WorldWideScience

Sample records for recovery 3d flair

  1. 3D-Flair sequence at 3T in cochlear otosclerosis

    International Nuclear Information System (INIS)

    Lombardo, Francesco; De Cori, Sara; Aghakhanyan, Gayane; Montanaro, Domenico; De Marchi, Daniele; Frijia, Francesca; Canapicchi, Raffaello; Fortunato, Susanna; Forli, Francesca; Berrettini, Stefano; Chiappino, Dante

    2016-01-01

    To assess the capability of three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequences in detecting signal alterations of the endolabyrinthine fluid in patients with otosclerosis. 3D-FLAIR before and after (-/+) gadolinium (Gd) administration was added to the standard MR protocol and acquired in 13 patients with a clinical/audiological diagnosis of severe/profound hearing loss in otosclerosis who were candidates for cochlear implantation and in 11 control subjects using 3-T magnetic resonance imaging (MRI) equipment. The MRI signal of the fluid-filled cochlea was assessed both visually and calculating the signal intensity ratio (SIR = signal intensity cochlea/brainstem). We revealed no endocochlear signal abnormalities on T1-weighted -/+ Gd images for either group, while on 3D-FLAIR we found bilateral hyperintensity with enhancement after Gd administration in eight patients and bilateral hyperintensity without enhancement in one patient. No endocochlear signal abnormalities were detected in other patients or the control group. Using 3-T MRI equipment, the 3D-FLAIR -/+ Gd sequence is able to detect the blood-labyrinth barrier (BLB) breakdown responsible for alterations of the endolabyrinthine fluid in patients with cochlear otosclerosis. We believe that 3D-FLAIR +/- Gd is an excellent imaging modality to assess the intra-cochlear damage in otosclerosis patients. (orig.)

  2. 3D-Flair sequence at 3T in cochlear otosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Lombardo, Francesco; De Cori, Sara; Aghakhanyan, Gayane; Montanaro, Domenico; De Marchi, Daniele; Frijia, Francesca; Canapicchi, Raffaello [Fondazione CNR Regione Toscana ' ' G. Monasterio' ' , Neuroradiology Unit, Pisa (Italy); Fortunato, Susanna; Forli, Francesca; Berrettini, Stefano [University of Pisa, ENT Audiology Phoniatry Unit, Department of Neuroscience, Pisa (Italy); Chiappino, Dante [Fondazione CNR Regione Toscana ' ' G. Monasterio' ' , Department of Radiology, Massa (Italy)

    2016-10-15

    To assess the capability of three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequences in detecting signal alterations of the endolabyrinthine fluid in patients with otosclerosis. 3D-FLAIR before and after (-/+) gadolinium (Gd) administration was added to the standard MR protocol and acquired in 13 patients with a clinical/audiological diagnosis of severe/profound hearing loss in otosclerosis who were candidates for cochlear implantation and in 11 control subjects using 3-T magnetic resonance imaging (MRI) equipment. The MRI signal of the fluid-filled cochlea was assessed both visually and calculating the signal intensity ratio (SIR = signal intensity cochlea/brainstem). We revealed no endocochlear signal abnormalities on T1-weighted -/+ Gd images for either group, while on 3D-FLAIR we found bilateral hyperintensity with enhancement after Gd administration in eight patients and bilateral hyperintensity without enhancement in one patient. No endocochlear signal abnormalities were detected in other patients or the control group. Using 3-T MRI equipment, the 3D-FLAIR -/+ Gd sequence is able to detect the blood-labyrinth barrier (BLB) breakdown responsible for alterations of the endolabyrinthine fluid in patients with cochlear otosclerosis. We believe that 3D-FLAIR +/- Gd is an excellent imaging modality to assess the intra-cochlear damage in otosclerosis patients. (orig.)

  3. Comparison of 3D cube FLAIR with 2D FLAIR for multiple sclerosis imaging at 3 tesla

    Energy Technology Data Exchange (ETDEWEB)

    Patzig, M.; Brueckmann, H.; Fesl, G. [Muenchen Univ. (Germany). Dept. of Neuroradiology; Burke, M. [GE Healthcare, Solingen (Germany)

    2014-05-15

    Purpose: Three-dimensional (3 D) MRI sequences allow improved spatial resolution with good signal and contrast properties as well as multiplanar reconstruction. We sought to compare Cube, a 3 D FLAIR sequence, to a standard 2 D FLAIR sequence in multiple sclerosis (MS) imaging. Materials and Methods: Examinations were performed in the clinical routine on a 3.0 Tesla scanner. 12 patients with definite MS were included. Lesions with MS-typical properties on the images of Cube FLAIR and 2 D FLAIR sequences were counted and allocated to different brain regions. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated. Results: With 384 the overall number of lesions found with Cube FLAIR was significantly higher than with 2 D FLAIR (N = 221). The difference was mostly accounted for by supratentorial lesions (N = 372 vs. N = 216) while the infratentorial lesion counts were low in both sequences. SNRs and CNRs were significantly higher in CUBE FLAIR with the exception of the CNR of lesion to gray matter, which was not significantly different. Conclusion: Cube FLAIR showed a higher sensitivity for MS lesions compared to a 2 D FLAIR sequence. 3 D FLAIR might replace 2 D FLAIR sequences in MS imaging in the future. (orig.)

  4. Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results

    International Nuclear Information System (INIS)

    Bink, Andrea; Gaa, Jochen; Lanfermann, Heinrich; Zanella, Friedhelm E.; Schmitt, Melanie; Mugler, John P.

    2006-01-01

    The aim of this study was to compare conventional 2D FLAIR and single-slab 3D FLAIR sequences in the detection of lesions in patients with multiple sclerosis. Eight patients with MS were examined at 3.0 T by using a 2D FLAIR sequence and a single-slab 3D FLAIR sequence. A comparison of lesion detectability was performed for the following regions: periventricular, nonperiventricular/juxtacortical and infratentorial. The contrast-to-noise ratios (CNRs) between lesions and brain tissue and CSF were calculated for each sequence. A total of 424 lesions were found using the 2D FLAIR sequence, while with the 3D FLAIR sequence 719 lesions were found. With the 2D FLAIR sequence, 41% fewer lesions were detected than with the 3D FLAIR sequence. Further, 40% fewer supratentorial and 62.5% fewer infratentorial lesions were found with the 2D FLAIR sequence. In images acquired with the 3D FLAIR sequence, the lesions had significantly higher CNRs than in images acquired with the 2D FLAIR sequence. These are the first results using a single-slab 3D FLAIR sequence at 3.0 T for detection of lesions in patients with MS. With the 3D FLAIR sequence significantly higher CNRs were achieved and significantly more lesions in patients with MS were detected. (orig.)

  5. Signal alteration of the cochlear perilymph on 3 different sequences after intratympanic Gd-DTPA administration at 3 tesla. Comparison of 3D-FLAIR, 3D-T1-weighted imaging, and 3D-CISS

    International Nuclear Information System (INIS)

    Yamazaki, Masahiro; Naganawa, Shinji; Kawai, Hisashi; Nihashi, Takashi; Nakashima, Tsutomu

    2010-01-01

    Three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) imaging after intratympanic gadolinium injection is useful for pathophysiologic and morphologic analysis of the inner ear. However, statistical analysis of differences in inner ear signal intensity among 3D-FLAIR and other sequences has not been reported. We evaluated the signal intensity of cochlear fluid on each of 3D-FLAIR, 3D-T 1 -weighted imaging (T 1 WI), and 3D-constructive interference in the steady state (CISS) to clarify the differences in contrast effect among these 3 sequences using intratympanic gadolinium injection. Twenty-one patients underwent 3D-FLAIR, 3D-T 1 WI, and 3D-CISS imaging at 3 tesla 24 hours after intratympanic injection of gadolinium. We determined regions of interest of the cochleae (C) and medulla oblongata (M) on each image, evaluated the signal intensity ratio between C and M (CM ratio), and determined the ratio of cochlear signal intensity of the injected side to that of the non-injected side (contrast value). The CM ratio of the injected side (3.00±1.31, range, 0.53 to 4.88, on 3D-FLAIR; 0.83±0.30, range, 0.36 to 1.58 on 3D-T 1 WI) was significantly higher than that of the non-injected side (0.52±0.14, range, 0.30 to 0.76 on 3D-FLAIR; 0.49±0.11, range, 0.30 to 0.71 on 3D-T 1 WI) on 3D-FLAIR and 3D-T 1 WI (P 1 WI (1.73±0.60 range, 0.98 to 3.09) (P<0.001). The 3D-FLAIR sequence is the most sensitive for observing alteration in inner ear fluid signal after intratympanic gadolinium injection. Our results warrant use of 3D-FLAIR as a sensitive imaging technique to clarify the pathological and morphological mechanisms of disorders of the inner ear. (author)

  6. Comparison of post-contrast 3D-T1-MPRAGE, 3D-T1-SPACE and 3D-T2-FLAIR MR images in evaluation of meningeal abnormalities at 3-T MRI.

    Science.gov (United States)

    Jeevanandham, Balaji; Kalyanpur, Tejas; Gupta, Prashant; Cherian, Mathew

    2017-06-01

    This study was to assess the usefulness of newer three-dimensional (3D)-T 1 sampling perfection with application optimized contrast using different flip-angle evolutions (SPACE) and 3D-T 2 fluid-attenuated inversion recovery (FLAIR) sequences in evaluation of meningeal abnormalities. 78 patients who presented with high suspicion of meningeal abnormalities were evaluated using post-contrast 3D-T 2 -FLAIR, 3D-T 1 magnetization-prepared rapid gradient-echo (MPRAGE) and 3D-T 1 -SPACE sequences. The images were evaluated independently by two radiologists for cortical gyral, sulcal space, basal cisterns and dural enhancement. The diagnoses were confirmed by further investigations including histopathology. Post-contrast 3D-T 1 -SPACE and 3D-T 2 -FLAIR images yielded significantly more information than MPRAGE images (p evaluation of meningeal abnormalities and when used in combination have the maximum sensitivity for leptomeningeal abnormalities. The negative-predictive value is nearly 100%, where no leptomeningeal abnormality was detected on these sequences. Advances in knowledge: Post-contrast 3D-T 1 -SPACE and 3D-T 2 -FLAIR images are more useful than 3D-T 1 -MPRAGE images in evaluation of meningeal abnormalities.

  7. Patient-specific 3D FLAIR for enhanced visualization of brain white matter lesions in multiple sclerosis.

    Science.gov (United States)

    Gabr, Refaat E; Pednekar, Amol S; Govindarajan, Koushik A; Sun, Xiaojun; Riascos, Roy F; Ramírez, María G; Hasan, Khader M; Lincoln, John A; Nelson, Flavia; Wolinsky, Jerry S; Narayana, Ponnada A

    2017-08-01

    To improve the conspicuity of white matter lesions (WMLs) in multiple sclerosis (MS) using patient-specific optimization of single-slab 3D fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI). Sixteen MS patients were enrolled in a prospective 3.0T MRI study. FLAIR inversion time and echo time were automatically optimized for each patient during the same scan session based on measurements of the relative proton density and relaxation times of the brain tissues. The optimization criterion was to maximize the contrast between gray matter (GM) and white matter (WM), while suppressing cerebrospinal fluid. This criterion also helps increase the contrast between WMLs and WM. The performance of the patient-specific 3D FLAIR protocol relative to the fixed-parameter protocol was assessed both qualitatively and quantitatively. Patient-specific optimization achieved a statistically significant 41% increase in the GM-WM contrast ratio (P < 0.05) and 32% increase in the WML-WM contrast ratio (P < 0.01) compared with fixed-parameter FLAIR. The increase in WML-WM contrast ratio correlated strongly with echo time (P < 10 -11 ). Two experienced neuroradiologists indicated substantially higher lesion conspicuity on the patient-specific FLAIR images over conventional FLAIR in 3-4 cases (intrarater correlation coefficient ICC = 0.72). In no case was the image quality of patient-specific FLAIR considered inferior to conventional FLAIR by any of the raters (ICC = 0.32). Changes in proton density and relaxation times render fixed-parameter FLAIR suboptimal in terms of lesion contrast. Patient-specific optimization of 3D FLAIR increases lesion conspicuity without scan time penalty, and has potential to enhance the detection of subtle and small lesions in MS. 1 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:557-564. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Endolympathic hydrops in patients with vestibular schwannoma: visualization by non-contrast-enhanced 3D FLAIR

    Energy Technology Data Exchange (ETDEWEB)

    Naganawa, Shinji; Kawai, Hisashi [Nagoya University Graduate School of Medicine, Department of Radiology, Nagoya (Japan); Sone, Michihiko; Nakashima, Tsutomu [Nagoya University Graduate School of Medicine, Department of Otorhinolaryngology, Nagoya (Japan); Ikeda, Mitsuru [Nagoya University School of Health Sciences, Department of Radiological Technology, Nagoya (Japan)

    2011-12-15

    Signal intensity of ipsilateral labyrinthine lymph fluid has been reported to increase in most cases with vestibular schwannoma (VS) on 3D fluid attenuated inversion recovery (FLAIR). The purpose of this study was twofold, (1) to evaluate if endolymphatic space can be recognized in the patients with VS on non-contrast-enhanced 3D-FLAIR images and (2) to know if the vertigo in the patients with VS correlates to vestibular endolymphatic hydrops. From the introduction of 32-channel head coil at 3 T in May 2008 to June 2010, 15 cases with unilateral VS were identified in the radiology report database. The two cases without a significant signal increase on 3D FLAIR were excluded. Resting 13 cases were retrospectively analyzed in regard to the recognition of endolymphatic hydrops in the cochlea and vestibule and to the correlation between the patients' symptoms and endolymphatic hydrops. In all cases, vestibular endolymphatic space can be recognized on non-contrast-enhanced 3D FLAIR. Cochlear endolymphatic space can be identified only in one case with significant hydrops. Vestibular hydrops was identified in four cases. Among these four cases, three had vertigo, and one had no vertigo. In those nine cases without hydrops, two had vertigo, and seven did not have vertigo. No significant correlation between vertigo and vestibular hydrops was found. Vestibular endolymphatic space can be recognized on non-contrast-enhanced 3D FLAIR. In some patients with VS, vestibular hydrops is seen; however, endolymphatic hydrops in the vestibule might not be the only responsible cause of vertigo in the patients with VS. (orig.)

  9. Endolympathic hydrops in patients with vestibular schwannoma: visualization by non-contrast-enhanced 3D FLAIR

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Kawai, Hisashi; Sone, Michihiko; Nakashima, Tsutomu; Ikeda, Mitsuru

    2011-01-01

    Signal intensity of ipsilateral labyrinthine lymph fluid has been reported to increase in most cases with vestibular schwannoma (VS) on 3D fluid attenuated inversion recovery (FLAIR). The purpose of this study was twofold, (1) to evaluate if endolymphatic space can be recognized in the patients with VS on non-contrast-enhanced 3D-FLAIR images and (2) to know if the vertigo in the patients with VS correlates to vestibular endolymphatic hydrops. From the introduction of 32-channel head coil at 3 T in May 2008 to June 2010, 15 cases with unilateral VS were identified in the radiology report database. The two cases without a significant signal increase on 3D FLAIR were excluded. Resting 13 cases were retrospectively analyzed in regard to the recognition of endolymphatic hydrops in the cochlea and vestibule and to the correlation between the patients' symptoms and endolymphatic hydrops. In all cases, vestibular endolymphatic space can be recognized on non-contrast-enhanced 3D FLAIR. Cochlear endolymphatic space can be identified only in one case with significant hydrops. Vestibular hydrops was identified in four cases. Among these four cases, three had vertigo, and one had no vertigo. In those nine cases without hydrops, two had vertigo, and seven did not have vertigo. No significant correlation between vertigo and vestibular hydrops was found. Vestibular endolymphatic space can be recognized on non-contrast-enhanced 3D FLAIR. In some patients with VS, vestibular hydrops is seen; however, endolymphatic hydrops in the vestibule might not be the only responsible cause of vertigo in the patients with VS. (orig.)

  10. Fast fluid-attenuated inversion-recovery imaging: first experience with a 3D version in epilepsy

    International Nuclear Information System (INIS)

    Wieshmann, U.C.; Symms, M.R.; Bartlett, P.A.; Shorvon, S.D.; Barker, G.J.; Stevens, J.M.

    1998-01-01

    We developed a 3D version of fast fluid-attenuated inversion-recovery imaging (FLAIR) which provides images with a slice thickness of 1.5 mm. We present our initial experience with 3D fast FLAIR in patients with epilepsy. We compared 3D fast FLAIR (slice thickness 1.5 mm), 2D fast FLAIR (slice thickness 5 mm) and a 3D spoiled GRASS (IRSPGR) sequence (slice thickness 1.5 mm) in 10 patients with lesional epilepsy (head injury 1, hippocampal sclerosis 2, low-grade glioma 2, dysembryoplastic neuroepithelial tumour 2, polymicrogyria 1, perinatal infarct 1 and presumed thrombosed aneurysm 1). Both 2D and 3D fast FLAIR sequences yielded higher conspicuity for lesions than the T1-weighted IRSPGR sequence, except in the patient with polymicrogyria. The extent of the lesion, in particular that of low-grade tumours, was best assessed on 3D fast FLAIR images. 3D fast FLAIR may be a useful additional tool especially for imaging low-grade tumours. (orig.)

  11. Increased signal intensity of the cochlea on pre- and post-contrast enhanced 3D-FLAIR in patients with vestibular schwannoma

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Masahiro; Naganawa, Shinji; Kawai, Hisashi; Nihashi, Takashi [Nagoya University, Department of Radiology, Graduate School of Medicine, Nagoya (Japan); Fukatsu, Hiroshi [Aichi Medical University Hospital, Department of Medical Informatics, Nagakute (Japan); Nakashima, Tsutomu [Nagoya University, Department of Otorhinolaryngology, Graduate School of Medicine, Nagoya (Japan)

    2009-12-15

    In the vestibular schwannoma patients, the pathophysiologic mechanism of inner ear involvement is still unclear. We investigated the status of the cochleae in patients with vestibular schwannoma by evaluating the signal intensity of cochlear fluid on pre- and post-contrast enhanced thin section three-dimensional fluid-attenuated inversion recovery (3D-FLAIR). Twenty-eight patients were retrospectively analyzed. Post-contrast images were obtained in 18 patients, and 20 patients had the records of their pure-tone audiometry. Regions of interest of both cochleae (C) and of the medulla oblongata (M) were determined on 3D-FLAIR images by referring to 3D heavily T2-weighted images on a workstation. The signal intensity ratio between C and M on the 3D-FLAIR images (CM ratio) was then evaluated. In addition, correlation between the CM ratio and the hearing level was also evaluated. The CM ratio of the affected side was significantly higher than that of the unaffected side (p < 0.001). In the affected side, post-contrast signal elevation was observed (p < 0.005). In 13 patients (26 cochleae) who underwent both gadolinium injection and the pure-tone audiometry, the post-contrast CM ratio correlated with hearing level (p < 0.05). The results of the present study suggest that alteration of cochlear fluid composition and increased permeability of the blood-labyrinthine barrier exist in the affected side in patients with vestibular schwannoma. Furthermore, although weak, positive correlation between post-contrast cochlear signal intensity on 3D-FLAIR and hearing level warrants further study to clarify the relationship between 3D-FLAIR findings and prognosis of hearing preservation surgery. (orig.)

  12. Increased signal intensity of the cochlea on pre- and post-contrast enhanced 3D-FLAIR in patients with vestibular schwannoma

    International Nuclear Information System (INIS)

    Yamazaki, Masahiro; Naganawa, Shinji; Kawai, Hisashi; Nihashi, Takashi; Fukatsu, Hiroshi; Nakashima, Tsutomu

    2009-01-01

    In the vestibular schwannoma patients, the pathophysiologic mechanism of inner ear involvement is still unclear. We investigated the status of the cochleae in patients with vestibular schwannoma by evaluating the signal intensity of cochlear fluid on pre- and post-contrast enhanced thin section three-dimensional fluid-attenuated inversion recovery (3D-FLAIR). Twenty-eight patients were retrospectively analyzed. Post-contrast images were obtained in 18 patients, and 20 patients had the records of their pure-tone audiometry. Regions of interest of both cochleae (C) and of the medulla oblongata (M) were determined on 3D-FLAIR images by referring to 3D heavily T2-weighted images on a workstation. The signal intensity ratio between C and M on the 3D-FLAIR images (CM ratio) was then evaluated. In addition, correlation between the CM ratio and the hearing level was also evaluated. The CM ratio of the affected side was significantly higher than that of the unaffected side (p < 0.001). In the affected side, post-contrast signal elevation was observed (p < 0.005). In 13 patients (26 cochleae) who underwent both gadolinium injection and the pure-tone audiometry, the post-contrast CM ratio correlated with hearing level (p < 0.05). The results of the present study suggest that alteration of cochlear fluid composition and increased permeability of the blood-labyrinthine barrier exist in the affected side in patients with vestibular schwannoma. Furthermore, although weak, positive correlation between post-contrast cochlear signal intensity on 3D-FLAIR and hearing level warrants further study to clarify the relationship between 3D-FLAIR findings and prognosis of hearing preservation surgery. (orig.)

  13. Arterial hyperintensity on BLADE fluid-attenuated inversion recovery images (FLAIR) in hyperacute territorial infarction: comparison with conventional FLAIR

    Energy Technology Data Exchange (ETDEWEB)

    Kwag, Eujean; Lim, Soo Mee; Park, Ji Eun; Chae, In Hye [Ewha Womans University School of Medicine, Department of Radiology, Mokdong Hospital, Seoul (Korea, Republic of)

    2014-09-15

    To evaluate the utility of BLADE fluid-attenuated inversion recovery images (FLAIR) magnetic resonance (MR) imaging compared to conventional FLAIR for the detection of arterial hyperintensity (AH) in hyperacute territorial infarction. We retrospectively analysed MR images of patients with hyperacute (<6 h) territorial infarction over a 9-month study period. Special attention was paid to the presence or absence of AH in the frontal, parietal and temporal lobes and the number of AHs in the sylvian fissure. We also evaluated the presence of three kinds of artefacts on BLADE FLAIR and conventional FLAIR images. AH was seen in 41 (91 %) patients with conventional FLAIR and 45 (100 %) patients with BLADE FLAIR images. More instances of AH were detected in the frontal, parietal and temporal lobes and within the sylvian fissure using BLADE FLAIR. Motion artefacts, pulsation artefacts from the sigmoid sinus and incomplete cerebrospinal fluid (CSF) nulling that reduced image quality were observed more frequently on conventional FLAIR images than on BLADE FLAIR images. BLADE FLAIR sequences are more sensitive than conventional FLAIR for the detection of AH in hyperacute territorial infarctions and provide better image quality by reducing artefacts. They may be used in place of conventional FLAIR for patients with hyperacute stroke. (orig.)

  14. Role of three-dimensional fluid-attenuated inversion recovery (3D FLAIR) and proton density magnetic resonance imaging for the detection and evaluation of lesion extent of focal cortical dysplasia in patients with refractory epilepsy

    International Nuclear Information System (INIS)

    Saini, Jitender; Kesavadas, Chandrasekharan; Thomas, Bejoy; Singh, Atampreet; Rathore, Chathurbhuj; Radhakrishnan, Ashalatha; Radhakrishnan, Kurupath; Bahuleyan, Biji

    2010-01-01

    Background: Focal cortical dysplasia (FCD) is often associated with epilepsy. Identification of FCD can be difficult due to subtle magnetic resonance imaging (MRI) changes. Though fluid-attenuated inversion recovery (FLAIR) sequence detects the majority of these lesions, smaller lesions may go unnoticed while larger lesions may be poorly delineated. Purpose: To determine the ability of a specialized epilepsy protocol in visualizing and delineating the extent of FCD. Material and Methods: We compared the imaging findings in nine patients with cortical malformation who underwent routine epilepsy MR imaging as well as a specialized epilepsy protocol. All imaging was done on a 1.5T MR unit. The specialized epilepsy protocol included 3D FLAIR in the sagittal plane as well as proton density (PD) and high-resolution T2-weighted (T2W) images in the transverse plane. Results: In all nine patients, the specialized protocol identified lesion anatomy better. In three patients in whom routine MRI was normal, the specialized epilepsy protocol including 3D FLAIR helped in identifying the lesions. One of these patients underwent surgery, and histo-pathology revealed a cortical dysplasia. In one patient, lesion characterization was improved, while in the remaining patients the extent of the FCD was more clearly demonstrated in the 3D FLAIR and PD images. Statistical analysis of images for cortical thickness, cortical signal intensity, adjacent white matter abnormalities, and gray-white matter junction showed significant statistical difference in the ability of 3D FLAIR to assess these aspects over conventional images. PD images were also found superior to the routine epilepsy protocol in assessment of cortical signal, adjacent white matter, and gray-white matter junction. Conclusion: Specialized MRI sequences and techniques should be performed whenever there is a high suspicion of cortical dysplasia, especially when they remain occult on conventional MR protocols. These techniques

  15. Evaluation of prospective motion correction of high-resolution 3D-T2-FLAIR acquisitions in epilepsy patients.

    Science.gov (United States)

    Vos, Sjoerd B; Micallef, Caroline; Barkhof, Frederik; Hill, Andrea; Winston, Gavin P; Ourselin, Sebastien; Duncan, John S

    2018-03-02

    T2-FLAIR is the single most sensitive MRI contrast to detect lesions underlying focal epilepsies but 3D sequences used to obtain isotropic high-resolution images are susceptible to motion artefacts. Prospective motion correction (PMC) - demonstrated to improve 3D-T1 image quality in a pediatric population - was applied to high-resolution 3D-T2-FLAIR scans in adult epilepsy patients to evaluate its clinical benefit. Coronal 3D-T2-FLAIR scans were acquired with a 1mm isotropic resolution on a 3T MRI scanner. Two expert neuroradiologists reviewed 40 scans without PMC and 40 with navigator-based PMC. Visual assessment addressed six criteria of image quality (resolution, SNR, WM-GM contrast, intensity homogeneity, lesion conspicuity, diagnostic confidence) on a seven-point Likert scale (from non-diagnostic to outstanding). SNR was also objectively quantified within the white matter. PMC scans had near-identical scores on the criteria of image quality to non-PMC scans, with the notable exception that intensity homogeneity was generally worse. Using PMC, the percentage of scans with bad image quality was substantially lower than without PMC (3.25% vs. 12.5%) on the other five criteria. Quantitative SNR estimates revealed that PMC and non-PMC had no significant difference in SNR (P=0.07). Application of prospective motion correction to 3D-T2-FLAIR sequences decreased the percentage of low-quality scans, reducing the number of scans that need to be repeated to obtain clinically useful data. Copyright © 2018 The Authors. Published by Elsevier Masson SAS.. All rights reserved.

  16. Improved differentiation between MS and vascular brain lesions using FLAIR* at 7 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Kilsdonk, Iris D.; Wattjes, Mike P.; Lopez-Soriano, Alexandra; Jong, Marcus C. de; Graaf, Wolter L. de; Conijn, Mandy M.A.; Barkhof, Frederik [VU University Medical Center, Department of Radiology, De Boelelaan 1118, HZ, Amsterdam (Netherlands); Kuijer, Joost P.A. [VU University Medical Center, Department of Physics and Medical Technology, Amsterdam (Netherlands); Polman, Chris H. [VU University Medical Center, Department of Neurology, Amsterdam (Netherlands); Luijten, Peter R. [University Medical Center, Department of Radiology, Utrecht (Netherlands); Geurts, Jeroen J.G. [VU University, Department of Anatomy and Neurosciences, Amsterdam (Netherlands); Geerlings, Mirjam I. [University Medical Center, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands)

    2014-04-15

    To investigate whether a new magnetic resonance image (MRI) technique called T2*-weighted fluid attenuation inversion recovery (FLAIR*) can differentiate between multiple sclerosis (MS) and vascular brain lesions, at 7 Tesla (T). We examined 16 MS patients and 16 age-matched patients with (risk factors for) vascular disease. 3D-FLAIR and T2*-weighted images were combined into FLAIR* images. Lesion type and intensity, perivascular orientation and presence of a hypointense rim were analysed. In total, 433 cerebral lesions were detected in MS patients versus 86 lesions in vascular patients. Lesions in MS patients were significantly more often orientated in a perivascular manner: 74 % vs. 47 % (P < 0.001). Ten MS lesions (2.3 %) were surrounded by a hypointense rim on FLAIR*, and 24 MS lesions (5.5 %) were hypointense on T2*. No lesions in vascular patients showed any rim or hypointensity. Specificity of differentiating MS from vascular lesions on 7-T FLAIR* increased when the presence of a central vessel was taken into account (from 63 % to 88 %), most obviously for deep white matter lesions (from 69 % to 94 %). High sensitivity remained (81 %). 7-T FLAIR* improves differentiation between MS and vascular lesions based on lesion location, perivascular orientation and presence of hypointense (rims around) lesions. circle A new MRI technique T2*-weighted fluid attenuation inversion recovery (FLAIR*) was investigated. circle FLAIR* at 7-T MRI combines FLAIR and T2* images into a single image. circle FLAIR* at 7 T does not require enhancement with contrast agents. (orig.)

  17. Separate visualization of endolymphatic space, perilymphatic space and bone by a single pulse sequence; 3D-inversion recovery imaging utilizing real reconstruction after intratympanic Gd-DTPA administration at 3 tesla

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Satake, Hiroko; Kawamura, Minako; Fukatsu, Hiroshi; Sone, Michihiko; Nakashima, Tsutomu

    2008-01-01

    Twenty-four hours after intratympanic administration of gadolinium contrast material (Gd), the Gd was distributed mainly in the perilymphatic space. Three-dimensional FLAIR can differentiate endolymphatic space from perilymphatic space, but not from surrounding bone. The purpose of this study was to evaluate whether 3D inversion-recovery turbo spin echo (3D-IR TSE) with real reconstruction could separate the signals of perilymphatic space (positive value), endolymphatic space (negative value) and bone (near zero) by setting the inversion time between the null point of Gd-containing perilymph fluid and that of the endolymph fluid without Gd. Thirteen patients with clinically suspected endolymphatic hydrops underwent intratympanic Gd injection and were scanned at 3 T. A 3D FLAIR and 3D-IR TSE with real reconstruction were obtained. In all patients, low signal of endolymphatic space in the labyrinth on 3D FLAIR was observed in the anatomically appropriate position, and it showed negative signal on 3D-IR TSE. The low signal area of surrounding bone on 3D FLAIR showed near zero signal on 3D-IR TSE. Gd-containing perilymphatic space showed high signal on 3D-IR TSE. In conclusion, by optimizing the inversion time, endolymphatic space, perilymphatic space and surrounding bone can be separately visualized on a single image using a 3D-IR TSE with real reconstruction. (orig.)

  18. Postmortem verification of MS cortical lesion detection with 3D DIR

    NARCIS (Netherlands)

    Seewann, A.M.; Kooi, E.J.; Roosendaal, S.D.; Pouwels, P.J.W.; Wattjes, M.P.; van der Valk, P.; Barkhof, F.; Polman, C.H.; Geurts, J.J.G.

    2012-01-01

    Objective: To assess the sensitivity and specificity of 3D double inversion recovery (DIR) MRI for detecting multiple sclerosis (MS) cortical lesions (CLs) using a direct postmortem MRI to histopathology comparison. Methods: Single-slab 3D DIR and 3D fluid-attenuated inversion recovery (FLAIR)

  19. Efficacy of the fluid attenuated inversion recovery (FLAIR) sequence of MRI as a preoperative diagnosis of hippocampal sclerosis

    International Nuclear Information System (INIS)

    Morioka, Takato; Nishio, Shunji; Mihara, Futoshi; Muraishi, Mitsuteru; Hisada, Kei; Hasuo, Kanehiro; Fukui, Masashi

    1998-01-01

    A newly advanced MRI pulse sequence, the FLAIR (fluid attenuated inversion recovery) imaging, in which a long TE spin echo sequence is used with suppression of the CSF with an inversion pulse, displays the CSF space as a no-signal intensity area. There have been only a few reports on the FLAIR pulse sequence of temporal lobe epilepsy (TLE) as yet. We examined 9 cases of intractable TLE by FLAIR images and analyzed the advantages and disadvantages of the FLAIR pulse sequence for decision making on temporal lobectomy. All patients underwent anterior temporal lobectomy with hippocampectomy, and the diagnoses were confirmed histologically after surgery. Abnormally high T2 signals (HT2S) were more conspicuous with the FLAIR sequence than with any of the conventional sequences. Tilted axial plane, orientated along to the long axis of the hippocampal body, clearly demonstrated hippocampal atrophy (HA). Selection of a FLAIR sequence into the routine MR examination of patients with TLE is recommended. (author)

  20. Clinical usefulness of fluid-attenuated inversion recovery (FLAIR) sequences in intracranial lesions focusing on emergent cases

    Energy Technology Data Exchange (ETDEWEB)

    Kuramochi, Masashi; Niitsu, Mamoru; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Wada, Mitsuyoshi

    1997-06-01

    Fluid-Attenuated Inversion Recovery (FLAIR) Pulse Sequences with inversion times of 1700 ms and echo times of 110 ms were used to demonstrate the brain of cerebrovascular disease (CVD) and brain trauma. The long inversion times and long echo times nulls the signal from cerebrospinal fluid and produces heavy T{sub 2} weighting images. We compared FLAIR Pulse Sequences with T{sub 2} weighted image Pulse Sequences for signal intensities of CVD and trauma. FLAIR Pulse Sequences is useful to detect at the periphery of the cerebral hemispheres, but infratentorial small infarctions often cannot be detected for its iso-intensity and slight intensity changes. In all patient of traumatic-subarachnoid hemorrhage (t-SAH) can be definitely detected high signal intensity of the cerebral hemispheres. (author)

  1. Anterior temporal lobe white matter abnormal signal (ATLAS) as an indicator of seizure focus laterality in temporal lobe epilepsy: comparison of double inversion recovery, FLAIR and T2W MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, Emiko; Kanagaki, Mitsunori; Okada, Tomohisa; Yamamoto, Akira; Togashi, Kaori [Kyoto University Graduate School of Medicine, Department of Diagnostic Imaging and Nuclear Medicine, Kyoto (Japan); Mori, Nobuyuki [Tenri Hospital, Department of Radiology, Tenri, Nara (Japan); Matsumoto, Riki; Ikeda, Akio; Takahashi, Ryosuke [Kyoto University Graduate School of Medicine, Department of Neurology, Kyoto (Japan); Mikuni, Nobuhiro [Sapporo Medical University, Department of Neurosurgery, Sapporo, Hokkaido (Japan); Kunieda, Takeharu; Miyamoto, Susumu [Kyoto University Graduate School of Medicine, Department of Neurosurgery, Kyoto (Japan); Paul, Dominik [Siemens AG Healthcare Sector, Erlangen (Germany)

    2013-01-15

    To investigate the diagnostic capability of anterior temporal lobe white matter abnormal signal (ATLAS) for determining seizure focus laterality in temporal lobe epilepsy (TLE) by comparing different MR sequences. This prospective study was approved by the institutional review board and written informed consent was obtained. Three 3D sequences (double inversion recovery (DIR), fluid-attenuated inversion recovery (FLAIR) and T2-weighted imaging (T2WI)) and two 2D sequences (FLAIR and T2WI) were acquired at 3 T. Signal changes in the anterior temporal white matter of 21 normal volunteers were evaluated. ATLAS laterality was evaluated in 21 TLE patients. Agreement of independent evaluations by two neuroradiologists was assessed using {kappa} statistics. Differences in concordance between ATLAS laterality and clinically defined seizure focus laterality were analysed using McNemar's test with multiple comparisons. Pre-amygdala high signals (PAHS) were detected in all volunteers only on 3D-DIR. Inter-evaluator agreement was moderate to almost perfect for each sequence. Correct diagnosis of seizure laterality was significantly more frequent on 3D-DIR than on any other sequences (P {<=} 0.031 for each evaluator). The most sensitive sequence for detecting ATLAS laterality was 3D-DIR. ATLAS laterality on 3D-DIR can be a good indicator for determining seizure focus localization in TLE. (orig.)

  2. Anterior temporal lobe white matter abnormal signal (ATLAS) as an indicator of seizure focus laterality in temporal lobe epilepsy: comparison of double inversion recovery, FLAIR and T2W MR imaging

    International Nuclear Information System (INIS)

    Morimoto, Emiko; Kanagaki, Mitsunori; Okada, Tomohisa; Yamamoto, Akira; Togashi, Kaori; Mori, Nobuyuki; Matsumoto, Riki; Ikeda, Akio; Takahashi, Ryosuke; Mikuni, Nobuhiro; Kunieda, Takeharu; Miyamoto, Susumu; Paul, Dominik

    2013-01-01

    To investigate the diagnostic capability of anterior temporal lobe white matter abnormal signal (ATLAS) for determining seizure focus laterality in temporal lobe epilepsy (TLE) by comparing different MR sequences. This prospective study was approved by the institutional review board and written informed consent was obtained. Three 3D sequences (double inversion recovery (DIR), fluid-attenuated inversion recovery (FLAIR) and T2-weighted imaging (T2WI)) and two 2D sequences (FLAIR and T2WI) were acquired at 3 T. Signal changes in the anterior temporal white matter of 21 normal volunteers were evaluated. ATLAS laterality was evaluated in 21 TLE patients. Agreement of independent evaluations by two neuroradiologists was assessed using κ statistics. Differences in concordance between ATLAS laterality and clinically defined seizure focus laterality were analysed using McNemar's test with multiple comparisons. Pre-amygdala high signals (PAHS) were detected in all volunteers only on 3D-DIR. Inter-evaluator agreement was moderate to almost perfect for each sequence. Correct diagnosis of seizure laterality was significantly more frequent on 3D-DIR than on any other sequences (P ≤ 0.031 for each evaluator). The most sensitive sequence for detecting ATLAS laterality was 3D-DIR. ATLAS laterality on 3D-DIR can be a good indicator for determining seizure focus localization in TLE. (orig.)

  3. FLAIR images of subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Mikami, Takeshi; Saito, Koji; Okuyama, Tohru; Sakamoto, Yasuo; Takahashi, Akira; Shibata, Kazunori [Kushiro Neurosurgical Hospital, Hokkaido (Japan)

    1996-12-01

    We studied MR fluid attenuated inversion recovery (FLAIR) pulse sequences in 37 cases with subarachnoid hemorrhage caused by aneurysmal rupture. FLAIR sequence suppressed the CSF signal and produced very heavy T{sub 2} weighted images. Subarachnoid hemorrhage was able to be demonstrated as high signal intensity on FLAIR sequences in all patients clear visualization of acute subarachnoid hemorrhage was able to be obtained by MR FLAIR sequences in not only Fisher`s group 3 or 4, but also Fisher`s group 2. Moreover it was suited for the detection of intraaxial hematoma, Sylvian hematoma, subdural hematoma and subarachnoid hemorrhage in the posterior fossa and interhemispheric fissure. Especially, it was useful for detecting intraventricular hemorrhage. Therefore, if patients suffering from subarachnoid hemorrhage present slight headache or atypical symptoms, sometimes it may be more suitable to perform MRI FLAIR pulse sequences first. Aneurysms were found in 21 cases (56.8%). When the aneurysmal size is more than 7 mm, the rate of detection becomes 100%. Aneurysms present various MR appearances because of flow characteristics. Aneurysms were demonstrated as low signal intensity except in 3 cases. In one out of 3 cases, aneurysms were revealed as high signal intensity and in the other two cases, it was revealed as mixed signal intensity. According to the previous studies, rapid flow was demonstrated as low signal intensity by vascular flow void, and delayed flow was demonstrated as high or mixed signal intensity by flow related enhancement and even echo rephasing. MR clearly delineates the size, the lumen, the flow, and the extraaxial location of aneurysms. (K.H.)

  4. A case of Marchiafava-Bignami disease: MRI findings on spin-echo and fluid attenuated inversion recovery (FLAIR) images

    International Nuclear Information System (INIS)

    Yamamoto, Takashi; Ashikaga, Ryuichiro; Araki, Yutaka; Nishimura, Yasumasa

    2000-01-01

    Marchiafava-Bignami disease (MBD) was diagnosed in a 56-year-old man. Spin-echo (SE) magnetic resonance imaging (MRI) at the acute phase showed normal signal areas in the central layer of the corpus callosum (CC), although the intensity of these areas revealed abnormal hyperintensity on fluid attenuated inversion recovery (FLAIR). On follow-up SE MRI at the late phase, the central layer of the CC showed fluid-like intensity. On FLAIR MRI, the lesions of the CC turned into hypointense cores surrounded by hyperintense rims indicating central necrosis and peripheral demyelination. Degenerative changes of the CC in MBD were clearly demonstrated by FLAIR MRI

  5. Multi-contrast, isotropic, single-slab 3D MR imaging in multiple sclerosis

    NARCIS (Netherlands)

    Moraal, Bastiaan; Roosendaal, Stefan; Pouwels, Petra; Vrenken, Hugo; Schijndel, van Ronald; Meier, Dominik; Guttmann, Charles; Geurts, Jeroen; Barkhof, Frederik

    2008-01-01

    To describe signal and contrast properties of an isotropic, single-slab 3D dataset [double inversion- recovery (DIR), fluid-attenuated inversion recovery (FLAIR), T2, and T1-weighted magnetization prepared rapid acquisition gradient-echo (MPRAGE)] and to evaluate its performance in detecting

  6. Evaluation of multimodal segmentation based on 3D T1-, T2- and FLAIR-weighted images - the difficulty of choosing.

    Science.gov (United States)

    Lindig, Tobias; Kotikalapudi, Raviteja; Schweikardt, Daniel; Martin, Pascal; Bender, Friedemann; Klose, Uwe; Ernemann, Ulrike; Focke, Niels K; Bender, Benjamin

    2018-04-15

    Voxel-based morphometry is still mainly based on T1-weighted MRI scans. Misclassification of vessels and dura mater as gray matter has been previously reported. Goal of the present work was to evaluate the effect of multimodal segmentation methods available in SPM12, and their influence on identification of age related atrophy and lesion detection in epilepsy patients. 3D T1-, T2- and FLAIR-images of 77 healthy adults (mean age 35.8 years, 19-66 years, 45 females), 7 patients with malformation of cortical development (MCD) (mean age 28.1 years,19-40 years, 3 females), and 5 patients with left hippocampal sclerosis (LHS) (mean age 49.0 years, 25-67 years, 3 females) from a 3T scanner were evaluated. Segmentation based on T1-only, T1+T2, T1+FLAIR, T2+FLAIR, and T1+T2+FLAIR were compared in the healthy subjects. Clinical VBM results based on the different segmentation approaches for MCD and for LHS were compared. T1-only segmentation overestimated total intracranial volume by about 80ml compared to the other segmentation methods. This was due to misclassification of dura mater and vessels as GM and CSF. Significant differences were found for several anatomical regions: the occipital lobe, the basal ganglia/thalamus, the pre- and postcentral gyrus, the cerebellum, and the brainstem. None of the segmentation methods yielded completely satisfying results for the basal ganglia/thalamus and the brainstem. The best correlation with age could be found for the multimodal T1+T2+FLAIR segmentation. Highest T-scores for identification of LHS were found for T1+T2 segmentation, while highest T-scores for MCD were dependent on lesion and anatomical location. Multimodal segmentation is superior to T1-only segmentation and reduces the misclassification of dura mater and vessels as GM and CSF. Depending on the anatomical region and the pathology of interest (atrophy, lesion detection, etc.), different combinations of T1, T2 and FLAIR yield optimal results. Copyright © 2017 Elsevier

  7. Multi-contrast, isotropic, single-slab 3D MR imaging in multiple sclerosis

    NARCIS (Netherlands)

    Moraal, B.; Roosendaal, S.D.; Pouwels, P.J.W.; Vrenken, H.; van Schijndel, R.A.; Meier, D.S.; Guttmann, C.R.G.; Geurts, J.J.G.; Barkhof, F.

    2008-01-01

    To describe signal and contrast properties of an isotropic, single-slab 3D dataset [double inversion-recovery (DIR), fluid-attenuated inversion recovery (FLAIR), T2, and T1-weighted magnetization prepared rapid acquisition gradient-echo (MPRAGE)] and to evaluate its performance in detecting multiple

  8. Fast FLAIR MR images of intracranial hemorrhage

    International Nuclear Information System (INIS)

    Chun, Eun Ju; Choi, Hye Young; Cho, Young A; Kim, Wha Young

    1998-01-01

    The purpose of this study is to evaluate the signal characteristics of intracranial hemorrhage, as seen on fluid attenuated inversion recovery (FLAIR) MR imaging according to various stages, and to compare FLAIR imaging with spin-echo T1- and T2-weighted MR imaging. We retrospectively evaluated fast FLAIR images along with spin-echo T1- and T2 weighted MR images of 32 lesions in 25 patients (12 males and 14 females, aged 3 - 84 yrs) with intracranial hemorrhagic lesions. For imaging, 1.5 T unit was used, and the nature of the lesions was found to be as follows : intracranial hemorrhage (n=15); tumor (n=9); infarction (n=4); arteriovenous malformation (n=3); and arachnoid cyst with hemorrhage (n=1). On the basis of spin-echo MR imaging, lesions were classified as acute, early subacute, late subacute, early chronic, or late chronic stage. The signal characteristics of intracranial hemorrhage were analysed in accordance with each staging, as seen on MR FLAIR imaging, and compared to the staging seen on spin-echo T1- and T-2 weighted MR imaging. The signal intensity of intracranial hemorrhage, as seen on FLAIR imaging, was not characteristic; it was similar to that of T2WI during the acute and subacute stages, and similiar to that of T1WI during the chronic stage. When used together with spin-echo T1- and T2-weighted MR imaging, however, FLAIR imaging may be useful for the classification of chronic intracranial hemorrhage as either early or late stage. (author). 20 refs., 2 tabs., 6 figs

  9. Can a 15-sec FLAIR replace conventional FLAIR sequence in stroke MR protocols?

    Science.gov (United States)

    Benzakoun, J; Maïer, B; Calvet, D; Edjlali, M; Turc, G; Lion, S; Legrand, L; Ben Hassen, W; Naggara, O; Meder, J F; Mas, J L; Oppenheim, C

    2017-06-01

    Triage imaging facilitates the timely recognition of acute stroke with prognostic implications. Improvement in MR acquisition speed is needed given the extreme time constraints before treatment. We compared an ultrafast Echo-Planar FLAIR sequence (EPI-FLAIR) and a conventional FLAIR sequence (cFLAIR) for their diagnostic performances and ability to estimate the age of infarction. Between June and August 2014, 125 consecutive patients (age 69±18 years, 48% men) admitted for a suspicion of acute (≤48-hrs) stroke were explored by both FLAIR sequences at 1.5-Tesla. EPI-FLAIR (15-sec) and cFLAIR (2-min and 15-sec) were compared by two readers, blinded to clinical data. EPI-FLAIR was less prone to kinetic artefacts than cFLAIR (2-3% vs. 23-49% depending on the reader, P0.9). Amongst 8 hemorrhages, one subarachnoid hemorrhage presenting as a sudden deficit was missed on EPI-FLAIR sequence. Amongst 60 infarctions, cFLAIR and EPI-FLAIR were concordant in 50 (83%), while signal changes were visible on cFLAIR only in the remaining 10 (17%) cases. Amongst the 43 patients with known onset time (n=17 within 4.5hrs), FLAIR-DWI mismatch identified<4.5-hrs infarction with the same sensitivity (65%) using cFLAIR and EPI-FLAIR, but the positive predictive value (PPV) was higher for cFLAIR than for EPI-FLAIR (73% vs. 50%, P=0.008). EPI-FLAIR allows a drastic reduction of acquisition time devoted to FLAIR sequence and minimizes motion artifacts. Compared with cFLAIR, it is however associated with increased risk of undiagnosed stroke mimics and lower PPV for identifying<4.5-hrs infarctions. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. FLAIR imaging for differential diagnosis of new cerebral microbleeds

    International Nuclear Information System (INIS)

    Watanabe, Akira

    2009-01-01

    It may be difficult to determine the time of appearance of cerebral microbleeds (MBs) in T2*-weighted MR imaging (MRI), because most MBs take more than several years to become absorbed. The presence of MBs is closely related to intracerebral hemorrhage, and it is important to detect new MBs in order to prevent intracerebral hemorrhage. We evaluated 108 patients on maintenance hemodialysis with MRI at least twice from May 2003 to May 2008. Seventy-two new MBs were detected and 59 MBs disappeared. Initial fluid-attenuated inversion recovery (FLAIR) imaging revealed 3 MBs with surrounding hyperintensity (SH), but follow-up FLAIR imaging demonstrated disappearance of the SH in all cases. Five of the 72 new MBs had SH, but follow-up FLAIR imaging demonstrated disappearance of the SH in all cases. In one case, SH with the enlarged MB disappeared in follow-up FLAIR images. In conclusion, we considered SH of new MBs to be vasogenic edema accompanying new intracerebral hemorrhage. It was useful to compare T2*-weighted MRI with FLAIR imaging to determine the differential diagnosis of new MBs. (author)

  11. FLAIR images of brain diseases

    International Nuclear Information System (INIS)

    Segawa, Fuminori; Kinoshita, Masao; Kishibayashi, Jun; Kamada, Kazuhiko; Sunohara, Nobuhiko.

    1994-01-01

    The present study was designed to assess the usefulness of fluid-attenuated inversion recovery (FLAIR) images in diagnosing brain diseases. The subjects were 20 patients with multiple cerebral infarction, multiple sclerosis, temporal epilepsy, or brain trauma, and 20 other healthy adults. FLAIR images, with a long repetitive time of 6000 msec and a long inversion time of 1400-1600 msec, showed low signal intensity in the cerebrospinal fluid in the lateral ventricles and the cerebral sulci, and high signal intensity in brain tissues. Signal intensity on FLAIR images correlated well with T2 relaxation times under 100 msec. For multiple sclerosis and cerebral infarction, cystic lesions, which were shown on T2-weighted images with long relaxation times over 100 msec, appeared as low-signal areas; and the lesions surrounding the cystic lesions appeared as high-signal areas. For temporal lobe epilepsy, the hippocampus was visualized as a high-signal area. Hippocampal lesions were demonstrated better with FLAIR images than with conventional T2-weighted and proton-density images. In a patient with cerebral trauma, FLAIR images revealed the lobulated structure with the residual cortex shown as a high signal area. The lesions surrounding the cystic change were imaged as high signal areas. These structural changes were demonstrated better with FLAIR images than with conventional T2-weighted sequences. FLAIR images were useful in detecting white matter lesions surrounding the lateral ventricles and cortical and subcortical lesions near the brain surface, which were unclear on conventional T2-weighted and proton-density images. (N.K.)

  12. High-speed imaging at 3 tesla. A technical and clinical review with an emphasis on whole-brain 3D imaging

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Kawai, Hisashi; Fukatsu, Hiroshi; Ishigaki, Takeo; Komada, Tomomi

    2005-01-01

    Improvements to the inherently high specific-absorption rate (SAR) of high-speed imaging at 3T are necessary in order to render this method clinically feasible. Various efforts have been undertaken to improve the associated hardware and software. In this review, we focus on whole-brain isotropic 3D imaging with a turbo spin-echo sequence with variable flip-angle echo trains (3D-TSE-VFL) and present its technical and clinical features. This sequence can be used to acquire images of various contrasts including T 2 -weighted, fat-suppressed T 2 -weighted, fluid-attenuated inversion recovery (FLAIR), fat-suppressed FLAIR, and STIR (short tau inversion recovery). Various aspects of 3D-TSE-VFL are discussed, including CSF (cerebrospinal fluid) and metal artifacts, STIR contrast, small-part visualization other than brain, and the possibility of serial subtraction. Some images from clinical cases are presented. (author)

  13. Estimation of gadolinium-induced T1-shortening with measurement of simple signal intensity ratio between the cochlea and brain parenchyma on 3D-FLAIR. Correlation with T1 measurement by TI scout sequence

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Ishihara, Shunichi; Iwano, Shingo; Kawai, Hisashi; Sone, Michihiko; Nakashima, Tsutomu

    2010-01-01

    The purpose of this study was to T 1 -shortening of labyrinthine fluid on 3-dimensional fluid-attenuated inversion recovery (3D-FLAIR) has been reported in many inner ear disorders. Although semi-quantitative assessment by simple signal intensity ratio between cochlear fluid and brain tissue has been tried, its feasibility using a multi-channel phased-array head coil with an inherently inhomogenous sensitivity distribution has not been fully evaluated. We evaluated the feasibility of measuring simple signal intensity ratio by correlating rapid T 1 measurements using an inversion time (TI) scout sequence. We evaluated 10 patients with Meniere's disease and 4 patients with sudden deafness. Nine of the patients with Meniere's disease received a unilateral intratympanic injection of gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA); the tenth patient received bilateral injections. The 4 patients with sudden deafness received a double-dose intravenous injection. Magnetic resonance (MR) images were obtained 24 hours after intratympanic injections and 4 hours after intravenous injections at 3 tesla using a 32-channel head coil. We measured the ratio (CM ratio) between the signal intensity of the perilymph in the cochlea (C) and that of the medulla oblongata (M) and correlated it with the null-point inversion time (TI null ) obtained with the TI scout sequence. The TI scout consisted of 85 images obtained with TI values between 132.5 and 3087.5 ms at increments of 37.5 ms. The correlation coefficient between TI null and the natural logarithm of the CM ratio was -0.88 (P<0.01). There was significant negative linear correlation. Measurement of the simple signal intensity ratio between the cochlea and the medulla can be used for semi-quantitative analysis of 3D-FLAIR. The results of this study may facilitate clinical research of inner-ear disease using 3D-FLAIR. (author)

  14. Pre- and postcontrast FLAIR MR imaging in the diagnosis of intracranial meningeal pathology

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Hachiya, Junichi

    2000-01-01

    Few reports address the use of fluid-attenuated inversion-recovery (FLAIR) images of the brain in the diagnosis of extraaxial lesions. Our purpose was to assess the value of FLAIR images, including postcontrast ones, in the diagnosis of intracranial meningeal diseases. We reviewed precontrast (n=24) and postcontrast (n=20) FLAIR images obtained from 25 patients with infectious meningitis (n=13), carcinomatous meningitis or dissemination of primary brain tumor (n=7), dural metastasis (n=3), and others (n=2) in comparison with fast spin-echo T2-weighted and postcontrast T1-weighted images. In lesion detectability, precontrast FLAIR images were significantly superior to fast spin-echo T2-weighted images but inferior to postcontrast T1-weighted images. There was no significant difference between postcontrast T1-weighted and FLAIR images. Precontrast FLAIR images can substitute for conventional fast spin-echo T2-weighted images. Postcontrast FLAIR images have diagnostic potential equivalent to conventional postcontrast T1-weighted images. (author)

  15. Contrast-enhanced FLAIR in the early diagnosis of infectious meningitis

    International Nuclear Information System (INIS)

    Splendiani, Alesssandra; Puglielli, Edoardo; Amicis, Rosanna De; Masciocchi, Carlo; Gallucci, Massimo; Necozione, Stefano

    2005-01-01

    We investigated the accuracy of MRI in the early diagnosis of infectious meningitis with emphasis on the value of gadolinium-enhanced fluid-attenuated inversion recovery (FLAIR) sequence. Twenty-seven patients with clinical suspicion of infectious meningitis were included. MRI was performed within 3 h of clinical evaluation. For all patients, T1-weighted spin-echo, dual-echo T2-weighted fast-spin-echo and FLAIR sequences were performed, followed by gadolinium-enhanced T1-weighted spin-echo and FLAIR sequences. Final diagnosis was based on the clinical findings and the analysis of cerebrospinal fluid, obtained by lumbar puncture after the MRI. Infectious meningitis was confirmed in 12 patients. In all of these patients of the plain studies, FLAIR was positive in only four patients. MRI gadolinium-enhanced FLAIR showed abnormal meningeal enhancement in all 12 patients, while gadolinium-enhanced T1-weighted spin-echo was positive only in six cases. There were no false-positive or false-negative results. It is concluded that MRI could have an important role in the early screening for infectious meningitis, provided a gadolinium-enhanced FLAIR sequence is used. (orig.)

  16. Contrast-enhanced FLAIR in the early diagnosis of infectious meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Splendiani, Alesssandra; Puglielli, Edoardo; Amicis, Rosanna De; Masciocchi, Carlo; Gallucci, Massimo [University of L' Aquila, Department of Radiology, L' Aquila (Italy); Necozione, Stefano [University of L' Aquila, Department of Statistic, L' Aquila (Italy)

    2005-08-01

    We investigated the accuracy of MRI in the early diagnosis of infectious meningitis with emphasis on the value of gadolinium-enhanced fluid-attenuated inversion recovery (FLAIR) sequence. Twenty-seven patients with clinical suspicion of infectious meningitis were included. MRI was performed within 3 h of clinical evaluation. For all patients, T1-weighted spin-echo, dual-echo T2-weighted fast-spin-echo and FLAIR sequences were performed, followed by gadolinium-enhanced T1-weighted spin-echo and FLAIR sequences. Final diagnosis was based on the clinical findings and the analysis of cerebrospinal fluid, obtained by lumbar puncture after the MRI. Infectious meningitis was confirmed in 12 patients. In all of these patients of the plain studies, FLAIR was positive in only four patients. MRI gadolinium-enhanced FLAIR showed abnormal meningeal enhancement in all 12 patients, while gadolinium-enhanced T1-weighted spin-echo was positive only in six cases. There were no false-positive or false-negative results. It is concluded that MRI could have an important role in the early screening for infectious meningitis, provided a gadolinium-enhanced FLAIR sequence is used. (orig.)

  17. Leptomeningeal high signal intensity (ivy sign) on fluid-attenuated inversion-recovery (FLAIR) MR images in moyamoya disease

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Hirokazu [Department of Diagnostic Radiology, School of Medicine, Keio University, Tokyo 1608582 (Japan)]. E-mail: hirokazu_fujiwara@ybb.ne.jp; Momoshima, Suketaka [Department of Diagnostic Radiology, School of Medicine, Keio University, Tokyo 1608582 (Japan); Kuribayashi, Sachio [Department of Diagnostic Radiology, School of Medicine, Keio University, Tokyo 1608582 (Japan)

    2005-08-01

    Purpose: There are a few reports on leptomeningeal high signal intensity (LMHI: ivy sign) on fluid-attenuated inversion-recovery (FLAIR) images in moyamoya disease, but the feature of this finding has not been completely understood. The purpose of this study was to characterize LMHI on FLAIR images in moyamoya disease and to assess usefulness of this finding in the diagnosis of moyamoya disease in conventional MR imaging. Material and methods: MR imaging of 28 patients with moyamoya disease was retrospectively reviewed. The grade of LMHI on FLAIR images was classified as 'absent,' 'minimal,' 'moderate' and 'marked.' Fifty-four hemispheres of 28 patients (2 patients had unilateral disease) were assessed for the frequency of visualization and distribution of LMHI. The correlations between LMHI on FLAIR images, moyamoya vessels on T1- and T2-weighted images and MR angiography findings were also analyzed. Results: Moderate and marked LMHI was seen in 31 out of 54 hemispheres (57%). LMHI was seen more prominently in the frontal and parietal lobes than in the temporal and occipital lobes. Although there was a tendency for LMHI on FLAIR images to be prominent in groups with moderate and marked moyamoya vessels on T1- and T2-weighted images, there was no significant correlation. More prominent LMHI was observed in the hemispheres in which cortical branches of the middle cerebral arteries were poorly visualized on MR angiography. Conclusion: Leptomeningeal high signal intensity (ivy sign) on FLAIR images is predominantly seen in the frontal and parietal lobes. Because this sign can be seen in patients with unremarkable moyamoya vessels, LMHI is a useful sign in conventional MR imaging for the diagnosis of moyamoya disease.

  18. Detecting subarachnoid hemorrhage: Comparison of combined FLAIR/SWI versus CT

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Rajeev Kumar, E-mail: rajeev.verma@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Kottke, Raimund, E-mail: raimund.kottke@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Andereggen, Lukas, E-mail: lukas.andereggen@insel.ch [Department of Neurosurgery, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Weisstanner, Christian, E-mail: christian.weisstanner@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Zubler, Christoph, E-mail: christoph.zubler@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Gralla, Jan, E-mail: jan.gralla@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Kiefer, Claus, E-mail: claus.kiefer@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Slotboom, Johannes, E-mail: johannes.slotboom@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); and others

    2013-09-15

    Objectives: Aim of this study was to compare the utility of susceptibility weighted imaging (SWI) with the established diagnostic techniques CT and fluid attenuated inversion recovery (FLAIR) in their detecting capacity of subarachnoid hemorrhage (SAH), and further to compare the combined SWI/FLAIR MRI data with CT to evaluate whether MRI is more accurate than CT. Methods: Twenty-five patients with acute SAH underwent CT and MRI within 6 days after symptom onset. Underlying pathology for SAH was head trauma (n = 9), ruptured aneurysm (n = 6), ruptured arteriovenous malformation (n = 2), and spontaneous bleeding (n = 8). SWI, FLAIR, and CT data were analyzed. The anatomical distribution of SAH was subdivided into 8 subarachnoid regions with three peripheral cisterns (frontal-parietal, temporal-occipital, sylvian), two central cisterns and spaces (interhemispheric, intraventricular), and the perimesencephalic, posterior fossa, superior cerebellar cisterns. Results: SAH was detected in a total of 146 subarachnoid regions. CT identified 110 (75.3%), FLAIR 127 (87%), and SWI 129 (88.4%) involved regions. Combined FLAIR and SWI identified all 146 detectable regions (100%). FLAIR was sensitive for frontal-parietal, temporal-occipital and Sylvian cistern SAH, while SWI was particularly sensitive for interhemispheric and intraventricular hemorrhage. Conclusions: By combining SWI and FLAIR, MRI yields a distinctly higher detection rate for SAH than CT alone, particularly due to their complementary detection characteristics in different anatomical regions. Detection strength of SWI is high in central areas, whereas FLAIR shows a better detection rate in peripheral areas.

  19. Usefulness of fluid attenuated inversion recovery(FLAIR) image in mesial temporal sclerosis : comparison with turbo spin-echo T2-weighted image

    Energy Technology Data Exchange (ETDEWEB)

    Son, Seok Hyun; Chang, Seung Kuk; Eun, Choong Ki [Pusan Paik Hospital, Inje Univ. College of Medicine, Kimhae (Korea, Republic of)

    1999-12-01

    To determine the usefulness of fluid attenuated inversion recovery(FLAIR) imaging for the in detection of high signal intensity of hippocampus or amygdala in mesial temporal sclerosis (MTS), compared with that of turbo spin-echo T2-weighted imaging. Two neuroradiologists independently analyzed randomly mixed MR images of 20 lesions of 17 patients in whom MTS had been diagnosed, and ten normal controls. All subjects underwent both who performed both FLAIR and turbo spin-echo T2-weighted imaging, in a blind fashion. In order to determine hippocampal morphology, oblique coronal images perpendicular to the long axis of the hippocampus were obtained. The detection rate of high signal intensity in hippocampus or amygdala, the radiologists' preferred imaging sequence, and intersubject consistency of detection were evaluated. Signal intensity in hippocampus or amygdala was considered high if substantially higher than signal intensity in the cortex of adjacent temporo-parietal lobe. In all normal controls, FLAIR and spin-echo T2-weighted images showed normal signal intensity in hippocampus or amygdala. In MTS, the mean detection rate of high signal intensity in hippocampus or amygdala, as seen on FLAIR images was 93%, compared with 43% on spin-echo T2-weighted images. In all cases in which signal intensity on FLAIR images was normal, signal intensity on spin-echo T2-weighted images was also normal. The radiologists preferred the contrast properties of FLAIR to those of spin-echo T2-weighted images. In the diagnosis of MTS using MRI, FLAIR images are more useful for the detection of high signal intensity of hippocampus or amygdala than are spin-echo T2-weighted images. In the diagnosis of MTS, FLAIR imaging is therefore a suitable alternative to spin-echo T2-weighted imaging.

  20. Usefulness of fluid attenuated inversion recovery(FLAIR) image in mesial temporal sclerosis : comparison with turbo spin-echo T2-weighted image

    International Nuclear Information System (INIS)

    Son, Seok Hyun; Chang, Seung Kuk; Eun, Choong Ki

    1999-01-01

    To determine the usefulness of fluid attenuated inversion recovery(FLAIR) imaging for the in detection of high signal intensity of hippocampus or amygdala in mesial temporal sclerosis (MTS), compared with that of turbo spin-echo T2-weighted imaging. Two neuroradiologists independently analyzed randomly mixed MR images of 20 lesions of 17 patients in whom MTS had been diagnosed, and ten normal controls. All subjects underwent both who performed both FLAIR and turbo spin-echo T2-weighted imaging, in a blind fashion. In order to determine hippocampal morphology, oblique coronal images perpendicular to the long axis of the hippocampus were obtained. The detection rate of high signal intensity in hippocampus or amygdala, the radiologists' preferred imaging sequence, and intersubject consistency of detection were evaluated. Signal intensity in hippocampus or amygdala was considered high if substantially higher than signal intensity in the cortex of adjacent temporo-parietal lobe. In all normal controls, FLAIR and spin-echo T2-weighted images showed normal signal intensity in hippocampus or amygdala. In MTS, the mean detection rate of high signal intensity in hippocampus or amygdala, as seen on FLAIR images was 93%, compared with 43% on spin-echo T2-weighted images. In all cases in which signal intensity on FLAIR images was normal, signal intensity on spin-echo T2-weighted images was also normal. The radiologists preferred the contrast properties of FLAIR to those of spin-echo T2-weighted images. In the diagnosis of MTS using MRI, FLAIR images are more useful for the detection of high signal intensity of hippocampus or amygdala than are spin-echo T2-weighted images. In the diagnosis of MTS, FLAIR imaging is therefore a suitable alternative to spin-echo T2-weighted imaging

  1. FLAIR images of mild head trauma with transient amnesia

    Energy Technology Data Exchange (ETDEWEB)

    Wakamoto, Hirooki; Miyazaki, Hiromichi; Inaba, Makoto; Ishiyama, Naomi [Hiratsuka City Hospital, Kanagawa (Japan); Kawase, Takeshi

    1998-11-01

    A newly advanced MRI pulse sequence, the FLAIR (fluid-attenuated inversion recovery) imaging, in which a long TE spin echo sequence is used with suppression of the CSF with an inversion pulse, displays the CSF space as a no signal intensity area. We examined 45 cases of mild head trauma with posttraumatic amnesia by FLAIR images and could detect some findings which could not be detected by CT scan and conventional MR images. These findings could be detected in many patients with long posttraumatic amnesia (over 2 hours), but they could not be detected in patients with short posttraumatic amnesia (within 30 mins). These findings existed surrounding lateral ventricles and we classified them into 3 types: type 1 is anterior horn of lateral ventricle, type 2 is the base of frontal lobe, and type 3 is cerebral deep white matter. Some of them were examined again by FLAIR images a month later, and these findings had disappeared. We suspect that these lesions were brain edema or mild contusion without hemorrhage. (author)

  2. FLAIR images of mild head trauma with transient amnesia

    International Nuclear Information System (INIS)

    Wakamoto, Hirooki; Miyazaki, Hiromichi; Inaba, Makoto; Ishiyama, Naomi; Kawase, Takeshi

    1998-01-01

    A newly advanced MRI pulse sequence, the FLAIR (fluid-attenuated inversion recovery) imaging, in which a long TE spin echo sequence is used with suppression of the CSF with an inversion pulse, displays the CSF space as a no signal intensity area. We examined 45 cases of mild head trauma with posttraumatic amnesia by FLAIR images and could detect some findings which could not be detected by CT scan and conventional MR images. These findings could be detected in many patients with long posttraumatic amnesia (over 2 hours), but they could not be detected in patients with short posttraumatic amnesia (within 30 mins). These findings existed surrounding lateral ventricles and we classified them into 3 types: type 1 is anterior horn of lateral ventricle, type 2 is the base of frontal lobe, and type 3 is cerebral deep white matter. Some of them were examined again by FLAIR images a month later, and these findings had disappeared. We suspect that these lesions were brain edema or mild contusion without hemorrhage. (author)

  3. MR imaging at 0.5 Tesla with FLAIR sequence in the diagnosis of acute subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Kopsa, W.; Leitner, H.; Tscholakoff, D.; Perneczky, G.

    1998-01-01

    Purpose: Evaluation of MR imaging in patients with acute subarachnoid hemorrhage (SAH) at 0.5 Tesla using the FLAIR (Fluid Attenuated Inversion Recovery) sequenze. Additionally, the value of MR angiographie (MRA) in the diagnosis of intracranial aneurysms was assessed. Materials and Methods: 19 patients with suspected acute SAH were included in this study. MR imaging was performed using an axial FLAIR sequence and axial T 1 , T 2 and PD weighted sequences. In 16 patients an additional MRA (3D-TOF) was performed. 10 patients without SAH were examined as a control group. At the end of the study the 29 MR examinations were randomised and the images were read by two experienced radiologists; subsequently a consensus interpretation was made. Results: In 16 patients an acute SAH was verified with the FLAIR sequence, in 13 cases the origin of hemorrhage was found during surgery. In the consensus interpretation of the MR images all cases were diagnosed properly. 12 of the 16 MRA studies were of diagnostic quality, but only 6 cases were interpreted correctly. Conclusion: The FLAIR sequence at 0.5 Tesla proved effective in the diagnosis of acute SAH. MRA at 0.5 Tesla failed in the detection of intracranial aneurysms. (orig.) [de

  4. Clinical utility of MR FLAIR imaging for head injuries

    Energy Technology Data Exchange (ETDEWEB)

    Ashikaga, Ryuichiro [Kinki Univ., Osaka-Sayama, Osaka (Japan). School of Medicine

    1996-12-01

    To study the utility of fluid attenuated inversion recovery (FLAIR) MR images in the evaluation of traumatic head injury, 56 patients with traumatic head injuries were examined with long TR/TE spin-echo (SE) sequences and FLAIR sequences. In 40 of them, long TR/short TE images were added to those sequences. Careful readings of MR images were done by two well-trained neuroradiologists. The chi-square test was used for statistical evaluation of our results. The relative sensitivities of FLAIR images were significantly better than those of long TR/TE, long TR/short TE images for the detection of diffuse axonal injury (p<0.01), cortical contusion (p<0.01), and subdural hematoma (p<0.01 for long TR/TE, p<0.05 for long TR/short TE). The number of cases of epidural hematoma and brainstem injury was too small for statistical significance to be determined. In 9 patients with corpus callosum injuries. FLAIR images demonstrated the lesions as abnormally high signal intensity in the septum pellucidum and fornix. Only sagittal FLAIR images could definitely discriminate the traumatic lesions of the fornix from the surrounding CSF. In addition, FLAIR images could easily discriminate DAI of the corpus callosum from CSF of the cavum velli interpositi. MR FLAIR images were found to be useful for detecting traumatic head injuries. (author)

  5. Regional Fluid-Attenuated Inversion Recovery (FLAIR at 7 Tesla correlates with Amyloid beta in Hippocampus and Brainstem of cognitively normal elderly subjects.

    Directory of Open Access Journals (Sweden)

    Simon J Schreiner

    2014-09-01

    Full Text Available Background: Accumulation of amyloid beta (Aβ may occur during healthy aging and is a risk factor for Alzheimer Disease (AD. While individual Aβ-accumulation can be measured non-invasively using Pittsburgh compound-B positron-emission-tomography (PiB-PET, Fluid-Attenuated Inversion Recovery (FLAIR is a Magnetic Resonance Imaging (MRI sequence, capable of indicating heterogeneous age-related brain pathologies associated with tissue-edema. In the current study cognitively normal elderly subjects were investigated for regional correlation of PiB- and FLAIR- intensity. Methods: 14 healthy elderly subjects without known history of cognitive impairment received 11C-PiB-PET for estimation of regional Aβ-load. In addition, whole brain T1-MPRAGE and FLAIR-MRI sequences were acquired at high field strength of 7 Tesla (7T. Volume-normalized intensities of brain regions were assessed by applying an automated subcortical segmentation algorithm for spatial definition of brain structures. Statistical dependence between FLAIR- and PiB-PET intensities was tested using Spearman's rank correlation coefficient (rho, followed by Holm-Bonferroni correction for multiple testing. Results: Neuropsychological testing revealed normal cognitive performance levels in all participants. Mean regional PiB-PET and FLAIR intensities were normally distributed and independent. Significant correlation between volume-normalized PiB-PET signals and FLAIR intensities resulted for Hippocampus (right:rho=0.86; left:rho=0.84, Brainstem (rho=0.85 and left Basal Ganglia vessel region (rho=0.82. Conclusions: Our finding of a significant relationship between PiB- and FLAIR-intensity mainly observable in the Hippocampus and Brainstem, indicates regional Aβ associated tissue-edema in cognitively normal elderly subjects. Further studies including clinical populations are necessary to clarify the relevance of our findings for estimating individual risk for age-related neurodegenerative

  6. Regional Fluid-Attenuated Inversion Recovery (FLAIR) at 7 Tesla correlates with amyloid beta in hippocampus and brainstem of cognitively normal elderly subjects

    Science.gov (United States)

    Schreiner, Simon J.; Liu, Xinyang; Gietl, Anton F.; Wyss, Michael; Steininger, Stefanie C.; Gruber, Esmeralda; Treyer, Valerie; Meier, Irene B.; Kälin, Andrea M.; Leh, Sandra E.; Buck, Alfred; Nitsch, Roger M.; Pruessmann, Klaas P.; Hock, Christoph; Unschuld, Paul G.

    2014-01-01

    Background: Accumulation of amyloid beta (Aβ) may occur during healthy aging and is a risk factor for Alzheimer Disease (AD). While individual Aβ-accumulation can be measured non-invasively using Pittsburgh Compund-B positron emission tomography (PiB-PET), Fluid-attenuated inversion recovery (FLAIR) is a Magnetic Resonance Imaging (MRI) sequence, capable of indicating heterogeneous age-related brain pathologies associated with tissue-edema. In the current study cognitively normal elderly subjects were investigated for regional correlation of PiB- and FLAIR intensity. Methods: Fourteen healthy elderly subjects without known history of cognitive impairment received 11C-PiB-PET for estimation of regional Aβ-load. In addition, whole brain T1-MPRAGE and FLAIR-MRI sequences were acquired at high field strength of 7 Tesla (7T). Volume-normalized intensities of brain regions were assessed by applying an automated subcortical segmentation algorithm for spatial definition of brain structures. Statistical dependence between FLAIR- and PiB-PET intensities was tested using Spearman's rank correlation coefficient (rho), followed by Holm–Bonferroni correction for multiple testing. Results: Neuropsychological testing revealed normal cognitive performance levels in all participants. Mean regional PiB-PET and FLAIR intensities were normally distributed and independent. Significant correlation between volume-normalized PiB-PET signals and FLAIR intensities resulted for Hippocampus (right: rho = 0.86; left: rho = 0.84), Brainstem (rho = 0.85) and left Basal Ganglia vessel region (rho = 0.82). Conclusions: Our finding of a significant relationship between PiB- and FLAIR intensity mainly observable in the Hippocampus and Brainstem, indicates regional Aβ associated tissue-edema in cognitively normal elderly subjects. Further studies including clinical populations are necessary to clarify the relevance of our findings for estimating individual risk for age-related neurodegenerative

  7. Clinical value of periventricular low-intensity areas detected by fluid attenuated inversion recovery (FLAIR). Relationships between perinatal vital parameter and neonatal MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kadowaki, Sachiko; Iwata, Osuke; Tamura, Masanori [Nagano Children' s Hospital, Toyoshina (Japan)] (and others)

    2002-01-01

    A follow-up study was performed to assess the correlation among the incidence of periventricular low intensities (PVLI) on MRI (magnetic resonance imaging) FLAIR (fluid attenuated inversion recovery) imaging, clinical evidence of perinatal insults that may cause white matter damage, and the outcome of the infants. We evaluated periventricular white matter lesions of 329 neonates whose MRI were obtained before two months corrected age. The detective rate of periventricular abnormalities on FLAIR imaging was significantly higher than that of T1-T2 weighted imaging. The most typical lesion detected on FLAIR imaging was periventricular low intensities (PVLI), frequently observed in the neonates with a history of preterm labour, very low birth weight, birth asphyxia and severe respiratory failure. Although we could not characterize the risk factors of PVLI, the incidence of PVLI had a strong correlation with the scores of motor and developmental tests at 12 and 36-months corrected age. In conclusion, FLAIR imaging, detecting the border zone damage of white matter, would be a strong tool to pick out neonates at high risk of neurological disturbances from those without clinical evidence of neurological insults in the neonatal period. (author)

  8. MRI of acute cerebral infarction: a comparison of FLAIR and T2-weighted fast spin-echo imaging

    International Nuclear Information System (INIS)

    Noguchi, K.; Ogawa, T.; Inugami, A.; Fujita, H.; Hatazawa, J.; Shimosegawa, E.; Okudera, T.; Uemura, K.; Seto, H.

    1997-01-01

    Fluid-attenuated inversion-recovery (FLAIR) sequences have been reported to provide high sensitivity to a wide range of central nervous system diseases. To our knowledge, however, FLAIR sequences have not been used to study patients with acute cerebral infarcts. We evaluated the usefulness of FLAIR sequences in this context. FLAIR sequences were acquired on a 0.5 T superconducting unit within 8 h of the onset in 19 patients (aged 26-80 years) with a total of 23 ischaemic lesions. The images were reviewed retrospectively by three neuroradiologists, and the FLAIR images were compared with T2-weighted fast spin-echo images. All but one of the ischaemic lesions involving grey matter was clearly demonstrated on FLAIR images as increased signal intensity in cortical or central grey matter. FLAIR images were particularly useful for detecting the hyperacute cortical infarcts within 3 h of onset, which were not readily detected on the spin-echo images. In 9 of 11 patients with complete proximal occlusion, the distal portion of the cerebral artery was visible as an area of high signal intensity on FLAIR images. (orig.). With 4 figs., 1 tab

  9. Contrast-enhanced flair imaging in the evaluation of infectious leptomeningeal diseases

    International Nuclear Information System (INIS)

    Parmar, Hemant; Sitoh, Y.-Y.; Anand, Pooja; Chua, Violet; Hui, Francis

    2006-01-01

    Purpose: The purpose of our study was to compare contrast-enhanced fluid-attenuated inversion recovery (FLAIR) images with contrast-enhanced T1 weighted images for infectious leptomeningitis. Materials and methods: We studied twenty-four patients with a clinical suspicion of infectious meningitis with unenhanced FLAIR, contrast-enhanced T1 weighted and contrast-enhanced FLAIR MR sequences. Twelve patients had cytologic and biochemical diagnosis of meningitis on cerebrospinal fluid (CSF) examination obtained 48 h before or after the MR study. Sequences were considered positive if abnormal signal was seen in the subarachnoid space (cistern or sulci) or along pial surface. Results: Twenty-seven examinations in 24 patients were performed. Of the 12 patients (thirteen studies) in whom cytology was positive, unenhanced FLAIR images were positive in six cases (sensitivity 46%), contrast-enhanced FLAIR images were positive in 11 (sensitivity 85%), and contrast-enhanced T1 weighted MR images were positive in 11 patients (sensitivity 85%). Of the 12 patients (14 studies) in whom cerebrospinal fluid study was negative, unenhanced FLAIR images were negative in 13, contrast-enhanced FLAIR images were negative in 11, and contrast-enhanced T1 weighted MR images were negative in eight. Thus, the specificity of unenhanced FLAIR, contrast-enhanced FLAIR and contrast-enhanced T1 weighted images was 93, 79 and 57%, respectively. Conclusion: Our results suggest that post-contrast FLAIR images have similar sensitivity but a higher specificity compared to contrast-enhanced T1 weighted images for detection of leptomeningeal enhancement. It can be a useful adjunct to post-contrast T1 weighted images in evaluation of infectious leptomeningitis

  10. Contrast-enhanced flair imaging in the evaluation of infectious leptomeningeal diseases

    Energy Technology Data Exchange (ETDEWEB)

    Parmar, Hemant [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore) and Department of Diagnostic Imaging, Hospital for Sick Children, Toronto (Canada)]. E-mail: parurad@hotmail.com; Sitoh, Y.-Y. [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Anand, Pooja [Department of Neurology, National Neuroscience Institute, 11 Jalan Tan Tock Seng (Singapore); Chua, Violet [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Hui, Francis [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore)

    2006-04-15

    Purpose: The purpose of our study was to compare contrast-enhanced fluid-attenuated inversion recovery (FLAIR) images with contrast-enhanced T1 weighted images for infectious leptomeningitis. Materials and methods: We studied twenty-four patients with a clinical suspicion of infectious meningitis with unenhanced FLAIR, contrast-enhanced T1 weighted and contrast-enhanced FLAIR MR sequences. Twelve patients had cytologic and biochemical diagnosis of meningitis on cerebrospinal fluid (CSF) examination obtained 48 h before or after the MR study. Sequences were considered positive if abnormal signal was seen in the subarachnoid space (cistern or sulci) or along pial surface. Results: Twenty-seven examinations in 24 patients were performed. Of the 12 patients (thirteen studies) in whom cytology was positive, unenhanced FLAIR images were positive in six cases (sensitivity 46%), contrast-enhanced FLAIR images were positive in 11 (sensitivity 85%), and contrast-enhanced T1 weighted MR images were positive in 11 patients (sensitivity 85%). Of the 12 patients (14 studies) in whom cerebrospinal fluid study was negative, unenhanced FLAIR images were negative in 13, contrast-enhanced FLAIR images were negative in 11, and contrast-enhanced T1 weighted MR images were negative in eight. Thus, the specificity of unenhanced FLAIR, contrast-enhanced FLAIR and contrast-enhanced T1 weighted images was 93, 79 and 57%, respectively. Conclusion: Our results suggest that post-contrast FLAIR images have similar sensitivity but a higher specificity compared to contrast-enhanced T1 weighted images for detection of leptomeningeal enhancement. It can be a useful adjunct to post-contrast T1 weighted images in evaluation of infectious leptomeningitis.

  11. Three-dimensional fluid-attenuated inversion recovery sequence for visualisation of subthalamic nucleus for deep brain stimulation in Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Young Jin [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology, Research Institute of Radiology, Seoul (Korea, Republic of); Inje University, Department of Radiology, Busan Paik Hospital, Busan (Korea, Republic of); Kim, Sang Joon; Kim, Ho Sung; Choi, Choong Gon; Jung, Seung Chai [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology, Research Institute of Radiology, Seoul (Korea, Republic of); Lee, Jung Kyo [University of Ulsan College of Medicine, Asan Medical Center, Department of Neurosurgery, Seoul (Korea, Republic of); Lee, Chong Sik; Chung, Sun J. [University of Ulsan College of Medicine, Asan Medical Center, Department of Neurology, Seoul (Korea, Republic of); Cho, So Hyun [Department of Radiology, Busan (Korea, Republic of); Lee, Gyoung Ro [Philips HealthCare Korea, Seoul (Korea, Republic of)

    2015-09-15

    Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an accepted treatment for advanced Parkinson's disease (PD). However, targeting the STN is difficult due to its relatively small size and variable location. The purpose of this study was to assess which of the following sequences obtained with the 3.0 T MR system can accurately delineate the STN: coronal 3D fluid-attenuated inversion recovery (FLAIR), 2D T2*-weighted fast-field echo (T2*-FFE) and 2D T2-weighted turbo spin-echo (TSE) sequences. We included 20 consecutive patients with PD who underwent 3.0 T MR for DBS targeting. 3D FLAIR, 2D T2*-FFE and T2-TSE images were obtained for all study patients. Image quality and demarcation of the STN were analysed using 4-point scales, and contrast ratio (CR) of the STN and normal white matter was calculated. The Friedman test was used to compare the three sequences. In qualitative analysis, the 2D T2*-FFE image showed more artefacts than 3D FLAIR or 2D T2-TSE, but the difference did not reach statistical significance. 3D FLAIR images showed significantly superior demarcation of the STN compared with 2D T2*-FFE and T2-TSE images (P < 0.001, respectively). The CR of 3D FLAIR was significantly higher than that of 2D T2*-FFE or T2-TSE images in multiple comparison correction (P < 0.001), but there was no significant difference in the CR between 2D T2*-FFE and T2-TSE images. Coronal 3D FLAIR images showed the most accurate demarcation of the STN for DBS targeting among coronal 3D FLAIR, 2D T2*-FFE and T2-TSE images. (orig.)

  12. Three-dimensional fluid-attenuated inversion recovery sequence for visualisation of subthalamic nucleus for deep brain stimulation in Parkinson's disease

    International Nuclear Information System (INIS)

    Heo, Young Jin; Kim, Sang Joon; Kim, Ho Sung; Choi, Choong Gon; Jung, Seung Chai; Lee, Jung Kyo; Lee, Chong Sik; Chung, Sun J.; Cho, So Hyun; Lee, Gyoung Ro

    2015-01-01

    Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an accepted treatment for advanced Parkinson's disease (PD). However, targeting the STN is difficult due to its relatively small size and variable location. The purpose of this study was to assess which of the following sequences obtained with the 3.0 T MR system can accurately delineate the STN: coronal 3D fluid-attenuated inversion recovery (FLAIR), 2D T2*-weighted fast-field echo (T2*-FFE) and 2D T2-weighted turbo spin-echo (TSE) sequences. We included 20 consecutive patients with PD who underwent 3.0 T MR for DBS targeting. 3D FLAIR, 2D T2*-FFE and T2-TSE images were obtained for all study patients. Image quality and demarcation of the STN were analysed using 4-point scales, and contrast ratio (CR) of the STN and normal white matter was calculated. The Friedman test was used to compare the three sequences. In qualitative analysis, the 2D T2*-FFE image showed more artefacts than 3D FLAIR or 2D T2-TSE, but the difference did not reach statistical significance. 3D FLAIR images showed significantly superior demarcation of the STN compared with 2D T2*-FFE and T2-TSE images (P < 0.001, respectively). The CR of 3D FLAIR was significantly higher than that of 2D T2*-FFE or T2-TSE images in multiple comparison correction (P < 0.001), but there was no significant difference in the CR between 2D T2*-FFE and T2-TSE images. Coronal 3D FLAIR images showed the most accurate demarcation of the STN for DBS targeting among coronal 3D FLAIR, 2D T2*-FFE and T2-TSE images. (orig.)

