WorldWideScience

Sample records for reestablish baseline production

  1. Plant community, primary productivity, and environmental conditions following wetland re-establishment in the Sacramento-San Joaquin Delta, California

    Science.gov (United States)

    Miller, R.L.; Fujii, R.

    2010-01-01

    Wetland restoration can mitigate aerobic decomposition of subsided organic soils, as well as re-establish conditions favorable for carbon storage. Rates of carbon storage result from the balance of inputs and losses, both of which are affected by wetland hydrology. We followed the effect of water depth (25 and 55 cm) on the plant community, primary production, and changes in two re-established wetlands in the Sacramento San-Joaquin River Delta, California for 9 years after flooding to determine how relatively small differences in water depth affect carbon storage rates over time. To estimate annual carbon inputs, plant species cover, standing above- and below-ground plant biomass, and annual biomass turnover rates were measured, and allometric biomass models for Schoenoplectus (Scirpus) acutus and Typha spp., the emergent marsh dominants, were developed. As the wetlands developed, environmental factors, including water temperature, depth, and pH were measured. Emergent marsh vegetation colonized the shallow wetland more rapidly than the deeper wetland. This is important to potential carbon storage because emergent marsh vegetation is more productive, and less labile, than submerged and floating vegetation. Primary production of emergent marsh vegetation ranged from 1.3 to 3.2 kg of carbon per square meter annually; and, mid-season standing live biomass represented about half of the annual primary production. Changes in species composition occurred in both submerged and emergent plant communities as the wetlands matured. Water depth, temperature, and pH were lower in areas with emergent marsh vegetation compared to submerged vegetation, all of which, in turn, can affect carbon cycling and storage rates. ?? Springer Science+Business Media B.V. 2009.

  2. CryoSat SAR/SARin Level1b products: assessment of BaselineC and improvements towards BaselineD

    Science.gov (United States)

    Scagliola, Michele; Fornari, Marco; Bouffard, Jerome; Parrinello, Tommaso

    2017-04-01

    CryoSat was launched on the 8th April 2010 and is the first European ice mission dedicated to the monitoring of precise changes in the thickness of polar ice sheets and floating sea ice. Cryosat carries an innovative radar altimeter called the Synthetic Aperture Interferometric Altimeter (SIRAL), that transmits pulses at a high pulse repetition frequency thus making the received echoes phase coherent and suitable for azimuth processing. This allows to reach a significantly improved along track resolution with respect to traditional pulse-width limited altimeters. CryoSat is the first altimetry mission operating in SAR mode and continuous improvements in the Level1 Instrument Processing Facility (IPF1) are being identified, tested and validated in order to improve the quality of the Level1b products. The current IPF, Baseline C, was released in operation in April 2015 and the second CryoSat reprocessing campaign was jointly initiated, taking benefit of the upgrade implemented in the IPF1 processing chain but also of some specific configurations for the calibration corrections. In particular, the CryoSat Level1b BaselineC products generated in the framework of the second reprocessing campaign include refined information for what concerns the mispointing angles and the calibration corrections. This poster will thus detail thus the evolutions that are currently planned for the CryoSat BaselineD SAR/SARin Level1b products and the corresponding quality improvements that are expected.

  3. A case series of re-establishment of neuromuscular block with rocuronium after sugammadex reversal.

    Science.gov (United States)

    Iwasaki, Hajime; Sasakawa, Tomoki; Takahoko, Kenichi; Takagi, Shunichi; Nakatsuka, Hideki; Suzuki, Takahiro; Iwasaki, Hiroshi

    2016-06-01

    We report the use of rocuronium to re-establish neuromuscular block after reversal with sugammadex. The aim of this study was to investigate the relationship between the dose of rocuronium needed to re-establish neuromuscular block and the time interval between sugammadex administration and re-administration of rocuronium. Patients who required re-establishment of neuromuscular block within 12 h after the reversal of rocuronium-induced neuromuscular block with sugammadex were included. After inducing general anesthesia and placing the neuromuscular monitor, the protocol to re-establish neuromuscular block was as follows. An initial rocuronium dose of 0.6 mg/kg was followed by additional 0.3 mg/kg doses every 2 min until train-of-four responses were abolished. A total of 11 patients were enrolled in this study. Intervals between sugammadex and second rocuronium were 12-465 min. Total dose of rocuronium needed to re-establish neuromuscular block was 0.6-1.2 mg/kg. 0.6 mg/kg rocuronium re-established neuromuscular block in all patients who received initial sugammadex more than 3 h previously. However, when the interval between sugammadex and second rocuronium was less than 2 h, more than 0.6 mg/kg rocuronium was necessary to re-establish neuromuscular block.

  4. 75 FR 983 - Notice of Re-Establishment of the National Petroleum Council

    Science.gov (United States)

    2010-01-07

    ... DEPARTMENT OF ENERGY Notice of Re-Establishment of the National Petroleum Council AGENCY: Office of Fossil Energy, Department of Energy. ACTION: Notice of Re-Establishment of the National Petroleum... Secretariat, General Services Administration, notice is hereby given that the National Petroleum Council has...

  5. 78 FR 29382 - Notice of Charter Reestablishment

    Science.gov (United States)

    2013-05-20

    ... principles of the various criminal justice information systems managed by the FBI's CJIS Division. The APB... General, I have determined that the reestablishment of the Criminal Justice Information Services (CJIS... agencies participating in the CJIS Division Systems; and representatives of criminal justice professional...

  6. 76 FR 33785 - Notice of Charter Reestablishment

    Science.gov (United States)

    2011-06-09

    ... principles of the various criminal justice information systems managed by the FBI's CJIS Division. The APB... General, I have determined that the reestablishment of the Criminal Justice Information Services (CJIS... agencies participating in the CJIS Division Systems; and representatives of criminal justice professional...

  7. 49 CFR 24.304 - Reestablishment expenses-nonresidential moves.

    Science.gov (United States)

    2010-10-01

    ..., such as paint, paneling, or carpeting. (5) Advertisement of replacement location. (6) Estimated... or rental charges; (ii) Personal or real property taxes; (iii) Insurance premiums; and (iv) Utility charges, excluding impact fees. (7) Other items that the Agency considers essential to the reestablishment...

  8. 78 FR 30737 - Irish Potatoes Grown in Colorado; Reestablishment of Membership on the Colorado Potato...

    Science.gov (United States)

    2013-05-23

    ... FR] Irish Potatoes Grown in Colorado; Reestablishment of Membership on the Colorado Potato...: This final rule reestablishes the membership on the Colorado Potato Administrative Committee, Area No... Irish potatoes grown in Colorado. This action modifies the Committee membership structure by amending...

  9. 76 FR 7807 - National Wildlife Services Advisory Committee; Reestablishment

    Science.gov (United States)

    2011-02-11

    ... Inspection Service [Docket No. APHIS-2009-0057] National Wildlife Services Advisory Committee.... SUMMARY: We are giving notice that the Secretary of Agriculture will reestablish the National Wildlife.... SUPPLEMENTARY INFORMATION: The purpose of the National Wildlife Services Advisory Committee (the Committee) is...

  10. Estimation of the time since death--reconsidering the re-establishment of rigor mortis.

    Science.gov (United States)

    Anders, Sven; Kunz, Michaela; Gehl, Axel; Sehner, Susanne; Raupach, Tobias; Beck-Bornholdt, Hans-Peter

    2013-01-01

    In forensic medicine, there is an undefined data background for the phenomenon of re-establishment of rigor mortis after mechanical loosening, a method used in establishing time since death in forensic casework that is thought to occur up to 8 h post-mortem. Nevertheless, the method is widely described in textbooks on forensic medicine. We examined 314 joints (elbow and knee) of 79 deceased at defined time points up to 21 h post-mortem (hpm). Data were analysed using a random intercept model. Here, we show that re-establishment occurred in 38.5% of joints at 7.5 to 19 hpm. Therefore, the maximum time span for the re-establishment of rigor mortis appears to be 2.5-fold longer than thought so far. These findings have major impact on the estimation of time since death in forensic casework.

  11. Re-establishment of RTG unicouple production

    International Nuclear Information System (INIS)

    Braun, J.F.; Kuhl, K.D.

    1992-01-01

    The approach that was utilized to start u and requalify manufacture of the thermoelectric unicouple devices for the Cassini RTG (Radioisotope Thermoelectric Generator) program are described in this paper. Key elements involved in this effort were: engineering review of specifications; training of operators; manufacturing product verification runs; and management review of results. Appropriately, issues involved in activating a fabrication process that has been idle for nearly a decade, such as upgrading equipment, adhering to updated environmental, health, and safety requirements, or approving new vendors, are also addressed. The cumulative results of the startup activities have verified that a production line for this type of device can be reopened successfully

  12. 77 FR 52700 - Reestablishment of Department of Defense Federal Advisory Committees

    Science.gov (United States)

    2012-08-30

    ...), the Department of Defense gives notice that it is reestablishing the charter for the Board of Visitors... advice and recommendations on the overall management and governance of the National Defense University in...

  13. Loss and re-establishment of desiccation tolerance in the germinated seeds of Sesbania virgata (Cav. (Pers.

    Directory of Open Access Journals (Sweden)

    Tathiana Elisa Masetto

    2015-08-01

    Full Text Available This research aimed to investigate the cellular alterations during the loss and re-establishment of desiccation tolerance (DT in germinated Sesbania virgata seeds. The loss of DT was characterized in germinated seeds with increasing radicle lengths (1, 2, 3, 4 and 5 mm when subjected to dehydration in silica gel, followed by rehydration. To re-establish DT, the germinated seeds were incubated for 72h in polyethylene glycol (PEG, -2.04 MPa with or without ABA (100 μM before dehydration in silica gel. Cell viability was assessed by seedling survival, and DNA integrity was evaluated by gel electrophoresis. Seeds with 1 mm radicle length survived dehydration to the original moisture content (MC of the dry seed (approximately 10%. PEG treatment was able to re-establish DT, at least partially, with 2, 3 and 4 mm but not in 5 mm radicle lengths. Germinated seeds treated with PEG+ABA performed better than those treated only with PEG, and DT was re-established even in germinated seeds with a 5 mm radicle length. Among the PEG-treated germinated seeds dehydrated to 10% MC, DNA integrity was maintained only in those with a 1 mm radicle length.

  14. The re-establishment of hypersensitive cells in the crypts of irradiated mouse intestine

    International Nuclear Information System (INIS)

    Ijiri, K.; Potten, C.S.

    1984-01-01

    Two doses of γ-radiation separated by various time intervals have been used to investigate when after irradiation the cell population susceptible to acute cell death is re-established. Dead cells were scored 3 or 6 h after the second dose. Within 1-2 days of small doses (0.5 Gy) the sensitive cells, recognized histologically as apoptotic cells, are re-established at the base of the crypt (around cell position 6). After higher doses (9.0 Gy) they are not re-established until about the fourth day after irradiation. Even in the enlarged regenerating crypts the sensitive cells are found at the same position at the crypt base. It has been estimated that the crypt contains five or six cells that are susceptible to low doses (0.5 Gy) (hypersensitive cells) and up to a total of only seven or eight susceptible cells that can be induced by any dose to enter the sequence of changes implicit in apoptosis. Between 4 and 10 days after an intitial irradiation of 9.0 Gy the total number of susceptible cells increased from seven to eight to about 10 to 13 per crypt. (author)

  15. Re-establishment of rigor mortis: evidence for a considerably longer post-mortem time span.

    Science.gov (United States)

    Crostack, Chiara; Sehner, Susanne; Raupach, Tobias; Anders, Sven

    2017-07-01

    Re-establishment of rigor mortis following mechanical loosening is used as part of the complex method for the forensic estimation of the time since death in human bodies and has formerly been reported to occur up to 8-12 h post-mortem (hpm). We recently described our observation of the phenomenon in up to 19 hpm in cases with in-hospital death. Due to the case selection (preceding illness, immobilisation), transfer of these results to forensic cases might be limited. We therefore examined 67 out-of-hospital cases of sudden death with known time points of death. Re-establishment of rigor mortis was positive in 52.2% of cases and was observed up to 20 hpm. In contrast to the current doctrine that a recurrence of rigor mortis is always of a lesser degree than its first manifestation in a given patient, muscular rigidity at re-establishment equalled or even exceeded the degree observed before dissolving in 21 joints. Furthermore, this is the first study to describe that the phenomenon appears to be independent of body or ambient temperature.

  16. [Project summarize of "reestablishing disease prevention and control system of China"].

    Science.gov (United States)

    Hao, Mo; Yu, Jingjin; Yu, Mingzhu; Duan, Yong

    2005-01-01

    This paper introduced the project of "reestablishing the disease control and prevention system of China" in brief, including background, objectives, funding resources, researching objects and sampling methods. This project which funded by National Outstanding Younger Fund and the research fund of MOH aimed at nailing down the key problem existed in disease control and prevention system of China, demonstrating the reasons and mechanism of key problem, developing feasible policy idea and strategy. This paper also introduced some issues concerning the reestablishing of the disease control and prevention system of China: the definition of public function, the standard of human resource allocation and the standard of financing. The Centers for Disease Control and Prevention in 8 provinces, 80 cities and 80 counties have been sampled to provide information that project needed. In addition, this project also cited some data which come from the early study, in which 3 provinces, 12 counties, 49 towns, 179 villages and 9781 rural families have been sampled and investigated.

  17. How to re-establish Openness as default? Towards a global joint initiative

    NARCIS (Netherlands)

    Stracke, Christian M.

    2017-01-01

    Stracke, C. M. (2016, 14 April). How to re-establish Openness as default? Towards a global joint initiative. Results from the Action Lab at the Open Education Global Conference 2016, Krakow, Poland. More about the Action Lab:

  18. Establishment, maintenance, and re-establishment of the safe and efficient steady-following state

    International Nuclear Information System (INIS)

    Pan Deng; Zheng Ying-Ping

    2015-01-01

    We present an integrated mathematical model of vehicle-following control for the establishment, maintenance, and re-establishment of the previous or new safe and efficient steady-following state. The hyperbolic functions are introduced to establish the corresponding mathematical models, which can describe the behavioral adjustment of the following vehicle steered by a well-experienced driver under complex vehicle following situations. According to the proposed mathematical models, the control laws of the following vehicle adjusting its own behavior can be calculated for its moving in safety, efficiency, and smoothness (comfort). Simulation results show that the safe and efficient steady-following state can be well established, maintained, and re-established by its own smooth (comfortable) behavioral adjustment with the synchronous control of the following vehicle’s velocity, acceleration, and the actual following distance. (paper)

  19. Innovative water withdrawal system re-establishes fish migration runs

    International Nuclear Information System (INIS)

    Anon.

    2008-01-01

    This article described a unique water withdrawal and fish bypass structure that is under construction in Oregon to re-establish anadromous fish runs and to improve water quality downstream of the Round Butte dam. Portland General Electric and the Confederated Tribes of the Warm Springs Reservation, which co-own the dam, have committed to re-establish fish runs in response to concerns over the declining numbers of salmon and trout in the region. Water intakes are routinely added at hydroelectric facilities to protect native fish in compliance with the Federal Energy Regulatory Commission and the Clean Water Act. The Round Butte Hydroelectric project had a complex set of challenges whereby surface-current directions had to be changed to help migrating salmon swim easily into a fish handling area and create a fish collection system. CH2M HILL designed the system which consists of a large floating structure, an access bridge, a large vertical conduit and a base structure resting on the lake bed. Instead of using 2D CAD file methods, CH2M HILL decided to take advantage of 3D models to visualize the complex geometry of these structures. The 3D models were used to help designers and consultants understand the issues, resolve conflicts and design solutions. The objective is to have the system operating by the 2009 migrating season. 1 ref., 4 figs

  20. Baseline process description for simulating plutonium oxide production for precalc project

    Energy Technology Data Exchange (ETDEWEB)

    Pike, J. A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-10-26

    Savannah River National Laboratory (SRNL) started a multi-year project, the PreCalc Project, to develop a computational simulation of a plutonium oxide (PuO2) production facility with the objective to study the fundamental relationships between morphological and physicochemical properties. This report provides a detailed baseline process description to be used by SRNL personnel and collaborators to facilitate the initial design and construction of the simulation. The PreCalc Project team selected the HB-Line Plutonium Finishing Facility as the basis for a nominal baseline process since the facility is operational and significant model validation data can be obtained. The process boundary as well as process and facility design details necessary for multi-scale, multi-physics models are provided.

  1. The Baseline Positron Production and Capture Scheme for CLIC

    CERN Document Server

    Dadoun, Olivier; Lepercq, Pierre; Poirier, Freddy; Variola, Alessandro; Chehab, Robert; Rinolfi, Louis; Vivoli, Alessandro; Strakhovenko, Vladimir; Xu, Chengai

    2010-01-01

    The CLIC study considers the hybrid source using channeling as the baseline for unpolarised positron production. The hybrid source uses a few GeV electron beam impinging on a tungsten crystal target. With the crystal oriented on its axis it results an intense relatively low energy photon beam. The later is then impinging on an amorphous tungsten target producing positrons by e+e− pair creation. Downstream the amorphous target, a capture section based on an adiabatic matching device followed by a 2 GHz Pre- Injector Linac focuses and accelerates the positron beam up to around 200 MeV

  2. 75 FR 70712 - General Conference Committee of the National Poultry Improvement Plan; Reestablishment

    Science.gov (United States)

    2010-11-18

    ...] General Conference Committee of the National Poultry Improvement Plan; Reestablishment AGENCY: Animal and... Poultry Improvement Plan (Committee) for a 2-year period. The Secretary of Agriculture has determined that.... Rhorer, Senior Coordinator, National Poultry Improvement Plan, VS, APHIS, USDA, Suite 101, 1498 Klondike...

  3. CryoSat Level1b SAR/SARin BaselineC: Product Format and Algorithm Improvements

    Science.gov (United States)

    Scagliola, Michele; Fornari, Marco; Di Giacinto, Andrea; Bouffard, Jerome; Féménias, Pierre; Parrinello, Tommaso

    2015-04-01

    CryoSat was launched on the 8th April 2010 and is the first European ice mission dedicated to the monitoring of precise changes in the thickness of polar ice sheets and floating sea ice. Cryosat carries an innovative radar altimeter called the Synthetic Aperture Interferometric Altimeter (SIRAL), that transmits pulses at a high pulse repetition frequency thus making the received echoes phase coherent and suitable for azimuth processing. This allows to reach a significantly improved along track resolution with respect to traditional pulse-width limited altimeters. CryoSat is the first altimetry mission operating in SAR mode and continuous improvements in the Level1 Instrument Processing Facility (IPF1) are being identified, tested and validated in order to improve the quality of the Level1b products. The current IPF, Baseline B, was released in operation in February 2012. A reprocessing campaign followed, in order to reprocess the data since July 2010. After more than 2 years of development, the release in operations of Baseline C is expected in the first half of 2015. BaselineC Level1b products will be distributed in an updated format, including for example the attitude information (roll, pitch and yaw) and, for SAR/SARIN, the waveform length doubled with respect to Baseline B. Moreveor, various algorithm improvements have been identified: • a datation bias of about -0.5195 ms will be corrected (SAR/SARIn) • a range bias of about 0.6730 m will be corrected (SAR/SARIn) • a roll bias of 0.1062 deg and a pitch bias of 0.0520 deg • Surface sample stack weighting to filter out the single look echoes acquired at highest look angle, that results in a sharpening of the 20Hz waveforms With the operational release of BaselineC, the second CryoSat reprocessing campaign will be initiated, taking benefit of the upgrade implemented in the IPF1 processing chain but also at IPF2 level. The reprocessing campaign will cover the full Cryosat mission starting on 16th July 2010

  4. Cryosat Level1b SAR/Sarin: Improving the Quality of the Baseline C Products

    Science.gov (United States)

    Scagliola, M.; Fornari, M.; Tagliani, N.; Frommknecht, B.; Bouffard, J.; Parrinello, T.

    2014-12-01

    CryoSat was launched on the 8th April 2010 and it is the first European ice mission dedicated to monitoring precise changes in the thickness of polar ice sheets and floating sea ice over a 3-year period. Cryosat carries an innovative radar altimeter called the Synthetic Aperture Interferometric Altimeter (SIRAL), that transmits pulses at a high pulse repetition frequency thus making the received echoes phase coherent and suitable for azimuth processing. This allows to reach a significantly improved along track resolution with respect to traditional pulse-width limited altimeters. CryoSat is the first altimetry mission operating in SAR mode and continuous improvement in the Level1 Instrument Processing Facility (IPF1) are being identified, tested and validated in order to improve the quality of the Level1b products. Towards the release of the BaselineC of the CryoSat Level1b SAR/SARin products, that is expected at the end of 2014, several improvements have been identified: a datation bias of about -0.5195 ms will be corrected a range bias of about 0.6730 m will be corrected The range window size will be doubled with respect to BaselineB, so that the in Level1b products the waveforms will be doubled too Improved processing for 1Hz echoes to have sharper waveforms Surface sample stack weighting to filter out the single look echoes acquired at highest look angle, that results in a sharpening of the 20Hz waveforms Additional auxiliary information related to the mispointing angles of the instrument as well as to the stacks of single look echoes will be added This poster details the main quality improvements that are foreseen to be included in the CryoSat Level1b SAR/SARin products in BaselineC.

  5. Determination of priority areas for the re-establishment of forest cover, based on the use of geotechnologies

    Directory of Open Access Journals (Sweden)

    Nelson Wellausen Dias

    2012-12-01

    Full Text Available The determination of priority areas for the re-establishment of forest cover in watersheds is directly associated to the probability of effective success of restoration processes. However, considering the complexity of the analysis and the large amount of spatial data necessary to accomplish that purpose, state of the art technological tools capable of processing multi-criteria analysis to support decision making are necessary. Thus, the current work developed for an area of 476 km² corresponding to the Una river watershed in the municipal district of Taubaté, SP, used a multi-criteria analysis based on the continuous classification and on Analytical Hierarchy Process (AHP paired comparisons techniques, available in the complete GIS package named SPRING (Georeferenced Information Processing System for generating a map of priority areas for the re-establishment of forest cover in that watershed. Results revealed a large area (26.6% of the entire watershed falling in the “Extreme Priority” class for forest cover re-establishment, what indicates the urgent need of environmental recovery of this basin considering that it is used for Taubaté city water supply. Results from this research support the decision making for resource optimization applied to priority areas in an operational way.

  6. Baseline Glass Development for Combined Fission Products Waste Streams

    International Nuclear Information System (INIS)

    Crum, Jarrod V.; Billings, Amanda Y.; Lang, Jesse B.; Marra, James C.; Rodriguez, Carmen P.; Ryan, Joseph V.; Vienna, John D.

    2009-01-01

    Borosilicate glass was selected as the baseline technology for immobilization of the Cs/Sr/Ba/Rb (Cs), lanthanide (Ln) and transition metal fission product (TM) waste steams as part of a cost benefit analysis study.(1) Vitrification of the combined waste streams have several advantages, minimization of the number of waste forms, a proven technology, and similarity to waste forms currently accepted for repository disposal. A joint study was undertaken by Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) to develop acceptable glasses for the combined Cs + Ln + TM waste streams (Option 1) and Cs + Ln combined waste streams (Option 2) generated by the AFCI UREX+ set of processes. This study is aimed to develop baseline glasses for both combined waste stream options and identify key waste components and their impact on waste loading. The elemental compositions of the four-corners study were used along with the available separations data to determine the effect of burnup, decay, and separations variability on estimated waste stream compositions.(2-5) Two different components/scenarios were identified that could limit waste loading of the combined Cs + LN + TM waste streams, where as the combined Cs + LN waste stream has no single component that is perceived to limit waste loading. Combined Cs + LN waste stream in a glass waste form will most likely be limited by heat due to the high activity of Cs and Sr isotopes.

  7. 77 FR 38040 - Reestablishment of the Renewable Energy and Energy Efficiency Advisory Committee and Solicitation...

    Science.gov (United States)

    2012-06-26

    ... of Reestablishment of the Renewable Energy and Energy Efficiency Advisory Committee and Solicitation.... exports of renewable energy and energy efficiency goods and services, in accordance with applicable United... of U.S. citizens who will represent U.S. companies in the renewable energy and energy efficiency...

  8. 40 CFR 82.17 - Apportionment of baseline production allowances for class II controlled substances.

    Science.gov (United States)

    2010-07-01

    ... allowances for class II controlled substances. 82.17 Section 82.17 Protection of Environment ENVIRONMENTAL... Consumption Controls § 82.17 Apportionment of baseline production allowances for class II controlled... 1,759,681 MDA Manufacturing HCFC-22 2,383,835 Solvay Solexis HCFC-142b 6,541,764 [ 74 FR 66446, Dec...

  9. The Re-Establishment of Desiccation Tolerance in Germinated Arabidopsis thaliana Seeds and Its Associated Transcriptome

    NARCIS (Netherlands)

    Maia de Oliveira, J.; Dekkers, S.J.W.; Provart, N.J.; Ligterink, W.; Hilhorst, H.W.M.

    2011-01-01

    The combination of robust physiological models with “omics” studies holds promise for the discovery of genes and pathways linked to how organisms deal with drying. Here we used a transcriptomics approach in combination with an in vivo physiological model of re-establishment of desiccation tolerance

  10. Intra-urinoma Rendezvous Using a Transconduit Approach to Re-establish Ureteric Integrity

    International Nuclear Information System (INIS)

    Anderson, Hugh; Alyas, Faisal; Edwin, Patrick Joseph

    2005-01-01

    Ureteric discontinuity following injury has been traditionally treated surgically. With the advent of improved interventional instrumentation it is possible to stent these lesions percutaneously, retrogradely or failing that using a combined (rendezvous) technique. We describe an intra-urinoma rendezvous procedure combining a percutaneous antegrade-transconduit retrograde technique of stent insertion to successfully re-establish ureteric integrity that was used following the failure of a percutaneous retrograde approach. We illustrate its usefulness as an alternative to surgery

  11. 78 FR 9629 - Irish Potatoes Grown in Colorado; Reestablishment of Membership on the Colorado Potato...

    Science.gov (United States)

    2013-02-11

    ... Service 7 CFR Part 948 [Doc. No. AMS-FV-12-0044; FV12-948-2 PR] Irish Potatoes Grown in Colorado; Reestablishment of Membership on the Colorado Potato Administrative Committee, Area No. 2 AGENCY: Agricultural... membership on the Colorado Potato Administrative Committee, Area No. 2 (Committee). The Committee locally...

  12. Fight for your breeding right: hierarchy re-establishment predicts aggression in a social queue.

    Science.gov (United States)

    Wong, Marian; Balshine, Sigal

    2011-04-23

    Social aggression is one of the most conspicuous features of animal societies, yet little is known about the causes of individual variation in aggression within social hierarchies. Recent theory suggests that when individuals form queues for breeding, variation in social aggression by non-breeding group members is related to their probability of inheriting breeding status. However, levels of aggression could also vary as a temporary response to changes in the hierarchy, with individuals becoming more aggressive as they ascend in rank, in order to re-establish dominance relationships. Using the group-living fish, Neolamprologus pulcher, we show that subordinates became more aggressive after they ascended in rank. Female ascenders exhibited more rapid increases in aggression than males, and the increased aggression was primarily directed towards group members of adjacent rather than non-adjacent rank, suggesting that social aggression was related to conflict over rank. Elevated aggression by ascenders was not sustained over time, there was no relationship between rank and aggression in stable groups, and aggression given by ascenders was not sex-biased. Together, these results suggest that the need to re-establish dominance relationships following rank ascension is an important determinant of variation in aggression in animal societies.

  13. 76 FR 28209 - Notice of Intent To Reestablish the National Genetic Resources Advisory Council, and Request for...

    Science.gov (United States)

    2011-05-16

    ... appointed members will be from the general public including leaders in, fields of public policy, trade... DEPARTMENT OF AGRICULTURE Agricultural Research Service Notice of Intent To Reestablish the National Genetic Resources Advisory Council, and Request for Nominations AGENCY: Agricultural Research...

  14. KIGAM Seafloor Observation System (KISOS) for the baseline study in monitoring of gas hydrate test production in the Ulleung Basin, Korea

    Science.gov (United States)

    Lee, Sung-rock; Chun, Jong-hwa

    2013-04-01

    For the baseline study in the monitoring gas hydrate test production in the Ulleung Basin, Korea Institute of Geoscience and Mineral Resources (KIGAM) has developed the KIGAM Seafloor Observation System (KISOS) for seafloor exploration using unmanned remotely operated vehicle connected with a ship by a cable. The KISOS consists of a transponder of an acoustic positioning system (USBL), a bottom finding pinger, still camera, video camera, water sampler, and measuring devices (methane, oxygen, CTD, and turbidity sensors) mounted on the unmanned ROV, and a sediment collecting device collecting sediment on the seafloor. It is very important to monitoring the environmental risks (gas leakage and production water/drilling mud discharge) which may be occurred during the gas hydrate test production drilling. The KISOS will be applied to solely conduct baseline study with the KIGAM seafloor monitoring system (KIMOS) of the Korean gas hydrate program in the future. The large scale of environmental monitoring program includes the environmental impact assessment such as seafloor disturbance and subsidence, detection of methane gas leakage around well and cold seep, methane bubbles and dissolved methane, change of marine environments, chemical factor variation of water column and seabed, diffusion of drilling mud and production water, and biological factors of biodiversity and marine habitats before and after drilling test well and nearby areas. The design of the baseline survey will be determined based on the result of SIMAP simulation in 2013. The baseline survey will be performed to provide the gas leakage and production water/drilling mud discharge before and after gas hydrate test production. The field data of the baseline study will be evaluated by the simulation and verification of SIMAP simulator in 2014. In the presentation, the authors would like introduce the configuration of KISOS and applicability to the seafloor observation for the gas hydrate test production in

  15. 76 FR 22924 - Re-Establishment of the National Space-Based Positioning, Navigation, and Timing (PNT) Advisory...

    Science.gov (United States)

    2011-04-25

    ... Government is necessary and in the public interest. Accordingly, NASA is re-establishing the National Space... advice on U.S. space-based PNT policy, planning, program management, and funding profiles in relation to... Advisory Board will function solely as an advisory body and will comply fully with the provisions of the...

  16. A new technology aimed at re-establishing a global sulphur supply/demand balance

    International Nuclear Information System (INIS)

    Slavens, A.F.; Jorgensen, C.; Ogg, D.

    2009-01-01

    The world's sulphur supply is mainly determined by involuntary production of elemental sulphur during the processing of oil and gas. As a result, sulphur supply is decoupled from demand, resulting in an imbalance between the two. For almost two decades, sulphur supply has exceeded demand, which has raised significant concerns for oil and gas producers such as where to store all of the excess sulphur, and how to transport a low-value commodity to market in an economically attractive fashion. Black and Veatch is involved in the development of a new technology called sulphur to energy process (STEP TM ) which has the potential to assist in balancing global sulphur supply and demand, as well as affording other benefits such as low-emission energy production. This paper presented the potential merits of the STEP as a means to reestablish a global sulphur supply/demand balance for the world trading market. It explored the other potential benefits that may result from the use of this new technology and compared STEP to other technologies and operating schemes that regulate sulphur supply. It was concluded that STEP has the potential to allow the processor to produce elemental sulphur when demand is high, or to provide safe and ecological disposal when demand is low, with the added benefits of energy recovery from the sulphur combustion process, and sour gas reservoir sweetening over time as sulphur dioxide reacts with hydrogen sulphide present in the reservoir. 13 refs., 3 tabs., 22 figs

  17. Vitamin D production after UVB exposure depends on baseline vitamin D and total cholesterol but not on skin pigmentation.

    Science.gov (United States)

    Bogh, Morten K B; Schmedes, Anne V; Philipsen, Peter A; Thieden, Elisabeth; Wulf, Hans C

    2010-02-01

    UVB radiation increases serum vitamin D level expressed as 25-hydroxyvitamin-D(3) (25(OH)D), but the influence of skin pigmentation, baseline 25(OH)D level, and total cholesterol has not been well characterized. To determine the importance of skin pigmentation, baseline 25(OH)D level, and total cholesterol on 25(OH)D production after UVB exposure, 182 persons were screened for 25(OH)D level. A total of 50 participants with a wide range in baseline 25(OH)D levels were selected to define the importance of baseline 25(OH)D level. Of these, 28 non-sun worshippers with limited past sun exposure were used to investigate the influence of skin pigmentation and baseline total cholesterol. The participants had 24% of their skin exposed to UVB (3 standard erythema doses) four times every second or third day. Skin pigmentation and 25(OH)D levels were measured before and after the irradiations. Total cholesterol was measured at baseline. The increase in 25(OH)D level after UVB exposure was negatively correlated with baseline 25(OH)D level (Ppigmentation. In addition, we paired a dark-skinned group with a fair-skinned group according to baseline 25(OH)D levels and found no differences in 25(OH)D increase after identical UVB exposure.

  18. Vitamin D production after UVB exposure depends on baseline vitamin D and total cholesterol but not on skin pigmentation

    DEFF Research Database (Denmark)

    Bogh, Morten K B; Schmedes, Anne; Philipsen, Peter A

    2010-01-01

    UVB radiation increases serum vitamin D level expressed as 25-hydroxyvitamin-D(3) (25(OH)D), but the influence of skin pigmentation, baseline 25(OH)D level, and total cholesterol has not been well characterized. To determine the importance of skin pigmentation, baseline 25(OH)D level, and total...... cholesterol on 25(OH)D production after UVB exposure, 182 persons were screened for 25(OH)D level. A total of 50 participants with a wide range in baseline 25(OH)D levels were selected to define the importance of baseline 25(OH)D level. Of these, 28 non-sun worshippers with limited past sun exposure were used...... to investigate the influence of skin pigmentation and baseline total cholesterol. The participants had 24% of their skin exposed to UVB (3 standard erythema doses) four times every second or third day. Skin pigmentation and 25(OH)D levels were measured before and after the irradiations. Total cholesterol...

  19. Rapid orthodontic extrusion using an interocclusal appliance for the reestablishment of biologic width: a case report.

    Science.gov (United States)

    Kim, Sung Hyun; Tramontina, Vinicius Augusto; Papalexiou, Vula; Luczyszyn, Sônia Mara; Grassi, Maria Bibiana; de Fatima Scarpim, Maria; Tanaka, Orlando Motohiro

    2011-03-01

    A multidisciplinary treatment of a case of subgingival fracture in a maxillary anterior tooth is presented. This case report describes a simple method involving an interocclusal appliance and an elastic band for rapid orthodontic extrusion to reestablish biologic width. In addition, a simple technique for surgical recontouring following the coronal displacement of the gingival margin prior to restoration of fractured tooth is explained.

  20. Large-baseline InSAR for precise topographic mapping: a framework for TanDEM-X large-baseline data

    Directory of Open Access Journals (Sweden)

    M. Pinheiro

    2017-09-01

    Full Text Available The global Digital Elevation Model (DEM resulting from the TanDEM-X mission provides information about the world topography with outstanding precision. In fact, performance analysis carried out with the already available data have shown that the global product is well within the requirements of 10 m absolute vertical accuracy and 2 m relative vertical accuracy for flat to moderate terrain. The mission's science phase took place from October 2014 to December 2015. During this phase, bistatic acquisitions with across-track separation between the two satellites up to 3.6 km at the equator were commanded. Since the relative vertical accuracy of InSAR derived elevation models is, in principle, inversely proportional to the system baseline, the TanDEM-X science phase opened the doors for the generation of elevation models with improved quality with respect to the standard product. However, the interferometric processing of the large-baseline data is troublesome due to the increased volume decorrelation and very high frequency of the phase variations. Hence, in order to fully profit from the increased baseline, sophisticated algorithms for the interferometric processing, and, in particular, for the phase unwrapping have to be considered. This paper proposes a novel dual-baseline region-growing framework for the phase unwrapping of the large-baseline interferograms. Results from two experiments with data from the TanDEM-X science phase are discussed, corroborating the expected increased level of detail of the large-baseline DEMs.

  1. Research on the re-establishment of the classification criteria of strategic items

    Energy Technology Data Exchange (ETDEWEB)

    Han, Seong Mi; Yang, Seunghyo; Shin, Dong Hoon [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)

    2014-05-15

    According to these export control laws and regulations, the exporters have to apply the review for classification and export licensing to their own government. In this process, a technical review institute such as Korea Institute of Nuclear Nonproliferation and Control (institute under the NSSC) are referring to Minister's Regulation for the Export and Import of Strategic Goods. In this regulation, there are many criteria to classify the strategic items to be exported. But there are some problems in these criteria. At Typical problem is that classification criteria of Trigger List Items generally is very qualitative and very obscure in contrast with Dual Use Items. So, in most cases, this characteristics of classification criteria of trigger list items have caused much trouble for stakeholders such as government and nuclear related companies. So, there were needs that the classification criteria had to be more correct, obvious and objective. To solve these problems, the past classification cases for technology were re-analyzed and the general criteria were deducted in this study. Previously mentioned, the classification process and criteria were very qualitative and very obscure for the Trigger List Items. So, the re-establishment of the classification criteria was done to solve these problems in this study. Each extracted results were shown in Tables I and II. This re-established criteria are expected to contribute to quantification, disambiguation and objectification of the classification review process. As the future works, we will establish the probability or numerical factor for the extracted criteria through statistical surveys, to make better use of these criteria. And we will push ahead with the NSSC approval to use as the classification guidelines of the trigger list items in review processes.

  2. Will cross-ownership reestablish market power in the Nordic power market?

    International Nuclear Information System (INIS)

    Amundsen, Eirik S.; Bergman, Lars

    2000-01-01

    The integration of the power markets in Norway and Sweden in 1996 significantly constrained the major power companies' ability to exercise market power within their national borders. In recent years, however, mergers and reciprocal acquisition of shares have reduced the number of independent players on the Norwegian-Swedish power market. The aim of this paper is to explore to what extent increasing cross-ownership among major power companies in Norway and Sweden might re-establish the market power that was lost when the two national power markets were integrated. The analysis is based on a numerical model, assuming Cournot quantity setting behaviour, of the Norwegian-Swedish power market. The simulation results suggest that partial ownership relations between major generators and other power-producing firms tend to increase horizontal market power and thus the market price of electricity. (author)

  3. Re-establishment of the air kerma and ambient dose equivalent standards for the BIPM protection-level 60Co beam

    International Nuclear Information System (INIS)

    Kessler, C.; Roger, P.

    2005-07-01

    The air kerma and ambient dose equivalent standards for the protection-level 60 Co beam have been re-established following the repositioning of the irradiator and modifications to the beam. Details concerning the standards and the new uncertainty budgets are described in this report with their implications for dosimetry comparisons and calibrations. (authors)

  4. Orthodontic extrusion of subgingivally fractured tooth using a removable appliance: an alternative treatment to reestablish biological width.

    Science.gov (United States)

    Verma, Kanika Gupta; Juneja, Suruchi; Kumar, Sandeep; Goyal, Tanya

    2014-01-01

    Restoration of a traumatically injured tooth presents a clinical challenge for a predictable aesthetic outcome. This case report describes a multidisciplinary approach of a subgingivally fractured permanent maxillary central incisor. A removable orthodontic appliance was used for orthodontic extrusion of root, and surgical gingival recontouring was done with electrocautery to reestablish the biological width. Form and function were restored establishing biological width and esthetics was repaired with porcelain fused to metal crown.

  5. A study of man made radioactivity baseline in dietary materials

    International Nuclear Information System (INIS)

    de la Paz, L.; Estacio, J.; Palattao, M.V.; Anden, A.

    1986-01-01

    This paper describes the radioactivity baseline from literature data coming from various countries where data are available. 1979-1985 were chosen as the baseline years for the following: milk (fresh and powdered), meat and meat products, cereals, fruits, coffee and tea, fish and vegetables. Pre- and post-Chernobyl baseline data are given. (ELC). 21 figs; 17 refs

  6. Facial skin care products and cosmetics.

    Science.gov (United States)

    Draelos, Zoe Diana

    2014-01-01

    Facial skin care products and cosmetics can both aid or incite facial dermatoses. Properly selected skin care can create an environment for barrier repair aiding in the re-establishment of a healing biofilm and diminution of facial redness; however, skin care products that aggressively remove intercellular lipids or cause irritation must be eliminated before the red face will resolve. Cosmetics are an additive variable either aiding or challenging facial skin health. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Effectiveness of prescribed fire to re-establish sagebrush vegetation and ecohydrologic function on woodland-encroached sagebrush steppe, Great Basin, USA

    Science.gov (United States)

    Williams, C. J.; Pierson, F. B.; Kormos, P.; Al-Hamdan, O. Z.; Nouwakpo, S.; Weltz, M.; Vega, S.; Lindsay, K.

    2017-12-01

    Range expansion of pinyon (Pinus spp.) and juniper (Juniperus spp.) conifers into sagebrush steppe (Artemisia spp.) communities has imperiled a vast domain in the western US. Encroachment of sagebrush ecosystems by pinyon and juniper conifers has negative ramifications to ecosystem structure and function and delivery of goods and services. Scientists, land management agencies, and private land owners throughout the western US are challenged with selecting from a suite of options to reduce pinyon and juniper woody fuels and re-establish sagebrush steppe structure and function. This study evaluated the effectiveness of prescribed fire to re-establish sagebrush vegetation and ecohydrologic function over a 9 yr period. Nine years post-fire hydrologic and erosion responses reflect the combination of pre-fire site conditions, perennial grass recruitment, delayed litter cover, and inherent site characteristics. Burning initially increased bare ground, runoff, and erosion for well-vegetated areas underneath tree and shrub canopies, but had minimal impact on hydrology and erosion for degraded interspaces between plants. The degraded interspaces were primarily bare ground and exhibited high runoff and erosion rates prior to burning. Initial fire effects persisted for two years, but increased productivity of grasses improved hydrologic function of interspaces over the full 9 yr period. At the hillslope scale, grass recruitment in the intercanopy between trees reduced runoff from rainsplash, sheetflow, and concentrated overland flow at one site, but did not reduce the high levels of runoff and erosion from a more degraded site. In areas formerly occupied by trees (tree zones), burning increased invasive annual grass cover due to fire removal of limited native perennial plants and competition for resources. The invasive annual grass cover had no net effect on runoff and erosion from tree zones however. Runoff and erosion increased in tree zones at the more degraded site due to

  8. Active ex situ protection and reestablishment of Dianthus gratianopolitanus Vill. in the “Goździk siny w Grzybnie” reserve (Wielkopolska Province

    Directory of Open Access Journals (Sweden)

    Jańczyk-Węglarska Jolanta

    2013-12-01

    Full Text Available The following paper presents the results of observations of the size and condition of cheddar pink (Dianthus gratianopolitanus Vill. population in the “Goździk siny w Grzybnie” reserve (Wielkopolska Province, as well as active cultivation of the species in ex situ controlled conditions and its reestablishment supporting the natural, endangered population in the reserve

  9. 40 CFR 74.20 - Data for baseline and alternative baseline.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Data for baseline and alternative baseline. 74.20 Section 74.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... baseline and alternative baseline. (a) Acceptable data. (1) The designated representative of a combustion...

  10. CryoSat Ice Processor: High-Level Overview of Baseline-C Data and Quality-Control

    Science.gov (United States)

    Mannan, R.; Webb, E.; Hall, A.; Bouffard, J.; Femenias, P.; Parrinello, T.; Bouffard, J.; Brockley, D.; Baker, S.; Scagliola, M.; Urien, S.

    2016-08-01

    Since April 2015, the CryoSat ice products have been generated with the new Baseline-C Instrument Processing Facilities (IPFs). This represents a major upgrade to the CryoSat ice IPFs and is the baseline for the second CryoSat Reprocessing Campaign. Baseline- C introduces major evolutions with respect to Baseline- B, most notably the release of freeboard data within the L2 SAR products, following optimisation of the SAR retracker. Additional L2 improvements include a new Arctic Mean Sea Surface (MSS) in SAR; a new tuneable land ice retracker in LRM; and a new Digital Elevation Model (DEM) in SARIn. At L1B new attitude fields have been introduced and existing datation and range biases reduced. This paper provides a high level overview of the changes and evolutions implemented at Baseline-C in order to improve CryoSat L1B and L2 data characteristics and exploitation over polar regions. An overview of the main Quality Control (QC) activities performed on operational Baseline-C products is also presented.

  11. A long baseline global stereo matching based upon short baseline estimation

    Science.gov (United States)

    Li, Jing; Zhao, Hong; Li, Zigang; Gu, Feifei; Zhao, Zixin; Ma, Yueyang; Fang, Meiqi

    2018-05-01

    In global stereo vision, balancing the matching efficiency and computing accuracy seems to be impossible because they contradict each other. In the case of a long baseline, this contradiction becomes more prominent. In order to solve this difficult problem, this paper proposes a novel idea to improve both the efficiency and accuracy in global stereo matching for a long baseline. In this way, the reference images located between the long baseline image pairs are firstly chosen to form the new image pairs with short baselines. The relationship between the disparities of pixels in the image pairs with different baselines is revealed by considering the quantized error so that the disparity search range under the long baseline can be reduced by guidance of the short baseline to gain matching efficiency. Then, the novel idea is integrated into the graph cuts (GCs) to form a multi-step GC algorithm based on the short baseline estimation, by which the disparity map under the long baseline can be calculated iteratively on the basis of the previous matching. Furthermore, the image information from the pixels that are non-occluded under the short baseline but are occluded for the long baseline can be employed to improve the matching accuracy. Although the time complexity of the proposed method depends on the locations of the chosen reference images, it is usually much lower for a long baseline stereo matching than when using the traditional GC algorithm. Finally, the validity of the proposed method is examined by experiments based on benchmark datasets. The results show that the proposed method is superior to the traditional GC method in terms of efficiency and accuracy, and thus it is suitable for long baseline stereo matching.

  12. Campus Improvement Committee Working to Increase Morale, Productivity | Poster

    Science.gov (United States)

    The Campus Improvement Committee (CIC) has recently been re-established, with Mike Addington, manager, Operations and Maintenance, as chair. Addington is excited to be involved in a committee that’s so near and dear to his heart, and he’s a big believer in the value of increasing morale and productivity through an appealing and pleasant work environment.

  13. Baseline scenarios of global environmental change

    International Nuclear Information System (INIS)

    Alcamo, J.; Kreileman, G.J.J.; Bollen, J.C.; Born, G.J. van den; Krol, M.S.; Toet, A.M.C.; Vries, H.J.M. de; Gerlagh, R.

    1996-01-01

    This paper presents three baseline scenarios of no policy action computed by the IMAGE2 model. These scenarios cover a wide range of coupled global change indicators, including: energy demand and consumption; food demand, consumption, and production; changes in land cover including changes in extent of agricultural land and forest; emissions of greenhouse gases and ozone precursors; and climate change and its impacts on sea level rise, crop productivity and natural vegetation. Scenario information is available for the entire world with regional and grid scale detail, and covers from 1970 to 2100. (author)

  14. An Energy Efficiency Evaluation Method Based on Energy Baseline for Chemical Industry

    OpenAIRE

    Yao, Dong-mei; Zhang, Xin; Wang, Ke-feng; Zou, Tao; Wang, Dong; Qian, Xin-hua

    2016-01-01

    According to the requirements and structure of ISO 50001 energy management system, this study proposes an energy efficiency evaluation method based on energy baseline for chemical industry. Using this method, the energy plan implementation effect in the processes of chemical production can be evaluated quantitatively, and evidences for system fault diagnosis can be provided. This method establishes the energy baseline models which can meet the demand of the different kinds of production proce...

  15. An Energy Efficiency Evaluation Method Based on Energy Baseline for Chemical Industry

    Directory of Open Access Journals (Sweden)

    Dong-mei Yao

    2016-01-01

    Full Text Available According to the requirements and structure of ISO 50001 energy management system, this study proposes an energy efficiency evaluation method based on energy baseline for chemical industry. Using this method, the energy plan implementation effect in the processes of chemical production can be evaluated quantitatively, and evidences for system fault diagnosis can be provided. This method establishes the energy baseline models which can meet the demand of the different kinds of production processes and gives the general solving method of each kind of model according to the production data. Then the energy plan implementation effect can be evaluated and also whether the system is running normally can be determined through the baseline model. Finally, this method is used on cracked gas compressor unit of ethylene plant in some petrochemical enterprise; it can be proven that this method is correct and practical.

  16. 7 CFR 930.21 - Reestablishment.

    Science.gov (United States)

    2010-01-01

    ... production within the districts and the production area; (e) Changes in the proportion and role of growers... Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... relative importance of producing areas; (b) Relative production; (c) The geographic locations of producing...

  17. NA61/SHINE Data For Long Baseline Neutrino Experiments

    CERN Document Server

    Hälser, Alexis

    2015-01-01

    Accelerator based long baseline neutrino experiments require precise neutrino fl ux predictions to reach their physics goals. These experiments are commonly based on a set of two detectors. At the near detector, cross section measurements are performed and the neutrino fl ux can be observed before oscillation, while at the far detector the signal for neutrino oscillations is studied. An accurate knowledge on hadron production is mandatory in order to predict the neutrino fluxes. The NA61/SHINE facility at the CERN SPS has proven its ability to deliver high quality measurements of hadron production for the long baseline neutrino experiments. In this paper, the latest results from N A61 /SHINE for the neutrino physics programme are reviewed and future plans are presented.

  18. Reestablishment of radiographic kidney size in Miniature Schnauzer dogs.

    Science.gov (United States)

    Sohn, Jungmin; Yun, Sookyung; Lee, Jeosoon; Chang, Dongwoo; Choi, Mincheol; Yoon, Junghee

    2017-01-10

    Kidney size may be altered in renal diseases, and the detection of kidney size alteration has diagnostic and prognostic values. We hypothesized that radiographic kidney size, the kidney length to the second lumbar vertebra (L2) length ratio, in normal Miniature Schnauzer dogs may be overestimated due to their shorter vertebral length. This study was conducted to evaluate radiographic and ultrasonographic kidney size and L2 length in clinically normal Miniature Schnauzers and other dog breeds to evaluate the effect of vertebral length on radiographic kidney size and to reestablish radiographic kidney size in normal Miniature Schnauzers. Abdominal radiographs and ultrasonograms from 49 Miniature Schnauzers and 54 other breeds without clinical evidence of renal disease and lumbar vertebral abnormality were retrospectively evaluated. Radiographic kidney size, in the Miniature Schnauzer (3.31 ± 0.26) was significantly larger than that in other breeds (2.94 ± 0.27). Relative L2 length, the L2 length to width ratio, in the Miniature Schnauzer (1.11 ± 0.06) was significantly shorter than that in other breeds (1.21 ± 0.09). However, ultrasonographic kidney sizes, kidney length to aorta diameter ratios, were within or very close to normal range both in the Miniature Schnauzer (6.75 ± 0.67) and other breeds (7.16 ± 1.01). Thus, Miniature Schnauzer dogs have breed-specific short vertebrae and consequently a larger radiographic kidney size, which was greater than standard reference in normal adult dogs. Care should be taken when evaluating radiographic kidney size in Miniature Schnauzers to prevent falsely diagnosed renomegaly.

  19. Developing RESRAD-BASELINE for environmental baseline risk assessment

    International Nuclear Information System (INIS)

    Cheng, Jing-Jy.

    1995-01-01

    RESRAD-BASELINE is a computer code developed at Argonne developed at Argonne National Laboratory for the US Department of Energy (DOE) to perform both radiological and chemical risk assessments. The code implements the baseline risk assessment guidance of the US Environmental Protection Agency (EPA 1989). The computer code calculates (1) radiation doses and cancer risks from exposure to radioactive materials, and (2) hazard indexes and cancer risks from exposure to noncarcinogenic and carcinogenic chemicals, respectively. The user can enter measured or predicted environmental media concentrations from the graphic interface and can simulate different exposure scenarios by selecting the appropriate pathways and modifying the exposure parameters. The database used by PESRAD-BASELINE includes dose conversion factors and slope factors for radionuclides and toxicity information and properties for chemicals. The user can modify the database for use in the calculation. Sensitivity analysis can be performed while running the computer code to examine the influence of the input parameters. Use of RESRAD-BASELINE for risk analysis is easy, fast, and cost-saving. Furthermore, it ensures in consistency in methodology for both radiological and chemical risk analyses

  20. Erasure and reestablishment of random allelic expression imbalance after epigenetic reprogramming.

    Science.gov (United States)

    Jeffries, Aaron Richard; Uwanogho, Dafe Aghogho; Cocks, Graham; Perfect, Leo William; Dempster, Emma; Mill, Jonathan; Price, Jack

    2016-10-01

    Clonal level random allelic expression imbalance and random monoallelic expression provides cellular heterogeneity within tissues by modulating allelic dosage. Although such expression patterns have been observed in multiple cell types, little is known about when in development these stochastic allelic choices are made. We examine allelic expression patterns in human neural progenitor cells before and after epigenetic reprogramming to induced pluripotency, observing that loci previously characterized by random allelic expression imbalance (0.63% of expressed genes) are generally reset to a biallelic state in induced pluripotent stem cells (iPSCs). We subsequently neuralized the iPSCs and profiled isolated clonal neural stem cells, observing that significant random allelic expression imbalance is reestablished at 0.65% of expressed genes, including novel loci not found to show allelic expression imbalance in the original parental neural progenitor cells. Allelic expression imbalance was associated with altered DNA methylation across promoter regulatory regions, with clones characterized by skewed allelic expression being hypermethylated compared to their biallelic sister clones. Our results suggest that random allelic expression imbalance is established during lineage commitment and is associated with increased DNA methylation at the gene promoter. © 2016 Jeffries et al.; Published by Cold Spring Harbor Laboratory Press for the RNA Society.

  1. Re-establishing marshes can return carbon sink functions to a current carbon source in the Sacramento-San Joaquin Delta of California, USA

    Science.gov (United States)

    Miller, Robin L.; Fujii, Roger; Schmidt, Paul E.

    2011-01-01

    The Sacramento-San Joaquin Delta in California was an historic, vast inland freshwater wetland, where organic soils almost 20 meters deep formed over the last several millennia as the land surface elevation of marshes kept pace with sea level rise. A system of levees and pumps were installed in the late 1800s and early 1900s to drain the land for agricultural use. Since then, land surface has subsided more than 7 meters below sea level in some areas as organic soils have been lost to aerobic decomposition. As land surface elevations decrease, costs for levee maintenance and repair increase, as do the risks of flooding. Wetland restoration can be a way to mitigate subsidence by re-creating the environment in which the organic soils developed. A preliminary study of the effect of hydrologic regime on carbon cycling conducted on Twitchell Island during the mid-1990s showed that continuous, shallow flooding allowing for the growth of emergent marsh vegetation re-created a wetland environment where carbon preservation occurred. Under these conditions annual plant biomass carbon inputs were high, and microbial decomposition was reduced. Based on this preliminary study, the U.S. Geological Survey re-established permanently flooded wetlands in fall 1997, with shallow water depths of 25 and 55 centimeters, to investigate the potential to reverse subsidence of delta islands by preserving and accumulating organic substrates over time. Ten years after flooding, elevation gains from organic matter accumulation in areas of emergent marsh vegetation ranged from almost 30 to 60 centimeters, with average annual carbon storage rates approximating 1 kg/m2, while areas without emergent vegetation cover showed no significant change in elevation. Differences in accretion rates within areas of emergent marsh vegetation appeared to result from temporal and spatial variability in hydrologic factors and decomposition rates in the wetlands rather than variability in primary production

  2. Spent nuclear fuel technical baseline description, Fiscal Year 1996: Volume II, supporting data

    International Nuclear Information System (INIS)

    Womack, J.C.

    1995-11-01

    The Technical Baseline Description documents the Project-Level functions and requirements, along with associated enabling assumptions, issues, trade studies, interfaces, and products. It is a snapshot in time of the baseline at the beginning of September 1995. It supports the individual subprojects in the development of lower-tier functions, requirements, and specifications in FY 1996. It also supports the need for Hanford site planning to be based on an integrated Hanford site systems engineering technical baseline; and is traceable to that baseline. This document replaces and supercedes WHC-SD-SNF-SD-003

  3. LANDFIRE Remap: A New National Baseline Product Suite

    Science.gov (United States)

    Dockter, D.; Peterson, B.; Picotte, J. J.; Long, J.; Tolk, B.; Callahan, K.; Davidson, A.; Earnhardt, T.

    2017-12-01

    LANDFIRE, also known as the Landscape Fire and Resource Management Planning Tools Program, is a vegetation, fire, and fuel characteristic data creation program managed by both the U.S. Department of Agriculture Forest Service and the U.S. Department of the Interior with involvement from The Nature Conservancy. LANDFIRE represents the first and only complete, nationally consistent collection of over 20 geo-spatial layers (e.g., vegetation type and structure, fuels, fire regimes), databases, and ecological models that can be used across multiple disciplines to support cross-boundary planning, management, and operations across all lands of the United States and insular areas. Since 2004, LANDFIRE has produced comprehensive, consistent, and scientifically based suites of mapped products and associated databases for the United States and affiliated territories. These products depict the nation's major ecosystems and wildlife habitats. Over a decade has passed since the development of the first LANDFIRE base map, and an overhaul of the data products, i.e., a "Remap", is needed to maintain their functionality and relevance. To prepare for Remap production LANDFIRE has invested in a prototyping phase that focused on exploring various input data sources and new modeling and mapping techniques. While still grounded in a solid base consisting of Landsat imagery and high-quality field observations, the prototyping efforts explored different image compositing techniques, the integration of lidar data, modeling approaches as well as other factors that will inform Remap production. Several of these various research efforts are highlighted here and are currently being integrated into an end-to-end data processing flow that will drive the Remap production. The current Remap prototype effort has focused on several study areas throughout CONUS, with additional studies anticipated for Alaska, Hawaii and the territories. The LANDFIRE Remap effort is expected to take three to four years

  4. Subsidence Reversal in a Re-established Wetland in the Sacramento-San Joaquin Delta, California, USA

    Directory of Open Access Journals (Sweden)

    Robin L. Miller

    2008-10-01

    Full Text Available The stability of levees in the Sacramento-San Joaquin Delta is threatened by continued subsidence of Delta peat islands. Up to 6 meters of land-surface elevation has been lost in the 150 years since Delta marshes were leveed and drained, primarily from oxidation of peat soils. Flooding subsided peat islands halts peat oxidation by creating anoxic soils, but net accumulation of new material in restored wetlands is required to recover land-surface elevations. We investigated the subsidence reversal potential of two 3 hectare, permanently flooded, impounded wetlands re-established on a deeply subsided field on Twitchell Island. The shallower wetland (design water depth 25 cm was almost completely colonized by dense emergent marsh vegetation within two years; whereas, the deeper wetland (design water depth 55 cm which developed spatially variable depths as a result of heterogeneous colonization by emergent vegetation, still had some areas remaining as open water after nine years. Changes in land-surface elevation were quantified using repeated sedimentation-erosion table measurements. New material accumulating in the wetlands was sampled by coring. Land-surface elevations increased by an average of 4 cm/yr in both wetlands from 1997 to 2006; however, the rates at different sites in the wetlands ranged from -0.5 to +9.2 cm/yr. Open water areas of the deeper wetland without emergent vegetation had the lowest rates of land-surface elevation gain. The greatest rates occurred in areas of the deeper wetland most isolated from the river water inlets, with dense stands of emergent marsh vegetation (tules and cattails. Vegetated areas of the deeper wetland in the transition zones between open water and mature emergent stands had intermediate rates of land-surface gain, as did the entire shallower wetland. These results suggest that the dominant component contributing to land-surface elevation gain in these wetlands was accumulation of organic matter, rather

  5. Re-establishing safer medical-circumcision-integrated initiation ceremonies for HIV prevention in a rural setting in Papua New Guinea. A multi-method acceptability study.

    Directory of Open Access Journals (Sweden)

    Clement Morris Manineng

    Full Text Available Efforts to stem the spread of Human Immunodeficiency Virus (HIV in Papua New Guinea (PNG are hampered by multiple interrelated factors including limited health services, extreme diversities in culture and language and highly prevalent gender inequity, domestic violence and poverty. In the rural district of Yangoru-Saussia, a revival of previously ceased male initiation ceremonies (MICs is being considered for a comprehensive approach to HIV prevention. In this study, we explore the local acceptability of this undertaking including replacing traditional penile cutting practices with medical male circumcision (MMC.A multi-method study comprising three phases. Phase one, focus group discussions with male elders to explore locally appropriate approaches to HIV prevention; Phase two, interviews and a cross-sectional survey with community men and women to assess views on MICs that include MMC for HIV prevention; Phase three, interviews with cultural leaders and a cross sectional survey to assess the acceptability of replacing traditional penile bleeding with MMC.Cultural leaders expressed that re-establishing MICs was locally appropriate for HIV prevention given the focus on character building and cultural preservation. Most surveyed participants (81.5% supported re-establishing MICs and 92.2% supported adapting MICs with MMC. Changes to penile bleeding emerged as a contentious and contested issue given its cultural significance in symbolizing initiates' transition from childhood to adulthood. Participants were concerned about potential clash with modern education, introduced religious beliefs and limited government support in leadership and funding.Most people in this study in Yangoru-Saussia support re-establishing MICs and replacing traditional penile bleeding with MMC. This culturally-sensitive alignment of MMC (and HIV prevention with revived MICs responds to a national health priority in PNG and acts as an example of providing culturally

  6. Breakup and reestablishment of the armour layer in a large gravel-bed river below dams: The lower Ebro

    Science.gov (United States)

    Vericat, Damia; Batalla, Ramon J.; Garcia, Celso

    2006-06-01

    Changes in armour layer during floods under supply limited conditions are little known. This paper describes the breakup and the reestablishment of the bed armour layer in the regulated gravel-bed Ebro River during a flooding period. The study was conducted over a 28-km study reach from 2002 to 2004. The surface, subsurface and bed load grain size distribution constitute the bases for the analysis of bed-armouring dynamics. The results indicate that the magnitude of floods controlled the degree of armouring of the river bed. The initial mean armouring ratio was 2.3, with maximum values reaching 4.4. Floods in the winter of 2002-2003 ( Q8) caused the breakup of the armour layer in several sections. This resulted in the erratic bed load pattern observed during the December 2002 flushing flow and in the increase in bed load transport during successive events. Most grain size classes were entrained and transported, causing river bed incision. The mean armouring ratio decreased to 1.9. In contrast, during low magnitude floods in 2003-2004 ( Q2), the coarsest fractions (64 mm) did not take part in the bed load while finer particles were winnowed, thus surface deposits coarsened. As a result, the armour layer was reestablished (i.e., the mean armouring ratio increased to 2.3), and the supply of subsurface sediment decreased. The supply and transport of bed material appear to be in balance in the river reach immediately below the dam. In contrast, the transport of medium and finer size classes in the downstream reaches was higher than their supply from upstream, a phenomenon that progressively reduced their availability in the river bed surface, hence the armour layer reworking.

  7. U-10Mo Baseline Fuel Fabrication Process Description

    Energy Technology Data Exchange (ETDEWEB)

    Hubbard, Lance R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Arendt, Christina L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dye, Daniel F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Clayton, Christopher K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lerchen, Megan E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lombardo, Nicholas J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zacher, Alan H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-09-27

    This document provides a description of the U.S. High Power Research Reactor (USHPRR) low-enriched uranium (LEU) fuel fabrication process. This document is intended to be used in conjunction with the baseline process flow diagram (PFD) presented in Appendix A. The baseline PFD is used to document the fabrication process, communicate gaps in technology or manufacturing capabilities, convey alternatives under consideration, and as the basis for a dynamic simulation model of the fabrication process. The simulation model allows for the assessment of production rates, costs, and manufacturing requirements (manpower, fabrication space, numbers and types of equipment, etc.) throughout the lifecycle of the USHPRR program. This document, along with the accompanying PFD, is updated regularly

  8. ecotaxonomic baseline evaluation of the plant species in a ...

    African Journals Online (AJOL)

    Admin

    plant species of medicinal and other economic values. The investigation was ... A total of 41 and 24 representative ... INTRODUCTION. Baseline .... at 100m interval, involving a total of 15 sampling locations .... explained by factors such as climate, productivity and ... encouraging the: Maintenance of traditional tree species.

  9. Classification of baseline toxicants for QSAR predictions to replace fish acute toxicity studies.

    Science.gov (United States)

    Nendza, Monika; Müller, Martin; Wenzel, Andrea

    2017-03-22

    Fish acute toxicity studies are required for environmental hazard and risk assessment of chemicals by national and international legislations such as REACH, the regulations of plant protection products and biocidal products, or the GHS (globally harmonised system) for classification and labelling of chemicals. Alternative methods like QSARs (quantitative structure-activity relationships) can replace many ecotoxicity tests. However, complete substitution of in vivo animal tests by in silico methods may not be realistic. For the so-called baseline toxicants, it is possible to predict the fish acute toxicity with sufficient accuracy from log K ow and, hence, valid QSARs can replace in vivo testing. In contrast, excess toxicants and chemicals not reliably classified as baseline toxicants require further in silico, in vitro or in vivo assessments. Thus, the critical task is to discriminate between baseline and excess toxicants. For fish acute toxicity, we derived a scheme based on structural alerts and physicochemical property thresholds to classify chemicals as either baseline toxicants (=predictable by QSARs) or as potential excess toxicants (=not predictable by baseline QSARs). The step-wise approach identifies baseline toxicants (true negatives) in a precautionary way to avoid false negative predictions. Therefore, a certain fraction of false positives can be tolerated, i.e. baseline toxicants without specific effects that may be tested instead of predicted. Application of the classification scheme to a new heterogeneous dataset for diverse fish species results in 40% baseline toxicants, 24% excess toxicants and 36% compounds not classified. Thus, we can conclude that replacing about half of the fish acute toxicity tests by QSAR predictions is realistic to be achieved in the short-term. The long-term goals are classification criteria also for further groups of toxicants and to replace as many in vivo fish acute toxicity tests as possible with valid QSAR

  10. Fragrance mix II in the baseline series contributes significantly to detection of fragrance allergy

    DEFF Research Database (Denmark)

    Heisterberg, Maria V; Andersen, Klaus E; Avnstorp, Christian

    2010-01-01

    Fragrance mix II (FM II) is a relatively new screening marker for fragrance contact allergy. It was introduced in the patch test baseline series in Denmark in 2005 and contains six different fragrance chemicals commonly present in cosmetic products and which are known allergens.......Fragrance mix II (FM II) is a relatively new screening marker for fragrance contact allergy. It was introduced in the patch test baseline series in Denmark in 2005 and contains six different fragrance chemicals commonly present in cosmetic products and which are known allergens....

