigned serum in analytical systems with open and single-point calibration. The median (interquartile range) of the relative biases of ALT, AST, GGT, CK and LDH were 2.0% (0.6-3.4%), 0.8% (-0.8-2.3%), 1.0% (-0.5-2.0%), 0.2% (-0.3-1.0%) and 0.2% (-0.9-1.1%), respectively. Before calibration, the interlaboratory coefficients of variation (CVs) in the analysis of patient serum samples were 8.0-8.2%, 7.3-8.5%, 8.1-8.7%, 5.1-5.9% and 5.8-6.4% for ALT, AST, GGT, CK and LDH, respectively; after calibration, the CVs decreased to 2.7-3.3%, 3.0-3.6%, 1.6-2.1%, 1.8-1.9% and 3.3-3.5%, respectively. The results suggest that the use of fresh frozen serum pools significantly improved the comparability of test results in analytical systems with open and single-point calibration.

  18. USGS42 and USGS43: Human-hair stable hydrogen and oxygen isotopic reference materials and analytical methods for forensic science and implications for published measurement results

    Science.gov (United States)

    Coplen, T.B.; Qi, H.

    2012-01-01

    Because there are no internationally distributed stable hydrogen and oxygen isotopic reference materials of human hair, the U.S. Geological Survey (USGS) has prepared two such materials, USGS42 and USGS43. These reference materials span values commonly encountered in human hair stable isotope analysis and are isotopically homogeneous at sample sizes larger than 0.2 mg. USGS42 and USGS43 human-hair isotopic reference materials are intended for calibration of δ(2)H and δ(18)O measurements of unknown human hair by quantifying (1) drift with time, (2) mass-dependent isotopic fractionation, and (3) isotope-ratio-scale contraction. While they are intended for measurements of the stable isotopes of hydrogen and oxygen, they also are suitable for measurements of the stable isotopes of carbon, nitrogen, and sulfur in human and mammalian hair. Preliminary isotopic compositions of the non-exchangeable fractions of these materials are USGS42(Tibetan hair)δ(2)H(VSMOW-SLAP) = -78.5 ± 2.3‰ (n = 62) and δ(18)O(VSMOW-SLAP) = +8.56 ± 0.10‰ (n = 18) USGS42(Indian hair)δ(2)H(VSMOW-SLAP) = -50.3 ± 2.8‰ (n = 64) and δ(18)O(VSMOW-SLAP) = +14.11 ± 0.10‰ (n = 18). Using recommended analytical protocols presented herein for δ(2)H(VSMOW-SLAP) and δ(18)O(VSMOW-SLAP) measurements, the least squares fit regression of 11 human hair reference materials is δ(2)H(VSMOW-SLAP) = 6.085δ(2)O(VSMOW-SLAP) - 136.0‰ with an R-square value of 0.95. The δ(2)H difference between the calibrated results of human hair in this investigation and a commonly accepted human-hair relationship is a remarkable 34‰. It is critical that readers pay attention to the δ(2)H(VSMOW-SLAP) and δ(18)O(VSMOW-SLAP) of isotopic reference materials in publications, and they need to adjust the δ(2)H(VSMOW-SLAP) and δ(18)O(VSMOW-SLAP) measurement results of human hair in previous publications, as needed, to ensure all results on are on the same scales.

  19. Result

    Indian Academy of Sciences (India)

    With reference to the detailed evaluation of bids submitted the following agencies has been selected to award the contract on L1 ( lowest bidder) basis. 1. M/s . CITO INFOTECH, Bengaluru ( for procurement of desktop computers). 2. M/s. MCCANNINFO SOLUTION, Mumbai ( for procurement of laptops computers)

  20. Estimating prevalence and diagnostic test characteristics of bovine cysticercosis in Belgium in the absence of a 'gold standard' reference test using a Bayesian approach.