  13. Voxel based morphometry of FLAIR MRI in children with intractable focal epilepsy: Implications for surgical intervention

    International Nuclear Information System (INIS)

    Riney, Catherine J.; Chong, William K.; Clark, Chris A.; Cross, J. Helen

    2012-01-01

    Purpose: Magnetic resonance imaging (MRI), in particular fluid-attenuated inversion-recovery (FLAIR), has transformed the delineation of structural brain pathology associated with focal epilepsy. However, to date there is no literature on voxel based morphometry (VBM) of FLAIR in children with epilepsy. The aim of this study was to explore the role of visual and VBM assessment of FLAIR in pre-operative investigation of children with intractable focal epilepsy. Methods: Children with intractable epilepsy due to focal cortical dysplasia (FCD) and children with intractable cryptogenic focal epilepsy (CFE) were investigated. FLAIR and T1-weighted MRI were acquired on a 1.5T MRI scanner (Siemens, Erlangen, Germany). VBM was performed using SPM5 (Wellcome Institute of Cognitive Neuroscience, London). Results: Eight children with FCD (M = 5, age 7.9–17.3 years) and 14 children with CFE (M = 8, 7.8–16.8 years) were enrolled. VBM of FLAIR detected 7/8 (88%) of FCD whilst VBM of T1-weighted MRI detected only 3/8 (38%) FCD. VBM of FLAIR detected abnormality in 4/14 children with CFE, in 2/14 (14%) the abnormality was concordant with other data on the epileptogenic zone and with visible abnormality on repeat visual inspection of MR data. VBM of T1-weighed MRI detected abnormality in 2/14 children with CFE, none of which correlated with visible abnormality. Discussion: This study highlights the important role that FLAIR imaging has in the pre-operative assessment of children with intractable epilepsy. VBM of FLAIR may provide important information allowing selection of children with intractable CFE who are likely to benefit from further neuroradiological or neurophysiological evaluation.

  14. Edge Contrast of the FLAIR Hyperintense Region Predicts Survival in Patients with High-Grade Gliomas following Treatment with Bevacizumab.

    Science.gov (United States)

    Bahrami, N; Piccioni, D; Karunamuni, R; Chang, Y-H; White, N; Delfanti, R; Seibert, T M; Hattangadi-Gluth, J A; Dale, A; Farid, N; McDonald, C R

    2018-04-05

    Treatment with bevacizumab is standard of care for recurrent high-grade gliomas; however, monitoring response to treatment following bevacizumab remains a challenge. The purpose of this study was to determine whether quantifying the sharpness of the fluid-attenuated inversion recovery hyperintense border using a measure derived from texture analysis-edge contrast-improves the evaluation of response to bevacizumab in patients with high-grade gliomas. MRIs were evaluated in 33 patients with high-grade gliomas before and after the initiation of bevacizumab. Volumes of interest within the FLAIR hyperintense region were segmented. Edge contrast magnitude for each VOI was extracted using gradients of the 3D FLAIR images. Cox proportional hazards models were generated to determine the relationship between edge contrast and progression-free survival/overall survival using age and the extent of surgical resection as covariates. After bevacizumab, lower edge contrast of the FLAIR hyperintense region was associated with poorer progression-free survival ( P = .009) and overall survival ( P = .022) among patients with high-grade gliomas. Kaplan-Meier curves revealed that edge contrast cutoff significantly stratified patients for both progression-free survival (log-rank χ 2 = 8.3, P = .003) and overall survival (log-rank χ 2 = 5.5, P = .019). Texture analysis using edge contrast of the FLAIR hyperintense region may be an important predictive indicator in patients with high-grade gliomas following treatment with bevacizumab. Specifically, low FLAIR edge contrast may partially reflect areas of early tumor infiltration. This study adds to a growing body of literature proposing that quantifying features may be important for determining outcomes in patients with high-grade gliomas. © 2018 by American Journal of Neuroradiology.

  15. Uso da sequência FLAIR-EPI na análise da esclerose mesial temporal EPI-FLAIR sequence in the evaluation of mesial temporal sclerosis

    Directory of Open Access Journals (Sweden)

    Marcos Alberto da Costa Machado Júnior

    2001-06-01

    Full Text Available O objetivo deste estudo é analisar as alterações morfológicas e de intensidade de sinal das regiões hipocampais em pacientes, com epilepsia temporal fármaco-resistente. Para tal, estudamos 8 pacientes com esclerose mesial temporal, utilizando aparelhagem de RM de 1,5T, com sequências Spin Eco - SE, Fast Spin Eco - FSE, Fluid Atenuation Inversion Recovery, com Eco Planar Imaging - FLAIR-EPI. Observamos a superioridade da sequência FLAIR na detecção do aumento da intensidade de sinal da região hipocampal, particularmente com cortes coronais, em relação às sequências SE e FSE, com a vantagem de ser uma técnica de rápida execução. A sequência STIR evidenciou adelgaçamento da cortical do hipocampo, na metade dos casos que apresentavam alteração de sinal.The purpose of this study is to evaluate morpholologycal and signal intensity changes in the hippocampus in patients with medically intractable temporal lobe epilepsy. We studied 8 patients with mesial temporal sclerosis using a 1.5 -T MR and the following sequences Spin Eco- SE, Fast Spin Echo- FSE, Fluid Atenuation Inversion Recovery Echo Planar Imaging - FLAIR-EPI. We noticed a sensitive increase signal intensity on FLAIR- EPI sequences, particularly, in coronal images, than on SE and FSE sequences. The STIR sequence showed a cortical hippocampus atrophy in half of the cases, in whom signal abnormalities were present.

  16. FLAIR MR sequence in the diagnosis and follow-up of low-grade astrocytomas

    Directory of Open Access Journals (Sweden)

    Stošić-Opinćal Tatjana

    2005-01-01

    Full Text Available Aim. To evaluate the sensitivity of fluid-attenuated inversion recovery (FLAIR sequence in the diagnosis and follow-up of the patients with low-grade astrocytomas compared with T2-weighted (T2W sequence. Methods. Twenty-four patients with biopsy- confirmed low-grade astrocytoma (age range, 15-66 years underwent T1- weighted (T1W, T2W and FLAIR imaging with a superconducting unit 1.0 T. FLAIR images were qualitatively evaluated by comparison with T2W images by the three experienced neuroradiologists. To evaluate the diagnostic value of FLAIR, the neuroradiologists individually assessed the possibilities of the detection of lesions, as well as the possibilities of the differentiation of tumor from the surrounding edema on FLAIR vs. T2W images. Every examiner ranked FLAIR sequence vs. T2W in three degrees: worse, equal and better. Results. The comparison of FLAIR with T2W spin-echo (SE images with regard to the detection of the lesions showed that 82.8% of FLAIR studies were superior, 17.2% were of similar diagnostic value, and none was inferior to the T2W images. The comparison of images with regard to the differentiation of tumor boundaries vs. surrounding edema showed that 92.5% of FLAIR studies were superior, 7.5% were of similar diagnostic value, and none was inferior to the T2W images. Conclusion. Our results were similar to the previous studies' results concerning the advantages of FLAIR sequence in the diagnosis of low grade astrocytomas over T2W sequence. FLAIR was better at showing different tumor components, and at distinguishing CSF from the cystic component, and the postoperative cavity, compared with T2W images. Our conclusion was that FLAIR could be routinely used in the evaluation and follow-up of low-grade astrocytomas.

  17. Flair MR imaging in the Detection of subarachnoid hemorrhage : comparison with CT and T1-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Min, Soo Hyun; Kim, Soo Youn; Lee, Ghi Jai; Shim, Jae Chan; Oh, Tae Kyung; Kim, Ho Kyun [College of Medicine, Jnje University, Seoul (Korea, Republic of)

    2000-03-01

    To compare the findings of fluid-attenuated inversion recovery (FLAIR) MR imaging in the detection of subarachnoid hemorrhage (SAH), with those of precontrast CT and T1-weighted MR imaging. In 13 patients (14 cases) with SAH, FLAIR MR images were retrospectively analyzed and compared with CT (10 patients, 11 cases) and T1-weighted MR images (9 cases). SAH was confirmed on the basis of high density along the subarachnoid space, as seen on precontrast CT, or lumbar puncture. MR imaging was performed on a 1.0T unit. FLAIR MR and CT images were obtained during the acute stage(less than 3 days after ictus) in 10 and 9 cases, respectively, during the subacute stage (4-14 days after ictus) in two cases and one, respectively, and during the chronic stage (more than 15 days after ictus) in two cases and one, respectively. CT was performed before FLAIR MR imaging, and the interval between CT and FLAIR ranged from 24 hours (6 cases) to 2-3 (2 cases) or 4-7 days (3 cases). In each study, the conspicuity of visualization of SAH was graded as excellent, good, fair, or negative at five locations (sylvian fissure, cortical sulci, anterior basal cistern, posterior basal cistern, and perimesencephalic cistern). In all cases, subarachnoid hemorrhages were demonstrated as high signal intensity areas on FLAIR images. The detection rates for SAH on CT and T1-weighted MR images were 100% (11/11) and 89% (8/9), respectively. FLAIR was superior to T1-weighted imaging in the detection of SAH at all sites except the anterior basal cistern (p less than 0.05) and superior to CT in the detection of SAH at the cortical sulci (p less than 0.05). On FLAIR MR images, subarachnoid hemorrhages at all stages are demonstrated as high signal intensity areas; the FLAIR MR sequence is thus considered useful in the detection of SAH. In particular FLAIR is more sensitive than CT for the detection of SAH in the cortical sulci. (author)

  18. Evaluation of Possible Prognostic Factors of Fulminant Acute Disseminated Encephalomyelitis (ADEM) on Magnetic Resonance Imaging with Fluid-Attenuated Inversion Recovery (FLAIR) and Diffusion-Weighted Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Donmez, F.Y.; Aslan, H.; Coskun, M. (Dept. of Radiology, Faculty of Medicine, Baskent Univ., Ankara (Turkey))

    2009-04-15

    Background: Acute disseminated encephalomyelitis (ADEM) may be a rapidly progressive disease with different clinical outcomes. Purpose: To investigate the radiological findings of fulminant ADEM on diffusion-weighted imaging (DWI) and fluid-attenuated inversion recovery (FLAIR) images, and to correlate these findings with clinical outcome. Material and Methods: Initial and follow-up magnetic resonance imaging (MRI) scans in eight patients were retrospectively evaluated for distribution of lesions on FLAIR images and presence of hemorrhage or contrast enhancement. DWI of the patients was evaluated as to cytotoxic versus vasogenic edema. The clinical records were analyzed, and MRI results and clinical outcome were correlated. Results: Four of the eight patients died, three had full recovery, and one had residual cortical blindness. The distribution of the hyperintense lesions on FLAIR sequence was as follows: frontal (37.5%), parietal (50%), temporal (37.5%), occipital (62.5%), basal ganglia (50%), pons (37.5%), mesencephalon (37.5%), and cerebellum (50%). Three of the patients who died had brainstem involvement. Two patients had a cytotoxic edema, one of whom died, and the other developed cortical blindness. Six patients had vasogenic edema: three of these patients had a rapid progression to coma and died; three of them recovered. Conclusion: DWI is not always helpful for evaluating the evolution or predicting the outcome of ADEM. However, extension of the lesions, particularly brainstem involvement, may have an influence on the prognosis.

  19. FLAIR imaging for multiple sclerosis: a comparative MR study at 1.5 and 3.0 Tesla

    International Nuclear Information System (INIS)

    Bachmann, Rainald; Reilmann, Ralf; Schwindt, Wolfram; Kugel, Harald; Heindel, Walter; Kraemer, Stefan

    2006-01-01

    The purpose of this study was (1) to identify the optimal TE for FLAIR-imaging at 3.0 T assessing three different echo times qualitatively and quantitatively and (2) to evaluate the diagnostic efficacy of high-field 3.0-T FLAIR imaging in comparison to conventional 1.5-T MRI in patients with multiple sclerosis (MS). Twenty-two patients with clinically definite MS underwent axial FLAIR imaging at 1.5 and 3.0 T. In 15 of these patients further FLAIR images with a TE of 100, 120 and 140 ms were acquired at 3.0 T. Imaging protocols were modified for 3.0 T using the increased SNR to acquire more and thinner slices while maintaining a comparable scan time. FLAIR images of either different TEs or different field strengths were ranked for each patient qualitatively by two observers. Signal intensity measurements were obtained in the gray and white matter, CSF and representative white matter lesions (WML). At 3.0 T, a TE of 100 and 120 ms proved superior in all qualitative categories when compared to 140 ms. In the quantitative assessment CNR of WML was highest for 120 ms (CNR: 19.8), intermediate for 100 ms (17.2) and lowest for 140 ms (15.3) (P<0.003). For lesion conspicuity and overall image quality, 3.0 T was judged superior to 1.5 T, whereas no difference was found for gray-white differentiation and image noise. With regard to artifacts, 3.0 T was inferior to 1.5 T. The CNR for WML was slightly lower at 3.0 T, but the difference was not significant (22.6 vs. 28.0, P=ns). (orig.)

  20. Usefulness of combined fat- and fluid-suppressed SPIR-FLAIR images in optic neurits : Comparison with fat-suppressed SPIR or STIR images

    International Nuclear Information System (INIS)

    Kim, Hye Yeon; Son, Seok Hyun; Eun, Choong Ki; Han, Sang Suk

    2001-01-01

    To compare the usefulness of combined fat- and fluid-suppressed selective partial inversion recovery-fluid attenuated inversion recovery(SPIR-FLAIR) images in the detection of high signal intensity of the optic nerve in optic neuritis with that of fat-suppressed selective partial inversion recovery(SPIR) or short inversion time inversion recovery(STIR) images. Two radiologists independently analyzed randomly mixed MR images of 16 lesions in 14 patients (M:F=7:7; mean age, 40 years) in whom optic neuritis had been clinically diagnosed. All subjects underwent both SPIR-FLAIR and fat-suppressed SPIR or STIR imaging, in a blind fashion. In order to evaluate the optic nerve, coronal images perpendicular to its long axis were obtained. The detection rate of high signal intensity of the optic nerve, the radiologists preferred imaging sequences, and intersubject consistency of detection were evaluated. 'High signal intensity' was defined as the subjective visual evaluation of increased signal intensity compared with that of the contralateral optic nerve or that of white matter. The mean detection rate of high signal intensity of the optic nerve was 90% for combined fat- and fluid-suppressed SPIR-FLAIR images, and 59% for fat-suppressed SPIR or STIR images. In all cases in which the signal intensity observed on SPIR-FLAIR images was normal, that on fat-suppressed SPIR or STIR images was also normal. The radiologists preferred the contrast properties of SPIR-FLAIR to those of fat-suppressed SPIR or STIR images. In the diagnosis of optic neuritis using MRI, combined fat- and fluid-suppressed SPIR-FLAIR images were more useful for the detection of high signal intensity of the optic nerve than fat-suppressed SPIR or STIR images. For the evaluation of optic neuritis, combined fat- and fluid-suppressed SPIR-FLAIR imaging is superior to fat-suppressed SPIR or STIR imaging

  1. Diagnostic value of the fast-FLAIR sequence in MR imaging of intracranial tumors

    International Nuclear Information System (INIS)

    Husstedt, H.W.; Sickert, M.; Koestler, H.; Haubitz, B.; Becker, H.

    2000-01-01

    The aim of this study was to quantify imaging characteristics of fast fluid-attenuated inversion recovery (FLAIR) sequence in brain tumors compared with T1-postcontrast- and T2-sequences. Fast-FLAIR-, T2 fast spin echo (FSE)-, and T1 SE postcontrast images of 74 patients with intracranial neoplasms were analyzed. Four neuroradiologists rated signal intensity and inhomogeneity of the tumor, rendering of cystic parts, demarcation of the tumor vs brain, of the tumor vs edema and of brain vs edema, as well as the presence of motion and of other artifacts. Data analysis was performed for histologically proven astrocytomas, glioblastomas, and meningiomas, for tumors with poor contrast enhancement, and for all patients pooled. Only for tumors with poor contrast enhancement (n = 12) did fast FLAIR provide additional information about the lesion. In these cases, signal intensity, demarcation of the tumor vs brain, and differentiation of the tumor vs edema were best using fast FLAIR. In all cases, rendering of the tumor's inner structure was poor. For all other tumor types, fast FLAIR did not give clinically relevant information, the only exception being a better demarcation of the edema from brain tissue. Artifacts rarely interfered with evaluation of fast-FLAIR images. Thus, fast FLAIR cannot replace T2-weighted series. It provides additional information only in tumors with poor contrast enhancement. It is helpful for defining the exact extent of the edema of any tumor but gives little information about their inner structure. (orig.)

  2. Diagnostic value of the fast-FLAIR sequence in MR imaging of intracranial tumors.

    Science.gov (United States)

    Husstedt, H W; Sickert, M; Köstler, H; Haubitz, B; Becker, H

    2000-01-01

    The aim of this study was to quantify imaging characteristics of fast fluid-attenuated inversion recovery (FLAIR) sequence in brain tumors compared with T1-postcontrast- and T2-sequences. Fast-FLAIR-, T2 fast spin echo (FSE)-, and T1 SE postcontrast images of 74 patients with intracranial neoplasms were analyzed. Four neuroradiologists rated signal intensity and inhomogeneity of the tumor, rendering of cystic parts, demarcation of the tumor vs brain, of the tumor vs edema and of brain vs edema, as well as the presence of motion and of other artifacts. Data analysis was performed for histologically proven astrocytomas, glioblastomas, and meningiomas, for tumors with poor contrast enhancement, and for all patients pooled. Only for tumors with poor contrast enhancement (n = 12) did fast FLAIR provide additional information about the lesion. In these cases, signal intensity, demarcation of the tumor vs brain, and differentiation of the tumor vs edema were best using fast FLAIR. In all cases, rendering of the tumor's inner structure was poor. For all other tumor types, fast FLAIR did not give clinically relevant information, the only exception being a better demarcation of the edema from brain tissue. Artifacts rarely interfered with evaluation of fast-FLAIR images. Thus, fast FLAIR cannot replace T2-weighted series. It provides additional information only in tumors with poor contrast enhancement. It is helpful for defining the exact extent of the edema of any tumor but gives little information about their inner structure.

  3. Diagnosis of acute subarachnoid hemorrhage at 1.5 Tesla using proton-density weighted FSE and FLAIR sequences

    International Nuclear Information System (INIS)

    Wiesmann, M.; Mayer, T.E.; Brueckmann, H.; Medele, R.

    1999-01-01

    Purpose: To evaluate MR imaging at 1.5 Tesla in patients suffering from acute subarachnoid hemorrhage (SAH) using proton-density weighted (PDW) fast spin echo (FSE) and fluid attenuated inversion recovery (FLAIR) sequences. Methods: 19 patients suffering from acute SAH as diagnosed by CT were studied 6 h to 3 days after hemorrhage. 10 patients without SAH were studied as a control group. The presence of subarachnoid blood as well as possible artifacts was recorded. Results: In all 19 patients subarachnoid hemorrhage was detected on both FLAIR and PDW images (100%). On the FLAIR images, the cerebral ventricles were partially obscured by flow artifacts in 7 of 19 patients, the basal cisterns in 6 of 19 patients. In 4 of these 13 regions blood was diagnosed on both PDW and CT images, while in the other 9 regions both PDW and CT were unremarkable. Conclusion: The sensitivity of MRI at 1.5 Tesla in the diagnosis of subarachnoid hemorrhage is comparable to CT. The combination of FLAIR and PDW FSE sequences helps to avoid false-positive results caused by flow artifacts. (orig.) [de

  4. FLAIR vascular hyperintensities and dynamic 4D angiograms for the estimation of collateral blood flow in posterior circulation occlusion

    International Nuclear Information System (INIS)

    Foerster, Alex; Wenz, Holger; Kerl, Hans Ulrich; Al-Zghloul, Mansour; Habich, Sonia; Groden, Christoph

    2014-01-01

    The objectives of this paper are to assess collateral blood flow in posterior circulation occlusion by MRI-based approaches (fluid-attenuated inversion recovery (FLAIR) vascular hyperintensities (FVHs), collateralization on dynamic 4D angiograms) and investigate its relation to ischemic lesion size and growth. In 28 patients with posterior cerebral artery (PCA) and 10 patients with basilar artery (BA) occlusion, MRI findings were analyzed, with emphasis on distal FVH and collateralization on dynamic 4D angiograms. In PCA occlusion, distal FVH was observed in 18/29 (62.1 %), in BA occlusion, in 8/10 (80 %) cases. Collateralization on dynamic 4D angiograms was graded 1 in 8 (27.6 %) patients, 2 in 1 (3.4 %) patient, 3 in 12 (41.4 %) patients, and 4 in 8 (27.6 %) patients with PCA occlusion and 0 in 1 (10 %) patient, 2 in 3 (30 %) patients, 3 in 1 (10 %) patient, and 4 in 5 (50 %) patients with BA occlusion. FVH grade showed neither correlation with initial or follow-up diffusion-weighted image (DWI) lesion size nor DWI-perfusion-weighted imaging (PWI) mismatch ratio. Collateralization on dynamic 4D angiograms correlated inversely with initial DWI lesion size and moderately with the DWI-(PWI) mismatch ratio. The combination of distal FVH and collateralization grade on dynamic 4D angiograms correlated inversely with initial as well as follow-up DWI lesion size and highly with the DWI-PWI mismatch ratio. In posterior circulation occlusion, FVH is a frequent finding, but its prognostic value is limited. Dynamic 4D angiograms are advantageous to examine and graduate collateral blood flow. The combination of both parameters results in an improved characterization of collateral blood flow and might have prognostic relevance. (orig.)

  5. Parallel Processor for 3D Recovery from Optical Flow

    Directory of Open Access Journals (Sweden)

    Jose Hugo Barron-Zambrano

    2009-01-01

    Full Text Available 3D recovery from motion has received a major effort in computer vision systems in the recent years. The main problem lies in the number of operations and memory accesses to be performed by the majority of the existing techniques when translated to hardware or software implementations. This paper proposes a parallel processor for 3D recovery from optical flow. Its main feature is the maximum reuse of data and the low number of clock cycles to calculate the optical flow, along with the precision with which 3D recovery is achieved. The results of the proposed architecture as well as those from processor synthesis are presented.

  6. Usefulness of low-field FlAIR sequence in MR imaging of intracranial tumors

    International Nuclear Information System (INIS)

    Sokolowska, D.; Sasiadek, M.; Zimny, A.

    2004-01-01

    Plain MR study is often insufficient for visualization of all important details of intracranial tumors, hence there are attempts to use supplementary MR techniques. One of them is FLAIR (fluid attenuated inversion recovery) sequence which previously was available only in high-field MR units, but recently has been introduced also in less expensive low-field units. FLAIR is already widely used in the diagnostics of ischemic and demyelinating lesions, while there are few papers concerning its application in intracranial tumors, none of them regarding low-field MR units.The aim of our study was detailed evaluation of low-field FLAIR in the diagnostics of intracranial tumors. The material consisted of 76 patients with intracranial tumors, who were examined with low-field open MR unit (0.23 Tesla). In all patients, standard T2-weighted and T1-weighted (before and after contrast enhancement) sequences, as well as FLAIR sequence, were performed. The following symptoms were compared in the aforementioned sequences: tumor-edema, edema-brain and tumor-brain borders, visualization of tumour structure, vessels in the tumor area and precise tumor localization. A superiority of FLAIR in assessment of all symptoms has been confirmed, at least in part of the patient group. It concerned particularly the evaluation of brain-edema and edema-brain borders which were better visible with FLAIR than with all other sequences in 29 and 30 patients, respectively. In the assessment of the remaining symptoms (tumor-brain border, tumor structure, visualization of vessels, tumor localization) FLAIR was superior to other sequences in smaller number of patients (13,11,11 and 12, respectively). Totally, in 48 out of 76 patients (63.2%) FLAIR allowed better assessment of at least one of the analyzed symptoms. Low-field MR FLAIR enriches diagnostic information in majority of patients with intracranial tumors, therefore it should be included routinely in the diagnostic algorithm in this group of

  7. FLAIR-HASTE sequence in differential diagnosis of focal hepatic lesions

    International Nuclear Information System (INIS)

    Kim, Yong Jae; Kim, Tae Kyoung; Bae, In Young; Kim, Pyo Nyun; Ha, Hyun Kwon; Kim, Ah Young; Lee, Moon Gyu

    2001-01-01

    To assess the feasibility of using the FLAIR (fluid-attenuated inversion recovery)-HASTE (half-fourier acquisition single-shot turbo spin-echo) sequence for the differential diagnosis of focal hepatic lesions. During a 12-month period, 80 patients with 127 focal hepatic lesions [hemangiomas (n=60), hepatocellular carcinomas (HCC) (n=27), cysts (n=25), and metastases (n=15) underwent MR imaging using a 1.5-T scanner. Verification of the diagnosis was based on the findings of pathology (n=11), of angiography and clinical investigation (n=17), or of dynamic contrast-enhanced MR imaging (n=99). MR sequences included T2-weighted HASTE (TE, 134 ms ; echo space, 4.4 ms), FLAIR-HASTE (TE, 64 ms ; echo space, 4.4 ms ; inversion time, 2000 ms ; number of slices, 5-9 ; acquisition time, 13-20 s), and dynamic gadolinium-enhanced T1-weighted FLASH (TR, 131 ms ; TE, 4 ms). FLAIR-HASTE imaging was of any focal lesions seen on T2-weighted HASTE images was performed in the liver area, and their signal intensity was classified in one of five ways : very high (higher than the spleen), moderately high (similar to the spleen), slightly high (higher than the liver and lower than the spleen), intermediate (similar to the liver), or low (lower than the liver). The signal intensity of the 25 cysts, as determined by FLAIR-HASTE, was low in 21 cases (84%), intermediate in three (12%), and very high in one (4%), which was diagnosed as a complicated cyst in which ultrasound revealed internal septa. At FLAIR-HASTE, all 60 hemangiomas showed either very high (n=50, 83%) or moderately high (n=10, 17%) signal intensity, while that of 42 hepatic malignant tumors was very high in 14 cases (33%), moderately high in 8 (19%), slightly high in 18 (43%), intermediate in one (2.5%), and low in one (2.5%). FLAIR-HASTE showed that the signal intensity of the majority of hepatic cysts was low, while that of most hemangiomas and solid liver tumors was high. For the differential diagnosis of cystic and

  8. Fast FLAIR MR imaging finidngs of cerebral infarction : comparison with T2-weighted spin echo imaging

    International Nuclear Information System (INIS)

    Kong, Keun Young; Choi, Woo Suk; Kim, Eui Jong

    1997-01-01

    To evaluate the utility of FLAIR(Fluid Attenuated Inversion Recovery) MR imaging in cerebral infarction by comparing its results with those of T2-weighted spin-echo imaging. We retrospectively evaluated fast FLAIR images and conventional spin echo images of 82 patients (47 men and 20 women ; median age 60.9 years) with cerebral infarction. MR imaging used a 1.5T MR unit with conventional T2(TR 3900, TE 90) and fast FLAIR sequence (TR 8000, TE 105, TI 2400). We analysed the size of the main lesion and number of lesions, and discrimination between old and new lesions and between small infarction and perivascular space. When T2-weighted and FLAIR imaging were compared, the latter showed that the main lesion was larger in 38 cases (46%), similar in 38 (46%), and smaller in six (7%). The number of lesions was greater in 23 cases(28%), similar in 52 (63%), and fewer in seven (9%). FLAIR images discriminated between old and new lesions in 31 cases ; perivascular space and small infarotion were differentiated in eight cases, and CSF inflowing artifact was observed in 66 (80%). In the diagnosis of cerebral infaretion, fast FLAIR provides images that are equal or superior to T2-weighted images. The fast FLAIR sequence may therefore be used as a part of routine MR brain study in the diagnosis of cerebral infarction

  9. Revisiting the relationship of three-dimensional fluid attenuation inversion recovery imaging and hearing outcomes in adults with idiopathic unilateral sudden sensorineural hearing loss

    Energy Technology Data Exchange (ETDEWEB)

    Liao, Wen-Huei [School of Medicine, National Yang Ming University, Taipei, 11221, Taiwan (China); Department of Otolaryngology, Taipei Veterans General Hospital, Taipei, 11217, Taiwan (China); Wu, Hsiu-Mei [School of Medicine, National Yang Ming University, Taipei, 11221, Taiwan (China); Department of Radiology, Taipei Veterans General Hospital, Taipei, 11217, Taiwan (China); Wu, Hung-Yi [Department of Radiology, Taipei Veterans General Hospital, Taipei, 11217, Taiwan (China); Tu, Tzong-Yang; Shiao, An-Suey [School of Medicine, National Yang Ming University, Taipei, 11221, Taiwan (China); Department of Otolaryngology, Taipei Veterans General Hospital, Taipei, 11217, Taiwan (China); Castillo, Mauricio [Department of Radiology, University of North Carolina, Chapel Hill, NC, 27599-7510 (United States); Hung, Sheng-Che, E-mail: hsz829@gmail.com [School of Medicine, National Yang Ming University, Taipei, 11221, Taiwan (China); Department of Radiology, Taipei Veterans General Hospital, Taipei, 11217, Taiwan (China); Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, Taipei, 11221, Taiwan (China)

    2016-12-15

    Background and purpose: Three-dimensional fluid attenuation inversion recovery (3D FLAIR) may demonstrate high signal in the inner ears of patients with idiopathic sudden sensorineural hearing loss (ISSNHL), but the correlations of this finding with outcomes are still controversial. Here we compared 4 3D MRI sequences with the outcomes of patients with ISSNHL. Materials and methods: 77 adult patients with ISSNHL underwent MRI with pre contrast FLAIR, fast imaging employing steady-state acquisition images (FIESTA-C), post contrast T1WI and post contrast FLAIR. The extent and degree of high signal in both cochleas were evaluated in all patients, and asymmetry ratios between the affected ears and the normal ones were calculated. The relationships among MRI findings, including extent and asymmetry of abnormal cochlear high signals, degree of FLAIR enhancement, and clinical information, including age, vestibular symptoms, baseline hearing loss, and final hearing outcomes were analyzed. Results: 54 patients (28 men; age, 52.1 ± 15.5 years) were included in our study. Asymmetric cochlear signal intensities were more frequently observed in pre contrast and post contrast FLAIR (79.6% and 68.5%) than in FIESTA-C (61.1%) and T1WI (51.9%) (p < 0.001). Age, baseline hearing loss, extent of high signal and asymmetry ratios of pre contrast and post contrast FLAIR were all correlated with final hearing outcomes. In multivariate analysis, age and the extent of high signals were the most significant predictors of final hearing outcomes. Conclusion: 3D FLAIR provides a higher sensitivity in detecting the asymmetric cochlear signal abnormality. The more asymmetric FLAIR signals and presence of high signals beyond cochlea indicated a poorer prognosis.

  10. FLAIR lesion segmentation: Application in patients with brain tumors and acute ischemic stroke

    International Nuclear Information System (INIS)

    Artzi, Moran; Aizenstein, Orna; Jonas-Kimchi, Tali; Myers, Vicki; Hallevi, Hen; Ben Bashat, Dafna

    2013-01-01

    Background: Lesion size in fluid attenuation inversion recovery (FLAIR) images is an important clinical parameter for patient assessment and follow-up. Although manual delineation of lesion areas considered as ground truth, it is time-consuming, highly user-dependent and difficult to perform in areas of indistinct borders. In this study, an automatic methodology for FLAIR lesion segmentation is proposed, and its application in patients with brain tumors undergoing therapy; and in patients following stroke is demonstrated. Materials and methods: FLAIR lesion segmentation was performed in 57 magnetic resonance imaging (MRI) data sets obtained from 44 patients: 28 patients with primary brain tumors; 5 patients with recurrent-progressive glioblastoma (rGB) who were scanned longitudinally during anti-angiogenic therapy (18 MRI scans); and 11 patients following ischemic stroke. Results: FLAIR lesion segmentation was obtained in all patients. When compared to manual delineation, a high visual similarity was observed, with an absolute relative volume difference of 16.80% and 20.96% and a volumetric overlap error of 24.87% and 27.50% obtained for two raters: accepted values for automatic methods. Quantitative measurements of the segmented lesion volumes were in line with qualitative radiological assessment in four patients who received anti-anogiogenic drugs. In stroke patients the proposed methodology enabled identification of the ischemic lesion and differentiation from other FLAIR hyperintense areas, such as pre-existing disease. Conclusion: This study proposed a replicable methodology for FLAIR lesion detection and quantification and for discrimination between lesion of interest and pre-existing disease. Results from this study show the wide clinical applications of this methodology in research and clinical practice

  11. FLAIR lesion segmentation: Application in patients with brain tumors and acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Artzi, Moran, E-mail: artzimy@gmail.com [The Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv Sourasky Medical Center, Tel Aviv (Israel); Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel); Aizenstein, Orna, E-mail: ornaaize@gmail.com [The Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv Sourasky Medical Center, Tel Aviv (Israel); Jonas-Kimchi, Tali, E-mail: talijk@tlvmc.gov.il [Radiology Department, Tel Aviv Sourasky Medical Center, Tel Aviv (Israel); Myers, Vicki, E-mail: vicki_myers@hotmail.com [The Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv Sourasky Medical Center, Tel Aviv (Israel); Hallevi, Hen, E-mail: hen.hallevi@gmail.com [Neurology Department, Tel Aviv Sourasky Medical Center, Tel Aviv (Israel); Ben Bashat, Dafna, E-mail: dafnab@tlvmc.gov.il [The Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv Sourasky Medical Center, Tel Aviv (Israel); Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel)

    2013-09-15

    Background: Lesion size in fluid attenuation inversion recovery (FLAIR) images is an important clinical parameter for patient assessment and follow-up. Although manual delineation of lesion areas considered as ground truth, it is time-consuming, highly user-dependent and difficult to perform in areas of indistinct borders. In this study, an automatic methodology for FLAIR lesion segmentation is proposed, and its application in patients with brain tumors undergoing therapy; and in patients following stroke is demonstrated. Materials and methods: FLAIR lesion segmentation was performed in 57 magnetic resonance imaging (MRI) data sets obtained from 44 patients: 28 patients with primary brain tumors; 5 patients with recurrent-progressive glioblastoma (rGB) who were scanned longitudinally during anti-angiogenic therapy (18 MRI scans); and 11 patients following ischemic stroke. Results: FLAIR lesion segmentation was obtained in all patients. When compared to manual delineation, a high visual similarity was observed, with an absolute relative volume difference of 16.80% and 20.96% and a volumetric overlap error of 24.87% and 27.50% obtained for two raters: accepted values for automatic methods. Quantitative measurements of the segmented lesion volumes were in line with qualitative radiological assessment in four patients who received anti-anogiogenic drugs. In stroke patients the proposed methodology enabled identification of the ischemic lesion and differentiation from other FLAIR hyperintense areas, such as pre-existing disease. Conclusion: This study proposed a replicable methodology for FLAIR lesion detection and quantification and for discrimination between lesion of interest and pre-existing disease. Results from this study show the wide clinical applications of this methodology in research and clinical practice.

  12. Maturation of the limbic system revealed by MR FLAIR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Jacques F.; Vergesslich, Klara [University Children' s Hospital UKBB, Department of Paediatric Radiology, Basel (Switzerland)

    2007-04-15

    Cortical signal intensity (SI) of the limbic system in adults is known to be higher than in neocortical structures, but time-related changes in SI during childhood have not been described. To detect maturation-related SI changes within the limbic system using a fluid-attenuated inversion recovery (FLAIR) MR sequence. Twenty children (10 boys, 10 girls; age 3.5-18 years, mean 11.2 years) with no neurological abnormality and normal MR imaging examination were retrospectively selected. On two coronal FLAIR slices, ten regions of interest (ROI) with a constant area of 10 mm{sup 2} were manually placed in the archeocortex (hippocampus), periarcheocortex (parahippocampal gyrus, subcallosal area, cingulate gyrus) and in the neocortex at the level of the superior frontal gyrus on both sides. Significant SI gradients were observed with a higher intensity in the archeocortex, intermediate intensity in the periarcheocortex and low intensity in the neocortex. Significant higher SI values in hippocampal and parahippocampal structures were detected in children up to 10 years of age. These differences mainly reflected differences in cortical structure and myelination state. Archeocortical structures especially showed significant age-related intensity progression suggesting ongoing organization and/or myelination until early adolescence. (orig.)

  13. Maturation of the limbic system revealed by MR FLAIR imaging

    International Nuclear Information System (INIS)

    Schneider, Jacques F.; Vergesslich, Klara

    2007-01-01

    Cortical signal intensity (SI) of the limbic system in adults is known to be higher than in neocortical structures, but time-related changes in SI during childhood have not been described. To detect maturation-related SI changes within the limbic system using a fluid-attenuated inversion recovery (FLAIR) MR sequence. Twenty children (10 boys, 10 girls; age 3.5-18 years, mean 11.2 years) with no neurological abnormality and normal MR imaging examination were retrospectively selected. On two coronal FLAIR slices, ten regions of interest (ROI) with a constant area of 10 mm 2 were manually placed in the archeocortex (hippocampus), periarcheocortex (parahippocampal gyrus, subcallosal area, cingulate gyrus) and in the neocortex at the level of the superior frontal gyrus on both sides. Significant SI gradients were observed with a higher intensity in the archeocortex, intermediate intensity in the periarcheocortex and low intensity in the neocortex. Significant higher SI values in hippocampal and parahippocampal structures were detected in children up to 10 years of age. These differences mainly reflected differences in cortical structure and myelination state. Archeocortical structures especially showed significant age-related intensity progression suggesting ongoing organization and/or myelination until early adolescence. (orig.)

  14. FLAIR imaging in the follow-up of low-grade gliomas: time to dispense with the dual-echo?

    Energy Technology Data Exchange (ETDEWEB)

    Bynevelt, M.; Britton, J.; Seymour, H.; MacSweeney, E.; Sandhu, K. [Atkinson Morley' s Hospital, London (United Kingdom). Dept. of Neuroradiology; Thomas, N. [Dept. of Neurosurgery, Atkinson Morley' s Hospital, London (United Kingdom)

    2001-02-01

    Fluid-attenuated inversion-recovery (FLAIR) imaging has established its utility in neuroimaging. We propose this imaging sequence as a replacement for proton density (PD) and T2-weighted spin-echo sequences in the follow-up of low-grade glioma. 26 MRI examinations of 18 patients with such tumours were reviewed by three neuroradiologists and a neurosurgeon. FLAIR was found to be superior for appreciation of the lesion (91 % of studies) and for demonstration of its margin (92 %). FLAIR was also better at showing different tumour components, particularly in regions difficult to demonstrate in some planes, such as the vertex in axial imaging. The sequence also defines the postoperative cavity, shows the least amount of susceptibility effect associated with surgical clips, and demonstrates local spread (to white matter tracts, subependymal and capsular) more distinctly. We conclude that FLAIR can replace PD and T2-weighted spin-echo imaging in radiological follow-up of low-grade glioma. (orig.)

  15. MRI in neuro-Behcet's syndrome: comparison of conventional spin-echo and FLAIR pulse sequences

    International Nuclear Information System (INIS)

    Jaeger, H.R.; Albrecht, T.; Curati-Alasonatti, W.L.; Williams, E.J.; Haskard, D.O.

    1999-01-01

    We compared the sensitivity of a fluid-attenuated inversion-recovery (FLAIR) sequence with that of a conventional dual-echo spin-echo (SE) sequence to brain lesions in 20 patients with Behcet's syndrome. They underwent 25 MRI examinations. The images were independently analysed for the number, type and anatomical location of lesions shown. There were 18 abnormal studies (13 initial and 5 follow-up). The FLAIR sequence detected significantly more lesions than the SE TE 80 (P < 0.05) and SE TE 20 (P < 0.01) sequences. It was particularly useful for demonstrating lesions in the juxtacortical white matter, which accounted for over half the lesions detected on the FLAIR images. Of patients presenting with nonspecific symptoms such as headache, seven had normal and five had abnormal studies. All patients presenting with focal neurological signs had abnormal imaging. We found supratentorial and, in particular, juxtacortical lesions to be more frequent than previously described. (orig.)

  16. Improve Image Quality of Transversal Relaxation Time PROPELLER and FLAIR on Magnetic Resonance Imaging

    Science.gov (United States)

    Rauf, N.; Alam, D. Y.; Jamaluddin, M.; Samad, B. A.

    2018-03-01

    The Magnetic Resonance Imaging (MRI) is a medical imaging technique that uses the interaction between the magnetic field and the nuclear spins. MRI can be used to show disparity of pathology by transversal relaxation time (T2) weighted images. Some techniques for producing T2-weighted images are Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction (PROPELLER) and Fluid Attenuated Inversion Recovery (FLAIR). A comparison of T2 PROPELLER and T2 FLAIR parameters in MRI image has been conducted. And improve Image Quality the image by using RadiAnt DICOM Viewer and ENVI software with method of image segmentation and Region of Interest (ROI). Brain images were randomly selected. The result of research showed that Time Repetition (TR) and Time Echo (TE) values in all types of images were not influenced by age. T2 FLAIR images had longer TR value (9000 ms), meanwhile T2 PROPELLER images had longer TE value (100.75 - 102.1 ms). Furthermore, areas with low and medium signal intensity appeared clearer by using T2 PROPELLER images (average coefficients of variation for low and medium signal intensity were 0.0431 and 0.0705, respectively). As for areas with high signal intensity appeared clearer by using T2 FLAIR images (average coefficient of variation was 0.0637).

  17. Comparison between FLAIR images and T2-weighted fast spin-echo images of cerebral territory and lacunar infarction

    International Nuclear Information System (INIS)

    Paeng, Mi Hye; Choi, Hye-Young; Lim, Soo Mee; Lee, Jung Sik

    2003-01-01

    To assess the significance of fluid-attenuated inversion recovery (FLAIR) magnetic resonance (MR) imaging in the diagnosis of intracranial infarctions and to find out differential points between central lacunar infarctions and perivascular spaces. We consecutively selected 25 cases of territorial infarction in 20 patients, 37 cases of central infarction in 40 patients, and 30 patients with perivascular space. Signal intensity and lesion conspicuity were analyzed and compared between FLAIR and FSE T2-weighted images, and differences in signal intensity between central infarction and perivascular spaces were determined. Lesion conspicuity for FLAIR was better than for T2-weighted images in 12 and 15, worse in 4 and 24, and similar in 9 and 16 of territorial and central infarctions, respectively. In nine cases of territorial and one case of central infarction, there was associated hemorrhage. At FLAIR imaging, perivascular spaces showed a fine round low signal without a peripheral high signal rim in 17 patients but no demonstrable signals in 15. Differential diagnosis of perivascular spaces and central infarction was thus not difficult. FLAIR MRI was useful in the diagnosis of infarctions and in differentiating between central small lacular infarctions and perivascular spaces

  18. FLAIR vascular hyperintensities predict early ischemic recurrence in TIA.

    Science.gov (United States)

    Nam, Ki-Woong; Kim, Chi Kyung; Kim, Tae Jung; Oh, Kyungmi; Han, Moon-Ku; Ko, Sang-Bae; Yoon, Byung-Woo

    2018-02-27

    To evaluate the relationship between fluid-attenuated inversion recovery (FLAIR) vascular hyperintensity (FVH) and early ischemic lesion recurrence (follow-up diffusion-weighted imaging [FU-DWI] [+]) in patients with lesion-negative TIA. We recruited consecutive patients with lesion-negative TIA within 24 hours of symptom onset, who underwent follow-up MRI during the acute period. FVH was defined as a focal or serpentine high signal intensity on FLAIR images. Other potential confounders were adjusted to evaluate the relationship between FVH and FU-DWI (+). Furthermore, to compare clinical outcomes between the FU-DWI (+) and FU-DWI (-) groups, we assessed 1-year recurrent ischemic stroke or TIA. Among 392 patients with lesion-negative TIA, 82 patients had FU-DWI (+) on the follow-up MRI. In the multivariate analysis, FVH remained an independent predictor of FU-DWI (+) (adjusted odds ratio [aOR] = 4.77, 95% confidence interval [CI] 2.45-9.29, p TIA. As FU-DWI (+) frequently occurs during the acute period and has a subsequent worse outcome after discharge, additional radiologic or clinical markers for it are necessary. © 2018 American Academy of Neurology.

  19. Detection of aneurysmal subarachnoid hemorrhage 3 months after initial bleeding: evaluation of T2* and FLAIR MR sequences at 3 T in comparison with initial non-enhanced CT as a gold standard.

    Science.gov (United States)

    Mulé, Sébastien; Soize, Sébastien; Benaissa, Azzedine; Portefaix, Christophe; Pierot, Laurent

    2016-08-01

    To investigate the ability of T2* and fluid-attenuated inversion recovery (FLAIR) MR sequences to detect hemosiderin deposition 3 months after aneurysmal subarachnoid hemorrhage (SAH) in comparison with early non-enhanced CT (NECT) as a gold standard. From September 2008 through May 2013, patients with aneurysmal SAH were included if a NECT less than 24 h after the onset of symptoms showed a SAH, and MRI, including T2* and FLAIR sequences, was performed 3 months later. All aneurysms were treated endovascularly. NECT and MR sequences were blindly analyzed for the presence of SAH (NECT) or hemosiderin deposition (MRI). When positive, details of the spatial distribution of SAH or hemosiderin deposits were noted. Sensitivities were calculated for each patient. Sensitivities, specificities, and positive predictive values (PPVs) were calculated for each location. Forty-nine patients (mean age 52.9 years) were included. Bleeding-related patterns were identified in 43 patients (87.8%) on T2* and 10 patients (20.4%) on FLAIR. T2* was highly predictive of the location of the initial hemorrhage, especially in the Sylvian cisterns (PPVs 95% and 100%) and the anterior interhemispheric fissure (PPV 90%). The T2* sequence can detect and localize a previous SAH a few months after aneurysmal bleeding. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. 3D shape recovery from image focus using Gabor features

    Science.gov (United States)

    Mahmood, Fahad; Mahmood, Jawad; Zeb, Ayesha; Iqbal, Javaid

    2018-04-01

    Recovering an accurate and precise depth map from a set of acquired 2-D image dataset of the target object each having different focus information is an ultimate goal of 3-D shape recovery. Focus measure algorithm plays an important role in this architecture as it converts the corresponding color value information into focus information which will be then utilized for recovering depth map. This article introduces Gabor features as focus measure approach for recovering depth map from a set of 2-D images. Frequency and orientation representation of Gabor filter features is similar to human visual system and normally applied for texture representation. Due to its little computational complexity, sharp focus measure curve, robust to random noise sources and accuracy, it is considered as superior alternative to most of recently proposed 3-D shape recovery approaches. This algorithm is deeply investigated on real image sequences and synthetic image dataset. The efficiency of the proposed scheme is also compared with the state of art 3-D shape recovery approaches. Finally, by means of two global statistical measures, root mean square error and correlation, we claim that this approach, in spite of simplicity, generates accurate results.

  1. Diagnostic value of three-dimensional fluid-attenuated inversion recovery MR imaging after intratympanic administration of contrast media in Meniere's disease

    International Nuclear Information System (INIS)

    Shi Honglu; Zhang Daogong; Wang Guangbin; Fan Zhaomin; Bai Xue; Guo Lijun; Man Xiaoni

    2012-01-01

    Objective: After intratympanic gadolinium administration through the tympanic membrane, three-dimensional fluid-attenuated inversion recovery magnetic resonance imaging (3D-FLAIR MRI) was performed to evaluate endolymphatic visualization and its diagnostic value in Meniere's disease. Methods: Twenty-four hours after intratympanic gadolinium administration through the tympanic membrane, 19 patients with unilateral Meniere's disease diagnosed clinically underwent 3D-FLAIR and 3D-Balance-FFE imaging at 3.0 T MR scanner. The enhanced imaging of perilymphatic space in bilateral cochlea, vestibular and (or) canal were observed. Scala tympani and scala vestibule of bilateral cochlear basal turn were scored respectively. The enhanced range of bilateral vestibule and the signal intensity ratio (SIR) between the vestibule and the brain stem were measured. Wilcoxon tests and paired t tests were used. Results: The gadolinium appeared in almost all parts of the perilymph in cochlea,vestibular and (or) canal, so the endolymphatic space was clearly visualized on 3D-FLAIR imaging. The score of scala vestibuli between the affected side (3 cases scored 2, 9 cases scored 1, 7 cases scored 0) and the healthy side (15 cases scored 2, 2 cases scored 1, 2 cases scored 0) were significantly different (U=3.090, P<0.05). The area of enhanced vestibular were (5.77 ± 2.33) mm 2 and (8.11 ± 3.32) mm 2 for the affected side and the healthy side, which were significantly different (U=3.090, P<0.05 and t=2.638, P<0.05). Conclusions: According to 3D-Balance-FFE MRI and the enhancement of perilymphatic space, 3D-FLAIR MRI with intratympanic gadolinium injection through the tympanic membrane can be used to show the border between the perilymph and the endolymph and confirm endolymphatic hydrops, thus providing radiographic evidence for the diagnosis of Meniere's disease. (authors)

  2. Microbial Enhanced Oil Recovery: 3D Simulation with Gravity Effects

    DEFF Research Database (Denmark)

    Nielsen, Sidsel Marie; Jessen, K.; Shapiro, Alexander

    2010-01-01

    Microbial enhanced oil recovery (MEOR) utilizes the activity of microorganisms, where microorganisms simultaneously grow in a reservoir and convert substrate into recovery enhancing products (usually, surfactants). In order to predict the performance of a MEOR process, a simulation tool is required...... using an operator splitting technique. To the best of our knowledge, this has resulted in the first full 3D MEOR streamline simulator. For verification purposes, we compare results from our streamline MEOR simulator to those of a conventional finite difference approach for 1D and 2D displacement...

  3. Fluid-attenuated inversion recovery vascular hyperintensities in predicting cerebral hyperperfusion after intracranial arterial stenting

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Chih-Cheng; Chen, David Yen-Ting; Tseng, Ying-Chi; Lee, Kun-Yu; Chiang, Chen-Hua; Chen, Chi-Jen [Taipei Medical University, Department of Radiology, Shuang-Ho Hospital, New Taipei City (China); Taipei Medical University, School of Medicine, College of Medicine, Taipei (China); Yan, Feng-Xian [Taipei Medical University, Department of Radiology, Shuang-Ho Hospital, New Taipei City (China)

    2017-08-15

    No reliable imaging sign predicting cerebral hyperperfusion after intracranial arterial stenting (IAS) had been described in the literature. This study evaluated the effect of fluid-attenuated inversion recovery vascular hyperintensities (FVHs), also called hyperintense vessel sign on T2-weighted fluid-attenuated inversion recovery (T2-FLAIR) MR images, in predicting significant increase in cerebral blood flow (CBF) defined by arterial spin labeling (ASL) after IAS. We reviewed ASL CBF images and T2-FLAIR MR images before (D0), 1 day after (D1), and 3 days after (D3) IAS of 16 patients. T1-weighted MR images were used as cerebral maps for calculating CBF. The changes in CBF values after IAS were calculated in and compared among stenting and nonstenting vascular territories. An increase more than 50% of CBF was considered as hyperperfusion. The effect of FVHs in predicting hyperperfusion was calculated. The D1 CBF value was significantly higher than the D0 CBF value in stenting vascular, contralateral anterior cerebral artery, contralateral middle cerebral artery, and contralateral posterior cerebral artery (PCA) territories (all P <.05). The D1 and D3 CBF values were significantly higher than the D0 CBF value in overall vascular (P <.001), overall nonstenting vascular (P <.001), and ipsilateral PCA (P <.05) territories. The rate of more than 50% increases in CBF was significantly higher in patients who exhibited asymmetric FVHs than in those who did not exhibit these findings. FVHs could be a critical predictor of a significant increase in CBF after IAS. (orig.)

  4. Fluid-attenuated inversion recovery vascular hyperintensities in predicting cerebral hyperperfusion after intracranial arterial stenting

    International Nuclear Information System (INIS)

    Wan, Chih-Cheng; Chen, David Yen-Ting; Tseng, Ying-Chi; Lee, Kun-Yu; Chiang, Chen-Hua; Chen, Chi-Jen; Yan, Feng-Xian

    2017-01-01

    No reliable imaging sign predicting cerebral hyperperfusion after intracranial arterial stenting (IAS) had been described in the literature. This study evaluated the effect of fluid-attenuated inversion recovery vascular hyperintensities (FVHs), also called hyperintense vessel sign on T2-weighted fluid-attenuated inversion recovery (T2-FLAIR) MR images, in predicting significant increase in cerebral blood flow (CBF) defined by arterial spin labeling (ASL) after IAS. We reviewed ASL CBF images and T2-FLAIR MR images before (D0), 1 day after (D1), and 3 days after (D3) IAS of 16 patients. T1-weighted MR images were used as cerebral maps for calculating CBF. The changes in CBF values after IAS were calculated in and compared among stenting and nonstenting vascular territories. An increase more than 50% of CBF was considered as hyperperfusion. The effect of FVHs in predicting hyperperfusion was calculated. The D1 CBF value was significantly higher than the D0 CBF value in stenting vascular, contralateral anterior cerebral artery, contralateral middle cerebral artery, and contralateral posterior cerebral artery (PCA) territories (all P <.05). The D1 and D3 CBF values were significantly higher than the D0 CBF value in overall vascular (P <.001), overall nonstenting vascular (P <.001), and ipsilateral PCA (P <.05) territories. The rate of more than 50% increases in CBF was significantly higher in patients who exhibited asymmetric FVHs than in those who did not exhibit these findings. FVHs could be a critical predictor of a significant increase in CBF after IAS. (orig.)

  5. Computer aided detection of tumor and edema in brain FLAIR magnetic resonance image using ANN

    Science.gov (United States)

    Pradhan, Nandita; Sinha, A. K.

    2008-03-01

    This paper presents an efficient region based segmentation technique for detecting pathological tissues (Tumor & Edema) of brain using fluid attenuated inversion recovery (FLAIR) magnetic resonance (MR) images. This work segments FLAIR brain images for normal and pathological tissues based on statistical features and wavelet transform coefficients using k-means algorithm. The image is divided into small blocks of 4×4 pixels. The k-means algorithm is used to cluster the image based on the feature vectors of blocks forming different classes representing different regions in the whole image. With the knowledge of the feature vectors of different segmented regions, supervised technique is used to train Artificial Neural Network using fuzzy back propagation algorithm (FBPA). Segmentation for detecting healthy tissues and tumors has been reported by several researchers by using conventional MRI sequences like T1, T2 and PD weighted sequences. This work successfully presents segmentation of healthy and pathological tissues (both Tumors and Edema) using FLAIR images. At the end pseudo coloring of segmented and classified regions are done for better human visualization.

  6. Clinical-Radiological Parameters Improve the Prediction of the Thrombolysis Time Window by Both MRI Signal Intensities and DWI-FLAIR Mismatch.

    Science.gov (United States)

    Madai, Vince Istvan; Wood, Carla N; Galinovic, Ivana; Grittner, Ulrike; Piper, Sophie K; Revankar, Gajanan S; Martin, Steve Z; Zaro-Weber, Olivier; Moeller-Hartmann, Walter; von Samson-Himmelstjerna, Federico C; Heiss, Wolf-Dieter; Ebinger, Martin; Fiebach, Jochen B; Sobesky, Jan

    2016-01-01

    With regard to acute stroke, patients with unknown time from stroke onset are not eligible for thrombolysis. Quantitative diffusion weighted imaging (DWI) and fluid attenuated inversion recovery (FLAIR) MRI relative signal intensity (rSI) biomarkers have been introduced to predict eligibility for thrombolysis, but have shown heterogeneous results in the past. In the present work, we investigated whether the inclusion of easily obtainable clinical-radiological parameters would improve the prediction of the thrombolysis time window by rSIs and compared their performance to the visual DWI-FLAIR mismatch. In a retrospective study, patients from 2 centers with proven stroke with onset value/mean value of the unaffected hemisphere). Additionally, the visual DWI-FLAIR mismatch was evaluated. Prediction of the thrombolysis time window was evaluated by the area-under-the-curve (AUC) derived from receiver operating characteristic (ROC) curve analysis. Factors such as the association of age, National Institutes of Health Stroke Scale, MRI field strength, lesion size, vessel occlusion and Wahlund-Score with rSI were investigated and the models were adjusted and stratified accordingly. In 82 patients, the unadjusted rSI measures DWI-mean and -SD showed the highest AUCs (AUC 0.86-0.87). Adjustment for clinical-radiological covariates significantly improved the performance of FLAIR-mean (0.91) and DWI-SD (0.91). The best prediction results based on the AUC were found for the final stratified and adjusted models of DWI-SD (0.94) and FLAIR-mean (0.96) and a multivariable DWI-FLAIR model (0.95). The adjusted visual DWI-FLAIR mismatch did not perform in a significantly worse manner (0.89). ADC-rSIs showed fair performance in all models. Quantitative DWI and FLAIR MRI biomarkers as well as the visual DWI-FLAIR mismatch provide excellent prediction of eligibility for thrombolysis in acute stroke, when easily obtainable clinical-radiological parameters are included in the prediction

  7. 3D shape recovery from image focus using gray level co-occurrence matrix

    Science.gov (United States)

    Mahmood, Fahad; Munir, Umair; Mehmood, Fahad; Iqbal, Javaid

    2018-04-01

    Recovering a precise and accurate 3-D shape of the target object utilizing robust 3-D shape recovery algorithm is an ultimate objective of computer vision community. Focus measure algorithm plays an important role in this architecture which convert the color values of each pixel of the acquired 2-D image dataset into corresponding focus values. After convolving the focus measure filter with the input 2-D image dataset, a 3-D shape recovery approach is applied which will recover the depth map. In this document, we are concerned with proposing Gray Level Co-occurrence Matrix along with its statistical features for computing the focus information of the image dataset. The Gray Level Co-occurrence Matrix quantifies the texture present in the image using statistical features and then applies joint probability distributive function of the gray level pairs of the input image. Finally, we quantify the focus value of the input image using Gaussian Mixture Model. Due to its little computational complexity, sharp focus measure curve, robust to random noise sources and accuracy, it is considered as superior alternative to most of recently proposed 3-D shape recovery approaches. This algorithm is deeply investigated on real image sequences and synthetic image dataset. The efficiency of the proposed scheme is also compared with the state of art 3-D shape recovery approaches. Finally, by means of two global statistical measures, root mean square error and correlation, we claim that this approach -in spite of simplicity generates accurate results.

  8. Ivy signs on FLAIR images before and after STA-MCA anastomosis in patients with Moyamoya disease

    Energy Technology Data Exchange (ETDEWEB)

    Ideguchi, Reiko; Enokizono, Mikako; Uetani, Masataka (Dept. of Radiological Sciences, Nagasaki Univ. Graduate School of Biomedical Sciences, Nagasaki (Japan)), e-mail: qqtt37gd9@forest.ocn.ne.jp; Morikawa, Minoru (Dept. of Radiology, Nagasaki Univ. School of Medicine, Nagasaki (Japan)); Ogawa, Yoji (Dept. of Radiology, Hanwa Daini Senboku Hospital, Osaka (Japan)); Nagata, Izumi (Dept. of Neurosurgery, Nagasaki Univ. School of Medicine, Nagasaki (Japan))

    2011-04-15

    Background: Leptomeningeal high signal intensity (ivy sign) on fluid-attenuated inversion-recovery (FLAIR) MR imaging is one of the features of Moyamoya disease. However, the correlation between ivy sign and cerebral perfusion status has not been fully evaluated. Purpose: To characterize ivy sign on FLAIR images in Moyamoya disease and compare this finding with hemodynamic alterations on perfusion single-photon emission CT (SPECT) obtained before and after bypass surgery. Material and Methods: Sixteen patients with angiographically confirmed Moyamoya disease who underwent superficial temporal artery-middle cerebral artery (STA-MCA) anastomosis were included in the study. The presence of ivy sign on FLAIR images was classified as 'negative', 'minimal' and 'positive'. We evaluated the relationship between ivy sign and findings of SPECT, including cerebral vascular reserve (CVR) before and after surgery. Results: Minimal or positive ivy sign was seen in 13 (81%) of 16 patients, and 21 (66%) of 32 hemispheres. CVR in the areas with positive or minimal ivy sign was lower than that in the areas with negative ivy sign. After STA-MCA anastomosis, ivy sign disappeared or decreased in all 21 hemispheres demonstrating ivy sign. SPECT demonstrated apparent hemodynamic improvement in areas demonstrating disappearance or decrease of ivy sign. Conclusion: Ivy sign on FLAIR image is seen in areas with decreased cerebral perfusion. The sign is useful for non-invasive assessment of cerebral hemodynamic status before and after surgery

  9. MRI in seven cases of tacrolimus (FK-506) encephalopathy: utility of FLAIR and diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Furukawa, M. [Dept. of Radiology, Yamaguchi University School of Medicine, Ube (Japan); Dept. of Radiology, Hokkaido University School of Medicine, Sapporo (Japan); Terae, S.; Chu, B.C.; Kaneko, K.; Kamada, H.; Miyasaka, K. [Dept. of Radiology, Hokkaido University School of Medicine, Sapporo (Japan)

    2001-08-01

    We assessed the utility of fluid-attenuated inversion-recovery (FLAIR) and diffusion-weighted (DWI) images in investigation of tacrolimus (FK-506) encephalopathy, and to see whether we could predict its cause from clinical and imaging data. In seven patients with presumed FK-506 toxicity the areas involved on MRI were similar to those in cyclosporin A (CsA) toxicity. The abnormal signal was most evident on FLAIR in all cases. In three of four patients who underwent DWI, no diffusion abnormalities were detected; in the remaining patient, increased diffusion was seen in the deep white matter bilaterally on the apparent diffusion coefficient map, consistent with the findings on T2-weighted spin-echo and FLAIR images. Five of the six patients for whom we had clinical data showed sudden changes in electrolyte or fluid equilibrium due to diarrhoea, a polyuria or oliguria one day before or on the day of onset of the central nervous system disturbances. We speculate that FK-506 encephalopathy is triggered by the disturbance of the electrolyte and/or fluid equilibrium, given a certain serum level of FK-506. (orig.)

  10. MRI in seven cases of tacrolimus (FK-506) encephalopathy: utility of FLAIR and diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Furukawa, M.; Terae, S.; Chu, B.C.; Kaneko, K.; Kamada, H.; Miyasaka, K.

    2001-01-01

    We assessed the utility of fluid-attenuated inversion-recovery (FLAIR) and diffusion-weighted (DWI) images in investigation of tacrolimus (FK-506) encephalopathy, and to see whether we could predict its cause from clinical and imaging data. In seven patients with presumed FK-506 toxicity the areas involved on MRI were similar to those in cyclosporin A (CsA) toxicity. The abnormal signal was most evident on FLAIR in all cases. In three of four patients who underwent DWI, no diffusion abnormalities were detected; in the remaining patient, increased diffusion was seen in the deep white matter bilaterally on the apparent diffusion coefficient map, consistent with the findings on T2-weighted spin-echo and FLAIR images. Five of the six patients for whom we had clinical data showed sudden changes in electrolyte or fluid equilibrium due to diarrhoea, a polyuria or oliguria one day before or on the day of onset of the central nervous system disturbances. We speculate that FK-506 encephalopathy is triggered by the disturbance of the electrolyte and/or fluid equilibrium, given a certain serum level of FK-506. (orig.)

  11. Low-energy antiprotons physics and the FLAIR facility

    International Nuclear Information System (INIS)

    Widmann, E

    2015-01-01

    FLAIR, the Facility for low-energy antiproton and ion research has been proposed in 2004 as an extension of the planned FAIR facility at Darmstadt, Germany. FLAIR was not included into the modularized start version of FAIR, but the recent installation of the CRYRING storage ring at GSI Darmstadt has opened new perspectives for physics with low-energy antiprotons at FAIR. (paper)

  12. A prospective comparison study of fast T1 weighted fluid attenuation inversion recovery and T1 weighted turbo spin echo sequence at 3 T in degenerative disease of the cervical spine.

    Science.gov (United States)

    Ganesan, K; Bydder, G M

    2014-09-01

    This study compared T1 fluid attenuation inversion recovery (FLAIR) and T1 turbo spin echo (TSE) sequences for evaluation of cervical spine degenerative disease at 3 T. 72 patients (44 males and 28 females; mean age of 39 years; age range, 27-75 years) with suspected cervical spine degenerative disease were prospectively evaluated. Sagittal images of the spine were obtained using T1 FLAIR and T1 TSE sequences. Two experienced neuroradiologists compared the sequences qualitatively and quantitatively. On qualitative evaluation, cerebrospinal fluid (CSF) nulling and contrast at cord-CSF, disc-CSF and disc-cord interfaces were significantly higher on fast T1 FLAIR images than on T1 TSE images (p degenerative disease, owing to higher cord-CSF, disc-cord and disc-CSF contrast. However, intrinsic cord contrast is low on T1 FLAIR images. T1 FLAIR is more promising and sensitive than T1 TSE for evaluation of degenerative spondyloarthropathy and may provide a foundation for development of MR protocols for early detection of degenerative and neoplastic diseases.

  13. Temporal pole signal abnormality on MR imaging in temporal lobe epilepsy with hippocampal sclerosis: a fluid-attenuated inversion-recovery study; Anormalidade de sinal na imagem por RM do polo temporal na epilepsia do lobo temporal com esclerose hipocampal: um estudo pela sequencia inversao recuperacao com supressao da agua livre (FLAIR)

    Energy Technology Data Exchange (ETDEWEB)

    Carrete Junior, Henrique; Abdala, Nitamar; Szjenfeld, Jacob; Nogueira, Roberto Gomes [Universidade Federal de Sao Paulo (UNIFESP-EPM), Sao Paulo, SP (Brazil). Dept. de Diagnostico por Imagem; Lin, Katia; Caboclo, Luis Otavio; Centeno, Ricardo Silva; Sakamoto, Americo Ceiki; Yacubian, Elza Marcia Targas [Universidade Federal de Sao Paulo (UNIFESP-EPM), Sao Paulo, SP (Brazil). Dept. de Neurologia e Neurocirurgia

    2007-09-15

    Objective: To determine the frequency and regional involvement of temporal pole signal abnormality (TPA) in patients with hippocampal sclerosis (HS) using fluid-attenuated inversion-recovery (FLAIR) MR imaging, and to correlate this feature with history. Method: Coronal FLAIR images of the temporal pole were assessed in 120 patients with HS and in 30 normal subjects, to evaluate gray-white matter demarcation. Results: Ninety (75%) of 120 patients had associated TPA. The HS side made difference regarding the presence of TPA, with a left side prevalence (p=0.04, {chi}{sup 2} test). The anteromedial zone of temporal pole was affected in 27 (30%) out of 90 patients. In 63 (70%) patients the lateral zone were also affected. Patients with TPA were younger at seizure onset (p=0.018), but without association with duration of epilepsy. Conclusion: Our FLAIR study show temporal pole signal abnormality in 3/4 of patients with HS, mainly seen on the anteromedial region, with a larger prevalence when the left hippocampus was involved. (author)

  14. 3D steady-state MR cisternography in CSF rhinorrhoea

    International Nuclear Information System (INIS)

    Jayakumar, P.N.; Kovoor, J.M.E.; Srikanth, S.G.; Praharaj, S.S.

    2001-01-01

    Purpose: To determine the utility of 3D steady-state MR cisternography in the demonstration and localisation of cerebrospinal fluid (CSF) leak in patients with clinically suspected CSF rhinorrhoea. Material and Methods: Six consecutive patients with clinically suspected CSF rhinorrhoea were examined with routine MR evaluation and MR cisternography (MRC). All MR examinations included fast spin-echo (SE) T1WI in axial and sagittal planes, fast SE T2WI in axial and coronal planes and fluid attenuated inversion recovery (FLAIR) images in the axial plane. 3D evaluation was done using the CISS technique with 0.7-mm thickness in the sagittal and coronal planes. The site and extent of the defect, and any brain herniation detected on MRC were correlated with surgical findings. Results: In the 6 patients who underwent surgical exploration and repair, intraoperative findings correlated with the defect revealed by MRC in all cases. Conclusion: In clinically suspected CSF rhinorrhoea, MRC is highly accurate in localising the site and extent of CSF fistula and may be used as the first investigation due to its efficacy and non-invasive nature

  15. Hyperintense vessels on FLAIR: A useful non-invasive method for assessing intracerebral collaterals

    International Nuclear Information System (INIS)

    Liu Wenhua; Xu Gelin; Yue Xuanye; Wang Xiaoliang; Ma Minmin; Zhang Renliang; Wang Handong; Zhou Changsheng; Liu Xinfeng

    2011-01-01

    Objective: This study was aimed to evaluate relationship between hyperintense vessels (HV) on fluid-attenuated inversion recovery (FLAIR) and artery steno-occlusion related intracerebral collaterals. Materials and methods: A total of 233 patients with 260 atherosclerotic lesions in the M1 segment of the middle cerebral artery (MCA) were examined with FLAIR and digital subtraction angiography (DSA). HV were graded as 0, 1, 2 and 3 by its distributions in the MCA territory. Grade 0 indicated no HV; Grade 1 indicated the HV limited in Sylvian fissure; Grade 2 indicated the HV limited in Sylvian fissure and the temporal-occipital junction; Grade 3 indicated the HV extended to frontal-parietal lobes. Collateral blood flows were classified by DSA results. The relationship between HV grades and patterns of collateral flows was analyzed. Results: HV were observed in 76 out of 260 hemispheres. For patients with Grade 1 HV, most of their collateral flows (80.8%) were antegrade; for patients with Grade 2, the retrograde leptomeningeal flows were commonly manifested as anterior cerebral artery to MCA (75%); for patients with Grade 3 HV, most of the retrograde leptomeningeal flows were manifested as posterior cerebral artery to MCA (81.8%). As the grade HV increased, the frequency of retrograde leptomeningeal collateral from ACA to MCA decreased (100% to 75% and to 18.2%), and increased (0% to 25% and to 81.8%) for the retrograde leptomeningeal collateral via PCA to MCA (P < 0.001). Conclusions: The HV could assess non-invasively intracerebral collaterals in patients with steno-occlusive lesions of M1 segment of MCA.

  16. Study of the fast inversion recovery pulse sequence. With reference to fast fluid attenuated inversion recovery and fast short TI inversion recovery pulse sequence

    International Nuclear Information System (INIS)

    Tsuchihashi, Toshio; Maki, Toshio; Suzuki, Takeshi

    1997-01-01

    The fast inversion recovery (fast IR) pulse sequence was evaluated. We compared the fast fluid attenuated inversion recovery (fast FLAIR) pulse sequence in which inversion time (TI) was established as equal to the water null point for the purpose of the water-suppressed T 2 -weighted image, with the fast short TI inversion recovery (fast STIR) pulse sequence in which TI was established as equal to the fat null point for purpose of fat suppression. In the fast FLAIR pulse sequence, the water null point was increased by making TR longer. In the FLAIR pulse sequence, the longitudinal magnetization contrast is determined by TI. If TI is increased, T 2 -weighted contrast improves in the same way as increasing TR for the SE pulse sequence. Therefore, images should be taken with long TR and long TI, which are longer than TR and longer than the water null point. On the other hand, the fat null point is not affected by TR in the fast STIR pulse sequence. However, effective TE was affected by variation of the null point. This increased in proportion to the increase in effective TE. Our evaluation indicated that the fast STIR pulse sequence can control the extensive signals from fat in a short time. (author)

  17. Hyperintense Acute Reperfusion Marker on FLAIR in a Patient with Transient Ischemic Attack

    Directory of Open Access Journals (Sweden)

    Alex Förster

    2016-01-01

    Full Text Available The hyperintense acute reperfusion marker (HARM has initially been described in acute ischemic stroke. The phenomenon is caused by blood-brain barrier disruption following acute reperfusion and consecutive delayed gadolinium enhancement in the subarachnoid space on fluid attenuated inversion recovery (FLAIR images. Here we report the case of an 80-year-old man who presented with transient paresis and sensory loss in the right arm. Initial routine stroke MRI including diffusion- and perfusion-weighted imaging demonstrated no acute pathology. Follow-up MRI after three hours demonstrated subarachnoid gadolinium enhancement in the left middle cerebral artery territory consistent with HARM that completely resolved on follow-up MRI three days later. This case illustrates that even in transient ischemic attack patients disturbances of the blood-brain barrier may be present which significantly exceed the extent of acute ischemic lesions on diffusion-weighted imaging. Inclusion of FLAIR images with delayed acquisition after intravenous contrast agent application in MRI stroke protocols might facilitate the diagnosis of a recent acute ischemic stroke.

  18. Decreased hyperintense vessels on FLAIR images after endovascular recanalization of symptomatic internal carotid artery occlusion

    International Nuclear Information System (INIS)

    Liu Wenhua; Yin Qin; Yao Lingling; Zhu Shuanggen; Xu Gelin; Zhang Renliang; Ke Kaifu; Liu Xinfeng

    2012-01-01

    Background and purpose: Hyperintense vessels (HV) on fluid-attenuated inversion recovery (FLAIR) images were assumed to be explained by slow antegrade or retrograde leptomeningeal collateral flow related to extracranial or intracranial artery steno-occlusion. The aim of this study was to investigate the effect of recanalization after endovascular therapy of symptomatic internal carotid artery (ICA) occlusion on the presence of HV. Methods: Eleven patients with symptomatic ICA occlusion were retrospectively enrolled. Changes in the HV on FLAIR images were examined in affected hemisphere of each patient after successful treatment with endovascular recanalization (angioplasty, n = 3; stent-assisted angioplasty, n = 8). The relationship between postoperative changes in the HV and Thrombolysis In Cerebral Ischemia (TICI) scale (I-III) was assessed. Results: After operation, HV of the 11 affected hemispheres were showed to be decreased (n = 3) or disappeared (n = 8) in treated side. The median interval between pre- and postoperative MRI examinations was 97.0 h (range, from 69. to 48.7 h). Of the 8 patients with disappeared HV, 7 achieved high TICI grade flow (III) and 1 had relatively low TICI grade flow (IIc) in treated side. However, all the 3 patients with decreased HV were found to be relatively low TICI grade flow (IIc). Conclusion: Our data indicate that endovascular recanalization of ICA occlusion was effective for decreasing HV. Postoperative decrease in HV can be considered as a marker for hemodynamic improvement.

  19. 3D recovery of human gaze in natural environments

    Science.gov (United States)

    Paletta, Lucas; Santner, Katrin; Fritz, Gerald; Mayer, Heinz

    2013-01-01

    The estimation of human attention has recently been addressed in the context of human robot interaction. Today, joint work spaces already exist and challenge cooperating systems to jointly focus on common objects, scenes and work niches. With the advent of Google glasses and increasingly affordable wearable eye-tracking, monitoring of human attention will soon become ubiquitous. The presented work describes for the first time a method for the estimation of human fixations in 3D environments that does not require any artificial landmarks in the field of view and enables attention mapping in 3D models. It enables full 3D recovery of the human view frustum and the gaze pointer in a previously acquired 3D model of the environment in real time. The study on the precision of this method reports a mean projection error ≈1.1 cm and a mean angle error ≈0.6° within the chosen 3D model - the precision does not go below the one of the technical instrument (≈1°). This innovative methodology will open new opportunities for joint attention studies as well as for bringing new potential into automated processing for human factors technologies.

  20. Single-frame 3D human pose recovery from multiple views

    NARCIS (Netherlands)

    Hofmann, M.; Gavrila, D.M.

    2009-01-01

    We present a system for the estimation of unconstrained 3D human upper body pose from multi-camera single-frame views. Pose recovery starts with a shape detection stage where candidate poses are generated based on hierarchical exemplar matching in the individual camera views. The hierarchy used in

  1. Quantification of traumatic meningeal injury using dynamic contrast enhanced (DCE) fluid-attenuated inversion recovery (FLAIR) imaging

    Science.gov (United States)

    Castro, Marcelo A.; Williford, Joshua P.; Cota, Martin R.; MacLaren, Judy M.; Dardzinski, Bernard J.; Latour, Lawrence L.; Pham, Dzung L.; Butman, John A.

    2016-03-01

    Traumatic meningeal injury is a novel imaging marker of traumatic brain injury, which appears as enhancement of the dura on post-contrast T2-weighted FLAIR images, and is likely associated with inflammation of the meninges. Dynamic Contrast Enhanced MRI provides a better discrimination of abnormally perfused regions. A method to properly identify those regions is presented. Images of seventeen patients scanned within 96 hours of head injury with positive traumatic meningeal injury were normalized and aligned. The difference between the pre- and last post-contrast acquisitions was segmented and voxels in the higher class were spatially clustered. Spatial and morphological descriptors were used to identify the regions of enhancement: a) centroid; b) distance to the brain mask from external voxels; c) distance from internal voxels; d) size; e) shape. The method properly identified thirteen regions among all patients. The method failed in one case due to the presence of a large brain lesion that altered the mask boundaries. Most false detections were correctly rejected resulting in a sensitivity and specificity of 92.9% and 93.6%, respectively.

  2. DWI-ASPECTS (Diffusion-Weighted Imaging-Alberta Stroke Program Early Computed Tomography Scores) and DWI-FLAIR (Diffusion-Weighted Imaging-Fluid Attenuated Inversion Recovery) Mismatch in Thrombectomy Candidates: An Intrarater and Interrater Agreement Study.

    Science.gov (United States)

    Fahed, Robert; Lecler, Augustin; Sabben, Candice; Khoury, Naim; Ducroux, Célina; Chalumeau, Vanessa; Botta, Daniele; Kalsoum, Erwah; Boisseau, William; Duron, Loïc; Cabral, Dominique; Koskas, Patricia; Benaïssa, Azzedine; Koulakian, Hasmik; Obadia, Michael; Maïer, Benjamin; Weisenburger-Lile, David; Lapergue, Bertrand; Wang, Adrien; Redjem, Hocine; Ciccio, Gabriele; Smajda, Stanislas; Desilles, Jean-Philippe; Mazighi, Mikaël; Ben Maacha, Malek; Akkari, Inès; Zuber, Kevin; Blanc, Raphaël; Raymond, Jean; Piotin, Michel

    2018-01-01

    We aimed to study the intrarater and interrater agreement of clinicians attributing DWI-ASPECTS (Diffusion-Weighted Imaging-Alberta Stroke Program Early Computed Tomography Scores) and DWI-FLAIR (Diffusion-Weighted Imaging-Fluid Attenuated Inversion Recovery) mismatch in patients with acute ischemic stroke referred for mechanical thrombectomy. Eighteen raters independently scored anonymized magnetic resonance imaging scans of 30 participants from a multicentre thrombectomy trial, in 2 different reading sessions. Agreement was measured using Fleiss κ and Cohen κ statistics. Interrater agreement for DWI-ASPECTS was slight (κ=0.17 [0.14-0.21]). Four raters (22.2%) had a substantial (or higher) intrarater agreement. Dichotomization of the DWI-ASPECTS (0-5 versus 6-10 or 0-6 versus 7-10) increased the interrater agreement to a substantial level (κ=0.62 [0.48-0.75] and 0.68 [0.55-0.79], respectively) and more raters reached a substantial (or higher) intrarater agreement (17/18 raters [94.4%]). Interrater agreement for DWI-FLAIR mismatch was moderate (κ=0.43 [0.33-0.57]); 11 raters (61.1%) reached a substantial (or higher) intrarater agreement. Agreement between clinicians assessing DWI-ASPECTS and DWI-FLAIR mismatch may not be sufficient to make repeatable clinical decisions in mechanical thrombectomy. The dichotomization of the DWI-ASPECTS (0-5 versus 0-6 or 0-6 versus 7-10) improved interrater and intrarater agreement, however, its relevance for patients selection for mechanical thrombectomy needs to be validated in a randomized trial. © 2017 American Heart Association, Inc.

  3. Comparison of T1-weighted fast spin-echo and T1-weighted fluid-attenuated inversion recovery images of the lumbar spine at 3.0 Tesla

    International Nuclear Information System (INIS)

    Lavdas, Eleftherios; Vlychou, Marianna; Arikidis, Nikos; Kapsalaki, Eftychia; Roka, Violetta; Fezoulidis, Ioannis V.

    2010-01-01

    Background: T1-weighted fluid-attenuated inversion recovery (FLAIR) sequence has been reported to provide improved contrast between lesions and normal anatomical structures compared to T1-weighted fast spin-echo (FSE) imaging at 1.5T regarding imaging of the lumbar spine. Purpose: To compare T1-weighted FSE and fast T1-weighted FLAIR imaging in normal anatomic structures and degenerative and metastatic lesions of the lumbar spine at 3.0T. Material and Methods: Thirty-two consecutive patients (19 females, 13 males; mean age 44 years, range 30-67 years) with lesions of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted FSE and fast T1-weighted FLAIR sequences. Both qualitative and quantitative analyses measuring the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and relative contrast (ReCon) between degenerative and metastatic lesions and normal anatomic structures were conducted, comparing these sequences. Results: On quantitative evaluation, SNRs of cerebrospinal fluid (CSF), nerve root, and fat around the root of fast T1-weighted FLAIR imaging were significantly lower than those of T1-weighted FSE images (P<0.001). CNRs of normal spinal cord/CSF and disc herniation/ CSF for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted FSE images (P<0.001). ReCon of normal spinal cord/CSF, disc herniation/CSF, and vertebral lesions/CSF for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted FSE images (P<0.001). On qualitative evaluation, it was found that CSF nulling and contrast at the spinal cord (cauda equina)/CSF interface for T1-weighted FLAIR images were significantly superior compared to those for T1-weighted FSE images (P<0.001), and the disc/spinal cord (cauda equina) interface was better for T1-weighted FLAIR images (P<0.05). Conclusion: The T1-weighted FLAIR sequence may be considered as the preferred lumbar spine imaging

  4. Visualization of white matter tracts using a non-diffusion weighted magnetic resonance imaging method: does intravenous gadolinium injection four hours prior to the examination affect the visualization of white matter tracts?

    Directory of Open Access Journals (Sweden)

    Masahiro Yamazaki

    Full Text Available OBJECTIVES: Visualization of white matter (WM-tracts such as the corticospinal tract (CST, medial lemniscus (ML, and superior cerebellar peduncle (SCP using delayed enhanced (DE-heavily T2-weighted three-dimensional fluid-attenuated inversion-recovery (hT2w-3D-FLAIR imaging has recently been reported. In that report, all patients were clinically suspected of having Ménière's disease, because DE-hT2w-3D-FLAIR imaging of the inner ear has been reported to separately visualize perilymph and endolymph fluid and can identify the presence of endolymphatic hydrops. Therefore, the previous report could not rule out the possible effect of delayed enhancement. From this perspective, the purpose of this study was to elucidate if the use of gadolinium affects the visualization of WM-tracts on hT2w-3D-FLAIR. MATERIALS AND METHODS: The records of nine patients with suspected Ménière's disease who underwent plain (P and DE-hT2w-3D-FLAIR by 3-Tesla were retrospectively analyzed. The regions of interest were set on the CST, ML, and SCP, and on contiguous brain parenchyma: The thalamus (Th, pontine parenchyma (PP, and cerebellar parenchyma (CP, respectively. The signal intensity ratio between each WM-tract and the relevant contiguous brain parenchyma was calculated for both P- and DE-hT2w-3D-FLAIR images, and statistically compared using paired t-tests. RESULTS: The CST/Th signal intensity ratio was 3.75±0.67 on P-hT2w-3D-FLAIR and 3.62±0.50 on DE-hT2w-3D-FLAIR (p = 0.24. The ML/PP signal intensity ratio was 2.19±0.59 on P-hT2w-3D-FLAIR and 2.08±0.53 on DE-hT2w-3D-FLAIR (p = 0.25. The SCP/CP signal intensity ratio was 4.08±0.91 on P-hT2w-3D-FLAIR and 4.04±0.96 on DE-hT2w-3D-FLAIR (p = 0.43. There were no significant differences in the signal intensity ratios between P- and DE-hT2w-3D-FLAIR images. CONCLUSIONS: The use of gadolinium is not necessary for visualization of WM-tracts using hT2w-3D-FLAIR, and P-hT2w-3D-FLAIR without gadolinium may

  5. FLAIR* to visualize veins in white matter lesions: A new tool for the diagnosis of multiple sclerosis?

    International Nuclear Information System (INIS)

    Campion, T.; Turner, B.P.; Schmierer, K.; Smith, R.J.P.; Altmann, D.R.; Brito, G.C.; Evanson, J.; George, I.C.; Sati, P.; Reich, D.S.; Miquel, M.E.

