WorldWideScience

Sample records for reconstruction tendon interposition

  1. Tendon Interposition and Ligament Reconstruction with ECRL Tendon in the Late Stages of Kienböck’s Disease: A Cadaver Study

    Directory of Open Access Journals (Sweden)

    Nazım Karalezli

    2013-01-01

    Full Text Available Background. The optimal surgical treatment for Kienböck’s disease with stages IIIB and IV remains controversial. A cadaver study was carried out to evaluate the use of coiled extensor carpi radialis longus tendon for tendon interposition and a strip obtained from the same tendon for ligament reconstruction in the late stages of Kienböck’s disease. Methods. Coiled extensor carpi radialis longus tendon was used to fill the cavity of the excised lunate, and a strip obtained from this tendon was sutured onto itself after passing through the scaphoid and the triquetrum acting as a ligament to preserve proximal row integrity. Biomechanical tests were carried out in order to evaluate this new ligamentous reconstruction. Results. It was biomechanically confirmed that the procedure was effective against axial compression and distributed the upcoming mechanical stress to the distal row. Conclusion. Extensor carpi radialis longus tendon has not been used for tendon interposition and ligament reconstruction in the treatment of this disease before. In view of the biomechanical data, the procedure seems to be effective for the stabilization of scaphoid and carpal bones.

  2. Magnetic resonance imaging appearance of the flexor carpi radialis tendon after harvest in ligamentous reconstruction tendon interposition arthroplasty

    International Nuclear Information System (INIS)

    Beall, Douglas P.; Fish, Jon R.; Ritchie, Eric R.; Tran, Hoang N.; Ingari, John V.; Campbell, Scot E.; Grayson, David E.; Sanders, Timothy G.; Mundis, Gregory; Lehman, Thomas P.

    2006-01-01

    To determine whether the post-harvest magnetic resonance (MR) imaging appearance of flexor carpi radialis (FCR) tendons, harvested during ligamentous reconstruction tendon interposition (LRTI) of the thumb carpometacarpal (CMC) joint arthroplasty, is consistent with tendon regeneration. Operative reports and patient medical records for all patients undergoing LRTI arthroplasty between 1995 and 2003 at our institution were reviewed. MR images of the patients' forearms and wrists were obtained and interpreted by two musculoskeletal radiologists. Using the flexor carpi ulnaris (FCU) tendon as an internal standard, the extent of FCR tendon regeneration was expressed as a percentage by dividing the volume of regenerated FCR tendon by the volume of the FCU tendon. Fourteen patients who had the full thickness of the FCR tendon harvested and who were available for MR imaging were identified and included in the study. At least partial regeneration of the FCR tendon occurred in 11 of the 14 patients (79%). Of these, 2 patients (14%), demonstrated complete, or nearly complete regeneration. Partial regeneration of the FCR tendon was seen in 9 of the 14 patients (64%). In 3 patients (21%), there was no appreciable regeneration of the FCR tendon. Among patients who underwent full-thickness harvest of the FCR tendon for LRTI arthroplasty of the first CMC joint, the follow-up MR imaging appearance of the flexor carpi radialis tendon was consistent with tendon regeneration in 79% of those examined. (orig.)

  3. Effect of the Interposition of Calcium Phosphate Materials on Tendon-Bone Healing During Repair of Chronic Rotator Cuff Tear.

    Science.gov (United States)

    Zhao, Song; Peng, Lingjie; Xie, Guoming; Li, Dingfeng; Zhao, Jinzhong; Ning, Congqin

    2014-08-01

    The current nature of tendon-bone healing after rotator cuff (RC) repair is still the formation of granulation tissue at the tendon-bone interface rather than the formation of fibrocartilage, which is the crucial structure in native tendon insertion and can be observed after knee ligament reconstruction. The interposition of calcium phosphate materials has been found to be able to enhance tendon-bone healing in knee ligament reconstruction. However, whether the interposition of these kinds of materials can enhance tendon-bone healing or even change the current nature of tendon-bone healing after RC repair still needs to be explored. The interposition of calcium phosphate materials during RC repair would enhance tendon-bone healing or change its current nature of granulation tissue formation into a more favorable process. Controlled laboratory study. A total of 144 male Sprague-Dawley rats underwent unilateral detachment of the supraspinatus tendon, followed by delayed repair after 3 weeks. The animals were allocated into 1 of 3 groups: (1) repair alone, (2) repair with Ca5(PO4)2SiO4 (CPS) bioceramic interposition, or (3) repair with hydroxyapatite (HA) bioceramic interposition at the tendon-bone interface. Animals were sacrificed at 2, 4, or 8 weeks postoperatively, and microcomputed tomography (micro-CT) was used to quantify the new bone formation at the repair site. New fibrocartilage formation and collagen organization at the tendon-bone interface was evaluated by histomorphometric analysis. Biomechanical testing of the supraspinatus tendon-bone complex was performed. Statistical analysis was performed using 1-way analysis of variance. Significance was set at P repair, CPS bioceramic significantly increased the area of fibrocartilage at the tendon-bone interface compared with the control and HA groups. Moreover, CPS and HA bioceramics had significantly improved collagen organization. Biomechanical tests indicated that the CPS and HA groups have greater ultimate

  4. Stability of double-row rotator cuff repair is not adversely affected by scaffold interposition between tendon and bone.

    Science.gov (United States)

    Beitzel, Knut; Chowaniec, David M; McCarthy, Mary Beth; Cote, Mark P; Russell, Ryan P; Obopilwe, Elifho; Imhoff, Andreas B; Arciero, Robert A; Mazzocca, Augustus D

    2012-05-01

    Rotator cuff reconstructions may be improved by adding growth factors, cells, or other biologic factors into the repair zone. This usually requires a biological carrier (scaffold) to be integrated into the construct and placed in the area of tendon-to-bone healing. This needs to be done without affecting the constructs mechanics. Hypothesis/ The hypothesis was that scaffold placement, as an interposition, has no adverse effects on biomechanical properties of double-row rotator cuff repair. The purpose of this study was to examine the effect of scaffold interposition on the initial strength of rotator cuff repairs. Controlled laboratory study. Twenty-five fresh-frozen shoulders (mean age: 65.5 ± 8.9 years) were randomly assigned to 5 groups. Groups were chosen to represent a broad spectrum of commonly used scaffold types: (1) double-row repair without augmentation, (2) double-row repair with interposition of a fibrin clot (Viscogel), (3) double-row repair with interposition of a collagen scaffold (Mucograft) between tendon and bone, (4) double-row repair with interposition of human dermis patch (ArthroFlex) between tendon and bone, and (5) double-row repair with human dermis patch (ArthroFlex) placed on top of the repair. Cyclic loading to measure displacement was performed to 3000 cycles at 1 Hz with an applied 10- to 100-N load. The ultimate load to failure was determined at a rate of 31 mm/min. There were no significant differences in mean displacement under cyclic loading, slope, or energy absorbed to failure between all groups (P = .128, P = .981, P = .105). Ultimate load to failure of repairs that used the collagen patch as an interposition (573.3 ± 75.6 N) and a dermis patch on top of the reconstruction (575.8 ± 22.6 N) was higher compared with the repair without a scaffold (348.9 ± 98.8 N; P = .018 and P = .025). No significant differences were found for repairs with the fibrin clot as an interposition (426.9 ± 103.6 N) and the decellularized dermis

  5. Biomechanical comparison of expanded polytetrafluoroethylene (ePTFE) and PTFE interpositional patches and direct tendon-to-bone repair for massive rotator cuff tears in an ovine model.

    Science.gov (United States)

    McKeown, Andrew Dj; Beattie, Rebekah F; Murrell, George Ac; Lam, Patrick H

    2016-01-01

    Massive irreparable rotator cuff tears are a difficult problem. Modalities such as irrigation and debridement, partial repair, tendon transfer and grafts have been utilized with high failure rates and mixed results. Synthetic interpositional patch repairs are a novel and increasingly used approach. The present study aimed to examine the biomechanical properties of common synthetic materials for interpositional repairs in contrast to native tendon. Six ovine tendons, six polytetrafluoroethylene (PTFE) felt sections and six expanded PTFE (ePTFE) patch sections were pulled-to-failure to analyze their biomechanical and material properties. Six direct tendon-to-bone surgical method repairs, six interpositional PTFE felt patch repairs and six interpositional ePTFE patch repairs were also constructed in ovine shoulders and pulled-to-failure to examine the biomechanical properties of each repair construct. Ovine tendon had higher load-to-failure (591 N) and had greater stiffness (108 N/mm) than either PTFE felt (296 N, 28 N/mm) or ePTFE patch sections (323 N, 34 N/mm). Both PTFE felt and ePTFE repair techniques required greater load-to-failure (225 N and 177 N, respectively) than direct tendon-to-bone surgical repairs (147 N) in ovine models. Synthetic materials lacked several biomechanical properties, including strength and stiffness, compared to ovine tendon. Interpositional surgical repair models with these materials were significantly stronger than direct tendon-to-bone model repairs.

  6. Biology and augmentation of tendon-bone insertion repair

    Directory of Open Access Journals (Sweden)

    Lui PPY

    2010-08-01

    Full Text Available Abstract Surgical reattachment of tendon and bone such as in rotator cuff repair, patellar-patella tendon repair and anterior cruciate ligament (ACL reconstruction often fails due to the failure of regeneration of the specialized tissue ("enthesis" which connects tendon to bone. Tendon-to-bone healing taking place between inhomogenous tissues is a slow process compared to healing within homogenous tissue, such as tendon to tendon or bone to bone healing. Therefore special attention must be paid to augment tendon to bone insertion (TBI healing. Apart from surgical fixation, biological and biophysical interventions have been studied aiming at regeneration of TBI healing complex, especially the regeneration of interpositioned fibrocartilage and new bone at the healing junction. This paper described the biology and the factors influencing TBI healing using patella-patellar tendon (PPT healing and tendon graft to bone tunnel healing in ACL reconstruction as examples. Recent development in the improvement of TBI healing and directions for future studies were also reviewed and discussed.

  7. Quadriceps Tendon Autograft Medial Patellofemoral Ligament Reconstruction.

    Science.gov (United States)

    Fink, Christian; Steensen, Robert; Gföller, Peter; Lawton, Robert

    2018-06-01

    Critically evaluate the published literature related to quadriceps tendon (QT) medial patellofemoral ligament (MPFL) reconstruction. Hamstring tendon (HT) MPFL reconstruction techniques have been shown to successfully restore patella stability, but complications including patella fracture are reported. Quadriceps tendon (QT) reconstruction techniques with an intact graft pedicle on the patella side have the advantage that patella bone tunnel drilling and fixation are no longer needed, reducing risk of patella fracture. Several QT MPFL reconstruction techniques, including minimally invasive surgical (MIS) approaches, have been published with promising clinical results and fewer complications than with HT techniques. Parallel laboratory studies have shown macroscopic anatomy and biomechanical properties of QT are more similar to native MPFL than hamstring (HS) HT, suggesting QT may more accurately restore native joint kinematics. Quadriceps tendon MPFL reconstruction, via both open and MIS techniques, have promising clinical results and offer valuable alternatives to HS grafts for primary and revision MPFL reconstruction in both children and adults.

  8. Ipsilateral free semitendinosus tendon graft transfer for reconstruction of chronic tears of the Achilles tendon

    Directory of Open Access Journals (Sweden)

    Gougoulias Nikolaos

    2008-07-01

    Full Text Available Abstract Background Many techniques have been developed for the reconstruction of the Achilles tendon in chronic tears. In presence of a large gap (greater than 6 centimetres, tendon augmentation is required. Methods We present our method of minimally invasive semitendinosus reconstruction for the Achilles tendon using one para-midline and one midline incision. Results The first incision is a 5 cm longitudinal incision, made 2 cm proximal and just medial to the palpable end of the residual tendon. The second incision is 3 cm long and is also longitudinal but is 2 cm distal and in the midline to the distal end of the tendon rupture. The distal and proximal Achilles tendon stumps are mobilised. After trying to reduce the gap of the ruptured Achilles tendon, if the gap produced is greater than 6 cm despite maximal plantar flexion of the ankle and traction on the Achilles tendon stumps, the ipsilateral semitendinosus tendon is harvested. The semitendinosus tendon is passed through small incisions in the substance of the proximal stump of the Achilles tendon, and it is sutured to the Achilles tendon. It is then passed beneath the intact skin bridge into the distal incision, and passed from medial to lateral through a transverse tenotomy in the distal stump. With the ankle in maximal plantar flexion, the semitendinosus tendon is sutured to the Achilles tendon at each entry and exit point Conclusion This minimally invasive technique allows reconstruction of the Achilles tendon using the tendon of semitendinosus preserving skin integrity over the site most prone to wound breakdown, and can be especially used to reconstruct the Achilles tendon in the presence of large gap (greater than 6 centimetres.

  9. Interposition of Ileal J-Pouch for Rectum Reconstruction in Dog

    Directory of Open Access Journals (Sweden)

    Leila Ghahramani

    2014-03-01

    Full Text Available Background: The gold standard of the management of rectal cancer in the middle and lower parts is low anterior resection with coloanal anastomosis. About 50% of the patients undergoing this procedure might experience some complications because of the low capacity of the neorectum. The aim of this study was to evaluate ileal J-pouch interposition as a neorectum between the anal canal and the remaining colon in comparison to coloanal anastomosis and transverse coloplasty. Methods: Twelve dogs, weighing 23-27 kg, were divided into three groups. After laparotomy, the volume of the primary rectum was measured so that it could be compared with that of the neorectum at the end of the study. After rectal resection in Group A, the colon was directly anastomosed to the anus. In Group B, a 5-cm longitudinal incision was made 2 cm proximal to the anastomosis and was sutured transversely (coloplasty. In Group C, a 5-cm ileal J-pouch was interposed between the colon and anus. After 8 weeks, the neorectum was evaluated for volume, radiology, and pathology. Results: All the samples were alive until the end of the study. The healing of the anastomotic lines was acceptable (pathologically in all. The mean volume expansion was 20.9% in Group A, 21.7% in Group B, and 118.2% in Group C, with the latter being significantly higher than that of the other groups (P=0.03. Colon J-pouch and coloplasty after proctectomy in some situations have not been performable. This study evaluated the performance of ileal J-pouch interposition. Conclusion: This study showed that ileal J-pouch interposition might produce an acceptable reservoir function and that it seems feasible and safe in selected cases. Please cite this article as: Ghahramani L, Yazdani S, Derakhshani S, Rezaianzadeh A, Jalli R, Geramizadeh B, Safarpour AR, Rahimikazerooni S, Hosseini SV. Interposition of Ileal J-Pouch for Rectum Reconstruction in Dog. Iran J Med Sci. 2014;39(2:117-122.

  10. [Reconstruction of the extensor pollicis longus tendon by transposition of the extensor indicis tendon].

    Science.gov (United States)

    Loos, A; Kalb, K; Van Schoonhoven, J; Landsleitner Dagger, B

    2003-12-01

    Rupture of the extensor pollicis longus-tendon (EPL) is a frequent complication after distal radius fractures. Other traumatic and non-traumatic reasons for this tendon lesion are known, including a theory about a disorder in the blood supply to the tendon itself. We examined 40 patients after reconstruction of the EPL-tendon in a mean follow-up time of 30 months. All patients were clinically examined and a DASH questionnaire was answered by all patients. The method to reconstruct the EPL-tendon was the transposition of the extensor indicis-tendon. After the operations the thumb was put in a splint for four weeks in a "hitch-hiker's-position". 31 ruptures of the tendon (77.5 %) were a result of trauma. In 20 of them (50 %) a distal radius fracture had occurred. Clinical examination included measurements of the movement of the thumb- and index-finger joints, the grip strength and the maximal span of the hand. Significant differences were not found. The isolated extension of the index finger was possible in all patients. But it was reduced in ten cases which represent 25 %. Our results were evaluated by the Geldmacher score to evaluate the reconstruction of the EPL-tendon. 20 % excellent, 65 % good, 12.5 % fair and 2.5 % poor results were reached. The Geldmacher score was used critically. We suggest its modification for the evaluation of thumb abduction. The DASH score reached a functional value of ten points which represents a very good result. In conclusion the extensor indicis-transposition is a safe method to reconstruct the EPL-tendon. Its substantial advantage is taking a healthy muscle as the motor, thereby avoiding the risk of using a degenerated muscle in late tendon reconstruction. A powerful extension of the index finger will be maintained by physical education. Generally, the loss of the extension of the index finger is negligible. It does not disturb the patients. But it has to be discussed with the patient before the operation.

  11. Dysphagia after Colon Interposition Graft for Esophageal Carcinoma

    Directory of Open Access Journals (Sweden)

    C. Spitali

    2012-01-01

    Full Text Available Colon interposition is an established technique for esophageal reconstruction. We describe the case of primary adenocarcinoma arising in a colonic interposition graft that was performed after total esophagectomy for recurrence adenocarcinoma derived from the Barrett esophagus.

  12. Occult Interpositional Rotator Cuff - an Extremely Rare Case of Traumatic Rotator Cuff Tear

    Energy Technology Data Exchange (ETDEWEB)

    Su, Wei Ren; Jou, I Ming [National Cheng Kung University Hospital, Tainan (China); Lin, Cheng Li [Show-Chwan Memorial Hospital, Changhua (China); Chih, Wei Hsing [Chia-Yi Christian Hospital, Chiayi (China)

    2012-01-15

    Traumatic interposition of a rotator cuff tendon in the glenohumeral joint without recognizable glenohumeral dislocation is an unusual complication after shoulder trauma. Here we report the clinical and imaging presentations of a 17-year-old man with trapped rotator cuff tendons in the glenohumeral joint after a bicycle accident. The possible trauma mechanism is also discussed.

  13. Simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft.

    Science.gov (United States)

    Shin, Sang-Jin; Campbell, Sean; Scott, Jonathan; McGarry, Michelle H; Lee, Thay Q

    2014-09-01

    The purpose of this study was to introduce a novel surgical technique for simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft and to compare its biomechanical characteristics to those of a coracoid cerclage reconstruction of the coracoclavicular ligaments. Six matched pairs of human acromioclavicular joints with an average age of 54.8 ± 7.8 years were used. One shoulder from each pair received the single tendon acromioclavicular-coracoclavicular reconstruction; the contralateral shoulder received the coracoid cerclage reconstruction. Bovine extensor tendon was used for both techniques. The single tendon acromioclavicular-coracoclavicular reconstruction technique provided anatomic restoration of the two coracoclavicular ligaments and the superior and inferior acromioclavicular ligaments simultaneously using one coracoid hole, one acromion hole, and two clavicular holes with interference screws. Anterior-posterior and superior-inferior translations were quantified for all specimens before and after reconstruction, followed by load to failure testing. Following coracoid cerclage reconstruction, total anterior-posterior translation was significantly greater than intact (10.0 ± 5.7 mm; p = 0.008). Following single tendon acromioclavicular-coracoclavicular reconstruction, there was no significant difference in anterior-posterior translation compared to intact (-1.6 ± 2.2 mm; n.s.). The coracoid cerclage technique demonstrated significantly greater anterior-posterior translation than the single tendon acromioclavicular-coracoclavicular technique (p = 0.007). Both techniques restored superior-inferior translation to the intact condition (n.s.). Ultimate load, deformation at ultimate load, and energy absorbed at ultimate load were significantly greater after acromioclavicular-coracoclavicular reconstruction than after coracoid cerclage reconstruction (p

  14. Salvage reconstruction of failed interposition arthroplasty at the base of the thumb.

    Science.gov (United States)

    Braun, Richard M; Rechnic, Mark; Shah, Kalpit N

    2012-12-01

    We present an operative procedure designed to revise a failed arthroplasty at the base of the thumb. This report describes a reliable operation that corrects residual instability and malignment which results in thumbs that are weak and painful despite a previous procedure. The operation has also been used as a primary procedure for arthritis of the trapeziometacarpal joint where instability and subluxation was a major component of the problem requiring joint reconstruction. The unique features of this procedure include a reinforced double-thickness tendon graft, a unique tendon anchor, and a fascia lata allograft spacer. Significant functional improvement is anticipated when joint reconstruction provides increased proximal stability. Pinch and grip measurements improve. Pain scores also diminish after the operation. Hand function and patient satisfaction can be substantially improved with revision arthroplasty when the initial operation has failed to provide a thumb that is mobile, stable, and pain free. The technical features of the procedure address reduction of malignment, restoring of anatomic balance, and secure fixation of the proximal apex of the thumb metacarpal which restores thumb reduction position and digital balance.

  15. Hydroxyapatite-doped polycaprolactone nanofiber membrane improves tendon-bone interface healing for anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Han, Fei; Zhang, Peng; Sun, Yaying; Lin, Chao; Zhao, Peng; Chen, Jiwu

    2015-01-01

    Hamstring tendon autograft is a routine graft for anterior cruciate ligament (ACL) reconstruction. However, ways of improving the healing between the tendon and bone is often overlooked in clinical practice. This issue can be addressed by using a biomimetic scaffold. Herein, a biomimetic nanofiber membrane of polycaprolactone/nanohydroxyapatite/collagen (PCL/nHAp/Col) is fabricated that mimics the composition of native bone tissue for promoting tendon-bone healing. This membrane has good cytocompatibility, allowing for osteoblast cell adhesion and growth and bone formation. As a result, MC3T3 cells reveal a higher mineralization level in PCL/nHAp/Col membrane compared with PCL membrane alone. Further in vivo studies in ACL reconstruction in a rabbit model shows that PCL/nHAp/Col-wrapped tendon may afford superior tissue integration to nonwrapped tendon in the interface between the tendon and host bone as well as improved mechanical strength. This study shows that PCL/nHAp/Col nanofiber membrane wrapping of autologous tendon is effective for improving tendon healing with host bone in ACL reconstruction.

  16. Arthroscopic assisted tendon reconstruction for triangular fibrocartilage complex irreparable tears.

    Science.gov (United States)

    Luchetti, R; Atzei, A

    2017-05-01

    We report our 11-year experience of performing arthroscopically assisted triangular fibrocartilage complex reconstruction in the treatment of chronic distal radio-ulnar joint instability resulting from irreparable triangular fibrocartilage complex injuries. Eleven patients were treated. Three skin incisions were made in order to create radial and ulna tunnels for passage of the tendon graft, which is used to reconstruct the dorsal and palmar radio-ulnar ligaments, under fluoroscopic and arthroscopic guidance. At a mean follow-up of 68 months all but one had a stable distal radio-ulnar joint. Pain and grip strength, Mayo wrist score, Disability of the Arm Hand and Shoulder and patient-rated wrist and hand evaluation scores improved. The ranges of forearm rotation remained largely unchanged. Complications included an early tendon graft tear, two late-onset graft ruptures, one ulna styloid fracture during surgery and persistent wrist discomfort during forearm rotation requiring tendon graft revision in one case. An arthroscopic assisted approach for triangular fibrocartilage complex reconstruction appears safe and produces comparable results with the open technique. IV.

  17. Pain level after ACL reconstruction: A comparative study between free quadriceps tendon and hamstring tendons autografts.

    Science.gov (United States)

    Buescu, Cristian Tudor; Onutu, Adela Hilda; Lucaciu, Dan Osvald; Todor, Adrian

    2017-03-01

    The objective of this study was to compare the pain levels and analgesic consumption after single bundle ACL reconstruction with free quadriceps tendon autograft versus hamstring tendon autograft. A total of 48 patients scheduled for anatomic single-bundle ACL reconstruction were randomized into two groups: the free quadriceps tendon autograft group (24 patients) and the hamstring tendons autograft group (24 patients). A basic multimodal analgesic postoperative program was used for all patients and rescue analgesia was provided with tramadol, at pain scores over 30 on the Visual Analog Scale. The time to the first rescue analgesic, the number of doses of tramadol and pain scores were recorded. The results within the same group were compared with the Wilcoxon signed test. Supplementary analgesic drug administration proved significantly higher in the group of subjects with hamstring grafts, with a median (interquartile range) of 1 (1.3) dose, compared to the group of subjects treated with a quadriceps graft, median = 0.5 (0.1.25) (p = 0.009). A significantly higher number of subjects with a quadriceps graft did not require any supplementary analgesic drug (50%) as compared with subjects with hamstring graft (13%; Z-statistics = 3.01, p = 0.002). The percentage of subjects who required a supplementary analgesic drug was 38% higher in the HT group compared with the FQT group. The use of the free quadriceps tendon autograft for ACL reconstruction leads to less pain and analgesic consumption in the immediate postoperative period compared with the use of hamstrings autograft. Level I Therapeutic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  18. Reconstruction of medial patellofemoral ligament using quadriceps tendon combined with reconstruction of medial patellotibial ligament using patellar tendon: initial experience

    Directory of Open Access Journals (Sweden)

    Betina Bremer Hinckel

    2016-02-01

    Full Text Available ABSTRACT OBJECTIVE: To describe a surgical technique for anatomical reconstruction of the medial patellofemoral ligament using the quadriceps tendon, combined with reconstruction of the medial patellotibial ligament using the patellar tendon; and to present the initial results from a case series. METHOD: The proposed technique was used on a series of cases of patients with diagnoses of patellofemoral instability and indications for surgical treatment, who were attended by the Knee Group of HC-IOT, University of São Paulo. The following were evaluated before and after the operation: range of motion (ROM, apprehension test, lateral translation test, patellar inclination test, inverted J sign, subluxation upon extension, pain from compression of the patella and pain from contraction of the quadriceps. After the operation, the patients were asked whether any new episode of dislocation had occurred, what their degree of satisfaction with the surgery was (on a scale from 0 to 10 and whether they would be prepared to go through this operation again. RESULTS: Seven knees were operated, in seven patients, with a mean follow-up of 5.46 months (±2.07. Four patients who presented apprehension before the operation did not show this after the operation. The lateral translation test became normal for all the patients, while the patellar inclination test remained positive for two patients. The patients with an inverted J sign continued to be positive for this sign. Five patients were positive for subluxation upon extension before the operation, but all patients were negative for this after the operation. None of the patients presented any new episode of dislocation of the patella. All of them stated that they were satisfied: five gave a satisfaction score of 9 and two, a score of 10. All of them said that they would undergo the operation again. Only one patient presented a postoperative complication: dehiscence of the wound. CONCLUSION: Reconstruction of the

  19. Postoperative US of leg tendon reconstruction

    International Nuclear Information System (INIS)

    Draghi, F.; Calliada, F.; Fulle, I.; Madonia, L.; Bottinelli, O.; Campani, R.

    1999-01-01

    The role of ultrasound (US) in the postoperative assessment of tendon reconstruction is not clearly defined and there is non systematic arrangement of US patterns. The authors examined 34 patients submitted to surgery or conservative treatment for total/partial tear or musculotendinous detachment of patellar or Achilles tendon in the last 5 years. All patients underwent physical and US examinations. The surgical tendon exhibited the same US patterns in 23/28 patients: it was markedly enlarged (three-/fourfold the normal diameter) and more rounded, with inhomogeneous and hypoechoic appearance not only at the tear/surgical site but also above and below it, for some cm. Small hyperechoic images, mainly dots, were seen in 19 cases, which were referable to small calcifications and stitches. More and larger calcifications were found in 8 patients, where they were associated with anechoic degeneration areas. Color Doppler US showed moderate or strong hypervascularization around the tear in the first months post injury. US patterns did not correlate with physical findings, but color Doppler patterns did. In 6 cases of musculotendinous detachment submitted to conservative treatment, US showed enlargement and hypoechogenicity in the injury site only, with no involvement of the remaining tendon. US was also used to time and guide drainage of perilesional hematomas, which were often quite large. US is the method of choice in the postoperative follow-up of tendon tears and musculotendinous detachments because it shows abnormal signs which are missed at clinics and provides additional information needed for treatment planning [it

  20. Free Bone Plug Quadriceps Tendon Harvest and Suspensory Button Attachment for Anterior Cruciate Ligament Reconstruction.

    Science.gov (United States)

    Todor, Adrian; Caterev, Sergiu; Nistor, Dan Viorel; Khallouki, Youssef

    2016-06-01

    The most commonly used autografts for anterior cruciate ligament reconstruction are the bone-patellar tendon-bone and hamstring tendons. Each has its advantages and limitations. The bone-patellar tendon-bone autograft can lead to more donor-site morbidity, and the hamstring autograft can be unpredictable in size. The quadriceps tendon, with or without a bone block, has been described as an alternative graft source and has been used especially in revision cases, but in recent years, it has attracted attention even for primary cases. We report a technique for harvesting a free bone quadriceps tendon graft and attaching an extracortical button for femoral fixation for anterior cruciate ligament reconstruction.

  1. [Reconstruction of chronic Achilles tendon rupture with flexor hallucis longus tendon harvested using a minimally invasive technique].

    Science.gov (United States)

    Miao, Xudong; Wu, Yongping; Tao, Huimin; Yang, Disheng

    2011-07-01

    To evaluate the effectiveness of flexor hallucis longus tendon harvested using a minimally invasive technique in reconstruction of chronic Achilles tendon rupture. Between July 2006 and December 2009, 22 patients (22 feet) with chronic Achilles tendon rupture were treated, including 16 males and 6 females with a median age of 48 years (range, 28-65 years). The disease duration was 27-1,025 days (median, 51 days). Twenty-one patients had hooflike movement's history and 1 patient had no obvious inducement. The result of Thompson test was positive in 22 cases. The score was 53.04 +/- 6.75 according to American Orthopedic Foot and Ankle Society (AOFAS) ankle and hindfoot score system. MRI indicated that the gap of the chronic Achilles tendon rupture was 4.2-8.0 cm. A 3 cm-long incision was made vertically in the plantar aspect of the midfoot and a 1 cm-long transverse incision was made in a plantar flexor crease at the base of the great toe to harvest flexor hallucis longus tendon. The flexor hallucis longus tendon was 10.5-13.5 cm longer from tuber calcanei to the end of the Achilles tendon, and then the tendon was fixed to the tuber calcanei using interface screws or anchor nail after they were woven to form reflexed 3-bundle and sutured. Wound healed by first intention in all patients and no early complication occurred. Twenty-two patients were followed up 12-42 months (mean, 16.7 months). At 12 months after operation, The AOFAS ankle and hindfoot score was 92.98 +/- 5.72, showing significant difference when compared with that before operation (t= -40.903, P=0.000). The results were excellent in 18 cases, good in 2 cases, and fair in 2 cases with an excellent and good rate of 90.9%. No sural nerve injury, posterior tibial nerve injury, plantar painful scar, medial plantar nerve injury, and lateral plantar nerve injury occurred. Chronic Achilles tendon rupture reconstruction with flexor hallucis longus tendon harvested using a minimally invasive technique offers a

  2. Articular Cartilage Increases Transition Zone Regeneration in Bone-tendon Junction Healing

    Science.gov (United States)

    Qin, Ling; Lee, Kwong Man; Leung, Kwok Sui

    2008-01-01

    The fibrocartilage transition zone in the direct bone-tendon junction reduces stress concentration and protects the junction from failure. Unfortunately, bone-tendon junctions often heal without fibrocartilage transition zone regeneration. We hypothesized articular cartilage grafts could increase fibrocartilage transition zone regeneration. Using a goat partial patellectomy repair model, autologous articular cartilage was harvested from the excised distal third patella and interposed between the residual proximal two-thirds bone fragment and tendon during repair in 36 knees. We evaluated fibrocartilage transition zone regeneration, bone formation, and mechanical strength after repair at 6, 12, and 24 weeks and compared them with direct repair. Autologous articular cartilage interposition resulted in more fibrocartilage transition zone regeneration (69.10% ± 14.11% [mean ± standard deviation] versus 8.67% ± 7.01% at 24 weeks) than direct repair at all times. There was no difference in the amount of bone formation and mechanical strength achieved. Autologous articular cartilage interposition increases fibrocartilage transition zone regeneration in bone-tendon junction healing, but additional research is required to ascertain the mechanism of stimulation and to establish the clinical applicability. PMID:18987921

  3. Knee extension and flexion muscle power after anterior cruciate ligament reconstruction with patellar tendon graft or hamstring tendons graft: a cross-sectional comparison 3 years post surgery

    DEFF Research Database (Denmark)

    Ageberg, Eva; Roos, Harald; Silbernagel, Karin

    2008-01-01

    Hamstring muscles play a major role in knee-joint stabilization after anterior cruciate ligament (ACL) injury. Weakness of the knee extensors after ACL reconstruction with patellar tendon (PT) graft, and in the knee flexors after reconstruction with hamstring tendons (HT) graft has been observed ...

  4. Anatomic single-bundle anterior cruciate ligament reconstruction improves walking economy: hamstrings tendon versus patellar tendon grafts.

    Science.gov (United States)

    Iliopoulos, Efthymios; Galanis, Nikiforos; Zafeiridis, Andreas; Iosifidis, Michael; Papadopoulos, Pericles; Potoupnis, Michael; Geladas, Nikolaos; Vrabas, Ioannis S; Kirkos, John

    2017-10-01

    Anterior cruciate ligament (ACL) injury is associated with a pathologic gait pattern and increased energy cost during locomotion. ACL reconstruction could improve the gait pattern. Hamstrings tendon (HAM) and bone-patellar tendon-bone (BPTB) grafts are usually used for reconstruction. The aim of this study was to compare the efficacy of anatomic ACL reconstruction with HAM and BPTB grafts on improving and normalizing the energy cost and physiologic reserves during flat, uphill, and downhill walking. Twenty male subjects with unilateral ACL injuries were randomly assigned to ACL reconstruction with a HAM (n = 10) or BPTB (n = 10) graft. Ten matched controls were also enrolled. All participants performed three 8-min walking tasks at 0, +10, and -10 % gradients before and 9 months after surgery. Energy cost (oxygen consumption, VO 2 ), heart rate (HR), and ventilation (VE) were measured. Lysholm/IKDC scores were recorded. Pre-operatively, VO 2 , HR, and VE were higher in the HAM and BPTB groups than in controls during walking at 0, +10, and -10 % gradients (p energy cost and nearly normalized locomotion economy and cardiorespiratory reserves during flat, uphill, and downhill walking. The improved locomotion economy is an additional benefit of anatomic ACL reconstruction, irrespective of the type of graft used, that the orthopaedic surgeons should consider. II.

  5. [Isokinetic assessment with two years follow-up of anterior cruciate ligament reconstruction with patellar tendon or hamstring tendons].

    Science.gov (United States)

    Condouret, J; Cohn, J; Ferret, J-M; Lemonsu, A; Vasconcelos, W; Dejour, D; Potel, J-F

    2008-12-01

    This retrospective multicentric study was designed to assess the outcome of quadriceps and hamstrings muscles two years after Anterior Cruciate Ligament (ACL) reconstruction and compare muscles recovery depending on the type of graft and individual variables like age, gender, level of sport, but also in terms of discomfort, pain and functional score. The results focused on the subjective and objective IKDC scores, SF36, the existence or not of subjective disorders and their location. The review included isokinetic muscle tests concentric and eccentric extensors/flexors but also internal rotators/external rotators with analysis of mean work and mean power. One hundred and twenty-seven patients were included with an average age 29 years (+/-10). They all had an ACL reconstruction with patellar tendon or hamstring tendon with single or double bundles. In the serie, the average muscles deficit at two years was 10% for the flexors and extensors but with a significant dispersion. Significant differences were not noted in the mean values of all parameters in term of sex or age (over 30 years or not), neither the type of sport, nor of clinical assessment (Class A and B of objective IKDC score), nor the existence of anterior knee pain. There was a relationship between the level of extensor or flexor recovery and the quality of functional results with minimal muscle deficits close to 5% if the IKDC score was over 90 and deficits falling to 15% in the group with IKDC score less than 90. The type of reconstruction (patellar tendon versus hamstrings) had an influence on the muscle deficit. For extensors, the recovery was the same in the two groups, more than 90% at two years and the distribution of these two populations by level of deficit was quite the same. For flexors, residual deficits were significantly higher in the hamstrings group on the three studied parameters whatever the speed and the type of contraction (concentric or eccentric) with an average deficit of 14 to 18

  6. Estudo comparativo entre ressecção do trapézio e interposição tendinosa com e sem ligamentoplastia no tratamento da artrose carpometacarpiana do polegar Comparative study between trapezium resection and tendon interposition with and without ligament plasty in the management of carpometacarpal arthrosis of the thumb

    Directory of Open Access Journals (Sweden)

    Arlindo Gomes Pardini Junior

    2008-03-01

    opponency, movements of the metacarpophalangeal joint, pinching and pressure strength, radiographic measurement of the distance between the first metacarpian and the scaphoid, and measurement of the angle between the first and the second metacarpian. Subjective evaluation was done with a DASH questionnaire, an analogical-digital scale to evaluate pain and patient satisfaction. RESULTS AND CONCLUSION: After application of the criteria described and using Student t test for statistical analysis, the authors concluded that the ligament reconstruction has no advantage over the simple tendon interposition in carpometacarpal arthrosis of the thumb.

  7. Interposition of Ileal J-Pouch for Rectum Reconstruction in Dog

    Science.gov (United States)

    Ghahramani, Leila; Yazdani, Saeed; Derakhshani, Saeed; Rezaianzadeh, Abbas; Jalli, Reza; Geramizadeh, Bita; Safarpour, Ali Reza; Rahimikazerooni, Salar; Hosseini, Seyed Vahid

    2014-01-01

    Background: The gold standard of the management of rectal cancer in the middle and lower parts is low anterior resection with coloanal anastomosis. About 50% of the patients undergoing this procedure might experience some complications because of the low capacity of the neorectum. The aim of this study was to evaluate ileal J-pouch interposition as a neorectum between the anal canal and the remaining colon in comparison to coloanal anastomosis and transverse coloplasty. Methods: Twelve dogs, weighing 23-27 kg, were divided into three groups. After laparotomy, the volume of the primary rectum was measured so that it could be compared with that of the neorectum at the end of the study. After rectal resection in Group A, the colon was directly anastomosed to the anus. In Group B, a 5-cm longitudinal incision was made 2 cm proximal to the anastomosis and was sutured transversely (coloplasty). In Group C, a 5-cm ileal J-pouch was interposed between the colon and anus. After 8 weeks, the neorectum was evaluated for volume, radiology, and pathology. Results: All the samples were alive until the end of the study. The healing of the anastomotic lines was acceptable (pathologically) in all. The mean volume expansion was 20.9% in Group A, 21.7% in Group B, and 118.2% in Group C, with the latter being significantly higher than that of the other groups (P=0.03). Colon J-pouch and coloplasty after proctectomy in some situations have not been performable. This study evaluated the performance of ileal J-pouch interposition. Conclusion: This study showed that ileal J-pouch interposition might produce an acceptable reservoir function and that it seems feasible and safe in selected cases. PMID:24644380

  8. Interposition of ileal j-pouch for rectum reconstruction in dog.

    Science.gov (United States)

    Ghahramani, Leila; Yazdani, Saeed; Derakhshani, Saeed; Rezaianzadeh, Abbas; Jalli, Reza; Geramizadeh, Bita; Safarpour, Ali Reza; Rahimikazerooni, Salar; Hosseini, Seyed Vahid

    2014-03-01

    The gold standard of the management of rectal cancer in the middle and lower parts is low anterior resection with coloanal anastomosis. About 50% of the patients undergoing this procedure might experience some complications because of the low capacity of the neorectum. The aim of this study was to evaluate ileal J-pouch interposition as a neorectum between the anal canal and the remaining colon in comparison to coloanal anastomosis and transverse coloplasty. Twelve dogs, weighing 23-27 kg, were divided into three groups. After laparotomy, the volume of the primary rectum was measured so that it could be compared with that of the neorectum at the end of the study. After rectal resection in Group A, the colon was directly anastomosed to the anus. In Group B, a 5-cm longitudinal incision was made 2 cm proximal to the anastomosis and was sutured transversely (coloplasty). In Group C, a 5-cm ileal J-pouch was interposed between the colon and anus. After 8 weeks, the neorectum was evaluated for volume, radiology, and pathology. All the samples were alive until the end of the study. The healing of the anastomotic lines was acceptable (pathologically) in all. The mean volume expansion was 20.9% in Group A, 21.7% in Group B, and 118.2% in Group C, with the latter being significantly higher than that of the other groups (P=0.03). Colon J-pouch and coloplasty after proctectomy in some situations have not been performable. This study evaluated the performance of ileal J-pouch interposition. This study showed that ileal J-pouch interposition might produce an acceptable reservoir function and that it seems feasible and safe in selected cases.

  9. A mini-invasive adductor magnus tendon transfer technique for medial patellofemoral ligament reconstruction: a technical note.

    Science.gov (United States)

    Sillanpää, Petri J; Mäenpää, Heikki M; Mattila, Ville M; Visuri, Tuomo; Pihlajamäki, Harri

    2009-05-01

    Patellar dislocations are associated with injuries to the medial patellofemoral ligament (MPFL). Several techniques for MPFL reconstruction have been recently published with some disadvantages involved, including large skin incisions and donor site morbidity. Arthroscopic stabilizing techniques carry the potential of inadequate restoration of MPFL function. We present a minimally invasive technique for MPFL reconstruction using adductor magnus tendon autograft. This technique is easily performed, safe, and provides a stabilizing effect equal to current MPFL reconstructions. Skin incision of only 3-4 cm is located at the level of the proximal half of the patella. After identifying the distal insertion of the adductor magnus tendon, a tendon harvester is introduced to harvest the medial two-thirds of the tendon, while the distal insertion is left intact. The adductor magnus tendon is cut at 12-14 cm from its distal insertion and transferred into the patellar medial margin. Two suture anchors are inserted through the same incision at the superomedial aspect of the patella in the anatomic MPFL origin. The graft is tightened at 30 degrees knee flexion. Aftercare includes 4 weeks of brace treatment with restricted range of motion.

  10. Acromioclavicular joint reconstruction using a tendon graft: a biomechanical study comparing a novel “sutured throughout” tendon graft to a standard tendon graft

    Directory of Open Access Journals (Sweden)

    Naziri Qais

    2016-01-01

    Full Text Available Background: With a recurrence rate of over 30%, techniques that offer stronger acromioclavicular (AC joint reconstruction through increased graft strength may provide longevity. The purpose of our study was to determine the biomechanical strength of a novel tendon graft sutured throughout compared to a native tendon graft in Grade 3 anatomical AC joint reconstruction. Methods: For this in vitro experiment, nine paired (n = 18 embalmed cadaveric AC joints of three males and six females (age 86 years, range 51–94 years were harvested. Anatomic repair with fresh bovine Achilles tendon grafts without bone block was simulated. Specimens were divided into two groups; with group 1 using grafts with ultra-high molecular-weight polyethylene (UHMWPE suture ran throughout the entire length. In group 2, reconstruction with only native allografts was performed. The distal scapula and humerus were casted in epoxy compound and mounted on the mechanical testing machine. Tensile tests were performed using a mechanical testing machine at the rate of 50 mm/min. Maximum load and displacement to failure were collected. Results: The average load to failure was significantly higher for group 1 compared to group 2, with mean values of 437.5 N ± 160.7 N and 94.4 N ± 43.6 N, (p = 0.001. The average displacement to failure was not significantly different, with 29.7 mm ± 10.6 mm in group 1 and 25 mm ± 9.1 mm in group 2 (p = 0.25. Conclusion: We conclude that a UHMWPE suture reinforced graft can provide a 3.6 times stronger AC joint reconstruction compared to a native graft.

  11. Modified Weaver-Dunn Procedure Versus The Use of Semitendinosus Autogenous Tendon Graft for Acromioclavicular Joint Reconstruction.

    Science.gov (United States)

    Hegazy, Galal; Safwat, Hesham; Seddik, Mahmoud; Al-Shal, Ehab A; Al-Sebai, Ibrahim; Negm, Mohame

    2016-01-01

    The optimal operative method for acromioclavicular joint reconstruction remains controversial. The modified Weaver-Dunn method is one of the most popular methods. Anatomic reconstruction of coracoclavicular ligaments with autogenous tendon grafts, widely used in treating chronic acromioclavicular joint instability, reportedly diminishes pain, eliminates sequelae, and improves function as well as strength. To compare clinical and radiologic outcomes between a modified Weaver-Dunn procedure and an anatomic coracoclavicular ligaments reconstruction technique using autogenous semitendinosus tendon graft. Twenty patients (mean age, 39 years) with painful, chronic Rockwood type III acromioclavicular joint dislocations were subjected to surgical reconstruction. In ten patients, a modified Weaver-Dunn procedure was performed, in the other ten patients; autogenous semitendinosus tendon graft was used. The mean time between injury and the index procedure was 18 month (range from 9 - 28). Clinical evaluation was performed using the Oxford Shoulder Score and Nottingham Clavicle Score after a mean follow-up time of 27.8 months. Preoperative and postoperative radiographs were compared. In the Weaver-Dunn group the Oxford Shoulder Score improved from 25±4 to 40±2 points. While the Nottingham Clavicle Score increased from 48±7 to 84±11. In semitendinosus tendon graft group, the Oxford Shoulder Score improved from 25±3 points to 50±2 points and the Nottingham Clavicle Score from 48±8 points to 95±8, respectively. Acromioclavicular joint reconstruction using the semitendinosus tendon graft achieved better Oxford Shoulder Score and Nottingham Clavicle Score compared to the modified Weaver-Dunn procedure.

  12. Tendon 'turnover lengthening' technique.

    Science.gov (United States)

    Cerovac, S; Miranda, B H

    2013-11-01

    Tendon defect reconstruction is amongst the most technically challenging areas in hand surgery. Tendon substance deficiency reconstruction techniques include lengthening, grafting, two-stage reconstruction and tendon transfers, however each is associated with unique challenges over and above direct repair. We describe a novel 'turnover lengthening' technique for hand tendons that has successfully been applied to the repair of several cases, including a case of attritional flexor and traumatic extensor tendon rupture in two presented patients where primary tenorrhaphy was not possible. In both cases a good post-operative outcome was achieved, as the patients were happy having returned back to normal activities of daily living such that they were discharged 12 weeks post-operatively. Our technique avoids the additional morbidity and complications associated with grafting, transfers and two stage reconstructions. It is quick, simple and reproducible for defects not exceeding 3-4 cm, provides a means of immediate one stage reconstruction, no secondary donor site morbidity and does not compromise salvage by tendon transfer and/or two-stage reconstruction in cases of failure. To our knowledge no such technique has been previously been described to reconstruct such hand tendon defects. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  13. Anterior Cruciate Ligament Reconstruction using Bone Patellar Tendon Bone autograft in ACL deficient Knee

    Directory of Open Access Journals (Sweden)

    Navin Kumar Karn

    2015-12-01

    Full Text Available Background & Objectives: Injury to Anterior Cruciate Ligament (ACL reconstruction has increased because of increased interest in sports. There are various grafts used for reconstruction of ACL, for example, Bone Patellar Tendon Bone, Hamstring etc. The study was conducted to evaluate the results of Bone Patellar Tendon Bone graft used for reconstruction of Anterior Cruciate Ligament.Materials & Methods: 40 patients with chronic ACL deficient knee presenting to Neuro Hospital from July 2011 to June 2013 were included in the study. The patients with intraarticular fracture of knee, severe OA knee, local active or suspected infection and systemic disease that might influence the study results were excluded from the study. Bone patellar tendon bone graft was harvested from ipsilateral knee in all the cases. The patient was followed till 2 year with specified programme of rehabilitation. The pain was assessed using VAS and the function of the knee was assessed using Modified WOMAC knee index.Results: The long term satisfactory results in terms of functional stability, symptom relief and return to preinjury level of activity was seen in 32 cases (80%. Two knees got infected out of which one required arthroscopic debridement. Mean visual analogue scale was 8 and modified WOMAC knee score was 3 at 2 year follow up.Conclusion: Bone patellar tendon bone graft is useful in high demand patients and cost effective option with high patient satisfaction rate for reconstruction of ACL.JCMS Nepal. 2015;11(3:12-15.

  14. Quadriceps tendon autograft for arthroscopic knee ligament reconstruction: use it now, use it often.

    Science.gov (United States)

    Sheean, Andrew J; Musahl, Volker; Slone, Harris S; Xerogeanes, John W; Milinkovic, Danko; Fink, Christian; Hoser, Christian

    2018-04-28

    Traditional bone-patellar tendon-bone and hamstring tendon ACL grafts are not without limitations. A growing body of anatomic, biomechanical and clinical data has demonstrated the utility of quadriceps tendon autograft in arthroscopic knee ligament reconstruction. The quadriceps tendon autograft provides a robust volume of tissue that can be reliably harvested, mitigating the likelihood of variably sized grafts and obviating the necessity of allograft augmentation. Modern, minimally invasive harvest techniques offer the advantages of low rates of donor site morbidity and residual extensor mechanism strength deficits. New data suggest that quadriceps tendon autograft may possess superior biomechanical characteristics when compared with bone-patella tendon-bone (BPTB) autograft. However, there have been very few direct, prospective comparisons between the clinical outcomes associated with quadriceps tendon autograft and other autograft options (eg, hamstring tendon and bone-patellar tendon-bone). Nevertheless, quadriceps tendon autograft should be one of the primary options in any knee surgeon's armamentarium. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. [Arthroscopic double-row reconstruction of high-grade subscapularis tendon tears].

    Science.gov (United States)

    Plachel, F; Pauly, S; Moroder, P; Scheibel, M

    2018-04-01

    Reconstruction of tendon integrity to maintain glenohumeral joint centration and hence to restore shoulder functional range of motion and to reduce pain. Isolated or combined full-thickness subscapularis tendon tears (≥upper two-thirds of the tendon) without both substantial soft tissue degeneration and cranialization of the humeral head. Chronic tears of the subscapularis tendon with higher grade muscle atrophy, fatty infiltration, and static decentration of the humeral head. After arthroscopic three-sided subscapularis tendon release, two double-loaded suture anchors are placed medially to the humeral footprint. Next to the suture passage, the suture limbs are tied and secured laterally with up to two knotless anchors creating a transosseous-equivalent repair. The affected arm is placed in a shoulder brace with 20° of abduction and slight internal rotation for 6 weeks postoperatively. Rehabilitation protocol including progressive physical therapy from a maximum protection phase to a minimum protection phase is required. Overhead activities are permitted after 6 months. While previous studies have demonstrated superior biomechanical properties and clinical results after double-row compared to single-row and transosseous fixation techniques, further mid- to long-term clinical investigations are needed to confirm these findings.

  16. A RETROSPECTIVE ANALYSIS OF ARTHROSCOPIC ACL RECONSTRUCTION WITH HAMSTRING TENDON GRAFT

    Directory of Open Access Journals (Sweden)

    Ashish R. Agarwal

    2017-08-01

    Full Text Available BACKGROUND ACL reconstruction is one of the commonest knee surgeries done. Young adults are the commonest patients; thus, this injury has a large impact on socioeconomic status of the family. The aim of the study is to study the outcome of arthroscopic ACL reconstruction with hamstring tendon graft. MATERIALS AND METHODS 50 patients following up in the OPD who had undergone ACL reconstruction with hamstring tendon graft are evaluated. Patients who had other lesions, such meniscal injuries or collateral injuries were discarded. These patients were evaluated by using Tegner and Lysholm score of 6 months, 12 months and 24 months. Settings- It is a retrospective analysis of the data collected from the patients who were opiated at Nair Hospital. RESULTS 90% of patients in the study were males. Mean age of the study population is 30.7 years. All the patients in the study had instability as a symptom, while 80% of them also had pain. Six months after surgery, according to Tegner and Lysholm score, 52% patients had good outcome, while 48% had fair outcome. At 2 years, 98% of study population had excellent outcome. CONCLUSION Arthroscopic ACL reconstruction with hamstring graft is an effective way of treating ACL tear.

  17. Three-Dimensional Bio-Printed Scaffold Sleeves With Mesenchymal Stem Cells for Enhancement of Tendon-to-Bone Healing in Anterior Cruciate Ligament Reconstruction Using Soft-Tissue Tendon Graft.

    Science.gov (United States)

    Park, Sin Hyung; Choi, Yeong-Jin; Moon, Sang Won; Lee, Byung Hoon; Shim, Jin-Hyung; Cho, Dong-Woo; Wang, Joon Ho

    2018-01-01

    To investigate the efficacy of the insertion of 3-dimensional (3D) bio-printed scaffold sleeves seeded with mesenchymal stem cells (MSCs) to enhance osteointegration between the tendon and tunnel bone in anterior cruciate ligament (ACL) reconstruction in a rabbit model. Scaffold sleeves were fabricated by 3D bio-printing. Before ACL reconstruction, MSCs were seeded into the scaffold sleeves. ACL reconstruction with hamstring tendon was performed on both legs of 15 adult rabbits (aged 12 weeks). We implanted 15 bone tunnels with scaffold sleeves with MSCs and implanted another 15 bone tunnels with scaffold sleeves without MSCs before passing the graft. The specimens were harvested at 4, 8, and 12 weeks. H&E staining, immunohistochemical staining of type II collagen, and micro-computed tomography of the tunnel cross-sectional area were evaluated. Histologic assessment was conducted with a histologic scoring system. In the histologic assessment, a smooth bone-to-tendon transition through broad fibrocartilage formation was identified in the treatment group, and the interface zone showed abundant type II collagen production on immunohistochemical staining. Bone-tendon healing histologic scores were significantly higher in the treatment group than in the control group at all time points. Micro-computed tomography at 12 weeks showed smaller tibial (control, 9.4 ± 0.9 mm 2 ; treatment, 5.8 ± 2.9 mm 2 ; P = .044) and femoral (control, 9.6 ± 2.9 mm 2 ; treatment, 6.0 ± 1.0 mm 2 ; P = .03) bone-tunnel areas in the treated group than in the control group. The 3D bio-printed scaffold sleeve with MSCs exhibited excellent results in osteointegration enhancement between the tendon and tunnel bone in ACL reconstruction in a rabbit model. If secure biological healing between the tendon graft and tunnel bone can be induced in the early postoperative period, earlier, more successful rehabilitation may be facilitated. Three-dimensional bio-printed scaffold sleeves with

  18. Reconstruction of long digital extensor tendon by cranial tibial muscle fascia graft in a dog.

    Science.gov (United States)

    Sabiza, Soroush; Khajeh, Ahmad; Naddaf, Hadi

    2016-01-01

    Tendon rupture in dogs is generally the result of a direct trauma. This report described the use of adjacent muscle autogenic fascial graft for reconstruction of distal rupture of long digital extensor tendon in a dog. A two-year-old male mix breed dog, was presented with a non-weight bearing lameness of the right hind limb and a deep rupture of lateral side of right tarsus. History taking revealed that this rupture appeared without any apparent cause, when walking around the farm, three days before. Radiography was done and no fracture was observed. Hyperextension of right tarsal joint compared to left limb was observed. Under general anesthesia, after dissections of the ruptured area, complete rupture of long digital extensor tendon was revealed. Then, we attempted to locate the edge of the tendon, however, the tendon length was shortened approximately 1 cm. Hence, a strip of 1 cm length from fascia of cranial tibial muscle was harvested to fill the defect. The graft was sutured to the two ends of tendon using locking loop pattern. Subcutaneous layers and the skin were sutured routinely. Ehmer sling bandage was applied to prevent weight bearing on the surgical region. Re-examination and phone contact with the owner eight weeks and six months postoperatively revealed a poor lameness and excellent function of the dog, respectively. It could be concluded that the fascia of adjacent muscles can be used as an autogenic graft for reconstruction of some tendon ruptures.

  19. Mechanical Loading Improves Tendon-Bone Healing in a Rabbit Anterior Cruciate Ligament Reconstruction Model by Promoting Proliferation and Matrix Formation of Mesenchymal Stem Cells and Tendon Cells

    Directory of Open Access Journals (Sweden)

    Fanglong Song

    2017-02-01

    Full Text Available Background/Aims: This study investigated the effect of mechanical stress on tendon-bone healing in a rabbit anterior cruciate ligament (ACL reconstruction model as well as cell proliferation and matrix formation in co-culture of bone-marrow mesenchymal stem cells (BMSCs and tendon cells (TCs. Methods: The effect of continuous passive motion (CPM therapy on tendon-bone healing in a rabbit ACL reconstruction model was evaluated by histological analysis, biomechanical testing and gene expressions at the tendon-bone interface. Furthermore, the effect of mechanical stretch on cell proliferation and matrix synthesis in BMSC/TC co-culture was also examined. Results: Postoperative CPM therapy significantly enhanced tendon-bone healing, as evidenced by increased amount of fibrocartilage, elevated ultimate load to failure levels, and up-regulated gene expressions of Collagen I, alkaline phosphatase, osteopontin, Tenascin C and tenomodulin at the tendon-bone junction. In addition, BMSC/TC co-culture treated with mechanical stretch showed a higher rate of cell proliferation and enhanced expressions of Collagen I, Collagen III, alkaline phosphatase, osteopontin, Tenascin C and tenomodulin than that of controls. Conclusion: These results demonstrated that proliferation and differentiation of local precursor cells could be enhanced by mechanical stimulation, which results in enhanced regenerative potential of BMSCs and TCs in tendon-bone healing.

  20. Do peak torque angles of muscles change following anterior cruciate ligament reconstruction using hamstring or patellar tendon graft?

    Science.gov (United States)

    Yosmaoğlu, Hayri Baran; Baltacı, Gül; Sönmezer, Emel; Özer, Hamza; Doğan, Deha

    2017-12-01

    This study aims to compare the effects of anterior cruciate ligament (ACL) reconstruction using autogenous hamstring or patellar tendon graft on the peak torque angle. The study included 132 patients (103 males, 29 females; mean age 29±9 year) who were performed ACL reconstruction with autogenous hamstring or patellar tendon graft. The peak torque angles in the quadriceps and hamstring muscles were recorded using an isokinetic dynamometer. Angle of peak knee flexion torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the hamstring tendon group. Angle of peak knee extension torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the patellar tendon group. There were no statistically significant differences in the flexion and extension peak torque angles between the operated and nonoperated knees at 60°/second in both groups. The angle of peak torque at relatively high angular velocities is affected after ACL reconstruction in patients with hamstring or patellar tendon grafts. The graft donor site directly influences this parameter. This finding may be important for clinicians in terms of preventing re-injury.

  1. Interposition of Ileal J-Pouch for Rectum Reconstruction in Dog

    OpenAIRE

    Leila Ghahramani; Saeed Yazdani; Saeed Derakhshani; Abbas Rezaianzadeh; Reza Jalli; Bita Geramizadeh; Ali Reza Safarpour; Salar Rahimikazerooni; Seyed Vahid Hosseini

    2014-01-01

    Background: The gold standard of the management of rectal cancer in the middle and lower parts is low anterior resection with coloanal anastomosis. About 50% of the patients undergoing this procedure might experience some complications because of the low capacity of the neorectum. The aim of this study was to evaluate ileal J-pouch interposition as a neorectum between the anal canal and the remaining colon in comparison to coloanal anastomosis and transverse coloplasty. Methods: Twelve do...

  2. Interposition vein cuffs.

    Science.gov (United States)

    Harris, P; Da Silva, T; How, T

    1996-01-01

    A vein cuff interposed at the distal anastomosis between a prosthetic vascular graft and a recipient infrageniculate artery improves the chances of continued patency of the graft, at least in the short and medium term. The mode of effect appears to be suppression or modification of anastomotic myointimal hyperplasia (MIH). In the event of graft failure the recipient artery and run-off vessels remain free from MIH and their patency is preserved thereby improving the prospects for further vascular reconstruction and limb salvage. The mechanisms by which interposition vein cuffs might modulate MIH are reviewed. Experimental evidence is described to show that the geometry of a cuffed anastomosis promotes a characteristic haemodynamic flow structure with a stable vortex. It is suggested that this vortex exerts greater shear stress upon the wall of the artery than the normal laminar flow observed in conventional anastomoses. High shear stress is known to inhibit MIH.

  3. Firm anchoring between a calcium phosphate-hybridized tendon and bone for anterior cruciate ligament reconstruction in a goat model

    Energy Technology Data Exchange (ETDEWEB)

    Mutsuzaki, Hirotaka [Department of Orthopaedic Surgery, Ibaraki Prefectural University of Health Sciences, 4669-2 Ami Ami-machi, Inashiki-gun, Ibaraki 300-0394 (Japan); Sakane, Masataka; Ochiai, Naoyuki [Department of Orthopaedic Surgery, Institute of Clinical Medicine, Graduate School of Comprehensive Human Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 (Japan); Hattori, Shinya; Kobayashi, Hisatoshi, E-mail: sakane-m@md.tsukuba.ac.j [Biomaterial Center, National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan)

    2009-08-15

    Using an alternative soaking process improved the tendon-bone attachment for a calcium phosphate (CaP)-hybridized tendon graft. We characterized the deposited CaP on and in tendons and analyzed the histology and mechanical properties of the tendon-bone interface in anterior cruciate ligament (ACL) reconstruction in goats. The tendon grafts to be implanted were soaked ten times alternately in a Ca-containing solution and a PO{sub 4}-containing solution for 30 s each. Needlelike CaP nanocrystals including low-crystalline apatite were deposited on and between collagen fibrils from the surface to a depth of 200{mu}m inside the tendon. The structure resembles the extracellular matrix of bone. In animal experiments, the CaP-hybridized tendon directly bonded with newly formed bone at 6 weeks (n = 3), while fibrous bonding was observed in the control (n = 3). The ultimate failure load was not statistically different between the CaP (n = 7) and control (n = 7). However, in the failure mode, all the tendon-bone interfaces were intact in the CaP group, while three of seven specimens were pulled out from bone tunnels in the control. The result suggested that the strength of the tendon-bone interface in the CaP group is superior to that in the control group. Clinically, firm tendon-bone anchoring may lead to good results without the knee instability associated with the loosening of the bone-tendon junction in ACL reconstruction.

  4. Abductor pollicis longus tendon interposition for arthrosis of the first carpo-metacarpal joint. Long-term results.

    Science.gov (United States)

    Lied, Line; Bjørnstad, Kari; Woje, Ann K N; Finsen, Vilhjalmur

    2016-02-01

    We performed an interposition arthroplasty using the abductor pollicis longus tendon for arthrosis in the basal joint of the thumb that needed surgery from 1995 to 2010. In 2001 47 patients (55 thumbs) were reviewed after 3.5 (1-5) years. The pain relief was excellent in 32 thumbs, and 25 patients improved their ability to perform daily tasks. Mobility was well preserved. Key pinch and grip strengths averaged 78% and 89%, respectively, of those in unaffected hands. We have now re-examined all 33 available patients (36 thumbs) 11-14 years after surgery. Fourty one of the originally examined patients were still alive. Seven were too ill to attend a follow-up and one refused. The remainder were examined in a fashion as similar as possible to that at the original review. The patients' subjective estimations of pain during the last week and satisfaction with the cosmetic and general results were recorded on visual analogue scales. The patients' ability to perform various activities of daily living were recorded and they completed the Disability of the arm, shoulder and hand (DASH) questionnaire. The mobility of the wrist and abduction of the thumb of the operated hands were recorded with a goniometer. Grip and pinch strength were measured and new radiographs were obtained. Key pinch strength had increased significantly over the last 10 years. The mobility was still good, except for thumb abduction, which had decreased with time. The median DASH score had fallen from 28 to 20 between the two reviews. There was insignificant further median loss of distance between the scaphoid and the metacarpal since the earlier review. The good results of this procedure found soon after surgery are maintained long-term.

  5. Quadriceps Tendon Autograft in Anterior Cruciate Ligament Reconstruction: A Systematic Review.

    Science.gov (United States)

    Hurley, Eoghan T; Calvo-Gurry, Manuel; Withers, Dan; Farrington, Shane K; Moran, Ray; Moran, Cathal J

    2018-05-01

    To systematically review the current evidence to ascertain whether quadriceps tendon autograft (QT) is a viable option in anterior cruciate ligament reconstruction. A literature review was conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Cohort studies comparing QT with bone-patellar tendon-bone autograft (BPTB) or hamstring tendon autograft (HT) were included. Clinical outcomes were compared, with all statistical analyses performed using IBM SPSS Statistics for Windows, version 22.0, with P < .05 being considered statistically significant. We identified 15 clinical trials with 1,910 patients. In all included studies, QT resulted in lower rates of anterior knee pain than BPTB. There was no difference in the rate of graft rupture between QT and BPTB or HT in any of the studies reporting this. One study found that QT resulted in greater knee stability than BPTB, and another study found increased stability compared with HT. One study found that QT resulted in improved functional outcomes compared with BPTB, and another found improved outcomes compared with HT, but one study found worse outcomes compared with BPTB. Current literature suggests QT is a viable option in anterior cruciate ligament reconstruction, with published literature showing comparable knee stability, functional outcomes, donor-site morbidity, and rerupture rates compared with BPTB and HT. Level III, systematic review of Level I, II, and III studies. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  6. An Isolated Medial Patellofemoral Ligament Reconstruction with Patellar Tendon Autograft

    Directory of Open Access Journals (Sweden)

    Dariusz Witoński

    2013-01-01

    Full Text Available The aim of the study was to evaluate the results of the medial patellofemoral ligament reconstruction with a medial strip of patellar tendon autograft after a minimum 2-year followup. Ten patients (10 knees were operated on by one surgeon, according to the modified technique, described by Camanho, without any bone plug at free graft end. The mean age of the patients was 27.2 years (ranging from 18 to 42 years. The mean follow-up period was 3 years and 7 months. All patients were reviewed prospectively. At the last follow-up visit, all the patients demonstrated a significant improvement in terms of patellofemoral joint stability, all aspects of the KOOS questionnaire, and Kujala et al.’s score (59.7 points preoperatively and 84.4 points at the last followup. No patient revealed recurrent dislocation. The SF-36 score revealed a significant improvement in bodily pain, general health, physical role functioning, social role functioning, and physical functioning domains. The described MPFL reconstruction with the use of the medial 1/3rd of patella tendon is an effective procedure that gives satisfactorily patellofemoral joint functions, improves the quality of life, and provides much pain relief. It is relatively simple, surgically not extensive, and economically cost-effective procedure.

  7. Hypoglossal-facial-jump-anastomosis without an interposition nerve graft.

    Science.gov (United States)

    Beutner, Dirk; Luers, Jan C; Grosheva, Maria

    2013-10-01

    The hypoglossal-facial-anastomosis is the most often applied procedure for the reanimation of a long lasting peripheral facial nerve paralysis. The use of an interposition graft and its end-to-side anastomosis to the hypoglossal nerve allows the preservation of the tongue function and also requires two anastomosis sites and a free second donor nerve. We describe the modified technique of the hypoglossal-facial-jump-anastomosis without an interposition and present the first results. Retrospective case study. We performed the facial nerve reconstruction in five patients. The indication for the surgery was a long-standing facial paralysis with preserved portion distal to geniculate ganglion, absent voluntary activity in the needle facial electromyography, and an intact bilateral hypoglossal nerve. Following mastoidectomy, the facial nerve was mobilized in the fallopian canal down to its bifurcation in the parotid gland and cut in its tympanic portion distal to the lesion. Then, a tensionless end-to-side suture to the hypoglossal nerve was performed. The facial function was monitored up to 16 months postoperatively. The reconstruction technique succeeded in all patients: The facial function improved within the average time period of 10 months to the House-Brackmann score 3. This modified technique of the hypoglossal-facial reanimation is a valid method with good clinical results, especially in cases of a preserved intramastoidal facial nerve. Level 4. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  8. Acromioclavicular Reconstruction using Autogenous Semitendinosus Tendon Graft and the Importance of Postoperative Rehabilitation: A Case Report

    Directory of Open Access Journals (Sweden)

    Jade PY Ho

    2013-11-01

    Full Text Available We present a case of chronic acromioclavicular joint dislocation (Rockwood type 5 in which the choice of acromioclavicular reconstruction using autogenous semitendinosus tendon graft was made due to its superiority in anatomical reconstruction of the coracoclavicular ligaments, and the impact of postoperative rehabilitation on the recovery of this patient. We also discuss the rationale behind this.

  9. Long-term comparison of boomerang-shaped jejunal interposition and Billroth-I reconstruction after distal gastrectomy.