  11. Delineation of a Re-establishing Drainage Network Using SPOT and Landsat Images

    Science.gov (United States)

    Bailey, J. E.; Self, S.; Mouginis-Mark, P. J.

    2008-12-01

    The 1991 eruption of Mt. Pinatubo, The Philippines, provided a unique opportunity to study the effects on the landscape of a large eruption in part because it took place after the advent of regular satellite-based observations. The eruption formed one large (>100km2) ignimbrite sheet, with over 70% of the total deposit deposited in three primary drainage basins to the west of the volcano. High-resolution (20 m/pixel) satellite images, showing the western drainage basins and surrounding region both before and after the eruption were used to observe the re-establishment and evolution of drainage networks on the newly emplaced ignimbrite sheet. Changes in the drainage networks were delineated from a time series of SPOT (Satellite Pour l'Observation de la Terre) and Landsat multi-spectral satellite images. The analysis of which was supplemented by ground- based observations. The satellite images showed that the blue prints for the new drainage systems were established early (within days of the eruption) and at a large-scale followed the pre-eruption pattern. However, the images also illustrated the ephemeral nature of many channels due to the influence of secondary pyroclastic flows, lahar- dammed lake breakouts, stream piracy and shifts due to erosion. Characteristics of the defined drainage networks were used to infer the relative influence on the lahar hazard within each drainage basin.

  12. End-Users' Product Preference Across Three Multipurpose Prevention Technology Delivery Forms: Baseline Results from Young Women in Kenya and South Africa.

    Science.gov (United States)

    Weinrib, Rachel; Minnis, Alexandra; Agot, Kawango; Ahmed, Khatija; Owino, Fred; Manenzhe, Kgahlisho; Cheng, Helen; van der Straten, Ariane

    2018-01-01

    A multipurpose prevention technology (MPT) that combines HIV and pregnancy prevention is a promising women's health intervention, particularly for young women. However, little is known about the drivers of acceptability and product choice for MPTs in this population. This paper explores approval ratings and stated choice across three different MPT delivery forms among potential end-users. The Trio Study was a mixed-methods study in women ages 18-30 that examined acceptability of three MPT delivery forms: oral tablets, injections, and vaginal ring. Approval ratings and stated choice among the products was collected at baseline. Factors influencing stated product choice were explored using multivariable multinomial logistic regression. The majority (62%) of women in Trio stated they would choose injections, 27% would choose tablets and 11% would choose the ring. Significant predictors of choice included past experience with similar contraceptive delivery forms, age, and citing frequency of use as important. Ring choice was higher for older (25-30) women than for younger (18-24) women (aRR = 3.1; p < 0.05). These results highlight the importance of familiarity in MPT product choice of potential for variations in MPT preference by age.

  13. Program Baseline Change Control Procedure

    International Nuclear Information System (INIS)

    1993-02-01

    This procedure establishes the responsibilities and process for approving initial issues of and changes to the technical, cost, and schedule baselines, and selected management documents developed by the Office of Civilian Radioactive Waste Management (OCRWM) for the Civilian Radioactive Waste Management System. This procedure implements the OCRWM Baseline Management Plan and DOE Order 4700.1, Chg 1. It streamlines the change control process to enhance integration, accountability, and traceability of Level 0 and Level I decisions through standardized Baseline Change Proposal (BCP) forms to be used by the Level 0, 1, 2, and 3 Baseline Change Control Boards (BCCBs) and to be tracked in the OCRWM-wide Configuration Information System (CIS) Database.This procedure applies to all technical, cost, and schedule baselines controlled by the Energy System Acquisition Advisory Board (ESAAB) BCCB (Level 0) and, OCRWM Program Baseline Control Board (PBCCB) (Level 1). All baseline BCPs initiated by Level 2 or lower BCCBs, which require approval from ESAAB or PBCCB, shall be processed in accordance with this procedure. This procedure also applies to all Program-level management documents controlled by the OCRWM PBCCB

  14. Biocrust re-establishment trials demonstrate beneficial prospects for mine site rehabilitation in semi-arid landscapes of Australia

    Science.gov (United States)

    Williams, Wendy; Williams, Stephen; Galea, Vic

    2015-04-01

    Biocrusts live at the interface between the atmosphere and the soil; powered by photosynthesis they strongly influence a range of soil micro-processes. At Jacinth-Ambrosia mine site, on the edge of the Nullarbor Plain (South Australia), biocrusts are a significant component of the semi-arid soil ecosystem and comprised mainly of cyanobacteria, lichens and mosses. Cyanobacteria directly contribute to soil surface stabilisation, regulation of soil moisture and, provide a biogeochemical pathway for carbon and nitrogen fertilisation. Following disturbance, rehabilitation processes are underpinned by early soil stabilisation that can be facilitated by physical crusts or bio-active crusts in which cyanobacteria are ideal soil surface colonisers. Biocrust growth trials were carried out in autumn and winter (2012) to test the re-establishment phases of highly disturbed topsoil associated with mine site operations. The substrate material originated from shallow calcareous sandy loam typically found in chenopod shrublands. The biocrust-rich substrates (1-5 cm) were crushed (biocrush) or fine sieved followed by an application of concentrated cyanobacterial inoculum. Each treatment comprised four replicated plots that were natural or moisture assisted (using subsurface mats). After initial saturation equal amounts of water were applied for 30 days at which time half of all of the plots were enclosed with plastic to increase humidity. From 30-60 days water was added as required and from 60-180 days all treatments were uncovered and subjected periodic wet-dry cycles. At 180 days diverse biocrusts had re-established across the majority of the treatments, incorporating a mix of cyanobacterial functional groups that were adapted to surface and subsurface habitats. There were no clear trends in diversity and abundance. Overall, the moisture assisted biocrush and sieved biocrush appeared to have 80% cyanobacterial diversity in common. Differences were found between the surface and

  15. Melatonin confers plant tolerance against cadmium stress via the decrease of cadmium accumulation and reestablishment of microRNA-mediated redox homeostasis.

    Science.gov (United States)

    Gu, Quan; Chen, Ziping; Yu, Xiuli; Cui, Weiti; Pan, Jincheng; Zhao, Gan; Xu, Sheng; Wang, Ren; Shen, Wenbiao

    2017-08-01

    Although melatonin-alleviated cadmium (Cd) toxicity both in animals and plants have been well studied, little is known about its regulatory mechanisms in plants. Here, we discovered that Cd stress stimulated the production of endogenous melatonin in alfalfa seedling root tissues. The pretreatment with exogenous melatonin not only increased melatonin content, but also alleviated Cd-induced seedling growth inhibition. The melatonin-rich transgenic Arabidopsis plants overexpressing alfalfa SNAT (a melatonin synthetic gene) exhibited more tolerance than wild-type plants under Cd conditions. Cd content was also reduced in root tissues. In comparison with Cd stress alone, ABC transporter and PCR2 transcripts in alfalfa seedlings, PDR8 and HMA4 in Arabidopsis, were up-regulated by melatonin. By contrast, Nramp6 transcripts were down-regulated. Changes in above transporters were correlated with the less accumulation of Cd. Additionally Cd-triggered redox imbalance was improved by melatonin. These could be supported by the changes of the Cu/Zn Superoxide Dismutase gene regulated by miR398a and miR398b. Histochemical staining, laser scanning confocal microscope, and H 2 O 2 contents analyses showed the similar tendencies. Taking together, we clearly suggested that melatonin enhanced Cd tolerance via decreasing cadmium accumulation and reestablishing the microRNAs-mediated redox homeostasis. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Program reference schedule baseline

    International Nuclear Information System (INIS)

    1986-07-01

    This Program Reference Schedule Baseline (PRSB) provides the baseline Program-level milestones and associated schedules for the Civilian Radioactive Waste Management Program. It integrates all Program-level schedule-related activities. This schedule baseline will be used by the Director, Office of Civilian Radioactive Waste Management (OCRWM), and his staff to monitor compliance with Program objectives. Chapter 1 includes brief discussions concerning the relationship of the PRSB to the Program Reference Cost Baseline (PRCB), the Mission Plan, the Project Decision Schedule, the Total System Life Cycle Cost report, the Program Management Information System report, the Program Milestone Review, annual budget preparation, and system element plans. Chapter 2 includes the identification of all Level 0, or Program-level, milestones, while Chapter 3 presents and discusses the critical path schedules that correspond to those Level 0 milestones

  17. Development of a Soil Organic Carbon Baseline for Otjozondjupa, Namibia

    NARCIS (Netherlands)

    Nijbroek, R.; Kempen, B.; Mutua, J.; Soderstrom, M.; Piikki, K.; Hengari, S.; Andreas, A.

    2017-01-01

    Land Degradation Neutrality (LDN) has been piloted in 14 countries and will be scaled up to over 120 countries. As a LDN pilot country, Namibia developed sub-national LDN baselines in Otjozondjupa Region. In addition to the three LDN indicators (soil organic carbon, land productivity and land cover

  18. Tank waste remediation system retrieval and disposal mission initial updated baseline summary

    International Nuclear Information System (INIS)

    Swita, W.R.

    1998-01-01

    This document provides a summary of the Tank Waste Remediation System (TWRS) Retrieval and Disposal Mission Initial Updated Baseline (scope, schedule, and cost), developed to demonstrate Readiness-to-Proceed (RTP) in support of the TWRS Phase 1B mission. This Updated Baseline is the proposed TWRS plan to execute and measure the mission work scope. This document and other supporting data demonstrate that the TWRS Project Hanford Management Contract (PHMC) team is prepared to fully support Phase 1B by executing the following scope, schedule, and cost baseline activities: Deliver the specified initial low-activity waste (LAW) and high-level waste (HLW) feed batches in a consistent, safe, and reliable manner to support private contractors' operations starting in June 2002; Deliver specified subsequent LAW and HLW feed batches during Phase 1B in a consistent, safe, and reliable manner; Provide for the interim storage of immobilized HLW (IHLW) products and the disposal of immobilized LAW (ILAW) products generated by the private contractors; Provide for disposal of byproduct wastes generated by the private contractors; and Provide the infrastructure to support construction and operations of the private contractors' facilities

  19. Technical baseline description for in situ vitrification laboratory test equipment

    International Nuclear Information System (INIS)

    Beard, K.V.; Bonnenberg, R.W.; Watson, L.R.

    1991-09-01

    IN situ vitrification (ISV) has been identified as possible waste treatment technology. ISV was developed by Pacific Northwest Laboratory (PNL), Richland, Washington, as a thermal treatment process to treat contaminated soils in place. The process, which electrically melts and dissolves soils and associated inorganic materials, simultaneously destroys and/or removes organic contaminants while incorporating inorganic contaminants into a stable, glass-like residual product. This Technical Baseline Description has been prepared to provide high level descriptions of the design of the Laboratory Test model, including all design modifications and safety improvements made to data. Furthermore, the Technical Baseline Description provides a basic overview of the interface documents for configuration management, program management interfaces, safety, quality, and security requirements. 8 figs

  20. DairyBISS Baseline report

    NARCIS (Netherlands)

    Buizer, N.N.; Berhanu, Tinsae; Murutse, Girmay; Vugt, van S.M.

    2015-01-01

    This baseline report of the Dairy Business Information Service and Support (DairyBISS) project presents the findings of a baseline survey among 103 commercial farms and 31 firms and advisors working in the dairy value chain. Additional results from the survey among commercial dairy farms are

  1. Baseline rationing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Moreno-Ternero, Juan D.; Østerdal, Lars Peter Raahave

    The standard problem of adjudicating conflicting claims describes a situation in which a given amount of a divisible good has to be allocated among agents who hold claims against it exceeding the available amount. This paper considers more general rationing problems in which, in addition to claims...... to international protocols for the reduction of greenhouse emissions, or water distribution in drought periods. We define a family of allocation methods for such general rationing problems - called baseline rationing rules - and provide an axiomatic characterization for it. Any baseline rationing rule within...... the family is associated with a standard rule and we show that if the latter obeys some properties reflecting principles of impartiality, priority and solidarity, the former obeys them too....

  2. CryoSat Level1b SAR/SARin: quality improvements towards BaselineC

    Science.gov (United States)

    Scagliola, Michele; Fornari, Marco; Bouzinac, Catherine; Tagliani, Nicolas; Parrinello, Tommaso

    2014-05-01

    CryoSat was launched on the 8th April 2010 and it is the first European ice mission dedicated to monitoring precise changes in the thickness of polar ice sheets and floating sea ice over a 3-year period. Cryosat carries an innovative radar altimeter called the Synthetic Aperture Interferometric Altimeter (SIRAL), that transmits pulses at a high pulse repetition frequency thus making the received echoes phase coherent and suitable for azimuth processing. This allows to reach a significantly improved along track resolution with respect to traditional pulse-width limited altimeters. CryoSat is the first altimetry mission operating in SAR mode and continuous improvement in the Level1 Instrument Processing Facility (IPF1) are being identified, tested and validated in order to improve the quality of the Level1b products. Towards the release of the BaselineC of the CryoSat Level1b SAR/SARin products, that is expected during 2014, several improvements have been identified: • a datation bias of about -0.5195 ms will be corrected • a range bias of about -0.6730 m will be corrected • the waveform length in the Level1b product will be doubled with respect to BaselineB • improved processing for 1Hz echoes to have sharper waveforms • surface sample stack weighting to filter out the single look echoes acquired at highest look angle, that results in a sharpening of the 20Hz waveforms This poster details the main improvements that are foreseen to be included in the CryoSat Level1b SAR/SARin products in BaselineC.

  3. Baseline seismic survey for the 2nd offshore methane hydrate production test in the Eastern Nankai Trough

    Science.gov (United States)

    Teranishi, Y.; Inamori, T.; Kobayashi, T.; Fujii, T.; Saeki, T.; Takahashi, H.; Kobayashi, F.

    2017-12-01

    JOGMEC carries out seismic monitoring surveys before and after the 2nd offshore methane hydrate (MH) production test in the Eastern Nankai Trough and evaluates MH dissociation behavior from the time-lapse seismic response. In 2016, JOGMEC deployed Ocean Bottom Cable (OBC) system provided by OCC in the Daini Atsumi Knoll with water depths of 900-1100 m. The main challenge of the seismic survey was to optimize the cable layout for ensuring an effective time-lapse seismic detectability while overcoming the following two issues: 1. OBC receiver lines were limited to only two lines. It was predicted that the imaging of shallow reflectors would suffer from lack of continuity and resolution due to this limitation of receiver lines. 2. The seafloor and shallow sedimentary layers including monitoring target are dipping to the Northwest direction. It was predicted that the refection points would laterally shift to up-dip direction (Southeast direction). In order to understand the impact of the issues above, the seismic survey was designed with elastic wave field simulation. The reflection seismic survey for baseline data was conducted in August 2016. A total of 70 receiver stations distributed along one cable were deployed successfully and a total of 9952 shots were fired. After the baseline seismic survey, the hydrophone and geophone vertical component datasets were processed as outlined below: designaturing, denoising, surface consistent deconvolution and surface consistent amplitude correction. High-frequency imaging with Reverse Time Migration (RTM) was introduced to these data sets. Improvements in imaging from the RTM are remarkable compared to the Kirchhoff migration and the existing Pre-stack time migration with 3D marine surface seismic data obtained and processed in 2002, especially in the following parts. The MH concentrated zone which has complex structures. Below the Bottom Simulating Reflector (BSR) which is present as a impedance-contrast boundary

  4. Baseline restoration using current conveyors

    International Nuclear Information System (INIS)

    Morgado, A.M.L.S.; Simoes, J.B.; Correia, C.M.

    1996-01-01

    A good performance of high resolution nuclear spectrometry systems, at high pulse rates, demands restoration of baseline between pulses, in order to remove rate dependent baseline shifts. This restoration is performed by circuits named baseline restorers (BLRs) which also remove low frequency noise, such as power supply hum and detector microphonics. This paper presents simple circuits for baseline restoration based on a commercial current conveyor (CCII01). Tests were performed, on two circuits, with periodic trapezoidal shaped pulses in order to measure the baseline restoration for several pulse rates and restorer duty cycles. For the current conveyor based Robinson restorer, the peak shift was less than 10 mV, for duty cycles up to 60%, at high pulse rates. Duty cycles up to 80% were also tested, being the maximum peak shift 21 mV. The peak shift for the current conveyor based Grubic restorer was also measured. The maximum value found was 30 mV at 82% duty cycle. Keeping the duty cycle below 60% improves greatly the restorer performance. The ability of both baseline restorer architectures to reject low frequency modulation is also measured, with good results on both circuits

  5. Large short-baseline νμ disappearance

    International Nuclear Information System (INIS)

    Giunti, Carlo; Laveder, Marco

    2011-01-01

    We analyze the LSND, KARMEN, and MiniBooNE data on short-baseline ν μ →ν e oscillations and the data on short-baseline ν e disappearance obtained in the Bugey-3 and CHOOZ reactor experiments in the framework of 3+1 antineutrino mixing, taking into account the MINOS observation of long-baseline ν μ disappearance and the KamLAND observation of very-long-baseline ν e disappearance. We show that the fit of the data implies that the short-baseline disappearance of ν μ is relatively large. We obtain a prediction of an effective amplitude sin 2 2θ μμ > or approx. 0.1 for short-baseline ν μ disappearance generated by 0.2 2 2 , which could be measured in future experiments.

  6. TAPIR--Finnish national geochemical baseline database.

    Science.gov (United States)

    Jarva, Jaana; Tarvainen, Timo; Reinikainen, Jussi; Eklund, Mikael

    2010-09-15

    In Finland, a Government Decree on the Assessment of Soil Contamination and Remediation Needs has generated a need for reliable and readily accessible data on geochemical baseline concentrations in Finnish soils. According to the Decree, baseline concentrations, referring both to the natural geological background concentrations and the diffuse anthropogenic input of substances, shall be taken into account in the soil contamination assessment process. This baseline information is provided in a national geochemical baseline database, TAPIR, that is publicly available via the Internet. Geochemical provinces with elevated baseline concentrations were delineated to provide regional geochemical baseline values. The nationwide geochemical datasets were used to divide Finland into geochemical provinces. Several metals (Co, Cr, Cu, Ni, V, and Zn) showed anomalous concentrations in seven regions that were defined as metal provinces. Arsenic did not follow a similar distribution to any other elements, and four arsenic provinces were separately determined. Nationwide geochemical datasets were not available for some other important elements such as Cd and Pb. Although these elements are included in the TAPIR system, their distribution does not necessarily follow the ones pre-defined for metal and arsenic provinces. Regional geochemical baseline values, presented as upper limit of geochemical variation within the region, can be used as trigger values to assess potential soil contamination. Baseline values have also been used to determine upper and lower guideline values that must be taken into account as a tool in basic risk assessment. If regional geochemical baseline values are available, the national guideline values prescribed in the Decree based on ecological risks can be modified accordingly. The national geochemical baseline database provides scientifically sound, easily accessible and generally accepted information on the baseline values, and it can be used in various

  7. Dietary and physical activity behaviors related to obesity-specific quality of life and work productivity: baseline results from a worksite trial

    Science.gov (United States)

    Cash, Stephanie Whisnant; Beresford, Shirley A.A; Henderson, Jo Ann; McTiernan, Anne; Xiao, Liren; Wang, C.Y.; Patrick, Donald L.

    2012-01-01

    Obesity is associated with impaired health-related quality of life (QoL) and reduced productivity; less is known about the effect of dietary factors. This study investigated how dietary behaviors, physical activity, and Body Mass Index (BMI) relate to weight-specific QoL and work productivity. The study was conducted in 31 small blue-collar and service industry worksites in Seattle. Participants were 747 employees (33.5% non-White). Measures included self-reported servings of fruits and vegetables, dietary behaviors such as fast food consumption, Godin free-time physical activity scores, measured height and weight, Obesity and Weight Loss Quality of Life (OWLQOL) scores, and Work Limitations Questionnaire (WLQ) scores. Baseline data were analyzed using linear mixed models separately for men (n=348) and women (n=399), since gender modified the effects. BMI was negatively associated with OWLQOL in both women (pincrease in BMI was 30% (95% CI: 25%, 44%) for women and 14% (95% CI: 10%, 17%) for men. BMI was positively associated with productivity loss only in women (exp(slope)=1.46, 95% CI: 1.02, 2.11, p=0.04). Eating while doing another activity was negatively associated with OWLQOL scores in men (p=0.0006, independent of BMI) and with productivity in women (p=0.04, effect diminished when adjusting for BMI). Fast food meals were associated with decreased productivity for men (p=0.038, independent of BMI). Results suggest the obesogenic dietary behaviors and higher BMI are associated with decreased QoL and productivity variously in women and men. PMID:22142517

  8. Environmental baselines: preparing for shale gas in the UK

    Science.gov (United States)

    Bloomfield, John; Manamsa, Katya; Bell, Rachel; Darling, George; Dochartaigh, Brighid O.; Stuart, Marianne; Ward, Rob

    2014-05-01

    Groundwater is a vital source of freshwater in the UK. It provides almost 30% of public water supply on average, but locally, for example in south-east England, it is constitutes nearly 90% of public supply. In addition to public supply, groundwater has a number of other uses including agriculture, industry, and food and drink production. It is also vital for maintaining river flows especially during dry periods and so is essential for maintaining ecosystem health. Recently, there have been concerns expressed about the potential impacts of shale gas development on groundwater. The UK has abundant shales and clays which are currently the focus of considerable interest and there is active research into their characterisation, resource evaluation and exploitation risks. The British Geological Survey (BGS) is undertaking research to provide information to address some of the environmental concerns related to the potential impacts of shale gas development on groundwater resources and quality. The aim of much of this initial work is to establish environmental baselines, such as a baseline survey of methane occurrence in groundwater (National methane baseline study) and the spatial relationships between potential sources and groundwater receptors (iHydrogeology project), prior to any shale gas exploration and development. The poster describes these two baseline studies and presents preliminary findings. BGS are currently undertaking a national survey of baseline methane concentrations in groundwater across the UK. This work will enable any potential future changes in methane in groundwater associated with shale gas development to be assessed. Measurements of methane in potable water from the Cretaceous, Jurassic and Triassic carbonate and sandstone aquifers are variable and reveal methane concentrations of up to 500 micrograms per litre, but the mean value is relatively low at documented in the range 2km. The geological modelling process will be presented and discussed

  9. Pinellas Plant Environmental Baseline Report

    Energy Technology Data Exchange (ETDEWEB)

    1997-06-01

    The Pinellas Plant has been part of the Department of Energy`s (DOE) nuclear weapons complex since the plant opened in 1957. In March 1995, the DOE sold the Pinellas Plant to the Pinellas County Industry Council (PCIC). DOE has leased back a large portion of the plant site to facilitate transition to alternate use and safe shutdown. The current mission is to achieve a safe transition of the facility from defense production and prepare the site for alternative uses as a community resource for economic development. Toward that effort, the Pinellas Plant Environmental Baseline Report (EBR) discusses the current and past environmental conditions of the plant site. Information for the EBR is obtained from plant records. Historical process and chemical usage information for each area is reviewed during area characterizations.

  10. 40 CFR 1042.825 - Baseline determination.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Baseline determination. 1042.825... Provisions for Remanufactured Marine Engines § 1042.825 Baseline determination. (a) For the purpose of this... not valid. (f) Use good engineering judgment for all aspects of the baseline determination. We may...

  11. Dietary and physical activity behaviours related to obesity-specific quality of life and work productivity: baseline results from a worksite trial.

    Science.gov (United States)

    Cash, Stephanie Whisnant; Beresford, Shirley A A; Henderson, Jo Ann; McTiernan, Anne; Xiao, Liren; Wang, C Y; Patrick, Donald L

    2012-09-28

    Obesity is associated with impaired health-related quality of life (QOL) and reduced productivity; less is known about the effect of dietary factors. The present study investigated how dietary behaviours, physical activity and BMI relate to weight-specific QOL and work productivity. The study was conducted in thirty-one small blue-collar and service industry worksites in Seattle. Participants were 747 employees (33·5 % non-White). Measures included self-reported servings of fruits and vegetables, dietary behaviours such as fast food consumption, Godin free-time physical activity scores, measured height and weight, Obesity and Weight-Loss QOL (OWLQOL) scores, and Work Limitations Questionnaire scores. Baseline data were analysed using linear mixed models separately for men (n 348) and women (n 399), since sex modified the effects. BMI was negatively associated with OWLQOL in both women (P increase in BMI was 30 (95 % CI 25, 44) % for women and 14 (95 % CI 10, 17) % for men. BMI was positively associated with productivity loss only in women (exp(slope) = 1·46, 95 % CI 1·02, 2·11, P = 0·04). Eating while doing another activity was negatively associated with OWLQOL scores in men (P = 0·0006, independent of BMI) and with productivity in women (P = 0·04, although the effect diminished when adjusting for BMI). Fast-food meals were associated with decreased productivity in men (P = 0·038, independent of BMI). The results suggest that obesogenic dietary behaviours and higher BMI are associated with decreased QOL and productivity to different degrees in women and men.

  12. Re-creating missing population baselines for Pacific reef sharks.

    Science.gov (United States)

    Nadon, Marc O; Baum, Julia K; Williams, Ivor D; McPherson, Jana M; Zgliczynski, Brian J; Richards, Benjamin L; Schroeder, Robert E; Brainard, Russell E

    2012-06-01

    Sharks and other large predators are scarce on most coral reefs, but studies of their historical ecology provide qualitative evidence that predators were once numerous in these ecosystems. Quantifying density of sharks in the absence of humans (baseline) is, however, hindered by a paucity of pertinent time-series data. Recently researchers have used underwater visual surveys, primarily of limited spatial extent or nonstandard design, to infer negative associations between reef shark abundance and human populations. We analyzed data from 1607 towed-diver surveys (>1 ha transects surveyed by observers towed behind a boat) conducted at 46 reefs in the central-western Pacific Ocean, reefs that included some of the world's most pristine coral reefs. Estimates of shark density from towed-diver surveys were substantially lower (sharks observed in towed-diver surveys and human population in models that accounted for the influence of oceanic primary productivity, sea surface temperature, reef area, and reef physical complexity. We used these models to estimate the density of sharks in the absence of humans. Densities of gray reef sharks (Carcharhinus amblyrhynchos), whitetip reef sharks (Triaenodon obesus), and the group "all reef sharks" increased substantially as human population decreased and as primary productivity and minimum sea surface temperature (or reef area, which was highly correlated with temperature) increased. Simulated baseline densities of reef sharks under the absence of humans were 1.1-2.4/ha for the main Hawaiian Islands, 1.2-2.4/ha for inhabited islands of American Samoa, and 0.9-2.1/ha for inhabited islands in the Mariana Archipelago, which suggests that density of reef sharks has declined to 3-10% of baseline levels in these areas. ©2012 Society for Conservation Biology No claim to original US government works.

  13. Oscillation Baselining and Analysis Tool

    Energy Technology Data Exchange (ETDEWEB)

    2017-03-27

    PNNL developed a new tool for oscillation analysis and baselining. This tool has been developed under a new DOE Grid Modernization Laboratory Consortium (GMLC) Project (GM0072 - “Suite of open-source applications and models for advanced synchrophasor analysis”) and it is based on the open platform for PMU analysis. The Oscillation Baselining and Analysis Tool (OBAT) performs the oscillation analysis and identifies modes of oscillations (frequency, damping, energy, and shape). The tool also does oscillation event baselining (fining correlation between oscillations characteristics and system operating conditions).

  14. A baseline survey of tiger nut ( Cyperus esculentus ) production in ...

    African Journals Online (AJOL)

    Tiger nut (Cyperus esculentus) is a minor but important crop in Ghana. In a survey conducted on the production and marketing of the crop at Aduamoa in the Kwahu South District of Ghana, it was observed that tiger nut production was predominantly the work of women, with 70 per cent of farmers being women and 30 per ...

  15. 33 CFR 2.20 - Territorial sea baseline.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Territorial sea baseline. 2.20... JURISDICTION Jurisdictional Terms § 2.20 Territorial sea baseline. Territorial sea baseline means the line.... Normally, the territorial sea baseline is the mean low water line along the coast of the United States...

  16. Heterotrophy promotes the re-establishment of photosynthate translocation in a symbiotic coral after heat stress

    Science.gov (United States)

    Tremblay, Pascale; Gori, Andrea; Maguer, Jean François; Hoogenboom, Mia; Ferrier-Pagès, Christine

    2016-12-01

    Symbiotic scleractinian corals are particularly affected by climate change stress and respond by bleaching (losing their symbiotic dinoflagellate partners). Recently, the energetic status of corals is emerging as a particularly important factor that determines the corals’ vulnerability to heat stress. However, detailed studies of coral energetic that trace the flow of carbon from symbionts to host are still sparse. The present study thus investigates the impact of heat stress on the nutritional interactions between dinoflagellates and coral Stylophora pistillata maintained under auto- and heterotrophy. First, we demonstrated that the percentage of autotrophic carbon retained in the symbionts was significantly higher during heat stress than under non-stressful conditions, in both fed and unfed colonies. This higher photosynthate retention in symbionts translated into lower rates of carbon translocation, which required the coral host to use tissue energy reserves to sustain its respiratory needs. As calcification rates were positively correlated to carbon translocation, a significant decrease in skeletal growth was observed during heat stress. This study also provides evidence that heterotrophic nutrient supply enhances the re-establishment of normal nutritional exchanges between the two symbiotic partners in the coral S. pistillata, but it did not mitigate the effects of temperature stress on coral calcification.

  17. Re-Establishment of Standard Radiation Qualities for Calibration of Dosemeter in Diagnostic Radiology - RQR Series

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Norhayati Abdullah; Mohd Firdaus Abd Rahman

    2016-01-01

    After repairing the high voltage (HV) generator for Philips MG165 X-Ray Machine, the reestablishment of the standard radiation qualities has been done at Medical Physics Calibration Laboratory to meet the IEC and IAEA standard. Standard radiation qualities are the important criteria for calibration of dosemeter in diagnostic radiology. Standard radiation qualities are defined as the added filtration needed to produce and the half value layer (HVL) of the beam for specifies x-ray tube kilo voltage (kV). For calibration of dosemeter in diagnostic radiology, standard radiation qualities RQR represent the beam incident on the patient in general radiography, fluoroscopy and dental application. The HVL were measured using PTW ion chamber of volume 1 cm"3 with PTW electrometer and aluminium filter with 99.9 % purity was used as additional filter for RQR and filter for HVL. The first establishment of standard radiation qualities was made in 2009 for the radiation qualities of RQR. The results of additional filter and 1st HVL from 2009 to 2016 will be discussed further in paper. The ratios of the measured HVL to the standard IEC HVL value for the RQR series also described in this paper. The details of the measurement and the results are described in this paper. (author)

  18. Program Baseline Change Control Board charter

    International Nuclear Information System (INIS)

    1993-02-01

    The purpose of this Charter is to establish the Program Baseline Change Control Board (PBCCB) for the Office of Civilian Radioactive Waste Management (OCRWM) Program, and to describe its organization, responsibilities, and basic methods of operation. Guidance for implementing this Charter is provided by the OCRWM Baseline Management Plan (BMP) and OCRWM Program Baseline Change Control Procedure

  19. Re-establishing an ecological discourse in the policy debate over how to value ecosystems and biodiversity.

    Science.gov (United States)

    Spash, Clive L; Aslaksen, Iulie

    2015-08-15

    In this paper we explore the discourses of ecology, environmental economics, new environmental pragmatism and social ecological economics as they relate to the value of ecosystems and biodiversity. Conceptualizing biodiversity and ecosystems as goods and services that can be represented by monetary values in policy processes is an economic discourse being increasingly championed by ecologists and conservation biologists. The latter promote a new environmental pragmatism internationally as hardwiring biodiversity and ecosystems services into finance. The approach adopts a narrow instrumentalism, denies value pluralism and incommensurability, and downplays the role of scientific knowledge. Re-establishing an ecological discourse in biodiversity policy implies a crucial role for biophysical indicators as independent policy targets, exemplified in this paper by the Nature Index for Norway. Yet, there is a recognisable need to go beyond a traditional ecological approach to one recognising the interconnections of social, ecological and economic problems. This requires reviving and relating to a range of alternative ecologically informed discourses, including an ecofeminist perspective, in order to transform the increasingly dominant and destructive relationship of humans separated from and domineering over Nature. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Establishing a store baseline during interim storage of waste packages and a review of potential technologies for base-lining

    Energy Technology Data Exchange (ETDEWEB)

    McTeer, Jennifer; Morris, Jenny; Wickham, Stephen [Galson Sciences Ltd. Oakham, Rutland (United Kingdom); Bolton, Gary [National Nuclear Laboratory Risley, Warrington (United Kingdom); McKinney, James; Morris, Darrell [Nuclear Decommissioning Authority Moor Row, Cumbria (United Kingdom); Angus, Mike [National Nuclear Laboratory Risley, Warrington (United Kingdom); Cann, Gavin; Binks, Tracey [National Nuclear Laboratory Sellafield (United Kingdom)

    2013-07-01

    Interim storage is an essential component of the waste management lifecycle, providing a safe, secure environment for waste packages awaiting final disposal. In order to be able to monitor and detect change or degradation of the waste packages, storage building or equipment, it is necessary to know the original condition of these components (the 'waste storage system'). This paper presents an approach to establishing the baseline for a waste-storage system, and provides guidance on the selection and implementation of potential base-lining technologies. The approach is made up of two sections; assessment of base-lining needs and definition of base-lining approach. During the assessment of base-lining needs a review of available monitoring data and store/package records should be undertaken (if the store is operational). Evolutionary processes (affecting safety functions), and their corresponding indicators, that can be measured to provide a baseline for the waste-storage system should then be identified in order for the most suitable indicators to be selected for base-lining. In defining the approach, identification of opportunities to collect data and constraints is undertaken before selecting the techniques for base-lining and developing a base-lining plan. Base-lining data may be used to establish that the state of the packages is consistent with the waste acceptance criteria for the storage facility and to support the interpretation of monitoring and inspection data collected during store operations. Opportunities and constraints are identified for different store and package types. Technologies that could potentially be used to measure baseline indicators are also reviewed. (authors)

  1. Hazard Baseline Downgrade Effluent Treatment Facility

    International Nuclear Information System (INIS)

    Blanchard, A.

    1998-01-01

    This Hazard Baseline Downgrade reviews the Effluent Treatment Facility, in accordance with Department of Energy Order 5480.23, WSRC11Q Facility Safety Document Manual, DOE-STD-1027-92, and DOE-EM-STD-5502-94. It provides a baseline grouping based on the chemical and radiological hazards associated with the facility. The Determination of the baseline grouping for ETF will aid in establishing the appropriate set of standards for the facility

  2. Fragrance mix II in the baseline series contributes significantly to detection of fragrance allergy

    DEFF Research Database (Denmark)

    Heisterberg, Maria S Vølund; Andersen, Klaus E.; Avnstorp, Christian

    2010-01-01

    Background: Fragrance mix II (FM II) is a relatively new screening marker for fragrance contact allergy. It was introduced in the patch test baseline series in Denmark in 2005 and contains six different fragrance chemicals commonly present in cosmetic products and which are known allergens. Aim......: To investigate the diagnostic contribution of including FM II in the baseline series by comparing it with other screening markers of fragrance allergy: fragrance mix I (FM I), Myroxylon pereirae and hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC). Method: Retrospective study of 12 302 patients consecutively...

  3. A method to establish seismic noise baselines for automated station assessment

    Science.gov (United States)

    McNamara, D.E.; Hutt, C.R.; Gee, L.S.; Benz, H.M.; Buland, R.P.

    2009-01-01

    We present a method for quantifying station noise baselines and characterizing the spectral shape of out-of-nominal noise sources. Our intent is to automate this method in order to ensure that only the highest-quality data are used in rapid earthquake products at NEIC. In addition, the station noise baselines provide a valuable tool to support the quality control of GSN and ANSS backbone data and metadata. The procedures addressed here are currently in development at the NEIC, and work is underway to understand how quickly changes from nominal can be observed and used within the NEIC processing framework. The spectral methods and software used to compute station baselines and described herein (PQLX) can be useful to both permanent and portable seismic stations operators. Applications include: general seismic station and data quality control (QC), evaluation of instrument responses, assessment of near real-time communication system performance, characterization of site cultural noise conditions, and evaluation of sensor vault design, as well as assessment of gross network capabilities (McNamara et al. 2005). Future PQLX development plans include incorporating station baselines for automated QC methods and automating station status report generation and notification based on user-defined QC parameters. The PQLX software is available through the USGS (http://earthquake. usgs.gov/research/software/pqlx.php) and IRIS (http://www.iris.edu/software/ pqlx/).

  4. Progress toward interrupting wild poliovirus circulation in countries with reestablished transmission--Africa, 2009-2010.

    Science.gov (United States)

    2011-03-18

    Through efforts of the Global Polio Eradication Initiative (GPEI), begun in 1988, indigenous transmission of wild poliovirus (WPV) had been interrupted in all but four countries (Afghanistan, Pakistan, India, and Nigeria) by 2006. Since 2002, a total of 39 previously polio-free countries experienced outbreaks following importation of WPV of Indian or Nigerian origin. Most outbreaks were stopped 12 months following importation before 2009. A key milestone of the GPEI 2010-2012 strategic plan was to interrupt WPV transmission in these African countries with reestablished transmission by the end of 2010. As of March 8, 2011, the milestone appeared to be on track only in Sudan. In Sudan, WPV type 1 (WPV1) was introduced in 2004, but no cases were detected for a 31-month period during 2005-2008. When resurgence occurred in 2008, surveillance and eradication efforts were enhanced, and no case has been detected since June 2009. In Chad, WPV type 3 (WPV3) transmission has persisted since 2007, although undetected for 7 months in 2010. In Angola, WPV1 circulation has persisted following importation in 2007, and became more widespread in 2010, with subsequent importations into DRC and Republic of the Congo (ROC). In DRC, WPV1 circulation has persisted since introduction in 2006. Achieving polio eradication depends on stopping WPV transmission in the four endemic countries and overcoming substantial, ongoing programmatic weaknesses in Chad, Angola, and DRC.

  5. Renewable Diesel from Algal Lipids: An Integrated Baseline for Cost, Emissions, and Resource Potential from a Harmonized Model

    Energy Technology Data Exchange (ETDEWEB)

    Davis, R.; Fishman, D.; Frank, E. D.; Wigmosta, M. S.; Aden, A.; Coleman, A. M.; Pienkos, P. T.; Skaggs, R. J.; Venteris, E. R.; Wang, M. Q.

    2012-06-01

    The U.S. Department of Energy's Biomass Program has begun an initiative to obtain consistent quantitative metrics for algal biofuel production to establish an 'integrated baseline' by harmonizing and combining the Program's national resource assessment (RA), techno-economic analysis (TEA), and life-cycle analysis (LCA) models. The baseline attempts to represent a plausible near-term production scenario with freshwater microalgae growth, extraction of lipids, and conversion via hydroprocessing to produce a renewable diesel (RD) blendstock. Differences in the prior TEA and LCA models were reconciled (harmonized) and the RA model was used to prioritize and select the most favorable consortium of sites that supports production of 5 billion gallons per year of RD. Aligning the TEA and LCA models produced slightly higher costs and emissions compared to the pre-harmonized results. However, after then applying the productivities predicted by the RA model (13 g/m2/d on annual average vs. 25 g/m2/d in the original models), the integrated baseline resulted in markedly higher costs and emissions. The relationship between performance (cost and emissions) and either productivity or lipid fraction was found to be non-linear, and important implications on the TEA and LCA results were observed after introducing seasonal variability from the RA model. Increasing productivity and lipid fraction alone was insufficient to achieve cost and emission targets; however, combined with lower energy, less expensive alternative technology scenarios, emissions and costs were substantially reduced.

  6. Forest baseline and deforestation map of the Dominican Republic through the analysis of time series of MODIS data

    Directory of Open Access Journals (Sweden)

    Florencia Sangermano

    2015-09-01

    Full Text Available Deforestation is one of the major threats to habitats in the Dominican Republic. In this work we present a forest baseline for the year 2000 and a deforestation map for the year 2011. Maps were derived from Moderate Resolution Imaging Radiometer (MODIS products at 250 m resolution. The vegetation continuous fields product (MOD44B for the year 2000 was used to produce the forest baseline, while the vegetation indices product (MOD13Q1 was used to detect change between 2000 and 2011. Major findings based on the data presented here are reported in the manuscript “Habitat suitability and protection status of four species of amphibians in the Dominican Republic” (Sangermano et al., Appl. Geogr., [7].63, 2015, 55–65

  7. [Calculation on ecological security baseline based on the ecosystem services value and the food security].

    Science.gov (United States)

    He, Ling; Jia, Qi-jian; Li, Chao; Xu, Hao

    2016-01-01

    The rapid development of coastal economy in Hebei Province caused rapid transition of coastal land use structure, which has threatened land ecological security. Therefore, calculating ecosystem service value of land use and exploring ecological security baseline can provide the basis for regional ecological protection and rehabilitation. Taking Huanghua, a city in the southeast of Hebei Province, as an example, this study explored the joint point, joint path and joint method between ecological security and food security, and then calculated the ecological security baseline of Huanghua City based on the ecosystem service value and the food safety standard. The results showed that ecosystem service value of per unit area from maximum to minimum were in this order: wetland, water, garden, cultivated land, meadow, other land, salt pans, saline and alkaline land, constructive land. The order of contribution rates of each ecological function value from high to low was nutrient recycling, water conservation, entertainment and culture, material production, biodiversity maintenance, gas regulation, climate regulation and environmental purification. The security baseline of grain production was 0.21 kg · m⁻², the security baseline of grain output value was 0.41 yuan · m⁻², the baseline of ecosystem service value was 21.58 yuan · m⁻², and the total of ecosystem service value in the research area was 4.244 billion yuan. In 2081 the ecological security will reach the bottom line and the ecological system, in which human is the subject, will be on the verge of collapse. According to the ecological security status, Huanghua can be divided into 4 zones, i.e., ecological core protection zone, ecological buffer zone, ecological restoration zone and human activity core zone.

  8. Beating the baseline prediction in food sales : how intelligent an intelligent predictor is?

    NARCIS (Netherlands)

    Zliobaite, I.; Bakker, J.; Pechenizkiy, M.

    2012-01-01

    Sales prediction is an essential part of stock planning for the wholesales and retail business. It is a complex task because of the large number of factors affecting the demand. Designing an intelligent predictor that would beat a simple moving average baseline across a number of products appears to

  9. 10 CFR 850.20 - Baseline beryllium inventory.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Baseline beryllium inventory. 850.20 Section 850.20 Energy... Baseline beryllium inventory. (a) The responsible employer must develop a baseline inventory of the... inventory, the responsible employer must: (1) Review current and historical records; (2) Interview workers...

  10. 40 CFR 80.92 - Baseline auditor requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Baseline auditor requirements. 80.92... (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Anti-Dumping § 80.92 Baseline auditor requirements. (a... determination methodology, resulting baseline fuel parameter, volume and emissions values verified by an auditor...

  11. Integrated planning: A baseline development perspective

    International Nuclear Information System (INIS)

    Clauss, L.; Chang, D.

    1994-01-01

    The FEMP Baseline establishes the basis for integrating environmental activity technical requirements with their cost and schedule elements. The result is a path forward to successfully achieving the FERMCO mission. Specific to cost management, the FEMP Baseline has been incorporate into the FERMCO Project Control System (PCS) to provide a time-phased budget plan against which contractor performance is measured with an earned value management system. The result is the Performance Measurement Baseline (PMB), an important tool for keeping cost under control

  12. Reinforced Carbon Carbon (RCC) oxidation resistant material samples - Baseline coated, and baseline coated with tetraethyl orthosilicate (TEOS) impregnation

    Science.gov (United States)

    Gantz, E. E.

    1977-01-01

    Reinforced carbon-carbon material specimens were machined from 19 and 33 ply flat panels which were fabricated and processed in accordance with the specifications and procedures accepted for the fabrication and processing of the leading edge structural subsystem (LESS) elements for the space shuttle orbiter. The specimens were then baseline coated and tetraethyl orthosilicate impregnated, as applicable, in accordance with the procedures and requirements of the appropriate LESS production specifications. Three heater bars were ATJ graphite silicon carbide coated with the Vought 'pack cementation' coating process, and three were stackpole grade 2020 graphite silicon carbide coated with the chemical vapor deposition process utilized by Vought in coating the LESS shell development program entry heater elements. Nondestructive test results are reported.

  13. Physics with a very long neutrino factory baseline

    International Nuclear Information System (INIS)

    Gandhi, Raj; Winter, Walter

    2007-01-01

    We discuss the neutrino oscillation physics of a very long neutrino factory baseline over a broad range of lengths (between 6000 km and 9000 km), centered on the 'magic baseline' (∼7500 km) where correlations with the leptonic CP phase are suppressed by matter effects. Since the magic baseline depends only on the density, we study the impact of matter density profile effects and density uncertainties over this range, and the impact of detector locations off the optimal baseline. We find that the optimal constant density describing the physics over this entire baseline range is about 5% higher than the average matter density. This implies that the magic baseline is significantly shorter than previously inferred. However, while a single detector optimization requires fine-tuning of the (very long) baseline length, its combination with a near detector at a shorter baseline is much less sensitive to the far detector location and to uncertainties in the matter density. In addition, we point out different applications of this baseline which go beyond its excellent correlation and degeneracy resolution potential. We demonstrate that such a long baseline assists in the improvement of the θ 13 precision and in the resolution of the octant degeneracy. Moreover, we show that the neutrino data from such a baseline could be used to extract the matter density along the profile up to 0.24% at 1σ for large sin 2 2θ 13 , providing a useful discriminator between different geophysical models

  14. Soy food frequency questionnaire does not correlate with baseline isoflavone levels in patients with bladder cancer.

    Science.gov (United States)

    Kolesar, Jill M; Pomplun, Marcia; Havighurst, Tom; Stublaski, Jeanne; Wollmer, Barbara; Kim, KyungMann; Tangrea, Joseph A; Parnes, Howard L; House, Margaret G; Gee, Jason; Messing, Edward; Bailey, Howard H

    2015-04-01

    The isoflavone genistein, a natural soy product with receptor tyrosine kinase-inhibiting activity, as well as phytoestrogenic and other potential anticarcinogenic effects, is being studied as an anticancer agent. Since isoflavones are commonly consumed in food products containing soy proteins, a method to control for baseline isoflavone consumption is needed. HPLC was used to evaluate baseline plasma and urine concentrations of isoflavone in fifty-four participants with bladder cancer enrolled on a phase II chemoprevention study of G-2535. The soy food frequency questionnaire was used to assess participant's baseline soy intake. The association between baseline isoflavone concentrations and intakes for genistein and daidzein was assessed by the Spearman's rank correlation coefficient. The majority of participants had no detectable genistein or daidzein in plasma at baseline. The median and range of values were 0 (0-1480) nmol/L for genistein, and 0 (0-1260) nmol/L for daidzein. In urine, the median and range of values were 91.0 (0-9030) nmol/L for genistein and 623 (0-100,000) nmol/L for daidzein. The median and range of weekly estimated genistein intake was 0 (0-236) mg/wk; the median and range of weekly estimated daidzein intake was 0 (0-114) mg/wk. There was no relationship to soy intake as measured by the food frequency questionnaire and baseline isoflavone levels in plasma or urine and the Spearman's rank correlation coefficients were not significant. The soy food frequency questionnaire did not correlate with plasma or urine concentrations of either isoflavone. Alternative methods for controlling for soy consumption, including measuring plasma and urine concentrations, in isoflavone chemoprevention trials should be considered. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  15. Development of a Soil Organic Carbon Baseline for Otjozondjupa, Namibia

    OpenAIRE

    Nijbroek, R.; Kempen, B.; Mutua, J.; Soderstrom, M.; Piikki, K.; Hengari, S.; Andreas, A.

    2017-01-01

    Land Degradation Neutrality (LDN) has been piloted in 14 countries and will be scaled up to over 120 countries. As a LDN pilot country, Namibia developed sub-national LDN baselines in Otjozondjupa Region. In addition to the three LDN indicators (soil organic carbon, land productivity and land cover change), Namibia also regards bush encroachment as an important form of land degradation. We collected 219 soil profiles and used Random Forest modelling to develop the soil organic carbon stock ba...

  16. Biofuels Baseline 2008

    Energy Technology Data Exchange (ETDEWEB)

    Hamelinck, C.; Koper, M.; Berndes, G.; Englund, O.; Diaz-Chavez, R.; Kunen, E.; Walden, D.

    2011-10-15

    The European Union is promoting the use of biofuels and other renewable energy in transport. In April 2009, the Renewable Energy Directive (2009/28/EC) was adopted that set a 10% target for renewable energy in transport in 2020. The directive sets several requirements to the sustainability of biofuels marketed in the frame of the Directive. The Commission is required to report to the European Parliament on a regular basis on a range of sustainability impacts resulting from the use of biofuels in the EU. This report serves as a baseline of information for regular monitoring on the impacts of the Directive. Chapter 2 discusses the EU biofuels market, the production and consumption of biofuels and international trade. It is derived where the feedstock for EU consumed biofuels originally come from. Chapter 3 discusses the biofuel policy framework in the EU and major third countries of supply. It looks at various policy aspects that are relevant to comply with the EU sustainability requirements. Chapter 4 discusses the environmental and social sustainability aspects associated with EU biofuels and their feedstock. Chapter 5 discusses the macro-economic effects that indirectly result from increased EU biofuels consumption, on commodity prices and land use. Chapter 6 presents country factsheets for main third countries that supplied biofuels to the EU market in 2008.

  17. The TDAQ Baseline Architecture

    CERN Multimedia

    Wickens, F J

    The Trigger-DAQ community is currently busy preparing material for the DAQ, HLT and DCS TDR. Over the last few weeks a very important step has been a series of meetings to complete agreement on the baseline architecture. An overview of the architecture indicating some of the main parameters is shown in figure 1. As reported at the ATLAS Plenary during the February ATLAS week, the main area where the baseline had not yet been agreed was around the Read-Out System (ROS) and details in the DataFlow. The agreed architecture has: Read-Out Links (ROLs) from the RODs using S-Link; Read-Out Buffers (ROB) sited near the RODs, mounted in a chassis - today assumed to be a PC, using PCI bus at least for configuration, control and monitoring. The baseline assumes data aggregation, in the ROB and/or at the output (which could either be over a bus or in the network). Optimization of the data aggregation will be made in the coming months, but the current model has each ROB card receiving input from 4 ROLs, and 3 such c...

  18. Systematic assessment of the various controversies, difficulties, and current trends in the reestablishment of lost occlusal planes in edentulous patients.

    Science.gov (United States)

    Sahoo, S; Singh, D; Raghav, D; Singh, G; Sarin, A; Kumar, P

    2014-05-01

    Accurate occlusal plane orientation is an essential factor in the fabrication of complete denture prosthesis. Over the years, it has received a number of methodologies by several researchers utilizing various anatomical landmarks however none of them is considered as perfect that could orient ideal occlusal plane. The presented literature review is an attempt to enlighten historical perspectives, pioneer researches, different controversies, difficulties and current trends for re-establishment of lost occlusal plane in edentulous patients. An extensive literature search was performed using Medline/PubMed interface and other scholarly research bibliographic databases using Medical Subject Headings. Studies describing research studies, case series and assorted clinical reports were retrieved and evaluated from 1963 to 2013. Most of the studies have suggest and evidence to consider Camper's plane for artificial orientation of occlusal plane however there is a substantial lack of genuine long term studies and authentic data that could recommend a single reliable landmark for perfect occlusal plane reorientation in a variety of cases.

  19. THE US LONG BASELINE NEUTRINO EXPERIMENT STUDY.

    Energy Technology Data Exchange (ETDEWEB)

    BISHAI,M.

    2007-08-06

    The US Long Baseline Neutrino Experiment Study was commissioned jointly by Brookhaven National Laboratory (BNL)and Fermi National Accelerator Laboratory (FNAL) to investigate the potential for future U.S. based long baseline neutrino oscillation experiments using MW class conventional neutrino beams that can be produced at FNAL. The experimental baselines are based on two possible detector locations: (1) off-axis to the existing FNAL NuMI beamline at baselines of 700 to 810 km and (2) NSF's proposed future Deep Underground Science and Engineering Laboratory (DUSEL) at baselines greater than 1000km. Two detector technologies are considered: a megaton class Water Cherenkov detector deployed deep underground at a DUSEL site, or a 100kT Liquid Argon Time-Projection Chamber (TPC) deployed on the surface at any of the proposed sites. The physics sensitivities of the proposed experiments are summarized. We find that conventional horn focused wide-band neutrino beam options from FNAL aimed at a massive detector with a baseline of > 1000km have the best sensitivity to CP violation and the neutrino mass hierarchy for values of the mixing angle {theta}{sub 13} down to 2{sup o}.

  20. Stack Characterization in CryoSat Level1b SAR/SARin Baseline C

    Science.gov (United States)

    Scagliola, Michele; Fornari, Marco; Di Giacinto, Andrea; Bouffard, Jerome; Féménias, Pierre; Parrinello, Tommaso

    2015-04-01

    CryoSat was launched on the 8th April 2010 and is the first European ice mission dedicated to the monitoring of precise changes in the thickness of polar ice sheets and floating sea ice. CryoSat is the first altimetry mission operating in SAR mode and it carries an innovative radar altimeter called the Synthetic Aperture Interferometric Altimeter (SIRAL), that transmits pulses at a high pulse repetition frequency thus making the received echoes phase coherent and suitable for azimuth processing. The current CryoSat IPF (Instrument Processing Facility), Baseline B, was released in operation in February 2012. After more than 2 years of development, the release in operations of the Baseline C is expected in the first half of 2015. It is worth recalling here that the CryoSat SAR/SARin IPF1 generates 20Hz waveforms in correspondence of an approximately equally spaced set of ground locations on the Earth surface, i.e. surface samples, and that a surface sample gathers a collection of single-look echoes coming from the processed bursts during the time of visibility. Thus, for a given surface sample, the stack can be defined as the collection of all the single-look echoes pointing to the current surface sample, after applying all the necessary range corrections. The L1B product contains the power average of all the single-look echoes in the stack: the multi-looked L1B waveform. This reduces the data volume, while removing some information contained in the single looks, useful for characterizing the surface and modelling the L1B waveform. To recover such information, a set of parameters has been added to the L1B product: the stack characterization or beam behaviour parameters. The stack characterization, already included in previous Baselines, has been reviewed and expanded in Baseline C. This poster describes all the stack characterization parameters, detailing what they represent and how they have been computed. In details, such parameters can be summarized in: - Stack

  1. Long Baseline Observatory (LBO)

    Data.gov (United States)

    Federal Laboratory Consortium — The Long Baseline Observatory (LBO) comprises ten radio telescopes spanning 5,351 miles. It's the world's largest, sharpest, dedicated telescope array. With an eye...

  2. Hanford Site technical baseline database. Revision 1

    International Nuclear Information System (INIS)

    Porter, P.E.

    1995-01-01

    This report lists the Hanford specific files (Table 1) that make up the Hanford Site Technical Baseline Database. Table 2 includes the delta files that delineate the differences between this revision and revision 0 of the Hanford Site Technical Baseline Database. This information is being managed and maintained on the Hanford RDD-100 System, which uses the capabilities of RDD-100, a systems engineering software system of Ascent Logic Corporation (ALC). This revision of the Hanford Site Technical Baseline Database uses RDD-100 version 3.0.2.2 (see Table 3). Directories reflect those controlled by the Hanford RDD-100 System Administrator. Table 4 provides information regarding the platform. A cassette tape containing the Hanford Site Technical Baseline Database is available

  3. The effect of coracoacromial ligament excision and acromioplasty on the amount of rotator cuff force production necessary to restore intact glenohumeral biomechanics.

    Science.gov (United States)

    Budoff, Jeffrey E; Lin, Cheng-Li; Hong, Chih-Kai; Chiang, Florence L; Su, Wei-Ren

    2016-06-01

    Coracoacromial ligament (CAL) excision and acromioplasty increase superior and anterosuperior glenohumeral translation. It is unknown how much of an increase in rotator cuff force production is required to re-establish intact glenohumeral biomechanics after these surgical procedures. We hypothesized that, after CAL excision and acromioplasty, an increase in rotator cuff force production would not be necessary to reproduce the anterosuperior and superior translations of the intact specimens. Nine cadaveric shoulders were subjected to loading in the superior and anterosuperior directions in the intact state after CAL excision, acromioplasty, and recording of the translations. The rotator cuff force was then increased to normalize glenohumeral biomechanics. After CAL excision at 150 and 200 N of loading, an increase in the rotator cuff force by 25% decreased anterosuperior translation to the point where there was no significant difference from the intact specimen's translation. After acromioplasty (and CAL excision) at 150 and 200 N, an increase in the rotator cuff force of 25% and 30%, respectively, decreased superior translation to the point where there was no significant difference from the intact specimen's translation. At 150 to 200 N of loading, CAL excision and acromioplasty increase the rotator cuff force required to maintain normal glenohumeral biomechanics by 25% to 30%. After a subacromial decompression, the rotator cuff has an increased force production requirement to maintain baseline glenohumeral mechanics. Under many circumstances, in vivo force requirements may be even greater after surgical attenuation of the coracoacromial arch. Basic Science Study; Biomechanics. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. 75 FR 66748 - Notice of Baseline Filings

    Science.gov (United States)

    2010-10-29

    ...- 000] Notice of Baseline Filings October 22, 2010. ONEOK Gas Transportation, L.L.C Docket No. PR11-68... above submitted a revised baseline filing of their Statement of Operating Conditions for services...

  5. 2016 Annual Technology Baseline (ATB) - Webinar Presentation

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Wesley; Kurup, Parthiv; Hand, Maureen; Feldman, David; Sigrin, Benjamin; Lantz, Eric; Stehly, Tyler; Augustine, Chad; Turchi, Craig; Porro, Gian; O' Connor, Patrick; Waldoch, Connor

    2016-09-13

    This deck was presented for the 2016 Annual Technology Baseline Webinar. The presentation describes the Annual Technology Baseline, which is a compilation of current and future cost and performance data for electricity generation technologies.

  6. Associations between baseline allergens and polysensitization

    DEFF Research Database (Denmark)

    Carlsen, B.C.; Menne, T.; Johansen, J.D.

    2008-01-01

    Background: Identification of patients at risk of developing polysensitization is not possible at present. An association between weak sensitizers and polysensitization has been hypothesized. Objectives: To examine associations of 21 allergens in the European baseline series to polysensitization....... Patients/Methods: From a database-based study with 14 998 patients patch tested with the European baseline series between 1985 and 2005, a group of 759 (5.1%) patients were polysensitized. Odds ratios were calculated to determine the relative contribution of each allergen to polysensitization. Results...... denominator for the association between the allergens and the polysensitization was apparent, and any association, whether positive or negative, was relatively low. Based on these results, sensitization to specific baseline allergens cannot be used as risk indicators for polysensitization Udgivelsesdato: 2008...

  7. Associations between baseline allergens and polysensitization

    DEFF Research Database (Denmark)

    Carlsen, Berit Christina; Menné, Torkil; Johansen, Jeanne Duus

    2008-01-01

    BACKGROUND: Identification of patients at risk of developing polysensitization is not possible at present. An association between weak sensitizers and polysensitization has been hypothesized. OBJECTIVES: To examine associations of 21 allergens in the European baseline series to polysensitization....... PATIENTS/METHODS: From a database-based study with 14 998 patients patch tested with the European baseline series between 1985 and 2005, a group of 759 (5.1%) patients were polysensitized. Odds ratios were calculated to determine the relative contribution of each allergen to polysensitization. RESULTS...... denominator for the association between the allergens and the polysensitization was apparent, and any association, whether positive or negative, was relatively low. Based on these results, sensitization to specific baseline allergens cannot be used as risk indicators for polysensitization....

  8. TWRS technical baseline database manager definition document

    International Nuclear Information System (INIS)

    Acree, C.D.

    1997-01-01

    This document serves as a guide for using the TWRS Technical Baseline Database Management Systems Engineering (SE) support tool in performing SE activities for the Tank Waste Remediation System (TWRS). This document will provide a consistent interpretation of the relationships between the TWRS Technical Baseline Database Management software and the present TWRS SE practices. The Database Manager currently utilized is the RDD-1000 System manufactured by the Ascent Logic Corporation. In other documents, the term RDD-1000 may be used interchangeably with TWRS Technical Baseline Database Manager

  9. Business-as-Unusual: Existing policies in energy model baselines

    International Nuclear Information System (INIS)

    Strachan, Neil

    2011-01-01

    Baselines are generally accepted as a key input assumption in long-term energy modelling, but energy models have traditionally been poor on identifying baselines assumptions. Notably, transparency on the current policy content of model baselines is now especially critical as long-term climate mitigation policies have been underway for a number of years. This paper argues that the range of existing energy and emissions policies are an integral part of any long-term baseline, and hence already represent a 'with-policy' baseline, termed here a Business-as-Unusual (BAuU). Crucially, existing energy policies are not a sunk effort; as impacts of existing policy initiatives are targeted at future years, they may be revised through iterative policy making, and their quantitative effectiveness requires ex-post verification. To assess the long-term role of existing policies in energy modelling, currently identified UK policies are explicitly stripped out of the UK MARKAL Elastic Demand (MED) optimisation energy system model, to generate a BAuU (with-policy) and a REF (without policy) baseline. In terms of long-term mitigation costs, policy-baseline assumptions are comparable to another key exogenous modelling assumption - that of global fossil fuel prices. Therefore, best practice in energy modelling would be to have both a no-policy reference baseline, and a current policy reference baseline (BAuU). At a minimum, energy modelling studies should have a transparent assessment of the current policy contained within the baseline. Clearly identifying and comparing policy-baseline assumptions are required for cost effective and objective policy making, otherwise energy models will underestimate the true cost of long-term emissions reductions.

  10. Pakistan, Sindh Province - Baseline Indicators System : Baseline Procurement Performance Assessment Report

    OpenAIRE

    World Bank

    2009-01-01

    This document provides an assessment of the public procurement system in Sindh province using the baseline indicators system developed by the Development Assistance Committee of the Organization for Economic Cooperation and Development (OECD-DAC). This assessment, interviews and discussions were held with stakeholders from the public and private sectors as well as civil society. Developing...

  11. Commercial Building Energy Baseline Modeling Software: Performance Metrics and Method Testing with Open Source Models and Implications for Proprietary Software Testing

    Energy Technology Data Exchange (ETDEWEB)

    Price, Phillip N.; Granderson, Jessica; Sohn, Michael; Addy, Nathan; Jump, David

    2013-09-01

    The overarching goal of this work is to advance the capabilities of technology evaluators in evaluating the building-level baseline modeling capabilities of Energy Management and Information System (EMIS) software. Through their customer engagement platforms and products, EMIS software products have the potential to produce whole-building energy savings through multiple strategies: building system operation improvements, equipment efficiency upgrades and replacements, and inducement of behavioral change among the occupants and operations personnel. Some offerings may also automate the quantification of whole-building energy savings, relative to a baseline period, using empirical models that relate energy consumption to key influencing parameters, such as ambient weather conditions and building operation schedule. These automated baseline models can be used to streamline the whole-building measurement and verification (M&V) process, and therefore are of critical importance in the context of multi-measure whole-building focused utility efficiency programs. This report documents the findings of a study that was conducted to begin answering critical questions regarding quantification of savings at the whole-building level, and the use of automated and commercial software tools. To evaluate the modeling capabilities of EMIS software particular to the use case of whole-building savings estimation, four research questions were addressed: 1. What is a general methodology that can be used to evaluate baseline model performance, both in terms of a) overall robustness, and b) relative to other models? 2. How can that general methodology be applied to evaluate proprietary models that are embedded in commercial EMIS tools? How might one handle practical issues associated with data security, intellectual property, appropriate testing ‘blinds’, and large data sets? 3. How can buildings be pre-screened to identify those that are the most model-predictable, and therefore those

  12. Life Support Baseline Values and Assumptions Document

    Science.gov (United States)

    Anderson, Molly S.; Ewert, Michael K.; Keener, John F.

    2018-01-01

    The Baseline Values and Assumptions Document (BVAD) provides analysts, modelers, and other life support researchers with a common set of values and assumptions which can be used as a baseline in their studies. This baseline, in turn, provides a common point of origin from which many studies in the community may depart, making research results easier to compare and providing researchers with reasonable values to assume for areas outside their experience. This document identifies many specific physical quantities that define life support systems, serving as a general reference for spacecraft life support system technology developers.

  13. Utilities and offsites design baseline. Outside Battery Limits Facility 6000 tpd SRC-I Demonstration Plant. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    None

    1984-05-25

    As part of the overall Solvent Refined Coal (SRC-1) project baseline being prepared by International Coal Refining Company (ICRC), the RUST Engineering Company is providing necessary input for the Outside Battery Limits (OSBL) Facilities. The project baseline is comprised of: design baseline - technical definition of work; schedule baseline - detailed and management level 1 schedules; and cost baseline - estimates and cost/manpower plan. The design baseline (technical definition) for the OSBL Facilities has been completed and is presented in Volumes I, II, III, IV, V and VI. The OSBL technical definition is based on, and compatible with, the ICRC defined statement of work, design basis memorandum, master project procedures, process and mechanical design criteria, and baseline guidance documents. The design basis memorandum is included in Paragraph 1.3 of Volume I. The baseline design data is presented in 6 volumes. Volume I contains the introduction section and utility systems data through steam and feedwater. Volume II continues with utility systems data through fuel system, and contains the interconnecting systems and utility system integration information. Volume III contains the offsites data through water and waste treatment. Volume IV continues with offsites data, including site development and buildings, and contains raw materials and product handling and storage information. Volume V contains wastewater treatment and solid wastes landfill systems developed by Catalytic, Inc. to supplement the information contained in Volume III. Volume VI contains proprietary information of Resources Conservation Company related to the evaporator/crystallizer system of the wastewater treatment area.