    2017-01-01

    To explore the potential of a post-processing technique combining FLAIR and T_2* (FLAIR*) to distinguish between lesions caused by multiple sclerosis (MS) from cerebral small vessel disease (SVD) in a clinical setting. FLAIR and T_2* head datasets acquired at 3T of 25 people with relapsing MS (pwRMS) and ten with pwSVD were used. After post-processing, FLAIR* maps were used to determine the proportion of white matter lesions (WML) showing the 'vein in lesion' sign (VIL), a characteristic histopathological feature of MS plaques. Sensitivity and specificity of MS diagnosis were examined on the basis of >45% VIL"+ and >60% VIL"+ WML, and compared with current dissemination in space (DIS) MRI criteria. All pwRMS had >45% VIL"+ WML (range 58-100%) whilst in pwSVD the proportion of VIL"+ WML was significantly lower (0-64%; mean 32±20%). Sensitivity based on >45% VIL"+ was 100% and specificity 80% whilst with >60% VIL"+ as the criterion, sensitivity was 96% and specificity 90%. DIS criteria had 96% sensitivity and 40% specificity. FLAIR* enables VIL"+ WML detection in a clinical setting, facilitating differentiation of MS from SVD based on brain MRI. (orig.)

  6. Iodine-124 PET dosimetry in differentiated thyroid cancer: recovery coefficient in 2D and 3D modes for PET(/CT) systems

    Energy Technology Data Exchange (ETDEWEB)

    Jentzen, Walter; Freudenberg, Lutz; Brandau, Wolfgang; Bockisch, Andreas [Universitaet Duisburg-Essen, Klinik fuer Nuklearmedizin, Essen (Germany); Weise, Reiner; Burchert, Wolfgang [Institut fuer Radiologie, Nuklearmedizin und Molekulare Bildgebung, Herz- und Diabeteszentrum NRW, Bad Oeynhausen (Germany); Kupferschlaeger, Juergen; Bares, Ronald [Universitaet Tuebingen, Klinik fuer Nuklearmedizin, Tuebingen (Germany)

    2008-03-15

    This study evaluated the absolute quantification of iodine-124 ({sup 124}I) activity concentration with respect to the use of this isotope for dosimetry before therapies with {sup 131}I or {sup 131}I-labeled radiotherapeuticals. The recovery coefficients of positron emission tomography(/computed tomography) PET(/CT) systems using {sup 124}I were determined using phantoms and then validated under typical conditions observed in differentiated thyroid cancer (DTC) patients. Transversal spatial resolution and recovery measurements with {sup 124}I and with fluorine-18 ({sup 18}F) as the reference were performed using isotope-containing line sources embedded in water and six isotope-containing spheres 9.7 to 37.0 mm in diameter placed in water-containing body and cylinder phantoms. The cylinder phantom spheres were filled with {sup 18}F only. Measurements in two-dimensional (2D) and three-dimensional (3D) modes were performed using both stand-alone PET (EXACT HR{sup +}) and combined PET/CT (BIOGRAPH EMOTION DUO) systems. Recovery comparison measurements were additionally performed on a GE ADVANCE PET system using the cylinder phantom. The recovery coefficients were directly determined using the activity concentration of circular regions of interest divided by the prepared activity concentration determined by the dose calibrator. The recovery correction method was validated using three consecutive scans of the body phantom under our {sup 124}I PET(/CT) protocol for DTC patients. Compared with that of {sup 18}F, transversal spatial resolution of {sup 124}I was slightly, but statistically significantly degraded (7.4 mm vs. 8.3 mm, P<0.002). Using the body phantom, recovery was lower for {sup 124}I than for {sup 18}F in both 2D and 3D modes. The {sup 124}I recovery coefficient of the largest sphere was significantly higher in 2D than in 3D mode (81% vs. 75%, P=0.03). Remarkably, the {sup 18}F recovery coefficient for the largest sphere significantly deviated from unity

  7. Seven-Tesla Magnetization Transfer Imaging to Detect Multiple Sclerosis White Matter Lesions.

    Science.gov (United States)

    Chou, I-Jun; Lim, Su-Yin; Tanasescu, Radu; Al-Radaideh, Ali; Mougin, Olivier E; Tench, Christopher R; Whitehouse, William P; Gowland, Penny A; Constantinescu, Cris S

    2018-03-01

    Fluid-attenuated inversion recovery (FLAIR) imaging at 3 Tesla (T) field strength is the most sensitive modality for detecting white matter lesions in multiple sclerosis. While 7T FLAIR is effective in detecting cortical lesions, it has not been fully optimized for visualization of white matter lesions and thus has not been used for delineating lesions in quantitative magnetic resonance imaging (MRI) studies of the normal appearing white matter in multiple sclerosis. Therefore, we aimed to evaluate the sensitivity of 7T magnetization-transfer-weighted (MT w ) images in the detection of white matter lesions compared with 3T-FLAIR. Fifteen patients with clinically isolated syndrome, 6 with multiple sclerosis, and 10 healthy participants were scanned with 7T 3-dimensional (D) MT w and 3T-2D-FLAIR sequences on the same day. White matter lesions visible on either sequence were delineated. Of 662 lesions identified on 3T-2D-FLAIR images, 652 were detected on 7T-3D-MT w images (sensitivity, 98%; 95% confidence interval, 97% to 99%). The Spearman correlation coefficient between lesion loads estimated by the two sequences was .910. The intrarater and interrater reliability for 7T-3D-MT w images was good with an intraclass correlation coefficient (ICC) of 98.4% and 81.8%, which is similar to that for 3T-2D-FLAIR images (ICC 96.1% and 96.7%). Seven-Tesla MT w sequences detected most of the white matter lesions identified by FLAIR at 3T. This suggests that 7T-MT w imaging is a robust alternative for detecting demyelinating lesions in addition to 3T-FLAIR. Future studies need to compare the roles of optimized 7T-FLAIR and of 7T-MT w imaging. © 2017 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  8. FLAIR* to visualize veins in white matter lesions: A new tool for the diagnosis of multiple sclerosis?

    Energy Technology Data Exchange (ETDEWEB)

    Campion, T.; Turner, B.P.; Schmierer, K. [Queen Mary University of London, Blizard Institute (Neuroscience), London (United Kingdom); Barts Health NHS Trust, Emergency Care and Acute Medicine Clinical Academic Group Neuroscience, The Royal London Hospital, London (United Kingdom); Smith, R.J.P. [Queen Mary University of London, Blizard Institute (Neuroscience), London (United Kingdom); Gloucestershire Hospitals NHS Trust, Cheltenham (United Kingdom); Altmann, D.R. [London School of Hygiene and Tropical Medicine, Department of Medical Statistics, London (United Kingdom); Brito, G.C. [Queen Mary University of London, Blizard Institute (Neuroscience), London (United Kingdom); Evanson, J. [Barts Health NHS Trust, Emergency Care and Acute Medicine Clinical Academic Group Neuroscience, The Royal London Hospital, London (United Kingdom); George, I.C. [NIH, Translational Neuroradiology Section, National Institute of Neurological Disorders and Stroke, Bethesda, MD (United States); Yale School of Medicine, Department of Neurology, New Haven, CT (United States); Sati, P.; Reich, D.S. [NIH, Translational Neuroradiology Section, National Institute of Neurological Disorders and Stroke, Bethesda, MD (United States); Miquel, M.E. [Barts Health NHS Trust, Emergency Care and Acute Medicine Clinical Academic Group Neuroscience, The Royal London Hospital, London (United Kingdom); Queen Mary University of London, William Harvey Research Institute (Cardiovascular Biomedical Research Unit), London (United Kingdom)

    2017-10-15

    To explore the potential of a post-processing technique combining FLAIR and T{sub 2}* (FLAIR*) to distinguish between lesions caused by multiple sclerosis (MS) from cerebral small vessel disease (SVD) in a clinical setting. FLAIR and T{sub 2}* head datasets acquired at 3T of 25 people with relapsing MS (pwRMS) and ten with pwSVD were used. After post-processing, FLAIR* maps were used to determine the proportion of white matter lesions (WML) showing the 'vein in lesion' sign (VIL), a characteristic histopathological feature of MS plaques. Sensitivity and specificity of MS diagnosis were examined on the basis of >45% VIL{sup +} and >60% VIL{sup +} WML, and compared with current dissemination in space (DIS) MRI criteria. All pwRMS had >45% VIL{sup +} WML (range 58-100%) whilst in pwSVD the proportion of VIL{sup +} WML was significantly lower (0-64%; mean 32±20%). Sensitivity based on >45% VIL{sup +} was 100% and specificity 80% whilst with >60% VIL{sup +} as the criterion, sensitivity was 96% and specificity 90%. DIS criteria had 96% sensitivity and 40% specificity. FLAIR* enables VIL{sup +} WML detection in a clinical setting, facilitating differentiation of MS from SVD based on brain MRI. (orig.)

  9. Contrast-enhanced fast fluid-attenuated inversion recovery MR imaging in patients with brain tumors

    International Nuclear Information System (INIS)

    Kim, Chan Kyo; Na, Dong Gyu; Ryoo, Wook Jae; Byun Hong Sik; Yoon, Hye Kyung; Kim, Jong hyun

    2000-01-01

    To assess the feasibility of contrast-enhanced fast fluid-attenuated inversion recovery (fast FLAIR) MR imaging in patients with brain tumors. This study involved 31 patients with pathologically proven brain tumors and nine with clinically diagnosed metastases. In all patients, T2-weighted, fast FLAIR, images were visual contrast-enhanced T1-weighted MR images were obtained. Contrast-enhanced fast FLAIR images were visually compared with other MR sequences in terms of tumor conspicuity. In order to distinguish tumor and surrounding edema, contrast-enhanced fast FLAIR images were compared with fast FLAIR and T2-weighted images. The tumor-to- white matter contrast-to-noise ratios (CNRs), as demonstrated by T2-weighted, fast FLAIR, contrast-enhanced fast FLAIR and contrast-enhanced T1-weighted imaging, were quantitatively assessed and compared. For the visual assessment of tumor conspicuity, contrast-enhanced fast FLAIR image imaging superior to fast FLAIR in 60% of cases (24/40), and superior to T2-weighted in 70% (28/40). Contrast-enhanced fast FLAIR imaging was inferior to contrast-enhanced T1-weighted in 58% of cases (23/40). For distinguishing between tumor and surrounding edema, contrast-enhanced fast FLAIR imaging was superior to fast FLAIR or T2-weighted in 22 of 27 tumors with peritumoral edema (81%). Quantitatively, CNR was the highest on contrast-enhanced fast FLAIR image and the lowest on fast FLAIR. For the detection of leptomeningeal metastases, contrast-enhanced fast FLAIR was partially superior to contrast-enhanced T1-weighted imaging in two of three high-grade gliomas. Although contrast-enhanced fast FLAIR imaging should not be seen as a replacement for conventional modalities, it provides additional informaton for assessment of the extent of glial cell tumors and leptomeningeal metastases in patients with brain tumors. (author)

  10. MR textural analysis on T2 FLAIR images for the prediction of true oligodendroglioma by the 2016 WHO genetic classification.

    Science.gov (United States)

    Rui, Wenting; Ren, Yan; Wang, Yin; Gao, Xinyi; Xu, Xiao; Yao, Zhenwei

    2017-11-15

    The genetic status of 1p/19q is important for differentiating oligodendroglioma, isocitrate-dehydrogenase (IDH)-mutant, and 1p/19q-codeleted from diffuse astrocytoma, IDH-mutant according to the 2016 World Health Organization (WHO) criteria. To assess the value of magnetic resonance textural analysis (MRTA) on T 2 fluid-attenuated inversion recovery (FLAIR) images for making a genetically integrated diagnosis of true oligodendroglioma by WHO guidelines. Retrospective case control. In all, there were 54 patients with a histopathological diagnosis of diffuse glioma (grade II). All were tested for IDH and 1p/19q. 3.0T, including T 2 FLAIR sequence, axial T 1 -weighted, and T 2 -weighted sequence. MRTA on a representative tumor region of interest (ROI) was made on preoperative T 2 FLAIR images around the area that had the largest diameter of solid tumor using Omni Kinetics software. Differences between IDH-mutant and 1p/19q-codeleted and IDH-mutant and 1p/19q-intact gliomas were analyzed by the Mann-Whitney rank sum test. Receiver operating characteristic curves (ROC) were created to assess MRTA diagnostic performance. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated with a cutoff value according to the Youden Index. Comparisons demonstrated significant differences in kurtosis (P = 0.007), energy (0.008), entropy (0.008), mean deviation (MD) (features comprising entropy (area under the curve [AUC] = 0.718, sensitivity = 97.1%) and energy (0.719, 94.1%) had the highest sensitivity but lower specificity (both 45%). Second-order features such as HGLRE (AUC = 0.750, sensitivity = 73.5%, specificity = 80.0%) and sum average (0.751, 70.6%, 80.0%) had relatively higher specificity, and all had AUC >0.7. MD had the highest diagnostic performance, with AUC = 0.878, sensitivity = 94.1%, specificity = 75.0%, PPV = 86.5%, and NPV = 88.2%. MRTA on T 2 FLAIR images may be

  11. Sampling of finite elements for sparse recovery in large scale 3D electrical impedance tomography

    International Nuclear Information System (INIS)

    Javaherian, Ashkan; Moeller, Knut; Soleimani, Manuchehr

    2015-01-01

    This study proposes a method to improve performance of sparse recovery inverse solvers in 3D electrical impedance tomography (3D EIT), especially when the volume under study contains small-sized inclusions, e.g. 3D imaging of breast tumours. Initially, a quadratic regularized inverse solver is applied in a fast manner with a stopping threshold much greater than the optimum. Based on assuming a fixed level of sparsity for the conductivity field, finite elements are then sampled via applying a compressive sensing (CS) algorithm to the rough blurred estimation previously made by the quadratic solver. Finally, a sparse inverse solver is applied solely to the sampled finite elements, with the solution to the CS as its initial guess. The results show the great potential of the proposed CS-based sparse recovery in improving accuracy of sparse solution to the large-size 3D EIT. (paper)

  12. Relationship between fluid-attenuated inversion-recovery (FLAIR) signal intensity and inflammatory mediator's levels in the hippocampus of patients with temporal lobe epilepsy and mesial temporal sclerosis.

    Science.gov (United States)

    Varella, Pedro Paulo Vasconcellos; Santiago, Joselita Ferreira Carvalho; Carrete, Henrique; Higa, Elisa Mieko Suemitsu; Yacubian, Elza Márcia Targas; Centeno, Ricardo Silva; Caboclo, Luís Otávio Sales Ferreira; Castro Neto, Eduardo Ferreira de; Canzian, Mauro; Amado, Débora; Cavalheiro, Esper Abrão; Naffah-Mazzacoratti, Maria da Graça

    2011-02-01

    We investigated a relationship between the FLAIR signal found in mesial temporal sclerosis (MTS) and inflammation. Twenty nine patients were selected through clinical and MRI analysis and submitted to cortico-amygdalo-hippocampectomy to seizure control. Glutamate, TNFα, IL1, nitric oxide (NO) levels and immunostaining against IL1β and CD45 was performed. Control tissues (n=10) were obtained after autopsy of patients without neurological disorders. The glutamate was decreased in the temporal lobe epilepsy (TLE) -MTS group (p<0.001), suggesting increased release of this neurotransmitter. The IL1β and TNFα were increased in the hippocampus (p<0.05) demonstrating an active inflammatory process. A positive linear correlation between FLAIR signal and NO and IL1β levels and a negative linear correlation between FLAIR signal and glutamate concentration was found. Lymphocytes infiltrates were present in hippocampi of TLE patients. These data showed an association between hippocampal signal alteration and increased inflammatory markers in TLE-MTS.

  13. Relationship between fluid-attenuated inversion-recovery (FLAIR signal intensity and inflammatory mediator's levels in the hippocampus of patients with temporal lobe epilepsy and mesial temporal sclerosis

    Directory of Open Access Journals (Sweden)

    Pedro Paulo Vasconcellos Varella

    2011-02-01

    Full Text Available We investigated a relationship between the FLAIR signal found in mesial temporal sclerosis (MTS and inflammation. Twenty nine patients were selected through clinical and MRI analysis and submitted to cortico-amygdalo-hippocampectomy to seizure control. Glutamate, TNFα, IL1, nitric oxide (NO levels and immunostaining against IL1β and CD45 was performed. Control tissues (n=10 were obtained after autopsy of patients without neurological disorders. The glutamate was decreased in the temporal lobe epilepsy (TLE -MTS group (p<0.001, suggesting increased release of this neurotransmitter. The IL1β and TNFα were increased in the hippocampus (p<0.05 demonstrating an active inflammatory process. A positive linear correlation between FLAIR signal and NO and IL1β levels and a negative linear correlation between FLAIR signal and glutamate concentration was found. Lymphocytes infiltrates were present in hippocampi of TLE patients. These data showed an association between hippocampal signal alteration and increased inflammatory markers in TLE-MTS.

  14. MRI based thrombolysis for FLAIR-negative stroke patients within 4.5-6h after symptom onset.

    Science.gov (United States)

    Wei, Xiao-Er; Zhou, Jia; Li, Wen-Bin; Zhao, Yu-Wu; Li, Ming-Hua; Li, Yue-Hua

    2017-01-15

    To investigate the feasibility of DWI-FLAIR mismatch in identifying patients who might benefit from thrombolytic therapy within 4.5-6h, we analyzed the data of 105 ischemic stroke patients with known time of symptom onset who underwent MRI within 6h of stroke and thrombolysis between December 2006 and December 2013. They were divided into three groups: symptom onset within 4.5h (n=66); 4.5-6h and FLAIR images negative (n=9); and 4.5-6h and FLAIR images positive (n=30). Outcome of thrombolysis was assessed for each group by recanalization rate, National Institutes of Health Stroke Scale (NIHSS) and modified Rankin Scale (mRS) scores. The results showed that mismatch between positive DWI and negative FLAIR images identified patients within 4.5h of symptom onset with sensitivity, specificity, positive predictive value and negative predictive value of 40.9%, 76.9%, and 75% and 43.5%. Recanalization rate, NIHSS score and mRS score were all better in both the 0-4.5h and 4.5-6h FLAIR-negative groups than in the 4.5-6h FLAIR-positive group (psymptom onset, patients with negative FLAIR images may benefit from thrombolysis therapy. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Influence of crosstalk on the fast fluid attenuated inversion recovery pulse sequence

    International Nuclear Information System (INIS)

    Urata, Tohru; Nonoshita, Koji; Miyazaki, Takayuki; Arima, Akira

    2000-01-01

    The influence of crosstalk on the fast fluid attenuated inversion recovery (fast FLAIR) pulse sequence was studied. On multislice fast FLAIR images, the water null point was shortened in comparison with that on single slice images owing to the crosstalk received from adjacent slices. That influence became greater with decreases in the slice gap and increases in the number of slices. The timing of crosstalk in each slice varied according to excitation order. The process of recovery of longitudinal magnetization changed according to differences in timing; thus, it was possible that the water null point changed in each slice. In brain images with thinner slice gaps, the signal intensity of CSF is increased by the effect of crosstalk. In order to eliminate changes in the water null point caused by crosstalk on fast FLAIR, the multislice sequence requires a sequence with interleaving based on the premise that slice gaps are set for more than 100% of slice thickness. (author)

  16. Influence of crosstalk on the fast fluid attenuated inversion recovery pulse sequence

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Tohru; Nonoshita, Koji; Miyazaki, Takayuki; Arima, Akira [Funabashi Municipal Medical Center, Chiba (Japan)

    2000-04-01

    The influence of crosstalk on the fast fluid attenuated inversion recovery (fast FLAIR) pulse sequence was studied. On multislice fast FLAIR images, the water null point was shortened in comparison with that on single slice images owing to the crosstalk received from adjacent slices. That influence became greater with decreases in the slice gap and increases in the number of slices. The timing of crosstalk in each slice varied according to excitation order. The process of recovery of longitudinal magnetization changed according to differences in timing; thus, it was possible that the water null point changed in each slice. In brain images with thinner slice gaps, the signal intensity of CSF is increased by the effect of crosstalk. In order to eliminate changes in the water null point caused by crosstalk on fast FLAIR, the multislice sequence requires a sequence with interleaving based on the premise that slice gaps are set for more than 100% of slice thickness. (author)

  17. Multi-view 3D human pose estimation combining single-frame recovery, temporal integration and model adaptation

    NARCIS (Netherlands)

    Hofmann, K.M.; Gavrilla, D.M.

    2009-01-01

    We present a system for the estimation of unconstrained 3D human upper body movement from multiple cameras. Its main novelty lies in the integration of three components: single frame pose recovery, temporal integration and model adaptation. Single frame pose recovery consists of a hypothesis

  18. Comparison of T2 and FLAIR imaging for target delineation in high grade gliomas

    International Nuclear Information System (INIS)

    Stall, Bronwyn; Zach, Leor; Ning, Holly; Ondos, John; Arora, Barbara; Shankavaram, Uma; Miller, Robert W; Citrin, Deborah; Camphausen, Kevin

    2010-01-01

    FLAIR and T2 weighted MRIs are used based on institutional preference to delineate high grade gliomas and surrounding edema for radiation treatment planning. Although these sequences have inherent physical differences there is limited data on the clinical and dosimetric impact of using either or both sequences. 40 patients with high grade gliomas consecutively treated between 2002 and 2008 of which 32 had pretreatment MRIs with T1, T2 and FLAIR available for review were selected for this study. These MRIs were fused with the treatment planning CT. Normal structures, clinical tumor volume (CTV) and planning tumor volume (PTV) were then defined on the T2 and FLAIR sequences. A Venn diagram analysis was performed for each pair of tumor volumes as well as a fractional component analysis to assess the contribution of each sequence to the union volume. For each patient the tumor volumes were compared in terms of total volume in cubic centimeters as well as anatomic location using a discordance index. The overlap of the tumor volumes with critical structures was calculated as a measure of predicted toxicity. For patients with MRI documented failures, the tumor volumes obtained using the different sequences were compared with the recurrent gross tumor volume (rGTV). The FLAIR CTVs and PTVs were significantly larger than the T2 CTVs and PTVs (p < 0.0001 and p = 0.0001 respectively). Based on the discordance index, the abnormality identified using the different sequences also differed in location. Fractional component analysis showed that the intersection of the tumor volumes as defined on both T2 and FLAIR defined the majority of the union volume contributing 63.6% to the CTV union and 82.1% to the PTV union. T2 alone uniquely identified 12.9% and 5.2% of the CTV and PTV unions respectively while FLAIR alone uniquely identified 25.7% and 12% of the CTV and PTV unions respectively. There was no difference in predicted toxicity to normal structures using T2 or FLAIR. At the

  19. Utility of coronal contrast-enhanced fat-suppressed FLAIR in the evaluation of optic neuropathy and atrophy.

    Science.gov (United States)

    Boegel, Kevin H; Tyan, Andrew E; Iyer, Veena R; Rykken, Jeffrey B; McKinney, Alexander M

    2017-01-01

    Evaluating chronic sequelae of optic neuritis, such as optic neuropathy with or without optic nerve atrophy, can be challenging on whole brain MRI. This study evaluated the utility of dedicated coronal contrast-enhanced fat-suppressed FLAIR (CE-FS-FLAIR) MR imaging to detect optic neuropathy and optic nerve atrophy. Over 4.5 years, a 3 mm coronal CE-FS-FLAIR sequence at 1.5T was added to the routine brain MRIs of 124 consecutive patients, 102 of whom had suspected or known demyelinating disease. Retrospective record reviews confirmed that 28 of these 102 had documented onset of optic neuritis >4 weeks prior to the brain MRI. These 28 were compared to the other 22 ("controls") of the 124 patients who lacked a history of demyelinating disease or visual symptoms. Using coronal CE-FS-FLAIR, two neuroradiologists separately graded each optic nerve (n = 50 patients, 100 total nerves) as either negative, equivocal, or positive for optic neuropathy or atrophy. The scoring was later repeated. The mean time from acute optic neuritis onset to MRI was 4.1 ± 4.6 years (range 34 days-17.4 years). Per individual nerve grading, the range of sensitivity, specificity, and accuracy of coronal CE-FS-FLAIR in detecting optic neuropathy was 71.4-77.1%, 93.8-95.4%, and 85.5-89.0%, respectively, with strong interobserver (k = 0.667 - 0.678, p optic atrophy, interobserver agreement was moderate (k = 0.437 - 0.484, p optic neuropathy years after the onset of acute optic neuritis, but is less useful in detecting optic nerve atrophy.

  20. Fast fluid-attenuated inversion-recovery MR image in the intracranial tumors: comparison with fast spin-echo image

    International Nuclear Information System (INIS)

    Choi, Hye Young; Kwang, Hyoen Joo; Baek, Seoung Yeon; Lee, Sun Wha

    1997-01-01

    To evaluate the significance of fluid-attenuated inversion recovery(FLAIR) magnetic resonance(MR) images for the diagnosis of intracranial tumors. MR imaging was used to study 15 patients with various intracranial tumors and were compared the findings according to fast spin echo and fast FLAIR images. In 12 of 15 patients, tumor signal intensities on FLAIR images were consistent with those shown on T2-weighted(T2W) images. In seven of eight patients who had cystic or necrotic components within the mass, FLAIR images showed isosignal intensity and in the other patient, high signal intensity was seen. There was variation in the signal intensity from cerebrospinal fluid(CSF). In 12 of 13 patients in whom edema was associated with tumor, FLAIR images were clearer than T2W images as their signal intensity was brighter. In eight patients, however, FLAIR and T2W images provided a similar definition of the margin between edema and tumor. In six patients with intratumoral hemorrhage except the chronic cystic stage. We concluded that in the diagnosis of intracranial tumors, FLAIR images can supplement conventional spin-echo images

  1. 3D shape recovery of a newborn skull using thin-plate splines.

    Science.gov (United States)

    Lapeer, R J; Prager, R W

    2000-01-01

    The objective of this paper is to construct a mesh-model of a newborn skull for finite element analysis to study its deformation when subjected to the forces present during labour. The current state of medical imaging technology has reached a level which allows accurate visualisation and shape recovery of biological organs and body-parts. However, a sufficiently large set of medical images cannot always be obtained, often because of practical or ethical reasons, and the requirement to recover the shape of the biological object of interest has to be met by other means. Such is the case for a newborn skull. A method to recover the three-dimensional (3D) shape from (minimum) two orthogonal atlas images of the object of interest and a homologous object is described. This method is based on matching landmarks and curves on the orthogonal images of the object of interest with corresponding landmarks and curves on the homologous or 'master'-object which is fully defined in 3D space. On the basis of this set of corresponding landmarks, a thin-plate spline function can be derived to warp from the 'master'-object space to the 'slave'-object space. This method is applied to recover the 3D shape of a newborn skull. Images from orthogonal view-planes are obtained from an atlas. The homologous object is an adult skull, obtained from CT-images made available by the Visible Human Project. After shape recovery, a mesh-model of the newborn skull is generated.

  2. Temporal pole signal abnormality on MR imaging in temporal lobe epilepsy with hippocampal sclerosis: a fluid-attenuated inversion-recovery study Anormalidade de sinal na imagem por RM do pólo temporal na epilepsia do lobo temporal com esclerose hipocampal: um estudo pela seqüência inversão recuperação com supressão da água livre (FLAIR

    Directory of Open Access Journals (Sweden)

    Henrique Carrete Junior

    2007-09-01

    Full Text Available OBJECTIVE: To determine the frequency and regional involvement of temporal pole signal abnormality (TPA in patients with hippocampal sclerosis (HS using fluid-attenuated inversion-recovery (FLAIR MR imaging, and to correlate this feature with history. METHOD: Coronal FLAIR images of the temporal pole were assessed in 120 patients with HS and in 30 normal subjects, to evaluate gray-white matter demarcation. RESULTS: Ninety (75% of 120 patients had associated TPA. The HS side made difference regarding the presence of TPA, with a left side prevalence (p=0.04, chi2 test. The anteromedial zone of temporal pole was affected in 27 (30% out of 90 patients. In 63 (70% patients the lateral zone were also affected. Patients with TPA were younger at seizure onset (p=0.018, but without association with duration of epilepsy. CONCLUSION: Our FLAIR study show temporal pole signal abnormality in 3/4 of patients with HS, mainly seen on the anteromedial region, with a larger prevalence when the left hippocampus was involved.OBJETIVO: Determinar a freqüência e o envolvimento regional da anormalidade de sinal do pólo temporal (APT em pacientes com esclerose hipocampal (EH utilizando seqüência inversão recuperação com supressão da água (FLAIR por RM, e correlacioná-la com a história. MÉTODO: Foram analisadas as imagens coronais FLAIR dos pólos temporais de 120 pacientes com EH e de 30 indivíduos normais, para avaliar a demarcação entre substâncias branca e cinzenta. RESULTADOS: Noventa (75% dos 120 pacientes tinham APT associada. Houve prevalência do lado esquerdo (p=0.04, chi2 teste na relação entre APT e o lado da EH. A zona ântero-medial estava acometida em 27 (30% destes pacientes. Em 63 (70% pacientes também a zona lateral estava acometida. Pacientes com APT apresentaram início da epilepsia quando mais jovens (p=0.018, porém sem associação com a sua duração. CONCLUSÃO: A seqüência FLAIR mostra haver ATP em 3/4 dos pacientes com EH

  3. An active robot vision system for real-time 3-D structure recovery

    Energy Technology Data Exchange (ETDEWEB)

    Juvin, D. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. d`Electronique et d`Instrumentation Nucleaire; Boukir, S.; Chaumette, F.; Bouthemy, P. [Rennes-1 Univ., 35 (France)

    1993-10-01

    This paper presents an active approach for the task of computing the 3-D structure of a nuclear plant environment from an image sequence, more precisely the recovery of the 3-D structure of cylindrical objects. Active vision is considered by computing adequate camera motions using image-based control laws. This approach requires a real-time tracking of the limbs of the cylinders. Therefore, an original matching approach, which relies on an algorithm for determining moving edges, is proposed. This method is distinguished by its robustness and its easiness to implement. This method has been implemented on a parallel image processing board and real-time performance has been achieved. The whole scheme has been successfully validated in an experimental set-up.

  4. An active robot vision system for real-time 3-D structure recovery

    International Nuclear Information System (INIS)

    Juvin, D.

    1993-01-01

    This paper presents an active approach for the task of computing the 3-D structure of a nuclear plant environment from an image sequence, more precisely the recovery of the 3-D structure of cylindrical objects. Active vision is considered by computing adequate camera motions using image-based control laws. This approach requires a real-time tracking of the limbs of the cylinders. Therefore, an original matching approach, which relies on an algorithm for determining moving edges, is proposed. This method is distinguished by its robustness and its easiness to implement. This method has been implemented on a parallel image processing board and real-time performance has been achieved. The whole scheme has been successfully validated in an experimental set-up

  5. Utility of coronal contrast-enhanced fat-suppressed FLAIR in the evaluation of optic neuropathy and atrophy

    Directory of Open Access Journals (Sweden)

    Kevin H. Boegel

    Full Text Available Background and purpose: Evaluating chronic sequelae of optic neuritis, such as optic neuropathy with or without optic nerve atrophy, can be challenging on whole brain MRI. This study evaluated the utility of dedicated coronal contrast-enhanced fat-suppressed FLAIR (CE-FS-FLAIR MR imaging to detect optic neuropathy and optic nerve atrophy. Materials and methods: Over 4.5 years, a 3 mm coronal CE-FS-FLAIR sequence at 1.5T was added to the routine brain MRIs of 124 consecutive patients, 102 of whom had suspected or known demyelinating disease. Retrospective record reviews confirmed that 28 of these 102 had documented onset of optic neuritis >4 weeks prior to the brain MRI. These 28 were compared to the other 22 (“controls” of the 124 patients who lacked a history of demyelinating disease or visual symptoms. Using coronal CE-FS-FLAIR, two neuroradiologists separately graded each optic nerve (n = 50 patients, 100 total nerves as either negative, equivocal, or positive for optic neuropathy or atrophy. The scoring was later repeated. Results: The mean time from acute optic neuritis onset to MRI was 4.1 ± 4.6 years (range 34 days-17.4 years. Per individual nerve grading, the range of sensitivity, specificity, and accuracy of coronal CE-FS-FLAIR in detecting optic neuropathy was 71.4–77.1%, 93.8–95.4%, and 85.5–89.0%, respectively, with strong interobserver (k = 0.667 − 0.678, p < 0.0001, and intraobserver (k = 0.706 − 0.763, p < 0.0001 agreement. For optic atrophy, interobserver agreement was moderate (k = 0.437 − 0.484, p < 0.0001, while intraobserver agreement was moderate-strong (k = 0.491 − 0.596, p < 0.0001. Conclusion: Coronal CE-FS-FLAIR is quite specific in detecting optic neuropathy years after the onset of acute optic neuritis, but is less useful in detecting optic nerve atrophy. Keywords: Optic

  6. Fast spine echo and fast fluid attenuated inversion recovery sequences in multiple sclerosis

    International Nuclear Information System (INIS)

    Paolillo, Andrea; Giugni, Elisabetta; Bozzao, Alessandro; Bastianello, Stefano

    1997-01-01

    Fast spin echo (FSE) and fast fluid attenuated inversion recovery (fast-FLAIR) sequences, were compared with conventional spin echo (CSE) in quantitating multiple sclerosis (MS) lesion burden. For each sequence, the total number and volume of MS lesions were calculated in 38 remitting multiple sclerosis patients using a semiautomated lesion detection program. Conventional spin echo, fast spin echo, and fast fluid attenuated inversion recovery image were reported on randomly and at different times by two expert observers. Interobserver differences, the time needed to quantitative multiple sclerosis lesions and lesion signal intensity (contrast-to-noise ratio and overall contrast) were considered. The lesions were classified by site into infratentorial, white matter and cortical/subcortical. A total of 2970 lesions with a volume of 961.7 cm 3 was calculated on conventional spin echo images. Fast spin echo images depicted fewer (16.6%; p < .005) and smaller (24.9%; p < .0001) lesions and the differences were statistically significant. Despite an overall nonsignificant reduction for fast-FLAIR images (-5% and 4.8% for lesion number and volume, respectively), significantly lower values (lesion number: p < 0.1; volume: p < .04)were observed for infratentorial lesions, while significantly higher values were seen for cortical/subcortical lesions (lesion number: p < .01; volume: p < .02). A higher lesion/white matter contrast (p < .002), a significant time saving for lesion burden quantitation (p < .05) and very low interobserver variability were found in favor of fast-FLAIR. Our data suggest that, despite the limitations regarding infratentorial lesions, fast-FLAIR sequences are indicated in R studies because of their good identification of cortical/subcortical lesions, almost complete interobserver agreement, higher contrast-to-noise ratio and limited time needed for semiautomated quantitation

  7. Contributions of an adiabatic initial inversion pulse and K-space Re-ordered by inversion-time at each slice position (KRISP) to control of CSF artifacts and visualization of the brain in FLAIR magnetic resonance imaging

    International Nuclear Information System (INIS)

    Curati, Walter L.; Oatridge, Angela; Herlihy, Amy H.; Hajnal, Joseph V.; Puri, Basant K.; Bydder, Graeme M.

    2001-01-01

    AIM: The aim of this study was to compare the performance of three fluid attenuated inversion recovery (FLAIR) pulse sequences for control of cerebrospinal fluid (CSF) and blood flow artifacts in imaging of the brain. The first of these sequences had an initial sinc inversion pulse which was followed by conventional k-space mapping. The second had an initial sinc inversion pulse followed by k-space re-ordered by inversion time at each slice position (KRISP) and the third had an adiabatic initial inversion pulse followed by KRISP. MATERIALS AND METHODS: Ten patients with established disease were studied with all three pulse sequences. Seven were also studied with the adiabatic KRISP sequence after contrast enhancement. Their images were evaluated for patient motion artifact, CSF and blood flow artifact as well as conspicuity of the cortex, meninges, ventricular system, brainstem and cerebellum. The conspicuity of lesions and the degree of enhancement were also evaluated. RESULTS: Both the sinc and adiabatic KRISP FLAIR sequences showed better control of CSF and blood flow artifacts than the conventional FLAIR sequence. In addition the adiabatic KRISP FLAIR sequence showed better control of CSF artifact at the inferior aspect of the posterior fossa. The lesion conspicuity was similar for each of the FLAIR sequences as was the degree of contrast enhancement to that shown with a T 1 weighted spin echo sequence. CONCLUSION: The KRISP FLAIR sequence controls high signal artifacts from CSF flow and blood flow and the adiabatic pulse controls high signal artifacts due to inadequate inversion of the CSF magnetization at the periphery of the head transmitter coil. The KRISP FLAIR sequence also improves cortical and meningeal definition as a result of an edge enhancement effect. The effects are synergistic and can be usefully combined in a single pulse sequence. Curati, W.L. et al. (2001)

  8. Convergence and resolution recovery of block-iterative EM algorithms modeling 3D detector response in SPECT

    International Nuclear Information System (INIS)

    Lalush, D.S.; Tsui, B.M.W.; Karimi, S.S.

    1996-01-01

    We evaluate fast reconstruction algorithms including ordered subsets-EM (OS-EM) and Rescaled Block Iterative EM (RBI-EM) in fully 3D SPECT applications on the basis of their convergence and resolution recovery properties as iterations proceed. Using a 3D computer-simulated phantom consisting of 3D Gaussian objects, we simulated projection data that includes only the effects of sampling and detector response of a parallel-hole collimator. Reconstructions were performed using each of the three algorithms (ML-EM, OS-EM, and RBI-EM) modeling the 3D detector response in the projection function. Resolution recovery was evaluated by fitting Gaussians to each of the four objects in the iterated image estimates at selected intervals. Results show that OS-EM and RBI-EM behave identically in this case; their resolution recovery results are virtually indistinguishable. Their resolution behavior appears to be very similar to that of ML-EM, but accelerated by a factor of twenty. For all three algorithms, smaller objects take more iterations to converge. Next, we consider the effect noise has on convergence. For both noise-free and noisy data, we evaluate the log likelihood function at each subiteration of OS-EM and RBI-EM, and at each iteration of ML-EM. With noisy data, both OS-EM and RBI-EM give results for which the log-likelihood function oscillates. Especially for 180-degree acquisitions, RBI-EM oscillates less than OS-EM. Both OS-EM and RBI-EM appear to converge to solutions, but not to the ML solution. We conclude that both OS-EM and RBI-EM can be effective algorithms for fully 3D SPECT reconstruction. Both recover resolution similarly to ML-EM, only more quickly

  9. Cognitive Function and 3-Tesla Magnetic Resonance Imaging Tractography of White Matter Hyperintensities in Elderly Persons

    OpenAIRE

    Reginold, William; Luedke, Angela C.; Tam, Angela; Itorralba, Justine; Fernandez-Ruiz, Juan; Reginold, Jennifer; Islam, Omar; Garcia, Angeles

    2015-01-01

    Background/Aims: This study used 3-Tesla magnetic resonance imaging (MRI) tractography to determine if there was an association between tracts crossing white matter hyperintensities (WMH) and cognitive function in elderly persons. Methods: Brain T2-weighted fluid-attenuated inversion recovery (FLAIR) and diffusion tensor MRI scans were acquired in participants above the age of 60 years. Twenty-six persons had WMH identified on T2 FLAIR scans. They completed a battery of neuropsychological tes...

  10. Influence of fluid-attenuated inversion-recovery on stroke apparent diffusion coefficient measurements and its clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Ni Jianming [Medical Imaging Department, Wuxi Second Hospital Affiliated Nanjing Medical University, 68 Zhong Shan Road, Wuxi, Jiangsu Province 214002 (China); Radiology Department, Huashan Hospital, Shanghai Medical College, Fudan University, 12 Urumqi Middle Road, Shanghai 200040 (China); Nuclear Medicine Department, Renji Hospital, Medical School of Jiaotong University, Dongfang Road 1630, Shanghai 200127 (China); Mogensen, Monique A. [Department of Radiology, Division of Neuroradiology, University of Southern California, Los Angeles, CA (United States); Chen Zengai [Radiology Department, Huashan Hospital, Shanghai Medical College, Fudan University, 12 Urumqi Middle Road, Shanghai 200040 (China); Nuclear Medicine Department, Renji Hospital, Medical School of Jiaotong University, Dongfang Road 1630, Shanghai 200127 (China); Shuang Chen; Shen Tianzhen [Radiology Department, Huashan Hospital, Shanghai Medical College, Fudan University, 12 Urumqi Middle Road, Shanghai 200040 (China); Huang Gang, E-mail: huang2802@163.co [Nuclear Medicine Department, Renji Hospital, Medical School of Jiaotong University, Dongfang Road 1630, Shanghai 200127 (China)

    2010-08-15

    Background and purpose: The application of a fluid-attenuated inversion-recovery pulse with a conventional diffusion-weighted MRI sequence (FLAIR DWI) decreases the partial volume effects from cerebrospinal fluid on apparent diffusion coefficient (ADC) measurements. For this reason, FLAIR DWI may be more useful in the evaluation of ischemic stroke, but few studies have looked at the effect of FLAIR on ADC measurements in this setting. This study quantitatively compares FLAIR DWI and conventional DWI in ischemic stroke of varying ages to assess the potential advantages of this technique. Methods: We respectively analyzed 139 DWI studies in patients with ischemic stroke with and without FLAIR at varying time points ranging from hyperacute to chronic. ADC values were measured in each lesion, as well as in the contralateral normal side. Comparisons were made between the ADC values obtained from the DWI sequences with and without FLAIR for both the lesion and the normal contralateral side. Results: The ADC measurements within the ischemic lesion were very similar on FLAIR DWI and conventional DWI for lesions less than 14 days old (p > 0.05), but were significantly decreased on FLAIR DWI for lesions between 15 and 30 days old and in lesions >31 days old (chronic stage) (p < 0.01). The contralateral ADC values were all significantly decreased on the FLAIR DWI sequence compared with conventional DWI (p < 0.01). Conclusions: The application of an inversion pulse does not significantly affect the ADC values for early stage ischemic stroke (less than 14 days from symptom onset), but results in a more accurate relative ADC measurement by reducing the cerebrospinal fluid partial volume effects of the normal contralateral side. In addition, combined with the conventional DWI, FLAIR DWI may be helpful in determining the age of ischemic lesions.

  11. Iodine-124 PET dosimetry in differentiated thyroid cancer: recovery coefficient in 2D and 3D modes for PET(/CT) systems.

    Science.gov (United States)

    Jentzen, Walter; Weise, Reiner; Kupferschläger, Jürgen; Freudenberg, Lutz; Brandau, Wolfgang; Bares, Ronald; Burchert, Wolfgang; Bockisch, Andreas

    2008-03-01

    This study evaluated the absolute quantification of iodine-124 ((124)I) activity concentration with respect to the use of this isotope for dosimetry before therapies with (131)I or (131)I-labeled radiotherapeuticals. The recovery coefficients of positron emission tomography(/computed tomography) PET(/CT) systems using (124)I were determined using phantoms and then validated under typical conditions observed in differentiated thyroid cancer (DTC) patients. Transversal spatial resolution and recovery measurements with (124)I and with fluorine-18 ((18)F) as the reference were performed using isotope-containing line sources embedded in water and six isotope-containing spheres 9.7 to 37.0 mm in diameter placed in water-containing body and cylinder phantoms. The cylinder phantom spheres were filled with (18)F only. Measurements in two-dimensional (2D) and three-dimensional (3D) modes were performed using both stand-alone PET (EXACT HR(+)) and combined PET/CT (BIOGRAPH EMOTION DUO) systems. Recovery comparison measurements were additionally performed on a GE ADVANCE PET system using the cylinder phantom. The recovery coefficients were directly determined using the activity concentration of circular regions of interest divided by the prepared activity concentration determined by the dose calibrator. The recovery correction method was validated using three consecutive scans of the body phantom under our (124)I PET(/CT) protocol for DTC patients. Compared with that of (18)F, transversal spatial resolution of (124)I was slightly, but statistically significantly degraded (7.4 mm vs. 8.3 mm, P or =12.6 mm in diameter. Recovery correction is mandatory for (124)I PET quantification, even for large structures. To ensure accurate dosimetry, thorough absolute recovery measurements must be individually established for the particular PET scanner and radionuclide to be used.

  12. Temporal pole signal abnormality on MR imaging in temporal lobe epilepsy with hippocampal sclerosis: a fluid-attenuated inversion-recovery study.

    Science.gov (United States)

    Carrete, Henrique; Abdala, Nitamar; Lin, Kátia; Caboclo, Luís Otávio; Centeno, Ricardo Silva; Sakamoto, Américo Ceiki; Szjenfeld, Jacob; Nogueira, Roberto Gomes; Yacubian, Elza Márcia Targas

    2007-09-01

    To determine the frequency and regional involvement of temporal pole signal abnormality (TPA) in patients with hippocampal sclerosis (HS) using fluid-attenuated inversion-recovery (FLAIR) MR imaging, and to correlate this feature with history. Coronal FLAIR images of the temporal pole were assessed in 120 patients with HS and in 30 normal subjects, to evaluate gray-white matter demarcation. Ninety (75%) of 120 patients had associated TPA. The HS side made difference regarding the presence of TPA, with a left side prevalence (p=0.04, chi2 test). The anteromedial zone of temporal pole was affected in 27 (30%) out of 90 patients. In 63 (70%) patients the lateral zone were also affected. Patients with TPA were younger at seizure onset (p=0.018), but without association with duration of epilepsy. Our FLAIR study show temporal pole signal abnormality in 3/4 of patients with HS, mainly seen on the anteromedial region, with a larger prevalence when the left hippocampus was involved.

  13. Temporal pole signal abnormality on MR imaging in temporal lobe epilepsy with hippocampal sclerosis: a fluid-attenuated inversion-recovery study

    International Nuclear Information System (INIS)

    Carrete Junior, Henrique; Abdala, Nitamar; Szjenfeld, Jacob; Nogueira, Roberto Gomes; Lin, Katia; Caboclo, Luis Otavio; Centeno, Ricardo Silva; Sakamoto, Americo Ceiki; Yacubian, Elza Marcia Targas

    2007-01-01

    Objective: To determine the frequency and regional involvement of temporal pole signal abnormality (TPA) in patients with hippocampal sclerosis (HS) using fluid-attenuated inversion-recovery (FLAIR) MR imaging, and to correlate this feature with history. Method: Coronal FLAIR images of the temporal pole were assessed in 120 patients with HS and in 30 normal subjects, to evaluate gray-white matter demarcation. Results: Ninety (75%) of 120 patients had associated TPA. The HS side made difference regarding the presence of TPA, with a left side prevalence (p=0.04, χ 2 test). The anteromedial zone of temporal pole was affected in 27 (30%) out of 90 patients. In 63 (70%) patients the lateral zone were also affected. Patients with TPA were younger at seizure onset (p=0.018), but without association with duration of epilepsy. Conclusion: Our FLAIR study show temporal pole signal abnormality in 3/4 of patients with HS, mainly seen on the anteromedial region, with a larger prevalence when the left hippocampus was involved. (author)

  14. Ultra-low energy storage ring at FLAIR

    International Nuclear Information System (INIS)

    Welsch, Carsten P.; Papash, A. I.; Gorda, O.; Harasimowicz, J.; Karamyshev, O.; Karamysheva, G.; Newton, D.; Panniello, M.; Putignano, M.; Siggel-King, M. R. F.; Smirnov, A.

    2012-01-01

    The Ultra-low energy electrostatic Storage Ring (USR) at the future Facility for Low-energy Antiproton and Ion Research (FLAIR) will provide cooled beams of antiprotons in the energy range between 300 keV down to 20 keV and possibly less. The USR has been completely redesigned over the past three years. The ring structure is based on a “split achromat” lattice that allows in-ring experiments with internal gas jet target. Beam parameters might be adjusted in a wide range: from very short pulses in the nanosecond regime to a Coasting beam. In addition, a combined fast and slow extraction scheme was developed that allows for providing external experiments with cooled beams of different time structure. Detailed investigations of the USR, including studies into the ring’s long term beam dynamics, life time, equilibrium momentum spread and equilibrium lateral spread during collisions with an internal target were carried out. New tools and beam handling techniques for diagnostics of ultra-low energy ions at beam intensities less than 10 6 were developed by the QUASAR Group. In this paper, progress on the USR project will be presented with an emphasis on the expected beam parameters available to the experiments at FLAIR.

  15. Comparison of T2 and FLAIR imaging for target delineation in high grade gliomas

    Directory of Open Access Journals (Sweden)

    Miller Robert W

    2010-01-01

    Full Text Available Abstract Background FLAIR and T2 weighted MRIs are used based on institutional preference to delineate high grade gliomas and surrounding edema for radiation treatment planning. Although these sequences have inherent physical differences there is limited data on the clinical and dosimetric impact of using either or both sequences. Methods 40 patients with high grade gliomas consecutively treated between 2002 and 2008 of which 32 had pretreatment MRIs with T1, T2 and FLAIR available for review were selected for this study. These MRIs were fused with the treatment planning CT. Normal structures, clinical tumor volume (CTV and planning tumor volume (PTV were then defined on the T2 and FLAIR sequences. A Venn diagram analysis was performed for each pair of tumor volumes as well as a fractional component analysis to assess the contribution of each sequence to the union volume. For each patient the tumor volumes were compared in terms of total volume in cubic centimeters as well as anatomic location using a discordance index. The overlap of the tumor volumes with critical structures was calculated as a measure of predicted toxicity. For patients with MRI documented failures, the tumor volumes obtained using the different sequences were compared with the recurrent gross tumor volume (rGTV. Results The FLAIR CTVs and PTVs were significantly larger than the T2 CTVs and PTVs (p Conclusions Although both T2 and FLAIR MRI sequences are used to define high grade glial neoplasm and surrounding edema, our results show that the volumes generated using these techniques are different and not interchangeable. These differences have bearing on the use of intensity modulated radiation therapy (IMRT and highly conformal treatment as well as on future clinical trials where the bias of using one technique over the other may influence the study outcome.

  16. Perbedaan Intensitas Penyengatan Meningeal Hasil MRI antara Sekuens T2 FLAIR Post Contrast dan T1WI Post Contrast Gadolinium-DTPA dalam Mendeteksi Penyangatan Meningeal pada Kasus Meningitis Tuberkulosis

    Directory of Open Access Journals (Sweden)

    Arie Hendarin

    2017-09-01

    Full Text Available Diagnosis meningitis TB terutama pada kasus possible dan probable sulit ditegakkan. Pemeriksaan MRI kepala dengan kontras Gadolinium-DTPA adalah modalitas radiologi yang paling sensitif untuk membantu mendiagnosis penyakit ini. Penyangatan meningeal di daerah basal merupakan gambaran MRI yang paling banyak ditemukan pada meningitis TB. Tujuan penelitian ini adalah mengetahui perbedaan peningkatan intensitas sinyal meningen sekuens T2-FLAIR dengan T1WI pada pasien meningitis tuberkulosis menggunakan pemeriksaan MRI kepala dengan kontras Gadolinium-DTPA di RSUP Dr. Hasan Sadikin Bandung pada bulan Januari 2015–Juni 2016. Subjek penelitian sebanyak 21 orang dengan meningitis TB dilakukan pemeriksaan MRI kepala dengan kontras Gadolinium-DTPA. Analisis statistik komparatif dilakukan untuk menguji perbedaan peningkatan intensitas sinyal meningen sekuens T2-FLAIR post contrast dengan T1WI post contrast. Hasil penelitian menujukkan rerata peningkatan intensitas sinyal meningen sekuen T2-FLAIR (∆T2-FLAIR sebesar 360,59±182,19 aμ sedangkan T1WI (∆T1WI sebesar 126,47±72,57 aμ. Hasil uji statistik menggunakan uji T pada derajat kepercayaan 95% menunjukkan perbedaan yang bermakna ∆T2-FLAIR dengan ∆T1WI pada nilai p=0,000. Sebagai simpulan didapatkan peningkatan intensitas sinyal meningen sekuens T2-FLAIR post contrast lebih besar daripada T1WI post contrast pada kasus meningitis TB.  [MKB. 2017;49(3:172–78] Kata kunci: Meningitis tuberkulosis, MRI sekuens T1WI dan T2-FLAIR, penyangatan meningeal Difference between Gadolinium-DTPA Enhanced T2 FLAIR Sequence and T1WI Sequence MRI in Detecting Meningeal Enhancement in Tuberculous Meningitis The diagnosis of TB meningitis, especially in possible and probable cases, is difficult. Contrast-enhanced MRI of the head with Gadolinium-DTPA is the most sensitive imaging modality that supports diagnosis of this disease. The most common presentation of TB meningitis in MRI is basal meningeal enhancement

  17. Detection of optic nerve atrophy following a single episode of unilateral optic neuritis by MRI using a fat-saturated short-echo fast FLAIR sequence

    International Nuclear Information System (INIS)

    Hickman, S.J.; Brex, P.A.; Silver, N.C.; Barker, G.J.; Miller, D.H.; Brierley, C.M.H.; Compston, D.A.S.; Scolding, N.J.; Moseley, I.F.; Plant, G.T.

    2001-01-01

    We describe an MRI technique for quantifying optic nerve atrophy resulting from a single episode of unilateral optic neuritis. We imaged 17 patients, with a median time since onset of optic neuritis of 21 months (range 3-81 months), using a coronal-oblique fat-saturated short-echo fast fluid-attenuated inversion-recovery (sTE fFLAIR) sequence. The mean cross-sectional area of the intraorbital portion of the optic nerves was calculated by a blinded observer from five consecutive 3 mm slices from the orbital apex forwards using a semiautomated contouring technique and compared with data from 16 controls. The mean optic nerve area was 11.2mm 2 in the affected eye of the patients, 12.9mm 2 in the contralateral eye (P = 0.006 compared to the affected eye) and 12.8mm 2 in controls (P = 0.03 compared to the affected eyes). There was a significant negative correlation between disease duration and the size of the affected optic nerve (r = -0.59, P = 0.012). The measurement coefficient of variation was 4.8 %. The sTE fFLAIR sequence enables measurement of optic nerve area with sufficient reproducibility to show optic nerve atrophy following a single episode of unilateral optic neuritis. The correlation of increasing optic nerve atrophy with disease duration would be consistent with ongoing axonal loss in a persistently demyelinated lesion, or Wallerian degeneration following axonal damage during the acute inflammatory phase. (orig.)

  18. Ivy Sign on Fluid-Attenuated Inversion Recovery Images in Moyamoya Disease: Correlation with Clinical Severity and Old Brain Lesions

    OpenAIRE

    Seo, Kwon-Duk; Suh, Sang Hyun; Kim, Yong Bae; Kim, Ji Hwa; Ahn, Sung Jun; Kim, Dong-Seok; Lee, Kyung-Yul

    2015-01-01

    Purpose Leptomeningeal collateral, in moyamoya disease (MMD), appears as an ivy sign on fluid-attenuated inversion-recovery (FLAIR) images. There has been little investigation into the relationship between presentation of ivy signs and old brain lesions. We aimed to evaluate clinical significance of ivy signs and whether they correlate with old brain lesions and the severity of clinical symptoms in patients with MMD. Materials and Methods FLAIR images of 83 patients were reviewed. Each cerebr...

  19. The effect of magnetisation transfer contrast on cerebrospinal fluid on motion artefacts on fluid-attenuated inversion-recovery images

    International Nuclear Information System (INIS)

    Aprile, I.; Principi, M.; Ottaviano, P.; Scapeccia, M.

    2003-01-01

    We assessed possible advantages of the use of fluid-attenuated inversion-recovery (FLAIR) sequences with magnetisation-transfer contrast (MTC) over conventional FLAIR images. We carried out cranial MRI at 1 tesla on 50 patients with both sequences. In nine patients with multiple sclerosis (MS) we performed a quantitative comparison of the two sequences, looking at the contrast-to-noise ratio between lesions and normal white matter and counting the number of lesions shown using each method. A qualitative comparison on all patients consisted of the analysis of the appearance of the normal parenchyma, of any lesions, and of artefacts, with particular reference to cerebrospinal fluid (CSF) motion artefacts. The quantitative analysis showed no meaningful difference between the two sequences. The cerebral parenchyma and lesions appeared substantially the same with both techniques. With FLAIR MTC there was a clear, and consistent reduction in CSF motion artefacts. FLAIR MTC sequences can usefully be used in place of the conventional sequence at 1 tesla. (orig.)

  20. Abnormal hyperintensity within the subarachnoid space evaluated by fluid-attenuated inversion-recovery MR imaging: a spectrum of central nervous system diseases

    International Nuclear Information System (INIS)

    Maeda, M.; Sakuma, H.; Takeda, K.; Yagishita, A.; Yamamoto, T.

    2003-01-01

    A variety of central nervous system (CNS) diseases are associated with abnormal hyperintensity within the subarachnoid space (SAS) by fluid-attenuated inversion-recovery (FLAIR) MR imaging. Careful attention to the SAS can provide additional useful information that may not be available with conventional MR sequences. The purpose of this article is to provide a pictorial essay about CNS diseases and FLAIR images with abnormal hyperintensity within the SAS. We present several CNS diseases including subarachnoid hemorrhage, meningitis, leptomeningeal metastases, acute infarction, and severe arterial occlusive diseases such as moya-moya disease. We also review miscellaneous diseases or normal conditions that may exhibit cerebrospinal fluid hyperintensity on FLAIR images. Although the detection of abnormal hyperintensity suggests the underlying CNS diseases and narrows differential diagnoses, FLAIR imaging sometimes presents artifactual hyperintensity within the SAS that can cause the misinterpretation of normal SAS as pathologic conditions; therefore, radiologists should be familiar with such artifactual conditions as well as pathologic conditions shown as hyperintensity by FLAIR images. This knowledge is helpful in establishing the correct diagnosis. (orig.)

  1. MRI in differentiation between recurrent disk herniation and postoperative scar. Value of FLAIR sequences

    International Nuclear Information System (INIS)

    Capiel, Carlos A. h; Bouzas, Carlos A.; Porto, Viviana G.

    2000-01-01

    The differential diagnosis between epidural fibrosis and recurrent or residual disk herniation in symptomatic patients who have been operated is often difficult. The MRI with Spin Echo T1 sequences before and after i.v. gadolinium plays and important role in the differentiation of these two entities. The signal characteristics in T1 and T2 sequences are not reliable to distinguish between herniated disk and scar. In order to evaluate the use of the FLAIR technique in the differentiation between herniated disk and epidural fibrosis we used MRI to study 37 symptomatic patients who had been operated of lumbar disk herniation, with FSE-T2 sequences in axial and sagittal planes, FLAIR in axial sections and SE-T1 in sagittal and axial sections before and after i.v. gadolinium. This sequence was used as gold standard for the final diagnosis. We conclude that the FLAIR technique is a reliable alternative in the differential diagnosis between epidural fibrosis and herniated disk, providing a positive correlation to the SE-T1-weighted images with i.v. gadolinium in 100% of the patients. (author)

  2. Lateralization of temporal lobe epilepsy using a novel uncertainty analysis of MR diffusion in hippocampus, cingulum, and fornix, and hippocampal volume and FLAIR intensity.

    Science.gov (United States)

    Nazem-Zadeh, Mohammad-Reza; Schwalb, Jason M; Elisevich, Kost V; Bagher-Ebadian, Hassan; Hamidian, Hajar; Akhondi-Asl, Ali-Reza; Jafari-Khouzani, Kourosh; Soltanian-Zadeh, Hamid

    2014-07-15

    To analyze the utility of a quantitative uncertainty analysis approach for evaluation and comparison of various MRI findings for the lateralization of epileptogenicity in mesial temporal lobe epilepsy (mTLE), including novel diffusion-based analyses. We estimated the hemispheric variation uncertainty (HVU) of hippocampal T1 volumetry and FLAIR (Fluid Attenuated Inversion Recovery) intensity. Using diffusion tensor images of 23 nonepileptic subjects, we estimated the HVU levels of mean diffusivity (MD) in the hippocampus, and fractional anisotropy (FA) in the posteroinferior cingulum and crus of fornix. Imaging from a retrospective cohort of 20 TLE patients who had undergone surgical resection with Engel class I outcomes was analyzed to determine whether asymmetry of preoperative volumetrics, FLAIR intensities, and MD values in hippocampi, as well as FA values in posteroinferior cingula and fornix crura correctly predicted laterality of seizure onset. Ten of the cohort had pathologically proven mesial temporal sclerosis (MTS). Seven of these patients had undergone extraoperative electrocorticography (ECoG) for lateralization or to rule out extra-temporal foci. HVU was estimated to be 3.1×10(-5) for hippocampal MD, 0.027 for FA in posteroinferior cingulum, 0.018 for FA in crus of fornix, 0.069 for hippocampal normalized volume, and 0.099 for hippocampal normalized FLAIR intensity. Using HVU analysis, a higher hippocampal MD value, lower FA within the posteroinferior cingulum and crus of fornix, shrinkage in hippocampal volume, and higher hippocampal FLAIR intensity were observed beyond uncertainty on the side ipsilateral to seizure onset for 10, 10, 9, 9, and 10 out of 10 pathology-proven MTS patients, respectively. Considering all 20 TLE patients, these numbers were 18, 15, 14, 13, and 16, respectively. However, consolidating the lateralization results of HVU analysis on these quantities by majority voting has detected the epileptogenic side for 19 out of 20 cases

  3. A comparison of lesion detection and conspicuity on T2-weighted images (T2 FFE), FLAIR and diffusion-weighted images in patients with traumatic brain injury

    International Nuclear Information System (INIS)

    Kwon, Eun Yong; Lee, Myeong sub; Kim, Myung Soon; Hong, In Soo; Kim, Young Ju; Whang, Gum

    2001-01-01

    To compare the lesion detectability and conspicuity in traumatic brain injury on T-2 FFE, FLAIR and diffusion weighted imaging (DWI) sequences. Thirty-three patients who underwent MR brain imaging after traumatic brain injury were reviewed. T-2 FFE, FLAIR and diffusion-weighted MR sequences were obtained and were compared in terms of the detectability and conspicuity of intra- and extra-axial lesions which showed abnormal signal intensities. Among 33 patients, a total of 108 lesions were found, T-2 FFE sequences detected 88(81%) of these, FLAIR sequences 91%(84%), and diffusion-weighted sequences 57(52%). In the case of petechial hemorrhagic lesions, 16 were detected by T-2 FFE imaging but only one by FLAIR and one by DWI. Sixteen extra-axial lesions (73%) were detected by T-2 FFE, 21 (95%) by FLAIR, and 11(50%) by DWI. Lesion conspicuity on FLAIR images was judged superior to that on T-2 FFE and diffusion-weighted images in 42 lesions (75%). Eleven extra-axial Lesions (92%) were more conspicuous on FLAIR than on T-2 FFE and DWI. For detecting traumatic brain lesions and determining their conspicuity, FLAIR imaging was more useful than T-2 FFE and diffusion weighting , while T-2 FFE imaging was more sensitive for the detecion of petechial hemorrhage. Although diffusion-weighted imaging was generally inferior to both FLAIR and T-2 FFE in terms of lesion detection and conspicuity, for some lesions it was superior. The results suggest that images obtained at each pulse sequence can be used as complementary imaging sequences, and that in traumatic brain injury, the acquisition of FLAIR, T-2 FFE and diffusion-weighted images is useful

  4. Discrete Fracture Modeling of 3D Heterogeneous Enhanced Coalbed Methane Recovery with Prismatic Meshing

    Directory of Open Access Journals (Sweden)

    Yongbin Zhang

    2015-06-01

    Full Text Available In this study, a 3D multicomponent multiphase simulator with a new fracture characterization technique is developed to simulate the enhanced recovery of coalbed methane. In this new model, the diffusion source from the matrix is calculated using the traditional dual-continuum approach, while in the Darcy flow scale, the Discrete Fracture Model (DFM is introduced to explicitly represent the flow interaction between cleats and large-scale fractures. For this purpose, a general formulation is proposed to model the multicomponent multiphase flow through the fractured coal media. The S&D model and a revised P&M model are incorporated to represent the geomechanical effects. Then a finite volume based discretization and solution strategies are constructed to solve the general ECBM equations. The prismatic meshing algorism is used to construct the grids for 3D reservoirs with complex fracture geometry. The simulator is validated with a benchmark case in which the results show close agreement with GEM. Finally, simulation of a synthetic heterogeneous 3D coal reservoir modified from a published literature is performed to evaluate the production performance and the effects of injected gas composition, well pattern and gas buoyancy.

  5. Incidental pineal cysts in children who undergo 3-T MRI

    International Nuclear Information System (INIS)

    Whitehead, Matthew T.; Oh, Christopher C.; Choudhri, Asim F.

    2013-01-01

    Pineal cysts, both simple and complex, are commonly encountered in children. More cysts are being detected with MR technology; however, nearly all pineal cysts are benign and require no follow-up. To discover the prevalence of pineal cysts in children at our institution who have undergone high-resolution 3-T MRI. We retrospectively reviewed 100 consecutive 3-T brain MRIs in children ages 1 month to 17 years (mean 6.8 ± 5.1 years). We evaluated 3-D volumetric T1-W imaging, axial T2-W imaging, axial T2-W FLAIR (fluid attenuated inversion recovery) and coronal STIR (short tau inversion recovery) sequences. Pineal parenchymal and cyst volumes were measured in three planes. Cysts were analyzed for the presence and degree of complexity. Pineal cysts were present in 57% of children, with a mean maximum linear dimension of 4.2 mm (range 1.5-16 mm). Of these cysts, 24.6% showed thin septations or fluid levels reflecting complexity. None of the cysts demonstrated complete T2/FLAIR signal suppression. No cyst wall thickening or nodularity was present. There was no significant difference between the ages of children with and without cysts. Cysts were more commonly encountered in girls than boys (67% vs. 52%; P = 0.043). There was a slight trend toward increasing pineal gland volume with age. Pineal cysts are often present in children and can be incidentally detected by 3-T MRI. Characteristic-appearing pineal cysts in children are benign, incidental findings, for which follow-up is not required if there are no referable symptoms or excessive size. (orig.)

  6. T1-weighted fluid-attenuated inversion recovery and T1-weighted fast spin-echo contrast-enhanced imaging: a comparison in 20 patients with brain lesions

    International Nuclear Information System (INIS)

    Al-Saeed, O.; Athyal, R. P.; Ismail, M.; Rudwan, M.; Khafajee, S.

    2009-01-01

    Full text: Tl-weighted fluid-attenuated inversion recovery (FLAIR) sequence is a relatively new pulse sequence for intracranial MR imaging. This study was performed to compare the image quality of Tl-weighted FLAIR with the Tl-weighted FSE sequence. Twenty patients with brain lesions underwent Tl-weighted fast spin-echo (FSE) and Tl-weighted FLAIR during the same imaging session. Four quantitative and three qualitative criteria were used to compare the two sequences after contrast. Two of four quantitative criteria pertained to lesion characteristics: lesion to white matter (WM) contrast-to-noise ratio (CNR) and lesion to cerebrospinal fluid (CSF) CNR, and two related to signals from normal tissue: grey matter to WM CNR and WM to CSF CNR. The three qualitative criteria were conspicuousness of the lesion, the presence of image artefacts and the overall image contrast. Both Tl-weighted FSE and FLAIR images were effective in demonstrating lesions. Image contrast was superior in Tl-weighted FLAIR images with significantly improved grey matter-WM CNRs and CSF-WM CNRs. The overall image contrast was judged to be superior on Tl-weighted FLAIR images compared with Tl-weighted FSE images by all neuroradiologists. Two of three reviewers considered that the FLAIR images had slightly increased imaging artefacts that, however, did not interfere with image interpretation. Tl-weighted FLAIR imaging provides improved lesion-to-background and grey to WM contrast-to-noise ratios. Superior conspicuity of lesions and overall image contrast is obtained in comparable acquisition times. These indicate an important role for Tl-weighted FLAIR in intracranial imaging and highlight its advantage over the more widely practiced Tl-weighted FSE sequence

  7. Detection of brain metastasis. Comparison of Turbo-FLAIR imaging, T2-weighted imaging and double-dose gadolinium-enhanced MR imaging

    International Nuclear Information System (INIS)

    Okubo, Toshiyuki; Hayashi, Naoto; Shirouzu, Ichiro; Abe, Osamu; Ohtomo, Kuni; Sasaki, Yasuhito; Aoki, Shigeki; Wada, Akihiko

    1998-01-01

    The purpose of this study was to compare Turbo-FLAIR imaging, T 2 -weighted imaging, and double-dose gadolinium-enhanced MR imaging in the detection of brain metastasis. Using the three sequences, 20 consecutive patients with brain metastases were prospectively studied with a 1.5-Tesla system. Three independent, blinded readers assessed the images for the presence, size, number, and location of metastatic lesions. In the detection of large lesions (>0.5 cm), Turbo-FLAIR imaging (38/48, 79%) was not significantly different from gadolinium-enhanced imaging (42/48, 88%) (p=0.273). T 2 -weighted imaging (31/48, 65%), however, was inferior to gadolinium-enhanced imaging (p<0.05). There was no difference between Turbo-FLAIR imaging and gadolinium-enhanced imaging in the accuracy of detecting solitary brain metastasis (4/4, 100%). In conclusion, Turbo-FLAIR imaging is a useful, noninvasive screening modality for brain metastasis. Its use may lead to cost savings in the diagnosis of brain metastases and may impact positively the cost-effectiveness of treatment. (author)

  8. Brain tumor locating in 3D MR volume using symmetry

    Science.gov (United States)

    Dvorak, Pavel; Bartusek, Karel

    2014-03-01

    This work deals with the automatic determination of a brain tumor location in 3D magnetic resonance volumes. The aim of this work is not the precise segmentation of the tumor and its parts but only the detection of its location. This work is the first step in the tumor segmentation process, an important topic in neuro-image processing. The algorithm expects 3D magnetic resonance volumes of brain containing a tumor. The detection is based on locating the area that breaks the left-right symmetry of the brain. This is done by multi-resolution comparing of corresponding regions in left and right hemisphere. The output of the computation is the probabilistic map of the tumor location. The created algorithm was tested on 80 volumes from publicly available BRATS databases containing 3D brain volumes afflicted by a brain tumor. These pathological structures had various sizes and shapes and were located in various parts of the brain. The locating performance of the algorithm was 85% for T1-weighted volumes, 91% for T1-weighted contrast enhanced volumes, 96% for FLAIR and T2-wieghted volumes and 95% for their combinations.

  9. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Koichi, E-mail: k-takano@fukuoka-u.ac.jp; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-15

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  10. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    International Nuclear Information System (INIS)

    Takano, Koichi; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-01

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  11. 4-D tomographic monitoring of enhanced oil recovery

    International Nuclear Information System (INIS)

    Brzostowski, M.A.; McMechan, G.A.

    1991-01-01

    One application of tomography that has recently received considerable attention is reservoir monitoring for Enhanced Oil Recovery (EOR). Tomographic monitoring of a moving steam front uses the significant decrease in compressional wave velocity that occurs as hydrocarbon temperature increases. The purposes of this paper are to present a working algorithm for 3-D tomography, to demonstrate the feasibility of 3-D imaging of a simulated reservoir in which the position of a steam front changes with time, and to illustrate the relations between survey geometry and the resolution of the target

  12. Multimodal MEMPRAGE, FLAIR, and R2* Segmentation to Resolve Dura and Vessels from Cortical Gray Matter

    Directory of Open Access Journals (Sweden)

    Roberto Viviani

    2017-05-01

    Full Text Available While widely in use in automated segmentation approaches for the detection of group differences or of changes associated with continuous predictors in gray matter volume, T1-weighted images are known to represent dura and cortical vessels with signal intensities similar to those of gray matter. By considering multiple signal sources at once, multimodal segmentation approaches may be able to resolve these different tissue classes and address this potential confound. We explored here the simultaneous use of FLAIR and apparent transverse relaxation rates (a signal related to T2* relaxation maps and having similar contrast with T1-weighted images. Relative to T1-weighted images alone, multimodal segmentation had marked positive effects on 1. the separation of gray matter from dura, 2. the exclusion of vessels from the gray matter compartment, and 3. the contrast with extracerebral connective tissue. While obtainable together with the T1-weighted images without increasing scanning times, apparent transverse relaxation rates were less effective than added FLAIR images in providing the above mentioned advantages. FLAIR images also improved the detection of cortical matter in areas prone to susceptibility artifacts in standard MPRAGE T1-weighted images, while the addition of transverse relaxation maps exacerbated the effect of these artifacts on segmentation. Our results confirm that standard MPRAGE segmentation may overestimate gray matter volume by wrongly assigning vessels and dura to this compartment and show that multimodal approaches may greatly improve the specificity of cortical segmentation. Since multimodal segmentation is easily implemented, these benefits are immediately available to studies focusing on translational applications of structural imaging.

  13. FLAIR vascular hyperintensities and 4D MR angiograms for the estimation of collateral blood flow in anterior cerebral artery ischemia.

    Directory of Open Access Journals (Sweden)

    Matthias Gawlitza

    Full Text Available To assess FLAIR vascular hyperintensities (FVH and dynamic (4D angiograms derived from perfusion raw data as proposed magnetic resonance (MR imaging markers of leptomeningeal collateral circulation in patients with ischemia in the territory of the anterior cerebral artery (ACA.Forty patients from two tertiary care university hospitals were included. Infarct volumes and perfusion deficits were manually measured on DWI images and TTP maps, respectively. FVH and collateral flow on 4D MR angiograms were assessed and graded as previously specified.Forty-one hemispheres were affected. Mean DWI lesion volume was 8.2 (± 13.9; range 0-76.9 ml, mean TTP lesion volume was 24.5 (± 17.2, range 0-76.7 ml. FVH were observed in 26/41 (63.4% hemispheres. Significant correlations were detected between FVH and TTP lesion volume (ρ = 0.4; P<0.01 absolute (ρ = 0.37; P<0.05 and relative mismatch volume (ρ = 0.35; P<0.05. The modified ASITN/SIR score correlated inversely with DWI lesion volume (ρ = -0.58; P<0.01 and positively with relative mismatch (ρ = 0.29; P< 0.05. ANOVA of the ASITN/SIR score revealed significant inter-group differences for DWI (P<0.001 and TTP lesion volumes (P<0.05. No correlation was observed between FVH scores and modified ASITH/SIR scores (ρ = -0.16; P = 0.32.FVH and flow patterns on 4D MR angiograms are markers of perfusion deficits and tissue at risk. As both methods did not show a correlation between each other, they seem to provide complimentary instead of redundant information. Previously shown evidence for the meaning of these specific MR signs in internal carotid and middle cerebral artery stroke seems to be transferrable to ischemic stroke in the ACA territory.

  14. Flair: A powerful but user friendly graphical interface for FLUKA

    International Nuclear Information System (INIS)

    Vlachoudis, V.

    2009-01-01

    FLAIR is an advanced user graphical interface for FLUKA, to enable the user to start and control FLUKA jobs completely from a GUI environment without the need for command-line interactions. It is written entirely with python and Tkinter allowing easier portability across various operating systems and great programming flexibility with focus to be used as an Application Programming Interface (API) for FLUKA. FLAIR is an integrated development environment (IDE) for FLUKA, it does not only provide means for the post processing of the output but a big emphasis has been set on the creation and checking of error free input files. It contains a fully featured editor for editing the input files in a human readable way with syntax highlighting, without hiding the inner functionality of FLUKA from the users. It provides also means for building the executable, debugging the geometry, running the code, monitoring the status of one or many runs, inspection of the output files, post processing of the binary files (data merging) and interface to plotting utilities like gnuplot and PovRay for high quality plots or photo-realistic images. The program includes also a database of selected properties of all known nuclides and their known isotopic composition as well a reference database of ∼ 300 predefined materials together with their Sterheimer parameters. (authors)

  15. Magnetic resonance imaging protocols for examination of the neurocranium at 3 T.

    Science.gov (United States)

    Schwindt, W; Kugel, H; Bachmann, R; Kloska, S; Allkemper, T; Maintz, D; Pfleiderer, B; Tombach, B; Heindel, W

    2003-09-01

    The increasing availability of high-field (3 T) MR scanners requires adapting and optimizing clinical imaging protocols to exploit the theoretically higher signal-to-noise ratio (SNR) of the higher field strength. Our aim was to establish reliable and stable protocols meeting the clinical demands for imaging the neurocranium at 3 T. Two hundred patients with a broad range of indications received an examination of the neurocranium with an appropriate assortment of imaging techniques at 3 T. Several imaging parameters were optimized. Keeping scan times comparable to those at 1.5 T we increased spatial resolution. Contrast-enhanced and non-enhanced T1-weighted imaging was best applying gradient-echo and inversion recovery (rather than spin-echo) techniques, respectively. For fluid-attenuated inversion recovery (FLAIR) imaging a TE of 120 ms yielded optimum contrast-to-noise ratio (CNR). High-resolution isotropic 3D data sets were acquired within reasonable scan times. Some artifacts were pronounced, but generally imaging profited from the higher SNR. We present a set of optimized examination protocols for neuroimaging at 3 T, which proved to be reliable in a clinical routine setting.

  16. Magnetic resonance imaging protocols for examination of the neurocranium at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Schwindt, W.; Kugel, H.; Bachmann, R.; Kloska, S.; Allkemper, T.; Maintz, D.; Pfleiderer, B.; Tombach, B.; Heindel, W. [Institut fuer Klinische Radiologie, Universitaetsklinikum Muenster, Albert-Schweitzer-Strasse 33, 48129, Muenster (Germany)

    2003-09-01

    The increasing availability of high-field (3 T) MR scanners requires adapting and optimizing clinical imaging protocols to exploit the theoretically higher signal-to-noise ratio (SNR) of the higher field strength. Our aim was to establish reliable and stable protocols meeting the clinical demands for imaging the neurocranium at 3 T. Two hundred patients with a broad range of indications received an examination of the neurocranium with an appropriate assortment of imaging techniques at 3 T. Several imaging parameters were optimized. Keeping scan times comparable to those at 1.5 T we increased spatial resolution. Contrast-enhanced and non-enhanced T1-weighted imaging was best applying gradient-echo and inversion recovery (rather than spin-echo) techniques, respectively. For fluid-attenuated inversion recovery (FLAIR) imaging a TE of 120 ms yielded optimum contrast-to-noise ratio (CNR). High-resolution isotropic 3D data sets were acquired within reasonable scan times. Some artifacts were pronounced, but generally imaging profited from the higher SNR. We present a set of optimized examination protocols for neuroimaging at 3 T, which proved to be reliable in a clinical routine setting. (orig.)

  17. Magnetic resonance imaging protocols for examination of the neurocranium at 3 T

    International Nuclear Information System (INIS)

    Schwindt, W.; Kugel, H.; Bachmann, R.; Kloska, S.; Allkemper, T.; Maintz, D.; Pfleiderer, B.; Tombach, B.; Heindel, W.

    2003-01-01

    The increasing availability of high-field (3 T) MR scanners requires adapting and optimizing clinical imaging protocols to exploit the theoretically higher signal-to-noise ratio (SNR) of the higher field strength. Our aim was to establish reliable and stable protocols meeting the clinical demands for imaging the neurocranium at 3 T. Two hundred patients with a broad range of indications received an examination of the neurocranium with an appropriate assortment of imaging techniques at 3 T. Several imaging parameters were optimized. Keeping scan times comparable to those at 1.5 T we increased spatial resolution. Contrast-enhanced and non-enhanced T1-weighted imaging was best applying gradient-echo and inversion recovery (rather than spin-echo) techniques, respectively. For fluid-attenuated inversion recovery (FLAIR) imaging a TE of 120 ms yielded optimum contrast-to-noise ratio (CNR). High-resolution isotropic 3D data sets were acquired within reasonable scan times. Some artifacts were pronounced, but generally imaging profited from the higher SNR. We present a set of optimized examination protocols for neuroimaging at 3 T, which proved to be reliable in a clinical routine setting. (orig.)

  18. Rationality, Intuition and Flair in Entrepreneur’s Configuration - an Epistemological Approach

    OpenAIRE

    Zoltan Raluca; Vancea Romulus

    2011-01-01

    The present paper proposes an overview of the evolution of the concept of entrepreneur in an epistemological approach. After a brief history of the concept, there are some basic economic and managerial guidelines in entrepreneur’s configuration; these guidelines are found in the work of experts in management, respectively, leading economists. Rationality, flair and intuition of the entrepreneur are then analyzed in terms of existing trends in the economy, acknowledging the entrepreneurship an...

  19. Qualitative and quantitative comparison of contrast-enhanced fluid-attenuated inversion recovery, magnetization transfer spin echo, and fat-saturation T1-weighted sequences in infectious meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Azad, Rajiv; Tayal, Mohit; Azad, Sheenam; Sharma, Garima; Srivastava, Rajendra Kumar [SGRR Institute of Medical and Health Sciences, Patel Nagar, Dehradun (India)

    2017-11-15

    To compare the contrast-enhanced fluid-attenuated inversion recovery (CE-FLAIR), the CE T1-weighted (CE-T1W) sequence with fat suppression (FS) and magnetization transfer (MT) for early detection and characterization of infectious meningitis. Fifty patients and 10 control subjects were evaluated with the CE-FLAIR and the CE-T1W sequences with FS and MT. Qualitative assessment was done by two observers for presence and grading of abnormal leptomeningeal enhancement. Quantitative assessment included computation of net meningeal enhancement, using single pixel signal intensity software. A newly devised FLAIR based scoring system, based on certain imaging features including ventricular dilatation, ependymal enhancement, infarcts and subdural effusions was used to indicate the etiology. Data were analysed using the Student's t test, Cohen's Kappa coefficient, Pearson's correlation coefficient, the intraclass correlation coefficient, one way analysis of variance, and Fisher's exact test with Bonferroni correction as the post hoc test. The CE-FLAIR sequence demonstrated a better sensitivity (100%), diagnostic accuracy (95%), and a stronger correlation with the cerebrospinal fluid, total leukocyte count (r = 0.75), protein (r = 0.77), adenosine deaminase (r = 0.81) and blood glucose (r = -0.6) values compared to the CE-T1W sequences. Qualitative grades and quantitative meningeal enhancement on the CE-FLAIR sequence were also significantly greater than those on the other sequences. The FLAIR based scoring system yielded a diagnostic accuracy of 91.6% and a sensitivity of 96%. A strong inverse Pearson's correlation (r = -0.95) was found between the assigned score and patient's Glasgow Coma Scale at the time of admission. The CE-FLAIR sequence is better suited for evaluating infectious meningitis and could be included as a part of the routine MR imaging protocol.

  20. Qualitative and quantitative comparison of contrast-enhanced fluid-attenuated inversion recovery, magnetization transfer spin echo, and fat-saturation T1-weighted sequences in infectious meningitis

    International Nuclear Information System (INIS)

    Azad, Rajiv; Tayal, Mohit; Azad, Sheenam; Sharma, Garima; Srivastava, Rajendra Kumar

    2017-01-01

    To compare the contrast-enhanced fluid-attenuated inversion recovery (CE-FLAIR), the CE T1-weighted (CE-T1W) sequence with fat suppression (FS) and magnetization transfer (MT) for early detection and characterization of infectious meningitis. Fifty patients and 10 control subjects were evaluated with the CE-FLAIR and the CE-T1W sequences with FS and MT. Qualitative assessment was done by two observers for presence and grading of abnormal leptomeningeal enhancement. Quantitative assessment included computation of net meningeal enhancement, using single pixel signal intensity software. A newly devised FLAIR based scoring system, based on certain imaging features including ventricular dilatation, ependymal enhancement, infarcts and subdural effusions was used to indicate the etiology. Data were analysed using the Student's t test, Cohen's Kappa coefficient, Pearson's correlation coefficient, the intraclass correlation coefficient, one way analysis of variance, and Fisher's exact test with Bonferroni correction as the post hoc test. The CE-FLAIR sequence demonstrated a better sensitivity (100%), diagnostic accuracy (95%), and a stronger correlation with the cerebrospinal fluid, total leukocyte count (r = 0.75), protein (r = 0.77), adenosine deaminase (r = 0.81) and blood glucose (r = -0.6) values compared to the CE-T1W sequences. Qualitative grades and quantitative meningeal enhancement on the CE-FLAIR sequence were also significantly greater than those on the other sequences. The FLAIR based scoring system yielded a diagnostic accuracy of 91.6% and a sensitivity of 96%. A strong inverse Pearson's correlation (r = -0.95) was found between the assigned score and patient's Glasgow Coma Scale at the time of admission. The CE-FLAIR sequence is better suited for evaluating infectious meningitis and could be included as a part of the routine MR imaging protocol

  1. Application of variable threshold intensity to segmentation for white matter hyperintensities in fluid attenuated inversion recovery magnetic resonance images

    International Nuclear Information System (INIS)

    Yoo, Byung Il; Han, Ji Won; Oh, San Yeo Wool; Kim, Tae Hui; Lee, Jung Jae; Lee, Eun Young; MacFall, James R.; Payne, Martha E.; Kim, Jae Hyoung; Kim, Ki Woong

    2014-01-01

    White matter hyperintensities (WMHs) are regions of abnormally high intensity on T2-weighted or fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI). Accurate and reproducible automatic segmentation of WMHs is important since WMHs are often seen in the elderly and are associated with various geriatric and psychiatric disorders. We developed a fully automated monospectral segmentation method for WMHs using FLAIR MRIs. Through this method, we introduce an optimal threshold intensity (I O ) for segmenting WMHs, which varies with WMHs volume (V WMH ), and we establish the I O -V WMH relationship. Our method showed accurate validations in volumetric and spatial agreements of automatically segmented WMHs compared with manually segmented WMHs for 32 confirmatory images. Bland-Altman values of volumetric agreement were 0.96 ± 8.311 ml (bias and 95 % confidence interval), and the similarity index of spatial agreement was 0.762 ± 0.127 (mean ± standard deviation). Furthermore, similar validation accuracies were obtained in the images acquired from different scanners. The proposed segmentation method uses only FLAIR MRIs, has the potential to be accurate with images obtained from different scanners, and can be implemented with a fully automated procedure. In our study, validation results were obtained with FLAIR MRIs from only two scanner types. The design of the method may allow its use in large multicenter studies with correct efficiency. (orig.)