    Science.gov (United States)

    Sasaki, Kinro; Miyachi, Kazuhito; Yoda, Norihito; Onodera, Shinichi; Satomura, Hitoshi; Otsuka, Kichiro; Nakajima, Masanobu; Yamaguchi, Satoru; Sunagawa, Masakatsu; Kato, Hiroyuki

    2015-05-01

    Billroth-I (BI) is a simple, physiological method of reconstruction following distal gastrectomy. In actuality, postoperative QOL is by no means favorable due to the high incidence of post-gastrectomy syndrome. The aim of this study is to assess the safety and efficacy of boomerang-shaped jejunal interposition (BJI) after distal gastrectomy. Sixty-six patients with early gastric cancer underwent the BI procedure (n = 33) or BJI (n = 33) after distal gastrectomy, following which they were compared for 5 years. Tumor characteristics, operative details, postoperative complications and complaints, number of meals, and body weight were analyzed. Patients were followed up by endoscopy every 12 months. There were no significant differences in the incidence of postoperative complications. The incidence of heartburn (30 vs. 0 %, P = 0.0009) and oral bitterness (33 vs. 6 %, P = 0.0112) were significantly lower in the BJI cases. Endoscopic findings revealed significantly lower incidences of reflux esophagitis (24 vs. 0 %, P = 0.0051) and remnant gastritis (70 vs. 3 %, P < 0.0001) in the BJI group. The incidence of food stasis was low in both groups (12 vs. 15 %). In the BJI group, 30 patients (90 %) were eating 3 meals/day within 12 months, whereas in the BI group, 16 patients (48 %) were still eating 5 meals/day at 12 months or later. BJI is as safe as BI, but is better in terms of improvement in bile reflux and food intake without stasis. This procedure, therefore, appears to be a useful method for reconstruction after distal gastrectomy.

  10. Clinical and radiological outcomes after a quasi-anatomical reconstruction of medial patellofemoral ligament with gracilis tendon autograft.

    Science.gov (United States)

    Monllau, Joan C; Masferrer-Pino, Àngel; Ginovart, Gerard; Pérez-Prieto, Daniel; Gelber, Pablo E; Sanchis-Alfonso, Vicente

    2017-08-01

    To analyse the clinical and radiological outcomes of a quasi-anatomical reconstruction of the medial patellofemoral ligament (MPFL) with a gracilis tendon autograft. Patients with objective recurrent patellar instability that were operated on from 2006 to 2012 were included. A quasi-anatomical surgical technique was performed using a gracilis tendon autograft. It was anatomically attached at the patella, and the adductor magnus tendon was also used as a pulley for femoral fixation (non-anatomical reconstruction). The IKDC, Kujala and Lysholm scores as well as Tegner and VAS for pain were collected preoperatively and at final follow-up. Radiographic measurements of patellar position tilt and signs of osteoarthritis (OA) as well as trochlear dysplasia were also recorded. Thirty-six patients were included. The mean age at surgery was 25.6 years. After a minimum 27 months of follow-up, all functional scores significantly improved (p patellofemoral surfaces at the short term, as shown by the absence of radiological signs of OA in the CT scan. The procedure has been shown to be safe and suitable for the treatment of chronic patellar instability, including in adolescents with open physis. A new effective, inexpensive and easy-to-perform technique is described to reconstruct MPFL in the daily clinical practice. Therapeutic case series, Level IV.

  11. Synthetic Augmented Suture Anchor Reconstruction for a Complete Traumatic Distal Triceps Tendon Rupture in a Male Professional Bodybuilder with Postoperative Biomechanical Assessment

    Directory of Open Access Journals (Sweden)

    Maria-Elissavet Nikolaidou

    2014-01-01

    Full Text Available Bodybuilding is a high-risk sport for distal triceps tendon ruptures. Management, especially in high-demanding athletes, is operative with suture anchor refixation technique being frequently used. However, the rate of rerupture is high due to underlying poor tendon quality. Thus, additional augmentation could be useful. This case report presents a reconstruction technique for a complete traumatic distal triceps tendon rupture in a bodybuilder with postoperative biomechanical assessment. A 28-year-old male professional bodybuilder was treated with a synthetic augmented suture anchor reconstruction for a complete triceps tendon rupture of his right dominant elbow. Postoperative biomechanical assessment included isokinetic elbow strength and endurance testing by using multiple angular velocities to simulate the “off-season” and “precompetition” phases of training. Eighteen months postoperatively and after full return to training, the biomechanical assessment indicated that the strength and endurance of the operated elbow joint was fully restored with even higher ratings compared to the contralateral healthy arm. The described reconstruction technique can be considered as an advisable option in high-performance athletes with underlying poor tendon quality due to high tensile strength and lack of donor site morbidity, thus enabling them to restore preinjury status and achieve safe return to sports.

  12. Synthetic Augmented Suture Anchor Reconstruction for a Complete Traumatic Distal Triceps Tendon Rupture in a Male Professional Bodybuilder with Postoperative Biomechanical Assessment

    Science.gov (United States)

    Nikolaidou, Maria-Elissavet; Banke, Ingo J.; Laios, Thomas; Petsogiannis, Konstantinos; Mourikis, Anastasios

    2014-01-01

    Bodybuilding is a high-risk sport for distal triceps tendon ruptures. Management, especially in high-demanding athletes, is operative with suture anchor refixation technique being frequently used. However, the rate of rerupture is high due to underlying poor tendon quality. Thus, additional augmentation could be useful. This case report presents a reconstruction technique for a complete traumatic distal triceps tendon rupture in a bodybuilder with postoperative biomechanical assessment. A 28-year-old male professional bodybuilder was treated with a synthetic augmented suture anchor reconstruction for a complete triceps tendon rupture of his right dominant elbow. Postoperative biomechanical assessment included isokinetic elbow strength and endurance testing by using multiple angular velocities to simulate the “off-season” and “precompetition” phases of training. Eighteen months postoperatively and after full return to training, the biomechanical assessment indicated that the strength and endurance of the operated elbow joint was fully restored with even higher ratings compared to the contralateral healthy arm. The described reconstruction technique can be considered as an advisable option in high-performance athletes with underlying poor tendon quality due to high tensile strength and lack of donor site morbidity, thus enabling them to restore preinjury status and achieve safe return to sports. PMID:24711944

  13. Pectoralis Major Tear with Retracted Tendon: How to Fill the Gap? Reconstruction with Hamstring Autograft and Fixation with an Interference Screw

    Directory of Open Access Journals (Sweden)

    L. Baverel

    2017-01-01

    Full Text Available Rupture of the pectoralis major tendon is considered an uncommon injury and a significant number of ruptures are missed or diagnosed late, leading to a chronic tear. We report an open reconstruction technique and its outcomes in a case of chronic and retracted PM tear. At the last follow-up (12 months, the patient was pain-free, with a visual analogic scale at 0 all the time. He was very satisfied concerning the cosmetic and clinical results. The constant score was 93%, the SST value 95%, and the Quick DASH score 4.5. MRI performed one year postoperatively confirmed the continuity between PM tendon and graft, even if the aspect of the distal tendon seemed to be thinner than normal PM tendon. The excellent clinical outcomes at one-year follow-up suggest that PM tear with major tendon retraction can be reliably reconstructed with hamstring autograft, using a bioabsorbable screw to optimize the fixation device. This technique has proven its simplicity and efficiency to fill the gap.

  14. One-stage bilateral anterior cruciate ligament reconstruction with use of hamstring tendon autografts: a case report

    Directory of Open Access Journals (Sweden)

    Matjaž Sajovic

    2007-12-01

    Full Text Available Background: Bilateral ACL rupture is not a common clinical problem, but the incidence of the bilateral knee injuries is increasing especially within highly sports active population. Mechanism of the injury rarely causes simultaneous bilateral ACL tear. Usually unilateral injury of the knee has occurred and later on contralateral injury has taken place.Patient and methods: Case report presented an unusual problem of a patient with chronic bilateral ACL – deficient knees and constitutionally very thin patellar tendons. Author decided to perform onestage bilateral ACL reconstructions using hamstring tendon autographs so as not too weaken his quadriceps muscles by compromising his extensor mechanism.Results: At three years follow-up the patient’s opinion was that both ACL reconstructed knees had normal function, and he had returned to his preinjury activity level. The overall result of the Lysholm knee score for left knee was 100 and for right one 95. Both knees had full range of motion, Lachman and pivot shift signs were negative.Conclusions: Two-stage bilateral ACL reconstruction is much more time consuming for the patient and expensive for health insurance, so one-stage bilateral ACL reconstruction is a logical solution of the problem.

  15. Press-fit Femoral Fixation in ACL Reconstruction using Bone-Patellar Tendon-Bone Graft

    Directory of Open Access Journals (Sweden)

    Kaseb Mohammad Hasan

    2009-05-01

    Full Text Available Bone-patellar tendon auto graft is probably the most widely used graft for ACL reconstruction. Several methods for graft fixation have been described. To avoid intra-articular hardware we adopt biological fixation with a femoral trapezoidal press-fit fixation. A prospective study was performed on 30 consecutive active people who underwent ACL reconstruction with this technique by two surgeons between september2004 and march2007 (mean follow-up 15.2 months. Results were evaluated by an independent examiner using radiography, subjective and objective evaluation. Assessment using the IKDC knee scoring revealed 92% of the patients with a normal or nearly normal knee joint. Lysholm's score was 63.6(40- 86 preoperatively and 91.88(73-100 at the latest follow up (P < 0.005. No patient complained of instability at latest follow up. The quadriceps muscle showed mild atrophy at 3 and 6 months and at final follow-up. Five Patients complained of anterior knee pain and had a positive kneeling test. We found no graft displacement on follow up radiographs. All cases showed radiological evidence of graft osteointegration at last follow up. Our results show that press-fit fixation of trapezoidal bone graft in femoral tunnel is a simple, reliable, and cost-effective alternative for ACL recon-struction using bone-patellar tendon-bone graft.

  16. A Modified Method for Reconstruction of Chronic Rupture of the Quadriceps Tendon after Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    S Singh

    2008-11-01

    Full Text Available We describe herein a modified technique for reconstruction of chronic rupture of the quadriceps tendon in a patient with bilateral total knee replacement and distal realignment of the patella. The surgery involved the application of a Dacron graft and the ‘double eights’ technique. The patient achieved satisfactory results after surgery and we believe that this technique of reconstruction offers advantages over other methods.

  17. Leiomyosarcoma of inferior vena cava involving bilateral renal veins: Surgical challenges and reconstruction with upfront saphenous vein interposition graft for left renal vein outflow

    Directory of Open Access Journals (Sweden)

    Rishi Nayyar

    2010-01-01

    Full Text Available Leiomyosarcoma of inferior vena cava (IVC involving bilateral renal veins presents a surgical challenge. Herein, we report the successful management of two such cases using restoration of left renal venous outflow by saphenous vein interposition graft as first step of surgery. Then radical resection of tumor and right kidney was done. IVC was lastly reconstructed using Gore-Tex graft. This report highlights the surgical challenges to ensure radical resection. Furthermore, the importance of restoring left renal outflow in presence of concomitant right nephrectomy is discussed. Both the patients were disease free at six months with no loss of left renal glomerular filtration rate.

  18. Effects of knee immobilization on morphological changes in the semitendinosus muscle-tendon complex after hamstring harvesting for anterior cruciate ligament reconstruction. Evaluation using three-dimensional computed tomography

    International Nuclear Information System (INIS)

    Nakamae, Atsuo; Adachi, Nobuo; Nakasa, Tomoyuki; Nishimori, Makoto; Ochi, Mitsuo; Deie, Masataka

    2012-01-01

    It is desirable to maintain the morphology of the semitendinosus muscle-tendon complex after tendon harvesting for anterior cruciate ligament (ACL) reconstruction. The purpose of this study was to evaluate the effect of knee immobilization on morphological changes in the semitendinosus muscle-tendon complex. In total, 39 patients who underwent ACL reconstruction with autologous semitendinosus tendons were included in this study. After surgery, the knee was immobilized for 3 days in 1 group of patients (group 1; 24 patients; control group) and for a longer period (10-14 days) in the other group (group 2; 15 patients). Three-dimensional computed tomography (3D CT) examination was performed at 6 and/or 12 months after the surgery for all patients. Morphological changes in the semitendinosus muscle-tendon complex (proximal shift of the semitendinosus muscle-tendon junction, width of the regenerated semitendinosus tendons, re-insertion sites of the regenerated tendons, and rate of semitendinosus tendon regeneration) were evaluated. Successful regeneration of the semitendinosus tendon was confirmed in all patients in group 2. In group 1, 3D CT showed that regeneration of the semitendinosus tendon was unsuccessful in 1 of the 24 patients. The average length of the proximal shift of the semitendinosus muscle-tendon junction was 7.3±2.5 cm in group 1 and 7.2±1.9 cm in group 2. There were no significant differences between the 2 groups with regard to the morphological changes in the semitendinosus muscle-tendon complex. This study showed that the structure of regenerated tendons could be clearly identified in 38 of 39 cases (97.4%) after ACL reconstruction. However, prolonged knee immobilization (10-14 days) could not prevent morphological changes in the semitendinosus muscle-tendon complex. (author)

  19. Double-bundle PCL reconstruction using autologous hamstring tendons: outcome with a minimum 2-year follow-up

    Directory of Open Access Journals (Sweden)

    Ricardo de Paula Leite Cury

    Full Text Available ABSTRACT OBJECTIVE: To present the outcomes of posterior cruciate ligament (PCL double-bundle reconstruction using autologous hamstring tendons, with a minimum follow-up of two years. METHODS: Evaluation of 16 cases of PCL injury that underwent double-bundle reconstruction with autogenous hamstring tendons, between 2011 and 2013. The final sample consisted of 16 patients, 15 men and one woman, with a mean age of 31 years (21-49. The predominant mechanism was motorcycle accident in half of the cases. There was a mean interval of 15 months between the time of lesion and the surgery (three to 52 months. Five lesions were isolated and 11, associated. Clinical evaluation, application of validated scores, and measurements with use of the KT-1000 were performed. RESULTS: The analysis showed a mean preoperative Lysholm score of 50 points (28-87, progressing to 94 points (85-100 postoperatively. The IKDC score also demonstrated improvement. In the preoperative evaluation, four and 12 patients were respectively classified as C (abnormal and D (very unusual, and in the postoperative evaluation six as A (normal and ten as B (close to normal. In the post-operative evaluation by KT1000 arthrometer, 13 patients showed difference between 0-2 mm and 3 between 3 and 5 mm, when compared with the contralateral side. CONCLUSION: Autologous hamstring tendons are a viable option in double-bundle reconstruction of the PCL, with good clinical results in a minimum follow-up of two years.

  20. Step Cut Lengthening: A Technique for Treatment of Flexor Pollicis Longus Tendon Rupture.

    Science.gov (United States)

    Chong, Chew-Wei; Chen, Shih-Heng

    2018-04-01

    Reconstruction of a tendon defect is a challenging task in hand surgery. Delayed repair of a ruptured flexor pollicis longus (FPL) tendon is often associated with tendon defect. Primary repair of the tendon is often not possible, particularly after debridement of the unhealthy segment of the tendon. As such, various surgical treatments have been described in the literature, including single-stage tendon grafting, 2-stage tendon grafting, flexor digitorum superficialis tendon transfer from ring finger, and interphalangeal joint arthrodesis. We describe step cut lengthening of FPL tendon for the reconstruction of FPL rupture. This is a single-stage reconstruction without the need for tendon grafting or tendon transfer. To our knowledge, no such technique has been previously described.

  1. Predictors and effects of patellofemoral pain following hamstring-tendon ACL reconstruction.

    Science.gov (United States)

    Culvenor, Adam G; Collins, Natalie J; Vicenzino, Bill; Cook, Jill L; Whitehead, Timothy S; Morris, Hayden G; Crossley, Kay M

    2016-07-01

    Patellofemoral pain is a frequent and troublesome complication following anterior cruciate ligament reconstruction (ACLR), irrespective of graft source. Yet, little is known about the factors associated with patellofemoral pain following hamstring-tendon ACLR. Retrospective analysis of potential patellofemoral pain predictors, and cross-sectional analysis of possible patellofemoral pain consequences. Potential predictors (pre-injury patellofemoral pain and activity level, concomitant patellofemoral cartilage damage and meniscectomy, age, sex, and surgical delay) and consequences (hopping performance, quality of life, kinesiophobia, and return to sport rates and attitudes) of patellofemoral pain 12 months following hamstring-tendon ACLR were assessed in 110 participants using univariate and multivariate analyses. Thirty-three participants (30%) had patellofemoral pain at 12 months post-ACLR. Older age at the time of ACLR was the only predictor of post-operative patellofemoral pain. Following ACLR, those with patellofemoral pain had a higher body mass index, and worse physical performance, quality of life, kinesiophobia and return to sport attitudes. Patellofemoral pain has a significant burden on individuals 12 months following hamstring-tendon ACLR. Clinicians need to be cognisant of patellofemoral pain, particularly in older individuals and those with a higher body mass index. The importance of considering psychological factors that are not typically addressed during ACLR rehabilitation, such as kinesiophobia, quality of life and return to sport attitudes is emphasised. Copyright © 2016. Published by Elsevier Ltd.

  2. Anterior-Posterior Instability of the Knee Following ACL Reconstruction with Bone-Patellar Tendon-Bone Ligament in Comparison with Four-Strand Hamstrings Autograft

    Directory of Open Access Journals (Sweden)

    A. G. Angoules

    2013-01-01

    Full Text Available Purpose. To evaluate anterior-posterior knee laxity using two different autografts. Material-Methods. 40 patients, (34 males and 6 women, 17–54 years old (mean: 31, were included in the present study. Group A (4SHS = 20 underwent reconstruction using four-strand hamstrings, and group B (BPBT = 20 underwent reconstruction using bone-patellar tendon-bone autograft. Using the KT-1000 arthrometer, knee instability was calculated in both knees of all patients preoperatively and 3, 6, and 12 months after surgery at the ACL-operated knee. The contralateral healthy knee was used as an internal control group. Results. Anterior-posterior instability using the KT1000 Arthrometer was found to be increased after ACL insufficiency. The recorded laxity improved after arthroscopic ACL reconstruction in both groups. However, statistically significant greater values were detected in the bone-patellar tendon-bone group, which revealed reduction of anteroposterior stability values to an extent, where no statistical significance with the normal values even after 3 months after surgery was observed. Conclusions. Anterior-Posterior instability of the knee improved significantly after arthroscopic ACL reconstruction. The bone-patellar tendon-bone graft provided an obvious greater stability.

  3. ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION: A COMPARISON BETWEEN BONE PATELLAR TENDON BONE GRAFT AND LIPSCOMB PROCEDURE - A FOLLOWUP STUDY OF 7 YEARS

    Directory of Open Access Journals (Sweden)

    Vijayamohan S

    2016-07-01

    Full Text Available BACKGROUND Anterior Cruciate Ligament injury has become more common and the demand by the patients to return to pre-injury level of activity has made reconstruction of the ligament very crucial. Though there are various techniques in reconstructing the anterior cruciate ligament, in this study, we compare two most commonly used techniques to see whether there is any significant difference in the outcome. METHODS Study included 25 patients in the age group of 19-36 years, of which 23 were males. The patients were divided randomly into 2 groups, and 15 patients underwent Anterior Cruciate Ligament reconstruction using Bone Patellar Tendon Bone Graft and 10 patients had Hamstring graft. RESULTS Patients were followed up at regular intervals monthly for the first six months and then at three monthly intervals. Patients were assessed using Knee Scoring Scale of Lysholm and Gillquist and International Knee Documentation Committee (IKDC scoring system. In addition, activity level, harvest site pain, thigh atrophy, kneeling pain and hamstring pain were assessed. All patients were followed up for a minimum period of 2 years. 20% of both groups were able to return to strenuous activity level, and 67% of Patellar tendon group and 50% of the Hamstring tendon group were able to return to moderate level of activity. 55% of patients in the patellar tendon group and 20% of patients in the hamstring tendon group had donor site pain in the first 6 months. 73% of patients in the hamstring group had at least 10 mm of thigh wasting. Pain on kneeling was seen only in the patellar tendon group (35% while hamstring pain was found only in the hamstring group (20%. CONCLUSIONS Patients in the patellar tendon group had increased anterior stability and were able to return to strenuous occupation. The difference in thigh atrophy between the two groups was not significant. The hamstring group had lower graft harvest site morbidity. Lachman test was the single most accurate

  4. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model

    OpenAIRE

    Li, Shengkun; Ma, Kui; Li, Hong; Jiang, Jia; Chen, Shiyi

    2016-01-01

    The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET) artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA) is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired w...

  5. Arthroscopic intra- and extra-articular anterior cruciate ligament reconstruction with gracilis and semitendinosus tendons: a review

    OpenAIRE

    Marcacci, Maurilio; Zaffagnini, Stefano; Marcheggiani Muccioli, Giulio Maria; Neri, Maria Pia; Bondi, Alice; Nitri, Marco; Bonanzinga, Tommaso; Grassi, Alberto

    2011-01-01

    The purposes of this paper are to summarize the concepts relating to the use of a combined intra-articular and extra-articular reconstructive procedure in the arthroscopic treatment of a torn ACL and to review several operative techniques utilizing gracilis and semitendinosus tendons that are currently in use to treat this instability. The highly satisfactory results obtained over the time show that a combination of intra- and extra-articular procedures for ACL reconstruction is a valid surgi...

  6. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model.

    Science.gov (United States)

    Li, Shengkun; Ma, Kui; Li, Hong; Jiang, Jia; Chen, Shiyi

    2016-01-01

    The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET) artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA) is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired with PET were assigned to PET group; the other eight rabbits repaired with PET along with injection of HE were assigned to HA-PET group. All rabbits were sacrificed at 4 and 8 weeks postoperatively for biomechanical and histological examination. The HA-PET group revealed higher biomechanical property compared with the PET group. Histologically, more collagen tissues grew into the HA-PET group compared with PET group. In conclusion, application of sodium hyaluronate can improve the healing of Achilles tendon reconstruction with polyethylene terephthalate artificial ligament.

  7. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model

    Directory of Open Access Journals (Sweden)

    Shengkun Li

    2016-01-01

    Full Text Available The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired with PET were assigned to PET group; the other eight rabbits repaired with PET along with injection of HE were assigned to HA-PET group. All rabbits were sacrificed at 4 and 8 weeks postoperatively for biomechanical and histological examination. The HA-PET group revealed higher biomechanical property compared with the PET group. Histologically, more collagen tissues grew into the HA-PET group compared with PET group. In conclusion, application of sodium hyaluronate can improve the healing of Achilles tendon reconstruction with polyethylene terephthalate artificial ligament.

  8. One-stage Pelnac Reconstruction in Full-thickness Skin Defects with Bone or Tendon Exposure

    Directory of Open Access Journals (Sweden)

    Xianghong Lou, MS

    2018-03-01

    Full Text Available Summary:. Dermal regeneration template, such as Integra and Pelnac, was originally designed for treating large area burn injury by inducing regeneration of dermis. To date, it has been widely applied in various acute and chronic wound sites. The present study demonstrated that application of artificial dermis alone induced 1-stage wound healing for wounds with bone or tendon exposure that should usually be repaired by flap surgery. Eight patients who presented with skin defects with bone and/or tendon exposure were treated by 1-stage Pelnac approach. All wounds healed within 20 weeks without skin graft or flap surgery. The wound area was reconstructed by nearly normal skin structure and linear scar. In the case of scalp defect, evidence of hair follicle cell migration and regeneration during healing process was observed. Thereby, the 1-stage Pelnac reconstitution can be considered as a novel method for inducing regrowth of epidermis and hair follicles to cure large full-thickness skin defect with bone and tendon exposure in 1 stage.

  9. A Canine Arthroscopic Anterior Cruciate Ligament Reconstruction Model for Study of Synthetic Augmentation of Tendon Allografts.

    Science.gov (United States)

    Cook, James L; Smith, Pat; Stannard, James P; Pfeiffer, Ferris; Kuroki, Keiichi; Bozynski, Chantelle C; Cook, Cristi

    2017-09-01

    Novel graft types, fixation methods, and means for augmenting anterior cruciate ligament (ACL) reconstructions require preclinical validation prior to safe and effective clinical application. The objective of this study was to describe and validate a translational canine model for all-inside arthroscopic complete ACL reconstruction using a quadriceps tendon allograft with internal brace (QTIB). With institutional approval, adult research hounds underwent complete transection of the native ACL followed by all-inside ACL reconstruction using the novel QTIB construct with suspensory fixation ( n  = 10). Contralateral knees were used as nonoperated controls ( n  = 10). Dogs were assessed over a 6-month period using functional, diagnostic imaging, gross, biomechanical, and histologic outcome measures required for preclinical animal models. Study results suggest that the novel QTIB construct used for complete ACL reconstruction can provide sustained knee stability and function without the development of premature osteoarthritis in a rigorous and valid preclinical model. The unique configuration of the QTIB construct-the combination of a tendon allograft with a synthetic suture tape internal brace-allowed for an effective biologic-synthetic load-sharing ACL construct. It prevented early failure, allowed for direct, four-zone graft-to-bone healing, and functional graft remodeling while avoiding problems noted with use of all-synthetic grafts. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. Tendon allograft sterilized by peracetic acid/ethanol combined with gamma irradiation.

    Science.gov (United States)

    Zhou, Mo; Zhang, Naili; Liu, Xiaoming; Li, Youchen; Zhang, Yumin; Wang, Xusheng; Li, Baoming; Li, Baoxing

    2014-07-01

    Research and clinical applications have demonstrated that the effects of tendon allografts are comparable to those of autografts when reconstructing injured tendons or ligaments, but allograft safety remains problematic. Sterilisation could eliminate or decrease the possibility of disease transmission, but current methods seldom achieve satisfactory sterilisation without affecting the mechanical properties of the tendon. Peracetic acid-ethanol in combination with low-dose gamma irradiation (PE-R) would inactivate potential deleterious microorganisms without affecting mechanical and biocompatible properties of tendon allograft. Controlled laboratory design. HIV, PPV, PRV and BVDV inactivation was evaluated. After verifying viral inactivation, the treated tendon allografts were characterised by optical microscopy, scanning electron microscopy and tensile testing, and the cytocompatibility was assessed with an MTT assay and by subcutaneous implantation. Effective and efficient inactivation of HIV, PPV, PRV and BVDV was observed. Histological structure and ultrastructure were unchanged in the treated tendon allograft, which also exhibited comparable biomechanical properties and good biocompatibility. The preliminary results confirmed our hypothesis and demonstrated that the PE-R tendon allograft has significant potential as an alternative to ligament/tendon reconstruction. Tendon allografts have been extensively used in ligament reconstruction and tendon repair. However, current sterilisation methods have various shortcomings, so PE-R has been proposed. This study suggests that PE-R tendon allograft has great potential as an alternative for ligament/tendon reconstruction. Sterilisation has been a great concern for tendon allografts. However, most sterilisation methods cannot inactivate viruses and bacteria without impairing the mechanical properties of the tendon allograft. Peracetic acid/ethanol with gamma irradiation can effectively inactivate viruses and bacteria

  11. Aesthetically and functionally satisfying reconstruction of an Achilles tendon and overlying skin defect in a 15 year old girl: a case report.

    Science.gov (United States)

    Wurzer, Paul; Eberl, Robert; Kamolz, Lars-Peter; Parvizi, Daryousch; Rappl, Thomas; Spendel, Stephan

    2015-03-01

    Achilles tendon and overlying soft tissue reconstruction presents an interdisciplinary challenge. In the literature many possible procedures are described, but each reconstruction in this region has its specific demands. Single stage reconstruction is normally pursued, but it is not always the best procedure for the patient, either aesthetically or functionally. We present a case of a 15 year old girl who suffered a soft tissue defect of 10cm×6cm in size at the area of the Achilles tendon due to a contact burn by an exhaust pipe during a motorcycle accident. For this case, reconstruction of the soft tissue defect using a free temporoparietal fascial flap (TPFF) and a full-thickness skin autograft was the best means to provide a satisfying result for both the patient and the surgeon. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  12. The use of hamstring tendon graft for the anterior cruciate ligament reconstruction (benefi ts, problems and their solutions

    Directory of Open Access Journals (Sweden)

    V. V. Slastinin

    2017-01-01

    Full Text Available The search for optimal graft for anterior cruciate ligament reconstruction is going on. The donor site morbidity remains one of the major problems when using autografts. The article provides an overview of the advantages and disadvantages of using the hamstring tendon autografts for anterior cruciate ligament reconstruction, and the ways of solving the problems associated with using such types of grafts.

  13. Biomechanical Effects of Acromioplasty on Superior Capsule Reconstruction for Irreparable Supraspinatus Tendon Tears.

    Science.gov (United States)

    Mihata, Teruhisa; McGarry, Michelle H; Kahn, Timothy; Goldberg, Iliya; Neo, Masashi; Lee, Thay Q

    2016-01-01

    Acromioplasty is increasingly being performed for both reparable and irreparable rotator cuff tears. However, acromioplasty may destroy the coracoacromial arch, including the coracoacromial ligament, consequently causing a deterioration in superior stability even after superior capsule reconstruction. The purpose of this study was to investigate the effects of acromioplasty on shoulder biomechanics after superior capsule reconstruction for irreparable supraspinatus tendon tears. The hypothesis was that acromioplasty with superior capsule reconstruction would decrease the area of subacromial impingement without increasing superior translation and subacromial contact pressure. Controlled laboratory study. Seven fresh-frozen cadaveric shoulders were evaluated using a custom shoulder testing system. Glenohumeral superior translation, the location of the humeral head relative to the glenoid, and subacromial contact pressure and area were compared among 4 conditions: (1) intact shoulder, (2) irreparable supraspinatus tendon tear, (3) superior capsule reconstruction without acromioplasty, and (4) superior capsule reconstruction with acromioplasty. Superior capsule reconstruction was performed using the fascia lata. Compared with the intact shoulder, the creation of an irreparable supraspinatus tear significantly shifted the humeral head superiorly in the balanced muscle loading condition (without superior force applied) (0° of abduction: 2.8-mm superior shift [P = .0005]; 30° of abduction: 1.9-mm superior shift [P = .003]) and increased both superior translation (0° of abduction: 239% of intact [P = .04]; 30° of abduction: 199% of intact [P = .02]) and subacromial peak contact pressure (0° of abduction: 308% of intact [P = .0002]; 30° of abduction: 252% of intact [P = .001]) by applying superior force. Superior capsule reconstruction without acromioplasty significantly decreased superior translation (0° of abduction: 86% of intact [P = .02]; 30° of abduction: 75

  14. Anatomical Footprint of the Tibialis Anterior Tendon: Surgical Implications for Foot and Ankle Reconstructions

    Directory of Open Access Journals (Sweden)

    Madeleine Willegger

    2017-01-01

    Full Text Available This study aimed to analyze precisely the dimensions, shapes, and variations of the insertional footprints of the tibialis anterior tendon (TAT at the medial cuneiform (MC and first metatarsal (MT1 base. Forty-one formalin-fixed human cadaveric specimens were dissected. After preparation of the TAT footprint, standardized photographs were made and the following parameters were evaluated: the footprint length, width, area of insertion, dorsoplantar location, shape, and additional tendon slips. Twenty feet (48.8% showed an equal insertion at the MC and MT1, another 20 feet (48.8% had a wide insertion at the MC and a narrow insertion at the MT1, and 1 foot (2.4% demonstrated a narrow insertion at the MC and a wide insertion at the MT1. Additional tendon slips inserting at the metatarsal shaft were found in two feet (4.8%. Regarding the dorsoplantar orientation, the footprints were located medial in 29 feet (70.7% and medioplantar in 12 feet (29.3%. The most common shape at the MT1 base was the crescent type (75.6% and the oval type at the MC (58.5%. The present study provided more detailed data on the dimensions and morphologic types of the tibialis anterior tendon footprint. The established anatomical data may allow for a safer surgical preparation and a more anatomical reconstruction.

  15. Colon interposition

    International Nuclear Information System (INIS)

    Isolauri, J.; Tampere Univ. Central Hospital; Paakkala, T.; Arajaervi, P.; Markkula, H.

    1987-01-01

    Colon interposition was carried out in 12 patients with oesophageal carcinoma and on 38 patients with benign oesophageal disease an average of 71 months before the radiographic examination. Various ischaemic changes including 'jejunization', loss of haustration and stricture formation were observed in 15 cases. In 12 patients one or several diverticula were seen in the colon graft. Reflux was observed in 17 cases in supine position. Double contrast technique in the examination of interposed colon is recommended. (orig.)

  16. Biology and augmentation of tendon-bone insertion repair

    OpenAIRE

    Lui, PPY; Zhang, P; Chan, KM; Qin, L

    2010-01-01

    Abstract Surgical reattachment of tendon and bone such as in rotator cuff repair, patellar-patella tendon repair and anterior cruciate ligament (ACL) reconstruction often fails due to the failure of regeneration of the specialized tissue ("enthesis") which connects tendon to bone. Tendon-to-bone healing taking place between inhomogenous tissues is a slow process compared to healing within homogenous tissue, such as tendon to tendon or bone to bone healing. Therefore special attention must be ...

  17. Peri-Vesical Fat Interposition Flap Reinforcement in High Vesico ...

    African Journals Online (AJOL)

    Background and Aim: The urinary bladder becomes small, contracted and is associated with excess pelvic fat in long standing cases of vesico-vaginal fistulas (VVFs). The aim of this new technique was to use this excess pelvic fat for harvesting an interposition flap. Materials and Methods: An interposition flap of peri-vesical ...

  18. Anterior cruciate ligament- and hamstring tendon- derived cells: in vitro differential properties of cells involved in ACL reconstruction

    NARCIS (Netherlands)

    Ghebes, C.A.; Kelder, C.; Schot, T.; Renard, A.J.S.; Pakvis, D.F.M.; Fernandes, H.; Saris, Daniël B.F.

    2015-01-01

    Anterior cruciate ligament (ACL) reconstruction involves the replacement of the torn ligament with a new graft, often a hamstring tendon (HT). Described as similar, the ACL and HT have intrinsic differences related to their distinct anatomical locations. From a cellular perspective, identifying

  19. Outcomes After Interpositional Arthroplasty of the First Metatarsophalangeal Joint.

    Science.gov (United States)

    Aynardi, Michael C; Atwater, Lara; Dein, Eric J; Zahoor, Talal; Schon, Lew C; Miller, Stuart D

    2017-05-01

    For patients with hallux rigidus seeking a motion-sparing procedure, interposition arthroplasty is an alternative to fusion. The purpose of this study was to report patient outcomes after interpositional arthroplasty for hallux rigidus. All patients undergoing interpositional arthroplasty at our institution from 2001 to 2014 were identified and a retrospective chart review was performed. Follow-up was conducted through a telephone survey to obtain survivorship, satisfaction, and functional scores. Survivorship of the interpositional arthroplasty procedure was defined as no subsequent surgery on the hallux after the index procedure. Patients were excluded for incomplete records. Complications were recorded. From 2001 to 2014, 183 patients were identified. Of these, 14 were excluded for incomplete data, leaving 169 patients. Of these, 133 had an average follow-up of 62.2 months (range, 24.3 months to 151.2 months). The overall failure rate was 3.8% (5/133). Patient-reported outcome was rated as excellent in 65.4% (87/133) or good in 24.1% (32/133) of patients and fair or poor in 10.5% (14/133) of patients. Of 133 patients, 101 (76%) were able to return to fashionable or regular footwear. The infection rate was 1.5% (2/133). Patient-reported cock-up deformity of the first metatarsophalangeal joint (MTPJ) occurred in 4.5% (6/133) of patients. In addition, 17.3% (23/133) of patients reported metatarsalgia of the second or third MTPJ at the time of final follow-up, and there was no significant difference between interposition types ( P = .441). Interpositional arthroplasty for hallux rigidus was found to have excellent or good results in most patients at a mean follow-up of 62.2 months. Level IV, retrospective case series.

  20. Outcomes of the patellar tendon and hamstring graft anterior cruciate ligament reconstructions in patients aged above 50 years

    Directory of Open Access Journals (Sweden)

    Tarun Bali

    2015-01-01

    Full Text Available Background: The treatment of anterior cruciate ligament (ACL injury consists of arthroscopic ACL reconstruction with patellar tendon or hamstring graft. Satisfactory results have been reported so far in the younger age group. Dilemma arises regarding the suitability of ACL reconstruction in the patients aged 50 years and above. This retrospective analyses the outcome of ACL reconstruction in patients aged 50 years and above at the time of presentation. Materials and Methods: 55 patients aged 50 years and above presented to our institution with symptomatic ACL tear and were managed with arthroscopic reconstruction with patellar tendon/hamstring graft. 22 patients underwent ACL reconstruction with bone- patellar tendon-bone graft and the remaining 33 with a hamstring graft. Evaluation of functional outcome was performed using International Knee Documentation Committee (IKDC and Lysholm scoring in the preoperative period, at the end of 1 year and at the final followup. Radiographic evaluation was performed using the Kellgren–Lawrence grading system. Results: The mean preoperative IKDC score was 39.7 ± 3.3. At the end of 1-year following the operation, the mean IKDC score was 73.6 ± 4.9 and at the final followup was 67.8 ± 7.7. The mean preoperative Lysholm score was 40.4 ± 10.3. At the end of 1-year following the intervention, the mean Lysholm score was 89.7 ± 2.1 and at final followup was 85.3 ± 2.5. Overall, 14 out of 42 patients who underwent radiographic assessment showed progression of osteoarthritis changes at the final followup after the intervention. Conclusion: In our study, there was a statistically significant improvement in the IKDC and Lysholm scores following the intervention. There was a slight deterioration in the scores at the final followup but the overall rate of satisfaction was still high and most of the patients were able to do their routine chores and light exercises suitable for their age group. Around one-third of

  1. Medial Patellofemoral Ligament Reconstruction Using the Hamstring Tendon for Patellofemoral Joint Instability in an 81-Year-Old Female.

    Science.gov (United States)

    Takahashi, Tsuneari; Takeshita, Katsushi

    2017-01-01

    Chronic patellofemoral instability occurs mainly in adolescent females and can also be induced by medial patellofemoral ligament (MPFL) injury. There are no case reports of MPFL reconstruction for chronic patellofemoral instability due to MPFL injury in aged populations. 81-year-old female presented with left knee pain, giving way, and patellar instability while climbing stairs, which continued for 18 months. Patellar apprehension test was positive, and roentgenogram showed lateral patellar subluxation. Conservative therapy was not successful; hence, we performed a lateral release and MPFL reconstruction surgery. After arthroscopic lateral release, the hamstring tendon was harvested, and a graft composite made of doubled hamstring tendon and polyester tape with a suspensory fixation device was prepared. Then, a femoral bone tunnel was constructed in a socket shape at the anatomical footprint of the MPFL. The graft was passed through the femoral tunnel, and free ends of the graft composite were sutured to the periosteum of the patella, using two suture anchors at 60° of knee flexion with patellar reduction. Physiotherapy was gradually started using a patella-stabilizing orthosis on the first postoperative day. Her Kujala score improved from 66 to 97 points, and Barthel index score improved from 70 to 100 points at 1 year after surgery. She neither developed patellofemoral joint OA nor had any recurrence of symptoms at the 5-year postoperative follow up. MPFL reconstruction using the hamstring tendon is an effective procedure for patients with chronic patellofemoral instability even after the age of 80 years.

  2. Negative pressure wound therapy in the management of late deep infections after open reconstruction of achilles tendon rupture.

    Science.gov (United States)

    Mosser, Philipp; Kelm, Jens; Anagnostakos, Konstantinos

    2015-01-01

    Infection is a major complication after open reconstruction of Achilles tendon ruptures. We report on the use of vacuum-assisted closure (VAC) therapy in the treatment of late deep infections after open Achilles tendon reconstruction. Six patients (5 males [83.33%], 1 female [16.67%]; mean age, 52.8 [range 37 to 66] years) were been treated using an identical protocol. Surgical management consisted of debridement, lavage, and necrectomy of infected tendon parts. The VAC therapy was used for local wound preconditioning and infection management. A continuous negative pressure of 125 mm Hg was applied on each wound. For final wound closure, a split-thickness skin graft was performed. The skin graft healing process was also supported by VAC therapy during the first 5 days. The VAC dressings were changed a mean average of 3 (range 1 to 4) times until split-thickness skin grafting could be performed. The mean total duration of the VAC therapy was 13.6 ± 5.9 days. The mean hospital stay was 31.2 ± 15.9 days. No complications with regard to bleeding, seroma, or hematoma formation beneath the skin graft were observed. At a mean follow-up duration of 29.9 (range 4 to 65) months, no re-infection or infection persistence was observed. The VAC device seems to be a valuable tool in the treatment of infected tendons. The generalization of these conclusions should await the results of future studies with larger patient series. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Acromioclavicular joint dislocation: a comparative biomechanical study of the palmaris-longus tendon graft reconstruction with other augmentative methods in cadaveric models

    Directory of Open Access Journals (Sweden)

    Sengupta S

    2007-11-01

    Full Text Available Abstract Background Acromioclavicular injuries are common in sports medicine. Surgical intervention is generally advocated for chronic instability of Rockwood grade III and more severe injuries. Various methods of coracoclavicular ligament reconstruction and augmentation have been described. The objective of this study is to compare the biomechanical properties of a novel palmaris-longus tendon reconstruction with those of the native AC+CC ligaments, the modified Weaver-Dunn reconstruction, the ACJ capsuloligamentous complex repair, screw and clavicle hook plate augmentation. Hypothesis There is no difference, biomechanically, amongst the various reconstruction and augmentative methods. Study Design Controlled laboratory cadaveric study. Methods 54 cadaveric native (acromioclavicular and coracoclavicular ligaments were tested using the Instron machine. Superior loading was performed in the 6 groups: 1 in the intact states, 2 after modified Weaver-Dunn reconstruction (WD, 3 after modified Weaver-Dunn reconstruction with acromioclavicular joint capsuloligamentous repair (WD.ACJ, 4 after modified Weaver-Dunn reconstruction with clavicular hook plate augmentation (WD.CP or 5 after modified Weaver-Dunn reconstruction with coracoclavicular screw augmentation (WD.BS and 6 after modified Weaver-Dunn reconstruction with mersilene tape-palmaris-longus tendon graft reconstruction (WD. PLmt. Posterior-anterior (horizontal loading was similarly performed in all groups, except groups 4 and 5. The respective failure loads, stiffnesses, displacements at failure and modes of failure were recorded. Data analysis was carried out using a one-way ANOVA, with Student's unpaired t-test for unpaired data (S-PLUS statistical package 2005. Results Native ligaments were the strongest and stiffest when compared to other modes of reconstruction and augmentation except coracoclavicular screw, in both posterior-anterior and superior directions (p WD.ACJ provided additional

  4. The effect of isoperistaltic jejunal interposition upon gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Mackie, C.R.; Hall, A.W.; Clark, J.; Wisbey, M.; Baker, P.R.; Cuschieri, A.

    1981-12-01

    Ten patients with severe postgastrectomy-postvagotomy symptoms, all of whom had the features of vasomotor dumping, underwent gastric emptying studies, using a 300 milliliter meal of 15 per cent dextrose labeled with 99mTc-sulphur colloid. Studies were repeated two to 11 months following remedial operative treatment, using a 12.5 to 15.0 centimeter isoperistaltic jejunal interposition. Preoperatively, all patients had rapid gastric emptying with a typical biphasic pattern. Following isoperistaltic interposition, the rate of gastric emptying was similar to that found in control patients. Gastric emptying reverted to a more normal pattern but, as in the preoperative studies, was best described by a double exponential function, consisting of slow and fast components. Analysis of these particular functions suggests the manner in which isoperistaltic interposition modified the underlying disorder of gastric motility.

  5. IFSSH Flexor Tendon Committee report 2014: from the IFSSH Flexor Tendon Committee (Chairman: Jin Bo Tang).

    Science.gov (United States)

    Tang, Jin Bo; Chang, James; Elliot, David; Lalonde, Donald H; Sandow, Michael; Vögelin, Esther

    2014-01-01

    Hand surgeons continue to search for the best surgical flexor tendon repair and treatment of the tendon sheaths and pulleys, and they are attempting to establish postoperative regimens that fit diverse clinical needs. It is the purpose of this report to present the current views, methods, and suggestions of six senior hand surgeons from six different countries - all experienced in tendon repair and reconstruction. Although certainly there is common ground, the report presents provocative views and approaches. The report reflects an update in the views of the committee. We hope that it is helpful to surgeons and therapists in treating flexor tendon injuries.

  6. Reconstruction of Ligament and Tendon Defects Using Cell Technologies.

    Science.gov (United States)

    Chailakhyan, R K; Shekhter, A B; Ivannikov, S V; Tel'pukhov, V I; Suslin, D S; Gerasimov, Yu V; Tonenkov, A M; Grosheva, A G; Panyushkin, P V; Moskvina, I L; Vorob'eva, N N; Bagratashvili, V N

    2017-02-01

    We studied the possibility of restoring the integrity of the Achilles tendon in rabbits using autologous multipotent stromal cells. Collagen or gelatin sponges populated with cells were placed in a resorbable Vicryl mesh tube and this tissue-engineered construct was introduced into a defect of the middle part of the Achilles tendon. In 4 months, histological analysis showed complete regeneration of the tendon with the formation of parallel collagen fibers, spindle-shaped tenocytes, and newly formed vessels.

  7. Anatomic Double-Bundle Anterior Cruciate Ligament Reconstruction With a Free Quadriceps Tendon Autograft.

    Science.gov (United States)

    Caterev, Sergiu; Nistor, Dan Viorel; Todor, Adrian

    2016-10-01

    Anatomic double-bundle anterior cruciate ligament (ACL) reconstruction aims to restore the 2 functional bundles of the ACL in an attempt to better reproduce the native biomechanics of the injured knee and promote long-term knee health. However, this concept is not fully accepted and is not performed on a standard basis. In addition, the superiority of this technique over the conventional single-bundle technique has been questioned, especially the long-term clinical results. One of the down sides of the double-bundle reconstruction is the complexity of the procedure, with increased risks, operative time, and costs compared with the single-bundle procedure. Also, the revision procedure, if necessary, is more challenging. We propose a technique that has some advantages over the traditional double-bundle procedure, using a single femoral tunnel, 2 tibial tunnels, and a free quadriceps tendon autograft.

  8. Bilateral spontaneous rupture of flexor digitorum profundus tendons.

    LENUS (Irish Health Repository)

    O'Sullivan, S T

    2012-02-03

    Spontaneous tendon rupture is an unusual condition usually associated with underlying disease processes such as rheumatoid arthritis, chronic renal failure or bony abnormalities of the hand. We report a case of spontaneous, non-concurrent bilateral rupture of flexor profundus tendons in an otherwise healthy individual. Treatment was successful and consisted of a two-stage reconstruction of the ruptured tendon.

  9. [EFFECTIVENESS COMPARISON OF CORACOCLAVICULAR LIGAMENT RECONSTRUCTION BETWEEN BY AUTOLOGOUS AND ALLOGENEIC TENDON GRAFTS COMBINED WITH HOOK PLATE FIXATION FOR TREATING ACROMIOCLAVICULAR JOINT DISLOCATION].

    Science.gov (United States)

    Yin, Fei; Sun, Zhenzhong; Wei, Xuming; Liu, Xueguang; Zhou, Ming; Zhuang, Yin; Song, Sheng

    2016-05-08

    To compare the effectiveness of coracoclavicular ligament reconstruction between by using autologous plantaris tendon graft combined with hook plate fixation and allogeneic tendon graft combined with hook plate fixation for treating acromiocavicular joint dislocation. Thirty-three patients with acromioclavicular joint dislocation who accorded with the inclusion criteria between January 2013 and June 2014 were assigned into 2 groups. The patients were treated with autologous plantaris tendon graft combined with hook plate fixation in group A ( n =17), and with allogeneic tendon graft combined with hook plate fixation in group B ( n =16). Thirteen-one patients was followed up more than 12 months (15 in group A and 16 in group B). There was no significant difference in gender, age, cause of injury, sides, time between injury and surgery, and type of dislocation ( P >0.05). The assessments included operation time, hospitalization time, hospitalization expenses, shoulder range of motion, gap of acromioclavicular, Constant-Murley scores, and visual analogue scale (VAS) for pain. The operation time of group A was significantly longer than that of group B, and the hospitalization expense was significantly lower than that of group B ( P 0.05). No redislocation of acromioclavicular joint and rejection reaction occurred during follow-up. At last follow-up, there was no significant difference in shoulder range of motion, Constant-Murley score, and VAS score between 2 groups ( P >0.05). Coracoclavicular ligament reconstruction by autologous plantaris tendon or allogeneic tendon graft combined with hook plate fixation for the treatment of acromioclavicular joint dislocation can achieve good effectiveness. The appropriate treatment should be chosen according to the patient's economic situation.

  10. Phrenic nerve reconstruction in complete video-assisted thoracic surgery.

    Science.gov (United States)

    Kawashima, Shun; Kohno, Tadasu; Fujimori, Sakashi; Yokomakura, Naoya; Ikeda, Takeshi; Harano, Takashi; Suzuki, Souichiro; Iida, Takahiro; Sakai, Emi

    2015-01-01

    Primary or metastatic lung cancer or mediastinal tumours may at times involve the phrenic nerve and pericardium. To remove the pathology en bloc, the phrenic nerve must be resected. This results in phrenic nerve paralysis, which in turn reduces pulmonary function and quality of life. As a curative measure of this paralysis and thus a preventive measure against decreased pulmonary function and quality of life, we have performed immediate phrenic nerve reconstruction under complete video-assisted thoracic surgery, and with minimal additional stress to the patient. This study sought to ascertain the utility of this procedure from an evaluation of the cases experienced to date. We performed 6 cases of complete video-assisted thoracic surgery phrenic nerve reconstruction from October 2009 to December 2013 in patients who had undergone phrenic nerve resection or separation to remove tumours en bloc. In all cases, it was difficult to separate the phrenic nerve from the tumour. Reconstruction involved direct anastomosis in 3 cases and intercostal nerve interposition anastomosis in the remaining 3 cases. In the 6 patients (3 men, 3 women; mean age 50.8 years), we performed two right-sided and four left-sided procedures. The mean anastomosis time was 5.3 min for direct anastomosis and 35.3 min for intercostal nerve interposition anastomosis. Postoperative phrenic nerve function was measured on chest X-ray during inspiration and expiration. Direct anastomosis was effective in 2 of the 3 patients, and intercostal nerve interposition anastomosis was effective in all 3 patients. Diaphragm function was confirmed on X-ray to be improved in these 5 patients. Complete video-assisted thoracic surgery phrenic nerve reconstruction was effective for direct anastomosis as well as for intercostal nerve interposition anastomosis in a small sample of selected patients. The procedure shows promise for phrenic nerve reconstruction and further data should be accumulated over time. © The

  11. Comparative evaluation of two reconstructive methods following laparoscopic assisted subtotal gastrectomy in dogs

    Directory of Open Access Journals (Sweden)

    Bakhtiari Jalal

    2012-12-01

    Full Text Available Abstract Background Laparoscopic gastrectomy is a new and technically challenging surgical procedure with potential benefit. The objective of this study was to investigate clinical and para-clinical consequences following Roux-en-Y and Jejunal Loop interposition reconstructive techniques for subtotal gastrectomy using laparoscopic assisted surgery. Results Following resection of the stomach attachments through a laparoscopic approach, stomach was removed and reconstruction was performed with either standard Roux-en-Y (n = 5 or Jejunal Loop interposition (n = 5 methods. Weight changes were monitored on a daily basis and blood samples were collected on Days 0, 7 and 21 post surgery. A fecal sample was collected on Day 28 after surgery to evaluate fat content. One month post surgery, positive contrast radiography was conducted at 5, 10, 20, 40, 60 and 90 minutes after oral administration of barium sulfate, to evaluate the postoperative complications. There was a gradual decline in body weight in both experimental groups after surgery (P  0.05. Fecal fat content increased in the Roux-en-Y compared to the Jejunal loop interposition technique (P  0.05. Conclusion Roux-en-Y and Jejunal loop interposition techniques might be considered as suitable approaches for reconstructing gastro-intestinal tract following gastrectomy in dogs. The results of this study warrant further investigation with a larger number of animals.

  12. Modified T-Plate Interpositional Arthroplasty for Temporomandibular Joint Ankylosis: A New and Versatile Option

    Directory of Open Access Journals (Sweden)

    Imran Ahmad

    2015-11-01

    Full Text Available BackgroundThis study has been conducted with the aim of evaluating modified T-plate interpositional arthroplasty.MethodsA prospective comparative study in patients admitted with temporomandibular joint ankylosis. Ankylotic temporomandibular joint arthroplasty included condylectomy gap arthroplasty in 7, temporalis muscle flap interpositional arthroplasty in 8, and modified T-plate interpositional arthroplasty in 13 cases. The patients were followed for three years. Collected data were tabulated and subjected to Fisher's exact test, chi-square test and probability estimation.ResultsA significant increase in interincisal distance of 32 mm was seen in 12 (92.31% patients in the T-plate interposition group, in 2 (25% cases of the temporalis muscle flap interposition group, and in 1 case (14.28% of the condylectomy group at 12, 24, and 36 months. Re-ankylosis was observed in 1 case (9.69% of the T-plate interposition group, while as it was observed in 4 (50% cases in the temporalis muscle flap interposition group and 4 (57.14% cases in the condylectomy group, and these differences were statistically significant.ConclusionsOur clinical experience with the use of the T-plate over the past 5 years has been encouraging, and our physiotherapy technique is quite simple. Even illiterate parents can assess it easily. Hence, we recommend this easy technique that does not damage the temporalis muscle for the management of temporomandibular joint ankylosis.

  13. Outcome of different facial nerve reconstruction techniques

    OpenAIRE

    Mohamed, Aboshanif; Omi, Eigo; Honda, Kohei; Suzuki, Shinsuke; Ishikawa, Kazuo

    2016-01-01

    Abstract Introduction: There is no technique of facial nerve reconstruction that guarantees facial function recovery up to grade III. Objective: To evaluate the efficacy and safety of different facial nerve reconstruction techniques. Methods: Facial nerve reconstruction was performed in 22 patients (facial nerve interpositional graft in 11 patients and hypoglossal-facial nerve transfer in another 11 patients). All patients had facial function House-Brackmann (HB) grade VI, either caused by...

  14. Vertical augmentation of the posterior atrophic mandible by interpositional grafts in a split-mouth design: a human tomography evaluation pilot study.

    Science.gov (United States)

    Domingues, Eduardo Pinheiro; Ribeiro, Rafael Fernandes; Horta, Martinho Campolina Rebello; Manzi, Flávio Ricardo; Côsso, Maurício Greco; Zenóbio, Elton Gonçalves

    2017-10-01

    Using computed tomography, to compare vertical and volumetric bone augmentation after interposition grafting with bovine bone mineral matrix (GEISTLICH BIO-OSS ® ) or hydroxyapatite/tricalcium phosphate (STRAUMANN ® BONECERAMIC) for atrophic posterior mandible reconstruction through segmental osteotomy. Seven patients received interposition grafts in the posterior mandible for implant rehabilitation. The computed tomography cone beam images were analysed with OsiriX Imaging Software 6.5 (Pixmeo Geneva, Switzerland) in the pre-surgical period (T0), at 15 days post-surgery (T1) and at 180 days post-surgery (T2). The tomographic analysis was performed by a single trained and calibrated radiologist. Descriptive statistics and nonparametric methods were used to analyse the data. There was a significant difference in vertical and volume augmentation with both biomaterials using the technique (P  0.05) in volume change of the graft, bone volume augmentation, or augmentation of the maximum linear vertical distance between the two analysed biomaterials. The GEISTLICH BIO-OSS ® and STRAUMANN ® BONECERAMIC interposition grafts exhibited similar and sufficient dimensional stability and volume gain for short implants in the atrophic posterior mandible. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Interposition of the gallbladder in the common hepatic duct: a rare dangerous anomaly. Case report.

    Science.gov (United States)

    Rosato, L; Ginardi, A; Mondini, G

    2011-01-01

    Anomalies of the gallbladder position in the biliary tract are rare, but they could be very dangerous during cholecystectomy. A 48-year-old man presented with a 2-week history of intermittent epigastric pain, scleral jaundice and elevation of liver function tests. After a magnetic resonance cholangiogram and an endoscopic retrograde cholangiogram with sphincterotomy, he was submitted to laparoscopic cholecystectomy, the conversion to laparotomy was decided for the suspect of gallbladder interposition. The anatomical anomaly was confirmed and a Roux-en-Y hepaticojejunostomy was executed, with end-to-side anastomosis between the confluence of the hepatic ducts and the fourth loop of jejunum, on a biliary stent. This catheter was removed in the tenth postoperative day; after cholangiography and CT abdominal scan the patient was discharged, without complications. The gallbladder interposition is a rare malformation which seems to arise from an embryonic anomaly occurring between the 4th and the 5th week and whose potential causes have not been detected. A similar outcome could be also determined by a Mirizzi syndrome, but in our case it is excluded because intra-operatively there was no inflammatory reaction that could justify the presence of a fistula between the gallbladder and the common hepatic duct. Once the gallbladder interposition is found, the surgical treatment consists in removing the gallbladder itself and the corresponding part of the common hepatic duct. The reconstruction is carried out by a Roux-en-Y hepaticojejunostomy with anastomosis at the hepatic hilum, positioning a biliary stent.

  16. Freeze-dried allograft-mediated gene or protein delivery of growth and differentiation factor 5 reduces reconstructed murine flexor tendon adhesions

    DEFF Research Database (Denmark)

    Svensson, Sys Hasslund; Dadali, Tulin; Ulrich-Vinther, Michael

    2014-01-01

    reverse transcription polymerase chain reaction (RT-PCR), enzyme-linked immunosorbent assay (ELISA), and in vivo bioluminescent imaging. We then reconstructed flexor digitorum longus (FDL) tendons of the mouse hindlimb with allografts loaded with low and high doses of recombinant GDF-5 protein and r......Advances in allograft processing have opened new horizons for clinical adaptation of flexor tendon allografts as delivery scaffolds for antifibrotic therapeutics. Recombinant adeno-associated-virus (rAAV) gene delivery of the growth and differentiation factor 5 (GDF-5) has been previously...... associated with antifibrotic effects in a mouse model of flexor tendoplasty. In this study, we compared the effects of loading freeze-dried allografts with different doses of GDF-5 protein or rAAV-Gdf5 on flexor tendon healing and adhesions. We first optimized the protein and viral loading parameters using...

  17. Semitendinosus Tendon for Solitary Use in Anterior Cruciate ...

    African Journals Online (AJOL)

    The ANNALS of AFRICAN SURGERY | www.annalsofafricansurgery.com. The ANNALS of ... knee instability. Tendon allografts and autografts have been used successfully to reconstruct a torn. ACL. However, allografts have been associated with a higher rate of failure .... Semitendinosus Tendon to Prevent a. Postoperative ...

  18. Mechanoactive scaffold induces tendon remodeling and expression of fibrocartilage markers.

    Science.gov (United States)

    Spalazzi, Jeffrey P; Vyner, Moira C; Jacobs, Matthew T; Moffat, Kristen L; Lu, Helen H

    2008-08-01

    Biological fixation of soft tissue-based grafts for anterior cruciate ligament (ACL) reconstruction poses a major clinical challenge. The ACL integrates with subchondral bone through a fibrocartilage enthesis, which serves to minimize stress concentrations and enables load transfer between two distinct tissue types. Functional integration thus requires the reestablishment of this fibrocartilage interface on reconstructed ACL grafts. We designed and characterized a novel mechanoactive scaffold based on a composite of poly-alpha-hydroxyester nanofibers and sintered microspheres; we then used the scaffold to test the hypothesis that scaffold-induced compression of tendon grafts would result in matrix remodeling and the expression of fibrocartilage interface-related markers. Histology coupled with confocal microscopy and biochemical assays were used to evaluate the effects of scaffold-induced compression on tendon matrix collagen distribution, cellularity, proteoglycan content, and gene expression over a 2-week period. Scaffold contraction resulted in over 15% compression of the patellar tendon graft and upregulated the expression of fibrocartilage-related markers such as Type II collagen, aggrecan, and transforming growth factor-beta3 (TGF-beta3). Additionally, proteoglycan content was higher in the compressed tendon group after 1 day. The data suggest the potential of a mechanoactive scaffold to promote the formation of an anatomic fibrocartilage enthesis on tendon-based ACL reconstruction grafts.

  19. Tensile strength comparison between peroneus longus and hamstring tendons: A biomechanical study

    Directory of Open Access Journals (Sweden)

    Rudy

    2017-01-01

    Conclusion: The tensile strength of the peroneus longus tendon, which is similar to that of hamstring, gives information that both have the same biomechanic properties. Peroneus longus should not be used as a first option in ACL reconstruction, but may be used as an alternative donor in cases involving multiple instability that require more tendon donors in the reconstruction.

  20. Silicone infusion tubing instead of Hunter rods for two-stage zone 2 flexor tendon reconstruction in a resource-limited surgical environment.

    Science.gov (United States)

    Kibadi, K; Moutet, F

    2017-10-01

    The authors describe their experience using silicone infusion tubing in place of Hunter rods for two-stage zone 2 flexor tendon reconstruction in a resource-limited surgical environment. This case report features a 47-year-old, right-handed man who had no active PIP and DIP joint flexion in four fingers of the right hand 5 months after an injury. During the first repair stage, the A2 and A4 pulleys were reconstructed using an extensor retinaculum graft. An infusion tube was inserted instead of Hunter rods. During the second stage, formation of a digital neo-canal around the infusion tubing was observed. The infusion tubing was removed and replaced with a palmaris longus tendon graft according to the conventional technique. Physiotherapy and rehabilitation followed surgery. At 6 months, very significant progress had been made with complete recovery of PIP and DIP flexion in the four fingers. Copyright © 2017 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  1. Use of a strontium-enriched calcium phosphate cement in accelerating the healing of soft-tissue tendon graft within the bone tunnel in a rabbit model of anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Kuang, G M; Yau, W P; Lu, W W; Chiu, K Y

    2013-07-01

    We investigated whether strontium-enriched calcium phosphate cement (Sr-CPC)-treated soft-tissue tendon graft results in accelerated healing within the bone tunnel in reconstruction of the anterior cruciate ligament (ACL). A total of 30 single-bundle ACL reconstructions using tendo Achillis allograft were performed in 15 rabbits. The graft on the tested limb was treated with Sr-CPC, whereas that on the contralateral limb was untreated and served as a control. At timepoints three, six, nine, 12 and 24 weeks after surgery, three animals were killed for histological examination. At six weeks, the graft-bone interface in the control group was filled in with fibrovascular tissue. However, the gap in the Sr-CPC group had already been completely filled in with new bone, and there was evidence of the early formation of Sharpey fibres. At 24 weeks, remodelling into a normal ACL-bone-like insertion was found in the Sr-CPC group. Coating of Sr-CPC on soft tissue tendon allograft leads to accelerated graft healing within the bone tunnel in a rabbit model of ACL reconstruction using Achilles tendon allograft.

  2. Initial experience with visualizing hand and foot tendons by dual-energy computed tomography.

    Science.gov (United States)

    Deng, Kai; Sun, Cong; Liu, Cheng; Ma, Rui

    2009-01-01

    To assess the feasibility of visualizing hand and foot tendons by dual-energy computed tomography (CT). Twenty patients who suffered from hand or feet pains were scanned on dual-source CT (Definition, Forchheim, Germany) with dual-energy mode at tube voltages of 140 and 80 kV and a corresponding ratio of 1:4 between tube currents. The reconstructed images were postprocessed by volume rendering techniques (VRT) and multiplanar reconstruction (MPR). All of the suspected lesions were confirmed by surgery or follow-up studies. Twelve patients (total of 24 hands and feet, respectively) were found to be normal and the other eight patients (total of nine hands and feet, respectively) were found abnormal. Dual-energy techniques are very useful in visualizing tendons of the hands and feet, such as flexor pollicis longus tendon, flexor digitorum superficialis/profundus tendon, Achilles tendon, extensor hallucis longus tendon, and extensor digitorum longus tendon, etc. It can depict the whole shape of the tendons and their fixation points clearly. Peroneus longus tendon in the sole of the foot was not displayed very well. The distal ends of metacarpophalangeal joints with extensor digitoium tendon and extensor pollicis longus tendon were poorly shown. The lesions of tendons such as the circuitry, thickening, and adherence were also shown clearly. Dual-energy CT offers a new method to visualize tendons of the hand and foot. It could clearly display both anatomical structures and pathologic changes of hand and foot tendons.

  3. Treatment of giant and large fusiform middle cerebral artery aneurysms with excision and interposition radial artery graft in a 4-year-old child: case report.

    Science.gov (United States)

    Mrak, Goran; Paladino, Josip; Stambolija, Vasilije; Nemir, Jakob; Sekhar, Laligam N

    2014-03-01

    We report an unusual case of complex giant and large fusiform aneurysms not amenable for clipping or coiling in a 4-year-old child managed with aneurysm resection and radial artery interposition graft. A 4-year-old child presented with repeated severe headache and vomiting. Computed tomography, magnetic resonance imaging, and magnetic resonance angiography and digital subtraction angiography showed a giant fusiform aneurysm on the right middle cerebral artery (MCA). Because of the complex shape, endovascular treatment or clip reconstruction was not possible, and a bypass procedure was planned. Right frontotemporal craniotomy and orbitotomy was performed. Two aneurysms involving the M1 segment of the MCA were found in line, 1 giant, and the other large in size. The aneurysms were resected and treated with short radial artery interposition graft, which was narrower than the proximal or distal MCA. The child recovered normally, and the bypass was patent after 1 year. Large fusiform MCA aneurysms may be difficult to treat, but there are treatment options that include a bypass procedure. Resection and short interposition radial artery graft is an excellent but rare treatment option in a very young child. This was a very successful treatment in this child.

  4. [Excision of accessory navicular with reconstruction of posterior tibial tendon insertion on navicular for treatment of flatfoot related with accessory navicular].

    Science.gov (United States)

    Cao, Honghui; Tang, Kanglai; Deng, Yinshuan; Tan, Xiaokang; Zhou, Binghua; Tao, Xu; Chen, Lei; Chen, Qianbo

    2012-06-01

    To analyze the excision of accessory navicular with reconstruction of posterior tibial tendon insertion on navicular for the treatment of flatfoot related with accessory navicular and to evaluate its effectiveness. Between May 2006 and June 2011, 33 patients (40 feet) with flatfoot related with accessory navicular were treated. There were 14 males (17 feet) and 19 females (23 feet) with an average age of 30.1 years (range, 16-56 years). All patients had bilateral accessory navicular; 26 had unilateral flatfoot and 7 had bilateral flatfeet. The disease duration ranged from 7 months to 9 years (median, 24 months). The American Orthopaedic Foot and Ankle Society (AOFAS) ankle-midfoot score was 47.9 +/- 7.3. The X-ray films showed type II accessory navicular, the arch height loss, and heel valgus in all patients. All of them received excision of accessory navicular and reconstruction of posterior tibial tendon insertion on navicular with anchor. All patients got primary wound healing without any complication. Thirty patients (36 feet) were followed up 6-54 months with an average of 23 months. All patients achieved complete pain relief at 6 months after surgery and had good appearance of the feet. The AOFAS ankle-midfoot score was 90.4 +/- 2.0 at last follow-up, showing significant difference when compared with preoperative score (t=29.73, P=0.00). X-ray films showed that no screw loosening or breakage was observed. There were significant differences in the arch height, calcaneus inclination angle, talocalcaneal angle, and talar-first metatarsal angle between pre-operation and last follow-up (P < 0.01). The excision of accessory navicular with reconstruction of posterior tibial tendon insertion on navicular is a good choice for the treatment of flatfoot related with accessory navicular, with correction of deformity, excellent effectiveness, and less complications.

