  1. Evaluation of image quality and patient safety: paired inspiratory and expiratory MDCT assessment of tracheobronchomalacia in paediatric patients under general anaesthesia with breath-hold technique

    International Nuclear Information System (INIS)

    Lee, Edward Y.; Bastos, Maria d' Almeida; Stark, Cynthia; Carrier, Maureen; Zurakowski, David; Mason, Keira P.

    2012-01-01

    The purpose of our investigation was to evaluate image quality and patient safety in infants and young children who required general anaesthesia with breath-hold technique for paired inspiratory and expiratory multidetector CT (MDCT) assessment of tracheobronchomalacia (TBM). Our hospital's institutional review board approved the review of radiological and clinical data of a consecutive series of 20 paediatric patients who underwent MDCT under general anaesthesia with breath-hold technique for evaluation of TBM from May 2006 to December 2008. For each MDCT study, two fellowship-trained paediatric radiologists reviewed the inspiratory and expiratory MDCT images in an independent, randomised and blinded fashion for the presence of motion artefact at three anatomic levels (upper, middle and lower central airways). The clinical history and anaesthesia outcome, including the occurrence of any adverse events during or following the MDCT examinations until discharge, were also reviewed and recorded. The study population consisted of 20 infants and young children (13 boys/seven girls, mean age 1.7 ± 1.4 years, age range 11 days to 4 years). The imaging quality of all 20 MDCT studies was diagnostic with no motion artefact in 16 studies (80%) and minimal motion artefact in the remaining four studies (20%). Minor adverse events occurred in three patients (15%) that included one patient (5%) with a brief (<60 s) oxygen desaturation during MDCT study, which resolved with oxygen, and two patients (5%) with either a brief (<60 s) oxygen desaturation (n = 1, 5%) or cough (n = 1, 5%) during recovery period, which were completely resolved with oxygen and dexamethasone, respectively. Diagnostic quality paired inspiratory and expiratory MDCT imaging with breath-hold technique can be safely performed in infants and young children under general anaesthesia for evaluation of TBM.

  2. Multi-detector CT evaluation in patients suspected of tracheobronchomalacia: Comparison of end-expiratory with dynamic expiratory volumetric acquisitions

    Energy Technology Data Exchange (ETDEWEB)

    Ferretti, Gilbert R. [Department of Radiology (France)], E-mail: gferretti@chu-grenoble.fr; Jankowski, Adrien [Department of Radiology (France)], E-mail: ajankowski@chu-grenoble.fr; Perrin, Marie Amelie [Department of Radiology (France)], E-mail: maperrin@chu-grenoble.fr; Chouri, Nathalie [Department of Respiratory Diseases (France)], E-mail: nchouri@chu-grenoble.fr; Arnol, Nathalie [Sleep Laboratory and EFCR, University Hospital, Grenoble (France); HP2 Laboratory, INSERM ERI 0017 (Hypoxia: Pathophysiology), Joseph Fourier University, Grenoble (France)], E-mail: narnold@chu-grenoble.fr; Aubaud, Laurent [Department of Radiology (France)], E-mail: laubaud@chu-grenoble.fr; Pepin, Jean-Louis [Sleep Laboratory and EFCR, University Hospital, Grenoble (France); HP2 Laboratory, INSERM ERI 0017 (Hypoxia: Pathophysiology), Joseph Fourier University, Grenoble (France)], E-mail: jlpepin@chu-grenoble.fr

    2008-11-15

    Purpose: The aim of this study was to compare dynamic expiratory imaging and end-expiratory imaging using multi-detector CT (MDCT) of the central airways in patients suspected of tracheobronchomalacia (TBM). Methods: This study had local ethical committee approval. Seventy patients suspected of TBM were prospectively included. All patients underwent evaluation of central airways by three different low-dose MDCT acquisitions: end inspiration, end expiration, and dynamic expiration. Degree of airway collapse was measured by calculating the percentage change in the area and diameter of the airways between inspiratory and the two expiratory techniques at three levels of the trachea and in the sagittal diameter of the right and left main bronchi. Three threshold levels of percentage reduction in diameter or area (30%, 50%, and 70%) for defining TBM were evaluated. Results: In the entire population, the mean percentage of airway collapse was significantly greater with dynamic expiratory imaging than with the end-expiratory imaging at three different levels: lower thoracic trachea (26% vs. 16.6%, p < 0.009), right (25.2% vs. 14%, p < 0.01) and left main (24.7% vs. 13.3%, p < 0.01) bronchus. Whatever the threshold value for defining TBM, dynamic expiratory imaging always resulted in diagnosing TBM in more patients than end-expiratory imaging. Conclusions: Dynamic expiratory imaging shows a significantly greater degree and a significantly greater extent of airway collapse than standard end-expiratory imaging in patients suspected of TBM. Further evaluation of the clinical relevance of such findings is warranted.

  3. Radiation dose reduction to the male gonads during MDCT: the effectiveness of a lead shield.

    Science.gov (United States)

    Hohl, Christian; Mahnken, Andreas H; Klotz, Ernst; Das, Marco; Stargardt, Achim; Mühlenbruch, Georg; Schmidt, Thorsten; Günther, Rolf W; Wildberger, Joachim E

    2005-01-01

    Our study was designed to quantify the effect of a standard gonad shield on the testicular radiation exposure due to scatter during routine abdominopelvic MDCT. Routine abdominopelvic MDCT was performed in 34 patients with gonadal lead shielding and 32 patients without this shielding; the testes were not exposed to the direct beam during the examination. We estimated the testicular dose administered with thermoluminescent dosimetry, taking into account each patient's body weight and body mass index (BMI). With a 1-mm lead shield, the mean testicular dose was reduced from 2.40 to 0.32 mSv, a reduction of 87%. The difference was found to be statistically significant (p Shielding the male gonads reduces the testicular radiation dose during abdominopelvic MDCT significantly and can be recommended for routine use.

  4. Low dose MDCT of the wrist-An ex vivo approach

    International Nuclear Information System (INIS)

    Bolte, H.; Sattler, E.-M.; Jahnke, T.; Roeger, I.; Biederer, J.; Jochens, A.; Dischinger, J.; Schuenke, M.; Sedlmair, M.; Heller, M.

    2011-01-01

    The primary objective of this study was to evaluate, if in multidetector computed tomography (MDCT) of the wrist a good image quality can be maintained while radiation dose is substantially reduced. In a second approach one solely parameter change that allows for the best trade-off between dose reduction and image quality should be identified. Twenty wrist specimens were examined with a 16-slice MDCT in different parameter combinations: 120 and 100 kV, 100, 70 and 40 electronic mA s, pitch factor 0.9 and 1.5. Images were reconstructed in four standard planes (slice thickness 1.0 mm, increment 0.5 mm, hard kernel) resulting into a total number of 960 images. Two observers evaluated image quality in a blinded and randomized consensus scheme. Detail quality of corticalis, spongiosa, articular surface and soft tissues was graded according to a four-point scale (1 = excellent, 2 = good, 3 = sufficient, and 4 = poor). The scan protocol with the best trade-off between radiation exposure and image quality had a parameter constellation of 100 kV, 70 electronic mA s (78 effective mA s) and a pitch of 0.9 (DLP 63 mGy cm). This represented a dose reduction of 55%. A solely decrease of voltage lead to a dose reduction of 36% without any loss of image quality. An increase of the pitch factor to 1.5 and a decrease from 70 to 40 mA s caused the most distinct impairment of image quality. In MDCT of the wrist good image quality could be maintained while radiation dose was considerably reduced. A reduction of voltage offers the best result for a solely parameter change.

  5. Incidence of tracheobronchomalacia associated with pulmonary emphysema. Detection with paired inspiratory-expiratory multidetector computed tomography using a low-dose technique

    International Nuclear Information System (INIS)

    Inoue, Masanori; Hasegawa, Ichiro; Nakano, Keiko; Yamaguchi, Kazuhiro; Kuribayashi, Sachio

    2009-01-01

    The purpose of this study was to evaluate the frequency of tracheobronchomalacia (TBM) associated with pulmonary emphysema with paired inspiratory-expiratory multidetector computed tomography (MDCT) using a low-dose technique. This study included 56 consecutive patients (55 men, 1 woman; mean age 68.9 years) with pulmonary emphysema who had undergone paired inspiratory-expiratory CT scanning with a low-dose technique (40 mA). All images were retrospectively examined by two thoracic radiologists in a blinded fashion. The diagnosis of TBM was based on the standard criterion of >50% reduction in the cross-sectional area of the tracheobronchial lumen at the end-expiratory phase. A mild TBM criterion of >30% reduction was also reviewed. All patients underwent pulmonary function tests. The relation between the forced expiratory volume in 1 s (FEV 1.0% ) and TBM was statistically analyzed. Four (7.1%) and eight (14.3%) patients were diagnosed as TBM based on the standard and mild criteria, respectively. In four patients, the percentages of luminal narrowing were 63.4% and 51.2%, respectively for tracheomalacia and 59.2% and 62.0%, respectively, for bronchomalacia. The FEV 1.0% values between patients with and without TBM showed no statistical difference. The incidence of TBM associated with pulmonary emphysema was 7.1% with the standard criterion. It is possible that TBM has been underdiagnosed in a number of patients with pulmonary emphysema. (author)

  6. Evaluation of radiation doses from MDCT-imaging in otolaryngology

    International Nuclear Information System (INIS)

    Yamauchi-Kawaura, C.; Fujii, K.; Aoyama, T.; Yamauchi, M.; Koyama, S.

    2009-01-01

    The purpose of this study was to clarify patient doses in the current otolaryngological multi-detector row computed tomography (MDCT) examinations. Patient doses were measured with an in-phantom dosimetry system which was composed of 48 photodiode dosemeters embedded within an anthropomorphic phantom. Organ and effective doses were evaluated according to the International Commission on Radiological Protection Publication 103. In neck CT, doses for salivary glands and for thyroid were high, 7.6-29.9 and 13.4-60.3 mGy, respectively. In sinus CT, brain and lens doses were high, 7.6-24.6 and 10.6-32.0 mGy, respectively, and in inner ear CT, lens dose was 8.0-35.3 mGy. Effective doses were 1.8-6.6 mSv in neck CT, 0.5-0.9 mSv in sinus CT and 0.3-0.6 mSv in inner ear CT. The present dose data would be used to estimate radiation risks for patients undergoing otolaryngological MDCT examinations. (authors)

  7. Static end-expiratory and dynamic forced expiratory tracheal collapse in COPD

    International Nuclear Information System (INIS)

    O'Donnell, C.R.; Bankier, A.A.; O'Donnell, D.H.; Loring, S.H.; Boiselle, P.M.

    2014-01-01

    Aim: To determine the range of tracheal collapse at end-expiration among chronic obstructive pulmonary disease (COPD) patients and to compare the extent of tracheal collapse between static end-expiratory and dynamic forced-expiratory multidetector-row computed tomography (MDCT). Materials and methods: After institutional review board approval and obtaining informed consent, 67 patients meeting the National Heart, Lung, and Blood Institute (NHLBI)/World Health Organization (WHO) Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria for COPD were sequentially imaged using a 64-detector-row CT machine at end-inspiration, during forced expiration, and at end-expiration. Standardized respiratory coaching and spirometric monitoring were employed. Mean percentage tracheal collapse at end-expiration and forced expiration were compared using correlation analysis, and the power of end-expiratory cross-sectional area to predict excessive forced-expiratory tracheal collapse was computed following construction of receiver operating characteristic (ROC) curves. Results: Mean percentage expiratory collapse among COPD patients was 17 ± 18% at end-expiration compared to 62 ± 16% during forced expiration. Over the observed range of end-expiratory tracheal collapse (approximately 10–50%), the positive predictive value of end-expiratory collapse to predict excessive (≥80%) forced expiratory tracheal collapse was <0.3. Conclusion: COPD patients demonstrate a wide range of end-expiratory tracheal collapse. The magnitude of static end-expiratory tracheal collapse does not predict excessive dynamic expiratory tracheal collapse

  8. Coronary calcium scoring with MDCT: The radiation dose to the breast and the effectiveness of bismuth breast shield

    International Nuclear Information System (INIS)

    Yilmaz, Mehmet Halit; Yasar, Dogan; Albayram, Sait; Adaletli, Ibrahim; Ozer, Harun; Ozbayrak, Mustafa; Mihmanli, Ismail; Akman, Canan

    2007-01-01

    Objective: The purpose of our study was to determine the breast radiation dose during coronary calcium scoring with multidetector computerized tomography (MDCT). We also evaluated the degree of dose reduction by using a bismuth breast shield when performing coronary calcium scoring with MDCT. Materials and methods: The dose reduction achievable by shielding the adult (35 years or older) female breasts was studied in 25 women who underwent coronary calcium scoring with MDCT. All examinations were performed with a 16-MDCT scanner. To compare the shielded versus unshielded breast dose, the examinations were performed with (right breast) and without (left breast) breast shielding in all patients. With this technique the superficial breast doses were calculated. To determine the average glandular breast radiation dose, we imaged an anthropomorphic dosimetric phantom into which calibrated dosimeters were placed to measure the dose to the breast. The phantom was imaged using the same protocol. Radiation doses to the breasts with and without the breast shielding were measured and compared using the Student's t-test. Results: The mean radiation doses with and without the breast shield were 5.71 ± 1.1 mGy versus 9.08 ± 1.5 mGy, respectively. The breast shield provided a 37.12% decrease in radiation dose to the breast with shielding. The difference between the dose received by the breasts with and without bismuth shielding was significant, with a p-value of less than 0.001. Conclusion: The high radiation during MDCT greatly exceeds the recommended doses and should not be underestimated. Bismuth in plane shielding for coronary calcium scoring with MDCT decreased the radiation dose to the breast. We recommend routine use of breast shields in female patients undergoing calcium scoring with MDCT

  9. 256-MDCT for evaluation of urolithiasis: iterative reconstruction allows for a significant reduction of the applied radiation dose while maintaining high subjective and objective image quality

    International Nuclear Information System (INIS)

    Veldhoen, Simon; Laqmani, Azien; Derlin, Thorsten; Karul, Murat; Hammerle, Diego; Adam, Gerhard; Regier, Marc; Buhk, Jan-Hendrick; Sehner, Susanne; Nagel, Hans D.; Chun, Felix

    2014-01-01

    Multidetector CT (MDCT) is the established imaging modality in diagnostics of urolithiasis. The aim of iterative reconstruction (IR) is to allow for a radiation dose reduction while maintaining high image quality. This study evaluates its performance in MDCT for assessment of urolithiasis. Fifty-two patients underwent non-contrast abdominal MDCT. Twenty-six patients were referred to MDCT under suspicion of urolithiasis, and examined using a dose-reduced scan protocol (RDCT). Twenty-six patients, who had undergone standard-dose MDCT, served as reference for radiation dose comparison. RDCT images were reconstructed using an IR system (iDose4™, Philips Healthcare, Cleveland, OH, USA). Objective image noise (OIN) was recorded and five radiologists rated the subjective image quality independently. Radiation parameters were derived from the scan protocols. The CTDIvol could be reduced by 50% to 5.8 mGy (P < 0.0001). The same reduction was achieved for DLP and effective dose to 253 ± 27 mGy*cm (P < 0.0001) and 3.9 ± 0.4 mSv (P < 0.0001). IR led to a reduction of the OIN of up to 61% compared with classic filtered back projection (FBP) (P < 0.0001). The OIN declined with increasing IR levels. RDCT with FBP showed the lowest scores of subjective image quality (2.32 ± 0.04). Mean scores improved with increasing IR levels. iDose6 was rated with the best mean score (3.66 ± 0.04). The evaluated IR-tool and protocol may be applied to achieve a considerable radiation dose reduction in MDCT for diagnostics of urolithiasis while maintaining a confident image quality. Best image quality, suitable for evaluation of the entire abdomen concerning differential diagnoses, was achieved with iDose6.

  10. MDCT assessment of tracheomalacia in symptomatic infants with mediastinal aortic vascular anomalies: preliminary technical experience

    International Nuclear Information System (INIS)

    Lee, Edward Y.; Mason, Keira P.; Zurakowski, David; Waltz, David A.; Ralph, Amy; Riaz, Farhana; Boiselle, Phillip M.

    2008-01-01

    Mediastinal aortic vascular anomalies are relatively common causes of extrinsic central airway narrowing in infants with respiratory symptoms. Surgical correction of mediastinal aortic vascular anomalies alone might not adequately treat airway symptoms if extrinsic narrowing is accompanied by intrinsic tracheomalacia (TM), a condition that escapes detection on routine end-inspiratory imaging. Paired inspiratory-expiratory multidetector CT (MDCT) has the potential to facilitate early diagnosis and timely management of TM in symptomatic infants with mediastinal aortic vascular anomalies. To assess the technical feasibility of paired inspiratory-expiratory MDCT for evaluating TM among symptomatic infants with mediastinal aortic vascular anomalies. The study group consisted of five consecutive symptomatic infants (four male, one female; mean age 4.1 months, age range 2 weeks to 6 months) with mediastinal aortic vascular anomalies who were referred for paired inspiratory-expiratory MDCT during a 22-month period. CT angiography was concurrently performed during the end-inspiration phase of the study. Two pediatric radiologists in consensus reviewed all CT images in a randomized and blinded fashion. The end-inspiration and end-expiration CT images were reviewed for the presence and severity of tracheal narrowing. TM was defined as ≥50% reduction in tracheal cross-sectional luminal area between end-inspiration and end-expiration. The presence of TM was compared to the bronchoscopy results when available (n = 4). Paired inspiratory-expiratory MDCT was technically successful in all five patients. Mediastinal aortic vascular anomalies included a right aortic arch with an aberrant left subclavian artery (n = 2), innominate artery compression (n = 2), and a left aortic arch with an aberrant right subclavian artery (n 1). Three (60%) of the five patients demonstrated focal TM at the level of mediastinal aortic vascular anomalies. The CT results were concordant with the results

  11. Influence of radiation dose and reconstruction algorithm in MDCT assessment of airway wall thickness: A phantom study

    International Nuclear Information System (INIS)

    Gomez-Cardona, Daniel; Nagle, Scott K.; Li, Ke; Chen, Guang-Hong; Robinson, Terry E.

    2015-01-01

    levels. For FBP, the relative bias and the angular standard deviation of the measured WT increased steeply with decreasing radiation dose. Except for the smallest airway, MBIR enabled significant reduction in both the relative bias and angular standard deviation of the WT, particularly at low radiation dose levels; the SSQ was reduced by 50%–96% by using MBIR. The optimal reconstruction algorithm was found to be MBIR for the seven airways being assessed, and the combined use of MBIR and optimal kV–mAs selection resulted in a radiation dose reduction of 37%–83% compared with a reference scan protocol with a dose level of 1 mGy. Conclusions: The quantification accuracy of airway WT is strongly influenced by radiation dose and reconstruction algorithm. The MBIR algorithm potentially allows the desired WT quantification accuracy to be achieved with reduced radiation dose, which may enable a wider clinical use of MDCT for the assessment of airway WT, particularly for younger patients who may be more sensitive to exposures with ionizing radiation

  12. Influence of radiation dose and reconstruction algorithm in MDCT assessment of airway wall thickness: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Cardona, Daniel [Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, 1111 Highland Avenue, Madison, Wisconsin 53705 (United States); Nagle, Scott K. [Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, 1111 Highland Avenue, Madison, Wisconsin 53705 (United States); Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, 600 Highland Avenue, Madison, Wisconsin 53792 (United States); Department of Pediatrics, University of Wisconsin-Madison School of Medicine and Public Health, 600 Highland Avenue, Madison, Wisconsin 53792 (United States); Li, Ke; Chen, Guang-Hong, E-mail: gchen7@wisc.edu [Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, 1111 Highland Avenue, Madison, Wisconsin 53705 (United States); Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, 600 Highland Avenue, Madison, Wisconsin 53792 (United States); Robinson, Terry E. [Department of Pediatrics, Stanford School of Medicine, 770 Welch Road, Palo Alto, California 94304 (United States)

    2015-10-15

    levels. For FBP, the relative bias and the angular standard deviation of the measured WT increased steeply with decreasing radiation dose. Except for the smallest airway, MBIR enabled significant reduction in both the relative bias and angular standard deviation of the WT, particularly at low radiation dose levels; the SSQ was reduced by 50%–96% by using MBIR. The optimal reconstruction algorithm was found to be MBIR for the seven airways being assessed, and the combined use of MBIR and optimal kV–mAs selection resulted in a radiation dose reduction of 37%–83% compared with a reference scan protocol with a dose level of 1 mGy. Conclusions: The quantification accuracy of airway WT is strongly influenced by radiation dose and reconstruction algorithm. The MBIR algorithm potentially allows the desired WT quantification accuracy to be achieved with reduced radiation dose, which may enable a wider clinical use of MDCT for the assessment of airway WT, particularly for younger patients who may be more sensitive to exposures with ionizing radiation.

  13. Nonlinear image blending for dual-energy MDCT of the abdomen: can image quality be preserved if the contrast medium dose is reduced?

    Science.gov (United States)

    Mileto, Achille; Ramirez-Giraldo, Juan Carlos; Marin, Daniele; Alfaro-Cordoba, Marcela; Eusemann, Christian D; Scribano, Emanuele; Blandino, Alfredo; Mazziotti, Silvio; Ascenti, Giorgio

    2014-10-01

    The objective of this study was to compare the image quality of a dual-energy nonlinear image blending technique at reduced load of contrast medium with a simulated 120-kVp linear blending technique at a full dose during portal venous phase MDCT of the abdomen. Forty-five patients (25 men, 20 women; mean age, 65.6 ± 9.7 [SD] years; mean body weight, 74.9 ± 12.4 kg) underwent contrast-enhanced single-phase dual-energy CT of the abdomen by a random assignment to one of three different contrast medium (iomeprol 400) dose injection protocols: 1.3, 1.0, or 0.65 mL/kg of body weight. The contrast-to-noise ratio (CNR) and noise at the portal vein, liver, aorta, and kidney were compared among the different datasets using the ANOVA. Three readers qualitatively assessed all datasets in a blinded and independent fashion. Nonlinear blended images at a 25% reduced dose allowed a significant improvement in CNR (p < 0.05 for all comparisons), compared with simulated 120-kVp linear blended images at a full dose. No statistically significant difference existed in CNR and noise between the nonlinear blended images at a 50% reduced dose and the simulated 120-kVp linear blended images at a full dose. Nonlinear blended images at a 50% reduced dose were considered in all cases to have acceptable image quality. The dual-energy nonlinear image blending technique allows reducing the dose of contrast medium up to 50% during portal venous phase imaging of the abdomen while preserving image quality.

  14. Paediatric multidetector CT optimisation training: a survey of common scanning procedures and the resultant dose reduction associated with paediatric MDCT investigations in Australia

    International Nuclear Information System (INIS)

    Wallace, Anthony; Sibelle, Kimberly; Stanley, Martin; Budd, Ray; Goergen, Stacey; Heggie, John

    2008-01-01

    The growing recognition of the increased risk of stochastic injury to paediatric patients from multidetector CT (MDCT) investigations prompted a survey sponsored by Royal Australian and New Zealand College of Radiology (RANZCR), Austin Health and Monash University to initiate a national paediatric dosimetry review for some of the most common investigations undertaken in MDCT paediatric practice. The survey forms included a data sheet requiring acquisition protocol parameters and a phantom graphic sheet requiring the marking of the inferior and superior acquisition margins. Survey forms were supplied for each of 13 common MDCT acquisitions to be tested. Response data was input into CT-Expo Version 1.5.1., a CT dosimetry calculation engine, to determine dose length product (DLP (mGy.cm)) and effective dose (ED (mSv)). Initial survey data was collected, calculated, blinded and collated into various presentations that were given at a MDCT optimisation seminar in November, 2006. All sites were re-surveyed in May 2007 and doses calculated. Initial survey data showed a range of dose efficiencies spread across the surveyed sites. A measure of the initial spread of DLP values per procedure ranged from a minimum of less than 2 for a head-trauma acquisition (372 - 520 mGy.cm) to 14 for a chest-trauma acquisition (28 - 388 mGy.cm). Results of the 2nd survey strongly indicate that the application of optimisation training to paediatric MDCT scanning can produce significant dose savings by the application of simple dose saving strategies. Many protocols demonstrated dose reductions of greater than 50% with significant reductions in both the maximum and minimum values of calculated DLP and ED. The development of a survey-training-resurvey model of MDCT optimisation has proven to be a successful strategy for paediatric MDCT dose reduction in Australia. (author)

  15. Effect of Low-Dose MDCT and Iterative Reconstruction on Trabecular Bone Microstructure Assessment.

    Science.gov (United States)

    Kopp, Felix K; Holzapfel, Konstantin; Baum, Thomas; Nasirudin, Radin A; Mei, Kai; Garcia, Eduardo G; Burgkart, Rainer; Rummeny, Ernst J; Kirschke, Jan S; Noël, Peter B

    2016-01-01

    We investigated the effects of low-dose multi detector computed tomography (MDCT) in combination with statistical iterative reconstruction algorithms on trabecular bone microstructure parameters. Twelve donated vertebrae were scanned with the routine radiation exposure used in our department (standard-dose) and a low-dose protocol. Reconstructions were performed with filtered backprojection (FBP) and maximum-likelihood based statistical iterative reconstruction (SIR). Trabecular bone microstructure parameters were assessed and statistically compared for each reconstruction. Moreover, fracture loads of the vertebrae were biomechanically determined and correlated to the assessed microstructure parameters. Trabecular bone microstructure parameters based on low-dose MDCT and SIR significantly correlated with vertebral bone strength. There was no significant difference between microstructure parameters calculated on low-dose SIR and standard-dose FBP images. However, the results revealed a strong dependency on the regularization strength applied during SIR. It was observed that stronger regularization might corrupt the microstructure analysis, because the trabecular structure is a very small detail that might get lost during the regularization process. As a consequence, the introduction of SIR for trabecular bone microstructure analysis requires a specific optimization of the regularization parameters. Moreover, in comparison to other approaches, superior noise-resolution trade-offs can be found with the proposed methods.

  16. Estimating Effective Dose of Radiation From Pediatric Cardiac CT Angiography Using a 64-MDCT Scanner: New Conversion Factors Relating Dose-Length Product to Effective Dose.

    Science.gov (United States)

    Trattner, Sigal; Chelliah, Anjali; Prinsen, Peter; Ruzal-Shapiro, Carrie B; Xu, Yanping; Jambawalikar, Sachin; Amurao, Maxwell; Einstein, Andrew J

    2017-03-01

    The purpose of this study is to determine the conversion factors that enable accurate estimation of the effective dose (ED) used for cardiac 64-MDCT angiography performed for children. Anthropomorphic phantoms representative of 1- and 10-year-old children, with 50 metal oxide semiconductor field-effect transistor dosimeters placed in organs, underwent scanning performed using a 64-MDCT scanner with different routine clinical cardiac scan modes and x-ray tube potentials. Organ doses were used to calculate the ED on the basis of weighting factors published in 1991 in International Commission on Radiological Protection (ICRP) publication 60 and in 2007 in ICRP publication 103. The EDs and the scanner-reported dose-length products were used to determine conversion factors for each scan mode. The effect of infant heart rate on the ED and the conversion factors was also assessed. The mean conversion factors calculated using the current definition of ED that appeared in ICRP publication 103 were as follows: 0.099 mSv · mGy -1 · cm -1 , for the 1-year-old phantom, and 0.049 mSv · mGy -1 · cm -1 , for the 10-year-old phantom. These conversion factors were a mean of 37% higher than the corresponding conversion factors calculated using the older definition of ED that appeared in ICRP publication 60. Varying the heart rate did not influence the ED or the conversion factors. Conversion factors determined using the definition of ED in ICRP publication 103 and cardiac, rather than chest, scan coverage suggest that the radiation doses that children receive from cardiac CT performed using a contemporary 64-MDCT scanner are higher than the radiation doses previously reported when older chest conversion factors were used. Additional up-to-date pediatric cardiac CT conversion factors are required for use with other contemporary CT scanners and patients of different age ranges.

  17. Cystic Fibrosis: Are Volumetric Ultra-Low-Dose Expiratory CT Scans Sufficient for Monitoring Related Lung Disease?

    DEFF Research Database (Denmark)

    Loeve, Martine; Lequin, Maarten H; Bruijne, Marleen de

    2009-01-01

    Purpose: To assess whether chest computed tomography (CT) scores from ultra-low-dose end-expiratory scans alone could suffice for assessment of all cystic fibrosis (CF)-related structural lung abnormalities. Materials and Methods: In this institutional review board–approved study, 20 patients...... with CF aged 6–20 years (eight males, 12 females) underwent low-dose end-inspiratory CT and ultra-low-dose end-expiratory CT. Informed consent was obtained. Scans were randomized and scored by using the Brody-II CT scoring system to assess bronchiectasis, airway wall thickening, mucus plugging......-Altman plots. Results: Median age was 12.6 years (range, 6.3–20.3 years), median forced expiratory volume in 1 second was 100% (range, 46%–127%) of the predicted value, and median forced vital capacity was 99% (range, 61%–123%) of the predicted value. Very good agreement was observed between end...

  18. Survey of pediatric MDCT radiation dose from university hospitals in Thailand. A preliminary for national dose survey

    Energy Technology Data Exchange (ETDEWEB)

    Kritsaneepaiboon, Supika [Dept. of Radiology, Faculty of Medicine, Prince of Songkla Univ., Hat Yai (Thailand)], e-mail: supikak@yahoo.com; Trinavarat, Panruethai [Dept. of Radiology, Faculty of Medicine, Chulalongkorn Univ., Bangkok (Thailand); Visrutaratna, Pannee [Dept. of Radiology, Faculty of Medicine, Chiang Mai Univ., Chiang Mai (Thailand)

    2012-09-15

    Background: Increasing pediatric CT usage worldwide needs the optimization of CT protocol examination. Although there are previous published dose reference level (DRL) values, the local DRLs should be established to guide for clinical practice and monitor the CT radiation. Purpose: To determine the multidetector CT (MDCT) radiation dose in children in three university hospitals in Thailand in four age groups using the CT dose index (CTDI) and dose length product (DLP). Material and Methods: A retrospective review of CT dosimetry in pediatric patients (<15 years of age) who had undergone head, chest, and abdominal MDCT in three major university hospitals in Thailand was performed. Volume CTDI (CTDIvol) and DLP were recorded, categorized into four age groups: <1 year, 1- < 5 years, 5- <10 years, and 10- <15 years in each scanner. Range, mean, and third quartile values were compared with the national reference dose levels for CT in pediatric patients from the UK and Switzerland according to International Commission on Radiological Protection (ICRP) recommendation. Results: Per age group, the third quartile values for brain, chest, and abdominal CTs were, respectively, in terms of CTDIvol: 25, 30, 40, and 45 mGy; 4.5, 5.7, 10, and 15.6 mGy; 8.5, 9, 14, and 17 mGy; and in terms of DLP: 400, 570, 610, and 800 mGy cm; 80, 140, 305, and 470 mGy cm; and 190, 275, 560,765 mGy cm. Conclusion: This preliminary national dose survey for pediatric CT in Thailand found that the majority of CTDIvol and DLP values in brain, chest, and abdominal CTs were still below the diagnostic reference levels (DRLs) from the UK and Switzerland regarding to ICRP recommendation.

  19. Validity of linear measurements of the jaws using ultralow-dose MDCT and the iterative techniques of ASIR and MBIR.

    Science.gov (United States)

    Al-Ekrish, Asma'a A; Al-Shawaf, Reema; Schullian, Peter; Al-Sadhan, Ra'ed; Hörmann, Romed; Widmann, Gerlig

    2016-10-01

    To assess the comparability of linear measurements of dental implant sites recorded from multidetector computed tomography (MDCT) images obtained using standard-dose filtered backprojection (FBP) technique with those from various ultralow doses combined with FBP, adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR) techniques. The results of the study may contribute to MDCT dose optimization for dental implant site imaging. MDCT scans of two cadavers were acquired using a standard reference protocol and four ultralow-dose test protocols (TP). The volume CT dose index of the different dose protocols ranged from a maximum of 30.48-36.71 mGy to a minimum of 0.44-0.53 mGy. All scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Linear measurements were recorded from standardized images of the jaws by two examiners. Intra- and inter-examiner reliability of the measurements were analyzed using Cronbach's alpha and inter-item correlation. Agreement between the measurements obtained with the reference-dose/FBP protocol and each of the test protocols was determined with Bland-Altman plots and linear regression. Statistical significance was set at a P-value of 0.05. No systematic variation was found between the linear measurements obtained with the reference protocol and the other imaging protocols. The only exceptions were TP3/ASIR-50 (bone kernel) and TP4/ASIR-100 (bone and standard kernels). The mean measurement differences between these three protocols and the reference protocol were within ±0.1 mm, with the 95 % confidence interval limits being within the range of ±1.15 mm. A nearly 97.5 % reduction in dose did not significantly affect the height and width measurements of edentulous jaws regardless of the reconstruction algorithm used.

  20. Fractures of the thoracic spine in patients with minor trauma: Comparison of diagnostic accuracy and dose of biplane radiography and MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Karul, M., E-mail: m.karul@uke.de [Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany); Bannas, P.; Schoennagel, B.P.; Hoffmann, A.; Wedegaertner, U.; Adam, G.; Yamamura, J. [Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany)

    2013-08-15

    Objectives: To investigate the accuracy of biplane radiography in the detection of fractures of the thoracic spine in patients with minor trauma using multidetector computed tomography (MDCT) as the reference and to compare the dose of both techniques. Methods: 107 consecutive trauma patients with suspected fractures of the thoracic spine on physical examination were included. All had undergone biplane radiography first, followed by a MDCT scan between October 2008 and October 2012. A fourfold table was used for the classification of the screening test results. Both the Chi-square test (χ{sup 2}) and the mean dose-length product (DLP) were used to compare the diagnostic methods. Results: MDCT revealed 77 fractures in 65/107 patients (60.7%). Biplane radiography was true positive in 32/107 patients (29.9%), false positive in 19/107 patients (17.8%), true negative in 23/107 (21.5%) and false negative in 33/107 patients (30.8%), showing a sensitivity of 49.2%, a specificity of 54.7%, a positive predictive value (PPV) of 62.7%, a negative predictive value (NPV) of 41.1%, and an accuracy of 51.4%. The presence of a fracture on biplane radiography was highly statistical significant, if this was simultaneously proven by MDCT (χ{sup 2} = 7.6; p = 0.01). None of the fractures missed on biplane radiography was unstable. The mean DLP on biplane radiography was 14.5 mGy cm (range 1.9–97.8) and on MDCT 374.6 mGy cm (range 80.2–871). Conclusions: The sensitivity and the specificity of biplane radiography in the diagnosis of fractures of the thoracic spine in patients with minor trauma are low. Considering the wide availability of MDCT that is usually necessary for taking significant therapeutic steps, the indication for biplane radiography should be very restrictive.

  1. Effectiveness of Bismuth Shield to Reduce Eye Lens Radiation Dose Using the Photoluminescence Dosimetry in Computed Tomography

    International Nuclear Information System (INIS)

    Jung, Mi Young; Kweon, Dae Cheol; Kwon, Soo Il

    2009-01-01

    The purpose of our study was to determine the eye radiation dose when performing routine multi-detector computed tomography (MDCT). We also evaluated dose reduction and the effect on image quality of using a bismuth eye shield when performing head MDCT. Examinations were performed with a 64MDCT scanner. To compare the shielded/unshielded lens dose, the examination was performed with and without bismuth shielding in anthropomorphic phantom. To determine the average lens radiation dose, we imaged an anthropomorphic phantom into which calibrated photoluminescence glass dosimeter (PLD) were placed to measure the dose to lens. The phantom was imaged using the same protocol. Radiation doses to the lens with and without the lens shielding were measured and compared using the Student t test. In the qualitative evaluation of the MDCT scans, all were considered to be of diagnostic quality. We did not see any differences in quality between the shielded and unshielded brain. The mean radiation doses to the eye with the shield and to those without the shield were 21.54 versus 10.46 mGy, respectively. The lens shield enabled a 51.3% decrease in radiation dose to the lens. Bismuth in-plane shielding for routine eye and head MDCT decreased radiation dose to the lens without qualitative changes in image quality. The other radiosensitive superficial organs specifically must be protected with shielding.

  2. High-pitch computed tomography of the lung in pediatric patients. An intraindividual comparison of image quality and radiation dose to conventional 64-MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Tsiflikas, I.; Thomas, C.; Ketelsen, D.; Claussen, C.D.; Schaefer, J.F. [University Hospital of Tuebingen (Germany). Diagnostic and Interventional Radiology; Seitz, G.; Warmann, S. [University Hospital of Tuebingen (Germany). Pediatric Surgery

    2014-06-15

    Purpose: The aim of this study was to investigate frequencies of typical artifacts in low-dose pediatric lung examinations using high-pitch computed tomography (HPCT) compared to MDCT, and to estimate the effective radiation dose (E{sub eff}). Materials and Methods: Institutional review board approval for this retrospective study was obtained. 35 patients (17 boys, 18 girls; mean age 112 ± 69 months) were included and underwent MDCT and follow-up scan by HPCT or vice versa (mean follow-up time 87 days), using the same tube voltage and current. The total artifact score (0-8) was defined as the sum of artifacts arising from movement, breathing or pulsation of the heart or pulmonary vessels (0 - no; 1 - moderate; 2 - severe artifacts). E{sub eff} was estimated according to the European Guidelines on Quality Criteria for Multislice Computed Tomography. The Mann-Whitney U test was used to analyze differences between the patient groups. The Spearman's rank correlation coefficient was used for correlation of ordinal variables. Results: The scan time was significantly lower for HPCT compared to MDCT (0.72 ± 0.13 s vs. 3.65 ± 0.81s; p < 0.0001). In 28 of 35 (80 %) HPCT examinations no artifacts were visible, whereas in MDCT artifacts occurred in all examinations. The frequency of pulsation artifacts and breathing artifacts was higher in MDCT compared to HPCT (100% vs. 17% and 31% vs. 6%). The total artifact score significantly correlated with the patient's age in MDCT (r=-0.42; p=0.01), but not in HPCT (r=-0.32; p=0.07). The estimated E{sub eff} was significantly lower in HPCT than in MDCT (1.29±0.31 vs. 1.47±0.37 mSv; p < 0.0001). Conclusion: Our study indicates that the use of HPCT has advantages for pediatric lung imaging with a reduction of breathing and pulsation artifacts. Moreover, the estimated E{sub eff} was lower. In addition, examinations can be performed without sedation or breath-hold without losing image quality. (orig.)

  3. The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: Using CTDIvol to account for differences between scanners

    International Nuclear Information System (INIS)

    Turner, Adam C.; Zankl, Maria; DeMarco, John J.; Cagnon, Chris H.; Zhang Di; Angel, Erin; Cody, Dianna D.; Stevens, Donna M.; McCollough, Cynthia H.; McNitt-Gray, Michael F.

    2010-01-01

    Purpose: Monte Carlo radiation transport techniques have made it possible to accurately estimate the radiation dose to radiosensitive organs in patient models from scans performed with modern multidetector row computed tomography (MDCT) scanners. However, there is considerable variation in organ doses across scanners, even when similar acquisition conditions are used. The purpose of this study was to investigate the feasibility of a technique to estimate organ doses that would be scanner independent. This was accomplished by assessing the ability of CTDI vol measurements to account for differences in MDCT scanners that lead to organ dose differences. Methods: Monte Carlo simulations of 64-slice MDCT scanners from each of the four major manufacturers were performed. An adult female patient model from the GSF family of voxelized phantoms was used in which all ICRP Publication 103 radiosensitive organs were identified. A 120 kVp, full-body helical scan with a pitch of 1 was simulated for each scanner using similar scan protocols across scanners. From each simulated scan, the radiation dose to each organ was obtained on a per mA s basis (mGy/mA s). In addition, CTDI vol values were obtained from each scanner for the selected scan parameters. Then, to demonstrate the feasibility of generating organ dose estimates from scanner-independent coefficients, the simulated organ dose values resulting from each scanner were normalized by the CTDI vol value for those acquisition conditions. Results: CTDI vol values across scanners showed considerable variation as the coefficient of variation (CoV) across scanners was 34.1%. The simulated patient scans also demonstrated considerable differences in organ dose values, which varied by up to a factor of approximately 2 between some of the scanners. The CoV across scanners for the simulated organ doses ranged from 26.7% (for the adrenals) to 37.7% (for the thyroid), with a mean CoV of 31.5% across all organs. However, when organ doses

  4. Correlation of 64 row MDCT, echocardiography and cardiac catheterization angiography in assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease

    International Nuclear Information System (INIS)

    Chandrashekhar, Guruprasadh; Sodhi, Kushaljit Singh; Saxena, Akshay Kumar; Rohit, Manoj Kumar; Khandelwal, Niranjan

    2012-01-01

    Objective: To study the correlation of low-dose 64-row multi-detector computed tomography (MDCT) with echocardiography and cardiac catheterization angiography (CCA) in the assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease (CCHD). Materials and methods: This prospective study included 105 children (74 males, 31 females) with CCHD, in the age group of 2 months to 20 years, who underwent 64-row MDCT examination (low-dose CT protocol), echocardiography and CCA for the assessment of pulmonary arteries, including visualization, presence of confluence, stenosis and collaterals. Statistical analysis was performed using the non-parametric statistical analysis test to evaluate the concordance or discordance between echocardiography, MDCT and CCA. Results: 64-row MDCT detected significantly more main and branch pulmonary arteries, patent pulmonary confluences, and more cases of pulmonary artery stenosis. CCA detected more major aorto-pulmonary collaterals than MDCT, whereas echocardiography failed to identify these major aorto-pulmonary collaterals. The effective CT radiation dose to patients less than 2 years of age was in the range of 0.7–2.5 mSv, where as the dose in patients more than 2 years of age ranged from that of 2.1 to 4.2 mSv, which is much less than the radiation dose reported in cardiac catheterization angiography. Conclusion: In cases where cardiac MRI cannot be performed, or is not sufficiently informative, low-dose 64-row MDCT correlates well with CCA and can provide adequate information about pulmonary arterial anatomy in children with cyanotic congenital heart disease, and can replace invasive cardiac catheterization angiography with markedly reduced radiation dosage to the patient.

  5. The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations

    Science.gov (United States)

    Gu, J.; Bednarz, B.; Caracappa, P. F.; Xu, X. G.

    2009-05-01

    The latest multiple-detector technologies have further increased the popularity of x-ray CT as a diagnostic imaging modality. There is a continuing need to assess the potential radiation risk associated with such rapidly evolving multi-detector CT (MDCT) modalities and scanning protocols. This need can be met by the use of CT source models that are integrated with patient computational phantoms for organ dose calculations. Based on this purpose, this work developed and validated an MDCT scanner using the Monte Carlo method, and meanwhile the pregnant patient phantoms were integrated into the MDCT scanner model for assessment of the dose to the fetus as well as doses to the organs or tissues of the pregnant patient phantom. A Monte Carlo code, MCNPX, was used to simulate the x-ray source including the energy spectrum, filter and scan trajectory. Detailed CT scanner components were specified using an iterative trial-and-error procedure for a GE LightSpeed CT scanner. The scanner model was validated by comparing simulated results against measured CTDI values and dose profiles reported in the literature. The source movement along the helical trajectory was simulated using the pitch of 0.9375 and 1.375, respectively. The validated scanner model was then integrated with phantoms of a pregnant patient in three different gestational periods to calculate organ doses. It was found that the dose to the fetus of the 3 month pregnant patient phantom was 0.13 mGy/100 mAs and 0.57 mGy/100 mAs from the chest and kidney scan, respectively. For the chest scan of the 6 month patient phantom and the 9 month patient phantom, the fetal doses were 0.21 mGy/100 mAs and 0.26 mGy/100 mAs, respectively. The paper also discusses how these fetal dose values can be used to evaluate imaging procedures and to assess risk using recommendations of the report from AAPM Task Group 36. This work demonstrates the ability of modeling and validating an MDCT scanner by the Monte Carlo method, as well as

  6. The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations

    International Nuclear Information System (INIS)

    Gu, J; Bednarz, B; Caracappa, P F; Xu, X G

    2009-01-01

    The latest multiple-detector technologies have further increased the popularity of x-ray CT as a diagnostic imaging modality. There is a continuing need to assess the potential radiation risk associated with such rapidly evolving multi-detector CT (MDCT) modalities and scanning protocols. This need can be met by the use of CT source models that are integrated with patient computational phantoms for organ dose calculations. Based on this purpose, this work developed and validated an MDCT scanner using the Monte Carlo method, and meanwhile the pregnant patient phantoms were integrated into the MDCT scanner model for assessment of the dose to the fetus as well as doses to the organs or tissues of the pregnant patient phantom. A Monte Carlo code, MCNPX, was used to simulate the x-ray source including the energy spectrum, filter and scan trajectory. Detailed CT scanner components were specified using an iterative trial-and-error procedure for a GE LightSpeed CT scanner. The scanner model was validated by comparing simulated results against measured CTDI values and dose profiles reported in the literature. The source movement along the helical trajectory was simulated using the pitch of 0.9375 and 1.375, respectively. The validated scanner model was then integrated with phantoms of a pregnant patient in three different gestational periods to calculate organ doses. It was found that the dose to the fetus of the 3 month pregnant patient phantom was 0.13 mGy/100 mAs and 0.57 mGy/100 mAs from the chest and kidney scan, respectively. For the chest scan of the 6 month patient phantom and the 9 month patient phantom, the fetal doses were 0.21 mGy/100 mAs and 0.26 mGy/100 mAs, respectively. The paper also discusses how these fetal dose values can be used to evaluate imaging procedures and to assess risk using recommendations of the report from AAPM Task Group 36. This work demonstrates the ability of modeling and validating an MDCT scanner by the Monte Carlo method, as well as

  7. Multi detector computed tomography (MDCT) of the aortic root; ECG-gated verses non-ECG-gated examinations

    International Nuclear Information System (INIS)

    Kristiansen, Joanna; Guenther, Anne; Aalokken, Trond Mogens; Andersen, Rune

    2011-01-01

    Purpose: Motion artifacts may degrade a conventional CT examination of the ascending aorta and hinder accurate diagnosis. We quantitatively compared retrospectively electrocardiographic (ECG) -gated multi detector computed tomography (MDCT) with non-ECG-gated MDCT in order to demonstrate whether or not one of the methods should be preferred. Method: The study included seventeen patients with surgically reconstructed aortic root and reimplanted coronary arteries. All patients had undergone both non-gated MDCT and retrospectively ECG-gated MDCT employing a stringently modulated tube current with single phase image reconstruction. The incidence of motion artifacts in the left main coronary artery (LM), proximal right coronary artery (RCA), and aortic root and ascending aorta were rated using a four point scale. The effective dose for each scan was calculated and normalized to a 15 cm scan length. Statistical analysis of motion artifacts and radiation dose was performed using Wilcoxon matched pairs signed rank sum test. Results: A significant reduction in motion artifacts was found in all three vessels in images from the retrospectively ECG-gated scans (LM: P = 0.005, RCA: P = 0.015, aorta: P = 0.003). The mean normalized effective radiation dose was 3.69 mSv (±1.03) for the non-ECG-gated scans and 16.37 mSv (±2.53) for the ECG-gated scans. Conclusion: Retrospective ECG-gating with single phase reconstruction significantly reduces the incidence of motion artifacts in the aortic root and the proximal portion of the coronary arteries but at the expense of a fourfold increase in radiation dose.

  8. MDCT coronary angiography, postprocessing, reading, and reporting - Last but not least

    International Nuclear Information System (INIS)

    Marano, Riccardo; Savino, Giancarlo; Merlino, Biagio; Verrillo, Gemma; Silvestri, Valentina; Tricarico, Francesco; Meduri, Agostino; Natale, Luigi; Bonomo, Lorenzo

    2013-01-01

    Significant literature on MDCT coronary angiography (MDCT-CA) has emerged in the last decade concerning patient's selection, technical aspects of different generations of CT equipment, ECG gating, contrast material and beta-blockade administration, acquisition parameters, and radiation dose. However, the literature regarding postprocessing, reading, and reporting is not so extensive. This review highlights the main elements of MDCT-CA data analysis, thereby allowing the radiologist to take full advantage of this technology and enable a structured report to be generated, promoting best practice with high-quality results

  9. Effect of ultra-low doses, ASIR and MBIR on density and noise levels of MDCT images of dental implant sites.

    Science.gov (United States)

    Widmann, Gerlig; Al-Shawaf, Reema; Schullian, Peter; Al-Sadhan, Ra'ed; Hörmann, Romed; Al-Ekrish, Asma'a A

    2017-05-01

    Differences in noise and density values in MDCT images obtained using ultra-low doses with FBP, ASIR, and MBIR may possibly affect implant site density analysis. The aim of this study was to compare density and noise measurements recorded from dental implant sites using ultra-low doses combined with FBP, ASIR, and MBIR. Cadavers were scanned using a standard protocol and four low-dose protocols. Scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Density (mean Hounsfield units [HUs]) of alveolar bone and noise levels (mean standard deviation of HUs) was recorded from all datasets and measurements were compared by paired t tests and two-way ANOVA with repeated measures. Significant differences in density and noise were found between the reference dose/FBP protocol and almost all test combinations. Maximum mean differences in HU were 178.35 (bone kernel) and 273.74 (standard kernel), and in noise, were 243.73 (bone kernel) and 153.88 (standard kernel). Decreasing radiation dose increased density and noise regardless of reconstruction technique and kernel. The effect of reconstruction technique on density and noise depends on the reconstruction kernel used. • Ultra-low-dose MDCT protocols allowed more than 90 % reductions in dose. • Decreasing the dose generally increased density and noise. • Effect of IRT on density and noise varies with reconstruction kernel. • Accuracy of low-dose protocols for interpretation of bony anatomy not known. • Effect of low doses on accuracy of computer-aided design models unknown.

  10. MDCT of acute pancreatitis: Intraindividual comparison of single-phase versus dual-phase MDCT for initial assessment of acute pancreatitis using different CT scoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Avanesov, Maxim, E-mail: m.avanesov@uke.de [Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg (Germany); Weinrich, Julius M.; Kraus, Thomas [Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg (Germany); Derlin, Thorsten [Department of Nuclear Medicine, Hannover Medical School (Germany); Adam, Gerhard; Yamamura, Jin [Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg (Germany); Karul, Murat [Department of Diagnostic and Interventional Radiology, Marienkrankenhaus Hamburg (Germany)

    2016-11-15

    Objectives: The purpose of the retrospective study was to evaluate the additional value of dual-phase multidetector computed tomography (MDCT) protocols over a single-phase protocol on initial MDCT in patients with acute pancreatitis using three CT-based pancreatitis severity scores with regard to radiation dose. Methods: In this retrospective, IRB approved study MDCT was performed in 102 consecutive patients (73 males; 55years, IQR48–64) with acute pancreatitis. Inclusion criteria were CT findings of interstitial edematous pancreatitis (IP) or necrotizing pancreatitis (NP) and a contrast-enhanced dual-phase (arterial phase and portal-venous phase) abdominal CT performed at ≥72 h after onset of symptoms. The severity of pancreatic and extrapancreatic changes was independently assessed by 2 observers using 3 validated CT-based scoring systems (CTSI, mCTSI, EPIC). All scores were applied to arterial phase and portal venous phase scans and compared to score results of portal venous phase scans, assessed ≥14 days after initial evaluation. For effective dose estimation, volume CT dose index (CTDIvol) and dose length product (DLP) were recorded in all examinations. Results: In neither of the CT severity scores a significant difference was observed after application of a dual-phase protocol compared with a single-phase protocol (IP: CTSI: 2.7 vs. 2.5, p = 0.25; mCTSI: 4.0 vs. 4.0, p = 0.10; EPIC: 2.0 vs. 2.0, p = 0.41; NP: CTSI: 8.0 vs. 7.0, p = 0.64; mCTSI: 8.0 vs. 8.0, p = 0.10; EPIC: 3.0 vs. 3.0, p = 0.06). The application of a single-phase CT protocol was associated with a median effective dose reduction of 36% (mean dose reduction 31%) compared to a dual-phase CT scan. Conclusions: An initial dual-phase abdominal CT after ≥72 h after onset of symptoms of acute pancreatitis was not superior to a single-phase protocol for evaluation of the severity of pancreatic and extrapancreatic changes. However, the effective radiation dose may be reduced by 36% using a

  11. Step-and-shoot prospectively ECG-gated versus retrospectively ECG-gated with tube current modulation coronary CT angiography using the 128-slice MDCT: comparison of image quality and radiation dose

    International Nuclear Information System (INIS)

    Jeong, Dong Wook; Choo, Ki Seok; Baik, Seung Kug; Kim, Yong Woo; Jeon, Ung Bae; Kim, Jeong Soo; Lim, Soo Jin

    2011-01-01

    Background: Little is known regarding image quality and the required radiation dose for step-and-shoot and retrospective coronary computed tomography angiography (CCTA) with tube current modulation (TCM) in 128-slice multidetector CT (MDCT) coronary angiography. Purpose: To compare image quality and radiation dose in patients who underwent 128-slice MDCT by the step-and- shoot method with those in patients who underwent 128-slice MDCT with retrospective CCTA with TCM. Material and Methods: CCTA obtained with 128-slice MDCT was retrospectively evaluated in 160 patients. Two independent reviewers separately scored the subjective image quality of the coronary artery segments (1, excellent; 4, poor) for step-and-shoot (68, mean heart rate [HR]: 59.3±6.8) and retrospective CCTA with TCM (77, mean HR: 59.1±9.8). Interobserver variability was calculated. Effective radiation doses of both scan techniques were calculated with dose-length product. Results: There was good agreement for quality scores of coronary artery segment images between the independent reviewers (k=0.72). The number of coronary artery segments that could not be evaluated was 2.85% (27 of 947) in the step-and-shoot and 1.87% (20 of 1071) in retrospective CCTA with TCM. Image quality scores were not significantly different (P>.05). Mean patient radiation dose was 63% lower for step-and-shoot (1.94±0.70 mSv) than for retrospective CCTA with TCM (4.51±1.18 mSv) (P<0.0001). For patients who underwent step-and-shoot or retrospective CCTA with TCM, an average HR of 63.5 beats per minute was identified as the threshold for the prediction of non-diagnostic image quality for both protocols. There were no significant differences in the image quality of both methods between obese (body mass index [BMI≥25) and non-obese patients (BMI<25), but radiation doses were higher in the obesity group than in the non-obesity group for both methods. Conclusion: Both step-and-shoot and retrospective CCTA with TCM using 128

  12. The optimal dose reduction level using iterative reconstruction with prospective ECG-triggered coronary CTA using 256-slice MDCT

    International Nuclear Information System (INIS)

    Hou, Yang; Xu, Shu; Guo, Wenli; Vembar, Mani; Guo, Qiyong

    2012-01-01

    Aim: To assess the image quality (IQ) of an iterative reconstruction (IR) technique (iDose 4 ) from prospective electrocardiography (ECG)-triggered coronary computed tomography angiography (coronary CTA) on a 256-slice multi-detector CT (MDCT) scanner and determine the optimal dose reduction using IR that can provide IQ comparable to filtered back projection (FBP). Method and materials: 110 consecutive patients (69 men, 41 women; age: 54 ± 10 years) underwent coronary CTA on a 256-slice MDCT (Brilliance iCT, Philips Healthcare). The control group (Group A, n = 21) were scanned using the conventional tube output (120 kVp, 210 mAs) and reconstructed using FBP. The other 4 groups were scanned with the same kVp but successively reduced tube output as follows: B[n = 15]: 125 mAs; C[n = 22]: 105 mAs; D[n = 36]: 84 mAs: E[n = 16]: 65 mAs) and reconstructed using IR levels of L3 (Group B), L4 (Group C) and L5 (Groups D and E), to compensate for the noise increase. All images were reconstructed using the same kernel (XCB). Two radiologists graded IQ in a blinded fashion on a 4-point scale (4 – excellent, 3 – good, 2 – fair and 1 – poor). Quantitative measurements of CT values, image noise and contrast-to-noise (CNR) were measured in each group. A receiver-operating characteristic (ROC) analysis was performed to determine a radiation reduction threshold up to which excellent IQ was maintained. Results: There were no significant differences in objective noise, SNR and CNR values among Groups A, B, C, D, and E (P = 0.14, 0.09, 0.17, respectively). There were no significant differences in the scores of the subjective IQ between Group A, and Groups B, C, D, E (P = 0.23–0.97). Significant differences in image sharpness and study acceptability were observed between groups A and E (P < 0.05). Using the criterion of excellent IQ (score 4), the ROC curve of dose levels and IQ acceptability established a reduction of 60% of tube output (Group D) as optimum cutoff point (AUC

  13. Optimization of 64-MDCT urography: effect of dual-phase imaging with furosemide on collecting system opacification and radiation dose.

    Science.gov (United States)

    Portnoy, Orith; Guranda, Larisa; Apter, Sara; Eiss, David; Amitai, Marianne Michal; Konen, Eli

    2011-11-01

    The purpose of this study was to compare opacification of the urinary collecting system and radiation dose associated with three-phase 64-MDCT urographic protocols and those associated with a split-bolus dual-phase protocol including furosemide. Images from 150 CT urographic examinations performed with three scanning protocols were retrospectively evaluated. Group A consisted of 50 sequentially registered patients who underwent a three-phase protocol with saline infusion. Group B consisted of 50 sequentially registered patients who underwent a reduced-radiation three-phase protocol with saline. Group C consisted of 50 sequentially registered patients who underwent a dual-phase split-bolus protocol that included a low-dose furosemide injection. Opacification of the urinary collecting system was evaluated with segmental binary scoring. Contrast artifacts were evaluated, and radiation doses were recorded. Results were compared by analysis of variance. A significant reduction in mean effective radiation dose was found between groups A and B (p < 0.001) and between groups B and C (p < 0.001), resulting in 65% reduction between groups A and C (p < 0.001). This reduction did not significantly affect opacification score in any of the 12 urinary segments (p = 0.079). In addition, dense contrast artifacts overlying the renal parenchyma observed with the three-phase protocols (groups A and B) were avoided with the dual-phase protocol (group C) (p < 0.001). A dual-phase protocol with furosemide injection is the preferable technique for CT urography. In comparison with commonly used three-phase protocols, the dual-phase protocol significantly reduces radiation exposure dose without reduction in image quality.

  14. Comparison of 640-Slice Multidetector Computed Tomography Versus 32-Slice MDCT for Imaging of the Osteo-odonto-keratoprosthesis Lamina.

    Science.gov (United States)

    Norris, Joseph M; Kishikova, Lyudmila; Avadhanam, Venkata S; Koumellis, Panos; Francis, Ian S; Liu, Christopher S C

    2015-08-01

    To investigate the efficacy of 640-slice multidetector computed tomography (MDCT) for detecting osteo-odonto laminar resorption in the osteo-odonto-keratoprosthesis (OOKP) compared with the current standard 32-slice MDCT. Explanted OOKP laminae and bone-dentine fragments were scanned using 640-slice MDCT (Aquilion ONE; Toshiba) and 32-slice MDCT (LightSpeed Pro32; GE Healthcare). Pertinent comparisons including image quality, radiation dose, and scanning parameters were made. Benefits of 640-slice MDCT over 32-slice MDCT were shown. Key comparisons of 640-slice MDCT versus 32-slice MDCT included the following: percentage difference and correlation coefficient between radiological and anatomical measurements, 1.35% versus 3.67% and 0.9961 versus 0.9882, respectively; dose-length product, 63.50 versus 70.26; rotation time, 0.175 seconds versus 1.000 seconds; and detector coverage width, 16 cm versus 2 cm. Resorption of the osteo-odonto lamina after OOKP surgery can result in potentially sight-threatening complications, hence it warrants regular monitoring and timely intervention. MDCT remains the gold standard for radiological assessment of laminar resorption, which facilitates detection of subtle laminar changes earlier than the onset of clinical signs, thus indicating when preemptive measures can be taken. The 640-slice MDCT exhibits several advantages over traditional 32-slice MDCT. However, such benefits may not offset cost implications, except in rare cases, such as in young patients who might undergo years of radiation exposure.

  15. Usefulness of multidetector-row computed tomography (MD-CT) for diagnosis and evaluation of cardiovascular anomalies in infants

    International Nuclear Information System (INIS)

    Kani, Hiroyuki; Narabayashi, Isamu; Tanikake, Masato; Matsuki, Mitsuru; Uesugi, Yasuo

    2005-01-01

    We examined the effectiveness of multidetector-row CT (MD-CT) in the diagnosis and evaluation of cardiovascular anomalies in infants. MD-CT was performed 34 times on 21 patients with cardiovascular anomalies. We performed three evaluations: 1) The assessment of the specificity of MD-CT in detecting the morphological features of cardiovascular anomalies. 2) The diameters of aortae with coronary artery (CoA), and the diameters of pulmonary artery, measured by using MD-CT were compared with those by angiography. 3) The amount of exposure to radiation was measured. 1) MD-CT can detect CoA, pulmonary arteriovenous anomalies among extracardiac anomalies in all the patients. The diagnostic accuracy for intracardiac anomalies was poor as only six of the 15 anomalies could be accurately diagnosed. 2) The diameters of aortae and pulmonary artery obtained using MD-CT showed a good correlation with those obtained using arteriography (r=0.97, 0.95). 3) The average dose-length product was 269.2 mGy·cm. And the average effective dose was 5.1 mSv. MD-CT is not suitable for the evaluation of intracardiac anomalies, but is extremely effective in the evaluation of extracardiac major vascular anomalies. On the basis of the amount of information and noninvasive nature, MD-CT should be used first before angiography. (author)

  16. Follow-up of coronary artery bypass graft patency: diagnostic efficiency of high-pitch dual-source 256-slice MDCT findings.

    Science.gov (United States)

    Yuceler, Zeyneb; Kantarci, Mecit; Yuce, Ihsan; Kizrak, Yesim; Bayraktutan, Ummugulsum; Ogul, Hayri; Kiris, Adem; Celik, Omer; Pirimoglu, Berhan; Genc, Berhan; Gundogdu, Fuat

    2014-01-01

    Our aim was to evaluate the diagnostic accuracy of 256-slice, high-pitch mode multidetector computed tomography (MDCT) for coronary artery bypass graft (CABG) patency. Eighty-eight patients underwent 256-slice MDCT angiography to evaluate their graft patency after CABG surgery using a prospectively synchronized electrocardiogram in the high-pitch spiral acquisition mode. Effective radiation doses were calculated. We investigated the diagnostic accuracy of high-pitch, low-dose, prospective, electrocardiogram-triggering, dual-source MDCT for CABG patency compared with catheter coronary angiography imaging findings. A total of 215 grafts and 645 vessel segments were analyzed. All graft segments had diagnostic image quality. The proximal and middle graft segments had significantly (P < 0.05) better mean image quality scores (1.18 ± 0.4) than the distal segments (1.31 ± 0.5). Using catheter coronary angiography as the reference standard, high-pitch MDCT had the following sensitivity, specificity, positive predictive value, and negative predictive value of per-segment analysis for detecting graft patency: 97.1%, 99.6%, 94.4%, and 99.8%, respectively. In conclusion, MDCT can be used noninvasively with a lower radiation dose for the assessment of restenosis in CABG patients.

  17. Step-and-shoot prospectively ECG-gated vs. retrospectively ECG-gated with tube current modulation coronary CT angiography using 128-slice MDCT patients with chest pain: diagnostic performance and radiation dose

    International Nuclear Information System (INIS)

    Kim, Jeong Su; Choo, Ki Seok; Jeong, Dong Wook

    2011-01-01

    Background With increasing awareness for radiation exposure, the study of diagnostic accuracy of coronary CT angiography (CCTA) with low radiation dose techniques is mandatory to both radiologist and clinician. Purpose To compare diagnostic performance and effective radiation dose between step-and-shoot prospectively ECG-gated and retrospectively ECG-gated with tube current modulation (TCM) CCTA using 128-slice multidetector computed tomography (MDCT). Material and Methods We retrospectively evaluated 60 patients who underwent CCTA with either of two different low-dose techniques using 128-slice MDCT (23 patients for step-and shoot-prospectively ECG-gated and 37 patients for retrospectively ECG-gated with TCM CCTA) followed by conventional coronary angiography. All coronary arteries and all segments thereof, except anatomical variants or small size (< 1.5 mm) ones, were included in analysis. Results In per-segment analysis, sensitivity, specificity, positive predictive value, and negative predictive value were 91/96%, 95/94%, 75/73%, and 98/99% for step-and-shoot prospectively ECG-gated and retrospectively ECG gated with TCM CCTA, respectively, relative to conventional coronary angiography. Effective radiation dose were 1.75 ± 0.83 mSv, 4.91 ± 1.71 mSv in the step-and-shoot prospectively ECG-gated and retrospectively ECG-gated with TCM CCTA groups, respectively. Conclusion The two low-radiation dose CCTA techniques using 128-slice MDCT yields comparable diagnostic performance for coronary artery disease in symptomatic patients with low heart rates

  18. Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning

    International Nuclear Information System (INIS)

    Chung, Gi Chung; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Effective doses in μSv (E2007) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

  19. Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Gi Chung; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-03-15

    This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Effective doses in {mu}Sv (E2007) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

  20. Determining gastric cancer resectability by dynamic MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Zilai; Zhang, Huan; Du, Lianjun; Ding, Bei; Song, Qi; Ling, Huawei; Huang, Baisong; Chen, Kemin [Jiaotong University, Department of Radiology, Shanghai (China); Yan, Chao [Jiaotong University, Department of Surgery, Shanghai (China)

    2010-03-15

    Multi-detector row CT (MDCT) has been widely used to detect primary lesions and to evaluate TNM staging. In this study we evaluated the accuracy of dynamic MDCT in the preoperative determination of the resectability of gastric cancer. MDCT was used to image 350 cases of gastric cancer diagnosed by biopsy before surgery. MDCT findings regarding TNM staging and resectability were correlated with surgical and pathological findings. The accuracy of MDCT for staging gastric cancer was high, especially for tumour stage T1 (94.3%), lymph node stage N2 (87.3%), and for predicting distant metastases (>96.6%). When resectability was considered to be the outcome, the total accuracy of MDCT was 87.4%, sensitivity was 89.7% and specificity was 76.7%. Results showed high sensitivity for identifying peritoneal seeding (90.0%) and for predicting liver metastasis (80.0%). Dynamic enhanced MDCT is useful for TNM staging of gastric cancers and for predicting tumour respectability preoperatively. (orig.)

  1. Determining gastric cancer resectability by dynamic MDCT

    International Nuclear Information System (INIS)

    Pan, Zilai; Zhang, Huan; Du, Lianjun; Ding, Bei; Song, Qi; Ling, Huawei; Huang, Baisong; Chen, Kemin; Yan, Chao

    2010-01-01

    Multi-detector row CT (MDCT) has been widely used to detect primary lesions and to evaluate TNM staging. In this study we evaluated the accuracy of dynamic MDCT in the preoperative determination of the resectability of gastric cancer. MDCT was used to image 350 cases of gastric cancer diagnosed by biopsy before surgery. MDCT findings regarding TNM staging and resectability were correlated with surgical and pathological findings. The accuracy of MDCT for staging gastric cancer was high, especially for tumour stage T1 (94.3%), lymph node stage N2 (87.3%), and for predicting distant metastases (>96.6%). When resectability was considered to be the outcome, the total accuracy of MDCT was 87.4%, sensitivity was 89.7% and specificity was 76.7%. Results showed high sensitivity for identifying peritoneal seeding (90.0%) and for predicting liver metastasis (80.0%). Dynamic enhanced MDCT is useful for TNM staging of gastric cancers and for predicting tumour respectability preoperatively. (orig.)

  2. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT

    International Nuclear Information System (INIS)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U.

    2012-01-01

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI vol values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 ± 2.5 vs. 11.4 ± 1.4, p < 0.001; 14.2 ± 3.7 vs. 16.1 ± 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 ± 201.1 vs. 849.8 ± 90.9, p < 0,001; 504.4 ± 134.4 vs. 471.5 ± 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 ± 35.8 vs. 155.5 ± 12.3 (p < 0.001), thorax 427.4 ± 44.5 vs. 388.3 ± 57.5 (p < 0.001), abdomen 520.3 ± 50.2 vs. 490.8 ± 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 ± 2.6 (4-row MDCT) and 24.1 ± 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  3. The usefulness of MDCT in acute intestinal bleeding

    International Nuclear Information System (INIS)

    Kim, Kum Rae; Park, Won Kyu; Kim, Jae Woon; Chang, Jay Chun; Jang, Han Won

    2006-01-01

    We wanted to evaluate the usefulness of MDCT for localizing a bleeding site and for helping make a decision on further management for acute intestinal bleeding. We conducted a retrospective review of 17 consecutive patients who presented with acute intestinal bleeding and who also underwent MDCT before angiography or surgery. The sensitivity of MDCT for detecting acute intestinal bleeding was assessed and compared with that of conventional angiography. The sensitivity of MDCT for the detection of acute intestinal bleeding was 77% (13 or 17), whereas that of angiography was 46% (6 or 13). All the bleeding points that were subsequently detected on angiography were visualized on MDCT. In three cases, the bleeding focus was detected on MDCT and not on angiography. In four cases, both MDCT and angiography did not detect the bleeding focus; for one of these cases, CT during SMA angiography was performed and this detected the active bleeding site. In patients with acute intestinal bleeding, MDCT is a useful image modality to detect the bleeding site and to help decide on further management before performing angiography or surgery. When tumorous lesions are detected, invasive angiography can be omitted

  4. Perfusion CT of the Brain and Liver and of Lung Tumors: Use of Monte Carlo Simulation for Patient Dose Estimation for Examinations With a Cone-Beam 320-MDCT Scanner.

    Science.gov (United States)

    Cros, Maria; Geleijns, Jacob; Joemai, Raoul M S; Salvadó, Marçal

    2016-01-01

    The purpose of this study was to estimate the patient dose from perfusion CT examinations of the brain, lung tumors, and the liver on a cone-beam 320-MDCT scanner using a Monte Carlo simulation and the recommendations of the International Commission on Radiological Protection (ICRP). A Monte Carlo simulation based on the Electron Gamma Shower Version 4 package code was used to calculate organ doses and the effective dose in the reference computational phantoms for an adult man and adult woman as published by the ICRP. Three perfusion CT acquisition protocols--brain, lung tumor, and liver perfusion--were evaluated. Additionally, dose assessments were performed for the skin and for the eye lens. Conversion factors were obtained to estimate effective doses and organ doses from the volume CT dose index and dose-length product. The sex-averaged effective doses were approximately 4 mSv for perfusion CT of the brain and were between 23 and 26 mSv for the perfusion CT body protocols. The eye lens dose from the brain perfusion CT examination was approximately 153 mGy. The sex-averaged peak entrance skin dose (ESD) was 255 mGy for the brain perfusion CT studies, 157 mGy for the lung tumor perfusion CT studies, and 172 mGy for the liver perfusion CT studies. The perfusion CT protocols for imaging the brain, lung tumors, and the liver performed on a 320-MDCT scanner yielded patient doses that are safely below the threshold doses for deterministic effects. The eye lens dose, peak ESD, and effective doses can be estimated for other clinical perfusion CT examinations from the conversion factors that were derived in this study.

  5. Investigation of airways using MDCT for visual and quantitative assessment in COPD patients

    Directory of Open Access Journals (Sweden)

    Pierre-Yves Brillet

    2008-03-01

    Full Text Available Pierre-Yves Brillet1, Catalin I Fetita2, Amaury Saragaglia2, Anne-Laure Brun3, Catherine Beigelman-Aubry3, Françoise Prêteux2, Philippe A Grenier31Department of Radiology, Avicenne Hospital, Assistance Publique–Hôpitaux de Paris, Université Léonard de Vinci–Paris Nord, EA 2361, Bobigny, France; 2ARTEMIS Department, Institut National des Télécommunications, Université Paris V, Evry, France; 3Department of Radiology, Pitié-Salpêtrière Hospital, Assistance Publique–Hôpitaux de Paris, Université Pierre et Marie Curie, Paris, FranceAbstract: Multidetector computed tomography (MDCT acquisition during a single breath hold using thin collimation provides high resolution volumetric data set permitting multiplanar and three dimensional reconstruction of the proximal airways. In chronic obstructive pulmonary disease (COPD patients, this technique provides an accurate assessment of bronchial wall thickening, tracheobronchial deformation, outpouchings reflecting dilatation of the submucous glands, tracheobronchomalacia, and expiratory air trapping. New software developed to segment adequately the lumen and walls of the airways on MDCT scans allows quantitative assessment of the airway dimensions which has shown to be reliable in clinical practice. This technique can become important in longitudinal studies of the pathogenesis of COPD, and in the assessment of therapeutic interventions.Keywords: COPD – tracheobronchial tree, multidetector CT – airway remodeling, tracheobronchomalacia

  6. Optimised low-dose multidetector CT protocol for children with cranial deformity

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, Jose Luis [Complejo Hospitalario Universitario de Vigo, Department of Radiology, Vigo, Pontevedra (Spain); Pombar, Miguel Angel [Complejo Hospitalario Universitario de Santiago, Department of Radiophysics, Santiago de Compostela, La Coruna (Spain); Pumar, Jose Manuel [Complejo Hospitalario Universitario de Santiago, Department of Radiology, Santiago de Compostela, La Coruna (Spain); Campo, Victor Miguel del [Complejo Hospitalario Universitario de Vigo, Department of Public Health, Vigo, Pontevedra (Spain)

    2013-08-15

    To present an optimised low-dose multidetector computed tomography (MDCT) protocol for the study of children with cranial deformity. Ninety-one consecutive MDCT studies were performed in 80 children. Studies were performed with either our standard head CT protocol (group 1, n = 20) or a low-dose cranial deformity protocol (groups 2 and 3). Group 2 (n = 38), initial, and group 3 (n = 33), final and more optimised. All studies were performed in the same 64-MDCT equipment. Cranial deformity protocol was gradationally optimised decreasing kVp, limiting mA range, using automatic exposure control (AEC) and increasing the noise index (NI). Image quality was assessed. Dose indicators such us CT dose index volume (CTDIvol), dose-length product (DLP) and effective dose (E) were used. The optimised low-dose protocol reached the following values: 80 kVp, mA range: 50-150 and NI = 23. We achieved a maximum dose reduction of 10-22 times in the 1- to 12-month-old cranium in regard to the 2004 European guidelines for MDCT. A low-dose MDCT protocol that may be used as the first diagnostic imaging option in clinically selected patients with skull abnormalities. (orig.)

  7. Dose management as a measurable criteria into the quality control programme of an imaging diagnostic clinic

    International Nuclear Information System (INIS)

    Kirova, G.; Georgiev, E.; Zasheva, C.; Georgiev, S.

    2014-01-01

    In the Radiology Department of Tokuda Hospital Sofia, a strong control over the radiation dose for all patients was accepted with the implementation of the Dose Watch software. The system allows bad practices to be discovered and improves the efficiency and quality of the CT procedures performed in the department. The article will briefly demonstrate the main steps, which have been done, and the results, which have been achieved. The purpose is to identify the challenges, the available tools, and the opportunities for improving the patients' dose in the CT sector of a general Radiology Department. Collected data was based on the information concerning the radiation dose absorbed by individual patients undergoing MDCT examinations in a general radiology department with an overall annual rate of around 7000 MDCT examinations. All of them were carried out using a single 64row MDCT system. The hospital logbook was used to identify the number of CT examinations and dose levels associated with some typical diagnostic procedures in order to make an analysis. The information was taken form the PACS and Dose Watch software and was analyzed. The article draws some measures towards improving the organization and reducing the dose, keeping the quality of the performed exams. Thanks to the supportive software for dose tracking, analyzing and reporting, some problems have been solved and some reasonable measures have been implemented into the daily practice. (authors) Key words: RADIATION DOSE. MDCT. DOSE REDUCTION. REFERRAL GUIDELINES.CTDI. DLP

  8. Suspected pulmonary embolism and deep venous thrombosis: A comprehensive MDCT diagnosis in the acute clinical setting

    International Nuclear Information System (INIS)

    Salvolini, Luca; Scaglione, Mariano; Giuseppetti, Gian Marco; Giovagnoni, Andrea

    2008-01-01

    Both pulmonary arterial and peripheral venous sides of venous thromboembolism (VTE) can now be efficiently and safely investigated by multi-detector CT (MDCT) at the same time by a combined CT angiography/CT venography protocol. In the emergency setting, the use of such a single test for patients suspected of suffering from VTE on a clinical grounds may considerably shorten and simplify diagnostic algorithms. The selection of patients to be submitted to MDCT must follow well-established clinical prediction rules in order to avoid generalized referral to CT on a generic clinical suspicion basis and excessive population exposure to increased ionizing radiation dose, especially in young patients. Clinical and anatomical wide-panoramic capabilities of MDCT allow identification of underlying disease that may explain patients' symptoms in a large number of cases in which VTE is not manifest. The analysis of MDCT additional findings on cardiopulmonary status and total thrombus burden can lead to better prognostic stratification of patients and influence therapeutic options. Some controversial points such as optimal examination parameters, clinical significance of subsegmentary emboli, CT pitfalls and/or possible falsely positive diagnoses, and outcome of untreated patients in which VTE has been excluded by MDCT without additional testing, must of course be taken into careful consideration before the definite role of comprehensive MDCT VTE 'one-stop-shop' diagnosis in everyday clinical practice can be ascertained

  9. Suspected pulmonary embolism and deep venous thrombosis: A comprehensive MDCT diagnosis in the acute clinical setting

    Energy Technology Data Exchange (ETDEWEB)

    Salvolini, Luca [Radiology Department, ' Umberto I' Hospital - Ospedali Riuniti - ' Politecnica delle Marche' University, Via Conca, 60020 Ancona (Italy)], E-mail: lucasalvolini@alice.it; Scaglione, Mariano [Emergency and Trauma CT Section, Department of Radiology, Cardarelli Hospital, Via G. Merliani 31, 80127 Naples (Italy); Giuseppetti, Gian Marco; Giovagnoni, Andrea [Radiology Department, ' Umberto I' Hospital - Ospedali Riuniti - ' Politecnica delle Marche' University, Via Conca, 60020 Ancona (Italy)

    2008-03-15

    Both pulmonary arterial and peripheral venous sides of venous thromboembolism (VTE) can now be efficiently and safely investigated by multi-detector CT (MDCT) at the same time by a combined CT angiography/CT venography protocol. In the emergency setting, the use of such a single test for patients suspected of suffering from VTE on a clinical grounds may considerably shorten and simplify diagnostic algorithms. The selection of patients to be submitted to MDCT must follow well-established clinical prediction rules in order to avoid generalized referral to CT on a generic clinical suspicion basis and excessive population exposure to increased ionizing radiation dose, especially in young patients. Clinical and anatomical wide-panoramic capabilities of MDCT allow identification of underlying disease that may explain patients' symptoms in a large number of cases in which VTE is not manifest. The analysis of MDCT additional findings on cardiopulmonary status and total thrombus burden can lead to better prognostic stratification of patients and influence therapeutic options. Some controversial points such as optimal examination parameters, clinical significance of subsegmentary emboli, CT pitfalls and/or possible falsely positive diagnoses, and outcome of untreated patients in which VTE has been excluded by MDCT without additional testing, must of course be taken into careful consideration before the definite role of comprehensive MDCT VTE 'one-stop-shop' diagnosis in everyday clinical practice can be ascertained.

  10. Research of z-axis geometric dose efficiency in multi-detector computed tomography

    International Nuclear Information System (INIS)

    Kim, You Hyun; Kim, Moon Chan

    2006-01-01

    With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for

  11. Effect of ultra-low doses, ASIR and MBIR on density and noise levels of MDCT images of dental implant sites

    Energy Technology Data Exchange (ETDEWEB)

    Widmann, Gerlig; Schullian, Peter [Medical University of Innsbruck, Department of Radiology, Innsbruck (Austria); Al-Shawaf, Reema; Al-Sadhan, Ra' ed; Al-Ekrish, Asma' a A. [King Saud University, Department of Oral Medicine and Diagnostic Sciences, College of Dentistry, Riyadh (Saudi Arabia); Hoermann, Romed [Medical University of Innsbruck, Division of Clinical and Functional Anatomy, Innsbruck (Austria)

    2017-05-15

    Differences in noise and density values in MDCT images obtained using ultra-low doses with FBP, ASIR, and MBIR may possibly affect implant site density analysis. The aim of this study was to compare density and noise measurements recorded from dental implant sites using ultra-low doses combined with FBP, ASIR, and MBIR. Cadavers were scanned using a standard protocol and four low-dose protocols. Scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Density (mean Hounsfield units [HUs]) of alveolar bone and noise levels (mean standard deviation of HUs) was recorded from all datasets and measurements were compared by paired t tests and two-way ANOVA with repeated measures. Significant differences in density and noise were found between the reference dose/FBP protocol and almost all test combinations. Maximum mean differences in HU were 178.35 (bone kernel) and 273.74 (standard kernel), and in noise, were 243.73 (bone kernel) and 153.88 (standard kernel). Decreasing radiation dose increased density and noise regardless of reconstruction technique and kernel. The effect of reconstruction technique on density and noise depends on the reconstruction kernel used. (orig.)

  12. Effect of ultra-low doses, ASIR and MBIR on density and noise levels of MDCT images of dental implant sites

    International Nuclear Information System (INIS)

    Widmann, Gerlig; Schullian, Peter; Al-Shawaf, Reema; Al-Sadhan, Ra'ed; Al-Ekrish, Asma'a A.; Hoermann, Romed

    2017-01-01

    Differences in noise and density values in MDCT images obtained using ultra-low doses with FBP, ASIR, and MBIR may possibly affect implant site density analysis. The aim of this study was to compare density and noise measurements recorded from dental implant sites using ultra-low doses combined with FBP, ASIR, and MBIR. Cadavers were scanned using a standard protocol and four low-dose protocols. Scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Density (mean Hounsfield units [HUs]) of alveolar bone and noise levels (mean standard deviation of HUs) was recorded from all datasets and measurements were compared by paired t tests and two-way ANOVA with repeated measures. Significant differences in density and noise were found between the reference dose/FBP protocol and almost all test combinations. Maximum mean differences in HU were 178.35 (bone kernel) and 273.74 (standard kernel), and in noise, were 243.73 (bone kernel) and 153.88 (standard kernel). Decreasing radiation dose increased density and noise regardless of reconstruction technique and kernel. The effect of reconstruction technique on density and noise depends on the reconstruction kernel used. (orig.)

  13. Ultra-low dose abdominal MDCT: Using a knowledge-based Iterative Model Reconstruction technique for substantial dose reduction in a prospective clinical study

    International Nuclear Information System (INIS)

    Khawaja, Ranish Deedar Ali; Singh, Sarabjeet; Blake, Michael; Harisinghani, Mukesh; Choy, Gary; Karosmangulu, Ali; Padole, Atul; Do, Synho; Brown, Kevin; Thompson, Richard; Morton, Thomas; Raihani, Nilgoun; Koehler, Thomas; Kalra, Mannudeep K.

    2015-01-01

    Highlights: • Limited abdominal CT indications can be performed at a size specific dose estimate of (SSDE) 1.5 mGy (∼0.9 mSv) in smaller patients (BMI less than or equal to 25 kg/m 2 ) using a knowledge based Iterative Model Reconstruction (IMR) technique. • Evaluation of liver tumors and pathologies is unacceptable at this reduced dose with IMR technique especially in patients with a BMI greater than 25 kg/m 2 . • IMR body soft tissue and routine settings perform substantially better than IMR sharp plus setting in reduced dose CT images. • At SSDE of 1.5 mGy, objective image noise in reduced dose IMR images is 8–56% less than compared to standard dose FBP images, with lowest image noise in IMR body-soft tissue images. - Abstract: Purpose: To assess lesion detection and image quality parameters of a knowledge-based Iterative Model Reconstruction (IMR) in reduced dose (RD) abdominal CT examinations. Materials and methods: This IRB-approved prospective study included 82 abdominal CT examinations performed for 41 consecutive patients (mean age, 62 ± 12 years; F:M 28:13) who underwent a RD CT (SSDE, 1.5 mGy ± 0.4 [∼0.9 mSv] at 120 kV with 17–20 mAs/slice) immediately after their standard dose (SD) CT exam (10 mGy ± 3 [∼6 mSv] at 120 kV with automatic exposure control) on 256 MDCT (iCT, Philips Healthcare). SD data were reconstructed using filtered back projection (FBP). RD data were reconstructed with FBP and IMR. Four radiologists used a five-point scale (1 = image quality better than SD CT to 5 = image quality unacceptable) to assess both subjective image quality and artifacts. Lesions were first detected on RD FBP images. RD IMR and RD FBP images were then compared side-by-side to SD-FBP images in an independent, randomized and blinded fashion. Friedman's test and intraclass correlation coefficient were used for data analysis. Objective measurements included image noise and attenuation as well as noise spectral density (NSD) curves to

  14. Ultra-low dose abdominal MDCT: Using a knowledge-based Iterative Model Reconstruction technique for substantial dose reduction in a prospective clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Khawaja, Ranish Deedar Ali, E-mail: rkhawaja@mgh.harvard.edu [MGH Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Singh, Sarabjeet; Blake, Michael; Harisinghani, Mukesh; Choy, Gary; Karosmangulu, Ali; Padole, Atul; Do, Synho [MGH Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Brown, Kevin; Thompson, Richard; Morton, Thomas; Raihani, Nilgoun [CT Research and Advanced Development, Philips Healthcare, Cleveland, OH (United States); Koehler, Thomas [Philips Technologie GmbH, Innovative Technologies, Hamburg (Germany); Kalra, Mannudeep K. [MGH Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States)

    2015-01-15

    Highlights: • Limited abdominal CT indications can be performed at a size specific dose estimate of (SSDE) 1.5 mGy (∼0.9 mSv) in smaller patients (BMI less than or equal to 25 kg/m{sup 2}) using a knowledge based Iterative Model Reconstruction (IMR) technique. • Evaluation of liver tumors and pathologies is unacceptable at this reduced dose with IMR technique especially in patients with a BMI greater than 25 kg/m{sup 2}. • IMR body soft tissue and routine settings perform substantially better than IMR sharp plus setting in reduced dose CT images. • At SSDE of 1.5 mGy, objective image noise in reduced dose IMR images is 8–56% less than compared to standard dose FBP images, with lowest image noise in IMR body-soft tissue images. - Abstract: Purpose: To assess lesion detection and image quality parameters of a knowledge-based Iterative Model Reconstruction (IMR) in reduced dose (RD) abdominal CT examinations. Materials and methods: This IRB-approved prospective study included 82 abdominal CT examinations performed for 41 consecutive patients (mean age, 62 ± 12 years; F:M 28:13) who underwent a RD CT (SSDE, 1.5 mGy ± 0.4 [∼0.9 mSv] at 120 kV with 17–20 mAs/slice) immediately after their standard dose (SD) CT exam (10 mGy ± 3 [∼6 mSv] at 120 kV with automatic exposure control) on 256 MDCT (iCT, Philips Healthcare). SD data were reconstructed using filtered back projection (FBP). RD data were reconstructed with FBP and IMR. Four radiologists used a five-point scale (1 = image quality better than SD CT to 5 = image quality unacceptable) to assess both subjective image quality and artifacts. Lesions were first detected on RD FBP images. RD IMR and RD FBP images were then compared side-by-side to SD-FBP images in an independent, randomized and blinded fashion. Friedman's test and intraclass correlation coefficient were used for data analysis. Objective measurements included image noise and attenuation as well as noise spectral density (NSD) curves

  15. MDCT assessment of resectability in hilar cholangiocarcinoma.

    Science.gov (United States)

    Ni, Qihong; Wang, Haolu; Zhang, Yunhe; Qian, Lijun; Chi, Jiachang; Liang, Xiaowen; Chen, Tao; Wang, Jian

    2017-03-01

    The purpose of this study is to investigate the value of multidetector computed tomography (MDCT) assessment of resectability in hilar cholangiocarcinoma, and to identify the factors associated with unresectability and accurate evaluation of resectability. From January 2007 to June 2015, a total of 77 consecutive patients were included. All patients had preoperative MDCT (with MPR and MinIP) and surgical treatment, and were pathologically proven with hilar cholangiocarcinoma. The MDCT images were reviewed retrospectively by two senior radiologists and one hepatobiliary surgeon. The surgical findings and pathologic results were considered to be the gold standard. The Chi square test was used to identify factors associated with unresectability and accurate evaluation of resectability. The sensitivity, specificity, and overall accuracy of MDCT assessment were 83.3 %, 75.9 %, and 80.5 %, respectively. The main causes of inaccuracy were incorrect evaluation of N2 lymph node metastasis (4/15) and distant metastasis (4/15). Bismuth type IV tumor, main or bilateral hepatic artery involvement, and main or bilateral portal vein involvement were highly associated with unresectability (P hilar cholangiocarcinoma. Bismuth type IV tumor and main or bilateral vascular involvement highly suggest the unresectability of hilar cholangiocarcinoma. Patients without biliary drainage have a more accurate MDCT evaluation of resectability. We suggest MDCT should be performed before biliary drainage to achieve an accurate evaluation of resectability in hilar cholangiocarcinoma.

  16. The application of MDCT in the diagnosis of chest trauma.

    Science.gov (United States)

    Błasińska-Przerwa, Katarzyna; Pacho, Ryszard; Bestry, Iwona

    2013-01-01

    Traumas are the third most common cause of death worldwide, after cardiovascular diseases and neoplasms, and the main cause of death of patients under 40 years of age. Contemporary image diagnosis of chest trauma uses chest X-ray (CXR), multidetector computed tomography (MDCT), transthoracic and transoesophageal ultrasound (USG), X-ray angiography and magnetic resonance. The aim of the present study was to evaluate MDCT results in the examination of posttraumatic chest injuries and to compare the results of CXR and MDCT in chosen chest traumatic injuries. The sixty patients with chest trauma included in the study were diagnosed at the Department of Radiology of the Institute of Tuberculosis and Lung Diseases between May 2004 and October 2007. MDCT was performed in all patients. Two groups with different types of injury (blunt or penetrating chest trauma) were distinguished. The analysis of injuries in both groups was conducted depending on the mechanism of trauma. The detection of 20 selected injuries at CXR and MDCT was compared. Moreover, the compatibility of MDCT with the results of intraoperative assessment and bronchoscopy was analysed. The influence of MDCT on the treatment modality was also assessed. History of blunt chest trauma was found in 51 patients (group 1) and of penetrating trauma in 9 patients (group 2). The most frequent injuries among group 1 were lung contusion and rib fractures, and among group 2 it was pericardial hematoma. Compared to MDCT, the sensitivity and specificity of CXR were 66.7 and 58%, respectively. Change of treatment modality was observed after MDCT in 83% of patients. The sensitivity and specificity of MDCT in diagnosing tracheobronchial injury, compared to bronchoscopy, were 72.7% and 100%, respectively. Compatibility of MDCT results and intraoperative assessment was observed in 43% of patients, and the main reason for discrepancy was underdiagnosis of diaphragm injury in MDCT. MDCT was a valuable diagnostic method in

  17. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

    International Nuclear Information System (INIS)

    Jeong, Dae Kyo; Lee, Sang Chul; Huh, Kyung Hoe; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul

    2012-01-01

    The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. The effective dose was the highest for Somatom Sensation 10 (425.84 μSv), followed by AZ3000CT (332.4 μSv), Somatom Emotion 6 (199.38 μSv), and 3D eXaM (111.6 μSv); it was the lowest for Implagraphy (83.09 μSv). The CBCT showed significant variation in dose level with different device. The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

  18. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Dae Kyo; Lee, Sang Chul; Huh, Kyung Hoe; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2012-06-15

    The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. The effective dose was the highest for Somatom Sensation 10 (425.84 {mu}Sv), followed by AZ3000CT (332.4 {mu}Sv), Somatom Emotion 6 (199.38 {mu}Sv), and 3D eXaM (111.6 {mu}Sv); it was the lowest for Implagraphy (83.09 {mu}Sv). The CBCT showed significant variation in dose level with different device. The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

  19. Liver imaging with MDCT and high concentration contrast media

    International Nuclear Information System (INIS)

    Spielmann, Audrey L.

    2003-01-01

    Liver imaging has advanced greatly over the last 10 years with helical CT capability and more recently the addition of multidetector-row CT (MDCT). Multidetector CT technology facilitates imaging at faster speeds with improved image quality and less breathing artifact [Abdom. Imaging 25 (2000) 643]. Exquisite three-dimensional data sets can be obtained with thin collimation providing improved lesion detection, multiplanar imaging, and the ability to perform CT angiography of the liver and mesenteric vessels. New challenges arise with this advance in technology including safety considerations. The radiation dose to the patient has increased with MDCT and this is compounded by the ability to perform multi-phase liver imaging. Furthermore, issues of contrast media administration require reconsideration including optimal timing and rate of administration, the total volume of contrast needed and the ideal iodine concentration of the contrast media. Recently, the use of high concentration contrast media (HCCM) has been explored and study results to date will be reviewed

  20. [Comparison of radiation dose reduction of prospective ECG-gated one beat scan using 320 area detector CT coronary angiography and prospective ECG-gated helical scan with high helical pitch (FlashScan) using 64 multidetector-row CT coronary angiography].

    Science.gov (United States)

    Matsutani, Hideyuki; Sano, Tomonari; Kondo, Takeshi; Fujimoto, Shinichiro; Sekine, Takako; Arai, Takehiro; Morita, Hitomi; Takase, Shinichi

    2010-12-20

    A high radiation dose associated with 64 multidetector-row computed tomography (64-MDCT) is a major concern for physicians and patients alike. A new 320 row area detector computed tomography (ADCT) can obtain a view of the entire heart with one rotation (0.35 s) without requiring the helical method. As such, ADCT is expected to reduce the radiation dose. We studied image quality and radiation dose of ADCT compared to that of 64-MDCT in patients with a low heart rate (HR≤60). Three hundred eighty-five consecutive patients underwent 64-MDCT and 379 patients, ADCT. Patients with an arrhythmia were excluded. Prospective ECG-gated helical scan with high HP (FlashScan) in 64 was used for MDCT and prospective ECG-gated conventional one beat scan, for 320-ADCT. Image quality was visually evaluated by an image quality score. Radiation dose was estimated by DLP (mGy・cm) for 64-MDCT and DLP.e (mGy・cm) for 320-ADCT. Radiation dose of 320-ADCT (208±48 mGy・cm) was significantly (P<0.0001) lower than that of 64-MDCT (484±112 mGy・cm), and image quality score of 320-ADCT (3.0±0.2) was significantly (P=0.0011) higher than that of 64-MDCT (2.9±0.4). Scan time of 320-ADCT (1.4±0.1 s) was also significantly (P<0.0001) shorter than that of 64-MDCT (6.8±0.6 s). 320-ADCT can achieve not only a reduction in radiation dose but also a superior image quality and shortening of scan time compared to 64-MDCT.

  1. MDCT angiography and transcatheter embolization in management ...

    African Journals Online (AJOL)

    Hassan Abdelsalam

    2015-12-18

    Dec 18, 2015 ... 14 patients did not have a MDCT and proceeded straight to angiography;. 6 of them showed active bleeding on angiography. Conclusion: MDCT is an excellent technique before angiography and embolization in cases with acute gastrointestinal bleeding. Transcatheter embolization is an effective tool for ...

  2. Lateral topography for reducing effective dose in low-dose chest CT.

    Science.gov (United States)

    Bang, Dong-Ho; Lim, Daekeon; Hwang, Wi-Sub; Park, Seong-Hoon; Jeong, Ok-man; Kang, Kyung Wook; Kang, Hohyung

    2013-06-01

    The purposes of this study were to assess radiation exposure during low-dose chest CT by using lateral topography and to compare the lateral topographic findings with findings obtained with anteroposterior topography alone and anteroposterior and lateral topography combined. From November 2011 to February 2012, 210 male subjects were enrolled in the study. Age, weight, and height of the men were recorded. All subjects were placed into one of three subgroups based on the type of topographic image obtained: anteroposterior topography, lateral topography, and both anteroposterior and lateral topography. Imaging was performed with a 128-MDCT scanner. CT, except for topography, was the same for all subjects. A radiologist analyzed each image, recorded scan length, checked for any insufficiencies in the FOV, and calculated the effective radiation dose. One-way analysis of variance and multiple comparisons were used to compare the effective radiation exposure and scan length between groups. The mean scan length in the anteroposterior topography group was significantly greater than that of the lateral topography group and the combined anteroposterior and lateral topography group (p topography group (0.735 ± 0.033 mSv) was significantly lower than that for the anteroposterior topography group (0.763 ± 0.038 mSv) and the combined anteroposterior and lateral topography group (0.773 ± 0.038) (p < 0.001). Lateral topographic low-dose CT was associated with a lower effective radiation dose and scan length than either anteroposterior topographic low-dose chest CT or low-dose chest CT with both anteroposterior and lateral topograms.