  2. Application of variable threshold intensity to segmentation for white matter hyperintensities in fluid attenuated inversion recovery magnetic resonance images

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Byung Il; Han, Ji Won; Oh, San Yeo Wool; Kim, Tae Hui [Seoul National University Bundang Hospital, Department of Neuropsychiatry, Seongnam, Gyeonggi-do (Korea, Republic of); Lee, Jung Jae; Lee, Eun Young [Kyungbook National University Chilgok Hospital, Department of Psychiatry, Buk-gu, Daegu (Korea, Republic of); MacFall, James R. [Duke University Medical Center, Neuropsychiatric Imaging Research Laboratory, Durham, NC (United States); Duke University Medical Center, Department of Radiology, Durham, NC (United States); Payne, Martha E. [Duke University Medical Center, Neuropsychiatric Imaging Research Laboratory, Durham, NC (United States); Duke University Medical Center, Department of Psychiatry and Behavioral Sciences, Durham, NC (United States); Kim, Jae Hyoung [Seoul National University Bundang Hospital, Department of Radiology, Seongnam, Gyeonggi-do (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Kim, Ki Woong [Seoul National University Bundang Hospital, Department of Neuropsychiatry, Seongnam, Gyeonggi-do (Korea, Republic of); Seoul National University College of Medicine, Department of Psychiatry, Jongno-gu, Seoul (Korea, Republic of); Seoul National University College of Natural Sciences, Department of Brain and Cognitive Science, Gwanak-gu, Seoul (Korea, Republic of)

    2014-04-15

    White matter hyperintensities (WMHs) are regions of abnormally high intensity on T2-weighted or fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI). Accurate and reproducible automatic segmentation of WMHs is important since WMHs are often seen in the elderly and are associated with various geriatric and psychiatric disorders. We developed a fully automated monospectral segmentation method for WMHs using FLAIR MRIs. Through this method, we introduce an optimal threshold intensity (I{sub O}) for segmenting WMHs, which varies with WMHs volume (V{sub WMH}), and we establish the I{sub O} -V{sub WMH} relationship. Our method showed accurate validations in volumetric and spatial agreements of automatically segmented WMHs compared with manually segmented WMHs for 32 confirmatory images. Bland-Altman values of volumetric agreement were 0.96 ± 8.311 ml (bias and 95 % confidence interval), and the similarity index of spatial agreement was 0.762 ± 0.127 (mean ± standard deviation). Furthermore, similar validation accuracies were obtained in the images acquired from different scanners. The proposed segmentation method uses only FLAIR MRIs, has the potential to be accurate with images obtained from different scanners, and can be implemented with a fully automated procedure. In our study, validation results were obtained with FLAIR MRIs from only two scanner types. The design of the method may allow its use in large multicenter studies with correct efficiency. (orig.)

  3. 7T MRI in focal epilepsy with unrevealing conventional field strength imaging.

    Science.gov (United States)

    De Ciantis, Alessio; Barba, Carmen; Tassi, Laura; Cosottini, Mirco; Tosetti, Michela; Costagli, Mauro; Bramerio, Manuela; Bartolini, Emanuele; Biagi, Laura; Cossu, Massimo; Pelliccia, Veronica; Symms, Mark R; Guerrini, Renzo

    2016-03-01

    To assess the diagnostic yield of 7T magnetic resonance imaging (MRI) in detecting and characterizing structural lesions in patients with intractable focal epilepsy and unrevealing conventional (1.5 or 3T) MRI. We conducted an observational clinical imaging study on 21 patients (17 adults and 4 children) with intractable focal epilepsy, exhibiting clinical and electroencephalographic features consistent with a single seizure-onset zone (SOZ) and unrevealing conventional MRI. Patients were enrolled at two tertiary epilepsy surgery centers and imaged at 7T, including whole brain (three-dimensional [3D] T1 -weighted [T1W] fast-spoiled gradient echo (FSPGR), 3D susceptibility-weighted angiography [SWAN], 3D fluid-attenuated inversion recovery [FLAIR]) and targeted imaging (2D T2*-weighted dual-echo gradient-recalled echo [GRE] and 2D gray-white matter tissue border enhancement [TBE] fast spin echo inversion recovery [FSE-IR]). MRI studies at 1.5 or 3T deemed unrevealing at the referral center were reviewed by three experts in epilepsy imaging. Reviewers were provided information regarding the suspected localization of the SOZ. The same team subsequently reviewed 7T images. Agreement in imaging interpretation was reached through consensus-based discussions based on visual identification of structural abnormalities and their likely correlation with clinical and electrographic data. 7T MRI revealed structural lesions in 6 (29%) of 21 patients. The diagnostic gain in detection was obtained using GRE and FLAIR images. Four of the six patients with abnormal 7T underwent epilepsy surgery. Histopathology revealed focal cortical dysplasia (FCD) in all. In the remaining 15 patients (71%), 7T MRI remained unrevealing; 4 of the patients underwent epilepsy surgery and histopathologic evaluation revealed gliosis. 7T MRI improves detection of epileptogenic FCD that is not visible at conventional field strengths. A dedicated protocol including whole brain FLAIR and GRE images at 7T

  4. MR colonography with fecal tagging: comparison between 2D turbo FLASH and 3D FLASH sequences

    International Nuclear Information System (INIS)

    Papanikolaou, Nickolas; Grammatikakis, John; Maris, Thomas; Prassopoulos, Panos; Gourtsoyiannis, Nicholas; Lauenstein, Thomas

    2003-01-01

    The objective of this study was to compare inversion recovery turbo 2D fast low-angle shot (FLASH) and 3D FLASH sequences for fecal-tagged MR colonography studies. Fifteen consecutive patients with indications for colonoscopy underwent MR colonography with fecal tagging. An inversion recovery turbo-FLASH sequence was applied and compared in terms of artifacts presence, efficiency for masking residual stool, and colonic wall conspicuity with a fat-saturated 3D FLASH sequence. Both sequences were acquired following administration of paramagnetic contrast agent. Contrast-to-noise ratio and relative contrast between colonic wall and lumen were calculated and compared for both sequences. Turbo 2D FLASH provided fewer artifacts, higher efficiency for masking the residual stool, and colonic wall conspicuity equivalent to 3D FLASH. An inversion time of 10 ms provided homogeneously low signal intensity of the colonic lumen. Contrast to noise between colonic wall and lumen was significantly higher in the 3D FLASH images, whereas differences in relative contrast were not statistically significant. An optimized inversion-recovery 2D turbo-FLASH sequence provides better fecal tagging results and should be added to the 3D FLASH sequence when designing dark-lumen MR colonography examination protocols. (orig.)

  5. Unsupervised Pathological Area Extraction Using 3D T2 and FLAIR MR Images

    Czech Academy of Sciences Publication Activity Database

    Dvořák, P.; Bartušek, Karel; Smékal, Z.

    2014-01-01

    Roč. 14, č. 6 (2014), s. 357-364 ISSN 1335-8871 R&D Projects: GA ČR GAP102/12/1104 Institutional support: RVO:68081731 Keywords : brain tumor * brain tumor segmentation * extraction * magnetic resonance * MRI * athology * egmentation, symmetry analysis Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 0.989, year: 2014

  6. New multispectral MRI data fusion technique for white matter lesion segmentation: method and comparison with thresholding in FLAIR images

    International Nuclear Information System (INIS)

    Del C Valdes Hernandez, Maria; Ferguson, Karen J.; Chappell, Francesca M.; Wardlaw, Joanna M.

    2010-01-01

    Brain tissue segmentation by conventional threshold-based techniques may have limited accuracy and repeatability in older subjects. We present a new multispectral magnetic resonance (MR) image analysis approach for segmenting normal and abnormal brain tissue, including white matter lesions (WMLs). We modulated two 1.5T MR sequences in the red/green colour space and calculated the tissue volumes using minimum variance quantisation. We tested it on 14 subjects, mean age 73.3 ± 10 years, representing the full range of WMLs and atrophy. We compared the results of WML segmentation with those using FLAIR-derived thresholds, examined the effect of sampling location, WML amount and field inhomogeneities, and tested observer reliability and accuracy. FLAIR-derived thresholds were significantly affected by the location used to derive the threshold (P = 0.0004) and by WML volume (P = 0.0003), and had higher intra-rater variability than the multispectral technique (mean difference ± SD: 759 ± 733 versus 69 ± 326 voxels respectively). The multispectral technique misclassified 16 times fewer WMLs. Initial testing suggests that the multispectral technique is highly reproducible and accurate with the potential to be applied to routinely collected clinical MRI data. (orig.)

  7. Late gadolinium enhancement cardiac imaging on a 3T scanner with parallel RF transmission technique: prospective comparison of 3D-PSIR and 3D-IR

    International Nuclear Information System (INIS)

    Schultz, Anthony; Caspar, Thibault; Schaeffer, Mickael; Labani, Aissam; Jeung, Mi-Young; El Ghannudi, Soraya; Roy, Catherine; Ohana, Mickael

    2016-01-01

    To qualitatively and quantitatively compare different late gadolinium enhancement (LGE) sequences acquired at 3T with a parallel RF transmission technique. One hundred and sixty participants prospectively enrolled underwent a 3T cardiac MRI with 3 different LGE sequences: 3D Phase-Sensitive Inversion-Recovery (3D-PSIR) acquired 5 minutes after injection, 3D Inversion-Recovery (3D-IR) at 9 minutes and 3D-PSIR at 13 minutes. All LGE-positive patients were qualitatively evaluated both independently and blindly by two radiologists using a 4-level scale, and quantitatively assessed with measurement of contrast-to-noise ratio and LGE maximal surface. Statistical analyses were calculated under a Bayesian paradigm using MCMC methods. Fifty patients (70 % men, 56yo ± 19) exhibited LGE (62 % were post-ischemic, 30 % related to cardiomyopathy and 8 % post-myocarditis). Early and late 3D-PSIR were superior to 3D-IR sequences (global quality, estimated coefficient IR > early-PSIR: -2.37 CI = [-3.46; -1.38], prob(coef > 0) = 0 % and late-PSIR > IR: 3.12 CI = [0.62; 4.41], prob(coef > 0) = 100 %), LGE surface estimated coefficient IR > early-PSIR: -0.09 CI = [-1.11; -0.74], prob(coef > 0) = 0 % and late-PSIR > IR: 0.96 CI = [0.77; 1.15], prob(coef > 0) = 100 %. Probabilities for late PSIR being superior to early PSIR concerning global quality and CNR were over 90 %, regardless of the aetiological subgroup. In 3T cardiac MRI acquired with parallel RF transmission technique, 3D-PSIR is qualitatively and quantitatively superior to 3D-IR. (orig.)

  8. Degenerative disc disease of the lumbar spine: a prospective comparison of fast T1-weighted fluid-attenuated inversion recovery and T1-weighted turbo spin echo MR imaging

    International Nuclear Information System (INIS)

    Erdem, L. Oktay; Erdem, C. Zuhal; Acikgoz, Bektas; Gundogdu, Sadi

    2005-01-01

    Objective: To compare fast T1-weighted fluid-attenuated inversion recovery (FLAIR) and T1-weighted turbo spin-echo (TSE) imaging of the degenerative disc disease of the lumbar spine. Materials and methods: Thirty-five consecutive patients (19 females, 16 males; mean age 41 years, range 31-67 years) with suspected degenerative disc disease of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted TSE and fast T1-weighted FLAIR sequences. Two radiologists compared these sequences both qualitatively and quantitatively. Results: On qualitative evaluation, CSF nulling, contrast at the disc-CSF interface, the disc-spinal cord (cauda equina) interface, and the spinal cord (cauda equina)-CSF interface of fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.001). On quantitative evaluation of the first 15 patients, signal-to-noise ratios of cerebrospinal fluid of fast T1-weighted FLAIR imaging were significantly lower than those for T1-weighted TSE images (P < 0.05). Contrast-to-noise ratios of spinal cord/CSF and normal bone marrow/disc for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.05). Conclusion: Results in our study have shown that fast T1-weighted FLAIR imaging may be a valuable imaging modality in the armamentarium of lumbar spinal T1-weighted MR imaging, because the former technique has definite superior advantages such as CSF nulling, conspicuousness of the normal anatomic structures and changes in the lumbar spinal discogenic disease and image contrast and also almost equally acquisition times

  9. Degenerative disc disease of the lumbar spine: a prospective comparison of fast T1-weighted fluid-attenuated inversion recovery and T1-weighted turbo spin echo MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, L. Oktay [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey)]. E-mail: sunarerdem@yahoo.com; Erdem, C. Zuhal [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey); Acikgoz, Bektas [Department of Neurosurgery, Zonguldak Karaelmas University, School of Medicine, Zonguldak (Turkey); Gundogdu, Sadi [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey)

    2005-08-01

    Objective: To compare fast T1-weighted fluid-attenuated inversion recovery (FLAIR) and T1-weighted turbo spin-echo (TSE) imaging of the degenerative disc disease of the lumbar spine. Materials and methods: Thirty-five consecutive patients (19 females, 16 males; mean age 41 years, range 31-67 years) with suspected degenerative disc disease of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted TSE and fast T1-weighted FLAIR sequences. Two radiologists compared these sequences both qualitatively and quantitatively. Results: On qualitative evaluation, CSF nulling, contrast at the disc-CSF interface, the disc-spinal cord (cauda equina) interface, and the spinal cord (cauda equina)-CSF interface of fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.001). On quantitative evaluation of the first 15 patients, signal-to-noise ratios of cerebrospinal fluid of fast T1-weighted FLAIR imaging were significantly lower than those for T1-weighted TSE images (P < 0.05). Contrast-to-noise ratios of spinal cord/CSF and normal bone marrow/disc for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.05). Conclusion: Results in our study have shown that fast T1-weighted FLAIR imaging may be a valuable imaging modality in the armamentarium of lumbar spinal T1-weighted MR imaging, because the former technique has definite superior advantages such as CSF nulling, conspicuousness of the normal anatomic structures and changes in the lumbar spinal discogenic disease and image contrast and also almost equally acquisition times.

  10. Bilateral mesial temporal sclerosis: MRI with high-resolution fast spin-echo and fluid-attenuated inversion-recovery sequences

    Energy Technology Data Exchange (ETDEWEB)

    Oppenheim, C.; Dormont, D.; Lehericy, S.; Marsault, C. [Dept. of Neuroradiology, Groupe Hospitalier Pite-Salpetriere, Paris (France); Hasboun, D. [Dept. of Neuroradiology, Groupe Hospitalier Pite-Salpetriere, Paris (France)]|[Dept. of Neurology, Paris VI Univ. (France); Bazin, B.; Samson, S.; Baulac, M. [Dept. of Neurology, Paris VI Univ. (France)

    1999-07-01

    We report a retrospective analysis of MRI in 206 patients with intractable seizures and describe the findings in bilateral mesial temporal sclerosis (MTS) on fast spin-echo (FSE) and fast fluid-attenuated inversion-recovery (fFLAIR) sequences. Criteria for MTS were atrophy, signal change and loss of the digitations of the head of the hippocampus. In patients with bilateral MRI signs of MTS, correlation with clinical electro, volumetric MRI data and neuropsychological tests, when available, was performed. Bilateral MTS was observed in seven patients. Bilateral loss of the digitations and signal change of fFLAIR was seen in all seven. In three, bilateral atrophy was obvious. In two patients, mild bilateral atrophy was observed and in two others, the hippocampi were: asymmetrical, with obvious atrophy on only one side. Volumetric data confirmed bilateral symmetrical atrophy in five patients, and volumes were at the lowest of the normal range in other two. The EEG showed temporal abnormalities in all patients, unilateral in five and bilateral in two. All patients had memory impairment and neuropsychological data confirmed visual and verbal memory deficits; two patients failed the Wada test on both sides. High-resolution T2-weighted FSE and fFLAIR sequences allow diagnosis of bilateral MTS, which has important therapeutic and prognostic implications. (orig.)

  11. Bilateral mesial temporal sclerosis: MRI with high-resolution fast spin-echo and fluid-attenuated inversion-recovery sequences

    International Nuclear Information System (INIS)

    Oppenheim, C.; Dormont, D.; Lehericy, S.; Marsault, C.; Hasboun, D.; Bazin, B.; Samson, S.; Baulac, M.

    1999-01-01

    We report a retrospective analysis of MRI in 206 patients with intractable seizures and describe the findings in bilateral mesial temporal sclerosis (MTS) on fast spin-echo (FSE) and fast fluid-attenuated inversion-recovery (fFLAIR) sequences. Criteria for MTS were atrophy, signal change and loss of the digitations of the head of the hippocampus. In patients with bilateral MRI signs of MTS, correlation with clinical electro, volumetric MRI data and neuropsychological tests, when available, was performed. Bilateral MTS was observed in seven patients. Bilateral loss of the digitations and signal change of fFLAIR was seen in all seven. In three, bilateral atrophy was obvious. In two patients, mild bilateral atrophy was observed and in two others, the hippocampi were: asymmetrical, with obvious atrophy on only one side. Volumetric data confirmed bilateral symmetrical atrophy in five patients, and volumes were at the lowest of the normal range in other two. The EEG showed temporal abnormalities in all patients, unilateral in five and bilateral in two. All patients had memory impairment and neuropsychological data confirmed visual and verbal memory deficits; two patients failed the Wada test on both sides. High-resolution T2-weighted FSE and fFLAIR sequences allow diagnosis of bilateral MTS, which has important therapeutic and prognostic implications. (orig.)

  12. A semi-automated measuring system of brain diffusion and perfusion magnetic resonance imaging abnormalities in patients with multiple sclerosis based on the integration of coregistration and tissue segmentation procedures

    International Nuclear Information System (INIS)

    Revenaz, Alfredo; Ruggeri, Massimiliano; Laganà, Marcella; Bergsland, Niels; Groppo, Elisabetta; Rovaris, Marco; Fainardi, Enrico

    2016-01-01

    Diffusion-weighted imaging (DWI) and perfusion-weighted imaging (PWI) abnormalities in patients with multiple sclerosis (MS) are currently measured by a complex combination of separate procedures. Therefore, the purpose of this study was to provide a reliable method for reducing analysis complexity and obtaining reproducible results. We implemented a semi-automated measuring system in which different well-known software components for magnetic resonance imaging (MRI) analysis are integrated to obtain reliable measurements of DWI and PWI disturbances in MS. We generated the Diffusion/Perfusion Project (DPP) Suite, in which a series of external software programs are managed and harmonically and hierarchically incorporated by in-house developed Matlab software to perform the following processes: 1) image pre-processing, including imaging data anonymization and conversion from DICOM to Nifti format; 2) co-registration of 2D and 3D non-enhanced and Gd-enhanced T1-weighted images in fluid-attenuated inversion recovery (FLAIR) space; 3) lesion segmentation and classification, in which FLAIR lesions are at first segmented and then categorized according to their presumed evolution; 4) co-registration of segmented FLAIR lesion in T1 space to obtain the FLAIR lesion mask in the T1 space; 5) normal appearing tissue segmentation, in which T1 lesion mask is used to segment basal ganglia/thalami, normal appearing grey matter (NAGM) and normal appearing white matter (NAWM); 6) DWI and PWI map generation; 7) co-registration of basal ganglia/thalami, NAGM, NAWM, DWI and PWI maps in previously segmented FLAIR space; 8) data analysis. All these steps are automatic, except for lesion segmentation and classification. We developed a promising method to limit misclassifications and user errors, providing clinical researchers with a practical and reproducible tool to measure DWI and PWI changes in MS

  13. Effect of 24,25-dihydroxyvitamin D3 on 1,25-dihydroxyvitamin D3 [1,25-(OH)2D3] metabolism in vitamin D-deficient rats infused with 1,25-(OH)2D3

    International Nuclear Information System (INIS)

    Yamato, H.; Matsumoto, T.; Fukumoto, S.; Ikeda, K.; Ishizuka, S.; Ogata, E.

    1989-01-01

    Previous studies revealed that administration of 24,25-dihydroxyvitamin D3 [24,25-(OH)2D3] to calcium (Ca)-deficient rats causes a dose-dependent reduction in markedly elevated serum 1,25-(OH)2D3 level. Although the results suggested that the metabolism of 1,25-(OH)2D3 was accelerated by 24,25-(OH)2D3, those experiments could not define whether the enhanced metabolism of 1,25-(OH)2D3 played a role in the reduction in the serum 1,25-(OH)2D3 level. In the present study, in order to address this issue more specifically, serum 1,25-(OH)2D3 was maintained solely by exogenous administration through miniosmotic pumps of 1,25-(OH)2D3 into vitamin D-deficient rats. Thus, by measuring the serum 1,25-(OH)2D3 concentration, the effect of 24,25-(OH)2D3 on the MCR of 1,25-(OH)2D3 could be examined. Administration of 24,25-(OH)2D3 caused a dose-dependent enhancement in the MCR of 1,25-(OH)2D3, and 1 microgram/100 g rat.day 24,25-(OH)2D3, which elevated serum 24,25-(OH)2D3 to 8.6 +/- 1.3 ng/ml, significantly increased MCR and suppressed serum levels of 1,25-(OH)2D3. The effect of 24,25-(OH)2D3 on 1,25-(OH)2D3 metabolism developed with a rapid time course, and the recovery of iv injected [1 beta-3H]1,25-(OH)2D3 in blood was significantly reduced within 1 h. In addition, there was an increase in radioactivity in the water-soluble fraction of serum as well as in urine, suggesting that 1,25-(OH)2D3 is rapidly degraded to a water-soluble metabolite(s). Furthermore, the reduction in serum 1,25-(OH)2D3 was associated with a reduction in both serum and urinary Ca levels. Because the conversion of [3H]24,25-(OH)2D3 to [3H]1,24,25-(OH)2D3 or other metabolites was minimal in these rats, 24,25-(OH)2D3 appears to act without being converted into other metabolites. These results demonstrate that 24,25-(OH)2D3 rapidly stimulates the metabolism of 1,25-(OH)2D3 and reduces its serum level

  14. Stereoscopic 3D display with dynamic optical correction for recovering from asthenopia

    Science.gov (United States)

    Shibata, Takashi; Kawai, Takashi; Otsuki, Masaki; Miyake, Nobuyuki; Yoshihara, Yoshihiro; Iwasaki, Tsuneto

    2005-03-01

    The purpose of this study was to consider a practical application of a newly developed stereoscopic 3-D display that solves the problem of discrepancy between accommodation and convergence. The display uses dynamic optical correction to reduce the discrepancy, and can present images as if they are actually remote objects. The authors thought the display may assist in recovery from asthenopia, which is often caused when the eyes focus on a nearby object for a long time, such as in VDT (Visual Display Terminal) work. In general, recovery from asthenopia, and especially accommodative asthenopia, is achieved by focusing on distant objects. In order to verify this hypothesis, the authors performed visual acuity tests using Landolt rings before and after presenting stereoscopic 3-D images, and evaluated the degree of recovery from asthenopia. The experiment led to three main conclusions: (1) Visual acuity rose after viewing stereoscopic 3-D images on the developed display. (2) Recovery from asthenopia was particularly effective for the dominant eye in comparison with the other eye. (3) Interviews with the subjects indicated that the Landolt rings were particularly clear after viewing the stereoscopic 3-D images.

  15. Reduced CBF recovery detected by longitudinal 3D-SSP SPECT analyses predicts outcome of postoperative patients after subarachnoid haemorrhage.

    Science.gov (United States)

    Mutoh, Tatsushi; Totsune, Tomoko; Takenaka, Shunsuke; Tatewaki, Yasuko; Nakagawa, Manabu; Suarez, Jose I; Taki, Yasuyuki; Ishikawa, Tatsuya

    2018-02-01

    The aim of this study was to evaluate the impact of cerebral blood flow (CBF) recovery obtained from brain single-photon emission computed tomography (SPECT) images on postoperative outcome after aneurysmal subarachnoid haemorrhage (SAH). Twenty-nine patients who had undergone surgical clipping for ruptured anterior communicating artery aneurysms were analyzed prospectively. Routine measurements of CBF were performed using technetium-99 m hexamethyl propyleneamine oxine SPECT on days 4 and 14 after SAH. Regional voxel data analyzed by three dimensional stereotactic surface projection (3D-SSP) were compared between patients and age-matched normal database (NDB). In 3D-SSP analysis of all patients, cortical hypoperfusion around the surgical site in bilateral frontal lobes was evident on day 4 (P SSP SPECT image analyses can be a potential predictor of poor prognosis in postoperative patients after SAH. © 2017 John Wiley & Sons Australia, Ltd.

  16. Fluid-Attenuated Inversion Recovery Hypointensity of the Pulvinar Nucleus of Patients with Alzheimer Disease: Its Possible Association with Iron Accumulation as Evidenced by the T2 Map

    International Nuclear Information System (INIS)

    Moon, Won Jin; Roh, Hong Gee; Choi, Jin Woo; Kim, Hee Jin; Han, Seol Heui

    2012-01-01

    We hypothesized that prominent pulvinar hypointensity in brain MRI represents the disease process due to iron accumulation in Alzheimer disease (AD). We aimed to determine whether or not the pulvinar signal intensity (SI) on the fluid-attenuated inversion recovery (FLAIR) sequences at 3.0T MRI differs between AD patients and normal subjects, and also whether the pulvinar SI is correlated with the T2 map, an imaging marker for tissue iron, and a cognitive scale. Twenty one consecutive patients with AD and 21 age-matched control subjects were prospectively included in this study. The pulvinar SI was assessed on the FLAIR image. We measured the relative SI ratio of the pulvinar to the corpus callosum. The T2 values were calculated from the T2 relaxometry map. The differences between the two groups were analyzed, by using a Student t test. The correlation between the measurements was assessed by the Pearson's correlation test. As compared to the normal white matter, the FLAIR signal intensity of the pulvinar nucleus was significantly more hypointense in the AD patients than in the control subjects (p < 0.01). The pulvinar T2 was shorter in the AD patients than in the control subjects (51.5 ± 4.95 ms vs. 56.5 ± 5.49 ms, respectively, p = 0.003). The pulvinar SI ratio was strongly correlated with the pulvinar T2 (r = 0.745, p < 0.001). When controlling for age, only the pulvinar-to-CC SI ratio was positively correlated with that of the Mini-Mental State Examination (MMSE) score (r = 0.303, p < 0.050). Conversely, the pulvinar T2 was not correlated with the MMSE score (r = 0.277, p = 0.080). The FLAIR hypointensity of the pulvinar nucleus represents an abnormal iron accumulation in AD and may be used as an adjunctive finding for evaluating AD.

  17. Cerebrospinal Fluid Enhancement on Fluid Attenuated Inversion Recovery Images After Carotid Artery Stenting with Neuroprotective Balloon Occlusions: Hemodynamic Instability and Blood–Brain Barrier Disruption

    International Nuclear Information System (INIS)

    Ogami, Ryo; Nakahara, Toshinori; Hamasaki, Osamu; Araki, Hayato; Kurisu, Kaoru

    2011-01-01

    Purpose: A rare complication of carotid artery stenting (CAS), prolonged reversible neurological symptoms with delayed cerebrospinal fluid (CSF) space enhancement on fluid attenuated inversion recovery (FLAIR) images, is associated with blood–brain barrier (BBB) disruption. We prospectively identified patients who showed CSF space enhancement on FLAIR images. Methods: Nineteen patients—5 acute-phase and 14 scheduled—underwent 21 CAS procedures. Balloon catheters were navigated across stenoses, angioplasty was performed using a neuroprotective balloon, and stents were placed with after dilation under distal balloon protection. CSF space hyperintensity or obscuration on FLAIR after versus before CAS indicated CSF space enhancement. Correlations with clinical factors were examined. Results: CSF space was enhanced on FLAIR in 12 (57.1%) cases. Postprocedural CSF space enhancement was significantly related to age, stenosis rate, acute-stage procedure, and total occlusion time. All acute-stage CAS patients showed delayed enhancement. Only age was associated with delayed CSF space enhancement in scheduled CAS patients. Conclusions: Ischemic intolerance for severe carotid artery stenosis and temporary neuroprotective balloon occlusion, causing reperfusion injury, seem to be the main factors that underlie BBB disruption with delayed CSF space enhancement shortly after CAS, rather than sudden poststenting hemodynamic change. Our results suggest that factors related to hemodynamic instability or ischemic intolerance seem to be associated with post-CAS BBB vulnerability. Patients at risk for hemodynamic instability or with ischemic intolerance, which decrease BBB integrity, require careful management to prevent intracranial hemorrhagic and other post-CAS complications.

  18. All that glitters is not gold: Increased Signal in the Subarachnoid Space on Fluid-Attenuated Inversion Recovery Imaging after gadolinium injection

    Directory of Open Access Journals (Sweden)

    Juliana Avila Duarte

    2016-08-01

    Full Text Available A 61-year-old woman arrived at the emergency department of the Hospital Nossa Senhora das Graças, Canoas, southern Brazil, with suspected ischemic stroke. After clinical and laboratory examination, the clinical diagnosis of ischemic stroke was made, without fulfilling criteria for thrombolysis. The patient had no history of renal failure. Three days later, she performed a magnetic resonance imaging (MRI examination that confirmed the suspected diagnosis. This examination was performed without sedation or supplemental oxygen. Brain MRI was performed after gadolinium injection, using fluid-attenuated inversion recovery (FLAIR imaging, T1-weighted image, diffusion-weighted imaging, and T2-weighted image sequences that revealed signs of subacute watershed stroke in the left cerebral hemisphere (Figures 1, 2 and 3. There was a hyperintense cerebrospinal fluid (CSF in the subarachnoid space (SAS on FLAIR imaging, a finding that has been reported in many  pathologic conditions1 such as superior sagittal thrombosis, subarachnoid hemorrhage², meningitis,  meningeal carcinomatosis,  next to tumors, status epilepticus and stroke.3-7 It has also been reported in otherwise healthy patients undergoing anesthesia with supplemental oxygen.8 The exact mechanism by which CSF diffuses into the SAS in patients with or without renal insufficiency is not completely explained. Some authores have suggested that in patients with renal failure, the gadolinium may shift across an osmotic gradient at the circumventricular organs in the setting of proctracted elevation of plasma concentrations.9 We believe that the cause of this imaging phenomenon of hyperintense signal of the CSF in the SAS which has already been noted in patients with compromised cerebral perfusion, including cases of acute ischemic stroke, was due to the recent stroke.10-11 Keywords: Flair hyperintensity, MRI, stroke, Gadolinium

  19. Multi-view 3D Human Pose Estimation in Complex Environment

    NARCIS (Netherlands)

    Hofmann, K.M.; Gavrila, D.M.

    2012-01-01

    We introduce a framework for unconstrained 3D human upper body pose estimation from multiple camera views in complex environment. Its main novelty lies in the integration of three components: single-frame pose recovery, temporal integration and model texture adaptation. Single-frame pose recovery

  20. Improving automated multiple sclerosis lesion segmentation with a cascaded 3D convolutional neural network approach.

    Science.gov (United States)

    Valverde, Sergi; Cabezas, Mariano; Roura, Eloy; González-Villà, Sandra; Pareto, Deborah; Vilanova, Joan C; Ramió-Torrentà, Lluís; Rovira, Àlex; Oliver, Arnau; Lladó, Xavier

    2017-07-15

    In this paper, we present a novel automated method for White Matter (WM) lesion segmentation of Multiple Sclerosis (MS) patient images. Our approach is based on a cascade of two 3D patch-wise convolutional neural networks (CNN). The first network is trained to be more sensitive revealing possible candidate lesion voxels while the second network is trained to reduce the number of misclassified voxels coming from the first network. This cascaded CNN architecture tends to learn well from a small (n≤35) set of labeled data of the same MRI contrast, which can be very interesting in practice, given the difficulty to obtain manual label annotations and the large amount of available unlabeled Magnetic Resonance Imaging (MRI) data. We evaluate the accuracy of the proposed method on the public MS lesion segmentation challenge MICCAI2008 dataset, comparing it with respect to other state-of-the-art MS lesion segmentation tools. Furthermore, the proposed method is also evaluated on two private MS clinical datasets, where the performance of our method is also compared with different recent public available state-of-the-art MS lesion segmentation methods. At the time of writing this paper, our method is the best ranked approach on the MICCAI2008 challenge, outperforming the rest of 60 participant methods when using all the available input modalities (T1-w, T2-w and FLAIR), while still in the top-rank (3rd position) when using only T1-w and FLAIR modalities. On clinical MS data, our approach exhibits a significant increase in the accuracy segmenting of WM lesions when compared with the rest of evaluated methods, highly correlating (r≥0.97) also with the expected lesion volume. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Rapid T1 quantification based on 3D phase sensitive inversion recovery

    Directory of Open Access Journals (Sweden)

    Warntjes Marcel JB

    2010-08-01

    Full Text Available Abstract Background In Contrast Enhanced Magnetic Resonance Imaging fibrotic myocardium can be distinguished from healthy tissue using the difference in the longitudinal T1 relaxation after administration of Gadolinium, the so-called Late Gd Enhancement. The purpose of this work was to measure the myocardial absolute T1 post-Gd from a single breath-hold 3D Phase Sensitivity Inversion Recovery sequence (PSIR. Equations were derived to take the acquisition and saturation effects on the magnetization into account. Methods The accuracy of the method was investigated on phantoms and using simulations. The method was applied to a group of patients with suspected myocardial infarction where the absolute difference in relaxation of healthy and fibrotic myocardium was measured at about 15 minutes post-contrast. The evolution of the absolute R1 relaxation rate (1/T1 over time after contrast injection was followed for one patient and compared to T1 mapping using Look-Locker. Based on the T1 maps synthetic LGE images were reconstructed and compared to the conventional LGE images. Results The fitting algorithm is robust against variation in acquisition flip angle, the inversion delay time and cardiac arrhythmia. The observed relaxation rate of the myocardium is 1.2 s-1, increasing to 6 - 7 s-1 after contrast injection and decreasing to 2 - 2.5 s-1 for healthy myocardium and to 3.5 - 4 s-1 for fibrotic myocardium. Synthesized images based on the T1 maps correspond very well to actual LGE images. Conclusions The method provides a robust quantification of post-Gd T1 relaxation for a complete cardiac volume within a single breath-hold.

  2. Integrated 3D Reservoir/Fault Property Modelling Aided Well Planning and Improved Hydrocarbon Recovery in a Niger Delta Field

    International Nuclear Information System (INIS)

    Onyeagoro, U. O.; Ebong, U. E.; Nworie, E. A.

    2002-01-01

    The large and varied portfolio of assets managed by oil companies requires quick decision-making and the deployment of best in class technologies in asset management. Timely decision making and the application of the best technologies in reservoir management are however sometimes in conflict due to large time requirements of the latter.Optimizing the location of development wells is critical to account for variable fluid contact movements and pressure interference effects between wells, which can be significant because of the high permeability (Darcy range) of Niger Delta reservoirs. With relatively high drilling costs, the optimization of well locations necessitates a good realistic static and dynamic 3D reservoir description, especially in the recovery of remaining oil and oil rim type of reservoirs.A detailed 3D reservoir model with fault properties was constructed for a Niger delta producing field. This involved the integration of high quality 3D seismic, core, petrophysics, reservoir engineering, production and structural geology data to construct a realistic 3D reservoir/fault property model for the field. The key parameters considered during the construction of the internal architecture of the model were the vertical and horizontal reservoir heterogeneities-this controls the fluid flow within the reservoir. In the production realm, the fault thickness and fault permeabilities are factors that control the impedance of fluid flow across the fault-fault transmissibility. These key internal and external reservoir/structural variables were explicitly modeled in a 3D modeling software to produce different realizations and manage the uncertainties.The resulting 3D reservoir/fault property model was upscaled for simulation purpose such that grid blocks along the fault planes have realistic transmissibility multipliers of 0 to 1 attached to them. The model was also used in the well planner to optimize the positioning of a high angle deviated well that penetrated

  3. 3-D RESERVOIR AND STOCHASTIC FRACTURE NETWORK MODELING FOR ENHANCED OIL RECOVERY, CIRCLE RIDGE PHOSPHORIA/TENSLEEP RESERVOIR, WIND RIVER RESERVATION, ARAPAHO AND SHOSHONE TRIBES, WYOMING

    Energy Technology Data Exchange (ETDEWEB)

    Paul La Pointe; Jan Hermanson; Robert Parney; Thorsten Eiben; Mike Dunleavy; Ken Steele; John Whitney; Darrell Eubanks; Roger Straub

    2002-11-18

    This report describes the results made in fulfillment of contract DE-FG26-00BC15190, ''3-D Reservoir and Stochastic Fracture Network Modeling for Enhanced Oil Recovery, Circle Ridge Phosphoria/Tensleep Reservoir, Wind River Reservation, Arapaho and Shoshone Tribes, Wyoming''. The goal of this project is to improve the recovery of oil from the Tensleep and Phosphoria Formations in Circle Ridge Oilfield, located on the Wind River Reservation in Wyoming, through an innovative integration of matrix characterization, structural reconstruction, and the characterization of the fracturing in the reservoir through the use of discrete fracture network models. Fields in which natural fractures dominate reservoir permeability, such as the Circle Ridge Field, often experience sub-optimal recovery when recovery processes are designed and implemented that do not take advantage of the fracture systems. For example, a conventional waterflood in a main structural block of the Field was implemented and later suspended due to unattractive results. It is estimated that somewhere less than 20% of the OOIP in the Circle Ridge Field have been recovered after more than 50 years' production. Marathon Oil Company identified the Circle Ridge Field as an attractive candidate for several advanced IOR processes that explicitly take advantage of the natural fracture system. These processes require knowledge of the distribution of matrix porosity, permeability and oil saturations; and understanding of where fracturing is likely to be well-developed or poorly developed; how the fracturing may compartmentalize the reservoir; and how smaller, relatively untested subthrust fault blocks may be connected to the main overthrust block. For this reason, the project focused on improving knowledge of the matrix properties, the fault block architecture and to develop a model that could be used to predict fracture intensity, orientation and fluid flow/connectivity properties. Knowledge

  4. Recovery of uranium from liquors from shale attack by ion exchange; Recuperation de l'uranium des liqueurs d'attaque des schistes par echange d'ions

    Energy Technology Data Exchange (ETDEWEB)

    Parly, B; Pottier, P

    1959-04-01

    This report deals with the recovery of the uranium from a lot of shale mined at Schaentzel with an U content of 285 ppm. Recovery is realized by alkaline attack with a solution of 25 g/l Na{sub 2}CO{sub 3} at 75 C followed by absorption of the dissolved uranium by an anionic Amberlite resin, IRA 410. Final recovery is done by elution with a solution of M NaNO{sub 3}. These treatment tests determine the capacity of the resin in the case of the above solutions, verify the effects of recycling on this capacity, and finally, provide figures on the consumption of reactive and efficiency of attack and uranium recovery. (author) [French] Il s'agit de la recuperation, de l'uranium d'un lot de schiste- de Schaentzel (puits AO) dont la teneur en U est de 285 ppm. Cette recuperation consiste en une attaque alcaline par une solution de CO{sub 3}Na{sub 2} a 25 g/l et a 75 deg C. L'attaque est suivie de l'adsorption de l'uranium solubilise, sur resine anionique Amberlite IRA 410. On recupere finalement l'uranium par elution a l'aide d'une solution de NO{sub 3}Na M. Cet essai de traitement permit de determiner la capacite de la resine dans le cas de ces solutions, de verifier l'effet du recyclage sur la capacite et enfin de chiffrer la consommation en reactifs ainsi que les rendements d'attaque et de recuperation de l'uranium. (auteur)

  5. Learning Foreign Languages with ClipFlair: Using Captioning and Revoicing Activities to Increase Students' Motivation and Engagement

    Science.gov (United States)

    Baños, Rocío; Sokoli, Stavroula

    2015-01-01

    The purpose of this paper is to present the rationale and outcomes of ClipFlair, a European-funded project aimed at countering the factors that discourage Foreign Language Learning (FLL) by providing a motivating, easily accessible online platform to learn a foreign language through revoicing (e.g. dubbing) and captioning (e.g. subtitling). This…

  6. [The Role of Imaging in Central Nervous System Infections].

    Science.gov (United States)

    Yokota, Hajime; Tazoe, Jun; Yamada, Kei

    2015-07-01

    Many infections invade the central nervous system. Magnetic resonance imaging (MRI) is the main tool that is used to evaluate infectious lesions of the central nervous system. The useful sequences on MRI are dependent on the locations, such as intra-axial, extra-axial, and spinal cord. For intra-axial lesions, besides the fundamental sequences, including T1-weighted images, T2-weighted images, and fluid-attenuated inversion recovery (FLAIR) images, advanced sequences, such as diffusion-weighted imaging, diffusion tensor imaging, susceptibility-weighted imaging, and MR spectroscopy, can be applied. They are occasionally used as determinants for quick and correct diagnosis. For extra-axial lesions, understanding the differences among 2D-conventional T1-weighted images, 2D-fat-saturated T1-weighted images, 3D-Spin echo sequences, and 3D-Gradient echo sequence after the administration of gadolinium is required to avoid wrong interpretations. FLAIR plus gadolinium is a useful tool for revealing abnormal enhancement on the brain surface. For the spinal cord, the sequences are limited. Evaluating the distribution and time course of the spinal cord are essential for correct diagnoses. We summarize the role of imaging in central nervous system infections and show the pitfalls, key points, and latest information in them on clinical practices.

  7. Recovery and recrystallization of U3Si

    International Nuclear Information System (INIS)

    Caillibot, P.F.; Wyatt, B.S.

    1969-10-01

    The recovery and recrystallization temperatures of U 3 Si were determined for an alloy of uranium-3.98 wt% silicon containing 600 ppm carbon. Small specimens, deformed by compression, were isothermally and isochronally annealed at temperatures between 350 and 700 o C and their recovery and recrystallization temperatures determined using hardness, grain size and X-ray measurements. For small amounts of strain and an annealing time of 6 hours both recovery and recrystallization begin at 400-450 o C. Complete recrystallization is achieved at 650-700 o C. The effect of small changes in silicon and carbon concentration were determined by examining two further alloys containing 3.27 wt% silicon and 600 ppm carbon, and 4.02 wt% silicon and 140 ppm carbon respectively. A small change in silicon concentration does not affect recovery and recrystallization but decreasing the carbon concentration from 600 to 140 ppm decreases the recovery and recrystallization temperatures. (author)

  8. Motion-insensitive carotid intraplaque hemorrhage imaging using 3D inversion recovery preparation stack of stars (IR-prep SOS) technique.

    Science.gov (United States)

    Kim, Seong-Eun; Roberts, John A; Eisenmenger, Laura B; Aldred, Booth W; Jamil, Osama; Bolster, Bradley D; Bi, Xiaoming; Parker, Dennis L; Treiman, Gerald S; McNally, J Scott

    2017-02-01

    Carotid artery imaging is important in the clinical management of patients at risk for stroke. Carotid intraplaque hemorrhage (IPH) presents an important diagnostic challenge. 3D magnetization prepared rapid acquisition gradient echo (MPRAGE) has been shown to accurately image carotid IPH; however, this sequence can be limited due to motion- and flow-related artifact. The purpose of this work was to develop and evaluate an improved 3D carotid MPRAGE sequence for IPH detection. We hypothesized that a radial-based k-space trajectory sequence such as "Stack of Stars" (SOS) incorporated with inversion recovery preparation would offer reduced motion sensitivity and more robust flow suppression by oversampling of central k-space. A total of 31 patients with carotid disease (62 carotid arteries) were imaged at 3T magnetic resonance imaging (MRI) with 3D IR-prep Cartesian and SOS sequences. Image quality was determined between SOS and Cartesian MPRAGE in 62 carotid arteries using t-tests and multivariable linear regression. Kappa analysis was used to determine interrater reliability. In all, 25 among 62 carotid plaques had carotid IPH by consensus from the reviewers on SOS compared to 24 on Cartesian sequence. Image quality was significantly higher with SOS compared to Cartesian (mean 3.74 vs. 3.11, P SOS acquisition yielded sharper image features with less motion (19.4% vs. 45.2%, P SOS (kappa = 0.89), higher than that of Cartesian (kappa = 0.84). By minimizing flow and motion artifacts and retaining high interrater reliability, the SOS MPRAGE has important advantages over Cartesian MPRAGE in carotid IPH detection. 1 J. Magn. Reson. Imaging 2017;45:410-417. © 2016 International Society for Magnetic Resonance in Medicine.

  9. Determination of vitamin D3, vitamin D2 and their 25-hydroxy metabolites in porcine liver using high performance liquid chromatography

    International Nuclear Information System (INIS)

    Travis, B.D.; Holmes, R.P.

    1986-01-01

    A method has been developed for the determination of vitamin D 3 , vitamin D 2 and their corresponding 25-hydroxy metabolites in porcine liver. The vitamins and metabolites were estimated by extracting the non-saponifiable lipids from the saponifiable lipids from the samples. This was followed by purification and separation of the vitamin D 2 and vitamin D 3 from their 25-hydroxy metabolites using a 3 ml Bond Elut SCX column that was impregnated with silver nitrate. The two fractions were further purified on a Resolve cyanopropyl HPLC column. This column does not separate vitamin D 2 and vitamin D 3 but will separate 25-hydroxyvitamin D 2 from 25-hydroxyvitamin D 2 . Quantitation used Nova Pak C-18 and Resolve C-18 HPLC columns in series, measuring the absorbance at 254 nm. This gave baseline separation of vitamin D 2 and vitamin D 3 . Recoveries were determined by adding 3 H-vitamin D 3 and 3 H-25-hydroxyvitamin D 3 before saponification and assuming similar recoveries for the vitamin D 2 and 25-hydroxyvitamin D 2 . The method was found to be reproducible when a sample was minced and subdivided. The range of vitamin D 3 in liver was 5.2 to 14.0 ng/g. Vitamin D 2 , 25-hydroxyvitamin D 2 were not detectable. Preliminary results indicate the method may also be used with muscle, kidney and adipose, with adipose having a much higher level of vitamin D 3 than liver

  10. Ivy Sign on Fluid-Attenuated Inversion Recovery Images in Moyamoya Disease: Correlation with Clinical Severity and Old Brain Lesions.

    Science.gov (United States)

    Seo, Kwon-Duk; Suh, Sang Hyun; Kim, Yong Bae; Kim, Ji Hwa; Ahn, Sung Jun; Kim, Dong-Seok; Lee, Kyung-Yul

    2015-09-01

    Leptomeningeal collateral, in moyamoya disease (MMD), appears as an ivy sign on fluid-attenuated inversion-recovery (FLAIR) images. There has been little investigation into the relationship between presentation of ivy signs and old brain lesions. We aimed to evaluate clinical significance of ivy signs and whether they correlate with old brain lesions and the severity of clinical symptoms in patients with MMD. FLAIR images of 83 patients were reviewed. Each cerebral hemisphere was divided into 4 regions and each region was scored based on the prominence of the ivy sign. Total ivy score (TIS) was defined as the sum of the scores from the eight regions and dominant hemispheric ivy sign (DHI) was determined by comparing the ivy scores from each hemisphere. According to the degree of ischemic symptoms, patients were classified into four subgroups: 1) nonspecific symptoms without motor weakness, 2) single transient ischemic attack (TIA), 3) recurrent TIA, or 4) complete stroke. TIS was significantly different as follows: 4.86±2.55 in patients with nonspecific symptoms, 5.89±3.10 in patients with single TIA, 9.60±3.98 in patients with recurrent TIA and 8.37±3.39 in patients with complete stroke (p=0.003). TIS associated with old lesions was significantly higher than those not associated with old lesions (9.35±4.22 vs. 7.49±3.37, p=0.032). We found a significant correlation between DHI and motor symptoms (p=0.001). Because TIS has a strong tendency with severity of ischemic motor symptom and the presence of old lesions, the ivy sign may be useful in predicting severity of disease progression.

  11. Demonstration of circulating 1,24,25-trihydroxyvitamin D3 in man by radioimmunoassay

    International Nuclear Information System (INIS)

    Clemens, T.L.; Fraher, L.J.; Sandler, L.M.; O'Riordan, J.L.H.

    1982-01-01

    1,24,25-trihydroxyvitamin D 3 has been detected in human serum using a sensitive radioimmunoassay. Tritiated 1,24,25-trihydroxyvitamin D 3 was synthesized biologically and used as tracer to monitor the recovery of endogenous metabolite during isolation from serum. Circulating 1,24,25(OH) 3 D 3 in normal subjects ranged from 9.3 to 18.5 pmol/l but was not detectable ( 3 . (author)

  12. Recovery and recrystallization of U{sub 3}Si

    Energy Technology Data Exchange (ETDEWEB)

    Caillibot, P F; Wyatt, B S

    1969-10-15

    The recovery and recrystallization temperatures of U{sub 3}Si were determined for an alloy of uranium-3.98 wt% silicon containing 600 ppm carbon. Small specimens, deformed by compression, were isothermally and isochronally annealed at temperatures between 350 and 700{sup o}C and their recovery and recrystallization temperatures determined using hardness, grain size and X-ray measurements. For small amounts of strain and an annealing time of 6 hours both recovery and recrystallization begin at 400-450{sup o}C. Complete recrystallization is achieved at 650-700{sup o}C. The effect of small changes in silicon and carbon concentration were determined by examining two further alloys containing 3.27 wt% silicon and 600 ppm carbon, and 4.02 wt% silicon and 140 ppm carbon respectively. A small change in silicon concentration does not affect recovery and recrystallization but decreasing the carbon concentration from 600 to 140 ppm decreases the recovery and recrystallization temperatures. (author)

  13. Enhanced radiosensitivity in 1,25-dihydroxyvitamin D3 deficient mice

    International Nuclear Information System (INIS)

    Zhang Zengli; Ding Xiaofei; Tong Jian; Li Bingyan

    2011-01-01

    To investigate whether impaired osteogenesis resulting from vitamin D deficiency can influence hematopoiesis recovery after radiation, the 25-hydroxyvitamin D-1α-hydroxylase (1α-hydroxylase) gene knockout (KO) mice and wild type (WT) mice were subjected to different doses of gamma ray. The survival rates, peripheral blood cell counts and bone marrow cellularity were studied after irradiation (IR). The survival rates of the KO mice were significantly lower than that of WT mice after 6 or 8 Gy dose of radiation. The recovery of white blood cells in KO mice was significantly delayed compared with that in WT mice after radiation. The red blood cell number in WT mice was observed to increase more than that in KO mice at days 14 and 28 after radiation. The nadir platelet count in KO mice was nearly half of that in WT mice. Dramatically higher bone marrow cell numbers were found in WT mice compared with KO mice. Our findings demonstrate the enhanced radiosensitivity in 1,25-dihydroxyvitamin D3 (1,25-(OH) 2 D 3 ) deficient mice. (author)

  14. The usefulness of the ivy sign on fluid-attenuated intensity recovery images in improved brain hemodynamic changes after superficial temporal artery-middle cerebral artery anastomosis in adult patients with moyamoya disease.

    Science.gov (United States)

    Lee, Jung Keun; Yoon, Byul Hee; Chung, Seung Young; Park, Moon Sun; Kim, Seong Min; Lee, Do Sung

    2013-10-01

    MR perfusion and single photon emission computerized tomography (SPECT) are well known imaging studies to evaluate hemodynamic change between prior to and following superficial temporal artery (STA)-middle cerebral artery (MCA) anastomosis in moyamoya disease. But their side effects and invasiveness make discomfort to patients. We evaluated the ivy sign on MR fluid attenuated inversion recovery (FLAIR) images in adult patients with moyamoya disease and compared it with result of SPECT and MR perfusion images. We enrolled twelve patients (thirteen cases) who were diagnosed with moyamoya disease and underwent STA-MCA anastomosis at our medical institution during a period ranging from September of 2010 to December of 2012. The presence of the ivy sign on MR FLAIR images was classified as Negative (0), Minimal (1), and Positive (2). Regions were classified into four territories: the anterior cerebral artery (ACA), the anterior MCA, the posterior MCA and the posterior cerebral artery. Ivy signs on preoperative and postoperative MR FLAIR were improved (8 and 4 in the ACA regions, 13 and 4 in the anterior MCA regions and 19 and 9 in the posterior MCA regions). Like this result, the cerebrovascular reserve (CVR) on SPECT was significantly increased in the sum of CVR in same regions after STA-MCA anastomosis. After STA-MCA anastomosis, ivy signs were decreased in the cerebral hemisphere. As compared with conventional diagnostic modalities such as SPECT and MR perfusion images, the ivy sign on MR FLAIR is considered as a useful indicator in detecting brain hemodynamic changes between preoperatively and postoperatively in adult moyamoya patients.

  15. An evolution from 3D face-centered-cubic ZnSnO3 nanocubes to 2D orthorhombic ZnSnO3 nanosheets with excellent gas sensing performance

    International Nuclear Information System (INIS)

    Chen Yuejiao; Yu Ling; Li Qing; Wu Yan; Li Qiuhong; Wang Taihong

    2012-01-01

    We have successfully observed the development of three-dimensional (3D) face-centered-cubic ZnSnO 3 into two-dimensional (2D) orthorhombic ZnSnO 3 nanosheets, which is the first observation of 2D ZnSnO 3 nanostructures to date. The synthesis from 3D to 2D nanostructures is realized by the dual-hydrolysis-assisted liquid precipitation reaction and subsequent hydrothermal treatment. The time-dependent morphology indicates the transformation via a ‘dissolution–recrystallization’ mechanism, accompanied by a ‘further growth’ process. Furthermore, the 2D ZnSnO 3 nanosheets consist of smaller sized nanoflakes. This further increases the special specific surface area and facilitates their application in gas sensing. The 2D ZnSnO 3 nanosheets exhibit excellent gas sensing properties, especially through their ultra-fast response and recovery. When exposed to ethanol and acetone, the response rate is as fast as 0.26 s and 0.18 s, respectively, and the concentration limit can reach as low as 50 ppb of ethanol. All these results are much better than those reported so far. Our experimental results indicate an efficient approach to realize high-performance gas sensors. (paper)

  16. Conspicuity of diffuse axonal injury lesions on diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Kinoshita, Toshibumi; Moritani, Toshio; Hiwatashi, Akio; Wang, Henry Z.; Shrier, David A.; Numaguchi, Yuji; Westesson, Per-Lennart A.

    2005-01-01

    Objective: (1) To detect diffuse axonal injury (DAI) lesions by diffusion-weighted imaging (DWI), as compared with fluid-attenuated inversion recovery (FLAIR) imaging and (2) to evaluate hemorrhagic DAI lesions by b 0 images obtained from DWI, as compared with gradient-echo (GRE) imaging. Methods: We reviewed MR images of 36 patients with a diagnosis of DAI. MR imaging was performed 20 h to 14 days (mean, 3.7 days) after traumatic brain injury. We evaluated: (1) conspicuity of lesions on DWI and FLAIR and (2) conspicuity of hemorrhage in DAI lesions on b 0 images and GRE imaging. Results: DWI clearly depicted high-signal DAI lesions. The sensitivity of DWI to lesional conspicuity in DAI lesions was almost equal to that of FLAIR. The sensitivity of b 0 images to identification of hemorrhagic DAI lesions was inferior to that of GRE. Conclusion: DWI is as useful as FLAIR in detecting DAI lesions. GRE imaging is still the superior tool for the evaluation of hemorrhagic DAI

  17. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi

    1998-01-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T 2 -weighted (T 2 W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T 2 W imaging was performed, EPI-T 2 W imaging yielded superior results compared with SE-T 2 W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T 2 W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T 2 W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  18. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1998-06-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T{sub 2}-weighted (T{sub 2}W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T{sub 2}W imaging was performed, EPI-T{sub 2}W imaging yielded superior results compared with SE-T{sub 2}W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T{sub 2}W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T{sub 2}W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  19. Industrial Waste Heat Recovery - Potential Applications, Available Technologies and Crosscutting R&D Opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Thekdi, Arvind [E3M Inc, North Potomac, MD (United States); Nimbalkar, Sachin U. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    The purpose of this report was to explore key areas and characteristics of industrial waste heat and its generation, barriers to waste heat recovery and use, and potential research and development (R&D) opportunities. The report also provides an overview of technologies and systems currently available for waste heat recovery and discusses the issues or barriers for each. Also included is information on emerging technologies under development or at various stages of demonstrations, and R&D opportunities cross-walked by various temperature ranges, technology areas, and energy-intensive process industries.

  20. Utilizing 18F-fluoroethyltyrosine (FET) positron emission tomography (PET) to define suspected nonenhancing tumor for radiation therapy planning of glioblastoma.

    Science.gov (United States)

    Hayes, Aimee R; Jayamanne, Dasantha; Hsiao, Edward; Schembri, Geoffrey P; Bailey, Dale L; Roach, Paul J; Khasraw, Mustafa; Newey, Allison; Wheeler, Helen R; Back, Michael

    2018-01-31

    The authors sought to evaluate the impact of 18F-fluoroethyltyrosine (FET) positron emission tomography (PET) on radiation therapy planning for patients diagnosed with glioblastoma (GBM) and the presence of suspected nonenhancing tumors compared with standard magnetic resonance imaging (MRI). Patients with GBM and contrast-enhanced MRI scans showing regions suspicious of nonenhancing tumor underwent postoperative FET-PET before commencing radiation therapy. Two clinical target volumes (CTVs) were created using pre- and postoperative MRI: MRI fluid-attenuated inversion recovery (FLAIR) sequences (CTV FLAIR ) and MRI contrast sequences with an expansion on the surgical cavity (CTV Sx ). FET-PET was used to create biological tumor volumes (BTVs) by encompassing FET-avid regions, forming BTV FLAIR and BTV Sx . Volumetric analyses were conducted between CTVs and respective BTVs using Wilcoxon signed-rank tests. The volume increase with addition of FET was analyzed with respect to BTV FLAIR and BTV Sx . Presence of focal gadolinium contrast enhancement within previously nonenhancing tumor or within the FET-avid region was noted on MRI scans at 1 and 3 months after radiation therapy. Twenty-six patients were identified retrospectively from our database, of whom 24 had demonstrable FET uptake. The median CTV FLAIR , CTV Sx , BTV FLAIR , and BTV Sx were 57.1 mL (range, 1.1-217.4), 83.6 mL (range, 27.2-275.8), 62.8 mL (range, 1.1-307.3), and 94.7 mL (range, 27.2-285.5), respectively. When FET-PET was used, there was a mean increase in volume of 26.8% from CTV FLAIR to BTV FLAIR and 20.6% from CTV Sx to BTV Sx . A statistically significant difference was noted on Wilcoxon signed-rank test when assessing volumetric change between CTV FLAIR and BTV FLAIR (P Wilcoxon signed-rank tests. FET-PET may help improve delineation of GBM in cases with a suspected nonenhancing component and reduce the risk of potential geographical miss. Copyright © 2018 American Society for Radiation

  1. Glass-like recovery of antiferromagnetic spin ordering in a photo-excited manganite Pr0.7Ca0.3MnO3

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, S. Y.; Langner, M. C.; Zhu, Y.; Chuang, Y. -D.; Rini, M.; Glover, T. E.; Hertlein, M. P.; Gonzalez, A.G. Cruz; Tahir, N.; Tomioka, Y.; Tokura, Y.; Hussain, Z.; Schoenlein, R. W.

    2014-01-16

    Electronic orderings of charges, orbitals and spins are observed in many strongly correlated electron materials, and revealing their dynamics is a critical step toward understanding the underlying physics of important emergent phenomena. Here we use time-resolved resonant soft x-ray scattering spectroscopy to probe the dynamics of antiferromagnetic spin ordering in the manganite Pr0:7Ca0:3MnO3 following ultrafast photo-exitation. Our studies reveal a glass-like recovery of the spin ordering and a crossover in the dimensionality of the restoring interaction from quasi-1D at low pump fluence to 3D at high pump fluence. This behavior arises from the metastable state created by photo-excitation, a state characterized by spin disordered metallic droplets within the larger charge- and spin-ordered insulating domains. Comparison with time-resolved resistivity measurements suggests that the collapse of spin ordering is correlated with the insulator-to-metal transition, but the recovery of the insulating phase does not depend on the re-establishment of the spin ordering.

  2. Determination of vitamins D2, D3, K1 and K3 and some hydroxy metabolites of vitamin D3 in plasma using a continuous clean-up-preconcentration procedure coupled on-line with liquid chromatography-UV detection.

    Science.gov (United States)

    Ortiz Boyer, F; Fernández Romero, J M; Luque de Castro, M D; Quesada, J M

    1999-03-01

    A semi-automatic procedure for the continuous clean-up and concentration of several fat-soluble vitamins prior to their separation by HPLC and UV detection is reported. The procedure is based on the use of a minicolumn packed with aminopropylsilica as sorbent located prior to the chromatographic detection system. The overall process was developed and applied to the main liposoluble vitamins (A, D2, D3, E, K1, K3) and several hydroxy metabolites of vitamin D3 [25-(OH)-D3,24,25-(OH)2-D3 and 1,25-(OH)2-D3]. All the analytes were monitored at a compromise wavelength of 270 nm. Calibration graphs were constructed between 0.01 and 100 ng ml-1 for vitamin D2 and D3 and their hydroxy metabolites, between 0.1 and 100 ng ml-1 for vitamin A, K1 and K3 and between 1 and 100 ng ml-1 for vitamin E, with excellent regression coefficients (> or = 0.9901) in all cases. The precision was established at two concentration levels with acceptable RSDs in all instances (between 3.6 and 8.7%). The method was appropriate for the determination of vitamin D2, D3, K1 and K3 and the 24,25-dihydroxy and 25-hydroxy metabolites of vitamin D3 in human plasma. The method was applied to plasma samples spiked with the target analytes and the recoveries ranged between 78 and 109%.

  3. 3D surface reconstruction using optical flow for medical imaging

    International Nuclear Information System (INIS)

    Weng, Nan; Yang, Yee-Hong; Pierson, R.

    1996-01-01

    The recovery of a 3D model from a sequence of 2D images is very useful in medical image analysis. Image sequences obtained from the relative motion between the object and the camera or the scanner contain more 3D information than a single image. Methods to visualize the computed tomograms can be divided into two approaches: the surface rendering approach and the volume rendering approach. A new surface rendering method using optical flow is proposed. Optical flow is the apparent motion in the image plane produced by the projection of the real 3D motion onto 2D image. In this paper, the object remains stationary while the scanner undergoes translational motion. The 3D motion of an object can be recovered from the optical flow field using additional constraints. By extracting the surface information from 3D motion, it is possible to get an accurate 3D model of the object. Both synthetic and real image sequences have been used to illustrate the feasibility of the proposed method. The experimental results suggest that the proposed method is suitable for the reconstruction of 3D models from ultrasound medical images as well as other computed tomograms

  4. 3D Printed Photoresponsive Devices Based on Shape Memory Composites.

    Science.gov (United States)

    Yang, Hui; Leow, Wan Ru; Wang, Ting; Wang, Juan; Yu, Jiancan; He, Ke; Qi, Dianpeng; Wan, Changjin; Chen, Xiaodong

    2017-09-01

    Compared with traditional stimuli-responsive devices with simple planar or tubular geometries, 3D printed stimuli-responsive devices not only intimately meet the requirement of complicated shapes at macrolevel but also satisfy various conformation changes triggered by external stimuli at the microscopic scale. However, their development is limited by the lack of 3D printing functional materials. This paper demonstrates the 3D printing of photoresponsive shape memory devices through combining fused deposition modeling printing technology and photoresponsive shape memory composites based on shape memory polymers and carbon black with high photothermal conversion efficiency. External illumination triggers the shape recovery of 3D printed devices from the temporary shape to the original shape. The effect of materials thickness and light density on the shape memory behavior of 3D printed devices is quantified and calculated. Remarkably, sunlight also triggers the shape memory behavior of these 3D printed devices. This facile printing strategy would provide tremendous opportunities for the design and fabrication of biomimetic smart devices and soft robotics. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Disorder accumulation and recovery in gold-ion irradiated 3C-SiC

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Weilin; Weber, William J.; Lian, Jie; Kalkhoran, N. M.

    2009-01-12

    A single-crystal 3C-SiC film on the Si/SiO2/Si (SIMOX) substrate was irradiated in different areas at 156 K with Au2+ ions to low fluences. The disorder profiles as a function of dose on both the Si and C sublattices have been determined in situ using a combination of 0.94 MeV D+ Rutherford backscattering spectrometry and nuclear reaction analysis in channeling geometry along the <100>, <110> and <111> axes. The results indicate that for the same damage state, the level of disorder on the Si sublattice in 3C-SiC follows a decreasing order along the <111>, <100> and <110> axes, while that on the C sublattice shows comparable values. Similar levels of Si and C disorder are observed along the <111> axis over the applied dose range. However, the level of C disorder is higher than that of Si disorder along either <100> or <110>. The amount of disorder recovery during thermal annealing processes depends on the sublattice (Si or C) and crystallographic orientation. Room-temperature recovery occurs for both sublattices in 3C-SiC irradiated to a dose of 0.047 dpa or lower. Significant recovery is observed along all directions during thermal annealing at 600 K. The results will be discussed and compared to those for 6H- and 4H-SiC under similar irradiation conditions.

  6. Is 3D MPRAGE better than the combination DIR/PSIR for cortical lesion detection at 3T MRI?

    Science.gov (United States)

    Nelson, Flavia; Poonawalla, Aziz; Datta, Sushmita; Wolinsky, Jerry; Narayana, Ponnada

    2014-03-01

    Based on the application of newer magnetic resonance imaging (MRI) acquisition sequences, the detection of cortical lesions (CL) in multiple sclerosis (MS) has significantly improved. Double inversion recovery (DIR) at 3T has increased the detection sensitivity and classification specificity when combined with phase sensitive inversion recovery (PSIR). Previous findings with 3D magnetization prepared rapid acquisition with gradient echo (MPRAGE) sequences, showed improved classification specificity of purely intracortical (IC) and mixed (MX) lesions, compared to the classification based on DIR/PSIR. Direct comparison between the detection of CL by 3D MPRAGE and by DIR/PSIR at 3T has not been evaluated. Eleven subjects were imaged on a 3T magnet. DIR/PSIR and 3D MPRAGE images were reviewed independently. Each image set was reviewed twice; only lesions detected on both sessions were scored. Review time per scan was ~5min for DIR/PSIR and ~15min for 3D MPRAGE. We identified 141 CL (62 IC+79 MX) based on DIR/PSIR images vs. 93 (38 IC+55 MX) based on MPRAGE from all eleven patients. MPRAGE under-detected the number of CL in seven cases and over-detected the number of CL in three, only one case had the same number of CL on both sets of images. Combination DIR/PSIR at 3T is superior to 3D MPRAGE for detection of cortical gray matter lesions in MS. The contrast-to-noise ratio of CL appears to be inferior on the MPRAGE images relative to DIR/PSIR. © 2013 Published by Elsevier B.V.

  7. Applying 3D-printing technology in planning operations of cancer patients

    Science.gov (United States)

    Kashapov, L. N.; N, A. N. Rudyk A.; Kashapov, R. N.

    2014-12-01

    The purpose of this work was creation 3D model of the front part of the skull of the patient and evaluates the effectiveness of its use in the planning of the operation. To achieve this goal was chosen an operation to remove a tumor of the right eyelid, germinate in the zygomatic bone. 3D printing was performed at different peripheral devices using the method of layering creating physical objects by a digital 3D model as well as the recovery model of the skull with the entire right malar bone for fixation on her titanium frame to maintain the eyeball in a fixed state.

  8. Conspicuity of diffuse axonal injury lesions on diffusion-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Toshibumi [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States)]. E-mail: kino@grape.med.tottori-u.ac.jp; Moritani, Toshio [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States); Hiwatashi, Akio [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States); Wang, Henry Z. [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States); Shrier, David A. [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States); Numaguchi, Yuji [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States); Westesson, Per-Lennart A. [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States)

    2005-10-01

    Objective: (1) To detect diffuse axonal injury (DAI) lesions by diffusion-weighted imaging (DWI), as compared with fluid-attenuated inversion recovery (FLAIR) imaging and (2) to evaluate hemorrhagic DAI lesions by b{sub 0} images obtained from DWI, as compared with gradient-echo (GRE) imaging. Methods: We reviewed MR images of 36 patients with a diagnosis of DAI. MR imaging was performed 20 h to 14 days (mean, 3.7 days) after traumatic brain injury. We evaluated: (1) conspicuity of lesions on DWI and FLAIR and (2) conspicuity of hemorrhage in DAI lesions on b{sub 0} images and GRE imaging. Results: DWI clearly depicted high-signal DAI lesions. The sensitivity of DWI to lesional conspicuity in DAI lesions was almost equal to that of FLAIR. The sensitivity of b{sub 0} images to identification of hemorrhagic DAI lesions was inferior to that of GRE. Conclusion: DWI is as useful as FLAIR in detecting DAI lesions. GRE imaging is still the superior tool for the evaluation of hemorrhagic DAI.

  9. Test results of Nb3Sn ribbons for the Princeton D coil test program

    International Nuclear Information System (INIS)

    Kaugerts, J.; File, J.; Willard, J.W.

    1974-10-01

    A previously described D coil test program was modified. Details of a smaller Nb 3 Sn D coil test program are described. Cusp coil tests were made with several Nb 3 Sn composite ribbons. Measurements of both the quench and recovery currents as a function of magnetic field component perpendicular to the wide edge of the ribbon are presented. (auth)

  10. Dopamine D1 receptor activation maintains motor coordination in injured rats but does not accelerate the recovery of the motor coordination deficit.

    Science.gov (United States)

    Avila-Luna, Alberto; Gálvez-Rosas, Arturo; Alfaro-Rodríguez, Alfonso; Reyes-Legorreta, Celia; Garza-Montaño, Paloma; González-Piña, Rigoberto; Bueno-Nava, Antonio

    2018-01-15

    The sensorimotor cortex and the striatum are interconnected by the corticostriatal pathway, suggesting that cortical injury alters the striatal function that is associated with skilled movements and motor learning, which are functions that may be modulated by dopamine (DA). In this study, we explored motor coordination and balance in order to investigate whether the activation of D 1 receptors (D 1 Rs) modulates functional recovery after cortical injury. The results of the beam-walking test showed motor deficit in the injured group at 24, 48 and 96h post-injury, and the recovery time was observed at 192h after cortical injury. In the sham and injured rats, systemic administration of the D 1 R antagonist SCH-23390 (1mg/kg) alone at 24, 48, 96 and 192h significantly (Pmotor deficit, while administration of the D 1 R agonist SKF-38393 alone (2, 3 and 4mg/kg) at 24, 48, 96 and 192h post-injury did not produce a significant difference; however, the co-administration of SKF-38393 and SCH-23390 prevented the antagonist-induced increase in the motor deficit. The cortical+striatal injury showed significantly increased the motor deficit at 24, 48, 96 and 192h post-injury (Pmotor recovery, but the activation of D 1 Rs maintained motor coordination, confirming that an intact striatum may be necessary for achieving recovery. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Cognitive Function and 3-Tesla Magnetic Resonance Imaging Tractography of White Matter Hyperintensities in Elderly Persons.

    Science.gov (United States)

    Reginold, William; Luedke, Angela C; Tam, Angela; Itorralba, Justine; Fernandez-Ruiz, Juan; Reginold, Jennifer; Islam, Omar; Garcia, Angeles

    2015-01-01

    This study used 3-Tesla magnetic resonance imaging (MRI) tractography to determine if there was an association between tracts crossing white matter hyperintensities (WMH) and cognitive function in elderly persons. Brain T2-weighted fluid-attenuated inversion recovery (FLAIR) and diffusion tensor MRI scans were acquired in participants above the age of 60 years. Twenty-six persons had WMH identified on T2 FLAIR scans. They completed a battery of neuropsychological tests and were classified as normal controls (n = 15) or with Alzheimer's dementia (n = 11). Tractography was generated by the Fiber Assignment by Continuous Tracking method. All tracts that crossed WMH were segmented. The average fractional anisotropy and average mean diffusivity of these tracts were quantified. We studied the association between cognitive test scores with the average mean diffusivity and average fractional anisotropy of tracts while controlling for age, total WMH volume and diagnosis. An increased mean diffusivity of tracts crossing WMH was associated with worse performance on the Wechsler Memory Scale-III Longest Span Forward (p = 0.02). There was no association between the fractional anisotropy of tracts and performance on cognitive testing. The mean diffusivity of tracts crossing WMH measured by tractography is a novel correlate of performance on the Wechsler Memory Scale-III Longest Span Forward in elderly persons.

  12. 26 CFR 7.57(d)-1 - Election with respect to straight line recovery of intangibles.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 14 2010-04-01 2010-04-01 false Election with respect to straight line recovery... ACT OF 1976 § 7.57(d)-1 Election with respect to straight line recovery of intangibles. (a) Purpose... Tax Reform Act of 1976. Under this election taxpayers may use cost depletion to compute straight line...

  13. Predictors of short-term outcome in patients with acute middle cerebral artery occlusion: unsuitability of fluid-attenuated inversion recovery vascular hyperintensity scores

    Directory of Open Access Journals (Sweden)

    Chan-chan Li

    2018-01-01

    Full Text Available Fluid-attenuated inversion recovery (FLAIR vascular hyperintensity (FVH is used to assess leptomeningeal collateral circulation, but clinical outcomes of patients with FVH can be very different. The aim of the present study was to assess a FVH score and explore its relationship with clinical outcomes. Patients with acute ischemic stroke due to middle cerebral artery M1 occlusion underwent magnetic resonance imaging and were followed up at 10 days (National Institutes of Health Stroke Scale and 90 days (modified Rankin Scale to determine short-term clinical outcomes. Effective collateral circulation indirectly improved recovery of neurological function and short-term clinical outcome by extending the size of the pial penumbra and reducing infarct lesions. FVH score showed no correlation with 90-day functional clinical outcome and was not sufficient as an independent predictor of short-term clinical outcome.

  14. A 3D nanofibrous hydrogel and collagen sponge scaffold promotes locomotor functional recovery, spinal repair, and neuronal regeneration after complete transection of the spinal cord in adult rats

    International Nuclear Information System (INIS)

    Kaneko, Ai; Matsushita, Akira; Sankai, Yoshiyuki

    2015-01-01

    Central nervous system neurons in adult mammals display limited regeneration after injury, and functional recovery is poor following complete transection (>4 mm gap) of a rat spinal cord. A novel combination scaffold composed of 3D nanofibrous hydrogel PuraMatrix and a honeycomb collagen sponge was used to promote spinal repair and locomotor functional recovery following complete transection of the spinal cord in rats. We transplanted this scaffold into 5 mm spinal cord gaps and assessed spinal repair and functional recovery using the Basso, Beattie, and Bresnahan (BBB) locomotor scale. The BBB score of the scaffold-transplanted group was significantly higher than that of the PBS-injected control group from 24 d to 4 months after the operation (P < 0.001–0.01), reaching 6.0  ±  0.75 (mean ± SEM) in the transplant and 0.70  ±  0.46 in the control groups. Neuronal regeneration and spinal repair were examined histologically using Pan Neuronal Marker, glial fibrillary acidic protein, growth-associated protein 43, and DAPI. The scaffolds were well integrated into the spinal cords, filling the 5 mm gaps with higher numbers of regenerated and migrated neurons, astrocytes, and other cells than in the control group. Mature and immature neurons and astrocytes in the scaffolds became colocalized and aligned longitudinally over >2 mm, suggesting their differentiation, maturation, and function. The spinal cord NF200 content of the transplant group, analyzed by western blot, was more than twice that of the control group, supporting the histological results. Transplantation of this novel scaffold promoted functional recovery, spinal repair, and neuronal regeneration. (paper)

  15. Recovery of inclusions in 2D and 3D domains for Poisson’s equation

    International Nuclear Information System (INIS)

    Ito, Kazufumi; Liu, Ji-Chuan

    2013-01-01

    In this paper, we consider the recovery problem of inclusions in three-dimensional and three-dimensional domains for Poisson’s equation from noisy observation data. We propose effective reconstruction algorithms to recover hidden inclusions within a body when one can only make measurements of voltage and current on the external boundary. Our motivation is to detect the number, the location, the size and the shape of inclusions. This problem is nonlinear and severely ill posed, thus we should apply regularization techniques in our approaches in order to improve the corresponding approximation. We give several examples to show the viability of our proposed methods. (paper)

  16. Case study: Beauty and the Beast 3D: benefits of 3D viewing for 2D to 3D conversion

    Science.gov (United States)

    Handy Turner, Tara

    2010-02-01

    From the earliest stages of the Beauty and the Beast 3D conversion project, the advantages of accurate desk-side 3D viewing was evident. While designing and testing the 2D to 3D conversion process, the engineering team at Walt Disney Animation Studios proposed a 3D viewing configuration that not only allowed artists to "compose" stereoscopic 3D but also improved efficiency by allowing artists to instantly detect which image features were essential to the stereoscopic appeal of a shot and which features had minimal or even negative impact. At a time when few commercial 3D monitors were available and few software packages provided 3D desk-side output, the team designed their own prototype devices and collaborated with vendors to create a "3D composing" workstation. This paper outlines the display technologies explored, final choices made for Beauty and the Beast 3D, wish-lists for future development and a few rules of thumb for composing compelling 2D to 3D conversions.

  17. 3D splint prototype system for applications in muscular rehab by transcutaneous electrical nerve stimulation (TENS)

    Science.gov (United States)

    Saldaña-Martínez, M. I.; Guzmán-González, J. V.; Barajas-González, O. G.; Guzman-Ramos, V.; García-Garza, A. K.; González-García, R. B.; García-Ramírez, M. A.

    2017-03-01

    It is quite common that patients with ligamentous ruptures, tendonitis, tenosynovitis or sprains are foreseen the use of ad hoc splints for a swift recovery. In this paper, we propose a rehabilitation split that is focused on upper-limb injuries. By considering that upper-limb patient shows a set of different characteristics, our proposal personalizes and prints the splint custom made though a digital model that is generated by a 3D commercial scanner. To fabricate the 3D scanned model the Stereolithography material (SLA) is considered due to the properties that this material offers. In order to complement the recovery process, an electronic system is implemented within the splint design. This system generates a set of pulses for a fix period of time that focuses mainly on a certain group of muscles to allow a fast recovery process known as Transcutaneous Electrical Nerve Stimulation Principle (TENS).

  18. Morphometric changes of whole brain in patients with alcohol addiction: a voxel-based morphometry study

    International Nuclear Information System (INIS)

    Li Jinfeng; Chen Zhiye; Ma Lin

    2011-01-01

    Objective: To evaluate morphometric changes of brain in patients with alcohol addiction by voxel-based morphometry. Methods: Fifteen patients with alcohol addiction and 15 health controls were recruited and underwent fluid attenuated inversion recovery (FLAIR) and 3D fast spoiled gradient echo (FSPGR) T 1 -weighted sequences on a 3.0 T MRI system. 3D FSPGR T 1 structure images were normalized, segmented and smoothed, and then underwent voxel-based morphometry. An ANCOVA was applied with age, body mass index (BMI), and education years as covariates because of exact sex match. A statistical threshold of P 0.05). Conclusions: Regional gray and white matter atrophy can be the initial changes in patients with alcohol addiction and the frontal region is a relative specific damaged brain region. VBM has a potential value for the detection of subtle brain atrophy in patients with alcohol addiction. (authors)

  19. Refined 3d-3d correspondence

    Energy Technology Data Exchange (ETDEWEB)

    Alday, Luis F.; Genolini, Pietro Benetti; Bullimore, Mathew; Loon, Mark van [Mathematical Institute, University of Oxford, Andrew Wiles Building,Radcliffe Observatory Quarter, Woodstock Road, Oxford, OX2 6GG (United Kingdom)

    2017-04-28

    We explore aspects of the correspondence between Seifert 3-manifolds and 3d N=2 supersymmetric theories with a distinguished abelian flavour symmetry. We give a prescription for computing the squashed three-sphere partition functions of such 3d N=2 theories constructed from boundary conditions and interfaces in a 4d N=2{sup ∗} theory, mirroring the construction of Seifert manifold invariants via Dehn surgery. This is extended to include links in the Seifert manifold by the insertion of supersymmetric Wilson-’t Hooft loops in the 4d N=2{sup ∗} theory. In the presence of a mass parameter for the distinguished flavour symmetry, we recover aspects of refined Chern-Simons theory with complex gauge group, and in particular construct an analytic continuation of the S-matrix of refined Chern-Simons theory.

  20. YouDash3D: exploring stereoscopic 3D gaming for 3D movie theaters

    Science.gov (United States)

    Schild, Jonas; Seele, Sven; Masuch, Maic

    2012-03-01

    Along with the success of the digitally revived stereoscopic cinema, events beyond 3D movies become attractive for movie theater operators, i.e. interactive 3D games. In this paper, we present a case that explores possible challenges and solutions for interactive 3D games to be played by a movie theater audience. We analyze the setting and showcase current issues related to lighting and interaction. Our second focus is to provide gameplay mechanics that make special use of stereoscopy, especially depth-based game design. Based on these results, we present YouDash3D, a game prototype that explores public stereoscopic gameplay in a reduced kiosk setup. It features live 3D HD video stream of a professional stereo camera rig rendered in a real-time game scene. We use the effect to place the stereoscopic effigies of players into the digital game. The game showcases how stereoscopic vision can provide for a novel depth-based game mechanic. Projected trigger zones and distributed clusters of the audience video allow for easy adaptation to larger audiences and 3D movie theater gaming.

  1. Low Levels of the 150-kD Insulin -Like Growth Factor Binding Protein 3 Ternary complex in Patients with Anorexia nervosa

    DEFF Research Database (Denmark)

    Støving, René K; Hangaard, Jørgen; Hagen, Claus

    2003-01-01

    women with AN at the time of diagnosis and after partial weight recovery and in 6 healthy age-matched women serving as controls. RESULTS: Patients with AN had low levels of ALS and IGFBP-3 contained in the 150-kD ternary complex and in the non-150-kD fraction. Following partial weight recovery, the 150......-kD IGFBP-3 ternary complex was fully normalized, despite only partial normalization of serum GH and IGF-I levels. Patients with AN did not present with IGFBP-3 proteolysis different from controls. CONCLUSION: The present data indicate a pivotal role of the nutritional status in the regulation...

  2. Evaluation of the combined effects of target size, respiratory motion and background activity on 3D and 4D PET/CT images

    International Nuclear Information System (INIS)

    Park, Sang-June; Ionascu, Dan; Killoran, Joseph; Chin, Lee; Berbeco, Ross; Mamede, Marcelo; Gerbaudo, Victor H

    2008-01-01

    Gated (4D) PET/CT has the potential to greatly improve the accuracy of radiotherapy at treatment sites where internal organ motion is significant. However, the best methodology for applying 4D-PET/CT to target definition is not currently well established. With the goal of better understanding how to best apply 4D information to radiotherapy, initial studies were performed to investigate the effect of target size, respiratory motion and target-to-background activity concentration ratio (TBR) on 3D (ungated) and 4D PET images. Using a PET/CT scanner with 4D or gating capability, a full 3D-PET scan corrected with a 3D attenuation map from 3D-CT scan and a respiratory gated (4D) PET scan corrected with corresponding attenuation maps from 4D-CT were performed by imaging spherical targets (0.5-26.5 mL) filled with 18 F-FDG in a dynamic thorax phantom and NEMA IEC body phantom at different TBRs (infinite, 8 and 4). To simulate respiratory motion, the phantoms were driven sinusoidally in the superior-inferior direction with amplitudes of 0, 1 and 2 cm and a period of 4.5 s. Recovery coefficients were determined on PET images. In addition, gating methods using different numbers of gating bins (1-20 bins) were evaluated with image noise and temporal resolution. For evaluation, volume recovery coefficient, signal-to-noise ratio and contrast-to-noise ratio were calculated as a function of the number of gating bins. Moreover, the optimum thresholds which give accurate moving target volumes were obtained for 3D and 4D images. The partial volume effect and signal loss in the 3D-PET images due to the limited PET resolution and the respiratory motion, respectively were measured. The results show that signal loss depends on both the amplitude and pattern of respiratory motion. However, the 4D-PET successfully recovers most of the loss induced by the respiratory motion. The 5-bin gating method gives the best temporal resolution with acceptable image noise. The results based on the 4D

  3. Technology strategy for enhanced recovery; Technology Target Areas; TTA3 - enhanced recovery

    Energy Technology Data Exchange (ETDEWEB)

    2007-07-01

    The Norwegian Continental Shelf (NCS) is facing new challenges in reserve replacement and improved recovery in order to maintain the overall oil production rate from the area. A new target for an increase in oil reserves of 800 million Sm3 of oil (5 billion barrels) by year 2015 has been set by NPD. This is an ambitious goal considering several of the large fields are on a steep decline, and most of the recent discoveries are relatively small. A significant part of these increased reserves will have to come from fields currently on production, from reservoir areas that have been partly or fully swept, and it is therefore evident that Enhanced Oil Recovery (EOR) methods have to play a key role in achieving this target. EOR methods can be divided into gas based EOR methods and water based EOR methods. Thermal methods are not considered applicable on the NCS due to the relatively light oils present, and the depth of the reservoirs. Gas Based EOR; Water Based EOR; CO{sub 2} injection; Surfactants; Air injection; Polymer; Nitrogen injection; Alkaline; Flue gas injection; Polymer gels; WAG; MEOR; FAWAG. The former OG21 strategy document gave high priority to Water Alternating Gas (WAG) methods and CO{sub 2} injection for enhanced recovery. A lot of research and development and evaluation projects on CO{sub 2} injection were launched and are on-going, most of these are being CO{sub 2} WAG studies. The main challenge now in order to realize CO{sub 2} injection on the NCS is on CO{sub 2} availability and transport. It is also believed that increasing gas prices will limit the availability of hydrocarbon gas for injection purposes in the future. There is, however, a clear need for developing alternative cost efficient EOR methods that can improve the sweep efficiency significantly. Since a majority of the fields on the NCS are being produced under water flooding (or WAG), methods that can improve the water flooding efficiency by chemical additives are of special interest and

  4. 3D Endoscope to Boost Safety, Cut Cost of Surgery

    Science.gov (United States)

    2015-01-01

    Researchers at the Jet Propulsion Laboratory worked with the brain surgeon who directs the Skull Base Institute in Los Angeles to create the first endoscope fit for brain surgery and capable of producing 3D video images. It is also the first to be able to steer its lens back and forth. These improvements to visibility are expected to improve safety, speeding patient recovery and reducing medical costs.