  14. FAQs about Baseline Testing among Young Athletes

    Science.gov (United States)

    ... a similar exam conducted by a health care professional during the season if an athlete has a suspected concussion. Baseline testing generally takes place during the pre-season—ideally prior to the first practice. It is important to note that some baseline ...

  15. 75 FR 74706 - Notice of Baseline Filings

    Science.gov (United States)

    2010-12-01

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Notice of Baseline Filings November 24, 2010. Centana Intrastate Pipeline, LLC. Docket No. PR10-84-001. Centana Intrastate Pipeline, LLC... applicants listed above submitted a revised baseline filing of their Statement of Operating Conditions for...

  16. High-Level software requirements specification for the TWRS controlled baseline database system

    International Nuclear Information System (INIS)

    Spencer, S.G.

    1998-01-01

    This Software Requirements Specification (SRS) is an as-built document that presents the Tank Waste Remediation System (TWRS) Controlled Baseline Database (TCBD) in its current state. It was originally known as the Performance Measurement Control System (PMCS). Conversion to the new system name has not occurred within the current production system. Therefore, for simplicity, all references to TCBD are equivalent to PMCS references. This SRS will reference the PMCS designator from this point forward to capture the as-built SRS. This SRS is written at a high-level and is intended to provide the design basis for the PMCS. The PMCS was first released as the electronic data repository for cost, schedule, and technical administrative baseline information for the TAAS Program. During its initial development, the PMCS was accepted by the customer, TARS Business Management, with no formal documentation to capture the initial requirements

  17. Unintended cultivation, shifting baselines, and conflict between objectives for fisheries and conservation.

    Science.gov (United States)

    Brown, Christopher J; Trebilco, Rowan

    2014-06-01

    The effects of fisheries on marine ecosystems, and their capacity to drive shifts in ecosystem states, have been widely documented. Less well appreciated is that some commercially valuable species respond positively to fishing-induced ecosystem change and can become important fisheries resources in modified ecosystems. Thus, the ecological effects of one fishery can unintentionally increase the abundance and productivity of other fished species (i.e., cultivate). We reviewed examples of this effect in the peer-reviewed literature. We found 2 underlying ecosystem drivers of the effect: trophic release of prey species when predators are overfished and habitat change. Key ecological, social, and economic conditions required for one fishery to unintentionally cultivate another include strong top-down control of prey by predators, the value of the new fishery, and the capacity of fishers to adapt to a new fishery. These unintended cultivation effects imply strong trade-offs between short-term fishery success and conservation efforts to restore ecosystems toward baseline conditions because goals for fisheries and conservation may be incompatible. Conflicts are likely to be exacerbated if fisheries baselines shift relative to conservation baselines and there is investment in the new fishery. However, in the long-term, restoration toward ecosystem baselines may often benefit both fishery and conservation goals. Unintended cultivation can be identified and predicted using a combination of time-series data, dietary studies, models of food webs, and socioeconomic data. Identifying unintended cultivation is necessary for management to set compatible goals for fisheries and conservation. © 2014 Society for Conservation Biology.

  18. Scheme for Generation highly monochromatic X-Rays from a baseline XFEL undulator

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2010-03-01

    One goal of XFEL facilities is the production of narrow bandwidth X-ray radiation. The self-seeding scheme was proposed to obtain a bandwidth narrower than that achievable with conventional X-ray SASE FELs. A self-seeded FEL is composed of two undulators separated by a monochromator and an electron beam bypass that must compensate for the path delay of X-rays in the monochromator. This leads to a long bypass, with a length in the order of 40-60 m, which requires modifications of the baseline undulator configuration. As an attempt to get around this obstacle, together with a study of the self-seeding scheme for the European XFEL, here we propose a novel technique based on a pulse doubler concept. Using a crystal monochromator installed within a short magnetic chicane in the baseline undulator, it is possible to decrease the bandwidth of the radiation well beyond the XFEL design down to 10 -5 . The magnetic chicane can be installed without any perturbation of the XFEL focusing structure, and does not interfere with the baseline mode of operation. We present a feasibility study and we make exemplifications with the parameters of the SASE2 line of the European XFEL. (orig.)

  19. 40 CFR 82.20 - Availability of consumption allowances in addition to baseline consumption allowances for class...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Availability of consumption allowances in addition to baseline consumption allowances for class II controlled substances. 82.20 Section 82...) PROTECTION OF STRATOSPHERIC OZONE Production and Consumption Controls § 82.20 Availability of consumption...

  20. Geochemical baseline studies of soil in Finland

    Science.gov (United States)

    Pihlaja, Jouni

    2017-04-01

    The soil element concentrations regionally vary a lot in Finland. Mostly this is caused by the different bedrock types, which are reflected in the soil qualities. Geological Survey of Finland (GTK) is carrying out geochemical baseline studies in Finland. In the previous phase, the research is focusing on urban areas and mine environments. The information can, for example, be used to determine the need for soil remediation, to assess environmental impacts or to measure the natural state of soil in industrial areas or mine districts. The field work is done by taking soil samples, typically at depth between 0-10 cm. Sampling sites are chosen to represent the most vulnerable areas when thinking of human impacts by possible toxic soil element contents: playgrounds, day-care centers, schools, parks and residential areas. In the mine districts the samples are taken from the areas locating outside the airborne dust effected areas. Element contents of the soil samples are then analyzed with ICP-AES and ICP-MS, Hg with CV-AAS. The results of the geochemical baseline studies are published in the Finnish national geochemical baseline database (TAPIR). The geochemical baseline map service is free for all users via internet browser. Through this map service it is possible to calculate regional soil baseline values using geochemical data stored in the map service database. Baseline data for 17 elements in total is provided in the map service and it can be viewed on the GTK's web pages (http://gtkdata.gtk.fi/Tapir/indexEN.html).

  1. Baseline evaluation of hand hygiene compliance in three major hospitals, Isfahan, Iran.

    Science.gov (United States)

    Ataei, B; Zahraei, S M; Pezeshki, Z; Babak, A; Nokhodian, Z; Mobasherizadeh, S; Hoseini, S G

    2013-09-01

    Hand hygiene is the mainstay of nosocomial infection prevention. This study was a baseline survey to assess hand hygiene compliance of healthcare workers by direct observation in three major hospitals of Isfahan, Iran. The use of different hand hygiene products was also evaluated. In 3078 potential opportunities hand hygiene products were available on 2653 occasions (86.2%). Overall compliance was 6.4% (teaching hospital: 7.4%; public hospital: 6.2%; private hospital: 1.4%). Nurses (8.4%) had the highest rates of compliance. Poor hand hygiene compliance in Isfahan hospitals necessitates urgent interventions to improve both hospital infrastructure and staff knowledge. © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. Intrafractional baseline drift during free breathing breast cancer radiation therapy.

    Science.gov (United States)

    Jensen, Christer Andre; Acosta Roa, Ana María; Lund, Jo-Åsmund; Frengen, Jomar

    2017-06-01

    Intrafraction motion in breast cancer radiation therapy (BCRT) has not yet been thoroughly described in the literature. It has been observed that baseline drift occurs as part of the intrafraction motion. This study aims to measure baseline drift and its incidence in free-breathing BCRT patients using an in-house developed laser system for tracking the position of the sternum. Baseline drift was monitored in 20 right-sided breast cancer patients receiving free breathing 3D-conformal RT by using an in-house developed laser system which measures one-dimensional distance in the AP direction. A total of 357 patient respiratory traces from treatment sessions were logged and analysed. Baseline drift was compared to patient positioning error measured from in-field portal imaging. The mean overall baseline drift at end of treatment sessions was -1.3 mm for the patient population. Relatively small baseline drift was observed during the first fraction; however it was clearly detected already at the second fraction. Over 90% of the baseline drift occurs during the first 3 min of each treatment session. The baseline drift rate for the population was -0.5 ± 0.2 mm/min in the posterior direction the first minute after localization. Only 4% of the treatment sessions had a 5 mm or larger baseline drift at 5 min, all towards the posterior direction. Mean baseline drift in the posterior direction in free breathing BCRT was observed in 18 of 20 patients over all treatment sessions. This study shows that there is a substantial baseline drift in free breathing BCRT patients. No clear baseline drift was observed during the first treatment session; however, baseline drift was markedly present at the rest of the sessions. Intrafraction motion due to baseline drift should be accounted for in margin calculations.

  3. Carbon gas fluxes in re-established wetlands on organic soils differ relative to plant community and hydrology

    Science.gov (United States)

    Miller, Robin L.

    2011-01-01

    We measured CO2 and CH4 fluxes for 6 years following permanent flooding of an agriculturally managed organic soil at two water depths (~25 and ~55 cm standing water) in the Sacramento–San Joaquin Delta, California, as part of research studying C dynamics in re-established wetlands. Flooding rapidly reduced gaseous C losses, and radiocarbon data showed that this, in part, was due to reduced oxidation of "old" C preserved in the organic soils. Both CO2 and CH4 emissions from the water surface increased during the first few growing seasons, concomitant with emergent marsh establishment, and thereafter appeared to stabilize according to plant communities. Areas of emergent marsh vegetation in the shallower wetland had greater net CO2 influx (-485 mg Cm-1 h-1), and lower CH4 emissions (11.5 mg Cm-2 h-1), than in the deeper wetland (-381 and 14.1 mg Cm-2 h-1, respectively). Areas with submerged and floating vegetation in the deeper wetland had CH4 emissions similar to emergent vegetation (11.9 and 12.6 mg Cm-2 h-1, respectively), despite lower net CO2 influx (-102 gC m-2 h-1). Measurements of plant moderated net CO2 influx and CH4 efflux indicated greatest potential reduction of greenhouse gases in the more shallowly flooded wetland.

  4. Extracting Baseline Electricity Usage Using Gradient Tree Boosting

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Taehoon [Ulsan Nat. Inst. of Sci. & Tech., Ulsan (South Korea); Lee, Dongeun [Ulsan Nat. Inst. of Sci. & Tech., Ulsan (South Korea); Choi, Jaesik [Ulsan Nat. Inst. of Sci. & Tech., Ulsan (South Korea); Spurlock, Anna [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sim, Alex [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Todd, Annika [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wu, Kesheng [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-05-05

    To understand how specific interventions affect a process observed over time, we need to control for the other factors that influence outcomes. Such a model that captures all factors other than the one of interest is generally known as a baseline. In our study of how different pricing schemes affect residential electricity consumption, the baseline would need to capture the impact of outdoor temperature along with many other factors. In this work, we examine a number of different data mining techniques and demonstrate Gradient Tree Boosting (GTB) to be an effective method to build the baseline. We train GTB on data prior to the introduction of new pricing schemes, and apply the known temperature following the introduction of new pricing schemes to predict electricity usage with the expected temperature correction. Our experiments and analyses show that the baseline models generated by GTB capture the core characteristics over the two years with the new pricing schemes. In contrast to the majority of regression based techniques which fail to capture the lag between the peak of daily temperature and the peak of electricity usage, the GTB generated baselines are able to correctly capture the delay between the temperature peak and the electricity peak. Furthermore, subtracting this temperature-adjusted baseline from the observed electricity usage, we find that the resulting values are more amenable to interpretation, which demonstrates that the temperature-adjusted baseline is indeed effective.

  5. 75 FR 57268 - Notice of Baseline Filings

    Science.gov (United States)

    2010-09-20

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-103-000; Docket No. PR10-104-000; Docket No. PR10-105- 000 (Not Consolidated)] Notice of Baseline Filings September 13..., 2010, and September 10, 2010, respectively the applicants listed above submitted their baseline filing...

  6. Rapidly shifting environmental baselines among fishers of the Gulf of California

    Science.gov (United States)

    Sáenz-Arroyo, Andrea; Roberts, Callum M; Torre, Jorge; Cariño-Olvera, Micheline; Enríquez-Andrade, Roberto R

    2005-01-01

    Shifting environmental baselines are inter-generational changes in perception of the state of the environment. As one generation replaces another, people's perceptions of what is natural change even to the extent that they no longer believe historical anecdotes of past abundance or size of species. Although widely accepted, this phenomenon has yet to be quantitatively tested. Here we survey three generations of fishers from Mexico's Gulf of California (N=108), where fish populations have declined steeply over the last 60 years, to investigate how far and fast their environmental baselines are shifting. Compared to young fishers, old fishers named five times as many species and four times as many fishing sites as once being abundant/productive but now depleted (Kruskal–Wallis tests, both p<0.001) with no evidence of a slowdown in rates of loss experienced by younger compared to older generations (Kruskal–Wallis test, n.s. in both cases). Old fishers caught up to 25 times as many Gulf grouper Mycteroperca jordani as young fishers on their best ever fishing day (regression r2=0.62, p<0.001). Despite times of plentiful large fish still being within living memory, few young fishers appreciated that large species had ever been common or nearshore sites productive. Such rapid shifts in perception of what is natural help explain why society is tolerant of the creeping loss of biodiversity. They imply a large educational hurdle in efforts to reset expectations and targets for conservation. PMID:16191603

  7. 75 FR 65010 - Notice of Baseline Filings

    Science.gov (United States)

    2010-10-21

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR11-1-000; Docket No. PR11-2-000; Docket No. PR11-3-000] Notice of Baseline Filings October 14, 2010. Cranberry Pipeline Docket..., 2010, respectively the applicants listed above submitted their baseline filing of its Statement of...

  8. THE 2014 ALMA LONG BASELINE CAMPAIGN: AN OVERVIEW

    Energy Technology Data Exchange (ETDEWEB)

    Partnership, ALMA [Astrophysics Research Institute, Liverpool John Moores University, IC2, Liverpool Science Park, 146 Brownlow Hill, Liverpool L3 5RF (United Kingdom); Fomalont, E. B.; Vlahakis, C.; Corder, S.; Remijan, A.; Barkats, D.; Dent, W. R. F.; Phillips, N.; Cox, P.; Hales, A. S. [Joint ALMA Observatory, Alonso de Córdova 3107, Vitacura, Santiago (Chile); Lucas, R. [Institut de Planétologie et d’Astrophysique de Grenoble (UMR 5274), BP 53, F-38041 Grenoble Cedex 9 (France); Hunter, T. R.; Brogan, C. L.; Amestica, R.; Cotton, W. [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22903 (United States); Asaki, Y. [National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan); Matsushita, S. [Institute of Astronomy and Astrophysics, Academia Sinica, P.O. Box 23-141, Taipei 106, Taiwan (China); Hills, R. E. [Astrophysics Group, Cavendish Laboratory, JJ Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Richards, A. M. S. [Jodrell Bank Centre for Astrophysics, School of Physics and Astronomy, University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom); Broguiere, D., E-mail: efomalon@nrao.edu [Institut de Radioastronomie Millime´trique (IRAM), 300 rue de la Piscine, Domaine Universitaire, F-38406 Saint Martin d’Hères (France); and others

    2015-07-20

    A major goal of the Atacama Large Millimeter/submillimeter Array (ALMA) is to make accurate images with resolutions of tens of milliarcseconds, which at submillimeter (submm) wavelengths requires baselines up to ∼15 km. To develop and test this capability, a Long Baseline Campaign (LBC) was carried out from 2014 September to late November, culminating in end-to-end observations, calibrations, and imaging of selected Science Verification (SV) targets. This paper presents an overview of the campaign and its main results, including an investigation of the short-term coherence properties and systematic phase errors over the long baselines at the ALMA site, a summary of the SV targets and observations, and recommendations for science observing strategies at long baselines. Deep ALMA images of the quasar 3C 138 at 97 and 241 GHz are also compared to VLA 43 GHz results, demonstrating an agreement at a level of a few percent. As a result of the extensive program of LBC testing, the highly successful SV imaging at long baselines achieved angular resolutions as fine as 19 mas at ∼350 GHz. Observing with ALMA on baselines of up to 15 km is now possible, and opens up new parameter space for submm astronomy.

  9. THE 2014 ALMA LONG BASELINE CAMPAIGN: AN OVERVIEW

    International Nuclear Information System (INIS)

    Partnership, ALMA; Fomalont, E. B.; Vlahakis, C.; Corder, S.; Remijan, A.; Barkats, D.; Dent, W. R. F.; Phillips, N.; Cox, P.; Hales, A. S.; Lucas, R.; Hunter, T. R.; Brogan, C. L.; Amestica, R.; Cotton, W.; Asaki, Y.; Matsushita, S.; Hills, R. E.; Richards, A. M. S.; Broguiere, D.

    2015-01-01

    A major goal of the Atacama Large Millimeter/submillimeter Array (ALMA) is to make accurate images with resolutions of tens of milliarcseconds, which at submillimeter (submm) wavelengths requires baselines up to ∼15 km. To develop and test this capability, a Long Baseline Campaign (LBC) was carried out from 2014 September to late November, culminating in end-to-end observations, calibrations, and imaging of selected Science Verification (SV) targets. This paper presents an overview of the campaign and its main results, including an investigation of the short-term coherence properties and systematic phase errors over the long baselines at the ALMA site, a summary of the SV targets and observations, and recommendations for science observing strategies at long baselines. Deep ALMA images of the quasar 3C 138 at 97 and 241 GHz are also compared to VLA 43 GHz results, demonstrating an agreement at a level of a few percent. As a result of the extensive program of LBC testing, the highly successful SV imaging at long baselines achieved angular resolutions as fine as 19 mas at ∼350 GHz. Observing with ALMA on baselines of up to 15 km is now possible, and opens up new parameter space for submm astronomy

  10. Effect of Soil Filtration and Ozonation in the Change of Baseline Toxicity in Wastewater Spiked with Organic Micro-pollutants

    KAUST Repository

    Gan, Alexander

    2012-01-01

    Bioassays for baseline toxicity, which measure toxicants’ non-specific effects, have been shown in previous studies to effectively correlate with the increased presence of pharmaceuticals, personal care products, endocrine-disrupting compounds

  11. 76 FR 8725 - Notice of Baseline Filings

    Science.gov (United States)

    2011-02-15

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Notice of Baseline Filings Enstor Grama Ridge Storage and Docket No. PR10-97-002. Transportation, L.L.C.. EasTrans, LLC Docket No. PR10-30-001... revised baseline filing of their Statement of Operating Conditions for services provided under section 311...

  12. 76 FR 5797 - Notice of Baseline Filings

    Science.gov (United States)

    2011-02-02

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-114-001; Docket No. PR10-129-001; Docket No. PR10-131- 001; Docket No. PR10-68-002 Not Consolidated] Notice of Baseline... applicants listed above submitted a revised baseline filing of their Statement of Operating Conditions for...

  13. Office of Geologic Repositories program baseline procedures notebook (OGR/B-1)

    International Nuclear Information System (INIS)

    1986-06-01

    Baseline management is typically applied to aid in the internal control of a program by providing consistent programmatic direction, control, and surveillance to an evolving system development. This fundamental concept of internal program control involves the establishment of a baseline to serve as a point of departure for consistent technical program coordination and to control subsequent changes from that baseline. The existence of a program-authorized baseline ensures that all participants are working to the same ground rules. Baseline management also ensures that, once the baseline is defined, changes are assessed and approved by a process which ensures adequate consideration of overall program impact. Baseline management also includes the consideration of examptions from the baseline. The process of baseline management continues through all the phases of an evolving system development program. As the Program proceeds, there will be a progressive increase in the data contained in the baseline documentation. Baseline management has been selected as a management technique to aid in the internal control of the Office of Geologic Repositories (OGR) program. Specifically, an OGR Program Baseline, including technical and programmatic requirements, is used for program control of the four Mined Geologic Disposal System field projects, i.e., Basalt Waste Isolation Project, Nevada Nuclear Waste Storage Investigation, Salt Repository Project and Crystalline Repository Project. This OGR Program Baseline Procedures Notebook provides a description of the baseline mwanagement concept, establishes the OGR Program baseline itself, and provides procedures to be followed for controlling changes to that baseline. The notebook has a controlled distribution and will be updated as required

  14. Accelerated Best Basis Inventory Baselining Task

    International Nuclear Information System (INIS)

    SASAKI, L.M.

    2001-01-01

    The baselining effort was recently proposed to bring the Best-Basis Inventory (BBI) and Question No.8 of the Tank Interpretive Report (TIR) for all 177 tanks to the current standards and protocols and to prepare a TIR Question No.8 if one is not already available. This plan outlines the objectives and methodology of the accelerated BBI baselining task. BBI baselining meetings held during December 2000 resulted in a revised BBI methodology and an initial set of BBI creation rules to be used in the baselining effort. The objectives of the BBI baselining effort are to: (1) Provide inventories that are consistent with the revised BBI methodology and new BBI creation rules. (2) Split the total tank waste in each tank into six waste phases, as appropriate (Supernatant, saltcake solids, saltcake liquid, sludge solids, sludge liquid, and retained gas). In some tanks, the solids and liquid portions of the sludge and/or saltcake may be combined into a single sludge or saltcake phase. (3) Identify sampling events that are to be used for calculating the BBIs. (4) Update waste volumes for subsequent reconciliation with the Hanlon (2001) waste tank summary. (5) Implement new waste type templates. (6) Include any sample data that might have been unintentionally omitted in the previous BBI and remove any sample data that should not have been included. Sample data to be used in the BBI must be available on TWINS. (7) Ensure that an inventory value for each standard BBI analyte is provided for each waste component. Sample based inventories for supplemental BBI analytes will be included when available. (8) Provide new means and confidence interval reports if one is not already available and include uncertainties in reporting inventory values

  15. 75 FR 70732 - Notice of Baseline Filings

    Science.gov (United States)

    2010-11-18

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR11-71-000; Docket No. PR11-72-000; Docket No. PR11-73- 000] Notice of Baseline Filings November 10, 2010. Docket No. PR11-71-000..., 2010, the applicants listed above submitted their baseline filing of their Statement of Operating...

  16. MALDI-TOF Baseline Drift Removal Using Stochastic Bernstein Approximation

    Directory of Open Access Journals (Sweden)

    Howard Daniel

    2006-01-01

    Full Text Available Stochastic Bernstein (SB approximation can tackle the problem of baseline drift correction of instrumentation data. This is demonstrated for spectral data: matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF data. Two SB schemes for removing the baseline drift are presented: iterative and direct. Following an explanation of the origin of the MALDI-TOF baseline drift that sheds light on the inherent difficulty of its removal by chemical means, SB baseline drift removal is illustrated for both proteomics and genomics MALDI-TOF data sets. SB is an elegant signal processing method to obtain a numerically straightforward baseline shift removal method as it includes a free parameter that can be optimized for different baseline drift removal applications. Therefore, research that determines putative biomarkers from the spectral data might benefit from a sensitivity analysis to the underlying spectral measurement that is made possible by varying the SB free parameter. This can be manually tuned (for constant or tuned with evolutionary computation (for .

  17. Physics Potential of Long-Baseline Experiments

    Directory of Open Access Journals (Sweden)

    Sanjib Kumar Agarwalla

    2014-01-01

    Full Text Available The discovery of neutrino mixing and oscillations over the past decade provides firm evidence for new physics beyond the Standard Model. Recently, θ13 has been determined to be moderately large, quite close to its previous upper bound. This represents a significant milestone in establishing the three-flavor oscillation picture of neutrinos. It has opened up exciting prospects for current and future long-baseline neutrino oscillation experiments towards addressing the remaining fundamental questions, in particular the type of the neutrino mass hierarchy and the possible presence of a CP-violating phase. Another recent and crucial development is the indication of non-maximal 2-3 mixing angle, causing the octant ambiguity of θ23. In this paper, I will review the phenomenology of long-baseline neutrino oscillations with a special emphasis on sub-leading three-flavor effects, which will play a crucial role in resolving these unknowns. First, I will give a brief description of neutrino oscillation phenomenon. Then, I will discuss our present global understanding of the neutrino mass-mixing parameters and will identify the major unknowns in this sector. After that, I will present the physics reach of current generation long-baseline experiments. Finally, I will conclude with a discussion on the physics capabilities of accelerator-driven possible future long-baseline precision oscillation facilities.

  18. Precise baseline determination for the TanDEM-X mission

    Science.gov (United States)

    Koenig, Rolf; Moon, Yongjin; Neumayer, Hans; Wermuth, Martin; Montenbruck, Oliver; Jäggi, Adrian

    The TanDEM-X mission will strive for generating a global precise Digital Elevation Model (DEM) by way of bi-static SAR in a close formation of the TerraSAR-X satellite, already launched on June 15, 2007, and the TanDEM-X satellite to be launched in May 2010. Both satellites carry the Tracking, Occultation and Ranging (TOR) payload supplied by the GFZ German Research Centre for Geosciences. The TOR consists of a high-precision dual-frequency GPS receiver, called Integrated GPS Occultation Receiver (IGOR), and a Laser retro-reflector (LRR) for precise orbit determination (POD) and atmospheric sounding. The IGOR is of vital importance for the TanDEM-X mission objectives as the millimeter level determination of the baseline or distance between the two spacecrafts is needed to derive meter level accurate DEMs. Within the TanDEM-X ground segment GFZ is responsible for the operational provision of precise baselines. For this GFZ uses two software chains, first its Earth Parameter and Orbit System (EPOS) software and second the BERNESE software, for backup purposes and quality control. In a concerted effort also the German Aerospace Center (DLR) generates precise baselines independently with a dedicated Kalman filter approach realized in its FRNS software. By the example of GRACE the generation of baselines with millimeter accuracy from on-board GPS data can be validated directly by way of comparing them to the intersatellite K-band range measurements. The K-band ranges are accurate down to the micrometer-level and therefore may be considered as truth. Both TanDEM-X baseline providers are able to generate GRACE baselines with sub-millimeter accuracy. By merging the independent baselines by GFZ and DLR, the accuracy can even be increased. The K-band validation however covers solely the along-track component as the K-band data measure just the distance between the two GRACE satellites. In addition they inhibit an un-known bias which must be modelled in the comparison, so the

  19. Summary of Plutonium-238 Production Alternatives Analysis Final Report

    Energy Technology Data Exchange (ETDEWEB)

    James Werner; Wade E. Bickford; David B. Lord; Chadwick D. Barklay

    2013-03-01

    The Team implemented a two-phase evaluation process. During the first phase, a wide variety of past and new candidate facilities and processing methods were assessed against the criteria established by DOE for this assessment. Any system or system element selected for consideration as an alternative within the project to reestablish domestic production of Pu-238 must meet the following minimum criteria: Any required source material must be readily available in the United States, without requiring the development of reprocessing technologies or investments in systems to separate material from identified sources. It must be cost, schedule, and risk competitive with existing baseline technology. Any identified facilities required to support the concept must be available to the program for the entire project life cycle (notionally 35 years, unless the concept is so novel as to require a shorter duration). It must present a solution that can generate at least 1.5 Kg of Pu-238 oxide per year, for at least 35 years. It must present a low-risk, near-term solution to the National Aeronautics and Space Administration’s urgent mission need. DOE has implemented this requirement by eliminating from project consideration any alternative with key technologies at less than Technology Readiness Level 5. The Team evaluated the options meeting these criteria using a more detailed assessment of the reasonable facility variations and compared them to the preferred option, which consists of target irradiation at the Advanced Test Reactor (ATR) and the High Flux Isotope Reactor (HFIR), target fabrication and chemical separations processing at the ORNL Radiochemical Engineering Development Center, and neptunium 237 storage at the Materials and Fuels Complex at INL. This preferred option is consistent with the Records of Decision from the earlier National Environmental Policy Act (NEPA) documentation

  20. Baseline Response Levels Are a Nuisance in Infant Contingency Learning

    Science.gov (United States)

    Millar, W. S.; Weir, Catherine

    2015-01-01

    The impact of differences in level of baseline responding on contingency learning in the first year was examined by considering the response acquisition of infants classified into baseline response quartiles. Whereas the three lower baseline groups showed the predicted increment in responding to a contingency, the highest baseline responders did…

  1. IPCC Socio-Economic Baseline Dataset

    Data.gov (United States)

    National Aeronautics and Space Administration — The Intergovernmental Panel on Climate Change (IPCC) Socio-Economic Baseline Dataset consists of population, human development, economic, water resources, land...

  2. Baseline methodologies for clean development mechanism projects

    Energy Technology Data Exchange (ETDEWEB)

    Lee, M.K. (ed.); Shrestha, R.M.; Sharma, S.; Timilsina, G.R.; Kumar, S.

    2005-11-15

    The Kyoto Protocol and the Clean Development Mechanism (CDM) came into force on 16th February 2005 with its ratification by Russia. The increasing momentum of this process is reflected in more than 100 projects having been submitted to the CDM Executive Board (CDM-EB) for approval of the baselines and monitoring methodologies, which is the first step in developing and implementing CDM projects. A CDM project should result in a net decrease of GHG emissions below any level that would have resulted from other activities implemented in the absence of that CDM project. The 'baseline' defines the GHG emissions of activities that would have been implemented in the absence of a CDM project. The baseline methodology is the process/algorithm for establishing that baseline. The baseline, along with the baseline methodology, are thus the most critical element of any CDM project towards meeting the important criteria of CDM, which are that a CDM should result in 'real, measurable, and long term benefits related to the mitigation of climate change'. This guidebook is produced within the frame work of the United Nations Environment Programme (UNEP) facilitated 'Capacity Development for the Clean Development Mechanism (CD4CDM)' Project. This document is published as part of the projects effort to develop guidebooks that cover important issues such as project finance, sustainability impacts, legal framework and institutional framework. These materials are aimed to help stakeholders better understand the CDM and are believed to eventually contribute to maximize the effect of the CDM in achieving the ultimate goal of UNFCCC and its Kyoto Protocol. This Guidebook should be read in conjunction with the information provided in the two other guidebooks entitled, 'Clean Development Mechanism: Introduction to the CDM' and 'CDM Information and Guidebook' developed under the CD4CDM project. (BA)

  3. Baseline methodologies for clean development mechanism projects

    International Nuclear Information System (INIS)

    Lee, M.K.; Shrestha, R.M.; Sharma, S.; Timilsina, G.R.; Kumar, S.

    2005-11-01

    The Kyoto Protocol and the Clean Development Mechanism (CDM) came into force on 16th February 2005 with its ratification by Russia. The increasing momentum of this process is reflected in more than 100 projects having been submitted to the CDM Executive Board (CDM-EB) for approval of the baselines and monitoring methodologies, which is the first step in developing and implementing CDM projects. A CDM project should result in a net decrease of GHG emissions below any level that would have resulted from other activities implemented in the absence of that CDM project. The 'baseline' defines the GHG emissions of activities that would have been implemented in the absence of a CDM project. The baseline methodology is the process/algorithm for establishing that baseline. The baseline, along with the baseline methodology, are thus the most critical element of any CDM project towards meeting the important criteria of CDM, which are that a CDM should result in 'real, measurable, and long term benefits related to the mitigation of climate change'. This guidebook is produced within the frame work of the United Nations Environment Programme (UNEP) facilitated 'Capacity Development for the Clean Development Mechanism (CD4CDM)' Project. This document is published as part of the projects effort to develop guidebooks that cover important issues such as project finance, sustainability impacts, legal framework and institutional framework. These materials are aimed to help stakeholders better understand the CDM and are believed to eventually contribute to maximize the effect of the CDM in achieving the ultimate goal of UNFCCC and its Kyoto Protocol. This Guidebook should be read in conjunction with the information provided in the two other guidebooks entitled, 'Clean Development Mechanism: Introduction to the CDM' and 'CDM Information and Guidebook' developed under the CD4CDM project. (BA)

  4. Baseline budgeting for continuous improvement.

    Science.gov (United States)

    Kilty, G L

    1999-05-01

    This article is designed to introduce the techniques used to convert traditionally maintained department budgets to baseline budgets. This entails identifying key activities, evaluating for value-added, and implementing continuous improvement opportunities. Baseline Budgeting for Continuous Improvement was created as a result of a newly named company president's request to implement zero-based budgeting. The president was frustrated with the mind-set of the organization, namely, "Next year's budget should be 10 to 15 percent more than this year's spending." Zero-based budgeting was not the answer, but combining the principles of activity-based costing and the Just-in-Time philosophy of eliminating waste and continuous improvement did provide a solution to the problem.

  5. Safe and sensible preprocessing and baseline correction of pupil-size data.

    Science.gov (United States)

    Mathôt, Sebastiaan; Fabius, Jasper; Van Heusden, Elle; Van der Stigchel, Stefan

    2018-02-01

    Measurement of pupil size (pupillometry) has recently gained renewed interest from psychologists, but there is little agreement on how pupil-size data is best analyzed. Here we focus on one aspect of pupillometric analyses: baseline correction, i.e., analyzing changes in pupil size relative to a baseline period. Baseline correction is useful in experiments that investigate the effect of some experimental manipulation on pupil size. In such experiments, baseline correction improves statistical power by taking into account random fluctuations in pupil size over time. However, we show that baseline correction can also distort data if unrealistically small pupil sizes are recorded during the baseline period, which can easily occur due to eye blinks, data loss, or other distortions. Divisive baseline correction (corrected pupil size = pupil size/baseline) is affected more strongly by such distortions than subtractive baseline correction (corrected pupil size = pupil size - baseline). We discuss the role of baseline correction as a part of preprocessing of pupillometric data, and make five recommendations: (1) before baseline correction, perform data preprocessing to mark missing and invalid data, but assume that some distortions will remain in the data; (2) use subtractive baseline correction; (3) visually compare your corrected and uncorrected data; (4) be wary of pupil-size effects that emerge faster than the latency of the pupillary response allows (within ±220 ms after the manipulation that induces the effect); and (5) remove trials on which baseline pupil size is unrealistically small (indicative of blinks and other distortions).

  6. Performance Measurement Baseline Change Request

    Data.gov (United States)

    Social Security Administration — The Performance Measurement Baseline Change Request template is used to document changes to scope, cost, schedule, or operational performance metrics for SSA's Major...

  7. Wind power projects in the CDM: Methodologies and tools for baselines, carbon financing and sustainability analysis

    International Nuclear Information System (INIS)

    Ringius, L.; Grohnheit, P.E.; Nielsen, L.H.; Olivier, A.L.; Painuly, J.; Villavicencio, A.

    2002-12-01

    The report is intended to be a guidance document for project developers, investors, lenders, and CDM host countries involved in wind power projects in the CDM. The report explores in particular those issues that are important in CDM project assessment and development - that is, baseline development, carbon financing, and environmental sustainability. It does not deal in detail with those issues that are routinely covered in a standard wind power project assessment. The report tests, compares, and recommends methodologies for and approaches to baseline development. To present the application and implications of the various methodologies and approaches in a concrete context, Africa's largest wind farm-namely the 60 MW wind farm located in Zafarana, Egypt- is examined as a hypothetical CDM wind power project The report shows that for the present case example there is a difference of about 25% between the lowest (0.5496 tCO2/MWh) and the highest emission rate (0.6868 tCO 2 /MWh) estimated in accordance with these three standardized approaches to baseline development according to the Marrakesh Accord. This difference in emission factors comes about partly as a result of including hydroelectric power in the baseline scenario. Hydroelectric resources constitute around 21% of the generation capacity in Egypt, and, if excluding hydropower, the difference between the lowest and the highest baseline is reduced to 18%. Furthermore, since the two variations of the 'historical' baseline option examined result in the highest and the lowest baselines, by disregarding this baseline option altogether the difference between the lowest and the highest is reduced to 16%. The ES3-model, which the Systems Analysis Department at Risoe National Laboratory has developed, makes it possible for this report to explore the project-specific approach to baseline development in some detail. Based on quite disaggregated data on the Egyptian electricity system, including the wind power production

  8. Using biofilms and grazing chironomids (Diptera: Chironomidae) to determine primary production, nitrogen stable isotopic baseline and enrichment within wetlands differing in anthropogenic stressors and located in the Athabasca oil sands region of Alberta

    Energy Technology Data Exchange (ETDEWEB)

    Frederick, K.; Ciborowski, J.J. [Windsor Univ., Windsor, ON (Canada); Wytrykush, C.M. [Syncrude Canada Ltd., Edmonton, AB (Canada)

    2009-07-01

    This presentation reported on a study that investigated the effects of oil sands process materials (OSPM) and construction disturbances on primary production and nitrogen stable isotope enrichment in reclaimed and reference wetlands at oil sands mines in the Athabasca basin. Productivity and food web analyses were instrumental in evaluating the succession and viability of reclaimed wetlands. Primary production was estimated through chlorophyll a (Chl a) concentrations and biomass. Carbon (C) and nitrogen (N) stable isotope ratios were used to identify energy sources, storage and the magnitude and direction of energy transfer within food webs. The objectives were to determine primary productivity, the N baseline, and N enrichment from biofilms and grazing invertebrates colonizing artificial substrates immersed in the water column of two OSPM-affected, two constructed reference and two natural reference wetlands. The lower biomass and Chl a concentrations in OSPM-affected and constructed wetlands suggests that both anthropogenic disturbance and OSPM have an adverse effect on primary productivity and overall wetland function.

  9. Analysis of factors affecting baseline SF-36 Mental Component Summary in Adult Spinal Deformity and its impact on surgical outcomes.

    Science.gov (United States)

    Mmopelwa, Tiro; Ayhan, Selim; Yuksel, Selcen; Nabiyev, Vugar; Niyazi, Asli; Pellise, Ferran; Alanay, Ahmet; Sanchez Perez Grueso, Francisco Javier; Kleinstuck, Frank; Obeid, Ibrahim; Acaroglu, Emre

    2018-03-01

    To identify the factors that affect SF-36 mental component summary (MCS) in patients with adult spinal deformity (ASD) at the time of presentation, and to analyse the effect of SF-36 MCS on clinical outcomes in surgically treated patients. Prospectively collected data from a multicentric ASD database was analysed for baseline parameters. Then, the same database for surgically treated patients with a minimum of 1-year follow-up was analysed to see the effect of baseline SF-36 MCS on treatment results. A clinically useful SF-36 MCS was determined by ROC Curve analysis. A total of 229 patients with the baseline parameters were analysed. A strong correlation between SF-36 MCS and SRS-22, ODI, gender, and diagnosis were found (p baseline SF-36 MCS (p baseline SF-36 MCS in an ASD population are other HRQOL parameters such as SRS-22 and ODI as well as the baseline thoracic kyphosis and gender. This study has also demonstrated that baseline SF-36 MCS does not necessarily have any effect on the treatment results by surgery as assessed by SRS-22 or ODI. Level III, prognostic study. Copyright © 2018 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  10. An Automated Baseline Correction Method Based on Iterative Morphological Operations.

    Science.gov (United States)

    Chen, Yunliang; Dai, Liankui

    2018-05-01

    Raman spectra usually suffer from baseline drift caused by fluorescence or other reasons. Therefore, baseline correction is a necessary and crucial step that must be performed before subsequent processing and analysis of Raman spectra. An automated baseline correction method based on iterative morphological operations is proposed in this work. The method can adaptively determine the structuring element first and then gradually remove the spectral peaks during iteration to get an estimated baseline. Experiments on simulated data and real-world Raman data show that the proposed method is accurate, fast, and flexible for handling different kinds of baselines in various practical situations. The comparison of the proposed method with some state-of-the-art baseline correction methods demonstrates its advantages over the existing methods in terms of accuracy, adaptability, and flexibility. Although only Raman spectra are investigated in this paper, the proposed method is hopefully to be used for the baseline correction of other analytical instrumental signals, such as IR spectra and chromatograms.

  11. 40 CFR 82.10 - Availability of consumption allowances in addition to baseline consumption allowances for class I...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Availability of consumption allowances in addition to baseline consumption allowances for class I controlled substances. 82.10 Section 82.10... STRATOSPHERIC OZONE Production and Consumption Controls § 82.10 Availability of consumption allowances in...

  12. Rationing with baselines

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Moreno-Ternero, Juan D.; Østerdal, Lars Peter Raahave

    2013-01-01

    We introduce a new operator for general rationing problems in which, besides conflicting claims, individual baselines play an important role in the rationing process. The operator builds onto ideas of composition, which are not only frequent in rationing, but also in related problems...... such as bargaining, choice, and queuing. We characterize the operator and show how it preserves some standard axioms in the literature on rationing. We also relate it to recent contributions in such literature....

  13. Mercury baseline levels in Flemish soils (Belgium)

    International Nuclear Information System (INIS)

    Tack, Filip M.G.; Vanhaesebroeck, Thomas; Verloo, Marc G.; Van Rompaey, Kurt; Ranst, Eric van

    2005-01-01

    It is important to establish contaminant levels that are normally present in soils to provide baseline data for pollution studies. Mercury is a toxic element of concern. This study was aimed at assessing baseline mercury levels in soils in Flanders. In a previous study, mercury contents in soils in Oost-Vlaanderen were found to be significantly above levels reported elsewhere. For the current study, observations were extended over two more provinces, West-Vlaanderen and Antwerpen. Ranges of soil Hg contents were distinctly higher in the province Oost-Vlaanderen (interquartile range from 0.09 to 0.43 mg/kg) than in the other provinces (interquartile ranges from 0.7 to 0.13 and 0.7 to 0.15 mg/kg for West-Vlaanderen and Antwerpen, respectively). The standard threshold method was applied to separate soils containing baseline levels of Hg from the data. Baseline concentrations for Hg were characterised by a median of 0.10 mg Hg/kg dry soil, an interquartile range from 0.07 to 0.14 mg/kg and a 90% percentile value of 0.30 mg/kg. The influence of soil properties such as clay and organic carbon contents, and pH on baseline Hg concentrations was not important. Maps of the spatial distribution of Hg levels showed that the province Oost-Vlaanderen exhibited zones with systematically higher Hg soil contents. This may be related to the former presence of many small-scale industries employing mercury in that region. - Increased mercury levels may reflect human activity

  14. SRC-I Project Baseline. [SRC-I demonstration project near Owensboro, Kentucky

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-03-01

    The Process Design Criteria Specification forms the basis for process design for the 6000-TPSD SRC-I Demonstration Plant. It sets forth: basic engineering data, e.g., type and size of plant, feedstocks, product specifications, and atmospheric emission and waste disposal limits; utility conditions; equipment design criteria and sparing philosophy; and estimating criteria for economic considerations. Previously the formal ICRC Document No. 0001-01-002 has been submitted to DOE and revised, as necessary, to be consistent with the SRC-I Project Baseline. Revision 6, dated 19 March 1982, 51 pages, was forwarded to DOE on 19 March 1982.

  15. Tank waste remediation system technical baseline summary description

    International Nuclear Information System (INIS)

    Raymond, R.E.

    1998-01-01

    This document is one of the tools used to develop and control the mission work as depicted in the included figure. This Technical Baseline Summary Description document is the top-level tool for management of the Technical Baseline for waste storage operations

  16. Carbon tetrachloride ERA soil-gas baseline monitoring

    International Nuclear Information System (INIS)

    Fancher, J.D.

    1994-01-01

    From December 1991 through December 1993, Westinghouse Hanford Company performed routine baseline monitoring of selected wells ad soil-gas points twice weekly in the 200 West Area of the Hanford Site. This work supported the carbon Tetrachloride Expedited Response Action (ERA) and provided a solid baseline of volatile organic compound (VOC) concentrations in wells and in the subsurface at the ERA site. As site remediation continues, comparisons to this baseline can be one means of measuring the success of carbon tetrachloride vapor extraction. This report contains observations of the patterns and trends associated with data obtained during soil-gas monitoring at the 200 West Area: Monitoring performed since late 1991 includes monitoring soil-gas probes ad wellheads for volatile organic compounds (VOCs). This report reflects monitoring data collected from December 1991 through December 1993

  17. Hood River production program monitoring and evaluation. Report B: Hood River and Pelton Ladder. Annual report 1996

    International Nuclear Information System (INIS)

    Lambert, M.B.; Jennings, M.; McCanna, J.P.

    1996-01-01

    The Hood River Production Program (HRPP) is jointly implemented by the Confederated Tribes of the Warm Springs Reservation of Oregon (CTWS) and the Oregon Department of Fish and Wildlife (ODFW). The primary goals of the HRPP are (1) to re-establish naturally sustaining spring chinook salmon using Deschutes River stock in the Hood River subbasin, (2) rebuild naturally sustaining runs of summer and winter steelhead in the Hood River subbasin, (3) maintain the genetic characteristics of the populations, and (4) contribute to tribal and non-tribal fisheries, ocean fisheries, and the Northwest Power Planning Council's (NPPC) interim goal of doubling salmon runs

  18. 324 Building Baseline Radiological Characterization

    Energy Technology Data Exchange (ETDEWEB)

    R.J. Reeder, J.C. Cooper

    2010-06-24

    This report documents the analysis of radiological data collected as part of the characterization study performed in 1998. The study was performed to create a baseline of the radiological conditions in the 324 Building.

  19. Digital baseline estimation method for multi-channel pulse height analyzing

    International Nuclear Information System (INIS)

    Xiao Wuyun; Wei Yixiang; Ai Xianyun

    2005-01-01

    The basic features of digital baseline estimation for multi-channel pulse height analysis are introduced. The weight-function of minimum-noise baseline filter is deduced with functional variational calculus. The frequency response of this filter is also deduced with Fourier transformation, and the influence of parameters on amplitude frequency response characteristics is discussed. With MATLAB software, the noise voltage signal from the charge sensitive preamplifier is simulated, and the processing effect of minimum-noise digital baseline estimation is verified. According to the results of this research, digital baseline estimation method can estimate baseline optimally, and it is very suitable to be used in digital multi-channel pulse height analysis. (authors)

  20. Probing Neutrino Properties with Long-Baseline Neutrino Beams

    International Nuclear Information System (INIS)

    Marino, Alysia

    2015-01-01

    This final report on an Early Career Award grant began in April 15, 2010 and concluded on April 14, 2015. Alysia Marino's research is focussed on making precise measurements of neutrino properties using intense accelerator-generated neutrino beams. As a part of this grant, she is collaborating on the Tokai-to-Kamioka (T2K) long-baseline neutrino experiment, currently taking data in Japan, and on the Deep Underground Neutrino Experiment (DUNE) design effort for a future Long-Baseline Neutrino Facility (LBNF) in the US. She is also a member of the NA61/SHINE particle production experiment at CERN, but as that effort is supported by other funds, it will not be discussed further here. T2K was designed to search for the disappearance of muon neutrinos (?_?) and the appearance of electron neutrinos (?_e), using a beam of muon neutrino beam that travels 295 km across Japan towards the Super-Kamiokande detector. In 2011 T2K first reported indications of ?_e appearance, a previously unobserved mode of neutrino oscillations. In the past year, T2K has published a combined analysis of ?_? disappearance and ?_e appearance, and began collecting taking data with a beam of anti-neutrinos, instead of neutrinos, to search for hints of violation of the CP symmetry of the universe. The proposed DUNE experiment has similar physics goals to T2K, but will be much more sensitive due to its more massive detectors and new higher-intensity neutrino beam. This effort will be very high-priority particle physics project in the US over the next decade.

  1. First Grade Baseline Evaluation

    Science.gov (United States)

    Center for Innovation in Assessment (NJ1), 2013

    2013-01-01

    The First Grade Baseline Evaluation is an optional tool that can be used at the beginning of the school year to help teachers get to know the reading and language skills of each student. The evaluation is composed of seven screenings. Teachers may use the entire evaluation or choose to use those individual screenings that they find most beneficial…

  2. Estimating the Cold War mortgage: The 1995 baseline environmental management report. Volume 1

    International Nuclear Information System (INIS)

    1995-03-01

    This is the first annual report on the activities and potentials costs required to address the waste, contamination, and surplus nuclear facilities that are the responsibility of the Department of Energy's Environmental Management program. The Department's Office of Environmental Management, established in 1989, manages one of the largest environmental programs in the world--with more than 130 sites and facilities in over 30 States and territories. The primary focus of the program is to reduce health and safety risks from radioactive waste and contamination resulting from the production, development, and testing of nuclear weapons. The program also is responsible for the environmental legacy from, and ongoing waste management for, nuclear energy research and development, and basic science research. In an attempt to better oversee this effort, Congress required the Secretary of Energy to submit a Baseline Environmental Management Report with annual updates. The 1995 Baseline Environmental Management Report provides life-cycle cost estimates, tentative schedules, and projected activities necessary to complete the Environmental Management program

  3. Esophageal acid exposure decreases intraluminal baseline impedance levels

    NARCIS (Netherlands)

    Kessing, Boudewijn F.; Bredenoord, Albert J.; Weijenborg, Pim W.; Hemmink, Gerrit J. M.; Loots, Clara M.; Smout, A. J. P. M.

    2011-01-01

    Intraluminal baseline impedance levels are determined by the conductivity of the esophageal wall and can be decreased in gastroesophageal reflux disease (GERD) patients. The aim of this study was to investigate the baseline impedance in GERD patients, on and off proton pump inhibitor (PPI), and in

  4. Measuring cognitive change with ImPACT: the aggregate baseline approach.

    Science.gov (United States)

    Bruce, Jared M; Echemendia, Ruben J; Meeuwisse, Willem; Hutchison, Michael G; Aubry, Mark; Comper, Paul

    2017-11-01

    The Immediate Post-Concussion Assessment and Cognitive Test (ImPACT) is commonly used to assess baseline and post-injury cognition among athletes in North America. Despite this, several studies have questioned the reliability of ImPACT when given at intervals employed in clinical practice. Poor test-retest reliability reduces test sensitivity to cognitive decline, increasing the likelihood that concussed athletes will be returned to play prematurely. We recently showed that the reliability of ImPACT can be increased when using a new composite structure and the aggregate of two baselines to predict subsequent performance. The purpose of the present study was to confirm our previous findings and determine whether the addition of a third baseline would further increase the test-retest reliability of ImPACT. Data from 97 English speaking professional hockey players who had received at least 4 ImPACT baseline evaluations were extracted from a National Hockey League Concussion Program database. Linear regression was used to determine whether each of the first three testing sessions accounted for unique variance in the fourth testing session. Results confirmed that the aggregate baseline approach improves the psychometric properties of ImPACT, with most indices demonstrating adequate or better test-retest reliability for clinical use. The aggregate baseline approach provides a modest clinical benefit when recent baselines are available - and a more substantial benefit when compared to approaches that obtain baseline measures only once during the course of a multi-year playing career. Pending confirmation in diverse samples, neuropsychologists are encouraged to use the aggregate baseline approach to best quantify cognitive change following sports concussion.

  5. Study on the calibration and optimization of double theodolites baseline

    Science.gov (United States)

    Ma, Jing-yi; Ni, Jin-ping; Wu, Zhi-chao

    2018-01-01

    For the double theodolites measurement system baseline as the benchmark of the scale of the measurement system and affect the accuracy of the system, this paper puts forward a method for calibration and optimization of the double theodolites baseline. Using double theodolites to measure the known length of the reference ruler, and then reverse the baseline formula. Based on the error propagation law, the analyses show that the baseline error function is an important index to measure the accuracy of the system, and the reference ruler position, posture and so on have an impact on the baseline error. The optimization model is established and the baseline error function is used as the objective function, and optimizes the position and posture of the reference ruler. The simulation results show that the height of the reference ruler has no effect on the baseline error; the posture is not uniform; when the reference ruler is placed at x=500mm and y=1000mm in the measurement space, the baseline error is the smallest. The experimental results show that the experimental results are consistent with the theoretical analyses in the measurement space. In this paper, based on the study of the placement of the reference ruler, for improving the accuracy of the double theodolites measurement system has a reference value.

  6. STATUS OF THE US LONG BASELINE NEUTRINO EXPERIMENT STUDY.

    Energy Technology Data Exchange (ETDEWEB)

    BISHAI,M.

    2006-09-21

    The US Long Baseline Neutrino Experiment Study was commissioned jointly by Brookhaven National Laboratory and Fermi National Accelerator Laboratory to investigate the potential for future U.S. based long baseline neutrino oscillation experiments beyond the currently planned program. The Study focused on MW class convention at neutrino beams that can be produced at Fermilab or BNL. The experimental baselines are based on two possible detector locations: (1) off-axis to the existing Fermilab NuMI beamline at baselines of 700 to 810 km and (2) NSF's proposed future Deep Underground Science and Engineering Laboratory (DUSEL) at baselines greater than 1000 km. Two detector technologies are considered: a megaton class Water Cherenkov detector deployed deep underground at a DUSEL site, or a 100kT Liquid Argon Time-Projection Chamber (TPC) deployed on the surface at any of the proposed sites. The physics sensitivities of the proposed experiments are summarized. We find that conventional horn focused wide-band neutrino beam options from Fermilab or BNL aimed at a massive detector with a baseline of > 1000 km have the best sensitivity to CP violation and the neutrino mass hierarchy for values of the mixing angle {theta}{sub 13} down to 2.2{sup o}.

  7. Baselines For Land-Use Change In The Tropics: Application ToAvoided Deforestation Projects

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Sandra; Hall, Myrna; Andrasko, Ken; Ruiz, Fernando; Marzoli, Walter; Guerrero, Gabriela; Masera, Omar; Dushku, Aaron; Dejong,Ben; Cornell, Joseph

    2007-06-01

    Although forest conservation activities particularly in thetropics offer significant potential for mitigating carbon emissions,these types of activities have faced obstacles in the policy arena causedby the difficulty in determining key elements of the project cycle,particularly the baseline. A baseline for forest conservation has twomain components: the projected land-use change and the correspondingcarbon stocks in the applicable pools such as vegetation, detritus,products and soil, with land-use change being the most difficult toaddress analytically. In this paper we focus on developing and comparingthree models, ranging from relatively simple extrapolations of pasttrends in land use based on simple drivers such as population growth tomore complex extrapolations of past trends using spatially explicitmodels of land-use change driven by biophysical and socioeconomicfactors. The three models of the latter category used in the analysis atregional scale are The Forest Area Change (FAC) model, the Land Use andCarbon Sequestration (LUCS) model, and the Geographical Modeling (GEOMOD)model. The models were used to project deforestation in six tropicalregions that featured different ecological and socioeconomic conditions,population dynamics, and uses of the land: (1) northern Belize; (2) SantaCruz State, Bolivia; (3) Parana State in Brazil; (4) Campeche, Mexico;(5) Chiapas, Mexico; and (6) Michoacan, Mexico. A comparison of all modeloutputs across all six regions shows that each model produced quitedifferent deforestation baseline. In general, the simplest FAC model,applied at the national administrative-unit scale, projected the highestamount of forest loss (four out of six) and the LUCS model the leastamount of loss (four out of five). Based on simulations of GEOMOD, wefound that readily observable physical and biological factors as well asdistance to areas of past disturbance were each about twice as importantas either sociological/demographic or economic

  8. Seasonal cycles of pelagic production and consumption

    Science.gov (United States)

    Longhurst, Alan

    Comprehensive seasonal cycles of production and consumption in the pelagial require the ocean to be partitioned. This can be done rationally at two levels: into four primary ecological domains (three oceanic and one coastal), or about fifty biogeochemical provinces. The domains differ in their characteristic seasonal cycles of stability, nutrient supply and illumination, while provinces are defined by ocean currents, fronts, topography and recurrent features in the sea surface chlorophyll field. For each of these compartments, seasonal cycles of photic depth, primary production and accumulation (or loss) of algal biomass were obtained from the climatological CZCS chlorophyll field and other data and these, together with mixed layer depths, rendered characteristic seasonal cycles of production and consumption, which can be grouped into eight models: i - polar irradiance-mediated production peak; ii - nutrient-limited spring production peak; iii - winter-spring production with nutrient limitation; iv - small amplitude response to trade wind seasonality; v - large amplitude response to monsoon reversal; vi - canonical spring-fall blooms of mid-latitude continental shelves; vii - topography-forced summer production; viii - intermittent production at coastal divergences. For higher latitudes, these models suggest that the observed late-summer ‘blooms’ result not from a renewal of primary production rate, but from a relaxation of grazing pressure; in mid-latitudes, the observed ‘winter’ bloom represents chlorophyll accumulation at a season when loss terms are apparently smaller than during the period of peak primary production rate which occurs later, in spring. Where an episodic seasonal increase in rate of primary production occurs, as in the Arabian Sea, algal biomass accumulation may brief, lasting only until consumption is fully re-established. Only in the low latitude oligotrophic ocean are production and consumption perennially and closely coupled.

  9. Placental baseline conditions modulate the hyperoxic BOLD-MRI response.

    Science.gov (United States)

    Sinding, Marianne; Peters, David A; Poulsen, Sofie S; Frøkjær, Jens B; Christiansen, Ole B; Petersen, Astrid; Uldbjerg, Niels; Sørensen, Anne

    2018-01-01

    Human pregnancies complicated by placental dysfunction may be characterized by a high hyperoxic Blood oxygen level-dependent (BOLD) MRI response. The pathophysiology behind this phenomenon remains to be established. The aim of this study was to evaluate whether it is associated with altered placental baseline conditions, including a lower oxygenation and altered tissue morphology, as estimated by the placental transverse relaxation time (T2*). We included 49 normal pregnancies (controls) and 13 pregnancies complicated by placental dysfunction (cases), defined by a birth weight baseline BOLD)/baseline BOLD) from a dynamic single-echo gradient-recalled echo (GRE) MRI sequence and the absolute ΔT2* (hyperoxic T2*- baseline T2*) from breath-hold multi-echo GRE sequences. In the control group, the relative ΔBOLD response increased during gestation from 5% in gestational week 20 to 20% in week 40. In the case group, the relative ΔBOLD response was significantly higher (mean Z-score 4.94; 95% CI 2.41, 7.47). The absolute ΔT2*, however, did not differ between controls and cases (p = 0.37), whereas the baseline T2* was lower among cases (mean Z-score -3.13; 95% CI -3.94, -2.32). Furthermore, we demonstrated a strong negative linear correlation between the Log 10 ΔBOLD response and the baseline T2* (r = -0.88, p baseline conditions, as the absolute increase in placental oxygenation (ΔT2*) does not differ between groups. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Energy and emission scenarios for China in the 21st century. Exploration of baseline development and mitigation options

    NARCIS (Netherlands)

    Vuuren DP van; Fengqi Zhou; Vries HJM de; Kejun Jiang; Graveland C; Yun Li; Energy Research Institute,; MNV

    2001-01-01

    The purpose of the study reported here was to explore possible baseline developments and available options for mitigating emissions in China. The first part of the report deals with an analysis and overview of available data on historic energy production and consumption trends and current energy

  11. Level 3 Baseline Risk Assessment for Building 3515 at Oak Ridge National Lab., Oak Ridge, TN

    Energy Technology Data Exchange (ETDEWEB)

    Wollert, D.A.; Cretella, F.M.; Golden, K.M. [Univ. of Tennessee, Knoxville, TN (United States)] [and others

    1995-08-01

    The baseline risk assessment for the Fission Product Pilot Plant (Building 3515) at the Oak Ridge National laboratory (ORNL) provides the Decontamination and Decommissioning (D&D) Program at ORNL and Building 3515 project managers with information concerning the results of the Level 3 baseline risk assessment performed for this building. The document was prepared under Work Breakdown Structure 1.4.12.6.2.01 (Activity Data Sheet 3701, Facilities D&D) and includes information on the potential long-term impacts to human health and the environment if no action is taken to remediate Building 3515. Information provided in this document forms the basis for the development of remedial alternatives and the no-action risk portion of the Engineering Evaluation/Cost Analysis report.

  12. Level 3 Baseline Risk Assessment for Building 3515 at Oak Ridge National Lab., Oak Ridge, TN

    International Nuclear Information System (INIS)

    Wollert, D.A.; Cretella, F.M.; Golden, K.M.

    1995-08-01

    The baseline risk assessment for the Fission Product Pilot Plant (Building 3515) at the Oak Ridge National laboratory (ORNL) provides the Decontamination and Decommissioning (D ampersand D) Program at ORNL and Building 3515 project managers with information concerning the results of the Level 3 baseline risk assessment performed for this building. The document was prepared under Work Breakdown Structure 1.4.12.6.2.01 (Activity Data Sheet 3701, Facilities D ampersand D) and includes information on the potential long-term impacts to human health and the environment if no action is taken to remediate Building 3515. Information provided in this document forms the basis for the development of remedial alternatives and the no-action risk portion of the Engineering Evaluation/Cost Analysis report

  13. Reestablishing microglia function : Good news for Alzheimer's therapy?

    NARCIS (Netherlands)

    Biber, Knut

    2017-01-01

    Alzheimer's disease (AD) is the most common form of age-related neurodegenerative disease resulting in dementia. The current notion is that AD is based on a pathological plaque-forming accumulation of amyloid- (A) peptides that originate from a disturbed balance between production and removal of A

  14. Effect of Soil Filtration and Ozonation in the Change of Baseline Toxicity in Wastewater Spiked with Organic Micro-pollutants

    KAUST Repository

    Gan, Alexander

    2012-07-01

    Bioassays for baseline toxicity, which measure toxicants’ non-specific effects, have been shown in previous studies to effectively correlate with the increased presence of pharmaceuticals, personal care products, endocrine-disrupting compounds, and other synthetic organics in treated sewage effluent. This study investigated how the baseline toxicity of anthropogenic compounds-spiked wastewater changed during the treatment of biofiltration and ozone oxidation, as measured by the bioluminescence inhibition of the Vibrio fischeri bacterium. The water quality parameters of dissolved organic carbon, seven common anions, and fluorescence spectroscopy were used to corroborate and collate with the toxicity results. Water quality was evaluated on two bench-scale soil filtration columns, which were configured for pre-ozonation and post-ozonation. Both systems’ soil aerobically removed similar amounts of dissolved organic carbon, and the reduction ranged between 57.7% and 62.1% for the post-ozonation and pre-ozonation systems, respectively. Biological removal of DOC, protein-like, humic-like, and soluble microbial product-like material was highest in the first 28.5 cm of each 114 cm-long system. While bioluminescence inhibition showed that ozonation was effective at lowering baseline toxicity, this study’s bioassay procedure was a very poor indicator of soil filtration treatment; both system’s effluents were significantly more toxic than their non-ozonated influents.

  15. Baseline restoration technique based on symmetrical zero-area trapezoidal pulse shaper

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Guoqiang, E-mail: 24829500@qq.com [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China); Yang, Jian, E-mail: 22105653@qq.com [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China); Hu, Tianyu; Ge, Liangquan [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China); Ouyang, Xiaoping [Northwest Institute of Nuclear Technology, Xi’an 710024,China (China); Zhang, Qingxian; Gu, Yi [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China)

    2017-06-21

    Since the baseline of the unipolar pulse shaper have the direct-current (DC) offset and drift, an additional baseline estimator is need to obtain baseline values in real-time. The bipolar zero-area (BZA) pulse shapers can be used for baseline restoration, but they cannot restrain the baseline drift due to their asymmetrical shape. In this study, three trapezoids are synthesized as a symmetrical zero-area (SZA) shape, which can remove the DC offset and restrain the baseline drift. This baseline restoration technique can be easily implemented in digital pulse processing (DPP) systems base on the recursive algorithm. To strengthen our approach, the iron's characteristic x-ray was detected using a Si-PIN diode detector. Compared with traditional trapezoidal pulse shapers, the SZA trapezoidal pulse shaper improved the energy resolution from 237 eV to 216 eV for the 6.403 keV Kα peak.

  16. A Fully Customized Baseline Removal Framework for Spectroscopic Applications.

    Science.gov (United States)

    Giguere, Stephen; Boucher, Thomas; Carey, C J; Mahadevan, Sridhar; Dyar, M Darby

    2017-07-01

    The task of proper baseline or continuum removal is common to nearly all types of spectroscopy. Its goal is to remove any portion of a signal that is irrelevant to features of interest while preserving any predictive information. Despite the importance of baseline removal, median or guessed default parameters are commonly employed, often using commercially available software supplied with instruments. Several published baseline removal algorithms have been shown to be useful for particular spectroscopic applications but their generalizability is ambiguous. The new Custom Baseline Removal (Custom BLR) method presented here generalizes the problem of baseline removal by combining operations from previously proposed methods to synthesize new correction algorithms. It creates novel methods for each technique, application, and training set, discovering new algorithms that maximize the predictive accuracy of the resulting spectroscopic models. In most cases, these learned methods either match or improve on the performance of the best alternative. Examples of these advantages are shown for three different scenarios: quantification of components in near-infrared spectra of corn and laser-induced breakdown spectroscopy data of rocks, and classification/matching of minerals using Raman spectroscopy. Software to implement this optimization is available from the authors. By removing subjectivity from this commonly encountered task, Custom BLR is a significant step toward completely automatic and general baseline removal in spectroscopic and other applications.