  5. Variation in the insertion of the palmaris longus tendon

    Science.gov (United States)

    Sunil, Vinutha; Rajanna, Shubha; Gitanjali; Kadaba, Jayanthi

    2015-01-01

    The palmaris longus is harvested as a tendon graft in various surgical procedures. We herein report the variations in the insertion of the palmaris longus tendon. During a routine dissection, a rare variation in the insertion of the palmaris longus tendon was observed. In the left forearm, the palmaris longus tendon bifurcated, while in the right forearm, the palmaris longus tendon trifurcated, giving rise to an accessory muscle, which passed superficial to the ulnar artery and ulnar nerve. The accessory muscle was supplied by a deep branch of the ulnar nerve, and the ulnar artery was observed to be tortuous. During reconstructive surgeries, surgeons should bear in mind the accessory muscle. Also, since the palmaris longus muscle provides a very useful graft in tendon surgery, every surgeon should be aware of the variations in the insertion of the palmaris longus tendon. PMID:25640108

  6. Glenohumeral kinematics after soft tissue interposition graft and glenoid reaming: A cadaveric study

    Directory of Open Access Journals (Sweden)

    Nickolas G Garbis

    2016-01-01

    Conclusion: Glenohumeral contact pressure is significantly improved with interposition of allograft at time zero compared to an arthritic state. Our findings suggest that concentric reaming did not differ from the arthritic model when compared to normal. These findings favor the use of allograft for interposition as a potential treatment option in patients with glenoid wear.

  7. Knee flexor strength recovery following hamstring tendon harvest for anterior cruciate ligament reconstruction: a systematic review

    Directory of Open Access Journals (Sweden)

    Clare Ardern

    2009-07-01

    Full Text Available The hamstring tendons are an increasingly popular graft choice for anterior cruciate ligament reconstruction due to preservation of quadriceps function and the absence of anterior knee pain post-operatively. Two commonly used hamstring grafts are a quadruple strand semitendinosus graft (4ST and a double strand semitendinosus-double strand gracilis graft (2ST-2G. It has been suggested that concurrent harvest of the semitendinsous and gracilis tendons may result in sub-optimal hamstring strength recovery as the gracilis may play a role in reinforcing the semitendinosus particularly in deep knee flexion angles. The objective of this systematic review was to synthesize the findings of available literature and determine whether semitendinosus and gracilis harvest lead to post-operative hamstring strength deficits when compared to semitendinosus harvest alone. Seven studies were identified which compared hamstring strength outcomes between the common hamstring graft types. The methodological quality of each paper was assessed, and where possible effect sizes were calculated to allow comparison of results across studies. No differences were reported between the groups in isokinetic hamstring strength. Deficits in hamstring strength were reported in the 2ST-2G groups when compared to the 4ST groups in isometric strength testing at knee flexion angles ≥70°, and in the standing knee flexion angle. Preliminary evidence exists to support the hypothesis that harvesting the semitendinosus tendon alone is preferable to harvesting in combination with the gracilis tendon for minimizing post-operative hamstring strength deficits at knee flexion angles greater than 70°. However, due to the paucity of research comparing strength outcomes between the common hamstring graft types, further investigation is warranted to fully elucidate the implications for graft harvest.

  8. Talocalcaneal Joint Middle Facet Coalition Resection With Interposition of a Juvenile Hyaline Cartilage Graft.

    Science.gov (United States)

    Tower, Dyane E; Wood, Ryan W; Vaardahl, Michael D

    2015-01-01

    Talocalcaneal joint middle facet coalition is the most common tarsal coalition, occurring in ≤2% of the population. Fewer than 50% of involved feet obtain lasting relief of symptoms after nonoperative treatment, and surgical intervention is commonly used to relieve symptoms, increase the range of motion, improve function, reconstruct concomitant pes planovalgus, and prevent future arthrosis from occurring at the surrounding joints. Several approaches to surgical intervention are available for patients with middle facet coalitions, ranging from resection to hindfoot arthrodesis. We present a series of 4 cases, in 3 adolescent patients, of talocalcaneal joint middle facet coalition resection with interposition of a particulate juvenile hyaline cartilaginous allograft (DeNovo(®) NT Natural Tissue Graft, Zimmer, Inc., Warsaw, IN). With a mean follow-up period of 42.8 ± 2.9 (range 41 to 47) months, the 3 adolescent patients in the present series were doing well with improved subtalar joint motion and decreased pain, and 1 foot showed no bony regrowth on a follow-up computed tomography scan. The use of a particulate juvenile hyaline cartilaginous allograft as interposition material after talocalcaneal middle facet coalition resection combined with adjunct procedures to address concomitant pes planovalgus resulted in good short-term outcomes in 4 feet in 3 adolescent patients. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  9. [Reconstruction of medial patellofemoral ligament with transposition of great adductor muscular tendon for the treatment of teenagers' recurrent patellar dislocation].

    Science.gov (United States)

    Shao, Chuan-Qiang; Chen, Chang-Chun; Zhao, Chun-Cheng; Yang, Hong-Mei; Kang, Yan-Zhong

    2017-06-25

    To investigate surgical method and clinical curative effects of medial patellofemoral ligament (MPFL) reconstruction with great adductor muscular tendon in treating teenagers' recurrent patellar dislocation. From May 2012 to September 2014, 19 patients with recurrent dislocation of patellar, including 6 males and 13 females with an average of 16 years old (ranged from 13 to 17 years), the courses of disease ranged from 3 to 18 months(averaged 6 months). All patients were underwent great adductor muscular tendon transposition to reconstruct medial patellofemoral ligament. The curative effects were evaluated by preoperative and postoperative with Lysholm scores and Patellofemoral angle and Q angle. All patients were followed up from 12 to 18 months with an average of 16.5 months. Primary healing was achieved at stage I. No pain, swelling and patellar dislocation or subluxation occurred. Patellofemoral angle increased from preoperative (-3.8±4.9)° to (10.3±4.1)° postoperatively. Q angle decreased from preoperative(16.4±3.1)° to(10.5±1.2)° postoperatively; Lysholm scores were improved from preoperative (68.6±8.5) to (93.7±6.5) final follow-up ( P teenagers' recurrent patellar dislocation.

  10. In Vivo Study of Ligament-Bone Healing after Anterior Cruciate Ligament Reconstruction Using Autologous Tendons with Mesenchymal Stem Cells Affinity Peptide Conjugated Electrospun Nanofibrous Scaffold

    Directory of Open Access Journals (Sweden)

    Jingxian Zhu

    2013-01-01

    Full Text Available Electrospinning nanofibrous scaffold was commonly used in tissue regeneration recently. Nanofibers with specific topological characteristics were reported to be able to induce osteogenic differentiation of MSCs. In this in vivo study, autologous tendon grafts with lattice-like nanofibrous scaffold wrapping at two ends of autologous tendon were used to promote early stage of ligament-bone healing after rabbit ACL reconstruction. To utilize native MSCs from bone marrow, an MSCs specific affinity peptide E7 was conjugated to nanofibrous meshes. After 3 months, H-E assessment and specific staining of collagen type I, II, and III showed direct ligament-bone insertion with typical four zones (bone, calcified fibrocartilage, fibrocartilage, and ligament in bioactive scaffold reconstruction group. Diameters of bone tunnel were smaller in nanofibrous scaffold conjugated E7 peptide group than those in control group. The failure load of substitution complex also indicated a stronger ligament-bone insertion healing using bioactive scaffold. In conclusion, lattice-like nanofibrous scaffold with specific MSCs affinity peptide has great potential in promoting early stage of ligament-bone healing after ACL reconstruction.

  11. Anterior cruciate ligament reconstruction using bone plug-free quadriceps tendon autograft: intermediate-term clinical outcome after 24–36 months

    Directory of Open Access Journals (Sweden)

    Schulz AP

    2013-11-01

    Full Text Available Arndt P Schulz,1 Vivien Lange,2 Justus Gille,1 Christine Voigt,3 Susanne Fröhlich,4 Markus Stuhr,1 Christian Jürgens5 1Department of Orthopedics, Trauma, and Sports Medicine, University Hospital Lübeck, Lübeck, Germany; 2Department of Rehabilitation, Sana Regio Klinikum, Wedel, Germany; 3Department of Sports Medicine and Arthroscopy, Diakoniekrankenhaus Friederikenstift, Hannover, Germany; 4Department of Orthopedics, University of Rostock, Rostock, Germany; 5Department of Orthopedics, Trauma, and Sports Medicine, BG Trauma Hospital Hamburg, Hamburg, Germany Introduction: Although known as a possible graft option for decades, quadriceps tendon grafts have often been termed a second-line graft option. We report a consecutive case series using this method as the primary treatment line. The rationale for this study was to evaluate the midterm results of this method in a prospective and consecutive case series. The primary study question was to determine the clinical results 24–36 months after primary anterior cruciate ligament (ACL reconstruction using a bone plug-free quadriceps tendon autograft fixed with bioabsorbable cross-pins. Materials and methods: The study population included 55 patients, of whom 24 were female (43.6%. The mean age at the index procedure was 31.7 years (15–58 years. All patients received an ACL construction using a bone block-free quadriceps tendon graft fixed with resorbable cross-pins. The postoperative regimen included partial weight-bearing for 3 weeks and flexion limited to 90° for six weeks; an orthosis was not used. The mean follow-up duration was 29.5 months (24.3–38.5 months after the index procedure. The International Knee Documentation Committee (IKDC subjective score and examination form was assessed, as well as the Lysholm and Gillquist score and the Tegner activity index. The Rolimeter arthrometer was used to assess the anterior laxity of the knee. Results: Graft harvesting was possible in all cases

  12. All-Inside Single-Bundle Reconstruction of the Anterior Cruciate Ligament with the Anterior Half of the Peroneus Longus Tendon Compared to the Semitendinosus Tendon: A Two-Year Follow-Up Study.

    Science.gov (United States)

    Bi, Mingguang; Zhao, Chen; Zhang, Shuijun; Yao, Bin; Hong, Zheping; Bi, Qing

    2018-02-08

    The anterior half of the peroneus longus tendon (AHPLT) has been reported to be acceptable for ligament reconstruction with respect to strength and safety. However, there is little information regarding the clinical outcomes after using the AHPLT compared with other autograft tendons. A prospective randomized controlled study was performed to compare the results of 62 cases of all-inside anatomical single-bundle anterior cruciate ligament (ACL) reconstruction using the AHPLT and 62 cases using semitendinosus graft with an average of 30.0 ± 3.6 months' follow-up. Tunnel placements of enrolled cases were measured on three-dimensional (3D) computed tomography (CT) and X-ray imaging. Knee stability was assessed using the anterior drawer test, pivot shift test, and KT-1000. The International Knee Documentation Committee (IKDC) 2000 subjective score was used to evaluate functional outcomes. The American Orthopedic Foot and Ankle Score (AOFAS) and the assessment of eversion muscle strength were performed to evaluate the function of the ankle donor site. Tunnel positions, which were confirmed with 3D CT, were in the anatomical positions. At the final follow-up, there were no significant differences between the semitendinosus group and the AHPLT group in the IKDC score (90.4 ± 7.1 vs. 89.3. ± 8.4), KT 1000 measurements (1.71 ± 0.57 vs. 1.85 ± 0.77), pivot shift test, and Visual Analogue Scale (VAS) (0.15 ± 0.36 vs. 0.10 ± 0.30). No obvious ankle site complications were found at 24 months. The average AOFAS score of the AHPLT group was comparable to that of the semitendinosus tendon group (99.1 ± 1.40 vs. 99.5 ± 1.21). There was no significant difference in clinical outcomes or knee stability between the semitendinosus group and the AHPLT group at the 2-year follow-up. An AHPLT autograft may be a good alternative for all-inside ACL reconstruction with respect to its strength, safety, and donor site morbidity. Thieme Medical

  13. Transportal anterior cruciate ligament reconstruction with quadrupled hamstring tendon graft: A prospective outcome study

    Directory of Open Access Journals (Sweden)

    Chandan Kumar

    2017-01-01

    Full Text Available Background: Anterior cruciate ligament (ACL reconstruction has been one of the most commonly performed procedures throughout the world. Unsatisfactory outcome with conventional ACL reconstruction has been attributed to nonanatomic graft placement. Researchers have advised placing the graft in the native footprint of ACL to avoid nonanatomic graft placement. The goal of this study was to analyze the outcome of anatomic single bundle ACL reconstruction using transportal technique. Materials and Methods: This was a prospective outcome study conducted on 85 consecutive patients of ACL reconstruction of which 62 patients met inclusion and exclusion criteria and were analyzed for final results. All the patients underwent ACL reconstruction by quadrupled hamstring tendon graft using transportal technique and the accessory anteromedial (AAM portal for femoral tunnel creation. The graft was fixed with endobutton on femoral side and bioabsorbable screw on the tibial side. Patients were evaluated for range of motion, International Knee Documentation Committee (IKDC score, and Lysholm scores at a minimum followup period of 2 years. The mean pre- and postoperative scores were compared using Wilcoxon signed-rank test. Results: The mean Lysholm and IKDC scores improved significantly (P < 0.0001 from preoperative value. According to IKDC score, 90.3% (n = 56 were either normal or near normal at final followup. According to Lysholm score, 75.8% of patients had excellent and 13.3% had good results. Preoperatively, pivot shift was present in 85.5% (n = 53 of patients which reduced to 4.8% (n = 3 postoperatively. Infection and knee stiffness occurred in two patients, and femoral tunnel blowout and graft re-rupture occurred in one patient each. Conclusion: Anatomic ACL reconstruction by AAM portal is a reproducible technique which gives good clinical outcome at short-term followup.

  14. Assessment of rotatory instability after anterior cruciate ligament reconstruction with a bone-patellar tendon-bone graft

    International Nuclear Information System (INIS)

    Tashiro, Yasutaka; Okazaki, Ken; Miura, Hiromasa

    2010-01-01

    Anatomically oriented anterior cruciate ligament (ACL) reconstruction has been advocated recently, but its effect on rotatory instability remains to be cleared objectively. The purpose of this study was to quantitatively evaluate rotatory instability in ACL reconstructed knees with a bone-patellar tendon-bone (BTB) graft using an open MRI system. Eighteen subjects underwent arthroscopic ACL reconstruction with a BTB graft. The tibial tunnel was placed in the center of the ACL footprint. The femoral tunnel was drilled transtibially at the 10:00 to 10:30-o'clock position for the right knees. Subjects were examined using a Slocum anterolateral rotatory instability test in open MRI. Anterior tibial translation was measured at the medial and lateral compartments by evaluating sagittal images. Anterior knee stability was evaluated using the KT-2000 arthrometer. The clinical knee function was assessed with the Lysholm and Tegner scoring scales before and after the surgery. Side-to-side differences of anterolateral tibial translation was 0.1 mm. Side-to-side difference on KT-2000 arthrometer measurement was 1.8 mm. The Lysholm score improved to 96 and the latest Tegner score reached substantially the preinjury level. ACL reconstruction with a BTB graft was successful in restoring rotatory stability as well as anterior stability and knee function. (author)

  15. Isokinetic evaluation of internal/external tibial rotation strength after the use of hamstring tendons for anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Armour, Tanya; Forwell, Lorie; Litchfield, Robert; Kirkley, Alexandra; Amendola, Ned; Fowler, Peter J

    2004-01-01

    Evaluation of the knee after an anterior cruciate ligament reconstruction with the use of the semitendinosus and gracilis (hamstring) autografts has primarily focused on flexion and extension strength. The semitendinosus and gracilis muscles contribute to internal tibial rotation, and it has been suggested that harvest of these tendons for the purpose of an anterior cruciate ligament reconstruction contributes to internal tibial rotation weakness. Internal tibial rotation strength may be affected by the semitendinosus and gracilis harvest after anterior cruciate ligament reconstruction. Prospective evaluation of internal and external tibial rotation strength. Inclusion criteria for subjects (N = 30): unilateral anterior cruciate ligament reconstruction at least 2 years previously, a stable anterior cruciate ligament (problems after initial knee reconstruction, a normal contralateral knee, and the ability to comply with the testing protocol. In an attempt to minimize unwanted subtalar joint motion, subjects were immobilized using an ankle brace and tested at angular velocities of 60 degrees /s, 120 degrees /s, and 180 degrees /s at a knee flexion angle of 90 degrees . The mean peak torque measurements for internal rotation strength of the operative limb (60 degrees /s, 17.4 +/- 4.5 ft-lb; 120 degrees /s, 13.9 +/- 3.3 ft-lb; 180 degrees /s, 11.6 +/- 3.0 ft-lb) were statistically different compared to the nonoperated limb (60 degrees /s, 20.5 +/- 4.7 ft-lb; 120 degrees /s, 15.9 +/- 3.8 ft-lb; 180 degrees /s, 13.4 +/- 3.8 ft-lb) at 60 degrees /s (P = .012), 120 degrees /s (P = .036), and 180 degrees /s (P = .045). The nonoperative limb demonstrated greater strength at all speeds. The mean torque measurements for external rotation were statistically similar when compared to the nonoperated limb at all angular velocities. We have shown through our study that patients who undergo surgical intervention to repair a torn anterior cruciate ligament with the use of autogenous

  16. Two-stage reconstruction with the modified Paneva-Holevich technique.

    LENUS (Irish Health Repository)

    O'Shea, Kieran

    2013-05-01

    Flexor tendon reconstruction poses both a technical challenge to the hand surgeon and a rehabilitative challenge to the patient and therapist. The modified Paneva-Holevich technique, using a pedicled intra-synovial graft, is a safe and reliable means of staged flexor tendon reconstruction, offering a number of theoretical advantages over classic free-tendon grafting techniques. Clinical outcomes are at the least comparable, if not superior, to those achieved following free-tendon techniques with most authors reporting a low requirement for third stage tenolysis.

  17. Anterior cruciate ligament reconstruction using bone plug-free quadriceps tendon autograft: intermediate-term clinical outcome after 24-36 months.

    Science.gov (United States)

    Schulz, Arndt P; Lange, Vivien; Gille, Justus; Voigt, Christine; Fröhlich, Susanne; Stuhr, Markus; Jürgens, Christian

    2013-01-01

    Although known as a possible graft option for decades, quadriceps tendon grafts have often been termed a second-line graft option. We report a consecutive case series using this method as the primary treatment line. The rationale for this study was to evaluate the midterm results of this method in a prospective and consecutive case series. The primary study question was to determine the clinical results 24-36 months after primary anterior cruciate ligament (ACL) reconstruction using a bone plug-free quadriceps tendon autograft fixed with bioabsorbable cross-pins. The study population included 55 patients, of whom 24 were female (43.6%). The mean age at the index procedure was 31.7 years (15-58 years). All patients received an ACL construction using a bone block-free quadriceps tendon graft fixed with resorbable cross-pins. The postoperative regimen included partial weight-bearing for 3 weeks and flexion limited to 90° for six weeks; an orthosis was not used. The mean follow-up duration was 29.5 months (24.3-38.5 months) after the index procedure. The International Knee Documentation Committee (IKDC) subjective score and examination form was assessed, as well as the Lysholm and Gillquist score and the Tegner activity index. The Rolimeter arthrometer was used to assess the anterior laxity of the knee. Graft harvesting was possible in all cases; a bony extension was never required. On average, graft length was measured at 8.8 cm (7.5-10 cm). The mean IKDC subjective score at follow-up was 80.44 points (55.17-100 points, standard deviation [SD] 12.05). The mean preinjury Tegner activity index was 4.98 (2-7) compared to a mean value of 4.16 (2-7, SD 0.8) at follow-up. There was a mean loss of 0.82 index points. The average Lysholm and Gillquist score was 89 points (65-100, SD 17.7). Of the results, 89.1% were in the good or very good groups; in one case (1.8%), the result was poor, while the rest were fair. ACL reconstruction using a bone plug-free quadriceps tendon

  18. Stem Cell Applications in Tendon Disorders: A Clinical Perspective

    Directory of Open Access Journals (Sweden)

    Mark Young

    2012-01-01

    Full Text Available Tendon injuries are a common cause of morbidity and a significant health burden on society. Tendons are structural tissues connecting muscle to bone and are prone to tearing and tendinopathy, an overuse or degenerative condition that is characterized by failed healing and cellular depletion. Current treatments, for tendon tear are conservative, surgical repair or surgical scaffold reconstruction. Tendinopathy is treated by exercises, injection therapies, shock wave treatments or surgical tendon debridement. However, tendons usually heal with fibrosis and scar tissue, which has suboptimal tensile strength and is prone to reinjury, resulting in lifestyle changes with activity restriction. Preclinical studies show that cell therapies have the potential to regenerate rather than repair tendon tissue, a process termed tenogenesis. A number of different cell lines, with varying degrees of differentiation, have being evaluated including stem cells, tendon derived cells and dermal fibroblasts. Even though cellular therapies offer some potential in treating tendon disorders, there have been few published clinical trials to determine the ideal cell source, the number of cells to administer, or the optimal bioscaffold for clinical use.

  19. Tendon tissue engineering and its role on healing of the experimentally induced large tendon defect model in rabbits: a comprehensive in vivo study.

    Science.gov (United States)

    Meimandi-Parizi, Abdolhamid; Oryan, Ahmad; Moshiri, Ali

    2013-01-01

    Healing of large tendon defects is challenging. We studied the role of collagen implant with or without polydioxanone (PDS) sheath on the healing of a large Achilles tendon defect model, in rabbits. Sixty rabbits were divided into three groups. A 2 cm gap was created in the left Achilles tendon of all rabbits. In the control lesions, no implant was used. The other two groups were reconstructed by collagen and collagen-PDS implants respectively. The animals were clinically examined at weekly intervals and their lesions were observed by ultrasonography. Blood samples were obtained from the animals and were assessed for hematological analysis and determination of serum PDGF level, at 60 days post injury (DPI). The animals were then euthanized and their lesions were assessed for gross and histopathology, scanning electron microscopy, biomechanical testing, dry matter and hydroxyproline content. Another 65 pilot animals were also studied grossly and histopathologically to define the host implant interaction and graft incorporation at serial time points. The treated animals gained significantly better clinical scoring compared to the controls. Treatment with collagen and collagen-PDS implants significantly increased the biomechanical properties of the lesions compared to the control tendons at 60DPI (Ptendon. Implantation of the bioimplants had a significant role in initiating tendon healing and the implants were biocompatible, biodegradable and safe for application in tendon reconstructive surgery. The results of the present study may be valuable in clinical practice.

  20. Presence of Bacteria in Spontaneous Achilles Tendon Ruptures.

    Science.gov (United States)

    Rolf, Christer G; Fu, Sai-Chuen; Hopkins, Chelsea; Luan, Ju; Ip, Margaret; Yung, Shu-Hang; Friman, Göran; Qin, Ling; Chan, Kai-Ming

    2017-07-01

    The structural pathology of Achilles tendon (AT) ruptures resembles tendinopathy, but the causes remain unknown. Recently, a number of diseases were found to be attributed to bacterial infections, resulting in low-grade inflammation and progressive matrix disturbance. The authors speculate that spontaneous AT ruptures may also be influenced by the presence of bacteria. Bacteria are present in ruptured ATs but not in healthy tendons. Cross-sectional study; Level of evidence, 3. Patients with spontaneous AT ruptures and patients undergoing anterior cruciate ligament (ACL) reconstruction were recruited for this study. During AT surgical repair, excised tendinopathic tissue was collected, and healthy tendon samples were obtained as controls from hamstring tendon grafts used in ACL reconstruction. Half of every sample was reserved for DNA extraction and the other half for histology. Polymerase chain reaction (PCR) was conducted using 16S rRNA gene universal primers, and the PCR products were sequenced for the identification of bacterial species. A histological examination was performed to compare tendinopathic changes in the case and control samples. Five of 20 AT rupture samples were positive for the presence of bacterial DNA, while none of the 23 hamstring tendon samples were positive. Sterile operating and experimental conditions and tests on samples, controlling for harvesting and processing procedures, ruled out the chance of postoperative bacterial contamination. The species identified predominantly belonged to the Staphylococcus genus. AT rupture samples exhibited histopathological features characteristic of tendinopathy, and most healthy hamstring tendon samples displayed normal tendon features. There were no apparent differences in histopathology between the bacterial DNA-positive and bacterial DNA-negative AT rupture samples. The authors have demonstrated the presence of bacterial DNA in ruptured AT samples. It may suggest the potential involvement of bacteria

  1. Total esophagogastrectomy plus extended lymphadenectomy with transverse colon interposition: A treatment for extensive esophagogastric junction cancer

    OpenAIRE

    Ceroni, Marco; Norero, Enrique; Henríquez, Juan Pablo; Viñuela, Eduardo; Briceño, Eduardo; Martínez, Cristian; Aguayo, Gloria; Araos, Fernando; González, Paulina; Díaz, Alfonso; Caracci, Mario

    2015-01-01

    AIM: To review the post-operative morbidity and mortality of total esophagogastrectomy (TEG) with second barrier lymphadenectomy (D2) with interposition of a transverse colon and to determine the oncological outcomes of TEG D2 with interposition of a transverse colon.

  2. Ulcerative Colitis in Colonic Interposition for Esophageal Atresia

    OpenAIRE

    Arshad, Hafiz Muhammad Sharjeel; Tetangco, Eula; Elkhatib, Imad

    2016-01-01

    A 38-year-old male with a history of colonic interposition for esophageal atresia as an infant presented with dysphagia and abdominal pain. On the basis of endoscopy findings, pathology, and response to therapy, he was found to have ulcerative colitis of the colonic conduit.

  3. A surprise case of colonic interposition

    International Nuclear Information System (INIS)

    Law, Robert

    2006-01-01

    Blind nasogastric intubation failure as a result of changes to the normal anatomical pathway is not uncommon. This case report is of fluoroscopically guided intubation in a patient in whom blind intubation failed as a result of what was subsequently found to be a colonic interposition with associated late complications. Fluroscopically guided nasogastric intubation is a safe and effective procedure that should always be considered when blind intubation has failed

  4. Glenohumeral interposition of rotator cuff stumps: a rare complication of traumatic rotator cuff tear

    Directory of Open Access Journals (Sweden)

    Paulo Moraes Agnollitto

    2016-02-01

    Full Text Available Abstract The present report describes a case where typical findings of traumatic glenohumeral interposition of rotator cuff stumps were surgically confirmed. This condition is a rare complication of shoulder trauma. Generally, it occurs in high-energy trauma, frequently in association with glenohumeral joint dislocation. Radiography demonstrated increased joint space, internal rotation of the humerus and coracoid process fracture. In addition to the mentioned findings, magnetic resonance imaging showed massive rotator cuff tear with interposition of the supraspinatus, infraspinatus and subscapularis stumps within the glenohumeral joint. Surgical treatment was performed confirming the injury and the rotator cuff stumps interposition. It is important that radiologists and orthopedic surgeons become familiar with this entity which, because of its rarity, might be neglected in cases of shoulder trauma.

  5. Influence of the initial rupture size and tendon subregion on three-dimensional biomechanical properties of single-row and double-row rotator cuff reconstructions.

    Science.gov (United States)

    Lorbach, O; Pape, D; Raber, F; Busch, L C; Kohn, D; Kieb, M

    2012-11-01

    Influence of the initial rotator cuff tear size and of different subregions of the SSP tendon on the cyclic loading behavior of a modified single-row reconstruction compared to a suture-bridging double-row repair. Artificial tears (25 and 35 mm) were created in the rotator cuff of 24 human cadaver shoulders. The reconstructions were performed as a single-row repair (SR) using a modified suture configuration or a suture-bridge double-row repair (DR). Radiostereometric analysis was used under cyclic loading (50 cycles, 10–180 N, 10–250 N) to calculate cyclic displacement in three different planes (anteroposterior (x), craniocaudal (y) and mediolateral (z) level). Cyclic displacement was recorded, and differences in cyclic displacement of the anterior compared to the posterior subregions of the tendon were calculated. In small-to-medium tears (25 mm) and medium-to-large tears (35 mm), significant lower cyclic displacement was seen for the SR-reconstruction compared to the DR-repair at 180 N (p ≤ 0.0001; p = 0.001) and 250 N (p = 0.001; p = 0.007) in the x-level. These results were confirmed in the y-level at 180 N (p = 0.001; p = 0.0022) and 250 N (p = 0.005; p = 0.0018). Comparison of the initial tear sizes demonstrated significant differences in cyclic displacement for the DR technique in the x-level at 180 N (p = 0.002) and 250 N (p = 0.004). Comparison of the anterior versus the posterior subregion of the tendon revealed significant lower gap formation in the posterior compared to the anterior subregions in the x-level for both tested rotator cuff repairs (p ≤ 0.05). The tested single-row repair using a modified suture configuration achieved superior results in three-dimensional measurements of cyclic displacement compared to the tested double-row suture-bridge repair. The results were dependent on the initial rupture size of the rotator cuff tear. Furthermore, significant differences were found between tendon subregions of the rotator cuff with

  6. [Experimental study on co-culture of human fibroblasts on decellularized Achilles tendon].

    Science.gov (United States)

    Wang, Zhibing; Zhang, Xia; Guo, Xinyu; Qin, Chuan

    2013-07-01

    To investigate the preparation of decellularized Achilles tendons and the effect of co-culture of human fibroblasts on the scaffold so as to provide a scaffold for the tissue engineered ligament reconstruction. Achilles tendons of both hind limbs were harvested from 10 male New Zealand white rabbits (5-month-old; weighing, 4-5 kg). The Achilles tendons were decellularized using trypsin, Triton X-100, and sodium dodecyl sulfate (SDS), and then gross observation, histological examination, and scanning electron microscope (SEM) observation were performed; the human fibroblasts were seeded on the decellularized Achilles tendon, and then cytocompatibility was tested using the cell counting kit 8 method at 1, 3, 5, 7, and 9 days after co-culture. At 4 weeks after co-culture, SEM, HE staining, and biomechanical test were performed for observing cell-scaffold composite, and a comparison was made with before and after decellularization. After decellularization, the tendons had integrated aponeurosis and enlarged volume with soft texture and good toughness; there was no loose connective tissue and tendon cells between tendon bundles, the collagen fibers arranged loosely with three-dimensional network structure and more pores between tendon bundles; and it had good cytocompatibility. At 4 weeks after co-culture, cells migrated into the pores, and three-dimensional network structure disappeared. By biomechanical test, the tensile strength and Young's elastic modulus of the decellularized Achilles tendon group decreased significantly when compared with normal Achilles tendons group and cell-scaffold composite group (P Achilles tendons group and cell-scaffold composite group (P > 0.05). There was no significant difference in elongation at break among 3 groups (P > 0.05). The decellularized Achilles tendon is biocompatible to fibroblasts. It is suit for the scaffold for tissue engineered ligament reconstruction.

  7. Structured white light scanning of rabbit Achilles tendon.

    Science.gov (United States)

    Hayes, Alex; Easton, Katrina; Devanaboyina, Pavan Teja; Wu, Jian-Ping; Kirk, Thomas Brett; Lloyd, David

    2016-11-07

    The cross-sectional area (CSA) of a material is used to calculate stress under load. The mechanical behaviour of soft tissue is of clinical interest in the management of injury; however, measuring CSA of soft tissue is challenging as samples are geometrically irregular and may deform during measurement. This study presents a simple method, using structured light scanning (SLS), to acquire a 3D model of rabbit Achilles tendon in vitro for measuring CSA of a tendon. The Artec Spider™ 3D scanner uses structured light and stereophotogrammetry technologies to acquire shape data and reconstruct a 3D model of an object. In this study, the 3D scanner was integrated with a custom mechanical rig, permitting 360-degree acquisition of the morphology of six New Zealand White rabbit Achilles tendons. The reconstructed 3D model was then used to measure CSA of the tendon. SLS, together with callipers and micro-CT, was used to measure CSA of objects with a regular or complex shape, such as a drill flute and human cervical vertebra, for validating the accuracy and repeatability of the technique. CSA of six tendons was measured with a coefficient of variation of less than 2%. The mean CSA was 9.9±1.0mm 2 , comparable with those reported by other researchers. Scanning of phantoms demonstrated similar results to μCT. The technique developed in this study offers a simple and accurate method for effectively measuring CSA of soft tissue such as tendons. This allows for localised calculation of stress along the length, assisting in the understanding of the function, injury mechanisms and rehabilitation of tissue. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Biomechanical and immunohistochemical analysis of high hydrostatic pressure-treated Achilles tendons

    International Nuclear Information System (INIS)

    Diehl, P.; Steinhauser, E.; Gollwitzer, H.; Heister, C.; Schauwecker, J.; Schmitt, M.; Milz, S.; Mittelmeier, W.

    2006-01-01

    Reconstruction of bone defects caused by malignant tumors is carried out in different ways. At present, tumor-bearing bone segments are devitalized mainly by extracorporeal irradiation or autoclaving, but both methods have substantial disadvantages. In this regard, high hydrostatic pressure (HHP) treatment of the bone is a new, advancing technology that has been used in preclinical testing to inactivate normal cells and tumor cells without altering the biomechanical properties of the bone. The aim of this study was to examine the biomechanical and immunohistochemical properties of tendons after exposure to HHP and to evaluate whether preservation of the bony attachment of tendons and ligaments is possible. For this, 19 paired Achilles tendons were harvested from both hindlimbs of 4-month-old pigs. After preparation, the cross-sectional area of each tendon was determined by magnetic resonance imaging (MRI). For each animal, one of the two tendons was taken at random and exposed to a pressure of 300 MPa (n=9) or 600 MPa (n=10). The contralateral tendon served as an untreated control. The biomechanical properties of the tendons remained unchanged with respect to the tested parameters: Young's modulus (MPa) and tensile strength (MPa). This finding is in line with immunohistochemical labeling results, as no difference in the labeling pattern of collagen I and versican was observed when comparing the HHP group (at 600 MPa) to the untreated control group. We anticipate that during orthopedic surgery HHP can serve as a novel, promising methodical approach to inactivate Achilles tendon and bone cells without altering the biomechanical properties of the tendons. This should allow one to preserve the attachment of tendon and ligaments to the devitalized bone and to facilitate functional reconstruction. (author)

  9. Functional and magnetic resonance imaging evaluation after single-tendon rotator cuff reconstruction

    DEFF Research Database (Denmark)

    Knudsen, H B; Gelineck, J; Søjbjerg, Jens Ole

    1999-01-01

    The aim of this study was to investigate tendon integrity after surgical repair of single-tendon rotator cuff lesions. In 31 patients, 31 single-tendon repairs were evaluated. Thirty-one patients were available for clinical assessment and magnetic resonance imaging (MRI) at follow-up. A standard...... series of MR images was obtained for each. The results of functional assessment were scored according to the system of Constant. According to MRI evaluation, 21 (68%) patients had an intact or thinned rotator cuff and 10 (32%) had recurrence of a full-thickness cuff defect at follow-up. Patients...... with an intact or thinned rotator cuff had a median Constant score of 75.5 points; patients with a full-thickness cuff defect had a median score of 62 points. There was no correlation between tendon integrity on postoperative MR images and functional outcome. Patients with intact or thinned cuffs did not have...

  10. Intra-articular membranous interposition detected by MRI in developmental dysplasia of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, W.; Itoi, Eiji; Sato, Kozo [Akita Univ. (Japan). Dept. of Orthopedic Surgery

    2000-12-01

    Intra-articular membranous interposition was detected by MRI in the hip joint with residual subluxation of a girl aged 5 years 10 months. This structure, which had low signal intensity on both T1- and T2-weighted images, separated the femoral head from the acetabulum. Histological examination revealed chondrometaplasia, which suggested that this interposition might be transformed to a surface cartilaginous tissue of the secondary acetabulum often observed in residual subluxation of the hip. (orig.)

  11. Outcome of different facial nerve reconstruction techniques

    Directory of Open Access Journals (Sweden)

    Aboshanif Mohamed

    Full Text Available Abstract Introduction: There is no technique of facial nerve reconstruction that guarantees facial function recovery up to grade III. Objective: To evaluate the efficacy and safety of different facial nerve reconstruction techniques. Methods: Facial nerve reconstruction was performed in 22 patients (facial nerve interpositional graft in 11 patients and hypoglossal-facial nerve transfer in another 11 patients. All patients had facial function House-Brackmann (HB grade VI, either caused by trauma or after resection of a tumor. All patients were submitted to a primary nerve reconstruction except 7 patients, where late reconstruction was performed two weeks to four months after the initial surgery. The follow-up period was at least two years. Results: For facial nerve interpositional graft technique, we achieved facial function HB grade III in eight patients and grade IV in three patients. Synkinesis was found in eight patients, and facial contracture with synkinesis was found in two patients. In regards to hypoglossal-facial nerve transfer using different modifications, we achieved facial function HB grade III in nine patients and grade IV in two patients. Facial contracture, synkinesis and tongue atrophy were found in three patients, and synkinesis was found in five patients. However, those who had primary direct facial-hypoglossal end-to-side anastomosis showed the best result without any neurological deficit. Conclusion: Among various reanimation techniques, when indicated, direct end-to-side facial-hypoglossal anastomosis through epineural suturing is the most effective technique with excellent outcomes for facial reanimation and preservation of tongue movement, particularly when performed as a primary technique.

  12. 21 CFR 872.3970 - Interarticular disc prosthesis (interpositional implant).

    Science.gov (United States)

    2010-04-01

    ... implant). 872.3970 Section 872.3970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3970 Interarticular disc prosthesis (interpositional implant). (a) Identification. An interarticular disc prosthesis...

  13. Does Donor Age of Nonirradiated Achilles Tendon Allograft Influence Mid-Term Results of Revision ACL Reconstruction?

    Science.gov (United States)

    Zaffagnini, Stefano; Roberti di Sarsina, Tommaso; Bonanzinga, Tommaso; Nitri, Marco; Macchiarola, Luca; Stefanelli, Federico; Lucidi, Gianandrea; Grassi, Alberto

    2018-01-01

    Purpose  The purpose of the present study was to investigate if the donor age of nonirradiated Achilles tendon allograft could influence the clinical results of revision anterior cruciate ligament (ACL) reconstruction. Methods  All patients that underwent ACL revision between 2004 and 2008 with at least 4 years of follow-up were included. For all the patients that met the inclusion criteria, the age of the graft donor was obtained from the tissue bank. Lysholm score was administered to patients that met inclusion criteria. In addition, patients were divided in two groups based on the donor age (<45 years vs. ≥45 years), and the baseline characteristics and outcomes were compared. Results  Fifty-two patients were evaluated at a mean 4.8 ± 0.8 years follow-up with Lysholm score. The Lysholm significantly improved from 62.3 ± 6.6 at preoperative status to 84.4 ± 12.3 at final follow-up. The mean donor age was 48.7 ± 8.4 years; a significant difference in Lysholm score was noted between patients that received an allograft with a donor age <45 years (14 patients; 27%) and those receiving an allograft with a donor age ≥45 years (38; 73%) (89.5 ± 3.2 vs. 80.1 ± 11.1, respectively; p  = 0.0469). The multiple regression model showed the donor age, the final follow-up, and the preoperative Lysholm score as significant predictors of postoperative Lysholm score ( p  < 0.0002). Conclusion  Donor age of nonirradiated Achilles tendon allograft influenced the mid-term results of revision ACL reconstruction, thus advising the use of grafts from young donors. Level of Evidence  Level III, retrospective comparative study. PMID:29675501

  14. Interpositional Gap Arthroplasty by Versatile Pedicled Temporalis Myofascial Flap in the Management of Temporomandibular Joint Ankylosis- A Case Series Study.

    Science.gov (United States)

    Aneja, Vikas; Raval, Rushik; Bansal, Anupam; Kumawat, Vinod; Kaur, Jasleen; Shaikh, Ahemer Arif

    2016-10-01

    Temporomandibular Joint (TMJ) ankylosis is a situation in which the mandibular condyle is fused to the glenoid fossa by bone or fibrous tissue. The management of TMJ ankylosis has a complicated chore and it is challenging for the maxillofacial surgeon because of technical hitches and high rate of re-ankylosis. Interpositional gap arthroplasty is one of the modalities for its management. A range of inter-positional materials have been used to avert recurrence after gap arthroplasty in TMJ ankylosis. The aim of this series was to evaluate the effectiveness of the temporomyofacial flap in the treatment of TMJ ankylosis as an interpositional gap arthroplasty. A total of 10 cases with unilateral TMJ ankylosis were treated by interpositional gap arthroplasty by pedicled temporalis myofacial flap and evaluated with a follow-up of 6 months to 5 years (Mean 3.3 years) for the functional stability of TMJ. All the patients were successfully treated. There were no signs of recurrence in any patients up to last follow up visit. The result showed that temporalis myofascial flap is a preferable choice for inter-positional gap arthroplasty which proves its versatility as an inter-positional material.

  15. Outcome of different facial nerve reconstruction techniques.

    Science.gov (United States)

    Mohamed, Aboshanif; Omi, Eigo; Honda, Kohei; Suzuki, Shinsuke; Ishikawa, Kazuo

    There is no technique of facial nerve reconstruction that guarantees facial function recovery up to grade III. To evaluate the efficacy and safety of different facial nerve reconstruction techniques. Facial nerve reconstruction was performed in 22 patients (facial nerve interpositional graft in 11 patients and hypoglossal-facial nerve transfer in another 11 patients). All patients had facial function House-Brackmann (HB) grade VI, either caused by trauma or after resection of a tumor. All patients were submitted to a primary nerve reconstruction except 7 patients, where late reconstruction was performed two weeks to four months after the initial surgery. The follow-up period was at least two years. For facial nerve interpositional graft technique, we achieved facial function HB grade III in eight patients and grade IV in three patients. Synkinesis was found in eight patients, and facial contracture with synkinesis was found in two patients. In regards to hypoglossal-facial nerve transfer using different modifications, we achieved facial function HB grade III in nine patients and grade IV in two patients. Facial contracture, synkinesis and tongue atrophy were found in three patients, and synkinesis was found in five patients. However, those who had primary direct facial-hypoglossal end-to-side anastomosis showed the best result without any neurological deficit. Among various reanimation techniques, when indicated, direct end-to-side facial-hypoglossal anastomosis through epineural suturing is the most effective technique with excellent outcomes for facial reanimation and preservation of tongue movement, particularly when performed as a primary technique. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  16. Loss of reduction and complications of coracoclavicular ligament reconstruction with autogenous tendon graft in acute acromioclavicular dislocations.

    Science.gov (United States)

    Choi, Nam Hong; Lim, Seok Min; Lee, Sang Young; Lim, Tae Kang

    2017-04-01

    This study was conducted to report loss of reduction and complications after single-tunnel coracoclavicular (CC) ligament reconstruction with autogenous semitendinosus tendon graft for acute acromioclavicular (AC) joint dislocations. This retrospective study included patients with acute, unstable AC dislocations (surgery within 6 weeks after trauma). We excluded patients with chronic injury and distal clavicle fractures with CC ligaments disruption. We measured the CC distance on anteroposterior radiographs of both clavicles, preoperatively, immediately postoperatively, and at the final follow-up visit. We evaluated clinical outcomes using the American Shoulder and Elbow Surgeons Shoulder Assessment and the University of California, Los Angeles Shoulder Rating Scale scores and perioperative complications. There were 30 patients (27 men and 3 women) with mean age of 41 years (range, 19-70 years). The mean follow-up period was 31 months (range, 12-186 months). Mean CC distance was 15.5 ± 3.7 mm (84% ± 14% of the contralateral shoulder) preoperatively, 8.9 ± 2.6 mm (9% ± 40%) immediately postoperatively (P 25% increase of CC distance) developed in 14 patients (47%), and complications occurred in 6 patients (20%), including 3 distal clavicle fractures through the tunnel. Final clinical scores were significantly lower in patients with complications (27 vs. 33 of the University of California, Los Angeles assessment [P < .001] and 81 vs. 95 of the American Shoulder and Elbow Surgeons Shoulder assessment [P < .001]). In acute AC joint dislocation, single-tunnel CC ligament reconstruction using autogenous tendon graft resulted in loss of reduction rate of 47% and a complication rate of 20%. The development of complications adversely affected clinical outcomes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  17. Mechanical properties of human bone-tendon-bone grafts preserved by different methods and radiation sterilised

    International Nuclear Information System (INIS)

    Kaminski, A.; Gut, G.

    2008-01-01

    Full text: Patellar tendon auto and allografts are commonly used in orthopaedic surgery for reconstruction of the anterior crucial ligaments (ACL). Autografts are mainly used for primary reconstruction, while allografts are useful for revision surgery. To avoid the risk of infection diseases transmission allografts should be radiation-sterilised. As radiation-sterilisation is supposed to decrease the mechanical strength of tendon tissue, it is important to establish methods of allografts preservation and sterilisation resulting in their best quality and safety. Therefore, the purpose of the study was to compare the tensile strength of the central one third of human patellar tendon (as used for ACL reconstruction), preserved by different methods (deep fresh freezing, lyophilisation) and subsequently radiation-sterilised with doses of 0 (control), 25, 50 or 100 kGy. Bone-tendon-bone grafts were prepared from cadaveric human patella tendon with both patellar and tibial attachments. BTB grafts were preserved by deep freezing, glicerolisation or lyophilisation and radiation-sterilised with doses of 0 (control), 25, 50 or 100 kGy. To estimate mechanical properties all samples were subjected to tensile tests to failure using Instron system. Before these tests all lyophilised grafts were rehydrated. We found decrease of tensile strength of irradiated grafts compared to non-irradiated controls. Obtained results of the mechanical testing of studied grafts indicate their potential usefulness for clinical applications.(Author)

  18. Rupture Following Biceps-to-Triceps Tendon Transfer in Adolescents and Young Adults With Spinal Cord Injury:

    Science.gov (United States)

    Merenda, Lisa A.; Rutter, Laure; Curran, Kimberly; Kozin, Scott H.

    2012-01-01

    Background: Tendon transfer surgery can restore elbow extension in approximately 70% of persons with tetraplegia and often results in antigravity elbow extension strength. However, we have noted an almost 15% rupture/attenuation rate. Objective: This investigation was conducted to analyze potential causes in adolescents/young adults with spinal cord injury (SCI) who experienced tendon rupture or attenuation after biceps-to-triceps transfer. Methods: Medical charts of young adults with SCI who underwent biceps-to-triceps transfer and experienced tendon rupture or attenuation were reviewed. Data collected by retrospective chart review included general demographics, surgical procedure(s), use and duration of antibiotic treatment, time from tendon transfer surgery to rupture/attenuation, and method of diagnosis. Results: Twelve subjects with tetraplegia (mean age, 19 years) who underwent biceps-to-triceps reconstruction with subsequent tendon rupture or attenuation were evaluated. Mean age at time of tendon transfer was 18 years (range, 14-21 years). A fluoroquinolone was prescribed for 42% (n=5) of subjects. Tendon rupture was noted in 67% (n=8), and attenuation was noted in 33% (n=4). Average length of time from surgery to tendon rupture/attenuation was 5.7 months (range, 3-10 months). Conclusion: Potential contributing causes of tendon rupture/attenuation after transfer include surgical technique, rehabilitation, co-contraction of the transfer, poor patient compliance, and medications. In this cohort, 5 subjects were prescribed fluoroquinolones that have a US Food and Drug Administration black box concerning tendon ruptures. Currently, all candidates for upper extremity tendon transfer reconstruction are counseled on the effects of fluoroquinolones and the potential risk for tendon rupture. PMID:23459326

  19. Specialisation of extracellular matrix for function in tendons and ligaments

    Science.gov (United States)

    Birch, Helen L.; Thorpe, Chavaunne T.; Rumian, Adam P.

    2013-01-01

    Summary Tendons and ligaments are similar structures in terms of their composition, organisation and mechanical properties. The distinction between them stems from their anatomical location; tendons form a link between muscle and bone while ligaments link bones to bones. A range of overlapping functions can be assigned to tendon and ligaments and each structure has specific mechanical properties which appear to be suited for particular in vivo function. The extracellular matrix in tendon and ligament varies in accordance with function, providing appropriate mechanical properties. The most useful framework in which to consider extracellular matrix differences therefore is that of function rather than anatomical location. In this review we discuss what is known about the relationship between functional requirements, structural properties from molecular to gross level, cellular gene expression and matrix turnover. The relevance of this information is considered by reviewing clinical aspects of tendon and ligament repair and reconstructive procedures. PMID:23885341

  20. Repeated freeze-thaw cycles reduce the survival rate of osteocytes in bone-tendon constructs without affecting the mechanical properties of tendons.

    Science.gov (United States)

    Suto, Kaori; Urabe, Ken; Naruse, Kouji; Uchida, Kentaro; Matsuura, Terumasa; Mikuni-Takagaki, Yuko; Suto, Mitsutoshi; Nemoto, Noriko; Kamiya, Kentaro; Itoman, Moritoshi

    2012-03-01

    Frozen bone-patellar tendon bone allografts are useful in anterior cruciate ligament reconstruction as the freezing procedure kills tissue cells, thereby reducing immunogenicity of the grafts. However, a small portion of cells in human femoral heads treated by standard bone-bank freezing procedures survive, thus limiting the effectiveness of allografts. Here, we characterized the survival rates and mechanisms of cells isolated from rat bones and tendons that were subjected to freeze-thaw treatments, and evaluated the influence of these treatments on the mechanical properties of tendons. After a single freeze-thaw cycle, most cells isolated from frozen bone appeared morphologically as osteocytes and expressed both osteoblast- and osteocyte-related genes. Transmission electron microscopic observation of frozen cells using freeze-substitution revealed that a small number of osteocytes maintained large nuclei with intact double membranes, indicating that these osteocytes in bone matrix were resistant to ice crystal formation. We found that tendon cells were completely killed by a single freeze-thaw cycle, whereas bone cells exhibited a relatively high survival rate, although survival was significantly reduced after three freeze-thaw cycles. In patella tendons, the ultimate stress, Young's modulus, and strain at failure showed no significant differences between untreated tendons and those subjected to five freeze-thaw cycles. In conclusion, we identified that cells surviving after freeze-thaw treatment of rat bones were predominantly osteocytes. We propose that repeated freeze-thaw cycles could be applied for processing bone-tendon constructs prior to grafting as the treatment did not affect the mechanical property of tendons and drastically reduced surviving osteocytes, thereby potentially decreasing allograft immunogenecity.

  1. A novel technique for distal fingertip replantation: Polypropylene suture guided interpositional vein graft.

    Science.gov (United States)

    Dadaci, Mehmet; Ince, Bilsev; Altuntas, Zeynep; Bitik, Ozan; Uzun, Hakan; Bilgen, Fatma

    2015-05-04

    Despite current advances in microsurgery, fingertip replantation is still controversial, mainly due to its difficulty and cost. The purpose of this study is to describe a new technique of interposition vein graft guided by polypropylene suture in distal fingertip replantation. A total of eight consecutive Tamai zone 1 fingertip replantations performed by the same author were included. All replantations were performed using interposition vein graft guided by polypropylene suture. This technique involved a vein graft of ∼ 2 cm, with appropriate calibration, obtained from the volar part of the forearm and a 2-0 polyprolene suture passed through the interposition vein graft. Then, a polypropylene suture guide carrying the vein graft was inserted into the artery. The anastomosis was easily performed with the aid of 10-0 or 11-0 nylon in a bloodless medium and without encountering the posterior wall problem. Average surgery time was 2.5 hours (range = 2-3 hours). Among eight Tamai zone 1 replantations, six were successful (75%). There were two replantations lost because of arterial failure. This technique may ease fingertip replantations and increase the success rate for Tamai zone 1 injuries.

  2. Influence of an interpositional spacer on the behaviour of the tibiofemoral joint: a finite element study.

    Science.gov (United States)

    Checa, S; Taylor, M; New, A

    2008-10-01

    Interpositional arthroplasty is considered by many surgeons for the treatment of isolated medial compartment osteoarthritis of the knee. In this procedure, an interpositional spacer is inserted into the medial compartment of the joint with no bone resection and no mechanical fixation. Major problems such as implant dislocation, severe pain or need for revision have been reported post-operatively. In this study, the kinematics of a knee implanted with an interpositional spacer made of either polyurethane or cobalt-chrome during walking, stair ascent and squatting cycles have been predicted and compared to the normal knee using finite element analysis. In addition, articular cartilage stress histories have been examined to obtain distributions of cumulative stress, a measure of the likelihood of articular cartilage degeneration. The insertion of a polyurethane interpositional spacer in the medial side of the knee did not affect knee kinematics as compared to the normal knee, but caused an increase of articular cartilage cumulative contact stress exposures in the medial compartment of the joint. The knee implanted with the Co-Cr spacer exhibited similar trends in knee kinematics, however significantly different ranges of motion were observed during some periods of the activity cycles, specifically during the first half of the walking cycle where lower ranges of motion were predicted. In addition, higher articular cartilage cumulative contact stress exposures were observed in both compartments of the knee. In both cases, cumulative contact stress exposures of the tibial articular cartilage were more affected than those of the femoral articular cartilage. These results suggest implant material as an important parameter in the design phase of interpositional spacers.

  3. Tendon surveillance requirements - average tendon force

    International Nuclear Information System (INIS)

    Fulton, J.F.

    1982-01-01

    Proposed Rev. 3 to USNRC Reg. Guide 1.35 discusses the need for comparing, for individual tendons, the measured and predicted lift-off forces. Such a comparison is intended to detect any abnormal tendon force loss which might occur. Recognizing that there are uncertainties in the prediction of tendon losses, proposed Guide 1.35.1 has allowed specific tolerances on the fundamental losses. Thus, the lift-off force acceptance criteria for individual tendons appearing in Reg. Guide 1.35, Proposed Rev. 3, is stated relative to a lower bound predicted tendon force, which is obtained using the 'plus' tolerances on the fundamental losses. There is an additional acceptance criterion for the lift-off forces which is not specifically addressed in these two Reg. Guides; however, it is included in a proposed Subsection IWX to ASME Code Section XI. This criterion is based on the overriding requirement that the magnitude of prestress in the containment structure be sufficeint to meet the minimum prestress design requirements. This design requirement can be expressed as an average tendon force for each group of vertical hoop, or dome tendons. For the purpose of comparing the actual tendon forces with the required average tendon force, the lift-off forces measured for a sample of tendons within each group can be averaged to construct the average force for the entire group. However, the individual lift-off forces must be 'corrected' (normalized) prior to obtaining the sample average. This paper derives the correction factor to be used for this purpose. (orig./RW)

  4. Patellar Sleeve Fracture With Ossification of the Patellar Tendon.

    Science.gov (United States)

    Damrow, Derek S; Van Valin, Scott E

    2017-03-01

    Patellar sleeve fractures make up greater than 50% of all patellar fractures. They are essentially only seen in the pediatric population because of the thick periosteum and the distal patellar pole apophysis in this group. These fractures can lead to complications if not treated appropriately and in a timely fashion. Complications of missed or untreated patellar sleeve fractures include patella alta, anterior knee pain, and quadriceps atrophy. These can all result in severe limitations in activity. The authors describe a case of a 16-year-old boy who sustained a patellar sleeve fracture 3 years prior to presentation. On presentation, he had patella alta, diminished strength, 5° of extensor lag, and radiographs that revealed bone formation along the patellar tendon. Despite this, he was able to maintain a high level of activity. This case report explores how the patient could have maintained a high level of activity despite having a patellar sleeve fracture. Also, because of the delayed presentation, the patella was ossified and the quadriceps was retracted, which led to a novel approach to reconstructing his distal extensor mechanism. This approach included a V-Y advancement of the quadriceps tendon and patellar tendon reconstruction using the patient's hamstring tendon (semitendinosus). This technique, combined with physical therapy postoperatively, resulted in his return to varsity high school soccer. To the best of the authors' knowledge, this technique has not been reported for this rare condition. [Orthopedics. 2017; 40(2):e357-e359.]. Copyright 2016, SLACK Incorporated.

  5. Effect of repeated freezing-thawing on the Achilles tendon of rabbits.

    Science.gov (United States)

    Chen, Lianxu; Wu, Yanping; Yu, Jiakuo; Jiao, Zhaode; Ao, Yingfang; Yu, Changlong; Wang, Jianquan; Cui, Guoqing

    2011-06-01

    The increased use of allograft tissue in the reconstruction of anterior cruciate ligament has brought more focus to the effect of storage and treatment on allograft. The purpose of this study was to observe the effect of histology and biomechanics on Achilles tendon in rabbits through repeated freezing-thawing before allograft tendon transplantation. Rabbit Achilles tendons were harvested and processed according to the manufacture's protocol of tissue bank, and freezing-thawing was repeated three times (group 1) and ten times (group 2). Those received only one cycle were used as controls. Then, tendons in each group were selected randomly to make for histological observations and biomechanics test. Histological observation showed that the following changes happened as the number of freezing-thawing increased: the arrangement of tendon bundles and collagen fibrils became disordered until ruptured, cells disrupted and apparent gaps appeared between tendon bundle because the formation of ice crystals. There were significant differences between the experimental and control groups in the values of maximum load, energy of maximum load and maximum stress, whereas no significant differences existed in other values such as stiffness, maximum strain, elastic modulus, and energy density. Therefore, repeated freezing-thawing had histological and biomechanical effect on Achilles tendon in rabbits before allograft tendon transplantation. This indicates that cautions should be taken in the repeated freezing-thawing preparation of allograft tendons in clinical application.

  6. Interposition of the posterior cruciate ligament into the medial compartment of the knee joint on coronal magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Su; Yoon, Young Cheol; Park, Ki Jeong; Wang, Joon Ho [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Choe, Bong Keun [Dept. of Preventive Medicine, Kyung Hee University School of Medicine, Seoul (Korea, Republic of)

    2016-04-15

    The purpose of our study was to evaluate the overall prevalence and clinical significance of interposition of the posterior cruciate ligament (PCL) into the medial compartment of the knee joint in coronal magnetic resonance imaging (MRI). We retrospectively reviewed 317 consecutive patients referred for knee MRI at our institution between October 2009 and December 2009. Interposition of the PCL into the medial compartment of the knee joint on proton coronal MRI was evaluated dichotomously (i.e., present or absent). We analyzed the interposition according to its prevalence as well as its relationship with right-left sidedness, gender, age, and disease categories (osteoarthritis, anterior cruciate ligament tear, and medial meniscus tear). Prevalence of interposition of PCL into the medial compartment of the knee joint was 47.0% (149/317). There was no right (50.0%, 83/166) to left (43.7%, 66/151) or male (50.3%, 87/173) to female (43.1%, 62/144) differences in the prevalence. There was no significant association between the prevalence and age, or the disease categories. Interposition of the PCL into the medial compartment of the knee joint is observed in almost half of patients on proton coronal MRI of the knee. Its presence is not associated with any particular factors including knee pathology and may be regarded as a normal MR finding.

  7. A Case Report of Ridge Augmentation using Onlay Interpositional Graft: An Approach to Improve Prosthetic Prognosis of a Deficit Ridge

    Directory of Open Access Journals (Sweden)

    Devanand Shetty

    2014-01-01

    Full Text Available Background: Periodontal therapy has developed beyond the scope of the treatment of periodontal pathoses. Periodontal plastic surgery consists of the reconstructive procedures designed to enhance the both function and esthetics. Deficient ridges pose a severe problem to the restorative dentist in restoring the natural form, function and esthetics of the prosthesis replacing the natural dentition. Depending upon the severity, location of these defects and the prosthetic option chosen, hard and soft tissue ridge augmentation or non-surgical approach or a combination may help to address them. The present clinical report describes a soft tissue ridge augmentation of a localized ridge defect in maxillary aesthetic region using onlay interpositional graft followed by fixed partial denture.

  8. Functional reconstruction of ischemic contracture in the

    Directory of Open Access Journals (Sweden)

    TANG Hao

    2011-04-01

    Full Text Available 【Abstract】Objective: To discuss the method of functional reconstruction of ischemic contracture in the lower limb and propose a classification protocol for ischemic contracture in the lower limb based on its severity and prognosis. Methods: A total of 42 patients with ischemic contracture in the lower limb were included in this study. According to different types of disturbance and degrees of severity, surgical reconstructions consisting of nerve decompression, tendon lengthening or transfer, intrinsic foot muscle release and sural-tibial nerve anastomosis were performed in every patient. Results: Postoperatively, all patients were able to walk on flat ground. Drop foot was corrected in 10 patients, and 5 patients still felt some difficulty during stair activity. Split Achilles tendon transfer to flexor hallucis longus tendon was performed in 12 patients, and their walking stability was improved. Seven patients accepted ipsilateral suraltibial nerve anastomosis, and sensitivity recovery reached to S2 in 2 patients and S3 in 5 patients. Conclusions: Ischemic contracture in the lower limb is a devastating complication after lower limb trauma. The prevention of contracture is much more important than the treatment of an established contracture. Split Achilles tendon transfer to flexor hallucis longus tendon and sural-tibial nerve anastomosis, which was initially implemented by us, could improve the functional recovery of ischemic contracture in lower limbs, and thus provides a new alternative for functional reconstruction of ischemic contracture in the lower limb. Key words: Ischemic contracture; Classification; Recovery of function

  9. Iliopsoas Tendon Reformation after Psoas Tendon Release

    Directory of Open Access Journals (Sweden)

    K. Garala

    2013-01-01

    Full Text Available Internal snapping hip syndrome, or psoas tendonitis, is a recognised cause of nonarthritic hip pain. The majority of patients are treated conservatively; however, occasionally patients require surgical intervention. The two surgical options for iliopsoas tendinopathy are step lengthening of the iliopsoas tendon or releasing the tendon at the lesser trochanter. Although unusual, refractory snapping usually occurs soon after tenotomy. We report a case of a 47-year-old active female with internal snapping and pain following an open psoas tenotomy. Postoperatively she was symptom free for 13 years. An MRI arthrogram revealed reformation of a pseudo iliopsoas tendon reinserting into the lesser trochanter. The pain and snapping resolved after repeat iliopsoas tendon release. Reformation of tendons is an uncommon sequela of tenotomies. However the lack of long-term studies makes it difficult to calculate prevalence rates. Tendon reformation should be included in the differential diagnosis of failed tenotomy procedures after a period of symptom relief.

  10. Extensor Tendon Instability Due to Sagittal Band Injury in a Martial Arts Athlete: A Case Report.

    Science.gov (United States)

    Kochevar, Andrew; Rayan, Ghazi

    2017-03-01

    A Taekwondo participant sustained a hand injury from punching an opponent that resulted in painful instability of the ring finger extensor digitorum communis tendon due to sagittal band damage. His symptoms resolved after reconstructive surgery on the sagittal band (SB) with stabilization of the extensor tendon over the metacarpophalangeal joint.

  11. The prevalence of tenosynovitis of the interosseous tendons of the hand in patients with rheumatoid arthritis.

    OpenAIRE

    Rowbotham, EL; Freeston, JE; Emery, P; Grainger, AJ

    2015-01-01

    AIM: The aim of this study was to establish the prevalence of tenosynovitis affecting the interosseous tendons of the hand in a rheumatoid arthritis (RA) population and to assess for association with metacarpophalangeal (MCP) joint synovitis, flexor tendon tenosynovitis or ulnar drift. METHODS: Forty-four patients with RA underwent hand MRI along with 20 normal controls. Coronal 3D T1 VIBE sequences pre- and post-contrast were performed and reconstructed. The presence of interosseous tendon t...

  12. Peroneal perforator-based peroneus longus tendon and sural neurofasciocutaneous composite flap transfer for a large soft-tissue defect of the forearm: A case report.

    Science.gov (United States)

    Hayashida, Kenji; Saijo, Hiroto; Fujioka, Masaki

    2018-01-01

    We describe the use of a composite flap composed of a sural neurofasciocutaneous flap and a vascularized peroneus longus tendon for the reconstruction of severe composite forearm tissue defects in a patient. A 43-year-old man had his left arm caught in a conveyor belt resulting in a large soft-tissue defect of 18 × 11 cm over the dorsum forearm. The extensor carpi radialis, superficial radial nerve, and radial artery were severely damaged. A free neurofasciocutaneous composite flap measuring 16 × 11 cm was outlined on the patient's left lower leg to allow simultaneous skin, tendon, nerve, and artery reconstruction. The flap, which included the peroneus longus tendon, was elevated on the subfascial plane. After the flap was transferred to the recipient site, the peroneal artery was anastomosed to the radial artery in a flow-through manner. The vascularized tendon graft with 15 cm in length was used to reconstruct the extensor carpi radialis longus tendon defect using an interlacing suture technique. As the skin paddle of the sural neurofasciocutaneous flap and the vascularized peroneus longus tendon graft were linked by the perforator and minimal fascial tissue, the skin paddle was able to rotate and slide with comparative ease. The flap survived completely without any complications. The length of follow-up was 12 months and was uneventful. Range of motion of his left wrist joint was slightly limited to 75 degrees. This novel composite flap may be useful for reconstructing long tendon defects associated with extensive forearm soft tissue defects. © 2016 Wiley Periodicals, Inc.

  13. Orthotopic Transplantation of Achilles Tendon Allograft in Rats

    Science.gov (United States)

    Aynardi, Michael; Zahoor, Talal; Mitchell, Reed; Loube, Jeffrey; Feltham, Tyler; Manandhar, Lumanti; Paudel, Sharada; Schon, Lew; Zhang, Zijun

    2018-01-01

    The biology and function of orthotopic transplantation of Achilles tendon allograft are unknown. Particularly, the revitalization of Achilles allograft is a clinical concern. Achilles allografts were harvested from donor rats and stored at −80 °C. Subcutaneous adipose tissue was harvested from the would-be allograft recipient rats for isolation of mesenchymal stem cells (MSCs). MSCs were cultured with growth differentiation factor-5 (GDF-5) and applied onto Achilles allografts on the day of transplantation. After the native Achilles tendon was resected from the left hind limb of the rats, Achilles allograft, with or without autologous MSCs, was implanted and sutured with calf muscles proximally and calcaneus distally. Animal gait was recorded presurgery and postsurgery weekly. The animals were sacrificed at week 4, and the transplanted Achilles allografts were collected for biomechanical testing and histology. The operated limbs had altered gait. By week 4, the paw print intensity, stance time, and duty cycle (percentage of the stance phase in a step cycle) of the reconstructed limbs were mostly recovered to the baselines recorded before surgery. Maximum load of failure was not different between Achilles allografts, with or without MSCs, and the native tendons. The Achilles allograft supplemented with MSCs had higher cellularity than the Achilles allograft without MSCs. Deposition of fine collagen (type III) fibers was active in Achilles allograft, with or without MSCs, but it was more evenly distributed in the allografts that were incubated with MSCs. In conclusion, orthotopically transplanted Achilles allograft healed with host tissues, regained strength, and largely restored Achilles function in 4 wk in rats. It is therefore a viable option for the reconstruction of a large Achilles tendon defect. Supplementation of MSCs improved repopulation of Achilles allograft, but large animal models, with long-term follow up and cell tracking, may be required to fully

  14. The effect of ileal interposition surgery on enteroendocrine cell numbers in the UC Davis type 2 diabetes mellitus rat

    DEFF Research Database (Denmark)

    Hansen, Carl Frederik; Vassiliadis, Efstathios; Vrang, Niels

    2014-01-01

    To investigate the short-term effect of ileal interposition (IT) surgery on gut morphology and enteroendocrine cell numbers in the pre-diabetic UC Davis type 2 diabetes mellitus (UCD-T2DM) rat.......To investigate the short-term effect of ileal interposition (IT) surgery on gut morphology and enteroendocrine cell numbers in the pre-diabetic UC Davis type 2 diabetes mellitus (UCD-T2DM) rat....

  15. Robotic-assisted vesicovaginal fistula repair using an extravesical approach without interposition grafting.

    Science.gov (United States)

    Kelly, Erin; Wu, Maria Y; MacMillan, J Barry

    2018-03-01

    Post-hysterectomy vesicovaginal fistula (VVF) is rare. In addition to conventional abdominal and vaginal approaches, robotic-assisted VVF repairs have recently been described. We present a case of an extravesical, robotic-assisted VVF repair, without placement of an interposition graft performed in a Canadian teaching center. A 51-year-old woman presented with urinary incontinence 5 days after laparoscopic hysterectomy. Computed tomography cystogram, cystoscopy, and methylene blue dye test, confirmed a VVF above the bladder trigone. The patient underwent a robotic-assisted VVF repair 3 months after presentation, without complication. An abdominal, extravesical approach was used. Operative time was 116 min and repeat CT cystogram showed no evidence of persistent. We have demonstrated that a VVF repair, using a robotic-assisted, extravesical approach without interposition graft placement, can be safe, less invasive and have a successful outcome at 1 year of follow-up.