  5. [Contrastive analysis of artifacts produced by metal dental crowns in 3.0 T magnetic resonance imaging with six sequences].

    Science.gov (United States)

    Lan, Gao; Yunmin, Lian; Pu, Wang; Haili, Huai

    2016-06-01

    This study aimed to observe and evaluate six 3.0 T sequences of metallic artifacts produced by metal dental crowns. Dental crowns fabricated with four different materials (Co-Gr, Ni-Gr, Ti alloy and pure Ti) were evaluated. A mature crossbreed dog was used as the experimental animal, and crowns were fabricated for its upper right second premolar. Each crown was examined through head MRI (3.0 T) with six sequences, namely, T₁ weighted-imaging of spin echo (T₁W/SE), T₂ weighted-imaging of inversion recovery (T₂W/IR), T₂ star gradient echo (T₂*/GRE), T2 weighted-imaging of fast spin echo (T₂W/FSE), T₁ weighted-imaging of fluid attenuate inversion recovery (T₂W/FLAIR), and T₂ weighted-imaging of propeller (T₂W/PROP). The largest area and layers of artifacts were assessed and compared. The artifact in the T₂*/GRE sequence was significantly wider than those in the other sequences (P 0.05). T₂*/GRE exhibit the strongest influence on the artifact, whereas the five other sequences contribute equally to artifact generation.

  6. Difficulty of MRI based identification of lesion age by acute infra-tentorial ischemic stroke.

    Directory of Open Access Journals (Sweden)

    Florian Grosse-Dresselhaus

    Full Text Available Systemic thrombolysis in acute ischemic stroke is restricted to the 4.5 h time window. Many patients are excluded from this treatment because symptom onset is unknown. Magnetic resonance imaging (MRI studies have shown that stroke patients presenting with acute supra-tentorial diffusion-weighted imaging (DWI lesions that do not have matching lesions on fluid attenuated inversion recovery (FLAIR are likely to be within a 4.5 hour time window. This study examines the DWI-FLAIR mismatch in infra-tentorial stroke.This was a retrospectively conducted substudy of the "1000+" study; a prospective, single-center observational study (http://clinicaltrials.gov; NCT00715533. Fifty-six patients with infra-tentorial stroke confirmed by MRI and known symptom onset who underwent the scan within 24 h after symptom onset were analysed. Two neurologists blinded to clinical information separately rated the DWI lesion visibility on FLAIR. Lesion volume, relative signal intensities of DWI and relative apparent diffusion coefficient values were determined.Regarding baseline characteristics our study population had a median age of 66 years, a median time from symptom onset to MRI of 616.5 minutes, a median NIHSS of 3 and a median DWI lesion volume of 0.26 ml. A negative FLAIR allocated patients to a time window under 4.5 h correctly with a sensitivity of 55% and a specificity of 61%, a positive predictive value of 44% and a negative predictive value of 71%. FLAIR positivity decreased with age (p = 0.018, and showed no significant correlation to lesion volume (p = 0.145.In our study the DWI-FLAIR-Mismatch does not help to reliably identify patients within 4.5 h of symptom onset in acute ischemic infra-tentorial stroke. Thus therapeutical decisions based on the DWI-FLAIR mismatch estimation of time from onset cannot be recommended in patients with infra-tentorial stroke.

  7. 3D-mallien muokkaus 3D-tulostamista varten CAD-ohjelmilla

    OpenAIRE

    Lehtimäki, Jarmo

    2013-01-01

    Insinöörityössäni käsitellään 3D-mallien tulostamista ja erityisesti 3D-mallien mallintamista niin, että kappaleiden valmistaminen 3D-tulostimella onnistuisi mahdollisimman hyvin. Työ tehtiin Prohoc Oy:lle, joka sijaitsee Vaasassa. 3D-tulostuspalveluun tuli jatkuvasti 3D-malleja, joiden tulostuksessa oli ongelmia. Työssäni tutkin näiden ongelmien syntyä ja tein ohjeita eri 3D-mallinnusohjelmille, joiden tarkoituksena on auttaa tekemään helpommin tulostettavia 3D-malleja. Työhön kuului myös et...

  8. 3D imaging, 3D printing and 3D virtual planning in endodontics.

    Science.gov (United States)

    Shah, Pratik; Chong, B S

    2018-03-01

    The adoption and adaptation of recent advances in digital technology, such as three-dimensional (3D) printed objects and haptic simulators, in dentistry have influenced teaching and/or management of cases involving implant, craniofacial, maxillofacial, orthognathic and periodontal treatments. 3D printed models and guides may help operators plan and tackle complicated non-surgical and surgical endodontic treatment and may aid skill acquisition. Haptic simulators may assist in the development of competency in endodontic procedures through the acquisition of psycho-motor skills. This review explores and discusses the potential applications of 3D printed models and guides, and haptic simulators in the teaching and management of endodontic procedures. An understanding of the pertinent technology related to the production of 3D printed objects and the operation of haptic simulators are also presented.

  9. Simultaneous determination of vitamins D2 and D3 by electrospray ionization LC/MS/MS in infant formula and adult nutritionals: First Action 2012.11.

    Science.gov (United States)

    Gilliland, Donald L; Black, Charles K; Denison, James E; Seipelt, Charles T; Baugh, Steve

    2013-01-01

    A method was developed for the analysis of vitamins D2 and D3 in a variety of nutritional products. To extract vitamins D2 and D3 from products containing substantial amounts of fat, a saponification with alcoholic potassium hydroxide is required to release the vitamin D. Trideuterium-labeled vitamin D is added to the sample prior to saponification, and quantitation is achieved using linear regression of the ratio of peak response for 2H3-D and vitamin D. Acceptable linearity was achieved between 0.6 and 27 microg/100 g with a correlation requirement of >0.999. The method detection limit of 0.02 microg/100 g was verified by spiking placebo products carried through the saponification and extraction steps of the method. At the quantitation limit (0.12 microg/100 g), the signal was easily distinguished from the background. Vitamin D3 spike recoveries ranged from 107 to 119% at the low level and 104 to 116% at the high-level spike. Vitamin D2 recoveries were 105 to 116% and 91 to 110% for the low- and high-level spikes, respectively. SRM 1849a has a certified concentration of 11.1 +/- 1.7 microg/100 g; using this standard reference material, the range of 9.4 to 12.8 microg/100 g was met on each of the 6 days. Method repeatability, determined in 12 vitamin D3 product matrixes over 6 days, ranged from 3.9 to 48%. The adult nutrition-milk protein sample was the most notable; it failed within-day, as well as day-to-day, precision requirements. There was no attempt to optimize the sample preparation to accommodate any problem matrix.

  10. Cognitive Function and 3-Tesla Magnetic Resonance Imaging Tractography of White Matter Hyperintensities in Elderly Persons

    Directory of Open Access Journals (Sweden)

    William Reginold

    2015-10-01

    Full Text Available Background/Aims: This study used 3-Tesla magnetic resonance imaging (MRI tractography to determine if there was an association between tracts crossing white matter hyperintensities (WMH and cognitive function in elderly persons. Methods: Brain T2-weighted fluid-attenuated inversion recovery (FLAIR and diffusion tensor MRI scans were acquired in participants above the age of 60 years. Twenty-six persons had WMH identified on T2 FLAIR scans. They completed a battery of neuropsychological tests and were classified as normal controls (n = 15 or with Alzheimer's dementia (n = 11. Tractography was generated by the Fiber Assignment by Continuous Tracking method. All tracts that crossed WMH were segmented. The average fractional anisotropy and average mean diffusivity of these tracts were quantified. We studied the association between cognitive test scores with the average mean diffusivity and average fractional anisotropy of tracts while controlling for age, total WMH volume and diagnosis. Results: An increased mean diffusivity of tracts crossing WMH was associated with worse performance on the Wechsler Memory Scale-III Longest Span Forward (p = 0.02. There was no association between the fractional anisotropy of tracts and performance on cognitive testing. Conclusion: The mean diffusivity of tracts crossing WMH measured by tractography is a novel correlate of performance on the Wechsler Memory Scale-III Longest Span Forward in elderly persons.

  11. A 3d-3d appetizer

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Du; Ye, Ke [Walter Burke Institute for Theoretical Physics, California Institute of Technology, Pasadena, CA, 91125 (United States)

    2016-11-02

    We test the 3d-3d correspondence for theories that are labeled by Lens spaces. We find a full agreement between the index of the 3d N=2 “Lens space theory” T[L(p,1)] and the partition function of complex Chern-Simons theory on L(p,1). In particular, for p=1, we show how the familiar S{sup 3} partition function of Chern-Simons theory arises from the index of a free theory. For large p, we find that the index of T[L(p,1)] becomes a constant independent of p. In addition, we study T[L(p,1)] on the squashed three-sphere S{sub b}{sup 3}. This enables us to see clearly, at the level of partition function, to what extent G{sub ℂ} complex Chern-Simons theory can be thought of as two copies of Chern-Simons theory with compact gauge group G.

  12. Serial MR observation of cortical laminar necrosis caused by brain infarction

    Energy Technology Data Exchange (ETDEWEB)

    Komiyama, M.; Nakajima, H.; Nishikawa, M.; Yasui, T. [Department of Neurosurgery, Osaka City General Hospital (Japan)

    1998-12-01

    To examine the chronological changes characteristic of cortical laminar necrosis caused by brain infarction, 16 patients were repeatedly examined using T1-, T2-weighted spin-echo, T2{sup *}-weighted gradient echo, fluid attenuated inversion recovery (FLAIR) images, and contrast enhanced T1-weighted images at 1.0 or 1.5 T. High intensity cortical lesions were visible on the T1-weighted images from 2 weeks after ictus and became prominent at 1 to 3 months, then became less apparent, but occasionally remained at high intensity for 2 years. High intensity cortical lesions on FLAIR images became prominent from 1 month, and then became less prominent from 1 year, but occasionally remained at high intensity for 2 years. Subcortical lesions did not display high intensity on T1-weighted images at any stage. On FLAIR images, subcortical lesions initially showed slightly high intensity and then low intensity from 6 months due to encephalomalacia. Cortical lesions showed prominent contrast enhancement from 2 weeks to 3 months, but subcortical lesions were prominent from 2 weeks only up to 1 month. T2*-weighted images disclosed haemosiderin in 3 of 7 patients, but there was no correlation with cortical short T1 lesions. Cortical laminar necrosis showed characteristic chronological signal changes on T1-weighted images and FLAIR images. Cortical short T1 lesions were found not to be caused by haemorrhagic infarction. (orig.) With 5 figs., 1 tab., 9 refs.

  13. Quasi 3D dosimetry (EPID, conventional 2D/3D detector matrices)

    International Nuclear Information System (INIS)

    Bäck, A

    2015-01-01

    Patient specific pretreatment measurement for IMRT and VMAT QA should preferably give information with a high resolution in 3D. The ability to distinguish complex treatment plans, i.e. treatment plans with a difference between measured and calculated dose distributions that exceeds a specified tolerance, puts high demands on the dosimetry system used for the pretreatment measurements and the results of the measurement evaluation needs a clinical interpretation. There are a number of commercial dosimetry systems designed for pretreatment IMRT QA measurements. 2D arrays such as MapCHECK ® (Sun Nuclear), MatriXX Evolution (IBA Dosimetry) and OCTAVIOUS ® 1500 (PTW), 3D phantoms such as OCTAVIUS ® 4D (PTW), ArcCHECK ® (Sun Nuclear) and Delta 4 (ScandiDos) and software for EPID dosimetry and 3D reconstruction of the dose in the patient geometry such as EPIDose TM (Sun Nuclear) and Dosimetry Check TM (Math Resolutions) are available. None of those dosimetry systems can measure the 3D dose distribution with a high resolution (full 3D dose distribution). Those systems can be called quasi 3D dosimetry systems. To be able to estimate the delivered dose in full 3D the user is dependent on a calculation algorithm in the software of the dosimetry system. All the vendors of the dosimetry systems mentioned above provide calculation algorithms to reconstruct a full 3D dose in the patient geometry. This enables analyzes of the difference between measured and calculated dose distributions in DVHs of the structures of clinical interest which facilitates the clinical interpretation and is a promising tool to be used for pretreatment IMRT QA measurements. However, independent validation studies on the accuracy of those algorithms are scarce. Pretreatment IMRT QA using the quasi 3D dosimetry systems mentioned above rely on both measurement uncertainty and accuracy of calculation algorithms. In this article, these quasi 3D dosimetry systems and their use in patient specific

  14. 3D-FT MRI of the facial nerve

    International Nuclear Information System (INIS)

    Girard, N.; Raybaud, C.; Poncet, M.

    1994-01-01

    Contrast-enhanced 3D-FT MRI of the intrapetrous facial nerve was obtained in 38 patients with facial nerve disease, using a 1.0 T magnet and fast gradient-echo acquisition sequences. Contiguous millimetric sections were obtained, which could be reformatted in any desired plane. Acutely ill patients, were examined within the first 2 months, included: 24 with Bell's palsy and 6 with other acute disorders (Herpes zoster, trauma, neuroma, meningeal metastasis, middle ear granuloma). Six patients investigated more than a year after the onset of symptoms included 3 with congenital cholesteatoma, 2 with neuromas and one with a chronic Bell's palsy. The lesion was found incidentally in two cases (a suspected neurofibroma and a presumed drop metastasis from an astrocytoma). Patients with tumours had nodular, focally-enhancing lesions, except for the leptomeningeal metastasis in which the enhancement was linear. Linear, diffuse contrast enhancement of the facial nerve was found in trauma, and in the patient with a middle ear granuloma. Of the 24 patients with an acute Bell's palsy 15 exhibited linear contrast enhancement of the facial nerve. Three of these were lost to follow-up, but correlation of clinical outcome and contrast enhancement showed that only 4 of the 11 patients who made a complete recovery and all 10 patients with incomplete recovery demonstrated enhancement. Possible explanations for these findings are suggested by pathological data from the literature. 3D-FT imaging of the facial nerve thus yields direct information about the of the nerve condition and defines the morphological abnormalities. It can also demonstrate contrast enhancement which seems to have some prognostic value in acute idiopathic Bell's palsy. (orig.)

  15. Bending, force recovery, and D-cones in origami inspired model geometries

    Science.gov (United States)

    Eldar, Theresa; Rozairo, Damith; Croll, Andrew B.

    The need for materials with advanced functionality has driven a considerable amount of modern materials science. One idea that has gained significant traction is combining of the ideas Origami and Kirigami with existing materials to build in advanced functionality. In most origami damage is induced in order to trap areas of high curvature in desirable locations in a material. However, the long term and dynamic consequences of local failure are largely unknown. In order to gauge the complex interplay of material properties, relaxation and failure in a set of model thin films, a series of bending and force recovery experiments were carried out. We focus on three materials; polydimethylsiloxane (PDMS), polycarbonate (PC), and polystyrene (PS) chosen for their varying responses to stress. We first measured the load bearing capacity of a single bend in each material, examining the force recovery of bends at various curvatures. Next we examined a doubly folded system in which a single developable cone was created in a similar manner. While the D-cone clearly has massive local consequences for each system, it plays an insignificant role in the system's overall behavior. Finally, we considered higher order combinations of d-cones, ridges and bends. AFOSR under the Young Investigator Program (FA9550-15-1-0168).

  16. Evaluation of 3D tensor tractography of pyramidal tract depicted by 3T MRI in patients with lacunar infarcts. For prediction of motor function outcome

    International Nuclear Information System (INIS)

    Igase, Keiji; Arai, Masamori; Matsubara, Ichiro; Goishi, Jyunji; Sadamoto, Kazuhiko; Kumon, Yoshiaki; Nagato, Shigeyuki; Seno, Toshimoto; Ohnishi, Takanori

    2007-01-01

    3D tensor tractography (DTT) has been applied to central nervous system (CNS) diseases to depict neuronal fibers. In this study with 3 tesla MRI, we have evaluated DTT to predict outcome of motor function in patients with lacunar infarcts. Fifteen patients with New lacunar infarcts, underwent DTTs with at least one in the acute (mean 1.4 days) and another in the subacute phase (mean 18.7 days). Patients were separated to 2 groups, recovery and non-recovery. Patients in former group had almost complete recovery in motor function 3 month later, while those to latter had a residual hemiparesis. Motor function was assessed with MMT score, which was uniquely stratefied into 12 levels by a modified MMT (manual muscle testing) protocol. DTT was implemented with 3 tesla MRI (Signa Excite; GE) and analyzed with dTV. IISR which was produced by the Department of Radiology, Tokyo University. The pyramidal tract was delineated by setting each region of interest (ROI), with the cerebral peduncle as the seed point and the motor cortex as the target point. The number of pyramidal fibers was identified as drawn lines obtained from a result display. The ratio of the number of fibers (RF) was calculated based on the number of fibers in the injured side relative to the number of fibers in the intact side x 100. In acute phase mean RFs the recovery (70.8±21.6%) and non-recovery (63.5±23.4%) groups were not significantly different. RF of recovery group in subacute phase was 100.5±28.3%, which was significantly higher with that in acute phase, meanwhile there was no significance difference between RFs of non-recovery group in two phases. In addition there was a significant correlation (R 2 =0.89) between MMT score 3 month later and RF in subacute phase in all patients group. There seems to be a correlation between long-term recovery of motor function and increased numbers in pyramidal fibers defected by DTT. Therefore, DTT may have a potential use in predicting the outcome of patients

  17. 3D MR cisternography to identify distal dural rings. Comparison of 3D-CISS and 3D-SPACE sequences

    International Nuclear Information System (INIS)

    Watanabe, Yoshiyuki; Makidono, Akari; Nakamura, Miho; Saida, Yukihisa

    2011-01-01

    The distal dural ring (DDR) is an anatomical landmark used to distinguish intra- and extradural aneurysms. We investigated identification of the DDR using 2 three-dimensional (3D) magnetic resonance (MR) cisternography sequences-3D constructive interference in steady state (CISS) and 3D sampling perfection with application optimized contrasts using different flip angle evolutions (SPACE)-at 3.0 tesla. Ten healthy adult volunteers underwent imaging with 3D-CISS, 3D-SPACE, and time-of-flight (TOF) MR angiography (TOF-MRA) sequences at 3.0T. We analyzed DDR identification and internal carotid artery (ICA) signal intensity and classified the shape of the carotid cave. We identified the DDR using both 3D-SPACE and 3D-CISS, with no significant difference between the sequences. Visualization of the outline of the ICA in the cavernous sinus (CS) was significantly clearer with 3D-SPACE than 3D-CISS. In the CS and petrous portions, signal intensity was lower with 3D-SPACE, and the flow void was poor with 3D-CISS in some subjects. We identified the DDR with both 3D-SPACE and 3D-CISS, but the superior contrast of the ICA in the CS using 3D-SPACE suggests the superiority of this sequence for evaluating the DDR. (author)

  18. 3D video

    CERN Document Server

    Lucas, Laurent; Loscos, Céline

    2013-01-01

    While 3D vision has existed for many years, the use of 3D cameras and video-based modeling by the film industry has induced an explosion of interest for 3D acquisition technology, 3D content and 3D displays. As such, 3D video has become one of the new technology trends of this century.The chapters in this book cover a large spectrum of areas connected to 3D video, which are presented both theoretically and technologically, while taking into account both physiological and perceptual aspects. Stepping away from traditional 3D vision, the authors, all currently involved in these areas, provide th

  19. 3D composite image, 3D MRI, 3D SPECT, hydrocephalus

    International Nuclear Information System (INIS)

    Mito, T.; Shibata, I.; Sugo, N.; Takano, M.; Takahashi, H.

    2002-01-01

    The three-dimensional (3D)SPECT imaging technique we have studied and published for the past several years is an analytical tool that permits visual expression of the cerebral circulation profile in various cerebral diseases. The greatest drawback of SPECT is that the limitation on precision of spacial resolution makes intracranial localization impossible. In 3D SPECT imaging, intracranial volume and morphology may vary with the threshold established. To solve this problem, we have produced complimentarily combined SPECT and helical-CT 3D images by means of general-purpose visualization software for intracranial localization. In hydrocephalus, however, the key subject to be studied is the profile of cerebral circulation around the ventricles of the brain. This suggests that, for displaying the cerebral ventricles in three dimensions, CT is a difficult technique whereas MRI is more useful. For this reason, we attempted to establish the profile of cerebral circulation around the cerebral ventricles by the production of combined 3D images of SPECT and MRI. In patients who had shunt surgery for hydrocephalus, a difference between pre- and postoperative cerebral circulation profiles was assessed by a voxel distribution curve, 3D SPECT images, and combined 3D SPECT and MRI images. As the shunt system in this study, an Orbis-Sigma valve of the automatic cerebrospinal fluid volume adjustment type was used in place of the variable pressure type Medos valve currently in use, because this device requires frequent changes in pressure and a change in pressure may be detected after MRI procedure. The SPECT apparatus used was PRISM3000 of the three-detector type, and 123I-IMP was used as the radionuclide in a dose of 222 MBq. MRI data were collected with an MAGNEXa+2 with a magnetic flux density of 0.5 tesla under the following conditions: field echo; TR 50 msec; TE, 10 msec; flip, 30ueK; 1 NEX; FOV, 23 cm; 1-mm slices; and gapless. 3D images are produced on the workstation TITAN

  20. 3D Printing and 3D Bioprinting in Pediatrics.

    Science.gov (United States)

    Vijayavenkataraman, Sanjairaj; Fuh, Jerry Y H; Lu, Wen Feng

    2017-07-13

    Additive manufacturing, commonly referred to as 3D printing, is a technology that builds three-dimensional structures and components layer by layer. Bioprinting is the use of 3D printing technology to fabricate tissue constructs for regenerative medicine from cell-laden bio-inks. 3D printing and bioprinting have huge potential in revolutionizing the field of tissue engineering and regenerative medicine. This paper reviews the application of 3D printing and bioprinting in the field of pediatrics.

  1. 3D Printing and 3D Bioprinting in Pediatrics

    OpenAIRE

    Vijayavenkataraman, Sanjairaj; Fuh, Jerry Y H; Lu, Wen Feng

    2017-01-01

    Additive manufacturing, commonly referred to as 3D printing, is a technology that builds three-dimensional structures and components layer by layer. Bioprinting is the use of 3D printing technology to fabricate tissue constructs for regenerative medicine from cell-laden bio-inks. 3D printing and bioprinting have huge potential in revolutionizing the field of tissue engineering and regenerative medicine. This paper reviews the application of 3D printing and bioprinting in the field of pediatrics.

  2. A microfluidic device for 2D to 3D and 3D to 3D cell navigation

    International Nuclear Information System (INIS)

    Shamloo, Amir; Amirifar, Leyla

    2016-01-01

    Microfluidic devices have received wide attention and shown great potential in the field of tissue engineering and regenerative medicine. Investigating cell response to various stimulations is much more accurate and comprehensive with the aid of microfluidic devices. In this study, we introduced a microfluidic device by which the matrix density as a mechanical property and the concentration profile of a biochemical factor as a chemical property could be altered. Our microfluidic device has a cell tank and a cell culture chamber to mimic both 2D to 3D and 3D to 3D migration of three types of cells. Fluid shear stress is negligible on the cells and a stable concentration gradient can be obtained by diffusion. The device was designed by a numerical simulation so that the uniformity of the concentration gradients throughout the cell culture chamber was obtained. Adult neural cells were cultured within this device and they showed different branching and axonal navigation phenotypes within varying nerve growth factor (NGF) concentration profiles. Neural stem cells were also cultured within varying collagen matrix densities while exposed to NGF concentrations and they experienced 3D to 3D collective migration. By generating vascular endothelial growth factor concentration gradients, adult human dermal microvascular endothelial cells also migrated in a 2D to 3D manner and formed a stable lumen within a specific collagen matrix density. It was observed that a minimum absolute concentration and concentration gradient were required to stimulate migration of all types of the cells. This device has the advantage of changing multiple parameters simultaneously and is expected to have wide applicability in cell studies. (paper)

  3. Is the type and extent of hippocampal sclerosis measurable on high-resolution MRI?

    Energy Technology Data Exchange (ETDEWEB)

    Urbach, H; Schwarzwald, R [Medical Center University of Freiburg, Dept. of Neuroradiology, Freiburg (Germany); Huppertz, H.J. [Swiss Epilepsy Center, Zurich (Switzerland); Becker, A.J. [Medical Center University of Bonn, Department of Neuropathology, Bonn (Germany); Wagner, J. [Medical Center University of Bonn, Department of Epileptology, Bonn (Germany); Bahri, M. Delsous; Tschampa, H.J. [Medical Center University of Bonn, Department of Radiology/Neuroradiology, Bonn (Germany)

    2014-09-15

    The purpose of this study is to relate hippocampal volume and FLAIR signal intensity to Wyler grading of hippocampal sclerosis (HS). Of 100 consecutive patients with temporal lobe epilepsy and HS as histopathological diagnosis, 32 had high-resolution 3 Tesla MRI and anatomically well-preserved hippocampi following amygdalo-hippocampectomy. Hippocampal volume on 3D T1-weighted gradient echo and signal intensity on coronal FLAIR sequences were determined using FreeSurfer and SPM tools and related to Wyler grading. Seizure outcome was determined after 1 year. Histopathology showed four Wyler II, 19 Wyler III, and 9 Wyler IV HS. Hippocampal volumes were 3.08 ml for Wyler II (Wyler II/contralateral side: p > 0.05), 2.19 ml for Wyler III (p < 0.01), 2.62 ml for Wyler IV (p = 0.01), and 3.08 ml for the contralateral side. Normalized FLAIR signals were 1,354 (p = 0.0004), 1,408 (p < 0.0001), 1,371 (p < 0.04), and 1,296, respectively. Wyler II hippocampi were visually normal. Two of four (50 %) Wyler II, 16/19 (84 %) Wyler III, and 6/9 (66 %) Wyler IV patients achieved Engel I outcome. Combined volumetry and quantitative FLAIR signal analysis clearly identifies Wyler III and IV HS. Quantitative FLAIR signal analysis may be helpful to identify Wyler II HS. (orig.)

  4. Comparison of 3- and 20-Gradient Direction Diffusion-Weighted Imaging in a Clinical Subacute Cohort of Patients with Transient Ischemic Attack

    DEFF Research Database (Denmark)

    Havsteen, Inger; Ovesen, Christian; Willer, Lasse

    2017-01-01

    Objective: Diffusion tensor imaging may aid brain ischemia assessment but is more time consuming than conventional diffusion-weighted imaging (DWI). We compared 3-gradient direction DWI (3DWI) and 20-gradient direction DWI (20DWI) standard vendor protocols in a hospital-based prospective cohort...... of patients with transient ischemic attack (TIA) for lesion detection, lesion brightness, predictability of persisting infarction, and final infarct size. Methods: We performed 3T-magnetic resonance imaging including diffusion and T2-fluid attenuated inversion recovery (FLAIR) within 72 h and 8 weeks after...... uniquely 20DWI positive. 3DWI was visually brightest for 34 lesions. 12 lesions were brightest on 20DWI. The median 3DWI lesion area was larger for lesions equally bright, or brightest on 20DWI [median (IQR) 39 (18-95) versus 18 (10-34) mm2, P = 0.007]. 3DWI showed highest measured relative lesion signal...

  5. 3D game environments create professional 3D game worlds

    CERN Document Server

    Ahearn, Luke

    2008-01-01

    The ultimate resource to help you create triple-A quality art for a variety of game worlds; 3D Game Environments offers detailed tutorials on creating 3D models, applying 2D art to 3D models, and clear concise advice on issues of efficiency and optimization for a 3D game engine. Using Photoshop and 3ds Max as his primary tools, Luke Ahearn explains how to create realistic textures from photo source and uses a variety of techniques to portray dynamic and believable game worlds.From a modern city to a steamy jungle, learn about the planning and technological considerations for 3D modelin

  6. Plasma and milk concentrations of vitamin D3 and 25-hydroxy vitamin D3 following intravenous injection of vitamin D3 or 25-hydroxy vitamin D3.

    OpenAIRE

    Hidiroglou, M; Knipfel, J E

    1984-01-01

    Plasma levels of vitamin D3 or 25-hydroxyvitamin D3 in ewes after administration of a single massive intravenous dose of vitamin D3 (2 X 10(6) IU) or 25-hydroxy vitamin D3 (5 mg) were determined at zero, one, two, three, five, ten and 20 days postinjection. In six ewes injected with vitamin D3 conversion of vitamin D3 to 25-hydroxy vitamin D3 resulted in a six-fold increase in the plasma 25-hydroxy vitamin D3 level within one day. Elevated levels were maintained until day 10 but by day 20 a s...

  7. Revised Recommendations of the Consortium of MS Centers Task Force for a Standardized MRI Protocol and Clinical Guidelines for the Diagnosis and Follow-Up of Multiple Sclerosis

    Science.gov (United States)

    Traboulsee, A.; Simon, J.H.; Stone, L.; Fisher, E.; Jones, D.E.; Malhotra, A.; Newsome, S.D.; Oh, J.; Reich, D.S.; Richert, N.; Rammohan, K.; Khan, O.; Radue, E.-W.; Ford, C.; Halper, J.; Li, D.

    2016-01-01

    SUMMARY An international group of neurologists and radiologists developed revised guidelines for standardized brain and spinal cord MR imaging for the diagnosis and follow-up of MS. A brain MR imaging with gadolinium is recommended for the diagnosis of MS. A spinal cord MR imaging is recommended if the brain MR imaging is nondiagnostic or if the presenting symptoms are at the level of the spinal cord. A follow-up brain MR imaging with gadolinium is recommended to demonstrate dissemination in time and ongoing clinically silent disease activity while on treatment, to evaluate unexpected clinical worsening, to re-assess the original diagnosis, and as a new baseline before starting or modifying therapy. A routine brain MR imaging should be considered every 6 months to 2 years for all patients with relapsing MS. The brain MR imaging protocol includes 3D T1-weighted, 3D T2-FLAIR, 3D T2-weighted, post-single-dose gadolinium-enhanced T1-weighted sequences, and a DWI sequence. The progressive multifocal leukoencephalopathy surveillance protocol includes FLAIR and DWI sequences only. The spinal cord MR imaging protocol includes sagittal T1-weighted and proton attenuation, STIR or phase-sensitive inversion recovery, axial T2- or T2*-weighted imaging through suspicious lesions, and, in some cases, postcontrast gadolinium-enhanced T1-weighted imaging. The clinical question being addressed should be provided in the requisition for the MR imaging. The radiology report should be descriptive, with results referenced to previous studies. MR imaging studies should be permanently retained and available. The current revision incorporates new clinical information and imaging techniques that have become more available. PMID:26564433

  8. Studies on the analysis of 25-hydroxyvitamin D3 by isotope-dilution liquid chromatography–tandem mass spectrometry using enzyme-assisted derivatisation

    International Nuclear Information System (INIS)

    Abdel-Khalik, Jonas; Crick, Peter J.; Carter, Graham D.; Makin, Hugh L.; Wang, Yuqin; Griffiths, William J.

    2014-01-01

    Highlights: • New method for the analysis of 25-hydroxyvitamin D 3 exploiting Girard P derivatisation. • Method also applicable to vitamin D 3 , 1α,25- and 24,25-dihydroxyvitamin D 3 . • By modification of the method 3-epi-25-hydroxyvitamin D 3 can also be analysed. - Abstract: The total serum concentration of 25-hydroxyvitamins D (25-hydroxyvitamin D 3 and 25-hydroxyvitamin D 2 ) is currently used as an indicator of vitamins D status. Vitamins D insufficiency is claimed to be associated with multiple diseases, thus accurate and precise reference methods for the quantification of 25-hydroxyvitamins D are needed. Here we present a novel enzyme-assisted derivatisation method for the analysis of vitamins D metabolites in adult serum utilising 25-[26,26,26,27,27,27- 2 H 6 ]hydroxyvitamin D 3 as the internal standard. Extraction of 25-hydroxyvitamins D from serum is performed with acetonitrile, which is shown to be more efficient than ethanol. Cholesterol oxidase is used to oxidize the 3β-hydroxy group in the vitamins D metabolites followed by derivatisation of the newly formed 3-oxo group with Girard P reagent. 17β-Hydroxysteroid dehydrogenase type 10 is shown to oxidize selectively the 3α-hydroxy group in the 3α-hydroxy epimer of 25-hydroxyvitamin D 3 . Quantification is achieved by isotope-dilution liquid chromatography–tandem mass spectrometry. Recovery experiments for 25-hydroxyvitamin D 3 performed on adult human serum give recovery of 102–106%. Furthermore in addition to 25-hydroxyvitamin D 3 , 24,25-dihydroxyvitamin D 3 and other uncharacterised dihydroxy metabolites, were detected in adult human serum

  9. 3-D Whole-Core Transport Calculation with 3D/2D Rotational Plane Slicing Method

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Han Jong; Cho, Nam Zin [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2014-10-15

    Use of the method of characteristics (MOC) is very popular due to its capability of heterogeneous geometry treatment and widely used for 2-D core calculation, but direct extension of MOC to 3-D core is not so attractive due to huge calculational cost. 2-D/1-D fusion method was very successful for 3-D calculation of current generation reactor types (highly heterogeneous in radial direction but piece-wise homogeneous in axial direction). In this paper, 2-D MOC concept is extended to 3-D core calculation with little modification of an existing 2-D MOC code. The key idea is to suppose 3-D geometry as a set of many 2-D planes like a phone-directory book. Dividing 3-D structure into a large number of 2-D planes and solving each plane with a simple 2-D SN transport method would give the solution of a 3-D structure. This method was developed independently at KAIST but it is found that this concept is similar with that of 'plane tracing' in the MCCG-3D code. The method developed was tested on the 3-D C5G7 OECD/NEA benchmark problem and compared with the 2-D/1-D fusion method. Results show that the proposed method is worth investigating further. A new approach to 3-D whole-core transport calculation is described and tested. By slicing 3-D structure along characteristic planes and solving each 2-D plane problem, we can get 3-D solution. The numerical test results indicate that the new method is comparable with the 2D/1D fusion method and outperforms other existing methods. But more fair comparison should be done in similar discretization level.

  10. Stress recovery techniques for natural element method in 2-D solid mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jin Rae [Dept. of Naval Architecture and Ocean Engineering, Hongik University, Sejong (Korea, Republic of)

    2016-11-15

    This paper is concerned with the stress recovery for the natural element method in which the problem domain is discretized with Delaunay triangles and the structural behavior is approximated with Laplace interpolation functions. Basically, the global and local patch recovery techniques based on the L2-projection method are adopted. For the local patch recovery, the local element patches are defined by the supports of each Laplace interpolation function. For the comparison purpose, the local stress recovery is also performed using Lagrange-type basis functions that are used for 3- and 6-node triangular elements. The stresses that are recovered by the present global and local recovery techniques are compared each other and compared with the available analytic solution, in terms of their spatial distributions and the convergence rates. As well, the dependence of the recovered stress field on the type of test basis functions that are used forbnov-Galerkin (BG) and Petrov-Galerkin (PG) natural element methods is also investigated.

  11. From 2D to 3D turbulence through 2D3C configurations

    Science.gov (United States)

    Buzzicotti, Michele; Biferale, Luca; Linkmann, Moritz

    2017-11-01

    We study analytically and numerically the geometry of the nonlinear interactions and the resulting energy transfer directions of 2D3C flows. Through a set of suitably designed Direct Numerical Simulations we also study the coupling between several 2D3C flows, where we explore the transition between 2D and fully 3D turbulence. In particular, we find that the coupling of three 2D3C flows on mutually orthogonal planes subject to small-scale forcing leads to a stationary 3D out-of-equilibrium dynamics at the energy containing scales where the inverse cascade is directly balanced by a forward cascade carried by a different subsets of interactions. ERC AdG Grant No 339032 NewTURB.

  12. 3D Space Shift from CityGML LoD3-Based Multiple Building Elements to a 3D Volumetric Object

    Directory of Open Access Journals (Sweden)

    Shen Ying

    2017-01-01

    Full Text Available In contrast with photorealistic visualizations, urban landscape applications, and building information system (BIM, 3D volumetric presentations highlight specific calculations and applications of 3D building elements for 3D city planning and 3D cadastres. Knowing the precise volumetric quantities and the 3D boundary locations of 3D building spaces is a vital index which must remain constant during data processing because the values are related to space occupation, tenure, taxes, and valuation. To meet these requirements, this paper presents a five-step algorithm for performing a 3D building space shift. This algorithm is used to convert multiple building elements into a single 3D volumetric building object while maintaining the precise volume of the 3D space and without changing the 3D locations or displacing the building boundaries. As examples, this study used input data and building elements based on City Geography Markup Language (CityGML LoD3 models. This paper presents a method for 3D urban space and 3D property management with the goal of constructing a 3D volumetric object for an integral building using CityGML objects, by fusing the geometries of various building elements. The resulting objects possess true 3D geometry that can be represented by solid geometry and saved to a CityGML file for effective use in 3D urban planning and 3D cadastres.

  13. Proteomics of post-irradiation recovery in D. radiodurans

    International Nuclear Information System (INIS)

    Basu, Bhakti; Apte, Shree Kumar

    2012-01-01

    An extremophile Deinococcus radiodurans is bestowed with an extraordinary DNA repair ability that renders it virtually resistant to all known forms of DNA damage caused by ionizing radiations (10 kGy of gamma rays), UV (1 kJ/m 2 ) or weeks of desiccation etc. The genome of D. radiodurans encodes a unique combination of DNA repair pathways such as prokaryotic type RecFOR mediated homologous recombination (HR) and nucleotide/base excision repair along with eukaryotic type strand annealing (SA) and non-homologous end joining (NHEJ), but is devoid of universal prokaryotic DNA repair pathways such as RecBCD mediated HR, photo-reactivation and SOS response. Collective evidence obtained so far from multiple approaches, have indicated (i) that all genes essential for DNA repair are not necessarily induced following radiation stress (ii) early RecA independent DNA assembly occurs, and (iii) absolute necessity of RecA dependent HR for final genome restitution. The 6 kGy gamma irradiation inducible proteome dynamics were mapped during the post-irradiation growth arrest phase by 2D protein electrophoresis coupled with mass spectrometry. Radiation inducible expression of at least 33 proteins was evident in the first 1h of post irradiation recovery

  14. Federal role in resource recovery will focus on waste-to-energy R and D

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, R.A.

    1981-05-01

    Virtually all of the federal programs created in recent years to sponsor resource recovery R and D have been slated for budget cuts or termination by the administration of President Ronald Reagan. The only programs that will survive revised fiscal budgets will be waste-to-energy R and D studies sponsored by DOE and EPA. Differing reactions to such cuts are apparent: the affected agencies are protesting, while private industry welcomes this hands-off policy.

  15. 3D-FT MRI of the facial nerve

    Energy Technology Data Exchange (ETDEWEB)

    Girard, N. (Neuroradiology, Hopital Nord, 13 Marseille (France)); Raybaud, C. (Neuroradiology, Hopital Nord, 13 Marseille (France)); Poncet, M. (Neuroradiology, Hopital Nord, 13 Marseille (France))

    1994-08-01

    Contrast-enhanced 3D-FT MRI of the intrapetrous facial nerve was obtained in 38 patients with facial nerve disease, using a 1.0 T magnet and fast gradient-echo acquisition sequences. Contiguous millimetric sections were obtained, which could be reformatted in any desired plane. Acutely ill patients, were examined within the first 2 months, included: 24 with Bell's palsy and 6 with other acute disorders (Herpes zoster, trauma, neuroma, meningeal metastasis, middle ear granuloma). Six patients investigated more than a year after the onset of symptoms included 3 with congenital cholesteatoma, 2 with neuromas and one with a chronic Bell's palsy. The lesion was found incidentally in two cases (a suspected neurofibroma and a presumed drop metastasis from an astrocytoma). Patients with tumours had nodular, focally-enhancing lesions, except for the leptomeningeal metastasis in which the enhancement was linear. Linear, diffuse contrast enhancement of the facial nerve was found in trauma, and in the patient with a middle ear granuloma. Of the 24 patients with an acute Bell's palsy 15 exhibited linear contrast enhancement of the facial nerve. Three of these were lost to follow-up, but correlation of clinical outcome and contrast enhancement showed that only 4 of the 11 patients who made a complete recovery and all 10 patients with incomplete recovery demonstrated enhancement. Possible explanations for these findings are suggested by pathological data from the literature. 3D-FT imaging of the facial nerve thus yields direct information about the of the nerve condition and defines the morphological abnormalities. It can also demonstrate contrast enhancement which seems to have some prognostic value in acute idiopathic Bell's palsy. (orig.)

  16. Recovery in aluminium

    DEFF Research Database (Denmark)

    Gundlach, Carsten

    2006-01-01

    In the present thesis the development of a unique experimental method for volume characterisation of individual embedded crystallites down to a radius of 150 nm is presented. This method is applied to in-situ studies of recovery in aluminium. The method is an extension of 3DXRD microscopy, an X...... are represented as strings. To identify the strings a combination of a 5D connected component type algorithm and multi-peak fitting was found to be superior. The first use of the method was a study of recovery of a deformed aluminium alloy (AA1050). The aluminium alloy was deformed by cold rolling to a thickness...

  17. Contribution of a natural polymorphism, protein kinase G, modulates electroconvulsive seizure recovery in D. melanogaster.

    Science.gov (United States)

    Kelly, Stephanie P; Risley, Monica G; Miranda, Leonor E; Dawson-Scully, Ken

    2018-05-24

    Drosophila melanogaster is a well-characterized model for neurological disorders and is widely used for investigating causes of altered neuronal excitability leading to seizure-like behavior. One method used to analyze behavioral output of neuronal perturbance is recording the time to locomotor recovery from an electroconvulsive shock. Based on this behavior, we sought to quantify seizure susceptibility in larval D. melanogaster with differences in the enzymatic activity levels of a major protein, cGMP-dependent protein kinase (PKG). PKG, encoded by foraging , has two natural allelic variants and has previously been implicated in several important physiological characteristics including: foraging patterns, learning and memory, and environmental stress tolerance. The well-established NO/cGMP/PKG signaling pathway found in the fly, which potentially targets downstream K + channel(s), which ultimately impacts membrane excitability; leading to our hypothesis: altering PKG enzymatic activity modulates time to recovery from an electroconvulsive seizure. Our results show that by both genetically and pharmacologically increasing PKG enzymatic activity, we can decrease the locomotor recovery time from an electroconvulsive seizure in larval D. melanogaster . © 2018. Published by The Company of Biologists Ltd.

  18. RAG-3D: a search tool for RNA 3D substructures

    Science.gov (United States)

    Zahran, Mai; Sevim Bayrak, Cigdem; Elmetwaly, Shereef; Schlick, Tamar

    2015-01-01

    To address many challenges in RNA structure/function prediction, the characterization of RNA's modular architectural units is required. Using the RNA-As-Graphs (RAG) database, we have previously explored the existence of secondary structure (2D) submotifs within larger RNA structures. Here we present RAG-3D—a dataset of RNA tertiary (3D) structures and substructures plus a web-based search tool—designed to exploit graph representations of RNAs for the goal of searching for similar 3D structural fragments. The objects in RAG-3D consist of 3D structures translated into 3D graphs, cataloged based on the connectivity between their secondary structure elements. Each graph is additionally described in terms of its subgraph building blocks. The RAG-3D search tool then compares a query RNA 3D structure to those in the database to obtain structurally similar structures and substructures. This comparison reveals conserved 3D RNA features and thus may suggest functional connections. Though RNA search programs based on similarity in sequence, 2D, and/or 3D structural elements are available, our graph-based search tool may be advantageous for illuminating similarities that are not obvious; using motifs rather than sequence space also reduces search times considerably. Ultimately, such substructuring could be useful for RNA 3D structure prediction, structure/function inference and inverse folding. PMID:26304547

  19. Determination of the 3d34d and 3d35s configurations of Fe V

    International Nuclear Information System (INIS)

    Azarov, V.I.

    2001-01-01

    The analysis of the spectrum of four times ionized iron, Fe V, has led to the determination of the 3d 3 4d and 3d 3 5s configurations. From 975 classified lines in the region 645-1190 A we have established 123 of 168 theoretically possible 3d 3 4d levels and 26 of 38 possible 3d 3 5s levels. The estimated accuracy of values of energy levels of these two configurations is about 0.7 cm -1 and 1.0 cm -1 , respectively. The level structure of the system of the 3d 4 , 3d 3 4s, 3d 3 4d and 3d 3 5s configurations has been theoretically interpreted and the energy parameters have been determined by a least squares fit to the observed levels. A comparison of parameters in Cr III and Fe V ions is given. (orig.)

  20. Axionic D3-D7 Inflation

    CERN Document Server

    Burgess, C P; Postma, M

    2009-01-01

    We study the motion of a D3 brane moving within a Type IIB string vacuum compactified to 4D on K3 x T_2/Z_2 in the presence of D7 and O7 planes. We work within the effective 4D supergravity describing how the mobile D3 interacts with the lightest bulk moduli of the compactification, including the effects of modulus-stabilizing fluxes. We seek inflationary solutions to the resulting equations, performing our search numerically in order to avoid resorting to approximate parameterizations of the low-energy potential. We consider uplifting from D-terms and from the supersymmetry-breaking effects of anti-D3 branes. We find examples of slow-roll inflation (with anti-brane uplifting) with the mobile D3 moving along the toroidal directions, falling towards a D7-O7 stack starting from the antipodal point. The inflaton turns out to be a linear combination of the brane position and the axionic partner of the K3 volume modulus, and the similarity of the potential along the inflaton direction with that of racetrack inflat...

  1. Heart rate recovery in elite Spanish male athletes.

    Science.gov (United States)

    Peinado, A B; Benito, P J; Barriopedro, M; Lorenzo, I; Maffulli, N; Calderón, F J

    2014-06-01

    During postexercise recovery, heart rate (HR) initially falls rapidly, followed by a period of slower decrease, until resting values are reached. The aim of the present work was to examine the differences in the recovery heart rate (RHR) between athletes engaged in static and dynamic sports. The study subjects were 294 federated sportsmen competing at the national and international level in sports classified using the criteria of Mitchell et al. as either prevalently static (N.=89) or prevalently dynamic (N.=205). Within the dynamic group, the subjects who practised the most dynamic sports were assigned to further subgroups: triathlon (N.=20), long distance running (N.=58), cycling (N.=28) and swimming (N.=12). All athletes were subjected to a maximum exertion stress test and their HR recorded at 1, 2, 3 and 4 min (RHR1,2,3,4) into the HR recovery period. The following indices of recovery (IR) were then calculated: IR1=(HRpeak-RHR1,2,3,4)/(HRmax-HRrest)*100, IR2=(HRpeak-RHR1,2,3,4)/(HRmax/HRpeak), and IR3=HRpeak-RHR1,2,3,4. The differences in the RHR and IR for the static and dynamic groups were examined using two way ANOVA. The RHR at minutes 2 (138.7±15.2 vs. 134.8±14.4 beats·min⁻¹) and 3 (128.5±15.2 vs. 123.3±14.4 beats·min⁻¹) were significantly higher for the static group (Group S) than the dynamic group (Group D), respectively. Significant differences were seen between Group D and S with respect to IR1 at minutes 1 (26.4±8.7 vs. 24.8±8.4%), 2 (43.8±8.1 vs. 41.5±7.8%), 3 (52.1±8.3 vs. 49.1±8%) and 4 (56.8±8.6 vs. 55.4±7.4%) of recovery. For IR2, significant differences were seen between the same groups at minutes 2 (59.7±12.5 vs. 55.9±10.8 beats·min⁻¹) and 3 (71.0±13.5 vs. 66.1±11.4 beats·min⁻¹) of recovery. Finally, for IR3, the only significant difference between Group D and S was recorded at minute 3 of recovery (72.2±12.5 vs. 66.2±11.5 beats·min⁻¹). This work provides information on RHR of a large population of elite

  2. 3D Volume Rendering and 3D Printing (Additive Manufacturing).

    Science.gov (United States)

    Katkar, Rujuta A; Taft, Robert M; Grant, Gerald T

    2018-07-01

    Three-dimensional (3D) volume-rendered images allow 3D insight into the anatomy, facilitating surgical treatment planning and teaching. 3D printing, additive manufacturing, and rapid prototyping techniques are being used with satisfactory accuracy, mostly for diagnosis and surgical planning, followed by direct manufacture of implantable devices. The major limitation is the time and money spent generating 3D objects. Printer type, material, and build thickness are known to influence the accuracy of printed models. In implant dentistry, the use of 3D-printed surgical guides is strongly recommended to facilitate planning and reduce risk of operative complications. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. 3D object-oriented image analysis in 3D geophysical modelling

    DEFF Research Database (Denmark)

    Fadel, I.; van der Meijde, M.; Kerle, N.

    2015-01-01

    Non-uniqueness of satellite gravity interpretation has traditionally been reduced by using a priori information from seismic tomography models. This reduction in the non-uniqueness has been based on velocity-density conversion formulas or user interpretation of the 3D subsurface structures (objects......) based on the seismic tomography models and then forward modelling these objects. However, this form of object-based approach has been done without a standardized methodology on how to extract the subsurface structures from the 3D models. In this research, a 3D object-oriented image analysis (3D OOA......) approach was implemented to extract the 3D subsurface structures from geophysical data. The approach was applied on a 3D shear wave seismic tomography model of the central part of the East African Rift System. Subsequently, the extracted 3D objects from the tomography model were reconstructed in the 3D...

  4. Optical Coherence Tomography Noise Reduction Using Anisotropic Local Bivariate Gaussian Mixture Prior in 3D Complex Wavelet Domain

    OpenAIRE

    Rabbani, Hossein; Sonka, Milan; Abramoff, Michael D.

    2013-01-01

    In this paper, MMSE estimator is employed for noise-free 3D OCT data recovery in 3D complex wavelet domain. Since the proposed distribution for noise-free data plays a key role in the performance of MMSE estimator, a priori distribution for the pdf of noise-free 3D complex wavelet coefficients is proposed which is able to model the main statistical properties of wavelets. We model the coefficients with a mixture of two bivariate Gaussian pdfs with local parameters which are able to capture th...

  5. Fast response of carbon monoxide gas sensors using a highly porous network of ZnO nanoparticles decorated on 3D reduced graphene oxide

    Science.gov (United States)

    Ha, Nguyen Hai; Thinh, Dao Duc; Huong, Nguyen Thanh; Phuong, Nguyen Huy; Thach, Phan Duy; Hong, Hoang Si

    2018-03-01

    Zinc oxide (ZnO) nanoparticles loaded onto 3D reduced graphene oxide (3D-RGO) for carbon monoxide (CO) sensing were synthesized using hydrothermal method. The highly porous ZnO/3D-RGO configuration was stable without collapsing and was deposited on the micro-heater of the CO gas sensor. The resulting CO gas sensor displayed high sensitivity, fast response/recovery, and good linearity. The sensor achieved a response value of 85.2% for 1000 ppm CO at a working temperature of 200 °C. The response and recovery times of the sensor were 7 and 9 s for 1000 ppm CO at 200 °C. Similarly, the response value, response time, and recovery time of the sensor at room temperature were 27.5%, 14 s, and 15 s, respectively. The sensor demonstrated a distinct response to various CO concentrations in the range of 1-1000 ppm and good selectivity toward CO gas. In addition, the sensor exhibited good repeatability in multi-cycle and long-term stability.

  6. Methane production, recovery and emission from two Danish landfills

    DEFF Research Database (Denmark)

    Fathi Aghdam, Ehsan

    ) an in-depth investigation of CH4 production from shredder waste (SW) at landfills, 2) the determination of gas recovery efficiency at two adjacent Danish landfills by field measurement, and 3) the influence of meteorological parameters on gas recovery from landfills. This PhD project focused on two......Landfill gas (LFG), mainly consisting of methane (CH4) and carbon dioxide (CO2), is produced by the anaerobic digestion of biodegradable waste deposited in landfills. CH4 is a greenhouse gas with global warming potential 28 times that of CO2 over a period of 100 years. The produced CH4 in landfills...... is the driving force for advective gas transport, between inside the landfill and the atmosphere, and thus potentially can impact CH4 recovery. The overall goal of this PhD project was to address specific challenges regarding CH4 production and recovery at landfills. The PhD project focused on three topics: 1...

  7. Streaming video-based 3D reconstruction method compatible with existing monoscopic and stereoscopic endoscopy systems

    Science.gov (United States)

    Bouma, Henri; van der Mark, Wannes; Eendebak, Pieter T.; Landsmeer, Sander H.; van Eekeren, Adam W. M.; ter Haar, Frank B.; Wieringa, F. Pieter; van Basten, Jean-Paul

    2012-06-01

    Compared to open surgery, minimal invasive surgery offers reduced trauma and faster recovery. However, lack of direct view limits space perception. Stereo-endoscopy improves depth perception, but is still restricted to the direct endoscopic field-of-view. We describe a novel technology that reconstructs 3D-panoramas from endoscopic video streams providing a much wider cumulative overview. The method is compatible with any endoscope. We demonstrate that it is possible to generate photorealistic 3D-environments from mono- and stereoscopic endoscopy. The resulting 3D-reconstructions can be directly applied in simulators and e-learning. Extended to real-time processing, the method looks promising for telesurgery or other remote vision-guided tasks.

  8. WASS: an open-source stereo processing pipeline for sea waves 3D reconstruction

    Science.gov (United States)

    Bergamasco, Filippo; Benetazzo, Alvise; Torsello, Andrea; Barbariol, Francesco; Carniel, Sandro; Sclavo, Mauro

    2017-04-01

    Stereo 3D reconstruction of ocean waves is gaining more and more popularity in the oceanographic community. In fact, recent advances of both computer vision algorithms and CPU processing power can now allow the study of the spatio-temporal wave fields with unprecedented accuracy, especially at small scales. Even if simple in theory, multiple details are difficult to be mastered for a practitioner so that the implementation of a 3D reconstruction pipeline is in general considered a complex task. For instance, camera calibration, reliable stereo feature matching and mean sea-plane estimation are all factors for which a well designed implementation can make the difference to obtain valuable results. For this reason, we believe that the open availability of a well-tested software package that automates the steps from stereo images to a 3D point cloud would be a valuable addition for future researches in this area. We present WASS, a completely Open-Source stereo processing pipeline for sea waves 3D reconstruction, available at http://www.dais.unive.it/wass/. Our tool completely automates the recovery of dense point clouds from stereo images by providing three main functionalities. First, WASS can automatically recover the extrinsic parameters of the stereo rig (up to scale) so that no delicate calibration has to be performed on the field. Second, WASS implements a fast 3D dense stereo reconstruction procedure so that an accurate 3D point cloud can be computed from each stereo pair. We rely on the well-consolidated OpenCV library both for the image stereo rectification and disparity map recovery. Lastly, a set of 2D and 3D filtering techniques both on the disparity map and the produced point cloud are implemented to remove the vast majority of erroneous points that can naturally arise while analyzing the optically complex nature of the water surface (examples are sun-glares, large white-capped areas, fog and water areosol, etc). Developed to be as fast as possible, WASS

  9. Acute, but not chronic, exposure to d-cycloserine facilitates extinction and modulates spontaneous recovery of a conditioned taste aversion.

    Science.gov (United States)

    Mickley, G Andrew; Remus, Jennifer L; Ramos, Linnet; Wilson, Gina N; Biesan, Orion R; Ketchesin, Kyle D

    2012-01-18

    D-cycloserine, the glutamate N-methyl-D-aspartate receptor partial agonist, has been reported to facilitate the extinction of learned fears acquired in both naturalistic and laboratory settings. The current study extended this literature by evaluating the ability of either chronic or acute administrations of DCS to modulate the extinction and spontaneous recovery of a conditioned taste aversion (CTA). Twenty-three hour fluid-deprived Sprague-Dawley rats acquired a strong CTA following 3 pairings of a conditioned stimulus (CS; 0.3% oral saccharin)+unconditioned stimulus [US; 81 mg/kg (i.p.) lithium chloride (LiCl)]. In separate groups of rats, we then employed 2 different extinction paradigms: (1) CS-only (CSO-EXT) in which saccharin was presented every-other day, or (2) Explicitly Unpaired (EU-EXT) in which both saccharin and LiCl were presented but on alternate days. Previous studies have indicated that the EU-EXT procedure speeds up the extinction process. Further, spontaneous recovery of a CTA emerges following CSO-EXT but the EU-EXT paradigm causes a suppression of spontaneous recovery. DCS (15 mg/kg, i.p.) was administered immediately after daily liquid presentations (saccharin or water, alternate days) during the extinction period. In an acute drug manipulation, DCS (15 mg/kg, i.p.) or saline control injections were administered for 4 days only. This was done during one of 3 different phases of extinction [i.e., static (2-5%), early dynamic (8-16%), or middle dynamic (20-40%) saccharin reacceptance]. Other animals assigned to the chronic DCS condition received daily DCS (15 mg/kg, i.p.) throughout extinction. Changes in saccharin drinking in these animals were compared to the data from rats that received no drug (saline controls). Once rats met our criterion for asymptotic extinction (90% reacceptance of the CS) they entered a 30-day latency period during which they received water for 1 h/day. The day after the completion of the latency period, a final

  10. Magnetic Resonance Imaging in Breath-Hold Divers with Cerebral Decompression Sickness

    Directory of Open Access Journals (Sweden)

    Ryu Matsuo

    2014-01-01

    Full Text Available The mechanism of cerebral decompression sickness (DCS is still unclear. We report 2 cases of breath-hold divers with cerebral DCS in whom magnetic resonance imaging (MRI demonstrated distinctive characteristics. One case presented right hemiparesthesia, diplopia, and gait disturbance after breath-hold diving into the sea at a depth of 20 m. Brain MRI with fluid-attenuated inversion recovery (FLAIR sequence revealed multiple hyperintense lesions in the right frontal lobe, bilateral thalamus, pons, and right cerebellar hemisphere. The second case presented visual and gait disturbance after repetitive breath-hold diving into the sea. FLAIR imaging showed hyperintense areas in the bilateral occipito-parietal lobes. In both cases, diffusion-weighted imaging and apparent diffusion coefficient mapping revealed hyperintense areas in the lesions identified by FLAIR. Moreover, follow-up MRI showed attenuation of the FLAIR signal abnormalities. These findings are suggestive of transient hyperpermeability in the microvasculature as a possible cause of cerebral DCS.

  11. 3D IBFV : Hardware-Accelerated 3D Flow Visualization

    NARCIS (Netherlands)

    Telea, Alexandru; Wijk, Jarke J. van

    2003-01-01

    We present a hardware-accelerated method for visualizing 3D flow fields. The method is based on insertion, advection, and decay of dye. To this aim, we extend the texture-based IBFV technique for 2D flow visualization in two main directions. First, we decompose the 3D flow visualization problem in a

  12. 3D IBFV : hardware-accelerated 3D flow visualization

    NARCIS (Netherlands)

    Telea, A.C.; Wijk, van J.J.

    2003-01-01

    We present a hardware-accelerated method for visualizing 3D flow fields. The method is based on insertion, advection, and decay of dye. To this aim, we extend the texture-based IBFV technique presented by van Wijk (2001) for 2D flow visualization in two main directions. First, we decompose the 3D

  13. Acute D2/D3 dopaminergic agonism but chronic D2/D3 antagonism prevents NMDA antagonist neurotoxicity.

    Science.gov (United States)

    Farber, Nuri B; Nemmers, Brian; Noguchi, Kevin K

    2006-09-15

    Antagonists of the N-methyl-D-aspartate (NMDA) glutamate receptor, most likely by producing disinhibtion in complex circuits, acutely produce psychosis and cognitive disturbances in humans, and neurotoxicity in rodents. Studies examining NMDA Receptor Hypofunction (NRHypo) neurotoxicity in animals, therefore, may provide insights into the pathophysiology of psychotic disorders. Dopaminergic D2 and/or D3 agents can modify psychosis over days to weeks, suggesting involvement of these transmitter system(s). We studied the ability of D2/D3 agonists and antagonists to modify NRHypo neurotoxicity both after a one-time acute exposure and after chronic daily exposure. Here we report that D2/D3 dopamine agonists, probably via D3 receptors, prevent NRHypo neurotoxicity when given acutely. The protective effect with D2/D3 agonists is not seen after chronic daily dosing. In contrast, the antipsychotic haloperidol does not affect NRHypo neurotoxicity when given acutely at D2/D3 doses. However, after chronic daily dosing of 1, 3, or 5 weeks, haloperidol does prevent NRHypo neurotoxicity with longer durations producing greater protection. Understanding the changes that occur in the NRHypo circuit after chronic exposure to dopaminergic agents could provide important clues into the pathophysiology of psychotic disorders.

  14. Importance of contrast-enhanced fluid-attenuated inversion reconvery magnetic resonance imaging in various intracranial pathologic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Kyoung; Lee, Eun Ja; Kim, Sung Won; Lee, Yong Seok [Dept. of Radiology, Dongguk University Ilsan Hospital, Goyang(Korea, Republic of)

    2016-02-15

    Intracranial lesions may show contrast enhancement through various mechanisms that are closely associated with the disease process. The preferred magnetic resonance sequence in contrast imaging is T1-weighted imaging (T1WI) at most institutions. However, lesion enhancement is occasionally inconspicuous on T1WI. Although fluid-attenuated inversion recovery (FLAIR) sequences are commonly considered as T2-weighted imaging with dark cerebrospinal fluid, they also show mild T1-weighted contrast, which is responsible for the contrast enhancement. For several years, FLAIR imaging has been successfully incorporated as a routine sequence at our institution for contrast-enhanced (CE) brain imaging in detecting various intracranial diseases. In this pictorial essay, we describe and illustrate the diagnostic importance of CE-FLAIR imaging in various intracranial pathologic conditions.

  15. T1- Thresholds in Black Holes Increase Clinical-Radiological Correlation in Multiple Sclerosis Patients.

    Science.gov (United States)

    Thaler, Christian; Faizy, Tobias; Sedlacik, Jan; Holst, Brigitte; Stellmann, Jan-Patrick; Young, Kim Lea; Heesen, Christoph; Fiehler, Jens; Siemonsen, Susanne

    2015-01-01

    Magnetic Resonance Imaging (MRI) is an established tool in diagnosing and evaluating disease activity in Multiple Sclerosis (MS). While clinical-radiological correlations are limited in general, hypointense T1 lesions (also known as Black Holes (BH)) have shown some promising results. The definition of BHs is very heterogeneous and depends on subjective visual evaluation. We aimed to improve clinical-radiological correlations by defining BHs using T1 relaxation time (T1-RT) thresholds to achieve best possible correlation between BH lesion volume and clinical disability. 40 patients with mainly relapsing-remitting MS underwent MRI including 3-dimensional fluid attenuated inversion recovery (FLAIR), magnetization-prepared rapid gradient echo (MPRAGE) before and after Gadolinium (GD) injection and double inversion-contrast magnetization-prepared rapid gradient echo (MP2RAGE) sequences. BHs (BHvis) were marked by two raters on native T1-weighted (T1w)-MPRAGE, contrast-enhancing lesions (CE lesions) on T1w-MPRAGE after GD and FLAIR lesions (total-FLAIR lesions) were detected separately. BHvis and total-FLAIR lesion maps were registered to MP2RAGE images, and the mean T1-RT were calculated for all lesion ROIs. Mean T1 values of the cortex (CTX) were calculated for each patient. Subsequently, Spearman rank correlations between clinical scores (Expanded Disability Status Scale and Multiple Sclerosis Functional Composite) and lesion volume were determined for different T1-RT thresholds. Significant differences in T1-RT were obtained between all different lesion types with highest T1 values in visually marked BHs (BHvis: 1453.3±213.4 ms, total-FLAIR lesions: 1394.33±187.38 ms, CTX: 1305.6±35.8 ms; p1500 ms (Expanded Disability Status Scale vs. lesion volume: rBHvis = 0.442 and rtotal-FLAIR = 0.497, p<0.05; Multiple Sclerosis Functional Composite vs. lesion volume: rBHvis = -0.53 and rtotal-FLAIR = -0.627, p<0.05). Clinical-radiological correlations in MS patients are

  16. Characterizing 3D sensors using the 3D modulation transfer function

    Science.gov (United States)

    Kellner, Timo; Breitbarth, Andreas; Zhang, Chen; Notni, Gunther

    2018-03-01

    The fields of optical 3D measurement system applications are continuously expanding and becoming more and more diverse. To evaluate appropriate systems for various measurement tasks, comparable parameters are necessary, whereas the 3D modulation transfer function (3D-MTF) has been established as a further criterion. Its aim is the determination of the system response between the measurement of a straight, sharp-edged cube and its opposite ideal calculated one. Within the scope of this work simulations and practical investigations regarding the 3D-MTF’s influences and its main issues are specifically investigated. Therefore, different determined edge radii representing the high-frequency spectra lead to various decreasing 3D-MTF characteristics. Furthermore, rising sampling frequencies improve its maximum transfer value to a saturation point in dependence of the radius. To approve these results of previous simulations, three fringe projection scanners were selected to determine the diversity. As the best 3D-MTF characteristic, a saturated transfer value of H_3D( f_N, 3D) = 0.79 has been identified at a sufficient sampling frequency, which is reached at four times the Nyquist limit. This high 3D resolution can mainly be achieved due to an improved camera projector interaction. Additionally, too small sampling ratios lead to uncertainties in the edge function determination, while higher ratios do not show major improvements. In conclusion, the 3D-MTF algorithm has thus been practically verified and its repeatability as well as its robustness have been confirmed.

  17. Naked-eye 3D imaging employing a modified MIMO micro-ring conjugate mirrors

    Science.gov (United States)

    Youplao, P.; Pornsuwancharoen, N.; Amiri, I. S.; Thieu, V. N.; Yupapin, P.

    2018-03-01

    In this work, the use of a micro-conjugate mirror that can produce the 3D image incident probe and display is proposed. By using the proposed system together with the concept of naked-eye 3D imaging, a pixel and a large volume pixel of a 3D image can be created and displayed as naked-eye perception, which is valuable for the large volume naked-eye 3D imaging applications. In operation, a naked-eye 3D image that has a large pixel volume will be constructed by using the MIMO micro-ring conjugate mirror system. Thereafter, these 3D images, formed by the first micro-ring conjugate mirror system, can be transmitted through an optical link to a short distance away and reconstructed via the recovery conjugate mirror at the other end of the transmission. The image transmission is performed by the Fourier integral in MATLAB and compares to the Opti-wave program results. The Fourier convolution is also included for the large volume image transmission. The simulation is used for the manipulation, where the array of a micro-conjugate mirror system is designed and simulated for the MIMO system. The naked-eye 3D imaging is confirmed by the concept of the conjugate mirror in both the input and output images, in terms of the four-wave mixing (FWM), which is discussed and interpreted.

  18. Aspects of defects in 3d-3d correspondence

    International Nuclear Information System (INIS)

    Gang, Dongmin; Kim, Nakwoo; Romo, Mauricio; Yamazaki, Masahito

    2016-01-01

    In this paper we study supersymmetric co-dimension 2 and 4 defects in the compactification of the 6d (2,0) theory of type A_N_−_1 on a 3-manifold M. The so-called 3d-3d correspondence is a relation between complexified Chern-Simons theory (with gauge group SL(N,ℂ)) on M and a 3d N=2 theory T_N[M]. We study this correspondence in the presence of supersymmetric defects, which are knots/links inside the 3-manifold. Our study employs a number of different methods: state-integral models for complex Chern-Simons theory, cluster algebra techniques, domain wall theory T[SU(N)], 5d N=2 SYM, and also supergravity analysis through holography. These methods are complementary and we find agreement between them. In some cases the results lead to highly non-trivial predictions on the partition function. Our discussion includes a general expression for the cluster partition function, which can be used to compute in the presence of maximal and certain class of non-maximal punctures when N>2. We also highlight the non-Abelian description of the 3d N=2T_N[M] theory with defect included, when such a description is available. This paper is a companion to our shorter paper http://dx.doi.org/10.1088/1751-8113/49/30/30LT02, which summarizes our main results.

  19. Studies on the analysis of 25-hydroxyvitamin D{sub 3} by isotope-dilution liquid chromatography–tandem mass spectrometry using enzyme-assisted derivatisation

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Khalik, Jonas, E-mail: J.A.F.A.ABDEL-KHALIK.744116@swansea.ac.uk [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Crick, Peter J. [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Carter, Graham D. [DEQAS, Imperial College Healthcare NHS Trust, Clinical Biochemistry Department, Charing Cross Hospital, Fulham Palace Rd, London W6 8RF (United Kingdom); Makin, Hugh L. [Barts and the Royal London School of Medicine and Dentistry, Queen Mary University of London, London E1 2AD (United Kingdom); Wang, Yuqin [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Griffiths, William J., E-mail: w.j.griffiths@swansea.ac.uk [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom)

    2014-04-11

    Highlights: • New method for the analysis of 25-hydroxyvitamin D{sub 3} exploiting Girard P derivatisation. • Method also applicable to vitamin D{sub 3}, 1α,25- and 24,25-dihydroxyvitamin D{sub 3}. • By modification of the method 3-epi-25-hydroxyvitamin D{sub 3} can also be analysed. - Abstract: The total serum concentration of 25-hydroxyvitamins D (25-hydroxyvitamin D{sub 3} and 25-hydroxyvitamin D{sub 2}) is currently used as an indicator of vitamins D status. Vitamins D insufficiency is claimed to be associated with multiple diseases, thus accurate and precise reference methods for the quantification of 25-hydroxyvitamins D are needed. Here we present a novel enzyme-assisted derivatisation method for the analysis of vitamins D metabolites in adult serum utilising 25-[26,26,26,27,27,27-{sup 2}H{sub 6}]hydroxyvitamin D{sub 3} as the internal standard. Extraction of 25-hydroxyvitamins D from serum is performed with acetonitrile, which is shown to be more efficient than ethanol. Cholesterol oxidase is used to oxidize the 3β-hydroxy group in the vitamins D metabolites followed by derivatisation of the newly formed 3-oxo group with Girard P reagent. 17β-Hydroxysteroid dehydrogenase type 10 is shown to oxidize selectively the 3α-hydroxy group in the 3α-hydroxy epimer of 25-hydroxyvitamin D{sub 3}. Quantification is achieved by isotope-dilution liquid chromatography–tandem mass spectrometry. Recovery experiments for 25-hydroxyvitamin D{sub 3} performed on adult human serum give recovery of 102–106%. Furthermore in addition to 25-hydroxyvitamin D{sub 3}, 24,25-dihydroxyvitamin D{sub 3} and other uncharacterised dihydroxy metabolites, were detected in adult human serum.

  20. Visualization of endolymphatic hydrops in meniere's disease after single-dose intravenous gadolinium-based contrast medium. Timing of optimal enhancement

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Yamazaki, Masahiro; Kawai, Hisashi; Bokura, Kiminori; Sone, Michihiko; Nakashima, Tsutomu

    2012-01-01

    Visualization of endolymphatic hydrops (EH) in patients with Meniere's disease (MD) is now possible by heavily T 2 -weighted 3-dimensional fluid-attenuated inversion recovery (h T 2 W-3D-FLAIR) obtained 4 hours after intravenous (IV) administration of single dose gadolinium-based contrast medium (GBCM). Although maximum enhancement has been reported 4 hours after contrast administration in healthy volunteers, the timing of optimal enhancement in patients with MD is not reported. We investigated if that optimal timing is earlier or later than 4 hours. We evaluated 10 consecutive patients with suspected MD whom we randomly divided into 2 groups. We obtained h T 2 W-3D-FLAIR before GBCM administration and 10 min, 3.5 hours, and 4 hours after GBCM administration in Group A and before and 10 min, 4 hours, and 4.5 hours after GBCM administration in Group B. We compared signal intensity ratio (SIR) values of the perilymph and pons between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B and evaluated grades of EH at 3.5 and 4 hours in Group A and at 4 and 4.5 hours in Group B. SIR values did not differ significantly between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B. However, SIR values at 4 hours were significantly higher in Group A than Group B. Grades of EH agreed between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B. The optimal timing of contrast enhancement in patients with suspected MD remains unclear, but evaluation of EH may be possible from 3.5 to 4.5 hours after contrast administration. (author)

  1. Experimental acute intracerebral hemorrhage: Value of MR sequences for a safe diagnosis at 1.5 and 0.5 T

    International Nuclear Information System (INIS)

    Kueker, W.; Thron, A.; Thiex, R.; Rohde, I.; Rohde, V.

    2000-01-01

    To determine the detectability of intracerebral hematomas with MR imaging at 1.5 T and 0.5 T with fluid attenuated inversion recovery turbo spin-echo (FLAIR) and gradient-echo sequences. Material and Methods: Twenty-seven intracerebral hematomas were created in 25 piglets by injection of venous blood into the brain through a burr hole. All were imaged with T2*-weighted gradient echo sequences (fast field echo, FFE), T2-weighted fluid attenuated inversion recovery turbo spin-echo sequences (FLAIR), T2-weighted turbo spin-echo (TSE) and T1-weighted spin-echo sequences. Follow-up was performed on the 2nd, 4th and 10th postoperative days. Ten animals were additionally investigated with similar sequences at 0.5 T. Histologic correlation was obtained in all cases. Results: T2* FFE sequences detected all acute intracerebral hematomas and demonstrated the size correctly at 1.5 T and 0.5 T. The conspicuity was better at 1.5 T. FLAIR sequences were unreliable in the hyperacute phase at 1.5 T. However, subarachnoid and intraventricular extension was best appreciated with FLAIR images. T2 TSE images were incapable of detecting para ventricular and subarachnoid hemorrhages, but clearly demonstrated intracerebral blood in other locations. T1-weighted images were insensitive to hemorrhage in the acute state but very useful in subacute and chronic hematomas. Conclusion: The safe and reliable diagnosis of intracerebral hemorrhage is probably possible with MR imaging at 1.5 T and 0.5 T even of hematomas less than 90 min old, but requires the application of at least FLAIR, T2* FFE and T1 sequences and is therefore time consuming

  2. D3-??????????????????????? ? ???? ?????????? ?2 ?????? ?????? ?????

    OpenAIRE

    ?????????, ????; ???????, ???????; ??????, ?????????; ?????????????, ????; ??????, ??????

    2011-01-01

    ????? ?????? ??????? ????? ????? ??????????? ?????? ?????? ????? ? ?????? ? ???????? ????? ?????????. ?????????? ???????????? ?????? ?? ?2 ?????? ?????? ????? ??????? ?? D3 ???????????????? ??????? ??????????? ?????? ????????? ????? ?????????? ??? ??? ??????????. ? ????? ????????????? ??????????? ??? ????????? ????????????? ?????????? ???? ?????????? ?????????? ????? ????????? ?????? ???????? ?? D3-????????????????? ???????.

  3. Photoaffinity labeling of serum vitamin D binding protein by 3-deoxy-3-azido-25-hydroxyvitamin D3

    International Nuclear Information System (INIS)

    Link, R.P.; Kutner, A.; Schnoes, H.K.; DeLuca, H.F.

    1987-01-01

    3-Deoxy-3-azido-25-hydroxyvitamin D3 was covalently incorporated in the 25-hydroxyvitamin D3 binding site of purified human plasma vitamin D binding protein. Competition experiments showed that 3-deoxy-3-azido-25-hydroxyvitamin D3 and 25-hydroxyvitamin D3 bind at the same site on the protein. Tritiated 3-deoxy-3-azido-25-hydroxyvitamin D3 was synthesized from tritiated 25-hydroxyvitamin D3, retaining the high specific activity of the parent compound. The tritiated azido label bound reversibly to human vitamin D binding protein in the dark and covalently to human vitamin D binding protein after exposure to ultraviolet light. Reversible binding of tritiated 3-deoxy-3-azido-25-hydroxyvitamin D3 was compared to tritiated 25-hydroxyvitamin D3 binding to human vitamin D binding protein. Scatchard analysis of the data indicated equivalent maximum density binding sites with a KD,app of 0.21 nM for 25-hydroxyvitamin D3 and a KD,app of 1.3 nM for the azido derivative. Covalent binding was observed only after exposure to ultraviolet irradiation, with an average of 3% of the reversibly bound label becoming covalently bound to vitamin D binding protein. The covalent binding was reduced 70-80% when 25-hydroxyvitamin D3 was present, indicating strong covalent binding at the vitamin D binding site of the protein. When tritiated 3-deoxy-3-azido-25-hydroxyvitamin D3 was incubated with human plasma in the absence and presence of 25-hydroxyvitamin D3, 12% of the azido derivative was reversibly bound to vitamin D binding protein. After ultraviolet irradiation, four plasma proteins covalently bound the azido label, but vitamin D binding protein was the only protein of the four that was unlabeled in the presence of 25-hydroxyvitamin D3

  4. 3D for free using the Mac's standard apps : converting raw 3D text files to QuickDraw 3D's 3DMF format using AppleScript

    NARCIS (Netherlands)

    Djajadiningrat, J.P.

    2003-01-01

    This article introduces you to the basics of 3D files in general and the 3D Metafile (3DMF), QuickDraw 3D's native 3D format, in particular. It shows how you can use AppleScript to easily convert a raw 3D text file into a 3DMF readable by the QuickDraw 3D Viewer or any other QuickDraw 3D compatible

  5. Classifying magnetic resonance image modalities with convolutional neural networks

    Science.gov (United States)

    Remedios, Samuel; Pham, Dzung L.; Butman, John A.; Roy, Snehashis

    2018-02-01

    Magnetic Resonance (MR) imaging allows the acquisition of images with different contrast properties depending on the acquisition protocol and the magnetic properties of tissues. Many MR brain image processing techniques, such as tissue segmentation, require multiple MR contrasts as inputs, and each contrast is treated differently. Thus it is advantageous to automate the identification of image contrasts for various purposes, such as facilitating image processing pipelines, and managing and maintaining large databases via content-based image retrieval (CBIR). Most automated CBIR techniques focus on a two-step process: extracting features from data and classifying the image based on these features. We present a novel 3D deep convolutional neural network (CNN)- based method for MR image contrast classification. The proposed CNN automatically identifies the MR contrast of an input brain image volume. Specifically, we explored three classification problems: (1) identify T1-weighted (T1-w), T2-weighted (T2-w), and fluid-attenuated inversion recovery (FLAIR) contrasts, (2) identify pre vs postcontrast T1, (3) identify pre vs post-contrast FLAIR. A total of 3418 image volumes acquired from multiple sites and multiple scanners were used. To evaluate each task, the proposed model was trained on 2137 images and tested on the remaining 1281 images. Results showed that image volumes were correctly classified with 97.57% accuracy.

  6. 3D Elevation Program—Virtual USA in 3D

    Science.gov (United States)

    Lukas, Vicki; Stoker, J.M.

    2016-04-14

    The U.S. Geological Survey (USGS) 3D Elevation Program (3DEP) uses a laser system called ‘lidar’ (light detection and ranging) to create a virtual reality map of the Nation that is very accurate. 3D maps have many uses with new uses being discovered all the time.  

  7. New approach for measuring 3D space by using Advanced SURF Algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Youm, Minkyo; Min, Byungil; Suh, Kyungsuk [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Backgeun [Sungkyunkwan Univ., Suwon (Korea, Republic of)

    2013-05-15

    The nuclear disasters compared to natural disaster create a more extreme condition for analyzing and evaluating. In this paper, measuring 3D space and modeling was studied by simple pictures in case of small sand dune. The suggested method can be used for the acquisition of spatial information by robot at the disaster area. As a result, these data are helpful for identify the damaged part, degree of damage and determination of recovery sequences. In this study we are improving computer vision algorithm for 3-D geo spatial information measurement. And confirm by test. First, we can get noticeable improvement of 3-D geo spatial information result by SURF algorithm and photogrammetry surveying. Second, we can confirm not only decrease algorithm running time, but also increase matching points through epi polar line filtering. From the study, we are extracting 3-D model by open source algorithm and delete miss match point by filtering method. However on characteristic of SURF algorithm, it can't find match point if structure don't have strong feature. So we will need more study about find feature point if structure don't have strong feature.

  8. Comparison of MR sequences in early cerebral infarction at 0.5 T

    International Nuclear Information System (INIS)

    Saatci, I.; Baskan, O.; Cekirge, H.S.; Besim, A.

    2000-01-01

    To compare the diagnostic values of fluid-attenuated inversion recovery (FLAIR) and gradient spin-echo (GRASE) with those of conventional spin-echo (SE) and fast SE T2-weighted sequences in the evaluation of acute cerebrovascular lesions at 0.5 T. Material and Methods: Twenty-two consecutive patients with the clinical diagnosis of acute cerebrovascular accident were examined by MR imaging within the first 48 h of ictus. MR examination included 5-mm axial conventional SE and turbo SE (TSE) T2-weighted, dual-echo GRASE and FLAIR sequences. The patients also had pre- and postcontrast T1-weighted axial images. Two examiners evaluated the images and scored the conspicuity of the acute lesions. Results: Regardless of location, FLAIR provided the best lesion conspicuity in the detection of acute infarcts, followed by the GRASE sequence. In the posterior fossa, TSE and SE demonstrated the lesions better than GRASE and FLAIR techniques. In the detection of hemorrhagic elements within the ischemic region, TSE demonstrated statistically significant superiority over other sequences. Conclusion: In the detection of acute ischemic lesions in locations other than the posterior fossa, FLAIR provided the best lesion conspicuity among four T2-weighted sequences, including SE, TSE, GRASE and FLAIR. However, for the posterior fossa examination, preference of SE or TSE T2-weighted sequences is suggested

  9. Comparison of MR sequences in early cerebral infarction at 0.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Saatci, I.; Baskan, O.; Cekirge, H.S.; Besim, A. [Hacettepe Univ. Hospital, Ankara (Turkey). Radiology Dept.

    2000-11-01

    To compare the diagnostic values of fluid-attenuated inversion recovery (FLAIR) and gradient spin-echo (GRASE) with those of conventional spin-echo (SE) and fast SE T2-weighted sequences in the evaluation of acute cerebrovascular lesions at 0.5 T. Material and Methods: Twenty-two consecutive patients with the clinical diagnosis of acute cerebrovascular accident were examined by MR imaging within the first 48 h of ictus. MR examination included 5-mm axial conventional SE and turbo SE (TSE) T2-weighted, dual-echo GRASE and FLAIR sequences. The patients also had pre- and postcontrast T1-weighted axial images. Two examiners evaluated the images and scored the conspicuity of the acute lesions. Results: Regardless of location, FLAIR provided the best lesion conspicuity in the detection of acute infarcts, followed by the GRASE sequence. In the posterior fossa, TSE and SE demonstrated the lesions better than GRASE and FLAIR techniques. In the detection of hemorrhagic elements within the ischemic region, TSE demonstrated statistically significant superiority over other sequences. Conclusion: In the detection of acute ischemic lesions in locations other than the posterior fossa, FLAIR provided the best lesion conspicuity among four T2-weighted sequences, including SE, TSE, GRASE and FLAIR. However, for the posterior fossa examination, preference of SE or TSE T2-weighted sequences is suggested.

  10. 3D Animation Essentials

    CERN Document Server

    Beane, Andy

    2012-01-01

    The essential fundamentals of 3D animation for aspiring 3D artists 3D is everywhere--video games, movie and television special effects, mobile devices, etc. Many aspiring artists and animators have grown up with 3D and computers, and naturally gravitate to this field as their area of interest. Bringing a blend of studio and classroom experience to offer you thorough coverage of the 3D animation industry, this must-have book shows you what it takes to create compelling and realistic 3D imagery. Serves as the first step to understanding the language of 3D and computer graphics (CG)Covers 3D anim

  11. 3DSEM: A 3D microscopy dataset

    Directory of Open Access Journals (Sweden)

    Ahmad P. Tafti

    2016-03-01

    Full Text Available The Scanning Electron Microscope (SEM as a 2D imaging instrument has been widely used in many scientific disciplines including biological, mechanical, and materials sciences to determine the surface attributes of microscopic objects. However the SEM micrographs still remain 2D images. To effectively measure and visualize the surface properties, we need to truly restore the 3D shape model from 2D SEM images. Having 3D surfaces would provide anatomic shape of micro-samples which allows for quantitative measurements and informative visualization of the specimens being investigated. The 3DSEM is a dataset for 3D microscopy vision which is freely available at [1] for any academic, educational, and research purposes. The dataset includes both 2D images and 3D reconstructed surfaces of several real microscopic samples. Keywords: 3D microscopy dataset, 3D microscopy vision, 3D SEM surface reconstruction, Scanning Electron Microscope (SEM

  12. Two-Way 4D Printing: A Review on the Reversibility of 3D-Printed Shape Memory Materials

    Directory of Open Access Journals (Sweden)

    Amelia Yilin Lee

    2017-10-01

    Full Text Available The rapid development of additive manufacturing and advances in shape memory materials have fueled the progress of four-dimensional (4D printing. With the right external stimulus, the need for human interaction, sensors, and batteries will be eliminated, and by using additive manufacturing, more complex devices and parts can be produced. With the current understanding of shape memory mechanisms and with improved design for additive manufacturing, reversibility in 4D printing has recently been proven to be feasible. Conventional one-way 4D printing requires human interaction in the programming (or shape-setting phase, but reversible 4D printing, or two-way 4D printing, will fully eliminate the need for human interference, as the programming stage is replaced with another stimulus. This allows reversible 4D printed parts to be fully dependent on external stimuli; parts can also be potentially reused after every recovery, or even used in continuous cycles—an aspect that carries industrial appeal. This paper presents a review on the mechanisms of shape memory materials that have led to 4D printing, current findings regarding 4D printing in alloys and polymers, and their respective limitations. The reversibility of shape memory materials and their feasibility to be fabricated using three-dimensional (3D printing are summarized and critically analyzed. For reversible 4D printing, the methods of 3D printing, mechanisms used for actuation, and strategies to achieve reversibility are also highlighted. Finally, prospective future research directions in reversible 4D printing are suggested.