  17. High Baseline Postconcussion Symptom Scores and Concussion Outcomes in Athletes.

    Science.gov (United States)

    Custer, Aimee; Sufrinko, Alicia; Elbin, R J; Covassin, Tracey; Collins, Micky; Kontos, Anthony

    2016-02-01

    Some healthy athletes report high levels of baseline concussion symptoms, which may be attributable to several factors (eg, illness, personality, somaticizing). However, the role of baseline symptoms in outcomes after sport-related concussion (SRC) has not been empirically examined. To determine if athletes with high symptom scores at baseline performed worse than athletes without baseline symptoms on neurocognitive testing after SRC. Cohort study. High school and collegiate athletic programs. A total of 670 high school and collegiate athletes participated in the study. Participants were divided into groups with either no baseline symptoms (Postconcussion Symptom Scale [PCSS] score = 0, n = 247) or a high level of baseline symptoms (PCSS score > 18 [top 10% of sample], n = 68). Participants were evaluated at baseline and 2 to 7 days after SRC with the Immediate Post-concussion Assessment and Cognitive Test and PCSS. Outcome measures were Immediate Post-concussion Assessment and Cognitive Test composite scores (verbal memory, visual memory, visual motor processing speed, and reaction time) and total symptom score on the PCSS. The groups were compared using repeated-measures analyses of variance with Bonferroni correction to assess interactions between group and time for symptoms and neurocognitive impairment. The no-symptoms group represented 38% of the original sample, whereas the high-symptoms group represented 11% of the sample. The high-symptoms group experienced a larger decline from preinjury to postinjury than the no-symptoms group in verbal (P = .03) and visual memory (P = .05). However, total concussion-symptom scores increased from preinjury to postinjury for the no-symptoms group (P = .001) but remained stable for the high-symptoms group. Reported baseline symptoms may help identify athletes at risk for worse outcomes after SRC. Clinicians should examine baseline symptom levels to better identify patients for earlier referral and treatment for their

  18. Baseline effects on carbon footprints of biofuels: The case of wood

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Eric, E-mail: johnsonatlantic@gmail.com [Atlantic Consulting, 8136 Gattikon (Switzerland); Tschudi, Daniel [ETH, Berghaldenstrasse 46, 8800 Thalwil (Switzerland)

    2012-11-15

    As biofuel usage has boomed over the past decade, so has research and regulatory interest in its carbon accounting. This paper examines one aspect of that carbon accounting: the baseline, i.e. the reference case against which other conditions or changes can be compared. A literature search and analysis identified four baseline types: no baseline; reference point; marginal fossil fuel; and biomass opportunity cost. The fourth one, biomass opportunity cost, is defined in more detail, because this is not done elsewhere in the literature. The four baselines are then applied to the carbon footprint of a wood-fired power plant. The footprint of the resulting wood-fired electricity varies dramatically, according to the type of baseline. Baseline type is also found to be the footprint's most significant sensitivity. Other significant sensitivities are: efficiency of the power plant; the growth (or re-growth) rate of the forest that supplies the wood; and the residue fraction of the wood. Length of the policy horizon is also an important factor in determining the footprint. The paper concludes that because of their significance and variability, baseline choices should be made very explicit in biofuel carbon footprints. - Highlights: Black-Right-Pointing-Pointer Four baseline types for biofuel footprinting are identified. Black-Right-Pointing-Pointer One type, 'biomass opportunity cost', is defined mathematically and graphically. Black-Right-Pointing-Pointer Choice of baseline can dramatically affect the footprint result. Black-Right-Pointing-Pointer The 'no baseline' approach is not acceptable. Black-Right-Pointing-Pointer Choice between the other three baselines depends on the question being addressed.

  19. Automated baseline change detection phase I. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    The Automated Baseline Change Detection (ABCD) project is supported by the DOE Morgantown Energy Technology Center (METC) as part of its ER&WM cross-cutting technology program in robotics. Phase 1 of the Automated Baseline Change Detection project is summarized in this topical report. The primary objective of this project is to apply robotic and optical sensor technology to the operational inspection of mixed toxic and radioactive waste stored in barrels, using Automated Baseline Change Detection (ABCD), based on image subtraction. Absolute change detection is based on detecting any visible physical changes, regardless of cause, between a current inspection image of a barrel and an archived baseline image of the same barrel. Thus, in addition to rust, the ABCD system can also detect corrosion, leaks, dents, and bulges. The ABCD approach and method rely on precise camera positioning and repositioning relative to the barrel and on feature recognition in images. In support of this primary objective, there are secondary objectives to determine DOE operational inspection requirements and DOE system fielding requirements.

  20. Automated baseline change detection phase I. Final report

    International Nuclear Information System (INIS)

    1995-12-01

    The Automated Baseline Change Detection (ABCD) project is supported by the DOE Morgantown Energy Technology Center (METC) as part of its ER ampersand WM cross-cutting technology program in robotics. Phase 1 of the Automated Baseline Change Detection project is summarized in this topical report. The primary objective of this project is to apply robotic and optical sensor technology to the operational inspection of mixed toxic and radioactive waste stored in barrels, using Automated Baseline Change Detection (ABCD), based on image subtraction. Absolute change detection is based on detecting any visible physical changes, regardless of cause, between a current inspection image of a barrel and an archived baseline image of the same barrel. Thus, in addition to rust, the ABCD system can also detect corrosion, leaks, dents, and bulges. The ABCD approach and method rely on precise camera positioning and repositioning relative to the barrel and on feature recognition in images. In support of this primary objective, there are secondary objectives to determine DOE operational inspection requirements and DOE system fielding requirements

  1. Vegetation Parameter Extraction Using Dual Baseline Polarimetric SAR Interferometry Data

    Science.gov (United States)

    Zhang, H.; Wang, C.; Chen, X.; Tang, Y.

    2009-04-01

    For vegetation parameter inversion, the single baseline polarimetric SAR interferometry (POLinSAR) technique, such as the three-stage method and the ESPRIT algorithm, is limited by the observed data with the minimum ground to volume amplitude ration, which effects the estimation of the effective phase center for the vegetation canopy or the surface, and thus results in the underestimated vegetation height. In order to remove this effect of the single baseline inversion techniques in some extend, another baseline POLinSAR data is added on vegetation parameter estimation in this paper, and a dual baseline POLinSAR technique for the extraction of the vegetation parameter is investigated and improved to reduce the dynamic bias for the vegetation parameter estimation. Finally, the simulated data and real data are used to validate this dual baseline technique.

  2. 78 FR 29784 - New Postal Product

    Science.gov (United States)

    2013-05-21

    ... POSTAL REGULATORY COMMISSION [Docket No. CP2013-62; Order No. 1716] New Postal Product AGENCY... filing concerning the addition of Global Expedited Package Services 3 Contract to the competitive product... GEPS 3 product on grounds of functional equivalence to a previously approved baseline agreement. Id. at...

  3. Information architecture. Volume 2, Part 1: Baseline analysis summary

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    The Department of Energy (DOE) Information Architecture, Volume 2, Baseline Analysis, is a collaborative and logical next-step effort in the processes required to produce a Departmentwide information architecture. The baseline analysis serves a diverse audience of program management and technical personnel and provides an organized way to examine the Department`s existing or de facto information architecture. A companion document to Volume 1, The Foundations, it furnishes the rationale for establishing a Departmentwide information architecture. This volume, consisting of the Baseline Analysis Summary (part 1), Baseline Analysis (part 2), and Reference Data (part 3), is of interest to readers who wish to understand how the Department`s current information architecture technologies are employed. The analysis identifies how and where current technologies support business areas, programs, sites, and corporate systems.

  4. Satellite-Surface Perspectives of Air Quality and Aerosol-Cloud Effects on the Environment: An Overview of 7-SEAS BASELInE

    Science.gov (United States)

    Tsay, Si-Chee; Maring, Hal B.; Lin, Neng-Huei; Buntoung, Sumaman; Chantara, Somporn; Chuang, Hsiao-Chi; Gabriel, Philip M.; Goodloe, Colby S.; Holben, Brent N.; Hsiao, Ta-Chih; hide

    2016-01-01

    The objectives of 7-SEASBASELInE (Seven SouthEast Asian Studies Biomass-burning Aerosols and Stratocumulus Environment: Lifecycles and Interactions Experiment) campaigns in spring 2013-2015 were to synergize measurements from uniquely distributed ground-based networks (e.g., AERONET (AErosol RObotic NETwork)), MPLNET ( NASA Micro-Pulse Lidar Network)) and sophisticated platforms (e.g.,SMARTLabs (Surface-based Mobile Atmospheric Research and Testbed Laboratories), regional contributing instruments), along with satellite observations retrievals and regional atmospheric transport chemical models to establish a critically needed database, and to advance our understanding of biomass-burning aerosols and trace gases in Southeast Asia (SEA). We present a satellite-surface perspective of 7-SEASBASELInE and highlight scientific findings concerning: (1) regional meteorology of moisture fields conducive to the production and maintenance of low-level stratiform clouds over land; (2) atmospheric composition in a biomass-burning environment, particularly tracers-markers to serve as important indicators for assessing the state and evolution of atmospheric constituents; (3) applications of remote sensing to air quality and impact on radiative energetics, examining the effect of diurnal variability of boundary-layer height on aerosol loading; (4) aerosol hygroscopicity and ground-based cloud radar measurements in aerosol-cloud processes by advanced cloud ensemble models; and (5) implications of air quality, in terms of toxicity of nanoparticles and trace gases, to human health. This volume is the third 7-SEAS special issue (after Atmospheric Research, vol. 122, 2013; and Atmospheric Environment, vol. 78, 2013) and includes 27 papers published, with emphasis on air quality and aerosol-cloud effects on the environment. BASELInE observations of stratiform clouds over SEA are unique, such clouds are embedded in a heavy aerosol-laden environment and feature characteristically greater

  5. Validity and Reliability of Baseline Testing in a Standardized Environment.

    Science.gov (United States)

    Higgins, Kathryn L; Caze, Todd; Maerlender, Arthur

    2017-08-11

    The Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) is a computerized neuropsychological test battery commonly used to determine cognitive recovery from concussion based on comparing post-injury scores to baseline scores. This model is based on the premise that ImPACT baseline test scores are a valid and reliable measure of optimal cognitive function at baseline. Growing evidence suggests that this premise may not be accurate and a large contributor to invalid and unreliable baseline test scores may be the protocol and environment in which baseline tests are administered. This study examined the effects of a standardized environment and administration protocol on the reliability and performance validity of athletes' baseline test scores on ImPACT by comparing scores obtained in two different group-testing settings. Three hundred-sixty one Division 1 cohort-matched collegiate athletes' baseline data were assessed using a variety of indicators of potential performance invalidity; internal reliability was also examined. Thirty-one to thirty-nine percent of the baseline cases had at least one indicator of low performance validity, but there were no significant differences in validity indicators based on environment in which the testing was conducted. Internal consistency reliability scores were in the acceptable to good range, with no significant differences between administration conditions. These results suggest that athletes may be reliably performing at levels lower than their best effort would produce. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Baseline effects on carbon footprints of biofuels: The case of wood

    International Nuclear Information System (INIS)

    Johnson, Eric; Tschudi, Daniel

    2012-01-01

    As biofuel usage has boomed over the past decade, so has research and regulatory interest in its carbon accounting. This paper examines one aspect of that carbon accounting: the baseline, i.e. the reference case against which other conditions or changes can be compared. A literature search and analysis identified four baseline types: no baseline; reference point; marginal fossil fuel; and biomass opportunity cost. The fourth one, biomass opportunity cost, is defined in more detail, because this is not done elsewhere in the literature. The four baselines are then applied to the carbon footprint of a wood-fired power plant. The footprint of the resulting wood-fired electricity varies dramatically, according to the type of baseline. Baseline type is also found to be the footprint's most significant sensitivity. Other significant sensitivities are: efficiency of the power plant; the growth (or re-growth) rate of the forest that supplies the wood; and the residue fraction of the wood. Length of the policy horizon is also an important factor in determining the footprint. The paper concludes that because of their significance and variability, baseline choices should be made very explicit in biofuel carbon footprints. - Highlights: ► Four baseline types for biofuel footprinting are identified. ► One type, ‘biomass opportunity cost’, is defined mathematically and graphically. ► Choice of baseline can dramatically affect the footprint result. ► The ‘no baseline’ approach is not acceptable. ► Choice between the other three baselines depends on the question being addressed.

  7. Long baseline neutrino oscillation experiments

    International Nuclear Information System (INIS)

    Gallagher, H.

    2006-01-01

    In this paper I will review briefly the experimental results which established the existence of neutrino mixing, the current generation of long baseline accelerator experiments, and the prospects for the future. In particular I will focus on the recent analysis of the MINOS experiment. (author)

  8. Baseline composition of solar energetic particles

    International Nuclear Information System (INIS)

    Meyer, J.

    1985-01-01

    We analyze all existing spacecraft observations of the highly variable heavy element composition of solar energetic particles (SEP) during non- 3 He-rich events. All data show the imprint of an ever-present basic composition pattern (dubbed ''mass-unbiased baseline'' SEP composition) that differs from the photospheric composition by a simple bias related to first ionization potential (FIP). In each particular observation, this mass-unbiased baseline composition is being distorted by an additional bias, which is always a monotonic function of mass (or Z). This latter bias varies in amplitude and even sign from observation to observation. To first order, it seems related to differences in the A/Z* ratio between elements (Z* = mean effective charge)

  9. Postanaesthetic tear production and ocular irritation in cats.

    Science.gov (United States)

    Peche, N; Köstlin, R; Reese, S; Pieper, K

    2015-01-01

    General anaesthesia significantly reduces tear production and normal values are not immediately re-established on ending anaesthesia. Therefore, adequate protection of the cornea has to be assured during the perianaesthetic period. There are various methods available, including taping of the eyelids and the application of eye ointments, gels and drops. In human medicine studies, different formulations were found to induce signs of ocular irritation. The aim of the present study was to determine tear production in cats after general anaesthesia, and to identify possible causes of irritation. Tear production was determined in 41 cats after general anaesthesia and eyes were examined for signs of irritation. Two different anaesthetic protocols were used. To protect the cornea, an ointment and gel were applied to the right and left eyes, respectively. Postoperatively, tear production was significantly reduced for 6 hours and 18 hours in the right and left eyes, respectively. Two hours after anaesthesia, blepharospasm of the right eye was observed in 92.7% (n = 38) of the cats. In contrast, the left eye was always held open. This study demonstrated that tear production in cats is significantly decreased both during and after anaesthesia. The degree of reduction was independent of the anaesthetic protocol. Both the eye ointment and gel proved effective in protecting the corneal surface. However, eye gel use is recommended because the eye ointment consistently caused an irritation comparable to the foreign-body sensation reported in humans.

  10. Precision forestry for pulpwood re-establishment silviculture | Pallett ...

    African Journals Online (AJOL)

    In a global context, wood is a commodity product and an ongoing strategy of reduction in the unit cost of timber delivered to mill gate and understanding wood properties to add value in the mill, is important to low cost “fit for purpose” fibre and to enhancing our competitive advantage. In addition, the plantation area is largely ...

  11. Magical properties of a 2540 km baseline superbeam experiment

    International Nuclear Information System (INIS)

    Raut, Sushant K.; Singh, Ravi Shanker; Uma Sankar, S.

    2011-01-01

    Lack of any information on the CP violating phase δ CP weakens our ability to determine neutrino mass hierarchy. Magic baseline of 7500 km was proposed to overcome this problem. However, to obtain large enough fluxes, at this very long baseline, one needs new techniques of generating high intensity neutrino beams. In this Letter, we highlight the magical properties of a 2540 km baseline. At such a baseline, using a narrow band neutrino superbeam whose no oscillation event rate peaks around the energy 3.5 GeV, we can determine neutrino mass hierarchy independently of the CP phase. For sin 2 2θ 13 ≥0.05, a very modest exposure of 10 Kiloton-years is sufficient to determine the hierarchy. For 0.02≤sin 2 2θ 13 ≤0.05, an exposure of about 100 Kiloton-years is needed.

  12. Dynamic baseline detection method for power data network service

    Science.gov (United States)

    Chen, Wei

    2017-08-01

    This paper proposes a dynamic baseline Traffic detection Method which is based on the historical traffic data for the Power data network. The method uses Cisco's NetFlow acquisition tool to collect the original historical traffic data from network element at fixed intervals. This method uses three dimensions information including the communication port, time, traffic (number of bytes or number of packets) t. By filtering, removing the deviation value, calculating the dynamic baseline value, comparing the actual value with the baseline value, the method can detect whether the current network traffic is abnormal.

  13. Reestablecimiento de Choromytilus chorus (Molina, 1782 (Bivalvia: Mytilidae en el norte de Chile Reestablishment of Choromytilus chorus (Molina, 1782 (Bivalvia: Mytilidae in northern Chile

    Directory of Open Access Journals (Sweden)

    Miguel Avendaño

    2011-07-01

    Full Text Available Hasta fines del siglo pasado no existían registros de la presencia de Choromytilus chorus al norte de los 23°S, pese a antecedentes que señalaban su existencia en épocas pasadas. Ciertos cambios relacionados con las masas de agua costeras de esta zona, habrían generado la ausencia o escasez que presentaba el entorno costero actual. Sin embargo, hace una década atrás, su presencia en el norte de Chile, comienza a tener connotación pesquera. En el presente trabajo se confirma su reestablecimiento en las regiones de Antofagasta y Tarapacá, mediante prospecciones realizadas en seis lugares donde se registró su presencia, así como mediante la captación de semilla en colectores suspendidos. Se indica interacción con Aulacomya ater, a la cual ha desplazado a estratos más profundos, mientras que su reestablecimiento, iniciado en las regiones de Atacama y Antofagasta, y que se amplió posteriormente a la región de Tarapacá; permite postular la hipótesis que la dinámica de estos bancos, respondería a una estructura de metapoblación, dado el sistema de corrientes y vientos que predominan en la zona norte, permitiendo la advección larval de poblaciones existentes en la región de Coquimbo.Despite indications of its presence in past ages, until the end of the last century, no records showed Choromytilus chorus north of 23°S. Certain changes related to coastal water masses in the zone could be responsible for the present lack or scarcity of this species in the coastal area. However, a decade ago, this species appeared in northern Chile in the context of fisheries. This study confirms the re-establishment of C. chorus in the Antofagasta and Tarapaca regions through surveys at six sites where the species had been registered and spat collection using suspended collectors. This species has interacted with Aulacomya ater, displacing it towards deeper habitats. The re-establishment of C. chorus began in the Atacama and Antofagasta regions and

  14. Forecasting Sensorimotor Adaptability from Baseline Inter-Trial Correlations

    Science.gov (United States)

    Beaton, K. H.; Bloomberg, J. J.

    2014-01-01

    One of the greatest challenges surrounding adaptation to the spaceflight environment is the large variability in symptoms, and corresponding functional impairments, from one crewmember to the next. This renders preflight training and countermeasure development difficult, as a "one-size-fits-all" approach is inappropriate. Therefore, it would be highly advantageous to know ahead of time which crewmembers might have more difficulty adjusting to the novel g-levels inherent to spaceflight. Such knowledge could guide individually customized countermeasures, which would enable more efficient use of crew time, both preflight and inflight, and provide better outcomes. The primary goal of this project is to look for a baseline performance metric that can forecast sensorimotor adaptability without exposure to an adaptive stimulus. We propose a novel hypothesis that considers baseline inter-trial correlations, the trial-to-trial fluctuations in motor performance, as a predictor of individual sensorimotor adaptive capabilities. To-date, a strong relationship has been found between baseline inter-trial correlations and adaptability in two oculomotor systems. For this project, we will explore an analogous predictive mechanism in the locomotion system. METHODS: Baseline Inter-trial Correlations: Inter-trial correlations specify the relationships among repeated trials of a given task that transpire as a consequence of correcting for previous performance errors over multiple timescales. We can quantify the strength of inter-trial correlations by measuring the decay of the autocorrelation function (ACF), which describes how rapidly information from past trials is "forgotten." Processes whose ACFs decay more slowly exhibit longer-term inter-trial correlations (longer memory processes), while processes whose ACFs decay more rapidly exhibit shorterterm inter-trial correlations (shorter memory processes). Longer-term correlations reflect low-frequency activity, which is more easily

  15. AVLIS Production Plant Project Management Plan

    International Nuclear Information System (INIS)

    1984-01-01

    The AVLIS Production Plant is designated as a Major System Acquisition (in accordance with DOE Order 4240.IC) to deploy Atomic Vapor Laser Isotope Separation (AVLIS) technology at the Oak Ridge, Tennessee site, in support of the US Uranium Enrichment Program. The AVLIS Production Plant Project will deploy AVLIS technology by performing the design, construction, and startup of a production plant that will meet capacity production requirements of the Uranium Enrichment Program. The AVLIS Production Plant Project Management Plan has been developed to outline plans, baselines, and control systems to be employed in managing the AVLIS Production Plant Project and to define the roles and responsibilities of project participants. Participants will develop and maintain detailed procedures for implementing the management and control systems in agreement with this plan. This baseline document defines the system that measures work performed and costs incurred. This plan was developed by the AVLIS Production Plant Project staff of Martin Marietta Energy Systems, Inc. and Lawrence Livermore National Laboratory in accordance with applicable DOE directives, orders and notices. 38 figures, 19 tables

  16. Probing neutrino oscillations jointly in long and very long baseline experiments

    International Nuclear Information System (INIS)

    Wang, Y.F.; Whisnant, K.; Young Binglin; Xiong Zhaohua; Yang Jinmin

    2002-01-01

    We examine the prospects of making a joint analysis of neutrino oscillations at two baselines with neutrino superbeams. Assuming narrow band superbeams and a 100 kiloton water Cherenkov calorimeter, we calculate the event rates and sensitivities to the matter effect, the signs of the neutrino mass differences, the CP phase, and the mixing angle θ 13 . Taking into account all possible experimental errors under general consideration, we explore the optimum cases of a narrow band beam to measure the matter effect and the CP violation effect at all baselines up to 3000 km. We then focus on two specific baselines, a long baseline of 300 km and a very long baseline of 2100 km, and analyze their joint capabilities. We find that the joint analysis can offer extra leverage to resolve some of the ambiguities that are associated with the measurement at a single baseline

  17. A baseline-free procedure for transformation models under interval censorship.

    Science.gov (United States)

    Gu, Ming Gao; Sun, Liuquan; Zuo, Guoxin

    2005-12-01

    An important property of Cox regression model is that the estimation of regression parameters using the partial likelihood procedure does not depend on its baseline survival function. We call such a procedure baseline-free. Using marginal likelihood, we show that an baseline-free procedure can be derived for a class of general transformation models under interval censoring framework. The baseline-free procedure results a simplified and stable computation algorithm for some complicated and important semiparametric models, such as frailty models and heteroscedastic hazard/rank regression models, where the estimation procedures so far available involve estimation of the infinite dimensional baseline function. A detailed computational algorithm using Markov Chain Monte Carlo stochastic approximation is presented. The proposed procedure is demonstrated through extensive simulation studies, showing the validity of asymptotic consistency and normality. We also illustrate the procedure with a real data set from a study of breast cancer. A heuristic argument showing that the score function is a mean zero martingale is provided.

  18. Baseline cerebral oximetry values depend on non-modifiable patient characteristics.

    Science.gov (United States)

    Valencia, Lucía; Rodríguez-Pérez, Aurelio; Ojeda, Nazario; Santana, Romen Yone; Morales, Laura; Padrón, Oto

    2015-12-01

    The aim of the present study was to evaluate baseline regional cerebral oxygen saturation (rSO2) values and identify factors influencing preoperative rSO2 in elective minor surgery. Observational analysis post-hoc. Observational post-hoc analysis of data for the patient sample (n=50) of a previously conducted clinical trial in patients undergoing tumourectomy for breast cancer or inguinal hernia repair. Exclusion criteria included pre-existing cerebrovascular diseases, anaemia, baseline pulse oximetry values were recorded while the patient breathed room air, using the INVOS 5100C monitor™ (Covidien, Dublin, Ireland). Thirty-seven women (72%) and 13 men (28%) 48 ± 13 years of age were enrolled in this study. Baseline rSO2 was 62.01 ± 10.38%. Baseline rSO2 was significantly different between men (67.6 ± 11.2%) and women (60 ± 9.4%), (P=0.023). There were also differences between baseline rSO2 and ASA physical status (ASA I: 67.6 ± 10.7%, ASA II: 61.6 ± 8.4%, ASA III: 55.8 ± 13.9%, P=0.045). Baseline rSO2 had a positive correlation with body weight (r=0.347, P=0.014) and height (r=0.345, P=0.014). We also found significant differences in baseline rSO2 among patients with and without chronic renal failure (P=0.005). No differences were found in any other studied variables. Non-modifiable patient characteristics (ASA physical status, sex, chronic renal failure, body weight and height) influence baseline rSO2. Copyright © 2015 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  19. The California Baseline Methane Survey

    Science.gov (United States)

    Duren, R. M.; Thorpe, A. K.; Hopkins, F. M.; Rafiq, T.; Bue, B. D.; Prasad, K.; Mccubbin, I.; Miller, C. E.

    2017-12-01

    The California Baseline Methane Survey is the first systematic, statewide assessment of methane point source emissions. The objectives are to reduce uncertainty in the state's methane budget and to identify emission mitigation priorities for state and local agencies, utilities and facility owners. The project combines remote sensing of large areas with airborne imaging spectroscopy and spatially resolved bottom-up data sets to detect, quantify and attribute emissions from diverse sectors including agriculture, waste management, oil and gas production and the natural gas supply chain. Phase 1 of the project surveyed nearly 180,000 individual facilities and infrastructure components across California in 2016 - achieving completeness rates ranging from 20% to 100% per emission sector at < 5 meters spatial resolution. Additionally, intensive studies of key areas and sectors were performed to assess source persistence and variability at times scales ranging from minutes to months. Phase 2 of the project continues with additional data collection in Spring and Fall 2017. We describe the survey design and measurement, modeling and analysis methods. We present initial findings regarding the spatial, temporal and sectoral distribution of methane point source emissions in California and their estimated contribution to the state's total methane budget. We provide case-studies and lessons learned about key sectors including examples where super-emitters were identified and mitigated. We summarize challenges and recommendations for future methane research, inventories and mitigation guidance within and beyond California.

  20. Effects of Baseline Selection on Magnetocardiography: P-Q and T-P Intervals

    International Nuclear Information System (INIS)

    Lim, Hyun Kyoon; Kwon, Hyuk Chan; Kim, Tae En; Lee, Yong Ho; Kim, Jin Mok; Kim, In Seon; Kim, Ki Woong; Park, Yong Ki

    2007-01-01

    The baseline selection is the first and important step to analyze magnetocardiography (MCG) parameters. There are no difficulties to select the baseline between P- and Q-wave peak (P-Q interval) of MCG wave recorded from healthy subjects because the P-Q intervals of the healthy subjects do not much vary. However, patients with ischemic heart disease often show an unstable P-Q interval which does not seem to be appropriate for the baseline. In this case, T-P interval is alternatively recommended for the baseline. However, there has been no study on the difference made by the baseline selection. In this study, we studied the effect of the different baseline selection. MCG data were analyzed from twenty healthy subjects and twenty one patients whose baselines were alternatively selected in the T-P interval for their inappropriate P-Q interval. Paired T-test was used to compare two set of data. Fifteen parameters derived from the R-wave peak, the T-wave peak, and the period, T max/3 ∼ T max were compared for the different baseline selection. As a result, most parameters did not show significant differences (p>0.05) except few parameters. Therefore, there will be no significant differences if anyone of two intervals were selected for the MCG baseline. However, for the consistent analysis, P-Q interval is strongly recommended for the baseline correction.

  1. Ultrasonographic differentiation of biliary atresia and neonatal hepatitis: Reestablishment of size criteria of the gallbladder

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woo Sun; Cheon, Jung Eun; Koh, Young Hwan; Kim, In One; Yeon, Kyung Mo [Seoul National University College of Medicine and Institude of Radiation Medicion, Seoul (Korea, Republic of)

    2001-12-15

    To reestablish the size criterion of the gallbladder on ultrasonography (US) for the differentiation diagnosis of biliary atresia from neonatal hepatitis. Abdominal US ws performed in 201 patients with jaundice and 40 patients without evidence of jaundice or hepatobiliary illness (all with the age less than 4 months). US was performed in fasting (fasting for at least 4 hours) to measure the length of the gallbladder and calculated the area of the gallbladder lumen. The morphology of the gallbladder was classified into three types: normal, elongated and atretic. To evaluate the contractibility of the gallbladder, the length of the gallbladder and area of the gallbladder lumen was again measured 1 hour after feeding. The final diagnosis included biliary atresia in 79 patients and neonatal hepatitis in 83 patients. Differences in the length, area, and morphology of the gallbladder were statistically significant among three groups, the normal group, neonatal hepatitis group and biliary atresia group (length and area of gallbladder; normal group>neonatal hepatitis>biliary atresia). The differences in the length and area of gallbladder between pre- and postmeal state were statistically significant in the normal and neonatal hepatitis groups whereas those of biliary atresia were not significant (p=0.85). When the empirical size criterion of the gallbladder (<15 mm in length) was applied, the sensitivity, specificity and diagnostic accuracy for the differential diagnosis of biliary atresia from hepatitis were 52%, 82%, and 67%, respectively. Meanwhile, if the area criterion(<30 mm{sup 2} in area) was applied, the sensitivity, the specificity and diagnostic accuracy were 67%, 85%, and 75%, respectively. Ultrasonographic evaluation of the morphology as well as size of the gallbladder are helpful in the differential diagnosis of biliary atresia from neonatal hepatitis. Therefore, since the measurement of the area of gallbladder lumen on US reflect both size and morphology of

  2. 40 CFR 80.915 - How are the baseline toxics value and baseline toxics volume determined?

    Science.gov (United States)

    2010-07-01

    ... baseline toxics value if it can determine an applicable toxics value for every batch of gasoline produced... of gasoline batch i produced or imported between January 1, 1998 and December 31, 2000, inclusive. i = Individual batch of gasoline produced or imported between January 1, 1998 and December 31, 2000, inclusive. n...

  3. Shifted Baselines Reduce Willingness to Pay for Conservation

    Directory of Open Access Journals (Sweden)

    Loren McClenachan

    2018-02-01

    Full Text Available A loss of memory of past environmental degradation has resulted in shifted baselines, which may result in conservation and restoration goals that are less ambitious than if stakeholders had a full knowledge of ecosystem potential. However, the link between perception of baseline states and support for conservation planning has not been tested empirically. Here, we investigate how perceptions of change in coral reef ecosystems affect stakeholders' willingness to pay (WTP for the establishment of protected areas. Coral reefs are experiencing rapid, global change that is observable by the public, and therefore provide an ideal ecosystem to test links between beliefs about baseline states and willingness to support conservation. Our survey respondents perceived change to coral reef communities across six variables: coral abundance, fish abundance, fish diversity, fish size, sedimentation, and water pollution. Respondants who accurately perceived declines in reef health had significantly higher WTP for protected areas (US $256.80 vs. $102.50 per year, suggesting that shifted baselines may reduce engagement with conservation efforts. If WTP translates to engagement, this suggests that goals for restoration and recovery are likely to be more ambitious if the public is aware of long term change. Therefore, communicating the scope and depth of environmental problems is essential in engaging the public in conservation.

  4. Baseline Projection Data Book: GRI baseline projection of U.S. Energy Supply and Demand to 2010. 1992 Edition. Volume 1 and Volume 2

    International Nuclear Information System (INIS)

    Holtberg, P.D.; Woods, T.J.; Lihn, M.L.; Koklauner, A.K.

    1992-01-01

    The 1992 Baseline Projection Data Book provides backup data in tabular form for the 1992 GRI Baseline Projection of U.S. Energy Supply and Demand to 2010. Summary tables and data for the residential, commercial, industrial, electric utility, and transportation sectors are presented in the volume

  5. Baseline for the cumulants of net-proton distributions at STAR

    International Nuclear Information System (INIS)

    Luo, Xiaofeng; Mohanty, Bedangadas; Xu, Nu

    2014-01-01

    We present a systematic comparison between the recently measured cumulants of the net-proton distributions by STAR for 0–5% central Au + Au collisions at √(s NN )=7.7–200 GeV and two kinds of possible baseline measure, the Poisson and Binomial baselines. These baseline measures are assuming that the proton and anti-proton distributions independently follow Poisson statistics or Binomial statistics. The higher order cumulant net-proton data are observed to deviate from all the baseline measures studied at 19.6 and 27 GeV. We also compare the net-proton with net-baryon fluctuations in UrQMD and AMPT model, and convert the net-proton fluctuations to net-baryon fluctuations in AMPT model by using a set of formula

  6. Parametric estimation of time varying baselines in airborne interferometric SAR

    DEFF Research Database (Denmark)

    Mohr, Johan Jacob; Madsen, Søren Nørvang

    1996-01-01

    A method for estimation of time varying spatial baselines in airborne interferometric synthetic aperture radar (SAR) is described. The range and azimuth distortions between two images acquired with a non-linear baseline are derived. A parametric model of the baseline is then, in a least square...... sense, estimated from image shifts obtained by cross correlation of numerous small patches throughout the image. The method has been applied to airborne EMISAR imagery from the 1995 campaign over the Storstrommen Glacier in North East Greenland conducted by the Danish Center for Remote Sensing. This has...... reduced the baseline uncertainties from several meters to the centimeter level in a 36 km scene. Though developed for airborne SAR the method can easily be adopted to satellite data...

  7. Baseline Caesium-137 and Plutonium-239+240 inventory assessment for Central Europe

    Science.gov (United States)

    Meusburger, Katrin; Borelli, Pasquale; Evrard, Olivier; Ketterer, Michael; Mabit, Lionel; van Oost, Kristof; Alewell, Christine; Panagos, Panos

    2017-04-01

    Artificial fallout radionuclides (FRNs) such as Caesium-137 and Plutonium-239+240 released as products of the thermonuclear weapons testing that took place from the mid-1950s to the early 1980s and from nuclear power plant accidents (e.g. Chernobyl) are useful tools to quantify soil redistribution. In combination with geostatistics, FRNs may have the potential to bridge the gap between small scale process oriented studies and modelling that simplifies processes and effects over large spatial scales. An essential requirement for the application of FRNs as soil erosion tracers is the establishment of the baseline fallout at undisturbed sites before its comparison to those inventories found at sites undergoing erosion/accumulation. For this purpose, undisturbed topsoil (0-20cm) samples collected in 2009 within the framework of the Land Use/Cover Area frame Survey (LUCAS) have been measured by gamma-spectrometry and ICP-MS to determine 137Cs (n=145) and 239+240Pu (n=108) activities. To restrict the analysis to undisturbed reference sites a geospatial database query selecting only sites having a slope angle <2 degree, outside riparian zones (to avoid depositional sites) and under permanent grassland cover (according to CORINE Land Cover and Landsat) was applied. This study reports preliminary results on the feasibility of establishing a 137Cs and 239+240Pu baseline inventory map for Central Europe. The 137Cs/239+240Pu activity ratios will further allow assessing the rate and the spatial variability of 137Cs Chernobyl fallout. The establishment of such baseline inventory map will provide a unique opportunity to assess soil redistribution for a comparable time-frame (1953-2009) following a harmonised methodological protocol across national boundaries.

  8. The Effect of Pretest Exercise on Baseline Computerized Neurocognitive Test Scores.

    Science.gov (United States)

    Pawlukiewicz, Alec; Yengo-Kahn, Aaron M; Solomon, Gary

    2017-10-01

    Baseline neurocognitive assessment plays a critical role in return-to-play decision making following sport-related concussions. Prior studies have assessed the effect of a variety of modifying factors on neurocognitive baseline test scores. However, relatively little investigation has been conducted regarding the effect of pretest exercise on baseline testing. The aim of our investigation was to determine the effect of pretest exercise on baseline Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores in adolescent and young adult athletes. We hypothesized that athletes undergoing self-reported strenuous exercise within 3 hours of baseline testing would perform more poorly on neurocognitive metrics and would report a greater number of symptoms than those who had not completed such exercise. Cross-sectional study; Level of evidence, 3. The ImPACT records of 18,245 adolescent and young adult athletes were retrospectively analyzed. After application of inclusion and exclusion criteria, participants were dichotomized into groups based on a positive (n = 664) or negative (n = 6609) self-reported history of strenuous exercise within 3 hours of the baseline test. Participants with a positive history of exercise were then randomly matched, based on age, sex, education level, concussion history, and hours of sleep prior to testing, on a 1:2 basis with individuals who had reported no pretest exercise. The baseline ImPACT composite scores of the 2 groups were then compared. Significant differences were observed for the ImPACT composite scores of verbal memory, visual memory, reaction time, and impulse control as well as for the total symptom score. No significant between-group difference was detected for the visual motor composite score. Furthermore, pretest exercise was associated with a significant increase in the overall frequency of invalid test results. Our results suggest a statistically significant difference in ImPACT composite scores between

  9. FED baseline engineering studies report

    Energy Technology Data Exchange (ETDEWEB)

    Sager, P.H.

    1983-04-01

    Studies were carried out on the FED Baseline to improve design definition, establish feasibility, and reduce cost. Emphasis was placed on cost reduction, but significant feasibility concerns existed in several areas, and better design definition was required to establish feasibility and provide a better basis for cost estimates. Design definition and feasibility studies included the development of a labyrinth shield ring concept to prevent radiation streaming between the torus spool and the TF coil cryostat. The labyrinth shield concept which was developed reduced radiation streaming sufficiently to permit contact maintenance of the inboard EF coils. Various concepts of preventing arcing between adjacent shield sectors were also explored. It was concluded that installation of copper straps with molybdenum thermal radiation shields would provide the most reliable means of preventing arcing. Other design studies included torus spool electrical/structural concepts, test module shielding, torus seismic response, poloidal conditions in the magnets, disruption characteristics, and eddy current effects. These additional studies had no significant impact on cost but did confirm the feasibility of the basic FED Baseline concept.

  10. FED baseline engineering studies report

    International Nuclear Information System (INIS)

    Sager, P.H.

    1983-04-01

    Studies were carried out on the FED Baseline to improve design definition, establish feasibility, and reduce cost. Emphasis was placed on cost reduction, but significant feasibility concerns existed in several areas, and better design definition was required to establish feasibility and provide a better basis for cost estimates. Design definition and feasibility studies included the development of a labyrinth shield ring concept to prevent radiation streaming between the torus spool and the TF coil cryostat. The labyrinth shield concept which was developed reduced radiation streaming sufficiently to permit contact maintenance of the inboard EF coils. Various concepts of preventing arcing between adjacent shield sectors were also explored. It was concluded that installation of copper straps with molybdenum thermal radiation shields would provide the most reliable means of preventing arcing. Other design studies included torus spool electrical/structural concepts, test module shielding, torus seismic response, poloidal conditions in the magnets, disruption characteristics, and eddy current effects. These additional studies had no significant impact on cost but did confirm the feasibility of the basic FED Baseline concept

  11. Baseline development, economic risk, and schedule risk: An integrated approach

    International Nuclear Information System (INIS)

    Tonkinson, J.A.

    1994-01-01

    The economic and schedule risks of Environmental Restoration (ER) projects are commonly analyzed toward the end of the baseline development process. Risk analysis is usually performed as the final element of the scheduling or estimating processes for the purpose of establishing cost and schedule contingency. However, there is an opportunity for earlier assessment of risks, during development of the technical scope and Work Breakdown Structure (WBS). Integrating the processes of risk management and baselining provides for early incorporation of feedback regarding schedule and cost risk into the proposed scope of work. Much of the information necessary to perform risk analysis becomes available during development of the technical baseline, as the scope of work and WBS are being defined. The analysis of risk can actually be initiated early on during development of the technical baseline and continue throughout development of the complete project baseline. Indeed, best business practices suggest that information crucial to the success of a project be analyzed and incorporated into project planning as soon as it is available and usable

  12. Cysteamine re-establishes the clearance of Pseudomonas aeruginosa by macrophages bearing the cystic fibrosis-relevant F508del-CFTR mutation.

    Science.gov (United States)

    Ferrari, Eleonora; Monzani, Romina; Villella, Valeria R; Esposito, Speranza; Saluzzo, Francesca; Rossin, Federica; D'Eletto, Manuela; Tosco, Antonella; De Gregorio, Fabiola; Izzo, Valentina; Maiuri, Maria C; Kroemer, Guido; Raia, Valeria; Maiuri, Luigi

    2017-01-12

    Cystic fibrosis (CF), the most common lethal monogenic disease in Caucasians, is characterized by recurrent bacterial infections and colonization, mainly by Pseudomonas aeruginosa, resulting in unresolved airway inflammation. CF is caused by mutations in the gene coding for the cystic fibrosis transmembrane conductance regulator (CFTR) protein, which functions as a chloride channel in epithelial cells, macrophages, and other cell types. Impaired bacterial handling by macrophages is a feature of CF airways, although it is still debated how defective CFTR impairs bacterial killing. Recent evidence indicates that a defective autophagy in CF macrophages leads to alterations of bacterial clearance upon infection. Here we use bone marrow-derived macrophages from transgenic mice to provide the genetic proof that defective CFTR compromises both uptake and clearance of internalized Pseudomonas aeruginosa. We demonstrate that the proteostasis regulator cysteamine, which rescues the function of the most common F508del-CFTR mutant and hence reduces lung inflammation in CF patients, can also repair the defects of CF macrophages, thus restoring both bacterial internalization and clearance through a process that involves upregulation of the pro-autophagic protein Beclin 1 and re-establishment of the autophagic pathway. Altogether these results indicate that cysteamine restores the function of several distinct cell types, including that of macrophages, which might contribute to its beneficial effects on CF.

  13. Baseline measures for net-proton distributions in high energy heavy-ion collisions

    International Nuclear Information System (INIS)

    Netrakanti, P.K.; Mishra, D.K.; Mohanty, A.K.; Mohanty, B.

    2014-01-01

    The STAR experiment at the Relativistic Heavy-Ion Collider facility has reported results for the cumulants and their ratios from the net-proton distributions upto the fourth order cumulants at various collision energies. These measurements were carried to look for the signatures of the possible critical point (CP) in the phase diagram for a system undertaking strong interactions. The results show an intriguing dependence of the cumulant ratios C 3 /C 2 and C 4 /C 2 as a function of beam energy. The beam energy dependence appears to be non-monotonic in nature. However the experiment also reports that the energy dependence is observed to be consistent with expectation from an approach based on the independent production of proton and anti-protons in the collisions. In this paper we emphasize the need to have a proper baseline for appropriate interpretation of the cumulant measurements and argue that the comparison to independent production approach needs to be done with extreme caution

  14. Performance Analysis for Airborne Interferometric SAR Affected by Flexible Baseline Oscillation

    Directory of Open Access Journals (Sweden)

    Liu Zhong-sheng

    2014-04-01

    Full Text Available The airborne interferometric SAR platform suffers from instability factors, such as air turbulence and mechanical vibrations during flight. Such factors cause the oscillation of the flexible baseline, which leads to significant degradation of the performance of the interferometric SAR system. This study is concerned with the baseline oscillation. First, the error of the slant range model under baseline oscillation conditions is formulated. Then, the SAR complex image signal and dual-channel correlation coefficient are modeled based on the first-order, second-order, and generic slant range error. Subsequently, the impact of the baseline oscillation on the imaging and interferometric performance of the SAR system is analyzed. Finally, simulations of the echo data are used to validate the theoretical analysis of the baseline oscillation in the airborne interferometric SAR.

  15. Production of effective microorganism using halal- based sources: A ...

    African Journals Online (AJOL)

    GREGORY

    2011-12-16

    Dec 16, 2011 ... ... and Devkota (2009) also reveal- ed that pesticide residues had contaminated soil in the. *Corresponding .... EM technology involves growing, applying, managing and re-establishing high populations of ... world is the treatment, disposal and/or recycling of solid wastes. Solutions using EM developed in ...

  16. Influence of Baseline Psychological Health on Muscle Pain During Atorvastatin Treatment.

    Science.gov (United States)

    Zaleski, Amanda L; Taylor, Beth A; Pescatello, Linda S; Dornelas, Ellen A; White, Charles Michael; Thompson, Paul D

    3-hydroxy-3-methylglutaryl coenzyme A reductase reductase inhibitors (statins) are generally well tolerated, with statin-associated muscle symptoms (SAMS) the most common side effect (~10%) seen in statin users. However, studies and clinical observations indicate that many of the self-reported SAMS appear to be nonspecific (ie, potentially not attributable to statins). Mental health and well-being influence self-perception of pain, so we sought to assess the effect of baseline well-being and depression on the development of muscle pain with 6 months of atorvastatin 80 mg/d (ATORVA) or placebo in healthy, statin-naive adults. The Psychological General Well-being Index (n = 83) and Beck Depression Inventory (n = 55) questionnaires were administered at baseline in participants (aged 59.5 ± 1.2 years) from the effect of Statins on Skeletal Muscle Function and Performance (STOMP) trial (NCT00609063). Muscle pain (Short-Form McGill Pain Questionnaire [SF-MPQ]), pain that interferes with daily life (Brief Pain Inventory [BPI]), and pain severity (BPI) were then measured before, throughout, and after treatment. At baseline, there were no differences in well-being (Psychological General Well-being Index), depression (Beck Depression Inventory), or pain measures (SF-MPQ and BPI) (P values ≥ .05) between the placebo and ATORVA groups. Baseline well-being correlated negatively with baseline BPI pain severity (r = -0.290, P = .008). Baseline depression correlated with baseline pain (SF-MPQ; r = 0.314, P = .020). Baseline well-being and depression did not predict the change in pain severity or interference after 6 months among the total sample or between groups (P values ≥ .05). Baseline well-being and depression were not significant predictors of pain after 6 months of ATORVA (P values ≥ .05). Thus, they do not appear to increase the risk of SAMS in otherwise healthy adults.

  17. Baseline Report on HB2320

    Science.gov (United States)

    State Council of Higher Education for Virginia, 2015

    2015-01-01

    Staff provides this baseline report as a summary of its preliminary considerations and initial research in fulfillment of the requirements of HB2320 from the 2015 session of the General Assembly. Codified as § 23-7.4:7, this legislation compels the Education Secretary and the State Council of Higher Education for Virginia (SCHEV) Director, in…

  18. Can “Ethical Traceability” re-establish the producer-consumer relation?

    DEFF Research Database (Denmark)

    in the processes. All of these factors add to the obscurity of how food is produced, how it is handled and from where it originates. Traceability is about keeping track with the history of the food. Ethical traceability is about keeping track with the ethical aspects of food production practices and the conditions...... of private sector and public sector endorsed traceability forms in the food system. Realisation of ethical traceability is not just a morally approved step supported by appropriate technology and communication strategies, but is a politically disputed process. The aim here is to focus on the communication...... of production practices in the food chain. In this sense, traceability is about visibility, it is about making the production history of food visible to the eyes of the consumers. In this way traceability allows for producers and retailers to establish a more advanced kind of communication with consumers...

  19. Pediatric Heart Transplantation: Transitioning to Adult Care (TRANSIT): Baseline Findings.

    Science.gov (United States)

    Grady, Kathleen L; Hof, Kathleen Van't; Andrei, Adin-Cristian; Shankel, Tamara; Chinnock, Richard; Miyamoto, Shelley; Ambardekar, Amrut V; Anderson, Allen; Addonizio, Linda; Latif, Farhana; Lefkowitz, Debra; Goldberg, Lee; Hollander, Seth A; Pham, Michael; Weissberg-Benchell, Jill; Cool, Nichole; Yancy, Clyde; Pahl, Elfriede

    2018-02-01

    Young adult solid organ transplant recipients who transfer from pediatric to adult care experience poor outcomes related to decreased adherence to the medical regimen. Our pilot trial for young adults who had heart transplant (HT) who transfer to adult care tests an intervention focused on increasing HT knowledge, self-management and self-advocacy skills, and enhancing support, as compared to usual care. We report baseline findings between groups regarding (1) patient-level outcomes and (2) components of the intervention. From 3/14 to 9/16, 88 subjects enrolled and randomized to intervention (n = 43) or usual care (n = 45) at six pediatric HT centers. Patient self-report questionnaires and medical records data were collected at baseline, and 3 and 6 months after transfer. For this report, baseline findings (at enrollment and prior to transfer to adult care) were analyzed using Chi-square and t-tests. Level of significance was p Baseline demographics were similar in the intervention and usual care arms: age 21.3 ± 3.2 vs 21.5 ± 3.3 years and female 44% vs 49%, respectively. At baseline, there were no differences between intervention and usual care for use of tacrolimus (70 vs 62%); tacrolimus level (mean ± SD = 6.5 ± 2.3 ng/ml vs 5.6 ± 2.3 ng/ml); average of the within patient standard deviation of the baseline mean tacrolimus levels (1.6 vs 1.3); and adherence to the medical regimen [3.6 ± 0.4 vs 3.5 ± 0.5 (1 = hardly ever to 4 = all of the time)], respectively. At baseline, both groups had a modest amount of HT knowledge, were learning self-management and self-advocacy, and perceived they were adequately supported. Baseline findings indicate that transitioning HT recipients lack essential knowledge about HT and have incomplete self-management and self-advocacy skills.

  20. Baseline estradiol concentration in community-dwelling Japanese American men is not associated with intra-abdominal fat accumulation over 10 years.

    Science.gov (United States)

    Kocarnik, Beverly M; Boyko, Edward J; Matsumoto, Alvin M; Fujimoto, Wilfred Y; Hayashi, Tomoshige; Leonetti, Donna L; Page, Stephanie T

    The role of plasma estradiol in the accumulation of intra-abdominal fat (IAF) in men is uncertain. Cross-sectional studies using imaging of IAF have shown either a positive or no association. In contrast, a randomised controlled trial using an aromatase inhibitor to suppress estradiol production found an association between oestrogen deficiency and short-term IAF accumulation. No longitudinal study has been conducted to examine the relationship between plasma estradiol concentration and the change in IAF area measured using direct imaging. This is a longitudinal observational study in community-dwelling Japanese-American men (n=215, mean age 52 years, BMI 25.4kg/m 2 ). IAF and subcutaneous fat areas were assessed using computerized tomography (CT) at baseline, 5 and 10 years. Baseline plasma estradiol concentrations were measured using liquid chromatography-tandem mass spectrometry. Univariate analysis found no association between baseline estradiol concentration and baseline IAF, or 5- or 10-year changes in IAF area (r=-0.05 for both time points, p=0.45 and p=0.43, respectively). Multivariate linear regression analysis of the change in IAF area by baseline estradiol concentration adjusted for age, baseline IAF area, and weight change found no association with either the 5- or 10-year IAF area change (p=0.52 and p=0.55, respectively). Plasma estradiol concentration was not associated with baseline IAF nor with change in IAF area over 5 or 10 years based on serial CT scans in community-dwelling Japanese-American men. These results do not support a role for oestrogen deficiency in IAF accumulation in men. Copyright © 2015 Asia Oceania Association for the Study of Obesity. All rights reserved.

  1. The Baselines Project: Establishing Reference Environmental Conditions for Marine Habitats in the Gulf of Mexico using Forecast Models and Satellite Data

    Science.gov (United States)

    Jolliff, J. K.; Gould, R. W.; deRada, S.; Teague, W. J.; Wijesekera, H. W.

    2012-12-01

    We provide an overview of the NASA-funded project, "High-Resolution Subsurface Physical and Optical Property Fields in the Gulf of Mexico: Establishing Baselines and Assessment Tools for Resource Managers." Data assimilative models, analysis fields, and multiple satellite data streams were used to construct temperature and photon flux climatologies for the Flower Garden Banks National Marine Sanctuary (FGBNMS) and similar habitats in the northwestern Gulf of Mexico where geologic features provide a platform for unique coral reef ecosystems. Comparison metrics of the products to in situ data collected during complimentary projects are also examined. Similarly, high-resolution satellite-data streams and advanced processing techniques were used to establish baseline suspended sediment load and turbidity conditions in selected northern Gulf of Mexico estuaries. The results demonstrate the feasibility of blending models and data into accessible web-based analysis products for resource managers, policy makers, and the public.

  2. Baselining the New GSFC Information Systems Center: The Foundation for Verifiable Software Process Improvement

    Science.gov (United States)

    Parra, A.; Schultz, D.; Boger, J.; Condon, S.; Webby, R.; Morisio, M.; Yakimovich, D.; Carver, J.; Stark, M.; Basili, V.; hide

    1999-01-01

    This paper describes a study performed at the Information System Center (ISC) in NASA Goddard Space Flight Center. The ISC was set up in 1998 as a core competence center in information technology. The study aims at characterizing people, processes and products of the new center, to provide a basis for proposing improvement actions and comparing the center before and after these actions have been performed. The paper presents the ISC, goals and methods of the study, results and suggestions for improvement, through the branch-level portion of this baselining effort.

  3. Baseline Optimization for the Measurement of CP Violation, Mass Hierarchy, and $\\theta_{23}$ Octant in a Long-Baseline Neutrino Oscillation Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Bass, M. [Colorado State U.; Bishai, M. [Brookhaven; Cherdack, D. [Colorado State U.; Diwan, M. [Brookhaven; Djurcic, Z. [Argonne; Hernandez, J. [Houston U.; Lundberg, B. [Fermilab; Paolone, V. [Pittsburgh U.; Qian, X. [Brookhaven; Rameika, R. [Fermilab; Whitehead, L. [Houston U.; Wilson, R. J. [Colorado State U.; Worcester, E. [Brookhaven; Zeller, G. [Fermilab

    2015-03-19

    Next-generation long-baseline electron neutrino appearance experiments will seek to discover CP violation, determine the mass hierarchy and resolve the θ23 octant. In light of the recent precision measurements of θ13, we consider the sensitivity of these measurements in a study to determine the optimal baseline, including practical considerations regarding beam and detector performance. We conclude that a detector at a baseline of at least 1000 km in a wide-band muon neutrino beam is the optimal configuration.

  4. Should Studies of Diabetes Treatment Stratification Correct for Baseline HbA1c?

    Science.gov (United States)

    Jones, Angus G.; Lonergan, Mike; Henley, William E.; Pearson, Ewan R.; Hattersley, Andrew T.; Shields, Beverley M.

    2016-01-01

    Aims Baseline HbA1c is a major predictor of response to glucose lowering therapy and therefore a potential confounder in studies aiming to identify other predictors. However, baseline adjustment may introduce error if the association between baseline HbA1c and response is substantially due to measurement error and regression to the mean. We aimed to determine whether studies of predictors of response should adjust for baseline HbA1c. Methods We assessed the relationship between baseline HbA1c and glycaemic response in 257 participants treated with GLP-1R agonists and assessed whether it reflected measurement error and regression to the mean using duplicate ‘pre-baseline’ HbA1c measurements not included in the response variable. In this cohort and an additional 2659 participants treated with sulfonylureas we assessed the relationship between covariates associated with baseline HbA1c and treatment response with and without baseline adjustment, and with a bias correction using pre-baseline HbA1c to adjust for the effects of error in baseline HbA1c. Results Baseline HbA1c was a major predictor of response (R2 = 0.19,β = -0.44,pHbA1c were associated with response, however these associations were weak or absent after adjustment for baseline HbA1c. Bias correction did not substantially alter associations. Conclusions Adjustment for the baseline HbA1c measurement is a simple and effective way to reduce bias in studies of predictors of response to glucose lowering therapy. PMID:27050911

  5. Motivation Enhancement Therapy with pregnant substance-abusing women: does baseline motivation moderate efficacy?

    Science.gov (United States)

    Ondersma, Steven J; Winhusen, Theresa; Erickson, Sarah J; Stine, Susan M; Wang, Yun

    2009-04-01

    Some evidence suggests that motivational approaches are less efficacious--or even counter-productive--with persons who are relatively motivated at baseline. The present study was conducted to examine whether disordinal moderation by baseline motivation could partially explain negative findings in a previous study [Winhusen, T., Kropp, F., Babcock, D., Hague, D., Erickson, S.J., Renz, C., Rau, L., Lewis, D., Leimberger, J., Somoza, E., 2008. Motivational enhancement therapy to improve treatment utilization and outcome in pregnant substance users. J. Subst. Abuse Treat. 35, 161-173]. Analyses also focused on the relative utility of the University of Rhode Island Change Assessment (URICA) scale, vs. a single goal question as potential moderators of Motivation Enhancement Therapy (MET). Participants were 200 pregnant women presenting for substance abuse treatment at one of four sites. Women were randomly assigned to either a three-session MET condition or treatment as usual (TAU). Generalized Estimating Equations (GEE) revealed no significant moderation effects on drug use at post-treatment. At follow-up, contrary to expectations, participants who had not set a clear quit goal at baseline were less likely to be drug-free if randomized to MET (OR=0.48); participants who did set a clear quit goal were more likely to be drug-free if randomized to MET (OR=2.53). No moderating effects were identified via the URICA. Disordinal moderation of MET efficacy by baseline motivation may have contributed somewhat to the negative results of the [Winhusen, T., Kropp, F., Babcock, D., Hague, D., Erickson, S.J., Renz, C., Rau, L., Lewis, D., Leimberger, J., Somoza, E., 2008. Motivational enhancement therapy to improve treatment utilization and outcome in pregnant substance users. J. Subst. Abuse Treat. 35, 161-173] study, but in the opposite direction expected. A simple question regarding intent to quit may be useful in identifying persons who may differentially respond to motivational

  6. Fiscal year 1996 U.S. Department of Energy, Richland Operations Office Site summary baseline

    International Nuclear Information System (INIS)

    Johndro-Collins, A.

    1995-10-01

    The technical baseline is a hierarchical description of the Hanford Site cleanup mission. This technical baseline does not address the science, technology, or economic transition missions. It begins with a definition of the existing conditions at the Hanford Site, provides a description of the end product or mission accomplishments at completion, presents a statement of the major requirements and constraints that must be observed during the performance of the mission, and provides a statement of the top-level strategic approach to accomplish the mission. Mission-level interfaces are also described. This information is further defined hierarchically in increasing levels of detail. This definition is composed of the following major elements: functions that are key task descriptions; requirements that are the measurable standards to which the functions must be performed; architectures which are specific engineering solutions or systems that perform the functions described earlier; and verification ensuring the system satisfies the requirements and fulfills the functions. The above information is supplemented with the following: interface data; risk analyses and watch lists; assumptions; and required analyses

  7. Baseline series fragrance markers fail to predict contact allergy.

    Science.gov (United States)

    Mann, Jack; McFadden, John P; White, Jonathan M L; White, Ian R; Banerjee, Piu

    2014-05-01

    Negative patch test results with fragrance allergy markers in the European baseline series do not always predict a negative reaction to individual fragrance substances. To determine the frequencies of positive test reactions to the 26 fragrance substances for which labelling is mandatory in the EU, and how effectively reactions to fragrance markers in the baseline series predict positive reactions to the fragrance substances that are labelled. The records of 1951 eczema patients, routinely tested with the labelled fragrance substances and with an extended European baseline series in 2011 and 2012, were retrospectively reviewed. Two hundred and eighty-one (14.4%) (71.2% females) reacted to one or more allergens from the labelled-fragrance substance series and/or a fragrance marker from the European baseline series. The allergens that were positive with the greatest frequencies were cinnamyl alcohol (48; 2.46%), Evernia furfuracea (44; 2.26%), and isoeugenol (40; 2.05%). Of the 203 patients who reacted to any of the 26 fragrances in the labelled-fragrance substance series, only 117 (57.6%) also reacted to a fragrance marker in the baseline series. One hundred and seven (52.7%) reacted to either fragrance mix I or fragrance mix II, 28 (13.8%) reacted to Myroxylon pereirae, and 13 (6.4%) reacted to hydroxyisohexyl 3-cyclohexene carboxaldehyde. These findings confirm that the standard fragrance markers fail to identify patients with contact allergies to the 26 fragrances. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Process industry energy retrofits: the importance of emission baselines for greenhouse gas reductions

    International Nuclear Information System (INIS)

    Aadahl, Anders; Harvey, Simon; Berntsson, Thore

    2004-01-01

    Fuel combustion for heat and/or electric power production is often the largest contributor of greenhouse gas (GHG) emissions from an industrial process plant. Economically feasible options to reduce these emissions include fuel switching and retrofitting the plant's energy system. Process integration methods and tools can be used to evaluate potential retrofit measures. For assessing the GHG emissions reduction potential for the measures considered, it is also necessary to define appropriate GHG emission baselines. This paper presents a systematic GHG emission calculation method for retrofit situations including improved heat exchange, integration of combined heat and power (CHP) units, and combinations of both. The proposed method is applied to five different industrial processes in order to compare the impact of process specific parameters and energy market specific parameters. For potential GHG emission reductions the results from the applied study reveal that electricity grid emissions are significantly more important than differences between individual processes. Based on the results of the study, it is suggested that for sustainable investment decision considerations a conservative emission baseline is most appropriate. Even so, new industrial CHP in the Northern European energy market could play a significant role in the common effort to decrease GHG emissions

  9. A publication database for optical long baseline interferometry

    Science.gov (United States)

    Malbet, Fabien; Mella, Guillaume; Lawson, Peter; Taillifet, Esther; Lafrasse, Sylvain

    2010-07-01

    Optical long baseline interferometry is a technique that has generated almost 850 refereed papers to date. The targets span a large variety of objects from planetary systems to extragalactic studies and all branches of stellar physics. We have created a database hosted by the JMMC and connected to the Optical Long Baseline Interferometry Newsletter (OLBIN) web site using MySQL and a collection of XML or PHP scripts in order to store and classify these publications. Each entry is defined by its ADS bibcode, includes basic ADS informations and metadata. The metadata are specified by tags sorted in categories: interferometric facilities, instrumentation, wavelength of operation, spectral resolution, type of measurement, target type, and paper category, for example. The whole OLBIN publication list has been processed and we present how the database is organized and can be accessed. We use this tool to generate statistical plots of interest for the community in optical long baseline interferometry.

  10. The steps to health employee weight management randomized control trial: rationale, design and baseline characteristics.

    Science.gov (United States)

    Østbye, Truls; Stroo, Marissa; Brouwer, Rebecca J N; Peterson, Bercedis L; Eisenstein, Eric L; Fuemmeler, Bernard F; Joyner, Julie; Gulley, Libby; Dement, John M

    2013-07-01

    The workplace can be an important setting for addressing obesity. An increasing number of employers offer weight management programs. Present the design, rationale and baseline characteristics of the Steps to Health study (STH), a randomized trial to evaluate the effectiveness of two preexisting employee weight management programs offered at Duke University and Medical Center. 550 obese (BMI ≥30) employee volunteers were randomized 1:1 to two programs. Baseline data, collected between January 2011 and July 2012, included height/weight, accelerometry, workplace injuries, health care utilization, and questionnaires querying socio-cognitive factors, perceptions of health climate, physical activity, and dietary intake. In secondary analyses participants in the two programs will also be compared to a non-randomized observational control group of obese employees. At baseline, the mean age was 45 years, 83% were female, 41% white, and 53% black. Mean BMI was 37.2. Participants consumed a mean of 2.37 servings of fruits and vegetables per day (in the past week), participated in 11.5 min of moderate-to-vigorous physical activity, and spent 620 min being sedentary. STH addresses the need for evaluation of worksite interventions to promote healthy weight. In addition to having direct positive effects on workers' health, worksite programs have the potential to increase productivity and reduce health care costs. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Back-calculating baseline creatinine overestimates prevalence of acute kidney injury with poor sensitivity.

    Science.gov (United States)

    Kork, F; Balzer, F; Krannich, A; Bernardi, M H; Eltzschig, H K; Jankowski, J; Spies, C

    2017-03-01

    Acute kidney injury (AKI) is diagnosed by a 50% increase in creatinine. For patients without a baseline creatinine measurement, guidelines suggest estimating baseline creatinine by back-calculation. The aim of this study was to evaluate different glomerular filtration rate (GFR) equations and different GFR assumptions for back-calculating baseline creatinine as well as the effect on the diagnosis of AKI. The Modification of Diet in Renal Disease, the Chronic Kidney Disease Epidemiology (CKD-EPI) and the Mayo quadratic (MQ) equation were evaluated to estimate baseline creatinine, each under the assumption of either a fixed GFR of 75 mL min -1  1.73 m -2 or an age-adjusted GFR. Estimated baseline creatinine, diagnoses and severity stages of AKI based on estimated baseline creatinine were compared to measured baseline creatinine and corresponding diagnoses and severity stages of AKI. The data of 34 690 surgical patients were analysed. Estimating baseline creatinine overestimated baseline creatinine. Diagnosing AKI based on estimated baseline creatinine had only substantial agreement with AKI diagnoses based on measured baseline creatinine [Cohen's κ ranging from 0.66 (95% CI 0.65-0.68) to 0.77 (95% CI 0.76-0.79)] and overestimated AKI prevalence with fair sensitivity [ranging from 74.3% (95% CI 72.3-76.2) to 90.1% (95% CI 88.6-92.1)]. Staging AKI severity based on estimated baseline creatinine had moderate agreement with AKI severity based on measured baseline creatinine [Cohen's κ ranging from 0.43 (95% CI 0.42-0.44) to 0.53 (95% CI 0.51-0.55)]. Diagnosing AKI and staging AKI severity on the basis of estimated baseline creatinine in surgical patients is not feasible. Patients at risk for post-operative AKI should have a pre-operative creatinine measurement to adequately assess post-operative AKI. © 2016 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  12. Electricity End Uses, Energy Efficiency, and Distributed Energy Resources Baseline

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, Lisa [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wei, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Morrow, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Deason, Jeff [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schiller, Steven R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Leventis, Greg [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Smith, Sarah [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Leow, Woei Ling [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Levin, Todd [Argonne National Lab. (ANL), Argonne, IL (United States); Plotkin, Steven [Argonne National Lab. (ANL), Argonne, IL (United States); Zhou, Yan [Oak Ridge Inst. for Science and Education (ORISE), Oak Ridge, TN (United States)

    2017-01-01

    This report was developed by a team of analysts at Lawrence Berkeley National Laboratory, with Argonne National Laboratory contributing the transportation section, and is a DOE EPSA product and part of a series of “baseline” reports intended to inform the second installment of the Quadrennial Energy Review (QER 1.2). QER 1.2 provides a comprehensive review of the nation’s electricity system and cover the current state and key trends related to the electricity system, including generation, transmission, distribution, grid operations and planning, and end use. The baseline reports provide an overview of elements of the electricity system. This report focuses on end uses, electricity consumption, electric energy efficiency, distributed energy resources (DERs) (such as demand response, distributed generation, and distributed storage), and evaluation, measurement, and verification (EM&V) methods for energy efficiency and DERs.

  13. The ecosystem baseline for particle flux in the Northern Gulf of Mexico

    Directory of Open Access Journals (Sweden)

    S.L.C. Giering

    2018-01-01

    Full Text Available Response management and damage assessment during and after environmental disasters such as the Deepwater Horizon (DWH oil spill require an ecological baseline and a solid understanding of the main drivers of the ecosystem. During the DWH event, a large fraction of the spilled oil was transported to depth via sinking marine snow, a routing of spilled oil unexpected to emergency response planners. Because baseline knowledge of particle export in the Northern Gulf of Mexico and how it varies spatially and temporally was limited, we conducted a detailed assessment of the potential drivers of deep (~1400 m depth particle fluxes during 2012–2016 using sediment traps at three contrasting sites in the Northern Gulf of Mexico: near the DWH site, at an active natural oil seep site, and at a site considered typical for background conditions. The DWH site, located ~70 km from the Mississippi River Delta, showed flux patterns that were strongly linked to the Mississippi nitrogen discharge and an annual subsequent surface bloom. Fluxes carried clear signals of combustion products, which likely originated from pyrogenic sources that were transported offshore via the Mississippi plume. The seep and reference sites were more strongly influenced by the open Gulf of Mexico, did not show a clear seasonal flux pattern, and their overall sedimentation rates were lower than those at the DWH site. At the seep site, based on polycyclic aromatic hydrocarbon data, we observed indications of three different pathways for “natural” oiled-snow sedimentation: scavenging by sinking particles at depth, weathering at the surface before incorporation into sinking particles, and entry into the food web and subsequent sinking in form of detritus. Overall, sedimentation rates at the three sites were markedly different in quality and quantity owing to varying degrees of riverine and oceanic influences, including natural seepage and contamination by combustion products.