  16. In vivo engineering of a functional tendon sheath in a hen model.

    Science.gov (United States)

    Xu, Liang; Cao, Dejun; Liu, Wei; Zhou, Guangdong; Zhang, Wen Jie; Cao, Yilin

    2010-05-01

    Repair of injured tendon sheath remains a major challenge and this study explored the possibility of in vivo reconstruction of a tendon sheath with tendon sheath derived cells and polyglycolic acid (PGA) fibers in a Leghorn hen model. Total 55 Leghorn hens with a 1cm tendon sheath defect created in the left middle toe of each animal were randomly assigned into: (1) experimental group (n=19) that received a cell-PGA construct; (2) scaffold control group (n=18) that received a cell-free PGA scaffold; (3) blank control group (n=18) with the defect untreated. Tendon sheath cells were isolated, in vitro expanded, and seeded onto PGA scaffolds. After in vitro culture for 7 days, the constructs were in vivo implanted to repair the sheath defects. Alcian blue staining confirmed the ability of cultured cells to produce specific matrices containing acidic carboxyl mucopolysaccharide (mainly hyaluronic acid). In addition, the engineered sheath formed a relatively mature structure at 12 weeks post-surgery, which was similar to that of native counterpart, including a smooth inner surface, a well-developed sheath histological structure with a clear space between the tendon and the engineered sheath. More importantly, Work of Flexion assay revealed that the tendons needed less power consumption to glide inside the engineered sheath when compared to the tendons which were surrounded by scar-repaired tissues, indicating that the engineered sheaths had gained the function to a certain extent of preventing tendon adhesion. Taken together, these results suggest that tendon sheaths that are functionally and structurally similar to native sheaths are possible to be engineered in vivo using tendon sheath cells and PGA scaffolds. Copyright 2010 Elsevier Ltd. All rights reserved.

  17. The prevalence of tenosynovitis of the interosseous tendons of the hand in patients with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Rowbotham, Emma L.; Freeston, Jane E.; Emery, Paul; Grainger, Andrew J.

    2016-01-01

    The aim of this study was to establish the prevalence of tenosynovitis affecting the interosseous tendons of the hand in a rheumatoid arthritis (RA) population and to assess for association with metacarpophalangeal (MCP) joint synovitis, flexor tendon tenosynovitis or ulnar drift. Forty-four patients with RA underwent hand MRI along with 20 normal controls. Coronal 3D T1 VIBE sequences pre- and post-contrast were performed and reconstructed. The presence of interosseous tendon tenosynovitis was recorded alongside MCP joint synovitis, flexor tendon tenosynovitis and ulnar drift. Twenty-one (47.7 %) patients with RA showed interosseous tendon tenosynovitis. Fifty-two (14.8 %) interosseous tendons showed tenosynovitis amongst the RA patients. Interosseous tendon tenosynovitis was more commonly seen in association with adjacent MCP joint synovitis (p < 0.001), but nine MCP joints (5.1 %) showed adjacent interosseous tenosynovitis in the absence of joint synovitis. Interosseous tendon tenosynovitis was more frequently seen in fingers which also showed flexor tendon tenosynovitis (p < 0.001) and in patients with ulnar drift of the fingers (p = 0.01). Tenosynovitis of the hand interosseous tendons was found in 47.7 % of patients with RA. In the majority of cases this was adjacent to MCP joint synovitis; however, interosseous tendon tenosynovitis was also seen in isolation. (orig.)

  18. The prevalence of tenosynovitis of the interosseous tendons of the hand in patients with rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Rowbotham, Emma L. [Leeds Teaching Hospitals NHS Trust, Musculoskeletal Radiology Department, Leeds (United Kingdom); Freeston, Jane E. [Department of Rheumatology, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Emery, Paul [University of Leeds, Arthritis Research UK, Leeds Musculoskeletal Biomedical Research Unit, LTHT Leeds Institute of Rheumatic Musculoskeletal Medicine, Leeds (United Kingdom); Grainger, Andrew J. [Leeds Teaching Hospitals NHS Trust, Musculoskeletal Radiology Department, Leeds (United Kingdom); Chapel Allerton Hospital, NIHR Leeds Musculoskeletal Biomedical Research Unit, Leeds (United Kingdom)

    2016-02-15

    The aim of this study was to establish the prevalence of tenosynovitis affecting the interosseous tendons of the hand in a rheumatoid arthritis (RA) population and to assess for association with metacarpophalangeal (MCP) joint synovitis, flexor tendon tenosynovitis or ulnar drift. Forty-four patients with RA underwent hand MRI along with 20 normal controls. Coronal 3D T1 VIBE sequences pre- and post-contrast were performed and reconstructed. The presence of interosseous tendon tenosynovitis was recorded alongside MCP joint synovitis, flexor tendon tenosynovitis and ulnar drift. Twenty-one (47.7 %) patients with RA showed interosseous tendon tenosynovitis. Fifty-two (14.8 %) interosseous tendons showed tenosynovitis amongst the RA patients. Interosseous tendon tenosynovitis was more commonly seen in association with adjacent MCP joint synovitis (p < 0.001), but nine MCP joints (5.1 %) showed adjacent interosseous tenosynovitis in the absence of joint synovitis. Interosseous tendon tenosynovitis was more frequently seen in fingers which also showed flexor tendon tenosynovitis (p < 0.001) and in patients with ulnar drift of the fingers (p = 0.01). Tenosynovitis of the hand interosseous tendons was found in 47.7 % of patients with RA. In the majority of cases this was adjacent to MCP joint synovitis; however, interosseous tendon tenosynovitis was also seen in isolation. (orig.)

  19. A retrospective review of bone tunnel enlargement after anterior cruciate ligament reconstruction with hamstring tendons fixed with a metal round cannulated interference screw in the femur.

    Science.gov (United States)

    Kobayashi, Masahiko; Nakagawa, Yasuaki; Suzuki, Takashi; Okudaira, Shuzo; Nakamura, Takashi

    2006-10-01

    To assess bone tunnel enlargement after anterior cruciate ligament (ACL) reconstruction with the use of hamstring tendons fixed with a round cannulated interference (RCI) screw in the femur. A consecutive series of 30 ACL reconstructions performed with hamstring tendons fixed with an RCI screw in the femur and with staples via Leeds-Keio ligament in the tibia was retrospectively reviewed. The clinical outcome was evaluated through the Lysholm score. Anterior instability was tested by Telos-SE (Telos Japan, Tokyo, Japan) measurement. The location and angle of each femoral and tibial tunnel were measured with the use of plain radiographs, and bone tunnel enlargement greater than 2 mm detected any time 3, 6, 12, and 24 months postoperatively was defined as positive. Each factor (location and angle of the tunnels, sex, affected side, age, Lysholm score, and Telos-SE measurement) was compared between enlarged and nonenlarged groups. Positive enlargement of the bone tunnel (>2.0 mm) was observed in 36.7% (11 of 30) on the femoral side and 33.3% (10 of 30) on the tibial side, and in 6 knees of both sides. Half of patients (15 of 30) had an enlarged tunnel on the femoral or the tibial side until 1 year postoperatively. In most cases, enlargement reached maximum at 6 months postoperatively. Female patients tended to have an enlarged tunnel, especially on the femoral side (P < .05). Tunnel enlargement was not correlated with location and angle of the tunnels. Moreover, no difference was found in Lysholm score and Telos-SE measurement between enlarged and nonenlarged groups, although the nonenlarged group tended to exhibit higher Lysholm score and lesser instability. Bone tunnel enlargement of the femoral or tibial side was observed in half of patients (6 in both sides, 5 only in the femur, and 4 only in the tibia) after ACL reconstruction was performed with a hamstring tendon fixed with an RCI screw. Female patients had a greater chance for enlargement of the femoral tunnel

  20. [Successive ruptures of patellar and Achilles tendons. Anabolic steroids in competitive sports].

    Science.gov (United States)

    Isenberg, J; Prokop, A; Skouras, E

    2008-01-01

    Derivatives of testosterone or of 19-nor-testosterone are used as anabolics for the purpose of improving performance although the effect of anabolics is known still to be under discussion. The use of anabolic steroids continues among competitive athletes despite increased controls and increasingly frequent dramatic incidents connected with them. Whereas metabolic dysfunction during anabolic use is well documented, ruptures of the large tendons are rarely reported. Within 18 months, a 29-year-old professional footballer needed surgery for rupture of the patellar tendon and of both Achilles tendons. Carefully directed questioning elicited confirmation that he had taken different anabolic steroids regularly for 3 years with the intention of improving his strength. After each operation anabolic steroids were taken again at a high dosage during early convalescence and training. Minimally invasive surgery and open suturing techniques led to complete union of the Achilles tendons in good time. Training and anabolic use (metenolon 300 mg per week) started early after suturing of the patellar tendon including bone tunnels culminated in histologically confirmed rerupture after 8 weeks. After a ligament reconstruction with a semitendinosus tendon graft with subsequent infection, the tendon and reserve traction apparatus were lost. Repeated warnings of impaired healing if anabolic use was continued had been given without success. In view of the high number of unrecorded cases in competitive and athletic sports, we can assume that the use of anabolic steroids is also of quantitative relevance in the operative treatment of tendon ruptures.

  1. Miscellaneous conditions of tendons, tendon sheaths, and ligaments.

    Science.gov (United States)

    Dyson, S J; Dik, K J

    1995-08-01

    The use of diagnostic ultrasonography has greatly enhances our ability to diagnose injuries of tendons and tendon sheaths that were previously either unrecognized or poorly understood. For may of these injuries, there is currently only a small amount of follow-up data. This article considers injuries of the deep digital flexor tendon and its accessory ligament, the carpal tunnel syndrome soft tissue swellings on the dorsal aspect of the carpus, intertubercular (bicipital) bursitis and bicipital tendinitis, injuries of the gastrocnemius tendon, common calcaneal tendinitis, rupture of peroneus (fibularis tertius) and ligaments injuries of the back.

  2. Liquifying PLDLLA Anchor Fixation in Achilles Reconstruction for Insertional Tendinopathy.

    Science.gov (United States)

    Boden, Stephanie A; Boden, Allison L; Mignemi, Danielle; Bariteau, Jason T

    2018-04-01

    Insertional Achilles tendinopathy (IAT) is a frequent cause of posterior heel pain and is often associated with Haglund's deformity. Surgical correction for refractory cases of IAT has been well studied; however, the method of tendon fixation to bone in these procedures remains controversial, and to date, no standard technique has been identified for tendon fixation in these surgeries. Often, after Haglund's resection, there is large exposed cancellous surface for Achilles reattachment, which may require unique fixation to optimize outcomes. Previous studies have consistently demonstrated improved patient outcomes after Achilles tendon reconstruction with early rehabilitation with protected weight bearing, evidencing the need for a strong and stable anchoring of the Achilles tendon that allows early weight bearing without tendon morbidity. In this report, we highlight the design, biomechanics, and surgical technique of Achilles tendon reconstruction with Haglund's deformity using a novel technique that utilizes ultrasonic energy to liquefy the suture anchor, allowing it to incorporate into surrounding bone. Biomechanical studies have demonstrated superior strength of the suture anchor utilizing this novel technique as compared with prior techniques. However, future research is needed to ensure that outcomes of this technique are favorable when compared with outcomes using traditional suture anchoring methods. Level V: Operative technique.

  3. Anatomic double-bundle anterior cruciate ligament reconstruction using hamstring tendons with minimally required initial tension.

    Science.gov (United States)

    Mae, Tatsuo; Shino, Konsei; Matsumoto, Norinao; Natsu-Ume, Takashi; Yoneda, Kenji; Yoshikawa, Hideki; Yoneda, Minoru

    2010-10-01

    Our purpose was to clarify the clinical outcomes at 2 years after anatomic double-bundle anterior cruciate ligament (ACL) reconstruction with 20 N of the initial tension, which was the minimally required initial tension to perform the reconstruction successfully according to our previous report about the pre-tension necessary to restore the laxity found in the opposite knee (7.3 N; range, 2.2 to 14 N). Of 64 patients who underwent anatomic double-bundle ACL reconstruction with autogenous semitendinosus tendon, 45 were periodically examined for 2 years. Two double-looped grafts were fixed with EndoButton CL devices (Smith & Nephew Endoscopy, Andover, MA) on the femoral side and Double Spike Plates (Smith & Nephew Endoscopy) on the tibial side, while a total of 20 N of initial tension (10 N to each graft) was applied at 20° of knee flexion. The International Knee Documentation Committee Knee Examination Form and Lysholm score were used for the subjective assessment, whereas range of motion and knee stability were evaluated as the objective assessment. Grafts were evaluated in 25 patients with second-look arthroscopy. According to the International Knee Documentation Committee subjective assessment, 62% of knees were graded as normal and 38% as nearly normal. The Lysholm score was 72 points in the preoperative period and improved to 99 points at 2 years' follow-up. A loss of knee extension of less than 3° was found in 2 patients. The pivot-shift test was evaluated as negative in all patients except for 5 as a glide. KT-2000 knee arthrometer side-to-side difference (MEDmetric, San Diego, CA) was 0.1 ± 0.9 mm at 2 years' follow-up. Of the subset of grafts evaluated by second-look arthroscopy, most were considered to have good synovial coverage and to be taut. The anatomic double-bundle ACL reconstruction with 20 N of low initial tension yielded good clinical outcomes at 2 years postoperatively, and second-look arthroscopic findings were excellent. Level IV

  4. The Role of Bioreactors in Ligament and Tendon Tissue Engineering.

    Science.gov (United States)

    Mace, James; Wheelton, Andy; Khan, Wasim S; Anand, Sanj

    2016-01-01

    Bioreactors are pivotal to the emerging field of tissue engineering. The formation of neotissue from pluripotent cell lineages potentially offers a source of tissue for clinical use without the significant donor site morbidity associated with many contemporary surgical reconstructive procedures. Modern bioreactor design is becoming increasingly complex to provide a both an expandable source of readily available pluripotent cells and to facilitate their controlled differentiation into a clinically applicable ligament or tendon like neotissue. This review presents the need for such a method, challenges in the processes to engineer neotissue and the current designs and results of modern bioreactors in the pursuit of engineered tendon and ligament.

  5. Treatment of peroneal tendon dislocation and coexisting medial and lateral ligamentous laxity in the ankle joint.

    Science.gov (United States)

    Ziai, Pejman; Sabeti-Aschraf, Manuel; Fehske, Kai; Dlaska, Constantin E; Funovics, Philipp; Wenzel, Florian; Graf, Alexandra; Buchhorn, Tomas

    2011-06-01

    Acute dislocation of the peroneal tendon is caused by massive combined flexion-torsion trauma supported by preexisting ligamentous laxity of the ankle joint. This study aimed to investigate the clinical outcome of combined treatment of peroneal tendon dislocation and lateral and medial ligamentous laxity. Between 2005 and 2007, forty-two patients with peroneal tendon dislocation and coexisting ligamentous laxity were treated. The superior extensor retinaculum was reconstructed using anchor technique and periosteal flap repair, whereas the preexisting ligamentous laxity with regard to the extensor inferior retinaculum was addressed using anchor reconstruction. All patients underwent arthroscopy prior to surgery. Thirty-eight of a total of 42 patients (aged 17-31) completed the 24-month follow-up. Clinical and arthroscopic examination was accomplished consistently by always the same two surgeons. Postoperative follow-up comprised clinical evaluation after 3, 6, 12 and 24 months. Clinical results showed a significant (Pankle joint following arthroscopy results in good clinical outcome and high patient satisfaction. Case series, Level IV.

  6. Ulnar-sided pain due to extensor carpi ulnaris tendon subluxation: a case report

    Directory of Open Access Journals (Sweden)

    Cift Hakan

    2012-11-01

    Full Text Available Abstract Introduction We present the case of a patient with extensor carpi ulnaris tendon subluxation who was first treated for distal radioulnar joint sprain. Case presentation A 25-year-old Caucasian man was seen at our policlinic one month after he had fallen on his outstretched hand. A diagnosis of extensor carpi ulnaris subluxation was made clinically but we also had the magnetic resonance imaging scan of the patient’s wrist which displayed an increased signal on T2-weighted images consistent with inflammation around the extensor carpi ulnaris tendon. The extensor carpi ulnaris tendon was found to be dislocating during supination and relocating during pronation. The sheath was reconstructed using extensor retinaculum due to attenuation of subsheath. Conclusion There was no recurrent dislocation of the extensor carpi ulnaris tendon of the patient at his last follow up 12 months after the operation.

  7. Comparison of a novel bone-tendon allograft with a human dermis-derived patch for repair of chronic large rotator cuff tears using a canine model.

    Science.gov (United States)

    Smith, Matthew J; Cook, James L; Kuroki, Keiichi; Jayabalan, Prakash S; Cook, Cristi R; Pfeiffer, Ferris M; Waters, Nicole P

    2012-02-01

    This study tested a bone-tendon allograft versus human dermis patch for reconstructing chronic rotator cuff repair by use of a canine model. Mature research dogs (N = 15) were used. Radiopaque wire was placed in the infraspinatus tendon (IST) before its transection. Three weeks later, radiographs showed IST retraction. Each dog then underwent 1 IST treatment: debridement (D), direct repair of IST to bone with a suture bridge and human dermis patch augmentation (GJ), or bone-tendon allograft (BT) reconstruction. Outcome measures included lameness grading, radiographs, and ultrasonographic assessment. Dogs were killed 6 months after surgery and both shoulders assessed biomechanically and histologically. BT dogs were significantly (P = .01) less lame than the other groups. BT dogs had superior bone-tendon, tendon, and tendon-muscle integrity compared with D and GJ dogs. Biomechanical testing showed that the D group had significantly (P = .05) more elongation than the other groups whereas BT had stiffness and elongation characteristics that most closely matched normal controls. Radiographically, D and GJ dogs showed significantly more retraction than BT dogs (P = .003 and P = .045, respectively) Histologically, GJ dogs had lymphoplasmacytic infiltrates, tendon degeneration and hypocellularity, and poor tendon-bone integration. BT dogs showed complete incorporation of allograft bone into host bone, normal bone-tendon junctions, and well-integrated allograft tendon. The bone-tendon allograft technique re-establishes a functional IST bone-tendon-muscle unit and maintains integrity of repair in this model. Clinical trials using this bone-tendon allograft technique are warranted. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. Allograft tendon reconstruction of the anterior talofibular ligament and calcaneofibular Ligament in the treatment of chronic ankle instability.

    Science.gov (United States)

    Wang, Weikai; Xu, Guo Hong

    2017-04-08

    The purpose was retrospectively to investigate functional and clinical outcomes after anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL) reconstruction using a single allograft. Patients with severe chronic lateral instability of the ankle underwent surgery after conservative treatment failed. Ultrasounds of the ankle were performed, and if the AFTL and CFL were completely torn without enough soft tissue for repair, the ligaments were reconstructed using allograft tendon. Outcomes were assessed by clinical examination, stress radiography, ultrasound, the American Orthopaedic Foot and Ankle Society score (AOFAS), and Karlsson Ankle Functional score (KAFS) before surgery and at final follow-up. Nineteen patients, ten men and nine women with mean age of 27.9 years (range, 19-41 years), underwent reconstruction. Mean follow-up was 30 months (range, 24-40 months). At final follow-up, all patients had returned to activity without instability, pain, or limited range of motion. On stress radiography, mean talar tilt angle decreased from 17.32° ± 3.58° before surgery to 4.16° ± 1.12° at follow-up (p surgery to 3.97 ± 0.99 mm at follow-up (p < 0.05). Mean AOFAS improved from 64.00 ± 18.43 to 90.32 ± 5.17 points (p < 0.001), and mean KAFS improved from 50.84 ± 16.73 to 90.89 ± 5.08 points (p < 0.001). Ultrasound showed the reconstructed ligaments maintained good continuity and excellent tension. No case of infection and immunological rejection was reported. This novel reconstruction technique takes into account the anatomical specialty of AFTL and CFL. This case series showed increased stability of the ankle in clinical and functional outcomes. The trial registration number (TRN) and date of registration: ChiCTR-ORC-17010796 , Mar 6th 2017. Retrospectively registered.

  9. Total esophagogastrectomy plus extended lymphadenectomy with transverse colon interposition: A treatment for extensive esophagogastric junction cancer.

    Science.gov (United States)

    Ceroni, Marco; Norero, Enrique; Henríquez, Juan Pablo; Viñuela, Eduardo; Briceño, Eduardo; Martínez, Cristian; Aguayo, Gloria; Araos, Fernando; González, Paulina; Díaz, Alfonso; Caracci, Mario

    2015-10-08

    To review the post-operative morbidity and mortality of total esophagogastrectomy (TEG) with second barrier lymphadenectomy (D2) with interposition of a transverse colon and to determine the oncological outcomes of TEG D2 with interposition of a transverse colon. This study consisted of a retrospective review of patients with a cancer diagnosis who underwent TEG between 1997 and 2013. Demographic data, surgery protocols, complications according to Clavien-Dindo classifications, final pathological reports, oncological follow-ups and causes of death were recorded. We used the TNM 2010 and Japanese classifications for nodal dissection of gastric cancer. We used descriptive statistical analysis and Kaplan-Meier survival curves. A P-value of less than 0.05 was considered statistically significant. The series consisted of 21 patients (80.9% men). The median age was 60 years. The 2 main surgical indications were extensive esophagogastric junction cancers (85.7%) and double cancers (14.2%). The mean total surgery time was 405 min (352-465 min). Interposition of a transverse colon through the posterior mediastinum was used for replacement in all cases. Splenectomy was required in 13 patients (61.9%), distal pancreatectomy was required in 2 patients (9.5%) and resection of the left adrenal gland was required in 1 patient (4.7%). No residual cancer surgery was achieved in 75.1% of patients. A total of 71.4% of patients had a postoperative complication. Respiratory complications were the most frequently observed complication. Postoperative mortality was 5.8%. Median follow-up was 13.4 mo. Surgery specific survival at 5 years of follow-up was 32.8%; for patients with curative surgery, it was 39.5% at 5 years. TEG for cancer with interposition of a transverse colon is a very complex surgery, and it presents high post-operative morbidity and adequate oncological outcomes.

  10. Microsurgical reconstruction of extensive oncological scalp defects

    Directory of Open Access Journals (Sweden)

    Ole eGoertz

    2015-09-01

    Full Text Available While most small to medium defects of the scalp can be covered by local flaps, large defects or complicating factors like a history of radiotherapy often require a microsurgical reconstruction.Several factors need to be considered in such procedures. A sufficient preoperative planning is based on adequate imaging of the malignancy and a multi-disciplinary concept. Several flaps are available for such reconstructions, of which the latissimus dorsi and anterior lateral thigh flaps are the most commonly used ones.In very large defects, combined flaps such as a parascapular / latissimus dorsi flaps can be highly useful or necessary. The most commonly used recipient vessels for microsurgical scalp reconstructions are the superficial temporal vessels, but various other feasible choices exist. If the concomitant veins are not sufficient, the jugular veins represent a safe backup alternative but require a vessel interposition or long pedicle. Postoperative care and patient positioning can be difficult in these patients but can be facilitated by various devices. Overall, microsurgical reconstruction of large scalp defects is a feasible undertaking if the mentioned key factors are taken into account.

  11. Interpositional Gap Arthroplasty by Versatile Pedicled Temporalis Myofascial Flap in the Management of Temporomandibular Joint Ankylosis- A Case Series Study

    OpenAIRE

    Aneja, Vikas; Raval, Rushik; Bansal, Anupam; Kumawat, Vinod; Kaur, Jasleen; Shaikh, Ahemer Arif

    2016-01-01

    Temporomandibular Joint (TMJ) ankylosis is a situation in which the mandibular condyle is fused to the glenoid fossa by bone or fibrous tissue. The management of TMJ ankylosis has a complicated chore and it is challenging for the maxillofacial surgeon because of technical hitches and high rate of re-ankylosis. Interpositional gap arthroplasty is one of the modalities for its management. A range of inter-positional materials have been used to avert recurrence after gap arthroplasty in TMJ anky...

  12. FIBRILLINS IN TENDON

    Directory of Open Access Journals (Sweden)

    Betti Giusti

    2016-10-01

    Full Text Available Tendons among connective tissue, mainly collagen, contain also elastic fibres made of fibrillin 1, fibrillin 2 and elastin that are broadly distributed in tendons and represent 1-2% of the dried mass of the tendon. Only in the last years, studies on structure and function of elastic fibres in tendons have been performed. Aim of this review is to revise data on the organization of elastic fibres in tendons, in particular fibrillin structure and function, and on the clinical manifestations associated to alterations of elastic fibres in tendons. Indeed, microfibrils may contribute to tendon mechanics; therefore, their alterations may cause joint hypermobility and contractures which have been found to be clinical features in patients with Marfan syndrome and Beals syndrome. The two diseases are caused by mutations in genes FBN1 and FBN2 encoding fibrillin 1 and fibrillin 2, respectively.

  13. [Application of joint reconstruction with autogenous coronoid process graft to treat temporomandibular joint ankylosis].

    Science.gov (United States)

    Xie, Qing-tiao; Huang, Xuan-ping; Jiang, Xian-fang; Yang, Yuan-yuan; Li, Hua; Lin, Xi

    2013-08-01

    To evaluate the clinical effect of joint reconstruction by using autogenous coronoid process graft to treat temporomandibular joint(TMJ) ankylosis. Nine cases of TMJ ankylosis from September 2008 to September 2010 were surgically treated by joint reconstruction with autogenous coronoid process graft, using autogenous articular disc or prosthodontic membrane as interpositional material. Mouth opening, occlusion and cone beam CT(CBCT) were used for evaluation before and after surgery. Satisfactory mouth opening was achieved in all patients and no one got occlusal changes or reankylosis during follow-up. CBCT showed that coronoid process graft reached bone union with the ramus and turned to be round. It is effective to cure TMJ ankylosis through joint reconstruction with autogenous coronoid process graft.

  14. The role of three-dimensional pure bovine gelatin scaffolds in tendon healing, modeling, and remodeling: an in vivo investigation with potential clinical value.

    Science.gov (United States)

    Oryan, Ahmad; Sharifi, Pardis; Moshiri, Ali; Silver, Ian A

    2017-09-01

    Large tendon defects involving extensive tissue loss present complex clinical problems. Surgical reconstruction of such injuries is normally performed by transplanting autogenous and allogenous soft tissues that are expected to remodel to mimic a normal tendon. However, the use of grafts has always been associated with significant limitations. Tissue engineering employing artificial scaffolds may provide acceptable alternatives. Gelatin is a hydrolyzed form of collagen that is bioactive, biodegradable, and biocompatible. The present study has investigated the suitability of gelatin scaffold for promoting healing of a large tendon-defect model in rabbits. An experimental model of a large tendon defect was produced by partial excision of the Achilles tendon of the left hind leg in adult rabbits. To standardize and stabilize the length of the tendon defect a modified Kessler core suture was anchored in the sectioned tendon ends. The defects were either left untreated or filled with three-dimensional gelatin scaffold. Before euthanasia 60 days after injury, the progress of healing was evaluated clinically. Samples of healing tendon were harvested at autopsy and evaluated by gross, histopathologic, scanning, and transmission electron microscopy, and by biomechanical testing. The treated animals showed superior weight-bearing and physical activity compared with those untreated, while frequency of peritendinous adhesions around the healing site was reduced. The gelatin scaffold itself was totally degraded and replaced by neo-tendon that morphologically had significantly greater numbers, diameters, density, and maturation of collagen fibrils, fibers, and fiber bundles than untreated tendon scar tissue. It also had mechanically higher ultimate load, yield load, stiffness, maximum stress and elastic modulus, when compared to the untreated tendons. Gelatin scaffold may be a valuable option in surgical reconstruction of large tendon defects.

  15. Coracoclavicular ligament reconstruction with the autogenous anterior half of the peroneus longus tendon for distal clavicle fracture (Neer type Ⅱ-b: A report of 26 cases

    Directory of Open Access Journals (Sweden)

    Guang-you YANG

    2017-12-01

    Full Text Available Objective To explore the clinical effect of coracoclavicular ligament reconstruction with the autogenous anterior half of peroneus longus tendon (AHPLT for distal clavicle fracture (Neer type Ⅱ-b. Methods The clinical data were retrospectively analyzed of 26 Neer type Ⅱ-b distal clavicle fracture surgically treated by coracoclavicular ligament reconstruction with autogenous AHPLT in Ganyu District People's Hospital of Lianyungang from June 2012 to May 2015. Among the 26 cases, 16 males and 10 females, aged from 19-56 years (average 38.7 years. Fracture occurred in left side in 18 cases and in right side in 8 cases. Postoperative observations were done on fracture healing, shoulder and ankle-foot function recovery. Results For all the 26 cases, surgical incisions were healed well, and no infection, vascular and peroneal nerve injury and iatrogenic fracture occurred. Follow-up was carried out for 10-24 months with average of 15.3 months. All the fractures were healed within 12-20 weeks with an average of 14.6 weeks. One patient was found of losing the fracture reduction part during the follow-up process, and then got eventual healing by extending the limb brake time. Another patient was found of slight tendon sensation disorder with no significant effect on daily life and exercise, and the symptoms disappeared 6 months later. At the last follow-up, the Constant-Murley score was 92-100 with an average of 97.8 points. The ankle-hind foot score of American Society of Ankle and Orthopedics was excellent. Conclusion Reconstruction of coracoclavicular ligament with autogenous AHPLT is an effective treatment for Neer type Ⅱ-b distal clavicle fracture with good safety and without negative effect on the ankle-foot function, and thus it is worthy of wider clinical use. DOI: 10.11855/j.issn.0577-7402.2017.12.12

  16. Repair of full-thickness tendon injury using connective tissue progenitors efficiently derived from human embryonic stem cells and fetal tissues.

    Science.gov (United States)

    Cohen, Shahar; Leshansky, Lucy; Zussman, Eyal; Burman, Michael; Srouji, Samer; Livne, Erella; Abramov, Natalie; Itskovitz-Eldor, Joseph

    2010-10-01

    The use of stem cells for tissue engineering (TE) encourages scientists to design new platforms in the field of regenerative and reconstructive medicine. Human embryonic stem cells (hESC) have been proposed to be an important cell source for cell-based TE applications as well as an exciting tool for investigating the fundamentals of human development. Here, we describe the efficient derivation of connective tissue progenitors (CTPs) from hESC lines and fetal tissues. The CTPs were significantly expanded and induced to generate tendon tissues in vitro, with ultrastructural characteristics and biomechanical properties typical of mature tendons. We describe a simple method for engineering tendon grafts that can successfully repair injured Achilles tendons and restore the ankle joint extension movement in mice. We also show the CTP's ability to differentiate into bone, cartilage, and fat both in vitro and in vivo. This study offers evidence for the possibility of using stem cell-derived engineered grafts to replace missing tissues, and sets a basic platform for future cell-based TE applications in the fields of orthopedics and reconstructive surgery.

  17. Active Achilles tendon kinesitherapy accelerates Achilles tendon repair by promoting neurite regeneration.

    Science.gov (United States)

    Jielile, Jiasharete; Aibai, Minawa; Sabirhazi, Gulnur; Shawutali, Nuerai; Tangkejie, Wulanbai; Badelhan, Aynaz; Nuerduola, Yeermike; Satewalede, Turde; Buranbai, Darehan; Hunapia, Beicen; Jialihasi, Ayidaer; Bai, Jingping; Kizaibek, Murat

    2012-12-15

    Active Achilles tendon kinesitherapy facilitates the functional recovery of a ruptured Achilles tendon. However, protein expression during the healing process remains a controversial issue. New Zealand rabbits, aged 14 weeks, underwent tenotomy followed immediately by Achilles tendon microsurgery to repair the Achilles tendon rupture. The tendon was then immobilized or subjected to postoperative early motion treatment (kinesitherapy). Mass spectrography results showed that after 14 days of motion treatment, 18 protein spots were differentially expressed, among which, 12 were up-regulated, consisting of gelsolin isoform b and neurite growth-related protein collapsing response mediator protein 2. Western blot analysis showed that gelsolin isoform b was up-regulated at days 7-21 of motion treatment. These findings suggest that active Achilles tendon kinesitherapy promotes the neurite regeneration of a ruptured Achilles tendon and gelsolin isoform b can be used as a biomarker for Achilles tendon healing after kinesitherapy.

  18. Active Achilles tendon kinesitherapy accelerates Achilles tendon repair by promoting neurite regeneration☆

    Science.gov (United States)

    Jielile, Jiasharete; Aibai, Minawa; Sabirhazi, Gulnur; Shawutali, Nuerai; Tangkejie, Wulanbai; Badelhan, Aynaz; Nuerduola, Yeermike; Satewalede, Turde; Buranbai, Darehan; Hunapia, Beicen; Jialihasi, Ayidaer; Bai, Jingping; Kizaibek, Murat

    2012-01-01

    Active Achilles tendon kinesitherapy facilitates the functional recovery of a ruptured Achilles tendon. However, protein expression during the healing process remains a controversial issue. New Zealand rabbits, aged 14 weeks, underwent tenotomy followed immediately by Achilles tendon microsurgery to repair the Achilles tendon rupture. The tendon was then immobilized or subjected to postoperative early motion treatment (kinesitherapy). Mass spectrography results showed that after 14 days of motion treatment, 18 protein spots were differentially expressed, among which, 12 were up-regulated, consisting of gelsolin isoform b and neurite growth-related protein collapsing response mediator protein 2. Western blot analysis showed that gelsolin isoform b was up-regulated at days 7–21 of motion treatment. These findings suggest that active Achilles tendon kinesitherapy promotes the neurite regeneration of a ruptured Achilles tendon and gelsolin isoform b can be used as a biomarker for Achilles tendon healing after kinesitherapy. PMID:25317130

  19. Experimental and Numerical Analysis of Screw Fixation in Anterior Cruciate Ligament Reconstruction

    Science.gov (United States)

    Chizari, Mahmoud; Wang, Bin; Snow, Martyn; Barrett, Mel

    2008-09-01

    This paper reports the results of an experimental and finite element analysis of tibial screw fixation in anterior cruciate ligament (ACL) reconstruction. The mechanical properties of the bone and tendon graft are obtained from experiments using porcine bone and bovine tendon. The results of the numerical study are compared with those from mechanical testing. Analysis shows that the model may be used to establish the optimum placement of the tunnel in anterior cruciate ligament reconstruction by predicting mechanical parameters such as stress, strain and displacement at regions in the tunnel wall.

  20. CT-control of the H-graft interposition mesocaval shunt patency

    Energy Technology Data Exchange (ETDEWEB)

    Partanen, P L.K.; Oksala, I

    1984-02-01

    A method for assessing the patency of the H-graft interposition mesocaval shunts by computerized tomography is described. Five patients with such shunts were examined with a 5.5 second CT scanner. After locating the graft a 50 cc bolus of 76% diatrizoate was injected into a cubital vein and 3-4 scans were executed at a preselected level. A distinct vessel like enhancement appeared if the shunt was open. With dynamic CT-scanning the flow can be demonstrated in graphical form as time-density curves.

  1. Tendon Transfer Surgery

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... DESCRIPTION The tendon is the strong cord at either end of a muscle that is attached to bone. Tendons , combined with ...

  2. The use of bovine pericardial patch for vascular reconstruction in infected fields for transplant recipients

    Directory of Open Access Journals (Sweden)

    Sandra Garcia Aroz, MD

    2017-03-01

    Full Text Available Infectious vascular complications affecting transplant recipients may lead to severe morbidity and graft loss. This is a retrospective review of vascular repair with bovine pericardial patch (BPP in infected fields for immunosuppressed patients. BPP was used as either a patch or an interposition graft. Five cases of arterial reconstruction in infected fields using BPP were performed. There were no complications related to bleeding, thrombosis, or recurrent infection. In our limited experience, the use of BPP as a vascular patch is successful, and it represents an alternative when vascular reconstruction is needed in the context of infected fields.

  3. A Pilot Study of Common Bile Duct Reconstruction with CorMatrix Extracellular Matrix in Swine (Sus scrofa)

    Science.gov (United States)

    2015-02-06

    additional pages if necessary.) PROTOCOL#: FDG20140008A DATE: 6 February 2015 PROTOCOL TITLE: A Pilot Study of Common Bile Duct Reconstruction with...obstruction or bile peritonitis. This was reported to the IACUC chair. 9. REDUCTION, REFINEMENT, OR REPLACEMENT OF ANIMAL USE; REPLACEMENT...benefit the DoD/USAF? We developed a porcine model of common bile duct injury and interposition grafting, gained experience managing these patients

  4. Condition Assessment of PC Tendon Duct Filling by Elastic Wave Velocity Mapping

    Directory of Open Access Journals (Sweden)

    Kit Fook Liu

    2014-01-01

    Full Text Available Imaging techniques are high in demand for modern nondestructive evaluation of large-scale concrete structures. The travel-time tomography (TTT technique, which is based on the principle of mapping the change of propagation velocity of transient elastic waves in a measured object, has found increasing application for assessing in situ concrete structures. The primary aim of this technique is to detect defects that exist in a structure. The TTT technique can offer an effective means for assessing tendon duct filling of prestressed concrete (PC elements. This study is aimed at clarifying some of the issues pertaining to the reliability of the technique for this purpose, such as sensor arrangement, model, meshing, type of tendon sheath, thickness of sheath, and material type as well as the scale of inhomogeneity. The work involved 2D simulations of wave motions, signal processing to extract travel time of waves, and tomography reconstruction computation for velocity mapping of defect in tendon duct.

  5. Achilles Tendonitis

    Science.gov (United States)

    ... almost impossible. Achilles tendonitis is a very common running injury. But it can also affect basketball players, dancers, ... Proximal Biceps Tendonitis Safety Tips: Basketball Safety Tips: Running Repetitive Stress Injuries Sports and Exercise Safety Dealing With Sports Injuries ...

  6. Magnetic resonance imaging findings of periosteal interposition in a distal tibial Salter-Harris type I fracture with surgical correlation: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Nara; Jung, Jee Young; Kang, Ki Ser [Chung-Ang University Hospital, Seoul (Korea, Republic of)

    2013-08-15

    The complication of growth disturbance after physeal fracture of the distal tibia has been well recognized. Although irreducible fractures of the physis due to trapped soft tissue, including periosteum, are not common, it could still cause growth disturbances. Therefore, the detection of periosteal interposition with physeal injury on imaging study is important. We present a case of a 10-year-old girl with surgically confirmed periosteal interposition in the distal tibial Salter-Harris type I fracture, through magnetic resonance imaging findings.

  7. Magnetic resonance imaging findings of periosteal interposition in a distal tibial Salter-Harris type I fracture with surgical correlation: A case report

    International Nuclear Information System (INIS)

    Kim, Nara; Jung, Jee Young; Kang, Ki Ser

    2013-01-01

    The complication of growth disturbance after physeal fracture of the distal tibia has been well recognized. Although irreducible fractures of the physis due to trapped soft tissue, including periosteum, are not common, it could still cause growth disturbances. Therefore, the detection of periosteal interposition with physeal injury on imaging study is important. We present a case of a 10-year-old girl with surgically confirmed periosteal interposition in the distal tibial Salter-Harris type I fracture, through magnetic resonance imaging findings.

  8. Mechanical Properties of Human Patellar Tendon at the Hierarchical levels of Tendon and Fibril

    DEFF Research Database (Denmark)

    Svensson, Rene Brüggebusch; Hansen, Philip; Hassenkam, Tue

    2012-01-01

    Tendons are strong hierarchical structures, but how tensile forces are transmitted between different levels remains incompletely understood. Collagen fibrils are thought to be primary determinants of whole tendon properties, and therefore we hypothesized that the whole human patellar tendon and its...... distinct collagen fibrils would display similar mechanical properties. Human patellar tendons (n=5) were mechanically tested in vivo by ultrasonography. Biopsies were obtained from each tendon and individual collagen fibrils were dissected and tested mechanically by atomic force microscopy. The Young...... that of tendon supports that fibrillar rather than interfibrillar properties govern sub-failure tendon response, making the fibrillar level a meaningful target of intervention. The lower modulus found in vitro suggests a possible adverse effect of removing the tissue from its natural environment. In addition...

  9. Fibroma of the tendon sheath of the long head of the biceps tendon

    International Nuclear Information System (INIS)

    Maeseneer, Michel de; Shahabpour, Maryam; Isacker, Tom van; Lenchik, Leon; Caillie, Marie-Astrid van

    2014-01-01

    Fibroma of the tendon sheath is a benign tumor that is less common than giant cell tumor of the tendon sheath. Both tumors may present as a painless, slowly enlarging mass. Radiological findings may be similar for both tumors. Histologically, fibroma of the tendon sheath lacks the hemosiderin-laden macrophages that are typical for giant cell tumor of the tendon sheath. We report on a 49-year-old woman with fibroma of the tendon sheath of the long head of the biceps tendon. In our case, on MR images, we observed band-like hypointense areas centrally in the tumor, mild patchy contrast enhancement, and most importantly, no decrease of signal intensity on gradient echo images. These characteristics reflected histological findings. (orig.)

  10. Ropivacaine alters the mechanical properties of hamstring tendons: In vitro controlled mechanical testing of tendons from living donors.

    Science.gov (United States)

    Ollivier, M; Sbihi, J; Sbihi, A; Pithioux, M; Parratte, S; Argenson, J-N

    2017-11-01

    Intraarticular or periarticular injection of ropivacaine (RI) is an element of current knee surgery practices. The goal of this study was to determine the effects of RI on the mechanical properties of hamstring tendons. We hypothesized that RI would have a detrimental effect on the mechanical properties of periarticular soft tissues METHODS: A tensile test to failure was performed on 120 hamstring tendon segments harvested during ACL reconstruction surgery in 120 patients. Two sets of tensile tests were done. The first evaluated the effect of RI itself on the mechanical properties of tendons: 30 samples were soaked for 1hour in a 2% RI solution and compared to 30 samples soaked in a saline solution (control group). The second evaluated the effect of RI concentration on the mechanical properties of hamstring tendons: 30 samples were soaked for 1hour in a 2% RI solution and 30 samples were soaked in a 7.5% RI solution. In the first test, 29 samples from each group were analyzed as two samples (one in each group) failed at the grip interface. The specimens exposed to 2% RI had lower ultimate tensile strength (Δ=4.4MPa, P=0.001), strain energy (Δ=13MPa, P=0.001) and Young's modulus (Δ=1.6MPa, P=0.02) than the specimens in the control group. There was no significant difference in the strain at failure between groups (Δ=5%, P=0.3). In the second test, one specimen from the 7.5% RI group failed during the preloading and was excluded. There was no significant difference in terms of the load at failure and ultimate tensile stress (Δ=0.45MPa, P=0.6) and strain energy (Δ=0.49MPa, P=0.49) between the two groups. There were significant differences in terms of elongation at failure (Δ=28%, P=0.0003) and Young's modulus (Δ=2.6MPa, P=0.005), with the specimens exposed to 7.5% RI undergoing greater deformation and having a lower Young's modulus. While local RI injections are widely performed in clinical practice, the results of this in vitro study point to short

  11. Achilles tendon and sports

    International Nuclear Information System (INIS)

    Ulreich, N.; Kainberger, F.; Huber, W.; Nehrer, S.

    2002-01-01

    Because of the rising popularity of recreational sports activities achillodynia is an often associated symptom with running, soccer and athletics. Therefore radiologist are frequently asked to image this tendon. The origin of the damage of the Achilles tendon is explained by numerous hypothesis, mainly a decreased perfusion and a mechanical irritation that lead to degeneration of the tendon. High-resolution technics such as sonography and magnetic resonance imaging show alterations in the structure of the tendon which can be graduated and classified. Manifestations like tendinosis, achillobursitis, rupture and Haglunds disease can summarized as the tendon overuse syndrom. A rupture of a tendon is mostly the result of a degeneration of the collagenfibres. The task of the radiologist is to acquire the intrinsic factors for a potential rupture. (orig.) [de

  12. Epidural fat interposition between dura mater and spinous process: a new sign for the diagnosis of spondylolysis on MR imaging of the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Sherif, Hanan; Mahfouz, Ahmed-Emad [Department of Radiology, Hamad Medical Corporation, P.O. Box 3050, Doha (Qatar)

    2004-06-01

    The purpose of this study was to assess the diagnostic value of epidural fat interposition between the dura mater and spinous process of L5 as an indirect sign of spondylolysis on mid-sagittal MR imaging of the lumbar spine. Mid-sagittal T1-weighted MR images of the lumbar spine of 85 patients with spondylolysis and 93 patients without pars interarticularis fractures were randomized and evaluated by a masked reader. After a training sample of five cases, the reader was asked to note the presence or absence of epidural fat interposition between the dura mater and spinous process of L5 on the randomized images. The epidural fat interposition between the dura mater and spinous process of L5 was noted in 67 out of the 85 patients with spondylolysis (78.8%) and three of the patients without pars interarticularis fracture (3.2%). The difference was statistically significant (P<0.01). This sign has a specificity of 96.7%, sensitivity of 78.8%, positive predictive value of 95.7%, negative predictive value of 83.3% and accuracy of 88.2% for diagnosis of spondylolysis. Epidural fat interposition between the dura mater and spinous process may be a helpful sign for the diagnosis of spondylolysis on mid-sagittal MR imaging of the lumbar spine. (orig.)

  13. Epidural fat interposition between dura mater and spinous process: a new sign for the diagnosis of spondylolysis on MR imaging of the lumbar spine

    International Nuclear Information System (INIS)

    Sherif, Hanan; Mahfouz, Ahmed-Emad

    2004-01-01

    The purpose of this study was to assess the diagnostic value of epidural fat interposition between the dura mater and spinous process of L5 as an indirect sign of spondylolysis on mid-sagittal MR imaging of the lumbar spine. Mid-sagittal T1-weighted MR images of the lumbar spine of 85 patients with spondylolysis and 93 patients without pars interarticularis fractures were randomized and evaluated by a masked reader. After a training sample of five cases, the reader was asked to note the presence or absence of epidural fat interposition between the dura mater and spinous process of L5 on the randomized images. The epidural fat interposition between the dura mater and spinous process of L5 was noted in 67 out of the 85 patients with spondylolysis (78.8%) and three of the patients without pars interarticularis fracture (3.2%). The difference was statistically significant (P<0.01). This sign has a specificity of 96.7%, sensitivity of 78.8%, positive predictive value of 95.7%, negative predictive value of 83.3% and accuracy of 88.2% for diagnosis of spondylolysis. Epidural fat interposition between the dura mater and spinous process may be a helpful sign for the diagnosis of spondylolysis on mid-sagittal MR imaging of the lumbar spine. (orig.)

  14. Partial trapeziectomy and interposition of fascia lata allograft in the operative treatment of thumb base osteoarthritis

    NARCIS (Netherlands)

    Spaans, Anne J.; Weijns, Marieke E.; Braakenburg, Assa; Van Minnen, Leo Paul; Mink Van Der Molen, Aebele B.

    2016-01-01

    Aim: The purpose of this retrospective cohort study was to evaluate the results of fascia lata allograft interposition after partial trapeziectomy in patients with symptomatic first carpometacarpal joint osteoarthritis. Methods and results: Twenty-one patients (22 thumbs) with Eaton-Glickel stage II

  15. Augmentation of Rotator Cuff Repair With Soft Tissue Scaffolds

    Science.gov (United States)

    Thangarajah, Tanujan; Pendegrass, Catherine J.; Shahbazi, Shirin; Lambert, Simon; Alexander, Susan; Blunn, Gordon W.

    2015-01-01

    Background Tears of the rotator cuff are one of the most common tendon disorders. Treatment often includes surgical repair, but the rate of failure to gain or maintain healing has been reported to be as high as 94%. This has been substantially attributed to the inadequate capacity of tendon to heal once damaged, particularly to bone at the enthesis. A number of strategies have been developed to improve tendon-bone healing, tendon-tendon healing, and tendon regeneration. Scaffolds have received considerable attention for replacement, reconstruction, or reinforcement of tendon defects but may not possess situation-specific or durable mechanical and biological characteristics. Purpose To provide an overview of the biology of tendon-bone healing and the current scaffolds used to augment rotator cuff repairs. Study Design Systematic review; Level of evidence, 4. Methods A preliminary literature search of MEDLINE and Embase databases was performed using the terms rotator cuff scaffolds, rotator cuff augmentation, allografts for rotator cuff repair, xenografts for rotator cuff repair, and synthetic grafts for rotator cuff repair. Results The search identified 438 unique articles. Of these, 214 articles were irrelevant to the topic and were therefore excluded. This left a total of 224 studies that were suitable for analysis. Conclusion A number of novel biomaterials have been developed into biologically and mechanically favorable scaffolds. Few clinical trials have examined their effect on tendon-bone healing in well-designed, long-term follow-up studies with appropriate control groups. While there is still considerable work to be done before scaffolds are introduced into routine clinical practice, there does appear to be a clear indication for their use as an interpositional graft for large and massive retracted rotator cuff tears and when repairing a poor-quality degenerative tendon. PMID:26665095

  16. MR evaluation of the knee following anterior cruciate ligament reconstruction

    International Nuclear Information System (INIS)

    Rak, K.M.; Gillogly, S.D.; Schaefer, R.A.; Yakes, W.F.

    1991-01-01

    This paper evaluates the role of MR imaging of the knee after anterior cruciate ligament (ACL) reconstruction. Seventy-five MR examinations were performed in 52 patients following ACL reconstruction with patellar tendon autografts. MR imaging demonstrated a well-defined autograft in 63 of 70 clinically stable autografts. Of 5 clinically lax reconstructions, none appeared will defined on MR images. Compared with the clinical examination, MR imaging was 90.7% accurate. MR imaging demonstrated time-related healing of the patellar tendon donor site, with persistent thickening indicative of tendinitis. Positions of the femoral and tibial bone tunnels could be assessed. Knee joint effusions tended to resolve completely within 7 months after operations, with the presence and degree of effusion in the earlier postoperative interval being unrelated to the clinical outcome. Ancillary disorders in the knee, such as meniscal tears and osteochondral defects, could also be evaluated in this postoperative population

  17. An artificial tendon with durable muscle interface.

    Science.gov (United States)

    Melvin, Alan; Litsky, Alan; Mayerson, Joel; Witte, David; Melvin, David; Juncosa-Melvin, Natalia

    2010-02-01

    A coupling mechanism that can permanently fix a forcefully contracting muscle to a bone anchor or any totally inert prosthesis would meet a serious need in orthopaedics. Our group developed the OrthoCoupler device to satisfy these demands. The objective of this study was to test OrthoCoupler's performance in vitro and in vivo in the goat semitendinosus tendon model. For in vitro evaluation, 40 samples were fatigue-tested, cycling at 10 load levels, n = 4 each. For in vivo evaluation, the semitendinosus tendon was removed bilaterally in eight goats. Left sides were reattached with an OrthoCoupler, and right sides were reattached using the Krackow stitch with #5 braided polyester sutures. Specimens were harvested 60 days postsurgery and assigned for biomechanics and histology. Fatigue strength of the devices in vitro was several times the contractile force of the semitendinosus muscle. The in vivo devices were built equivalent to two of the in vitro devices, providing an additional safety factor. In strength testing at necropsy, suture controls pulled out at 120.5 +/- 68.3 N, whereas each OrthoCoupler was still holding after the muscle tore, remotely, at 298 +/- 111.3 N (mean +/- SD) (p < 0.0003). Muscle tear strength was reached with the fiber-muscle composite produced in healing still soundly intact. This technology may be of value for orthopaedic challenges in oncology, revision arthroplasty, tendon transfer, and sports-injury reconstruction. (c) 2009 Orthopaedic Research Society.

  18. Calcaneal tendon: imaging findings

    International Nuclear Information System (INIS)

    Montandon, Cristiano; Fonseca, Cristiano Rezio; Montandon Junior, Marcelo Eustaquio; Lobo, Leonardo Valadares; Ribeiro, Flavia Aparecida de Souza; Teixeira, Kim-Ir-Sen Santos

    2003-01-01

    We reviewed the radiological and clinical features of 23 patients with calcaneal tendon diseases, who were submitted to ultrasound or magnetic resonance imaging. The objective of this study was to characterize the lesions for a precise diagnosis of calcaneal tendon injuries. A wide range of calcaneal tendon diseases include degenerative lesions, inflammation of the peritendinous tissue such as peritendinitis and bursitis, and rupture. Imaging methods are essential in the diagnosis, treatment and follow-up of calcaneal tendon diseases. (author)

  19. Over-the-top ACL Reconstruction Plus Extra-articular Lateral Tenodesis With Hamstring Tendon Grafts: Prospective Evaluation With 20-Year Minimum Follow-up.

    Science.gov (United States)

    Zaffagnini, Stefano; Marcheggiani Muccioli, Giulio Maria; Grassi, Alberto; Roberti di Sarsina, Tommaso; Raggi, Federico; Signorelli, Cecilia; Urrizola, Francisco; Spinnato, Paolo; Rimondi, Eugenio; Marcacci, Maurilio

    2017-12-01

    There are few published studies with very long-term follow-up of combined intra- and extra-articular anterior cruciate ligament (ACL) reconstruction. To analyze clinical and radiographic outcomes of over-the-top ACL reconstruction plus extra-articular lateral tenodesis with autologous hamstrings at minimum 20-year follow-up. Case series; Level of evidence, 4. Of 60 originally eligible patients who underwent over-the-top ACL reconstruction with double-stranded hamstring tendon (leaving intact graft tibial insertions) and extra-articular lateral plasty (performed with the remnant part of tendons), 52 were prospectively evaluated at a minimum 20-year follow-up (mean follow-up, 24 years; 41 men, 11 women; mean age at time of surgery, 25.5 ± 7.6 years). Twenty-nine patients were available for prospective evaluations: clinical (Lysholm, Tegner, and objective International Knee Documentation Committee [IKDC]), instrumented (KT-2000), and radiographic (standard, long-standing, and Merchant views). Subjective KOOS (Knee injury and Osteoarthritis Outcome Score) and objective inertial sensor pivot-shift analysis (KiRA) were carried out at final follow-up. Twenty-three patients were investigated by phone interview for subjective Tegner score and documented complications, rerupture, or revision surgery. At final follow-up, mean Lysholm score was 85.7 ± 14.6; median Tegner score, 4 (range, 3-5); sport activity resumption, 86.2%; and objective IKDC score, good or excellent in 86% of patients (31%, A; 55%, B). Only 3 of 26 patients (12%) had >5-mm manual maximum KT-2000 side-to-side difference. KiRA system documented positive pivot-shift (>0.9-m/s 2 tibial acceleration side-to-side difference) in these 3 of 26 patients (12%). Statistically significant changes were as follows: decrease in Tegner score from 7 (range, 6-8) at 5-year follow-up to 4 (range, 3-5) at 10 years ( P < .0001) and decrease in Lysholm score from 96.1 ± 7.3 at 10-year follow-up to 85.7 ± 14.6 at 20 years

  20. Containment structure tendon investigation

    International Nuclear Information System (INIS)

    Fulton, J.F.; Murray, K.H.

    1983-01-01

    The paper describes an investigation into the possible causes of lower-than-predicted tendon forces which were measured during past tendon surveillances for a concrete containment. The containment is post tensioned by vertical tendons which are anchored into a rock foundation. The tendons were originally stressed in 1969, and lift-off tests were performed on six occasions subsequent to this date over a period of 11 years. The tendon forces measured in these tests were generally lower than predicted, and by 1979 the prestress level in the containment was only marginally above the design requirement. The tendons were retensioned in 1980, and by this time an investigation into the possible causes was underway. Potential causes investigated include the rock anchors and surrounding rock, elastomeric pad creep, wire stresses, thermal effects, stressing equipment and lift-off procedures, and wire stress relaxation. The investigation activities included stress relaxation testing of wires pulled from actual tendons. The stress relaxation test program included wire specimens at several different temperature and initial stress levels and the effect of a varying temperature history on the stress relaxation property of the wires. For purpose of future force predictions of the retensioned tendons, the test program included tests to determine the effect on stress relaxation due to restressing the wires after they had relaxed for 1000 hours and 10,000 hours. (orig./GL)

  1. Highly Unusual Tendon Abnormality: Spontaneous Rupture of the Distal Iliopsoas Tendon

    Directory of Open Access Journals (Sweden)

    Gokcen Coban

    2014-06-01

    Full Text Available Iliopsoas tendon injuries are not common and usually occur due to avulsion of the iliopsoas tendon with detachment of the lesser trochanter, secondary to an athletic injury or trauma. In the absence of a trauma, avulsion of the lesser trochanter in an adult is regarded as a sign of metastatic disease until proven otherwise. Complete iliopsoas tendon tears have thus far only been described in elderly women, and without trauma or an underlying systemic disease, a hormonal basis may be a reason for the gender differences. In this article, we present an 87-year-old woman with spontaneous rupture of the left distal iliopsoas tendon unassociated with fracture of the lesser trochanter and in the absence of a recent trauma history. This elderly patient presented with acute groin pain and normal plain radiographs. Magnetic resonance imaging must be kept in mind as a modality of choice for identifying iliopsoas tendon abnormalities.

  2. [Achilles tendon rupture].

    Science.gov (United States)

    Thermann, H; Hüfner, T; Tscherne, H

    2000-03-01

    The treatment of acute of Achilles tendon rupture experienced a dynamic development in the last ten years. Decisive for this development was the application of MRI and above all the ultrasonography in the diagnostics of the pathological changes and injuries of tendons. The question of rupture morphology as well as different courses of healing could be now evaluated objectively. These advances led consequently to new modalities in treatment concepts and rehabilitation protocols. The decisive input for improvements of the outcome results and particularly the shortening of the rehabilitation period came with introduction of the early functional treatment in contrast to immobilizing plaster treatment. In a prospective randomized study (1987-1989) at the Trauma Dept. of the Hannover Medical School could show no statistical differences comparing functional non-operative with functional operative therapy with a special therapy boot (Variostabil/Adidas). The crucial criteria for therapy selection results from the sonographically measured position of the tendon stumps in plantar flexion (20 degrees). With complete adaptation of the tendons' ends surgical treatment does not achieve better results than non-operative functional treatment in term of tendon healing and functional outcome. Regarding the current therapeutic standards each method has is advantages and disadvantages. Both, the operative and non-operative functional treatment enable a stable tendon healing with a low risk of re-rupture (1-2%). Meanwhile there is consensus for early functional after-treatment of the operated Achilles' tendons. There seems to be a trend towards non-operative functional treatment in cases of adequate sonographical findings, or to minimal invasive surgical techniques.

  3. Structural tendon changes in patients with acromegaly: assessment of Achilles tendon with sonoelastography.

    Science.gov (United States)

    Onal, Eda Demil; Ipek, Ali; Evranos, Berna; Idilman, Ilkay Sedakat; Cakir, Bekir; Ersoy, Reyhan

    2016-03-01

    To describe the sonoelastographic appearance of the Achilles tendon in acromegalic patients and to determine whether the blood concentrations of growth hormone (GH) and insulin-like growth factor (IGF-1) are associated with the various sonographic elasticity types of Achilles tendons. Eighty-four Achilles tendons of 42 acromegaly patients and 84 Achilles tendons of 42 healthy volunteers were assessed with sonoelastography. The tendons were classified into two main types according to the elasticity features: type 1 blue/green (hard tissue) and type 2 yellow/red within green (intermediate-soft tissue). Two subtypes of these types were also defined. According to the definition, the elasticity of the tissue was in a spectrum ranging from hard to soft as the type progressed from 1a to 2b. The mean thickness of Achilles tendons in patients with acromegaly was significantly higher compared with healthy Achilles tendons (5.1+/-0.7 mm vs. 4.4+/-0.5, pacromegaly patients had type 2 sonoelastographic appearance of the Achilles tendon (124/252 third; 49.2% vs. 81/252 third; 32.1%, p=0.0001). Activity status of acromegaly and GH/IGF-I levels were similar in patients with different types of elasticity (p>0.05). Sonoelastography revealed structural changes in the tendinous tissue of patients with acromegaly, but it was not sensitive enough to reflect changes in the serum levels of GH/IGF-1.

  4. Trapezium excision and suture suspensionplasty (TESS) for the treatment of thumb carpometacarpal arthritis.

    Science.gov (United States)

    Putnam, Matthew D; Meyer, Nicholas J; Baker, Daniel; Brehmer, Jess; Carlson, Brent D

    2014-06-01

    Basilar thumb arthritis, or first carpometacarpal arthritis, is a common condition affecting older women and some men. It is estimated that as many as one third of postmenopausal woman are affected. Surgical treatment of this condition includes options ranging from arthrodesis to prosthetic arthroplasty. Intermediate options include complete or partial trapezial excision with or without interposition of a cushioning/stabilizing material (auto source, allo source, synthetic source). A multitude of methods appear to offer similar end results, although some methods definitely involve more surgical work and perhaps greater patient risk. Through retrospective evaluation of a cohort of patients who underwent suture suspensionplasty, we determined the postoperative effect on strength, motion, patient satisfaction, complications, and radiographic maintenance of the scaphoid-metacarpal distance. This review shows the method to be clinically effective and, by comparison with a more traditional ligament reconstruction trapezial interposition arthroplasty, the method does not require use of autograft or allograft tendon and has fewer surgical steps. Forty-four patients were included in this retrospective study. The results showed that 91% of patients were satisfied with the procedure. Pinch and grip strength remained the same preoperatively and postoperatively. A Disabilities of the Arm, Shoulder, and Hand patient-reported outcome instrument (DASH) scores averaged 30 at final follow-up. Three patients developed a late complication requiring further surgical intervention. In summary, this technique appears to be technically reproducible, requires no additional tendon material, and achieves objectively and subjectively similar results to other reported procedures used to manage first CMC Arthritis.

  5. MRI of tibialis anterior tendon rupture

    International Nuclear Information System (INIS)

    Gallo, Robert A.; DeMeo, Patrick J.; Kolman, Brett H.; Daffner, Richard H.; Sciulli, Robert L.; Roberts, Catherine C.

    2004-01-01

    Ruptures of the tibialis anterior tendon are rare. We present the clinical histories and MRI findings of three recent male patients with tibialis anterior tendon rupture aged 58-67 years, all of whom presented with pain over the dorsum of the ankle. Two of the three patients presented with complete rupture showing discontinuity of the tendon, thickening of the retracted portion of the tendon, and excess fluid in the tendon sheath. One patient demonstrated a partial tear showing an attenuated tendon with increased surrounding fluid. Although rupture of the tibialis anterior tendon is a rarely reported entity, MRI is a useful modality in the definitive detection and characterization of tibialis anterior tendon ruptures. (orig.)

  6. Histological Changes in the Proximal and Distal Tendon Stumps Following Transection of Achilles Tendon in the Rabbits.

    Science.gov (United States)

    Al-Qattan, Mohammad M; Mawlana, Ola Helmi; Mohammed Ahmed, Raeesa Abdel-Twab; Hawary, Khalid

    2016-05-01

    To determine tendon stump changes following unrepaired Achilles tendon lacerations in an animal model. An experimental study. King Saud University, Riyadh, Saudi Arabia, from October 2013 to January 2014. Arabbit model was developed and studied tendon retraction and histological changes in the proximal and distal stumps following transection of the Achilles tendon. Over a period of 12 weeks, retraction of the distal tendon stump was minimal (2 - 3 mm). In contrast, retraction of the proximal tendon stump peaked to reach 6 mm at 4 weeks post-injury and plateaued to reach 7 - 8 mm at the 12-week interval. Following complete transection of the Achilles tendon, tendon retraction correlated with the density of myofibroblast expression within the tendon stump. Further research is needed to investigate the pathophysiology of these findings.

  7. Novel methods for tendon investigations

    DEFF Research Database (Denmark)

    Kjær, Michael; Langberg, Henning; Bojsen-Møller, J.

    2008-01-01

    Purpose. Tendon structures have been studied for decades, but over the last decade, methodological development and renewed interest for metabolic, circulatory and tissue protein turnover in tendon tissue has resulted in a rising amount of investigations. Method. This paper will detail the various...... modern investigative techniques available to study tendons. Results. There are a variety of investigative methods available to study the correlations between mechanics and biology in tendons. Conclusion. The available methodologies not only allow for potential insight into physiological...... and pathophysiological mechanisms in tendon tissue, but also, to some extent, allow for more elaborate studies of the intact human tendon. Read More: http://informahealthcare.com/doi/full/10.1080/09638280701785403...

  8. Early integration of a bone plug in the femoral tunnel in rectangular tunnel ACL reconstruction with a bone-patellar tendon-bone graft: a prospective computed tomography analysis.

    Science.gov (United States)

    Suzuki, Tomoyuki; Shino, Konsei; Nakagawa, Shigeto; Nakata, Ken; Iwahashi, Takehiko; Kinugasa, Kazutaka; Otsubo, Hidenori; Yamashita, Toshihiko

    2011-12-01

    The purpose of this prospective study was to evaluate how early the bone plug was integrated into the rectangular femoral tunnel after anatomical ACL reconstruction using a bone-patellar tendon-bone (BTB) graft via a rectangular tunnel (RT BTB ACL-R). Twenty consecutive patients who had undergone the reconstruction procedure were evaluated by CT scans at 4 and 8 weeks postoperatively. In each scan, 30 slices for multiplanar reconstruction were collected parallel to the long axis of the parallelepiped femoral tunnel and perpendicular to the tendinous plane of the bone plug. Each slice was classified as "complete," indicating no visible gap between the plug and the tunnel wall or trabecular continuity or "incomplete," showing a visible gap. Bone plug-tunnel integration was evaluated as "excellent," "good," "fair," or "poor" for >20, 11-20, 5-10, and values at the anterior interface between the bone plug and the tunnel wall were also measured on both scans. The mean changes in CT value at 8 weeks were significantly lower than those at 4 weeks. This study shows that bone plug-femoral tunnel integration was almost complete by 8 weeks after surgery using RT BTB ACL-R.

  9. Histological Changes in the Proximal and Distal Tendon Stumps Following Transection of Achilles Tendon in the Rabbits

    International Nuclear Information System (INIS)

    Al-Qattan, M. M.; Hawary, K.; Mawlana, O. H.; Ahmed, R. A. M.

    2016-01-01

    Objective: To determine tendon stump changes following unrepaired Achilles tendon lacerations in an animal model. Study Design: An experimental study. Place and Duration of Study: King Saud University, Riyadh, Saudi Arabia, from October 2013 to January 2014. Methodology: Arabbit model was developed and studied tendon retraction and histological changes in the proximal and distal stumps following transection of the Achilles tendon. Result: Over a period of 12 weeks, retraction of the distal tendon stump was minimal (2 - 3 mm). In contrast, retraction of the proximal tendon stump peaked to reach 6 mm at 4 weeks post-injury and plateaued to reach 7 - 8 mm at the 12-week interval. Conclusion: Following complete transection of the Achilles tendon, tendon retraction correlated with the density of myofibroblast expression within the tendon stump. Further research is needed to investigate the pathophysiology of these findings. (author)

  10. Serial superficial digital flexor tendon biopsies for diagnosing and monitoring collagenase-induced tendonitis in horses

    Directory of Open Access Journals (Sweden)

    José C. de Lacerda Neto

    2013-06-01

    Full Text Available The purpose of this investigation was to demonstrate the feasibility of a biopsy technique by performing serial evaluations of tissue samples of the forelimb superficial digital flexor tendon (SDFT in healthy horses and in horses subjected to superficial digital flexor tendonitis induction. Eight adult horses were evaluated in two different phases (P, control (P1 and tendonitis-induced (P2. At P1, the horses were subjected to five SDFT biopsies of the left forelimb, with 24 hours (h of interval. Clinical and ultrasonographic (US examinations were performed immediately before the tendonitis induction, 24 and 48 h after the procedure. The biopsied tendon tissues were analyzed through histology. P2 evaluations were carried out three months later, when the same horses were subjected to tendonitis induction by injection of bacterial collagenase into the right forelimb SDFT. P2 clinical and US evaluations, and SDFT biopsies were performed before, and after injury induction at the following time intervals: after 24, 48, 72 and 96 h, and after 15, 30, 60, 90, 120 and 150 days. The biopsy technique has proven to be easy and quick to perform and yielded good tendon samples for histological evaluation. At P1 the horses did not show signs of localised inflammation, pain or lameness, neither SDFT US alterations after biopsies, showing that the biopsy procedure per se did not risk tendon integrity. Therefore, this procedure is feasible for routine tendon histological evaluations. The P2 findings demonstrate a relation between the US and histology evaluations concerning induced tendonitis evolution. However, the clinical signs of tendonitis poorly reflected the microscopic tissue condition, indicating that clinical presentation is not a reliable parameter for monitoring injury development. The presented method of biopsying SDFT tissue in horses enables the serial collection of material for histological analysis causing no clinical signs and tendon damage seen

  11. Sex Hormones and Tendon

    DEFF Research Database (Denmark)

    Hansen, Mette; Kjaer, Michael

    2016-01-01

    The risk of overuse and traumatic tendon and ligament injuries differ between women and men. Part of this gender difference in injury risk is probably explained by sex hormonal differences which are specifically distinct during the sexual maturation in the teenage years and during young adulthood....... The effects of the separate sex hormones are not fully elucidated. However, in women, the presence of estrogen in contrast to very low estrogen levels may be beneficial during regular loading of the tissue or during recovering after an injury, as estrogen can enhance tendon collagen synthesis rate. Yet...... has also been linked to a reduced responsiveness to relaxin. The present chapter will focus on sex difference in tendon injury risk, tendon morphology and tendon collagen turnover, but also on the specific effects of estrogen and androgens....

