WorldWideScience

Sample records for reduction software package

  1. ldr: An R Software Package for Likelihood-Based Su?cient Dimension Reduction

    Directory of Open Access Journals (Sweden)

    Kofi Placid Adragni

    2014-11-01

    Full Text Available In regression settings, a su?cient dimension reduction (SDR method seeks the core information in a p-vector predictor that completely captures its relationship with a response. The reduced predictor may reside in a lower dimension d < p, improving ability to visualize data and predict future observations, and mitigating dimensionality issues when carrying out further analysis. We introduce ldr, a new R software package that implements three recently proposed likelihood-based methods for SDR: covariance reduction, likelihood acquired directions, and principal fitted components. All three methods reduce the dimensionality of the data by pro jection into lower dimensional subspaces. The package also implements a variable screening method built upon principal ?tted components which makes use of ?exible basis functions to capture the dependencies between the predictors and the response. Examples are given to demonstrate likelihood-based SDR analyses using ldr, including estimation of the dimension of reduction subspaces and selection of basis functions. The ldr package provides a framework that we hope to grow into a comprehensive library of likelihood-based SDR methodologies.

  2. Counting radon tracks in Makrofol detectors with the 'image reduction and analysis facility' (IRAF) software package

    International Nuclear Information System (INIS)

    Hernandez, F.; Gonzalez-Manrique, S.; Karlsson, L.; Hernandez-Armas, J.; Aparicio, A.

    2007-01-01

    Makrofol detectors are commonly used for long-term radon ( 222 Rn) measurements in houses, schools and workplaces. The use of this type of passive detectors for the determination of radon concentrations requires the counting of the nuclear tracks produced by alpha particles on the detecting material. The 'image reduction and analysis facility' (IRAF) software package is a piece of software commonly used in astronomical applications. It allows detailed counting and mapping of sky sections where stars are grouped very closely, even forming clusters. In order to count the nuclear tracks in our Makrofol radon detectors, we have developed an inter-disciplinary application that takes advantage of the similitude that exist between counting stars in a dark sky and tracks in a track-etch detector. Thus, a low cost semi-automatic system has been set up in our laboratory which utilises a commercially available desktop scanner and the IRAF software package. A detailed description of the proposed semi-automatic method and its performance, in comparison to ocular counting, is described in detail here. In addition, the calibration factor for this procedure, 2.97+/-0.07kBqm -3 htrack -1 cm 2 , has been calculated based on the results obtained from exposing 46 detectors to certified radon concentrations. Furthermore, the results of a preliminary radon survey carried out in 62 schools in Tenerife island (Spain), using Makrofol detectors, counted with the mentioned procedure, are briefly presented. The results reported here indicate that the developed procedure permits a fast, accurate and unbiased determination of the radon tracks in a large number of detectors. The measurements carried out in the schools showed that the radon concentrations in at least 12 schools were above 200Bqm -3 and, in two of them, above 400Bqm -3 . Further studies should be performed at those schools following the European Union recommendations about radon concentrations in buildings

  3. MARS software package status

    International Nuclear Information System (INIS)

    Azhgirej, I.L.; Talanov, V.V.

    2000-01-01

    The MARS software package is intended for simulating the nuclear-electromagnetic cascades and the secondary neutrons and muons transport in the heterogeneous medium of arbitrary complexity in the magnetic fields presence. The inclusive approach to describing the particle production in the nuclear and electromagnetic interactions and by the unstable particles decay is realized in the package. The MARS software package was actively applied for solving various radiation physical problems [ru

  4. The Caviar software package for the astrometric reduction of Cassini ISS images: description and examples

    Science.gov (United States)

    Cooper, N. J.; Lainey, V.; Meunier, L.-E.; Murray, C. D.; Zhang, Q.-F.; Baillie, K.; Evans, M. W.; Thuillot, W.; Vienne, A.

    2018-02-01

    Aims: Caviar is a software package designed for the astrometric measurement of natural satellite positions in images taken using the Imaging Science Subsystem (ISS) of the Cassini spacecraft. Aspects of the structure, functionality, and use of the software are described, and examples are provided. The integrity of the software is demonstrated by generating new measurements of the positions of selected major satellites of Saturn, 2013-2016, along with their observed minus computed (O-C) residuals relative to published ephemerides. Methods: Satellite positions were estimated by fitting a model to the imaged limbs of the target satellites. Corrections to the nominal spacecraft pointing were computed using background star positions based on the UCAC5 and Tycho2 star catalogues. UCAC5 is currently used in preference to Gaia-DR1 because of the availability of proper motion information in UCAC5. Results: The Caviar package is available for free download. A total of 256 new astrometric observations of the Saturnian moons Mimas (44), Tethys (58), Dione (55), Rhea (33), Iapetus (63), and Hyperion (3) have been made, in addition to opportunistic detections of Pandora (20), Enceladus (4), Janus (2), and Helene (5), giving an overall total of 287 new detections. Mean observed-minus-computed residuals for the main moons relative to the JPL SAT375 ephemeris were - 0.66 ± 1.30 pixels in the line direction and 0.05 ± 1.47 pixels in the sample direction. Mean residuals relative to the IMCCE NOE-6-2015-MAIN-coorb2 ephemeris were -0.34 ± 0.91 pixels in the line direction and 0.15 ± 1.65 pixels in the sample direction. The reduced astrometric data are provided in the form of satellite positions for each image. The reference star positions are included in order to allow reprocessing at some later date using improved star catalogues, such as later releases of Gaia, without the need to re-estimate the imaged star positions. The Caviar software is available for free download from: ftp://ftp://ftp.imcce.fr/pub/softwares

  5. The Ettention software package

    International Nuclear Information System (INIS)

    Dahmen, Tim; Marsalek, Lukas; Marniok, Nico; Turoňová, Beata; Bogachev, Sviatoslav; Trampert, Patrick; Nickels, Stefan; Slusallek, Philipp

    2016-01-01

    We present a novel software package for the problem “reconstruction from projections” in electron microscopy. The Ettention framework consists of a set of modular building-blocks for tomographic reconstruction algorithms. The well-known block iterative reconstruction method based on Kaczmarz algorithm is implemented using these building-blocks, including adaptations specific to electron tomography. Ettention simultaneously features (1) a modular, object-oriented software design, (2) optimized access to high-performance computing (HPC) platforms such as graphic processing units (GPU) or many-core architectures like Xeon Phi, and (3) accessibility to microscopy end-users via integration in the IMOD package and eTomo user interface. We also provide developers with a clean and well-structured application programming interface (API) that allows for extending the software easily and thus makes it an ideal platform for algorithmic research while hiding most of the technical details of high-performance computing. - Highlights: • Novel software package for “reconstruction from projections” in electron microscopy. • Support for high-resolution reconstructions on iterative reconstruction algorithms. • Support for CPU, GPU and Xeon Phi. • Integration in the IMOD software. • Platform for algorithm researchers: object oriented, modular design.

  6. The Ettention software package

    Energy Technology Data Exchange (ETDEWEB)

    Dahmen, Tim, E-mail: Tim.Dahmen@dfki.de [German Research Center for Artificial Intelligence GmbH (DFKI), 66123 Saarbrücken (Germany); Saarland University, 66123 Saarbrücken (Germany); Marsalek, Lukas [Eyen SE, Na Nivách 1043/16, 141 00 Praha 4 (Czech Republic); Saarland University, 66123 Saarbrücken (Germany); Marniok, Nico [Saarland University, 66123 Saarbrücken (Germany); Turoňová, Beata [Saarland University, 66123 Saarbrücken (Germany); IMPRS-CS, Max-Planck Institute for Informatics, Campus E 1.4, 66123 Saarbrücken (Germany); Bogachev, Sviatoslav [Saarland University, 66123 Saarbrücken (Germany); Trampert, Patrick; Nickels, Stefan [German Research Center for Artificial Intelligence GmbH (DFKI), 66123 Saarbrücken (Germany); Slusallek, Philipp [German Research Center for Artificial Intelligence GmbH (DFKI), 66123 Saarbrücken (Germany); Saarland University, 66123 Saarbrücken (Germany)

    2016-02-15

    We present a novel software package for the problem “reconstruction from projections” in electron microscopy. The Ettention framework consists of a set of modular building-blocks for tomographic reconstruction algorithms. The well-known block iterative reconstruction method based on Kaczmarz algorithm is implemented using these building-blocks, including adaptations specific to electron tomography. Ettention simultaneously features (1) a modular, object-oriented software design, (2) optimized access to high-performance computing (HPC) platforms such as graphic processing units (GPU) or many-core architectures like Xeon Phi, and (3) accessibility to microscopy end-users via integration in the IMOD package and eTomo user interface. We also provide developers with a clean and well-structured application programming interface (API) that allows for extending the software easily and thus makes it an ideal platform for algorithmic research while hiding most of the technical details of high-performance computing. - Highlights: • Novel software package for “reconstruction from projections” in electron microscopy. • Support for high-resolution reconstructions on iterative reconstruction algorithms. • Support for CPU, GPU and Xeon Phi. • Integration in the IMOD software. • Platform for algorithm researchers: object oriented, modular design.

  7. PIV Data Validation Software Package

    Science.gov (United States)

    Blackshire, James L.

    1997-01-01

    A PIV data validation and post-processing software package was developed to provide semi-automated data validation and data reduction capabilities for Particle Image Velocimetry data sets. The software provides three primary capabilities including (1) removal of spurious vector data, (2) filtering, smoothing, and interpolating of PIV data, and (3) calculations of out-of-plane vorticity, ensemble statistics, and turbulence statistics information. The software runs on an IBM PC/AT host computer working either under Microsoft Windows 3.1 or Windows 95 operating systems.

  8. The NOD3 software package: A graphical user interface-supported reduction package for single-dish radio continuum and polarisation observations

    Science.gov (United States)

    Müller, Peter; Krause, Marita; Beck, Rainer; Schmidt, Philip

    2017-10-01

    Context. The venerable NOD2 data reduction software package for single-dish radio continuum observations, which was developed for use at the 100-m Effelsberg radio telescope, has been successfully applied over many decades. Modern computing facilities, however, call for a new design. Aims: We aim to develop an interactive software tool with a graphical user interface for the reduction of single-dish radio continuum maps. We make a special effort to reduce the distortions along the scanning direction (scanning effects) by combining maps scanned in orthogonal directions or dual- or multiple-horn observations that need to be processed in a restoration procedure. The package should also process polarisation data and offer the possibility to include special tasks written by the individual user. Methods: Based on the ideas of the NOD2 package we developed NOD3, which includes all necessary tasks from the raw maps to the final maps in total intensity and linear polarisation. Furthermore, plot routines and several methods for map analysis are available. The NOD3 package is written in Python, which allows the extension of the package via additional tasks. The required data format for the input maps is FITS. Results: The NOD3 package is a sophisticated tool to process and analyse maps from single-dish observations that are affected by scanning effects from clouds, receiver instabilities, or radio-frequency interference. The "basket-weaving" tool combines orthogonally scanned maps into a final map that is almost free of scanning effects. The new restoration tool for dual-beam observations reduces the noise by a factor of about two compared to the NOD2 version. Combining single-dish with interferometer data in the map plane ensures the full recovery of the total flux density. Conclusions: This software package is available under the open source license GPL for free use at other single-dish radio telescopes of the astronomical community. The NOD3 package is designed to be

  9. ORNL's DCAL software package

    International Nuclear Information System (INIS)

    Eckerman, K.F.

    2007-01-01

    Oak Ridge National Laboratory has released its Dose and Risk Calculation software, DCAL. DCAL, developed with the support of the U.S. Environmental Protection Agency, consists of a series of computational modules, driven in either an interactive or a batch mode for computation of dose and risk coefficients from intakes of radionuclides or exposure to radionuclides in environmental media. The software package includes extensive libraries of biokinetic and dosimetric data that represent the current state of the art. The software has unique capability for addressing intakes of radionuclides by non-adults. DCAL runs as 32-bit extended DOS and console applications under Windows 98/NT/2000/XP. It is intended for users familiar with the basic elements of computational radiation dosimetry. Components of DCAL have been used to prepare U.S. Environmental Protection Agency's Federal Guidance Reports 12 and 13 and several publications of the International Commission on Radiological Protection. (author)

  10. The Ettention software package.

    Science.gov (United States)

    Dahmen, Tim; Marsalek, Lukas; Marniok, Nico; Turoňová, Beata; Bogachev, Sviatoslav; Trampert, Patrick; Nickels, Stefan; Slusallek, Philipp

    2016-02-01

    We present a novel software package for the problem "reconstruction from projections" in electron microscopy. The Ettention framework consists of a set of modular building-blocks for tomographic reconstruction algorithms. The well-known block iterative reconstruction method based on Kaczmarz algorithm is implemented using these building-blocks, including adaptations specific to electron tomography. Ettention simultaneously features (1) a modular, object-oriented software design, (2) optimized access to high-performance computing (HPC) platforms such as graphic processing units (GPU) or many-core architectures like Xeon Phi, and (3) accessibility to microscopy end-users via integration in the IMOD package and eTomo user interface. We also provide developers with a clean and well-structured application programming interface (API) that allows for extending the software easily and thus makes it an ideal platform for algorithmic research while hiding most of the technical details of high-performance computing. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Counting radon tracks in Makrofol detectors with the 'image reduction and analysis facility' (IRAF) software package

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, F. [Laboratorio de Fisica Medica y Radioactividad Ambiental, Departamento de Medicina Fisica y Farmacologia, Universidad de La Laguna, 38320 La Laguna, Tenerife (Spain)]. E-mail: fimerall@ull.es; Gonzalez-Manrique, S. [Laboratorio de Fisica Medica y Radioactividad Ambiental, Departamento de Medicina Fisica y Farmacologia, Universidad de La Laguna, 38320 La Laguna, Tenerife (Spain); Karlsson, L. [Laboratorio de Fisica Medica y Radioactividad Ambiental, Departamento de Medicina Fisica y Farmacologia, Universidad de La Laguna, 38320 La Laguna, Tenerife (Spain); Hernandez-Armas, J. [Laboratorio de Fisica Medica y Radioactividad Ambiental, Departamento de Medicina Fisica y Farmacologia, Universidad de La Laguna, 38320 La Laguna, Tenerife (Spain); Aparicio, A. [Instituto de Astrofisica de Canarias, 38200 La Laguna, Tenerife (Spain); Departamento de Astrofisica, Universidad de La Laguna. Avenida. Astrofisico Francisco Sanchez s/n, 38071 La Laguna, Tenerife (Spain)

    2007-03-15

    Makrofol detectors are commonly used for long-term radon ({sup 222}Rn) measurements in houses, schools and workplaces. The use of this type of passive detectors for the determination of radon concentrations requires the counting of the nuclear tracks produced by alpha particles on the detecting material. The 'image reduction and analysis facility' (IRAF) software package is a piece of software commonly used in astronomical applications. It allows detailed counting and mapping of sky sections where stars are grouped very closely, even forming clusters. In order to count the nuclear tracks in our Makrofol radon detectors, we have developed an inter-disciplinary application that takes advantage of the similitude that exist between counting stars in a dark sky and tracks in a track-etch detector. Thus, a low cost semi-automatic system has been set up in our laboratory which utilises a commercially available desktop scanner and the IRAF software package. A detailed description of the proposed semi-automatic method and its performance, in comparison to ocular counting, is described in detail here. In addition, the calibration factor for this procedure, 2.97+/-0.07kBqm{sup -3}htrack{sup -1}cm{sup 2}, has been calculated based on the results obtained from exposing 46 detectors to certified radon concentrations. Furthermore, the results of a preliminary radon survey carried out in 62 schools in Tenerife island (Spain), using Makrofol detectors, counted with the mentioned procedure, are briefly presented. The results reported here indicate that the developed procedure permits a fast, accurate and unbiased determination of the radon tracks in a large number of detectors. The measurements carried out in the schools showed that the radon concentrations in at least 12 schools were above 200Bqm{sup -3} and, in two of them, above 400Bqm{sup -3}. Further studies should be performed at those schools following the European Union recommendations about radon concentrations in

  12. Nested Cohort - R software package

    Science.gov (United States)

    NestedCohort is an R software package for fitting Kaplan-Meier and Cox Models to estimate standardized survival and attributable risks for studies where covariates of interest are observed on only a sample of the cohort.

  13. Packaging of control system software

    International Nuclear Information System (INIS)

    Zagar, K.; Kobal, M.; Saje, N.; Zagar, A.; Sabjan, R.; Di Maio, F.; Stepanov, D.

    2012-01-01

    Control system software consists of several parts - the core of the control system, drivers for integration of devices, configuration for user interfaces, alarm system, etc. Once the software is developed and configured, it must be installed to computers where it runs. Usually, it is installed on an operating system whose services it needs, and also in some cases dynamically links with the libraries it provides. Operating system can be quite complex itself - for example, a typical Linux distribution consists of several thousand packages. To manage this complexity, we have decided to rely on Red Hat Package Management system (RPM) to package control system software, and also ensure it is properly installed (i.e., that dependencies are also installed, and that scripts are run after installation if any additional actions need to be performed). As dozens of RPM packages need to be prepared, we are reducing the amount of effort and improving consistency between packages through a Maven-based infrastructure that assists in packaging (e.g., automated generation of RPM SPEC files, including automated identification of dependencies). So far, we have used it to package EPICS, Control System Studio (CSS) and several device drivers. We perform extensive testing on Red Hat Enterprise Linux 5.5, but we have also verified that packaging works on CentOS and Scientific Linux. In this article, we describe in greater detail the systematic system of packaging we are using, and its particular application for the ITER CODAC Core System. (authors)

  14. The CASA Software Package

    Science.gov (United States)

    Petry, Dirk

    2018-03-01

    CASA is the standard science data analysis package for ALMA and VLA but it can also be used for the analysis of data from other observatories. In this talk, I will give an overview of the structure and features of CASA, who develops it, and the present status and plans, and then show typical analysis workflows for ALMA data with special emphasis on the handling of single dish data and its combination with interferometric data.

  15. Software design practice using two SCADA software packages

    DEFF Research Database (Denmark)

    Basse, K.P.; Christensen, Georg Kronborg; Frederiksen, P. K.

    1996-01-01

    Typical software development for manufacturing control is done either by specialists with consideral real-time programming experience or done by the adaptation of standard software packages for manufacturing control. After investigation and test of two commercial software packages: "InTouch" and ......Touch" and "Fix", it is argued, that a more efficient software solution can be achieved by utilising an integrated specification for SCADA and PLC-programming. Experiences gained from process control is planned investigated for descrete parts manufacturing....

  16. Package-based software development

    NARCIS (Netherlands)

    Jonge, de M.; Chroust, G.; Hofer, C.

    2003-01-01

    The main goal of component-based software engineering is to decrease development time and development costs of software systems, by reusing prefabricated building blocks. Here we focus on software reuse within the implementation of such component-based applications, and on the corresponding software

  17. Intercomparison of gamma ray analysis software packages

    International Nuclear Information System (INIS)

    1998-04-01

    The IAEA undertook an intercomparison exercise to review available software for gamma ray spectra analysis. This document describes the methods used in the intercomparison exercise, characterizes the software packages reviewed and presents the results obtained. Only direct results are given without any recommendation for a particular software or method for gamma ray spectra analysis

  18. Intercomparison of alpha particle spectrometry software packages

    International Nuclear Information System (INIS)

    1999-08-01

    Software has reached an important level as the 'logical controller' at different levels, from a single instrument to an entire computer-controlled experiment. This is also the case for software packages in nuclear instruments and experiments. In particular, because of the range of applications of alpha-particle spectrometry, software packages in this field are often used. It is the aim of this intercomparison to test and describe the abilities of four such software packages. The main objectives of the intercomparison were the ability of the programs to determine the peak areas and the peak area uncertainties, and the statistical control and stability of reported results. In this report, the task, methods and results of the intercomparison are presented in order to asist the potential users of such software and to stimulate the development of even better alpha-particle spectrum analysis software

  19. Intercomparison of PIXE spectrometry software packages

    International Nuclear Information System (INIS)

    2003-02-01

    During the year 2000, an exercise was organized to make a intercomparison of widely available software packages for analysis of particle induced X ray emission (PIXE) spectra. This TECDOC describes the method used in this intercomparison exercise and presents the results obtained. It also gives a general overview of the participating software packages. This includes basic information on their user interface, graphical presentation capabilities, physical phenomena taken in account, way of presenting results, etc. No recommendation for a particular software package or method for spectrum analysis is given. It is intended that the readers reach their own conclusions and make their own choices, according to their specific needs. This TECDOC will be useful to anyone involved in PIXE spectrum analysis. This TECDOC includes a companion CD with the complete set of test spectra used for intercomparison. The test spectra on this CD can be used to test any PIXE spectral analysis software package

  20. Introduction to Software Packages. [Final Report.

    Science.gov (United States)

    Frankel, Sheila, Ed.; And Others

    This document provides an introduction to applications computer software packages that support functional managers in government and encourages the use of such packages as an alternative to in-house development. A review of current application areas includes budget/project management, financial management/accounting, payroll, personnel,…

  1. Software packages for food engineering needs

    OpenAIRE

    Abakarov, Alik

    2011-01-01

    The graphic user interface (GUI) software packages “ANNEKs” and “OPT-PROx” are developed to meet food engineering needs. “OPT-RROx” (OPTimal PROfile) is software developed to carry out thermal food processing optimization based on the variable retort temperature processing and global optimization technique. “ANNEKs” (Artificial Neural Network Enzyme Kinetics) is software designed for determining the kinetics of enzyme hydrolysis of protein at different initial reaction parameters based on the...

  2. Software package as an information center product

    International Nuclear Information System (INIS)

    Butler, M.K.

    1977-01-01

    The Argonne Code Center serves as a software exchange and information center for the U.S. Energy Research and Development Administration and the Nuclear Regulatory Commission. The goal of the Center's program is to provide a means for sharing of software among agency offices and contractors, and for transferring computing applications and technology, developed within the agencies, to the information-processing community. A major activity of the Code Center is the acquisition, review, testing, and maintenance of a collection of software--computer systems, applications programs, subroutines, modules, and data compilations--prepared by agency offices and contractors to meet programmatic needs. A brief review of the history of computer program libraries and software sharing is presented to place the Code Center activity in perspective. The state-of-the-art discussion starts off with an appropriate definition of the term software package, together with descriptions of recommended package contents and the Carter's package evaluation activity. An effort is made to identify the various users of the product, to enumerate their individual needs, to document the Center's efforts to meet these needs and the ongoing interaction with the user community. Desirable staff qualifications are considered, and packaging problems, reviewed. The paper closes with a brief look at recent developments and a forecast of things to come. 2 tables

  3. Software Package STATISTICA and Educational Process

    Directory of Open Access Journals (Sweden)

    Demidova Liliya

    2016-01-01

    Full Text Available The paper describes the main aspects of application of the software package STATISTICA in the educational process. Technologies of data mining which can be useful for students researches have been considered. The main tools of these technologies have been discussed.

  4. Consys Linear Control System Design Software Package

    International Nuclear Information System (INIS)

    Diamantidis, Z.

    1987-01-01

    This package is created in order to help engineers, researchers, students and all who work on linear control systems. The software includes all time and frequency domain analysises, spectral analysises and networks, active filters and regulators design aids. The programmes are written on Hewlett Packard computer in Basic 4.0

  5. SPADE - software package to aid diffraction experiments

    International Nuclear Information System (INIS)

    Farren, J.; Giltrap, J.W.

    1978-10-01

    A software package is described which enables the DEC PDP-11/03 microcomputer to execute several different X-ray diffraction experiments and other similar experiments where stepper motors are driven and data is gathered and processed in real time. (author)

  6. Human-machine interface software package

    International Nuclear Information System (INIS)

    Liu, D.K.; Zhang, C.Z.

    1992-01-01

    The Man-Machine Interface software Package (MMISP) is designed to configure the console software of PLS 60 Mev LINAC control system. The control system of PLS 60 Mev LINAC is a distributed control system which includes the main computer (Intel 310) four local station, and two sets of industrial level console computer. The MMISP provides the operator with the display page editor, various I/O configuration such as digital signals In/Out, analog signal In/Out, waveform TV graphic display, and interactive with operator through graphic picture display, voice explanation, and touch panel. This paper describes its function and application. (author)

  7. THE SOFTWARE PACKAGE FOR DATA STREAM SCRAMBLING

    Directory of Open Access Journals (Sweden)

    P. A. Kadiev

    2016-01-01

    Full Text Available Abstract. It is proposed a software package for multivariate stepwise transformation of the text flow in order to increase resistance to protect against unauthorized access, and a package to restore the converted text. The basis of the proposals: the formation of nxn-array from the elements of a data flow, preliminary transposition of the array elements to form an array, each row and each column of which includes one and one only element from each row and each column of the source array, following reading on the options selected by the user.Package for direct conversion includes: a module for forming an array from the input flow; transposition module of array elements according to the scheme of Latin squares; reading module of rows or columns of the array to one of the following algorithms: sequential reading; reading of rows or columns with even indices and then odd ones;reading the row or column with odd indices, and then the even; reading at random route, which is generated by the program; reading at the route determined by the user.Package for restoring of the original message by the inverse transform comprises: a channel array forming module from the data flow; recovery module from the channel array - the array of Latin square type; the original array module; the original message restoring module. 

  8. Browndye: A software package for Brownian dynamics

    Science.gov (United States)

    Huber, Gary A.; McCammon, J. Andrew

    2010-11-01

    A new software package, Browndye, is presented for simulating the diffusional encounter of two large biological molecules. It can be used to estimate second-order rate constants and encounter probabilities, and to explore reaction trajectories. Browndye builds upon previous knowledge and algorithms from software packages such as UHBD, SDA, and Macrodox, while implementing algorithms that scale to larger systems. Program summaryProgram title: Browndye Catalogue identifier: AEGT_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEGT_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: MIT license, included in distribution No. of lines in distributed program, including test data, etc.: 143 618 No. of bytes in distributed program, including test data, etc.: 1 067 861 Distribution format: tar.gz Programming language: C++, OCaml ( http://caml.inria.fr/) Computer: PC, Workstation, Cluster Operating system: Linux Has the code been vectorised or parallelized?: Yes. Runs on multiple processors with shared memory using pthreads RAM: Depends linearly on size of physical system Classification: 3 External routines: uses the output of APBS [1] ( http://www.poissonboltzmann.org/apbs/) as input. APBS must be obtained and installed separately. Expat 2.0.1, CLAPACK, ocaml-expat, Mersenne Twister. These are included in the Browndye distribution. Nature of problem: Exploration and determination of rate constants of bimolecular interactions involving large biological molecules. Solution method: Brownian dynamics with electrostatic, excluded volume, van der Waals, and desolvation forces. Running time: Depends linearly on size of physical system and quadratically on precision of results. The included example executes in a few minutes.

  9. STAR-GENERIS - a software package for information processing

    International Nuclear Information System (INIS)

    Felkel, L.

    1985-01-01

    Man-machine-communication in electrical power plants is increasingly based on the capabilities of minicomputers. Rather than just displaying raw process data more complex processing is done to aid operators by improving information quality. Advanced operator aids for nuclear power plants are, e.g. alarm reduction, disturbance analysis and expert systems. Operator aids use complex combinations and computations of plant signals, which have to be described in a formal and homogeneous way. The design of such computer-based information systems requires extensive software and engineering efforts. The STAR software concept reduces the software effort to a minimum by proving an advanced program package which facilitates specification and implementation of engineering know-how necessary for sophisticated operator aids. (orig./HP) [de

  10. Software Package for the Technical Support Centre

    International Nuclear Information System (INIS)

    Tomisa, T.; Skanata, D.; Sucic, B.

    2002-01-01

    The continued radiological surveillance system has been technically improved during the last two years by establishing 11 new automatic stations, so that there are currently 14 locations with installed gamma-monitors for air radiation monitoring on the Croatian national territory. Given that the original system had been designed primarily for gathering data for off-line treatment with the purpose of statistical analyses, the contemporary Radiological Early Warning System (SPRU) approach has demanded developing of a new software by the Technical Support Centre (TPC) in order to allow operators interactive work in the case of emergency situations. The outcome of this development is a software package called DORAP (Automatic Radiological Station Remote Reading), which brings together automatic functions of continual data gathering, daily production of the standard report, distribution of the report by fax, SMS (Short Message Service), SMT (Simple Mail Transfer) and FTP (File Transfer Protocol) as well as generation and distribution of alarms in the case of failure in the system or exceeding of the set radiation intensity values. (author)

  11. Accuracy of Giovanni and Marksim Software Packages for ...

    African Journals Online (AJOL)

    Accuracy of Giovanni and Marksim Software Packages for Generating Daily Rainfall Data in ... using Giovanni software over Marksim, for areas receiving bimodal rainfall regimes similar to ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  12. Software for Probabilistic Risk Reduction

    Science.gov (United States)

    Hensley, Scott; Michel, Thierry; Madsen, Soren; Chapin, Elaine; Rodriguez, Ernesto

    2004-01-01

    A computer program implements a methodology, denoted probabilistic risk reduction, that is intended to aid in planning the development of complex software and/or hardware systems. This methodology integrates two complementary prior methodologies: (1) that of probabilistic risk assessment and (2) a risk-based planning methodology, implemented in a prior computer program known as Defect Detection and Prevention (DDP), in which multiple requirements and the beneficial effects of risk-mitigation actions are taken into account. The present methodology and the software are able to accommodate both process knowledge (notably of the efficacy of development practices) and product knowledge (notably of the logical structure of a system, the development of which one seeks to plan). Estimates of the costs and benefits of a planned development can be derived. Functional and non-functional aspects of software can be taken into account, and trades made among them. It becomes possible to optimize the planning process in the sense that it becomes possible to select the best suite of process steps and design choices to maximize the expectation of success while remaining within budget.

  13. Adoption of open source digital library software packages: a survey

    OpenAIRE

    Jose, Sanjo

    2007-01-01

    Open source digital library packages are gaining popularity nowadays. To build a digital library under economical conditions open source software is preferable. This paper tries to identify the extent of adoption of open source digital library software packages in various organizations through an online survey. It lays down the findings from the survey.

  14. The SAVI Vulnerability Analysis Software Package

    International Nuclear Information System (INIS)

    Mc Aniff, R.J.; Paulus, W.K.; Key, B.; Simpkins, B.

    1987-01-01

    SAVI (Systematic Analysis of Vulnerability to Intrusion) is a new PC-based software package for modeling Physical Protection Systems (PPS). SAVI utilizes a path analysis approach based on the Adversary Sequence Diagram (ASD) methodology. A highly interactive interface allows the user to accurately model complex facilities, maintain a library of these models on disk, and calculate the most vulnerable paths through any facility. Recommendations are provided to help the user choose facility upgrades which should reduce identified path vulnerabilities. Pop-up windows throughout SAVI are used for the input and display of information. A menu at the top of the screen presents all options to the user. These options are further explained on a message line directly below the menu. A diagram on the screen graphically represents the current protection system model. All input is checked for errors, and data are presented in a logical and clear manner. Print utilities provide the user with hard copies of all information and calculated results

  15. LDR: A Package for Likelihood-Based Sufficient Dimension Reduction

    Directory of Open Access Journals (Sweden)

    R. Dennis Cook

    2011-03-01

    Full Text Available We introduce a new mlab software package that implements several recently proposed likelihood-based methods for sufficient dimension reduction. Current capabilities include estimation of reduced subspaces with a fixed dimension d, as well as estimation of d by use of likelihood-ratio testing, permutation testing and information criteria. The methods are suitable for preprocessing data for both regression and classification. Implementations of related estimators are also available. Although the software is more oriented to command-line operation, a graphical user interface is also provided for prototype computations.

  16. Software refactoring at the package level using clustering techniques

    KAUST Repository

    Alkhalid, A.

    2011-01-01

    Enhancing, modifying or adapting the software to new requirements increases the internal software complexity. Software with high level of internal complexity is difficult to maintain. Software refactoring reduces software complexity and hence decreases the maintenance effort. However, software refactoring becomes quite challenging task as the software evolves. The authors use clustering as a pattern recognition technique to assist in software refactoring activities at the package level. The approach presents a computer aided support for identifying ill-structured packages and provides suggestions for software designer to balance between intra-package cohesion and inter-package coupling. A comparative study is conducted applying three different clustering techniques on different software systems. In addition, the application of refactoring at the package level using an adaptive k-nearest neighbour (A-KNN) algorithm is introduced. The authors compared A-KNN technique with the other clustering techniques (viz. single linkage algorithm, complete linkage algorithm and weighted pair-group method using arithmetic averages). The new technique shows competitive performance with lower computational complexity. © 2011 The Institution of Engineering and Technology.

  17. International Inventory of Software Packages in the Information Field.

    Science.gov (United States)

    Keren, Carl, Ed.; Sered, Irina, Ed.

    Designed to provide guidance in selecting appropriate software for library automation, information storage and retrieval, or management of bibliographic databases, this inventory describes 188 computer software packages. The information was obtained through a questionnaire survey of 600 software suppliers and developers who were asked to describe…

  18. Comparison of PV system design software packages for urban applications

    Energy Technology Data Exchange (ETDEWEB)

    Gharakhani Siraki, Arbi; Pillay, Pragasen

    2010-09-15

    A large number of software packages are available for solar resource evaluation and PV system design. However, few of them are suitable for urban applications. In this paper a comparison has been made between two specifically designed solar tools known as the Ecotect 2010 and the PVsyst 5.05. Conclusions have been made for proper use of these packages based on their specifications and privileges. Moreover, the calculations have been repeated with HOMER software package (which is a generic tool) for the same location. The results suggest that a generic solar software tool should not be used for an urban application.

  19. An Assessment of the Library Application Software Packages in ...

    African Journals Online (AJOL)

    Journal Home > Vol 7, No 2 (2007) > ... the study examined the adopted softwares' security, compatibility/capabilities, ... The study found that most application packages available in the Nigerian automation market place are effective since they ...

  20. The experimental modification of a computer software package for ...

    African Journals Online (AJOL)

    The experimental modification of a computer software package for graphing algebraic functions. ... No Abstract Available South African Journal of Education Vol.25(2) 2005: 61-68. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  1. Software package for analysis of completely randomized block design

    African Journals Online (AJOL)

    This study is to design and develop statistical software (package), OYSP1.0 which conveniently accommodates and analyzes large mass of data emanating from experimental designs, in particular, completely Randomized Block design. Visual Basic programming is used in the design. The statistical package OYSP 1.0 ...

  2. A Characteristics Approach to the Evaluation of Economics Software Packages.

    Science.gov (United States)

    Lumsden, Keith; Scott, Alex

    1988-01-01

    Utilizes Bloom's Taxonomy to identify elements of teacher and student interest. Depicts the way in which these interests are developed into characteristics for use in analytically evaluating software. Illustrates the use of this evaluating technique by appraising the much used software package "Running the British Economy." (KO)

  3. PIV/HPIV Film Analysis Software Package

    Science.gov (United States)

    Blackshire, James L.

    1997-01-01

    A PIV/HPIV film analysis software system was developed that calculates the 2-dimensional spatial autocorrelations of subregions of Particle Image Velocimetry (PIV) or Holographic Particle Image Velocimetry (HPIV) film recordings. The software controls three hardware subsystems including (1) a Kodak Megaplus 1.4 camera and EPIX 4MEG framegrabber subsystem, (2) an IEEE/Unidex 11 precision motion control subsystem, and (3) an Alacron I860 array processor subsystem. The software runs on an IBM PC/AT host computer running either the Microsoft Windows 3.1 or Windows 95 operating system. It is capable of processing five PIV or HPIV displacement vectors per second, and is completely automated with the exception of user input to a configuration file prior to analysis execution for update of various system parameters.

  4. GPS Software Packages Deliver Positioning Solutions

    Science.gov (United States)

    2010-01-01

    "To determine a spacecraft s position, the Jet Propulsion Laboratory (JPL) developed an innovative software program called the GPS (global positioning system)-Inferred Positioning System and Orbit Analysis Simulation Software, abbreviated as GIPSY-OASIS, and also developed Real-Time GIPSY (RTG) for certain time-critical applications. First featured in Spinoff 1999, JPL has released hundreds of licenses for GIPSY and RTG, including to Longmont, Colorado-based DigitalGlobe. Using the technology, DigitalGlobe produces satellite imagery with highly precise latitude and longitude coordinates and then supplies it for uses within defense and intelligence, civil agencies, mapping and analysis, environmental monitoring, oil and gas exploration, infrastructure management, Internet portals, and navigation technology."

  5. Software Package for Optics Measurement and Correction in the LHC

    CERN Document Server

    Aiba, M; Tomas, R; Vanbavinckhove, G

    2010-01-01

    A software package has been developed for the LHC on-line optics measurement and correction. This package includes several different algorithms to measure phase advance, beta functions, dispersion, coupling parameters and even some non-linear terms. A Graphical User Interface provides visualization tools to compare measurements to model predictions, fit analytical formula, localize error sources and compute and send corrections to the hardware.

  6. Policy packages to achieve demand reduction

    International Nuclear Information System (INIS)

    Boardman, Brenda

    2005-01-01

    In many sectors and many countries, energy demand is still increasing, despite decades of policies to reduce demand. Controlling climate change is becoming more urgent, so there is a need to devise policies that will, virtually, guarantee demand reduction. This has to come from policy, at least in the UK, as the conditions do not exist, yet, when the consumers will 'pull' the market for energy efficiency or the manufacturers will use technological development to 'push' it. That virtuous circle has to be created by a mixture of consumer education and restrictions on manufacturers (for instance, permission to manufacture). The wider policy options include higher prices for energy and stronger product policies. An assessment of the effectiveness of different policy packages indicates some guiding principles, for instance that improved product policy must precede higher prices, otherwise consumers are unable to react effectively to price rises. The evidence will be assessed about the ways in which national and EU policies can either reinforce, duplicate or undermine each other. Another area of examination will be timescales: what is the time lag between the implementation of a policy (whether prices or product based) and the level of maximum reductions. In addition, the emphasis given to factors such as equity, raising investment funds and speed of delivery also influence policy design and the extent to which absolute carbon reductions can be expected

  7. Comparison of four software packages applied to a scattering problem

    DEFF Research Database (Denmark)

    Albertsen, Niels Christian; Chesneaux, Jean-Marie; Christiansen, Søren

    1999-01-01

    We investigate characteristic features of four different software packages by applying them to the numerical solution of a non-trivial physical problem in computer simulation, viz., scattering of waves from a sinusoidal boundary. The numerical method used is based on boundary collocation. This le......We investigate characteristic features of four different software packages by applying them to the numerical solution of a non-trivial physical problem in computer simulation, viz., scattering of waves from a sinusoidal boundary. The numerical method used is based on boundary collocation...

  8. Description of the IV + V System Software Package.

    Science.gov (United States)

    Microcomputers for Information Management: An International Journal for Library and Information Services, 1984

    1984-01-01

    Describes the IV + V System, a software package designed by the Institut fur Maschinelle Dokumentation for the United Nations General Information Programme and UNISIST to support automation of local information and documentation services. Principle program features and functions outlined include input/output, databank, text image, output, and…

  9. A software package for biomedical image processing and analysis

    International Nuclear Information System (INIS)

    Goncalves, J.G.M.; Mealha, O.

    1988-01-01

    The decreasing cost of computing power and the introduction of low cost imaging boards justifies the increasing number of applications of digital image processing techniques in the area of biomedicine. There is however a large software gap to be fulfilled, between the application and the equipment. The requirements to bridge this gap are twofold: good knowledge of the hardware provided and its interface to the host computer, and expertise in digital image processing and analysis techniques. A software package incorporating these two requirements was developed using the C programming language, in order to create a user friendly image processing programming environment. The software package can be considered in two different ways: as a data structure adapted to image processing and analysis, which acts as the backbone and the standard of communication for all the software; and as a set of routines implementing the basic algorithms used in image processing and analysis. Hardware dependency is restricted to a single module upon which all hardware calls are based. The data structure that was built has four main features: hierchical, open, object oriented, and object dependent dimensions. Considering the vast amount of memory needed by imaging applications and the memory available in small imaging systems, an effective image memory management scheme was implemented. This software package is being used for more than one and a half years by users with different applications. It proved to be an excellent tool for helping people to get adapted into the system, and for standardizing and exchanging software, yet preserving flexibility allowing for users' specific implementations. The philosophy of the software package is discussed and the data structure that was built is described in detail

  10. Development of a software package for solid-angle calculations using the Monte Carlo method

    International Nuclear Information System (INIS)

    Zhang, Jie; Chen, Xiulian; Zhang, Changsheng; Li, Gang; Xu, Jiayun; Sun, Guangai

    2014-01-01

    Solid-angle calculations play an important role in the absolute calibration of radioactivity measurement systems and in the determination of the activity of radioactive sources, which are often complicated. In the present paper, a software package is developed to provide a convenient tool for solid-angle calculations in nuclear physics. The proposed software calculates solid angles using the Monte Carlo method, in which a new type of variance reduction technique was integrated. The package, developed under the environment of Microsoft Foundation Classes (MFC) in Microsoft Visual C ++ , has a graphical user interface, in which, the visualization function is integrated in conjunction with OpenGL. One advantage of the proposed software package is that it can calculate the solid angle subtended by a detector with different geometric shapes (e.g., cylinder, square prism, regular triangular prism or regular hexagonal prism) to a point, circular or cylindrical source without any difficulty. The results obtained from the proposed software package were compared with those obtained from previous studies and calculated using Geant4. It shows that the proposed software package can produce accurate solid-angle values with a greater computation speed than Geant4. -- Highlights: • This software package (SAC) can give accurate solid-angle values. • SAC calculate solid angles using the Monte Carlo method and it has higher computation speed than Geant4. • A simple but effective variance reduction technique which was put forward by the authors has been applied in SAC. • A visualization function and a graphical user interface are also integrated in SAC

  11. A User-Friendly Software Package for HIFU Simulation

    Science.gov (United States)

    Soneson, Joshua E.

    2009-04-01

    A freely-distributed, MATLAB (The Mathworks, Inc., Natick, MA)-based software package for simulating axisymmetric high-intensity focused ultrasound (HIFU) beams and their heating effects is discussed. The package (HIFU_Simulator) consists of a propagation module which solves the Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation and a heating module which solves Pennes' bioheat transfer (BHT) equation. The pressure, intensity, heating rate, temperature, and thermal dose fields are computed, plotted, the output is released to the MATLAB workspace for further user analysis or postprocessing.

  12. Article I. Multi-platform Automated Software Building and Packaging

    International Nuclear Information System (INIS)

    Rodriguez, A Abad; Gomes Gouveia, V E; Meneses, D; Capannini, F; Aimar, A; Di Meglio, A

    2012-01-01

    One of the major goals of the EMI (European Middleware Initiative) project is the integration of several components of the pre-existing middleware (ARC, gLite, UNICORE and dCache) into a single consistent set of packages with uniform distributions and repositories. Those individual middleware projects have been developed in the last decade by tens of development teams and before EMI were all built and tested using different tools and dedicated services. The software, millions of lines of code, is written in several programming languages and supports multiple platforms. Therefore a viable solution ought to be able to build and test applications on multiple programming languages using common dependencies on all selected platforms. It should, in addition, package the resulting software in formats compatible with the popular Linux distributions, such as Fedora and Debian, and store them in repositories from which all EMI software can be accessed and installed in a uniform way. Despite this highly heterogeneous initial situation, a single common solution, with the aim of quickly automating the integration of the middleware products, had to be selected and implemented in a few months after the beginning of the EMI project. Because of the previous knowledge and the short time available in which to provide this common solution, the ETICS service, where the gLite middleware was already built for years, was selected. This contribution describes how the team in charge of providing a common EMI build and packaging infrastructure to the whole project has developed a homogeneous solution for releasing and packaging the EMI components from the initial set of tools used by the earlier middleware projects. An important element of the presentation is the developers experience and feedback on converging on ETICS and on the on-going work in order to finally add more widely used and supported build and packaging solutions of the Linux platforms

  13. COMPUTATIONAL MODELLING OF BUFFETING EFFECTS USING OPENFOAM SOFTWARE PACKAGE

    Directory of Open Access Journals (Sweden)

    V. T. Kalugin

    2015-01-01

    Full Text Available In this paper, the preliminary results of computational modeling of an aircraft with the airbrake deployed are presented. The calculations were performed with OpenFOAM software package. The results outlined are a part of a research project to optimise aircraft performance using a perforated airbrake. Within this stage of the project OpenFOAM software package with hybrid RANS-LES approach was tested in respect to a given configuration of the aircraft, airbrake and then has been compared with the test data. For the worst case the amplitude of the peak force acting on the tail fin can be up to 6 times higher than the average value without airbrake deployed. To reduce unsteady loads acting on the tailfin, perforation of the airbrake was proposed.

  14. Current status and future direction of the MONK software package

    International Nuclear Information System (INIS)

    Smith, Nigel; Armishaw, Malcolm; Cooper, Andrew

    2003-01-01

    The current status of the MONK criticality software package is summarized in terms of recent and current developments and envisaged directions for the future. The areas of the discussion are physics modeling, geometry modeling, source modeling, nuclear data, validation, supporting tools and customer services. In future development plan, MONK continues to be focused on meeting the short and long-term needs of the code user community. (J.P.N.)

  15. Chinshan living PRA model using NUPRA software package

    International Nuclear Information System (INIS)

    Cheng, S.-K.; Lin, T.-J.

    2004-01-01

    A living probabilistic risk assessment (PRA) model has been established for Chinshan Nuclear Power Station (BWR-4, MARK-I) using NUPRA software package. The core damage frequency due to internal events, seismic events and typhoons are evaluated in this model. The methodology and results considering the recent implementation of the 5th emergency diesel generator and automatic boron injection function are presented. The dominant sequences of this PRA model are discussed, and some possible applications of this living model are proposed. (author)

  16. Nonlinear analysis of reinforced concrete structures using software package abaqus

    OpenAIRE

    Marković Nemanja; Stojić Dragoslav; Cvetković Radovan

    2014-01-01

    Reinforced concrete (AB) is characterized by huge inhomogeneity resulting from the material characteristics of the concrete, then, quasi-brittle behavior during failure. These and other phenomena require the introduction of material nonlinearity in the modeling of reinforced concrete structures. This paper presents the modeling reinforced concrete in the software package ABAQUS. A brief theoretical overview is presented of methods such as: Concrete Damage Plasticity (CDP), Smeared Concrete Cr...

  17. A customizable software for fast reduction and analysis of large X-ray scattering data sets: applications of the new DPDAK package to small-angle X-ray scattering and grazing-incidence small-angle X-ray scattering.

    Science.gov (United States)

    Benecke, Gunthard; Wagermaier, Wolfgang; Li, Chenghao; Schwartzkopf, Matthias; Flucke, Gero; Hoerth, Rebecca; Zizak, Ivo; Burghammer, Manfred; Metwalli, Ezzeldin; Müller-Buschbaum, Peter; Trebbin, Martin; Förster, Stephan; Paris, Oskar; Roth, Stephan V; Fratzl, Peter

    2014-10-01

    X-ray scattering experiments at synchrotron sources are characterized by large and constantly increasing amounts of data. The great number of files generated during a synchrotron experiment is often a limiting factor in the analysis of the data, since appropriate software is rarely available to perform fast and tailored data processing. Furthermore, it is often necessary to perform online data reduction and analysis during the experiment in order to interactively optimize experimental design. This article presents an open-source software package developed to process large amounts of data from synchrotron scattering experiments. These data reduction processes involve calibration and correction of raw data, one- or two-dimensional integration, as well as fitting and further analysis of the data, including the extraction of certain parameters. The software, DPDAK (directly programmable data analysis kit), is based on a plug-in structure and allows individual extension in accordance with the requirements of the user. The article demonstrates the use of DPDAK for on- and offline analysis of scanning small-angle X-ray scattering (SAXS) data on biological samples and microfluidic systems, as well as for a comprehensive analysis of grazing-incidence SAXS data. In addition to a comparison with existing software packages, the structure of DPDAK and the possibilities and limitations are discussed.

  18. New software for neutron data reduction and visualization

    International Nuclear Information System (INIS)

    Worlton, T.; Chatterjee, A.; Hammonds, J.; Chen, D.; Loong, C.K.; Mikkelson, D.; Mikkelson, R.

    2001-01-01

    Development of advanced neutron sources and instruments has necessitated corresponding advances in software for neutron scattering data reduction and visualization. New sources produce datasets more rapidly, and new instruments produce large numbers of spectra. Because of the shorter collection times, users are able to make more measurements on a given sample. This rapid production of datasets requires that users be able to reduce and analyze data quickly to prevent a data bottleneck. In addition, the new sources and instruments are accommodating more users with less neutron-scattering specific expertise, which requires software that is easy to use and freely available. We have developed an Integrated Spectral Analysis Workbench (ISAW) software package to permit the rapid reduction and visualization of neutron data. It can handle large numbers of spectra and merge data from separate measurements. The data can be sorted according to any attribute and transformed in numerous ways. ISAW provides several views of the data that enable users to compare spectra and observe trends in the data. A command interpreter, which is now part of ISAW, allows scientists to easily set up a series of instrument-specific operations to reduce and visualize data automatically. ISAW is written entirely in Java to permit portability to different computer platforms and easy distribution of the software. The software was constructed using modern computer design methods to allow easy customization and improvement. ISAW currently only reads data from IPNS 'run' files, but work is underway to provide input of NeXus files. (author)

  19. New software for neutron data reduction and visualization

    Energy Technology Data Exchange (ETDEWEB)

    Worlton, T.; Chatterjee, A.; Hammonds, J.; Chen, D.; Loong, C.K. [Argonne National Laboratory, Argonne, IL (United States); Mikkelson, D.; Mikkelson, R. [Univ. of Wisconsin-Stout, Menomonie, WI (United States)

    2001-03-01

    Development of advanced neutron sources and instruments has necessitated corresponding advances in software for neutron scattering data reduction and visualization. New sources produce datasets more rapidly, and new instruments produce large numbers of spectra. Because of the shorter collection times, users are able to make more measurements on a given sample. This rapid production of datasets requires that users be able to reduce and analyze data quickly to prevent a data bottleneck. In addition, the new sources and instruments are accommodating more users with less neutron-scattering specific expertise, which requires software that is easy to use and freely available. We have developed an Integrated Spectral Analysis Workbench (ISAW) software package to permit the rapid reduction and visualization of neutron data. It can handle large numbers of spectra and merge data from separate measurements. The data can be sorted according to any attribute and transformed in numerous ways. ISAW provides several views of the data that enable users to compare spectra and observe trends in the data. A command interpreter, which is now part of ISAW, allows scientists to easily set up a series of instrument-specific operations to reduce and visualize data automatically. ISAW is written entirely in Java to permit portability to different computer platforms and easy distribution of the software. The software was constructed using modern computer design methods to allow easy customization and improvement. ISAW currently only reads data from IPNS 'run' files, but work is underway to provide input of NeXus files. (author)

  20. PINT, A Modern Software Package for Pulsar Timing

    Science.gov (United States)

    Luo, Jing; Ransom, Scott M.; Demorest, Paul; Ray, Paul S.; Stovall, Kevin; Jenet, Fredrick; Ellis, Justin; van Haasteren, Rutger; Bachetti, Matteo; NANOGrav PINT developer team

    2018-01-01

    Pulsar timing, first developed decades ago, has provided an extremely wide range of knowledge about our universe. It has been responsible for many important discoveries, such as the discovery of the first exoplanet and the orbital period decay of double neutron star systems. Currently pulsar timing is the leading technique for detecting low frequency (about 10^-9 Hertz) gravitational waves (GW) using an array of pulsars as the detectors. To achieve this goal, high precision pulsar timing data, at about nanoseconds level, is required. Most high precision pulsar timing data are analyzed using the widely adopted software TEMPO/TEMPO2. But for a robust and believable GW detection, it is important to have independent software that can cross-check the result. In this poster we present the new generation pulsar timing software PINT. This package will provide a robust system to cross check high-precision timing results, completely independent of TEMPO and TEMPO2. In addition, PINT is designed to be a package that is easy to extend and modify, through use of flexible code architecture and a modern programming language, Python, with modern technology and libraries.

  1. FRAMES Software System: Linking to the Statistical Package R

    Energy Technology Data Exchange (ETDEWEB)

    Castleton, Karl J.; Whelan, Gene; Hoopes, Bonnie L.

    2006-12-11

    This document provides requirements, design, data-file specifications, test plan, and Quality Assurance/Quality Control protocol for the linkage between the statistical package R and the Framework for Risk Analysis in Multimedia Environmental Systems (FRAMES) Versions 1.x and 2.0. The requirements identify the attributes of the system. The design describes how the system will be structured to meet those requirements. The specification presents the specific modifications to FRAMES to meet the requirements and design. The test plan confirms that the basic functionality listed in the requirements (black box testing) actually functions as designed, and QA/QC confirms that the software meets the client’s needs.

  2. SEDA: A software package for the Statistical Earthquake Data Analysis

    Science.gov (United States)

    Lombardi, A. M.

    2017-03-01

    In this paper, the first version of the software SEDA (SEDAv1.0), designed to help seismologists statistically analyze earthquake data, is presented. The package consists of a user-friendly Matlab-based interface, which allows the user to easily interact with the application, and a computational core of Fortran codes, to guarantee the maximum speed. The primary factor driving the development of SEDA is to guarantee the research reproducibility, which is a growing movement among scientists and highly recommended by the most important scientific journals. SEDAv1.0 is mainly devoted to produce accurate and fast outputs. Less care has been taken for the graphic appeal, which will be improved in the future. The main part of SEDAv1.0 is devoted to the ETAS modeling. SEDAv1.0 contains a set of consistent tools on ETAS, allowing the estimation of parameters, the testing of model on data, the simulation of catalogs, the identification of sequences and forecasts calculation. The peculiarities of routines inside SEDAv1.0 are discussed in this paper. More specific details on the software are presented in the manual accompanying the program package.

  3. Scilab software package for the study of dynamical systems

    Science.gov (United States)

    Bordeianu, C. C.; Beşliu, C.; Jipa, Al.; Felea, D.; Grossu, I. V.

    2008-05-01

    This work presents a new software package for the study of chaotic flows and maps. The codes were written using Scilab, a software package for numerical computations providing a powerful open computing environment for engineering and scientific applications. It was found that Scilab provides various functions for ordinary differential equation solving, Fast Fourier Transform, autocorrelation, and excellent 2D and 3D graphical capabilities. The chaotic behaviors of the nonlinear dynamics systems were analyzed using phase-space maps, autocorrelation functions, power spectra, Lyapunov exponents and Kolmogorov-Sinai entropy. Various well known examples are implemented, with the capability of the users inserting their own ODE. Program summaryProgram title: Chaos Catalogue identifier: AEAP_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEAP_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 885 No. of bytes in distributed program, including test data, etc.: 5925 Distribution format: tar.gz Programming language: Scilab 3.1.1 Computer: PC-compatible running Scilab on MS Windows or Linux Operating system: Windows XP, Linux RAM: below 100 Megabytes Classification: 6.2 Nature of problem: Any physical model containing linear or nonlinear ordinary differential equations (ODE). Solution method: Numerical solving of ordinary differential equations. The chaotic behavior of the nonlinear dynamical system is analyzed using Poincaré sections, phase-space maps, autocorrelation functions, power spectra, Lyapunov exponents and Kolmogorov-Sinai entropies. Restrictions: The package routines are normally able to handle ODE systems of high orders (up to order twelve and possibly higher), depending on the nature of the problem. Running time: 10 to 20 seconds for problems that do not

  4. Radiative transfer through terrestrial atmosphere and ocean: Software package SCIATRAN

    International Nuclear Information System (INIS)

    Rozanov, V.V.; Rozanov, A.V.; Kokhanovsky, A.A.; Burrows, J.P.

    2014-01-01

    SCIATRAN is a comprehensive software package for the modeling of radiative transfer processes in the terrestrial atmosphere and ocean in the spectral range from the ultraviolet to the thermal infrared (0.18–40μm) including multiple scattering processes, polarization, thermal emission and ocean–atmosphere coupling. The software is capable of modeling spectral and angular distributions of the intensity or the Stokes vector of the transmitted, scattered, reflected, and emitted radiation assuming either a plane-parallel or a spherical atmosphere. Simulations are done either in the scalar or in the vector mode (i.e. accounting for the polarization) for observations by space-, air-, ship- and balloon-borne, ground-based, and underwater instruments in various viewing geometries (nadir, off-nadir, limb, occultation, zenith-sky, off-axis). All significant radiative transfer processes are accounted for. These are, e.g. the Rayleigh scattering, scattering by aerosol and cloud particles, absorption by gaseous components, and bidirectional reflection by an underlying surface including Fresnel reflection from a flat or roughened ocean surface. The software package contains several radiative transfer solvers including finite difference and discrete-ordinate techniques, an extensive database, and a specific module for solving inverse problems. In contrast to many other radiative transfer codes, SCIATRAN incorporates an efficient approach to calculate the so-called Jacobians, i.e. derivatives of the intensity with respect to various atmospheric and surface parameters. In this paper we discuss numerical methods used in SCIATRAN to solve the scalar and vector radiative transfer equation, describe databases of atmospheric, oceanic, and surface parameters incorporated in SCIATRAN, and demonstrate how to solve some selected radiative transfer problems using the SCIATRAN package. During the last decades, a lot of studies have been published demonstrating that SCIATRAN is a valuable

  5. Software Packages to Support Electrical Engineering Virtual Lab

    Directory of Open Access Journals (Sweden)

    Manuel Travassos Valdez

    2012-03-01

    Full Text Available The use of Virtual Reality Systems (VRS, as a learning aid, encourages the creation of tools that allow users/students to simulate educational environments on a computer. This article presents a way of building a VRS system with Software Packages to support Electrical Engineering Virtual Laboratories to be used in a near future in the teaching of the curriculum unit of Circuit Theory. The steps required for the construction of a project are presented in this paper. The simulation is still under construction and intends to use a three-dimensional virtual environment laboratory electric measurement, which will allow users/students to experiment and test the modeled equipment. Therefore, there are still no links available for further examination. The result may demonstrate the future potential of applications of Virtual Reality Systems as an efficient and cost-effective learning system.

  6. Lenstronomy: Multi-purpose gravitational lens modeling software package

    Science.gov (United States)

    Birrer, Simon; Amara, Adam

    2018-04-01

    Lenstronomy is a multi-purpose open-source gravitational lens modeling python package. Lenstronomy reconstructs the lens mass and surface brightness distributions of strong lensing systems using forward modelling and supports a wide range of analytic lens and light models in arbitrary combination. The software is also able to reconstruct complex extended sources as well as point sources. Lenstronomy is flexible and numerically accurate, with a clear user interface that could be deployed across different platforms. Lenstronomy has been used to derive constraints on dark matter properties in strong lenses, measure the expansion history of the universe with time-delay cosmography, measure cosmic shear with Einstein rings, and decompose quasar and host galaxy light.

  7. Nonlinear analysis of reinforced concrete structures using software package abaqus

    Directory of Open Access Journals (Sweden)

    Marković Nemanja

    2014-01-01

    Full Text Available Reinforced concrete (AB is characterized by huge inhomogeneity resulting from the material characteristics of the concrete, then, quasi-brittle behavior during failure. These and other phenomena require the introduction of material nonlinearity in the modeling of reinforced concrete structures. This paper presents the modeling reinforced concrete in the software package ABAQUS. A brief theoretical overview is presented of methods such as: Concrete Damage Plasticity (CDP, Smeared Concrete Cracking (CSC, Cap Plasticity (CP and Drucker-Prager model (DPM. We performed a nonlinear analysis of two-storey reinforced concrete frame by applying CDP method for modeling material nonlinearity of concrete. We have analyzed damage zones, crack propagation and loading-deflection ratio.

  8. Evaluation and selection of open-source EMR software packages based on integrated AHP and TOPSIS.

    Science.gov (United States)

    Zaidan, A A; Zaidan, B B; Al-Haiqi, Ahmed; Kiah, M L M; Hussain, Muzammil; Abdulnabi, Mohamed

    2015-02-01

    Evaluating and selecting software packages that meet the requirements of an organization are difficult aspects of software engineering process. Selecting the wrong open-source EMR software package can be costly and may adversely affect business processes and functioning of the organization. This study aims to evaluate and select open-source EMR software packages based on multi-criteria decision-making. A hands-on study was performed and a set of open-source EMR software packages were implemented locally on separate virtual machines to examine the systems more closely. Several measures as evaluation basis were specified, and the systems were selected based a set of metric outcomes using Integrated Analytic Hierarchy Process (AHP) and TOPSIS. The experimental results showed that GNUmed and OpenEMR software can provide better basis on ranking score records than other open-source EMR software packages. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. gr-MRI: A software package for magnetic resonance imaging using software defined radios

    Science.gov (United States)

    Hasselwander, Christopher J.; Cao, Zhipeng; Grissom, William A.

    2016-09-01

    The goal of this work is to develop software that enables the rapid implementation of custom MRI spectrometers using commercially-available software defined radios (SDRs). The developed gr-MRI software package comprises a set of Python scripts, flowgraphs, and signal generation and recording blocks for GNU Radio, an open-source SDR software package that is widely used in communications research. gr-MRI implements basic event sequencing functionality, and tools for system calibrations, multi-radio synchronization, and MR signal processing and image reconstruction. It includes four pulse sequences: a single-pulse sequence to record free induction signals, a gradient-recalled echo imaging sequence, a spin echo imaging sequence, and an inversion recovery spin echo imaging sequence. The sequences were used to perform phantom imaging scans with a 0.5 Tesla tabletop MRI scanner and two commercially-available SDRs. One SDR was used for RF excitation and reception, and the other for gradient pulse generation. The total SDR hardware cost was approximately 2000. The frequency of radio desynchronization events and the frequency with which the software recovered from those events was also measured, and the SDR's ability to generate frequency-swept RF waveforms was validated and compared to the scanner's commercial spectrometer. The spin echo images geometrically matched those acquired using the commercial spectrometer, with no unexpected distortions. Desynchronization events were more likely to occur at the very beginning of an imaging scan, but were nearly eliminated if the user invoked the sequence for a short period before beginning data recording. The SDR produced a 500 kHz bandwidth frequency-swept pulse with high fidelity, while the commercial spectrometer produced a waveform with large frequency spike errors. In conclusion, the developed gr-MRI software can be used to develop high-fidelity, low-cost custom MRI spectrometers using commercially-available SDRs.