  14. Wind power projects in the CDM: Methodologies and tools for baselines, carbon financing and substainability analysis[CDM=Clean Development Mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Ringius, L.; Grohnheit, P.E.; Nielsen, L.H.; Olivier, A.L.; Painuly, J.; Villavicencio, A.

    2002-12-01

    power production profile of Zafarana, the emission rates estimated by runs with 1 hour time-steps of the simulation tool ES3 range from 0.590 tCO{sub 2}/MWh to 0.610 tCO{sub 2}/MWh. These results come very close to estimates based on two different interpretations of standardized baseline options above. (au)

  15. Solid Waste Program technical baseline description

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, A.B.

    1994-07-01

    The system engineering approach has been taken to describe the technical baseline under which the Solid Waste Program is currently operating. The document contains a mission analysis, function analysis, system definition, documentation requirements, facility and project bases, and uncertainties facing the program.

  16. Geodesy by radio interferometry - Determinations of baseline vector, earth rotation, and solid earth tide parameters with the Mark I very long baseline radio interferometery system

    Science.gov (United States)

    Ryan, J. W.; Clark, T. A.; Coates, R. J.; Ma, C.; Wildes, W. T.

    1986-01-01

    Thirty-seven very long baseline radio interferometry experiments performed between 1972 and 1978 are analyzed and estimates of baseline vectors between six sites, five in the continental United States and one in Europe are derived. No evidence of significant changes in baseline length is found. For example, with a statistical level of confidence of approximately 85 percent, upper bounds on such changes within the United States ranged from a low of 10 mm/yr for the 850 km baseline between Westford, Massachusetts, and Green Bank, West Virginia, to a high of 90 mm/yr for the nearly 4000 km baseline between Westford and Goldstone, California. Estimates for universal time and for the x component of the position of the earth's pole are obtained. For the last 15 experiments, the only ones employing wideband receivers, the root-mean-square differences between the derived values and the corresponding ones published by the Bureau International de l'Heure are 0.0012 s and 0.018 arc sec respectively. The average value obtained for the radial Love number for the solid earth is 0.62 + or - 0.02 (estimated standard error).

  17. Long-baseline neutrino oscillation experiments

    International Nuclear Information System (INIS)

    Crane, D.; Goodman, M.

    1994-01-01

    There is no unambiguous definition for long baseline neutrino oscillation experiments. The term is generally used for accelerator neutrino oscillation experiments which are sensitive to Δm 2 2 , and for which the detector is not on the accelerator site. The Snowmass N2L working group met to discuss the issues facing such experiments. The Fermilab Program Advisory Committee adopted several recommendations concerning the Fermilab neutrino program at their Aspen meeting immediately prior to the Snowmass Workshop. This heightened the attention for the proposals to use Fermilab for a long-baseline neutrino experiment at the workshop. The plan for a neutrino oscillation program at Brookhaven was also thoroughly discussed. Opportunities at CERN were considered, particularly the use of detectors at the Gran Sasso laboratory. The idea to build a neutrino beam from KEK towards Superkamiokande was not discussed at the Snowmass meeting, but there has been considerable development of this idea since then. Brookhaven and KEK would use low energy neutrino beams, while FNAL and CERN would plan have medium energy beams. This report will summarize a few topics common to LBL proposals and attempt to give a snapshot of where things stand in this fast developing field

  18. 40 CFR 80.1285 - How does a refiner apply for a benzene baseline?

    Science.gov (United States)

    2010-07-01

    ... baseline? 80.1285 Section 80.1285 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... (abt) Program § 80.1285 How does a refiner apply for a benzene baseline? (a) A benzene baseline... credits. (b) For U.S. Postal delivery, the benzene baseline application shall be sent to: Attn: MSAT2...

  19. Analysis of Seasonal Signal in GPS Short-Baseline Time Series

    Science.gov (United States)

    Wang, Kaihua; Jiang, Weiping; Chen, Hua; An, Xiangdong; Zhou, Xiaohui; Yuan, Peng; Chen, Qusen

    2018-04-01

    Proper modeling of seasonal signals and their quantitative analysis are of interest in geoscience applications, which are based on position time series of permanent GPS stations. Seasonal signals in GPS short-baseline (paper, to better understand the seasonal signal in GPS short-baseline time series, we adopted and processed six different short-baselines with data span that varies from 2 to 14 years and baseline length that varies from 6 to 1100 m. To avoid seasonal signals that are overwhelmed by noise, each of the station pairs is chosen with significant differences in their height (> 5 m) or type of the monument. For comparison, we also processed an approximately zero baseline with a distance of pass-filtered (BP) noise is valid for approximately 40% of the baseline components, and another 20% of the components can be best modeled by a combination of the first-order Gauss-Markov (FOGM) process plus white noise (WN). The TEM displacements are then modeled by considering the monument height of the building structure beneath the GPS antenna. The median contributions of TEM to the annual amplitude in the vertical direction are 84% and 46% with and without additional parts of the monument, respectively. Obvious annual signals with amplitude > 0.4 mm in the horizontal direction are observed in five short-baselines, and the amplitudes exceed 1 mm in four of them. These horizontal seasonal signals are likely related to the propagation of daily/sub-daily TEM displacement or other signals related to the site environment. Mismodeling of the tropospheric delay may also introduce spurious seasonal signals with annual amplitudes of 5 and 2 mm, respectively, for two short-baselines with elevation differences greater than 100 m. The results suggest that the monument height of the additional part of a typical GPS station should be considered when estimating the TEM displacement and that the tropospheric delay should be modeled cautiously, especially with station pairs with

  20. IEA Wind Task 26: Offshore Wind Farm Baseline Documentation

    Energy Technology Data Exchange (ETDEWEB)

    Smart, Gavin [Offshore Renewable Energy Catapult, Blyth, Northumberland (United Kingdom); Smith, Aaron [National Renewable Energy Lab. (NREL), Golden, CO (United States); Warner, Ethan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sperstad, Iver Bakken [SINTEF Energy Research, Trondheim (Norway); Prinsen, Bob [Ecofys, Utrecht (Netherlands). TKI Wind Op Zee; Lacal-Arantegui, Roberto [European Commission Joint Research Centre (JRC), Brussels (Belgium)

    2016-06-02

    This document has been produced to provide the definition and rationale for the Baseline Offshore Wind Farm established within IEA Wind Task 26--Cost of Wind Energy. The Baseline has been developed to provide a common starting point for country comparisons and sensitivity analysis on key offshore wind cost and value drivers. The baseline project reflects an approximate average of the characteristics of projects installed between 2012 and 2014, with the project life assumed to be 20 years. The baseline wind farm is located 40 kilometres (km) from construction and operations and maintenance (O&M) ports and from export cable landfall. The wind farm consists of 100 4-megawatt (MW) wind turbines mounted on monopile foundations in an average water depth of 25 metres (m), connected by 33-kilovolt (kV) inter-array cables. The arrays are connected to a single offshore substation (33kV/220kV) mounted on a jacket foundation, with the substation connected via a single 220kV export cable to an onshore substation, 10km from landfall. The wind farm employs a port-based O&M strategy using crew-transfer vessels.

  1. Consideration of the baseline environment in examples of voluntary SEAs from Scotland

    International Nuclear Information System (INIS)

    Wright, Fiona

    2007-01-01

    Evidence from analysing and evaluating examples of three voluntary SEAs prepared in Scotland in the mid-late 1990s showed that different spatial and temporal scales were used when providing a baseline environment description. The SEAs analysed were prepared for: a wind farm siting programme that looked at national and short-term impacts; a land use plan that looked at regional and short-term impacts; and a transport plan that examined local and medium-term impacts. It was found that the two SEAs prepared by local government only considered impacts on the baseline environment within their jurisdictional boundaries whilst the SEA prepared by the private business considered impacts on the national baseline. A mixture of baseline data about planning, economic, environmental and social issues were included in the SEAs, however, evidence suggested that each SEA only focussed on those baseline features that might be significantly affected by the proposal. Each SEA also made extensive use of existing baseline information available from a variety of sources including local, and central government records and information from statutory bodies. All of the SEAs acknowledged that baseline data deficiencies existed and in certain cases steps were taken to obtain primary field data to help address these, however, it was also acknowledged that resource restrictions and decision-making deadlines limited the amount of primary baseline data that could be collected

  2. Baselining PMU Data to Find Patterns and Anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Amidan, Brett G.; Follum, James D.; Freeman, Kimberly A.; Dagle, Jeffery E.

    2016-10-25

    This paper looks at the application of situational awareness methodologies with respect to power grid data. These methodologies establish baselines that look for typical patterns and atypical behavior in the data. The objectives of the baselining analyses are to provide: real-time analytics, the capability to look at historical trends and events, and reliable predictions of the near future state of the grid. Multivariate algorithms were created to establish normal baseline behavior and then score each moment in time according to its variance from the baseline. Detailed multivariate analytical techniques are described in this paper that produced ways to identify typical patterns and atypical behavior. In this case, atypical behavior is behavior that is unenvisioned. Visualizations were also produced to help explain the behavior that was identified mathematically. Examples are shown to help describe how to read and interpret the analyses and visualizations. Preliminary work has been performed on PMU data sets from BPA (Bonneville Power Administration) and EI (Eastern Interconnect). Actual results are not fully shown here because of confidentiality issues. Comparisons between atypical events found mathematically and actual events showed that many of the actual events are also atypical events; however there are many atypical events that do not correlate to any actual events. Additional work needs to be done to help classify the atypical events into actual events, so that the importance of the events can be better understood.

  3. 200-BP-5 operable unit Technical Baseline report

    International Nuclear Information System (INIS)

    Jacques, I.D.; Kent, S.K.

    1991-10-01

    This report supports development of a remedial investigation/feasibility study work plan for the 200-BP-5 operable unit. The report summarizes baseline information for waste sites and unplanned release sites located in the 200-BP-5 operable unit. The sites were investigated by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (Westinghouse Hanford). The investigation consisted of review and evaluation of current and historical Hanford Site reports, drawings, and photographs, and was supplemented with recent inspections of the Hanford Site and employee interviews. No field investigations or sampling were conducted

  4. Evidence of the shifting baseline syndrome in ethnobotanical research.

    Science.gov (United States)

    Hanazaki, Natalia; Herbst, Dannieli Firme; Marques, Mel Simionato; Vandebroek, Ina

    2013-11-14

    The shifting baseline syndrome is a concept from ecology that can be analyzed in the context of ethnobotanical research. Evidence of shifting baseline syndrome can be found in studies dealing with intracultural variation of knowledge, when knowledge from different generations is compared and combined with information about changes in the environment and/or natural resources. We reviewed 84 studies published between 1993 and 2012 that made comparisons of ethnobotanical knowledge according to different age classes. After analyzing these studies for evidence of the shifting baseline syndrome (lower knowledge levels in younger generations and mention of declining abundance of local natural resources), we searched within these studies for the use of the expressions "cultural erosion", "loss of knowledge", or "acculturation". The studies focused on different groups of plants (e.g. medicinal plants, foods, plants used for general purposes, or the uses of specific important species). More than half of all 84 studies (57%) mentioned a concern towards cultural erosion or knowledge loss; 54% of the studies showed evidence of the shifting baseline syndrome; and 37% of the studies did not provide any evidence of shifting baselines (intergenerational knowledge differences but no information available about the abundance of natural resources). The general perception of knowledge loss among young people when comparing ethnobotanical repertoires among different age groups should be analyzed with caution. Changes in the landscape or in the abundance of plant resources may be associated with changes in ethnobotanical repertoires held by people of different age groups. Also, the relationship between the availability of resources and current plant use practices rely on a complexity of factors. Fluctuations in these variables can cause changes in the reference (baseline) of different generations and consequently be responsible for differences in intergenerational knowledge. Unraveling

  5. A proposal to create an extension to the European baseline series.

    Science.gov (United States)

    Wilkinson, Mark; Gallo, Rosella; Goossens, An; Johansen, Jeanne D; Rustemeyer, Thomas; Sánchez-Pérez, Javier; Schuttelaar, Marie L; Uter, Wolfgang

    2018-02-01

    The current European baseline series consists of 30 allergens, and was last updated in 2015. To use data from the European Surveillance System on Contact Allergies (ESSCA) to propose an extension to the European baseline series in response to changes in environmental exposures. Data from departmental and national extensions to the baseline series, together with some temporary additions from departments contributing to the ESSCA, were collated during 2013-2014. In total, 31689 patients were patch tested in 46 European departments. Many departments and national groups already consider the current European baseline series to be a suboptimal screen, and use their own extensions to it. The haptens tested are heterogeneous, although there are some consistent themes. Potential haptens to include in an extension to the European baseline series comprise sodium metabisulfite, formaldehyde-releasing preservatives, additional markers of fragrance allergy, propolis, Compositae mix, and 2-hydroxyethyl methacrylate. In combination with other published work from the ESSCA, changes to the current European baseline series are proposed for discussion. As well as addition of the allergens listed above, it is suggested that primin and clioquinol should be deleted from the series, owing to reduced environmental exposure. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. 41 CFR 109-1.5202 - Establishment of a personal property holdings baseline.

    Science.gov (United States)

    2010-07-01

    ... personal property holdings baseline. 109-1.5202 Section 109-1.5202 Public Contracts and Property Management...-1.5202 Establishment of a personal property holdings baseline. (a) If the contractor is a new... baseline or may perform a complete physical inventory of all personal property. This physical inventory is...

  7. 75 FR 30014 - Consumers Energy Company; Notice of Baseline Filing

    Science.gov (United States)

    2010-05-28

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-25-000] Consumers Energy Company; Notice of Baseline Filing May 21, 2010. Take notice that on May 17, 2010, Consumers Energy Company (Consumers) submitted a baseline filing of its Statement of Operating Conditions for the...

  8. Waste management project technical baseline description

    International Nuclear Information System (INIS)

    Sederburg, J.P.

    1997-01-01

    A systems engineering approach has been taken to describe the technical baseline under which the Waste Management Project is currently operating. The document contains a mission analysis, function analysis, requirement analysis, interface definitions, alternative analysis, system definition, documentation requirements, implementation definitions, and discussion of uncertainties facing the Project

  9. Historical baselines of coral cover on tropical reefs as estimated by expert opinion

    Directory of Open Access Journals (Sweden)

    Tyler D. Eddy

    2018-01-01

    Full Text Available Coral reefs are important habitats that represent global marine biodiversity hotspots and provide important benefits to people in many tropical regions. However, coral reefs are becoming increasingly threatened by climate change, overfishing, habitat destruction, and pollution. Historical baselines of coral cover are important to understand how much coral cover has been lost, e.g., to avoid the ‘shifting baseline syndrome’. There are few quantitative observations of coral reef cover prior to the industrial revolution, and therefore baselines of coral reef cover are difficult to estimate. Here, we use expert and ocean-user opinion surveys to estimate baselines of global coral reef cover. The overall mean estimated baseline coral cover was 59% (±19% standard deviation, compared to an average of 58% (±18% standard deviation estimated by professional scientists. We did not find evidence of the shifting baseline syndrome, whereby respondents who first observed coral reefs more recently report lower estimates of baseline coral cover. These estimates of historical coral reef baseline cover are important for scientists, policy makers, and managers to understand the extent to which coral reefs have become depleted and to set appropriate recovery targets.

  10. Historical baselines of coral cover on tropical reefs as estimated by expert opinion.

    Science.gov (United States)

    Eddy, Tyler D; Cheung, William W L; Bruno, John F

    2018-01-01

    Coral reefs are important habitats that represent global marine biodiversity hotspots and provide important benefits to people in many tropical regions. However, coral reefs are becoming increasingly threatened by climate change, overfishing, habitat destruction, and pollution. Historical baselines of coral cover are important to understand how much coral cover has been lost, e.g., to avoid the 'shifting baseline syndrome'. There are few quantitative observations of coral reef cover prior to the industrial revolution, and therefore baselines of coral reef cover are difficult to estimate. Here, we use expert and ocean-user opinion surveys to estimate baselines of global coral reef cover. The overall mean estimated baseline coral cover was 59% (±19% standard deviation), compared to an average of 58% (±18% standard deviation) estimated by professional scientists. We did not find evidence of the shifting baseline syndrome, whereby respondents who first observed coral reefs more recently report lower estimates of baseline coral cover. These estimates of historical coral reef baseline cover are important for scientists, policy makers, and managers to understand the extent to which coral reefs have become depleted and to set appropriate recovery targets.

  11. Exploring non standard physics in long-baseline neutrino oscillation experiments

    International Nuclear Information System (INIS)

    Chatterjee, Sabya Sachi

    2015-01-01

    After the recent discovery of large th ( 13), the focus has been shifted to address the remaining fundamental issues like neutrino mass ordering and CP-violation in leptonic sector. Future proposed Long-Baseline facilities like DUNE (1300 km baseline from FNAL to Homestake) and LBNO (2290 km baseline from CERN to Pyhasalmi) are well suited to address these issues at high confidence level. Not only to the standard framework, these experiments are highly capable to look for some new physics beyond the Standard Model scenario. In this work, we explore whether these high precision future facilities are sensitive to new U(1) global symmetries and upto which confidence level. (author)

  12. Way to increase the user access at the LCLS baseline

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg; Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2010-10-15

    Although the LCLS photon beam is meant for a single user, the baseline undulator is long enough to serve two users simultaneously. To this end, we propose a setup composed of two simple elements: an X-ray mirror pair for X-ray beam deflection, and a short (4 m-long) magnetic chicane, which creates an offset for mirror pair installation in the middle of the baseline undulator. The insertable mirror pair can be used for spatial separation of the X-ray beams generated in the first and in the second half of the baseline undulator. The method of deactivating one half and activating another half of the undulator is based on the rapid switching of the FEL amplification process. As proposed elsewhere, using a kicker installed upstream of the LCLS baseline undulator and an already existing corrector in the first half of the undulator, it is possible to rapidly switch the X-ray beam from one user to another, thus providing two active beamlines at any time. We present simulation results dealing with the LCLS baseline, and show that it is possible to generate two saturated SASE X-ray beams in the whole 0.8-8 keV photon energy range in the same baseline undulator. These can be exploited to serve two users. Implementation of the proposed technique does not perturb the baseline mode of operation of the LCLS undulator. Moreover, the magnetic chicane setup is very flexible, and can be used as a self-seeding setup too. We present simulation results for the LCLS baseline undulator with SHAB (second harmonic afterburner) and show that one can produce monochromatic radiation at the 2nd harmonic as well as at the 1st. We describe an efficient way for obtaining multi-user operation at the LCLS hard X-ray FEL. To this end, a photon beam distribution system based on the use of crystals in the Bragg reflection geometry is proposed. The reflectivity of crystal deflectors can be switched fast enough by flipping the crystals with piezoelectric devices similar to those for X-ray phase retarders

  13. Mechanical Thrombectomy in Elderly Stroke Patients with Mild-to-Moderate Baseline Disability.

    Science.gov (United States)

    Slawski, Diana E; Salahuddin, Hisham; Shawver, Julie; Kenmuir, Cynthia L; Tietjen, Gretchen E; Korsnack, Andrea; Zaidi, Syed F; Jumaa, Mouhammad A

    2018-04-01

    The number of elderly patients suffering from ischemic stroke is rising. Randomized trials of mechanical thrombectomy (MT) generally exclude patients over the age of 80 years with baseline disability. The aim of this study was to understand the efficacy and safety of MT in elderly patients, many of whom may have baseline impairment. Between January 2015 and April 2017, 96 patients ≥80 years old who underwent MT for stroke were selected for a chart review. The data included baseline characteristics, time to treatment, the rate of revascularization, procedural complications, mortality, and 90-day good outcome defined as a modified Rankin Scale (mRS) score of 0-2 or return to baseline. Of the 96 patients, 50 had mild baseline disability (mRS score 0-1) and 46 had moderate disability (mRS score 2-4). Recanalization was achieved in 84% of the patients, and the rate of symptomatic hemorrhage was 6%. At 90 days, 34% of the patients had a good outcome. There were no significant differences in good outcome between those with mild and those with moderate baseline disability (43 vs. 24%, p = 0.08), between those aged ≤85 and those aged > 85 years (40.8 vs. 26.1%, p = 0.19), and between those treated within and those treated beyond 8 h (39 vs. 20%, p = 0.1). The mortality rate was 38.5% at 90 days. The Alberta Stroke Program Early CT Score (ASPECTS) and the National Institutes of Health Stroke Scale (NIHSS) predicted good outcome regardless of baseline disability ( p baseline disability, and delayed treatment are associated with sub-optimal outcomes after MT. However, redefining good outcome to include return to baseline functioning demonstrates that one-third of this patient population benefits from MT, suggesting the real-life utility of this treatment.

  14. 77 FR 31841 - Hope Gas, Inc.; Notice of Baseline Filing

    Science.gov (United States)

    2012-05-30

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR12-23-001] Hope Gas, Inc.; Notice of Baseline Filing Take notice that on May 16, 2012, Hope Gas, Inc. (Hope Gas) submitted a revised baseline filing of their Statement of Operating Conditions for services provided under Section 311 of the...

  15. 77 FR 26535 - Hope Gas, Inc.; Notice of Baseline Filing

    Science.gov (United States)

    2012-05-04

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR12-23-000] Hope Gas, Inc.; Notice of Baseline Filing Take notice that on April 26, 2012, Hope Gas, Inc. (Hope Gas) submitted a baseline filing of their Statement of Operating Conditions for services provided under Section 311 of the...

  16. 75 FR 33799 - EasTrans, LLC; Notice of Baseline Filing

    Science.gov (United States)

    2010-06-15

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-30-000] EasTrans, LLC; Notice of Baseline Filing June 8, 2010. Take notice that on June 4, 2010, EasTrans, LLC submitted a baseline filing of its Statement of Operating Conditions for services provided under section 311 of the...

  17. A Systematic Review and Meta-Analysis of Baseline Ohip-Edent Scores.

    Science.gov (United States)

    Duale, J M J; Patel, Y A; Wu, J; Hyde, T P

    2018-03-01

    OHIP-EDENT is widely used in the literature to assess Oral-Health-Related-Quality-of-Life (OHRQoL) for edentulous patients. However the normal variance and mean of the baseline OHIP scores has not been reported. It would facilitate critical appraisal of studies if we had knowledge of the normal variation and mean of baseline OHIP-EDENT scores. An established figure for baseline OHIP-EDENT, obtained from a meta-analysis, would simplify comparisons of studies and quantify variations in initial OHRQoL of the trial participants. The aim of this study is to quantify a normal baseline value for pre-operative OHIP-EDENT scores by a systematic review and meta-analysis of the available literature. A systematic literature review was carried. 83 papers were identified that included OHIP-EDENT values. After screening and eligibility assessment, 7 papers were selected and included in the meta-analysis. A meta-analysis for the 7 papers by a random-effect model yielded a mean baseline OHIP-EDENT score of 28.63 with a 95% Confidence intervals from 21.93 to 35.34. A pre-operative baseline OHIP-EDENT has been established by meta-analysis of published papers. This will facilitate the comparison of the initial OHRQoL of one study population to that found elsewhere in the published literature. Copyright© 2018 Dennis Barber Ltd.

  18. Base-line studies for DAE establishments

    International Nuclear Information System (INIS)

    Puranik, V.D.

    2012-01-01

    The Department of Atomic Energy has establishments located in various regions of the country and they include front-end fuel cycle facilities, nuclear power stations, back-end fuel cycle facilities and facilities for research and societal applications. These facilities handle naturally occurring radionuclides such as uranium, thorium and a variety of man-made radionuclides. These radionuclides are handled with utmost care so that they do not affect adversely the occupational workers or the members of public residing nearby. There is safety culture of the highest standard existing in all DAE establishments and it matches with the international standards. In addition, there is a perpetual environmental monitoring program carried out by the Environmental Survey Laboratories (ESLs) located at all DAE establishments. The environmental data generated by such program is studied regularly by experts to ensure compliance with the regulatory requirements. The regulatory requirements in the country are of international standards and ensure adequate protection of workers and members of public. In addition to such continued monitoring program and studies being carried out for the ongoing projects, base-line studies are carried out for all the new projects of the DAE. The purpose of the base-line studies is to establish a detailed base-line data set for a new DAE location well before the foundation stone is laid, so that the data collected when there is no departmental activity can be compared with the data generated later by the ESL. The data so generated is site specific and it varies from place to place depending upon the location of the site, e.g., inland or coastal, the presence of water bodies and pattern of irrigation, the geological characteristics of the location, the local culture and habits of the people, population density and urban or rural background. The data to be recorded as base-line data is generated over a period of at least one year covering all the seasons

  19. Production Facility SCADA Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Holloway, Michael Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Baily, Scott A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wheat, Robert Mitchell Jr. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-03-23

    The following report covers FY 14 activities to develop supervisory control and data acquisition (SCADA) system for the Northstar Moly99 production facility. The goal of this effort is to provide Northstar with a baseline system design.

  20. National Cyberethics, Cybersafety, Cybersecurity Baseline Study

    Science.gov (United States)

    Education Digest: Essential Readings Condensed for Quick Review, 2009

    2009-01-01

    This article presents findings from a study that explores the nature of the Cyberethics, Cybersafety, and Cybersecurity (C3) educational awareness policies, initiatives, curriculum, and practices currently taking place in the U.S. public and private K-12 educational settings. The study establishes baseline data on C3 awareness, which can be used…

  1. Linear MALDI-ToF simultaneous spectrum deconvolution and baseline removal.

    Science.gov (United States)

    Picaud, Vincent; Giovannelli, Jean-Francois; Truntzer, Caroline; Charrier, Jean-Philippe; Giremus, Audrey; Grangeat, Pierre; Mercier, Catherine

    2018-04-05

    Thanks to a reasonable cost and simple sample preparation procedure, linear MALDI-ToF spectrometry is a growing technology for clinical microbiology. With appropriate spectrum databases, this technology can be used for early identification of pathogens in body fluids. However, due to the low resolution of linear MALDI-ToF instruments, robust and accurate peak picking remains a challenging task. In this context we propose a new peak extraction algorithm from raw spectrum. With this method the spectrum baseline and spectrum peaks are processed jointly. The approach relies on an additive model constituted by a smooth baseline part plus a sparse peak list convolved with a known peak shape. The model is then fitted under a Gaussian noise model. The proposed method is well suited to process low resolution spectra with important baseline and unresolved peaks. We developed a new peak deconvolution procedure. The paper describes the method derivation and discusses some of its interpretations. The algorithm is then described in a pseudo-code form where the required optimization procedure is detailed. For synthetic data the method is compared to a more conventional approach. The new method reduces artifacts caused by the usual two-steps procedure, baseline removal then peak extraction. Finally some results on real linear MALDI-ToF spectra are provided. We introduced a new method for peak picking, where peak deconvolution and baseline computation are performed jointly. On simulated data we showed that this global approach performs better than a classical one where baseline and peaks are processed sequentially. A dedicated experiment has been conducted on real spectra. In this study a collection of spectra of spiked proteins were acquired and then analyzed. Better performances of the proposed method, in term of accuracy and reproductibility, have been observed and validated by an extended statistical analysis.

  2. 78 FR 4830 - National Advisory Committee on Microbiological Criteria for Foods; Reestablishment

    Science.gov (United States)

    2013-01-23

    .../NACMCF/index.asp . FOR FURTHER INFORMATION CONTACT: Karen Thomas, Advisory Committee Specialist, U.S... Meat Inspection Act (FMIA), the Poultry Products Inspection Act (PPIA), and the Egg Products Inspection...

  3. Baseline concentration of {sup 210}Po in Sargassum from the Northern Gulf

    Energy Technology Data Exchange (ETDEWEB)

    Uddin, S.; Bebhehani, M.; Talebi, L. [Kuwait Institute for Scientific Research (Kuwait)

    2014-07-01

    The concentration of the {sup 210}Po is of enormous interest because of its large contribution to the natural radiation dose received by marine organisms and human populations consuming seafood. In fact natural {sup 210}Po is responsible for higher radiation doses to humans consuming marine products than is plutonium and other man-made radionuclides. Many marine organisms are capable of concentrating {sup 210}Po in their tissues. {sup 210}Po is an alpha emitter in the {sup 238}U series, with 138-d half-life, that is supplied to seawater from atmospheric inputs and river runoff, however, the main source of {sup 210}Po in the environment is {sup 222}Rn exhalation from the ground. Assessing the impact of radionuclides in the environment requires the establishment of baseline levels in the environmental compartments. The objective of this study was to establish baseline levels in Sargassum. Two most common species of Sargassum found in the northern Gulf were analysed for {sup 210}Po. These macro-algae were collected from three different locations during January 2013. This study sets the baseline for {sup 210}Po concentration in northern Gulf, {sup 210}Po is absorbed from water and concentrated by Phytoplankton and macro-algae. This concentrated {sup 210}Po can then be passed along to the next trophic level of the marine food web. The {sup 210}Po concentration measured in Sargassum boveanum (4.405 - 4.952 BqKg{sup -1}) was significantly higher (p>0.084) than Sargassum oligocystum (3.838 - 4.358 BqKg{sup -1}). The {sup 210}Po concentration in these seaweeds from the Arabian/Persian Gulf were substantially lower than those found in various Phytoplankton and macro-algae species from other regions; this may be due to the lower background {sup 210}Po concentration in the Kuwait marine waters (0.282 - 0.382 mBq l{sup -1}). The {sup 210}Po concentrations in seawater measured at the 3 stations during January 2013 were less than those reported previously from the same region

  4. Atmospheric pressure loading parameters from very long baseline interferometry observations

    Science.gov (United States)

    Macmillan, D. S.; Gipson, John M.

    1994-01-01

    Atmospheric mass loading produces a primarily vertical displacement of the Earth's crust. This displacement is correlated with surface pressure and is large enough to be detected by very long baseline interferometry (VLBI) measurements. Using the measured surface pressure at VLBI stations, we have estimated the atmospheric loading term for each station location directly from VLBI data acquired from 1979 to 1992. Our estimates of the vertical sensitivity to change in pressure range from 0 to -0.6 mm/mbar depending on the station. These estimates agree with inverted barometer model calculations (Manabe et al., 1991; vanDam and Herring, 1994) of the vertical displacement sensitivity computed by convolving actual pressure distributions with loading Green's functions. The pressure sensitivity tends to be smaller for stations near the coast, which is consistent with the inverted barometer hypothesis. Applying this estimated pressure loading correction in standard VLBI geodetic analysis improves the repeatability of estimated lengths of 25 out of 37 baselines that were measured at least 50 times. In a root-sum-square (rss) sense, the improvement generally increases with baseline length at a rate of about 0.3 to 0.6 ppb depending on whether the baseline stations are close to the coast. For the 5998-km baseline from Westford, Massachusetts, to Wettzell, Germany, the rss improvement is about 3.6 mm out of 11.0 mm. The average rss reduction of the vertical scatter for inland stations ranges from 2.7 to 5.4 mm.

  5. Safety Evaluation of the ESP Sludge Washing Baselines Runs. Revision 1

    International Nuclear Information System (INIS)

    Gupta, M.K.

    1994-08-01

    The purpose is to provide the technical basis for the evaluation of Unreviewed Safety Question for the Extended Sludge Processing (ESP) Sludge Washing Baseline Runs. The Baseline runs are necessary: to ascertain the mechanical fitness of the equipment and modifications not operated since 1988 and to resolve technical questions associated with process control; i.e., sludge suspension, sludge settling, heat transfer, and temperature control. These issues need to be resolved prior to resumption of normal ESP operations. The equipment used for the Baseline runs are Tanks 42H and 51H and their associated equipment

  6. Network meta-analysis of disconnected networks: How dangerous are random baseline treatment effects?

    Science.gov (United States)

    Béliveau, Audrey; Goring, Sarah; Platt, Robert W; Gustafson, Paul

    2017-12-01

    In network meta-analysis, the use of fixed baseline treatment effects (a priori independent) in a contrast-based approach is regularly preferred to the use of random baseline treatment effects (a priori dependent). That is because, often, there is not a need to model baseline treatment effects, which carry the risk of model misspecification. However, in disconnected networks, fixed baseline treatment effects do not work (unless extra assumptions are made), as there is not enough information in the data to update the prior distribution on the contrasts between disconnected treatments. In this paper, we investigate to what extent the use of random baseline treatment effects is dangerous in disconnected networks. We take 2 publicly available datasets of connected networks and disconnect them in multiple ways. We then compare the results of treatment comparisons obtained from a Bayesian contrast-based analysis of each disconnected network using random normally distributed and exchangeable baseline treatment effects to those obtained from a Bayesian contrast-based analysis of their initial connected network using fixed baseline treatment effects. For the 2 datasets considered, we found that the use of random baseline treatment effects in disconnected networks was appropriate. Because those datasets were not cherry-picked, there should be other disconnected networks that would benefit from being analyzed using random baseline treatment effects. However, there is also a risk for the normality and exchangeability assumption to be inappropriate in other datasets even though we have not observed this situation in our case study. We provide code, so other datasets can be investigated. Copyright © 2017 John Wiley & Sons, Ltd.

  7. Symbiotic maple saps minimize disruption of the mice intestinal microbiota after oral antibiotic administration.

    Science.gov (United States)

    Hammami, Riadh; Ben Abdallah, Nour; Barbeau, Julie; Fliss, Ismail

    2015-01-01

    This study was undertaken to evaluate the in vivo impact of new symbiotic products based on liquid maple sap or its concentrate. Sap and concentrate, with or without inulin (2%), were inoculated with Bifidobacterium lactis Bb12 and Lactobacillus rhamnosus GG valio at initial counts of 2-4 × 10(8) cfu mL(-1). The experiments started with intra-gastric administration of antibiotic (kanamycin 40 mg in 0.1 cc) (to induce microbiota disturbance and/or diarrhea) to 3-to-5-week-old C57BL/6 female mice followed by a combination of prebiotic and probiotics included in the maple sap or its concentrate for a week. The combination inulin and probiotics in maple sap and concentrate appeared to minimize the antibiotic-induced breakdown of mice microbiota with a marked effect on bifidobacterium and bacteroides levels, thus permitting a more rapid re-establishment of the baseline microbiota levels. Results suggest that maple sap and its concentrate represent good candidates for the production of non-dairy functional foods.

  8. Exploring product and service innovation similarities and differences

    NARCIS (Netherlands)

    Nijssen, E.J.; Hillebrand, B.; Vermeulen, P.A.M.; Kemp, R.G.M.

    2006-01-01

    This paper aims to provide an initial step towards a synthesis of new service and new product development research. Using a baseline model of innovation, applicable to innovation in general, we hypothesize differential context effects between new service and product development in order to better

  9. Control advances for achieving the ITER baseline scenario on KSTAR

    Science.gov (United States)

    Eidietis, N. W.; Barr, J.; Hahn, S. H.; Humphreys, D. A.; in, Y. K.; Jeon, Y. M.; Lanctot, M. J.; Mueller, D.; Walker, M. L.

    2017-10-01

    Control methodologies developed to enable successful production of ITER baseline scenario (IBS) plasmas on the superconducting KSTAR tokamak are presented: decoupled vertical control (DVC), real-time feedforward (rtFF) calculation, and multi-input multi-output (MIMO) X-point control. DVC provides fast vertical control with the in-vessel control coils (IVCC) while sharing slow vertical control with the poloidal field (PF) coils to avoid IVCC saturation. rtFF compensates for inaccuracies in offline PF current feedforward programming, allowing reduction or removal of integral gain (and its detrimental phase lag) from the shape controller. Finally, MIMO X-point control provides accurate positioning of the X-point despite low controllability due to the large distance between coils and plasma. Combined, these techniques enabled achievement of IBS parameters (q95 = 3.2, βN = 2) with a scaled ITER shape on KSTAR. n =2 RMP response displays a strong dependence upon this shaping. Work supported by the US DOE under Award DE-SC0010685 and the KSTAR project.

  10. Baseline for beached marine debris on Sand Island, Midway Atoll

    Science.gov (United States)

    Ribic, Christine; Seba B. Sheavly,; John Klavitter,

    2012-01-01

    Baseline measurements were made of the amount and weight of beached marine debris on Sand Island, Midway Atoll, June 2008–July 2010. On 23 surveys, 32,696 total debris objects (identifiable items and pieces) were collected; total weight was 740.4 kg. Seventy-two percent of the total was pieces; 91% of the pieces were made of plastic materials. Pieces were composed primarily of polyethylene and polypropylene. Identifiable items were 28% of the total; 88% of the identifiable items were in the fishing/aquaculture/shipping-related and beverage/household products-related categories. Identifiable items were lowest during April–August, while pieces were at their lowest during June–August. Sites facing the North Pacific Gyre received the most debris and proportionately more pieces. More debris tended to be found on Sand Island when the Subtropical Convergence Zone was closer to the Atoll. This information can be used for potential mitigation and to understand the impacts of large-scale events such as the 2011 Japanese tsunami.

  11. Spent Nuclear Fuel Project technical baseline document. Fiscal year 1995: Volume 1, Baseline description

    International Nuclear Information System (INIS)

    Womack, J.C.; Cramond, R.; Paedon, R.J.

    1995-01-01

    This document is a revision to WHC-SD-SNF-SD-002, and is issued to support the individual projects that make up the Spent Nuclear Fuel Project in the lower-tier functions, requirements, interfaces, and technical baseline items. It presents results of engineering analyses since Sept. 1994. The mission of the SNFP on the Hanford site is to provide safety, economic, environmentally sound management of Hanford SNF in a manner that stages it to final disposition. This particularly involves K Basin fuel, although other SNF is involved also

  12. Mass hierarchy sensitivity of medium baseline reactor neutrino experiments with multiple detectors

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hong-Xin, E-mail: hxwang@iphy.me [Department of Physics, Nanjing University, Nanjing 210093 (China); Zhan, Liang; Li, Yu-Feng; Cao, Guo-Fu [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Chen, Shen-Jian [Department of Physics, Nanjing University, Nanjing 210093 (China)

    2017-05-15

    We report the neutrino mass hierarchy (MH) determination of medium baseline reactor neutrino experiments with multiple detectors, where the sensitivity of measuring the MH can be significantly improved by adding a near detector. Then the impact of the baseline and target mass of the near detector on the combined MH sensitivity has been studied thoroughly. The optimal selections of the baseline and target mass of the near detector are ∼12.5 km and ∼4 kton respectively for a far detector with the target mass of 20 kton and the baseline of 52.5 km. As typical examples of future medium baseline reactor neutrino experiments, the optimal location and target mass of the near detector are selected for the specific configurations of JUNO and RENO-50. Finally, we discuss distinct effects of the reactor antineutrino energy spectrum uncertainty for setups of a single detector and double detectors, which indicate that the spectrum uncertainty can be well constrained in the presence of the near detector.

  13. Dependence of optimum baseline setting on scatter fraction and detector response function

    International Nuclear Information System (INIS)

    Atkins, F.B.; Beck, R.N.; Hoffer, P.B.; Palmer, D.

    1977-01-01

    A theoretical and experimental investigation has been undertaken to determine the dependence of an optimum baseline setting on the amount of scattered radiation recorded in a spectrum, and on the energy resolution of the detector. In particular, baseline settings were established for clinical examinations which differed greatly in the amount of scattered radiation, namely, liver and brain scans, for which individual variations were found to produce only minimal fluctuations in the optimum baseline settings. This analysis resulted in an optimum baseline setting of 125.0 keV for brain scans and 127.2 keV for liver scans for the scintillation camera used in these studies. The criterion that was used is based on statistical considerations of the measurement of an unscattered component in the presence of a background due to scattered photons. The limitations of such a criterion are discussed, and phantom images are presented to illustrate these effects at various baseline settings. (author)

  14. A comparison of baseline methodologies for 'Reducing Emissions from Deforestation and Degradation'

    Directory of Open Access Journals (Sweden)

    Kok Kasper

    2009-07-01

    Full Text Available Abstract Background A mechanism for emission reductions from deforestation and degradation (REDD is very likely to be included in a future climate agreement. The choice of REDD baseline methodologies will crucially influence the environmental and economic effectiveness of the climate regime. We compare three different historical baseline methods and one innovative dynamic model baseline approach to appraise their applicability under a future REDD policy framework using a weighted multi-criteria analysis. Results The results show that each baseline method has its specific strengths and weaknesses. Although the dynamic model allows for the best environmental and for comparatively good economic performance, its high demand for data and technical capacity limit the current applicability in many developing countries. Conclusion The adoption of a multi-tier approach will allow countries to select the baseline method best suiting their specific capabilities and data availability while simultaneously ensuring scientific transparency, environmental effectiveness and broad political support.

  15. Effects of climate factors and vegetation on the CO2 fluxes and δ13C from re-established grassland

    Science.gov (United States)

    Bezyk, Yaroslav; Dorodnikov, Maxim; Sówka, Izabela

    2017-11-01

    The relationship between stable carbon isotope composition (δ13C -CO2) of soil CO2 flux, vegetation cover and weather conditions was investigated in a short-term campaign at a temperate re-established grassland in Germany. During August-September 2016, we measured surface CO2 flux with a closed-chamber method at high and low soil moisture content (`wet', `dry'), with and without above ground vegetation (`planted', `clear-cut') and estimated the effects of treatments on respective δ13C -CO2 values. The concentration and stable carbon isotope composition of CO2 were determined using the gas chromatography and mass spectrometry analyses. The δ13C -CO2 of the soil fluxes decreased over sampling time for the `dry-warm' conditions and canopy manipulation. The ecosystem-derived δ13C -CO2 values (corrected for the atmospheric δ13C -CO2) which included predominately soil-and rhizosphere respiration were -26.2 ± 0.8‰ for the `dry-warm' conditions and decreased down to -28.1 ± 1.4‰ over a period of 28 days from late August to the end of September. The decrease coincided with the lowering of CO2 flux and could be attributed to changes in plant physiological processes at the end of the vegetation season. Though the removal of shoots did not significantly affect the δ13C -CO2 values as compared with the control, the pattern of further δ13C -CO2 decrease (down to -28.8 ± 0.8‰) supported the role of living vegetation in a contribution of 13C-enriched CO2 to the ecosystem respiration.

  16. An Automatic Baseline Regulation in a Highly Integrated Receiver Chip for JUNO

    Science.gov (United States)

    Muralidharan, P.; Zambanini, A.; Karagounis, M.; Grewing, C.; Liebau, D.; Nielinger, D.; Robens, M.; Kruth, A.; Peters, C.; Parkalian, N.; Yegin, U.; van Waasen, S.

    2017-09-01

    This paper describes the data processing unit and an automatic baseline regulation of a highly integrated readout chip (Vulcan) for JUNO. The chip collects data continuously at 1 Gsamples/sec. The Primary data processing which is performed in the integrated circuit can aid to reduce the memory and data processing efforts in the subsequent stages. In addition, a baseline regulator compensating a shift in the baseline is described.

  17. Stability analysis of geomagnetic baseline data obtained at Cheongyang observatory in Korea

    Science.gov (United States)

    Amran, Shakirah M.; Kim, Wan-Seop; Cho, Heh Ree; Park, Po Gyu

    2017-07-01

    The stability of baselines produced by Cheongyang (CYG) observatory from the period of 2014 to 2016 is analysed. Step heights of higher than 5 nT were found in H and Z components in 2014 and 2015 due to magnetic noise in the absolute-measurement hut. In addition, a periodic modulation behaviour observed in the H and Z baseline curves was related to annual temperature variation of about 20 °C in the fluxgate magnetometer hut. Improvement in data quality was evidenced by a small dispersion between successive measurements from June 2015 to the end of 2016. Moreover, the baseline was also improved by correcting the discontinuity in the H and Z baselines.

  18. Stability analysis of geomagnetic baseline data obtained at Cheongyang observatory in Korea

    Directory of Open Access Journals (Sweden)

    S. M. Amran

    2017-07-01

    Full Text Available The stability of baselines produced by Cheongyang (CYG observatory from the period of 2014 to 2016 is analysed. Step heights of higher than 5 nT were found in H and Z components in 2014 and 2015 due to magnetic noise in the absolute-measurement hut. In addition, a periodic modulation behaviour observed in the H and Z baseline curves was related to annual temperature variation of about 20 °C in the fluxgate magnetometer hut. Improvement in data quality was evidenced by a small dispersion between successive measurements from June 2015 to the end of 2016. Moreover, the baseline was also improved by correcting the discontinuity in the H and Z baselines.

  19. Protein malnutrition blunts the increment of taurine transporter expression by a high-fat diet and impairs taurine reestablishment of insulin secretion.

    Science.gov (United States)

    Branco, Renato Chaves Souto; Camargo, Rafael Ludemann; Batista, Thiago Martins; Vettorazzi, Jean Franciesco; Borck, Patrícia Cristine; Dos Santos-Silva, Junia Carolina Rebelo; Boschero, Antonio Carlos; Zoppi, Cláudio Cesar; Carneiro, Everardo Magalhães

    2017-09-01

    Taurine (Tau) restores β-cell function in obesity; however, its action is lost in malnourished obese rodents. Here, we investigated the mechanisms involved in the lack of effects of Tau in this model. C57BL/6 mice were fed a control diet (CD) (14% protein) or a protein-restricted diet (RD) (6% protein) for 6 wk. Afterward, mice received a high-fat diet (HFD) for 8 wk [CD + HFD (CH) and RD + HFD (RH)] with or without 5% Tau supplementation after weaning on their drinking water [CH + Tau (CHT) and RH + Tau (RHT)]. The HFD increased insulin secretion through mitochondrial metabolism in CH and RH. Tau prevented all those alterations in CHT only. The expression of the taurine transporter (Tau-T), as well as Tau content in pancreatic islets, was increased in CH but had no effect on RH. Protein malnutrition programs β cells and impairs Tau-induced restoration of mitochondrial metabolism and biogenesis. This may be associated with modulation of the expression of Tau-T in pancreatic islets, which may be responsible for the absence of effect of Tau in protein-malnourished obese mice.-Branco, R. C. S., Camargo, R. L., Batista, T. M., Vettorazzi, J. F., Borck, P. C., dos Santos-Silva, J. C. R., Boschero, A. C., Zoppi, C. C., Carneiro, E. M. Protein malnutrition blunts the increment of taurine transporter expression by a high-fat diet and impairs taurine reestablishment of insulin secretion. © FASEB.

  20. Corrective action baseline report for underground storage tank 2331-U Building 9201-1

    International Nuclear Information System (INIS)

    1994-01-01

    The purpose of this report is to provide baseline geochemical and hydrogeologic data relative to corrective action for underground storage tank (UST) 2331-U at the Building 9201-1 Site. Progress in support of the Building 9201-1 Site has included monitoring well installation and baseline groundwater sampling and analysis. This document represents the baseline report for corrective action at the Building 9201-1 site and is organized into three sections. Section 1 presents introductory information relative to the site, including the regulatory initiative, site description, and progress to date. Section 2 includes the summary of additional monitoring well installation activities and the results of baseline groundwater sampling. Section 3 presents the baseline hydrogeology and planned zone of influence for groundwater remediation

  1. 77 FR 28373 - Liberty Energy (Midstates) Corp.; Notice of Baseline Filing

    Science.gov (United States)

    2012-05-14

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR12-24-000] Liberty Energy (Midstates) Corp.; Notice of Baseline Filing Take notice that on April 30, 2012, Liberty Energy (Midstates) Corp. submitted a baseline filing of their Statement of Operating Conditions for services provided...

  2. Baseline asthma burden, comorbidities, and biomarkers in omalizumab-treated patients in PROSPERO.

    Science.gov (United States)

    Chipps, Bradley E; Zeiger, Robert S; Luskin, Allan T; Busse, William W; Trzaskoma, Benjamin L; Antonova, Evgeniya N; Pazwash, Hooman; Limb, Susan L; Solari, Paul G; Griffin, Noelle M; Casale, Thomas B

    2017-12-01

    Patients included in clinical trials do not necessarily reflect the real-world population. To understand the characteristics, including disease and comorbidity burden, of patients with asthma receiving omalizumab in a real-world setting. The Prospective Observational Study to Evaluate Predictors of Clinical Effectiveness in Response to Omalizumab (PROSPERO) was a US-based, multicenter, single-arm, and prospective study. Patients (≥12 years of age) with allergic asthma initiating omalizumab treatment based on physician-assessed need were included and followed for 12 months. Exacerbations, health care use, adverse events, and Asthma Control Test (ACT) scores were assessed monthly. Biomarkers (blood eosinophils, fractional exhaled nitric oxide, and periostin) were evaluated and patient-reported outcomes (Asthma Quality of Life Questionnaire for 12 Years and Older [AQLQ+12] and Work Productivity and Activity Impairment: Asthma questionnaire [WPAI:Asthma]) were completed at baseline and months 6 and 12. The Mini Rhinoconjunctivitis Quality of Life Questionnaire (MiniRQLQ) was completed at baseline and 12 months. Most of the 806 enrollees (91.4%) were adults (mean age 47.3 years, SD 17.4), white (70.3%), and female (63.5%). Allergic comorbidity was frequently reported (84.2%), as were hypertension (35.5%) and depression (22.1%). In the 12 months before study entry, 22.1% of patients reported at least 1 asthma-related hospitalization, 60.7% reported at least 2 exacerbations, and 83.3% reported ACT scores no higher than 19 (uncontrolled asthma). Most patients had low biomarker levels based on prespecified cut-points. Baseline mean patient-reported outcome scores were 4.0 (SD 1.4) for AQLQ+12, 2.7 (SD 1.4) for MiniRQLQ, and 47.7 (SD 28.9) for WPAI:Asthma percentage of activity impairment and 33.5 (SD 28.7) for percentage of overall work impairment. The population initiating omalizumab in PROSPERO reported poorly controlled asthma and a substantial disease burden. Clinical

  3. Change Analysis in Structural Laser Scanning Point Clouds: The Baseline Method.

    Science.gov (United States)

    Shen, Yueqian; Lindenbergh, Roderik; Wang, Jinhu

    2016-12-24

    A method is introduced for detecting changes from point clouds that avoids registration. For many applications, changes are detected between two scans of the same scene obtained at different times. Traditionally, these scans are aligned to a common coordinate system having the disadvantage that this registration step introduces additional errors. In addition, registration requires stable targets or features. To avoid these issues, we propose a change detection method based on so-called baselines. Baselines connect feature points within one scan. To analyze changes, baselines connecting corresponding points in two scans are compared. As feature points either targets or virtual points corresponding to some reconstructable feature in the scene are used. The new method is implemented on two scans sampling a masonry laboratory building before and after seismic testing, that resulted in damages in the order of several centimeters. The centres of the bricks of the laboratory building are automatically extracted to serve as virtual points. Baselines connecting virtual points and/or target points are extracted and compared with respect to a suitable structural coordinate system. Changes detected from the baseline analysis are compared to a traditional cloud to cloud change analysis demonstrating the potential of the new method for structural analysis.

  4. Change Analysis in Structural Laser Scanning Point Clouds: The Baseline Method

    Directory of Open Access Journals (Sweden)

    Yueqian Shen

    2016-12-01

    Full Text Available A method is introduced for detecting changes from point clouds that avoids registration. For many applications, changes are detected between two scans of the same scene obtained at different times. Traditionally, these scans are aligned to a common coordinate system having the disadvantage that this registration step introduces additional errors. In addition, registration requires stable targets or features. To avoid these issues, we propose a change detection method based on so-called baselines. Baselines connect feature points within one scan. To analyze changes, baselines connecting corresponding points in two scans are compared. As feature points either targets or virtual points corresponding to some reconstructable feature in the scene are used. The new method is implemented on two scans sampling a masonry laboratory building before and after seismic testing, that resulted in damages in the order of several centimeters. The centres of the bricks of the laboratory building are automatically extracted to serve as virtual points. Baselines connecting virtual points and/or target points are extracted and compared with respect to a suitable structural coordinate system. Changes detected from the baseline analysis are compared to a traditional cloud to cloud change analysis demonstrating the potential of the new method for structural analysis.

  5. Policy implications of the GRI baseline projection of U.S. energy supply and demand to 2010, 1992

    International Nuclear Information System (INIS)

    1992-01-01

    The 1992 Edition of the GRI Baseline Projection of U.S. Energy Supply and Demand is summarized. Three broad implications concerning the future of the natural gas industry are highlighted: the residual impact of the August 1990 Gulf War on crude oil prices and the factors influencing the long-term price path, the impact of the growing number of environmental constraints on future energy use, and the effect of recent developments in gas production on future gas supply and price

  6. 75 FR 70732 - Enterprise Texas Pipeline LLC; Notice of Baseline Filing

    Science.gov (United States)

    2010-11-18

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-92-001] Enterprise Texas Pipeline LLC; Notice of Baseline Filing November 10, 2010. Take notice that on November 9, 2010, Enterprise Texas Pipeline LLC submitted a revised baseline filing of its Statement of Operating Conditions...

  7. System maintenance test plan for the TWRS controlled baseline database system

    International Nuclear Information System (INIS)

    Spencer, S.G.

    1998-01-01

    TWRS [Tank Waste Remediation System] Controlled Baseline Database, formally known as the Performance Measurement Control System, is used to track and monitor TWRS project management baseline information. This document contains the maintenance testing approach for software testing of the TCBD system once SCR/PRs are implemented

  8. 40 CFR 80.290 - How does a refiner apply for a sulfur baseline?

    Science.gov (United States)

    2010-07-01

    ... baseline? 80.290 Section 80.290 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... (abt) Program-General Information § 80.290 How does a refiner apply for a sulfur baseline? (a) The... accordance with § 80.217. (b) The sulfur baseline request must be sent to: U.S. EPA, Attn: Sulfur Program...

  9. Baseline inventory data recommendations for National Wildlife Refuges

    Data.gov (United States)

    Department of the Interior — The Baseline Inventory Team recommends that each refuge have available abiotic “data layers” for topography, aerial photography, hydrography, soils, boundaries, and...

  10. Baseline for trust: defining 'new and additional' climate funding

    Energy Technology Data Exchange (ETDEWEB)

    Stadelmann, Martin [University of Zurich (Switzerland); Roberts, J. Timmons [Brown University (United States); Huq, Saleemul

    2010-06-15

    Climate finance is becoming a dark curve on the road from Copenhagen to Cancún. Poorer nations fear that richer ones will fulfil the US$30 billion 'fast-start' climate finance promises made in the non-binding Copenhagen Accord by relabelling or diverting basic development aid, or by simply delivering on past climate finance pledges. The problem is simple: contributor countries are operating with no clear baseline against which their promise of 'new and additional' funding can be counted – and they do not accept the baselines put forth by developing countries. A viable solution for the short term is to use projections of business-as-usual development assistance as baselines. The longer-term benchmark could be the provision of truly 'new' funds from new funding sources. Substantial up-front negotiations may be required, but seizing this opportunity to define baselines will build confidence on both sides and create predictability for future finance.

  11. Office of Civilian Radioactive Waste Management Program Cost and Schedule Baseline

    International Nuclear Information System (INIS)

    1992-09-01

    The purpose of this document is to establish quantitative expressions of proposed costs and schedule to serve as a basis for measurement of program performance. It identifies the components of the Program Cost and Schedule Baseline (PCSB) that will be subject to change control by the Executive (Level 0) and Program (Level 1) Change Control Boards (CCBS) and establishes their baseline values. This document also details PCSB reporting, monitoring, and corrective action requirements. The Program technical baseline contained in the Waste Management System Description (WMSD), the Waste Management System Requirements (WMSR), and the Physical System Requirements documents provide the technical basis for the PCSB. Changes to the PCSB will be approved by the Pregrain Change Control Board (PCCB)In addition to the PCCB, the Energy System Acquisition Advisory Board Baseline CCB (ESAAB BCCB) will perform control functions relating to Total Project Cost (TPC) and major schedule milestones for the Yucca Mountain Site Characterization Project and the Monitored Retrievable Storage (MRS) Project

  12. Predicting Baseline for Analysis of Electricity Pricing

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T. [Ulsan National Inst. of Science and Technology (Korea, Republic of); Lee, D. [Ulsan National Inst. of Science and Technology (Korea, Republic of); Choi, J. [Ulsan National Inst. of Science and Technology (Korea, Republic of); Spurlock, A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sim, A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Todd, A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wu, K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-05-03

    To understand the impact of new pricing structure on residential electricity demands, we need a baseline model that captures every factor other than the new price. The standard baseline is a randomized control group, however, a good control group is hard to design. This motivates us to devlop data-driven approaches. We explored many techniques and designed a strategy, named LTAP, that could predict the hourly usage years ahead. The key challenge in this process is that the daily cycle of electricity demand peaks a few hours after the temperature reaching its peak. Existing methods rely on the lagged variables of recent past usages to enforce this daily cycle. These methods have trouble making predictions years ahead. LTAP avoids this trouble by assuming the daily usage profile is determined by temperature and other factors. In a comparison against a well-designed control group, LTAP is found to produce accurate predictions.

  13. CASA Uno GPS orbit and baseline experiments

    Science.gov (United States)

    Schutz, B. E.; Ho, C. S.; Abusali, P. A. M.; Tapley, B. D.

    1990-01-01

    CASA Uno data from sites distributed in longitude from Australia to Europe have been used to determine orbits of the GPS satellites. The characteristics of the orbits determined from double difference phase have been evaluated through comparisons of two-week solutions with one-week solutions and by comparisons of predicted and estimated orbits. Evidence of unmodeled effects is demonstrated, particularly associated with the orbit planes that experience solar eclipse. The orbit accuracy has been assessed through the repeatability of unconstrained estimated baseline vectors ranging from 245 km to 5400 km. Both the baseline repeatability and the comparison with independent space geodetic methods give results at the level of 1-2 parts in 100,000,000. In addition, the Mojave/Owens Valley (245 km) and Kokee Park/Ft. Davis (5409 km) estimates agree with VLBI and SLR to better than 1 part in 100,000,000.

  14. Development Of Regional Climate Mitigation Baseline For A DominantAgro-Ecological Zone Of Karnataka, India

    Energy Technology Data Exchange (ETDEWEB)

    Sudha, P.; Shubhashree, D.; Khan, H.; Hedge, G.T.; Murthy, I.K.; Shreedhara, V.; Ravindranath, N.H.

    2007-06-01

    Setting a baseline for carbon stock changes in forest andland use sector mitigation projects is an essential step for assessingadditionality of the project. There are two approaches for settingbaselines namely, project-specific and regional baseline. This paperpresents the methodology adopted for estimating the land available formitigation, for developing a regional baseline, transaction cost involvedand a comparison of project-specific and regional baseline. The studyshowed that it is possible to estimate the potential land and itssuitability for afforestation and reforestation mitigation projects,using existing maps and data, in the dry zone of Karnataka, southernIndia. The study adopted a three-step approach for developing a regionalbaseline, namely: i) identification of likely baseline options for landuse, ii) estimation of baseline rates of land-use change, and iii)quantification of baseline carbon profile over time. The analysis showedthat carbon stock estimates made for wastelands and fallow lands forproject-specific as well as the regional baseline are comparable. Theratio of wasteland Carbon stocks of a project to regional baseline is1.02, and that of fallow lands in the project to regional baseline is0.97. The cost of conducting field studies for determination of regionalbaseline is about a quarter of the cost of developing a project-specificbaseline on a per hectare basis. The study has shown the reliability,feasibility and cost-effectiveness of adopting regional baseline forforestry sectormitigation projects.

  15. 75 FR 38802 - DCP Raptor Pipeline, LLC; Notice of Baseline Filing

    Science.gov (United States)

    2010-07-06

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-42-000] DCP Raptor Pipeline, LLC; Notice of Baseline Filing June 28, 2010. Take notice that on June 22, 2010, DCP Raptor Pipeline, LLC submitted a baseline filing of its Statement of Operating Conditions for services provided...

  16. Mass hierarchy sensitivity of medium baseline reactor neutrino experiments with multiple detectors

    Directory of Open Access Journals (Sweden)

    Hong-Xin Wang

    2017-05-01

    Full Text Available We report the neutrino mass hierarchy (MH determination of medium baseline reactor neutrino experiments with multiple detectors, where the sensitivity of measuring the MH can be significantly improved by adding a near detector. Then the impact of the baseline and target mass of the near detector on the combined MH sensitivity has been studied thoroughly. The optimal selections of the baseline and target mass of the near detector are ∼12.5 km and ∼4 kton respectively for a far detector with the target mass of 20 kton and the baseline of 52.5 km. As typical examples of future medium baseline reactor neutrino experiments, the optimal location and target mass of the near detector are selected for the specific configurations of JUNO and RENO-50. Finally, we discuss distinct effects of the reactor antineutrino energy spectrum uncertainty for setups of a single detector and double detectors, which indicate that the spectrum uncertainty can be well constrained in the presence of the near detector.

  17. Guidance on Port Biological Baseline Surveys (PBBS)

    Digital Repository Service at National Institute of Oceanography (India)

    Awad, A.; Haag, F.; Anil, A.C.; Abdulla, A.

    This publication has been prepared by GBP, IOI, CSIR-NIO and IUCN in order to serve as guidance to those who are planning to carry out a port biological baseline survey, in particular in the context of Ballast Water Management. It has been drafted...

  18. Baseline and Multimodal UAV GCS Interface Design

    Science.gov (United States)

    2013-07-01

    complete a computerized version of the NASA - TLX assessment of perceived mental workload. 2.3 Results The baseline condition ran smoothly and with...System MALE Medium-altitude, Long-endurance NASA - TLX NASA Task Load Index SA Situation Awareness TDT Tucker Davis Technologies UAV Uninhabited Aerial

  19. 48 CFR 34.202 - Integrated Baseline Reviews.

    Science.gov (United States)

    2010-10-01

    ... or contractor, and the Government, of the— (1) Ability of the project's technical plan to achieve the... successfully achieve the project schedule objectives; (3) Ability of the Performance Measurement Baseline (PMB... SPECIAL CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION Earned Value Management System 34.202...

  20. Baseline glucocorticoids are drivers of body mass gain in a diving seabird.

    Science.gov (United States)

    Hennin, Holly L; Wells-Berlin, Alicia M; Love, Oliver P

    2016-03-01

    Life-history trade-offs are influenced by variation in individual state, with individuals in better condition often completing life-history stages with greater success. Although resource accrual significantly impacts key life-history decisions such as the timing of reproduction, little is known about the underlying mechanisms driving resource accumulation. Baseline corticosterone (CORT, the primary avian glucocorticoid) mediates daily and seasonal energetics, responds to changes in food availability, and has been linked to foraging behavior, making it a strong potential driver of individual variation in resource accrual and deposition. Working with a captive colony of white-winged scoters (Melanitta fusca deglandi), we aimed to causally determine whether variation in baseline CORT drives individual body mass gains mediated through fattening rate (plasma triglycerides corrected for body mass). We implanted individuals with each of three treatment pellets to elevate CORT within a baseline range in a randomized order: control, low dose of CORT, high dose of CORT, then blood sampled and recorded body mass over a two-week period to track changes in baseline CORT, body mass, and fattening rates. The high CORT treatment significantly elevated levels of plasma hormone for a short period of time within the biologically relevant, baseline range for this species, but importantly did not inhibit the function of the HPA (hypothalamic-pituitary-adrenal) axis. Furthermore, an elevation in baseline CORT resulted in a consistent increase in body mass throughout the trial period compared to controls. This is some of the first empirical evidence demonstrating that elevations of baseline CORT within a biologically relevant range have a causal, direct, and positive influence on changes in body mass.

  1. Baseline glucocorticoids are drivers of body mass gain in a diving seabird

    Science.gov (United States)

    Hennin, Holly; Berlin, Alicia; Love, Oliver P.

    2016-01-01

    Life-history trade-offs are influenced by variation in individual state, with individuals in better condition often completing life-history stages with greater success. Although resource accrual significantly impacts key life-history decisions such as the timing of reproduction, little is known about the underlying mechanisms driving resource accumulation. Baseline corticosterone (CORT, the primary avian glucocorticoid) mediates daily and seasonal energetics, responds to changes in food availability, and has been linked to foraging behavior, making it a strong potential driver of individual variation in resource accrual and deposition. Working with a captive colony of white-winged scoters (Melanitta fusca deglandi), we aimed to causally determine whether variation in baseline CORT drives individual body mass gains mediated through fattening rate (plasma triglycerides corrected for body mass). We implanted individuals with each of three treatment pellets to elevate CORT within a baseline range in a randomized order: control, low dose of CORT, high dose of CORT, then blood sampled and recorded body mass over a two-week period to track changes in baseline CORT, body mass, and fattening rates. The high CORT treatment significantly elevated levels of plasma hormone for a short period of time within the biologically relevant, baseline range for this species, but importantly did not inhibit the function of the HPA (hypothalamic–pituitary–adrenal) axis. Furthermore, an elevation in baseline CORT resulted in a consistent increase in body mass throughout the trial period compared to controls. This is some of the first empirical evidence demonstrating that elevations of baseline CORT within a biologically relevant range have a causal, direct, and positive influence on changes in body mass.

  2. Item response theory analysis of the mechanics baseline test

    Science.gov (United States)

    Cardamone, Caroline N.; Abbott, Jonathan E.; Rayyan, Saif; Seaton, Daniel T.; Pawl, Andrew; Pritchard, David E.

    2012-02-01

    Item response theory is useful in both the development and evaluation of assessments and in computing standardized measures of student performance. In item response theory, individual parameters (difficulty, discrimination) for each item or question are fit by item response models. These parameters provide a means for evaluating a test and offer a better measure of student skill than a raw test score, because each skill calculation considers not only the number of questions answered correctly, but the individual properties of all questions answered. Here, we present the results from an analysis of the Mechanics Baseline Test given at MIT during 2005-2010. Using the item parameters, we identify questions on the Mechanics Baseline Test that are not effective in discriminating between MIT students of different abilities. We show that a limited subset of the highest quality questions on the Mechanics Baseline Test returns accurate measures of student skill. We compare student skills as determined by item response theory to the more traditional measurement of the raw score and show that a comparable measure of learning gain can be computed.