  3. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT; Evaluation der Strahlendosis bei Polytrauma-CT-Untersuchungen eines 64-Zeilen-CT im Vergleich zur 4-Zeilen-CT

    Energy Technology Data Exchange (ETDEWEB)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U. [Ludwig-Maximilians-Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2012-05-15

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI{sub vol} values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 {+-} 2.5 vs. 11.4 {+-} 1.4, p < 0.001; 14.2 {+-} 3.7 vs. 16.1 {+-} 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 {+-} 201.1 vs. 849.8 {+-} 90.9, p < 0,001; 504.4 {+-} 134.4 vs. 471.5 {+-} 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 {+-} 35.8 vs. 155.5 {+-} 12.3 (p < 0.001), thorax 427.4 {+-} 44.5 vs. 388.3 {+-} 57.5 (p < 0.001), abdomen 520.3 {+-} 50.2 vs. 490.8 {+-} 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 {+-} 2.6 (4-row MDCT) and 24.1 {+-} 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  4. Dose-reduced 16-slice multidetector-row spiral computed tomography in children with bronchoscopically suspected vascular tracheal stenosis - initial results

    International Nuclear Information System (INIS)

    Honnef, D.; Wildberger, J.E.; Das, M.; Hohl, C.; Mahnken, A.; Guenther, R.W.; Staatz, G.; Schnoering, H.; Vazquez-Jimenez, J.

    2006-01-01

    Purpose: To evaluate the diagnostic accuracy of contrast-enhanced dose-reduced 16-slice multidetector-row CT (MDCT) in newborns and infants with fiberoptic bronchoscopically suspected vascular-induced tracheal stenosis. Materials and Methods: 12 children (4 days to 3 years, 1.2-13.5 kg body weight) were examined using i.v. contrast-enhanced 16-slice MDCT (SOMATOM Sensation 16, Forchheim, Germany) without breath-hold and under sedation (11/12). All MDCTs were performed with a dose reduction. The beam collimation was 16 x 0.75 mm, except in the case of one child. MPRs along the tracheal axis in the x-, y- and z-directions and volume-rendering-reconstructions (VRTs) were calculated based on a secondary raw data set in addition to conventional axial slices. 2 radiologists used a three-point grade scale to evaluate the image quality, motion, and contrast media artifacts as well as the usefulness of the 2D- and 3D-reconstructions for determining the diagnosis. Statistical analysis was performed on the basis of a Kappa test. Results: In all cases the cause of the fiberoptic bronchoscopically suspected tracheal stenosis was revealed: compression due to the brachiocephalic trunk (n=7), double aortic arch (n=2), lusorian artery (n=1), vascular compression of the left main bronchus (n=2). In 3 patients further thoracic anomalies, such as tracheobronchial (n=2), and vascular (n=2) and vertebral (n=1) anomalies were found. The attenuation in the anomalous vessels was 307±140 HU. The image noise was 9.8±1.9 HU. The mean dose reduction was 82.7±3.2% compared to a standard adult thoracic CT. All examinations were rated as diagnostically good (median 1, range 1, k=1). 3D images did not show any stair artifacts (median 2, range 1-2, k=1). The image noise was minor to moderate and hardly any motion artifacts were seen (median 1, range 1-2, k=0.8). Contrast media artifacts were rated zero to minor (median 1.5, range 1-2, k=0.676). MPRs (median 1, range 1, k=1) and VRTs (median 1

  5. Mushroom poisoning in children: liver MDCT findings in three cases

    International Nuclear Information System (INIS)

    Cakir, Banu; Kirbas, Ismail; Cevik, Belma; Teksam, Mehmet; Coskun, Mehmet

    2007-01-01

    Wild mushroom poisoning occurs quite frequently in Turkey, usually during late summer and autumn when climatic conditions favour fungal growth. We report the MDCT findings of the liver in three children after mushroom poisoning. In all three patients, precontrast MDCT findings showed diffuse reduction of hepatic attenuation compared with the spleen. Contrast-enhanced MDCT images showed homogeneous contrast enhancement of the liver. All three patients recovered after medical treatment. A follow-up precontrast MDCT examination was performed in one patient in whom the density of the liver parenchyma had returned to normal. (orig.)

  6. Multiphasic MDCT in small bowel volvulus

    International Nuclear Information System (INIS)

    Feng Shiting; Chan Tao; Sun Canhui; Li Ziping; Guo Huanyi; Yang Guangqi; Peng Zhenpeng; Meng Quanfei

    2010-01-01

    Objective: Evaluate the use of MDCT with 3D CT angiography (CTA) and CT portal venography (CTPV) reconstruction for the diagnosis of small bowel volvulus (SBV). Methods: Multiphasic MDCT findings in nine patients (seven males and two females, age range 2-70) with surgically proven SBV were retrospectively reviewed. Non-contrast and double phase contrast enhanced MDCT including 3D CTA and CTPV reconstruction were performed in all the patients. Two experienced abdominal radiologists evaluated the images and defined the location, direction and degree of SBV. Results: On axial MDCT images, all cases show segmental or global dilatation of small intestine. Other findings include circumferential bowel wall thickening in eight cases, halo appearance and hyperemia in seven cases, whirl sign in six cases, beak-like appearance in six cases, closed loops in six cases and ascites in one case. CTA/CTPV showed abnormal courses involving main trunks of superior mesenteric artery (SMA) and superior mesenteric vein (SMV) in seven cases, with or without distortion of their tributaries. Normal course of SMA but abnormal course of SMV was seen in the other two cases. Of all the nine cases, whirl sign was seen in six cases and barber's pole sign in five cases. Dilated SMV was observed in eight cases and abrupt termination of SMA was found in one case. Compared with surgical findings, the location, direction and degree of SBV were correctly estimated in all cases based on CTA/CTPV. Conclusion: Multiphasic MDCT with CTA/CTPV reconstruction can play an important role in the diagnosis of SBV. The location, direction and degree of SBV can all be defined preoperatively using this method.

  7. Multiphasic MDCT in small bowel volvulus

    Energy Technology Data Exchange (ETDEWEB)

    Feng Shiting, E-mail: fst1977@163.com [Department of Radiology, The First Affiliated Hospital, Sun Yat-Sen University, 58th The Second Zhongshan Road, Guangzhou 510080 (China); Chan Tao, E-mail: taochan@hku.hk [Department of Diagnostic Radiology, University of Hong Kong, Room 406, Block K, Queen Mary Hospital (Hong Kong); Sun Canhui, E-mail: canhuisun@sina.com [Department of Radiology, The First Affiliated Hospital, Sun Yat-Sen University, 58th The Second Zhongshan Road, Guangzhou 510080 (China); Li Ziping, E-mail: liziping163@tom.com [Department of Radiology, The First Affiliated Hospital, Sun Yat-Sen University, 58th The Second Zhongshan Road, Guangzhou 510080 (China); Guo Huanyi, E-mail: guohuanyi@163.com [Department of Radiology, The First Affiliated Hospital, Sun Yat-Sen University, 58th The Second Zhongshan Road, Guangzhou 510080 (China); Yang Guangqi, E-mail: shwy03@126.com [Department of Radiology, The First Affiliated Hospital, Sun Yat-Sen University, 58th The Second Zhongshan Road, Guangzhou 510080 (China); Peng Zhenpeng, E-mail: ppzhen@21cn.com [Department of Radiology, The First Affiliated Hospital, Sun Yat-Sen University, 58th The Second Zhongshan Road, Guangzhou 510080 (China); Meng Quanfei, E-mail: mzycoco@gmail.com [Department of Radiology, The First Affiliated Hospital, Sun Yat-Sen University, 58th The Second Zhongshan Road, Guangzhou 510080 (China)

    2010-11-15

    Objective: Evaluate the use of MDCT with 3D CT angiography (CTA) and CT portal venography (CTPV) reconstruction for the diagnosis of small bowel volvulus (SBV). Methods: Multiphasic MDCT findings in nine patients (seven males and two females, age range 2-70) with surgically proven SBV were retrospectively reviewed. Non-contrast and double phase contrast enhanced MDCT including 3D CTA and CTPV reconstruction were performed in all the patients. Two experienced abdominal radiologists evaluated the images and defined the location, direction and degree of SBV. Results: On axial MDCT images, all cases show segmental or global dilatation of small intestine. Other findings include circumferential bowel wall thickening in eight cases, halo appearance and hyperemia in seven cases, whirl sign in six cases, beak-like appearance in six cases, closed loops in six cases and ascites in one case. CTA/CTPV showed abnormal courses involving main trunks of superior mesenteric artery (SMA) and superior mesenteric vein (SMV) in seven cases, with or without distortion of their tributaries. Normal course of SMA but abnormal course of SMV was seen in the other two cases. Of all the nine cases, whirl sign was seen in six cases and barber's pole sign in five cases. Dilated SMV was observed in eight cases and abrupt termination of SMA was found in one case. Compared with surgical findings, the location, direction and degree of SBV were correctly estimated in all cases based on CTA/CTPV. Conclusion: Multiphasic MDCT with CTA/CTPV reconstruction can play an important role in the diagnosis of SBV. The location, direction and degree of SBV can all be defined preoperatively using this method.

  8. Analysis of absorbed dose in cervical spine scanning by computerized tomography using simulator objects; Análise de dose absorvida em varreduras de coluna cervical por tomografia computadorizada utlizando objetos simuladores

    Energy Technology Data Exchange (ETDEWEB)

    Lyra, Maria Henriqueta Freire

    2015-07-01

    The Computed tomography (CT) has become an important diagnostic tool after the continued development of Multidetector CT (MDCT), which allows faster acquisition of images with better quality than the previous technology. However, there is an increased radiation exposure, especially in examinations that require more than one acquisition, as dynamic exams and enhancement studies in order to discriminate low contrast soft tissue injury from normal tissue. Cervical spine MDCT examinations are used for diagnosis of soft tissue and vascular changes, fractures, dysplasia and other diseases with instability, which guide the patient treatment and rehabilitation. This study aims at checking the absorbed dose range in the thyroid and other organs during MDCT scan of cervical spine, with and without bismuth thyroid shield. In this experiment a cervical spine MDCT scan was performed on anthropomorphic phantoms, from the occipital to the first thoracic vertebra, using a 64 and a 16 – channel CT scanners. Thermoluminescent dosimeters were used to obtain the absorbed dose in thyroid, lenses, magnum foramen and breasts of the phantom. The results show that the thyroid received the highest dose, 60.0 mGy, in the female phantom, according to the incidence of the primary X-ray beam. The absorbed doses in these tests showed significant differences in the evaluated organs, p value < 0.005, except for the magnum foramen and breasts. With the bismuth thyroid shield applied on the female phantom, the doses in the thyroid and in the lenses were reduced by 27% and 52%, respectively. On the other hand, a reduction of 23.3% in the thyroid and increasing of 49.0% in the lens were measured on the male phantom. (author)

  9. Diagnostic accuracy of contemporary multidetector computed tomography (MDCT) for the detection of lumbar disc herniation

    Energy Technology Data Exchange (ETDEWEB)

    Notohamiprodjo, S.; Stahl, R.; Braunagel, M.; Kazmierczak, P.M.; Thierfelder, K.M.; Treitl, K.M.; Wirth, S. [University Hospital of Munich, LMU Munich, Institute for Clinical Radiology, Munich (Germany); Notohamiprodjo, M. [University Hospital Tuebingen, Eberhard Karls University Tuebingen, Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-08-15

    To evaluate the diagnostic accuracy of multidetector CT (MDCT) for detection of lumbar disc herniation with MRI as standard of reference. Patients with low back pain underwent indicated MDCT (128-row MDCT, helical pitch), 60 patients with iterative reconstruction (IR) and 67 patients with filtered back projection (FBP). Lumbar spine MRI (1.5 T) was performed within 1 month. Signal-to-noise ratios (SNR) of cerebrospinal fluid (CSF), annulus fibrosus (AF) and the spinal cord (SC) were determined for all modalities. Two readers independently rated image quality (IQ), diagnostic confidence and accuracy in the diagnosis of lumbar disc herniation using MRI as standard of reference. Inter-reader correlation was assessed with weighted κ. Sensitivity, specificity, precision and accuracy of MDCT for disc protrusion were 98.8%, 96.5%, 97.1%, 97.8% (disc level), 97.7%, 92.9%, 98.6%, 96.9% (patient level). SNR of IR was significantly higher than FBP. IQ was significantly better in IR owing to visually reduced noise and improved delineation of the discs. κ (>0.90) was excellent for both algorithms. MDCT of the lumbar spine yields high diagnostic accuracy for detection of lumbar disc herniation. IR improves image quality so that the provided diagnostic accuracy is principally equivalent to MRI. (orig.)

  10. Analysis of absorbed dose in cervical spine scanning by computerized tomography using simulator objects

    International Nuclear Information System (INIS)

    Lyra, Maria Henriqueta Freire

    2015-01-01

    The Computed tomography (CT) has become an important diagnostic tool after the continued development of Multidetector CT (MDCT), which allows faster acquisition of images with better quality than the previous technology. However, there is an increased radiation exposure, especially in examinations that require more than one acquisition, as dynamic exams and enhancement studies in order to discriminate low contrast soft tissue injury from normal tissue. Cervical spine MDCT examinations are used for diagnosis of soft tissue and vascular changes, fractures, dysplasia and other diseases with instability, which guide the patient treatment and rehabilitation. This study aims at checking the absorbed dose range in the thyroid and other organs during MDCT scan of cervical spine, with and without bismuth thyroid shield. In this experiment a cervical spine MDCT scan was performed on anthropomorphic phantoms, from the occipital to the first thoracic vertebra, using a 64 and a 16 – channel CT scanners. Thermoluminescent dosimeters were used to obtain the absorbed dose in thyroid, lenses, magnum foramen and breasts of the phantom. The results show that the thyroid received the highest dose, 60.0 mGy, in the female phantom, according to the incidence of the primary X-ray beam. The absorbed doses in these tests showed significant differences in the evaluated organs, p value < 0.005, except for the magnum foramen and breasts. With the bismuth thyroid shield applied on the female phantom, the doses in the thyroid and in the lenses were reduced by 27% and 52%, respectively. On the other hand, a reduction of 23.3% in the thyroid and increasing of 49.0% in the lens were measured on the male phantom. (author)

  11. Performance of cone-beam computed tomography and multidetector computed tomography in diagnostic imaging of the midface: A comparative study on Phantom and cadaver head scans

    Energy Technology Data Exchange (ETDEWEB)

    Veldhoen, Simon [University Medical Center Hamburg, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); University Hospital Wuerzburg, Department of Diagnostic and Interventional Radiology, Wuerzburg (Germany); Schoellchen, Maximilian; Hanken, H.; Precht, C.; Heiland, M. [University Medical Center Hamburg, Department of Oral- and Maxillofacial Surgery, Hamburg (Germany); Henes, F.O.; Adam, G.; Regier, M. [University Medical Center Hamburg, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Schoen, G. [University Medical Center Hamburg, Department of Medical Biometry and Epidemiology, Hamburg (Germany); Nagel, H.D. [Science and Technology for Radiology, Buchholz (Germany); Schumacher, U. [University Medical Center Hamburg, Institute of Anatomy, Hamburg (Germany)

    2017-02-15

    To compare multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) regarding radiation, resolution, image noise, and image quality. CBCT and 256-MDCT were compared based on three scan protocols: Standard-dose (∼24 mGy), reduced-dose (∼9 mGy), and low-dose (∼4 mGy). MDCT images were acquired in standard- and high-resolution mode (HR-MDCT) and reconstructed using filtered back projection (FBP) and iterative reconstruction (IR). Spatial resolution in linepairs (lp) and objective image noise (OIN) were assessed using dedicated phantoms. Image quality was assessed in scans of 25 cadaver heads using a Likert scale. OIN was markedly higher in FBP-MDCT when compared to CBCT. IR lowered the OIN to comparable values in standard-mode MDCT only. CBCT provided a resolution of 13 lp/cm at standard-dose and 11 lp/cm at reduced-dose vs. 11 lp/cm and 10 lp/cm in HR-MDCT. Resolution of 10 lp/cm was observed for both devices using low-dose settings. Quality scores of MDCT and CBCT did not differ at standard-dose (CBCT, 3.4; MDCT, 3.3-3.5; p > 0.05). Using reduced- and low-dose protocols, CBCT was superior (reduced-dose, 3.2 vs. 2.8; low dose, 3.0 vs. 2.3; p < 0.001). Using the low-dose protocol, the assessed CBCT provided better objective and subjective image quality and equality in resolution. Similar image quality, but better resolution using CBCT was observed at higher exposure settings. (orig.)

  12. MDCT diagnosis of penetrating diaphragm injury

    Energy Technology Data Exchange (ETDEWEB)

    Bodanapally, Uttam K.; Shanmuganathan, Kathirkamanathan; Mirvis, Stuart E.; Sliker, Clint W.; Fleiter, Thorsten R.; Sarada, Kamal; Miller, Lisa A. [University of Maryland School of Medicine, Department of Diagnostic Radiology, Baltimore, MD (United States); Stein, Deborah M. [University of Maryland, Department of Surgery, Shock Trauma Center, Baltimore, MD (United States); Alexander, Melvin [National Study Center for Trauma and Emergency Medical Systems, Baltimore, MD (United States)

    2009-08-15

    The purpose of the study was to determine the diagnostic sensitivity and specificity of multidetector CT (MDCT) in detection of diaphragmatic injury following penetrating trauma. Chest and abdominal CT examinations performed preoperatively in 136 patients after penetrating trauma to the torso with injury trajectory in close proximity to the diaphragm were reviewed by radiologists unaware of surgical findings. Signs associated with diaphragmatic injuries in penetrating trauma were noted. These signs were correlated with surgical diagnoses, and their sensitivity and specificity in assisting the diagnosis were calculated. CT confirmed diaphragmatic injury in 41 of 47 injuries (sensitivity, 87.2%), and an intact diaphragm in 71 of 98 patients (specificity, 72.4%). The overall accuracy of MDCT was 77%. The most accurate sign helping the diagnosis was contiguous injury on either side of the diaphragm in single-entry penetrating trauma (sensitivity, 88%; specificity, 82%). Thus MDCT has high sensitivity and good specificity in detecting penetrating diaphragmatic injuries. (orig.)

  13. MDCT diagnosis of penetrating diaphragm injury

    International Nuclear Information System (INIS)

    Bodanapally, Uttam K.; Shanmuganathan, Kathirkamanathan; Mirvis, Stuart E.; Sliker, Clint W.; Fleiter, Thorsten R.; Sarada, Kamal; Miller, Lisa A.; Stein, Deborah M.; Alexander, Melvin

    2009-01-01

    The purpose of the study was to determine the diagnostic sensitivity and specificity of multidetector CT (MDCT) in detection of diaphragmatic injury following penetrating trauma. Chest and abdominal CT examinations performed preoperatively in 136 patients after penetrating trauma to the torso with injury trajectory in close proximity to the diaphragm were reviewed by radiologists unaware of surgical findings. Signs associated with diaphragmatic injuries in penetrating trauma were noted. These signs were correlated with surgical diagnoses, and their sensitivity and specificity in assisting the diagnosis were calculated. CT confirmed diaphragmatic injury in 41 of 47 injuries (sensitivity, 87.2%), and an intact diaphragm in 71 of 98 patients (specificity, 72.4%). The overall accuracy of MDCT was 77%. The most accurate sign helping the diagnosis was contiguous injury on either side of the diaphragm in single-entry penetrating trauma (sensitivity, 88%; specificity, 82%). Thus MDCT has high sensitivity and good specificity in detecting penetrating diaphragmatic injuries. (orig.)

  14. Quantitative assessment of cross-sectional area of small pulmonary vessels in patients with COPD using inspiratory and expiratory MDCT

    International Nuclear Information System (INIS)

    Matsuura, Yukiko; Kawata, Naoko; Yanagawa, Noriyuki; Sugiura, Toshihiko; Sakurai, Yoriko; Sato, Misuzu; Iesato, Ken; Terada, Jiro; Sakao, Seiichiro; Tada, Yuji; Tanabe, Nobuhiro; Suzuki, Yoichi; Tatsumi, Koichiro

    2013-01-01

    Objectives: Structural and functional changes in pulmonary vessels are prevalent at the initial stages of chronic obstructive pulmonary disease (COPD). These vascular alterations can be assessed using cross-sectional area (CSA) of small pulmonary vessels. However, neither in non-COPD smokers nor in COPD patients it has been defined whether the structural changes of pulmonary vessels detected by paired inspiratory and expiratory CT scans are associated with emphysematous changes. We quantified the CSA and low attenuation area (LAA) and evaluated the changes in these parameters in the inspiratory and expiratory phases. Materials and methods: Fifty consecutive non-COPD smokers and COPD patients were subjected to multi detector-row CT and the percentage of vessels with a CSA less than 5 mm 2 as well as the percentage LAA for total lung area (%CSA < 5, %LAA, respectively) were calculated. Results: The %CSA < 5 correlated negatively with %LAA. The %CSA < 5 was lower in COPD patients with emphysema as compared with non-COPD smokers and COPD patients with or without mild emphysema. In addition, the %CSA < 5 was lower in the no/mild emphysema subgroup as compared with non-COPD smokers. The respiratory phase change of %CSA < 5 in COPD patients was greater than that in non-COPD smokers. Conclusion: The percentage of small pulmonary vessels decreased as emphysematous changes increase, and this decrease was observed even in patients with no/mild emphysema. Furthermore, respiratory phase changes in CSA were higher in COPD patients than in non-COPD smokers

  15. Low contrast detectability and spatial resolution with model-based iterative reconstructions of MDCT images: a phantom and cadaveric study

    Energy Technology Data Exchange (ETDEWEB)

    Millon, Domitille; Coche, Emmanuel E. [Universite Catholique de Louvain, Department of Radiology and Medical Imaging, Cliniques Universitaires Saint Luc, Brussels (Belgium); Vlassenbroek, Alain [Philips Healthcare, Brussels (Belgium); Maanen, Aline G. van; Cambier, Samantha E. [Universite Catholique de Louvain, Statistics Unit, King Albert II Cancer Institute, Brussels (Belgium)

    2017-03-15

    To compare image quality [low contrast (LC) detectability, noise, contrast-to-noise (CNR) and spatial resolution (SR)] of MDCT images reconstructed with an iterative reconstruction (IR) algorithm and a filtered back projection (FBP) algorithm. The experimental study was performed on a 256-slice MDCT. LC detectability, noise, CNR and SR were measured on a Catphan phantom scanned with decreasing doses (48.8 down to 0.7 mGy) and parameters typical of a chest CT examination. Images were reconstructed with FBP and a model-based IR algorithm. Additionally, human chest cadavers were scanned and reconstructed using the same technical parameters. Images were analyzed to illustrate the phantom results. LC detectability and noise were statistically significantly different between the techniques, supporting model-based IR algorithm (p < 0.0001). At low doses, the noise in FBP images only enabled SR measurements of high contrast objects. The superior CNR of model-based IR algorithm enabled lower dose measurements, which showed that SR was dose and contrast dependent. Cadaver images reconstructed with model-based IR illustrated that visibility and delineation of anatomical structure edges could be deteriorated at low doses. Model-based IR improved LC detectability and enabled dose reduction. At low dose, SR became dose and contrast dependent. (orig.)

  16. Concordance of coronary artery calcium estimates between MDCT and electron beam tomography.

    Science.gov (United States)

    Daniell, Anthony L; Wong, Nathan D; Friedman, John D; Ben-Yosef, Nachum; Miranda-Peats, Romalisa; Hayes, Sean W; Kang, Xingping; Sciammarella, Maria G; de Yang, Ling; Germano, Guido; Berman, Daniel S

    2005-12-01

    The objective of our study was to compare MDCT with electron beam tomography (EBT) for the quantification of coronary artery calcification (CAC). Sixty-eight patients underwent both MDCT and EBT within 2 months for the quantification of CAC. The images were scored in a blinded fashion and independently by two observers with a minimum of 7 days between the interpretations of images obtained from one scanner type to the other. Presence versus absence of CAC was discordant by EBT versus MDCT in 6% (n = 4) of the cases by observer 1, with one of these cases also discordant by observer 2. All cases except one (aortic calcium misidentified as CAC) were among those with a mean Agatston score of less than 5 present on EBT but absent on MDCT. EBT and MDCT scores correlated well (r = 0.98-0.99). The relative median variability between EBT and MDCT for the Agatston score was 24% for observer 1 and 27% for observer 2 and was 18% and 14%, respectively, for volume score (average for both observers: 27% for Agatston score and 16% for volume score). Scores were higher for EBT than MDCT in approximately half of the cases, with little systematic difference between the two (median EBT-MDCT difference: Agatston score, -0.55; volume score, 3.4 mm3). The absolute median difference averaged for the two observers was 28.75 for the Agatston score and 15.4 mm3 for the volume score. Differences in CAC measurements using EBT and MDCT are similar to interscan differences in CAC measurements previously reported for EBT or for other MDCT scanners individually.

  17. MDCT for computerized volumetry of pneumothoraces in pediatric patients.

    Science.gov (United States)

    Cai, Wenli; Lee, Edward Y; Vij, Abhinav; Mahmood, Soran A; Yoshida, Hiroyuki

    2011-03-01

    Our purpose in this study was to develop an automated computer-aided volumetry (CAV) scheme for quantifying pneumothorax in multidetector computed tomography (MDCT) images for pediatric patients and to investigate the imaging parameters that may affect its accuracy. Fifty-eight consecutive pediatric patients (mean age 12 ± 6 years) with pneumothorax who underwent MDCT for evaluation were collected retrospectively for this study. All cases were imaged by a 16- or 64-MDCT scanner with weight-based kilovoltage, low-dose tube current, 1.0-1.5 pitch, 0.6-5.0 mm slice thickness, and a B70f (sharp) or B31f (soft) reconstruction kernel. Sixty-three pneumothoraces ≥1 mL were visually identified in the left (n = 30) and right (n = 33) lungs. Each identified pneumothorax was contoured manually on an Amira workstation V4.1.1 (Mercury Computer Systems, Chelmsford, MA) by two radiologists in consensus. The computerized volumes of the pneumothoraces were determined by application of our CAV scheme. The accuracy of our automated CAV scheme was evaluated by comparison between computerized volumetry and manual volumetry, for the total volume of pneumothoraces in the left and right lungs. The mean difference between the computerized volumetry and the manual volumetry for all 63 pneumothoraces ≥1 mL was 8.2%. For pneumothoraces ≥10 mL, ≥50 mL, and ≥200 mL, the mean differences were 7.7% (n = 57), 7.3% (n = 33), and 6.4% (n = 13), respectively. The correlation coefficient was 0.99 between the computerized volume and the manual volume of pneumothoraces. Bland-Altman analysis showed that computerized volumetry has a mean difference of -5.1% compared to manual volumetry. For all pneumothoraces ≥10 mL, the mean differences for slice thickness ≤1.25 mm, = 1.5 mm, and = 5.0 mm were 6.1% (n = 28), 3.5% (n = 10), and 12.2% (n = 19), respectively. For the two reconstruction kernels, B70f and B31f, the mean differences were 6.3% (n = 42, B70f) and 11.7% (n = 15, B31f

  18. Dual energy MDCT assessment of renal lesions: an overview

    International Nuclear Information System (INIS)

    Mileto, Achille; Marin, Daniele; Nelson, Rendon C.; Boll, Daniel T.; Ascenti, Giorgio

    2014-01-01

    With the expansion of cross-sectional imaging, the number of renal lesions that are incidentally discovered has increased. Multidetector CT (MDCT) is the investigation of choice for characterising and staging renal lesions. Although a definitive diagnosis can be confidently posed for most of them, a number of renal lesions remain indeterminate following MDCT. Further imaging tests are therefore needed, with subsequent increase of healthcare costs, radiation exposure, and patient anxiety. By addressing most of the issues with conventional MDCT imaging, dual-energy MDCT can improve the diagnosis of renal lesions and, potentially, may represent a paradigm shift from a merely attenuation-based to a material-specific spectral imaging investigation. The purpose of this review is to provide an overview of current clinical applications of dual-energy CT in the evaluation of renal lesions. Key Points. (orig.)

  19. Dual energy MDCT assessment of renal lesions: an overview

    Energy Technology Data Exchange (ETDEWEB)

    Mileto, Achille [Duke University Medical Center, Department of Radiology, Durham, NC (United States); University of Messina, Department of Biomedical Sciences and Morphologic and Functional Imaging, Policlinico ' ' G. Martino' ' , Messina (Italy); Marin, Daniele; Nelson, Rendon C.; Boll, Daniel T. [Duke University Medical Center, Department of Radiology, Durham, NC (United States); Ascenti, Giorgio [University of Messina, Department of Biomedical Sciences and Morphologic and Functional Imaging, Policlinico ' ' G. Martino' ' , Messina (Italy)

    2014-02-15

    With the expansion of cross-sectional imaging, the number of renal lesions that are incidentally discovered has increased. Multidetector CT (MDCT) is the investigation of choice for characterising and staging renal lesions. Although a definitive diagnosis can be confidently posed for most of them, a number of renal lesions remain indeterminate following MDCT. Further imaging tests are therefore needed, with subsequent increase of healthcare costs, radiation exposure, and patient anxiety. By addressing most of the issues with conventional MDCT imaging, dual-energy MDCT can improve the diagnosis of renal lesions and, potentially, may represent a paradigm shift from a merely attenuation-based to a material-specific spectral imaging investigation. The purpose of this review is to provide an overview of current clinical applications of dual-energy CT in the evaluation of renal lesions. Key Points. (orig.)

  20. Superwideband Bandwidth Extension Using Normalized MDCT Coefficients for Scalable Speech and Audio Coding

    Directory of Open Access Journals (Sweden)

    Young Han Lee

    2013-01-01

    Full Text Available A bandwidth extension (BWE algorithm from wideband to superwideband (SWB is proposed for a scalable speech/audio codec that uses modified discrete cosine transform (MDCT coefficients as spectral parameters. The superwideband is first split into several subbands that are represented as gain parameters and normalized MDCT coefficients in the proposed BWE algorithm. We then estimate normalized MDCT coefficients of the wideband to be fetched for the superwideband and quantize the fetch indices. After that, we quantize gain parameters by using relative ratios between adjacent subbands. The proposed BWE algorithm is embedded into a standard superwideband codec, the SWB extension of G.729.1 Annex E, and its bitrate and quality are compared with those of the BWE algorithm already employed in the standard superwideband codec. It is shown from the comparison that the proposed BWE algorithm relatively reduces the bitrate by around 19% with better quality, compared to the BWE algorithm in the SWB extension of G.729.1 Annex E.

  1. Radiation dose of digital tomosynthesis for sinonasal examination: comparison with multi-detector CT.

    Science.gov (United States)

    Machida, Haruhiko; Yuhara, Toshiyuki; Tamura, Mieko; Numano, Tomokazu; Abe, Shinji; Sabol, John M; Suzuki, Shigeru; Ueno, Eiko

    2012-06-01

    Using an anthropomorphic phantom, we have investigated the feasibility of digital tomosynthesis (DT) of flat-panel detector (FPD) radiography to reduce radiation dose for sinonasal examination compared to multi-detector computed tomography (MDCT). A female Rando phantom was scanned covering frontal to maxillary sinus using the clinically routine protocol by both 64-detector CT (120 kV, 200 mAs, and 1.375-pitch) and DT radiography (80 kV, 1.0 mAs per projection, 60 projections, 40° sweep, and posterior-anterior projections). Glass dosimeters were used to measure the radiation dose to internal organs including the thyroid gland, brain, submandibular gland, and the surface dose at various sites including the eyes during those scans. We compared the radiation dose to those anatomies between both modalities. In DT radiography, the doses of the thyroid gland, brain, submandibular gland, skin, and eyes were 230 ± 90 μGy, 1770 ± 560 μGy, 1400 ± 80 μGy, 1160 ± 2100 μGy, and 112 ± 6 μGy, respectively. These doses were reduced to approximately 1/5, 1/8, 1/12, 1/17, and 1/290 of the respective MDCT dose. For sinonasal examinations, DT radiography enables dramatic reduction in radiation exposure and dose to the head and neck region, particularly to the lens of the eye. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  2. Multidetector CT in children: current concepts and dose reduction strategies

    Energy Technology Data Exchange (ETDEWEB)

    Nievelstein, Rutger A.J.; Dam, Ingrid M. van [University Medical Centre Utrecht, Department of Pediatric Radiology, Wilhelmina Children' s Hospital, E01.132, P.O. Box 85500, Utrecht (Netherlands); Molen, Aart J. van der [Leiden University Medical Centre, Department of Radiology, C-2S, Leiden (Netherlands)

    2010-08-15

    The recent technical development of multidetector CT (MDCT) has contributed to a substantial increase in its diagnostic applications and accuracy in children. A major drawback of MDCT is the use of ionising radiation with the risk of inducing secondary cancer. Therefore, justification and optimisation of paediatric MDCT is of great importance in order to minimise these risks (''as low as reasonably achievable'' principle). This review will focus on all technical and non-technical aspects relevant for paediatric MDCT optimisation and includes guidelines for radiation dose level-based CT protocols. (orig.)

  3. Multidetector CT in children: current concepts and dose reduction strategies

    International Nuclear Information System (INIS)

    Nievelstein, Rutger A.J.; Dam, Ingrid M. van; Molen, Aart J. van der

    2010-01-01

    The recent technical development of multidetector CT (MDCT) has contributed to a substantial increase in its diagnostic applications and accuracy in children. A major drawback of MDCT is the use of ionising radiation with the risk of inducing secondary cancer. Therefore, justification and optimisation of paediatric MDCT is of great importance in order to minimise these risks (''as low as reasonably achievable'' principle). This review will focus on all technical and non-technical aspects relevant for paediatric MDCT optimisation and includes guidelines for radiation dose level-based CT protocols. (orig.)

  4. Effect of radiation dose and iterative reconstruction on lung lesion conspicuity at MDCT: Does one size fit all?

    Energy Technology Data Exchange (ETDEWEB)

    Botelho, Marcos Paulo Ferreira; Agrawal, Rishi, E-mail: rishi.agrawal@northwestern.edu; Gonzalez-Guindalini, Fernanda Dias; Hart, Eric M.; Patel, Suresh K.; Töre, Hüseyin Gürkan; Yaghmai, Vahid

    2013-11-01

    Objective: To evaluate the effect of different acquisition parameters and reconstruction algorithms in lung lesions conspicuity in chest MDCT. Methods: An anthropomorphic chest phantom containing 6 models of lung disease (ground glass opacity, bronchial polyp, solid nodule, ground glass nodule, emphysema and tree-in-bud) was scanned using 80, 100 and 120 kVp, with fixed mAs ranging from 10 to 110. The scans were reconstructed using filtered back projection (FBP) and iterative reconstruction (IR) algorithms. Three blinded thoracic radiologists reviewed the images and scored lesions conspicuity and overall image quality. Image noise and radiation dose parameters were recorded. Results: All acquisitions with 120 kVp received a score of 3 (acceptable) or higher for overall image quality. There was no significant difference between IR and FBP within each setting for overall image quality (p > 0.05), even though image noise was significantly lower using IR (p < 0.0001). When comparing specific lower radiation acquisition parameters 100 kVp/10 mAs [Effective Dose (ED): 0.238 mSv] vs 120 kVp/10 mAs (ED: 0.406 mSv) vs 80 kVp/40 mAs (ED: 0.434 mSv), we observed significant difference in lesions conspicuity (p < 0.02), as well as significant difference in overall image quality, independent of the reconstruction algorithm (p < 0.02), with higher scores on the 120 kV/10 mAs setting. Tree-in-bud pattern, ground glass nodule and ground glass opacity required lower radiation doses to get a diagnostic score using IR when compared to FBP. Conclusion: Designing protocols for specific lung pathologies using lower dose acquisition parameters is feasible, and by applying iterative reconstruction, radiologists may have better diagnostic confidence to evaluate some lesions in very low dose settings, preserving acceptable image quality.

  5. Quantitative assessment of cross-sectional area of small pulmonary vessels in patients with COPD using inspiratory and expiratory MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Matsuura, Yukiko, E-mail: matsuyuki_future@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Kawata, Naoko, E-mail: chumito_03@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Yanagawa, Noriyuki, E-mail: yanagawa@ho.chiba-u.ac.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sugiura, Toshihiko, E-mail: sugiura@js3.so-net.ne.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sakurai, Yoriko, E-mail: yoliri@nifty.com [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sato, Misuzu, E-mail: mis_misuzu@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Iesato, Ken, E-mail: iesato_k@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Terada, Jiro, E-mail: jirotera@chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sakao, Seiichiro, E-mail: sakao@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Tada, Yuji, E-mail: ytada@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Tanabe, Nobuhiro, E-mail: ntanabe@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Suzuki, Yoichi, E-mail: ysuzuki@faculty.chiba-u.jp [Department of public Health, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Tatsumi, Koichiro, E-mail: tatsumi@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan)

    2013-10-01

    Objectives: Structural and functional changes in pulmonary vessels are prevalent at the initial stages of chronic obstructive pulmonary disease (COPD). These vascular alterations can be assessed using cross-sectional area (CSA) of small pulmonary vessels. However, neither in non-COPD smokers nor in COPD patients it has been defined whether the structural changes of pulmonary vessels detected by paired inspiratory and expiratory CT scans are associated with emphysematous changes. We quantified the CSA and low attenuation area (LAA) and evaluated the changes in these parameters in the inspiratory and expiratory phases. Materials and methods: Fifty consecutive non-COPD smokers and COPD patients were subjected to multi detector-row CT and the percentage of vessels with a CSA less than 5 mm{sup 2} as well as the percentage LAA for total lung area (%CSA < 5, %LAA, respectively) were calculated. Results: The %CSA < 5 correlated negatively with %LAA. The %CSA < 5 was lower in COPD patients with emphysema as compared with non-COPD smokers and COPD patients with or without mild emphysema. In addition, the %CSA < 5 was lower in the no/mild emphysema subgroup as compared with non-COPD smokers. The respiratory phase change of %CSA < 5 in COPD patients was greater than that in non-COPD smokers. Conclusion: The percentage of small pulmonary vessels decreased as emphysematous changes increase, and this decrease was observed even in patients with no/mild emphysema. Furthermore, respiratory phase changes in CSA were higher in COPD patients than in non-COPD smokers.

  6. Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists.

    Science.gov (United States)

    Neubauer, Jakob; Benndorf, Matthias; Reidelbach, Carolin; Krauß, Tobias; Lampert, Florian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Fiebich, Martin; Goerke, Sebastian M

    2016-01-01

    To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = radiography (P radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run.

  7. Multi-detector CT (MDCT in bowel and mesenteric injury

    Directory of Open Access Journals (Sweden)

    Vajjalla Ravikumar

    2013-04-01

    Full Text Available Objectives: To evaluate multi-detector CT (MDCT findings in bowel and mesenteric injury due to blunt abdominal trauma.Method: Retrospective evaluation of MDCT scan reports of patients admitted in Hamad Medical Corporation, Doha, Qatar with bowel and mesenteric injury during the period of January 2005 to April 2008.Results: MDCT, without using oral contrast, clearly demonstrated various specific and less specific findings of bowel and mesenteric injury.Conclusion: Multi-detector CT is an excellent diagnostic modality in bowel and mesenteric injury. Routine administration of oral contrast agent is not mandatory for initial evaluation of these patients.

  8. MDCT of renal and mesenteric vessels

    Energy Technology Data Exchange (ETDEWEB)

    Fleischmann, D. [Dept. of Radiology, Stanford Univ. Medical Center, Stanford, CA (United States)

    2003-12-01

    Computed tomography angiography (CTA) with multiple detector-row CT (MDCT) has evolved into an established technique for non-invasive imaging of renal and mesenteric vessels. With adequate selection of acquisition parameters (thin collimation) high spatial-resolution volumetric data sets for subsequent 2D and 3D reformation can be acquired. Contrast medium (CM) injection parameters need to be adjusted to the acquisition speed of the scanners. Whereas fast acquisitions allow a reduction of total CM volume in the setting of CTA, this is not the case when CTA is combined with a second-phase abdominal MDCT acquisition for parenchymal (e.g., hepatic) imaging. Renal CTA is an accurate and reliable test for visualizing vascular anatomy and renal artery stenosis, and therefore a viable alternative to MRA in the assessment of patients with renovascular hypertension and in potential living related renal donors. CTA, combined with abdominal/parenchymal MDCT is a first-line diagnostic test in patients with suspected abdominal vascular emergencies, such as acute mesenteric ischemia, and an excellent tool to assess a wide variety of vascular abnormalities of the abdominal viscera. (orig.)

  9. MDCT of renal and mesenteric vessels

    International Nuclear Information System (INIS)

    Fleischmann, D.

    2003-01-01

    Computed tomography angiography (CTA) with multiple detector-row CT (MDCT) has evolved into an established technique for non-invasive imaging of renal and mesenteric vessels. With adequate selection of acquisition parameters (thin collimation) high spatial-resolution volumetric data sets for subsequent 2D and 3D reformation can be acquired. Contrast medium (CM) injection parameters need to be adjusted to the acquisition speed of the scanners. Whereas fast acquisitions allow a reduction of total CM volume in the setting of CTA, this is not the case when CTA is combined with a second-phase abdominal MDCT acquisition for parenchymal (e.g., hepatic) imaging. Renal CTA is an accurate and reliable test for visualizing vascular anatomy and renal artery stenosis, and therefore a viable alternative to MRA in the assessment of patients with renovascular hypertension and in potential living related renal donors. CTA, combined with abdominal/parenchymal MDCT is a first-line diagnostic test in patients with suspected abdominal vascular emergencies, such as acute mesenteric ischemia, and an excellent tool to assess a wide variety of vascular abnormalities of the abdominal viscera. (orig.)

  10. Comparison of changes in tidal volume associated with expiratory rib cage compression and expiratory abdominal compression in patients on prolonged mechanical ventilation.

    Science.gov (United States)

    Morino, Akira; Shida, Masahiro; Tanaka, Masashi; Sato, Kimihiro; Seko, Toshiaki; Ito, Shunsuke; Ogawa, Shunichi; Takahashi, Naoaki

    2015-07-01

    [Purpose] This study was designed to compare and clarify the relationship between expiratory rib cage compression and expiratory abdominal compression in patients on prolonged mechanical ventilation, with a focus on tidal volume. [Subjects and Methods] The subjects were 18 patients on prolonged mechanical ventilation, who had undergone tracheostomy. Each patient received expiratory rib cage compression and expiratory abdominal compression; the order of implementation was randomized. Subjects were positioned in a 30° lateral recumbent position, and a 2-kgf compression was applied. For expiratory rib cage compression, the rib cage was compressed unilaterally; for expiratory abdominal compression, the area directly above the navel was compressed. Tidal volume values were the actual measured values divided by body weight. [Results] Tidal volume values were as follows: at rest, 7.2 ± 1.7 mL/kg; during expiratory rib cage compression, 8.3 ± 2.1 mL/kg; during expiratory abdominal compression, 9.1 ± 2.2 mL/kg. There was a significant difference between the tidal volume during expiratory abdominal compression and that at rest. The tidal volume in expiratory rib cage compression was strongly correlated with that in expiratory abdominal compression. [Conclusion] These results indicate that expiratory abdominal compression may be an effective alternative to the manual breathing assist procedure.

  11. MDCT imaging of calcinosis in systemic sclerosis

    International Nuclear Information System (INIS)

    Freire, V.; Becce, F.; Feydy, A.; Guérini, H.; Campagna, R.; Allanore, Y.; Drapé, J.-L.

    2013-01-01

    Calcinosis is a typical feature of systemic sclerosis (SSc) and can be found in many different tissues including the superficial soft tissues, periarticular structures, muscles, and tendons. It can also provoke erosive changes on bones. Investigation is conducted most often with plain radiographs. However, when a more detailed assessment is necessary, multidetector computed tomography (MDCT) is helpful owing to its multiplanar reformat (MPR) ability. The purpose of this review is to provide an overview of the various appearances of calcinosis in SSc patients as visualized at MDCT

  12. Vertebral lesion distribution in multiple myeloma - assessed by reduced-dose whole-body MDCT

    International Nuclear Information System (INIS)

    Bier, Georg; Kloth, Christopher; Schabel, Christoph; Bongers, Malte; Nikolaou, Konstantin; Horger, Marius

    2016-01-01

    To observe the distribution and potential distribution patterns of osteolytic and sclerotic vertebral involvement in a representative collective of multiple myeloma patients. A total of 66 consecutive patients with a diagnosis of multiple myeloma at initial diagnosis or during follow-up were examined by multidetector reduced-dose computed tomography to evaluate the distribution of bone lesions along the spine with focus on size, location, and lesion character. Confirmation of diagnosis was performed by comparison to follow-up computed tomography or magnetic resonance tomography. If >50 % of all detected malignant lesions occurred in one spinal segment, the distribution pattern was called cervical, thoracic, lumbar, or sacral, otherwise a ''mixed'' pattern was classified. Of a total number of 933 osseous spine lesions, 632 (67.7 %) were classified as malignant (98.9 % of them osteolytic) and 293 (31.5 %) as benign. The distribution pattern analysis yielded two patients (3.8 %) with a cervical, 26 (50 %) with a thoracic, 4 (7.7 %) with a lumbar, one (1.9 %) with a sacral pattern, and 19 cases (36.6 %) showed a mixed distribution pattern. Segment-wise, the mean lesion size was 6.52 ± 2.76 mm (cervical), 8.97 ± 5.43 mm (thoracic), 11.97 ± 7.11 mm (lumbar), and 17.5 ± 16.465 (sacral), whilst, related to the vertebra size, the lesion/vertebra size ratio is decreasing through the whole spine beginning from the top. Multiple myeloma bone lesions occur preferably and are larger in the thoracic and lumbar spine. Moreover, a specific distribution pattern is present in about 60 %. (orig.)

  13. Vertebral lesion distribution in multiple myeloma - assessed by reduced-dose whole-body MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Bier, Georg; Kloth, Christopher; Schabel, Christoph; Bongers, Malte; Nikolaou, Konstantin; Horger, Marius [Eberhard-Karls-University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2016-01-15

    To observe the distribution and potential distribution patterns of osteolytic and sclerotic vertebral involvement in a representative collective of multiple myeloma patients. A total of 66 consecutive patients with a diagnosis of multiple myeloma at initial diagnosis or during follow-up were examined by multidetector reduced-dose computed tomography to evaluate the distribution of bone lesions along the spine with focus on size, location, and lesion character. Confirmation of diagnosis was performed by comparison to follow-up computed tomography or magnetic resonance tomography. If >50 % of all detected malignant lesions occurred in one spinal segment, the distribution pattern was called cervical, thoracic, lumbar, or sacral, otherwise a ''mixed'' pattern was classified. Of a total number of 933 osseous spine lesions, 632 (67.7 %) were classified as malignant (98.9 % of them osteolytic) and 293 (31.5 %) as benign. The distribution pattern analysis yielded two patients (3.8 %) with a cervical, 26 (50 %) with a thoracic, 4 (7.7 %) with a lumbar, one (1.9 %) with a sacral pattern, and 19 cases (36.6 %) showed a mixed distribution pattern. Segment-wise, the mean lesion size was 6.52 ± 2.76 mm (cervical), 8.97 ± 5.43 mm (thoracic), 11.97 ± 7.11 mm (lumbar), and 17.5 ± 16.465 (sacral), whilst, related to the vertebra size, the lesion/vertebra size ratio is decreasing through the whole spine beginning from the top. Multiple myeloma bone lesions occur preferably and are larger in the thoracic and lumbar spine. Moreover, a specific distribution pattern is present in about 60 %. (orig.)

  14. Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects

    International Nuclear Information System (INIS)

    Huang, Ambrose J.; Chang, Connie Y.; Palmer, William E.; Thomas, Bijoy J.; MacMahon, Peter J.

    2015-01-01

    To prospectively evaluate a dedicated extremity cone-beam CT (CBCT) scanner in cases with and without orthopedic hardware by (1) comparing its imaging duration and image quality to those of radiography and multidetector CT (MDCT) and (2) comparing its radiation dose to that of MDCT. Written informed consent was obtained for all subjects for this IRB-approved, HIPAA-compliant study. Fifty subjects with (1) fracture of small bones, (2) suspected intraarticular fracture, (3) fracture at the site of complex anatomy, or (4) a surgical site difficult to assess with radiography alone were recruited and scanned on an extremity CBCT scanner prior to FDA approval. Same-day radiographs were performed in all subjects. Some subjects also underwent MDCT within 1 month of CBCT. Imaging duration and image quality were compared between CBCT and radiographs. Imaging duration, effective radiation dose, and image quality were compared between CBCT and MDCT. Fifty-one CBCT scans were performed in 50 subjects. Average imaging duration was shorter for CBCT than radiographs (4.5 min vs. 6.6 min, P = 0.001, n = 51) and MDCT (7.6 min vs. 10.9 min, P = 0.01, n = 7). Average estimated effective radiation dose was less for CBCT than MDCT (0.04 mSv vs. 0.13 mSv, P = 0.02, n = 7). CBCT images yielded more diagnostic information than radiographs in 23/51 cases and more diagnostic information than MDCT in 1/7 cases, although radiographs were superior for detecting hardware complications. CBCT performs high-resolution imaging of the extremities using less imaging time than radiographs and MDCT and lower radiation dose than MDCT. (orig.)

  15. Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Ambrose J.; Chang, Connie Y.; Palmer, William E. [Massachusetts General Hospital, Department of Radiology, Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States); Thomas, Bijoy J. [Universal College of Medical Sciences, Department of Radiology, Bhairahawa (Nepal); MacMahon, Peter J. [Mater Misericordiae University Hospital, Department of Radiology, Dublin 7 (Ireland)

    2015-06-01

    To prospectively evaluate a dedicated extremity cone-beam CT (CBCT) scanner in cases with and without orthopedic hardware by (1) comparing its imaging duration and image quality to those of radiography and multidetector CT (MDCT) and (2) comparing its radiation dose to that of MDCT. Written informed consent was obtained for all subjects for this IRB-approved, HIPAA-compliant study. Fifty subjects with (1) fracture of small bones, (2) suspected intraarticular fracture, (3) fracture at the site of complex anatomy, or (4) a surgical site difficult to assess with radiography alone were recruited and scanned on an extremity CBCT scanner prior to FDA approval. Same-day radiographs were performed in all subjects. Some subjects also underwent MDCT within 1 month of CBCT. Imaging duration and image quality were compared between CBCT and radiographs. Imaging duration, effective radiation dose, and image quality were compared between CBCT and MDCT. Fifty-one CBCT scans were performed in 50 subjects. Average imaging duration was shorter for CBCT than radiographs (4.5 min vs. 6.6 min, P = 0.001, n = 51) and MDCT (7.6 min vs. 10.9 min, P = 0.01, n = 7). Average estimated effective radiation dose was less for CBCT than MDCT (0.04 mSv vs. 0.13 mSv, P = 0.02, n = 7). CBCT images yielded more diagnostic information than radiographs in 23/51 cases and more diagnostic information than MDCT in 1/7 cases, although radiographs were superior for detecting hardware complications. CBCT performs high-resolution imaging of the extremities using less imaging time than radiographs and MDCT and lower radiation dose than MDCT. (orig.)

  16. The value of MDCT in diagnosis of hyaline-vascular Castleman's disease

    International Nuclear Information System (INIS)

    Sun, Xiaoli; Liu, Cheng; Wang, Rengui; Zhu, Xuejun; Gao, Li; Chen, Jiuhong

    2012-01-01

    Purpose: Castleman's disease (CD) is an uncommon entity characterized by a massive growth of lymphoid tissue. There are two types: the hyaline-vascular (HV) type and the plasma cell (PC) type. The purpose of this study was to evaluate the clinical value of multiple detector computed tomography (MDCT) in the diagnosis and planning of treatment for hyaline-vascular CD. Materials and methods: Fifty-two cases of confirmed hyaline-vascular CD were retrospectively reviewed. Unenhanced and contrast-enhanced MDCT scans had been performed in all patients, followed by surgery and pathological analysis of the lesion. Original MDCT transverse and reconstructed images were used for image interpretation. Features of the lesion and its adjacent structures were identified. Results: The lesion was present in the thorax of 24 patients and the abdomen in 28. Obvious features of hyaline-vascular CD (especially feeding vessels and draining veins) and its adjacent structures were demonstrated on 52 patients. Conclusion: On MDCT imaging, original MDCT transverse and reconstructed images provide an excellent tool for diagnosis of hyaline-vascular CD and have high value in the determination of a treatment plan

  17. Minimizing Contrast Medium Doses to Diagnose Pulmonary Embolism with 80-kVp Multidetector Computed Tomography in Azotemic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Holmquist, F. (Dept. of Diagnostic Radiology, Malmoe Univ. Hospital, Univ. of Lund, Malmoe (Sweden)); Hansson, K.; Pasquariello, F. (Dept. of Internal Medicine, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden)); Bjoerk, J. (Competence Center for Clinical Research, Univ. Hospital, Univ. of Lund, Lund (Sweden)); Nyman, U. (Dept. of Radiology, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden))

    2009-02-15

    Background: In diagnosing acute pulmonary embolism (PE) in azotemic patients, scintigraphy and magnetic resonance imaging are frequently inconclusive or not available in many hospitals. Computed tomography is readily available, but relatively high doses (30-50 g I) of potentially nephrotoxic iodine contrast media (CM) are used. Purpose: To report on the diagnostic quality and possible contrast-induced nephropathy (CIN) after substantially reduced CM doses to diagnose PE in azotemic patients using 80-peak kilovoltage (kVp) 16-row multidetector computed tomography (MDCT) combined with CM doses tailored to body weight, fixed injection duration adapted to scan time, automatic bolus tracking, and saline chaser. Material and Methods: Patients with estimated glomerular filtration rate (eGFR) <50 ml/min were scheduled to undergo 80-kVp MDCT using 200 mg I/kg, and those with eGFR =50 ml/min, 120-kVp MDCT with 320 mg I/kg. Both protocols used an 80-kg maximum dose weight and a fixed 15-s injection time. Pulmonary artery density and contrast-to-noise ratio were measured assuming 70 Hounsfield units (HU) for a fresh clot. CIN was defined as a plasma creatinine rise >44.2 mumol/l from baseline. Results: 89/148 patients (63/68 females) underwent 80-/120-kVp protocols, respectively, with 95% of the examinations being subjectively excellent or adequate. Mean values in the 80-/120-kVp cohorts regarding age were 82/65 years, body weight 66/78 kg, effective mAs 277/117, CM dose 13/23 g I, pulmonary artery density 359/345 HU, image noise (1 standard deviation) 24/21 HU, contrast-to-noise ratio 13/13, and dose-length product 173/258 mGycm. Only 1/65 and 2/119 patients in the 80- and 120-kVp cohorts, respectively, with negative CT and no anticoagulation suffered non-fatal thromboembolism during 3-month follow-up. No patient developed CIN. Conclusion: 80-kVp 16-row MDCT with optimization of injection parameters may be performed with preserved diagnostic quality, using markedly reduced CM

  18. Preoperative detection of colorectal liver metastases in fatty liver: MDCT or MRI?

    International Nuclear Information System (INIS)

    Kulemann, Vanessa; Schima, Wolfgang; Tamandl, Dietmar; Kaczirek, Klaus; Gruenberger, Thomas; Wrba, Friedrich; Weber, Michael; Ba-Ssalamah, Ahmed

    2011-01-01

    Objective: To compare the diagnostic value of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) in the preoperative detection of colorectal liver metastases in diffuse fatty infiltration of the liver, associated with neoadjuvant chemotherapy. Materials and methods: Twenty preoperative tri-phasic MDCT (4-64-row, Siemens) and dynamic contrast-enhanced MRI (1.5 T or 3.0 T, Siemens) examinations of patients with colorectal cancer and liver metastases in diffuse steatosis were retrospectively evaluated. All patients underwent surgical resection for liver metastases (time interval 1-60 days). The amount of fatty infiltration of the liver was determined histopathologically by semi-quantitative percent-wise estimation and ranged from 25 to 75%. Results: Overall, 51 metastases were found by histopathology of the resected liver segments/lobes. The size of the metastases ranged from 0.4 to 13 cm, with 18 (35%) being up to 1 cm in diameter. In the overall rating, MDCT detected 33/51 lesions (65%), and MRI 45/51 (88%). For lesions up to 1 cm, MDCT detected only 2/18 (11%) and MRI 12/18 (66%). One false positive lesion was detected by MDCT. Statistical analysis showed that MRI is markedly superior to MDCT, with a statistically significant difference (p 1 cm. Conclusion: For the detection of colorectal liver metastases after neoadjuvant chemotherapy and consecutive diffuse fatty infiltration of the liver, MRI is superior to MDCT, especially for the detection of small lesions.

  19. Comparison of the radiation dose from cone beam computed tomography and multidetector computed tomography in examinations of the hand; Vergleich der Strahlendosis von Cone-Beam Computertomografie und Multidetektor Computertomografie in Untersuchungen der Hand

    Energy Technology Data Exchange (ETDEWEB)

    Neubauer, J.; Neubauer, C.; Gerstmair, A.; Krauss, T.; Kotter, E.; Langer, M. [University Medical Center Freiburg (Germany). Dept. of Radiology; Reising, K. [University Medical Center Freiburg (Germany). Dept. of Orthopedics and Trauma Surgery; Zajonc, H. [University Medical Center Freiburg (Germany). Dept. of Plastic and Hand Surgery; Fiebich, M.; Voigt, J. [University of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection

    2016-05-15

    Comparison of radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in examinations of the hand. Dose calculations were carried out by means of Monte Carlo simulations in MDCT and CBCT. A corpse hand was examined in a 320-row MDCT scanner and a dedicated extremities CBCT scanner with standard protocols and multiple low-dose protocols. The image quality of the examinations was evaluated by 5 investigators using a Likert scale from 1 (very good) to 5 (very poor) regarding depiction of cortical bone, cancellous bone, joint surfaces, soft tissues and artifacts. For a sum of ratings of all structures < 50 a good overall image quality was expected. The studies with at least good overall image quality were compared with respect to the dose. The dose of the standard examination was 13.21 (12.96 to 13.46 CI) mGy in MDCT and 7.15 (6.99 to 7.30 CI) mGy in CBCT. The lowest dose in a study with good overall image quality was 4.54 (4.43 to 4.64 CI) mGy in MDCT and 5.72 (5.59 to 5.85 CI) mGy in CBCT. Although the dose of the standard protocols in the CBCT is lower than in the MDCT, the MDCT can realize a good overall image quality at a lower dose than the CBCT. Dose optimization of CT examination protocols for the hand is useful in both modalities, the MDCT has an even greater potential for optimization.

  20. MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach

    International Nuclear Information System (INIS)

    Rossi, Umberto G.; Seitun, Sara; Ferro, Carlo

    2011-01-01

    The purpose of this study is to report our preliminary experience using MDCT-guided percutaneous transthoracic needle aspiration biopsy using the transscapular approach in the upper posterolateral lung nodules, an area that it is difficult or hazardous to reach with the conventional approach. Five patients underwent CT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach. A coaxial needle technique was used in all patients. Biopsy was successful in all patients. No major complications were encountered. One patient developed a minimal pneumothorax next to the lesion immediately after biopsy, which resolved spontaneously. MDCT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach is an effective and safe procedure that reduces the risk of pneumothorax in selected patients.

  1. How accurate is unenhanced multidetector-row CT (MDCT) for localization of renal calculi?

    International Nuclear Information System (INIS)

    Goetschi, Stefan; Umbehr, Martin; Ullrich, Stephan; Glenck, Michael; Suter, Stefan; Weishaupt, Dominik

    2012-01-01

    Purpose: To investigate the correlation between unenhanced MDCT and intraoperative findings with regard to the exact anatomical location of renal calculi. Design, setting, and participants: Fifty-nine patients who underwent unenhanced MDCT for suspected urinary stone disease, and who underwent subsequent flexible ureterorenoscopy (URS) as treatment of nephrolithiasis were included in this retrospective study. All MDCT data sets were independently reviewed by three observers with different degrees of experience in reading CT. Each observer was asked to indicate presence and exact anatomical location of any calcification within pyelocaliceal system, renal papilla or renal cortex. Results were compared to intraoperative findings which have been defined as standard of reference. Calculi not described at surgery, but present on MDCT data were counted as renal cortex calcifications. Results: Overall 166 calculi in 59 kidneys have been detected on MDCT, 100 (60.2%) were located in the pyelocaliceal system and 66 (39.8%) in the renal parenchyma. Of the 100 pyelocaliceal calculi, 84 (84%) were correctly located on CT data sets by observer 1, 62 (62%) by observer 2, and 71 (71%) by observer 3. Sensitivity/specificity was 90–94% and 50–100% if only pyelocaliceal calculi measuring >4 mm in size were considered. For pyelocaliceal calculi ≤4 mm in size diagnostic performance of MDCT was inferior. Conclusion: Compared to flexible URS, unenhanced MDCT is accurate for distinction between pyelocaliceal calculi and renal parenchyma calcifications if renal calculi are >4 mm in size. For smaller renal calculi, unenhanced MDCT is less accurate and distinction between a pyelocaliceal calculus and renal parenchyma calcification is difficult.

  2. MDCT classification of osseous ankle and foot injuries; MDCT-Klassifikation knoecherner Verletzungen des oberen Sprunggelenks und des Fusses

    Energy Technology Data Exchange (ETDEWEB)

    Opherk, J.P.; Rosenthal, H.; Galanski, M. [Medizinische Hochschule, Abteilung Diagnostische Radiologie, Hannover (Germany)

    2007-03-15

    Conventional radiography plays an essential role in the primary evaluation of acute ankle and foot trauma. In the case of complex injuries, however, subsequent computed tomography (CT) is nowadays recommended. In this connection, multidetector computed tomography (MDCT) allows better temporal, spatial, and contrast resolution compared with the conventional single-slice spiral CT. Multiplanar reformation and three-dimensional reconstruction of the acquired data sets are also helpful tools for critical assessment of therapeutic intervention. This report reviews the potential of the MDCT technique for accurate fracture classification, precise illustration of displaced components, and postoperative control of arrangement of typical lesions. (orig.) [German] Die konventionelle Radiographie spielt bei der initialen Diagnostik akuter Verletzungen des oberen Sprunggelenks und des Fusses eine essenzielle Rolle. Im Falle komplexer Frakturen ist jedoch eine weiterfuehrende computertomographische Diagnostik empfehlenswert. Dabei ist die Multidetektorcomputertomographie (MDCT) der konventionellen Einzeilencomputertomographie hinsichtlich Zeit-, Orts- und Kontrastaufloesung deutlich ueberlegen. Die multiplanare Reformation und dreidimensionale Rekonstruktion des akquirierten Datensatzes sind zudem bei der Beurteilung therapeutischer Interventionen aussagekraeftige Werkzeuge. Der vorliegende Beitrag gibt einen Ueberblick ueber die exakte Frakturklassifikation, die praezise Abbildung dislozierter Komponenten und die postoperative Stellungskontrolle typischer Verletzungen mit dieser Technik. (orig.)

  3. Can independent coronal multiplanar reformatted images obtained using state-of-the-art MDCT scanners be used for primary interpretation of MDCT of the abdomen and pelvis? A feasibility study

    International Nuclear Information System (INIS)

    Sebastian, Sunit; Kalra, Mannudeep K.; Mittal, Pardeep; Saini, Sanjay; Small, William C.

    2007-01-01

    Purpose: To evaluate if coronal reformatted images can be used for primary interpretation of MDCT of the abdomen and pelvis using 64-slice MDCT. Materials and methods: IRB approval was obtained. We reviewed MDCT studies of the abdomen and pelvis of 220 consecutive patients performed with 64 row MDCT with constant scanning parameters. Based on a 0.625 mm raw data set, transverse images were reconstructed at 5 mm and coronal images at 3 mm using standard reconstruction algorithms. Reader familiarity was achieved by simultaneous evaluation of transverse and coronal reformats in an initial group of 20 separate cases for findings in consensus. Two subsequent phases of image analysis were then performed in two groups of 100 patients each. In the first phase two radiologists evaluated the added utility of simultaneous review of MDCT of transverse and coronal reformatted images over transverse images alone in 100 consecutive patients referred for MDCT of the abdomen and pelvis. In the second phase, the same radiologists evaluated whether coronal multiplanar reformats could be used for primary interpretation of MDCT of the abdomen and pelvis in a separate but similar cohort of 100 consecutive abdominopelvic MDCT studies. The number of lesion(s), their location, size of smallest lesion, presence of artifacts and likely diagnosis were noted at each image interpretation. Image quality and confidence for interpretation was evaluated using five-point and three-point scale, respectively. The time required for primary interpretation of coronal reformats and transverse images were recorded. Statistical analysis was performed using Wilcoxon signed rank test. Results: Both readers detected additional findings (n = 37, 35), respectively, on simultaneous review of transverse and coronal reformats as compared with transverse images alone (p < 0.001). Excellent interobserver agreement was noted (r = 0.94-0.96). Both readers detected additional findings (n = 62, 53), respectively, on

  4. Comparison of changes in tidal volume associated with expiratory rib cage compression and expiratory abdominal compression in patients on prolonged mechanical ventilation

    OpenAIRE

    Morino, Akira; Shida, Masahiro; Tanaka, Masashi; Sato, Kimihiro; Seko, Toshiaki; Ito, Shunsuke; Ogawa, Shunichi; Takahashi, Naoaki

    2015-01-01

    [Purpose] This study was designed to compare and clarify the relationship between expiratory rib cage compression and expiratory abdominal compression in patients on prolonged mechanical ventilation, with a focus on tidal volume. [Subjects and Methods] The subjects were 18 patients on prolonged mechanical ventilation, who had undergone tracheostomy. Each patient received expiratory rib cage compression and expiratory abdominal compression; the order of implementation was randomized. Subjects ...

  5. Evaluation of aortogenic embolic stroke using multi-detector row CT (MDCT)

    International Nuclear Information System (INIS)

    Mizuno, Masanori; Ooura, Kazumasa; Yamaguchi, Mao; Katsura, Noriyuki; Terayama, Yasuo

    2010-01-01

    Transesophageal cardioechography is one of the useful tools for detecting aortic arteriosclerosis causing aortogenic cerebral embolism. However, it is difficult to perform this method to all of the patients because of the technical difficulties due to patient's condition, especially the severity of atherosclerosis. To avoid the unexpected and adverse events, we are routinely applying multi-detector row CT (MDCT) to those patients. Among 10 cerebral embolic patients with unidentified embolic origin, MDCT revealed arteriosclerotic changes in aorta inducing mobile thrombus in 3 cases. The above data indicates that MDCT is safe and useful tool for diagnosis of aortogenic embolic stroke. (author)

  6. Expiratory muscle control during vomiting - Role of brain stem expiratory neurons

    Science.gov (United States)

    Miller, A. D.; Tan, L. K.

    1987-01-01

    The neural mechanisms controlling the muscles involved during vomiting were examined using decerebrated cats. In one experiment, the activity of the ventral respiratory group (VRG) expiratory (E) neurons was recorded during induced 'fictive vomiting' (i.e., a series of bursts of coactivation of abdominal and phrenic nerves that would be expected to produce expulsion in unparalyzed animals) and vomiting. In a second, abdominal muscle electromyographic and nerve activity were compared before and after sectioning the axons of descending VRG E neurons as they cross the midline between C1 and the obex (the procedure that is known to abolish expiratory modulation of internal intercostal muscle activity). The results of the study indicate that the abdominal muscles are controlled differently during respiration and vomiting.

  7. Utilization of low-dose multidetector CT and virtual bronchoscopy in children with suspected foreign body aspiration

    International Nuclear Information System (INIS)

    Adaletli, Ibrahim; Kurugoglu, Sebuh; Ulus, Sila; Ozer, Harun; Kantarci, Fatih; Mihmanli, Ismail; Akman, Canan; Elicevik, Mehmet

    2007-01-01

    Foreign body aspiration is common in children, especially those under 3 years of age. Chest radiography and CT are the main imaging modalities for the evaluation of these children. Management of children with suspected foreign body aspiration (SFBA) mainly depends on radiological findings. To investigate the potential use of low-dose multidetector CT (MDCT) and virtual bronchoscopy (VB) in the evaluation and management of SFBA in children. Included in the study were 37 children (17 girls, 20 boys; age 4 months to 10 years, mean 32 months) with SFBA. Chest radiographs were obtained prior to MDCT in all patients. MDCT was performed using a low-dose technique. VB images were obtained in the same session. Conventional bronchoscopy (CB) was performed within 24 h on patients in whom an obstructive abnormality had been found by MDCT and VB. Obstructive pathology was found in 16 (43.25%) of the 37 patients using MDCT and VB. In 13 of these patients, foreign bodies were detected and removed via CB. The foreign bodies were located in the right main bronchus (n = 5), in the bronchus intermedius (n = 6), in the medial segment of the middle lobe bronchus (n = 1), and in the left main bronchus (n = 1). In the remaining three patients, the diagnosis was false-positive for an obstructive pathology by MDCT and VB; the final diagnoses were secretions (n = 2) and schwannoma (n = 1), as demonstrated by CB. In 21 patients in whom no obstructive pathology was detected by MDCT and VB, CB was not performed. These patients were followed for 5-20 months without any recurrent obstructive symptomatology. Low-dose MDCT and VB are non-invasive radiological modalities that can be used easily in the investigation of SFBA in children. MDCT and VB provide the exact location of the obstructive pathology prior to CB. If obstructive pathology is depicted with MDCT and VB, CB should be performed either for confirmation of the diagnosis or for the diagnosis of an alternative cause for the obstruction

  8. Radiation dose from multidetector CT studies in children: results from the first Italian nationwide survey

    Energy Technology Data Exchange (ETDEWEB)

    Granata, Claudio [IRCCS Istituto Giannina Gaslini, Department of Radiology, Genoa (Italy); Origgi, Daniela; Palorini, Federica [Istituto Europeo di Oncologia, Department of Medical Physics, Milan (Italy); Matranga, Domenica [University of Palermo, Department of Sciences for Health Promotion and Mother and Child Care ' ' G. D' Alessandro' ' , Palermo (Italy); Salerno, Sergio [University of Palermo, Department of Medical and Forensic Biopathology and Biotechnologies, Section of Radiology, Palermo (Italy)

    2015-05-01

    Multidetector CT (MDCT) scanners have contributed to the widespread use of CT in paediatric imaging. However, concerns are raised for the associated radiation exposure. Very few surveys on radiation exposure from MDCT studies in children are available. The aim of this study was to outline the status of radiation exposure in children from MDCT practice in Italy. In this retrospective multicentre study we asked Italian radiology units with an MDCT scanner with at least 16 slices to provide dosimetric and acquisition parameters of CT examinations in three age groups (1-5, 6-10, 11-15 years) for studies of head, chest and abdomen. The dosimetric results were reported in terms of third-quartile volumetric CT dose index (CTDI{sub vol}) (mGy), size-specific dose estimate (SSDE) (mGy), dose length product (DLP) (mGy cm), and total DLP for multiphase studies. These results were compared with paediatric European and adult Italian published data. A multivariate analysis assessed the association of CTDI{sub vol} with patient characteristics and scanning modalities. We collected data from 993 MDCT examinations performed at 25 centres. For age groups 1-5 years, 6-10 years and 11-15 years, the CTDI{sub vol}, DLP and total DLP values were statistically significantly below the values observed in our analogous national survey in adults, although the difference decreased with increasing age. CTDI{sub vol} variability among centres was statistically significant (variance = 0.07; 95% confidence interval = 0.03-0.16; P < 0.001). This study reviewed practice in Italian centres performing paediatric imaging with MDCT scanners. The variability of doses among centres suggests that the use of standardised CT protocols should be encouraged. (orig.)

  9. Cumulative doses analysis in young trauma patients: a single-centre experience.

    Science.gov (United States)

    Salerno, Sergio; Marrale, Maurizio; Geraci, Claudia; Caruso, Giuseppe; Lo Re, Giuseppe; Lo Casto, Antonio; Midiri, Massimo

    2016-02-01

    Multidetector computed tomography (MDCT) represents the main source of radiation exposure in trauma patients. The radiation exposure of young patients is a matter of considerable medical concern due to possible long-term effects. Multiple MDCT studies have been observed in the young trauma population with an increase in radiation exposure. We have identified 249 young adult patients (178 men and 71 women; age range 14-40 years) who had received more than one MDCT study between June 2010 and June 2014. According to the International Commission on Radiological Protection publication, we have calculated the cumulative organ dose tissue-weighting factors by using CT-EXPO software(®). We have observed a mean cumulative dose of about 27 mSv (range from 3 to 297 mSv). The distribution analysis is characterised by low effective dose, below 20 mSv, in the majority of the patients. However, in 29 patients, the effective dose was found to be higher than 20 mSv. Dose distribution for the various organs analysed (breasts, ovaries, testicles, heart and eye lenses) shows an intense peak for lower doses, but in some cases high doses were recorded. Even though cumulative doses may have long-term effects, which are still under debate, high doses are observed in this specific group of young patients.

  10. Comparison of a dental cone beam CT with a multi-detector row CT on effective doses and physical image quality

    International Nuclear Information System (INIS)

    Yoshida, Yutaka; Tokumori, Kenji; Okamura, Kazutoshi; Yoshiura, Kazunori

    2011-01-01

    The purpose of this study was to compare a dental cone beam computed tomography (dental CBCT) and a multi-detector row CT (MDCT) using effective doses and physical image quality. A dental mode (D-mode) and an implant mode (I-mode) were employed for calculating effective doses. Field of view (FOV) size of the MDCT was 150 mm. Three types of images were obtained using 3 different reconstruction functions: FC1 (for abdomen images), FC30 (for internal ear and bone images) and FC81 (for high resolution images). Effective doses obtained with the D-mode and with the I-mode were about 20% and 50% of those obtained with the MDCT, respectively. Resolution properties obtained with the D-mode and I-mode were superior to that of the MDCT in a high frequency range. Noise properties of the D-mode and the I-mode were better than those with FC81. It was found that the dental CBCT has better potential as compared with MDCT in both dental and implant modes. (author)

  11. C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance

    International Nuclear Information System (INIS)

    Guggenberger, Roman; Ulbrich, Erika J.; Kaelin, Pascal; Pfammatter, Thomas; Alkadhi, Hatem; Andreisek, Gustav; Dietrich, Tobias J.; Scholz, Rosemarie; Koehler, Christoph; Elsaesser, Thilo; Le Corroller, Thomas

    2017-01-01

    To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between κ = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. (orig.)

  12. C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance

    Energy Technology Data Exchange (ETDEWEB)

    Guggenberger, Roman; Ulbrich, Erika J.; Kaelin, Pascal; Pfammatter, Thomas; Alkadhi, Hatem; Andreisek, Gustav [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zuerich (Switzerland); Dietrich, Tobias J. [Balgrist University Hospital, Department of Radiology, Zurich (Switzerland); Scholz, Rosemarie; Koehler, Christoph; Elsaesser, Thilo [Siemens Healthcare GmbH, Business Area Advanced Therapies, Forchheim (Germany); Le Corroller, Thomas [Aix-Marseille Universite, CNRS, ISM UMR 7287, Marseille (France); Radiology Department, APHM, Marseille (France)

    2017-02-15

    To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between κ = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. (orig.)

  13. MDCT classification of osseous ankle and foot injuries

    International Nuclear Information System (INIS)

    Opherk, J.P.; Rosenthal, H.; Galanski, M.

    2007-01-01

    Conventional radiography plays an essential role in the primary evaluation of acute ankle and foot trauma. In the case of complex injuries, however, subsequent computed tomography (CT) is nowadays recommended. In this connection, multidetector computed tomography (MDCT) allows better temporal, spatial, and contrast resolution compared with the conventional single-slice spiral CT. Multiplanar reformation and three-dimensional reconstruction of the acquired data sets are also helpful tools for critical assessment of therapeutic intervention. This report reviews the potential of the MDCT technique for accurate fracture classification, precise illustration of displaced components, and postoperative control of arrangement of typical lesions. (orig.) [de

  14. Positive expiratory pressure - Common clinical applications and physiological effects.

    Science.gov (United States)

    Fagevik Olsén, Monika; Lannefors, Louise; Westerdahl, Elisabeth

    2015-03-01

    Breathing out against resistance, in order to achieve positive expiratory pressure (PEP), is applied by many patient groups. Pursed lips breathing and a variety of devices can be used to create the resistance giving the increased expiratory pressure. Effects on pulmonary outcomes have been discussed in several publications, but the expected underlying physiology of the effect is seldom discussed. The aim of this article is to describe the purpose, performance, clinical application and underlying physiology of PEP when it is used to increase lung volumes, decrease hyperinflation or improve airway clearance. In clinical practice, the instruction how to use an expiratory resistance is of major importance since it varies. Different breathing patterns during PEP increase or reduce expiratory flow, result in movement of EPP centrally or peripherally and can increase or decrease lung volume. It is therefore necessary to give the right instructions to obtain the desired effects. As the different PEP techniques are being used by diverse patient groups it is not possible to give standard instructions. Based on the information given in this article the instructions have to be adjusted to give the optimal effect. There is no consensus regarding optimal treatment frequency and number of cycles included in each treatment session and must also be individualized. In future research, more precise descriptions are needed about physiological aims and specific instructions of how the treatments have been performed to assure as good treatment quality as possible and to be able to evaluate and compare treatment effects. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Lung function in North American Indian children: reference standards for spirometry, maximal expiratory flow volume curves, and peak expiratory flow.

    Science.gov (United States)

    Wall, M A; Olson, D; Bonn, B A; Creelman, T; Buist, A S

    1982-02-01

    Reference standards of lung function was determined in 176 healthy North American Indian children (94 girls, 82 boys) 7 to 18 yr of age. Spirometry, maximal expiratory flow volume curves, and peak expiratory flow rate were measured using techniques and equipment recommended by the American Thoracic Society. Standing height was found to be an accurate predictor of lung function, and prediction equations for each lung function variable are presented using standing height as the independent variable. Lung volumes and expiratory flow rates in North American Indian children were similar to those previously reported for white and Mexican-American children but were greater than those in black children. In both boys and girls, lung function increased in a curvilinear fashion. Volume-adjusted maximal expiratory flow rates after expiring 50 or 75% of FVC tended to decrease in both sexes as age and height increased. Our maximal expiratory flow volume curve data suggest that as North American Indian children grow, lung volume increases at a slightly faster rate than airway size does.

  16. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19,2016 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  17. Monte Carlo simulations in multi-detector CT (MDCT) for two PET/CT scanner models using MASH and FASH adult phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Belinato, W., E-mail: wbfisica@gmail.com [Bahia Federal Institute of Education, Science and Technology – IFBA, Vitória da Conquista, 45.100-000 (Brazil); Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil); Santos, W.S. [Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil); Paschoal, C.M.M., E-mail: cinthiam.paschoal@gmail.com [Department of Civil Engineering, Vale do Acarau State University – UVA, Sobral 62.040-730 (Brazil); Souza, D.N. [Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil)

    2015-06-01

    The combination of positron emission tomography (PET) and computed tomography (CT) has been extensively used in oncology for diagnosis and staging of tumors, radiotherapy planning and follow-up of patients with cancer, as well as in cardiology and neurology. This study determines by the Monte Carlo method the internal organ dose deposition for computational phantoms created by multidetector CT (MDCT) beams of two PET/CT devices operating with different parameters. The different MDCT beam parameters were largely related to the total filtration that provides a beam energetic change inside the gantry. This parameter was determined experimentally with the Accu-Gold Radcal measurement system. The experimental values of the total filtration were included in the simulations of two MCNPX code scenarios. The absorbed organ doses obtained in MASH and FASH phantoms indicate that bowtie filter geometry and the energy of the X-ray beam have significant influence on the results, although this influence can be compensated by adjusting other variables such as the tube current–time product (mAs) and pitch during PET/CT procedures.

  18. Volumetric expiratory high-resolution CT of the lung

    International Nuclear Information System (INIS)

    Nishino, Mizuki; Hatabu, Hiroto

    2004-01-01

    We developed a volumetric expiratory high-resolution CT (HRCT) protocol that provides combined inspiratory and expiratory volumetric imaging of the lung without increasing radiation exposure, and conducted a preliminary feasibility assessment of this protocol to evaluate diffuse lung disease with small airway abnormalities. The volumetric expiratory high-resolution CT increased the detectability of the conducting airway to the areas of air trapping (P<0.0001), and added significant information about extent and distribution of air trapping (P<0.0001)

  19. CT dose reduction using Automatic Exposure Control and iterative reconstruction: A chest paediatric phantoms study.

    Science.gov (United States)

    Greffier, Joël; Pereira, Fabricio; Macri, Francesco; Beregi, Jean-Paul; Larbi, Ahmed

    2016-04-01

    To evaluate the impact of Automatic Exposure Control (AEC) on radiation dose and image quality in paediatric chest scans (MDCT), with or without iterative reconstruction (IR). Three anthropomorphic phantoms representing children aged one, five and 10-year-old were explored using AEC system (CARE Dose 4D) with five modulation strength options. For each phantom, six acquisitions were carried out: one with fixed mAs (without AEC) and five each with different modulation strength. Raw data were reconstructed with Filtered Back Projection (FBP) and with two distinct levels of IR using soft and strong kernels. Dose reduction and image quality indices (Noise, SNR, CNR) were measured in lung and soft tissues. Noise Power Spectrum (NPS) was evaluated with a Catphan 600 phantom. The use of AEC produced a significant dose reduction (p<0.01) for all anthropomorphic sizes employed. According to the modulation strength applied, dose delivered was reduced from 43% to 91%. This pattern led to significantly increased noise (p<0.01) and reduced SNR and CNR (p<0.01). However, IR was able to improve these indices. The use of AEC/IR preserved image quality indices with a lower dose delivered. Doses were reduced from 39% to 58% for the one-year-old phantom, from 46% to 63% for the five-year-old phantom, and from 58% to 74% for the 10-year-old phantom. In addition, AEC/IR changed the patterns of NPS curves in amplitude and in spatial frequency. In chest paediatric MDCT, the use of AEC with IR allows one to obtain a significant dose reduction while maintaining constant image quality indices. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical audit

    International Nuclear Information System (INIS)

    Tack, Denis; Jahnen, Andreas; Kohler, Sarah; Harpes, Nico; Back, Carlo; Maertelaer, Viviane de; Gevenois, Pierre Alain

    2014-01-01

    To report short- and long-term effects of an audit process intended to optimise the radiation dose from multidetector row computed tomography (MDCT). A survey of radiation dose from all eight MDCT departments in the state of Luxembourg performed in 2007 served as baseline, and involved the most frequently imaged regions (head, sinus, cervical spine, thorax, abdomen, and lumbar spine). CT dose index volume (CTDIvol), dose-length product per acquisition (DLP/acq), and DLP per examination (DLP/exa) were recorded, and their mean, median, 25th and 75th percentiles compared. In 2008, an audit conducted in each department helped to optimise doses. In 2009 and 2010, two further surveys evaluated the audit's impact on the dose delivered. Between 2007 and 2009, DLP/exa significantly decreased by 32-69 % for all regions (P < 0.001) except the lumbar spine (5 %, P = 0.455). Between 2009 and 2010, DLP/exa significantly decreased by 13-18 % for sinus, cervical and lumbar spine (P ranging from 0.016 to less than 0.001). Between 2007 and 2010, DLP/exa significantly decreased for all regions (18-75 %, P < 0.001). Collective dose decreased by 30 % and the 75th percentile (diagnostic reference level, DRL) by 20-78 %. The audit process resulted in long-lasting dose reduction, with DRLs reduced by 20-78 %, mean DLP/examination by 18-75 %, and collective dose by 30 %. (orig.)

  1. Multidetector row computed tomography may accurately estimate plaque vulnerability. Does MDCT accurately estimate plaque vulnerability? (Pro)

    International Nuclear Information System (INIS)

    Komatsu, Sei; Imai, Atsuko; Kodama, Kazuhisa

    2011-01-01

    Over the past decade, multidetector row computed tomography (MDCT) has become the most reliable and established of the noninvasive examination techniques for detecting coronary heart disease. Now MDCT is chasing intravascular ultrasound (IVUS) in terms of spatial resolution. Among the components of vulnerable plaque, MDCT may detect lipid-rich plaque, the lipid pool, and calcified spots using computed tomography number. Plaque components are detected by MDCT with high accuracy compared with IVUS and angioscopy when assessing vulnerable plaque. The TWINS study and TOGETHAR trial demonstrated that angioscopic loss of yellow color occurred independently of volumetric plaque change by statin therapy. These 2 studies showed that plaque stabilization and regression reflect independent processes mediated by different mechanisms and time course. Noncalcified plaque and/or low-density plaque was found to be the strongest predictor of cardiac events, regardless of lesion severity, and act as a potential marker of plaque vulnerability. MDCT may be an effective tool for early triage of patients with chest pain who have a normal electrocardiogram (ECG) and cardiac enzymes in the emergency department. MDCT has the potential ability to analyze coronary plaque quantitatively and qualitatively if some problems are resolved. MDCT may become an essential tool for detecting and preventing coronary artery disease in the future. (author)

  2. Conventional and CT angiography in children: dosimetry and dose comparisons

    International Nuclear Information System (INIS)

    Frush, Donald P.; Yoshizumi, Terry

    2006-01-01

    Tremendous advances have been made in imaging in children with both congenital and acquired heart disease. These include technical advances in cardiac catheterization and conventional angiography, especially with advancements in interventional procedures, as well as noninvasive imaging with MR and CT angiography. With rapid advances in multidetector CT (MDCT) technology, most recently 64-detector array systems (64-slice MDCT), have come a number of advantages over MR. However, both conventional and CT angiography impart radiation dose to children. Although the presence of radiation exposure to children has long been recognized, it is apparent that our ability to assess this dose, particularly in light of the rapid advancements, has been limited. Traditional methods of dosimetry for both conventional and CT angiography are somewhat cumbersome or involve a potential for substantial uncertainty. Recent developments in dosimetry, including metal oxide semiconductor field effect transistors (MOSFET) and the availability of anthropomorphic, tissue-equivalent phantoms have provided new opportunities for dosimetric assessments. Recent work with this technology in state-of-the-art cardiac angiography suites as well as with MDCT have offered direct comparisons of doses in infants and children undergoing diagnostic cardiac evaluation. It is with these dose data that assessment of risks, and ultimately the assessment of risk-benefit, can be better achieved. (orig.)

  3. Usefulness of high helical pitch acquisition for reduction of patient radiation dose in cardiac multidetector computed tomography

    International Nuclear Information System (INIS)

    Sano, Tomonari; Matsutani, Hideyuki; Kondo, Takeshi; Sekine, Takako; Arai, Takehiro; Morita, Hitomi; Takase, Shinichi

    2009-01-01

    Helical pitch (HP) usually has been decided automatically by the software (Heart Navi) included in the MDCT machine (Aquilion 64) depending on gantry rotation speed (r) and heart rate (HR). To reduce radiation dose, 255 consecutive patients with low HR (≤60 bpm) and without arrhythmia underwent cardiac MDCT using high HP. We had already reported that the relationship among r, HP, and the maximum data acquisition time interval (Tmax) does not create the data deficit in arrhythmia. It was represented as Tmax=(69.88/HP-0.64) r; (equation 1). From equation 1, HP=69.88 r/(Tmax+0.64 r); (equation 2) was derived. We measured the maximum R-R interval (R-Rmax) on electrocardiogram (ECG) before multi detector row CT (MDCT) acquisition, and R-Rmax x 1.1 was calculated as Tmax in consideration of R-Rmax prolongation during MDCT acquisition. The HP of high HP acquisition was calculated from equation 2. In HR≤50 bpm, Heart Navi determined r: 0.35 sec/rot and HP: 9.8, and in 51 bpm≤HR≤66 bpm, r:0.35 sec/rot and HP: 11.2. HP of the high HP (16.4±1.2) was significantly (p<0.0001) higher than that of Heart Navi HP (10.9±0.6). The scanning time (6.5±0.6 sec) of high HP was significantly (p<0.0001) shorter than that of Heart Navi (9.0±0.8 sec), and the dose length product of high HP (675±185 mGy·cm) was significantly (p<0.0001) lower than that of Heart Navi (923±252 mGy·cm). The high HP could produce fine images in 251/255 patients. In conclusion, the high HP acquisition is useful for reduction of radiation dose and scanning time. (author)

  4. Diagnostic imaging strategy for MDCT- or MRI-detected breast lesions: use of targeted sonography

    International Nuclear Information System (INIS)

    Nakano, Satoko; Ohtsuka, Masahiko; Mibu, Akemi; Karikomi, Masato; Sakata, Hitomi; Yamamoto, Masahiro

    2012-01-01

    Leading-edge technology such as magnetic resonance imaging (MRI) or computed tomography (CT) often reveals mammographically and ultrasonographically occult lesions. MRI is a well-documented, effective tool to evaluate these lesions; however, the detection rate of targeted sonography varies for MRI detected lesions, and its significance is not well established in diagnostic strategy of MRI detected lesions. We assessed the utility of targeted sonography for multidetector-row CT (MDCT)- or MRI-detected lesions in practice. We retrospectively reviewed 695 patients with newly diagnosed breast cancer who were candidates for breast conserving surgery and underwent MDCT or MRI in our hospital between January 2004 and March 2011. Targeted sonography was performed in all MDCT- or MRI-detected lesions followed by imaging-guided biopsy. Patient background, histopathology features and the sizes of the lesions were compared among benign, malignant and follow-up groups. Of the 695 patients, 61 lesions in 56 patients were detected by MDCT or MRI. The MDCT- or MRI-detected lesions were identified by targeted sonography in 58 out of 61 lesions (95.1%). Patients with pathological diagnoses were significantly older and more likely to be postmenopausal than the follow-up patients. Pathological diagnosis proved to be benign in 20 cases and malignant in 25. The remaining 16 lesions have been followed up. Lesion size and shape were not significantly different among the benign, malignant and follow-up groups. Approximately 95% of MDCT- or MRI-detected lesions were identified by targeted sonography, and nearly half of these lesions were pathologically proven malignancies in this study. Targeted sonography is a useful modality for MDCT- or MRI-detected breast lesions

  5. Malignant renal cysts: Diagnostic performance and strong predictors at MDCT

    International Nuclear Information System (INIS)

    Kim, Dae Yoon; Kim, Jeong Kon; Cho, Kyoung-Sik; Min, Gyeong-Eun; Ahn, Han-Jong

    2010-01-01

    Background: Utilization of multidetector-row CT (MDCT) is anticipated to improve the diagnostic accuracy and reliability for determining malignant cysts. Purpose: To assess the diagnostic accuracy, interobserver agreement, benefit of consensus reading, and strong predictors of malignancy in determining malignant cystic renal masses at MDCT. Material and Methods: Two radiologists independently rated the probability of malignancy at MDCT in 72 benign and 53 malignant cysts. The accuracy and interobserver agreement for determining malignant cysts were evaluated. The strong predictors of malignancy were determined, and in patients with interobserver disagreement for determining malignant cysts, consensus readings were performed. Results: Az value of the two readers was 0.905-0.936 and the sensitivity and specificity were 85-89% and 83-93%, respectively. The overall interobserver agreement for determining the malignant cyst was good as the κ value was 0.696 (% agreement, 61% (76/125)). Thickened irregular wall, thickened irregular septa, and enhancing soft tissue component were strong predictors for malignancy with both readers. In the 17 patients with interobserver disagreement for determining malignant cysts, the sensitivity was improved from 38-63% to 89% by the consensus reading. Conclusion: At MDCT, some false negative decisions for determining malignant cysts can be corrected by consensus reading, and thickened irregular septa, thickened irregular wall, and enhancing soft tissue component are the strong predictors of malignant cysts

  6. Two examples of indication specific radiation dose calculations in dental CBCT and Multidetector CT scanners.

    Science.gov (United States)

    Stratis, Andreas; Zhang, Guozhi; Lopez-Rendon, Xochitl; Politis, Constantinus; Hermans, Robert; Jacobs, Reinhilde; Bogaerts, Ria; Shaheen, Eman; Bosmans, Hilde

    2017-09-01

    To calculate organ doses and estimate the effective dose for justification purposes in patients undergoing orthognathic treatment planning purposes and temporal bone imaging in dental cone beam CT (CBCT) and Multidetector CT (MDCT) scanners. The radiation dose to the ICRP reference male voxel phantom was calculated for dedicated orthognathic treatment planning acquisitions via Monte Carlo simulations in two dental CBCT scanners, Promax 3D Max (Planmeca, FI) and NewTom VGi evo (QR s.r.l, IT) and in Somatom Definition Flash (Siemens, DE) MDCT scanner. For temporal bone imaging, radiation doses were calculated via MC simulations for a CBCT protocol in NewTom 5G (QR s.r.l, IT) and with the use of a software tool (CT-expo) for Somatom Force (Siemens, DE). All procedures had been optimized at the acceptance tests of the devices. For orthognathic protocols, dental CBCT scanners deliver lower doses compared to MDCT scanners. The estimated effective dose (ED) was 0.32mSv for a normal resolution operation mode in Promax 3D Max, 0.27mSv in VGi-evo and 1.18mSv in the Somatom Definition Flash. For temporal bone protocols, the Somatom Force resulted in an estimated ED of 0.28mSv while for NewTom 5G the ED was 0.31 and 0.22mSv for monolateral and bilateral imaging respectively. Two clinical exams which are carried out with both a CBCT or a MDCT scanner were compared in terms of radiation dose. Dental CBCT scanners deliver lower doses for orthognathic patients whereas for temporal bone procedures the doses were similar. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Physiological and morphological determinants of maximal expiratory flow in chronic obstructive lung disease

    NARCIS (Netherlands)

    H.A.W.M. Tiddens (Harm); J.M. Bogaard (Jan); J.C. de Jongste (Johan); W.C.J. Hop (Wim); H.O. Coxson (Harvey); P.D. Pare

    1996-01-01

    textabstractMaximal expiratory flow in chronic obstructive pulmonary disease (COPD) could be reduced by three different mechanisms; loss of lung elastic recoil, decreased airway conductance upstream of flow-limiting segments; and increased collapsibility of airways.

  8. Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical audit

    Energy Technology Data Exchange (ETDEWEB)

    Tack, Denis [EpiCURA Hospital, Clinique Louis Caty, Department of Radiology, Baudour (Belgium); Jahnen, Andreas; Kohler, Sarah [CRP Henri Tudor, Luxembourg (Luxembourg); Harpes, Nico; Back, Carlo [Ministry of Health, Department of Radiation Protection, Luxembourg (Luxembourg); Maertelaer, Viviane de [Universite libre de Bruxelles, Institut de Recherche Interdisciplinaire en Biologie Humaine et Moleculaire and SBIM, Statistical Unit, Brussels (Belgium); Gevenois, Pierre Alain [Hopital Erasme, Department of Radiology, Brussels (Belgium)

    2014-01-15

    To report short- and long-term effects of an audit process intended to optimise the radiation dose from multidetector row computed tomography (MDCT). A survey of radiation dose from all eight MDCT departments in the state of Luxembourg performed in 2007 served as baseline, and involved the most frequently imaged regions (head, sinus, cervical spine, thorax, abdomen, and lumbar spine). CT dose index volume (CTDIvol), dose-length product per acquisition (DLP/acq), and DLP per examination (DLP/exa) were recorded, and their mean, median, 25th and 75th percentiles compared. In 2008, an audit conducted in each department helped to optimise doses. In 2009 and 2010, two further surveys evaluated the audit's impact on the dose delivered. Between 2007 and 2009, DLP/exa significantly decreased by 32-69 % for all regions (P < 0.001) except the lumbar spine (5 %, P = 0.455). Between 2009 and 2010, DLP/exa significantly decreased by 13-18 % for sinus, cervical and lumbar spine (P ranging from 0.016 to less than 0.001). Between 2007 and 2010, DLP/exa significantly decreased for all regions (18-75 %, P < 0.001). Collective dose decreased by 30 % and the 75th percentile (diagnostic reference level, DRL) by 20-78 %. The audit process resulted in long-lasting dose reduction, with DRLs reduced by 20-78 %, mean DLP/examination by 18-75 %, and collective dose by 30 %. (orig.)