    Science.gov (United States)

    Jansen, Famke; Dorny, Pierre; Gabriël, Sarah; Eichenberger, Ramon Marc; Berkvens, Dirk

    2018-04-30

    A Bayesian model was developed to estimate values for the prevalence and diagnostic test characteristics of bovine cysticercosis (Taenia saginata) by combining results of four imperfect tests. Samples of 612 bovine carcases that were found negative for cysticercosis during routine meat inspection collected at three Belgian slaughterhouses, underwent enhanced meat inspection (additional incisions in the heart), dissection of the predilection sites, B158/B60 Ag-ELISA and ES Ab-ELISA. This Bayesian approach allows for the combination of prior expert opinion with experimental data to estimate the true prevalence of bovine cysticercosis in the absence of a gold standard test. A first model (based on a multinomial distribution and including all possible interactions between the individual tests) required estimation of 31 parameters, while only allowing for 15 parameters to be estimated. Including prior expert information about specificity and sensitivity resulted in an optimal model with a reduction of the number of parameters to be estimated to 8. The estimated bovine cysticercosis prevalence was 33.9% (95% credibility interval: 27.7-44.4%), while apparent prevalence based on meat inspection is only 0.23%. The test performances were estimated as follows (sensitivity (Se) - specificity (Sp)): enhanced meat inspection (Se 2.87% - Sp 100%), dissection of predilection sites (Se 69.8% - Sp 100%), Ag-ELISA (Se 26.9% - Sp 99.4%), Ab-ELISA (Se 13.8% - Sp 92.9%). Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Calibration of surface roughness standards

    DEFF Research Database (Denmark)

    Thalmann, R.; Nicolet, A.; Meli, F.

    2016-01-01

    organisations. Five surface texture standards of different type were circulated and on each of the standards several roughness parameters according to the standard ISO 4287 had to be determined. 32 out of 395 individual results were not consistent with the reference value. After some corrective actions...

  2. The dosimetric standards for low and medium energy X-rays; Les references dosimetriques pour les rayons X de basses et moyennes energies

    Energy Technology Data Exchange (ETDEWEB)

    Ksouri, W.; Denoziere, M.; Lecerf, N.; Leroy, E.

    2009-07-01

    The Laboratoire national Henri Becquerel (LNE-LNHB) has developed national dosimetric standards for x-rays of low and medium energies. This article describes these standards which are aimed at applications of radiation protection of workers and patients in the fields of medical diagnosis and industrial x-ray radiation. Developments for contact radiotherapy are also discussed. (author)

  3. Verification Results of Safety-grade Optical Modem for Core Protection Calculator (CPC) in Korea Standard Nuclear Power Plant (KSNP)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jangyeol; Son, Kwangseop; Lee, Youngjun; Cheon, Sewoo; Cha, Kyoungho; Lee, Jangsoo; Kwon, Keechoon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    We confirmed that the coverage criteria for a safety-grade optical modem of a Core Protection Calculator is satisfactory using a traceability analysis matrix between high-level requirements and lower-level system test case data set. This paper describes the test environment, test components and items, a traceability analysis, and system tests as a result of system verification and validation based on Software Requirement Specifications (SRS) for a safety-grade optical modem of a Core Protection Calculator (CPC) in a Korea Standard Nuclear Power Plant (KSNP), and Software Design Specifications (SDS) for a safety-grade optical modem of a CPC in a KSNP. All tests were performed according to the test plan and test procedures. Functional testing, performance testing, event testing, and scenario based testing for a safety-grade optical modem of a Core Protection Calculator in a Korea Standard Nuclear Power Plant as a thirty-party verifier were successfully performed.

  4. Results from a Community-Wide Pilot Program to Standardize COPD Education for Patients Across Healthcare Settings in Rhode Island.

    Science.gov (United States)

    Pelland, Kimberly; Youssef, Rouba; Calandra, Kathleen; Cellar, Jennifer; Thiesen, Jennifer; Gardner, Rebekah

    2017-07-05

    Chronic obstructive pulmonary disease (COPD) is associated with significant morbidity, decreased quality of life, and burdensome hospital admissions. Therefore, patients with COPD interact with clinicians in a number of healthcare settings. A coalition of healthcare practitioners in Rhode Island, in partnership with the local Quality Improvement Organization, designed and implemented a standardized, COPD education program for use across multiple healthcare settings. More than 60 organizations participated, producing 140 Master Trainers, who trained 634 staff members at their facilities from October 2015 through June 2016. Master Trainers were satisfied with the training, and we observed significant increases in knowledge scores post-training among all participants, which remained significant when stratified by setting. These results demonstrate that implementation of a community-based program to disseminate patient-centered, standardized COPD education in multiple healthcare settings is feasible. We hope this program will ultimately improve patient outcomes and serve as the foundation for expanding standardized education for other chronic conditions. [Full article available at http://rimed.org/rimedicaljournal-2017-07.asp].