  3. Information Technology Sector Baseline Risk Assessment

    Science.gov (United States)

    2009-08-01

    alternative root be economically advantageous , an actor’s ability to exploit market forces and create an alternative root would be significantly improved...conduct their operations. Therefore, a loss or disruption to Internet services would not be advantageous for the desired outcomes of these syndicates.26... eCommerce Service loss or disruption [C] Traffic Redirection [C] = Undesired consequence Information Technology Sector Baseline Risk Assessment

  4. The prognostic utility of baseline alpha-fetoprotein for hepatocellular carcinoma patients.

    Science.gov (United States)

    Silva, Jack P; Gorman, Richard A; Berger, Nicholas G; Tsai, Susan; Christians, Kathleen K; Clarke, Callisia N; Mogal, Harveshp; Gamblin, T Clark

    2017-12-01

    Alpha-fetoprotein (AFP) has a valuable role in postoperative surveillance for hepatocellular carcinoma (HCC) recurrence. The utility of pretreatment or baseline AFP remains controversial. The present study hypothesized that elevated baseline AFP levels are associated with worse overall survival in HCC patients. Adult HCC patients were identified using the National Cancer Database (2004-2013). Patients were stratified according to baseline AFP measurements into the following groups: Negative (2000). The primary outcome was overall survival (OS), which was analyzed by log-rank test and graphed using Kaplan-Meier method. Multivariate regression modeling was used to determine hazard ratios (HR) for OS. Of 41 107 patients identified, 15 809 (33.6%) were Negative. Median overall survival was highest in the Negative group, followed by Borderline, Elevated, and Highly Elevated (28.7 vs 18.9 vs 8.8 vs 3.2 months; P < 0.001). On multivariate analysis, overall survival hazard ratios for the Borderline, Elevated, and Highly Elevated groups were 1.18 (P = 0.267), 1.94 (P < 0.001), and 1.77 (P = 0.007), respectively (reference Negative). Baseline AFP independently predicted overall survival in HCC patients regardless of treatment plan. A baseline AFP value is a simple and effective method to assist in expected survival for HCC patients. © 2017 Wiley Periodicals, Inc.

  5. Effect of computer game playing on baseline laparoscopic simulator skills.

    Science.gov (United States)

    Halvorsen, Fredrik H; Cvancarova, Milada; Fosse, Erik; Mjåland, Odd

    2013-08-01

    Studies examining the possible association between computer game playing and laparoscopic performance in general have yielded conflicting results and neither has a relationship between computer game playing and baseline performance on laparoscopic simulators been established. The aim of this study was to examine the possible association between previous and present computer game playing and baseline performance on a virtual reality laparoscopic performance in a sample of potential future medical students. The participating students completed a questionnaire covering the weekly amount and type of computer game playing activity during the previous year and 3 years ago. They then performed 2 repetitions of 2 tasks ("gallbladder dissection" and "traverse tube") on a virtual reality laparoscopic simulator. Performance on the simulator were then analyzed for association to their computer game experience. Local high school, Norway. Forty-eight students from 2 high school classes volunteered to participate in the study. No association between prior and present computer game playing and baseline performance was found. The results were similar both for prior and present action game playing and prior and present computer game playing in general. Our results indicate that prior and present computer game playing may not affect baseline performance in a virtual reality simulator.

  6. Investigating the baselines of Bismuth, Optical Fiber and LED calibrated photomultiplier tubes

    CERN Document Server

    Evans, Hywel Turner

    2016-01-01

    LUCID is a detector that is the luminosity monitor for the ATLAS experiment, and its aim is to determine luminosity with an uncertainty of a few percent. The main purpose of this work is the study of the baseline stability of the LUCID readout channels during calibration runs. This study represents the first systematic approach of this problem performed by the LUCID group. By replacing the mean baseline with the minimum baseline of each event, an upper limit of 2.85% was placed upon possible improvement in determining the LED amplitude. It is therefore better to use a fixed baseline for LED, as pollution has been observed when calculating event by event. For Bismuth and Fiber, the improvement cannot be more than the gain stability of 1%, therefore the existing method is verified as optimal.

  7. On the feasibility of routine baseline improvement in processing of geomagnetic observatory data

    Science.gov (United States)

    Soloviev, Anatoly; Lesur, Vincent; Kudin, Dmitry

    2018-02-01

    We propose a new approach to the calculation of regular baselines at magnetic observatories. The proposed approach is based on the simultaneous analysis of the irregular absolute observations and the continuous time-series deltaF, widely used for estimating the data quality. The systematic deltaF analysis allows to take into account all available information about the operation of observatory instruments (i.e., continuous records of the field variations and its modulus) in the intervals between the times of absolute observations, as compared to the traditional baseline calculation where only spot values are considered. To establish a connection with the observed spot baseline values, we introduce a function for approximate evaluation of the intermediate baseline values. An important feature of the algorithm is its quantitative estimation of the resulting data precision and thus determination of the problematic fragments in raw data. We analyze the robustness of the algorithm operation using synthetic data sets. We also compare baselines and definitive data derived by the proposed algorithm with those derived by the traditional approach using Saint Petersburg observatory data, recorded in 2015 and accepted by INTERMAGNET. It is shown that the proposed method allows to essentially improve the resulting data quality when baseline data are not good enough. The obtained results prove that the baseline variability in time might be quite rapid.[Figure not available: see fulltext.

  8. Baseline Screening Mammography: Performance of Full-Field Digital Mammography Versus Digital Breast Tomosynthesis.

    Science.gov (United States)

    McDonald, Elizabeth S; McCarthy, Anne Marie; Akhtar, Amana L; Synnestvedt, Marie B; Schnall, Mitchell; Conant, Emily F

    2015-11-01

    Baseline mammography studies have significantly higher recall rates than mammography studies with available comparison examinations. Digital breast tomosynthesis reduces recalls when compared with digital mammographic screening alone, but many sites operate in a hybrid environment. To maximize the effect of screening digital breast tomosynthesis with limited resources, choosing which patient populations will benefit most is critical. This study evaluates digital breast tomosynthesis in the baseline screening population. Outcomes were compared for 10,728 women who underwent digital mammography screening, including 1204 (11.2%) baseline studies, and 15,571 women who underwent digital breast tomosynthesis screening, including 1859 (11.9%) baseline studies. Recall rates, cancer detection rates, and positive predictive values were calculated. Logistic regression estimated the odds ratios of recall for digital mammography versus digital breast tomosynthesis for patients undergoing baseline screening and previously screened patients, adjusted for age, race, and breast density. In the baseline subgroup, recall rates for digital mammography and digital breast tomosynthesis screening were 20.5% and 16.0%, respectively (p = 0.002); digital breast tomosynthesis screening in the baseline subgroup resulted in a 22% reduction in recall compared with digital mammography, or 45 fewer patients recalled per 1000 patients screened. Digital breast tomosynthesis screening in the previously screened patients resulted in recall reduction of 14.3% (p tomosynthesis than from digital mammography alone.

  9. Functional Testing Protocols for Commercial Building Efficiency Baseline Modeling Software

    Energy Technology Data Exchange (ETDEWEB)

    Jump, David; Price, Phillip N.; Granderson, Jessica; Sohn, Michael

    2013-09-06

    This document describes procedures for testing and validating proprietary baseline energy modeling software accuracy in predicting energy use over the period of interest, such as a month or a year. The procedures are designed according to the methodology used for public domain baselining software in another LBNL report that was (like the present report) prepared for Pacific Gas and Electric Company: ?Commercial Building Energy Baseline Modeling Software: Performance Metrics and Method Testing with Open Source Models and Implications for Proprietary Software Testing Protocols? (referred to here as the ?Model Analysis Report?). The test procedure focuses on the quality of the software?s predictions rather than on the specific algorithms used to predict energy use. In this way the software vendor is not required to divulge or share proprietary information about how their software works, while enabling stakeholders to assess its performance.

  10. Is CP violation observable in long baseline neutrino oscillation experiments?

    International Nuclear Information System (INIS)

    Tanimoto, M.

    1997-01-01

    We have studied CP violation originating from the phase of the neutrino-mixing matrix in the long baseline neutrino oscillation experiments. The direct measurement of CP violation is the difference of the transition probabilities between CP-conjugate channels. In those experiments, the CP-violating effect is not suppressed if the highest neutrino mass scale is taken to be 1 endash 5 eV, which is appropriate for the cosmological hot dark matter. Assuming the hierarchy for the neutrino masses, the upper bounds of CP violation have been calculated for three cases, in which mixings are constrained by the recent short baseline ones. The calculated upper bounds are larger than 10 -2 , which will be observable in the long baseline accelerator experiments. The matter effect, which is not CP invariant, has been also estimated in those experiments. copyright 1997 The American Physical Society

  11. Re-establishing dignity

    DEFF Research Database (Denmark)

    Høy, Bente; Hall, E.O.C

    2012-01-01

    appearance’. The study documents that caring for older people is about creating small everyday circumstances in which patient dignity can flourish. Shortcomings of a secondary analysis are discussed and suggestions for future research, such as how older hospital patients experience caring and dignity...

  12. Causality re-established.

    Science.gov (United States)

    D'Ariano, Giacomo Mauro

    2018-07-13

    Causality has never gained the status of a 'law' or 'principle' in physics. Some recent literature has even popularized the false idea that causality is a notion that should be banned from theory. Such misconception relies on an alleged universality of the reversibility of the laws of physics, based either on the determinism of classical theory, or on the multiverse interpretation of quantum theory, in both cases motivated by mere interpretational requirements for realism of the theory. Here, I will show that a properly defined unambiguous notion of causality is a theorem of quantum theory, which is also a falsifiable proposition of the theory. Such a notion of causality appeared in the literature within the framework of operational probabilistic theories. It is a genuinely theoretical notion, corresponding to establishing a definite partial order among events, in the same way as we do by using the future causal cone on Minkowski space. The notion of causality is logically completely independent of the misidentified concept of 'determinism', and, being a consequence of quantum theory, is ubiquitous in physics. In addition, as classical theory can be regarded as a restriction of quantum theory, causality holds also in the classical case, although the determinism of the theory trivializes it. I then conclude by arguing that causality naturally establishes an arrow of time. This implies that the scenario of the 'block Universe' and the connected 'past hypothesis' are incompatible with causality, and thus with quantum theory: they are both doomed to remain mere interpretations and, as such, are not falsifiable, similar to the hypothesis of 'super-determinism'.This article is part of a discussion meeting issue 'Foundations of quantum mechanics and their impact on contemporary society'. © 2018 The Author(s).

  13. Integrated Baseline Review (IBR) Handbook

    Science.gov (United States)

    Fleming, Jon F.; Terrell, Stefanie M.

    2018-01-01

    The purpose of this handbook is intended to be a how-to guide to prepare for, conduct, and close-out an Integrated Baseline Review (IBR). It discusses the steps that should be considered, describes roles and responsibilities, tips for tailoring the IBR based on risk, cost, and need for management insight, and provides lessons learned from past IBRs. Appendices contain example documentation typically used in connection with an IBR. Note that these appendices are examples only, and should be tailored to meet the needs of individual projects and contracts.

  14. Environmental Baseline File National Transportation

    International Nuclear Information System (INIS)

    Harris, M.

    1999-01-01

    This Environmental Baseline File summarizes and consolidates information related to the national-level transportation of commercial spent nuclear fuel. Topics addressed include: shipments of commercial spent nuclear fuel based on mostly truck and mostly rail shipping scenarios; transportation routing for commercial spent nuclear fuel sites and DOE sites; radionuclide inventories for various shipping container capacities; transportation routing; populations along transportation routes; urbanized area population densities; the impacts of historical, reasonably foreseeable, and general transportation; state-level food transfer factors; Federal Guidance Report No. 11 and 12 radionuclide dose conversion factors; and national average atmospheric conditions

  15. Steelhead Supplementation Studies in Idaho Rivers: To evaluate the feasibility of using artificial production to increase natural steelhead populations and to collect baseline life history, genetic, and disease data from natural steelhead populations. 1993 Annual report

    International Nuclear Information System (INIS)

    Byrne, A.

    1996-01-01

    The Steelhead Supplementation Study was designed to evaluate the feasibility of using artificial production to increase natural steelhead Oncorhynchus mykiss populations and to collect baseline life history, genetic, and disease data from natural steelhead populations. To evaluate supplementation, the authors focused their experimental design on post-release survival, reproductive success, long-term fitness, and ecological interactions. They began field experiments in 1993 by outplanting hatchery adults and fingerlings to assess reproductive fitness and long-term survival. They snorkeled eight streams to estimate juvenile steelhead densities, recorded temperatures in 17 streams, and tagged natural steelhead in six streams with Passive Integrated Transponder (PIT) tags

  16. The optimized baseline project: Reinventing environmental restoration at Hanford

    International Nuclear Information System (INIS)

    Goodenough, J.D.; Janaskie, M.T.; Kleinen, P.J.

    1994-01-01

    The U.S. Department of Energy Richland Operations Office (DOE-RL) is using a strategic planning effort (termed the Optimized Baseline Project) to develop a new approach to the Hanford Environmental Restoration program. This effort seeks to achieve a quantum leap improvement in performance through results oriented prioritization of activities. This effort was conducted in parallel with the renegotiation of the Tri-Party Agreement and provided DOE with an opportunity to propose innovative initiatives to promote cost effectiveness, accelerate progress in the Hanford Environmental Restoration Program and involve stakeholders in the decision-making process. The Optimized Baseline project is an innovative approach to program planning and decision-making in several respects. First, the process is a top down, value driven effort that responds to values held by DOE, the regulatory community and the public. Second, planning is conducted in a way that reinforces the technical management process at Richland, involves the regulatory community in substantive decisions, and includes the public. Third, the Optimized Baseline Project is being conducted as part of a sitewide Hanford initiative to reinvent Government. The planning process used for the Optimized Baseline Project has many potential applications at other sites and in other programs where there is a need to build consensus among diverse, independent groups of stakeholders and decisionmakers. The project has successfully developed and demonstrated an innovative approach to program planning that accelerates the pace of cleanup, involves the regulators as partners with DOE in priority setting, and builds public understanding and support for the program through meaningful opportunities for involvement

  17. Scheme for simultaneous generation of three-color ten GW-level X-ray pulses from baseline XFEL undulator and multi-user distribution system for XFEL laboratory

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2010-01-01

    The baseline design of present XFEL projects only considers the production of a single photon beam at fixed wavelength from each baseline undulator. At variance, the scheme described in this paper considers the simultaneous production of high intensity SASE FEL radiation at three different wavelengths. We present a feasibility study of our scheme, and we make exemplifications with parameters of the baseline SASE2 line of the European XFEL operating in simultaneous mode at 0.05 nm, 0.15 nm and 0.4 nm. Our technique for generating the two colors at 0.05 nm and 0.15 nm is based in essence on a ''fresh bunch'' technique. For the generation of radiation at 0.4 nm we propose to use an ''afterburner'' technique. Implementation of these techniques does not perturb the baseline mode of operation of the SASE2 undulator. The present paper also describes an efficient way to obtain a multi-user facility. It is shown that, although the XFEL photon beam from a given undulator is meant for a single user, movable multilayer X-ray mirrors can be used to serve many users simultaneously. The proposed photon beam distribution system would allow to switch the FEL beam quickly between many experiments in order to make an efficient use of the source. Distribution of photons is achieved on the basis of pulse trains and it is possible to distribute the multicolor photon beam among many independent beam lines, thereby enabling many users to work in parallel with different wavelengths. (orig.)

  18. Baseline neurocognitive testing in sports-related concussions: the importance of a prior night's sleep.

    Science.gov (United States)

    McClure, D Jake; Zuckerman, Scott L; Kutscher, Scott J; Gregory, Andrew J; Solomon, Gary S

    2014-02-01

    The management of sports-related concussions (SRCs) utilizes serial neurocognitive assessments and self-reported symptom inventories to assess recovery and safety for return to play (RTP). Because postconcussive RTP goals include symptom resolution and a return to neurocognitive baseline levels, clinical decisions rest in part on understanding modifiers of this baseline. Several studies have reported age and sex to influence baseline neurocognitive performance, but few have assessed the potential effect of sleep. We chose to investigate the effect of reported sleep duration on baseline Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) performance and the number of patient-reported symptoms. We hypothesized that athletes receiving less sleep before baseline testing would perform worse on neurocognitive metrics and report more symptoms. Cross-sectional study; Level of evidence, 3. We retrospectively reviewed 3686 nonconcussed athletes (2371 male, 1315 female; 3305 high school, 381 college) with baseline symptom and ImPACT neurocognitive scores. Patients were stratified into 3 groups based on self-reported sleep duration the night before testing: (1) short, sleep duration on baseline ImPACT performance. A univariate ANCOVA was performed to investigate the influence of sleep on total self-reported symptoms. When controlling for age and sex as covariates, the MANCOVA revealed significant group differences on ImPACT reaction time, verbal memory, and visual memory scores but not visual-motor (processing) speed scores. An ANCOVA also revealed significant group differences in total reported symptoms. For baseline symptoms and ImPACT scores, subsequent pairwise comparisons revealed these associations to be most significant when comparing the short and intermediate sleep groups. Our results indicate that athletes sleeping fewer than 7 hours before baseline testing perform worse on 3 of 4 ImPACT scores and report more symptoms. Because SRC management and RTP

  19. Carbon intensity of electricity generation and CDM baseline: case studies of three Chinese provinces

    International Nuclear Information System (INIS)

    Zhang Chi; Heller, T.C.; May, M.M.

    2005-01-01

    A difficult and persistent issue in the discussion of Clean Development Mechanism is estimating a carbon emissions baseline, against which tradable permits may be certified. This paper examines the proposition of adopting sectoral, as opposed to project level, baselines by conducting case studies of the electricity industry in three Chinese provinces. We find that complicated central planning, financial and institutional factors have been behind the declining trend of carbon intensity in electricity generation and its provincial variations. Government planned electricity development which incorporates many of these factors and the associated industry carbon intensity may serve as a second best baseline. However, the limitation of the baseline we examine in this study plus difficulties numerous studies have revealed in baseline setting suggests that using baselines based on counterfactuals of what would happen will in the end either miss good emission reduction opportunities, or compromise the integrity of the regime

  20. Toward Baseline Software Anomalies in NASA Missions

    Science.gov (United States)

    Layman, Lucas; Zelkowitz, Marvin; Basili, Victor; Nikora, Allen P.

    2012-01-01

    In this fast abstract, we provide preliminary findings an analysis of 14,500 spacecraft anomalies from unmanned NASA missions. We provide some baselines for the distributions of software vs. non-software anomalies in spaceflight systems, the risk ratings of software anomalies, and the corrective actions associated with software anomalies.

  1. Detecting CP violation in a single neutrino oscillation channel at very long baselines

    International Nuclear Information System (INIS)

    Latimer, D. C.; Escamilla, J.; Ernst, D. J.

    2007-01-01

    We propose a way of detecting CP violation in a single neutrino oscillation channel at very long baselines (on the order of several thousands of kilometers), given precise knowledge of the smallest mass-squared difference. It is shown that CP violation can be characterized by a shift in L/E of the peak oscillation in the ν e -ν μ appearance channel, both in vacuum and in matter. In fact, matter effects enhance the shift at a fixed energy. We consider the case in which sub-GeV neutrinos are measured with varying baseline and also the case of a fixed baseline. For the varied baseline, accurate knowledge of the absolute neutrino flux would not be necessary; however, neutrinos must be distinguishable from antineutrinos. For the fixed baseline, it is shown that CP violation can be distinguished if the mixing angle θ 13 were known

  2. Productivity, Performance and Return on Investment: A Baseline Analysis of Tennessee Public Institutions of Higher Education

    Science.gov (United States)

    Tennessee Higher Education Commission, 2010

    2010-01-01

    Tennessee needs to continuously increase its degree productivity by four percent every year from now until 2025. In the midst of this need for increased degree production, the state's current economic realities indicate public institutions will receive little to no new state appropriated revenues for the foreseeable future. The Master Plan Annual…

  3. Pipeline integrity: ILI baseline data for QRA

    Energy Technology Data Exchange (ETDEWEB)

    Porter, Todd R. [Tuboscope Pipeline Services, Houston, TX (United States)]. E-mail: tporter@varco.com; Silva, Jose Augusto Pereira da [Pipeway Engenharia, Rio de Janeiro, RJ (Brazil)]. E-mail: guto@pipeway.com; Marr, James [MARR and Associates, Calgary, AB (Canada)]. E-mail: jmarr@marr-associates.com

    2003-07-01

    The initial phase of a pipeline integrity management program (IMP) is conducting a baseline assessment of the pipeline system and segments as part of Quantitative Risk Assessment (QRA). This gives the operator's integrity team the opportunity to identify critical areas and deficiencies in the protection, maintenance, and mitigation strategies. As a part of data gathering and integration of a wide variety of sources, in-line inspection (ILI) data is a key element. In order to move forward in the integrity program development and execution, the baseline geometry of the pipeline must be determined with accuracy and confidence. From this, all subsequent analysis and conclusions will be derived. Tuboscope Pipeline Services (TPS), in conjunction with Pipeway Engenharia of Brazil, operate ILI inertial navigation system (INS) and Caliper geometry tools, to address this integrity requirement. This INS and Caliper ILI tool data provides pipeline trajectory at centimeter level resolution and sub-metre 3D position accuracy along with internal geometry - ovality, dents, misalignment, and wrinkle/buckle characterization. Global strain can be derived from precise INS curvature measurements and departure from the initial pipeline state. Accurate pipeline elevation profile data is essential in the identification of sag/over bend sections for fluid dynamic and hydrostatic calculations. This data, along with pipeline construction, operations, direct assessment and maintenance data is integrated in LinaViewPRO{sup TM}, a pipeline data management system for decision support functions, and subsequent QRA operations. This technology provides the baseline for an informed, accurate and confident integrity management program. This paper/presentation will detail these aspects of an effective IMP, and experience will be presented, showing the benefits for liquid and gas pipeline systems. (author)

  4. Evidence for the re-establishment of a heterogeneity in radiosensitivity among spermatogonial stem cells repopulating the mouse testis following depletion by X-rays

    International Nuclear Information System (INIS)

    Cattanach, B.M.; Barlow, J.H.

    1984-01-01

    Earlier studies have shown that the spermatogonial stem cells of the mouse testis recovering from previous radiation or chemical mutagen exposure give subnormal yields of genetic damage with subsequent X-irradiation. This response has been investigated further: (a) with a high, 9-Gy X-ray dose given 4, 12 or 21 days after a 1-Gy conditioning dose and (b) with a 1 + 7-Gy, 24-h fractionation regime given 4 or 14 days after a 1-Gy conditioning dose. The results of the experiments suggest that a heterogeneity in radiosensitivity, such as exists in unirradiated stem cell populations and absent 24-48 h after radiation depletion, is quickly re-established among the stem cells repopulating the testis. And that the newly established heterogeneity is removed by the second 1-Gy conditioning dose. With longer intervals between treatments, genetic yields consistent with additivity were obtained in Expt. 1; less clear results were obtained in Expt. 2. Comparison with earlier data generally suggested that the duration of the repopulating period is dose-dependent. In a third experiment evidence was obtained that genetic damage induced by X-irradiation can be reduced by a subsequent treatment with triethylenemelamine (TEM) during the repopulating phase. This confirmed an earlier finding. Such an interaction could not be demonstrated with two X-ray treatments. An explanation for the X-ray/TEM interaction is offered. (Auth.)

  5. Capabilities of long-baseline experiments in the presence of a sterile neutrino

    International Nuclear Information System (INIS)

    Dutta, Debajyoti; Gandhi, Raj; Kayser, Boris; Masud, Mehedi; Prakash, Suprabh

    2016-01-01

    Assuming that there is a sterile neutrino, we ask what then is the ability of long-baseline experiments to i) establish that neutrino oscillation violates CP, ii) determine the three-neutrino mass ordering, and iii) determine which CP-violating phase or phases are the cause of any CP violation that may be observed. We find that the ability to establish CP violation and to determine the mass ordering could be very substantial. However, the effects of the sterile neutrino could be quite large, and it might prove very difficult to determine which phase is responsible for an observed CP violation. We explain why a sterile neutrino changes the long-baseline sensitivities to CP violation and to the mass ordering in the ways that it does. We note that long-baseline experiments can probe the presence of sterile neutrinos in a way that is different from, and complementary to, the probes of short-baseline experiments. We explore the question of how large sterile-active mixing angles need to be before long-baseline experiments can detect their effects, or how small they need to be before the interpretation of these experiments can safely disregard the possible existence of sterile neutrinos.

  6. Baseline recommendations for greenhouse gas mitigation projects in the electric power sector

    Energy Technology Data Exchange (ETDEWEB)

    Kartha, Sivan; Lazarus, Michael [Stockholm Environment Institute/Tellus Institute, Boston, MA (United States); Bosi, Martina [International Energy Agency, Paris, 75 (France)

    2004-03-01

    The success of the Clean Development Mechanism (CDM) and other credit-based emission trading regimes depends on effective methodologies for quantifying a project's emissions reductions. The key methodological challenge lies in estimating project's counterfactual emission baseline, through balancing the need for accuracy, transparency, and practicality. Baseline standardisation (e.g. methodology, parameters and/or emission rate) can be a means to achieve these goals. This paper compares specific options for developing standardised baselines for the electricity sector - a natural starting point for baseline standardisation given the magnitude of the emissions reductions opportunities. The authors review fundamental assumptions that baseline studies have made with respect to estimating the generation sources avoided by CDM or other emission-reducing projects. Typically, studies have assumed that such projects affect either the operation of existing power plants (the operating margin) or the construction of new generation facilities (the build margin). The authors show that both effects are important to consider and thus recommend a combined margin approach for most projects, based on grid-specific data. They propose a three-category framework, according to projects' relative scale and environmental risk. (Author)

  7. Study on judgement baseline for XRF on-line detection system

    International Nuclear Information System (INIS)

    Zhang Quanshi; Bao Min

    2000-01-01

    Based on the Signal Detection Theory (SDT) and the statistics principle, the choice method of judgement baseline was studied. According to the characteristics of X-ray Fluorescence (XRF) spectra in the on-line detection system, the calculation methods for the characteristic peak of the element-tagged and background were carried out. The complex judgement baseline were rationally selected after a lot of experiments and analyzing. The operating results of near one year show that it is available

  8. Baseline Evaluations to Support Control Room Modernization at Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Boring, Ronald L.; Joe, Jeffrey C.

    2015-02-01

    For any major control room modernization activity at a commercial nuclear power plant (NPP) in the U.S., a utility should carefully follow the four phases prescribed by the U.S. Nuclear Regulatory Commission in NUREG-0711, Human Factors Engineering Program Review Model. These four phases include Planning and Analysis, Design, Verification and Validation, and Implementation and Operation. While NUREG-0711 is a useful guideline, it is written primarily from the perspective of regulatory review, and it therefore does not provide a nuanced account of many of the steps the utility might undertake as part of control room modernization. The guideline is largely summative—intended to catalog final products—rather than formative—intended to guide the overall modernization process. In this paper, we highlight two crucial formative sub-elements of the Planning and Analysis phase specific to control room modernization that are not covered in NUREG-0711. These two sub-elements are the usability and ergonomics baseline evaluations. A baseline evaluation entails evaluating the system as-built and currently in use. The usability baseline evaluation provides key insights into operator performance using the control system currently in place. The ergonomics baseline evaluation identifies possible deficiencies in the physical configuration of the control system. Both baseline evaluations feed into the design of the replacement system and subsequent summative benchmarking activities that help ensure that control room modernization represents a successful evolution of the control system.

  9. Baseline Evaluations to Support Control Room Modernization at Nuclear Power Plants

    International Nuclear Information System (INIS)

    Boring, Ronald L.; Joe, Jeffrey C.

    2015-01-01

    For any major control room modernization activity at a commercial nuclear power plant (NPP) in the U.S., a utility should carefully follow the four phases prescribed by the U.S. Nuclear Regulatory Commission in NUREG-0711, Human Factors Engineering Program Review Model. These four phases include Planning and Analysis, Design, Verification and Validation, and Implementation and Operation. While NUREG-0711 is a useful guideline, it is written primarily from the perspective of regulatory review, and it therefore does not provide a nuanced account of many of the steps the utility might undertake as part of control room modernization. The guideline is largely summative–intended to catalog final products–rather than formative–intended to guide the overall modernization process. In this paper, we highlight two crucial formative sub-elements of the Planning and Analysis phase specific to control room modernization that are not covered in NUREG-0711. These two sub-elements are the usability and ergonomics baseline evaluations. A baseline evaluation entails evaluating the system as-built and currently in use. The usability baseline evaluation provides key insights into operator performance using the control system currently in place. The ergonomics baseline evaluation identifies possible deficiencies in the physical configuration of the control system. Both baseline evaluations feed into the design of the replacement system and subsequent summative benchmarking activities that help ensure that control room modernization represents a successful evolution of the control system.

  10. Effect of Enamel Caries Lesion Baseline Severity on Fluoride Dose-Response

    Directory of Open Access Journals (Sweden)

    Frank Lippert

    2017-01-01

    Full Text Available This study aimed to investigate the effect of enamel caries lesion baseline severity on fluoride dose-response under pH cycling conditions. Early caries lesions were created in human enamel specimens at four different severities (8, 16, 24, and 36 h. Lesions were allocated to treatment groups (0, 83, and 367 ppm fluoride as sodium fluoride based on Vickers surface microhardness (VHN and pH cycled for 5 d. The cycling model comprised 3 × 1 min fluoride treatments sandwiched between 2 × 60 min demineralization challenges with specimens stored in artificial saliva in between. VHN was measured again and changes versus lesion baseline were calculated (ΔVHN. Data were analyzed using two-way ANOVA (p<0.05. Increased demineralization times led to increased surface softening. The lesion severity×fluoride concentration interaction was significant (p<0.001. Fluoride dose-response was observed in all groups. Lesions initially demineralized for 16 and 8 h showed similar overall rehardening (ΔVHN and more than 24 and 36 h lesions, which were similar. The 8 h lesions showed the greatest fluoride response differential (367 versus 0 ppm F which diminished with increasing lesion baseline severity. The extent of rehardening as a result of the 0 ppm F treatment increased with increasing lesion baseline severity, whereas it decreased for the fluoride treatments. In conclusion, lesion baseline severity impacts the extent of the fluoride dose-response.

  11. GNSS Single Frequency, Single Epoch Reliable Attitude Determination Method with Baseline Vector Constraint

    Directory of Open Access Journals (Sweden)

    Ang Gong

    2015-12-01

    Full Text Available For Global Navigation Satellite System (GNSS single frequency, single epoch attitude determination, this paper proposes a new reliable method with baseline vector constraint. First, prior knowledge of baseline length, heading, and pitch obtained from other navigation equipment or sensors are used to reconstruct objective function rigorously. Then, searching strategy is improved. It substitutes gradually Enlarged ellipsoidal search space for non-ellipsoidal search space to ensure correct ambiguity candidates are within it and make the searching process directly be carried out by least squares ambiguity decorrelation algorithm (LAMBDA method. For all vector candidates, some ones are further eliminated by derived approximate inequality, which accelerates the searching process. Experimental results show that compared to traditional method with only baseline length constraint, this new method can utilize a priori baseline three-dimensional knowledge to fix ambiguity reliably and achieve a high success rate. Experimental tests also verify it is not very sensitive to baseline vector error and can perform robustly when angular error is not great.

  12. Site Outcomes Baseline Multi Year Work Plan Volume 1, River Corridor Restoration Baseline

    International Nuclear Information System (INIS)

    Wintczak, T.M.

    2001-01-01

    The River Corridor Restoration volume is a compilation of Hanford Site scope, which excludes the approximately 194 km 2 Central Plateau. The River Corridor scope is currently contractually assigned to Fluor Hanford, Bechtel Hanford, inc., DynCorp, and Pacific Northwest National Laboratory, and others. The purpose of this project specification is to provide an overall scoping document for the River Corridor Restoration volume, and to provide a link with the overall Hanford Site River Corridor scope. Additionally, this specification provides an integrated and consolidated source of information for the various scopes, by current contract, for the River Corridor Restoration Baseline. It identifies the vision, mission, and goals, as well as the operational history of the Hanford Site, along with environmental setting and hazards

  13. Idaho National Laboratory’s Greenhouse Gas FY08 Baseline

    Energy Technology Data Exchange (ETDEWEB)

    Jennifer D. Morton

    2011-06-01

    A greenhouse gas (GHG) inventory is a systematic attempt to account for the production and release of certain gasses generated by an institution from various emission sources. The gasses of interest are those which have become identified by climate science as related to anthropogenic global climate change. This document presents an inventory of GHGs generated during fiscal year (FY) 2008 by Idaho National Laboratory (INL), a Department of Energy (DOE)-sponsored entity, located in southeastern Idaho. Concern about the environmental impact of GHGs has grown in recent years. This, together with a desire to decrease harmful environmental impacts, would be enough to encourage the calculation of a baseline estimate of total GHGs generated at INL. Additionally, INL has a desire to see how its emissions compare with similar institutions, including other DOE national laboratories. Executive Order 13514 requires that federal agencies and institutions document reductions in GHG emissions in the future, and such documentation will require knowledge of a baseline against which reductions can be measured. INL's FY08 GHG inventory was calculated according to methodologies identified in federal GHG guidance documents using operational control boundaries. It measures emissions generated in three Scopes: (1) INL emissions produced directly by stationary or mobile combustion and by fugitive emissions, (2) the share of emissions generated by entities from which INL purchased electrical power, and (3) indirect or shared emissions generated by outsourced activities that benefit INL (occur outside INL's organizational boundaries but are a consequence of INL's activities). This inventory found that INL generated a total of 113,049 MT of CO2-equivalent emissions during FY08. The following conclusions were made from looking at the results of the individual contributors to INL's baseline GHG inventory: (1) Electricity (including the associated transmission and

  14. Bacterial Populations Associated with Smokeless Tobacco Products

    Science.gov (United States)

    Han, Jing; Sanad, Yasser M.; Deck, Joanna; Sutherland, John B.; Li, Zhong; Walters, Matthew J.; Duran, Norma; Holman, Matthew R.

    2016-01-01

    ABSTRACT There are an estimated 8 million users of smokeless tobacco products (STPs) in the United States, and yet limited data on microbial populations within these products exist. To better understand the potential microbiological risks associated with STP use, a study was conducted to provide a baseline microbiological profile of STPs. A total of 90 samples, representing 15 common STPs, were purchased in metropolitan areas in Little Rock, AR, and Washington, DC, in November 2012, March 2013, and July 2013. Bacterial populations were evaluated using culture, pyrosequencing, and denaturing gradient gel electrophoresis (DGGE). Moist-snuff products exhibited higher levels of bacteria (average of 1.05 × 106 CFU/g STP) and diversity of bacterial populations than snus (average of 8.33 × 101 CFU/g STP) and some chewing tobacco products (average of 2.54 × 105 CFU/g STP). The most common species identified by culturing were Bacillus pumilus, B. licheniformis, B. safensis, and B. subtilis, followed by members of the genera Oceanobacillus, Staphylococcus, and Tetragenococcus. Pyrosequencing analyses of the 16S rRNA genes identified the genera Tetragenococcus, Carnobacterium, Lactobacillus, Geobacillus, Bacillus, and Staphylococcus as the predominant taxa. Several species identified are of possible concern due to their potential to cause opportunistic infections and reported abilities to reduce nitrates to nitrites, which may be an important step in the formation of carcinogenic tobacco-specific N′-nitrosamines. This report provides a microbiological baseline to help fill knowledge gaps associated with microbiological risks of STPs and to inform potential regulations regarding manufacture and testing of STPs. IMPORTANCE It is estimated that there 8 million users of smokeless tobacco products (STPs) in the United States; however, there are limited data on microbial populations that exist within these products. The current study was undertaken to better understand the

  15. Baseline frontostriatal-limbic connectivity predicts reward-based memory formation.

    Science.gov (United States)

    Hamann, Janne M; Dayan, Eran; Hummel, Friedhelm C; Cohen, Leonardo G

    2014-12-01

    Reward mediates the acquisition and long-term retention of procedural skills in humans. Yet, learning under rewarded conditions is highly variable across individuals and the mechanisms that determine interindividual variability in rewarded learning are not known. We postulated that baseline functional connectivity in a large-scale frontostriatal-limbic network could predict subsequent interindividual variability in rewarded learning. Resting-state functional MRI was acquired in two groups of subjects (n = 30) who then trained on a visuomotor procedural learning task with or without reward feedback. We then tested whether baseline functional connectivity within the frontostriatal-limbic network predicted memory strength measured immediately, 24 h and 1 month after training in both groups. We found that connectivity in the frontostriatal-limbic network predicted interindividual variability in the rewarded but not in the unrewarded learning group. Prediction was strongest for long-term memory. Similar links between connectivity and reward-based memory were absent in two control networks, a fronto-parieto-temporal language network and the dorsal attention network. The results indicate that baseline functional connectivity within the frontostriatal-limbic network successfully predicts long-term retention of rewarded learning. © 2014 Wiley Periodicals, Inc.

  16. Localizing gravitational wave sources with single-baseline atom interferometers

    Science.gov (United States)

    Graham, Peter W.; Jung, Sunghoon

    2018-02-01

    Localizing sources on the sky is crucial for realizing the full potential of gravitational waves for astronomy, astrophysics, and cosmology. We show that the midfrequency band, roughly 0.03 to 10 Hz, has significant potential for angular localization. The angular location is measured through the changing Doppler shift as the detector orbits the Sun. This band maximizes the effect since these are the highest frequencies in which sources live for several months. Atom interferometer detectors can observe in the midfrequency band, and even with just a single baseline they can exploit this effect for sensitive angular localization. The single-baseline orbits around the Earth and the Sun, causing it to reorient and change position significantly during the lifetime of the source, and making it similar to having multiple baselines/detectors. For example, atomic detectors could predict the location of upcoming black hole or neutron star merger events with sufficient accuracy to allow optical and other electromagnetic telescopes to observe these events simultaneously. Thus, midband atomic detectors are complementary to other gravitational wave detectors and will help complete the observation of a broad range of the gravitational spectrum.

  17. Leveraging probabilistic peak detection to estimate baseline drift in complex chromatographic samples

    NARCIS (Netherlands)

    Lopatka, M.; Barcaru, A.; Sjerps, M.J.; Vivó-Truyols, G.

    2016-01-01

    Accurate analysis of chromatographic data often requires the removal of baseline drift. A frequently employed strategy strives to determine asymmetric weights in order to fit a baseline model by regression. Unfortunately, chromatograms characterized by a very high peak saturation pose a significant

  18. Socioeconomic position and participation in baseline and follow-up visits

    DEFF Research Database (Denmark)

    Bender, Anne M; Jørgensen, Torben; Hansen, Bodil Helbech

    2012-01-01

    Background:The aim of this paper was to identify the extent of socioeconomic inequality in participation at baseline and follow-up visits.Design:The Inter99 study is a randomized intervention with the aim of investigating the effects of an individualized lifestyle consultation on ischaemic heart ...... inequality in participation at baseline and follow-up visits. Effort should be made to increase participation in individualized lifestyle interventions among persons of low socioeconomic position. Otherwise, the consequence may be increased socioeconomic inequality in IHD....

  19. Baseline study of radiology services for the purpose of PACS evaluation

    International Nuclear Information System (INIS)

    Mun, S.K.; Benson, H.; Welsh, C.; Elliott, L.P.; Davros, W.

    1988-01-01

    This paper reports initial results of a radiology department baseline study of workload and data flow patterns for image generation, film library activities, report generation reporting activities at the film alternators and report transcription and validation. The authors analyze the film based operations prior to full implementation of the image management and communication system. The baseline study topics are examined

  20. Baseline LAW Glass Formulation Testing

    International Nuclear Information System (INIS)

    Kruger, Albert A.; Mooers, Cavin; Bazemore, Gina; Pegg, Ian L.; Hight, Kenneth; Lai, Shan Tao; Buechele, Andrew; Rielley, Elizabeth; Gan, Hao; Muller, Isabelle S.; Cecil, Richard

    2013-01-01

    The major objective of the baseline glass formulation work was to develop and select glass formulations that are compliant with contractual and processing requirements for each of the LAW waste streams. Other objectives of the work included preparation and characterization of glasses with respect to the properties of interest, optimization of sulfate loading in the glasses, evaluation of ability to achieve waste loading limits, testing to demonstrate compatibility of glass melts with melter materials of construction, development of glass formulations to support ILAW qualification activities, and identification of glass formulation issues with respect to contract specifications and processing requirements

  1. Baseline atmospheric program Australia 1993

    International Nuclear Information System (INIS)

    Francey, R.J.; Dick, A.L.; Derek, N.

    1996-01-01

    This publication reports activities, program summaries and data from the Cape Grim Baseline Air Pollution Station in Tasmania, during the calendar year 1993. These activities represent Australia's main contribution to the Background Air Pollution Monitoring Network (BAPMoN), part of the World Meteorological Organization's Global Atmosphere Watch (GAW). The report includes 5 research reports covering trace gas sampling, ozone and radon interdependence, analysis of atmospheric dimethylsulfide and carbon-disulfide, sampling of trace gas composition of the troposphere, and sulfur aerosol/CCN relationship in marine air. Summaries of program reports for the calendar year 1993 are also included. Tabs., figs., refs

  2. MERI: an ultra-long-baseline Moon-Earth radio interferometer.

    Science.gov (United States)

    Burns, J. O.

    Radiofrequency aperture synthesis, pioneered by Ryle and his colleagues at Cambridge in the 1960's, has evolved to ever longer baselines and larger arrays in recent years. The limiting resolution at a given frequency for modern ground-based very-long-baseline interferometry is simply determined by the physical diameter of the Earth. A second-generation, totally space-based VLB network was proposed recently by a group at the Naval Research Laboratory. The next logical extension of space-based VLBI would be a station or stations on the Moon. The Moon could serve as an outpost or even the primary correlator station for an extended array of space-based antennas.

  3. The training of verb production in Broca's aphasia : A multiple-baseline across-behaviours study

    NARCIS (Netherlands)

    Bastiaanse, R; Hurkmans, J; Links, P

    2006-01-01

    Background: Verb production is often impaired in Broca's aphasia: Action naming is more affected than object naming and in spontaneous speech the number and/or diversity of lexical verbs is low. Because verbs play a pivotal role in the sentence, these verb problems have a serious impact on the

  4. Impact of an auditory stimulus on baseline cortisol concentrations in clinically normal dogs.

    Science.gov (United States)

    Gin, T E; Puchot, M L; Cook, A K

    2018-03-19

    Baseline cortisol concentrations are routinely used to screen dogs for hypoadrenocorticism (HOC); this diagnosis must then be confirmed with an ACTH stimulation test. A baseline cortisol concentration less than 55 nmol/L (2 μg/dL) is highly sensitive for HOC but lacks specificity, with a false positive rate >20%. Many dogs with nonadrenal disease are therefore subjected to unnecessary additional testing. It was hypothesized that exposure to an unpleasant auditory stimulus before sample collection would improve the specificity of baseline cortisol measurements in dogs with nonadrenal disease by triggering cortisol production. Twenty-eight healthy client-owned dogs were included in the study, with a median age of 4 yr (range 2-9 yr) and a median weight of 20 kg (range 10-27 kg). Dogs were ineligible for inclusion if they had received short- or long-acting glucocorticoids within the previous 30 and 90 d, respectively. Dogs were randomly assigned to group 1 (control; no noise; n = 7), group 2 (brief noise: n = 10), or group 3 (long noise: n = 11). Each dog and owner were directed to a secluded area for approximately 15 min. Group 1 sat in relative quiet, exposed only to the background sounds of a veterinary hospital. Group 2 were exposed to the sound of a wet-dry vacuum in an adjacent hallway during the first 3 min of this period. Group 3 were exposed to random bursts of wet-dry vacuum noise during this period. At the end of the test interval, each dog was escorted to an adjacent examination room for blood collection. Samples were processed within 15 min; serum was frozen at -80°C before measurement of cortisol concentrations. Median serum cortisol concentrations and the proportion of dogs with results dogs with apparently normal adrenal function was therefore rejected. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Wide-Baseline Stereo-Based Obstacle Mapping for Unmanned Surface Vehicles

    Science.gov (United States)

    Mou, Xiaozheng; Wang, Han

    2018-01-01

    This paper proposes a wide-baseline stereo-based static obstacle mapping approach for unmanned surface vehicles (USVs). The proposed approach eliminates the complicated calibration work and the bulky rig in our previous binocular stereo system, and raises the ranging ability from 500 to 1000 m with a even larger baseline obtained from the motion of USVs. Integrating a monocular camera with GPS and compass information in this proposed system, the world locations of the detected static obstacles are reconstructed while the USV is traveling, and an obstacle map is then built. To achieve more accurate and robust performance, multiple pairs of frames are leveraged to synthesize the final reconstruction results in a weighting model. Experimental results based on our own dataset demonstrate the high efficiency of our system. To the best of our knowledge, we are the first to address the task of wide-baseline stereo-based obstacle mapping in a maritime environment. PMID:29617293

  6. 2017 Annual Technology Baseline

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Wesley J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hand, M. M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Eberle, Annika [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Beiter, Philipp C [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kurup, Parthiv [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Turchi, Craig S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Feldman, David J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Margolis, Robert M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Augustine, Chad R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Maness, Michael [Formerly NREL; O' Connor, Patrick [Oak Ridge National Laboratory

    2018-03-26

    Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), the National Renewable Energy Laboratory annually provides an organized and centralized set of such cost and performance data. The ATB uses the best information from the Department of Energy national laboratories' renewable energy analysts as well as information from the Energy Information Administration for fuel-based technologies. The ATB has been reviewed by experts and it includes the following electricity generation technologies: land-based wind, offshore wind, utility-scale solar photovoltaics (PV), commercial-scale solar PV, residential-scale solar PV, concentrating solar power, geothermal power, hydropower, coal, natural gas, nuclear, and conventional biopower. This webinar presentation introduces the 2017 ATB.

  7. Baseline Vascular Cognitive Impairment Predicts the Course of Apathetic Symptoms After Stroke: The CASPER Study.

    Science.gov (United States)

    Douven, Elles; Köhler, Sebastian; Schievink, Syenna H J; van Oostenbrugge, Robert J; Staals, Julie; Verhey, Frans R J; Aalten, Pauline

    2018-03-01

    To examine the influence of vascular cognitive impairment (VCI) on the course of poststroke depression (PSD) and poststroke apathy (PSA). Included were 250 stroke patients who underwent neuropsychological and neuropsychiatric assessment 3 months after stroke (baseline) and at a 6- and 12-month follow-up after baseline. Linear mixed models tested the influence of VCI in at least one cognitive domain (any VCI) or multidomain VCI (VCI in multiple cognitive domains) at baseline and domain-specific VCI at baseline on levels of depression and apathy over time, with random effects for intercept and slope. Almost half of the patients showed any VCI at baseline, and any VCI was associated with increasing apathy levels from baseline to the 12-month follow-up. Patients with multidomain VCI had higher apathy scores at the 6- and 12-month follow-up compared with patients with VCI in a single cognitive domain. Domain-specific analyses showed that impaired executive function and slowed information processing speed went together with increasing apathy levels from baseline to 6- and 12-month follow-up. None of the cognitive variables predicted the course of depressive symptoms. Baseline VCI is associated with increasing apathy levels from baseline to the chronic stroke phase, whereas no association was found between baseline VCI and the course of depressive symptoms. Health professionals should be aware that apathy might be absent early after stroke but may evolve over time in patients with VCI. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Twenty-month follow-up of occlusal caries lesions deemed questionable at baseline

    DEFF Research Database (Denmark)

    Makhija, Sonia K; Gilbert, Gregg H; Funkhouser, Ellen

    2014-01-01

    -three clinicians from The National Dental Practice-Based Research Network participated in this study, recording lesion characteristics at baseline and lesion status at 20 months. RESULTS: At baseline, 1,341 QOC lesions were examined; the treatment that was planned for 1,033 of those at baseline was monitoring...... (oral hygiene instruction, applying or prescribing fluoride or varnish, or both), and the remaining 308 received a sealant (n = 192) or invasive therapy (n = 116). At the 20-month visit, clinicians continued to monitor 927 (90 percent) of the 1,033 monitored lesions. Clinicians decided to seal 61 (6...

  9. 40 CFR 80.245 - How does a small refiner apply for a sulfur baseline?

    Science.gov (United States)

    2010-07-01

    ... sulfur baseline? 80.245 Section 80.245 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Provisions § 80.245 How does a small refiner apply for a sulfur baseline? (a) Any refiner seeking small refiner status must apply for a refinery sulfur baseline by the deadline under § 80.235 for each of the...

  10. TECHNICAL EFFICIENCY AND IMPACT EVALUATION DIFFERENTIALS BETWEEN THE ADOPTERS AND NON-ADOPTERS OF NERICA IN THE SIX BASELINE STATES IN NIGERIA

    Directory of Open Access Journals (Sweden)

    Abiodun Elijah OBAYELU

    2017-04-01

    Full Text Available The study examined the adoption rate of New Rice for Africa (NERICA, technical efficiency differentials of production of these varieties between adopters and non-adopters and the determinants. It further analysed the impact of adoption of NERICA on area cultivated, output, yield, expenditure and total income of rice farmers in the NERICA baseline states in Nigeria. To achieve the objectives, it employed the descriptive statistics, stochastic production frontier and counterfactual outcomes framework of modern evaluation technique (the Local Average Treatment Effect to analyse 621 rice farmers across the six NERICA baseline states in Nigeria in 2012. The findings show that NERICA adopters were more technically efficient than the non-adopters. In addition, adoption of NERICA was found to significantly increase the areas of land cultivated, output, yield, household expenditure, per capita household expenditure and total income among NERICA adopters by 1.2ha (p < 0.01, 1998.2kg (p< 0.01, 191.2kg/ha (p < 0.1, N13,222.63≈$66.4 (p < 0.05, N2,015.6≈$10.1 (p < 0.05 and N145,098.7 ≈$728.0 (p < 0.01 respectively despite their high level of inefficiency (39 percent by the adopters. The positive impact of NERICA adoption on rice yields, poverty status measured by the per capita household expenditure and total farm income of farmers is a clear indication that NERICA has the potential to increase rice productivity, reduce poverty and food insecurity. NERICA adoption rate will rise if more farmers are aware of the varieties in the study. Farmers who had adopted, and government at all levels should therefore intensify their efforts to encourage others rice farmers possibly through the extension agents on the need to grow NERICA varieties so as to increase rice production level, reduce rice importation and ensure a sustainable rice production.

  11. The steroids for corneal ulcers trial: study design and baseline characteristics.

    Science.gov (United States)

    Srinivasan, Muthiah; Mascarenhas, Jeena; Rajaraman, Revathi; Ravindran, Meenakshi; Lalitha, Prajna; Glidden, David V; Ray, Kathryn J; Hong, Kevin C; Oldenburg, Catherine E; Lee, Salena M; Zegans, Michael E; McLeod, Stephen D; Lietman, Thomas M; Acharya, Nisha R

    2012-02-01

    To provide comprehensive trial methods and baseline data for the Steroids for Corneal Ulcers Trial and to present epidemiological characteristics such as risk factors, causative organisms, and ulcer severity. Baseline data from a 1:1 randomized, placebo-controlled, double-masked clinical trial comparing prednisolone phosphate, 1%, with placebo as adjunctive therapy for the treatment of bacterial corneal ulcers. Eligible patients had a culture-positive bacterial corneal ulcer and had been taking moxifloxacin for 48 hours. The primary outcome for the trial is best spectacle-corrected visual acuity at 3 months from enrollment. This report provides comprehensive baseline data, including best spectacle-corrected visual acuity, infiltrate size, microbiological results, and patient demographics, for patients enrolled in the trial. Of 500 patients enrolled, 97% were in India. Two hundred twenty patients (44%) were agricultural workers. Median baseline visual acuity was 0.84 logMAR (Snellen, 20/125) (interquartile range, 0.36-1.7; Snellen, 20/50 to counting fingers). Baseline visual acuity was not significantly different between the United States and India. Ulcers in India had larger infiltrate/scar sizes (P = .04) and deeper infiltrates (P = .04) and were more likely to be localized centrally (P = .002) than ulcers enrolled in the United States. Gram-positive bacteria were the most common organisms isolated from the ulcers (n = 366, 72%). The Steroids for Corneal Ulcers Trial will compare the use of a topical corticosteroid with placebo as adjunctive therapy for bacterial corneal ulcers. Patients enrolled in this trial had diverse ulcer severity and on average significantly reduced visual acuity at presentation. clinicaltrials.gov Identifier: NCT00324168.

  12. 77 FR 21760 - Atmos Energy Colorado/Kansas Division; Notice of Baseline Filing

    Science.gov (United States)

    2012-04-11

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR12-19-000] Atmos Energy Colorado/Kansas Division; Notice of Baseline Filing Take notice that on March 30, 2012, Atmos Energy Colorado/Kansas Division (Atmos) submitted a baseline filing of their Statement of Operating Conditions for...

  13. Forecasting Sensorimotor Adaptability from Baseline Inter-Trial Correlations

    Science.gov (United States)

    Beaton, K. H.; Bloomberg, J. J.

    2016-01-01

    One of the greatest challenges for sensorimotor adaptation to the spaceflight environment is the large variability in symptoms, and corresponding functional impairments, from one crewmember to the next. This renders preflight training and countermeasure development difficult, as a "one-size-fits-all" approach is inappropriate. Therefore, it would be highly advantageous to know ahead of time which crewmembers might have more difficulty adjusting to the novel g-levels inherent to spaceflight. This information could guide individually customized countermeasures, which would enable more efficient use of crew time and provide better outcomes. The principal aim of this work is to look for baseline performance metrics that relate to locomotor adaptability. We propose a novel hypothesis that considers baseline inter-trial correlations, the trial-to-trial fluctuations ("noise") in motor performance, as a predictor of individual adaptive capabilities.

  14. Baseline Neurocognitive Test Results In Non-concussed Athletes: Does Sleep Matter?

    OpenAIRE

    McClure, D. Jake; Zuckerman, Scott L.; Kutscher, Scott J.; Gregory, Andrew; Solomon, Gary S.

    2013-01-01

    Objectives: When managing sport-related concussions (SRC), sports medicine physicians utilize serial neurocognitive assessments and self-reported symptom inventories when evaluating athlete recovery and safety for returning to play (RTP). Since post-concussive RTP goals include symptom resolution and return to neurocognitive baseline, clinical decisions rest on an understanding of modifiers of baseline performance. Several studies have reported the influence of age, gender and sport on baseli...

  15. Quality baseline of the castilla blackberry (Rubus glaucus in its food chain

    Directory of Open Access Journals (Sweden)

    Fernanda Iza

    2016-09-01

    Full Text Available A proposal for improvement in the performance of the food chain of castilla blackberry (Rubus glaucus in order to potentiate their productivity can only start from a baseline or situational diagnosis of the quality of the fruit and hence identify the main points of improvement. The food chain of the fruit identifies three stages, harvest, post-harvest (storage and transport and marketing or sale. The diagnosis in each stage began with reverse mode. It was identified the most representative producer and the supplying for traders to the point of sale. The quality evaluation of the fruit was performed through chemical and physical characterization in the four stages. Weight loss or losses were evident in all stages, light no significant changes of color from bright red bluish hue in the collection stage until opaque bluish red or off, at the stage of sale due to the short cycle time and the characteristics non-climacteric fruit. However, at all stages of collection, storage, transportation and sale, they presented significant changes in the indices of maturity which meant an increase of sugars, decreased of pH, and increase acidity. The results indicate that the fruit changed its physicochemical characteristics during the stages of the food chain affecting its productivity.

  16. Astrometry of 25 Southern Hemisphere Radio Sources From A VLBI Short-Baseline Survey

    National Research Council Canada - National Science Library

    Fey, Alan

    2004-01-01

    .... These positions are derived from Mark III Very Long Baseline Interferometry observations made between 2003 September and 2004 May on the intra-Australia baseline connecting Hobart, Tasmania and Parkes, New South Wales...

  17. Baseline and cognition activated brain SPECT imaging in depression

    International Nuclear Information System (INIS)

    Zhao Jinhua; Lin Xiangtong; Jiang Kaida; Liu Yongchang; Xu Lianqin

    1998-01-01

    Purpose: To evaluate the regional cerebral blood flow (rCBF) abnormalities through the semiquantitative analysis of the baseline and cognition activated rCBF imaging in unmedicated depressed patients. Methods: 27 depressed patients unmedicated by anti-depressants were enrolled. The diagnosis (depression of moderate degree with somatization) was confirmed by the ICD-10 criteria. 15 age matched normal controls were studied under identical conditions. Baseline and cognition activated 99m Tc-ECD SPECT were performed on 21 of the 27 patients with depression and 13 of the 15 normal controls. Baseline 99m Tc-ECD SPECT alone were performed on the rest 6 patients with depression and 2 normal controls. The cognitive activation is achieved by Wisconsin Card Sorting Test (WCST). 1110 MBq of 99m Tc-ECD was administered by intravenous bolus injection 5 minutes after the onset of the WCST. Semi-quantitative analysis was conducted with the 7th, 8th, 9th, 10th, 11th slices of the transaxial imaging. rCBF ratios of every ROI were calculated using the average tissue activity in the region divided by the maximum activity in the cerebellum. Results: 1) The baseline rCBF of left frontal (0.720) and left temporal lobe (0.720) were decreased significantly in depressed patients comparing with those of the control subjects. 2) The activated rCBF of left frontal lobe (0.719) and left temporal lobe (0.690), left parietal lobe (0.701) were decreased evidently than those of the controls. Conclusions: 1) Hypoperfusions of left frontal and left temporal cortexes were identified in patients with depression. 2) The hypoperfusion of left frontal and left temporal cortexes may be the cause of cognition disorder and depressed mood in patients with depression. 3) Cognition activated brain perfusion imaging is helpful for making a more accurate diagnosis of depression

  18. How to deal with cost differences at baseline

    NARCIS (Netherlands)

    Van Asselt, Antoinette D.I.; Van Mastrigt, Ghislaine A.P.G.; Dirksen, Carmen D.; Arntz, Arnoud; Severens, Johan L.; Kessels, Alfons G.H.

    BACKGROUND: To our knowledge, adjustment for baseline imbalances in costs has never been performed in trial-based cost-effectiveness analyses. METHODS: We used data from a clinical trial performed in the Netherlands comparing two outpatient psychotherapies: schema-focused therapy (SFT) versus

  19. High baseline activity in inferior temporal cortex improves neural and behavioral discriminability during visual categorization

    Science.gov (United States)

    Emadi, Nazli; Rajimehr, Reza; Esteky, Hossein

    2014-01-01

    Spontaneous firing is a ubiquitous property of neural activity in the brain. Recent literature suggests that this baseline activity plays a key role in perception. However, it is not known how the baseline activity contributes to neural coding and behavior. Here, by recording from the single neurons in the inferior temporal cortex of monkeys performing a visual categorization task, we thoroughly explored the relationship between baseline activity, the evoked response, and behavior. Specifically we found that a low-frequency (baseline activity. This enhancement of the baseline activity was then followed by an increase in the neural selectivity and the response reliability and eventually a higher behavioral performance. PMID:25404900

  20. Choice of baseline climate data impacts projected species' responses to climate change.

    Science.gov (United States)

    Baker, David J; Hartley, Andrew J; Butchart, Stuart H M; Willis, Stephen G

    2016-07-01

    Climate data created from historic climate observations are integral to most assessments of potential climate change impacts, and frequently comprise the baseline period used to infer species-climate relationships. They are often also central to downscaling coarse resolution climate simulations from General Circulation Models (GCMs) to project future climate scenarios at ecologically relevant spatial scales. Uncertainty in these baseline data can be large, particularly where weather observations are sparse and climate dynamics are complex (e.g. over mountainous or coastal regions). Yet, importantly, this uncertainty is almost universally overlooked when assessing potential responses of species to climate change. Here, we assessed the importance of historic baseline climate uncertainty for projections of species' responses to future climate change. We built species distribution models (SDMs) for 895 African bird species of conservation concern, using six different climate baselines. We projected these models to two future periods (2040-2069, 2070-2099), using downscaled climate projections, and calculated species turnover and changes in species-specific climate suitability. We found that the choice of baseline climate data constituted an important source of uncertainty in projections of both species turnover and species-specific climate suitability, often comparable with, or more important than, uncertainty arising from the choice of GCM. Importantly, the relative contribution of these factors to projection uncertainty varied spatially. Moreover, when projecting SDMs to sites of biodiversity importance (Important Bird and Biodiversity Areas), these uncertainties altered site-level impacts, which could affect conservation prioritization. Our results highlight that projections of species' responses to climate change are sensitive to uncertainty in the baseline climatology. We recommend that this should be considered routinely in such analyses. © 2016 John Wiley

  1. The impact of GPS receiver modifications and ionospheric activity on Swarm baseline determination

    Science.gov (United States)

    Mao, X.; Visser, P. N. A. M.; van den IJssel, J.

    2018-05-01

    The European Space Agency (ESA) Swarm mission is a satellite constellation launched on 22 November 2013 aiming at observing the Earth geomagnetic field and its temporal variations. The three identical satellites are equipped with high-precision dual-frequency Global Positioning System (GPS) receivers, which make the constellation an ideal test bed for baseline determination. From October 2014 to August 2016, a number of GPS receiver modifications and a new GPS Receiver Independent Exchange Format (RINEX) converter were implemented. Moreover, the on-board GPS receiver performance has been influenced by the ionospheric scintillations. The impact of these factors is assessed for baseline determination of the pendulum formation flying Swarm-A and -C satellites. In total 30 months of data - from 15 July 2014 to the end of 2016 - is analyzed. The assessment includes analysis of observation residuals, success rate of GPS carrier phase ambiguity fixing, a consistency check between the so-called kinematic and reduced-dynamic baseline solution, and validations of orbits by comparing with Satellite Laser Ranging (SLR) observations. External baseline solutions from The German Space Operations Center (GSOC) and Astronomisches Institut - Universität Bern (AIUB) are also included in the comparison. Results indicate that the GPS receiver modifications and RINEX converter changes are effective to improve the baseline determination. This research eventually shows a consistency level of 9.3/4.9/3.0 mm between kinematic and reduced-dynamic baselines in the radial/along-track/cross-track directions. On average 98.3% of the epochs have kinematic solutions. Consistency between TU Delft and external reduced-dynamic baseline solutions is at a level of 1 mm level in all directions.

  2. Addendum to the 2015 Eastern Interconnect Baselining and Analysis Report

    Energy Technology Data Exchange (ETDEWEB)

    Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Follum, James D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-30

    This report serves as an addendum to the report 2015 Eastern Interconnect Baselining and Analysis Report (Amidan, Follum, and Freeman, 2015). This addendum report investigates the following: the impact of shorter record lengths and of adding a daily regularization term to the date/time models for angle pair measurements, additional development of a method to monitor the trend in phase angle pairs, the effect of changing the length of time to determine a baseline, when calculating atypical events, and a comparison between quantitatively discovered atypical events and actual events.

  3. Synoptic events force biological productivity in Patagonian fjord ecosystems

    Science.gov (United States)

    Daneri, Giovanni

    2016-04-01

    The annual cycle of primary productivity of the Patagonian fjords has, to date, been described as a two phase system consisting of a short non productive winter phase (during June and July) and a productive phase extending from late winter (August) to autumn (May). Low levels of primary production, phytoplankton biomass and high concentrations of surface nutrients have been described as characterizing winter conditions while pulsed productivity events typifies the productivity pattern during the extended productive season. Pulsed productivity events characterize coastal waters where inorganic nutrients in surface layers are replenished following periods of intensive utilization by autotrophs. Freshwater input in Patagonian fjords in southern Chile (41-55°S) results in one of the largest estuarine regions worldwide. Here strong haline water column stratification prevents nutrient mixing to the surface layers thus potentially shutting off algal production. Our working hypothesis considered that in order to reconcile the observed pulsed productivity pattern, periodic breaking (associated to surface nutrient replenishment) and re-establishment of estuarine conditions (associated to water column stratification) would be required. Up to now however our understanding of the physical processes that control water column conditions in the Patagonian fjord area has been extremely limited. Here we present evidence linking the passage of synoptic low pressure fronts to pulsed productivity events in the Patagonian fjord area. These front controls and influence local processes of interaction between the fjord and the atmosphere generating a rapid water column response. In the specific case of the Puyuhuapi fjord we have been able to show that such synoptic fronts induce surface flow reversal and water column mixing. Phytoplankton blooming occurs after the passage of the synoptic front once calmer conditions prevail and estuarine conditions are re established. The occurrence of

  4. Elevated prostaglandin E metabolites and abnormal plasma fatty acids at baseline in pediatric cystic fibrosis patients: a pilot study.