  9. Automatic detection of osteoporotic vertebral fractures in routine thoracic and abdominal MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Baum, Thomas; Dobritz, Martin; Rummeny, Ernst J.; Noel, Peter B. [Technische Universitaet Muenchen, Institut fuer Radiologie, Klinikum rechts der Isar, Muenchen (Germany); Bauer, Jan S. [Technische Universitaet Muenchen, Abteilung fuer Neuroradiologie, Klinikum rechts der Isar, Muenchen (Germany); Klinder, Tobias; Lorenz, Cristian [Philips Research Laboratories, Hamburg (Germany)

    2014-04-15

    To develop a prototype algorithm for automatic spine segmentation in MDCT images and use it to automatically detect osteoporotic vertebral fractures. Cross-sectional routine thoracic and abdominal MDCT images of 71 patients including 8 males and 9 females with 25 osteoporotic vertebral fractures and longitudinal MDCT images of 9 patients with 18 incidental fractures in the follow-up MDCT were retrospectively selected. The spine segmentation algorithm localised and identified the vertebrae T5-L5. Each vertebra was automatically segmented by using corresponding vertebra surface shape models that were adapted to the original images. Anterior, middle, and posterior height of each vertebra was automatically determined; the anterior-posterior ratio (APR) and middle-posterior ratio (MPR) were computed. As the gold standard, radiologists graded vertebral fractures from T5 to L5 according to the Genant classification in consensus. Using ROC analysis to differentiate vertebrae without versus with prevalent fracture, AUC values of 0.84 and 0.83 were obtained for APR and MPR, respectively (p < 0.001). Longitudinal changes in APR and MPR were significantly different between vertebrae without versus with incidental fracture (ΔAPR: -8.5 % ± 8.6 % versus -1.6 % ± 4.2 %, p = 0.002; ΔMPR: -11.4 % ± 7.7 % versus -1.2 % ± 1.6 %, p < 0.001). This prototype algorithm may support radiologists in reporting currently underdiagnosed osteoporotic vertebral fractures so that appropriate therapy can be initiated. circle This spine segmentation algorithm automatically localised, identified, and segmented the vertebrae in MDCT images. (orig.)

  10. BMD measurements of the spine derived from sagittal reformations of contrast-enhanced MDCT without dedicated software

    Energy Technology Data Exchange (ETDEWEB)

    Baum, Thomas, E-mail: thbaum@gmx.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Mueller, Dirk, E-mail: dirk.mueller@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Dobritz, Martin, E-mail: dobritz@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Rummeny, Ernst J., E-mail: institut@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Link, Thomas M., E-mail: thomas.link@radiology.ucsf.edu [Musculoskeletal and Quantitative Imaging Research, Department of Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry Street, Suite 350, San Francisco, CA 94107 (United States); Bauer, Jan S., E-mail: jsb@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany)

    2011-11-15

    Purpose: To assess QCT equivalent BMD of the lumbar spine in sagittal reformations of routine abdominal contrast-enhanced MDCT with simple PACS measurement tools and to apply this method to MDCT datasets for differentiating patients with and without osteoporotic vertebral fractures. Materials and methods: Eight postmenopausal women (65 {+-} 5years) underwent standard QCT to assess BMD of L1-L3. Afterwards routine abdominal contrast-enhanced MDCT images of these women were obtained and apparent BMD of L1-L3 was measured using the sagittal reformations. The MDCT-to-QCT conversion equation for BMD was calculated with linear regression analysis. The conversion equation was applied to vertebral BMD datasets (L1-L3) of 75 postmenopausal women (66 {+-} 4years). Seventeen of the 75 patients had osteoporotic vertebral fractures. Results: BMD values of contrast-enhanced MDCT were on average 56 mg/ml higher than those of standard QCT. A correlation coefficient of r = 0.94 (p < 0.05) was calculated for the BMD values of MDCT and standard QCT with the conversion equation BMD{sub QCT} = 0.69 x BMD{sub MDCT} - 11 mg/ml. Accordingly converted BMD values of patients with vertebral fractures were significantly lower than those of patients without vertebral fractures (69 mg/ml vs. 85 mg/ml; p < 0.05). Using ROC analysis to differentiate patients with and without vertebral fractures, AUC = 0.72 was obtained for converted BMD values (p < 0.05). Short- and long-term reproducibility errors for BMD measurements in the sagittal reformations amounted 2.09% and 7.70%, respectively. Conclusion: BMD measurements of the spine could be computed in sagittal reformations of routine abdominal contrast-enhanced MDCT with minimal technical and time effort. Using the conversion equation, the acquired BMD data could differentiate patients with and without osteoporotic vertebral fractures.

  11. Multidetector computed tomography enteroclysis (MDCT-E) with neutral enteral and IV contrast enhancement in tumor detection

    Energy Technology Data Exchange (ETDEWEB)

    Romano, Stefania; Lutio, Elisabetta de; Romano, Luigia [Cardarelli Hospital, Department of Diagnostic Imaging, Naples (Italy); Rollandi, Gian Andrea [San Martino Hospital, 2. Service of Radiology, Genova (Italy); Grassi, Roberto [Second University of Naples, Institute of Radiology, Naples (Italy); Maglinte, Dean D.T. [Indiana University School of Medicine, Department of Radiology, Indianapolis, IN (United States)

    2005-06-01

    The aim of our study was to evaluate the reliability of MDCT-enteroclysis (MDCT-E), an emerging technique of small bowel examination that combines the advantages of MDCT examination of the abdomen and the enteral volume challenge of enteroclysis, in evaluation of small bowel neoplasms. In our institutions, MDCT-E was used to study 456 patients (age range 21-84 years, mean 53 years) admitted for suspicion of small bowel disease. All examinations were done on multichannel CT units, 129 on a 16-slice scanner and 327 on a four-slice scanner. Post-processing and multiplanar reformatting and interpretation were performed on dedicated workstations. After adequate gastrointestinal preparation and naso-enteric intubation, small bowel was distended by methylcellulose infused by a peristaltic pump. One volumetric MDCT acquisition was obtained after 120-130 ml of intravenous contrast medium. Multiplanar reformatting was based on the image reconstruction parameters from 3 to 4 mm. Forty-five small bowel neoplasms were found; in the remaining cases, 223 Crohn's diseases and 149 other abnormalities were detected. All findings were confirmed by surgery, endoscopy or clinical follow-up. In our experience, MDCT-E with neutral enteral and IV contrast seems to be a reliable method in the diagnosis of small bowel neoplasms. (orig.)

  12. A method of estimating conceptus doses resulting from multidetector CT examinations during all stages of gestation

    International Nuclear Information System (INIS)

    Damilakis, John; Tzedakis, Antonis; Perisinakis, Kostas; Papadakis, Antonios E.

    2010-01-01

    Purpose: Current methods for the estimation of conceptus dose from multidetector CT (MDCT) examinations performed on the mother provide dose data for typical protocols with a fixed scan length. However, modified low-dose imaging protocols are frequently used during pregnancy. The purpose of the current study was to develop a method for the estimation of conceptus dose from any MDCT examination of the trunk performed during all stages of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study to model the Siemens Sensation 16 and Sensation 64 MDCT scanners. Four mathematical phantoms were used, simulating women at 0, 3, 6, and 9 months of gestation. The contribution to the conceptus dose from single simulated scans was obtained at various positions across the phantoms. To investigate the effect of maternal body size and conceptus depth on conceptus dose, phantoms of different sizes were produced by adding layers of adipose tissue around the trunk of the mathematical phantoms. To verify MCNP results, conceptus dose measurements were carried out by means of three physical anthropomorphic phantoms, simulating pregnancy at 0, 3, and 6 months of gestation and thermoluminescence dosimetry (TLD) crystals. Results: The results consist of Monte Carlo-generated normalized conceptus dose coefficients for single scans across the four mathematical phantoms. These coefficients were defined as the conceptus dose contribution from a single scan divided by the CTDI free-in-air measured with identical scanning parameters. Data have been produced to take into account the effect of maternal body size and conceptus position variations on conceptus dose. Conceptus doses measured with TLD crystals showed a difference of up to 19% compared to those estimated by mathematical simulations. Conclusions: Estimation of conceptus doses from MDCT examinations of the trunk performed on pregnant patients during all stages of gestation can be made

  13. Fulminant hepatic failure in children: Etiology, histopathology and MDCT findings

    International Nuclear Information System (INIS)

    Cakir, Banu; Kirbas, Ismail; Demirhan, Beyhan; Tarhan, Nefise Cagla; Bozkurt, Alper; Ozcay, Figen; Coskun, Mehmet

    2009-01-01

    Introduction: The purpose of this study is to determine the etiologies, histopathology and MDCT findings of children with fulminant hepatic failure admitted to our institution. Materials and methods: Between June 2004 and November 2006, 15 children with fulminant hepatic failure who underwent MDCT were included retrospectively in this study. Twelve patients had liver biopsies. The patients were divided into three groups as hyperacute (Group I), acute (Group II) and subacute (Group III) depending on onset of hepatic encephalopathy. Results: Hepatitis A in 4 patients, non-A, non-E hepatitis in 4; mushroom poisoning in 3; fulminant Wilson's disease in 2; autoimmune hepatitis in 1; and both hepatitis B and toxic hepatitis (with leflunomide treatment) in 1 patient were detected. MDCT of all three groups revealed diffuse reduction in hepatic attenuation in 11 patients; ascites in 9; periportal edema in 6; edema of gallbladder wall in 6; splenomegaly in 6; heterogeneous hepatic parenchyma in 6; hepatomegaly in 3; irregular contours of liver in 2; multiple micronodules in 1 and necrotic areas and regeneration in liver parenchyma in 2 patients. Histopathologic evaluation of liver biopsies showed massive hepatic necrosis, inflammatory cell infiltration and ductular proliferation in 8 patients, periportal edema in 6, edema of gallbladder wall in 5, regenerating nodules and fibrous septa consistent with cirrhotic pattern in 2, and regenerating nodules and necrotic areas in 2 patients. Conclusion: The most common MDCT findings in fulminant hepatic failure were diffuse reduction in hepatic attenuation and ascites. Massive hepatic necrosis was the most common histopathologic finding.

  14. Fulminant hepatic failure in children: Etiology, histopathology and MDCT findings

    Energy Technology Data Exchange (ETDEWEB)

    Cakir, Banu [Baskent University Faculty of Medicine Department of Radiology, Fevzi Cakmak Cd. 10, Sok. No: 45, Bahcelievler, Ankara 06490 (Turkey)], E-mail: banutopcu@yahoo.com; Kirbas, Ismail [Baskent University Faculty of Medicine Department of Radiology, Fevzi Cakmak Cd. 10, Sok. No: 45, Bahcelievler, Ankara 06490 (Turkey)], E-mail: drismailk@yahoo.com; Demirhan, Beyhan [Baskent University Faculty of Medicine Department of Pathology, Fevzi Cakmak Cd. 10, Sok. No: 45, Bahcelievler, Ankara 06490 (Turkey)], E-mail: beyhand@baskent-ank.edu.tr; Tarhan, Nefise Cagla [Baskent University Faculty of Medicine Department of Radiology, Fevzi Cakmak Cd. 10, Sok. No: 45, Bahcelievler, Ankara 06490 (Turkey)], E-mail: caglat@gmail.com; Bozkurt, Alper [Baskent University Faculty of Medicine Department of Radiology, Fevzi Cakmak Cd. 10, Sok. No: 45, Bahcelievler, Ankara 06490 (Turkey)], E-mail: abozkurt78@hotmail.com; Ozcay, Figen [Baskent University Faculty of Medicine Department of Pediatric Gastroenterology, Fevzi Cakmak Cd. 10, Sok. No: 45, Bahcelievler, Ankara 06490 (Turkey)], E-mail: fozcay@baskent.edu.tr; Coskun, Mehmet [Baskent University Faculty of Medicine Department of Radiology, Fevzi Cakmak Cd. 10, Sok. No: 45, Bahcelievler, Ankara 06490 (Turkey)], E-mail: mcoskun@baskent-ank.edu.tr

    2009-11-15

    Introduction: The purpose of this study is to determine the etiologies, histopathology and MDCT findings of children with fulminant hepatic failure admitted to our institution. Materials and methods: Between June 2004 and November 2006, 15 children with fulminant hepatic failure who underwent MDCT were included retrospectively in this study. Twelve patients had liver biopsies. The patients were divided into three groups as hyperacute (Group I), acute (Group II) and subacute (Group III) depending on onset of hepatic encephalopathy. Results: Hepatitis A in 4 patients, non-A, non-E hepatitis in 4; mushroom poisoning in 3; fulminant Wilson's disease in 2; autoimmune hepatitis in 1; and both hepatitis B and toxic hepatitis (with leflunomide treatment) in 1 patient were detected. MDCT of all three groups revealed diffuse reduction in hepatic attenuation in 11 patients; ascites in 9; periportal edema in 6; edema of gallbladder wall in 6; splenomegaly in 6; heterogeneous hepatic parenchyma in 6; hepatomegaly in 3; irregular contours of liver in 2; multiple micronodules in 1 and necrotic areas and regeneration in liver parenchyma in 2 patients. Histopathologic evaluation of liver biopsies showed massive hepatic necrosis, inflammatory cell infiltration and ductular proliferation in 8 patients, periportal edema in 6, edema of gallbladder wall in 5, regenerating nodules and fibrous septa consistent with cirrhotic pattern in 2, and regenerating nodules and necrotic areas in 2 patients. Conclusion: The most common MDCT findings in fulminant hepatic failure were diffuse reduction in hepatic attenuation and ascites. Massive hepatic necrosis was the most common histopathologic finding.

  15. Ultra-high resolution C-Arm CT arthrography of the wrist: Radiation dose and image quality compared to conventional multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Werncke, Thomas, E-mail: Werncke.Thomas@mh-hannover.de [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Sonnow, Lena; Meyer, Bernhard C. [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Lüpke, Matthias [University of Veterinary Medicine Hannover, Institute for General Radiology and Medical Physics, Bischofsholer Damm 15, 30173 Hannover (Germany); Hinrichs, Jan; Wacker, Frank K.; Falck, Christian von [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany)

    2017-04-15

    Objective: Objective of this phantom and cadaveric study was to compare the effective radiation dose (ED) and image quality (IQ) between C-arm computed tomography (CACT) using an ultra-high resolution 1 × 1 binning with a standard 16-slice CT (MDCT) arthrography of the wrist. Methods: ED was determined with thermoluminescence dosimetry using an anthropomorphic phantom and different patient positions. Imaging was conducted in 10 human cadaveric wrists after tri-compartmental injection of diluted iodinated contrast material and a wire phantom. IQ of MDCT was compared with CACT reconstructed with a soft (CACT1) and sharp (CACT2) kernel. High and low contrast resolution was determined. Three radiologists assessed IQ of wrist structures and occurrence of image artifacts using a 5-point Likert scale. Results: ED of MDCT was comparable to standard CACT (4.3 μSv/3.7 μSv). High contrast resolution was best for CACT2, decreased to CACT1 and MDCT. Low contrast resolution increased between CACT2 and MDCT (P < 0.001). IQ was best for CACT2 (1.3 ± 0.5), decreased to CACT1 (1.9 ± 0.6) and MDCT (3.5 ± 0.6). Non-compromising artifacts were only reported for CACT. Conclusions: The results of this phantom and cadaveric study indicate that ultra-high resolution C-Arm CT arthrography of the wrist bears the potential to outperform MDCT arthrography in terms of image quality and workflow at the cost of mildly increasing image artifacts while radiation dose to the patient is comparably low for both, MDCT and C-Arm CT.

  16. Impact of Multidetector Computerized Tomography (MDCT) On The General Population

    Energy Technology Data Exchange (ETDEWEB)

    Leite, B.B.; Ribeiro, N.C. [Servico de Radiologia, Hospital de Curry Cabral, Rua da Beneficencia, 8, 1069-166 Lisboa (Portugal)

    2009-05-15

    Multidetector computerized tomography (MDCT) appeared in the early 1990s, as a technological evolution of computerized tomography. As one would expect, the evolution continues and, each year, more powerful equipments appear, with new medical applications. However, the general use of this technique has lead to the dramatic increase on the general population irradiation. Special concern is required regarding the most vulnerable groups, like the pediatric population, the pregnant and the young female. Due to a larger awareness of this irradiation risks, some initiatives have been developed, coming from different areas, aiming to maximize the benefit to risk ratio of MDCT. (author)

  17. Ectopic Varices in Colonic Stoma: MDCT Findings

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jae Woong; Lee, Chang Hee; Kim, Kyeong Ah; Park, Cheol Min; Kim, Jin Yong [Guro Hospital of Korea University, Seoul (Korea, Republic of)

    2006-12-15

    We describe the 2D reformatted and 3D volume rendered images by MDCT in a patient with an episode of acute bleeding from the colonic stoma. This case indicates that the 2D reformatted and 3D volume rendered images are useful to detect this rare complication of portal hypertension, and they help to tailor adequate treatment for the patients with bleeding from stomal varices. Ectopic varices are an uncommon cause of gastrointestinal hemorrhage, but they account for up to 5% of all variceal bleedings (1). Bleeding from stomal varices has been reported in up to 20% of the patients suffering with chronic liver failure with permanent stoma (2). However, the diagnosis of stomal varices is difficult because bleeding from stoma may also be associated with lower gastrointestinal bleeding. To the best of our knowledge, the 2D reformatted and 3D volume rendered images by MDCT for visualization of ectopic stomal varices have not been previously reported in the medical literature.

  18. Effect of Training Frequency on Maximum Expiratory Pressure

    Science.gov (United States)

    Anand, Supraja; El-Bashiti, Nour; Sapienza, Christine

    2012-01-01

    Purpose: To determine the effects of expiratory muscle strength training (EMST) frequency on maximum expiratory pressure (MEP). Method: We assigned 12 healthy participants to 2 groups of training frequency (3 days per week and 5 days per week). They completed a 4-week training program on an EMST trainer (Aspire Products, LLC). MEP was the primary…

  19. Evaluation of a dedicated MDCT protocol using iterative image reconstruction after cervical spine trauma.

    Science.gov (United States)

    Geyer, L L; Körner, M; Hempel, R; Deak, Z; Mueck, F G; Linsenmaier, U; Reiser, M F; Wirth, S

    2013-07-01

    To evaluate radiation exposure for 64-row computed tomography (CT) of the cervical spine comparing two optimized protocols using filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR), respectively. Sixty-seven studies using FBP (scanner 1) were retrospectively compared with 80 studies using ASIR (scanner 2). The key scanning parameters were identical (120 kV dose modulation, 64 × 0.625 mm collimation, pitch 0.531:1). In protocol 2, the noise index (NI) was increased from 5 to 25, and ASIR and the high-definition (HD) mode were used. The scan length, CT dose index (CTDI), and dose-length product (DLP) were recorded. The image quality was analysed subjectively by using a three-point scale (0; 1; 2), and objectively by using a region of interest (ROI) analysis. Mann-Whitney U and Wilcoxon's test were used. In the FBP group, the mean CTDI was 21.43 mGy, mean scan length 186.3 mm, and mean DLP 441.15 mGy cm. In the ASIR group, the mean CTDI was 9.57 mGy, mean scan length 195.21 mm, and mean DLP 204.23 mGy cm. The differences were significant for CTDI and DLP (p 0.05). The estimated mean effective dose decreased from 2.38 mSv (FBP) to 1.10 mSv (ASIR). The radiation dose of 64-row MDCT can be reduced to a level comparable to plain radiography without loss of subjective image quality by implementation of ASIR in a dedicated cervical spine trauma protocol. These results might contribute to an improved relative risk-to-benefit ratio and support the justification of CT as a first-line imaging tool to evaluate cervical spine trauma. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  20. MDCT findings in sports and recreational accidents.

    Science.gov (United States)

    Bensch, Frank V; Koivikko, Mika P; Koskinen, Seppo K

    2011-12-01

    Sports and recreational accidents involving critical areas of the body occur commonly in the general population. Reports on their demographics and recommendations for screening procedures are, however, few. To assess injuries of the craniofacial area, spine, and torso resulting from sports and recreational accidents with multidetector computed tomography (MDCT) as primary imaging method in a Level I trauma center. All emergency room CT requests over a time span of 105 months were reviewed retrospectively for trauma mechanism and injury. Patients were identified using an electronic picture archiving and communications system (PACS), and MDCT studies interpreted by two radiologists independently. Of a total of 5898 patients, 492 patients (301 boys/men, 191 girls/women, age range 2-76 years, mean 33.5 years, median 29.5 years) with sports or recreational accidents emerged. A total of 102 traumatic findings were diagnosed, thereof 72 (71%) serious. The three most commonly encountered serious injuries were intracranial injury, fractures of facial bones, and vertebral injuries. The three most common injury mechanisms were bicycling, horseback riding, and team ball sports. Patients from recreational activities were on average significantly younger (29.2 years) than those from sports accidents (36.9 years; P accidents presented with an overall incidence of 21%, of which 71% are serious. The most common mechanisms of injury were bicycling, horseback riding, and team ball sports. The largest incidence of serious injury involved bicycling. Because of the high probability of a serious injury and the high energies that are often involved in these accidents, we recommend ruling out of internal injury by MDCT as the primary imaging modality.

  1. MDCT assessment of CAD in type-2 diabetic subjects with diabetic neuropathy: the role of Charcot neuro-arthropathy

    International Nuclear Information System (INIS)

    Marano, Riccardo; Savino, Giancarlo; Merlino, Biagio; Pirro, Federica; Rutigliano, Claudia; Santangelo, Carolina; Minoiu, Aurelian Costin; Natale, Luigi; Bonomo, Lorenzo; Pitocco, Dario; Di Stasio, Enrico; Trani, Carlo

    2016-01-01

    To compare the CACS and CAD severity assessed by MDCT in neuropathic type-2 diabetic patients with and without Charcot-neuroarthropathy (CN). Thirty-four CN asymptomatic-patients and 36 asymptomatic-patients with diabetic-neuropathy (DN) without CN underwent MDCT to assess CACS and severity of CAD. Patients were classified as positive for significant CAD in presence of at least one stenosis >50 % on MDCT-coronary-angiography (MDCT-CA). Groups were matched for age, sex and traditional CAD risk-factors. The coronary-angiography (CA) was performed in all patients with at least a significant stenosis detected by MDCT-CA, both as reference and eventually as treatment. CN patients showed higher rates of significant CAD in comparison with DN subjects [p < 0.001], while non-significant differences were observed in CACS (p = 0.980). No significant differences were also observed in CACS distribution in all subjects for stenosis ≥/<50 % (p = 0.814), as well as in both groups (p = 0.661 and 0.559, respectively). The MDCT-CA showed an overall diagnostic-accuracy for significant CAD of 87 %. These preliminary data suggest that CN-patients have a higher prevalence of severe CAD in comparison with DN-patients, while coronary plaques do not exhibit an increased amount of calcium. MDCT may be helpful to assess the CV risk in such asymptomatic type-2-diabetic patients with autonomic-neuropathy. (orig.)

  2. MDCT assessment of CAD in type-2 diabetic subjects with diabetic neuropathy: the role of Charcot neuro-arthropathy

    Energy Technology Data Exchange (ETDEWEB)

    Marano, Riccardo; Savino, Giancarlo; Merlino, Biagio; Pirro, Federica; Rutigliano, Claudia; Santangelo, Carolina; Minoiu, Aurelian Costin; Natale, Luigi; Bonomo, Lorenzo [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Radiological Sciences - Institute of Radiology, Rome (Italy); Pitocco, Dario [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Internal Medicine, Rome (Italy); Di Stasio, Enrico [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Clinical Biochemistry, Rome (Italy); Trani, Carlo [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Cardiovascular Medicine - Institute of Cardiology, Rome (Italy)

    2016-03-15

    To compare the CACS and CAD severity assessed by MDCT in neuropathic type-2 diabetic patients with and without Charcot-neuroarthropathy (CN). Thirty-four CN asymptomatic-patients and 36 asymptomatic-patients with diabetic-neuropathy (DN) without CN underwent MDCT to assess CACS and severity of CAD. Patients were classified as positive for significant CAD in presence of at least one stenosis >50 % on MDCT-coronary-angiography (MDCT-CA). Groups were matched for age, sex and traditional CAD risk-factors. The coronary-angiography (CA) was performed in all patients with at least a significant stenosis detected by MDCT-CA, both as reference and eventually as treatment. CN patients showed higher rates of significant CAD in comparison with DN subjects [p < 0.001], while non-significant differences were observed in CACS (p = 0.980). No significant differences were also observed in CACS distribution in all subjects for stenosis ≥/<50 % (p = 0.814), as well as in both groups (p = 0.661 and 0.559, respectively). The MDCT-CA showed an overall diagnostic-accuracy for significant CAD of 87 %. These preliminary data suggest that CN-patients have a higher prevalence of severe CAD in comparison with DN-patients, while coronary plaques do not exhibit an increased amount of calcium. MDCT may be helpful to assess the CV risk in such asymptomatic type-2-diabetic patients with autonomic-neuropathy. (orig.)

  3. Head and neck imaging with MDCT

    International Nuclear Information System (INIS)

    Imhof, H.; Czerny, Chr.; Dirisamer, A.

    2003-01-01

    Multi-slice CT (MDCT) is rapidly becoming the new standard in radiological imaging. Although its advantages in cardiovascular, thoracic and abdominal imaging are evident, the extent of its usefulness for imaging the head and neck has yet to be clarified. Because of the shorter examination time motion artifacts are reduced, phonation-studies are possible. Due to the thin-slicing and nearly isotropic multiplanar reconstruction (MPR) examination in only one plane is necessary, saving both time and radiation exposure. The shorter examination requires the use of higher concentrated contrast medium (400 mg of iodine/ml). The use of such a contrast medium produces a higher degree of contrast enhancement and provides a 5-10% higher contrast between the surrounding normal and pathological tissue, but is more time critical. MPRs are easily done in any plane within seconds and enables also three-dimensional visualization, what helps in the use of minimal invasive therapy, training and teaching and provides a way of handling the hundreds of images acquired during scanning

  4. Feasibility and diagnostic accuracy of a low radiation exposure protocol for prospective ECG-triggering coronary MDCT angiography

    International Nuclear Information System (INIS)

    Pontone, G.; Andreini, D.; Bartorelli, A.L.; Bertella, E.; Mushtaq, S.; Foti, C.; Formenti, A.; Chiappa, L.; Annoni, A.; Cortinovis, S.; Baggiano, A.; Conte, E.; Bovis, F.; Veglia, F.; Ballerini, G.; Agostoni, P.; Fiorentini, C.; Pepi, M.

    2012-01-01

    Aim: To compare the feasibility, accuracy, and effective radiation dose (ED) of multidetector computed tomography (MDCT) in the detection of coronary artery disease using a combined ED-saving strategy including prospective electrocardiogram (ECG) triggering with a short x-ray window and a body mass index (BMI)-adapted imaging protocol using adaptive statistical iterative reconstruction (ASIR; group 1), in comparison with a prospective ECG triggering strategy alone (group 2). Materials and methods: One hundred and seventy patients scheduled for invasive coronary angiography (ICA) were evaluated. Fourteen patients were not eligible for MDCT. The remaining 156 patients were randomized to group 1 (78 patients) and group 2 (78 patients). Eight and 11 patients in groups 1 and 2, respectively, were excluded after randomization because the patients’ heart rates were >65 beats/min. MDCT images were assessed for feasibility, signal-to-noise ration (SNR), and contrast-to-noise ratio (CNR), accuracy in detection of coronary stenoses >50% versus ICA and for ED. Results: The feasibility, SNR, CNR, accuracy in a segment-based and patient-based model were similar in both groups (97 versus 95%, 14.5 ± 3.9 versus 14.2 ± 4.1, 16 ± 4.6 versus 16.5 ± 4.4, 95 versus 94% and 97 versus 99%, respectively). The ED in group 1 was 72% lower than in group 2 (2.1 ± 1.2 versus 7.5 ± 1.8 mSv, respectively; p < 0.01). Conclusions: The use of a multi-parametric ED saving protocol results in a significant reduction in ED without a negative impact on accuracy.

  5. Feasibility and diagnostic accuracy of a low radiation exposure protocol for prospective ECG-triggering coronary MDCT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Pontone, G., E-mail: gianluca.pontone@ccfm.it [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Andreini, D. [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Bartorelli, A.L. [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Department of Cardiovascular Sciences, University of Milan, Milan (Italy); Bertella, E.; Mushtaq, S.; Foti, C.; Formenti, A.; Chiappa, L.; Annoni, A.; Cortinovis, S.; Baggiano, A.; Conte, E.; Bovis, F.; Veglia, F.; Ballerini, G. [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Agostoni, P.; Fiorentini, C. [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Department of Cardiovascular Sciences, University of Milan, Milan (Italy); Pepi, M. [Centro Cardiologico Monzino, IRCCS, Milan (Italy)

    2012-03-15

    Aim: To compare the feasibility, accuracy, and effective radiation dose (ED) of multidetector computed tomography (MDCT) in the detection of coronary artery disease using a combined ED-saving strategy including prospective electrocardiogram (ECG) triggering with a short x-ray window and a body mass index (BMI)-adapted imaging protocol using adaptive statistical iterative reconstruction (ASIR; group 1), in comparison with a prospective ECG triggering strategy alone (group 2). Materials and methods: One hundred and seventy patients scheduled for invasive coronary angiography (ICA) were evaluated. Fourteen patients were not eligible for MDCT. The remaining 156 patients were randomized to group 1 (78 patients) and group 2 (78 patients). Eight and 11 patients in groups 1 and 2, respectively, were excluded after randomization because the patients' heart rates were >65 beats/min. MDCT images were assessed for feasibility, signal-to-noise ration (SNR), and contrast-to-noise ratio (CNR), accuracy in detection of coronary stenoses >50% versus ICA and for ED. Results: The feasibility, SNR, CNR, accuracy in a segment-based and patient-based model were similar in both groups (97 versus 95%, 14.5 {+-} 3.9 versus 14.2 {+-} 4.1, 16 {+-} 4.6 versus 16.5 {+-} 4.4, 95 versus 94% and 97 versus 99%, respectively). The ED in group 1 was 72% lower than in group 2 (2.1 {+-} 1.2 versus 7.5 {+-} 1.8 mSv, respectively; p < 0.01). Conclusions: The use of a multi-parametric ED saving protocol results in a significant reduction in ED without a negative impact on accuracy.

  6. Visualization of subtle temporal bone structures. Comparison of cone beam CT and MDCT

    International Nuclear Information System (INIS)

    Pein, M.K.; Plontke, S.K.; Brandt, S.; Koesling, S.

    2014-01-01

    The purpose of this study was to compare the visualization of subtle, non-pathological temporal bone structures on cone beam computed tomography (CBCT) and multi-detector computed tomography (MDCT) in vivo. Temporal bone studies of images from 38 patients archived in the picture archiving and communication system (PACS) were analyzed (slice thickness MDCT 0.6 mm and CBCT 0.125 mm) of which 23 were imaged by MDCT and 15 by CBCT using optimized standard protocols. Inclusion criteria were normal radiological findings, absence of previous surgery and anatomical variants. Images were evaluated blind by three trained observers. Using a five-point scale the visualization of ten subtle structures of the temporal bone was analyzed. Subtle middle ear structures showed a tendency to be more easily distinguishable by CBCT with significantly better visualization of the tendon of the stapedius muscle and the crura of the stapes on CBCT (p = 0.003 and p = 0.033, respectively). In contrast, inner ear components, such as the osseus spiral lamina and the modiolus tended to be better detectable on MDCT, showing significant differences for the osseous spiral lamina (p = 0.001). The interrater reliability was 0.73 (Cohen's kappa coefficient) and intraobserver reliability was 0.89. The use of CBCT and MDCT allows equivalent and excellent imaging results if optimized protocols are chosen. With both imaging techniques subtle temporal bone structures could be visualized with a similar degree of definition. In vivo differences do not seem to be as large as suggested in several previous studies. (orig.) [de

  7. Chronic mitral regurgitation detected on cardiac MDCT: differentiation between functional and valvular aetiologies.

    LENUS (Irish Health Repository)

    Killeen, Ronan P

    2012-02-01

    OBJECTIVE: To determine whether cardiac computed tomography (MDCT) can differentiate between functional and valvular aetiologies of chronic mitral regurgitation (MR) compared with echocardiography (TTE). METHODS: Twenty-seven patients with functional or valvular MR diagnosed by TTE and 19 controls prospectively underwent cardiac MDCT. The morphological appearance of the mitral valve (MV) leaflets, MV geometry, MV leaflet angle, left ventricular (LV) sphericity and global\\/regional wall motion were analysed. The coronary arteries were evaluated for obstructive atherosclerosis. RESULTS: All control and MR cases were correctly identified by MDCT. Significant differences were detected between valvular and control groups for anterior leaflet length (30 +\\/- 7 mm vs. 22 +\\/- 4 mm, P < 0.02) and thickness (3.0 +\\/- 1 mm vs. 2.2 +\\/- 1 mm, P < 0.01). High-grade coronary stenosis was detected in all patients with functional MR compared with no controls (P < 0.001). Significant differences in those with\\/without MV prolapse were detected in MV tent area (-1.0 +\\/- 0.6 mm vs. 1.3 +\\/- 0.9 mm, P < 0.0001) and MV tent height (-0.7 +\\/- 0.3 mm vs. 0.8 +\\/- 0.8 mm, P < 0.0001). Posterior leaflet angle was significantly greater for functional MR (37.9 +\\/- 19.1 degrees vs. 22.9 +\\/- 14 degrees , P < 0.018) and less for valvular MR (0.6 +\\/- 35.5 degrees vs. 22.9 +\\/- 14 degrees, P < 0.017). Sensitivity, specificity, and positive and negative predictive values of MDCT were 100%, 95%, 96% and 100%. CONCLUSION: Cardiac MDCT allows the differentiation between functional and valvular causes of MR.

  8. Multidetector computed tomography (MDCT) evaluation of myocardial viability: intraindividual comparison of monomeric vs. dimeric contrast media in a rabbit model

    Energy Technology Data Exchange (ETDEWEB)

    Mahnken, Andreas H. [RWTH Aachen University, Department of Diagnostic Radiology, Aachen (Germany)]|[RWTH Aachen University, Applied Medical Engineering, Helmholtz Institute, Aachen (Germany)]|[University Hospital, RWTH Aachen University, Department of Diagnostic Radiology, Aachen (Germany); Jost, Gregor; Sieber, Martin; Seidensticker, Peter R.; Pietsch, Hubertus [Bayer-Schering Pharma AG, Berlin (Germany); Bruners, Philipp [RWTH Aachen University, Department of Diagnostic Radiology, Aachen (Germany)]|[RWTH Aachen University, Applied Medical Engineering, Helmholtz Institute, Aachen (Germany); Guenther, Rolf W. [RWTH Aachen University, Department of Diagnostic Radiology, Aachen (Germany)

    2009-02-15

    To evaluate the influence of different types of iodinated contrast media on the assessment of myocardial viability, acute myocardial infarction (MI) was surgically induced in six rabbits. Over a period of 45 min, contrast-enhanced cardiac MDCT (64 x 0.6 mm, 80 kV, 680mAs{sub eff.}) was repeatedly performed using a contrast medium dose of 600 mg iodine/kg body weight. Animals received randomized iopromide 300 and iodixanol 320, respectively. Attenuation values of healthy and infarcted myocardium were measured. The size of MI was computed and compared with nitroblue tetrazolium (NBT)-stained specimen. The highest attenuation differences between infarcted and healthy myocardium occurred during the arterial phase with 140.0{+-}3.5 HU and 141.0{+-}2.2 HU for iopromide and iodixanol, respectively. For iodixanol the highest attenuation difference on delayed contrast-enhanced images was achieved 3 min post injection (73.5 HU). A slightly higher attenuation difference was observed for iopromide 6 min after contrast medium injection (82.2 HU), although not statistically significant (p=0.6437). Mean infarct volume as measured by NBT staining was 33.5%{+-}13.6%. There was an excellent agreement of infarct sizes among NBT-, iopromide- and iodixanol-enhanced MDCT with concordance-correlation coefficients ranging from {rho}{sub (c)=} 0.9928-0.9982. Iopromide and iodixanol both allow a reliable assessment of MI with delayed contrast-enhanced MDCT. (orig.)

  9. Novel technique for addressing streak artifact in gated dual-source MDCT angiography utilizing ECG-editing

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Laura T.; Boll, Daniel T. [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC (United States)

    2008-11-15

    Streak artifact is an important source of image degradation in computed tomographic imaging. In coronary MDCT angiography, streak artifact from pacemaker leads in the SVC can render segments of the right coronary artery uninterpretable. With current technology in clinical practice, there is no effective way to eliminate streak artifact in coronary MDCT angiography entirely. We propose a technique to minimize the impact of streak artifact in retrospectively gated coronary MDCT angiography by utilizing small shifts in the reconstruction window. In our experience, previously degraded portions of the coronary vasculature were able to be well evaluated using this technique. (orig.)

  10. Expiratory timing in obstructive sleep apnoeas.

    Science.gov (United States)

    Cibella, F; Marrone, O; Sanci, S; Bellia, V; Bonsignore, G

    1990-03-01

    Diaphragmatic electromyogram was recorded during NREM sleep in 4 patients affected by obstructive sleep apnoea (OSA) syndrome in order to evaluate the behaviour of expiratory time (TE) in the course of the obstructive apnoea-ventilation cycle. The two components of TE, i.e. time of post-inspiratory inspiratory activity (TPIIA) and time of expiratory phase 2 (TE2) were separately analysed. TPIIA showed a short duration, with only minor variations, within the apnoea, while its duration was more variable and longer in the interapnoeic periods: the longest TPIIA values were associated with the highest inspiratory volumes in the same breaths. This behaviour seemed regulated according to the need of a more or less effective expiratory flow braking, probably as a result of pulmonary stretch receptors discharge. Conversely TE2 showed a continuous gradual modulation, progressively increasing in the pre-apnoeic period, decreasing during the apnoea and increasing in the post-apnoeic period: these TE2 variations seemed related to oscillations in chemical drive. These data show that TE in the obstructive apnoea-ventilation cycle results from a different modulation in its two components and suggest that both mechanical and chemical influences play a role in its overall duration.

  11. Positive end-expiratory pressure improves survival in a rodent model of cardiopulmonary resuscitation using high-dose epinephrine.

    LENUS (Irish Health Repository)

    McCaul, Conán

    2009-10-01

    Multiple interventions have been tested in models of cardiopulmonary resuscitation (CPR) to optimize drug use, chest compressions, and ventilation. None has studied the effects of positive end-expiratory pressure (PEEP) on outcome. We hypothesized that because PEEP can reverse pulmonary atelectasis, lower pulmonary vascular resistance, and potentially improve cardiac output, its use during CPR would increase survival.

  12. Effects of positive end-expiratory pressure on renal function.

    Science.gov (United States)

    Järnberg, P O; de Villota, E D; Eklund, J; Granberg, P O

    1978-01-01

    The effects were studied positive end-expiratory pressure (PEEP) on renal function in eight patients with acute respiratory failure, requiring mechanical ventilation. On application of PEEP + 10 cm H2O, central venous pressure increased, systolic blood pressure decreased, urine flow and PAH-clearance were reduced, while inulin clearance remained stable. There was a marked increase in fractional sodium reabsorption and a concurrent decrease in fractional osmolal excretion. Fractional free-water clearance and the ratio UOsm/POsm did change.

  13. Baseline MDCT findings after prosthetic heart valve implantation provide important complementary information to echocardiography for follow-up purposes

    Energy Technology Data Exchange (ETDEWEB)

    Sucha, Dominika; Mali, Willem P.T.M.; Habets, Jesse [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Chamuleau, Steven A.J. [University Medical Center Utrecht, Department of Cardiology, Utrecht (Netherlands); Symersky, Petr [VU Medical Center, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); Meijs, Matthijs F.L. [Thoraxcentrum Twente, Medisch Spectrum Twente, Department of Cardiology, Enschede (Netherlands); Brink, Renee B.A. van den [Academic Medical Center, Department of Cardiology, Amsterdam (Netherlands); Mol, Bas A.J.M. de [Academic Medical Center, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); Herwerden, Lex A. van [University Medical Center Utrecht, Department of Cardiothoracic Surgery, Utrecht (Netherlands); Budde, Ricardo P.J. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands)

    2016-04-15

    Recent studies have proposed additional multidetector-row CT (MDCT) for prosthetic heart valve (PHV) dysfunction. References to discriminate physiological from pathological conditions early after implantation are lacking. We present baseline MDCT findings of PHVs 6 weeks post implantation. Patients were prospectively enrolled and TTE was performed according to clinical guidelines. 256-MDCT images were systematically assessed for leaflet excursions, image quality, valve-related artefacts, and pathological and additional findings. Forty-six patients were included comprising 33 mechanical and 16 biological PHVs. Overall, MDCT image quality was good and relevant regions remained reliably assessable despite mild-moderate PHV-artefacts. MDCT detected three unexpected valve-related pathology cases: (1) prominent subprosthetic tissue, (2) pseudoaneurysm and (3) extensive pseudoaneurysms and valve dehiscence. The latter patient required valve surgery to be redone. TTE only showed trace periprosthetic regurgitation, and no abnormalities in the other cases. Additional findings were: tilted aortic PHV position (n = 3), pericardial haematoma (n = 3) and pericardial effusion (n = 3). Periaortic induration was present in 33/40 (83 %) aortic valve patients. MDCT allowed evaluation of relevant PHV regions in all valves, revealed baseline postsurgical findings and, despite normal TTE findings, detected three cases of unexpected, clinically relevant pathology. (orig.)

  14. Role of MDCT angiography in the preoperative evaluation of anomalous pulmonary venous connection associated with complex cardiac abnormality

    International Nuclear Information System (INIS)

    Liu Jingzhe; Wu Qingyu; Xu Yufeng; Bai Yan; Liu Zhibo; Li Hongyin; Zhu Jiemin

    2012-01-01

    Objectives: To evaluate the diagnostic accuracy of MDCT in patients with APVC associated with complex cardiac abnormality. Materials and methods: The clinical and imaging data of 39 patients with APVC confirmed by surgery were retrospectively reviewed. According to accompanied cardiac malformations, patients with APVC were classified as isolated and complex group. Using surgical findings as the reference standard, diagnostic agreement of MDCT, TTE (transthoracic echocardiography) and cardiac catheterization for detection of APVC were calculated. Results: At surgery, 27 patients were considered as complex APVCs. MDCT correctly diagnosed APVC in all patients and the diagnostic agreements between MDCT and surgery were both 100% in isolated and complex groups. All 5 APVCs which could not be detected at cardiac catheterization were in complex group, and the diagnostic agreements were 100% and 76.2% in isolated and complex groups, respectively. At TTE, eight of nine disagreed patients were complex cases. The diagnostic agreements of TTE were 91.7% and 66.7% in isolated and complex groups, respectively. The dysmorphic pulmonary veins were identified in 11 patients by MDCT. Conclusions: MDCT is superior to catheterization and TTE in evaluation of APVC associated with complex cardiac defects.

  15. Myocardial bridging as evaluated by 16 row MDCT

    International Nuclear Information System (INIS)

    Canyigit, Murat; Hazirolan, Tuncay; Karcaaltincaba, Musturay; Dagoglu, Merve Gulbiz; Akata, Deniz; Aytemir, Kudret; Oto, Ali; Balkanci, Ferhun; Akpinar, Erhan; Besim, Aytekin

    2009-01-01

    Purpose: The purpose of this study is to find out the prevalence, appearance and clinical symptoms of myocardial bridging (MB) by MDCT coronary angiography (CTA). Materials and methods: A total of 280 (50 females) consecutive patients followed with coronary artery disease or postoperative stent and bypass control, underwent CTA performed by 16-MDCT scanner between January 2006 and April 2006. Short axis multiplanar reformatted images were evaluated. MBs were classified as complete and incomplete bridges with respect to continuity of the myocardium over the tunneled segment of left anterior descending artery (LAD) in interventricular groove and the cut-off value is 1.3 mm. Patients diagnosed with MB on CTA who had prior catheter angiography studies were re-evaluated for the presence of MB. Results: One hundred and twenty MBs [98 (81.6%) on LAD, 2 (1.6%) on diagonal branch, 11 (9.1%) on obtuse marginal, 4 (3.3%) on right coronary artery, 5 (4.1%) on ramus intermedius artery] were detected in 108 (38.5%) patients. Eighty-five (70.8%) of bridged segments in 79 (28.2%) patients were complete and the rest [35 (29.2%) in 34 (12.1%) patients] were incomplete. In 12 patients two MBs (either on different arteries or on the same artery) were detected. The length of bridged segments in patients with complete and incomplete MBs varied between 4-50.9 mm (mean 18 mm) and 4-37.3 mm (mean 13.6 mm), respectively, and the depth of myocardium over the artery ranged between 1-6.4 mm (mean 2.3 mm) and 1-1.2 mm (mean 1 mm), respectively. Thirty (27.7%) out of 108 patients, in whom MB was detected on CTA, were found to have correlative catheter angiography studies, retrospectively and MB was detected only in 4 (13.3%) out of 30 patients. Conclusion: MDCT coronary angiography is a non-invasive, efficient method in the diagnosis of MB avoiding the procedural risks that catheter angiography carries. MDCT coronary angiography allows direct visualization of the bridge itself and may thus give

  16. Utility of 64-row MDCT in assessment of neonates with congenital EA and distal TEF

    Directory of Open Access Journals (Sweden)

    Hosam El-Deen Galal Mohamed El-Malah

    2015-12-01

    Conclusion: Preoperative MDCT scan with MPVR, 3D TL-VR of 64-row MDCT which is a noninvasive technique could provide more accurate information about the assessment of the origin of the fistula, the distal esophageal pouches and inter-pouch distance in neonates with EA and distal TEF.

  17. Peak Expiratory Flow Rate In Cigarette Smokers | Ukoli | Highland ...

    African Journals Online (AJOL)

    Objective: To compare lung function between smokers and non-smokers using Peak Expiratory Flow Rate (PEFR). Methods: This study examines the peak expiratory flow rate (PEFR) of three hundred and forty cigarette smokers, age and sex-matched with PEFR of equal number of non-smokers. Results: The mean PEFR of ...

  18. Superoxide dismutase levels and peak expiratory flow in asthmatic children

    Directory of Open Access Journals (Sweden)

    Arie Kurniasih

    2016-11-01

    Full Text Available Background Asthma is a chronic inflammatory process which involve variety of cells such as inflammatory mediators, reactive oxygen species (ROS, and cytokines. The inflammatory process would be exacerbated in the presence of oxidative stress. Superoxide dismutase (SOD is the first important enzyme to protect the respiratory tract against oxidative stress. The decreased of SOD has a correlation with increased of airway obstruction and bronchospasm. Objective To assess for a correlation between superoxide dismutase (SOD levels and peak expiratory flow, as well as to determine the impact of SOD levels for predicting asthma attacks. Methods We conducted a prospective cohort study at Dr. Sardjito Hospital, Yogyakarta, between February and April 2011 involving asthmatic children aged 5-18 years. Subjects’ serum SOD levels and peak expiratory flow were measured at the same time point. We then performed a prospective study following up on the same subjects to find out if they had a recurrent asthma attack within one month of the tests. We also reassessed their peak expiratory flow one month after blood specimens were obtained. Results Thirty-nine patients were enrolled in this study. There was no significant correlation between SOD level and peak expiratory flow [r=0.289; 95%CI -0.025 to 0.47; P=0.074]. However, older age was significantly associated with higher peak expiratory flow (=0.5; 95%CI 3.10 to 11.57; P=0.01. Lower levels of SOD increased the risk of asthma attacks in a month following the initial measurements (RR=5.5; 95%CI 1.6 to 18.9; P=0.009. Conclusion Superoxide dismutase (SOD level is not significantly associated with peak expiratory flow. However, we find a relationship between older age and higher peak expiratory flow and a relationship between lower SOD levels and risk of asthma attacks within one month following the tests.

  19. Physiological techniques for detecting expiratory flow limitation during tidal breathing

    Directory of Open Access Journals (Sweden)

    N.G. Koulouris

    2011-09-01

    Full Text Available Patients with severe chronic obstructive pulmonary disease (COPD often exhale along the same flow–volume curve during quiet breathing as they do during the forced expiratory vital capacity manoeuvre, and this has been taken as an indicator of expiratory flow limitation at rest (EFLT. Therefore, EFLT, namely attainment of maximal expiratory flow during tidal expiration, occurs when an increase in transpulmonary pressure causes no increase in expiratory flow. EFLT leads to small airway injury and promotes dynamic pulmonary hyperinflation, with concurrent dyspnoea and exercise limitation. In fact, EFLT occurs commonly in COPD patients (mainly in Global Initiative for Chronic Obstructive Lung Disease III and IV stage, in whom the latter symptoms are common, but is not exclusive to COPD, since it can also be detected in other pulmonary and nonpulmonary diseases like asthma, acute respiratory distress syndrome, heart failure and obesity, etc. The existing up to date physiological techniques of assessing EFLT are reviewed in the present work. Among the currently available techniques, the negative expiratory pressure has been validated in a wide variety of settings and disorders. Consequently, it should be regarded as a simple, noninvasive, practical and accurate new technique.

  20. Comparison radiation dose of Z-axis automatic tube current modulation technique with fixed tube current multi-detector row CT scanning of lower extremity venography

    International Nuclear Information System (INIS)

    Yoo, Beong Gyu; Kweon, Dae Cheol; Lee, Jong Seok; Jang, Keun Jo; Jeon, Sang Hwan; Kim, Yong Soo

    2007-01-01

    Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of Multi-Detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, 70∼450 mA). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, Z-axis modulation resulted in reduction of CTDIvol (range, -6.5%∼-35.6%) and DLP (range,-0.2%∼-20.2%). Compared with manually selected fixed tube current, Z-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography

  1. Radiation-induced temporary hair loss as a radiation damage only occurring in patients who had the combination of MDCT and DSA

    International Nuclear Information System (INIS)

    Imanishi, Yoshimasa; Fukui, Atsushi; Itoh, Daisuke; Nozaki, Kyouko; Nakaji, Shunsuke; Ishizuka, Kumiko; Nakajima, Yasuo; Niimi, Hiroshi; Tabata, Hitoshi; Arima, Shiro; Furuya, Yu; Uzura, Masahiko; Takahama, Hideto; Hashizume, Suzuo

    2005-01-01

    As imaging technologies become increasingly advanced, it is possible to obtain detailed morphological information as well as functional imaging data. In some imaging technologies, the radiation dose increases with the ability to obtain better images or more detailed information. We encountered three cases of temporary bandage-shaped hair loss, which was caused by perfusion studies of the head by multi-detector row computed tomography (MDCT) for evaluation of cerebral blood flow in patients with vascular disorders. In all three patients with temporary hair loss, two angiographies of the head had been performed in the period of serial CT examinations. This suggested the possibility that radiation exposure from angiography performed in serial examinations, combined with the perfusion studies of the head with MDCT, played an important role in this temporary, bandage-shaped hair loss. Radiologists should be aware that a cumulative or multiplier effect of radiation exposure from multiple diagnostic techniques may result in hair loss and other types of radiation complications. (orig.)

  2. Evaluation of a dedicated MDCT protocol using iterative image reconstruction after cervical spine trauma

    International Nuclear Information System (INIS)

    Geyer, L.L.; Körner, M.; Hempel, R.; Deak, Z.; Mueck, F.G.; Linsenmaier, U.; Reiser, M.F.; Wirth, S.

    2013-01-01

    Aim: To evaluate radiation exposure for 64-row computed tomography (CT) of the cervical spine comparing two optimized protocols using filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR), respectively. Materials and methods: Sixty-seven studies using FBP (scanner 1) were retrospectively compared with 80 studies using ASIR (scanner 2). The key scanning parameters were identical (120 kV dose modulation, 64 × 0.625 mm collimation, pitch 0.531:1). In protocol 2, the noise index (NI) was increased from 5 to 25, and ASIR and the high-definition (HD) mode were used. The scan length, CT dose index (CTDI), and dose–length product (DLP) were recorded. The image quality was analysed subjectively by using a three-point scale (0; 1; 2), and objectively by using a region of interest (ROI) analysis. Mann–Whitney U and Wilcoxon's test were used. Results: In the FBP group, the mean CTDI was 21.43 mGy, mean scan length 186.3 mm, and mean DLP 441.15 mGy cm. In the ASIR group, the mean CTDI was 9.57 mGy, mean scan length 195.21 mm, and mean DLP 204.23 mGy cm. The differences were significant for CTDI and DLP (p 0.05). The estimated mean effective dose decreased from 2.38 mSv (FBP) to 1.10 mSv (ASIR). Conclusion: The radiation dose of 64-row MDCT can be reduced to a level comparable to plain radiography without loss of subjective image quality by implementation of ASIR in a dedicated cervical spine trauma protocol. These results might contribute to an improved relative risk-to-benefit ratio and support the justification of CT as a first-line imaging tool to evaluate cervical spine trauma

  3. What's in a name? Expiratory tracheal narrowing in adults explained

    International Nuclear Information System (INIS)

    Leong, P.; Bardin, P.G.; Lau, K.K.

    2013-01-01

    Tracheomalacia, tracheobronchomalacia, and excessive dynamic airway collapse are all terms used to describe tracheal narrowing in expiration. The first two describe luminal reduction from cartilage softening and the latter refers to luminal reduction from exaggerated posterior membrane movement. Expiratory tracheal narrowing is a frequent occurrence that can cause symptoms of airway obstruction, such as dyspnoea, wheeze, and exercise intolerance. The accurate diagnosis and quantification of expiratory tracheal narrowing has important aetiological, therapeutic, and prognostic implications. The reference standard for diagnosis has traditionally been bronchoscopy; however, this method has significant limitations. Expiratory tracheal disorders are readily detected by four-dimensional dynamic volume multidetector computed tomography (4D-CT), an emerging, non-invasive method that will potentially enable detection and quantification of these conditions. This review discusses the morphological forms of expiratory tracheal narrowing and demonstrates the utility of 4D-CT in the diagnosis, quantification, and treatment of these important conditions

  4. Comparison between MDCT and Grayscale IVUS in a Quantitative Analysis of Coronary Lumen in Segments with or without Atherosclerotic Plaques

    Energy Technology Data Exchange (ETDEWEB)

    Falcão, João L. A. A.; Falcão, Breno A. A. [Heart Institute (InCor), University of São Paulo Medical School (USP), São Paulo, SP (Brazil); Gurudevan, Swaminatha V. [Cedars-Sinai Heart Institute, Los Angeles, California, USA (United States); Campos, Carlos M.; Silva, Expedito R.; Kalil-Filho, Roberto; Rochitte, Carlos E.; Shiozaki, Afonso A.; Coelho-Filho, Otavio R.; Lemos, Pedro A. [Heart Institute (InCor), University of São Paulo Medical School (USP), São Paulo, SP (Brazil)

    2015-04-15

    The diagnostic accuracy of 64-slice MDCT in comparison with IVUS has been poorly described and is mainly restricted to reports analyzing segments with documented atherosclerotic plaques. We compared 64-slice multidetector computed tomography (MDCT) with gray scale intravascular ultrasound (IVUS) for the evaluation of coronary lumen dimensions in the context of a comprehensive analysis, including segments with absent or mild disease. The 64-slice MDCT was performed within 72 h before the IVUS imaging, which was obtained for at least one coronary, regardless of the presence of luminal stenosis at angiography. A total of 21 patients were included, with 70 imaged vessels (total length 114.6 ± 38.3 mm per patient). A coronary plaque was diagnosed in segments with plaque burden > 40%. At patient, vessel, and segment levels, average lumen area, minimal lumen area, and minimal lumen diameter were highly correlated between IVUS and 64-slice MDCT (p < 0.01). However, 64-slice MDCT tended to underestimate the lumen size with a relatively wide dispersion of the differences. The comparison between 64-slice MDCT and IVUS lumen measurements was not substantially affected by the presence or absence of an underlying plaque. In addition, 64-slice MDCT showed good global accuracy for the detection of IVUS parameters associated with flow-limiting lesions. In a comprehensive, multi-territory, and whole-artery analysis, the assessment of coronary lumen by 64-slice MDCT compared with coronary IVUS showed a good overall diagnostic ability, regardless of the presence or absence of underlying atherosclerotic plaques.

  5. MDCT arthrography of the wrist: Diagnostic accuracy and indications

    International Nuclear Information System (INIS)

    De Filippo, Massimo; Pogliacomi, Francesco; Bertellini, Annalisa; Araoz, Philip A.; Averna, Raffaele; Sverzellati, Nicola; Ingegnoli, Anna; Corradi, Maurizio; Costantino, Cosimo; Zompatori, Maurizio

    2010-01-01

    Purpose: To evaluate the diagnostic accuracy and indications of arthrography with Multidetector Computed Tomography (arthro-MDCT) of the wrist in patients with absolute or relative contraindications to magnetic resonance imaging (MRI) studies and in patients with periarticular metal implants using diagnostic arthroscopy as the gold standard. Materials and methods: After intra-articular injection of iodixanol and volumetric acquisition, 43 wrists in patients of both genders (18 females, 25 males, age range 32-60 years) were examined with a 16-detector-row CT scanner. Fifteen patients had prior wrist surgery. The patients had arthralgia, degenerative and traumatic arthropathies as well as limited range of motion, but no radiologically detected fractures. All examinations were interpreted by two experienced musculoskeletal radiologists. The findings were compared with arthroscopic findings carried out within 28 days of the CT study. Results: In non-operated and operated wrists the comparison between arthro-MDCT and arthroscopy showed sensitivity, specificity and accuracy ranging between 92% and 94% for triangular fibrocartilage complex (TFCC), between 80% and 100% for intrinsic ligaments located within the proximal carpal compartment, and between 94% and 100% for articular cartilage. Inter-observer agreement between two radiologists, in the evaluation of all types of lesions, was almost perfect (k = 0.96) and statistically significant (p < 0.05). Conclusions: Arthro-MDCT of the wrist provides an accurate diagnosis to identify chondral, fibrocartilaginous and intra-articular ligament lesions in patients who cannot be evaluated by MRI, and in post-surgical patients.

  6. MDCT arthrography of the wrist: Diagnostic accuracy and indications

    Energy Technology Data Exchange (ETDEWEB)

    De Filippo, Massimo [Department of Clinical Sciences, Section of Radiological Sciences, University of Parma, Parma Hospital, Via Gramsci, 14, 43100 Parma (Italy)], E-mail: massimo.defilippo@unipr.it; Pogliacomi, Francesco [Orthopaedics, Traumatology and Functional Rehabilitation Unit, Department of Surgical Sciences, University of Parma, Parma Hospital, Via Gramsci 14, 43100 Parma (Italy); Bertellini, Annalisa [Department of Clinical Sciences, Section of Radiological Sciences, University of Parma, Parma Hospital, Via Gramsci, 14, 43100 Parma (Italy); Araoz, Philip A. [Department of Radiology, Division of Biostatistics, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (United States); Averna, Raffaele; Sverzellati, Nicola; Ingegnoli, Anna [Department of Clinical Sciences, Section of Radiological Sciences, University of Parma, Parma Hospital, Via Gramsci, 14, 43100 Parma (Italy); Corradi, Maurizio; Costantino, Cosimo [Orthopaedics, Traumatology and Functional Rehabilitation Unit, Department of Surgical Sciences, University of Parma, Parma Hospital, Via Gramsci 14, 43100 Parma (Italy); Zompatori, Maurizio [Department of Radiological and Histopathological Sciences, Policlinic S.Orsola-Malpighi, University of Bologna, Via Massarenti 9, 40138 Bologna (Italy)

    2010-04-15

    Purpose: To evaluate the diagnostic accuracy and indications of arthrography with Multidetector Computed Tomography (arthro-MDCT) of the wrist in patients with absolute or relative contraindications to magnetic resonance imaging (MRI) studies and in patients with periarticular metal implants using diagnostic arthroscopy as the gold standard. Materials and methods: After intra-articular injection of iodixanol and volumetric acquisition, 43 wrists in patients of both genders (18 females, 25 males, age range 32-60 years) were examined with a 16-detector-row CT scanner. Fifteen patients had prior wrist surgery. The patients had arthralgia, degenerative and traumatic arthropathies as well as limited range of motion, but no radiologically detected fractures. All examinations were interpreted by two experienced musculoskeletal radiologists. The findings were compared with arthroscopic findings carried out within 28 days of the CT study. Results: In non-operated and operated wrists the comparison between arthro-MDCT and arthroscopy showed sensitivity, specificity and accuracy ranging between 92% and 94% for triangular fibrocartilage complex (TFCC), between 80% and 100% for intrinsic ligaments located within the proximal carpal compartment, and between 94% and 100% for articular cartilage. Inter-observer agreement between two radiologists, in the evaluation of all types of lesions, was almost perfect (k = 0.96) and statistically significant (p < 0.05). Conclusions: Arthro-MDCT of the wrist provides an accurate diagnosis to identify chondral, fibrocartilaginous and intra-articular ligament lesions in patients who cannot be evaluated by MRI, and in post-surgical patients.

  7. Potential contribution of multiplanar reconstruction (MPR) to computer-aided detection of lung nodules on MDCT

    International Nuclear Information System (INIS)

    Matsumoto, Sumiaki; Ohno, Yoshiharu; Yamagata, Hitoshi; Nogami, Munenobu; Kono, Atsushi; Sugimura, Kazuro

    2012-01-01

    Purpose: To evaluate potential benefits of using multiplanar reconstruction (MPR) in computer-aided detection (CAD) of lung nodules on multidetector computed tomography (MDCT). Materials and methods: MDCT datasets of 60 patients with suspected lung nodules were retrospectively collected. Using “second-read” CAD, two radiologists (Readers 1 and 2) independently interpreted these datasets for the detection of non-calcified nodules (≥4 mm) with concomitant confidence rating. They did this task twice, first without MPR (using only axial images), and then 4 weeks later with MPR (using also coronal and sagittal MPR images), where the total reading time per dataset, including the time taken to assess the detection results of CAD software (CAD assessment time), was recorded. The total reading time and CAD assessment time without MPR and those with MPR were statistically compared for each reader. The radiologists’ performance for detecting nodules without MPR and the performance with MPR were compared using jackknife free-response receiver operating characteristic (JAFROC) analysis. Results: Compared to the CAD assessment time without MPR (mean, 69 s and 57 s for Readers 1 and 2), the CAD assessment time with MPR (mean, 46 s and 45 s for Readers 1 and 2) was significantly reduced (P < 0.001). For Reader 1, the total reading time was also significantly shorter in the case with MPR. There was no significant difference between the detection performances without MPR and with MPR. Conclusion: The use of MPR has the potential to improve the workflow in CAD of lung nodules on MDCT.

  8. Study on children patient dose in single-detector and multi-detector row helical computed tomography

    International Nuclear Information System (INIS)

    Lu Heqing; Zhu Guoying; Zhuo Weihai; Liu Haikuan; Guo Changyi

    2008-01-01

    Objective: To study and evaluate the radiation dose of children patient in single-detector and multi-detector row helical CT scan. Methods: The head and body CT dose index of 21 CT scanners were tested. Then the values of CTDI w , CTDI vol and DLP were calculated combining with the parameters of routine head and chest scan for children of 0-1 year old group, 5 years old group, 10 years old group and adults. The effective doses of children of every age group and adults in routine head and chest scan were subsequently estimated from effective dose per DLP by age and the calculated values of DLP. Results: CTDI per mAs is greater in the head than that in the body. In head routine scan, the effective doses of 0-1 year old group,5 years old group and 10 year old group were 2.2, 1.3 and 1.1 mSv, respectively. In chest routine scan, the effective doses of 0-1 year old group,5 years old group and 10 years old group were 5.3, 3.1 and 3.4 mSv, respectively. Effective doses to children per mAs are equally 1.8 times higher than corresponding values for adults. The CTDI vol , DLP and effective dose to children in head routine scan for MDCT were greater those that for single-detector CT and dual- detector CT. The CTDI vol , DLP and effective dose to children in chest routine scan for MDCT and dual-detector row CT were smaller than that for single-detector row CT. Conclusions: Children me more radiation risk in CT examination as compared with adults. So we should strictly abide by justification of children CT examination, and optimize the parameters of CT scan rationally in order to reduce the radiation dose to children patient as much as possible. (authors)

  9. MDCT imaging of post interventional liver: a pictorial essay

    International Nuclear Information System (INIS)

    Romano, Stefania; Tortora, Giovanni; Scaglione, Mariano; Lassandro, Francesco; Guidi, Guido; Grassi, Roberto; Romano, Luigia

    2005-01-01

    In this pictorial essay, we consider the post operative MDCT findings after liver resection, transplantation, surgical managed major trauma and radiofrequency ablation of focal lesions. Common complications such as fluid collections, hemorrhage, biloma, vascular disease, hematoma, abscesses will be also considered

  10. Cost-Effectiveness Analysis (CEA) of Intravenous Urography (IVU) and Unenhanced Multidetector Computed Tomography (MDCT) for Initial Investigation of Suspected Acute Ureterolithiasis

    International Nuclear Information System (INIS)

    Eikefjord, E.; Askildsen, J.E.; Roervik, J.

    2008-01-01

    Background: It is important to compare the cost and effectiveness of multidetector computed tomography (MDCT) and intravenous urography (IVU) to determine the most cost-effective alternative for the initial investigation of acute ureterolithiasis. Purpose: To analyze the task-specific variable costs combined with the diagnostic effect of MDCT and IVU for patients with acute flank pain, and to determine which is most cost effective. Material and Methods: 119 patients with acute flank pain suggestive of stone disease (ureterolithiasis) were examined by both MDCT and IVU. Variable costs related to medical equipment, consumption material, equipment control, and personnel were calculated. The diagnostic effect was assessed. Results: The variable costs of MDCT versus IVU were EUR 32 and EUR 117, respectively. This significant difference was mainly due to savings in examination time, higher annual examination frequency, lower material costs, and no use of contrast media. As for diagnostic effect, MDCT proved considerably more accurate in the diagnosis of stone disease than IVU and markedly more accurate concerning differential diagnoses. Conclusion: MDCT had lower differential costs and a higher capacity to determine correctly stone disease and differential diagnoses, as compared to IVU, in patients with acute flank pain. Consequently, MDCT is a dominant alternative to IVU when evaluated exclusively from a cost-effective perspective

  11. Diagnostic accuracy of C-arm CT during selective transcatheter angiography for hepatocellular carcinoma: comparison with intravenous contrast-enhanced, biphasic, dynamic MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Higashihara, Hiroki; Osuga, Keigo; Onishi, Hiromitsu; Nakamoto, Atsushi; Tsuboyama, Takahiro; Maeda, Noboru; Hori, Masatoshi; Kim, Tonsok; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan)

    2012-04-15

    This study was aimed to compare the accuracy, sensitivity, and positive predictive value of C-arm CT (CACT) during selective transcatheter angiography with those of multidetector CT (MDCT) in the detection of hepatocellular carcinoma (HCC). In this prospective study, 30 patients (mean age, 73 years) with unresectable HCC were examined with CACT before chemoembolisation. Images of a combination of CACT during arterial portography (CACTAP) and dual-phase CACT during hepatic arteriography (CACTHA) was obtained and images of intravenous contrast-enhanced, biphasic, dynamic, MDCT was also obtained beforehand. Three blinded observers independently reviewed CACT and MDCT. Diagnostic accuracy was evaluated by the alternative free-response receiver operating characteristic (AFROC) method. Sensitivities and positive predictive values (PPV) were analyzed with the paired t-test. In the mean area under the AFROC curve (Az), there was no significant difference between MDCT and CACT (MDCT, mean Az value, 0.83; CACT, 0.85, respectively) (P = 0.32). There was also no significant difference between the two techniques in sensitivity (MDCT, mean 0.65; CACT, 0.60) and PPV (MDCT, mean 0.98; CACT, 0.97) (P = 0.40, P = 0.68, respectively). The diagnostic accuracy of CACT was equivalent to that of biphasic CT in the diagnosis of HCC. (orig.)

  12. The effect of positive end-expiratory pressure on pulse pressure ...

    African Journals Online (AJOL)

    The effect of positive end-expiratory pressure on pulse pressure variation. FJ Smith, M Geyser, I Schreuder, PJ Becker. Abstract. Objectives: To determine the effect of different levels of positive end-expiratory pressure (PEEP) on pulse pressure variation (PPV). Design: An observational study. Setting: Operating theatres of a ...

  13. Evaluation of portosystemic collaterals by MDCT-MPR imaging for management of hemorrhagic esophageal varices

    International Nuclear Information System (INIS)

    Kodama, Hideaki; Aikata, Hiroshi; Takaki, Shintaro; Azakami, Takahiro; Katamura, Yoshio; Kawaoka, Tomokazu; Hiramatsu, Akira; Waki, Koji; Imamura, Michio; Kawakami, Yoshiiku; Takahashi, Shoichi; Toyota, Naoyuki; Ito, Katsuhide; Chayama, Kazuaki

    2010-01-01

    Objective: To study the correlation between changes in portosystemic collaterals, evaluated by multidetector-row computed tomography imaging using multiplanar reconstruction (MDCT-MPR), and prognosis in patients with hemorrhagic esophageal varices (EV) after endoscopic treatment. Methods: Forty-nine patients with primary hemostasis for variceal bleeding received radical endoscopic treatment: endoscopic injection sclerotherapy (EIS) or endoscopic variceal ligation (EVL). Patients were classified according to the rate of reduction in feeding vessel diameter on MDCT-MPR images, into the narrowing (n = 24) and no-change (n = 25) groups. We evaluated changes in portosystemic collaterals by MDCT-MPR before and after treatment, and determined rebleeding and survival rates. Results: The left gastric and paraesophageal (PEV) veins were recognized as portosystemic collaterals in 100 and 80%, respectively, of patients with EV on MDCT-MPR images. The rebleeding rates at 1, 2, 3, and 5 years after endoscopic treatment were 10, 15, 23, and 23%, respectively, for the narrowing group, and 17, 24, 35, and 67%, respectively, for the no-change group (P = 0.068). Among no-change group, the rebleeding rate in patients with large PEV was significantly lower than that with small PEV (P = 0.027). The rebleeding rate in patients with small PEV of the no-change group was significantly higher than that in the narrowing group (P = 0.018). There was no significant difference in rebleeding rates between the no-change group with a large PEV and narrowing group (P = 0.435). Conclusion: Changes in portosystemic collaterals evaluated by MDCT-MPR imaging correlate with rebleeding rate. Evaluation of portosystemic collaterals in this manner would provide useful information for the management of hemorrhagic EV.

  14. Low radiation dose non-contrast cardiac CT: is it of value in the evaluation of mechanical aortic valve

    International Nuclear Information System (INIS)

    Bazeed, Mohamed Fayez; Moselhy, Mohamed Saleh; Rezk, Ahmad Ibrahim; Al-Murayeh, Mushabab Ayedh

    2012-01-01

    Background: Prosthetic bileaflet mechanical valve function has been traditionally evaluated using echocardiography and fluoroscopy. Multidetector computed tomography (MDCT) is a novel technique for cardiac evaluation. Purpose: To evaluate bileaflet mechanical aortic valves using a low-milliampere (mA), non-contrast MDCT protocol with a limited scan range. Material and Methods: Forty patients with a bileaflet mechanical aortic valve were evaluated using a non-contrast, low-mA, ECG-gated 64 MDCT protocol with a limited scan range. MDCT findings of opening and closing valve angles were correlated to fluoroscopy and echocardiography. Also, the valve visibility was evaluated on MDCT and fluoroscopy according to a 3-point grading scale. Results: The visualization score with the MDCT was significantly superior to the fluoroscopy (3 vs. 2.7). A strong correlation was noted between the opening (r = 0.82) and closing (r = 0.96) valve angles with MDCT and fluoroscopy without a statistically significant difference (P = 0.31 and 0.16, respectively). The mean effective radiation dose of the suggested protocol was 4 ± 0.5 mSv. Five valves were evaluated using transesophageal echocardiography because the valves were difficult to evaluate with transthoracic echocardiography, and all of these valves were evaluated optimally with MDCT. A high-pressure gradient was noted in nine valves, and the MDCT showed that seven of these valves inadequately opened, and two valves opened well, which resulted in patient valve mismatch. Incomplete valve closure was noted in five valves, and the echocardiography showed significant transvalvular regurgitation in all five valves. Conclusion: MDCT can provide a precise measurement of valve function and can potentially evaluate high-pressure gradients and transvalvular regurgitation

  15. Low radiation dose non-contrast cardiac CT: is it of value in the evaluation of mechanical aortic valve

    Energy Technology Data Exchange (ETDEWEB)

    Bazeed, Mohamed Fayez (Dept. of Diagnostic Radiology, Faculty of Medicine, Mansoura Univ. (Egypt)), email: m_bazeed@yahoo.com; Moselhy, Mohamed Saleh (Cardiology Dept. Faculty of Medicine, Suez Canal Univ. (Egypt)); Rezk, Ahmad Ibrahim (Dept. of Cardiac Surgery, Faculty of Medicine, Aim Shams Univ. (Egypt)); Al-Murayeh, Mushabab Ayedh (Dept. of Cardiac Services, Armed Forces Hospitals Southern Region (Saudi Arabia))

    2012-05-15

    Background: Prosthetic bileaflet mechanical valve function has been traditionally evaluated using echocardiography and fluoroscopy. Multidetector computed tomography (MDCT) is a novel technique for cardiac evaluation. Purpose: To evaluate bileaflet mechanical aortic valves using a low-milliampere (mA), non-contrast MDCT protocol with a limited scan range. Material and Methods: Forty patients with a bileaflet mechanical aortic valve were evaluated using a non-contrast, low-mA, ECG-gated 64 MDCT protocol with a limited scan range. MDCT findings of opening and closing valve angles were correlated to fluoroscopy and echocardiography. Also, the valve visibility was evaluated on MDCT and fluoroscopy according to a 3-point grading scale. Results: The visualization score with the MDCT was significantly superior to the fluoroscopy (3 vs. 2.7). A strong correlation was noted between the opening (r = 0.82) and closing (r = 0.96) valve angles with MDCT and fluoroscopy without a statistically significant difference (P = 0.31 and 0.16, respectively). The mean effective radiation dose of the suggested protocol was 4 +- 0.5 mSv. Five valves were evaluated using transesophageal echocardiography because the valves were difficult to evaluate with transthoracic echocardiography, and all of these valves were evaluated optimally with MDCT. A high-pressure gradient was noted in nine valves, and the MDCT showed that seven of these valves inadequately opened, and two valves opened well, which resulted in patient valve mismatch. Incomplete valve closure was noted in five valves, and the echocardiography showed significant transvalvular regurgitation in all five valves. Conclusion: MDCT can provide a precise measurement of valve function and can potentially evaluate high-pressure gradients and transvalvular regurgitation

  16. Incidental finding of both cholecystoduodenal fistula and caecum carcinoma with MDCT imaging

    International Nuclear Information System (INIS)

    Groudeva, V.; Adam, G.; Malla Houech, I-V.; Davidkov, L.; Stoinova, V.

    2015-01-01

    Full text: Bouveret’s syndrome is a rare condition of gastric outlet obstruction, due to the impaction of gallstones in the duodenum. Most commonly it affects women and usually a history of cholelithiasis is present. We present the case of 86 years old female, with complaints of fullness, belching, acids, loss of appetite and weight for a few weeks. The examination revealed soft abdomen, painful palpation and a palpable movable mass in the right lower quadrant. The patient was referred to the imaging department for assessment of the finding. MDCT of the abdomen was carried out on 320 - row Aquillion ONE Toshiba machine, using contrast medium. The aim is to clarifying the accurate managing of the diagnosis of cholecystoduodenal fistula using MDCT. MDCT identified the presence of two independent from one another diseases, characterized by similar complaints. An enhancing mass with irregular borders in the caecal area was visualized. In addition presence of pneumobilia and a communication extending from the gallbladder to the duodenum and calculi in the latter were identified.The findings were consistent with cholecystoduodenal fistula. the patient underwent surgery, right hemicolectomy was performed together with duodenotomy and calculus extraction. Different conditions may present with overlapping symptoms and imaging diagnostic comes in help with the investigation. Since the condition of cholecystoduodenal fistula is associated with high risk of complications and death, it appeals to quick diagnosis and treatment. the use of MDCT in clinical practice as a non-invasive method allows precise identification of the signs of this disease

  17. Inspiratory and expiratory HRCT findings in healthy smokers' lung

    International Nuclear Information System (INIS)

    Park, Hyeon Seon; Kwak, Byung Kook; Choi, Chi Hoon; Yang, Keun Mung; Lee, Chang Joon; Joo, Dong Il; Kim, Yang Soo

    1998-01-01

    The purpose of this study is to evaluate the lung changes in healthy smokers, as seen on inspiratory and expiratory high-resolution computed tomography (HRCT). Twenty-seven healthy smokers (light smokers, below 20 pack-years, n=16; heavy smokers, above 20 pack-years, n=11) and 25 nonsmokers underwent inspiratory and expiratory HRCT. All healthy smokers had normal pulmonary function and chest radiography. Parenchymal and subpleural micronodules, ground-glass attenuation, centrilobular and paraseptal emphysema, bronchial wall thickening, bronchiectasis and septal line were evaluated on inspiratory scan and by air-trapping on expiratory scan. According to the findings of HRCT, heavy smokers and higher frequency of parenchymal micronodules, ground-glass attenuation, centrilobular and paraseptal emphysema, and air-trapping than nonsmokers and light smokers. (author). 13 refs., 1 tab., 4 figs

  18. Renal sympathetic denervation: MDCT evaluation of the renal arteries.

    LENUS (Irish Health Repository)

    Hutchinson, Barry D

    2013-08-01

    Percutaneous transluminal renal sympathetic denervation is a new treatment of refractory systemic hypertension. The purpose of this study was to assess the clinical utility of MDCT to evaluate the anatomic configuration of the renal arteries in the context of renal sympathetic denervation.

  19. In the workup of patients with obscure gastrointestinal bleed, does 64-slice MDCT have a role?

    International Nuclear Information System (INIS)

    Kulkarni, Chinmay; Moorthy, Srikanth; Sreekumar, KP; Rajeshkannan, R; Nazar, PK; Sandya, CJ; Sivasubramanian, S; Ramchandran, PV

    2012-01-01

    The purpose was to prospectively determine the sensitivity of 64-slice MDCT in detecting and diagnosing the cause of obscure gastrointestinal bleed (OGIB). Our study included 50 patients (male 30, female 20) in the age range of 3–82 years (average age: 58.52 years) who were referred to our radiology department as part of their workup for clinically evident gastrointestinal (GI) bleed or as part of workup for anemia (with and without positive fecal occult blood test). All patients underwent conventional upper endoscopy and colonoscopy before undergoing CT scan. Following a noncontrast scan, all patients underwent triple-phase contrast CT scan using a 64-slice CT scan system. The diagnostic performance of 64-slice MDCT was compared to the results of capsule endoscopy, 99m-technetium-labeled red blood cell scintigraphy (99mTc-RBC scintigraphy), digital subtraction angiography, and surgery whenever available. CT scan showed positive findings in 32 of 50 patients. The sensitivity, specificity, positive predictive value, and negative predictive values of MDCT for detection of bleed were 72.2%, 42.8%, 81.2%, and 44.4%, respectively. Capsule endoscopy was done in 15 patients and was positive in 10 patients; it had a sensitivity of 71.4%. Eleven patients had undergone 99mTc-RBC scintigraphy prior to CT scan, and the result was positive in seven patients (sensitivity 70%). Digital subtraction angiography was performed in only eight patients and among them all except one patient showed findings consistent with the lesions detected on MDCT. MDCT is a sensitive and noninvasive tool that allows rapid detection and localization of OGIB. It can be used as the first-line investigation in patients with negative endoscopy and colonoscopy studies. MDCT and capsule endoscopy have complementary roles in the evaluation of OGIB

  20. Use of tidal breathing curves for evaluating expiratory airway obstruction in infants.

    Science.gov (United States)

    Hevroni, Avigdor; Goldman, Aliza; Blank-Brachfeld, Miriam; Abu Ahmad, Wiessam; Ben-Dov, Lior; Springer, Chaim

    2018-01-15

    To evaluate tidal breathing (TB) flow-volume and flow-time curves for identification of expiratory airway obstruction in infants. Pulmonary function tests were analyzed retrospectively in 156 infants aged 3-24 months with persistent or recurrent respiratory complaints. Parameters derived from TB curves were compared to maximal expiratory flow at functional residual capacity ([Formula: see text]maxFRC) measured by rapid thoracoabdominal compression technique. Analyzed parameters were: inspiratory time (t I ), expiratory time (t E ), tidal volume, peak tidal expiratory flow (PTEF), time to peak tidal expiratory flow (t PTEF ), expiratory flow when 50% and 25% of tidal volume remains in the lungs (FEF 50 , FEF 25 , respectively), and the ratios t PTEF /t E , t I /t E , FEF 50 /PTEF, and FEF 25 /PTEF. Statistical comparisons between flow indices and TB parameters were performed using mean squared error and Pearson's sample correlation coefficient. The study population was also divided into two groups based on severity of expiratory obstruction (above or below z-score for [Formula: see text]maxFRC of -2) to generate receiver operating characteristic (ROC) curves and calculate discriminatory values between the groups. TB parameters that were best correlated to [Formula: see text]maxFRC were: t PTEF /t E , FEF 50 /PTEF, and FEF 25 /PTEF, with r = 0.61, 0.67, 0.65, respectively (p < 0.0001 for all). ROC curves for FEF 50 /PTEF, FEF 25 /PTEF and t PTEF /t E showed areas under the curve of 0.813, 0.797, and 0.796, respectively. Cutoff value z-scores of -0.35, -0.34, and -0.43 for these three parameters, respectively, showed an 86% negative predictive value for severe airway obstructions. TB curves can assist in ruling out severe expiratory airway obstruction in infants.

  1. MDCT findings in sports and recreational accidents

    Energy Technology Data Exchange (ETDEWEB)

    Bensch, Frank V; Koivikko, Mika P; Koskinen, Seppo K (Dept. of Radiology, Toeoeloe Hospital, Helsinki (Finland)), email: frank.bensch@hus.fi

    2011-12-15

    Background. Sports and recreational accidents involving critical areas of the body occur commonly in the general population. Reports on their demographics and recommendations for screening procedures are, however, few. Purpose. To assess injuries of the craniofacial area, spine, and torso resulting from sports and recreational accidents with multidetector computed tomography (MDCT) as primary imaging method in a Level I trauma center. Material and Methods. All emergency room CT requests over a time span of 105 months were reviewed retrospectively for trauma mechanism and injury. Patients were identified using an electronic picture archiving and communications system (PACS), and MDCT studies interpreted by two radiologists independently. Results. Of a total of 5898 patients, 492 patients (301 boys/men, 191 girls/women, age range 2-76 years, mean 33.5 years, median 29.5 years) with sports or recreational accidents emerged. A total of 102 traumatic findings were diagnosed, thereof 72 (71%) serious. The three most commonly encountered serious injuries were intracranial injury, fractures of facial bones, and vertebral injuries. The three most common injury mechanisms were bicycling, horseback riding, and team ball sports. Patients from recreational activities were on average significantly younger (29.2 years) than those from sports accidents (36.9 years; P < 0.001). Only age groups <21 years and 41-50 years differed in injury severity from the other age groups (P = 0.004 and P = 0.063, respectively). Of all trauma mechanisms, only bicycling had a significantly increased risk of injury (P < 0.001). Conclusion. Injuries in sports and recreational accidents presented with an overall incidence of 21%, of which 71% are serious. The most common mechanisms of injury were bicycling, horseback riding, and team ball sports. The largest incidence of serious injury involved bicycling. Because of the high probability of a serious injury and the high energies that are often involved

  2. MDCT findings in sports and recreational accidents

    International Nuclear Information System (INIS)

    Bensch, Frank V; Koivikko, Mika P; Koskinen, Seppo K

    2011-01-01

    Background. Sports and recreational accidents involving critical areas of the body occur commonly in the general population. Reports on their demographics and recommendations for screening procedures are, however, few. Purpose. To assess injuries of the craniofacial area, spine, and torso resulting from sports and recreational accidents with multidetector computed tomography (MDCT) as primary imaging method in a Level I trauma center. Material and Methods. All emergency room CT requests over a time span of 105 months were reviewed retrospectively for trauma mechanism and injury. Patients were identified using an electronic picture archiving and communications system (PACS), and MDCT studies interpreted by two radiologists independently. Results. Of a total of 5898 patients, 492 patients (301 boys/men, 191 girls/women, age range 2-76 years, mean 33.5 years, median 29.5 years) with sports or recreational accidents emerged. A total of 102 traumatic findings were diagnosed, thereof 72 (71%) serious. The three most commonly encountered serious injuries were intracranial injury, fractures of facial bones, and vertebral injuries. The three most common injury mechanisms were bicycling, horseback riding, and team ball sports. Patients from recreational activities were on average significantly younger (29.2 years) than those from sports accidents (36.9 years; P < 0.001). Only age groups <21 years and 41-50 years differed in injury severity from the other age groups (P = 0.004 and P = 0.063, respectively). Of all trauma mechanisms, only bicycling had a significantly increased risk of injury (P < 0.001). Conclusion. Injuries in sports and recreational accidents presented with an overall incidence of 21%, of which 71% are serious. The most common mechanisms of injury were bicycling, horseback riding, and team ball sports. The largest incidence of serious injury involved bicycling. Because of the high probability of a serious injury and the high energies that are often involved

  3. MR-Imaging of teeth and periodontal apparatus: an experimental study comparing high-resolution MRI with MDCT and CBCT

    International Nuclear Information System (INIS)

    Gaudino, Chiara; Csernus, Reka; Pham, Mirko; Bendszus, Martin; Rohde, Stefan; Cosgarea, Raluca; Kim, Ti-Sun; Heiland, Sabine; Beomonte Zobel, Bruno

    2011-01-01

    The aim of this study was (1) to assess the ability of magnetic resonance imaging (MRI) to visualize dental and periodontal structures and (2) to compare findings with multidetector computed tomography (MDCT) and cone beam CT (CBCT). Four porcine mandibles were examined with (1) 3T-MRI, (2) MDCT and (3) CBCT. Two observers independently reviewed MR, MDCT and CBCT images and assessed image quality of different dental and periodontal structures. To assess quantitatively the accuracy of the different imaging technique, both observers measured burr holes, previously drilled in the mandibles. Dental structures, e.g. teeth roots, pulpa chamber and dentin, were imaged accurately with all imaging sources. Periodontal space and cortical/trabecular bone were better visualized by MRI (p < 0.001). MRI could excellently display the lamina dura, not detectable with MDCT and only inconstant visible with CBCT (p < 0.001). Burr hole measurements were highly precise with all imaging techniques. This experimental study shows the diagnostic feasibility of MRI in visualization of teeth and periodontal anatomy. Detection of periodontal structures was significantly better with MRI than with MDCT or CBCT. Prospective trials have to evaluate further the potential benefit of MRI in a clinical setting. (orig.)

  4. MR-Imaging of teeth and periodontal apparatus: an experimental study comparing high-resolution MRI with MDCT and CBCT

    Energy Technology Data Exchange (ETDEWEB)

    Gaudino, Chiara; Csernus, Reka; Pham, Mirko; Bendszus, Martin; Rohde, Stefan [University Hospital Heidelberg, Department of Neuroradiology, Heidelberg (Germany); Cosgarea, Raluca; Kim, Ti-Sun [University Hospital Heidelberg, Department of Periodontology, Heidelberg (Germany); Heiland, Sabine [University Hospital Heidelberg, Section of Experimental Radiology, Heidelberg (Germany); Beomonte Zobel, Bruno [University Campus Bio-Medico of Rome, Department of Radiology, Interdisciplinary Center for Biomedical Research, Rome (Italy)

    2011-12-15

    The aim of this study was (1) to assess the ability of magnetic resonance imaging (MRI) to visualize dental and periodontal structures and (2) to compare findings with multidetector computed tomography (MDCT) and cone beam CT (CBCT). Four porcine mandibles were examined with (1) 3T-MRI, (2) MDCT and (3) CBCT. Two observers independently reviewed MR, MDCT and CBCT images and assessed image quality of different dental and periodontal structures. To assess quantitatively the accuracy of the different imaging technique, both observers measured burr holes, previously drilled in the mandibles. Dental structures, e.g. teeth roots, pulpa chamber and dentin, were imaged accurately with all imaging sources. Periodontal space and cortical/trabecular bone were better visualized by MRI (p < 0.001). MRI could excellently display the lamina dura, not detectable with MDCT and only inconstant visible with CBCT (p < 0.001). Burr hole measurements were highly precise with all imaging techniques. This experimental study shows the diagnostic feasibility of MRI in visualization of teeth and periodontal anatomy. Detection of periodontal structures was significantly better with MRI than with MDCT or CBCT. Prospective trials have to evaluate further the potential benefit of MRI in a clinical setting. (orig.)

  5. The effects of emphysema on airway disease: Correlations between multi-detector CT and pulmonary function tests in smokers

    International Nuclear Information System (INIS)

    Yahaba, Misuzu; Kawata, Naoko; Iesato, Ken; Matsuura, Yukiko; Sugiura, Toshihiko; Kasai, Hajime; Sakurai, Yoriko; Terada, Jiro; Sakao, Seiichiro; Tada, Yuji; Tanabe, Nobuhiro; Tatsumi, Koichiro

    2014-01-01

    Background: Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation caused by emphysema and small airway narrowing. Quantitative evaluation of airway dimensions by multi-detector computed tomography (MDCT) has revealed a correlation between airway dimension and airflow limitation. However, the effect of emphysema on this correlation is unclear. Objective: The goal of this study was to determine whether emphysematous changes alter the relationships between airflow limitation and airway dimensions as measured by inspiratory and expiratory MDCT. Methods: Ninety-one subjects underwent inspiratory and expiratory MDCT. Images were evaluated for mean airway luminal area (Ai), wall area percentage (WA%) from the third to the fifth generation of three bronchi (B1, B5, B8) in the right lung, and low attenuation volume percent (LAV%). Correlations between each airway index and airflow limitation were determined for each patient and compared between patients with and without evidence of emphysema. Results: In patients without emphysema, Ai and WA% from both the inspiratory and expiratory scans were significantly correlated with FEV 1. No correlation was detected in patients with emphysema. In addition, emphysematous COPD patients with GOLD stage 1 or 2 disease had significantly lower changes in B8 Ai than non-emphysematous patients. Conclusions: A significant correlation exists between airway parameters and FEV 1 in patients without emphysema. Emphysema may influence airway dimensions even in patients with mild to moderate COPD

  6. The effects of emphysema on airway disease: Correlations between multi-detector CT and pulmonary function tests in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Yahaba, Misuzu, E-mail: mis_misuzu@yahoo.co.jp; Kawata, Naoko, E-mail: chumito_03@yahoo.co.jp; Iesato, Ken, E-mail: iesato_k@yahoo.co.jp; Matsuura, Yukiko, E-mail: matsuyuki_future@yahoo.co.jp; Sugiura, Toshihiko, E-mail: sugiura@js3.so-net.ne.jp; Kasai, Hajime, E-mail: daikasai6075@yahoo.co.jp; Sakurai, Yoriko, E-mail: yoliri@nifty.com; Terada, Jiro, E-mail: jirotera@chiba-u.jp; Sakao, Seiichiro, E-mail: sakao@faculty.chiba-u.jp; Tada, Yuji, E-mail: ytada@faculty.chiba-u.jp; Tanabe, Nobuhiro, E-mail: ntanabe@faculty.chiba-u.jp; Tatsumi, Koichiro, E-mail: tatsumi@faculty.chiba-u.jp

    2014-06-15

    Background: Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation caused by emphysema and small airway narrowing. Quantitative evaluation of airway dimensions by multi-detector computed tomography (MDCT) has revealed a correlation between airway dimension and airflow limitation. However, the effect of emphysema on this correlation is unclear. Objective: The goal of this study was to determine whether emphysematous changes alter the relationships between airflow limitation and airway dimensions as measured by inspiratory and expiratory MDCT. Methods: Ninety-one subjects underwent inspiratory and expiratory MDCT. Images were evaluated for mean airway luminal area (Ai), wall area percentage (WA%) from the third to the fifth generation of three bronchi (B1, B5, B8) in the right lung, and low attenuation volume percent (LAV%). Correlations between each airway index and airflow limitation were determined for each patient and compared between patients with and without evidence of emphysema. Results: In patients without emphysema, Ai and WA% from both the inspiratory and expiratory scans were significantly correlated with FEV{sub 1.} No correlation was detected in patients with emphysema. In addition, emphysematous COPD patients with GOLD stage 1 or 2 disease had significantly lower changes in B8 Ai than non-emphysematous patients. Conclusions: A significant correlation exists between airway parameters and FEV{sub 1} in patients without emphysema. Emphysema may influence airway dimensions even in patients with mild to moderate COPD.

  7. Interaction between intra-abdominal pressure and positive-end expiratory pressure

    Directory of Open Access Journals (Sweden)

    Jamili Anbar Torquato

    2009-02-01

    Full Text Available OBJECTIVE: The aim of this study was to quantify the interaction between increased intra-abdominal pressure and Positive-End Expiratory Pressure. METHODS: In 30 mechanically ventilated ICU patients with a fixed tidal volume, respiratory system plateau and abdominal pressure were measured at a Positive-End Expiratory Pressure level of zero and 10 cm H2O. The measurements were repeated after placing a 5 kg weight on the patients' belly. RESULTS: After the addition of 5 kg to the patients' belly at zero Positive-End Expiratory Pressure, both intra-abdominal pressure (p<0.001 and plateau pressures (p=0.005 increased significantly. Increasing the Positive-End Expiratory Pressure levels from zero to 10 cm H2O without weight on the belly did not result in any increase in intra-abdominal pressure (p=0.165. However, plateau pressures increased significantly (p< 0.001. Increasing Positive-End Expiratory Pressure from zero to 10 cm H2O and adding 5 kg to the belly increased intra-abdominal pressure from 8.7 to 16.8 (p<0.001 and plateau pressure from 18.26 to 27.2 (p<0.001. Maintaining Positive-End Expiratory Pressure at 10 cm H2O and placing 5 kg on the belly increased intra-abdominal pressure from 12.3 +/- 1.7 to 16.8 +/- 1.7 (p<0.001 but did not increase plateau pressure (26.6+/-1.2 to 27.2 +/-1.1 -p=0.83. CONCLUSIONS: The addition of a 5kg weight onto the abdomen significantly increased both IAP and the airway plateau pressure, confirming that intra-abdominal hypertension elevates the plateau pressure. However, plateau pressure alone cannot be considered a good indicator for the detection of elevated intra-abdominal pressure in patients under mechanical ventilation using PEEP. In these patients, the intra-abdominal pressure must also be measured.

  8. Polyarteritis nodosa: MDCT as a 'One-Stop Shop' Modality for Whole-Body Arterial Evaluation

    International Nuclear Information System (INIS)

    Tsai, W.-L.; Tsai, I-C.; Lee Tain; Hsieh, C.-W.

    2008-01-01

    Polyarteritis nodosa is a rare disease, which is characterized by aneurysm formation and occlusion in the arteries of multiple systems. Due to its extensive involvement, whole-body evaluation is necessary for diagnosis and treatment monitoring. We report a case of polyarteritis nodosa using multidetector-row computed tomography (MDCT) as a 'one-stop shop' modality for whole-body arterial evaluation. With precise protocol design, MDCT can be used as a reliable noninvasive modality providing comprehensive whole-body arterial evaluation.