  5. TU-D-201-03: Results of a Survey On the Implementation of the TG-51 Protocol and Associated Addendum On Reference Dosimetry of External Beams

    Energy Technology Data Exchange (ETDEWEB)

    Kim, G [University of California, San Diego, La Jolla, CA (United States); Muir, B [National Research Council, Ottawa, AB (Canada); Culberson, W [University of Wisconsin Madison, Madison, WI (United States); Davis, S [McGill University Health Center, Montreal, QC (Canada); Huang, Y [Henry Ford Health System, West Bloomfield, MI (United States); Lee, S [University of Maryland School of Medicine, Columbia, MD (United States); Lowenstein, J [UT MD Anderson Cancer Center, Houston, TX (United States); Sarfehnia, A [Sunnybrook Health Science Center, Toronto, ON (Canada); Tolani, N [Michael E. DeBakey VA Medical Center, Sugarland (United States); Siebers, J [University of Virginia Health System, Charlottesville, VA (United States)

    2016-06-15

    Purpose: The working group on the review and extension of the TG-51 protocol (WGTG51) collected data from American Association of Physicists in Medicine (AAPM) members with respect to their current TG-51 and associated addendum usage in the interest of considering future protocol addenda and guidance on reference dosimetry best practices. This study reports an overview of this survey on dosimetry of external beams. Methods: Fourteen survey questions were developed by WGTG51 and released in November 2015. The questions collected information on reference dosimetry, beam quality specification, and ancillary calibration equipment. Results: Of the 190 submissions completed worldwide (U.S. 70%), 83% were AAPM members. Of the respondents, 33.5% implemented the TG-51 addendum, with the maximum calibration difference for any photon beam, with respect to the original TG-51 protocol, being <1% for 97.4% of responses. One major finding is that 81.8% of respondents used the same cylindrical ionization chamber for photon and electron dosimetry, implying that many clinics are foregoing the use of parallel-plate chambers. Other evidence suggests equivalent dosimetric results can be obtained with both cylindrical and parallel-plate chambers in electron beams. This, combined with users comfort with cylindrical chambers for electrons will likely impact recommendations put forward in an upcoming electron beam addendum to the TG-51 protocol. Data collected on ancillary equipment showed 58.2% (45.0%) of the thermometers (barometers) in use for beam calibration had NIST traceable calibration certificates, but 48.4% (42.7%) were never recalibrated. Conclusion: This survey provides a snapshot of TG-51 external beam reference dosimetry practice in radiotherapy centers. Findings demonstrate the rapid take-up of the TG-51 photon beam addendum and raise issues for the WGTG51 to focus on going forward, including guidelines on ancillary equipment and the choice of chamber for electron beam

  6. Comparison of Centers for Disease Control and Prevention and World Health Organization references/standards for height in contemporary Australian children: analyses of the Raine Study and Australian National Children's Nutrition and Physical Activity cohorts.

    Science.gov (United States)

    Hughes, Ian; Harris, Mark; Cotterill, Andrew; Garnett, Sarah; Bannink, Ellen; Pennell, Craig; Sly, Peter; Leong, Gary M; Cowell, Chris; Ambler, Geoff; Werther, George; Hofman, Paul; Cutfield, Wayne; Choong, Catherine S

    2014-11-01

    (i) To compare the Centers for Disease Control and Prevention (CDC) reference and World Health Organization (WHO) standard/reference for height, particularly with respect to short stature and eligibility for growth hormone (GH) treatment by applying them to contemporary Australian children; (ii) To examine the implications for identifying short stature and eligibility for GH treatment. Children from the longitudinal Raine Study were serially measured for height from 1991 to 2005 (2-15-year-old girls (660) and boys (702) from Western Australia). In the cross-sectional Australian National Children's Nutrition and Physical Activity survey (2-16-year-old boys (2415) and girls (2379) from all states), height was measured in 2007. Heights were converted to standard deviation scores (SDSs) based on CDC and WHO. Means and standard deviations of height-SDS varied between CDC and WHO definitions and with age and gender within each definition. However, both identified similar frequencies of short stature (standard/reference for height. © 2014 The Authors. Journal of Paediatrics and Child Health © 2014 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  7. Is PCR the Next Reference Standard for the Diagnosis of Schistosoma in Stool? A Comparison with Microscopy in Senegal and Kenya.