  10. Software refactoring at the package level using clustering techniques

    KAUST Repository

    Alkhalid, A.; Alshayeb, M.; Mahmoud, S. A.

    2011-01-01

    Enhancing, modifying or adapting the software to new requirements increases the internal software complexity. Software with high level of internal complexity is difficult to maintain. Software refactoring reduces software complexity and hence

  11. Development of an engine system simulation software package - ESIM

    Energy Technology Data Exchange (ETDEWEB)

    Erlandsson, Olof

    2000-10-01

    A software package, ESIM is developed for simulating internal combustion engine systems, including models for engine, manifolds, turbocharger, charge-air cooler (inter cooler) and inlet air heater. This study focus on the thermodynamic treatment and methods used in the models. It also includes some examples of system simulations made with these models for validation purposes. The engine model can be classified as a zero-dimensional, single zone model. It includes calculation of the valve flow process, models for heat release and models for in-cylinder, exhaust port and manifold heat transfer. Models are developed for handling turbocharger performance and charge air cooler characteristics. The main purpose of the project related to this work is to use the ESIM software to study heat balance and performance of homogeneous charge compression ignition (HCCI) engine systems. A short description of the HCCI engine is therefore included, pointing out the difficulties, or challenges regarding the HCCI engine, from a system perspective. However, the relations given here, and the code itself, is quite general, making it possible to use these models to simulate spark ignited, as well as direct injected engines.

  12. Motofit - integrating neutron reflectometry acquisition, reduction and analysis into one, easy to use, package

    International Nuclear Information System (INIS)

    Nelson, Andrew

    2010-01-01

    The efficient use of complex neutron scattering instruments is often hindered by the complex nature of their operating software. This complexity exists at each experimental step: data acquisition, reduction and analysis, with each step being as important as the previous. For example, whilst command line interfaces are powerful at automated acquisition they often reduce accessibility by novice users and sometimes reduce the efficiency for advanced users. One solution to this is the development of a graphical user interface which allows the user to operate the instrument by a simple and intuitive 'push button' approach. This approach was taken by the Motofit software package for analysis of multiple contrast reflectometry data. Here we describe the extension of this package to cover the data acquisition and reduction steps for the Platypus time-of-flight neutron reflectometer. Consequently, the complete operation of an instrument is integrated into a single, easy to use, program, leading to efficient instrument usage.

  13. UES: an optimization software package for power and energy

    International Nuclear Information System (INIS)

    Vohryzek, J.; Havlena, V.; Findejs, J.; Jech, J.

    2004-01-01

    Unified Energy Solutions components are designed to meet specific requirements of the electric utilities, industrial power units, and district heating (combined heat and power) plants. The optimization objective is to operate the plant with maximum process efficiency and operational profit under the constraints imposed by technology and environmental impacts. Software applications for advanced control real-time optimization may provide a low-cost, high return alternative to expensive boiler retrofits for improving operational profit as well as reducing emissions. Unified Energy Solutions (UES) software package is a portfolio of advanced control and optimization components running on top of the standard process regulatory and control system. The objective of the UES is to operate the plant with maximum achievable profit (maximum efficiency) under the constraints imposed by technology (life-time consumption, asset health) and environmental impacts (CO and NO x emissions). Fast responsiveness to varying economic conditions and integration of real-time optimization and operator decision support (off-line) features are critical for operation in real-time economy. Optimization Features are targeted to combustion process, heat and power load allocation to parallel resources, electric power delivery and ancillary services. Optimization Criteria include increased boiler thermal efficiency, maintaining emission limits, economic load allocation of the heat and generation sources. State-of-the-art advanced control algorithms use model based predictive control principles and provide superior response in transient states. Individual software modules support open control platforms and communication protocols. UES can be implemented on a wide range of distributed control systems. Typical achievable benefits include heat and power production costs savings, increased effective boiler operation range, optimized flue gas emissions, optimized production capacity utilization, optimized

  14. Information technologies and software packages for education of specialists in materials science [In Russian

    NARCIS (Netherlands)

    Krzhizhanovskaya, V.; Ryaboshuk, S.

    2009-01-01

    This paper presents methodological materials, interactive text-books and software packages developed and extensively used for education of specialists in materials science. These virtual laboratories for education and research are equipped with tutorials and software environment for modeling complex

  15. Data Reduction and Control Software for Meteor Observing Stations Based on CCD Video Systems

    Science.gov (United States)

    Madiedo, J. M.; Trigo-Rodriguez, J. M.; Lyytinen, E.

    2011-01-01

    The SPanish Meteor Network (SPMN) is performing a continuous monitoring of meteor activity over Spain and neighbouring countries. The huge amount of data obtained by the 25 video observing stations that this network is currently operating made it necessary to develop new software packages to accomplish some tasks, such as data reduction and remote operation of autonomous systems based on high-sensitivity CCD video devices. The main characteristics of this software are described here.

  16. Strategic Business-IT alignment of application software packages: Bridging the Information Technology gap

    Directory of Open Access Journals (Sweden)

    Wandi Kruger

    2012-09-01

    Full Text Available An application software package implementation is a complex endeavour, and as such it requires the proper understanding, evaluation and redefining of the current business processes to ensure that the implementation delivers on the objectives set at the start of the project. Numerous factors exist that may contribute to the unsuccessful implementation of application software packages. However, the most significant contributor to the failure of an application software package implementation lies in the misalignment of the organisation’s business processes with the functionality of the application software package. Misalignment is attributed to a gap that exists between the business processes of an organisation and what functionality the application software package has to offer to translate the business processes of an organisation into digital form when implementing and configuring an application software package. This gap is commonly referred to as the information technology (IT gap. This study proposes to define and discuss the IT gap. Furthermore this study will make recommendations for aligning the business processes with the functionality of the application software package (addressing the IT gap. The end result of adopting these recommendations will be more successful application software package implementations.

  17. IDES: Interactive Data Entry System: a generalized data acquisition software package

    International Nuclear Information System (INIS)

    Gasser, S.B.

    1980-04-01

    The Interactive Data Entry System (IDES) is a software package which greatly assists in designing and storing forms to be used for the directed acquisition of data. Objective of this package is to provide a viable man/machine interface to any comprehensive data base. This report provides a technical description of the software and can be used as a user's manual

  18. US Army Radiological Bioassay and Dosimetry: The RBD software package

    International Nuclear Information System (INIS)

    Eckerman, K.F.; Ward, R.C.; Maddox, L.B.

    1993-01-01

    The RBD (Radiological Bioassay and Dosimetry) software package was developed for the U. S. Army Material Command, Arlington, Virginia, to demonstrate compliance with the radiation protection guidance 10 CFR Part 20 (ref. 1). Designed to be run interactively on an IBM-compatible personal computer, RBD consists of a data base module to manage bioassay data and a computational module that incorporates algorithms for estimating radionuclide intake from either acute or chronic exposures based on measurement of the worker's rate of excretion of the radionuclide or the retained activity in the body. In estimating the intake,RBD uses a separate file for each radionuclide containing parametric representations of the retention and excretion functions. These files also contain dose-per-unit-intake coefficients used to compute the committed dose equivalent. For a given nuclide, if measurements exist for more than one type of assay, an auxiliary module, REPORT, estimates the intake by applying weights assigned in the nuclide file for each assay. Bioassay data and computed results (estimates of intake and committed dose equivalent) are stored in separate data bases, and the bioassay measurements used to compute a given result can be identified. The REPORT module creates a file containing committed effective dose equivalent for each individual that can be combined with the individual's external exposure

  19. Nanotechnology for the Solid Waste Reduction of Military Food Packaging

    Science.gov (United States)

    2016-06-01

    WP-200816) Nanotechnology for the Solid Waste Reduction of Military Food Packaging June 2016 This document has been cleared for public release...NAME OF RESPONSIBLE PERSON 19b. TELEPHONE NUMBER (Include area code) 01/06/2016 Cost and Performance Report 04/01/2008 - 01/01/2015 Nanotechnology for...Soldier Research, Development and Engineering Center Robin Altmeyer - AmeriQual U.S. Army Natick Soldier Research, Development and Engineering

  20. Closing the loop on improvement: Packaging experience in the Software Engineering Laboratory

    Science.gov (United States)

    Waligora, Sharon R.; Landis, Linda C.; Doland, Jerry T.

    1994-01-01

    As part of its award-winning software process improvement program, the Software Engineering Laboratory (SEL) has developed an effective method for packaging organizational best practices based on real project experience into useful handbooks and training courses. This paper shares the SEL's experience over the past 12 years creating and updating software process handbooks and training courses. It provides cost models and guidelines for successful experience packaging derived from SEL experience.

  1. Software and package applicating for network meta-analysis: A usage-based comparative study.

    Science.gov (United States)

    Xu, Chang; Niu, Yuming; Wu, Junyi; Gu, Huiyun; Zhang, Chao

    2017-12-21

    To compare and analyze the characteristics and functions of software applications for network meta-analysis (NMA). PubMed, EMbase, The Cochrane Library, the official websites of Bayesian inference Using Gibbs Sampling (BUGS), Stata and R, and Google were searched to collect the software and packages for performing NMA; software and packages published up to March 2016 were included. After collecting the software, packages, and their user guides, we used the software and packages to calculate a typical example. All characteristics, functions, and computed results were compared and analyzed. Ten types of software were included, including programming and non-programming software. They were developed mainly based on Bayesian or frequentist theory. Most types of software have the characteristics of easy operation, easy mastery, exact calculation, or excellent graphing. However, there was no single software that performed accurate calculations with superior graphing; this could only be achieved through the combination of two or more types of software. This study suggests that the user should choose the appropriate software according to personal programming basis, operational habits, and financial ability. Then, the choice of the combination of BUGS and R (or Stata) software to perform the NMA is considered. © 2017 Chinese Cochrane Center, West China Hospital of Sichuan University and John Wiley & Sons Australia, Ltd.

  2. Incubator Display Software Cost Reduction Toolset Software Requirements Specification

    Science.gov (United States)

    Moran, Susanne; Jeffords, Ralph

    2005-01-01

    The Incubator Display Software Requirements Specification was initially developed by Intrinsyx Technologies Corporation (Intrinsyx) under subcontract to Lockheed Martin, Contract Number NAS2-02090, for the National Aeronautics and Space Administration (NASA) Ames Research Center (ARC) Space Station Biological Research Project (SSBRP). The Incubator Display is a User Payload Application (UPA) used to control an Incubator subrack payload for the SSBRP. The Incubator Display functions on-orbit as part of the subrack payload laptop, on the ground as part of the Communication and Data System (CDS) ground control system, and also as part of the crew training environment.

  3. Deriving stellar parameters with the SME software package

    Science.gov (United States)

    Piskunov, N.

    2017-09-01

    Photometry and spectroscopy are complementary tools for deriving accurate stellar parameters. Here I present one of the popular packages for stellar spectroscopy called SME with the emphasis on the latest developments and error assessment for the derived parameters.

  4. Using packaged software for solving two differential equation problems that arise in plasma physics

    International Nuclear Information System (INIS)

    Gaffney, P.W.

    1980-01-01

    Experience in using packaged numerical software for solving two related problems that arise in Plasma physics is described. These problems are (i) the solution of the reduced resistive MHD equations and (ii) the solution of the Grad-Shafranov equation

  5. Development of a new control software package for Pakistan Research Reactor-2

    International Nuclear Information System (INIS)

    Qazi, M.K.

    1993-05-01

    The development of a new control software package for Pakistan Research Reactor-2 is presented. The software operates in different modes which comprises of surveillance, pre-operational self tests, operator, supervisor and robotic control. The control logic critically damp the system minimizing power overshoots. The software, handles multiple abnormal conditions, provides an elaborate access control and maintains startup/shutdown record. The report describes the functional details and covers the operational aspects of the new control software. (author)

  6. Computer aided piping layout design in radiochemical plants- an improved software package

    International Nuclear Information System (INIS)

    Raju, R.P.; Siddiqui, H.R.

    1995-01-01

    A software package was developed and it was successfully implemented for the piping layout design of the four process cells of the Kalpakkam Reprocessing Project. This paper discusses in detail all the improvements and modifications that are being carried out in the package so that it becomes more meaningful and useful for implementation for the forthcoming radiochemical plants

  7. Western aeronautical test range real-time graphics software package MAGIC

    Science.gov (United States)

    Malone, Jacqueline C.; Moore, Archie L.

    1988-01-01

    The master graphics interactive console (MAGIC) software package used on the Western Aeronautical Test Range (WATR) of the NASA Ames Research Center is described. MAGIC is a resident real-time research tool available to flight researchers-scientists in the NASA mission control centers of the WATR at the Dryden Flight Research Facility at Edwards, California. The hardware configuration and capabilities of the real-time software package are also discussed.

  8. User's manual for the UNDERDOG [Underground Nuclear Depository Evaluation, Reduction, and Detailed Output Generator] data reduction software

    International Nuclear Information System (INIS)

    Ball, J.R.; Shepard, L.K.

    1987-12-01

    UNDERDOG is a computer program that aids experimentalists in the process of data reduction. This software allows a user to reduce, extract, and generate displays of data collected at the WIPP site. UNDERDOG contains three major functional components: a Data Reduction package, a Data Analysis interface, and a Publication-Quality Output generator. It also maintains audit trails of all actions performed for quality assurance purposes and provides mechanisms which control an individual's access to the data. UNDERDOG was designed to run on a Digital Equipment Corporation VAX computer using the VMS operating system. 8 refs., 24 figs., 2 tabs

  9. Risk Analysis and Decision-Making Software Package (1997 Version) User Manual

    Energy Technology Data Exchange (ETDEWEB)

    Chung, F.T.H.

    1999-02-11

    This manual provides instructions for using the U.S. Department of Energy's (DOE) risk analysis and decision making software (1997 version) developed at BDM Petroleum Technologies by BDM-Oklahoma, Inc. for DOE, under contract No. DE-AC22-94PC91OO8. This software provides petroleum producers with a simple, handy tool for exploration and production risk analysis and decision-making. It collects useful risk analysis tools in one package so that users do not have to use several programs separately. The software is simple to use, but still provides many functions. The 1997 version of the software package includes the following tools: (1) Investment risk (Gambler's ruin) analysis; (2) Monte Carlo simulation; (3) Best fit for distribution functions; (4) Sample and rank correlation; (5) Enhanced oil recovery method screening; and (6) artificial neural network. This software package is subject to change. Suggestions and comments from users are welcome and will be considered for future modifications and enhancements of the software. Please check the opening screen of the software for the current contact information. In the future, more tools will be added to this software package. This manual includes instructions on how to use the software but does not attempt to fully explain the theory and algorithms used to create it.

  10. QuantWorm: a comprehensive software package for Caenorhabditis elegans phenotypic assays.

    Directory of Open Access Journals (Sweden)

    Sang-Kyu Jung

    Full Text Available Phenotypic assays are crucial in genetics; however, traditional methods that rely on human observation are unsuitable for quantitative, large-scale experiments. Furthermore, there is an increasing need for comprehensive analyses of multiple phenotypes to provide multidimensional information. Here we developed an automated, high-throughput computer imaging system for quantifying multiple Caenorhabditis elegans phenotypes. Our imaging system is composed of a microscope equipped with a digital camera and a motorized stage connected to a computer running the QuantWorm software package. Currently, the software package contains one data acquisition module and four image analysis programs: WormLifespan, WormLocomotion, WormLength, and WormEgg. The data acquisition module collects images and videos. The WormLifespan software counts the number of moving worms by using two time-lapse images; the WormLocomotion software computes the velocity of moving worms; the WormLength software measures worm body size; and the WormEgg software counts the number of eggs. To evaluate the performance of our software, we compared the results of our software with manual measurements. We then demonstrated the application of the QuantWorm software in a drug assay and a genetic assay. Overall, the QuantWorm software provided accurate measurements at a high speed. Software source code, executable programs, and sample images are available at www.quantworm.org. Our software package has several advantages over current imaging systems for C. elegans. It is an all-in-one package for quantifying multiple phenotypes. The QuantWorm software is written in Java and its source code is freely available, so it does not require use of commercial software or libraries. It can be run on multiple platforms and easily customized to cope with new methods and requirements.

  11. The paradox of packaging optimization – a characterization of packaging source reduction in the Netherlands

    NARCIS (Netherlands)

    van Sluisveld, M.A.E.; Worrell, E.

    2013-01-01

    The European Council Directive 94/62/EC for Packaging and Packaging Waste requires that Member States implement packaging waste prevention measures. However, consumption and subsequently packaging waste figures are still growing annually. It suggests that policies to accomplish packaging waste

  12. Effective organizational solutions for implementation of DBMS software packages

    Science.gov (United States)

    Jones, D.

    1984-01-01

    The space telescope management information system development effort is a guideline for discussing effective organizational solutions used in implementing DBMS software. Focus is on the importance of strategic planning. The value of constructing an information system architecture to conform to the organization's managerial needs, the need for a senior decision maker, dealing with shifting user requirements, and the establishment of a reliable working relationship with the DBMS vendor are examined. Requirements for a schedule to demonstrate progress against a defined timeline and the importance of continued monitoring for production software control, production data control, and software enhancements are also discussed.

  13. Learn by Yourself: The Self-Learning Tools for Qualitative Analysis Software Packages

    Science.gov (United States)

    Freitas, Fábio; Ribeiro, Jaime; Brandão, Catarina; Reis, Luís Paulo; de Souza, Francislê Neri; Costa, António Pedro

    2017-01-01

    Computer Assisted Qualitative Data Analysis Software (CAQDAS) are tools that help researchers to develop qualitative research projects. These software packages help the users with tasks such as transcription analysis, coding and text interpretation, writing and annotation, content search and analysis, recursive abstraction, grounded theory…

  14. QuickDirect - Payload Control Software Template Package, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — To address the need to quickly, cost-effectively and reliably develop software to control science instruments deployed on spacecraft, QuickFlex proposes to create a...

  15. BEANS - a software package for distributed Big Data analysis

    Science.gov (United States)

    Hypki, Arkadiusz

    2018-03-01

    BEANS software is a web based, easy to install and maintain, new tool to store and analyse in a distributed way a massive amount of data. It provides a clear interface for querying, filtering, aggregating, and plotting data from an arbitrary number of datasets. Its main purpose is to simplify the process of storing, examining and finding new relations in huge datasets. The software is an answer to a growing need of the astronomical community to have a versatile tool to store, analyse and compare the complex astrophysical numerical simulations with observations (e.g. simulations of the Galaxy or star clusters with the Gaia archive). However, this software was built in a general form and it is ready to use in any other research field. It can be used as a building block for other open source software too.

  16. Creating a simulation model of software testing using Simulink package

    Directory of Open Access Journals (Sweden)

    V. M. Dubovoi

    2016-12-01

    Full Text Available The determination of the solution model of software testing that allows prediction both the whole process and its specific stages is actual for IT-industry. The article focuses on solving this problem. The aim of the article is prediction the time and improvement the quality of software testing. The analysis of the software testing process shows that it can be attributed to the branched cyclic technological processes because it is cyclical with decision-making on control operations. The investigation uses authors' previous works andsoftware testing process method based on Markov model. The proposed method enables execution the prediction for each software module, which leads to better decision-making of each controlled suboperation of all processes. Simulink simulation model shows implementation and verification of results of proposed technique. Results of the research have practically implemented in the IT-industry.

  17. Investigating the effects of different factors on development of open source enterprise resources planning software packages

    Directory of Open Access Journals (Sweden)

    Mehdi Ghorbaninia

    2014-08-01

    Full Text Available This paper investigates the effects of different factors on development of open source enterprise resources planning software packages. The study designs a questionnaire in Likert scale and distributes it among 210 experts in the field of open source software package development. Cronbach alpha has been calculated as 0.93, which is well above the minimum acceptable level. Using Pearson correlation as well as stepwise regression analysis, the study determines three most important factors including fundamental issues, during and after implementation of open source software development. The study also determines a positive and strong relationship between fundamental factors and after implementation factors (r=0.9006, Sig. = 0.000.

  18. An Ada Linear-Algebra Software Package Modeled After HAL/S

    Science.gov (United States)

    Klumpp, Allan R.; Lawson, Charles L.

    1990-01-01

    New avionics software written more easily. Software package extends Ada programming language to include linear-algebra capabilities similar to those of HAL/S programming language. Designed for such avionics applications as Space Station flight software. In addition to built-in functions of HAL/S, package incorporates quaternion functions used in Space Shuttle and Galileo projects and routines from LINPAK solving systems of equations involving general square matrices. Contains two generic programs: one for floating-point computations and one for integer computations. Written on IBM/AT personal computer running under PC DOS, v.3.1.

  19. SIMODIS - a software package for simulating nuclear reactor components

    International Nuclear Information System (INIS)

    Guimaraes, Lamartine; Borges, Eduardo M.

    2000-01-01

    In this paper it is presented the initial development effort in building a nuclear reactor component simulation package. This package was developed to be used in the MATLAB simulation environment. It uses the graphical capabilities from MATLAB and the advantages of compiled languages, as for instance FORTRAN and C ++ . From the MATLAB it takes the facilities for better displaying the calculated results. From the compiled languages it takes processing speed. So far models from reactor core, UTSG and OTSG have been developed. Also, a series a user-friendly graphical interfaces have been developed for the above models. As a by product a set of water and sodium thermal and physical properties have been developed and may be used directly as a function from MATLAB, or by being called from a model, as part of its calculation process. The whole set was named SIMODIS, which stands for SIstema MODular Integrado de Simulacao. (author)

  20. The quality and testing PH-SFT infrastructure for the external LHC software packages deployment

    CERN Multimedia

    CERN. Geneva; MENDEZ LORENZO, Patricia; MATO VILA, Pere

    2015-01-01

    The PH-SFT group is responsible for the build, test, and deployment of the set of external software packages used by the LHC experiments. This set includes ca. 170 packages including Grid packages and Montecarlo generators provided for different versions. A complete build structure has been established to guarantee the quality of the packages provided by the group. This structure includes an experimental build and three daily nightly builds, each of them dedicated to a specific ROOT version including v6.02, v6.04, and the master. While the former build is dedicated to the test of new packages, versions and dependencies (basically SFT internal used), the three latter ones are the responsible for the deployment to AFS of the set of stable and well tested packages requested by the LHC experiments so they can apply their own builds on top. In all cases, a c...

  1. ZE3RA: the ZEPLIN-III Reduction and Analysis package

    International Nuclear Information System (INIS)

    Neves, F; Chepel, V; DeViveiros, L; Lindote, A; Lopes, M I; Akimov, D Yu; Belov, V A; Burenkov, A A; Kobyakin, A S; Kovalenko, A G; Araújo, H M; Currie, A; Horn, M; Lebedenko, V N; Barnes, E J; Ghag, C; Hollingsworth, A; Edwards, B; Kalmus, G E; Lüscher, R

    2011-01-01

    ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the detection of scintillation pulses down to a single photoelectron and of ionisation signals as small as those produced by single electrons. We discuss in particular several strategies related to data filtering, pulse finding and pulse clustering which are tuned using calibration data to recover the best electron/nuclear recoil discrimination near the detection threshold, where most dark matter elastic scattering signatures are expected. The software was designed assuming only minimal knowledge of the physics underlying the detection principle, allowing an unbiased analysis of the experimental results and easy extension to other detectors with similar requirements.

  2. A process control software package for the SRS

    International Nuclear Information System (INIS)

    Atkins, V.R.; Poole, D.E.; Rawlinson, W.R.

    1980-03-01

    The development of software to give high level access from application programs for monitoring and control of the Daresbury Synchrotron Radiation Source on a network-wide basis is described. The design and implementation of the control system database, a special supervisor call and and 'executive' type task handling of all process input/output services for the 7/32 (which runs under 05/32-MT), and process control 'device driver' software for the 7/16 (run under L5/16-MT) are included. (UK)

  3. The Supertree Toolkit 2: a new and improved software package with a Graphical User Interface for supertree construction

    Directory of Open Access Journals (Sweden)

    Jon Hill

    2014-03-01

    Full Text Available Building large supertrees involves the collection, storage, and processing of thousands of individual phylogenies to create large phylogenies with thousands to tens of thousands of taxa. Such large phylogenies are useful for macroevolutionary studies, comparative biology and in conservation and biodiversity. No easy to use and fully integrated software package currently exists to carry out this task. Here, we present a new Python-based software package that uses well defined XML schema to manage both data and metadata. It builds on previous versions by 1 including new processing steps, such as Safe Taxonomic Reduction, 2 using a user-friendly GUI that guides the user to complete at least the minimum information required and includes context-sensitive documentation, and 3 a revised storage format that integrates both tree- and meta-data into a single file. These data can then be manipulated according to a well-defined, but flexible, processing pipeline using either the GUI or a command-line based tool. Processing steps include standardising names, deleting or replacing taxa, ensuring adequate taxonomic overlap, ensuring data independence, and safe taxonomic reduction. This software has been successfully used to store and process data consisting of over 1000 trees ready for analyses using standard supertree methods. This software makes large supertree creation a much easier task and provides far greater flexibility for further work.

  4. The Supertree Toolkit 2: a new and improved software package with a Graphical User Interface for supertree construction.

    Science.gov (United States)

    Hill, Jon; Davis, Katie E

    2014-01-01

    Building large supertrees involves the collection, storage, and processing of thousands of individual phylogenies to create large phylogenies with thousands to tens of thousands of taxa. Such large phylogenies are useful for macroevolutionary studies, comparative biology and in conservation and biodiversity. No easy to use and fully integrated software package currently exists to carry out this task. Here, we present a new Python-based software package that uses well defined XML schema to manage both data and metadata. It builds on previous versions by 1) including new processing steps, such as Safe Taxonomic Reduction, 2) using a user-friendly GUI that guides the user to complete at least the minimum information required and includes context-sensitive documentation, and 3) a revised storage format that integrates both tree- and meta-data into a single file. These data can then be manipulated according to a well-defined, but flexible, processing pipeline using either the GUI or a command-line based tool. Processing steps include standardising names, deleting or replacing taxa, ensuring adequate taxonomic overlap, ensuring data independence, and safe taxonomic reduction. This software has been successfully used to store and process data consisting of over 1000 trees ready for analyses using standard supertree methods. This software makes large supertree creation a much easier task and provides far greater flexibility for further work.

  5. Evaluation of open source data mining software packages

    Science.gov (United States)

    Bonnie Ruefenacht; Greg Liknes; Andrew J. Lister; Haans Fisk; Dan Wendt

    2009-01-01

    Since 2001, the USDA Forest Service (USFS) has used classification and regression-tree technology to map USFS Forest Inventory and Analysis (FIA) biomass, forest type, forest type groups, and National Forest vegetation. This prior work used Cubist/See5 software for the analyses. The objective of this project, sponsored by the Remote Sensing Steering Committee (RSSC),...

  6. A Relative Comparison of Leading Supply Chain Management Software Packages

    OpenAIRE

    Zhongxian Wang; Ruiliang Yan; Kimberly Hollister; Ruben Xing

    2009-01-01

    Supply Chain Management (SCM) has proven to be an effective tool that aids companies in the development of competitive advantages. SCM Systems are relied on to manage warehouses, transportation, trade logistics and various other issues concerning the coordinated movement of products and services from suppliers to customers. Although in today’s fast paced business environment, numerous supply chain solution tools are readily available to companies, choosing the right SCM software is not an e...

  7. PALSfit3: A software package for analysing positron lifetime spectra

    DEFF Research Database (Denmark)

    Kirkegaard, Peter; Olsen, Jens V.; Eldrup, Morten Mostgaard

    The present report describes a Windows based computer program called PALSfit3. The purpose of the program is to carry out analyses of spectra that have been measured by positron annihilation lifetime spectroscopy (PALS). PALSfit3 is based on the well tested PATFIT and PALS fit programs, which hav...... in a text window. PALSfit3 is verified on Windows XP and Windows 7, 8 and 10. The PALSfit3 software can be acquired from the Technical University of Denmark (http://PALSfit.dk)...

  8. InterFace: A software package for face image warping, averaging, and principal components analysis.

    Science.gov (United States)

    Kramer, Robin S S; Jenkins, Rob; Burton, A Mike

    2017-12-01

    We describe InterFace, a software package for research in face recognition. The package supports image warping, reshaping, averaging of multiple face images, and morphing between faces. It also supports principal components analysis (PCA) of face images, along with tools for exploring the "face space" produced by PCA. The package uses a simple graphical user interface, allowing users to perform these sophisticated image manipulations without any need for programming knowledge. The program is available for download in the form of an app, which requires that users also have access to the (freely available) MATLAB Runtime environment.

  9. Maximize Your Investment 10 Key Strategies for Effective Packaged Software Implementations

    CERN Document Server

    Beaubouef, Grady Brett

    2009-01-01

    This is a handbook covering ten principles for packaged software implementations that project managers, business owners, and IT developers should pay attention to. The book also has practical real-world coverage including a sample agenda for conducting business solution modeling, customer case studies, and a road map to implement guiding principles. This book is aimed at enterprise architects, development leads, project managers, business systems analysts, business systems owners, and anyone who wants to implement packaged software effectively. If you are a customer looking to implement COTS s

  10. Development of 'Enhance reconstruction package' software for whole-body PET

    International Nuclear Information System (INIS)

    Mizuta, Tetsuro; Imanishi, Tatsuru; Ishikawa, Akihiro

    2011-01-01

    We have developed 'Enhance Reconstruction Package' Software for our whole-body positron emission tomography (PET) Eminence series. This package improves image quality and streamlines the workflow in clinical PET and PET/CT studies. The present paper describes an outline of the applications for data collection, normalization, etc. and also reports some PET images obtained by the software. The signal to noise ratio was optimized in the phantom study, leading to the improvement in image quality. The real time display tool and the remote control tool would make a contribution to enhancement in operability in the routine workflow. (author)

  11. Vertical bone measurements from cone beam computed tomography images using different software packages

    Energy Technology Data Exchange (ETDEWEB)

    Vasconcelos, Taruska Ventorini; Neves, Frederico Sampaio; Moraes, Livia Almeida Bueno; Freitas, Deborah Queiroz, E-mail: tataventorini@hotmail.com [Universidade Estadual de Campinas (UNICAMP), Piracicaba, SP (Brazil). Faculdade de Odontologia

    2015-03-01

    This article aimed at comparing the accuracy of linear measurement tools of different commercial software packages. Eight fully edentulous dry mandibles were selected for this study. Incisor, canine, premolar, first molar and second molar regions were selected. Cone beam computed tomography (CBCT) images were obtained with i-CAT Next Generation. Linear bone measurements were performed by one observer on the cross-sectional images using three different software packages: XoranCat®, OnDemand3D® and KDIS3D®, all able to assess DICOM images. In addition, 25% of the sample was reevaluated for the purpose of reproducibility. The mandibles were sectioned to obtain the gold standard for each region. Intraclass coefficients (ICC) were calculated to examine the agreement between the two periods of evaluation; the one-way analysis of variance performed with the post-hoc Dunnett test was used to compare each of the software-derived measurements with the gold standard. The ICC values were excellent for all software packages. The least difference between the software-derived measurements and the gold standard was obtained with the OnDemand3D and KDIS3D (‑0.11 and ‑0.14 mm, respectively), and the greatest, with the XoranCAT (+0.25 mm). However, there was no statistical significant difference between the measurements obtained with the different software packages and the gold standard (p > 0.05). In conclusion, linear bone measurements were not influenced by the software package used to reconstruct the image from CBCT DICOM data. (author)

  12. Vertical bone measurements from cone beam computed tomography images using different software packages

    International Nuclear Information System (INIS)

    Vasconcelos, Taruska Ventorini; Neves, Frederico Sampaio; Moraes, Livia Almeida Bueno; Freitas, Deborah Queiroz

    2015-01-01

    This article aimed at comparing the accuracy of linear measurement tools of different commercial software packages. Eight fully edentulous dry mandibles were selected for this study. Incisor, canine, premolar, first molar and second molar regions were selected. Cone beam computed tomography (CBCT) images were obtained with i-CAT Next Generation. Linear bone measurements were performed by one observer on the cross-sectional images using three different software packages: XoranCat®, OnDemand3D® and KDIS3D®, all able to assess DICOM images. In addition, 25% of the sample was reevaluated for the purpose of reproducibility. The mandibles were sectioned to obtain the gold standard for each region. Intraclass coefficients (ICC) were calculated to examine the agreement between the two periods of evaluation; the one-way analysis of variance performed with the post-hoc Dunnett test was used to compare each of the software-derived measurements with the gold standard. The ICC values were excellent for all software packages. The least difference between the software-derived measurements and the gold standard was obtained with the OnDemand3D and KDIS3D (‑0.11 and ‑0.14 mm, respectively), and the greatest, with the XoranCAT (+0.25 mm). However, there was no statistical significant difference between the measurements obtained with the different software packages and the gold standard (p > 0.05). In conclusion, linear bone measurements were not influenced by the software package used to reconstruct the image from CBCT DICOM data. (author)

  13. Overview of the MCU Monte Carlo software package

    International Nuclear Information System (INIS)

    Kalugin, M.A.; Oleynik, D.S.; Shkarovsky, D.A.

    2013-01-01

    MCU (Monte Carlo Universal) is a project on development and practical use of a universal computer code for simulation of particle transport (neutrons, photons, electrons, positrons) in three-dimensional systems by means of the Monte Carlo method. This paper provides the information on the current state of the project. The developed libraries of constants are briefly described, and the potentialities of the MCU-5 package modules and the executable codes compiled from them are characterized. Examples of important problems of reactor physics solved with the code are presented. It is shown that the MCU constructor tool is able to assemble a full-scale 3D model from templates describing single components using simple and intuitive graphic user interface. The templates are prepared by a skilled user and stored in constructor's templates library. Ordinary user works with the graphic user interface and does not deal with MCU input data directly. At the present moment there are template libraries for several types of reactors

  14. In-field inspection support software: A status report on the Common Inspection On-site Software Package (CIOSP) project

    International Nuclear Information System (INIS)

    Novatchev, Dimitre; Titov, Pavel; Siradjov, Bakhtiiar; Vlad, Ioan; Xiao Jing

    2001-01-01

    Full text: IAEA has invested much thought and effort into developing software that can assist inspectors during their inspection work. Experience with such applications has been steadily growing and IAEA has recently commissioned a next-generation software package. This kind of software accommodates inspection tasks that can vary substantially in function depending on the type of installation being inspected as well as ensures that the resulting software package has a wide range of usability and can preclude excessive development of plant-specific applications. The Common Inspection On-site Software Package is being developed in the Department of Safeguards to address the limitations of the existing software and to expand its coverage of the inspection process. CIOSP is 'common' in that it is aimed at providing support for as many facilities as possible with the minimum re-configuration. At the same time it has to cater to varying needs of individual facilities, different instrumentation and verification methods used. A component-based approach was taken to successfully tackle the challenges that the development of this software presented. CIOSP consists of the following major components: A framework into which individual plug-ins supporting various inspection activities can integrate at run-time; A central data store containing all facility configuration data and all data collected during inspections; A local data store, which resides on the inspector's computer, where the current inspection's data is stored; A set of services used by all plug-ins (i.e. data transformation, authentication, replication services etc.). This architecture allows for incremental development and extension of the software with plug-ins that support individual inspection activities. The core set of components along with the framework, the Inventory Verification, Book Examination and Records and Reports Comparison plug-ins have been developed. The development of the Short Notice Random

  15. PyPedal, an open source software package for pedigree analysis

    Science.gov (United States)

    The open source software package PyPedal (http://pypedal.sourceforge.net/) was first released in 2002, and provided users with a set of simple tools for manipulating pedigrees. Its flexibility has been demonstrated by its used in a number of settings for large and small populations. After substantia...

  16. Comparison of four software packages for CT lung volumetry in healthy individuals

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Stefan F. [Harvard Medical School, Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA (United States); Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Molinari, Francesco [Centre Hospitalier Regional Universitaire de Lille, Department of Radiology, Lille (France); Dufresne, Valerie [CHU de Charleroi - Hopital Vesale, Pneumologie, Montigny-le-Tilleul (Belgium); Gosset, Natacha [CHU Tivoli, Service d' Imagerie Medicale, La Louviere (Belgium); Silva, Mario; Bankier, Alexander A. [Harvard Medical School, Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA (United States)

    2015-06-01

    To compare CT lung volumetry (CTLV) measurements provided by different software packages, and to provide normative data for lung densitometric measurements in healthy individuals. This retrospective study included 51 chest CTs of 17 volunteers (eight men and nine women; mean age, 30 ± 6 years), who underwent spirometrically monitored CT at total lung capacity (TLC), functional residual capacity (FRC), and mean inspiratory capacity (MIC). Volumetric differences assessed by four commercial software packages were compared with analysis of variance (ANOVA) for repeated measurements and benchmarked against the threshold for acceptable variability between spirometric measurements. Mean lung density (MLD) and parenchymal heterogeneity (MLD-SD) were also compared with ANOVA. Volumetric differences ranged from 12 to 213 ml (0.20 % to 6.45 %). Although 16/18 comparisons (among four software packages at TLC, MIC, and FRC) were statistically significant (P < 0.001 to P = 0.004), only 3/18 comparisons, one at MIC and two at FRC, exceeded the spirometry variability threshold. MLD and MLD-SD significantly increased with decreasing volumes, and were significantly larger in lower compared to upper lobes (P < 0.001). Lung volumetric differences provided by different software packages are small. These differences should not be interpreted based on statistical significance alone, but together with absolute volumetric differences. (orig.)

  17. Software package for modeling spin-orbit motion in storage rings

    Science.gov (United States)

    Zyuzin, D. V.

    2015-12-01

    A software package providing a graphical user interface for computer experiments on the motion of charged particle beams in accelerators, as well as analysis of obtained data, is presented. The software package was tested in the framework of the international project on electric dipole moment measurement JEDI (Jülich Electric Dipole moment Investigations). The specific features of particle spin motion imply the requirement to use a cyclic accelerator (storage ring) consisting of electrostatic elements, which makes it possible to preserve horizontal polarization for a long time. Computer experiments study the dynamics of 106-109 particles in a beam during 109 turns in an accelerator (about 1012-1015 integration steps for the equations of motion). For designing an optimal accelerator structure, a large number of computer experiments on polarized beam dynamics are required. The numerical core of the package is COSY Infinity, a program for modeling spin-orbit dynamics.

  18. Software package for modeling spin–orbit motion in storage rings

    Energy Technology Data Exchange (ETDEWEB)

    Zyuzin, D. V., E-mail: d.zyuzin@fz-juelich.de [St. Petersburg State University (Russian Federation)

    2015-12-15

    A software package providing a graphical user interface for computer experiments on the motion of charged particle beams in accelerators, as well as analysis of obtained data, is presented. The software package was tested in the framework of the international project on electric dipole moment measurement JEDI (Jülich Electric Dipole moment Investigations). The specific features of particle spin motion imply the requirement to use a cyclic accelerator (storage ring) consisting of electrostatic elements, which makes it possible to preserve horizontal polarization for a long time. Computer experiments study the dynamics of 10{sup 6}–10{sup 9} particles in a beam during 10{sup 9} turns in an accelerator (about 10{sup 12}–10{sup 15} integration steps for the equations of motion). For designing an optimal accelerator structure, a large number of computer experiments on polarized beam dynamics are required. The numerical core of the package is COSY Infinity, a program for modeling spin–orbit dynamics.

  19. User-friendly software for SANS data reduction and analysis

    International Nuclear Information System (INIS)

    Biemann, P.; Haese-Seiller, M.; Staron, P.

    1999-01-01

    At the Geesthacht Neutron Facility (GeNF) a new software is being developed for the reduction of two-dimensional small-angle neutron scattering (SANS) data. The main motivation for this work was to created software for users of our SANS facilities that is easy to use. Another motivation was to provide users with software they can also use at their home institute. Therefore, the software is implemented on a personal computer running WINDOWS. The program reads raw data from an area detector in binary or ascii format and produces ascii files containing the scattering curve. The cross section can be averaged over the whole area of the detector or over users defined sectors only. Scripts can be created for processing large numbers of files. (author)

  20. MEASURE/ANOMTEST. Anomaly detection software package for the Dodewaard power plant facility. Supplement 1. Extension of measurement analysis part, addition of plot package

    International Nuclear Information System (INIS)

    Schoonewelle, H.

    1995-01-01

    The anomaly detection software package installed at the Dodewaard nuclear power plant has been revised with respect to the part of the measurement analysis. A plot package has been added to the package. Signals in which an anomaly has been detected are automatically plotted including the uncertainty margins of the signals. This report gives a description of the revised measurement analysis part and the plot package. Each new routine of the plot package is described briefly and the new input and output files are given. (orig.)

  1. NEAMS Software Licensing, Release, and Distribution: Implications for FY2013 Work Package Planning

    International Nuclear Information System (INIS)

    Bernholdt, David E.

    2012-01-01

    The vision of the NEAMS program is to bring truly predictive modeling and simulation (M and S) capabilities to the nuclear engineering community in order to enable a new approach to the analysis of nuclear systems. NEAMS anticipates issuing in FY 2018 a full release of its computational 'Fermi Toolkit' aimed at advanced reactor and fuel cycles. The NEAMS toolkit involves extensive software development activities, some of which have already been underway for several years, however, the Advanced Modeling and Simulation Office (AMSO), which sponsors the NEAMS program, has not yet issued any official guidance regarding software licensing, release, and distribution policies. This motivated an FY12 task in the Capability Transfer work package to develop and recommend an appropriate set of policies. The current preliminary report is intended to provide awareness of issues with implications for work package planning for FY13. We anticipate a small amount of effort associated with putting into place formal licenses and contributor agreements for NEAMS software which doesn't already have them. We do not anticipate any additional effort or costs associated with software release procedures or schedules beyond those dictated by the quality expectations for the software. The largest potential costs we anticipate would be associated with the setup and maintenance of shared code repositories for development and early access to NEAMS software products. We also anticipate an opportunity, with modest associated costs, to work with the Radiation Safety Information Computational Center (RSICC) to clarify export control assessment policies for software under development.

  2. Acoustic performance design and optimal allocation of sound package in ship cabin noise reduction

    Directory of Open Access Journals (Sweden)

    YANG Deqing

    2017-08-01

    Full Text Available The sound package in noise reduction design of ship cabins has become the main approach for the future. The sound package is a specially designed acoustic component consisting of damping materials, absorption materials, sound isolation materials and base structural materials which can achieve the prescribed performance of noise reduction. Based on the Statistical Energy Analysis(SEAmethod, quick evaluation and design methods, and the optimal allocation theory of sound packages are investigated. The standard numerical acoustic performance evaluation model, sound package optimization design model and sound package optimal allocation model are presented. A genetic algorithm is applied to solve the presented optimization problems. Design examples demonstrate the validity and efficiency of the proposed models and solutions. The presented theory and methods benefit the standardization and programming of sound package design, and decrease noise reduction costs.

  3. Beyond filtered backprojection: A reconstruction software package for ion beam microtomography data

    Science.gov (United States)

    Habchi, C.; Gordillo, N.; Bourret, S.; Barberet, Ph.; Jovet, C.; Moretto, Ph.; Seznec, H.

    2013-01-01

    A new version of the TomoRebuild data reduction software package is presented, for the reconstruction of scanning transmission ion microscopy tomography (STIMT) and particle induced X-ray emission tomography (PIXET) images. First, we present a state of the art of the reconstruction codes available for ion beam microtomography. The algorithm proposed here brings several advantages. It is a portable, multi-platform code, designed in C++ with well-separated classes for easier use and evolution. Data reduction is separated in different steps and the intermediate results may be checked if necessary. Although no additional graphic library or numerical tool is required to run the program as a command line, a user friendly interface was designed in Java, as an ImageJ plugin. All experimental and reconstruction parameters may be entered either through this plugin or directly in text format files. A simple standard format is proposed for the input of experimental data. Optional graphic applications using the ROOT interface may be used separately to display and fit energy spectra. Regarding the reconstruction process, the filtered backprojection (FBP) algorithm, already present in the previous version of the code, was optimized so that it is about 10 times as fast. In addition, Maximum Likelihood Expectation Maximization (MLEM) and its accelerated version Ordered Subsets Expectation Maximization (OSEM) algorithms were implemented. A detailed user guide in English is available. A reconstruction example of experimental data from a biological sample is given. It shows the capability of the code to reduce noise in the sinograms and to deal with incomplete data, which puts a new perspective on tomography using low number of projections or limited angle.

  4. Global review of open access risk assessment software packages valid for global or continental scale analysis

    Science.gov (United States)

    Daniell, James; Simpson, Alanna; Gunasekara, Rashmin; Baca, Abigail; Schaefer, Andreas; Ishizawa, Oscar; Murnane, Rick; Tijssen, Annegien; Deparday, Vivien; Forni, Marc; Himmelfarb, Anne; Leder, Jan

    2015-04-01

    Over the past few decades, a plethora of open access software packages for the calculation of earthquake, volcanic, tsunami, storm surge, wind and flood have been produced globally. As part of the World Bank GFDRR Review released at the Understanding Risk 2014 Conference, over 80 such open access risk assessment software packages were examined. Commercial software was not considered in the evaluation. A preliminary analysis was used to determine whether the 80 models were currently supported and if they were open access. This process was used to select a subset of 31 models that include 8 earthquake models, 4 cyclone models, 11 flood models, and 8 storm surge/tsunami models for more detailed analysis. By using multi-criteria analysis (MCDA) and simple descriptions of the software uses, the review allows users to select a few relevant software packages for their own testing and development. The detailed analysis evaluated the models on the basis of over 100 criteria and provides a synopsis of available open access natural hazard risk modelling tools. In addition, volcano software packages have since been added making the compendium of risk software tools in excess of 100. There has been a huge increase in the quality and availability of open access/source software over the past few years. For example, private entities such as Deltares now have an open source policy regarding some flood models (NGHS). In addition, leaders in developing risk models in the public sector, such as Geoscience Australia (EQRM, TCRM, TsuDAT, AnuGA) or CAPRA (ERN-Flood, Hurricane, CRISIS2007 etc.), are launching and/or helping many other initiatives. As we achieve greater interoperability between modelling tools, we will also achieve a future wherein different open source and open access modelling tools will be increasingly connected and adapted towards unified multi-risk model platforms and highly customised solutions. It was seen that many software tools could be improved by enabling user

  5. Strategy and Software Application of Fresh Produce Package Design to Attain Optimal Modified Atmosphere

    Directory of Open Access Journals (Sweden)

    Dong Sun Lee

    2014-01-01

    Full Text Available Modified atmosphere packaging of fresh produce relies on the attainment of desired gas concentration inside the package resulting from product respiration and package’s gas transfer. Systematic package design method to achieve the target modified atmosphere was developed and constructed as software in terms of selecting the most appropriate film, microperforations, and/or CO2 scavenger. It incorporates modeling and/or database construction on the produce respiration, gas transfer across the plastic film and microperforation, and CO2 absorption by the scavenger. The optimization algorithm first selects the packaging film and/or microperforations to have the target O2 concentration in response to the respiration and then tunes the CO2 concentration by CO2 absorber when it goes above its tolerance limit. The optimization method tested for green pepper, strawberry, and king oyster mushroom packages was shown to be effective to design the package and the results obtained were consistent with literature work and experimental atmosphere.

  6. Recent developments on PLASMAKIN - a software package to model the kinetics in gas discharges

    International Nuclear Information System (INIS)

    Pinhao, N R

    2009-01-01

    PLASMAKIN is a user-friendly software package to handle physical and chemical data used in plasma physics modeling and to compute the production and destruction terms in fluid models equations. These terms account for the particle or energy production and loss rates due to gas-phase and gas-surface reactions. The package has been restructured and expanded to (a) allow the simulation of atomic emission spectra taking into account line broadening processes and radiation trapping; (b) include a library to compute the electron kinetics; (c) include a database of species properties and reactions and, (d) include a Python interface to allow access from scripts and integration with other scientific software tools.

  7. Three dimensional field computation software package DE3D and its applications

    International Nuclear Information System (INIS)

    Fan Mingwu; Zhang Tianjue; Yan Weili

    1992-07-01

    A software package, DE3D that can be run on PC for three dimensional electrostatic and magnetostatic field analysis has been developed in CIAE (China Institute of Atomic Energy). Two scalar potential method and special numerical techniques have made the code with high precision. It can be used for electrostatic and magnetostatic fields computations with complex boundary conditions. In the most cases, the result accuracy is better than 1% comparing with the measured. In some situations, the results are more acceptable than the other codes because some tricks are used for the current integral. Typical examples, design of a cyclotron magnet and magnetic elements on its beam transport line, given in the paper show how the program helps the designer to improve the design of the product. The software package could bring advantages to the producers and designers

  8. Novel applications of the x-ray tracing software package McXtrace

    DEFF Research Database (Denmark)

    Bergbäck Knudsen, Erik; Nielsen, Martin Meedom; Haldrup, Kristoffer

    2014-01-01

    We will present examples of applying the X-ray tracing software package McXtrace to different kinds of X-ray scattering experiments. In particular we will be focusing on time-resolved type experiments. Simulations of full scale experiments are particularly useful for this kind, especially when...... some of the issues encountered. Generally more than one or all of these effects are present at once. Simulations can in these cases be used to identify distinct footprints of such distortions and thus give the experimenter a means of deconvoluting them from the signal. We will present a study...... of this kind along with the newest developments of the McXtrace software package....

  9. The GeoSteiner software package for computing Steiner trees in the plane

    DEFF Research Database (Denmark)

    Juhl, Daniel; Warme, David M.; Winter, Pawel

    The GeoSteiner software package has for more than 10 years been the fastest (publicly available) program for computing exact solutions to Steiner tree problems in the plane. The computational study by Warme, Winter and Zachariasen, published in 2000, documented the performance of the GeoSteiner...... approach --- allowing the exact solution of Steiner tree problems with more than a thousand terminals. Since then, a number of algorithmic enhancements have improved the performance of the software package significantly. In this computational study we run the current code on the largest problem instances...... from the 2000-study, and on a number of larger problem instances. The computational study is performed using both the publicly available GeoSteiner 3.1 code base, and the commercial GeoSteiner 4.0 code base....

  10. ACEMAN (II): a PDP-11 software package for acoustic emission analysis

    International Nuclear Information System (INIS)

    Tobias, A.

    1976-01-01

    A powerful, but easy-to-use, software package (ACEMAN) for acoustic emission analysis has been developed at Berkeley Nuclear Laboratories. The system is based on a PDP-11 minicomputer with 24 K of memory, an RK05 DISK Drive and a Tektronix 4010 Graphics terminal. The operation of the system is described in detail in terms of the functions performed in response to the various command mnemonics. The ACEMAN software package offers many useful facilities not found on other acoustic emission monitoring systems. Its main features, many of which are unique, are summarised. The ACEMAN system automatically handles arrays of up to 12 sensors in real-time operation during which data are acquired, analysed, stored on the computer disk for future analysis and displayed on the terminal if required. (author)

  11. WannierTools: An open-source software package for novel topological materials

    Science.gov (United States)

    Wu, QuanSheng; Zhang, ShengNan; Song, Hai-Feng; Troyer, Matthias; Soluyanov, Alexey A.

    2018-03-01

    We present an open-source software package WannierTools, a tool for investigation of novel topological materials. This code works in the tight-binding framework, which can be generated by another software package Wannier90 (Mostofi et al., 2008). It can help to classify the topological phase of a given material by calculating the Wilson loop, and can get the surface state spectrum, which is detected by angle resolved photoemission (ARPES) and in scanning tunneling microscopy (STM) experiments. It also identifies positions of Weyl/Dirac points and nodal line structures, calculates the Berry phase around a closed momentum loop and Berry curvature in a part of the Brillouin zone (BZ).

  12. Determination of stress-strain state of the wooden church log walls with software package

    Directory of Open Access Journals (Sweden)

    Chulkova Anastasia

    2016-01-01

    Full Text Available The restoration of architectural monuments is going on all over the world today. The main aim of restoration is the renewal of stable functioning of building constructions in normal state. In this article, we have tried to figure out with special software the bearing capacity of log cabins of the Church of Transfiguration on Kizhi island. As shown in research results, determination of stress-strain stage with software package is necessary for the bearing capacity computation as well as field tests.

  13. PsyToolkit: a software package for programming psychological experiments using Linux.

    Science.gov (United States)

    Stoet, Gijsbert

    2010-11-01

    PsyToolkit is a set of software tools for programming psychological experiments on Linux computers. Given that PsyToolkit is freely available under the Gnu Public License, open source, and designed such that it can easily be modified and extended for individual needs, it is suitable not only for technically oriented Linux users, but also for students, researchers on small budgets, and universities in developing countries. The software includes a high-level scripting language, a library for the programming language C, and a questionnaire presenter. The software easily integrates with other open source tools, such as the statistical software package R. PsyToolkit is designed to work with external hardware (including IoLab and Cedrus response keyboards and two common digital input/output boards) and to support millisecond timing precision. Four in-depth examples explain the basic functionality of PsyToolkit. Example 1 demonstrates a stimulus-response compatibility experiment. Example 2 demonstrates a novel mouse-controlled visual search experiment. Example 3 shows how to control light emitting diodes using PsyToolkit, and Example 4 shows how to build a light-detection sensor. The last two examples explain the electronic hardware setup such that they can even be used with other software packages.

  14. Evaluation of Different Software Packages in Flow Modeling under Bridge Structures

    Directory of Open Access Journals (Sweden)

    Mohammad Taghi Dastorani

    2007-01-01

    Full Text Available This study is an independent and a comparative research concerning the accuracy, capability and suitability of three well-known packages ofISIS, MIKE11 and HEC-RAS as hydraulic river modeling software packages for modeling the flow through bridges. The research project was designed to assess the ability of each software package to model the flow through bridge structures. It was carried out using the data taken from experiments completed by a 22-meter laboratory flume at theUniversityofBirmingham. The flume has a compound cross section containing a main channel and two flood plains on either side. For this study a smooth main channel and a smooth floodplain have been assumed. Two types of bridges are modeled in this research; a multiple opening semi-circular arch bridge and a single opening straight deck bridge. For each bridge, two different simulations were carried out using two different upstream boundaries as low flow and high flow simulations. According to the results, all three packages were able to model arch and US BPR bridges but in some cases they presented different results. The highest water elevation upstream the bridge (maximum afflux was the main parameter to be compared to the measured values.ISISand HEC-RAS (especially HEC-RAS seem to be more efficient to model arch bridge. However, in some cases, MIKE 11 produced considerably higher results than those of the other two packages. To model USBPR bridge, all three packages produced reasonable results. However, the results by HEC-RAS are the best when the outputs are compared to the experimental data.

  15. Quantitation of magnetic resonance spectroscopy signals: the jMRUI software package

    Czech Academy of Sciences Publication Activity Database

    Stefan, D.; Di Cesare, F.; Andrasescu, A.; Popa, E.; Lazariev, A.; Vescovo, E.; Štrbák, Oliver; Williams, S.; Starčuk jr., Zenon; Cabanas, M.; van Ormondt, D.; Graveron-Demilly, D.

    2009-01-01

    Roč. 20, č. 10 (2009), 104035:1-9 ISSN 0957-0233 Grant - others:EC 6FP(XE) MRTN-CT-2006-035801 Source of funding: R - rámcový projekt EK Keywords : MR spectroscopy * MRS * MRSI * HRMAS-NMR * jMRUI software package * Java * plug-ins * quantitation Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.317, year: 2009

  16. Implementation of the INSPECT software package for statistical calculation in nuclear material accountability

    International Nuclear Information System (INIS)

    Marzo, M.A.S.

    1986-01-01

    The INSPECT software package was developed in the Pacific Northwest Laboratory for statistical calculations in nuclear material accountability. The programs apply the inspection and evaluation methodology described in Part of the Safeguards Technical Manual. In this paper the implementation of INSPECT at the Safeguards Division of CNEN, and the main characteristics of INSPECT are described. The potential applications of INSPECT to the nuclear material accountability is presented. (Author) [pt

  17. Software packages for simulating groundwater flow and the spreading of soluble and insoluble admixtures in aquifers

    International Nuclear Information System (INIS)

    Roshal, A.A.; Klein, I.S.; Svishchov, A.M.

    1993-01-01

    Software programs are described designed for solving hydrogeological and environmental problems related to the analysis and prediction of groundwater flow and the spreading of solutes and insolubles in the saturated zones. The software package GWFS (Ground Water Flow Simulation) allows for simulating steady-state and unsteady-state flow in confined, unconfined, and confined-unconfined multi-layer and quasi-3D isotropic and anisotropic aquifer systems. Considered are intra-layer sources and sinks, infiltration, inter-layer leakages, the interrelationships with surface reservoirs and streams, interrelationships with the drains, aquifer discharge to surface sources. The MTS (Mass Transport Simulation) package is designed for solving solute transport problems. Taken into account is convective transport, hydrodynamic dispersion and diffusion, linear equilibrium sorption. The method of characteristics is being implemented here using the ''particles-in-cells'' scheme in which the transport is modeled with the help of tracers. The software package OWFS (Oil-Water Flow Simulation) is designed for the simulation of hydrocarbon (oil-water) migration in aquifers

  18. An open-source software package for multivariate modeling and clustering: applications to air quality management.

    Science.gov (United States)

    Wang, Xiuquan; Huang, Guohe; Zhao, Shan; Guo, Junhong

    2015-09-01

    This paper presents an open-source software package, rSCA, which is developed based upon a stepwise cluster analysis method and serves as a statistical tool for modeling the relationships between multiple dependent and independent variables. The rSCA package is efficient in dealing with both continuous and discrete variables, as well as nonlinear relationships between the variables. It divides the sample sets of dependent variables into different subsets (or subclusters) through a series of cutting and merging operations based upon the theory of multivariate analysis of variance (MANOVA). The modeling results are given by a cluster tree, which includes both intermediate and leaf subclusters as well as the flow paths from the root of the tree to each leaf subcluster specified by a series of cutting and merging actions. The rSCA package is a handy and easy-to-use tool and is freely available at http://cran.r-project.org/package=rSCA . By applying the developed package to air quality management in an urban environment, we demonstrate its effectiveness in dealing with the complicated relationships among multiple variables in real-world problems.

  19. The DEEP-South: Scheduling and Data Reduction Software System

    Science.gov (United States)

    Yim, Hong-Suh; Kim, Myung-Jin; Bae, Youngho; Moon, Hong-Kyu; Choi, Young-Jun; Roh, Dong-Goo; the DEEP-South Team

    2015-08-01

    The DEep Ecliptic Patrol of the Southern sky (DEEP-South), started in October 2012, is currently in test runs with the first Korea Microlensing Telescope Network (KMTNet) 1.6 m wide-field telescope located at CTIO in Chile. While the primary objective for the DEEP-South is physical characterization of small bodies in the Solar System, it is expected to discover a large number of such bodies, many of them previously unknown.An automatic observation planning and data reduction software subsystem called "The DEEP-South Scheduling and Data reduction System" (the DEEP-South SDS) is currently being designed and implemented for observation planning, data reduction and analysis of huge amount of data with minimum human interaction. The DEEP-South SDS consists of three software subsystems: the DEEP-South Scheduling System (DSS), the Local Data Reduction System (LDR), and the Main Data Reduction System (MDR). The DSS manages observation targets, makes decision on target priority and observation methods, schedules nightly observations, and archive data using the Database Management System (DBMS). The LDR is designed to detect moving objects from CCD images, while the MDR conducts photometry and reconstructs lightcurves. Based on analysis made at the LDR and the MDR, the DSS schedules follow-up observation to be conducted at other KMTNet stations. In the end of 2015, we expect the DEEP-South SDS to achieve a stable operation. We also have a plan to improve the SDS to accomplish finely tuned observation strategy and more efficient data reduction in 2016.

  20. Evaluation of Solid Rocket Motor Component Data Using a Commercially Available Statistical Software Package

    Science.gov (United States)

    Stefanski, Philip L.

    2015-01-01

    Commercially available software packages today allow users to quickly perform the routine evaluations of (1) descriptive statistics to numerically and graphically summarize both sample and population data, (2) inferential statistics that draws conclusions about a given population from samples taken of it, (3) probability determinations that can be used to generate estimates of reliability allowables, and finally (4) the setup of designed experiments and analysis of their data to identify significant material and process characteristics for application in both product manufacturing and performance enhancement. This paper presents examples of analysis and experimental design work that has been conducted using Statgraphics®(Registered Trademark) statistical software to obtain useful information with regard to solid rocket motor propellants and internal insulation material. Data were obtained from a number of programs (Shuttle, Constellation, and Space Launch System) and sources that include solid propellant burn rate strands, tensile specimens, sub-scale test motors, full-scale operational motors, rubber insulation specimens, and sub-scale rubber insulation analog samples. Besides facilitating the experimental design process to yield meaningful results, statistical software has demonstrated its ability to quickly perform complex data analyses and yield significant findings that might otherwise have gone unnoticed. One caveat to these successes is that useful results not only derive from the inherent power of the software package, but also from the skill and understanding of the data analyst.

  1. Radiative transfer modeling through terrestrial atmosphere and ocean accounting for inelastic processes: Software package SCIATRAN

    International Nuclear Information System (INIS)

    Rozanov, V.V.; Dinter, T.; Rozanov, A.V.; Wolanin, A.; Bracher, A.; Burrows, J.P.