  9. Dose titration to reduce dipyridamole-related headache.

    Science.gov (United States)

    Chang, Yeu-Jhy; Ryu, Shan-Jin; Lee, Tsong-Hai

    2006-01-01

    Combination of low-dose aspirin and modified-release dipyridamole (ASA+MR-DP) provides a significantly increased benefit in stroke prevention over aspirin alone. However, headaches were reported in more patients receiving dipyridamole-containing agents than in those receiving placebo. We undertook a randomized, double-blind, placebo-controlled trial to evaluate which dosing regimens of ASA+MR-DP have better tolerance. This trial randomized 146 patients with a history of ischemic cerebrovascular disease into three groups: placebo (days 1-28), reduced dose (placebo on days 1-4, ASA+MR-DP once daily before bed during days 5-14, and b.i.d. on days 15-28), and regular dose (placebo on days 1-4, and ASA+MR-DP b.i.d. on days 5-28). Using Chinese diary card, headache was assessed as mean cumulated headache (Sigma frequency x intensity/occurrence days x study days) over the study period, and was graded 0-4 according to Cancer Therapy Evaluation Program, Common Toxicity Criteria, Version 2.0. Intent-to-treat patients after randomization was 46 in placebo group, 45, reduced dose, and 49, regular dose. Among commonly reported adverse effects, headache of any grade occurred significantly more in the regular dose group (38.8%), as compared to the other two groups (p < 0.05). Mean cumulated headache was higher (p < 0.05) in the regular dose group than in the reduced group during days 5-14. Of 27 patients who dropped out, 15 (55.6%) were due to headache, which was substantially more in regular dose (8, 53.3%), though the difference was statistically insignificant. Initial reduced dose treatment with ASA+MR-DP may cause fewer headaches than regular dosing, and seems better tolerated by those susceptible to phosphodiesterase inhibitor-induced headache. Copyright 2006 S. Karger AG, Basel.

  10. Demonstration of vascular abnormalities compressing esophagus by MDCT: Special focus on dysphagia lusoria

    Energy Technology Data Exchange (ETDEWEB)

    Alper, Fatih [Department of Radiology, Medical Faculty, Atatuerk University, Erzurum (Turkey)]. E-mail: fatihrad@yahoo.com; Akgun, Metin [Department of Chest Diseases, Medical Faculty, Atatuerk University, Erzurum (Turkey); Kantarci, Mecit [Department of Radiology, Medical Faculty, Atatuerk University, Erzurum (Turkey); Eroglu, Atilla [Department of Thoracic Surgery, Medical Faculty, Atatuerk University, Erzurum (Turkey); Ceyhan, Elvan [Department of Mathematics, College of Arts and Sciences, Koc University, Istanbul (Turkey); Onbas, Omer [Department of Radiology, Medical Faculty, Atatuerk University, Erzurum (Turkey); Duran, Cihan [Department of Radiology, Florence Nightingale Hospital, Istanbul (Turkey); Okur, Adnan [Department of Radiology, Medical Faculty, Atatuerk University, Erzurum (Turkey)

    2006-07-15

    Purpose: Dysphagia lusoria (DL) is described in the literature as difficulty in swallowing caused by vascular abnormalities. The most common cause is an aberrant right subclavian artery (SCA) which passes behind the esophagus and is also called arteria lusoria (AL). Our aim was to demonstrate the use of multidetector computed tomography (MDCT) in the diagnosis of AL, as there is no comprehensive study investigating the role of MDCT in such cases. Material and methods: A total of 38 consecutive patients, comprising of 23 females (61%) and 15 males (39%), who had extrinsic compression were included in the study. These patients are selected from the cases who were admitted due to their gastrointestinal symptoms, such as dysphagia, epigastric pain, chronic nausea, vomiting, etc. The mean age of patients was 40 {+-} 25 years (range 15-65). Following barium esophagogram and then endoscopy performed, MDCT angiography was carried out on the same or the following few days. MDCT sections were examined to determine the following: presence of vascular abnormality; the diameter and angle of that vascular structure; and the compressed area of esophagus. Radiological findings and dysphagia scores were also compared. Results: In each of 15 cases, there was a compression due to vascular abnormality which were all located between the esophagus and the spine. There was an esophageal compression in each of 12 cases, due to right aberrant SCA, in one case due to right superior aortic arch and in two cases due to both right aortic arch and left SCA with Kommerell's diverticulum. The mean diameter and the angle of AL were 16.4 mm and 48.8{sup o}, respectively, and the mean area of pressured esophagus was 194.7 mm{sup 2}. Dysphagia scores of the cases was 1 in thirteen cases and 2 in two cases. However, dysphagia scores were not correlated with these parameters. Conclusions: MDCT angiography is a useful diagnostic tool for evaluation of patients with dysphagia, especially caused by a

  11. Demonstration of vascular abnormalities compressing esophagus by MDCT: Special focus on dysphagia lusoria

    International Nuclear Information System (INIS)

    Alper, Fatih; Akgun, Metin; Kantarci, Mecit; Eroglu, Atilla; Ceyhan, Elvan; Onbas, Omer; Duran, Cihan; Okur, Adnan

    2006-01-01

    Purpose: Dysphagia lusoria (DL) is described in the literature as difficulty in swallowing caused by vascular abnormalities. The most common cause is an aberrant right subclavian artery (SCA) which passes behind the esophagus and is also called arteria lusoria (AL). Our aim was to demonstrate the use of multidetector computed tomography (MDCT) in the diagnosis of AL, as there is no comprehensive study investigating the role of MDCT in such cases. Material and methods: A total of 38 consecutive patients, comprising of 23 females (61%) and 15 males (39%), who had extrinsic compression were included in the study. These patients are selected from the cases who were admitted due to their gastrointestinal symptoms, such as dysphagia, epigastric pain, chronic nausea, vomiting, etc. The mean age of patients was 40 ± 25 years (range 15-65). Following barium esophagogram and then endoscopy performed, MDCT angiography was carried out on the same or the following few days. MDCT sections were examined to determine the following: presence of vascular abnormality; the diameter and angle of that vascular structure; and the compressed area of esophagus. Radiological findings and dysphagia scores were also compared. Results: In each of 15 cases, there was a compression due to vascular abnormality which were all located between the esophagus and the spine. There was an esophageal compression in each of 12 cases, due to right aberrant SCA, in one case due to right superior aortic arch and in two cases due to both right aortic arch and left SCA with Kommerell's diverticulum. The mean diameter and the angle of AL were 16.4 mm and 48.8 o , respectively, and the mean area of pressured esophagus was 194.7 mm 2 . Dysphagia scores of the cases was 1 in thirteen cases and 2 in two cases. However, dysphagia scores were not correlated with these parameters. Conclusions: MDCT angiography is a useful diagnostic tool for evaluation of patients with dysphagia, especially caused by a vascular

  12. Usefulness of multidetector computed tomography (MDCT) for the initial evaluation of multiple blunt trauma of the trunk

    International Nuclear Information System (INIS)

    Hagiwara, Shuichi; Ogino, Takashi; Isaka, Akira; Takahashi, Yuga; Nameki, Tarou; Kagoshima, Kaie; Yamada, Takurou; Ishihara, Kouichi; Iino, Yuichi

    2008-01-01

    Focused assessment with sonography for trauma (FAST) is useful for detecting hemoperitoneum (HE) in trauma patients in the emergency room (ER), but, patients' condition cannot be evaluated adequately by FAST alone. CT is useful for the diagnosis of multiple trauma, but has certain drawbacks. We evaluated the utility of multidetector computed tomography (MDCT) as the initial tool for proper diagnosis and treatment planning of multiple trauma patients. We retrospectively analyzed 128 cases treated in ER of Gunma University Hospital between April 1, 2005 and December 31, 2006, and they were hospital patients were hospitalized with blunt multiple trauma. We analyzed the sensitivity, specificity, and accuracy of FAST, compiled MDCT finding, lifesaving treatment, and outcome. Eight patients were FAST positive, and 7 of the 8 were scanned by MDCT. There were 120 patients were FAST negative patients, 23 of the 120 were MDCT-negative, despite visceral injury, however 9 of the 120 had visceral injury by MDCT findings. Damage control surgery without MDCT was performed in one case, but the patient died after surgery. Six of the patients in the HE-positive group had really HE. One of the 6 died while a waiting surgery, transcatheter arterial embolization (TAE) was performed in three patients, and one person out of the 3 died. The course of the remaining 2 patients was monitored, and they are alive. A patient in the HE-negative group with bladder rupture required surgery. There were 120 patients in the FAST-negative group. One of the 6 patients in the HE-positive subgroup died while a waiting surgery. One patient required chest and pericardial drainage. TAE was performed in 2 patients, and the remaining 6 were monitored and are alive. There were 23 FAST-negative patients patients who had visceral injury. Five of them required chest drainage, one received TAE, 17 were monitored, and all of the 23 are alive. There were 14 cases of pelvic fracture alone, and all of them were FAST

  13. Functional Magnetic Stimulation of Inspiratory and Expiratory Muscles in Subjects With Tetraplegia.

    Science.gov (United States)

    Zhang, Xiaoming; Plow, Ela; Ranganthan, Vinoth; Huang, Honglian; Schmitt, Melissa; Nemunaitis, Gregory; Kelly, Clay; Frost, Frederick; Lin, Vernon

    2016-07-01

    Respiratory complications are major causes of morbidity and mortality in persons with a spinal cord injury, partly because of respiratory muscle paralysis. Earlier investigation has demonstrated that functional magnetic stimulation (FMS) can be used as a noninvasive technology for activating expiratory muscles, thus producing useful expiratory functions (simulated cough) in subjects with spinal cord injury. To evaluate the effectiveness of FMS for conditioning inspiratory and expiratory muscles in persons with tetraplegia. A prospective before and after trial. FMS Laboratory, Louis Stokes Cleveland VA Medical Center, Cleveland, OH. Six persons with tetraplegia. Each subject participated in a 6-week FMS protocol for conditioning the inspiratory and expiratory muscles. A magnetic stimulator was used with the center of a magnetic coil placed at the C7-T1 and T9-T10 spinous processes, respectively. Pulmonary function tests were performed before, during, and after the protocol. Respiratory variables included maximal inspiratory pressure (MIP), inspiratory reserve volume (IRV), peak inspiratory flow (PIF), maximal expiratory pressure (MEP), expiratory reserve volume (ERV), and peak expiratory flow (PEF). After 6 weeks of conditioning, the main outcome measurements (mean ± standard error) were as follows: MIP, 89.6 ± 7.3 cm H2O; IRV, 1.90 ± 0.34 L; PIF, 302.4 ± 36.3 L/min; MEP, 67.4 ± 11.1 cm H2O; ERV, 0.40 ± 0.06 L; and PEF, 372.4 ± 31.9 L/min. These values corresponded to 117%, 107%, 136%, 109%, 130%, and 124% of pre-FMS conditioning values, respectively. Significant improvements were observed in MIP (P = .022), PIF (P = .0001), and PEF (P = .0006), respectively. When FMS was discontinued for 4 weeks, these values showed decreases from their values at the end of the conditioning protocol, which suggests that continual FMS may be necessary to maintain improved respiratory functions. FMS conditioning of the inspiratory and expiratory muscles improved

  14. Dose estimation in CT exams of the abdomen based on values of DLP; Estimativa da dose em exames de tomografia de abdome com base nos valores de DLP

    Energy Technology Data Exchange (ETDEWEB)

    Kikuti, C.F.; Medeiros, R.B.; Salvadori, P.S.; Costa, D.M.C; D' lppolito, G., E-mail: kikuticf@gmail.com, E-mail: rbitelli2011@gmail.com [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Coordenadoria de Fisica e Higiene das Radiacoes. Departamento de Diagnostico por Imagem

    2013-10-01

    One of the challenges of multidetector computerized tomography is to minimize the risk of ionizing radiation using optimized protocols since higher doses are necessary to obtain high image quality. It was also noted that, due to the geometry in image acquisition using MDCT becomes necessary to estimate dose values consistent with the hypothesis clinically and with the specificities of the tomographic equipment. The aim of this study was to estimate the doses in abdomen exams from the data recorded on the MDCT console and dimensions obtained from DICOM images of patients undergoing different clinical protocols. Were collected, from the image DICOM of 101 exams, values of the dose length product (DLP) provided by Philips Health Care - Brilliance 64 equipment console, in order to relate them with the dose values obtained by means of thermoluminescent dosimeters ( TLD ) of CasSo{sub 4}:Mn placed on the surface of a cylindrical simulator abdomen acrylic manufactured under the technical - operational conditions for a typical abdomen exam. From the data obtained, it was possible to find a factor of 1.16 ( 5 % ) indicating that the DLP values Brilliance 64 console underestimate the doses and this should be used with correction factor to estimate the total dose of the patient. (author)

  15. FCT (functional computed tomography) evaluation of the lung volumes at different PEEP (positive-end expiratory pressure) ventilation pattern, in mechanical ventilated patients

    International Nuclear Information System (INIS)

    Papi, M.G.; Di Segni, R.; Mazzetti, G.; Staffa, F.; Conforto, F.; Calimici, R.; Salvi, A.; Matteucci, G.

    2007-01-01

    Purpose To evaluate with FCT (functional computed tomography) total lung volume and fractional lung volumes at different PEEP (positive end expiratory pressure) values in acute mechanically ventilated patients. Methods Nine ICU (intensive care unity) patients (1 lung pneumonia, 2 polytrauma, 2 sepsis, 3 brain surgery, 1 pulmonary embolism); mean age 48 ± 15 years, 6 male, 3 female; GE 16 MDCT scan was performed with acquisition from apex to diaphragma in seven seca at different PEEP values. Raw CT data were analysed by an advantage workstation to obtain volume density masks and histograms of both lungs and each lung and these density ranges were applied: - 1000 - 950 hyper-ventilated lung, -900 - 650 well aerated lung, -950 - 500 all aerated lung, -500 + 200 lung tissue. Total and fractional lung volumes, Hounsfield unit (HU) were calculated and compared at different PEEP values (0, 5, 10, 15 cm H 2 O). In four patients lung volumes were compared between the more and the less involved lung at increased PEEP. Statistic analysis: comparison means-medians tests. Results Data calculated at five PEEP showed unexpected decrease of total lung volume and increase of lung density (HU); proportionally no significant improvement of oxigenation. (orig.)

  16. FCT (functional computed tomography) evaluation of the lung volumes at different PEEP (positive-end expiratory pressure) ventilation pattern, in mechanical ventilated patients

    Energy Technology Data Exchange (ETDEWEB)

    Papi, M.G.; Di Segni, R.; Mazzetti, G.; Staffa, F. [Dept. of Radiology, S. Giovanni HS, Rome (Italy); Conforto, F.; Calimici, R.; Salvi, A. [Dept. of Anesthesiology, S. Giovanni HS, Rome (Italy); Matteucci, G. [Dept. of Pneumology, S. Giovanni HS, Rome (Italy)

    2007-06-15

    Purpose To evaluate with FCT (functional computed tomography) total lung volume and fractional lung volumes at different PEEP (positive end expiratory pressure) values in acute mechanically ventilated patients. Methods Nine ICU (intensive care unity) patients (1 lung pneumonia, 2 polytrauma, 2 sepsis, 3 brain surgery, 1 pulmonary embolism); mean age 48 {+-} 15 years, 6 male, 3 female; GE 16 MDCT scan was performed with acquisition from apex to diaphragma in seven seca at different PEEP values. Raw CT data were analysed by an advantage workstation to obtain volume density masks and histograms of both lungs and each lung and these density ranges were applied: - 1000 - 950 = hyper-ventilated lung, -900 - 650 well aerated lung, -950 - 500 all aerated lung, -500 + 200 lung tissue. Total and fractional lung volumes, Hounsfield unit (HU) were calculated and compared at different PEEP values (0, 5, 10, 15 cm H{sub 2}O). In four patients lung volumes were compared between the more and the less involved lung at increased PEEP. Statistic analysis: comparison means-medians tests. Results Data calculated at five PEEP showed unexpected decrease of total lung volume and increase of lung density (HU); proportionally no significant improvement of oxigenation. (orig.)

  17. Noninvasive evaluation of active lower gastrointestinal bleeding: comparison between contrast-enhanced MDCT and 99mTc-labeled RBC scintigraphy.

    Science.gov (United States)

    Zink, Stephen I; Ohki, Stephen K; Stein, Barry; Zambuto, Domenic A; Rosenberg, Ronald J; Choi, Jenny J; Tubbs, Daniel S

    2008-10-01

    The purpose of our study was to compare contrast-enhanced MDCT and (99m)Tc-labeled RBC scanning for the evaluation of active lower gastrointestinal bleeding. Over 17 months, 55 patients (32 men, 23 women; age range, 21-92 years) were evaluated prospectively with contrast-enhanced MDCT using 100 mL of iopromide 300 mg I/mL. Technetium-99m-labeled RBC scans were obtained on 41 of 55 patients and select patients underwent angiography for attempted embolization. Each imaging technique was reviewed in a blinded fashion for sensitivity for detection of active bleeding as well as the active lower gastrointestinal bleeding location. Findings were positive on both examinations in eight patients and negative on both examinations in 20 patients. Findings were positive on contrast-enhanced MDCT and negative on (99m)Tc-labeled RBC in two patients; findings were negative on contrast-enhanced MDCT and positive on (99m)Tc-labeled RBC in 11 patients. Statistics showed significant disagreement, with simple agreement = 68.3%, kappa = 0.341, and p = 0.014. Sixteen of 60 (26.7%) contrast-enhanced MDCT scans were positive prospectively, with all accurately localizing the site of bleeding and identification of the underlying lesion in eight of 16 (50%). Nineteen of 41 (46.3%) (99m)Tc-labeled RBC scans were positive. Eighteen of 41 matched patients went on to angiography. In four of these 18 (22.2%) patients, the site of bleeding was confirmed by angiography, but in 14 of 18 (77.8%), the findings were negative. Contrast-enhanced MDCT and (99m)Tc-labeled RBC scanning show significant disagreement for evaluation of active lower gastrointestinal bleeding. Contrast-enhanced MDCT appears effective for detection and localization in cases of active lower gastrointestinal bleeding in which hemorrhage is active at the time of CT.

  18. Comprehensive cardiovascular ECG-gated MDCT as a standard diagnostic tool in patients with acute chest pain

    Energy Technology Data Exchange (ETDEWEB)

    Runza, G. [Department of Radiology, University of Palermo (Italy)], E-mail: grunza@sirm.org; La Grutta, L.; Alaimo, V. [Department of Radiology, University of Palermo (Italy); Evola, S. [Department of Cardiology, University of Palermo (Italy); Lo Re, F.; Bartolotta, T.V. [Department of Radiology, University of Palermo (Italy); Cademartiri, F. [Department of Radiology and Cardiology, Erasmus Medical Center, Rotterdam (Netherlands); Department of Radiology and Cardiology, Cardiovascular CT Unit, University Hospital, Parma (Italy); Midiri, M. [Department of Radiology, University of Palermo (Italy)

    2007-10-15

    Acute myocardial infarction, pulmonary embolism, and aortic dissection are diseases associated with acute chest pain and may lead to severe morbidity and mortality. These diseases may not be trivial to diagnose in the settings of emergency room. ECG-gated multi-detector computed tomography (MDCT), already established for the assessment of pulmonary embolism and aortic dissection, provides reliable information regarding the triage of patients with acute coronary syndrome in the emergency room. MDCT recently appeared to be logistically feasible and a promising comprehensive method for the evaluation of cardiac and non-cardiac chest pain in emergency department patients. The possibility to scan the entire thorax visualizing the thoracic aorta, the pulmonary arteries, and the coronary arteries could provide a new approach to the triage of acute chest pain. The inherent advantage of MDCT with cardiac state-of-the-art capabilities is the rapid investigation of the main sources of acute chest pain with a high negative predictive value. Recent studies also reports an advantage in terms of costs. With current evidence, the selection of patients with acute chest pain candidates to MDCT should remain restricted to avoid unjustified risk of ionizing radiation.

  19. Comprehensive cardiovascular ECG-gated MDCT as a standard diagnostic tool in patients with acute chest pain

    International Nuclear Information System (INIS)

    Runza, G.; La Grutta, L.; Alaimo, V.; Evola, S.; Lo Re, F.; Bartolotta, T.V.; Cademartiri, F.; Midiri, M.

    2007-01-01

    Acute myocardial infarction, pulmonary embolism, and aortic dissection are diseases associated with acute chest pain and may lead to severe morbidity and mortality. These diseases may not be trivial to diagnose in the settings of emergency room. ECG-gated multi-detector computed tomography (MDCT), already established for the assessment of pulmonary embolism and aortic dissection, provides reliable information regarding the triage of patients with acute coronary syndrome in the emergency room. MDCT recently appeared to be logistically feasible and a promising comprehensive method for the evaluation of cardiac and non-cardiac chest pain in emergency department patients. The possibility to scan the entire thorax visualizing the thoracic aorta, the pulmonary arteries, and the coronary arteries could provide a new approach to the triage of acute chest pain. The inherent advantage of MDCT with cardiac state-of-the-art capabilities is the rapid investigation of the main sources of acute chest pain with a high negative predictive value. Recent studies also reports an advantage in terms of costs. With current evidence, the selection of patients with acute chest pain candidates to MDCT should remain restricted to avoid unjustified risk of ionizing radiation

  20. Effects of positive end-expiratory pressure and recruitment maneuvers in a ventilator-induced injury mouse model.

    Directory of Open Access Journals (Sweden)

    Laura A Cagle

    Full Text Available Positive-pressure mechanical ventilation is an essential therapeutic intervention, yet it causes the clinical syndrome known as ventilator-induced lung injury. Various lung protective mechanical ventilation strategies have attempted to reduce or prevent ventilator-induced lung injury but few modalities have proven effective. A model that isolates the contribution of mechanical ventilation on the development of acute lung injury is needed to better understand biologic mechanisms that lead to ventilator-induced lung injury.To evaluate the effects of positive end-expiratory pressure and recruitment maneuvers in reducing lung injury in a ventilator-induced lung injury murine model in short- and longer-term ventilation.5-12 week-old female BALB/c mice (n = 85 were anesthetized, placed on mechanical ventilation for either 2 hrs or 4 hrs with either low tidal volume (8 ml/kg or high tidal volume (15 ml/kg with or without positive end-expiratory pressure and recruitment maneuvers.Alteration of the alveolar-capillary barrier was noted at 2 hrs of high tidal volume ventilation. Standardized histology scores, influx of bronchoalveolar lavage albumin, proinflammatory cytokines, and absolute neutrophils were significantly higher in the high-tidal volume ventilation group at 4 hours of ventilation. Application of positive end-expiratory pressure resulted in significantly decreased standardized histology scores and bronchoalveolar absolute neutrophil counts at low- and high-tidal volume ventilation, respectively. Recruitment maneuvers were essential to maintain pulmonary compliance at both 2 and 4 hrs of ventilation.Signs of ventilator-induced lung injury are evident soon after high tidal volume ventilation (as early as 2 hours and lung injury worsens with longer-term ventilation (4 hrs. Application of positive end-expiratory pressure and recruitment maneuvers are protective against worsening VILI across all time points. Dynamic compliance can be used guide

  1. Effects of positive end-expiratory pressure and recruitment maneuvers in a ventilator-induced injury mouse model

    Science.gov (United States)

    Franzi, Lisa M.; Linderholm, Angela L.; Last, Jerold A.; Adams, Jason Y.; Harper, Richart W.

    2017-01-01

    Background Positive-pressure mechanical ventilation is an essential therapeutic intervention, yet it causes the clinical syndrome known as ventilator-induced lung injury. Various lung protective mechanical ventilation strategies have attempted to reduce or prevent ventilator-induced lung injury but few modalities have proven effective. A model that isolates the contribution of mechanical ventilation on the development of acute lung injury is needed to better understand biologic mechanisms that lead to ventilator-induced lung injury. Objectives To evaluate the effects of positive end-expiratory pressure and recruitment maneuvers in reducing lung injury in a ventilator-induced lung injury murine model in short- and longer-term ventilation. Methods 5–12 week-old female BALB/c mice (n = 85) were anesthetized, placed on mechanical ventilation for either 2 hrs or 4 hrs with either low tidal volume (8 ml/kg) or high tidal volume (15 ml/kg) with or without positive end-expiratory pressure and recruitment maneuvers. Results Alteration of the alveolar-capillary barrier was noted at 2 hrs of high tidal volume ventilation. Standardized histology scores, influx of bronchoalveolar lavage albumin, proinflammatory cytokines, and absolute neutrophils were significantly higher in the high-tidal volume ventilation group at 4 hours of ventilation. Application of positive end-expiratory pressure resulted in significantly decreased standardized histology scores and bronchoalveolar absolute neutrophil counts at low- and high-tidal volume ventilation, respectively. Recruitment maneuvers were essential to maintain pulmonary compliance at both 2 and 4 hrs of ventilation. Conclusions Signs of ventilator-induced lung injury are evident soon after high tidal volume ventilation (as early as 2 hours) and lung injury worsens with longer-term ventilation (4 hrs). Application of positive end-expiratory pressure and recruitment maneuvers are protective against worsening VILI across all time points

  2. Effects of positive end-expiratory pressure and recruitment maneuvers in a ventilator-induced injury mouse model.

    Science.gov (United States)

    Cagle, Laura A; Franzi, Lisa M; Linderholm, Angela L; Last, Jerold A; Adams, Jason Y; Harper, Richart W; Kenyon, Nicholas J

    2017-01-01

    Positive-pressure mechanical ventilation is an essential therapeutic intervention, yet it causes the clinical syndrome known as ventilator-induced lung injury. Various lung protective mechanical ventilation strategies have attempted to reduce or prevent ventilator-induced lung injury but few modalities have proven effective. A model that isolates the contribution of mechanical ventilation on the development of acute lung injury is needed to better understand biologic mechanisms that lead to ventilator-induced lung injury. To evaluate the effects of positive end-expiratory pressure and recruitment maneuvers in reducing lung injury in a ventilator-induced lung injury murine model in short- and longer-term ventilation. 5-12 week-old female BALB/c mice (n = 85) were anesthetized, placed on mechanical ventilation for either 2 hrs or 4 hrs with either low tidal volume (8 ml/kg) or high tidal volume (15 ml/kg) with or without positive end-expiratory pressure and recruitment maneuvers. Alteration of the alveolar-capillary barrier was noted at 2 hrs of high tidal volume ventilation. Standardized histology scores, influx of bronchoalveolar lavage albumin, proinflammatory cytokines, and absolute neutrophils were significantly higher in the high-tidal volume ventilation group at 4 hours of ventilation. Application of positive end-expiratory pressure resulted in significantly decreased standardized histology scores and bronchoalveolar absolute neutrophil counts at low- and high-tidal volume ventilation, respectively. Recruitment maneuvers were essential to maintain pulmonary compliance at both 2 and 4 hrs of ventilation. Signs of ventilator-induced lung injury are evident soon after high tidal volume ventilation (as early as 2 hours) and lung injury worsens with longer-term ventilation (4 hrs). Application of positive end-expiratory pressure and recruitment maneuvers are protective against worsening VILI across all time points. Dynamic compliance can be used guide the frequency

  3. Adult exposures from MDCT including multiphase studies: first Italian nationwide survey

    Energy Technology Data Exchange (ETDEWEB)

    Palorini, Federica; Origgi, Daniela [Fisica Sanitaria Istituto Europeo di Oncologia, Milan (Italy); Granata, Claudio [UOC di Radiologia Istituto Giannina Gaslini, Genoa (Italy); Matranga, Domenica [Universita degli Studi di Palermo, Dipartimento di Scienze per la Promozione della Salute e Materno-infantile ' ' G. D' Alessandro' ' , Palermo (Italy); Salerno, Sergio [Policlinico Universita di Palermo, Dipartimento di Scienze Radiologiche, Palermo (Italy)

    2014-02-15

    To evaluate the radiation dose in routine multidetector computed tomography (MDCT) examinations in Italian population. This was a retrospective multicentre study included 5,668 patients from 65 radiology departments who had undergone common CT protocols: head, chest, abdomen, chest-abdomen-pelvis (CAP), spine and cardiac. Data included patient characteristics, CT parameters, volumetric CT dose index (CTDI{sub vol}) and dose length product (DLP) for each CT acquisition phase. Descriptive statistics were calculated, and a multi-regression analysis was used to outline the main factors affecting exposure. The 75th percentiles of CTDI{sub vol} (mGy) and DLP (mGy cm) for whole head were 69 mGy and 1,312 mGy cm, respectively; for chest, 15 mGy and 569 mGy cm; spine, 42 mGy and 888 mGy cm; cardiac, 7 mGy and 131 mGy cm for calcium score, and 61 mGy and 1,208 mGy cm for angiographic CT studies. High variability was present in the DLP of abdomen and CAP protocols, where multiphase examinations dominated (71 % and 73 % respectively): for abdomen, 18 mGy, with 555 and 920 mGy cm in abdomen and abdomen-pelvis acquisitions respectively; for CAP, 17 mGy, with 508, 850 and 1,200 mGy cm in abdomen, abdomen-pelvis and CAP acquisitions respectively. The results of this survey could help in the definition of updated diagnostic reference levels (DRL). (orig.)

  4. A systematic approach towards the objective evaluation of low-contrast performance in MDCT: Combination of a full-reference image fidelity metric and a software phantom

    International Nuclear Information System (INIS)

    Falck, Christian von; Rodt, Thomas; Waldeck, Stephan; Hartung, Dagmar; Meyer, Bernhard; Wacker, Frank; Shin, Hoen-oh

    2012-01-01

    Objectives: To assess the feasibility of an objective approach for the evaluation of low-contrast detectability in multidetector computed-tomography (MDCT) by combining a virtual phantom containing simulated lesions with an image quality metric. Materials and methods: A low-contrast phantom containing hypodense spheric lesions (−20 HU) was scanned on a 64-slice MDCT scanner at 4 different dose levels (25, 50, 100, 200 mAs). In addition, virtual round hypodense low-contrast lesions (20 HU object contrast) based on real CT data were inserted into the lesion-free section of the datasets. The sliding-thin-slab algorithm was applied to the image data with an increasing slice-thickness from 1 to 15 slices. For each dataset containing simulated lesions a lesion-free counterpart was reconstructed and post-processed in the same manner. The low-contrast performance of all datasets containing virtual lesions was determined using a full-reference image quality metric (modified multiscale structural similarity index, MS-SSIM*). The results were validated against a reader-study of the real lesions. Results: For all dose levels and lesion sizes there was no statistically significant difference between the low-contrast performance as determined by the image quality metric when compared to the reader study (p < 0.05). The intraclass correlation coefficient was 0.72, 0.82, 0.90 and 0.84 for lesion diameters of 4 mm, 5 mm, 8 mm and 10 mm, respectively. The use of the sliding-thin-slab algorithm improves lesion detectability by a factor ranging from 1.15 to 2.69 when compared with the original axial slice (0.625 mm). Conclusion: The combination of a virtual phantom and a full-reference image quality metric enables a systematic, automated and objective evaluation of low-contrast detectability in MDCT datasets and correlates well with the judgment of human readers.

  5. Feasibility of opportunistic osteoporosis screening in routine contrast-enhanced multi detector computed tomography (MDCT) using texture analysis.

    Science.gov (United States)

    Mookiah, M R K; Rohrmeier, A; Dieckmeyer, M; Mei, K; Kopp, F K; Noel, P B; Kirschke, J S; Baum, T; Subburaj, K

    2018-04-01

    This study investigated the feasibility of opportunistic osteoporosis screening in routine contrast-enhanced MDCT exams using texture analysis. The results showed an acceptable reproducibility of texture features, and these features could discriminate healthy/osteoporotic fracture cohort with an accuracy of 83%. This aim of this study is to investigate the feasibility of opportunistic osteoporosis screening in routine contrast-enhanced MDCT exams using texture analysis. We performed texture analysis at the spine in routine MDCT exams and investigated the effect of intravenous contrast medium (IVCM) (n = 7), slice thickness (n = 7), the long-term reproducibility (n = 9), and the ability to differentiate healthy/osteoporotic fracture cohort (n = 9 age and gender matched pairs). Eight texture features were extracted using gray level co-occurrence matrix (GLCM). The independent sample t test was used to rank the features of healthy/fracture cohort and classification was performed using support vector machine (SVM). The results revealed significant correlations between texture parameters derived from MDCT scans with and without IVCM (r up to 0.91) slice thickness of 1 mm versus 2 and 3 mm (r up to 0.96) and scan-rescan (r up to 0.59). The performance of the SVM classifier was evaluated using 10-fold cross-validation and revealed an average classification accuracy of 83%. Opportunistic osteoporosis screening at the spine using specific texture parameters (energy, entropy, and homogeneity) and SVM can be performed in routine contrast-enhanced MDCT exams.

  6. Detection of occult vertebral fractures by quantitative assessment of bone marrow attenuation values at MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Henes, Frank Oliver, E-mail: f.henes@uke.de [Department of Diagnostic and Interventional Radiology, Center for Radiology and Endoscopy, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Groth, Michael [Department of Diagnostic and Interventional Neuroradiology, Center for Radiology and Endoscopy, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Kramer, Harald [Department of Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Marchioninistr. 15, 81377 Munich (Germany); Department of Radiology, University of Wisconsin – Madison, Clinical Science Center, 600 Highland Avenue, Madison, WI 53792 (United States); Schaefer, Christian [Department of Trauma-, Hand- and Reconstructive Surgery, Spine Center, Center for Surgical Sciences, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg (Germany); Regier, Marc; Derlin, Thorsten; Adam, Gerhard; Bannas, Peter [Department of Diagnostic and Interventional Radiology, Center for Radiology and Endoscopy, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany)

    2014-01-15

    Objectives: To determine a cut-off value of Hounsfield attenuation units (HU) at multidetector computed tomography (MDCT) for valid and reliable detection of bone marrow oedema (BME) related to occult vertebral fractures. Methods: 36 patients underwent both MDCT and Magnetic Resonance Imaging (MRI) for evaluation of vertebral fractures of the thoracolumbar spine and were included in this retrospective study. Two readers independently assessed HU values at MDCT in a total of 196 vertebrae. Reliability was assessed by intraclass correlation coefficient and Bland–Altman analysis. For each patient we determined the vertebra with the lowest HU value and calculated the HU-difference to each other vertebral body. HU-differences were subjected to receiver operating characteristic (ROC) curve analysis to determine the diagnostic accuracy for detection of BME as determined by MRI, which served as the reference standard. Results of HU-measurements were compared with standard visual evaluation of MDCT. Results: HU measurements demonstrated a high interrater reliability (ICC = 0.984). ROC curve analysis (AUC = 0.978) exhibited an ideal cut-off value of 29.6 HU for detection of BME associated with vertebral fractures with an accuracy of 97.4% as compared to 93.4% accuracy of visual evaluation. Particularly, HU-measurements increased the sensitivity for detection of vertebral fractures from 78.0% to 92.7% due to the detection of 7 of 9 occult fractures that were missed by visual evaluation alone. Conclusions: Assessing bone marrow density by HU measurements using the cut-off of 29.6 HU is a valid and reliable tool for detection of BME related to occult vertebral fractures in MDCT. The introduced technique may allow more accurate treatment decisions and may make further diagnostic work-up with MRI unnecessary.

  7. Detection of occult vertebral fractures by quantitative assessment of bone marrow attenuation values at MDCT

    International Nuclear Information System (INIS)

    Henes, Frank Oliver; Groth, Michael; Kramer, Harald; Schaefer, Christian; Regier, Marc; Derlin, Thorsten; Adam, Gerhard; Bannas, Peter

    2014-01-01

    Objectives: To determine a cut-off value of Hounsfield attenuation units (HU) at multidetector computed tomography (MDCT) for valid and reliable detection of bone marrow oedema (BME) related to occult vertebral fractures. Methods: 36 patients underwent both MDCT and Magnetic Resonance Imaging (MRI) for evaluation of vertebral fractures of the thoracolumbar spine and were included in this retrospective study. Two readers independently assessed HU values at MDCT in a total of 196 vertebrae. Reliability was assessed by intraclass correlation coefficient and Bland–Altman analysis. For each patient we determined the vertebra with the lowest HU value and calculated the HU-difference to each other vertebral body. HU-differences were subjected to receiver operating characteristic (ROC) curve analysis to determine the diagnostic accuracy for detection of BME as determined by MRI, which served as the reference standard. Results of HU-measurements were compared with standard visual evaluation of MDCT. Results: HU measurements demonstrated a high interrater reliability (ICC = 0.984). ROC curve analysis (AUC = 0.978) exhibited an ideal cut-off value of 29.6 HU for detection of BME associated with vertebral fractures with an accuracy of 97.4% as compared to 93.4% accuracy of visual evaluation. Particularly, HU-measurements increased the sensitivity for detection of vertebral fractures from 78.0% to 92.7% due to the detection of 7 of 9 occult fractures that were missed by visual evaluation alone. Conclusions: Assessing bone marrow density by HU measurements using the cut-off of 29.6 HU is a valid and reliable tool for detection of BME related to occult vertebral fractures in MDCT. The introduced technique may allow more accurate treatment decisions and may make further diagnostic work-up with MRI unnecessary

  8. Dose estimation in CT exams of the abdomen based on values of DLP

    International Nuclear Information System (INIS)

    Kikuti, C.F.; Medeiros, R.B.; Salvadori, P.S.; Costa, D.M.C; D'lppolito, G.

    2013-01-01

    One of the challenges of multidetector computerized tomography is to minimize the risk of ionizing radiation using optimized protocols since higher doses are necessary to obtain high image quality. It was also noted that, due to the geometry in image acquisition using MDCT becomes necessary to estimate dose values consistent with the hypothesis clinically and with the specificities of the tomographic equipment. The aim of this study was to estimate the doses in abdomen exams from the data recorded on the MDCT console and dimensions obtained from DICOM images of patients undergoing different clinical protocols. Were collected, from the image DICOM of 101 exams, values of the dose length product (DLP) provided by Philips Health Care - Brilliance 64 equipment console, in order to relate them with the dose values obtained by means of thermoluminescent dosimeters ( TLD ) of CasSo 4 :Mn placed on the surface of a cylindrical simulator abdomen acrylic manufactured under the technical - operational conditions for a typical abdomen exam. From the data obtained, it was possible to find a factor of 1.16 ( 5 % ) indicating that the DLP values Brilliance 64 console underestimate the doses and this should be used with correction factor to estimate the total dose of the patient. (author)

  9. An intelligent framework for medical image retrieval using MDCT and multi SVM.

    Science.gov (United States)

    Balan, J A Alex Rajju; Rajan, S Edward

    2014-01-01

    Volumes of medical images are rapidly generated in medical field and to manage them effectively has become a great challenge. This paper studies the development of innovative medical image retrieval based on texture features and accuracy. The objective of the paper is to analyze the image retrieval based on diagnosis of healthcare management systems. This paper traces the development of innovative medical image retrieval to estimate both the image texture features and accuracy. The texture features of medical images are extracted using MDCT and multi SVM. Both the theoretical approach and the simulation results revealed interesting observations and they were corroborated using MDCT coefficients and SVM methodology. All attempts to extract the data about the image in response to the query has been computed successfully and perfect image retrieval performance has been obtained. Experimental results on a database of 100 trademark medical images show that an integrated texture feature representation results in 98% of the images being retrieved using MDCT and multi SVM. Thus we have studied a multiclassification technique based on SVM which is prior suitable for medical images. The results show the retrieval accuracy of 98%, 99% for different sets of medical images with respect to the class of image.

  10. Detection of biliary and vascular anatomy in living liver donors: Value of gadobenate dimeglumine enhanced MR and MDCT angiography

    International Nuclear Information System (INIS)

    Artioli, Diana; Tagliabue, Marianna; Aseni, Paolo; Sironi, Sandro; Vanzulli, Angelo

    2010-01-01

    Objective: To evaluate the performance of magnetic resonance (MR) and multidetector computed tomography (MDCT) in the assessment of living donor's vascular and biliary anatomy, having surgical findings as reference standard. Methods: Thirty-two living liver donors underwent MR cholangiography (1.5-T; standard cholangiography pulse sequences and delayed acquisitions after administration of biliary contrast agent) for biliary anatomy evaluation. MDCT (16-row multidetector scanner, multiphase protocol, 3 mm slice thickness) was also performed in all cases for the assessment of vascular anatomy before transplantation. Hepatic veins (<4 mm in diameter) were not considered. MR and MDCT images interpretation was performed by two reviewers by consensus, based on source axial images, multiplanar reformats, and three-dimensional (3D) postprocessing images. Surgical intraoperative findings were used as standard of reference. Results: At surgery, 17 biliary anomalies, 3 portal anomalies, 32 venous and 8 arterial variants were found in the 32 patients. MR correctly identified 15/17 biliary anomalies, with a sensitivity of 88% and a specificity of 93%. MDCT correctly identified 8/8 arterial, 3/3 portal and 29/32 venous variants, with a sensitivity of 100% and 91%, respectively, and a specificity of 100%. Conclusions: MR and MDCT proved to be efficient in evaluating living liver donor's biliary and vascular anatomy.

  11. Detection of biliary and vascular anatomy in living liver donors: Value of gadobenate dimeglumine enhanced MR and MDCT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Artioli, Diana, E-mail: diansadiana@gmail.com [Ospedale Niguarda Ca' Granda, Piazza Ospedale Maggiore 3, 20162 Milano (Italy); Tagliabue, Marianna; Aseni, Paolo; Sironi, Sandro; Vanzulli, Angelo [Ospedale Niguarda Ca' Granda, Piazza Ospedale Maggiore 3, 20162 Milano (Italy)

    2010-11-15

    Objective: To evaluate the performance of magnetic resonance (MR) and multidetector computed tomography (MDCT) in the assessment of living donor's vascular and biliary anatomy, having surgical findings as reference standard. Methods: Thirty-two living liver donors underwent MR cholangiography (1.5-T; standard cholangiography pulse sequences and delayed acquisitions after administration of biliary contrast agent) for biliary anatomy evaluation. MDCT (16-row multidetector scanner, multiphase protocol, 3 mm slice thickness) was also performed in all cases for the assessment of vascular anatomy before transplantation. Hepatic veins (<4 mm in diameter) were not considered. MR and MDCT images interpretation was performed by two reviewers by consensus, based on source axial images, multiplanar reformats, and three-dimensional (3D) postprocessing images. Surgical intraoperative findings were used as standard of reference. Results: At surgery, 17 biliary anomalies, 3 portal anomalies, 32 venous and 8 arterial variants were found in the 32 patients. MR correctly identified 15/17 biliary anomalies, with a sensitivity of 88% and a specificity of 93%. MDCT correctly identified 8/8 arterial, 3/3 portal and 29/32 venous variants, with a sensitivity of 100% and 91%, respectively, and a specificity of 100%. Conclusions: MR and MDCT proved to be efficient in evaluating living liver donor's biliary and vascular anatomy.

  12. Our experience with the acceptance and dosimetric validation of Somatom Force dual head MDCT in the Royal Hospital, Oman

    International Nuclear Information System (INIS)

    Al-Harthi, Ruqaia; Al-Kalbani, Munira; Arun Kumar, L.S.; Al-Shanfari, Jamal

    2017-01-01

    Computed Tomography (CT) has revolutionized diagnostic imaging since its discovery in early 70's. In Oman; 70,353 CT examinations were carried out in the year 2015. The increase in CT examinations will eventually result in the increase of population dose and the consequent risk of cancer in adults and particularly in children. Here, we discuss and share our experience with the acceptance and dosimetric validation of second Dual Head Somatom Force MDCT installed in the Royal Hospital, Oman using Ministry of Health's radiation acceptance and quality assurance protocol, before handing over for routine patient care work

  13. Pediatric CT dose reduction for suspected appendicitis: a practice quality improvement project using artificial Gaussian noise--part 1, computer simulations.

    Science.gov (United States)

    Callahan, Michael J; Kleinman, Patricia L; Strauss, Keith J; Bandos, Andriy; Taylor, George A; Tsai, Andy; Kleinman, Paul K

    2015-01-01

    The purpose of this study was to develop a departmental practice quality improvement project to systematically reduce CT doses for the evaluation of suspected pediatric appendicitis by introducing computer-generated gaussian noise. Two hundred MDCT abdominopelvic examinations of patients younger than 20 years performed with girth-based scanning parameters for suspected appendicitis were reviewed. Two judges selected 45 examinations in which the diagnosis of appendicitis was excluded (14, appendix not visualized; 31, normal appendix visualized). Gaussian noise was introduced into axial image series, creating five additional series acquired at 25-76% of the original dose. Two readers reviewed 270 image series for appendix visualization (4-point Likert scale and arrow localization). Volume CT dose index (CTDIvol) and size-specific dose estimate (SSDE) were calculated by use of patient girth. Confidence ratings and localization accuracy were analyzed with mixed models and nonparametric bootstrap analysis at a 0.05 significance level. The mean baseline SSDE for the 45 patients was 16 mGy (95% CI, 12-20 mGy), and the corresponding CTDIvol was 10 mGy (95% CI, 4-16 mGy). Changes in correct appendix localization frequencies were minor. There was no substantial trend with decreasing simulated dose level (p = 0.46). Confidence ratings decreased with increasing dose reduction (p = 0.007). The average decreases were -0.27 for the 25% simulated dose (p = 0.01), -0.17 for 33% (p = 0.03), and -0.03 for 43% (p = 0.65). Pediatric abdominal MDCT can be performed with 43% of the original dose (SSDE, 7 mGy; CTDIvol, 4.3 mGy) without substantially affecting visualization of a normal appendix.

  14. Hepatosplenic volumetric assessment at MDCT for staging liver fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Pickhardt, Perry J.; Malecki, Kyle; Hunt, Oliver F.; Beaumont, Claire; Kloke, John; Ziemlewicz, Timothy J.; Lubner, Meghan G. [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States)

    2017-07-15

    To investigate hepatosplenic volumetry at MDCT for non-invasive prediction of hepatic fibrosis. Hepatosplenic volume analysis in 624 patients (mean age, 48.8 years; 311 M/313 F) at MDCT was performed using dedicated software and compared against pathological fibrosis stage (F0 = 374; F1 = 48; F2 = 40; F3 = 65; F4 = 97). The liver segmental volume ratio (LSVR) was defined by Couinaud segments I-III over segments IV-VIII. All pre-cirrhotic fibrosis stages (METAVIR F1-F3) were based on liver biopsy within 1 year of MDCT. LSVR and total splenic volumes increased with stage of fibrosis, with mean(±SD) values of: F0: 0.26 ± 0.06 and 215.1 ± 88.5 mm{sup 3}; F1: 0.25 ± 0.08 and 294.8 ± 153.4 mm{sup 3}; F2: 0.331 ± 0.12 and 291.6 ± 197.1 mm{sup 3}; F3: 0.39 ± 0.15 and 509.6 ± 402.6 mm{sup 3}; F4: 0.56 ± 0.30 and 790.7 ± 450.3 mm{sup 3}, respectively. Total hepatic volumes showed poor discrimination (F0: 1674 ± 320 mm{sup 3}; F4: 1631 ± 691 mm{sup 3}). For discriminating advanced fibrosis (≥F3), the ROC AUC values for LSVR, total liver volume, splenic volume and LSVR/spleen combined were 0.863, 0.506, 0.890 and 0.947, respectively. Relative changes in segmental liver volumes and total splenic volume allow for non-invasive staging of hepatic fibrosis, whereas total liver volume is a poor predictor. Unlike liver biopsy or elastography, these CT volumetric biomarkers can be obtained retrospectively on routine scans obtained for other indications. (orig.)

  15. Utility of Postmortem Autopsy via Whole-Body Imaging: Initial Observations Comparing MDCT and 3.0T MRI Findings with Autopsy Findings

    International Nuclear Information System (INIS)

    Cha, Jang Gyu; Kim, Dong Hun; Paik, Sang Hyun

    2010-01-01

    We prospectively compared whole-body multidetector computed tomography (MDCT) and 3.0T magnetic resonance (MR) images with autopsy findings. Five cadavers were subjected to whole-body, 16- channel MDCT and 3.0T MR imaging within two hours before an autopsy. A radiologist classified the MDCT and 3.0T MRI findings into major and minor findings, which were compared with autopsy findings. Most of the imaging findings, pertaining to head and neck, heart and vascular, chest, abdomen, spine, and musculoskeletal lesions, corresponded to autopsy findings. The causes of death that were determined on the bases of MDCT and 3.0T MRI findings were consistent with the autopsy findings in four of five cases. CT was useful in diagnosing fatal hemorrhage and pneumothorax, as well as determining the shapes and characteristics of the fractures and the direction of external force. MRI was effective in evaluating and tracing the route of a metallic object, soft tissue lesions, chronicity of hemorrhage, and bone bruises. A postmortem MDCT combined with MRI is a potentially powerful tool, providing noninvasive and objective measurements for forensic investigations

  16. COMBINED REDUCED FORCED EXPIRATORY VOLUME IN 1-SECOND (FEV1) AND PERIPHERAL ARTERY DISEASE IN SEDENTARY ELDERS WITH FUNCTIONAL LIMITATIONS

    Science.gov (United States)

    Vaz Fragoso, Carlos A.; Hsu, Fang-Chi; Brinkley, Tina; Church, Timothy; Liu, Christine K.; Manini, Todd; Newman, Anne B.; Stafford, Randall S.; McDermott, Mary M.; Gill, Thomas M.

    2014-01-01

    Objectives Because they are potentially modifiable and may coexist, we evaluated the combined occurrence of a reduced forced expiratory volume in 1-second (FEV1) and peripheral artery disease (PAD), including its association with exertional symptoms, physical inactivity, and impaired mobility, in sedentary elders with functional limitations. Design Cross-sectional. Setting Lifestyle Interventions and Independence in Elder (LIFE) Study. Participants 1307 sedentary community-dwelling persons, mean age 78.9, with functional limitations (Short Physical Performance Battery [SPPB] the San Diego Claudication Questionnaire. Physical inactivity was evaluated by percent of accelerometry wear-time with activity the 400MWT (gait-speed The two combined conditions were associated with exertional dyspnea (adjusted odds ratio [adjOR] 2.59 [1.20, 5.60]) and slow gait-speed (adjOR 3.15 [1.72, 5.75]) but not with exertional leg symptoms, high sedentary-time, and moderate-to-severe mobility impairment. Conclusions In sedentary community-dwelling elders with functional limitations, a reduced FEV1 and PAD frequently coexisted and, in combination, were strongly associated with exertional dyspnea and slow gait-speed (a frailty indicator that increases the risk of deleterious outcomes). PMID:24973990

  17. Parameters affecting the tidal volume during expiratory abdominal compression in patients with prolonged tracheostomy mechanical ventilation.

    Science.gov (United States)

    Morino, Akira; Shida, Masahiro; Tanaka, Masashi; Sato, Kimihiro; Seko, Toshiaki; Ito, Shunsuke; Ogawa, Shunichi; Takahashi, Naoaki

    2015-07-01

    [Purpose] The aim of this study was to clarify physical parameters affecting the tidal volume during expiratory abdominal compression in patients with prolonged tracheostomy mechanical ventilation. [Methods] Eighteen patients with prolonged mechanical ventilation were included in this study. Expiratory abdominal compression was performed on patients lying in a supine position. The abdomen above the navel was vertically compressed in synchronization with expiration and released with inspiration. We measured the tidal volume during expiratory abdominal compression. [Results] The mean tidal volume during expiratory abdominal compression was higher than that at rest (430.6 ± 127.1 mL vs. 344.0 ± 94.3 mL). The tidal volume during expiratory abdominal compression was correlated with weight, days of ventilator support, dynamic compliance and abdominal expansion. Stepwise multiple regression analysis revealed that weight (β = 0.499), dynamic compliance (β = 0.387), and abdominal expansion (β = 0.365) were factors contributing to the tidal volume during expiratory abdominal compression. [Conclusion] Expiratory abdominal compression increased the tidal volume in patients with prolonged tracheostomy mechanical ventilation. The tidal volume during expiratory abdominal compression was influenced by each of the pulmonary conditions and the physical characteristics.

  18. Assessment of effective dose from cone beam CT imaging in SPECT/CT examination in comparison with other modalities

    International Nuclear Information System (INIS)

    Tonkopi, Elena; Ross, Andrew A.

    2016-01-01

    The aim of this study was to assess radiation dose from the cone beam computed tomography (CBCT) component of single photon emission tomography/computed tomography (SPECT/CT) examinations and to compare it with the radiopharmaceutical related dose as well as dose from multidetector computed tomography (MDCT). Effective dose (ED) from computed tomography (CT) was estimated using dose-length product values and anatomy-specific conversion factors. The contribution from the SPECT component was evaluated using ED per unit administered activity for the radiopharmaceuticals listed in the International Commission on Radiological Protection Publications 80 and 106. With the exception of cardiac studies (0.11 mSv), the CBCT dose (3.96-6.04 mSv) was similar to that from the radiopharmaceutical accounting for 29-56 % of the total ED from the examination. In comparison with MDCT examinations, the CBCT dose was 48 and 42 % lower for abdomen/pelvis and chest/abdomen/pelvis scans, respectively, while in the chest the CBCT scan resulted in higher dose (23 %). Radiation dose from the CT component should be taken into consideration when evaluating total SPECT/CT patient dose. (authors)

  19. Prevalence of 'high-riding' superior pericardial recesses on thin-section 16-MDCT scans

    Energy Technology Data Exchange (ETDEWEB)

    Basile, Antonio [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy)]. E-mail: antodoc@yahoo.com; Bisceglie, Paola [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy); Giulietti, Giorgio [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy); Calcara, Giacomo [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy); Figuera, Michele [Department of Radiology, Ospedale Vittorio Emanuele, Via Plebiscito 628, 95124 Catania (Italy); Mundo, Elena [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy); Granata, Antonio [Department of Nephrology, Ospedale Vittorio Emanuele, Via Plebiscito 628, 95124 Catania (Italy); Runza, Giuseppe [Department of Radiology, Policlinico Universitario, Via del Vespro 129, 90127 Palermo (Italy); Privitera, Carmelo [Department of Radiology, Ospedale Vittorio Emanuele, Via Plebiscito 628, 95124 Catania (Italy); Privitera, Giambattista [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy); Patti, Maria Teresa [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy)

    2006-08-15

    Objective: The aim of this study was to evaluate the prevalence of 'high-riding' superior pericardial recess (HRSPR) on thin-section (1 mm) 16-multidetector computed tomography (MDCT) scans. Materials and methods: Three hundred and fourteen consecutive chest CT scans obtained with a thin-section 16 MDCT were retrospectively evaluated. The prevalence and characteristic of HRSPR were analyzed. Results: HRSPR was depicted in 21 patients (11 men and 10 women) (6.6%) who ranged in age from 28 to 72 years (mean age, 57 years). The extended recesses were rounded/oval shaped in five patients and triangular, spindle, half moon or irregular shaped in the other 16 patients. Conclusion: Our data suggest as HRSPRs are more frequently and better depicted on thinsection MDCT scans, and this improves the capability to distinguish this superior extension of the superior aortic recess from abnormal findings such as lymphadenopathy, cystic lesions, and aortic dissection.

  20. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT - A pooled analysis of two randomized trials

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Henrik S. [University of Copenhagen, Department of Diagnostic Radiology, Copenhagen University Hospital Herlev, and Department of Diagnostic Sciences, Faculty of Health Sciences, Herlev (Denmark); Morcos, Sameh K. [University of Sheffield, Department of Diagnostic Imaging, Northern General Hospital, Sheffield (United Kingdom)

    2009-04-15

    The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients with glomerular filtration rate (GFR) <60 ml/min undergoing contrast-enhanced MDCT examinations and to compare the rates of CIN following the IV administration of low-osmolar contrast media (LOCM, iopamidol and iomeprol) and an iso-osmolar contrast medium (IOCM, iodixanol). A total of 301 adult patients with moderate-to-severe renal failure received a similar IV contrast dose (40 gI). Serum creatinine (SCr) was measured at screening, baseline and 48-72 {+-} 6 h after the MDCT examination. Primary CIN outcome was an increase in SCr {>=}0.5 mg/dl ({>=}44.2 {mu}mol/l) from baseline. The CIN rates were 2.3% in the total population, 0.6% when GFR >40 ml/min, 4.6% when GFR <40 ml/min and 7.8% in patients with GFR <30 ml/min. The incidence of CIN was significantly higher after iodixanol than after LOCM (seven patients, 4.7% following IOCM, no CIN cases following the LOCM; p = 0.007). Significant differences in favor of the LOCM were also observed in patients with GFR <40 ml/min and GFR <30 ml/min. Following the IV administration of nonionic contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM iopamidol and iomeprol, especially in high-risk patients. Differences in osmolality between these LOCM and iodixanol do not play a role in the genesis of CIN. (orig.)

  1. Comparison of hepatic MDCT, MRI, and DSA to explant pathology for the detection and treatment planning of hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    Lauren M. Ladd

    2016-12-01

    Full Text Available Background/Aims The diagnosis and treatment plan for hepatocellular carcinoma (HCC can be made from radiologic imaging. However, lesion detection may vary depending on the imaging modality. This study aims to evaluate the sensitivities of hepatic multidetector computed tomography (MDCT, magnetic resonance imaging (MRI, and digital subtraction angiography (DSA in the detection of HCC and the consequent management impact on potential liver transplant patients. Methods One hundred and sixteen HCC lesions were analyzed in 41 patients who received an orthotopic liver transplant (OLT. All of the patients underwent pretransplantation hepatic DSA, MDCT, and/or MRI. The imaging results were independently reviewed retrospectively in a blinded fashion by two interventional and two abdominal radiologists. The liver explant pathology was used as the gold standard for assessing each imaging modality. Results The sensitivity for overall HCC detection was higher for cross-sectional imaging using MRI (51.5%, 95% confidence interval [CI]=36.2-58.4% and MDCT (49.8%, 95% CI=43.7-55.9% than for DSA (41.7%, 95% CI=36.2-47.3% (P=0.05. The difference in false-positive rate was not statistically significant between MRI (22%, MDCT (29%, and DSA (29% (P=0.67. The sensitivity was significantly higher for detecting right lobe lesions than left lobe lesions for all modalities (MRI: 56.1% vs. 43.1%, MDCT: 55.0% vs. 42.0%, and DSA: 46.9% vs. 33.9%; all P<0.01. The sensitivities of the three imaging modalities were also higher for lesions ≥2 cm vs. <2 cm (MRI: 73.4% vs. 32.7%, MDCT: 66.9% vs. 33.8%, and DSA: 62.2% vs. 24.1%; all P<0.01. The interobserver correlation was rated as very good to excellent. Conclusion The sensitivity for detecting HCC is higher for MRI and MDCT than for DSA, and so cross-sectional imaging modalities should be used to evaluate OLT candidacy.

  2. The value of MDCT in diagnosis of splenic artery aneurysms

    International Nuclear Information System (INIS)

    Sun Cong; Liu Cheng; Wang Ximing; Wang Daoping

    2008-01-01

    Objective: To evaluate the clinical value of multiple detector computed tomography (MDCT) in the diagnosis and planning the treatment of splenic aneurysms. Methods: Eight cases with splenic artery aneurysms (SAA) were retrospectively reviewed. Sixty four-slice spiral CT scans were performed. Intravenous contrast material was injected at 4 ml/s, and arterial and venous phase images were obtained. Subsequently, arterial phase images were analyzed and made for CT angiography. The diagnosis was made by using axial and reconstructive images. All of the patients were also performed Doppler color echocardiography. Results: All patients showed splenic artery and splenic artery aneurysms clearly with CT arterial phase images. Among them, six patients had splenic artery aneurysms, one had giant splenic artery aneurysms (GSAA) and one had splenic artery pseudoaneurysms. Ultrasound examination only diagnosed six of them. Conclusion: MDCT is a noninvasive and valuable method in diagnosis of splenic artery aneurysms and has high value in determination of treatment plan

  3. The value of MDCT in diagnosis of splenic artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Sun Cong [Shandong University, Shandong Provincial Medical Imaging Institute, Road jing-wu No. 324, Jinan, Shandong 250021 (China)], E-mail: suncong03@163.com; Liu Cheng; Wang Ximing; Wang Daoping [Shandong University, Shandong Provincial Medical Imaging Institute, Road jing-wu No. 324, Jinan, Shandong 250021 (China)

    2008-03-15

    Objective: To evaluate the clinical value of multiple detector computed tomography (MDCT) in the diagnosis and planning the treatment of splenic aneurysms. Methods: Eight cases with splenic artery aneurysms (SAA) were retrospectively reviewed. Sixty four-slice spiral CT scans were performed. Intravenous contrast material was injected at 4 ml/s, and arterial and venous phase images were obtained. Subsequently, arterial phase images were analyzed and made for CT angiography. The diagnosis was made by using axial and reconstructive images. All of the patients were also performed Doppler color echocardiography. Results: All patients showed splenic artery and splenic artery aneurysms clearly with CT arterial phase images. Among them, six patients had splenic artery aneurysms, one had giant splenic artery aneurysms (GSAA) and one had splenic artery pseudoaneurysms. Ultrasound examination only diagnosed six of them. Conclusion: MDCT is a noninvasive and valuable method in diagnosis of splenic artery aneurysms and has high value in determination of treatment plan.

  4. Impact of expiratory strength training in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Plowman, Emily K; Watts, Stephanie A; Tabor, Lauren; Robison, Raele; Gaziano, Joy; Domer, Amanda S; Richter, Joel; Vu, Tuan; Gooch, Clifton

    2016-06-01

    We evaluated the feasibility and impact of expiratory muscle strength training (EMST) on respiratory and bulbar function in persons with amyotrophic lateral sclerosis (ALS). Twenty-five ALS patients participated in this delayed intervention open-label clinical trial. Following a lead-in period, patients completed a 5-week EMST protocol. Outcome measures included: maximum expiratory pressure (MEP); physiologic measures of swallow and cough; and penetration-aspiration scale (PAS) scores. Of participants who entered the active phase of the study (n = 15), EMST was well tolerated and led to significant increases in MEPs and maximum hyoid displacement during swallowing post-EMST (P < 0.05). No significant differences were observed for PAS scores or cough spirometry measures. EMST was feasible and well tolerated in this small cohort of ALS patients and led to improvements in expiratory force-generating pressures and swallow kinematics. Further investigation is warranted to confirm these preliminary findings. Muscle Nerve 54: 48-53, 2016. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  5. Iterative reconstruction reduces abdominal CT dose

    International Nuclear Information System (INIS)

    Martinsen, Anne Catrine Trægde; Sæther, Hilde Kjernlie; Hol, Per Kristian; Olsen, Dag Rune; Skaane, Per

    2012-01-01

    Objective: In medical imaging, lowering radiation dose from computed tomography scanning, without reducing diagnostic performance is a desired achievement. Iterative image reconstruction may be one tool to achieve dose reduction. This study reports the diagnostic performance using a blending of 50% statistical iterative reconstruction (ASIR) and filtered back projection reconstruction (FBP) compared to standard FBP image reconstruction at different dose levels for liver phantom examinations. Methods: An anthropomorphic liver phantom was scanned at 250, 185, 155, 140, 120 and 100 mA s, on a 64-slice GE Lightspeed VCT scanner. All scans were reconstructed with ASIR and FBP. Four readers evaluated independently on a 5-point scale 21 images, each containing 32 test sectors. In total 672 areas were assessed. ROC analysis was used to evaluate the differences. Results: There was a difference in AUC between the 250 mA s FBP images and the 120 and 100 mA s FBP images. ASIR reconstruction gave a significantly higher diagnostic performance compared to standard reconstruction at 100 mA s. Conclusion: A blending of 50–90% ASIR and FBP may improve image quality of low dose CT examinations of the liver, and thus give a potential for reducing radiation dose.

  6. Physiologic Evaluation of Ventilation Perfusion Mismatch and Respiratory Mechanics at Different Positive End-expiratory Pressure in Patients Undergoing Protective One-lung Ventilation.

    Science.gov (United States)

    Spadaro, Savino; Grasso, Salvatore; Karbing, Dan Stieper; Fogagnolo, Alberto; Contoli, Marco; Bollini, Giacomo; Ragazzi, Riccardo; Cinnella, Gilda; Verri, Marco; Cavallesco, Narciso Giorgio; Rees, Stephen Edward; Volta, Carlo Alberto

    2018-03-01

    Arterial oxygenation is often impaired during one-lung ventilation, due to both pulmonary shunt and atelectasis. The use of low tidal volume (VT) (5 ml/kg predicted body weight) in the context of a lung-protective approach exacerbates atelectasis. This study sought to determine the combined physiologic effects of positive end-expiratory pressure and low VT during one-lung ventilation. Data from 41 patients studied during general anesthesia for thoracic surgery were collected and analyzed. Shunt fraction, high V/Q and respiratory mechanics were measured at positive end-expiratory pressure 0 cm H2O during bilateral lung ventilation and one-lung ventilation and, subsequently, during one-lung ventilation at 5 or 10 cm H2O of positive end-expiratory pressure. Shunt fraction and high V/Q were measured using variation of inspired oxygen fraction and measurement of respiratory gas concentration and arterial blood gas. The level of positive end-expiratory pressure was applied in random order and maintained for 15 min before measurements. During one-lung ventilation, increasing positive end-expiratory pressure from 0 cm H2O to 5 cm H2O and 10 cm H2O resulted in a shunt fraction decrease of 5% (0 to 11) and 11% (5 to 16), respectively (P ventilation, high positive end-expiratory pressure levels improve pulmonary function without increasing high V/Q and reduce driving pressure.

  7. Work management practices that reduce dose and improve efficiency

    International Nuclear Information System (INIS)

    Miller, D.W.; Hulin, M.

    1998-01-01

    Work management practices at nuclear power plants can dramatically affect the outcome of annual site dose goals and outage costs. This presentation discusses global work management practices that contribute to dose reduction including work philosophy, work selection, work planning, work scheduling, worker training, work implementation and worker feedback. The presentation is based on a two-year international effort (sponsored by NEA/IAEA ISOE) to study effective work practices that reduce dose. Experts in this area believe that effective work selection and planning practices can substantially reduce occupational dose during refueling outages. For example, some plants represented in the expert group complete refueling outages in 12-18 days (Finland) with doses below 0,90 person-Sv. Other plants typically have 50-75 day outages with substantially higher site doses. The fundamental reasons for longer outages and higher occupational doses are examined. Good work management principles that have a proven track record of reducing occupational dose are summarized. Practical methods to reduce work duration and dose are explained. For example, scheduling at nuclear power plants can be improved by not only sequencing jobs on a time line but also including zone and resource-based considerations to avoid zone congestion and manpower delays. An ongoing, global, benchmarking effort is described which provides current duration and dose information for repetitive jobs to participating utilities world-wide. (author)

  8. Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Mei-ping; Liang, Chang-hong; Zhao, Zhen-jun; Liu, Hui; Li, Jing-lei; Zhang, Jin-e; Cui, Yan-hai; Yang, Lin; Liu, Qi-shun [Guangdong Academy of Medical Sciences, Guangdong General Hospital, Department of Radiology, Guangzhou (China); Ivanc, Thomas B.; Vembar, Mani [Philips Healthcare, CT Clinical Science, Highland Heights, OH (United States)

    2011-07-15

    There are a limited number of reports on the technical and clinical feasibility of prospective electrocardiogram (ECG)-gated multi-detector computed tomography (MDCT) in infants with congenital heart disease (CHD). To evaluate image quality and radiation dose at weight-based low-dose prospectively gated 256-slice MDCT angiography in infants with CHD. From November 2009 to February 2010, 64 consecutive infants with CHD referred for pre-operative or post-operative CT were included. All were scanned on a 256-slice MDCT system utilizing a low-dose protocol (80 kVp and 60-120 mAs depending on weight: 60 mAs for {<=}3 kg, 80 mAs for 3.1-6 kg, 100 mAs for 6.1-10 kg, 120 mAs for 10.1-15 kg). No serious adverse events were recorded. A total of 174 cardiac deformities, confirmed by surgery or heart catheterization, were studied. The sensitivity of MDCT for cardiac deformities was 97.1%; specificity, 99.4%; accuracy, 95.9%. The mean heart rate during scan was 136.7 {+-} 14.9/min (range, 91-160) with a corresponding heart rate variability of 2.8 {+-} 2.2/min (range, 0-8). Mean scan length was 115.3 {+-} 11.7 mm (range, 93.6-143.3). Mean volume CT dose index, mean dose-length product and effective dose were 2.1 {+-} 0.4 mGy (range, 1.5-2.8), 24.7 {+-} 5.9 mGy.cm (range, 14.7-35.8) and 1.6 {+-} 0.3 mSv (range, 1.1-2.5), respectively. Diagnostic-quality images were achieved in all cases. Satisfactory diagnostic quality for visualization of all/proximal/distal coronary artery segments was achieved in 88.4/98.8/80.0% of the scans. Low-dose prospectively gated axial 256-slice CT angiography is a valuable tool in the routine clinical evaluation of infants with CHD, providing a comprehensive three-dimensional evaluation of the cardiac anatomy, including the coronary arteries. (orig.)

  9. Hi-Res scan mode in clinical MDCT systems: Experimental assessment of spatial resolution performance.

    Science.gov (United States)

    Cruz-Bastida, Juan P; Gomez-Cardona, Daniel; Li, Ke; Sun, Heyi; Hsieh, Jiang; Szczykutowicz, Timothy P; Chen, Guang-Hong

    2016-05-01

    The introduction of a High-Resolution (Hi-Res) scan mode and another associated option that combines Hi-Res mode with the so-called High Definition (HD) reconstruction kernels (referred to as a Hi-Res/HD mode in this paper) in some multi-detector CT (MDCT) systems offers new opportunities to increase spatial resolution for some clinical applications that demand high spatial resolution. The purpose of this work was to quantify the in-plane spatial resolution along both the radial direction and tangential direction for the Hi-Res and Hi-Res/HD scan modes at different off-center positions. A technique was introduced and validated to address the signal saturation problem encountered in the attempt to quantify spatial resolution for the Hi-Res and Hi-Res/HD scan modes. Using the proposed method, the modulation transfer functions (MTFs) of a 64-slice MDCT system (Discovery CT750 HD, GE Healthcare) equipped with both Hi-Res and Hi-Res/HD modes were measured using a metal bead at nine different off-centered positions (0-16 cm with a step size of 2 cm); at each position, both conventional scans and Hi-Res scans were performed. For each type of scan and position, 80 repeated acquisitions were performed to reduce noise induced uncertainties in the MTF measurements. A total of 15 reconstruction kernels, including eight conventional kernels and seven HD kernels, were used to reconstruct CT images of the bead. An ex vivo animal study consisting of a bone fracture model was performed to corroborate the MTF results, as the detection of this high-contrast and high frequency task is predominantly determined by spatial resolution. Images of this animal model generated by different scan modes and reconstruction kernels were qualitatively compared with the MTF results. At the centered position, the use of Hi-Res mode resulted in a slight improvement in the MTF; each HD kernel generated higher spatial resolution than its counterpart conventional kernel. However, the MTF along the

  10. Spectrum of imaging findings on MDCT enterography in patients with small bowel tuberculosis

    International Nuclear Information System (INIS)

    Kalra, N.; Agrawal, P.; Mittal, V.; Kochhar, R.; Gupta, V.; Nada, R.; Singh, R.; Khandelwal, N.

    2014-01-01

    Abdominal tuberculosis (TB) is the sixth most common extrapulmonary site of involvement. The sites of involvement in abdominal tuberculosis, in descending order of frequency, are lymph nodes, genitourinary tract, peritoneal cavity, and gastrointestinal tract. The radiological armamentarium for evaluating tuberculosis of the small bowel (SBTB) includes barium studies (small bowel follow-through, SBFT), CT (multidetector CT, CT enterography, and CT enteroclysis), ultrasound (sonoenteroclysis), and magnetic resonance imaging (MRI; enterography and enteroclysis). In this review, we illustrate the abnormalities at MDCT enterography in 20 consecutive patients with SB TB and also describe extraluminal findings in these patients. MDCT enterography allows non-invasive good-quality assessment of well-distended bowel loops and the adjacent soft tissues. It displays the thickness and enhancement of the entire bowel wall in all three planes and allows examination of all bowel loops, especially the ileal loops, which are mostly superimposed. The terminal ileum and ileocaecal junction are the most common sites of small bowel involvement in intestinal TB. The most common abnormality is short-segment strictures with symmetrical concentric mural thickening and homogeneous mural enhancement. Other findings include lymphadenopathy, ascites, enteroliths, peritoneal thickening, and enhancement. In conclusion, MDCT enterography is a comprehensive technique for the evaluation of SB TB

  11. MDCT evaluation of potential living renal donor, prior to laparoscopic donor nephrectomy: What the transplant surgeon wants to know?

    International Nuclear Information System (INIS)

    Ghonge, Nitin P; Gadanayak, Satyabrat; Rajakumari, Vijaya

    2014-01-01

    As Laparoscopic Donor Nephrectomy (LDN) offers several advantages for the donor such as lesser post-operative pain, fewer cosmetic concerns and faster recovery time, there is growing global trend towards LDN as compared to open nephrectomy. Comprehensive pre-LDN donor evaluation includes assessment of renal morphology including pelvi-calyceal and vascular system. Apart from donor selection, evaluation of the regional anatomy allows precise surgical planning. Due to limited visualization during laparoscopic renal harvesting, detailed pre-transplant evaluation of regional anatomy, including the renal venous anatomy is of utmost importance. MDCT is the modality of choice for pre-LDN evaluation of potential renal donors. Apart from appropriate scan protocol and post-processing methods, detailed understanding of surgical techniques is essential for the Radiologist for accurate image interpretation during pre-LDN MDCT evaluation of potential renal donors. This review article describes MDCT evaluation of potential living renal donor, prior to LDN with emphasis on scan protocol, post-processing methods and image interpretation. The article laid special emphasis on surgical perspectives of pre-LDN MDCT evaluation and addresses important points which transplant surgeons want to know

  12. Hyperinflation and intrinsic positive end-expiratory pressure: less room to breathe.

    Science.gov (United States)

    Krieger, Bruce P

    2009-01-01

    Clinically, the symptoms and limited exercise capabilities of patients with chronic obstructive pulmonary disease (COPD) correlate better with changes in lung volumes than with airflow measurements. The realization of the clinical importance of hyperinflation has been overshadowed for decades by the use of forced expiratory volume during 1 s (FEV(1)) and the ratio of the FEV(1) to the forced expiratory vital capacity (FEV(1)/FVC) to categorize the severity and progression of COPD. Hyperinflation is defined as an elevation in the end-expiratory lung volume or functional residual capacity. When severe hyperinflation encroaches upon inspiratory capacity and limits vital capacity, it results in elevated intrinsic positive end-expiratory pressure (PEEPi) that places the diaphragm at a mechanical disadvantage and increases the work of breathing. Severe hyperinflation is the major physiologic cause of the resulting hypercarbic respiratory failure and patients' inability to transition (i.e. wean) from mechanical ventilatory support to spontaneous breathing. This paper reviews the basic physiologic principles of hyperinflation and its clinical manifestations as demonstrated by PEEPi. Also reviewed are the adverse effects of hyperinflation and PEEPi in critically ill patients with COPD, and methods for minimizing or counterbalancing these effects. Copyright 2009 S. Karger AG, Basel.

  13. Enhanced multidetector-row computed tomography (MDCT) in the diagnosis of acute appendicitis and its severity

    International Nuclear Information System (INIS)

    Miki, Tesshou; Ogata, Seiji; Uto, Mitsunobu; Nakazono, Toshihiro; Urata, Miyuki; Ishibe, Ryouhei; Shinyama, Shin; Nakajo, Masayuki

    2005-01-01

    The purpose of this study was to examine the accuracy of enhanced multidetector-row computed tomography (MDCT) in diagnosing acute appendicitis and its severity. Contrast-enhanced MD-CT 3.5 mm thick images of 23 control patients (A), and 64 patients with surgically proven acute appendicitis including 8 catarrhal (B), 28 phiegmonous (C), and 28 gangrenous (D) appendicitis patients were respectively analyzed. The number of observed major computed tomography (CT) findings for each patient group were as follows: enlarged (≥6 mm in maximum diameter) appendix (A: 5, B: 8, C: 28, D: 28), enhancement of the appendiceal wall; hyper (A: 3, B: 8, C: 27, D: 20), iso (A: 15, B: 0, C: 1, D: 2), hypo (A-C: 0, D: 4), and patched (A-C: 0, D: 2) enhancement, appendicolith (A, B: 0, C: 7, D: 13), dirty fat sign (A: 3, B: 1, C: 21, D: 28), localized ascites (A: 2, B: 0, C: 2, D: 11), and abscess formation (A-C: 0, D: 5). From the combinations of these findings, we could differentiate acute appendicitis from the control normal appendix with an accuracy of 99% and could diagnose the severity of acute appendicitis with accuracies of 92% for catarrhal appendicitis, 84% for phlegmonous appendicitis, and 92% for gangrenous appendicitis. We could also visually reconstruct the entire forms and positions of the appendices from the successive CT findings because of the high-resolution thin-slice MDCT images. MDCT is highly accurate in the diagnosis of acute appendicitis and its severity. (author)

  14. Chloral hydrate sedation in radiology: retrospective audit of reduced dose

    International Nuclear Information System (INIS)

    Bracken, Jennifer; Heaslip, Ingrid; Ryan, Stephanie

    2012-01-01

    Chloral hydrate (CH) is safe and effective for sedation of suitable children. The purpose of this study was to assess whether adequate sedation is achieved with reduced CH doses. We retrospectively recorded outpatient CH sedations over 1 year. We defined standard doses of CH as 50 mg/kg (infants) and 75 mg/kg (children >1 year). A reduced dose was defined as at least 20% lower than the standard dose. In total, 653 children received CH sedation (age, 1 month-3 years 10 months), 42% were given a reduced initial dose. Augmentation dose was required in 10.9% of all children, and in a higher proportion of children >1 year (15.7%) compared to infants (5.7%; P 1 year (95.3%; P = 0.03). A reduced initial dose had no negative effect on outcome (P = 0.19) or time to sedation. No significant complications were seen. We advocate sedation with reduced CH doses (40 mg/kg for infants; 60 mg/kg for children >1 year of age) for outpatient imaging procedures when the child is judged to be quiet or sleepy on arrival. (orig.)

  15. 64-MDCT angiography of blunt vascular injuries of the neck.

    Science.gov (United States)

    Chokshi, Falgun H; Munera, Felipe; Rivas, Luis A; Henry, Robert P; Quencer, Robert M

    2011-03-01

    CT angiography (CTA) using 64-MDCT enables timely evaluation of injuries associated with blunt neck trauma. The purpose of this article is to familiarize the reader with the most frequent CTA signs of blunt vascular injury. CTA is a valuable tool to detect blunt vascular injuries, especially using its multiplanar and 3D reconstruction capabilities.

  16. Effects of positive end-expiratory pressure on arthroscopic shoulder surgery under general anesthesia.

    Science.gov (United States)

    Ersoy, Ayşın; Çakırgöz, Mensure; Ervatan, Zekeriya; Kıran, Özlem; Türkmen, Aygen; Esenyel, Cem Zeki

    2016-01-01

    Our study is a prospective, randomized study on patients undergoing arthroscopic shoulder surgery in the beach-chair position to evaluate the effects of positive end-expiratory pressure (PEEP) on hemodynamic stability, providing a bloodless surgical field and surgical satisfaction. Fifty patients were divided into two groups. Group I (n=25) had zero end-expiratory pressure (ZEEP) administered under general anesthesia, and group II (n=25) had +5 PEEP administered. During surgery, intraarticular hemorrhage and surgical satisfaction were evaluated on a scale of 0-10. During surgery, at the 5th, 30th, 60th, and 90th minutes and at the end of surgery, heart rate, mean arterial pressure (MAP), and positive inspiratory pressure were recorded. At the end of the surgery, the amount of bleeding and duration of the operation were recorded. In group I, the duration of operation and amount of bleeding were found to be significantly greater than those in group II (pshoulder surgery in the beach-chair position reduces the amount of hemorrhage in the surgical field and thus increases surgical satisfaction without requiring the creation of controlled hypotension.

  17. Coronary artery bypass grafts: assessment of graft patency and native coronary artery lesions using 16-slice MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Stauder, Norbert I.; Drosch, Tanja; Claussen, Claus D.; Kopp, Andreas F. [Eberhard-Karls-University, Department of Diagnostic Radiology, Tuebingen (Germany); Kuettner, Axel [Friedrich-Alexander-University, Department of Diagnostic Radiology, Erlangen (Germany); Schroeder, Stephen; Beck, Torsten [Eberhard-Karls-University, Department of Internal Medicine, Division Cardiology, Tuebingen (Germany); Stauder, Heidrun [Eberhard-Karls-University, Department of Thoracic and Cardiovascular Surgery, Tuebingen (Germany); Blumenstock, Gunnar [Eberhard-Karls-University, Department of Medical Information Processing, Tuebingen (Germany)

    2006-11-15

    The objective of this study was to evaluate the accuracy of electrocardiography (ECG)-gated 16-slice multidetector-row computed tomography (MDCT) in detection of stenosis of bypass grafts and native coronary arteries in patients who have undergone coronary artery bypass grafting (CABG). ECG-gated contrast-enhanced MDCT using 12 x 0.75-mm collimation was performed in 20 patients with recurrent angina 4.75 years after undergoing CABG. A total of 50 grafts, 16 arterial and 34 venous, were examined. All graft and coronary segments were evaluated for stenosis in comparison with conventional coronary angiography (CCA). Among the 80 arterial graft segments, 62 could be assessed (77.5%). Sensitivity, specificity, and positive and negative predictive values for stenosis were 96.2%, 97.2%, 96.2%, and 97.2%, respectively. In a total of 180 venous graft segments, 167 could be assessed. Sensitivity, specificity, and positive and negative predictive values for stenosis were 98.5%, 93.9%, 91.8%, and 98.9%, respectively. MDCT could assess 179 of 260 native coronary artery segments (68.8%).Sensitivity, specificity, and positive and negative predictive values for stenosis were 92.1%, 76.9%, 87.5%, and 84.7%, respectively. Sixteen-slice MDCT provides excellent image quality and diagnostic accuracy in detection of graft and coronary artery lesions in patients with suspected graft dysfunction. (orig.)

  18. Osteoid osteoma and osteoid osteoma-mimicking lesions: biopsy findings, distinctive MDCT features and treatment by radiofrequency ablation

    Energy Technology Data Exchange (ETDEWEB)

    Becce, Fabio [Centre Hospitalier Universitaire Vaudois, Department of Diagnostic and Interventional Radiology, Lausanne (Switzerland); Universite Paris Descartes, Department of Radiology B, Hopital Cochin, AP-HP, Paris (France); Theumann, Nicolas [Centre Hospitalier Universitaire Vaudois, Department of Diagnostic and Interventional Radiology, Lausanne (Switzerland); Rochette, Antoine; Campagna, Raphael; Drape, Jean-Luc; Feydy, Antoine [Universite Paris Descartes, Department of Radiology B, Hopital Cochin, AP-HP, Paris (France); Larousserie, Frederique [Universite Paris Descartes, Department of Anatomic Pathology, Hopital Cochin, AP-HP, Paris (France); Cherix, Stephane; Mouhsine, Elyazid [Centre Hospitalier Universitaire Vaudois, Department of Orthopaedic and Traumatologic Surgery, Lausanne (Switzerland); Guillou, Louis [University Institute of Pathology, Centre Hospitalier Universitaire Vaudois, Lausanne (Switzerland); Anract, Philippe [Universite Paris Descartes, Department of Orthopaedic Surgery, Hopital Cochin, AP-HP, Paris (France)

    2010-10-15

    To report the biopsy findings of osteoid osteoma (OO) and OO-mimicking lesions, assess their distinctive multidetector computed tomography (MDCT) features and evaluate treatment by radiofrequency ablation (RFA). In this multicentric retrospective study, 80 patients (54 male, 26 female, mean age 24.1 years, range 5-48) with presumed (clinical and MDCT features) OO were treated by percutaneous RFA between May 2002 and June 2009. Per-procedural biopsies were always performed. The following MDCT features were assessed: skeletal distribution and location within the bone, size, central calcification, surrounding osteosclerosis and periosteal reaction. Clinical success of RFA was evaluated. Histopathological diagnoses were: 54 inconclusive biopsies, 16 OO, 10 OO-mimicking lesions (5 chronic osteomyelitis, 3 chondroblastoma, 1 eosinophilic granuloma, 1 fibrous dysplasia). OO-mimicking lesions were significantly greater in size (p = 0.001) and presented non-significant trends towards medullary location (p = 0.246), moderate surrounding osteosclerosis (p = 0.189) and less periosteal reaction (p = 0.197), compared with OO. Primary success for ablation of OO-mimicking lesions was 100% at 1 month, 85.7% at 6 and 12 months, and 66.7% at 24 months. Secondary success was 100%. Larger size, medullary location, less surrounding osteosclerosis and periosteal reaction on MDCT may help differentiate OO-mimicking lesions from OO. OO-mimicking lesions are safely and successfully treated by RFA. (orig.)

  19. Osteoid osteoma and osteoid osteoma-mimicking lesions: biopsy findings, distinctive MDCT features and treatment by radiofrequency ablation

    International Nuclear Information System (INIS)

    Becce, Fabio; Theumann, Nicolas; Rochette, Antoine; Campagna, Raphael; Drape, Jean-Luc; Feydy, Antoine; Larousserie, Frederique; Cherix, Stephane; Mouhsine, Elyazid; Guillou, Louis; Anract, Philippe

    2010-01-01

    To report the biopsy findings of osteoid osteoma (OO) and OO-mimicking lesions, assess their distinctive multidetector computed tomography (MDCT) features and evaluate treatment by radiofrequency ablation (RFA). In this multicentric retrospective study, 80 patients (54 male, 26 female, mean age 24.1 years, range 5-48) with presumed (clinical and MDCT features) OO were treated by percutaneous RFA between May 2002 and June 2009. Per-procedural biopsies were always performed. The following MDCT features were assessed: skeletal distribution and location within the bone, size, central calcification, surrounding osteosclerosis and periosteal reaction. Clinical success of RFA was evaluated. Histopathological diagnoses were: 54 inconclusive biopsies, 16 OO, 10 OO-mimicking lesions (5 chronic osteomyelitis, 3 chondroblastoma, 1 eosinophilic granuloma, 1 fibrous dysplasia). OO-mimicking lesions were significantly greater in size (p = 0.001) and presented non-significant trends towards medullary location (p = 0.246), moderate surrounding osteosclerosis (p = 0.189) and less periosteal reaction (p = 0.197), compared with OO. Primary success for ablation of OO-mimicking lesions was 100% at 1 month, 85.7% at 6 and 12 months, and 66.7% at 24 months. Secondary success was 100%. Larger size, medullary location, less surrounding osteosclerosis and periosteal reaction on MDCT may help differentiate OO-mimicking lesions from OO. OO-mimicking lesions are safely and successfully treated by RFA. (orig.)

  20. Chloral hydrate sedation in radiology: retrospective audit of reduced dose

    Energy Technology Data Exchange (ETDEWEB)

    Bracken, Jennifer [Children' s University Hospital, Radiology Department, Dublin (Ireland); Royal Children' s Hospital, Department of Medical Imaging, Parkville, Victoria (Australia); Heaslip, Ingrid; Ryan, Stephanie [Children' s University Hospital, Radiology Department, Dublin (Ireland)

    2012-03-15

    Chloral hydrate (CH) is safe and effective for sedation of suitable children. The purpose of this study was to assess whether adequate sedation is achieved with reduced CH doses. We retrospectively recorded outpatient CH sedations over 1 year. We defined standard doses of CH as 50 mg/kg (infants) and 75 mg/kg (children >1 year). A reduced dose was defined as at least 20% lower than the standard dose. In total, 653 children received CH sedation (age, 1 month-3 years 10 months), 42% were given a reduced initial dose. Augmentation dose was required in 10.9% of all children, and in a higher proportion of children >1 year (15.7%) compared to infants (5.7%; P < 0.001). Sedation was successful in 96.7%, and more frequently successful in infants (98.3%) than children >1 year (95.3%; P = 0.03). A reduced initial dose had no negative effect on outcome (P = 0.19) or time to sedation. No significant complications were seen. We advocate sedation with reduced CH doses (40 mg/kg for infants; 60 mg/kg for children >1 year of age) for outpatient imaging procedures when the child is judged to be quiet or sleepy on arrival. (orig.)

  1. Multi-detector computed tomography (MDCT imaging of cardiovascular effects of pulmonary embolism: What the radiologists need to know

    Directory of Open Access Journals (Sweden)

    Mohamed Aboul-fotouh E. Mourad

    2017-09-01

    Full Text Available Background: Patients with pulmonary embolism have high mortality and morbidity rate due to right heart failure and circulatory collapse leading to sudden death. Multi-detector computed tomography MDCT can efficiently evaluate the cardiovascular factors related to pulmonary embolism. Objectives: To evaluate the diagnostic accuracy of multi-detector computed tomography (MDCT in differentiation of between sever and non-severe pulmonary embolism groups depending on the associated cardiovascular parameters and create a simple reporting system. Patients & methods: Prospective study contained 145 patients diagnosed clinically pulmonary embolism. All patients were examined by combined electrocardiographically gated computed tomography pulmonary angiography-computed tomography venography (ECG-CTPA-CTV using certain imaging criteria in a systematic manner. Results: Our study revealed 95 and 55 non-severe and severe pulmonary embolism groups respectively. Many cardiovascular parameters related to pulmonary embolism shows significant p value and can differentiate between sever and non-severe pulmonary embolism patients include pulmonary artery diameter, intraventricular septum flattening, bowing, superior vena cava and Azygos vein diameters, right and left ventricular diameters. Conclusion: Multi-detector computed tomography (MDCT can be valuable to assess the severity of pulmonary embolism using the related cardiovascular parameters and leading the management strategy aim for best outcome. Keywords: Pulmonary embolism, MDCT, Cardiovascular, Computed tomography venography

  2. MDCT evaluation of potential living renal donor, prior to laparoscopic donor nephrectomy: What the transplant surgeon wants to know?

    Directory of Open Access Journals (Sweden)

    Nitin P Ghonge

    2014-01-01

    Full Text Available As Laparoscopic Donor Nephrectomy (LDN offers several advantages for the donor such as lesser post-operative pain, fewer cosmetic concerns and faster recovery time, there is growing global trend towards LDN as compared to open nephrectomy. Comprehensive pre-LDN donor evaluation includes assessment of renal morphology including pelvi-calyceal and vascular system. Apart from donor selection, evaluation of the regional anatomy allows precise surgical planning. Due to limited visualization during laparoscopic renal harvesting, detailed pre-transplant evaluation of regional anatomy, including the renal venous anatomy is of utmost importance. MDCT is the modality of choice for pre-LDN evaluation of potential renal donors. Apart from appropriate scan protocol and post-processing methods, detailed understanding of surgical techniques is essential for the Radiologist for accurate image interpretation during pre-LDN MDCT evaluation of potential renal donors. This review article describes MDCT evaluation of potential living renal donor, prior to LDN with emphasis on scan protocol, post-processing methods and image interpretation. The article laid special emphasis on surgical perspectives of pre-LDN MDCT evaluation and addresses important points which transplant surgeons want to know.

  3. Comparison of capability of dynamic O2-enhanced MRI and quantitative thin-section MDCT to assess COPD in smokers

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Keiko; Aoyama, Nobukazu; Onishi, Yumiko; Takenaka, Daisuke; Matsumoto, Sumiaki; Nishimura, Yoshihiro; Sugimura, Kazuro

    2012-01-01

    Purpose: The purpose of this study was to directly and prospectively compare the capability of dynamic O 2 -enhanced MRI and quantitatively assessed thin-section MDCT to assess smokers’ COPD in a large prospective cohort. Materials and methods: The GOLD criteria for smokers were used to classify 187 smokers into four clinical stage groups as follows: smokers without COPD (n = 56) and with mild (n = 54), moderate (n = 52) and severe or very severe COPD (n = 24). All smokers underwent dynamic O 2 -enhanced MRI, MDCT and pulmonary function tests. Mean relative enhancement ratio and mean wash-in time on MRI and CT-based functional lung volume (CT-based FLV) as well as the ratio of airway wall area to total airway area on MDCT were computationally calculated. Then, all indexes were significantly correlated with functional parameters. To determine the efficacy of all indexes for clinical stage classification, the indexes for the four clinical groups were statistically compared by using Tukey's honestly significant difference multiple comparison test. Results: All indexes had significant correlations with functional parameters (p 2 -enhanced MRI for assessment of COPD in smokers is potentially as efficacious as quantitatively assessed thin-section MDCT.

  4. Mammography at reduced doses: present performance and future possibilities

    International Nuclear Information System (INIS)

    Muntz, E.P.; Wilkinson, E.; George, F.W.

    1980-01-01

    Reduced dose mammography is assessed with the aid of very recent work. It is concluded that there are technical and clinical reasons for believing that the reduced dose systems and their interpreters should perform more effectively than their predecessors. Review of known technologic achievements suggests a possible 6 to 7 reduction factor from present screen-film mammography dose levels without sacficifing image quality. Reasonable estimates of representative doses presently achieved by both xeroradiography and screen-film systems are given. The screen-film value is about 3 times higher than some previous

  5. Normal appendix in adults: MDCT findings about the location, thickness and the presence or absence of intraluminal gas

    International Nuclear Information System (INIS)

    Oh, Kyoung Jin; Cho, June Sik; Shin, Kyung Sook; Kim, Ha Young; Lim, Sae Kyung; Ohm, Joon Young; Yoon, Chung Dae; Shin, Byung Seok

    2006-01-01

    We wanted to examine the usefulness of multi-detector CT (MDCT) with multiplanar reformations for evaluating the location, thickness and the presence or absence of intraluminal gas in the normal appendix of adults. From December 2004 to June 2005, we evaluated normal appendices in 427 consecutive adult patients who were scanned with 16-slice MDCT. All these patients had no clinical findings of appendicitis. There were 251 men and 176 women. The age range was 19-84 years (mean age: 55 years). The contrast-enhanced MDCT scans during the portal phase were obtained with 0.75 mm detector collimation and they were reviewed with using the multiplanar reconstruction images (3 mm section thickness). The MDCT images of normal appendices on a PACS monitor were retrospectively analyzed. We analyzed the location, thickness and the presence or absence of intraluminal gas by consensus of two abdominal radiologists. The positions of normal appendices were classified as type I (postileal and medial paracecal), type II (subcecal), type III (retrocecal and retrocolic or laterocolic), type IV (preileal and medical colic) and type V (lower pelvic cavity). The five types of appendiceal locations were as follows: type I (n = 187; 44%), type II (n 78; 18%), type III (n = 92, 22%), type IV (n = 39; 9%) and type V (n = 31; 7%). The appendiceal tips in 29 cases (7%) were unusually located in the right subhepatic space, the small bowel mesentery and the right adnexa. The mean thickness of 427 appendices was 5.8 ± 0.9 mm (range: 3.8-9.2 mm). The appendiceal mean thickness was 5.9 ± 0.9 mm in men and 5.7 ± 0.9 mm in women (ρ < 0.05). 384 (90%) of 427 appendices had intraluminal gas and 43 (10%) had no intraluminal gas, and their mean thickness was 5.9 mm (range: 3.8-9.2 mm) and 5.3 mm (3.8-7.3 mm), respectively (ρ < 0.05). MDCT with multiplanar reformations was useful for evaluating the location, thickness and the presence or absence of intraluminal gas in normal appendix of adults. These

  6. Facilitating coronary artery evaluation in MDCT using a 3D automatic vessel segmentation tool

    International Nuclear Information System (INIS)

    Fawad Khan, M.; Gurung, Jessen; Maataoui, Adel; Brehmer, Boris; Herzog, Christopher; Vogl, Thomas J.; Wesarg, Stefan; Dogan, Selami; Ackermann, Hanns; Assmus, Birgit

    2006-01-01

    The purpose of this study was to investigate a 3D coronary artery segmentation algorithm using 16-row MDCT data sets. Fifty patients underwent cardiac CT (Sensation 16, Siemens) and coronary angiography. Automatic and manual detection of coronary artery stenosis was performed. A 3D coronary artery segmentation algorithm (Fraunhofer Institute for Computer Graphics, Darmstadt) was used for automatic evaluation. All significant stenoses (>50%) in vessels >1.5 mm in diameter were protocoled. Each detection tool was used by one reader who was blinded to the results of the other detection method and the results of coronary angiography. Sensitivity and specificity were determined for automatic and manual detection as well as was the time for both CT-based evaluation methods. The overall sensitivity and specificity of the automatic and manual approach were 93.1 vs. 95.83% and 86.1 vs. 81.9%. The time required for automatic evaluation was significantly shorter than with the manual approach, i.e., 246.04±43.17 s for the automatic approach and 526.88±45.71 s for the manual approach (P<0.0001). In 94% of the coronary artery branches, automatic detection required less time than the manual approach. Automatic coronary vessel evaluation is feasible. It reduces the time required for cardiac CT evaluation with similar sensitivity and specificity as well as facilitates the evaluation of MDCT coronary angiography in a standardized fashion. (orig.)