  13. Phase correction for three-dimensional (3D) diffusion-weighted interleaved EPI using 3D multiplexed sensitivity encoding and reconstruction (3D-MUSER).

    Science.gov (United States)

    Chang, Hing-Chiu; Hui, Edward S; Chiu, Pui-Wai; Liu, Xiaoxi; Chen, Nan-Kuei

    2018-05-01

    Three-dimensional (3D) multiplexed sensitivity encoding and reconstruction (3D-MUSER) algorithm is proposed to reduce aliasing artifacts and signal corruption caused by inter-shot 3D phase variations in 3D diffusion-weighted echo planar imaging (DW-EPI). 3D-MUSER extends the original framework of multiplexed sensitivity encoding (MUSE) to a hybrid k-space-based reconstruction, thereby enabling the correction of inter-shot 3D phase variations. A 3D single-shot EPI navigator echo was used to measure inter-shot 3D phase variations. The performance of 3D-MUSER was evaluated by analyses of point-spread function (PSF), signal-to-noise ratio (SNR), and artifact levels. The efficacy of phase correction using 3D-MUSER for different slab thicknesses and b-values were investigated. Simulations showed that 3D-MUSER could eliminate artifacts because of through-slab phase variation and reduce noise amplification because of SENSE reconstruction. All aliasing artifacts and signal corruption in 3D interleaved DW-EPI acquired with different slab thicknesses and b-values were reduced by our new algorithm. A near-whole brain single-slab 3D DTI with 1.3-mm isotropic voxel acquired at 1.5T was successfully demonstrated. 3D phase correction for 3D interleaved DW-EPI data is made possible by 3D-MUSER, thereby improving feasible slab thickness and maximum feasible b-value. Magn Reson Med 79:2702-2712, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  14. EUROPEANA AND 3D

    Directory of Open Access Journals (Sweden)

    D. Pletinckx

    2012-09-01

    Full Text Available The current 3D hype creates a lot of interest in 3D. People go to 3D movies, but are we ready to use 3D in our homes, in our offices, in our communication? Are we ready to deliver real 3D to a general public and use interactive 3D in a meaningful way to enjoy, learn, communicate? The CARARE project is realising this for the moment in the domain of monuments and archaeology, so that real 3D of archaeological sites and European monuments will be available to the general public by 2012. There are several aspects to this endeavour. First of all is the technical aspect of flawlessly delivering 3D content over all platforms and operating systems, without installing software. We have currently a working solution in PDF, but HTML5 will probably be the future. Secondly, there is still little knowledge on how to create 3D learning objects, 3D tourist information or 3D scholarly communication. We are still in a prototype phase when it comes to integrate 3D objects in physical or virtual museums. Nevertheless, Europeana has a tremendous potential as a multi-facetted virtual museum. Finally, 3D has a large potential to act as a hub of information, linking to related 2D imagery, texts, video, sound. We describe how to create such rich, explorable 3D objects that can be used intuitively by the generic Europeana user and what metadata is needed to support the semantic linking.

  15. MRI findings in eastern equine encephalitis: the "parenthesis" sign.

    Science.gov (United States)

    Nickerson, Joshua P; Kannabiran, Suma; Burbank, Heather N

    2016-01-01

    Two patients with eastern equine encephalitis (EEE) presented to a tertiary referral center. Both subjects' brain magnetic resonance imaging showed T2/FLAIR (fluid-attenuated inversion recovery) hyperintensities including linear areas of hyperintensity in the external and internal capsules with sparing of the lentiform nuclei. Single case reports of imaging findings in EEE exist with nonspecific patterns of abnormality. We propose that this "( ) parentheses sign" on T2 or FLAIR imaging may distinguish EEE from other processes. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Relationship between Contrast Enhancement of the Perivascular Space in the Basal Ganglia and Endolymphatic Volume Ratio.

    Science.gov (United States)

    Ohashi, Toshio; Naganawa, Shinji; Katagiri, Toshio; Kuno, Kayao

    2018-01-10

    We routinely obtain the endolymphatic hydrops (EH) image using heavily T 2 -weighted three dimensional-fluid attenuated inversion recovery (hT 2 w-3D-FLAIR) imaging at 4 hours after intravenous administration of a single-dose of gadolinium-based contrast media (IV-SD-GBCM). While repeating the examination, we speculated that the contrast enhancement of the perivascular space (PVS) in the basal ganglia might be related to the degree of EH. Therefore, the purpose of this study was to investigate the relationship between the endolymphatic volume ratio (%EL volume ) and the signal intensity of the PVS (SI-PVS). In 20 patients with a suspicion of EH, a heavily T 2 -weighted 3D-turbo spin echo sequence for MR cisternography (MRC) and an hT 2 w-3D-FLAIR as a positive perilymph image (PPI) were obtained at 4 hours after IV-SD-GBCM. The %EL volume of the cochlea and the vestibule were measured on the previously reported HYDROPS2-Mi2 image. The PVS in the basal ganglia was segmented on MRC using a region-growing method. The PVS regions were copied and pasted onto the PPI, and the SI-PVS was measured. The larger value of the right and the left ears was employed as the %EL volume , and the weighted average of both sides was employed as the SI-PVS. The correlation between the %EL volume and the SI-PVS was evaluated. There was a strong negative linear correlation between the %EL volume of the cochlea and the SI-PVS (r = -0.743, P < 0.001); however, there was no significant correlation between the %EL volume of the vestibule and the SI-PVS (r = -0.267, P = 0.256). There was a strong negative correlation between the cochlear %EL volume and the SI-PVS. Contrast enhancement of PVS might be a biomarker of EH.

  17. Long T2 suppression in native lung 3-D imaging using k-space reordered inversion recovery dual-echo ultrashort echo time MRI.

    Science.gov (United States)

    Gai, Neville D; Malayeri, Ashkan A; Bluemke, David A

    2017-08-01

    Long T2 species can interfere with visualization of short T2 tissue imaging. For example, visualization of lung parenchyma can be hindered by breathing artifacts primarily from fat in the chest wall. The purpose of this work was to design and evaluate a scheme for long T2 species suppression in lung parenchyma imaging using 3-D inversion recovery double-echo ultrashort echo time imaging with a k-space reordering scheme for artifact suppression. A hyperbolic secant (HS) pulse was evaluated for different tissues (T1/T2). Bloch simulations were performed with the inversion pulse followed by segmented UTE acquisition. Point spread function (PSF) was simulated for a standard interleaved acquisition order and a modulo 2 forward-reverse acquisition order. Phantom and in vivo images (eight volunteers) were acquired with both acquisition orders. Contrast to noise ratio (CNR) was evaluated in in vivo images prior to and after introduction of the long T2 suppression scheme. The PSF as well as phantom and in vivo images demonstrated reduction in artifacts arising from k-space modulation after using the reordering scheme. CNR measured between lung and fat and lung and muscle increased from -114 and -148.5 to +12.5 and 2.8 after use of the IR-DUTE sequence. Paired t test between the CNRs obtained from UTE and IR-DUTE showed significant positive change (p lung-fat CNR and p = 0.03 for lung-muscle CNR). Full 3-D lung parenchyma imaging with improved positive contrast between lung and other long T2 tissue types can be achieved robustly in a clinically feasible time using IR-DUTE with image subtraction when segmented radial acquisition with k-space reordering is employed.

  18. Rational design of 3D inverse opal heterogeneous composite microspheres as excellent visible-light-induced NO2 sensors at room temperature.

    Science.gov (United States)

    Wang, Tianshuang; Yu, Qi; Zhang, Sufang; Kou, Xueying; Sun, Peng; Lu, Geyu

    2018-03-08

    The lower gas sensitivity, humidity dependence of the gas sensing properties, and long recovery times of room-temperature gas sensors severely limit their applications. Herein, to address these issues, a series of 3D inverse opal (IO) In 2 O 3 -ZnO heterogeneous composite microspheres (HCMs) are fabricated by ultrasonic spray pyrolysis (USP) employing self-assembled sulfonated polystyrene (S-PS) spheres as a sacrificial template. The 3D IO In 2 O 3 -ZnO HCMs possess highly ordered 3D inverse opal structures and bimodal (meso-scale and macro-scale) pores, which can provide large accessible surface areas and rapid mass transfer, resulting in enhanced gas sensing characteristics. Furthermore, the 3D IO architecture and n-n heterojunctions can extend the photoabsorption range to the visible light area, effectively prolonging the lifetimes of photo-generated charge carriers, and can increase separation of visible light-generated charges. As a result, the as-prepared 3D IO In 2 O 3 -ZnO HCMs deliver excellent NO 2 sensing performance under visible light irradiation at room temperature, such as high sensitivity (R gas /R air = 54.3 to 5 ppm NO 2 ), low detection limit (250 ppb), fast recovery time (188 s), excellent selectivity and humidity independence. These enhanced photo-electronic gas sensing properties are attributed to the combination of highly ordered 3D IO microspheres and In 2 O 3 -ZnO heterogeneous composites.

  19. From 3D view to 3D print

    Science.gov (United States)

    Dima, M.; Farisato, G.; Bergomi, M.; Viotto, V.; Magrin, D.; Greggio, D.; Farinato, J.; Marafatto, L.; Ragazzoni, R.; Piazza, D.

    2014-08-01

    In the last few years 3D printing is getting more and more popular and used in many fields going from manufacturing to industrial design, architecture, medical support and aerospace. 3D printing is an evolution of bi-dimensional printing, which allows to obtain a solid object from a 3D model, realized with a 3D modelling software. The final product is obtained using an additive process, in which successive layers of material are laid down one over the other. A 3D printer allows to realize, in a simple way, very complex shapes, which would be quite difficult to be produced with dedicated conventional facilities. Thanks to the fact that the 3D printing is obtained superposing one layer to the others, it doesn't need any particular work flow and it is sufficient to simply draw the model and send it to print. Many different kinds of 3D printers exist based on the technology and material used for layer deposition. A common material used by the toner is ABS plastics, which is a light and rigid thermoplastic polymer, whose peculiar mechanical properties make it diffusely used in several fields, like pipes production and cars interiors manufacturing. I used this technology to create a 1:1 scale model of the telescope which is the hardware core of the space small mission CHEOPS (CHaracterising ExOPlanets Satellite) by ESA, which aims to characterize EXOplanets via transits observations. The telescope has a Ritchey-Chrétien configuration with a 30cm aperture and the launch is foreseen in 2017. In this paper, I present the different phases for the realization of such a model, focusing onto pros and cons of this kind of technology. For example, because of the finite printable volume (10×10×12 inches in the x, y and z directions respectively), it has been necessary to split the largest parts of the instrument in smaller components to be then reassembled and post-processed. A further issue is the resolution of the printed material, which is expressed in terms of layers

  20. Vitamin D3 and 25-hydroxyvitamin D3 in pork and their relationship to vitamin D status in pigs

    DEFF Research Database (Denmark)

    Burild, Anders; Lauridsen, Charlotte; Faqir, Nasrin

    2016-01-01

    The content of vitamin D in pork produced in conventional systems depends on the vitamin D concentration in the pig feed. Both vitamin D3 and 25-hydroxyvitamin D3 (25(OH)D3) are essential sources of dietary vitamin D; however, bioavailability assessed by serum 25(OH)D3 concentration is reported...... of vitamin D3 and 25(OH)D3 in the pig feed for 49 d before slaughter. Concurrently, the 25(OH)D3 level in serum was investigated as a biomarker to assess the content of vitamin D3 and 25(OH)D3 in pig tissues. Adipose tissue, white and red muscle, the liver and serum were sampled from pigs fed feed containing...... either vitamin D3 or 25(OH)D3 at 5, 20, 35 or 50 µg/kg feed for 7 weeks before slaughter. The tissue 25(OH)D3 level was significantly higher in the pigs fed 25(OH)D3 compared with those fed vitamin D3, while the tissue vitamin D3 level was higher in the pigs fed vitamin D3 compared with those fed 25(OH...

  1. A 2D driven 3D vessel segmentation algorithm for 3D digital subtraction angiography data

    International Nuclear Information System (INIS)

    Spiegel, M; Hornegger, J; Redel, T; Struffert, T; Doerfler, A

    2011-01-01

    Cerebrovascular disease is among the leading causes of death in western industrial nations. 3D rotational angiography delivers indispensable information on vessel morphology and pathology. Physicians make use of this to analyze vessel geometry in detail, i.e. vessel diameters, location and size of aneurysms, to come up with a clinical decision. 3D segmentation is a crucial step in this pipeline. Although a lot of different methods are available nowadays, all of them lack a method to validate the results for the individual patient. Therefore, we propose a novel 2D digital subtraction angiography (DSA)-driven 3D vessel segmentation and validation framework. 2D DSA projections are clinically considered as gold standard when it comes to measurements of vessel diameter or the neck size of aneurysms. An ellipsoid vessel model is applied to deliver the initial 3D segmentation. To assess the accuracy of the 3D vessel segmentation, its forward projections are iteratively overlaid with the corresponding 2D DSA projections. Local vessel discrepancies are modeled by a global 2D/3D optimization function to adjust the 3D vessel segmentation toward the 2D vessel contours. Our framework has been evaluated on phantom data as well as on ten patient datasets. Three 2D DSA projections from varying viewing angles have been used for each dataset. The novel 2D driven 3D vessel segmentation approach shows superior results against state-of-the-art segmentations like region growing, i.e. an improvement of 7.2% points in precision and 5.8% points for the Dice coefficient. This method opens up future clinical applications requiring the greatest vessel accuracy, e.g. computational fluid dynamic modeling.

  2. 3D gaze tracking system for NVidia 3D Vision®.

    Science.gov (United States)

    Wibirama, Sunu; Hamamoto, Kazuhiko

    2013-01-01

    Inappropriate parallax setting in stereoscopic content generally causes visual fatigue and visual discomfort. To optimize three dimensional (3D) effects in stereoscopic content by taking into account health issue, understanding how user gazes at 3D direction in virtual space is currently an important research topic. In this paper, we report the study of developing a novel 3D gaze tracking system for Nvidia 3D Vision(®) to be used in desktop stereoscopic display. We suggest an optimized geometric method to accurately measure the position of virtual 3D object. Our experimental result shows that the proposed system achieved better accuracy compared to conventional geometric method by average errors 0.83 cm, 0.87 cm, and 1.06 cm in X, Y, and Z dimensions, respectively.

  3. MRI assessment of relapsed glioblastoma during treatment with bevacizumab: Volumetric measurement of enhanced and FLAIR lesions for evaluation of response and progression—A pilot study

    International Nuclear Information System (INIS)

    Pichler, Josef; Pachinger, Corinna; Pelz, Manuela; Kleiser, Raimund

    2013-01-01

    Purpose: To develop a magnetic resonance imaging (MRI) metric that is useful for therapy monitoring in patients with relapsed glioblastoma (GBM) during treatment with the antiangiogenic monoclonal antibody bevacizumab (Bev). We evaluated the feasibility of tumour volume measurement with our software tool in clinical routine and tried to establish reproducible and quantitative parameters for surveillance of patients on treatment with antiangiogenic drugs. Materials and methods: In this retrospective institutional pilot study, 18 patients (11 men, 7 women; mean age 53.5) with recurrent GBM received bevacizumab and irinotecan every two weeks as second line therapy. Follow up scans were assessed every two to four months. Data were collected on a 1.5 T MR System (Siemens, Symphony) with the standard head coil using our standardized tumour protocol. Volumetric measurement was performed with a commercial available software stroketool in FLAIR and T1-c imaging with following procedure: Pre-processing involved cutting noise and electing a Gaussian of 3 × 3 to smooth images, selecting a ROI (region of interest) in healthy brain area of the contra lateral side with quantifying the intensity value, adding 20% to this value to define the threshold level. Only values above this threshold are left corresponding to the tumour lesion. For the volumetric measurement the detected tumour area was circuited in all slices and finally summing up all values and multiplied by slice thickness to get the whole volume. Results: With McDonalds criteria progression was indicated in 14 out of 18 patients. In contrast, volumetric measurement showed an increase of contrast enhancement of >25%, defined as threshold for progression, in 11 patients (78%) and in 12 patients (85%) in FLAIR volume, respectively. 6 patients revealed that volumes in MRI increased earlier than the last scan, which was primarily defined as the date of progression with McDonald criteria, changing PFS after re-evaluation of

  4. MRI assessment of relapsed glioblastoma during treatment with bevacizumab: volumetric measurement of enhanced and FLAIR lesions for evaluation of response and progression--a pilot study.

    Science.gov (United States)

    Pichler, Josef; Pachinger, Corinna; Pelz, Manuela; Kleiser, Raimund

    2013-05-01

    To develop a magnetic resonance imaging (MRI) metric that is useful for therapy monitoring in patients with relapsed glioblastoma (GBM) during treatment with the antiangiogenic monoclonal antibody bevacizumab (Bev). We evaluated the feasibility of tumour volume measurement with our software tool in clinical routine and tried to establish reproducible and quantitative parameters for surveillance of patients on treatment with antiangiogenic drugs. In this retrospective institutional pilot study, 18 patients (11 men, 7 women; mean age 53.5) with recurrent GBM received bevacizumab and irinotecan every two weeks as second line therapy. Follow up scans were assessed every two to four months. Data were collected on a 1.5 T MR System (Siemens, Symphony) with the standard head coil using our standardized tumour protocol. Volumetric measurement was performed with a commercial available software stroketool in FLAIR and T1-c imaging with following procedure: Pre-processing involved cutting noise and electing a Gaussian of 3 × 3 to smooth images, selecting a ROI (region of interest) in healthy brain area of the contra lateral side with quantifying the intensity value, adding 20% to this value to define the threshold level. Only values above this threshold are left corresponding to the tumour lesion. For the volumetric measurement the detected tumour area was circuited in all slices and finally summing up all values and multiplied by slice thickness to get the whole volume. With McDonalds criteria progression was indicated in 14 out of 18 patients. In contrast, volumetric measurement showed an increase of contrast enhancement of >25%, defined as threshold for progression, in 11 patients (78%) and in 12 patients (85%) in FLAIR volume, respectively. 6 patients revealed that volumes in MRI increased earlier than the last scan, which was primarily defined as the date of progression with McDonald criteria, changing PFS after re-evaluation of the tumour volumes from 6.8 to 5.6 months

  5. MRI assessment of relapsed glioblastoma during treatment with bevacizumab: Volumetric measurement of enhanced and FLAIR lesions for evaluation of response and progression—A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Pichler, Josef, E-mail: josef.pichler@gespag.at [Wagner Jauregg Weg 15, 4020 Linz, Landesnervenklinik Linz (Austria); Pachinger, Corinna, E-mail: pachingercorinna@gmx.at [Wagner Jauregg Weg 15, 4020 Linz, Landesnervenklinik Linz (Austria); Pelz, Manuela, E-mail: mauela.pelz@gespag.at [Wagner Jauregg Weg 15, 4020 Linz, Landesnervenklinik Linz (Austria); Kleiser, Raimund, E-mail: raimund.kleiser@gespag.at [Wagner Jauregg Weg 15, 4020 Linz, Landesnervenklinik Linz (Austria)

    2013-05-15

    Purpose: To develop a magnetic resonance imaging (MRI) metric that is useful for therapy monitoring in patients with relapsed glioblastoma (GBM) during treatment with the antiangiogenic monoclonal antibody bevacizumab (Bev). We evaluated the feasibility of tumour volume measurement with our software tool in clinical routine and tried to establish reproducible and quantitative parameters for surveillance of patients on treatment with antiangiogenic drugs. Materials and methods: In this retrospective institutional pilot study, 18 patients (11 men, 7 women; mean age 53.5) with recurrent GBM received bevacizumab and irinotecan every two weeks as second line therapy. Follow up scans were assessed every two to four months. Data were collected on a 1.5 T MR System (Siemens, Symphony) with the standard head coil using our standardized tumour protocol. Volumetric measurement was performed with a commercial available software stroketool in FLAIR and T1-c imaging with following procedure: Pre-processing involved cutting noise and electing a Gaussian of 3 × 3 to smooth images, selecting a ROI (region of interest) in healthy brain area of the contra lateral side with quantifying the intensity value, adding 20% to this value to define the threshold level. Only values above this threshold are left corresponding to the tumour lesion. For the volumetric measurement the detected tumour area was circuited in all slices and finally summing up all values and multiplied by slice thickness to get the whole volume. Results: With McDonalds criteria progression was indicated in 14 out of 18 patients. In contrast, volumetric measurement showed an increase of contrast enhancement of >25%, defined as threshold for progression, in 11 patients (78%) and in 12 patients (85%) in FLAIR volume, respectively. 6 patients revealed that volumes in MRI increased earlier than the last scan, which was primarily defined as the date of progression with McDonald criteria, changing PFS after re-evaluation of

  6. Recovery coefficients as a test of system linearity of response in PET

    International Nuclear Information System (INIS)

    Geworski, L.; Munz, D.L.; Knoop, B.; Hofmann, M.; Knapp, W.H.

    2002-01-01

    Aim: New imaging protocols have created an increasing demand for quantitation in dedicated PET. Besides attenuation and scatter correction the recovery correction, accounting for the instrument's limited spatial resolution, has gained importance. For clinical practicability these corrections should work independent from the object, i.e. from the actual distribution of emitter and absorber. Aim of the study was to test this object independency, i.e. system linearity of response, by comparing recovery coefficients (RC) determined for different object geometries. In fact, this comparison may serve as a final test on system linearity of response, as measured on the quantitative accuracy by which the activity concentration in small lesions can be recovered. Method: For hot and cold spot imaging situations spatial distribution of activity is different. Therefore, scatter correction algorithm has to deal with different scatter distributions. If all factors disturbing system linearity, specifically scatter and attenuation, are corrected to a sufficient degree of accuracy, the system behaves linearly resulting in the theoretical relationship. CSRC = (1-HSRC). Thus, this equation, applied hot and cold spot measurements, will serve as a test on the effectiveness of the corrections and, hence, as a test of system linearity of response. Following IEC standard procedures (IEC 61675-1) measurements were done with and without interplane septa (2D/3D) on an ECAT EXACT 922 using a cylindrical phantom containing six spheres of different diameters (10 mm - 40 mm). All data were corrected for attenuation (transmission scan) and scatter (2D: deconvolution, 3D: scatter model), as implemented in the scanner's standard software. Recovery coefficients were determined for cold (CSRC) and hot (HSRC) lesions using both 2D and 3D acquisition mode. Results: CSRC directly measured versus CSRC calculated according to eq. (1) from HSRC resulted in an excellent agreement for both 2D and 3D data

  7. LandSIM3D: modellazione in real time 3D di dati geografici

    Directory of Open Access Journals (Sweden)

    Lambo Srl Lambo Srl

    2009-03-01

    Full Text Available LandSIM3D: realtime 3D modelling of geographic data LandSIM3D allows to model in 3D an existing landscape in a few hours only and geo-referenced offering great landscape analysis and understanding tools. 3D projects can then be inserted into the existing landscape with ease and precision. The project alternatives and impact can then be visualized and studied into their immediate environmental. The complex evolution of the landscape in the future can also be simulated and the landscape model can be manipulated interactively and better shared with colleagues. For that reason, LandSIM3D is different from traditional 3D imagery solutions, normally reserved for computer graphics experts. For more information about LandSIM3D, go to www.landsim3d.com.

  8. INTEGRATION OF VIDEO IMAGES AND CAD WIREFRAMES FOR 3D OBJECT LOCALIZATION

    Directory of Open Access Journals (Sweden)

    R. A. Persad

    2012-07-01

    Full Text Available The tracking of moving objects from single images has received widespread attention in photogrammetric computer vision and considered to be at a state of maturity. This paper presents a model-driven solution for localizing moving objects detected from monocular, rotating and zooming video images in a 3D reference frame. To realize such a system, the recovery of 2D to 3D projection parameters is essential. Automatic estimation of these parameters is critical, particularly for pan-tilt-zoom (PTZ surveillance cameras where parameters change spontaneously upon camera motion. In this work, an algorithm for automated parameter retrieval is proposed. This is achieved by matching linear features between incoming images from video sequences and simple geometric 3D CAD wireframe models of man-made structures. The feature matching schema uses a hypothesis-verify optimization framework referred to as LR-RANSAC. This novel method improves the computational efficiency of the matching process in comparison to the standard RANSAC robust estimator. To demonstrate the applicability and performance of the method, experiments have been performed on indoor and outdoor image sequences under varying conditions with lighting changes and occlusions. Reliability of the matching algorithm has been analyzed by comparing the automatically determined camera parameters with ground truth (GT. Dependability of the retrieved parameters for 3D localization has also been assessed by comparing the difference between 3D positions of moving image objects estimated using the LR-RANSAC-derived parameters and those computed using GT parameters.

  9. Identification of the transition arrays 3d74s-3d74p in Br X and 3d64s-3d64p in Br XI

    International Nuclear Information System (INIS)

    Zeng, X.T.; Jupen, C.; Bengtsson, P.; Engstroem, L.; Westerlind, M.; Martinson, I.

    1991-01-01

    We report a beam-foil study of multiply ionized bromine in the region 400-1300A, performed with 6 and 8 MeV Br ions from a tandem accelerator. At these energies transitions belonging to Fe-like Br X and Mn-like Br XI are expected to be prominent. We have identified 31 lines as 3d 7 4s-3d 7 4p transitions in Br X, from which 16 levels of the previously unknown 3d 7 4s configuration could be established. We have also added 6 new 3d 7 4p levels to the 99 previously known. For Br XI we have classified 9 lines as 3d 6 4s-3d 6 4p combinations. The line identifications have been corroborated by isoelectronic comparisons and theoretical calculations using the superposition-of-configurations technique. (orig.)

  10. Investigation of the C-3-epi-25(OH)D3 of 25-hydroxyvitamin D3 in urban schoolchildren.

    Science.gov (United States)

    Berger, Samantha E; Van Rompay, Maria I; Gordon, Catherine M; Goodman, Elizabeth; Eliasziw, Misha; Holick, Michael F; Sacheck, Jennifer M

    2018-03-01

    The physiological relevance C-3 epimer of 25-hydroxyvitamin D (3-epi-25(OH)D) is not well understood among youth. The objective of this study was to assess whether demographic/physiologic characteristics were associated with 3-epi-25(OH)D 3 concentrations in youth. Associations between 3-epi-25(OH)D 3 and demographics and between 3-epi-25(OH)D 3 , total 25-hydroxyvitamin (25(OH)D) (25(OH)D 2 + 25(OH)D 3 ), total cholesterol, high-density lipoprotein, low-density lipoprotein, and triglycerides were examined in racially/ethnically diverse schoolchildren (n = 682; age, 8-15 years) at Boston-area urban schools. Approximately 50% of participants had detectable 3-epi-25(OH)D 3 (range 0.95-3.95 ng/mL). The percentage of 3-epi-25(OH)D 3 of total 25(OH)D ranged from 2.5% to 17.0% (median 5.5%). Males were 38% more likely than females to have detectable 3-epi-25(OH)D 3 concentrations. Both Asian and black race/ethnicity were associated with lower odds of having detectable 3-epi-25(OH)D 3 compared with non-Hispanic white children (Asian vs. white, odds ratio (OR) 0.28, 95% confidence interval (CI) 0.14-0.53; black vs. white, OR 0.38, 95%CI 0.23-0.63, p 30 ng/mL) 25(OH)D concentration was associated with higher odds of having detectable 3-epi-25(OH)D 3 than having an inadequate (<20 ng/mL) concentration (OR 4.78, 95%CI 3.23-6.94 or OR 14.10, 95%CI 7.10-28.0, respectively). There was no association between 3-epi-25(OH)D 3 and blood lipids. However, when considering 3-epi-25(OH)D 3 as a percentage of total 25(OH)D, total cholesterol was lower in children with percent 3-epi-25(OH)D 3 above the median (mean difference -7.1 mg/dL, p = 0.01). In conclusion, among schoolchildren, sex, race/ethnicity, and total serum 25(OH)D concentration is differentially associated with 3-epi-25(OH)D. The physiological relevance of 3-epi-25(OH)D 3 may be related to the 3-epi-25(OH)D 3 as a percentage of total 25(OH)D and should be considered in future investigations.

  11. "3D fusion" echocardiography improves 3D left ventricular assessment: comparison with 2D contrast echocardiography.

    Science.gov (United States)

    Augustine, Daniel; Yaqub, Mohammad; Szmigielski, Cezary; Lima, Eduardo; Petersen, Steffen E; Becher, Harald; Noble, J Alison; Leeson, Paul

    2015-02-01

    Three-dimensional fusion echocardiography (3DFE) is a novel postprocessing approach that utilizes imaging data acquired from multiple 3D acquisitions. We assessed image quality, endocardial border definition, and cardiac wall motion in patients using 3DFE compared to standard 3D images (3D) and results obtained with contrast echocardiography (2DC). Twenty-four patients (mean age 66.9 ± 13 years, 17 males, 7 females) undergoing 2DC had three, noncontrast, 3D apical volumes acquired at rest. Images were fused using an automated image fusion approach. Quality of the 3DFE was compared to both 3D and 2DC based on contrast-to-noise ratio (CNR) and endocardial border definition. We then compared clinical wall-motion score index (WMSI) calculated from 3DFE and 3D to those obtained from 2DC images. Fused 3D volumes had significantly improved CNR (8.92 ± 1.35 vs. 6.59 ± 1.19, P echocardiography (1.06 ± 0.09 vs. 1.07 ± 0.15, P = 0.69), whereas unfused images produced significantly more variable results (1.19 ± 0.30). This was confirmed by a better intraclass correlation coefficient (ICC 0.72; 95% CI 0.32-0.88) relative to comparisons with unfused images (ICC 0.56; 95% CI 0.02-0.81). 3DFE significantly improves left ventricular image quality compared to unfused 3D in a patient population and allows noncontrast assessment of wall motion that approaches that achieved with 2D contrast echocardiography. © 2014, Wiley Periodicals, Inc.

  12. iCAVE: an open source tool for visualizing biomolecular networks in 3D, stereoscopic 3D and immersive 3D.

    Science.gov (United States)

    Liluashvili, Vaja; Kalayci, Selim; Fluder, Eugene; Wilson, Manda; Gabow, Aaron; Gümüs, Zeynep H

    2017-08-01

    Visualizations of biomolecular networks assist in systems-level data exploration in many cellular processes. Data generated from high-throughput experiments increasingly inform these networks, yet current tools do not adequately scale with concomitant increase in their size and complexity. We present an open source software platform, interactome-CAVE (iCAVE), for visualizing large and complex biomolecular interaction networks in 3D. Users can explore networks (i) in 3D using a desktop, (ii) in stereoscopic 3D using 3D-vision glasses and a desktop, or (iii) in immersive 3D within a CAVE environment. iCAVE introduces 3D extensions of known 2D network layout, clustering, and edge-bundling algorithms, as well as new 3D network layout algorithms. Furthermore, users can simultaneously query several built-in databases within iCAVE for network generation or visualize their own networks (e.g., disease, drug, protein, metabolite). iCAVE has modular structure that allows rapid development by addition of algorithms, datasets, or features without affecting other parts of the code. Overall, iCAVE is the first freely available open source tool that enables 3D (optionally stereoscopic or immersive) visualizations of complex, dense, or multi-layered biomolecular networks. While primarily designed for researchers utilizing biomolecular networks, iCAVE can assist researchers in any field. © The Authors 2017. Published by Oxford University Press.

  13. 3D accelerator magnet calculations using MAGNUS-3D

    International Nuclear Information System (INIS)

    Pissanetzky, S.; Miao, Y.

    1989-01-01

    The steady trend towards increased magnetic and geometric complexity in the design of accelerator magnets has caused a need for reliable 3D computer models and a better understanding of the behavior of magnetic system in three dimensions. The capabilities of the MAGNUS-3D family of programs are ideally suited to solve this class of problems and provide insight into 3D effects. MAGNUS-3D can solve any problem of magnetostatics involving permanent magnets, nonlinear ferromagnetic materials and electric conductors. MAGNUS-3D uses the finite element method and the two-scalar-potentials formulation of Maxwell's equations to obtain the solution, which can then be used interactively to obtain tables of field components at specific points or lines, plots of field lines, function graphs representing a field component plotted against a coordinate along any line in space (such as the beam line), and views of the conductors, the mesh and the magnetic bodies. The magnetic quantities that can be calculated include the force or torque on conductors or magnetic parts, the energy, the flux through a specified surface, line integrals of any field component along any line in space, and the average field or potential harmonic coefficients. We describe the programs with emphasis placed on their use for accelerator magnet design, and present an advanced example of actual calculations. (orig.)

  14. 40 CFR 35.928-3 - Implementation of the industrial cost recovery system.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Implementation of the industrial cost...-Clean Water Act § 35.928-3 Implementation of the industrial cost recovery system. (a) When a grantee's industrial cost recovery system is approved, implementation of the approved system shall become a condition...

  15. Recording stereoscopic 3D neurosurgery with a head-mounted 3D camera system.

    Science.gov (United States)

    Lee, Brian; Chen, Brian R; Chen, Beverly B; Lu, James Y; Giannotta, Steven L

    2015-06-01

    Stereoscopic three-dimensional (3D) imaging can present more information to the viewer and further enhance the learning experience over traditional two-dimensional (2D) video. Most 3D surgical videos are recorded from the operating microscope and only feature the crux, or the most important part of the surgery, leaving out other crucial parts of surgery including the opening, approach, and closing of the surgical site. In addition, many other surgeries including complex spine, trauma, and intensive care unit procedures are also rarely recorded. We describe and share our experience with a commercially available head-mounted stereoscopic 3D camera system to obtain stereoscopic 3D recordings of these seldom recorded aspects of neurosurgery. The strengths and limitations of using the GoPro(®) 3D system as a head-mounted stereoscopic 3D camera system in the operating room are reviewed in detail. Over the past several years, we have recorded in stereoscopic 3D over 50 cranial and spinal surgeries and created a library for education purposes. We have found the head-mounted stereoscopic 3D camera system to be a valuable asset to supplement 3D footage from a 3D microscope. We expect that these comprehensive 3D surgical videos will become an important facet of resident education and ultimately lead to improved patient care.

  16. L'uso del doppiaggio e del sottotitolaggio nell'insegnamento della L2: Il caso della piattaforma ClipFlair

    Directory of Open Access Journals (Sweden)

    Lupe Romero

    2016-01-01

    Full Text Available Abstract – The purpose of this paper is to present the Clipflair project, a web platform for foreign language learning (FLL through revoicing and captioning of clips. Using audiovisual material in the language classroom is a common resource for teachers since it introduces variety, provides exposure to nonverbal cultural elements and, most importantly, presents linguistic and cultural aspects of communication in their context. However, teachers using this resource face the difficulty of finding active tasks that will engage learners and discourage passive viewing. ClipFlair proposes working with AV material productively while also motivating learners by getting them to revoice or caption a clip. Revoicing is a term used to refer to (rerecording voice onto a clip, as in dubbing, free commentary, audio description and karaoke singing. The term captioning refers to adding written text to a clip, such as standard subtitles, annotations and intertitles. Clips can be short video or audio files, including documentaries, film scenes, news pieces, animations and songs. ClipFlair develops materials that enable foreign language learners to practice all four standard CEFR skills: writing, speaking, listening and reading. Within the project’s scope, more than 350 ready-made activities, which involve captioning and/or revoicing of clips, has been created. These activities has been created for more than 16 languages including English, Spanish and Italian, but focus is placed on less widely taught languages, namely Estonian, Greek, Romanian and Polish, as well as minority languages, i.e. Basque, Catalan and Irish. Non-European languages, namely Arabic, Chinese, Japanese, Russian and Ukrainian are also included. The platform has three different areas: The Gallery offers the materials and the activities; the Studio area, offers a captioning and revoicing tools, in order to create or practice and learn languages by using the activities; the Social Network area

  17. Neuroradiological study of cerebral microlesions (2). Changes in elderly

    International Nuclear Information System (INIS)

    Qu, Hong; Nishimaru, Katsuya; Utsunomiya, Hidetsuna; Une, Hiroshi

    2003-01-01

    Some of the cerebral microlesions less than 3 mm in diameter observed on magnetic resonance imaging (MRI) are considered to represent pathological processes. The present study investigated changes due to aging in microlesions according to anatomical regions and phenotypes. A total of 390 cases without localized lesions other than lacune less than 15 mm in diameter were studied. Microlesion type on MRI was categorized into hypo-, iso-, and hyper-intensities on T1-weighted (T1WI), T2-weighted (T2WI), and proton-weighted or fluid-attenuated inversion recovery (proton/FLAIR) images. Correlations between unidentified bright objects (UBO) in white matter and vascular risk factors were analyzed using logistic regression analysis. Microlesions of the upper basal ganglia showing low intensity on T1WI, high intensity on T2WI and iso intensity on proton/FLAIR, and showing low intensity on T1WI, high intensity on T2WI and low intensity on proton/FLAIR increased with age, whereas those showing low intensity on T1WI, iso intensity on T2WI, and low intensity on proton/FLAIR of the upper basal ganglia decreased. In subcortical white matter, microlesions of the first two types: and those showing iso intensity on T1WI, high intensity on T2WI and iso intensity on proton/FLAIR decreased with age. Conversely, UBO increased with age, and significantly correlated with hypertension. Although microlesions in the upper basal ganglia increase with age, those in the subcortical white matter decrease with age. These observations suggest pathological changes surrounding small arteries with aging in the brain. (author)

  18. 2D-Driven 3D Object Detection in RGB-D Images

    KAUST Repository

    Lahoud, Jean

    2017-12-25

    In this paper, we present a technique that places 3D bounding boxes around objects in an RGB-D scene. Our approach makes best use of the 2D information to quickly reduce the search space in 3D, benefiting from state-of-the-art 2D object detection techniques. We then use the 3D information to orient, place, and score bounding boxes around objects. We independently estimate the orientation for every object, using previous techniques that utilize normal information. Object locations and sizes in 3D are learned using a multilayer perceptron (MLP). In the final step, we refine our detections based on object class relations within a scene. When compared to state-of-the-art detection methods that operate almost entirely in the sparse 3D domain, extensive experiments on the well-known SUN RGB-D dataset [29] show that our proposed method is much faster (4.1s per image) in detecting 3D objects in RGB-D images and performs better (3 mAP higher) than the state-of-the-art method that is 4.7 times slower and comparably to the method that is two orders of magnitude slower. This work hints at the idea that 2D-driven object detection in 3D should be further explored, especially in cases where the 3D input is sparse.

  19. E3D, 3-D Elastic Seismic Wave Propagation Code

    International Nuclear Information System (INIS)

    Larsen, S.; Harris, D.; Schultz, C.; Maddix, D.; Bakowsky, T.; Bent, L.

    2004-01-01

    1 - Description of program or function: E3D is capable of simulating seismic wave propagation in a 3D heterogeneous earth. Seismic waves are initiated by earthquake, explosive, and/or other sources. These waves propagate through a 3D geologic model, and are simulated as synthetic seismograms or other graphical output. 2 - Methods: The software simulates wave propagation by solving the elasto-dynamic formulation of the full wave equation on a staggered grid. The solution scheme is 4-order accurate in space, 2-order accurate in time

  20. Dietary Supplements for Health, Adaptation, and Recovery in Athletes.

    Science.gov (United States)

    Rawson, Eric S; Miles, Mary P; Larson-Meyer, D Enette

    2018-03-01

    Some dietary supplements are recommended to athletes based on data that supports improved exercise performance. Other dietary supplements are not ergogenic per se, but may improve health, adaptation to exercise, or recovery from injury, and so could help athletes to train and/or compete more effectively. In this review, we describe several dietary supplements that may improve health, exercise adaptation, or recovery. Creatine monohydrate may improve recovery from and adaptation to intense training, recovery from periods of injury with extreme inactivity, cognitive processing, and reduce severity of or enhance recovery from mild traumatic brain injury (mTBI). Omega 3-fatty acid supplementation may also reduce severity of or enhance recovery from mTBI. Replenishment of vitamin D insufficiency or deficiency will likely improve some aspects of immune, bone, and muscle health. Probiotic supplementation can reduce the incidence, duration, and severity of upper respiratory tract infection, which may indirectly improve training or competitive performance. Preliminary data show that gelatin and/or collagen may improve connective tissue health. Some anti-inflammatory supplements, such as curcumin or tart cherry juice, may reduce inflammation and possibly delayed onset muscle soreness (DOMS). Beta-hydroxy beta-methylbutyrate (HMB) does not consistently increase strength and/or lean mass or reduce markers of muscle damage, but more research on recovery from injury that includes periods of extreme inactivity is needed. Several dietary supplements, including creatine monohydrate, omega 3-fatty acids, vitamin D, probiotics, gelatin, and curcumin/tart cherry juice could help athletes train and/or compete more effectively.

  1. Innovations in 3D printing: a 3D overview from optics to organs.

    Science.gov (United States)

    Schubert, Carl; van Langeveld, Mark C; Donoso, Larry A

    2014-02-01

    3D printing is a method of manufacturing in which materials, such as plastic or metal, are deposited onto one another in layers to produce a three dimensional object, such as a pair of eye glasses or other 3D objects. This process contrasts with traditional ink-based printers which produce a two dimensional object (ink on paper). To date, 3D printing has primarily been used in engineering to create engineering prototypes. However, recent advances in printing materials have now enabled 3D printers to make objects that are comparable with traditionally manufactured items. In contrast with conventional printers, 3D printing has the potential to enable mass customisation of goods on a large scale and has relevance in medicine including ophthalmology. 3D printing has already been proved viable in several medical applications including the manufacture of eyeglasses, custom prosthetic devices and dental implants. In this review, we discuss the potential for 3D printing to revolutionise manufacturing in the same way as the printing press revolutionised conventional printing. The applications and limitations of 3D printing are discussed; the production process is demonstrated by producing a set of eyeglass frames from 3D blueprints.

  2. The D0 online monitoring and automatic DAQ recovery

    International Nuclear Information System (INIS)

    Haas, A.

    2004-01-01

    The DZERO experiment, located at the Fermi National Accelerator Laboratory, has recently started the Run 2 physics program. The detector upgrade included a new Data Acquisition/Level 3 Trigger system. Part of the design for the DAQ/Trigger system was a new monitoring infrastructure. The monitoring was designed to satisfy real-time requirements with 1-second resolution as well as nonreal-time data. It was also designed to handle a large number of displays without putting undue load on the sources of monitoring information. The resulting protocol is based on XML, is easily extensible, and has spawned a large number of displays, clients, and other applications. It is also one of the few sources of detector performance available outside the Online System's security wall. A tool, based on this system, which provides for auto-recovery of DAQ errors, has been designed. This talk will include a description of the DZERO DAQ/Online monitor server, based on the ACE framework, the protocol, the auto-recovery tool, and several of the unique displays which include an ORACLE-based archiver and numerous GUIs

  3. Comparison of between-training-sessions recovery strategies for world-class BMX pilots.

    Science.gov (United States)

    Marquet, Laurie-Anne; Hausswirth, Christophe; Hays, Arnaud; Vettoretti, Fabrice; Brisswalter, Jeanick

    2015-03-01

    To assess the impact of between-training-sessions recovery strategies (passive [PAS], active [ACT], cold-water immersion [CWI], and ingestion of a recovery drink [NUTR]) on maximal cycling performance, perceptions of delayed-onset muscle soreness (DOMS), and fatigue in world-class BMX riders. Eleven elite BMX athletes, members of the French national team (top country in the 2011 international ranking, 4 medals at the 2012 World Championships, top European country), participated in the study, which involved standardized training periods. Athletes performed 3 maximal-sprint power tests: the first day of the week before the training session and before and after training on the third day of the week (D3). The recovery strategy was randomly assigned to each participant on day 2 immediately after the last training period of the day. Perceptions of DOMS and general fatigue were recorded on D3. After training on D3, the decrease in maximal-sprint power (Pmax) was significantly greater for PAS than with CWI (P=.02) and NUTR (P=.018). Similar results were found with ACT (vs CWI P=.044, and vs NUTR P=.042). Self-reported DOMS and fatigue were significantly greater after PAS than after other strategies. For elite BMX riders, between training days, nutritional and/or CWI recovery strategies appear to be best for reducing muscle fatigue and increasing the capacity to withstand the training schedule.

  4. [Effect of 3D printing technology on pelvic fractures:a Meta-analysis].

    Science.gov (United States)

    Zhang, Yu-Dong; Wu, Ren-Yuan; Xie, Ding-Ding; Zhang, Lei; He, Yi; Zhang, Hong

    2018-05-25

    To evaluate the effect of 3D printing technology applied in the surgical treatment of pelvic fractures through the published literatures by Meta-analysis. The PubMed database, EMCC database, CBM database, CNKI database, VIP database and Wanfang database were searched from the date of database foundation to August 2017 to collect the controlled clinical trials in wich 3D printing technology was applied in preoperative planning of pelvic fracture surgery. The retrieved literatures were screened according to predefined inclusion and exclusion criteria, and quality evaluation were performed. Then, the available data were extracted and analyzed with the RevMan5.3 software. Totally 9 controlled clinical trials including 638 cases were chosen. Among them, 279 cases were assigned to the 3D printing technology group and 359 cases to the conventional group. The Meta-analysis results showed that the operative time[SMD=-2.81, 95%CI(-3.76, -1.85)], intraoperative blood loss[SMD=-3.28, 95%CI(-4.72, -1.85)] and the rate of complication [OR=0.47, 95%CI(0.25, 0.87)] in the 3D printing technology were all lower than those in the conventional group;the excellent and good rate of pelvic fracture reduction[OR=2.09, 95%CI(1.32, 3.30)] and postoperative pelvic functional restoration [OR=1.94, 95%CI(1.15, 3.28) in the 3D printing technology were all superior to those in the conventional group. 3D printing technology applied in the surgical treatment of pelvic fractures has the advantage of shorter operative time, less intraoperative blood loss and lower rate of complication, and can improve the quality of pelvic fracture reduction and the recovery of postoperative pelvic function. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  5. Significant Effects of Oral Phenylbutyrate and Vitamin D3 Adjunctive Therapy in Pulmonary Tuberculosis: A Randomized Controlled Trial.

    Directory of Open Access Journals (Sweden)

    Akhirunnesa Mily

    Full Text Available Development of new tuberculosis (TB drugs and alternative treatment strategies are urgently required to control the global spread of TB. Previous results have shown that vitamin D3 (vitD3 and 4-phenyl butyrate (PBA are potent inducers of the host defense peptide LL-37 that possess anti-mycobacterial effects.To examine if oral adjunctive therapy with 5,000IU vitD3 or 2x500 mg PBA or PBA+vitD3 to standard chemotherapy would lead to enhanced recovery in sputum smear-positive pulmonary TB patients.Adult TB patients (n = 288 were enrolled in a randomized, double-blind, placebo-controlled trial conducted in Bangladesh. Primary endpoints included proportions of patients with a negative sputum culture at week 4 and reduction in clinical symptoms at week 8. Clinical assessments and sputum smear microscopy were performed weekly up to week 4, fortnightly up to week 12 and at week 24; TB culture was performed at week 0, 4 and 8; concentrations of LL-37 in cells, 25-hydroxyvitamin D3 (25(OHD3 in plasma and ex vivo bactericidal function of monocyte-derived macrophages (MDM were determined at week 0, 4, 8, 12 and additionally at week 24 for plasma 25(OHD3.At week 4, 71% (46/65 of the patients in the PBA+vitD3-group (p = 0.001 and 61.3% (38/62 in the vitD3-group (p = 0.032 were culture negative compared to 42.2% (27/64 in the placebo-group. The odds of sputum culture being negative at week 4 was 3.42 times higher in the PBA+vitD3-group (p = 0.001 and 2.2 times higher in vitD3-group (p = 0.032 compared to placebo. The concentration of LL-37 in MDM was significantly higher in the PBA-group compared to placebo at week 12 (p = 0.034. Decline in intracellular Mtb growth in MDM was earlier in the PBA-group compared to placebo (log rank 11.38, p = 0.01.Adjunct therapy with PBA+vitD3 or vitD3 or PBA to standard short-course therapy demonstrated beneficial effects towards clinical recovery and holds potential for host-directed-therapy in the treatment of TB

  6. On Alternative Approaches to 3D Image Perception: Monoscopic 3D Techniques

    Science.gov (United States)

    Blundell, Barry G.

    2015-06-01

    In the eighteenth century, techniques that enabled a strong sense of 3D perception to be experienced without recourse to binocular disparities (arising from the spatial separation of the eyes) underpinned the first significant commercial sales of 3D viewing devices and associated content. However following the advent of stereoscopic techniques in the nineteenth century, 3D image depiction has become inextricably linked to binocular parallax and outside the vision science and arts communities relatively little attention has been directed towards earlier approaches. Here we introduce relevant concepts and terminology and consider a number of techniques and optical devices that enable 3D perception to be experienced on the basis of planar images rendered from a single vantage point. Subsequently we allude to possible mechanisms for non-binocular parallax based 3D perception. Particular attention is given to reviewing areas likely to be thought-provoking to those involved in 3D display development, spatial visualization, HCI, and other related areas of interdisciplinary research.

  7. 3D Modelling and Printing Technology to Produce Patient-Specific 3D Models.

    Science.gov (United States)

    Birbara, Nicolette S; Otton, James M; Pather, Nalini

    2017-11-10

    A comprehensive knowledge of mitral valve (MV) anatomy is crucial in the assessment of MV disease. While the use of three-dimensional (3D) modelling and printing in MV assessment has undergone early clinical evaluation, the precision and usefulness of this technology requires further investigation. This study aimed to assess and validate 3D modelling and printing technology to produce patient-specific 3D MV models. A prototype method for MV 3D modelling and printing was developed from computed tomography (CT) scans of a plastinated human heart. Mitral valve models were printed using four 3D printing methods and validated to assess precision. Cardiac CT and 3D echocardiography imaging data of four MV disease patients was used to produce patient-specific 3D printed models, and 40 cardiac health professionals (CHPs) were surveyed on the perceived value and potential uses of 3D models in a clinical setting. The prototype method demonstrated submillimetre precision for all four 3D printing methods used, and statistical analysis showed a significant difference (p3D printed models, particularly using multiple print materials, were considered useful by CHPs for preoperative planning, as well as other applications such as teaching and training. This study suggests that, with further advances in 3D modelling and printing technology, patient-specific 3D MV models could serve as a useful clinical tool. The findings also highlight the potential of this technology to be applied in a variety of medical areas within both clinical and educational settings. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  8. Simultaneous determination of vitamins A and D3 in dairy products by liquid chromatography-tandem mass spectrometry (LC-MS/MS)

    Science.gov (United States)

    Barakat, I. S. A.; Hammouri, M. K.; Habib, I.

    2015-10-01

    A potential method for simultaneous determination of vitamin A and vitamin D3 (25- hydroxyvitamin D3) in fresh milk samples is addressed. The method is based on combination of high performance liquid chromatography and mass spectrometry during the course of analysis. The method applied for determination of vitamins A and D3 on eighteen (18) different fresh milk samples using liquid chromatography along with tandem -mass spectrometry. The work describes the suitability of the proposed method for the simultaneous determination of both vitamins using LC-MS/MS as a specific and quantitative technique. The vitamins of milk were separated by C18 Thermo gold column(100mm × 4.6mm × 5 μm) with a flow rate of 1ml/min (using an isocratic mobile phase). The method was validated using duplicate analyses, relative recovery experiment, and comparative analysis with control samples. Liquid- liquid extraction was employed as a pre-concentration step with n-hexane - dichloromethane mixture (90%:10%) as an extraction solvent. The molecular ions (m/z) appeared near 286 and 385nm and for the base peaks were appeared near 255 and 355nm for vitamins A and D3. Good correlation coefficients were obtained, 0.9999 for vitamin D3 and 0.9994 for vitamin A. The limit of detection and the limit of quantification were found to be 0.09ng/ml and 0.54ng/ml for vitamin D3 and 0.32ng/ml and 1.8ng/ml and for vitamin A. The proposed method showed excellent recoveries, about 98% for both vitamins A and D3.

  9. Procedure for preparation of 3-fluor-D-alanine, 2-deutero-3-fluor-D-alanine and 2,3,3-trideutero-3-fluor-D-alanine and their salts

    International Nuclear Information System (INIS)

    Kollonitsch, J.; Kahan, F.M.

    1971-01-01

    Procedures for the preparation of 3-fluor-D-alanine, 2-deutero-3-fluor-D-alanine and 2,3,3-trideutero-3-fluor-D-alanine, and salts of these compounds, are described. These new compounds are useful antibacterial substances not only applicable in the disinfection of pharmaceutical, dental and medical equipment, but also in the treatment of diseases caused by bacteria, and may be administered orally. While 3-fluor-L-alanine metabolises rapidly with toxic results, 3-fluor-D-alanine is much more slowly broken down in vivo and is not harmful in normal doses. Further it has been found that deuteration gives new deutero-analogues which are less subject to metabolic breaking down and still retain the antibacterial strength of the original compound. The in vivo activity is thereby increased and maintained. (JIW)

  10. Accurate and reproducible reconstruction of coronary arteries and endothelial shear stress calculation using 3D OCT: comparative study to 3D IVUS and 3D QCA.

    Science.gov (United States)

    Toutouzas, Konstantinos; Chatzizisis, Yiannis S; Riga, Maria; Giannopoulos, Andreas; Antoniadis, Antonios P; Tu, Shengxian; Fujino, Yusuke; Mitsouras, Dimitrios; Doulaverakis, Charalampos; Tsampoulatidis, Ioannis; Koutkias, Vassilis G; Bouki, Konstantina; Li, Yingguang; Chouvarda, Ioanna; Cheimariotis, Grigorios; Maglaveras, Nicos; Kompatsiaris, Ioannis; Nakamura, Sunao; Reiber, Johan H C; Rybicki, Frank; Karvounis, Haralambos; Stefanadis, Christodoulos; Tousoulis, Dimitris; Giannoglou, George D

    2015-06-01

    Geometrically-correct 3D OCT is a new imaging modality with the potential to investigate the association of local hemodynamic microenvironment with OCT-derived high-risk features. We aimed to describe the methodology of 3D OCT and investigate the accuracy, inter- and intra-observer agreement of 3D OCT in reconstructing coronary arteries and calculating ESS, using 3D IVUS and 3D QCA as references. 35 coronary artery segments derived from 30 patients were reconstructed in 3D space using 3D OCT. 3D OCT was validated against 3D IVUS and 3D QCA. The agreement in artery reconstruction among 3D OCT, 3D IVUS and 3D QCA was assessed in 3-mm-long subsegments using lumen morphometry and ESS parameters. The inter- and intra-observer agreement of 3D OCT, 3D IVUS and 3D QCA were assessed in a representative sample of 61 subsegments (n = 5 arteries). The data processing times for each reconstruction methodology were also calculated. There was a very high agreement between 3D OCT vs. 3D IVUS and 3D OCT vs. 3D QCA in terms of total reconstructed artery length and volume, as well as in terms of segmental morphometric and ESS metrics with mean differences close to zero and narrow limits of agreement (Bland-Altman analysis). 3D OCT exhibited excellent inter- and intra-observer agreement. The analysis time with 3D OCT was significantly lower compared to 3D IVUS. Geometrically-correct 3D OCT is a feasible, accurate and reproducible 3D reconstruction technique that can perform reliable ESS calculations in coronary arteries. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. The 3d8-(3d74p + 3p53d9) transitions in Br X: A striking case of configuration interaction

    International Nuclear Information System (INIS)

    Kleef, T.A.M. van; Uylings, P.H.M.; Ryabtsev, A.N.; Podobedova, L.I.; Joshi, Y.N.

    1988-01-01

    The spectrum of nine times ionized bromine (Br X) was photographed in the 90-120 A wavelength region on a variety of grazing incidence spectrographs using an open spark and a triggered spark as light sources. The analysis of the 3d 8 -(3d 7 4p + 3p 5 3d 9 ) transitions has resulted in establishing all 9 levels of the 3d 8 configuration, all 12 levels of the 3p 5 3d 9 configuration and 99 out of 110 levels of the 3d 7 4p configuration. The excitation probability of the 3p inner-shell electron increases with nuclear charge and in Br X is comparable with the excitation probability of the optical electrons resulting in a very strong configuration interaction between the 3p 5 3d 9 and 3d 7 4p configurations. Parametric calculations treating these configurations as one super configuration support the analysis. Two hundred and thirty two lines have been classified in this spectrum. (orig.)

  12. Modelling of 3D fractured geological systems - technique and application

    Science.gov (United States)

    Cacace, M.; Scheck-Wenderoth, M.; Cherubini, Y.; Kaiser, B. O.; Bloecher, G.

    2011-12-01

    topics including CO2 storage in deep saline aquifers, shale gas extraction and geothermal heat recovery. The main advantage is that dipping structures can be integrated into a 3D body representing the porous media and the interaction between the discrete flow paths through and across faults and fractures and within the rock matrix can be correctly simulated. In addition the complete workflow is captured by open-source software.

  13. ROOFN3D: DEEP LEARNING TRAINING DATA FOR 3D BUILDING RECONSTRUCTION

    Directory of Open Access Journals (Sweden)

    A. Wichmann

    2018-05-01

    Full Text Available Machine learning methods have gained in importance through the latest development of artificial intelligence and computer hardware. Particularly approaches based on deep learning have shown that they are able to provide state-of-the-art results for various tasks. However, the direct application of deep learning methods to improve the results of 3D building reconstruction is often not possible due, for example, to the lack of suitable training data. To address this issue, we present RoofN3D which provides a new 3D point cloud training dataset that can be used to train machine learning models for different tasks in the context of 3D building reconstruction. It can be used, among others, to train semantic segmentation networks or to learn the structure of buildings and the geometric model construction. Further details about RoofN3D and the developed data preparation framework, which enables the automatic derivation of training data, are described in this paper. Furthermore, we provide an overview of other available 3D point cloud training data and approaches from current literature in which solutions for the application of deep learning to unstructured and not gridded 3D point cloud data are presented.

  14. Comparative evaluation of HD 2D/3D laparoscopic monitors and benchmarking to a theoretically ideal 3D pseudodisplay: even well-experienced laparoscopists perform better with 3D.

    Science.gov (United States)

    Wilhelm, D; Reiser, S; Kohn, N; Witte, M; Leiner, U; Mühlbach, L; Ruschin, D; Reiner, W; Feussner, H

    2014-08-01

    Though theoretically superior to standard 2D visualization, 3D video systems have not yet achieved a breakthrough in laparoscopy. The latest 3D monitors, including autostereoscopic displays and high-definition (HD) resolution, are designed to overcome the existing limitations. We performed a randomized study on 48 individuals with different experience levels in laparoscopy. Three different 3D displays (glasses-based 3D monitor, autostereoscopic display, and a mirror-based theoretically ideal 3D display) were compared to a 2D HD display by assessing multiple performance and mental workload parameters and rating the subjects during a laparoscopic suturing task. Electromagnetic tracking provided information on the instruments' pathlength, movement velocity, and economy. The usability, the perception of visual discomfort, and the quality of image transmission of each monitor were subjectively rated. Almost all performance parameters were superior with the conventional glasses-based 3D display compared to the 2D display and the autostereoscopic display, but were often significantly exceeded by the mirror-based 3D display. Subjects performed a task faster and with greater precision when visualization was achieved with the 3D and the mirror-based display. Instrument pathlength was shortened by improved depth perception. Workload parameters (NASA TLX) did not show significant differences. Test persons complained of impaired vision while using the autostereoscopic monitor. The 3D and 2D displays were rated user-friendly and applicable in daily work. Experienced and inexperienced laparoscopists profited equally from using a 3D display, with an improvement in task performance about 20%. Novel 3D displays improve laparoscopic interventions as a result of faster performance and higher precision without causing a higher mental workload. Therefore, they have the potential to significantly impact the further development of minimally invasive surgery. However, as shown by the

  15. Minimally invasive vascular imaging using 3D-CTA and 3D-MRA. Update

    International Nuclear Information System (INIS)

    Hayashi, Hiromitsu; Kawamata, Hiroshi; Takagi, Ryo; Amano, Yasuo; Wakabayashi, Hiroyuki; Ichikawa, Kazuo; Kumazaki, Tatsuo

    1998-01-01

    Conventional angiography is considered the standard of reference for diagnostic imaging of vascular diseases with respect to its temporal and spatial resolution. This procedure, however is invasive and repeated studies are difficult, and arterial complications are occasionally associated in catheter-based conventional angiography. Recent advances in diagnostic imaging have facilitated three-dimensional CT angiography (3D-CTA) using the volumetric acquisition capabilities inherent in spiral CT and three-dimensional MR angiography (3D-MRA) using the 3D gradient-echo sequence with a bolus injection of Gd-DTPA. These techniques can provide vascular images exceedingly similar to conventional angiograms within a short acquisition time. 3D-CTA and 3D-MRA are considered to be promising, minimally invasive methods for obtaining images of the vasculature, and alternatives to catheter angiography. This study reviews the current status of 3D-CTA and 3D-MRA, with emphasis on the clinical usefulness of three-dimensional diagnostic imaging for the evaluation of diverse vascular pathologies. (author)

  16. 3dRPC: a web server for 3D RNA-protein structure prediction.

    Science.gov (United States)

    Huang, Yangyu; Li, Haotian; Xiao, Yi

    2018-04-01

    RNA-protein interactions occur in many biological processes. To understand the mechanism of these interactions one needs to know three-dimensional (3D) structures of RNA-protein complexes. 3dRPC is an algorithm for prediction of 3D RNA-protein complex structures and consists of a docking algorithm RPDOCK and a scoring function 3dRPC-Score. RPDOCK is used to sample possible complex conformations of an RNA and a protein by calculating the geometric and electrostatic complementarities and stacking interactions at the RNA-protein interface according to the features of atom packing of the interface. 3dRPC-Score is a knowledge-based potential that uses the conformations of nucleotide-amino-acid pairs as statistical variables and that is used to choose the near-native complex-conformations obtained from the docking method above. Recently, we built a web server for 3dRPC. The users can easily use 3dRPC without installing it locally. RNA and protein structures in PDB (Protein Data Bank) format are the only needed input files. It can also incorporate the information of interface residues or residue-pairs obtained from experiments or theoretical predictions to improve the prediction. The address of 3dRPC web server is http://biophy.hust.edu.cn/3dRPC. yxiao@hust.edu.cn.

  17. Vitamin D3 increases in abdominal subcutaneous fat tissue after supplementation with vitamin D3

    DEFF Research Database (Denmark)

    Didriksen, Allan; Burild, Anders; Jakobsen, Jette

    2015-01-01

    stored in all adipose tissue in the body, the median body store was 6.6 mg vitamin D-3 and 0.12 mg 25(OH)D-3 in those given vitamin D-3. Conclusions: Subcutaneous adipose tissue may store large amounts of vitamin D-3. The clinical importance of this storage needs to be determined.......Objective: The objective was to assess the amount of vitamin D-3 stored in adipose tissue after long-term supplementation with high dose vitamin D-3. Design: A cross-sectional study on 29 subjects with impaired glucose tolerance who had participated in a randomized controlled trial with vitamin D-3...... 20 000 IU (500 mu g) per week vs placebo for 3-5 years. Methods: Abdominal subcutaneous fat tissue was obtained by needle biopsy for the measurements of vitamin D-3 and 25-hydroxyvitamin D-3 (25(OH)D-3). Body fat was measured with dual-energy X-ray absorptiometry, and serum 25(OH)D-3 level...

  18. 3D analysis of semiconductor devices: A combination of 3D imaging and 3D elemental analysis

    Science.gov (United States)

    Fu, Bianzhu; Gribelyuk, Michael A.

    2018-04-01

    3D analysis of semiconductor devices using a combination of scanning transmission electron microscopy (STEM) Z-contrast tomography and energy dispersive spectroscopy (EDS) elemental tomography is presented. 3D STEM Z-contrast tomography is useful in revealing the depth information of the sample. However, it suffers from contrast problems between materials with similar atomic numbers. Examples of EDS elemental tomography are presented using an automated EDS tomography system with batch data processing, which greatly reduces the data collection and processing time. 3D EDS elemental tomography reveals more in-depth information about the defect origin in semiconductor failure analysis. The influence of detector shadowing and X-rays absorption on the EDS tomography's result is also discussed.

  19. Straight sinus thrombosis during neurosurgical operation.

    Science.gov (United States)

    Kawano, Hiroto; Nitta, Naoki; Nozaki, Kazuhiko

    2016-01-01

    Perioperative straight sinus thrombosis is extremely rare. A 59-year-old female was admitted to our department because of incidentally found small anterior cerebral artery (A1) aneurysm with microbleeding. After clipping the cerebral aneurysm, she had delayed emergence from anesthesia, total aphasia, and right hemiparesis. Fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) of the head showed hyperintensity in the bilateral caudate nuclei, putamina, and thalami, and computed tomography of the head showed a hyperdense straight sinus, suggesting straight sinus thrombosis. Her neurologic symptoms improved gradually, and she achieved a full clinical recovery, with radiological evidence of recanalization of the straight sinus at follow-up. The possibility of straight sinus thrombosis should be considered in postoperative patients with unexplained postoperative deficits when MRI demonstrates hyperintensity in the bilateral basal ganglia and thalami on FLAIR signal images.

  20. Vitamin D-3 and 25-hydroxyvitamin D-3 in raw and cooked pork cuts

    DEFF Research Database (Denmark)

    Clausen, Ina; Jakobsen, Jette; Leth, Torben

    2003-01-01

    The contents of vitamin D-3 and its metabolically active metabolite 25-hydroxyvitamin D-3 (25OHD(3)) were examined by HPLC in different parts of four common raw pork cuts (loin boneless, leg inside, thin belly, neck) and in cooked meat (loin boneless). In whole raw pork cuts, varying in fat content......, and that rind, despite its limited fat content, has a high concentration of vitamin D-3 and 25OHD(3). Cooking increased vitamin D-3 and 25OHD(3) calculated per 100 g of tissue in all parts and in the whole cut (in whole cuts in raw and cooked meat, respectively: vitamin D-3: 0.15 (0.08-0.24) mug/100 g and 0...... 25OHD(3) contributes significantly to vitamin D activity. Food databases should include concentrations of both vitamin D and 25OHD(3). (C) 2003 Elsevier Ltd. All rights reserved....

  1. Structure of the Human Dopamine D3 Receptor in Complex with a D2/D3 Selective Antagonist

    Energy Technology Data Exchange (ETDEWEB)

    Chien, Ellen Y.T.; Liu, Wei; Zhao, Qiang; Katritch, Vsevolod; Han, Gye Won; Hanson, Michael A.; Shi, Lei; Newman, Amy Hauck; Javitch, Jonathan A.; Cherezov, Vadim; Stevens, Raymond C. (Cornell); (Scripps); (NIDA); (Columbia); (UCSD); (Receptos)

    2010-11-30

    Dopamine modulates movement, cognition, and emotion through activation of dopamine G protein-coupled receptors in the brain. The crystal structure of the human dopamine D3 receptor (D3R) in complex with the small molecule D2R/D3R-specific antagonist eticlopride reveals important features of the ligand binding pocket and extracellular loops. On the intracellular side of the receptor, a locked conformation of the ionic lock and two distinctly different conformations of intracellular loop 2 are observed. Docking of R-22, a D3R-selective antagonist, reveals an extracellular extension of the eticlopride binding site that comprises a second binding pocket for the aryl amide of R-22, which differs between the highly homologous D2R and D3R. This difference provides direction to the design of D3R-selective agents for treating drug abuse and other neuropsychiatric indications.

  2. Open 3D Projects

    Directory of Open Access Journals (Sweden)

    Felician ALECU

    2010-01-01

    Full Text Available Many professionals and 3D artists consider Blender as being the best open source solution for 3D computer graphics. The main features are related to modeling, rendering, shading, imaging, compositing, animation, physics and particles and realtime 3D/game creation.

  3. Modification of 3D milling machine to 3D printer

    OpenAIRE

    Taska, Abraham

    2014-01-01

    Tato práce se zabývá přestavbou gravírovací frézky na 3D tiskárnu. V první části se práce zabývá možnými technologiemi 3D tisku a možností jejich využití u přestavby. Dále jsou popsány a vybrány vhodné součásti pro přestavbu. V další části je realizováno řízení ohřevu podložky, trysky a řízení posuvu drátu pomocí softwaru TwinCat od společnosti Beckhoff na průmyslovém počítači. Výsledkem práce by měla být oživená 3D tiskárna. This thesis deals with rebuilding of engraving machine to 3D pri...

  4. Anti-3D Weapon Model Detection for Safe 3D Printing Based on Convolutional Neural Networks and D2 Shape Distribution

    Directory of Open Access Journals (Sweden)

    Giao N. Pham

    2018-03-01

    Full Text Available With the development of 3D printing, weapons are easily printed without any restriction from the production managers. Therefore, anti-3D weapon model detection is necessary issue in safe 3D printing to prevent the printing of 3D weapon models. In this paper, we would like to propose an anti-3D weapon model detection algorithm to prevent the printing of anti-3D weapon models for safe 3D printing based on the D2 shape distribution and an improved convolutional neural networks (CNNs. The purpose of the proposed algorithm is to detect anti-3D weapon models when they are used in 3D printing. The D2 shape distribution is computed from random points on the surface of a 3D weapon model and their geometric features in order to construct a D2 vector. The D2 vector is then trained by improved CNNs. The CNNs are used to detect anti-3D weapon models for safe 3D printing by training D2 vectors which have been constructed from the D2 shape distribution of 3D weapon models. Experiments with 3D weapon models proved that the D2 shape distribution of 3D weapon models in the same class is the same. Training and testing results also verified that the accuracy of the proposed algorithm is higher than the conventional works. The proposed algorithm is applied in a small application, and it could detect anti-3D weapon models for safe 3D printing.

  5. Quantitative comparison of 2D and 3D late gadolinium enhancement MR imaging in patients with Fabry disease and hypertrophic cardiomyopathy.

    Science.gov (United States)

    Morsbach, F; Gordic, S; Gruner, C; Niemann, M; Goetti, R; Gotschy, A; Kozerke, S; Alkadhi, H; Manka, R

    2016-08-15

    This study aims to determine whether the quantification of myocardial fibrosis in patients with Fabry disease (FD) and hypertrophic cardiomyopathy (HCM) using a late gadolinium enhancement (LGE) singlebreath-hold three-dimensional (3D) inversion recovery magnetic resonance (MR) imaging sequence is comparable with a clinically established two-dimensional (2D) multi-breath-hold sequence. In this retrospective, IRB-approved study, 40 consecutive patients (18 male; mean age 50±17years) with Fabry disease (n=18) and HCM (n=22) underwent MR imaging at 1.5T. Spatial resolution was the same for 3D and 2D images (field-of-view, 350×350mm(2); in-plane-resolution, 1.2×1.2mm(2); section-thickness, 8mm). Datasets were analyzed for subjective image quality; myocardial and fibrotic mass, and total fibrotic tissue percentage were quantified. There was no significant difference in subjective image quality between 3D and 2D acquisitions (P=0.1 and P=0.3) for either disease. In patients with Fabry disease there were no significant differences between 3D and 2D acquisitions for myocardial mass (P=0.55), fibrous tissue mass (P=0.89), and total fibrous percentage (P=0.67), with good agreement between acquisitions according to Bland-Altman analyses. In patients with HCM there were also no significant differences between acquisitions for myocardial mass (P=0.48), fibrous tissue mass (P=0.56), and total fibrous percentage (P=0.67), with good agreement according to Bland-Altman analyses. Acquisition time was significantly shorter for 3D (25±5s) as compared to the 2D sequence (349±62s, P<0.001). In patients with Fabry disease and HCM, 3D LGE imaging provides equivalent diagnostic information in regard to quantification of myocardial fibrosis as compared with a standard 2D sequence, but at superior acquisition speed. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Evaluation of low-grade glioma structural changes after chemotherapy using DTI-based histogram analysis and functional diffusion maps

    Energy Technology Data Exchange (ETDEWEB)

    Castellano, Antonella; Iadanza, Antonella; Falini, Andrea [San Raffaele Scientific Institute and Vita-Salute San Raffaele University, Neuroradiology Unit and CERMAC, Milano (Italy); Donativi, Marina [University of Salento, Department of Mathematics and Physics ' ' Ennio De Giorgi' ' and A.D.A.M. (Advanced Data Analysis in Medicine), Lecce (Italy); Ruda, Roberta; Bertero, Luca; Soffietti, Riccardo [University of Torino, Department of Neuro-oncology, Turin (Italy); De Nunzio, Giorgio [University of Salento, Department of Mathematics and Physics ' ' Ennio De Giorgi' ' and A.D.A.M. (Advanced Data Analysis in Medicine), Lecce (Italy); INFN (National Institute of Nuclear Physics), Lecce (Italy); Riva, Marco; Bello, Lorenzo [Universita degli Studi di Milano, Milan, and Humanitas Research Hospital, Department of Medical Biotechnology and Translational Medicine, Rozzano, MI (Italy); Rucco, Matteo [University of Camerino, School of Science and Technology, Computer Science Division, Camerino, MC (Italy)

    2016-05-15

    To explore the role of diffusion tensor imaging (DTI)-based histogram analysis and functional diffusion maps (fDMs) in evaluating structural changes of low-grade gliomas (LGGs) receiving temozolomide (TMZ) chemotherapy. Twenty-one LGG patients underwent 3T-MR examinations before and after three and six cycles of dose-dense TMZ, including 3D-fluid-attenuated inversion recovery (FLAIR) sequences and DTI (b = 1000 s/mm{sup 2}, 32 directions). Mean diffusivity (MD), fractional anisotropy (FA), and tensor-decomposition DTI maps (p and q) were obtained. Histogram and fDM analyses were performed on co-registered baseline and post-chemotherapy maps. DTI changes were compared with modifications of tumour area and volume [according to Response Assessment in Neuro-Oncology (RANO) criteria], and seizure response. After three cycles of TMZ, 20/21 patients were stable according to RANO criteria, but DTI changes were observed in all patients (Wilcoxon test, P ≤ 0.03). After six cycles, DTI changes were more pronounced (P ≤ 0.005). Seventy-five percent of patients had early seizure response with significant improvement of DTI values, maintaining stability on FLAIR. Early changes of the 25th percentiles of p and MD predicted final volume change (R{sup 2} = 0.614 and 0.561, P < 0.0005, respectively). TMZ-related changes were located mainly at tumour borders on p and MD fDMs. DTI-based histogram and fDM analyses are useful techniques to evaluate the early effects of TMZ chemotherapy in LGG patients. (orig.)

  7. CASTLE3D - A Computer Aided System for Labelling Archaeological Excavations in 3D

    Science.gov (United States)

    Houshiar, H.; Borrmann, D.; Elseberg, J.; Nüchter, A.; Näth, F.; Winkler, S.

    2015-08-01

    Documentation of archaeological excavation sites with conventional methods and tools such as hand drawings, measuring tape and archaeological notes is time consuming. This process is prone to human errors and the quality of the documentation depends on the qualification of the archaeologist on site. Use of modern technology and methods in 3D surveying and 3D robotics facilitate and improve this process. Computer-aided systems and databases improve the documentation quality and increase the speed of data acquisition. 3D laser scanning is the state of the art in modelling archaeological excavation sites, historical sites and even entire cities or landscapes. Modern laser scanners are capable of data acquisition of up to 1 million points per second. This provides a very detailed 3D point cloud of the environment. 3D point clouds and 3D models of an excavation site provide a better representation of the environment for the archaeologist and for documentation. The point cloud can be used both for further studies on the excavation and for the presentation of results. This paper introduces a Computer aided system for labelling archaeological excavations in 3D (CASTLE3D). Consisting of a set of tools for recording and georeferencing the 3D data from an excavation site, CASTLE3D is a novel documentation approach in industrial archaeology. It provides a 2D and 3D visualisation of the data and an easy-to-use interface that enables the archaeologist to select regions of interest and to interact with the data in both representations. The 2D visualisation and a 3D orthogonal view of the data provide cuts of the environment that resemble the traditional hand drawings. The 3D perspective view gives a realistic view of the environment. CASTLE3D is designed as an easy-to-use on-site semantic mapping tool for archaeologists. Each project contains a predefined set of semantic information that can be used to label findings in the data. Multiple regions of interest can be joined under

  8. Do-It-Yourself: 3D Models of Hydrogenic Orbitals through 3D Printing

    Science.gov (United States)

    Griffith, Kaitlyn M.; de Cataldo, Riccardo; Fogarty, Keir H.

    2016-01-01

    Introductory chemistry students often have difficulty visualizing the 3-dimensional shapes of the hydrogenic electron orbitals without the aid of physical 3D models. Unfortunately, commercially available models can be quite expensive. 3D printing offers a solution for producing models of hydrogenic orbitals. 3D printing technology is widely…

  9. 3D motion graphics for 2D artists conquering the 3rd dimension

    CERN Document Server

    Byrne, Bill

    2011-01-01

    Add 3D to your mograph skillset! For the experienced 2D artist, this lavishly illustrated, 4 color book presents the essentials to building and compositing 3D elements into your 2D world of film and broadcast. Concepts and techniques are presented in concise, step-by-step tutorials, hundreds of which are featured throughout. Featured applications include Photoshop, Illustrator, After Effects, and Cinema 4D. Lessons include exploring the expanded 3D functionality of the Adobe Creative Suite applications (After Effects, Photoshop, and Illustrator) through a series of practical tutorials. More

  10. 3D Systems” ‘Stuck in the Middle’ of the 3D Printer Boom?

    NARCIS (Netherlands)

    A. Hoffmann (Alan)

    2014-01-01

    textabstract3D Systems, the pioneer of 3D printing, predicted a future where "kids from 8 to 80" could design and print their ideas at home. By 2013, 9 years after the creation of the first working 3D printer, there were more than 30 major 3D printing companies competing for market share. 3DS and

  11. FUN3D Manual: 13.3

    Science.gov (United States)

    Biedron, Robert T.; Carlson, Jan-Renee; Derlaga, Joseph M.; Gnoffo, Peter A.; Hammond, Dana P.; Jones, William T.; Kleb, Bil; Lee-Rausch, Elizabeth M.; Nielsen, Eric J.; Park, Michael A.; hide

    2018-01-01

    This manual describes the installation and execution of FUN3D version 13.3, including optional dependent packages. FUN3D is a suite of computational fluid dynamics simulation and design tools that uses mixed-element unstructured grids in a large number of formats, including structured multiblock and overset grid systems. A discretely-exact adjoint solver enables efficient gradient-based design and grid adaptation to reduce estimated discretization error. FUN3D is available with and without a reacting, real-gas capability. This generic gas option is available only for those persons that qualify for its beta release status.

  12. 3D deblending of simultaneous source data based on 3D multi-scale shaping operator

    Science.gov (United States)

    Zu, Shaohuan; Zhou, Hui; Mao, Weijian; Gong, Fei; Huang, Weilin

    2018-04-01

    We propose an iterative three-dimensional (3D) deblending scheme using 3D multi-scale shaping operator to separate 3D simultaneous source data. The proposed scheme is based on the property that signal is coherent, whereas interference is incoherent in some domains, e.g., common receiver domain and common midpoint domain. In two-dimensional (2D) blended record, the coherency difference of signal and interference is in only one spatial direction. Compared with 2D deblending, the 3D deblending can take more sparse constraints into consideration to obtain better performance, e.g., in 3D common receiver gather, the coherency difference is in two spatial directions. Furthermore, with different levels of coherency, signal and interference distribute in different scale curvelet domains. In both 2D and 3D blended records, most coherent signal locates in coarse scale curvelet domain, while most incoherent interference distributes in fine scale curvelet domain. The scale difference is larger in 3D deblending, thus, we apply the multi-scale shaping scheme to further improve the 3D deblending performance. We evaluate the performance of 3D and 2D deblending with the multi-scale and global shaping operators, respectively. One synthetic and one field data examples demonstrate the advantage of the 3D deblending with 3D multi-scale shaping operator.

  13. Underwater 3D filming

    Directory of Open Access Journals (Sweden)

    Roberto Rinaldi

    2014-12-01

    Full Text Available After an experimental phase of many years, 3D filming is now effective and successful. Improvements are still possible, but the film industry achieved memorable success on 3D movie’s box offices due to the overall quality of its products. Special environments such as space (“Gravity” and the underwater realm look perfect to be reproduced in 3D. “Filming in space” was possible in “Gravity” using special effects and computer graphic. The underwater realm is still difficult to be handled. Underwater filming in 3D was not that easy and effective as filming in 2D, since not long ago. After almost 3 years of research, a French, Austrian and Italian team realized a perfect tool to film underwater, in 3D, without any constrains. This allows filmmakers to bring the audience deep inside an environment where they most probably will never have the chance to be.

  14. 3D histomorphometric quantification from 3D computed tomography

    International Nuclear Information System (INIS)

    Oliveira, L.F. de; Lopes, R.T.

    2004-01-01

    The histomorphometric analysis is based on stereologic concepts and was originally applied to biologic samples. This technique has been used to evaluate different complex structures such as ceramic filters, net structures and cancellous objects that are objects with inner connected structures. The measured histomorphometric parameters of structure are: sample volume to total reconstructed volume (BV/TV), sample surface to sample volume (BS/BV), connection thickness (Tb Th ), connection number (Tb N ) and connection separation (Tb Sp ). The anisotropy was evaluated as well. These parameters constitute the base of histomorphometric analysis. The quantification is realized over cross-sections recovered by cone beam reconstruction, where a real-time microfocus radiographic system is used as tomographic system. The three-dimensional (3D) histomorphometry, obtained from tomography, corresponds to an evolution of conventional method that is based on 2D analysis. It is more coherent with morphologic and topologic context of the sample. This work shows result from 3D histomorphometric quantification to characterize objects examined by 3D computer tomography. The results, which characterizes the internal structures of ceramic foams with different porous density, are compared to results from conventional methods

  15. Scoops3D: software to analyze 3D slope stability throughout a digital landscape

    Science.gov (United States)

    Reid, Mark E.; Christian, Sarah B.; Brien, Dianne L.; Henderson, Scott T.

    2015-01-01

    The computer program, Scoops3D, evaluates slope stability throughout a digital landscape represented by a digital elevation model (DEM). The program uses a three-dimensional (3D) method of columns approach to assess the stability of many (typically millions) potential landslides within a user-defined size range. For each potential landslide (or failure), Scoops3D assesses the stability of a rotational, spherical slip surface encompassing many DEM cells using a 3D version of either Bishop’s simplified method or the Ordinary (Fellenius) method of limit-equilibrium analysis. Scoops3D has several options for the user to systematically and efficiently search throughout an entire DEM, thereby incorporating the effects of complex surface topography. In a thorough search, each DEM cell is included in multiple potential failures, and Scoops3D records the lowest stability (factor of safety) for each DEM cell, as well as the size (volume or area) associated with each of these potential landslides. It also determines the least-stable potential failure for the entire DEM. The user has a variety of options for building a 3D domain, including layers or full 3D distributions of strength and pore-water pressures, simplistic earthquake loading, and unsaturated suction conditions. Results from Scoops3D can be readily incorporated into a geographic information system (GIS) or other visualization software. This manual includes information on the theoretical basis for the slope-stability analysis, requirements for constructing and searching a 3D domain, a detailed operational guide (including step-by-step instructions for using the graphical user interface [GUI] software, Scoops3D-i) and input/output file specifications, practical considerations for conducting an analysis, results of verification tests, and multiple examples illustrating the capabilities of Scoops3D. Easy-to-use software installation packages are available for the Windows or Macintosh operating systems; these packages

  16. Comparison of 3- and 20-Gradient Direction Diffusion-Weighted Imaging in a Clinical Subacute Cohort of Patients with Transient Ischemic Attack: Application of Standard Vendor Protocols for Lesion Detection and Final Infarct Size Projection

    Directory of Open Access Journals (Sweden)

    Inger Havsteen

    2017-12-01

    Full Text Available ObjectiveDiffusion tensor imaging may aid brain ischemia assessment but is more time consuming than conventional diffusion-weighted imaging (DWI. We compared 3-gradient direction DWI (3DWI and 20-gradient direction DWI (20DWI standard vendor protocols in a hospital-based prospective cohort of patients with transient ischemic attack (TIA for lesion detection, lesion brightness, predictability of persisting infarction, and final infarct size.MethodsWe performed 3T-magnetic resonance imaging including diffusion and T2-fluid attenuated inversion recovery (FLAIR within 72 h and 8 weeks after ictus. Qualitative lesion brightness was assessed by visual inspection. We measured lesion area and brightness with manual regions of interest and compared with homologous normal tissue.Results117 patients with clinical TIA showed 78 DWI lesions. 2 lesions showed only on 3DWI. No lesions were uniquely 20DWI positive. 3DWI was visually brightest for 34 lesions. 12 lesions were brightest on 20DWI. The median 3DWI lesion area was larger for lesions equally bright, or brightest on 20DWI [median (IQR 39 (18–95 versus 18 (10–34 mm2, P = 0.007]. 3DWI showed highest measured relative lesion signal intensity [median (IQR 0.77 (0.48–1.17 versus 0.58 (0.34–0.81, P = 0.0006]. 3DWI relative lesion signal intensity was not correlated to absolute signal intensity, but 20DWI performed less well for low-contrast lesions. 3DWI lesion size was an independent predictor of persistent infarction. 3-gradient direction apparent diffusion coefficient areas were closest to 8-week FLAIR infarct size.Conclusion3DWI detected more lesions and had higher relative lesion SI than 20DWI. 20DWI appeared blurred and did not add information.Clinical Trial Registrationhttp://www.clinicaltrials.gov. Unique Identifier NCT01531946.