    2017-01-01

    SCIATRAN is a comprehensive software package which is designed to model radiative transfer processes in the terrestrial atmosphere and ocean in the spectral range from the ultraviolet to the thermal infrared (0.18–40 μm). It accounts for multiple scattering processes, polarization, thermal emission and ocean–atmosphere coupling. The main goal of this paper is to present a recently developed version of SCIATRAN which takes into account accurately inelastic radiative processes in both the atmosphere and the ocean. In the scalar version of the coupled ocean–atmosphere radiative transfer solver presented by Rozanov et al. we have implemented the simulation of the rotational Raman scattering, vibrational Raman scattering, chlorophyll and colored dissolved organic matter fluorescence. In this paper we discuss and explain the numerical methods used in SCIATRAN to solve the scalar radiative transfer equation including trans-spectral processes, and demonstrate how some selected radiative transfer problems are solved using the SCIATRAN package. In addition we present selected comparisons of SCIATRAN simulations with those published benchmark results, independent radiative transfer models, and various measurements from satellite, ground-based, and ship-borne instruments. The extended SCIATRAN software package along with a detailed User's Guide is made available for scientists and students, who are undertaking their own research typically at universities, via the web page of the Institute of Environmental Physics (IUP), University of Bremen: (http://www.iup.physik.uni-bremen.de). - Highlights: • A new version of the software package SCIATRAN is presented. • Inelastic scattering in water and atmosphere is implemented in SCIATRAN. • Raman scattering and fluorescence can be included in radiative transfer calculations. • Comparisons to other radiative transfer models show excellent agreement. • Comparisons to observations show consistent results.

  2. Software package evaluation for the TJ-II Data Acquisition System

    International Nuclear Information System (INIS)

    Cremy, C.; Sanchez, E.; Portas, A.; Vega, J.

    1996-01-01

    The TJ-II Data Acquisition System (DAS) has to provide a user interface which will allow setup for sampling channels, discharge signal visualization and reduce data processing, all in run time. On the other hand, the DAS will provide a high level software capability for signal analysis, processing and data visualization either in run time or off line. A set of software packages including Builder Xcessory, X-designer, llog Builder, Toolmaster, AVS 5, AVS/Express, PV-WAVE and Iris Explorer, have been evaluated by the Data Acquisition Group of the Fusion Division. the software evaluation, resumed in this paper, has resulted in a global solution being found which meets all of the DAS requirements. (Author)

  3. SWISTRACK - AN OPEN SOURCE, SOFTWARE PACKAGE APPLICABLE TO TRACKING OF FISH LOCOMOTION AND BEHAVIOUR

    DEFF Research Database (Denmark)

    Steffensen, John Fleng

    2010-01-01

    including swimming speed, acceleration and directionality of movements as well as the examination of locomotory panems during swimming. SWiSlrdL:k, a [n: t; and downloadable software package (available from www.sourceforge.com) is widely used for tracking robots, humans and other animals. Accordingly......, Swistrack can be easily adopted for the tracking offish. Benefits associated with the free software include: • Contrast or marker based tracking enabling tracking of either the whole animal, or tagged marks placed upon the animal • The ability to track multiple tags placed upon an individual animal • Highly...... effective background subtraction algorithms and filters ensuring smooth tracking of fish • Application of tags of different colour enables the software to track multiple fish without the problem of track exchange between individuals • Low processing requirements enable tracking in real-time • Further...

  4. Software package for the design and analysis of DNA origami structures

    DEFF Research Database (Denmark)

    Andersen, Ebbe Sloth; Nielsen, Morten Muhlig; Dong, Mingdong

    was observed on the mica surface with a fraction of the dolphin nanostructures showing extensive tail flexibility of approximately 90 degrees. The Java editor and tools are free software distributed under the GNU license. The open architecture of the editor makes it easy for the scientific community......A software package was developed for the semi-automated design of DNA origamis and further data analysis of Atomic Force Microscopy (AFM) images. As an example, we design the shape of a bottlenose dolphin and analyze it by means of high resolution AFM imaging. A high yield of DNA dolphins...... to contribute new tools and functionalities. Documentation, tutorials and software will be made available online....

  5. Improving package structure of object-oriented software using multi-objective optimization and weighted class connections

    Directory of Open Access Journals (Sweden)

    Amarjeet

    2017-07-01

    Full Text Available The software maintenance activities performed without following the original design decisions about the package structure usually deteriorate the quality of software modularization, leading to decay of the quality of the system. One of the main reasons for such structural deterioration is inappropriate grouping of source code classes in software packages. To improve such grouping/modular-structure, previous researchers formulated the software remodularization problem as an optimization problem and solved it using search-based meta-heuristic techniques. These optimization approaches aimed at improving the quality metrics values of the structure without considering the original package design decisions, often resulting into a totally new software modularization. The entirely changed software modularization becomes costly to realize as well as difficult to understand for the developers/maintainers. To alleviate this issue, we propose a multi-objective optimization approach to improve the modularization quality of an object-oriented system with minimum possible movement of classes between existing packages of original software modularization. The optimization is performed using NSGA-II, a widely-accepted multi-objective evolutionary algorithm. In order to ensure minimum modification of original package structure, a new approach of computing class relations using weighted strengths has been proposed here. The weights of relations among different classes are computed on the basis of the original package structure. A new objective function has been formulated using these weighted class relations. This objective function drives the optimization process toward better modularization quality simultaneously ensuring preservation of original structure. To evaluate the results of the proposed approach, a series of experiments are conducted over four real-worlds and two random software applications. The experimental results clearly indicate the effectiveness

  6. Radiative transfer modeling through terrestrial atmosphere and ocean accounting for inelastic processes: Software package SCIATRAN

    Science.gov (United States)

    Rozanov, V. V.; Dinter, T.; Rozanov, A. V.; Wolanin, A.; Bracher, A.; Burrows, J. P.

    2017-06-01

    SCIATRAN is a comprehensive software package which is designed to model radiative transfer processes in the terrestrial atmosphere and ocean in the spectral range from the ultraviolet to the thermal infrared (0.18-40 μm). It accounts for multiple scattering processes, polarization, thermal emission and ocean-atmosphere coupling. The main goal of this paper is to present a recently developed version of SCIATRAN which takes into account accurately inelastic radiative processes in both the atmosphere and the ocean. In the scalar version of the coupled ocean-atmosphere radiative transfer solver presented by Rozanov et al. [61] we have implemented the simulation of the rotational Raman scattering, vibrational Raman scattering, chlorophyll and colored dissolved organic matter fluorescence. In this paper we discuss and explain the numerical methods used in SCIATRAN to solve the scalar radiative transfer equation including trans-spectral processes, and demonstrate how some selected radiative transfer problems are solved using the SCIATRAN package. In addition we present selected comparisons of SCIATRAN simulations with those published benchmark results, independent radiative transfer models, and various measurements from satellite, ground-based, and ship-borne instruments. The extended SCIATRAN software package along with a detailed User's Guide is made available for scientists and students, who are undertaking their own research typically at universities, via the web page of the Institute of Environmental Physics (IUP), University of Bremen: http://www.iup.physik.uni-bremen.de.

  7. GMATA: An Integrated Software Package for Genome-Scale SSR Mining, Marker Development and Viewing.

    Science.gov (United States)

    Wang, Xuewen; Wang, Le

    2016-01-01

    Simple sequence repeats (SSRs), also referred to as microsatellites, are highly variable tandem DNAs that are widely used as genetic markers. The increasing availability of whole-genome and transcript sequences provides information resources for SSR marker development. However, efficient software is required to efficiently identify and display SSR information along with other gene features at a genome scale. We developed novel software package Genome-wide Microsatellite Analyzing Tool Package (GMATA) integrating SSR mining, statistical analysis and plotting, marker design, polymorphism screening and marker transferability, and enabled simultaneously display SSR markers with other genome features. GMATA applies novel strategies for SSR analysis and primer design in large genomes, which allows GMATA to perform faster calculation and provides more accurate results than existing tools. Our package is also capable of processing DNA sequences of any size on a standard computer. GMATA is user friendly, only requires mouse clicks or types inputs on the command line, and is executable in multiple computing platforms. We demonstrated the application of GMATA in plants genomes and reveal a novel distribution pattern of SSRs in 15 grass genomes. The most abundant motifs are dimer GA/TC, the A/T monomer and the GCG/CGC trimer, rather than the rich G/C content in DNA sequence. We also revealed that SSR count is a linear to the chromosome length in fully assembled grass genomes. GMATA represents a powerful application tool that facilitates genomic sequence analyses. GAMTA is freely available at http://sourceforge.net/projects/gmata/?source=navbar.

  8. A new vector radiative transfer model as a part of SCIATRAN 3.0 software package.

    Science.gov (United States)

    Rozanov, Alexei; Rozanov, Vladimir; Burrows, John P.

    The SCIATRAN 3.0 package is a result of further development of the SCIATRAN 2.x software family which, similar to previous versions, comprises a radiative transfer model and a retrieval block. A major improvement was achieved in comparison to previous software versions by adding the vector mode to the radiative transfer model. Thus, the well-established Discrete Ordinate solver can now be run in the vector mode to calculate the scattered solar radiation including polarization, i.e., to simulate all four components of the Stockes vector. Similar to the scalar version, the simulations can be performed for any viewing geometry typical for atmospheric observations in the UV-Vis-NIR spectral range (nadir, limb, off-axis, etc.) as well as for any observer position within or outside the Earth's atmosphere. Similar to the precursor version, the new model is freely available for non-commercial use via the web page of the University of Bremen. In this presentation a short description of the software package, especially of the new vector radiative transfer model will be given, including remarks on the availability for the scientific community. Furthermore, comparisons to other vector models will be shown and some example problems will be considered where the polarization of the observed radiation must be accounted for to obtain high quality results.

  9. The EQ3/6 software package for geochemical modeling: Current status

    International Nuclear Information System (INIS)

    Worlery, T.J.; Jackson, K.J.; Bourcier, W.L.; Bruton, C.J.; Viani, B.E.; Knauss, K.G.; Delany, J.M.

    1988-07-01

    EQ3/6 is a software package for modeling chemical and mineralogic interactions in aqueous geochemical systems. The major components of the package are EQ3NR (a speciation-solubility code), EQ6 (a reaction path code), EQLIB (a supporting library), and a supporting thermodynamic data base. EQ3NR calculates aqueous speciation and saturation indices from analytical data. It can also be used to calculate compositions of buffer solutions for use in laboratory experiments. EQ6 computes reaction path models of both equilibrium step processes and kinetic reaction processes. These models can be computed for closed systems and relatively simple open systems. EQ3/6 is useful in making purely theoretical calculations, in designing, interpreting, and extrapolating laboratory experiments, and in testing and developing submodels and supporting data used in these codes. The thermodynamic data base supports calculations over the range 0-300 degree C. 60 refs., 2 figs

  10. The EQ3/6 software package for geochemical modeling: Current status

    Energy Technology Data Exchange (ETDEWEB)

    Wolery, T.J.; Jackson, K.J.; Bourcier, W.L.; Bruton, C.J.; Viani, B.E.; Knauss, K.G.; Delany, J.M.

    1988-07-01

    EQ3/6 is a software package for modeling chemical and mineralogic interactions in aqueous geochemical systems. The major components of the package are EQ3NR (a speciation-solubility code), EQ6 (a reaction path code), EQLIB (a supporting library), and a supporting thermodynamic data base. EQ3NR calculates aqueous speciation and saturation indices from analytical data. It can also be used to calculate compositions of buffer solutions for use in laboratory experiments. EQ6 computes reaction path models of both equilibrium step processes and kinetic reaction processes. These models can be computed for closed systems and relatively simple open systems. EQ3/6 is useful in making purely theoretical calculations, in designing, interpreting, and extrapolating laboratory experiments, and in testing and developing submodels and supporting data used in these codes. The thermodynamic data base supports calculations over the range 0-300{degree}C. 60 refs., 2 figs.

  11. Validation of a Video Analysis Software Package for Quantifying Movement Velocity in Resistance Exercises.

    Science.gov (United States)

    Sañudo, Borja; Rueda, David; Pozo-Cruz, Borja Del; de Hoyo, Moisés; Carrasco, Luis

    2016-10-01

    Sañudo, B, Rueda, D, del Pozo-Cruz, B, de Hoyo, M, and Carrasco, L. Validation of a video analysis software package for quantifying movement velocity in resistance exercises. J Strength Cond Res 30(10): 2934-2941, 2016-The aim of this study was to establish the validity of a video analysis software package in measuring mean propulsive velocity (MPV) and the maximal velocity during bench press. Twenty-one healthy males (21 ± 1 year) with weight training experience were recruited, and the MPV and the maximal velocity of the concentric phase (Vmax) were compared with a linear position transducer system during a standard bench press exercise. Participants performed a 1 repetition maximum test using the supine bench press exercise. The testing procedures involved the simultaneous assessment of bench press propulsive velocity using 2 kinematic (linear position transducer and semi-automated tracking software) systems. High Pearson's correlation coefficients for MPV and Vmax between both devices (r = 0.473 to 0.993) were observed. The intraclass correlation coefficients for barbell velocity data and the kinematic data obtained from video analysis were high (>0.79). In addition, the low coefficients of variation indicate that measurements had low variability. Finally, Bland-Altman plots with the limits of agreement of the MPV and Vmax with different loads showed a negative trend, which indicated that the video analysis had higher values than the linear transducer. In conclusion, this study has demonstrated that the software used for the video analysis was an easy to use and cost-effective tool with a very high degree of concurrent validity. This software can be used to evaluate changes in velocity of training load in resistance training, which may be important for the prescription and monitoring of training programmes.

  12. Lung nodule volumetry: segmentation algorithms within the same software package cannot be used interchangeably

    Energy Technology Data Exchange (ETDEWEB)

    Ashraf, H.; Bach, K.S.; Hansen, H. [Copenhagen University, Department of Radiology, Gentofte Hospital, Hellerup (Denmark); Hoop, B. de [University Medical Centre Utrecht, Department of Radiology, Utrecht (Netherlands); Shaker, S.B.; Dirksen, A. [Copenhagen University, Department of Respiratory Medicine, Gentofte Hospital, Hellerup (Denmark); Prokop, M. [University Medical Centre Utrecht, Department of Radiology, Utrecht (Netherlands); Radboud University Nijmegen, Department of Radiology, Nijmegen (Netherlands); Pedersen, J.H. [Copenhagen University, Department of Cardiothoracic Surgery RT, Rigshospitalet, Copenhagen (Denmark)

    2010-08-15

    We examined the reproducibility of lung nodule volumetry software that offers three different volumetry algorithms. In a lung cancer screening trial, 188 baseline nodules >5 mm were identified. Including follow-ups, these nodules formed a study-set of 545 nodules. Nodules were independently double read by two readers using commercially available volumetry software. The software offers readers three different analysing algorithms. We compared the inter-observer variability of nodule volumetry when the readers used the same and different algorithms. Both readers were able to correctly segment and measure 72% of nodules. In 80% of these cases, the readers chose the same algorithm. When readers used the same algorithm, exactly the same volume was measured in 50% of readings and a difference of >25% was observed in 4%. When the readers used different algorithms, 83% of measurements showed a difference of >25%. Modern volumetric software failed to correctly segment a high number of screen detected nodules. While choosing a different algorithm can yield better segmentation of a lung nodule, reproducibility of volumetric measurements deteriorates substantially when different algorithms were used. It is crucial even in the same software package to choose identical parameters for follow-up. (orig.)

  13. Lung nodule volumetry: segmentation algorithms within the same software package cannot be used interchangeably

    International Nuclear Information System (INIS)

    Ashraf, H.; Bach, K.S.; Hansen, H.; Hoop, B. de; Shaker, S.B.; Dirksen, A.; Prokop, M.; Pedersen, J.H.

    2010-01-01

    We examined the reproducibility of lung nodule volumetry software that offers three different volumetry algorithms. In a lung cancer screening trial, 188 baseline nodules >5 mm were identified. Including follow-ups, these nodules formed a study-set of 545 nodules. Nodules were independently double read by two readers using commercially available volumetry software. The software offers readers three different analysing algorithms. We compared the inter-observer variability of nodule volumetry when the readers used the same and different algorithms. Both readers were able to correctly segment and measure 72% of nodules. In 80% of these cases, the readers chose the same algorithm. When readers used the same algorithm, exactly the same volume was measured in 50% of readings and a difference of >25% was observed in 4%. When the readers used different algorithms, 83% of measurements showed a difference of >25%. Modern volumetric software failed to correctly segment a high number of screen detected nodules. While choosing a different algorithm can yield better segmentation of a lung nodule, reproducibility of volumetric measurements deteriorates substantially when different algorithms were used. It is crucial even in the same software package to choose identical parameters for follow-up. (orig.)

  14. A software package to process an INIS magnetic tape on the VAX computer

    International Nuclear Information System (INIS)

    Omar, A.A.; Mohamed, F.A.

    1991-01-01

    This paper presents a software package whose function is to process the magnetic tapes distributed by the Atomic Energy Agency, on the VAX computers. These tapes contain abstracts of papers in the different branches of nuclear field and is supplied from the international Nuclear Information system (INIS). Two goals are aimed from this paper. First it gives a procedure to process any foreign magnetic tape on the VAX computers. Second, it solves the problem of reading the INIS tapes on a non IBM computer and thus allowing the specialists to gain from the large amount of information contained in these tapes. 11 fig

  15. SEJV2 software package for radiation monitoring system of WWER 440 NPP

    International Nuclear Information System (INIS)

    Kapisovsky, V.; Jancik, O.; Kubik, I.; Bena, J.

    1993-01-01

    The main part of the radiation monitoring system at a WWER-440 (213 reactor type) nuclear power plant is the centralized 400-channel monitoring system 'SEJVAL' servicing twin reactor units. The SEJV2 software package is described developed to run on a PC with an IFS2 interface to the SEJVAL radiation monitoring system. It provides enhanced data presentation, record keeping and report generation, thus improving the efficiency of the health physics shift. The system was for the first time implemented at the Jaslovske Bohunice V-2 nuclear power plant with encouraging results. (Z.S.) 3 refs

  16. VIPEX (Vital-area Identification Package EXpert) Software Verification and Validation

    International Nuclear Information System (INIS)

    Jung, Woo Sik; Suh, Jae Seung

    2010-06-01

    The purposes of this report are (1) to perform a Verification and Validation (V and V) test for the VIPEX(Vital-area Identification Package EXpert) software and (2) to improve a software quality through the V and V test. The VIPEX was developed in Korea Atomic Energy Research Institute (KAERI) for the Vital Area Identification (VAI) of nuclear power plants. The version of the VIPEX which was distributed is 3.2.0.0. The VIPEX was revised based on the first V and V test and the second V and V test was performed. We have performed the following tasks for the V and V test on Windows XP and VISTA operating systems: Ο Testing basic functions including fault tree editing Ο Testing all kind of functions Ο Research for update from Visual BASIC 6.0 to Visual BASIC 2008

  17. SLDAssay: A software package and web tool for analyzing limiting dilution assays.

    Science.gov (United States)

    Trumble, Ilana M; Allmon, Andrew G; Archin, Nancie M; Rigdon, Joseph; Francis, Owen; Baldoni, Pedro L; Hudgens, Michael G

    2017-11-01

    Serial limiting dilution (SLD) assays are used in many areas of infectious disease related research. This paper presents SLDAssay, a free and publicly available R software package and web tool for analyzing data from SLD assays. SLDAssay computes the maximum likelihood estimate (MLE) for the concentration of target cells, with corresponding exact and asymptotic confidence intervals. Exact and asymptotic goodness of fit p-values, and a bias-corrected (BC) MLE are also provided. No other publicly available software currently implements the BC MLE or the exact methods. For validation of SLDAssay, results from Myers et al. (1994) are replicated. Simulations demonstrate the BC MLE is less biased than the MLE. Additionally, simulations demonstrate that exact methods tend to give better confidence interval coverage and goodness-of-fit tests with lower type I error than the asymptotic methods. Additional advantages of using exact methods are also discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. ATK-ForceField: a new generation molecular dynamics software package

    Science.gov (United States)

    Schneider, Julian; Hamaekers, Jan; Chill, Samuel T.; Smidstrup, Søren; Bulin, Johannes; Thesen, Ralph; Blom, Anders; Stokbro, Kurt

    2017-12-01

    ATK-ForceField is a software package for atomistic simulations using classical interatomic potentials. It is implemented as a part of the Atomistix ToolKit (ATK), which is a Python programming environment that makes it easy to create and analyze both standard and highly customized simulations. This paper will focus on the atomic interaction potentials, molecular dynamics, and geometry optimization features of the software, however, many more advanced modeling features are available. The implementation details of these algorithms and their computational performance will be shown. We present three illustrative examples of the types of calculations that are possible with ATK-ForceField: modeling thermal transport properties in a silicon germanium crystal, vapor deposition of selenium molecules on a selenium surface, and a simulation of creep in a copper polycrystal.

  19. TensorPack: a Maple-based software package for the manipulation of algebraic expressions of tensors in general relativity

    International Nuclear Information System (INIS)

    Huf, P A; Carminati, J

    2015-01-01

    In this paper we: (1) introduce TensorPack, a software package for the algebraic manipulation of tensors in covariant index format in Maple; (2) briefly demonstrate the use of the package with an orthonormal tensor proof of the shearfree conjecture for dust. TensorPack is based on the Riemann and Canon tensor software packages and uses their functions to express tensors in an indexed covariant format. TensorPack uses a string representation as input and provides functions for output in index form. It extends the functionality to basic algebra of tensors, substitution, covariant differentiation, contraction, raising/lowering indices, symmetry functions and other accessory functions. The output can be merged with text in the Maple environment to create a full working document with embedded dynamic functionality. The package offers potential for manipulation of indexed algebraic tensor expressions in a flexible software environment. (paper)

  20. User’s Manual for the Simulation of Energy Consumption and Emissions from Rail Traffic Software Package

    DEFF Research Database (Denmark)

    Cordiero, Tiago M.; Lindgreen, Erik Bjørn Grønning; Sorenson, Spencer C

    2005-01-01

    The ARTEMIS rail emissions model was implemented in a Microsoft Excel software package that includes data from the GISCO database on railway traffic. This report is the user’s manual for the aforementioned software that includes information on how to run the program and an overview on how...... of Excel Macros (Visual Basic) and database sheets included in one Excel file...

  1. Ignominy: a tool for software dependency and metric analysis with examples from large HEP packages

    International Nuclear Information System (INIS)

    Tuura, L.A.; Taylor, L.

    2001-01-01

    Ignominy is a tool developed in the CMS IGUANA project to analyse the structure of software systems. Its primary component is a dependency scanner that distills information into human-usable forms. It also includes several tools to visualise the collected data in the form of graphical views and numerical metrics. Ignominy was designed to adapt to almost any reasonable structure, and it has been used to analyse several large projects. The original purpose of Ignominy was to help us better ensure the quality of our own software, and in particular warn us about possible structural problems early on. As a part of this activity it is now used as a standard part of our release procedure. The authors also use it to evaluate and study the quality of external packages they plan to make use of. The authors describe what Ignominy can find out, and how it can be used to visualise and assess a software structure. The authors also discuss the inherent problems of the analysis as well as the different approaches to modularity the tool makes quite evident. The focus is the illustration of these issues through the analysis results for several sizable HEP software projects

  2. Cross-Platform Learning Media Development of Software Installation on Computer Engineering and Networking Expertise Package

    Directory of Open Access Journals (Sweden)

    Afis Pratama

    2018-03-01

    Full Text Available Software Installation is one of the important lessons that must be mastered by student of computer and network engineering expertise package. But there is a problem about the lack of attention and concentration of students in following the teaching and learning process in the subject of installation of the software. The matter must immediately find a solution. This research refers to the technology development that is always increasing. The technology can be used as a tool to support learning activities. Currently, all grade 10 students in public vocational high school (SMK 8 Semarang Indonesia already have a gadget, either a smartphone or a laptop and the intensity of usage is high enough. Based on this phenomenon, this research aims to create a learning media software installation that is cross-platform. It is practical and can be carried easily in a smartphone and a laptop that has different operating system. So that, this media is expected to improve learning outcomes, understanding and enthusiasm of the students in the software installation lesson.

  3. Smile Analyzer: A Software Package for Analyzing the Characteristics of the Speech and Smile

    Directory of Open Access Journals (Sweden)

    Roozbeh Rashed

    2013-01-01

    Full Text Available Taking into account the factors related to lip-tooth relationships in orthodontic diagnosis and treatment planning is of prime importance. Manual quantitative analysis of facial parameters on photographs during smile and speech is a difficult and time-consuming job. Since there is no comprehensive and user-friendly software package, we developed a software program called "Smile Analyzer" in the Department of Orthodontics of Mashhad Faculty of Dentistry for measuring the parameters related to lip-tooth relationships and other facial landmarks on the photographs taken during various facial expressions. The software was designed using visual basic. NET and the ADO. NET was used for developing its Microsoft Access database. The program runs on Microsoft Windows. It is capable of analyzing many parameters or variables in many patients' photographs, although 19 more common variables are previously defined as a default list of variables. When all variables are measured or calculated, a report can be generated and saved in either PDF or MS Excel format. Data are readily transferable to statistical software like SPSS for Windows.  

  4. Smile Analyzer: A Software Package for Analyzing the Characteristics of the Speech and Smile

    Directory of Open Access Journals (Sweden)

    Farzin Heravi

    2012-09-01

    Full Text Available Taking into account the factors related to lip-tooth relationships in orthodontic diagnosis and treatment planning is of prime importance. Manual quantitative analysis of facial parameters on photographs during smile and speech is a difficult and time-consuming job. Since there is no comprehensive and user-friendly software package, we developed a software program called "Smile Analyzer" in the Department of Orthodontics of Mashhad Faculty of Dentistry for measuring the parameters related to lip-tooth relationships and other facial landmarks on the photographs taken during various facial expressions. The software was designed using visual basic. NET and the ADO. NET was used for developing its Microsoft Access database. The program runs on Microsoft Windows. It is capable of analyzing many parameters or variables in many patients' photographs, although 19 more common variables are previously defined as a default list of variables. When all variables are measured or calculated, a report can be generated and saved in either PDF or MS Excel format. Data are readily transferable to statistical software like SPSS for Windows.

  5. Diffusion tensor imaging of the median nerve: intra-, inter-reader agreement, and agreement between two software packages

    International Nuclear Information System (INIS)

    Guggenberger, Roman; Nanz, Daniel; Puippe, Gilbert; Andreisek, Gustav; Rufibach, Kaspar; White, Lawrence M.; Sussman, Marshall S.

    2012-01-01

    To assess intra-, inter-reader agreement, and the agreement between two software packages for magnetic resonance diffusion tensor imaging (DTI) measurements of the median nerve. Fifteen healthy volunteers (seven men, eight women; mean age, 31.2 years) underwent DTI of both wrists at 1.5 T. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) of the median nerve were measured by three readers using two commonly used software packages. Measurements were repeated by two readers after 6 weeks. Intraclass correlation coefficients (ICC) and Bland-Altman analysis were used for statistical analysis. ICCs for intra-reader agreement ranged from 0.87 to 0.99, for inter-reader agreement from 0.62 to 0.83, and between the two software packages from 0.63 to 0.82. Bland-Altman analysis showed no differences for intra- and inter-reader agreement and agreement between software packages. The intra-, inter-reader, and agreement between software packages for DTI measurements of the median nerve were moderate to substantial suggesting that user- and software-dependent factors contribute little to variance in DTI measurements. (orig.)

  6. SeDA: A software package for the statistical analysis of the instrument drift

    International Nuclear Information System (INIS)

    Lee, H. J.; Jang, S. C.; Lim, T. J.

    2006-01-01

    The setpoints for safety-related equipment are affected by many sources of an uncertainty. ANSI/ISA-S67.04.01-2000 [1] and ISA-RP6 7.04.02-2000 [2] suggested the statistical approaches for ensuring that the safety-related instrument setpoints were established and maintained within the technical specification limits [3]. However, Jang et al. [4] indicated that the preceding methodologies for a setpoint drift analysis might be insufficient to manage a setpoint drift on an instrumentation device and proposed new statistical analysis procedures for the management of a setpoint drift, based on the plant specific as-found/as-left data. Although IHPA (Instrument History Performance Analysis) is a widely known commercial software package to analyze an instrument setpoint drift, several steps in the new procedure cannot be performed by using it because it is based on the statistical approaches suggested in the ANSI/ISA-S67.04.01 -2000 [1] and ISA-RP67.04.02-2000 [2], In this paper we present a software package (SeDA: Setpoint Drift Analysis) that implements new methodologies, and which is easy to use, as it is accompanied by powerful graphical tools. (authors)

  7. Graphical representation of ribosomal RNA probe accessibility data using ARB software package

    Directory of Open Access Journals (Sweden)

    Amann Rudolf

    2005-03-01

    Full Text Available Abstract Background Taxon specific hybridization probes in combination with a variety of commonly used hybridization formats nowadays are standard tools in microbial identification. A frequently applied technology, fluorescence in situ hybridization (FISH, besides single cell identification, allows the localization and functional studies of the microbial community composition. Careful in silico design and evaluation of potential oligonucleotide probe targets is therefore crucial for performing successful hybridization experiments. Results The PROBE Design tools of the ARB software package take into consideration several criteria such as number, position and quality of diagnostic sequence differences while designing oligonucleotide probes. Additionally, new visualization tools were developed to enable the user to easily examine further sequence associated criteria such as higher order structure, conservation, G+C content, transition-transversion profiles and in situ target accessibility patterns. The different types of sequence associated information (SAI can be visualized by user defined background colors within the ARB primary and secondary structure editors as well as in the PROBE Match tool. Conclusion Using this tool, in silico probe design and evaluation can be performed with respect to in situ probe accessibility data. The evaluation of proposed probe targets with respect to higher-order rRNA structure is of importance for successful design and performance of in situ hybridization experiments. The entire ARB software package along with the probe accessibility data is available from the ARB home page http://www.arb-home.de.

  8. PHYLUCE is a software package for the analysis of conserved genomic loci.

    Science.gov (United States)

    Faircloth, Brant C

    2016-03-01

    Targeted enrichment of conserved and ultraconserved genomic elements allows universal collection of phylogenomic data from hundreds of species at multiple time scales ( 300 Ma). Prior to downstream inference, data from these types of targeted enrichment studies must undergo preprocessing to assemble contigs from sequence data; identify targeted, enriched loci from the off-target background data; align enriched contigs representing conserved loci to one another; and prepare and manipulate these alignments for subsequent phylogenomic inference. PHYLUCE is an efficient and easy-to-install software package that accomplishes these tasks across hundreds of taxa and thousands of enriched loci. PHYLUCE is written for Python 2.7. PHYLUCE is supported on OSX and Linux (RedHat/CentOS) operating systems. PHYLUCE source code is distributed under a BSD-style license from https://www.github.com/faircloth-lab/phyluce/ PHYLUCE is also available as a package (https://binstar.org/faircloth-lab/phyluce) for the Anaconda Python distribution that installs all dependencies, and users can request a PHYLUCE instance on iPlant Atmosphere (tag: phyluce). The software manual and a tutorial are available from http://phyluce.readthedocs.org/en/latest/ and test data are available from doi: 10.6084/m9.figshare.1284521. brant@faircloth-lab.org Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  9. Perprof-py: A Python Package for Performance Profile of Mathematical Optimization Software

    Directory of Open Access Journals (Sweden)

    Abel Soares Siqueira

    2016-04-01

    Full Text Available A very important area of research in the field of Mathematical Optimization is the benchmarking of optimization packages to compare solvers. During benchmarking, one usually collects a large amount of information like CPU time, number of functions evaluations, number of iterations, and much more. This information, if presented as tables, can be difficult to analyze and compare due to large amount of data. Therefore tools to better process and understand optimization benchmark data have been developed. One of the most widespread tools is the Performance Profile graphics proposed by Dolan and Moré [2]. In this context, this paper describes perprof-py, a free/open source software that creates 'Performance Profile' graphics. This software produces graphics in PDF using LaTeX with PGF/TikZ [22] and PGFPLOTS [4] packages, in PNG using matplotlib [9], and in HTML using Bokeh [1]. Perprof-py can also be easily extended to be used with other plot libraries. It is implemented in Python 3 with support for internationalization, and is under the General Public License Version 3 (GPLv3.

  10. MORTICIA, a statistical analysis software package for determining optical surveillance system effectiveness.

    Science.gov (United States)

    Ramkilowan, A.; Griffith, D. J.

    2017-10-01

    Surveillance modelling in terms of the standard Detect, Recognise and Identify (DRI) thresholds remains a key requirement for determining the effectiveness of surveillance sensors. With readily available computational resources it has become feasible to perform statistically representative evaluations of the effectiveness of these sensors. A new capability for performing this Monte-Carlo type analysis is demonstrated in the MORTICIA (Monte- Carlo Optical Rendering for Theatre Investigations of Capability under the Influence of the Atmosphere) software package developed at the Council for Scientific and Industrial Research (CSIR). This first generation, python-based open-source integrated software package, currently in the alpha stage of development aims to provide all the functionality required to perform statistical investigations of the effectiveness of optical surveillance systems in specific or generic deployment theatres. This includes modelling of the mathematical and physical processes that govern amongst other components of a surveillance system; a sensor's detector and optical components, a target and its background as well as the intervening atmospheric influences. In this paper we discuss integral aspects of the bespoke framework that are critical to the longevity of all subsequent modelling efforts. Additionally, some preliminary results are presented.

  11. A PC-based software package for modeling DOE mixed-waste management options

    International Nuclear Information System (INIS)

    Abashian, M.S.; Carney, C.; Schum, K.

    1995-02-01

    The U.S. Department of Energy (DOE) Headquarters and associated contractors have developed an IBM PC-based software package that estimates costs, schedules, and public and occupational health risks for a range of mixed-waste management options. A key application of the software package is the comparison of various waste-treatment options documented in the draft Site Treatment Plans prepared in accordance with the requirements of the Federal Facility Compliance Act of 1992. This automated Systems Analysis Methodology consists of a user interface for configuring complexwide or site-specific waste-management options; calculational algorithms for cost, schedule and risk; and user-selected graphical or tabular output of results. The mixed-waste management activities modeled in the automated Systems Analysis Methodology include waste storage, characterization, handling, transportation, treatment, and disposal. Analyses of treatment options identified in the draft Site Treatment Plans suggest potential cost and schedule savings from consolidation of proposed treatment facilities. This paper presents an overview of the automated Systems Analysis Methodology

  12. REIDAC. A software package for retrospective dose assessment in internal contamination with radionuclides

    International Nuclear Information System (INIS)

    Kurihara, Osamu; Kanai, Katsuta; Takada, Chie; Takasaki, Koji; Ito, Kimio; Momose, Takumaro; Hato, Shinji; Ikeda, Hiroshi; Oeda, Mikihiro; Kurosawa, Naohiro; Fukutsu, Kumiko; Yamada, Yuji; Akashi, Makoto

    2007-01-01

    For cases of internal contamination with radionuclides, it is necessary to perform an internal dose assessment to facilitate radiation protection. For this purpose, the ICRP has supplied the dose coefficients and the retention and excretion rates for various radionuclides. However, these dosimetric quantities are calculated under typical conditions and are not necessarily detailed enough for dose assessment situations in which specific information on the incident or/and individual biokinetic characteristics could or should be taken into account retrospectively. This paper describes a newly developed PC-based software package called Retrospective Internal Dose Assessment Code (REIDAC) that meets the needs of retrospective dose assessment. REIDAC is made up of a series of calculation programs and a package of software. The former calculates the dosimetric quantities for any radionuclide being assessed and the latter provides a user with the graphical user interface (GUI) for executing the programs, editing parameter values and displaying results. The accuracy of REIDAC was verified by comparisons with dosimetric quantities given in the ICRP publications. This paper presents the basic structure of REIDAC and its calculation methods. Sensitivity analysis of the aerosol size for 239 Pu compounds and provisional calculations for wound contamination with 241 Am were performed as examples of the practical application of REIDAC. (author)

  13. METEOR v1.0 - Design and structure of the software package

    International Nuclear Information System (INIS)

    Palomo, E.

    1994-01-01

    This script describes the structure and the separated modules of the software package METEOR for the statistical analysis of meteorological data series. It contains a systematic description of the subroutines of METEOR and, also, of the required shape for input and output files. The original version of METEOR have been developed by Ph.D. Elena Palomo, CIEMAT-IER, GIMASE. It is built by linking programs and routines written in FORTRAN 77 and it adds thc graphical capabilities of GNUPLOT. The shape of this toolbox was designed following the criteria of modularity, flexibility and agility criteria. All the input, output and analysis options are structured in three main menus: i) the first is aimed to evaluate the quality of the data set; ii) the second is aimed for pre-processing of the data; and iii) the third is aimed towards the statistical analyses and for creating the graphical outputs. Actually the information about METEOR is constituted by three documents written in spanish: 1) METEOR v1.0: User's guide; 2) METEOR v1.0: A usage example; 3) METEOR v 1.0: Design and structure of the software package. (Author)

  14. Melanie II--a third-generation software package for analysis of two-dimensional electrophoresis images: II. Algorithms.

    Science.gov (United States)

    Appel, R D; Vargas, J R; Palagi, P M; Walther, D; Hochstrasser, D F

    1997-12-01

    After two generations of software systems for the analysis of two-dimensional electrophoresis (2-DE) images, a third generation of such software packages has recently emerged that combines state-of-the-art graphical user interfaces with comprehensive spot data analysis capabilities. A key characteristic common to most of these software packages is that many of their tools are implementations of algorithms that resulted from research areas such as image processing, vision, artificial intelligence or machine learning. This article presents the main algorithms implemented in the Melanie II 2-D PAGE software package. The applications of these algorithms, embodied as the feature of the program, are explained in an accompanying article (R. D. Appel et al.; Electrophoresis 1997, 18, 2724-2734).

  15. Specifying residential retrofit packages for 30 % reductions in energy consumption in hot-humid climate zones

    Energy Technology Data Exchange (ETDEWEB)

    Burgett, J.M.; Chini, A.R.; Oppenheim, P. [University of Florida, 573 Rinker Hall, Newell Drive, Gainesville, FL 32611 (United States)

    2013-08-15

    The purpose of this research was to demonstrate the application of energy simulation as an effective tool for specifying cost-effective residential retrofit packages that will reduce energy consumption by 30 %. Single-family homes in the hot-humid climate type of the Southeastern USA were used to demonstrate the application. US census data from both state and federal studies were used to create 12 computer simulation homes representing the most common characteristics of single-family houses specific to this area. Well-recognized energy efficiency measures (EEMs) were simulated to determine their cumulative energy reduction potential. Detailed cost estimates were created for cost-to-benefit analysis. For each of the 12 simulated homes, 4 packages of EEMs were created. The four packages provided home owners options for reducing their energy by 30 % along with the estimated up-front cost and simple payback periods. The simple payback period was used to determine how cost-effective a measure was. The packages are specific to a geographic area to provide a higher degree of confidence in the projected cost and energy savings. The study provides a generic methodology to create a similar 30 % energy reduction packages for other locations and a detailed description of a case study to serve as an example. The study also highlights the value that computer simulation models can have to develop energy efficiency packages cost-effectively and specific to home owner's location and housing type.

  16. Integrated software package for nuclear material safeguards in a MOX fuel fabrication facility

    International Nuclear Information System (INIS)

    Schreiber, H.J.; Piana, M.; Moussalli, G.; Saukkonen, H.

    2000-01-01

    Since computerized data processing was introduced to Safeguards at large bulk handling facilities, a large number of individual software applications have been developed for nuclear material Safeguards implementation. Facility inventory and flow data are provided in computerized format for performing stratification, sample size calculation and selection of samples for destructive and non-destructive assay. Data is collected from nuclear measurement systems running in attended, unattended mode and more recently from remote monitoring systems controlled. Data sets from various sources have to be evaluated for Safeguards purposes, such as raw data, processed data and conclusions drawn from data evaluation results. They are reported in computerized format at the International Atomic Energy Agency headquarters and feedback from the Agency's mainframe computer system is used to prepare and support Safeguards inspection activities. The integration of all such data originating from various sources cannot be ensured without the existence of a common data format and a database system. This paper describes the fundamental relations between data streams, individual data processing tools, data evaluation results and requirements for an integrated software solution to facilitate nuclear material Safeguards at a bulk handling facility. The paper also explains the basis for designing a software package to manage data streams from various data sources and for incorporating diverse data processing tools that until now have been used independently from each other and under different computer operating systems. (author)

  17. LipiDex: An Integrated Software Package for High-Confidence Lipid Identification.

    Science.gov (United States)

    Hutchins, Paul D; Russell, Jason D; Coon, Joshua J

    2018-04-17

    State-of-the-art proteomics software routinely quantifies thousands of peptides per experiment with minimal need for manual validation or processing of data. For the emerging field of discovery lipidomics via liquid chromatography-tandem mass spectrometry (LC-MS/MS), comparably mature informatics tools do not exist. Here, we introduce LipiDex, a freely available software suite that unifies and automates all stages of lipid identification, reducing hands-on processing time from hours to minutes for even the most expansive datasets. LipiDex utilizes flexible in silico fragmentation templates and lipid-optimized MS/MS spectral matching routines to confidently identify and track hundreds of lipid species and unknown compounds from diverse sample matrices. Unique spectral and chromatographic peak purity algorithms accurately quantify co-isolation and co-elution of isobaric lipids, generating identifications that match the structural resolution afforded by the LC-MS/MS experiment. During final data filtering, ionization artifacts are removed to significantly reduce dataset redundancy. LipiDex interfaces with several LC-MS/MS software packages, enabling robust lipid identification to be readily incorporated into pre-existing data workflows. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. GENES - a software package for analysis in experimental statistics and quantitative genetics

    Directory of Open Access Journals (Sweden)

    Cosme Damião Cruz

    2013-06-01

    Full Text Available GENES is a software package used for data analysis and processing with different biometricmodels and is essential in genetic studies applied to plant and animal breeding. It allows parameterestimation to analyze biologicalphenomena and is fundamental for the decision-making process andpredictions of success and viability of selection strategies. The program can be downloaded from theInternet (http://www.ufv.br/dbg/genes/genes.htm orhttp://www.ufv.br/dbg/biodata.htm and is available inPortuguese, English and Spanish. Specific literature (http://www.livraria.ufv.br/ and a set of sample filesare also provided, making GENES easy to use. The software is integrated into the programs MS Word, MSExcel and Paint, ensuring simplicity and effectiveness indata import and export ofresults, figures and data.It is also compatible with the free software R and Matlab, through the supply of useful scripts available forcomplementary analyses in different areas, including genome wide selection, prediction of breeding valuesand use of neural networks in genetic improvement.

  19. MAPPIX: A software package for off-line micro-pixe single particle aerosol analysis

    International Nuclear Information System (INIS)

    Ceccato, D.

    2009-01-01

    In the framework of a multiannual experiment performed at Baia Terra Nova, Antarctica, size-segregated aerosol samples were collected by using a 12-stage SDI impactor (Hillamo design). Approximately 2800 particles, belonging to the first four supermicrometric SDI stages - 8.39, 4.08, 2.68, 1.66 μm dynamic aerosol diameter cuts - were analyzed at the INFN-LNL micro-PIXE facility, a three lens Oxford Microprobe (OM) product, installed in the early nineties. Four regions on each of the 12 sub-samples were measured; 60 aerosol particles were detected on average in each of the analyzed regions. The off-line single aerosol particle (SAP) analysis of such big amount of data required software that is able to rapidly handle the acquired data, with a simple and fast area selection procedure; the subsequent automated PIXE spectra analysis with a specialized code was also needed. The MAPPIX 2.0 software was designed to make easier and faster the user jobs during the SAP analysis. The package is composed of two separate routines: the first one is devoted to data format conversion (OM-LMF file format to MAPPIX format), while the second one is devoted to micro-PIXE maps graphical presentation and aerosol particle selection procedure. The MAPPIX data format and software features will be discussed; a short report of the speed performances will be presented.

  20. Package

    Directory of Open Access Journals (Sweden)

    Arsić Zoran

    2013-01-01

    Full Text Available It is duty of the seller to pack the goods in a manner which assures their safe arrival and enables their handling in transit and at the place of destination. The problem of packing is relevant in two main respects. First of all the buyer is in certain circumstances entitled to refuse acceptance of the goods if they are not properly packed. Second, the package is relevant to calculation of price and freight based on weight. In the case of export trade, the package should conform to the legislation in the country of destination. The impact of package on environment is regulated by environment protection regulation of Republic if Serbia.

  1. PCG: A software package for the iterative solution of linear systems on scalar, vector and parallel computers

    Energy Technology Data Exchange (ETDEWEB)

    Joubert, W. [Los Alamos National Lab., NM (United States); Carey, G.F. [Univ. of Texas, Austin, TX (United States)

    1994-12-31

    A great need exists for high performance numerical software libraries transportable across parallel machines. This talk concerns the PCG package, which solves systems of linear equations by iterative methods on parallel computers. The features of the package are discussed, as well as techniques used to obtain high performance as well as transportability across architectures. Representative numerical results are presented for several machines including the Connection Machine CM-5, Intel Paragon and Cray T3D parallel computers.

  2. DISPL: a software package for one and two spatially dimensioned kinetics-diffusion problems. [FORTRAN for IBM computers

    Energy Technology Data Exchange (ETDEWEB)

    Leaf, G K; Minkoff, M; Byrne, G D; Sorensen, D; Bleakney, T; Saltzman, J

    1978-11-01

    DISPL is a software package for solving some second-order nonlinear systems of partial differential equations including parabolic, elliptic, hyperbolic, and some mixed types such as parabolic--elliptic equations. Fairly general nonlinear boundary conditions are allowed as well as interface conditions for problems in an inhomogeneous media. The spatial domain is one- or two-dimensional with Cartesian, cylindrical, or spherical (in one dimension only) geometry. The numerical method is based on the use of Galerkin's procedure combined with the use of B-splines in order to reduce the system of PDE's to a system of ODE's. The latter system is then solved with a sophisticated ODE software package. Software features include extensive dump/restart facilities, free format input, moderate printed output capability, dynamic storage allocation, and three graphics packages. 17 figures, 9 tables.

  3. Quantitation of magnetic resonance spectroscopy signals: the jMRUI software package

    International Nuclear Information System (INIS)

    Stefan, D; Andrasescu, A; Cesare, F Di; Popa, E; Lazariev, A; Graveron-Demilly, D; Vescovo, E; Williams, S; Strbak, O; Starcuk, Z; Cabanas, M; Van Ormondt, D

    2009-01-01

    The software package jMRUI with Java-based graphical user interface enables user-friendly time-domain analysis of magnetic resonance spectroscopy (MRS) and spectroscopic imaging (MRSI) and HRMAS-NMR signals. Version 3.x has been distributed in more than 1200 groups or hospitals worldwide. The new version 4.x is a plug-in platform enabling the users to add their own algorithms. Moreover, it offers new functionalities compared to versions 3.x. The quantum-mechanical simulator based on NMR-SCOPE, the quantitation algorithm QUEST and the main MRSI functionalities are described. Quantitation results of signals obtained in vivo from a mouse and a human brain are given

  4. VISUAL: a software package for plotting data in the RADHEAT-V4 code system

    International Nuclear Information System (INIS)

    Sasaki, Toshihiko; Yamano, Naoki

    1984-03-01

    In this report, the features, the capabilities and the constitution of the VISUAL Software Package are presented. The one of the features is that the VISUAL provides a versatile graphic display tool to plot a wide variety of data of the RADHEAT-V4 code system. And the other is to enable a user to handle easily the executing data in the Conversational Management Mode named ''CMM''. The program adopts the adjustable dimension system to increase its flexibility. VISUAL generates two-dimensional drawing, contour line map and three dimensional drawing on TSS (Time Sharing System) digital graphic equipment, NLP (Nihongo Laser Printer) or COM(Computer Output Microfilm). It is easily possible to display the calculated and experimental data in a DATA-POOL by using these functions. The purpose of this report is to describe sufficient information to enable a user to use VISUAL profitabily. (author)

  5. Software package to automate the design and production of translucent building structures made of pvc

    Directory of Open Access Journals (Sweden)

    Petrova Irina Yur’evna

    2016-08-01

    Full Text Available The article describes the features of the design and production of translucent building structures made of PVC. The analysis of the automation systems of this process currently existing on the market is carried out, their advantages and disadvantages are identified. Basing on this analysis, a set of requirements for automation systems for the design and production of translucent building structures made of PVC is formulated; the basic entities are involved in those business processes. The necessary functions for the main application and for dealers’ application are specified. The main application is based on technological platform 1C: Enterprise 8.2. The dealers’ module is .NET application and is developed with the use of Microsoft Visual Studio and Microsoft SQL Server because these software products have client versions free for end users (.NET Framework 4.0 Client Profile and Microsoft SQL Server 2008 Express. The features of the developed software complex implementation are described; the relevant charts are given. The scheme of system deployment and protocols of data exchange between 1C server, 1C client and dealer is presented. Also the functions supported by 1C module and .NET module are described. The article describes the content of class library developed for .NET module. The specification of integration of the two applications in a single software package is given. The features of the GUI organization are described; the corresponding screenshots are given. The possible ways of further development of the described software complex are presented and a conclusion about its competitiveness and expediency of new researches is made.

  6. Highly-optimized TWSM software package for seismic diffraction modeling adapted for GPU-cluster

    Science.gov (United States)

    Zyatkov, Nikolay; Ayzenberg, Alena; Aizenberg, Arkady

    2015-04-01

    Oil producing companies concern to increase resolution capability of seismic data for complex oil-and-gas bearing deposits connected with salt domes, basalt traps, reefs, lenses, etc. Known methods of seismic wave theory define shape of hydrocarbon accumulation with nonsufficient resolution, since they do not account for multiple diffractions explicitly. We elaborate alternative seismic wave theory in terms of operators of propagation in layers and reflection-transmission at curved interfaces. Approximation of this theory is realized in the seismic frequency range as the Tip-Wave Superposition Method (TWSM). TWSM based on the operator theory allows to evaluate of wavefield in bounded domains/layers with geometrical shadow zones (in nature it can be: salt domes, basalt traps, reefs, lenses, etc.) accounting for so-called cascade diffraction. Cascade diffraction includes edge waves from sharp edges, creeping waves near concave parts of interfaces, waves of the whispering galleries near convex parts of interfaces, etc. The basic algorithm of TWSM package is based on multiplication of large-size matrices (make hundreds of terabytes in size). We use advanced information technologies for effective realization of numerical procedures of the TWSM. In particular, we actively use NVIDIA CUDA technology and GPU accelerators allowing to significantly improve the performance of the TWSM software package, that is important in using it for direct and inverse problems. The accuracy, stability and efficiency of the algorithm are justified by numerical examples with curved interfaces. TWSM package and its separate components can be used in different modeling tasks such as planning of acquisition systems, physical interpretation of laboratory modeling, modeling of individual waves of different types and in some inverse tasks such as imaging in case of laterally inhomogeneous overburden, AVO inversion.

  7. SMOG 2: A Versatile Software Package for Generating Structure-Based Models.

    Science.gov (United States)

    Noel, Jeffrey K; Levi, Mariana; Raghunathan, Mohit; Lammert, Heiko; Hayes, Ryan L; Onuchic, José N; Whitford, Paul C

    2016-03-01

    Molecular dynamics simulations with coarse-grained or simplified Hamiltonians have proven to be an effective means of capturing the functionally important long-time and large-length scale motions of proteins and RNAs. Originally developed in the context of protein folding, structure-based models (SBMs) have since been extended to probe a diverse range of biomolecular processes, spanning from protein and RNA folding to functional transitions in molecular machines. The hallmark feature of a structure-based model is that part, or all, of the potential energy function is defined by a known structure. Within this general class of models, there exist many possible variations in resolution and energetic composition. SMOG 2 is a downloadable software package that reads user-designated structural information and user-defined energy definitions, in order to produce the files necessary to use SBMs with high performance molecular dynamics packages: GROMACS and NAMD. SMOG 2 is bundled with XML-formatted template files that define commonly used SBMs, and it can process template files that are altered according to the needs of each user. This computational infrastructure also allows for experimental or bioinformatics-derived restraints or novel structural features to be included, e.g. novel ligands, prosthetic groups and post-translational/transcriptional modifications. The code and user guide can be downloaded at http://smog-server.org/smog2.

  8. SMOG 2: A Versatile Software Package for Generating Structure-Based Models.

    Directory of Open Access Journals (Sweden)

    Jeffrey K Noel

    2016-03-01

    Full Text Available Molecular dynamics simulations with coarse-grained or simplified Hamiltonians have proven to be an effective means of capturing the functionally important long-time and large-length scale motions of proteins and RNAs. Originally developed in the context of protein folding, structure-based models (SBMs have since been extended to probe a diverse range of biomolecular processes, spanning from protein and RNA folding to functional transitions in molecular machines. The hallmark feature of a structure-based model is that part, or all, of the potential energy function is defined by a known structure. Within this general class of models, there exist many possible variations in resolution and energetic composition. SMOG 2 is a downloadable software package that reads user-designated structural information and user-defined energy definitions, in order to produce the files necessary to use SBMs with high performance molecular dynamics packages: GROMACS and NAMD. SMOG 2 is bundled with XML-formatted template files that define commonly used SBMs, and it can process template files that are altered according to the needs of each user. This computational infrastructure also allows for experimental or bioinformatics-derived restraints or novel structural features to be included, e.g. novel ligands, prosthetic groups and post-translational/transcriptional modifications. The code and user guide can be downloaded at http://smog-server.org/smog2.

  9. Development of the processing software package for RPV neutron fluence determination methodology

    International Nuclear Information System (INIS)

    Belousov, S.; Kirilova, K.; Ilieva, K.

    2001-01-01

    According to the INRNE methodology the neutron transport calculation is carried out by two steps. At the first step reactor core eigenvalue calculation is performed. This calculation is used for determination of the fixed source for the next step calculation of neutron transport from the reactor core to the RPV. Both calculation steps are performed by state of the art and tested codes. The interface software package DOSRC developed at INRNE is used as a link between these two calculations. The package transforms reactor core calculation results to neutron source input data in format appropriate for the neutron transport codes (DORT, TORT and ASYNT) based on the discrete ordinates method. These codes are applied for calculation of the RPV neutron flux and its responses - induced activity, radiation damage, neutron fluence etc. Fore more precise estimation of the neutron fluence, the INRNE methodology has been supplemented by the next improvements: - implementation of more advanced codes (PYTHIA/DERAB) for neutron-physics parameter calculations; - more detailed neutron source presentation; - verification of neutron fluence by statistically treated experimental data. (author)

  10. A software package for evaluating the performance of a star sensor operation

    Science.gov (United States)

    Sarpotdar, Mayuresh; Mathew, Joice; Sreejith, A. G.; Nirmal, K.; Ambily, S.; Prakash, Ajin; Safonova, Margarita; Murthy, Jayant

    2017-02-01

    We have developed a low-cost off-the-shelf component star sensor ( StarSense) for use in minisatellites and CubeSats to determine the attitude of a satellite in orbit. StarSense is an imaging camera with a limiting magnitude of 6.5, which extracts information from star patterns it records in the images. The star sensor implements a centroiding algorithm to find centroids of the stars in the image, a Geometric Voting algorithm for star pattern identification, and a QUEST algorithm for attitude quaternion calculation. Here, we describe the software package to evaluate the performance of these algorithms as a star sensor single operating system. We simulate the ideal case where sky background and instrument errors are omitted, and a more realistic case where noise and camera parameters are added to the simulated images. We evaluate such performance parameters of the algorithms as attitude accuracy, calculation time, required memory, star catalog size, sky coverage, etc., and estimate the errors introduced by each algorithm. This software package is written for use in MATLAB. The testing is parametrized for different hardware parameters, such as the focal length of the imaging setup, the field of view (FOV) of the camera, angle measurement accuracy, distortion effects, etc., and therefore, can be applied to evaluate the performance of such algorithms in any star sensor. For its hardware implementation on our StarSense, we are currently porting the codes in form of functions written in C. This is done keeping in view its easy implementation on any star sensor electronics hardware.

  11. Advances in the development of the PIXEKLM-TPI software package

    International Nuclear Information System (INIS)

    Uzonyi, I.; Szabo, Gy.

    2005-01-01

    Complete text of publication follows. During the past decade great effort has been devoted to the developments of various local analytical methods which are capable to analyze small volumes of a sample (in the range of some μm 3 ) by high lateral and/or depth resolution. Among the Ion Beam Analytical (IBA) methods, Particle Induced X-Ray Fluorescence Emission (PIXE) analysis has been used for qualitative elemental imaging for a long time. Nevertheless, production of quantitative images is still a challenging and unresolved problem in general. Ryan and his co-workers were the first who developed a software package (GeoPIXE) for on-line quantitative mapping which is capable to analyze especially thick samples. Some years ago we also started to develop quantitative PIXE imaging software and suggested a different approach for the compensation of matrix effects and sample thickness. It is based on the rapid matrix transform method called Dynamic Analysis which directly converts the spectrum vector (S) into the concentration vector (C) in terms of the matrix Γ. We modified the earlier version of the PIXEKLM program in order to calculate the Γ matrix for materials of any thickness. Furthermore, we have developed a windows-based program (True PIXE Imaging, TPI) which calculates elemental distributions on a pixel by pixel basis and creates so called elemental images from them in bit map form using colour bars. The basic part of the new program package was published in 2005. During the past year much efforts has been devoted to develop various new options such as visualization of spectrum components in order to make the program more user-friendly and applicable. In the figure below the decomposed PIXE spectrum of an industrial material is visualized. (author)

  12. ImagePy: an open-source, Python-based and platform-independent software package for boimage analysis.

    Science.gov (United States)

    Wang, Anliang; Yan, Xiaolong; Wei, Zhijun

    2018-04-27

    This note presents the design of a scalable software package named ImagePy for analysing biological images. Our contribution is concentrated on facilitating extensibility and interoperability of the software through decoupling the data model from the user interface. Especially with assistance from the Python ecosystem, this software framework makes modern computer algorithms easier to be applied in bioimage analysis. ImagePy is free and open source software, with documentation and code available at https://github.com/Image-Py/imagepy under the BSD license. It has been tested on the Windows, Mac and Linux operating systems. wzjdlut@dlut.edu.cn or yxdragon@imagepy.org.

  13. INSPECT: A graphical user interface software package for IDARC-2D

    Science.gov (United States)

    AlHamaydeh, Mohammad; Najib, Mohamad; Alawnah, Sameer

    Modern day Performance-Based Earthquake Engineering (PBEE) pivots about nonlinear analysis and its feasibility. IDARC-2D is a widely used and accepted software for nonlinear analysis; it possesses many attractive features and capabilities. However, it is operated from the command prompt in the DOS/Unix systems and requires elaborate text-based input files creation by the user. To complement and facilitate the use of IDARC-2D, a pre-processing GUI software package (INSPECT) is introduced herein. INSPECT is created in the C# environment and utilizes the .NET libraries and SQLite database. Extensive testing and verification demonstrated successful and high-fidelity re-creation of several existing IDARC-2D input files. Its design and built-in features aim at expediting, simplifying and assisting in the modeling process. Moreover, this practical aid enhances the reliability of the results and improves accuracy by reducing and/or eliminating many potential and common input mistakes. Such benefits would be appreciated by novice and veteran IDARC-2D users alike.

  14. Mirion--a software package for automatic processing of mass spectrometric images.

    Science.gov (United States)

    Paschke, C; Leisner, A; Hester, A; Maass, K; Guenther, S; Bouschen, W; Spengler, B

    2013-08-01

    Mass spectrometric imaging (MSI) techniques are of growing interest for the Life Sciences. In recent years, the development of new instruments employing ion sources that are tailored for spatial scanning allowed the acquisition of large data sets. A subsequent data processing, however, is still a bottleneck in the analytical process, as a manual data interpretation is impossible within a reasonable time frame. The transformation of mass spectrometric data into spatial distribution images of detected compounds turned out to be the most appropriate method to visualize the results of such scans, as humans are able to interpret images faster and easier than plain numbers. Image generation, thus, is a time-consuming and complex yet very efficient task. The free software package "Mirion," presented in this paper, allows the handling and analysis of data sets acquired by mass spectrometry imaging. Mirion can be used for image processing of MSI data obtained from many different sources, as it uses the HUPO-PSI-based standard data format imzML, which is implemented in the proprietary software of most of the mass spectrometer companies. Different graphical representations of the recorded data are available. Furthermore, automatic calculation and overlay of mass spectrometric images promotes direct comparison of different analytes for data evaluation. The program also includes tools for image processing and image analysis.

  15. Software analyzes feasibility of saw kerf reduction for hardwood mills

    Science.gov (United States)

    Philip H. Steele

    2005-01-01

    Reductions in saw kerf on head rigs and resaws can dramatically increase lumber recovery in hardwood sawmills. Research has shown that lumber sawing variation reduction will increase lumber recovery above that obtained solely from kerf reduction. Reductions in sawing machine kerf or variation always come at some cost in both capital and variable costs. Determining...

  16. Calculation of chemical equilibrium between aqueous solution and minerals: the EQ3/6 software package

    International Nuclear Information System (INIS)

    Wolery, T.J.

    1979-01-01

    The newly developed EQ/36 software package computes equilibrium models of aqueous geochemical systems. The package contains two principal programs: EQ3 performs distribution-of-species calculations for natural water compositions; EQ6 uses the results of EQ3 to predict the consequences of heating and cooling aqueous solutions and of irreversible reaction in rock--water systems. The programs are valuable for studying such phenomena as the formation of ore bodies, scaling and plugging in geothermal development, and the long-term disposal of nuclear waste. EQ3 and EQ6 are compared with such well-known geochemical codes as SOLMNEQ, WATEQ, REDEQL, MINEQL, and PATHI. The data base allows calculations in the temperature interval 0 to 350 0 C, at either 1 atm-steam saturation pressures or a constant 500 bars. The activity coefficient approximations for aqueous solutes limit modeling to solutions of ionic strength less than about one molal. The mathematical derivations and numerical techniques used in EQ6 are presented in detail. The program uses the Newton--Raphson method to solve the governing equations of chemical equilibrium for a system of specified elemental composition at fixed temperature and pressure. Convergence is aided by optimizing starting estimates and by under-relaxation techniques. The minerals present in the stable phase assemblage are found by several empirical methods. Reaction path models may be generated by using this approach in conjunction with finite differences. This method is analogous to applying high-order predictor--corrector methods to integrate a corresponding set of ordinary differential equations, but avoids propagation of error (drift). 8 figures, 9 tables

  17. Sodium Reduction in US Households' Packaged Food and Beverage Purchases, 2000 to 2014.

    Science.gov (United States)

    Poti, Jennifer M; Dunford, Elizabeth K; Popkin, Barry M

    2017-07-01

    study, significant reductions in sodium from packaged food purchases were achieved in the past 15 years. Nonetheless, most US households had food and beverage purchases with excessive sodium density. Findings suggest that more concerted sodium reduction efforts are needed in the United States.