    Science.gov (United States)

    O'Connor, Michael Glenn; Thomsen, Kelly; Brown, Rebekah F; Laposata, Michael; Seegmiller, Adam

    2016-10-01

    Airway inflammation is a significant contributor to the morbidity of cystic fibrosis (CF) disease. One feature of this inflammation is the production of oxygenated metabolites, such as prostaglandins. Individuals with CF are known to have abnormal metabolism of fatty acids, typically resulting in reduced levels of linoleic acid (LA) and docosahexaenoic acid (DHA). This is a randomized, double-blind, cross-over clinical trial of DHA supplementation with endpoints of plasma fatty acid levels and prostaglandin E metabolite (PGE-M) levels. Patients with CF age 6-18 years with pancreatic insufficiency were recruited. Each participant completed 3 four-week study periods: DHA at two different doses (high dose and low dose) and placebo with a minimum 4 week wash-out between each period. Blood, urine, and exhaled breath condensate (EBC) were collected at baseline and after each study period for measurement of plasma fatty acids as well as prostaglandin E metabolites. Seventeen participants were enrolled, and 12 participants completed all 3 study periods. Overall, DHA supplementation was well tolerated without significant adverse events. There was a significant increase in plasma DHA levels with supplementation, but no significant change in arachidonic acid (AA) or LA levels. However, at baseline, AA levels were lower and LA levels were higher than previously reported for individuals with CF. Urine PGE-M levels were elevated in the majority of participants at baseline, and while levels decreased with DHA supplementation, they also decreased with placebo. Urine PGE-M levels are elevated at baseline in this cohort of pediatric CF patients, but there was no significant change in these levels with DHA supplementation compared to placebo. In addition, baseline plasma fatty acid levels for this cohort showed some difference to prior reports, including higher levels of LA and lower levels of AA, which may reflect changes in clinical care, and consequently warrants further

  5. A Mean-Shift-Based Feature Descriptor for Wide Baseline Stereo Matching

    Directory of Open Access Journals (Sweden)

    Yiwen Dou

    2015-01-01

    Full Text Available We propose a novel Mean-Shift-based building approach in wide baseline. Initially, scale-invariance feature transform (SIFT approach is used to extract relatively stable feature points. As to each matching SIFT feature point, it needs a reasonable neighborhood range so as to choose feature points set. Subsequently, in view of selecting repeatable and high robust feature points, Mean-Shift controls corresponding feature scale. At last, our approach is employed to depth image acquirement in wide baseline and Graph Cut algorithm optimizes disparity information. Compared with the existing methods such as SIFT, speeded up robust feature (SURF, and normalized cross-correlation (NCC, the presented approach has the advantages of higher robustness and accuracy rate. Experimental results on low resolution image and weak feature description in wide baseline confirm the validity of our approach.

  6. Profile of NASA software engineering: Lessons learned from building the baseline

    Science.gov (United States)

    Hall, Dana; Mcgarry, Frank

    1993-01-01

    It is critically important in any improvement activity to first understand the organization's current status, strengths, and weaknesses and, only after that understanding is achieved, examine and implement promising improvements. This fundamental rule is certainly true for an organization seeking to further its software viability and effectiveness. This paper addresses the role of the organizational process baseline in a software improvement effort and the lessons we learned assembling such an understanding for NASA overall and for the NASA Goddard Space Flight Center in particular. We discuss important, core data that must be captured and contrast that with our experience in actually finding such information. Our baselining efforts have evolved into a set of data gathering, analysis, and crosschecking techniques and information presentation formats that may prove useful to others seeking to establish similar baselines for their organization.

  7. Wide baseline stereo matching based on double topological relationship consistency

    Science.gov (United States)

    Zou, Xiaohong; Liu, Bin; Song, Xiaoxue; Liu, Yang

    2009-07-01

    Stereo matching is one of the most important branches in computer vision. In this paper, an algorithm is proposed for wide-baseline stereo vision matching. Here, a novel scheme is presented called double topological relationship consistency (DCTR). The combination of double topological configuration includes the consistency of first topological relationship (CFTR) and the consistency of second topological relationship (CSTR). It not only sets up a more advanced model on matching, but discards mismatches by iteratively computing the fitness of the feature matches and overcomes many problems of traditional methods depending on the powerful invariance to changes in the scale, rotation or illumination across large view changes and even occlusions. Experimental examples are shown where the two cameras have been located in very different orientations. Also, epipolar geometry can be recovered using RANSAC by far the most widely method adopted possibly. By the method, we can obtain correspondences with high precision on wide baseline matching problems. Finally, the effectiveness and reliability of this method are demonstrated in wide-baseline experiments on the image pairs.

  8. Very long baseline interferometry applied to polar motion, relativity, and geodesy. Ph.D. thesis

    International Nuclear Information System (INIS)

    Ma, C.

    1978-01-01

    The causes and effects of diurnal polar motion are described. An algorithm was developed for modeling the effects on very long baseline interferometry observables. A selection was made between two three-station networks for monitoring polar motion. The effects of scheduling and the number of sources observed on estimated baseline errors are discussed. New hardware and software techniques in very long baseline interferometry are described

  9. Normal milk microbiome is reestablished following experimental infection with Escherichia coli independent of intramammary antibiotic treatment with a third-generation cephalosporin in bovines.

    Science.gov (United States)

    Ganda, Erika K; Gaeta, Natalia; Sipka, Anja; Pomeroy, Brianna; Oikonomou, Georgios; Schukken, Ynte H; Bicalho, Rodrigo C

    2017-07-12

    The use of antimicrobials in food animals and the emergence of antimicrobial resistance are global concerns. Ceftiofur is the only third-generation cephalosporin labeled for veterinary use in the USA, and it is the drug of choice in the majority of dairy farms for the treatment of mastitis. Here, we use next-generation sequencing to describe longitudinal changes that occur in the milk microbiome before, during, and after infection and treatment with ceftiofur. Twelve animals were intramammary challenged with Escherichia coli in one quarter and randomly allocated to receive intramammary treatment with ceftiofur (5d) or untreated controls. Serial samples were collected from -72 to 216 h relative to challenge from the challenged quarter, an ipsilateral quarter assigned to the same treatment group, and from a third quarter that did not undergo intervention. Infection with E. coli dramatically impacted microbial diversity. Ceftiofur significantly decreased LogCFUs but had no significant effect on the milk microbiome, rate of pathogen clearance, or somatic cell count. At the end of the study, the microbial profile of infected quarters was indistinguishable from pre-challenge samples in both treated and untreated animals. Intramammary infusion with ceftiofur did not alter the healthy milk (i.e., milk devoid of clots or serous appearance and collected from a mammary gland that shows no clinical signs of mastitis) microbiome. Our results indicate that the mammary gland harbors a resilient microbiome, capable of reestablishing itself after experimental infection with E. coli independent of antimicrobial treatment.

  10. Earth matter effects at very long baselines and the neutrino mass hierarchy

    International Nuclear Information System (INIS)

    Gandhi, Raj; Ghoshal, Pomita; Goswami, Srubabati; Mehta, Poonam; Sankar, S. Uma

    2006-01-01

    We study matter effects which arise in the muon neutrino oscillation and survival probabilities relevant to atmospheric neutrino and very long baseline (>4000 Km) beam experiments. The interrelations between the three probabilities P μe , P μτ , and P μμ are examined. It is shown that large and observable sensitivity to the neutrino mass hierarchy can be present in P μμ and P μτ . We emphasize that at baselines >7000 Km, matter effects in P μτ are important under certain conditions and can be large. The muon survival rates in experiments with very long baselines thus depend on matter effects in both P μτ and P μe . We also indicate where these effects provide sensitivity to θ 13 and identify ranges of energies and baselines where this sensitivity is maximum. The effect of parameter degeneracies in the three probabilities at these baselines and energies is studied in detail and large parts of the parameter space are identified which are free from these degeneracies. In the second part of the paper, we focus on using the matter effects studied in the first part as a means of determining the mass hierarchy via atmospheric neutrinos. Realistic event rate calculations are performed for a charge discriminating 100 kT iron calorimeter which demonstrate the possibility of realizing this very important goal in neutrino physics. It is shown that for atmospheric neutrinos, a careful selection of energy and baseline ranges is necessary in order to obtain a statistically significant signal, and that the effects are largest in bins where matter effects in both P μe and P μτ combine constructively. Under these conditions, up to a 4σ signal for matter effects is possible (for Δ 31 >0) within a time scale appreciably shorter than the one anticipated for neutrino factories

  11. Improving the accuracy of energy baseline models for commercial buildings with occupancy data

    International Nuclear Information System (INIS)

    Liang, Xin; Hong, Tianzhen; Shen, Geoffrey Qiping

    2016-01-01

    Highlights: • We evaluated several baseline models predicting energy use in buildings. • Including occupancy data improved accuracy of baseline model prediction. • Occupancy is highly correlated with energy use in buildings. • This simple approach can be used in decision makings of energy retrofit projects. - Abstract: More than 80% of energy is consumed during operation phase of a building’s life cycle, so energy efficiency retrofit for existing buildings is considered a promising way to reduce energy use in buildings. The investment strategies of retrofit depend on the ability to quantify energy savings by “measurement and verification” (M&V), which compares actual energy consumption to how much energy would have been used without retrofit (called the “baseline” of energy use). Although numerous models exist for predicting baseline of energy use, a critical limitation is that occupancy has not been included as a variable. However, occupancy rate is essential for energy consumption and was emphasized by previous studies. This study develops a new baseline model which is built upon the Lawrence Berkeley National Laboratory (LBNL) model but includes the use of building occupancy data. The study also proposes metrics to quantify the accuracy of prediction and the impacts of variables. However, the results show that including occupancy data does not significantly improve the accuracy of the baseline model, especially for HVAC load. The reasons are discussed further. In addition, sensitivity analysis is conducted to show the influence of parameters in baseline models. The results from this study can help us understand the influence of occupancy on energy use, improve energy baseline prediction by including the occupancy factor, reduce risks of M&V and facilitate investment strategies of energy efficiency retrofit.

  12. Effects of baseline conditions on the simulated hydrologic response to projected climate change

    Science.gov (United States)

    Koczot, Kathryn M.; Markstrom, Steven L.; Hay, Lauren E.

    2011-01-01

    Changes in temperature and precipitation projected from five general circulation models, using one late-twentieth-century and three twenty-first-century emission scenarios, were downscaled to three different baseline conditions. Baseline conditions are periods of measured temperature and precipitation data selected to represent twentieth-century climate. The hydrologic effects of the climate projections are evaluated using the Precipitation-Runoff Modeling System (PRMS), which is a watershed hydrology simulation model. The Almanor Catchment in the North Fork of the Feather River basin, California, is used as a case study. Differences and similarities between PRMS simulations of hydrologic components (i.e., snowpack formation and melt, evapotranspiration, and streamflow) are examined, and results indicate that the selection of a specific time period used for baseline conditions has a substantial effect on some, but not all, hydrologic variables. This effect seems to be amplified in hydrologic variables, which accumulate over time, such as soil-moisture content. Results also indicate that uncertainty related to the selection of baseline conditions should be evaluated using a range of different baseline conditions. This is particularly important for studies in basins with highly variable climate, such as the Almanor Catchment.

  13. Infrared thermometry and the crop water stress index. I. History, theory, and baselines

    International Nuclear Information System (INIS)

    Gardner, B.R.; Nielsen, D.C.; Shock, C.C.

    1992-01-01

    Development of portable infrared thermometers and the definition of the Crop Water Stress Index (CWSI) have led to widespread interest in infrared thermometry to monitor water stress and schedule irrigations. But the CWSI concept is still new and poorly understood by many. The purpose of this paper is to review the definition of CWSI, and the determination and interpretation of the non-water-stressed baselines used to compute CWSI. The non-water-stressed baseline equation normalizes the canopy minus air temperature differential for variations in vapor pressure deficit. Non-water-stressed baselines can be determined empirically from measurements of canopy and air temperatures and vapor pressure deficit, made diurnally on a single day, or at a single time of day over many days, on well-watered plants. The value of the maximum canopy minus air temperature differential under maximum water stress should also be determined empirically. Causes for CWSI values falling outside of the defined 0 to 10 unit range are reviewed. Non-water-stressed baselines may shift with plant growth stage. Effective use of CWSI is dependent on understanding the definition of CWSI, and the proper determination and use of non-water-stressed baselines. (author)

  14. Leveraging probabilistic peak detection to estimate baseline drift in complex chromatographic samples.

    Science.gov (United States)

    Lopatka, Martin; Barcaru, Andrei; Sjerps, Marjan J; Vivó-Truyols, Gabriel

    2016-01-29

    Accurate analysis of chromatographic data often requires the removal of baseline drift. A frequently employed strategy strives to determine asymmetric weights in order to fit a baseline model by regression. Unfortunately, chromatograms characterized by a very high peak saturation pose a significant challenge to such algorithms. In addition, a low signal-to-noise ratio (i.e. s/npeak detection algorithm. A posterior probability of being affected by a peak is computed for each point in the chromatogram, leading to a set of weights that allow non-iterative calculation of a baseline estimate. For extremely saturated chromatograms, the peak weighted (PW) method demonstrates notable improvement compared to the other methods examined. However, in chromatograms characterized by low-noise and well-resolved peaks, the asymmetric least squares (ALS) and the more sophisticated Mixture Model (MM) approaches achieve superior results in significantly less time. We evaluate the performance of these three baseline correction methods over a range of chromatographic conditions to demonstrate the cases in which each method is most appropriate. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Rural Poultry Production in Ondo South Senatorial District Area of ...

    African Journals Online (AJOL)

    Rural Poultry Production in Ondo South Senatorial District Area of Ondo State, Nigeria. ... African Journal of Livestock Extension ... The need to obtain baseline information on rural poultry with respect to their population and the production potentials of the indigenous chicken under the village conditions in Ondo Area formed ...

  16. Problems of Frafra potato production in Ghana | Tetteh | Ghana ...

    African Journals Online (AJOL)

    A survey of the production of Frafra potato (Solenostemum rotundifolius Poir) in Ghana was conducted to collect baseline data on the crop and to identify constraints to production. In all, 100 farmers who were randomly selected from 16 villages and towns in five districts in the Upper East Region and Upper West Region ...

  17. Baseline ecological risk assessment Salmon Site, Lamar County, Mississippi

    International Nuclear Information System (INIS)

    1995-04-01

    The Salmon Site (SS), formerly the Tatum Dome Test Site, located in Mississippi was the site of two nuclear and two gas explosion tests conducted between 1964 and 1970. A consequence of these testing activities is that radionuclides were released into the salt dome, where they are presently contained. During reentry drilling and other site activities, incidental liquid and solid wastes that contained radioactivity were generated, resulting in some soil, ground water and equipment contamination. As part of the remedial investigation effort, a Baseline Ecological Risk Assessment was conducted at the SS. The purpose is to gauge ecological and other environmental impacts attributable to past activities at the former test facility. The results of this facility-specific baseline risk assessment are presented in this document

  18. Baseline ecological risk assessment Salmon Site, Lamar County, Mississippi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    The Salmon Site (SS), formerly the Tatum Dome Test Site, located in Mississippi was the site of two nuclear and two gas explosion tests conducted between 1964 and 1970. A consequence of these testing activities is that radionuclides were released into the salt dome, where they are presently contained. During reentry drilling and other site activities, incidental liquid and solid wastes that contained radioactivity were generated, resulting in some soil, ground water and equipment contamination. As part of the remedial investigation effort, a Baseline Ecological Risk Assessment was conducted at the SS. The purpose is to gauge ecological and other environmental impacts attributable to past activities at the former test facility. The results of this facility-specific baseline risk assessment are presented in this document.

  19. Energy conservation on Nova Scotia farms: Baseline energy data

    International Nuclear Information System (INIS)

    Bailey, J.A.; Gordon, R.; Burton, D.; Yiridoe, E.K.

    2008-01-01

    Direct energy use is a small but essential component of the farm greenhouse gas (GHG) budget. Improvements in energy efficiency and renewable energy can help reduce farm operating costs, improve air quality and reduce GHG emission levels. Energy conservation is especially important in Nova Scotia (NS), Canada, where fossil fuels, particularly coal, remain the primary source of electrical generation. Responses from mail surveys were used to establish baseline data on a cross-section of NS farms with respect to direct energy costs and usage to demonstrate differences in farm type and size. A 32% (N=224) response rate was achieved. Based on this survey, the average energy bill for a NS farm in 2004 was $11,228, with most (61.7%) of their energy cost attributable to the purchase of petroleum products. Almost all farmers (96.4%) indicated that their energy cost was a primary concern. Farmers identified the operation of vehicles and mobile equipment, as well as lighting and heating as having the greatest energy requirements in their operations. Energy usage varied with farm type and size. NS farms consumed 1.2 petajoules of energy equivalent to 127 kilotonnes of CO 2 with 52.7% of emissions from electricity use in 2004

  20. 40 CFR 80.910 - How does a refiner or importer apply for a toxics baseline?

    Science.gov (United States)

    2010-07-01

    ... for a toxics baseline? 80.910 Section 80.910 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Toxics Baseline Determination § 80.910 How does a refiner or importer apply for a toxics baseline? (a)(1) A refiner or importer...

  1. Idaho National Laboratory’s Greenhouse Gas FY08 Baseline

    Energy Technology Data Exchange (ETDEWEB)

    Jennifer D. Morton

    2010-09-01

    A greenhouse gas (GHG) inventory is a systematic attempt to account for the production and release of certain gasses generated by an institution from various emission sources. The gasses of interest are those which have become identified by climate science as related to anthropogenic global climate change. This document presents an inventory of GHGs generated during fiscal year (FY) 2008 by Idaho National Laboratory (INL), a Department of Energy (DOE)-sponsored entity, located in southeastern Idaho. Concern about the environmental impact of GHGs has grown in recent years. This, together with a desire to decrease harmful environmental impacts, would be enough to encourage the calculation of a baseline estimate of total GHGs generated at the INL. Additionally, the INL has a desire to see how its emissions compare with similar institutions, including other DOE-sponsored national laboratories. Executive Order 13514 requires that federally-sponsored agencies and institutions document reductions in GHG emissions in the future, and such documentation will require knowledge of a baseline against which reductions can be measured. INL’s FY08 GHG inventory was calculated according to methodologies identified in Federal recommendations and an as-yet-unpublished Technical and Support Document (TSD) using operational control boundary. It measures emissions generated in three Scopes: (1) INL emissions produced directly by stationary or mobile combustion and by fugitive emissions, (2) the share of emissions generated by entities from which INL purchased electrical power, and (3) indirect or shared emissions generated by outsourced activities that benefit INL (occur outside INL’s organizational boundaries but are a consequence of INL’s activities). This inventory found that INL generated a total of 114,256 MT of CO2-equivalent emissions during fiscal year 2008 (FY08). The following conclusions were made from looking at the results of the individual contributors to INL

  2. NETWORK DESIGN IN CLOSE-RANGE PHOTOGRAMMETRY WITH SHORT BASELINE IMAGES

    Directory of Open Access Journals (Sweden)

    L. Barazzetti

    2017-08-01

    Full Text Available The avaibility of automated software for image-based 3D modelling has changed the way people acquire images for photogrammetric applications. Short baseline images are required to match image points with SIFT-like algorithms, obtaining more images than those necessary for “old fashioned” photogrammetric projects based on manual measurements. This paper describes some considerations on network design for short baseline image sequences, especially on precision and reliability of bundle adjustment. Simulated results reveal that the large number of 3D points used for image orientation has very limited impact on network precision.

  3. A fully automated algorithm of baseline correction based on wavelet feature points and segment interpolation

    Science.gov (United States)

    Qian, Fang; Wu, Yihui; Hao, Peng

    2017-11-01

    Baseline correction is a very important part of pre-processing. Baseline in the spectrum signal can induce uneven amplitude shifts across different wavenumbers and lead to bad results. Therefore, these amplitude shifts should be compensated before further analysis. Many algorithms are used to remove baseline, however fully automated baseline correction is convenient in practical application. A fully automated algorithm based on wavelet feature points and segment interpolation (AWFPSI) is proposed. This algorithm finds feature points through continuous wavelet transformation and estimates baseline through segment interpolation. AWFPSI is compared with three commonly introduced fully automated and semi-automated algorithms, using simulated spectrum signal, visible spectrum signal and Raman spectrum signal. The results show that AWFPSI gives better accuracy and has the advantage of easy use.

  4. 75 FR 67146 - New Postal Product

    Science.gov (United States)

    2010-11-01

    ... have the contract in Docket No. CP2010-71 serve as the baseline contract for future functional... GEPS 3 contracts fit within the Mail Classification Schedule language for the GEPS 3 product. The... incorporate the same cost attributes and methodology, the relevant characteristics of these six GEPS contracts...

  5. Quantification of baseline pupillary response and task-evoked pupillary response during constant and incremental task load.

    Science.gov (United States)

    Mosaly, Prithima R; Mazur, Lukasz M; Marks, Lawrence B

    2017-10-01

    The methods employed to quantify the baseline pupil size and task-evoked pupillary response (TEPR) may affect the overall study results. To test this hypothesis, the objective of this study was to assess variability in baseline pupil size and TEPR during two basic working memory tasks: constant load of 3-letters memorisation-recall (10 trials), and incremental load memorisation-recall (two trials of each load level), using two commonly used methods (1) change from trail/load specific baseline, (2) change from constant baseline. Results indicated that there was a significant shift in baseline between the trails for constant load, and between the load levels for incremental load. The TEPR was independent of shifts in baseline using method 1 only for constant load, and method 2 only for higher levels of incremental load condition. These important findings suggest that the assessment of both the baseline and methods to quantify TEPR are critical in ergonomics application, especially in studies with small number of trials per subject per condition. Practitioner Summary: Quantification of TEPR can be affected by shifts in baseline pupil size that are most likely affected by non-cognitive factors when other external factors are kept constant. Therefore, quantification methods employed to compute both baseline and TEPR are critical in understanding the information processing of humans in practical ergonomics settings.

  6. Baseline risk and marginal willingness to pay for health risk reduction.

    Science.gov (United States)

    Gerking, Shelby; Adamowicz, Wiktor; Dickie, Mark; Veronesi, Marcella

    2017-01-01

    Empirical results presented in this paper suggest that parents' marginal willingness to pay (MWTP) for a reduction in morbidity risk from heart disease is inversely related to baseline risk (i.e., the amount of risk initially faced) both for themselves and for their children. For instance, a 40% reduction from the mean of baseline risk results in an increase in MWTP by 70% or more. Thus, estimates of monetary benefits of public programs to reduce heart disease risk would be understated if the standard practice is followed of evaluating MWTP at initial risk levels and then multiplying this value by the number of cases avoided. Estimates are supported by: (1) unique quantitative information on perceptions of the risk of getting heart disease that allow baseline risk to be defined at an individual level and (2) improved econometric procedures to control for well-known difficulties associated with stated preference data.

  7. The relationship between psychological distress and baseline sports-related concussion testing.

    Science.gov (United States)

    Bailey, Christopher M; Samples, Hillary L; Broshek, Donna K; Freeman, Jason R; Barth, Jeffrey T

    2010-07-01

    This study examined the effect of psychological distress on neurocognitive performance measured during baseline concussion testing. Archival data were utilized to examine correlations between personality testing and computerized baseline concussion testing. Significantly correlated personality measures were entered into linear regression analyses, predicting baseline concussion testing performance. Suicidal ideation was examined categorically. Athletes underwent testing and screening at a university athletic training facility. Participants included 47 collegiate football players 17 to 19 years old, the majority of whom were in their first year of college. Participants were administered the Concussion Resolution Index (CRI), an internet-based neurocognitive test designed to monitor and manage both at-risk and concussed athletes. Participants took the Personality Assessment Inventory (PAI), a self-administered inventory designed to measure clinical syndromes, treatment considerations, and interpersonal style. Scales and subscales from the PAI were utilized to determine the influence psychological distress had on the CRI indices: simple reaction time, complex reaction time, and processing speed. Analyses revealed several significant correlations among aspects of somatic concern, depression, anxiety, substance abuse, and suicidal ideation and CRI performance, each with at least a moderate effect. When entered into a linear regression, the block of combined psychological symptoms accounted for a significant amount of baseline CRI performance, with moderate to large effects (r = 0.23-0.30). When examined categorically, participants with suicidal ideation showed significantly slower simple reaction time and complex reaction time, with a similar trend on processing speed. Given the possibility of obscured concussion deficits after injury, implications for premature return to play, and the need to target psychological distress outright, these findings heighten the clinical

  8. Accounting for baseline differences and measurement error in the analysis of change over time.

    Science.gov (United States)

    Braun, Julia; Held, Leonhard; Ledergerber, Bruno

    2014-01-15

    If change over time is compared in several groups, it is important to take into account baseline values so that the comparison is carried out under the same preconditions. As the observed baseline measurements are distorted by measurement error, it may not be sufficient to include them as covariate. By fitting a longitudinal mixed-effects model to all data including the baseline observations and subsequently calculating the expected change conditional on the underlying baseline value, a solution to this problem has been provided recently so that groups with the same baseline characteristics can be compared. In this article, we present an extended approach where a broader set of models can be used. Specifically, it is possible to include any desired set of interactions between the time variable and the other covariates, and also, time-dependent covariates can be included. Additionally, we extend the method to adjust for baseline measurement error of other time-varying covariates. We apply the methodology to data from the Swiss HIV Cohort Study to address the question if a joint infection with HIV-1 and hepatitis C virus leads to a slower increase of CD4 lymphocyte counts over time after the start of antiretroviral therapy. Copyright © 2013 John Wiley & Sons, Ltd.

  9. Patient baseline interpersonal problems as moderators of outcome in two psychotherapies for bulimia nervosa.

    Science.gov (United States)

    Gomez Penedo, Juan Martin; Constantino, Michael J; Coyne, Alice E; Bernecker, Samantha L; Smith-Hansen, Lotte

    2018-01-19

    We tested an aptitude by treatment interaction; namely, whether patients' baseline interpersonal problems moderated the comparative efficacy of cognitive-behavioral therapy (CBT) vs. interpersonal psychotherapy (IPT) for bulimia nervosa (BN). Data derived from a randomized-controlled trial. Patients reported on their interpersonal problems at baseline; purge frequency at baseline, midtreatment, and posttreatment; and global eating disorder severity at baseline and posttreatment. We estimated the rate of change in purge frequency across therapy, and the likelihood of attaining clinically meaningful improvement (recovery) in global eating disorder severity by posttreatment. We then tested the interpersonal problem by treatment interactions as predictors of both outcomes. Patients with more baseline overly communal/friendly problems showed steeper reduction in likelihood of purging when treated with CBT vs. IPT. Patients with more problems of being under communal/cold had similar reductions in likelihood of purging across both treatments. Patients with more baseline problems of being overly agentic were more likely to recover when treated with IPT vs. CBT, whereas patients with more problems of being under agentic were more likely to recover when treated with CBT vs. IPT. Interpersonal problems related to communion and agency may inform treatment fit among two empirically supported therapies for BN.

  10. A simple technique investigating baseline heterogeneity helped to eliminate potential bias in meta-analyses.

    Science.gov (United States)

    Hicks, Amy; Fairhurst, Caroline; Torgerson, David J

    2018-03-01

    To perform a worked example of an approach that can be used to identify and remove potentially biased trials from meta-analyses via the analysis of baseline variables. True randomisation produces treatment groups that differ only by chance; therefore, a meta-analysis of a baseline measurement should produce no overall difference and zero heterogeneity. A meta-analysis from the British Medical Journal, known to contain significant heterogeneity and imbalance in baseline age, was chosen. Meta-analyses of baseline variables were performed and trials systematically removed, starting with those with the largest t-statistic, until the I 2 measure of heterogeneity became 0%, then the outcome meta-analysis repeated with only the remaining trials as a sensitivity check. We argue that heterogeneity in a meta-analysis of baseline variables should not exist, and therefore removing trials which contribute to heterogeneity from a meta-analysis will produce a more valid result. In our example none of the overall outcomes changed when studies contributing to heterogeneity were removed. We recommend routine use of this technique, using age and a second baseline variable predictive of outcome for the particular study chosen, to help eliminate potential bias in meta-analyses. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Could baseline establishment be counterproductive for emissions reduction? Insights from Vietnam’s building sector

    DEFF Research Database (Denmark)

    Henrysson, Maryna; Lütken, Søren; Puig, Daniel

    2017-01-01

    Mitigation Actions (NAMAs) to illustrate institutional dynamics, nationally and transnationally, as well as to question whether demands for baseline setting achieve the ideal trade-off between actual GHG emissions reduction and institutionalized demands for accountability. The analysis reveals that......, it argues for the abolition of baselines in favour of adequate monitoring and evaluation, from the perspective that requirement for deviation from fictitious baselines is unproductive and only serves an international techno-managerial discourse....

  12. BASLIKO. A program for baseline-correction of earthquake-accelerograms

    International Nuclear Information System (INIS)

    Koschmieder, D.; Altes, J.

    1978-12-01

    In the following report a program for baseline-correction of earthquake-accelerograms is presented. By using this program errors in curves, which occur in using the chronographs and digitizers, are eliminated. (orig.) [de

  13. Effects of harvest time on production and chemical evolution of Jerusalem artichoke (Helianthus tuberosus L.) cultivated in the Mediterranean area

    Energy Technology Data Exchange (ETDEWEB)

    Losavio, N.; Ventrella, D.; Lamascese, N.; Vonella, A.V. [Istituto Sperimentale Agronimico, Bari (Italy)

    1997-07-01

    The purpose of this paper is to determine the optimum harvest time and to evaluate biomass and sugar production of a Jerusalem artichoke crop. Field trials were conducted during 1994 and 1995 at Metaponto (MT) in southern Italy (lat. 40{sup o} 24'N; long. 16{sup o} 48' E) on clay loam soil (Typic Epiaquerts in accordance with soil taxonomy). In both years tubers were planted at the end of March with a density of 7.4 plants m{sup -2} (0.45 m rows spacing). The Jerusalem artichoke crop (cv. ''Violette de Rennes'') was irrigated during the whole growing cycle by re-establishment of 50% maximum evapotranspiration on the basis of agrometeorological data. Tubers and stalks were harvested at a plant height of 0.25 and 0.5 m; 40 and 20 days before flowering stage; at flowering stage; and at physiological maturity stage. Tubers and stalks were analyzed for fresh and dry matter weight, and for fructose and glucose contents determined by the Samogyi-Nelsen method. Our observations show that the best harvest times were at flowering stage (for stalk production) and at physiological maturity stage (for tuber production). (author)

  14. High baseline activity in inferior temporal cortex improves neural and behavioral discriminability during visual categorization

    Directory of Open Access Journals (Sweden)

    Nazli eEmadi

    2014-11-01

    Full Text Available Spontaneous firing is a ubiquitous property of neural activity in the brain. Recent literature suggests that this baseline activity plays a key role in perception. However, it is not known how the baseline activity contributes to neural coding and behavior. Here, by recording from the single neurons in the inferior temporal cortex of monkeys performing a visual categorization task, we thoroughly explored the relationship between baseline activity, the evoked response, and behavior. Specifically we found that a low-frequency (< 8 Hz oscillation in the spike train, prior and phase-locked to the stimulus onset, was correlated with increased gamma power and neuronal baseline activity. This enhancement of the baseline activity was then followed by an increase in the neural selectivity and the response reliability and eventually a higher behavioral performance.

  15. Spectrometer Baseline Control Via Spatial Filtering

    Science.gov (United States)

    Burleigh, M. R.; Richey, C. R.; Rinehart, S. A.; Quijada, M. A.; Wollack, E. J.

    2016-01-01

    An absorptive half-moon aperture mask is experimentally explored as a broad-bandwidth means of eliminating spurious spectral features arising from reprocessed radiation in an infrared Fourier transform spectrometer. In the presence of the spatial filter, an order of magnitude improvement in the fidelity of the spectrometer baseline is observed. The method is readily accommodated within the context of commonly employed instrument configurations and leads to a factor of two reduction in optical throughput. A detailed discussion of the underlying mechanism and limitations of the method are provided.

  16. Neutrino physics with short baseline experiments

    International Nuclear Information System (INIS)

    Zimmerman, E.D.

    2006-01-01

    Neutrino physics with low- to medium-energy beams has progressed steadily over the last several years. Neutrino oscillation searches at short baseline (defined as 2 - -> 0.1eV 2 . One positive signal, from the LSND collaboration, exists and is being tested by the MiniBooNE experiment. Neutrino cross-section measurements are being made by MiniBooNE and K2K, which will be important for reducing systematic errors in present and future oscillation measurements. In the near future, dedicated cross- section experiments will begin operating at Fermilab. (author)

  17. Environmental Baseline File for National Transportation

    International Nuclear Information System (INIS)

    1999-01-01

    This Environmental Baseline File summarizes and consolidates information related to the national-level transportation of commercial spent nuclear fuel. Topics address include: shipments of commercial spent nuclear fuel based on mostly truck and mostly rail shipping scenarios; transportation routing for commercial spent nuclear fuel sites and DOE sites; radionuclide inventories for various shipping container capacities; transportation routing; populations along transportation routes; urbanized area population densities; the impacts of historical, reasonably foreseeable, and general transportation; state-level food transfer factors; Federal Guidance Report No. 11 and 12 radionuclide dose conversion factors; and national average atmospheric conditions

  18. New baseline correction algorithm for text-line recognition with bidirectional recurrent neural networks

    Science.gov (United States)

    Morillot, Olivier; Likforman-Sulem, Laurence; Grosicki, Emmanuèle

    2013-04-01

    Many preprocessing techniques have been proposed for isolated word recognition. However, recently, recognition systems have dealt with text blocks and their compound text lines. In this paper, we propose a new preprocessing approach to efficiently correct baseline skew and fluctuations. Our approach is based on a sliding window within which the vertical position of the baseline is estimated. Segmentation of text lines into subparts is, thus, avoided. Experiments conducted on a large publicly available database (Rimes), with a BLSTM (bidirectional long short-term memory) recurrent neural network recognition system, show that our baseline correction approach highly improves performance.

  19. S Plant Aggregate Area Management study technical baseline report

    International Nuclear Information System (INIS)

    DeFord, D.H.; Carpenter, R.W.

    1995-05-01

    This document is prepared in support of an Aggregate Area Management Study of S Plant, 200 West Area, at the US Department of Energy's (DOE) Hanford Site near Richland, Washington. It provides a technical baseline of the aggregate area and the results from an environmental investigation undertaken by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (WHC). This document is based on review and evaluation of numerous Hanford Site current and historical reports, drawings and photographs, supplemented with site inspections and employee interviews. This report describes the REDOX facility and its waste sites, including cribs, french drains, septic tanks and drain fields, trenches, catch tanks, settling tanks, diversion boxes, underground tank farms designed for high-level liquid wastes, and the lines and encasements that connect them

  20. Measurement of baseline and orientation between distributed aerospace platforms.

    Science.gov (United States)

    Wang, Wen-Qin

    2013-01-01

    Distributed platforms play an important role in aerospace remote sensing, radar navigation, and wireless communication applications. However, besides the requirement of high accurate time and frequency synchronization for coherent signal processing, the baseline between the transmitting platform and receiving platform and the orientation of platform towards each other during data recording must be measured in real time. In this paper, we propose an improved pulsed duplex microwave ranging approach, which allows determining the spatial baseline and orientation between distributed aerospace platforms by the proposed high-precision time-interval estimation method. This approach is novel in the sense that it cancels the effect of oscillator frequency synchronization errors due to separate oscillators that are used in the platforms. Several performance specifications are also discussed. The effectiveness of the approach is verified by simulation results.

  1. Esophageal Baseline Impedance Reflects Mucosal Integrity and Predicts Symptomatic Outcome With Proton Pump Inhibitor Treatment.

    Science.gov (United States)

    Xie, Chenxi; Sifrim, Daniel; Li, Yuwen; Chen, Minhu; Xiao, Yinglian

    2018-01-30

    Esophageal baseline impedance, which is decreased in gastroesophageal reflux disease (GERD) patients, is related to the severity of acid reflux and the integrity of the esophageal mucosa. The study aims to compare the baseline impedance and the dilated intercellular spaces (DIS) within patients with typical reflux symptoms and to evaluate the correlation of baseline impedance with DIS, esophageal acid exposure, as well as the efficacy of proton pump inhibitor (PPI) treatment. Ninety-two patients and 10 healthy controls were included in the study. Erosive esophagitis (EE) was defined by esophageal mucosal erosion under upper endoscopy. Patients without mucosa erosion were divided into groups with pathologic acid reflux (non-erosive reflux disease [NERD]) or with hypersensitive esophagus. The biopsies of esophageal mucosa were taken 2-4 cm above the gastroesophageal junction Z-line during upper endoscopy for DIS measurement. All the patients received esomeprazole 20 mg twice-daily treatment for 8 weeks. The efficacy of esomeprazole was evaluated among all patients. The intercellular spaces were dilated in both EE and NERD patients ( P baseline impedance was decreased in both EE patients and NERD patients, and negatively correlated to the acid exposure time ( r = -0.527, P baseline impedance ( r = -0.230, P Baseline impedance > 1764 Ω" was an independent predictor for PPI failure (OR, 11.9; 95% CI, 2.4-58.9; P baseline impedance was observed in patients with mucosa erosion or pathological acid reflux. The baseline impedance reflected the mucosal integrity, it was more sensitive to esophageal acid exposure. Patients with high impedance might not benefit from the PPI treatment.

  2. A baseline correction algorithm for Raman spectroscopy by adaptive knots B-spline

    International Nuclear Information System (INIS)

    Wang, Xin; Fan, Xian-guang; Xu, Ying-jie; Wang, Xiu-fen; He, Hao; Zuo, Yong

    2015-01-01

    The Raman spectroscopy technique is a powerful and non-invasive technique for molecular fingerprint detection which has been widely used in many areas, such as food safety, drug safety, and environmental testing. But Raman signals can be easily corrupted by a fluorescent background, therefore we presented a baseline correction algorithm to suppress the fluorescent background in this paper. In this algorithm, the background of the Raman signal was suppressed by fitting a curve called a baseline using a cyclic approximation method. Instead of the traditional polynomial fitting, we used the B-spline as the fitting algorithm due to its advantages of low-order and smoothness, which can avoid under-fitting and over-fitting effectively. In addition, we also presented an automatic adaptive knot generation method to replace traditional uniform knots. This algorithm can obtain the desired performance for most Raman spectra with varying baselines without any user input or preprocessing step. In the simulation, three kinds of fluorescent background lines were introduced to test the effectiveness of the proposed method. We showed that two real Raman spectra (parathion-methyl and colza oil) can be detected and their baselines were also corrected by the proposed method. (paper)

  3. 77 FR 23244 - Atmos Energy Colorado/Kansas Division; Notice of Revised Baseline Filing

    Science.gov (United States)

    2012-04-18

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR12-22-000] Atmos Energy Colorado/Kansas Division; Notice of Revised Baseline Filing Take notice that on April 10, 2012, Atmos Energy Colorado/Kansas Division (Atmos) filed a revised baseline filing of their Statement of Operating...

  4. 76 FR 2361 - Atmos Energy-Kentucky/Mid-States Division; Notice of Baseline Filing

    Science.gov (United States)

    2011-01-13

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR11-77-000] Atmos Energy--Kentucky/Mid-States Division; Notice of Baseline Filing January 5, 2011. Take notice that on December 30, 2010, Atmos Energy--Kentucky/Mid- States Division submitted a revised baseline filing of their...

  5. Contribution of BeiDou satellite system for long baseline GNSS measurement in Indonesia

    Science.gov (United States)

    Gumilar, I.; Bramanto, B.; Kuntjoro, W.; Abidin, H. Z.; Trihantoro, N. F.

    2018-05-01

    The demand for more precise positioning method using GNSS (Global Navigation Satellite System) in Indonesia continue to rise. The accuracy of GNSS positioning depends on the length of baseline and the distribution of observed satellites. BeiDou Navigation Satellite System (BDS) is a positioning system owned by China that operating in Asia-Pacific region, including Indonesia. This research aims to find out the contribution of BDS in increasing the accuracy of long baseline static positioning in Indonesia. The contributions are assessed by comparing the accuracy of measurement using only GPS (Global Positioning System) and measurement using the combination of GPS and BDS. The data used is 5 days of GPS and BDS measurement data for baseline with 120 km in length. The software used is open-source RTKLIB and commercial software Compass Solution. This research will explain in detail the contribution of BDS to the accuracy of position in long baseline static GNSS measurement.

  6. Reestablishment of Notopygos megalops McIntosh, description of N. caribea sp. n. from the Greater Caribbean and barcoding of “amphiamerican” Notopygos species (Annelida, Amphinomidae)

    Science.gov (United States)

    Yáñez-Rivera, Beatriz; Carrera-Parra, Luis Fernando

    2012-01-01

    Abstract The species of the genus Notopygos Grube, 1855 are characterized by an ovate body, a prominent caruncle with three lobes, dendritic branchiae, and double dorsal cirri. Twenty-two species belonging to Notopygos have been described, mostly from the Indo-Pacific region. In America, few species are frequently recorded: Notopygos crinita Grube, 1855 from St. Helena Island (Atlantic) and Notopygos ornata Grube and Ørsted in Grube 1857 from Costa Rica (Pacific). Notopygos crinita is a widely distributed species in the Western Atlantic with additional reports in the Mediterranean Sea (as a questionable alien species) and in the Pacific Ocean. However, only the genus features have been considered, consequently some records could be misidentifications. During a revision of materials from collections and the barcode project, ‘Mexican Barcode of Life, MEXBOL’, we found specimens of Notopygos megalops and an undescribed species from reef zones in the Caribbean; the former had been considered a junior synonym of Notopygos crinita. Herein, Notopygos megalops is reestablished and Notopygos caribea sp. n. is described. A morphological and DNA barcode approach was used to explain the records of Notopygos ornata in the Atlantic and to show the differences with the new species, since both species share features such as complex pigmentation patterns, and circular projections in the median lobe of the caruncle. PMID:23459182

  7. Reestablishment of Notopygos megalops McIntosh, description of N. caribea sp. n. from the Greater Caribbean and barcoding of “amphiamerican” Notopygos species (Annelida, Amphinomidae

    Directory of Open Access Journals (Sweden)

    Beatriz Yanez

    2012-09-01

    Full Text Available The species of the genus Notopygos Grube, 1855 are characterized by an ovate body, a prominent caruncle with three lobes, dendritic branchiae, and double dorsal cirri. Twenty-two species belonging to Notopygos have been described, mostly from the Indo-Pacific region. In America, few species are frequently recorded: N. crinita Grube, 1855 from St. Helena Island (Atlantic and N. ornata Grube and Ørsted in Grube 1857 from Costa Rica (Pacific. Notopygos crinita is a widely distributed species in the Western Atlantic with additional reports in the Mediterranean Sea (as a questionable alien species and in the Pacific Ocean. However, only the genus features have been considered, consequently some records could be misidentifications. During a revision of materials from collections and the barcode project, ‘Mexican Barcode of Life, MEXBOL’, we found specimens of N. megalops and an undescribed species from reef zones in the Caribbean; the former had been considered a junior synonym of N. crinita. Herein, N. megalops is reestablished and N. caribea sp. n. is described. A morphological and DNA barcode approach was used to explain the records of N. ornata in the Atlantic and to show the differences with the new species, since both species share features such as complex pigmentation patterns, and circular projections in the median lobe of the caruncle.

  8. Baseline disability in activities of daily living predicts dementia risk even after controlling for baseline global cognitive ability and depressive symptoms.

    Science.gov (United States)

    Fauth, Elizabeth B; Schwartz, Sarah; Tschanz, Joann T; Østbye, Truls; Corcoran, Christopher; Norton, Maria C

    2013-06-01

    Late-life disability in activities of daily living (ADL) is theorized to be driven by underlying cognitive and/or physical impairment, interacting with psychological and environmental factors. Although we expect that cognitive deficits would explain associations between ADL disability and dementia risk, the current study examined ADL as a predictor of future dementia after controlling for global cognitive status. The population-based Cache County Memory Study (N = 3547) assessed individuals in four triennial waves (average age 74.9 years, years of education 13.36 years; 57.9% were women). Cox proportional hazards regression models assessed whether baseline ADL disability (presence of 2+ Instrumental ADL and/or 1+ Personal ADL) predicted incident dementia after controlling for APOE status, gender, age, baseline cognitive ability (Modified Mini-mental State Exam, 3MS-R; adjusted for education level), and baseline depressive symptoms (Diagnostic Interview Schedule). Over the course of study, 571 cases of incident dementia were identified through in-depth cognitive assessment, ending in expert consensus diagnosis. Results from Cox models suggest that ADL disability is a statistically significant predictor of incident dementia (adjusted hazard ratio = 1.83, p controlling for covariates. Findings suggest that ADL disability offers unique contributions in risk for incident dementia, even after controlling for global cognitive status. We discuss how physical impairment and executive function may play important roles in this relationship, and how ADL is useful, not just a diagnostic tool at, or after dementia onset, but also as a risk factor for future dementia, even in individuals not impaired on global cognitive tests. Copyright © 2012 John Wiley & Sons, Ltd.

  9. The effect of baseline testosterone on the efficacy of degarelix and leuprolide

    DEFF Research Database (Denmark)

    Damber, Jan-Erik; Tammela, Teuvo L J; Iversen, Peter

    2012-01-01

    To investigate the effects of baseline testosterone on testosterone control and prostate-specific antigen (PSA) suppression using data from a phase III trial (CS21) comparing degarelix and leuprolide in prostate cancer.......To investigate the effects of baseline testosterone on testosterone control and prostate-specific antigen (PSA) suppression using data from a phase III trial (CS21) comparing degarelix and leuprolide in prostate cancer....

  10. The Role of Cryptococcus in the Immune System of Pulmonary Cryptococcosis Patients.

    Directory of Open Access Journals (Sweden)

    Jinlin Wang

    Full Text Available To investigate the role of Cryptococcus in the immune system of immunocompetent patients with pulmonary cryptococcosis (PC by analysing the dynamic changes of patients' immune status before and after antifungal therapy.The level of the serum interferon-γ (IFN-γ and interleukin (IL-2, -4, -10 and -12 was measured before and after 6-months of treatment. Peripheral blood samples were obtained from 30 immunocompetent PC patients and 30 age- and gender-matched healthy controls. Peripheral blood mononuclear cells (PBMCs were isolated and incubated with recombinant human IL-12 (rhIL-12 for 48 h. Then the concentrations of IFN-γ and IL-4 in the supernatant were analysed.Baseline serum IFN-γ level was significantly lower in the PC patients as compared with the control group (P < 0.001. The serum IL-2 and IFN-γ of PC patients were significantly increased after appropriate treatments (P < 0.05 and P < 0.001 when compared to their baseline levels. The productions of IFN-γ in the culture supernatant of PBMCs showed no significant difference between the control and PC patients both before and after antifungal treatments. RhIL-12 is a potent stimulus for IFN-γ production. Culture PBMCs collected from PC patients before treatments had a smaller increase of IFN-γ production in the present of rhIL-12 than the control (P < 0.01; PBMCs from PC patients completing 6-months of treatment showed a comparable increase of IFN-γ production by rhIL-12 stimulation to the control group.In apparently immunocompetent patients with PC, a normalization of serum IFN-γ was achieved after recovery from infection. This suggests that Cryptococcus infection per se can suppress the immune system and its elimination contributes to the reestablishment of an immune equilibrium.

  11. The baseline pressure of intracranial pressure (ICP) sensors can be altered by electrostatic discharges.

    Science.gov (United States)

    Eide, Per K; Bakken, André

    2011-08-22

    The monitoring of intracranial pressure (ICP) has a crucial role in the surveillance of patients with brain injury. During long-term monitoring of ICP, we have seen spontaneous shifts in baseline pressure (ICP sensor zero point), which are of technical and not physiological origin. The aim of the present study was to explore whether or not baseline pressures of ICP sensors can be affected by electrostatics discharges (ESD's), when ESD's are delivered at clinically relevant magnitudes. We performed bench-testing of a set of commercial ICP sensors. In our experimental setup, the ICP sensor was placed in a container with 0.9% NaCl solution. A test person was charged 0.5-10 kV, and then delivered ESD's to the sensor by touching a metal rod that was located in the container. The continuous pressure signals were recorded continuously before/after the ESD's, and the pressure readings were stored digitally using a computerized system A total of 57 sensors were tested, including 25 Codman ICP sensors and 32 Raumedic sensors. When charging the test person in the range 0.5-10 kV, typically ESD's in the range 0.5-5 kV peak pulse were delivered to the ICP sensor. Alterations in baseline pressure ≥ 2 mmHg was seen in 24 of 25 (96%) Codman sensors and in 17 of 32 (53%) Raumedic sensors. Lasting changes in baseline pressure > 10 mmHg that in the clinical setting would affect patient management, were seen frequently for both sensor types. The changes in baseline pressure were either characterized by sudden shifts or gradual drifts in baseline pressure. The baseline pressures of commercial solid ICP sensors can be altered by ESD's at discharge magnitudes that are clinically relevant. Shifts in baseline pressure change the ICP levels visualised to the physician on the monitor screen, and thereby reveal wrong ICP values, which likely represent a severe risk to the patient.

  12. [Diagnostic value of baseline serum luteinizing hormone level for central precocious puberty in girls].

    Science.gov (United States)

    Ou-Yang, Li-Xue; Yang, Fan

    2017-07-01

    To evaluate the diagnostic value of baseline serum luteinizing hormone (LH) level for central precocious puberty (CPP) in girls. A total of 279 girls with precocious puberty were subjected to assessment of growth and development, bone age determination, baseline LH test, and follicle-stimulating hormone (FSH) test, gonadotropin-releasing hormone stimulation test, and other related examinations. Of the 279 patients, 175 were diagnosed with CPP and 104 with premature thelarche (PT). The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic value of baseline LH and FSH levels and their peak levels for CPP, and the correlation between the baseline LH level and the peak LH level was analyzed. The CPP group had significantly higher bone age, baseline LH and FSH levels, peak LH and FSH levels, and ratio of peak LH level to peak FSH level than the PT group (Pbaseline LH level and peak LH level had good diagnostic values for CPP. Among the three bone age subgroups in the CPP group (7.0-9.0 years, 9.0-11.0 years, and >11.0 years), baseline LH level showed the best diagnostic value in the >11.0 years subgroup, with the largest area under the ROC curve. At a baseline LH level of 0.45 IU/L, the Youden index reached the peak value, and the sensitivity and specificity were 66.7% and 80% respectively, for the diagnosis of CPP. At a peak LH level of 9.935 IU/L, the Youden index reached the peak value, and the sensitivity and specificity were 74.8% and 100% respectively, for the diagnosis of CPP. The baseline LH level was positively correlated with the peak LH level (r=0.440, PBaseline LH level can be used as an primary screening index for the diagnosis of CPP. It has a certain diagnostic value for CPP at different bone ages, and may be used as a monitoring index during the treatment and follow-uP.

  13. Evaluation of the accuracy of estimated baseline serum creatinine for acute kidney injury diagnosis.

    Science.gov (United States)

    Hatakeyama, Yutaka; Horino, Taro; Nagata, Keitaro; Kataoka, Hiromi; Matsumoto, Tatsuki; Terada, Yoshio; Okuhara, Yoshiyasu

    2018-04-01

    Modern epidemiologic studies of acute kidney injury (AKI) have been facilitated by the increasing availability of electronic medical records. However, pre-morbid reference serum creatinine (SCr) data are often unavailable in such records. Investigators substitute estimated baseline SCr with the eGFR 75 approach, instead of using actually measured baseline SCr. Here, we evaluated the accuracy of estimated baseline SCr for AKI diagnosis in the Japanese population. Inpatients and outpatients aged 18-80 years were retrospectively enrolled. AKI was diagnosed according to the Kidney Disease Improving Global Outcomes (KDIGO) criteria, using SCr levels. The non-AKI and AKI groups were selected using the following criteria: increase 1.5 times greater than baseline SCr ("baseline SCr") or increase 0.3 mg/dL greater than baseline SCr in 48 h ("increase in 48 h"). AKI accuracy defined by the estimated reference SCr, the average SCr value of the non-AKI population (eb-GFR-A approach), or the back-calculated SCr from fixed eGFR = 75 mL/min/1.73 m 2 (eGFR 75 approach, or, eb-GFR-B approach in this study), was evaluated. We analyzed data from 131,358 Japanese patients. The number of patients with reference baseline SCr in the non-AKI and AKI patients were 29,834 and 8952, respectively. For AKI patients diagnosed using "baseline SCr", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 63.5 and 57.7%, respectively, while in AKI diagnosed using "increase in 48 h", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 78.7 and 75.1%, respectively. In non-AKI patients, false-positive rates of AKI misdiagnosed via eb-GFR-A and eb-GFR-B were 7.4 and 6.8%, respectively. AKI diagnosis using the average SCr value of the general population may yield more accurate results than diagnosis using the eGFR 75 approach when the reference SCr is unavailable.

  14. Baseline response rates affect resistance to change.

    Science.gov (United States)

    Kuroda, Toshikazu; Cook, James E; Lattal, Kennon A

    2018-01-01

    The effect of response rates on resistance to change, measured as resistance to extinction, was examined in two experiments. In Experiment 1, responding in transition from a variable-ratio schedule and its yoked-interval counterpart to extinction was compared with pigeons. Following training on a multiple variable-ratio yoked-interval schedule of reinforcement, in which response rates were higher in the former component, reinforcement was removed from both components during a single extended extinction session. Resistance to extinction in the yoked-interval component was always either greater or equal to that in the variable-ratio component. In Experiment 2, resistance to extinction was compared for two groups of rats that exhibited either high or low response rates when maintained on identical variable-interval schedules. Resistance to extinction was greater for the lower-response-rate group. These results suggest that baseline response rate can contribute to resistance to change. Such effects, however, can only be revealed when baseline response rate and reinforcement rate are disentangled (Experiments 1 and 2) from the more usual circumstance where the two covary. Furthermore, they are more cleanly revealed when the programmed contingencies controlling high and low response rates are identical, as in Experiment 2. © 2017 Society for the Experimental Analysis of Behavior.

  15. Integrated Baseline Review (IBR) Handbook

    Science.gov (United States)

    Fleming, Jon F.; Kehrer, Kristen C.

    2016-01-01

    The purpose of this handbook is intended to be a how-to guide to prepare for, conduct, and close-out an Integrated Baseline Review (IBR). It discusses the steps that should be considered, describes roles and responsibilities, tips for tailoring the IBR based on risk, cost, and need for management insight, and provides lessons learned from past IBRs. Appendices contain example documentation typically used in connection with an IBR. Note that these appendices are examples only, and should be tailored to meet the needs of individual projects and contracts. Following the guidance in this handbook will help customers and suppliers preparing for an IBR understand the expectations of the IBR, and ensure that the IBR meets the requirements for both in-house and contract efforts.

  16. Early antihypertensive treatment and clinical outcomes in acute ischemic stroke: subgroup analysis by baseline blood pressure.

    Science.gov (United States)

    He, William J; Zhong, Chongke; Xu, Tan; Wang, Dali; Sun, Yingxian; Bu, Xiaoqing; Chen, Chung-Shiuan; Wang, Jinchao; Ju, Zhong; Li, Qunwei; Zhang, Jintao; Geng, Deqin; Zhang, Jianhui; Li, Dong; Li, Yongqiu; Yuan, Xiaodong; Zhang, Yonghong; Kelly, Tanika N

    2018-06-01

    We studied the effect of early antihypertensive treatment on death, major disability, and vascular events among patients with acute ischemic stroke according to their baseline SBP. We randomly assigned 4071 acute ischemic stroke patients with SBP between 140 and less than 220 mmHg to receive antihypertensive treatment or to discontinue all antihypertensive medications during hospitalization. A composite primary outcome of death and major disability and secondary outcomes were compared between treatment and control stratified by baseline SBP levels of less than 160, 160-179, and at least 180 mmHg. At 24 h after randomization, differences in SBP reductions were 8.8, 8.6 and 7.8 mmHg between the antihypertensive treatment and control groups among patients with baseline SBP less than 160, 160-179, and at least 180 mmHg, respectively (P baseline SBP subgroups on death (P = 0.02): odds ratio (95% CI) of 2.42 (0.74-7.89) in patients with baseline SBP less than 60 mmHg and 0.34 (0.11-1.09) in those with baseline SBP at least 180 mmHg. At the 3-month follow-up, the primary and secondary clinical outcomes were not significantly different between the treatment and control groups by baseline SBP levels. Early antihypertensive treatment had a neutral effect on clinical outcomes among acute ischemic stroke patients with various baseline SBP levels. Future clinical trials are warranted to test BP-lowering effects in acute ischemic stroke patients by baseline SBP levels. ClinicalTrials.gov Identifier: NCT01840072.

  17. 75 FR 26746 - ONEOK Westex Transmission, L.L.C.; Notice of Baseline Filing

    Science.gov (United States)

    2010-05-12

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-19-000] ONEOK Westex Transmission, L.L.C.; Notice of Baseline Filing May 5, 2010. Take notice that on April 29, 2010, ONEOK Westex Transmission, L.L.C. submitted its baseline filing of its Statement of Operating Conditions for transportation...

  18. Influence of Baseline Diastolic Blood Pressure on Effects of Intensive Compared With Standard Blood Pressure Control.

    Science.gov (United States)

    Beddhu, Srinivasan; Chertow, Glenn M; Cheung, Alfred K; Cushman, William C; Rahman, Mahboob; Greene, Tom; Wei, Guo; Campbell, Ruth C; Conroy, Margaret; Freedman, Barry I; Haley, William; Horwitz, Edward; Kitzman, Dalane; Lash, James; Papademetriou, Vasilios; Pisoni, Roberto; Riessen, Erik; Rosendorff, Clive; Watnick, Suzanne G; Whittle, Jeffrey; Whelton, Paul K

    2018-01-09

    In individuals with a low diastolic blood pressure (DBP), the potential benefits or risks of intensive systolic blood pressure (SBP) lowering are unclear. SPRINT (Systolic Blood Pressure Intervention Trial) was a randomized controlled trial that compared the effects of intensive (target baseline DBP. Mean baseline SBP and DBP were 139.7±15.6 and 78.1±11.9 mm Hg, respectively. Regardless of the randomized treatment, baseline DBP had a U-shaped association with the hazard of the primary cardiovascular disease outcome. However, the effects of the intensive SBP intervention on the primary outcome were not influenced by baseline DBP level ( P for interaction=0.83). The primary outcome hazard ratio for intensive versus standard treatment was 0.78 (95% confidence interval, 0.57-1.07) in the lowest DBP quintile (mean baseline DBP, 61±5 mm Hg) and 0.74 (95% confidence interval, 0.61-0.90) in the upper 4 DBP quintiles (mean baseline DBP, 82±9 mm Hg), with an interaction P value of 0.78. Results were similar for all-cause death and kidney events. Low baseline DBP was associated with increased risk of cardiovascular disease events, but there was no evidence that the benefit of the intensive SBP lowering differed by baseline DBP. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01206062. © 2017 American Heart Association, Inc.

  19. Assessment of local GNSS baselines at co-location sites

    Science.gov (United States)

    Herrera Pinzón, Iván; Rothacher, Markus

    2018-01-01

    As one of the major contributors to the realisation of the International Terrestrial Reference System (ITRS), the Global Navigation Satellite Systems (GNSS) are prone to suffer from irregularities and discontinuities in time series. While often associated with hardware/software changes and the influence of the local environment, these discrepancies constitute a major threat for ITRS realisations. Co-located GNSS at fundamental sites, with two or more available instruments, provide the opportunity to mitigate their influence while improving the accuracy of estimated positions by examining data breaks, local biases, deformations, time-dependent variations and the comparison of GNSS baselines with existing local tie measurements. With the use of co-located GNSS data from a subset sites of the International GNSS Service network, this paper discusses a global multi-year analysis with the aim of delivering homogeneous time series of coordinates to analyse system-specific error sources in the local baselines. Results based on the comparison of different GNSS-based solutions with the local survey ties show discrepancies of up to 10 mm despite GNSS coordinate repeatabilities at the sub-mm level. The discrepancies are especially large for the solutions using the ionosphere-free linear combination and estimating tropospheric zenith delays, thus corresponding to the processing strategy used for global solutions. Snow on the antennas causes further problems and seasonal variations of the station coordinates. These demonstrate the need for a permanent high-quality monitoring of the effects present in the short GNSS baselines at fundamental sites.

  20. Increase in work productivity of depressed individuals with improvement in depressive symptom severity.

    Science.gov (United States)

    Trivedi, Madhukar H; Morris, David W; Wisniewski, Stephen R; Lesser, Ira; Nierenberg, Andrew A; Daly, Ella; Kurian, Benji T; Gaynes, Bradley N; Balasubramani, G K; Rush, A John

    2013-06-01

    The authors sought to identify baseline clinical and sociodemographic characteristics associated with work productivity in depressed outpatients and to assess the effect of treatment on work productivity. Employed depressed outpatients 18-75 years old who completed the Work Productivity and Activity Impairment scale (N=1,928) were treated with citalopram (20-40 mg/day) in the Sequenced Treatment Alternatives to Relieve Depression study. For patients who did not remit after an initial adequate antidepressant trial (level 1), either a switch to sertraline, sustained-release bupropion, or extended-release venlafaxine or an augmentation with sustained-release bupropion or buspirone was provided (level 2). Participants' clinical and demographic characteristics and treatment outcomes were analyzed for associations with baseline work productivity and change in productivity over time. Education, baseline depression severity, and melancholic, atypical, and recurrent depression subtypes were all independently associated with lower benefit to work productivity domains. During level 1 treatment, work productivity in several domains improved with reductions in depressive symptom severity. However, these findings did not hold true for level 2 outcomes; there was no significant association between treatment response and reduction in work impairment. Results were largely confirmed when multiple imputations were employed to address missing data. During this additional analysis, an association was also observed between greater impairment in work productivity and higher levels of anxious depression. Patients with clinically significant reductions in symptom severity during initial treatment were more likely than nonresponders to experience significant improvements in work productivity. In contrast, patients who achieved symptom remission in second-step treatment continued to have impairment at work. Patients who have demonstrated some degree of treatment resistance are more prone to

  1. Baseline drift effect on the performance of neutron and γ ray discrimination using frequency gradient analysis

    International Nuclear Information System (INIS)

    Liu Guofu; Luo Xiaoliang; Yang Jun; Lin Cunbao; Hu Qingqing; Peng Jinxian

    2013-01-01

    Frequency gradient analysis (FGA) effectively discriminates neutrons and γ rays by examining the frequency-domain features of the photomultiplier tube anode signal. This approach is insensitive to noise but is inevitably affected by the baseline drift similar to other pulse shape discrimination methods. The baseline drift effect is attributed to factors such as power line fluctuation, dark current, noise disturbances, hum, and pulse tail in front-end electronics. This effect needs to be elucidated and quantified before the baseline shift can be estimated and removed from the captured signal. Therefore, the effect of baseline shift on the discrimination performance of neutrons and γ rays with organic scintillation detectors using FGA is investigated in this paper. The relationship between the baseline shift and discrimination parameters of FGA is derived and verified by an experimental system consisting of an americium—beryllium source, a BC501A liquid scintillator detector, and a 5 GSample/s 8-bit oscilloscope. The theoretical and experimental results both show that the estimation of the baseline shift is necessary, and the removal of baseline drift from the pulse shapes can improve the discrimination performance of FGA. (authors)

  2. Baseline and annual repeat rounds of screening. Implications for optimal regimens of screening

    Energy Technology Data Exchange (ETDEWEB)

    Henschke, Claudia I.; Salvatore, Mary; Cham, Matthew; Eber, Corey; Yip, Rowena; Yankelevitz, David F. [Icahn School of Medicine at Mount Sinai, Department of Radiology, New York, NY (United States); Powell, Charles A.; DiFabrizio, Larry [Icahn School of Medicine at Mount Sinai, Department of Medicine, New York, NY (United States); Flores, Raja; Kaufman, Andrew [Icahn School of Medicine at Mount Sinai, Department of Thoracic Surgery, New York, NY (United States); Collaboration: International Early Lung Cancer Action Program Investigators

    2018-03-15

    Differences in results of baseline and subsequent annual repeat rounds provide important information for optimising the regimen of screening. A prospective cohort study of 65,374 was reviewed to examine the frequency/percentages of the largest noncalcified nodule (NCN), lung cancer cell types and Kaplan-Meier (K-M) survival rates, separately for baseline and annual rounds. Of 65,374 baseline screenings, NCNs were identified in 28,279 (43.3%); lung cancer in 737 (1.1%). Of 74,482 annual repeat screenings, new NCNs were identified in 4959 (7%); lung cancer in 179 (0.24%). Only adenocarcinoma was diagnosed in subsolid NCNs. Percentages of lung cancers by cell type were significantly different (p < 0.0001) in the baseline round compared with annual rounds, reflecting length bias, as were the ratios, reflecting lead times. Long-term K-M survival rate was 100% for typical carcinoids and for adenocarcinomas manifesting as subsolid NCNs; 85% (95% CI 81-89%) for adenocarcinoma, 74% (95% CI 63-85%) for squamous cell, 48% (95% CI 34-62%) for small cell. The rank ordering by lead time was the same as the rank ordering by survival rates. The significant differences in the frequency of NCNs and frequency and aggressiveness of diagnosed cancers in baseline and annual repeat need to be recognised for an optimal regimen of screening. (orig.)

  3. 200-UP-2 Operable Unit technical baseline report

    International Nuclear Information System (INIS)

    Deford, D.H.

    1991-02-01

    This report is prepared in support of the development of a Remedial Investigation/Feasibility Study (RI/FS) Work Plan for the 200-UP-2 Operable Unit by EBASCO Environmental, Incorporated. It provides a technical baseline of the 200-UP-2 Operable Unit and results from an environmental investigation undertaken by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (Westinghouse Hanford). The 200-UP-2 Operable Unit Technical Baseline Report is based on review and evaluation of numerous Hanford Site current and historical reports, Hanford Site drawings and photographs and is supplemented with Hanford Site inspections and employee interviews. No field investigations or sampling were conducted. Each waste site in the 200-UP-2 Operable Unit is described separately. Close relationships between waste units, such as overflow from one to another, are also discussed. The 200-UP-2 Operable Unit consists of liquid-waste disposal sites in the vicinity of, and related to, U Plant operations in the 200 West Area of the Hanford Site. The ''U Plant'' refers to the 221-U Process Canyon Building, a chemical separations facility constructed during World War 2. It also includes the Uranium Oxide (UO 3 ) Plant, which was constructed at the same time and, like the 221-U Process Canyon Building, was later converted for other missions. Waste sites in the 200-UP-2 Operable Unit are associated with the U Plant Uranium Metal Recovery Program mission that occurred between 1952 and 1958 and the UO 3 Plant's ongoing uranium oxide mission and include one or more cribs, reverse wells, french drains, septic tanks and drain fields, trenches, catch tanks, settling tanks, diversion boxes, waste vaults, and the lines and encasements that connect them. 11 refs., 1 tab

  4. A novel type of very long baseline astronomical intensity interferometer

    Science.gov (United States)

    Borra, Ermanno F.