  17. MAP3D: a media processor approach for high-end 3D graphics

    Science.gov (United States)

    Darsa, Lucia; Stadnicki, Steven; Basoglu, Chris

    1999-12-01

    Equator Technologies, Inc. has used a software-first approach to produce several programmable and advanced VLIW processor architectures that have the flexibility to run both traditional systems tasks and an array of media-rich applications. For example, Equator's MAP1000A is the world's fastest single-chip programmable signal and image processor targeted for digital consumer and office automation markets. The Equator MAP3D is a proposal for the architecture of the next generation of the Equator MAP family. The MAP3D is designed to achieve high-end 3D performance and a variety of customizable special effects by combining special graphics features with high performance floating-point and media processor architecture. As a programmable media processor, it offers the advantages of a completely configurable 3D pipeline--allowing developers to experiment with different algorithms and to tailor their pipeline to achieve the highest performance for a particular application. With the support of Equator's advanced C compiler and toolkit, MAP3D programs can be written in a high-level language. This allows the compiler to successfully find and exploit any parallelism in a programmer's code, thus decreasing the time to market of a given applications. The ability to run an operating system makes it possible to run concurrent applications in the MAP3D chip, such as video decoding while executing the 3D pipelines, so that integration of applications is easily achieved--using real-time decoded imagery for texturing 3D objects, for instance. This novel architecture enables an affordable, integrated solution for high performance 3D graphics.

  18. The 3d84s and 3d84d configurations of the fourth spectrum of zinc: Zn IV

    International Nuclear Information System (INIS)

    Joshi, Y.N.; Van Kleef, T.A.M.

    1987-01-01

    The spectrum of zinc was photographed in the region 2000 A - 820 A on a 6.65 m and a 10.7 m normal incidence spectrograph using a sliding spark and a triggered spark source. The new measurements have helped us to confirm the earlier analysis of the 3d 8 4s-3d 8 4p transitions and locate the missing level 3d 8 4s 2 S 1/2 , and study the 3d 8 4p-3d 8 4d transitions. 59 out of 67 levels of the 3d 8 4d configuration have been established. Parametric least-squares-fitted calculations support the analysis. Two hundred and eight (208) additional lines have been classified in the Zn IV analysis. (orig.)

  19. Acquiring 3D scene information from 2D images

    NARCIS (Netherlands)

    Li, Ping

    2011-01-01

    In recent years, people are becoming increasingly acquainted with 3D technologies such as 3DTV, 3D movies and 3D virtual navigation of city environments in their daily life. Commercial 3D movies are now commonly available for consumers. Virtual navigation of our living environment as used on a

  20. 2D-Driven 3D Object Detection in RGB-D Images

    KAUST Repository

    Lahoud, Jean; Ghanem, Bernard

    2017-01-01

    In this paper, we present a technique that places 3D bounding boxes around objects in an RGB-D scene. Our approach makes best use of the 2D information to quickly reduce the search space in 3D, benefiting from state-of-the-art 2D object detection

  1. Apparent diffusion coefficient histogram metrics correlate with survival in diffuse intrinsic pontine glioma: a report from the Pediatric Brain Tumor Consortium

    Science.gov (United States)

    Poussaint, Tina Young; Vajapeyam, Sridhar; Ricci, Kelsey I.; Panigrahy, Ashok; Kocak, Mehmet; Kun, Larry E.; Boyett, James M.; Pollack, Ian F.; Fouladi, Maryam

    2016-01-01

    Background Diffuse intrinsic pontine glioma (DIPG) is associated with poor survival regardless of therapy. We used volumetric apparent diffusion coefficient (ADC) histogram metrics to determine associations with progression-free survival (PFS) and overall survival (OS) at baseline and after radiation therapy (RT). Methods Baseline and post-RT quantitative ADC histograms were generated from fluid-attenuated inversion recovery (FLAIR) images and enhancement regions of interest. Metrics assessed included number of peaks (ie, unimodal or bimodal), mean and median ADC, standard deviation, mode, skewness, and kurtosis. Results Based on FLAIR images, the majority of tumors had unimodal peaks with significantly shorter average survival. Pre-RT FLAIR mean, mode, and median values were significantly associated with decreased risk of progression; higher pre-RT ADC values had longer PFS on average. Pre-RT FLAIR skewness and standard deviation were significantly associated with increased risk of progression; higher pre-RT FLAIR skewness and standard deviation had shorter PFS. Nonenhancing tumors at baseline showed higher ADC FLAIR mean values, lower kurtosis, and higher PFS. For enhancing tumors at baseline, bimodal enhancement histograms had much worse PFS and OS than unimodal cases and significantly lower mean peak values. Enhancement in tumors only after RT led to significantly shorter PFS and OS than in patients with baseline or no baseline enhancement. Conclusions ADC histogram metrics in DIPG demonstrate significant correlations between diffusion metrics and survival, with lower diffusion values (increased cellularity), increased skewness, and enhancement associated with shorter survival, requiring future investigations in large DIPG clinical trials. PMID:26487690

  2. Ingestion of Sodium Bicarbonate (NaHCO3) Following a Fatiguing Bout of Exercise Accelerates Postexercise Acid-Base Balance Recovery and Improves Subsequent High-Intensity Cycling Time to Exhaustion.

    Science.gov (United States)

    Gough, Lewis A; Rimmer, Steven; Osler, Callum J; Higgins, Matthew F

    2017-10-01

    This study evaluated the ingestion of sodium bicarbonate (NaHCO 3 ) on postexercise acid-base balance recovery kinetics and subsequent high-intensity cycling time to exhaustion. In a counterbalanced, crossover design, nine healthy and active males (age: 23 ± 2 years, height: 179 ± 5 cm, body mass: 74 ± 9 kg, peak mean minute power (W peak ) 256 ± 45 W, peak oxygen uptake (V̇O 2peak ) 46 ± 8 ml.kg -1 .min -1 ) performed a graded incremental exercise test, two familiarization and two experimental trials. Experimental trials consisted of cycling to volitional exhaustion (T LIM1 ) at 100% W PEAK on two occasions (T LIM1 and T LIM2 ) interspersed by a 90 min passive recovery period. Using a double-blind approach, 30 min into a 90 min recovery period participants ingested either 0.3 g.kg -1 body mass sodium bicarbonate (NaHCO 3 ) or a placebo (PLA) containing 0.1 g.kg -1 body mass sodium chloride (NaCl) mixed with 4 ml.kg -1 tap water and 1 ml.kg -1 orange squash. The mean differences between T LIM2 and T LIM1 was larger for PLA compared with NaHCO 3 (-53 ± 53 vs. -20 ± 48 s; p = .008, d = 0.7, CI =-0.3, 1.6), indicating superior subsequent exercise time to exhaustion following NaHCO 3 . Blood lactate [Bla - ] was similar between treatments post T LIM1 , but greater for NaHCO 3 post T LIM2 and 5 min post T LIM2 . Ingestion of NaHCO 3 induced marked increases (p < .01) in both blood pH (+0.07 ± 0.02, d = 2.6, CI = 1.2, 3.7) and bicarbonate ion concentration [HCO 3 - ] (+6.8 ± 1.6 mmo.l -1 , d = 3.4, CI = 1.8, 4.7) compared with the PLA treatment, before T LIM2 . It is likely both the acceleration of recovery, and the marked increases of acid-base after T LIM1 contributed to greater T LIM2 performance compared with the PLA condition.

  3. Micro Fourier Transform Profilometry (μFTP): 3D shape measurement at 10,000 frames per second

    Science.gov (United States)

    Zuo, Chao; Tao, Tianyang; Feng, Shijie; Huang, Lei; Asundi, Anand; Chen, Qian

    2018-03-01

    Fringe projection profilometry is a well-established technique for optical 3D shape measurement. However, in many applications, it is desirable to make 3D measurements at very high speed, especially with fast moving or shape changing objects. In this work, we demonstrate a new 3D dynamic imaging technique, Micro Fourier Transform Profilometry (μFTP), which can realize an acquisition rate up to 10,000 3D frame per second (fps). The high measurement speed is achieved by the number of patterns reduction as well as high-speed fringe projection hardware. In order to capture 3D information in such a short period of time, we focus on the improvement of the phase recovery, phase unwrapping, and error compensation algorithms, allowing to reconstruct an accurate, unambiguous, and distortion-free 3D point cloud with every two projected patterns. We also develop a high-frame-rate fringe projection hardware by pairing a high-speed camera and a DLP projector, enabling binary pattern switching and precisely synchronized image capture at a frame rate up to 20,000 fps. Based on this system, we demonstrate high-quality textured 3D imaging of 4 transient scenes: vibrating cantilevers, rotating fan blades, flying bullet, and bursting balloon, which were previously difficult or even unable to be captured with conventional approaches.

  4. 3D FaceCam: a fast and accurate 3D facial imaging device for biometrics applications

    Science.gov (United States)

    Geng, Jason; Zhuang, Ping; May, Patrick; Yi, Steven; Tunnell, David

    2004-08-01

    Human faces are fundamentally three-dimensional (3D) objects, and each face has its unique 3D geometric profile. The 3D geometric features of a human face can be used, together with its 2D texture, for rapid and accurate face recognition purposes. Due to the lack of low-cost and robust 3D sensors and effective 3D facial recognition (FR) algorithms, almost all existing FR systems use 2D face images. Genex has developed 3D solutions that overcome the inherent problems in 2D while also addressing limitations in other 3D alternatives. One important aspect of our solution is a unique 3D camera (the 3D FaceCam) that combines multiple imaging sensors within a single compact device to provide instantaneous, ear-to-ear coverage of a human face. This 3D camera uses three high-resolution CCD sensors and a color encoded pattern projection system. The RGB color information from each pixel is used to compute the range data and generate an accurate 3D surface map. The imaging system uses no moving parts and combines multiple 3D views to provide detailed and complete 3D coverage of the entire face. Images are captured within a fraction of a second and full-frame 3D data is produced within a few seconds. This described method provides much better data coverage and accuracy in feature areas with sharp features or details (such as the nose and eyes). Using this 3D data, we have been able to demonstrate that a 3D approach can significantly improve the performance of facial recognition. We have conducted tests in which we have varied the lighting conditions and angle of image acquisition in the "field." These tests have shown that the matching results are significantly improved when enrolling a 3D image rather than a single 2D image. With its 3D solutions, Genex is working toward unlocking the promise of powerful 3D FR and transferring FR from a lab technology into a real-world biometric solution.

  5. 3D-modeling and 3D-printing explorations on Japanese tea ceremony utensils

    NARCIS (Netherlands)

    Levy, P.D.; Yamada, Shigeru

    2017-01-01

    In this paper, we inquire aesthetical aspects of the Japanese tea ceremony, described as the aesthetics in the imperfection, based on novel fabrication technologies: 3D-modeling and 3D-printing. To do so, 3D-printed utensils (chashaku and chasen) were iteratively designed for the ceremony and were

  6. 3D printing for dummies

    CERN Document Server

    Hausman, Kalani Kirk

    2014-01-01

    Get started printing out 3D objects quickly and inexpensively! 3D printing is no longer just a figment of your imagination. This remarkable technology is coming to the masses with the growing availability of 3D printers. 3D printers create 3-dimensional layered models and they allow users to create prototypes that use multiple materials and colors.  This friendly-but-straightforward guide examines each type of 3D printing technology available today and gives artists, entrepreneurs, engineers, and hobbyists insight into the amazing things 3D printing has to offer. You'll discover methods for

  7. Kuvaus 3D-tulostamisesta hammastekniikassa

    OpenAIRE

    Munne, Mauri; Mustonen, Tuomas; Vähäjylkkä, Jaakko

    2013-01-01

    3D-tulostaminen kehittyy nopeasti ja yleistyy koko ajan. Tulostimien tarkkuuksien kehittyessä 3D-tulostus on ottamassa myös jalansijaa hammastekniikan alalta. Tämän opinnäytetyön tarkoituksena on kuvata 3D-tulostamisen tilaa hammastekniikassa. 3D-tulostaminen on Suomessa vielä melko harvinaista, joten opinnäytetyön tavoitteena on koota yhteen kaikki mahdollinen tieto liittyen 3D-tulostamiseen hammastekniikassa. Tavoitteena on myös 3D-tulostimen testaaminen käytännössä aina suun skannaami...

  8. The dimension added by 3D scanning and 3D printing of meteorites

    Science.gov (United States)

    de Vet, S. J.

    2016-01-01

    An overview for the 3D photodocumentation of meteorites is presented, focussing on two 3D scanning methods in relation to 3D printing. The 3D photodocumention of meteorites provides new ways for the digital preservation of culturally, historically or scientifically unique meteorites. It has the potential for becoming a new documentation standard of meteorites that can exist complementary to traditional photographic documentation. Notable applications include (i.) use of physical properties in dark flight-, strewn field-, or aerodynamic modelling; (ii.) collection research of meteorites curated by different museum collections, and (iii.) public dissemination of meteorite models as a resource for educational users. The possible applications provided by the additional dimension of 3D illustrate the benefits for the meteoritics community.

  9. 3D Model Optimization of Four-Facet Drill for 3D Drilling Simulation

    Directory of Open Access Journals (Sweden)

    Buranský Ivan

    2016-09-01

    Full Text Available The article is focused on optimization of four-facet drill for 3D drilling numerical modelling. For optimization, the process of reverse engineering by PowerShape software was used. The design of four-facet drill was created in NumrotoPlus software. The modified 3D model of the drill was used in the numerical analysis of cutting forces. Verification of the accuracy of 3D models for reverse engineering was implemented using the colour deviation maps. The CAD model was in the STEP format. For simulation software, 3D model in the STEP format is ideal. STEP is a solid model. Simulation software automatically splits the 3D model into finite elements. The STEP model was therefore more suitable than the STL model.

  10. Separation and recovery of high grade Dy2O3 by solvent extraction process with DEHPA in kerosene

    International Nuclear Information System (INIS)

    Mishra, S.L.; Thakur, N.V.; Koppiker, K.S.

    1993-01-01

    During the solvent extraction (SX) fractionation of rare earths chloride obtained from monazite, a heavy RE (HRE) fraction assaying 60% Y 2 O 3 is produced. This is purified further to 93% Y 2 O 3 by another SX cycle. During this step most of Dy and Tb get separated to yield a concentrate assaying >50% Dy 2 O 3 . An attempt has been made to process this Dy rich concentrate to obtain a high grade Dy 2 O 3 by a SX route using DEHPA in kerosene. The distribution data (D vs H i + ) of Dy have been generated experimentally at various metal concentrations and similar data for other metals present (Gd, Tb, Y, Er and Ho) have been derived using a mathematical expression developed in our laboratory. Based on this information mathematical models for extraction behaviour of these HRE have been derived and used in a computer program developed for multicomponent system. This program has been utilised to optimise the process parameters to obtain 95-97% pure Dy 2 O 3 at about 90% recovery. The parameters have been experimentally confirmed and Dy 2 O 3 95.5% pure w.r.t. Tb was obtained at about 90% recovery, thus confirming the validity of the program. This paper presents data obtained during these investigations. (author). 6 refs., 5 tabs

  11. 25-Hydroxyvitamin D-3 affects vitamin D status similar to vitamin D-3 in pigs - but the meat produced has a lower content of vitamin D

    DEFF Research Database (Denmark)

    Jakobsen, Jette; Maribo, H.; Bysted, Anette

    2007-01-01

    In food databases, the specific contents of vitamin D-3 and 25-hydroxyvitamin D-3 in food have been implemented in the last 10 years. No consensus has yet been established on the relative activity between the components. Therefore, the objective of the present study was to assess the relative...... activity of 25-hydroxyvitamin D-3 compared to vitamin D-3. The design was a parallel study in pigs (n 24), which from an age of 12 weeks until slaughter 11 weeks later were fed approximately 55 mu g vitamin D/d, as vitamin D-3, in a mixture of vitamin D-3 and 25-hydroxyvitamin D-3, or 25-hydroxyvitamin D-3....... The end-points measured were plasma 25-hydroxyvitamin D-3, and in the liver and loin the content of vitamin D-3 and 25-hydroxyvitamin D-3 Vitamin D-3 and 25-hydroxyvitamin D3 in the feed did not affect 25-hydroxyvitamin D-3 in the plasma, liver or loin differently, while a significant effect was shown...

  12. Prospective study of factors influencing conditional discharge from a forensic hospital: the DUNDRUM-3 programme completion and DUNDRUM-4 recovery structured professional judgement instruments and risk.

    LENUS (Irish Health Repository)

    Davoren, Mary

    2013-01-01

    We set out to examine whether structured professional judgement instruments DUNDRUM-3 programme completion (D-3) and DUNDRUM-4 recovery (D-4) scales along with measures of risk, mental state and global function could distinguish between those forensic patients detained in a secure forensic hospital (not guilty by reason of insanity or unfit to stand trial) who were subsequently discharged by a mental health review board. We also examined the interaction between these measures and risk, need for therapeutic security and eventual conditional discharge.

  13. Intra-operative 3D imaging system for robot-assisted fracture manipulation.

    Science.gov (United States)

    Dagnino, G; Georgilas, I; Tarassoli, P; Atkins, R; Dogramadzi, S

    2015-01-01

    Reduction is a crucial step in the treatment of broken bones. Achieving precise anatomical alignment of bone fragments is essential for a good fast healing process. Percutaneous techniques are associated with faster recovery time and lower infection risk. However, deducing intra-operatively the desired reduction position is quite challenging due to the currently available technology. The 2D nature of this technology (i.e. the image intensifier) doesn't provide enough information to the surgeon regarding the fracture alignment and rotation, which is actually a three-dimensional problem. This paper describes the design and development of a 3D imaging system for the intra-operative virtual reduction of joint fractures. The proposed imaging system is able to receive and segment CT scan data of the fracture, to generate the 3D models of the bone fragments, and display them on a GUI. A commercial optical tracker was included into the system to track the actual pose of the bone fragments in the physical space, and generate the corresponding pose relations in the virtual environment of the imaging system. The surgeon virtually reduces the fracture in the 3D virtual environment, and a robotic manipulator connected to the fracture through an orthopedic pin executes the physical reductions accordingly. The system is here evaluated through fracture reduction experiments, demonstrating a reduction accuracy of 1.04 ± 0.69 mm (translational RMSE) and 0.89 ± 0.71 ° (rotational RMSE).

  14. Ultra-low friction and excellent elastic recovery of fullerene-like ...

    Indian Academy of Sciences (India)

    2017-08-24

    Aug 24, 2017 ... a high elastic recovery (∼90%), ultra-low friction coefficient (∼0.019) and low wear rate ... Y Meng et al .... [3] Liu D G, Tu J P, Gu C D, Hong C F, Chen R and Yang W S ... [7] Cumings J and Zettl A 2000 Science 289 602.

  15. 3D printing of concentrated emulsions into multiphase biocompatible soft materials.

    Science.gov (United States)

    Sommer, Marianne R; Alison, Lauriane; Minas, Clara; Tervoort, Elena; Rühs, Patrick A; Studart, André R

    2017-03-01

    3D printing via direct ink writing (DIW) is a versatile additive manufacturing approach applicable to a variety of materials ranging from ceramics over composites to hydrogels. Due to the mild processing conditions compared to other additive manufacturing methods, DIW enables the incorporation of sensitive compounds such as proteins or drugs into the printed structure. Although emulsified oil-in-water systems are commonly used vehicles for such compounds in biomedical, pharmaceutical, and cosmetic applications, printing of such emulsions into architectured soft materials has not been fully exploited and would open new possibilities for the controlled delivery of sensitive compounds. Here, we 3D print concentrated emulsions into soft materials, whose multiphase architecture allows for site-specific incorporation of both hydrophobic and hydrophilic compounds into the same structure. As a model ink, concentrated emulsions stabilized by chitosan-modified silica nanoparticles are studied, because they are sufficiently stable against coalescence during the centrifugation step needed to create a bridging network of droplets. The resulting ink is ideal for 3D printing as it displays high yield stress, storage modulus and elastic recovery, through the formation of networks of droplets as well as of gelled silica nanoparticles in the presence of chitosan. To demonstrate possible architectures, we print biocompatible soft materials with tunable hierarchical porosity containing an encapsulated hydrophobic compound positioned in specific locations of the structure. The proposed emulsion-based ink system offers great flexibility in terms of 3D shaping and local compositional control, and can potentially help address current challenges involving the delivery of incompatible compounds in biomedical applications.

  16. The 3d4-3d34p transitions of triply ionized manganese (Mn IV)

    International Nuclear Information System (INIS)

    Tchang-Brillet, W.Ue.L.; Artru, M.C.; Wyart, J.F.

    1986-01-01

    The analysis of Mn IV is extended in the wavelength range 473-847 A. A total of 600 classified lines are given, of which 372 are newly observed. All of them are due to 3d 4 -3d 3 4p transitions. Their classification and the identification of 59 new levels are supported by the parametric studies of the 3d 4 and 3d 3 4p configurations. The ground configuration 3d 4 is calculated by taking into account the effective magnetic interactions which improve by an order of magnitude the theoretical fine structure of the quintet and triplet terms. The analysis was guided by the prediction of relative line strengths in intermediate coupling. Calculated energies and LS composition are given for all levels of the configuration, 3d 4 and 3d 3 4p. (orig).

  17. 3D-MR vs. 3D-CT of the shoulder in patients with glenohumeral instability

    Energy Technology Data Exchange (ETDEWEB)

    Stillwater, Laurence; Koenig, James; Maycher, Bruce; Davidson, Michael [University of Manitoba, Winnipeg (Canada)

    2017-03-15

    To determine whether 3D-MR osseous reformats of the shoulder are equivalent to 3D-CT osseous reformats in patients with glenohumeral instability. Patients with glenohumeral instability, who were to be imaged with both CT and MRI, were prospectively selected. CT and MR were performed within 24 h of one another on 12 shoulders. Each MR study included an axial 3D isotropic VIBE sequence. The image data from the isotropic VIBE sequence were post-processed using subtraction and 3D software. CT data were post-processed using 3D software. The following measurements were obtained for both 3D-CT and 3D-MR post-processed images: height and width of the humeral head and glenoid, Hill-Sachs size and percent humeral head loss (if present), size of glenoid bone loss and percent glenoid bone loss (if present). Paired t-tests and two one-sided tests for equivalence were used to assess the differences between imaging modalities and equivalence. The measurement differences from the 3D-CT and 3D-MR post-processed images were not statistically significant. The measurement differences for humeral height, glenoid height and glenoid width were borderline statistically significant; however, using any adjustment for multiple comparisons, this failed to be significant. Using an equivalence margin of 1 mm for measurements and 1.5% for percent bone loss, the 3D-MR and 3D-CT post-processed images were equivalent. Three-dimensional-MR osseous models of the shoulder using a 3D isotropic VIBE sequence were equivalent to 3D-CT osseous models, and the differences between modalities were not statistically significant. (orig.)

  18. 3D geometric phase analysis and its application in 3D microscopic morphology measurement

    Science.gov (United States)

    Zhu, Ronghua; Shi, Wenxiong; Cao, Quankun; Liu, Zhanwei; Guo, Baoqiao; Xie, Huimin

    2018-04-01

    Although three-dimensional (3D) morphology measurement has been widely applied on the macro-scale, there is still a lack of 3D measurement technology on the microscopic scale. In this paper, a microscopic 3D measurement technique based on the 3D-geometric phase analysis (GPA) method is proposed. In this method, with machine vision and phase matching, the traditional GPA method is extended to three dimensions. Using this method, 3D deformation measurement on the micro-scale can be realized using a light microscope. Simulation experiments were conducted in this study, and the results demonstrate that the proposed method has a good anti-noise ability. In addition, the 3D morphology of the necking zone in a tensile specimen was measured, and the results demonstrate that this method is feasible.

  19. 2D/3D/4D ULTRASOUND IN INFERTILITY MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Uršula Reš-Muravec

    2018-02-01

    Ultrasound in infertility diagnostics: Ultrasound is used for examination of uterus, tubes, ovaries and peritoneal cause of infertility. It can be used in different menstrual phases: proliferative, periovulatory and secretory phase. Examination of uterus: A 2D scan can measure the size of the uterus (length, width and depth and a 2D flow (colour and power doppler. With 3D technology we can measure the whole volume with VOCAL (virtual organ computer-aided analysis and 3D circulation with the index (VI – vascular index, FI – flow index and VFI – vascular flow index in the uterus. A 2D scan can help us define uterine malformations, fibroids and adenomyosis to a certain extent. However, a 3D scan offers more accurate diagnosis of these malformations. Endometrium is examined separately. With 2D the width is measured and morphology and focal lesions (polyp, fibroids, adhesions are examined. With 3D the real sagital plane for the width measurement can be defined . We can measure the volume of endometrium and subendometrium and 3D circulation in endometrium and subendometrium. The FIS (f luid instlation sonography is very useful when examining the endometrium; saline or gel can be used for uterine instalation. We can measure and define the position of the structures in the endometrium more accurately when they are surrouned by saline or gel. We can view these structures with a surface view, similar to the one used for hysteroscopy. With this information we can explain the pathology to the patient and easily plan the surgical procedures. Examination of the tubes: With 2D US we can see the tubes in the pelvis only if there are dilatations, but sometimes it is difficult to distinguish them from the neighbouring forma- tions. With a 3D ultrasound we can define the shape and continuity of the tube and we can view the tube from different angles (inversion mode. Different contrast media are used for determining tubal patency. Tubal patency can be diagnosed with 2D Hy

  20. 3D Deep Learning Angiography (3D-DLA) from C-arm Conebeam CT.

    Science.gov (United States)

    Montoya, J C; Li, Y; Strother, C; Chen, G-H

    2018-05-01

    Deep learning is a branch of artificial intelligence that has demonstrated unprecedented performance in many medical imaging applications. Our purpose was to develop a deep learning angiography method to generate 3D cerebral angiograms from a single contrast-enhanced C-arm conebeam CT acquisition in order to reduce image artifacts and radiation dose. A set of 105 3D rotational angiography examinations were randomly selected from an internal data base. All were acquired using a clinical system in conjunction with a standard injection protocol. More than 150 million labeled voxels from 35 subjects were used for training. A deep convolutional neural network was trained to classify each image voxel into 3 tissue types (vasculature, bone, and soft tissue). The trained deep learning angiography model was then applied for tissue classification into a validation cohort of 8 subjects and a final testing cohort of the remaining 62 subjects. The final vasculature tissue class was used to generate the 3D deep learning angiography images. To quantify the generalization error of the trained model, we calculated the accuracy, sensitivity, precision, and Dice similarity coefficients for vasculature classification in relevant anatomy. The 3D deep learning angiography and clinical 3D rotational angiography images were subjected to a qualitative assessment for the presence of intersweep motion artifacts. Vasculature classification accuracy and 95% CI in the testing dataset were 98.7% (98.3%-99.1%). No residual signal from osseous structures was observed for any 3D deep learning angiography testing cases except for small regions in the otic capsule and nasal cavity compared with 37% (23/62) of the 3D rotational angiographies. Deep learning angiography accurately recreated the vascular anatomy of the 3D rotational angiography reconstructions without a mask. Deep learning angiography reduced misregistration artifacts induced by intersweep motion, and it reduced radiation exposure

  1. A novel 3D absorption correction method for quantitative EDX-STEM tomography

    International Nuclear Information System (INIS)

    Burdet, Pierre; Saghi, Z.; Filippin, A.N.; Borrás, A.; Midgley, P.A.

    2016-01-01

    This paper presents a novel 3D method to correct for absorption in energy dispersive X-ray (EDX) microanalysis of heterogeneous samples of unknown structure and composition. By using STEM-based tomography coupled with EDX, an initial 3D reconstruction is used to extract the location of generated X-rays as well as the X-ray path through the sample to the surface. The absorption correction needed to retrieve the generated X-ray intensity is then calculated voxel-by-voxel estimating the different compositions encountered by the X-ray. The method is applied to a core/shell nanowire containing carbon and oxygen, two elements generating highly absorbed low energy X-rays. Absorption is shown to cause major reconstruction artefacts, in the form of an incomplete recovery of the oxide and an erroneous presence of carbon in the shell. By applying the correction method, these artefacts are greatly reduced. The accuracy of the method is assessed using reference X-ray lines with low absorption. - Highlights: • A novel 3D absorption correction method is proposed for 3D EDX-STEM tomography. • The absorption of X-rays along the path to the surface is calculated voxel-by-voxel. • The method is applied on highly absorbed X-rays emitted from a core/shell nanowire. • Absorption is shown to cause major artefacts in the reconstruction. • Using the absorption correction method, the reconstruction artefacts are greatly reduced.

  2. A novel 3D absorption correction method for quantitative EDX-STEM tomography

    Energy Technology Data Exchange (ETDEWEB)

    Burdet, Pierre, E-mail: pierre.burdet@a3.epfl.ch [Department of Materials Science and Metallurgy, University of Cambridge, Charles Babbage Road 27, Cambridge CB3 0FS, Cambridgeshire (United Kingdom); Saghi, Z. [Department of Materials Science and Metallurgy, University of Cambridge, Charles Babbage Road 27, Cambridge CB3 0FS, Cambridgeshire (United Kingdom); Filippin, A.N.; Borrás, A. [Nanotechnology on Surfaces Laboratory, Materials Science Institute of Seville (ICMS), CSIC-University of Seville, C/ Americo Vespucio 49, 41092 Seville (Spain); Midgley, P.A. [Department of Materials Science and Metallurgy, University of Cambridge, Charles Babbage Road 27, Cambridge CB3 0FS, Cambridgeshire (United Kingdom)

    2016-01-15

    This paper presents a novel 3D method to correct for absorption in energy dispersive X-ray (EDX) microanalysis of heterogeneous samples of unknown structure and composition. By using STEM-based tomography coupled with EDX, an initial 3D reconstruction is used to extract the location of generated X-rays as well as the X-ray path through the sample to the surface. The absorption correction needed to retrieve the generated X-ray intensity is then calculated voxel-by-voxel estimating the different compositions encountered by the X-ray. The method is applied to a core/shell nanowire containing carbon and oxygen, two elements generating highly absorbed low energy X-rays. Absorption is shown to cause major reconstruction artefacts, in the form of an incomplete recovery of the oxide and an erroneous presence of carbon in the shell. By applying the correction method, these artefacts are greatly reduced. The accuracy of the method is assessed using reference X-ray lines with low absorption. - Highlights: • A novel 3D absorption correction method is proposed for 3D EDX-STEM tomography. • The absorption of X-rays along the path to the surface is calculated voxel-by-voxel. • The method is applied on highly absorbed X-rays emitted from a core/shell nanowire. • Absorption is shown to cause major artefacts in the reconstruction. • Using the absorption correction method, the reconstruction artefacts are greatly reduced.

  3. MR features of the developing perianterior horn structure including subcallosal fasciculus in infants and children

    International Nuclear Information System (INIS)

    Utsunomiya, Hidetsuna; Nakamura, Yasuhiro

    2007-01-01

    To describe the changes in the magnetic resonance (MR) signal of the perianterior horn structure (PAS) with increasing age, we studied 69 infants and children aged between 3 days and 9.4 years (average: 2.8 years) without any neurological deficits. T1- and T2-weighted images and FLAIR (fluid attenuation inversion recovery) images were obtained in the axial plane. Based on a comparison of the intensity of the PAS with that of the cortex in each sequence (T1-WI/FLAIR/T2-WI), we classified the signal-intensity patterns into four types: I, low/low/high; II, low/high/high; III, iso/high/high; IV, high/low/low. Signal-intensity types I, II, III and IV were seen in 22, 8, 17, and 22 subjects, respectively, with younger subjects showing type I or II intensity patterns and older subjects showing type III or IV. In addition, T1-weighted and FLAIR images of subjects with a type I intensity pattern showed a rim of an isointensity component around the PAS that histologically coincided with migrating glial cells. The low-intensity area on FLAIR and T2-WI images of subjects with a type IV intensity pattern may represent myelinated fibers of the subcallosal fasciculus (ScF). The intensity of the MR signals of the PAS changes with increasing age, and this change may reflect histological features. A better understanding of these characteristics may help us to clarify myelination abnormalities, particularly those related to the ScF in the frontal lobe in infants and children. (orig.)

  4. 3D-grafiikka ja pelimoottorit

    OpenAIRE

    Sillanpää, Otto

    2014-01-01

    Tässä opinnäytetyössä tutkitaan miten 3D-mallit saadaan sellaiseen muotoon, että ne olisivat käytettävissä eri pelimoottoreissa. Tutkimuksen tarkoituksena on selvittää, miten luodaan 3D-malleja pelimoottoreihin, sekä miten 3D-mallinnusohjelmat ja pelimoottorit eroavat toisistaan, kun käsitellään 3D-malleja. Tässä työssä pelimoottoreina toimivat Valven Source sekä Epic Gamesin Unreal Engine 3. 3D-mallinnusohjelmista käytössä olivat Autodeskin 3ds Max 2014 ja Blender Foundationin Blender 2.7...

  5. Reactive flow simulation in complex 3D geometries using the COM3D code

    International Nuclear Information System (INIS)

    Breitung, W.; Kotchourko, A.; Veser, A.; Scholtyssek, W.

    1999-01-01

    The COM3D code, under development at the Forschungszentrum Karlsruhe (FZK), is a 3-d CFD code to describe turbulent combustion phenomena in complex geometries. It is intended to be part of the advanced integral code system for containment analysis (INCA) which includes in addition GASFLOW for distribution calculations, V3D for slow combustion and DET3D for detonation analysis. COM3D uses a TVD-solver and optional models for turbulence, chemistry and thermodynamics. The hydrodynamic model considers mass, momentum and energy conservation. Advanced procedures were provided to facilitate grid-development for complex 3-d structures. COM3D was validated on experiments performed on different scales with generally good agreement for important physical quantities. The code was applied to combustion analysis of a large PWR. The initial conditions were obtained from a GASFLOW distribution analysis for a LOOP scenario. Results are presented concerning flame propagation and pressure evolution in the containment which clearly demonstrate the effects of internal structures, their influence on turbulence formation and consequences for local loads. (author)

  6. Damage of DNA by radiation and it's recovery, 3

    International Nuclear Information System (INIS)

    Narita, Noboru; Matsuura, Tomio; Sato, Hiroyuki.

    1974-01-01

    The damage and recovery of DNA was investigated by the incorporation of thymine derivatives (DHT, I trans, II trans, cis and glycol) into exponentially growing Tetrahymena cells. The strain employed was Tetrahymena pyriformis, Variety I, mating type IV. It is well known that these thymine derivatives are induced in vivo by radiation. The in vivo damage of DNA induced by radiation, and its recovery, were confirmed experimentally by means of gradient separation of sucrose density and by analytical ultra centrifugation (UVC). The recovery of DNA, its excision repair and its recombinational repair were compared with the recovery of Bacillus subtilis whose recovery kinetics were already known. 1) The damage of DNA was more sensitive to glycol than to II trans and cis. On the other hand, DHT is not sensitive for breaking DNA strand. 2) In its recovery damaged DNA was no more sensitive to glycol than to hhp as was true for Bacillus subtilis. (author)

  7. Stereoselective virtual screening of the ZINC database using atom pair 3D-fingerprints.

    Science.gov (United States)

    Awale, Mahendra; Jin, Xian; Reymond, Jean-Louis

    2015-01-01

    Tools to explore large compound databases in search for analogs of query molecules provide a strategically important support in drug discovery to help identify available analogs of any given reference or hit compound by ligand based virtual screening (LBVS). We recently showed that large databases can be formatted for very fast searching with various 2D-fingerprints using the city-block distance as similarity measure, in particular a 2D-atom pair fingerprint (APfp) and the related category extended atom pair fingerprint (Xfp) which efficiently encode molecular shape and pharmacophores, but do not perceive stereochemistry. Here we investigated related 3D-atom pair fingerprints to enable rapid stereoselective searches in the ZINC database (23.2 million 3D structures). Molecular fingerprints counting atom pairs at increasing through-space distance intervals were designed using either all atoms (16-bit 3DAPfp) or different atom categories (80-bit 3DXfp). These 3D-fingerprints retrieved molecular shape and pharmacophore analogs (defined by OpenEye ROCS scoring functions) of 110,000 compounds from the Cambridge Structural Database with equal or better accuracy than the 2D-fingerprints APfp and Xfp, and showed comparable performance in recovering actives from decoys in the DUD database. LBVS by 3DXfp or 3DAPfp similarity was stereoselective and gave very different analogs when starting from different diastereomers of the same chiral drug. Results were also different from LBVS with the parent 2D-fingerprints Xfp or APfp. 3D- and 2D-fingerprints also gave very different results in LBVS of folded molecules where through-space distances between atom pairs are much shorter than topological distances. 3DAPfp and 3DXfp are suitable for stereoselective searches for shape and pharmacophore analogs of query molecules in large databases. Web-browsers for searching ZINC by 3DAPfp and 3DXfp similarity are accessible at www.gdb.unibe.ch and should provide useful assistance to drug

  8. Recovery after local extinction: factors affecting re-establishment of alpine lake zooplankton.

    Science.gov (United States)

    Knapp, Roland A; Sarnelle, Orlando

    2008-12-01

    The introduction of fishes into naturally fishless mountain lakes often results in the extirpation of large-bodied zooplankton species. The ability to predict whether or not particular species will recover following fish removal is critically important for the design and implementation of lake restoration efforts but is currently not possible because of a lack of information on what factors affect recovery. The objective of this study was to identify the factors influencing recovery probability in two large-bodied zooplankton species following fish removal. We predicted that (1) Daphnia melanica would have a higher probability of recovery than Hesperodiaptomus shoshone due to differences in reproductive mode (D. melanica is parthenogenetic, H. shoshone is obligately sexual), (2) recovery probability would be a decreasing function of fish residence time due to the negative relationship between fish residence time and size of the egg bank, and (3) recovery probability would be an increasing function of lake depth as a consequence of a positive relationship between lake depth and egg bank size. To test these predictions, we sampled contemporary zooplankton populations and collected paleolimnological data from 44 naturally fishless lakes that were stocked with trout for varying lengths of time before reverting to a fishless condition. D. melanica had a significantly higher probability of recovery than did H. shoshone (0.82 vs. 0.54, respectively). The probability of recovery for H. shoshone was also significantly influenced by lake depth, fish residence time, and elevation, but only elevation influenced the probability of recovery in D. melanica. These results are consistent with between-species differences in reproductive mode combined with the much greater longevity of diapausing eggs in D. melanica than in H. shoshone. Our data also suggest that H. shoshone will often fail to recover in lakes with fish residence times exceeding 50 years.

  9. 3D Hilbert Space Filling Curves in 3D City Modeling for Faster Spatial Queries

    DEFF Research Database (Denmark)

    Ujang, Uznir; Antón Castro, Francesc/François; Azri, Suhaibah

    2014-01-01

    The advantages of three dimensional (3D) city models can be seen in various applications including photogrammetry, urban and regional planning, computer games, etc. They expand the visualization and analysis capabilities of Geographic Information Systems on cities, and they can be developed using...... method, retrieving portions of and especially searching these 3D city models, will not be done optimally. Even though current developments are based on an open data model allotted by the Open Geospatial Consortium (OGC) called CityGML, its XML-based structure makes it challenging to cluster the 3D urban...... objects. In this research, the authors propose an opponent data constellation technique of space-filling curves (3D Hilbert curves) for 3D city model data representation. Unlike previous methods, that try to project 3D or n-dimensional data down to 2D or 3D using Principal Component Analysis (PCA...

  10. Synthesis of cefepime-d3 and cefepime-d8

    International Nuclear Information System (INIS)

    Kamachi, Hajime; Okita, Takaaki; Tsuno, Takashi; Naito, Takayuki

    1990-01-01

    Synthesis of cefepime-d 3 (6a) and cefepime-d 8 (6b) is described. Diphenylmethyl 7-benzylideneamino-3-chloromethyl-3-cephem-4-carboxylate (2) was treated with sodium iodide to afford the iodide 3, which was without isolation, allowed to react with N-methyl-d 3 -pyrrolidine to give the quaternary salt 4a. Deblocking of 4a with HCO 2 H and HCl gave 7-amino-3-(N-methyl-d3-pyrrolidinio)methyl-3-cephem-4-carboxylate hydrochloride (5a). Acylation of 5a with benzotriazol-1-yl (Z)-2-(2-aminothiazol-4-yl)-2-methoxyiminoacetate followed by treatment with dil. H 2 SO 4 afforded 6a sulfate. In the same way, 6b was synthesized using N-methyl-pyrrolidine-d 8 . (author)

  11. Using one hybrid 3D-1D-3D approach for the conceptual design of WCCB blanket for CFETR

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Kecheng; Zhang, Xiaokang [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui, 230031 (China); University of Science and Technology of China, Hefei, Anhui, 230027 (China); Li, Jia [University of Science and Technology of China, Hefei, Anhui, 230027 (China); Ma, Xuebin [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui, 230031 (China); University of Science and Technology of China, Hefei, Anhui, 230027 (China); Liu, Songlin, E-mail: slliu@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui, 230031 (China); University of Science and Technology of China, Hefei, Anhui, 230027 (China)

    2017-01-15

    Highlights: • The Hybrid 3D-1D-3D approach is used for radial building design of WCCB. • Nuclear heat obtained by this method agrees well with 3D neutronics results. • The final results of temperature and TBR satisfy with the requirements. • All the results show that this approach is high efficiency and high reliability. - Abstract: A hybrid 3D-1D-3D approach is proposed for the conceptual design of a blanket. Firstly, the neutron wall loading (NWL) of each blanket module is obtained through a neutronics calculation employing a 3D model, which contains the geometry outline of in-vacuum vessel components and the exact neutron source distribution. Secondly, a 1D cylindrical model with the blanket module containing a detailed radial building is adopted for the neutronics analysis, with the aim of calculating the tritium breeding ratio (TBR) and nuclear heating. Being normalized to the NWL, the nuclear heating is transferred to a 2D model for thermal-hydraulics analysis using the FLUENT code. Through a series analysis of nuclear-thermal iterations that considers the tritium breeding ratio (TBR) and thermal performance as optimization objectives, the optimized radial building of each module surrounding plasma can be obtained. Thirdly, the 3D structural design of each module is established by adding side walls, cover plates, stiffening plates, and other components based on the radial building. The 3D neutronics and thermal-hydraulics using the detailed blanket modules are re-analyzed. This approach has been successfully applied to the design of a water-cooled ceramic breeder blanket for the Chinese Fusion Engineering Test Reactor (CFETR). The radial building of each blanket module surrounding plasma is optimized. The global tritium breeding ratio (TBR) calculated by the 3D neutronics analysis is 1.21, and the temperature of all materials in the 3D blanket structure is below the upper limits. As indicated by the comparison of the 1D and 3D neutronics and thermal

  12. Modelling 3D spatial objects in a geo-DBMS using a 3D primitive

    Science.gov (United States)

    Arens, Călin; Stoter, Jantien; van Oosterom, Peter

    2005-03-01

    There is a growing interest in modelling the world in three dimensions, both in applications and in science. At the same time, geographical information systems are changing into integrated architecture in which administrative and spatial data are maintained in one environment. It is for this reason that mainstream Data Base Management Systems (DBMSs) have implemented spatial data types according to the 'Simple Feature Specifications for SQL', described by the OpenGeospatial Consortium. However, these specifications are 2D, as indeed are the implementations in DBMSs. At the Section GIS Technology of TU Delft, research has been carried out in which a 3D primitive was implemented in a DBMS (Oracle Spatial). To explore the possibilities and complications, a fairly simple 3D primitive was chosen to start with: a polyhedron. In the future the study will be extended with more complex primitives, the ultimate aim being to build 3D models with features closer to the real world. Besides the data structure, a validation function was developed to check the geometric accuracy of the data. Rules for validation were established and translated into prototype implementations with the aid of literature. In order to manipulate the data, a list of useful 3D functions was specified. Most of these were translated into algorithms, which were implemented in the DBMS. The algorithms for these functions were obtained from the relevant literature. The research also comprised a comparative performance test on spatial indexing in 2D and 3D, using an R-tree. Finally, existing software was used to visualize 3D objects structured with the implemented 3D primitive. This research is a first attempt to implement a true 3D primitive in a DBMS. Future research will focus on extending and improving the implementations and on optimizing maintenance and query of 3D objects in DBMSs.

  13. Comparison of modern 3D and 2D MR imaging sequences of the wrist at 3 Tesla

    International Nuclear Information System (INIS)

    Rehnitz, C.; Klaan, B.; Amarteifio, E.; Kauczor, H.U.; Weber, M.A.; Stillfried, F. von; Burkholder, I.

    2016-01-01

    To compare the image quality of modern 3 D and 2 D sequences for dedicated wrist imaging at 3 Tesla (T) MRI. At 3 T MRI, 18 patients (mean age: 36.2 years) with wrist pain and 16 healthy volunteers (mean age: 26.4 years) were examined using 2 D proton density-weighted fat-saturated (PDfs), isotropic 3 D TrueFISP, 3 D MEDIC, and 3 D PDfs SPACE sequences. Image quality was rated on a five-point scale (0 - 4) including overall image quality (OIQ), visibility of important structures (cartilage, ligaments, TFCC) and degree of artifacts. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) of cartilage/bone/muscle/fluid as well as the mean overall SNR/CNR were calculated using region-of-interest analysis. ANOVA, paired t-, and Wilcoxon-signed-rank tests were applied. The image quality of all tested sequences was superior to 3 D PDfs SPACE (p < 0.01). 3 D TrueFISP had the highest combined cartilage score (mean: 3.4) and performed better in cartilage comparisons against 3 D PDfs SPACE in both groups and 2 D PDfs in volunteers (p < 0.05). 3 D MEDIC performed better in 7 of 8 comparisons (p < 0.05) regarding ligaments and TFCC. 2 D PDfs provided constantly high scores. The mean overall SNR/CNR for 2 D PDfs, 3 D PDfs SPACE, 3 D TrueFISP, and 3 D MEDIC were 68/65, 32/27, 45/47, and 57/45, respectively. 2 D PDfs performed best in most SNR/CNR comparisons (p < 0.05) and 3 D MEDIC performed best within the 3 D sequences (p < 0.05). Except 3 D PDfs SPACE, all tested 3 D and 2 D sequences provided high image quality. 3 D TrueFISP was best for cartilage imaging, 3 D MEDIC for ligaments and TFCC and 2 D PDfs for general wrist imaging.

  14. Cd3(MoO4)(TeO3)2: A Polar 3D Compound Containing d10-d0 SCALP-Effect Cations.

    Science.gov (United States)

    Feng, Yuquan; Fan, Huitao; Zhong, Zhiguo; Wang, Hongwei; Qiu, Dongfang

    2016-11-21

    The new polar 3D cadmium molybdotellurite Cd 3 (MoO 4 )(TeO 3 ) 2 was obtained by means of a high-temperature solid-state method. Cd 3 (MoO 4 )(TeO 3 ) 2 is a monoclinic crystal system, and it exhibits the polar space group P2 1 (No. 4). The structure of Cd 3 (MoO 4 )(TeO 3 ) 2 can be viewed as a complicated 3D architecture that is composed of distorted CdO n (n = 6, 7) polyhedra, TeO 3 trigonal pyramids, and MoO 4 polyhedra. The compound features the first 3D NCS cadmium molybdotellurite with 1D 4- and 6-MR channels and a polar structure originating from the TeO 3 groups, MoO 4 groups, and displacements of d 10 Cd 2+ cations. The results were further confirmed by calculations of the net polarization. The UV-vis spectrum and thermal properties indicate that Cd 3 (MoO 4 )(TeO 3 ) 2 exhibits a broad transparent region and excellent thermal stability. SHG tests of Cd 3 (MoO 4 )(TeO 3 ) 2 revealed that its response is approximately the same as that of KH 2 PO 4 at the same grain size between 105 and 150 μm and that it is phase-matchable.

  15. 3D Bayesian contextual classifiers

    DEFF Research Database (Denmark)

    Larsen, Rasmus

    2000-01-01

    We extend a series of multivariate Bayesian 2-D contextual classifiers to 3-D by specifying a simultaneous Gaussian distribution for the feature vectors as well as a prior distribution of the class variables of a pixel and its 6 nearest 3-D neighbours.......We extend a series of multivariate Bayesian 2-D contextual classifiers to 3-D by specifying a simultaneous Gaussian distribution for the feature vectors as well as a prior distribution of the class variables of a pixel and its 6 nearest 3-D neighbours....

  16. 3-D discrete analytical ridgelet transform.

    Science.gov (United States)

    Helbert, David; Carré, Philippe; Andres, Eric

    2006-12-01

    In this paper, we propose an implementation of the 3-D Ridgelet transform: the 3-D discrete analytical Ridgelet transform (3-D DART). This transform uses the Fourier strategy for the computation of the associated 3-D discrete Radon transform. The innovative step is the definition of a discrete 3-D transform with the discrete analytical geometry theory by the construction of 3-D discrete analytical lines in the Fourier domain. We propose two types of 3-D discrete lines: 3-D discrete radial lines going through the origin defined from their orthogonal projections and 3-D planes covered with 2-D discrete line segments. These discrete analytical lines have a parameter called arithmetical thickness, allowing us to define a 3-D DART adapted to a specific application. Indeed, the 3-D DART representation is not orthogonal, It is associated with a flexible redundancy factor. The 3-D DART has a very simple forward/inverse algorithm that provides an exact reconstruction without any iterative method. In order to illustrate the potentiality of this new discrete transform, we apply the 3-D DART and its extension to the Local-DART (with smooth windowing) to the denoising of 3-D image and color video. These experimental results show that the simple thresholding of the 3-D DART coefficients is efficient.

  17. 2D-3D rigid registration to compensate for prostate motion during 3D TRUS-guided biopsy.

    Science.gov (United States)

    De Silva, Tharindu; Fenster, Aaron; Cool, Derek W; Gardi, Lori; Romagnoli, Cesare; Samarabandu, Jagath; Ward, Aaron D

    2013-02-01

    Three-dimensional (3D) transrectal ultrasound (TRUS)-guided systems have been developed to improve targeting accuracy during prostate biopsy. However, prostate motion during the procedure is a potential source of error that can cause target misalignments. The authors present an image-based registration technique to compensate for prostate motion by registering the live two-dimensional (2D) TRUS images acquired during the biopsy procedure to a preacquired 3D TRUS image. The registration must be performed both accurately and quickly in order to be useful during the clinical procedure. The authors implemented an intensity-based 2D-3D rigid registration algorithm optimizing the normalized cross-correlation (NCC) metric using Powell's method. The 2D TRUS images acquired during the procedure prior to biopsy gun firing were registered to the baseline 3D TRUS image acquired at the beginning of the procedure. The accuracy was measured by calculating the target registration error (TRE) using manually identified fiducials within the prostate; these fiducials were used for validation only and were not provided as inputs to the registration algorithm. They also evaluated the accuracy when the registrations were performed continuously throughout the biopsy by acquiring and registering live 2D TRUS images every second. This measured the improvement in accuracy resulting from performing the registration, continuously compensating for motion during the procedure. To further validate the method using a more challenging data set, registrations were performed using 3D TRUS images acquired by intentionally exerting different levels of ultrasound probe pressures in order to measure the performance of our algorithm when the prostate tissue was intentionally deformed. In this data set, biopsy scenarios were simulated by extracting 2D frames from the 3D TRUS images and registering them to the baseline 3D image. A graphics processing unit (GPU)-based implementation was used to improve the

  18. Measurement and Modeling of Ecosystem Risk and Recovery for In Situ Treatment of Contaminated Sediments. Phase 3

    Science.gov (United States)

    2015-08-01

    TITLE AND SUBTITLE Measurement and Modeling of Ecosystem Risk and Recovery for In Sit T t t f C t i t d S di t 5a. CONTRACT NUMBER W912HQ-10-C...Choi was supported in part by a Samsung Scholarship. Collaboration with Newcastle University was facilitated by the Leverhulme Trust, grant FOO 125/AA...and nitrogen deposited on porous alumina 4.2 147.6 Weak Preliminary tests to check the recovery of the selected CCMP from sediment was

  19. The NIH 3D Print Exchange: A Public Resource for Bioscientific and Biomedical 3D Prints.

    Science.gov (United States)

    Coakley, Meghan F; Hurt, Darrell E; Weber, Nick; Mtingwa, Makazi; Fincher, Erin C; Alekseyev, Vsevelod; Chen, David T; Yun, Alvin; Gizaw, Metasebia; Swan, Jeremy; Yoo, Terry S; Huyen, Yentram

    2014-09-01

    The National Institutes of Health (NIH) has launched the NIH 3D Print Exchange, an online portal for discovering and creating bioscientifically relevant 3D models suitable for 3D printing, to provide both researchers and educators with a trusted source to discover accurate and informative models. There are a number of online resources for 3D prints, but there is a paucity of scientific models, and the expertise required to generate and validate such models remains a barrier. The NIH 3D Print Exchange fills this gap by providing novel, web-based tools that empower users with the ability to create ready-to-print 3D files from molecular structure data, microscopy image stacks, and computed tomography scan data. The NIH 3D Print Exchange facilitates open data sharing in a community-driven environment, and also includes various interactive features, as well as information and tutorials on 3D modeling software. As the first government-sponsored website dedicated to 3D printing, the NIH 3D Print Exchange is an important step forward to bringing 3D printing to the mainstream for scientific research and education.

  20. Effect of viewing distance on 3D fatigue caused by viewing mobile 3D content

    Science.gov (United States)

    Mun, Sungchul; Lee, Dong-Su; Park, Min-Chul; Yano, Sumio

    2013-05-01

    With an advent of autostereoscopic display technique and increased needs for smart phones, there has been a significant growth in mobile TV markets. The rapid growth in technical, economical, and social aspects has encouraged 3D TV manufacturers to apply 3D rendering technology to mobile devices so that people have more opportunities to come into contact with many 3D content anytime and anywhere. Even if the mobile 3D technology leads to the current market growth, there is an important thing to consider for consistent development and growth in the display market. To put it briefly, human factors linked to mobile 3D viewing should be taken into consideration before developing mobile 3D technology. Many studies have investigated whether mobile 3D viewing causes undesirable biomedical effects such as motion sickness and visual fatigue, but few have examined main factors adversely affecting human health. Viewing distance is considered one of the main factors to establish optimized viewing environments from a viewer's point of view. Thus, in an effort to determine human-friendly viewing environments, this study aims to investigate the effect of viewing distance on human visual system when exposing to mobile 3D environments. Recording and analyzing brainwaves before and after watching mobile 3D content, we explore how viewing distance affects viewing experience from physiological and psychological perspectives. Results obtained in this study are expected to provide viewing guidelines for viewers, help ensure viewers against undesirable 3D effects, and lead to make gradual progress towards a human-friendly mobile 3D viewing.

  1. From 2D Lithography to 3D Patterning

    NARCIS (Netherlands)

    Van Zeijl, H.W.; Wei, J.; Shen, C.; Verhaar, T.M.; Sarro, P.M.

    2010-01-01

    Lithography as developed for IC device fabrication is a high volume high accuracy patterning technology with strong 2 dimensional (2D) characteristics. This 2D nature makes it a challenge to integrate this technology in a 3 dimensional (3D) manufacturing environment. This article addresses the

  2. RELAP5-3D User Problems

    Energy Technology Data Exchange (ETDEWEB)

    Riemke, Richard Allan

    2002-09-01

    The Reactor Excursion and Leak Analysis Program with 3D capability1 (RELAP5-3D) is a reactor system analysis code that has been developed at the Idaho National Engineering and Environmental Laboratory (INEEL) for the U. S. Department of Energy (DOE). The 3D capability in RELAP5-3D includes 3D hydrodynamics2 and 3D neutron kinetics3,4. Assessment, verification, and validation of the 3D capability in RELAP5-3D is discussed in the literature5,6,7,8,9,10. Additional assessment, verification, and validation of the 3D capability of RELAP5-3D will be presented in other papers in this users seminar. As with any software, user problems occur. User problems usually fall into the categories of input processing failure, code execution failure, restart/renodalization failure, unphysical result, and installation. This presentation will discuss some of the more generic user problems that have been reported on RELAP5-3D as well as their resolution.

  3. 3D for Graphic Designers

    CERN Document Server

    Connell, Ellery

    2011-01-01

    Helping graphic designers expand their 2D skills into the 3D space The trend in graphic design is towards 3D, with the demand for motion graphics, animation, photorealism, and interactivity rapidly increasing. And with the meteoric rise of iPads, smartphones, and other interactive devices, the design landscape is changing faster than ever.2D digital artists who need a quick and efficient way to join this brave new world will want 3D for Graphic Designers. Readers get hands-on basic training in working in the 3D space, including product design, industrial design and visualization, modeling, ani

  4. 3D on-chip microscopy of optically cleared tissue

    Science.gov (United States)

    Zhang, Yibo; Shin, Yoonjung; Sung, Kevin; Yang, Sam; Chen, Harrison; Wang, Hongda; Teng, Da; Rivenson, Yair; Kulkarni, Rajan P.; Ozcan, Aydogan

    2018-02-01

    Traditional pathology relies on tissue biopsy, micro-sectioning, immunohistochemistry and microscopic imaging, which are relatively expensive and labor-intensive, and therefore are less accessible in resource-limited areas. Low-cost tissue clearing techniques, such as the simplified CLARITY method (SCM), are promising to potentially reduce the cost of disease diagnosis by providing 3D imaging and phenotyping of thicker tissue samples with simpler preparation steps. However, the mainstream imaging approach for cleared tissue, fluorescence microscopy, suffers from high-cost, photobleaching and signal fading. As an alternative approach to fluorescence, here we demonstrate 3D imaging of SCMcleared tissue using on-chip holography, which is based on pixel-super-resolution and multi-height phase recovery algorithms to digitally compute the sample's amplitude and phase images at various z-slices/depths through the sample. The tissue clearing procedures and the lens-free imaging system were jointly optimized to find the best illumination wavelength, tissue thickness, staining solution pH, and the number of hologram heights to maximize the imaged tissue volume, minimize the amount of acquired data, while maintaining a high contrast-to-noise ratio for the imaged cells. After this optimization, we achieved 3D imaging of a 200-μm thick cleared mouse brain tissue over a field-of-view of based microscope (20× 0.75NA). Moreover, the lens-free microscope achieves an order-of-magnitude better data efficiency compared to its lens-based counterparts for volumetric imaging of samples. The presented low-cost and high-throughput lens-free tissue imaging technique enabled by CLARITY can be used in various biomedical applications in low-resource-settings.

  5. Defect recovery in proton irradiated Ti-modified stainless steel probed by positron annihilation

    Energy Technology Data Exchange (ETDEWEB)

    Arunkumar, J.; Abhaya, S.; Rajaraman, R.; Amarendra, G. [Materials Science Division, Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamilnadu 603102 (India); Nair, K.G.M. [Materials Science Division, Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamilnadu 603102 (India)], E-mail: kgmn@igcar.gov.in; Sundar, C.S.; Raj, Baldev [Materials Science Division, Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamilnadu 603102 (India)

    2009-02-28

    The defect recovery in proton irradiated Ti-modified D9 steel has been studied by positron annihilation isochronal and isothermal annealing measurements. D9 samples have been irradiated with 3 MeV protons followed by isochronal annealing at various temperatures in the range of 323 to 1273 K. The dramatic decrease in positron annihilation parameters, viz. positron lifetime and Doppler S-parameter, around 500 K indicates the recovery of vacancy-defects. A clear difference in the recovery beyond 700 K is observed between solution annealed and cold worked state of D9 steel due to the precipitation of TiC in the latter. Isothermal annealing studies have been carried out at the temperature wherein vacancies distinctly migrate. Assuming a singly activated process for defect annealing, the effective activation energy for vacancy migration is estimated to be 1.13 {+-} 0.08 eV.

  6. 3D vector flow imaging

    DEFF Research Database (Denmark)

    Pihl, Michael Johannes

    The main purpose of this PhD project is to develop an ultrasonic method for 3D vector flow imaging. The motivation is to advance the field of velocity estimation in ultrasound, which plays an important role in the clinic. The velocity of blood has components in all three spatial dimensions, yet...... are (vx, vy, vz) = (-0.03, 95, 1.0) ± (9, 6, 1) cm/s compared with the expected (0, 96, 0) cm/s. Afterwards, 3D vector flow images from a cross-sectional plane of the vessel are presented. The out of plane velocities exhibit the expected 2D circular-symmetric parabolic shape. The experimental results...... verify that the 3D TO method estimates the complete 3D velocity vectors, and that the method is suitable for 3D vector flow imaging....

  7. RELAP5-3D User Problems

    International Nuclear Information System (INIS)

    Riemke, Richard Allan

    2001-01-01

    The Reactor Excursion and Leak Analysis Program with 3D capability (RELAP5-3D) is a reactor system analysis code that has been developed at the Idaho National Engineering and Environmental Laboratory (INEEL) for the U. S. Department of Energy (DOE). The 3D capability in RELAP5-3D includes 3D hydrodynamics and 3D neutron kinetics. Assessment, verification, and validation of the 3D capability in RELAP5-3D is discussed in the literature. Additional assessment, verification, and validation of the 3D capability of RELAP5-3D will be presented in other papers in this users seminar. As with any software, user problems occur. User problems usually fall into the categories of input processing failure, code execution failure, restart/renodalization failure, unphysical result, and installation. This presentation will discuss some of the more generic user problems that have been reported on RELAP5-3D as well as their resolution

  8. Advanced 3-D Ultrasound Imaging

    DEFF Research Database (Denmark)

    Rasmussen, Morten Fischer

    The main purpose of the PhD project was to develop methods that increase the 3-D ultrasound imaging quality available for the medical personnel in the clinic. Acquiring a 3-D volume gives the medical doctor the freedom to investigate the measured anatomy in any slice desirable after the scan has...... been completed. This allows for precise measurements of organs dimensions and makes the scan more operator independent. Real-time 3-D ultrasound imaging is still not as widespread in use in the clinics as 2-D imaging. A limiting factor has traditionally been the low image quality achievable using...... a channel limited 2-D transducer array and the conventional 3-D beamforming technique, Parallel Beamforming. The first part of the scientific contributions demonstrate that 3-D synthetic aperture imaging achieves a better image quality than the Parallel Beamforming technique. Data were obtained using both...

  9. DELTA 3D PRINTER

    Directory of Open Access Journals (Sweden)

    ȘOVĂILĂ Florin

    2016-07-01

    Full Text Available 3D printing is a very used process in industry, the generic name being “rapid prototyping”. The essential advantage of a 3D printer is that it allows the designers to produce a prototype in a very short time, which is tested and quickly remodeled, considerably reducing the required time to get from the prototype phase to the final product. At the same time, through this technique we can achieve components with very precise forms, complex pieces that, through classical methods, could have been accomplished only in a large amount of time. In this paper, there are presented the stages of a 3D model execution, also the physical achievement after of a Delta 3D printer after the model.

  10. The reliability of magnetic resonance imaging in traumatic brain injury lesion detection

    NARCIS (Netherlands)

    Geurts, B.H.J.; Andriessen, T.M.J.C.; Goraj, B.M.; Vos, P.E.

    2012-01-01

    Objective: This study compares inter-rater-reliability, lesion detection and clinical relevance of T2-weighted imaging (T2WI), Fluid Attenuated Inversion Recovery (FLAIR), T2*-gradient recalled echo (T2*-GRE) and Susceptibility Weighted Imaging (SWI) in Traumatic Brain Injury (TBI). Methods: Three

  11. Investigation of the Correlation Between Neurocognitive Function with Advanced Magnetic Resonance Imaging (MRI), Electroencephalography (EEG) in Patients with Traumatic Brain Injury Exposure: Neurocognitive function and advanced MRI and EEG

    Science.gov (United States)

    2011-01-01

    child (MVA007), pneumonia (MVA017), urinary infection (MVA018), appendix (MVA026), a leg fracture (MVA008), and tonsils and fractures (MVA019). The...Toronto CR 2011-015 59 Glossary ..... DTI – diffusion tensor imaging EEG – electroencephalography FLAIR – fluid-attenuated inversion recovery

  12. Multispectral embedding-based deep neural network for three-dimensional human pose recovery

    Science.gov (United States)

    Yu, Jialin; Sun, Jifeng

    2018-01-01

    Monocular image-based three-dimensional (3-D) human pose recovery aims to retrieve 3-D poses using the corresponding two-dimensional image features. Therefore, the pose recovery performance highly depends on the image representations. We propose a multispectral embedding-based deep neural network (MSEDNN) to automatically obtain the most discriminative features from multiple deep convolutional neural networks and then embed their penultimate fully connected layers into a low-dimensional manifold. This compact manifold can explore not only the optimum output from multiple deep networks but also the complementary properties of them. Furthermore, the distribution of each hierarchy discriminative manifold is sufficiently smooth so that the training process of our MSEDNN can be effectively implemented only using few labeled data. Our proposed network contains a body joint detector and a human pose regressor that are jointly trained. Extensive experiments conducted on four databases show that our proposed MSEDNN can achieve the best recovery performance compared with the state-of-the-art methods.

  13. 3-D Discrete Analytical Ridgelet Transform

    OpenAIRE

    Helbert , David; Carré , Philippe; Andrès , Éric

    2006-01-01

    International audience; In this paper, we propose an implementation of the 3-D Ridgelet transform: the 3-D discrete analytical Ridgelet transform (3-D DART). This transform uses the Fourier strategy for the computation of the associated 3-D discrete Radon transform. The innovative step is the definition of a discrete 3-D transform with the discrete analytical geometry theory by the construction of 3-D discrete analytical lines in the Fourier domain. We propose two types of 3-D discrete lines:...

  14. Tissue content of vitamin D3 and 25-hydroxy vitamin D3 in minipigs after cutaneous synthesis, supplementation and deprivation of vitamin D3

    DEFF Research Database (Denmark)

    Burild, Anders; Frandsen, Henrik Lauritz; Poulsen, Morten

    2015-01-01

    storages of vitamin D3 two studies were carried out in Göttingen minipigs. In study 1 one group of minipigs (n=2) was daily exposed to UV light corresponding to 10–20min of midday sun and another group (n=2) of pigs were fed up to 60μg vitamin D3/day corresponding to 3.7–4.4μg/kg body weight.Study 1......-hydroxy vitamin D3 in serum and skin- and subcutaneous adipose tissue biopsies were repeatedly monitored. Vitamin D3 and 25-hydroxy vitamin D3 were eliminated from the skin and the adipose tissue after UV-exposure was ceased. Supplementation of 13C-vitamin D3 did not seem to affect the decline...... demonstrated that daily UV-exposure of minipigs stimulated the cutaneous synthesis of vitamin D3 and resulted in increasing serum vitamin D3 and 25-hydroxy vitamin D3, but also carcasses containing vitamin D3 and 25-hydroxy vitamin D3. The vitamin D3 content in adipose tissue from the UV-exposed minipigs...

  15. Recovery of uranium from uranium mine waters and copper ore leaching solutions

    Energy Technology Data Exchange (ETDEWEB)

    George, D R; Ross, J R [Salt Lake City Metallurgy Research Center, Salt Lake City, UT (United States)

    1967-06-15

    Waters pumped from uranium mines in New Mexico are processed by ion exchange to recover uranium. Production is approximately 200 lb U{sub 3}O{sub 8}/d from waters containing 5 to 15 ppm U{sub 3}O{sub 8}. Recoveries range from 80 to 90%. Processing plants are described. Uranium has been found in the solutions resulting from the leaching of copper-bearing waste rock at most of the major copper mines in western United States. These solutions, which are processed on a very large scale for recovery of copper, contain 2 to 12 ppm U{sub 3}O{sub 8}. Currently, uranium is not being recovered, but a potential production of up to 6000 lb U{sub 3}O{sub 8}/d is indicated. Ion exchange and solvent extraction research studies are described. (author)

  16. In situ repair of bone and cartilage defects using 3D scanning and 3D printing.

    Science.gov (United States)

    Li, Lan; Yu, Fei; Shi, Jianping; Shen, Sheng; Teng, Huajian; Yang, Jiquan; Wang, Xingsong; Jiang, Qing

    2017-08-25

    Three-dimensional (3D) printing is a rapidly emerging technology that promises to transform tissue engineering into a commercially successful biomedical industry. However, the use of robotic bioprinters alone is not sufficient for disease treatment. This study aimed to report the combined application of 3D scanning and 3D printing for treating bone and cartilage defects. Three different kinds of defect models were created to mimic three orthopedic diseases: large segmental defects of long bones, free-form fracture of femoral condyle, and International Cartilage Repair Society grade IV chondral lesion. Feasibility of in situ 3D bioprinting for these diseases was explored. The 3D digital models of samples with defects and corresponding healthy parts were obtained using high-resolution 3D scanning. The Boolean operation was used to achieve the shape of the defects, and then the target geometries were imported in a 3D bioprinter. Two kinds of photopolymerized hydrogels were synthesized as bioinks. Finally, the defects of bone and cartilage were restored perfectly in situ using 3D bioprinting. The results of this study suggested that 3D scanning and 3D bioprinting could provide another strategy for tissue engineering and regenerative medicine.

  17. 3-D magnetic field calculations for wiggglers using MAGNUS-3D

    International Nuclear Information System (INIS)

    Pissanetzky, S.; Tompkins, P.

    1988-01-01

    The recent but steady trend toward increased magnetic and geometric complexity in the design of wigglers and undulators, of which tapered wigglers, hybrid structures, laced electromagnetic wigglers, magnetic cladding, twisters and magic structures are examples, has caused a need for reliable 3-D computer models and a better understanding of the behavior of magnetic systems in three dimensions. The capabilities of the MAGNUS-3D Group of Programs are ideally suited to solve this class of problems and provide insight into 3-D effects. MAGNUS-3D can solve any problem of Magnetostatics involving permanent magnets, linear or nonlinear ferromagnetic materials and electric conductors of any shape in space. The magnetic properties of permanent magnets are described by the complete nonlinear demagnetization curve as provided by the manufacturer, or, at the user's choice, by a simpler approximation involving the coercive force, the residual induction and the direction of magnetization. The ferromagnetic materials are described by a magnetization table and an accurate interpolation relation. An internal library with properties of common industrial steels is available. The conductors are independent of the mesh and are described in terms of conductor elements from an internal library

  18. Learning how to recover from job stress: effects of a recovery training program on recovery, recovery-related self-efficacy, and well-being.

    Science.gov (United States)

    Hahn, Verena C; Binnewies, Carmen; Sonnentag, Sabine; Mojza, Eva J

    2011-04-01

    This quasi-experimental study evaluated the effects of a recovery training program on recovery experiences (psychological detachment from work, relaxation, mastery experiences, and control during off-job time), recovery-related self-efficacy, and well-being outcomes. The training comprised two sessions held one week apart. Recovery experiences, recovery-related self-efficacy, and well-being outcomes were measured before the training (T1) and one week (T2) and three weeks (T3) after the training. A training group consisting of 48 individuals and a waitlist control group of 47 individuals were compared (N = 95). Analyses of covariance revealed an increase in recovery experiences at T2 and T3 (for mastery only at T2). Recovery-related self-efficacy and sleep quality increased at T2 and T3, perceived stress and state negative affect decreased at T3. No training effects were found for emotional exhaustion.

  19. Nuclear Fuel Recovery and Recycling Center. License application, PSAR, volume 3

    International Nuclear Information System (INIS)

    1976-01-01

    Volume 3 comprises Chapter 5 which provides descriptive information on Nuclear Fuel Recovery and Recycling Center buildings and other facilities, including their locations. The design features discussed include those used to withstand environmental and accidental forces and to insure radiological protection

  20. Recovery of α-Al{sub 2}O{sub 3} from ionizing radiation dosimetric sensors

    Energy Technology Data Exchange (ETDEWEB)

    Sanches, Edgar Aparecido, E-mail: sanches.ufam@gmail.com [Universidade Federal do Amazonas (UFAM), Manaus, AM (Brazil). Dept. de Fisica; Costalonga, Ademir Geraldo Cavallari; Mascarenhas, Yvonne Primerano [Universidade de Sao Paulo (IFSC/USP), Sao Carlos, SP (Brazil). Institute de Fisica; Nascimento, Luana de Freitas [Belgium Nuclear Research Centre, SCK-CEN, Mol (Belgium); Mascarenhas, Yvone Maria [SAPRA S/A Servico de Assessoria e Protecao Radiologica, Sao Carlos, SP, (Brazil)

    2015-01-15

    Corundum, sapphire or α-Al{sub 2}O{sub 3} is an important technological material in many optical and electronic applications such as solid-state lasers, optical windows and, more recently, as a radiation detector. Landauer (Glenwood, IL, USA) accumulated large number of archived and stored Luxel™ dosemeters composed of Al{sub 2}O{sub 3}:C, which were subjected to a recovery process. Due to the importance of this advanced crystalline material in OSL dosimetry, a recovery process was developed based on the dosemeters calcination and Al{sub 2}O{sub 3}:C has been reused in manufacturing of new dosemeters. This paper does not aim to optimize the recovery process, but provides an opportunity to study the involved process parameters and to recover this valuable crystalline material from used dosemeters. To the best of our knowledge no other recovery process involving this dosimetric material was described in scientific literature. Fourier Transform Infrared Spectrometry (FTIR), Thermogravimetry/Differential Thermoanalysis (TG/DTA), Differential Scanning Calorimetry (DSC), X-ray Diffraction (XRD), Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES), Optically Stimulated Luminescence (OSL) and Rietveld Refinement were used to characterize the recovered material and to check for the stability of its structural and dosimetric properties. (author)

  1. AxiSEM3D: broadband seismic wavefields in 3-D aspherical Earth models

    Science.gov (United States)

    Leng, K.; Nissen-Meyer, T.; Zad, K. H.; van Driel, M.; Al-Attar, D.

    2017-12-01

    Seismology is the primary tool for data-informed inference of Earth structure and dynamics. Simulating seismic wave propagation at a global scale is fundamental to seismology, but remains as one of most challenging problems in scientific computing, because of both the multiscale nature of Earth's interior and the observable frequency band of seismic data. We present a novel numerical method to simulate global seismic wave propagation in realistic 3-D Earth models. Our method, named AxiSEM3D, is a hybrid of spectral element method and pseudospectral method. It reduces the azimuthal dimension of wavefields by means of a global Fourier series parameterization, of which the number of terms can be locally adapted to the inherent azimuthal smoothness of the wavefields. AxiSEM3D allows not only for material heterogeneities, such as velocity, density, anisotropy and attenuation, but also for finite undulations on radial discontinuities, both solid-solid and solid-fluid, and thereby a variety of aspherical Earth features such as ellipticity, topography, variable crustal thickness, and core-mantle boundary topography. Such interface undulations are equivalently interpreted as material perturbations of the contiguous media, based on the "particle relabelling transformation". Efficiency comparisons show that AxiSEM3D can be 1 to 3 orders of magnitude faster than conventional 3-D methods, with the speedup increasing with simulation frequency and decreasing with model complexity, but for all realistic structures the speedup remains at least one order of magnitude. The observable frequency range of global seismic data (up to 1 Hz) has been covered for wavefield modelling upon a 3-D Earth model with reasonable computing resources. We show an application of surface wave modelling within a state-of-the-art global crustal model (Crust1.0), with the synthetics compared to real data. The high-performance C++ code is released at github.com/AxiSEM3D/AxiSEM3D.

  2. 3D PHOTOGRAPHS IN CULTURAL HERITAGE

    Directory of Open Access Journals (Sweden)

    W. Schuhr

    2013-07-01

    Full Text Available This paper on providing "oo-information" (= objective object-information on cultural monuments and sites, based on 3D photographs is also a contribution of CIPA task group 3 to the 2013 CIPA Symposium in Strasbourg. To stimulate the interest in 3D photography for scientists as well as for amateurs, 3D-Masterpieces are presented. Exemplary it is shown, due to their high documentary value ("near reality", 3D photography support, e.g. the recording, the visualization, the interpretation, the preservation and the restoration of architectural and archaeological objects. This also includes samples for excavation documentation, 3D coordinate calculation, 3D photographs applied for virtual museum purposes and as educational tools. In addition 3D photography is used for virtual museum purposes, as well as an educational tool and for spatial structure enhancement, which in particular holds for inscriptions and in rock arts. This paper is also an invitation to participate in a systematic survey on existing international archives of 3D photographs. In this respect it is also reported on first results, to define an optimum digitization rate for analog stereo views. It is more than overdue, in addition to the access to international archives for 3D photography, the available 3D photography data should appear in a global GIS(cloud-system, like on, e.g., google earth. This contribution also deals with exposing new 3D photographs to document monuments of importance for Cultural Heritage, including the use of 3D and single lense cameras from a 10m telescope staff, to be used for extremely low earth based airborne 3D photography, as well as for "underwater staff photography". In addition it is reported on the use of captive balloon and drone platforms for 3D photography in Cultural Heritage. It is liked to emphasize, the still underestimated 3D effect on real objects even allows, e.g., the spatial perception of extremely small scratches as well as of nuances in

  3. Use of 3D reconstruction cloacagrams and 3D printing in cloacal malformations.

    Science.gov (United States)

    Ahn, Jennifer J; Shnorhavorian, Margarett; Amies Oelschlager, Anne-Marie E; Ripley, Beth; Shivaram, Giridhar M; Avansino, Jeffrey R; Merguerian, Paul A

    2017-08-01

    Cloacal anomalies are complex to manage, and the anatomy affects prognosis and management. Assessment historically includes examination under anesthesia, and genitography is often performed, but these do not consistently capture three-dimensional (3D) detail or spatial relationships of the anatomic structures. Three-dimensional reconstruction cloacagrams can provide a high level of detail including channel measurements and the level of the cloaca (3 cm), which typically determines the approach for surgical reconstruction and can impact long-term prognosis. Yet this imaging modality has not yet been directly compared with intra-operative or endoscopic findings. Our objective was to compare 3D reconstruction cloacagrams with endoscopic and intraoperative findings, as well as to describe the use of 3D printing to create models for surgical planning and education. An IRB-approved retrospective review of all cloaca patients seen by our multi-disciplinary program from 2014 to 2016 was performed. All patients underwent examination under anesthesia, endoscopy, 3D reconstruction cloacagram, and subsequent reconstructive surgery at a later date. Patient characteristics, intraoperative details, and measurements from endoscopy and cloacagram were reviewed and compared. One of the 3D cloacagrams was reformatted for 3D printing to create a model for surgical planning. Four patients were included for review, with the Figure illustrating 3D cloacagram results. Measurements of common channel length and urethral length were similar between modalities, particularly with confirming the level of cloaca. No patient experienced any complications or adverse effects from cloacagram or endoscopy. A model was successfully created from cloacagram images with the use of 3D printing technology. Accurate preoperative assessment for cloacal anomalies is important for counseling and surgical planning. Three-dimensional cloacagrams have been shown to yield a high level of anatomic detail. Here

  4. 3D+time acquisitions of 3D cell culture by means of lens-free tomographic microscopy

    Science.gov (United States)

    Berdeu, Anthony; Laperrousaz, Bastien; Bordy, Thomas; Morales, S.; Gidrol, Xavier; Picollet-D'hahan, Nathalie; Allier, Cédric

    2018-02-01

    We propose a three-dimensional (3D) imaging platform based on lens-free microscopy to perform multi-angle acquisitions on 3D cell cultures embedded in extracellular matrix (ECM). We developed algorithms based on the Fourier diffraction theorem to perform fully 3D reconstructions of biological samples and we adapted the lens-free microscope to incubator conditions. Here we demonstrate for the first time, 3D+time lens-free acquisitions of 3D cell culture over 8 days directly into the incubator. The 3D reconstructed volume is as large as 5 mm3 and provides a unique way to observe in the same 3D cell culture experiment multiple cell migration strategies. Namely, in a 3D cell culture of prostate epithelial cells embedded within a Matrigel® matrix, we are able to distinguish single cell 'leaders', migration of cell clusters, migration of large aggregates of cells, and also close-gap and large-scale branching. In addition, we observe long-scale 3D deformations of the ECM that modify the geometry of the 3D cell culture. Interestingly, we also observed the opposite, i.e. we found that large aggregates of cells may deform the ECM by generating traction forces over very long distances. In sum we put forward a novel 3D lens-free microscopy tomographic technique to study the single and collective cell migrations, the cell-to-cell interactions and the cell-to-matrix interactions.

  5. Applications of 2D to 3D conversion for educational purposes

    Science.gov (United States)

    Koido, Yoshihisa; Morikawa, Hiroyuki; Shiraishi, Saki; Takeuchi, Soya; Maruyama, Wataru; Nakagori, Toshio; Hirakata, Masataka; Shinkai, Hirohisa; Kawai, Takashi

    2013-03-01

    There are three main approaches creating stereoscopic S3D content: stereo filming using two cameras, stereo rendering of 3D computer graphics, and 2D to S3D conversion by adding binocular information to 2D material images. Although manual "off-line" conversion can control the amount of parallax flexibly, 2D material images are converted according to monocular information in most cases, and the flexibility of 2D to S3D conversion has not been exploited. If the depth is expressed flexibly, comprehensions and interests from converted S3D contents are anticipated to be differed from those from 2D. Therefore, in this study we created new S3D content for education by applying 2D to S3D conversion. For surgical education, we created S3D surgical operation content under a surgeon using a partial 2D to S3D conversion technique which was expected to concentrate viewers' attention on significant areas. And for art education, we converted Ukiyoe prints; traditional Japanese artworks made from a woodcut. The conversion of this content, which has little depth information, into S3D, is expected to produce different cognitive processes from those evoked by 2D content, e.g., the excitation of interest, and the understanding of spatial information. In addition, the effects of the representation of these contents were investigated.

  6. Underwater 3D filming

    OpenAIRE

    Rinaldi, Roberto

    2014-01-01

    After an experimental phase of many years, 3D filming is now effective and successful. Improvements are still possible, but the film industry achieved memorable success on 3D movie’s box offices due to the overall quality of its products. Special environments such as space (“Gravity” ) and the underwater realm look perfect to be reproduced in 3D. “Filming in space” was possible in “Gravity” using special effects and computer graphic. The underwater realm is still difficult to be handled. Unde...

  7. Relative effectiveness of oral 25-hydroxyvitamin D3 and vitamin D3 in raising wintertime serum 25-hydroxyvitamin D in older adults.

    Science.gov (United States)

    Cashman, Kevin D; Seamans, Kelly M; Lucey, Alice J; Stöcklin, Elisabeth; Weber, Peter; Kiely, Mairead; Hill, Tom R

    2012-06-01

    The relative potency of 25-hydroxyvitamin D3 to vitamin D3 needs to be better defined so that food-composition tables can better reflect the true vitamin D nutritive value of certain foods. We performed a randomized, controlled intervention study in apparently healthy, free-living adults to investigate whether the intake of 25-hydroxyvitamin D3 is 5 times more potent in raising serum 25-hydroxyvitamin D [25(OH)D] during winter compared with an equivalent amount of vitamin D3. A randomized, placebo-controlled, double-blind intervention study was conducted in adults aged ≥50 y (n = 56) who consumed a placebo, 20 μg vitamin D3, or 7 or 20 μg 25-hydroxyvitamin D3 daily throughout 10 wk of winter. Serum 25(OH)D was measured by using an enzyme-linked immunoassay, and serum albumin-corrected calcium (S-Ca) was assessed colorimetrically at the baseline, midpoint, and endpoint of the study. The mean (±SD) increases (per microgram of vitamin D compound) in serum 25(OH)D concentrations over baseline after 10 wk of supplementation were 0.96 ± 0.62, 4.02 ± 1.27, and 4.77 ± 1.04 nmol · L(-1) · μg intake(-1) for the 20-μg vitamin D3/d and 7- and 20-μg 25-hydroxyvitamin D3/d groups, respectively. A comparison of the 7- and 20-μg 25-hydroxyvitamin D3/d groups with the 20-μg vitamin D3/d group yielded conversion factors of 4.2 and 5, respectively. There was no effect of treatment on S-Ca concentrations and no incidence of hypercalcemia (S-Ca >2.6 nmol/L). Each microgram of orally consumed 25-hydroxyvitamin D3 was about 5 times more effective in raising serum 25(OH)D in older adults in winter than an equivalent amount of vitamin D3. This conversion factor could be used in food-compositional tables for relevant foods. This study was registered at clinicaltrials.gov as NCT01398202.

  8. Abusir 3D survey 2015

    Directory of Open Access Journals (Sweden)

    Yukinori Kawae

    2016-12-01

    Full Text Available In 2015, in collaboration with the Czech Institute of Egyptology, we, a Japanese consortium, initiated the Abusir 3D Survey (A-3DS for the 3D documentation of the site’s pyramids, which have not been updated since the time of the architectural investigations of Vito Maragioglio and Celeste Rinaldi in the 1960s to the 1970s. The first season of our project focused on the exterior of Neferirkare’s pyramid, the largest pyramid at Abusir. By developing a strategic mathematical 3D survey plan, step-by-step 3D documentation to suit specific archaeological needs, and producing a new display method for the 3D data, we successfully measured the dimensions of the pyramid in a cost-effective way.

  9. DYNA3D2000*, Explicit 3-D Hydrodynamic FEM Program

    International Nuclear Information System (INIS)

    Lin, J.