    NARCIS (Netherlands)

    Meurs, L.; Brienen, E.; Mbow, M.; Ochola, E.A,; Mboup, S.; Karanja, D.M.; Secor, W.E.; Polman, K.; Lieshout, L.

    2015-01-01

    Background The current reference test for the detection of S. mansoni in endemic areas is stool microscopy based on one or more Kato-Katz stool smears. However, stool microscopy has several shortcomings that greatly affect the efficacy of current schistosomiasis control programs. A highly specific

  8. Hg0 and HgCl2 Reference Gas Standards: NIST Traceability and Comparability (And EPA ALT Methods for Hg and HCl )

    Science.gov (United States)

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the tru...

  9. Development of Automated Procedures to Generate Reference Building Models for ASHRAE Standard 90.1 and India’s Building Energy Code and Implementation in OpenStudio

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Andrew [National Renewable Energy Lab. (NREL), Golden, CO (United States); Haves, Philip [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Jegi, Subhash [International Institute of Information Technology, Hyderabad (India); Garg, Vishal [International Institute of Information Technology, Hyderabad (India); Ravache, Baptiste [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-09-14

    This paper describes a software system for automatically generating a reference (baseline) building energy model from the proposed (as-designed) building energy model. This system is built using the OpenStudio Software Development Kit (SDK) and is designed to operate on building energy models in the OpenStudio file format.

  10. A reference tristimulus colorimeter

    Science.gov (United States)

    Eppeldauer, George P.

    2002-06-01

    A reference tristimulus colorimeter has been developed at NIST with a transmission-type silicon trap detector (1) and four temperature-controlled filter packages to realize the Commission Internationale de l'Eclairage (CIE) x(λ), y(λ) and z(λ) color matching functions (2). Instead of lamp standards, high accuracy detector standards are used for the colorimeter calibration. A detector-based calibration procedure is being suggested for tristimulus colorimeters wehre the absolute spectral responsivity of the tristimulus channels is determined. Then, color (spectral) correct and peak (amplitude) normalization are applied to minimize uncertainties caused by the imperfect realizations of the CIE functions. As a result of the corrections, the chromaticity coordinates of stable light sources with different spectral power distributions can be measured with uncertainties less than 0.0005 (k=1).

  11. Metabolic syndrome in children and adolescents from Mérida city, Venezuela: Comparison of results using local and international reference values (CREDEFAR study).

    Science.gov (United States)

    Villalobos Reyes, Marjorie; Mederico, Maracelly; Paoli de Valeri, Mariela; Briceño, Yajaira; Zerpa, Yajaira; Gómez-Pérez, Roald; Camacho, Nolis; Martínez, José Luis; Valeri, Lenín; Arata-Bellabarba, Gabriela

    2014-11-01

    To obtain local reference values for blood lipids and blood pressure (BP), and to determine the prevalence of metabolic syndrome (MS) in children and adolescents from Mérida, Venezuela, and to compare results using local and international cut-off values. The study enrolled 916 participants of both sexes aged 9-18 years of age from educational institutions. Demographic, anthropometric, and BP data were collected. Fasting blood glucose and lipid profile were measured. Percentile distribution of lipid and BP values was done by age group and sex. Prevalence of MS was estimated based on the NCEP-ATPIII classification (as modified by Cook et al.) and the classification of the International Diabetes Federation, using percentiles of Mérida and the USA as cut-off points. Agreement between both classifications was estimated using the kappa test (κ). Prevalence of MS was 2.2% by Cook-Merida percentiles, as compared to 1.8% by Cook-USA percentiles, a moderate agreement (κ=0.54). Agreement between Cook et al. and IDF using Merida percentiles was weak (κ=0.28). There was a higher frequency of abdominal obesity, hypertriglyceridemia and hypertension, and a lower frequency of low HDL-C using Mérida percentiles. The risk (odds ratio) of having MS is greater if abdominal obesity exists (OR: 98.63, CI: 22.45-433.35, p=0.0001). MS was significantly more common in obese subjects (18.3%, p=0.0001). Prevalence of MS in this sample of children and adolescents was 2.2%. Lipid and BP values were lower in Venezuelan as compared to US, European, and Asian children and adolescents, and similar to those in Latin-American references. Own reference values are required for accurate diagnosis of MS, as well as a worldwide consensus on its diagnostic criteria. Copyright © 2014 SEEN. Published by Elsevier Espana. All rights reserved.