  7. MDCT in the diagnosis of small-bowel obstruction by a retained ...

    African Journals Online (AJOL)

    assessment of complications such as abscess formation, fistula. MDCT in the diagnosis of small-bowel obstruction by a retained surgical swab. M. Bindapersad, M.B. Ch.B., F.C.Rad. (Diag.) N. Govender, M.B. Ch.B. Department of Radiology, Chris Hani Baragwanath Hospital and Faculty of Health Sciences, University of the ...

  8. Intra-individual comparison of different contrast media concentrations (300 mg, 370 mg and 400 mg iodine) in MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Behrendt, Florian F.; Keil, Sebastian; Plumhans, Cedric; Guenther, Rolf W. [RWTH Aachen University, Department of Diagnostic Radiology, University Hospital, Aachen (Germany); Pietsch, Hubertus; Jost, Gregor; Sieber, Martin A.; Seidensticker, Peter [Bayer Schering Pharma AG, Berlin (Germany); Mahnken, Andreas H. [RWTH Aachen University, Department of Diagnostic Radiology, University Hospital, Aachen (Germany); RWTH Aachen University, Applied Medical Engineering, Helmholtz-Institute for Biomedical Engineering, Aachen (Germany)

    2010-07-15

    To compare intra-individual contrast enhancement in multi-detector-row computed tomography (MDCT) using contrast media (CM) containing 300, 370 and 400 mg iodine per ml (mgI/ml). Six pigs underwent repeated chest MDCT using three different CM (iopromide 300, iopromide 370, iomeprol 400). An identical iodine delivery (IDR) rate of 1.5 gI/s and a constant total iodine dose of 300 mg/kg body weight were used. Dynamic CT were acquired at the level of the pulmonary artery, and the ascending and descending aorta. After the time enhancement curves were computed, the pulmonary and aortic peak enhancement, time to peak and plateau time above 300 HU were calculated. Intra-individual peak contrast enhancement was significantly higher for the 300 mgI/ml contrast medium compared with the 370 and 400 mgI/ml media: pulmonary trunk 595 HU vs 516 HU (p = 0.0093) vs 472HU (p = 0.0005), and aorta 505 HU vs 454 HU (p = 0.0008) vs 439 HU (p = 0.0001), respectively. Comparison of time to peaks showed no significant difference. Plateau times were significantly longer for the 300 mgI/ml than for the 370 and 400 mgI/ml CM at all anatomical sites. Given normalised IDR and total iodine burden, the use of CM with a standard concentration with 300 mg iodine/ml provides improved contrast enhancement compared with highly concentrated CM in the chest. (orig.)

  9. Relationship of end-expiratory pressure, lung volume, and /sup 99m/Tc-DTPA clearance

    International Nuclear Information System (INIS)

    Cooper, J.A.; van der Zee, H.; Line, B.R.; Malik, A.B.

    1987-01-01

    We investigated the dose-response effect of positive end-expiratory pressure (PEEP) and increased lung volume on the pulmonary clearance rate of aerosolized technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA). Clearance of lung radioactivity was expressed as percent decrease per minute. Base-line clearance was measured while anesthetized sheep (n = 20) were ventilated with 0 cmH 2 O end-expiratory pressure. Clearance was remeasured during ventilation at 2.5, 5, 10, 15, or 20 cmH 2 O PEEP. Further studies showed stepwise increases in functional residual capacity (FRC) (P less than 0.05) measured at 0, 2.5, 5, 10, 15, and 20 cmH 2 O PEEP. At 2.5 cmH 2 O PEEP, the clearance rate was not different from that at base line (P less than 0.05), although FRC was increased from base line. Clearance rate increased progressively with increasing PEEP at 5, 10, and 15 cmH 2 O (P less than 0.05). Between 15 and 20 cmH 2 O PEEP, clearance rate was again unchanged, despite an increase in FRC. The pulmonary clearance of aerosolized /sup 99m/Tc-DTPA shows a sigmoidal response to increasing FRC and PEEP, having both threshold and maximal effects. This relationship is most consistent with the hypothesis that alveolar epithelial permeability is increased by lung inflation

  10. Evaluation of dose exposure in 64-slice CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M. [University Hospital Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Buchgeister, M.; Klabunde, M. [University of Tuebingen, Institute of Medical Physics, Tuebingen (Germany)

    2007-10-15

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  11. Evaluation of dose exposure in 64-slice CT colonography

    International Nuclear Information System (INIS)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M.; Buchgeister, M.; Klabunde, M.

    2007-01-01

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  12. Clinical significance of pneumatosis intestinalis - correlation of MDCT-findings with treatment and outcome

    Energy Technology Data Exchange (ETDEWEB)

    Treyaud, Marc-Olivier; Duran, Rafael; Knebel, Jean-Francois; Meuli, Reto A.; Schmidt, Sabine [Lausanne University Hospital, Department of Diagnostic and Interventional Radiology, Lausanne (Switzerland); Zins, Marc [Fondation Hopital St Joseph, Department of Radiology, Paris (France)

    2017-01-15

    To evaluate the clinical significance of pneumatosis intestinalis (PI) including the influence on treatment and outcome. Two radiologists jointly reviewed MDCT-examinations of 149 consecutive emergency patients (53 women, mean age 64, range 21-95) with PI of the stomach (n = 4), small (n = 68) and/or large bowel (n = 96). PI extension, distribution and possibly associated porto-mesenteric venous gas (PMVG) were correlated with other MDCT-findings, risk factors, clinical management, laboratory, histopathology, final diagnosis and outcome. The most frequent cause of PI was intestinal ischemia (n = 80,53.7 %), followed by infection (n = 18,12.1 %), obstructive (n = 12,8.1 %) and non-obstructive (n = 10,6.7 %) bowel dilatation, unknown aetiologies (n = 8,5.4 %), drugs (n = 8,5.4 %), inflammation (n = 7,4.7 %), and others (n = 6,4 %). Neither PI distribution nor extension significantly correlated with underlying ischemia. Overall mortality was 41.6 % (n = 62), mostly related to intestinal ischemia (p = 0.003). Associated PMVG significantly correlated with underlying ischemia (p = 0.009), as did the anatomical distribution of PMVG (p = 0.015). Decreased mural contrast-enhancement was the only other MDCT-feature significantly associated with ischemia (p p < 0.001). Elevated white blood count significantly correlated with ischemia (p = 0.03). In emergency patients, ischemia remains the most common aetiology of PI, showing the highest mortality. PI with associated PMVG is an alerting sign. PI together with decreased mural contrast-enhancement indicates underlying ischemia. (orig.)

  13. Comparison of the bronchodilatation produced by inhalation of ipratropium bromide and salbutamol sequentially and in fixed dose combination in stable bronchial asthma patients

    Directory of Open Access Journals (Sweden)

    Mohan A

    2006-01-01

    Full Text Available Objectives : The combination of a 43-2 agonist and an anticholinergic agent is of-ten used to manage bronchial asthma. However, it is unclear whether these drugs should be given separately in sequence or in a fixed dose combination for maximum effect. Methods : 27 patients with stable bronchial asthma were given the above two drugs in two separate sessions one week apart. In one session they were given the above two drugs as a fixed dose combination and in the other session, they were given se-quentially with salbutamol following ipratropium after 30 minutes. Spirometry was performed at baseline and 15, 30 and 60 minutes after inhaling the second drug. Results : Both groups showed significant improvement in forced vital capacity (FVC, forced expiratory time in one second (FEV 1 , peak expiratory flow rate (PEFR and forced expiratory flow (FEF 25-75 from baseline upto one hour. FVC increased initially and then stabilized; however, the increase was more sustained in the group getting combination treatment. This group also showed a higher rise in FEV 1 (p=0.02. Both FEV 1 and FEF 25-75 decreased after 30 minutes in the group that received sequential therapy. PEFR increased continuously till 60 minutes in both groups and there was no significant difference between them (p=0.98. Interpretation and Conclusion: Both methods of drug dosing produce equivalent bronchodilation. Fixed dose combinations produced a more sustained rise in FVC and higher increase in FEV 1 . Hence fixed dose combinations are more effective short-term bronchodilators and give an added advantage of reducing the number of inhalers required, thus improv-ing compliance.

  14. Assessment of patient dose reduction when using AEC technique in toshiba 64 MDCT

    International Nuclear Information System (INIS)

    Khojali, Wadah Mohamed Ali.

    2016-03-01

    The aim of research is to evaluate the efficiency of AEC (SUREDOSE) used in Toshiba CT scanner in reducing patient radiation dose. 107 patients were studied from four CT scanners. Scan factors and radiation dose received during abdominal CT scan was registered between the contract phases of abdominal CT scan, where the arterial contrast phases was done with Routine Manual Protocol i.e. fixed mA and kVp regardless patient age, weight and reason of scan, while the vinous phase done using AEC. The mA values were considerably less in vinous phase than in the arterial phase for all hospitals with exceptional to hospital 4 where the mA values had increased. There were no variations between the two phases in the other scan factors (kVp. pitch, slice thickness, scan length), which indicates that the software was mainly changing the mA values. The mA also showed wide variations during venous phase as a result of the varying mA applied by the AEC for the different patient ages and weights. The data collection has showed that, the application of SURDOSE decreases that average mA by 56.6%, 61%6 and 56.6 for hospitals 1, 2, and 3 respectively. The reduction of the average of the CTD1_vol were 54.2%. 64.1% in hospital 1.2. and 3 respectively. The average DLPs were also less by 57.1%. 62.8%. 57.5% in hospital, 2, and 3 respectively between the phases. In hospital 4 one raw of the CT detector was not functioning this has disturbed the SURDOSE software. Leading to increase of the mA values and hence the patient radiation dose mA, CTD1_vol and DLP in this hospital increased by 47.7%, 54.3% and 42.8% respectively. This highlighted the risk of not applying the AEC correctly. The non application of this software was only due to lake of knowledge how to use it and the benefits of dose reduction associated with it. Application of this software is very useful and operator should be trained to use it in all CT exams. (Author)

  15. Inspiratory and expiratory computed tomographic volumetry for lung volume reduction surgery.

    Science.gov (United States)

    Morimura, Yuki; Chen, Fengshi; Sonobe, Makoto; Date, Hiroshi

    2013-06-01

    Three-dimensional (3D) computed tomographic (CT) volumetry has been introduced into the field of thoracic surgery, and a combination of inspiratory and expiratory 3D-CT volumetry provides useful data on regional pulmonary function as well as the volume of individual lung lobes. We report herein a case of a 62-year-old man with severe emphysema who had undergone lung volume reduction surgery (LVRS) to assess this technique as a tool for the evaluation of regional lung function and volume before and after LVRS. His postoperative pulmonary function was maintained in good condition despite a gradual slight decrease 2 years after LVRS. This trend was also confirmed by a combination of inspiratory and expiratory 3D-CT volumetry. We confirm that a combination of inspiratory and expiratory 3D-CT volumetry might be effective for the preoperative assessment of LVRS in order to determine the amount of lung tissue to be resected as well as for postoperative evaluation. This novel technique could, therefore, be used more widely to assess local lung function.

  16. Effects of dorsal and lateral decubitus on peak expiratory flow in healthy subjects

    Directory of Open Access Journals (Sweden)

    Heloisa H. Gianinis

    2013-10-01

    Full Text Available BACKGROUND: One of the measures of the pulmonary function is the peak expiratory flow (PEF that can be defined as the major flow obtained in an expiratory pressure after a complete inspiration to the level of the total lung capacity. This measure depends on the effort and strength of expiratory muscles, the airway diameter and the lung volume. OBJECTIVE: To compare the results of the peak expiratory flow in healthy male and female obtained in a seated position and dorsal decubitus (DD, right lateral decubitus (RLD and left lateral decubitus (LLD. METHOD: Thirty young subjects with mean age 22.7 years, healthy and non-smokers were included at the study, 15 of male sex. They did spirometry and IPAQ questionnaire to check the normal pulmonary function and physical activity level. The measures of PEF were performed in four positions, being performed 3 measures in which position, in a random order. Statistical analysis was performed according to Student's t test, with significance level set at 5%. RESULTS: There was a difference between the values obtained in sitting position(481±117.1 L/min with DD(453.2±116.3 L/min and RLD (454±112.9 L/min (p<0.05, however, did not find a significant difference between the sitting position and LLD (469±83 L/min. CONCLUSIONS: Body position affects the values of PEF, with decreasing values in DD and RLD. The LLD can be an alternative to optimize the expiratory flow in situations of constraint to the sitting position.

  17. Contribution of multi-detector row CT (MDCT) to decision making in the management of patients with small bowel obstruction or ileus

    International Nuclear Information System (INIS)

    Osada, Hisato; Watanabe, Wataru; Okada, Taketomo

    2007-01-01

    We retrospectively evaluated the contribution of multi-detector row CT (MDCT) to patient management decisions in 62 patients with small bowel obstruction or ileus. The sensitivity and specificity of MDCT diagnosis of small bowel obstruction with strangulation or closed loop were 78.9% (15/19) and 93.0% (40/43), respectively. In 19 patients with small bowel obstruction with strangulation or closed loop, the median interval between CT examination and the commencement of surgery was significantly longer in misdiagnosed patients than in those correctly diagnosed (43.3 vs. 4.5 hours, p<0.05). Only two patients displayed severe physical signs that required urgent surgical treatment. Our results suggest that MDCT plays a key role in the management of patients with small bowel obstruction. (author)

  18. Multidetector CT (MD-CT) in the diagnosis of uncertain open globe injuries

    Energy Technology Data Exchange (ETDEWEB)

    Hoffstetter, P.; Schreyer, A.G.; Jung, E.M.; Heiss, P.; Zorger, N. [Inst. fuer Roentgendiagnostik, Universitaetsklinikum Regensburg (Germany); Schreyer, C.I.; Framme, C. [Klink und Poliklinik fuer Augenheilkunde, Universitaetsklinikum Regensburg (Germany)

    2010-02-15

    Purpose: To evaluate the significance of multislice CT for the diagnosis of uncertain penetrating globe injuries. Materials and Methods: Based on a retrospective chart review between 2002 and 2007, we identified 59 patients presenting with severe ocular trauma with uncertain rupture of the globe due to massive subconjunctival and/or anterior chamber hemorrhage. The IOP (intraocular pressure) was within normal range in all patients. High resolution multidetector CT (MD-CT) scans (16 slice scans) with axial and coronar reconstructions were performed in all patients. The affected eye was examined for signs of penetrating injury such as abnormal eye shape, scleral irregularities, lens dislocation or intravitreal hemorrhages. Four experienced radiologists read the CT scans independently. Beside the diagnosis, the relevant morphological criteria and the optimal plane orientation (axial or coronar) were specified. The sensitivity, specificity, and negative and positive predictive value were calculated. Additionally the interobserver variability was determined by applying the Cohen's kappa test. Surgical sclera inspections were performed in all cases as a standard of reference. The evaluations of the CT examination were compared with the surgery reports. Results: 59 patients were evaluated (42 men, 17 women). The mean age was 29 years (range 7-91). In 17 patients a rupture of the globe was diagnosed during surgery. 12 of these 17 penetrating injuries (70.6%) were classified correctly by MDCT, 5 of the 17 (29.4%) were not detectable. 42 patients did not have an open globe injury. 41 of these patients were diagnosed correctly negative by MDCT, and one patient was classified false positive. This results in a sensitivity of 70% with a specificity of 98%. There was high inter-rater agreement with kappa values between 0.89-0.96. Most discrepancies were caused by wrong negative findings. The most frequent morphologic criteria for open globe injury were the deformation (n

  19. Influence of detector collimation on SNR in four different MDCT scanners using a reconstructed slice thickness of 5 mm

    International Nuclear Information System (INIS)

    Verdun, F.R.; Pachoud, M.; Monnin, P.; Valley, J.-F.; Noel, A.; Meuli, R.; Schnyder, P.; Denys, A.

    2004-01-01

    The purpose of this paper is to compare the influence of detector collimation on the signal-to-noise ratio (SNR) for a 5.0 mm reconstructed slice thickness for four multi-detector row CT (MDCT) units. SNRs were measured on Catphan test phantom images from four MDCT units: a GE LightSpeed QX/I, a Marconi MX 8000, a Toshiba Aquilion and a Siemens Volume Zoom. Five-millimetre-thick reconstructed slices were obtained from acquisitions performed using detector collimations of 2.0-2.5 mm and 5.0 mm, 120 kV, a 360 tube rotation time of 0.5 s, a wide range of mA and pitch values in the range of 0.75-0.85 and 1.25-1.5. For each set of acquisition parameters, a Wiener spectrum was also calculated. Statistical differences in SNR for the different acquisition parameters were evaluated using a Student's t-test (P<0.05). The influence of detector collimation on the SNR for a 5.0-mm reconstructed slice thickness is different for different MDCT scanners. At pitch values lower than unity, the use of a small detector collimation to produce 5.0-mm thick slices is beneficial for one unit and detrimental for another. At pitch values higher than unity, using a small detector collimation is beneficial for two units. One manufacturer uses different reconstruction filters when switching from a 2.5- to a 5.0-mm detector collimation. For a comparable reconstructed slice thickness, using a smaller detector collimation does not always reduce image noise. Thus, the impact of the detector collimation on image noise should be determined by standard deviation calculations, and also by assessing the power spectra of the noise. (orig.)

  20. Diagnostic methods to assess inspiratory and expiratory muscle strength

    Directory of Open Access Journals (Sweden)

    Pedro Caruso

    2015-04-01

    Full Text Available Impairment of (inspiratory and expiratory respiratory muscles is a common clinical finding, not only in patients with neuromuscular disease but also in patients with primary disease of the lung parenchyma or airways. Although such impairment is common, its recognition is usually delayed because its signs and symptoms are nonspecific and late. This delayed recognition, or even the lack thereof, occurs because the diagnostic tests used in the assessment of respiratory muscle strength are not widely known and available. There are various methods of assessing respiratory muscle strength during the inspiratory and expiratory phases. These methods are divided into two categories: volitional tests (which require patient understanding and cooperation; and non-volitional tests. Volitional tests, such as those that measure maximal inspiratory and expiratory pressures, are the most commonly used because they are readily available. Non-volitional tests depend on magnetic stimulation of the phrenic nerve accompanied by the measurement of inspiratory mouth pressure, inspiratory esophageal pressure, or inspiratory transdiaphragmatic pressure. Another method that has come to be widely used is ultrasound imaging of the diaphragm. We believe that pulmonologists involved in the care of patients with respiratory diseases should be familiar with the tests used in order to assess respiratory muscle function.Therefore, the aim of the present article is to describe the advantages, disadvantages, procedures, and clinical applicability of the main tests used in the assessment of respiratory muscle strength.

  1. MDCT Findings of Traumatic Adrenal Injury in Children

    International Nuclear Information System (INIS)

    Choi, Seung Joon; Kim, Jee Eun; Ryu, Il; Kim, Jin Joo; Choi, Hye Young

    2011-01-01

    We wanted to evaluate the MDCT findings and concomitant injuries of traumatic adrenal injury in children. Among 375 children who had undergone a MDCT scan for abdominal trauma during the recent five years at our institution, 27 children who had revealed adrenal injury on their CT scan were included in the study. We retrospectively evaluated the causes of the trauma, the patterns of adrenal injury, the associated CT findings and the concomitant injuries of the other organs in the abdomen. We identified 27 children (7.5%) (17 boys and 10 girls, mean age: 9.9 years, range: 2-18 years) with adrenal injury. The causes of adrenal injury were a traffic accident for 20 patients (74%), falls for four patients (15%) and blunt trauma for three patients (11%). The right adrenal gland was injured in 20 patients (74%), while the left adrenal gland was injured in three patients and bilateral involvement was noted in four patients. The patterns of adrenal injury were round or oval shaped hematoma in 23 lesions (74%), irregular hemorrhage with obliterating the gland in six lesions (19%) and active extravasation of contrast material from the adrenal region in two lesions (7%). Concomitant injuries were noted in 22 patients (81%), including 15 patients with liver laceration (56%), 11 patients with lung contusion (41%) and nine patients with renal injury (33%). The frequency of adrenal injury was 7.5%. The right adrenal gland was more frequently involved. Concomitant organ injury was noted 81% of the patients and the most frequently involved organ was the liver (56%)

  2. Angular on-line tube current modulation in multidetector CT examinations of children and adults: The influence of different scanning parameters on dose reduction

    International Nuclear Information System (INIS)

    Papadakis, Antonios E.; Perisinakis, Kostas; Damilakis, John

    2007-01-01

    The purpose of this study was to assess the potential of angular on-line tube current modulation on dose reduction in pediatric and adult patients undergoing multidetector computed tomography (MDCT) examinations. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-year-old, 5-year-old, 10-year-old, and adult were employed in the current study. Phantoms were scanned with the use of on-line tube current modulation (TCM). Percent dose reduction (%DR) factors achieved by applying TCM, were determined for standard protocols used for head and neck, shoulder, thorax, thorax and abdomen, abdomen, abdomen and pelvis, pelvis, and whole body examinations. A preliminary study on the application of TCM in MDCT examinations of adult patients was performed to validate the results obtained in anthropomorphic phantoms. Dose reduction was estimated as the percentage difference of the modulated milliamperes for each scan and the preset milliamperes prescribed by the scan protocol. The dose reduction in children was found to be much lower than the corresponding reduction achieved for adults. For helical scans the %DR factors, ranged between 1.6% and 7.4% for the neonate, 2.9% and 8.7% for the 1-year old, 2% and 6% for the 5-year-old, 5% and 10.9% for the 10-year-old, and 10.4% and 20.7% for the adult individual. For sequential scans the corresponding %DR factors ranged between 1.3% and 6.7%, 4.5% and 11%, 4.2% and 6.6%, 6.4% and 12.3%, and 8.9% and 23.3%, respectively. Broader beam collimations are associated with decreased %DR factors, when other scanning parameters are held constant. TCM did not impair image noise. In adult patients, the %DR values were found to be in good agreement with the corresponding results obtained in the anthropomorphic adult phantom. In conclusion, on-line TCM may be considered as a valuable tool for reducing dose in routine CT examinations of pediatric and adult patients. However, the dose reduction achieved with TCM

  3. Changes in forced expiratory volume in 1 second over time in COPD

    DEFF Research Database (Denmark)

    Vestbo, Jørgen; Edwards, Lisa D; Scanlon, Paul D

    2011-01-01

    A key feature of chronic obstructive pulmonary disease (COPD) is an accelerated rate of decline in forced expiratory volume in 1 second (FEV(1)), but data on the variability and determinants of this change in patients who have established disease are scarce.......A key feature of chronic obstructive pulmonary disease (COPD) is an accelerated rate of decline in forced expiratory volume in 1 second (FEV(1)), but data on the variability and determinants of this change in patients who have established disease are scarce....

  4. Differentiation between tuberculosis and lymphoma in mediastinal lymph nodes: Evaluation with contrast-enhanced MDCT

    International Nuclear Information System (INIS)

    Tang, S.-S.; Yang, Z.-G.; Deng, W.; Shao, H.; Chen, J.; Wen, L.-Y.

    2012-01-01

    Aim: To determine the specific imaging criteria on contrast-enhanced multidetector computed tomography (MDCT) for differentiating between tuberculosis and lymphoma in mediastinal lymph nodes. Materials and methods: The anatomical distribution and enhancement patterns of mediastinal lymph nodes on contrast-enhanced MDCT were reviewed in 37 patients with tuberculosis and 54 patients with lymphoma. Of the patients with lymphoma, 18 had Hodgkin's disease and 36 had non-Hodgkin's lymphoma. Results: Region 10R was involved more often in tuberculosis than in Hodgkin's disease and non-Hodgkin's lymphoma. Region 6 had a higher tendency to be affected in Hodgkin's disease and non-Hodgkin's lymphoma compared with tuberculosis. Tuberculosis showed peripheral enhancement in 78% of cases, frequently with a multilocular appearance, compared to Hodgkin's disease and non-Hodgkin's lymphoma, which showed peripheral enhancement in only 6 and 3% of cases, respectively. Homogeneous enhancement was more commonly seen in lymphoma (83% for Hodgkin's disease, and 83% for non-Hodgkin's lymphoma) than in tuberculosis (8%). In the determination of tuberculosis, results showed that when a peripheral enhancement pattern was seen, sensitivity was 78%, specificity was 96%, and accuracy was 89%. In the determination of lymphoma, results showed that when a homogeneous enhancement pattern was seen, sensitivity was 83%, specificity was 92%, and accuracy was 87%. Conclusion: The findings of the present study indicate that specific anatomical distribution and enhancement patterns of lymphadenopathy shown on contrast-enhanced MDCT can be useful in differentiating tuberculosis from lymphoma of mediastinal lymph nodes.

  5. Understanding chest radiographic anatomy with MDCT reformations

    Energy Technology Data Exchange (ETDEWEB)

    Sussmann, A.R. [Department of Radiology, Thoracic Imaging, NYU Langone Medical Center, New York, NY (United States); Ko, J.P., E-mail: jane.ko@nyumc.or [Department of Radiology, Thoracic Imaging, NYU Langone Medical Center, New York, NY (United States)

    2010-02-15

    Chest radiograph interpretation requires an understanding of the mediastinal reflections and anatomical structures. Computed tomography (CT) improves the learning of three-dimensional (3D) anatomy, and more recently multidetector CT (MDCT) technology has enabled the creation of high-quality reformations in varying projections. Multiplanar reformations (MPRs) of varying thickness in the coronal and sagittal projections can be created for direct correlation with findings on frontal and lateral chest radiographs, respectively. MPRs enable simultaneous visualization of the craniocaudal extent of thoracic structures while providing the anatomic detail that has been previously illustrated using cadaveric specimens. Emphasis will be placed on improving knowledge of mediastinal anatomy and reflections including edges, lines, and stripes that are visible on chest radiographs.

  6. Efficient stereological approaches for the volumetry of a normal or enlarged spleen from MDCT images

    Energy Technology Data Exchange (ETDEWEB)

    Mazonakis, Michalis; Stratakis, John; Damilakis, John [University of Crete, Department of Medical Physics, Faculty of Medicine, P.O. Box 2208, Iraklion, Crete (Greece)

    2015-06-01

    To introduce efficient stereological approaches for estimating the volume of a normal or enlarged spleen from MDCT. All study participants underwent an abdominal MDCT. The first group included 20 consecutive patients with splenomegaly and the second group consisted of 20 subjects with a normal spleen. Splenic volume estimations were performed using the stereological point counting method. Stereological assessments were optimized using the systematic slice sampling procedure. Planimetric measurements based on manual tracing of splenic boundaries on each slice were taken as reference values. Stereological analysis using five to eight systematically sampled slices provided enlarged splenic volume estimations with a mean precision of 4.9 ± 1.0 % in a mean time of 2.3 ± 0.4 min. A similar measurement duration and error was observed for normal splenic volume assessment using four to seven systematically selected slices. These stereological approaches slightly but insignificantly overestimated the volume of a normal and enlarged spleen compared to planimetry (P > 0.05) with a mean difference of -1.3 ± 4.3 % and -2.7 ± 5.2 %, respectively. The two methods were highly correlated (r ≥ 0.96). The variability of repeated stereological estimations was below 3.8 %. The proposed stereological approaches enable the rapid, reproducible, and accurate splenic volume estimation from MDCT data in patients with or without splenomegaly. (orig.)

  7. An expiratory assist during spontaneous breathing can compensate for endotracheal tube resistance.

    Science.gov (United States)

    Uchiyama, Akinori; Chang, Cheng; Suzuki, Shinya; Mashimo, Takashi; Fujino, Yuji

    2009-08-01

    Although inspiratory assist of spontaneous breathing in intubated patients is common, expiratory assist functions have rarely been reported. Effective expiratory support (ES) could be used to compensate for endotracheal tube (ETT) resistance during spontaneous breathing. In this study, we examined the performance of a new system designed to provide both inspiratory support (IS) and ES during spontaneous breathing with the goal of reducing the effective resistance of the ETT. The ES system consisted of a ventilator demand valve and a computer-controlled piston cylinder, which aspirated gas from the respiratory circuit during the expiratory phase. The movement of the piston was synchronized with spontaneous breathing. We compared the pressures at the tip of the ETT and in the breathing circuit during spontaneous breathing through an ETT of internal diameter (ID) 5 mm with that of an ETT with ID 8 mm in nine healthy adult male volunteers. The ventilatory mode was set to maintain a continuous airway pressure of 0 cm H(2)O. Three ventilator settings (no support, IS only, and IS plus ES) were compared using ID 5 mm ETT. We monitored pressure in the breathing circuit (P(aw)), ETT tip pressure (P(tip)), and respiratory flow. The P(tip) of the ID 5 mm ETT showed a large negative deflection during inspiration and a positive deflection during expiration without support. IS alone did not improve the respiratory pattern through the small ETT. However, IS plus ES resulted in negative P(aw) during expiration in addition to positive deflection of P(aw) during inspiration, making the pressure characteristics of P(tip) similar to those of ID 8 mm ETT. Moreover, IS plus ES produced a respiratory pattern through the ID 5 mm ETT that was similar to that through the ID 8 mm ETT. In this study of healthy volunteers, IS plus ES compensated for the airway resistance imposed by a ID 5.0 mm ETT to create pressure changes at the tip of the ETT similar to those of an ID 8.0 mm ETT.

  8. Anemia and the risk of contrast-induced nephropathy in patients with renal insufficiency undergoing contrast-enhanced MDCT

    International Nuclear Information System (INIS)

    Murakami, Ryusuke; Kumita, Shin-ichiro; Hayashi, Hiromitsu; Sugizaki, Ken-ichi; Okazaki, Emi; Kiriyama, Tomonari; Hakozaki, Kenta; Tani, Hitomi; Miki, Izumi; Takeda, Minako

    2013-01-01

    Purpose: The purpose of this study was to assess the effect of anemia on the incidence of contrast-induced nephropathy (CIN) in patients with renal impairment undergoing MDCT. Materials and methods: Institutional review board approval was waived for this retrospective review of 843 patients with stable renal insufficiency (eGFR between 15 and 60 mL/min) who had undergone contrast-enhanced MDCT. Baseline hematocrit and hemoglobin values were measured. Serum creatinine (SCr) was assessed at the baseline and at 48–72 h after contrast administration. Results: The overall incidence of CIN in the patient population with renal insufficiency was 6.9%. CIN developed in 7.8% (54 of 695) of anemic patients, and in 2.8% (4 of 148) of non-anemic patients (P = .027). After adjustment for confounders, low hemoglobin and low hematocrit values remained independent predictors of CIN (odds ratio 4.6, 95% CI 1.0–20.5, P = .046). Conclusions: Anemia is associated with a higher incidence of CIN in patients with renal insufficiency. Anemia is a potentially modifiable risk factor for CIN, and has an unfavorable impact on prognosis in patients with renal insufficiency undergoing contrast-enhanced MDCT

  9. Anemia and the risk of contrast-induced nephropathy in patients with renal insufficiency undergoing contrast-enhanced MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Ryusuke, E-mail: rywakana@nms.ac.jp; Kumita, Shin-ichiro; Hayashi, Hiromitsu; Sugizaki, Ken-ichi; Okazaki, Emi; Kiriyama, Tomonari; Hakozaki, Kenta; Tani, Hitomi; Miki, Izumi; Takeda, Minako

    2013-10-01

    Purpose: The purpose of this study was to assess the effect of anemia on the incidence of contrast-induced nephropathy (CIN) in patients with renal impairment undergoing MDCT. Materials and methods: Institutional review board approval was waived for this retrospective review of 843 patients with stable renal insufficiency (eGFR between 15 and 60 mL/min) who had undergone contrast-enhanced MDCT. Baseline hematocrit and hemoglobin values were measured. Serum creatinine (SCr) was assessed at the baseline and at 48–72 h after contrast administration. Results: The overall incidence of CIN in the patient population with renal insufficiency was 6.9%. CIN developed in 7.8% (54 of 695) of anemic patients, and in 2.8% (4 of 148) of non-anemic patients (P = .027). After adjustment for confounders, low hemoglobin and low hematocrit values remained independent predictors of CIN (odds ratio 4.6, 95% CI 1.0–20.5, P = .046). Conclusions: Anemia is associated with a higher incidence of CIN in patients with renal insufficiency. Anemia is a potentially modifiable risk factor for CIN, and has an unfavorable impact on prognosis in patients with renal insufficiency undergoing contrast-enhanced MDCT.

  10. MDCT evaluation of pulmonary embolism in children and young adults following a lateral tunnel Fontan procedure: optimizing contrast-enhancement techniques

    International Nuclear Information System (INIS)

    Prabhu, Sanjay P.; Mahmood, Soran; Sena, Laureen; Lee, Edward Y.

    2009-01-01

    Pulmonary embolism (PE) is a life-threatening thromboembolic complication in patients who have undergone a Fontan procedure for augmenting pulmonary blood flow in the setting of single-ventricle physiology. In patients following a Fontan procedure, lack of proper contrast agent mixing in the right atrium and sluggish, low-velocity blood flow within the Fontan circulation often results in suboptimal contrast enhancement within the pulmonary artery for evaluating PE. Unfortunately, there is a paucity of information describing the optimal contrast-enhancement technique with multidetector CT (MDCT) for evaluating PE in children and young adults following a Fontan procedure. We illustrate the MDCT imaging findings of suboptimal contrast enhancement within the pulmonary artery, which can be mistaken for PE, in patients following a lateral Fontan procedure, and we discuss MDCT techniques to optimize contrast enhancement within the pulmonary artery in these patients for evaluating PE. The MDCT imaging findings in pediatric and young adult patients following a lateral Fontan procedure and with clinically suspected PE are illustrated. We describe intravenous contrast agent injection techniques that can be used to optimize the contrast enhancement in the pulmonary artery in patients following a lateral Fontan procedure. The use of a suboptimal contrast-enhancement technique led to initial misdiagnosis and incomplete evaluation of PE in the three patients following a lateral Fontan procedure. Imaging in two patients showed that optimal evaluation of thrombosis in the Fontan pathway and PE in the pulmonary arteries can be successfully achieved with simultaneous upper- and lower-limb injections of contrast agent. This series demonstrates that suboptimal contrast enhancement can result in misdiagnosis or incomplete evaluation of PE in children and young adults following a lateral Fontan procedure. Careful attention to optimizing contrast enhancement during MDCT examination for

  11. Reverse Redistribution in Myocardial Perfusion Imaging: Revisited with 64-slice MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Kyung; Kim, Jeong Ho; Hwang, Kyung Hoon; Choi, In Suck; Choi, Soo Jin; Choe, Won Sick [Gachon University Gil Hospital, Incheon (Korea, Republic of); Yoon, Min Ki [Good Samaritan Hospital, Pohang (Korea, Republic of)

    2010-06-15

    The authors report myocardial perfusion imaging of a patient showing reverse redistribution (RR) and a 64-slice multidetector-row computed tomography (MDCT) with corresponding findings. The patient had subendocardial myocardial infarction (MI) with positive electrocardiogram (EMG) findings and elevated levels of cardiac isoenzymes. Experiencing this case emphasizes the importance of complementary correlation of a new diagnostic modality that helps us to understand the nature of RR.

  12. Whole-lung volume and density in spirometrically-gated inspiratory and expiratory CT in systemic sclerosis: correlation with static volumes at pulmonary function tests.

    Science.gov (United States)

    Camiciottoli, G; Diciotti, S; Bartolucci, M; Orlandi, I; Bigazzi, F; Matucci-Cerinic, M; Pistolesi, M; Mascalchi, M

    2013-03-01

    Spiral low-dose computed tomography (LDCT) permits to measure whole-lung volume and density in a single breath-hold. To evaluate the agreement between static lung volumes measured with LDCT and pulmonary function test (PFT) and the correlation between the LDCT volumes and lung density in restrictive lung disease. Patients with Systemic Sclerosis (SSc) with (n = 24) and without (n = 16) pulmonary involvement on sequential thin-section CT and patients with chronic obstructive pulmonary disease (COPD)(n = 29) underwent spirometrically-gated LDCT at 90% and 10% of vital capacity to measure inspiratory and expiratory lung volumes and mean lung attenuation (MLA). Total lung capacity and residual volume were measured the same day of CT. Inspiratory [95% limits of agreement (95% LoA)--43.8% and 39.2%] and expiratory (95% LoA -45.8% and 37.1%) lung volumes measured on LDCT and PFT showed poor agreement in SSc patients with pulmonary involvement, whereas they were in substantial agreement (inspiratory 95% LoA -14.1% and 16.1%; expiratory 95% LoA -13.5% and 23%) in SSc patients without pulmonary involvement and in inspiratory scans only (95% LoA -23.1% and 20.9%) of COPD patients. Inspiratory and expiratory LDCT volumes, MLA and their deltas differentiated both SSc patients with or without pulmonary involvement from COPD patients. LDCT lung volumes and density were not correlated in SSc patients with pulmonary involvement, whereas they did correlate in SSc without pulmonary involvement and in COPD patients. In restrictive lung disease due to SSc there is poor agreement between static lung volumes measured using LDCT and PFT and the relationship between volume and density values on CT is altered.

  13. 3D noise power spectrum applied on clinical MDCT scanners: effects of reconstruction algorithms and reconstruction filters

    Science.gov (United States)

    Miéville, Frédéric A.; Bolard, Gregory; Benkreira, Mohamed; Ayestaran, Paul; Gudinchet, François; Bochud, François; Verdun, Francis R.

    2011-03-01

    The noise power spectrum (NPS) is the reference metric for understanding the noise content in computed tomography (CT) images. To evaluate the noise properties of clinical multidetector (MDCT) scanners, local 2D and 3D NPSs were computed for different acquisition reconstruction parameters. A 64- and a 128-MDCT scanners were employed. Measurements were performed on a water phantom in axial and helical acquisition modes. CT dose index was identical for both installations. Influence of parameters such as the pitch, the reconstruction filter (soft, standard and bone) and the reconstruction algorithm (filtered-back projection (FBP), adaptive statistical iterative reconstruction (ASIR)) were investigated. Images were also reconstructed in the coronal plane using a reformat process. Then 2D and 3D NPS methods were computed. In axial acquisition mode, the 2D axial NPS showed an important magnitude variation as a function of the z-direction when measured at the phantom center. In helical mode, a directional dependency with lobular shape was observed while the magnitude of the NPS was kept constant. Important effects of the reconstruction filter, pitch and reconstruction algorithm were observed on 3D NPS results for both MDCTs. With ASIR, a reduction of the NPS magnitude and a shift of the NPS peak to the low frequency range were visible. 2D coronal NPS obtained from the reformat images was impacted by the interpolation when compared to 2D coronal NPS obtained from 3D measurements. The noise properties of volume measured in last generation MDCTs was studied using local 3D NPS metric. However, impact of the non-stationarity noise effect may need further investigations.

  14. The signature of fusion between the embryological derivatives of the first and second branchial arches within the ossicular chain in MDCT

    Directory of Open Access Journals (Sweden)

    Sherif Abdelmonem Shama

    2018-03-01

    Full Text Available The embryological precursors of the ossicular chain of the middle ear in humans are still a matter of debate. Both classical interpretation and dual-arch interpretation are strong hypothesis. The Aim of the work was to use the MDCT in assessment of the sites of expected fusion between the embryological derivatives of the first and second branchial arches within the ossicular chain. This study was conducted on 200 normal ears. Results: The junctional zones were considered as near vertically oriented faint lines running within the malleous and incus in the axial MDCT cuts. Using fine manual manipulation of the scan planes and widow leveling, the presence of these junctional zones was confirmed in 174 sides (87%. Conclusions: The presence of the junctional zones between embryological derivatives of the first and second branchial arches within the ossicular chain at MDCT basis could support the dual arch interpretation at least in most of humans. Whatever the classical or dual arch interpretations or both are correct, the signature of such fusion between embryological derivatives of the first and second branchial arches within the ossicular chain, should be considered as normal variant and should not be mistaken with ossicular erosions, fractures or dislocations. Keywords: First branchial arch, Second branchial arch, Ossicular chain, MDCT

  15. Quantitative assessment of lung volumes using multi-detector row computed tomography (MDCT) in patients with chronic obstructive pulmonary disease (COPD)

    International Nuclear Information System (INIS)

    Lee, Sang Min; Hur, Jin; Kim, Tae Hoon; Kim, Sang Jin; Kim, Hyung Jung

    2008-01-01

    To evaluate the clinical value of the multi-detector row computed tomography (MDCT) in the quantitative assessment of lung volumes and to assess the relationship between the MDCT results and disease severity as determined by a pulmonary function test (PFT) in Chronic Obstructive Pulmonary Disease (COPD) patients. We performed a PFT and MDCT on 39 COPD patients. Using the GOLD classifications, we divided the patients into three groups according to disease severity; stage I (mild, n = 10), stage II (moderate, n = 15), and stage III (severe, n = 14). Using the pulmo-CT software program, we measured the proportion of lung volumes with attenuation values below -910 and -950 HU. The mean FEV1 (% of predicted) and FEV1/FVC was 82.2 ± 2% and 66.2 ± 3% in stage I, 53.5 ± 11% and 52 ± 6% in stage II, and 32.3 ± 7% and 44.2% ± 13% in stage III, respectively. Differences in lung volume percentage at each of the thresholds (-910 and -950 HU) among the 3 stages were statistically significant (ρ < 0.01, ρ < 0.01) and correlated well with the FEV1 and FEV1/FVC (r = -0.803, r -0.766, r = -0.817, and r = -0.795, respectively). The volumetric measurement obtained by MDCT provides an accurate means of quantifying pulmonary emphysema

  16. Location of radiosensitive organs, measurement of absorbed dose to radiosensitive organs and use of bismuth shields in paediatric anthropomorphic phantoms

    International Nuclear Information System (INIS)

    Inkoom, S.

    2014-08-01

    The aim of this study was to investigate: firstly, (i) location of radiosensitive organs in the interior of four (4) paediatric anthropomorphic phantoms, and, secondly, (ii) effectiveness of single and double bismuth thyroid shields, distance between shield and phantom surface, during paediatric multi-detector computed tomography (MDCT) using fixed tube current (FTC) and automatic exposure control (AEC) on dose reduction and image quality. Four (4) paediatric anthropomorphic phantoms representing the equivalent of a newborn, 1-, 5-, and 10-y-old child underwent head, thorax and abdomen computed tomography (CT) scans. CT and magnetic resonance imaging scans of all children aged 0-16 y-old performed during a 5-y-period at the University Hospital of Heraklion, Crete, Greece were reviewed, and five hundred and three (503) were found to be eligible for normal anatomy. Anterior-posterior and lateral dimensions of twelve (12) of the above children closely matched that of the phantoms' thoracic and abdominal region in each four (4) phantoms. The mid-sagittal plane (MSP) and mid-coronal plane (MCP) were drawn on selected matching axial images of patients and phantoms. Multiple points outlining large radiosensitive organs and centres of small organs in patient images were identified at each slice level and their orthogonal distances from the MSP and MCP were measured. The outlines and centres of all radiosensitive organs were reproduced using the coordinates of each organ on the corresponding phantom's transverse images. The four (4) phantoms were also subjected to routine head and neck, neck and thorax CT scans on a 16-slice CT system. Each phantom was first scanned with both FTC and AEC for with and without bismuth shields. Each scan was repeated ten (10) times to increase thermoluminescent dosimeters (TLDs) signal and reduce measurement statistical error. For neck CT, the effect of using single and double thickness of bismuth shields and 1-3 cm cotton spacers

  17. Strategies to reduce radiation dose in cardiac PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tung Hsin; Wu, Nien-Yun [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan (China); Wang, Shyh-Jen [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan (China); Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei, Taiwan (China); Wu, Jay [Institute of Radiological science, Central Taiwan University of Science and Technology, Taichung, Taiwan (China); Mok, Greta S.P. [Department of Electrical and Electronics Engineering, Faculty of Science and Technology, University of Macau, Macau (China); Yang, Ching-Ching, E-mail: g39220003@yahoo.com.tw [Department of Radiological Technology, Tzu Chi College of Technology, 880, Sec.2, Chien-kuo Rd. Hualien 970, Taiwan (China); Huang, Tzung-Chi, E-mail: tzungchi.huang@mail.cmu.edu.tw [Department of Biomedical Imaging and Radiological Science, China Medical University, No.91 Hsueh-Shih Road, Taichung 40402, Taiwan (China)

    2011-08-21

    Background: Our aim was to investigate CT dose reduction strategies on a hybrid PET/CT scanner for cardiac applications. Materials: Image quality and dose estimation of different CT scanning protocols for CT coronary angiography (CTCA), and CT-based attenuation correction for PET imaging were investigated. Fifteen patients underwent CTCA, perfusion PET imaging at rest and under stress, and FDG PET for myocardial viability. These patients were divided into three groups based on the CTCA technique performed: retrospectively gated helical (RGH), ECG tube current modulation (ETCM), and prospective gated axial (PGA) acquisitions. All emission images were corrected for photon attenuation using CT images obtained by default setting and an ultra-low dose CT (ULDCT) scan. Results: Radiation dose in RGH technique was 22.2{+-}4.0 mSv. It was reduced to 10.95{+-}0.82 and 4.13{+-}0.31 mSv using ETCM and PGA techniques, respectively. Radiation dose in CT transmission scan was reduced by 96.5% (from 4.53{+-}0.5 to 0.16{+-}0.01 mSv) when applying ULDCT as compared to the default CT. No significant difference in terms of image quality was found among various protocols. Conclusion: The proposed CT scanning strategies, i.e. ETCM or PGA for CTCA and ULDCT for PET attenuation correction, could reduce radiation dose up to 47% without degrading imaging quality in an integrated cardiac PET/CT coronary artery examination.

  18. Asbestos Surveillance Program Aachen (ASPA): initial results from baseline screening for lung cancer in asbestos-exposed high-risk individuals using low-dose multidetector-row CT

    International Nuclear Information System (INIS)

    Das, Marco; Muehlenbruch, Georg; Mahnken, Andreas H.; Guenther, Rolf W.; Wildberger, Joachim E.; Hering, K.G.; Sirbu, H.; Zschiesche, W.; Knoll, Lars; Felten, Michael K.; Kraus, Thomas

    2007-01-01

    The purpose of this study was to assess the prevalence of lung cancer in a high-risk asbestos-exposed cohort using low-dose MDCT. Of a population of 5,389 former power-plant workers, 316 were characterized as individuals at highest risk for lung cancer according to a lung-cancer risk model including age, asbestos exposure and smoking habits. Of these 316, 187 (mean age: 66.6 years) individuals were included in a prospective trial. Mean asbestos exposure time was 29.65 years and 89% were smokers. Screening was performed on a 16-slice MDCT (Siemens) with low-dose technique (10/20 mAs eff. ; 1 mm/0.5 mm increment). In addition to soft copy PACS reading analysis on a workstation with a dedicated lung analysis software (LungCARE; Siemens) was performed. One strongly suspicious mass and eight cases of histologically proven lung cancer were found plus 491 additional pulmonary nodules (average volume: 40.72 ml, average diameter 4.62 mm). Asbestos-related changes (pleural plaques, fibrosis) were visible in 80 individuals. Lung cancer screening in this high-risk cohort showed a prevalence of lung cancer of 4.28% (8/187) at baseline screening with an additional large number of indeterminate pulmonary nodules. Low-dose MDCT proved to be feasible in this highly selected population. (orig.)

  19. Sinonasal imaging after Caldwell-Luc surgery: MDCT findings of an abandoned procedure in times of functional endoscopic sinus surgery

    International Nuclear Information System (INIS)

    Nemec, Stefan Franz; Peloschek, Philipp; Koelblinger, Claus; Mehrain, Sheida; Krestan, Christian Robert; Czerny, Christian

    2009-01-01

    Background and purpose: Today, functional endoscopic sinus surgery (FESS) is performed in most of the patients with sinonasal inflammatory disease. The postoperative imaging findings of FESS in multidetector computed tomography (MDCT) considerably differ from those of historic Caldwell-Luc (CL) maxillary sinus surgery which is an uncommon procedure today. Thus, the postoperative CL imaging findings may lead to diagnostic confusion and misinterpretation. Therefore, this study explicitly presents the MDCT findings of post-CL patients which have not been described previously. Methods: Twenty-eight patients with clinically suspected sinusitis and documented history of CL-procedure underwent 16 row MDCT (MDCT Mx8000 IDT Philips) with multiplanar reconstructions of the paranasal sinuses in the axial plane. The following parameters were used: 140 kV, 50 mAs; 16 mm x 0.75 mm detector collimation; 1 mm reconstructed slice thickness; 0.5 mm increment. The studies were reconstructed with a bone algorithm (W3000/L600; 1 mm slice thickness) in axial plane and coronal plane (3 mm slice thickness). The images were retrospectively evaluated for the presence of normal surgery-related and pathological findings. Results: Surgery-related imaging characteristics presented as follows: an anterior and a medial bony wall defect and sclerosis and sinus wall thickening were observed in all 28/28 cases (100%). Collaps of the sinus cavity was seen in 26/28 cases (92.9%). Furthermore, inflammatory disease of the operated sinus(es) was found in 23/28 cases (82.1%): 14/28 patients (50%) had inflammatory mucosal thickening of the operated sinus(es) as well as of other sinonasal cavities and 9/28 patients (32.1%) had inflammatory mucosal thickening limited to the operated sinus(es). A postoperative mucocele was depicted in 3/28 cases (10.7%). 2/28 patients (7.1%) showed neither maxillary nor other mucosal swelling. Conclusion: MDCT with multiplanar reconstructions is a precise method to evaluate

  20. Cystic lung disease: a comparison of cystic size, as seen on expiratory and inspiratory HRCT scans

    International Nuclear Information System (INIS)

    Lee, Ki Nam; Yoon, Seong Kuk; Nam, Kyung Jin; Choi, Seok Jin; Goo, Jin Mo

    2000-01-01

    To determine the effects of respiration on the size of lung cysts by comparing inspiratory and expiratory high-resolution CT (HRCT) scans. The authors evaluated the size of cystic lesions, as seen on paired inspiratory and expiratory HRCT scans, in 54 patients with Langerhans cell histiocytosis (n = 3), pulmonary lymphangiomyomatosis (n = 4), confluent centrilobular emphysema (n = 9), paraseptal emphysema and bullae (n = 16), cystic bronchiectasis (n = 13), and honeycombing (n = 9). Using paired inspiratory and expiratory HRCT scans obtained at the corresponding anatomic level, a total of 270 cystic lesions were selected simultaneously on the basis of five lesions per lung disease. Changes in lung cyst size observed during respiration were assessed by two radiologists. In a limited number of cases (n = 11), pathologic specimens were obtained by open lung biopsy or lobectomy. All cystic lesions in patients with Langerhans cell histiocytosis, lymphangiomyomatosis, cystic bronchiectasis, honeycombing, and confluent centrilobular emphysema became smaller on expiration, but in two cases of paraseptal emphysema and bullae there was no change. In cases in which expiratory CT scans indicate that cysts have become smaller, cystic lesions may communicate with the airways. To determine whether, for cysts and cystic lesions, this connection does in fact exist, paired inspiratory and expiratory HRCT scans are necessary

  1. Cystic lung disease: a comparison of cystic size, as seen on expiratory and inspiratory HRCT scans

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ki Nam; Yoon, Seong Kuk; Nam, Kyung Jin [Donga University College of Medicine, Pusan (Korea, Republic of); Choi, Seok Jin [Inje University College of Medicine, Gimhae (Korea, Republic of); Goo, Jin Mo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2000-06-01

    To determine the effects of respiration on the size of lung cysts by comparing inspiratory and expiratory high-resolution CT (HRCT) scans. The authors evaluated the size of cystic lesions, as seen on paired inspiratory and expiratory HRCT scans, in 54 patients with Langerhans cell histiocytosis (n = 3), pulmonary lymphangiomyomatosis (n = 4), confluent centrilobular emphysema (n = 9), paraseptal emphysema and bullae (n = 16), cystic bronchiectasis (n = 13), and honeycombing (n = 9). Using paired inspiratory and expiratory HRCT scans obtained at the corresponding anatomic level, a total of 270 cystic lesions were selected simultaneously on the basis of five lesions per lung disease. Changes in lung cyst size observed during respiration were assessed by two radiologists. In a limited number of cases (n = 11), pathologic specimens were obtained by open lung biopsy or lobectomy. All cystic lesions in patients with Langerhans cell histiocytosis, lymphangiomyomatosis, cystic bronchiectasis, honeycombing, and confluent centrilobular emphysema became smaller on expiration, but in two cases of paraseptal emphysema and bullae there was no change. In cases in which expiratory CT scans indicate that cysts have become smaller, cystic lesions may communicate with the airways. To determine whether, for cysts and cystic lesions, this connection does in fact exist, paired inspiratory and expiratory HRCT scans are necessary.

  2. Thoracoabdominal mobility evaluation by photogrammetry in newborns after expiratory flow increase technique

    Directory of Open Access Journals (Sweden)

    Júlia Isabel de Araújo Guerra

    Full Text Available Abstract Introduction: Expiratory flow increase is a maneuver of respiratory physical therapy that promotes flow direction to the upper airways however, when applied in newborns, it may result in changes of thoracoabdominal mobility. Objective: To evaluate the thoracoabdominal mobility by photogrammetry in newborns after expiratory flow increase technique. Methods: Experimental blind study performed with newborns in supine position on a support table with upper limbs flexed, abducted and externally rotated and hip flexed at 110°. Adhesive markers were allocated for geometric delimitation of the thoracoabdominal compartment and expiratory flow increase technique was performed for 5 minutes with the therapist’s hands on the thorax and abdomen. Newborns were filmed before and after the maneuver and the frames were analyzed in AutoCAD® software by a blinded investigator at the time of the procedure. The largest and the smallest thoracoabdominal area were expressed in cm2 and the mean values were compared between two moments (pre and post maneuver by paired t test. Results: Twenty newborns with a mean age of 39 weeks were included. Before the maneuver, thoracoabdominal area was 56.1 cm2 during expiration and 59.7 cm2 during inspiration, and after the maneuver the value was 56.2 cm2 during expiration and 59.8 cm2 during inspiration, with no statistical difference between before and after (p = 0.97, p = 0.92, respectively. Conclusion: Results demonstrate that expiratory flow increase technique does not seem to change thoracoabdominal mobility of healthy newborns.

  3. Focal airtrapping at expiratory high-resolution CT: comparison with pulmonary function tests

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Hast, J.; Heussel, C.P.; Mildenberger, P.; Thelen, M.; Schlegel, J.

    2000-01-01

    This study was undertaken to determine prevalence, extent, and severity of focal airtrapping at expiratory high-resolution CT, and to compare focal airtrapping with age, gender, pulmonary function tests, and blood gas analysis. Two-hundred seventeen patients with and without pulmonary disease underwent paired inspiratory/expiratory high-resolution CT. Six scan pairs with corresponding scan levels were visually assessed for focal - not diffuse - airtrapping using a four-point scale. Pulmonary function tests and blood gas analysis were available for correlation in all patients (mean interval 5 days). Focal airtrapping with lower lung predominance was observed in 80 % of patients. Twenty-six of 26 patients with restrictive lung function impairment exhibited focal airtrapping (mean score 2.4), whereas only 72 of 98 (74 %) patients with obstruction did (mean score 1.5; p < 0.05). Fifty-eight of 70 (83 %) patients with normal lung function (mean score 1.8) and 19 of 23 (83 %) patients with mixed impairment (mean score 1.8) had focal airtrapping. Focal airtrapping showed negative correlations with static lung volumes (-0.27 to -0.37; p < 0.001) in all patients and moderate positive correlations with dynamic parameters (0.3-0.4; p < 0.001) in patients with obstruction. No significant correlations were found with age, gender, and blood gas analysis. Visual assessment of focal - not diffuse - airtrapping at expiratory high-resolution CT does not correlate with physiological evidence of obstruction as derived from pulmonary function tests since the perception of focal airtrapping requires an adequate expiratory increase in lung density. (orig.)

  4. Decreased peak expiratory flow in pediatric passive smokers

    Directory of Open Access Journals (Sweden)

    Fitri Yanti

    2011-08-01

    Full Text Available Background Indonesia ranks fifth among countries with the highest aggregate levels of tobacco consumption in the world. Infants and children exposed to environmental tobacco smoke have increased rates of asthma, respiratory and ear infections, as well as reduced lung function. The effects of tobacco smoke exposure on lung function in children have been reported to be dependent on the source of smoke and the length and dose of exposure. Lung function may also be affected by a child’s gender and asthma status. Objective To compare peak expiratory flow (PEF in pediatric passive smokers to that of children not exposed to second hand smoke, and to define factors that may affect PEF in passive smokers. Methods In August 2009 we conducted a cross-sectional study at an elementary school in the Langkat district. Subjects were aged 6 to 12 years, and divided into two groups: passive smokers and those not exposed to secondhand smoke. Subjects’ PEFs were measured with a Mini-Wright peak flow meter. Measurements were performed in triplicate with the highest value recorded as the PEF. Demographic data including age, sex, weight, height, family income, parental education levels and occupations were obtained through questionnaires. Results Of the 170 participants, 100 were passive smokers and 70 were not exposed to secondhand smoke. Age distribution, weight and height were similar in both groups. We observed a significant difference in PEFs between the group of passive smokers and the group not exposed to secondhand smoke, 211.3 L/minute (SD 61.08 and 242.7 L/minute (SD 77.09, respectively (P < 0.005. The number of years of exposure to smoke (P = 0.079 and the number of cigarettes smoked daily in the household (P = 0.098 did not significantly influence PEF. Conclusion The PEF in pediatric passive smokers was significantly lower than that of children not exposed to secondhand smoke. PEF in passive smokers was not influenced by the number of years of smoke

  5. Abdominal Hernias, Giant Colon Diverticulum, GIST, Intestinal Pneumatosis, Colon Ischemia, Cold Intussusception, Gallstone Ileus, and Foreign Bodies: Our Experience and Literature Review of Incidental Gastrointestinal MDCT Findings

    Science.gov (United States)

    Gatta, G.; Rella, R.; Donatello, D.; Falco, G.; Grassi, R.

    2017-01-01

    Incidental gastrointestinal findings are commonly detected on MDCT exams performed for various medical indications. This review describes the radiological MDCT spectrum of appearances already present in the past literature and in today's experience of several gastrointestinal acute conditions such as abdominal hernia, giant colon diverticulum, GIST, intestinal pneumatosis, colon ischemia, cold intussusception, gallstone ileus, and foreign bodies which can require medical and surgical intervention or clinical follow-up. The clinical presentation of this illness is frequently nonspecific: abdominal pain, distension, nausea, fever, rectal bleeding, vomiting, constipation, or a palpable mass, depending on the disease. A proper differential diagnosis is essential in the assessment of treatment and in this case MDCT exam plays a central rule. We wish that this article will familiarize the radiologist in the diagnosis of this kind of incidental MDCT findings for better orientation of the therapy. PMID:28638830

  6. Abdominal Hernias, Giant Colon Diverticulum, GIST, Intestinal Pneumatosis, Colon Ischemia, Cold Intussusception, Gallstone Ileus, and Foreign Bodies: Our Experience and Literature Review of Incidental Gastrointestinal MDCT Findings.

    Science.gov (United States)

    Di Grezia, G; Gatta, G; Rella, R; Donatello, D; Falco, G; Grassi, R; Grassi, R

    2017-01-01

    Incidental gastrointestinal findings are commonly detected on MDCT exams performed for various medical indications. This review describes the radiological MDCT spectrum of appearances already present in the past literature and in today's experience of several gastrointestinal acute conditions such as abdominal hernia, giant colon diverticulum, GIST, intestinal pneumatosis, colon ischemia, cold intussusception, gallstone ileus, and foreign bodies which can require medical and surgical intervention or clinical follow-up. The clinical presentation of this illness is frequently nonspecific: abdominal pain, distension, nausea, fever, rectal bleeding, vomiting, constipation, or a palpable mass, depending on the disease. A proper differential diagnosis is essential in the assessment of treatment and in this case MDCT exam plays a central rule. We wish that this article will familiarize the radiologist in the diagnosis of this kind of incidental MDCT findings for better orientation of the therapy.

  7. Improved MDCT monitoring of pelvic myeloma bone disease through the use of a novel longitudinal bone subtraction post-processing algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Horger, Marius; Thaiss, Wolfgang M.; Nikolaou, Konstantin; Kloth, Christopher [Eberhard-Karls-University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Ditt, Hendrik [Sector Imaging and Interventional Radiology, Siemens AG Healthcare, Forchheim (Germany); Weisel, Katja [Eberhard-Karls-University Tuebingen, Department of Internal Medicine II, Tuebingen (Germany); Fritz, Jan [Johns Hopkins University School of Medcine, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Liao, Shu [Siemens Medical Solutions, Malvern, PA (United States)

    2017-07-15

    To evaluate the diagnostic performance of a novel CT post-processing software that generates subtraction maps of baseline and follow-up CT examinations in the course of myeloma bone lesions. This study included 61 consecutive myeloma patients who underwent repeated whole-body reduced-dose MDCT at our institution between November 2013 and June 2015. CT subtraction maps classified a progressive disease (PD) vs. stable disease (SD)/remission. Bone subtraction maps (BSMs) only and in combination with 1-mm (BSM+) source images were compared with 5-mm axial/MPR scans. Haematological response categories at follow-up were: complete remission (n = 9), very good partial remission (n = 2), partial remission (n = 17) and SDh (n = 19) vs. PDh (n = 14). Five-millimetre CT scan yielded PD (n = 14) and SD/remission (n = 47) whereas bone subtraction + 1-mm axial scans (BSM+) reading resulted in PD (n = 18) and SD/remission (n = 43). Sensitivity/ specificity/accuracy for 5-mm/1-mm/BSM(alone)/BSM + in ''lesion-by-lesion'' reading was 89.4 %/98.9 %/98.3 %/ 99.5 %; 69.1 %/96.9 %/72 %/92.1 % and 83.8 %/98.4 %/92.1 %/98.3 %, respectively. The use of BSM+ resulted in a change of response classification in 9.8 % patients (n = 6) from SD to PD. BSM reading is more accurate for monitoring myeloma compared to axial scans whereas BSM+ yields similar results with 1-mm reading (gold standard) but by significantly reduced reading time. (orig.)

  8. Improved MDCT monitoring of pelvic myeloma bone disease through the use of a novel longitudinal bone subtraction post-processing algorithm

    International Nuclear Information System (INIS)

    Horger, Marius; Thaiss, Wolfgang M.; Nikolaou, Konstantin; Kloth, Christopher; Ditt, Hendrik; Weisel, Katja; Fritz, Jan; Liao, Shu

    2017-01-01

    To evaluate the diagnostic performance of a novel CT post-processing software that generates subtraction maps of baseline and follow-up CT examinations in the course of myeloma bone lesions. This study included 61 consecutive myeloma patients who underwent repeated whole-body reduced-dose MDCT at our institution between November 2013 and June 2015. CT subtraction maps classified a progressive disease (PD) vs. stable disease (SD)/remission. Bone subtraction maps (BSMs) only and in combination with 1-mm (BSM+) source images were compared with 5-mm axial/MPR scans. Haematological response categories at follow-up were: complete remission (n = 9), very good partial remission (n = 2), partial remission (n = 17) and SDh (n = 19) vs. PDh (n = 14). Five-millimetre CT scan yielded PD (n = 14) and SD/remission (n = 47) whereas bone subtraction + 1-mm axial scans (BSM+) reading resulted in PD (n = 18) and SD/remission (n = 43). Sensitivity/ specificity/accuracy for 5-mm/1-mm/BSM(alone)/BSM + in ''lesion-by-lesion'' reading was 89.4 %/98.9 %/98.3 %/ 99.5 %; 69.1 %/96.9 %/72 %/92.1 % and 83.8 %/98.4 %/92.1 %/98.3 %, respectively. The use of BSM+ resulted in a change of response classification in 9.8 % patients (n = 6) from SD to PD. BSM reading is more accurate for monitoring myeloma compared to axial scans whereas BSM+ yields similar results with 1-mm reading (gold standard) but by significantly reduced reading time. (orig.)

  9. Thin-section CT of lung without ECG gating: 64-detector row CT can markedly reduce cardiac motion artifact which can simulate lung lesions

    International Nuclear Information System (INIS)

    Yanagawa, Masahiro; Tomiyama, Noriyuki; Sumikawa, Hiromitsu; Inoue, Atsuo; Daimon, Tadahisa; Honda, Osamu; Mihara, Naoki; Johkoh, Takeshi; Nakamura, Hironobu

    2009-01-01

    Purpose: Motion artifacts, which can mimic thickened bronchial wall and the cystic appearance of bronchiectasis, constitute a potential pitfall in the diagnosis of interstitial or bronchial disease. Therefore, purpose of our study was to evaluate whether 64-detector row CT (64-MDCT) enables a reduction in respiratory or cardiac motion artifacts in the lung area on thin-section CT without ECG gating, and to examine the correlation between cardiac motion artifact and heart rate. Materials and methods: Thirty-two patients with suspected diffuse lung disease, who underwent both 8- and 64-MDCT (gantry rotation time, 0.5 and 0.4 s, respectively), were included. The heart rates of an additional 155 patients were measured (range, 48-126 beats per minute; mean, 76 beats per minute) immediately prior to 64-MDCT, and compared to the degree of cardiac motion artifact. Two independent observers evaluated the following artifacts on a monitor without the knowledge of relevant clinical information: (1) artifacts on 8- and 64-MDCT images with 1.25-mm thickness and those on 64-MDCT images with 0.625-mm thickness in 32 patients; and (2) artifacts on 64-MDCT images with 0.625-mm thickness in 155 patients. Results: Interobserver agreement was good in evaluating artifacts on 8-MDCT images with 1.25-mm thickness (weighted Kappa test, κ = 0.61-0.71), and fair or poor in the other evaluations (κ < 0.31). Two observers stated that cardiac motion artifacts were more significant on 8-MDCT than on 64-MDCT in all 32 patients. Statistically significant differences were found at various checkpoints only in comparing artifacts between 8- and 64-MDCT for 1.25-mm thickness (Wilcoxon's signed-rank test, p < 0.0017). Cardiac motion artifacts on 64-MDCT had no significant correlation with heart rate (Spearman's correlation coefficient by rank test). Conclusion: The high temporal resolution of 64-MDCT appears to reduce cardiac motion artifact that can affect thin-section scans of the lung parenchyma

  10. Thin-section CT of lung without ECG gating: 64-detector row CT can markedly reduce cardiac motion artifact which can simulate lung lesions

    Energy Technology Data Exchange (ETDEWEB)

    Yanagawa, Masahiro [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)], E-mail: m-yanagawa@radiol.med.osaka-u.ac.jp; Tomiyama, Noriyuki; Sumikawa, Hiromitsu; Inoue, Atsuo [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Daimon, Tadahisa [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Medicine, Division of Pulmonary Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi 329-0498 (Japan); Honda, Osamu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Mihara, Naoki [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Radiology, Osaka Advanced Medical Imaging Center, 5-20-1 Momoyamadai, Suita-city, Osaka 565-0854 (Japan); Johkoh, Takeshi [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Medical Physics, Osaka University Graduate School of Medicine, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Nakamura, Hironobu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)

    2009-01-15

    Purpose: Motion artifacts, which can mimic thickened bronchial wall and the cystic appearance of bronchiectasis, constitute a potential pitfall in the diagnosis of interstitial or bronchial disease. Therefore, purpose of our study was to evaluate whether 64-detector row CT (64-MDCT) enables a reduction in respiratory or cardiac motion artifacts in the lung area on thin-section CT without ECG gating, and to examine the correlation between cardiac motion artifact and heart rate. Materials and methods: Thirty-two patients with suspected diffuse lung disease, who underwent both 8- and 64-MDCT (gantry rotation time, 0.5 and 0.4 s, respectively), were included. The heart rates of an additional 155 patients were measured (range, 48-126 beats per minute; mean, 76 beats per minute) immediately prior to 64-MDCT, and compared to the degree of cardiac motion artifact. Two independent observers evaluated the following artifacts on a monitor without the knowledge of relevant clinical information: (1) artifacts on 8- and 64-MDCT images with 1.25-mm thickness and those on 64-MDCT images with 0.625-mm thickness in 32 patients; and (2) artifacts on 64-MDCT images with 0.625-mm thickness in 155 patients. Results: Interobserver agreement was good in evaluating artifacts on 8-MDCT images with 1.25-mm thickness (weighted Kappa test, {kappa} = 0.61-0.71), and fair or poor in the other evaluations ({kappa} < 0.31). Two observers stated that cardiac motion artifacts were more significant on 8-MDCT than on 64-MDCT in all 32 patients. Statistically significant differences were found at various checkpoints only in comparing artifacts between 8- and 64-MDCT for 1.25-mm thickness (Wilcoxon's signed-rank test, p < 0.0017). Cardiac motion artifacts on 64-MDCT had no significant correlation with heart rate (Spearman's correlation coefficient by rank test). Conclusion: The high temporal resolution of 64-MDCT appears to reduce cardiac motion artifact that can affect thin-section scans of

  11. Interest of pelvimetry by multi detectors computed tomography (M.D.C.T.) 40 pins, reduction of the delivered dose

    International Nuclear Information System (INIS)

    Thibaut, C.; Marie-Anne, O.; Douws, C.; Grenier, N.; Chateil, J.F.

    2006-01-01

    This new procedure has allowed to improve the quality of measurement accuracy, annuls the difficulties of realizations of the conventional pictures and reduces in a considerable way the dose delivered to the patient and to the baby. (N.C.)

  12. Dose assessment of head CT examination by volume scanning with 320-area-detector

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Kobayashi, Masanao

    2009-01-01

    CT with the 320-area-detector (320-ADCT), first presented in 2007, still requires further basic studies, particularly in the field of dose assessment, as the CT has been widely spread in clinic due to its many advantages compared with the usual spiral CT. In this paper, the assessment in the title was thereby done in human phantom and a patient with suspicious acute cerebral infarction under different scanning modes (non-spiral, spiral and volume) for their comparison. Machines for 320-ADCT, and non-spiral and spiral CT were Toshiba Aquilion ONE, and Aquilion 64-MD, respectively. Scanning of the phantom and patient was individually conducted under similar conditions of tube voltage/ current, rotation time and length with the same field of view with defined nominal slice thicknesses. Alderson human body phantom in which 240 thermoluminescent dosimeters were indwelled, was used; doses were read by the thermoluminescence dosimeter (TLD) reader model 3000 (Kyokko Co.) after scanning; and effective doses were calculated with reference to ICRP publ. 102/103 equations for patient's head to be 4.2 (64-MDCT) and 6.6 (320-ADCT) mSv, which were respectively 6.4 and 5.4 mSv when estimated using the conversion coefficient and DLP (dose length product) in the texts. It was suggested that the exposure dose at the volume scanning by 320-ADCT can be reduced in the routine examination, and in the exact diagnosis, possibly increases. These doses can be reduced further by optimization of scanning conditions by additional basic investigations. (K.T.)

  13. High resolution CT in cystic fibrosis--the contribution of expiratory scans

    International Nuclear Information System (INIS)

    Dorloechter, Ludger; Nes, Harald; Fluge, Gjermund; Rosendahl, Karen

    2003-01-01

    Introduction: The use of high-resolution computed tomography (HRCT) is well accepted as an accurate method for evaluation of lung parenchyma in cystic fibrosis (CF). Several scoring methods exist and, in common, all are based on HRCT findings during inspiration alone. Objective: To examine whether expiratory HRCT scans could add information about the degree of mosaic perfusion in patients with CF. Methods and patients: Pulmonary HRCT was performed in 17 CF patients (median age of 12 years) with 1-mm thin sections and 10-mm intervals during inspiration, followed by 1-mm thin sections with 20-mm intervals during expiration. HRCT was scored by using a modified Bhalla method. Results: The mean HRCT score was 8.2. Out of 17 patients, 11 (65%) demonstrated a pathological mosaic perfusion in expiration, while only three patients showed mosaic perfusion in inspiration. The degree of expiratory mosaic perfusion was graded as severe in nine patients and moderate in two patients. There was a significant correlation between our modified HRCT score and lung function, as measured by forced expiratory volume in 1 s (FEV1% predicted, P<0.01). Conclusion: Mosaic perfusion in expiration was a common pathological HRCT finding in our study group. The clinical significance of this finding needs further evaluation

  14. MDCT abnormalities of small- and medium-sized bronchus in active tuberculosis: a new angle on an old disease

    International Nuclear Information System (INIS)

    Oh, Jin Kyoung; Ahn, Myeong Im; Jung, Jung Im; Han, Dae Hee; Kim, Young Kyoon; Oh, Eun-Jee; Park, Yeon-Joon

    2011-01-01

    Background: The incidence and findings of tuberculous invasion of the peripheral bronchus have not been fully investigated with MDCT. Purpose: To evaluate the prevalence and findings of MDCT abnormalities of small- and medium-sized bronchus (SMB) in active pulmonary tuberculosis (TB). Material and Methods: Using multiplanar reformation, 35 consecutive MDCT scans (follow-up exams available in 14 patients with a mean interval of 8.1 months) were assessed for following abnormalities of SMB: bronchial impaction (BI), wall thickening, dilatation, peribronchial cuff of soft tissue, and bronchocavitary fistula. It was also assessed whether tree-in-buds (TIB) have a tendency to distribute in the territories of diseased SMB, and whether SMB abnormalities are present in patients with relatively mild disease. Results: SMB abnormalities were observed in 23 (65.7%) patients with active TB. The most frequent finding was wall thickening (n=18, 51.4%), followed by BI (n=13, 37.1%; zigzag-shaped in four), dilatation (n =11, 31.4%), amputated appearance of air column (n=11, 31.4%), peribronchial cuff of soft tissue (n=10, 28.6%), and bronchocavitary fistula (n=8, 22.9%). TIB (n=29; absent in two patients with SMB) was mainly within (n=14) or close to (n=4) the territory of diseased SMB. Follow-up CT frequently showed improvement of wall thickening (11/12) and persistence of bronchial dilatation (11/13). SMB abnormality was present in all of six patients with mild disease. Conclusion: MDCT shows that tuberculous invasion of the peripheral bronchus may be more frequent than previously thought, of which findings include wall thickening, BI, dilatation, amputated appearance of air column, peribronchial cuff of soft tissue and bronchocavitary fistula

  15. MDCT abnormalities of small- and medium-sized bronchus in active tuberculosis: a new angle on an old disease

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jin Kyoung; Ahn, Myeong Im; Jung, Jung Im; Han, Dae Hee (Dept. of Radiology, Seoul St Mary' s Hospital, The Catholic Univ. of Korea, Seoul (Korea, Republic of)), email: lepolder@gmail.com; Kim, Young Kyoon (Dept. of Internal Medicine, Seoul St Mary' s Hospital, The Catholic Univ. of Korea, Seoul (Korea, Republic of)); Oh, Eun-Jee; Park, Yeon-Joon (Dept. of Laboratory Medicine, Seoul St Mary' s Hospital, The Catholic Univ. of Korea, Seoul (Korea, Republic of))

    2011-02-15

    Background: The incidence and findings of tuberculous invasion of the peripheral bronchus have not been fully investigated with MDCT. Purpose: To evaluate the prevalence and findings of MDCT abnormalities of small- and medium-sized bronchus (SMB) in active pulmonary tuberculosis (TB). Material and Methods: Using multiplanar reformation, 35 consecutive MDCT scans (follow-up exams available in 14 patients with a mean interval of 8.1 months) were assessed for following abnormalities of SMB: bronchial impaction (BI), wall thickening, dilatation, peribronchial cuff of soft tissue, and bronchocavitary fistula. It was also assessed whether tree-in-buds (TIB) have a tendency to distribute in the territories of diseased SMB, and whether SMB abnormalities are present in patients with relatively mild disease. Results: SMB abnormalities were observed in 23 (65.7%) patients with active TB. The most frequent finding was wall thickening (n=18, 51.4%), followed by BI (n=13, 37.1%; zigzag-shaped in four), dilatation (n =11, 31.4%), amputated appearance of air column (n=11, 31.4%), peribronchial cuff of soft tissue (n=10, 28.6%), and bronchocavitary fistula (n=8, 22.9%). TIB (n=29; absent in two patients with SMB) was mainly within (n=14) or close to (n=4) the territory of diseased SMB. Follow-up CT frequently showed improvement of wall thickening (11/12) and persistence of bronchial dilatation (11/13). SMB abnormality was present in all of six patients with mild disease. Conclusion: MDCT shows that tuberculous invasion of the peripheral bronchus may be more frequent than previously thought, of which findings include wall thickening, BI, dilatation, amputated appearance of air column, peribronchial cuff of soft tissue and bronchocavitary fistula

  16. Volume-monitored chest CT: a simplified method for obtaining motion-free images near full inspiratory and end expiratory lung volumes

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Kathryn S. [The Ohio State University College of Medicine, Columbus, OH (United States); Long, Frederick R. [Nationwide Children' s Hospital, The Children' s Radiological Institute, Columbus, OH (United States); Flucke, Robert L. [Nationwide Children' s Hospital, Department of Pulmonary Medicine, Columbus, OH (United States); Castile, Robert G. [The Research Institute at Nationwide Children' s Hospital, Center for Perinatal Research, Columbus, OH (United States)

    2010-10-15

    Lung inflation and respiratory motion during chest CT affect diagnostic accuracy and reproducibility. To describe a simple volume-monitored (VM) method for performing reproducible, motion-free full inspiratory and end expiratory chest CT examinations in children. Fifty-two children with cystic fibrosis (mean age 8.8 {+-} 2.2 years) underwent pulmonary function tests and inspiratory and expiratory VM-CT scans (1.25-mm slices, 80-120 kVp, 16-40 mAs) according to an IRB-approved protocol. The VM-CT technique utilizes instruction from a respiratory therapist, a portable spirometer and real-time documentation of lung volume on a computer. CT image quality was evaluated for achievement of targeted lung-volume levels and for respiratory motion. Children achieved 95% of vital capacity during full inspiratory imaging. For end expiratory scans, 92% were at or below the child's end expiratory level. Two expiratory exams were judged to be at suboptimal volumes. Two inspiratory (4%) and three expiratory (6%) exams showed respiratory motion. Overall, 94% of scans were performed at optimal volumes without respiratory motion. The VM-CT technique is a simple, feasible method in children as young as 4 years to achieve reproducible high-quality full inspiratory and end expiratory lung CT images. (orig.)

  17. Abdominal Hernias, Giant Colon Diverticulum, GIST, Intestinal Pneumatosis, Colon Ischemia, Cold Intussusception, Gallstone Ileus, and Foreign Bodies: Our Experience and Literature Review of Incidental Gastrointestinal MDCT Findings

    Directory of Open Access Journals (Sweden)

    G. Di Grezia

    2017-01-01

    Full Text Available Incidental gastrointestinal findings are commonly detected on MDCT exams performed for various medical indications. This review describes the radiological MDCT spectrum of appearances already present in the past literature and in today’s experience of several gastrointestinal acute conditions such as abdominal hernia, giant colon diverticulum, GIST, intestinal pneumatosis, colon ischemia, cold intussusception, gallstone ileus, and foreign bodies which can require medical and surgical intervention or clinical follow-up. The clinical presentation of this illness is frequently nonspecific: abdominal pain, distension, nausea, fever, rectal bleeding, vomiting, constipation, or a palpable mass, depending on the disease. A proper differential diagnosis is essential in the assessment of treatment and in this case MDCT exam plays a central rule. We wish that this article will familiarize the radiologist in the diagnosis of this kind of incidental MDCT findings for better orientation of the therapy.

  18. Potential benefit of a simultaneous, side-by-side display of contrast MDCT and echocardiography over routine sequential imaging for assessment of adult congenital heart disease: A preliminary study.

    Science.gov (United States)

    Oe, Hiroki; Watanabe, Nobuhisa; Miyoshi, Toru; Osawa, Kazuhiro; Akagi, Teiji; Kanazawa, Susumu; Ito, Hiroshi

    2018-06-18

    Management of adult congenital heart disease (ACHD) patients requires understanding of its complex morphology and functional features. An innovative imaging technique has been developed to display a virtual multi-planar reconstruction obtained from contrast-enhanced multidetector-computed tomography (MDCT) corresponding to the same cross-sectional image from transthoracic echocardiography (TTE). The aim of this study is to assess the usefulness of this imaging technology in ACHD patients. This study consisted of 46 consecutive patients (30 women; mean age, 52±18 years old) with ACHD who had undergone contrast MDCT. All patients underwent TTE within a week of MDCT. An experienced sonographer who did not know the results of MDCT conducted a diagnosis using TTE and, then, using the new imaging technology. We studied whether this imaging technology provided additional or unexpected findings or makes more accurate diagnosis. In this imaging technology, MDCT cross-section provides higher-resolution image to the deep compared to corresponding TTE image. Depending on the MDCT section which can be arbitrarily set under the echo guide, we can diagnose unexpected or incremental lesions or more accurately assess the severity of the lesion in 27 patients (59%) compared to TTE study alone. This imaging technology was useful in the following situations: CONCLUSIONS: This integrated imaging technology provides incremental role over TTE in complex anatomy, and allows functional information in ACHD patients. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  19. Assessment and diagnosis of acute bowel ischemia with multidetector computed tomography (MDCT)

    International Nuclear Information System (INIS)

    Sojka, B.; Gieszczyk-Paraniak, B.; Gibinska, J.; Konopka, M.

    2008-01-01

    Acute bowel ischemia (ABT) is a life-threatening condition which most often effects elderly patients. It requires an intensive treatment and quick diagnosis. Unfortunately ABI manifested not only by specific but also various nonspecific clinical or laboratory finding. The radiological symptoms of the bowel ischemia are also differentiated and often nonspecific while the specific findings are rather uncommon.That is why the knowledge of the bowel ischemia pathogenesis and possible CT findings is so important for the correct diagnosis. The our paper, we present the radiological findings of the acute bowel ischemia based on the analysis of the patients' abdominal -CT examination. The purpose of our study is to MDCT in patients with acute bowel ischemia. The material of this study consists of four computer tomography examinations - three of those an angio-CT and one abdominal - in patients with acute abdomen symptoms. The result revealed the mesenteric thrombosis in two cases, and mesenteric artery stenosis in one case. In one case, the thrombus was present in the abdominal aorta. In conclusion, we claim that the MDCT should be the modality of choice for the diagnosis of the acute bowel ischemia. (author)

  20. Radiation dosimetry and its influencing factors for the multi-detector/slice spiral CT

    International Nuclear Information System (INIS)

    Bai Mei; Zheng Junzheng

    2008-01-01

    The Multi-Detector/Slice Spiral Computed Tomography (MDCT/MSCT)reflects the new progress in equipment and technology for radiology. Its popularized application demonstrates its advantages for clinical diagnosis. With the continuous development and growing uses of the MDCT/MSCT, the medical exposure of the patients and public has also been increasing. Therefore, assessment of the radiation dose and radiation risk from X-CT has become an increasingly important concern that should be addressed. Thus, this paper summarizes the main characteristics of the MDCT/MSCT emphasizing particularly on the radiation dosimetry, and reviews the expressions and measures of radiation dose in the MDCT/MSCT. In addition, main factors that influence radiation dose from the MDCT/MSCT are also discussed. A proper grasp of its radiation dosimetry and assessment method can significantly help radiologists, health physicists, medical physicists, X-CT engineers and manufacturers improve the management of radiation dose while optimizing the image quality in the MDCT/MSCT. (authors)

  1. Regional specific mean expiratory gas flow from Slmsub(Kr) equilibrium inhalation data

    International Nuclear Information System (INIS)

    Hamilton, D.; Causer, D.A.; McIntosh, J.A.; Godfrey, K.R.

    1985-01-01

    A new method of analysing the data available from routine sup(81m) Kr equilibrium inhalation investigations has been developed. The data for analysis are acquired from a gamma camera in the form of a sequential series of images from which multiple breath activity-time curves are generated for eight regions in the lung. The method is based on a description of the behaviour of the radioactive gas in the lung using a mathematical model. Values of specific mean expiratory gas flow, that is mean expiratory gas flow per unit lung volume, are calculated from the application of the model to the expiratory phase only only of a single breath activity-time curve which is generated from the multiple breath activity-time curve using post-acquisition gating. This method overcomes the problem of non-uniform inspiratory concentration of tracer gas experienced in previously reported techniques of analysing inhalation data obtained using poorly soluble radioactive gases. The model is shown, in simulation studies, to be an adequate description of the behaviour of radioactive gas in the lung and the analysis technique is shown, in clinical studies, to be both reproducible and sensitive to disease state. (orig.)

  2. Abdominal wall reconstruction for large incisional hernia restores expiratory lung function

    DEFF Research Database (Denmark)

    Jensen, Kristian K; Backer, Vibeke; Jorgensen, Lars N

    2017-01-01

    BACKGROUND: Respiratory complications secondary to intermittent intra-abdominal hypertension and/or atelectasis are common after abdominal wall reconstruction for large incisional hernias. It is unknown if the respiratory function of this patient group is affected long term or impairs activities...... of daily living. We hypothesized that abdominal wall reconstruction for large incisional hernia would not lead to improved, long-term pulmonary function or respiratory quality of life. METHODS: Eighteen patients undergoing open abdominal wall reconstruction with mesh for a large incisional hernia...... (horizontal fascial defect width >10 cm) were compared with 18 patients with an intact abdominal wall who underwent colorectal resection. Patients were examined pre- and 1-year postoperatively. Examined measures included forced vital capacity, forced expiratory volume in first second, peak expiratory flow...

  3. Renal cell carcinoma metastases to the pancreas - Value of arterial phase imaging at MDCT

    International Nuclear Information System (INIS)

    Corwin, Michael T.; Lamba, Ramit; McGahan, John P.; Wilson, Machelle

    2013-01-01

    Background: The pancreas is an increasingly recognized site of renal cell carcinoma metastases. It is important to determine the optimal MDCT protocol to best detect RCC metastases to the pancreas. Purpose: To compare the rate of detection of renal cell carcinoma metastases to the pancreas between arterial and portal venous phase MDCT. Material and Methods: A retrospective review of CTs of the abdomen yielded six patients with metastatic RCC to the pancreas. Five of six patients had pathologically proven clear cell RCC. Two blinded reviewers independently reported the number of pancreatic lesions seen in arterial and venous phases. Each lesion was graded as definite or possible. The number of lesions was determined by consensus review of both phases. Attenuation values were obtained for metastatic lesions and adjacent normal pancreas in both phases. Results: There were a total of 24 metastatic lesions to the pancreas. Reviewer 1 identified 20/24 (83.3%) lesions on the arterial phase images and 13/24 (54.2%) lesions on the venous phase. Seventeen of 20 (85.0%) arterial lesions were deemed definite and 9/13 (69.2%) venous lesions were definite. Reviewer 2 identified 19/24 (79.2%) lesions on the arterial phase and 14/24 (58.3%) on the venous phase. Seventeen of 19 (89.5%) arterial lesions were definite and 7/14 (50%) venous lesions were definite. Mean attenuation differential between lesion and pancreas was 114 HU and 39 HU for arterial and venous phases, respectively (P<0.0001). Conclusion: Detection of RCC metastases to the pancreas at MDCT is improved using arterial phase imaging compared to portal venous phase imaging

  4. Reduced-dose C-arm computed tomography applications at a pediatric institution

    Energy Technology Data Exchange (ETDEWEB)

    Acord, Michael; Shellikeri, Sphoorti; Vatsky, Seth; Srinivasan, Abhay; Krishnamurthy, Ganesh; Keller, Marc S.; Cahill, Anne Marie [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2017-12-15

    Reduced-dose C-arm computed tomography (CT) uses flat-panel detectors to acquire real-time 3-D images in the interventional radiology suite to assist with anatomical localization and procedure planning. To describe dose-reduction techniques for C-arm CT at a pediatric institution and to provide guidance for implementation. We conducted a 5-year retrospective study on procedures using an institution-specific reduced-dose protocol: 5 or 8 s Dyna Rotation, 248/396 projection images/acquisition and 0.1-0.17 μGy/projection dose at the detector with 0.3/0.6/0.9-mm copper (Cu) filtration. We categorized cases by procedure type and average patient age and calculated C-arm CT and total dose area product (DAP). Two hundred twenty-two C-arm CT-guided procedures were performed with a dose-reduction protocol. The most common procedures were temporomandibular and sacroiliac joint injections (48.6%) and sclerotherapy (34.2%). C-arm CT was utilized in cases of difficult percutaneous access in less common applications such as cecostomy and gastrostomy placement, foreign body retrieval and thoracentesis. C-arm CT accounted for between 9.9% and 80.7% of the total procedural DAP. Dose-reducing techniques can preserve image quality for intervention while reducing radiation exposure to the child. This technology has multiple applications within pediatric interventional radiology and can be considered as an adjunctive imaging tool in a variety of procedures, particularly when percutaneous access is challenging despite routine fluoroscopic or ultrasound guidance. (orig.)

  5. Factors influencing peak expiratory flow in teenage boys | van ...

    African Journals Online (AJOL)

    Background. Peak expiratory flow (PEF) is a useful measure of pulmonary health status and is frequently utilised in asthm, management. Reduction in PEF is usually indicative of onset (of asthma symptoms. However, use can be made of PEF values only if normal values are known. The definition of normal range is always ...

  6. Development of a Radiation Dose Reporting Software for X-ray Computed Tomography (CT)

    Science.gov (United States)

    Ding, Aiping

    X-ray computed tomography (CT) has experienced tremendous technological advances in recent years and has established itself as one of the most popular diagnostic imaging tools. While CT imaging clearly plays an invaluable role in modern medicine, its rapid adoption has resulted in a dramatic increase in the average medical radiation exposure to the worldwide and United States populations. Existing software tools for CT dose estimation and reporting are mostly based on patient phantoms that contain overly simplified anatomies insufficient in meeting the current and future needs. This dissertation describes the development of an easy-to-use software platform, “VirtualDose”, as a service to estimate and report the organ dose and effective dose values for patients undergoing the CT examinations. “VirtualDose” incorporates advanced models for the adult male and female, pregnant women, and children. To cover a large portion of the ignored obese patients that frequents the radiology clinics, a new set of obese male and female phantoms are also developed and applied to study the effects of the fat tissues on the CT radiation dose. Multi-detector CT scanners (MDCT) and clinical protocols, as well as the most recent effective dose algorithms from the International Commission on Radiological Protection (ICRP) Publication 103 are adopted in “VirtualDose” to keep pace with the MDCT development and regulatory requirements. A new MDCT scanner model with both body and head bowtie filter is developed to cover both the head and body scanning modes. This model was validated through the clinical measurements. A comprehensive slice-by-slice database is established by deriving the data from a larger number of single axial scans simulated on the patient phantoms using different CT bowtie filters, beam thicknesses, and different tube voltages in the Monte Carlo N-Particle Extended (MCNPX) code. When compared to the existing CT dose software packages, organ dose data in this

  7. MDCT after balloon kyphoplasty: analysis of vertebral body architecture one year after treatment of osteoporotic fractures

    International Nuclear Information System (INIS)

    Roehrl, B.; Dueber, C.; Sadick, M.; Brocker, K.; Voggenreiter, G.; Obertacke, U.; Brade, J.

    2006-01-01

    Purpose: to evaluate the value of MDCT in the monitoring of vertebral body architecture after balloon kyphoplasty and observe morphological changes of the vertebral body. Material and methods: during a period of 26 months, 66 osteoporotic fractures of the vertebral bodies were treated with percutanous balloon kyphoplasty. The height of the vertebral body, width of spinal space, sagittal indices, kyphosis und COBB angle, and cement leakage were evaluated by computed tomography before and after treatment and in a long-term follow up. Statistical analysis was performed by calculating quantitative constant parameters of descriptive key data. In addition, parametric and distribution-free procedures were performed for all questions. Results: after kyphoplasty, the treated vertebral bodies showed a significant gain in the height of the leading edge (0.15 cm; p < 0.0001) and in the central part of the vertebral body (0.17 cm; p < 0.0001). The height of the trailing edge did not change significantly. A corresponding gain in the sagittal index was found. The index remained stable during follow-up. Treated vertebral bodies as well as untreated references showed a comparable loss of height over the period of one year. The shape of the vertebral bodies remained stable. In comparison to these findings, treated vertebral bodies showed a reduced loss of height. A significant change in kyphosis und the COBB angle was noted. In total, pallacos leakage was detected in 71% of cases. Conclusion: MDCT is an accurate method for evaluating vertebral body architecture after treatment with balloon kyphoplasty. (orig.)

  8. Influence of Contrast Media on Bone Mineral Density (BMD) Measurements from Routine Contrast-Enhanced MDCT Datasets using a Phantom-less BMD Measurement Tool.

    Science.gov (United States)

    Toelly, Andrea; Bardach, Constanze; Weber, Michael; Gong, Rui; Lai, Yanbo; Wang, Pei; Guo, Yulin; Kirschke, Jan; Baum, Thomas; Gruber, Michael

    2017-06-01

    Aim  To evaluate the differences in phantom-less bone mineral density (BMD) measurements in contrast-enhanced routine MDCT scans at different contrast phases, and to develop an algorithm for calculating a reliable BMD value. Materials and Methods  112 postmenopausal women from the age of 40 to 77 years (mean age: 57.31 years; SD 9.61) who underwent a clinically indicated MDCT scan, consisting of an unenhanced, an arterial, and a venous phase, were included. A retrospective analysis of the BMD values of the Th12 to L4 vertebrae in each phase was performed using a commercially available phantom-less measurement tool. Results  The mean BMD value in the unenhanced MDCT scans was 79.76 mg/cm³ (SD 31.20), in the arterial phase it was 85.09 mg/cm³ (SD 31.61), and in the venous phase it was 86.18 mg/cm³ (SD 31.30). A significant difference (p Influence of Contrast Media on Bone Mineral Density (BMD) Measurements from Routine Contrast-Enhanced MDCT Datasets using a Phantom-less BMD Measurement Tool. Fortschr Röntgenstr 2017; 189: 537 - 543. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Reducing dose calculation time for accurate iterative IMRT planning

    International Nuclear Information System (INIS)

    Siebers, Jeffrey V.; Lauterbach, Marc; Tong, Shidong; Wu Qiuwen; Mohan, Radhe

    2002-01-01

    A time-consuming component of IMRT optimization is the dose computation required in each iteration for the evaluation of the objective function. Accurate superposition/convolution (SC) and Monte Carlo (MC) dose calculations are currently considered too time-consuming for iterative IMRT dose calculation. Thus, fast, but less accurate algorithms such as pencil beam (PB) algorithms are typically used in most current IMRT systems. This paper describes two hybrid methods that utilize the speed of fast PB algorithms yet achieve the accuracy of optimizing based upon SC algorithms via the application of dose correction matrices. In one method, the ratio method, an infrequently computed voxel-by-voxel dose ratio matrix (R=D SC /D PB ) is applied for each beam to the dose distributions calculated with the PB method during the optimization. That is, D PB xR is used for the dose calculation during the optimization. The optimization proceeds until both the IMRT beam intensities and the dose correction ratio matrix converge. In the second method, the correction method, a periodically computed voxel-by-voxel correction matrix for each beam, defined to be the difference between the SC and PB dose computations, is used to correct PB dose distributions. To validate the methods, IMRT treatment plans developed with the hybrid methods are compared with those obtained when the SC algorithm is used for all optimization iterations and with those obtained when PB-based optimization is followed by SC-based optimization. In the 12 patient cases studied, no clinically significant differences exist in the final treatment plans developed with each of the dose computation methodologies. However, the number of time-consuming SC iterations is reduced from 6-32 for pure SC optimization to four or less for the ratio matrix method and five or less for the correction method. Because the PB algorithm is faster at computing dose, this reduces the inverse planning optimization time for our implementation

  10. Preoperative evaluation of colorectal liver metastases: comparison between gadoxetic acid-enhanced 3.0-T MRI and contrast-enhanced MDCT with histopathological correlation

    Energy Technology Data Exchange (ETDEWEB)

    Scharitzer, M.; Ba-Ssalamah, A.; Ringl, H.; Koelblinger, C.; Weber, M. [Medical University of Vienna, Department of Radiology, Vienna (Austria); Gruenberger, T. [Medical University of Vienna, Department of Surgery, Vienna (Austria); Schima, W. [Department of Radiology, KH Goettlicher Heiland, KH der Barmherzigen Schwestern and St Josef-Krankenhaus, Vienna (Austria)

    2013-08-15

    The aim of this prospective study was to compare the diagnostic performance of 64-row MDCT and gadoxetic-acid-enhanced MRI at 3.0 T in patients with colorectal liver metastases in correlation with histopathological findings. Lesions detected at MDCT and MRI were interpreted by three blinded readers and compared with histopathological workup as the term of reference. Two subgroups of lesions were additionally evaluated: (1) metastases smaller than 10 mm and (2) lesions in patients with and without steatosis of the liver, assessed histopathologically. Surgery and histopathological workup revealed 81 colorectal liver metastases in 35 patients and diffuse metastatic involvement in 3 patients. In a lesion-by-lesion analysis, significant sensitivity differences could only be found for reader 1 (P = 0.035) and reader 3 (P = 0.003). For segment-based evaluation, MRI was more sensitive only for reader 3 (P = 0.012). The number of false-positive results ranged from 3 to 12 for MDCT and 8 to 11 for MRI evaluation. In the group of small lesions, the sensitivity differed significantly between both methods (P = 0.003). In patients with hepatic steatosis, MRI showed a trend toward better performance than MDCT, but without statistical performance. The 3.0-T MRI with liver-specific contrast agents is the preferred investigation in the preoperative setting, especially for the assessment of small colorectal liver metastases. (orig.)