  12. One-stage metatarsal lengthening by allograft interposition: a novel approach for congenital brachymetatarsia.

    Science.gov (United States)

    Giannini, Sandro; Faldini, Cesare; Pagkrati, Stavroula; Miscione, Maria Teresa; Luciani, Deianira

    2010-07-01

    Congenital brachymetatarsia, a shortened metatarsal bone, can be corrected surgically by callus distraction or one-stage lengthening using bone graft. We asked whether one-stage metatarsal lengthening using metatarsal homologous bone graft could improve forefoot function, lead to metatarsal healing, restore metatarsal parabola, and improve cosmetic appearance. We retrospectively reviewed 29 patients (41 feet) in whom we lengthened 50 metatarsals. Surgery consisted of a transverse proximal osteotomy of the metatarsal shaft and interposition of a metatarsal homologous bone graft (average, 13 mm long) fixed with an intramedullary Kirschner wire. Minimum followup was 3 years (mean, 5 years; range, 3-11 years). Bone union was achieved in all cases. The mean preoperative American Orthopaedic Foot and Ankle Society score was 37 points (range, 28-53 points) and the mean postoperative score was 88 points (range, 74-96 points), with an average improvement of 51 points. Radiographically, the mean gain in length was 13 mm (range, 10-15 mm), and the mean percentage increase was 23%. One-stage metatarsal lengthening using interposition of metatarsal homologous bone graft to correct congenital brachymetatarsia has low morbidity for the patient, limited complications, short recovery times, and restores forefoot anatomy. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  13. Changes in Achilles tendon mechanical properties following eccentric heel drop exercise are specific to the free tendon.

    Science.gov (United States)

    Obst, S J; Newsham-West, R; Barrett, R S

    2016-04-01

    Mechanical loading of the Achilles tendon during isolated eccentric contractions could induce immediate and region-dependent changes in mechanical properties. Three-dimensional ultrasound was used to examine the immediate effect of isolated eccentric exercise on the mechanical properties of the distal (free tendon) and proximal (gastrocnemii) regions of the Achilles tendon. Participants (n = 14) underwent two testing sessions in which tendon measurements were made at rest and during a 30% and 70% isometric plantar flexion contractions immediately before and after either: (a) 3 × 15 eccentric heel drops or (b) 10-min rest. There was a significant time-by-session interaction for free tendon length and strain for all loading conditions (P tendon length and strain at all contraction intensities after eccentric exercise (P tendon for any of the measured parameters. Immediate changes in Achilles tendon mechanical properties were specific to the free tendon and consistent with changes due to mechanical creep. These findings suggest that the mechanical properties of the free tendon may be more vulnerable to change with exercise compared with the gastrocnemii aponeurosis or tendon. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Implantation of a novel biologic and hybridized tissue engineered bioimplant in large tendon defect: an in vivo investigation.

    Science.gov (United States)

    Oryan, Ahmad; Moshiri, Ali; Parizi, Abdolhamid Meimandi; Maffulli, Nicola

    2014-02-01

    Surgical reconstruction of large Achilles tendon defects is technically demanding. There is no standard method, and tissue engineering may be a valuable option. We investigated the effects of 3D collagen and collagen-polydioxanone sheath (PDS) implants on a large tendon defect model in rabbits. Ninety rabbits were divided into three groups: control, collagen, and collagen-PDS. In all groups, 2 cm of the left Achilles tendon were excised and discarded. A modified Kessler suture was applied to all injured tendons to retain the gap length. The control group received no graft, the treated groups were repaired using the collagen only or the collagen-PDS prostheses. The bioelectrical characteristics of the injured areas were measured at weekly intervals. The animals were euthanized at 60 days after the procedure. Gross, histopathological and ultrastructural morphology and biophysical characteristics of the injured and intact tendons were investigated. Another 90 pilot animals were also used to investigate the inflammatory response and mechanism of graft incorporation during tendon healing. The control tendons showed severe hyperemia and peritendinous adhesion, and the gastrocnemius muscle of the control animals showed severe atrophy and fibrosis, with a loose areolar connective tissue filling the injured area. The tendons receiving either collagen or collagen-PDS implants showed lower amounts of peritendinous adhesion, hyperemia and muscle atrophy, and a dense tendon filled the defect area. Compared to the control tendons, application of collagen and collagen-PDS implants significantly improved water uptake, water delivery, direct transitional electrical current and tissue resistance to direct transitional electrical current. Compared to the control tendons, both prostheses showed significantly increased diameter, density and alignment of the collagen fibrils and maturity of the tenoblasts at ultrastructure level. Both prostheses influenced favorably tendon healing

  15. Extremity salvage with a free musculocutaneous latissimus dorsi flap and free tendon transfer after resection of a large congenital fibro sarcoma in a 15-week-old infant. A case report.

    Science.gov (United States)

    Germann, G; Waag, K-L; Selle, B; Jester, A

    2006-01-01

    A case of complex microsurgical reconstruction of the dorsum of the foot, including tendon transfer following tumor resection, in a 15-week-old male infant is presented. After birth, a 5.5 x 4 cm large tumor was observed on the dorsum of the right foot. Biopsy showed a congenital malignant fibro sarcoma. After initial chemotherapy a radical excision of the tumor at the age of 14 weeks was followed. To cover the defect a musculocutaneous latissimus dorsi flap was taken, the cutaneous part being large enough to cover the defect. Extensor tendons were reconstructed with free tendon transplants. Amputation is usually indicated in these cases. To the best of our knowledge, microsurgical reconstruction in infants at this age with congenital malignant tumors has not yet been reported. The case shows that Plastic surgery can play an important role in pediatric oncology and should routinely be integrated into the multi-modal treatment concepts. (c) 2006 Wiley-Liss, Inc. Microsurgery, 2006.

  16. Do cells contribute to tendon and ligament biomechanics?

    Directory of Open Access Journals (Sweden)

    Niels Hammer

    Full Text Available Acellular scaffolds are increasingly used for the surgical repair of tendon injury and ligament tears. Despite this increased use, very little data exist directly comparing acellular scaffolds and their native counterparts. Such a comparison would help establish the effectiveness of the acellularization procedure of human tissues. Furthermore, such a comparison would help estimate the influence of cells in ligament and tendon stability and give insight into the effects of acellularization on collagen.Eighteen human iliotibial tract samples were obtained from nine body donors. Nine samples were acellularized with sodium dodecyl sulphate (SDS, while nine counterparts from the same donors remained in the native condition. The ends of all samples were plastinated to minimize material slippage. Their water content was adjusted to 69%, using the osmotic stress technique to exclude water content-related alterations of the mechanical properties. Uniaxial tensile testing was performed to obtain the elastic modulus, ultimate stress and maximum strain. The effectiveness of the acellularization procedure was histologically verified by means of a DNA assay.The histology samples showed a complete removal of the cells, an extensive, yet incomplete removal of the DNA content and alterations to the extracellular collagen. Tensile properties of the tract samples such as elastic modulus and ultimate stress were unaffected by acellularization with the exception of maximum strain.The data indicate that cells influence the mechanical properties of ligaments and tendons in vitro to a negligible extent. Moreover, acellularization with SDS alters material properties to a minor extent, indicating that this method provides a biomechanical match in ligament and tendon reconstruction. However, the given protocol insufficiently removes DNA. This may increase the potential for transplant rejection when acellular tract scaffolds are used in soft tissue repair. Further research

  17. Arthroscopic-Assisted Triangular Fibrocartilage Complex Reconstruction.

    Science.gov (United States)

    Chu-Kay Mak, Michael; Ho, Pak-Cheong

    2017-11-01

    Injury of the triangular fibrocartilage complex (TFCC) is a common cause of ulnar-sided wrist pain. Volar and dorsal radioulnar ligaments and their foveal insertion are the most important stabilizing components of the TFCC. In irreparable tears, anatomic reconstruction of the TFCC aims to restore normal biomechanics and stability of the distal radioulnar joint. We proposed a novel arthroscopic-assisted technique using a palmaris longus tendon graft. Arthroscopic-assisted TFCC reconstruction is a safe and effective approach with outcomes comparable to conventional open reconstruction and may result in a better range of motion from minimizing soft tissue dissection and subsequent scarring. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Experience with 32 Pelvic Fracture Urethral Defects Associated with Urethrorectal Fistulas: Transperineal Urethroplasty with Gracilis Muscle Interposition.

    Science.gov (United States)

    Guo, Hailin; Sa, Yinglong; Fu, Qiang; Jin, Chongrui; Wang, Lin

    2017-07-01

    Pelvic fracture urethral defects associated with urethrorectal fistulas are rare and difficult to repair. The aim of this study was to evaluate the efficacy of transperineal urethroplasty with gracilis muscle interposition for the repair of pelvic fracture urethral defects associated with urethrorectal fistulas. We identified 32 patients who underwent transperineal urethroplasty with gracilis muscle interposition to repair pelvic fracture urethral defects associated with urethrorectal fistulas. Patient demographics as well as preoperative, operative and postoperative data were obtained. Mean followup was 33 months (range 6 to 64). The overall success rate was 91% (29 of 32 cases). One-stage repair was successful in 17 of 18 patients (94%) using perineal anastomosis with separation of the corporeal body and in 12 of 14 (86%) using perineal anastomosis with inferior pubectomy and separation of the corporeal body. All 22 patients (100%) without a previous history of repair were successfully treated. However, only 7 of 10 patients (70%) with a previous history of failed urethroplasty and urethrorectal fistula repair were cured. Recurrent urethral strictures developed in 2 cases. One patient was treated successfully with optical internal urethrotomy and the other was treated successfully with tubed perineoscrotal flap urethroplasty. Recurrent urethrorectal fistulas associated with urethral strictures developed in an additional patient. Transperineal urethroplasty with gracilis muscle interposition is a safe and effective surgical procedure for most pelvic fracture urethral defects associated with urethrorectal fistulas. Several other factors may affect its postoperative efficiency. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. Simultaneous bilateral distal biceps tendon rupture during a preacher curl exercise: a case report.

    Science.gov (United States)

    Rokito, Andrew S; lofin, Ilya

    2008-01-01

    Complete rupture of the distal biceps tendon is a rare injury, the overwhelming majority occurring in the dominant arm of males during the fourth to sixth decades of life. Simultaneous bilateral rupture of the distal biceps tendon is an extremely rare occurrence, with only three cases reported in the literature. This unusual injury occurred in a recreational weightlifter during a preacher curl exercise. In this particular case, a 6-week delay in presentation necessitated a staged procedure in which a primary repair was feasible in one elbow, while reconstruction using allograft tissue was required in the contralateral elbow. Satisfactory results for both elbows were achieved, with return to weightlifting by one year following surgery.

  20. Osteocalcin expressing cells from tendon sheaths in mice contribute to tendon repair by activating Hedgehog signaling

    OpenAIRE

    Wang, Yi; Zhang, Xu; Huang, Huihui; Xia, Yin; Yao, YiFei; Mak, Arthur Fuk-Tat; Yung, Patrick Shu-Hang; Chan, Kai-Ming; Wang, Li; Zhang, Chenglin; Huang, Yu; Mak, Kingston King-Lun

    2017-01-01

    Both extrinsic and intrinsic tissues contribute to tendon repair, but the origin and molecular functions of extrinsic tissues in tendon repair are not fully understood. Here we show that tendon sheath cells harbor stem/progenitor cell properties and contribute to tendon repair by activating Hedgehog signaling. We found that Osteocalcin (Bglap) can be used as an adult tendon-sheath-specific marker in mice. Lineage tracing experiments show that Bglap-expressing cells in adult sheath tissues pos...

  1. Outcomes and complications following graft reconstruction for anterior sternoclavicular joint instability.

    Science.gov (United States)

    Willinger, Lukas; Schanda, Jakob; Herbst, Elmar; Imhoff, Andreas B; Martetschläger, Frank

    2016-12-01

    Publications describing tendon graft reconstruction for anterior sternoclavicular joint (SCJ) instability are rare and usually refer to small patient numbers. The aim of this study was to systematically review the literature regarding outcomes and complications following tendon graft reconstruction techniques for anterior SCJ instability. An online database was systematically searched to identify studies on graft reconstruction for anterior SCJ instability. Reported outcome scores were graded as excellent, good, fair and poor to summarize the study results. All reported complications were recorded. Five articles with a total of 80 patients met the inclusion criteria. Reported outcomes were excellent in 10 %, good in 89 % and fair in 1 %. Recurrent instability was found in 10 % of the patients, and 5 % underwent revision surgery due to persistent impairment of shoulder function related to SCJ instability or osteoarthritis. Surgical stabilization techniques for the SCJ using autologous tendon grafts have shown to be safe and reliable and make better patients' pain situation and shoulder function. However, a certain amount of impairment might persist, which needs to be discussed with patients. Severe complications were rare and revision rates were as low as 5 %. Therefore, graft reconstruction techniques should be considered for patients with chronic anterior SCJ instability after a course of failed conservative treatment. This study is valuable for clinicians in daily clinical practice when dealing with this difficult-to-treat pathology and can help surgeons to better predict the clinical outcomes and complications following SCJ graft reconstruction. It should, however, not lead to underestimation of the potential risks of the procedure. Systematic review, Level IV.

  2. Bioreactor Design for Tendon/Ligament Engineering

    OpenAIRE

    Wang, Tao; Gardiner, Bruce S.; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B.; Wang, Allan; Xu, Jiake; Smith, David W.; Lloyd, David G.; Zheng, Ming H.

    2012-01-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a s...

  3. FUNCTIONAL OUTCOME OF ACCELERATED REHABILITATION IN ARTHROSCOPIC ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION WITH BONE PATELLAR TENDON BONE GRAFT A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Hiranyakumar

    2016-03-01

    Full Text Available INTRODUCTION An ideal rehabilitation program post anterior cruciate ligament reconstruction enables an individual to return to pre injury levels at a faster rate with minimal to no risk of reinjury to the graft. Rehabilitation protocols have changed considerably over time in the past. It has become “aggressive”, meaning an intensive rehabilitation which includes greater variety of exercises and sports related training. AIM OF THE STUDY The aim of our study is to assess the outcome of accelerated rehabilitation post anterior cruciate ligament (ACL reconstruction. METHODOLOGY 106 patients were operated by a single surgeon underwent arthroscopic anterior cruciate ligament reconstruction using bone patella tendon bone graft and partial meniscectomy for associated meniscal tear. Patients were put on an accelerated rehabilitation protocol designed in our institute on first post-operative day, under the guidance of a physical therapist in consultation with the operated surgeon. Patients were followed up at 3 weeks, 6 months and 9 months, post onset of rehabilitation, patients were assessed using KT1000 Arthrometer and Lysholm knee scoring system. RESULTS Out of 106 patients, who were selected, 96(91% were males and 10(9% were females. The mean pre-operative Lysholm score was 55.09. Post operatively, while on accelerated rehabilitation program the Lysholm scores were 69.73 at 3 weeks, 89.13 at 6 months and 89.19 at 9 months. In our pre-operative evaluation mean KT 1000 arthrometer score was 10.53 and post-operative at six months was 3.49. At nine months 105 patients had excellent results whereas 1 patient had good result. CONCLUSION Accelerated rehabilitation protocol enables the patient to functionally recover faster to pre injury levels. A rehabilitation protocol for 6 months is sufficient in enabling a patient to get back to pre-injury levels. Functional outcome is the same with or without associated meniscal injuries.

  4. In vitro and in vivo effects of PDGF-BB delivery strategies on tendon healing: a review

    Directory of Open Access Journals (Sweden)

    O Evrova

    2017-07-01

    Full Text Available To promote and support tendon healing, one viable strategy is the use or administration of growth factors at the wound/rupture site. Platelet derived growth factor-BB (PDGF-BB, together with other growth factors, is secreted by platelets after injury. PDGF-BB promotes mitogenesis and angiogenesis, which could accelerate tendon healing. Therefore, in vitro studies with PDGF-BB have been performed to determine its effect on tenocytes and tenoblasts. Moreover, accurate and sophisticated drug delivery devices, aiming for a sustained release of PDGF-BB, have been developed, either by using heparin-binding and fibrin-based matrices or different electrospinning techniques. In this review, the structure and composition, as well as the healing process of tendons, are described. Part A deals with in vitro studies. They focus on the multiple effects evoked by PDGF-BB on the cellular level. Moreover, they address strategies for the sustained delivery of PDGF-BB. Part B focuses on animal models used to test different delivery strategies for PDGF-BB, in the context of tendon reconstruction. These studies showed that dosage and timing of PDGF-BB application are the most important factors for deciding which delivery device should be applied for a specific tendon laceration.

  5. Three-dimensional study of pectoralis major muscle and tendon architecture.

    Science.gov (United States)

    Fung, Lillia; Wong, Brian; Ravichandiran, Kajeandra; Agur, Anne; Rindlisbacher, Tim; Elmaraghy, Amr

    2009-05-01

    A thorough understanding of the normal structural anatomy of the pectoralis major (PM) is of paramount importance in the planning of PM tendon transfers or repairs following traumatic PM tears. However, there is little consensus regarding the complex musculotendinous architecture of the PM in the anatomic or surgical literature. The purpose of this study is to model and quantify the three-dimensional architecture of the pectoralis muscle and tendon. Eleven formalin embalmed cadaveric specimens were examined: five (2M/3F) were serially dissected, digitized, and modeled in 3D using Autodesk Maya; six (4M/2F) were dissected and photographed. The PM tendon consisted of longer anterior and shorter posterior layers that were continuous inferiorly. The muscle belly consisted of an architecturally uniform clavicular head (CH) and a segmented sternal head (SH) with 6-7 segments. The most inferior SH segment in all specimens was found to fold anteriorly forming a trough that cradled the inferior aspect of the adjacent superior segment. No twisting of either the PM muscle or tendon was noted. Within the CH, the fiber bundle lengths (FBL) were found to increase from superior to inferior, whereas the mean FBLs of SH were greatest in segments 3-5 found centrally. The mean lateral pennation angle was greater in the CH (29.4 +/- 6.9 degrees ) than in the SH (20.6 +/- 2.7 degrees ). The application of these findings could form the basis of future studies to optimize surgical planning and functional recovery of repair/reconstruction procedures.

  6. Optimization of human tendon tissue engineering: peracetic acid oxidation for enhanced reseeding of acellularized intrasynovial tendon.

    Science.gov (United States)

    Woon, Colin Y L; Pridgen, Brian C; Kraus, Armin; Bari, Sina; Pham, Hung; Chang, James

    2011-03-01

    Tissue engineering of human flexor tendons combines tendon scaffolds with recipient cells to create complete cell-tendon constructs. Allogenic acellularized human flexor tendon has been shown to be a useful natural scaffold. However, there is difficulty repopulating acellularized tendon with recipient cells, as cell penetration is restricted by a tightly woven tendon matrix. The authors evaluated peracetic acid treatment in optimizing intratendinous cell penetration. Cadaveric human flexor tendons were harvested, acellularized, and divided into experimental groups. These groups were treated with peracetic acid in varying concentrations (2%, 5%, and 10%) and for varying time periods (4 and 20 hours) to determine the optimal treatment protocol. Experimental tendons were analyzed for differences in tendon microarchitecture. Additional specimens were reseeded by incubation in a fibroblast cell suspension at 1 × 10(6) cells/ml. This group was then analyzed for reseeding efficacy. A final group underwent biomechanical studies for strength. The optimal treatment protocol comprising peracetic acid at 5% concentration for 4 hours produced increased scaffold porosity, improving cell penetration and migration. Treated scaffolds did not show reduced collagen or glycosaminoglycan content compared with controls (p = 0.37 and p = 0.65, respectively). Treated scaffolds were cytotoxic to neither attached cells nor the surrounding cell suspension. Treated scaffolds also did not show inferior ultimate tensile stress or elastic modulus compared with controls (p = 0.26 and p = 0.28, respectively). Peracetic acid treatment of acellularized tendon scaffolds increases matrix porosity, leading to greater reseeding. It may prove to be an important step in tissue engineering of human flexor tendon using natural scaffolds.

  7. Kartogenin with PRP promotes the formation of fibrocartilage zone in the tendon-bone interface.

    Science.gov (United States)

    Zhou, Yiqin; Zhang, Jianying; Yang, Jinsong; Narava, Manoj; Zhao, Guangyi; Yuan, Ting; Wu, Haishan; Zheng, Nigel; Hogan, MaCalus V; Wang, James H-C

    2017-12-01

    Treatment of tendon-bone junction injuries is a challenge because tendon-bone interface often heals poorly and the fibrocartilage zone, which reduces stress concentration, at the interface is not formed. In this study, we used a compound called kartogenin (KGN) with platelet-rich plasma (PRP) to induce the formation of fibrocartilage zone in a rat tendon graft-bone tunnel model. The experimental rats received KGN-PRP or PRP injections in the tendon graft-bone tunnel interface. The control group received saline. After 4, 8 and 12 weeks, Safranin O staining of the tendon graft-bone tunnels revealed abundant proteoglycans in the KGN-PRP group indicating the formation of cartilage-like transition zone. Immunohistochemical and immuno-fluorescence staining revealed collagen types I (Col-I) and II (Col-II) in the newly formed fibrocartilage zone. Both fibrocartilage zone formation and maturation were healing time dependent. In contrast, the PRP and saline control groups had no cartilage-like tissues and minimal Col-I and Col-II staining. Some gaps were also present in the saline control group. Finally, pull-out strength in the KGN-PRP-treated group at 8 weeks was 1.4-fold higher than the PRP-treated group and 1.6-fold higher than the saline control group. These findings indicate that KGN, with PRP as a carrier, promotes the formation of fibrocartilage zone between the tendon graft and bone interface. Thus, KGN-PRP may be used as a convenient cell-free therapy in clinics to promote fibrocartilage zone formation in rotator calf repair and anterior cruciate ligament reconstruction, thereby enhancing the mechanical strength of the tendon-bone interface and hence the clinical outcome of these procedures. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Extensor Tendon Injuries

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Extensor Tendon Injuries Email to a friend * required ...

  9. Magnetotherapy: The quest for tendon regeneration.

    Science.gov (United States)

    Pesqueira, Tamagno; Costa-Almeida, Raquel; Gomes, Manuela E

    2018-05-09

    Tendons are mechanosensitive tissues that connect and transmit the forces generated by muscles to bones by allowing the conversion of mechanical input into biochemical signals. These physical forces perform the fundamental work of preserving tendon homeostasis assuring body movements. However, overloading causes tissue injuries, which leads us to the field of tendon regeneration. Recently published reviews have broadly shown the use of biomaterials and different strategies to attain tendon regeneration. In this review, our focus is the use of magnetic fields as an alternative therapy, which has demonstrated clinical relevance in tendon medicine because of their ability to modulate cell fate. Yet the underlying cellular and molecular mechanisms still need to be elucidated. While providing a brief outlook about specific signalling pathways and intracellular messengers as framework in play by tendon cells, application of magnetic fields as a subcategory of physical forces is explored, opening up a compelling avenue to enhance tendon regeneration. We outline here useful insights on the effects of magnetic fields both at in vitro and in vivo levels, particularly on the expression of tendon genes and inflammatory cytokines, ultimately involved in tendon regeneration. Subsequently, the potential of using magnetically responsive biomaterials in tendon tissue engineering is highlighted and future directions in magnetotherapy are discussed. © 2018 Wiley Periodicals, Inc.

  10. Follow-up of volar plate interposition arthroplasty (Tupper) of the metacarpophalangeal joints in rheumatoid hands: preliminary findings

    DEFF Research Database (Denmark)

    Gøtze, J P; Jensen, Claus Hjorth

    2000-01-01

    We present the results of a three-year follow-up study of 59 interposition volar plate arthroplasties (Tupper) on metacarpophalangeal joints in 13 patients with erosive rheumatoid arthritis. The median age at the time of operation was 60 years (range 45-77). All patients reported lasting pain...

  11. Anatomical reconstruction of the fourth brachymetatarsia with one-stage iliac bone and cartilage cap grafting.

    Science.gov (United States)

    Woo, Sang Hyun; Bang, Chi Young; Ahn, Hee-Chan; Kim, Sung-Jung; Choi, Jun-Young

    2017-05-01

    We present a one-stage procedure for lengthening the fourth brachymetatarsia with autogenous iliac bone and cartilage cap grafting for the anatomical reconstruction of the metatarsophalangeal (MTP) joint METHODS: During the last 8 years, 56 feet in 41 patients with congenital brachymetatarsia of the fourth toe were corrected with a one-stage operation to reposition the articular cartilage cap to the distal part of interpositional iliac bone graft at the metatarsal epiphysis. The length of the harvested iliac bone graft was 22.9 mm on average. The mean fixation period was 58.5 days, and the mean gain in length and percentage increase was 20.9 mm and 39%, respectively. MRI showed a stable MTP joint over viable cartilage cap in 83.3% of the cases. Mean postoperative American Orthopedic Foot and Ankle Society lesser MTP-interphalangeal score was 82.0. Neither neurovascular impairment nor recurrence of brachymetatarsia occurred in the mean follow-up period of 43.6 months. All patients were satisfied with the postoperative cosmetic results. Thirteen patients (23.2%) complained of limited active dorsiflexion of the fourth toe, and extensor adhesion was released by extensor tenolysis in only one patient. In a single case of nonunion at the bone graft site, additional surgery was not necessary. Anatomical reconstruction of the fourth brachymetatarsia with one-stage interpositional iliac bone and cartilage cap grafting resulted in excellent cosmetic results and a physiologic MTP joint, providing the benefits of one-stage lengthening with a low complication rate. Therapeutic, IV. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Achilles Tendon's Tear

    OpenAIRE

    F. Shahandeh

    2008-01-01

    Introduction: The achilles and plantaris tendons to-gether makeup the posterior grouptendons of ankle. Their seldom confusion in interpreting MR images of the achilles tendon. The achilles tendon should ap-pear informally straight and black on sagital T1 weighted images and on fluid sensitive images."nCase Presentation: After a heavy sport, a 55 year-old woman cannot walk with right foot."nDiscussion: The classic achilles tendon rupture occurs with forced dorsiflexion of planted foo...

  13. Bioreactor design for tendon/ligament engineering.

    Science.gov (United States)

    Wang, Tao; Gardiner, Bruce S; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B; Wang, Allan; Xu, Jiake; Smith, David W; Lloyd, David G; Zheng, Ming H

    2013-04-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a suitable culture environment, which mimics the dynamics of the in vivo environment for tendon/ligament maturation. For clinical settings, bioreactors also have the advantages of less-contamination risk, high reproducibility of cell propagation by minimizing manual operation, and a consistent end product. In this review, we identify the key components, design preferences, and criteria that are required for the development of an ideal bioreactor for engineering tendons and ligaments.

  14. High-resolution study of the 3D collagen fibrillary matrix of Achilles tendons without tissue labelling and dehydrating.

    Science.gov (United States)

    Wu, Jian-Ping; Swift, Benjamin John; Becker, Thomas; Squelch, Andrew; Wang, Allan; Zheng, Yong-Chang; Zhao, Xuelin; Xu, Jiake; Xue, Wei; Zheng, Minghao; Lloyd, David; Kirk, Thomas Brett

    2017-06-01

    Knowledge of the collagen structure of an Achilles tendon is critical to comprehend the physiology, biomechanics, homeostasis and remodelling of the tissue. Despite intensive studies, there are still uncertainties regarding the microstructure. The majority of studies have examined the longitudinally arranged collagen fibrils as they are primarily attributed to the principal tensile strength of the tendon. Few studies have considered the structural integrity of the entire three-dimensional (3D) collagen meshwork, and how the longitudinal collagen fibrils are integrated as a strong unit in a 3D domain to provide the tendons with the essential tensile properties. Using second harmonic generation imaging, a 3D imaging technique was developed and used to study the 3D collagen matrix in the midportion of Achilles tendons without tissue labelling and dehydration. Therefore, the 3D collagen structure is presented in a condition closely representative of the in vivo status. Atomic force microscopy studies have confirmed that second harmonic generation reveals the internal collagen matrix of tendons in 3D at a fibril level. Achilles tendons primarily contain longitudinal collagen fibrils that braid spatially into a dense rope-like collagen meshwork and are encapsulated or wound tightly by the oblique collagen fibrils emanating from the epitenon region. The arrangement of the collagen fibrils provides the longitudinal fibrils with essential structural integrity and endows the tendon with the unique mechanical function for withstanding tensile stresses. A novel 3D microscopic method has been developed to examine the 3D collagen microstructure of tendons without tissue dehydrating and labelling. The study also provides new knowledge about the collagen microstructure in an Achilles tendon, which enables understanding of the function of the tissue. The knowledge may be important for applying surgical and tissue engineering techniques to tendon reconstruction. © 2017 The Authors

  15. Optimal arm posture control and tendon traction forces of a coupled tendon-driven manipulator

    International Nuclear Information System (INIS)

    Ma, Shugen

    1997-01-01

    In this study, the optimum arm posture of a coupled tendon-driven multijoint manipulator arm (or CT Arm) at maximum payload output was derived and the corresponding tendon traction forces were also analyzed, during management of a heavy payload by the manipulator in a gravity environment. The CT Arm is special tendon traction transmission mechanism in which a pair of tendons used to drive a joint is pulled from base actuators via pulleys mounted on the base-side joints. This mechanism enables optimal utilization of the coupled drive function of tendon traction forces and thus enables the lightweight manipulator to exhibit large payload capability. The properties of the CT Arm mechanism are elucidated by the proposed optimal posture control scheme. Computer simulation was also executed to verify the validity of the proposed control scheme. (author)

  16. Soft tissue reinforcement interposition flaps in hypospadias repair

    Directory of Open Access Journals (Sweden)

    Singh R

    2007-01-01

    Full Text Available Purpose: To discuss the role and mechanism of action of soft tissue reinforcement interposition flaps (STRIFs in hypospadias repairs (reinforced hypospadiac urethroplasties. Materials and Methods: Between 2000-2005, 120 consecutive hypospadiacs (distal 85, mid 20, proximal 15, who underwent primary reinforced urethroplasties employing different types of STRIFs, were retrospectively analyzed. The STRIFs were highly vascular soft tissue pedicled flaps (devoid of epithelium interposed between neo-urethras and the covering skin to reinforce the neo-urethras against fistula formation. The STRIFs were harvested, without much donor site deformity, from: preputial skin, penile skin and scrotal skin by de-epithelialization. Those from Buck′s fascia, corpus spongiosum and tunica vaginalis are STRIFs without epithelium anyway, therefore do not need de-epithelialization. Redo urethroplasties and micropenises were not included. Seven patients were excluded because they had incomplete follow-up. The remaining 113 (distal 84, mid 17, proximal 12 were followed up for nine to 40 months for number, size, location, spontaneous closure and persistence of urethro-cutaneous fistula (UCF, and other complications with regard to the severity of hypospadias, method of neourethral re-construction, types of STRIFs employed and skin cover used. A total of 158 STRIFs and 124 skin covers were used in 113 hypospadiac urethroplasties. Results: The first surgery was curative in 74 (65% of 113 patients. In the remaining 39 (35%, various complications included 12 urethro-cutaneous fistulas (UCFs, 10 urethral strictures, six cases each of penile torsion and meatal stenosis and five cases each of superficial necrosis and poor cosmesis. Of these 39 patients, 25 (64% recovered with conservative treatment and 14 (36% required re-operation, i.e. UCFs and strictures in four cases each and penile torsion, meatal stenosis and dog-ears in two cases each. All the 12 UCFs were single

  17. Total Ossicular Replacement Prosthesis: A New Fat Interposition Technique

    Directory of Open Access Journals (Sweden)

    Issam Saliba

    2018-01-01

    Full Text Available Objective: To compare audiometric results between the standard total ossicular replacement prosthesis (TORP-S and a new fat interposition total ossicular replacement prosthesis (TORP-F in pediatric and adult patients and to assess the complication and the undesirable outcome. Study design: This is a retrospective study. Methods: This study included 104 patients who had undergone titanium implants with TORP-F and 54 patients who had undergone the procedure with TORP-S between 2008 and 2013 in our tertiary care centers. The new technique consists of interposing a fat graft between the 4 legs of the universal titanium prosthesis (Medtronic Xomed Inc, Jacksonville, FL, USA to provide a more stable TORP in the ovale window niche. Normally, this prosthesis is designed to fit on the stapes’ head as a partial ossicular replacement prosthesis. Results: The postoperative air-bone gap less than 25 dB for the combined cohort was 69.2% and 41.7% for the TORP-F and the TORP-S groups, respectively. The mean follow-up was 17 months postoperatively. By stratifying data, the pediatric cohort shows 56.5% in the TORP-F group (n = 52 compared with 40% in the TORP-S group (n = 29. However, the adult cohort shows 79.3% in the TORP-F group (n = 52 compared with 43.75% in the TORP-S group (n = 25. These improvements in hearing were statistically significant. There were no statistically significant differences in the speech discrimination scores. The only undesirable outcome that was statistically different between the 2 groups was the prosthesis displacement: 7% in the TORP-F group compared with 19% in the TORP-S group ( P  = .03. Conclusions: The interposition of a fat graft between the legs of the titanium implants (TORP-F provides superior hearing results compared with a standard procedure (TORP-S in pediatric and adult populations because of its better stability in the oval window niche.

  18. Total Ossicular Replacement Prosthesis: A New Fat Interposition Technique.

    Science.gov (United States)

    Saliba, Issam; Sabbah, Valérie; Poirier, Jackie Bibeau

    2018-01-01

    To compare audiometric results between the standard total ossicular replacement prosthesis (TORP-S) and a new fat interposition total ossicular replacement prosthesis (TORP-F) in pediatric and adult patients and to assess the complication and the undesirable outcome. This is a retrospective study. This study included 104 patients who had undergone titanium implants with TORP-F and 54 patients who had undergone the procedure with TORP-S between 2008 and 2013 in our tertiary care centers. The new technique consists of interposing a fat graft between the 4 legs of the universal titanium prosthesis (Medtronic Xomed Inc, Jacksonville, FL, USA) to provide a more stable TORP in the ovale window niche. Normally, this prosthesis is designed to fit on the stapes' head as a partial ossicular replacement prosthesis. The postoperative air-bone gap less than 25 dB for the combined cohort was 69.2% and 41.7% for the TORP-F and the TORP-S groups, respectively. The mean follow-up was 17 months postoperatively. By stratifying data, the pediatric cohort shows 56.5% in the TORP-F group (n = 52) compared with 40% in the TORP-S group (n = 29). However, the adult cohort shows 79.3% in the TORP-F group (n = 52) compared with 43.75% in the TORP-S group (n = 25). These improvements in hearing were statistically significant. There were no statistically significant differences in the speech discrimination scores. The only undesirable outcome that was statistically different between the 2 groups was the prosthesis displacement: 7% in the TORP-F group compared with 19% in the TORP-S group ( P  = .03). The interposition of a fat graft between the legs of the titanium implants (TORP-F) provides superior hearing results compared with a standard procedure (TORP-S) in pediatric and adult populations because of its better stability in the oval window niche.

  19. High-field MR imaging of the tendons

    International Nuclear Information System (INIS)

    Beltran, J.; Burk, J.M.; Herman, L.J.; Mosure, J.C.

    1987-01-01

    MR imaging was used to investigate normal anatomy and pathologic conditions of the tendons. Tendons of experimental animals, cadaver joints, normal volunteers, and patients with suspected tendon pathology were studied. Tendon anatomy is easily identified because of the hypointensity of the tendons contrasting with the hyperintendensity of the surrounding fat. Pathologic conditions including posttraumatic and postsurgical tendon rupture, peritendinous scarring, tendinitis, and tenosynovitis are well seen with MR imaging. A detailed study of normal and abnormal tendon anatomy of the finger, wrist, shoulder, knee, and ankle is displayed, including MR images, gross specimens, and line drawings

  20. Clinical aspects of tendon healing

    NARCIS (Netherlands)

    J.C.H.M. van der Meulen (Jacques)

    1974-01-01

    textabstractWe know that healing of a tendon wound takes place by an invasion of fibreblasts from the surrounding tissues; the tendon itself has no intrinsic healing capacity. lt was Potenza (1962) who proved that a traumatic suture of the tendons within their sheath is followed by disintegration of

  1. MRI of anterior cruciate ligament repair with patellar and hamstring tendon autografts

    International Nuclear Information System (INIS)

    Jansson, K.A.; Karjalainen, P.T.; Harilainen, A.; Sandelin, J.; Tallroth, K.; Soila, K.; Aronen, H.J.

    2001-01-01

    Objective. Several MRI sequences were used to evaluate the 2-year postoperative appearance of asymptomatic knee with a torn anterior cruciate ligament (ACL) reconstructed with bone-patellar tendon-bone (BTB) and semitendinosus and gracilis (STG) tendon autografts.Design and patients. Two groups with successful repair of ACL tear with BTB (n=10) or STG (n=10) autografts were imaged at 1.5 T with sagittal and oblique coronal proton density-, T2-weighted and sagittal STIR sequences and plain and contrast-enhanced oblique coronal T1-weighted sequences. The appearance of the graft and periligamentous tissues was evaluated.Results. In all 20 cases, the ACL graft showed homogeneous, low signal intensity with periligamentous streaks of intermediate signal intensity on T2-weighted images. In 10 cases, localised areas of intermediate signal intensity were seen in the intra-articular segment of the graft on proton density- and T1-weighted images. The graft itself did not show enhancement in either of the two groups, but mild to moderate periligamentous enhancement was detected in 10 cases.Conclusion. The MRI appearance of ACL autograft is variable on proton density- and T1-weighted images. Periligamentous tissue showing contrast enhancement is a typical MRI finding after clinically successful ACL reconstruction. (orig.)

  2. Synovial Mesenchymal Stem Cells Promote Meniscus Regeneration Augmented by an Autologous Achilles Tendon Graft in a Rat Partial Meniscus Defect Model

    Science.gov (United States)

    Ozeki, Nobutake; Muneta, Takeshi; Matsuta, Seiya; Koga, Hideyuki; Nakagawa, Yusuke; Mizuno, Mitsuru; Tsuji, Kunikazu; Mabuchi, Yo; Akazawa, Chihiro; Kobayashi, Eiji; Saito, Tomoyuki; Sekiya, Ichiro

    2015-01-01

    Although meniscus defects and degeneration are strongly correlated with the later development of osteoarthritis, the promise of regenerative medicine strategies is to prevent and/or delay the disease's progression. Meniscal reconstruction has been shown in animal models with tendon grafting and transplantation of mesenchymal stem cells (MSCs); however, these procedures have not shown the same efficacy in clinical studies. Here, our aim was to investigate the ability of tendon grafts pretreated with exogenous synovial-derived MSCs to prevent cartilage degeneration in a rat partial meniscus defect model. We removed the anterior half of the medial meniscus and grafted autologous Achilles tendons with or without a 10-minute pretreatment of the tendon with synovial MSCs. The meniscus and surrounding cartilage were evaluated at 2, 4, and 8 weeks (n = 5). Tendon grafts increased meniscus size irrespective of synovial MSCs. Histological scores for regenerated menisci were better in the tendon + MSC group than in the other two groups at 4 and 8 weeks. Both macroscopic and histological scores for articular cartilage were significantly better in the tendon + MSC group at 8 weeks. Implanted synovial MSCs survived around the grafted tendon and native meniscus integration site by cell tracking assays with luciferase+, LacZ+, DiI+, and/or GFP+ synovial MSCs and/or GFP+ tendons. Flow cytometric analysis showed that transplanted synovial MSCs retained their MSC properties at 7 days and host synovial tissue also contained cells with MSC characteristics. Synovial MSCs promoted meniscus regeneration augmented by autologous Achilles tendon grafts and prevented cartilage degeneration in rats. Stem Cells 2015;33:1927–1938 PMID:25993981

  3. A Rare Case of Simultaneous Acute Bilateral Quadriceps Tendon Rupture and Unilateral Achilles Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Wei Yee Leong

    2013-07-01

    Full Text Available Introduction: There have been multiple reported cases of bilateral quadriceps tendon ruptures (QTR in the literature. These injuries frequently associated with delayed diagnosis, which results in delayed surgical treatment. In very unusual cases, bilateral QTRs can be associated with other simultaneous tendon ruptures. Case Report: We present a rare case of bilateral QTR with a simultaneous Achilles Tendon Rupture involving a 31 years old Caucasian man who is a semi-professional body builder taking anabolic steroids. To date bilateral QTR with additional TA rupture has only been reported once in the literature and to our knowledge this is the first reported case of bilateral QTR and simultaneous TA rupture in a young, fit and healthy individual. Conclusion: The diagnosis of bilateral QTR alone can sometimes be challenging and the possibility of even further tendon injuries should be carefully assessed. A delay in diagnosis could result in delay in treatment and potentially worse outcome for the patient. Keywords: Quadriceps tendon rupture; Achilles tendon rupture; Bilateral.

  4. Achilles tendon healing

    International Nuclear Information System (INIS)

    Dillon, E.H.; Pope, C.F.; Barber, V.; Jokl, P.; Lynch, K.

    1990-01-01

    This paper reports on symptomatic Achilles tendon abnormalities (rupture, tendinitis) evaluated with MR imaging during the healing phase after either surgical or conservative treatment. A total of 21 patients were studied. Fifteen of 21 underwent surgery (13 tendon ruptures) and six were managed conservatively (one rupture). MR studies were obtained before treatment in 11, at 3 months in eight, at 6 months in seven, and at 12 months in 12. The 1.5-T spin-echo and gradient-echo images were correlated with clinical results, planter reflex response times, and calf force measurements. Sequential T2 times were obtained from representative levels in the tendons

  5. The Effect of Phospholipids (Surfactant on Adhesion and Biomechanical Properties of Tendon: A Rat Achilles Tendon Repair Model

    Directory of Open Access Journals (Sweden)

    T. Kursat Dabak

    2015-01-01

    Full Text Available Adhesion of the tendon is a major challenge for the orthopedic surgeon during tendon repair. Manipulation of biological environment is one of the concepts to prevent adhesion. Lots of biochemicals have been studied for this purpose. We aimed to determine the effect of phospholipids on adhesion and biomechanical properties of tendon in an animal tendon repair model. Seventy-two Wistar rats were divided into 4 groups. Achilles tendons of rats were cut and repaired. Phospholipids were applied at two different dosages. Tendon adhesion was determined histopathologically and biomechanical test was performed. At macroscopic evaluation of adhesion, there are statistically significant differences between multiple-dose phospholipid injection group and Control group and also hyaluronic acid group and Control group (p0.008. Ultimate strength was highest at hyaluronic acid injection group and lowest at multiple-dose phospholipid injection group. Single-dose phospholipids (surfactant application may have a beneficial effect on the tendon adhesion. Although multiple applications of phospholipids seem the most effective regime to reduce the tendon adhesion among groups, it deteriorated the biomechanical properties of tendon.

  6. MRI findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Zhang Xuezhe

    2009-01-01

    Objective: To evaluate the MRI findings of achilles tendon rupture. Methods: The MRI data of 7 patients with achilles tendon rupture were retrospectively analysed. All 7 patients were male with the age ranging from 34 to 71 years. Routine MR scanning was performed in axial and sagittal planes, including T 1 WI, T 2 WI and a fat suppression MRI (SPIR). Results: Among 7 patients, complete achilles tendon rupture was seen in 6 cases, partial achilles tendon rupture 1 case. The site of tendon disruption were 2.6-11.0 cm( mean 5.4 cm) proximal to the insertion in the calcaneus. The MRI findings of a partial or complete rupture of the achilles tendon included enlarged and thickened achilles tendon (7 cases), wavy lax achilles tendon (2 cases), discontinuity of some or all of its fibers and intratendinous regions of increased signal intensity (7 cases). In the cases of complete tendon rupture, the size of the tendinous gap varied from 3.0-8.0 mm, which was filled with blood and appeared as edema of increase signal intensity on T 2 WI and SPIR. In all 7 patients, MR scanning showed medium signal intensity (7 cases) on T 1 WI, or medium signal intensity (1 cases), medium-high signal intensity (3 cases ), high signal intensity (3 cases) on T 2 WI, and medium-high signal intensity (2 cases), high signal intensity (5 cases) on fat suppression MRI. The preachilles fat pad showed obscure in 6 cases of complete achilles tendon rupture. Conclusion: MRI is an excellent method for revealing achilles tendon rupture and confirming the diagnosis. (authors)

  7. Can PRP effectively treat injured tendons?

    Science.gov (United States)

    Wang, James H-C

    2014-01-01

    PRP is widely used to treat tendon and other tissue injuries in orthopaedics and sports medicine; however, the efficacy of PRP treatment on injured tendons is highly controversial. In this commentary, I reason that there are many PRP- and patient-related factors that influence the outcomes of PRP treatment on injured tendons. Therefore, more basic science studies are needed to understand the mechanism of PRP on injured tendons. Finally, I suggest that better understanding of the PRP action mechanism will lead to better use of PRP for the effective treatment of tendon injuries in clinics.

  8. Bioresorbable pins and interference screws for fixation of hamstring tendon grafts in anterior cruciate ligament reconstruction surgery: a randomized controlled trial.

    Science.gov (United States)

    Stengel, Dirk; Casper, Dirk; Bauwens, Kai; Ekkernkamp, Axel; Wich, Michael

    2009-09-01

    Biodegradable cross-pins have been shown to provide higher failure loads than do screws for fixation of hamstring tendons under laboratory conditions. To compare the clinical results of biodegradable pins (RigidFix) and interference screws (BioCryl) for fixation of hamstring grafts in arthroscopically assisted anterior cruciate ligament reconstruction. Study Design Randomized controlled trial; Level of evidence, 1. To test the hypothesis of a difference of 1.0 +/- 1.2 mm in anterior knee laxity between the two fixation options, 54 patients were randomly assigned to groups via a block randomization scheme and sealed envelopes. All patients underwent standardized hamstring graft reconstruction and had similar postoperative aftercare by an accelerated rehabilitation protocol. Measures assessed at baseline and after 1 and 2 years of follow-up included (1) the side-to-side difference in anterior laxity (KT-1000 arthrometer), (2) Short Form 36 physical and mental component scores, and (3) the International Knee Documentation Committee form scores. After 1 and 2 years, 26 and 21 patients in the BioCryl group and 28 and 24 patients in the RigidFix group were available for follow-up examination. No significant difference was noted in instrumented anterior translation between BioCryl and RigidFix fixation: 1 year, 0.11 (95% CI, -0.60 to 0.82; P = .7537); 2 years, 0.33 (95% CI, -0.43 to 1.08 mm; P = .3849). Also, there were no significant differences in the mean physical and mental component scores and International Knee Documentation Committee form scores and in overall complication and surgical revision rates. A pin dislocation was classified as the sole procedure-specific serious adverse event. Bioresorbable pins do not provide better clinical results than do resorbable interference screws for hamstring graft fixation in anterior cruciate ligament reconstruction surgery.

  9. Development of hybrid polymer scaffolds for potential applications in ligament and tendon tissue engineering

    Energy Technology Data Exchange (ETDEWEB)

    Sahoo, Sambit [Tissue Repair Lab, Division of Bioengineering, National University of Singapore, Singapore 117574 (Singapore); Cho-Hong, James Goh [Tissue Repair Lab, Division of Bioengineering, National University of Singapore, Singapore 117574 (Singapore); Siew-Lok, Toh [Tissue Repair Lab, Division of Bioengineering, National University of Singapore, Singapore 117574 (Singapore)

    2007-09-15

    Fibre-based scaffolds have been widely used for tendon and ligament tissue engineering. Knitted scaffolds have been proved to favour collagenous matrix deposition which is crucial for tendon/ligament reconstruction. However, such scaffolds have the limitation of being dependent on a gel system for cell seeding, which is unstable in a dynamic environment such as the knee joint. This study developed three types of hybrid scaffolds, based on knitted biodegradable polyester scaffolds, aiming to improve mechanical properties and cell attachment and proliferation on the scaffolds. The hybrid scaffolds were created by coating the knitted scaffolds with a thin film of poly ({epsilon}-caprolactone) (group I), poly (D, L-lactide-co-glycolide) nanofibres (group II) and type 1 collagen (group III). Woven scaffolds were also fabricated and compared with the various hybrid scaffolds in terms of their mechanical properties during in vitro degradation and cell attachment and growth. This study demonstrated that the coating techniques could modulate the mechanical properties and facilitate cell attachment and proliferation in the hybrid scaffold, which could be applied with promise in tissue engineering of tendons/ligaments.

  10. Development of hybrid polymer scaffolds for potential applications in ligament and tendon tissue engineering

    International Nuclear Information System (INIS)

    Sahoo, Sambit; Cho-Hong, James Goh; Siew-Lok, Toh

    2007-01-01

    Fibre-based scaffolds have been widely used for tendon and ligament tissue engineering. Knitted scaffolds have been proved to favour collagenous matrix deposition which is crucial for tendon/ligament reconstruction. However, such scaffolds have the limitation of being dependent on a gel system for cell seeding, which is unstable in a dynamic environment such as the knee joint. This study developed three types of hybrid scaffolds, based on knitted biodegradable polyester scaffolds, aiming to improve mechanical properties and cell attachment and proliferation on the scaffolds. The hybrid scaffolds were created by coating the knitted scaffolds with a thin film of poly (ε-caprolactone) (group I), poly (D, L-lactide-co-glycolide) nanofibres (group II) and type 1 collagen (group III). Woven scaffolds were also fabricated and compared with the various hybrid scaffolds in terms of their mechanical properties during in vitro degradation and cell attachment and growth. This study demonstrated that the coating techniques could modulate the mechanical properties and facilitate cell attachment and proliferation in the hybrid scaffold, which could be applied with promise in tissue engineering of tendons/ligaments

  11. Measuring Regional Changes in Damaged Tendon

    Science.gov (United States)

    Frisch, Catherine Kayt Vincent

    Mechanical properties of tendon predict tendon health and function, but measuring these properties in vivo is difficult. An ultrasound-based (US) analysis technique called acoustoelastography (AE) uses load-dependent changes in the reflected US signal to estimate tissue stiffness non-invasively. This thesis explores whether AE can provide information about stiffness alteration resulting from tendon tears both ex vivo and in vivo. An ex vivo ovine infraspinatus tendon model suggests that the relative load transmitted by the different tendon layers transmit different fractions of the load and that ultrasound echo intensity change during cyclic loading decreases, becoming less consistent once the tendon is torn. An in vivo human tibialis anterior tendon model using electrically stimulated twitch contractions investigated the feasibility of measuring the effect in vivo. Four of the five subjects showed the expected change and that the muscle contraction times calculated using the average grayscale echo intensity change compared favorably with the times calculated based on the force data. Finally an AE pilot study with patients who had rotator cuff tendon tears found that controlling the applied load and the US view of the system will be crucial to a successful in vivo study.

  12. Tissue engineering approaches to develop decellularized tendon matrices functionalized with progenitor cells cultured under undifferentiated and tenogenic conditions

    Directory of Open Access Journals (Sweden)

    Daniele D’Arrigo

    2017-11-01

    Full Text Available Tendon ruptures and retractions with an extensive tissue loss represent a major clinical problem and a great challenge in surgical reconstruction. Traditional approaches consist in autologous or allogeneic grafts, which still have some drawbacks. Hence, tissue engineering strategies aimed at developing functionalized tendon grafts. In this context, the use of xenogeneic tissues represents a promising perspective to obtain decellularized tendon grafts. This study is focused on the identification of suitable culture conditions for the generation of reseeded and functional decellularized constructs to be used as tendon grafts. Equine superficial digital flexor tendons were decellularized, reseeded with mesenchymal stem cells (MSCs from bone marrow and statically cultured in two different culture media to maintain undifferentiated cells (U-MSCs or to induce a terminal tenogenic differentiation (T-MSCs for 24 hours, 7 and 14 days. Cell viability, proliferation, morphology as well as matrix deposition and type I and III collagen production were assessed by means of histological, immunohistochemical and semi-quantitative analyses. Results showed that cell viability was not affected by any culture conditions and active proliferation was maintained 14 days after reseeding. However, seeded MSCs were not able to penetrate within the dense matrix of the decellularized tendons. Nevertheless, U-MSCs synthesized a greater amount of extracellular matrix rich in type I collagen compared to T-MSCs. In spite of the inability to deeply colonize the decellularized matrix in vitro, reseeding tendon matrices with U-MSCs could represent a suitable method for the functionalization of biological constructs, considering also any potential chemoattractant capability of the newly deposed extracellular matrix to recruit resident cells. This bioengineering approach can be exploited to produce functionalized tendon constructs for the substitution of large tendon defects.

  13. Tendon sheath fibroma in the thigh.

    Science.gov (United States)

    Moretti, Vincent M; Ashana, Adedayo O; de la Cruz, Michael; Lackman, Richard D

    2012-04-01

    Tendon sheath fibromas are rare, benign soft tissue tumors that are predominantly found in the fingers, hands, and wrists of young adult men. This article describes a tendon sheath fibroma that developed in the thigh of a 70-year-old man, the only known tendon sheath fibroma to form in this location. Similar to tendon sheath fibromas that develop elsewhere, our patient's lesion presented as a painless, slow-growing soft tissue nodule. Physical examination revealed a firm, nontender mass with no other associated signs or symptoms. Although the imaging appearance of tendon sheath fibromas varies, our patient's lesion appeared dark on T1- and bright on T2-weighted magnetic resonance imaging. It was well marginated and enhanced with contrast.Histologically, tendon sheath fibromas are composed of dense fibrocollagenous stromas with scattered spindle-shaped fibroblasts and narrow slit-like vascular spaces. Most tendon sheath fibromas can be successfully removed by marginal excision, although 24% of lesions recur. No lesions have metastasized. Our patient's tendon sheath fibroma was removed by marginal excision, and the patient remained disease free 35 months postoperatively. Despite its rarity, tendon sheath fibroma should be included in the differential diagnosis of a thigh mass on physical examination or imaging, especially if it is painless, nontender, benign appearing, and present in men. Copyright 2012, SLACK Incorporated.

  14. The effects of low-intensity pulsed ultrasound on tendon-bone healing in a transosseous-equivalent sheep rotator cuff model.

    Science.gov (United States)

    Lovric, Vedran; Ledger, Michael; Goldberg, Jerome; Harper, Wade; Bertollo, Nicky; Pelletier, Matthew H; Oliver, Rema A; Yu, Yan; Walsh, William R

    2013-02-01

    The purpose of this study was to examine the effects Low-intensity Pulsed Ultrasound has on initial tendon-bone healing in a clinically relevant extra-articular transosseous-equivalent ovine rotator cuff model. Eight skeletally mature wethers, randomly allocated to either control group (n = 4) or treatment group (n = 4), underwent rotator cuff surgery following injury to the infraspinatus tendon. All animals were killed 28 days post surgery to allow examination of early effects of Low-intensity Pulsed Ultrasound treatment. General improvement in histological appearance of tendon-bone integration was noted in the treatment group. Newly formed woven bone with increased osteoblast activity along the bone surface was evident. A continuum was observed between the tendon and bone in an interdigitated fashion with Sharpey's fibres noted in the treatment group. Low-intensity Pulsed Ultrasound treatment also increased bone mineral density at the tendon-bone interface (p < 0.01), while immunohistochemistry results revealed an increase in the protein expression patterns of VEGF (p = 0.038), RUNX2 (p = 0.02) and Smad4 (p = 0.05). The results of this study indicate that Low-intensity Pulsed Ultrasound may aid in the initial phase of tendon-bone healing process in patients who have undergone rotator cuff repair. This treatment may also be beneficial following other types of reconstructive surgeries involving the tendon-bone interface.

  15. Quadriceps Tendon Rupture and Contralateral Patella Tendon Avulsion Post Primary Bilateral Total Knee Arthroplasty: A Case Report

    Directory of Open Access Journals (Sweden)

    Gaurav Sharma

    2016-07-01

    Full Text Available Background: Extensor mechanism failure secondary to knee replacement could be due to tibial tubercle avulsion, Patellar tendon rupture, patellar fracture or quadriceps tendon rupture. An incidence of Patella tendon rupture of 0.17% and Quadriceps tendon rupture of around 0.1% has been reported after Total knee arthroplasty. These are considered a devastating complication that substantially affects the clinical results and are challenging situations to treat with surgery being the mainstay of the treatment. Case Description: We report here an interesting case of a patellar tendon rupture of one knee and Quadriceps tendon rupture of the contralateral knee following simultaneous bilateral knee replacement in a case of inflammatory arthritis patient. End to end repair for Quadriceps tear and augmentation with Autologous Hamstring tendon graft was done for Patella tendon rupture. OUTCOME: Patient was followed up for a period of 1 year and there was no Extension lag with a flexion of 100 degrees in both the knees. DISCUSSION: The key learning points and important aspects of diagnosing these injuries early and the management techniques are described in this unique case of bilateral extensor mechanism disruption following knee replacements.

  16. Role of tissue-engineered artificial tendon in healing of a large Achilles tendon defect model in rabbits.

    Science.gov (United States)

    Moshiri, Ali; Oryan, Ahmad; Meimandi-Parizi, Abdolhamid

    2013-09-01

    Treatment of large Achilles tendon defects is technically demanding. Tissue engineering is an option. We constructed a collagen-based artificial tendon, covered it with a polydioxanon (PDS) sheath, and studied the role of this bioimplant on experimental tendon healing in vivo. A 2-cm tendon gap was created in the left Achilles tendon of rabbits (n = 120). The animals were randomly divided into 3 groups: control (no implant), treated with tridimensional-collagen, and treated with tridimensional-collagen-bidimensional-PDS implants. Each group was divided into 2 subgroups of 60 and 120 days postinjury (DPI). Another 50 pilot animals were used to study the host-implant interaction. Physical activity of the animals was scored and ultrasonographic and bioelectrical characteristics of the injured tendons were investigated weekly. After euthanasia, macro, micro, and nano morphologies and biophysical and biomechanical characteristics of the healing tendons were studied. Treatment improved function of the animals, time dependently. At 60 and 120 DPI, the treated tendons showed significantly higher maximum load, yield, stiffness, stress, and modulus of elasticity compared with controls. The collagen implant induced inflammation and absorbed the migrating fibroblasts in the defect area. By its unique architecture, it aligned the fibroblasts and guided their proliferation and collagen deposition along the stress line of the tendon and resulted in improved collagen density, micro-amp, micro-ohm, water uptake, and delivery of the regenerated tissue. The PDS-sheath covering amplified these characteristics. The implants were gradually absorbed and replaced by a new tendon. Minimum amounts of peritendinous adhesion, muscle atrophy, and fibrosis were observed in the treated groups. Some remnants of the implants were preserved and accepted as a part of the new tendon. The implants were cytocompatible, biocompatible, biodegradable, and effective in tendon healing and regeneration. This

  17. Microstructural stress relaxation mechanics in functionally different tendons.

    Science.gov (United States)

    Screen, H R C; Toorani, S; Shelton, J C

    2013-01-01

    Tendons experience widely varying loading conditions in vivo. They may be categorised by their function as either positional tendons, which are used for intricate movements and experience lower stress, or as energy storage tendons which act as highly stressed springs during locomotion. Structural and compositional differences between tendons are thought to enable an optimisation of their properties to suit their functional environment. However, little is known about structure-function relationships in tendon. This study adopts porcine flexor and extensor tendon fascicles as examples of high stress and low stress tendons, comparing their mechanical behaviour at the micro-level in order to understand their stress relaxation response. Stress-relaxation was shown to occur predominantly through sliding between collagen fibres. However, in the more highly stressed flexor tendon fascicles, more fibre reorganisation was evident when the tissue was exposed to low strains. By contrast, the low load extensor tendon fascicles appears to have less capacity for fibre reorganisation or shearing than the energy storage tendon, relying more heavily on fibril level relaxation. The extensor fascicles were also unable to sustain loads without rapid and complete stress relaxation. These findings highlight the need to optimise tendon repair solutions for specific tendons, and match tendon properties when using grafts in tendon repairs. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. Magnetic resonance evaluation of anterior cruciate ligament repair using the patellar tendon double bone block technique

    International Nuclear Information System (INIS)

    Autz, G.; Singson, R.D.; Goodwin, C.

    1991-01-01

    The magnetic resonance (MR) appearance of the anterior cruciate ligament reconstruction was determined in 20 clinically stable and 2 clinically unstable knees for a total of 22 examinations. All patients studied had undergone knee reconstruction using the patellar tendon as graft material. The reconstructed anterior cruciate ligament varies in appearance. It appeared as a thick, well-defined, low signal band on T1- and T2-weighted sagittal and coronal images in 14 of 22 examinations. The remaining 8 knees showed a graft having one or more thin and attenuated, low signal intensity bands in the sagittal and/or coronal plane. Arthroscopy confirmed an intact but lax graft in the clinically unstable knees. (orig.)

  19. Magnetic resonance evaluation of anterior cruciate ligament repair using the patellar tendon double bone block technique

    Energy Technology Data Exchange (ETDEWEB)

    Autz, G.; Singson, R.D. (St. Luke' s Roosevelt Hospital Center, New York, NY (United States). Dept. of Radiology); Goodwin, C. (St. Luke' s Roosevelt Hospital Center, New York, NY (United States). Dept. of Orthopedics)

    1991-11-01

    The magnetic resonance (MR) appearance of the anterior cruciate ligament reconstruction was determined in 20 clinically stable and 2 clinically unstable knees for a total of 22 examinations. All patients studied had undergone knee reconstruction using the patellar tendon as graft material. The reconstructed anterior cruciate ligament varies in appearance. It appeared as a thick, well-defined, low signal band on T1- and T2-weighted sagittal and coronal images in 14 of 22 examinations. The remaining 8 knees showed a graft having one or more thin and attenuated, low signal intensity bands in the sagittal and/or coronal plane. Arthroscopy confirmed an intact but lax graft in the clinically unstable knees. (orig.).

  20. The roentgenographic findings of achilles tendon rupture

    Energy Technology Data Exchange (ETDEWEB)

    Seouk, Kang Hyo; Keun, Rho Yong [Shilla General Hospital, Seoul (Korea, Republic of)

    1999-03-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture.

  1. The roentgenographic findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Seouk, Kang Hyo; Keun, Rho Yong

    1999-01-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture

  2. Tendon Force Transmission at the Nanoscale

    DEFF Research Database (Denmark)

    Svensson, René

    2013-01-01

    of connective tissue function that are poorly understood. One such aspect is the microscopic mechanisms of force transmission through tendons over macroscopic distances. Force transmission is at the heart of tendon function, but the large range of scales in the hierarchical structure of tendons has made...... it difficult to tackle. The tendon hierarchy ranges from molecules (2 nm) over fibrils (200 nm), fibers (2 μm) and fascicles (200 μm) to tendons (10 mm), and to derive the mechanisms of force transmission it is necessary to know the mechanical behavior at each hierarchical level. The aim of the present work...... was to elucidate the mechanisms of force transmission in tendons primarily by investigating the mechanical behavior at the hierarchical level of collagen fibrils. To do so we have developed an atomic force microscopy (AFM) method for tensile testing of native collagen fibrils. The thesis contains five papers...

  3. Orthotopic Transplantation of Achilles Tendon Allograft in Rats: With or without Incorporation of Autologous Mesenchymal Stem Cells.

    Science.gov (United States)

    Aynardi, Michael; Zahoor, Talal; Mitchell, Reed; Loube, Jeffrey; Feltham, Tyler; Manandhar, Lumanti; Paudel, Sharada; Schon, Lew; Zhang, Zijun

    2018-02-01

    The biology and function of orthotopic transplantation of Achilles tendon allograft are unknown. Particularly, the revitalization of Achilles allograft is a clinical concern. Achilles allografts were harvested from donor rats and stored at -80 °C. Subcutaneous adipose tissue was harvested from the would-be allograft recipient rats for isolation of mesenchymal stem cells (MSCs). MSCs were cultured with growth differentiation factor-5 (GDF-5) and applied onto Achilles allografts on the day of transplantation. After the native Achilles tendon was resected from the left hind limb of the rats, Achilles allograft, with or without autologous MSCs, was implanted and sutured with calf muscles proximally and calcaneus distally. Animal gait was recorded presurgery and postsurgery weekly. The animals were sacrificed at week 4, and the transplanted Achilles allografts were collected for biomechanical testing and histology. The operated limbs had altered gait. By week 4, the paw print intensity, stance time, and duty cycle (percentage of the stance phase in a step cycle) of the reconstructed limbs were mostly recovered to the baselines recorded before surgery. Maximum load of failure was not different between Achilles allografts, with or without MSCs, and the native tendons. The Achilles allograft supplemented with MSCs had higher cellularity than the Achilles allograft without MSCs. Deposition of fine collagen (type III) fibers was active in Achilles allograft, with or without MSCs, but it was more evenly distributed in the allografts that were incubated with MSCs. In conclusion, orthotopically transplanted Achilles allograft healed with host tissues, regained strength, and largely restored Achilles function in 4 wk in rats. It is therefore a viable option for the reconstruction of a large Achilles tendon defect. Supplementation of MSCs improved repopulation of Achilles allograft, but large animal models, with long-term follow up and cell tracking, may be required to fully

  4. Bone marrow-derived mesenchymal stem cells influence early tendon-healing in a rabbit achilles tendon model.

    Science.gov (United States)

    Chong, Alphonsus K S; Ang, Abel D; Goh, James C H; Hui, James H P; Lim, Aymeric Y T; Lee, Eng Hin; Lim, Beng Hai

    2007-01-01

    A repaired tendon needs to be protected for weeks until it has accrued enough strength to handle physiological loads. Tissue-engineering techniques have shown promise in the treatment of tendon and ligament defects. The present study tested the hypothesis that bone marrow-derived mesenchymal stem cells can accelerate tendon-healing after primary repair of a tendon injury in a rabbit model. Fifty-seven New Zealand White rabbits were used as the experimental animals, and seven others were used as the source of bone marrow-derived mesenchymal stem cells. The injury model was a sharp complete transection through the midsubstance of the Achilles tendon. The transected tendon was immediately repaired with use of a modified Kessler suture and a running epitendinous suture. Both limbs were used, and each side was randomized to receive either bone marrow-derived mesenchymal stem cells in a fibrin carrier or fibrin carrier alone (control). Postoperatively, the rabbits were not immobilized. Specimens were harvested at one, three, six, and twelve weeks for analysis, which included evaluation of gross morphology (sixty-two specimens), cell tracing (twelve specimens), histological assessment (forty specimens), immunohistochemistry studies (thirty specimens), morphometric analysis (forty specimens), and mechanical testing (sixty-two specimens). There were no differences between the two groups with regard to the gross morphology of the tendons. The fibrin had degraded by three weeks. Cell tracing showed that labeled bone marrow-derived mesenchymal stem cells remained viable and present in the intratendinous region for at least six weeks, becoming more diffuse at later time-periods. At three weeks, collagen fibers appeared more organized and there were better morphometric nuclear parameters in the treatment group (p tendon repair can improve histological and biomechanical parameters in the early stages of tendon-healing.

  5. Arthrography of the biceps tendon

    International Nuclear Information System (INIS)

    Ahovuo, J.; Linden, H.; Hovi, I.; Paavolainen, P.; Bjoerkenheim, J.M.