  12. Performance evaluation of working standard NE2581 in comparison with reference standard NE2561 in the determination of absorbed dose to water using IAEA, HPA, NACP, AAPM, NCRP and ICRU protocols

    International Nuclear Information System (INIS)

    Dolah, M.T.; Supian Samat; Taiman Kadni

    2001-01-01

    The aim of this study was to evaluate the performance of NE 2581 in comparison with NE 2561 in the determination of the absorbed dose to water in a γ-ray beam using IAEA, HPA, NACP, AAPM, NCRP and ICRU protocols. 13 exposures of the γ-ray beams were used. This number of exposures yielded 26 chamber rate readings for NE 2581 (N=13) and for NE 2561 (N=13). From the 13 NE 2581 readings, 78 absorbed dose to water values were calculated for the IAEA (N=13), HPA (N=13), NACP (N=13), AAPM (N=13), NCRP (N=13) and ICRU (N=13) protocols. Similarly, from the 13 NE 2561 readings, 78 absorbed dose to water values were calculated for IAEA (N=13), HPA (N=13), NACP (N=13), AAPM (N=13), NCRP (N=13) and ICRU (N=13) protocols. From these 156 (=78 x 2) absorbed dose to water values, 78 percentage deviations between the NE 2581 and NE 2561 results were calculated for IAEA (N=13), HPA (N=13), NACP (N=13), AAPM (N=13), NCRP (N=13) and ICRU (N=13) protocols. For a single protocol, the mean μ and standard error σ+s+e of the percentage deviations (N=13) were calculated. results obtained in terms of [protocol, μ ± σ se ] were [IAEA,1.55 ± 0.12], [HPA, 0.98 ± 0.12], [NACP, 1.93 ± 0.12], [AAPM, -0.06 ± 0.12], [NCRP, 0.97 ± 0.12], [ICRU, 0.97 ± 0.12]. It can be seen that the range of percentage deviations is from -0.06 to 1.93. As the quoted IAEA acceptable limit of deviation is ± 3.0%, it was concluded that the working standard NE 2581 chamber has shown acceptable performance. In addition, the use of the AAPM protocol has enable NE 2581 to show a performance that is very similar like NE 2561. (Author)

  13. Standardization of the 24-hour diet recall calibration method used in the european prospective investigation into cancer and nutrition (EPIC): general concepts and preliminary results.

    Science.gov (United States)

    Slimani, N; Ferrari, P; Ocké, M; Welch, A; Boeing, H; Liere, M; Pala, V; Amiano, P; Lagiou, A; Mattisson, I; Stripp, C; Engeset, D; Charrondière, R; Buzzard, M; Staveren, W; Riboli, E

    2000-12-01

    Despite increasing interest in the concept of calibration in dietary surveys, there is still little experience in the use and standardization of a common reference dietary method, especially in international studies. In this paper, we present the general theoretical framework and the approaches developed to standardize the computer-assisted 24 h diet recall method (EPIC-SOFT) used to collect about 37 000 24-h dietary recall measurements (24-HDR) from the 10 countries participating in the European Prospective Investigation into Cancer and Nutrition (EPIC). In addition, an analysis of variance was performed to examine the level of standardization of EPIC-SOFT across the 90 interviewers involved in the study. The analysis of variance used a random effects model in which mean energy intake per interviewer was used as the dependent variable, while age, body mass index (BMI), energy requirement, week day, season, special diet, special day, physical activity and the EPIC-SOFT version were used as independent variables. The analysis was performed separately for men and women. The results show no statistical difference between interviewers in all countries for men and five out of eight countries for women, after adjustment for physical activity and the EPIC-SOFT program version used, and the exclusion of one interviewer in Germany (for men), and one in Denmark (for women). These results showed an interviewer effect in certain countries and a significant difference between gender, suggesting an underlying respondent's effect due to the higher under-reporting among women that was consistently observed in EPIC. However, the actual difference between interviewer and country mean energy intakes is about 10%. Furthermore, no statistical differences in mean energy intakes were observed across centres from the same country, except in Italy and Germany for men, and France and Spain for women, where the populations were recruited from areas scattered throughout the countries. Despite

  14. Cytomegalovirus sequence variability, amplicon length, and DNase-sensitive non-encapsidated genomes are obstacles to standardization and commutability of plasma viral load results.