  11. Reducing dose to the lungs through loosing target dose homogeneity requirement for radiotherapy of non small cell lung cancer.

    Science.gov (United States)

    Miao, Junjie; Yan, Hui; Tian, Yuan; Ma, Pan; Liu, Zhiqiang; Li, Minghui; Ren, Wenting; Chen, Jiayun; Zhang, Ye; Dai, Jianrong

    2017-11-01

    It is important to minimize lung dose during intensity-modulated radiation therapy (IMRT) of nonsmall cell lung cancer (NSCLC). In this study, an approach was proposed to reduce lung dose by relaxing the constraint of target dose homogeneity during treatment planning of IMRT. Ten NSCLC patients with lung tumor on the right side were selected. The total dose for planning target volume (PTV) was 60 Gy (2 Gy/fraction). For each patient, two IMRT plans with six beams were created in Pinnacle treatment planning system. The dose homogeneity of target was controlled by constraints on the maximum and uniform doses of target volume. One IMRT plan was made with homogeneous target dose (the resulting target dose was within 95%-107% of the prescribed dose), while another IMRT plan was made with inhomogeneous target dose (the resulting target dose was more than 95% of the prescribed dose). During plan optimization, the dose of cord and heart in two types of IMRT plans were kept nearly the same. The doses of lungs, PTV and organs at risk (OARs) between two types of IMRT plans were compared and analyzed quantitatively. For all patients, the lung dose was decreased in the IMRT plans with inhomogeneous target dose. On average, the mean dose, V5, V20, and V30 of lung were reduced by 1.4 Gy, 4.8%, 3.7%, and 1.7%, respectively, and the dose to normal tissue was also reduced. These reductions in DVH values were all statistically significant (P target dose could protect lungs better and may be considered as a choice for treating NSCLC. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  12. predicted peak expiratory flow in human and the clinical implication ...

    African Journals Online (AJOL)

    DR. AMINU

    predicted PEF varied widely across formulae and choice of a particular formula may alter guideline- base care. This work has therefore accepted a recently published population-base equation proposed as the reference standard for future asthma guidelines. Keywords: Peak expiratory flow, Asthma, Practice guidelines, ...

  13. Knowledge, attitude and practice of nurses toward peak expiratory ...

    African Journals Online (AJOL)

    Background: Peak expiratory flow meter (PEFM) is an easy to use, relatively cheap device that can be used for guiding management of bronchial asthma by the patients at home according to a preset plan by health care workers. Objective: The aim of the study is to reveal the extent of knowledge and perception of nurses ...

  14. Empirical description of bronchial and nonbronchial arteries with MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Yu Hong, E-mail: yuhong.2002@hotmail.co [Department of Imageology, Changzheng hospital, Second Military Medical University, Shanghai 200003 (China); Liu Shiyuan, E-mail: cjr.liushiyuan@vip.163.co [Department of Imageology, Changzheng hospital, Second Military Medical University, Shanghai 200003 (China); Li Huimin, E-mail: yuhongphd@163.co [Department of Imageology, Changzheng hospital, Second Military Medical University, Shanghai 200003 (China); Xiao Xiangsheng, E-mail: cjr.xxsh@vip.163.co [Department of Imageology, Changzheng hospital, Second Military Medical University, Shanghai 200003 (China); Dong Weihua, E-mail: dongweihua2000@163.co [Department of Imageology, Changzheng hospital, Second Military Medical University, Shanghai 200003 (China)

    2010-08-15

    Purpose: We aimed to retrospectively evaluate bronchial and nonbronchial systemic arteries using multi-detector row helical computed tomographic (MDCT) angiography in patients with pulmonary disorders. Materials and Methods: Thirty-nine patients (24 men, 15 women; mean age, 63.4 years; range, 20-82 years) with congenital and acquired pulmonary disorders of the bronchial and nonbronchial systemic arteries underwent multi-detector row helical computed tomographic angiography of the thorax using a 16-detector row scanner. Each of these patients had experienced an episode of hemoptysis. Computed tomographic angiogram data, which included maximum intensity projections, multiplanar reconstruction, and three-dimensional volume-rendered images, were used to retrospectively analyse the characteristics of the bronchial and nonbronchial systemic arteries. Results: We identified a total of 128 bronchial arteries (76 on the right side and 52 on the left) in 39 patients. We detected 42 nonbronchial systemic artery branches, including 19 internal mammary artery branches, 8 subclavian artery branches, 8 inferior phrenic artery branches, 5 intercostal artery branches, 1 thyrocervical trunk branch, and 1 celiac trunk branch. Thirty-five dilated and tortuous nonbronchial systemic arteries entered into the lung parenchyma and extended down to the lesions. Every case, except the one case of sequestration, was associated with pleural thickening where the vascular structures passed through the extrapleural fat. Conclusions: The variations in both the bronchial artery anatomy and the location and type of the nonbronchial arteries were great. Nonbronchial arteries may be a significant source of hemoptysis. MDCT angiography can be used to detect detailed anatomical information about the origins and courses of bronchial and nonbronchial systemic arteries and their pathophysiologic features.

  15. Clinical and prognostic significance of bone marrow abnormalities in the appendicular skeleton detected by low-dose whole-body multidetector computed tomography in patients with multiple myeloma

    International Nuclear Information System (INIS)

    Nishida, Y; Matsue, Y; Suehara, Y; Fukumoto, K; Fujisawa, M; Takeuchi, M; Ouchi, E; Matsue, K

    2015-01-01

    Clinical significance of medullary abnormalities in the appendicular skeleton (AS) detected by low-dose whole-body multidetector computed tomography (MDCT) in patients with multiple myeloma (MM) was investigated. A total of 172 patients with monoclonal gammopathy of undetermined significance (MGUS) (n=17), smoldering MM (n=47) and symptomatic MM (n=108) underwent low-dose MDCT. CT values (CTv) of medullary density of AS⩾0 Hounsfield unit (HU) was considered as abnormal. Percentage of medullary abnormalities and the mean CTv of AS in patients with MGUS, smoldering MM and symptomatic MM were 18, 55 and 62% and −44.5 , −20.3 and 11.2 HU, respectively (P<0.001 and P<0.001). Disease progression of MM was independently associated with high CTv on multivariate analysis. In symptomatic MM, the presence of abnormal medullary lesions was associated with increased incidence of high-risk cytogenetic abnormalities (34.4% vs 7.7% P=0.002) and extramedullary disease (10.4% vs 0% P=0.032). It was also an independent poor prognostic predictor (hazard ratio 3.546, P=0.04). This study showed that CTv of AS by MDCT is correlated with disease progression of MM, and the presence of abnormal medullary lesions is a predictor for poor survival

  16. Italian multicenter, prospective study to evaluate the negative predictive value of 16- and 64-slice MDCT imaging in patients scheduled for coronary angiography (NIMISCAD-non invasive multicenter Italian study for coronary artery disease)

    International Nuclear Information System (INIS)

    Marano, Riccardo; Cobelli, Francesco de; Maschio, Alessandro del; Becker, Christoph; Herzog, Christopher; Centonze, Maurizio; Morana, Giovanni; Gualdi, Gian Franco; Ligabue, Guido; Pontone, Gianluca; Catalano, Carlo; Chiappino, Dante; Midiri, Massimo; Simonetti, Giovanni; Marchisio, Filippo; Olivetti, Lucio; Fattori, Rossella; Bonomo, Lorenzo

    2009-01-01

    This was a prospective, multicenter study designed to evaluate the utility of MDCT in the diagnosis of coronary artery disease (CAD) in patients scheduled for elective coronary angiography (CA) using different MDCT systems from different manufacturers. Twenty national sites prospectively enrolled 367 patients between July 2004 and June 2006. Computed tomography (CT) was performed using a standardized/optimized scan protocol for each type of MDCT system (≥16 slices) and compared with quantitative CA performed within 2 weeks of MDCT. A total of 284 patients (81%) were studied by 16-slice MDCT systems, while 66 patients (19%) by 64-slice MDCT scanners. The primary analysis was on-site/off-site evaluation of the negative predictive value (NPV) on a per-patient basis. Secondary analyses included on-site evaluation on a per-artery and per-segment basis. On-site evaluation included 327 patients (CAD prevalence 58%). NPV, positive predictive value (PPV), sensitivity, specificity, and diagnostic accuracy (DA) were 0.91 (95% CI 0.85-0.95), 0.91 (95% CI 0.86-0.95), 0.94 (95% CI 0.89-0.97), 0.88 (95% CI 0.81-0.93), and 0.91 (95% CI 0.88-0.94), respectively. Off-site analysis included 295 patients (CAD prevalence 56%). NPV, PPV, sensitivity, specificity, and DA were 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), and 0.82 (95% CI 0.77-0.86), respectively. The results of this study demonstrate the utility of MDCT in excluding significant CAD even when conducted by centers with varying degrees of expertise and using different MDCT machines. (orig.)

  17. Patient-specific dose estimation for pediatric chest CT

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P. [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Department of Radiology, Duke Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Department of Radiology, Duke Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Physics, Duke University, Durham, North Carolina 27710 (United States); and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Department of Radiology, Duke Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Global Applied Science Laboratory, GE Healthcare, Waukesha, Wisconsin 53188 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Department of Radiology, Division of Pediatric Radiology, Duke University Medical Center, Durham North Carolina 27710 (United States)

    2008-12-15

    Current methods for organ and effective dose estimations in pediatric CT are largely patient generic. Physical phantoms and computer models have only been developed for standard/limited patient sizes at discrete ages (e.g., 0, 1, 5, 10, 15 years old) and do not reflect the variability of patient anatomy and body habitus within the same size/age group. In this investigation, full-body computer models of seven pediatric patients in the same size/protocol group (weight: 11.9-18.2 kg) were created based on the patients' actual multi-detector array CT (MDCT) data. Organs and structures in the scan coverage were individually segmented. Other organs and structures were created by morphing existing adult models (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. Organ and effective dose of these patients from a chest MDCT scan protocol (64 slice LightSpeed VCT scanner, 120 kVp, 70 or 75 mA, 0.4 s gantry rotation period, pitch of 1.375, 20 mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated to simulate radiation transport in the same CT system. The seven patients had normalized effective dose of 3.7-5.3 mSv/100 mAs (coefficient of variation: 10.8%). Normalized lung dose and heart dose were 10.4-12.6 mGy/100 mAs and 11.2-13.3 mGy/100 mAs, respectively. Organ dose variations across the patients were generally small for large organs in the scan coverage (<7%), but large for small organs in the scan coverage (9%-18%) and for partially or indirectly exposed organs (11%-77%). Normalized effective dose correlated weakly with body weight (correlation coefficient: r=-0.80). Normalized lung dose and heart dose correlated strongly with mid-chest equivalent diameter (lung: r=-0.99, heart: r=-0.93); these strong correlation relationships can be used to estimate patient-specific organ

  18. Arterial double-contrast dual-energy MDCT: in-vivo rabbit atherosclerosis with iodinated nanoparticles and gadolinium agents

    Science.gov (United States)

    Carmi, Raz; Kafri, Galit; Altman, Ami; Goshen, Liran; Planer, David; Sosna, Jacob

    2010-03-01

    An in-vivo feasibility study of potentially improved atherosclerosis CT imaging is presented. By administration of two different contrast agents to rabbits with induced atherosclerotic plaques we aim at identifying both soft plaque and vessel lumen simultaneously. Initial injection of iodinated nanoparticle (INP) contrast agent (N1177 - Nanoscan Imaging), two to four hours before scan, leads to its later accumulation in macrophage-rich soft plaque, while a second gadolinium contrast agent (Magnevist) injected immediately prior to the scan blends with the aortic blood. The distinction between the two agents in a single scan is achieved with a double-layer dual-energy MDCT (Philips Healthcare) following material separation analysis using the reconstructed images of the different x-ray spectra. A single contrast agent injection scan, where only INP was injected two hours prior to the scan, was compared to a double-contrast scan taken four hours after INP injection and immediately after gadolinium injection. On the single contrast agent scan we observed along the aorta walls, localized iodine accumulation which can point on INP uptake by atherosclerotic plaque. In the double-contrast scan the gadolinium contributes a clearer depiction of the vessel lumen in addition to the lasting INP presence. The material separation shows a good correlation to the pathologies inferred from the conventional CT images of the two different scans while performing only a single scan prevents miss-registration problems and reduces radiation dose. These results suggest that a double-contrast dual-energy CT may be used for advanced clinical diagnostic applications.

  19. 64-Slice multidetector row CT angiography of the abdomen: comparison of low versus high concentration iodinated contrast media in a porcine model

    Science.gov (United States)

    Holalkere, N-S; Matthes, K; Kalva, S P; Brugge, W R; Sahani, D V

    2011-01-01

    Objective In this study we aimed to assess the image quality and degree of vascular enhancement using low-concentration contrast media (LCCM) (300 mg I ml–1) and high-concentration contrast media (HCCM) (370 mg I ml–1) on 64-slice multidetector row CT (MDCT) abdominal CT angiography (CTA). In addition, we aimed to study the feasibility of using HCCM with a reduced total iodine dose. Methods CTA of the abdomen on a 64-slice MDCT was performed on 15 anaesthetised pigs. Study pigs were divided into three groups of five each based on the iodine concentration and dose received: Group A (LCCM; 300 mg I ml–1), Group B (HCCM; 370 mg I ml–1) and Group C HCCM with 20% less iodine dose. The total iodine injected was kept constant (600 mg kg–1) in Groups A and B. Qualitative and quantitative analyses were performed to study and compare each group for image quality, visibility of the branch order of the superior mesenteric artery (SMA), artefacts, degree of enhancement in the aorta and main stem arteries and uniformity of enhancement in the aorta. Groups were compared using the analysis of variance test. Results The image quality of 64-slice MDCT angiography was excellent with a mean score of 4.63 and confident visualisation of the third to fifth order branches of the SMA in all groups. Group B demonstrated superior vascular enhancement, as compared with Groups A and C (p≤0.05). Uniform aortic enhancement was achieved with the use of LCCM and HCCM with 20% less iodine dose. Conclusion 64-slice MDCT angiography of the abdomen was of excellent quality. HCCM improves contrast enhancement and overall CTA image quality and allows the iodine dose to be reduced. PMID:21081582

  20. Evaluation of multiple trauma victims with 16-row multidetector CT (MDCT): a time analysis

    International Nuclear Information System (INIS)

    Heyer, C.M.; Nicolas, V.

    2005-01-01

    Purpose: Description and time analysis of a 16-row MDCT protocol in the evaluation of multiple trauma patients considering transport, time of scanning, patient positioning, image reconstruction, and image interpretation. Materials and methods: Between May and December 2004, 60 multiple trauma patients underwent 16-row MDCT (Sensation, Siemens, Erlangen, Germany). The protocol included serial scanning of the head, spiral scanning of the cervical spine and contrast-enhanced spiral scanning of the thorax/abdomen with multiplanar reformations (MPR) of the thoracic/lumbar spine and the pelvis. All time intervals including transport, patient positioning, scanning, duration of MPR, total time in the examination room, and time to first and final image interpretation were prospectively evaluated. Furthermore, patient characteristics, trauma profiles, and mortality rates were recorded. Results: 46 male and 14 female patients (mean age 43.6 years) were enrolled in the study. Time analysis of 16-row MDCT revealed the following results (mean time standard deviation): Emergency room treatment and transport 19.2±6.7 min, patient positioning 16.5±6.5 min, scan duration 8.0±3.3 min, total time in examination room 24.5±7.2 min, image reconstruction including MPR 32.0±16.4 min, and time of first (16.4±4.7 min) and final image interpretation (82.5±30.4 min). Trauma profiles revealed thoracic injuries in 35/60 patients (58.3%), head injuries in 23/60 patients (38.3%), abdominal injuries in 15/60 patients (25.0%), injuries of the cervical (9/60 patients, 15.0%), thoracic (12/60 patients, 20.0%), and lumbar spine (19/60 patients, 31.7%), pelvic injuries in 13/60 patients (21.7%), and injuries of extremities in 39/60 patients (65.0%). The mortality rate was 21.7%. (orig.)

  1. Inter-scan reproducibility of coronary calcium measurement using Multi Detector-Row Computed Tomography (MDCT)

    International Nuclear Information System (INIS)

    Sabour, Siamak; Rutten, A.; Schouw, Y. T. van der; Atsma, F.; Grobbee, D. E.; Mali, W. P.; Bartelink, M. E. L.; Bots, M. L.; Prokop, M.

    2007-01-01

    Purpose. To assess inter-scan reproducibility of coronary calcium measurements obtained from Multi Detector-Row CT (MDCT) images and to evaluate whether this reproducibility is affected by different measurement protocols, slice thickness, cardiovascular risk factors and/or technical variables.Design. Cross-sectional study with repeated measurements. Materials and methods. The study population comprised 76 healthy women. Coronary calcium was assessed in these women twice in one session using 16-MDCT (Philips Mx 8000 IDT 16). Images were reconstructed with 1.5 mm slice thickness and 3.0 mm slice thickness. The 76 repeated scans were scored. The Agatston score, a volume measurement and a mass measurement were assessed. Reproducibility was determined by estimation of mean, absolute, relative difference, the weighted kappa value for agreement and the Intra-class correlation coefficient (ICCC).Results. Fifty-five participants (72.4%) had a coronary calcification of more than zero in Agatston (1.5 mm slice thickness). The reproducibility of coronary calcium measurements between scans in terms of ranking was excellent with Intra-class correlation coefficients of >0.98, and kappa values above 0.80. The absolute difference in calcium score between scans increased with increasing calcium levels, indicating that measurement error increases with increasing calcium levels. However, no relation was found between the mean difference in scores and calcium levels, indicating that the increase in measurement error is likely to result in random misclassification in calcium score. Reproducibility results were similar for 1.5 mm slices and for 3.0 mm slices, and equal for Agatston, volume and mass measurements.Conclusion. Inter-scan reproducibility of measurement of coronary calcium using images from MDCT is excellent, irrespective of slice thickness and type of calcium parameter

  2. Novel high dose rate lip brachytherapy technique to improve dose homogeneity and reduce toxicity by customized mold

    International Nuclear Information System (INIS)

    Feldman, Jon; Appelbaum, Limor; Sela, Mordechay; Voskoboinik, Ninel; Kadouri, Sarit; Weinberger, Jeffrey; Orion, Itzhak; Meirovitz, Amichay

    2014-01-01

    The purpose of this study is to describe a novel brachytherapy technique for lip Squamous Cell Carcinoma, utilizing a customized mold with embedded brachytherapy sleeves, which separates the lip from the mandible, and improves dose homogeneity. Seven patients with T2 lip cancer treated with a “sandwich” technique of High Dose Rate (HDR) brachytherapy to the lip, consisting of interstitial catheters and a customized mold with embedded catheters, were reviewed for dosimetry and outcome using 3D planning. Dosimetric comparison was made between the “sandwich” technique to “classic” – interstitial catheters only plan. We compared dose volume histograms for Clinical Tumor Volume (CTV), normal tissue “hot spots” and mandible dose. We are reporting according to the ICRU 58 and calculated the Conformal Index (COIN) to show the advantage of our technique. The seven patients (ages 36–81 years, male) had median follow-up of 47 months. Four patients received Brachytherapy and External Beam Radiation Therapy, 3 patients received brachytherapy alone. All achieved local control, with excellent esthetic and functional results. All patients are disease free. The Customized Mold Sandwich technique (CMS) reduced the high dose region receiving 150% (V150) by an average of 20% (range 1–47%), The low dose region (les then 90% of the prescribed dose) improved by 73% in average by using the CMS technique. The COIN value for the CMS was in average 0.92 as opposed to 0.88 for the interstitial catheter only. All differences (excluding the low dose region) were statistically significant. The CMS technique significantly reduces the high dose volume and increases treatment homogeneity. This may reduce the potential toxicity to the lip and adjacent mandible, and results in excellent tumor control, cosmetic and functionality

  3. Balancing Radiation and Contrast Media Dose in Single-Pass Abdominal Multidetector CT: Prospective Evaluation of Image Quality.

    Science.gov (United States)

    Camera, Luigi; Romano, Federica; Liccardo, Immacolata; Liuzzi, Raffaele; Imbriaco, Massimo; Mainenti, Pier Paolo; Pizzuti, Laura Micol; Segreto, Sabrina; Maurea, Simone; Brunetti, Arturo

    2015-11-01

    As both contrast and radiation dose affect the quality of CT images, a constant image quality in abdominal contrast-enhanced multidetector computed tomography (CE-MDCT) could be obtained balancing radiation and contrast media dose according to the age of the patients. Seventy-two (38 Men; 34 women; aged 20-83 years) patients underwent a single-pass abdominal CE-MDCT. Patients were divided into three different age groups: A (20-44 years); B (45-65 years); and C (>65 years). For each group, a different noise index (NI) and contrast media dose (370 mgI/mL) was selected as follows: A (NI, 15; 2.5 mL/kg), B (NI, 12.5; 2 mL/kg), and C (NI, 10; 1.5 mL/kg). Radiation exposure was reported as dose-length product (DLP) in mGy × cm. For quantitative analysis, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated for both the liver (L) and the abdominal aorta (A). Statistical analysis was performed with a one-way analysis of variance. Standard imaging criteria were used for qualitative analysis. Although peak hepatic enhancement was 152 ± 16, 128 ± 12, and 101 ± 14 Hounsfield units (P contrast media dose (mL) administered were 476 ± 147 and 155 ± 27 for group A, 926 ± 291 and 130 ± 16 for group B, and 1981 ± 451 and 106 ± 15 for group C, respectively (P contrast media dose administered to patients of different age. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  4. Evaluation of Peak Expiratory Flow Rates (PEFR) of Workers in a ...

    African Journals Online (AJOL)

    DATONYE ALASIA

    and knowledge of occupational health associated with the ... the respiratory system with significant. 5 ... Peak Expiratory Flow Rates (PEFR) of workers in a cement factory — Douglas K. E, Alasia D. D. ... history of cigarette smoking and chronic.

  5. Impact of humidification and nebulization during expiratory limb protection: an experimental bench study.

    Science.gov (United States)

    Tonnelier, Alexandre; Lellouche, François; Bouchard, Pierre Alexandre; L'Her, Erwan

    2013-08-01

    Different filtering devices are used during mechanical ventilation to avoid dysfunction of flow and pressure transducers or for airborne microorganisms containment. Water condensates, resulting from the use of humidifiers, but also residual nebulization particles may have a major influence on expiratory limb resistance. To evaluate the influence of nebulization and active humidification on the resistance of expiratory filters. A respiratory system analog was constructed using a test lung, an ICU ventilator, heated humidifiers, and a piezoelectric nebulizer. Humidifiers were connected to different types of circuits (unheated, mono-heated, new-generation and old-generation bi-heated). Five filter types were evaluated: electrostatic, heat-and-moisture exchanger, standard, specific, and internal heated high-efficiency particulate air [HEPA] filter. Baseline characteristics were obtained from each dry filter. Differential pressure measurements were carried out after 24 hours of continuous in vitro use for each condition, and after 24 hours of use with an old-generation bi-heated circuit without nebulization. While using unheated circuits, measurements had to be interrupted before 24 hours for all the filtering devices except the internal heated HEPA filter. The heat-and-moisture exchangers occluded before 24 hours with the unheated and mono-heated circuits. The circuit type, nebulization practice, and duration of use did not influence the internal heated HEPA filter resistance. Expiratory limb filtration is likely to induce several major adverse events. Expiratory filter resistance increase is due mainly to the humidification circuit type, rather than to nebulization. If filtration is mandatory while using an unheated circuit, a dedicated filter should be used for ≤ 24 hours, or a heated HEPA for a longer duration.

  6. [Visualization of laryngopharynx during swallowing of negative contrast media (air) with cine mode 64-row MDCT].

    Science.gov (United States)

    Fudeya, Taku; Otake, Shoichiro; Watabe, Hirotaka; Mitsuoka, Takashi; Yoshikawa, Akitoshi

    2010-05-20

    Video fluoroscopic examination of swallowing generally needs a contrast media such as a barium sulfate. Since the examination is usually performed in patients with dysphasia, there is a risk of aspiration. We tried to visualize the laryngopharynx during swallowing of negative contrast media (air) with 64-row multi-detector computed tomography (64-MDCT). Cine mode 64-MDCT was performed to visualize the laryngopharynx in 4 healthy volunteers during swallowing of negative contrast media (air). The data were converted to three-dimensional (3D) images of 2 conditions (air and bone) and sagittal images of the soft tissue condition at a workstation. These images were sent to a personal computer and modeled to 3D cine images with Digital Imaging and Communication in Medicine (DICOM) Viewer and Quick Time Player. 3D cine images demonstrated movements of the epiglottis, vallecula, piriform sinus, tongue, pharyngeal wall, hyoid bone and thyroid cartilage.

  7. Effects of brief smoking cessation education with expiratory carbon monoxide measurement on level of motivation to quit smoking.

    Science.gov (United States)

    Choi, Won-Young; Kim, Cheol-Hwan; Lee, Ok-Gyu

    2013-05-01

    Smoking rates among Korean adult males is still high despite multifaceted efforts to reduce it. In Korea, there have been several studies on the effectiveness of smoking cessation education for inpatients, health check-ups, and smoking cessation clinics. However, there haven't been any studies on the effectiveness of smoking cessation education conducted outside the hospital. This study investigated effectiveness of brief education on smoking cessation with an expiratory carbon monoxide (CO) measurement outside the hospital among adult male office-workers in Korea. From April 1st to May 10th, 2012, we conducted a controlled trial among 95 adult male office workers over the age of 19 who smoke outside, in a public place in Seoul by cluster sampling. For the education group, we provided smoking cessation education for about 5 to 10 minutes, measured the expiratory CO level, and made the subjects complete questionnaires, while only self-help materials on quitting smoking were given to the control group. After 4 weeks, we evaluated the change in the level of motivation or success to quit smoking in both groups via e-mail or mobile phone. In the education group, the level of motivation to quit smoking was improved significantly. A multiple logistic regression analysis showed that the odds ratio of improved motivation to quit smoking in the education group was 28.10 times higher than that of the control group. Brief education on smoking cessation with expiratory CO measurement conducted outside the hospital could enhance the level of motivation to quit smoking.

  8. A study of the short- to long-phantom dose ratios for CT scanning without table translation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xinhua; Zhang, Da; Liu, Bob, E-mail: bliu7@mgh.harvard.edu [Division of Diagnostic Imaging Physics, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 and Webster Center for Advanced Research and Education in Radiation, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Yang, Jie [Pinnacle Health - Fox Chase Regional Cancer Center, Harrisburg, Pennsylvania 17109 (United States)

    2014-09-15

    Purpose: For CT scanning in the stationary-table modes, AAPM Task Group 111 proposed to measure the midpoint dose on the central and peripheral axes of sufficiently long phantoms. Currently, a long cylindrical phantom is usually not available in many clinical facilities. The use of a long phantom is also challenging because of the heavy weight. In order to shed light on assessing the midpoint dose in CT scanning without table movement, the authors present a study of the short- to long-phantom dose ratios, and perform a cross-comparison of CT dose ratios on different scanner models. Methods: The authors performed Geant4-based Monte Carlo simulations with a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare), and modeled dosimetry measurements using a 0.6 cm{sup 3} Farmer type chamber and a 10-cm long pencil ion chamber. The short (15 cm) to long (90 cm) phantom dose ratios were computed for two PMMA diameters (16 and 32 cm), two phantom axes (the center and the periphery), and a range of beam apertures (3–25 cm). The results were compared with the published data of previous studies with other multiple detector CT (MDCT) scanners and cone beam CT (CBCT) scanners. Results: The short- to long-phantom dose ratios changed with beam apertures but were insensitive to beam qualities (80–140 kV, the head and body bowtie filters) and MDCT and CBCT scanner models. Conclusions: The short- to long-phantom dose ratios enable medical physicists to make dosimetry measurements using the standard CT dosimetry phantoms and a Farmer chamber or a 10 cm long pencil chamber, and to assess the midpoint dose in long phantoms. This method provides an effective approach for the dosimetry of CBCT scanning in the stationary-table modes, and is useful for perfusion and interventional CT.

  9. A study of the short- to long-phantom dose ratios for CT scanning without table translation

    International Nuclear Information System (INIS)

    Li, Xinhua; Zhang, Da; Liu, Bob; Yang, Jie

    2014-01-01

    Purpose: For CT scanning in the stationary-table modes, AAPM Task Group 111 proposed to measure the midpoint dose on the central and peripheral axes of sufficiently long phantoms. Currently, a long cylindrical phantom is usually not available in many clinical facilities. The use of a long phantom is also challenging because of the heavy weight. In order to shed light on assessing the midpoint dose in CT scanning without table movement, the authors present a study of the short- to long-phantom dose ratios, and perform a cross-comparison of CT dose ratios on different scanner models. Methods: The authors performed Geant4-based Monte Carlo simulations with a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare), and modeled dosimetry measurements using a 0.6 cm 3 Farmer type chamber and a 10-cm long pencil ion chamber. The short (15 cm) to long (90 cm) phantom dose ratios were computed for two PMMA diameters (16 and 32 cm), two phantom axes (the center and the periphery), and a range of beam apertures (3–25 cm). The results were compared with the published data of previous studies with other multiple detector CT (MDCT) scanners and cone beam CT (CBCT) scanners. Results: The short- to long-phantom dose ratios changed with beam apertures but were insensitive to beam qualities (80–140 kV, the head and body bowtie filters) and MDCT and CBCT scanner models. Conclusions: The short- to long-phantom dose ratios enable medical physicists to make dosimetry measurements using the standard CT dosimetry phantoms and a Farmer chamber or a 10 cm long pencil chamber, and to assess the midpoint dose in long phantoms. This method provides an effective approach for the dosimetry of CBCT scanning in the stationary-table modes, and is useful for perfusion and interventional CT

  10. The RED (reduce everyone's dose) initiative at Hinkley Point Power Station

    International Nuclear Information System (INIS)

    Weston, J.

    1995-01-01

    This paper does not offer a universal solution to reducing doses nor does it claim to introduce radically new ideas. It is a summarised account of the successes achieved in reducing the collective dose at a 30 year old power station. The key areas identified are the rewards of teamwork, the need to challenge established practices and the benefit of a dosimetry database. (author)

  11. Role of bronchodilation and pattern of breathing in increasing tidal expiratory flow with progressive induced hypercapnia in chronic obstructive pulmonary disease.

    Science.gov (United States)

    Finucane, Kevin E; Singh, Bhajan

    2018-01-01

    Hypercapnia (HC) in vitro relaxes airway smooth muscle; in vivo, it increases respiratory effort, tidal expiratory flows (V̇ exp ), and, by decreasing inspiratory duration (Ti), increases elastic recoil pressure (Pel) via lung viscoelasticity; however, its effect on airway resistance is uncertain. We examined the contributions of bronchodilation, Ti, and expiratory effort to increasing V̇ exp with progressive HC in 10 subjects with chronic obstructive pulmonary disease (COPD): mean forced expiratory volume in 1 s (FEV 1 ) 53% predicted. Lung volumes (Vl), V̇ exp , esophageal pressure (Pes), Ti, and end-tidal Pco 2 ([Formula: see text]) were measured during six tidal breaths followed by an inspiratory capacity (IC), breathing air, and at three levels of HC. V̇ exp and V̇ with submaximal forced vital capacities breathing air (V̇ sFVC ) were compared. Pulmonary resistance ( Rl) was measured from the Pes-V̇ relationship. V̇ exp and Pes at end-expiratory lung volume (EELV) + 0.3 tidal volume [V̇ (0.3Vt) and Pes (0.3Vt) , respectively], Ti, and Rl correlated with [Formula: see text] ( P pulmonary disease (COPD), progressive HC increases tidal expiratory flows by inducing bronchodilation and via an increased rate of inspiration and lung viscoelasticity, a probable increase in lung elastic recoil pressure, both changes increasing expiratory flows, promoting lung emptying and a stable end-expiratory volume. Bronchodilation with HC occurred despite optimal standard bronchodilator therapy, suggesting that in COPD further bronchodilation is possible.

  12. The effect on dose accumulation accuracy of inverse-consistency and transitivity error reduced deformation maps

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Bender, Edward T.; Tomé, Wolfgang A.

    2014-01-01

    It has previously been shown that deformable image registrations (DIRs) often result in deformation maps that are neither inverse-consistent nor transitive, and that the dose accumulation based on these deformation maps can be inconsistent if different image pathways are used for dose accumulation. A method presented to reduce inverse consistency and transitivity errors has been shown to result in more consistent dose accumulation, regardless of the image pathway selected for dose accumulation. The present study investigates the effect on the dose accumulation accuracy of deformation maps processed to reduce inverse consistency and transitivity errors. A set of lung 4DCT phases were analysed, consisting of four images on which a dose grid was created. Dose to 75 corresponding anatomical locations was manually tracked. Dose accumulation was performed between all image sets with Demons derived deformation maps as well as deformation maps processed to reduce inverse consistency and transitivity errors. The ground truth accumulated dose was then compared with the accumulated dose derived from DIR. Two dose accumulation image pathways were considered. The post-processing method to reduce inverse consistency and transitivity errors had minimal effect on the dose accumulation accuracy. There was a statistically significant improvement in dose accumulation accuracy for one pathway, but for the other pathway there was no statistically significant difference. A post-processing technique to reduce inverse consistency and transitivity errors has a positive, yet minimal effect on the dose accumulation accuracy. Thus the post-processing technique improves consistency of dose accumulation with minimal effect on dose accumulation accuracy.

  13. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT--a pooled analysis of two randomized trials

    DEFF Research Database (Denmark)

    Thomsen, Henrik S; Morcos, Sameh K

    2009-01-01

    of the LOCM were also observed in patients with GFR contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM......The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients...... with glomerular filtration rate (GFR) contrast-enhanced MDCT examinations and to compare the rates of CIN following the IV administration of low-osmolar contrast media (LOCM, iopamidol and iomeprol) and an iso-osmolar contrast medium (IOCM, iodixanol). A total of 301 adult patients...

  14. Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study.

    Science.gov (United States)

    Dahl, Michael K; Vistisen, Simon T; Koefoed-Nielsen, Jacob; Larsson, Anders

    2009-01-01

    Fluid responsiveness prediction is difficult in spontaneously breathing patients. Because the swings in intrathoracic pressure are minor during spontaneous breathing, dynamic parameters like pulse pressure variation (PPV) and systolic pressure variation (SPV) are usually small. We hypothesized that during spontaneous breathing, inspiratory and/or expiratory resistors could induce high arterial pressure variations at hypovolemia and low variations at normovolemia and hypervolemia. Furthermore, we hypothesized that SPV and PPV could predict fluid responsiveness under these conditions. Eight prone, anesthetized and spontaneously breathing pigs (20 to 25 kg) were subjected to a sequence of 30% hypovolemia, normovolemia, and 20% and 40% hypervolemia. At each volemic level, the pigs breathed in a randomized order either through an inspiratory and/or an expiratory threshold resistor (7.5 cmH2O) or only through the tracheal tube without any resistor. Hemodynamic and respiratory variables were measured during the breathing modes. Fluid responsiveness was defined as a 15% increase in stroke volume (DeltaSV) following fluid loading. Stroke volume was significantly lower at hypovolemia compared with normovolemia, but no differences were found between normovolemia and 20% or 40% hypervolemia. Compared with breathing through no resistor, SPV was magnified by all resistors at hypovolemia whereas there were no changes at normovolemia and hypervolemia. PPV was magnified by the inspiratory resistor and the combined inspiratory and expiratory resistor. Regression analysis of SPV or PPV versus DeltaSV showed the highest R2 (0.83 for SPV and 0.52 for PPV) when the expiratory resistor was applied. The corresponding sensitivity and specificity for prediction of fluid responsiveness were 100% and 100%, respectively, for SPV and 100% and 81%, respectively, for PPV. Inspiratory and/or expiratory threshold resistors magnified SPV and PPV in spontaneously breathing pigs during hypovolemia

  15. The in vivo relationship between cross-sectional area and CT dose index in abdominal multidetector CT with automatic exposure control

    Energy Technology Data Exchange (ETDEWEB)

    Meeson, S; Alvey, C M; Golding, S J, E-mail: stuart.meeson@nds.ox.ac.u [Radiology Group, Nuffield Department of Surgery, University of Oxford, John Radcliffe Hospital, Oxford OX3 9DU (United Kingdom)

    2010-06-15

    The relationship between patient cross-sectional area and both volume CT dose index (CTDI) and dose length product was explored for abdominal CT in vivo, using a 16 multidetector row CT (MDCT) scanner with automatic exposure control. During a year-long retrospective survey of patients with MDCT for symptoms of abdominal sepsis, cross-sectional areas were estimated using customised ellipses at the level of the middle of vertebra L3. The relationship between cross-sectional area and the exposure parameters was explored. Scans were performed using a LightSpeed 16 (GE Healthcare Medical Systems, Milwaukee, WI) operated with tube current modulation. From a survey of 94 patients it was found that the CTDI increased with the increase in patient cross-sectional area. The relationship was logarithmic rather than linear, with a least-squares fit to the data (R{sup 2} = 0.80). For abdominal CT the cross-sectional area gave a measure of patient size based on the region of the body to be exposed. Exposure parameters increased with increasing cross-sectional area and the greater radiation exposure of larger patients was partly a consequence of their size. Given increasing obesity levels we believe that cross-sectional area and scan length should be added to future dose surveys, allowing patient size to be considered as a factor of relevance when examining population doses.

  16. DuraSeal® as a spacer to reduce rectal doses in low-dose rate brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Heikkilä, Vesa-Pekka; Kärnä, Aarno; Vaarala, Markku H.

    2014-01-01

    The purpose of this study was to evaluate the utility of off-label use of DuraSeal® polyethylene glycol (PEG) gel in low-dose rate (LDR) prostate brachytherapy seed implantation to reduce rectal doses. Diluted DuraSeal® was easy to use and, in spite of a clearance effect, useful in decreasing D 2cc rectal doses

  17. Effect of simultaneous application of postural techniques and expiratory muscle strength training on the enhancement of the swallowing function of patients with dysphagia caused by parkinson's disease.

    Science.gov (United States)

    Byeon, Haewon

    2016-06-01

    [Purpose] This study aimed to investigate the effect of simultaneous application of postural techniques and expiratory muscle strength training on the enhancement of the swallowing function of patients with dysphagia caused by Parkinson's disease. [Subjects and Methods] The subjects of this study were 18 patients who received simultaneous application of postural techniques and expiratory muscle strength training and 15 patients who received expiratory muscle strength training only. Postural techniques were conducted in the order of chin tucking, head rotation, head tilting, bending head back, and lying down, while expiratory muscle strength training was conducted at a resistance level of about 70% of the maximal expiratory pressure. Swallowing recovery was assessed by using the Functional Dysphagia Scale based on videofluoroscopic studies. [Results] The mean value obtained in the videofluoroscopic studies for both groups decreased after the treatment. In the postural techniques plus expiratory muscle strength training group, the decrease was significantly greater than that in the expiratory muscle strength training-only group. [Conclusion] The results imply that simultaneous performance of postural techniques and expiratory muscle strength training is more effective than expiratory muscle strength training alone when applied in the swallowing rehabilitation for patients with dysphagia caused by Parkinson's disease.

  18. Radiological profile of anemia on unenhanced MDCT of the thorax

    International Nuclear Information System (INIS)

    Kamel, Ehab M.; Rizzo, Elena; Duran, Rafael; Goncalves-Matoso, Vasco; Schnyder, Pierre; Duchosal, Michel A.; Qanadli, Salah D.

    2008-01-01

    Our aim was to investigate the diagnostic value of unenhanced MDCT in anemic patients. Fifty consecutive patients with proven anemia and 50 nonanemic matched group for age, sex and body mass index were evaluated. In either group, hemoglobin levels were assessed no more than 24 h from an unenhanced CT of the thorax. For each patient, the presence of a hyperattenuating aortic wall (aortic ring sign) and/or dense interventricular septum (subjective parameters) were identified by two radiologists who were blinded to the laboratory findings. Furthermore, the aortic CT attenuation values (objective parameter) were also obtained and correlated with the hemoglobin levels. The sensitivity and specificity in detecting anemia were calculated for each variable, and ROC analysis was generated for subjective and objective parameters. Subjective image analysis revealed that the aortic ring sign was more sensitive than the interventricular septum sign for anemia detection (84% vs. 72%), whereas this latter sign was more specific (100% vs. 92%). A good correlation (r=0.60) was observed between the aortic CT attenuation values and the hemoglobin levels in the whole study population. Using a threshold of ≤35 HU for anemia diagnosis, the sensitivity and specificity of aortic CT attenuation value were 84% and 94%, respectively, with the largest area under the curve (0.89) among all diagnostic criteria. However, the best trade-off between sensitivity (80%) and specificity (100%) was obtained from combining both subjective and objective analysis. Interpreting anemia upon unnenhanced MDCT of the thorax is quite feasible. A diagnostic approach that considers both subjective and objective analysis offers the best trade-off between sensitivity and specificity. (orig.)

  19. Low dose irradiation reduces cancer mortality rates

    International Nuclear Information System (INIS)

    Luckey, T.D.

    2000-01-01

    Low doses of ionizing radiation stimulate development, growth, memory, sensual acuity, fecundity, and immunity (Luckey, T.D., ''Radiation Hormesis'', CRC Press, 1991). Increased immune competence reduces cancer mortality rates and provides increased average lifespan in animals. Decreased cancer mortality rates in atom bomb victims who received low dose irradiation makes it desirable to examine populations exposed to low dose irradiation. Studies with over 300,000 workers and 7 million person-years provide a valid comparison of radiation exposed and control unclear workers (Luckey, T.D., Nurture with Ionizing Radiation, Nutrition and Cancer, 34:1-11, 1999). Careful selection of controls eliminated any ''healthy worker effect''. The person-year corrected average indicated the cancer mortality rate of exposed workers was only 51% that of control workers. Lung cancer mortality rates showed a highly significant negative correlation with radon concentrations in 272,000 U.S. homes (Cohen, B.L., Health Physics 68:157-174, 1995). In contrast, radon concentrations showed no effect on lung cancer rates in miners from different countries (Lubin, J.H. Am. J. Epidemiology 140:323-332, 1994). This provides evidence that excessive lung cancer in miners is caused by particulates (the major factor) or toxic gases. The relative risk for cancer mortality was 3.7% in 10,000 Taiwanese exposed to low level of radiation from 60 Co in their steel supported homes (Luan, Y.C. et al., Am. Nuclear Soc. Trans. Boston, 1999). This remarkable finding needs further study. A major mechanism for reduced cancer mortality rates is increased immune competence; this includes both cell and humoral components. Low dose irradiation increases circulating lymphocytes. Macrophage and ''natural killer'' cells can destroy altered (cancer) cells before the mass becomes too large. Low dose irradiation also kills suppressor T-cells; this allows helper T-cells to activate killer cells and antibody producing cells

  20. Abdominal Hernias, Giant Colon Diverticulum, GIST, Intestinal Pneumatosis, Colon Ischemia, Cold Intussusception, Gallstone Ileus, and Foreign Bodies: Our Experience and Literature Review of Incidental Gastrointestinal MDCT Findings

    OpenAIRE

    Di Grezia, G.; Gatta, G.; Rella, R.; Donatello, D.; Falco, G.; Grassi, R.; Grassi, R.

    2017-01-01

    Incidental gastrointestinal findings are commonly detected on MDCT exams performed for various medical indications. This review describes the radiological MDCT spectrum of appearances already present in the past literature and in today’s experience of several gastrointestinal acute conditions such as abdominal hernia, giant colon diverticulum, GIST, intestinal pneumatosis, colon ischemia, cold intussusception, gallstone ileus, and foreign bodies which can require medical and surgical interven...

  1. Age group classification and gender detection based on forced expiratory spirometry.

    Science.gov (United States)

    Cosgun, Sema; Ozbek, I Yucel

    2015-08-01

    This paper investigates the utility of forced expiratory spirometry (FES) test with efficient machine learning algorithms for the purpose of gender detection and age group classification. The proposed method has three main stages: feature extraction, training of the models and detection. In the first stage, some features are extracted from volume-time curve and expiratory flow-volume loop obtained from FES test. In the second stage, the probabilistic models for each gender and age group are constructed by training Gaussian mixture models (GMMs) and Support vector machine (SVM) algorithm. In the final stage, the gender (or age group) of test subject is estimated by using the trained GMM (or SVM) model. Experiments have been evaluated on a large database from 4571 subjects. The experimental results show that average correct classification rate performance of both GMM and SVM methods based on the FES test is more than 99.3 % and 96.8 % for gender and age group classification, respectively.

  2. Are hepatic portal venous system components distributed equally to the liver? A MDCT study

    International Nuclear Information System (INIS)

    Incedayi, M.; Aribal, S.; Sivrioglu, A.; Sonmez, G.; Ozturk, E.; Yalcin, B.; Basekim, C.

    2012-01-01

    Full text: Objective: We aimed to evaluate the relationships between the splenic index, right and left hepatic lobe volumes, diameters of splenic vein (SV), superior mesenteric vein (SMV) and the portal vein (PV) by Multidetector Computerized Tomography (MDCT). We also investigated indirect signs of portal venous flow pattern using these parameters. Material and method: Following their contrast thoracoabdominal and abdominal 64-MDCT examinations, the images of 100 cases (61 males and 39 females) were evaluated retrospectively. The patients who were included in the study ranged from age 20 to 88 (mean age: 41,78). For each case, the splenic index, total hepatic volume, left and right hepatic volumes were calculated on the post-contrast portal venous phase (50th sec) images. Cases without any known liver and spleen diseases were included in the study. Spearman and Pearson's correlation tests were carried out with the purpose of determining the relationships between the variables. Results: A statistically significant relationship between the splenic index and left hepatic lobe volume and total volume was demonstrated (p=0.001). Positive correlations between the left hepatic lobe volume and splenic index (r=0.55) and between the right hepatic lobe volume and splenic index (r=0.32) were also exhibited. However, the correlation between the left hepatic lobe volume and the splenic index was relatively stronger compared to the correlation between the right hepatic lobe volume and the splenic index (r=0.55 versus r= 0.32). Between the diameter of the SMV and right hepatic lobe volume a statistically significant relation was demonstrated (p<0.0001), and according to Pearson's correlation analysis, a positive correlation of medium strength (r=0.36) was observed. Conclusion: In our study, the MDCT findings revealed statistically significant relations between the splenic index and the left lobe volume and between the diameter of the SMV and the right lobe volume. Information

  3. Pulmonary emphysema quantitation with Computed Tomography. Comparison between the visual score with high resolution CT, expiratory density mask with spiral CT and lung function studies

    International Nuclear Information System (INIS)

    Zompatori, Maurizio; Battaglia, Milva; Rimondi, Maria Rita; Vivacqua, Donatella; Biscarini, Manuela; Fasano, Luca; Pacilli, Angela Maria Grazia; Guerrieri, Aldo; Fabbri, Mario; Cavina, Mauro

    1997-01-01

    CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of expiratory airflow obstruction and gas diffusion impairment (visual score versus forced expiratory volume in one second: r = -0.81, versus single breath carbon monoxide diffusion: r = -0.78. Spiral expiratory density mask -850 HU versus forced expiratory volume in one second: r = -0.85 versus single breath carbon monoxide diffusion: r = -0.77). When -900 HU was used as the cut-off value for the expiratory density mask, the correlation with single breath carbon monoxide diffusion worsened (r = -0.56). Visual score and expiratory density mask -850 HU gave similar results and permitted COPD patients to be clearly distinguished from normal controls (p < 0.01). They believe the true residual volume should lie somewhere in between the CT value and the function results with the helium dilution technique and conclude that the extent of pulmonary emphysema can be confidently assessed with CT methods. Finally, the simple visual score may be as reliable as such highly sophisticated new methods as the spiral expiratory density mask

  4. Usefulness of multidetector-row CT (MDCT) for the diagnosis of non-occlusive mesenteric ischemia (NOMI): Assessment of morphology and diameter of the superior mesenteric artery (SMA) on multi-planar reconstructed (MPR) images

    International Nuclear Information System (INIS)

    Woodhams, Reiko; Nishimaki, Hiroshi; Fujii, Kaoru; Kakita, Satoko; Hayakawa, Kazushige

    2010-01-01

    Objective: The purpose of this study was to assess the efficacy of multidetector-row CT (MDCT) for the diagnosis of non-occlusive mesenteric ischemia (NOMI) by analyzing morphology and diameter of superior mesenteric artery (SMA). We assessed whether MDCT was as useful as angiography for the diagnosis of NOMI. Materials and methods: Four patients who were diagnosed with NOMI were retrospectively analyzed. All patients had 8-row MDCT followed by laparotomy. Two of them underwent angiography after MDCT. The morphology and diameter of SMA of these cases was analyzed on multi-planar reconstructed (MPR) images. The mean diameter of SMA of NOMI cases was compared to that of 13 control cases. Results: MPR images of all NOMI cases showed irregular narrowing of the SMA, spasm of the arcades of SMA, and poor demonstration of intramural vessels. MPR images of two patients who had angiography were concordant with their angiograms. The mean diameter of SMA of NOMI patients was 3.4 ± 1.1 mm, which was statistically smaller than that of 13 control patients, 6.0 ± 1.5 mm (P < 0.05, Wilcoxon rank sum tests). Conclusion: Angiography has been recognized essential for the diagnosis of NOMI. This study shows the possibility of MDCT to be an equivalently useful modality compared to angiography for the diagnosis of NOMI by interpreting morphologic appearance and diameter of SMA. Introduction of MDCT in the decision tree of NOMI treatment may bring the benefit of prompt diagnosis and subsequent early and efficient initiation of therapy, which may improve the mortality.

  5. Abdominal 64-MDCT for suspected appendicitis: the use of oral and IV contrast material versus IV contrast material only.

    Science.gov (United States)

    Anderson, Stephan W; Soto, Jorge A; Lucey, Brian C; Ozonoff, Al; Jordan, Jacqueline D; Ratevosian, Jirair; Ulrich, Andrew S; Rathlev, Niels K; Mitchell, Patricia M; Rebholz, Casey; Feldman, James A; Rhea, James T

    2009-11-01

    The objective of our study was to compare the diagnostic accuracy of IV contrast-enhanced 64-MDCT with and without the use of oral contrast material in diagnosing appendicitis in patients with abdominal pain. We conducted a randomized trial of a convenience sample of adult patients presenting to an urban academic emergency department with acute nontraumatic abdominal pain and clinical suspicion of appendicitis, diverticulitis, or small-bowel obstruction. Patients were enrolled between 8 am and 11 pm when research assistants were present. Consenting subjects were randomized into one of two groups: Group 1 subjects underwent 64-MDCT performed with oral and IV contrast media and group 2 subjects underwent 64-MDCT performed solely with IV contrast material. Three expert radiologists independently reviewed the CT examinations, evaluating for the presence of appendicitis. Each radiologist interpreted 202 examinations, ensuring that each examination was interpreted by two radiologists. Individual reader performance and a combined interpretation performance of the two readers assigned to each case were calculated. In cases of disagreement, the third reader was asked to deliver a tiebreaker interpretation to be used to calculate the combined reader performance. Final outcome was based on operative, clinical, and follow-up data. We compared radiologic diagnoses with clinical outcomes to calculate the diagnostic accuracy of CT in both groups. Of the 303 patients enrolled, 151 patients (50%) were randomized to group 1 and the remaining 152 (50%) were randomized to group 2. The combined reader performance for the diagnosis of appendicitis in group 1 was a sensitivity of 100% (95% CI, 76.8-100%) and specificity of 97.1% (95% CI, 92.7-99.2%). The performance in group 2 was a sensitivity of 100% (73.5-100%) and specificity of 97.1% (92.9-99.2%). Patients presenting with nontraumatic abdominal pain imaged using 64-MDCT with isotropic reformations had similar characteristics for the

  6. Reducing ionizing radiation doses during cardiac interventions in pregnant women.

    Science.gov (United States)

    Orchard, Elizabeth; Dix, Sarah; Wilson, Neil; Mackillop, Lucy; Ormerod, Oliver

    2012-09-01

    There is concern over ionizing radiation exposure in women who are pregnant or of child-bearing age. Due to the increasing prevalence of congenital and acquired heart disease, the number of women who require cardiac interventions during pregnancy has increased. We have developed protocols for cardiac interventions in pregnant women and women of child-bearing age, aimed at substantially reducing both fluoroscopy duration and radiation doses. Over five years, we performed cardiac interventions on 15 pregnant women, nine postpartum women and four as part of prepregnancy assessment. Fluoroscopy times were minimized by simultaneous use of intracardiac echocardiography, and by using very low frame rates (2/second) during fluoroscopy. The procedures most commonly undertaken were closure of atrial septal defect (ASD) or patent foramen ovale (PFO) in 16 women, coronary angiograms in seven, right and left heart catheters in three and two stent placements. The mean screening time for all patients was 2.38 minutes (range 0.48-13.7), the median radiation dose was 66 (8.9-1501) Gy/cm(2). The median radiation dose to uterus was 1.92 (0.59-5.47) μGy, and the patient estimated dose was 0.24 (0.095-0.80) mSv. Ionizing radiation can be used safely in the management of severe cardiac structural disease in pregnancy, with very low ionizing radiation dose to the mother and extremely low exposure to the fetus. With experience, ionizing radiation doses at our institution have been reduced.

  7. Comparison of biophysical factors influencing on emphysema quantification with low-dose CT

    Science.gov (United States)

    Heo, Chang Yong; Kim, Jong Hyo

    2014-03-01

    Emphysema Index(EI) measurements in MDCT is known to be influenced by various biophysical factors such as total lung volume, and body size. We investigated the association of the four biophysical factors with emphysema index in low-dose MDCT. In particular, we attempted to identify a potentially stronger biophysical factor than total lung volume. A total of 400 low-dose MDCT volumes taken at 120kVp, 40mAs, 1mm thickness, and B30f reconstruction kernel were used. The lungs, airways, and pulmonary vessels were automatically segmented, and two Emphysema Indices, relative area below -950HU(RA950) and 15th percentile(Perc15), were extracted from the segmented lungs. The biophysical factors such as total lung volume(TLV), mode of lung attenuation(ModLA), effective body diameter(EBD), and the water equivalent body diameter(WBD) were estimated from the segmented lung and body area. The association of biophysical factors with emphysema indices were evaluated by correlation coefficients. The mean emphysema indices were 8.3±5.5(%) in RA950, and -930±18(HU) in Perc15. The estimates of biophysical factors were 4.7±1.0(L) in TLV, -901±21(HU) in ModLA, 26.9±2.2(cm) in EBD, and 25.9±2.6(cm) in WBD. The correlation coefficients of biophysical factors with RA950 were 0.73 in TLV, 0.94 in ModLA, 0.31 in EBD, and 0.18 WBD, the ones with Perc15 were 0.74 in TLV, 0.98 in ModLA, 0.29 in EBD, and 0.15 WBD. Study results revealed that two biophysical factors, TLV and ModLA, mostly affects the emphysema indices. In particular, the ModLA exhibited strongest correlation of 0.98 with Perc15, which indicating the ModLA is the most significant confounding biophysical factor in emphysema indices measurement.

  8. HALF-DOSE DEPOT TRIPTORELIN COMPARABLE TO REDUCED DAILY BUSERELIN: A RANDOMIZED CLINICAL TRIAL

    Directory of Open Access Journals (Sweden)

    L. Safdarian

    2007-09-01

    Full Text Available Pituitary suppression by depot GnRH agonist may be excessive for ovarian stimulation. This study compares the efficacy of a single half-dose depot triptorelin and reduced-dose daily buserelin in a long protocol ICSI/ET. METHODS: A total of 182 patients were randomized into two groups using sealed envelopes. Pituitary desensitization was obtained in group 1 (91 patients with half-dose (1.87 mg depot triptorelin in the mid-luteal phase of their menstrual cycle, and in group 2 (91 patients with standard daily dose (0.5 mg buserelin, which was then reduced to 0.25 mg at the start of human menopausal gonadotropin (HMG stimulation. RESULTS: No significant differences were found among those who received HCG in terms of clinical pregnancy rate (34.4% in both groups, implantation rate (14.8% in group 1 versus 11.1% in group 2, fertilization rate (93.3 versus 95.6%, poor response rate (11.1 versus 6.7%, and miscarriage rate (11.1 versus 7.8%. No significant differences were seen in number of HMG ampoules used, follicles at HCG administration, and oocytes retrieved. The number of days of stimulation was significantly reduced in group 2 (11.2 +/- 1.8 in group 1 versus 10.6 +/- 1.9, p = 0.030. CONCLUSION: A half-dose of depot triptorelin can be successfully used in ovarian stimulation instead of reduced-dose daily buserelin, with more patient comfort and reduced stress and cost of injections.

  9. An asthma patient with steroid-resistant decrease in peak expiratory flow after the Great East Japan earthquake showing spontaneous recovery after 1 month.

    Science.gov (United States)

    Yanagimoto, Shintaro; Haida, Michiko; Suko, Matsunobu

    2012-01-01

    People living in Japan were affected in various ways after the Great East Japan earthquake of March 11, 2011. A 52-year-old female asthma patient not directly affected by the disaster experienced a decrease in peak expiratory flow (PEF) immediately after the earthquake. Despite increasing the inhaled and oral corticosteroid doses, her PEF did not recover. One month later, her PEF level abruptly returned to normal with minimal medications, which were previously ineffective, and the asthma-related symptoms vanished. The stabilization of her state of mind and actual social state seemed to be a part of the reason for the patient's recovery.

  10. Quantitative right and left ventricular functional analysis during gated whole-chest MDCT: A feasibility study comparing automatic segmentation to semi-manual contouring

    International Nuclear Information System (INIS)

    Coche, Emmanuel; Walker, Matthew J.; Zech, Francis; Crombrugghe, Rodolphe de; Vlassenbroek, Alain

    2010-01-01

    Purpose: To evaluate the feasibility of an automatic, whole-heart segmentation algorithm for measuring global heart function from gated, whole-chest MDCT images. Material and methods: 15 patients with suspicion of PE underwent whole-chest contrast-enhanced MDCT with retrospective ECG synchronization. Two observers computed right and left ventricular functional indices using a semi-manual and an automatic whole-heart segmentation algorithm. The two techniques were compared using Bland-Altman analysis and paired Student's t-test. Measurement reproducibility was calculated using intraclass correlation coefficient. Results: Ventricular analysis with automatic segmentation was successful in 13/15 (86%) and in 15/15 (100%) patients for the right ventricle and left ventricle, respectively. Reproducibility of measurements for both ventricles was perfect (ICC: 1.00) and very good for automatic and semi-manual measurements, respectively. Ventricular volumes and functional indices except right ventricular ejection fraction obtained from the automatic method were significantly higher for the RV compared to the semi-manual methods. Conclusions: The automatic, whole-heart segmentation algorithm enabled highly reproducible global heart function to be rapidly obtained in patients undergoing gated whole-chest MDCT for assessment of acute chest pain with suspicion of pulmonary embolism.

  11. THE EFFECT OF SUBMAXIMAL INHALATION ON MEASURES DERIVED FROM FORCED EXPIRATORY SPIROMETRY

    Science.gov (United States)

    THE EFFECT OF SUBMAXIMAL INHALATION ON MEASURES DERIVED FROM FORCED EXPIRATORY SPIROMETRY. William F. McDonnell Human Studies Division, NHEERL, U.S. Environmental Protection Agency, RTP, NC 27711. Short-term exposure to ozone results in a neurally-mediated decrease in the ab...

  12. Changes in forced expiratory volume in 1 second over time in COPD

    DEFF Research Database (Denmark)

    Vestbo, Jørgen; Edwards, Lisa D; Scanlon, Paul D

    2011-01-01

    A key feature of chronic obstructive pulmonary disease (COPD) is an accelerated rate of decline in forced expiratory volume in 1 second (FEV(1)), but data on the variability and determinants of this change in patients who have established disease are scarce....

  13. New technologies to reduce pediatric radiation doses

    International Nuclear Information System (INIS)

    Bernhardt, Philipp; Lendl, Markus; Deinzer, Frank

    2006-01-01

    X-ray dose reduction in pediatrics is particularly important because babies and children are very sensitive to radiation exposure. We present new developments to further decrease pediatric patient dose. With the help of an advanced exposure control, a constant image quality can be maintained for all patient sizes, leading to dose savings for babies and children of up to 30%. Because objects of interest are quite small and the speed of motion is high in pediatric patients, short pulse widths down to 4 ms are important to reduce motion blurring artifacts. Further, a new noise-reduction algorithm is presented that detects and processes signal and noise in different frequency bands, generating smooth images without contrast loss. Finally, we introduce a super-resolution technique: two or more medical images, which are shifted against each other in a subpixel region, are combined to resolve structures smaller than the size of a single pixel. Advanced exposure control, short exposure times, noise reduction and super-resolution provide improved image quality, which can also be invested to save radiation exposure. All in all, the tools presented here offer a large potential to minimize the deterministic and stochastic risks of radiation exposure. (orig.)

  14. A study of diurnal variation in peak expiratory flow rates in healthy adult female subjects in South India

    Directory of Open Access Journals (Sweden)

    Jenny Jayapal

    2014-01-01

    Full Text Available Background: Peak Expiratory Flow Rate (PEFR reflects the strength and condition of respiratory muscles and the degree of airflow limitation in large airways. PEFR shows hour to hour variation that follows a specific pattern in asthmatics and healthy individuals. Adequate data is not available for the diurnal variation in normal individuals who are students in professional courses and had a sedentary life style. Hence, this study was undertaken to study the diurnal variation in peak expiratory flow rates in healthy adult female subjects in South India. Materials and Methods: Peak expiratory flow rate was recorded in 50 adult healthy female students aged 18-23 years and studying in professional courses. Mini Wright′s peak flow meter was used to measure the peak expiratory flow rate. PEFR were recorded at 7-8 a.m., 10-11 a.m., 1-2 p.m., 4-5 p.m., and 7-8 p.m. for two consecutive days. Results: On analysis of PEFR records of individual subjects, it was seen that there was an overall dip in the morning at 7-8 h PEFR, which increased in the daytime, peaking in the afternoon at 1-2 p.m. and eventually decreased in the night. Subjects did not show the peak PEFR values at the same time point, 10% of subjects had a rise in PEFR in the early morning, afternoon (1-2 p.m. peak was observed in 48% subjects and evening (4-5 p.m. peak was observed in 16% subjects. 14% subjects showed a peak in the night time (7-8 p.m. PEFR values. Conclusion: This study provided the preliminary reference data of diurnal variation of peak expiratory flow rate in healthy adults. Since, there is a variation in the peak expiratory flow rate recorded during different time points of the day; hence, to compare the PEFR between individuals it is advisable to record the PEFR at the same time point.

  15. Hand grip strength and maximum peak expiratory flow: determinants of bone mineral density of adolescent students.

    Science.gov (United States)

    Cossio-Bolaños, Marco; Lee-Andruske, Cynthia; de Arruda, Miguel; Luarte-Rocha, Cristian; Almonacid-Fierro, Alejandro; Gómez-Campos, Rossana

    2018-03-02

    Maintaining and building healthy bones during the lifetime requires a complicated interaction between a number of physiological and lifestyle factors. Our goal of this study was to analyze the association between hand grip strength and the maximum peak expiratory flow with bone mineral density and content in adolescent students. The research team studied 1427 adolescent students of both sexes (750 males and 677 females) between the ages of 11.0 and 18.9 years in the Maule Region of Talca (Chile). Weight, standing height, sitting height, hand grip strength (HGS), and maximum peak expiratory flow (PEF) were measured. Furthermore, bone mineral density (BMD) and total body bone mineral content (BMC) were determined by using the Dual-Energy X-Ray Absorptiometry (DXA). Hand grip strength and PEF were categorized in tertiles (lowest, middle, and highest). Linear regression was performed in steps to analyze the relationship between the variables. Differences between categories were determined through ANOVA. In males, the hand grip strength explained 18-19% of the BMD and 20-23% of the BMC. For the females, the percentage of variation occurred between 12 and 13% of the BMD and 17-18% of the BMC. The variation of PEF for the males was observed as 33% of the BMD and 36% of the BMC. For the females, both the BMD and BMC showed a variation of 19%. The HGS and PEF were divided into three categories (lowest, middle, and highest). In both cases, significant differences occurred in bone density health between the three categories. In conclusion, the HGS and the PEF related positively to the bone density health of both sexes of adolescent students. The adolescents with poor values for hand grip strength and expiratory flow showed reduced values of BMD and BMC for the total body. Furthermore, the PEF had a greater influence on bone density health with respect to the HGS of the adolescents of both sexes.

  16. Dangerous Pressurization and Inappropriate Alarms during Water Occlusion of the Expiratory Circuit of Commonly Used Infant Ventilators.

    Directory of Open Access Journals (Sweden)

    Murray Hinder

    Full Text Available Non-invasive continuous positive airways pressure is commonly a primary respiratory therapy delivered via multi-purpose ventilators in premature newborns. Expiratory limb occlusion due to water accumulation or 'rainout' from gas humidification is a frequent issue. A case of expiratory limb occlusion due to rainout causing unexpected and excessive repetitive airway pressurisation in a Draeger VN500 prompted a systematic bench test examination of currently available ventilators.To assess neonatal ventilator response to partial or complete expiratory limb occlusion when set to non-invasive continuous positive airway pressure mode.Seven commercially available neonatal ventilators connected to a test lung using a standard infant humidifier circuit with partial and/or complete expiratory limb occlusion were examined in a bench test study. Each ventilator was set to deliver 6 cmH2O in non-invasive mode and respiratory mechanics data for 75%, 80% and 100% occlusion were collected.Several ventilators responded inappropriately with complete occlusion by cyclical pressurisation/depressurisation to peak pressures of between 19·4 and 64·6 cm H2O at rates varying between 2 to 77 inflations per minute. Tidal volumes varied between 10·1 and 24·3mL. Alarm responses varied from 'specific' (tube occluded to 'ambiguous' (Safety valve open. Carefusion Avea responded by continuing to provide the set distending pressure and displaying an appropriate alarm message. Draeger Babylog 8000 did not alarm with partial occlusions and incorrectly displayed airways pressure at 6·1cmH2O compared to the measured values of 13cmH2O.This study found a potential for significant adverse ventilator response due to complete or near complete expiratory limb occlusion in CPAP mode.

  17. Reducing radiation dose to the female breast during conventional and dedicated breast computed tomography

    Science.gov (United States)

    Rupcich, Franco John

    The purpose of this study was to quantify the effectiveness of techniques intended to reduce dose to the breast during CT coronary angiography (CTCA) scans with respect to task-based image quality, and to evaluate the effectiveness of optimal energy weighting in improving contrast-to-noise ratio (CNR), and thus the potential for reducing breast dose, during energy-resolved dedicated breast CT. A database quantifying organ dose for several radiosensitive organs irradiated during CTCA, including the breast, was generated using Monte Carlo simulations. This database facilitates estimation of organ-specific dose deposited during CTCA protocols using arbitrary x-ray spectra or tube-current modulation schemes without the need to run Monte Carlo simulations. The database was used to estimate breast dose for simulated CT images acquired for a reference protocol and five protocols intended to reduce breast dose. For each protocol, the performance of two tasks (detection of signals with unknown locations) was compared over a range of breast dose levels using a task-based, signal-detectability metric: the estimator of the area under the exponential free-response relative operating characteristic curve, AFE. For large-diameter/medium-contrast signals, when maintaining equivalent AFE, the 80 kV partial, 80 kV, 120 kV partial, and 120 kV tube-current modulated protocols reduced breast dose by 85%, 81%, 18%, and 6%, respectively, while the shielded protocol increased breast dose by 68%. Results for the small-diameter/high-contrast signal followed similar trends, but with smaller magnitude of the percent changes in dose. The 80 kV protocols demonstrated the greatest reduction to breast dose, however, the subsequent increase in noise may be clinically unacceptable. Tube output for these protocols can be adjusted to achieve more desirable noise levels with lesser dose reduction. The improvement in CNR of optimally projection-based and image-based weighted images relative to photon

  18. Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocol

    Energy Technology Data Exchange (ETDEWEB)

    Trad, Henrique Simao; Boasquevisque, Gustavo Santos; Giacometti, Tiago Rangon; Trad, Catherine Yang; Zoghbi Neto, Orlando Salomao; Trad, Clovis Simao, E-mail: hsimtrad@gmail.com [Central de Diagnostico Ribeirao Preto (CEDIRP), Ribeirao Preto, SP (Brazil)

    2016-03-15

    Objective: To propose a protocol for pulmonary angiography using 64-slice multidetector computed tomography (64-MDCT) with 50 mL of iodinated contrast material, in an unselected patient population, as well as to evaluate vascular enhancement and image quality. Materials and methods: We evaluated 29 patients (22-86 years of age). The body mass index ranged from 19.0 kg/m{sup 2} to 41.8 kg/m{sup 2}. Patients underwent pulmonary CT angiography in a 64-MDCT scanner, receiving 50 mL of iodinated contrast material via venous access at a rate of 4.5 mL/s. Bolus tracking was applied in the superior vena cava. Two experienced radiologists assessed image quality and vascular enhancement. Results: The mean density was 382 Hounsfield units (HU) for the pulmonary trunk; 379 and 377 HU for the right and left main pulmonary arteries, respectively; and 346 and 364 HU for the right and left inferior pulmonary arteries, respectively. In all patients, subsegmental arteries were analyzed. There were streak artifacts from contrast material in the superior vena cava in all patients. However, those artifacts did not impair the image analysis. Conclusion: Our findings suggest that pulmonary angiography using 64-MDCT with 50 mL of iodinated contrast can produce high quality images in unselected patient populations. (author)

  19. Automatic individualized contrast medium dosage during hepatic computed tomography by using computed tomography dose index volume (CTDI{sub vol})

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Anders; Cederlund, Kerstin; Aspelin, Peter; Brismar, Torkel B. [Intervention and Technology at Karolinska Institutet, Department of Clinical Science, Division of Medical Imaging and Technology, Stockholm (Sweden); Karolinska University Hospital in Huddinge, Department of Radiology, Stockholm (Sweden); Bjoerk, Jonas [FoU-centrum Skaane Skaanes Universitetssjukhus i Lund, Lund (Sweden); Nyman, Ulf [University of Lund, Department of Diagnostic Radiology, Lasarettet Trelleborg, Trelleborg (Sweden)

    2014-08-15

    To compare hepatic parenchymal contrast media (CM) enhancement during multi-detector row computed tomography (MDCT) and its correlation with volume pitch-corrected computed tomography dose index (CTDI{sub vol}) and body weight (BW). One hundred patients referred for standard three-phase thoraco-abdominal MDCT examination were enrolled. BW was measured in the CT suite. Forty grams of iodine was administered intravenously (iodixanol 320 mg I/ml at 5 ml/s or iomeprol 400 mg I/ml at 4 ml/s) followed by a 50-ml saline flush. CTDI{sub vol} presented by the CT equipment during the parenchymal examination was recorded. The CM enhancement of the liver was defined as the attenuation HU of the liver parenchyma during the hepatic parenchymal phase minus the attenuation in the native phase. Liver parenchymal enhancement was negatively correlated to both CTDI{sub vol} (r = -0.60) and BW (r = -0.64), but the difference in correlation between those two was not significant. CTDI{sub vol} may replace BW when adjusting CM doses to body size. This makes it potentially feasible to automatically individualize CM dosage by CT. (orig.)

  20. Quantification of arterial plaque and lumen density with MDCT

    International Nuclear Information System (INIS)

    Paul, Narinder S.; Blobel, Joerg; Kashani, Hany; Rice, Murray; Ursani, Ali

    2010-01-01

    Purpose: This study aimed to derive a mathematical correction function in order to normalize the CT number measurements for small volume arterial plaque and small vessel mimicking objects, imaged with multidetector CT (MDCT). Methods: A commercially available calcium plaque phantom (QRM GmbH, Moehrendorf, Germany) and a custom built cardiovascular phantom were scanned with 320 and 64 MDCT scanners. The calcium hydroxyapatite plaque phantom contained objects 0.5-5.0 mm in diameter with known CT attenuation nominal values ranging 50-800 HU. The cardiovascular phantom contained vessel mimicking objects 1.0-5.0 mm in diameter with different contrast media. Both phantoms were scanned using clinical protocols for CT angiography and images were reconstructed with different filter kernels. The measured CT number (HU) and diameter of each object were analyzed on three clinical postprocessing workstations. From the resultant data, a mathematical formula was derived based on absorption function exp(-μ * d) to demonstrate the relation between measured CT numbers and object diameters. Results: The percentage reduction in measured CT number (HU) for the group of selected filter kernels, apparent during CT angiography, is dependent only on the object size (plaque or vessel diameter). The derived formula of the form 1-c * exp(-a * d b ) showed reduction in CT number for objects between 0.5 and 5 mm in diameter, with asymptote reaching background noise for small objects with diameters nearing the CT in-plane resolution (0.35 mm). No reduction was observed for the objects with diameters equal or larger than 5 mm. Conclusions: A clear mathematical relationship exists between object diameter and reduction in measured CT number in HU. This function is independent of exposure parameters and inherent attenuation properties of the objects studied. Future developments include the incorporation of this mathematical model function into quantification software in order to automatically

  1. Reducing radiation doses to the breast, thyroid and gonads during diagnostic radiography

    International Nuclear Information System (INIS)

    Weatherburn, G.C.

    1983-01-01

    The skin entry and exit doses on patients undergoing routine radiographic examinations of areas in which the breast, thyroid and gonads are included in the primary beam were measured using thermoluminescent dosimeters. To obtain further information about patient doses, measurements were also made on a phantom at similar skin positions and at the positions of these organs. Comparisons of the doses to these radiosensitive organs were made for the antero-posterior and postero-anterior projections. In cases where it was found that the doses were reduced by the use of non-conventional relationship between the relative positions of the patient and the film, suggestions are made for the adaptations which would have to be made to X-ray equipment to enable these projections to be taken routinely. Other techniques, such as air gap techniques and thyroid shielding, whereby patient doses can be reduced during routine radiography are also examined. Finally the implications of these results for radiation protection of patients are considered. (author)

  2. Deep learning enables reduced gadolinium dose for contrast-enhanced brain MRI.

    Science.gov (United States)

    Gong, Enhao; Pauly, John M; Wintermark, Max; Zaharchuk, Greg

    2018-02-13

    There are concerns over gadolinium deposition from gadolinium-based contrast agents (GBCA) administration. To reduce gadolinium dose in contrast-enhanced brain MRI using a deep learning method. Retrospective, crossover. Sixty patients receiving clinically indicated contrast-enhanced brain MRI. 3D T 1 -weighted inversion-recovery prepped fast-spoiled-gradient-echo (IR-FSPGR) imaging was acquired at both 1.5T and 3T. In 60 brain MRI exams, the IR-FSPGR sequence was obtained under three conditions: precontrast, postcontrast images with 10% low-dose (0.01mmol/kg) and 100% full-dose (0.1 mmol/kg) of gadobenate dimeglumine. We trained a deep learning model using the first 10 cases (with mixed indications) to approximate full-dose images from the precontrast and low-dose images. Synthesized full-dose images were created using the trained model in two test sets: 20 patients with mixed indications and 30 patients with glioma. For both test sets, low-dose, true full-dose, and the synthesized full-dose postcontrast image sets were compared quantitatively using peak-signal-to-noise-ratios (PSNR) and structural-similarity-index (SSIM). For the test set comprised of 20 patients with mixed indications, two neuroradiologists scored blindly and independently for the three postcontrast image sets, evaluating image quality, motion-artifact suppression, and contrast enhancement compared with precontrast images. Results were assessed using paired t-tests and noninferiority tests. The proposed deep learning method yielded significant (n = 50, P 5 dB PSNR gains and >11.0% SSIM). Ratings on image quality (n = 20, P = 0.003) and contrast enhancement (n = 20, P deep learning method, gadolinium dose can be reduced 10-fold while preserving contrast information and avoiding significant image quality degradation. 3 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  3. Reducing radiation doses to the breast, thyroid and gonads during diagnostic radiography

    International Nuclear Information System (INIS)

    Weatherburn, G.C.

    1983-01-01

    The measurement of doses to the gonads during radiography of the pelvis is discussed. Phantom measurements to estimate doses to the ovaries in antero-posterior (AP) and postero-anterior (PA) projections of the pelvis showed that the dose is 15% of the skin entry dose in the AP projection and 9% in the PA projection. The air gap technique and its applications in reducing radiation doses to the gonads, breast and thyroid is described. A summary of dose reduction factors for these radiosensitive organs achieved by modified radiographic techniques in radiography of the chest, pelvis, spine and skull is given. (U.K.)

  4. Short-term effects of positive expiratory airway pressure in patients being weaned from mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Marcelo de Mello Rieder

    2009-05-01

    Full Text Available OBJECTIVE: To investigate the feasibility and the cardiorespiratory effects of using positive expiratory airway pressure, a physiotherapeutic tool, in comparison with a T-tube, to wean patients from mechanical ventilation. METHODS/DESIGN: A prospective, randomized, cross-over study. SETTING: Two intensive care units. PATIENTS AND INTERVENTIONS: We evaluated forty patients who met weaning criteria and had been mechanically-ventilated for more than 48 hours, mean age 59 years, including 23 males. All patients were submitted to the T-tube and Expiratory Positive Airway Pressure devices, at 7 cm H2O, during a 30-minute period. Cardiorespiratory variables including work of breathing, respiratory rate (rr, peripheral oxygen saturation (SpO2, heart rate (hr, systolic, diastolic and mean arterial pressures (SAP, DAP, MAP were measured in the first and thirtieth minutes. The condition was analyzed as an entire sample set (n=40 and was also divided into subconditions: chronic obstructive pulmonary disease (n=14 and non-chronic obstructive pulmonary disease (non- chronic obstructive pulmonary disease (n=26 categories. Comparisons were made using a t-test and Analysis of Variance. The level of significance was p < 0.05. RESULTS: Our data showed an increase in work of breathing in the first and thirtieth minutes in the EPAP condition (0.86+ 0.43 and 1.02+1.3 as compared with the T-tube condition (0.25+0.26 and 0.26+0.35 (p<0.05, verified by the flow-sensor monitor (values in J/L. No statistical differences were observed when comparing the Expiratory Positive Airway Pressure and T-tube conditions with regard to cardiorespiratory measurements. The same result was observed for both chronic obstructive pulmonary disease and non- chronic obstructive pulmonary disease subconditions. CONCLUSIONS: Our study demonstrated that, in weaning patients from mechanical ventilation, the use of a fixed level of Expiratory Positive Airway Pressure caused an increase in work of

  5. Image Quality of 3rd Generation Spiral Cranial Dual-Source CT in Combination with an Advanced Model Iterative Reconstruction Technique: A Prospective Intra-Individual Comparison Study to Standard Sequential Cranial CT Using Identical Radiation Dose.

    Science.gov (United States)

    Wenz, Holger; Maros, Máté E; Meyer, Mathias; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O; Flohr, Thomas; Leidecker, Christianne; Groden, Christoph; Scharf, Johann; Henzler, Thomas

    2015-01-01

    To prospectively intra-individually compare image quality of a 3rd generation Dual-Source-CT (DSCT) spiral cranial CT (cCT) to a sequential 4-slice Multi-Slice-CT (MSCT) while maintaining identical intra-individual radiation dose levels. 35 patients, who had a non-contrast enhanced sequential cCT examination on a 4-slice MDCT within the past 12 months, underwent a spiral cCT scan on a 3rd generation DSCT. CTDIvol identical to initial 4-slice MDCT was applied. Data was reconstructed using filtered backward projection (FBP) and 3rd-generation iterative reconstruction (IR) algorithm at 5 different IR strength levels. Two neuroradiologists independently evaluated subjective image quality using a 4-point Likert-scale and objective image quality was assessed in white matter and nucleus caudatus with signal-to-noise ratios (SNR) being subsequently calculated. Subjective image quality of all spiral cCT datasets was rated significantly higher compared to the 4-slice MDCT sequential acquisitions (pspiral compared to sequential cCT datasets with mean SNR improvement of 61.65% (p*Bonferroni0.05spiral cCT with an advanced model IR technique significantly improves subjective and objective image quality compared to a standard sequential cCT acquisition acquired at identical dose levels.

  6. Variation of densitometry on computed tomography in COPD--influence of different software tools.

    Directory of Open Access Journals (Sweden)

    Mark O Wielpütz

    Full Text Available Quantitative multidetector computed tomography (MDCT as a potential biomarker is increasingly used for severity assessment of emphysema in chronic obstructive pulmonary disease (COPD. Aim of this study was to evaluate the user-independent measurement variability between five different fully-automatic densitometry software tools.MDCT and full-body plethysmography incl. forced expiratory volume in 1s and total lung capacity were available for 49 patients with advanced COPD (age = 64±9 years, forced expiratory volume in 1 s = 31±6% predicted. Measurement variation regarding lung volume, emphysema volume, emphysema index, and mean lung density was evaluated for two scientific and three commercially available lung densitometry software tools designed to analyze MDCT from different scanner types.One scientific tool and one commercial tool failed to process most or all datasets, respectively, and were excluded. One scientific and another commercial tool analyzed 49, the remaining commercial tool 30 datasets. Lung volume, emphysema volume, emphysema index and mean lung density were significantly different amongst these three tools (p<0.001. Limits of agreement for lung volume were [-0.195, -0.052 l], [-0.305, -0.131 l], and [-0.123, -0.052 l] with correlation coefficients of r = 1.00 each. Limits of agreement for emphysema index were [-6.2, 2.9%], [-27.0, 16.9%], and [-25.5, 18.8%], with r = 0.79 to 0.98. Correlation of lung volume with total lung capacity was good to excellent (r = 0.77 to 0.91, p<0.001, but segmented lung volume (6.7±1.3-6.8±1.3 l were significantly lower than total lung capacity (7.7±1.7 l, p<0.001.Technical incompatibilities hindered evaluation of two of five tools. The remaining three showed significant measurement variation for emphysema, hampering quantitative MDCT as a biomarker in COPD. Follow-up studies should currently use identical software, and standardization efforts should encompass software as

  7. Perfusion MDCT enables early detection of therapeutic response to antiangiogenic therapy.

    Science.gov (United States)

    Sabir, Adeel; Schor-Bardach, Rachel; Wilcox, Carol J; Rahmanuddin, Syed; Atkins, Michael B; Kruskal, Jonathan B; Signoretti, Sabina; Raptopoulos, Vassilios D; Goldberg, S Nahum

    2008-07-01

    The objective of our study was to determine whether perfusion CT can be used to detect early changes in therapeutic response to antiangiogenic therapy in an animal tumor model. Twenty-five rats implanted with R3230 mammary adenocarcinoma (diameter, 1.2-2.0 cm) randomly received 7.5 or 30 mg/kg of an antiangiogenic agent, sorafenib, by daily gavage for 4 (n = 4), 9 (n = 9), or 14 (n = 5) days. Seven untreated animals served as a control group. Perfusion MDCT was performed at days 0, 4, 9, and 14 with 0.4 mL of ioversol (350 mg/mL) and included four 5-mm slices covering the entire tumor volume. Changes in tumor growth were determined by volumetric analysis of CT data. Serial changes in tumor volume and blood flow were assessed and correlated with pathology findings. All control tumors grew larger (from 2.0 +/- 0.7 cm(3) at day 0 to 5.9 +/- 1.0 cm(3) at day 14), whereas all treated tumors shrank (from 2.5 +/- 1.1 to 2.1 +/- 1.0 cm(3)), with a statistically significant rate of growth or shrinkage in both groups (p histopathologic viability despite the fact that these tumors were shrinking in size from day 4 onward (day 4, 2.18 +/- 0.8 cm(3); day 9, 1.98 +/- 0.8 cm(3)). Perfusion MDCT can detect focal blood flow changes even when the tumor is shrinking, possibly indicating early reversal of tumor responsiveness to antiangiogenic therapy. Given that changes in tumor volume after antiangiogenic therapy do not necessarily correlate with true treatment response, physiologic imaging of tumor perfusion may be necessary.

  8. Comparison of neutral and positive enteral contrast media for MDCT enteroclysis

    International Nuclear Information System (INIS)

    Aiyappan, Senthil Kumar; Kalra, Naveen; Sandhu, Manavjit Singh; Kochhar, Rakesh; Wig, Jai Dev; Khandelwal, Niranjan

    2012-01-01

    Objective: To compare neutral and positive enteral contrast media for MDCT enteroclysis (MDCTE) in various small bowel diseases. Materials and methods: 40 patients with suspicion of small bowel diseases were divided randomly into two equal groups. In one group, water was used as neutral enteral contrast and in other group, 2% water soluble iodinated contrast was used as positive enteral contrast. All MDCTE were done on a 16-slice multidetector row CT unit. The findings of MDCTE were compared with the standards of reference. Results: There were 12 cases of abdominal tuberculosis (30%), 5 cases of bowel masses (12%), 4 cases of Crohn's disease (10%), 3 cases of small bowel adhesions (7%), 2 cases of midgut volvulus (5%), 2 cases of segmental enteritis (5%) and 12 of all cases (30%) were normal. There was no statistically significant difference between neutral and positive enteral contrast with regards to bowel distention, contrast reflux and evaluation of duodenum. Abnormal bowel wall enhancement was appreciated only with use of neutral enteral contrast (n = 12). Evaluation of ileocaecal junction was possible in all 20 patients (100%) with positive enteral contrast but in only 17 patients (85%) with neutral enteral contrast. Overall sensitivity and specificity of MDCTE with use of neutral contrast medium (100 and 88% respectively) was greater for evaluation of small bowel diseases, when compared to MDCTE using positive enteral contrast medium (92.8 and 83.3% respectively). Conclusions: Water is a good enteral contrast medium for MDCT enteroclysis examination and allows better evaluation of abnormal bowel wall enhancement. Ileocaecal junction evaluation is better with positive enteral contrast medium.

  9. Exogenous stimuli and circadian peak expiratory flow variation in allergic asthmatic children

    NARCIS (Netherlands)

    Meijer, G. G.; Postma, D. S.; van der Heide, S.; de Reus, D. M.; Roorda, R. J.; Koëter, G. H.; van Aalderen, W. M.

    1996-01-01

    The influence of exogenous factors in the home on the circadian variation of airway obstruction has not been fully assessed in children with asthma. The aim of the present study was to investigate the contribution of exogenous stimuli to the degree of peak expiratory flow (PEF) variability during 24

  10. Exogenous stimuli and circadian peak expiratory flow variation in allergic asthmatic children

    NARCIS (Netherlands)

    Postma, DS; VanderHeide, S; DeReus, DM; Koeter, GH; VanAalderen, WMC; Meijer, G.

    The influence of exogenous factors in the home on the circadian variation of airway obstruction has not been fully assessed in children with asthma. The aim of the present study was to investigate the contribution of exogenous stimuli to the degree of peak expiratory flow (PEF) variability during 24

  11. Prediction of bone strength by μCT and MDCT-based finite-element-models: How much spatial resolution is needed?

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Jan S., E-mail: jsb@tum.de [Department of Radiology, Technische Universität München, Munich (Germany); Department of Radiology, University of California, San Francisco, CA (United States); Max Planck Institute for Extraterrestrial Physics, Garching (Germany); Sidorenko, Irina [Max Planck Institute for Extraterrestrial Physics, Garching (Germany); Mueller, Dirk [Department of Radiology, Universität Köln (Germany); Baum, Thomas [Department of Radiology, Technische Universität München, Munich (Germany); Department of Radiology, University of California, San Francisco, CA (United States); Max Planck Institute for Extraterrestrial Physics, Garching (Germany); Issever, Ahi Sema [Department of Radiology, University of California, San Francisco, CA (United States); Department of Radiology, Charite, Berlin (Germany); Eckstein, Felix [Institute of Anatomy and Musculoskeletal Research, Paracelsus Medical University, Salzburg (Austria); Rummeny, Ernst J. [Department of Radiology, Technische Universität München, Munich (Germany); Link, Thomas M. [Department of Radiology, University of California, San Francisco, CA (United States); Raeth, Christoph W. [Max Planck Institute for Extraterrestrial Physics, Garching (Germany)

    2014-01-15

    Objectives: Finite-element-models (FEM) are a promising technology to predict bone strength and fracture risk. Usually, the highest spatial resolution technically available is used, but this requires excessive computation time and memory in numerical simulations of large volumes. Thus, FEM were compared at decreasing resolutions with respect to local strain distribution and prediction of failure load to (1) validate MDCT-based FEM and to (2) optimize spatial resolution to save computation time. Materials and methods: 20 cylindrical trabecular bone specimens (diameter 12 mm, length 15–20 mm) were harvested from elderly formalin-fixed human thoracic spines. All specimens were examined by micro-CT (isotropic resolution 30 μm) and whole-body multi-row-detector computed tomography (MDCT, 250 μm × 250 μm × 500 μm). The resolution of all datasets was lowered in eight steps to ∼2000 μm × 2000 μm × 500 μm and FEM were calculated at all resolutions. Failure load was determined by biomechanical testing. Probability density functions of local micro-strains were compared in all datasets and correlations between FEM-based and biomechanically measured failure loads were determined. Results: The distribution of local micro-strains was similar for micro-CT and MDCT at comparable resolutions and showed a shift toward higher average values with decreasing resolution, corresponding to the increasing apparent trabecular thickness. Small micro-strains (ε{sub eff} < 0.005) could be calculated down to 250 μm × 250 μm × 500 μm. Biomechanically determined failure load showed significant correlations with all FEM, up to r = 0.85 and did not significantly change with lower resolution but decreased with high thresholds, due to loss of trabecular connectivity. Conclusion: When choosing connectivity-preserving thresholds, both micro-CT- and MDCT-based finite-element-models well predicted failure load and still accurately revealed the distribution of local micro-strains in

  12. Prediction of bone strength by μCT and MDCT-based finite-element-models: How much spatial resolution is needed?

    International Nuclear Information System (INIS)

    Bauer, Jan S.; Sidorenko, Irina; Mueller, Dirk; Baum, Thomas; Issever, Ahi Sema; Eckstein, Felix; Rummeny, Ernst J.; Link, Thomas M.; Raeth, Christoph W.

    2014-01-01

    Objectives: Finite-element-models (FEM) are a promising technology to predict bone strength and fracture risk. Usually, the highest spatial resolution technically available is used, but this requires excessive computation time and memory in numerical simulations of large volumes. Thus, FEM were compared at decreasing resolutions with respect to local strain distribution and prediction of failure load to (1) validate MDCT-based FEM and to (2) optimize spatial resolution to save computation time. Materials and methods: 20 cylindrical trabecular bone specimens (diameter 12 mm, length 15–20 mm) were harvested from elderly formalin-fixed human thoracic spines. All specimens were examined by micro-CT (isotropic resolution 30 μm) and whole-body multi-row-detector computed tomography (MDCT, 250 μm × 250 μm × 500 μm). The resolution of all datasets was lowered in eight steps to ∼2000 μm × 2000 μm × 500 μm and FEM were calculated at all resolutions. Failure load was determined by biomechanical testing. Probability density functions of local micro-strains were compared in all datasets and correlations between FEM-based and biomechanically measured failure loads were determined. Results: The distribution of local micro-strains was similar for micro-CT and MDCT at comparable resolutions and showed a shift toward higher average values with decreasing resolution, corresponding to the increasing apparent trabecular thickness. Small micro-strains (ε eff < 0.005) could be calculated down to 250 μm × 250 μm × 500 μm. Biomechanically determined failure load showed significant correlations with all FEM, up to r = 0.85 and did not significantly change with lower resolution but decreased with high thresholds, due to loss of trabecular connectivity. Conclusion: When choosing connectivity-preserving thresholds, both micro-CT- and MDCT-based finite-element-models well predicted failure load and still accurately revealed the distribution of local micro-strains in spatial

  13. Approaches to reducing photon dose calculation errors near metal implants

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Jessie Y.; Followill, David S.; Howell, Rebecca M.; Mirkovic, Dragan; Kry, Stephen F., E-mail: sfkry@mdanderson.org [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, The University of Texas Health Science Center Houston, Houston, Texas 77030 (United States); Liu, Xinming [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, The University of Texas Health Science Center Houston, Houston, Texas 77030 (United States); Stingo, Francesco C. [Department of Biostatistics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, The University of Texas Health Science Center Houston, Houston, Texas 77030 (United States)

    2016-09-15

    Purpose: Dose calculation errors near metal implants are caused by limitations of the dose calculation algorithm in modeling tissue/metal interface effects as well as density assignment errors caused by imaging artifacts. The purpose of this study was to investigate two strategies for reducing dose calculation errors near metal implants: implementation of metal-based energy deposition kernels in the convolution/superposition (C/S) dose calculation method and use of metal artifact reduction methods for computed tomography (CT) imaging. Methods: Both error reduction strategies were investigated using a simple geometric slab phantom with a rectangular metal insert (composed of titanium or Cerrobend), as well as two anthropomorphic phantoms (one with spinal hardware and one with dental fillings), designed to mimic relevant clinical scenarios. To assess the dosimetric impact of metal kernels, the authors implemented titanium and silver kernels in a commercial collapsed cone C/S algorithm. To assess the impact of CT metal artifact reduction methods, the authors performed dose calculations using baseline imaging techniques (uncorrected 120 kVp imaging) and three commercial metal artifact reduction methods: Philips Healthcare’s O-MAR, GE Healthcare’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI with metal artifact reduction software (MARS) applied. For the simple geometric phantom, radiochromic film was used to measure dose upstream and downstream of metal inserts. For the anthropomorphic phantoms, ion chambers and radiochromic film were used to quantify the benefit of the error reduction strategies. Results: Metal kernels did not universally improve accuracy but rather resulted in better accuracy upstream of metal implants and decreased accuracy directly downstream. For the clinical cases (spinal hardware and dental fillings), metal kernels had very little impact on the dose calculation accuracy (<1.0%). Of the commercial CT artifact

  14. Approaches to reducing photon dose calculation errors near metal implants

    International Nuclear Information System (INIS)

    Huang, Jessie Y.; Followill, David S.; Howell, Rebecca M.; Mirkovic, Dragan; Kry, Stephen F.; Liu, Xinming; Stingo, Francesco C.