  18. ANALYSIS OF CELLULAR REACTION TO IFN-γ STIMULATION BY A SOFTWARE PACKAGE GeneExpressionAnalyser

    Directory of Open Access Journals (Sweden)

    A. V. Saetchnikov

    2014-01-01

    Full Text Available The software package GeneExpressionAnalyser for analysis of the DNA microarray experi-mental data has been developed. The algorithms of data analysis, differentially expressed genes and biological functions of the cell are described. The efficiency of the developed package is tested on the published experimental data devoted to the time-course research of the changes in the human cell un-der the influence of IFN-γ on melanoma. The developed software has a number of advantages over the existing software: it is free, has a simple and intuitive graphical interface, allows to analyze different types of DNA microarrays, contains a set of methods for complete data analysis and performs effec-tive gene annotation for a selected list of genes.

  19. A Versatile Software Package for Inter-subject Correlation Based Analyses of fMRI

    Directory of Open Access Journals (Sweden)

    Jukka-Pekka eKauppi

    2014-01-01

    Full Text Available In the inter-subject correlation (ISC based analysis of the functional magnetic resonance imaging (fMRI data, the extent of shared processing across subjects during the experiment is determined by calculating correlation coefficients between the fMRI time series of the subjects in the corresponding brain locations. This implies that ISC can be used to analyze fMRI data without explicitly modelling the stimulus and thus ISC is a potential method to analyze fMRI data acquired under complex naturalistic stimuli. Despite of the suitability of ISC based approach to analyze complex fMRI data, no generic software tools have been made available for this purpose, limiting a widespread use of ISC based analysis techniques among neuroimaging community. In this paper, we present a graphical user interface (GUI based software package, ISC Toolbox, implemented in Matlab for computing various ISC based analyses. Many advanced computations such as comparison of ISCs between different stimuli, time window ISC, and inter-subject phase synchronization are supported by the toolbox. The analyses are coupled with re-sampling based statistical inference. The ISC based analyses are data and computation intensive and the ISC toolbox is equipped with mechanisms to execute the parallel computations in a cluster environment automatically and with an automatic detection of the cluster environment in use. Currently, SGE-based (Oracle Grid Engine, Son of a Grid Engine or Open Grid Scheduler and Slurm environments are supported. In this paper, we present a detailed account on the methods behind the ISC Toolbox, the implementation of the toolbox and demonstrate the possible use of the toolbox by summarizing selected example applications. We also report the computation time experiments both using a single desktop computer and two grid environments demonstrating that parallelization effectively reduces the computing time. The ISC Toolbox is available in https://code.google.com/p/isc-toolbox/.

  20. A versatile software package for inter-subject correlation based analyses of fMRI.

    Science.gov (United States)

    Kauppi, Jukka-Pekka; Pajula, Juha; Tohka, Jussi

    2014-01-01

    In the inter-subject correlation (ISC) based analysis of the functional magnetic resonance imaging (fMRI) data, the extent of shared processing across subjects during the experiment is determined by calculating correlation coefficients between the fMRI time series of the subjects in the corresponding brain locations. This implies that ISC can be used to analyze fMRI data without explicitly modeling the stimulus and thus ISC is a potential method to analyze fMRI data acquired under complex naturalistic stimuli. Despite of the suitability of ISC based approach to analyze complex fMRI data, no generic software tools have been made available for this purpose, limiting a widespread use of ISC based analysis techniques among neuroimaging community. In this paper, we present a graphical user interface (GUI) based software package, ISC Toolbox, implemented in Matlab for computing various ISC based analyses. Many advanced computations such as comparison of ISCs between different stimuli, time window ISC, and inter-subject phase synchronization are supported by the toolbox. The analyses are coupled with re-sampling based statistical inference. The ISC based analyses are data and computation intensive and the ISC toolbox is equipped with mechanisms to execute the parallel computations in a cluster environment automatically and with an automatic detection of the cluster environment in use. Currently, SGE-based (Oracle Grid Engine, Son of a Grid Engine, or Open Grid Scheduler) and Slurm environments are supported. In this paper, we present a detailed account on the methods behind the ISC Toolbox, the implementation of the toolbox and demonstrate the possible use of the toolbox by summarizing selected example applications. We also report the computation time experiments both using a single desktop computer and two grid environments demonstrating that parallelization effectively reduces the computing time. The ISC Toolbox is available in https://code.google.com/p/isc-toolbox/

  1. Long-Haul Truck Sleeper Heating Load Reduction Package for Rest Period Idling

    Energy Technology Data Exchange (ETDEWEB)

    Lustbader, Jason Aaron; Kekelia, Bidzina; Tomerlin, Jeff; Kreutzer, Cory J.; Yeakel, Skip; Adelman, Steven; Luo, Zhiming; Zehme, John

    2016-04-05

    Annual fuel use for sleeper cab truck rest period idling is estimated at 667 million gallons in the United States, or 6.8% of long-haul truck fuel use. Truck idling during a rest period represents zero freight efficiency and is largely done to supply accessory power for climate conditioning of the cab. The National Renewable Energy Laboratory's CoolCab project aims to reduce heating, ventilating, and air conditioning (HVAC) loads and resulting fuel use from rest period idling by working closely with industry to design efficient long-haul truck thermal management systems while maintaining occupant comfort. Enhancing the thermal performance of cab/sleepers will enable smaller, lighter, and more cost-effective idle reduction solutions. In addition, if the fuel savings provide a one- to three-year payback period, fleet owners will be economically motivated to incorporate them. For candidate idle reduction technologies to be implemented by original equipment manufacturers and fleets, their effectiveness must be quantified. To address this need, several promising candidate technologies were evaluated through experimentation and modeling to determine their effectiveness in reducing rest period HVAC loads. Load reduction strategies were grouped into the focus areas of solar envelope, occupant environment, conductive pathways, and efficient equipment. Technologies in each of these focus areas were investigated in collaboration with industry partners. The most promising of these technologies were then combined with the goal of exceeding a 30% reduction in HVAC loads. These technologies included 'ultra-white' paint, advanced insulation, and advanced curtain design. Previous testing showed more than a 35.7% reduction in air conditioning loads. This paper describes the overall heat transfer coefficient testing of this advanced load reduction technology package that showed more than a 43% reduction in heating load. Adding an additional layer of advanced insulation

  2. Long-Haul Truck Sleeper Heating Load Reduction Package for Rest Period Idling: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Lustbader, Jason; Kekelia, Bidzina; Tomerlin, Jeff; Kreutzer, Cory; Adelman, Steve; Yeakel, Skip; Luo, Zhiming; Zehme, John

    2016-03-24

    Annual fuel use for sleeper cab truck rest period idling is estimated at 667 million gallons in the United States, or 6.8% of long-haul truck fuel use. Truck idling during a rest period represents zero freight efficiency and is largely done to supply accessory power for climate conditioning of the cab. The National Renewable Energy Laboratory's CoolCab project aims to reduce heating, ventilating, and air conditioning (HVAC) loads and resulting fuel use from rest period idling by working closely with industry to design efficient long-haul truck thermal management systems while maintaining occupant comfort. Enhancing the thermal performance of cab/sleepers will enable smaller, lighter, and more cost-effective idle reduction solutions. In addition, if the fuel savings provide a one- to three-year payback period, fleet owners will be economically motivated to incorporate them. For candidate idle reduction technologies to be implemented by original equipment manufacturers and fleets, their effectiveness must be quantified. To address this need, several promising candidate technologies were evaluated through experimentation and modeling to determine their effectiveness in reducing rest period HVAC loads. Load reduction strategies were grouped into the focus areas of solar envelope, occupant environment, conductive pathways, and efficient equipment. Technologies in each of these focus areas were investigated in collaboration with industry partners. The most promising of these technologies were then combined with the goal of exceeding a 30% reduction in HVAC loads. These technologies included 'ultra-white' paint, advanced insulation, and advanced curtain design. Previous testing showed more than a 35.7% reduction in air conditioning loads. This paper describes the overall heat transfer coefficient testing of this advanced load reduction technology package that showed more than a 43% reduction in heating load. Adding an additional layer of advanced insulation

  3. Establishing the Common Community Physics Package by Transitioning the GFS Physics to a Collaborative Software Framework

    Science.gov (United States)

    Xue, L.; Firl, G.; Zhang, M.; Jimenez, P. A.; Gill, D.; Carson, L.; Bernardet, L.; Brown, T.; Dudhia, J.; Nance, L. B.; Stark, D. R.

    2017-12-01

    The Global Model Test Bed (GMTB) has been established to support the evolution of atmospheric physical parameterizations in NCEP global modeling applications. To accelerate the transition to the Next Generation Global Prediction System (NGGPS), a collaborative model development framework known as the Common Community Physics Package (CCPP) is created within the GMTB to facilitate engagement from the broad community on physics experimentation and development. A key component to this Research to Operation (R2O) software framework is the Interoperable Physics Driver (IPD) that hooks the physics parameterizations from one end to the dynamical cores on the other end with minimum implementation effort. To initiate the CCPP, scientists and engineers from the GMTB separated and refactored the GFS physics. This exercise demonstrated the process of creating IPD-compliant code and can serve as an example for other physics schemes to do the same and be considered for inclusion into the CCPP. Further benefits to this process include run-time physics suite configuration and considerably reduced effort for testing modifications to physics suites through GMTB's physics test harness. The implementation will be described and the preliminary results will be presented at the conference.

  4. Efficient Calculation of Exact Exchange Within the Quantum Espresso Software Package

    Science.gov (United States)

    Barnes, Taylor; Kurth, Thorsten; Carrier, Pierre; Wichmann, Nathan; Prendergast, David; Kent, Paul; Deslippe, Jack

    Accurate simulation of condensed matter at the nanoscale requires careful treatment of the exchange interaction between electrons. In the context of plane-wave DFT, these interactions are typically represented through the use of approximate functionals. Greater accuracy can often be obtained through the use of functionals that incorporate some fraction of exact exchange; however, evaluation of the exact exchange potential is often prohibitively expensive. We present an improved algorithm for the parallel computation of exact exchange in Quantum Espresso, an open-source software package for plane-wave DFT simulation. Through the use of aggressive load balancing and on-the-fly transformation of internal data structures, our code exhibits speedups of approximately an order of magnitude for practical calculations. Additional optimizations are presented targeting the many-core Intel Xeon-Phi ``Knights Landing'' architecture, which largely powers NERSC's new Cori system. We demonstrate the successful application of the code to difficult problems, including simulation of water at a platinum interface and computation of the X-ray absorption spectra of transition metal oxides.

  5. QUENCH: A software package for the determination of quenching curves in Liquid Scintillation counting.

    Science.gov (United States)

    Cassette, Philippe

    2016-03-01

    In Liquid Scintillation Counting (LSC), the scintillating source is part of the measurement system and its detection efficiency varies with the scintillator used, the vial and the volume and the chemistry of the sample. The detection efficiency is generally determined using a quenching curve, describing, for a specific radionuclide, the relationship between a quenching index given by the counter and the detection efficiency. A quenched set of LS standard sources are prepared by adding a quenching agent and the quenching index and detection efficiency are determined for each source. Then a simple formula is fitted to the experimental points to define the quenching curve function. The paper describes a software package specifically devoted to the determination of quenching curves with uncertainties. The experimental measurements are described by their quenching index and detection efficiency with uncertainties on both quantities. Random Gaussian fluctuations of these experimental measurements are sampled and a polynomial or logarithmic function is fitted on each fluctuation by χ(2) minimization. This Monte Carlo procedure is repeated many times and eventually the arithmetic mean and the experimental standard deviation of each parameter are calculated, together with the covariances between these parameters. Using these parameters, the detection efficiency, corresponding to an arbitrary quenching index within the measured range, can be calculated. The associated uncertainty is calculated with the law of propagation of variances, including the covariance terms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. MulRF: a software package for phylogenetic analysis using multi-copy gene trees.

    Science.gov (United States)

    Chaudhary, Ruchi; Fernández-Baca, David; Burleigh, John Gordon

    2015-02-01

    MulRF is a platform-independent software package for phylogenetic analysis using multi-copy gene trees. It seeks the species tree that minimizes the Robinson-Foulds (RF) distance to the input trees using a generalization of the RF distance to multi-labeled trees. The underlying generic tree distance measure and fast running time make MulRF useful for inferring phylogenies from large collections of gene trees, in which multiple evolutionary processes as well as phylogenetic error may contribute to gene tree discord. MulRF implements several features for customizing the species tree search and assessing the results, and it provides a user-friendly graphical user interface (GUI) with tree visualization. The species tree search is implemented in C++ and the GUI in Java Swing. MulRF's executable as well as sample datasets and manual are available at http://genome.cs.iastate.edu/CBL/MulRF/, and the source code is available at https://github.com/ruchiherself/MulRFRepo. ruchic@ufl.edu Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  7. EPILAB: a software package for studies on the prediction of epileptic seizures.

    Science.gov (United States)

    Teixeira, C A; Direito, B; Feldwisch-Drentrup, H; Valderrama, M; Costa, R P; Alvarado-Rojas, C; Nikolopoulos, S; Le Van Quyen, M; Timmer, J; Schelter, B; Dourado, A

    2011-09-15

    A Matlab®-based software package, EPILAB, was developed for supporting researchers in performing studies on the prediction of epileptic seizures. It provides an intuitive and convenient graphical user interface. Fundamental concepts that are crucial for epileptic seizure prediction studies were implemented. This includes, for example, the development and statistical validation of prediction methodologies in long-term continuous recordings. Seizure prediction is usually based on electroencephalography (EEG) and electrocardiography (ECG) signals. EPILAB is able to process both EEG and ECG data stored in different formats. More than 35 time and frequency domain measures (features) can be extracted based on univariate and multivariate data analysis. These features can be post-processed and used for prediction purposes. The predictions may be conducted based on optimized thresholds or by applying classifications methods such as artificial neural networks, cellular neuronal networks, and support vector machines. EPILAB proved to be an efficient tool for seizure prediction, and aims to be a way to communicate, evaluate, and compare results and data among the seizure prediction community. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. VIBA-LAB2: a virtual ion beam analysis laboratory software package incorporating elemental map simulations

    International Nuclear Information System (INIS)

    Zhou, S.J.; Orlic, I.; Sanchez, J.L.; Watt, F.

    1999-01-01

    The software package VIBA-lab1, which incorporates PIXE and RBS energy spectra simulation has now been extended to include the simulation of elemental maps from 3D structures. VIBA-lab1 allows the user to define a wide variety of experimental parameters, e.g. energy and species of incident ions, excitation and detection geometry, etc. When the relevant experimental parameters as well as target composition are defined, the program can then simulate the corresponding PIXE and RBS spectra. VIBA-LAB2 has been written with applications in nuclear microscopy in mind. A set of drag-and-drop tools has been incorporated to allow the user to define a three-dimensional sample object of mixed elemental composition. PIXE energy spectra simulations are then carried out on pixel-by-pixel basis and the corresponding intensity distributions or elemental maps can be computed. Several simulated intensity distributions for some 3D objects are demonstrated, and simulations obtained from a simple IC are compared with experimental results

  9. Implementation of New Process Models for Tailored Polymer Composite Structures into Processing Software Packages

    International Nuclear Information System (INIS)

    Nguyen, Ba Nghiep; Jin, Xiaoshi; Wang, Jin; Phelps, Jay; Tucker, Charles L. III; Kunc, Vlastimil; Bapanapalli, Satish K.; Smith, Mark T.

    2010-01-01

    This report describes the work conducted under the Cooperative Research and Development Agreement (CRADA) (Nr. 260) between the Pacific Northwest National Laboratory (PNNL) and Autodesk, Inc. to develop and implement process models for injection-molded long-fiber thermoplastics (LFTs) in processing software packages. The structure of this report is organized as follows. After the Introduction Section (Section 1), Section 2 summarizes the current fiber orientation models developed for injection-molded short-fiber thermoplastics (SFTs). Section 3 provides an assessment of these models to determine their capabilities and limitations, and the developments needed for injection-molded LFTs. Section 4 then focuses on the development of a new fiber orientation model for LFTs. This model is termed the anisotropic rotary diffusion - reduced strain closure (ARD-RSC) model as it explores the concept of anisotropic rotary diffusion to capture the fiber-fiber interaction in long-fiber suspensions and uses the reduced strain closure method of Wang et al. to slow down the orientation kinetics in concentrated suspensions. In contrast to fiber orientation modeling, before this project, no standard model was developed to predict the fiber length distribution in molded fiber composites. Section 5 is therefore devoted to the development of a fiber length attrition model in the mold. Sections 6 and 7 address the implementations of the models in AMI, and the conclusions drawn from this work is presented in Section 8.

  10. Pixelman: a multi-platform data acquisition and processing software package for Medipix2, Timepix and Medipix3 detectors

    International Nuclear Information System (INIS)

    Turecek, D; Holy, T; Jakubek, J; Pospisil, S; Vykydal, Z

    2011-01-01

    The semiconductor pixel detectors Medipix2, Timepix and Medipix3 (256x256 square pixels, 55x55 μm each) are superior imaging devices in terms of spatial resolution, linearity and dynamic range. This makes them suitable for various applications such as radiography, neutronography, micro-tomography and X-ray dynamic defectoscopy. In order to control and manage such complex measurements a multi-platform software package for acquisition and data processing with a Java graphical user interface has been developed. The functionality of the original version of Pixelman package has been upgraded and extended to include the new medipix devices. The software package can be run on Microsoft Windows, Linux and Mac OS X operating systems. The architecture is very flexible and the functionality can be extended by plugins in C++, Java or combinations of both. The software package may be used as a distributed acquisition system using computers with different operating systems over a local network or the Internet.

  11. Pixelman: a multi-platform data acquisition and processing software package for Medipix2, Timepix and Medipix3 detectors

    Energy Technology Data Exchange (ETDEWEB)

    Turecek, D; Holy, T; Jakubek, J; Pospisil, S; Vykydal, Z, E-mail: daniel.turecek@utef.cvut.cz [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 12800 Prague 2 (Czech Republic)

    2011-01-15

    The semiconductor pixel detectors Medipix2, Timepix and Medipix3 (256x256 square pixels, 55x55 {mu}m each) are superior imaging devices in terms of spatial resolution, linearity and dynamic range. This makes them suitable for various applications such as radiography, neutronography, micro-tomography and X-ray dynamic defectoscopy. In order to control and manage such complex measurements a multi-platform software package for acquisition and data processing with a Java graphical user interface has been developed. The functionality of the original version of Pixelman package has been upgraded and extended to include the new medipix devices. The software package can be run on Microsoft Windows, Linux and Mac OS X operating systems. The architecture is very flexible and the functionality can be extended by plugins in C++, Java or combinations of both. The software package may be used as a distributed acquisition system using computers with different operating systems over a local network or the Internet.

  12. Risk reduction using DDP (Defect Detection and Prevention): Software support and software applications

    Science.gov (United States)

    Feather, M. S.

    2001-01-01

    Risk assessment and mitigation is the focus of the Defect Detection and Prevention (DDP) process, which has been applied to spacecraft technology assessments and planning, both hardware and software. DDP's major elements and their relevance to core requirement engineering concerns are summarized. The accompanying research demonstration illustrates DDP's tool support, and further customizations for application to software.

  13. BioXTAS RAW, a software program for high-throughput automated small-angle X-ray scattering data reduction and preliminary analysis

    DEFF Research Database (Denmark)

    Nielsen, S.S.; Toft, K.N.; Snakenborg, Detlef

    2009-01-01

    A fully open source software program for automated two-dimensional and one-dimensional data reduction and preliminary analysis of isotropic small-angle X-ray scattering (SAXS) data is presented. The program is freely distributed, following the open-source philosophy, and does not rely on any...... commercial software packages. BioXTAS RAW is a fully automated program that, via an online feature, reads raw two-dimensional SAXS detector output files and processes and plots data as the data files are created during measurement sessions. The software handles all steps in the data reduction. This includes...... mask creation, radial averaging, error bar calculation, artifact removal, normalization and q calibration. Further data reduction such as background subtraction and absolute intensity scaling is fast and easy via the graphical user interface. BioXTAS RAW also provides preliminary analysis of one...

  14. QUENCH: A software package for the determination of quenching curves in Liquid Scintillation counting

    International Nuclear Information System (INIS)

    Cassette, Philippe

    2016-01-01

    In Liquid Scintillation Counting (LSC), the scintillating source is part of the measurement system and its detection efficiency varies with the scintillator used, the vial and the volume and the chemistry of the sample. The detection efficiency is generally determined using a quenching curve, describing, for a specific radionuclide, the relationship between a quenching index given by the counter and the detection efficiency. A quenched set of LS standard sources are prepared by adding a quenching agent and the quenching index and detection efficiency are determined for each source. Then a simple formula is fitted to the experimental points to define the quenching curve function. The paper describes a software package specifically devoted to the determination of quenching curves with uncertainties. The experimental measurements are described by their quenching index and detection efficiency with uncertainties on both quantities. Random Gaussian fluctuations of these experimental measurements are sampled and a polynomial or logarithmic function is fitted on each fluctuation by χ"2 minimization. This Monte Carlo procedure is repeated many times and eventually the arithmetic mean and the experimental standard deviation of each parameter are calculated, together with the covariances between these parameters. Using these parameters, the detection efficiency, corresponding to an arbitrary quenching index within the measured range, can be calculated. The associated uncertainty is calculated with the law of propagation of variances, including the covariance terms. - Highlights: • The program “QUENCH” is devoted to the interpolation of quenching curves in LSC. • Functions are fitted to experimental data with uncertainties in both quenching and efficiency. • The parameters of the fitting function and the associated covariance matrix are evaluated. • The detection efficiency and uncertainty corresponding to a given quenching index is calculated.

  15. The software package for solving problems of mathematical modeling of isothermal curing process

    Directory of Open Access Journals (Sweden)

    S. G. Tikhomirov

    2016-01-01

    Full Text Available Summary. On the basis of the general laws of sulfur vulcanization diene rubbers the principles of the effective cross-linking using a multi-component agents was discussed. It is noted that the description of the mechanism of action of the complex cross-linking systems are complicated by the diversity of interactions of components and the influence of each of them on the curing kinetics, leading to a variety technological complications of real technology and affects on the quality and technical and economic indicators of the production of rubber goods. Based on the known theoretical approaches the system analysis of isothermal curing process was performed. It included the integration of different techniques and methods into a single set of. During the analysis of the kinetics of vulcanization it was found that the formation of the spatial grid parameters vulcanizates depend on many factors, to assess which requires special mathematical and algorithmic support. As a result of the stratification of the object were identified the following major subsystems. A software package for solving direct and inverse kinetic problems isothermal curing process was developed. Information support “Isothermal vulcanization” is a set of applications of mathematical modeling of isothermal curing. It is intended for direct and inverse kinetic problems. When solving the problem of clarifying the general scheme of chemical transformations used universal mechanism including secondary chemical reactions. Functional minimization algorithm with constraints on the unknown parameters was used for solving the inverse kinetic problem. Shows a flowchart of the program. An example of solving the inverse kinetic problem with the program was introduced. Dataware was implemented in the programming language C ++. Universal dependence to determine the initial concentration of the curing agent was applied . It allowing the use of a model with different properties of multicomponent

  16. MOlecular MAterials Property Prediction Package (MOMAP) 1.0: a software package for predicting the luminescent properties and mobility of organic functional materials

    Science.gov (United States)

    Niu, Yingli; Li, Wenqiang; Peng, Qian; Geng, Hua; Yi, Yuanping; Wang, Linjun; Nan, Guangjun; Wang, Dong; Shuai, Zhigang

    2018-04-01

    MOlecular MAterials Property Prediction Package (MOMAP) is a software toolkit for molecular materials property prediction. It focuses on luminescent properties and charge mobility properties. This article contains a brief descriptive introduction of key features, theoretical models and algorithms of the software, together with examples that illustrate the performance. First, we present the theoretical models and algorithms for molecular luminescent properties calculation, which includes the excited-state radiative/non-radiative decay rate constant and the optical spectra. Then, a multi-scale simulation approach and its algorithm for the molecular charge mobility are described. This approach is based on hopping model and combines with Kinetic Monte Carlo and molecular dynamics simulations, and it is especially applicable for describing a large category of organic semiconductors, whose inter-molecular electronic coupling is much smaller than intra-molecular charge reorganisation energy.

  17. A new version of Scilab software package for the study of dynamical systems

    Science.gov (United States)

    Bordeianu, C. C.; Felea, D.; Beşliu, C.; Jipa, Al.; Grossu, I. V.

    2009-11-01

    This work presents a new version of a software package for the study of chaotic flows, maps and fractals [1]. The codes were written using Scilab, a software package for numerical computations providing a powerful open computing environment for engineering and scientific applications. It was found that Scilab provides various functions for ordinary differential equation solving, Fast Fourier Transform, autocorrelation, and excellent 2D and 3D graphical capabilities. The chaotic behaviors of the nonlinear dynamics systems were analyzed using phase-space maps, autocorrelation functions, power spectra, Lyapunov exponents and Kolmogorov-Sinai entropy. Various well-known examples are implemented, with the capability of the users inserting their own ODE or iterative equations. New version program summaryProgram title: Chaos v2.0 Catalogue identifier: AEAP_v2_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEAP_v2_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 1275 No. of bytes in distributed program, including test data, etc.: 7135 Distribution format: tar.gz Programming language: Scilab 5.1.1. Scilab 5.1.1 should be installed before running the program. Information about the installation can be found at scilab.org/howto/install/windows" xlink:type="simple">http://wiki.scilab.org/howto/install/windows. Computer: PC-compatible running Scilab on MS Windows or Linux Operating system: Windows XP, Linux RAM: below 150 Megabytes Classification: 6.2 Catalogue identifier of previous version: AEAP_v1_0 Journal reference of previous version: Comput. Phys. Comm. 178 (2008) 788 Does the new version supersede the previous version?: Yes Nature of problem: Any physical model containing linear or nonlinear ordinary differential equations (ODE). Solution method: Numerical solving of

  18. EQ3/6, a software package for geochemical modeling of aqueous systems: Package overview and installation guide (Version 7.0)

    International Nuclear Information System (INIS)

    Wolery, T.J.

    1992-01-01

    EQ3/6 is a software package for geochemical modeling of aqueous systems. This report describes version 7.0. The major components of the package include: EQ3NR, a speciation-solubility code; EQ6, a reaction path code which models water/rock interaction or fluid mixing in either a pure reaction progress mode or a time mode; EQPT, a data file preprocessor, EQLIB, a supporting software library; and five supporting thermodynamic data files. The software deals with the concepts of thermodynamic equilibrium, thermodynamic disequilibrium, and reaction kinetics. The five supporting data files contain both standard state and activity coefficient-related data. Three support the use of the Davies or B equations for the activity coefficients; the other two support the use of Pitzer's equations. The temperature range of the thermodynamic data on the data files varies from 25 degree C only to 0--300 degree C. EQPT takes a formatted data file (a data0 file) and writes an unformatted near-equivalent called a datal file, which is actually the form read by EQ3NR and EQ6. EQ3NR is useful for analyzing groundwater chemistry data, calculating solubility limits, and determining whether certain reactions are in states of partial equilibrium or disequilibrium. It is also required to initialize an EQ6 calculation. EQ6 models the consequences of reacting an aqueous solution with a set of reactants which react irreversibly. It can also model fluid mixing and the consequences of changes in temperature. This code operates both in a pure reaction progress frame and in a time frame

  19. EQ3/6, a software package for geochemical modeling of aqueous systems: Package overview and installation guide (Version 7.0)

    Energy Technology Data Exchange (ETDEWEB)

    Wolery, T.J.

    1992-09-14

    EQ3/6 is a software package for geochemical modeling of aqueous systems. This report describes version 7.0. The major components of the package include: EQ3NR, a speciation-solubility code; EQ6, a reaction path code which models water/rock interaction or fluid mixing in either a pure reaction progress mode or a time mode; EQPT, a data file preprocessor, EQLIB, a supporting software library; and five supporting thermodynamic data files. The software deals with the concepts of thermodynamic equilibrium, thermodynamic disequilibrium, and reaction kinetics. The five supporting data files contain both standard state and activity coefficient-related data. Three support the use of the Davies or B-dot equations for the activity coefficients; the other two support the use of Pitzer`s equations. The temperature range of the thermodynamic data on the data files varies from 25{degree}C only to 0--300{degree}C. EQPT takes a formatted data file (a data0 file) and writes an unformatted near-equivalent called a datal file, which is actually the form read by EQ3NR and EQ6. EQ3NR is useful for analyzing groundwater chemistry data, calculating solubility limits, and determining whether certain reactions are in states of partial equilibrium or disequilibrium. It is also required to initialize an EQ6 calculation. EQ6 models the consequences of reacting an aqueous solution with a set of reactants which react irreversibly. It can also model fluid mixing and the consequences of changes in temperature. This code operates both in a pure reaction progress frame and in a time frame.

  20. Lung nodule volumetry: segmentation algorithms within the same software package cannot be used interchangeably

    DEFF Research Database (Denmark)

    Ashraf, Haseem; de Hoop, B; Shaker, S B

    2010-01-01

    We examined the reproducibility of lung nodule volumetry software that offers three different volumetry algorithms.......We examined the reproducibility of lung nodule volumetry software that offers three different volumetry algorithms....

  1. Parallelization of an existing high energy physics event reconstruction software package

    International Nuclear Information System (INIS)

    Schiefer, R.; Francis, D.

    1996-01-01

    Software parallelization allows an efficient use of available computing power to increase the performance of applications. In a case study the authors have investigated the parallelization of high energy physics event reconstruction software in terms of costs (effort, computing resource requirements), benefits (performance increase) and the feasibility of a systematic parallelization approach. Guidelines facilitating a parallel implementation are proposed for future software development

  2. Quantitative comparison and evaluation of two commercially available, two-dimensional electrophoresis image analysis software packages, Z3 and Melanie.

    Science.gov (United States)

    Raman, Babu; Cheung, Agnes; Marten, Mark R

    2002-07-01

    While a variety of software packages are available for analyzing two-dimensional electrophoresis (2-DE) gel images, no comparisons between these packages have been published, making it difficult for end users to determine which package would best meet their needs. The goal here was to develop a set of tests to quantitatively evaluate and then compare two software packages, Melanie 3.0 and Z3, in three of the fundamental steps involved in 2-DE image analysis: (i) spot detection, (ii) gel matching, and (iii) spot quantitation. To test spot detection capability, automatically detected protein spots were compared to manually counted, "real" protein spots. Spot matching efficiency was determined by comparing distorted (both geometrically and nongeometrically) gel images with undistorted original images, and quantitation tests were performed on artificial gels with spots of varying Gaussian volumes. In spot detection tests, Z3 performed better than Melanie 3.0 and required minimal user intervention to detect approximately 89% of the actual protein spots and relatively few extraneous spots. Results from gel matching tests depended on the type of image distortion used. For geometric distortions, Z3 performed better than Melanie 3.0, matching 99% of the spots, even for extreme distortions. For nongeometrical distortions, both Z3 and Melanie 3.0 required user intervention and performed comparably, matching 95% of the spots. In spot quantitation tests, both Z3 and Melanie 3.0 predicted spot volumes relatively well for spot ratios less than 1:6. For higher ratios, Melanie 3.0 did much better. In summary, results suggest Z3 requires less user intervention than Melanie 3.0, thus simplifying differential comparison of 2-DE gel images. Melanie 3.0, however, offers many more optional tools for image editing, spot detection, data reporting and statistical analysis than Z3. All image files used for these tests and updated information on the software are available on the internet

  3. Development and Evaluation of an Open-Source Software Package “CGITA” for Quantifying Tumor Heterogeneity with Molecular Images

    Directory of Open Access Journals (Sweden)

    Yu-Hua Dean Fang

    2014-01-01

    Full Text Available Background. The quantification of tumor heterogeneity with molecular images, by analyzing the local or global variation in the spatial arrangements of pixel intensity with texture analysis, possesses a great clinical potential for treatment planning and prognosis. To address the lack of available software for computing the tumor heterogeneity on the public domain, we develop a software package, namely, Chang-Gung Image Texture Analysis (CGITA toolbox, and provide it to the research community as a free, open-source project. Methods. With a user-friendly graphical interface, CGITA provides users with an easy way to compute more than seventy heterogeneity indices. To test and demonstrate the usefulness of CGITA, we used a small cohort of eighteen locally advanced oral cavity (ORC cancer patients treated with definitive radiotherapies. Results. In our case study of ORC data, we found that more than ten of the current implemented heterogeneity indices outperformed SUVmean for outcome prediction in the ROC analysis with a higher area under curve (AUC. Heterogeneity indices provide a better area under the curve up to 0.9 than the SUVmean and TLG (0.6 and 0.52, resp.. Conclusions. CGITA is a free and open-source software package to quantify tumor heterogeneity from molecular images. CGITA is available for free for academic use at http://code.google.com/p/cgita.

  4. Dose - a software package for the calculation of integrated exposure resulting from an accident in a nuclear power plant

    International Nuclear Information System (INIS)

    Doron, E.; Ohaion, H.; Asculai, E.

    1985-05-01

    A software package intended for the assessments of risks resulting from accidental release of radioactive materials from a nuclear power plant is presented. The models and the various programs based on them, are described. The work includes detailed operating instructions for the various programs, as well as instructions for the preparation of the necessary input data. Various options are described for additions and changes to the programs with the aim of extending their usefulness to more general cases from the aspects of meteorology and pollution sources. finally, a sample calculation that enables the user to test the proper functioning of the whole package, as well as his own proficiency in its use, is given. (author)

  5. SIMSAS - a window based software package for simulation and analysis of multiple small-angle scattering data

    International Nuclear Information System (INIS)

    Jayaswal, B.; Mazumder, S.

    1998-09-01

    Small-angle scattering data from strong scattering systems, e.g. porous materials, cannot be analysed invoking single scattering approximation as specimen needed to replicate the bulk matrix in essential properties are too thick to validate the approximation. The presence of multiple scattering is indicated by invalidity of the functional invariance property of the observed scattering profile with variation of sample thickness and/or wave length of the probing radiation. This article delineates how non accounting of multiple scattering affects the results of analysis and then how to correct the data for its effect. It deals with an algorithm to extract single scattering profile from small-angle scattering data affected by multiple scattering. The algorithm can process the scattering data and deduce single scattering profile in absolute scale. A software package, SIMSAS, is introduced for executing this inversion step. This package is useful both to simulate and to analyse multiple small-angle scattering data. (author)

  6. Guidelines for the verification and validation of expert system software and conventional software: Volume 5, Rationale and description of verification and validation guideline packages and procedures. Final report

    International Nuclear Information System (INIS)

    Miller, L.A.; Hayes, J.E.; Mirsky, S.M.

    1995-05-01

    This report is the fifth volume in a series of reports describing the results of the Expert System Verification and Validation (V ampersand V) project which is jointly funded by US NRC and EPRI toward formulating guidelines for V ampersand V of expert systems for use in nuclear power applications. This report provides the rationale for and description of those guidelines. The actual guidelines themselves (and the accompanying 11 step by step Procedures) are presented in Volume 7, User's Manual. Three factors determine what V ampersand V is needed: (1) the stage, of the development life cycle (requirements, design, or implementation), (2) whether the overall system or a specialized component needs be tested (knowledge base component, inference engine or other highly reusable element, or a component involving conventional software), and (3) the stringency of V ampersand V that is needed (as judged from an assessment of the system's complexity and the requirement for its integrity to form three Classes). A V ampersand V guideline package is provided for each of the combinations of these three variables. The package specifies the V ampersand V methods recommended and the order in which they should be administered, the assurances each method provides, the qualifications needed by the V ampersand V team to employ each Particular method, the degree to which the methods should be applied, the performance measures that should be taken, and the decision criteria for accepting, conditionally accepting, or rejecting an evaluated system. In addition to the guideline packages, highly detailed step-by-step procedures are provided for 11 of the more important methods, to ensure that they Can be implemented correctly. The guidelines can apply to conventional procedural software systems as well as all kinds of AI systems

  7. Guidelines for the verification and validation of expert system software and conventional software: Rationale and description of V ampersand V guideline packages and procedures. Volume 5

    International Nuclear Information System (INIS)

    Mirsky, S.M.; Hayes, J.E.; Miller, L.A.

    1995-03-01

    This report is the fifth volume in a series of reports describing the results of the Expert System Verification C, and Validation (V ampersand V) project which is jointly funded by the U.S. Nuclear Regulatory Commission and the Electric Power Research Institute toward the objective of formulating Guidelines for the V ampersand V of expert systems for use in nuclear power applications. This report provides the rationale for and description of those guidelines. The actual guidelines themselves are presented in Volume 7, open-quotes User's Manual.close quotes Three factors determine what V ampersand V is needed: (1) the stage of the development life cycle (requirements, design, or implementation); (2) whether the overall system or a specialized component needs to be tested (knowledge base component, inference engine or other highly reusable element, or a component involving conventional software); and (3) the stringency of V ampersand V that is needed (as judged from an assessment of the system's complexity and the requirement for its integrity to form three Classes). A V ampersand V Guideline package is provided for each of the combinations of these three variables. The package specifies the V ampersand V methods recommended and the order in which they should be administered, the assurances each method provides, the qualifications needed by the V ampersand V team to employ each particular method, the degree to which the methods should be applied, the performance measures that should be taken, and the decision criteria for accepting, conditionally accepting, or rejecting an evaluated system. In addition to the Guideline packages, highly detailed step-by-step procedures are provided for 11 of the more important methods, to ensure that they can be implemented correctly. The Guidelines can apply to conventional procedural software systems as well as all kinds of Al systems

  8. Evaluation of a software package for automated quality assessment of contrast detail images-comparison with subjective visual assessment

    International Nuclear Information System (INIS)

    Pascoal, A; Lawinski, C P; Honey, I; Blake, P

    2005-01-01

    Contrast detail analysis is commonly used to assess image quality (IQ) associated with diagnostic imaging systems. Applications include routine assessment of equipment performance and optimization studies. Most frequently, the evaluation of contrast detail images involves human observers visually detecting the threshold contrast detail combinations in the image. However, the subjective nature of human perception and the variations in the decision threshold pose limits to the minimum image quality variations detectable with reliability. Objective methods of assessment of image quality such as automated scoring have the potential to overcome the above limitations. A software package (CDRAD analyser) developed for automated scoring of images produced with the CDRAD test object was evaluated. Its performance to assess absolute and relative IQ was compared with that of an average observer. Results show that the software does not mimic the absolute performance of the average observer. The software proved more sensitive and was able to detect smaller low-contrast variations. The observer's performance was superior to the software's in the detection of smaller details. Both scoring methods showed frequent agreement in the detection of image quality variations resulting from changes in kVp and KERMA detector , which indicates the potential to use the software CDRAD analyser for assessment of relative IQ

  9. Analysing the Zenith Tropospheric Delay Estimates in On-line Precise Point Positioning (PPP) Services and PPP Software Packages.

    Science.gov (United States)

    Mendez Astudillo, Jorge; Lau, Lawrence; Tang, Yu-Ting; Moore, Terry

    2018-02-14

    As Global Navigation Satellite System (GNSS) signals travel through the troposphere, a tropospheric delay occurs due to a change in the refractive index of the medium. The Precise Point Positioning (PPP) technique can achieve centimeter/millimeter positioning accuracy with only one GNSS receiver. The Zenith Tropospheric Delay (ZTD) is estimated alongside with the position unknowns in PPP. Estimated ZTD can be very useful for meteorological applications, an example is the estimation of water vapor content in the atmosphere from the estimated ZTD. PPP is implemented with different algorithms and models in online services and software packages. In this study, a performance assessment with analysis of ZTD estimates from three PPP online services and three software packages is presented. The main contribution of this paper is to show the accuracy of ZTD estimation achievable in PPP. The analysis also provides the GNSS users and researchers the insight of the processing algorithm dependence and impact on PPP ZTD estimation. Observation data of eight whole days from a total of nine International GNSS Service (IGS) tracking stations spread in the northern hemisphere, the equatorial region and the southern hemisphere is used in this analysis. The PPP ZTD estimates are compared with the ZTD obtained from the IGS tropospheric product of the same days. The estimates of two of the three online PPP services show good agreement (<1 cm) with the IGS ZTD values at the northern and southern hemisphere stations. The results also show that the online PPP services perform better than the selected PPP software packages at all stations.

  10. Analysing the Zenith Tropospheric Delay Estimates in On-line Precise Point Positioning (PPP Services and PPP Software Packages

    Directory of Open Access Journals (Sweden)

    Jorge Mendez Astudillo

    2018-02-01

    Full Text Available As Global Navigation Satellite System (GNSS signals travel through the troposphere, a tropospheric delay occurs due to a change in the refractive index of the medium. The Precise Point Positioning (PPP technique can achieve centimeter/millimeter positioning accuracy with only one GNSS receiver. The Zenith Tropospheric Delay (ZTD is estimated alongside with the position unknowns in PPP. Estimated ZTD can be very useful for meteorological applications, an example is the estimation of water vapor content in the atmosphere from the estimated ZTD. PPP is implemented with different algorithms and models in online services and software packages. In this study, a performance assessment with analysis of ZTD estimates from three PPP online services and three software packages is presented. The main contribution of this paper is to show the accuracy of ZTD estimation achievable in PPP. The analysis also provides the GNSS users and researchers the insight of the processing algorithm dependence and impact on PPP ZTD estimation. Observation data of eight whole days from a total of nine International GNSS Service (IGS tracking stations spread in the northern hemisphere, the equatorial region and the southern hemisphere is used in this analysis. The PPP ZTD estimates are compared with the ZTD obtained from the IGS tropospheric product of the same days. The estimates of two of the three online PPP services show good agreement (<1 cm with the IGS ZTD values at the northern and southern hemisphere stations. The results also show that the online PPP services perform better than the selected PPP software packages at all stations.

  11. Company's Unusual Plan to Package Commercial Software with Business Textbooks Produces a Measure of Success.

    Science.gov (United States)

    Watkins, Beverly T.

    1992-01-01

    Course Technology Inc. has developed 10 products combining textbooks with commercial software for college accounting, business, computer science, and statistics courses. Five of the products use Lotus 1-2-3 spreadsheet software. The products have been positively received by teachers and students. (DB)

  12. Groundwater movement simulation by the software package PM5 for the Sviyaga river adjoining territory in the Republic of Tatarstan

    Science.gov (United States)

    Kosterina, E. A.; Isagadzhieva, Z. Sh

    2018-01-01

    Data of the ecological-hydrogeological fieldwork at the Predvolzhye region of the Republic of Tatarstan were analyzed. A geofiltration model of the Buinsk region area near the village of Stary Studenets in the territory of the Republic of Tatarstan was constructed by the PM5 software package. The model can be developed to become the basis for estimation of the groundwater reserves of the territory, modeling the operation of water intake wells, designing the location of water intake wells, and evaluation of their operational capabilities, and constructing sanitary protection zones.

  13. Evaluation of three state-of-the-art metabolite prediction software packages (Meteor, MetaSite, and StarDrop) through independent and synergistic use.

    Science.gov (United States)

    T'jollyn, H; Boussery, K; Mortishire-Smith, R J; Coe, K; De Boeck, B; Van Bocxlaer, J F; Mannens, G

    2011-11-01

    The aim of this study was to evaluate three different metabolite prediction software packages (Meteor, MetaSite, and StarDrop) with respect to their ability to predict loci of metabolism and suggest relative proportions of metabolites. A chemically diverse test set of 22 compounds, for which in vivo human mass balance studies and metabolic schemes were available, was used as basis for the evaluation. Each software package was provided with structures of the parent compounds, and predicted metabolites were compared with experimentally determined human metabolites. The evaluation consisted of two parts. First, different settings within each software package were investigated and the software was evaluated using those settings determined to give the best prediction. Second, the three different packages were combined using the optimized settings to see whether a synergistic effect concerning the overall metabolism prediction could be established. The performance of the software was scored for both sensitivity and precision, taking into account the capabilities/limitations of the particular software. Varying results were obtained for the individual packages. Meteor showed a general tendency toward overprediction, and this led to a relatively low precision (∼35%) but high sensitivity (∼70%). MetaSite and StarDrop both exhibited a sensitivity and precision of ∼50%. By combining predictions obtained with the different packages, we found that increased precision can be obtained. We conclude that the state-of-the-art individual metabolite prediction software has many advantageous features but needs refinement to obtain acceptable prediction profiles. Synergistic use of different software packages could prove useful.

  14. The arison data acquisition and elaboration software package running on Hewlett-Packard minicomputer

    International Nuclear Information System (INIS)

    Diamantidis, Z.

    1987-01-01

    In this article, a data acquisition and elaboration system is described consisting in a PCM data acquisition and a spectrum analyser system and their data elaboration package for reactor safety or other general purposes. Measurements on temperature, noise fluctuations of temperature or other noise analysis dynamics, pressure, etc. Time series and their conversion in engineering units and their statistical and frequency analysis is provided

  15. Reliability and accuracy of three imaging software packages used for 3D analysis of the upper airway on cone beam computed tomography images.

    Science.gov (United States)

    Chen, Hui; van Eijnatten, Maureen; Wolff, Jan; de Lange, Jan; van der Stelt, Paul F; Lobbezoo, Frank; Aarab, Ghizlane

    2017-08-01

    The aim of this study was to assess the reliability and accuracy of three different imaging software packages for three-dimensional analysis of the upper airway using CBCT images. To assess the reliability of the software packages, 15 NewTom 5G ® (QR Systems, Verona, Italy) CBCT data sets were randomly and retrospectively selected. Two observers measured the volume, minimum cross-sectional area and the length of the upper airway using Amira ® (Visage Imaging Inc., Carlsbad, CA), 3Diagnosys ® (3diemme, Cantu, Italy) and OnDemand3D ® (CyberMed, Seoul, Republic of Korea) software packages. The intra- and inter-observer reliability of the upper airway measurements were determined using intraclass correlation coefficients and Bland & Altman agreement tests. To assess the accuracy of the software packages, one NewTom 5G ® CBCT data set was used to print a three-dimensional anthropomorphic phantom with known dimensions to be used as the "gold standard". This phantom was subsequently scanned using a NewTom 5G ® scanner. Based on the CBCT data set of the phantom, one observer measured the volume, minimum cross-sectional area, and length of the upper airway using Amira ® , 3Diagnosys ® , and OnDemand3D ® , and compared these measurements with the gold standard. The intra- and inter-observer reliability of the measurements of the upper airway using the different software packages were excellent (intraclass correlation coefficient ≥0.75). There was excellent agreement between all three software packages in volume, minimum cross-sectional area and length measurements. All software packages underestimated the upper airway volume by -8.8% to -12.3%, the minimum cross-sectional area by -6.2% to -14.6%, and the length by -1.6% to -2.9%. All three software packages offered reliable volume, minimum cross-sectional area and length measurements of the upper airway. The length measurements of the upper airway were the most accurate results in all software packages. All

  16. The last developments of the airGR R-package, an open source software for rainfall-runoff modelling

    Science.gov (United States)

    Thirel, Guillaume; Delaigue, Olivier; Coron, Laurent; Perrin, Charles; Andréassian, Vazken

    2017-04-01

    and usability of this tool. References Coron L., Thirel G., Perrin C., Delaigue O., Andréassian V., airGR: a suite of lumped hydrological models in an R-package, Environmental Modelling and software, 2017, submitted. Coron, L., Perrin, C. and Michel, C. (2016). airGR: Suite of GR hydrological models for precipitation-runoff modelling. R package version 1.0.3. https://webgr.irstea.fr/airGR/?lang=en. R Core Team (2016). R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria. URL https://www.R-project.org/.

  17. GENIE: a software package for gene-gene interaction analysis in genetic association studies using multiple GPU or CPU cores

    Directory of Open Access Journals (Sweden)

    Wang Kai

    2011-05-01

    Full Text Available Abstract Background Gene-gene interaction in genetic association studies is computationally intensive when a large number of SNPs are involved. Most of the latest Central Processing Units (CPUs have multiple cores, whereas Graphics Processing Units (GPUs also have hundreds of cores and have been recently used to implement faster scientific software. However, currently there are no genetic analysis software packages that allow users to fully utilize the computing power of these multi-core devices for genetic interaction analysis for binary traits. Findings Here we present a novel software package GENIE, which utilizes the power of multiple GPU or CPU processor cores to parallelize the interaction analysis. GENIE reads an entire genetic association study dataset into memory and partitions the dataset into fragments with non-overlapping sets of SNPs. For each fragment, GENIE analyzes: 1 the interaction of SNPs within it in parallel, and 2 the interaction between the SNPs of the current fragment and other fragments in parallel. We tested GENIE on a large-scale candidate gene study on high-density lipoprotein cholesterol. Using an NVIDIA Tesla C1060 graphics card, the GPU mode of GENIE achieves a speedup of 27 times over its single-core CPU mode run. Conclusions GENIE is open-source, economical, user-friendly, and scalable. Since the computing power and memory capacity of graphics cards are increasing rapidly while their cost is going down, we anticipate that GENIE will achieve greater speedups with faster GPU cards. Documentation, source code, and precompiled binaries can be downloaded from http://www.cceb.upenn.edu/~mli/software/GENIE/.

  18. The consequences of a new software package for the quantification of gated-SPECT myocardial perfusion studies

    International Nuclear Information System (INIS)

    Veen, Berlinda J. van der; Dibbets-Schneider, Petra; Stokkel, Marcel P.M.; Scholte, Arthur J.

    2010-01-01

    Semiquantitative analysis of myocardial perfusion scintigraphy (MPS) has reduced inter- and intraobserver variability, and enables researchers to compare parameters in the same patient over time, or between groups of patients. There are several software packages available that are designed to process MPS data and quantify parameters. In this study the performances of two systems, quantitative gated SPECT (QGS) and 4D-MSPECT, in the processing of clinical patient data and phantom data were compared. The clinical MPS data of 148 consecutive patients were analysed using QGS and 4D-MSPECT to determine the end-diastolic volume, end-systolic volume and left ventricular ejection fraction. Patients were divided into groups based on gender, body mass index, heart size, stressor type and defect type. The AGATE dynamic heart phantom was used to provide reference values for the left ventricular ejection fraction. Although the correlations were excellent (correlation coefficients 0.886 to 0.980) for all parameters, significant differences (p < 0.001) were found between the systems. Bland-Altman plots indicated that 4D-MSPECT provided overall higher values of all parameters than QGS. These differences between the systems were not significant in patients with a small heart (end-diastolic volume <70 ml). Other clinical factors had no direct influence on the relationship. Additionally, the phantom data indicated good linear responses of both systems. The discrepancies between these software packages were clinically relevant, and influenced by heart size. The possibility of such discrepancies should be taken into account when a new quantitative software system is introduced, or when multiple software systems are used in the same institution. (orig.)

  19. A menu-driven software package of Bayesian nonparametric (and parametric) mixed models for regression analysis and density estimation.

    Science.gov (United States)

    Karabatsos, George

    2017-02-01

    Most of applied statistics involves regression analysis of data. In practice, it is important to specify a regression model that has minimal assumptions which are not violated by data, to ensure that statistical inferences from the model are informative and not misleading. This paper presents a stand-alone and menu-driven software package, Bayesian Regression: Nonparametric and Parametric Models, constructed from MATLAB Compiler. Currently, this package gives the user a choice from 83 Bayesian models for data analysis. They include 47 Bayesian nonparametric (BNP) infinite-mixture regression models; 5 BNP infinite-mixture models for density estimation; and 31 normal random effects models (HLMs), including normal linear models. Each of the 78 regression models handles either a continuous, binary, or ordinal dependent variable, and can handle multi-level (grouped) data. All 83 Bayesian models can handle the analysis of weighted observations (e.g., for meta-analysis), and the analysis of left-censored, right-censored, and/or interval-censored data. Each BNP infinite-mixture model has a mixture distribution assigned one of various BNP prior distributions, including priors defined by either the Dirichlet process, Pitman-Yor process (including the normalized stable process), beta (two-parameter) process, normalized inverse-Gaussian process, geometric weights prior, dependent Dirichlet process, or the dependent infinite-probits prior. The software user can mouse-click to select a Bayesian model and perform data analysis via Markov chain Monte Carlo (MCMC) sampling. After the sampling completes, the software automatically opens text output that reports MCMC-based estimates of the model's posterior distribution and model predictive fit to the data. Additional text and/or graphical output can be generated by mouse-clicking other menu options. This includes output of MCMC convergence analyses, and estimates of the model's posterior predictive distribution, for selected

  20. A software package for predicting design-flood hydrographs in small and ungauged basins

    OpenAIRE

    Rodolfo Piscopia; Andrea Petroselli; Salvatore Grimaldi

    2015-01-01

    In this study, software for estimating design hydrographs in small and ungauged basins is presented. The main aim is to propose a fast and user-friendly empirical tool that the practitioner can apply for hydrological studies characterised by a lack of observed data. The software implements a homonymous framework called event-based approach for small and ungauged basins (EBA4SUB) that was recently developed and tested by the authors to estimate the design peak discharge using the same input in...

  1. [Development of analysis software package for the two kinds of Japanese fluoro-d-glucose-positron emission tomography guideline].

    Science.gov (United States)

    Matsumoto, Keiichi; Endo, Keigo

    2013-06-01

    Two kinds of Japanese guidelines for the data acquisition protocol of oncology fluoro-D-glucose-positron emission tomography (FDG-PET)/computed tomography (CT) scans were created by the joint task force of the Japanese Society of Nuclear Medicine Technology (JSNMT) and the Japanese Society of Nuclear Medicine (JSNM), and published in Kakuigaku-Gijutsu 27(5): 425-456, 2007 and 29(2): 195-235, 2009. These guidelines aim to standardize PET image quality among facilities and different PET/CT scanner models. The objective of this study was to develop a personal computer-based performance measurement and image quality processor for the two kinds of Japanese guidelines for oncology (18)F-FDG PET/CT scans. We call this software package the "PET quality control tool" (PETquact). Microsoft Corporation's Windows(™) is used as the operating system for PETquact, which requires 1070×720 image resolution and includes 12 different applications. The accuracy was examined for numerous applications of PETquact. For example, in the sensitivity application, the system sensitivity measurement results were equivalent when comparing two PET sinograms obtained from the PETquact and the report. PETquact is suited for analysis of the two kinds of Japanese guideline, and it shows excellent spec to performance measurements and image quality analysis. PETquact can be used at any facility if the software package is installed on a laptop computer.

  2. PmagPy: Software Package for Paleomagnetic Data Analysis and Gateway to the Magnetics Information Consortium (MagIC) Database

    Science.gov (United States)

    Jonestrask, L.; Tauxe, L.; Shaar, R.; Jarboe, N.; Minnett, R.; Koppers, A. A. P.

    2014-12-01

    There are many data types and methods of analysis in rock and paleomagnetic investigations. The MagIC database (http://earthref.org/MAGIC) was designed to accommodate the vast majority of data used in such investigations. Yet getting data from the laboratory into the database, and visualizing and re-analyzing data downloaded from the database, makes special demands on data formatting. There are several recently published programming packages that deal with single types of data: demagnetization experiments (e.g., Lurcock et al., 2012), paleointensity experiments (e.g., Leonhardt et al., 2004), and FORC diagrams (e.g., Harrison et al., 2008). However, there is a need for a unified set of open source, cross-platform software that deals with the great variety of data types in a consistent way and facilitates importing data into the MagIC format, analyzing them and uploading them into the MagIC database. The PmagPy software package (http://earthref.org/PmagPy/cookbook/) comprises a such a comprehensive set of tools. It facilitates conversion of many laboratory formats into the common MagIC format and allows interpretation of demagnetization and Thellier-type experimental data. With some 175 programs and over 250 functions, it can be used to create a wide variety of plots and allows manipulation of downloaded data sets as well as preparation of new contributions for uploading to the MagIC database.

  3. A Re-Engineered Software Interface and Workflow for the Open-Source SimVascular Cardiovascular Modeling Package.

    Science.gov (United States)

    Lan, Hongzhi; Updegrove, Adam; Wilson, Nathan M; Maher, Gabriel D; Shadden, Shawn C; Marsden, Alison L

    2018-02-01

    Patient-specific simulation plays an important role in cardiovascular disease research, diagnosis, surgical planning and medical device design, as well as education in cardiovascular biomechanics. simvascular is an open-source software package encompassing an entire cardiovascular modeling and simulation pipeline from image segmentation, three-dimensional (3D) solid modeling, and mesh generation, to patient-specific simulation and analysis. SimVascular is widely used for cardiovascular basic science and clinical research as well as education, following increased adoption by users and development of a GATEWAY web portal to facilitate educational access. Initial efforts of the project focused on replacing commercial packages with open-source alternatives and adding increased functionality for multiscale modeling, fluid-structure interaction (FSI), and solid modeling operations. In this paper, we introduce a major SimVascular (SV) release that includes a new graphical user interface (GUI) designed to improve user experience. Additional improvements include enhanced data/project management, interactive tools to facilitate user interaction, new boundary condition (BC) functionality, plug-in mechanism to increase modularity, a new 3D segmentation tool, and new computer-aided design (CAD)-based solid modeling capabilities. Here, we focus on major changes to the software platform and outline features added in this new release. We also briefly describe our recent experiences using SimVascular in the classroom for bioengineering education.

  4. Particle Data Management Software for 3DParticle Tracking Velocimetry and Related Applications – The Flowtracks Package

    Directory of Open Access Journals (Sweden)

    Yosef Meller

    2016-06-01

    Full Text Available The Particle Tracking Velocimetry (PTV community employs several formats of particle information such as position and velocity as function of time, i.e. trajectory data, as a result of diverging needs unmet by existing formats, and a number of different, mostly home-grown, codes for handling the data. Flowtracks is a Python package that provides a single code base for accessing different formats as a database, i.e. storing data and programmatically manipulating them using format-agnostic data structures. Furthermore, it offers an HDF5-based format that is fast and extensible, obviating the need for other formats. The package may be obtained from https://github.com/OpenPTV/postptv and used as-is by many fluid-dynamics labs, or with minor extensions adhering to a common interface, by researchers from other fields, such as biology and population tracking.

  5. An analysis of distribution transformer failure using the statistical package for the social sciences (SPSS software

    Directory of Open Access Journals (Sweden)

    María Gabriela Mago Ramos

    2012-05-01

    Full Text Available A methodology was developed for analysing faults in distribution transformers using the statistical package for social sciences (SPSS; it consisted of organising and creating of database regarding failed equipment, incorporating such data into the processing programme and converting all the information into numerical variables to be processed, thereby obtaining descriptive statistics and enabling factor and discriminant analysis. The research was based on information provided by companies in areas served by Corpoelec (Valencia, Venezuela and Codensa (Bogotá, Colombia.

  6. GERMINATOR: a software package for high-throughput scoring and curve fitting of Arabidopsis seed germination.

    Science.gov (United States)

    Joosen, Ronny V L; Kodde, Jan; Willems, Leo A J; Ligterink, Wilco; van der Plas, Linus H W; Hilhorst, Henk W M

    2010-04-01

    Over the past few decades seed physiology research has contributed to many important scientific discoveries and has provided valuable tools for the production of high quality seeds. An important instrument for this type of research is the accurate quantification of germination; however gathering cumulative germination data is a very laborious task that is often prohibitive to the execution of large experiments. In this paper we present the germinator package: a simple, highly cost-efficient and flexible procedure for high-throughput automatic scoring and evaluation of germination that can be implemented without the use of complex robotics. The germinator package contains three modules: (i) design of experimental setup with various options to replicate and randomize samples; (ii) automatic scoring of germination based on the color contrast between the protruding radicle and seed coat on a single image; and (iii) curve fitting of cumulative germination data and the extraction, recap and visualization of the various germination parameters. The curve-fitting module enables analysis of general cumulative germination data and can be used for all plant species. We show that the automatic scoring system works for Arabidopsis thaliana and Brassica spp. seeds, but is likely to be applicable to other species, as well. In this paper we show the accuracy, reproducibility and flexibility of the germinator package. We have successfully applied it to evaluate natural variation for salt tolerance in a large population of recombinant inbred lines and were able to identify several quantitative trait loci for salt tolerance. Germinator is a low-cost package that allows the monitoring of several thousands of germination tests, several times a day by a single person.

  7. PONDEROSA-C/S: client-server based software package for automated protein 3D structure determination.

    Science.gov (United States)

    Lee, Woonghee; Stark, Jaime L; Markley, John L

    2014-11-01

    Peak-picking Of Noe Data Enabled by Restriction Of Shift Assignments-Client Server (PONDEROSA-C/S) builds on the original PONDEROSA software (Lee et al. in Bioinformatics 27:1727-1728. doi: 10.1093/bioinformatics/btr200, 2011) and includes improved features for structure calculation and refinement. PONDEROSA-C/S consists of three programs: Ponderosa Server, Ponderosa Client, and Ponderosa Analyzer. PONDEROSA-C/S takes as input the protein sequence, a list of assigned chemical shifts, and nuclear Overhauser data sets ((13)C- and/or (15)N-NOESY). The output is a set of assigned NOEs and 3D structural models for the protein. Ponderosa Analyzer supports the visualization, validation, and refinement of the results from Ponderosa Server. These tools enable semi-automated NMR-based structure determination of proteins in a rapid and robust fashion. We present examples showing the use of PONDEROSA-C/S in solving structures of four proteins: two that enable comparison with the original PONDEROSA package, and two from the Critical Assessment of automated Structure Determination by NMR (Rosato et al. in Nat Methods 6:625-626. doi: 10.1038/nmeth0909-625 , 2009) competition. The software package can be downloaded freely in binary format from http://pine.nmrfam.wisc.edu/download_packages.html. Registered users of the National Magnetic Resonance Facility at Madison can submit jobs to the PONDEROSA-C/S server at http://ponderosa.nmrfam.wisc.edu, where instructions, tutorials, and instructions can be found. Structures are normally returned within 1-2 days.