    2013-12-01

    This article presents a novel type of very long baseline astronomical interferometer that uses the fluctuations, as a function of time, of the intensity measured by a quadratic detector, which is a common type of astronomical detector. The theory on which the technique is based is validated by laboratory experiments. Its outstanding principal advantages comes from the fact that the angular structure of an astronomical object is simply determined from the visibility of the minima of the spectrum of the intensity fluctuations measured by the detector, as a function of the frequency of the fluctuations, while keeping the spacing between mirrors constant. This would allow a simple setup capable of high angular resolutions because it could use an extremely large baseline. Another major interest is that it allows for a more efficient use of telescope time because observations at a single baseline are sufficient, while amplitude and intensity interferometers need several observations at different baselines. The fact that one does not have to move the telescopes would also allow detecting faster time variations because having to move the telescopes sets a lower limit to the time variations that can be detected. The technique uses wave interaction effects and thus has some characteristics in common with intensity interferometry. A disadvantage of the technique, like in intensity interferometry, is that it needs strong sources if observing at high frequencies (e.g. the visible). This is a minor disadvantage in the radio region. At high frequencies, this disadvantage is mitigated by the fact that, like in intensity interferometry, the requirements of the optical quality of the mirrors used are far less severe than in amplitude interferometry so that poor quality large reflectors (e.g. Cherenkov telescopes) can be used in the optical region.

  5. Nerve Root Compression Increases Spinal Astrocytic Vimentin in Parallel With Sustained Pain and Endothelial Vimentin in Association With Spinal Vascular Reestablishment.

    Science.gov (United States)

    Smith, Jenell R; Lee, Jasmine; Winkelstein, Beth A

    2017-10-01

    Temporal immunohistochemistry analysis of spinal cord tissue from a rat model of cervical radiculopathy. The goal was to measure spinal endothelial and astrocytic vimentin expression after a painful nerve root compression to define spinal cellular expression of vimentin in the context of pain. The intermediate filament, vimentin, is expressed in a variety of cell types in the spinal cord and is modulated in response to neural pathologies. Early after nerve root compression spinal astrocytes become activated and blood-spinal cord barrier (BSCB) breakdown occurs in parallel with development of pain-related behaviors; these spinal responses remain activated as does the presence of pain. In addition to vimentin, glial fibrillary acidic protein (GFAP) expression is a hallmark of astrocyte activation. In contrast, vascular endothelial cells down-regulate vimentin expression in parallel with vascular breakdown. It is not known whether spinal astrocytes and endothelial cells modulate their expression of vimentin in response to a painful neural injury. Mechanical hyperalgesia was measured and spinal cord tissue was harvested at days 1 and 7 after a unilateral nerve root compression in rats. Vimentin was coimmunolabeled with GFAP to label astrocytes and von Willebrand factor (VWF) for endothelial cells in the spinal cord on the side of injury. Spinal astrocytic vimentin increases by day 7 after nerve root compression, corresponding to when mechanical hyperalgesia is maintained. Spinal endothelial vimentin increases as early as day 1 after a painful compression and is even more robust at day 7. The delayed elevation in spinal astrocytic vimentin corresponding to sustained mechanical hyperalgesia supports its having a relationship with pain maintenance. Further, since BSCB integrity has been shown to be reestablished by day 7 after a painful compression, endothelial expressed vimentin may help to fortify spinal vasculature contributing to BSCB stability. N/A.

  6. 75 FR 63452 - ONEOK Gas Storage, L.L.C.; Notice of Baseline Filing

    Science.gov (United States)

    2010-10-15

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR11-67-001] ONEOK Gas Storage, L.L.C.; Notice of Baseline Filing October 7, 2010. Take notice that on October 1, 2010, ONEOK Gas Storage, L.L.C. submitted a revised baseline filing of its Statement of Operating Conditions for services...

  7. Carbon and environmental footprinting of global biofuel production

    OpenAIRE

    Hammond, Geoff P.; Seth, S.M.

    2013-01-01

    The carbon and environmental footprints associated with the global production of biofuels have been computed from a baseline of 2007-2009 out until 2019. Estimates of future global biofuel production were adopted from OECD-FAO and related projections. In order to determine the footprints associated with these (essentially 'first generation') biofuel resources, the overall environmental footprint was disaggregated into bioproductive land, built land, carbon, embodied energy, materials and wast...

  8. Association of Electronic Cigarette Use With Initiation of Combustible Tobacco Product Smoking in Early Adolescence.

    Science.gov (United States)

    Leventhal, Adam M; Strong, David R; Kirkpatrick, Matthew G; Unger, Jennifer B; Sussman, Steve; Riggs, Nathaniel R; Stone, Matthew D; Khoddam, Rubin; Samet, Jonathan M; Audrain-McGovern, Janet

    2015-08-18

    Exposure to nicotine in electronic cigarettes (e-cigarettes) is becoming increasingly common among adolescents who report never having smoked combustible tobacco. To evaluate whether e-cigarette use among 14-year-old adolescents who have never tried combustible tobacco is associated with risk of initiating use of 3 combustible tobacco products (ie, cigarettes, cigars, and hookah). Longitudinal repeated assessment of a school-based cohort at baseline (fall 2013, 9th grade, mean age = 14.1 years) and at a 6-month follow-up (spring 2014, 9th grade) and a 12-month follow-up (fall 2014, 10th grade). Ten public high schools in Los Angeles, California, were recruited through convenience sampling. Participants were students who reported never using combustible tobacco at baseline and completed follow-up assessments at 6 or 12 months (N = 2530). At each time point, students completed self-report surveys during in-classroom data collections. Student self-report of whether he or she ever used e-cigarettes (yes or no) at baseline. Six- and 12-month follow-up reports on use of any of the following tobacco products within the prior 6 months: (1) any combustible tobacco product (yes or no); (2) combustible cigarettes (yes or no), (3) cigars (yes or no); (4) hookah (yes or no); and (5) number of combustible tobacco products (range: 0-3). Past 6-month use of any combustible tobacco product was more frequent in baseline e-cigarette ever users (n = 222) than never users (n = 2308) at the 6-month follow-up (30.7% vs 8.1%, respectively; difference between groups in prevalence rates, 22.7% [95% CI, 16.4%-28.9%]) and at the 12-month follow-up (25.2% vs 9.3%, respectively; difference between groups, 15.9% [95% CI, 10.0%-21.8%]). Baseline e-cigarette use was associated with greater likelihood of use of any combustible tobacco product averaged across the 2 follow-up periods in the unadjusted analyses (odds ratio [OR], 4.27 [95% CI, 3.19-5.71]) and in the analyses adjusted

  9. Sport and team differences on baseline measures of sport-related concussion.

    Science.gov (United States)

    Zimmer, Adam; Piecora, Kyle; Schuster, Danielle; Webbe, Frank

    2013-01-01

    With the advent of the National Collegiate Athletic Association's (NCAA's) mandating the presence and practice of concussion-management plans in collegiate athletic programs, institutions will consider potential approaches for concussion management, including both baseline and normative comparison approaches. To examine sport and team differences in baseline performance on a computer-based neurocognitive measure and 2 standard sideline measures of cognition and balance and to determine the potential effect of premorbid factors sex and height on baseline performance. Cross-sectional study. University laboratory. A total of 437 NCAA Division II student-athletes (males = 273, females = 164; age = 19.61 ± 1.64 years, height = 69.89 ± 4.04 inches [177.52 ± 10.26 cm]) were recruited during mandatory preseason testing conducted in a concussion-management program. The computerized Concussion Resolution Index (CRI), the Standardized Assessment of Concussion (Form A; SAC), and the Balance Error Scoring System (BESS). Players on the men's basketball team tended to perform worse on the baseline measures, whereas soccer players tended to perform better. We found a difference in total BESS scores between these sports (P = .002). We saw a difference between sports on the hard-surface portion of the BESS (F6,347 = 3.33, P = .003, ηp(2) = 0.05). No sport, team, or sex differences were found with SAC scores (P > .05). We noted differences between sports and teams in the CRI indices, with basketball, particularly the men's team, performing worse than soccer (P sport differences, height was a covariate for the team (F1,385 = 5.109, P = .02, ηp(2) = 0.013) and sport (F1,326 = 11.212, P = .001, ηp(2) = 0.033) analyses, but the interaction of sex and sport on CRI indices was not significant in any test (P > .05). Given that differences in neurocognitive functioning and performance among sports and teams exist, the comparison of posttraumatic and baseline assessment may lead to more

  10. SRP Baseline Hydrogeologic Investigation, Phase 3

    Energy Technology Data Exchange (ETDEWEB)

    Bledsoe, H.W.

    1988-08-01

    The SRP Baseline Hydrogeologic Investigation was implemented for the purpose of updating and improving the knowledge and understanding of the hydrogeologic systems underlying the SRP site. Phase III, which is discussed in this report, includes the drilling of 7 deep coreholes (sites P-24 through P-30) and the installation of 53 observation wells ranging in depth from approximately 50 ft to more than 970 ft below the ground surface. In addition to the collection of geologic cores for lithologic and stratigraphic study, samples were also collected for the determination of physical characteristics of the sediments and for the identification of microorganisms.

  11. Baseline-dependent averaging in radio interferometry

    Science.gov (United States)

    Wijnholds, S. J.; Willis, A. G.; Salvini, S.

    2018-05-01

    This paper presents a detailed analysis of the applicability and benefits of baseline-dependent averaging (BDA) in modern radio interferometers and in particular the Square Kilometre Array. We demonstrate that BDA does not affect the information content of the data other than a well-defined decorrelation loss for which closed form expressions are readily available. We verify these theoretical findings using simulations. We therefore conclude that BDA can be used reliably in modern radio interferometry allowing a reduction of visibility data volume (and hence processing costs for handling visibility data) by more than 80 per cent.

  12. Rationing in the presence of baselines

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Moreno-Ternero, Juan D.; Østerdal, Lars Peter

    2013-01-01

    We analyze a general model of rationing in which agents have baselines, in addition to claims against the (insufficient) endowment of the good to be allocated. Many real-life problems fit this general model (e.g., bankruptcy with prioritized claims, resource allocation in the public health care...... sector, water distribution in drought periods). We introduce (and characterize) a natural class of allocation methods for this model. Any method within the class is associated with a rule in the standard rationing model, and we show that if the latter obeys some focal properties, the former obeys them...

  13. Association of baseline bleeding pattern on amenorrhea with levonorgestrel intrauterine system use.

    Science.gov (United States)

    Mejia, Manuela; McNicholas, Colleen; Madden, Tessa; Peipert, Jeffrey F

    2016-11-01

    This study aims to evaluate the effect of baseline bleeding patterns on rates of amenorrhea reported at 12 months in levonorgestrel (LNG) 52 mg intrauterine system (IUS) users. We also assessed the effect of baseline bleeding patterns at 3 and 6 months postinsertion. In this secondary analysis of the Contraceptive CHOICE Project, we included participants who had an LNG-IUS inserted within 1 month of enrollment and continued use for 12 months. Using 12-month telephone survey data, we defined amenorrhea at 12 months of use as no bleeding or spotting during the previous 6 months. We used chi-square and multivariable logistic regression to assess the association of baseline bleeding pattern with amenorrhea while controlling for confounding variables. Of 1802 continuous 12-month LNG-IUS users, amenorrhea was reported by 4.9%, 14.8% and 15.4% of participants at 3, 6 and 12 months, receptively. Participants with light baseline bleeding or short duration of flow reported higher rates of amenorrhea at 3 and 6 months postinsertion (pamenorrhea at 3 and 6 months (pamenorrhea at 12 months than those who reported moderate bleeding (OR adj , 0.36; 95% CI, 0.16-0.69). Women with heavier menstrual bleeding are less likely than women with moderate flow to report amenorrhea following 12 months of LNG-IUS use. Baseline heavy menstrual flow reduces the likelihood of amenorrhea with LNG-IUS use, information that could impact contraceptive counseling. Anticipatory counseling can improve method satisfaction and continuation, an important strategy to continue to reduce unintended pregnancy and abortion rates. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Baseline Radioactivity Measurements In The Vicinity Of A Gold ...

    African Journals Online (AJOL)

    Western Region, Ghana) to obtain baseline radioactivity data prior to the installation of Cs-137 nuclear density gauges for quality control measure-ment of the density of slurry in the pipelines at the plant. A survey meter, gamma spectrometry and ...

  15. Meta-Analysis of the Relation of Baseline Right Ventricular Function to Response to Cardiac Resynchronization Therapy.

    Science.gov (United States)

    Sharma, Abhishek; Bax, Jerome J; Vallakati, Ajay; Goel, Sunny; Lavie, Carl J; Kassotis, John; Mukherjee, Debabrata; Einstein, Andrew; Warrier, Nikhil; Lazar, Jason M

    2016-04-15

    Right ventricular (RV) dysfunction has been associated with adverse clinical outcomes in patients with heart failure (HF). Cardiac resynchronization therapy (CRT) improves left ventricular (LV) size and function in patients with markedly abnormal electrocardiogram QRS duration. However, relation of baseline RV function with response to CRT has not been well described. In this study, we aim to investigate the relation of baseline RV function with response to CRT as assessed by change in LV ejection fraction (EF). A systematic search of studies published from 1966 to May 31, 2015 was conducted using PubMed, CINAHL, Cochrane CENTRAL, and the Web of Science databases. Studies were included if they have reported (1) parameters of baseline RV function (tricuspid annular plane systolic excursion [TAPSE] or RVEF or RV basal strain or RV fractional area change [FAC]) and (2) LVEF before and after CRT. Random-effects metaregression was used to evaluate the effect of baseline RV function parameters and change in LVEF. Sixteen studies (n = 1,764) were selected for final analysis. Random-effects metaregression analysis showed no significant association between the magnitude of the difference in EF before and after CRT with baseline TAPSE (β = 0.005, p = 0.989); baseline RVEF (β = 0.270, p = 0.493); baseline RVFAC (β = -0.367, p = 0.06); baseline basal strain (β = -0.342, p = 0.462) after a mean follow-up period of 10.5 months. In conclusion, baseline RV function as assessed by TAPSE, FAC, basal strain, or RVEF does not determine response to CRT as assessed by change in LVEF. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Evaluation of a dry process for conversion of U-AVLIS product to UF6. Milestone U361

    International Nuclear Information System (INIS)

    1992-05-01

    A technical and engineering evaluation has been completed for a dry UF 6 production system to convert the product of an initial two-line U-AVLIS plant. The objective of the study has been to develop a better understanding of process design requirements, capital and operating costs, and demonstration requirements for this alternate process. This report summarizes the results of the study and presents various comparisons between the baseline and alternate processes, building on the information contained in UF 6 Product Alternatives Review Committee -- Final Report. It also provides additional information on flowsheet variations for the dry route which may warrant further consideration. The information developed by this study and conceptual design information for the baseline process will be combined with information to be developed by the U-AVLIS program and by industrial participants over the next twelve months to permit a further comparison of the baseline and alternate processes in terms of cost, risk, and compatibility with U-AVLIS deployment schedules and strategies. This comparative information will be used to make a final process flowsheet selection for the initial U-AVLIS plant by March 1993. The process studied is the alternate UF 6 production flowsheet. Process steps are (1) electron-beam distillation to reduce enriched product iron content from about 10 wt % or less, (2) hydrofluorination of the metal to UF 4 , (3) fluorination of UF 4 to UF 6 , (4) cold trap collection of the UF 6 product, (5) UF 6 purification by distillation, and (6) final blending and packaging of the purified UF 6 in cylinders. A preliminary system design has been prepared for the dry UF 6 production process based on currently available technical information. For some process steps, such information is quite limited. Comparisons have been made between this alternate process and the baseline plant process for UF 6 production

  17. Effect of Physical Therapy Students' Clinical Experiences on Clinician Productivity.

    Science.gov (United States)

    Pivko, Susan E; Abbruzzese, Laurel D; Duttaroy, Pragati; Hansen, Ruth L; Ryans, Kathryn

    2016-01-01

    Physical therapy clinical education experiences (CEEs) are difficult to secure, particularly first-level CEEs. Our purpose was to determine 1) what impact student full-time CEEs have on PT clinician productivity and 2) whether there is a productivity difference between first vs final CEEs. Productivity logs, including possible factors impacting productivity, were distributed to clinician-student pairings on first and final CEEs. Two-week baseline data (without a student) were compared to weeks 1 and 6 (with a student) for 31 logs using a 2x4 repeated-measures ANOVA. In a subset of 17 logs for CEEs 8 weeks or longer, a 2x5 repeated-measures ANOVA was performed. There was a significant increase in the number of patients seen and CPT units billed by both levels of CEEs comparing weeks 1 and 6. In the subset of CEEs, 8 weeks or longer, there was a significant increase in the number of patients treated per hour at week 6 and a trend toward a change at week 8 when compared to baseline week A. The factors selected as impacting productivity were census (59%) and staffing (32%). Physical therapy clinician-student pairings showed an overall increase in productivity during both full-time first and final level CEEs.

  18. Baseline and Target Values for PV Forecasts: Toward Improved Solar Power Forecasting: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jie; Hodge, Bri-Mathias; Lu, Siyuan; Hamann, Hendrik F.; Lehman, Brad; Simmons, Joseph; Campos, Edwin; Banunarayanan, Venkat

    2015-08-05

    Accurate solar power forecasting allows utilities to get the most out of the solar resources on their systems. To truly measure the improvements that any new solar forecasting methods can provide, it is important to first develop (or determine) baseline and target solar forecasting at different spatial and temporal scales. This paper aims to develop baseline and target values for solar forecasting metrics. These were informed by close collaboration with utility and independent system operator partners. The baseline values are established based on state-of-the-art numerical weather prediction models and persistence models. The target values are determined based on the reduction in the amount of reserves that must be held to accommodate the uncertainty of solar power output. forecasting metrics. These were informed by close collaboration with utility and independent system operator partners. The baseline values are established based on state-of-the-art numerical weather prediction models and persistence models. The target values are determined based on the reduction in the amount of reserves that must be held to accommodate the uncertainty of solar power output.

  19. Low baseline levels of NK cells may predict a positive response to ipilimumab in melanoma therapy.

    Science.gov (United States)

    Tietze, Julia K; Angelova, Daniela; Heppt, Markus V; Ruzicka, Thomas; Berking, Carola

    2017-07-01

    The introduction of immune checkpoint blockade (ICB) has been a breakthrough in the therapy of metastatic melanoma. The influence of ICB on T-cell populations has been studied extensively, but little is known about the effect on NK cells. In this study, we analysed the relative and absolute amounts of NK cells and of the subpopulations of CD56 dim and CD56 bright NK cells among the peripheral blood mononuclear cells (PBMCs) of 32 patients with metastatic melanoma before and under treatment with ipilimumab or pembrolizumab by flow cytometry. In 15 (47%) patients, an abnormal low amount of NK cells was found at baseline. Analysis of the subpopulations showed also low or normal baseline levels for CD56 dim NK cells, whereas the baseline levels of CD56 bright NK cells were either normal or abnormally high. The relative and absolute amounts of NK cells and of CD56 dim and CD56 bright NK cell subpopulations in patients with a normal baseline did not change under treatment. However, patients with a low baseline of NK cells and CD56 dim NK cells showed a significant increase in these immune cell subsets, but the amounts remained to be lower than the normal baseline. The amount of CD56 bright NK cells was unaffected by treatment. The baseline levels of NK cells were correlated with the number of metastatic organs. Their proportion increased, whereas the expression of NKG2D decreased significantly when more than one organ was affected by metastases. Low baseline levels of NK cells and CD56 dim NK cells as well as normal baseline levels of CD56 bright NK cells correlated significantly with a positive response to ipilimumab but not to pembrolizumab. Survival curves of patients with low amounts of CD56 dim NK cells treated with ipilimumab showed a trend to longer survival. Normal baseline levels of CD56 bright NK cells were significantly correlated with longer survival as compared to patients with high baseline levels. In conclusion, analysis of the amounts of total NK cells

  20. Imputation of Baseline LDL Cholesterol Concentration in Patients with Familial Hypercholesterolemia on Statins or Ezetimibe.

    Science.gov (United States)

    Ruel, Isabelle; Aljenedil, Sumayah; Sadri, Iman; de Varennes, Émilie; Hegele, Robert A; Couture, Patrick; Bergeron, Jean; Wanneh, Eric; Baass, Alexis; Dufour, Robert; Gaudet, Daniel; Brisson, Diane; Brunham, Liam R; Francis, Gordon A; Cermakova, Lubomira; Brophy, James M; Ryomoto, Arnold; Mancini, G B John; Genest, Jacques

    2018-02-01

    Familial hypercholesterolemia (FH) is the most frequent genetic disorder seen clinically and is characterized by increased LDL cholesterol (LDL-C) (>95th percentile), family history of increased LDL-C, premature atherosclerotic cardiovascular disease (ASCVD) in the patient or in first-degree relatives, presence of tendinous xanthomas or premature corneal arcus, or presence of a pathogenic mutation in the LDLR , PCSK9 , or APOB genes. A diagnosis of FH has important clinical implications with respect to lifelong risk of ASCVD and requirement for intensive pharmacological therapy. The concentration of baseline LDL-C (untreated) is essential for the diagnosis of FH but is often not available because the individual is already on statin therapy. To validate a new algorithm to impute baseline LDL-C, we examined 1297 patients. The baseline LDL-C was compared with the imputed baseline obtained within 18 months of the initiation of therapy. We compared the percent reduction in LDL-C on treatment from baseline with the published percent reductions. After eliminating individuals with missing data, nonstandard doses of statins, or medications other than statins or ezetimibe, we provide data on 951 patients. The mean ± SE baseline LDL-C was 243.0 (2.2) mg/dL [6.28 (0.06) mmol/L], and the mean ± SE imputed baseline LDL-C was 244.2 (2.6) mg/dL [6.31 (0.07) mmol/L] ( P = 0.48). There was no difference in response according to the patient's sex or in percent reduction between observed and expected for individual doses or types of statin or ezetimibe. We provide a validated estimation of baseline LDL-C for patients with FH that may help clinicians in making a diagnosis. © 2017 American Association for Clinical Chemistry.

  1. Baseline radiological monitoring at proposed uranium prospecting site at Rohil Sikar, Rajasthan

    International Nuclear Information System (INIS)

    Kumar, Rajesh; Jha, V.N.; Sahoo, N.K.; Jha, S.K.; Tripathi, R.M.

    2018-01-01

    Once economically viable grades of uranium deposits are proposed for mining and processing by the industry radiological baseline studies are required for future comparison during operational phases. The information collected during such studies serve as connecting feature between regulatory compliance and technical information. Present paper summarizes the results of baseline monitoring of atmospheric 222 Rn and gamma level in the area at prospecting mining, milling and waste disposal sites of Rohil Rajasthan

  2. Development of an approach to correcting MicroPEM baseline drift.

    Science.gov (United States)

    Zhang, Ting; Chillrud, Steven N; Pitiranggon, Masha; Ross, James; Ji, Junfeng; Yan, Beizhan

    2018-07-01

    Fine particulate matter (PM 2.5 ) is associated with various adverse health outcomes. The MicroPEM (RTI, NC), a miniaturized real-time portable particulate sensor with an integrated filter for collecting particles, has been widely used for personal PM 2.5 exposure assessment. Five-day deployments were targeted on a total of 142 deployments (personal or residential) to obtain real-time PM 2.5 levels from children living in New York City and Baltimore. Among these 142 deployments, 79 applied high-efficiency particulate air (HEPA) filters in the field at the beginning and end of each deployment to adjust the zero level of the nephelometer. However, unacceptable baseline drift was observed in a large fraction (> 40%) of acquisitions in this study even after HEPA correction. This drift issue has been observed in several other studies as well. The purpose of the present study is to develop an algorithm to correct the baseline drift in MicroPEM based on central site ambient data during inactive time periods. A running baseline & gravimetric correction (RBGC) method was developed based on the comparison of MicroPEM readings during inactive periods to ambient PM 2.5 levels provided by fixed monitoring sites and the gravimetric weight of PM 2.5 collected on the MicroPEM filters. The results after RBGC correction were compared with those using HEPA approach and gravimetric correction alone. Seven pairs of duplicate acquisitions were used to validate the RBGC method. The percentages of acquisitions with baseline drift problems were 42%, 53% and 10% for raw, HEPA corrected, and RBGC corrected data, respectively. Pearson correlation analysis of duplicates showed an increase in the coefficient of determination from 0.75 for raw data to 0.97 after RBGC correction. In addition, the slope of the regression line increased from 0.60 for raw data to 1.00 after RBGC correction. The RBGC approach corrected the baseline drift issue associated with MicroPEM data. The algorithm developed

  3. Super-NOvA a long-baseline neutrino experiment with two off-axis detectors

    CERN Document Server

    Requejo, O M; Pascoli, S; Requejo, Olga Mena; Palomares-Ruiz, Sergio; Pascoli, Silvia

    2005-01-01

    Establishing the neutrino mass hierarchy is one of the fundamental questions that will have to be addressed in the next future. Its determination could be obtained with long-baseline experiments but typically suffers from degeneracies with other neutrino parameters. We consider here the NOvA experiment configuration and propose to place a second off-axis detector, with a shorter baseline, such that, by exploiting matter effects, the type of neutrino mass hierarchy could be determined with only the neutrino run. We show that the determination of this parameter is free of degeneracies, provided the ratio L/E, where L the baseline and E is the neutrino energy, is the same for both detectors.

  4. The impact of sterile neutrinos on CP measurements at long baselines

    International Nuclear Information System (INIS)

    Gandhi, Raj; Kayser, Boris; Masud, Mehedi; Prakash, Suprabh

    2015-01-01

    With the Deep Underground Neutrino Experiment (DUNE) as an example, we show that the presence of even one sterile neutrino of mass ∼1 eV can significantly impact the measurements of CP violation in long baseline experiments. Using a probability level analysis and neutrino-antineutrino asymmetry calculations, we discuss the large magnitude of these effects, and show how they translate into significant event rate deviations at DUNE. Our results demonstrate that measurements which, when interpreted in the context of the standard three family paradigm, indicate CP conservation at long baselines, may, in fact hide large CP violation if there is a sterile state. Similarly, any data indicating the violation of CP cannot be properly interpreted within the standard paradigm unless the presence of sterile states of mass O(1 eV) can be conclusively ruled out. Our work underscores the need for a parallel and linked short baseline oscillation program and a highly capable near detector for DUNE, in order that its highly anticipated results on CP violation in the lepton sector may be correctly interpreted.

  5. Near Detectors based on gas TPCs for neutrino long baseline experiments

    CERN Document Server

    Blondel, A

    2017-01-01

    Time Projection Chambers have been used with success for the T2K ND280 near detector and are proposed for an upgrade of the T2K near detector. High pressure TPCs are also being considered for future long-baseline experiments like Hyper-Kamiokande and DUNE. A High Pressure TPC would be a very sensitive detector for the detailed study of neutrino-nucleus interactions, a limiting factor for extracting the ultimate precision in long baseline experiments. The requirements of TPCs for neutrino detectors are quite specific. We propose here the development of state-of-the-art near detectors based on gas TPC: atmospheric pressure TPCs for T2K-II and a high-pressure TPC for neutrino experiments. The project proposed here benefits from a strong involvement of the European (CERN) members of the T2K collaboration and beyond. It is a strongly synergetic precursor of other projects of near detectors using gas TPCs that are under discussion for the long baseline neutrino projects worldwide. It will help maintain and develop...

  6. Induction of bacteriocin production by coculture is widespread among plantaricin-producing Lactobacillus plantarum strains with different regulatory operons.

    Science.gov (United States)

    Maldonado-Barragán, Antonio; Caballero-Guerrero, Belén; Lucena-Padrós, Helena; Ruiz-Barba, José Luis

    2013-02-01

    We describe the bacteriocin-production phenotype in a group of eight singular bacteriocinogenic Lactobacillus plantarum strains with three distinct genotypes regarding the plantaricin locus. Genotyping of these strains revealed the existence of two different plantaricin-production regulatory operons, plNC8-plNC8HK-plnD or plnABCD, involving three-component systems controlled each of them by a specific autoinducer peptide (AIP), i.e. PLNC8IF or PlnA. While all of the strains produced antimicrobial activity when growing on solid medium, most of them halted this production when cultured in broth, thus reflecting the functionality of regulatory mechanisms. Antimicrobial activity in broth cultures was re-established or enhanced when the specific AIP was added to the culture or by coculturing with specific bacterial strains. The latter trait appeared to be widespread in bacteriocinogenic L. plantarum strains independently of the regulatory system used to regulate bacteriocin production or the specific bacteriocins produced. The induction spectrum through coculture, i.e. the pattern of bacterial strains able to induce bacteriocin production, was characteristic of each individual L. plantarum strain. Also, the ability of some bacteria to induce bacteriocin production in L. plantarum by coculture appeared to be strain specific. The fact that induction of bacteriocin production by coculturing appeared to be a common feature in L. plantarum can be exploited accordingly to enhance the viability of this species in food and feed fermentations, as well as to contribute to probiotic functionality when colonising the gastrointestinal tract. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Relationship between visual field progression and baseline refraction in primary open-angle glaucoma.

    Science.gov (United States)

    Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Umeda, Yuzo; Shiraga, Fumio

    2016-01-01

    To analyze the relationship between visual field (VF) progression and baseline refraction in Japanese patients with primary open-angle glaucoma (POAG) including normal-tension glaucoma. In this retrospective study, the subjects were patients with POAG who had undergone VF tests at least ten times with a Humphrey Field Analyzer (Swedish interactive thresholding algorithm standard, Central 30-2 program). VF progression was defined as a significantly negative value of mean deviation (MD) slope at the final VF test. Multivariate logistic regression models were applied to detect an association between MD slope deterioration and baseline refraction. A total of 156 eyes of 156 patients were included in this analysis. Significant deterioration of MD slope was observed in 70 eyes of 70 patients (44.9%), whereas no significant deterioration was evident in 86 eyes of 86 patients (55.1%). The eyes with VF progression had significantly higher baseline refraction compared to those without apparent VF progression (-1.9±3.8 diopter [D] vs -3.5±3.4 D, P=0.0048) (mean ± standard deviation). When subject eyes were classified into four groups by the level of baseline refraction applying spherical equivalent (SE): no myopia (SE > -1D), mild myopia (-1D ≥ SE > -3D), moderate myopia (-3D ≥ SE > -6D), and severe myopia (-6D ≥ SE), the Cochran-Armitage trend analysis showed a decreasing trend in the proportion of MD slope deterioration with increasing severity of myopia (P=0.0002). The multivariate analysis revealed that baseline refraction (P=0.0108, odds ratio [OR]: 1.13, 95% confidence interval [CI]: 1.03-1.25) and intraocular pressure reduction rate (P=0.0150, OR: 0.97, 95% CI: 0.94-0.99) had a significant association with MD slope deterioration. In the current analysis of Japanese patients with POAG, baseline refraction was a factor significantly associated with MD slope deterioration as well as intraocular pressure reduction rate. When baseline refraction was classified into

  8. Heat production and body temperature during cooling and rewarming in overweight and lean men.

    Science.gov (United States)

    Claessens-van Ooijen, Anne M J; Westerterp, Klaas R; Wouters, Loek; Schoffelen, Paul F M; van Steenhoven, Anton A; van Marken Lichtenbelt, Wouter D

    2006-11-01

    To compare overweight and lean subjects with respect to thermogenesis and physiological insulation in response to mild cold and rewarming. Ten overweight men (mean BMI, 29.2 +/- 2.8 kg/m(2)) and 10 lean men (mean BMI, 21.1 +/- 2.0 kg/m(2)) were exposed to cold air for 1 hour, followed by 1 hour of rewarming. Body composition was determined by hydrodensitometry and deuterium dilution. Heat production and body temperatures were measured continuously by indirect calorimetry and thermistors, respectively. Muscle activity was recorded using electromyography. In both groups, heat production increased significantly during cooling (lean, p = 0.004; overweight, p = 0.006). The increase was larger in the lean group compared with the overweight group (p = 0.04). During rewarming, heat production returned to baseline in the overweight group and stayed higher compared with baseline in the lean group (p = 0.003). The difference in heat production between rewarming and baseline was larger in the lean (p = 0.01) than in the overweight subjects. Weighted body temperature of both groups decreased during cold exposure (lean, p = 0.002; overweight, p < 0.001) and did not return to baseline during rewarming. Overweight subjects showed a blunted mild cold-induced thermogenesis. The insulative cold response was not different among the groups. The energy-efficient response of the overweight subjects can have consequences for energy balance in the long term. The results support the concept of a dynamic heat regulation model instead of temperature regulation around a fixed set point.

  9. Overview of the Long-Baseline Neutrino Facility cryogenic system

    CERN Document Server

    Montanari, David; Bremer, Johan; Delaney, Michael; Aurelien, Diaz; Doubnik, Roza; Haaf, Kevin; Hentschel, Steve; Norris, Barry; Voirin, Erik

    2017-01-01

    The Deep Underground Neutrino Experiment (DUNE) collaboration is developing a multi-kiloton Long-Baseline neutrino experiment that will be located one mile underground at the Sanford Underground Research Facility (SURF) in Lead, SD. In the present design, detectors will be located inside four cryostats filled with a total of 68,400 ton of ultrapure liquid argon, at the level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The Long-Baseline Neutrino Facility (LBNF) is developing the conventional facilities and cryogenics infrastructure supporting this experiment. The cryogenics system is composed of several sub-systems: External/Infrastructure, Proximity, and Internal cryogenics. It will be engineered, manufactured, commissioned, and qualified by an international engineering team. This contribution highlights the main features of the LBNF cryogenic system. It presents its performance, functional requirements and modes of operations. It also details the status of the design, ...

  10. Decomposition for emission baseline setting in China's electricity sector

    International Nuclear Information System (INIS)

    Steenhof, Paul A.

    2007-01-01

    Decomposition analysis is used to generate carbon dioxide emission baselines in China's electricity sector to the year 2020. This is undertaken from the vantage point of the final consumer of electricity, and therefore considers factors influencing electricity demand, efficiency of generation, sources of energy used for generation purposes, and the effectiveness of transmission and distribution. It is found that since 1980, gains in efficiency of generation have been the most important factor affecting change in the emission intensity of electricity generated. Based upon known energy and economic policy, efficiency gains will continue to contribute to reductions in the emission intensity of electricity generated, however, fuel shifts to natural gas and increases in nuclear generation will further these trends into the future. The analysis confirms other sources in the literature that decomposition is an appropriate technique available for baseline construction, thereby suitable for the emerging carbon market and its related mechanisms

  11. The Female Athlete Body (FAB) study: Rationale, design, and baseline characteristics.

    Science.gov (United States)

    Stewart, Tiffany M; Pollard, Tarryn; Hildebrandt, Tom; Beyl, Robbie; Wesley, Nicole; Kilpela, Lisa Smith; Becker, Carolyn Black

    2017-09-01

    Eating Disorders (EDs) are serious psychiatric illnesses marked by psychiatric comorbidity, medical complications, and functional impairment. Research indicates that female athletes are often at greater risk for developing ED pathology versus non-athlete females. The Female Athlete Body (FAB) study is a three-site, randomized controlled trial (RCT) designed to assess the efficacy of a behavioral ED prevention program for female collegiate athletes when implemented by community providers. This paper describes the design, intervention, and participant baseline characteristics. Future papers will discuss outcomes. Female collegiate athletes (N=481) aged 17-21 were randomized by site, team, and sport type to either FAB or a waitlist control group. FAB consisted of three sessions (1.3h each) of a behavioral ED prevention program. Assessments were conducted at baseline (pre-intervention), post-intervention (3weeks), and six-, 12-, and 18-month follow-ups. This study achieved 96% (N=481) of target recruitment (N=500). Few group differences emerged at baseline. Total sample analyses revealed moderately low baseline instances of ED symptoms and clinical cases. Health risks associated with EDs necessitate interventions for female athletes. The FAB study is the largest existing RCT for female athletes aimed at both reduction of ED risk factors and ED prevention. The methods presented and population recruited for this study represent an ideal intervention for assessing the effects of FAB on both the aforementioned outcomes. We anticipate that findings of this study (reported in future papers) will make a significant contribution to the ED risk factor reduction and prevention literature. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Impact of baseline BMI and weight change in CCTG adjuvant breast cancer trials.

    Science.gov (United States)

    Yerushalmi, R; Dong, B; Chapman, J W; Goss, P E; Pollak, M N; Burnell, M J; Levine, M N; Bramwell, V H C; Pritchard, K I; Whelan, T J; Ingle, J N; Shepherd, L E; Parulekar, W R; Han, L; Ding, K; Gelmon, K A

    2017-07-01

    We hypothesized that increased baseline BMI and BMI change would negatively impact clinical outcomes with adjuvant breast cancer systemic therapy. Data from chemotherapy trials MA.5 and MA.21; endocrine therapy MA.12, MA.14 and MA.27; and trastuzumab HERA/MA.24 were analyzed. The primary objective was to examine the effect of BMI change on breast cancer-free interval (BCFI) landmarked at 5 years; secondary objectives included BMI changes at 1 and 3 years; BMI changes on disease-specific survival (DSS) and overall survival (OS); and effects of baseline BMI. Stratified analyses included trial therapy and composite trial stratification factors. In pre-/peri-/early post-menopausal chemotherapy trials (N = 2793), baseline BMI did not impact any endpoint and increased BMI from baseline did not significantly affect BCFI (P = 0.85) after 5 years although it was associated with worse BCFI (P = 0.03) and DSS (P = 0.07) after 1 year. BMI increase by 3 and 5 years was associated with better DSS (P = 0.01; 0.01) and OS (P = 0.003; 0.05). In pre-menopausal endocrine therapy trial MA.12 (N = 672), patients with higher baseline BMI had worse BCFI (P = 0.02) after 1 year, worse DSS (P = 0.05; 0.004) after 1 and 5 years and worse OS (P = 0.01) after 5 years. Increased BMI did not impact BCFI (P = 0.90) after 5 years, although it was associated with worse BCFI (P = 0.01) after 1 year. In post-menopausal endocrine therapy trials MA.14 and MA.27 (N = 8236), baseline BMI did not significantly impact outcome for any endpoint. BMI change did not impact BCFI or DSS after 1 or 3 years, although a mean increased BMI of 0.3 was associated with better OS (P = 0.02) after 1 year. With the administration of trastuzumab (N = 1395) baseline BMI and BMI change did not significantly impact outcomes. Higher baseline BMI and BMI increases negatively affected outcomes only in pre-/peri-/early post-menopausal trial patients. Otherwise, BMI

  13. Analysis of the baseline survey on the prevalence of Salmonella in holdings with breeding pigs in the EU, 2008

    DEFF Research Database (Denmark)

    Bole-Hribovšek, Vojislava; Chriél, Mariann; Davies, Robert

    Union was 54 and 88, respectively. Salmonella Derby and Salmonella Typhimurium predominated in both types of holdings. Breeding pigs may be an important source of dissemination of Salmonella throughout the pig-production chain. The results of this survey provide valuable information for setting......Salmonella is a major cause of food-borne illness in humans. Farm animals and foods of animal origin are important sources of human Salmonella infections. This European Union-wide Salmonella baseline survey was conducted in 2008 in holdings with breeding pigs. A total of 1,609 holdings housing...... and selling mainly breeding pigs (breeding holdings) and 3,508 holdings housing breeding pigs and selling mainly pigs for fattening or slaughter (production holdings) from 24 European Union Member States and two non-Member States, were randomly selected and included in the survey. In each selected breeding...

  14. An Improved Rank Correlation Effect Size Statistic for Single-Case Designs: Baseline Corrected Tau.

    Science.gov (United States)

    Tarlow, Kevin R

    2017-07-01

    Measuring treatment effects when an individual's pretreatment performance is improving poses a challenge for single-case experimental designs. It may be difficult to determine whether improvement is due to the treatment or due to the preexisting baseline trend. Tau- U is a popular single-case effect size statistic that purports to control for baseline trend. However, despite its strengths, Tau- U has substantial limitations: Its values are inflated and not bound between -1 and +1, it cannot be visually graphed, and its relatively weak method of trend control leads to unacceptable levels of Type I error wherein ineffective treatments appear effective. An improved effect size statistic based on rank correlation and robust regression, Baseline Corrected Tau, is proposed and field-tested with both published and simulated single-case time series. A web-based calculator for Baseline Corrected Tau is also introduced for use by single-case investigators.

  15. Structure of a traditional baseline data system

    Energy Technology Data Exchange (ETDEWEB)

    1976-12-01

    Research was conducted to determine whether appropriate data exist for the development of a comprehensive statistical baseline data system on the human environment in the Athabasca oil sands region of Alberta. The existing data sources pertinent to the target area were first reviewed and discussed. Criteria were selected to assist the evaluation of data, including type of data collected, source, degree of detail, geographic identification, accessibility, and time frame. These criteria allowed assessing whether the data would be amenable to geographically-coded, continuous monitoring systems. It was found that the Statistics Canada Census provided the most detail, the most complete coverage of the target area, the smallest statistical areas, the greatest consistency in data and data collection, and the most regular collection. The local agency collection efforts were generally oriented toward specific goals and the data intended primarily for intra-agency use. The smallest statistical units in these efforts may be too large to be of value to a common small-area system, and data collection agencies did not generally use coterminous boundaries. Recommendations were made to give primary consideration to Statistics Canada data in the initial development of the baseline data system. Further development of such a system depends on the adoption by local agencies of a common small-area system for data collection. 38 refs., 6 figs.

  16. Analysis of baseline gene expression levels from ...

    Science.gov (United States)

    The use of gene expression profiling to predict chemical mode of action would be enhanced by better characterization of variance due to individual, environmental, and technical factors. Meta-analysis of microarray data from untreated or vehicle-treated animals within the control arm of toxicogenomics studies has yielded useful information on baseline fluctuations in gene expression. A dataset of control animal microarray expression data was assembled by a working group of the Health and Environmental Sciences Institute's Technical Committee on the Application of Genomics in Mechanism Based Risk Assessment in order to provide a public resource for assessments of variability in baseline gene expression. Data from over 500 Affymetrix microarrays from control rat liver and kidney were collected from 16 different institutions. Thirty-five biological and technical factors were obtained for each animal, describing a wide range of study characteristics, and a subset were evaluated in detail for their contribution to total variability using multivariate statistical and graphical techniques. The study factors that emerged as key sources of variability included gender, organ section, strain, and fasting state. These and other study factors were identified as key descriptors that should be included in the minimal information about a toxicogenomics study needed for interpretation of results by an independent source. Genes that are the most and least variable, gender-selectiv

  17. High Rates of Baseline Drug Resistance and Virologic Failure Among ART-naive HIV-infected Children in Mali.

    Science.gov (United States)

    Crowell, Claudia S; Maiga, Almoustapha I; Sylla, Mariam; Taiwo, Babafemi; Kone, Niaboula; Oron, Assaf P; Murphy, Robert L; Marcelin, Anne-Geneviève; Traore, Ban; Fofana, Djeneba B; Peytavin, Gilles; Chadwick, Ellen G

    2017-11-01

    Limited data exist on drug resistance and antiretroviral treatment (ART) outcomes in HIV-1-infected children in West Africa. We determined the prevalence of baseline resistance and correlates of virologic failure (VF) in a cohort of ART-naive HIV-1-infected children baseline (before ART) and at 6 months. Resistance was defined according to the Stanford HIV Genotypic Resistance database. VF was defined as viral load ≥1000 copies/mL after 6 months of ART. Logistic regression was used to evaluate factors associated with VF or death >1 month after enrollment. Post hoc, antiretroviral concentrations were assayed on baseline samples of participants with baseline resistance. One-hundred twenty children with a median age 2.6 years (interquartile range: 1.6-5.0) were included. Eighty-eight percent reported no prevention of mother-to-child transmission exposure. At baseline, 27 (23%), 4 (3%) and none had non-nucleoside reverse transcriptase inhibitor (NNRTI), nucleoside reverse transcriptase inhibitor or protease inhibitor resistance, respectively. Thirty-nine (33%) developed VF and 4 died >1 month post-ART initiation. In multivariable analyses, poor adherence [odds ratio (OR): 6.1, P = 0.001], baseline NNRTI resistance among children receiving NNRTI-based ART (OR: 22.9, P baseline NNRTI resistance (OR: 5.8, P = 0.018) were significantly associated with VF/death. Ten (38%) with baseline resistance had detectable levels of nevirapine or efavirenz at baseline; 7 were currently breastfeeding, but only 2 reported maternal antiretroviral use. Baseline NNRTI resistance was common in children without reported NNRTI exposure and was associated with increased risk of treatment failure. Detectable NNRTI concentrations were present despite few reports of maternal/infant antiretroviral use.

  18. Project management with dynamic scheduling baseline scheduling, risk analysis and project control

    CERN Document Server

    Vanhoucke, Mario

    2013-01-01

    The topic of this book is known as dynamic scheduling, and is used to refer to three dimensions of project management and scheduling: the construction of a baseline schedule and the analysis of a project schedule's risk as preparation of the project control phase during project progress. This dynamic scheduling point of view implicitly assumes that the usability of a project's baseline schedule is rather limited and only acts as a point of reference in the project life cycle.

  19. CryoSat Ice Processor: Known Processor Anomalies and Potential Future Product Evolutions

    Science.gov (United States)

    Mannan, R.; Webb, E.; Hall, A.; Bouffard, J.; Femenias, P.; Parrinello, T.; Bouffard, J.; Brockley, D.; Baker, S.; Scagliola, M.; Urien, S.

    2016-08-01

    Launched in 2010, CryoSat was designed to measure changes in polar sea ice thickness and ice sheet elevation. To reach this goal the CryoSat data products have to meet the highest performance standards and are subjected to a continual cycle of improvement achieved through upgrades to the Instrument Processing Facilities (IPFs). Following the switch to the Baseline-C Ice IPFs there are already planned evolutions for the next processing Baseline, based on recommendations from the Scientific Community, Expert Support Laboratory (ESL), Quality Control (QC) Centres and Validation campaigns. Some of the proposed evolutions, to be discussed with the scientific community, include the activation of freeboard computation in SARin mode, the potential operation of SARin mode over flat-to-slope transitory land ice areas, further tuning of the land ice retracker, the switch to NetCDF format and the resolution of anomalies arising in Baseline-C. This paper describes some of the anomalies known to affect Baseline-C in addition to potential evolutions that are planned and foreseen for Baseline-D.

  20. Baseline simple and complex reaction times in female compared to male boxers.

    Science.gov (United States)

    Bianco, M; Ferri, M; Fabiano, C; Giorgiano, F; Tavella, S; Manili, U; Faina, M; Palmieri, V; Zeppilli, P

    2011-06-01

    The aim of the study was to compare baseline cognitive performance of female in respect to male amateur boxers. Study population included 28 female amateur boxers. Fifty-six male boxers, matched for age, employment and competitive level to female athletes, formed the control group. All boxers had no history of head concussions (except boxing). Each boxer was requested to: 1) fulfill a questionnaire collecting demographic data, level of education, occupational status, boxing record and number of head concussions during boxing; 2) undergo a baseline computerized neuropsychological (NP) test (CogSport) measuring simple and complex reaction times (RT). Female were lighter than male boxers (56±7 vs. 73.1±9.8 kg, Pknock-outs, etc.) correlated with NP scores. Female and male Olympic-style boxers have no (or minimal) differences in baseline cognitive performance. Further research with larger series of female boxers is required to confirm these findings.

  1. Baseline Plasma C-Reactive Protein Concentrations and Motor Prognosis in Parkinson Disease.

    Directory of Open Access Journals (Sweden)

    Atsushi Umemura

    Full Text Available C-reactive protein (CRP, a blood inflammatory biomarker, is associated with the development of Alzheimer disease. In animal models of Parkinson disease (PD, systemic inflammatory stimuli can promote neuroinflammation and accelerate dopaminergic neurodegeneration. However, the association between long-term systemic inflammations and neurodegeneration has not been assessed in PD patients.To investigate the longitudinal effects of baseline CRP concentrations on motor prognosis in PD.Retrospective analysis of 375 patients (mean age, 69.3 years; mean PD duration, 6.6 years. Plasma concentrations of high-sensitivity CRP were measured in the absence of infections, and the Unified Parkinson's Disease Rating Scale Part III (UPDRS-III scores were measured at five follow-up intervals (Days 1-90, 91-270, 271-450, 451-630, and 631-900.Change of UPDRS-III scores from baseline to each of the five follow-up periods.Change in UPDRS-III scores was significantly greater in PD patients with CRP concentrations ≥0.7 mg/L than in those with CRP concentrations <0.7 mg/L, as determined by a generalized estimation equation model (P = 0.021 for the entire follow-up period and by a generalized regression model (P = 0.030 for the last follow-up interval (Days 631-900. The regression coefficients of baseline CRP for the two periods were 1.41 (95% confidence interval [CI] 0.21-2.61 and 2.62 (95% CI 0.25-4.98, respectively, after adjusting for sex, age, baseline UPDRS-III score, dementia, and incremental L-dopa equivalent dose.Baseline plasma CRP levels were associated with motor deterioration and predicted motor prognosis in patients with PD. These associations were independent of sex, age, PD severity, dementia, and anti-Parkinsonian agents, suggesting that subclinical systemic inflammations could accelerate neurodegeneration in PD.

  2. Mercury exposure may suppress baseline corticosterone levels in juvenile birds.

    Science.gov (United States)

    Herring, Garth; Ackerman, Joshua T; Herzog, Mark P

    2012-06-05

    Mercury exposure has been associated with a wide variety of negative reproductive responses in birds, however few studies have examined the potential for chick impairment via the hypothalamic-pituitary-adrenal (HPA) axis. The HPA axis regulates corticosterone levels during periods of stress. We examined the relationship between baseline fecal corticosterone metabolite concentrations and mercury concentrations in down feathers of recently hatched (feathers (decreasing by 45% across the range of observed mercury concentrations) while accounting for stronger positive correlations between corticosterone concentrations and colony nest abundance and date. These results indicate that chronic mercury exposure may suppress baseline corticosterone concentrations in tern chicks and suggests that a juvenile bird's ability to respond to stress may be reduced via the downregulation of the HPA axis.

  3. BASELINE DESIGN/ECONOMICS FOR ADVANCED FISCHER-TROPSCH TECHNOLOGY; FINAL

    International Nuclear Information System (INIS)

    None

    1998-01-01

    Bechtel, along with Amoco as the main subcontractor, developed a Baseline design, two alternative designs, and computer process simulation models for indirect coal liquefaction based on advanced Fischer-Tropsch (F-T) technology for the U. S. Department of Energy's (DOE's) Federal Energy Technology Center (FETC)

  4. The Dutch CAFE baseline: In or out of line?

    NARCIS (Netherlands)

    Jimmink BA; Folkert RJM; Thomas R; Beck JP; Eerdt MM van; Elzenga HE; Hoek KW van der; Hoen A; Peek CJ; LED; KMD; NMD; LVM; RIM; LDL

    2004-01-01

    The European Commission is constructing a strategy on air pollution within the Clean Air For Europe (CAFE) programme. This strategy will be based on assessments using the RAINS model for different policy ambitions where the CAFE baseline scenario and control strategies are employed. The Netherlands

  5. Emergency Response Capability Baseline Needs Assessment - Requirements Document

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, J A

    2016-10-04

    This document was prepared by John A. Sharry, LLNL Fire Marshal and LLNL Division Leader for Fire Protection and reviewed by LLNL Emergency Management Department Head James Colson. The document follows and expands upon the format and contents of the DOE Model Fire Protection Baseline Capabilities Assessment document contained on the DOE Fire Protection Web Site, but only addresses emergency response.

  6. Heavy quark production as a baseline for the quarkonium production

    International Nuclear Information System (INIS)

    Gay Ducati, M.B.; Mackedanz, L.F.

    2003-01-01

    In this contribution we analyze the energy dependence of the ratio σ J/ψ /σ DY , as well as the ratio (σ J/ψ /σ QQ -bar), in pA and AA processes, considering the high density effects expected to be present in the high energy collisions. We verify that a large quarkonium suppression is predicted if these effects are included in the calculations. Moreover, we demonstrate that the pA process can be used to make it evident and to estimate the magnitude of the high density effects. (author)

  7. NOAA GOES-R Series Advanced Baseline Imager (ABI) Level 2+ Cloud and Moisture Imagery Products (CMIP)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Cloud and Moisture Imagery product contains one or more Earth-view images with pixel values identifying brightness values that are scaled to support visual...

  8. Reconsidering Cluster Bias in Multilevel Data: A Monte Carlo Comparison of Free and Constrained Baseline Approaches.

    Science.gov (United States)

    Guenole, Nigel

    2018-01-01

    The test for item level cluster bias examines the improvement in model fit that results from freeing an item's between level residual variance from a baseline model with equal within and between level factor loadings and between level residual variances fixed at zero. A potential problem is that this approach may include a misspecified unrestricted model if any non-invariance is present, but the log-likelihood difference test requires that the unrestricted model is correctly specified. A free baseline approach where the unrestricted model includes only the restrictions needed for model identification should lead to better decision accuracy, but no studies have examined this yet. We ran a Monte Carlo study to investigate this issue. When the referent item is unbiased, compared to the free baseline approach, the constrained baseline approach led to similar true positive (power) rates but much higher false positive (Type I error) rates. The free baseline approach should be preferred when the referent indicator is unbiased. When the referent assumption is violated, the false positive rate was unacceptably high for both free and constrained baseline approaches, and the true positive rate was poor regardless of whether the free or constrained baseline approach was used. Neither the free or constrained baseline approach can be recommended when the referent indicator is biased. We recommend paying close attention to ensuring the referent indicator is unbiased in tests of cluster bias. All Mplus input and output files, R, and short Python scripts used to execute this simulation study are uploaded to an open access repository.

  9. Informed baseline subtraction of proteomic mass spectrometry data aided by a novel sliding window algorithm.

    Science.gov (United States)

    Stanford, Tyman E; Bagley, Christopher J; Solomon, Patty J

    2016-01-01

    Proteomic matrix-assisted laser desorption/ionisation (MALDI) linear time-of-flight (TOF) mass spectrometry (MS) may be used to produce protein profiles from biological samples with the aim of discovering biomarkers for disease. However, the raw protein profiles suffer from several sources of bias or systematic variation which need to be removed via pre-processing before meaningful downstream analysis of the data can be undertaken. Baseline subtraction, an early pre-processing step that removes the non-peptide signal from the spectra, is complicated by the following: (i) each spectrum has, on average, wider peaks for peptides with higher mass-to-charge ratios ( m / z ), and (ii) the time-consuming and error-prone trial-and-error process for optimising the baseline subtraction input arguments. With reference to the aforementioned complications, we present an automated pipeline that includes (i) a novel 'continuous' line segment algorithm that efficiently operates over data with a transformed m / z -axis to remove the relationship between peptide mass and peak width, and (ii) an input-free algorithm to estimate peak widths on the transformed m / z scale. The automated baseline subtraction method was deployed on six publicly available proteomic MS datasets using six different m/z-axis transformations. Optimality of the automated baseline subtraction pipeline was assessed quantitatively using the mean absolute scaled error (MASE) when compared to a gold-standard baseline subtracted signal. Several of the transformations investigated were able to reduce, if not entirely remove, the peak width and peak location relationship resulting in near-optimal baseline subtraction using the automated pipeline. The proposed novel 'continuous' line segment algorithm is shown to far outperform naive sliding window algorithms with regard to the computational time required. The improvement in computational time was at least four-fold on real MALDI TOF-MS data and at least an order of

  10. Baseline assessment of fish communities of the Flower Garden Banks

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The work developed baseline information on fish and benthic communities within the Flower Garden Banks National Marine Sanctuary (FGBNMS). Surveys employed diving,...

  11. OCRWM baseline management procedure for document identifiers

    International Nuclear Information System (INIS)

    1993-03-01

    This procedure establishes a uniform numbering system (document identifier) for all Program and project technical, cost, and schedule baselines, and selected management and procurement documents developed for and controlled by the Office of Civilian Radioactive Waste Management (OCRWM) for the Civilian Radioactive Waste Management System (CRWMS). The document identifier defined in this procedure is structured to ensure that the relational integrity between configuration items (CIs) and their associated documentation and software is maintained, traceable, categorical, and retrievable for the life of the program

  12. 77 FR 31866 - Intent To Request Approval From OMB of One New Public Collection of Information: Baseline...

    Science.gov (United States)

    2012-05-30

    ... From OMB of One New Public Collection of Information: Baseline Assessment for Security Enhancement... across public transportation systems. TSA developed the Baseline Assessment for Security Enhancement... be used as follows: 1. To develop a baseline understanding of a public transportation agency's...

  13. Baseline levels of melamine in food items sold in Canada. II. Egg, soy, vegetable, fish and shrimp products.

    Science.gov (United States)

    Tittlemier, Sheryl A; Lau, Benjamin P-Y; Ménard, Cathie; Corrigan, Catherine; Sparling, Melissa; Gaertner, Dean; Cao, Xu-Liang; Dabeka, Bob; Hilts, Carla

    2010-01-01

    A variety of egg-containing, soy-based, fish, shrimp and vegetable products sold in Canada were analysed for melamine (MEL) using a sensitive solid-phase extraction LC-MS/MS analytical method. MEL was detected above the method quantification limit of 0.004 mg/kg in 98 of the 378 samples analysed. Concentrations in the various food product groups ranged 0.00507-0.247 mg/kg (egg-containing items), 0.00408-0.0479 mg/kg (soy-based meat substitutes), 0.00409-1.10 mg/kg (fish and shrimp products), and 0.00464-0.688 mg/kg (vegetable products). MEL was detected less frequently in egg- and soy-containing products. The presence of MEL in most of the Canadian Total Diet Study shrimp composites collected after 2001 suggested the residues in shrimp were caused by a relatively recent exposure to MEL. All concentrations of MEL reported were lower than the 2.5 mg/kg interim standard established for MEL in items containing milk and milk-derived ingredients and the respective maximum residue limits for cyromazine and its metabolite, melamine, in vegetables set by the Canadian Government (2009; http://www.hc-sc.gc.ca/fn-an/securit/chem-chim/melamine/qa-melamine-qr-eng.php#8 ). The consumption of foods containing these low levels of MEL does not constitute a health risk for consumers.

  14. Mixed Waste Focus Area integrated technical baseline report, Phase 1: Volume 1

    International Nuclear Information System (INIS)

    1996-01-01

    The Department of Energy (DOE) established the Mixed Waste Characterization, Treatment, and Disposal Focus Area (MWFA) to develop and facilitate implementation of technologies required to meet the Department's commitments for treatment of mixed low-level and transuranic wastes. The mission of the MWFA is to provide acceptable treatment systems, developed in partnership with users and with participation of stakeholders, tribal governments, and regulators, that are capable of treating DOE's mixed waste. These treatment systems include all necessary steps such as characterization, pretreatment, and disposal. To accomplish this mission, a technical baseline is being established that forms the basis for determining which technology development activities will be supported by the MWFA. The technical baseline is the prioritized list of deficiencies, and the resulting technology development activities needed to overcome these deficiencies. This document presents Phase I of the technical baseline development process, which resulted in the prioritized list of deficiencies that the MWFA will address. A summary of the data and the assumptions upon which this work was based is included, as well as information concerning the DOE Office of Environmental Management (EM) mixed waste technology development needs. The next phase in the technical baseline development process, Phase II, will result in the identification of technology development activities that will be conducted through the MWFA to resolve the identified deficiencies

  15. SRP baseline hydrogeologic investigation: Aquifer characterization

    Energy Technology Data Exchange (ETDEWEB)

    Strom, R.N.; Kaback, D.S.

    1992-03-31

    An investigation of the mineralogy and chemistry of the principal hydrogeologic units and the geochemistry of the water in the principal aquifers at Savannah River Site (SRS) was undertaken as part of the Baseline Hydrogeologic Investigation. This investigation was conducted to provide background data for future site studies and reports and to provide a site-wide interpretation of the geology and geochemistry of the Coastal Plain Hydrostratigraphic province. Ground water samples were analyzed for major cations and anions, minor and trace elements, gross alpha and beta, tritium, stable isotopes of hydrogen, oxygen, and carbon, and carbon-14. Sediments from the well borings were analyzed for mineralogy and major and minor elements.

  16. Baseliner: An open-source, interactive tool for processing sap flux data from thermal dissipation probes

    Directory of Open Access Journals (Sweden)

    A. Christopher Oishi

    2016-01-01

    Full Text Available Estimating transpiration from woody plants using thermal dissipation sap flux sensors requires careful data processing. Currently, researchers accomplish this using spreadsheets, or by personally writing scripts for statistical software programs (e.g., R, SAS. We developed the Baseliner software to help establish a standardized protocol for processing sap flux data. Baseliner enables users to QA/QC data and process data using a combination of automated steps, visualization, and manual editing. Data processing requires establishing a zero-flow reference value, or “baseline”, which varies among sensors and with time. Since no set of algorithms currently exists to reliably QA/QC and estimate the zero-flow baseline, Baseliner provides a graphical user interface to allow visual inspection and manipulation of data. Data are first automatically processed using a set of user defined parameters. The user can then view the data for additional, manual QA/QC and baseline identification using mouse and keyboard commands. The open-source software allows for user customization of data processing algorithms as improved methods are developed.

  17. 75 FR 51990 - CenterPoint Energy-Illinois Gas Transmission Company; Notice of Baseline Filing

    Science.gov (United States)

    2010-08-24

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-80-000] CenterPoint Energy--Illinois Gas Transmission Company; Notice of Baseline Filing August 17, 2010. Take notice that on August 12, 2010, the applicant listed above submitted their baseline filing of its Statement of Operating...

  18. Nonintrusive methodology for wellness baseline profiling

    Science.gov (United States)

    Chung, Danny Wen-Yaw; Tsai, Yuh-Show; Miaou, Shaou-Gang; Chang, Walter H.; Chang, Yaw-Jen; Chen, Shia-Chung; Hong, Y. Y.; Chyang, C. S.; Chang, Quan-Shong; Hsu, Hon-Yen; Hsu, James; Yao, Wei-Cheng; Hsu, Ming-Sin; Chen, Ming-Chung; Lee, Shi-Chen; Hsu, Charles; Miao, Lidan; Byrd, Kenny; Chouikha, Mohamed F.; Gu, Xin-Bin; Wang, Paul C.; Szu, Harold

    2007-04-01

    We develop an accumulatively effective and affordable set of smart pair devices to save the exuberant expenditure for the healthcare of aging population, which will not be sustainable when all the post-war baby boomers retire (78 millions will cost 1/5~1/4 GDP in US alone). To design an accessible test-bed for distributed points of homecare, we choose two exemplars of the set to demonstrate the possibility of translation of modern military and clinical know-how, because two exemplars share identically the noninvasive algorithm adapted to the Smart Sensor-pairs for the real world persistent surveillance. Currently, the standard diagnoses for malignant tumors and diabetes disorders are blood serum tests, X-ray CAT scan, and biopsy used sometime in the physical checkup by physicians as cohort-average wellness baselines. The loss of the quality of life in making second careers productive may be caused by the missing of timeliness for correct diagnoses and easier treatments, which contributes to the one quarter of human errors generating the lawsuits against physicians and hospitals, which further escalates the insurance cost and wasteful healthcare expenditure. Such a vicious cycle should be entirely eliminated by building an "individual diagnostic aids (IDA)," similar to the trend of personalized drug, developed from daily noninvasive intelligent databases of the "wellness baseline profiling (WBP)". Since our physiology state undulates diurnally, the Nyquist anti-aliasing theory dictates a minimum twice-a-day sampling of the WBP for the IDA, which must be made affordable by means of noninvasive, unsupervised and unbiased methodology at the convenience of homes. Thus, a pair of military infrared (IR) spectral cameras has been demonstrated for the noninvasive spectrogram ratio test of the spontaneously emitted thermal radiation from a normal human body at 37°C temperature. This invisible self-emission spreads from 3 microns to 12 microns of the radiation wavelengths

  19. Energy use in pig production: an examination of current Iowa systems.

    Science.gov (United States)

    Lammers, P J; Kenealy, M D; Kliebenstein, J B; Harmon, J D; Helmers, M J; Honeyman, M S

    2012-03-01

    This paper compares energy use for different pig production systems in Iowa, a leader in US swine production. Pig production systems include not only the growth and performance of the pigs, but also the supporting infrastructure of pig production. This supporting infrastructure includes swine housing, facility management, feedstuff provision, swine diets, and manure management. Six different facility type × diet formulation × cropping sequence scenarios were modeled and compared. The baseline system examined produces 15,600 pigs annually using confinement facilities and a corn-soybean cropping sequence. Diet formulations for the baseline system were corn-soybean meal diets that included the synthetic AA l-lysine and exogenous phytase. The baseline system represents the majority of current US pork production in the Upper Midwest, where most US swine are produced. This system was found to require 744.6 MJ per 136-kg market pig. An alternative system that uses bedded hoop barns for grow-finish pigs and gestating sows would require 3% less (720.8 MJ) energy per 136-kg market pig. When swine production systems were assessed, diet type and feed ingredient processing were the major influences on energy use, accounting for 61 and 79% of total energy in conventional and hoop barn-based systems, respectively. Improving feed efficiency and better matching the diet formulation with the thermal environment and genetic potential are thus key aspects of reducing energy use by pig production, particularly in a hoop barn-based system. The most energy-intensive aspect of provisioning pig feed is the production of synthetic N for crop production; thus, effectively recycling manure nutrients to cropland is another important avenue for future research. Almost 25% of energy use by a conventional farrow-to-finish pig production system is attributable to operation of the swine buildings. Developing strategies to minimize energy use for heating and ventilation of swine buildings while

  20. Abstract: Notes from the Field: Establishing Baseline Data for ...

    African Journals Online (AJOL)

    Abstract: Notes from the Field: Establishing Baseline Data for Pressure Ulcers in a Rwandan Intensive Care Unit. Gedeon Mutabazi, Jessie Silver. Abstract. Abstract. Background Pressure ulcers are a common iatrogenic medical problem. Pressure ulcers increase the morbidity and mortality of hospitalized patients as well as ...