    2016-01-01

    Purpose: Dose calculation errors near metal implants are caused by limitations of the dose calculation algorithm in modeling tissue/metal interface effects as well as density assignment errors caused by imaging artifacts. The purpose of this study was to investigate two strategies for reducing dose calculation errors near metal implants: implementation of metal-based energy deposition kernels in the convolution/superposition (C/S) dose calculation method and use of metal artifact reduction methods for computed tomography (CT) imaging. Methods: Both error reduction strategies were investigated using a simple geometric slab phantom with a rectangular metal insert (composed of titanium or Cerrobend), as well as two anthropomorphic phantoms (one with spinal hardware and one with dental fillings), designed to mimic relevant clinical scenarios. To assess the dosimetric impact of metal kernels, the authors implemented titanium and silver kernels in a commercial collapsed cone C/S algorithm. To assess the impact of CT metal artifact reduction methods, the authors performed dose calculations using baseline imaging techniques (uncorrected 120 kVp imaging) and three commercial metal artifact reduction methods: Philips Healthcare’s O-MAR, GE Healthcare’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI with metal artifact reduction software (MARS) applied. For the simple geometric phantom, radiochromic film was used to measure dose upstream and downstream of metal inserts. For the anthropomorphic phantoms, ion chambers and radiochromic film were used to quantify the benefit of the error reduction strategies. Results: Metal kernels did not universally improve accuracy but rather resulted in better accuracy upstream of metal implants and decreased accuracy directly downstream. For the clinical cases (spinal hardware and dental fillings), metal kernels had very little impact on the dose calculation accuracy (<1.0%). Of the commercial CT artifact

  15. Treatment Planning for Pulsed Reduced Dose-Rate Radiotherapy in Helical Tomotherapy

    International Nuclear Information System (INIS)

    Rong Yi; Paliwal, Bhudatt; Howard, Steven P.; Welsh, James

    2011-01-01

    Purpose: Pulsed reduced dose-rate radiotherapy (PRDR) is a valuable method of reirradiation because of its potential to reduce late normal tissue toxicity while still yielding significant tumoricidal effect. A typical method using a conventional linear accelerator (linac) is to deliver a series of 20-cGy pulses separated by 3-min intervals to give an effective dose-rate of just under 7 cGy/min. Such a strategy is fraught with difficulties when attempted on a helical tomotherapy unit. We investigated various means to overcome this limitation. Methods and Materials: Phantom and patient cases were studied. Plans were generated with varying combinations of field width (FW), pitch, and modulation factor (MF) to administer 200 cGy per fraction to the planning target in eight subfractions, thereby mimicking the technique used on conventional linacs. Plans were compared using dose-volume histograms, homogeneity indices, conformation numbers, and treatment time. Plan delivery quality assurance was performed to assess deliverability. Results: It was observed that for helical tomotherapy, intrinsic limitations in leaf open time in the multileaf collimator deteriorate plan quality and deliverability substantially when attempting to deliver very low doses such as 20-40 cGy. The various permutations evaluated revealed that the combination of small FW (1.0 cm), small MF (1.3-1.5), and large pitch (∼0.86), along with the half-gantry-angle-blocked scheme, can generate clinically acceptable plans with acceptable delivery accuracy (±3%). Conclusion: Pulsed reduced dose-rate radiotherapy can be accurately delivered using helical tomotherapy for tumor reirradiation when the appropriate combination of FW, MF, and pitch is used.

  16. Respiratory System Mechanics During Low Versus High Positive End-Expiratory Pressure in Open Abdominal Surgery: A Substudy of PROVHILO Randomized Controlled Trial

    NARCIS (Netherlands)

    D'Antini, Davide; Huhle, Robert; Herrmann, Jacob; Sulemanji, Demet S.; Oto, Jun; Raimondo, Pasquale; Mirabella, Lucia; Hemmes, Sabrine N. T.; Schultz, Marcus J.; Pelosi, Paolo; Kaczka, David W.; Vidal Melo, Marcos Francisco; Gama de Abreu, Marcelo; Cinnella, Gilda

    2018-01-01

    In the 2014 PROtective Ventilation using HIgh versus LOw positive end-expiratory pressure (PROVHILO) trial, intraoperative low tidal volume ventilation with high positive end-expiratory pressure (PEEP = 12 cm H2O) and lung recruitment maneuvers did not decrease postoperative pulmonary complications

  17. The diagnostic value of direct CT arthrography using MDCT in the evaluation of acetabular labral tear: with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Yong-Chan; Kim, Jae Yoon [Chung-Ang University College of Medicine, Department of Orthopaedic Surgery, Seoul (Korea, Republic of); Choi, Jung-Ah; Lee, Guen Young; Kang, Heung Sik [Seoul National University Bundang Hospital, Departments of Radiology, Seoul National University College of Medicine, 166 Gumi-ro, Bundang-gu, Seongnam (Korea, Republic of); Lee, Young-Kyun; Koo, Kyung-Hoi [Seoul National University Bundang Hospital, Orthopaedic Surgery, Seoul National University College of Medicine, Seongnam (Korea, Republic of)

    2013-05-15

    The purpose of this study was first, to determine the sensitivity, specificity, and accuracy of MDCT arthrography (CTA) for the diagnosis of acetabular labral tear and sulcus; second, to correlate tear types using the Lage classification system on CTA compared with the arthroscopic classification; and third, to correlate CTA localization with arthroscopic localization. Direct CTA was performed using 16- or 64-slice MDCT in 126 hips (124 patients) who had chronic groin pain and positive impingement test. Images were reviewed and evaluated by two experienced musculoskeletal radiologists preoperatively. CTA findings were compared with arthroscopic findings in 58 hips (56 patients) under consensus by two orthopedic surgeons. Forty-one of the 58 hips were diagnosed as labral tears on CT arthrography. Forty-three of the 58 hips were shown to have a labral tear on arthroscopy. Sensitivity, specificity, and accuracy for detecting labral tear and sulcus by CTA were 90.7%, 86.7%, and 89.7%, and 93.8%, 97.6% and 96.6% respectively for observer 1, and 90.7% and 80.0%, 87.9% and 87.5%, 95.2%, and 93.1 % respectively for observer 2. Thirty-five out of 41 hips (85%) that were diagnosed with labral tear on CTA correlated substantially with arthroscopic Lage classification (kappa coefficient = 0.65). CTA and arthroscopic findings showed similar distribution patterns of the tears with most lesions located in antero- and postero-superior areas (p = 0.013). Direct CT arthrography using MDCT may be a useful diagnostic technique in the detection of acetabular labral tear. (orig.)

  18. Visual vs Fully Automatic Histogram-Based Assessment of Idiopathic Pulmonary Fibrosis (IPF) Progression Using Sequential Multidetector Computed Tomography (MDCT)

    Science.gov (United States)

    Colombi, Davide; Dinkel, Julien; Weinheimer, Oliver; Obermayer, Berenike; Buzan, Teodora; Nabers, Diana; Bauer, Claudia; Oltmanns, Ute; Palmowski, Karin; Herth, Felix; Kauczor, Hans Ulrich; Sverzellati, Nicola

    2015-01-01

    Objectives To describe changes over time in extent of idiopathic pulmonary fibrosis (IPF) at multidetector computed tomography (MDCT) assessed by semi-quantitative visual scores (VSs) and fully automatic histogram-based quantitative evaluation and to test the relationship between these two methods of quantification. Methods Forty IPF patients (median age: 70 y, interquartile: 62-75 years; M:F, 33:7) that underwent 2 MDCT at different time points with a median interval of 13 months (interquartile: 10-17 months) were retrospectively evaluated. In-house software YACTA quantified automatically lung density histogram (10th-90th percentile in 5th percentile steps). Longitudinal changes in VSs and in the percentiles of attenuation histogram were obtained in 20 untreated patients and 20 patients treated with pirfenidone. Pearson correlation analysis was used to test the relationship between VSs and selected percentiles. Results In follow-up MDCT, visual overall extent of parenchymal abnormalities (OE) increased in median by 5 %/year (interquartile: 0 %/y; +11 %/y). Substantial difference was found between treated and untreated patients in HU changes of the 40th and of the 80th percentiles of density histogram. Correlation analysis between VSs and selected percentiles showed higher correlation between the changes (Δ) in OE and Δ 40th percentile (r=0.69; phistogram analysis at one year follow-up of IPF patients, whether treated or untreated: Δ 40th percentile might reflect the change in overall extent of lung abnormalities, notably of ground-glass pattern; furthermore Δ 80th percentile might reveal the course of reticular opacities. PMID:26110421

  19. Pharmacologic Interventions to Improve Splanchnic Oxygenation During Ventilation with Positive End-Expiratory Pressure

    NARCIS (Netherlands)

    Fournell, A.; Scheeren, T. W. L.; Picker, O.; Schwarte, L. A.; Wolf, M; Bucher, HU; Rudin, M; VanHuffel, S; Wolf, U; Bruley, DF; Harrison, DK

    2012-01-01

    Mechanical ventilation with positive end-expiratory pressure (PEEP) is an indispensable tool in the management of respiratory failure to preserve or improve lung function and systemic oxygenation. However, PEEP per se may also, as has been shown in experimental animals, impair regional

  20. Dead space and slope indices from the expiratory carbon dioxide tension-volume curve

    NARCIS (Netherlands)

    A.H. Kars (Alice); J.M. Bogaard (Jan); Th. Stijnen (Theo); J. de Vries; A.F.M. Verbraak (Anton); C. Hilvering

    1997-01-01

    textabstractThe slope of phase 3 and three noninvasively determined dead space estimates derived from the expiratory carbon dioxide tension (PCO2) versus volume curve, including the Bohr dead space (VD,Bohr), the Fowler dead space (VD,Fowler) and pre-interface expirate

  1. SPIO-Enhanced MRI Findings of Well-Differentiated Hepatocellular Carcinomas: Correlation with MDCT Findings

    International Nuclear Information System (INIS)

    Kim, Seong Hyun; Lee, Won Jae; Lim, Hyo K.; Park, Cheol Keun

    2009-01-01

    This study was designed to assess superparamagnetic iron oxide (SPIO)-enhanced MRI findings of well-differentiated hepatocellular carcinomas (HCCs) correlated with their multidetector-row CT (MDCT) findings. Seventy-two patients with 84 pathologically proven well-differentiated HCCs underwent triple-phase MDCT and SPIO-enhanced MRI at a magnetic field strength of 1.5 Tesla (n = 49) and 3.0 Tesla (n = 23). Two radiologists in consensus retrospectively reviewed the CT and MR images for attenuation value and the signal intensity of each tumor. The proportion of hyperintense HCCs as depicted on SPIO-enhanced T2- or T2*-weighted images were compared in terms of tumor size ( 1 cm), five CT attenuation patterns based on arterial and equilibrium phases and magnetic field strength, by the use of univariate and multivariate analyses. Seventy-eight (93%) and 71 (85%) HCCs were identified by CT and on SPIO-enhanced T2- and T2*-weighted images, respectively. For the CT attenuation pattern, one (14%) of seven isodense-isodense, four (67%) of six hypodense- hypodense, four (80%) of five isodense-hypodense, 14 (88%) of 16 hyperdense- isodense and 48 (96%) of 50 hyperdense-hypodense HCCs were hyperintense (Cochran-Armitage test for trend, p 0.05). Most well-differentiated HCCs show hyperintensity on SPIOenhanced MRI, although the lesions show various CT attenuation patterns. The CT attenuation pattern is the main factor that affects the proportion of hyperintense well-differentiated HCCs as depicted on SPIO-enhanced MRI

  2. MDCT linear and volumetric analysis of adrenal glands: Normative data and multiparametric assessment

    International Nuclear Information System (INIS)

    Carsin-Vu, Aline; Mule, Sebastien; Janvier, Annaelle; Hoeffel, Christine; Oubaya, Nadia; Delemer, Brigitte; Soyer, Philippe

    2016-01-01

    To study linear and volumetric adrenal measurements, their reproducibility, and correlations between total adrenal volume (TAV) and adrenal micronodularity, age, gender, body mass index (BMI), visceral (VAAT) and subcutaneous adipose tissue volume (SAAT), presence of diabetes, chronic alcoholic abuse and chronic inflammatory disease (CID). We included 154 patients (M/F, 65/89; mean age, 57 years) undergoing abdominal multidetector row computed tomography (MDCT). Two radiologists prospectively independently performed adrenal linear and volumetric measurements with semi-automatic software. Inter-observer reliability was studied using inter-observer correlation coefficient (ICC). Relationships between TAV and associated factors were studied using bivariate and multivariable analysis. Mean TAV was 8.4 ± 2.7 cm 3 (3.3-18.7 cm 3 ). ICC was excellent for TAV (0.97; 95 % CI: 0.96-0.98) and moderate to good for linear measurements. TAV was significantly greater in men (p < 0.0001), alcoholics (p = 0.04), diabetics (p = 0.0003) and those with micronodular glands (p = 0.001). TAV was lower in CID patients (p = 0.0001). TAV correlated positively with VAAT (r = 0.53, p < 0.0001), BMI (r = 0.42, p < 0.0001), SAAT (r = 0.29, p = 0.0003) and age (r = 0.23, p = 0.005). Multivariable analysis revealed gender, micronodularity, diabetes, age and BMI as independent factors influencing TAV. Adrenal gland MDCT-based volumetric measurements are more reproducible than linear measurements. Gender, micronodularity, age, BMI and diabetes independently influence TAV. (orig.)

  3. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT

    Energy Technology Data Exchange (ETDEWEB)

    Gay, F.; Lasalle, S.; Neuenschwander, S.; Brisse, H.J. [Institut Curie, Imaging Department, Paris (France); Pavia, Y.; Pierrat, N. [Institut Curie, Medical Physics Department, Paris (France)

    2014-01-15

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. (orig.)

  4. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT

    International Nuclear Information System (INIS)

    Gay, F.; Lasalle, S.; Neuenschwander, S.; Brisse, H.J.; Pavia, Y.; Pierrat, N.

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. (orig.)

  5. Study on the method or reducing the operator's exposure dose from a C-Arm system

    International Nuclear Information System (INIS)

    Kim, Ki Sik; Song, Jong Nam; Kim, Seung Ok

    2016-01-01

    In this study, C-Arm equipment is being used as we intend to verify the exposure dose on the operator by the scattering rays during the operation of the C-Arm equipment and to provide an effective method of reducing the exposure dose. Exposure dose is less than the Over Tube method utilizes the C-arm equipment Under Tube the scheme, The result showed that the exposure dose on the operator decreased with a thicker shield, and as the operator moved away from the center line. Moreover, as the research time prolongated, the exposure dose increased, and among the three affixed location of the dosimeter, the most exposure dose was measured at gonadal, then followed by chest and thyroid. However, in consideration of the relationship between the operator and the patient, the distance cannot be increased infinitely and the research time cannot be decreased infinitely in order to reduce the exposure dose. Therefore, by changing the thickness of the radiation shield, the exposure dose on the operator was able to be reduced. If you are using a C-Arm equipment discomfort during surgery because the grounds that the procedure is neglected and close to the dose of radiation shielding made can only increase. Because a separate control room cannot be used for the C-Arm equipment due to its characteristic, the exposure dose on the operator needs to be reduced by reinforcing the shield through an appropriate thickness of radiation shield devices, such as apron, etc. during a treatment

  6. Depiction of normal gastrointestinal anatomy with MDCT: comparison of low- and high-attenuation oral contrast media.

    Science.gov (United States)

    Erturk, Sukru Mehmet; Mortelé, Koenraad J; Oliva, Maria-Raquel; Ichikawa, Tomoaki; Silverman, Stuart G; Cantisani, Vito; Pagliara, Elisa; Ros, Pablo R

    2008-04-01

    To compare low- and high-attenuation oral contrast media for depiction of normal gastrointestinal anatomy with multidetector-row computed tomography (MDCT). A prospective, randomized study of 90 consecutive patients without known or suspected gastrointestinal disease was conducted after the approval of our Institutional Review Board. All patients underwent IV contrast-enhanced abdominal and pelvic CT scans after oral administration of 900 ml of either low- or high-attenuation barium sulphate suspension. Using a five-point scale, two radiologists independently graded distention and wall visualization of stomach, duodenum, jejunum, and ileum. The degree of distention and wall visualization was compared using Mann-Whitney U-test. Duodenal, jejunal and ileal distention (pcontrast medium were significantly higher than those with high-attenuation barium sulphate preparation, for reader 1. Duodenal and jejunal wall visualization scores with low-attenuation contrast medium (pcontrast medium, for reader 2. Interobserver agreement was fair to good for both distention (kappa-range: 0.41-0.74) and wall visualization (kappa-range: 0.48-0.71). MDCT with low-attenuation contrast medium provides distention and wall visualization of the GI tract that is equal or better than high-attenuation contrast medium.

  7. Effect of pilates method on inspiratory and expiratory muscle strength in the elderly

    Directory of Open Access Journals (Sweden)

    Beatriz Mendes Tozim

    2018-03-01

    Full Text Available With aging, the respiratory muscle strength decreases and the pilates method is a technique that uses respiration as one of its principles. The present study has the aim of analyzing the influence of the pilates method on respiratory muscle strength in older women. For the evaluation of respiratory muscle strength (inspiratory and expiratory, manovacuometer was used. Thirty-one older women were divided into two groups: 14 participated in the pilates group and 17 in the control group. Participants of the pilates group performed 16 sessions of pilates method with an hour of training, twice week for eight weeks. The control group participated in four educational lectures for eight weeks. For statistical analysis, Shapiro-Wilk, ANOVA for repeated measures (p <0.05 and Cohen’s D index were performed. The results showed significant difference and the mean effect for the Cohen’s D index expiratory muscle strength of the pilates group when comparing before (69.71 ± 25.48 and after (85.23 ± 22.21 training (p<0.05 with an increase of 23%. The results of inspiratory muscle strength were not significant but presented an average effect for the Cohen’s D index for the pilates group before (69.71 ± 35.46 and after (88.00 ± 34.87 training, with an increase of 27%. The control group did not present significant differences for the variables evaluated. It could be concluded that the pilates method is effective in improving expiratory muscle strength and provides positive effects on the increase in inspiratory muscle strength.

  8. Peak expiratory flow variability, bronchial responsiveness, and susceptibility to ambient air pollution in adults

    NARCIS (Netherlands)

    Boezen, M; Schouten, Jan; Rijcken, B; Vonk, J; Gerritsen, J; Hoek, G; Brunekreef, B; Postma, D

    1998-01-01

    Bronchial hyperresponsiveness (BHR) and peak expiratory flow (PEF) variability are associated expressions of airway lability, yet probably reflect different underlying pathophysiologic mechanisms. We investigated whether both measures can be used interchangeably to identify subjects who are

  9. The diagnostic value of multiplanar reconstruction on MDCT colonography for the preoperative staging of colorectal cancer

    International Nuclear Information System (INIS)

    Jin, Kwang Nam; Kim, Se Hyung; Lee, Jae Young; Lee, Jeong Min; Han, Joon Koo; Choi, Byung Ihn; Shin, Kyung-Sook

    2006-01-01

    The purpose of this study was to determine whether multiplanar reconstruction (MPR) images can improve the accuracy of MDCT-based colorectal cancer preoperative staging by receiver-operating characteristic (ROC) analysis. Fifty-five patients with colorectal cancer underwent contrast-enhanced CT colonography using an 8- or 16-row scanner. Two separate interval reviews of the axial MDCT datasets with/without MPR images (coronal and sagittal) were performed independently by two radiologists blinded to both the colonoscopic and histopathologic results. At each review session, the radiologists were asked to determine the colorectal cancer TNM stage within the context of differentiating ≤T3 from T4, N0 from ≥N1 and M0 from M1 using a five-point confidence scale. The radiologists' performance for staging the colorectal cancer using axial CT datasets with/without MPR images was evaluated using ROC analysis. Sensitivities, specificities and interobserver agreement were assessed. When MPR images were added, significant improvement was achieved by both radiologists for differentiating N0 from ≥N1 in terms of both A Z (0.651 to 0.769; 0.573 to 0.713) and specificity (26.7 to 69.2%; 23.1 to 76.9%) (P 0.05), but a significant improvement in the specificity (70 to 90%; 80 to 92%) was achieved by one radiologist (P<0.05). In terms of the M staging, a significant improvement in the Az (0.844 to 0.996) was observed for the combined interpretation of the axial and MPR images by one radiologist (P<0.05). Furthermore, substantial or almost perfect interobserver agreement was achieved for all TNM stagings for the combined interpretations (κ=0.641-0.866), whereas only fair to substantial agreement was achieved for the axial images alone (κ=0.337-0.707). In conclusion, the combined interpretation of the axial and MPR MDCT images significantly improved the local staging of colorectal cancer compared with assessments based on axial images alone. (orig.)

  10. IMRT in a pregnant patient: how to reduce the fetal dose?

    DEFF Research Database (Denmark)

    Josipovic, Mirjana; Nyström, Håkan; Kjaer-Kristoffersen, Flemming

    2008-01-01

    dose distribution. The peripheral dose originating from the final IMRT plan was measured at distances reaching from the most proximal to the most distal fetal position, along the accelerator's longitudinal axis, using an anthropomorphic phantom extended with water-equivalent plastic. The measured...... was built and placed beneath the accelerator head, extending caudally from the field edge, to function as an extra collimator jaw. This shield reduced the fetal dose by a factor of 3.5. The peripheral dose components were also measured for simple rectangular fields and also here the collimator scatter...... was the greatest contributor to the peripheral dose. Therefore, the shielding used for the IMRT treatment of our patient could also be used when shielding in conventional radiotherapy. It is important for a radiation therapy department to be prepared for treatment of a pregnant patient to shield the fetus...

  11. Intra-patient comparison of reduced-dose model-based iterative reconstruction with standard-dose adaptive statistical iterative reconstruction in the CT diagnosis and follow-up of urolithiasis

    Energy Technology Data Exchange (ETDEWEB)

    Tenant, Sean; Pang, Chun Lap; Dissanayake, Prageeth [Peninsula Radiology Academy, Plymouth (United Kingdom); Vardhanabhuti, Varut [Plymouth University Peninsula Schools of Medicine and Dentistry, Plymouth (United Kingdom); University of Hong Kong, Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, Pokfulam (China); Stuckey, Colin; Gutteridge, Catherine [Plymouth Hospitals NHS Trust, Plymouth (United Kingdom); Hyde, Christopher [University of Exeter Medical School, St Luke' s Campus, Exeter (United Kingdom); Roobottom, Carl [Plymouth University Peninsula Schools of Medicine and Dentistry, Plymouth (United Kingdom); Plymouth Hospitals NHS Trust, Plymouth (United Kingdom)

    2017-10-15

    To evaluate the accuracy of reduced-dose CT scans reconstructed using a new generation of model-based iterative reconstruction (MBIR) in the imaging of urinary tract stone disease, compared with a standard-dose CT using 30% adaptive statistical iterative reconstruction. This single-institution prospective study recruited 125 patients presenting either with acute renal colic or for follow-up of known urinary tract stones. They underwent two immediately consecutive scans, one at standard dose settings and one at the lowest dose (highest noise index) the scanner would allow. The reduced-dose scans were reconstructed using both ASIR 30% and MBIR algorithms and reviewed independently by two radiologists. Objective and subjective image quality measures as well as diagnostic data were obtained. The reduced-dose MBIR scan was 100% concordant with the reference standard for the assessment of ureteric stones. It was extremely accurate at identifying calculi of 3 mm and above. The algorithm allowed a dose reduction of 58% without any loss of scan quality. A reduced-dose CT scan using MBIR is accurate in acute imaging for renal colic symptoms and for urolithiasis follow-up and allows a significant reduction in dose. (orig.)

  12. Use of model-based iterative reconstruction (MBIR) in reduced-dose CT for routine follow-up of patients with malignant lymphoma: dose savings, image quality and phantom study

    International Nuclear Information System (INIS)

    Herin, Edouard; Chiaradia, Melanie; Cavet, Madeleine; Deux, Jean-Francois; Rahmouni, Alain; Gardavaud, Francois; Beaussart, Pauline; Richard, Philippe; Haioun, Corinne; Itti, Emmanuel; Luciani, Alain

    2015-01-01

    To evaluate both in vivo and in phantom studies, dose reduction, and image quality of body CT reconstructed with model-based iterative reconstruction (MBIR), performed during patient follow-ups for lymphoma. This study included 40 patients (mean age 49 years) with lymphoma. All underwent reduced-dose CT during follow-up, reconstructed using MBIR or 50 % advanced statistical iterative reconstruction (ASIR). All had previously undergone a standard dose CT with filtered back projection (FBP) reconstruction. The volume CT dose index (CTDIvol), the density measures in liver, spleen, fat, air, and muscle, and the image quality (noise and signal to noise ratio, SNR) (ANOVA) observed using standard or reduced-dose CT were compared both in patients and a phantom study (Catphan 600) (Kruskal Wallis). The CTDIvol was decreased on reduced-dose body CT (4.06 mGy vs. 15.64 mGy p < 0.0001). SNR was higher in reduced-dose CT reconstructed with MBIR than in 50 % ASIR or than standard dose CT with FBP (patients, p ≤ 0.01; phantoms, p = 0.003). Low contrast detectability and spatial resolution in phantoms were not altered on MBIR-reconstructed CT (p ≥ 0.11). Reduced-dose CT with MBIR reconstruction can decrease radiation dose delivered to patients with lymphoma, while keeping an image quality similar to that obtained on standard-dose CT. (orig.)

  13. Use of model-based iterative reconstruction (MBIR) in reduced-dose CT for routine follow-up of patients with malignant lymphoma: dose savings, image quality and phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Herin, Edouard; Chiaradia, Melanie; Cavet, Madeleine; Deux, Jean-Francois; Rahmouni, Alain [AP-HP, Hopitaux Universitaires Henri Mondor, Imagerie Medicale, Creteil (France); Universite Paris Est Creteil, Faculte de Medecine, Creteil (France); Gardavaud, Francois; Beaussart, Pauline [AP-HP, Hopitaux Universitaires Henri Mondor, Imagerie Medicale, Creteil (France); Richard, Philippe [GE Healthcare France, Buc (France); Haioun, Corinne [Universite Paris Est Creteil, Faculte de Medecine, Creteil (France); AP-HP, Hopitaux Universitaires Henri Mondor, Hemopathies Lymphoides, Creteil (France); Itti, Emmanuel [Universite Paris Est Creteil, Faculte de Medecine, Creteil (France); AP-HP, Hopitaux Universitaires Henri Mondor, Medecine Nucleaire, Creteil (France); Luciani, Alain [AP-HP, Hopitaux Universitaires Henri Mondor, Imagerie Medicale, Creteil (France); Universite Paris Est Creteil, Faculte de Medecine, Creteil (France); INSERM Unite U 955, Creteil (France); AP-HP, Groupe Henri Mondor Albert Chenevier, Imagerie Medicale, CHU Henri Mondor, Creteil Cedex (France)

    2015-08-15

    To evaluate both in vivo and in phantom studies, dose reduction, and image quality of body CT reconstructed with model-based iterative reconstruction (MBIR), performed during patient follow-ups for lymphoma. This study included 40 patients (mean age 49 years) with lymphoma. All underwent reduced-dose CT during follow-up, reconstructed using MBIR or 50 % advanced statistical iterative reconstruction (ASIR). All had previously undergone a standard dose CT with filtered back projection (FBP) reconstruction. The volume CT dose index (CTDIvol), the density measures in liver, spleen, fat, air, and muscle, and the image quality (noise and signal to noise ratio, SNR) (ANOVA) observed using standard or reduced-dose CT were compared both in patients and a phantom study (Catphan 600) (Kruskal Wallis). The CTDIvol was decreased on reduced-dose body CT (4.06 mGy vs. 15.64 mGy p < 0.0001). SNR was higher in reduced-dose CT reconstructed with MBIR than in 50 % ASIR or than standard dose CT with FBP (patients, p ≤ 0.01; phantoms, p = 0.003). Low contrast detectability and spatial resolution in phantoms were not altered on MBIR-reconstructed CT (p ≥ 0.11). Reduced-dose CT with MBIR reconstruction can decrease radiation dose delivered to patients with lymphoma, while keeping an image quality similar to that obtained on standard-dose CT. (orig.)

  14. Evaluation of radiation doses delivered in different chest CT protocols

    International Nuclear Information System (INIS)

    Gorycki, Tomasz; Lasek, Iwona; Kamiński, Kamil; Studniarek, Michał

    2014-01-01

    There are differences in the reference diagnostic levels for the computed tomography (CT) of the chest as cited in different literature sources. The doses are expressed either in weighted CT dose index (CTDI VOL ) used to express the dose per slice, dose-length product (DLP), and effective dose (E). The purpose of this study was to assess the radiation dose used in Low Dose Computer Tomography (LDCT) of the chest in comparison with routine chest CT examinations as well as to compare doses delivered in low dose chest CT with chest X-ray doses. CTDI VOL and DLP doses were taken to analysis from routine CT chest examinations (64 MDCT TK LIGHT SPEED GE Medical System) performed in 202 adult patients with FBP reconstruction: 51 low dose, 106 helical, 20 angio CT, and 25 high resolution CT protocols, as well as 19 helical protocols with iterative ASIR reconstruction. The analysis of chest X-ray doses was made on the basis of reports from 44 examinations. Mean values of CTDI VOL and DLP were, respectively: 2.1 mGy and 85.1 mGy·cm, for low dose, 9.7 mGy and 392.3 mGy·cm for helical, 18.2 mGy and 813.9 mGy·cm for angio CT, 2.3 mGy and 64.4 mGy·cm for high resolution CT, 8.9 mGy. and 317.6 mGy·cm for helical ASIR protocols. Significantly lower CTDI VOL and DLP values were observed for low dose and high resolution CT versus the remaining CT protocols; doses delivered in CT ASIR protocols were also lower (80–81%). The ratio between medial doses in low dose CT and chest X-ray was 11.56. Radiation dose in extended chest LDCT with parameters allowing for identification of mediastinal structures and adrenal glands is still much lower than that in standard CT protocols. Effective doses predicted for LDCT may exceed those used in chest X-ray examinations by a factor of 4 to 12, depending on LDCT scan parameters. Our results, as well as results from other authors, suggest a possibility of reducing the dose by means of iterative reconstruction. Efforts towards further dose

  15. Lung MRI of invasive fungal infection at 3 Tesla: evaluation of five different pulse sequences and comparison with multidetector computed tomography (MDCT)

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Chenggong; Tan, Xiangliang; Li, Caixia; Wu, Yuankui; Hao, Peng; Xiong, Wei; Xu, Yikai [Southern Medical University, Department of Medical Imaging Center, Nanfang Hospital, Guangzhou, Guangdong (China); Wei, Qi; Feng, Ru; Xu, Jun [Southern Medical University, Department of Hematology, Nanfang Hospital, Guangzhou (China); Chan, Queenie [Philips Healthcare, New Territories (China)

    2014-09-18

    To evaluate the diagnostic performance of five MR sequences to detect pulmonary infectious lesions in patients with invasive fungal infection (IFI), using multidetector computed tomography (MDCT) as the reference standard. Thirty-four immunocompromised patients with suspected IFI underwent MDCT and MRI. The MR studies were performed using five pulse sequences at 3.0 T: T2-weighted turbo spin echo (TSE), short-tau inversion recovery (STIR), spectrally selective attenuated inversion recovery (SPAIR), T1-weighted high resolution isotropic volume excitation (e-THRIVE) and T1-weighted fast field echo (T1-FFE). The size, lesion-to-lung contrast ratio and the detectability of pulmonary lesions on MR images were assessed. Image quality and artefacts on different sequences were also rated. A total of 84 lesions including nodules (n = 44) and consolidation (n = 40) were present in 75 lobes. SPAIR and e-THRIVE images achieved high overall lesion-related sensitivities for the detection of pulmonary abnormalities (90.5 % and 86.9 %, respectively). STIR showed the highest lesion-to-lung contrast ratio for nodules (21.8) and consolidation (17.0), whereas TSE had the fewest physiological artefacts. MRI at 3.0 T can depict clinically significant pulmonary IFI abnormalities with high accuracy compared to MDCT. SPAIR and e-THRIVE are preferred sequences for the detection of infectious lesions of 5 mm and larger. (orig.)

  16. Contrast enhanced chest-MDCT in oncologic patients. Prospective evaluation of the prevalence of incidental pulmonary embolism and added value of thin reconstructions

    Energy Technology Data Exchange (ETDEWEB)

    Tresoldi, Silvia; Flor, Nicola [Azienda Ospedaliera San Paolo, Dipartimento di Radiologia Diagnostica ed Interventistica, Milano (Italy); Luciani, Andrea [Azienda Ospedaliera San Paolo, Oncologia, Dipartimento di Medicina, Milano (Italy); Lombardi, Maria Antonietta; Colombo, Bernardo [Universita degli Studi di Milano, Scuola di Specializzazione in Radiodiagnostica, Facolta di Medicina e Chirurgia, Milano (Italy); Cornalba, Gianpaolo [Azienda Ospedaliera San Paolo, Dipartimento di Radiologia Diagnostica ed Interventistica, Milano (Italy); Universita degli Studi di Milano, Dipartimento di Scienze della Salute, Milano (Italy)

    2015-11-15

    To prospectively assess prevalence/characteristics of clinically unsuspected pulmonary embolism (PE) in cancer patients undergoing follow-up chest MDCT and investigate MDCT protocol. We evaluated 1013 oncologic patients. MDCT images at 5 and 1.25 mm thickness were independently evaluated. Pulmonary artery opacification degree was assessed. Presence, level, and site of PE were reported. Type of malignancy and metastases were reported for PE-positive patients. After excluding 1.4 % (14/1013) of examinations due to inadequate vessel opacification, 999 patients (572 male; mean age:68 ± 12 years; range:26-93 years) entered the study. Prevalence of PE was 5 %. There was significant improvement in the sensitivity for both readers in the evaluation of 1.25 mm compared to 5 mm images (46-50 % to 82-92 %). 30 % (15/51) PE were not described by the radiologist in the prospectively issued report; 53 % (27/51) of PE were segmental, 72.5 % (37/51) unilateral. The right lower lobe was the most involved (59 %). 27 % patients had colon cancer, 18 % lung cancer. Among PE-positive patients (25 male; mean age 70 ± 10 years; range:44-87 years), 25 % (13/51) had lung cancer, 15 % (8/51) colon cancer. Thin reconstructions are essential for PE diagnosis, regardless of reader experience. Regarding oncologic patients, incidental PE diagnosis influences anticoagulation therapy. (orig.)

  17. Contrast enhanced chest-MDCT in oncologic patients. Prospective evaluation of the prevalence of incidental pulmonary embolism and added value of thin reconstructions

    International Nuclear Information System (INIS)

    Tresoldi, Silvia; Flor, Nicola; Luciani, Andrea; Lombardi, Maria Antonietta; Colombo, Bernardo; Cornalba, Gianpaolo

    2015-01-01

    To prospectively assess prevalence/characteristics of clinically unsuspected pulmonary embolism (PE) in cancer patients undergoing follow-up chest MDCT and investigate MDCT protocol. We evaluated 1013 oncologic patients. MDCT images at 5 and 1.25 mm thickness were independently evaluated. Pulmonary artery opacification degree was assessed. Presence, level, and site of PE were reported. Type of malignancy and metastases were reported for PE-positive patients. After excluding 1.4 % (14/1013) of examinations due to inadequate vessel opacification, 999 patients (572 male; mean age:68 ± 12 years; range:26-93 years) entered the study. Prevalence of PE was 5 %. There was significant improvement in the sensitivity for both readers in the evaluation of 1.25 mm compared to 5 mm images (46-50 % to 82-92 %). 30 % (15/51) PE were not described by the radiologist in the prospectively issued report; 53 % (27/51) of PE were segmental, 72.5 % (37/51) unilateral. The right lower lobe was the most involved (59 %). 27 % patients had colon cancer, 18 % lung cancer. Among PE-positive patients (25 male; mean age 70 ± 10 years; range:44-87 years), 25 % (13/51) had lung cancer, 15 % (8/51) colon cancer. Thin reconstructions are essential for PE diagnosis, regardless of reader experience. Regarding oncologic patients, incidental PE diagnosis influences anticoagulation therapy. (orig.)

  18. Seasonal variations in house dust mite influence the circadian peak expiratory flow amplitude

    NARCIS (Netherlands)

    Postma, DS; vanderHeide, S; deReus, DM; Koeter, GH; vanAalderen, WMC; Meijer, G.

    1996-01-01

    The aim of the study was to investigate whether seasonal differences in house dust mite (HDM) allergen exposure influence the circadian peak expiratory flow (PEF) amplitude in asthmatic children. Asthmatic children (n = 25) with a solitary allergy to HDM were studied in spring and in autumn. All

  19. Low pulmonary artery flush perfusion pressure combined with high positive end-expiratory pressure reduces oedema formation in isolated porcine lungs

    International Nuclear Information System (INIS)

    Schumann, Stefan; Schließmann, Stephan J; Wagner, Giskard; Goebel, Ulrich; Priebe, Hans-Joachim; Guttmann, Josef; Kirschbaum, Andreas

    2010-01-01

    Flush perfusion of the pulmonary artery with organ protection solution is a standard procedure before lung explantation. However, rapid flush perfusion may cause pulmonary oedema which is deleterious in the lung transplantation setting. In this study we tested the hypotheses that high pulmonary perfusion pressure contributes to the development of pulmonary oedema and positive end-expiratory pressure (PEEP) counteracts oedema formation. We expected oedema formation to increase weight and decrease compliance of the lungs on the basis of a decrease in alveolar volume as fluid replaces alveolar air spaces. The pulmonary artery of 28 isolated porcine lungs was perfused with a low-potassium dextrane solution at low (mean 27 mmHg) or high (mean 40 mmHg) pulmonary artery pressure (PAP) during mechanical ventilation at low (4 cmH 2 O) or high (8 cmH 2 O) PEEP, respectively. Following perfusion and storage, relative increases in lung weight were smaller (p < 0.05) during perfusion at low PAP (62 ± 32% and 42 ± 26%, respectively) compared to perfusion at high PAP (133 ± 54% and 87 ± 30%, respectively). Compared to all other PAP–PEEP combinations, increases in lung weight were smallest (44 ± 9% and 27 ± 12%, respectively), nonlinear intratidal lung compliance was largest (46% and 17% respectively, both p < 0.05) and lung histology showed least infiltration of mononuclear cells in the alveolar septa, and least alveolar destruction during the combination of low perfusion pressure and high PEEP. The findings suggest that oedema formation during pulmonary artery flush perfusion in isolated and ventilated lungs can be reduced by choosing low perfusion pressure and high PEEP. PAP–PEEP titration to minimize pulmonary oedema should be based on lung mechanics and PAP monitoring

  20. Effect of duration of contrast material injection on peak enhancement times and values of the aorta, main portal vein, and liver at dynamic MDCT with the dose of contrast medium tailored to patient weight

    International Nuclear Information System (INIS)

    Erturk, S.M.; Ichikawa, T.; Sou, H.; Tsukamoto, T.; Motosugi, U.; Araki, T.

    2008-01-01

    Aim: To investigate the effects of contrast material injection duration on peak enhancement times and attenuation values of the aorta, main portal vein, and liver at MDCT when the dose of contrast material is adjusted to patient weight. Material and methods: Seventy-five patients were randomly assigned to one of five groups, with durations of injection of 25, 30, 35, 40, or 45 s. All patients were injected with 2 ml/kg iodine (300 mg/ml). Attenuation values and peak enhancement times for the aorta, main portal vein, and liver were determined. The relationship between patient weight and enhancement times and values, the differences regarding peak enhancement times, and the relationship between injection duration and enhancement values were investigated using Pearson correlation, analysis of variance (ANOVA), and Spearman rank correlation, respectively. Results: No significant correlations were seen between patient weight and peak enhancement times or values. Mean peak enhancement times for the aorta, main portal vein, and liver were 9-11 s, 18-22 s, and 30-34 s, respectively (p > 0.05). The correlations between injection duration and peak enhancement values were significant and negative. Conclusions: Regardless of patient weight and injection duration, peak enhancement times of aorta, main portal vein and liver were approximately 10, 20, and 30 s, respectively. The enhancement values tended to be higher for shorter injection durations

  1. Association of High-Dose Ibuprofen Use, Lung Function Decline, and Long-Term Survival in Children with Cystic Fibrosis.

    Science.gov (United States)

    Konstan, Michael W; VanDevanter, Donald R; Sawicki, Gregory S; Pasta, David J; Foreman, Aimee J; Neiman, Evgueni A; Morgan, Wayne J

    2018-04-01

    Cystic fibrosis deaths result primarily from lung function loss, so chronic respiratory therapies, intended to preserve lung function, are cornerstones of cystic fibrosis care. Although treatment-associated reduction in rate of lung function loss should ultimately improve cystic fibrosis survival, no such relationship has been described for any chronic cystic fibrosis therapy. In part, this is because the ages of most rapid lung function decline-early adolescence-precede the median age of cystic fibrosis deaths by more than a decade. To study associations of high-dose ibuprofen treatment with the rate of forced expiratory volume in 1 second decline and mortality among children followed in the Epidemiologic Study of Cystic Fibrosis and subsequently in the U.S. Cystic Fibrosis Foundation Patient Registry. We performed a matched cohort study using data from Epidemiologic Study of Cystic Fibrosis. Exposure was defined as high-dose ibuprofen use reported at ≥80% of encounters over 2 years. Unexposed children were matched to exposed children 5:1 using propensity scores on the basis of demographic, clinical, and treatment covariates. The rate of decline of percent predicted forced expiratory volume in 1 second during the 2-year follow-up period was estimated by mixed-effects modeling with random slopes and intercepts. Survival over 16 follow-up years in the U.S. Cystic Fibrosis Foundation Patient Registry was compared between treatment groups by using proportional hazards modeling controlling for matching and covariates. We included 775 high-dose ibuprofen users and 3,665 nonusers who were well matched on demographic, clinical, and treatment variables. High-dose ibuprofen users declined on average 1.10 percent predicted forced expiratory volume in 1 second/yr (95% confidence interval; 0.51, 1.69) during the 2-year treatment period, whereas nonusers declined at a rate of 1.76% percent predicted forced expiratory volume in 1 second/yr (95% confidence interval; 1.48, 2

  2. Safety of reduced dose of mycophenolate mofetil combined with tacrolimus in living-donor liver transplantation

    Directory of Open Access Journals (Sweden)

    Hyeyoung Kim

    2014-09-01

    Full Text Available Background/AimsThe dose of mycophenolate mofetil (MMF has been reduced in Asia due to side effects associated with the conventional fixed dose of 2-3 g/day. We aimed to determine the pharmacokinetics of a reduced dose of MMF and to validate its feasibility in combination with tacrolimus in living-donor liver transplantation (LDLT.MethodsTwo sequential studies were performed in adult LDLT between October 2009 and 2011. First, we performed a prospective pharmacokinetic study in 15 recipients. We measured the area under the curve from 0 to 12 hours (AUC0-12 for mycophenolic acid at postoperative days 7 and 14, and we performed a protocol biopsy before discharge. Second, among 215 recipients, we reviewed 74 patients who were initially administered a reduced dose of MMF (1.0 g/day with tacrolimus (trough, 8-12 ng/mL during the first month, and 5-8 ng/mL thereafter, with a 1-year follow-up. We performed protocol biopsies at 2 weeks and 1 year post-LDLT.ResultsIn the first part of study, AUC0-12 was less than 30 mgh/L in 93.3% of cases. In the second, validating study, 41.9% of the recipients needed dose reduction or cessation due to side effects within the first year after LDLT. At 12 months post-LDLT, 17.6% of the recipients were administered a lower dose of MMF (0.5 g/day, and 16.2% needed permanent cessation due to side effects. The 1- and 12-month rejection-free survival rates were 98.6% and 97.3%, respectively.ConclusionsA reduced dose of MMF was associated with low blood levels compared to the existing recommended therapeutic range. However, reducing the dose of MMF combined with a low level of tacrolimus was feasible clinically, with an excellent short-term outcome in LDLT.

  3. Prospective ECG triggering reduces prosthetic heart valve-induced artefacts compared with retrospective ECG gating on 256-slice CT

    NARCIS (Netherlands)

    Symersky, P.; Habets, J.; Westers, P.; Mol, de B.A.J.M.; Prokop, M.; Budde, R.P.J.

    2012-01-01

    Objectives Multidetector computed tomography (MDCT) has diagnostic value for the evaluation of prosthetic heart valve (PHV) dysfunction but it is hampered by artefacts. We hypothesised that image acquisition using prospective triggering instead of retrospective gating would reduce artefacts related

  4. Pancreatic neuroendocrine tumour (PNET): Staging accuracy of MDCT and its diagnostic performance for the differentiation of PNET with uncommon CT findings from pancreatic adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hoon; Lee, Jeong Min; Han, Joon Koo; Choi, Byung-Ihn [Seoul National University Hospital, Department of Radiology, 101 Daehangno, Jongno-gu, Seoul (Korea, Republic of); Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul (Korea, Republic of); Eun, Hyo Won [Yonsei University College of Medicine, Department of Radiology, Severance Hospital, Seodaemun-ku, Seoul (Korea, Republic of); Kim, Young Jae [Soonchunhyang University Hospital, Department of Radiology, 657 Hannam-Dong, Youngsan-Ku, Seoul (Korea, Republic of)

    2016-05-15

    To investigate staging accuracy of multidetector CT (MDCT) for pancreatic neuroendocrine tumour (PNET) and diagnostic performance for differentiation of PNET from pancreatic adenocarcinoma. We included 109 patients with surgically proven PNET (NETG1 = 66, NETG2 = 31, NEC = 12) who underwent MDCT. Two reviewers assessed stage and presence of predefined CT findings. We analysed the relationship between CT findings and tumour grade. Using PNETs with uncommon findings, we also estimated the possibility of PNET or adenocarcinoma. Accuracy for T stage was 85-88 % and N-metastasis was 83-89 %. Common findings included well circumscribed, homogeneously enhanced, hypervascular mass, common in lower grade tumours (p < 0.05). Uncommon findings included ill-defined, heterogeneously enhanced, hypovascular mass and duct dilation, common in higher grade tumours (p < 0.05). Using 31 PNETs with uncommon findings, diagnostic performance for differentiation from adenocarcinoma was 0.760-0.806. Duct dilatation was an independent predictor for adenocarcinoma (Exp(B) = 4.569). PNETs with uncommon findings were associated with significantly worse survival versus PNET with common findings (62.7 vs. 95.7 months, p < 0.001). MDCT is useful for preoperative evaluation of PNET; it not only accurately depicts the tumour stage but also prediction of tumour grade, because uncommon findings were more common in higher grade tumours. (orig.)

  5. A study of a measure for reducing radiation dose in dental radiography for children

    International Nuclear Information System (INIS)

    Tateno, Hidemi

    1982-01-01

    For this investigation the author employed the stabilized TLD and measured the effect of doses on several organs (of children) using water and Mix-D phantom. Based upon this data, the author developed an exposure cone (of children) which was thought to be the best concrete method for reduction of absorbed doses for children who are most frequentry X-rayed and therefore most likely to reduced absorbed doses in a considerable amount. The major findings have been obtained concerning this cone compared with the standard cone as follows. 1. The full mouth 6-film examination showed the largest of the absorbed doses to be on skin, eyes and the thyroid gland. 2. For example, the dose on thyroid gland with a full mouth 6-film examination was 0.734R. 3. The dose on the gonad was less than 0.001R with every technique. 4. Using the developed exposure cone for children we have succeeded in reducing the amount of doses on these organs. In addition the image quality improved due to the reduction of scattered X-rays. 5. Using the developed exposure cone (for children) the risk of thyroid cancer can be reduced a level of 10 -6 to a level of 10 -7 as compared with the standard exposure cone. 6. Supposing that it is over the crystalline lens limits of dose-equivalent in a year at several times with full mouth 6-film examinations can be estimated which with standard cone was about three times, developed cone was about eighty-eight times in a year. (J.P.N.)

  6. Effects of computing parameters and measurement locations on the estimation of 3D NPS in non-stationary MDCT images.

    Science.gov (United States)

    Miéville, Frédéric A; Bolard, Gregory; Bulling, Shelley; Gudinchet, François; Bochud, François O; Verdun, François R

    2013-11-01

    The goal of this study was to investigate the impact of computing parameters and the location of volumes of interest (VOI) on the calculation of 3D noise power spectrum (NPS) in order to determine an optimal set of computing parameters and propose a robust method for evaluating the noise properties of imaging systems. Noise stationarity in noise volumes acquired with a water phantom on a 128-MDCT and a 320-MDCT scanner were analyzed in the spatial domain in order to define locally stationary VOIs. The influence of the computing parameters in the 3D NPS measurement: the sampling distances bx,y,z and the VOI lengths Lx,y,z, the number of VOIs NVOI and the structured noise were investigated to minimize measurement errors. The effect of the VOI locations on the NPS was also investigated. Results showed that the noise (standard deviation) varies more in the r-direction (phantom radius) than z-direction plane. A 25 × 25 × 40 mm(3) VOI associated with DFOV = 200 mm (Lx,y,z = 64, bx,y = 0.391 mm with 512 × 512 matrix) and a first-order detrending method to reduce structured noise led to an accurate NPS estimation. NPS estimated from off centered small VOIs had a directional dependency contrary to NPS obtained from large VOIs located in the center of the volume or from small VOIs located on a concentric circle. This showed that the VOI size and location play a major role in the determination of NPS when images are not stationary. This study emphasizes the need for consistent measurement methods to assess and compare image quality in CT. Copyright © 2012 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Realistic simulation of reduced-dose CT with noise modeling and sinogram synthesis using DICOM CT images

    International Nuclear Information System (INIS)

    Won Kim, Chang; Kim, Jong Hyo

    2014-01-01

    Purpose: Reducing the patient dose while maintaining the diagnostic image quality during CT exams is the subject of a growing number of studies, in which simulations of reduced-dose CT with patient data have been used as an effective technique when exploring the potential of various dose reduction techniques. Difficulties in accessing raw sinogram data, however, have restricted the use of this technique to a limited number of institutions. Here, we present a novel reduced-dose CT simulation technique which provides realistic low-dose images without the requirement of raw sinogram data. Methods: Two key characteristics of CT systems, the noise equivalent quanta (NEQ) and the algorithmic modulation transfer function (MTF), were measured for various combinations of object attenuation and tube currents by analyzing the noise power spectrum (NPS) of CT images obtained with a set of phantoms. Those measurements were used to develop a comprehensive CT noise model covering the reduced x-ray photon flux, object attenuation, system noise, and bow-tie filter, which was then employed to generate a simulated noise sinogram for the reduced-dose condition with the use of a synthetic sinogram generated from a reference CT image. The simulated noise sinogram was filtered with the algorithmic MTF and back-projected to create a noise CT image, which was then added to the reference CT image, finally providing a simulated reduced-dose CT image. The simulation performance was evaluated in terms of the degree of NPS similarity, the noise magnitude, the bow-tie filter effect, and the streak noise pattern at photon starvation sites with the set of phantom images. Results: The simulation results showed good agreement with actual low-dose CT images in terms of their visual appearance and in a quantitative evaluation test. The magnitude and shape of the NPS curves of the simulated low-dose images agreed well with those of real low-dose images, showing discrepancies of less than +/−3.2% in

  8. The diagnosis of old gravel aspiration in adults by MDCT: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mi Young; Lee, Ki Yeol; Seo, Bo Kyoung; Kim, Je Hyeong; Jung, Ki Hwan [Ansan Hospital, Korea University Medical Center, Ansan (Korea, Republic of)

    2008-03-15

    We report a case of old gravel aspiration in a 57-year-old man who had been accidentally buried in a field of construction for ten hours, three years prior. A chest radiograph showed peribronchial pneumonic infiltrates in the right lower lobe, with a proximal ovoid radiopaque endobronchial density at the trunchus basalis. These findings were more clearly visualized on the 64-channel multidetector CT (MDCT). Moreover, the patient recovered from his condition, following a bronchoscopic retrieval. However, the patient had persistent bronchiectasis of the right lower lobe on a subsequent follow-up chest radiograph, one month later.

  9. Central venous device-related thrombosis as imaged with MDCT in oncologic patients: prevalence and findings

    International Nuclear Information System (INIS)

    Catalano, Orlando; Castelguidone, Elisabetta de Lutio di; Granata, Vincenza; D'Errico, Adolfo Gallipoli; Sandomenico, Claudia; Petrillo, Mario; Aprea, Pasquale

    2011-01-01

    Background: Venous thrombosis is a common occurrence in cancer patients, developing spontaneously or in combination with indwelling central venous devices (CVD). Purpose: To analyze the multidetector CT (MDCT) prevalence, appearance, and significance of catheter related thoracic venous thrombosis in oncologic patients and to determine the percentage of thrombi identified in the original reports. Material and Methods: Five hundred consecutive patients were considered. Inclusion criteria were: presence of a CVD; availability of a contrast-enhanced MDCT; and cancer history. Exclusion criteria were: direct tumor compression/infiltration of the veins; poor image quality; device tip not in the scanned volume; and missing clinical data. Seventeen (3.5%) out of the final 481 patients had a diagnosis of venous thrombosis. Results: Factors showing the highest correlation with thrombosis included peripherally-inserted CVD, right brachiocephalic vein tip location, patient performance status 3, metastatic stage disease, ongoing chemotherapy, and longstanding CVD. The highest prevalence was in patients with lymphoma, lung carcinoma, melanoma, and gynecologic malignancies. Eleven out of 17 cases had not been identified in the original report. Conclusion: CVD-related thrombosis is not uncommon in cancer patients and can also be observed in outpatients with a good performance status and a non-metastatic disease. Thrombi can be very tiny. Radiologists should be aware of the possibility to identify (or overlook) small thrombi

  10. Osteoporosis imaging: effects of bone preservation on MDCT-based trabecular bone microstructure parameters and finite element models

    International Nuclear Information System (INIS)

    Baum, Thomas; Grande Garcia, Eduardo; Burgkart, Rainer; Gordijenko, Olga; Liebl, Hans; Jungmann, Pia M.; Gruber, Michael; Zahel, Tina; Rummeny, Ernst J.; Waldt, Simone; Bauer, Jan S.

    2015-01-01

    Osteoporosis is defined as a skeletal disorder characterized by compromised bone strength due to a reduction of bone mass and deterioration of bone microstructure predisposing an individual to an increased risk of fracture. Trabecular bone microstructure analysis and finite element models (FEM) have shown to improve the prediction of bone strength beyond bone mineral density (BMD) measurements. These computational methods have been developed and validated in specimens preserved in formalin solution or by freezing. However, little is known about the effects of preservation on trabecular bone microstructure and FEM. The purpose of this observational study was to investigate the effects of preservation on trabecular bone microstructure and FEM in human vertebrae. Four thoracic vertebrae were harvested from each of three fresh human cadavers (n = 12). Multi-detector computed tomography (MDCT) images were obtained at baseline, 3 and 6 month follow-up. In the intervals between MDCT imaging, two vertebrae from each donor were formalin-fixed and frozen, respectively. BMD, trabecular bone microstructure parameters (histomorphometry and fractal dimension), and FEM-based apparent compressive modulus (ACM) were determined in the MDCT images and validated by mechanical testing to failure of the vertebrae after 6 months. Changes of BMD, trabecular bone microstructure parameters, and FEM-based ACM in formalin-fixed and frozen vertebrae over 6 months ranged between 1.0–5.6 % and 1.3–6.1 %, respectively, and were not statistically significant (p > 0.05). BMD, trabecular bone microstructure parameters, and FEM-based ACM as assessed at baseline, 3 and 6 month follow-up correlated significantly with mechanically determined failure load (r = 0.89–0.99; p < 0.05). The correlation coefficients r were not significantly different for the two preservation methods (p > 0.05). Formalin fixation and freezing up to six months showed no significant effects on trabecular bone microstructure

  11. Neglectable benefit of searching for incidental findings in the Dutch-Belgian lung cancer screening trial (NELSON) using low-dose multidetector CT

    International Nuclear Information System (INIS)

    Wiel, J.C.M. van de; Wang, Y.; Xu, D.M.; Zaag-Loonen, H.J. van der; Jagt, E.J. van der; Oudkerk, M.; Klaveren, R.J. van

    2007-01-01

    The purpose of this study was to prospectively determine the frequency and spectrum of incidental findings (IFs) and their clinical implications in a high risk population for lung cancer undergoing low-dose multidetector computed tomography (MDCT) screening for lung cancer. Scans of 1,929 participants were evaluated for lung lesions and IFs by two radiologists. IFs were categorised as not clinically relevant or possibly clinically relevant. Findings were considered possibly clinically relevant if they could require further evaluation or could have substantial clinical implications. All possibly clinically relevant IFs were reviewed by a third radiologist, who determined its clinical relevance. Of all 1,929 participants, 1,410 (73%) had not clinically relevant IFs and 163 (8%) had possibly clinically relevant IFs of which 129 (79%) were indeed considered clinically relevant. Additional imaging was performed mainly by ultrasound (112 of 118, 96%). All but one lesion were concluded to be benign, mostly cysts (n = 115, 80%). Only 21 (1%) participants had findings with clinical implications. In one participant a malignancy was found, yet without any clinical benefit since no curative treatment was possible. Based on our results, we advise against systematically searching for and reporting of IFs in lung cancer screening studies using low-dose MDCT. (orig.)

  12. Whole tumour first-pass perfusion using a low-dose method with 64-section multidetector row computed tomography in oesophageal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Chen Tianwu; Yang Zhigang; Dong Zhihui; Li Yuan; Yao Jin; Wang Qiling; Qian Lingling

    2011-01-01

    Purpose: To propose a low-dose method at tube current-time product of 50 mAs for whole tumour first-pass perfusion of oesophageal squamous cell carcinoma using 64-section multidetector row computed tomography (MDCT), and to assess the original image quality and accuracy of perfusion parameters. Materials and methods: Fifty-nine consecutive patients with confirmed oesophageal squamous cell carcinomas were enrolled into our study, and underwent whole tumour first-pass perfusion scan with 64-section MDCT at 50 mAs. Image data were statistically reviewed focusing on original image quality demonstrated by image-quality scores and signal-to-noise (S/N) ratios; and perfusion parameters including perfusion (PF, in ml/min/ml), peak enhanced density (PED, in HU), time to peak (TTP, in seconds) and blood volume (BV, in ml/100 g) for the tumour. To test the interobserver agreement of perfusion measurements, perfusion analyses were repeatedly performed. Results: Original image-quality scores were 4.71 ± 0.49 whereas S/N ratios were 5.21 ± 2.05, and the scores were correlated with the S/N ratios (r = 0.465, p < 0.0001). Mean values for PF, PED, TTP and BV of the tumour were 33.27 ± 24.15 ml/min/ml, 24.06 ± 9.87 HU, 29.42 ± 8.61 s, and 12.45 ± 12.22 ml/100 g, respectively. Intraclass correlation coefficient between the replicated measurements of each perfusion parameter was greater than 0.99, and mean difference of the replicated measurements of each parameter was close to zero. Conclusion: Whole tumour first-pass perfusion with 64-section MDCT at low-dose radiation could be reproducible to assess microcirculation in oesophageal squamous cell carcinoma without compromising subjective original image quality of the tumour.

  13. A method to reduce patient's eye lens dose in neuro-interventional radiology procedures

    International Nuclear Information System (INIS)

    Safari, M.J.; Wong, J.H.D.; Kadir, K.A.A.; Sani, F.M.; Ng, K.H.

    2016-01-01

    Complex and prolonged neuro-interventional radiology procedures using the biplane angiography system increase the patient's risk of radiation-induced cataract. Physical collimation is the most effective way of reducing the radiation dose to the patient's eye lens, but in instances where collimation is not possible, an attenuator may be useful in protecting the eyes. In this study, an eye lens protector was designed and fabricated to reduce the radiation dose to the patients’ eye lens during neuro-interventional procedures. The eye protector was characterised before being tested on its effectiveness in a simulated aneurysm procedure on an anthropomorphic phantom. Effects on the automatic dose rate control (ADRC) and image quality are also evaluated. The eye protector reduced the radiation dose by up to 62.1% at the eye lens. The eye protector is faintly visible in the fluoroscopy images and increased the tube current by a maximum of 3.7%. It is completely invisible in the acquisition mode and does not interfere with the clinical procedure. The eye protector placed within the radiation field of view was able to reduce the radiation dose to the eye lens by direct radiation beam of the lateral x-ray tube with minimal effect on the ADRC system. - Highlights: • The eye protector can considerably reduce the patient's eye lens dose during neuro-interventional procedures. • This protector does not significantly perturb the fluoroscopy image and was completely invisible on the acquisition image due to image subtraction. • The eye protector does not significantly change the exposure parameters (kV and mAs).

  14. Abdominal vascular and visceral parenchymal contrast enhancement in MDCT: Effects of injection duration

    Energy Technology Data Exchange (ETDEWEB)

    Tsuge, Yusuke, E-mail: tsugeu@cup.ocn.ne.jp [Department of Radiology, Kizawa Memorial Hospital, 590 Kobityo Shimokobi, Minokamo City, Gifu 505-8503 (Japan); Kanematsu, Masayuki [Department of Radiology, Gifu University Hospital, Gifu (Japan); Department of Radiology Services, Gifu University Hospital, Gifu (Japan); Goshima, Satoshi; Kondo, Hiroshi [Department of Radiology, Gifu University Hospital, Gifu (Japan); Yokoyama, Ryujiro; Miyoshi, Toshiharu [Department of Radiology Services, Gifu University Hospital, Gifu (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka (Japan); Moriyama, Noriyuki [Research Center for Cancer Prevention and Screening, National Cancer Center Hospital, Tsukiji (Japan); Bae, Kyongtae T. [Radiology and Biomedical Engineering, University of Pittsburgh, Pittsburgh, PA (United States)

    2011-11-15

    Purpose: To evaluate and compare the effect of short and long injection durations on aortic, pancreatic and hepatic enhancement in abdominal MDCT. Methods and materials: Triphasic contrast-enhanced CT images (16-MDCT, 1.25-mm collimation, 5-mm thickness, 6.1-s acquisition time for each phase) were obtained with 2 mL/kg injection of 300 mgI/mL iodine contrast material in 116 patients. Patients were prospectively randomized into two groups: one receiving contrast medium for 25-s injection duration and the other for 35-s injection duration. In both groups, triphasic scans were initiated 5, 15, and 40 s after the completion of contrast injection for the first, second and third phases, respectively. CT values (HU) in the abdominal aorta, liver, spleen, pancreas, splenic and superior mesenteric arteries, and veins (splenic, superior mesenteric, portal, and hepatic) were measured. Quantitative and qualitative analysis for the degree of contrast enhancement between the two groups in various organs was compared at each scan phase. Results: The aortic and arterial enhancements in the first-phase scan were higher for the 25-s group than those of the 35-s group (P < .001). Hepatic enhancement was higher for the 35-s group in the first (P < .001) and second (P < .01) phases, but no difference in the third-phase. No difference was found between the groups for the pancreatic enhancement at any phases. Qualitative results were in good agreement with quantitative results. Conclusion: Contrast administration with shorter injection duration increased peak aortic and arterial enhancement and contributed to improvement in the quality of CT angiograms, but for the solid abdominal organs 35-s protocol is recommended.

  15. MO-F-CAMPUS-I-03: GPU Accelerated Monte Carlo Technique for Fast Concurrent Image and Dose Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Becchetti, M; Tian, X; Segars, P; Samei, E [Clinical Imaging Physics Group, Department of Radiology, Duke University Me, Durham, NC (United States)

    2015-06-15

    Purpose: To develop an accurate and fast Monte Carlo (MC) method of simulating CT that is capable of correlating dose with image quality using voxelized phantoms. Methods: A realistic voxelized phantom based on patient CT data, XCAT, was used with a GPU accelerated MC code for helical MDCT. Simulations were done with both uniform density organs and with textured organs. The organ doses were validated using previous experimentally validated simulations of the same phantom under the same conditions. Images acquired by tracking photons through the phantom with MC require lengthy computation times due to the large number of photon histories necessary for accurate representation of noise. A substantial speed up of the process was attained by using a low number of photon histories with kernel denoising of the projections from the scattered photons. These FBP reconstructed images were validated against those that were acquired in simulations using many photon histories by ensuring a minimal normalized root mean square error. Results: Organ doses simulated in the XCAT phantom are within 10% of the reference values. Corresponding images attained using projection kernel smoothing were attained with 3 orders of magnitude less computation time compared to a reference simulation using many photon histories. Conclusion: Combining GPU acceleration with kernel denoising of scattered photon projections in MC simulations allows organ dose and corresponding image quality to be attained with reasonable accuracy and substantially reduced computation time than is possible with standard simulation approaches.

  16. MO-F-CAMPUS-I-03: GPU Accelerated Monte Carlo Technique for Fast Concurrent Image and Dose Simulation

    International Nuclear Information System (INIS)

    Becchetti, M; Tian, X; Segars, P; Samei, E

    2015-01-01

    Purpose: To develop an accurate and fast Monte Carlo (MC) method of simulating CT that is capable of correlating dose with image quality using voxelized phantoms. Methods: A realistic voxelized phantom based on patient CT data, XCAT, was used with a GPU accelerated MC code for helical MDCT. Simulations were done with both uniform density organs and with textured organs. The organ doses were validated using previous experimentally validated simulations of the same phantom under the same conditions. Images acquired by tracking photons through the phantom with MC require lengthy computation times due to the large number of photon histories necessary for accurate representation of noise. A substantial speed up of the process was attained by using a low number of photon histories with kernel denoising of the projections from the scattered photons. These FBP reconstructed images were validated against those that were acquired in simulations using many photon histories by ensuring a minimal normalized root mean square error. Results: Organ doses simulated in the XCAT phantom are within 10% of the reference values. Corresponding images attained using projection kernel smoothing were attained with 3 orders of magnitude less computation time compared to a reference simulation using many photon histories. Conclusion: Combining GPU acceleration with kernel denoising of scattered photon projections in MC simulations allows organ dose and corresponding image quality to be attained with reasonable accuracy and substantially reduced computation time than is possible with standard simulation approaches

  17. Aortic and hepatic enhancement at multidetector CT: Evaluation of optimal iodine dose determined by lean body weight

    International Nuclear Information System (INIS)

    Kondo, Hiroshi; Kanematsu, Masayuki; Goshima, Satoshi; Watanabe, Haruo; Onozuka, Minoru; Moriyama, Noriyuki; Bae, Kyongtae T.

    2011-01-01

    Purpose: To determine the optimal iodine dose for aortic and hepatic enhancement at MDCT by comparing lean body weight (LBW) with total body weight (TBW). Materials and methods: This study was approved by our institutional review committee. One hundred and thirty-six patients were randomized into four groups: 550, 650, 750 mg iodine/(kg of LBW) and 600 mgI/(kg of TBW). The aortic and hepatic contrast enhancements (ΔHUs) during the portal venous-phase and variances of ΔHUs were compared. Results: Mean ΔHUs for 550, 650, 750 mgI/kg LBW and 600 mgI/kg TBW were: 95.1, 109.9, 122.4, and 131.2 HU, respectively, for the aorta. For the liver, 43.1, 55.4, 60.8, and 63.5 HU. Mean ΔHUs increased with iodine dose per kg LBW (p < 0.01), but no significant difference between 750 mgI/kg LBW and 600 mgI/kg TBW groups. Hepatic enhancement increased by ≥50 HU in 94% of patients with 750 mg/kg LBW. Variance of hepatic enhancement was marginally greater in the 600 mgI/kg TBW than in the 550 and 750 mgI/kg LBW. Conclusion: Hepatic enhancement variation was reduced with iodine doses based on LBW. Iodine dose of 750 mg iodine/kg LBW was appropriate to achieve hepatic enhancement ≥50 HU in 94% of patients.

  18. Aortic and hepatic enhancement at multidetector CT: evaluation of optimal iodine dose determined by lean body weight.

    Science.gov (United States)

    Kondo, Hiroshi; Kanematsu, Masayuki; Goshima, Satoshi; Watanabe, Haruo; Onozuka, Minoru; Moriyama, Noriyuki; Bae, Kyongtae T

    2011-12-01

    To determine the optimal iodine dose for aortic and hepatic enhancement at MDCT by comparing lean body weight (LBW) with total body weight (TBW). This study was approved by our institutional review committee. One hundred and thirty-six patients were randomized into four groups: 550, 650, 750 mg iodine/(kg of LBW) and 600 mgI/(kg of TBW). The aortic and hepatic contrast enhancements (Δ HUs) during the portal venous-phase and variances of ΔHUs were compared. Mean ΔHUs for 550, 650, 750 mgI/kg LBW and 600 mgI/kg TBW were: 95.1, 109.9, 122.4, and 131.2HU, respectively, for the aorta. For the liver, 43.1, 55.4, 60.8, and 63.5 HU. Mean Δ HUs increased with iodine dose per kg LBW (p<0.01), but no significant difference between 750 mgI/kg LBW and 600 mgI/kg TBW groups. Hepatic enhancement increased by ≥50 HU in 94% of patients with 750 mg/kg LBW. Variance of hepatic enhancement was marginally greater in the 600 mgI/kg TBW than in the 550 and 750 mgI/kg LBW. Hepatic enhancement variation was reduced with iodine doses based on LBW. Iodine dose of 750 mg iodine/kg LBW was appropriate to achieve hepatic enhancement≥50 HU in 94% of patients. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  19. MDCT diagnostic work-up of patients with subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Phanis, S.; Nikolopoulos, P.; Veliou, K.; Tsampoulas, C.; Efremidis, S.

    2006-01-01

    haemorrhage, performed in the new MDCT Computed Tomographs (16 Detectors), is a fast, minimally invasive, well tolerated, and a diagnostic method gradually gaining international recognition by radiologists as well as by clinical doctors, especially as the experience of radiologists in the method is increasing. Digital Subtraction Angiography still remains the Gold Standard method of examination, the trend though appears to be in favor for MDCT Angiography. We are anxiously awaiting for the primary results from the newest 64 Detector and 256 Detector Computed Tomographs

  20. Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway.

    Directory of Open Access Journals (Sweden)

    Samantha Torres Grams

    Full Text Available Maximal Inspiratory Pressure (MIP is considered an effective method to estimate strength of inspiratory muscles, but still leads to false positive diagnosis. Although MIP assessment with unidirectional expiratory valve method has been used in patients undergoing mechanical ventilation, no previous studies investigated the application of this method in subjects without artificial airway.This study aimed to compare the MIP values assessed by standard method (MIPsta and by unidirectional expiratory valve method (MIPuni in subjects with spontaneous breathing without artificial airway. MIPuni reproducibility was also evaluated.This was a crossover design study, and 31 subjects performed MIPsta and MIPuni in a random order. MIPsta measured MIP maintaining negative pressure for at least one second after forceful expiration. MIPuni evaluated MIP using a unidirectional expiratory valve attached to a face mask and was conducted by two evaluators (A and B at two moments (Tests 1 and 2 to determine interobserver and intraobserver reproducibility of MIP values. Intraclass correlation coefficient (ICC[2,1] was used to determine intraobserver and interobserver reproducibility.The mean values for MIPuni were 14.3% higher (-117.3 ± 24.8 cmH2O than the mean values for MIPsta (-102.5 ± 23.9 cmH2O (p<0.001. Interobserver reproducibility assessment showed very high correlation for Test 1 (ICC[2,1] = 0.91, and high correlation for Test 2 (ICC[2,1] = 0.88. The assessment of the intraobserver reproducibility showed high correlation for evaluator A (ICC[2,1] = 0.86 and evaluator B (ICC[2,1] = 0.77.MIPuni presented higher values when compared with MIPsta and proved to be reproducible in subjects with spontaneous breathing without artificial airway.

  1. Effect of simultaneous application of postural techniques and expiratory muscle strength training on the enhancement of the swallowing function of patients with dysphagia caused by parkinson?s disease

    OpenAIRE

    Byeon, Haewon

    2016-01-01

    [Purpose] This study aimed to investigate the effect of simultaneous application of postural techniques and expiratory muscle strength training on the enhancement of the swallowing function of patients with dysphagia caused by Parkinson?s disease. [Subjects and Methods] The subjects of this study were 18 patients who received simultaneous application of postural techniques and expiratory muscle strength training and 15 patients who received expiratory muscle strength training only. Postural t...

  2. Quality control of diagnostic radiology to reduce absorbed dose of patients in Iran

    International Nuclear Information System (INIS)

    Aghahadi, Bahman.

    1996-01-01

    In order to reduce absorbed dose, to increase the image quality and to reduce the numbers of rejected films various quality control parameters were applied to X ray machines. These parameter are Kilo Volt peak, Milli Ampere, Exposure Time Focal Film Distance, Inherent Filters, Additional Filters Half Value Layer, Processor Condition, Cassettes. To evaluate and to apply these parameters in diagnostic radiological centers, ten hospitals were selected and a total number of 12 X ray machines were kept under quality control program. Considering different kinds of diagnostic radiology examination and to compare the dose before and after implementation of a quality control program, two kinds of examinations include in chest and abdomen examinations were considered. For each X ray machine, ten patients and for all selected centers, 120 patients were selected for chest examination and 120 patients for abdomen examinations; before and after implementation of quality control program, a total of 480 patients were selected randomly to be controlled. Base on different examinations carried out, it was concluded that both exposure conditions and general situations in radiological centers were not acceptable. The dosimetry results show that the average ski dose for chest and abdomen examinations were 0.28 m Gy and 4.23 Gy respectively. Before implementation of quality control step to reduce the surface skin dose, quality control parameters were applied and the exposure conditions were imposed. On average the absorbed doses for chest and abdomen examination were decreased to 79% and 61% respectively after the implementation of the program. From dose reduction point of view, the results of a part of this project which made by co-operation of International Atomic Energy Agency showed that Iran acquired the first grade for chest examination and second grade for abdomen examination. Base on the results obtained, the number of patients under chest and abdomen examination were 4041588 and

  3. Ovarian and endocrine responses in tropical sheep treated with reduced doses of cloprostenol.

    Science.gov (United States)

    Contreras-Solis, Ignacio; Vasquez, B; Diaz, T; Letelier, C; Lopez-Sebastian, A; Gonzalez-Bulnes, A

    2009-09-01

    The present study aimed to assess the efficacy of reduced doses of cloprostenol for synchronizing estrus and ovulation in hair sheep. With the aim to evaluate the luteolytic activity of reduced cloprostenol doses, a first experiment was performed using a relatively large (group H: 126 microg; n=8), medium (group M: 68.25 microg; n=6) and small (group L: 38.5 microg; n=6) cloprostenol dose. Luteolysis was assessed at Days 3 and 6 after injection (Day 0) by progesterone concentrations (P(4)) and transrectal ultrasonography (US). In Experiment 2, sheep were randomly assigned to the same three doses to evaluate a protocol for estrous synchronization using two injections administered 9 days apart. A third trial was performed with ewes treated (9 days apart) with the large dose (H=126 microg; n=12) and with a small dose adjusted for facilitating volume management (LA=43.75 microg; n=12). Presence of estrous cycling was determined in all the ewes by US and P(4) assay, at Days -9, -6, -2, 0 (Day of second cloprostenol injection), 8 and 11. Bleeding and US were done every 4h from 16 h of the beginning of the estrus during the third trial to assess the preovulatory LH surge and timing of ovulation. Additionally, blood samples were drawn at Days 0, 1, 2 and 3 to assess estradiol (Experiments 2 and 3) and P(4) (Experiment 2) concentrations during the ovarian follicular phase. In all experiments, percentage of animals showing luteolysis, preovulatory follicular dynamics and function and percentage of ewes showing behavioral estrus in response to treatment was similar among groups. Timing of estrus for group H was earlier than group L (28.6+/-1.8h compared with 37.1+/-2.4h; Psheep, with the additional advantage of reducing treatment costs.

  4. 16-slice MDCT arthrography of the shoulder: accuracy for detection of glenoid labral and rotator cuff tears

    International Nuclear Information System (INIS)

    Kim, Gang Deuk; Kim, Huoung Jun; Kim, Hye Won; Oh, Jung Taek; Juhng, Seon Kwan; Lee, Sung Ah

    2007-01-01

    We wanted to determine the diagnostic accuracy of 16-slice MDCT arthrography (CTA) for glenoid labral and rotator cuff tears of the shoulder. We enrolled forty-five patients who underwent arthroscopy after CTA for pain or instability of the shoulder joint. The CTA images were analyzed for the existence, sites and types of glenoid labral tears and the presence and severity of rotator cuff tears. We determined the sensitivity, specificity and accuracy of CTA for detecting glenoid labral and rotator cuff tears on the basis of the arthroscopy findings. At arthroscopy, there were 33 SLAP lesions (9 type I, 23 type II and 1 type III), 6 Bankart lesions and 31 rotator cuff lesions (21 supraspinatus, 9 infraspinatus and 1 subscapularis). On CTA, the sensitivity, specificity and accuracy for detecting 24 SLAP lesions, excluding the type I lesions, were 83%, 100% and 91%, the total rotator cuff tears were 90%, 100% and 98%, the full thickness supraspinatus tendon tears were 100%, 94% and 96%, and the partial thickness supraspinatus tendon tears were 29%, 100% and 89%, respectively. 16-slice MDCT arthrography has high accuracy for the diagnosis of abnormality of the glenoid labrum or rotator cuff tears and it can be a useful alternative to MRI or US

  5. 16-slice MDCT arthrography of the shoulder: accuracy for detection of glenoid labral and rotator cuff tears

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gang Deuk; Kim, Huoung Jun; Kim, Hye Won; Oh, Jung Taek; Juhng, Seon Kwan [Wonkwang University Hospital, Iksan (Korea, Republic of); Lee, Sung Ah [Seoul Medical Center, Seoul (Korea, Republic of)

    2007-04-15

    We wanted to determine the diagnostic accuracy of 16-slice MDCT arthrography (CTA) for glenoid labral and rotator cuff tears of the shoulder. We enrolled forty-five patients who underwent arthroscopy after CTA for pain or instability of the shoulder joint. The CTA images were analyzed for the existence, sites and types of glenoid labral tears and the presence and severity of rotator cuff tears. We determined the sensitivity, specificity and accuracy of CTA for detecting glenoid labral and rotator cuff tears on the basis of the arthroscopy findings. At arthroscopy, there were 33 SLAP lesions (9 type I, 23 type II and 1 type III), 6 Bankart lesions and 31 rotator cuff lesions (21 supraspinatus, 9 infraspinatus and 1 subscapularis). On CTA, the sensitivity, specificity and accuracy for detecting 24 SLAP lesions, excluding the type I lesions, were 83%, 100% and 91%, the total rotator cuff tears were 90%, 100% and 98%, the full thickness supraspinatus tendon tears were 100%, 94% and 96%, and the partial thickness supraspinatus tendon tears were 29%, 100% and 89%, respectively. 16-slice MDCT arthrography has high accuracy for the diagnosis of abnormality of the glenoid labrum or rotator cuff tears and it can be a useful alternative to MRI or US.

  6. Performances of low-dose dual-energy CT in reducing artifacts from implanted metallic orthopedic devices

    Energy Technology Data Exchange (ETDEWEB)

    Filograna, Laura [Catholic University of Rome, School of Medicine, University Hospital ' ' A. Gemelli' ' , Department of Radiological Sciences, Institute of Radiology, Rome (Italy); University of Zurich, Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, Zurich (Switzerland); Magarelli, Nicola; Leone, Antonio; Bonomo, Lorenzo [Catholic University of Rome, School of Medicine, University Hospital ' ' A. Gemelli' ' , Department of Radiological Sciences, Institute of Radiology, Rome (Italy); De Waure, Chiara; Calabro, Giovanna Elisa [Catholic University of Rome, School of Medicine, University Hospital ' ' A. Gemelli' ' , Research Centre for Health Technology Assessment, Department of Public Health, Section of Hygiene, Rome (Italy); Finkenstaedt, Tim [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Thali, Michael John [University of Zurich, Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, Zurich (Switzerland)

    2016-07-15

    The objective was to evaluate the performances of dose-reduced dual-energy computed tomography (DECT) in decreasing metallic artifacts from orthopedic devices compared with dose-neutral DECT, dose-neutral single-energy computed tomography (SECT), and dose-reduced SECT. Thirty implants in 20 consecutive cadavers underwent both SECT and DECT at three fixed CT dose indexes (CTDI): 20.0, 10.0, and 5.0 mGy. Extrapolated monoenergetic DECT images at 64, 69, 88, 105, 120, and 130 keV, and individually adjusted monoenergy for optimized image quality (OPTkeV) were generated. In each group, the image quality of the seven monoenergetic images and of the SECT image was assessed qualitatively and quantitatively by visually rating and by measuring the maximum streak artifact respectively. The comparison between SECT and OPTkeV evaluated overall within all groups showed a significant difference (p <0.001), with OPTkeV images providing better images. Comparing OPTkeV with the other DECT images, a significant difference was shown (p <0.001), with OPTkeV and 130-keV images providing the qualitatively best results. The OPTkeV images of 5.0-mGy acquisitions provided percentages of images with scores 1 and 2 of 36 % and 30 % respectively, compared with 0 % and 33.3 % of the corresponding SECT images of 10- and 20-mGy acquisitions. Moreover, DECT reconstructions at the OPTkeV of the low-dose group showed higher CT numbers than the SECT images of dose groups 1 and 2. This study demonstrates that low-dose DECT permits a reduction of artifacts due to metallic implants to be obtained in a similar manner to neutral-dose DECT and better than reduced or neutral-dose SECT. (orig.)

  7. Reduced Albumin Dosing During Large-Volume Paracentesis Is Not Associated with Adverse Clinical Outcomes.

    Science.gov (United States)

    Johnson, Kara B; Mueller, Jessica L; Simon, Tracey G; Zheng, Hui; King, Lindsay Y; Makar, Robert S; Gervais, Debra A; Chung, Raymond T

    2015-07-01

    LVP is used to manage diuretic-resistant ascites in cirrhotic patients. Albumin administration prevents complications including acute kidney injury and paracentesis-induced circulatory dysfunction, but the optimal dose is unclear. We sought to assess adherence to guidelines enacted in July 2011 at our center for reducing the albumin dose administered at large-volume paracentesis (LVP) and evaluate the cost and rate of complications of LVPs before and after guideline enactment. All LVPs performed on cirrhotic patients in our center's Department of Radiology between July 2009 and January 2014 were studied. Outcomes included adherence to guidelines, LVP complications, and administered albumin cost. Groups were compared using Student's t tests for continuous data and Chi-square or Fisher's exact tests for categorical data. A repeated measurements model accounted for patients with multiple LVPs. Of the 935 LVPs, 288 occurred before guideline implementation (group 1) and 647 occurred after (group 2). The mean dose of albumin administered was 13.7 g/L of ascites removed in group 1 versus 10.3 g/L in group 2 (p albumin administration and associated cost savings was still observed. There was no increase in LVP-related complications after guideline implementation or in the adherent group, suggesting that albumin dose can be safely reduced. Future efforts should be directed at enhancing guideline adherence and potentially further reducing albumin dosing.

  8. Study on the method or reducing the operator's exposure dose from a C-Arm system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Sik; Song, Jong Nam [Dept. of Radiological Science, Dongshin University, Naju (Korea, Republic of); Kim, Seung Ok [Dept. of Radiology, Catholic Kwangdong Universty International ST.Mary' s Hospital, Incheon (Korea, Republic of)

    2016-12-15

    In this study, C-Arm equipment is being used as we intend to verify the exposure dose on the operator by the scattering rays during the operation of the C-Arm equipment and to provide an effective method of reducing the exposure dose. Exposure dose is less than the Over Tube method utilizes the C-arm equipment Under Tube the scheme, The result showed that the exposure dose on the operator decreased with a thicker shield, and as the operator moved away from the center line. Moreover, as the research time prolongated, the exposure dose increased, and among the three affixed location of the dosimeter, the most exposure dose was measured at gonadal, then followed by chest and thyroid. However, in consideration of the relationship between the operator and the patient, the distance cannot be increased infinitely and the research time cannot be decreased infinitely in order to reduce the exposure dose. Therefore, by changing the thickness of the radiation shield, the exposure dose on the operator was able to be reduced. If you are using a C-Arm equipment discomfort during surgery because the grounds that the procedure is neglected and close to the dose of radiation shielding made can only increase. Because a separate control room cannot be used for the C-Arm equipment due to its characteristic, the exposure dose on the operator needs to be reduced by reinforcing the shield through an appropriate thickness of radiation shield devices, such as apron, etc. during a treatment.

  9. Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: head-to-head comparison with multidetector CT angiography

    DEFF Research Database (Denmark)

    Gutte, Henrik; Mortensen, Jann; Jensen, Claus Verner

    2009-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer testing, and imaging with either pulmonary ventilation-perfusion (V/Q) scintigraphy or pulmonary multidetector CT (MDCT) angiography. Both V/Q SPECT and MDCT angiography seem to have...... high diagnostic accuracy. However, only limited data directly comparing these 2 modalities are available. Hybrid gamma-camera/MDCT systems have been introduced and allow simultaneous 3-dimensional lung V/Q SPECT and MDCT angiography, suitable for diagnosing PE. The aim of our study was to compare...

  10. Evaluation of bismuth shielding effectiveness in reducing breast absorbed dose during thoracic CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, T. C.; Mourao, A. P.; Santana, P. C.; Silva, T. A. [Federal University of Minas Gerais, Program of Nuclear Science and Techniques, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    Computed Tomography (CT) is an essential method for tracking neoplasia and efficiently diagnosing a wide variety of thoracic diseases. CT is generally considered the most accurate choice for lung examination. Due to the growing use of CT, breast and other superficial and radiosensitive organs are unnecessarily irradiated during radiological procedures, thus requiring the development of strategies appropriate to optimize and, if possible, to reduce the radiation dose. The use of bismuth shielding to reduce radiation dose absorbed by breast during thoracic CT examinations has been the subject of many studies recently published by Brazilian and foreign authors of various fields. The purpose of this paper is both to accurately determine the glandular dose when breast is exposed to radiation and to assess the reduction in absorbed dose during thoracic CT examinations, using a set of Thermoluminescent Dosimeters, an anthropomorphic phantom and bismuth shielding. (Author)

  11. Evaluation of bismuth shielding effectiveness in reducing breast absorbed dose during thoracic CT scan

    International Nuclear Information System (INIS)

    Alonso, T. C.; Mourao, A. P.; Santana, P. C.; Silva, T. A.

    2015-10-01

    Computed Tomography (CT) is an essential method for tracking neoplasia and efficiently diagnosing a wide variety of thoracic diseases. CT is generally considered the most accurate choice for lung examination. Due to the growing use of CT, breast and other superficial and radiosensitive organs are unnecessarily irradiated during radiological procedures, thus requiring the development of strategies appropriate to optimize and, if possible, to reduce the radiation dose. The use of bismuth shielding to reduce radiation dose absorbed by breast during thoracic CT examinations has been the subject of many studies recently published by Brazilian and foreign authors of various fields. The purpose of this paper is both to accurately determine the glandular dose when breast is exposed to radiation and to assess the reduction in absorbed dose during thoracic CT examinations, using a set of Thermoluminescent Dosimeters, an anthropomorphic phantom and bismuth shielding. (Author)

  12. Positive end-expiratory pressure improves gas exchange and pulmonary mechanics during partial liquid ventilation.

    Science.gov (United States)

    Kirmse, M; Fujino, Y; Hess, D; Kacmarek, R M

    1998-11-01

    Partial liquid ventilation (PLV) with perflubron (PFB) has been proposed as an adjunct to the current therapies for the acute respiratory distress syndrome (ARDS). Because PFB has been also referred to as "liquid PEEP," distributing to the most gravity-dependent regions of the lung, less attention has been paid to the amount of applied positive end-expiratory pressure (PEEP). We hypothesized that higher PEEP levels than currently applied are needed to optimize gas exchange, and that the lower inflection point (LIP) of the pressure-volume curve could be used to estimate the amount of PEEP needed when the lung is filled with PFB. Lung injury was induced in 23 sheep by repeated lung lavage with warmed saline until the PaO2/FIO2 ratio fell below 150. Five sheep were used to investigate the change of the LIP when the lung was filled with PFB in increments of 5 ml/kg/body weight to a total of 30 ml/kg/body weight. To evaluate the impact of PEEP set at LIP +1 cm H2O we randomized an additional 15 sheep to three groups with different doses (7.5 ml, 15 ml, 30 ml/kg/body weight) of PFB. In random order a PEEP of 5 cm H2O or PEEP at LIP +1 cm H2O was applied. The LIP decreased with incremental filling of PFB to a minimum at 10 ml (p PFB shifts the LIP to the left, and that setting PEEP at LIP +1 cm H2O improves gas exchange at moderate to high doses of PFB.

  13. The respiratory drive to thoracic motoneurones in the cat and its relation to the connections from expiratory bulbospinal neurones

    Science.gov (United States)

    Saywell, S A; Anissimova, N P; Ford, T W; Meehan, C F; Kirkwood, P A

    2007-01-01

    The descending control of respiratory-related motoneurones in the thoracic spinal cord remains the subject of some debate. In this study, direct connections from expiratory bulbospinal neurones to identified motoneurones were investigated using spike-triggered averaging and the strengths of connection revealed were related to the presence and size of central respiratory drive potentials in the same motoneurones. Intracellular recordings were made from motoneurones in segments T5–T9 of the spinal cord of anaesthetized cats. Spike-triggered averaging from expiratory bulbospinal neurones in the caudal medulla revealed monosynaptic EPSPs in all groups of motoneurones, with the strongest connections to expiratory motoneurones with axons in the internal intercostal nerve. In the latter, connection strength was similar irrespective of the target muscle (e.g. external abdominal oblique or internal intercostal) and the EPSP amplitude was positively correlated with the amplitude of the central respiratory drive potential of the motoneurone. For this group, EPSPs were found in 45/83 bulbospinal neurone/motoneurone pairs, with a mean amplitude of 40.5 μV. The overall strength of the connection supports previous measurements made by cross-correlation, but is about 10 times stronger than that reported in the only previous similar survey to use spike-triggered averaging. Calculations are presented to suggest that this input alone is sufficient to account for all the expiratory depolarization seen in the recorded motoneurones. However, extra sources of input, or amplification of this one, are likely to be necessary to produce a useful motoneurone output. PMID:17204500

  14. Reduced fungicide doses in cereals: Which parameters to consider?

    DEFF Research Database (Denmark)

    Jørgensen, Lise Nistrup

    2015-01-01

    dose. In spring barley the economically optimum input can vary from 0-2 treatments with a total fungicide use equivalent to 0.25 to 0.5 times the recommended dose. Applying reducing rates should never result in significant inferior control and economical yield losses. A recent review concluded......, the pathogen, disease pressure and timing of treatments. Certain diseases are known to require higher input (40- 75% rates) for achieving satisfactory control – this is the case for Septoria leaf blight, Rhynchosporium net blotch and Fusarium head blight, whereas most rust diseases generally have been found...... on well-established disease attack. Rates also have to be adjusted according to canopy structures. Early timing on a small canopy requires less fungicide than a full canopy around heading. The knowledge gathered concerning fungicide rates has led to great focus on the importance of optimizing timing...

  15. Influence of tube voltage on CT attenuation, radiation dose, and image quality: phantom study

    International Nuclear Information System (INIS)

    Li Fengtan; Li Dong; Zhang Yunting

    2013-01-01

    Objective: To assess the influence of tube current and tube voltage on the CT attenuation, radiation dose, and image quality. Methods: A total of 113 saline solutions with decreasing dilution of contrast medium (370 mg I/ml) was produced. MDCT scan was performed with 15 series of different settings of tube current and tube voltage. CT attenuations with 15 series of different settings were all measured, and influence of tube current and tube voltage on CT attenuations was analyzed. CT dose index (CTDIvol) was recorded. The CT attenuations with different tube voltage and current were compared with one-way ANOVA and Kruskal-Wallis rank sum test. The correlation of CT attenuation with different tube voltage and the influence of tube voltage and current on radiation dose and image quality were tested by correlation analysis. Results: Tube current (250, 200, 150, 100, and 50 mA) had no significant effect on CT attenuation (F = 0.001, 0.008, 0.075, P > 0.05), while tube voltage (120, 100, and 80 kV) had significant effect (H = 17.906, 17.906, 13.527, 20.124, 23.563, P < 0.05). The correlation between CT attenuation and tube voltage was determined with equation: CT attenuatio N_1_0_0 _k_V = 1.561 × CT attenuatio N_1_2_0 _k_v + 4.0818, CT attenuatio N_8_0 _k_v = 1.2131 × CT attenuatio N_1_2_0 _k_v + 0.9283. The influence of tube voltage on radiation dose and image quality was also analyzed, and equations were also obtained: N_1_2_0 -k_v = -5.9771 Ln (D_1_2_0 kv) + 25.412, N_1_0_0 _k_v = -10.544 Ln (D_1_0_0 _k_v) + 36.262, N_8_0 _k_v = -25.326 Ln (D_8_0 _k_v) + 62.816. According to the results of relationship among CT attenuation, radiation dose, and image quality, lower tube voltage with higher tube current can reduce the radiation dose. Conclusions: Lower tube voltage can reduce the radiation dose. However, CT attenuation was influenced, and correction should be done with the equations. (authors)

  16. Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols

    International Nuclear Information System (INIS)

    Kim, Moon Chan

    2009-01-01

    that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  17. [Study of personal best value of peak expiratory flow in patients with asthma--comparison of the highest value of daily PEF under good control and the highest value of daily PEF obtained after using repeated inhaled beta2-agonist during high-dose inhaled steroid treatment].

    Science.gov (United States)

    Watanabe, Naoto; Makino, Sohei; Kihara, Norio; Fukuda, Takeshi

    2008-12-01

    In the guideline for asthma management, it is important to find the personal best value of peak expiratory flow (best PEF). Recently, we have substituted the highest value of PEF in daily life under good control (daily highest PEF) for the best PEF. In the present study, we considered whether the daily highest PEF could be used as the best PEF or not. Subjects were 30 asthmatics who were well controlled but whose baseline PEF values were less than 80 percent of predicted values. We compared the daily highest PEF and the highest of PEF obtained after repeated inhaled beta2-agonist (salbutamol MDI every 20 minutes three times). All subjects then received 1600 microg/day of beclomethasone dipropionate (BDP) for 4 to 8 weeks. We studied the effect of high-dose inhaled steroid treatment on each PEF value and compared the daily highest PEF and the highest PEF obtained after using repeated salbutamol MDI during high dose inhaled steroid therapy on the examination day again. The baseline PEF, daily highest PEF and the highest PEF obtained after salbutamol MDI were significantly less than the each values obtained after high-dose BDP. The best PEF value of them was the value obtained after repeated salbutamol MDI during high dose BDP. We suggest that the daily highest PEF under good control is not a substitute for best PEF because it changes according to the degree of improvement of airway inflammation. We recommend that a course of high dose inhaled steroid is effective in finding the best value of PEF for each individual with moderate asthma.

  18. MRI, MDCT features, and clinical outcome of extremity leiomyosarcomas: experience in 47 patients

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, Robert W.; Shinagare, Atul B. [Brigham and Women' s Hospital, Harvard Medical School, Department of Radiology, Boston, MA (United States); Tirumani, Sree Harsha; Jagannathan, Jyothi P.; Ramaiya, Nikhil H. [Brigham and Women' s Hospital, Harvard Medical School, Department of Radiology, Boston, MA (United States); Dana-Farber Cancer Institute, Harvard Medical School, Department of Imaging, Boston, MA (United States); Kurra, Vikram [Dana-Farber Cancer Institute, Harvard Medical School, Department of Imaging, Boston, MA (United States); Hornick, Jason L. [Brigham and Women' s Hospital, Harvard Medical School, Department of Pathology, Boston, MA (United States)

    2014-05-15

    To describe MRI, MDCT features, and clinical outcome of extremity leiomyosarcomas (LMS). In this IRB-approved, HIPAA-compliant retrospective study, we included 47 patients (23 women, 24 men; mean age: 55.3 years, range: 17-85 years) with pathologically confirmed extremity LMS seen at our adult tertiary cancer center between 2000 and 2012. MRI/MDCT of primary tumors in 23 patients and follow-up in all patients were reviewed by two radiologists in consensus. Clinical data were extracted from electronic medical records. Primary tumors were distributed in bones (6 out of 47), deep soft tissues (24 out of 47), and superficial soft tissues (17 out of 47). On imaging (bone = 4, deep soft tissue = 11, superficial soft tissue = 8), compared with skeletal muscle, they were T1 iso-hypointense and T2 hyperintense. Bone LMS were metaphyseal tumors with cortical destruction (3 out of 4). Deep soft-tissue LMS were large with hemorrhage (7 out of 11) and necrosis (10 out of 11). Superficial soft-tissue LMS were relatively smaller, homogeneously enhancing (6 out of 8) tumors. Distant metastases developed in 32 out of 47 patients (bone LMS [6 out of 6], deep soft-tissue LMS [18 out of 24], superficial soft-tissue LMS [8 out of 17]), commonly to lung (29 out of 47) and bone (14 out of 47). At the time of writing, 22 out of 36 patients (bone LMS [4 out of 6], deep soft-tissue LMS [15 out of 24], superficial soft-tissue LMS [4 out of 17]) have died. There was no statistically significant correlation between metastatic disease and tumor size or grade. Extremity LMS arise in bones and in the deep and superficial soft tissues, frequently metastasize to the lungs, and have a poor prognosis. Superficial LMS tend to have a better prognosis than bone or deep soft-tissue LMS. (orig.)