  8. HYPERDIRE HYPERgeometric functions DIfferential REduction. Mathematica-based packages for the differential reduction of generalized hypergeometric functions. Lauricella function FC of three variables

    International Nuclear Information System (INIS)

    Bytev, Vladimir V.; Kniehl, Bernd A.

    2016-12-01

    We present a further extension of the HYPERDIRE project, which is devoted to the creation of a set of Mathematica-based program packages for manipulations with Horn-type hypergeometric functions on the basis of differential equations. Specifically, we present the implementation of the differential reduction for the Lauricella function F C of three variables.

  9. HYPERDIRE HYPERgeometric functions DIfferential REduction. Mathematica-based packages for the differential reduction of generalized hypergeometric functions. Lauricella function F{sub C} of three variables

    Energy Technology Data Exchange (ETDEWEB)

    Bytev, Vladimir V. [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Joint Institute for Nuclear Research, Dubna (Russian Federation); Kniehl, Bernd A. [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik

    2016-12-15

    We present a further extension of the HYPERDIRE project, which is devoted to the creation of a set of Mathematica-based program packages for manipulations with Horn-type hypergeometric functions on the basis of differential equations. Specifically, we present the implementation of the differential reduction for the Lauricella function F{sub C} of three variables.

  10. Area of ischemia assessed by physicians and software packages from myocardial perfusion scintigrams

    DEFF Research Database (Denmark)

    Edenbrandt, L.; Hoglund, P.; Frantz, S.

    2014-01-01

    medicine delineated the extent of the ischemic defects. After at least two weeks, they delineated the defects again, and were this time provided a suggestion of the defect delineation by EXINI Heart(TM) (EXINI). Summed difference scores and ischemic extent values were obtained from four software programs......Background: The European Society of Cardiology recommends that patients with > 10% area of ischemia should receive revascularization. We investigated inter-observer variability for the extent of ischemic defects reported by different physicians and by different software tools, and if inter....... Results: The median extent values obtained from the 11 physicians varied between 8% and 34%, and between 9% and 16% for the software programs. For all 25 patients, mean extent obtained from EXINI was 17.0% (+/- standard deviation (SD) 14.6%). Mean extent for physicians was 22.6% (+/- 15.6%) for the first...

  11. Intrinsic noise analyzer: a software package for the exploration of stochastic biochemical kinetics using the system size expansion.

    Science.gov (United States)

    Thomas, Philipp; Matuschek, Hannes; Grima, Ramon

    2012-01-01

    The accepted stochastic descriptions of biochemical dynamics under well-mixed conditions are given by the Chemical Master Equation and the Stochastic Simulation Algorithm, which are equivalent. The latter is a Monte-Carlo method, which, despite enjoying broad availability in a large number of existing software packages, is computationally expensive due to the huge amounts of ensemble averaging required for obtaining accurate statistical information. The former is a set of coupled differential-difference equations for the probability of the system being in any one of the possible mesoscopic states; these equations are typically computationally intractable because of the inherently large state space. Here we introduce the software package intrinsic Noise Analyzer (iNA), which allows for systematic analysis of stochastic biochemical kinetics by means of van Kampen's system size expansion of the Chemical Master Equation. iNA is platform independent and supports the popular SBML format natively. The present implementation is the first to adopt a complementary approach that combines state-of-the-art analysis tools using the computer algebra system Ginac with traditional methods of stochastic simulation. iNA integrates two approximation methods based on the system size expansion, the Linear Noise Approximation and effective mesoscopic rate equations, which to-date have not been available to non-expert users, into an easy-to-use graphical user interface. In particular, the present methods allow for quick approximate analysis of time-dependent mean concentrations, variances, covariances and correlations coefficients, which typically outperforms stochastic simulations. These analytical tools are complemented by automated multi-core stochastic simulations with direct statistical evaluation and visualization. We showcase iNA's performance by using it to explore the stochastic properties of cooperative and non-cooperative enzyme kinetics and a gene network associated with

  12. A software package for predicting design-flood hydrographs in small and ungauged basins

    Directory of Open Access Journals (Sweden)

    Rodolfo Piscopia

    2015-06-01

    Full Text Available In this study, software for estimating design hydrographs in small and ungauged basins is presented. The main aim is to propose a fast and user-friendly empirical tool that the practitioner can apply for hydrological studies characterised by a lack of observed data. The software implements a homonymous framework called event-based approach for small and ungauged basins (EBA4SUB that was recently developed and tested by the authors to estimate the design peak discharge using the same input information necessary to apply the rational formula. EBA4SUB is a classical hydrological event-based model in which each step (design hyetograph, net rainfall estimation, and rainfall-runoff transformation is appropriately adapted for empirical applications without calibration. As a case study, the software is applied in a small watershed while varying the hyetograph shape, rainfall peak position, and return time. The results provide an overview of the software and confirm the secondary role of the design rainfall peak position.

  13. Lung nodule volumetry: segmentation algorithms within the same software package cannot be used interchangeably.

    NARCIS (Netherlands)

    Ashraf, H.; Hoop, B.J. de; Shaker, S.B.; Dirksen, A.; Bach, K.S.; Hansen, H.; Prokop, M.; Pedersen, J.H.

    2010-01-01

    OBJECTIVE: We examined the reproducibility of lung nodule volumetry software that offers three different volumetry algorithms. METHODS: In a lung cancer screening trial, 188 baseline nodules >5 mm were identified. Including follow-ups, these nodules formed a study-set of 545 nodules. Nodules were

  14. A software package for patient-specific dosimetry in the locoregional RIT of gliomas using 188Re labelled NIMOTUZUMAB

    International Nuclear Information System (INIS)

    Torres, L.A.; Coca, M.A.; Sanchez, Y.; Cornejo, N.; Catasus, C.; Denaro, M. de

    2008-01-01

    Full text: The locoregional treatment of high-grade gliomas using beta emitter compounds allows delivering high radiation doses in the tumor bed and the brain adjacent tissues of patients suffering these aggressive malignancies. The main goal of this work was to implement patient-specific dosimetry procedures using a voxel-based methodology in order to compute and analyze the three-dimensional doses distributions received by the patients undergoing loco-regional treatment of gliomas with the 188 Re labeled MAb NIMOTUZUMAB. A software package called TRIDOSE has been developed to perform the image managing, volume registration, dose calculations and qualitative and quantitative analysis of the results, including dose-volume histograms and isodose curves. The dosimetric factors at voxel level for 188 Re ('S' values) were estimated using two different methods, Monte Carlo simulations of energy transport and deposition and the integration of the dose kernel functions. A quality control module was also implemented in order to test the software using well-known 3D distribution of activities or counts. The TRIDOSE outputs were compared with other commercial software showing relative differences lower than 1.10% for different sphere sizes. The established dosimetric procedures constitute a useful tool to compute the absorbed doses received by patients undergoing radioimmunotherapy of brain tumors with 188 Re-NIMOTUZUMAB. (author)

  15. TENSOLVE: A software package for solving systems of nonlinear equations and nonlinear least squares problems using tensor methods

    Energy Technology Data Exchange (ETDEWEB)

    Bouaricha, A. [Argonne National Lab., IL (United States). Mathematics and Computer Science Div.; Schnabel, R.B. [Colorado Univ., Boulder, CO (United States). Dept. of Computer Science

    1996-12-31

    This paper describes a modular software package for solving systems of nonlinear equations and nonlinear least squares problems, using a new class of methods called tensor methods. It is intended for small to medium-sized problems, say with up to 100 equations and unknowns, in cases where it is reasonable to calculate the Jacobian matrix or approximate it by finite differences at each iteration. The software allows the user to select between a tensor method and a standard method based upon a linear model. The tensor method models F({ital x}) by a quadratic model, where the second-order term is chosen so that the model is hardly more expensive to form, store, or solve than the standard linear model. Moreover, the software provides two different global strategies, a line search and a two- dimensional trust region approach. Test results indicate that, in general, tensor methods are significantly more efficient and robust than standard methods on small and medium-sized problems in iterations and function evaluations.

  16. Decon2LS: An open-source software package for automated processing and visualization of high resolution mass spectrometry data.

    Science.gov (United States)

    Jaitly, Navdeep; Mayampurath, Anoop; Littlefield, Kyle; Adkins, Joshua N; Anderson, Gordon A; Smith, Richard D

    2009-03-17

    Data generated from liquid chromatography coupled to high-resolution mass spectrometry (LC-MS)-based studies of a biological sample can contain large amounts of biologically significant information in the form of proteins, peptides, and metabolites. Interpreting this data involves inferring the masses and abundances of biomolecules injected into the instrument. Because of the inherent complexity of mass spectral patterns produced by these biomolecules, the analysis is significantly enhanced by using visualization capabilities to inspect and confirm results. In this paper we describe Decon2LS, an open-source software package for automated processing and visualization of high-resolution MS data. Drawing extensively on algorithms developed over the last ten years for ICR2LS, Decon2LS packages the algorithms as a rich set of modular, reusable processing classes for performing diverse functions such as reading raw data, routine peak finding, theoretical isotope distribution modelling, and deisotoping. Because the source code is openly available, these functionalities can now be used to build derivative applications in relatively fast manner. In addition, Decon2LS provides an extensive set of visualization tools, such as high performance chart controls. With a variety of options that include peak processing, deisotoping, isotope composition, etc, Decon2LS supports processing of multiple raw data formats. Deisotoping can be performed on an individual scan, an individual dataset, or on multiple datasets using batch processing. Other processing options include creating a two dimensional view of mass and liquid chromatography (LC) elution time features, generating spectrum files for tandem MS data, creating total intensity chromatograms, and visualizing theoretical peptide profiles. Application of Decon2LS to deisotope different datasets obtained across different instruments yielded a high number of features that can be used to identify and quantify peptides in the

  17. Decon2LS: An open-source software package for automated processing and visualization of high resolution mass spectrometry data

    Directory of Open Access Journals (Sweden)

    Anderson Gordon A

    2009-03-01

    Full Text Available Abstract Background Data generated from liquid chromatography coupled to high-resolution mass spectrometry (LC-MS-based studies of a biological sample can contain large amounts of biologically significant information in the form of proteins, peptides, and metabolites. Interpreting this data involves inferring the masses and abundances of biomolecules injected into the instrument. Because of the inherent complexity of mass spectral patterns produced by these biomolecules, the analysis is significantly enhanced by using visualization capabilities to inspect and confirm results. In this paper we describe Decon2LS, an open-source software package for automated processing and visualization of high-resolution MS data. Drawing extensively on algorithms developed over the last ten years for ICR2LS, Decon2LS packages the algorithms as a rich set of modular, reusable processing classes for performing diverse functions such as reading raw data, routine peak finding, theoretical isotope distribution modelling, and deisotoping. Because the source code is openly available, these functionalities can now be used to build derivative applications in relatively fast manner. In addition, Decon2LS provides an extensive set of visualization tools, such as high performance chart controls. Results With a variety of options that include peak processing, deisotoping, isotope composition, etc, Decon2LS supports processing of multiple raw data formats. Deisotoping can be performed on an individual scan, an individual dataset, or on multiple datasets using batch processing. Other processing options include creating a two dimensional view of mass and liquid chromatography (LC elution time features, generating spectrum files for tandem MS data, creating total intensity chromatograms, and visualizing theoretical peptide profiles. Application of Decon2LS to deisotope different datasets obtained across different instruments yielded a high number of features that can be used to

  18. DRUGDOG 3:0: U.S. Navy Random Urinalysis software package

    OpenAIRE

    Wilson, Dale E.

    1994-01-01

    Approved for public release; distribution is unlimited Although the United States Navy has had a mandatory Random Urinalysis Program in effect for many years, there has never been a formal, standardize methodology to implement the process. OPNAV INSTRUCTION 5350.4 (series) provides guidance on what must be accomplished, but not how to accomplish it. Automation and standardization of the program through software implementation can lend confidence to personnel who undergo urinalysis testing ...

  19. Is liver perfusion CT reproducible? A study on intra- and interobserver agreement of normal hepatic haemodynamic parameters obtained with two different software packages.

    Science.gov (United States)

    Bretas, Elisa Almeida Sathler; Torres, Ulysses S; Torres, Lucas Rios; Bekhor, Daniel; Saito Filho, Celso Fernando; Racy, Douglas Jorge; Faggioni, Lorenzo; D'Ippolito, Giuseppe

    2017-10-01

    To evaluate the agreement between the measurements of perfusion CT parameters in normal livers by using two different software packages. This retrospective study was based on 78 liver perfusion CT examinations acquired for detecting suspected liver metastasis. Patients with any morphological or functional hepatic abnormalities were excluded. The final analysis included 37 patients (59.7 ± 14.9 y). Two readers (1 and 2) independently measured perfusion parameters using different software packages from two major manufacturers (A and B). Arterial perfusion (AP) and portal perfusion (PP) were determined using the dual-input vascular one-compartmental model. Inter-reader agreement for each package and intrareader agreement between both packages were assessed with intraclass correlation coefficients (ICC) and Bland-Altman statistics. Inter-reader agreement was substantial for AP using software A (ICC = 0.82) and B (ICC = 0.85-0.86), fair for PP using software A (ICC = 0.44) and fair to moderate for PP using software B (ICC = 0.56-0.77). Intrareader agreement between software A and B ranged from slight to moderate (ICC = 0.32-0.62) for readers 1 and 2 considering the AP parameters, and from fair to moderate (ICC = 0.40-0.69) for readers 1 and 2 considering the PP parameters. At best there was only moderate agreement between both software packages, resulting in some uncertainty and suboptimal reproducibility. Advances in knowledge: Software-dependent factors may contribute to variance in perfusion measurements, demanding further technical improvements. AP measurements seem to be the most reproducible parameter to be adopted when evaluating liver perfusion CT.

  20. The IPNS rietveld analysis software package for TOF [time-of-flight] powder diffraction data: Recent developments

    International Nuclear Information System (INIS)

    Rotella, F.J.; Richardson, J.W. Jr.

    1987-01-01

    A system of FORTRAN programs for the analysis of time-of-flight (TOF) neutron powder diffraction data via the Rietveld method at IPNS has been modified recently, making it possible to analyze data that exhibit diffraction maxima broadened due to anisotropic strain and that can be modeled by individual atomic anharmonic thermal vibrations. The observation of noncrystalline scattering in data from some powder samples has led to the development of software to fit such scattering by a function related to a radial distribution function through Fourier-filtering techniques. The ''user friendliness'' of the IPNS Rietveld package has been enhanced by the development of ''RIETVELD,'' a menu-based VAX/VMS command language routine for interactive file manipulation and program execution

  1. Design and Implement a MapReduce Framework for Executing Standalone Software Packages in Hadoop-based Distributed Environments

    Directory of Open Access Journals (Sweden)

    Chao-Chun Chen

    2013-12-01

    Full Text Available The Hadoop MapReduce is the programming model of designing the auto scalable distributed computing applications. It provides developer an effective environment to attain automatic parallelization. However, most existing manufacturing systems are arduous and restrictive to migrate to MapReduce private cloud, due to the platform incompatible and tremendous complexity of system reconstruction. For increasing the efficiency of manufacturing systems with minimum modification of existing systems, we design a framework in this thesis, called MC-Framework: Multi-uses-based Cloudizing-Application Framework. It provides the simple interface to users for fairly executing requested tasks worked with traditional standalone software packages in MapReduce-based private cloud environments. Moreover, this thesis focuses on the multiuser workloads, but the default Hadoop scheduling scheme, i.e., FIFO, would increase delay under multiuser scenarios. Hence, we also propose a new scheduling mechanism, called Job-Sharing Scheduling, to explore and fairly share the jobs to machines in the MapReduce-based private cloud. Then, we prototype an experimental virtual-metrology module of a manufacturing system as a case study to verify and analysis the proposed MC-Framework. The results of our experiments indicate that our proposed framework enormously improved the time performance compared with the original package.

  2. “DETECTION ARTIFACTS” SOFTWARE PACKAGE: FUNCTIONAL CAPABILITIES AND PROSPECTS OF USING (ON THE EXAMPLE OF GEOARCHEOLOGICAL RESEARCH

    Directory of Open Access Journals (Sweden)

    Ye. P. Krupochkin

    2017-01-01

    Full Text Available Mathematical and scientific methods are highly significant in modern geoarcheological study. They contribute to the development of new computer technologies and their implementing in geoarcheological research in particular, decoding and photogrammetric processing of space images.The article focuses on the “Detection Artifacts”software package designed for thematic aerospace image decoding which is aimed at making the search automatic for various archeological sites, both natural and artificially created ones. The main attention is drawn to decoding of archeological sites using methods of morphological analysis and indicative decoding.Its work is based on two groups of methods of image computer processing: 1 an image enhancement method which is carried out with the help of spatial frequency filtration, and 2 a method of morphometric analysis. The methods of spatial frequency filtration can be used to solve two problems: information noise minimization and edge enhancement. To achieve the best results using the methods of spatial frequency filtration it is necessary to have all the information of relevance to the objects of searching.Searching for various archeological sites is not only photogrammetric task. In fact, this problem can be solved in the sphere of photogrammetry with the application of aerospace and computer methods. The authors stress the idea in order to avoid terminology ambiguity and confusion when describing the essence of the methods and processes. It should be noted that the work with the images must be executed in a strict sequence. First and foremost, photogrammetric processing – atmospheric correction, geometric adjustment, conversion and geo targeting should be implemented. And only after that one can proceed to decoding the information.When creating the software package a modular structure was applied that favorably affected the tasks being solved and corresponded to the conception of search for archaeological objects

  3. MedXViewer: an extensible web-enabled software package for medical imaging

    Science.gov (United States)

    Looney, P. T.; Young, K. C.; Mackenzie, Alistair; Halling-Brown, Mark D.

    2014-03-01

    MedXViewer (Medical eXtensible Viewer) is an application designed to allow workstation-independent, PACS-less viewing and interaction with anonymised medical images (e.g. observer studies). The application was initially implemented for use in digital mammography and tomosynthesis but the flexible software design allows it to be easily extended to other imaging modalities. Regions of interest can be identified by a user and any associated information about a mark, an image or a study can be added. The questions and settings can be easily configured depending on the need of the research allowing both ROC and FROC studies to be performed. The extensible nature of the design allows for other functionality and hanging protocols to be available for each study. Panning, windowing, zooming and moving through slices are all available while modality-specific features can be easily enabled e.g. quadrant zooming in mammographic studies. MedXViewer can integrate with a web-based image database allowing results and images to be stored centrally. The software and images can be downloaded remotely from this centralised data-store. Alternatively, the software can run without a network connection where the images and results can be encrypted and stored locally on a machine or external drive. Due to the advanced workstation-style functionality, the simple deployment on heterogeneous systems over the internet without a requirement for administrative access and the ability to utilise a centralised database, MedXViewer has been used for running remote paper-less observer studies and is capable of providing a training infrastructure and co-ordinating remote collaborative viewing sessions (e.g. cancer reviews, interesting cases).

  4. PDBStat: a universal restraint converter and restraint analysis software package for protein NMR

    International Nuclear Information System (INIS)

    Tejero, Roberto; Snyder, David; Mao, Binchen; Aramini, James M.; Montelione, Gaetano T.

    2013-01-01

    The heterogeneous array of software tools used in the process of protein NMR structure determination presents organizational challenges in the structure determination and validation processes, and creates a learning curve that limits the broader use of protein NMR in biology. These challenges, including accurate use of data in different data formats required by software carrying out similar tasks, continue to confound the efforts of novices and experts alike. These important issues need to be addressed robustly in order to standardize protein NMR structure determination and validation. PDBStat is a C/C++ computer program originally developed as a universal coordinate and protein NMR restraint converter. Its primary function is to provide a user-friendly tool for interconverting between protein coordinate and protein NMR restraint data formats. It also provides an integrated set of computational methods for protein NMR restraint analysis and structure quality assessment, relabeling of prochiral atoms with correct IUPAC names, as well as multiple methods for analysis of the consistency of atomic positions indicated by their convergence across a protein NMR ensemble. In this paper we provide a detailed description of the PDBStat software, and highlight some of its valuable computational capabilities. As an example, we demonstrate the use of the PDBStat restraint converter for restrained CS-Rosetta structure generation calculations, and compare the resulting protein NMR structure models with those generated from the same NMR restraint data using more traditional structure determination methods. These results demonstrate the value of a universal restraint converter in allowing the use of multiple structure generation methods with the same restraint data for consensus analysis of protein NMR structures and the underlying restraint data

  5. PDBStat: a universal restraint converter and restraint analysis software package for protein NMR

    Energy Technology Data Exchange (ETDEWEB)

    Tejero, Roberto [Rutgers, The State University of New Jersey, Center for Advanced Biotechnology and Medicine (United States); Snyder, David [William Paterson University, Department of Chemistry (United States); Mao, Binchen; Aramini, James M.; Montelione, Gaetano T., E-mail: guy@cabm.rutgers.edu [Rutgers, The State University of New Jersey, Center for Advanced Biotechnology and Medicine (United States)

    2013-08-15

    The heterogeneous array of software tools used in the process of protein NMR structure determination presents organizational challenges in the structure determination and validation processes, and creates a learning curve that limits the broader use of protein NMR in biology. These challenges, including accurate use of data in different data formats required by software carrying out similar tasks, continue to confound the efforts of novices and experts alike. These important issues need to be addressed robustly in order to standardize protein NMR structure determination and validation. PDBStat is a C/C++ computer program originally developed as a universal coordinate and protein NMR restraint converter. Its primary function is to provide a user-friendly tool for interconverting between protein coordinate and protein NMR restraint data formats. It also provides an integrated set of computational methods for protein NMR restraint analysis and structure quality assessment, relabeling of prochiral atoms with correct IUPAC names, as well as multiple methods for analysis of the consistency of atomic positions indicated by their convergence across a protein NMR ensemble. In this paper we provide a detailed description of the PDBStat software, and highlight some of its valuable computational capabilities. As an example, we demonstrate the use of the PDBStat restraint converter for restrained CS-Rosetta structure generation calculations, and compare the resulting protein NMR structure models with those generated from the same NMR restraint data using more traditional structure determination methods. These results demonstrate the value of a universal restraint converter in allowing the use of multiple structure generation methods with the same restraint data for consensus analysis of protein NMR structures and the underlying restraint data.

  6. Informed-Proteomics: open-source software package for top-down proteomics

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jungkap; Piehowski, Paul D.; Wilkins, Christopher; Zhou, Mowei; Mendoza, Joshua; Fujimoto, Grant M.; Gibbons, Bryson C.; Shaw, Jared B.; Shen, Yufeng; Shukla, Anil K.; Moore, Ronald J.; Liu, Tao; Petyuk, Vladislav A.; Tolić, Nikola; Paša-Tolić, Ljiljana; Smith, Richard D.; Payne, Samuel H.; Kim, Sangtae

    2017-08-07

    Top-down proteomics involves the analysis of intact proteins. This approach is very attractive as it allows for analyzing proteins in their endogenous form without proteolysis, preserving valuable information about post-translation modifications, isoforms, proteolytic processing or their combinations collectively called proteoforms. Moreover, the quality of the top-down LC-MS/MS datasets is rapidly increasing due to advances in the liquid chromatography and mass spectrometry instrumentation and sample processing protocols. However, the top-down mass spectra are substantially more complex compare to the more conventional bottom-up data. To take full advantage of the increasing quality of the top-down LC-MS/MS datasets there is an urgent need to develop algorithms and software tools for confident proteoform identification and quantification. In this study we present a new open source software suite for top-down proteomics analysis consisting of an LC-MS feature finding algorithm, a database search algorithm, and an interactive results viewer. The presented tool along with several other popular tools were evaluated using human-in-mouse xenograft luminal and basal breast tumor samples that are known to have significant differences in protein abundance based on bottom-up analysis.

  7. SpcAudace: Spectroscopic processing and analysis package of Audela software

    Science.gov (United States)

    Mauclaire, Benjamin

    2017-11-01

    SpcAudace processes long slit spectra with automated pipelines and performs astrophysical analysis of the latter data. These powerful pipelines do all the required steps in one pass: standard preprocessing, masking of bad pixels, geometric corrections, registration, optimized spectrum extraction, wavelength calibration and instrumental response computation and correction. Both high and low resolution long slit spectra are managed for stellar and non-stellar targets. Many types of publication-quality figures can be easily produced: pdf and png plots or annotated time series plots. Astrophysical quantities can be derived from individual or large amount of spectra with advanced functions: from line profile characteristics to equivalent width and periodogram. More than 300 documented functions are available and can be used into TCL scripts for automation. SpcAudace is based on Audela open source software.

  8. Intrinsic noise analyzer: a software package for the exploration of stochastic biochemical kinetics using the system size expansion.

    Directory of Open Access Journals (Sweden)

    Philipp Thomas

    Full Text Available The accepted stochastic descriptions of biochemical dynamics under well-mixed conditions are given by the Chemical Master Equation and the Stochastic Simulation Algorithm, which are equivalent. The latter is a Monte-Carlo method, which, despite enjoying broad availability in a large number of existing software packages, is computationally expensive due to the huge amounts of ensemble averaging required for obtaining accurate statistical information. The former is a set of coupled differential-difference equations for the probability of the system being in any one of the possible mesoscopic states; these equations are typically computationally intractable because of the inherently large state space. Here we introduce the software package intrinsic Noise Analyzer (iNA, which allows for systematic analysis of stochastic biochemical kinetics by means of van Kampen's system size expansion of the Chemical Master Equation. iNA is platform independent and supports the popular SBML format natively. The present implementation is the first to adopt a complementary approach that combines state-of-the-art analysis tools using the computer algebra system Ginac with traditional methods of stochastic simulation. iNA integrates two approximation methods based on the system size expansion, the Linear Noise Approximation and effective mesoscopic rate equations, which to-date have not been available to non-expert users, into an easy-to-use graphical user interface. In particular, the present methods allow for quick approximate analysis of time-dependent mean concentrations, variances, covariances and correlations coefficients, which typically outperforms stochastic simulations. These analytical tools are complemented by automated multi-core stochastic simulations with direct statistical evaluation and visualization. We showcase iNA's performance by using it to explore the stochastic properties of cooperative and non-cooperative enzyme kinetics and a gene network

  9. Intrinsic Noise Analyzer: A Software Package for the Exploration of Stochastic Biochemical Kinetics Using the System Size Expansion

    Science.gov (United States)

    Grima, Ramon

    2012-01-01

    The accepted stochastic descriptions of biochemical dynamics under well-mixed conditions are given by the Chemical Master Equation and the Stochastic Simulation Algorithm, which are equivalent. The latter is a Monte-Carlo method, which, despite enjoying broad availability in a large number of existing software packages, is computationally expensive due to the huge amounts of ensemble averaging required for obtaining accurate statistical information. The former is a set of coupled differential-difference equations for the probability of the system being in any one of the possible mesoscopic states; these equations are typically computationally intractable because of the inherently large state space. Here we introduce the software package intrinsic Noise Analyzer (iNA), which allows for systematic analysis of stochastic biochemical kinetics by means of van Kampen’s system size expansion of the Chemical Master Equation. iNA is platform independent and supports the popular SBML format natively. The present implementation is the first to adopt a complementary approach that combines state-of-the-art analysis tools using the computer algebra system Ginac with traditional methods of stochastic simulation. iNA integrates two approximation methods based on the system size expansion, the Linear Noise Approximation and effective mesoscopic rate equations, which to-date have not been available to non-expert users, into an easy-to-use graphical user interface. In particular, the present methods allow for quick approximate analysis of time-dependent mean concentrations, variances, covariances and correlations coefficients, which typically outperforms stochastic simulations. These analytical tools are complemented by automated multi-core stochastic simulations with direct statistical evaluation and visualization. We showcase iNA’s performance by using it to explore the stochastic properties of cooperative and non-cooperative enzyme kinetics and a gene network associated with

  10. Constraint Network Analysis (CNA): a Python software package for efficiently linking biomacromolecular structure, flexibility, (thermo-)stability, and function.

    Science.gov (United States)

    Pfleger, Christopher; Rathi, Prakash Chandra; Klein, Doris L; Radestock, Sebastian; Gohlke, Holger

    2013-04-22

    For deriving maximal advantage from information on biomacromolecular flexibility and rigidity, results from rigidity analyses must be linked to biologically relevant characteristics of a structure. Here, we describe the Python-based software package Constraint Network Analysis (CNA) developed for this task. CNA functions as a front- and backend to the graph-based rigidity analysis software FIRST. CNA goes beyond the mere identification of flexible and rigid regions in a biomacromolecule in that it (I) provides a refined modeling of thermal unfolding simulations that also considers the temperature-dependence of hydrophobic tethers, (II) allows performing rigidity analyses on ensembles of network topologies, either generated from structural ensembles or by using the concept of fuzzy noncovalent constraints, and (III) computes a set of global and local indices for quantifying biomacromolecular stability. This leads to more robust results from rigidity analyses and extends the application domain of rigidity analyses in that phase transition points ("melting points") and unfolding nuclei ("structural weak spots") are determined automatically. Furthermore, CNA robustly handles small-molecule ligands in general. Such advancements are important for applying rigidity analysis to data-driven protein engineering and for estimating the influence of ligand molecules on biomacromolecular stability. CNA maintains the efficiency of FIRST such that the analysis of a single protein structure takes a few seconds for systems of several hundred residues on a single core. These features make CNA an interesting tool for linking biomacromolecular structure, flexibility, (thermo-)stability, and function. CNA is available from http://cpclab.uni-duesseldorf.de/software for nonprofit organizations.

  11. Verification and validation of the SAPHIRE Version 4.0 PRA software package

    International Nuclear Information System (INIS)

    Bolander, T.W.; Calley, M.B.; Capps, E.L.

    1994-02-01

    A verification and validation (V ampersand V) process has been performed for the System Analysis Programs for Hands-on Integrated Reliability Evaluation (SAPHIRE). SAPHIRE is a set of four computer programs that the Nuclear Regulatory Commission (NRC) developed to perform probabilistic risk assessments (PRAs). These programs allow an analyst to create, quantify, and evaluate the risk associated with a facility or process being analyzed. The programs included in this set are Integrated Reliability and Risk Analysis System (IRRAS), System Analysis and Risk Assessment (SARA), Models and Results Database (MAR-D), and Fault Tree/Event Tree/Piping and Instrumentation Diagram (FEP) graphical editor. The V ampersand V steps included a V ampersand V plan to describe the process and criteria by which the V ampersand V would be performed; a software requirements documentation review to determine the correctness, completeness, and traceability of the requirements; a user survey to determine the usefulness of the user documentation, identification and testing of vital and non-vital features, and documentation of the test results

  12. CALIPSO: an interactive image analysis software package for desktop PACS workstations

    Science.gov (United States)

    Ratib, Osman M.; Huang, H. K.

    1990-07-01

    The purpose of this project is to develop a low cost workstation for quantitative analysis of multimodality images using a Macintosh II personal computer. In the current configuration the Macintosh operates as a stand alone workstation where images are imported either from a central PACS server through a standard Ethernet network or recorded through video digitizer board. The CALIPSO software developed contains a large variety ofbasic image display and manipulation tools. We focused our effort however on the design and implementation ofquantitative analysis methods that can be applied to images from different imaging modalities. Analysis modules currently implemented include geometric and densitometric volumes and ejection fraction calculation from radionuclide and cine-angiograms Fourier analysis ofcardiac wall motion vascular stenosis measurement color coded parametric display of regional flow distribution from dynamic coronary angiograms automatic analysis ofmyocardial distribution ofradiolabelled tracers from tomoscintigraphic images. Several of these analysis tools were selected because they use similar color coded andparametric display methods to communicate quantitative data extracted from the images. 1. Rationale and objectives of the project Developments of Picture Archiving and Communication Systems (PACS) in clinical environment allow physicians and radiologists to assess radiographic images directly through imaging workstations (''). This convenient access to the images is often limited by the number of workstations available due in part to their high cost. There is also an increasing need for quantitative analysis ofthe images. During thepast decade

  13. Suitability of semi-automated tumor response assessment of liver metastases using a dedicated software package

    International Nuclear Information System (INIS)

    Kalkmann, Janine; Ladd, S.C.; Greiff, A. de; Forsting, M.; Stattaus, J.

    2010-01-01

    Purpose: to evaluate the suitability of semi-automated compared to manual tumor response assessment (TRA) of liver metastases. Materials and methods: in total, 32 patients with colorectal cancer and liver metastases were followed by an average of 2.8 contrast-enhanced CT scans. Two observers (O1, O2) measured the longest diameter (LD) of 269 liver metastases manually and semi-automatically using software installed as thin-client on a PACS workstation (LMS-Liver, MEDIAN Technologies). LD and TRA (''progressive'', ''stable'', ''partial remission'') were performed according to RECIST (Response Evaluation Criteria in Solid Tumors) and analyzed for between-method, interobserver and intraobserver variability. The time needed for evaluation was compared for both methods. Results: all measurements correlated excellently (r ≥ 0.96). Intraobserver (semi-automated), interobserver (manual) and between-method differences (by O1) in LD of 1.4 ± 2.6 mm, 1.9 ± 1.9 mm and 2.1 ± 2.0 mm, respectively, were not significant. Interobserver (semi-automated) and between-method (by O2) differences in LD of 3.0 ± 3.0 mm and 2.6 ± 2.0 mm, respectively, reflected a significant variability (p < 0.01). The interobserver agreement in manual and semi-automated TRA was 91.4%. The intraobserver agreement in semi-automated TRA was 84.5%. Between both methods a TRA agreement of 86.2% was obtained. Semi-automated evaluation (2.7 min) took slightly more time than manual evaluation (2.3 min). Conclusion: semi-automated and manual evaluation of liver metastases yield comparable results in response assessments and require comparable effort. (orig.)

  14. Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software

    International Nuclear Information System (INIS)

    Lee, Young Han; Song, Ho-Taek; Kim, Sungjun; Suh, Jin-Suck; Park, Kwan Kyu

    2012-01-01

    To assess the usefulness of gemstone spectral imaging (GSI) dual-energy CT (DECT) with/without metal artefact reduction software (MARs). The DECTs were performed using fast kV-switching GSI between 80 and 140 kV. The CT data were retro-reconstructed with/without MARs, by different displayed fields-of-view (DFOV), and with synthesised monochromatic energy in the range 40-140 keV. A phantom study of size and CT numbers was performed in a titanium plate and a stainless steel plate. A clinical study was performed in 26 patients with metallic hardware. All images were retrospectively reviewed in terms of the visualisation of periprosthetic regions and the severity of beam-hardening artefacts by using a five-point scale. The GSI-MARs reconstruction can markedly reduce the metal-related artefacts, and the image quality was affected by the prosthesis composition and DFOV. The spectral CT numbers of the prosthesis and periprosthetic regions showed different patterns on stainless steel and titanium plates. Dual-energy CT with GSI-MARs can reduce metal-related artefacts and improve the delineation of the prosthesis and periprosthetic region. We should be cautious when using GSI-MARs because the image quality was affected by the prosthesis composition, energy (in keV) and DFOV. The metallic composition and size should be considered in metallic imaging with GSI-MARs reconstruction. circle Metal-related artefacts can be troublesome on musculoskeletal computed tomography (CT). circle Gemstone spectral imaging (GSI) with dual-energy CT (DECT) offers a novel solution circle GSI and metallic artefact reduction software (GSI-MAR) can markedly reduce these artefacts. circle However image quality is influenced by the prosthesis composition and other parameters. circle We should be aware about potential overcorrection when using GSI-MARs. (orig.)

  15. The user's manual of 'Manyo Library' data reduction software framework at MLF, J-PARC

    International Nuclear Information System (INIS)

    Inamura, Yasuhiro; Nakatani, Takeshi; Ito, Takayoshi; Suzuki, Jiro

    2016-06-01

    Manyo Library is a software framework for developing analysis software of neutron scattering data produced at MLF, J-PARC. This software framework is required to work on many instruments in MLF and to include base functions applied to various scientific purposes at beam lines. This framework mainly consists of data containers, which enable to store 1, 2 and 3 dimensional axes data for neutron scattering. Data containers have many functions to calculate four arithmetic operations with errors distribution between containers, to store the meta-data about measurements and to read or write text file. The analysis codes are constructed using various analysis operators defined in Manyo Library, which executes functions with given data containers and output the results. On the other hands, the main interface for instrument scientists and users must be easy and interactive to treat data containers and functions or to develop new analysis codes. Therefore we chose Python as user interface. Since Manyo Library is built in C++ language, we've introduced the technology to call C++ function from Python environment into the framework. As a result, we have already developed a lot of software for data reduction, analysis and visualization, which are utilized widely in beam lines at MLF. This document is the manual for the beginner to touch this framework. (author)

  16. Software

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, R.; Budd, G.; Ross, E.; Wells, P.

    2010-07-15

    The software section of this journal presented new software programs that have been developed to help in the exploration and development of hydrocarbon resources. Software provider IHS Inc. has made additions to its geological and engineering analysis software tool, IHS PETRA, a product used by geoscientists and engineers to visualize, analyze and manage well production, well log, drilling, reservoir, seismic and other related information. IHS PETRA also includes a directional well module and a decline curve analysis module to improve analysis capabilities in unconventional reservoirs. Petris Technology Inc. has developed a software to help manage the large volumes of data. PetrisWinds Enterprise (PWE) helps users find and manage wellbore data, including conventional wireline and MWD core data; analysis core photos and images; waveforms and NMR; and external files documentation. Ottawa-based Ambercore Software Inc. has been collaborating with Nexen on the Petroleum iQ software for steam assisted gravity drainage (SAGD) producers. Petroleum iQ integrates geology and geophysics data with engineering data in 3D and 4D. Calgary-based Envirosoft Corporation has developed a software that reduces the costly and time-consuming effort required to comply with Directive 39 of the Alberta Energy Resources Conservation Board. The product includes an emissions modelling software. Houston-based Seismic Micro-Technology (SMT) has developed the Kingdom software that features the latest in seismic interpretation. Holland-based Joa Oil and Gas and Calgary-based Computer Modelling Group have both supplied the petroleum industry with advanced reservoir simulation software that enables reservoir interpretation. The 2010 software survey included a guide to new software applications designed to facilitate petroleum exploration, drilling and production activities. Oil and gas producers can use the products for a range of functions, including reservoir characterization and accounting. In

  17. The STARLINK software collection

    Science.gov (United States)

    Penny, A. J.; Wallace, P. T.; Sherman, J. C.; Terret, D. L.

    1993-12-01

    A demonstration will be given of some recent Starlink software. STARLINK is: a network of computers used by UK astronomers; a collection of programs for the calibration and analysis of astronomical data; a team of people giving hardware, software and administrative support. The Starlink Project has been in operation since 1980 to provide UK astronomers with interactive image processing and data reduction facilities. There are now Starlink computer systems at 25 UK locations, serving about 1500 registered users. The Starlink software collection now has about 25 major packages covering a wide range of astronomical data reduction and analysis techniques, as well as many smaller programs and utilities. At the core of most of the packages is a common `software environment', which provides many of the functions which applications need and offers standardized methods of structuring and accessing data. The software environment simplifies programming and support, and makes it easy to use different packages for different stages of the data reduction. Users see a consistent style, and can mix applications without hitting problems of differing data formats. The Project group coordinates the writing and distribution of this software collection, which is Unix based. Outside the UK, Starlink is used at a large number of places, which range from installations at major UK telescopes, which are Starlink-compatible and managed like Starlink sites, to individuals who run only small parts of the Starlink software collection.

  18. Operation manual for EDXRDDA - a software package for Bragg peak analysis of energy dispersive powder X-ray diffraction data

    International Nuclear Information System (INIS)

    Jayaswal, Balhans; Vijaykumar, V.; Momin, S.N.; Sikka, S.K.

    1992-01-01

    EDXRDDA is a software package for analysis of raw data for energy dispersive x-ray diffraction from powder samples. It resolves the spectra into individual peaks by a constrained non-linear least squares method (Hughes and Sexton, 1988). The profile function adopted is the Gaussian/Lorentzian product with the mixing ratio refinable in the program. The program is implemented on an IBM PC and is highly interactive with extensive plotting facilities. This report is a user's guide for running the program. In the first step after inputting the spectra, the full spectra is plotted on the screen. The user then chooses a portion of this for peak resolution. The initial guess for the peak intensity, peak position are input with the help of a cursor or a mouse. Upto twenty peaks can be fitted at a time in an interval of 500 channels. For overlapping peaks, various constraints can be applied. Bragg peaks and fluorescence peaks with different half widths can be handled simultaneously. The program on execution produces a look up table which contains the refined values of the peak position, half width, peak intensity, integrated intensity, and their error estimates of each peak. The program is very general and can also be used for curve fitting of data from many other experiments. (author). 2 refs., 7 figs., 2 appendices

  19. Effect of high pressure processing on reduction of Listeria monocytogenes in packaged Queso Fresco

    Science.gov (United States)

    The effect of high hydrostatic pressure processing (HPP) on the survival of a five-strain rifampicin-resistant cocktail of Listeria monocytogenes in Queso Fresco (QF) was evaluated as a post-packaging intervention. QF was made using pasteurized, homogenized milk, was starter-free and was not pressed...

  20. Melanie II--a third-generation software package for analysis of two-dimensional electrophoresis images: I. Features and user interface.

    Science.gov (United States)

    Appel, R D; Palagi, P M; Walther, D; Vargas, J R; Sanchez, J C; Ravier, F; Pasquali, C; Hochstrasser, D F

    1997-12-01

    Although two-dimensional electrophoresis (2-DE) computer analysis software packages have existed ever since 2-DE technology was developed, it is only now that the hardware and software technology allows large-scale studies to be performed on low-cost personal computers or workstations, and that setting up a 2-DE computer analysis system in a small laboratory is no longer considered a luxury. After a first attempt in the seventies and early eighties to develop 2-DE analysis software systems on hardware that had poor or even no graphical capabilities, followed in the late eighties by a wave of innovative software developments that were possible thanks to new graphical interface standards such as XWindows, a third generation of 2-DE analysis software packages has now come to maturity. It can be run on a variety of low-cost, general-purpose personal computers, thus making the purchase of a 2-DE analysis system easily attainable for even the smallest laboratory that is involved in proteome research. Melanie II 2-D PAGE, developed at the University Hospital of Geneva, is such a third-generation software system for 2-DE analysis. Based on unique image processing algorithms, this user-friendly object-oriented software package runs on multiple platforms, including Unix, MS-Windows 95 and NT, and Power Macintosh. It provides efficient spot detection and quantitation, state-of-the-art image comparison, statistical data analysis facilities, and is Internet-ready. Linked to proteome databases such as those available on the World Wide Web, it represents a valuable tool for the "Virtual Lab" of the post-genome area.

  1. Modelled Cost-Effectiveness of a Package Size Cap and a Kilojoule Reduction Intervention to Reduce Energy Intake from Sugar-Sweetened Beverages in Australia

    Science.gov (United States)

    Mantilla Herrera, Ana Maria; Neal, Bruce; Zheng, Miaobing; Lal, Anita; Sacks, Gary

    2017-01-01

    Interventions targeting portion size and energy density of food and beverage products have been identified as a promising approach for obesity prevention. This study modelled the potential cost-effectiveness of: a package size cap on single-serve sugar sweetened beverages (SSBs) >375 mL (package size cap), and product reformulation to reduce energy content of packaged SSBs (energy reduction). The cost-effectiveness of each intervention was modelled for the 2010 Australia population using a multi-state life table Markov model with a lifetime time horizon. Long-term health outcomes were modelled from calculated changes in body mass index to their impact on Health-Adjusted Life Years (HALYs). Intervention costs were estimated from a limited societal perspective. Cost and health outcomes were discounted at 3%. Total intervention costs estimated in AUD 2010 were AUD 210 million. Both interventions resulted in reduced mean body weight (package size cap: 0.12 kg; energy reduction: 0.23 kg); and HALYs gained (package size cap: 73,883; energy reduction: 144,621). Cost offsets were estimated at AUD 750.8 million (package size cap) and AUD 1.4 billion (energy reduction). Cost-effectiveness analyses showed that both interventions were “dominant”, and likely to result in long term cost savings and health benefits. A package size cap and kJ reduction of SSBs are likely to offer excellent “value for money” as obesity prevention measures in Australia. PMID:28878175

  2. Accuracy evaluation of fusion of CT, MR, and SPECT images using commercially available software packages (SRS PLATO and IFS)

    International Nuclear Information System (INIS)

    Mongioj, Valeria; Brusa, Anna; Loi, Gianfranco; Pignoli, Emanuele; Gramaglia, Alberto; Scorsetti, Marta; Bombardieri, Emilio; Marchesini, Renato

    1999-01-01

    Purpose: A problem for clinicians is to mentally integrate information from multiple diagnostic sources, such as computed tomography (CT), magnetic resonance (MR), and single photon emission computed tomography (SPECT), whose images give anatomic and metabolic information. Methods and Materials: To combine this different imaging procedure information, and to overlay correspondent slices, we used commercially available software packages (SRS PLATO and IFS). The algorithms utilize a fiducial-based coordinate system (or frame) with 3 N-shaped markers, which allows coordinate transformation of a clinical examination data set (9 spots for each transaxial section) to a stereotactic coordinate system. The N-shaped markers were filled with fluids visible in each modality (gadolinium for MR, calcium chloride for CT, and 99m Tc for SPECT). The frame is relocatable, in the different acquisition modalities, by means of a head holder to which a face mask is fixed so as to immobilize the patient. Position errors due to the algorithms were obtained by evaluating the stereotactic coordinates of five sources detectable in each modality. Results: SPECT and MR position errors due to the algorithms were evaluated with respect to CT: Δx was ≤ 0.9 mm for MR and ≤ 1.4 mm for SPECT, Δy was ≤ 1 mm and ≤ 3 mm for MR and SPECT, respectively. Maximal differences in distance between estimated and actual fiducial centers (geometric mismatch) were in the order of the pixel size (0.8 mm for CT, 1.4 mm for MR, and 1.8 mm for SPECT). In an attempt to distinguish necrosis from residual disease, the image fusion protocol was studied in 35 primary or metastatic brain tumor patients. Conclusions: The image fusion technique has a good degree of accuracy as well as the potential to improve the specificity of tissue identification and the precision of the subsequent treatment planning

  3. An evaluation of the psychometric properties of the Purdue Pharmacist Directive Guidance Scale using SPSS and R software packages.

    Science.gov (United States)

    Marr-Lyon, Lisa R; Gupchup, Gireesh V; Anderson, Joe R

    2012-01-01

    The Purdue Pharmacist Directive Guidance (PPDG) Scale was developed to assess patients' perceptions of the level of pharmacist-provided (1) instruction and (2) feedback and goal-setting-2 aspects of pharmaceutical care. Calculations of its psychometric properties stemming from SPSS and R were similar, but distinct differences were apparent. Using SPSS and R software packages, researchers aimed to examine the construct validity of the PPDG using a higher order factoring procedure; in tandem, McDonald's omega and Cronbach's alpha were calculated as means of reliability analyses. Ninety-nine patients with either type I or type II diabetes, aged 18 years or older, able to read and write English, and who could provide written-informed consent participated in the study. Data were collected in 8 community pharmacies in New Mexico. Using R, (1) a principal axis factor analysis with promax (oblique) rotation was conducted, (2) a Schmid-Leiman transformation was attained, and (3) McDonald's omega and Cronbach's alpha were computed. Using SPSS, subscale findings were validated by conducting a principal axis factor analysis with promax rotation; strict parallels and Cronbach's alpha reliabilities were calculated. McDonald's omega and Cronbach's alpha were robust, with coefficients greater than 0.90; principal axis factor analysis with promax rotation revealed construct similarities with an overall general factor emerging from R. Further subjecting the PPDG to rigorous psychometric testing revealed stronger quantitative support of the overall general factor of directive guidance and subscales of instruction and feedback and goal-setting. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. The Modularized Software Package ASKI - Full Waveform Inversion Based on Waveform Sensitivity Kernels Utilizing External Seismic Wave Propagation Codes

    Science.gov (United States)

    Schumacher, F.; Friederich, W.

    2015-12-01

    We present the modularized software package ASKI which is a flexible and extendable toolbox for seismic full waveform inversion (FWI) as well as sensitivity or resolution analysis operating on the sensitivity matrix. It utilizes established wave propagation codes for solving the forward problem and offers an alternative to the monolithic, unflexible and hard-to-modify codes that have typically been written for solving inverse problems. It is available under the GPL at www.rub.de/aski. The Gauss-Newton FWI method for 3D-heterogeneous elastic earth models is based on waveform sensitivity kernels and can be applied to inverse problems at various spatial scales in both Cartesian and spherical geometries. The kernels are derived in the frequency domain from Born scattering theory as the Fréchet derivatives of linearized full waveform data functionals, quantifying the influence of elastic earth model parameters on the particular waveform data values. As an important innovation, we keep two independent spatial descriptions of the earth model - one for solving the forward problem and one representing the inverted model updates. Thereby we account for the independent needs of spatial model resolution of forward and inverse problem, respectively. Due to pre-integration of the kernels over the (in general much coarser) inversion grid, storage requirements for the sensitivity kernels are dramatically reduced.ASKI can be flexibly extended to other forward codes by providing it with specific interface routines that contain knowledge about forward code-specific file formats and auxiliary information provided by the new forward code. In order to sustain flexibility, the ASKI tools must communicate via file output/input, thus large storage capacities need to be accessible in a convenient way. Storing the complete sensitivity matrix to file, however, permits the scientist full manual control over each step in a customized procedure of sensitivity/resolution analysis and full

  5. CT and MR perfusion can discriminate severe cerebral hypoperfusion from perfusion absence: evaluation of different commercial software packages by using digital phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Uwano, Ikuko; Kudo, Kohsuke; Sasaki, Makoto [Iwate Medical University, Advanced Medical Research Center, Morioka (Japan); Christensen, Soren [University of Melbourne, Royal Melbourne Hospital, Departments of Neurology and Radiology, Victoria (Australia); Oestergaard, Leif [Aarhus University Hospital, Department of Neuroradiology, Center for Functionally Integrative Neuroscience, DK, Aarhus C (Denmark); Ogasawara, Kuniaki; Ogawa, Akira [Iwate Medical University, Department of Neurosurgery, Morioka (Japan)

    2012-05-15

    Computed tomography perfusion (CTP) and magnetic resonance perfusion (MRP) are expected to be usable for ancillary tests of brain death by detection of complete absence of cerebral perfusion; however, the detection limit of hypoperfusion has not been determined. Hence, we examined whether commercial software can visualize very low cerebral blood flow (CBF) and cerebral blood volume (CBV) by creating and using digital phantoms. Digital phantoms simulating 0-4% of normal CBF (60 mL/100 g/min) and CBV (4 mL/100 g/min) were analyzed by ten software packages of CT and MRI manufacturers. Region-of-interest measurements were performed to determine whether there was a significant difference between areas of 0% and areas of 1-4% of normal flow. The CTP software detected hypoperfusion down to 2-3% in CBF and 2% in CBV, while the MRP software detected that of 1-3% in CBF and 1-4% in CBV, although the lower limits varied among software packages. CTP and MRP can detect the difference between profound hypoperfusion of <5% from that of 0% in digital phantoms, suggesting their potential efficacy for assessing brain death. (orig.)

  6. A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: What is the minimum increase in size to detect growth in repeated CT examinations

    International Nuclear Information System (INIS)

    Hoop, Bartjan de; Gietema, Hester; Prokop, Mathias; Ginneken, Bram van; Zanen, Pieter; Groenewegen, Gerard

    2009-01-01

    We compared interexamination variability of CT lung nodule volumetry with six currently available semi-automated software packages to determine the minimum change needed to detect the growth of solid lung nodules. We had ethics committee approval. To simulate a follow-up examination with zero growth, we performed two low-dose unenhanced CT scans in 20 patients referred for pulmonary metastases. Between examinations, patients got off and on the table. Volumes of all pulmonary nodules were determined on both examinations using six nodule evaluation software packages. Variability (upper limit of the 95% confidence interval of the Bland-Altman plot) was calculated for nodules for which segmentation was visually rated as adequate. We evaluated 214 nodules (mean diameter 10.9 mm, range 3.3 mm-30.0 mm). Software packages provided adequate segmentation in 71% to 86% of nodules (p < 0.001). In case of adequate segmentation, variability in volumetry between scans ranged from 16.4% to 22.3% for the various software packages. Variability with five to six software packages was significantly less for nodules ≥8 mm in diameter (range 12.9%-17.1%) than for nodules <8 mm (range 18.5%-25.6%). Segmented volumes of each package were compared to each of the other packages. Systematic volume differences were detected in 11/15 comparisons. This hampers comparison of nodule volumes between software packages. (orig.)

  7. Operating cost estimate low-level radioactive waste volume reduction and packaging options

    International Nuclear Information System (INIS)

    Williams, P.C.; Collins, E.G.

    1983-01-01

    The projected operating cost data examine the differences in compaction and incineration for DAW. Two commonly achieved densities for compaction are presented, while a third case approaching the theoretical density of the cloth and paper materials shows the interesting possibilities of improved compaction. Incineration at two benchmarks for the chlorinated plastic component of typical DAW illustrates the impact waste stream make-up has on economics. Evaporator concentrates are considered as a liquid at four concentrations (6%, 12%, 25% and 50%) and after all water has been removed for the cement and polymer cases. Five separate processing schemes are presented for bead resins. These range from dewatering and packaging in high integrity containers to incineration with solidification

  8. Desktop mapping using GPS. SAHTI - a software package for environmental monitoring. Report on task JNTB898 on the Finnish support programme to IAEA safeguards

    Energy Technology Data Exchange (ETDEWEB)

    Ilander, T; Kansanaho, A; Toivonen, H

    1996-02-01

    Environmental sampling is the key method of the IAEA in searching signatures of a covert nuclear programme. However, it is not always easy to know the exact location of the sampling site. The satellite navigation system, utilizing a small receiver (GPS) and a PC, allows to have independent positioning data easily. The present task on the Finnish Support Programme was launched to create software to merge information about sampling and positioning. The system is build above a desktop mapping software package. However, the result of the development goes beyond the initial goal: the software can be used to real- time positioning in a mobile unit utilizing maps that can be purchased or produced by the user. In addition, the system can be easily enlarged to visualize data in real time from mobile environmental monitors, such as a Geiger counter, a pressurized ionisation chamber of a gamma-ray spectrometer. (orig.) (7 figs.).

  9. Desktop mapping using GPS. SAHTI - a software package for environmental monitoring. Report on task JNTB898 on the Finnish support programme to IAEA safeguards

    International Nuclear Information System (INIS)

    Ilander, T.; Kansanaho, A.; Toivonen, H.

    1996-02-01

    Environmental sampling is the key method of the IAEA in searching signatures of a covert nuclear programme. However, it is not always easy to know the exact location of the sampling site. The satellite navigation system, utilizing a small receiver (GPS) and a PC, allows to have independent positioning data easily. The present task on the Finnish Support Programme was launched to create software to merge information about sampling and positioning. The system is build above a desktop mapping software package. However, the result of the development goes beyond the initial goal: the software can be used to real- time positioning in a mobile unit utilizing maps that can be purchased or produced by the user. In addition, the system can be easily enlarged to visualize data in real time from mobile environmental monitors, such as a Geiger counter, a pressurized ionisation chamber of a gamma-ray spectrometer. (orig.) (7 figs.)

  10. BASTILLE - Better Analysis Software to Treat ILL Experiments - a unified, unifying approach to data reduction and analysis

    International Nuclear Information System (INIS)

    Johnson, M.

    2011-01-01

    Data reduction and analysis is a key component in the production of scientific results. If this component, like any other in the chain, is weak, the final output is compromised. The current situation for data reduction and analysis may be regarded as adequate, but it is variable, depending on the instrument, and should be improved. In particular the delivery of new and upgraded instruments in Millennium Phase I and those proposed for Phase II will bring new demands and challenges for software development. Failure to meet these challenges will hamper the exploitation of higher data rates and the delivery of new science. The proposed project is to provide a single, underpinning software infrastructure for data analysis, which would ensure: 1) a clear vision of software provision at ILL; 2) a clear role for the 'Computing for Science' Group (CS) in maintaining and developing the infrastructure and the codes; 3) a well-defined framework for recruiting and training CS staff; 4) ease and efficiency of development within a common, well-defined software environment; 5) safeguarding of key, existing software; and 6) ease of communication with other software like instrument control software to allow real-time data analysis and experiment control, or software from other institutes or sources

  11. Electromagnetic interference reduction using electromagnetic bandgap structures in packages, enclosures, cavities, and antennas

    Science.gov (United States)

    Mohajer Iravani, Baharak

    Electromagnetic interference (EMI) is a source of noise problems in electronic devices. The EMI is attributed to coupling between sources of radiation and components placed in the same media such as package or chassis. This coupling can be either through conducting currents or through radiation. The radiation of electromagnetic (EM) fields is supported by surface currents. Thus, minimizing these surface currents is considered a major and critical step to suppress EMI. In this work, we present novel strategies to confine surface currents in different applications including packages, enclosures, cavities, and antennas. The efficiency of present methods of EM noise suppression is limited due to different drawbacks. For example, the traditional use of lossy materials and absorbers suffers from considerable disadvantages including mechanical and thermal reliability leading to limited life time, cost, volume, and weight. In this work, we consider the use of Electromagnetic Band Gap (EBG) structures. These structures are suitable for suppressing surface currents within a frequency band denoted as the bandgap. Their design is straight forward, they are inexpensive to implement, and they do not suffer from the limitations of the previous methods. A new method of EM noise suppression in enclosures and cavity-backed antennas using mushroom-type EBG structures is introduced. The effectiveness of the EBG as an EMI suppresser is demonstrated using numerical simulations and experimental measurements. To allow integration of EBGs in printed circuit boards and packages, novel miniaturized simple planar EBG structures based on use of high-k dielectric material (epsilonr > 100) are proposed. The design consists of meander lines and patches. The inductive meander lines serve to provide current continuity bridges between the capacitive patches. The high-k dielectric material increases the effective capacitive load substantially in comparison to commonly used material with much lower

  12. PC-CIMACT. A near real time materials accountancy software package for use on an IBM or compatible PC

    International Nuclear Information System (INIS)

    Williams, D.E.; Gale, R.

    1990-03-01

    This report describes the 'PC-CIMACT' Near Real Time Materials Accountancy computer package. It has been derived from 'CIMACT', which is in daily use at the UKAEA's Dounreay Nuclear Power Establishment. The scope of the package is presented, together with the statistical analyses it encompasses. Several of the analyses are illustrated by the treatment of data from a simulated reprocessing campaign. A user guide providing detailed instructions is also included. (author)

  13. The Next Generation in Subsidence and Aquifer-System Compaction Modeling within the MODFLOW Software Family: A New Package for MODFLOW-2005 and MODFLOW-OWHM

    Science.gov (United States)

    Boyce, S. E.; Leake, S. A.; Hanson, R. T.; Galloway, D. L.

    2015-12-01

    The Subsidence and Aquifer-System Compaction Packages, SUB and SUB-WT, for MODFLOW are two currently supported subsidence packages within the MODFLOW family of software. The SUB package allows the calculation of instantaneous and delayed releases of water from distributed interbeds (relatively more compressible fine-grained sediments) within a saturated aquifer system or discrete confining beds. The SUB-WT package does not include delayed releases, but does perform a more rigorous calculation of vertical stresses that can vary the effective stress that causes compaction. This calculation of instantaneous compaction can include the effect of water-table fluctuations for unconfined aquifers on effective stress, and can optionally adjust the elastic and inelastic storage properties based on the changes in effective stress. The next generation of subsidence modeling in MODFLOW is under development, and will merge and enhance the capabilities of the SUB and SUB-WT Packages for MODFLOW-2005 and MODFLOW-OWHM. This new version will also provide some additional features such as stress dependent vertical hydraulic conductivity of interbeds, time-varying geostatic loads, and additional attributes related to aquifer-system compaction and subsidence that will broaden the class of problems that can be simulated. The new version will include a redesigned source code, a new user friendly input file structure, more output options, and new subsidence solution options. This presentation will discuss progress in developing the new package and the new features being implemented and their potential applications. By Stanley Leake, Scott E. Boyce, Randall T. Hanson, and Devin Galloway

  14. PAINeT: An object-oriented software package for simulations of flow-field, transport coefficients and flux terms in non-equilibrium gas mixture flows

    Science.gov (United States)

    Istomin, V. A.

    2018-05-01

    The software package Planet Atmosphere Investigator of Non-equilibrium Thermodynamics (PAINeT) has been devel-oped for studying the non-equilibrium effects associated with electronic excitation, chemical reactions and ionization. These studies are necessary for modeling process in shock tubes, in high enthalpy flows, in nozzles or jet engines, in combustion and explosion processes, in modern plasma-chemical and laser technologies. The advantages and possibilities of the package implementation are stated. Within the framework of the package implementation, based on kinetic theory approximations (one-temperature and state-to-state approaches), calculations are carried out, and the limits of applicability of a simplified description of shock-heated air flows and any other mixtures chosen by the user are given. Using kinetic theory algorithms, a numerical calculation of the heat fluxes and relaxation terms can be performed, which is necessary for further comparison of engineering simulation with experi-mental data. The influence of state-to-state distributions over electronic energy levels on the coefficients of thermal conductivity, diffusion, heat fluxes and diffusion velocities of the components of various gas mixtures behind shock waves is studied. Using the software package the accuracy of different approximations of the kinetic theory of gases is estimated. As an example state-resolved atomic ionized mixture of N/N+/O/O+/e- is considered. It is shown that state-resolved diffusion coefficients of neutral and ionized species vary from level to level. Comparing results of engineering applications with those given by PAINeT, recommendations for adequate models selection are proposed.

  15. SERPent: Automated reduction and RFI-mitigation software for e-MERLIN

    Science.gov (United States)

    Peck, Luke W.; Fenech, Danielle M.