    1988-01-01

    The purpose of this study was to analyse the factors having an influence on the arthrographic imaging of the biceps tendon. The study comprised 174 patients suffering from chronic shoulder pain. They underwent conventional shoulder arthrography with sodium meglumine metrizoate or metrizamide as a contrast medium. In the patients with a full-thickness tear of the rotator cuff, the biceps tendon sheath failed to fill with contrast medium more often than in those with an intact tendinous cuff. Metrizamide filled the biceps tendon sheath more readily than sodium meglumine metrizoate in patients with a full-thickness tear of the ortator cuff. The volume of the contrast medium injected had no influence on the imaging of the biceps tendon. (orig.)

  6. Flexor digitorum profundus tendon anatomy in the forearm

    Directory of Open Access Journals (Sweden)

    Teoman Dogan

    2012-04-01

    Methods: We used 11 forearms belonging to cadavers and fixed with formaldehyde. The forearms numbered 1, 2, 8, 9, 10, 11 were the left and right arms of the same cadavers. Those numbered 3, 4, 5, 6, 7 belonged to different cadavers. Dissections were made by using the atraumatic surgical technique. The tendons were studied to identify the structure and number of the fibers forming them. Results: The presence of a large common tendon was found in 10 of the 11 forearms. In 4 of these, the common tendon included the tendons of all four fingers. While the common tendon included 3 fingers in four forearms, it only included tendons belonging to 2 fingers in two forearms. It was not possible in one forearm to separate the common tendon into its fibers. In another forearm, tendons belonging to each digit were separate and independent starting at the muscle-tendon junction to the attachment points. Conclusion: The majority of the cadaver forearms used in the study displayed a single large FDP tendon in the zone between the muscle-tendon joint to the carpal tunnel entry prior to being distributed into each index. This anatomical feature should be considered in choosing materials and surgical technique for Zone V FDP tendon injuries, as well as in planning the rehabilitation process. [Hand Microsurg 2012; 1(1.000: 25-29

  7. Grasp Assist Device with Shared Tendon Actuator Assembly

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Bergelin, Bryan J. (Inventor); Bridgwater, Lyndon (Inventor)

    2015-01-01

    A grasp assist device includes a glove with first and second tendon-driven fingers, a tendon, and a sleeve with a shared tendon actuator assembly. Tendon ends are connected to the respective first and second fingers. The actuator assembly includes a drive assembly having a drive axis and a tendon hook. The tendon hook, which defines an arcuate surface slot, is linearly translatable along the drive axis via the drive assembly, e.g., a servo motor thereof. The flexible tendon is routed through the surface slot such that the surface slot divides the flexible tendon into two portions each terminating in a respective one of the first and second ends. The drive assembly may include a ball screw and nut. An end cap of the actuator assembly may define two channels through which the respective tendon portions pass. The servo motor may be positioned off-axis with respect to the drive axis.

  8. [Reconstruction of the heel in a two-year-old boy after lawn mower injury].

    Science.gov (United States)

    Kraus, R; Albrecht, J; Schnettler, R; von Pichler, M

    2012-04-01

    Lawn mower injuries in children usually involve the lower extremities and can lead to serious amputation injuries. Treatment should look not only at the acute reconstruction, but also on maintaining the ability to grow. We report the case of a two-year-old boy with amputation of the heel. The boy was run over by a lawn mower. He suffered a complete loss of heel soft tissue, 30 % of the os calcis and the Achilles tendon. The one-stage reconstruction was performed by transplantation of an iliac crest graft, fascia lata to reconstruct the Achilles tendon and a microvascular latissimus dorsi flap. After one year, the functional and cosmetic result is excellent, the bone graft is healed completely and shows growth trends. The successful treatment of such a severe amputation injury requires the interdisciplinary cooperation between paediatric traumatologists, plastic surgeons, physical therapists and orthopaedic shoemaker. The result justifies the great effort. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Thompson Test in Achilles Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Spencer Albertson

    2016-07-01

    Full Text Available HPI: A 26-year old male presented to the emergency department after experiencing the acute onset of left ankle pain while playing basketball. Upon jumping, he felt a “pop” in his left posterior ankle, followed by pain and difficulty ambulating. His exam was notable for a defect at the left Achilles tendon on palpation. The practitioner performed a Thompson test, which was positive (abnormal on the left. Significant Findings: The left Achilles tendon had a defect on palpation, while the right Achilles tendon was intact. When squeezing the right (unaffected calf, the ankle spontaneously plantar flexed, indicating a negative (normal Thompson test. Upon squeeze of the left (affected calf, the ankle did not plantar flex, signifying a positive (abnormal Thompson test. The diagnosis of left Achilles tendon rupture was confirmed intraoperatively one week later. Discussion: The Achilles tendon (also: calcaneal tendon or heel cord is derived from the medial and lateral heads of the gastrocnemius muscle, as well as the soleus muscle. Rupture of the Achilles tendon most commonly occurs in the distal tendon, approximately 2-6 cm from its attachment to the calcaneal tuberosity, in an area of hypovascularity known as the “watershed” or “critical” zone.1-3 The Thompson test (also: Simmonds-Thompson test, described by Simmonds in 1957 and Thompson in 1962, is done while the patient is in the prone position, with feet hanging over the end of a table/gurney, or with the patient kneeling on a stool or chair.4-5 Squeezing the calf of an unaffected limb will cause the ankle to plantar flex, but squeezing the calf of a limb with an Achilles tendon rupture will cause no motion. The sensitivity of the Thompson’s test for the diagnosis of a complete Achilles tendon rupture is 96-100% and the specificity is 93-100%, but data is limited.6-8

  10. Evidence-Based ACL Reconstruction

    Directory of Open Access Journals (Sweden)

    E. Carlos RODRIGUEZ-MERCHAN

    2015-01-01

    Full Text Available There is controversy in the literature regarding a number of topics related to anterior cruciate ligament (ACLreconstruction. The purpose of this article is to answer the following questions: 1 Bone patellar tendon bone (BPTB reconstruction or hamstring reconstruction (HR; 2 Double bundle or single bundle; 3 Allograft or authograft; 4 Early or late reconstruction; 5 Rate of return to sports after ACL reconstruction; 6 Rate of osteoarthritis after ACL reconstruction. A Cochrane Library and PubMed (MEDLINE search of systematic reviews and meta-analysis related to ACL reconstruction was performed. The key words were: ACL reconstruction, systematic reviews and meta-analysis. The main criteria for selection were that the articles were systematic reviews and meta-analysesfocused on the aforementioned questions. Sixty-nine articles were found, but only 26 were selected and reviewed because they had a high grade (I-II of evidence. BPTB-R was associated with better postoperative knee stability but with a higher rate of morbidity. However, the results of both procedures in terms of functional outcome in the long-term were similar. The double-bundle ACL reconstruction technique showed better outcomes in rotational laxity, although functional recovery was similar between single-bundle and double-bundle. Autograft yielded better results than allograft. There was no difference between early and delayed reconstruction. 82% of patients were able to return to some kind of sport participation. 28% of patients presented radiological signs of osteoarthritis with a follow-up of minimum 10 years.

  11. Extensile posterior approach to the ankle with detachment of the achilles tendon for oncologic indications.

    Science.gov (United States)

    Maheshwari, Aditya V; Walters, Jason A; Henshaw, Robert M

    2012-05-01

    We describe an extensile posterior approach to the ankle with detachment of the Achilles tendon for resection of extensive tumors involving the posterior ankle. To the best of our knowledge, this approach and its results have not been reported for oncologic indications. The surgical technique involved detachment of the Achilles tendon, tumor resection and reconstruction of the Achilles tendon with anchor sutures, and was used in six patients. The diagnosis was pigmented villonodular synovitis (5) and chondroblastoma (1). At a mean of 6 (range, 2 to 10) years followup, all patients were free from tumor. All patients could walk an unlimited amount without any support. There were no problems with Achilles incompetence. The mean Musculoskeletal Tumor Society score was 97 ± 4.2% (range, 90 to 100) and the mean Achilles Tendon Total Rupture Score was 95 ± 5.7 (range, 87 to 100). One patient with screwed suture anchors had backing out of two anchors along with deep infection, requiring surgical debridement and anchor removal. One other patient had a post-traumatic small wound dehiscence which responded to local wound care. Excellent exposure, tumor control and patient function were achieved by this approach in a select group of patients. The surgical technique described in this report offers another alternative for an extensile posterior approach to the ankle and/or subtalar joints.

  12. Biomechanical and histologic comparison of Achilles tendon ruptures reinforced with intratendinous and peritendinous plantaris tendon grafts in rabbits: an experimental study.

    Science.gov (United States)

    Ilhami, Kuru; Gokhan, Maralcan; Ulukan, Inan; Eray, Bozan M; Levent, Altinel; Ciğdem, Tokyol

    2004-11-01

    We hypothesized that the closer the reinforcing graft was to the repair zone, the more strength the healed tendon would achieved. Therefore, we compared the ruptured rabbit Achilles tendons reinforced with intratendinous and peritendinous plantaris grafts. The experimental study was performed on Achilles tendons of 20 rabbits. First, they were divided into two groups: group I (n=10) underwent intratendinous graft and end-to-end tenorraphy, and group P (n=10) were repaired end-to-end and then reinforced with a peritendinous plantaris graft. An above-knee cast was applied during 6 weeks postoperatively. The two groups were compared to each other biomechanically and histologically. Seven randomly selected rabbits from each group were used for biomechanical evaluation. The remaining six rabbits (three from each group) were used for histologic comparison. Non-operated sides (n=20) served as the control group. The mean maximum load at rupture of the repaired and control groups was 159.9+/-31 N, 83+/-7.5 N, and 207.5+/-35 N for group I, group P, and the control group, respectively. Values between groups were significantly different considering maximum load and absorbed energy to rupture. There was no significant difference between groups I and P in respect to strain. Control group tendons (groups I-C and P-C) had significantly more lengthening capability than operated tendons. Macroscopically, group I tendons were thicker and stiffer than group P tendons. Histologically, differences between the group I and group P specimens revealed that the healing process was faster in tendons augmented intratendinously. In reinforcing Achilles tendon repair, the site of the tendon graft affected the result. When the graft was used intratendinously, the healed tendon was more similar biomechanically to normal tendon and had more graft-tendon orientation histologically than the tendon augmented peritendinously.

  13. Simultaneous bilateral patellar tendon rupture ?

    OpenAIRE

    Moura, Diogo Lino; Marques, Jos? Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2016-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a s...

  14. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons.

    Science.gov (United States)

    Thorpe, Chavaunne T; Godinho, Marta S C; Riley, Graham P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2015-12-01

    While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Intraoperative extracorporeal autogenous irradiated tendon grafts for functional limb salvage surgery of soft tissue sarcomas of the wrist and hand.

    Science.gov (United States)

    Omori, Shinsuke; Hamada, Kenichiro; Outani, Hidetatsu; Oshima, Kazuya; Joyama, Susumu; Tomita, Yasuhiko; Naka, Norifumi; Araki, Nobuhito; Yoshikawa, Hideki

    2015-05-12

    In patients with soft tissue sarcoma of the wrist and hand, limb salvage operation is extremely challenging for surgeons in attempting a complete tumor resection with negative surgical margins. In this study, we report four patients with soft tissue sarcoma of the wrist and hand treated by limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts. The patients were all male, and the mean age at the time of surgery was 45 years. Histological diagnoses included clear cell sarcoma in two patients, synovial sarcoma in one, and angiosarcoma in one. All four patients had high grade tumors, wherein three had American Joint Committee on Cancer (AJCC) stage III disease and one with AJCC stage IV disease. The tumors were resected en bloc with involved tendons. The tendons were isolated from the resected tissues, irradiated ex vivo, and re-implanted into the host tendons. In one patient, the bone was resected additionally because of tumor invasion to the bone. Hand function was evaluated using Musculoskeletal Tumor Society (MSTS) rating system. Of the four patients, three died of distant metastatic disease. The remaining patient lives and remains disease-free. The mean follow-up period was 33 months. One patient had local recurrence outside the irradiated graft at 20 months after surgery. The functional rating was 22. Lower scores were seen in patients with reconstruction of flexor tendons than extensor tendons. Limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts is an acceptable method in selected patients with soft tissue sarcoma of the wrist and hand.

  16. TGIF1 Gene Silencing in Tendon-Derived Stem Cells Improves the Tendon-to-Bone Insertion Site Regeneration

    Directory of Open Access Journals (Sweden)

    Liyang Chen

    2015-11-01

    Full Text Available Background/Aims: The slow healing process of tendon-to-bone junctions can be accelerated via implanted tendon-derived stem cells (TDSCs with silenced transforming growth interacting factor 1 (TGIF1 gene. Tendon-to-bone insertion site is the special form of connective tissues derivatives of common connective progenitors, where TGF-β plays bidirectional effects (chondrogenic or fibrogenic through different signaling pathways at different stages. A recent study revealed that TGF-β directly induces the chondrogenic gene Sox9. However, TGIF1 represses the expression of the cartilage master Sox9 gene and changes its expression rate against the fibrogenesis gene Scleraxis (Scx. Methods: TGIF1 siRNA was transduced or TGIF1 was over-expressed in tendon-derived stem cells. Following suprapinatus tendon repair, rats were either treated with transduced TDSCs or nontransduced TDSCs. Histologic examination and Western blot were performed in both groups. Results: In this study, the silencing of TGIF1 significantly upregulated the chondrogenic genes and markers. Similarly, TGIF1 inhibited TDSC differentiation into cartilage via interactions with TGF-β-activated Smad2 and suppressed the phosphorylation of Smad2. The area of fibrocartilage at the tendon-bone interface was significantly increased in the TGIF1 (- group compared with the control and TGIF1-overexpressing groups in the early stages of the animal model. The interface between the tendon and bone showed a increase of new bone and fibrocartilage in the TGIF1 (- group at 4 weeks. Fibrovascular scar tissue was observed in the TGIF1-overexpressing group and the fibrin glue only group. Low levels of fibrocartilage and fibrovascular scar tissue were found in the TDSCs group. Conclusion: Collectively, this study shows that the tendon-derived stem cell modified with TGIF1 gene silencing has promising effects on tendon-to-bone healing which can be further explored as a therapeutic tool in regenerative medicine.

  17. FRP tendon anchorage in post-tensioned concrete structures

    DEFF Research Database (Denmark)

    Schmidt, Jacob Wittrup; Täljsten, Björn; Bennitz, Anders

    2008-01-01

    effective Young´s modulus and the high stress capacity in the linear elastic range of the material. The use of external tendons increases the requirements on the anchorage systems. This is in particular important when using un-bonded tendon systems, where the anchorage and deviators are the only force...... transfer points. The demand for high capacity anchorage tendons is fulfilled for steel tendons, but no competitive mechanical anchor has yet been developed for FRP tendon. A new small, reliable and more user friendly anchor has to be developed, before FRP tendons can be utilized with all of its capacity...

  18. MR Imaging and US of the Wrist Tendons.

    Science.gov (United States)

    Plotkin, Benjamin; Sampath, Srihari C; Sampath, Srinath C; Motamedi, Kambiz

    2016-10-01

    The tendons of the wrist are commonly symptomatic. They can be injured, infected, or inflamed. Magnetic resonance imaging and ultrasonography are useful tools for evaluating the wrist. Pathologic conditions of the wrist tendons include de Quervain tenosynovitis, extensor carpi ulnaris tendinopathy, rheumatoid tenosynovitis, infectious synovitis, tendon tears, hydroxyapatite deposition disease, intersection syndrome, tenosynovial giant cell tumor, and fibroma of the tendon sheath. In this article, we review the normal appearance of the wrist tendons, discuss relevant anatomy, and give an overview of common pathologic conditions affecting the wrist tendons. Online supplemental material is available for this article. © RSNA, 2016.

  19. Repair of Achilles tendon defect with autologous ASCs engineered tendon in a rabbit model.

    Science.gov (United States)

    Deng, Dan; Wang, Wenbo; Wang, Bin; Zhang, Peihua; Zhou, Guangdong; Zhang, Wen Jie; Cao, Yilin; Liu, Wei

    2014-10-01

    Adipose derived stem cells (ASCs) are an important cell source for tissue regeneration and have been demonstrated the potential of tenogenic differentiation in vitro. This study explored the feasibility of using ASCs for engineered tendon repair in vivo in a rabbit Achilles tendon model. Total 30 rabbits were involved in this study. A composite tendon scaffold composed of an inner part of polyglycolic acid (PGA) unwoven fibers and an outer part of a net knitted with PGA/PLA (polylactic acid) fibers was used to provide mechanical strength. Autologous ASCs were harvested from nuchal subcutaneous adipose tissues and in vitro expanded. The expanded ASCs were harvested and resuspended in culture medium and evenly seeded onto the scaffold in the experimental group, whereas cell-free scaffolds served as the control group. The constructs of both groups were cultured inside a bioreactor under dynamic stretch for 5 weeks. In each of 30 rabbits, a 2 cm defect was created on right side of Achilles tendon followed by the transplantation of a 3 cm cell-seeded scaffold in the experimental group of 15 rabbits, or by the transplantation of a 3 cm cell-free scaffold in the control group of 15 rabbits. Animals were sacrificed at 12, 21 and 45 weeks post-surgery for gross view, histology, and mechanical analysis. The results showed that short term in vitro culture enabled ASCs to produce matrix on the PGA fibers and the constructs showed tensile strength around 50 MPa in both groups (p > 0.05). With the increase of implantation time, cell-seeded constructs gradually form neo-tendon and became more mature at 45 weeks with histological structure similar to that of native tendon and with the presence of bipolar pattern and D-periodic structure of formed collagen fibrils. Additionally, both collagen fibril diameters and tensile strength increased continuously with significant difference among different time points (p tendon tissue with fibril structure observable only at 45 weeks

  20. Peroneal tendon displacement accompanying intra-articular calcaneal fractures.

    Science.gov (United States)

    Toussaint, Rull James; Lin, Darius; Ehrlichman, Lauren K; Ellington, J Kent; Strasser, Nicholas; Kwon, John Y

    2014-02-19

    Peroneal tendon displacement (subluxation or dislocation) accompanying an intra-articular calcaneal fracture is often undetected and under-treated. The goals of this study were to determine (1) the prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures, (2) the association of tendon displacement with fracture classifications, (3) the association of tendon displacement with heel width, and (4) the rate of missed diagnosis of the tendon displacement on radiographs and computed tomography (CT) scans and the resulting treatment rate. A retrospective radiographic review of all calcaneal fractures presenting at three institutions from June 30, 2006, to June 30, 2011, was performed. CT imaging of 421 intra-articular calcaneal fractures involving the posterior facet was available for review. The prevalence of peroneal tendon displacement was noted and its associations with fracture classification and heel width were evaluated. Peroneal tendon displacement was identified in 118 (28.0%) of the 421 calcaneal fracture cases. The presence of tendon displacement was significantly associated with joint-depression fractures compared with tongue-type fractures (p displacement had been identified in the radiology reports. Although sixty-five (55.1%) of the fractures with tendon displacement had been treated with internal fixation, the tendon displacement was treated surgically in only seven (10.8%) of these cases. Analysis of CT images showed a 28% prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures. Surgeons and radiologists are encouraged to consider this association.

  1. Reconstruction of a Total Soft Palatal Defect Using

    Directory of Open Access Journals (Sweden)

    Won Jai Lee

    2012-01-01

    Full Text Available Background The soft palate functions as a valve and helps generate the oral pressurerequired for normal speech resonance. Speech problems and nasal regurgitation can resultfrom a soft palatal defect. Reduction of the size of the velopharyngeal orifice is requiredto compensate for the lack of mobility in a reconstructed soft palate. We suggest a largevolume folded free flap for reduction of the caliber and a palmaris longus tendon sling forsuspension of the reconstructed palate.Methods Six patients had total soft palate resection for tonsillar cancer and reconstructionwith a large volume folded radial forearm free flap combined with a palmaris longus sling.A single surgeon and speech therapist examined the patients with three standardizedspeech assessment tools: nasometer test, consonant articulation test, and speech acuity testperformed for speech evaluation.Results Mean nasalance score was 76.20% for sentences with nasal sounds and 43.60% forsentences with oral sounds. Hypernasality was seen for oral sound sentences. The mean scoreof the picture consonant articulation test was 84% (range, 63% to 100%. The mean scoreof the speech acuity test was 5.84 (range, 5 to 6. These mean ratings represent a satisfactorylevel of speech function.Conclusions The large volume folded free flap with a palmaris longus tendon sling for totalsoft palate reconstruction resulted in satisfactory prognosis for speech despite moderatehypernasality.

  2. [Free tissue transfers with lengthening of vascular pedicle using interpositional vein grafts. About 10 cases].

    Science.gov (United States)

    Yeo, S; Perrot, P; Duteille, F

    2010-04-01

    The realization of free flaps with lack of reliable vessels nearby the loss of substance is a difficult problem for plastic surgeons. We report 10 cases of free tissue transfers with a one-stage technique lengthening the vascular pedicle of the free flap with interpositional vein grafts. Taking into consideration the good results and the low rate of morbidity, the authors emphasize the use of this technique rather than a two-stage procedure. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  3. Role of biomechanics in the understanding of normal, injured, and healing ligaments and tendons

    Directory of Open Access Journals (Sweden)

    Jung Ho-Joong

    2009-05-01

    Full Text Available Abstract Ligaments and tendons are soft connective tissues which serve essential roles for biomechanical function of the musculoskeletal system by stabilizing and guiding the motion of diarthrodial joints. Nevertheless, these tissues are frequently injured due to repetition and overuse as well as quick cutting motions that involve acceleration and deceleration. These injuries often upset this balance between mobility and stability of the joint which causes damage to other soft tissues manifested as pain and other morbidity, such as osteoarthritis. The healing of ligament and tendon injuries varies from tissue to tissue. Tendinopathies are ubiquitous and can take up to 12 months for the pain to subside before one could return to normal activity. A ruptured medial collateral ligament (MCL can generally heal spontaneously; however, its remodeling process takes years and its biomechanical properties remain inferior when compared to the normal MCL. It is also known that a midsubstance anterior cruciate ligament (ACL tear has limited healing capability, and reconstruction by soft tissue grafts has been regularly performed to regain knee function. However, long term follow-up studies have revealed that 20–25% of patients experience unsatisfactory results. Thus, a better understanding of the function of ligaments and tendons, together with knowledge on their healing potential, may help investigators to develop novel strategies to accelerate and improve the healing process of ligaments and tendons. With thousands of new papers published in the last ten years that involve biomechanics of ligaments and tendons, there is an increasing appreciation of this subject area. Such attention has positively impacted clinical practice. On the other hand, biomechanical data are complex in nature, and there is a danger of misinterpreting them. Thus, in these review, we will provide the readers with a brief overview of ligaments and tendons and refer them to

  4. Role of biomechanics in the understanding of normal, injured, and healing ligaments and tendons

    Science.gov (United States)

    Jung, Ho-Joong; Fisher, Matthew B; Woo, Savio L-Y

    2009-01-01

    Ligaments and tendons are soft connective tissues which serve essential roles for biomechanical function of the musculoskeletal system by stabilizing and guiding the motion of diarthrodial joints. Nevertheless, these tissues are frequently injured due to repetition and overuse as well as quick cutting motions that involve acceleration and deceleration. These injuries often upset this balance between mobility and stability of the joint which causes damage to other soft tissues manifested as pain and other morbidity, such as osteoarthritis. The healing of ligament and tendon injuries varies from tissue to tissue. Tendinopathies are ubiquitous and can take up to 12 months for the pain to subside before one could return to normal activity. A ruptured medial collateral ligament (MCL) can generally heal spontaneously; however, its remodeling process takes years and its biomechanical properties remain inferior when compared to the normal MCL. It is also known that a midsubstance anterior cruciate ligament (ACL) tear has limited healing capability, and reconstruction by soft tissue grafts has been regularly performed to regain knee function. However, long term follow-up studies have revealed that 20–25% of patients experience unsatisfactory results. Thus, a better understanding of the function of ligaments and tendons, together with knowledge on their healing potential, may help investigators to develop novel strategies to accelerate and improve the healing process of ligaments and tendons. With thousands of new papers published in the last ten years that involve biomechanics of ligaments and tendons, there is an increasing appreciation of this subject area. Such attention has positively impacted clinical practice. On the other hand, biomechanical data are complex in nature, and there is a danger of misinterpreting them. Thus, in these review, we will provide the readers with a brief overview of ligaments and tendons and refer them to appropriate methodologies used to

  5. Icariin Promotes Tendon-Bone Healing during Repair of Rotator Cuff Tears: A Biomechanical and Histological Study.

    Science.gov (United States)

    Ye, Chenyi; Zhang, Wei; Wang, Shengdong; Jiang, Shuai; Yu, Yuanbin; Chen, Erman; Xue, Deting; Chen, Jianzhong; He, Rongxin

    2016-10-25

    To investigate whether the systematic administration of icariin (ICA) promotes tendon-bone healing after rotator cuff reconstruction in vivo, a total of 64 male Sprague Dawley rats were used in a rotator cuff injury model and underwent rotator cuff reconstruction (bone tunnel suture fixation). Rats from the ICA group ( n = 32) were gavage-fed daily with ICA at 0.125 mg/g, while rats in the control group ( n = 32) received saline only. Micro-computed tomography, biomechanical tests, serum ELISA (calcium; Ca, alkaline phosphatase; AP, osteocalcin; OCN) and histological examinations (Safranin O and Fast Green staining, type I, II and III collagen (Col1, Col2, and Col3), CD31, and vascular endothelial growth factor (VEGF)) were analyzed two and four weeks after surgery. In the ICA group, the serum levels of AP and OCN were higher than in the control group. More Col1-, Col2-, CD31-, and VEGF-positive cells, together with a greater degree of osteogenesis, were detected in the ICA group compared with the control group. During mechanical testing, the ICA group showed a significantly higher ultimate failure load than the control group at both two and four weeks. Our results indicate that the systematic administration of ICA could promote angiogenesis and tendon-bone healing after rotator cuff reconstruction, with superior mechanical strength compared with the controls. Treatment for rotator cuff injury using systematically-administered ICA could be a promising strategy.

  6. The 'bridging sign', a MR finding for combined full-thickness tears of the subscapularis tendon and the supraspinatus tendon

    International Nuclear Information System (INIS)

    Jung, Jin Young; Yoon, Young Cheol; Cha, Dong Ik; Yoo, Jae-Chul; Jung, Jee Young

    2013-01-01

    Background: In daily practice, we discovered one of the secondary magnetic resonance (MR) findings of the subscapularis (SSC) tendon tear, the 'bridging sign', which has not been previously described. Purpose: To describe the 'bridging sign' on shoulder MR imaging and its radiological and clinical significance in patients with SSC tendon tear. Material and Methods: Twenty-nine patients who had undergone shoulder arthroscopy and had full-thickness tear of the subscapularis tendon were enrolled. The medical records of the 29 patients were retrospectively reviewed for the duration of shoulder pain, rotator cuff tears, and associated arthroscopic findings: biceps tendon abnormality and superior glenoid labral tear. Then, preoperative shoulder MR images were retrospectively reviewed for the presence or absence of the 'bridging sign' and associated MR findings: periarticular fluid and fatty atrophy of the supraspinatus and subscapularis muscles. The type of rotator cuff tear associated with the 'bridging sign' was assessed and the sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of a certain type of rotator cuff tear were calculated. Associated arthroscopic and MR findings and mean duration of the shoulder pain between the patients with and without the 'bridging sign' were compared. Results: The 'bridging sign' was seen in 17 of 29 patients and corresponded to a complex of the torn and superomedially retracted subscapularis tendon, coracohumeral ligament, and superior glenohumeral ligament, adhered to the anterior margin of the torn supraspinatus (SSP) tendon on arthroscopy. All patients with the 'bridging sign' had combined full-thickness tear (FTT) of the cranial 1/2 portion of the subscapularis tendon and anterior 1/2 portion of the SSP tendon. The sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of combined FTTs of the SSC tendon and anterior portion of the SSP tendon were 81.0%, 100%, and 86

  7. Simultaneous bilateral anterior cruciate ligament reconstruction: Cost comparison and functional results

    Directory of Open Access Journals (Sweden)

    Matjaž Sajovic

    2014-04-01

    Full Text Available Background: The ideal treatment for patients presenting with bilateral anterior cruciate ligament (ACL deficiency remains controversial. The purpose was to evaluate cost and mid-term functional results after one-stage bilateral ACL reconstruction using either hamstring or patella tendon autograft.Methods: We compared the mid-term outcome of 7 patients (14 knees who had one-stage bilateral ACL reconstruction with that of a matched group of patients who had unilateral reconstruction (21 patients.Results: The median duration of hospital stay was 4 nights (range 3 to 5 for the bilateral group and 2 nights (range, 1 to 4 for the control group. The duration of rehabilitation process in patients from the control group with unilateral ACL reconstruction was one week shorter (9 versus 8 weeks. In the bilateral group, the median Lysholm score was 96 (range 85–100 and in the control group, the median score was 93 (range 81–100. The median time to return to full-time work and to full sports was 9 weeks and 7 months for the simultaneous bilateral group and 8 weeks and 6 months for the unilateral group. Six patients (86 % in the bilateral group and 17 patients (81 % in the control group were still performing at their pre-injury level of activity. The Health Insurance Institute of Slovenia saves EUR 2,925 when we perform simultaneous bilateral ACL reconstruction instead of two stage ACL reconstruction.Conclusions: Mid-term clinical results suggested that simultaneous bilateral ACL reconstruction using either hamstring or patella tendon autograft is clinically effective. For patients presenting with symptomatic bilateral ACL deficient knees, one stage bilateral ACL reconstruction is reproducible, cost effective, and does not compromise functional results.

  8. Fetal development of the pulley for muscle insertion tendons: A review and new findings related to the tensor tympani tendon.

    Science.gov (United States)

    Rodríguez-Vázquez, Jose Francisco; Honkura, Yohei; Katori, Yukio; Murakami, Gen; Abe, Hiroshi

    2017-01-01

    The existence of hard tissue pulleys that act to change the direction of a muscle insertion tendon is well known in the human body. These include (1) the trochlea for the extraocular obliquus superior muscle, (2) the pterygoid hamulus for the tensor veli palatini muscle, (3) the deep sulcus on the plantar aspect of the cuboid bone for the peroneus longus tendon, (4) the lesser sciatic notch for the obturator internus muscle, and (5) the bony trochleariformis process for the tensor tympani muscle tendon. In addition, (6) the stapedius muscle tendon shows a lesser or greater angulation at the pyramidal eminence of the temporal bone. Our recent studies have shown that the development of pulleys Nos. 1 and 2 can be explained by a change in the topographical relationship between the pulley and the tendon, that of pulley No. 3 by the rapidly growing calcaneus pushing the tendon, and that of pulley No. 4 by migration of the insertion along the sciatic nerve and gluteus medius tendon. Therefore, in Nos. 1-4, an initially direct tendon curves secondarily and obtains an attachment to the pulley. In case No. 6, the terminal part of the stapedius tendon originates secondarily from the interzone mesenchymal tissue of the incudostapedial joint. In the case of pulley No. 5, we newly demonstrated that its initial phase of development was similar to No. 6, but the tensor tympani tendon achieved a right-angled turn under guidance by a specific fibrous tissue and it migrated along the growing malleus manubrium. Copyright © 2016 Elsevier GmbH. All rights reserved.

  9. Imaging the infrapatellar tendon in the elite athlete

    International Nuclear Information System (INIS)

    Peace, K.A.L.; Lee, J.C.; Healy, J.

    2006-01-01

    Extensor mechanism injuries constitute a major cause of anterior knee pain in the elite athlete. Sonography and magnetic resonance imaging (MRI) are the imaging methods of choice when assessing the infrapatellar tendon. A comprehensive imaging review of infrapatellar tendon normal anatomy, tendinopathy, and partial/full-thickness tendon tears is provided. The value of imaging the infrapatellar tendon in clinical practice, including whether sonography can predict symptoms in asymptomatic athletes, is discussed. Acute avulsion fractures, including periosteal sleeve avulsion, and chronic avulsion injuries, including Sinding-Larsen-Johansson and Osgood-Schlatter syndromes, are shown. Mimics of infrapatellar tendon pathology, including infrapatellar plica injury, patellar tendon-lateral femoral condyle friction syndrome, and Hoffa's syndrome, are illustrated

  10. About tendon tissue regeneration in experimental radiation disease

    Energy Technology Data Exchange (ETDEWEB)

    Popov, D; Trichkova, P

    1976-01-01

    Under the conditions of experimental acute radiation disease the authors study the tendon tissue regeneration after suture of the lateral part of the gastrocnemius muscle tendon. Tendon auto and alloplasty were applied. In four postoperative periods the histological features are described in details as well as the characteristic phenomena observed during the regeneration influenced to a considerable degree by the irradiation. Round cell infiltration, large necrotic zones, erythrocyte infiltrations as well as predominance of non-specific tendon regeneration long after the surgery characterize the recovery period of the traumatically damaged tendon, nevertheless that at the end there is real tendon regeneration even though in a longer period in comparison with the controls (non-irradiated animals).

  11. Spontaneous Achilles tendon rupture in alkaptonuria | Mohammed ...

    African Journals Online (AJOL)

    Spontaneous Achilles tendon ruptures are uncommon. We present a 46-year-old man with spontaneous Achilles tendon rupture due to ochronosis. To our knowledge, this has not been previously reported in Sudan literature. The tendon of the reported patient healed well after debridement and primary repairs.

  12. Plantar tendons of the foot: MR imaging and US.

    Science.gov (United States)

    Donovan, Andrea; Rosenberg, Zehava Sadka; Bencardino, Jenny T; Velez, Zoraida Restrepo; Blonder, David B; Ciavarra, Gina A; Adler, Ronald Steven

    2013-01-01

    Tendon disorders along the plantar aspect of the foot may lead to significant symptoms but are often clinically misdiagnosed. Familiarity with the normal anatomy of the plantar tendons and its appearance at magnetic resonance (MR) imaging and ultrasonography (US) is essential for recognizing plantar tendon disorders. At MR imaging, the course of the plantar tendons is optimally visualized with dedicated imaging of the midfoot and forefoot. This imaging should include short-axis images obtained perpendicular to the long axis of the metatarsal shafts, which allows true cross-sectional evaluation of the plantar tendons. Normal plantar tendons appear as low-signal-intensity structures with all MR sequences. At US, accurate evaluation of the tendons requires that the ultrasound beam be perpendicular to the tendon. The normal tendon appears as a compact linear band of echogenic tissue that contains a fine, mixed hypoechoic and hyperechoic internal fibrillar pattern. Tendon injuries can be grouped into six major categories: tendinosis, peritendinosis, tenosynovitis, entrapment, rupture, and instability (subluxation or dislocation) and can be well assessed with both MR imaging and US. The radiologist plays an important role in the diagnosis of plantar tendon disorders, and recognizing their imaging appearances at MR imaging and US is essential.

  13. Mechanical properties of the human Achilles tendon, in vivo

    DEFF Research Database (Denmark)

    Kongsgaard, M; Nielsen, C H; Hegnsvad, S

    2011-01-01

    Ultrasonography has been widely applied for in vivo measurements of tendon mechanical properties. Assessments of human Achilles tendon mechanical properties have received great interest. Achilles tendon injuries predominantly occur in the tendon region between the Achilles-soleus myotendinous...... junction and Achilles-calcaneus osteotendinous junction i.e. in the free Achilles tendon. However, there has been no adequate ultrasound based method for quantifying the mechanical properties of the free human Achilles tendon. This study aimed to: 1) examine the mechanical properties of the free human...

  14. Preoperative cryotherapy use in anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Koyonos, Loukas; Owsley, Kevin; Vollmer, Emily; Limpisvasti, Orr; Gambardella, Ralph

    2014-12-01

    Unrelieved postoperative pain may impair rehabilitation, compromise functional outcomes, and lead to patient dissatisfaction. Preemptive multimodal analgesic techniques may improve outcomes after surgery. We hypothesized that patients using preoperative cryotherapy plus a standardized postoperative treatment plan will have lower pain scores and require less pain medication compared with patients receiving a standardized postoperative treatment plan alone after arthroscopically assisted anterior cruciate ligament reconstruction (ACLR). A total of 53 consecutive patients undergoing arthroscopically assisted ACLR performed by one of seven surgeons were randomly assigned to one of two groups. Group 1 received no preoperative cryotherapy and group 2 received 30 to 90 minutes of preoperative cryotherapy to the operative leg using a commercial noncompressive cryotherapy unit. Visual analog scale pain scores and narcotic use were recorded for the first 4 days postoperatively. Total hours of cold therapy and continuous passive motion (CPM) use and highest degree of flexion achieved were recorded as well. Group 1 consisted of 26 patients (15 allograft Achilles tendon and 11 autograft bone patellar tendon bone [BPTB]), and group 2 consisted of 27 patients (16 allograft Achilles tendon and 11 autograft BPTB). Group 2 patients reported less pain (average 1.3 units, p cryotherapy, hours of CPM use, or maximum knee flexion achieved. Complications did not occur in either group. This is the first report we are aware of showing the postoperative effects of preoperative cryotherapy. Our results support the safety and efficacy of preoperative cryotherapy in a multimodal pain regimen for patients undergoing ACL reconstruction. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. A Tendon Cell Specific RNAi Screen Reveals Novel Candidates Essential for Muscle Tendon Interaction.

    Directory of Open Access Journals (Sweden)

    Prabhat Tiwari

    Full Text Available Tendons are fibrous connective tissue which connect muscles to the skeletal elements thus acting as passive transmitters of force during locomotion and provide appropriate body posture. Tendon-derived cues, albeit poorly understood, are necessary for proper muscle guidance and attachment during development. In the present study, we used dorsal longitudinal muscles of Drosophila and their tendon attachment sites to unravel the molecular nature of interactions between muscles and tendons. We performed a genetic screen using RNAi-mediated knockdown in tendon cells to find out molecular players involved in the formation and maintenance of myotendinous junction and found 21 candidates out of 2507 RNAi lines screened. Of these, 19 were novel molecules in context of myotendinous system. Integrin-βPS and Talin, picked as candidates in this screen, are known to play important role in the cell-cell interaction and myotendinous junction formation validating our screen. We have found candidates with enzymatic function, transcription activity, cell adhesion, protein folding and intracellular transport function. Tango1, an ER exit protein involved in collagen secretion was identified as a candidate molecule involved in the formation of myotendinous junction. Tango1 knockdown was found to affect development of muscle attachment sites and formation of myotendinous junction. Tango1 was also found to be involved in secretion of Viking (Collagen type IV and BM-40 from hemocytes and fat cells.

  16. Simultaneous bilateral patellar tendon rupture.

    Science.gov (United States)

    Moura, Diogo Lino; Marques, José Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2017-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  17. Rupture of Achilles Tendon : Usefulness of Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Nam Hyeon; Ki, Won Woo; Yoon, Kwon Ha; Kim, Song Mun; Shin, Myeong Jin; Kwon, Soon Tae

    1996-01-01

    To differentiate a complete rupture of Achilles tendon from an incomplete one which is important because its treatment is quite different. And it is necessary to know the exact site of the rupture preoperatively. Fifteen cases of fourteen patients which were diagnosed as Achilles tendon rupture by ultrasonography and surgery were reviewed. We compared sonographic rupture site with surgical findings. Ultrasonographic criteria for differentiation of complete and incomplete rupture was defined as follows : the discreteness, which means the proximal intervening hypoechogenicity to the interface echogenicity of distal margin of ruptured tendon : the slant sign, which represents the interface of ruptured distal margin which was seen over the 3/4 of the thickness of the tendon without intervening low echogeneicity : the invagination sign, which means the echogenic invagination from Kager triangle into posterior aspect of Achilles tendon over the half thickness of the tendon. The sites of complete tendon rupture were exactly corresponded to surgical finding in four cases of ten complete ruptures. And the discrepancy between sonographic and surgical findings in the site of complete rupture was 1.2 ± 0.4 cm in six cases. Three of ten complete ruptures showed the discreteness sign, all of ten showed the slant sign and two of ten showed the invagination sign. It is helpful to differentiate a complete from incomplete rupture of the Achilles tendon and to localize the site of the complete rupture with the ultrasonographic evaluation

  18. Effect of estrogen on tendon collagen synthesis, tendon structural characteristics, and biomechanical properties in postmenopausal women

    DEFF Research Database (Denmark)

    Hansen, Mette; Kongsgaard, Mads; Holm, Lars

    2009-01-01

    and fibril characteristics were determined by MRI and transmission electron microscopy, whereas tendon biomechanical properties were measured during isometric maximal voluntary contraction by ultrasound recording. Tendon FSR was markedly higher in ERT-users (P

  19. Investigations related to failure of prestressing tendons

    International Nuclear Information System (INIS)

    Boyadjiev, Z.

    1995-01-01

    Kozloduy NPP units 5 and 6 containment cladding shells are prestressed by the use of tendons 450 φ 5, made of high strength wires, class B-II. The prestressing force for each tendon is 10000 kN and the calculated breakdown force - 14000 kN. There are 96 tendons in the cylindrical part of the shell and 36 ones located in the containment dome. They are located in channel forming tubes of inner diameter of 200 mm, made of dense polyethylene. In order to assure biaxial prestressed condition, the prestressing tendons are located on screw shaped lines, both left and right, with declination to the horizon 35 degrees and 15 minutes. Each prestressing tendon initially forms a knee and following the bending at elevation + 10.80 m forms the other knee, in such a way, that its two ends are anchored in one and the same area-in a common or adjacent upper anchor boxes. The prestressing tendons in the containment dome are located in two perpendicular rows. Both ends of each tendon are anchored in a common fixing, the tendon being bent to the opposite side of the dome. During construction and operation of units 5 and 6, it was found, that the design prestressing force of 10000 kN can not be reached with some tendons, due to separate wires ruptures or due to the anchoring screw spent thread. The 1992 preliminary wires tests on a failed tendon found out deformation properties, different from the systematically obtained ones for the initial steel. Taking into consideration this fact, together with the IAEA regional project, concerning WWER-1000 seismic safety and items 4 and 6 of Kozloduy NPP Technical Council decisions of 10 June 1993, brought to delegation to the Research Construction Institute the performance of the technical analysis of the applied system for shell prestressing of containments of of units 5 and 6. The analysis comprises physical-mechanical and rheological properties of the high strength wires, used for containment shell prestressing and the over all technological

  20. Glutaraldehyde cross-linking of tendon mechanical effects at the level of the tendon fascicle and fibril

    DEFF Research Database (Denmark)

    Hansen, Philip; Hassenkam, Tue; Svensson, Rene Bruggebusch

    2009-01-01

    at the tendon fibril level were examined by atomic force microscopy. Peak forces increased from approximately 1379 to approximately 2622 pN while an extended Hertz fit of force-indentation data showed a approximately 24 fold increase in Young's modulus on indentation. The effect of glutaraldehyde cross......Conclusive insight into the microscopic principles that govern the strength of tendon and related connective tissues is lacking and the importance of collagen cross-linking has not been firmly established. The combined application of whole-tissue mechanical testing and atomic force spectroscopy...... allowed for a detailed characterization of the effect of cross-linking in rat-tail tendon. The cross-link inducing agent glutaraldehyde augmented the tensile strength of tendon fascicles. Stress at failure increased from approximately 8 MPa to approximately 39 MPa. The mechanical effects of glutaraldehyde...

  1. One-stage treatment of delayed 'jersey finger' by Z-step lengthening of the flexor digitorum profundus tendon at the wrist.

    Science.gov (United States)

    Sawaya, Elias T; Choughri, Hussein; Pelissier, Philippe

    2012-02-01

    The authors report the case of a 19-year-old female with delayed presentation of a type II 'jersey finger' of the fourth dominant digit. A surgical approach was performed, revealing a retracted flexor digitorum profundus tendon within a still patent sheath. The resulting loss of tendon length overruled any possibility of direct reinsertion of the tendon. A lengthening "Z-step" tendinoplasty was then performed on the tendon at the wrist, thus enabling reinsertion at the base of the distal phalanx. The patient then underwent conventional splinting and physiotherapy. Total Active Motion was measured at 220° with a 6-month follow-up. Even though there is no clear consensus concerning management of such cases, different techniques have been described, such as one- or two-stage grafting, or tenotomy at the musculotendinous junction. Lengthening tendinoplasties have been applied by certain authors but only to the flexor pollicis longus tendon. To our knowledge, this is the only reported case of lengthening Z-step applied to a long digit for the repair of type II 'jersey finger' lesions. The satisfactory functional and cosmetic outcome encourages us to consider this one-stage technique in other select cases, in order to gather more formal evidence. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Numerical models for prestressing tendons in containment structures

    International Nuclear Information System (INIS)

    Kwak, Hyo-Gyoung; Kim, Jae Hong

    2006-01-01

    Two modified stress-strain relations for bonded and unbonded internal tendons are proposed. The proposed relations can simulate the post-cracking behavior and tension stiffening effect in prestressed concrete containment structures. In the case of the bonded tendon, tensile forces between adjacent cracks are transmitted from a bonded tendon to concrete by bond forces. Therefore, the constitutive law of a bonded tendon stiffened by grout needs to be determined from the bond-slip relationship. On the other hand, a stress increase beyond the effective prestress in an unbonded tendon is not section-dependent but member-dependent. It means that the tendon stress unequivocally represents a uniform distribution along the length when the friction loss is excluded. Thus, using a strain reduction factor, the modified stress-strain curve of an unbonded tendon is derived by successive iterations. In advance, the prediction of cracking behavior and ultimate resisting capacity of prestressed concrete containment structures using the introduced numerical models are succeeded, and the need for the consideration of many influencing factors such as the tension stiffening effect, plastic hinge length and modification of stress-strain relation of tendon is emphasized. Finally, the developed numerical models are applied to prestressed concrete containment structures to verify the efficiency and applicability in simulating the structural behavior with bonded and/or unbonded tendons

  3. THE ROLE OF DETRAINING IN TENDON MECHANOBIOLOGY

    Directory of Open Access Journals (Sweden)

    Antonio eFrizziero

    2016-02-01

    Full Text Available Introduction: Several conditions such as training, aging, estrogen deficiency and drugs could affect the biological and anatomo-physiological characteristics of the tendon. Additionally, recent preclinical and clinical studies examined the effect of detraining on tendon, showing alterations in its structure and morphology and in tenocyte mechanobiology. However, there is a paucity of data examining the impact that cessation of training may have on tendon. In practice, we do not fully understand how tendons respond to a period of training followed by sudden detraining. Therefore, within this review, we summarize the studies where tendon detraining was examined.Materials and methods: A descriptive systematic literature review was conducted by searching three databases (PubMed, Scopus and Web of Knowledge on tendon detraining. Original articles in English from 2000 to 2015 were included. In addition, the search was extended to the reference lists of the selected articles. A public reference manager (www.mendeley.com was used to delete duplicate articles.Results: An initial literature search yielded 134 references (www.pubmed.org: 53; www.scopus.com: 11; www.webofknowledge.com: 70. 15 publications were extracted based on the title for further analysis by two independent reviewers. Abstracts and whole articles were then reviewed to detect if they met inclusion criteria.Conclusions: The revised literature comprised 4 clinical studies and an in vitro and three in vivo reports. Overall, the results showed that tendon structure and properties after detraining are compromised, with an alteration in the tissue structural organization and mechanical properties. Clinical studies usually showed a lesser extent of tendon alterations, probably because preclinical studies permit an in-depth evaluation of tendon modifications, which is hard to perform in human subjects. In conclusion, after a period of sudden detraining (e.g. after an injury, physical activity

  4. Local trauma in human patellar tendon leads to widespread changes in the tendon gene expression

    DEFF Research Database (Denmark)

    Heinemeier, Katja Maria; Lorentzen, Marc P; Kildevang Jensen, Jacob

    2016-01-01

    Low cellular activity and slow tissue turnover in human tendon may prolong resolution of tendinopathy. This may be stimulated by moderate localized traumas such as needle penetrations, but whether this results in a widespread cellular response in tendons is unknown. In an initial hypothesis-gener...

  5. Tendon overuse syndrome: imaging diagnosis

    International Nuclear Information System (INIS)

    Huber, W.; Nehrer, S.; Muellner, T.; Kainberger, F.; Ulreich, N.; Bernhard, C.; Imhof, H.

    2001-01-01

    Injuries of muscles and tendons occur commonly during various sporting activities and in most cases the athletes feel such an accident to be sudden and unavoidable. The rupture of a tendon, however, has to be considered in many cases as the final stage of a long-standing progressive degeneration of collagen fibers. This process con be described as 'tendon overuse syndrome (TOS)'. Diagnostic imaging modalities, especially sonography and MRI, are suitable to detect and analyse the different stages of this syndrome and the degree of morphological abnormalities. The first stage is painful functional derangement, followed by tendovaginitis, peritendinitis, or bursitis. The third stage is tendinosis resulting from biomechanical or ischaemic injury of tendon fibers which may eventually be followed by partial or complete rupture. Regional or individual specifications of these four stages may occur at anatomically predisposing sites, so-called critical zones, or during periods of specific proneness, the vulnerable phases. (author)

  6. Anterior cruciate ligament reconstruction in a rabbit model using silk-collagen scaffold and comparison with autograft.

    Directory of Open Access Journals (Sweden)

    Fanggang Bi

    Full Text Available The objective of the present study was to perform an in vivo assessment of a novel silk-collagen scaffold for anterior cruciate ligament (ACL reconstruction. First, a silk-collagen scaffold was fabricated by combining sericin-extracted knitted silk fibroin mesh and type I collagen to mimic the components of the ligament. Scaffolds were electron-beam sterilized and rolled up to replace the ACL in 20 rabbits in the scaffold group, and autologous semitendinosus tendons were used to reconstruct the ACL in the autograft control group. At 4 and 16 weeks after surgery, grafts were retrieved and analyzed for neoligament regeneration and tendon-bone healing. To evaluate neoligament regeneration, H&E and immunohistochemical staining was performed, and to assess tendon-bone healing, micro-CT, biomechanical test, H&E and Russell-Movat pentachrome staining were performed. Cell infiltration increased over time in the scaffold group, and abundant fibroblast-like cells were found in the core of the scaffold graft at 16 weeks postoperatively. Tenascin-C was strongly positive in newly regenerated tissue at 4 and 16 weeks postoperatively in the scaffold group, similar to observations in the autograft group. Compared with the autograft group, tendon-bone healing was better in the scaffold group with trabecular bone growth into the scaffold. The results indicate that the silk-collagen scaffold has considerable potential for clinical application.

  7. Robot Arm with Tendon Connector Plate and Linear Actuator

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor); Bridgwater, Lyndon (Inventor); Nguyen, Vienny (Inventor); Millerman, Alexander (Inventor)

    2014-01-01

    A robotic system includes a tendon-driven end effector, a linear actuator, a flexible tendon, and a plate assembly. The linear actuator assembly has a servo motor and a drive mechanism, the latter of which translates linearly with respect to a drive axis of the servo motor in response to output torque from the servo motor. The tendon connects to the end effector and drive mechanism. The plate assembly is disposed between the linear actuator assembly and the tendon-driven end effector and includes first and second plates. The first plate has a first side that defines a boss with a center opening. The second plate defines an accurate through-slot having tendon guide channels. The first plate defines a through passage for the tendon between the center opening and a second side of the first plate. A looped end of the flexible tendon is received within the tendon guide channels.

  8. [Flexor tendon repair: a short story].

    Science.gov (United States)

    Moutet, F; Corcella, D; Forli, A; Mesquida, V

    2014-12-01

    This short story of flexor tendon repair aims to illustrate hesitations and wanderings of this surgery. Obviously tendon repair was very early considered, but it developed and diffused rather lately. It became a routine practice only in 20th century. This was due on the one hand, in Occident, to the Galen's dogmatic interdiction, on the other hand, to the repair difficulties of this paradoxical structure. Actually tendon is made of fibroblasts and collagen (sticky substances), and then its only goal is to move. According to this necessity, whatever the used techniques are, gliding is the final purpose. Technical evolutions are illustrated by historical contributions to flexor tendon surgery of several "giants" of hand surgery. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  9. Shortened stapedius tendon: a rare cause of conductive hearing loss.

    Science.gov (United States)

    Zawawi, F; Varshney, R; Schloss, M D

    2014-01-01

    Anomalies of the stapedius tendon have been reported to cause conductive hearing loss; in theory, such anomalies limit the movement of the stapes. To demonstrate a rare cause of conductive hearing loss resulting from anomaly of the stapedius tendon and to compare the clinical findings of this patient to other stapedius tendon anomalies reported in the literature. Case report of a single case of shortened stapedius tendon and a review of the English literature on stapedius tendon anomalies. This is a case report of a 15-year-old boy with shortened stapedius tendon causing unilateral hearing loss, accompanied by a review of the literature. Contrary to other reported cases, this patient did not have an ossified tendon, but rather an extremely short tendon. The boy regained normal hearing following excision of the stapedius tendon. A shortened stapedius tendon is a very rare diagnosis, yet it should be considered as a possible cause of conductive hearing loss.

  10. Accuracy of MRI technique in measuring tendon cross-sectional area

    DEFF Research Database (Denmark)

    Couppé, Christian; Svensson, R. B.; Elbrønd (Bibs), Vibeke Sødring

    2014-01-01

    , but the accuracy in relation to actual tendon dimensions has never been investigated. The purpose of this study was to compare tendon CSA measured by MRI with that measured in vitro with the mould casting technique. The knee of a horse was MRI-scanned with 1.5 and 3 tesla, and two examiners measured the patellar...... tendon CSA. Thereafter, the patellar tendon of the horse was completely dissected and embedded in an alginate cast. The CSA of the embedded tendon was measured directly by optical imaging of the cast impression. 1.5 tesla grey tendon CSA and 3 tesla grey tendon CSA were 16.5% and 13.2% lower than...... the mould tendon CSA, respectively. Also, 3 tesla tendon CSA, based on the red-green border on the National Institute of Health (NIH) colour scale, was lower than the mould tendon CSA by 2.8%. The typical error between examiners was below 2% for all the measured CSA. The typical error between examiners...

  11. The blood-tendon barrier: identification and characterisation of a novel tissue barrier in tendon blood vessels

    Directory of Open Access Journals (Sweden)

    C Lehner

    2016-05-01

    Full Text Available Tissue barriers function as “gate keepers” between different compartments (usually blood and tissue and are formed by specialised membrane-associated proteins, localising to the apicolateral plasma membrane domain of epithelial and endothelial cells. By sealing the paracellular space, the free diffusion of solutes and molecules across epithelia and endothelia is impeded. Thereby, tissue barriers contribute to the establishment and maintenance of a distinct internal and external environment, which is crucial during organ development and allows maintenance of an organ-specific homeostatic milieu. So far, various epithelial and endothelial tissue barriers have been described, including the blood-brain barrier, the blood-retina barrier, the blood-testis barrier, the blood-placenta barrier, and the cerebrospinal fluid (CSF-brain barrier, which are vital for physiological function and any disturbance of these barriers can result in severe organ damage or even death. Here, we describe the identification of a novel barrier, located in the vascular bed of tendons, which we term the blood-tendon barrier (BTB. By using immunohistochemistry, transmission electron microscopy, and tracer studies we demonstrate the presence of a functional endothelial barrier within tendons restricting the passage of large blood-borne molecules into the surrounding tendon tissue. We further provide in vitro evidence that the BTB potentially contributes to the creation of a distinct internal tissue environment impacting upon the proliferation and differentiation of tendon-resident cells, effects which might be fundamental for the onset of tendon pathologies.

  12. p38 MAPK signaling in postnatal tendon growth and remodeling.

    Directory of Open Access Journals (Sweden)

    Andrew J Schwartz

    Full Text Available Tendon is a dynamic tissue whose structure and function is influenced by mechanical loading, but little is known about the fundamental mechanisms that regulate tendon growth and remodeling in vivo. Data from cultured tendon fibroblasts indicated that the p38 MAPK pathway plays an important role in tendon fibroblast proliferation and collagen synthesis in vitro. To gain greater insight into the mechanisms of tendon growth, and explore the role of p38 MAPK signaling in this process, we tested the hypotheses that inducing plantaris tendon growth through the ablation of the synergist Achilles tendon would result in rapid expansion of a neotendon matrix surrounding the original tendon, and that treatment with the p38 MAPK inhibitor SB203580 would prevent this growth. Rats were treated with vehicle or SB203580, and subjected to synergist ablation by bilateral tenectomy of the Achilles tendon. Changes in histological and biochemical properties of plantaris tendons were analyzed 3, 7, or 28 days after overload, and comparisons were made to non-overloaded animals. By 28 days after overload, tendon mass had increased by 30% compared to non-overloaded samples, and cross-sectional area (CSA increased by around 50%, with most of the change occurring in the neotendon. The expansion in CSA initially occurred through the synthesis of a hyaluronic acid rich matrix that was progressively replaced with mature collagen. Pericytes were present in areas of active tendon growth, but never in the original tendon ECM. Inhibition of p38 MAPK resulted in a profound decrease in IL6 expression, and had a modest effect on the expression of other ECM and cell proliferation genes, but had a negligible impact on overall tendon growth. The combined results from this study provided novel insights into tendon mechanobiology, and suggest that p38 MAPK signaling does not appear to be necessary for tendon growth in vivo.

  13. Glutaraldehyde Cross-Linking of TendonMechanical Effects at the Level of the Tendon Fascicle and Fibril

    DEFF Research Database (Denmark)

    Hansen, P.; Svensson, R.B.; Aagaard, P.

    2009-01-01

    were examined by atomic force microscopy. Peak forces increased from 1379 to 2622 pN while an extended Hertz fit of force-indentation data showed a 24 fold increase in Young's modulus on indentation. The effect of glutaraldehyde cross-linking on the tensile properties of a single collagen fibril......Conclusive insight into the microscopic principles that govern the strength of tendon and related connective tissues is lacking and the importance of collagen cross-linking has not been firmly established. The combined application of whole-tissue mechanical testing and atomic force spectroscopy...... allowed for a detailed characterization of the effect of cross-linking in rat-tail tendon. The cross-link inducing agent glutaraldehyde augmented the tensile strength of tendon fascicles. Stress at failure increased from 8 MPa to 39 MPa. The mechanical effects of glutaraldehyde at the tendon fibril level...

  14. Longitudinal Long-term Magnetic Resonance Imaging and Clinical Follow-up After Single-Row Arthroscopic Rotator Cuff Repair: Clinical Superiority of Structural Tendon Integrity.

    Science.gov (United States)

    Heuberer, Philipp R; Smolen, Daniel; Pauzenberger, Leo; Plachel, Fabian; Salem, Sylvia; Laky, Brenda; Kriegleder, Bernhard; Anderl, Werner

    2017-05-01

    The number of arthroscopic rotator cuff surgeries is consistently increasing. Although generally considered successful, the reported number of retears after rotator cuff repair is substantial. Short-term clinical outcomes are reported to be rarely impaired by tendon retears, whereas to our knowledge, there is no study documenting long-term clinical outcomes and tendon integrity after arthroscopic rotator cuff repair. To investigate longitudinal long-term repair integrity and clinical outcomes after arthroscopic rotator cuff reconstruction. Case series; Level of evidence, 4. Thirty patients who underwent arthroscopic rotator cuff repair with suture anchors for a full-tendon full-thickness tear of the supraspinatus or a partial-tendon full-thickness tear of the infraspinatus were included. Two and 10 years after initial arthroscopic surgery, tendon integrity was analyzed using magnetic resonance imaging (MRI). The University of California, Los Angeles (UCLA) score and Constant score as well as subjective questions regarding satisfaction with the procedure and return to normal activity were used to evaluate short- and long-term outcomes. At the early MRI follow-up, 42% of patients showed a full-thickness rerupture, while 25% had a partial rerupture, and 33% of tendons remained intact. The 10-year MRI follow-up (129 ± 11 months) showed 50% with a total rerupture, while the other half of the tendons were partially reruptured (25%) or intact (25%). The UCLA and Constant scores significantly improved from preoperatively (UCLA total: 50.6% ± 20.2%; Constant total: 44.7 ± 10.5 points) to 2 years (UCLA total: 91.4% ± 16.0% [ P rotator cuff repair showed good clinical long-term results despite a high rate of retears. Nonetheless, intact tendons provided significantly superior clinical long-term outcomes, making the improvement of tendon healing and repair integrity important goals of future research efforts.

  15. Pathophysiology of overuse tendon injury

    International Nuclear Information System (INIS)

    Kannus, P.; Paavola, M.; Paakkala, T.; Parkkari, J.; Jaervinen, T.; Jaervinen, M.

    2002-01-01

    Overuse tendon injury is one of the most common injuries in sports.The etiology as well as the pathophysilogical mechanisms leading to tendinopathy are of crucial medical importance.At the moment intrinsic and extrinsic factors are assumed as mechanisms of overuse tendon injury. Except for the acute, extrinsic trauma, the chronic overuse tendon injury is a multifactorial process. There are many other factors, such as local hypoxia, less of nutrition, impaired metabolism and local inflammatory that may also contribute to the development of tissue damage.The exact interaction of these factors cannot be explained entirely at the moment.Further studies will be necessary in order to get more information. (orig.) [de

  16. Simultaneous bilateral patellar tendon rupture

    Directory of Open Access Journals (Sweden)

    Diogo Lino Moura

    Full Text Available ABSTRACT Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  17. Rotator cuff tendon connections with the rotator cable.

    Science.gov (United States)

    Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo

    2017-07-01

    The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.

  18. Injury to the Infrapatellar Branch of the Saphenous Nerve during ACL Reconstruction with Hamstring Tendon Autograft: A Comparison between Oblique and Vertical Incisions

    Directory of Open Access Journals (Sweden)

    Hamid Mousavi

    2018-01-01

    Full Text Available Background: Injury to the infrapatellar branch of the saphenous nerve (IPBSN is common after arthroscopic ACLreconstruction with hamstring tendon autograft, as reported in up to 88% of the cases. Due to close relationshipbetween the IPBSN with pes anserine tendons insertion skin incision may sever IPBSN while harvesting gracillis andsemitendinous tendons. As the IPBSN course at the anterior of knee is oblique, we hypothesized a parallel skin incisionwith nerve passage may decrease nerve injury.Methods: Vertical and oblique incisions were compared in 79 patients in this clinical trial. The sensory loss area andpatients’ complain of numbness were measured at 2 and 8 weeks as well as 6 months after surgery.Results: Both the sensory loss area and patients’ complain of numbness decreased significantly in the oblique incisiongroup (P

  19. Uncovering the cellular and molecular changes in tendon stem/progenitor cells attributed to tendon aging and degeneration.

    Science.gov (United States)

    Kohler, Julia; Popov, Cvetan; Klotz, Barbara; Alberton, Paolo; Prall, Wolf Christian; Haasters, Florian; Müller-Deubert, Sigrid; Ebert, Regina; Klein-Hitpass, Ludger; Jakob, Franz; Schieker, Matthias; Docheva, Denitsa

    2013-12-01

    Although the link between altered stem cell properties and tissue aging has been recognized, the molecular and cellular processes of tendon aging have not been elucidated. As tendons contain stem/progenitor cells (TSPC), we investigated whether the molecular and cellular attributes of TSPC alter during tendon aging and degeneration. Comparing TSPC derived from young/healthy (Y-TSPC) and aged/degenerated human Achilles tendon biopsies (A-TSPC), we observed that A-TSPC exhibit a profound self-renewal and clonogenic deficits, while their multipotency was still retained. Senescence analysis showed a premature entry into senescence of the A-TSPC, a finding accompanied by an upregulation of p16(INK4A). To identify age-related molecular factors, we performed microarray and gene ontology analyses. These analyses revealed an intriguing transcriptomal shift in A-TSPC, where the most differentially expressed probesets encode for genes regulating cell adhesion, migration, and actin cytoskeleton. Time-lapse analysis showed that A-TSPC exhibit decelerated motion and delayed wound closure concomitant to a higher actin stress fiber content and a slower turnover of actin filaments. Lastly, based on the expression analyses of microarray candidates, we suggest that dysregulated cell-matrix interactions and the ROCK kinase pathway might be key players in TSPC aging. Taken together, we propose that during tendon aging and degeneration, the TSPC pool is becoming exhausted in terms of size and functional fitness. Thus, our study provides the first fundamental basis for further exploration into the molecular mechanisms behind tendon aging and degeneration as well as for the selection of novel tendon-specific therapeutical targets. © 2013 The Authors. Aging Cell published by the Anatomical Society and John Wiley & Sons Ltd.

  20. Measurement of stress strain and vibrational properties of tendons

    Science.gov (United States)

    Revel, Gian Marco; Scalise, Alessandro; Scalise, Lorenzo

    2003-08-01

    The authors present a new non-intrusive experimental procedure based on laser techniques for the measurement of mechanical properties of tendons. The procedure is based on the measurement of the first resonance frequency of the tendon by laser Doppler vibrometry during in vitro tensile experiments, with the final aim of establishing a measurement procedure to perform the mechanical characterization of tendons by extracting parameters such as the resonance frequency, also achievable during in vivo investigation. The experimental procedure is reported, taking into account the need to simulate the physiological conditions of the Achilles tendon, and the measurement technique used for the non-invasive determination of tendon cross-sectional area during tensile vibration tests at different load levels is described. The test procedure is based on a tensile machine, which measures longitudinal tendons undergoing controlled load conditions. Cross-sectional area is measured using a new non-contact procedure for the measurement of tendon perimeter (repeatability of 99% and accuracy of 2%). For each loading condition, vibration resonance frequency and damping, cross-sectional area and tensile force are measured, allowing thus a mechanical characterization of the tendon. Tendon stress-strain curves are reported. Stress-strain curves have been correlated to the first vibration resonance frequency and damping of the tendon measured using a single-point laser Doppler vibrometer. Moreover, experimental results have been compared with a theoretical model of a vibrating cord showing discrepancies. In vitro tests are reported, demonstrating the validity of the method for the comparison of different aged rabbit tendons.

  1. MRI in flexor tendon rupture after collagenase injection

    International Nuclear Information System (INIS)

    Khurana, Shruti; Wadhwa, Vibhor; Chhabra, Avneesh; Amirlak, Bardia

    2017-01-01

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  2. MRI in flexor tendon rupture after collagenase injection

    Energy Technology Data Exchange (ETDEWEB)

    Khurana, Shruti [Lady Hardinge Medical College, New Delhi (India); Wadhwa, Vibhor [University of Arkansas for Medical Sciences, Little Rock, AR (United States); Chhabra, Avneesh [UT Southwestern Medical Center, Dallas, TX (United States); Johns Hopkins University, Baltimore, MD (United States); Amirlak, Bardia [UT Southwestern Medical Center, Dallas, TX (United States)

    2017-02-15

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  3. Nonoperative, dynamic treatment of acute achilles tendon rupture

    DEFF Research Database (Denmark)

    Barfod, Kristoffer Weisskirchner; Bencke, Jesper; Lauridsen, Hanne Bloch

    2015-01-01

    Acute Achilles tendon rupture alters the biomechanical properties of the plantar flexor muscle-tendon complex that can affect functional performance and the risk of repeat injury. The purpose of the present study was to compare the biomechanical properties of the plantar flexor muscle-tendon comp......Acute Achilles tendon rupture alters the biomechanical properties of the plantar flexor muscle-tendon complex that can affect functional performance and the risk of repeat injury. The purpose of the present study was to compare the biomechanical properties of the plantar flexor muscle...... in the terminal part of dorsiflexion was found in the non-weightbearing group. The altered stiffness and strength in the affected limb could affect the coordination of gait and running....

  4. Effect of cyclic training model on terminal structure of rabbit Achilles tendon: an experimental study

    Directory of Open Access Journals (Sweden)

    Chang-lin HUANG

    2012-05-01

    group at the early stage, but there was an increase at the late stage of the training (6 weeks later, however the score values were lower than those in the jumping group and running group. These changes in score were originated mainly from pathological changes in the paratenon and tidemark. Conclusions  Jumping training could lead to severe injury to the fiber tissue and fibrocartilage, while running training might result in severe injury to Achilles tendon insertion structure and lighter injury to the fibrocartilage part. Cyclic training model provides suffcient time for repair and reconstruction of Achilles tendon insertion structure, and decrease the severity of the injury to Achilles tendon insertion region. Therefore, use of cyclic training could not only effectively prevent training-based enthesiopathy, but also accelerate the remodeling of the tissue in the insertion region, thus strengthen the repair ability of Achilles tendon against injury.