  19. MRI, MDCT features, and clinical outcome of extremity leiomyosarcomas: experience in 47 patients

    International Nuclear Information System (INIS)

    Gordon, Robert W.; Shinagare, Atul B.; Tirumani, Sree Harsha; Jagannathan, Jyothi P.; Ramaiya, Nikhil H.; Kurra, Vikram; Hornick, Jason L.

    2014-01-01

    To describe MRI, MDCT features, and clinical outcome of extremity leiomyosarcomas (LMS). In this IRB-approved, HIPAA-compliant retrospective study, we included 47 patients (23 women, 24 men; mean age: 55.3 years, range: 17-85 years) with pathologically confirmed extremity LMS seen at our adult tertiary cancer center between 2000 and 2012. MRI/MDCT of primary tumors in 23 patients and follow-up in all patients were reviewed by two radiologists in consensus. Clinical data were extracted from electronic medical records. Primary tumors were distributed in bones (6 out of 47), deep soft tissues (24 out of 47), and superficial soft tissues (17 out of 47). On imaging (bone = 4, deep soft tissue = 11, superficial soft tissue = 8), compared with skeletal muscle, they were T1 iso-hypointense and T2 hyperintense. Bone LMS were metaphyseal tumors with cortical destruction (3 out of 4). Deep soft-tissue LMS were large with hemorrhage (7 out of 11) and necrosis (10 out of 11). Superficial soft-tissue LMS were relatively smaller, homogeneously enhancing (6 out of 8) tumors. Distant metastases developed in 32 out of 47 patients (bone LMS [6 out of 6], deep soft-tissue LMS [18 out of 24], superficial soft-tissue LMS [8 out of 17]), commonly to lung (29 out of 47) and bone (14 out of 47). At the time of writing, 22 out of 36 patients (bone LMS [4 out of 6], deep soft-tissue LMS [15 out of 24], superficial soft-tissue LMS [4 out of 17]) have died. There was no statistically significant correlation between metastatic disease and tumor size or grade. Extremity LMS arise in bones and in the deep and superficial soft tissues, frequently metastasize to the lungs, and have a poor prognosis. Superficial LMS tend to have a better prognosis than bone or deep soft-tissue LMS. (orig.)

  20. Selection of peripheral intravenous catheters with 24-gauge side-holes versus those with 22-gauge end-hole for MDCT: A prospective randomized study

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Akio, E-mail: a.akahane@gmail.com [Department of Radiology, Iwate Medical University School of Medicine, 19-1 Uchimaru, Morioka 020-8505 (Japan); Kato, Kenichi, E-mail: kkato@iwate-med.ac.jp [Department of Radiology, Iwate Medical University School of Medicine, 19-1 Uchimaru, Morioka 020-8505 (Japan); Kamata, Masayoshi, E-mail: kamataaoi@yahoo.co.jp [Iwate Medical University Hospital, 19-1 Uchimaru, Morioka 020-8505 (Japan); Suzuki, Tomohiro, E-mail: suzukitomohiro123@gmail.com [Department of Radiology, Iwate Medical University School of Medicine, 19-1 Uchimaru, Morioka 020-8505 (Japan); Suzuki, Michiko, E-mail: mamimichiko@me.com [Department of Radiology, Iwate Medical University School of Medicine, 19-1 Uchimaru, Morioka 020-8505 (Japan); Nakayama, Manabu, E-mail: gakuymgt@yahoo.co.jp [Department of Radiology, Iwate Medical University School of Medicine, 19-1 Uchimaru, Morioka 020-8505 (Japan); Tomabechi, Makiko, E-mail: mtomabechi@mac.com [Department of Radiology, Iwate Medical University School of Medicine, 19-1 Uchimaru, Morioka 020-8505 (Japan); Nakasato, Tatsuhiko, E-mail: nakasato77@gmail.com [Department of Radiology, Southern Tohoku Research Institute for Neuroscience, 7-115 Yatsuyamada, Koriyama 963-8563 (Japan); Ehara, Shigeru, E-mail: ehara@iwate-med.ac.jp [Department of Radiology, Iwate Medical University School of Medicine, 19-1 Uchimaru, Morioka 020-8505 (Japan)

    2017-02-15

    Highlights: • We compared 24-gauge side-hole and conventional 22-gauge end-hole catheters in MDCT. • The 24-gauge side-hole catheter is noninferior to the 22-gauge end-hole catheter. • The 24-gauge side-hole catheter is safe and facilitates optimal enhancement quality. • The 24-gauge side-hole catheter is suitable for patients with narrow or fragile veins. - Abstract: Purpose: To compare the 24-gauge side-holes catheter and conventional 22-gauge end-hole catheter in terms of safety, injection pressure, and contrast enhancement on multi-detector computed tomography (MDCT). Materials & methods: In a randomized single-center study, 180 patients were randomized to either the 24-gauge side-holes catheter or the 22-gauge end-hole catheter groups. The primary endpoint was safety during intravenous administration of contrast material for MDCT, using a non-inferiority analysis (lower limit 95% CI greater than −10% non-inferiority margin for the group difference). The secondary endpoints were injection pressure and contrast enhancement. Results: A total of 174 patients were analyzed for safety during intravenous contrast material administration for MDCT. The overall extravasation rate was 1.1% (2/174 patients); 1 (1.2%) minor episode occurred in the 24-gauge side-holes catheter group and 1 (1.1%) in the 22-gauge end-hole catheter group (difference: 0.1%, 95% CI: −3.17% to 3.28%, non-inferiority P = 1). The mean maximum pressure was higher with the 24-gauge side-holes catheter than with the 22-gauge end-hole catheter (8.16 ± 0.95 kg/cm{sup 2} vs. 4.79 ± 0.63 kg/cm{sup 2}, P < 0.001). The mean contrast enhancement of the abdominal aorta, celiac artery, superior mesenteric artery, and pancreatic parenchyma in the two groups were not significantly different. Conclusion: In conclusion, our study showed that the 24-gauge side-holes catheter is safe and suitable for delivering iodine with a concentration of 300 mg/mL at a flow-rate of 3 mL/s, and it may contribute to

  1. In-vivo assessment of femoral bone strength using Finite Element Analysis (FEA based on routine MDCT imaging: a preliminary study on patients with vertebral fractures.

    Directory of Open Access Journals (Sweden)

    Hans Liebl

    Full Text Available To experimentally validate a non-linear finite element analysis (FEA modeling approach assessing in-vitro fracture risk at the proximal femur and to transfer the method to standard in-vivo multi-detector computed tomography (MDCT data of the hip aiming to predict additional hip fracture risk in subjects with and without osteoporosis associated vertebral fractures using bone mineral density (BMD measurements as gold standard.One fresh-frozen human femur specimen was mechanically tested and fractured simulating stance and clinically relevant fall loading configurations to the hip. After experimental in-vitro validation, the FEA simulation protocol was transferred to standard contrast-enhanced in-vivo MDCT images to calculate individual hip fracture risk each for 4 subjects with and without a history of osteoporotic vertebral fractures matched by age and gender. In addition, FEA based risk factor calculations were compared to manual femoral BMD measurements of all subjects.In-vitro simulations showed good correlation with the experimentally measured strains both in stance (R2 = 0.963 and fall configuration (R2 = 0.976. The simulated maximum stress overestimated the experimental failure load (4743 N by 14.7% (5440 N while the simulated maximum strain overestimated by 4.7% (4968 N. The simulated failed elements coincided precisely with the experimentally determined fracture locations. BMD measurements in subjects with a history of osteoporotic vertebral fractures did not differ significantly from subjects without fragility fractures (femoral head: p = 0.989; femoral neck: p = 0.366, but showed higher FEA based risk factors for additional incident hip fractures (p = 0.028.FEA simulations were successfully validated by elastic and destructive in-vitro experiments. In the subsequent in-vivo analyses, MDCT based FEA based risk factor differences for additional hip fractures were not mirrored by according BMD measurements. Our data suggests, that MDCT

  2. Segmentation of expiratory and inspiratory sounds in baby cry audio recordings using hidden Markov models.

    Science.gov (United States)

    Aucouturier, Jean-Julien; Nonaka, Yulri; Katahira, Kentaro; Okanoya, Kazuo

    2011-11-01

    The paper describes an application of machine learning techniques to identify expiratory and inspiration phases from the audio recording of human baby cries. Crying episodes were recorded from 14 infants, spanning four vocalization contexts in their first 12 months of age; recordings from three individuals were annotated manually to identify expiratory and inspiratory sounds and used as training examples to segment automatically the recordings of the other 11 individuals. The proposed algorithm uses a hidden Markov model architecture, in which state likelihoods are estimated either with Gaussian mixture models or by converting the classification decisions of a support vector machine. The algorithm yields up to 95% classification precision (86% average), and its ability generalizes over different babies, different ages, and vocalization contexts. The technique offers an opportunity to quantify expiration duration, count the crying rate, and other time-related characteristics of baby crying for screening, diagnosis, and research purposes over large populations of infants.

  3. Control of positive end-expiratory pressure (PEEP for small animal ventilators

    Directory of Open Access Journals (Sweden)

    Leão Nunes Marcelo V

    2010-07-01

    Full Text Available Abstract Background The positive end-expiratory pressure (PEEP for the mechanical ventilation of small animals is frequently obtained with water seals or by using ventilators developed for human use. An alternative mechanism is the use of an on-off expiratory valve closing at the moment when the alveolar pressure is equal to the target PEEP. In this paper, a novel PEEP controller (PEEP-new and the PEEP system of a commercial small-animal ventilator, both based on switching an on-off valve, are evaluated. Methods The proposed PEEP controller is a discrete integrator monitoring the error between the target PEEP and the airways opening pressure prior to the onset of an inspiratory cycle. In vitro as well as in vivo experiments with rats were carried out and the PEEP accuracy, settling time and under/overshoot were considered as a measure of performance. Results The commercial PEEP controller did not pass the tests since it ignores the airways resistive pressure drop, resulting in a PEEP 5 cmH2O greater than the target in most conditions. The PEEP-new presented steady-state errors smaller than 0.5 cmH2O, with settling times below 10 s and under/overshoot smaller than 2 cmH2O. Conclusion The PEEP-new presented acceptable performance, considering accuracy and temporal response. This novel PEEP generator may prove useful in many applications for small animal ventilators.

  4. Frequency and severity of reactions to a 325-mg aspirin dose during desensitization.

    Science.gov (United States)

    Schuler, Charles F; Baldwin, James L; Baptist, Alan P

    2017-03-01

    The frequency with which patients with aspirin-exacerbated respiratory disease (AERD) react to 325 mg of aspirin during aspirin desensitization, or fail to react at all, is not fully known. To determine the rate and type of reaction at 325 mg of aspirin during desensitization. A retrospective study of 104 patients who underwent aspirin desensitization from 2010 to 2016 was performed. A standard desensitization protocol (starting at 20-40 mg, progressing through 325 mg, and extinguishing reactions by dose repetition) was used. Reactions were defined by upper respiratory tract symptoms, lower respiratory tract symptoms, and/or forced expiratory volume in 1 second decrease of 15% or greater. Patients who did and did not react were compared by logistic regression. Eighty-four patients reacted (81%) and 20 did not (19%). Seventy-seven patients who had a provoking reaction at 162 mg of aspirin or less subsequently extinguished their reactions before they reached a dose of 325 mg and had no problems at that dose; one subsequent 325-mg reaction occurred during a protocol violation. One initial provoking reaction to 325 mg occurred. Both 325-mg reactions were mild, and neither met the forced expiratory volume in 1 second criterion for a clinically meaningful change. The remaining 5 patients could not complete the protocol because of persistent reactions or social reasons. Reactors were more likely to have had asthma for more than 10 years than nonreactors (odds ratio, 3.2; 95% confidence interval, 1.0-10.3; P = .05). During aspirin desensitization for AERD, provoking reactions at the 325-mg dose are rare (1%) and mild. Patients who react at 162 mg or less and extinguish their reactions may be able to administer the 325-mg dose at home. Copyright © 2016 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  5. The value of coronal image reconstructions of HRCT using MDCT for the assessment of bronchiectasis: experiment with 64 MDCTs

    International Nuclear Information System (INIS)

    Choi, Soo Jin; Kim, Hyung Sik; Jeong, Sung Hwan; Jin, Wook; Yang, Dal Mo

    2006-01-01

    The aim of our study was to evaluate the value of coronal image reconstructions of HRCT with using 64 MDCT scans for the assessment of bronchiectasis. Chest CT scans (0.6-mm collimation, table speed of 14 mm/sec and a rotation time of 0.5 sec) that employed 64 MDCT images (Somatom Sensation 64, Siemens) without contrast media were performed in 56 patients (21 males and 35 females, mean age: 55 years) who displayed hemoptysis. The images were reconstructed with a 1 mm slice thickness in the axial (10 mm apart) and coronal (10 mm apart) planes with using a high frequency algorithm, and they were sent to PACS monitors. The axial images were assessed with and without the coronal images by two radiologists at two separate occasions. The presence of bronchiectasis was decided upon by consensus diagnosis of the two radiologists. The detection rates of bronchiectasis were compared between the readings with using the axial images alone and the readings with using both the axial and coronal images. The detection rate of bronchiectasis was significantly higher with using both the axial and coronal images than with using with axial images alone (82.1%, 46/56 patients Vs 64.3%, 36/56 patients, respectively, ρ = 0.001). The detection rates for all the lobes, except for the superior division of the left upper lobe, were significantly improved with using both the axial and coronal images (RUL; ρ = 0.013, RML; ρ = 0.002, RLL; 0.024, Lt lingular segment; ρ = 0.004, LLL; ρ = 0.018). The coronal images of HRCT with using 64 MDCT improved the detection rate of bronchiectasis in the patients with hemoptysis when they were used in conjunction with the standard axial images. We suggest that HRCT with the coronal images should be obtained for the patients with hemoptysis, despite that the simple chest radiographs are often normal or they have non-specific findings

  6. The value of coronal image reconstructions of HRCT using MDCT for the assessment of bronchiectasis: experiment with 64 MDCTs

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Soo Jin; Kim, Hyung Sik; Jeong, Sung Hwan; Jin, Wook; Yang, Dal Mo [Gachon University of Medicine and Science, Incheon (Korea, Republic of)

    2006-09-15

    The aim of our study was to evaluate the value of coronal image reconstructions of HRCT with using 64 MDCT scans for the assessment of bronchiectasis. Chest CT scans (0.6-mm collimation, table speed of 14 mm/sec and a rotation time of 0.5 sec) that employed 64 MDCT images (Somatom Sensation 64, Siemens) without contrast media were performed in 56 patients (21 males and 35 females, mean age: 55 years) who displayed hemoptysis. The images were reconstructed with a 1 mm slice thickness in the axial (10 mm apart) and coronal (10 mm apart) planes with using a high frequency algorithm, and they were sent to PACS monitors. The axial images were assessed with and without the coronal images by two radiologists at two separate occasions. The presence of bronchiectasis was decided upon by consensus diagnosis of the two radiologists. The detection rates of bronchiectasis were compared between the readings with using the axial images alone and the readings with using both the axial and coronal images. The detection rate of bronchiectasis was significantly higher with using both the axial and coronal images than with using with axial images alone (82.1%, 46/56 patients Vs 64.3%, 36/56 patients, respectively, {rho} = 0.001). The detection rates for all the lobes, except for the superior division of the left upper lobe, were significantly improved with using both the axial and coronal images (RUL; {rho} = 0.013, RML; {rho} = 0.002, RLL; 0.024, Lt lingular segment; {rho} = 0.004, LLL; {rho} = 0.018). The coronal images of HRCT with using 64 MDCT improved the detection rate of bronchiectasis in the patients with hemoptysis when they were used in conjunction with the standard axial images. We suggest that HRCT with the coronal images should be obtained for the patients with hemoptysis, despite that the simple chest radiographs are often normal or they have non-specific findings.

  7. Dose reduction and image quality optimizations in CT of pediatric and adult patients: phantom studies

    International Nuclear Information System (INIS)

    Jeon, P-H; Lee, C-L; Kim, D-H; Lee, Y-J; Kim, H-J; Jeon, S-S

    2014-01-01

    Multi-detector computed tomography (MDCT) can be used to easily and rapidly perform numerous acquisitions, possibly leading to a marked increase in the radiation dose to individual patients. Technical options dedicated to automatically adjusting the acquisition parameters according to the patient's size are of specific interest in pediatric radiology. A constant tube potential reduction can be achieved for adults and children, while maintaining a constant detector energy fluence. To evaluate radiation dose, the weighted CT dose index (CTDIw) was calculated based on the CT dose index (CTDI) measured using an ion chamber, and image noise and image contrast were measured from a scanned image to evaluate image quality. The dose-weighted contrast-to-noise ratio (CNRD) was calculated from the radiation dose, image noise, and image contrast measured from a scanned image. The noise derivative (ND) is a quality index for dose efficiency. X-ray spectra with tube voltages ranging from 80 to 140 kVp were used to compute the average photon energy. Image contrast and the corresponding contrast-to-noise ratio (CNR) were determined for lesions of soft tissue, muscle, bone, and iodine relative to a uniform water background, as the iodine contrast increases at lower energy (i.e., k-edge of iodine is 33 keV closer to the beam energy) using mixed water-iodine contrast normalization (water 0, iodine 25, 100, 200, and 1000 HU, respectively). The proposed values correspond to high quality images and can be reduced if only high-contrast organs are assessed. The potential benefit of lowering the tube voltage is an improved CNRD, resulting in a lower radiation dose and optimization of image quality. Adjusting the tube potential in abdominal CT would be useful in current pediatric radiography, where the choice of X-ray techniques generally takes into account the size of the patient as well as the need to balance the conflicting requirements of diagnostic image quality and radiation dose

  8. A Third-Generation Adaptive Statistical Iterative Reconstruction Technique: Phantom Study of Image Noise, Spatial Resolution, Lesion Detectability, and Dose Reduction Potential.

    Science.gov (United States)

    Euler, André; Solomon, Justin; Marin, Daniele; Nelson, Rendon C; Samei, Ehsan

    2018-06-01

    The purpose of this study was to assess image noise, spatial resolution, lesion detectability, and the dose reduction potential of a proprietary third-generation adaptive statistical iterative reconstruction (ASIR-V) technique. A phantom representing five different body sizes (12-37 cm) and a contrast-detail phantom containing lesions of five low-contrast levels (5-20 HU) and three sizes (2-6 mm) were deployed. Both phantoms were scanned on a 256-MDCT scanner at six different radiation doses (1.25-10 mGy). Images were reconstructed with filtered back projection (FBP), ASIR-V with 50% blending with FBP (ASIR-V 50%), and ASIR-V without blending (ASIR-V 100%). In the first phantom, noise properties were assessed by noise power spectrum analysis. Spatial resolution properties were measured by use of task transfer functions for objects of different contrasts. Noise magnitude, noise texture, and resolution were compared between the three groups. In the second phantom, low-contrast detectability was assessed by nine human readers independently for each condition. The dose reduction potential of ASIR-V was estimated on the basis of a generalized linear statistical regression model. On average, image noise was reduced 37.3% with ASIR-V 50% and 71.5% with ASIR-V 100% compared with FBP. ASIR-V shifted the noise power spectrum toward lower frequencies compared with FBP. The spatial resolution of ASIR-V was equivalent or slightly superior to that of FBP, except for the low-contrast object, which had lower resolution. Lesion detection significantly increased with both ASIR-V levels (p = 0.001), with an estimated radiation dose reduction potential of 15% ± 5% (SD) for ASIR-V 50% and 31% ± 9% for ASIR-V 100%. ASIR-V reduced image noise and improved lesion detection compared with FBP and had potential for radiation dose reduction while preserving low-contrast detectability.

  9. Reducing Dose Uncertainty for Spot-Scanning Proton Beam Therapy of Moving Tumors by Optimizing the Spot Delivery Sequence

    International Nuclear Information System (INIS)

    Li, Heng; Zhu, X. Ronald; Zhang, Xiaodong

    2015-01-01

    Purpose: To develop and validate a novel delivery strategy for reducing the respiratory motion–induced dose uncertainty of spot-scanning proton therapy. Methods and Materials: The spot delivery sequence was optimized to reduce dose uncertainty. The effectiveness of the delivery sequence optimization was evaluated using measurements and patient simulation. One hundred ninety-one 2-dimensional measurements using different delivery sequences of a single-layer uniform pattern were obtained with a detector array on a 1-dimensional moving platform. Intensity modulated proton therapy plans were generated for 10 lung cancer patients, and dose uncertainties for different delivery sequences were evaluated by simulation. Results: Without delivery sequence optimization, the maximum absolute dose error can be up to 97.2% in a single measurement, whereas the optimized delivery sequence results in a maximum absolute dose error of ≤11.8%. In patient simulation, the optimized delivery sequence reduces the mean of fractional maximum absolute dose error compared with the regular delivery sequence by 3.3% to 10.6% (32.5-68.0% relative reduction) for different patients. Conclusions: Optimizing the delivery sequence can reduce dose uncertainty due to respiratory motion in spot-scanning proton therapy, assuming the 4-dimensional CT is a true representation of the patients' breathing patterns.

  10. Depiction of normal gastrointestinal anatomy with MDCT: Comparison of low- and high-attenuation oral contrast media

    International Nuclear Information System (INIS)

    Erturk, Sukru Mehmet; Mortele, Koenraad J.; Oliva, Maria-Raquel; Ichikawa, Tomoaki; Silverman, Stuart G.; Cantisani, Vito; Pagliara, Elisa; Ros, Pablo R.

    2008-01-01

    Purpose: To compare low- and high-attenuation oral contrast media for depiction of normal gastrointestinal anatomy with multidetector-row computed tomography (MDCT). Materials and methods: A prospective, randomized study of 90 consecutive patients without known or suspected gastrointestinal disease was conducted after the approval of our Institutional Review Board. All patients underwent IV contrast-enhanced abdominal and pelvic CT scans after oral administration of 900 ml of either low- or high-attenuation barium sulphate suspension. Using a five-point scale, two radiologists independently graded distention and wall visualization of stomach, duodenum, jejunum, and ileum. The degree of distention and wall visualization was compared using Mann-Whitney U-test. Results: Duodenal, jejunal and ileal distention (p < 0.05, <0.001, <0.001, respectively) and wall visualization (p < 0.05, <0.01, <0.05, respectively) scores with low-attenuation contrast medium were significantly higher than those with high-attenuation barium sulphate preparation, for reader 1. Duodenal and jejunal wall visualization scores with low-attenuation contrast medium (p < 0.05, <0.01, respectively) were significantly higher than those with high-attenuation contrast medium, for reader 2. Interobserver agreement was fair to good for both distention (κ-range: 0.41-0.74) and wall visualization (κ-range: 0.48-0.71). Conclusion: MDCT with low-attenuation contrast medium provides distention and wall visualization of the GI tract that is equal or better than high-attenuation contrast medium

  11. Reducing methods of patients exposed dose using auto exposure control system in digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Seong Gyu [Dept. of Diagnostic Radiology, Dong A University Medical Center, Busan (Korea, Republic of)

    2013-06-15

    This study was carried out to reduce patient dose through focus-detector distance, kilovoltage, and a combination of copper filters. In the C, L-spine lateral, Skull AP views were obtained by making changes of 60-100 kV in tube voltage and of 100-200 cm in focus-detector distance and by adding a copper filter when using an auto exposure control device in the digital radiography equipment. The incident dose showed 90 kV, 0.3 mmCu in C-spine lateral with 0.06 mGy under the condition of 200 cm; 100 kV, 0.3 mmCu with 0.40 mGy under the condition of 200 cm and 90 kV 0.3 mmCu in Skull AP with the lowest value of 0.24 mGy under the condition of 140 cm. It was observed that entrance surface dose decreased the most when was increased by 150 cm, 70 kV (C-spine lateral), 81 kV (L-spine lateral). It was also found out that as the between the focus-detector increased in the expansion of the video decreased but the difference was not significant when the distance was 180 cm or more. Skull AP showed the most reduction in the entrance surface dose when the tube voltage was changed by 80 kV, 0.1 mmCu, and 120 cm. Therefore, when using the automatic exposure control device, it is recommended to use the highest tube voltage if possible and to increase focus-detector distance at least by 150-200 cm in wall and 120-140 cm in table in consideration of the radiotechnologist's physical conditions, and to combine 0.1-0.3 mmCu and higher filters. It is thus expected to reduce patient dose by avoiding distortion of images and reducing the entrance surface dose.

  12. Suggestion of the manual exposure condition guideline for reducing patient dose in digital breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Eun Ae [Dept. of Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of); Lee, In Ja [Dept. of Radiologic Technology, Dongnam Health University, Suwon (Korea, Republic of)

    2016-12-15

    The conditions after exposure to digital mammography and digital breast tomosynthesis were analyzed. The examinations for the ACR phantom were done using manual exposure, not auto exposure, to examine image discrimination and patient dose. As a result, the following results were derived: In the CC exposure , the kVp was 2kVp higher while mAs decreased to 58.6% for the 3D tomography. Such result showed an approximate decrease of 60mAs. At that time, the patients Average Glandular Dose (AGD) was 1.65mGy in 2D and 1.87mGy in 3D; thus, AGD of 3D was shown to have about 1.13 times higher. The result of the manual exposure revealed a reduced mAs of up to 80%; there was no effect in the assessment standard in terms of image discrimination, resulting in more than 10 points. When mAs was reduced to 80% in the manual exposure for ACR phantom, AGD was decreased to 0.66mGy. The diagnostic values of images were maintained and patients dose was reduced in the manual exposure in the AEC condition for 3D. Since the use of 3D has recently increased, using the manual exposure has been recommended in this study to improve the diagnostic value, while, simultaneously reducing patients dose.

  13. Usefulness and safety of propranolol injection into vein for acquisition of coronary multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Sekine, Takako; Kodama, Takahide; Kondo, Takeshi

    2010-01-01

    A low heart rate (HR), associated with a prolonged slow filling phase (SF), is necessary to obtain a high quality coronary CT at a low radiation dose with conventional 64 multidetector-row computed tomography (MDCT). The purpose of our study was to confirm the safety of injecting propranolol (2-10 mg) into the vein for lowering heart rate in patients requiring MDCT and to document the effect of the drug on HR, PQ and SF. Of 1290 consecutive patients who were initially considered for enrollment in the coronary MDCT study, 40 patients with atrial fibrillations, 3 with atrial flutters, and 13 with artificial pacemakers were excluded. Of the remaining 1234 patients (M/F=714/520), 331 had already taken an oral beta-blocker before the CT examination, and were included in the study. In patients with no contraindications, propranolol was aggressively injected (2-10 mg) into the vein to reduce the HR. In patients not taking an oral beta blocker, 2 mg propranolol reduced the HR by -10±5 bpm and 10 mg, by -20±7 bpm. However, in patients taking an oral beta-blocker, the decrease in HR by propranolol was minimal (2 mg, -6±4 bpm; 10 mg, -10±6 bpm). Propranolol significantly prolonged the PQ interval (from 169±27 to 179±29 ms, P<0.0001), and SF (from 125±69 to 264±79 ms, P<0.0001). Adverse effects of propranolol injection were observed in only 3 [2 mild hypotension and 1 paroxysmal atrial fibrillation (recovered to sinus rhythm by DC counter shock)] of 3212 patients. All 3 patients became stable after 1 or 2 hours of rest and could return home. Propranolol injection was a relatively safe and useful method to reduce HR and prolong SF, necessary for obtaining high quality coronary MDCT with a low radiation dose. (author)

  14. Inter- and intrascanner variability of pulmonary nodule volumetry on low-dose 64-row CT: an anthropomorphic phantom study

    Science.gov (United States)

    Xie, X; Willemink, M J; Zhao, Y; de Jong, P A; van Ooijen, P M A; Oudkerk, M; Greuter, M J W

    2013-01-01

    Objective: To assess inter- and intrascanner variability in volumetry of solid pulmonary nodules in an anthropomorphic thoracic phantom using low-dose CT. Methods: Five spherical solid artificial nodules [diameters 3, 5, 8, 10 and 12 mm; CT density +100 Hounsfield units (HU)] were randomly placed inside an anthropomorphic thoracic phantom in different combinations. The phantom was examined on two 64-row multidetector CT (64-MDCT) systems (CT-A and CT-B) from different vendors with a low-dose protocol. Each CT examination was performed three times. The CT examinations were evaluated twice by independent blinded observers. Nodule volume was semi-automatically measured by dedicated software. Interscanner variability was evaluated by Bland–Altman analysis and expressed as 95% confidence interval (CI) of relative differences. Intrascanner variability was expressed as 95% CI of relative variation from the mean. Results: No significant difference in CT-derived volume was found between CT-A and CT-B, except for the 3-mm nodules (pvolumetry of artificial pulmonary nodules between 5 mm and 12 mm in diameter. Inter- and intrascanner variability decreases at a larger nodule size to a maximum of 4.9% for ≥8 mm nodules. Advances in knowledge: The commonly accepted cut-off of 25% to determine nodule growth has the potential to be reduced for ≥8 mm nodules. This offers the possibility of reducing the interval for repeated CT scans in lung cancer screenings. PMID:23884758

  15. Consideration of Adverse Reaction to MDCT Contrast Media

    International Nuclear Information System (INIS)

    Yang, Won Seok; Shin, Seong Gyu

    2012-01-01

    In this experiment, we investigated 82 patients who suffered adverse reactions due to contrast medium. We selected the subjects out of 21,178 people who had an intravenous injection of contrast medium to undergo MDCT examination at one university hospital in Busan in 2007. As a result, the largest groups of the patients were as follows. 52.4% of the patients were male when classify by gender; 28.0% of the patients were 50's by age; 45% of the patients got when it was spring(April and March); 75.6% of the patients had a side effects when the speed of injection is 2.5 mL/sec; 58.5% of the patients were suffered when the volume of injected contrast medium is over 130 mL. Urticaria was the main symptom of side effect as 26.8%. And the main treatment for the effect was alleviating the symptoms before making patients to return home. Thus, practical preventive measures are needed as follows: use the OCS system to observe warning signs at risky patients, secure warming spaces for patients to cope with season changing, prepare enough emergency kits for the patients in danger, and establish CPR call systems, explain the risk of contrast medium and get agree about using contrast medium.

  16. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT.

    Science.gov (United States)

    Gay, F; Pavia, Y; Pierrat, N; Lasalle, S; Neuenschwander, S; Brisse, H J

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. • Iterative reconstruction helps lower radiation exposure levels in children undergoing CT. • Adaptive statistical iterative reconstruction (ASIR) significantly increases SNR without impairing spatial resolution. • For abdomen and chest CT, ASIR allows at least a 30 % dose reduction.

  17. Intrinsic positive end-expiratory pressure during one-lung ventilation of patients with pulmonary hyperinflation. Influence of low respiratory rate with unchanged minute volume.

    Science.gov (United States)

    Szegedi, L L; Barvais, L; Sokolow, Y; Yernault, J C; d'Hollander, A A

    2002-01-01

    We measured lung mechanics and gas exchange during one-lung ventilation (OLV) of patients with chronic obstructive pulmonary disease, using three respiratory rates (RR) and unchanged minute volume. We studied 15 patients about to undergo lung surgery, during anaesthesia, and placed in the lateral position. Ventilation was with constant minute volume, inspiratory flow and FIO2. For periods of 15 min, RR of 5, 10, and 15 bpm were applied in a random sequence and recordings were made of lung mechanics and an arterial blood gas sample was taken. Data were analysed with the repeated measures ANOVA and paired t-test with Bonferroni correction. PaO2 changes were not significant. At the lowest RR, PaCO2 decreased (from 42 (SD 4) mm Hg at RR 15-41 (4) mm Hg at RR 10 and 39 (4) mm Hg at RR 5, P<0.01), and end-tidal carbon dioxide increased (from 33 (5) mm Hg at RR 15 to 35 (5) mm Hg at RR 10 and 36 (6) mm Hg at RR 5, P<0.01). Intrinsic positive end-expiratory pressure (PEEPi) was reduced even with larger tidal volumes (from 6 (4) cm H2O at RR 15-5 (4) cm H2O at RR 10, and 3 (3) cm H2O at RR 5, P<0.01), most probably caused by increased expiratory time at the lowest RR. A reduction in RR reduces PEEPi and hypercapnia during OLV in anaesthetized patients with chronic obstructive lung disease.

  18. Lateral rectal shielding reduces late rectal morbidity after high dose three-dimensional conformal radiation therapy for clinically localized prostate cancer: further evidence for a dose effect

    Energy Technology Data Exchange (ETDEWEB)

    Lee, W Robert; Hanks, Gerald E; Hanlon, Alexandra; Schultheiss, Timothy E

    1995-07-01

    Purpose: Using conventional treatment methods for the treatment of clinically localized prostate cancer central axis doses must be limited to 65-70 Gy to prevent significant damage to nearby normal tissues. A fundamental hypothesis of three-dimensional conformal radiation therapy (3DCRT) is that, by defining the target organ(s) accurately in three dimensions, it is possible to deliver higher doses to the target without a significant increase in normal tissue complications. This study examines whether this hypothesis holds true and whether a simple modification of treatment technique can reduce the incidence of late rectal morbidity in patients with prostate cancer treated with 3DCRT to minimum planning target volume (PTV) doses of 71-75 Gy. Materials and Methods: 257 patients with clinically localized prostate cancer completed 3DCRT by December 31, 1993 and received a minimum PTV dose of 71-75 Gy. The median follow-up time was 22 months (range 4-67 months) and 98% of patients had followup of longer than 12 months. The calculated dose at the center of the prostate was <74 Gy in 19 patients, 74-76 Gy in 206 patients and >76 Gy in 32 patients. Late rectal morbidity was graded according to the LENT scoring system. Eighty-eight consecutive patients were treated with a rectal block added to the lateral fields. In these patients the posterior margin from the prostate to the block edge was reduced from the standard 15 mm to 7.5 mm for the final 10 Gy which reduced the dose to portions of the anterior rectal wall by approximately 4-5 Gy. Estimates of rates for rectal morbidity were determined by Kaplan-Meier actuarial analyses. Differences in morbidity percentages were evaluated by the Pearson chi square test. Results: Grade 2-3 rectal morbidity developed in 46 of 257 patients (18%) and in the majority of cases consisted of rectal bleeding. No patient has developed grade 4 or 5 rectal morbidity. The actuarial rate of grade 2-3 morbidity is 22% at 24 months and the median

  19. Dead space and slope indices from the expiratory carbon dioxide tension-volume curve

    OpenAIRE

    Kars, Alice; Bogaard, Jan; Stijnen, Theo; Vries, J.; Verbraak, Anton; Hilvering, C.

    1997-01-01

    textabstractThe slope of phase 3 and three noninvasively determined dead space estimates derived from the expiratory carbon dioxide tension (PCO2) versus volume curve, including the Bohr dead space (VD,Bohr), the Fowler dead space (VD,Fowler) and pre-interface expirate (PIE), were investigated in 28 healthy control subjects, 12 asthma and 29 emphysema patients (20 severely obstructed and nine moderately obstructed) with the aim to establish diagnostic value. Because breath volume and frequenc...

  20. Transport of expiratory droplets in an aircraft cabin.

    Science.gov (United States)

    Gupta, Jitendra K; Lin, Chao-Hsin; Chen, Qingyan

    2011-02-01

    The droplets exhaled by an index patient with infectious disease such as influenza or tuberculosis may be the carriers of contagious agents. Indoor environments such as the airliner cabins may be susceptible to infection from such airborne contagious agents. The present investigation computed the transport of the droplets exhaled by the index patient seated in the middle of a seven-row, twin-aisle, fully occupied cabin using the CFD simulations. The droplets exhaled were from a single cough, a single breath, and a 15-s talk of the index patient. The expiratory droplets were tracked by using Lagrangian method, and their evaporation was modeled. It was found that the bulk airflow pattern in the cabin played the most important role on the droplet transport. The droplets were contained in the row before, at, and after the index patient within 30 s and dispersed uniformly to all the seven rows in 4 minutes. The total airborne droplet fraction reduced to 48, 32, 20, and 12% after they entered the cabin for 1, 2, 3, and 4 min, respectively, because of the ventilation from the environmental control system. It is critical to predict the risk of airborne infection to take appropriate measures to control and mitigate the risk. Most of the studies in past either assume a homogenous distribution of contaminants or use steady-state conditions. The present study instead provides information on the transient movement of the droplets exhaled by an index passenger in an aircraft cabin. These droplets may contain active contagious agents and can be potent enough to cause infection. The findings can be used by medical professionals to estimate the spatial and temporal distribution of risk of infection to various passengers in the cabin. © 2010 John Wiley & Sons A/S.

  1. Automatic exposure control in pediatric and adult multidetector CT examinations: A phantom study on dose reduction and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Papadakis, Antonios E.; Perisinakis, Kostas; Damilakis, John [Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 1352, Iraklion 71110, Crete (Greece)

    2008-10-15

    The aim of this study was to assess the potential of a modern x,y,z modulation-based automatic exposure control system (AEC) for dose reduction in pediatric and adult multidetector CT (MDCT) imaging and evaluate the quality of the images obtained. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-, 5-, 10-year old child, and adult were scanned with a MDCT scanner, equipped with a modern AEC system. Dose reduction (%DR) was calculated as the percentage difference of the mean modulated and the preset tube current-time product that is prescribed for standard head and body scan protocols. The effect of the tube potential and the orientation of the topogram acquisition on dose reduction were assessed. Image quality was evaluated on the basis of image noise and signal to noise ratio (SNR). The dose reduction values achieved in pediatric phantoms were remarkably lower than those achieved for the adult. The efficiency of the AEC is decreased at 80 kVp compared to higher tube potentials and for helical scans following an anterior posterior (AP-AEC) compared to a lateral (LAT-AEC) topogram acquisition. In AP-AEC scans, the dose reduction ranged between 4.7 and 34.7% for neonate, 15.4 and 30.9% for 1 year old, 3.1 and 26.7% for 5 years old, 1.2 and 58.7% for 10 years old, and 15.5 and 57.4% for adult. In LAT-AEC scans, the corresponding dose reduction ranged between 11.0 and 36.5%, 27.2 and 35.7%, 11.3 and 35.6%, 0.3 and 67.0%, and 15.0 and 61.7%, respectively. AP-AEC scans resulted in a 17.1% and 19.7% dose increase in the thorax of neonate and the pelvis of the 10-year old phantom, respectively. The variation in the measured noise among images obtained along the scanning z axis was lower in AEC activated compared to fixed milliamperes scans. However, image noise was significantly increased (P<.001) and SNR significantly decreased (P<.001) in most AEC activated compared to fixed milliamperes scans. In conclusion, AEC resulted in a (i

  2. Health-economic evaluation of three imaging strategies in patients with suspected colorectal liver metastases: Gd-EOB-DTPA-enhanced MRI vs. extracellular contrast media-enhanced MRI and 3-phase MDCT in Germany, Italy and Sweden

    International Nuclear Information System (INIS)

    Zech, C.J.; Grazioli, L.; Jonas, E.; Ekman, M.; Joensson, L.; Niebecker, R.; Kienbaum, S.; Gschwend, S.; Breuer, J.

    2009-01-01

    The purpose of this study was to perform an economic evaluation of hepatocyte-specific Gd-EOB-DTPA enhanced MRI (PV-MRI) compared to extracellular contrast-media-enhanced MRI (ECCM-MRI) and three-phase-MDCT as initial modalities in the work-up of patients with metachronous colorectal liver metastases. The economic evaluation was performed with a decision-tree model designed to estimate all aggregated costs depending on the initial investigation. Probabilities on the need for further imaging to come to a treatment decision were collected through interviews with 13 pairs of each a radiologist and a liver surgeon in Germany, Italy and Sweden. The rate of further imaging needed was 8.6% after initial PV-MRI, 18.5% after ECCM-MRI and 23.5% after MDCT. Considering the cost of all diagnostic work-up, intra-operative treatment changes and unnecessary surgery, a strategy starting with PV-MRI with 959 EUR was cost-saving compared to ECCM-MRI (1,123 EUR) and MDCT (1,044 EUR) in Sweden. In Italy and Germany, PV-MRI was cost-saving compared to ECCM-MRI and had total costs similar to MDCT. In conclusion, our results indicate that PV-MRI can lead to cost savings by improving pre-operative planning and decreasing intra-operative changes. The higher cost of imaging with PV-MRI is offset in such a scenario by lower costs for additional imaging and less intra-operative changes. (orig.)

  3. Diagnostic Value and Interreader Agreement of the Pancreaticolienal Gap in Pancreatic Cancer on MDCT.

    Directory of Open Access Journals (Sweden)

    Khoschy Schawkat

    Full Text Available The aim of this retrospective study was to evaluate the diagnostic value and measure interreader agreement of the pancreaticolienal gap (PLG in the assessment of imaging features of pancreatic carcinoma (PC on contrast-enhanced multi-detector computed tomography (CE-MDCT.CE-MDCT studies in the portal venous phase were retrospectively reviewed for 66 patients with PC. The age- and gender-matched control group comprised 103 healthy individuals. Three radiologists with different levels of experience independently measured the PLG (the minimum distance of the pancreatic tail to the nearest border of the spleen in the axial plane. The interreader agreement of the PLG and the receiver operating characteristic (ROC curve was used to calculate the accuracy of the technique.While the control group (n = 103 showed a median PLG of 3 mm (Range: 0 - 39mm the PC patients had a significantly larger PLG of 15mm (Range: 0 - 53mm(p 12 mm for PC, with a sensitivity of 58.2% (95% CI = 45.5-70.1, specificity of 84.0% (95% CI = 75.6-90.4 and an area under the ROC curve of 0.714 (95% CI = 0.641 to 0.780. The mean interreader agreement showed correlation coefficient r of 0.9159. The extent of the PLG did not correlate with tumor stage but did correlate with pancreatic density (fatty involution and age, the density decreased by 4.1 HU and the PLG increased by 0.8 mm within every 10 y.The significant interreader agreement supports the use of the PLG as a characterizing feature of pancreatic cancer independent of the tumor stage on an axial plane. The increase in the PLG with age may represent physiological atrophy of the pancreatic tail.

  4. Lateralized odontoid in plain film radiography. Sign of fractures? A comparison study with MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Keller, S.; Bieck, K.; Karul, M.; Schoennagel, B.; Adam, G.; Habermann, C.; Yamamura, J. [University Hospital Hamburg Eppendorf (Germany). Dept. of Diagnostic and Interventional Radiology

    2015-09-15

    To evaluate X-ray standards for the detection of odontoid fractures. Summary of background data: Cervical spine fractures are a common finding in emergency medicine, accounting for 1 - 3 % of injuries. Involvement of the C1 / C2 complex is found in 25 % of cases, affecting the odontoid peg in 55 - 80 %. Regarding the consequences of missed fractures, radiographic techniques built the groundwork for further treatment procedures. As standardized X-ray measurements have not been established, the incidence of unrecognized cervical spine fracture is expected to be up to 20 %. The establishment of X-ray-based guidelines is also limited by the presumed low specificity and sensitivity of distance measurements caused by rotational distortion which leads to a rising popularity of CT. 79 (age 60 ± 26 yrs) patients with lateralization of the odontoid process on conventional plain film radiography (anteroposterior, lateral, and open mouth odontoid process view projection) were examined. The distance between the odontoid process and lateral mass of C1, angles of vertical odontoid line and basis of C2 were measured in the ap view. In the lateral view, dorsal alignment and atlantodental distance were assessed. MDCT examinations were used as a reference. Discriminatory power test was applied to assess significance. 8/79 (10.1 %) odontoid process fractures were found. Diagnosis was achieved on conventional radiographs in 6 patients. Neither distance and angle measurements between odontoid and C1 nor the dorsal alignment of the vertebral bodies differed significantly between healthy and affected patients. Decentralization of the odontoid process is not necessarily an indirect sign for its fracture. In patients with suspected injury of the odontoid process, an MDCT scan might be the method of choice to rule out a fracture.

  5. The usefulness of Al face block fabrication for reducing exposure dose of thyroid glands in mammography

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Eun Ae [Dept. of Diagnostic Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of); Lee, In Ja [Dept. of Radiologic Technology, Dongnam Health College, Suwon (Korea, Republic of)

    2013-03-15

    Currently, there are many studies being conducted around the world to reduce exposure dose to radiation for patients to receive medical treatments in a safe environment. We developed and fabricated of this shield that the patients are protected from the radiation and are need of safety control during breast imaging. In this study, for breast imaging, GE Senography 2000D were used and set at SID 65 cm, 28 kVp, and 63 mAs. The measuring instrument was Flukes Victoreen 6000-529. And we performed Face Block on with 30 patients. The chamber on the actual thyroid glands to take CC and MLO and measure the dosage before and after wearing the Face Block. For the results, after wearing the Face Block, exposure was decreased by 53.8%-100% and 65.8% in average in CC View and by 50%-100% and 60.7% in average in MLO View. The development of the Face Block that practically decreased the exposure dose of thyroid glands, crystalline eyes during breast imaging and reduced the patients anxiety during breast imaging. The Face Block is expected to improve patients satisfaction and contribute to reducing patients exposure dose, but more efforts should be made to reduce exposure dose to medical radiation.

  6. Analysis of technologies and experiences for reducing occupational radiation dose and study for applying to regulations

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Joo Hyun; Park, Moon Soo; Lee, Un Jang; Song, Jae Hyuk; Kim, Byeong Soo; Kim, Chong Uk [Seoul National Univ., Seoul (Korea, Republic of)

    2003-01-15

    To reduce Occupational Radiation Dose (ORD) effectively and enhance the radiological safety, the comprehensive assessment of the experiences to reduce ORD should be made by regulatory body as well as utilities. Hence, the objective of this study is to assess the experiences for reducing ORD from the regulatory viewpoint. With the research objective, the followings are performed in this research; analysis of occupational dose trends at domestic and foreign NPPs, identification of the effective technologies for reducing ORD, examination of the effects of the technologies for reducing ORD, derivation of the regulatory means for implementing he research results. From this study, the regulatory means for effective reduction of ORD are derived. Hence, the results can be utilized as a basic materials for ALARA requirements.

  7. Automated diagnosis of interstitial lung diseases and emphysema in MDCT imaging

    Science.gov (United States)

    Fetita, Catalin; Chang Chien, Kuang-Che; Brillet, Pierre-Yves; Prêteux, Françoise

    2007-09-01

    Diffuse lung diseases (DLD) include a heterogeneous group of non-neoplasic disease resulting from damage to the lung parenchyma by varying patterns of inflammation. Characterization and quantification of DLD severity using MDCT, mainly in interstitial lung diseases and emphysema, is an important issue in clinical research for the evaluation of new therapies. This paper develops a 3D automated approach for detection and diagnosis of diffuse lung diseases such as fibrosis/honeycombing, ground glass and emphysema. The proposed methodology combines multi-resolution 3D morphological filtering (exploiting the sup-constrained connection cost operator) and graph-based classification for a full characterization of the parenchymal tissue. The morphological filtering performs a multi-level segmentation of the low- and medium-attenuated lung regions as well as their classification with respect to a granularity criterion (multi-resolution analysis). The original intensity range of the CT data volume is thus reduced in the segmented data to a number of levels equal to the resolution depth used (generally ten levels). The specificity of such morphological filtering is to extract tissue patterns locally contrasting with their neighborhood and of size inferior to the resolution depth, while preserving their original shape. A multi-valued hierarchical graph describing the segmentation result is built-up according to the resolution level and the adjacency of the different segmented components. The graph nodes are then enriched with the textural information carried out by their associated components. A graph analysis-reorganization based on the nodes attributes delivers the final classification of the lung parenchyma in normal and ILD/emphysematous regions. It also makes possible to discriminate between different types, or development stages, among the same class of diseases.

  8. MDCT Anatomic Assessment of Right Inferior Phrenic Artery Origin Related to Potential Supply to Hepatocellular Carcinoma and its Embolization

    International Nuclear Information System (INIS)

    Basile, Antonio; Tsetis, Dimitrios; Montineri, Arturo; Puleo, Stefano; Massa Saluzzo, Cesare; Runza, Giuseppe; Coppolino, Francesco; Ettorre, Giovanni Carlo; Patti, Maria Teresa

    2008-01-01

    Purpose. To prospectively assess the anatomic variation of the right inferior phrenic artery (RIPA) origin with multidetector computed tomography (MDCT) scans in relation to the technical and angiographic findings during transcatheter arterial embolization of hepatocellular carcinoma (HCC). Methods. Two hundred patients with hepatocellular carcinomas were examined with 16-section CT during the arterial phase. The anatomy of the inferior phrenic arteries was recorded, with particular reference to their origin. All patients with subcapsular HCC located at segments VII and VIII underwent arteriography of the RIPA with subsequent embolization if neoplastic supply was detected. Results. The RIPA origin was detected in all cases (sensitivity 100%), while the left inferior phrenic artery origin was detected in 187 cases (sensitivity 93.5%). RIPAs originated from the aorta (49%), celiac trunk (41%), right renal artery (5.5%), left gastric artery (4%), and proper hepatic artery (0.5%), with 13 types of combinations with the left IPA. Twenty-nine patients showed subcapsular HCCs in segments VII and VIII and all but one underwent RIPA selective angiography, followed by embolization in 7 cases. Conclusion. MDCT assesses well the anatomy of RIPAs, which is fundamental for planning subsequent cannulation and embolization of extrahepatic RIPA supply to HCC

  9. Efficacy of reduced dose of intravitreal triamcinolone acetonide in a case of active serpiginous choroiditis

    Directory of Open Access Journals (Sweden)

    Avirupa Ghose

    2016-01-01

    Full Text Available Active serpiginous choroiditis (SC is a vision-threatening condition which requires intensive treatment using corticosteroids and/or immunosuppressives, especially if the lesions are involving or encroaching on the macula. Use of oral and intravenous high-dose steroids are contraindicated in uncontrolled diabetics. Intravitreal steroid delivers a localized dose in such situations. This case report highlights the efficacy of reduced dose of intravitreal triamcinolone acetonide (2 mg in the treatment of active SC.

  10. The evaluation of the radiation dose and image quality through the change of the tube voltage in cerebral CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Won; Jung, Kang Kyo; Cho, Pyong Kon [Radiological Science, Catholic University of Daegu, Daegu (Korea, Republic of)

    2015-06-15

    To image diagnosis in neurovascular diseases using Multi-Detector Computed Tomography (MDCT), injected the same contrast material when inspecting Brain Computed Tomography Angiography (BCTA) to examine radiation dose and Image quality on changing Cerebral Artery CT number by tube voltage. Executed an examination with same condition[Beam Collimation 128 x 0.6 mm, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0 mm, Increment 5.0 mm, Delay Time 3.0 sec, Care Dose 4D (Demension ; D)] except for tube voltage on 50 call patients for BCTA and divided them into two groups (25 people for a group, group A: 80, group B: 120 kVp). From all the acquired images, set a ROI(Region of Interest) on four spots such as left cerebral artery, right cerebral artery, posterior cerebral artery and cerebral parenchyma to compare quantitative evaluation, qualitative evaluation and effective dose after measuring CT number value from Picture Archiving Communications System(PACS). Evaluating images with CT number acquired from BCTA examination, images with 80 kVp was 18 % higher in Signal to Noise Ratio and 19 % in Contrast to Noise Ratio than those with 120 kVp. It was seen that expose dose was decreased by over 50 % with tube voltage 80 kVp than with 120 kVp. Group A (25 patients) was examination with tube voltage 80 kVp while group B with 120 kVp to examine radiation dose and Image quality. It is considered effective to inspect with lower tube voltage than with conventional high kVp, which can reduce radiation dose without any affect on diagnosis.

  11. Development of Computational Procedure for Assessment of Patient Dose in Multi-Detector Computed Tomography

    International Nuclear Information System (INIS)

    Park, Dong Wook

    2007-02-01

    Technological development to improve the quality and speed with which images are obtained have fostered the growth of frequency and collective effective dose of CT examination. Especially, High-dose x-ray technique of CT has increased in the concern of patient dose. However CTDI and DLP in CT dosimetry leaves something to be desired to evaluate patient dose. And even though the evaluation of effective dose in CT practice is required for comparison with other radiography, it's not sufficient to show any estimation because it's not for medical purpose. Therefore the calculation of effective dose in CT procedure is needed for that purpose. However modelling uncertainties will be due to insufficient information from manufacturing tolerances. Therefore the purpose of this work is development of computational procedure for assessment of patient dose through the experiment for getting essential information in MDCT. In order to obtain exact absorbed dose, normalization factors must be created to relate simulated dose values with CTDI air measurement. The normalization factors applied to the calculation of CTDI 100 using axial scanning and organ effective dose using helical scanning. The calculation of helical scanning was compared with the experiment of Groves et al.(2004). The result has a about factor 2 of the experiment. It seems because AEC is not simulated. In several studies, when AEC applied to a CT examination, approximately 20-30% dose reduction was appeared. Therefore the study of AEC simulation should be added and modified

  12. TU-CD-BRA-11: Application of Bone Suppression Technique to Inspiratory/expiratory Chest Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, R; Sanada, S [Kanazawa University, Kanazawa, Ishikawa (Japan); Sakuta, K; Kawashima, H [Kanazawa University Hospital, Kanazawa, Ishikawa (Japan); Kishitani, Y [TOYO Corporation, Chuoh-ku, Tokyo (Japan)

    2015-06-15

    Purpose: The bone suppression technique based on advanced image processing can suppress the conspicuity of bones on chest radiographs, creating soft tissue images normally obtained by the dual-energy subtraction technique. This study was performed to investigate the usefulness of bone suppression technique in quantitative analysis of pulmonary function in inspiratory/expiratory chest radiography. Methods: Commercial bone suppression image processing software (ClearRead; Riverain Technologies) was applied to paired inspiratory/expiratory chest radiographs of 107 patients (normal, 33; abnormal, 74) to create corresponding bone suppression images. The abnormal subjects had been diagnosed with pulmonary diseases, such as pneumothorax, pneumonia, emphysema, asthma, and lung cancer. After recognition of the lung area, the vectors of respiratory displacement were measured in all local lung areas using a cross-correlation technique. The measured displacement in each area was visualized as displacement color maps. The distribution pattern of respiratory displacement was assessed by comparison with the findings of lung scintigraphy. Results: Respiratory displacement of pulmonary markings (soft tissues) was able to be quantified separately from the rib movements on bone suppression images. The resulting displacement map showed a left-right symmetric distribution increasing from the lung apex to the bottom region of the lung in many cases. However, patients with ventilatory impairments showed a nonuniform distribution caused by decreased displacement of pulmonary markings, which were confirmed to correspond to area with ventilatory impairments found on the lung scintigrams. Conclusion: The bone suppression technique was useful for quantitative analysis of respiratory displacement of pulmonary markings without any interruption of the rib shadows. Abnormal areas could be detected as decreased displacement of pulmonary markings. Inspiratory/expiratory chest radiography combined

  13. Head CT: Image quality improvement with ASIR-V using a reduced radiation dose protocol for children.

    Science.gov (United States)

    Kim, Hyun Gi; Lee, Ho-Joon; Lee, Seung-Koo; Kim, Hyun Ji; Kim, Myung-Joon

    2017-09-01

    To investigate the quality of images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V), using pediatric head CT protocols. A phantom was scanned at decreasing 20% mA intervals using our standard pediatric head CT protocols. Each study was then reconstructed at 10% ASIR-V intervals. After the phantom study, we reduced mA by 10% in the protocol for ASIR-V and by 30% in the protocol for 3- to 15-year-old patients and applied 40% ASIR-V. Increasing the percentage of ASIR-V resulted in lower noise and higher contrast-to-noise ratio (CNR) and preserved spatial resolution in the phantom study. Compared to a conventional-protocol, reduced-dose protocol with ASIR-V achieved 12.8% to 34.0% of dose reduction and showed images of lower noise (9.22 vs. 10.73, P = 0.043) and higher CNR in different levels (centrum semiovale, 2.14 vs. 1.52, P = 0.003; basal ganglia, 1.46 vs. 1.07, P = 0.001; and cerebellum, 2.18 vs. 1.33, P ASIR-V. Use of ASIR-V allowed a 12.8% to 34.0% dose reduction in each age group with potential to improve image quality. • It is possible to reduce radiation dose and improve image quality with ASIR-V. • We improved noise and CNR and decreased radiation dose. • Sharpness improved with ASIR-V. • Total radiation dose was decreased by 12.8% to 34.0%.

  14. Accuracy of MDCT in the preoperative definition of Peritoneal Cancer Index (PCI) in patients with advanced ovarian cancer who underwent peritonectomy and hyperthermic intraperitoneal chemotherapy (HIPEC).

    Science.gov (United States)

    Mazzei, Maria Antonietta; Khader, Leila; Cirigliano, Alfredo; Cioffi Squitieri, Nevada; Guerrini, Susanna; Forzoni, Beatrice; Marrelli, Daniele; Roviello, Franco; Mazzei, Francesco Giuseppe; Volterrani, Luca

    2013-12-01

    To evaluate the accuracy of MDCT in the preoperative definition of Peritoneal Cancer Index (PCI) in patients with advanced ovarian cancer who underwent a peritonectomy and hyperthermic intraperitoneal chemotherapy (HIPEC) after neoadjuvant chemotherapy to obtain a pre-surgery prognostic evaluation and a prediction of optimal cytoreduction surgery. Pre-HIPEC CT examinations of 43 patients with advanced ovarian cancer after neoadjuvant chemotherapy were analyzed by two radiologists. The PCI was scored according to the Sugarbaker classification, based on lesion size and distribution. The results were compared with macroscopic and histologic data after peritonectomy and HIPEC. To evaluate the accuracy of MDCT to detect and localize peritoneal carcinomatosis, both patient-level and regional-level analyses were conducted. A correlation between PCI CT and histologic values for each patient was searched according to the PCI grading. Considering the patient-level analysis, CT shows a sensitivity, specificity, PPV, NPV, and an accuracy in detecting the peritoneal carcinomatosis of 100 %, 40 %, 93 % 100 %, and 93 %, respectively. Considering the regional level analysis, a sensitivity, specificity, PPV, NPV, and diagnostic accuracy of 72 %, 80 %, 66 %, 84 %, and 77 %, respectively were obtained for the correlation between CT and histology. Our results encourage the use of MDCT as the only technique sufficient to select patients with peritoneal carcinomatosis for cytoreductive surgery and HIPEC on the condition that a CT examination will be performed using a dedicated protocol optimized to detect minimal peritoneal disease and CT images will be analyzed by an experienced reader.

  15. Agricultural measures to reduce radiation doses to man caused by severe nuclear accidents

    International Nuclear Information System (INIS)

    Dorp, F. van; Eleveld, R.; Frissel, M.J.

    1981-01-01

    Agricultural land and products may become contaminated after a severe nuclear accident. If radiation doses to man caused by the ingestion of contaminated agricultural products from such areas will be unacceptably high, measures to reduce this radiation dose will have to be taken. Radiation doses to man can be estimated by using models which describe quantitatively the transfer of radionuclides through the biosphere. The following processes and pathways are described in this study: accidental releases into atmospheric environments and subsequent nearby deposition; contamination of crops by direct deposition and the subsequent short term pathway (e.g. grass-cow-milk-man); contamination of soil and the subsequent long term pathway (e.g. soil-crop-man, soil-grass-cattle-milk/meat-man). Depending on the degree of contamination and on the estimated radiation doses to man, various measures are advised. (Auth.)

  16. Deep breathing exercises with positive expiratory pressure in patients with multiple sclerosis - a randomized controlled trial.

    Science.gov (United States)

    Westerdahl, Elisabeth; Wittrin, Anna; Kånåhols, Margareta; Gunnarsson, Martin; Nilsagård, Ylva

    2016-11-01

    Breathing exercises with positive expiratory pressure are often recommended to patients with advanced neurological deficits, but the potential benefit in multiple sclerosis (MS) patients with mild and moderate symptoms has not yet been investigated in randomized controlled trials. To study the effects of 2 months of home-based breathing exercises for patients with mild to moderate MS on respiratory muscle strength, lung function, and subjective breathing and health status outcomes. Forty-eight patients with MS according to the revised McDonald criteria were enrolled in a randomized controlled trial. Patients performing breathing exercises (n = 23) were compared with a control group (n = 25) performing no breathing exercises. The breathing exercises were performed with a positive expiratory pressure device (10-15 cmH 2 O) and consisted of 30 slow deep breaths performed twice a day for 2 months. Respiratory muscle strength (maximal inspiratory and expiratory pressure at the mouth), spirometry, oxygenation, thoracic excursion, subjective perceptions of breathing and self-reported health status were evaluated before and after the intervention period. Following the intervention, there was a significant difference between the breathing group and the control group regarding the relative change in lung function, favoring the breathing group (vital capacity: P < 0.043; forced vital capacity: P < 0.025). There were no other significant differences between the groups. Breathing exercises may be beneficial in patients with mild to moderate stages of MS. However, the clinical significance needs to be clarified, and it remains to be seen whether a sustainable effect in delaying the development of respiratory dysfunction in MS can be obtained. © 2015 The Authors. The Clinical Respiratory Journal published by John Wiley & Sons Ltd.

  17. Editorial to: Baseline MDCT findings after prosthetic heart valve implantation provide important complementary information to echocardiography for follow-up purposes by Sucha et al

    Energy Technology Data Exchange (ETDEWEB)

    Peeters, F.E.C.M. [Maastricht University Medical Center, Department of Cardiology, Maastricht (Netherlands); Kietselaer, B.L.J.H. [Maastricht University Medical Center, Department of Cardiology, Maastricht (Netherlands); Maastricht University Medical Center, Department of Radiology, Maastricht (Netherlands)

    2016-04-15

    Over the last years a growing number of prosthetic heart valve (PHV) implantation procedures have been performed in sequence with the aging of the population and improving surgical techniques. Currently, echocardiography is the most important tool in the follow-up and evaluation of complications associated with the PHV (pannus, thrombus, endocarditis). However, echocardiographic examination of PHV associated disease may be hampered by poor acoustic window or scatter artefacts caused by the PHV. PHV related disease such as endocarditis is related with a poor prognosis, especially when complications such as periannular abscess formation occurs. Early treatment of PHV associated disease improves prognosis. Therefore, an unmet clinical need for early detection of complications exists. In the evaluation of PHV (dys)function, multidetector-row computed tomography (MDCT) has shown to be of additive value. A necessity for MDCT to be implemented in daily practice is to be able to distinguish between normal and pathological features. (orig.)

  18. Editorial to: Baseline MDCT findings after prosthetic heart valve implantation provide important complementary information to echocardiography for follow-up purposes by Sucha et al

    International Nuclear Information System (INIS)

    Peeters, F.E.C.M.; Kietselaer, B.L.J.H.

    2016-01-01

    Over the last years a growing number of prosthetic heart valve (PHV) implantation procedures have been performed in sequence with the aging of the population and improving surgical techniques. Currently, echocardiography is the most important tool in the follow-up and evaluation of complications associated with the PHV (pannus, thrombus, endocarditis). However, echocardiographic examination of PHV associated disease may be hampered by poor acoustic window or scatter artefacts caused by the PHV. PHV related disease such as endocarditis is related with a poor prognosis, especially when complications such as periannular abscess formation occurs. Early treatment of PHV associated disease improves prognosis. Therefore, an unmet clinical need for early detection of complications exists. In the evaluation of PHV (dys)function, multidetector-row computed tomography (MDCT) has shown to be of additive value. A necessity for MDCT to be implemented in daily practice is to be able to distinguish between normal and pathological features. (orig.)

  19. The leaded apron revisited: does it reduce gonadal radiation dose in dental radiology

    Energy Technology Data Exchange (ETDEWEB)

    Wood, R.E.; Harris, A.M.; van der Merwe, E.J.; Nortje, C.J. (Ontario Cancer Institute, Princess Margaret Hospital, Toronto (Canada))

    1991-05-01

    A tissue-equivalent anthropomorphic human phantom was used with a lithium fluoride thermoluminescent dosimetry system to evaluate the radiation absorbed dose to the ovarian and testicular region during dental radiologic procedures. Measurements were made with and without personal lead shielding devices consisting of thyroid collar and apron of 0.25 mm lead thickness equivalence. The radiation absorbed dose with or without lead shielding did not differ significantly from control dosimeters in vertex occlusal and periapical views (p greater than 0.05). Personal lead shielding devices did reduce gonadal dose in the case of accidental exposure (p less than 0.05). A leaded apron of 0.25 mm lead thickness equivalent was permeable to radiation in direct exposure testing.

  20. The leaded apron revisited: does it reduce gonadal radiation dose in dental radiology

    International Nuclear Information System (INIS)

    Wood, R.E.; Harris, A.M.; van der Merwe, E.J.; Nortje, C.J.

    1991-01-01

    A tissue-equivalent anthropomorphic human phantom was used with a lithium fluoride thermoluminescent dosimetry system to evaluate the radiation absorbed dose to the ovarian and testicular region during dental radiologic procedures. Measurements were made with and without personal lead shielding devices consisting of thyroid collar and apron of 0.25 mm lead thickness equivalence. The radiation absorbed dose with or without lead shielding did not differ significantly from control dosimeters in vertex occlusal and periapical views (p greater than 0.05). Personal lead shielding devices did reduce gonadal dose in the case of accidental exposure (p less than 0.05). A leaded apron of 0.25 mm lead thickness equivalent was permeable to radiation in direct exposure testing

  1. Effects of nasal positive expiratory pressure on dynamic hyperinflation and 6-minute walk test in patients with COPD.

    Science.gov (United States)

    Wibmer, Thomas; Rüdiger, Stefan; Heitner, Claudia; Kropf-Sanchen, Cornelia; Blanta, Ioanna; Stoiber, Kathrin M; Rottbauer, Wolfgang; Schumann, Christian

    2014-05-01

    Dynamic hyperinflation is an important target in the treatment of COPD. There is increasing evidence that positive expiratory pressure (PEP) could reduce dynamic hyperinflation during exercise. PEP application through a nasal mask and a flow resistance device might have the potential to be used during daily physical activities as an auxiliary strategy of ventilatory assistance. The aim of this study was to determine the effects of nasal PEP on lung volumes during physical exercise in patients with COPD. Twenty subjects (mean ± SD age 69.4 ± 6.4 years) with stable mild-to-severe COPD were randomized to undergo physical exercise with nasal PEP breathing, followed by physical exercise with habitual breathing, or vice versa. Physical exercise was induced by a standard 6-min walk test (6 MWT) protocol. PEP was applied by means of a silicone nasal mask loaded with a fixed-orifice flow resistor. Body plethysmography was performed immediately pre-exercise and post-exercise. Differences in mean pre- to post-exercise changes in total lung capacity (-0.63 ± 0.80 L, P = .002), functional residual capacity (-0.48 ± 0.86 L, P = .021), residual volume (-0.56 ± 0.75 L, P = .004), S(pO2) (-1.7 ± 3.4%, P = .041), and 6 MWT distance (-30.8 ± 30.0 m, P = .001) were statistically significant between the experimental and the control interventions. The use of flow-dependent expiratory pressure, applied with a nasal mask and a PEP device, might promote significant reduction of dynamic hyperinflation during walking exercise. Further studies are warranted addressing improvements in endurance performance under regular application of nasal PEP during physical activities.

  2. Experimental Study of Dispersion and Deposition of Expiratory Aerosols in Aircraft Cabins and Impact on Infectious Disease Transmission

    DEFF Research Database (Denmark)

    To, G.N.S.; Wan, M.P.; Chao, C.Y.H.

    2009-01-01

    The dispersion and deposition characteristics of polydispersed expiratory aerosols were investigated in an aircraft cabin mockup to study the transmission of infectious diseases. The airflow was characterized by particle image velocimetry (PIV) measurements. Aerosol dispersionwas measured...

  3. Diagnostic performance of reduced-dose CT with a hybrid iterative reconstruction algorithm for the detection of hypervascular liver lesions: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Nakamoto, Atsushi; Tanaka, Yoshikazu; Juri, Hiroshi; Nakai, Go; Narumi, Yoshifumi [Osaka Medical College, Department of Radiology, Takatsuki, Osaka (Japan); Yoshikawa, Shushi [Osaka Medical College Hospital, Central Radiology Department, Takatsuki, Osaka (Japan)

    2017-07-15

    To investigate the diagnostic performance of reduced-dose CT with a hybrid iterative reconstruction (IR) algorithm for the detection of hypervascular liver lesions. Thirty liver phantoms with or without simulated hypervascular lesions were scanned with a 320-slice CT scanner with control-dose (40 mAs) and reduced-dose (30 and 20 mAs) settings. Control-dose images were reconstructed with filtered back projection (FBP), and reduced-dose images were reconstructed with FBP and a hybrid IR algorithm. Objective image noise and the lesion to liver contrast-to-noise ratio (CNR) were evaluated quantitatively. Images were interpreted independently by 2 blinded radiologists, and jackknife alternative free-response receiver-operating characteristic (JAFROC) analysis was performed. Hybrid IR images with reduced-dose settings (both 30 and 20 mAs) yielded significantly lower objective image noise and higher CNR than control-dose FBP images (P <.05). However, hybrid IR images with reduced-dose settings had lower JAFROC1 figure of merit than control-dose FBP images, although only the difference between 20 mAs images and control-dose FBP images was significant for both readers (P <.01). An aggressive reduction of the radiation dose would impair the detectability of hypervascular liver lesions, although objective image noise and CNR would be preserved by a hybrid IR algorithm. (orig.)

  4. Changes in Cross-Sectional Area and Transverse Diameter of the Heart on Inspiratory and Expiratory Chest CT: Correlation with Changes in Lung Size and Influence on Cardiothoracic Ratio Measurement.

    Directory of Open Access Journals (Sweden)

    Hayato Tomita

    Full Text Available The aim of this study was to investigate physiological changes in cardiac area and diameters between inspiratory and expiratory chest computed tomography (CT, and to assess their correlation with lung size change and influence on cardiothoracic ratio (CTR measurements.The institutional review board of our institution approved this study, and informed consent was waived. Forty-three subjects underwent inspiratory and expiratory chest CT as part of routine clinical care. On both inspiratory and expiratory scans, lung volumes and maximum lung diameters (transverse and vertical directions were measured. The maximum cardiac cross-sectional area (CSA and the maximum transverse cardiac diameter were measured on both scans, and the CT-based CTR was calculated. Changes in the lung and cardiac measurements were expressed as the expiratory/inspiratory (E/I ratios. Comparisons between inspiratory and expiratory measurements were made by the Wilcoxon signed-rank test. Correlations between the E/I ratios of lung and heart measurements were evaluated by Spearman's rank correlation analysis.Cardiac CSA and transverse cardiac diameter was significantly larger on expiratory than on inspiratory CT (p < 0.0001. Significant negative correlations were found between the E/I ratios of these cardiac measurements and the E/I ratios of lung volume and vertical lung diameter (p < 0.01. CT-based CTR was significantly larger on expiration than on inspiration (p < 0.0001.Heart size on chest CT depends on the phase of ventilation, and is correlated with changes in lung volume and craniocaudal lung diameter. The CTR is also significantly influenced by ventilation.

  5. Nebulized hypertonic saline via positive expiratory pressure versus via jet nebulizer in patients with severe cystic fibrosis.

    LENUS (Irish Health Repository)

    O'Connell, Oisin J

    2011-06-01

    Nebulized hypertonic saline is a highly effective therapy for patients with cystic fibrosis (CF), yet 10% of patients are intolerant of hypertonic saline administered via jet nebulizer. Positive expiratory pressure (PEP) nebulizers splint open the airways and offers a more controlled rate of nebulization.

  6. Positive expiratory pressure in patients with chronic obstructive pulmonary disease--a systematic review.

    Science.gov (United States)

    Fagevik Olsén, Monika; Westerdahl, Elisabeth

    2009-01-01

    Breathing exercises against a resistance during expiration are often used as treatment for patients with chronic obstructive pulmonary disease (COPD). Controversy still exists regarding the clinical application and efficacy. The aim of this systematic review was to determine the effects of chest physiotherapy techniques with positive expiratory pressure (PEP) for the prevention and treatment of pulmonary impairment in adults with COPD. The review was conducted on randomised, controlled clinical trials in which breathing exercises with positive expiratory pressure were compared with other chest physical therapy techniques or with no treatment, in adult patients with COPD. A computer-assisted literature search of available databases from 1970 to January 2008 was performed. Two reviewers extracted data independently and assessed the trials systematically with an instrument for measuring methodological quality. In total, 11 trials met the inclusion criteria, of which 5 reached an adequate level of internal validity. Several kinds of PEP techniques with a diversity of intensities and durations of treatment have been evaluated with different outcome measures and follow-up periods. Benefits of PEP were found in isolated outcome measures in separate studies with a follow-up period <1 month. Concerning long-term effects, the results are contradictory. Prior to widespread prescription of long-term PEP treatment, more research is required to establish the benefit of the technique in patients with COPD. (c) 2008 S. Karger AG, Basel.

  7. Metallic artifacts from internal scaphoid fracture fixation screws: comparison between C-arm flat-panel, cone-beam, and multidetector computed tomography.

    Science.gov (United States)

    Finkenstaedt, Tim; Morsbach, Fabian; Calcagni, Maurizio; Vich, Magdalena; Pfirrmann, Christian W A; Alkadhi, Hatem; Runge, Val M; Andreisek, Gustav; Guggenberger, Roman

    2014-08-01

    The aim of this study was to compare image quality and extent of artifacts from scaphoid fracture fixation screws using different computed tomography (CT) modalities and radiation dose protocols. Imaging of 6 cadaveric wrists with artificial scaphoid fractures and different fixation screws was performed in 2 screw positions (45° and 90° orientation in relation to the x/y-axis) using multidetector CT (MDCT) and 2 flat-panel CT modalities, C-arm flat-panel CT (FPCT) and cone-beam CT (CBCT), the latter 2 with low and standard radiation dose protocols. Mean cartilage attenuation and metal artifact-induced absolute Hounsfield unit changes (= artifact extent) were measured. Two independent radiologists evaluated different image quality criteria using a 5-point Likert-scale. Interreader agreements (Cohen κ) were calculated. Mean absolute Hounsfield unit changes and quality ratings were compared using Friedman and Wilcoxon signed-rank tests. Artifact extent was significantly smaller for MDCT and standard-dose FPCT compared with CBCT low- and standard-dose acquisitions (all P 0.05). Both MDCT and FPCT standard-dose protocols showed equal ratings for screw bone interface, fracture line, and trabecular bone evaluation (P = 0.06, 0.2, and 0.2, respectively) and performed significantly better than FPCT low- and CBCT low- and standard-dose acquisitions (all P < 0.05). Good interreader agreement was found for image quality comparisons (Cohen κ = 0.76-0.78). Both MDCT and FPCT standard-dose acquisition showed comparatively less metal-induced artifacts and better overall image quality compared with FPCT low-dose and both CBCT acquisitions. Flat-panel CT may provide sufficient image quality to serve as a versatile CT alternative for postoperative imaging of internally fixated wrist fractures.

  8. Reduced oxygen enhancement ratio at low doses

    International Nuclear Information System (INIS)

    Palcic, B.; Skarsgard, L.D.

    1984-01-01

    The oxygen depletion rate in cell suspensions was measured using a Clark electrode. It was found that under experimental conditions used in this laboratory for hypoxic irradiations, the oxygen levels before the start of irradiation are always below 0.1μm, the levels which could give any significant enhancement to radiation inactivation by x-rays. The measured O/sub 2/ depletion rates were comparable to those reported in the literature. Chinese hamster cells (CHO) were made hypoxic by gas exchange, combined with metabolic consumption of oxygen by cells at 37 0 C. Full survival curves were determined in the dose range 0 to 3Gy using the low dose survival assay. The results confirmed the authors' earlier finding that the OER decreases at low doses. The authors therefore believe that the dose-dependent OER is a true radiobiological phenomenon and not an artifact of the experimental method used in the low dose survival assay

  9. Peak expiratory flow rate in healthy children aged 6-17 years

    DEFF Research Database (Denmark)

    Høst, A; Høst, A H; Ibsen, T

    1994-01-01

    Peak expiratory flow rate (PEFR) was measured in a cross-sectional study in 861 healthy Danish schoolchildren aged 6-17 years using a Mini Wright peak flowmeter. We found a strong correlation between PEFR and height, age and sex. The results were comparable with those from previous studies using...... a Wright peak flowmeter. The equation for prediction of PEFR in boys was calculated as (3.8 x height) + (10.6 x age) - 313.2 (p age) - 143.9 (p ... coefficient in this large sample. Among healthy children without previous asthma, earlier episodes of recurrent wheezing were reported in 8.8% and a significantly lower PEFR was found in this group....

  10. MDCT of primary, locally recurrent, and metastatic duodenal gastrointestinal stromal tumours (GISTs): A single institution study of 25 patients with review of literature

    International Nuclear Information System (INIS)

    Cheng, J.M.; Tirumani, S.H.; Shinagare, A.B.; Jagannathan, J.P.; Hornick, J.L.; Raut, C.P.; Ramaiya, N.H.

    2014-01-01

    Aim: To describe the multidetector computed tomography (MDCT) features of primary, locally recurrent, and metastatic duodenal gastrointestinal stromal tumours (GISTs). Materials and methods: In this institutional review board-approved, Health Insurance Portability and Accountability Act of 1996 (HIPAA)-compliant, retrospective study, 25 patients [13 men, 12 women; mean age 56 years (34–74 years)] with histopathologically confirmed duodenal GISTs seen at Dana Farber Cancer Institute and Brigham and Women's Hospital from December 1999 to October 2009 were identified. The MDCT of primary tumours in six patients and follow-up imaging in all the 25 patients was reviewed by two radiologists in consensus. Electronic medical records were reviewed to document the clinical characteristics and management. Results: The mean size of the primary tumour was 3.7 cm (range 2.5–5.6 cm). Three of six primary tumours were in the second and third portions of the duodenum, one in the third portion, one in the third and fourth portions, and one in the fourth portion. Three of six of the tumours were exophytic, two were both exophytic and intraluminal, and one was intramural. The tumours were well-circumscribed, round or oval masses, with few lobulations, and were either homogeneously hyper-enhancing or heterogeneously isodense at MDCT. None of the tumours had necrosis, haemorrhage, calcification, or loco regional lymphadenopathy on imaging. Sixteen of 25 (64%) patients developed metastatic disease, the most common sites being liver (14/16; 87.5%) and peritoneum (5/16; 31%). Conclusion: Duodenal GISTs are well-circumscribed, round or oval masses, and occur in the second through fourth portions of the duodenum, without lymphadenopathy or duodenal obstruction. Duodenal GISTS metastasize frequently to the liver and peritoneum

  11. Usefulness of 64-slice MDCT for follow-up of young children with coronary artery aneurysm due to Kawasaki disease: initial experience.

    Science.gov (United States)

    Peng, Yun; Zeng, Jinjin; Du, Zhongdong; Sun, Guoqiang; Guo, Huling

    2009-03-01

    To evaluate the initial application and value of 64-slice multidetector computed tomography as an alternative diagnostic modality in the follow-up of young children with coronary artery aneurysm due to Kawasaki disease. Twelve boys (mean age 5.1 years, range 1.8-7.8 years) for follow-up (time range from 1.1 to 5.1 years) of known Kawasaki disease and coronary artery aneurysm underwent 64-slice MDCT ECG-gated coronary angiography. All data were acquired without breath holding. Two pediatric radiologists independently assessed image quality and the diameter of all coronary segments were measured for each patient. The number, position, shape and size of each coronary artery aneurysm were observed and compared with those of ECHO performed previously. A total of 118/156 segments permitted visualization with diagnostic image quality, the CT measurements showed good inter-observer and intra-observer reliability, coefficients were 0.93 and 0.88, respectively. A total of 30 coronary artery aneurysms were identified with measured mean of 7.5+/-3.8 mm in diameter, and of 12.4+/-9.1 mm in longitudinal lengths.10 tumors were small, 8 tumors were medium and 12 tumors were giant aneurysm. The affected segments included LM7/12(58.3%), 9/12(75%) of LAD1, 4/12(33.3%) of LAD2, 2/12(16.7%) of LCX1; 6/12(50%) of RCA1, 9/12(75%) of RCA2 and 4/12(33.3%) of RCA3, including affected two segments in 9 tumors and three segments in 1 tumor. Calcifications were found in 5 aneurysms and 3/5 with thrombosis; six stenotic segments were found. ECHO failed to detect 8 tumors with 2/8 in LAD, 1/8 in LCX and 5/8 in RCA, and those included 4 small aneurysms. The use of 64-slice MDCT angiography proved valuable for monitoring young children with Kawasaki disease. However, further study is necessary to specify the sensitivity and specificity of MDCT in the follow-up.

  12. Usefulness of 64-slice MDCT for follow-up of young children with coronary artery aneurysm due to Kawasaki disease: Initial experience

    International Nuclear Information System (INIS)

    Peng Yun; Zeng Jinjin; Du Zhongdong; Sun Guoqiang; Guo Huling

    2009-01-01

    To evaluate the initial application and value of 64-slice multidetector computed tomography as an alternative diagnostic modality in the follow-up of young children with coronary artery aneurysm due to Kawasaki disease. Twelve boys (mean age 5.1 years, range 1.8-7.8 years) for follow-up (time range from 1.1 to 5.1 years) of known Kawasaki disease and coronary artery aneurysm underwent 64-slice MDCT ECG-gated coronary angiography. All data were acquired without breath holding. Two pediatric radiologists independently assessed image quality and the diameter of all coronary segments were measured for each patient. The number, position, shape and size of each coronary artery aneurysm were observed and compared with those of ECHO performed previously. A total of 118/156 segments permitted visualization with diagnostic image quality, the CT measurements showed good inter-observer and intra-observer reliability, coefficients were 0.93 and 0.88, respectively. A total of 30 coronary artery aneurysms were identified with measured mean of 7.5 ± 3.8 mm in diameter, and of 12.4 ± 9.1 mm in longitudinal lengths.10 tumors were small, 8 tumors were medium and 12 tumors were giant aneurysm. The affected segments included LM7/12(58.3%), 9/12(75%) of LAD1, 4/12(33.3%) of LAD2, 2/12(16.7%) of LCX1; 6/12(50%) of RCA1, 9/12(75%) of RCA2 and 4/12(33.3%) of RCA3, including affected two segments in 9 tumors and three segments in 1 tumor. Calcifications were found in 5 aneurysms and 3/5 with thrombosis; six stenotic segments were found. ECHO failed to detect 8 tumors with 2/8 in LAD, 1/8 in LCX and 5/8 in RCA, and those included 4 small aneurysms. The use of 64-slice MDCT angiography proved valuable for monitoring young children with Kawasaki disease. However, further study is necessary to specify the sensitivity and specificity of MDCT in the follow-up.

  13. Usefulness of 64-slice MDCT for follow-up of young children with coronary artery aneurysm due to Kawasaki disease: Initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Peng Yun [Imaging Center, Beijing Children' s Hospital Affiliated to Capital Medical University, 56, Nanlishi Road, Xicheng District, Beijing 100045 (China)], E-mail: ppengyun@yahoo.com; Zeng Jinjin [Imaging Center, Beijing Children' s Hospital Affiliated to Capital Medical University, 56, Nanlishi Road, Xicheng District, Beijing 100045 (China); Du Zhongdong [Pediatric Cardiovascular Department, Beijing Children' s Hospital Affiliated to Capital Medical University, 56, Nanlishi Road, Xicheng District, Beijing 100045 (China); Sun Guoqiang [Imaging Center, Beijing Children' s Hospital Affiliated to Capital Medical University, 56, Nanlishi Road, Xicheng District, Beijing 100045 (China); Guo Huling [Pediatric Cardiovascular Department, Beijing Children' s Hospital Affiliated to Capital Medical University, 56, Nanlishi Road, Xicheng District, Beijing 100045 (China)

    2009-03-15

    To evaluate the initial application and value of 64-slice multidetector computed tomography as an alternative diagnostic modality in the follow-up of young children with coronary artery aneurysm due to Kawasaki disease. Twelve boys (mean age 5.1 years, range 1.8-7.8 years) for follow-up (time range from 1.1 to 5.1 years) of known Kawasaki disease and coronary artery aneurysm underwent 64-slice MDCT ECG-gated coronary angiography. All data were acquired without breath holding. Two pediatric radiologists independently assessed image quality and the diameter of all coronary segments were measured for each patient. The number, position, shape and size of each coronary artery aneurysm were observed and compared with those of ECHO performed previously. A total of 118/156 segments permitted visualization with diagnostic image quality, the CT measurements showed good inter-observer and intra-observer reliability, coefficients were 0.93 and 0.88, respectively. A total of 30 coronary artery aneurysms were identified with measured mean of 7.5 {+-} 3.8 mm in diameter, and of 12.4 {+-} 9.1 mm in longitudinal lengths.10 tumors were small, 8 tumors were medium and 12 tumors were giant aneurysm. The affected segments included LM7/12(58.3%), 9/12(75%) of LAD1, 4/12(33.3%) of LAD2, 2/12(16.7%) of LCX1; 6/12(50%) of RCA1, 9/12(75%) of RCA2 and 4/12(33.3%) of RCA3, including affected two segments in 9 tumors and three segments in 1 tumor. Calcifications were found in 5 aneurysms and 3/5 with thrombosis; six stenotic segments were found. ECHO failed to detect 8 tumors with 2/8 in LAD, 1/8 in LCX and 5/8 in RCA, and those included 4 small aneurysms. The use of 64-slice MDCT angiography proved valuable for monitoring young children with Kawasaki disease. However, further study is necessary to specify the sensitivity and specificity of MDCT in the follow-up.

  14. Enhancement pattern of small hepatocellular carcinoma (HCC) at contrast-enhanced US (CEUS), MDCT, and MRI: Intermodality agreement and comparison of diagnostic sensitivity between 2005 and 2010 American Association for the Study of Liver Diseases (AASLD) guidelines

    International Nuclear Information System (INIS)

    Furlan, Alessandro; Marin, Daniele; Cabassa, Paolo; Taibbi, Adele; Brunelli, Elena; Agnello, Francesco; Lagalla, Roberto; Brancatelli, Giuseppe

    2012-01-01

    Objective: To evaluate agreement between contrast-enhanced ultrasound (CEUS), multi-detector row computed tomography (MDCT) and magnetic resonance imaging (MRI) for the assessment of typical and atypical enhancement patterns of small hepatocellular carcinoma (HCC); and to compare diagnostic sensitivity of 2005 and 2010 American Association for the Study of Liver Diseases (AASLD) guidelines. Materials and methods: Between January 2008 and December 2009, we included cirrhotic patients with newly diagnosed 10–20 mm HCC imaged at two contrast-enhanced imaging techniques among CEUS, MDCT, and MRI. Dynamic studies were reviewed by two radiologists to assess enhancement pattern. Percentage of cases with concordant findings and Cohen coefficient (k) were calculated. McNemar's test was used to compare sensitivity between 2005 and 2010 AASLD guidelines. Results: There were 91 patients (69 M; 22 F; mean age, 68 years) with 96 HCCs, studied with a combination of CEUS and MDCT (n = 59), CEUS and MRI (n = 26), or MDCT and MRI (n = 11). Intermodality agreement for assessment of tumor enhancement pattern was 67% (k = 0.294, P = 0.001). Typical enhancement pattern was detected coincidentally at two imaging modalities in 50 (52%) HCCs. Sensitivity for the diagnosis of HCC increased significantly using the 2010 AASLD (81/96 (84%) vs. 50/96 (52%), P < 0.001). Conclusions: Agreement between two imaging modalities for the detection of typical tumor enhancement pattern was reached in 52% of cases. The 2010 AASLD guidelines significantly increased the sensitivity for the diagnosis of HCC

  15. Airborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review.

    Science.gov (United States)

    Ai, Z T; Melikov, A K

    2018-07-01

    This article reviews past studies of airborne transmission between occupants in indoor environments, focusing on the spread of expiratory droplet nuclei from mouth/nose to mouth/nose for non-specific diseases. Special attention is paid to summarizing what is known about the influential factors, the inappropriate simplifications of the thermofluid boundary conditions of thermal manikins, the challenges facing the available experimental techniques, and the limitations of available evaluation methods. Secondary issues are highlighted, and some new ways to improve our understanding of airborne transmission indoors are provided. The characteristics of airborne spread of expiratory droplet nuclei between occupants, which are influenced correlatively by both environmental and personal factors, were widely revealed under steady-state conditions. Owing to the different boundary conditions used, some inconsistent findings on specific influential factors have been published. The available instrumentation was too slow to provide accurate concentration profiles for time-dependent evaluations of events with obvious time characteristics, while computational fluid dynamics (CFD) studies were mainly performed in the framework of inherently steady Reynolds-averaged Navier-Stokes modeling. Future research needs in 3 areas are identified: the importance of the direction of indoor airflow patterns, the dynamics of airborne transmission, and the application of CFD simulations. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Iterative reconstruction technique with reduced volume CT dose index: diagnostic accuracy in pediatric acute appendicitis

    International Nuclear Information System (INIS)

    Didier, Ryne A.; Vajtai, Petra L.; Hopkins, Katharine L.

    2015-01-01

    Iterative reconstruction technique has been proposed as a means of reducing patient radiation dose in pediatric CT. Yet, the effect of such reductions on diagnostic accuracy has not been thoroughly evaluated. This study compares accuracy of diagnosing pediatric acute appendicitis using contrast-enhanced abdominopelvic CT scans performed with traditional pediatric weight-based protocols and filtered back projection reconstruction vs. a filtered back projection/iterative reconstruction technique blend with reduced volume CT dose index (CTDI vol ). Results of pediatric contrast-enhanced abdominopelvic CT scans done for pain and/or suspected appendicitis were reviewed in two groups: A, 192 scans performed with the hospital's established weight-based CT protocols and filtered back projection reconstruction; B, 194 scans performed with iterative reconstruction technique and reduced CTDI vol . Reduced CTDI vol was achieved primarily by reductions in effective tube current-time product (mAs eff ) and tube peak kilovoltage (kVp). CT interpretation was correlated with clinical follow-up and/or surgical pathology. CTDI vol , size-specific dose estimates (SSDE) and performance characteristics of the two CT techniques were then compared. Between groups A and B, mean CTDI vol was reduced by 45%, and mean SSDE was reduced by 46%. Sensitivity, specificity and diagnostic accuracy were 96%, 97% and 96% in group A vs. 100%, 99% and 99% in group B. Accuracy in diagnosing pediatric acute appendicitis was maintained in contrast-enhanced abdominopelvic CT scans that incorporated iterative reconstruction technique, despite reductions in mean CTDI vol and SSDE by nearly half as compared to the hospital's traditional weight-based protocols. (orig.)

  17. Reirradiation of Large-Volume Recurrent Glioma With Pulsed Reduced-Dose-Rate Radiotherapy

    International Nuclear Information System (INIS)

    Adkison, Jarrod B.; Tome, Wolfgang; Seo, Songwon; Richards, Gregory M.; Robins, H. Ian; Rassmussen, Karl; Welsh, James S.; Mahler, Peter A.; Howard, Steven P.

    2011-01-01

    Purpose: Pulsed reduced-dose-rate radiotherapy (PRDR) is a reirradiation technique that reduces the effective dose rate and increases the treatment time, allowing sublethal damage repair during irradiation. Patients and Methods: A total of 103 patients with recurrent glioma underwent reirradiation using PRDR (86 considered to have Grade 4 at PRDR). PRDR was delivered using a series of 0.2-Gy pulses at 3-min intervals, creating an apparent dose rate of 0.0667 Gy/min to a median dose of 50 Gy (range, 20-60) delivered in 1.8-2.0-Gy fractions. The mean treatment volume was 403.5 ± 189.4 cm 3 according to T 2 -weighted magnetic resonance imaging and a 2-cm margin. Results: For the initial or upgraded Grade 4 cohort (n = 86), the median interval from the first irradiation to PRDR was 14 months. Patients undergoing PRDR within 14 months of the first irradiation (n = 43) had a median survival of 21 weeks. Those treated ≥14 months after radiotherapy had a median survival of 28 weeks (n = 43; p = 0.004 and HR = 1.82 with a 95% CI ranging from 1.25 to 3.10). These data compared favorably to historical data sets, because only 16% of the patients were treated at first relapse (with 46% treated at the second relapse, 32% at the third or fourth relapse, and 4% at the fourth or fifth relapse). The median survival since diagnosis and retreatment was 6.3 years and 11.4 months for low-grade, 4.1 years and 5.6 months for Grade 3, and 1.6 years and 5.1 months for Grade 4 tumors, respectively, according to the initial histologic findings. Multivariate analysis revealed age at the initial diagnosis, initial low-grade disease, and Karnofsky performance score of ≥80 to be significant predictors of survival after initiation of PRDR. Conclusion: PRDR allowed for safe retreatment of larger volumes to high doses with palliative benefit.

  18. Intraoperative and postoperative evaluation of low tidal volume combined with low-level positive end-expiratory pressure ventilation in laparoscopic surgery in elderly patients

    Directory of Open Access Journals (Sweden)

    Ye-Qiu Li

    2016-01-01

    Full Text Available Objective: To evaluate intraoperative and postoperative condition of low tidal volume combined with low-level positive end-expiratory pressure ventilation in laparoscopic surgery in elderly patients. Methods: A total of 176 cases of elderly patients (more than 60 years old receiving laparoscopic surgery in our hospital from July 2013 to July 2015 were selected as research subjects and randomly divided into observation group and control group, each group included 88 cases, control group received conventional ventilation strategy, observation group received low tidal volume combined with low-level positive end-expiratory pressure ventilation strategy, and then levels of hemodynamic indexes, respiratory mechanical indexes, serology indexes and cerebral vessel related indexes, etc of two groups were compared. Results: Intraoperative and postoperative heart rate and mean arterial pressure levels of observation group were lower than those of control group, arterial partial pressure of oxygen and oxygenation index levels were higher than those of control group and differences had statistical significance (P<0.05; intraoperative APIP and Pplat values of observation group were lower than those of control group, Cs value was higher than that of control group and differences had statistical significance (P<0.05; intraoperative and postoperative serum IL-8 and TNF-α levels of observation group were lower than those of control group, IL-10 level was higher than that of control group and differences had statistical significance (P<0.05; intraoperative and postoperative PjvO2, SjvO2 and CjvO2 levels of observation group were higher than those of control group, Da-jvO2 level was lower than that of control group and differences had statistical significance (P<0.05. Conclusions: When elderly patients receive laparoscopic surgery, the use of low tidal volume combined with low-level positive end-expiratory pressure ventilation strategy can stabilize hemodynamic

  19. Validity of peak expiratory flow measurement in assessing reversibility of airflow obstruction.

    Science.gov (United States)

    Dekker, F W; Schrier, A C; Sterk, P J; Dijkman, J H

    1992-01-01

    BACKGROUND: Assessing the reversibility of airflow obstruction by peak expiratory (PEF) measurements would be practicable in general practice, but its usefulness has not been investigated. METHODS: PEF measurements were performed (miniWright peak flow meter) in 73 general practice patients (aged 40 to 84) with a history of asthma or chronic obstructive lung disease before and after 400 micrograms inhaled sulbutamol. The change in PEF was compared with the change in forced expiratory volume in one second (FEV1). Reversible airflow obstruction was analysed in two ways according to previous criteria. When defined as a 9% or greater increase in FEV1 expressed as a percentage of predicted values reversibility was observed in 42% of patients. Relative operating characteristic analysis showed that an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (the sensitivity and specificity of an increase of 60 l/min in detecting a 9% or more increase in FEV1 as a percentage of predicted values were 68% and 93% respectively, with a positive predictive value of 87%). When defined as an increase of 190 ml or more in FEV1, reversible airflow obstruction was observed in 53% of patients. Again an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (sensitivity 56%, specificity 94%, and positive predictive value 92%). CONCLUSION: Absolute changes in PEF can be used as a simple technique to diagnose reversible airflow obstruction in patients from general practice. PMID:1519192

  20. Current role of MDCT in the diagnosis of coronary artery disease (2011). A clinical guideline of the Austrian Societies of Cardiology and Radiology

    International Nuclear Information System (INIS)

    Hergan, K.; Globits, S.; Loewe, C.

    2011-01-01

    The clinical guideline of the Austrian Societies for Cardiology and Radiology on the actual role of MDCT in the diagnosis of coronary artery diseases includes the following issues: CT calcium scoring; CT angiography (CTA) of the coronaries; actually recommended application of MDCR; generally inappropriate use of the technique for specific patients; radiation exposure; structural and organizational framework.