    2013-08-01

    The Scripted E-merlin Rfi-mitigation PipelinE for iNTerferometry (SERPent) is an automated reduction and RFI-mitigation procedure utilising the SumThreshold methodology (Offringa et al., 2010a), originally developed for the LOFAR pipeline. SERPent is written in the Parseltongue language enabling interaction with the Astronomical Image Processing Software (AIPS) program. Moreover, SERPent is a simple 'out of the box' Python script, which is easy to set up and is free of compilers. In addition to the flagging of RFI affected visibilities, the script also flags antenna zero-amplitude dropouts and Lovell telescope phase calibrator stationary scans inherent to the e-MERLIN system. Both the flagging and computational performances of SERPent are presented here, for e-MERLIN commissioning datasets for both L-band (1.3-1.8 GHz) and C-band (4-8 GHz) observations. RFI typically amounts to future interferometers such as the SKA and the associated pathfinders (MeerKAT and ASKAP), where the vast data sizes (>TB) make traditional astronomer interactions unfeasible.

  16. ORBS: A data reduction software for the imaging Fourier transform spectrometers SpIOMM and SITELLE

    Science.gov (United States)

    Martin, T.; Drissen, L.; Joncas, G.

    2012-09-01

    SpIOMM (Spectromètre-Imageur de l'Observatoire du Mont Mégantic) is still the only operational astronomical Imaging Fourier Transform Spectrometer (IFTS) capable of obtaining the visible spectrum of every source of light in a field of view of 12 arc-minutes. Even if it has been designed to work with both outputs of the Michelson interferometer, up to now only one output has been used. Here we present ORBS (Outils de Réduction Binoculaire pour SpIOMM/SITELLE), the reduction software we designed in order to take advantage of the two output data. ORBS will also be used to reduce the data of SITELLE (Spectromètre-Imageur pour l' Étude en Long et en Large des raies d' Émissions) { the direct successor of SpIOMM, which will be in operation at the Canada-France- Hawaii Telescope (CFHT) in early 2013. SITELLE will deliver larger data cubes than SpIOMM (up to 2 cubes of 34 Go each). We thus have made a strong effort in optimizing its performance efficiency in terms of speed and memory usage in order to ensure the best compliance with the quality characteristics discussed with the CFHT team. As a result ORBS is now capable of reducing 68 Go of data in less than 20 hours using only 5 Go of random-access memory (RAM).

  17. A Test Set for stiff Initial Value Problem Solvers in the open source software R: Package deTestSet

    NARCIS (Netherlands)

    Mazzia, F.; Cash, J.R.; Soetaert, K.

    2012-01-01

    In this paper we present the R package deTestSet that includes challenging test problems written as ordinary differential equations (ODEs), differential algebraic equations (DAEs) of index up to 3 and implicit differential equations (IDES). In addition it includes 6 new codes to solve initial value

  18. RARtool: A MATLAB Software Package for Designing Response-Adaptive Randomized Clinical Trials with Time-to-Event Outcomes.

    Science.gov (United States)

    Ryeznik, Yevgen; Sverdlov, Oleksandr; Wong, Weng Kee

    2015-08-01

    Response-adaptive randomization designs are becoming increasingly popular in clinical trial practice. In this paper, we present RARtool , a user interface software developed in MATLAB for designing response-adaptive randomized comparative clinical trials with censored time-to-event outcomes. The RARtool software can compute different types of optimal treatment allocation designs, and it can simulate response-adaptive randomization procedures targeting selected optimal allocations. Through simulations, an investigator can assess design characteristics under a variety of experimental scenarios and select the best procedure for practical implementation. We illustrate the utility of our RARtool software by redesigning a survival trial from the literature.

  19. pyLIMA: An Open-source Package for Microlensing Modeling. I. Presentation of the Software and Analysis of Single-lens Models

    Science.gov (United States)

    Bachelet, E.; Norbury, M.; Bozza, V.; Street, R.

    2017-11-01

    Microlensing is a unique tool, capable of detecting the “cold” planets between ˜1 and 10 au from their host stars and even unbound “free-floating” planets. This regime has been poorly sampled to date owing to the limitations of alternative planet-finding methods, but a watershed in discoveries is anticipated in the near future thanks to the planned microlensing surveys of WFIRST-AFTA and Euclid's Extended Mission. Of the many challenges inherent in these missions, the modeling of microlensing events will be of primary importance, yet it is often time-consuming, complex, and perceived as a daunting barrier to participation in the field. The large scale of future survey data products will require thorough but efficient modeling software, but, unlike other areas of exoplanet research, microlensing currently lacks a publicly available, well-documented package to conduct this type of analysis. We present version 1.0 of the python Lightcurve Identification and Microlensing Analysis (pyLIMA). This software is written in Python and uses existing packages as much as possible to make it widely accessible. In this paper, we describe the overall architecture of the software and the core modules for modeling single-lens events. To verify the performance of this software, we use it to model both real data sets from events published in the literature and generated test data produced using pyLIMA's simulation module. The results demonstrate that pyLIMA is an efficient tool for microlensing modeling. We will expand pyLIMA to consider more complex phenomena in the following papers.

  20. Some design constraints required for the use of generic software in embedded systems: Packages which manage abstract dynamic structures without the need for garbage collection

    Science.gov (United States)

    Johnson, Charles S.

    1986-01-01

    The embedded systems running real-time applications, for which Ada was designed, require their own mechanisms for the management of dynamically allocated storage. There is a need for packages which manage their own internalo structures to control their deallocation as well, due to the performance implications of garbage collection by the KAPSE. This places a requirement upon the design of generic packages which manage generically structured private types built-up from application-defined input types. These kinds of generic packages should figure greatly in the development of lower-level software such as operating systems, schedulers, controllers, and device driver; and will manage structures such as queues, stacks, link-lists, files, and binary multary (hierarchical) trees. Controlled to prevent inadvertent de-designation of dynamic elements, which is implicit in the assignment operation A study was made of the use of limited private type, in solving the problems of controlling the accumulation of anonymous, detached objects in running systems. The use of deallocator prodecures for run-down of application-defined input types during deallocation operations during satellites.

  1. METEOR v1.0 - Design and structure of the software package; METEOR v1.0 - Estructura y modulos informaticos

    Energy Technology Data Exchange (ETDEWEB)

    Palomo, E.

    1994-07-01

    This script describes the structure and the separated modules of the software package METEOR for the statistical analysis of meteorological data series. It contains a systematic description of the subroutines of METEOR and, also, of the required shape for input and output files. The original version of METEOR have been developed by Ph.D. Elena Palomo, CIEMAT-IER, GIMASE. It is built by linking programs and routines written in FORTRAN 77 and it adds thc graphical capabilities of GNUPLOT. The shape of this toolbox was designed following the criteria of modularity, flexibility and agility criteria. All the input, output and analysis options are structured in three main menus: i) the first is aimed to evaluate the quality of the data set; ii) the second is aimed for pre-processing of the data; and iii) the third is aimed towards the statistical analyses and for creating the graphical outputs. Actually the information about METEOR is constituted by three documents written in spanish: 1) METEOR v1.0: User's guide; 2) METEOR v1.0: A usage example; 3) METEOR v 1.0: Design and structure of the software package. (Author)

  2. A software package to construct polynomial sets over Z2 for determining the output of quantum computations

    International Nuclear Information System (INIS)

    Gerdt, Vladimir P.; Severyanov, Vasily M.

    2006-01-01

    A C package is presented that allows a user for an input quantum circuit to generate a set of multivariate polynomials over the finite field Z 2 whose total number of solutions in Z 2 determines the output of the quantum computation defined by the circuit. The generated polynomial system can further be converted to the canonical Grobner basis form which provides a universal algorithmic tool for counting the number of common roots of the polynomials

  3. ATLAS software configuration and build tool optimisation

    Science.gov (United States)

    Rybkin, Grigory; Atlas Collaboration

    2014-06-01

    ATLAS software code base is over 6 million lines organised in about 2000 packages. It makes use of some 100 external software packages, is developed by more than 400 developers and used by more than 2500 physicists from over 200 universities and laboratories in 6 continents. To meet the challenge of configuration and building of this software, the Configuration Management Tool (CMT) is used. CMT expects each package to describe its build targets, build and environment setup parameters, dependencies on other packages in a text file called requirements, and each project (group of packages) to describe its policies and dependencies on other projects in a text project file. Based on the effective set of configuration parameters read from the requirements files of dependent packages and project files, CMT commands build the packages, generate the environment for their use, or query the packages. The main focus was on build time performance that was optimised within several approaches: reduction of the number of reads of requirements files that are now read once per package by a CMT build command that generates cached requirements files for subsequent CMT build commands; introduction of more fine-grained build parallelism at package task level, i.e., dependent applications and libraries are compiled in parallel; code optimisation of CMT commands used for build; introduction of package level build parallelism, i. e., parallelise the build of independent packages. By default, CMT launches NUMBER-OF-PROCESSORS build commands in parallel. The other focus was on CMT commands optimisation in general that made them approximately 2 times faster. CMT can generate a cached requirements file for the environment setup command, which is especially useful for deployment on distributed file systems like AFS or CERN VMFS. The use of parallelism, caching and code optimisation significantly-by several times-reduced software build time, environment setup time, increased the efficiency of

  4. The SCEC Broadband Platform: A Collaborative Open-Source Software Package for Strong Ground Motion Simulation and Validation

    Science.gov (United States)

    Silva, F.; Maechling, P. J.; Goulet, C. A.; Somerville, P.; Jordan, T. H.

    2014-12-01

    The Southern California Earthquake Center (SCEC) Broadband Platform is a collaborative software development project involving geoscientists, earthquake engineers, graduate students, and the SCEC Community Modeling Environment. The SCEC Broadband Platform (BBP) is open-source scientific software that can generate broadband (0-100Hz) ground motions for earthquakes, integrating complex scientific modules that implement rupture generation, low and high-frequency seismogram synthesis, non-linear site effects calculation, and visualization into a software system that supports easy on-demand computation of seismograms. The Broadband Platform operates in two primary modes: validation simulations and scenario simulations. In validation mode, the Platform runs earthquake rupture and wave propagation modeling software to calculate seismograms for a well-observed historical earthquake. Then, the BBP calculates a number of goodness of fit measurements that quantify how well the model-based broadband seismograms match the observed seismograms for a certain event. Based on these results, the Platform can be used to tune and validate different numerical modeling techniques. In scenario mode, the Broadband Platform can run simulations for hypothetical (scenario) earthquakes. In this mode, users input an earthquake description, a list of station names and locations, and a 1D velocity model for their region of interest, and the Broadband Platform software then calculates ground motions for the specified stations. Working in close collaboration with scientists and research engineers, the SCEC software development group continues to add new capabilities to the Broadband Platform and to release new versions as open-source scientific software distributions that can be compiled and run on many Linux computer systems. Our latest release includes 5 simulation methods, 7 simulation regions covering California, Japan, and Eastern North America, the ability to compare simulation results

  5. Reduction of Listeria innocua contamination in vacuum-packaged dry-cured Italian pork products after high hydrostatic pressure treatment

    Directory of Open Access Journals (Sweden)

    Giuseppe Merialdi

    2015-06-01

    Full Text Available The present work aims to present the results of the application of a treatment with high hydrostatic pressure (HHP on Italian fermented and dry-cured pork products. The products used in this study were portioned cured ham, portioned bacon and salami, vacuumpackaged and produced by a single processing company. Two studies were conducted on a single batch of the three products by means of an artificial contamination with Listeria innocua as a surrogate of L. monocytogenes. In the first trial a superficial contamination was obtained by immersion for 3 min in the culture broth with a concentration of approximately 9 log cfu/mL. At the end of the inoculum step, the pieces were dred at room temperature and vacuum packaged. In the second trial 50 kg of minced pork meat were contaminated before production of salami. In both cases the inoculum contained 5 strains of L. innocua. Subsequently, in both trials, 10 samples were randomly divided into two groups of 5 pieces each: i TH group, samples treated with HHP; ii group C, control samples, not subjected to any treatment. All samples were stored at refrigeration temperature at the end of HHP treatments (if applied, and analyzed for the determination of the surface (1st trial and deep (2nd trial quantitative contamination of L. innocua. pH and aW were also determined on 3 pieces of each products belonging to group C. The difference between the medians of the log cfu/cm2 or g established between controls and treated were compared using the non-parametric test (Kruskal-Wallis test with P<0.01. In all products and in both trials the level of contamination detected in treatment groups was always significantly lower than in controls (P<0.01. In particular, in vacuum-packaged ham, bacon and salami viability logarithmic viability reductions equal to -2.29, -2.54 and -2.51 were observed, respectively. This study aimed to evaluate a not-thermal treatment on Italian cured or fermented pork products. The results of

  6. Problems in Analyzing Time Series with Gaps and Their Solution with the WinABD Software Package

    Science.gov (United States)

    Desherevskii, A. V.; Zhuravlev, V. I.; Nikolsky, A. N.; Sidorin, A. Ya.

    2017-12-01

    Technologies for the analysis of time series with gaps are considered. Some algorithms of signal extraction (purification) and evaluation of its characteristics, such as rhythmic components, are discussed for series with gaps. Examples are given for the analysis of data obtained during long-term observations at the Garm geophysical test site and in other regions. The technical solutions used in the WinABD software are considered to most efficiently arrange the operation of relevant algorithms in the presence of observational defects.

  7. Software Reviews.

    Science.gov (United States)

    Dwyer, Donna; And Others

    1989-01-01

    Reviewed are seven software packages for Apple and IBM computers. Included are: "Toxicology"; "Science Corner: Space Probe"; "Alcohol and Pregnancy"; "Science Tool Kit Plus"; Computer Investigations: Plant Growth"; "Climatrolls"; and "Animal Watch: Whales." (CW)

  8. Application of a statistical software package for analysis of large patient dose data sets obtained from RIS

    International Nuclear Information System (INIS)

    Fazakerley, J.; Charnock, P.; Wilde, R.; Jones, R.; Ward, M.

    2010-01-01

    For the purpose of patient dose audit, clinical audit and radiology workload analysis, data from Radiology Information Systems (RIS) at many hospitals are collected using a database and the analysis was automated using a statistical package and Visual Basic coding. The database is a Structured Query Language database, which can be queried using an off-the-shelf statistical package, Statistica. Macros were created to automatically format the data to a consistent format between different hospitals ready for analysis. These macros can also be used to automate further analysis such as detailing mean kV, mAs and entrance surface dose per room and per gender. Standard deviation and standard error of the mean are also generated. Graphs can also be generated to illustrate the trends in doses between different variables such as room and gender. Collectively, this information can be used to generate a report. A process that once could take up to 1 d to complete now takes around 1 h. A major benefit in providing the service to hospital trusts is that less resource is now required to report on RIS data, making the possibility of continuous dose audit more likely. Time that was spent on sorting through data can now be spent on improving the analysis to provide benefit to the customer. Using data sets from RIS is a good way to perform dose audits as the huge numbers of data available provide the bases for very accurate analysis. Using macros written in Statistica Visual Basic has helped sort and consistently analyse these data. Being able to analyse by exposure factors has provided a more detailed report to the customer. (authors)

  9. CIRCE2/DEKGEN2: A software package for facilitated optical analysis of 3-D distributed solar energy concentrators. Theory and user manual

    Energy Technology Data Exchange (ETDEWEB)

    Romero, V.J.

    1994-03-01

    CIRCE2 is a computer code for modeling the optical performance of three-dimensional dish-type solar energy concentrators. Statistical methods are used to evaluate the directional distribution of reflected rays from any given point on the concentrator. Given concentrator and receiver geometries, sunshape (angular distribution of incident rays from the sun), and concentrator imperfections such as surface roughness and random deviation in slope, the code predicts the flux distribution and total power incident upon the target. Great freedom exists in the variety of concentrator and receiver configurations that can be modeled. Additionally, provisions for shading and receiver aperturing are included.- DEKGEN2 is a preprocessor designed to facilitate input of geometry, error distributions, and sun models. This manual describes the optical model, user inputs, code outputs, and operation of the software package. A user tutorial is included in which several collectors are built and analyzed in step-by-step examples.

  10. Simulation of the target-oriented driving of an autonomous vehicle in a labyrinthic environment by means of the KISMET software package

    International Nuclear Information System (INIS)

    Knueppel, H.; Kuehnapfel, U.; Smidt, D.

    1991-10-01

    By using the special capabilities of the KISMET software-package and hardware for geometric operations and graphical presentation, an algorithm for the collision-free target-oriented driving of an autonomous vehicle was developed, implemented and linked to KISMET. The algorithm employs a simple global route-planner. It creates the global path neglecting the finite vehicle dimensions as input to the sensor-based local route-planner. The local planner for each time step transforms the sensor pattern, received by a number of ultrasonic sensors, to the movement-pattern. The target oriented global information influences the local operations. Some examples and a video demonstrate, the target will be reached collision free and close to the shortest path even in a labyrinthic environment. (orig.) [de

  11. DFTBaby: A software package for non-adiabatic molecular dynamics simulations based on long-range corrected tight-binding TD-DFT(B)

    Science.gov (United States)

    Humeniuk, Alexander; Mitrić, Roland

    2017-12-01

    A software package, called DFTBaby, is published, which provides the electronic structure needed for running non-adiabatic molecular dynamics simulations at the level of tight-binding DFT. A long-range correction is incorporated to avoid spurious charge transfer states. Excited state energies, their analytic gradients and scalar non-adiabatic couplings are computed using tight-binding TD-DFT. These quantities are fed into a molecular dynamics code, which integrates Newton's equations of motion for the nuclei together with the electronic Schrödinger equation. Non-adiabatic effects are included by surface hopping. As an example, the program is applied to the optimization of excited states and non-adiabatic dynamics of polyfluorene. The python and Fortran source code is available at http://www.dftbaby.chemie.uni-wuerzburg.de.

  12. A user's guide to the GoldSim/BLT-MS integrated software package:a low-level radioactive waste disposal performance assessment model

    International Nuclear Information System (INIS)

    Knowlton, Robert G.; Arnold, Bill Walter; Mattie, Patrick D.

    2007-01-01

    Sandia National Laboratories (Sandia), a U.S. Department of Energy National Laboratory, has over 30 years experience in the assessment of radioactive waste disposal and at the time of this publication is providing assistance internationally in a number of areas relevant to the safety assessment of radioactive waste disposal systems. In countries with small radioactive waste programs, international technology transfer program efforts are often hampered by small budgets, schedule constraints, and a lack of experienced personnel. In an effort to surmount these difficulties, Sandia has developed a system that utilizes a combination of commercially available software codes and existing legacy codes for probabilistic safety assessment modeling that facilitates the technology transfer and maximizes limited available funding. Numerous codes developed and endorsed by the United States Nuclear Regulatory Commission (NRC) and codes developed and maintained by United States Department of Energy are generally available to foreign countries after addressing import/export control and copyright requirements. From a programmatic view, it is easier to utilize existing codes than to develop new codes. From an economic perspective, it is not possible for most countries with small radioactive waste disposal programs to maintain complex software, which meets the rigors of both domestic regulatory requirements and international peer review. Therefore, revitalization of deterministic legacy codes, as well as an adaptation of contemporary deterministic codes, provides a credible and solid computational platform for constructing probabilistic safety assessment models. This document is a reference users guide for the GoldSim/BLT-MS integrated modeling software package developed as part of a cooperative technology transfer project between Sandia National Laboratories and the Institute of Nuclear Energy Research (INER) in Taiwan for the preliminary assessment of several candidate low

  13. PONDEROSA-C/S: client–server based software package for automated protein 3D structure determination

    OpenAIRE

    Lee, Woonghee; Stark, Jaime L.; Markley, John L.

    2014-01-01

    Peak-picking Of Noe Data Enabled by Restriction Of Shift Assignments-Client Server (PONDEROSA-C/S) builds on the original PONDEROSA software (Lee et al. in Bioinformatics 27:1727–1728. doi:10.1093/bioinformatics/btr200, 2011) and includes improved features for structure calculation and refinement. PONDEROSA-C/S consists of three programs: Ponderosa Server, Ponderosa Client, and Ponderosa Analyzer. PONDEROSA-C/S takes as input the protein sequence, a list of assigned chemical shifts, and nucle...

  14. Using a commercial mathematics software package for on-line analysis at the BNL Accelerator Test Facility

    International Nuclear Information System (INIS)

    Malone, R.; Wang, X.J.

    1999-01-01

    BY WRITING BOTH A CUSTOM WINDOWS(NTTM) DYNAMIC LINK LIBRARY AND GENERIC COMPANION SERVER SOFTWARE, THE INTRINSIC FUNCTIONS OF MATHSOFT MATHCAD(TM) HAVE BEEN EXTENDED WITH NEW CAPABILITIES WHICH PERMIT DIRECT ACCESS TO THE CONTROL SYSTEM DATABASES OF BROOKHAVEN NATIONAL LABORATORY ACCELERATOR TEST FACILITY. UNDER THIS SCHEME, A MATHCAD WORKSHEET EXECUTING ON A PERSONAL COMPUTER BECOMES A CLIENT WHICH CAN BOTH IMPORT AND EXPORT DATA TO A CONTROL SYSTEM SERVER VIA A NETWORK STREAM SOCKET CONNECTION. THE RESULT IS AN ALTERNATIVE, MATHEMATICALLY ORIENTED VIEW OF CONTROLLING THE ACCELERATOR INTERACTIVELY

  15. A Software Toolkit to Study Systematic Uncertainties of the Physics Models of the Geant4 Simulation Package

    Science.gov (United States)

    Genser, Krzysztof; Hatcher, Robert; Kelsey, Michael; Perdue, Gabriel; Wenzel, Hans; Wright, Dennis H.; Yarba, Julia

    2017-10-01

    The Geant4 simulation toolkit is used to model interactions between particles and matter. Geant4 employs a set of validated physics models that span a wide range of interaction energies. These models rely on measured cross-sections and phenomenological models with the physically motivated parameters that are tuned to cover many application domains. To study what uncertainties are associated with the Geant4 physics models we have designed and implemented a comprehensive, modular, user-friendly software toolkit that allows the variation of one or more parameters of one or more Geant4 physics models involved in simulation studies. It also enables analysis of multiple variants of the resulting physics observables of interest in order to estimate the uncertainties associated with the simulation model choices. Based on modern event-processing infrastructure software, the toolkit offers a variety of attractive features, e.g. flexible run-time configurable workflow, comprehensive bookkeeping, easy to expand collection of analytical components. Design, implementation technology, and key functionalities of the toolkit are presented in this paper and illustrated with selected results.

  16. Effective dose and organ doses estimation taking tube current modulation into account with a commercial software package

    International Nuclear Information System (INIS)

    Lopez-Rendon, X.; Bosmans, H.; Zanca, F.; Oyen, R.

    2015-01-01

    To evaluate the effect of including tube current modulation (TCM) versus using the average mAs in estimating organ and effective dose (E) using commercial software. Forty adult patients (24 females, 16 males) with normal BMI underwent chest/abdomen computed tomography (CT) performed with TCM at 120 kVp, reference mAs of 110 (chest) and 200 (abdomen). Doses to fully irradiated organs (breasts, lungs, stomach, liver and ovaries) and E were calculated using two versions of a dosimetry software: v.2.0, which uses the average mAs, and v.2.2, which accounts for TCM by implementing a gender-specific mAs profile. Student's t-test was used to assess statistically significant differences between organ doses calculated with the two versions. A statistically significant difference (p < 0.001) was found for E on chest and abdomen CT, with E being lower by 4.2 % when TCM is considered. Similarly, organ doses were also significantly lower (p < 0.001): 13.7 % for breasts, 7.3 % for lungs, 9.1 % for the liver and 8.5 % for the stomach. Only the dose to the ovaries was higher with TCM (11.5 %). When TCM is used, for the stylized phantom, the doses to lungs, breasts, stomach and liver decreased while the dose to the ovaries increased. (orig.)

  17. Effective dose and organ doses estimation taking tube current modulation into account with a commercial software package

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Rendon, X. [KU Leuven, Department of Imaging and Pathology, Division of Medical Physics and Quality Assessment, Herestraat 49, box 7003, Leuven (Belgium); Bosmans, H.; Zanca, F. [KU Leuven, Department of Imaging and Pathology, Division of Medical Physics and Quality Assessment, Herestraat 49, box 7003, Leuven (Belgium); University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Oyen, R. [University Hospitals Leuven, Department of Radiology, Leuven (Belgium)

    2015-07-15

    To evaluate the effect of including tube current modulation (TCM) versus using the average mAs in estimating organ and effective dose (E) using commercial software. Forty adult patients (24 females, 16 males) with normal BMI underwent chest/abdomen computed tomography (CT) performed with TCM at 120 kVp, reference mAs of 110 (chest) and 200 (abdomen). Doses to fully irradiated organs (breasts, lungs, stomach, liver and ovaries) and E were calculated using two versions of a dosimetry software: v.2.0, which uses the average mAs, and v.2.2, which accounts for TCM by implementing a gender-specific mAs profile. Student's t-test was used to assess statistically significant differences between organ doses calculated with the two versions. A statistically significant difference (p < 0.001) was found for E on chest and abdomen CT, with E being lower by 4.2 % when TCM is considered. Similarly, organ doses were also significantly lower (p < 0.001): 13.7 % for breasts, 7.3 % for lungs, 9.1 % for the liver and 8.5 % for the stomach. Only the dose to the ovaries was higher with TCM (11.5 %). When TCM is used, for the stylized phantom, the doses to lungs, breasts, stomach and liver decreased while the dose to the ovaries increased. (orig.)

  18. A Software Toolkit to Study Systematic Uncertainties of the Physics Models of the Geant4 Simulation Package

    CERN Document Server

    Genser, Krzysztof; Perdue, Gabriel; Wenzel, Hans; Yarba, Julia; Kelsey, Michael; Wright, Dennis H

    2016-01-01

    The Geant4 toolkit is used to model interactions between particles and matter. Geant4 employs a set of validated physics models that span a wide range of interaction energies. These models are tuned to cover a large variety of possible applications. This raises the critical question of what uncertainties are associated with the Geant4 physics model, or group of models, involved in a simulation project. To address the challenge, we have designed and implemented a comprehen- sive, modular, user-friendly software toolkit that allows the variation of one or more parameters of one or more Geant4 physics models involved in simulation studies. It also enables analysis of multiple variants of the resulting physics observables of interest in order to estimate the uncertain- ties associated with the simulation model choices. Key functionalities of the toolkit are presented in this paper and are illustrated with selected results.

  19. AR2, a novel automatic muscle artifact reduction software method for ictal EEG interpretation: Validation and comparison of performance with commercially available software [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Shennan Aibel Weiss

    2017-04-01

    Full Text Available Objective: To develop a novel software method (AR2 for reducing muscle contamination of ictal scalp electroencephalogram (EEG, and validate this method on the basis of its performance in comparison to a commercially available software method (AR1 to accurately depict seizure-onset location. Methods: A blinded investigation used 23 EEG recordings of seizures from 8 patients. Each recording was uninterpretable with digital filtering because of muscle artifact and processed using AR1 and AR2 and reviewed by 26 EEG specialists. EEG readers assessed seizure-onset time, lateralization, and region, and specified confidence for each determination. The two methods were validated on the basis of the number of readers able to render assignments, confidence, the intra-class correlation (ICC, and agreement with other clinical findings. Results: Among the 23 seizures, two-thirds of the readers were able to delineate seizure-onset time in 10 of 23 using AR1, and 15 of 23 using AR2 (p<0.01. Fewer readers could lateralize seizure-onset (p<0.05. The confidence measures of the assignments were low (probable-unlikely, but increased using AR2 (p<0.05. The ICC for identifying the time of seizure-onset was 0.15 (95% confidence interval (CI, 0.11-0.18 using AR1 and 0.26 (95% CI 0.21-0.30 using AR2.  The EEG interpretations were often consistent with behavioral, neurophysiological, and neuro-radiological findings, with left sided assignments correct in 95.9% (CI 85.7-98.9%, n=4 of cases using AR2, and 91.9% (77.0-97.5% (n=4 of cases using AR1. Conclusions: EEG artifact reduction methods for localizing seizure-onset does not result in high rates of interpretability, reader confidence, and inter-reader agreement. However, the assignments by groups of readers are often congruent with other clinical data. Utilization of the AR2 software method may improve the validity of ictal EEG artifact reduction.

  20. SU-E-I-13: Evaluation of Metal Artifact Reduction (MAR) Software On Computed Tomography (CT) Images

    International Nuclear Information System (INIS)

    Huang, V; Kohli, K

    2015-01-01

    Purpose: A new commercially available metal artifact reduction (MAR) software in computed tomography (CT) imaging was evaluated with phantoms in the presence of metals. The goal was to assess the ability of the software to restore the CT number in the vicinity of the metals without impacting the image quality. Methods: A Catphan 504 was scanned with a GE Optima RT 580 CT scanner (GE Healthcare, Milwaukee, WI) and the images were reconstructed with and without the MAR software. Both datasets were analyzed with Image Owl QA software (Image Owl Inc, Greenwich, NY). CT number sensitometry, MTF, low contrast, uniformity, noise and spatial accuracy were compared for scans with and without MAR software. In addition, an in-house made phantom was scanned with and without a stainless steel insert at three different locations. The accuracy of the CT number and metal insert dimension were investigated as well. Results: Comparisons between scans with and without MAR algorithm on the Catphan phantom demonstrate similar results for image quality. However, noise was slightly higher for the MAR algorithm. Evaluation of the CT number at various locations of the in-house made phantom was also performed. The baseline HU, obtained from the scan without metal insert, was compared to scans with the stainless steel insert at 3 different locations. The HU difference between the baseline scan versus metal scan was improved when the MAR algorithm was applied. In addition, the physical diameter of the stainless steel rod was over-estimated by the MAR algorithm by 0.9 mm. Conclusion: This work indicates with the presence of metal in CT scans, the MAR algorithm is capable of providing a more accurate CT number without compromising the overall image quality. Future work will include the dosimetric impact on the MAR algorithm

  1. Effectiveness and efficiency of training in digital healthcare packages: training doctors to use digital medical record keeping software.

    Science.gov (United States)

    Benwell, Nicola; Hird, Kathryn; Thomas, Nicholas; Furness, Erin; Fear, Mark; Sweetman, Greg

    2017-10-01

    Objective Fiona Stanley Hospital (FSH) is the first hospital in Western Australia to implement a digital medical record (BOSSnet, Core Medical Solutions, Australia). Formal training in the use of the digital medical record is provided to all staff as part of the induction program. The aim of the present study was to evaluate whether the current training program facilitates efficient and accurate use of the digital medical record in clinical practice. Methods Participants were selected from the cohort of junior doctors employed at FSH in 2015. An e-Learning package of clinically relevant tasks from the digital medical record was created and, along with a questionnaire, completed by participants on two separate occasions. The time taken to complete all tasks and the number of incorrect mouse clicks used to complete each task were recorded and used as measures of efficiency and accuracy respectively. Results Most participants used BOSSnet more than 10 times per day in their clinical roles and self-rated their baseline overall computer proficiency level as high. There was a significant increase in the self-rating of proficiency levels in successive tests. In addition, a significant improvement in both efficiency and accuracy for all participants was measured between the two tests. Interestingly, both groups ended up with similar accuracy on the second trial, despite the second group of participants starting with significantly poorer accuracy. Conclusions Overall, the greatest improvements in task performance followed daily ward-based experience using BOSSnet rather than formalised training. The greatest benefits of training were noted when training was delivered in close proximity to the onset of employment. What is known about the topic? Formalised training in the use of information and communications technology (ICT) is widespread in the health service. However, there is limited evidence to support the modes of learning typically used. Formalised training is often

  2. EQPT, a data file preprocessor for the EQ3/6 software package: User's guide and related documentation (Version 7.0)

    International Nuclear Information System (INIS)

    Daveler, S.A.; Wolery, T.J.

    1992-01-01

    EQPT is a data file preprocessor for the EQ3/6 software package. EQ3/6 currently contains five primary data files, called datao files. These files comprise alternative data sets. These data files contain both standard state and activity coefficient-related data. Three (com, sup, and nea) support the use of the Davies or B equations for the activity coefficients; the other two (hmw and pit) support the use of Pitzer's (1973, 1975) equations. The temperature range of the thermodynamic data on these data files varies from 25 degrees C only to 0-300 degrees C. The principal modeling codes in EQ3/6, EQ3NR and EQ6, do not read a data0 file, however. Instead, these codes read an unformatted equivalent called a data1 file. EQPT writes a datal file, using the corresponding data0 file as input. In processing a data0 file, EQPT checks the data for common errors, such as unbalanced reactions. It also conducts two kinds of data transformation. Interpolating polynomials are fit to data which are input on temperature adds. The coefficients of these polynomials are then written on the datal file in place of the original temperature grids. A second transformation pertains only to data files tied to Pitzer's equations. The commonly reported observable Pitzer coefficient parameters are mapped into a set of primitive parameters by means of a set of conventional relations. These primitive form parameters are then written onto the datal file in place of their observable counterparts. Usage of the primitive form parameters makes it easier to evaluate Pitzer's equations in EQ3NR and EQ6. EQPT and the other codes in the EQ3/6 package are written in FORTRAN 77 and have been developed to run under the UNIX operating system on computers ranging from workstations to supercomputers

  3. EQPT, a data file preprocessor for the EQ3/6 software package: User`s guide and related documentation (Version 7.0); Part 2

    Energy Technology Data Exchange (ETDEWEB)

    Daveler, S.A.; Wolery, T.J.

    1992-12-17

    EQPT is a data file preprocessor for the EQ3/6 software package. EQ3/6 currently contains five primary data files, called datao files. These files comprise alternative data sets. These data files contain both standard state and activity coefficient-related data. Three (com, sup, and nea) support the use of the Davies or B-dot equations for the activity coefficients; the other two (hmw and pit) support the use of Pitzer`s (1973, 1975) equations. The temperature range of the thermodynamic data on these data files varies from 25{degrees}C only to 0-300{degrees}C. The principal modeling codes in EQ3/6, EQ3NR and EQ6, do not read a data0 file, however. Instead, these codes read an unformatted equivalent called a data1 file. EQPT writes a datal file, using the corresponding data0 file as input. In processing a data0 file, EQPT checks the data for common errors, such as unbalanced reactions. It also conducts two kinds of data transformation. Interpolating polynomials are fit to data which are input on temperature adds. The coefficients of these polynomials are then written on the datal file in place of the original temperature grids. A second transformation pertains only to data files tied to Pitzer`s equations. The commonly reported observable Pitzer coefficient parameters are mapped into a set of primitive parameters by means of a set of conventional relations. These primitive form parameters are then written onto the datal file in place of their observable counterparts. Usage of the primitive form parameters makes it easier to evaluate Pitzer`s equations in EQ3NR and EQ6. EQPT and the other codes in the EQ3/6 package are written in FORTRAN 77 and have been developed to run under the UNIX operating system on computers ranging from workstations to supercomputers.

  4. REVERSE LOGISTICS OF PACKAGING AS A SUSTAINABLE STRATEGY FOR COST REDUCTION: A STUDY IN A BOTTLER BEVERAGES

    Directory of Open Access Journals (Sweden)

    Laryssa Guedes de Oliveira

    2013-09-01

    Full Text Available This paper aims to examine the possibility of reducing production costs with the implementation of a program of reverse logistics packaging. Therefore we conducted a literature review focusing on reverse logistics, sustainability, packaging and glass recycling. The research was conducted through a descriptive case study, conducted from a survey and a semi structured interview. The study was developed in a beverage bottler, the Engarrafamento Coroa, a company that adopts in its bottling system using bottles purchased from recycling cooperatives. The results indicate that by reverse logistics is possible to reduce costs and environmental impact associated with the pollution and waste of materials, and provides revenue generation.

  5. TF-finder: A software package for identifying transcription factors involved in biological processes using microarray data and existing knowledge base

    Directory of Open Access Journals (Sweden)

    Cui Xiaoqi

    2010-08-01

    Full Text Available Abstract Background Identification of transcription factors (TFs involved in a biological process is the first step towards a better understanding of the underlying regulatory mechanisms. However, due to the involvement of a large number of genes and complicated interactions in a gene regulatory network (GRN, identification of the TFs involved in a biology process remains to be very challenging. In reality, the recognition of TFs for a given a biological process can be further complicated by the fact that most eukaryotic genomes encode thousands of TFs, which are organized in gene families of various sizes and in many cases with poor sequence conservation except for small conserved domains. This poses a significant challenge for identification of the exact TFs involved or ranking the importance of a set of TFs to a process of interest. Therefore, new methods for recognizing novel TFs are desperately needed. Although a plethora of methods have been developed to infer regulatory genes using microarray data, it is still rare to find the methods that use existing knowledge base in particular the validated genes known to be involved in a process to bait/guide discovery of novel TFs. Such methods can replace the sometimes-arbitrary process of selection of candidate genes for experimental validation and significantly advance our knowledge and understanding of the regulation of a process. Results We developed an automated software package called TF-finder for recognizing TFs involved in a biological process using microarray data and existing knowledge base. TF-finder contains two components, adaptive sparse canonical correlation analysis (ASCCA and enrichment test, for TF recognition. ASCCA uses positive target genes to bait TFS from gene expression data while enrichment test examines the presence of positive TFs in the outcomes from ASCCA. Using microarray data from salt and water stress experiments, we showed TF-finder is very efficient in recognizing

  6. OPTIMIZATION METHOD AND SOFTWARE FOR FUEL COST REDUCTION IN CASE OF ROAD TRANSPORT ACTIVITY

    Directory of Open Access Journals (Sweden)

    György Kovács

    2017-06-01

    Full Text Available The transport activity is one of the most expensive processes in the supply chain and the fuel cost is the highest cost among the cost components of transportation. The goal of the research is to optimize the transport costs in case of a given transport task both by the selecting the optimal petrol station and by determining the optimal amount of the refilled fuel. Recently, in practice, these two decisions have not been made centrally at the forwarding company, but they depend on the individual decision of the driver. The aim of this study is to elaborate a precise and reliable mathematical method for selecting the optimal refuelling stations and determining the optimal amount of the refilled fuel to fulfil the transport demands. Based on the elaborated model, new decision-supporting software is developed for the economical fulfilment of transport trips.

  7. FDSTools: A software package for analysis of massively parallel sequencing data with the ability to recognise and correct STR stutter and other PCR or sequencing noise.

    Science.gov (United States)

    Hoogenboom, Jerry; van der Gaag, Kristiaan J; de Leeuw, Rick H; Sijen, Titia; de Knijff, Peter; Laros, Jeroen F J

    2017-03-01

    Massively parallel sequencing (MPS) is on the advent of a broad scale application in forensic research and casework. The improved capabilities to analyse evidentiary traces representing unbalanced mixtures is often mentioned as one of the major advantages of this technique. However, most of the available software packages that analyse forensic short tandem repeat (STR) sequencing data are not well suited for high throughput analysis of such mixed traces. The largest challenge is the presence of stutter artefacts in STR amplifications, which are not readily discerned from minor contributions. FDSTools is an open-source software solution developed for this purpose. The level of stutter formation is influenced by various aspects of the sequence, such as the length of the longest uninterrupted stretch occurring in an STR. When MPS is used, STRs are evaluated as sequence variants that each have particular stutter characteristics which can be precisely determined. FDSTools uses a database of reference samples to determine stutter and other systemic PCR or sequencing artefacts for each individual allele. In addition, stutter models are created for each repeating element in order to predict stutter artefacts for alleles that are not included in the reference set. This information is subsequently used to recognise and compensate for the noise in a sequence profile. The result is a better representation of the true composition of a sample. Using Promega Powerseq™ Auto System data from 450 reference samples and 31 two-person mixtures, we show that the FDSTools correction module decreases stutter ratios above 20% to below 3%. Consequently, much lower levels of contributions in the mixed traces are detected. FDSTools contains modules to visualise the data in an interactive format allowing users to filter data with their own preferred thresholds. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  8. Summary Describing Integration of ERM Methodology into Supervisory Control Framework with Software Package Documentation; Advanced Reactor Technology Milestone: M4AT-16PN2301052

    Energy Technology Data Exchange (ETDEWEB)

    Ramuhalli, Pradeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hirt, Evelyn H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dib, Gerges [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Veeramany, Arun [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bonebrake, Christopher A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Roy, Surajit [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-20

    This project involved the development of enhanced risk monitors (ERMs) for active components in Advanced Reactor (AdvRx) designs by integrating real-time information about equipment condition with risk monitors. Health monitoring techniques in combination with predictive estimates of component failure based on condition and risk monitors can serve to indicate the risk posed by continued operation in the presence of detected degradation. This combination of predictive health monitoring based on equipment condition assessment and risk monitors can also enable optimization of maintenance scheduling with respect to the economics of plant operation. This report summarizes PNNL’s multi-year project on the development and evaluation of an ERM concept for active components while highlighting FY2016 accomplishments. Specifically, this report provides a status summary of the integration and demonstration of the prototypic ERM framework with the plant supervisory control algorithms being developed at Oak Ridge National Laboratory (ORNL), and describes additional case studies conducted to assess sensitivity of the technology to different quantities. Supporting documentation on the software package to be provided to ONRL is incorporated in this report.

  9. Software package developments around TAPS multidetector: on-line management of GANIL data; mesons neutral identification with the help of neural networks

    International Nuclear Information System (INIS)

    Lefevre, F.

    1993-02-01

    The photon multidetector system TAPS, a European collaboration, was installed for the second series of experiments at GANIL in the fall of 1992. It was used in conjunction with a multidetector for charged particles and the high resolution spectrometer SPEG. This experimental set-up is described. A dedicated software package, written in the PAW environment, for the online control and analysis of data has been developed and is described in detail. One aspect of the TAPS experimental program involves the detection of neutral mesons via two-photon decay. The identification by this decay channel is not trivial due to the so-called combinatorial background-the generation of photon pairs not associated with a meson decay. A method based on a neural network has been developed in order to aid in the extraction of the meson signal. The method is based on that of Hopfield and has been modified to incorporate the self-connection of cells. Our network is thus well suited to solve optimization problems where the initial state of the system represents the data constituting the problem. The performance of the network is presented using simulations and it is demonstrated that the signal-to-noise ratio can be improved given constraints on the solid angle of the detector and the correct identification of the photons

  10. FLIMX: A Software Package to Determine and Analyze the Fluorescence Lifetime in Time-Resolved Fluorescence Data from the Human Eye.

    Directory of Open Access Journals (Sweden)

    Matthias Klemm

    Full Text Available Fluorescence lifetime imaging ophthalmoscopy (FLIO is a new technique for measuring the in vivo autofluorescence intensity decays generated by endogenous fluorophores in the ocular fundus. Here, we present a software package called FLIM eXplorer (FLIMX for analyzing FLIO data. Specifically, we introduce a new adaptive binning approach as an optimal tradeoff between the spatial resolution and the number of photons required per pixel. We also expand existing decay models (multi-exponential, stretched exponential, spectral global analysis, incomplete decay to account for the layered structure of the eye and present a method to correct for the influence of the crystalline lens fluorescence on the retina fluorescence. Subsequently, the Holm-Bonferroni method is applied to FLIO measurements to allow for group comparisons between patients and controls on the basis of fluorescence lifetime parameters. The performance of the new approaches was evaluated in five experiments. Specifically, we evaluated static and adaptive binning in a diabetes mellitus patient, we compared the different decay models in a healthy volunteer and performed a group comparison between diabetes patients and controls. An overview of the visualization capabilities and a comparison of static and adaptive binning is shown for a patient with macular hole. FLIMX's applicability to fluorescence lifetime imaging microscopy is shown in the ganglion cell layer of a porcine retina sample, obtained by a laser scanning microscope using two-photon excitation.

  11. FLIMX: A Software Package to Determine and Analyze the Fluorescence Lifetime in Time-Resolved Fluorescence Data from the Human Eye.

    Science.gov (United States)

    Klemm, Matthias; Schweitzer, Dietrich; Peters, Sven; Sauer, Lydia; Hammer, Martin; Haueisen, Jens

    2015-01-01

    Fluorescence lifetime imaging ophthalmoscopy (FLIO) is a new technique for measuring the in vivo autofluorescence intensity decays generated by endogenous fluorophores in the ocular fundus. Here, we present a software package called FLIM eXplorer (FLIMX) for analyzing FLIO data. Specifically, we introduce a new adaptive binning approach as an optimal tradeoff between the spatial resolution and the number of photons required per pixel. We also expand existing decay models (multi-exponential, stretched exponential, spectral global analysis, incomplete decay) to account for the layered structure of the eye and present a method to correct for the influence of the crystalline lens fluorescence on the retina fluorescence. Subsequently, the Holm-Bonferroni method is applied to FLIO measurements to allow for group comparisons between patients and controls on the basis of fluorescence lifetime parameters. The performance of the new approaches was evaluated in five experiments. Specifically, we evaluated static and adaptive binning in a diabetes mellitus patient, we compared the different decay models in a healthy volunteer and performed a group comparison between diabetes patients and controls. An overview of the visualization capabilities and a comparison of static and adaptive binning is shown for a patient with macular hole. FLIMX's applicability to fluorescence lifetime imaging microscopy is shown in the ganglion cell layer of a porcine retina sample, obtained by a laser scanning microscope using two-photon excitation.

  12. Using of UKRVO Data and Software for New Reductions of Photographic Observations of Selected Minor Planets

    Science.gov (United States)

    Protsyuk, Yu.; Maigurova, N.; Protsyuk, S.; Golovnia, V.

    The new reductions of available photographic plates of UkrVO digital archive containing images of selected minor planets were conducted. Data processing of these plates were carried out to check the possibility of obtaining the new positions with high accuracy in the system of Tycho2/UCAC4 reference catalogues. Archives of the Research Institute "Nikolaev Astronomical Observatory" (NAO) and Main Astronomical Observatory of National Academy of Science (MAO) were used. We have chosen near 60 plates from these archives. Observational epochs of the plates were in the range from 1974 to 1991. Usually, there were 3 exposures in each plate and each plate was scanned 6 times with 1600 dpi resolution. The full identification was conducted and coordinates of all objects were obtained with usage of different options of astrometric reductions. The inner accuracy of obtained positions is within of 0.03"-0.40". The comparison of the new topocentric positions of minor planets with Horizons ephemeris was made for calculation (O - C) residuals and their RMS. The matching with MPC data is present.

  13. Periprosthetic Artifact Reduction Using Virtual Monochromatic Imaging Derived From Gemstone Dual-Energy Computed Tomography and Dedicated Software.

    Science.gov (United States)

    Reynoso, Exequiel; Capunay, Carlos; Rasumoff, Alejandro; Vallejos, Javier; Carpio, Jimena; Lago, Karen; Carrascosa, Patricia

    2016-01-01

    The aim of this study was to explore the usefulness of combined virtual monochromatic imaging and metal artifact reduction software (MARS) for the evaluation of musculoskeletal periprosthetic tissue. Measurements were performed in periprosthetic and remote regions in 80 patients using a high-definition scanner. Polychromatic images with and without MARS and virtual monochromatic images were obtained. Periprosthetic polychromatic imaging (PI) showed significant differences compared with remote areas among the 3 tissues explored (P remote tissues using monochromatic imaging with MARS (P = 0.053 bone, P = 0.32 soft tissue, and P = 0.13 fat). However, such differences were significant using PI with MARS among bone (P = 0.005) and fat (P = 0.02) tissues. All periprosthetic areas were noninterpretable using PI, compared with 11 (9%) using monochromatic imaging. The combined use of virtual monochromatic imaging and MARS reduced periprosthetic artifacts, achieving attenuation levels comparable to implant-free tissue.

  14. Spectral CT with metal artifacts reduction software for improvement of tumor visibility in the vicinity of gold fiducial markers.

    Science.gov (United States)

    Brook, Olga R; Gourtsoyianni, Sofia; Brook, Alexander; Mahadevan, Anand; Wilcox, Carol; Raptopoulos, Vassilios

    2012-06-01

    To evaluate spectral computed tomography (CT) with metal artifacts reduction software (MARS) for reduction of metal artifacts associated with gold fiducial seeds. Thirteen consecutive patients with 37 fiducial seeds implanted for radiation therapy of abdominal lesions were included in this HIPAA-compliant, institutional review board-approved prospective study. Six patients were women (46%) and seven were men (54%). The mean age was 61.1 years (median, 58 years; range, 29-78 years). Spectral imaging was used for arterial phase CT. Images were reconstructed with and without MARS in axial, coronal, and sagittal planes. Two radiologists independently reviewed reconstructions and selected the best image, graded the visibility of the tumor, and assessed the amount of artifacts in all planes. A linear-weighted κ statistic and Wilcoxon signed-rank test were used to assess interobserver variability. Histogram analysis with the Kolmogorov-Smirnov test was used for objective evaluation of artifacts reduction. Fiducial seeds were placed in pancreas (n = 5), liver (n = 7), periportal lymph nodes (n = 1), and gallbladder bed (n = 1). MARS-reconstructed images received a better grade than those with standard reconstruction in 60% and 65% of patients by the first and second radiologist, respectively. Tumor visibility was graded higher with standard versus MARS reconstruction (grade, 3.7 ± 1.0 vs 2.8 ± 1.1; P = .001). Reduction of blooming was noted on MARS-reconstructed images (P = .01). Amount of artifacts, for both any and near field, was significantly smaller on sagittal and coronal MARS-reconstructed images than on standard reconstructions (P MARS-reconstructed images than on standard reconstructions (P MARS than with standard reconstruction in 35 of 37 patients (P MARS improved tumor visibility in the vicinity of gold fiducial seeds.

  15. Nonparametric Statistics Test Software Package.

    Science.gov (United States)

    1983-09-01

    25 I1l,lCELL WRITE (NCF,12 ) IvE (I ,RCCT(I) 122 FORMAT(IlXt 3(H5 9 1) IF( IeLT *NCELL) WRITE (NOF1123 J PARTV(I1J 123 FORMAT( Xll----’,FIo.3J 25 CONT...the user’s entries. Its purpose is to write two types of files needed by the program Crunch: the data file, and the option file. 211 Iuill rateLchiavar...data file and communicate the choice of test and test parameters to Crunch. After a data file is written, Lochinvar prompts the writing of the

  16. Feature selection toolbox software package

    Czech Academy of Sciences Publication Activity Database

    Pudil, Pavel; Novovičová, Jana; Somol, Petr

    2002-01-01

    Roč. 23, č. 4 (2002), s. 487-492 ISSN 0167-8655 R&D Projects: GA ČR GA402/01/0981 Institutional research plan: CEZ:AV0Z1075907 Keywords : pattern recognition * feature selection * loating search algorithms Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.409, year: 2002

  17. Spectral CT with monochromatic imaging and metal artifacts reduction software for artifacts reduction of ¹²⁵I radioactive seeds in liver brachytherapy.

    Science.gov (United States)

    Yang, Qiuxia; Peng, Sheng; Wu, Jing; Ban, Xiaohua; He, Mingyan; Xie, Chuanmiao; Zhang, Rong

    2015-11-01

    To investigate the optimal monochromatic energy for artifacts reduction from (125)I seeds as well as image improvement in the vicinity of seeds on monochromatic images with and without metal artifacts reduction software (MARS) and to compare this with traditional 120-kVp images, so as to evaluate the application value of gemstone spectral imaging for reducing artifacts from (125)I seeds in liver brachytherapy. A total of 45 tumors from 25 patients treated with (125)I seed brachytherapy in the liver were enrolled in this study. Multiphasic spectral computed tomography (CT) scanning was performed for each patient. After a delay time of 15 s of portal vein phase, a traditional 120-kVp scan was performed, focusing on several planes of (125)I seeds only. The artifact index (AI) in the vicinity of seeds and the standard deviation (SD) of the CT density of region of interest in the outside liver parenchyma were calculated. Artifact appearance was evaluated and classified on reconstructed monochromatic S and 120-kVp images. Image quality in the vicinity of seeds of three data sets were evaluated using a 1-5 scale scoring method. The Friedman rank-sum test was used to estimate the scoring results of image quality. The greatest noise in monochromatic images was found at 40 keV (SD = 27.38, AI = 206.40). The optimal monochromatic energy was found at 75 keV, which provided almost the least image noise (SD = 10.01) and good performance in artifact reduction (AI = 102.73). Image noise and AI reduction at 75 keV was decreased by 63.44 and 50.23%, compared with at 40 keV. Near-field thick artifacts were obvious in all 45 lesions, in 120-kVp images, and 75-keV images, but basically reduced in 75 keV MARS images and artifacts completely invisible in 7 lesions. The number of diagnosable images (score ≥3) was significantly more in the 75-keV MARS group (28/45), and the 75-keV group (22/45) than in the 120-kVp group (11/45) (p improve image quality, even to a state of being

  18. New image-processing and noise-reduction software reduces radiation dose during complex endovascular procedures.

    Science.gov (United States)

    Kirkwood, Melissa L; Guild, Jeffrey B; Arbique, Gary M; Tsai, Shirling; Modrall, J Gregory; Anderson, Jon A; Rectenwald, John; Timaran, Carlos

    2016-11-01

    A new proprietary image-processing system known as AlluraClarity, developed by Philips Healthcare (Best, The Netherlands) for radiation-based interventional procedures, claims to lower radiation dose while preserving image quality using noise-reduction algorithms. This study determined whether the surgeon and patient radiation dose during complex endovascular procedures (CEPs) is decreased after the implementation of this new operating system. Radiation dose to operators, procedure type, reference air kerma, kerma area product, and patient body mass index were recorded during CEPs on two Philips Allura FD 20 fluoroscopy systems with and without Clarity. Operator dose during CEPs was measured using optically stimulable, luminescent nanoDot (Landauer Inc, Glenwood, Ill) detectors placed outside the lead apron at the left upper chest position. nanoDots were read using a microStar ii (Landauer Inc) medical dosimetry system. For the CEPs in the Clarity group, the radiation dose to surgeons was also measured by the DoseAware (Philips Healthcare) personal dosimetry system. Side-by-side measurements of DoseAware and nanoDots allowed for cross-calibration between systems. Operator effective dose was determined using a modified Niklason algorithm. To control for patient size and case complexity, the average fluoroscopy dose rate and the dose per radiographic frame were adjusted for body mass index differences and then compared between the groups with and without Clarity by procedure. Additional factors, for example, physician practice patterns, that may have affected operator dose were inferred by comparing the ratio of the operator dose to procedural kerma area product with and without Clarity. A one-sided Wilcoxon rank sum test was used to compare groups for radiation doses, reference air kermas, and operating practices for each procedure type. The analysis included 234 CEPs; 95 performed without Clarity and 139 with Clarity. Practice patterns of operators during

  19. Procedures to analyse γ-ray spectra obtained from the ORTEC or nuclear data ND-680 system by ORTEC's analysis software packages incorporated into a separate IBM-PC computer

    International Nuclear Information System (INIS)

    Zhang Xiu Zhen.

    1990-01-01

    A detailed description is presented for processing γ-spectra produced by means of Ortec or Nuclear Data spectrometry systems on an off-line IBM-PC. The ORTEC analysis software packages were transferred to and implemented on the PC A/T, and the different spectra were recorded on discs and subsequently brought into the format required by the program for the calculation of photo peak areas. (author)

  20. HYPERDIRE. HYPERgeometric functions DIfferential REduction. MATEMATICA based packages for differential reduction of generalized hypergeometric functions. FD and FS Horn-type hypergeometric functions of three variables

    International Nuclear Information System (INIS)

    Bytev, Vladimir V.; Kalmykov, Mikhail Yu.; Moch, Sven-Olaf; Hamburg Univ.

    2013-12-01

    HYPERDIRE is a project devoted to the creation of a set of Mathematica based programs for the differential reduction of hypergeometric functions. The current version includes two parts: the first one, FdFunction, for manipulations with Appell hypergeometric functions F D of r variables; and the second one, FsFunction, for manipulations with Lauricella-Saran hypergeometric functions F S of three variables. Both functions are related with one-loop Feynman diagrams.

  1. HYPERDIRE. HYPERgeometric functions DIfferential REduction. MATHEMATICA based packages for differential reduction of generalized hypergeometric functions pFp-1, F1, F2, F3, F4

    International Nuclear Information System (INIS)

    Bytev, Vladimir V.; Kalmykov, Mikhail Yu.; Kniehl, Bernd A.

    2013-05-01

    HYPERDIRE is a project devoted to the creation of a set of Mathematica based programs for the differential reduction of hypergeometric functions. The current version includes two parts: one, pfq, is relevant for manipulations of hypergeometric functions p+1 F p , and the second one, AppellF1F4, for manipulations with Appell hypergeometric functions F 1 , F 2 , F 3 , F 4 of two variables.

  2. Reviews, Software.

    Science.gov (United States)

    Science Teacher, 1988

    1988-01-01

    Reviews two computer software packages for use in physical science, physics, and chemistry classes. Includes "Physics of Model Rocketry" for Apple II, and "Black Box" for Apple II and IBM compatible computers. "Black Box" is designed to help students understand the concept of indirect evidence. (CW)

  3. Software Reviews.

    Science.gov (United States)

    Kinnaman, Daniel E.; And Others

    1988-01-01

    Reviews four educational software packages for Apple, IBM, and Tandy computers. Includes "How the West was One + Three x Four,""Mavis Beacon Teaches Typing,""Math and Me," and "Write On." Reviews list hardware requirements, emphasis, levels, publisher, purchase agreements, and price. Discusses the strengths…

  4. Software Review.

    Science.gov (United States)

    McGrath, Diane, Ed.

    1989-01-01

    Reviewed is a computer software package entitled "Audubon Wildlife Adventures: Grizzly Bears" for Apple II and IBM microcomputers. Included are availability, hardware requirements, cost, and a description of the program. The murder-mystery flavor of the program is stressed in this program that focuses on illegal hunting and game…

  5. Software Reviews.

    Science.gov (United States)

    Teles, Elizabeth, Ed.; And Others

    1990-01-01

    Reviewed are two computer software packages for Macintosh microcomputers including "Phase Portraits," an exploratory graphics tool for studying first-order planar systems; and "MacMath," a set of programs for exploring differential equations, linear algebra, and other mathematical topics. Features, ease of use, cost, availability, and hardware…

  6. High-Resolution C-Arm CT and Metal Artifact Reduction Software: A Novel Imaging Modality for Analyzing Aneurysms Treated with Stent-Assisted Coil Embolization.

    Science.gov (United States)

    Yuki, I; Kambayashi, Y; Ikemura, A; Abe, Y; Kan, I; Mohamed, A; Dahmani, C; Suzuki, T; Ishibashi, T; Takao, H; Urashima, M; Murayama, Y

    2016-02-01

    Combination of high-resolution C-arm CT and novel metal artifact reduction software may contribute to the assessment of aneurysms treated with stent-assisted coil embolization. This study aimed to evaluate the efficacy of a novel Metal Artifact Reduction prototype software combined with the currently available high spatial-resolution C-arm CT prototype implementation by using an experimental aneurysm model treated with stent-assisted coil embolization. Eight experimental aneurysms were created in 6 swine. Coil embolization of each aneurysm was performed by using a stent-assisted technique. High-resolution C-arm CT with intra-arterial contrast injection was performed immediately after the treatment. The obtained images were processed with Metal Artifact Reduction. Five neurointerventional specialists reviewed the image quality before and after Metal Artifact Reduction. Observational and quantitative analyses (via image analysis software) were performed. Every aneurysm was successfully created and treated with stent-assisted coil embolization. Before Metal Artifact Reduction, coil loops protruding through the stent lumen were not visualized due to the prominent metal artifacts produced by the coils. These became visible after Metal Artifact Reduction processing. Contrast filling in the residual aneurysm was also visualized after Metal Artifact Reduction in every aneurysm. Both the observational (P software. The combination of high-resolution C-arm CT and Metal Artifact Reduction enables differentiation of the coil mass, stent, and contrast material on the same image by significantly reducing the metal artifacts produced by the platinum coils. This novel image technique may improve the assessment of aneurysms treated with stent-assisted coil embolization. © 2016 by American Journal of Neuroradiology.

  7. SEL's Software Process-Improvement Program

    Science.gov (United States)

    Basili, Victor; Zelkowitz, Marvin; McGarry, Frank; Page, Jerry; Waligora, Sharon; Pajerski, Rose

    1995-01-01

    The goals and operations of the Software Engineering Laboratory (SEL) is reviewed. For nearly 20 years the SEL has worked to understand, assess, and improve software and the development process within the production environment of the Flight Dynamics Division (FDD) of NASA's Goddard Space Flight Center. The SEL was established in 1976 with the goals of reducing: (1) the defect rate of delivered software, (2) the cost of software to support flight projects, and (3) the average time to produce mission-support software. After studying over 125 projects of FDD, the results have guided the standards, management practices, technologies, and the training within the division. The results of the studies have been a 75 percent reduction in defects, a 50 percent reduction in cost, and a 25 percent reduction in development time. Over time the goals of SEL have been clarified. The goals are now stated as: (1) Understand baseline processes and product characteristics, (2) Assess improvements that have been incorporated into the development projects, (3) Package and infuse improvements into the standard SEL process. The SEL improvement goal is to demonstrate continual improvement of the software process by carrying out analysis, measurement and feedback to projects with in the FDD environment. The SEL supports the understanding of the process by study of several processes including, the effort distribution, and error detection rates. The SEL assesses and refines the processes. Once the assessment and refinement of a process is completed, the SEL packages the process by capturing the process in standards, tools and training.

  8. Packaging fluency

    DEFF Research Database (Denmark)

    Mocanu, Ana; Chrysochou, Polymeros; Bogomolova, Svetlana

    2011-01-01

    Research on packaging stresses the need for packaging design to read easily, presuming fast and accurate processing of product-related information. In this paper we define this property of packaging as “packaging fluency”. Based on the existing marketing and cognitive psychology literature on pac...

  9. UFMulti: A new parallel processing software system for HEP

    Science.gov (United States)

    Avery, Paul; White, Andrew

    1989-12-01

    UFMulti is a multiprocessing software package designed for general purpose high energy physics applications, including physics and detector simulation, data reduction and DST physics analysis. The system is particularly well suited for installations where several workstation or computers are connected through a local area network (LAN). The initial configuration of the software is currently running on VAX/VMS machines with a planned extension to ULTRIX, using the new RISC CPUs from Digital, in the near future.