    2002-01-01

    1 - Description of program or function: DYNA3D2000 is a nonlinear explicit finite element code for analyzing 3-D structures and solid continuum. The code is vectorized and available on several computer platforms. The element library includes continuum, shell, beam, truss and spring/damper elements to allow maximum flexibility in modeling physical problems. Many materials are available to represent a wide range of material behavior, including elasticity, plasticity, composites, thermal effects and rate dependence. In addition, DYNA3D has a sophisticated contact interface capability, including frictional sliding, single surface contact and automatic contact generation. 2 - Method of solution: Discretization of a continuous model transforms partial differential equations into algebraic equations. A numerical solution is then obtained by solving these algebraic equations through a direct time marching scheme. 3 - Restrictions on the complexity of the problem: Recent software improvements have eliminated most of the user identified limitations with dynamic memory allocation and a very large format description that has pushed potential problem sizes beyond the reach of most users. The dominant restrictions remain in code execution speed and robustness, which the developers constantly strive to improve

  10. Analysis of the 3d9ns (n = 5, 6), 3d95p, 3d94f and 3d84s4p configurations of five times ionized arsenic (As VI)

    International Nuclear Information System (INIS)

    Ryabtsev, A.N.; Gayasov, R.R.; Joshi, Y.N.; Van het Hof, G.J.

    1993-01-01

    The spectrum of arsenic was photographed in the 100-1250 A region on grazing and normal incidence spectrographs. The spectrum of As VI was extended. Seven out of eight levels of the 3d 9 5s and 6s configurations, 12 out of 12 levels of the 3d 9 5p configuration, 13 out of 20 levels of the 3d 9 4f configuration and 35 levels belonging to the 3d 9 4s4p configuration have been established. Least-Square-Fitted parametric calculations involving configuration interactions both in even and odd parity systems were carried out to adequately interpret the spectrum. One hundred and thirty-two additional lines were classified in the As VI spectrum. A new value of the ionization limit was obtained. Thus, the 3d 9 2 D 5/2 ground level in As VII lies 977500 cm -1 (121.17 eV) above the As VI ground state. (orig.)

  11. Recovery from acidification in European surface waters

    Czech Academy of Sciences Publication Activity Database

    Evans, C. D.; Cullen, J. M.; Alewell, C.; Kopáček, Jiří; Marchetto, A.; Moldan, F.; Prechtel, A.; Rogora, M.; Veselý, J.; Wright, R.

    2001-01-01

    Roč. 5, č. 3 (2001), s. 283-297 ISSN 1027-5606 R&D Projects: GA ČR GA206/00/0063 Grant - others:CEC RECOVER(XE) 2010 EVK1-CT-1999-00018; GMER(DE) PT BEO 51-0339476; UKDETR(GB) EPG1/3/92; NNP(NO) SFT2000; CEC(XE) EMERGE EVK1-CT-1999-00032 Keywords : acidification * recovery * sulphate Subject RIV: DJ - Water Pollution ; Quality Impact factor: 1.127, year: 2001

  12. Potencies of vitamin D analogs, 1α-hydroxyvitamin D3 , 1α-hydroxyvitamin D2 and 25-hydroxyvitamin D3 , in lowering cholesterol in hypercholesterolemic mice in vivo.

    Science.gov (United States)

    Quach, Holly P; Dzekic, Tamara; Bukuroshi, Paola; Pang, K Sandy

    2018-04-01

    Vitamin D 3 and the synthetic vitamin D analogs, 1α-hydroxyvitamin D 3 [1α(OH)D 3 ], 1α-hydroxyvitamin D 2 [1α(OH)D 2 ] and 25-hydroxyvitamin D 3 [25(OH)D 3 ] were appraised for their vitamin D receptor (VDR) associated-potencies as cholesterol lowering agents in mice in vivo. These precursors are activated in vivo: 1α(OH)D 3 and 1α(OH)D 2 are transformed by liver CYP2R1 and CYP27A1 to active VDR ligands, 1α,25-dihydroxyvitamin D 3 [1,25(OH) 2 D 3 ] and 1α,25-dihydroxyvitamin D 2 [1,25(OH) 2 D 2 ] , respectively. 1α(OH)D 2 may also be activated by CYP24A1 to 1α,24-dihydroxyvitamin D 2 [1,24(OH) 2 D 2 ], another active VDR ligand. 25(OH)D 3 , the metabolite formed via CYP2R1 and or CYP27A1 in liver from vitamin D 3 , is activated by CYP27B1 in the kidney to 1,25(OH) 2 D 3 . In C57BL/6 mice fed the high fat/high cholesterol Western diet for 3 weeks, vitamin D analogs were administered every other day intraperitoneally during the last week of the diet. The rank order for cholesterol lowering, achieved via mouse liver small heterodimer partner (Shp) inhibition and increased cholesterol 7α-hydroxylase (Cyp7a1) expression, was: 1.75 nmol/kg 1α(OH)D 3  > 1248 nmol/kg 25(OH)D 3 (dose ratio of 0.0014) > > 1625 nmol/kg vitamin D 3 . Except for 1.21 nmol/kg 1α(OH)D 2 that failed to lower liver and plasma cholesterol contents, a significant negative correlation was observed between the liver concentration of 1,25(OH) 2 D 3 formed from the precursors and liver cholesterol levels. The composite results show that vitamin D analogs 1α(OH)D 3 and 25(OH)D 3 exhibit cholesterol lowering properties upon activation to 1,25(OH) 2 D 3 : 1α(OH)D 3 is rapidly activated by liver enzymes and 25(OH)D 3 is slowly activated by renal Cyp27b1 in mouse. Copyright © 2018 John Wiley & Sons, Ltd.

  13. A simple automated solid-phase extraction procedure for measurement of 25-hydroxyvitamin D3 and D2 by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Knox, Susan; Harris, John; Calton, Lisa; Wallace, A Michael

    2009-05-01

    Measurement of 25-hydroxyvitamin D(3) (25OHD(3)) and D(2) (25OHD(2)) is challenging. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods have been described but they are often complex and difficult to automate. We have developed a simplified procedure involving an automated solid-phase extraction (SPE). Internal standard (hexadeuterated 25-hydroxyvitamin D(3)) was added to serum or plasma followed by protein precipitation with methanol. Following centrifugation, a robotic instrument (CTC PAL [Presearch] for ITSP SPE [MicroLiter Analytical Supplies, Inc]) performed a six-step SPE procedure and the purified samples were injected into the LC-MS/MS. Quantification of 25OHD(3) and 25OHD(2) was by electrospray ionization MS/MS in the multiple-reaction monitoring mode. The lower limit of quantitation was 4.0 nmol/L for 25OHD(3) and 7.5 nmol/L for 25OHD(2). Within- and between-assay precision was below 10% over the concentration range of 22.5-120 nmol/L for D(3) and 17.5-70 nmol/L for D(2) (n = 10). The calibration was linear up to 2500 nmol/L (r = 0.99). Recoveries ranged between 89% and 104% for both metabolites and no ion suppression was observed. The results obtained compared well (r = 0.96) with the IDS-OCTEIA 25-hydroxyvitamin D enzyme immunoassay for samples containing less than 125 nmol/L, at higher concentrations the immunodiagnostic system (IDS) method showed positive bias. Our simplified sample preparation and automated SPE method is suitable for the measurement of 25OHD(3) and D(2) in a routine laboratory environment. The system can process up to 300 samples per day with no cumbersome solvent evaporation step and minimal operator intervention.

  14. A 3D Printing Model Watermarking Algorithm Based on 3D Slicing and Feature Points

    Directory of Open Access Journals (Sweden)

    Giao N. Pham

    2018-02-01

    Full Text Available With the increase of three-dimensional (3D printing applications in many areas of life, a large amount of 3D printing data is copied, shared, and used several times without any permission from the original providers. Therefore, copyright protection and ownership identification for 3D printing data in communications or commercial transactions are practical issues. This paper presents a novel watermarking algorithm for 3D printing models based on embedding watermark data into the feature points of a 3D printing model. Feature points are determined and computed by the 3D slicing process along the Z axis of a 3D printing model. The watermark data is embedded into a feature point of a 3D printing model by changing the vector length of the feature point in OXY space based on the reference length. The x and y coordinates of the feature point will be then changed according to the changed vector length that has been embedded with a watermark. Experimental results verified that the proposed algorithm is invisible and robust to geometric attacks, such as rotation, scaling, and translation. The proposed algorithm provides a better method than the conventional works, and the accuracy of the proposed algorithm is much higher than previous methods.

  15. Characteristics of injury and recovery of net NO3- transport of barley seedlings from treatments of NaCl

    Science.gov (United States)

    Klobus, G.; Ward, M. R.; Huffaker, R. C.

    1988-01-01

    The nature of the injury and recovery of nitrate uptake (net uptake) from NaCl stress in young barley (Hordeum vulgare L, var CM 72) seedlings was investigated. Nitrate uptake was inhibited rapidly by NaCl, within 1 minute after exposure to 200 millimolar NaCl. The duration of exposure to saline conditions determined the time of recovery of NO3- uptake from NaCl stress. Recovery was dependent on the presence of NO3- and was inhibited by cycloheximide, 6-methylpurine, and cerulenin, respective inhibitors of protein, RNA, and sterol/fatty acid synthesis. These inhibitors also prevented the induction of the NO3- uptake system in uninduced seedlings. Uninduced seedlings exhibited endogenous NO3- transport activity that appeared to be constitutive. This constitutive activity was also inhibited by NaCl. Recovery of constitutive NO3- uptake did not require the presence of NO3-.

  16. ABI3 mediates dehydration stress recovery response in Arabidopsis thaliana by regulating expression of downstream genes.

    Science.gov (United States)

    Bedi, Sonia; Sengupta, Sourabh; Ray, Anagh; Nag Chaudhuri, Ronita

    2016-09-01

    ABI3, originally discovered as a seed-specific transcription factor is now implicated to act beyond seed physiology, especially during abiotic stress. In non-seed plants, ABI3 is known to act in desiccation stress signaling. Here we show that ABI3 plays a role in dehydration stress response in Arabidopsis. ABI3 gene was upregulated during dehydration stress and its expression was maintained during subsequent stress recovery phases. Comparative gene expression studies in response to dehydration stress and stress recovery were done with genes which had potential ABI3 binding sites in their upstream regulatory regions. Such studies showed that several genes including known seed-specific factors like CRUCIFERIN1, CRUCIFERIN3 and LEA-group of genes like LEA76, LEA6, DEHYDRIN LEA and LEA-LIKE got upregulated in an ABI3-dependent manner, especially during the stress recovery phase. ABI3 got recruited to regions upstream to the transcription start site of these genes during dehydration stress response through direct or indirect DNA binding. Interestingly, ABI3 also binds to its own promoter region during such stress signaling. Nucleosomes covering potential ABI3 binding sites in the upstream sequences of the above-mentioned genes alter positions, and show increased H3 K9 acetylation during stress-induced transcription. ABI3 thus mediates dehydration stress signaling in Arabidopsis through regulation of a group of genes that play a role primarily during stress recovery phase. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. The analysis of the 3d8, 3d74p and 3p53d9 configurations of Se IX

    International Nuclear Information System (INIS)

    Kleef, T.A.M. van; Uylings, P.; Joshi, Y.N.; Podobedova, L.I.; Ryabtsev, A.N.

    1984-01-01

    The ninth spectrum of selenium (Se IX) was photographed in the region 100-140 A on a variety of grazing incidence spectrographs using a triggered spark or an open spark as sources. On the basis of these measurements all levels of the 3d 8 configuration, 11 out of 12 levels of the 3p 5 3d 9 configuration and 95 out of 110 levels of the 3d 7 4p configuration have been established. A strong configuration interaction exists between the two odd configurations. Least-squares-fit and Hartree-Fock parameter calculations support the analysis. Two hundred and twenty-five (225) lines have been classified in Se IX. (orig.)

  18. Tracking studies in eRHIC energy-recovery recirculator

    Energy Technology Data Exchange (ETDEWEB)

    Meot, F. [Brookhaven National Lab. (BNL), Upton, NY (United States); Brooks, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ptitsyn, V. [Brookhaven National Lab. (BNL), Upton, NY (United States); Trbojevic, D. [Brookhaven National Lab. (BNL), Upton, NY (United States); Tsoupas, N. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-07-13

    Beam and polarization tracking studies in eRHIC energy recovery electron recirculator are presented, based on a very preliminary design of the FFAG lattice. These simulations provide examples of some of the beam and spin optics aspects of the linear FFAG lattice concept and its application in eRHIC, they provide code benchmarking for synchrotron radiation and spin diffusion in addition, and pave the way towards end-to-end 6-D(phasespace)+3D(spin) tracking simulations.

  19. Recovery of Waterflood Residual Oil Using Alkali, Surfactant and Polymer Slugs in Radial Cores Récupération d'huile résiduelle par injection d'eau améliorée de produits alcalins, de tensio-actifs et de polymères dans des carottes radiales

    Directory of Open Access Journals (Sweden)

    Nasr-El-Din H. A.

    2006-11-01

    Full Text Available An experimental study has been conducted to examine mobilization and recovery of waterflood residual oil in radial cores. Alkali, surfactant, and polymer slugs of various compositions, sizes and sequences were tested. Core flood experiments were conducted with unfired radial Berea sandstone disks at a flow rate of 8 cm3/h. David Lloydminster crude oil (total acid number of 0. 45 mg KOH/g oil was used. The results of the present work showed that the composition and sequence of the injected chemical slug play an important role in mobilization and recovery of residual oil. For slugs lacking either mobility control, or low interfacial tension, no oil bank was formed and tertiary oil recovery was less than 20% Sor. A significant oil bank and tertiary oil recovery up to 70 % Sor were obtained with slugs having mobility control and low interfacial tension. However, maximum oil cut, incre-mental oil recovery and surfactant propagation were found to be functions of the alkali content in the slug. The incremental oil recovery, oil cut and slug injectivity greatly improved as the alkali concentration (sodium carbonate in the combined slug was increased. A slight delay in surfactant breakthrough and a significantly slower rate of surfactant propagation were observed at higher sodium carbonate concentrations. Une étude expérimentale ayant pour but d'examiner la mobilisation et la récupération assistée d'huile résiduelle, à la suite d'un déplacement par l'eau en milieu poreux, a été conduite. Des bouchons de produit alcalin, de surfactant et de polymère, ayant des compositions, grosseurs et séquences d'injection variées, furent essayés. Les déplacements en milieu poreux furent conduits en utilisant des carottes de grès berea (non traités à haute température et un débit de 8,0 cm3/h. Pour ce faire, on utilisa de l'huile de David Lloydminster (ayant un nombre acide de 0,45 mg KOH/g d'huile. Les résultats de ce travail ont démontré que la

  20. Computationally efficient storage of 3D particle intensity and position data for use in 3D PIV and 3D PTV

    International Nuclear Information System (INIS)

    Atkinson, C; Buchmann, N A; Soria, J

    2013-01-01

    Three-dimensional (3D) volumetric velocity measurement techniques, such as tomographic or holographic particle image velocimetry (PIV), rely upon the computationally intensive formation, storage and localized interrogation of multiple 3D particle intensity fields. Calculation of a single velocity field typically requires the extraction of particle intensities into tens of thousands of 3D sub-volumes or discrete particle clusters, the processing of which can significantly affect the performance of 3D cross-correlation based PIV and 3D particle tracking velocimetry (PTV). In this paper, a series of popular and customized volumetric data formats are presented and investigated using synthetic particle volumes and experimental data arising from tomographic PIV measurements of a turbulent boundary layer. Results show that the use of a sub-grid ordered non-zero intensity format with a sub-grid size of 16 × 16 × 16 points provides the best performance for cross-correlation based PIV analysis, while a particle clustered non-zero intensity format provides the best format for PTV applications. In practical tomographic PIV measurements the sub-grid ordered non-zero intensity format offered a 29% improvement in reconstruction times, while providing a 93% reduction in volume data requirements and a 28% overall improvement in cross-correlation based velocity analysis and validation times. (paper)

  1. Waste Heat Recovery. Technology and Opportunities in U.S. Industry

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Ilona [BCS, Inc., Laurel, MD (United States); Choate, William T. [BCS, Inc., Laurel, MD (United States); Davidson, Amber [BCS, Inc., Laurel, MD (United States)

    2008-03-01

    This study was initiated in order to evaluate RD&D needs for improving waste heat recovery technologies. A bottomup approach is used to evaluate waste heat quantity, quality, recovery practices, and technology barriers in some of the largest energyconsuming units in U.S. manufacturing. The results from this investigation serve as a basis for understanding the state of waste heat recovery and providing recommendations for RD&D to advance waste heat recovery technologies.

  2. 3D shape detection of the indoor space based on 3D-Hough method

    OpenAIRE

    安齋, 達也; ANZAI, Tatsuya

    2013-01-01

    This paper describes methods for detecting the 3D shapes of the indoor space that is represented as a combination of planes such as a wall, desk, or whatnot. Detecting the planes makes it possible to perform calibration of multiple sensors and 3D mapping, and then produces various services such as the acquisition of life logs, AR interaction, and invader detection. This paper proposes and verifies three algorithms. First, it mentions a way to use2D-Hough.The proposed technique converts 3D dat...

  3. Hybrid 3D printing and electrodeposition approach for controllable 3D alginate hydrogel formation.

    Science.gov (United States)

    Shang, Wanfeng; Liu, Yanting; Wan, Wenfeng; Hu, Chengzhi; Liu, Zeyang; Wong, Chin To; Fukuda, Toshio; Shen, Yajing

    2017-06-07

    Calcium alginate hydrogels are widely used as biocompatible materials in a substantial number of biomedical applications. This paper reports on a hybrid 3D printing and electrodeposition approach for forming 3D calcium alginate hydrogels in a controllable manner. Firstly, a specific 3D hydrogel printing system is developed by integrating a customized ejection syringe with a conventional 3D printer. Then, a mixed solution of sodium alginate and CaCO 3 nanoparticles is filled into the syringe and can be continuously ejected out of the syringe nozzle onto a conductive substrate. When applying a DC voltage (∼5 V) between the substrate (anode) and the nozzle (cathode), the Ca 2+ released from the CaCO 3 particles can crosslink the alginate to form calcium alginate hydrogel on the substrate. To elucidate the gel formation mechanism and better control the gel growth, we can further establish and verify a gel growth model by considering several key parameters, i.e., applied voltage and deposition time. The experimental results indicate that the alginate hydrogel of various 3D structures can be formed by controlling the movement of the 3D printer. A cell viability test is conducted and shows that the encapsulated cells in the gel can maintain a high survival rate (∼99% right after gel formation). This research establishes a reliable method for the controllable formation of 3D calcium alginate hydrogel, exhibiting great potential for use in basic biology and applied biomedical engineering.

  4. 3D virtuel udstilling

    DEFF Research Database (Denmark)

    Tournay, Bruno; Rüdiger, Bjarne

    2006-01-01

    3d digital model af Arkitektskolens gård med virtuel udstilling af afgangsprojekter fra afgangen sommer 2006. 10 s.......3d digital model af Arkitektskolens gård med virtuel udstilling af afgangsprojekter fra afgangen sommer 2006. 10 s....

  5. The 3-dimensional core model DYN3D

    Energy Technology Data Exchange (ETDEWEB)

    Grundmann, U.; Mittag, S.; Rohde, U.

    1999-01-01

    Analyzing the safety margins in transients and accidents of nuclear reactors 3-dimensional models of the core were used to avoid conservative assumptions needed for point kinetics or 1-dimensional models. Therefore, the 3D code DYN3D has been developed for the analysis of reactivity initiated accidents (RIA) in thermal nuclear reactors. The power distributions are calculated with the help of nodal expansion methods (NEM) for hexagonal and Cartesian geometry. The fuel rod model and the thermohydraulic part provide fuel temperatures, coolant temperatures and densities as well as boron concentrations for the calculation of feedback effects on the basis of cross section libraries generated by cell codes. Safety relevant parameters like maximum fuel and cladding temperatures, critical heat flux and degree of cladding oxidation are estimated. DYN3D can analyze RIA initiated by moved control rods and/or perturbations of the coolant flow. Stationary and transient boundary conditions for the coolant flow, the core inlet temperatures and boron concentrations at the core inlet have to be given. For analyzing more complex transients the code DYN3D is coupled with the plant model ATHLET of the GRS. The extensive validation work accomplished for DYN3D is presented in several examples. Some applications of the code are described. (orig.) [Deutsch] Die Verwendung 3-dimensionaler Kernmodelle zur Untersuchung der Sicherheitsreserven bei Uebergangsprozessen und Stoerfaellen in Kernreaktoren vermeidet konservative Annahmen, die bei der Benutzung des Punktmodells oder 1-dimensionaler Modelle erforderlich sind. Aus diesen Gruenden wurde das 3-dimensionale Rechenprogramm DYN3D fuer die Untersuchung von Reaktivitaetsstoerfaellen in thermischen Reaktoren entwickelt. Die Leistungsverteilung wird mit nodalen Methoden fuer hexagonale oder kartesische Geometrie berechnet. Das Brennstabmodell und der thermohydraulische Teil von DYN3D liefert die Brennstofftemperaturen, Kuehlmitteltemperaturen

  6. The 3D additivist cookbook

    NARCIS (Netherlands)

    Allahyari, Morehshin; Rourke, Daniel; Rasch, Miriam

    The 3D Additivist Cookbook, devised and edited by Morehshin Allahyari & Daniel Rourke, is a free compendium of imaginative, provocative works from over 100 world-leading artists, activists and theorists. The 3D Additivist Cookbook contains .obj and .stl files for the 3D printer, as well as critical

  7. From 2D to 3D: The morphology, proliferation and differentiation of MC3T3-E1 on silk fibroin/chitosan matrices.

    Science.gov (United States)

    Li, Da-Wei; He, Feng-Li; He, Jin; Deng, Xudong; Liu, Ya-Li; Liu, Yang-Yang; Ye, Ya-Jing; Yin, Da-Chuan

    2017-12-15

    It has been widely accepted that cell culture in two-dimensional (2D) conditions may not be able to represent growth in three-dimensional (3D) conditions. Systematic comparisons between 2D and 3D cell cultures are needed to appropriately use the existing 2D results. In this work, we conducted a comparative study between 2D and 3D cell cultures of MC3T3-E1 using the same type of material (a mixture of silk fibroin (SF) and chitosan (CS)). Our results showed 3D SF/CS scaffold exhibited different effects on cell culture compared with the 2D cases. 1) The cells grown in 3D scaffold showed multiple morphologies. 2) The proliferation of cells in 3D scaffold was long-term and sustainable. 3) Cell differentiation occurred throughout the entire 3D scaffold. The results showed that cell culture in 3D SF/CS scaffold exhibited different features than 2D cases and 3D SF/CS scaffold could be a promising material for 3D cell culture. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Effect of cerebral spinal fluid suppression for diffusional kurtosis imaging.

    Science.gov (United States)

    Yang, Alicia W; Jensen, Jens H; Hu, Caixia C; Tabesh, Ali; Falangola, Maria F; Helpern, Joseph A

    2013-02-01

    To evaluate the cerebral spinal fluid (CSF) partial volume effect on diffusional kurtosis imaging (DKI) metrics in white matter and cortical gray matter. Four healthy volunteers participated in this study. Standard DKI and fluid-attenuated inversion recovery (FLAIR) DKI experiments were performed using a twice-refocused-spin-echo diffusion sequence. The conventional diffusion tensor imaging (DTI) metrics of fractional anisotropy (FA), mean, axial, and radial diffusivity (MD, D[symbol in text], D[symbol in text] together with DKI metrics of mean, axial, and radial kurtosis (MK, K[symbol in text], K[symbol in text], were measured and compared. Single image slices located above the lateral ventricles, with similar anatomical features for each subject, were selected to minimize the effect of CSF from the ventricles. In white matter, differences of less than 10% were observed between diffusion metrics measured with standard DKI and FLAIR-DKI sequences, suggesting minimal CSF contamination. For gray matter, conventional DTI metrics differed by 19% to 52%, reflecting significant CSF partial volume effects. Kurtosis metrics, however, changed by 11% or less, indicating greater robustness with respect to CSF contamination. Kurtosis metrics are less sensitive to CSF partial voluming in cortical gray matter than conventional diffusion metrics. The kurtosis metrics may then be more specific indicators of changes in tissue microstructure, provided the effect sizes for the changes are comparable. Copyright © 2012 Wiley Periodicals, Inc.

  9. Qademah Fault 3D Survey

    KAUST Repository

    Hanafy, Sherif M.

    2014-01-01

    Objective: Collect 3D seismic data at Qademah Fault location to 1. 3D traveltime tomography 2. 3D surface wave migration 3. 3D phase velocity 4. Possible reflection processing Acquisition Date: 26 – 28 September 2014 Acquisition Team: Sherif, Kai, Mrinal, Bowen, Ahmed Acquisition Layout: We used 288 receiver arranged in 12 parallel lines, each line has 24 receiver. Inline offset is 5 m and crossline offset is 10 m. One shot is fired at each receiver location. We use the 40 kgm weight drop as seismic source, with 8 to 15 stacks at each shot location.

  10. R3D Align web server for global nucleotide to nucleotide alignments of RNA 3D structures.

    Science.gov (United States)

    Rahrig, Ryan R; Petrov, Anton I; Leontis, Neocles B; Zirbel, Craig L

    2013-07-01

    The R3D Align web server provides online access to 'RNA 3D Align' (R3D Align), a method for producing accurate nucleotide-level structural alignments of RNA 3D structures. The web server provides a streamlined and intuitive interface, input data validation and output that is more extensive and easier to read and interpret than related servers. The R3D Align web server offers a unique Gallery of Featured Alignments, providing immediate access to pre-computed alignments of large RNA 3D structures, including all ribosomal RNAs, as well as guidance on effective use of the server and interpretation of the output. By accessing the non-redundant lists of RNA 3D structures provided by the Bowling Green State University RNA group, R3D Align connects users to structure files in the same equivalence class and the best-modeled representative structure from each group. The R3D Align web server is freely accessible at http://rna.bgsu.edu/r3dalign/.

  11. Hybrid 3D-2D printing for bone scaffolds fabrication

    Science.gov (United States)

    Seleznev, V. A.; Prinz, V. Ya

    2017-02-01

    It is a well-known fact that bone scaffold topography on micro- and nanometer scale influences the cellular behavior. Nano-scale surface modification of scaffolds allows the modulation of biological activity for enhanced cell differentiation. To date, there has been only a limited success in printing scaffolds with micro- and nano-scale features exposed on the surface. To improve on the currently available imperfect technologies, in our paper we introduce new hybrid technologies based on a combination of 2D (nano imprint) and 3D printing methods. The first method is based on using light projection 3D printing and simultaneous 2D nanostructuring of each of the layers during the formation of the 3D structure. The second method is based on the sequential integration of preliminarily created 2D nanostructured films into a 3D printed structure. The capabilities of the developed hybrid technologies are demonstrated with the example of forming 3D bone scaffolds. The proposed technologies can be used to fabricate complex 3D micro- and nanostructured products for various fields.

  12. Proposal of custom made wrist orthoses based on 3D modelling and 3D printing.

    Science.gov (United States)

    Abreu de Souza, Mauren; Schmitz, Cristiane; Marega Pinhel, Marcelo; Palma Setti, Joao A; Nohama, Percy

    2017-07-01

    Accessibility to three-dimensional (3D) technologies, such as 3D scanning systems and additive manufacturing (like 3D printers), allows a variety of 3D applications. For medical applications in particular, these modalities are gaining a lot of attention enabling several opportunities for healthcare applications. The literature brings several cases applying both technologies, but none of them focus on the spreading of how this technology could benefit the health segment. This paper proposes a new methodology, which employs both 3D modelling and 3D printing for building orthoses, which could better fit the demands of different patients. Additionally, there is an opportunity for sharing expertise, as it represents a trendy in terms of the maker-movement. Therefore, as a result of the proposed approach, we present a case study based on a volunteer who needs an immobilization orthosis, which was built for exemplification of the whole process. This proposal also employs freely available 3D models and software, having a strong social impact. As a result, it enables the implementation and effective usability for a variety of built to fit solutions, hitching useful and smarter technologies for the healthcare sector.

  13. The NIH 3D Print Exchange: A Public Resource for Bioscientific and Biomedical 3D Prints

    OpenAIRE

    Coakley, Meghan F.; Hurt, Darrell E.; Weber, Nick; Mtingwa, Makazi; Fincher, Erin C.; Alekseyev, Vsevelod; Chen, David T.; Yun, Alvin; Gizaw, Metasebia; Swan, Jeremy; Yoo, Terry S.; Huyen, Yentram

    2014-01-01

    The National Institutes of Health (NIH) has launched the NIH 3D Print Exchange, an online portal for discovering and creating bioscientifically relevant 3D models suitable for 3D printing, to provide both researchers and educators with a trusted source to discover accurate and informative models. There are a number of online resources for 3D prints, but there is a paucity of scientific models, and the expertise required to generate and validate such models remains a barrier. The NIH 3D Print ...

  14. Comparison of endoscopic endonasal and bifrontal craniotomy approaches for olfactory groove meningiomas: A matched pair analysis of outcomes and frontal lobe changes on MRI.

    Science.gov (United States)

    de Almeida, John R; Carvalho, Felipe; Vaz Guimaraes Filho, Francisco; Kiehl, Tim-Rasmus; Koutourousiou, Maria; Su, Shirley; Vescan, Allan D; Witterick, Ian J; Zadeh, Gelareh; Wang, Eric W; Fernandez-Miranda, Juan C; Gardner, Paul A; Gentili, Fred; Snyderman, Carl H

    2015-11-01

    We compare the outcomes and postoperative MRI changes of endoscopic endonasal (EEA) and bifrontal craniotomy (BFC) approaches for olfactory groove meningiomas (OGM). All patients who underwent either BFC or EEA for OGM were eligible. Matched pairs were created by matching tumor volumes of an EEA patient with a BFC patient, and matching the timing of the postoperative scans. The tumor dimensions, peritumoral edema, resectability issues, and frontal lobe changes were recorded based on preoperative and postoperative MRI. Postoperative fluid-attenuated inversion recovery (FLAIR) hyperintensity and residual cystic cavity (porencephalic cave) volume were compared using univariable and multivariable analyses. From a total of 70 patients (46 EEA, 24 BFC), 10 matched pairs (20 patients) were created. Three patients (30%) in the EEA group and two (20%) in the BFC had postoperative cerebrospinal fluid leaks (p=0.61). Gross total resections were achieved in seven (70%) of the EEA group and nine (90%) of the BFC group (p=0.26), and one patient from each group developed a recurrence. On postoperative MRI, there was no significant difference in FLAIR signal volumes between EEA and BFC approaches (6.9 versus 13.3 cm(3); p=0.17) or in porencephalic cave volumes (1.7 versus 5.0 cm(3); p=0.11) in univariable analysis. However, in a multivariable analysis, EEA was associated with less postoperative FLAIR change (p=0.02) after adjusting for the volume of preoperative edema. This study provides preliminary evidence that EEA is associated with quantifiable improvements in postoperative frontal lobe imaging. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Vrste i tehnike 3D modeliranja

    OpenAIRE

    Bernik, Andrija

    2010-01-01

    Proces stvaranja 3D stvarnih ili imaginarnih objekata naziva se 3D modeliranje. Razvoj računalne tehnologije omogućuje korisniku odabir raznih metoda i tehnika kako bi se postigla optimalna učinkovitost. Odabir je vezan za klasično 3D modeliranje ili 3D skeniranje pomoću specijaliziranih programskih i sklopovskih rješenja. 3D tehnikama modeliranja korisnik može izraditi 3D model na nekoliko načina: koristi poligone, krivulje ili hibrid dviju spomenutih tehnika pod nazivom subdivizijsko modeli...

  16. Recovery after whole-body radiation exposure

    International Nuclear Information System (INIS)

    Sattler, E.L.

    A recovery formula recommended by commissions III and IV of the Federal Ministry of Internal Affairs was tested on goldhamsters. Two test schemes were studied: in the first one recovery took place after irradiating 5 times ''equivalent'' to 100 R at a distance of 20 d with a combined residual damage ''equivalent'' to 100 R, in the second one with ''equivalent'' doses of up to the residual damage of 100 R at a distance of 11 d, which corresponds to a particularly bad recovery phase of the hamster. In both events the residual damage proved to be below the anticipated values. It is being discussed whether these results can be transferred to humans. (MG) [de

  17. 3D print of polymer bonded rare-earth magnets, and 3D magnetic field scanning with an end-user 3D printer

    Science.gov (United States)

    Huber, C.; Abert, C.; Bruckner, F.; Groenefeld, M.; Muthsam, O.; Schuschnigg, S.; Sirak, K.; Thanhoffer, R.; Teliban, I.; Vogler, C.; Windl, R.; Suess, D.

    2016-10-01

    3D print is a recently developed technique, for single-unit production, and for structures that have been impossible to build previously. The current work presents a method to 3D print polymer bonded isotropic hard magnets with a low-cost, end-user 3D printer. Commercially available isotropic NdFeB powder inside a PA11 matrix is characterized, and prepared for the printing process. An example of a printed magnet with a complex shape that was designed to generate a specific stray field is presented, and compared with finite element simulation solving the macroscopic Maxwell equations. For magnetic characterization, and comparing 3D printed structures with injection molded parts, hysteresis measurements are performed. To measure the stray field outside the magnet, the printer is upgraded to a 3D magnetic flux density measurement system. To skip an elaborate adjusting of the sensor, a simulation is used to calibrate the angles, sensitivity, and the offset of the sensor. With this setup, a measurement resolution of 0.05 mm along the z-axes is achievable. The effectiveness of our calibration method is shown. With our setup, we are able to print polymer bonded magnetic systems with the freedom of having a specific complex shape with locally tailored magnetic properties. The 3D scanning setup is easy to mount, and with our calibration method we are able to get accurate measuring results of the stray field.

  18. Using 3D in Visualization

    DEFF Research Database (Denmark)

    Wood, Jo; Kirschenbauer, Sabine; Döllner, Jürgen

    2005-01-01

    to display 3D imagery. The extra cartographic degree of freedom offered by using 3D is explored and offered as a motivation for employing 3D in visualization. The use of VR and the construction of virtual environments exploit navigational and behavioral realism, but become most usefil when combined...... with abstracted representations embedded in a 3D space. The interactions between development of geovisualization, the technology used to implement it and the theory surrounding cartographic representation are explored. The dominance of computing technologies, driven particularly by the gaming industry...

  19. Whole-heart coronary MRA with 3D affine motion correction using 3D image-based navigation.

    Science.gov (United States)

    Henningsson, Markus; Prieto, Claudia; Chiribiri, Amedeo; Vaillant, Ghislain; Razavi, Reza; Botnar, René M

    2014-01-01

    Robust motion correction is necessary to minimize respiratory motion artefacts in coronary MR angiography (CMRA). The state-of-the-art method uses a 1D feet-head translational motion correction approach, and data acquisition is limited to a small window in the respiratory cycle, which prolongs the scan by a factor of 2-3. The purpose of this work was to implement 3D affine motion correction for Cartesian whole-heart CMRA using a 3D navigator (3D-NAV) to allow for data acquisition throughout the whole respiratory cycle. 3D affine transformations for different respiratory states (bins) were estimated by using 3D-NAV image acquisitions which were acquired during the startup profiles of a steady-state free precession sequence. The calculated 3D affine transformations were applied to the corresponding high-resolution Cartesian image acquisition which had been similarly binned, to correct for respiratory motion between bins. Quantitative and qualitative comparisons showed no statistical difference between images acquired with the proposed method and the reference method using a diaphragmatic navigator with a narrow gating window. We demonstrate that 3D-NAV and 3D affine correction can be used to acquire Cartesian whole-heart 3D coronary artery images with 100% scan efficiency with similar image quality as with the state-of-the-art gated and corrected method with approximately 50% scan efficiency. Copyright © 2013 Wiley Periodicals, Inc.

  20. NGT-3D: a simple nematode cultivation system to study Caenorhabditis elegans biology in 3D

    Directory of Open Access Journals (Sweden)

    Tong Young Lee

    2016-04-01

    Full Text Available The nematode Caenorhabditis elegans is one of the premier experimental model organisms today. In the laboratory, they display characteristic development, fertility, and behaviors in a two dimensional habitat. In nature, however, C. elegans is found in three dimensional environments such as rotting fruit. To investigate the biology of C. elegans in a 3D controlled environment we designed a nematode cultivation habitat which we term the nematode growth tube or NGT-3D. NGT-3D allows for the growth of both nematodes and the bacteria they consume. Worms show comparable rates of growth, reproduction and lifespan when bacterial colonies in the 3D matrix are abundant. However, when bacteria are sparse, growth and brood size fail to reach levels observed in standard 2D plates. Using NGT-3D we observe drastic deficits in fertility in a sensory mutant in 3D compared to 2D, and this defect was likely due to an inability to locate bacteria. Overall, NGT-3D will sharpen our understanding of nematode biology and allow scientists to investigate questions of nematode ecology and evolutionary fitness in the laboratory.

  1. Improving Semantic Updating Method on 3d City Models Using Hybrid Semantic-Geometric 3d Segmentation Technique

    Science.gov (United States)

    Sharkawi, K.-H.; Abdul-Rahman, A.

    2013-09-01

    Cities and urban areas entities such as building structures are becoming more complex as the modern human civilizations continue to evolve. The ability to plan and manage every territory especially the urban areas is very important to every government in the world. Planning and managing cities and urban areas based on printed maps and 2D data are getting insufficient and inefficient to cope with the complexity of the new developments in big cities. The emergence of 3D city models have boosted the efficiency in analysing and managing urban areas as the 3D data are proven to represent the real world object more accurately. It has since been adopted as the new trend in buildings and urban management and planning applications. Nowadays, many countries around the world have been generating virtual 3D representation of their major cities. The growing interest in improving the usability of 3D city models has resulted in the development of various tools for analysis based on the 3D city models. Today, 3D city models are generated for various purposes such as for tourism, location-based services, disaster management and urban planning. Meanwhile, modelling 3D objects are getting easier with the emergence of the user-friendly tools for 3D modelling available in the market. Generating 3D buildings with high accuracy also has become easier with the availability of airborne Lidar and terrestrial laser scanning equipments. The availability and accessibility to this technology makes it more sensible to analyse buildings in urban areas using 3D data as it accurately represent the real world objects. The Open Geospatial Consortium (OGC) has accepted CityGML specifications as one of the international standards for representing and exchanging spatial data, making it easier to visualize, store and manage 3D city models data efficiently. CityGML able to represents the semantics, geometry, topology and appearance of 3D city models in five well-defined Level-of-Details (LoD), namely LoD0

  2. Vitamin D(3) is more potent than vitamin D(2) in humans.

    Science.gov (United States)

    Heaney, Robert P; Recker, Robert R; Grote, James; Horst, Ronald L; Armas, Laura A G

    2011-03-01

    Current unitage for the calciferols suggests that equimolar quantities of vitamins D(2) (D2) and D(3) (D3) are biologically equivalent. Published studies yield mixed results. The aim of the study was to compare the potencies of D2 and D3. The trial used a single-blind, randomized design in 33 healthy adults. Calciferols were dosed at 50,000 IU/wk for 12 wk. Principal outcome variables were area under the curve for incremental total 25-hydroxyvitamin D [25(OH)D] and change in calciferol content of sc fat. Incremental mean (sd) 25(OH)D area under the curve at 12 wk was 1366 ng · d/ml (516) for the D2-treated group and 2136 (606) for the D3 (P < 0.001). Mean (sd) steady-state 25(OH)D increments showed similar differences: 24 ng/ml for D2 (10.3) and 45 ng/ml (16.2) for D3 (P <0.001). Subcutaneous fat content of D2 rose by 50 μg/kg in the D2-treated group, and D3 content rose by 104 μg/kg in the D3-treated group. Total calciferol in fat rose by only 33 ng/kg in the D2-treated, whereas it rose by 104 μg/kg in the D3-treated group. Extrapolating to total body fat D3, storage amounted to just 17% of the administered dose. D3 is approximately 87% more potent in raising and maintaining serum 25(OH)D concentrations and produces 2- to 3-fold greater storage of vitamin D than does equimolar D2. For neither was there evidence of sequestration in fat, as had been postulated for doses in this range. Given its greater potency and lower cost, D3 should be the preferred treatment option when correcting vitamin D deficiency.

  3. Measurement of the hyperfine structure of the 4d2D3/2,5/2 levels and isotope shifts of the 4p2P3/2->4d2D3/2 and 4p2P3/2->4d2D5/2 transitions in gallium 69 and 71

    International Nuclear Information System (INIS)

    Rehse, Steven J.; Fairbank, William M.; Lee, Siu Au

    2001-01-01

    The hyperfine structure of the 4d 2 D 3/2,5/2 levels of 69,71 Ga is determined. The 4p 2 P 3/2 ->4d 2 D 3/2 (294.50-nm) and 4p 2 P 3/2 ->4d 2 D 5/2 (294.45-nm) transitions are studied by laser-induced fluorescence in an atomic Ga beam. The hyperfine A constant measured for the 4d 2 D 5/2 level is 77.3±0.9 MHz for 69 Ga and 97.9± 0.7 MHz for 71 Ga (3σ errors). The A constant measured for the 4d 2 D 3/2 level is -36.3±2.2 MHz for 69 Ga and -46.2±3.8 MHz for 71 Ga. These measurements correct sign errors in the previous determination of these constants. For 69 Ga the hyperfine B constants measured for the 4d 2 D 5/2 and the 4d 2 D 3/2 levels are 5.3±4.1 MHz and 4.6±4.2 MHz, respectively. The isotope shift is determined to be 114±8 MHz for the 4p 2 P 3/2 ->4d 2 D 3/2 transition and 115±7 MHz for the 4p 2 P 3/2 ->4d 2 D 5/2 transition. The lines of 71 Ga are shifted to the blue. This is in agreement with previous measurement. [copyright] 2001 Optical Society of America

  4. COBACORE Community Based Comprehensive Recovery : D3.1: Mock-ups of interface of COBACORE workspace and functional behaviour of CORBCORE - WP3 Concept development and support mechanisms

    NARCIS (Netherlands)

    Neef, R.M.; Streefkerk, J.W.; Buul-Besseling, K. van; Rijken, M.

    2014-01-01

    D3.1 describes the core feature set of the COBACORE platform, the underlying assumptions and information elements, and introduces a number of interaction patterns. D3.1 is a guiding document that serves as a blueprint for the actual implementation of the COBACORE platform, and that can be used by

  5. Either brain-derived neurotrophic factor or neurotrophin-3 only neurotrophin-producing grafts promote locomotor recovery in untrained spinalized cats.

    Science.gov (United States)

    Ollivier-Lanvin, Karen; Fischer, Itzhak; Tom, Veronica; Houlé, John D; Lemay, Michel A

    2015-01-01

    Background. Transplants of cellular grafts expressing a combination of 2 neurotrophic factors, brain-derived neurotrophic factor (BDNF) and neurotrophin-3 (NT-3) have been shown to promote and enhance locomotor recovery in untrained spinalized cats. Based on the time course of recovery and the absence of axonal growth through the transplants, we hypothesized that recovery was due to neurotrophin-mediated plasticity within the existing locomotor circuitry of the lumbar cord. Since BDNF and NT-3 have different effects on axonal sprouting and synaptic connectivity/strengthening, it becomes important to ascertain the contribution of each individual neurotrophins to recovery. Objective. We studied whether BDNF or NT-3 only producing cellular grafts would be equally effective at restoring locomotion in untrained spinal cats. Methods. Rat fibroblasts secreting one of the 2 neurotrophins were grafted into the T12 spinal transection site of adult cats. Four cats in each group (BDNF alone or NT-3 alone) were evaluated. Locomotor recovery was tested on a treadmill at 3 and 5 weeks post-transection/grafting. Results. Animals in both groups were capable of plantar weight-bearing stepping at speed up to 0.8 m/s as early as 3 weeks and locomotor capabilities were similar at 3 and 5 weeks for both types of graft. Conclusions. Even without locomotor training, either BDNF or NT-3 only producing grafts promote locomotor recovery in complete spinal animals. More clinically applicable delivery methods need to be developed. © The Author(s) 2014.

  6. 3s--3p, 3p--3d, and 3d--4f transitions of sodiumlike ions

    International Nuclear Information System (INIS)

    Reader, J.; Kaufman, V.; Sugar, J.; Olof Ekberg, J.; Feldman, U.; Brown, C.M.; Seely, J.F.; Rowan, W.L.

    1987-01-01

    New measurements have been made for wavelengths of the 3s--3p, 3p--3d, and 3d--4f transitions of the sodiumlike ions Cu/sup 18+/, Zn/sup 19+/, Ga/sup 20+/, Ge/sup 21+/, As/sup 22+/, Se/sup 23+/, Br/sup 24+/, Kr/sup 25+/, Y/sup 28+/, Zr/sup 29+/, Nb/sup 30+/, Mo/sup 31+/, Ru/sup 33+/, Rh/sup 34+/, Pd/sup 35+/, Ag/sup 36+/, and Sn/sup 39+/. The measurements were made by photographing laser-produced plasmas and tokamak plasmas with grazing-incidence spectrographs. The energies of the transitions were also calculated with Dirac--Fock computer codes. By fitting the differences between the observed and calculated wave numbers to simple formulas, least-squares-fitted wavelengths for all sodiumlike ions from Ar 7+ to Xe/sup 43+/ were determined. The estimated uncertainty of the fitted wavelengths is +- 0.007 A, which makes them useful as reference values. The wavelengths range from 9 to 713 A

  7. Full-parallax 3D display from stereo-hybrid 3D camera system

    Science.gov (United States)

    Hong, Seokmin; Ansari, Amir; Saavedra, Genaro; Martinez-Corral, Manuel

    2018-04-01

    In this paper, we propose an innovative approach for the production of the microimages ready to display onto an integral-imaging monitor. Our main contribution is using a stereo-hybrid 3D camera system, which is used for picking up a 3D data pair and composing a denser point cloud. However, there is an intrinsic difficulty in the fact that hybrid sensors have dissimilarities and therefore should be equalized. Handled data facilitate to generating an integral image after projecting computationally the information through a virtual pinhole array. We illustrate this procedure with some imaging experiments that provide microimages with enhanced quality. After projection of such microimages onto the integral-imaging monitor, 3D images are produced with great parallax and viewing angle.

  8. 3D biometrics systems and applications

    CERN Document Server

    Zhang, David

    2013-01-01

    Includes discussions on popular 3D imaging technologies, combines them with biometric applications, and then presents real 3D biometric systems Introduces many efficient 3D feature extraction, matching, and fusion algorithms Techniques presented have been supported by experimental results using various 3D biometric classifications

  9. Automated classification of RNA 3D motifs and the RNA 3D Motif Atlas

    Science.gov (United States)

    Petrov, Anton I.; Zirbel, Craig L.; Leontis, Neocles B.

    2013-01-01

    The analysis of atomic-resolution RNA three-dimensional (3D) structures reveals that many internal and hairpin loops are modular, recurrent, and structured by conserved non-Watson–Crick base pairs. Structurally similar loops define RNA 3D motifs that are conserved in homologous RNA molecules, but can also occur at nonhomologous sites in diverse RNAs, and which often vary in sequence. To further our understanding of RNA motif structure and sequence variability and to provide a useful resource for structure modeling and prediction, we present a new method for automated classification of internal and hairpin loop RNA 3D motifs and a new online database called the RNA 3D Motif Atlas. To classify the motif instances, a representative set of internal and hairpin loops is automatically extracted from a nonredundant list of RNA-containing PDB files. Their structures are compared geometrically, all-against-all, using the FR3D program suite. The loops are clustered into motif groups, taking into account geometric similarity and structural annotations and making allowance for a variable number of bulged bases. The automated procedure that we have implemented identifies all hairpin and internal loop motifs previously described in the literature. All motif instances and motif groups are assigned unique and stable identifiers and are made available in the RNA 3D Motif Atlas (http://rna.bgsu.edu/motifs), which is automatically updated every four weeks. The RNA 3D Motif Atlas provides an interactive user interface for exploring motif diversity and tools for programmatic data access. PMID:23970545

  10. Graphene Oxide: An All-in-One Processing Additive for 3D Printing.

    Science.gov (United States)

    García-Tuñón, Esther; Feilden, Ezra; Zheng, Han; D'Elia, Eleonora; Leong, Alan; Saiz, Eduardo

    2017-09-27

    Many 3D printing technologies are based on the development of inks and pastes to build objects through droplet or filament deposition (the latter also known as continuous extrusion, robocasting, or direct ink writing). Controlling and tuning rheological behavior is key for successful manufacturing using these techniques. Different formulations have been proposed, but the search continues for approaches that are clean, flexible, robust and that can be adapted to a wide range of materials. Here, we show how graphene oxide (GO) enables the formulation of water-based pastes to print a wide variety of materials (polymers, ceramics, and steel) using robocasting. This work combines flow and oscillatory rheology to provide further insights into the rheological behavior of suspensions combining GO with other materials. Graphene oxide can be used to manipulate the viscoelastic response, enabling the formulation of pastes with excellent printing behavior that combine shear thinning flow and a fast recovery of their elastic properties. These inks do not contain other additives, only GO and the material of interest. As a proof of concept, we demonstrate the 3D printing of additive-free graphene oxide structures as well as polymers, ceramics, and steel. Due to its amphiphilic nature and 2D structure, graphene oxide plays multiple roles, behaving as a dispersant, viscosifier, and binder. It stabilizes suspensions of different powders, modifies the flow and viscoelasticity of materials with different chemistries, particle sizes and shapes, and binds the particles together, providing green strength for manual handling. This approach enables printing complex 3D ceramic structures using robocasting with similar properties to alternative formulations, thus demonstrating the potential of using 2D colloids in materials manufacturing.

  11. 3-D printers for libraries

    CERN Document Server

    Griffey, Jason

    2014-01-01

    As the maker movement continues to grow and 3-D printers become more affordable, an expanding group of hobbyists is keen to explore this new technology. In the time-honored tradition of introducing new technologies, many libraries are considering purchasing a 3-D printer. Jason Griffey, an early enthusiast of 3-D printing, has researched the marketplace and seen several systems first hand at the Consumer Electronics Show. In this report he introduces readers to the 3-D printing marketplace, covering such topics asHow fused deposition modeling (FDM) printing workBasic terminology such as build

  12. Registration of 3D spectral OCT volumes using 3D SIFT feature point matching

    Science.gov (United States)

    Niemeijer, Meindert; Garvin, Mona K.; Lee, Kyungmoo; van Ginneken, Bram; Abràmoff, Michael D.; Sonka, Milan

    2009-02-01

    The recent introduction of next generation spectral OCT scanners has enabled routine acquisition of high resolution, 3D cross-sectional volumetric images of the retina. 3D OCT is used in the detection and management of serious eye diseases such as glaucoma and age-related macular degeneration. For follow-up studies, image registration is a vital tool to enable more precise, quantitative comparison of disease states. This work presents a registration method based on a recently introduced extension of the 2D Scale-Invariant Feature Transform (SIFT) framework1 to 3D.2 The SIFT feature extractor locates minima and maxima in the difference of Gaussian scale space to find salient feature points. It then uses histograms of the local gradient directions around each found extremum in 3D to characterize them in a 4096 element feature vector. Matching points are found by comparing the distance between feature vectors. We apply this method to the rigid registration of optic nerve head- (ONH) and macula-centered 3D OCT scans of the same patient that have only limited overlap. Three OCT data set pairs with known deformation were used for quantitative assessment of the method's robustness and accuracy when deformations of rotation and scaling were considered. Three-dimensional registration accuracy of 2.0+/-3.3 voxels was observed. The accuracy was assessed as average voxel distance error in N=1572 matched locations. The registration method was applied to 12 3D OCT scans (200 x 200 x 1024 voxels) of 6 normal eyes imaged in vivo to demonstrate the clinical utility and robustness of the method in a real-world environment.

  13. Stereolithographic hydrogel printing of 3D culture chips with biofunctionalized complex 3D perfusion networks

    DEFF Research Database (Denmark)

    Zhang, Rujing; Larsen, Niels Bent

    2017-01-01

    the required freedom in design, detail and chemistry for fabricating truly 3D constructs have remained limited. Here, we report a stereolithographic high-resolution 3D printing technique utilizing poly(ethylene glycol) diacrylate (PEGDA, MW 700) to manufacture diffusion-open and mechanically stable hydrogel...... and material flexibility by embedding a highly compliant cell-laden gelatin hydrogel within the confines of a 3D printed resilient PEGDA hydrogel chip of intermediate compliance. Overall, our proposed strategy represents an automated, cost-effective and high resolution technique to manufacture complex 3D......Three-dimensional (3D) in vitro models capturing both the structural and dynamic complexity of the in vivo situation are in great demand as an alternative to animal models. Despite tremendous progress in engineering complex tissue/organ models in the past decade, approaches that support...

  14. 3D-ICONS Ireland – fulfilling the potential of a rich 3D resource

    Directory of Open Access Journals (Sweden)

    Anthony Corns

    2017-03-01

    Full Text Available As a partner in the EU co-funded 3D-ICONS project, the Discovery Programme undertook the 3D documentation of some of the most iconic cultural heritage sites in Ireland. This pan-European project aimed to establish a complete pipeline for the production of 3D replicas of archaeological monuments and historic buildings, and to publish the content to Europeana for public access. The list of Irish icons range from wider cultural landscapes to smaller ornately carved stones and includes a wide range of chronological periods: from Neolithic rock art from 2500 BC to Derry's 17th-century fortifications. The primary digitisation methods include airborne laser scanning (ALS, phase-based terrestrial laser scanning (Faro Focus 3D and close range structured light scanning (Artec EVA. These are now mainstream approaches for surveying historic landscapes, structures and objects, generating precise, high-resolution point cloud data, primarily for viewing and interaction in proprietary software applications. The challenge was to convert these complex high-volume datasets into textured 3D models, retaining the geometric integrity of the original data. The article highlights the development of a pipeline to produce a lightweight 3D model that enables the public to interact with a photorealistic model based upon accurate survey and texture data. 3D-ICONS ended in January 2015, but a new website 3dicons.ie was launched to offer continued access to the Irish 3D models and associated content and media generated during the project. The article will consider the impact of this online content, particularly how it has been used as a teaching aid in secondary schools and how this may be extended in the future. It will also demonstrate how content from the project has been remodelled to develop an interactive and immersive experience for the great mound at Knowth, a development in partnership with the operators of the Brú na Bóinne visitor centre.

  15. MR imaging characteristics of protoplasmic astrocytomas

    Energy Technology Data Exchange (ETDEWEB)

    Tay, Kevin L. [Royal Melbourne Hospital, Department of Radiology, Parkville, Victoria (Australia); Royal North Shore Hospital, Department of Radiology, St Leonards, New South Wales (Australia); Tsui, Alpha [Royal Melbourne Hospital, Department of Pathology, Parkville, Victoria (Australia); Phal, Pramit M.; Tress, Brian M. [Royal Melbourne Hospital, Department of Radiology, Parkville, Victoria (Australia); Drummond, Katharine J. [Royal Melbourne Hospital, Department of Neurosurgery, Parkville, Victoria (Australia)

    2011-06-15

    Protoplasmic astrocytomas are a poorly recognized and uncommon subtype of astrocytoma. While usually categorized with other low-grade gliomas, there is literature to suggest that protoplasmic astrocytomas have differences in biology compared to other gliomas in this group. This paper presents the MR imaging characteristics of a series of eight protoplasmic astrocytomas. We retrospectively reviewed MR images and histopathology of eight consecutive cases of histologically proven protoplasmic astrocytomas. Patients ranged from 17 to 51 years of age with a 5:3 male to female ratio. The tumors were located in the frontal or temporal lobes and tended to be large, well defined, and had a very high signal on T2 (close to cerebrospinal fluid). Generally, a large proportion of the tumor showed substantial signal suppression on T2 fluid-attenuated inversion recovery (FLAIR). Six of the eight lesions also demonstrated a partial or complete rim of reduced apparent diffusion coefficient (ADC) around the T2 FLAIR suppressing portion. The possibility that a primary cerebral neoplasm represents a protoplasmic astrocytoma should be considered in a patient with a large frontal or temporal tumor that has a very high signal on T2 with a large proportion of the tumor showing substantial T2 FLAIR suppression. A further clue is a partial or complete rim of reduced ADC. (orig.)

  16. Blender 3D cookbook

    CERN Document Server

    Valenza, Enrico

    2015-01-01

    This book is aimed at the professionals that already have good 3D CGI experience with commercial packages and have now decided to try the open source Blender and want to experiment with something more complex than the average tutorials on the web. However, it's also aimed at the intermediate Blender users who simply want to go some steps further.It's taken for granted that you already know how to move inside the Blender interface, that you already have 3D modeling knowledge, and also that of basic 3D modeling and rendering concepts, for example, edge-loops, n-gons, or samples. In any case, it'

  17. 3D CISS, 3D MP-PAGE and 2D TSE for MRI prior to Cochlear implantation

    International Nuclear Information System (INIS)

    Seitz, J.; Held, P.; Voelk, M.; Lenhart, M.; Strotzer, M.; Waldeck, A.

    2000-01-01

    Purpose: The aim of this study was to determine the presurgical predictive value of high resolution MRI in patients scheduled for chochlear implantation. Method and material: The presurgical MRI (3D CISS, 3D MP-RAGE with and without i.v. contrast medium, 2D TSE) findings of 54 patients and the intraoperative situation reported by the surgeon were compared retrospectively. The surgical and functional success of the cochlear implantation was evaluated. Results: We found a high degree of correlation between MRI and intraoperative findings concerning the patency of the whole cochlea and anomalies as well as in the diagnosis of pathology of the cochlear, vestibular and facial nerves and in anomalies of the internal auditory canal. However, in four out of 54 patients there was a false negative prediction regarding the patency of the cochlea. The sensitivity was 50% (4/8), the specificity 100% (46/46). Concerning the surgical success the accuracy was 100%. In all patients MRI gave sufficient anatomical information to the surgeon concerning the jugular bulb and the facial nerve. Conclusion: A high-resolution MRI protocol consisting of coronal 2D T2w TSE, 3D T2*w transverse CISS; plain and contrast enhanced sagittal T1w 3D MP-RAGE is recommended for the evaluation of candidates scheduled for cochlear implantation. (orig.) [de

  18. Pembuatan Aplikasi Catalog 3D Desain Rumah Sebagai Sarana Promosi Dengan Menggunakan Unity 3D

    Directory of Open Access Journals (Sweden)

    Siryantini Nurul Adnin

    2016-03-01

    Full Text Available This study incorporate AR into a technology home Catalog sales, thus Catalog home is becoming more real with 3D objects in it. This research aims to produce an application that can display a 3D model of a house that can help buyers to know well the home to be purchased, and will simplify the home seller as a media campaign to consumers. 3D objects used to develop two kinds of Software that Sweet Home 3D and Blender, whereas to create application in programming used Unity 3D Software using the C # programming language. Application home design Catalog is made through several stages of design 3D objects, Marker workmanship and application design. The end result consists of two forms, namely in the form of physical (in the form of print media Catalog that contains a marker on some pages and Augmented Reality applications based on Android in the form of .apk which is then installed on Smartphones, where the two are complementary.

  19. A spherical harmonics intensity model for 3D segmentation and 3D shape analysis of heterochromatin foci.

    Science.gov (United States)

    Eck, Simon; Wörz, Stefan; Müller-Ott, Katharina; Hahn, Matthias; Biesdorf, Andreas; Schotta, Gunnar; Rippe, Karsten; Rohr, Karl

    2016-08-01

    The genome is partitioned into regions of euchromatin and heterochromatin. The organization of heterochromatin is important for the regulation of cellular processes such as chromosome segregation and gene silencing, and their misregulation is linked to cancer and other diseases. We present a model-based approach for automatic 3D segmentation and 3D shape analysis of heterochromatin foci from 3D confocal light microscopy images. Our approach employs a novel 3D intensity model based on spherical harmonics, which analytically describes the shape and intensities of the foci. The model parameters are determined by fitting the model to the image intensities using least-squares minimization. To characterize the 3D shape of the foci, we exploit the computed spherical harmonics coefficients and determine a shape descriptor. We applied our approach to 3D synthetic image data as well as real 3D static and real 3D time-lapse microscopy images, and compared the performance with that of previous approaches. It turned out that our approach yields accurate 3D segmentation results and performs better than previous approaches. We also show that our approach can be used for quantifying 3D shape differences of heterochromatin foci. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Weighted f-values, A-values, and line strengths for the E1 transitions among 3d6, 3d54s, and 3d54p levels of Fe III

    International Nuclear Information System (INIS)

    Deb, Narayan C.; Hibbert, Alan

    2009-01-01

    Weighted oscillator strengths, weighted radiative rates, and line strengths for all the E1 transitions between 285 fine-structure levels belonging to the 3d 6 , 3d 5 4s, and 3d 5 4p configurations of Fe III are presented, in ascending order of wavelength. Calculations have been undertaken using the general configuration interaction (CI) code CIV3. The large configuration set is constructed by allowing single and double replacements from any of 3d 6 , 3d 5 4s, 3d 5 4p, and 3d 5 4d configurations to nl orbitals with n≤5,l≤3 as well as 6p. Additional selective promotions from 3s and 3p subshells are also included in the CI expansions to incorporate the important correlation effects in the n=3 shell. Results of some strong transitions between levels of 3d 6 , 3d 5 4s, and 3d 5 4p configurations are also presented and compared with other available calculations. It is found that large disagreements occur in many transitions among the existing calculations

  1. Improving 3d Spatial Queries Search: Newfangled Technique of Space Filling Curves in 3d City Modeling

    Science.gov (United States)

    Uznir, U.; Anton, F.; Suhaibah, A.; Rahman, A. A.; Mioc, D.

    2013-09-01

    The advantages of three dimensional (3D) city models can be seen in various applications including photogrammetry, urban and regional planning, computer games, etc.. They expand the visualization and analysis capabilities of Geographic Information Systems on cities, and they can be developed using web standards. However, these 3D city models consume much more storage compared to two dimensional (2D) spatial data. They involve extra geometrical and topological information together with semantic data. Without a proper spatial data clustering method and its corresponding spatial data access method, retrieving portions of and especially searching these 3D city models, will not be done optimally. Even though current developments are based on an open data model allotted by the Open Geospatial Consortium (OGC) called CityGML, its XML-based structure makes it challenging to cluster the 3D urban objects. In this research, we propose an opponent data constellation technique of space-filling curves (3D Hilbert curves) for 3D city model data representation. Unlike previous methods, that try to project 3D or n-dimensional data down to 2D or 3D using Principal Component Analysis (PCA) or Hilbert mappings, in this research, we extend the Hilbert space-filling curve to one higher dimension for 3D city model data implementations. The query performance was tested using a CityGML dataset of 1,000 building blocks and the results are presented in this paper. The advantages of implementing space-filling curves in 3D city modeling will improve data retrieval time by means of optimized 3D adjacency, nearest neighbor information and 3D indexing. The Hilbert mapping, which maps a subinterval of the [0, 1] interval to the corresponding portion of the d-dimensional Hilbert's curve, preserves the Lebesgue measure and is Lipschitz continuous. Depending on the applications, several alternatives are possible in order to cluster spatial data together in the third dimension compared to its

  2. Electric-dipole allowed and intercombination transitions among the 3d5, 3d44s and 3d44p levels of Fe IV

    International Nuclear Information System (INIS)

    Deb, Narayan C.; Hibbert, Alan

    2010-01-01

    Oscillator strengths and transition rates for the electric-dipole (E1) allowed and intercombination transitions among 3d 5 , 3d 4 4s and 3d 4 4p levels of Fe IV are calculated using the CIV3 code of Hibbert and coworkers. Using the Hartree-Fock functions up to 3d orbitals we have also optimized 4s, 4p, 4d, 4f, 5s, 5p and 5d orbitals of which 4s and 4p are taken to be spectroscopic and the remaining orbitals represent corrections to the spectroscopic orbitals or the correlation effects. The J-dependent levels of 108 LS states are included in the calculation and the relativistic effects are accounted for via the Breit-Pauli operator. Configurations are chosen in two steps: (a) two promotions were allowed from the 3p, 3d, 4s and 4p subshells, using all the orbitals; and (b) selective promotions from the 3s subshell are included, but only to the 3s and 4s orbitals. The ab initio fine-structure levels are then fine tuned to reproduce observed energy levels as closely as possible, and the resulting wavefunctions are used to calculate oscillator strengths and transition rates for all possible E1 transitions. For many of these transitions, the present results show good agreement between the length and velocity forms while for some transitions, some large disagreements are found with other available results. The complete list of weighted oscillator strengths, transition rates, and line strengths for transitions among the fine structure levels of the three lowest configurations are presented in ascending order of wavelength.

  3. Comparison of 3D TOF-MRA and 3D CE-MRA at 3 T for imaging of intracranial aneurysms

    International Nuclear Information System (INIS)

    Cirillo, Mario; Scomazzoni, Francesco; Cirillo, Luigi; Cadioli, Marcello; Simionato, Franco; Iadanza, Antonella; Kirchin, Miles; Righi, Claudio; Anzalone, Nicoletta

    2013-01-01

    Purpose: To compare 3 T elliptical-centric CE MRA with 3 T TOF MRA for the detection and characterization of unruptured intracranial aneurysms (UIAs), by using digital subtracted angiography (DSA) as reference. Materials and methods: Twenty-nine patients (12 male, 17 female; mean age: 62 years) with 41 aneurysms (34 saccular, 7 fusiform; mean diameter: 8.85 mm [range 2.0–26.4 mm]) were evaluated with MRA at 3 T each underwent 3D TOF-MRA examination without contrast and then a 3D contrast-enhanced (CE-MRA) examination with 0.1 mmol/kg bodyweight gadobenate dimeglumine and k-space elliptic mapping (Contrast ENhanced Timing Robust Angiography [CENTRA]). Both TOF and CE-MRA images were used to evaluate morphologic features that impact the risk of rupture and the selection of a treatment. Almost half (20/41) of UIAs were located in the internal carotid artery, 7 in the anterior communicating artery, 9 in the middle cerebral artery and 4 in the vertebro-basilar arterial system. All patients also underwent DSA before or after the MR examination. Results: The CE-MRA results were in all cases consistent with the DSA dataset. No differences were noted between 3D TOF-MRA and CE-MRA concerning the detection and location of the 41 aneurysms or visualization of the parental artery. Differences were apparent concerning the visualization of morphologic features, especially for large aneurysms (>13 mm). An irregular sac shape was demonstrated for 21 aneurysms on CE-MRA but only 13/21 aneurysms on 3D TOF-MRA. Likewise, CE-MRA permitted visualization of an aneurismal neck and calculation of the sac/neck ratio for all 34 aneurysms with a neck demonstrated at DSA. Conversely, a neck was visible for only 24/34 aneurysms at 3D TOF-MRA. 3D CE-MRA detected 15 aneurysms with branches originating from the sac and/or neck, whereas branches were recognized in only 12/15 aneurysms at 3D TOF-MRA. Conclusion: For evaluation of intracranial aneurysms at 3 T, 3D CE-MRA is superior to 3D TOF

  4. Quantitative Magnetization Transfer Imaging in Human Brain at 3 T via Selective Inversion Recovery

    OpenAIRE

    Dortch, Richard D.; Li, Ke; Gochberg, Daniel F.; Welch, E. Brian; Dula, Adrienne N.; Tamhane, Ashish A.; Gore, John C.; Smith, Seth A.

    2011-01-01

    Quantitative magnetization transfer imaging yields indices describing the interactions between free water protons and immobile, macromolecular protons—including the macromolecular to free pool size ratio (PSR) and the rate of magnetization transfer between pools kmf. This study describes the first implementation of the selective inversion recovery quantitative magnetization transfer method on a clinical 3.0-T scanner in human brain in vivo. Selective inversion recovery data were acquired at 1...

  5. Recovery of Agricultural Odors and Odorous Compounds from Polyvinyl Fluoride Film Bags

    Science.gov (United States)

    Parker, David B.; Perschbacher-Buser, Zena L.; Cole, N. Andy; Koziel, Jacek A.

    2010-01-01

    Accurate sampling methods are necessary when quantifying odor and volatile organic compound emissions at agricultural facilities. The commonly accepted methodology in the U.S. has been to collect odor samples in polyvinyl fluoride bags (PVF, brand name Tedlar®) and, subsequently, analyze with human panelists using dynamic triangular forced-choice olfactometry. The purpose of this research was to simultaneously quantify and compare recoveries of odor and odorous compounds from both commercial and homemade PVF sampling bags. A standard gas mixture consisting of p-cresol (40 μg m−3) and seven volatile fatty acids: acetic (2,311 μg m−3), propionic (15,800 μg m−3), isobutyric (1,686 μg m−3), butyric (1,049 μg m−3), isovaleric (1,236 μg m−3), valeric (643 μg m−3), and hexanoic (2,158 μg m−3) was placed in the PVF bags at times of 1 h, 1 d, 2 d, 3 d, and 7 d prior to compound and odor concentration analyses. Compound concentrations were quantified using sorbent tubes and gas chromatography/mass spectrometry. Odor concentration, intensity, and hedonic tone were measured using a panel of trained human subjects. Compound recoveries ranged from 2 to 40% after 1 h and 0 to 14% after 7 d. Between 1 h and 7 d, odor concentrations increased by 45% in commercial bags, and decreased by 39% in homemade bags. Minimal changes were observed in intensity and hedonic tone over the same time period. These results suggest that PVF bags can bias individual compound concentrations and odor as measured by dynamic triangular forced-choice olfactometry. PMID:22163671

  6. 3D printing in dentistry.

    Science.gov (United States)

    Dawood, A; Marti Marti, B; Sauret-Jackson, V; Darwood, A

    2015-12-01

    3D printing has been hailed as a disruptive technology which will change manufacturing. Used in aerospace, defence, art and design, 3D printing is becoming a subject of great interest in surgery. The technology has a particular resonance with dentistry, and with advances in 3D imaging and modelling technologies such as cone beam computed tomography and intraoral scanning, and with the relatively long history of the use of CAD CAM technologies in dentistry, it will become of increasing importance. Uses of 3D printing include the production of drill guides for dental implants, the production of physical models for prosthodontics, orthodontics and surgery, the manufacture of dental, craniomaxillofacial and orthopaedic implants, and the fabrication of copings and frameworks for implant and dental restorations. This paper reviews the types of 3D printing technologies available and their various applications in dentistry and in maxillofacial surgery.

  7. Growth and physiological response of tomato plants to different periods of nitrogen starvation and recovery

    NARCIS (Netherlands)

    Martinez, V.; Amor, del F.M.; Marcelis, L.F.M.

    2005-01-01

    Young, vegetative-state tomato plants, starved of N for 1, 3 or 7 d, followed, in each case, by a 7-d recovery period with nutrient solution containing N, were examined. Relative growth rate (RGR), leaf photosynthesis and leaf expansion were reduced after only 1 d of N starvation.Tissue N

  8. 3D Spectroscopy in Astronomy

    Science.gov (United States)

    Mediavilla, Evencio; Arribas, Santiago; Roth, Martin; Cepa-Nogué, Jordi; Sánchez, Francisco

    2011-09-01

    Preface; Acknowledgements; 1. Introductory review and technical approaches Martin M. Roth; 2. Observational procedures and data reduction James E. H. Turner; 3. 3D Spectroscopy instrumentation M. A. Bershady; 4. Analysis of 3D data Pierre Ferruit; 5. Science motivation for IFS and galactic studies F. Eisenhauer; 6. Extragalactic studies and future IFS science Luis Colina; 7. Tutorials: how to handle 3D spectroscopy data Sebastian F. Sánchez, Begona García-Lorenzo and Arlette Pécontal-Rousset.

  9. 2D to 3D transition of polymeric carbon nitride nanosheets

    Energy Technology Data Exchange (ETDEWEB)

    Chamorro-Posada, Pedro [Dpto. de Teoría de la Señal y Comunicaciones e IT, Universidad de Valladolid, ETSI Telecomunicación, Paseo Belén 15, 47011 Valladolid (Spain); Vázquez-Cabo, José [Dpto. de Teoría de la Señal y Comunicaciones, Universidad de Vigo, ETSI Telecomunicación, Lagoas Marcosende s/n, Vigo (Spain); Sánchez-Arévalo, Francisco M. [Instituto de Investigaciones en Materiales (IIM), Universidad Nacional Autónoma de México, Apdo. Postal 70–360, Cd. Universitaria, México D.F. 04510 (Mexico); Martín-Ramos, Pablo [Dpto. de Teoría de la Señal y Comunicaciones e IT, Universidad de Valladolid, ETSI Telecomunicación, Paseo Belén 15, 47011 Valladolid (Spain); Laboratorio de Materiales Avanzados (Advanced Materials Laboratory) ETSIIAA, Universidad de Valladolid, Avenida de Madrid 44, 34004 Palencia (Spain); Martín-Gil, Jesús; Navas-Gracia, Luis M. [Laboratorio de Materiales Avanzados (Advanced Materials Laboratory) ETSIIAA, Universidad de Valladolid, Avenida de Madrid 44, 34004 Palencia (Spain); Dante, Roberto C., E-mail: rcdante@yahoo.com [Laboratorio de Materiales Avanzados (Advanced Materials Laboratory) ETSIIAA, Universidad de Valladolid, Avenida de Madrid 44, 34004 Palencia (Spain)

    2014-11-15

    The transition from a prevalent turbostratic arrangement with low planar interactions (2D) to an array of polymeric carbon nitride nanosheets with stronger interplanar interactions (3D), occurring for samples treated above 650 °C, was detected by terahertz-time domain spectroscopy (THz-TDS). The simulated 3D material made of stacks of shifted quasi planar sheets composed of zigzagged polymer ribbons, delivered a XRD simulated pattern in relatively good agreement with the experimental one. The 2D to 3D transition was also supported by the simulation of THz-TDS spectra obtained from quantum chemistry calculations, in which the same broad bands around 2 THz and 1.5 THz were found for 2D and 3D arrays, respectively. This transition was also in accordance with the tightening of the interplanar distance probably due to an interplanar π bond contribution, as evidenced also by a broad absorption around 2.6 eV in the UV–vis spectrum, which appeared in the sample treated at 650 °C, and increased in the sample treated at 700 °C. The band gap was calculated for 1D and 2D cases. The value of 3.374 eV for the 2D case is, within the model accuracy and precision, in a relative good agreement with the value of 3.055 eV obtained from the experimental results. - Graphical abstract: 2D lattice mode vibrations and structural changes correlated with the so called “2D to 3D transition”. - Highlights: • A 2D to 3D transition has been detected for polymeric carbon nitride. • THz-TDS allowed us to discover and detect the 2D to 3D transition of polymeric carbon nitride. • We propose a structure for polymeric carbon nitride confirming it with THz-TDS.

  10. 2D to 3D transition of polymeric carbon nitride nanosheets

    International Nuclear Information System (INIS)

    Chamorro-Posada, Pedro; Vázquez-Cabo, José; Sánchez-Arévalo, Francisco M.; Martín-Ramos, Pablo; Martín-Gil, Jesús; Navas-Gracia, Luis M.; Dante, Roberto C.

    2014-01-01

    The transition from a prevalent turbostratic arrangement with low planar interactions (2D) to an array of polymeric carbon nitride nanosheets with stronger interplanar interactions (3D), occurring for samples treated above 650 °C, was detected by terahertz-time domain spectroscopy (THz-TDS). The simulated 3D material made of stacks of shifted quasi planar sheets composed of zigzagged polymer ribbons, delivered a XRD simulated pattern in relatively good agreement with the experimental one. The 2D to 3D transition was also supported by the simulation of THz-TDS spectra obtained from quantum chemistry calculations, in which the same broad bands around 2 THz and 1.5 THz were found for 2D and 3D arrays, respectively. This transition was also in accordance with the tightening of the interplanar distance probably due to an interplanar π bond contribution, as evidenced also by a broad absorption around 2.6 eV in the UV–vis spectrum, which appeared in the sample treated at 650 °C, and increased in the sample treated at 700 °C. The band gap was calculated for 1D and 2D cases. The value of 3.374 eV for the 2D case is, within the model accuracy and precision, in a relative good agreement with the value of 3.055 eV obtained from the experimental results. - Graphical abstract: 2D lattice mode vibrations and structural changes correlated with the so called “2D to 3D transition”. - Highlights: • A 2D to 3D transition has been detected for polymeric carbon nitride. • THz-TDS allowed us to discover and detect the 2D to 3D transition of polymeric carbon nitride. • We propose a structure for polymeric carbon nitride confirming it with THz-TDS

  11. The Future Is 3D

    Science.gov (United States)

    Carter, Luke

    2015-01-01

    3D printers are a way of producing a 3D model of an item from a digital file. The model builds up in successive layers of material placed by the printer controlled by the information in the computer file. In this article the author argues that 3D printers are one of the greatest technological advances of recent times. He discusses practical uses…

  12. 3D Digital Modelling

    DEFF Research Database (Denmark)

    Hundebøl, Jesper

    wave of new building information modelling tools demands further investigation, not least because of industry representatives' somewhat coarse parlance: Now the word is spreading -3D digital modelling is nothing less than a revolution, a shift of paradigm, a new alphabet... Research qeustions. Based...... on empirical probes (interviews, observations, written inscriptions) within the Danish construction industry this paper explores the organizational and managerial dynamics of 3D Digital Modelling. The paper intends to - Illustrate how the network of (non-)human actors engaged in the promotion (and arrest) of 3...... important to appreciate the analysis. Before turning to the presentation of preliminary findings and a discussion of 3D digital modelling, it begins, however, with an outline of industry specific ICT strategic issues. Paper type. Multi-site field study...

  13. A novel alternative method for 3D visualisation in Parasitology: the construction of a 3D model of a parasite from 2D illustrations.

    Science.gov (United States)

    Teo, B G; Sarinder, K K S; Lim, L H S

    2010-08-01

    Three-dimensional (3D) models of the marginal hooks, dorsal and ventral anchors, bars and haptoral reservoirs of a parasite, Sundatrema langkawiense Lim & Gibson, 2009 (Monogenea) were developed using the polygonal modelling method in Autodesk 3ds Max (Version 9) based on two-dimensional (2D) illustrations. Maxscripts were written to rotate the modelled 3D structures. Appropriately orientated 3D haptoral hard-parts were then selected and positioned within the transparent 3D outline of the haptor and grouped together to form a complete 3D haptoral entity. This technique is an inexpensive tool for constructing 3D models from 2D illustrations for 3D visualisation of the spatial relationships between the different structural parts within organisms.

  14. Calculation of null points in SPAIR, FLAIR, and STIR. Part 2. Application to pelvic diffusion-weighted imaging with SPAIR at 3T

    International Nuclear Information System (INIS)

    Kita, Miho; Kawano, Kazuhiro; Kometani, Katsuya; Kondo, Toshihiko; Shimamoto, Kazuhiro; Tanaka, Humihiro; Oda, Hideyuki; Kojima, Akihiro; Sato, Morio

    2013-01-01

    Diffusion-weighted imaging (DWI) requires adequate fat suppression because of its sensitivity to chemical shift artifacts, especially at 3 Tesla (T). We investigated the utility of calculating the inversion time of the null point (TI null ) in pelvic DWI with spectral attenuated inversion recovery (SPAIR) at 3 T for obtaining adequate fat suppression. Thirteen volunteers underwent pelvic SPAIR-DWI using various SPAIR inversion delay times (TI) at 5-ms intervals in the range of the calculated TI null ±25 ms. The degree of fat suppression was evaluated into 3 grades and was compared among the various SPAIR-TIs with the calculated TI null . In 65 cases of prostatic disease, we evaluated the ratio of adequate fat suppression obtained using the calculated TI null . We obtained adequate fat suppression in all 13 volunteers and in 61 (94%) of the 65 patients using the calculated TI null . Fat suppression was best when the calculated TI null was used (P null (P null increased. In conclusion, this method of calculating the TI null may be useful for obtaining adequate fat suppression for pelvic SPAIR-DWI at 3T. (author)

  15. Log-Based Recovery in Asynchronous Distributed Systems. Ph.D. Thesis

    Science.gov (United States)

    Kane, Kenneth Paul

    1989-01-01

    A log-based mechanism is described for restoring consistent states to replicated data objects after failures. Preserving a causal form of consistency based on the notion of virtual time is focused upon in this report. Causal consistency has been shown to apply to a variety of applications, including distributed simulation, task decomposition, and mail delivery systems. Several mechanisms have been proposed for implementing causally consistent recovery, most notably those of Strom and Yemini, and Johnson and Zwaenepoel. The mechanism proposed here differs from these in two major respects. First, a roll-forward style of recovery is implemented. A functioning process is never required to roll-back its state in order to achieve consistency with a recovering process. Second, the mechanism does not require any explicit information about the causal dependencies between updates. Instead, all necessary dependency information is inferred from the orders in which updates are logged by the object servers. This basic recovery technique appears to be applicable to forms of consistency other than causal consistency. In particular, it is shown how the recovery technique can be modified to support an atomic form of consistency (grouping consistency). By combining grouping consistency with casual consistency, it may even be possible to implement serializable consistency within this mechanism.

  16. View-based 3-D object retrieval

    CERN Document Server

    Gao, Yue

    2014-01-01

    Content-based 3-D object retrieval has attracted extensive attention recently and has applications in a variety of fields, such as, computer-aided design, tele-medicine,mobile multimedia, virtual reality, and entertainment. The development of efficient and effective content-based 3-D object retrieval techniques has enabled the use of fast 3-D reconstruction and model design. Recent technical progress, such as the development of camera technologies, has made it possible to capture the views of 3-D objects. As a result, view-based 3-D object retrieval has become an essential but challenging res

  17. 3D-Printed Millimeter Wave Structures

    Science.gov (United States)

    2016-03-14

    demonstrates the resolution of the printer with a 10 micron nozzle. Figure 2: Measured loss tangent of SEBS and SBS samples. 3D - Printed Millimeter... 3D printing of styrene-butadiene-styrene (SBS) and styrene ethylene/butylene-styrene (SEBS) is used to demonstrate the feasibility of 3D - printed ...Additionally, a dielectric lens is printed which improves the antenna gain of an open-ended WR-28 waveguide from 7 to 8.5 dBi. Keywords: 3D printing

  18. Materialedreven 3d digital formgivning

    DEFF Research Database (Denmark)

    Hansen, Flemming Tvede

    2010-01-01

    Formålet med forskningsprojektet er for det første at understøtte keramikeren i at arbejde eksperimenterende med digital formgivning, og for det andet at bidrage til en tværfaglig diskurs om brugen af digital formgivning. Forskningsprojektet fokuserer på 3d formgivning og derved på 3d digital...... formgivning og Rapid Prototyping (RP). RP er en fællesbetegnelse for en række af de teknikker, der muliggør at overføre den digitale form til 3d fysisk form. Forskningsprojektet koncentrerer sig om to overordnede forskningsspørgsmål. Det første handler om, hvordan viden og erfaring indenfor det keramiske...... fagområde kan blive udnyttet i forhold til 3d digital formgivning. Det andet handler om, hvad en sådan tilgang kan bidrage med, og hvordan den kan blive udnyttet i et dynamisk samspil med det keramiske materiale i formgivningen af 3d keramiske artefakter. Materialedreven formgivning er karakteriseret af en...

  19. The 3D LAOKOON--Visual and Verbal in 3D Online Learning Environments.

    Science.gov (United States)

    Liestol, Gunnar

    This paper reports on a project where three-dimensional (3D) online gaming environments were exploited for the purpose of academic communication and learning. 3D gaming environments are media and meaning rich and can provide inexpensive solutions for educational purposes. The experiment with teaching and discussions in this setting, however,…

  20. Sodium magnetic resonance imaging. Development of a 3D radial acquisition technique with optimized k-space sampling density and high SNR-efficiency; Natrium-Magnetresonanztomographie. Entwicklung einer 3D radialen Messtechnik mit optimierter k-Raum-Abtastdichte und hoher SNR-Effizienz

    Energy Technology Data Exchange (ETDEWEB)

    Nagel, Armin Michael

    2009-04-01

    A 3D radial k-space acquisition technique with homogenous distribution of the sampling density (DA-3D-RAD) is presented. This technique enables short echo times (TE<0.5 ms), that are necessary for {sup 23}Na-MRI, and provides a high SNR-efficiency. The gradients of the DA-3D-RAD-sequence are designed such that the average sampling density in each spherical shell of k-space is constant. The DA-3D-RAD-sequence provides 34% more SNR than a conventional 3D radial sequence (3D-RAD) if T{sub 2}{sup *}-decay is neglected. This SNR-gain is enhanced if T{sub 2}{sup *}-decay is present, so a 1.5 to 1.8 fold higher SNR is measured in brain tissue with the DA-3D-RAD-sequence. Simulations and experimental measurements show that the DA-3D-RAD sequence yields a better resolution in the presence of T{sub 2}{sup *}-decay and less image artefacts when B{sub 0}-inhomogeneities exist. Using the developed sequence, T{sub 1}-, T{sub 2}{sup *}- and Inversion-Recovery-{sup 23}Na-image contrasts were acquired for several organs and {sup 23}Na-relaxation times were measured (brain tissue: T{sub 1}=29.0{+-}0.3 ms; T{sub 2s}{sup *}{approx}4 ms; T{sub 2l}{sup *}{approx}31 ms; cerebrospinal fluid: T{sub 1}=58.1{+-}0.6 ms; T{sub 2}{sup *}=55{+-}3 ms (B{sub 0}=3 T)). T{sub 1}- und T{sub 2}{sup *}-relaxation times of cerebrospinal fluid are independent of the selected magnetic field strength (B0 = 3T/7 T), whereas the relaxation times of brain tissue increase with field strength. Furthermore, {sup 23}Na-signals of oedemata were suppressed in patients and thus signals from different tissue compartments were selectively measured. (orig.)