  5. Region-specific mechanical properties of the human patella tendon

    DEFF Research Database (Denmark)

    Haraldsson, B T; Aagaard, P; Krogsgaard, M

    2004-01-01

    The present study investigated the mechanical properties of tendon fascicles from the anterior and posterior human patellar tendon. Collagen fascicles from the anterior and posterior human patellar tendon in healthy young men (mean +/- SD, 29.0 +/- 4.6 yr, n = 6) were tested in a mechanical rig...... portion of the tendon, indicating region-specific material properties....

  6. Collateral ligament reconstruction of the chronic thumb injury with bio-tenodesis screw fixation

    DEFF Research Database (Denmark)

    Gvozdenovic, Robert; Boeckstyns, Michel

    2014-01-01

    We describe a new technique for the reconstruction of chronic lesions of the collateral ligaments of the metacarpophalangeal ligaments of the thumb, using a Bio-Tenodesis screw for the fixation of a tendon graft in a triangular manner with proximal apex and allowing early mobilization, starting 2...

  7. Correlation between hindfoot joint three-dimensional kinematics and the changes of the medial arch angle in stage II posterior tibial tendon dysfunction flatfoot.

    Science.gov (United States)

    Zhang, Yi-Jun; Xu, Jian; Wang, Yue; Lin, Xiang-Jin; Ma, Xin

    2015-02-01

    The aim of this study was to explore the correlation between the kinematics of the hindfoot joint and the medial arch angle change in stage II posterior tibial tendon dysfunction flatfoot three-dimensionally under loading. Computed tomography (CT) scans of 12 healthy feet and 12 feet with stage II posterior tibial tendon dysfunction flatfoot were taken both in non- and full-body-weight-bearing condition. The CT images of the hindfoot bones were reconstructed into three-dimensional models with Mimics and Geomagic reverse engineering software. The three-dimensional changes of the hindfoot joint were calculated to determine their correlation to the medial longitudinal arch angle. The medial arch angle change was larger in stage II posterior tibial tendon dysfunction flatfoot compared to that in healthy foot under loading. The rotation and translation of the talocalcaneal joint, the talonavicular joint and the calcanocuboid joint had little influence on the change of the medial arch angle in healthy foot. However, the eversion of the talocalcaneal joint, the proximal translation of the calcaneus relative to the talus and the dorsiflexion of talonavicular joint could increase the medial arch angle in stage II posterior tibial tendon dysfunction flatfoot under loading. Joint instability occurred in patients with stage II posterior tibial tendon dysfunction flatfoot under loading. Limitation of over movement of the talocalcaneal joint and the talonavicular joint may help correct the medial longitudinal arch in stage II posterior tibial tendon dysfunction flatfoot. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Nanoparticles for tendon healing and regeneration: literature review.

    Directory of Open Access Journals (Sweden)

    Paolo Domenico Parchi

    2016-08-01

    Full Text Available Tendon injuries are commonly met in the emergency department. Unfortunately, tendon tissue has limited regeneration potential and usually the consequent formation of scar tissue causes inferior mechanical properties Nanoparticles could be used in different way to improve tendon healing and regeneration, ranging from scaffolds manufacturing (increasing the strength and endurance or anti-adhesions, anti-microbial and anti-inflammatory properties to gene therapy. This paper aims to summarize the most relevant studies showing the potential application of nanoparticles for tendon tissue regeneration

  9. Reproducibility and clinical utility of tendon palpation to detect patellar tendinopathy in young basketball players. Victorian Institute of Sport tendon study group.

    Science.gov (United States)

    Cook, J L; Khan, K M; Kiss, Z S; Purdam, C R; Griffiths, L

    2001-02-01

    Palpation is an important clinical test for jumper's knee. To (a) test the reproducibility of palpation tenderness, (b) evaluate the sensitivity and specificity of palpation in subjects with clinical symptoms of jumper's knee, and (c) determine whether tenderness to palpation may serve as a useful screening test for patellar tendinopathy. The yardstick for diagnosis of patellar tendinopathy was ultrasonographic abnormality. In 326 junior symptomatic and asymptomatic athletes' tendons, palpation was performed by a single examiner before ultrasonographic examination by a certified ultrasound radiologist. In 58 tendons, palpation was performed twice to test reliability. Tenderness to palpation was scored on a scale from 0 to 3 where 0 represented no pain, and 1, 2, and 3 represented mild, moderate, and severe tenderness respectively. Patellar tendon palpation was a reliable examination for a single examiner (Pearson r = 0.82). In symptomatic tendons, the positive predictive value of palpation was 68%. As a screening examination in asymptomatic subjects, the positive predictive value of tendon palpation was 36-38%. Moderate and severe palpation tenderness were better predictors of ultrasonographic tendon pathology than absent or mild tenderness (ppatellar tendinopathy in a preparticipation examination. In symptomatic tendons, palpation is a moderately sensitive but not specific test. Mild tenderness in the patellar tendons in asymptomatic jumping athletes should be considered normal.

  10. Science to Practice: Quantitative US Elastography Can Be Used to Quantify Mechanical and Histologic Tendon Healing in a Rabbit Model of Achilles Tendon Transection.

    Science.gov (United States)

    Lee, Kenneth S; Martin, Jack; Thelen, Darryl

    2017-05-01

    Compression-based ultrasonographic (US) elastography is associated with time-dependent mechanical and histologic changes of the healing tendon in a transected rabbit model of the Achilles tendon. This finding will lead to continued development of quantitative US, which can be used to objectively assess a diseased or healing tendon. With advances in the method used, clinical translation of tendon elastography may enable clinicians to diagnose tendon damage and track healing, which should improve both treatment and outcome.

  11. Tendon injury and repair - A perspective on the basic mechanisms of tendon disease and future clinical therapy

    NARCIS (Netherlands)

    Snedeker, J.G.; Foolen, J.

    2017-01-01

    Tendon is an intricately organized connective tissue that efficiently transfers muscle force to the bony skeleton. Its structure, function, and physiology reflect the extreme, repetitive mechanical stresses that tendon tissues bear. These mechanical demands also lie beneath high clinical rates of

  12. Treatment with vacuum-assisted closure and cryo-preserved homologous de-epidermalised dermis of complex traumas to the lower limbs with loss of substance, and bones and tendons exposure.

    Science.gov (United States)

    Brandi, C; Grimaldi, L; Nisi, G; Silvestri, A; Brafa, A; Calabrò, M; D'Aniello, C

    2008-12-01

    Lower-limb injuries with loss of tissue and exposure of bones and tendons are an increasing problem. The condition of the wound locally and the patient in general does not always allow immediate and adequate coverage of the structures exposed by the trauma. Therefore, new therapeutic solutions are needed. A reduction in the time that bones and tendons are exposed is essential to achieve complete healing of bone fractures, with reduced risks of infection and less disabling outcomes. The effectiveness of vacuum-assisted closure (VAC) therapy in supporting wound healing and of cryopreserved homologous de-epidermalised dermis (DED) in providing an effective template for re-epithelialisation has been previously reported. We carried out a study to evaluate the effectiveness of the synergistic and combined use of the two methodologies. Eighteen patients with traumatic loss of tissue in the lower limbs, involving exposure of bone and tendon structures, were enrolled in the study. All participants had local, general contraindications to first-instance reconstructions, or both. All patients received a combination of VAC therapy and DED implants. Granulation tissue was obtained in all wounds, with complete coverage of exposed structures. No infections were detected in the cohort, and all patients were prepared for further necessary reconstructive treatments. In our experience, the combination of VAC therapy and DED could, in selected cases, constitute an effective treatment for complex lower limb traumatic injuries with bone and tendon exposure.

  13. MRI and gross anatomy of the iliopsoas tendon complex

    International Nuclear Information System (INIS)

    Polster, Joshua M.; Lee, Ho; Klika, Alison; Barsoum, Wael; Drake, Richard; Elgabaly, Mohamed

    2008-01-01

    The objective was to explain the anatomic basis of a longitudinal cleft of increased signal in the iliopsoas tendon seen on hip MR arthrograms. A prospective review of 20 MR hip arthrograms was performed using standard and fat-suppressed T1-weighted images to establish whether or not the cleft was composed of fatty tissue and to define the anatomy of the iliopsoas tendon complex. Three cadaver dissections of the hip region were then performed for anatomic correlation. Fourteen out of 20 MR hip arthrograms demonstrated a longitudinal cleft of increased T1 signal adjacent to the iliopsoas tendon, which suppressed on frequency selective fat-suppressed images, indicating fatty composition. Gross anatomic correlation demonstrated this fatty cleft to represent a fascial plane adjacent to the iliopsoas tendon, in one case separating the iliopsoas tendon medially from a thin intramuscular tendon within the lateral portion of the iliacus muscle. Also noted was a direct muscular insertion of the lateral portion of the iliacus muscle onto the anterior portion of the proximal femoral diaphysis in all 3 cadavers. The anatomy of the iliopsoas tendon complex is more complicated than typically illustrated and includes the iliopsoas tendon itself attaching to the lesser trochanter, the lateral portion of the iliacus muscle attaching directly upon the anterior portion of the proximal femoral diaphysis, and a thin intramuscular tendon within this lateral iliacus muscle that is separated from the iliopsoas tendon by a cleft of fatty fascia that accounts for the MRI findings of a cleft of increased T1 signal. (orig.)

  14. The 'bridging sign', a MR finding for combined full-thickness tears of the subscapularis tendon and the supraspinatus tendon

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jin Young [Dept. of Radiology, Saint Paul' s Hospital, The Catholic Univ. of Korea, Seoul (Korea, Republic of); Yoon, Young Cheol; Cha, Dong Ik [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan Univ, School of Medicine, Seoul (Korea, Republic of)], e-mail: ycyoon@skku.edu; Yoo, Jae-Chul [Dept. of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of); Jung, Jee Young [Dept. of Radiology, School of Medicine, Chung-Ang Univ., Seoul (Korea, Republic of)

    2013-02-15

    Background: In daily practice, we discovered one of the secondary magnetic resonance (MR) findings of the subscapularis (SSC) tendon tear, the 'bridging sign', which has not been previously described. Purpose: To describe the 'bridging sign' on shoulder MR imaging and its radiological and clinical significance in patients with SSC tendon tear. Material and Methods: Twenty-nine patients who had undergone shoulder arthroscopy and had full-thickness tear of the subscapularis tendon were enrolled. The medical records of the 29 patients were retrospectively reviewed for the duration of shoulder pain, rotator cuff tears, and associated arthroscopic findings: biceps tendon abnormality and superior glenoid labral tear. Then, preoperative shoulder MR images were retrospectively reviewed for the presence or absence of the 'bridging sign' and associated MR findings: periarticular fluid and fatty atrophy of the supraspinatus and subscapularis muscles. The type of rotator cuff tear associated with the 'bridging sign' was assessed and the sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of a certain type of rotator cuff tear were calculated. Associated arthroscopic and MR findings and mean duration of the shoulder pain between the patients with and without the 'bridging sign' were compared. Results: The 'bridging sign' was seen in 17 of 29 patients and corresponded to a complex of the torn and superomedially retracted subscapularis tendon, coracohumeral ligament, and superior glenohumeral ligament, adhered to the anterior margin of the torn supraspinatus (SSP) tendon on arthroscopy. All patients with the 'bridging sign' had combined full-thickness tear (FTT) of the cranial 1/2 portion of the subscapularis tendon and anterior 1/2 portion of the SSP tendon. The sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of combined FTTs of

  15. Regional strain variations in the human patellar tendon.

    Science.gov (United States)

    Pearson, Stephen J; Ritchings, Tim; Mohamed, Azlan S A

    2014-07-01

    Characteristics of localized tendon strain in vivo are largely unknown. The present study examines local tendon strain between the deep, middle, and surface structures at the proximal and distal aspects of the patellar tendon during ramped isometric contractions. Male subjects (age 28.0 ± 6.3 yr) were examined for patellar tendon excursion (anterior, midsection, and posterior) during ramped isometric voluntary contractions using real-time B-mode ultrasonography and dynamometry. Regional tendon excursion measurements were compared using an automated pixel tracking method. Strain was determined from the tendon delta length normalized to initial/resting segment length. Strain increased from 10% to 100% of force for all regions. Significantly greater mean strain was seen for the anterior proximal region compared to the posterior and mid layer of the tendon (7.5% ± 1.1% vs 3.7% ± 0.5% vs 5.5% ± 1.0%; P < 0.05). Similarly, the distal posterior region showed greater mean strain compared to the mid and anterior regions (7.9% ± 0.6% vs 5.0% ± 0.6% vs 5.4% ± 0.6%; P < 0.05). Relative changes in strain differences from 50% to 100% of force for the proximal region were greatest for the anterior to midline regions (4.6% ± 0.6% and 5.6% ± 0.6%, respectively) and those for the distal region were also greatest for the anterior to midline regions (4.4% ± 0.2% and 5.3% ± 0.2%, respectively). The largest mean strain for the proximal region was at the anterior layer (7.5% ± 1.1%) and that for the distal tendon region was at the posterior layer (7.9% ± 0.9%). This study shows significant regional differences in strain during ramped isometric contractions for the patellar tendon. Lower proximal strains in the posterior tendon compared to the anterior region may be associated with the suggestion of "stress shielding" as an etiological factor in insertional tendinopathy.

  16. Torque Control of Underactuated Tendon-driven Robotic Fingers

    Science.gov (United States)

    Abdallah, Muhammad E. (Inventor); Ihrke, Chris A. (Inventor); Reiland, Matthew J. (Inventor); Wampler, Charles W. (Inventor); Diftler, Myron A. (Inventor); Platt, Robert (Inventor); Bridgwater, Lyndon (Inventor)

    2013-01-01

    A robotic system includes a robot having a total number of degrees of freedom (DOF) equal to at least n, an underactuated tendon-driven finger driven by n tendons and n DOF, the finger having at least two joints, being characterized by an asymmetrical joint radius in one embodiment. A controller is in communication with the robot, and controls actuation of the tendon-driven finger using force control. Operating the finger with force control on the tendons, rather than position control, eliminates the unconstrained slack-space that would have otherwise existed. The controller may utilize the asymmetrical joint radii to independently command joint torques. A method of controlling the finger includes commanding either independent or parameterized joint torques to the controller to actuate the fingers via force control on the tendons.

  17. Successful anterior cruciate ligament reconstruction and meniscal repair in osteogenesis imperfecta.

    Science.gov (United States)

    Park, Jae-Young; Cho, Tae-Joon; Lee, Myung Chul; Han, Hyuk-Soo

    2018-03-20

    A case of anterior cruciate ligament (ACL) reconstruction with meniscal repair in an osteogenesis imperfecta patient is reported. A 24-year-old female with osteogenesis imperfecta type 1a suffered from a valgus extension injury resulting in tear of ACL and medial meniscus. She underwent an arthroscopic-assisted ACL reconstruction and medial meniscus repair. Meniscal tear at the menisco-capsular junction of the posterior horn of medial meniscus was repaired with three absorbable sutures via inside-out technique. ACL reconstruction was then performed with a bone-patellar tendon-bone allograft. The patient was followed up for 1 year with intact ACL grafts and healed medial meniscus. This case report showed that successful ACL reconstruction and meniscal repair is possible in an osteogenesis imperfecta patient.Level of evidence V.

  18. Smart Tendon Actuated Flexible Actuator

    Directory of Open Access Journals (Sweden)

    Md. Masum Billah

    2015-01-01

    Full Text Available We investigate the kinematic feasibility of a tendon-based flexible parallel platform actuator. Much of the research on tendon-driven Stewart platforms is devoted either to the completely restrained positioning mechanism (CRPM or to one particular type of the incompletely restrained positioning mechanism (IRPM where the external force is provided by the gravitational pull on the platform such as in cable-suspended Stewart platforms. An IRPM-based platform is proposed which uses the external force provided by a compliant member. The compliant central column allows the configuration to achieve n DOFs with n tendons. In particular, this investigation focuses on the angular deflection of the upper platform with respect to the lower platform. The application here is aimed at developing a linkable module that can be connected to one another so as to form a “snake robot” of sorts. Since locomotion takes precedence over positioning in this application, a 3-DOF Stewart platform is adopted. For an arbitrary angular displace of the end-effector, the corresponding length of each tendon can be determined through inverse kinematics. Mathematical singularities are investigated using the traditional analytical method of defining the Jacobian.

  19. Tendon Reattachment to Bone in an Ovine Tendon Defect Model of Retraction Using Allogenic and Xenogenic Demineralised Bone Matrix Incorporated with Mesenchymal Stem Cells.

    Directory of Open Access Journals (Sweden)

    Tanujan Thangarajah

    Full Text Available Tendon-bone healing following rotator cuff repairs is mainly impaired by poor tissue quality. Demineralised bone matrix promotes healing of the tendon-bone interface but its role in the treatment of tendon tears with retraction has not been investigated. We hypothesized that cortical demineralised bone matrix used with minimally manipulated mesenchymal stem cells will result in improved function and restoration of the tendon-bone interface with no difference between xenogenic and allogenic scaffolds.In an ovine model, the patellar tendon was detached from the tibial tuberosity and a complete distal tendon transverse defect measuring 1 cm was created. Suture anchors were used to reattach the tendon and xenogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5, or allogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5 were used to bridge the defect. Graft incorporation into the tendon and its effect on regeneration of the enthesis was assessed using histomorphometry. Force plate analysis was used to assess functional recovery.Compared to the xenograft, the allograft was associated with significantly higher functional weight bearing at 6 (P = 0.047, 9 (P = 0.028, and 12 weeks (P = 0.009. In the allogenic group this was accompanied by greater remodeling of the demineralised bone matrix into tendon-like tissue in the region of the defect (p = 0.015, and a more direct type of enthesis characterized by significantly more fibrocartilage (p = 0.039. No failures of tendon-bone healing were noted in either group.Demineralised bone matrix used with minimally manipulated mesenchymal stem cells promotes healing of the tendon-bone interface in an ovine model of acute tendon retraction, with superior mechanical and histological results associated with use of an allograft.

  20. Partial tear of the quadriceps tendon in a child

    International Nuclear Information System (INIS)

    Khanna, Geetika; El-Khoury, George

    2008-01-01

    We present a case of partial rupture of the quadriceps tendon in an 8-year-old girl. This is one of the youngest patients reported with a quadriceps tendon rupture, an entity seen predominantly in middle-aged people. The strength of the muscle tendon unit in a child makes tendon injuries extremely unusual as compared to apophyseal avulsions. The MR imaging findings of this unusual pediatric injury are illustrated. (orig.)

  1. Quantitative US Elastography Can Be Used to Quantify Mechanical and Histologic Tendon Healing in a Rabbit Model of Achilles Tendon Transection.

    Science.gov (United States)

    Yamamoto, Yohei; Yamaguchi, Satoshi; Sasho, Takahisa; Fukawa, Taisuke; Akatsu, Yorikazu; Akagi, Ryuichiro; Yamaguchi, Tadashi; Takahashi, Kenji; Nagashima, Kengo; Takahashi, Kazuhisa

    2017-05-01

    Purpose To determine the time-dependent change in strain ratios (SRs) at the healing site of an Achilles tendon rupture in a rabbit model of tendon transection and to assess the correlation between SRs and the mechanical and histologic properties of the healing tissue. Materials and Methods Experimental methods were approved by the institutional animal care and use committee. The Achilles tendons of 24 New Zealand white rabbits (48 limbs) were surgically transected. The SRs of Achilles tendons were calculated by using compression-based quantitative ultrasonographic elastography measurements obtained 2, 4, 8, and 12 weeks after transection. After in vivo elastography, the left Achilles tendon was harvested for mechanical testing of ultimate load, ultimate stress, elastic modulus, and linear stiffness, and the right tendons were harvested for tissue histologic analysis with the Bonar scale. Time-dependent changes in SRs, mechanical parameters, and Bonar scale scores were evaluated by using repeated-measures analysis of variance. The correlation between SRs and each measured variable was evaluated by using the Spearman rank correlation coefficient. Results Mean SRs and Bonar scale values decreased as a function of time after transection, whereas mechanical parameters increased (P tendon. © RSNA, 2017 Online supplemental material is available for this article.

  2. Editorial Commentary: All-Inside Anterior Cruciate Ligament Reconstruction Can Afford Satisfactory Clinical Outcome and Functional Stability.

    Science.gov (United States)

    Yoshiya, Shinichi

    2016-02-01

    Anatomic all-inside anterior cruciate ligament reconstruction using the autogenous semitendinosus tendon graft can afford satisfactory outcomes, achieving significant postoperative improvement in all clinical parameters. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. Hyperuricemic PRP in Tendon Cells

    Directory of Open Access Journals (Sweden)

    I. Andia

    2014-01-01

    Full Text Available Platelet-rich plasma (PRP is injected within tendons to stimulate healing. Metabolic alterations such as the metabolic syndrome, diabetes, or hyperuricemia could hinder the therapeutic effect of PRP. We hypothesise that tendon cells sense high levels of uric acid and this could modify their response to PRP. Tendon cells were treated with allogeneic PRPs for 96 hours. Hyperuricemic PRP did not hinder the proliferative actions of PRP. The gene expression pattern of inflammatory molecules in response to PRP showed absence of IL-1b and COX1 and modest expression of IL6, IL8, COX2, and TGF-b1. IL8 and IL6 proteins were secreted by tendon cells treated with PRP. The synthesis of IL6 and IL8 proteins induced by PRP is decreased significantly in the presence of hyperuricemia (P = 0.017 and P = 0.012, resp.. Concerning extracellular matrix, PRP-treated tendon cells displayed high type-1 collagen, moderate type-3 collagen, decorin, and hyaluronan synthase-2 expression and modest expression of scleraxis. Hyperuricemia modified the expression pattern of extracellular matrix proteins, upregulating COL1 (P = 0.036 and COMP (P = 0.012 and downregulating HAS2 (P = 0.012. Positive correlations between TGF-b1 and type-1 collagen (R = 0.905, P = 0.002 and aggrecan (R = 0.833, P = 0.010 and negative correlations between TGF-b1 and IL6 synthesis (R = −0.857, P = 0.007 and COX2 (R = −0.810, P = 0.015 were found.

  4. Effectiveness of xenogenous-based bovine-derived platelet gel embedded within a three-dimensional collagen implant on the healing and regeneration of the Achilles tendon defect in rabbits.

    Science.gov (United States)

    Moshiri, Ali; Oryan, Ahmad; Meimandi-Parizi, Abdolhamid; Koohi-Hosseinabadi, Omid

    2014-08-01

    Tissue engineering is an option in reconstructing large tendon defects and managing their healing and regeneration. We designed and produced a novel xenogeneic-based bovine platelet, embedded it within a tissue-engineered collagen implant (CI) and applied it in an experimentally induced large tendon defect model in rabbits to test whether bovine platelets could stimulate tendon healing and regeneration in vivo. One hundred twenty rabbits were randomly divided into two experimental and pilot groups. In all the animals, the left Achilles tendon was surgically excised and the tendon edges were aligned by Kessler suture. Each group was then divided into three groups of control (no implant), treated with CI and treated with collagen-platelet implant. The pilot groups were euthanized at 10, 15, 30 and 40 days post-injury (DPI), and their gross and histologic characteristics were evaluated to study host-graft interaction mechanism. To study the tendon healing and its outcome, the experimental animals were tested during the experiment using hematologic, ultrasonographic and various methods of clinical examinations and then euthanized at 60 DPI and their tendons were evaluated by gross pathologic, histopathologic, scanning electron microscopic, biophysical and biochemical methods. Bovine platelets embedded within a CI increased inflammation at short term while it increased the rate of implant absorption and matrix replacement compared with the controls and CI alone. Treatment also significantly increased diameter, density, amount, alignment and differentiation of the collagen fibrils and fibers and approximated the water uptake and delivery behavior of the healing tendons to normal contralaterals (p tendons and reduced peritendinous adhesion, muscle fibrosis and atrophy, and therefore, it improved the clinical scores and physical activity related to the injured limb when compared with the controls (p Achilles tendon in rabbit. This strategy may be a valuable option in the

  5. Tendon shift in hallux valgus: observations at MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Eustace, S. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Williamson, D. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States); Wilson, M. [Department of Orthopedics, Brigham and Womens Hospital, Boston, Massachusetts (United States); O`Byrne, J. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Bussolari, L. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States); Thomas, M. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States); Stephens, M. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Stack, J. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Weissman, B. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States)

    1996-08-01

    Objective. This study was undertaken to demonstrate a shift in tendon alignment at the first metatarsophalangeal joint in patients with hallux valgus by means of magnetic resonance imaging. Design. Ten normal feet and 20 feet with the hallux valgus deformity conforming to conventional clinical and radiographic criteria were prospectively studied using magnetic resonance imaging. Correlation was made between tendon position at the first metatarsophalangeal joint and the severity of the hallux valgus deformity. Results. There is a significant shift in tendon position at the first metatarsophalangeal joint of patients with hallux valgus. The insertion of the abductor hallucis tendon is markedly plantarward and the flexor and extensor tendons bowstring at the first metatarsophalangeal joint compared with patients without the deformity. The severity of the tendon shift correlates with the hallux valgus angle and clinical severity of the hallux valgus deformity in each case. Conclusion. Patients with hallux valgus have a significant tendon shift at the first metatarsophalangeal joint which appears to contribute to development of the deformity. (orig.). With 4 figs., 1 tab.

  6. Tendon shift in hallux valgus: observations at MR imaging

    International Nuclear Information System (INIS)

    Eustace, S.; Williamson, D.; Wilson, M.; O'Byrne, J.; Bussolari, L.; Thomas, M.; Stephens, M.; Stack, J.; Weissman, B.

    1996-01-01

    Objective. This study was undertaken to demonstrate a shift in tendon alignment at the first metatarsophalangeal joint in patients with hallux valgus by means of magnetic resonance imaging. Design. Ten normal feet and 20 feet with the hallux valgus deformity conforming to conventional clinical and radiographic criteria were prospectively studied using magnetic resonance imaging. Correlation was made between tendon position at the first metatarsophalangeal joint and the severity of the hallux valgus deformity. Results. There is a significant shift in tendon position at the first metatarsophalangeal joint of patients with hallux valgus. The insertion of the abductor hallucis tendon is markedly plantarward and the flexor and extensor tendons bowstring at the first metatarsophalangeal joint compared with patients without the deformity. The severity of the tendon shift correlates with the hallux valgus angle and clinical severity of the hallux valgus deformity in each case. Conclusion. Patients with hallux valgus have a significant tendon shift at the first metatarsophalangeal joint which appears to contribute to development of the deformity. (orig.). With 4 figs., 1 tab

  7. Effects of gamma irradiation on the biomechanical properties of peroneus tendons

    Directory of Open Access Journals (Sweden)

    Aguila CM

    2016-09-01

    Full Text Available Christopher M Aguila,1 Gaëtan J-R Delcroix,2–5 David N Kaimrajh,6 Edward L Milne,6 H Thomas Temple,5,7 Loren L Latta2,6 1Department of Biological Sciences, Florida International University, Miami, FL, USA; 2Department of Orthopaedics, Miller School of Medicine, University of Miami, Miami, FL, USA; 3Research Service & Geriatric Research, Education, and Clinical Center, Bruce W. Carter Veterans Affairs Medical Center, Miami, FL, USA; 4Interdisciplinary Stem Cell Institute, University of Miami, Miami, FL, USA; 5Vivex Biomedical Inc., Marietta, GA, USA; 6Max Biedermann Institute for Biomechanics, Miami Beach, FL, USA; 7Translational Research and Economic Development, Nova Southeastern University, Fort-Lauderdale, FL, USA Purpose: This study was designed to investigate the biomechanical properties of nonirradiated (NI and irradiated (IR peroneus tendons to determine if they would be suitable allografts, in regards to biomechanical properties, for anterior cruciate ligament reconstruction after a dose of 1.5–2.5 Mrad.Methods: Seven pairs of peroneus longus (PL and ten pairs of peroneus brevis (PB tendons were procured from human cadavers. The diameter of each allograft was measured. The left side of each allograft was IR at 1.5–2.5 Mrad, whereas the right side was kept aseptic and NI. The allografts were thawed, kept wet with saline, and attached in a single-strand fashion to custom freeze grips using liquid nitrogen. A preload of 10 N was then applied and, after it had reached steady state, the allografts were pulled at 4 cm/sec. The parameters recorded were the displacement and force.Results: The elongation at the peak load was 10.3±2.3 mm for the PB NI side and 13.5±3.3 mm for the PB IR side. The elongation at the peak load was 17.4±5.3 mm for the PL NI side and 16.3±2.0 mm for the PL IR side. For PL, the ultimate load was 2,091.6±148.7 N for NI and 2,122.8±380.0 N for IR. The ultimate load for the PB tendons was 1,485.7±209.3 N for

  8. Reconstrucción y restauración de la rotura aguda del tendón rotuliano con aumento del tendon semitendinoso preservando su inserción distal. Reporte de un caso.[Reconstruction and repair of acute patellar tendon ruptures with semitendinosus autograft].

    Directory of Open Access Journals (Sweden)

    Víctor Andres Ciccarello

    2016-11-01

    Full Text Available Se presenta un caso de ruptura aguda de tendon rotuliano con mala calidad de tejido remanente , en la que se realiza una tecnica de restauración y aumentación con injerto del tendon semitendinoso ipsilateral , preservando su inseríón distal.

  9. Tendon material properties vary and are interdependent among turkey hindlimb muscles.

    Science.gov (United States)

    Matson, Andrew; Konow, Nicolai; Miller, Samuel; Konow, Pernille P; Roberts, Thomas J

    2012-10-15

    The material properties of a tendon affect its ability to store and return elastic energy, resist damage, provide mechanical feedback and amplify or attenuate muscle power. While the structural properties of a tendon are known to respond to a variety of stimuli, the extent to which material properties vary among individual muscles remains unclear. We studied the tendons of six different muscles in the hindlimb of Eastern wild turkeys to determine whether there was variation in elastic modulus, ultimate tensile strength and resilience. A hydraulic testing machine was used to measure tendon force during quasi-static lengthening, and a stress-strain curve was constructed. There was substantial variation in tendon material properties among different muscles. Average elastic modulus differed significantly between some tendons, and values for the six different tendons varied nearly twofold, from 829±140 to 1479±106 MPa. Tendons were stretched to failure, and the stress at failure, or ultimate tensile stress, was taken as a lower-limit estimate of tendon strength. Breaking tests for four of the tendons revealed significant variation in ultimate tensile stress, ranging from 66.83±14.34 to 112.37±9.39 MPa. Resilience, or the fraction of energy returned in cyclic length changes was generally high, and one of the four tendons tested was significantly different in resilience from the other tendons (range: 90.65±0.83 to 94.02±0.71%). An analysis of correlation between material properties revealed a positive relationship between ultimate tensile strength and elastic modulus (r(2)=0.79). Specifically, stiffer tendons were stronger, and we suggest that this correlation results from a constrained value of breaking strain, which did not vary significantly among tendons. This finding suggests an interdependence of material properties that may have a structural basis and may explain some adaptive responses observed in studies of tendon plasticity.

  10. Avaliação do resultado da reconstrução artroscópica do ligamento cruzado anterior do joelho com enxerto dos tendões flexores Evaluation of the results of arthroscopic ACL reconstruction with autogenous flexor tendons

    Directory of Open Access Journals (Sweden)

    Alexandre Almeida

    2010-01-01

    Full Text Available OBJETIVO: Avaliar o resultado da reconstrução do ligamento cruzado anterior (LCA com o autoenxerto dos tendões flexores da coxa. Serão analisados os dados com relação ao sexo, ao índice de massa corporal (IMC e a associação com fratura no membro inferior (MI. MÉTODOS: Foi analisado um grupo de 265 pacientes submetidos à artroscopia do joelho para fins de reconstrução do LCA com enxerto ipsilateral dos tendões flexores da coxa no período de 6 de julho de 2000 a 19 de novembro de 2007. RESULTADOS: 176 pacientes foram avaliados com média de 34,95 ± 18,8 meses (mediana 31 meses (IIQ: 20-48 meses. A avaliação mínima foi aos 12 meses e a máxima aos 87 meses. Obtivemos 138 (78,4% pacientes com resultado excelente, 22 (12,5% com resultado bom, oito (4,5% com resultado regular e oito (4,5% pacientes apresentaram resultado ruim. Não foi considerada significativa a maior incidência de bons e excelentes resultados para o sexo masculino (p = 0,128, para os pacientes com IMC OBJETIVE: To evaluate the results of single band arthroscopic anterior cruciate ligament (ACL reconstruction with flexor tendon autografts. We analyzed data about sex, body mass index (BMI and lower limb fracture associated with the initial trauma. METHODS: Two hundred and sixty-five patients who underwent arthroscopic anterior cruciate ligament (ACL reconstruction with ipsilateral thigh flexor tendon autografts from July 6, 2000, to November 19, 2007, were evaluated. RESULTS: One hundred and seventy-six patients were evaluated at an average follow up time of 34.95 ± 18.8 months (Median 31 months (IIQ: 20 - 48 months. The minimum evaluation time was 12 months and the maximum 87 months. One hundred and thirty-eight (78.4% patients had excellent results, 22 (12.5% patients good, 8 (4.5% patients fair, and 8 (4.5% poor results. No statistical significance was found for the better results for males (p = 0.128, for patients with a BMI < 25 (p = 0.848, or for patients

  11. Calcaneal tendon: imaging findings; Tendao calcaneo: avaliacao por imagem

    Energy Technology Data Exchange (ETDEWEB)

    Montandon, Cristiano; Fonseca, Cristiano Rezio; Montandon Junior, Marcelo Eustaquio [Colegio Brasileiro de Radiologia e Diagnostico por Imagem, Sao Paulo, SP (Brazil)]. E-mail: crismontandon@hotmail.com; Lobo, Leonardo Valadares; Ribeiro, Flavia Aparecida de Souza; Teixeira, Kim-Ir-Sen Santos [Goias Univ., Goiania, GO (Brazil). Hospital de Clinicas. Dept. de Diagnostico por Imagem e Anatomia Patologica

    2003-12-01

    We reviewed the radiological and clinical features of 23 patients with calcaneal tendon diseases, who were submitted to ultrasound or magnetic resonance imaging. The objective of this study was to characterize the lesions for a precise diagnosis of calcaneal tendon injuries. A wide range of calcaneal tendon diseases include degenerative lesions, inflammation of the peritendinous tissue such as peritendinitis and bursitis, and rupture. Imaging methods are essential in the diagnosis, treatment and follow-up of calcaneal tendon diseases. (author)

  12. Endoscopic Treatment of Intrasheath Peroneal Tendon Subluxation

    Directory of Open Access Journals (Sweden)

    Frederick Michels

    2013-01-01

    Full Text Available Intrasheath subluxation of the peroneal tendons within the peroneal groove is an uncommon problem. Open exploration combined with a peroneal groove-deepening procedure and retinacular reefing is the recommended treatment. This extensive lateral approach needs incision of the intact superior peroneal retinaculum and repair afterwards. We treated three patients with a painful intrasheath subluxation using an endoscopic approach. During this tendoscopy both tendons were inspected. The distal muscle fibers of the peroneus brevis tendon were resected in two patients. A partial tear was debrided in the third patient. All patients had a good result. No wound-healing problems or other complications occurred. Early return to work and sports was possible. An endoscopic approach was successful in treatment of an intrasheath subluxation of the peroneal tendons.

  13. Achilles tendon: US diagnosis of pathologic conditions. Work in progress

    International Nuclear Information System (INIS)

    Blei, C.L.; Nirschl, R.P.; Grant, E.G.

    1986-01-01

    Twenty-three patients were prospectively examined with ultra-sound (US) for acute or recurrent Achilles tendon symptoms. Three types of pathologic conditions of the Achilles tendon were found: tendinitis/tenosynovitis, acute tendon trauma, and postoperative changes. US appears to enable differentiation of these conditions and to contribute to the diagnosis of a broad range of Achilles tendon disorders

  14. Achilles tendon: US diagnosis of pathologic conditions. Work in progress

    Energy Technology Data Exchange (ETDEWEB)

    Blei, C.L.; Nirschl, R.P.; Grant, E.G.

    1986-06-01

    Twenty-three patients were prospectively examined with ultra-sound (US) for acute or recurrent Achilles tendon symptoms. Three types of pathologic conditions of the Achilles tendon were found: tendinitis/tenosynovitis, acute tendon trauma, and postoperative changes. US appears to enable differentiation of these conditions and to contribute to the diagnosis of a broad range of Achilles tendon disorders.

  15. Tendon synovial cells secrete fibronectin in vivo and in vitro

    International Nuclear Information System (INIS)

    Banes, A.J.; Link, G.W.; Bevin, A.G.; Peterson, H.D.; Gillespie, Y.; Bynum, D.; Watts, S.; Dahners, L.

    1988-01-01

    The chemistry and cell biology of the tendon have been largely overlooked due to the emphasis on collagen, the principle structural component of the tendon. The tendon must not only transmit the force of muscle contraction to bone to effect movement, but it must also glide simultaneously over extratendonous tissues. Fibronectin is classified as a cell attachment molecule that induces cell spreading and adhesion to substratum. The external surface of intact avian flexor tendon stained positively with antibody to cellular fibronectin. However, if the surface synovial cells were first removed with collagenase, no positive reaction with antifibronectin antibody was detected. Analysis of immunologically stained frozen sections of tendon also revealed fibronectin at the tendon synovium, but little was associated with cells internal in tendon. The staining pattern with isolated, cultured synovial cells and fibroblasts from the tendon interior substantiated the histological observations. Analysis of polyacrylamide gel profiles of 35 S-methionine-labeled proteins synthesized by synovial cells and internal fibroblasts indicated that fibronectin was synthesized principally by synovial cells. Fibronectin at the tendon surface may play a role in cell attachment to prevent cell removal by the friction of gliding. Alternatively, fibronectin, with its binding sites for hyaluronic acid and collagen, may act as a complex for boundary lubrication

  16. Sex Variation in Patellar Tendon Kinetics During Running

    Directory of Open Access Journals (Sweden)

    Sinclair Jonathan

    2015-06-01

    Full Text Available Purpose. The aim of the current investigation was to determine whether female recreational runners exhibit distinct patellar tendon loading patterns in relation to their male counterparts. Methods. Twelve male (age 26.55 ± 4.11 years, height 1.78 ± 0.11 m, mass 77.11 ± 5.06 kg and twelve female (age 26.67 ± 5.34 years, height 1.67 ± 0.12 m, mass 63.28 ± 9.75 kg runners ran over a force platform at 4.0 m · s-1. Lower limb kinematics were collected using an eight-camera optoelectric motion capture system which operated at 250 Hz. Patellar tendon loads were examined using a predictive algorithm. Sex differences in limb, knee and ankle joint stiffness were examined statistically using independent samples t tests. Results. The results indicate that patellar tendon force (male = 6.49 ± 2.28, female = 7.03 ± 1.35 and patelllar tendon loading rate (male = 92.41 ± 32.51, female = 111.05 ± 48.58 were significantly higher in female runners. Conclusions. Excessive tendon loading in female runners indicates that female runners may be at increased risk of patellar tendon pathologies.

  17. Effect of laceration and trimming of a tendon on the coefficient of friction along the A2 pulley: an in vitro study on turkey tendon.

    Science.gov (United States)

    Hajipour, L; Gulihar, A; Dias, J

    2010-08-01

    We carried out lacerations of 50%, followed by trimming, in ten turkey flexor tendons in vitro and measured the coefficient of friction at the tendon-pulley interface with loads of 200 g and 400 g and in 10 degrees , 30 degrees, 50 degrees and 70 degrees of flexion. Laceration increased the coefficient of friction from 0.12 for the intact tendon to 0.3 at both the test loads. Trimming the laceration reduced the coefficient of friction to 0.2. An exponential increase in the gliding resistance was found at 50 degrees and 70 degrees of flexion (p = 0.02 and p = 0.003, respectively) following trimming compared to that of the intact tendon. We concluded that trimming partially lacerated flexor tendons will reduce the gliding resistance at the tendon-pulley interface, but will lead to fragmentation and triggering of the tendon at higher degrees of flexion and loading. We recommend that higher degrees of flexion be avoided during early post-operative rehabilitation following trimming of a flexor tendon.

  18. Adaptive Remodeling of Achilles Tendon: A Multi-scale Computational Model.

    Directory of Open Access Journals (Sweden)

    Stuart R Young

    2016-09-01

    Full Text Available While it is known that musculotendon units adapt to their load environments, there is only a limited understanding of tendon adaptation in vivo. Here we develop a computational model of tendon remodeling based on the premise that mechanical damage and tenocyte-mediated tendon damage and repair processes modify the distribution of its collagen fiber lengths. We explain how these processes enable the tendon to geometrically adapt to its load conditions. Based on known biological processes, mechanical and strain-dependent proteolytic fiber damage are incorporated into our tendon model. Using a stochastic model of fiber repair, it is assumed that mechanically damaged fibers are repaired longer, whereas proteolytically damaged fibers are repaired shorter, relative to their pre-damage length. To study adaptation of tendon properties to applied load, our model musculotendon unit is a simplified three-component Hill-type model of the human Achilles-soleus unit. Our model results demonstrate that the geometric equilibrium state of the Achilles tendon can coincide with minimization of the total metabolic cost of muscle activation. The proposed tendon model independently predicts rates of collagen fiber turnover that are in general agreement with in vivo experimental measurements. While the computational model here only represents a first step in a new approach to understanding the complex process of tendon remodeling in vivo, given these findings, it appears likely that the proposed framework may itself provide a useful theoretical foundation for developing valuable qualitative and quantitative insights into tendon physiology and pathology.

  19. [Current problems in the reconstructive surgery of the locomotor apparatus in children].

    Science.gov (United States)

    Kupatadze, D D; Nabokov, V V; Malikov, S A; Polozov, R N; Kanina, L Ia; Veselov, A G

    1997-01-01

    The authors analyze results of treatment of 778 children with malignant and benign tumors of the bones, pseudoarthroses, amputations of lower extremities and fingers, injuries of the tendons, vessels and contused-lacerated wounds of distal phalanges of fingers. The possibility to use a precision technique for the reconstructive operations of the vessels in children is shown.

  20. The Relation between Calcium Supplement Consumption and Calcific Shoulder Tendonitis

    Directory of Open Access Journals (Sweden)

    Alireza Rouhani

    2015-10-01

    Full Text Available Background: Calcific tendonitis is a common cause of non-traumatic shoulder pain. Previous studies have suggested a relation between minerals and endocrine and calcium deposition. Thus, hypercalcemia is probably related to calcific tendonitis. This study aims at evaluating the relation found between calcium supplement consumption and calcific shoulder tendonitis. Methods: This analytical-descriptive study was conducted on 250 patients with shoulder pain referring to clinics and emergency department of Shohada Orthopedics Hospital during one year for considering calcific shoulder tendonitis and calcium supplement consumption. Patients with calcific tendonitis were treated and their functional ability was evaluated using DASH questionnaire, pain severity and range of motion (ROM before and after treatment and their correlation with calcium supplement consumption. Results: Calcific tendonitis and calcium consumption were generally seen in 30 (12% and 73 (29.2% cases, respectively. Calcium consumption frequency in patients with calcific tendonitis was significantly higher than the patients who did not consume calcium supplements (76.7% vs. 22.7%. Patients with calcific tendonitis who did not consume calcium supplements suffered from significantly longer periods of shoulder pain. All patients having consumed calcium supplement were female. The group who consumed calcium supplement had significantly severe pain and higher DASH score before and after treatment, while there was no significant difference in number of impaired ROM before and after treatment. Also, there was a negative correlation between calcium supplement consumption, pain severity and DASH score before and after treatment. Conclusion: Calcium supplement consumption is related to calcific tendonitis and is also accompanied with more pain and lower functional ability in patients with calcific tendonitis.    Keywords: Calcific tendonitis; Shoulder; Calcium supplement; Pain

  1. Complications and Adverse Events of a Randomized Clinical Trial Comparing 3 Graft Types for ACL Reconstruction.

    Science.gov (United States)

    Mohtadi, Nicholas; Barber, Rhamona; Chan, Denise; Paolucci, Elizabeth Oddone

    2016-05-01

    Complications/adverse events of anterior cruciate ligament (ACL) surgery are underreported, despite pooled level 1 data in systematic reviews. All adverse events/complications occurring within a 2-year postoperative period after primary ACL reconstruction, as part of a large randomized clinical trial (RCT), were identified and described. Prospective, double-blind randomized clinical trial. Patients and the independent trained examiner were blinded to treatment allocation. University-based orthopedic referral practice. Three hundred thirty patients (14-50 years; 183 males) with isolated ACL deficiency were intraoperatively randomized to ACL reconstruction with 1 autograft type. Graft harvest and arthroscopic portal incisions were identical. Patients were equally distributed to patellar tendon (PT), quadruple-stranded hamstring tendon (HT), and double-bundle (DB) hamstring autograft ACL reconstruction. Adverse events/complications were patient reported, documented, and diagnoses confirmed. Two major complications occurred: pulmonary embolism and septic arthritis. Twenty-four patients (7.3%) required repeat surgery, including 25 separate operations: PT = 7 (6.4%), HT = 9 (8.2%), and DB = 8 (7.3%). Repeat surgery was performed for meniscal tears (3.6%; n = 12), intra-articular scarring (2.7%; n = 9), chondral pathology (0.6%; n = 2), and wound dehiscence (0.3%; n = 1). Other complications included wound problems, sensory nerve damage, muscle tendon injury, tibial periostitis, and suspected meniscal tears and chondral lesions. Overall, more complications occurred in the HT/DB groups (PT = 24; HT = 31; DB = 45), but more PT patients complained of moderate or severe kneeling pain (PT = 17; HT = 9; DB = 4) at 2 years. Overall, ACL reconstructive surgery is safe. Major complications were uncommon. Secondary surgery was necessary 7.3% of the time for complications/adverse events (excluding graft reinjury or revisions) within the first 2 years. Level 1 (therapeutic studies

  2. Micromechanical properties and collagen composition of ruptured human achilles tendon

    DEFF Research Database (Denmark)

    Hansen, Philip; Kovanen, Vuokko; Hölmich, Per

    2013-01-01

    The Achilles tendon is one of the strongest tendons in the human body, and yet it frequently ruptures, which is a substantial clinical problem. However, the cause of ruptures remains elusive.......The Achilles tendon is one of the strongest tendons in the human body, and yet it frequently ruptures, which is a substantial clinical problem. However, the cause of ruptures remains elusive....

  3. Successful fifth metatarsal bulk autograft reconstruction of thermal necrosis post intramedullary fixation.

    Science.gov (United States)

    Veljkovic, Andrea; Le, Vu; Escudero, Mario; Salat, Peter; Wing, Kevin; Penner, Murray; Younger, Alastair

    2018-03-21

    Reamed intramedullary (IM) screw fixation for proximal fifth metatarsal fractures is technically challenging with potentially devastating complications if basic principles are not followed. A case of an iatrogenic fourth-degree burn after elective reamed IM screw fixation of a proximal fifth metatarsal fracture in a high-level athlete is reported. The case was complicated by postoperative osteomyelitis with third-degree soft-tissue defect. This was successfully treated with staged autologous bone graft reconstruction, tendon reconstruction, and local bi-pedicle flap coverage. The patient returned to competitive-level sports, avoiding the need for fifth ray amputation. Critical points of the IM screw technique and definitive reconstruction are discussed. Bulk autograft reconstruction is a safe and effective alternative to ray amputation in segmental defects of the fifth metatarsal.Level of evidence V.

  4. Ultrasound diagnostics of muscle and tendon injuries

    Directory of Open Access Journals (Sweden)

    Stević Ruža

    2009-01-01

    Full Text Available Introduction. Sonography is a useful technique for the investigation of a number of musculoskeletal disorders. The most common indication for ultrasonography of muscles and tendons is the diagnosis of traumatic lesions, distinguishing them from other disorders and follow-up of healing process. Objective. The purpose of this paper is to show the importance of ultrasound in the diagnosis of muscle and tendon injuries. Methods. The study included 170 patients (148 male and 22 female, mean age 29.6 years (range 14-60 years. All examinations were performed by linear transducer of 7.5-10 MHz, with longitudinal and transverse scanning. Ultrasound examination followed physical examination. Results. Traumatic lesions of muscles were diagnosed in 113 patients (66.7% and tendon injuries in 57 cases (33.2%. The muscle changes detected by ultrasonography were the following: 70 (61.9% partial and two (1.76% complete ruptures, 22 (19.46% haematoma, 9 (7.96% strains grade I, 4 fibroses and 4 ossifying myositis 4 (3.5%, respectively. Complications of muscle injuries were diagnosed in two cases, a muscular hernia and an arteriovenous fistula. Among tendon injuries, 21 (33.8% ruptures and 36 (66.1% tendinitis were diagnosed. Accompanying effusion in the bursa of patients with tendon injuries was found in 9 cases. Conclusion. Ultrasonography allowed visualization and objective assessment of the type and the extent of traumatic pathomorphological changes of muscles and tendons. Such diagnostic possibilities of ultrasonography are especially important in the choice of appropriate therapy.

  5. Quantitative Assessment of Tendon Healing by Using MR T2 Mapping in a Rabbit Achilles Tendon Transection Model Treated with Platelet-rich Plasma.

    Science.gov (United States)

    Fukawa, Taisuke; Yamaguchi, Satoshi; Watanabe, Atsuya; Sasho, Takahisa; Akagi, Ryuichiro; Muramatsu, Yuta; Akatsu, Yorikazu; Katsuragi, Joe; Endo, Jun; Osone, Fumio; Sato, Yasunori; Okubo, Toshiyuki; Takahashi, Kazuhisa

    2015-09-01

    To determine if magnetic resonance (MR) imaging T2 mapping can be used to quantify histologic tendon healing by using a rabbit Achilles tendon transection model treated with platelet-rich plasma (PRP). Experiments were approved by the Institutional Animal Care and Use Committee. The Achilles tendons of 24 New Zealand white rabbits (48 limbs) were surgically transected, and PRP (in the test group) or saline (in the control group) was injected into the transection site. The rabbits were sacrificed 2, 4, 8, and 12 weeks after surgery. Thereafter, T2 mapping and histologic evaluations were performed by using the Bonar scale. A mixed-model multivariate analysis of variance was used to test the effects of time and PRP treatment on the T2 value and Bonar grade, respectively. The correlation between the T2 value and Bonar grade was also assessed by using the Spearman correlation coefficient. The Bonar scale values decreased in both groups during tendon healing. The T2 value also shortened over time (P tendon healing. While T2 and Bonar grade were lower at all time points in tendons treated with PRP, there was no significant difference between the treatment and control tendons.

  6. Central Tendon Injuries of Hamstring Muscles: Case Series of Operative Treatment.

    Science.gov (United States)

    Lempainen, Lasse; Kosola, Jussi; Pruna, Ricard; Puigdellivol, Jordi; Sarimo, Janne; Niemi, Pekka; Orava, Sakari

    2018-02-01

    As compared with injuries involving muscle only, those involving the central hamstring tendon have a worse prognosis. Limited information is available regarding the surgical treatment of central tendon injuries of the hamstrings. To describe the operative treatment and outcomes of central tendon injuries of the hamstrings among athletes. Case series; Level of evidence, 4. Eight athletes (6 top level, 2 recreational) with central hamstring tendon injuries underwent magnetic resonance imaging and surgical treatment. The indication for surgery was recurrent (n = 6) or acute (n = 2) central hamstring tendon injury. All patients followed the same postoperative rehabilitation protocol, and return to play was monitored. Magnetic resonance imaging found a central tendon injury in all 3 hamstring muscles (long head of the biceps femoris, semimembranosus, and semitendinosus) with disrupted tendon ends. In acute and recurrent central tendon injuries, full return to play was achieved at 2.5 to 4 months. There were no adverse events during follow-up. Central tendon injuries of the hamstrings can be successfully repaired surgically after acute and recurrent ruptures.

  7. Smad3 binds Scleraxis and Mohawk and regulates tendon matrix organization.

    Science.gov (United States)

    Berthet, Ellora; Chen, Carol; Butcher, Kristin; Schneider, Richard A; Alliston, Tamara; Amirtharajah, Mohana

    2013-09-01

    TGFβ plays a critical role in tendon formation and healing. While its downstream effector Smad3 has been implicated in the healing process, little is known about the role of Smad3 in normal tendon development or tenocyte gene expression. Using mice deficient in Smad3 (Smad3(-/-) ), we show that Smad3 ablation disrupts tendon architecture and has a dramatic impact on normal gene and protein expression during development as well as in mature tendon. In developing and adult tendon, loss of Smad3 results in reduced protein expression of the matrix components Collagen 1 and Tenascin-C. Additionally, when compared to wild type, tendon from adult Smad3(-/-) mice shows a down regulation of key tendon marker genes. Finally, we have established that Smad3 has the ability to physically interact with the critical transcriptional regulators Scleraxis and Mohawk. Together these results indicate a central role for Smad3 in normal tendon formation and in the maintenance of mature tendon. Copyright © 2013 Orthopaedic Research Society.

  8. Central Tendon Injuries of Hamstring Muscles: Case Series of Operative Treatment

    Science.gov (United States)

    Lempainen, Lasse; Kosola, Jussi; Pruna, Ricard; Puigdellivol, Jordi; Sarimo, Janne; Niemi, Pekka; Orava, Sakari

    2018-01-01

    Background: As compared with injuries involving muscle only, those involving the central hamstring tendon have a worse prognosis. Limited information is available regarding the surgical treatment of central tendon injuries of the hamstrings. Purpose: To describe the operative treatment and outcomes of central tendon injuries of the hamstrings among athletes. Study Design: Case series; Level of evidence, 4. Methods: Eight athletes (6 top level, 2 recreational) with central hamstring tendon injuries underwent magnetic resonance imaging and surgical treatment. The indication for surgery was recurrent (n = 6) or acute (n = 2) central hamstring tendon injury. All patients followed the same postoperative rehabilitation protocol, and return to play was monitored. Results: Magnetic resonance imaging found a central tendon injury in all 3 hamstring muscles (long head of the biceps femoris, semimembranosus, and semitendinosus) with disrupted tendon ends. In acute and recurrent central tendon injuries, full return to play was achieved at 2.5 to 4 months. There were no adverse events during follow-up. Conclusion: Central tendon injuries of the hamstrings can be successfully repaired surgically after acute and recurrent ruptures. PMID:29479545

  9. Ultrasound-based testing of tendon mechanical properties

    DEFF Research Database (Denmark)

    Seynnes, O R; Bojsen-Møller, J.; Albracht, K

    2015-01-01

    In the past 20 years, the use of ultrasound-based methods has become a standard approach to measure tendon mechanical properties in vivo. Yet the multitude of methodological approaches adopted by various research groups probably contribute to the large variability of reported values. The technique......, or signal synchronization; and 2) in physiological considerations related to the viscoelastic behavior or length measurements of tendons. Hence, the purpose of the present review is to assess and discuss the physiological and technical aspects connected to in vivo testing of tendon mechanical properties...

  10. Magnetic resonance imaging and computed radiography in Achilles tendon rupture

    International Nuclear Information System (INIS)

    Korenaga, Tateo; Hachiya, Junichi; Miyasaka, Yasuo

    1988-01-01

    Magnetic Resonance Imaging (MRI) and Computed Radiography (CR) were performed in 15 patients with complete Achilles tendon rupture who were treated conservatively without surgery. MRI was obtained using Toshiba MRT 50 A superconductive machine, operaing at 0.5 Tesla. CR was performed by CR-101, Fuji Medical System. In fresh cases, ruptured tendons showed intermediate signal intensity on T1-weighted images and high intensity on T2-weighted images. Thickening of the tendon was observed in all cases except in very acute stage. Configuration of thickend tendons tends to be dumbbell shape in subacute stage and fusiform in chronic stage of more than six months after the initial trauma. In cases which showed high signal intensity at the ruptured area both on T1 and T2 weighted images, migration of fat into the sapces between the ruptured tendons was considered to be the major source of increased signal intensity. Computed radiography showed thickening of the tendon, blurring of anterior margin of the tendon, and decreased translucency of pre-Achilles fat pad. However, MRI better demonstrated the details of ruptured tendons when compared to CR, and thought to be an usefull way of following up the healing process of the ruptured tendon to facilitate more reasonable judgement of the time of removing plaster casts and stating exercise. (author)

  11. Effect of aging and exercise on the tendon

    DEFF Research Database (Denmark)

    Svensson, Rene B; Heinemeier, Katja Maria; Couppé, Christian

    2016-01-01

    Here, we review the literature on how tendons respond and adapt to ageing and exercise. With respect to aging, there are considerable changes early in life, but this seems to be maturation rather than aging per se. In vitro data indicate that aging is associated with a decreased potential for cel...... and modulus of the tendon and may reduce the amount of glycation. Exercise thereby tends to counteract the effects of aging.......Here, we review the literature on how tendons respond and adapt to ageing and exercise. With respect to aging, there are considerable changes early in life, but this seems to be maturation rather than aging per se. In vitro data indicate that aging is associated with a decreased potential for cell...... glycation-derived cross-links increase substantially. Mechanically, aging appears to be associated with a reduction in modulus and strength. With respect to exercise, tendon cells respond by producing growth factors, and there is some support for a loading-induced increase in tendon collagen synthesis...

  12. [Achilles tendon ruptures: 25 year's experience in sport-orthopedic treatment].

    Science.gov (United States)

    Majewski, M; Widmer, K H; Steinbrück, K

    2002-12-01

    From 1972 - 1996 570 Achilles tendon ruptures in 565 patients were treated in the Sportklinik Stuttgart. The 499 men and 66 women had an average age of 38 years. For the diagnosis of a Achilles tendon rupture Ultrasound and MRI are important procedures, but clinical history and examination are still the best methods to find an Achilles tendon rupture (100%). However,the Actiology of the Achilles tendon rupture is still controversial and cannot be answered by these methods. Opposed to the degenerative theory, biomechanical experiments show that any Achilles tendon can tear when the calf muscle is tensed before the tendon is quickly stretched. We found that 69.8% of the patients with Achilles tendon rupture had a real trauma. Regardless of that, the treatment of the ruptured Achilles tendon has considerably changed over the last ten years. Responsible for this development are the positive experiences at the field of sports medicine with minimally invasive methods and the early functional treatment after knee surgery. Since we use an early functional rehabilitation concept instead of plaster immobilisation, all methods to treat a ruptured Achilles tendon have been improved. 43.5% of the patients after plaster immobilisation and 28.8% of the patients after early functional rehabilitation had a subjectively felt force reduction. Other important selecting criteria are the risk factors related to treatment method. Minimal invasive percutaneous Achilles tendon repair is considerably better than conservative therapy with a high rate of re-rupture (9.8%) and better than the open surgical repair, which carries a higher risk of infection (2.2%)

  13. Contrast material filling of the peroneal tendon sheath

    International Nuclear Information System (INIS)

    Zadravecz, Gy.; Grexa, E.

    1981-01-01

    In case of complaints after fracture of the calcaneus the common sheath of the peroneus tendons was filled up with contrast material. The tendon sheath was punctured Oehind the external ankle. The three-directional radiograms clearly showed the dislocation and compression of the tendons, caused by the exostosis of the calcaneus. The concomitant tendovaginitis caused the complaints. This alteration was observed in 11% of all the calcaneus fractures. (L.E.)

  14. Reproducibility of Ultrasound and Magnetic Resonance Imaging Measurements of Tendon Size

    International Nuclear Information System (INIS)

    Brushoej, C.; Henriksen, B.M.; Albrecht-Beste, E.; Hoelmich, P.; Larsen, K.; Bachmann Nielsen, M.

    2006-01-01

    Purpose: To investigate the intra- and inter-tester reproducibility of measurements of the Achilles tendon, tibialis anterior tendon, and the tibialis posterior tendon in football players using ultrasound (US) and magnetic resonance imaging (MRI). Material and Methods: Eleven asymptomatic football players were examined. Using a standardized US scanning protocol, the tendons were examined by two observers with US for thickness, width, and cross-sectional area. One observer conducted the procedure twice. The subjects also underwent an MRI examination, and the assessment of tendon size was conducted twice by two observers. Results: The best reproducibility judged by coefficient of variation (CV) and 95% confidence interval was determined for the Achilles tendon on both US and MRI. The variability of US on measurements on the tibialis anterior and tibialis posterior tendons was less than that when using MRI. In 12 out of 18 measurements, there were systematic differences between observers as judged by one-sided F-test. Conclusion: The reproducibility of the three tendons was limited. Precaution should be taken when looking for minor quantitative changes, i.e., training-induced hypertrophy, and when doing so, the Achilles tendon should be used

  15. Identification of Novel Equine (Equus caballus Tendon Markers Using RNA Sequencing

    Directory of Open Access Journals (Sweden)

    Jan M. Kuemmerle

    2016-11-01

    Full Text Available Although several tendon-selective genes exist, they are also expressed in other musculoskeletal tissues. As cell and tissue engineering is reliant on specific molecular markers to discriminate between cell types, tendon-specific genes need to be identified. In order to accomplish this, we have used RNA sequencing (RNA-seq to compare gene expression between tendon, bone, cartilage and ligament from horses. We identified several tendon-selective gene markers, and established eyes absent homolog 2 (EYA2 and a G-protein regulated inducer of neurite outgrowth 3 (GPRIN3 as specific tendon markers using RT-qPCR. Equine tendon cells cultured as three-dimensional spheroids expressed significantly greater levels of EYA2 than GPRIN3, and stained positively for EYA2 using immunohistochemistry. EYA2 was also found in fibroblast-like cells within the tendon tissue matrix and in cells localized to the vascular endothelium. In summary, we have identified EYA2 and GPRIN3 as specific molecular markers of equine tendon as compared to bone, cartilage and ligament, and provide evidence for the use of EYA2 as an additional marker for tendon cells in vitro.

  16. Influence of repetitive mechanical loading on MMP2 activity in tendon fibroblasts.

    Science.gov (United States)

    Huisman, Elise; Lu, Alex; Jamil, Sarwat; Mousavizadeh, Rouhollah; McCormack, Robert; Roberts, Clive; Scott, Alex

    2016-11-01

    Matrix metalloproteinase2 has been implicated in tendon pathology caused by repetitive movements. However, its activity in the early stages of the tendon's response to overuse, and its presence in the circulation as a possible indicator of tendon degradation, remain unknown. Human tendon cells were repetitively stretched for 5 days, and the rabbit Achilles tendon complex underwent repetitive motion 3× per week for 2 weeks. Quantitative polymer chain reaction analysis was performed to detect matrix metalloproteinase2/14 and tissue inhibitor of matrix metalloproteinase2 messenger ribonucleic acid of cells and rabbit tissue, and matrix metalloproteinase2 protein levels were determined with an enzyme linked immunoassay. Matrix metalloproteinase2 activity was examined using zymography of the conditioned media, tendon and serum. Immunohistochemistry was used to localize matrix metalloproteinase2 in tendon tissue, and the density of fibrillar collagen in tendons was examined using second harmonic generation microscopy. Tendon cells stretched with high strain or high frequency demonstrated increased matrix metalloproteinase2 messenger ribonucleic acid and protein levels. Matrix metalloproteinase2 activity was increased in the rabbit Achilles tendon tissue at weeks 1 and 2; however, serum activity was only increased at week 1. After 2 weeks of exercise, the collagen density was lower in specific regions of the exercised rabbit Achilles tendon complex. Matrix metalloproteinase2 expression in exercised rabbit Achilles tendons was detected surrounding tendon fibroblasts. Repetitive mechanical stimulation of tendon cells results in a small increase in matrix metalloproteinase2 levels, but it appears unlikely that serum matrix metalloproteinase2 will be a useful indicator of tendon overuse injury. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1991-2000, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. Different Achilles Tendon Pathologies Show Distinct Histological and Molecular Characteristics

    Directory of Open Access Journals (Sweden)

    Franka Klatte-Schulz

    2018-01-01

    Full Text Available Reasons for the development of chronic tendon pathologies are still under debate and more basic knowledge is needed about the different diseases. The aim of the present study was therefore to characterize different acute and chronic Achilles tendon disorders. Achilles tendon samples from patients with chronic tendinopathy (n = 7, chronic ruptures (n = 6, acute ruptures (n = 13, and intact tendons (n = 4 were analyzed. The histological score investigating pathological changes was significantly increased in tendinopathy and chronic ruptures compared to acute ruptures. Inflammatory infiltration was detected by immunohistochemistry in all tendon pathology groups, but was significantly lower in tendinopathy compared to chronic ruptures. Quantitative real-time PCR (qRT-PCR analysis revealed significantly altered expression of genes related to collagens and matrix modeling/remodeling (matrix metalloproteinases, tissue inhibitors of metalloproteinases in tendinopathy and chronic ruptures compared to intact tendons and/or acute ruptures. In all three tendon pathology groups markers of inflammation (interleukin (IL 1β, tumor necrosis factor α, IL6, IL10, IL33, soluble ST2, transforming growth factor β1, cyclooxygenase 2, inflammatory cells (cluster of differentaition (CD 3, CD68, CD80, CD206, fat metabolism (fatty acid binding protein 4, peroxisome proliferator-activated receptor γ, CCAAT/enhancer-binding protein α, adiponectin, and innervation (protein gene product 9.5, growth associated protein 43, macrophage migration inhibitory factor were detectable, but only in acute ruptures significantly regulated compared to intact tendons. The study gives an insight into structural and molecular changes of pathological processes in tendons and might be used to identify targets for future therapy of tendon pathologies.

  18. Partial lesions of the intratemporal segment of the facial nerve: graft versus partial reconstruction.

    Science.gov (United States)

    Bento, Ricardo F; Salomone, Raquel; Brito, Rubens; Tsuji, Robinson K; Hausen, Mariana

    2008-09-01

    In cases of partial lesions of the intratemporal segment of the facial nerve, should the surgeon perform an intraoperative partial reconstruction, or partially remove the injured segment and place a graft? We present results from partial lesion reconstruction on the intratemporal segment of the facial nerve. A retrospective study on 42 patients who presented partial lesions on the intratemporal segment of the facial nerve was performed between 1988 and 2005. The patients were divided into 3 groups based on the procedure used: interposition of the partial graft on the injured area of the nerve (group 1; 12 patients); keeping the preserved part and performing tubulization (group 2; 8 patients); and dividing the parts of the injured nerve (proximal and distal) and placing a total graft of the sural nerve (group 3; 22 patients). Fracture of the temporal bone was the most frequent cause of the lesion in all groups, followed by iatrogenic causes (p lesion of the facial nerve is still questionable. Among these 42 patients, the best results were those from the total graft of the facial nerve.

  19. The effect of acute exercise on collagen turnover in human tendons

    DEFF Research Database (Denmark)

    Mørch, Lina Steinrud; Pingel, Jessica; Boesen, Mikael

    2013-01-01

    Mechanical loading of human tendon stimulates collagen synthesis, but the relationship between acute loading responses and training status of the tendon is not clear. We tested the effect of prolonged load deprivation on the acute loading-induced collagen turnover in human tendons, by applying...... the contra-lateral leg was used habitually. Following the procedure both Achilles tendons and calf muscles were loaded with the same absolute load during a 1-h treadmill run. Tissue collagen turnover was measured by microdialysis performed post-immobilization but pre-exercise around both Achilles tendons...... and compared to values obtained by 72-h post-exercise. Power Doppler was used to monitor alterations in intratendinous blood flow velocity of the Achilles tendon and MRI used to quantitate changes in tendon cross-section area. Acute loading resulted in an increased collagen synthesis 72 h after the run in both...

  20. Arthroscopically-Asissted Achilles Tendon Repair; Long-Term Results

    OpenAIRE

    Turgut, Ak?n; Asfuro?lu, Mert Zeynel

    2014-01-01

    Objectives: The ruptures of the Achilles tendon (AT) are relatively common. Since there is no consensus on the best method of the repair of the AT; the treatment is determined on the preference of the surgeon and the patient. The study evaluating the cadaveric and short term clinical results done by our clinic in 2002, has shown us that arthroscopically Achilles tendon repair can be good choise in achilles tendon ruptures. Methods: Fortyfour patients who underwent arthroscopically assisted ac...