  10. UFMULTI: A new parallel processing software system for HEP

    International Nuclear Information System (INIS)

    Avery, P.; White, A.

    1989-01-01

    UFMulti is a multiprocessing software package designed for general purpose high energy physics applications, including physics and detector simulation, data reduction and DST physics analysis. The system is particularly well suited for installations where several workstations or computers are connected through a local area network (LAN). The initial configuration of the software is currently running on VAX/VMS machines with a planned extension to ULTRIX, using the new RISC CPUs from Digital, in the near future. (orig.)

  11. Microelectronic packaging

    CERN Document Server

    Datta, M; Schultze, J Walter

    2004-01-01

    Microelectronic Packaging analyzes the massive impact of electrochemical technologies on various levels of microelectronic packaging. Traditionally, interconnections within a chip were considered outside the realm of packaging technologies, but this book emphasizes the importance of chip wiring as a key aspect of microelectronic packaging, and focuses on electrochemical processing as an enabler of advanced chip metallization.Divided into five parts, the book begins by outlining the basics of electrochemical processing, defining the microelectronic packaging hierarchy, and emphasizing the impac

  12. Does HDR Pre-Processing Improve the Accuracy of 3D Models Obtained by Means of two Conventional SfM-MVS Software Packages? The Case of the Corral del Veleta Rock Glacier

    Directory of Open Access Journals (Sweden)

    Álvaro Gómez-Gutiérrez

    2015-08-01

    Full Text Available The accuracy of different workflows using Structure-from-Motion and Multi-View-Stereo techniques (SfM-MVS is tested. Twelve point clouds of the Corral del Veleta rock glacier, in Spain, were produced with two different software packages (123D Catch and Agisoft Photoscan, using Low Dynamic Range images and High Dynamic Range compositions (HDR for three different years (2011, 2012 and 2014. The accuracy of the resulting point clouds was assessed using benchmark models acquired every year with a Terrestrial Laser Scanner. Three parameters were used to estimate the accuracy of each point cloud: the RMSE, the Cloud-to-Cloud distance (C2C and the Multiscale-Model-to-Model comparison (M3C2. The M3C2 mean error ranged from 0.084 m (standard deviation of 0.403 m to 1.451 m (standard deviation of 1.625 m. Agisoft Photoscan overcome 123D Catch, producing more accurate and denser point clouds in 11 out 12 cases, being this work, the first available comparison between both software packages in the literature. No significant improvement was observed using HDR pre-processing. To our knowledge, this is the first time that the geometrical accuracy of 3D models obtained using LDR and HDR compositions are compared. These findings may be of interest for researchers who wish to estimate geomorphic changes using SfM-MVS approaches.

  13. g-PRIME: A Free, Windows Based Data Acquisition and Event Analysis Software Package for Physiology in Classrooms and Research Labs.

    Science.gov (United States)

    Lott, Gus K; Johnson, Bruce R; Bonow, Robert H; Land, Bruce R; Hoy, Ronald R

    2009-01-01

    We present g-PRIME, a software based tool for physiology data acquisition, analysis, and stimulus generation in education and research. This software was developed in an undergraduate neurophysiology course and strongly influenced by instructor and student feedback. g-PRIME is a free, stand-alone, windows application coded and "compiled" in Matlab (does not require a Matlab license). g-PRIME supports many data acquisition interfaces from the PC sound card to expensive high throughput calibrated equipment. The program is designed as a software oscilloscope with standard trigger modes, multi-channel visualization controls, and data logging features. Extensive analysis options allow real time and offline filtering of signals, multi-parameter threshold-and-window based event detection, and two-dimensional display of a variety of parameters including event time, energy density, maximum FFT frequency component, max/min amplitudes, and inter-event rate and intervals. The software also correlates detected events with another simultaneously acquired source (event triggered average) in real time or offline. g-PRIME supports parameter histogram production and a variety of elegant publication quality graphics outputs. A major goal of this software is to merge powerful engineering acquisition and analysis tools with a biological approach to studies of nervous system function.

  14. MEMS packaging

    CERN Document Server

    Hsu , Tai-Ran

    2004-01-01

    MEMS Packaging discusses the prevalent practices and enabling techniques in assembly, packaging and testing of microelectromechanical systems (MEMS). The entire spectrum of assembly, packaging and testing of MEMS and microsystems, from essential enabling technologies to applications in key industries of life sciences, telecommunications and aerospace engineering is covered. Other topics included are bonding and sealing of microcomponents, process flow of MEMS and microsystems packaging, automated microassembly, and testing and design for testing.The Institution of Engineering and Technology is

  15. Computer Center: Software Review.

    Science.gov (United States)

    Duhrkopf, Richard, Ed.; Belshe, John F., Ed.

    1988-01-01

    Reviews a software package, "Mitosis-Meiosis," available for Apple II or IBM computers with colorgraphics capabilities. Describes the documentation, presentation and flexibility of the program. Rates the program based on graphics and usability in a biology classroom. (CW)

  16. Gammasphere software development

    International Nuclear Information System (INIS)

    Piercey, R.B.

    1994-01-01

    This report describes the activities of the nuclear physics group at Mississippi State University which were performed during 1993. Significant progress has been made in the focus areas: chairing the Gammasphere Software Working Group (SWG); assisting with the porting and enhancement of the ORNL UPAK histogramming software package; and developing standard formats for Gammasphere data products. In addition, they have established a new public ftp archive to distribute software and software development tools and information

  17. ROLE OF DATA MINING CLASSIFICATION TECHNIQUE IN SOFTWARE DEFECT PREDICTION

    OpenAIRE

    Dr.A.R.Pon Periyasamy; Mrs A.Misbahulhuda

    2017-01-01

    Software defect prediction is the process of locating defective modules in software. Software quality may be a field of study and apply that describes the fascinating attributes of software package product. The performance should be excellent with none defects. Software quality metrics are a set of software package metrics that target the standard aspects of the product, process, and project. The software package defect prediction model helps in early detection of defects and contributes to t...

  18. The fundamentals behind solving for unknown molecular structures using computer-assisted structure elucidation: a free software package at the undergraduate and graduate levels.

    Science.gov (United States)

    Moser, Arvin; Pautler, Brent G

    2016-05-15

    The successful elucidation of an unknown compound's molecular structure often requires an analyst with profound knowledge and experience of advanced spectroscopic techniques, such as Nuclear Magnetic Resonance (NMR) spectroscopy and mass spectrometry. The implementation of Computer-Assisted Structure Elucidation (CASE) software in solving for unknown structures, such as isolated natural products and/or reaction impurities, can serve both as elucidation and teaching tools. As such, the introduction of CASE software with 112 exercises to train students in conjunction with the traditional pen and paper approach will strengthen their overall understanding of solving unknowns and explore of various structural end points to determine the validity of the results quickly. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  19. The software developing method for multichannel computer-aided system for physical experiments control, realized by resources of national instruments LabVIEW instrumental package

    International Nuclear Information System (INIS)

    Gorskaya, E.A.; Samojlov, V.N.

    1999-01-01

    This work is describing the method of developing the computer-aided control system in integrated environment of LabVIEW. Using the object-oriented design of complex systems, the hypothetical model for methods of developing the software for computer-aided system for physical experiments control was constructed. Within the framework of that model architecture solutions and implementations of suggested method were described. (author)

  20. The new 'BerSANS-PC' software for reduction and treatment of small angle neutron scattering data

    International Nuclear Information System (INIS)

    Keiderling, U.

    2002-01-01

    Measurements on small angle neutron scattering (SANS) instruments are typically characterized by a large number of samples, short measurement times for the individual samples, and a frequent change of visiting scientist groups. Besides this, recent advances in instrumentation have led to more frequent measurements of kinetic sequences and a growing interest in analyzing two-dimensional scattering data, these requiring special software tools that enable the users to extract physically relevant information from the scattering data with a minimum of effort. The new 'BerSANS-PC' data-processing software has been developed at the Hahn-Meitner-Institut (HMI) in Berlin, Germany, to meet these requirements and to support an efficiently working guest-user service. Comprising some basic functions of the 'BerSANS' program available at the HMI and other institutes in the past, BerSANS-PC is a completely new development for network-independent use on local PCs with a full-feature graphical interface. (orig.)

  1. Development of standardized approaches to reporting of minimal residual disease data using a reporting software package designed within the European LeukemiaNet

    DEFF Research Database (Denmark)

    Ostergaard, M; Nyvold, Charlotte Guldborg; Jovanovic, J V

    2011-01-01

    Quantitative PCR (qPCR) for detection of fusion transcripts and overexpressed genes is a promising tool for following minimal residual disease (MRD) in patients with hematological malignancies. Its widespread clinical use has to some extent been hampered by differences in data analysis and presen......Quantitative PCR (qPCR) for detection of fusion transcripts and overexpressed genes is a promising tool for following minimal residual disease (MRD) in patients with hematological malignancies. Its widespread clinical use has to some extent been hampered by differences in data analysis...... and presentation that complicate multicenter clinical trials. To address these issues, we designed a highly flexible MRD-reporting software program, in which data from various qPCR platforms can be imported, processed, and presented in a uniform manner to generate intuitively understandable reports. The software...... was tested in a two-step quality control (QC) study; the first step involved eight centers, whose previous experience with the software ranged from none to extensive. The participants received cDNA from consecutive samples from a BCR-ABL+ chronic myeloid leukemia (CML) patient and an acute myeloid leukemia...

  2. cgDNA: a software package for the prediction of sequence-dependent coarse-grain free energies of B-form DNA.

    Science.gov (United States)

    Petkevičiūtė, D; Pasi, M; Gonzalez, O; Maddocks, J H

    2014-11-10

    cgDNA is a package for the prediction of sequence-dependent configuration-space free energies for B-form DNA at the coarse-grain level of rigid bases. For a fragment of any given length and sequence, cgDNA calculates the configuration of the associated free energy minimizer, i.e. the relative positions and orientations of each base, along with a stiffness matrix, which together govern differences in free energies. The model predicts non-local (i.e. beyond base-pair step) sequence dependence of the free energy minimizer. Configurations can be input or output in either the Curves+ definition of the usual helical DNA structural variables, or as a PDB file of coordinates of base atoms. We illustrate the cgDNA package by comparing predictions of free energy minimizers from (a) the cgDNA model, (b) time-averaged atomistic molecular dynamics (or MD) simulations, and (c) NMR or X-ray experimental observation, for (i) the Dickerson-Drew dodecamer and (ii) three oligomers containing A-tracts. The cgDNA predictions are rather close to those of the MD simulations, but many orders of magnitude faster to compute. Both the cgDNA and MD predictions are in reasonable agreement with the available experimental data. Our conclusion is that cgDNA can serve as a highly efficient tool for studying structural variations in B-form DNA over a wide range of sequences. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  3. Software for Managing Personal Files.

    Science.gov (United States)

    Lundeen, Gerald

    1989-01-01

    Discusses the special characteristics of personal file management software and compares four microcomputer software packages: Notebook II with Bibliography and Convert, Pro-Cite with Biblio-Links, askSam, and Reference Manager. Each package is evaluated in terms of the user interface, file maintenance, retrieval capabilities, output, and…

  4. SU-G-IeP3-05: Effects of Image Receptor Technology and Dose Reduction Software On Radiation Dose Estimates for Fluoroscopically-Guided Interventional (FGI) Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Merritt, Z; Dave, J; Eschelman, D; Gonsalves, C [Thomas Jefferson University, Philadelphia, PA (United States)

    2016-06-15

    Purpose: To investigate the effects of image receptor technology and dose reduction software on radiation dose estimates for most frequently performed fluoroscopically-guided interventional (FGI) procedures at a tertiary health care center. Methods: IRB approval was obtained for retrospective analysis of FGI procedures performed in the interventional radiology suites between January-2011 and December-2015. This included procedures performed using image-intensifier (II) based systems which were subsequently replaced, flat-panel-detector (FPD) based systems which were later upgraded with ClarityIQ dose reduction software (Philips Healthcare) and relatively new FPD system already equipped with ClarityIQ. Post procedure, technologists entered system-reported cumulative air kerma (CAK) and kerma-area product (KAP; only KAP for II based systems) in RIS; these values were analyzed. Data pre-processing included correcting typographical errors and cross-verifying CAK and KAP. The most frequent high and low dose FGI procedures were identified and corresponding CAK and KAP values were compared. Results: Out of 27,251 procedures within this time period, most frequent high and low dose procedures were chemo/immuno-embolization (n=1967) and abscess drainage (n=1821). Mean KAP for embolization and abscess drainage procedures were 260,657, 310,304 and 94,908 mGycm{sup 2}, and 14,497, 15,040 and 6307 mGycm{sup 2} using II-, FPD- and FPD with ClarityIQ- based systems, respectively. Statistically significant differences were observed in KAP values for embolization procedures with respect to different systems but for abscess drainage procedures significant differences were only noted between systems with FPD and FPD with ClarityIQ (p<0.05). Mean CAK reduced significantly from 823 to 308 mGy and from 43 to 21 mGy for embolization and abscess drainage procedures, respectively, in transitioning to FPD systems with ClarityIQ (p<0.05). Conclusion: While transitioning from II- to FPD- based

  5. Packaging microservices

    DEFF Research Database (Denmark)

    Montesi, Fabrizio; Thrane, Dan Sebastian

    2017-01-01

    We describe a first proposal for a new packaging system for microservices based on the Jolie programming language, called the Jolie Package Manager (JPM). Its main features revolve around service interfaces, which make the functionalities that a service provides and depends on explicit. For the f......We describe a first proposal for a new packaging system for microservices based on the Jolie programming language, called the Jolie Package Manager (JPM). Its main features revolve around service interfaces, which make the functionalities that a service provides and depends on explicit...

  6. Parallelizing Compiler Framework and API for Power Reduction and Software Productivity of Real-Time Heterogeneous Multicores

    Science.gov (United States)

    Hayashi, Akihiro; Wada, Yasutaka; Watanabe, Takeshi; Sekiguchi, Takeshi; Mase, Masayoshi; Shirako, Jun; Kimura, Keiji; Kasahara, Hironori

    Heterogeneous multicores have been attracting much attention to attain high performance keeping power consumption low in wide spread of areas. However, heterogeneous multicores force programmers very difficult programming. The long application program development period lowers product competitiveness. In order to overcome such a situation, this paper proposes a compilation framework which bridges a gap between programmers and heterogeneous multicores. In particular, this paper describes the compilation framework based on OSCAR compiler. It realizes coarse grain task parallel processing, data transfer using a DMA controller, power reduction control from user programs with DVFS and clock gating on various heterogeneous multicores from different vendors. This paper also evaluates processing performance and the power reduction by the proposed framework on a newly developed 15 core heterogeneous multicore chip named RP-X integrating 8 general purpose processor cores and 3 types of accelerator cores which was developed by Renesas Electronics, Hitachi, Tokyo Institute of Technology and Waseda University. The framework attains speedups up to 32x for an optical flow program with eight general purpose processor cores and four DRP(Dynamically Reconfigurable Processor) accelerator cores against sequential execution by a single processor core and 80% of power reduction for the real-time AAC encoding.

  7. Selection of software for mechanical engineering undergraduates

    International Nuclear Information System (INIS)

    Cheah, C. T.; Yin, C. S.; Halim, T.; Naser, J.; Blicblau, A. S.

    2016-01-01

    A major problem with the undergraduate mechanical course is the limited exposure of students to software packages coupled with the long learning curve on the existing software packages. This work proposes the use of appropriate software packages for the entire mechanical engineering curriculum to ensure students get sufficient exposure real life design problems. A variety of software packages are highlighted as being suitable for undergraduate work in mechanical engineering, e.g. simultaneous non-linear equations; uncertainty analysis; 3-D modeling software with the FEA; analysis tools for the solution of problems in thermodynamics, fluid mechanics, mechanical system design, and solid mechanics.

  8. Selection of software for mechanical engineering undergraduates

    Energy Technology Data Exchange (ETDEWEB)

    Cheah, C. T.; Yin, C. S.; Halim, T.; Naser, J.; Blicblau, A. S., E-mail: ablicblau@swin.edu.au [Swinburne University of Technology, Faculty of Science Engineering and Technology, PO Box 218 Hawthorn, Victoria, Australia, 3122 (Australia)

    2016-07-12

    A major problem with the undergraduate mechanical course is the limited exposure of students to software packages coupled with the long learning curve on the existing software packages. This work proposes the use of appropriate software packages for the entire mechanical engineering curriculum to ensure students get sufficient exposure real life design problems. A variety of software packages are highlighted as being suitable for undergraduate work in mechanical engineering, e.g. simultaneous non-linear equations; uncertainty analysis; 3-D modeling software with the FEA; analysis tools for the solution of problems in thermodynamics, fluid mechanics, mechanical system design, and solid mechanics.

  9. A cross-validation package driving Netica with python

    Science.gov (United States)

    Fienen, Michael N.; Plant, Nathaniel G.

    2014-01-01

    Bayesian networks (BNs) are powerful tools for probabilistically simulating natural systems and emulating process models. Cross validation is a technique to avoid overfitting resulting from overly complex BNs. Overfitting reduces predictive skill. Cross-validation for BNs is known but rarely implemented due partly to a lack of software tools designed to work with available BN packages. CVNetica is open-source, written in Python, and extends the Netica software package to perform cross-validation and read, rebuild, and learn BNs from data. Insights gained from cross-validation and implications on prediction versus description are illustrated with: a data-driven oceanographic application; and a model-emulation application. These examples show that overfitting occurs when BNs become more complex than allowed by supporting data and overfitting incurs computational costs as well as causing a reduction in prediction skill. CVNetica evaluates overfitting using several complexity metrics (we used level of discretization) and its impact on performance metrics (we used skill).

  10. Software for microcircuit systems

    International Nuclear Information System (INIS)

    Kunz, P.F.

    1978-10-01

    Modern Large Scale Integration (LSI) microcircuits are meant to be programed in order to control the function that they perform. The basics of microprograming and new microcircuits have already been discussed. In this course, the methods of developing software for these microcircuits are explored. This generally requires a package of support software in order to assemble the microprogram, and also some amount of support software to test the microprograms and to test the microprogramed circuit itself. 15 figures, 2 tables

  11. An approach to the analysis of SDSS spectroscopic outliers based on self-organizing maps. Designing the outlier analysis software package for the next Gaia survey

    Science.gov (United States)

    Fustes, D.; Manteiga, M.; Dafonte, C.; Arcay, B.; Ulla, A.; Smith, K.; Borrachero, R.; Sordo, R.

    2013-11-01

    Aims: A new method applied to the segmentation and further analysis of the outliers resulting from the classification of astronomical objects in large databases is discussed. The method is being used in the framework of the Gaia satellite Data Processing and Analysis Consortium (DPAC) activities to prepare automated software tools that will be used to derive basic astrophysical information that is to be included in final Gaia archive. Methods: Our algorithm has been tested by means of simulated Gaia spectrophotometry, which is based on SDSS observations and theoretical spectral libraries covering a wide sample of astronomical objects. Self-organizing maps networks are used to organize the information in clusters of objects, as homogeneously as possible according to their spectral energy distributions, and to project them onto a 2D grid where the data structure can be visualized. Results: We demonstrate the usefulness of the method by analyzing the spectra that were rejected by the SDSS spectroscopic classification pipeline and thus classified as "UNKNOWN". First, our method can help distinguish between astrophysical objects and instrumental artifacts. Additionally, the application of our algorithm to SDSS objects of unknown nature has allowed us to identify classes of objects with similar astrophysical natures. In addition, the method allows for the potential discovery of hundreds of new objects, such as white dwarfs and quasars. Therefore, the proposed method is shown to be very promising for data exploration and knowledge discovery in very large astronomical databases, such as the archive from the upcoming Gaia mission.

  12. The Use of Utility Accounting Software at Miami University.

    Science.gov (United States)

    Wenner, Paul

    1999-01-01

    Describes how Miami University successfully developed an accounting software package that tracked and recorded their utility usage, including examples of its graphics and reporting components. Background information examining the decision to pursue an energy management software package is included. (GR)

  13. Development of a Nevada Statewide Database for Safety Analyst Software

    Science.gov (United States)

    2017-02-02

    Safety Analyst is a software package developed by the Federal Highway Administration (FHWA) and twenty-seven participating state and local agencies including the Nevada Department of Transportation (NDOT). The software package implemented many of the...

  14. Calculation Software versus Illustration Software for Teaching Statistics

    DEFF Research Database (Denmark)

    Mortensen, Peter Stendahl; Boyle, Robin G.

    1999-01-01

    As personal computers have become more and more powerful, so have the software packages available to us for teaching statistics. This paper investigates what software packages are currently being used by progressive statistics instructors at university level, examines some of the deficiencies...... of such software, and indicates features that statistics instructors wish to have incorporated in software in the future. The basis of the paper is a survey of participants at ICOTS-5 (the Fifth International Conference on Teaching Statistics). These survey results, combined with the software based papers...

  15. Comparative Packaging Study

    Science.gov (United States)

    Perchonok, Michele H.; Oziomek, Thomas V.

    2009-01-01

    Future long duration manned space flights beyond low earth orbit will require the food system to remain safe, acceptable and nutritious. Development of high barrier food packaging will enable this requirement by preventing the ingress and egress of gases and moisture. New high barrier food packaging materials have been identified through a trade study. Practical application of this packaging material within a shelf life test will allow for better determination of whether this material will allow the food system to meet given requirements after the package has undergone processing. The reason to conduct shelf life testing, using a variety of packaging materials, stems from the need to preserve food used for mission durations of several years. Chemical reactions that take place during longer durations may decrease food quality to a point where crew physical or psychological well-being is compromised. This can result in a reduction or loss of mission success. The rate of chemical reactions, including oxidative rancidity and staling, can be controlled by limiting the reactants, reducing the amount of energy available to drive the reaction, and minimizing the amount of water available. Water not only acts as a media for microbial growth, but also as a reactant and means by which two reactants may come into contact with each other. The objective of this study is to evaluate three packaging materials for potential use in long duration space exploration missions.

  16. The portability of the "Electronics Workbench" simulation software to China

    NARCIS (Netherlands)

    Collis, Betty; Zhi-Cheng, Dong

    1993-01-01

    This article discusses the portability of the Canadian-made simulation software package, "Electronic Workbench" package (EWB) to China. As part of a larger project investigating the portability of various educational software packages, the EWB package was used in electronics instruction in China and

  17. Effect of metal artifact reduction software on image quality of C-arm cone-beam computed tomography during intracranial aneurysm treatment.

    Science.gov (United States)

    Enomoto, Yukiko; Yamauchi, Keita; Asano, Takahiko; Otani, Katharina; Iwama, Toru

    2018-01-01

    Background and purpose C-arm cone-beam computed tomography (CBCT) has the drawback that image quality is degraded by artifacts caused by implanted metal objects. We evaluated whether metal artifact reduction (MAR) prototype software can improve the subjective image quality of CBCT images of patients with intracranial aneurysms treated with coils or clips. Materials and methods Forty-four patients with intracranial aneurysms implanted with coils (40 patients) or clips (four patients) underwent one CBCT scan from which uncorrected and MAR-corrected CBCT image datasets were reconstructed. Three blinded readers evaluated the image quality of the image sets using a four-point scale (1: Excellent, 2: Good, 3: Poor, 4: Bad). The median scores of the three readers of uncorrected and MAR-corrected images were compared with the paired Wilcoxon signed-rank and inter-reader agreement of change scores was assessed by weighted kappa statistics. The readers also recorded new clinical findings, such as intracranial hemorrhage, air, or surrounding anatomical structures on MAR-corrected images. Results The image quality of MAR-corrected CBCT images was significantly improved compared with the uncorrected CBCT image ( p software improved image quality of CBCT images degraded by metal artifacts.

  18. Metal artifact reduction software used with abdominopelvic dual-energy CT of patients with metal hip prostheses: assessment of image quality and clinical feasibility.

    Science.gov (United States)

    Han, Seung Chol; Chung, Yong Eun; Lee, Young Han; Park, Kwan Kyu; Kim, Myeong Jin; Kim, Ki Whang

    2014-10-01

    The objective of our study was to determine the feasibility of using Metal Artifact Reduction (MAR) software for abdominopelvic dual-energy CT in patients with metal hip prostheses. This retrospective study included 33 patients (male-female ratio, 19:14; mean age, 63.7 years) who received total hip replacements and 20 patients who did not have metal prostheses as the control group. All of the patients underwent dual-energy CT. The quality of the images reconstructed using the MAR algorithm and of those reconstructed using the standard reconstruction was evaluated in terms of the visibility of the bladder wall, pelvic sidewall, rectal shelf, and bone-prosthesis interface and the overall diagnostic image quality with a 4-point scale. The mean and SD attenuation values in Hounsfield units were measured in the bladder, pelvic sidewall, and rectal shelf. For validation of the MAR interpolation algorithm, pelvis phantoms with small bladder "lesions" and metal hip prostheses were made, and images of the phantoms both with and without MAR reconstruction were evaluated. Image quality was significantly better with MAR reconstruction than without at all sites except the rectal shelf, where the image quality either had not changed or had worsened after MAR reconstruction. The mean attenuation value was changed after MAR reconstruction to its original expected value at the pelvic sidewall (p software with dual-energy CT decreases metal artifacts and increases diagnostic confidence in the assessment of the pelvic cavity but also introduces new artifacts that can obscure pelvic structures.

  19. Relevance of biotic pathways to the long-term regulation of nuclear waste disposal. Estimation of radiation dose to man resulting from biotic transport: the BIOPORT/MAXI1 software package. Volume 5

    Energy Technology Data Exchange (ETDEWEB)

    McKenzie, D.H.; Cadwell, L.L.; Gano, K.A.; Kennedy, W.E. Jr.; Napier, B.A.; Peloquin, R.A.; Prohammer, L.A.; Simmons, M.A.

    1985-10-01

    BIOPORT/MAXI1 is a collection of five computer codes designed to estimate the potential magnitude of the radiation dose to man resulting from biotic transport processes. Dose to man is calculated for ingestion of agricultural crops grown in contaminated soil, inhalation of resuspended radionuclides, and direct exposure to penetrating radiation resulting from the radionuclide concentrations established in the available soil surface by the biotic transport model. This document is designed as both an instructional and reference document for the BIOPORT/MAXI1 computer software package and has been written for two major audiences. The first audience includes persons concerned with the mathematical models of biological transport of commercial low-level radioactive wastes and the computer algorithms used to implement those models. The second audience includes persons concerned with exercising the computer program and exposure scenarios to obtain results for specific applications. The report contains sections describing the mathematical models, user operation of the computer programs, and program structure. Input and output for five sample problems are included. In addition, listings of the computer programs, data libraries, and dose conversion factors are provided in appendices.

  20. Relevance of biotic pathways to the long-term regulation of nuclear waste disposal. Estimation of radiation dose to man resulting from biotic transport: the BIOPORT/MAXI1 software package. Volume 5

    International Nuclear Information System (INIS)

    McKenzie, D.H.; Cadwell, L.L.; Gano, K.A.; Kennedy, W.E. Jr.; Napier, B.A.; Peloquin, R.A.; Prohammer, L.A.; Simmons, M.A.

    1985-10-01

    BIOPORT/MAXI1 is a collection of five computer codes designed to estimate the potential magnitude of the radiation dose to man resulting from biotic transport processes. Dose to man is calculated for ingestion of agricultural crops grown in contaminated soil, inhalation of resuspended radionuclides, and direct exposure to penetrating radiation resulting from the radionuclide concentrations established in the available soil surface by the biotic transport model. This document is designed as both an instructional and reference document for the BIOPORT/MAXI1 computer software package and has been written for two major audiences. The first audience includes persons concerned with the mathematical models of biological transport of commercial low-level radioactive wastes and the computer algorithms used to implement those models. The second audience includes persons concerned with exercising the computer program and exposure scenarios to obtain results for specific applications. The report contains sections describing the mathematical models, user operation of the computer programs, and program structure. Input and output for five sample problems are included. In addition, listings of the computer programs, data libraries, and dose conversion factors are provided in appendices

  1. Impact of metal artifact reduction software on image quality of gemstone spectral imaging dual-energy cerebral CT angiography after intracranial aneurysm clipping

    Energy Technology Data Exchange (ETDEWEB)

    Dunet, Vincent; Bernasconi, Martine; Hajdu, Steven David; Meuli, Reto Antoine; Zerlauth, Jean-Baptiste [Lausanne University Hospital, Department of Diagnostic and Interventional Radiology, Lausanne (Switzerland); Daniel, Roy Thomas [Lausanne University Hospital, Department of Neurosurgery, Lausanne (Switzerland)

    2017-09-15

    We aimed to assess the impact of metal artifact reduction software (MARs) on image quality of gemstone spectral imaging (GSI) dual-energy (DE) cerebral CT angiography (CTA) after intracranial aneurysm clipping. This retrospective study was approved by the institutional review board, which waived patient written consent. From January 2013 to September 2016, single source DE cerebral CTA were performed in 45 patients (mean age: 60 ± 9 years, male 9) after intracranial aneurysm clipping and reconstructed with and without MARs. Signal-to-noise (SNR), contrast-to-noise (CNR), and relative CNR (rCNR) ratios were calculated from attenuation values measured in the internal carotid artery (ICA) and middle cerebral artery (MCA). Volume of clip and artifacts and relative clip blurring reduction (rCBR) ratios were also measured at each energy level with/without MARs. Variables were compared between GSI and GSI-MARs using the paired Wilcoxon signed-rank test. MARs significantly reduced metal artifacts at all energy levels but 130 and 140 keV, regardless of clips' location and number. The optimal rCBR was obtained at 110 and 80 keV, respectively, on GSI and GSI-MARs images, with up to 96% rCNR increase on GSI-MARs images. The best compromise between metal artifact reduction and rCNR was obtained at 70-75 and 65-70 keV for GSI and GSI-MARs images, respectively, with up to 15% rCBR and rCNR increase on GSI-MARs images. MARs significantly reduces metal artifacts on DE cerebral CTA after intracranial aneurysm clipping regardless of clips' location and number. It may be used to reduce radiation dose while increasing CNR. (orig.)

  2. HOW THE ROCKY FLATS ENVIRONMENTAL TECHNOLOGY SITE DEVELOPED A NEW WASTE PACKAGE USING A POLYUREA COATING THAT IS SAFELY AND ECONOMICALLY ELIMINATING SIZE REDUCTION OF LARGE ITEMS

    International Nuclear Information System (INIS)

    Dorr, Kent A.; Hogue, Richard S.; Kimokeo, Margaret K.

    2003-01-01

    One of the major challenges involved in closing the Rocky Flats Environmental Technology Site (RFETS) is the disposal of extremely large pieces of contaminated production equipment and building debris. Past practice has been to size reduce the equipment into pieces small enough to fit into approved, standard waste containers. Size reducing this equipment is extremely expensive, and exposes workers to high-risk tasks, including significant industrial, chemical, and radiological hazards. RFETS has developed a waste package using a Polyurea coating for shipping large contaminated objects. The cost and schedule savings have been significant

  3. RASPLAV package

    International Nuclear Information System (INIS)

    1990-01-01

    The RASPLAV package for investigation of post-accident mass transport and heat transfer processes is presented. The package performs three dimensional thermal conduction calculations in space nonuniform and temperature dependent conductivities and variable heat sources, taking into account phase transformations. The processes of free-moving bulk material, mixing of melting fuel due to advection and dissolution, and also evaporation/adsorption are modelled. Two-dimensional hydrodynamics with self-consistent heat transfer are also performed. The paper briefly traces the ways the solution procedures are carried out in the program package and outlines the major results of the simulation of reactor vessel melting after a core meltdown. The theoretical analysis and the calculations in this case were carried out in order to define the possibility of localization of the zone reminders. The interactions between the reminders and the concrete are simulated and evaluation of the interaction parameters is carried out. 4 refs. (R.Ts)

  4. AN ADA NAMELIST PACKAGE

    Science.gov (United States)

    Klumpp, A. R.

    1994-01-01

    The Ada Namelist Package, developed for the Ada programming language, enables a calling program to read and write FORTRAN-style namelist files. A namelist file consists of any number of assignment statements in any order. Features of the Ada Namelist Package are: the handling of any combination of user-defined types; the ability to read vectors, matrices, and slices of vectors and matrices; the handling of mismatches between variables in the namelist file and those in the programmed list of namelist variables; and the ability to avoid searching the entire input file for each variable. The principle user benefits of this software are the following: the ability to write namelist-readable files, the ability to detect most file errors in the initialization phase, a package organization that reduces the number of instantiated units to a few packages rather than to many subprograms, a reduced number of restrictions, and an increased execution speed. The Ada Namelist reads data from an input file into variables declared within a user program. It then writes data from the user program to an output file, printer, or display. The input file contains a sequence of assignment statements in arbitrary order. The output is in namelist-readable form. There is a one-to-one correspondence between namelist I/O statements executed in the user program and variables read or written. Nevertheless, in the input file, mismatches are allowed between assignment statements in the file and the namelist read procedure statements in the user program. The Ada Namelist Package itself is non-generic. However, it has a group of nested generic packages following the nongeneric opening portion. The opening portion declares a variety of useraccessible constants, variables and subprograms. The subprograms are procedures for initializing namelists for reading, reading and writing strings. The subprograms are also functions for analyzing the content of the current dataset and diagnosing errors. Two nested

  5. SU-E-I-63: Quantitative Evaluation of the Effects of Orthopedic Metal Artifact Reduction (OMAR) Software On CT Images for Radiotherapy Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Jani, S [Sharp Memorial Hospital, San Diego, CA (United States)

    2014-06-01

    Purpose: CT simulation for patients with metal implants can often be challenging due to artifacts that obscure tumor/target delineation and normal organ definition. Our objective was to evaluate the effectiveness of Orthopedic Metal Artifact Reduction (OMAR), a commercially available software, in reducing metal-induced artifacts and its effect on computed dose during treatment planning. Methods: CT images of water surrounding metallic cylindrical rods made of aluminum, copper and iron were studied in terms of Hounsfield Units (HU) spread. Metal-induced artifacts were characterized in terms of HU/Volume Histogram (HVH) using the Pinnacle treatment planning system. Effects of OMAR on enhancing our ability to delineate organs on CT and subsequent dose computation were examined in nine (9) patients with hip implants and two (2) patients with breast tissue expanders. Results: Our study characterized water at 1000 HU with a standard deviation (SD) of about 20 HU. The HVHs allowed us to evaluate how the presence of metal changed the HU spread. For example, introducing a 2.54 cm diameter copper rod in water increased the SD in HU of the surrounding water from 20 to 209, representing an increase in artifacts. Subsequent use of OMAR brought the SD down to 78. Aluminum produced least artifacts whereas Iron showed largest amount of artifacts. In general, an increase in kVp and mA during CT scanning showed better effectiveness of OMAR in reducing artifacts. Our dose analysis showed that some isodose contours shifted by several mm with OMAR but infrequently and were nonsignificant in planning process. Computed volumes of various dose levels showed <2% change. Conclusions: In our experience, OMAR software greatly reduced the metal-induced CT artifacts for the majority of patients with implants, thereby improving our ability to delineate tumor and surrounding organs. OMAR had a clinically negligible effect on computed dose within tissues. Partially funded by unrestricted

  6. Petroleum software profiles

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    A profile of twenty-two software packages designed for petroleum exploration and production was provided. Some focussed on the oil and gas engineering industry, and others on mapping systems containing well history files and well data summaries. Still other programs provided accounting systems designed to address the complexities of the oil and gas industry. The software packages reviewed were developed by some of the best-known groups involved in software development for the oil and gas industry, including among others, Geoquest, the Can Tek Group, Applied Terravision Systems Inc., Neotechnology Consultants Ltd., (12) OGCI Software Inc., Oracle Energy, Production Revenue Information Systems Management, Virtual Computing Services Ltd., and geoLogic Systems Ltd

  7. Gammasphere software development. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Piercey, R.B.

    1994-01-01

    This report describes the activities of the nuclear physics group at Mississippi State University which were performed during 1993. Significant progress has been made in the focus areas: chairing the Gammasphere Software Working Group (SWG); assisting with the porting and enhancement of the ORNL UPAK histogramming software package; and developing standard formats for Gammasphere data products. In addition, they have established a new public ftp archive to distribute software and software development tools and information.

  8. A software program for exchanging MR data

    DEFF Research Database (Denmark)

    Ring, P B; Jensen, J A; Henriksen, O

    1993-01-01

    of digital MR images of the human brain. Because there was no common data format, software package was developed for data exchange. This article describes the basic features of the developed software. The software package was written in the language of C and was successfully tested on an IBM-6150 UNIX...... workstation. The software is currently being tested on the following series of UNIX workstations: SUN SPARC, IBM RS6000, and HP 9000/700....

  9. 76 FR 60939 - Metal Fatigue Analysis Performed by Computer Software

    Science.gov (United States)

    2011-09-30

    ... Software AGENCY: Nuclear Regulatory Commission. ACTION: Regulatory issue summary; request for comment... computer software package, WESTEMS TM , to demonstrate compliance with Section III, ``Rules for... Software Addressees All holders of, and applicants for, a power reactor operating license or construction...

  10. Criteria for the selection of ERP software

    Directory of Open Access Journals (Sweden)

    2007-01-01

    Full Text Available The implementation of an ERP software package is an important investment for an organization, which is characterized also by a high degree of risk. Selecting the most appropriate software is a necessary condition for a successful implementation. This paper is describing the major aspects of software selection in general and the relevant criteria in the case of ERP software.

  11. Software for Library Management: Selection and Evaluation.

    Science.gov (United States)

    Notowitz, Carol I.

    1987-01-01

    This discussion of library software packages includes guidelines for library automation with microcomputers; criteria to aid in software selection; comparison of some features of available acquisitions, circulation and overdues software; references for software reviews; additional information on microsoftware; and a directory of producers and…

  12. Analysis of metal artifact reduction tools for dental hardware in CT scans of the oral cavity: kVp, iterative reconstruction, dual-energy CT, metal artifact reduction software: does it make a difference?

    Energy Technology Data Exchange (ETDEWEB)

    Crop, An de; Hoof, Tom van; Herde, Katharina d' ; Thierens, Hubert; Bacher, Klaus [Ghent University, Department of Basic Medical Sciences, Gent (Belgium); Casselman, Jan; Vereecke, Elke; Bossu, Nicolas [AZ Sint Jan Bruges Ostend AV, Department of Radiology, Bruges (Belgium); Dierens, Melissa [Ghent University, Dental School, Unit for Oral and Maxillofacial Imaging, Ghent (Belgium); Pamplona, Jaime [Hospital Lisboa Central, Department of Neuroradiology, Lisbon (Portugal)

    2015-08-15

    Metal artifacts may negatively affect radiologic assessment in the oral cavity. The aim of this study was to evaluate different metal artifact reduction techniques for metal artifacts induced by dental hardware in CT scans of the oral cavity. Clinical image quality was assessed using a Thiel-embalmed cadaver. A Catphan phantom and a polymethylmethacrylate (PMMA) phantom were used to evaluate physical-technical image quality parameters such as artifact area, artifact index (AI), and contrast detail (IQF{sub inv}). Metal cylinders were inserted in each phantom to create metal artifacts. CT images of both phantoms and the Thiel-embalmed cadaver were acquired on a multislice CT scanner using 80, 100, 120, and 140 kVp; model-based iterative reconstruction (Veo); and synthesized monochromatic keV images with and without metal artifact reduction software (MARs). Four radiologists assessed the clinical image quality, using an image criteria score (ICS). Significant influence of increasing kVp and the use of Veo was found on clinical image quality (p = 0.007 and p = 0.014, respectively). Application of MARs resulted in a smaller artifact area (p < 0.05). However, MARs reconstructed images resulted in lower ICS. Of all investigated techniques, Veo shows to be most promising, with a significant improvement of both the clinical and physical-technical image quality without adversely affecting contrast detail. MARs reconstruction in CT images of the oral cavity to reduce dental hardware metallic artifacts is not sufficient and may even adversely influence the image quality. (orig.)

  13. Iterative software kernels

    Energy Technology Data Exchange (ETDEWEB)

    Duff, I.

    1994-12-31

    This workshop focuses on kernels for iterative software packages. Specifically, the three speakers discuss various aspects of sparse BLAS kernels. Their topics are: `Current status of user lever sparse BLAS`; Current status of the sparse BLAS toolkit`; and `Adding matrix-matrix and matrix-matrix-matrix multiply to the sparse BLAS toolkit`.

  14. Packaging LLW and ILW

    International Nuclear Information System (INIS)

    Flowers, R.H.; Owen, R.G.

    1991-01-01

    Low level waste (LLW) accounts for 70-80% by volume of all radioactive wastes produced by the nuclear industry. It has low specific activity, negligible actinide content and requires little, if any, shielding to protect workers. Volume reduction for LLW of high volume but low density may be achieved by incineration and compaction as appropriate, before packaging for disposal by near surface burial. Intermediate level waste (ILW) is treated and packed to convert it into a stable form to minimize any release of activity and make handling easier. The matrix chosen for immobilization, usually cement, polymers or bitumen, depends on the nature of the waste and the acceptance criteria of the disposal facility. The special case of LLW and ILW which will arise from reactor decommissioning is discussed. Packaging methods adopted by individual countries are reviewed. The range of costs involved for packaging ILW is indicated. There is no international consensus on the performance required from packaged waste to ensure its suitability both for interim storage and final disposal. (UK)

  15. Integrating commercial software in accelerator control- case study

    International Nuclear Information System (INIS)

    Pace, Alberto

    1994-01-01

    Using existing commercial software is the dream of any control system engineer for the development cost reduction that can reach one order of magnitude. This dream often vanishes when appears the requirement to have a uniform and consistent architecture through a wide number of components and applications. This makes it difficult to integrate several commercial packages that often impose different user interface and communication standards. This paper will describe the approach and standards that have been chosen for the CERN ISOLDE control system that have allowed several commercial packages to be integrated in the system as-they-are permitting the software development cost to be reduced to a minimum. (author). 10 refs., 2 tabs., 9 figs

  16. Software for microcircuit systems

    International Nuclear Information System (INIS)

    Kunz, P.F.

    1978-01-01

    Modern Large Scale Integration (LSI) microcircuits are meant to be programmed in order to control the function that they perform. In the previous paper the author has already discussed the basics of microprogramming and have studied in some detail two types of new microcircuits. In this paper, methods of developing software for these microcircuits are explored. This generally requires a package of support software in order to assemble the microprogram, and also some amount of support software to test the microprograms and to test the microprogrammed circuit itself. (Auth.)

  17. CO2 reduction in the Danish transportation sector. Working paper 10: Energy efficiency of the private cars - a package of control measures

    International Nuclear Information System (INIS)

    1997-03-01

    Average requirements to automotive fuel efficiency in new cars and differentiation of registration and weight taxes according to fuel consumption by a car result in fewer new cars due to very high registration tax and lower driving costs per km, which is against the CO 2 reduction measure. More efficient car manufacturing would eventually lead to a lower registration tax. Higher tax on fuels is another solution to the problem. (EG)

  18. A comparison of software programs to determine curie content

    International Nuclear Information System (INIS)

    Hansen, C.J.; Miller C.C.

    1995-01-01

    Commercial nuclear power plants have used various methods to determine the curie content of radwaste packages to comply with shipping and disposal regulations. Several computer software packages are available which can determine the curie content of a package based on the geometry of the package and the dose rate of the package provided a given source spectrum. This paper will compare three of the more commonly used software packages. A brief review of the selection and use of software programs at Diablo Canyon Power Plant for radwaste and radioactive material shipments will be provided. These software packages are the PAKRAD program by Bechtel (which utilizes EPRI DOSCON data), RAMSHP by WMG and MICROSHIELD by Grove Engineering. A comparison of the software packages in the calculation of curie content for a box of dry active waste and a cartridge filter will be presented. A summary of program limitations will also be provided

  19. Software needs engineering - a position paper

    OpenAIRE

    GRIMSON, JANE BARCLAY

    2000-01-01

    PUBLISHED When the general press refers to `software' in its headlines, then this is often not to relate a success story, but to expand on yet another `software-risk-turned-problem-story'. For many people, the term `software' evokes the image of an application package running either on a PC or some similar stand-alone usage. Over 70% of all software, however, are not developed in the traditional software houses as part of the creation of such packages. Much of this software comes in the fo...

  20. DTS : un logiciel d'aide à l'élaboration de modèles d'écoulement dans les réacteurs Dts: a Software Package for Flow Simulation in Reactors

    Directory of Open Access Journals (Sweden)

    Leclerc J. P.

    2006-11-01

    Full Text Available Cet article a pour but la présentation d'un logiciel d'aide à la construction de modèles d'écoulement à partir de la méthode des distributions de temps de séjour (DTS. La théorie des distributions de temps de séjour ainsi que des méthodes de traçage couramment utilisées sont rappelées. Une description du logiciel est ensuite effectuée. Le modèle est basé sur l'association de modules élémentaires (réacteur parfaitement agité, réacteur piston. . . , la détermination de la fonction de transfert étant effectuée en résolvant les bilans de matière dans l'espace de Laplace. Le logiciel peut donner la réponse à un signal d'entrée quelconque et plusieurs paramètres du modèle peuvent être optimisés. Différents couples de traceurs et de détecteurs sont donnés et les précautions à prendre lors des traçages sont décrites. Finalement, différentes études effectuées à l'aide du logiciel sont présentées afin de montrer les utilisations possibles. Improving the performance of an existing reactor or studying a new design requires modeling the flow of the different phases. Computational fluid dynamics can give an accurate a priori description of the velocity and concentration fields. However, this approach is too complicated in some cases (complicated geometry, random flow media, etc. , and this results in an abundance of information. A simpler approach relies on the theory of Residence Time Distribution (RTD, which is a theoretical interpretation framework for tracer experiments. This paper describes a software package that simulates hydrodynamic models derived from RTD experiments. The concept of RTD, introduced by Danckwerts in 1953, is briefly reviewed. Then tracer experiments, commonly used tracers and detectors are dealt with. Finally, the care required in tracer experiments is described in detail. Visual inspection of the tracer response makes it is possible to guess the main characteristics of the flow pattern

  1. Computing and software

    Directory of Open Access Journals (Sweden)

    White, G. C.

    2004-06-01

    Full Text Available The reality is that the statistical methods used for analysis of data depend upon the availability of software. Analysis of marked animal data is no different than the rest of the statistical field. The methods used for analysis are those that are available in reliable software packages. Thus, the critical importance of having reliable, up–to–date software available to biologists is obvious. Statisticians have continued to develop more robust models, ever expanding the suite of potential analysis methods available. But without software to implement these newer methods, they will languish in the abstract, and not be applied to the problems deserving them. In the Computers and Software Session, two new software packages are described, a comparison of implementation of methods for the estimation of nest survival is provided, and a more speculative paper about how the next generation of software might be structured is presented. Rotella et al. (2004 compare nest survival estimation with different software packages: SAS logistic regression, SAS non–linear mixed models, and Program MARK. Nests are assumed to be visited at various, possibly infrequent, intervals. All of the approaches described compute nest survival with the same likelihood, and require that the age of the nest is known to account for nests that eventually hatch. However, each approach offers advantages and disadvantages, explored by Rotella et al. (2004. Efford et al. (2004 present a new software package called DENSITY. The package computes population abundance and density from trapping arrays and other detection methods with a new and unique approach. DENSITY represents the first major addition to the analysis of trapping arrays in 20 years. Barker & White (2004 discuss how existing software such as Program MARK require that each new model’s likelihood must be programmed specifically for that model. They wishfully think that future software might allow the user to combine

  2. Lively package

    International Nuclear Information System (INIS)

    Jaremko, G.

    1997-01-01

    Progress on the Lloydminster Heavy Oil Interpretive Centre, sponsored by the Lloydminster Oilfield Technical Society and expected to open in late 1998, was discussed. Some $150,000 of the $750,000 budget is already in the bank, and another $150,000 is in the pipeline. The Centre will be added to an existing and well-established visitor's site. It is reported to contain a lively and imaginatively-designed exhibit package, and promises to become a combination of educational tool and tourist attraction for the town of Lloydminster, Saskatchewan, in the heart of heavy oil country

  3. Reflective Packaging

    Science.gov (United States)

    1994-01-01

    The aluminized polymer film used in spacecraft as a radiation barrier to protect both astronauts and delicate instruments has led to a number of spinoff applications. Among them are aluminized shipping bags, food cart covers and medical bags. Radiant Technologies purchases component materials and assembles a barrier made of layers of aluminized foil. The packaging reflects outside heat away from the product inside the container. The company is developing new aluminized lines, express mailers, large shipping bags, gel packs and insulated panels for the building industry.

  4. Software licenses: Stay honest!

    CERN Multimedia

    Computer Security Team

    2012-01-01

    Do you recall our article about copyright violation in the last issue of the CERN Bulletin, “Music, videos and the risk for CERN”? Now let’s be more precise. “Violating copyright” not only means the illegal download of music and videos, it also applies to software packages and applications.   Users must respect proprietary rights in compliance with the CERN Computing Rules (OC5). Not having legitimately obtained a program or the required licenses to run that software is not a minor offense. It violates CERN rules and puts the Organization at risk! Vendors deserve credit and compensation. Therefore, make sure that you have the right to use their software. In other words, you have bought the software via legitimate channels and use a valid and honestly obtained license. This also applies to “Shareware” and software under open licenses, which might also come with a cost. Usually, only “Freeware” is complete...

  5. Automated multispectra alpha spectrometer and data reduction system

    International Nuclear Information System (INIS)

    Hochel, R.C.

    1975-12-01

    A complete hardware and software package for the accumulation and rapid analysis of multiple alpha pulse height spectra has been developed. The system utilizes a 4096-channel analyzer capable of accepting up to sixteen inputs from solid-state surface barrier detectors via mixer-router modules. The analyzer is interfaced to a desk-top programmable calculator and thermal line printer. A chained software package including spectrum printout, peak analysis, plutonium-238 and plutonium-239 data reduction, and automatic energy calibration routines was written. With the chained program a complete printout, peak analysis, and plutonium data reduction of a 512-channel alpha spectrum are obtained in about three minutes with an accuracy within five percent of hand analyses

  6. HYPERDIRE. HYPERgeometric functions DIfferential REduction. MATEMATICA based packages for differential reduction of generalized hypergeometric functions. F{sub D} and F{sub S} Horn-type hypergeometric functions of three variables

    Energy Technology Data Exchange (ETDEWEB)

    Bytev, Vladimir V. [Joint Inst. for Nuclear Research, Dubna (Russian Federation); Kalmykov, Mikhail Yu. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Moch, Sven-Olaf [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik

    2013-12-15

    HYPERDIRE is a project devoted to the creation of a set of Mathematica based programs for the differential reduction of hypergeometric functions. The current version includes two parts: the first one, FdFunction, for manipulations with Appell hypergeometric functions F{sub D} of r variables; and the second one, FsFunction, for manipulations with Lauricella-Saran hypergeometric functions F{sub S} of three variables. Both functions are related with one-loop Feynman diagrams.

  7. HYPERDIRE. HYPERgeometric functions DIfferential REduction. MATHEMATICA based packages for differential reduction of generalized hypergeometric functions {sub p}F{sub p-1}, F{sub 1}, F{sub 2}, F{sub 3}, F{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Bytev, Vladimir V.; Kalmykov, Mikhail Yu. [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Joint Institute for Nuclear Research, Dubna (Russian Federation); Kniehl, Bernd A. [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik

    2013-05-15

    HYPERDIRE is a project devoted to the creation of a set of Mathematica based programs for the differential reduction of hypergeometric functions. The current version includes two parts: one, pfq, is relevant for manipulations of hypergeometric functions {sub p+1}F{sub p}, and the second one, AppellF1F4, for manipulations with Appell hypergeometric functions F{sub 1}, F{sub 2}, F{sub 3}, F{sub 4} of two variables.

  8. Solar Asset Management Software

    Energy Technology Data Exchange (ETDEWEB)

    Iverson, Aaron [Ra Power Management, Inc., Oakland, CA (United States); Zviagin, George [Ra Power Management, Inc., Oakland, CA (United States)

    2016-09-30

    Ra Power Management (RPM) has developed a cloud based software platform that manages the financial and operational functions of third party financed solar projects throughout their lifecycle. RPM’s software streamlines and automates the sales, financing, and management of a portfolio of solar assets. The software helps solar developers automate the most difficult aspects of asset management, leading to increased transparency, efficiency, and reduction in human error. More importantly, our platform will help developers save money by improving their operating margins.

  9. Design requirements for SRB production control system. Volume 3: Package evaluation, modification and hardware

    Science.gov (United States)

    1981-01-01

    The software package evaluation was designed to analyze commercially available, field-proven, production control or manufacturing resource planning management technology and software package. The analysis was conducted by comparing SRB production control software requirements and conceptual system design to software package capabilities. The methodology of evaluation and the findings at each stage of evaluation are described. Topics covered include: vendor listing; request for information (RFI) document; RFI response rate and quality; RFI evaluation process; and capabilities versus requirements.

  10. The development of a digital signal processing and plotting package to support testing of hazardous and radioactive material packages

    International Nuclear Information System (INIS)

    Ludwigsen, J.S.; Uncapher, W.L.; Arviso, M.; Lattier, C.N.; Hankinson, M.; Cannone, D.J.

    1995-01-01

    Federal regulations allow package designers to use analysis, testing, or a combination of analysis and testing to support certification of packages used to transport hazardous or radioactive materials. In recent years, many certified packages were subjected to a combination of analysis and testing. A major part of evaluating structural or thermal package response is the collection, reduction and presentation of instrumentation measurement data. Sandia National Laboratories, under the sponsorship of the US Department of Energy, has developed a comprehensive analysis and plotting package (known as KAPP) that performs digital signal processing of both transient structural and thermal data integrated with a comprehensive plotting package designed to support radioactive material package testing

  11. Science packages

    Science.gov (United States)

    1997-01-01

    Primary science teachers in Scotland have a new updating method at their disposal with the launch of a package of CDi (Compact Discs Interactive) materials developed by the BBC and the Scottish Office. These were a response to the claim that many primary teachers felt they had been inadequately trained in science and lacked the confidence to teach it properly. Consequently they felt the need for more in-service training to equip them with the personal understanding required. The pack contains five disks and a printed user's guide divided up as follows: disk 1 Investigations; disk 2 Developing understanding; disks 3,4,5 Primary Science staff development videos. It was produced by the Scottish Interactive Technology Centre (Moray House Institute) and is available from BBC Education at £149.99 including VAT. Free Internet distribution of science education materials has also begun as part of the Global Schoolhouse (GSH) scheme. The US National Science Teachers' Association (NSTA) and Microsoft Corporation are making available field-tested comprehensive curriculum material including 'Micro-units' on more than 80 topics in biology, chemistry, earth and space science and physics. The latter are the work of the Scope, Sequence and Coordination of High School Science project, which can be found at http://www.gsh.org/NSTA_SSandC/. More information on NSTA can be obtained from its Web site at http://www.nsta.org.

  12. Machine Tool Software

    Science.gov (United States)

    1988-01-01

    A NASA-developed software package has played a part in technical education of students who major in Mechanical Engineering Technology at William Rainey Harper College. Professor Hack has been using (APT) Automatically Programmed Tool Software since 1969 in his CAD/CAM Computer Aided Design and Manufacturing curriculum. Professor Hack teaches the use of APT programming languages for control of metal cutting machines. Machine tool instructions are geometry definitions written in APT Language to constitute a "part program." The part program is processed by the machine tool. CAD/CAM students go from writing a program to cutting steel in the course of a semester.

  13. Hazardous materials package performance regulations

    International Nuclear Information System (INIS)

    Russell, N.A.; Glass, R.E.; McClure, J.D.; Finley, N.C.

    1993-01-01

    Two regulatory philosophies, one based on 'specification' packaging standards and the other based on 'performance' packaging standards, currently define the hazmat packaging certification process. A main concern when setting performance standards is determining the appropriate standards necessary to assure adequate public protection. This paper discusses a Hazmat Packaging Performance Evaluation (HPPE) project being conducted at Sandia National Laboratories for the U.S. Department of Transportation Research and Special Programs Administration. In this project, the current bulk packagings (larger than 2000 gallons) for transporting Materials Extremely Toxic By Inhalation (METBI) are being evaluated and performance standards will be recommended. A computer software system, HazCon, has been developed which can calculate the dispersion of dense, neutral, and buoyant gases. HazCon also has a database of thermodynamic and toxicity data for the METBI materials, a user-friendly menu-driven format for creating input data sets for calculating dispersion of the METBI in the event of an accidental release, and a link between the METBI database and the dense gas dispersion code (which requires thermodynamic properties). The primary output of HazCon is a listing of mass concentrations of the released material at distances downwind from the release point. (J.P.N.)

  14. Real World Software Engineering

    Science.gov (United States)

    1994-07-15

    You put the new kid there and their first promotion is out of maintenance. ii Maintenance is not sufficiently emphasized as an important criteria for...the successful material from Koffman’s CS1 pedagogy with a software-engineering-oriented Ada presentation order. Packages are introduced early and...Shumate, K. Understanding Ada. 2nd edition, John Wiley & Sons. This would make a CS1 book if it included more overall pedagogy , independent of language

  15. User's Guide, software for reduction and analysis of daily weather and surface-water data: Tools for time series analysis of precipitation, temperature, and streamflow data

    Science.gov (United States)

    Hereford, Richard

    2006-01-01

    The software described here is used to process and analyze daily weather and surface-water data. The programs are refinements of earlier versions that include minor corrections and routines to calculate frequencies above a threshold on an annual or seasonal basis. Earlier versions of this software were used successfully to analyze historical precipitation patterns of the Mojave Desert and the southern Colorado Plateau regions, ecosystem response to climate variation, and variation of sediment-runoff frequency related to climate (Hereford and others, 2003; 2004; in press; Griffiths and others, 2006). The main program described here (Day_Cli_Ann_v5.3) uses daily data to develop a time series of various statistics for a user specified accounting period such as a year or season. The statistics include averages and totals, but the emphasis is on the frequency of occurrence in days of relatively rare weather or runoff events. These statistics are indices of climate variation; for a discussion of climate indices, see the Climate Research Unit website of the University of East Anglia (http://www.cru.uea.ac.uk/projects/stardex/) and the Climate Change Indices web site (http://cccma.seos.uvic.ca/ETCCDMI/indices.html). Specifically, the indices computed with this software are the frequency of high intensity 24-hour rainfall, unusually warm temperature, and unusually high runoff. These rare, or extreme events, are those greater than the 90th percentile of precipitation, streamflow, or temperature computed for the period of record of weather or gaging stations. If they cluster in time over several decades, extreme events may produce detectable change in the physical landscape and ecosystem of a given region. Although the software has been tested on a variety of data, as with any software, the user should carefully evaluate the results with their data. The programs were designed for the range of precipitation, temperature, and streamflow measurements expected in the semiarid

  16. Data Packages for the Hanford Immobilized Low-Activity Tank Waste Performance Assessment: 2001 Version

    International Nuclear Information System (INIS)

    MANN, F.M.

    2000-01-01

    Data package supporting the 2001 Immobilized Low-Activity Waste Performance Analysis. Geology, hydrology, geochemistry, facility, waste form, and dosimetry data based on recent investigation are provided. Verification and benchmarking packages for selected software codes are provided

  17. SCALE criticality safety verification and validation package

    International Nuclear Information System (INIS)

    Bowman, S.M.; Emmett, M.B.; Jordan, W.C.

    1998-01-01

    Verification and validation (V and V) are essential elements of software quality assurance (QA) for computer codes that are used for performing scientific calculations. V and V provides a means to ensure the reliability and accuracy of such software. As part of the SCALE QA and V and V plans, a general V and V package for the SCALE criticality safety codes has been assembled, tested and documented. The SCALE criticality safety V and V package is being made available to SCALE users through the Radiation Safety Information Computational Center (RSICC) to assist them in performing adequate V and V for their SCALE applications

  18. Software engineering

    CERN Document Server

    Sommerville, Ian

    2010-01-01

    The ninth edition of Software Engineering presents a broad perspective of software engineering, focusing on the processes and techniques fundamental to the creation of reliable, software systems. Increased coverage of agile methods and software reuse, along with coverage of 'traditional' plan-driven software engineering, gives readers the most up-to-date view of the field currently available. Practical case studies, a full set of easy-to-access supplements, and extensive web resources make teaching the course easier than ever.

  19. The School Advanced Ventilation Engineering Software (SAVES)

    Science.gov (United States)

    The School Advanced Ventilation Engineering Software (SAVES) package is a tool to help school designers assess the potential financial payback and indoor humidity control benefits of Energy Recovery Ventilation (ERV) systems for school applications.

  20. Gamma-Ray Spectrum Analysis Software GDA

    International Nuclear Information System (INIS)

    Wanabongse, P.

    1998-01-01

    The developmental work on computer software for gamma-ray spectrum analysis has been completed as a software package version 1.02 named GDA, which is an acronym for Gamma-spectrum Deconvolution and Analysis. The software package consists of three 3.5-inch diskettes for setup and a user's manual. GDA software can be installed for using on a personal computer with Windows 95 or Windows NT 4.0 operating system. A computer maybe the type of 80486 CPU with 8 megabytes of memory

  1. Development of a fatigue analysis software system

    International Nuclear Information System (INIS)

    Choi, B. I.; Lee, H. J.; Han, S. W.; Kim, J. Y.; Hwang, K. H.; Kang, J. Y.