    Science.gov (United States)

    Naegele, Klaudia; Lautenschlager, Irmeli; Gosert, Rainer; Loginov, Raisa; Bir, Katia; Helanterä, Ilkka; Schaub, Stefan; Khanna, Nina; Hirsch, Hans H

    2018-04-22

    Cytomegalovirus (CMV) management post-transplantation relies on quantification in blood, but inter-laboratory and inter-assay variability impairs commutability. An international multicenter study demonstrated that variability is mitigated by standardizing plasma volumes, automating DNA extraction and amplification, and calibration to the 1st-CMV-WHO-International-Standard as in the FDA-approved Roche-CAP/CTM-CMV. However, Roche-CAP/CTM-CMV showed under-quantification and false-negative results in a quality assurance program (UK-NEQAS-2014). To evaluate factors contributing to quantification variability of CMV viral load and to develop optimized CMV-UL54-QNAT. The UL54 target of the UK-NEQAS-2014 variant was sequenced and compared to 329 available CMV GenBank sequences. Four Basel-CMV-UL54-QNAT assays of 361 bp, 254 bp, 151 bp, and 95 bp amplicons were developed that only differed in reverse primer positions. The assays were validated using plasmid dilutions, UK-NEQAS-2014 sample, as well as 107 frozen and 69 prospectively collected plasma samples from transplant patients submitted for CMV QNAT, with and without DNase-digestion prior to nucleic acid extraction. Eight of 43 mutations were identified as relevant in the UK-NEQAS-2014 target. All Basel-CMV-UL54 QNATs quantified the UK-NEQAS-2014 but revealed 10-fold increasing CMV loads as amplicon size decreased. The inverse correlation of amplicon size and viral loads was confirmed using 1st-WHO-International-Standard and patient samples. DNase pre-treatment reduced plasma CMV loads by >90% indicating the presence of unprotected CMV genomic DNA. Sequence variability, amplicon length, and non-encapsidated genomes obstruct standardization and commutability of CMV loads needed to develop thresholds for clinical research and management. Besides regular sequence surveys, matrix and extraction standardization, we propose developing reference calibrators using 100 bp amplicons. Copyright © 2018 Elsevier B.V. All

  15. Standardized inspections of food premises during the 2004 Athens Olympic Games: descriptive analysis and risk factors for unsatisfactory results.

    Science.gov (United States)

    Hadjichristodoulou, Christos; Mouchtouri, Varvara; Varzakas, Theodoros; Arvanitoyannis, Ioannis; Kremastinou, Jenny

    2008-08-01

    Standardized inspections of food premises are part of environmental health systems implemented worldwide. The food safety strategy for the 2004 Olympic Games included standardized inspections to ensure uniformity and consistency of procedures and effective electronic management of data. Inspections were carried out by 196 inspectors in the five Olympic cities: Athens, Thessalonica, Volos, Iraklio, and Patra. From January 2003 to September 2004, a total of 1,249 food premises were inspected. An unsatisfactory inspection result (C grade) was received by 347 (27.8%) food premises, a relatively satisfactory result (B grade) was received by 332 (26.6%), and a satisfactory result (A grade) was received by 570 (45.6%). About 16% of inspected premises did not hold a valid permit. Unsatisfactory inspection results were more frequent for premises located in the two largest Greek cities in comparison with the other smaller cities (relative risk = 1.95, 95% confidence interval [CI] = 1.36 to 2.80). Based on logistic regression analysis, unsatisfactory inspection results were positively associated with food premises that were not located on a ground floor (odds ratio [OR] = 2.56, 95% CI = 1.39 to 4.73) and negatively associated with application of hazard analysis critical control point (HACCP) principles (OR = 0.27, 95% CI = 0.10 to 0.71). Food hygiene education through formal training programs should be encouraged to improve compliance of food premises. Food premises located on hotel floors and serving buffet meals are at higher risk for unsatisfactory conditions. Businesses that implemented a HACCP system within their operations to ensure food safety operated under more hygienic conditions. Future inspections by Public Health Authorities should involve elements of audit after the legislation for the application of HACCP principles.