    2001-01-01

    A general purpose fatigue analysis software to predict fatigue lives of mechanical components and structures was developed. This software has some characteristic features including functions of searching weak regions on the free surface in order to reduce computing time significantly, a database of fatigue properties for various materials, and an expert system which can assist any users to get more proper results. This software can be used in the environment consists of commercial finite element packages. Using the software developed fatigue analyses for a SAE keyhole specimen and an automobile knuckle were carried out. It was observed that the results were agree well with those from commercial packages

  2. A NEW EXHAUST VENTILATION SYSTEM DESIGN SOFTWARE

    Directory of Open Access Journals (Sweden)

    H. Asilian Mahabady

    2007-09-01

    Full Text Available A Microsoft Windows based ventilation software package is developed to reduce time-consuming and boring procedure of exhaust ventilation system design. This program Assure accurate and reliable air pollution control related calculations. Herein, package is tentatively named Exhaust Ventilation Design Software which is developed in VB6 programming environment. Most important features of Exhaust Ventilation Design Software that are ignored in formerly developed packages are Collector design and fan dimension data calculations. Automatic system balance is another feature of this package. Exhaust Ventilation Design Software algorithm for design is based on two methods: Balance by design (Static pressure balance and design by Blast gate. The most important section of software is a spreadsheet that is designed based on American Conference of Governmental Industrial Hygienists calculation sheets. Exhaust Ventilation Design Software is developed so that engineers familiar with American Conference of Governmental Industrial Hygienists datasheet can easily employ it for ventilation systems design. Other sections include Collector design section (settling chamber, cyclone, and packed tower, fan geometry and dimension data section, a unit converter section (that helps engineers to deal with units, a hood design section and a Persian HTML help. Psychometric correction is also considered in Exhaust Ventilation Design Software. In Exhaust Ventilation Design Software design process, efforts are focused on improving GUI (graphical user interface and use of programming standards in software design. Reliability of software has been evaluated and results show acceptable accuracy.

  3. The software quality control for gamma spectrometry

    International Nuclear Information System (INIS)

    Monte, L.

    1986-01-01

    One of major problems with wich the quality control program of an environmental measurements laboratory is confronted is the evaluation of the performances of software packages for the analysis of gamma-ray spectra. A program of tests for evaluating the performances of the software package (SPECTRAN-F, Canberra Inc.) used by our laboratory is being carried out. In this first paper the results of a preliminary study concerning the evaluation of the performance of the doublet analysis routine are presented

  4. Development of Emittance Analysis Software for Ion Beam Characterization

    International Nuclear Information System (INIS)

    Padilla, M.J.; Liu, Yuan

    2007-01-01

    Transverse beam emittance is a crucial property of charged particle beams that describes their angular and spatial spread. It is a figure of merit frequently used to determine the quality of ion beams, the compatibility of an ion beam with a given beam transport system, and the ability to suppress neighboring isotopes at on-line mass separator facilities. Generally, a high-quality beam is characterized by a small emittance. In order to determine and improve the quality of ion beams used at the Holifield Radioactive Ion Beam Facility (HRIBF) for nuclear physics and nuclear astrophysics research, the emittances of the ion beams are measured at the off-line Ion Source Test Facilities. In this project, emittance analysis software was developed to perform various data processing tasks for noise reduction, to evaluate root-mean-square emittance, Twiss parameters, and area emittance of different beam fractions. The software also provides 2D and 3D graphical views of the emittance data, beam profiles, emittance contours, and RMS. Noise exclusion is essential for accurate determination of beam emittance values. A Self-Consistent, Unbiased Elliptical Exclusion (SCUBEEx) method is employed. Numerical data analysis techniques such as interpolation and nonlinear fitting are also incorporated into the software. The software will provide a simplified, fast tool for comprehensive emittance analysis. The main functions of the software package have been completed. In preliminary tests with experimental emittance data, the analysis results using the software were shown to be accurate

  5. DEVELOPMENT OF EMITTANCE ANALYSIS SOFTWARE FOR ION BEAM CHARACTERIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Padilla, M. J.; Liu, Y.

    2007-01-01

    Transverse beam emittance is a crucial property of charged particle beams that describes their angular and spatial spread. It is a fi gure of merit frequently used to determine the quality of ion beams, the compatibility of an ion beam with a given beam transport system, and the ability to suppress neighboring isotopes at on-line mass separator facilities. Generally a high quality beam is characterized by a small emittance. In order to determine and improve the quality of ion beams used at the Holifi eld Radioactive Ion beam Facility (HRIBF) for nuclear physics and nuclear astrophysics research, the emittances of the ion beams are measured at the off-line Ion Source Test Facilities. In this project, emittance analysis software was developed to perform various data processing tasks for noise reduction, to evaluate root-mean-square emittance, Twiss parameters, and area emittance of different beam fractions. The software also provides 2D and 3D graphical views of the emittance data, beam profi les, emittance contours, and RMS. Noise exclusion is essential for accurate determination of beam emittance values. A Self-Consistent, Unbiased Elliptical Exclusion (SCUBEEx) method is employed. Numerical data analysis techniques such as interpolation and nonlinear fi tting are also incorporated into the software. The software will provide a simplifi ed, fast tool for comprehensive emittance analysis. The main functions of the software package have been completed. In preliminary tests with experimental emittance data, the analysis results using the software were shown to be accurate.

  6. Ceramic ball grid array package stress analysis

    Science.gov (United States)

    Badri, S. H. B. S.; Aziz, M. H. A.; Ong, N. R.; Sauli, Z.; Alcain, J. B.; Retnasamy, V.

    2017-09-01

    The ball grid array (BGA), a form of chip scale package (CSP), was developed as one of the most advanced surface mount devices, which may be assembled by an ordinary surface ball bumps are used instead of plated nickel and gold (Ni/Au) bumps. Assembly and reliability of the BGA's printed circuit board (PCB), which is soldered by conventional surface mount technology is considered in this study. The Ceramic Ball Grid Array (CBGA) is a rectangular ceramic package or square-shaped that will use the solder ball for external electrical connections instead of leads or wire for connections. The solder balls will be arranged in an array or grid at the bottom of the ceramic package body. In this study, ANSYS software is used to investigate the stress on the package for 2 balls and 4 balls of the CBGA package with the various force range of 1-3 Newton applied to the top of the die, top of the substrate and side of the substrate. The highest maximum stress was analyzed and the maximum equivalent stress was observed on the solder ball and the die. From the simulation result, the CBGA package with less solder balls experience higher stress compared to the package with many solder balls. Therefore, less number of solder ball on the CBGA package results higher stress and critically affect the reliability of the solder balls itself, substrate and die which can lead to the solder crack and also die crack.

  7. Waste package performance assessment

    International Nuclear Information System (INIS)

    Lester, D.H.

    1981-01-01

    This paper describes work undertaken to assess the life-expectancy and post-failure nuclide release behavior of high-level and waste packages in a geologic repository. The work involved integrating models of individual phenomena (such as heat transfer, corrosion, package deformation, and nuclide transport) and using existing data to make estimates of post-emplacement behavior of waste packages. A package performance assessment code was developed to predict time to package failure in a flooded repository and subsequent transport of nuclides out of the leaking package. The model has been used to evaluate preliminary package designs. The results indicate, that within the limitation of model assumptions and data base, packages lasting a few hundreds of years could be developed. Very long lived packages may be possible but more comprehensive data are needed to confirm this

  8. The Potential Role of Grid-Like Software in Bedside Chest Radiography in Improving Image Quality and Dose Reduction: An Observer Preference Study.

    Science.gov (United States)

    Ahn, Su Yeon; Chae, Kum Ju; Goo, Jin Mo

    2018-01-01

    To compare the observer preference of image quality and radiation dose between non-grid, grid-like, and grid images. Each of the 38 patients underwent bedside chest radiography with and without a grid. A grid-like image was generated from a non-grid image using SimGrid software (Samsung Electronics Co. Ltd.) employing deep-learning-based scatter correction technology. Two readers recorded the preference for 10 anatomic landmarks and the overall appearance on a five-point scale for a pair of non-grid and grid-like images, and a pair of grid-like and grid images, respectively, which were randomly presented. The dose area product (DAP) was also recorded. Wilcoxon's rank sum test was used to assess the significance of preference. Both readers preferred grid-like images to non-grid images significantly ( p software significantly improved the image quality of non-grid images to a level comparable to that of grid images with a relatively lower level of radiation exposure.

  9. Evaluation of Agricultural Accounting Software. Improved Decision Making. Third Edition.

    Science.gov (United States)

    Lovell, Ashley C., Comp.

    Following a discussion of the evaluation criteria for choosing accounting software, this guide contains reviews of 27 accounting software programs that could be used by farm or ranch business managers. The information in the reviews was provided by the software vendors and covers the following points for each software package: general features,…

  10. SOFTWARE OPEN SOURCE, SOFTWARE GRATIS?

    Directory of Open Access Journals (Sweden)

    Nur Aini Rakhmawati

    2006-01-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 Berlakunya Undang – undang Hak Atas Kekayaan Intelektual (HAKI, memunculkan suatu alternatif baru untuk menggunakan software open source. Penggunaan software open source menyebar seiring dengan isu global pada Information Communication Technology (ICT saat ini. Beberapa organisasi dan perusahaan mulai menjadikan software open source sebagai pertimbangan. Banyak konsep mengenai software open source ini. Mulai dari software yang gratis sampai software tidak berlisensi. Tidak sepenuhnya isu software open source benar, untuk itu perlu dikenalkan konsep software open source mulai dari sejarah, lisensi dan bagaimana cara memilih lisensi, serta pertimbangan dalam memilih software open source yang ada. Kata kunci :Lisensi, Open Source, HAKI

  11. The particle tracking package Kassiopeia

    Energy Technology Data Exchange (ETDEWEB)

    Groh, Stefan [Karlsruhe Institute of Technology (Germany); Collaboration: KATRIN-Collaboration

    2016-07-01

    The Kassiopeia particle tracking framework is an object-oriented software package utilizing modern C++ techniques, written originally to meet the needs of the Katrin collaboration. Kassiopeia's target consists of simulating particle trajectories governed by arbitrarily complex differential equations of motion, continuous physics processes that may in part be modeled as terms perturbing that equation of motion, stochastic processes that occur in flight such as bulk scattering and decay, and potentially stochastic surface processes occurring at interfaces, including transmission and reflection effects. This entire set of computations takes place against the backdrop of a fully-featured geometry package which serves a variety of roles, including initialization of electromagnetic field simulations, gas flow simulations, and the support of state-dependent algorithm-swapping and behavioral changes. Kassiopeia has been well validated and widely used within the Katrin collaboration, playing a primary role in many theses and refereed publications.

  12. Packaging for Food Service

    Science.gov (United States)

    Stilwell, E. J.

    1985-01-01

    Most of the key areas of concern in packaging the three principle food forms for the space station were covered. It can be generally concluded that there are no significant voids in packaging materials availability or in current packaging technology. However, it must also be concluded that the process by which packaging decisions are made for the space station feeding program will be very synergistic. Packaging selection will depend heavily on the preparation mechanics, the preferred presentation and the achievable disposal systems. It will be important that packaging be considered as an integral part of each decision as these systems are developed.

  13. Waste Package Lifting Calculation

    International Nuclear Information System (INIS)

    H. Marr

    2000-01-01

    The objective of this calculation is to evaluate the structural response of the waste package during the horizontal and vertical lifting operations in order to support the waste package lifting feature design. The scope of this calculation includes the evaluation of the 21 PWR UCF (pressurized water reactor uncanistered fuel) waste package, naval waste package, 5 DHLW/DOE SNF (defense high-level waste/Department of Energy spent nuclear fuel)--short waste package, and 44 BWR (boiling water reactor) UCF waste package. Procedure AP-3.12Q, Revision 0, ICN 0, calculations, is used to develop and document this calculation

  14. Software Epistemology

    Science.gov (United States)

    2016-03-01

    in-vitro decision to incubate a startup, Lexumo [7], which is developing a commercial Software as a Service ( SaaS ) vulnerability assessment...LTS Label Transition System MUSE Mining and Understanding Software Enclaves RTEMS Real-Time Executive for Multi-processor Systems SaaS Software ...as a Service SSA Static Single Assignment SWE Software Epistemology UD/DU Def-Use/Use-Def Chains (Dataflow Graph)

  15. Software For Computing Selected Functions

    Science.gov (United States)

    Grant, David C.

    1992-01-01

    Technical memorandum presents collection of software packages in Ada implementing mathematical functions used in science and engineering. Provides programmer with function support in Pascal and FORTRAN, plus support for extended-precision arithmetic and complex arithmetic. Valuable for testing new computers, writing computer code, or developing new computer integrated circuits.

  16. Tired of Teaching Software Applications?

    Science.gov (United States)

    Lippert, Susan K.; Granger, Mary J.

    Many university business schools have an instructor-led course introducing computer software application packages. This course is often required for all undergraduates and is a prerequisite to other courses, such as accounting, finance, marketing, and operations management. Knowledge and skills gained in this course should enable students not only…

  17. Multiphysics software and the challenge to validating physical models

    International Nuclear Information System (INIS)

    Luxat, J.C.

    2008-01-01

    This paper discusses multi physics software and validation of physical models in the nuclear industry. The major challenge is to convert the general purpose software package to a robust application-specific solution. This requires greater knowledge of the underlying solution techniques and the limitations of the packages. Good user interfaces and neat graphics do not compensate for any deficiencies

  18. Programming task packages: Peach exchange format

    NARCIS (Netherlands)

    Verhoeff, T.

    2008-01-01

    Programming education and contests have introduced software to help evaluation by executing submitted taskwork. We present the notion of a task package as a unit for collecting, storing, archiving, and exchanging all information concerning a programming task. We also describe a specific format for

  19. Software reliability

    CERN Document Server

    Bendell, A

    1986-01-01

    Software Reliability reviews some fundamental issues of software reliability as well as the techniques, models, and metrics used to predict the reliability of software. Topics covered include fault avoidance, fault removal, and fault tolerance, along with statistical methods for the objective assessment of predictive accuracy. Development cost models and life-cycle cost models are also discussed. This book is divided into eight sections and begins with a chapter on adaptive modeling used to predict software reliability, followed by a discussion on failure rate in software reliability growth mo

  20. Merganser Download Package

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data download package contains an Esri 10.0 MXD, file geodatabase and copy of this FGDC metadata record. The data in this package are used in support of the...

  1. Creative Thinking Package

    Science.gov (United States)

    Jones, Clive

    1972-01-01

    A look at the latest package from a British managment training organization, which explains and demonstrates creative thinking techniques, including brainstorming. The package, designed for groups of twelve or more, consists of tapes, visuals, and associated exercises. (Editor/JB)

  2. Computer software.

    Science.gov (United States)

    Rosenthal, L E

    1986-10-01

    Software is the component in a computer system that permits the hardware to perform the various functions that a computer system is capable of doing. The history of software and its development can be traced to the early nineteenth century. All computer systems are designed to utilize the "stored program concept" as first developed by Charles Babbage in the 1850s. The concept was lost until the mid-1940s, when modern computers made their appearance. Today, because of the complex and myriad tasks that a computer system can perform, there has been a differentiation of types of software. There is software designed to perform specific business applications. There is software that controls the overall operation of a computer system. And there is software that is designed to carry out specialized tasks. Regardless of types, software is the most critical component of any computer system. Without it, all one has is a collection of circuits, transistors, and silicone chips.

  3. Packaging Printing Today

    OpenAIRE

    Stanislav Bolanča; Igor Majnarić; Kristijan Golubović

    2015-01-01

    Printing packaging covers today about 50% of all the printing products. Among the printing products there are printing on labels, printing on flexible packaging, printing on folding boxes, printing on the boxes of corrugated board, printing on glass packaging, synthetic and metal ones. The mentioned packaging are printed in flexo printing technique, offset printing technique, intaglio halftone process, silk – screen printing, ink ball printing, digital printing and hybrid printing process. T...

  4. Genome packaging in viruses

    OpenAIRE

    Sun, Siyang; Rao, Venigalla B.; Rossmann, Michael G.

    2010-01-01

    Genome packaging is a fundamental process in a viral life cycle. Many viruses assemble preformed capsids into which the genomic material is subsequently packaged. These viruses use a packaging motor protein that is driven by the hydrolysis of ATP to condense the nucleic acids into a confined space. How these motor proteins package viral genomes had been poorly understood until recently, when a few X-ray crystal structures and cryo-electron microscopy structures became available. Here we discu...

  5. Trends in Food Packaging.

    Science.gov (United States)

    Ott, Dana B.

    1988-01-01

    This article discusses developments in food packaging, processing, and preservation techniques in terms of packaging materials, technologies, consumer benefits, and current and potential food product applications. Covers implications due to consumer life-style changes, cost-effectiveness of packaging materials, and the ecological impact of…

  6. ACTS: from ATLAS software towards a common track reconstruction software

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00349786; The ATLAS collaboration; Salzburger, Andreas; Kiehn, Moritz; Hrdinka, Julia; Calace, Noemi

    2017-01-01

    Reconstruction of charged particles' trajectories is a crucial task for most particle physics experiments. The high instantaneous luminosity achieved at the LHC leads to a high number of proton-proton collisions per bunch crossing, which has put the track reconstruction software of the LHC experiments through a thorough test. Preserving track reconstruction performance under increasingly difficult experimental conditions, while keeping the usage of computational resources at a reasonable level, is an inherent problem for many HEP experiments. Exploiting concurrent algorithms and using multivariate techniques for track identification are the primary strategies to achieve that goal. Starting from current ATLAS software, the ACTS project aims to encapsulate track reconstruction software into a generic, framework- and experiment-independent software package. It provides a set of high-level algorithms and data structures for performing track reconstruction tasks as well as fast track simulation. The software is de...

  7. Comparison of computed tomography dose reporting software

    International Nuclear Information System (INIS)

    Abdullah, A.; Sun, Z.; Pongnapang, N.; Ng, K. H.

    2008-01-01

    Computed tomography (CT) dose reporting software facilitates the estimation of doses to patients undergoing CT examinations. In this study, comparison of three software packages, i.e. CT-Expo (version 1.5, Medizinische Hochschule, Hannover (Germany)), ImPACT CT Patients Dosimetry Calculator (version 0.99x, Imaging Performance Assessment on Computed Tomography, www.impactscan.org) and WinDose (version 2.1a, Wellhofer Dosimetry, Schwarzenbruck (Germany)), has been made in terms of their calculation algorithm and the results of calculated doses. Estimations were performed for head, chest, abdominal and pelvic examinations based on the protocols recommended by European guidelines using single-slice CT (SSCT) (Siemens Somatom Plus 4, Erlangen (Germany)) and multi-slice CT (MSCT) (Siemens Sensation 16, Erlangen (Germany)) for software-based female and male phantoms. The results showed that there are some differences in final dose reporting provided by these software packages. There are deviations of effective doses produced by these software packages. Percentages of coefficient of variance range from 3.3 to 23.4 % in SSCT and from 10.6 to 43.8 % in MSCT. It is important that researchers state the name of the software that is used to estimate the various CT dose quantities. Users must also understand the equivalent terminologies between the information obtained from the CT console and the software packages in order to use the software correctly. (authors)

  8. Development of an integrated energy concept: Assessment of the potential in the reduction of emissions of climate effective trace gases in the field of rational energy use for the old Laender. Appendix Vol. 5. Software programme PROTOS. General description and manual

    International Nuclear Information System (INIS)

    Hanke, T.

    1993-11-01

    In most cases the software engineer does not have a specific knowledge of the corresponding field of application. One of the main reason for the difficulty in producing the software is the fact that at first a common model of the software system has to be elaborated with the user by determining precisely the requirements. The dialogue is very demanding due to the different knowledge and a different accustomed way of thinking. The possibilities for a modelling are reduced by the efficiency and non-functional parameters for the determination of the requirements. Thus the necessity arises to lower the barrier between modelling and programming by an appropriate tool support and to accelerate the production of a prototype by the user itself. Quick production signifies that the specifications can immediately be realised, tested and serviced due to special requirements. This idea was the reason to develop a software product, that is not bound to modelling guidelines and does not require expensive development phases, i. e. a modelling of a problem according to a schedule already results in the software specification itself. According to this central idea a tool package has been developed in the frame of this project. The package is called PROTOS. (orig./UA) [de

  9. 49 CFR 173.28 - Reuse, reconditioning and remanufacture of packagings.

    Science.gov (United States)

    2010-10-01

    ... and limitations: (1) A non-bulk packaging which, upon inspection, shows evidence of a reduction in... than fiberboard), plastic film, or textile are not authorized for reuse; (4) Metal and plastic drums... metal packagings) or minimum (for plastic packagings) thickness of the packaging material, as required...

  10. Active Packaging Coatings

    Directory of Open Access Journals (Sweden)

    Luis J. Bastarrachea

    2015-11-01

    Full Text Available Active food packaging involves the packaging of foods with materials that provide an enhanced functionality, such as antimicrobial, antioxidant or biocatalytic functions. This can be achieved through the incorporation of active compounds into the matrix of the commonly used packaging materials, or by the application of coatings with the corresponding functionality through surface modification. The latter option offers the advantage of preserving the packaging materials’ bulk properties nearly intact. Herein, different coating technologies like embedding for controlled release, immobilization, layer-by-layer deposition, and photografting are explained and their potential application for active food packaging is explored and discussed.

  11. Advancements in meat packaging.

    Science.gov (United States)

    McMillin, Kenneth W

    2017-10-01

    Packaging of meat provides the same or similar benefits for raw chilled and processed meats as other types of food packaging. Although air-permeable packaging is most prevalent for raw chilled red meat, vacuum and modified atmosphere packaging offer longer shelf life. The major advancements in meat packaging have been in the widely used plastic polymers while biobased materials and their integration into composite packaging are receiving much attention for functionality and sustainability. At this time, active and intelligent packaging are not widely used for antioxidant, antimicrobial, and other functions to stabilize and enhance meat properties although many options are being developed and investigated. The advances being made in nanotechnology will be incorporated into food packaging and presumably into meat packaging when appropriate and useful. Intelligent packaging using sensors for transmission of desired information and prompting of subsequent changes in packaging materials, environments or the products to maintain safety and quality are still in developmental stages. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Edible packaging materials.

    Science.gov (United States)

    Janjarasskul, Theeranun; Krochta, John M

    2010-01-01

    Research groups and the food and pharmaceutical industries recognize edible packaging as a useful alternative or addition to conventional packaging to reduce waste and to create novel applications for improving product stability, quality, safety, variety, and convenience for consumers. Recent studies have explored the ability of biopolymer-based food packaging materials to carry and control-release active compounds. As diverse edible packaging materials derived from various by-products or waste from food industry are being developed, the dry thermoplastic process is advancing rapidly as a feasible commercial edible packaging manufacturing process. The employment of nanocomposite concepts to edible packaging materials promises to improve barrier and mechanical properties and facilitate effective incorporation of bioactive ingredients and other designed functions. In addition to the need for a more fundamental understanding to enable design to desired specifications, edible packaging has to overcome challenges such as regulatory requirements, consumer acceptance, and scaling-up research concepts to commercial applications.

  13. Software Defined Coded Networking

    DEFF Research Database (Denmark)

    Di Paola, Carla; Roetter, Daniel Enrique Lucani; Palazzo, Sergio

    2017-01-01

    the quality of each link and even across neighbouring links and using simulations to show that an additional reduction of packet transmission in the order of 40% is possible. Second, to advocate for the use of network coding (NC) jointly with software defined networking (SDN) providing an implementation...

  14. TOUGH2 software qualification

    International Nuclear Information System (INIS)

    Pruess, K.; Simmons, A.; Wu, Y.S.; Moridis, G.

    1996-02-01

    TOUGH2 is a numerical simulation code for multi-dimensional coupled fluid and heat flow of multiphase, multicomponent fluid mixtures in porous and fractured media. It belongs to the MULKOM (open-quotes MULti-KOMponentclose quotes) family of codes and is a more general version of the TOUGH simulator. The MULKOM family of codes was originally developed with a focus on geothermal reservoir simulation. They are suited to modeling systems which contain different fluid mixtures, with applications to flow problems arising in the context of high-level nuclear waste isolation, oil and gas recovery and storage, and groundwater resource protection. TOUGH2 is essentially a subset of MULKOM, consisting of a selection of the better tested and documented MULKOM program modules. The purpose of this package of reports is to provide all software baseline documents necessary for the software qualification of TOUGH2

  15. TOUGH2 software qualification

    Energy Technology Data Exchange (ETDEWEB)

    Pruess, K.; Simmons, A.; Wu, Y.S.; Moridis, G.

    1996-02-01

    TOUGH2 is a numerical simulation code for multi-dimensional coupled fluid and heat flow of multiphase, multicomponent fluid mixtures in porous and fractured media. It belongs to the MULKOM ({open_quotes}MULti-KOMponent{close_quotes}) family of codes and is a more general version of the TOUGH simulator. The MULKOM family of codes was originally developed with a focus on geothermal reservoir simulation. They are suited to modeling systems which contain different fluid mixtures, with applications to flow problems arising in the context of high-level nuclear waste isolation, oil and gas recovery and storage, and groundwater resource protection. TOUGH2 is essentially a subset of MULKOM, consisting of a selection of the better tested and documented MULKOM program modules. The purpose of this package of reports is to provide all software baseline documents necessary for the software qualification of TOUGH2.

  16. Software for Adapting Dspz Receivers to the Uran Interferometer Network

    Science.gov (United States)

    Isaeva, E. A.; Lytvynenko, O. A.; Shepelev, V. A.

    More than 10 years ago, URAN interferometer network (Megn A.V.,1997; Konovalenko A.A., 2014) had been equipped with newly designed receivers with a pass band extended up to 250 kHz and software rejection of interferences (Rashkovskii, 2012). The broadening of bandwidth of received signal increase the sensitivity of the receivers significantly and let us to investigate the angular structure about one hundred radio sources. A software package had been developed that allows: preparing a program of observations, carrying out observations automatically, making data cross-correlation, calculating visibility functions for all pairs of antennae, and fitting models of an angular structure of the sources. Data storage formats were elaborated for each stage of recording or processing. At present, new digital radio astronomy receiver DSPZ have been developed by IRA NASU (Zakharenko, 2016). The receiver allows recording an entire bandwidth of signals of a decameter range from 8 to 32 MHz. It is used at UTR-2 and URAN radio telescopes operated in a single dish mode. Application of the receivers for interferometer observation with the URAN network provides additional advantages in accuracy and sensitivity of studies. In this report we consider the data formats and synchronization methods used in URAN equipment and DSPZ receivers, and discuss algorithms of their transformation. Newly elaborated software is described, that allows selecting a set of frequency bands of signals recorded with DSPZ and converting them to the form used by the URAN software. This approach allows us to carry out the interferometer observations in an the extended frequency range provided by DSPZ and to use as much as possible the software package developed for the URAN network for data reduction.

  17. Collection Of Software For Computer Graphics

    Science.gov (United States)

    Hibbard, Eric A.; Makatura, George

    1990-01-01

    Ames Research Graphics System (ARCGRAPH) collection of software libraries and software utilities assisting researchers in generating, manipulating, and visualizing graphical data. Defines metafile format containing device-independent graphical data. File format used with various computer-graphics-manipulation and -animation software packages at Ames, including SURF (COSMIC Program ARC-12381) and GAS (COSMIC Program ARC-12379). Consists of two-stage "pipeline" used to put out graphical primitives. ARCGRAPH libraries developed on VAX computer running VMS.

  18. Software Library for Bruker TopSpin NMR Data Files

    Energy Technology Data Exchange (ETDEWEB)

    2016-10-14

    A software library for parsing and manipulating frequency-domain data files that have been processed using the Bruker TopSpin NMR software package. In the context of NMR, the term "processed" indicates that the end-user of the Bruker TopSpin NMR software package has (a) Fourier transformed the raw, time-domain data (the Free Induction Decay) into the frequency-domain and (b) has extracted the list of NMR peaks.

  19. Savannah River Plant Californium-252 Shuffler software manual

    International Nuclear Information System (INIS)

    Johnson, S.S.; Crane, T.W.; Eccleston, G.W.

    1979-03-01

    A software manual for operating the Savannah River Plant Shuffler nondestructive assay instrument is presented. The procedures for starting up the instrument, making assays, calibrating, and checking the performance of the hardware units are described. A list of the error messages with an explanation of the circumstances prompting the message and possible corrective measures is given. A summary of the software package is included showing the names and contents of the files and subroutines. The procedure for modifying the software package is outlined

  20. Reuse and recycling of radioactive material packaging

    International Nuclear Information System (INIS)

    Gerulis, Eduardo; Zapparoli, Carlos Leonel; Barboza, Marycel Figols de

    2009-01-01

    Human development is directly linked to energy consumption. The political decisions (to this human development) result in economic, social and environmental aspects, whose magnitude should maintain the sustainability of every aspect for not to collapsing. The environmental aspect has been a target of research because of the excessive emission of gases which contributes to the greenhouse effect. The production processes emit gases due to the consumption of energy to get it, but it is necessary to maintain the environmental sustainability in order to minimize the contribution to the emission of greenhouse gases. The population control and the energetic efficiency are factors that contribute to the environmental sustainability. Besides them, the culture of consumption is another factor that, when applied to the reduction of emissions, also contributes to the sustainability of the environment. The reuse of materials is one of the sub-factors which contribute to the reduction of emissions. The Radiopharmacy Directory (DIRF) at IPEN-CNEN/SP, produces radiopharmaceuticals that are necessary to improve the Brazilian population's life quality. The radiopharmaceuticals are transported in packaging to the transport of radioactive material. These packages are considered non-biodegradable, because some metals, which make up these packages, pollute the environment. These packages have increased costs, in addition, because it must be approved in tests of integrity. The reuse of packaging in favorable situations to the same purpose is a way to help the environment degradation and costs reduction. The packaging reuse in unfavorable situations disobey rules or return logistics that become effective the transport back, but the consumption culture strengthening can change this situation. This paper describes IPEN's packaging, form and quantities distribution, and the packaging that comes back to be reused. (author)

  1. Fragman: an R package for fragment analysis.

    Science.gov (United States)

    Covarrubias-Pazaran, Giovanny; Diaz-Garcia, Luis; Schlautman, Brandon; Salazar, Walter; Zalapa, Juan

    2016-04-21

    Determination of microsatellite lengths or other DNA fragment types is an important initial component of many genetic studies such as mutation detection, linkage and quantitative trait loci (QTL) mapping, genetic diversity, pedigree analysis, and detection of heterozygosity. A handful of commercial and freely available software programs exist for fragment analysis; however, most of them are platform dependent and lack high-throughput applicability. We present the R package Fragman to serve as a freely available and platform independent resource for automatic scoring of DNA fragment lengths diversity panels and biparental populations. The program analyzes DNA fragment lengths generated in Applied Biosystems® (ABI) either manually or automatically by providing panels or bins. The package contains additional tools for converting the allele calls to GenAlEx, JoinMap® and OneMap software formats mainly used for genetic diversity and generating linkage maps in plant and animal populations. Easy plotting functions and multiplexing friendly capabilities are some of the strengths of this R package. Fragment analysis using a unique set of cranberry (Vaccinium macrocarpon) genotypes based on microsatellite markers is used to highlight the capabilities of Fragman. Fragman is a valuable new tool for genetic analysis. The package produces equivalent results to other popular software for fragment analysis while possessing unique advantages and the possibility of automation for high-throughput experiments by exploiting the power of R.

  2. Data Packages for the Hanford Immobilized Low Activity Tank Waste Performance Assessment 2001 Version [SEC 1 THRU 5

    Energy Technology Data Exchange (ETDEWEB)

    MANN, F.M.

    2000-03-02

    Data package supporting the 2001 Immobilized Low-Activity Waste Performance Analysis. Geology, hydrology, geochemistry, facility, waste form, and dosimetry data based on recent investigation are provided. Verification and benchmarking packages for selected software codes are provided.

  3. Software Innovation

    DEFF Research Database (Denmark)

    Rose, Jeremy

      Innovation is the forgotten key to modern systems development - the element that defines the enterprising engineer, the thriving software firm and the cutting edge software application.  Traditional forms of technical education pay little attention to creativity - often encouraging overly...

  4. Software engineering

    CERN Document Server

    Sommerville, Ian

    2016-01-01

    For courses in computer science and software engineering The Fundamental Practice of Software Engineering Software Engineering introduces readers to the overwhelmingly important subject of software programming and development. In the past few years, computer systems have come to dominate not just our technological growth, but the foundations of our world's major industries. This text seeks to lay out the fundamental concepts of this huge and continually growing subject area in a clear and comprehensive manner. The Tenth Edition contains new information that highlights various technological updates of recent years, providing readers with highly relevant and current information. Sommerville's experience in system dependability and systems engineering guides the text through a traditional plan-based approach that incorporates some novel agile methods. The text strives to teach the innovators of tomorrow how to create software that will make our world a better, safer, and more advanced place to live.

  5. Leveraging Open Source Software to Create Technical Animations of Scientific Data

    National Research Council Canada - National Science Library

    Vines, John M

    2006-01-01

    .... Army Research Laboratory spends tens of thousands of dollars annually for software licenses for packages such as Maya, Houdini, and 3D Studio Max, while in many instances, an open source package...

  6. Lithium niobate packaging challenges

    International Nuclear Information System (INIS)

    Murphy, E.J.; Holmes, R.J.; Jander, R.B.; Schelling, A.W.

    1988-01-01

    The use of lithium niobate integrated optic devices outside of the research laboratory is predicated on the development of a sound packaging method. The authors present a discussion of the many issues that face the development of a viable, robust packaging technology. The authors emphasize the interaction of lithium niobate's physical properties with available packaging materials and technologies. The broad range of properties (i.e. electro-optic, piezo-electric, pyro-electric, photorefractive...) that make lithium niobate an interesting material in many device applications also make it a packaging challenge. The package design, materials and packaging technologies must isolate the device from the environment so that lithium niobate's properties do not adversely affect the device performance

  7. Packaged die heater

    Science.gov (United States)

    Spielberger, Richard; Ohme, Bruce Walker; Jensen, Ronald J.

    2011-06-21

    A heater for heating packaged die for burn-in and heat testing is described. The heater may be a ceramic-type heater with a metal filament. The heater may be incorporated into the integrated circuit package as an additional ceramic layer of the package, or may be an external heater placed in contact with the package to heat the die. Many different types of integrated circuit packages may be accommodated. The method provides increased energy efficiency for heating the die while reducing temperature stresses on testing equipment. The method allows the use of multiple heaters to heat die to different temperatures. Faulty die may be heated to weaken die attach material to facilitate removal of the die. The heater filament or a separate temperature thermistor located in the package may be used to accurately measure die temperature.

  8. Packaging for Sustainability

    CERN Document Server

    Lewis, Helen; Fitzpatrick, Leanne

    2012-01-01

    The packaging industry is under pressure from regulators, customers and other stakeholders to improve packaging’s sustainability by reducing its environmental and societal impacts. This is a considerable challenge because of the complex interactions between products and their packaging, and the many roles that packaging plays in the supply chain. Packaging for Sustainability is a concise and readable handbook for practitioners who are trying to implement sustainability strategies for packaging. Industry case studies are used throughout the book to illustrate possible applications and scenarios. Packaging for Sustainability draws on the expertise of researchers and industry practitioners to provide information on business benefits, environmental issues and priorities, environmental evaluation tools, design for environment, marketing strategies, and challenges for the future.

  9. Antimicrobial food packaging: potential and pitfalls

    Science.gov (United States)

    Malhotra, Bhanu; Keshwani, Anu; Kharkwal, Harsha

    2015-01-01

    Nowadays food preservation, quality maintenance, and safety are major growing concerns of the food industry. It is evident that over time consumers’ demand for natural and safe food products with stringent regulations to prevent food-borne infectious diseases. Antimicrobial packaging which is thought to be a subset of active packaging and controlled release packaging is one such promising technology which effectively impregnates the antimicrobial into the food packaging film material and subsequently delivers it over the stipulated period of time to kill the pathogenic microorganisms affecting food products thereby increasing the shelf life to severe folds. This paper presents a picture of the recent research on antimicrobial agents that are aimed at enhancing and improving food quality and safety by reduction of pathogen growth and extension of shelf life, in a form of a comprehensive review. Examination of the available antimicrobial packaging technologies is also presented along with their significant impact on food safety. This article entails various antimicrobial agents for commercial applications, as well as the difference between the use of antimicrobials under laboratory scale and real time applications. Development of resistance amongst microorganisms is considered as a future implication of antimicrobials with an aim to come up with actual efficacies in extension of shelf life as well as reduction in bacterial growth through the upcoming and promising use of antimicrobials in food packaging for the forthcoming research down the line. PMID:26136740

  10. A Software Reuse Approach and Its Effect On Software Quality, An Empirical Study for The Software Industry

    OpenAIRE

    Mateen, Ahmed; Kausar, Samina; Sattar, Ahsan Raza

    2017-01-01

    Software reusability has become much interesting because of increased quality and reduce cost. A good process of software reuse leads to enhance the reliability, productivity, quality and the reduction of time and cost. Current reuse techniques focuses on the reuse of software artifact which grounded on anticipated functionality whereas, the non-functional (quality) aspect are also important. So, Software reusability used here to expand quality and productivity of software. It improves overal...

  11. GET_PHYLOMARKERS, a Software Package to Select Optimal Orthologous Clusters for Phylogenomics and Inferring Pan-Genome Phylogenies, Used for a Critical Geno-Taxonomic Revision of the Genus Stenotrophomonas

    Directory of Open Access Journals (Sweden)

    Pablo Vinuesa

    2018-05-01

    Full Text Available The massive accumulation of genome-sequences in public databases promoted the proliferation of genome-level phylogenetic analyses in many areas of biological research. However, due to diverse evolutionary and genetic processes, many loci have undesirable properties for phylogenetic reconstruction. These, if undetected, can result in erroneous or biased estimates, particularly when estimating species trees from concatenated datasets. To deal with these problems, we developed GET_PHYLOMARKERS, a pipeline designed to identify high-quality markers to estimate robust genome phylogenies from the orthologous clusters, or the pan-genome matrix (PGM, computed by GET_HOMOLOGUES. In the first context, a set of sequential filters are applied to exclude recombinant alignments and those producing anomalous or poorly resolved trees. Multiple sequence alignments and maximum likelihood (ML phylogenies are computed in parallel on multi-core computers. A ML species tree is estimated from the concatenated set of top-ranking alignments at the DNA or protein levels, using either FastTree or IQ-TREE (IQT. The latter is used by default due to its superior performance revealed in an extensive benchmark analysis. In addition, parsimony and ML phylogenies can be estimated from the PGM. We demonstrate the practical utility of the software by analyzing 170 Stenotrophomonas genome sequences available in RefSeq and 10 new complete genomes of Mexican environmental S. maltophilia complex (Smc isolates reported herein. A combination of core-genome and PGM analyses was used to revise the molecular systematics of the genus. An unsupervised learning approach that uses a goodness of clustering statistic identified 20 groups within the Smc at a core-genome average nucleotide identity (cgANIb of 95.9% that are perfectly consistent with strongly supported clades on the core- and pan-genome trees. In addition, we identified 16 misclassified RefSeq genome sequences, 14 of them labeled as

  12. GET_PHYLOMARKERS, a Software Package to Select Optimal Orthologous Clusters for Phylogenomics and Inferring Pan-Genome Phylogenies, Used for a Critical Geno-Taxonomic Revision of the Genus Stenotrophomonas.

    Science.gov (United States)

    Vinuesa, Pablo; Ochoa-Sánchez, Luz E; Contreras-Moreira, Bruno

    2018-01-01

    The massive accumulation of genome-sequences in public databases promoted the proliferation of genome-level phylogenetic analyses in many areas of biological research. However, due to diverse evolutionary and genetic processes, many loci have undesirable properties for phylogenetic reconstruction. These, if undetected, can result in erroneous or biased estimates, particularly when estimating species trees from concatenated datasets. To deal with these problems, we developed GET_PHYLOMARKERS, a pipeline designed to identify high-quality markers to estimate robust genome phylogenies from the orthologous clusters, or the pan-genome matrix (PGM), computed by GET_HOMOLOGUES. In the first context, a set of sequential filters are applied to exclude recombinant alignments and those producing anomalous or poorly resolved trees. Multiple sequence alignments and maximum likelihood (ML) phylogenies are computed in parallel on multi-core computers. A ML species tree is estimated from the concatenated set of top-ranking alignments at the DNA or protein levels, using either FastTree or IQ-TREE (IQT). The latter is used by default due to its superior performance revealed in an extensive benchmark analysis. In addition, parsimony and ML phylogenies can be estimated from the PGM. We demonstrate the practical utility of the software by analyzing 170 Stenotrophomonas genome sequences available in RefSeq and 10 new complete genomes of Mexican environmental S. maltophilia complex (Smc) isolates reported herein. A combination of core-genome and PGM analyses was used to revise the molecular systematics of the genus. An unsupervised learning approach that uses a goodness of clustering statistic identified 20 groups within the Smc at a core-genome average nucleotide identity (cgANIb) of 95.9% that are perfectly consistent with strongly supported clades on the core- and pan-genome trees. In addition, we identified 16 misclassified RefSeq genome sequences, 14 of them labeled as S. maltophilia

  13. User friendly packaging

    DEFF Research Database (Denmark)

    Geert Jensen, Birgitte

    2010-01-01

    Most consumers have experienced occasional problems with opening packaging. Tomato sauce from the tinned mackerel splattered all over the kitchen counter, the unrelenting pickle jar lid, and the package of sliced ham that cannot be opened without a knife or a pair of scissors. The research project...... “User-friendly Packaging” aims to create a platform for developing more user-friendly packaging. One intended outcome of the project is a guideline that industry can use in development efforts. The project also points the way for more extended collaboration between companies and design researchers. How...... can design research help industry in packaging innovation?...

  14. The ZOOM minimization package

    International Nuclear Information System (INIS)

    Fischler, Mark S.; Sachs, D.

    2004-01-01

    A new object-oriented Minimization package is available for distribution in the same manner as CLHEP. This package, designed for use in HEP applications, has all the capabilities of Minuit, but is a re-write from scratch, adhering to modern C++ design principles. A primary goal of this package is extensibility in several directions, so that its capabilities can be kept fresh with as little maintenance effort as possible. This package is distinguished by the priority that was assigned to C++ design issues, and the focus on producing an extensible system that will resist becoming obsolete

  15. Plasma physics plotting package

    International Nuclear Information System (INIS)

    Hyman, D.H.

    1981-02-01

    We describe a package of plotting routines that do up to six two- or three-dimensional plots on a frame with minimal loss of resolution. The package now runs on a PDP-10 with PLOT-10 TCS primitives and on a Control Data Corporation-7600 and a Cray-1 with TV80LIB primitives on the National Magnetic Fusion Energy Computer Center network. The package is portable to other graphics systems because only the primitive plot calls are used from the underlying system's graphics package

  16. Active food packaging technologies.

    Science.gov (United States)

    Ozdemir, Murat; Floros, John D

    2004-01-01

    Active packaging technologies offer new opportunities for the food industry, in the preservation of foods. Important active packaging systems currently known to date, including oxygen scavengers, carbon dioxide emitters/absorbers, moisture absorbers, ethylene absorbers, ethanol emitters, flavor releasing/absorbing systems, time-temperature indicators, and antimicrobial containing films, are reviewed. The principle of operation of each active system is briefly explained. Recent technological advances in active packaging are discussed, and food related applications are presented. The effects of active packaging systems on food quality and safety are cited.

  17. Software requirements

    CERN Document Server

    Wiegers, Karl E

    2003-01-01

    Without formal, verifiable software requirements-and an effective system for managing them-the programs that developers think they've agreed to build often will not be the same products their customers are expecting. In SOFTWARE REQUIREMENTS, Second Edition, requirements engineering authority Karl Wiegers amplifies the best practices presented in his original award-winning text?now a mainstay for anyone participating in the software development process. In this book, you'll discover effective techniques for managing the requirements engineering process all the way through the development cy

  18. Software Reviews.

    Science.gov (United States)

    Davis, Shelly J., Ed.; Knaupp, Jon, Ed.

    1984-01-01

    Reviewed is computer software on: (1) classification of living things, a tutorial program for grades 5-10; and (2) polynomial practice using tiles, a drill-and-practice program for algebra students. (MNS)

  19. Software Reviews.

    Science.gov (United States)

    Miller, Anne, Ed.; Radziemski, Cathy, Ed.

    1988-01-01

    Three pieces of computer software are described and reviewed: HyperCard, to build and use varied applications; Iggy's Gnees, for problem solving with shapes in grades kindergarten-two; and Algebra Shop, for practicing skills and problem solving. (MNS)

  20. Customer configuration updating in a software supply network

    NARCIS (Netherlands)

    Jansen, S.R.L.

    2007-01-01

    Product software development is the activity of development, modification, reuse, re-engineering, maintenance, or any other activities that result in packaged configurations of software components or software-based services that are released for and traded in a specific market \\cite{XuBrinkkemper}.

  1. The Value of Open Source Software Tools in Qualitative Research

    Science.gov (United States)

    Greenberg, Gary

    2011-01-01

    In an era of global networks, researchers using qualitative methods must consider the impact of any software they use on the sharing of data and findings. In this essay, I identify researchers' main areas of concern regarding the use of qualitative software packages for research. I then examine how open source software tools, wherein the publisher…

  2. TopView - ATLAS top physics analysis package

    CERN Document Server

    Shibata, A

    2007-01-01

    TopView is a common analysis package which is widely used in the ATLAS top physics working group. The package is fully based on the official ATLAS software Athena and EventView and playing a central role in the collaborative analysis model. It is a functional package which accounts for a broad range issues in implementing physics analysis. As well as being a modular framework suitable as a common workplace for collaborators, TopView implements numerous analysis tools including a complete top-antitop reconstruction and single top reconstruction. The package is currently used to produce common ntuple from Monte Carlo production and future use cases are under rapid development. In this paper, the design and ideas behind TopView and the performance of the analyses implemented in the package are presented with detailed documentation of the contents and instruction for using the package.

  3. Craniux: A LabVIEW-Based Modular Software Framework for Brain-Machine Interface Research

    Science.gov (United States)

    2011-01-01

    open-source BMI software solu- tions are currently available, we feel that the Craniux software package fills a specific need in the realm of BMI...data, such as cortical source imaging using EEG or MEG recordings. It is with these characteristics in mind that we feel the Craniux software package...S. Adee, “Dean Kamen’s ‘luke arm’ prosthesis readies for clinical trials,” IEEE Spectrum, February 2008, http://spectrum .ieee.org/biomedical

  4. Fostering successful scientific software communities

    Science.gov (United States)

    Bangerth, W.; Heister, T.; Hwang, L.; Kellogg, L. H.

    2016-12-01

    Developing sustainable open source software packages for the sciences appears at first to be primarily a technical challenge: How can one create stable and robust algorithms, appropriate software designs, sufficient documentation, quality assurance strategies such as continuous integration and test suites, or backward compatibility approaches that yield high-quality software usable not only by the authors, but also the broader community of scientists? However, our experience from almost two decades of leading the development of the deal.II software library (http://www.dealii.org, a widely-used finite element package) and the ASPECT code (http://aspect.dealii.org, used to simulate convection in the Earth's mantle) has taught us that technical aspects are not the most difficult ones in scientific open source software. Rather, it is the social challenge of building and maintaining a community of users and developers interested in answering questions on user forums, contributing code, and jointly finding solutions to common technical and non-technical challenges. These problems are posed in an environment where project leaders typically have no resources to reward the majority of contributors, where very few people are specifically paid for the work they do on the project, and with frequent turnover of contributors as project members rotate into and out of jobs. In particular, much software work is done by graduate students who may become fluent enough in a software only a year or two before they leave academia. We will discuss strategies we have found do and do not work in maintaining and growing communities around the scientific software projects we lead. Specifically, we will discuss the management style necessary to keep contributors engaged, ways to give credit where credit is due, and structuring documentation to decrease reliance on forums and thereby allow user communities to grow without straining those who answer questions.

  5. Eprints Institutional Repository Software: A Review

    Directory of Open Access Journals (Sweden)

    Mike R. Beazley

    2011-01-01

    Full Text Available Setting up an institutional repository (IR can be a daunting task. There are many software packages out there, some commercial, some open source, all of which offer different features and functionality. This article will provide some thoughts about one of these software packages: Eprints. Eprints was one of the first IR software packages to appear and has been available for 10 years. It is under continual development by its creators at the University of Southampton and the current version is v3.2.3. Eprints is open-source, meaning that anyone can download and make use of the software for free and the software can be modified however the user likes. This presents clear advantages for institutions will smaller budgets and also for institutions that have programmers on staff. Eprints requires some additional software to run: Linux, Apache, MySQL, and Perl. This software is all open-source and already present on the servers of many institutions. There is now a version of Eprints that will run on Windows servers as well, which will make the adoption of Eprints even easier for some. In brief, Eprints is an excellent choice for any institution looking to get an IR up and running quickly and easily. Installation is straightforward as is the initial configuration. Once the IR is up and running, users may upload documents and provide the necessary metadata for the records by filling out a simple web form. Embargoes on published documents are handled elegantly by the software, and the software links to the SHERPA/RoMEO database so authors can easily verify their rights regarding IR submissions. Eprints has some drawbacks, which will be discussed later in the review, but on the whole it is easy to recommend to anyone looking to start an IR. However, It is less clear that an institution with an existing IR based on another software package should migrate to Eprints.

  6. Containment and surveillance for software

    International Nuclear Information System (INIS)

    Andress, J.C.; Adams, G.N.; Cotton, J.H.

    1993-07-01

    Some operators and state authorities are offering their computer systems, both hardware and software, to be used for safeguards purposes by the International Atomic Energy Agency. Therefore a need exists to develop a method of authenticating the data produced by a computer program before it can be used by the Agency. As part of a complete Computer Systems Authentication (COMSAT) package, a method of software containment and surveillance has been developed to compliment existing software authentication techniques. The package is applicable to both operator and Agency provided systems. A program to demonstrate the principles has been written. With this facility, the Agency will be able to leave unattended software in the field, either to be used by the operator to generate data for inspection on their own computer, or to save an inspector having to re-install inspection-specific software on an Agency computer, in the knowledge that the operation of the protected computer is being continuously monitored. If adopted, either of these uses will enable the Agency to reduce their costs. (Author)

  7. CYPROS - Cybernetic Program Packages

    Directory of Open Access Journals (Sweden)

    Arne Tyssø

    1980-10-01

    Full Text Available CYPROS is an interactive program system consisting of a number of special purpose packages for simulation, identification, parameter estimation and control system design. The programming language is standard FORTRAN IV and the system is implemented on a medium size computer system (Nord-10. The system is interactive and program control is obtained by the use of numeric terminals. Output is rapidly examined by extensive use of video colour graphics. The subroutines included in the packages are designed and documented according to standardization rules given by the SCL (Scandinavian Control Library organization. This simplifies the exchange of subroutines throughout the SCL system. Also, this makes the packages attractive for implementation by industrial users. In the simulation package, different integration methods are available and it can be easily used for off-line, as well as real time, simulation problems. The identification package consists of programs for single-input/single-output and multivariablc problems. Both transfer function models and state space models can be handled. Optimal test signals can be designed. The control package consists of programs based on multivariable time domain and frequency domain methods for analysis and design. In addition, there is a package for matrix and time series manipulation. CYPROS has been applied successfully to industrial problems of various kinds, and parts of the system have already been implemented on different computers in industry. This paper will, in some detail, describe the use and the contents of the packages and some examples of application will be discussed.

  8. User friendly packaging

    DEFF Research Database (Denmark)

    Geert Jensen, Birgitte

    2010-01-01

    Most consumers have experienced occasional problems with opening packaging. Tomato sauce from the tinned mackerel splattered all over the kitchen counter, the unrelenting pickle jar lid, and the package of sliced ham that cannot be opened without a knife or a pair of scissors. The research project...

  9. NRF TRIGA packaging

    International Nuclear Information System (INIS)

    Clements, M.D.

    1995-11-01

    Training Reactor Isotopes, General Atomics (TRIGA reg-sign) Reactors are in use at four US Department of Energy (DOE) complex facilities and at least 23 university, commercial, or government facilities. The development of the Neutron Radiography Facility (NRF) TRIGA packaging system began in October 1993. The Hanford Site NRF is being shut down and requires an operationally user-friendly transportation and storage packaging system for removal of the TRIGA fuel elements. The NRF TRIGA packaging system is designed to remotely remove the fuel from the reactor and transport the fuel to interim storage (up to 50 years) on the Hanford Site. The packaging system consists of a cask and an overpack. The overpack is used only for transport and is not necessary for storage. Based upon the cask's small size and light weight, small TRIGA reactors will find it versatile for numerous refueling and fuel storage needs. The NRF TRIGA packaging design also provides the basis for developing a certifiable and economical packaging system for other TRIGA reactor facilities. The small size of the NRF TRIGA cask also accommodates placing the cask into a larger certified packaging for offsite transport. The Westinghouse Hanford Company NRF TRIGA packaging, as described herein can serve other DOE sites for their onsite use, and the design can be adapted to serve university reactor facilities, handling a variety of fuel payloads

  10. WASTE PACKAGE TRANSPORTER DESIGN

    International Nuclear Information System (INIS)

    Weddle, D.C.; Novotny, R.; Cron, J.

    1998-01-01

    The purpose of this Design Analysis is to develop preliminary design of the waste package transporter used for waste package (WP) transport and related functions in the subsurface repository. This analysis refines the conceptual design that was started in Phase I of the Viability Assessment. This analysis supports the development of a reliable emplacement concept and a retrieval concept for license application design. The scope of this analysis includes the following activities: (1) Assess features of the transporter design and evaluate alternative design solutions for mechanical components. (2) Develop mechanical equipment details for the transporter. (3) Prepare a preliminary structural evaluation for the transporter. (4) Identify and recommend the equipment design for waste package transport and related functions. (5) Investigate transport equipment interface tolerances. This analysis supports the development of the waste package transporter for the transport, emplacement, and retrieval of packaged radioactive waste forms in the subsurface repository. Once the waste containers are closed and accepted, the packaged radioactive waste forms are termed waste packages (WP). This terminology was finalized as this analysis neared completion; therefore, the term disposal container is used in several references (i.e., the System Description Document (SDD)) (Ref. 5.6). In this analysis and the applicable reference documents, the term ''disposal container'' is synonymous with ''waste package''

  11. WASTE PACKAGE TRANSPORTER DESIGN

    Energy Technology Data Exchange (ETDEWEB)

    D.C. Weddle; R. Novotny; J. Cron

    1998-09-23

    The purpose of this Design Analysis is to develop preliminary design of the waste package transporter used for waste package (WP) transport and related functions in the subsurface repository. This analysis refines the conceptual design that was started in Phase I of the Viability Assessment. This analysis supports the development of a reliable emplacement concept and a retrieval concept for license application design. The scope of this analysis includes the following activities: (1) Assess features of the transporter design and evaluate alternative design solutions for mechanical components. (2) Develop mechanical equipment details for the transporter. (3) Prepare a preliminary structural evaluation for the transporter. (4) Identify and recommend the equipment design for waste package transport and related functions. (5) Investigate transport equipment interface tolerances. This analysis supports the development of the waste package transporter for the transport, emplacement, and retrieval of packaged radioactive waste forms in the subsurface repository. Once the waste containers are closed and accepted, the packaged radioactive waste forms are termed waste packages (WP). This terminology was finalized as this analysis neared completion; therefore, the term disposal container is used in several references (i.e., the System Description Document (SDD)) (Ref. 5.6). In this analysis and the applicable reference documents, the term ''disposal container'' is synonymous with ''waste package''.

  12. The BINSYN Program Package

    Directory of Open Access Journals (Sweden)

    Albert P. Linnell

    2012-06-01

    Full Text Available The BINSYN program package, recently expanded to calculate synthetic spectra of cataclysmic variables, is being further extended to include synthetic photometry of ordinary binary stars in addition to binary stars with optically thick accretion disks. The package includes a capability for differentials correction optimization of eclipsing binary systems using synthetic photometry.

  13. The LCDROOT Analysis Package

    International Nuclear Information System (INIS)

    Abe, Toshinori

    2001-01-01

    The North American Linear Collider Detector group has developed simulation and analysis program packages. LCDROOT is one of the packages, and is based on ROOT and the C++ programing language to maximally benefit from object oriented programming techniques. LCDROOT is constantly improved and now has a new topological vertex finder, ZVTOP3. In this proceeding, the features of the LCDROOT simulation are briefly described

  14. Grooming. Learning Activity Package.

    Science.gov (United States)

    Stark, Pamela

    This learning activity package on grooming for health workers is one of a series of 12 titles developed for use in health occupations education programs. Materials in the package include objectives, a list of materials needed, information sheets, reviews (self evaluations) of portions of the content, and answers to reviews. These topics are…

  15. QUEST. Qualification and testing of shock-absorbing structures and materials for the optimization/reduction of loads on packages for the disposal of radioactive residues from decommissioning and removal; QUEST. Qualifikation und Erprobung von stossdaempfenden Strukturen und Materialien zur Optimierung/Reduzierung der Beanspruchung von Verpackungen zur Entsorgung radioaktiver Reststoffe aus Stilllegung und Rueckbau.

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-03-15

    The safe enclosure of radioactive residues from decommissioning of nuclear facilities has to be guaranteed using appropriated packaging. The container design has to consider accidental drops from different heights and on different ground conditions. For energy absorbing pine wood and polyurethane foams are possible, damping concrete for the underground is discussed. Optimization and reduction of mechanical loads on the containers a demonstration concept is planned. The project QUEST is aimed to study the materials behavior of pine wood, polyurethane foam and damping concrete under hypothetical boundary conditions of a drop accident. Appropriate numerical modeling had to be developed.

  16. Packaged low-level waste verification system

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, K.; Winberg, M.R.; McIsaac, C.V. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1995-12-31

    The Department of Energy through the National Low-Level Waste Management Program and WMG Inc. have entered into a joint development effort to design, build, and demonstrate the Packaged Low-Level Waste Verification System. Currently, states and low-level radioactive waste disposal site operators have no method to independently verify the radionuclide content of packaged low-level waste that arrives at disposal sites for disposition. At this time, the disposal site relies on the low-level waste generator shipping manifests and accompanying records to ensure that low-level waste received meets the site`s waste acceptance criteria. The subject invention provides the equipment, software, and methods to enable the independent verification of low-level waste shipping records to ensure that the site`s waste acceptance criteria are being met. The objective of the prototype system is to demonstrate a mobile system capable of independently verifying the content of packaged low-level waste.

  17. Waste package performance analysis

    International Nuclear Information System (INIS)

    Lester, D.H.; Stula, R.T.; Kirstein, B.E.

    1982-01-01

    A performance assessment model for multiple barrier packages containing unreprocessed spent fuel has been applied to several package designs. The resulting preliminary assessments were intended for use in making decisions about package development programs. A computer model called BARIER estimates the package life and subsequent rate of release of selected nuclides. The model accounts for temperature, pressure (and resulting stresses), bulk and localized corrosion, and nuclide retardation by the backfill after water intrusion into the waste form. The assessment model assumes a post-closure, flooded, geologic repository. Calculations indicated that, within the bounds of model assumptions, packages could last for several hundred years. Intact backfills of appropriate design may be capable of nuclide release delay times on the order of 10 7 yr for uranium, plutonium, and americium. 8 references, 6 figures, 9 tables

  18. RH Packaging Operations Manual

    International Nuclear Information System (INIS)

    Washington TRU Solutions LLC

    2003-01-01

    This procedure provides operating instructions for the RH-TRU 72-B Road Cask, Waste Shipping Package. In this document, ''Packaging'' refers to the assembly of components necessary to ensure compliance with the packaging requirements (not loaded with a payload). ''Package'' refers to a Type B packaging that, with its radioactive contents, is designed to retain the integrity of its containment and shielding when subject to the normal conditions of transport and hypothetical accident test conditions set forth in 10 CFR Part 71. Loading of the RH 72-B cask can be done two ways, on the RH cask trailer in the vertical position or by removing the cask from the trailer and loading it in a facility designed for remote-handling (RH). Before loading the 72-B cask, loading procedures and changes to the loading procedures for the 72-B cask must be sent to CBFO at sitedocuments at wipp.ws for approval

  19. Advanced flip chip packaging

    CERN Document Server

    Lai, Yi-Shao; Wong, CP

    2013-01-01

    Advanced Flip Chip Packaging presents past, present and future advances and trends in areas such as substrate technology, material development, and assembly processes. Flip chip packaging is now in widespread use in computing, communications, consumer and automotive electronics, and the demand for flip chip technology is continuing to grow in order to meet the need for products that offer better performance, are smaller, and are environmentally sustainable. This book also: Offers broad-ranging chapters with a focus on IC-package-system integration Provides viewpoints from leading industry executives and experts Details state-of-the-art achievements in process technologies and scientific research Presents a clear development history and touches on trends in the industry while also discussing up-to-date technology information Advanced Flip Chip Packaging is an ideal book for engineers, researchers, and graduate students interested in the field of flip chip packaging.

  20. 7. annual software survey 2009

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2009-07-15

    This article presented a guide to new software applications designed to facilitate petroleum exploration, drilling and production activities. Oil and gas producers can use the products for a range of functions, including reservoir characterization and accounting. In addition to a description of the software application, this article listed the name of software providers and the new features available in each product. The featured software developed by Calgary-based providers included: OpenInvoice software developed by DO2 Technologies Inc; oil and gas solutions by Energy Navigator; WellSpring planning system by Enersight; Entero MOSAIC and Entero ONE software packages by Entero Corporation; Emission Manager by Envirosoft Corporation; ResSurveil, ResBalance and ResAssist by Epic Consulting Services Ltd.; OMNI 3D, VISTA 2D/3D seismic software by Gedco; geoSCOUT, petroCUBE and gDC by GeoLOGIC Systems Ltd.; IHS AccuMap and PETRA by IHS; WELLFLO, PIPEFLO and FORGAS wellbore solutions by Neotec; AFENexus, FANexus, GeoNexus, JVNexus, PANexus software by Pandell Technology Corporation; Oil and gas solutions by the Risk Advisory division of SAS; Petrel, ECLIPSE, Avocet, Osprey and Merak by Schlumberger Information Solutions; esi.manage and esi.executive by 3esi; and STABView, ROCKSBank by Weatherford Advanced Geotechnology. The featured software developed by Texas-based providers included the HTRI Xchanger Suite by Heat Transfer Research Inc.; the RFID-based asset tracking system by Merrick Systems; oil and gas solutions by Neuralog Inc.; geoscience data programs by OpenSpirit; and oil and gas solutions by Seismic Micro-Technology Inc. The featured software developed by Vancouver-based providers included the oil and gas solutions by Sustainet Software Solutions Inc.