  16. Using the Wisconsin-Ohio Reference Evaluation Program (WOREP) to Improve Training and Reference Services

    Science.gov (United States)

    Novotny, Eric; Rimland, Emily

    2007-01-01

    This article discusses a service quality study conducted in the Pennsylvania State University Libraries. The Wisconsin-Ohio Reference Evaluation Program survey was selected as a valid, standardized instrument. We present our results, highlighting the impact on reference training. A second survey a year later demonstrated that focusing on…

  17. Growth references

    NARCIS (Netherlands)

    Buuren, S. van

    2007-01-01

    A growth reference describes the variation of an anthropometric measurement within a group of individuals. A reference is a tool for grouping and analyzing data and provides a common basis for comparing populations.1 A well known type of reference is the age-conditional growth diagram. The

  18. Standardized programming to reduce the burden of inappropriate therapies in implantable cardioverter defibrillators - Single centre follow up results

    Directory of Open Access Journals (Sweden)

    U. Boles

    2018-03-01

    Full Text Available Background: Current algorithms and device morphology templates have been proposed in current Implantable Cardioverter-Defibrillators (ICDs to minimize inappropriate therapies (ITS, but this has not been completely successful. Aim: Assess the impact of a deliberate strategy of using an atrial lead implant with standardized parameters; based on all current ICD discriminators and technologies, on the burden of ITS. Method: A retrospective single-centre analysis of 250 patients with either dual chamber (DR ICDs or biventricular ICDs (CRTDs over a (41.9 ± 27.3 month period was performed. The incidence of ITS on all ICD and CRTD patients was chronicled after the implementation of standardized programming. Results: 39 events of anti-tachycardial pacing (ATP and/or shocks were identified in 20 patients (8% incidence rate among patients. The total number of individual therapies was 120, of which 34% were inappropriate ATP, and 36% were inappropriate shocks. 11 patients of the 250 patients received ITS (4.4%. Of the 20 patients, four had ICDs for primary prevention and 16 for a secondary prevention. All the episodes in the primary indication group were inappropriate, while seven patients (43% of the secondary indication group experienced inappropriate therapies. Conclusions: The burden of ITS in the population of patients receiving ICDs was 4.4% in the presence of atrial leads. The proposed rationalized programming criteria seems an effective strategy to minimize the burden of inappropriate therapies and will require further validation. Keywords: Implantable cardioverter-defibrillator (ICDs, Inappropriate therapies, Standardized programming

  19. Digital Dilemma: Intellectual Property [and] The ERCIM Technical Reference Digital Library [and] International Information Gateway Collaboration [and] The Standards Fora for Online Education.

    Science.gov (United States)

    Gladney, Henry M.; Andreoni, Antonella; Baldacci, Maria Bruna; Biagioni, Stefania; Carlesi, Carlo; Castelli, Donatella; Pagano, Pasquale; Peters, Carol; Pisani, Serena; Dempsey, Lorcan; Gardner, Tracy; Day, Michael; van der Werf, Titia; Bacsich, Paul; Heath, Andy; Lefrere, Paul; Miller, Paul; Riley, Kevin

    1999-01-01

    Includes four articles that discuss the impact of the emerging digital information infrastructure on intellectual property; the implementation of a digital library for a European consortium of national research institutions; an international information gateway collaboration; and developing standards for the description and sharing of educational…

  20. Standard-based comprehensive detection of adverse drug reaction signals from nursing statements and laboratory results in electronic health records.

    Science.gov (United States)

    Lee, Suehyun; Choi, Jiyeob; Kim, Hun-Sung; Kim, Grace Juyun; Lee, Kye Hwa; Park, Chan Hee; Han, Jongsoo; Yoon, Dukyong; Park, Man Young; Park, Rae Woong; Kang, Hye-Ryun; Kim, Ju Han

    2017-07-01

    We propose 2 Medical Dictionary for Regulatory Activities-enabled pharmacovigilance algorithms, MetaLAB and MetaNurse, powered by a per-year meta-analysis technique and improved subject sampling strategy. This study developed 2 novel algorithms, MetaLAB for laboratory abnormalities and MetaNurse for standard nursing statements, as significantly improved versions of our previous electronic health record (EHR)-based pharmacovigilance method, called CLEAR. Adverse drug reaction (ADR) signals from 117 laboratory abnormalities and 1357 standard nursing statements for all precautionary drugs ( n   = 101) were comprehensively detected and validated against SIDER (Side Effect Resource) by MetaLAB and MetaNurse against 11 817 and 76 457 drug-ADR pairs, respectively. We demonstrate that MetaLAB (area under the curve, AUC = 0.6