  1. Ossification of the bilateral Achilles tendon: a rare entity

    International Nuclear Information System (INIS)

    Arora, Abhishek J; Arora, Richa

    2015-01-01

    Ossification of the Achilles tendon is a rare clinical entity comprising of one or more segments of variable sized ossified masses in the fibrocartilaginous substance of the tendon. The etiology of ossification of the Achilles tendon is multifactorial with recurrent trauma and surgery comprising major predisposing factors, with others being metabolic, systemic, and infectious diseases. The possibility of a genetic predisposition towards this entity has also been raised, but has not yet been proven. We present a rare case of ossification of the bilateral Achilles tendons without any history of trauma or surgery in a 48-year-old female patient

  2. HGF mediates the anti-inflammatory effects of PRP on injured tendons.

    Directory of Open Access Journals (Sweden)

    Jianying Zhang

    Full Text Available Platelet-rich plasma (PRP containing hepatocyte growth factor (HGF and other growth factors are widely used in orthopaedic/sports medicine to repair injured tendons. While PRP treatment is reported to decrease pain in patients with tendon injury, the mechanism of this effect is not clear. Tendon pain is often associated with tendon inflammation, and HGF is known to protect tissues from inflammatory damages. Therefore, we hypothesized that HGF in PRP causes the anti-inflammatory effects. To test this hypothesis, we performed in vitro experiments on rabbit tendon cells and in vivo experiments on a mouse Achilles tendon injury model. We found that addition of PRP or HGF decreased gene expression of COX-1, COX-2, and mPGES-1, induced by the treatment of tendon cells in vitro with IL-1β. Further, the treatment of tendon cell cultures with HGF antibodies reduced the suppressive effects of PRP or HGF on IL-1β-induced COX-1, COX-2, and mPGES-1 gene expressions. Treatment with PRP or HGF almost completely blocked the cellular production of PGE2 and the expression of COX proteins. Finally, injection of PRP or HGF into wounded mouse Achilles tendons in vivo decreased PGE2 production in the tendinous tissues. Injection of platelet-poor plasma (PPP however, did not reduce PGE2 levels in the wounded tendons, but the injection of HGF antibody inhibited the effects of PRP and HGF. Further, injection of PRP or HGF also decreased COX-1 and COX-2 proteins. These results indicate that PRP exerts anti-inflammatory effects on injured tendons through HGF. This study provides basic scientific evidence to support the use of PRP to treat injured tendons because PRP can reduce inflammation and thereby reduce the associated pain caused by high levels of PGE2.

  3. HGF Mediates the Anti-inflammatory Effects of PRP on Injured Tendons

    Science.gov (United States)

    Zhang, Jianying; Middleton, Kellie K.; Fu, Freddie H.; Im, Hee-Jeong; Wang, James H-C.

    2013-01-01

    Platelet-rich plasma (PRP) containing hepatocyte growth factor (HGF) and other growth factors are widely used in orthopaedic/sports medicine to repair injured tendons. While PRP treatment is reported to decrease pain in patients with tendon injury, the mechanism of this effect is not clear. Tendon pain is often associated with tendon inflammation, and HGF is known to protect tissues from inflammatory damages. Therefore, we hypothesized that HGF in PRP causes the anti-inflammatory effects. To test this hypothesis, we performed in vitro experiments on rabbit tendon cells and in vivo experiments on a mouse Achilles tendon injury model. We found that addition of PRP or HGF decreased gene expression of COX-1, COX-2, and mPGES-1, induced by the treatment of tendon cells in vitro with IL-1β. Further, the treatment of tendon cell cultures with HGF antibodies reduced the suppressive effects of PRP or HGF on IL-1β-induced COX-1, COX-2, and mPGES-1 gene expressions. Treatment with PRP or HGF almost completely blocked the cellular production of PGE2 and the expression of COX proteins. Finally, injection of PRP or HGF into wounded mouse Achilles tendons in vivo decreased PGE2 production in the tendinous tissues. Injection of platelet-poor plasma (PPP) however, did not reduce PGE2 levels in the wounded tendons, but the injection of HGF antibody inhibited the effects of PRP and HGF. Further, injection of PRP or HGF also decreased COX-1 and COX-2 proteins. These results indicate that PRP exerts anti-inflammatory effects on injured tendons through HGF. This study provides basic scientific evidence to support the use of PRP to treat injured tendons because PRP can reduce inflammation and thereby reduce the associated pain caused by high levels of PGE2. PMID:23840657

  4. Bilateral synchronous rupture of the quadriceps tendon.

    LENUS (Irish Health Repository)

    Ellanti, P

    2012-09-01

    Bilateral simultaneous rupture of the quadriceps tendon is a rare entity. They are often associated with degenerative changes of the tendons and predisposing conditions such as diabetes or excessive steroid use. They most commonly tend to occur in patients of 40 years of age or older.

  5. Nonlinear model for viscoelastic behavior of Achilles tendon.

    Science.gov (United States)

    Kahn, Cyril J F; Wang, Xiong; Rahouadj, Rachid

    2010-11-01

    Although the mechanical properties of ligament and tendon are well documented in research literature, very few unified mechanical formulations can describe a wide range of different loadings. The aim of this study was to propose a new model, which can describe tendon responses to various solicitations such as cycles of loading, unloading, and reloading or successive relaxations at different strain levels. In this work, experiments with cycles of loading and reloading at increasing strain level and sequences of relaxation were performed on white New Zealand rabbit Achilles tendons. We presented a local formulation of thermodynamic evolution outside equilibrium at a representative element volume scale to describe the tendon's macroscopic behavior based on the notion of relaxed stress. It was shown that the model corresponds quite well to the experimental data. This work concludes with the complexity of tendons' mechanical properties due to various microphysical mechanisms of deformation involved in loading such as the recruitment of collagen fibers, the rearrangement of the microstructure (i.e., collagens type I and III, proteoglycans, and water), and the evolution of relaxed stress linked to these mechanisms.

  6. The role of ultrasound in the management of flexor tendon injuries.

    Science.gov (United States)

    Jeyapalan, K; Bisson, M A; Dias, J J; Griffin, Y; Bhatt, R

    2008-08-01

    The use of ultrasound scanning to establish tendon pathologies was assessed retrospectively in 17 patients in 18 digits. The ultrasound scan demonstrated four patterns: (1) normal intact tendons in four, (2) ruptured tendons in three, (3) tendons in continuity but attenuated in five and (4) tendons in continuity but thickened with fibrosis and decreased movement representing adhesions in five patients. Surgery was undertaken in only three cases, confirming the ultrasound diagnosis in two. Surgery was offered to all three patients with ruptures but was declined by two. Ultrasound imaging helped to avoid surgery in 14 cases by excluding flexor tendon re-ruptures. This allowed on-going mobilisation, leading to recovery of function.

  7. Effects of celecoxib on proliferation and tenocytic differentiation of tendon-derived stem cells

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Kairui; Zhang, Sheng [Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China); Li, Qianqian [Cancer Research Institute, Southern Medical University, Guangzhou 510515 (China); Yang, Jun [Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China); Department of Orthopaedics, 421 Hospital of PLA, Guangzhou 510318 (China); Dong, Weiqiang [Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China); Department of Orthopaedics, The First Affiliated Hospital to Guangzhou Medical University, Guangzhou 510120 (China); Wang, Shengnan; Cheng, Yirong; Al-Qwbani, Mohammed [Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China); Wang, Qiang, E-mail: 1780468505@qq.com [Department of Orthopaedics, Subei People’s Hospital of Jiangsu Province (Clinical Medical College of Yangzhou University), Yangzhou, Jiangsu Province 225001 (China); Yu, Bin, E-mail: carryzhang1985@live.com [Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China)

    2014-07-18

    Highlights: • Celecoxib has no effects on TDSCs cell proliferation in various concentrations. • Celecoxib reduced mRNAs levels of tendon associated transcription factor. • Celecoxib reduced mRNAs levels of main tendon associated collagen. • Celecoxib reduced mRNAs levels of tendon associated molecules. - Abstract: NSAIDs are often ingested to reduce the pain and improve regeneration of tendon after tendon injury. Although the effects of NSAIDs in tendon healing have been reported, the data and conclusions are not consistent. Recently, tendon-derived stem cells (TDSCs) have been isolated from tendon tissues and has been suggested involved in tendon repair. Our study aims to determine the effects of COX-2 inhibitor (celecoxib) on the proliferation and tenocytic differentiation of TDSCs. TDSCs were isolated from mice Achilles tendon and exposed to celecoxib. Cell proliferation rate was investigated at various concentrations (0.1, 1, 10 and 100 μg/ml) of celecoxib by using hemocytometer. The mRNA expression of tendon associated transcription factors, tendon associated collagens and tendon associated molecules were determined by reverse transcription-polymerase chain reaction. The protein expression of Collagen I, Collagen III, Scleraxis and Tenomodulin were determined by Western blotting. The results showed that celecoxib has no effects on TDSCs cell proliferation in various concentrations (p > 0.05). The levels of most tendon associated transcription factors, tendon associated collagens and tendon associated molecules genes expression were significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). Collagen I, Collagen III, Scleraxis and Tenomodulin protein expression were also significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). In conclusion, celecoxib inhibits tenocytic differentiation of tendon-derived stem cells but has no effects on cell proliferation.

  8. Effects of celecoxib on proliferation and tenocytic differentiation of tendon-derived stem cells

    International Nuclear Information System (INIS)

    Zhang, Kairui; Zhang, Sheng; Li, Qianqian; Yang, Jun; Dong, Weiqiang; Wang, Shengnan; Cheng, Yirong; Al-Qwbani, Mohammed; Wang, Qiang; Yu, Bin

    2014-01-01

    Highlights: • Celecoxib has no effects on TDSCs cell proliferation in various concentrations. • Celecoxib reduced mRNAs levels of tendon associated transcription factor. • Celecoxib reduced mRNAs levels of main tendon associated collagen. • Celecoxib reduced mRNAs levels of tendon associated molecules. - Abstract: NSAIDs are often ingested to reduce the pain and improve regeneration of tendon after tendon injury. Although the effects of NSAIDs in tendon healing have been reported, the data and conclusions are not consistent. Recently, tendon-derived stem cells (TDSCs) have been isolated from tendon tissues and has been suggested involved in tendon repair. Our study aims to determine the effects of COX-2 inhibitor (celecoxib) on the proliferation and tenocytic differentiation of TDSCs. TDSCs were isolated from mice Achilles tendon and exposed to celecoxib. Cell proliferation rate was investigated at various concentrations (0.1, 1, 10 and 100 μg/ml) of celecoxib by using hemocytometer. The mRNA expression of tendon associated transcription factors, tendon associated collagens and tendon associated molecules were determined by reverse transcription-polymerase chain reaction. The protein expression of Collagen I, Collagen III, Scleraxis and Tenomodulin were determined by Western blotting. The results showed that celecoxib has no effects on TDSCs cell proliferation in various concentrations (p > 0.05). The levels of most tendon associated transcription factors, tendon associated collagens and tendon associated molecules genes expression were significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). Collagen I, Collagen III, Scleraxis and Tenomodulin protein expression were also significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). In conclusion, celecoxib inhibits tenocytic differentiation of tendon-derived stem cells but has no effects on cell proliferation

  9. Bevacizumab Improves Achilles Tendon Repair in a Rat Model

    Directory of Open Access Journals (Sweden)

    Herbert Tempfer

    2018-04-01

    Full Text Available Background/Aims: Effective wound-healing generally requires efficient re-vascularization after injury, ensuring sufficient supply with oxygen, nutrients, and various cell populations. While this applies to most tissues, tendons are mostly avascular in nature and harbor relatively few cells, probably contributing to their poor regenerative capacity. Considering the minimal vascularization of healthy tendons, we hypothesize that controlling angiogenesis in early tendon healing is beneficial for repair tissue quality and function. Methods: To address this hypothesis, Bevacizumab, a monoclonal antibody blocking VEGF-A signaling, was locally injected into the defect area of a complete tenotomy in rat Achilles tendon. At 28 days post-surgery, the defect region was investigated using immunohistochemistry against vascular and lymphatic epitopes. Polarization microscopy and biomechanical testing was used to determine tendon integrity and gait analysis for functional testing in treated vs non-treated animals. Results: Angiogenesis was found to be significantly reduced in the Bevacizumab treated repair tissue, accompanied by significantly reduced cross sectional area, improved matrix organization, increased stiffness and Young’s modulus, maximum load and stress. Further, we observed an improved gait pattern when compared to the vehicle injected control group. Conclusion: Based on the results of this study we propose that reducing angiogenesis after tendon injury can improve tendon repair, potentially representing a novel treatment-option.

  10. RECONSTRUCTION OF POST ELECTRIC BURN DEFECTS OF UPPER LIMB WITH DIFFERENT FLAPS

    Directory of Open Access Journals (Sweden)

    Satyajit

    2015-08-01

    Full Text Available INTRODUCTION: P ost electric burn defects are difficult to manage due to deep injury involving all the structures up to bony level. A good vascularized flap is required to resurface the defect for preventing the complication and for reconstruction of involved structures. AIM: Resurfacing the post electric burn defect with different flaps according to need of the defect. MATERIAL AND METHOD: All patients of electric burn hand and fore arm defect admitted to burn, p lastic and reconstructi ve department of SCB Medical College &hospital, Cuttack between January 2012 to December 2012 were included in the study. During this period the patients were followed up at weekly interval for first 2 month, then at 1 monthly interv al for next 6 - 8 month. OBSERVATION: Out of 40 cases of post electric burn forearm and hand reconstruction, 10 cases underwent groin flap cover, 6 cases underwent abdominal flap cover, 5 cases underwent cross finger flap cover 5 cases underwent free antero lateral thigh flap cover, 4 cases underwent free latissimus dorsi flap cover, 5 cases underwent first dorsal metacarpal artery flap cover, 5 cases reverse radial forearm flap cover. All the defects were resurfaced successfully with flaps. Four had marginal necrosis and six had wound infection. Eventually all flaps settled well without further intervention. Due to involvement of all important tendons & nerves, functional outcome is guarded. DISCUSSION: Hand and forearm are most commonly and most severely aff ected in electric burn injury because they are mostly first part of body to come in contact with electric circuit. Even though at initial part the injury appears to be superficial, deepe r structures like bone, tendon and neurovascular bundles are affected requiring flap cover for future reconstruction of these structures to get functional and sensate hand. CONCLUSION: Reconstruction of post electric burn defect of distal forearm and hand represents great challenge due to

  11. Achilles tendon shape and echogenicity on ultrasound among active badminton players.

    Science.gov (United States)

    Malliaras, P; Voss, C; Garau, G; Richards, P; Maffulli, N

    2012-04-01

    The relationship between Achilles tendon ultrasound abnormalities, including a spindle shape and heterogeneous echogenicity, is unclear. This study investigated the relationship between these abnormalities, tendon thickness, Doppler flow and pain. Sixty-one badminton players (122 tendons, 36 men, and 25 women) were recruited. Achilles tendon thickness, shape (spindle, parallel), echogenicity (heterogeneous, homogeneous) and Doppler flow (present or absent) were measured bilaterally with ultrasound. Achilles tendon pain (during or after activity over the last week) and pain and function [Victorian Institute of Sport Achilles Assessment (VISA-A)] were measured. Sixty-eight (56%) tendons were parallel with homogeneous echogenicity (normal), 22 (18%) were spindle shaped with homogeneous echogenicity, 16 (13%) were parallel with heterogeneous echogenicity and 16 (13%) were spindle shaped with heterogeneous echogenicity. Spindle shape was associated with self-reported pain (P<0.05). Heterogeneous echogenicity was associated with lower VISA-A scores than normal tendon (P<0.05). There was an ordinal relationship between normal tendon, parallel and heterogeneous and spindle shaped and heterogeneous tendons with regard to increasing thickness and likelihood of Doppler flow. Heterogeneous echogenicity with a parallel shape may be a physiological phase and may develop into heterogeneous echogenicity with a spindle shape that is more likely to be pathological. © 2010 John Wiley & Sons A/S.

  12. A passive exoskeleton with artificial tendons: design and experimental evaluation.

    Science.gov (United States)

    van Dijk, Wietse; van der Kooij, Herman; Hekman, Edsko

    2011-01-01

    We developed a passive exoskeleton that was designed to minimize joint work during walking. The exoskeleton makes use of passive structures, called artificial tendons, acting in parallel with the leg. Artificial tendons are elastic elements that are able to store and redistribute energy over the human leg joints. The elastic characteristics of the tendons have been optimized to minimize the mechanical work of the human leg joints. In simulation the maximal reduction was 40 percent. The performance of the exoskeleton was evaluated in an experiment in which nine subjects participated. Energy expenditure and muscle activation were measured during three conditions: Normal walking, walking with the exoskeleton without artificial tendons, and walking with the exoskeleton with the artificial tendons. Normal walking was the most energy efficient. While walking with the exoskeleton, the artificial tendons only resulted in a negligibly small decrease in energy expenditure. © 2011 IEEE

  13. Achilles tendon repair

    Science.gov (United States)

    ... your Achilles tendon to point your toes and push off your foot when walking. If your Achilles ... MD, Thompson SR, eds. DeLee and Drez's Orthopaedic Sports Medicine: Principles and Practice . 4th ed. Philadelphia, PA: ...

  14. Achilles Tendon Rupture

    Science.gov (United States)

    ... is a strong fibrous cord that connects the muscles in the back of your calf to your heel bone. If you overstretch your Achilles tendon, it can tear (rupture) completely or just partially. If your Achilles ...

  15. High-resolution US and MR imaging of peroneal tendon injuries.

    Science.gov (United States)

    Taljanovic, Mihra S; Alcala, Jennifer N; Gimber, Lana H; Rieke, Joshua D; Chilvers, Margaret M; Latt, L Daniel

    2015-01-01

    Injuries of the peroneal tendon complex are common and should be considered in every patient who presents with chronic lateral ankle pain. These injuries occur as a result of trauma (including ankle sprains), in tendons with preexisting tendonopathy, and with repetitive microtrauma due to instability. The peroneus brevis and peroneus longus tendons are rarely torn simultaneously. Several anatomic variants, including a flat or convex fibular retromalleolar groove, hypertrophy of the peroneal tubercle at the lateral aspect of the calcaneus, an accessory peroneus quartus muscle, a low-lying peroneus brevis muscle belly, and an os peroneum, may predispose to peroneal tendon injuries. High-resolution 1.5-T and 3-T magnetic resonance (MR) imaging with use of dedicated extremity coils and high-resolution ultrasonography (US) with high-frequency linear transducers and dynamic imaging are proved to adequately depict the peroneal tendons for evaluation and can aid the orthopedic surgeon in injury management. An understanding of current treatment approaches for partial- and full-thickness peroneal tendon tears, subluxation and dislocation of these tendons with superior peroneal retinaculum (SPR) injuries, intrasheath subluxations, and peroneal tendonopathy and tenosynovitis can help physicians achieve a favorable outcome. Patients with low functional demands do well with conservative treatment, while those with high functional demands may benefit from surgery if nonsurgical treatment is unsuccessful. Radiologists should recognize the normal anatomy and specific pathologic conditions of the peroneal tendons at US and MR imaging and understand the various treatment options for peroneal tendon and SPR superior peroneal retinaculum injuries. Online supplemental material is available for this article. RSNA, 2015

  16. Achilles tendon and sports; Die Achillessehne im Sport

    Energy Technology Data Exchange (ETDEWEB)

    Ulreich, N.; Kainberger, F. [Univ.-Klinik fuer Radiodiagnostik Wien (Austria); Huber, W.; Nehrer, S. [Univ.-Klinik fuer Orthopaedie Wien (Austria)

    2002-10-01

    Because of the rising popularity of recreational sports activities achillodynia is an often associated symptom with running, soccer and athletics. Therefore radiologist are frequently asked to image this tendon. The origin of the damage of the Achilles tendon is explained by numerous hypothesis, mainly a decreased perfusion and a mechanical irritation that lead to degeneration of the tendon. High-resolution technics such as sonography and magnetic resonance imaging show alterations in the structure of the tendon which can be graduated and classified. Manifestations like tendinosis, achillobursitis, rupture and Haglunds disease can summarized as the tendon overuse syndrom. A rupture of a tendon is mostly the result of a degeneration of the collagenfibres. The task of the radiologist is to acquire the intrinsic factors for a potential rupture. (orig.) [German] Aufgrund des starken Anstiegs des Freizeitsportes sind Achillodynien ein besonders mit Laufsport, Fussball und Leichtathletik assoziiertes Symptom und die Indikation zur radiologischen Abklaerung wird oft gestellt. Die Entstehung von Sehnenschaeden wird durch eine Reihe von Hypothesen erklaert, wobei eine gestoerte Gewebeperfusion und eine mechanische Irritation als Hauptursachen angesehen werden, die zur Degeneration des Sehnengewebes und des umgebenden Gleitlagers fuehren. Sie koennen aufgrund sonographischer und MR-tomographischer Zeichen meist klar klassifiziert und graduiert werden, wobei hochaufloesende Techniken eine wesentliche Voraussetzung fuer die subtile Analyse der Sehnenstruktur darstellen. Die einzelnen klinischen Erscheinungsformen wie Tendinose, Achillobursitis, Haglund-Ferse und Sehnenruptur koennen unter dem Begriff des ''Sehnenueberlastungssyndroms'' (Tendon overuse syndrome) subsummiert werden. Rupturen der Achillessehne treten so gut wie immer bei bereits vorgeschaedigtem Kollagenfasergewebe auf, und der radiologischen Diagnostik kommt wesentliche Bedeutung dabei zu

  17. Simulation of tendon energy storage in pedaling

    DEFF Research Database (Denmark)

    Rasmussen, John; Damsgaard, Michael; Christensen, Søren Tørholm

    2001-01-01

    The role of elastic energy stored in tendons during pedaling is investigated by means of numerical simulation using the AnyBody body modeling system. The loss of metabolic energy due to tendon elasticity is computed and compared to the mechanical work involved in the process. The AnyBody simulati...

  18. Structural and Ultrastructural Characteristics of Bone-Tendon Junction of the Calcaneal Tendon of Adult and Elderly Wistar Rats

    Science.gov (United States)

    Cury, Diego Pulzatto; Dias, Fernando José; Miglino, Maria Angélica; Watanabe, Ii-sei

    2016-01-01

    Tendons are transition tissues that transfer the contractile forces generated by the muscles to the bones, allowing movement. The region where the tendon attaches to the bone is called bone-tendon junction or enthesis and may be classified as fibrous or fibrocartilaginous. This study aims to analyze the collagen fibers and the cells present in the bone-tendon junction using light microscopy and ultrastructural techniques as scanning electron microscopy and transmission electron microscopy. Forty male Wistar rats were used in the experiment, being 20 adult rats at 4 months-old and 20 elderly rats at 20 months-old. The hind limbs of the rats were removed, dissected and prepared to light microscopy, transmission electron microscopy and scanning electron microscopy. The aging process showed changes in the collagen fibrils, with a predominance of type III fibers in the elderly group, in addition to a decrease in the amount of the fibrocartilage cells, fewer and shorter cytoplasmic processes and a decreased synthetic capacity due to degradation of the organelles involved in synthesis. PMID:27078690

  19. Structural and Ultrastructural Characteristics of Bone-Tendon Junction of the Calcaneal Tendon of Adult and Elderly Wistar Rats.

    Directory of Open Access Journals (Sweden)

    Diego Pulzatto Cury

    Full Text Available Tendons are transition tissues that transfer the contractile forces generated by the muscles to the bones, allowing movement. The region where the tendon attaches to the bone is called bone-tendon junction or enthesis and may be classified as fibrous or fibrocartilaginous. This study aims to analyze the collagen fibers and the cells present in the bone-tendon junction using light microscopy and ultrastructural techniques as scanning electron microscopy and transmission electron microscopy. Forty male Wistar rats were used in the experiment, being 20 adult rats at 4 months-old and 20 elderly rats at 20 months-old. The hind limbs of the rats were removed, dissected and prepared to light microscopy, transmission electron microscopy and scanning electron microscopy. The aging process showed changes in the collagen fibrils, with a predominance of type III fibers in the elderly group, in addition to a decrease in the amount of the fibrocartilage cells, fewer and shorter cytoplasmic processes and a decreased synthetic capacity due to degradation of the organelles involved in synthesis.

  20. Revision with suture-tape augmentation after failed collateral ligament reconstruction for chronic interphalangeal instability of the hallux.

    Science.gov (United States)

    Cho, Byung-Ki; Park, Ji-Kang; Choi, Seung-Myung; SooHoo, Nelson F

    2017-12-01

    Chronic varus instability or recurrent subluxation following isolated interphalangeal dislocation of the hallux is a rare injury. No consensus has been reached regarding the best joint-salvage procedure for patients with the failed collateral ligament reconstruction using tendon graft. We report a case who achieved satisfactory clinical outcome through a modified surgical procedure (revision collateral ligament reconstruction augmented with suture-tape). Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  1. PERONEAL TENDON LESIONS IN ATHLETES (REVIEW

    Directory of Open Access Journals (Sweden)

    E. E. Achkasov

    2016-01-01

    Full Text Available The authors analyzed scientific literature in respect of various issues in treatment of athletes with peroneal muscles lesions starting from 1987 till 2016. Key search and publications selection was made in PubMed and russian national electronic scientific library eLIBRARY. Peroneal tendons pathology is not the major but the underestimated cause of pain in lateral and hindfoot as well as of foot dysfunction which is difficult to distinguish from lesions of lateral ligaments of the ankle joint. Untreated lesions of peroneal tendons can result in chronic ankle pain and significant functional disorders. The purpose of the present paper is to improve the current comprehension of anatomy, to identify factors contributing to pathology, to perform diagnostic evaluation of peroneal tendons and to review current treatment options of such lesions.

  2. Presence of a long accessory flexor tendon of the toes in surgical treatment for tendinopathy of the insertion of the calcaneal tendon: case report

    Directory of Open Access Journals (Sweden)

    Nelson Pelozo Gomes Júnior

    2016-02-01

    Full Text Available ABSTRACT The presence of accessory tendons in the foot and ankle needs to be recognized, given that depending on their location, they may cause disorders relating either to pain processes or to handling of the surgical findings. We describe the presence of an accessory flexor tendon of the toes, seen in surgical exposure for transferring the long flexor tendon of the hallux to the calcaneus, due to the presence of a disorder of tendinopathy of the insertion of the calcaneal tendon in association with Haglund's syndrome.

  3. Modified rerouting procedure for failed peroneal tendon dislocation surgery.

    Science.gov (United States)

    Gaulke, R; Hildebrand, F; Panzica, M; Hüfner, T; Krettek, C

    2010-04-01

    Recurrent dislocation of the peroneal tendons following operative treatment is relatively uncommon, but can be difficult to treat. We asked whether subligamental transposition of the peroneus brevis tendon, fibular grooving, and reattachment of the superior peroneal retinaculum for failed peroneal tendon dislocation surgery would achieve a stable fixation of the peroneal tendons and whether there would be restrictions of ROM or instability of the hindfoot. We reviewed six female patients (mean age, 24.5 years) with general laxity of joints preoperatively and at 6 weeks and 3, 6, and 12 months postoperatively. Within 1 year postoperatively no recurrence was found. In two ankles the extension was restricted 5 degrees to 10 degrees . In another pronation and supination was restricted 5 degrees each. Stability of the ankle increased in four patients and stayed unchanged in two. AOFAS score increased from a mean value of 36 +/- 20.6 preoperatively to 90 +/- 7 postoperatively at 1 year. We conclude transposition of the peroneus brevis tendon is a reasonable treatment for failed peroneal tendon dislocation surgery. Level IV, therapeutic study (prospective case series). See Guidelines for Authors for a complete description of levels of evidence.

  4. Disorders of the long head of the biceps tendon.

    Science.gov (United States)

    Sethi, N; Wright, R; Yamaguchi, K

    1999-01-01

    Without a clear understanding of the functional role of the biceps tendon, treatment recommendations have been a subject of controversy. An objective review of the available information would suggest that some humeral head stability may be imparted through the tendon. However, the magnitude of this function is likely to be small and possibly insignificant. In contrast, the symptomatic significance of the long head of the biceps is less controversial, and it has become increasingly recognized as an important source of persistent shoulder pain when not specifically addressed. When present, persistent pain from the long head of the biceps is likely to have more negative functional consequences than loss of the tendon itself. Given these concerns, evaluation and treatment of patients with long head of the biceps disorders should be individualized, based on the likelihood that biceps-related pain will resolve. Although not universally accepted, we recommend tenodesis of the long head of the biceps in those cases in which there are either chronic inflammatory or structural changes, which would make it unlikely that the pain would resolve. These clinical situations in which tenodesis would be required include greater than 25% partial thickness tearing of the tendon, chronic atrophic changes of the tendon, any luxation of the biceps tendon from the bicipital groove, any disruption of associated bony or ligamentous anatomy of the bicipital groove that would make autotenodesis likely (i.e., 4-part fracture), and any significant reduction or atrophy of the size of the tendon that is more than 25% of the normal tendon width. Relative indications for biceps tenodesis also include biceps disease in the context of a failed decompression for rotator cuff tendinitis. It should be emphasized that routine tenodesis is not recommended during operative treatment for the rotator cuff. Rather, we avoid tenodesis whenever it is believed that inflammatory changes to the biceps tendon are

  5. Immediate postoperative anterior knee stability: double- versus triple-bundle anterior cruciate ligament reconstructions.

    Science.gov (United States)

    Mae, Tatsuo; Shino, Konsei; Matsumoto, Norinao; Yoneda, Kenji; Yoshikawa, Hideki; Nakata, Ken

    2013-02-01

    The purpose of this study was to compare the triple-bundle (TB) anterior cruciate ligament (ACL) reconstruction with the double-bundle (DB) ACL reconstruction in immediate postoperative anterior knee stability. This study involved 133 patients who had undergone the anatomic ACL reconstruction with autogenous hamstring tendon unilaterally. Then 83 patients (mean age, 28.8 years) underwent the DB between November 2004 and December 2005, and 50 patients (mean age, 29.6 years) underwent the TB ACL reconstruction between January and December 2006. The 2 femoral tunnels were created in the ideal ACL attachment area, whereas 2 tibial tunnels for the DB and 3 tunnels for the TB were created in the ACL footprint. The 2 doubled tendon grafts were fixed with EndoButton-CL (Smith & Nephew Endoscopy, Andover, MA) on the femur. The grafts were fixed to the tibia using a Double Spike Plate and a screw under the total initial tension of 20 N at 20° of flexion, after meticulous in situ pretensioning using a tensioning boot. Then immediate postoperative anterior knee laxity in response to 89 N of anterior load was measured by one experienced examiner (T.M.) with the KT-2000 Knee Arthrometer (MEDmedtric, San Diego, CA) under general anesthesia at 30° of knee flexion with muscle relaxants. The measured anterior laxity was 3.4 ± 1.2 mm in the DB and 2.5 ± 0.7 mm in the TB ACL reconstruction, a statistically significant difference. The side-to-side difference of the laxity was -3.2 ± 1.6 mm in the DB and -4.2 ± 2.0 mm in the TB, again a significant difference. TB ACL reconstruction resulted in better immediate postoperative anterior knee stability than DB ACL reconstruction under 89 N of anterior tibial load (P = .031). Level III, therapeutic retrospective comparative study. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  6. Achilles tendon of wistar rats treated with laser therapy and eccentric exercise

    Directory of Open Access Journals (Sweden)

    Maria Verônica de Souza

    2015-10-01

    Full Text Available ABSTRACTIntroduction:Both laser therapy and eccentric exercises are used in tendon injuries. However, the association of these physiotherapeutic modalities is yet little investigated.Objective:To evaluate the effect of low-level laser therapy associated to eccentric exercise (downhill walking on Achilles tendinopathy of Wistar rats.Method:Eighteen Achilles tendon from 15 adult male Wistar rats were used. Tendons were distributed in six groups (laser, eccentric exercise, laser and eccentric exercise, rest, contralateral tendon, and healthy tendon. Unilateral tendinopathy was surgically induced by transversal compression followed by scarification of tendon fibers. The treatments laser therapy (904 nm, 3J/cm² and/or eccentric exercise (downhill walking; 12 m/min; 50 min/day; 15o inclination treadmill began 24 hours after surgery and remained for 20 days. Clinical and biomechanical analyzes were conducted. Achilles tendon was macroscopically evaluated and the transversal diameter measured. Euthanasia was performed 21 days after lesion induction. Tendons of both limbs were collected and frozen at -20°C until biomechanical analysis, on which the characteristic of maximum load (N, stress at ultimate (MPa and maximum extension (mm were analyzed.Results:Swelling was observed within 72 hours postoperative. No fibrous adhesions were observed nor increase in transversal diameter of tendons. Animals with the exercised tendons, but not treated with laser therapy, presented lower (p=0.0000 locomotor capacity. No difference occurred be-tween groups for the biomechanical characteristics maximum load (p=0.4379, stress at ultimate (p=0.4605 and maximum extension (p=0.3820 evaluated, even considering healthy and contralateral tendons.Conclusion:The concomitant use of low-level laser and the eccentric exercise of downhill walking, starting 24 hours after surgically induced tendinopathy, do not result in a tendon with the same biomechanical resistance or elasticity

  7. triceps tendon avulsion

    African Journals Online (AJOL)

    GB

    2014-01-01

    Jan 1, 2014 ... trauma. Systemic causes such as chronic renal failure, steriod use, diabetes mellitus, hyperparathyroidism, rheumatoid arthritis, osteogensis imperfecta and local causes like local steriod injection, olecranon bursitis and attritional changes due to degenerative arthritis are associated with tendon weakening.

  8. Final report on PCRV thermal cylinder axial tendon failures

    International Nuclear Information System (INIS)

    Canonico, D.A.; Griess, J.C.; Robinson, G.C.

    1976-01-01

    The post-test examination of the failed tendons from the PCRV thermal cylinder experiment has been concluded. Failures in the wires are attributed to stress-corrosion cracking. The cause of tendon failures has not been unequivocably established, but they may have been due to nitrates in the duct. The wires employed in the manufacture of the tendons will crack in less than 72 hr in a 0.2 M solution of ammonium nitrate at 70 0 C. The quality of the wires is poor, and surface cracks were detected. These could have acted as concentrating sites for both stress and the deleterious contaminants. It is believed that the factors that led to the failures in the thermal cylinder experiment were unique. An improper formulation of the epoxy resin did not provide the tendon anchor plate seal that was desired; indeed, the improper formulation is responsible for the high level of nitrogen in the ducts of the failed tendons

  9. Schwann cell seeded guidance tubes restore erectile function after ablation of cavernous nerves in rats.

    Science.gov (United States)

    May, F; Weidner, N; Matiasek, K; Caspers, C; Mrva, T; Vroemen, M; Henke, J; Lehmer, A; Schwaibold, H; Erhardt, W; Gänsbacher, B; Hartung, R

    2004-07-01

    Dissection of the cavernous nerves eliminates spontaneous erections. We evaluated the ability of Schwann cell seeded nerve guidance tubes to restore erections after bilateral cavernous nerve resection in rats. Sections (5 mm) of the cavernous nerve were excised bilaterally, followed by immediate bilateral microsurgical reconstruction. In 10 animals per group (20 study nerves) reconstruction was performed by genitofemoral nerve interposition, interposition of silicone tubes or interposition of silicone tubes seeded with homologous Schwann cells. As the control 10 animals (20 study nerves) underwent sham operation (positive control) and bilateral nerve ablation (without reconstruction) was performed in a further 10 (negative control). Erectile function was evaluated 3 months postoperatively by relaparotomy, electrical nerve stimulation and intracavernous pressure recording. After 3 months neurostimulation resulted in an intact erectile response in 90% (18 of 20) of Schwann cell grafts, while treatment with autologous nerves (30% or 6 of 20) or tubes only (50% or 10 of 20) was less successful (p Schwann cell grafts compared to results in the other treatment groups (p Schwann cell grafts. Schwann cell seeded guidance tubes restore erectile function after the ablation of cavernous nerves in rats and they are superior to autologous nerve grafts.

  10. Dextrose prolotherapy and corticosteroid injection into rat Achilles tendon.

    Science.gov (United States)

    Martins, C A Q; Bertuzzi, R T; Tisot, R A; Michelin, A F; do Prado, J M; Stroher, A; Burigo, M

    2012-10-01

    To assess the mechanical behavior and the histology of collagen fibers after prolotherapy with 12.5% dextrose into rat Achilles tendons and to compare with those of corticosteroid treatment. Out of 60 adult female Wistar rats (70 tendons), 15 received 12.5% dextrose (group I); 15 were treated with corticosteroid injection (group II); and 15 were given 0.9% saline injection (group III), all into the right Achilles tendon, whereas 13 animals received no injections (group IV). Three doses of each substance (groups I, II, and III) were given at a 5-day interval. Collagen fiber color was quantitatively assessed in three samples from each group and in five samples from the control group using picrosirius red staining under polarized and nonpolarized light. Twelve tendons from each group treated with the test substance and 20 tendons from the control group were submitted to the tensile strength test. There was no statistical difference across the groups with respect to maximum load at failure (n.s.) and absorbed energy (n.s.). With respect to tendon rupture, there was no difference between the myotendinous and the tendinous regions (n.s.). However, hematoxylin-eosin staining revealed statistical significance in lymphocytic inflammatory infiltrate (P = 0.008) and in parallel fiber orientation (P = 0.003) when comparing groups to the control group, without significance for either neovascularization (n.s.) or the presence of fibroblasts (n.s.). Likewise, there was no significant difference between the percentage of mature (n.s.) and immature (n.s.) fibers. Dextrose was not deleterious to the tendinous tissue, as it did not change the mechanical and histological properties of Achilles tendons in rats. The data obtained in this study may help clinicians in their daily work as they suggest that injections of 12.5% dextrose caused no harm to the tendons, although the clinical importance in humans still needs to be defined.

  11. Construction of a Jejunal Pouch After Total Gastrectomy

    African Journals Online (AJOL)

    food intake and slow the transit. Reconstruction using a jejunal interposition is more complicated and less suitable than the simple classic Roux‑en‑Y reconstruction.[1]. According to several prospective randomized trials and a recent meta‑analysis, the Roux‑en‑Y jejunal pouch reconstruction [Figure 1] appears to be the ...

  12. Triple Achilles Tendon Rupture: Case Report.

    Science.gov (United States)

    Saxena, Amol; Hofer, Deann

    We present a case report with 1-year follow-up data of a 57-year-old male soccer referee who had sustained an acute triple Achilles tendon rupture injury during a game. His triple Achilles tendon rupture consisted of a rupture of the proximal watershed region, a rupture of the main body (mid-watershed area), and an avulsion-type rupture of insertional calcific tendinosis. The patient was treated surgically with primary repair of the tendon, including tenodesis with anchors. Postoperative treatment included non-weightbearing for 4 weeks and protected weightbearing until 10 weeks postoperative, followed by formal physical therapy, which incorporated an "antigravity" treadmill. The patient was able to return to full activity after 26 weeks, including running and refereeing, without limitations. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Ultrasound elasticity imaging of human posterior tibial tendon

    Science.gov (United States)

    Gao, Liang

    Posterior tibial tendon dysfunction (PTTD) is a common degenerative condition leading to a severe impairment of gait. There is currently no effective method to determine whether a patient with advanced PTTD would benefit from several months of bracing and physical therapy or ultimately require surgery. Tendon degeneration is closely associated with irreversible degradation of its collagen structure, leading to changes to its mechanical properties. If these properties could be monitored in vivo, it could be used to quantify the severity of tendonosis and help determine the appropriate treatment. Ultrasound elasticity imaging (UEI) is a real-time, noninvasive technique to objectively measure mechanical properties in soft tissue. It consists of acquiring a sequence of ultrasound frames and applying speckle tracking to estimate displacement and strain at each pixel. The goals of my dissertation were to 1) use acoustic simulations to investigate the performance of UEI during tendon deformation with different geometries; 2) develop and validate UEI as a potentially noninvasive technique for quantifying tendon mechanical properties in human cadaver experiments; 3) design a platform for UEI to measure mechanical properties of the PTT in vivo and determine whether there are detectable and quantifiable differences between healthy and diseased tendons. First, ultrasound simulations of tendon deformation were performed using an acoustic modeling program. The effects of different tendon geometries (cylinder and curved cylinder) on the performance of UEI were investigated. Modeling results indicated that UEI accurately estimated the strain in the cylinder geometry, but underestimated in the curved cylinder. The simulation also predicted that the out-of-the-plane motion of the PTT would cause a non-uniform strain pattern within incompressible homogeneous isotropic material. However, to average within a small region of interest determined by principal component analysis (PCA

  14. Treatment of peroneal nerve injuries with simultaneous tendon transfer and nerve exploration.

    Science.gov (United States)

    Ho, Bryant; Khan, Zubair; Switaj, Paul J; Ochenjele, George; Fuchs, Daniel; Dahl, William; Cederna, Paul; Kung, Theodore A; Kadakia, Anish R

    2014-08-06

    Common peroneal nerve palsy leading to foot drop is difficult to manage and has historically been treated with extended bracing with expectant waiting for return of nerve function. Peroneal nerve exploration has traditionally been avoided except in cases of known traumatic or iatrogenic injury, with tendon transfers being performed in a delayed fashion after exhausting conservative treatment. We present a new strategy for management of foot drop with nerve exploration and concomitant tendon transfer. We retrospectively reviewed a series of 12 patients with peroneal nerve palsies that were treated with tendon transfer from 2005 to 2011. Of these patients, seven were treated with simultaneous peroneal nerve exploration and repair at the time of tendon transfer. Patients with both nerve repair and tendon transfer had superior functional results with active dorsiflexion in all patients, compared to dorsiflexion in 40% of patients treated with tendon transfers alone. Additionally, 57% of patients treated with nerve repair and tendon transfer were able to achieve enough function to return to running, compared to 20% in patients with tendon transfer alone. No patient had full return of native motor function resulting in excessive dorsiflexion strength. The results of our limited case series for this rare condition indicate that simultaneous nerve repair and tendon transfer showed no detrimental results and may provide improved function over tendon transfer alone.

  15. Flexor Tendon Injuries

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... fields From * To * DESCRIPTION The muscles that bend (flex) the fingers are called flexor ...

  16. Tendinopathy of the long head of the biceps tendon: histopathologic analysis of the extra-articular biceps tendon and tenosynovium

    Directory of Open Access Journals (Sweden)

    Streit JJ

    2015-03-01

    Full Text Available Jonathan J Streit,1 Yousef Shishani,1 Mark Rodgers,2 Reuben Gobezie1 1The Cleveland Shoulder Institute, 2Department of Pathology, University Hospitals of Cleveland, Cleveland, OH, USA Background: Bicipital tendinitis is a common cause of anterior shoulder pain, but there is no evidence that acute inflammation of the extra-articular long head of the biceps (LHB tendon is the root cause of this condition. We evaluated the histologic findings of the extra-articular portion of the LHB tendon and synovial sheath in order to compare those findings to known histologic changes seen in other tendinopathies. Methods: Twenty-six consecutive patients (mean age 45.4±13.7 years underwent an open subpectoral biceps tenodesis for anterior shoulder pain localized to the bicipital groove. Excised tendons were sent for histologic analysis. Specimens were graded using a semiquantitative scoring system to evaluate tenocyte morphology, the presence of ground substance, collagen bundle characteristics, and vascular changes. Results: Chronic inflammation was noted in only two of 26 specimens, and no specimen demonstrated acute inflammation. Tenocyte enlargement and proliferation, characterized by increased roundness and size of the cell and nucleus with proteoglycan matrix expansion and myxoid degenerative changes, was found in all 26 specimens. Abundant ground substance, collagen bundle changes, and increased vascularization were visualized in all samples. Conclusion: Anterior shoulder pain attributed to the biceps tendon does not appear to be due to an inflammatory process in most cases. The histologic findings of the extra-articular portion of the LHB tendon and synovial sheath are similar to the pathologic findings in de Quervain tenosynovitis at the wrist, and may be due to a chronic degenerative process similar to this and other tendinopathies of the body. Keywords: biceps tendinitis, biceps tendinopathy, tenosynovium, anterior shoulder pain, long head biceps

  17. [Application of silk-based tissue engineering scaffold for tendon / ligament regeneration].

    Science.gov (United States)

    Hu, Yejun; Le, Huihui; Jin, Zhangchu; Chen, Xiao; Yin, Zi; Shen, Weiliang; Ouyang, Hongwei

    2016-03-01

    Tendon/ligament injury is one of the most common impairments in sports medicine. The traditional treatments of damaged tissue repair are unsatisfactory, especially for athletes, due to lack of donor and immune rejection. The strategy of tissue engineering may break through these limitations, and bring new hopes to tendon/ligament repair, even regeneration. Silk is a kind of natural biomaterials, which has good biocompatibility, wide range of mechanical properties and tunable physical structures; so it could be applied as tendon/ligament tissue engineering scaffolds. The silk-based scaffold has robust mechanical properties; combined with other biological ingredients, it could increase the surface area, promote more cell adhesion and improve the biocompatibility. The potential clinical application of silk-based scaffold has been confirmed by in vivo studies on tendon/ligament repairing, such as anterior cruciate ligament, medial collateral ligament, achilles tendon and rotator cuff. To develop novel biomechanically stable and host integrated tissue engineered tendon/ligament needs more further micro and macro studies, combined with product development and clinical application, which will give new hope to patients with tendon/ligament injury.

  18. The "Parachute" Technique: A Simple and Effective Single-Row Procedure to Achieve an Increased Contact Area Between the Cuff-Tendon and Its Footprint.

    Science.gov (United States)

    Natera, Luis; Consigliere, Paolo; Witney-Lagen, Caroline; Brugera, Juan; Sforza, Giuseppe; Atoun, Ehud; Levy, Ofer

    2017-10-01

    Many techniques of arthroscopic rotator cuff repair have been described. No significant differences in clinical outcomes or rerupture rates have been observed when comparing single-row with double-row methods. Not all single- and double-row repairs are the same. The details of the technique used are crucial. It has been shown that the suture-tendon interface is the weakest point of the reconstruction. Therefore, the biomechanical properties of rotator cuff repairs might be influenced more by the suture configuration than by the number of anchors or by the number of rows involved. Techniques that secure less amount of tendon over a smaller area of the healing zone might be expected to have higher failure rates. The way the sutures of the "parachute technique" are configured represents a quadruple mattress that increases the contact and pressure between the tendon and its footprint and increases the primary load to failure of the repair. We present a simple and effective single-row technique that involves the biomechanical and biological advantages related to the increased contact area and pressure between the cuff and its footprint.

  19. The effect of irradiation and hydration upon the mechanical properties of tendon

    International Nuclear Information System (INIS)

    Smith, C.W.; Kearney, J.N.

    1996-01-01

    Irradiation sterilization is in wide use among tissue banks, for both hard and soft tissue grafts. Irradiation of tendon can impair its mechanical properties. Following implantation of a tendon graft, re-vascularization and resorption processes reduce its mechanical performance. Tendon with severely impaired properties may not be suitable for use as a load-bearing graft, e.g. as anterior cruciate ligament replacement. An important factor determining the extent of the reduction of the mechanical performance is the condition of the tendon during irradiation, especially the presence of water. There has not yet been a study of the effects of both irradiation dose and hydration on tendon mechanical properties. This study measured the changes in tensile mechanical properties, including strength and stiffness, following γ irradiation doses of 15 kGy (1.5 MRad) and 25 kGy irradiated tendons was lower compared to fresh tendons, whereas the strength of the frozen irradiated tendons was very similar to that of the fresh. The tangent modulus of both of the freeze-dried irradiated groups were lower than the fresh tendons, as was the 15 kGy frozen group. The modulus of the 25 kGy frozen irradiated group was similar to the fresh. The general pattern of the results indicate that the two freeze-dried tendon groups were more affected than the frozen irradiated, and of the frozen irradiated groups the 25 kGy group was least affected. The results fit well with suggested mechanisms for the action of irradiation upon collagen; that intramolecular crosslinking and scission of the tropocollagen α chains occur when water is present, and α chain scission alone occurs when water is absent. Irradiation of tendons for use as grafts may produce minimal deleterious changes if the irradiation is performed while the tendon is frozen with water present. (Author)

  20. No Telescoping Effect with Dual Tendon Vibration.

    Directory of Open Access Journals (Sweden)

    Valeria Bellan

    Full Text Available The tendon vibration illusion has been extensively used to manipulate the perceived position of one's own body part. However, findings from previous research do not seem conclusive sregarding the perceptual effect of the concurrent stimulation of both agonist and antagonist tendons over one joint. On the basis of recent data, it has been suggested that this paired stimulation generates an inconsistent signal about the limb position, which leads to a perceived shrinkage of the limb. However, this interesting effect has never been replicated. The aim of the present study was to clarify the effect of a simultaneous and equal vibration of the biceps and triceps tendons on the perceived location of the hand. Experiment 1 replicated and extended the previous findings. We compared a dual tendon stimulation condition with single tendon stimulation conditions and with a control condition (no vibration on both 'upward-downward' and 'towards-away from the elbow' planes. Our results show a mislocalisation towards the elbow of the position of the vibrated arm during dual vibration, in line with previous results; however, this did not clarify whether the effect was due to arm representation contraction (i.e., a 'telescoping' effect. Therefore, in Experiment 2 we investigated explicitly and implicitly the perceived arm length during the same conditions. Our results clearly suggest that in all the vibration conditions there was a mislocalisation of the entire arm (including the elbow, but no evidence of a contraction of the perceived arm length.

  1. Ultrasonographic Tendon Alteration in Relation to Parathyroid Dysfunction in Chronic Hemodialysis Patients

    Directory of Open Access Journals (Sweden)

    Dahlia A. Hussein

    2015-01-01

    Full Text Available Objective To find the nature of tendon involvement in chronic kidney disease (CKD patients on regular hemodialysis (RD, and its relationship to parathyroid hormone (PTH level using ultrasonography (US. Method A total of 50 CKD patients on RD subjected to musculoskeletal examination of knee and ankle, laboratory evaluation, and US of quadriceps tendon and Achilles tendon were involved. Results Ankle joint tenderness was the most frequent sign on examination. US of the Achilles tendons showed tenderness during probing in 44% patients, calcific deposition in 24% patients, abnormal peritendon tissue in 20% patients, and abnormal anteroposterior (A-P middle and distal one-third thicknesses of the Achilles tendon in 20% and 18% patients, respectively. PTH positively correlated with the duration of dialysis, serum phosphorus level, presence of calcific deposit, and increased thickness of the Achilles tendon. Conclusion The most common ultrasonographic finding in CKD patients on RD was Achilles tendon tenderness during probing. PTH level positively correlated with the duration of dialysis, presence of calcific deposit, and increased thickness of Achilles tendon.

  2. Dynamic ultrasound of peroneal tendon instability.

    Science.gov (United States)

    Pesquer, Lionel; Guillo, Stéphane; Poussange, Nicolas; Pele, Eric; Meyer, Philippe; Dallaudière, Benjamin

    2016-07-01

    Ankle snapping may be caused by peroneal tendon instability. Anterior instability occurs after traumatic superior peroneal retinaculum injury, whereas peroneal tendon intrasheath subluxation is atraumatic. Whereas subluxation is mainly dynamic, ultrasound allows for the diagnosis and classification of peroneal instability because it allows for real-time exploration. The purpose of this review is to describe the anatomic and physiologic bases for peroneal instability and to heighten the role of dynamic ultrasound in the diagnosis of snapping.

  3. Calcitonin effect on Achilles tendon healing. An experimental study on rabbits.

    Science.gov (United States)

    Petrou, C G; Karachalios, T S; Khaldi, L; Karantanas, A H; Lyritis, G P

    2009-01-01

    A positive potential effect of Calcitonin (CT) on Achilles tendon healing was investigated as well as the ability of MRI to follow the tendon healing process. A standardized tenotomy of the Achilles tendon was performed on forty-two rabbits. Twenty-one animals received daily 21 IU /kg Calcitonin intramuscularly (treatment group CT) during the experiment and the remaining received saline solution (control group P). Seven animals from each group were killed at one, two and three weeks postoperatively. All animals had serial MRI scans and tendon samples underwent biomechanical and histological testing. For both groups, animals of the same subgroup showed statistically significant difference in signal intensity values of MRI between the 1st and 3rd week (pTendon samples from group CT showed statistically significant difference in ultimate tensile strength compared to controls at 2 (ptendon healing stages. It is suggested that Calcitonin enhances Achilles tendon healing process.

  4. Characterization of differential properties of rabbit tendon stem cells and tenocytes

    Directory of Open Access Journals (Sweden)

    Wang James

    2010-01-01

    Full Text Available Abstract Background Tendons are traditionally thought to consist of tenocytes only, the resident cells of tendons; however, a recent study has demonstrated that human and mouse tendons also contain stem cells, referred to as tendon stem/progenitor cells (TSCs. However, the differential properties of TSCs and tenocytes remain largely undefined. This study aims to characterize the properties of these tendon cells derived from rabbits. Methods TSCs and tenocytes were isolated from patellar and Achilles tendons of rabbits. The differentiation potential and cell marker expression of the two types of cells were examined using histochemical, immunohistochemical, and qRT-PCR analysis as well as in vivo implantation. In addition, morphology, colony formation, and proliferation of TSCs and tenocytes were also compared. Results It was found that TSCs were able to differentiate into adipocytes, chondrocytes, and osteocytes in vitro, and form tendon-like, cartilage-like, and bone-like tissues in vivo. In contrast, tenocytes had little such differentiation potential. Moreover, TSCs expressed the stem cell markers Oct-4, SSEA-4, and nucleostemin, whereas tenocytes expressed none of these markers. Morphologically, TSCs possessed smaller cell bodies and larger nuclei than ordinary tenocytes and had cobblestone-like morphology in confluent culture whereas tenocytes were highly elongated. TSCs also proliferated more quickly than tenocytes in culture. Additionally, TSCs from patellar tendons formed more numerous and larger colonies and proliferated more rapidly than TSCs from Achilles tendons. Conclusions TSCs exhibit distinct properties compared to tenocytes, including differences in cell marker expression, proliferative and differentiation potential, and cell morphology in culture. Future research should investigate the mechanobiology of TSCs and explore the possibility of using TSCs to more effectively repair or regenerate injured tendons.

  5. Comparative anatomy of rabbit and human achilles tendons with magnetic resonance and ultrasound imaging.

    Science.gov (United States)

    Doherty, Geoffrey P; Koike, Yoichi; Uhthoff, Hans K; Lecompte, Martin; Trudel, Guy

    2006-02-01

    We sought to describe the comparative anatomy of the Achilles tendon in rabbits and humans by using macroscopic observation, magnetic resonance imaging, and ultrasonography. The calcaneus-Achilles tendon-gastrocnemius-soleus complexes from 18 New Zealand white rabbits underwent ultrasound (US) and magnetic resonance (MR) imaging and gross anatomic sectioning; these results were compared with those from a cadaveric gastrocnemius-soleus-Achilles tendon-calcaneus specimen from a 68-y-old human male. The medial and lateral gastrocnemius muscle tendons merged 5.2 +/- 0.6 mm proximal to the calcaneal insertion macroscopically, at 93% of their course, different from the gastrocnemius human tendons, which merged at 23% of their overall course. The rabbit flexor digitorum superficialis tendon, corresponding to the flexor digitorum longus tendon in human and comparable in size with the gastrocnemius tendons, was located medial and anterior to the medial gastrocnemius tendon proximally and rotated dorsally and laterally to run posterior to the Achilles tendon-calcaneus insertion. In humans, the flexor digitorum longus tendon tracks posteriorly to the medial malleolus. The soleus muscle and tendon are negligible in the rabbit; these particular comparative anatomic features in the rabbit were confirmed on the MR images. Therefore the rabbit Achilles tendon shows distinctive gross anatomical and MR imaging features that must be considered when using the rabbit as a research model, especially for mechanical testing, or when generalizing results from rabbits to humans.

  6. A new barbed device for repair of flexor tendons.

    LENUS (Irish Health Repository)

    Hirpara, K M

    2012-02-01

    We split 100 porcine flexor tendons into five groups of 20 tendons for repair. Three groups were repaired using the Pennington modified Kessler technique, the cruciate or the Savage technique, one using one new device per tendon and the other with two new devices per tendon. Half of the tendons received supplemental circumferential Silfverskiold type B cross-stitch. The repairs were loaded to failure and a record made of their bulk, the force required to produce a 3 mm gap, the maximum force applied before failure and the stiffness. When only one device was used repairs were equivalent to the Pennington modified Kessler for all parameters except the force to produce a 3 mm gap when supplemented with a circumferential repair, which was equivalent to the cruciate. When two devices were used the repair strength was equivalent to the cruciate repair, and when the two-device repair was supplemented with a circumferential suture the force to produce a 3 mm gap was equivalent to that of the Savage six-strand technique.

  7. Anti-inflammatory management for tendon injuries - friends or foes?

    Directory of Open Access Journals (Sweden)

    Chan Kai-Ming

    2009-10-01

    Full Text Available Abstract Acute and chronic tendon injuries are very common among athletes and in sedentary population. Most physicians prescribe anti-inflammatory managements to relieve the worst symptoms of swelling and pain, including non-steroidal anti-inflammatory drugs, corticosteroids and physical therapies. However, experimental research shows that pro-inflammatory mediators such as prostaglandins may play important regulatory roles in tendon healing. Noticeably nearly all cases of chronic tendon injuries we treat as specialists have received non-steroidal anti-inflammatory drugs by their physician, suggesting that there might be a potential interaction in some of these cases turning a mild inflammatory tendon injury into chronic tendinopathy in predisposed individuals. We are aware of the fact that non-steroidal anti-inflammatory drugs and corticosteroids may well have a positive effect on the pain control in the clinical situation whilst negatively affect the structural healing. It follows that a comprehensive evaluation of anti-inflammatory management for tendon injuries is needed and any such data would have profound clinical and health economic importance.

  8. Morpho-functional changes in human tendon tissue

    Directory of Open Access Journals (Sweden)

    I Galliani

    2009-12-01

    Full Text Available Insertion tissue biopsies of right arm common extensor tendons from 11 patients with chronic lateral epicondylitis were processed for light and electron microscopy. The subjects were aged between 38 and 54 years (only one was 25. The specimens showed a variety of structural changes such as biochemical and spatial alteration of collagen, hyaline degeneration, loss of tenocytes, fibrocartilage metaplasia, calcifying processes, neovascularization and vessel wall modifications. Tissue alterations were evident in limited zones of the tendon fibrocartilage in which the surgical resection was generally visible. The areas where the degenerative processes were localized, were restricted and in spatial contiguity with morphologically normal ones. The observed cases presented histological and electron microscopic findings that characterize lateral epicondylitis as a degenerative phenomenon involving all tendon components.

  9. [The history of flexor tendon surgery].

    Science.gov (United States)

    Chamay, A

    1997-01-01

    Flexor tendon injuries were already treated in antiquity by Hippocrates, Galien and Avicenne. Since the Renaissance, other surgeons have attempted to repair flexor tendon injuries, but without success due to problems related to unsuitable materials and ignorance of the basic rules of asepsis and the absence of antiseptics until the second half of the 19th century. The first successful flexor tendon grafts in man were performed by K. Biesalski in 1910, E. Lexer in 1912 and L. Mayer in 1916. These three authors published their series of grafts and described in detail the anatomical, physiological and technical principles to be respected. St. Bunnell, in 1918, developed various pull-out direct suture procedures, but faced with the problems of adhesions, he abandoned this technique and proposed not to repair flexors in the digital tunnels but to graft them. He defined the famous zone which he called No man's land, which subsequently became Claude Verdan's zone II, in 1959. In 1960, C. Verdan published his first series of sutures maintained by 2 pins in zone II with comparable results to those obtained after grafting. In 1967, H. Kleinert, with his mobile suture, became the leader of direct tendon repair in zone II. 2-stage grafts were introduced in 1965 under the impetus of J. Hunter, who revised and popularized the studies conducted by A. Bassett and R.E. Caroll in 1950.

  10. The Prevalence and Role of Low Lying Peroneus Brevis Muscle Belly in Patients with Peroneal Tendon Pathologies: A Potential Source for Tendon Subluxation

    OpenAIRE

    Mirmiran, Roya; Squire, Chad; Wassell, Daniel

    2015-01-01

    A low lying peroneus brevis muscle belly is a rare anomaly. There are few published studies that support presence of this anomaly as an etiology for peroneal tendon tear. However, the association between a low lying peroneus muscle belly (LLMB) and tendon subluxation is not well explored. In this retrospective study, the magnetic resonance imaging (MRI) and intraoperative findings of 50 consecutive patients undergoing a primary peroneal tendon surgery, in a five year period, were assessed. Th...

  11. Rotator cuff repair with a tendon-fibrocartilage-bone composite bridging patch.

    Science.gov (United States)

    Ji, Xiaoxi; Chen, Qingshan; Thoreson, Andrew R; Qu, Jin; An, Kai-Nan; Amadio, Peter C; Steinmann, Scott P; Zhao, Chunfeng

    2015-11-01

    To compare the mechanical performance of a rotator cuff repaired with a novel tendon-fibrocartilage-bone composite bridging patch vs the traditional Mason-Allen repair in an in vitro canine model. Twenty shoulders and 10 bridging patches from patellar tendon were harvested. The patches were trimmed and sliced into 2 layers. An infraspinatus tendon tear was created in each shoulder. Modified Mason-Allen sutures were used to repair the infraspinatus tendon to the greater tuberosity, with or without the bridging patch (bridging patch group and controls, respectively). Shoulders were loaded to failure under displacement control at a rate of 0.5mm/s. The ultimate tensile load was significantly higher in the bridging patch group than control (mean [SD], 365.46 [36.45] vs 272.79 [48.88] N; Pfibrocartilage-bone composite bridging patch achieved higher ultimate tensile load and stiffness at the patch-greater tuberosity repair site compared with traditional repair in a canine model. This composite tissue transforms the traditional tendon-to-bone healing interface (with dissimilar tissues) into a pair of bone-to-bone and tendon-to-tendon interfaces, which may improve healing quality and reduce retear rate. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Substitution of porcine small intestinal submucosa for rabbit Achilles tendon, an experimental study.

    Science.gov (United States)

    Gu, Yan; Dai, Kerong

    2002-09-25

    To study the effect of substitution of porcine small intestinal submucosa (SIS) for rabbit Achilles tendon. Porcine SIS was taken out and processed. Part of Achilles tendons of 20 rabbits' right legs were removed and substituted by porcine SIS and the Achilles tendon of the left legs were used as controls. One, four, eight, twelve, and sixteen weeks after the operation 4 rabbits were killed and their right Achilles tendons were taken out to be examined histologically and their maximum load was tested. One week after the operation, the porcine SIS was already fused with the remaining part of rabbit Achilles tendon. Sixteen weeks after all the Achilles tendons looked like normal one. The maximum load of experimental Achilles tendon was 48 N +/- 9 N one week after the operation, and increased gradually. In the 16th week after the operation, the maximum load was 178 N +/- 6 N for the experimental Achilles tendon and 174 N +/- 10 N for the control tendon. The differences of maximum load between different weeks after operation, except that between one week and 4 weeks after, were statistically significant (P Achilles tendon is effective, thus proving the feasibility of in vivo tissue engineering technology.

  13. Engaging Stem Cells for Customized Tendon Regeneration

    Directory of Open Access Journals (Sweden)

    Hatim Thaker

    2012-01-01

    Full Text Available The need for a consistent therapeutic approach to tendon injury repair is long overdue. Patients with tendon microtears or full ruptures are eligible for a wide range of invasive and non invasive interventions, often subjectively decided by the physician. Surgery produces the best outcomes, and while studies have been conducted to optimize graft constructs and to track outcomes, the data from these studies have been inconclusive on the whole. What has been established is a clear understanding of healthy tendon architecture and the inherent process of healing. With this knowledge, tissue regeneration efforts have achieved immense progress in scaffold design, cell line selection, and, more recently, the appropriate use of cytokines and growth factors. This paper evaluates the plasticity of bone-marrow-derived stem cells and the elasticity of recently developed biomaterials towards tendon regeneration efforts. Mesenchymal stem cells (MSCs, hematopoietic progenitor cells, and poly(1,8-octanediol co-citrate scaffolds (POC are discussed in the context of established grafting strategies. With POC scaffolds to cradle the growth of MSCs and hematopoietic progenitor cells, developing a fibroelastic network guided by cytokines and growth factors may contribute towards consistent graft constructs, enhanced functionality, and better patient outcomes.

  14. Tissue-engineering strategies for the tendon/ligament-to-bone insertion.

    Science.gov (United States)

    Smith, Lester; Xia, Younan; Galatz, Leesa M; Genin, Guy M; Thomopoulos, Stavros

    2012-01-01

    Injuries to connective tissues are painful and disabling and result in costly medical expenses. These injuries often require reattachment of an unmineralized connective tissue to bone. The uninjured tendon/ligament-to-bone insertion (enthesis) is a functionally graded material that exhibits a gradual transition from soft tissue (i.e., tendon or ligament) to hard tissue (i.e., mineralized bone) through a fibrocartilaginous transition region. This transition is believed to facilitate force transmission between the two dissimilar tissues by ameliorating potentially damaging interfacial stress concentrations. The transition region is impaired or lost upon tendon/ligament injury and is not regenerated following surgical repair or natural healing, exposing the tissue to risk of reinjury. The need to regenerate a robust tendon-to-bone insertion has led a number of tissue engineering repair strategies. This review treats the tendon-to-bone insertion site as a tissue structure whose primary role is mechanical and discusses current and emerging strategies for engineering the tendon/ligament-to-bone insertion in this context. The focus lies on strategies for producing mechanical structures that can guide and subsequently sustain a graded tissue structure and the associated cell populations.

  15. Applied Joint-Space Torque and Stiffness Control of Tendon-Driven Fingers

    Science.gov (United States)

    Abdallah, Muhammad E.; Platt, Robert, Jr.; Wampler, Charles W.; Hargrave, Brian

    2010-01-01

    Existing tendon-driven fingers have applied force control through independent tension controllers on each tendon, i.e. in the tendon-space. The coupled kinematics of the tendons, however, cause such controllers to exhibit a transient coupling in their response. This problem can be resolved by alternatively framing the controllers in the joint-space of the manipulator. This work presents a joint-space torque control law that demonstrates both a decoupled and significantly faster response than an equivalent tendon-space formulation. The law also demonstrates greater speed and robustness than comparable PI controllers. In addition, a tension distribution algorithm is presented here to allocate forces from the joints to the tendons. It allocates the tensions so that they satisfy both an upper and lower bound, and it does so without requiring linear programming or open-ended iterations. The control law and tension distribution algorithm are implemented on the robotic hand of Robonaut-2.

  16. GH receptor blocker administration and muscle-tendon collagen synthesis in humans

    DEFF Research Database (Denmark)

    Nielsen, Rie Harboe; Doessing, Simon; Goto, Kazushige

    2011-01-01

    Collagen is the predominant structural protein in tendons and ligaments, and can be controlled by hormonal changes. In animals, injections of insulin-like growth factor I (IGF-I) has been shown to increase collagen synthesis in tendons and ligaments and to improve structural tissue healing......, but the effect of local IGF-I administration on tendon collagen synthesis in human has not been studied. The purpose of this study was to study whether local injections of IGF-I would have a stimulating effect on tendon collagen synthesis. Twelve healthy nonsmoking men [age 62 ± 1 years (mean ± SEM), BMI 27 ± 1......] participated. Two injections of either human recombinant IGF-I (0.1 mL Increlex©) or saline (control) into each patellar tendon were performed 24-h apart, respectively. Tendon collagen fractional synthesis rate (FSR) was measured by stable isotope technique in the hours after the second injection...

  17. Pentadecapeptide BPC 157 Enhances the Growth Hormone Receptor Expression in Tendon Fibroblasts

    Directory of Open Access Journals (Sweden)

    Chung-Hsun Chang

    2014-11-01

    Full Text Available BPC 157, a pentadecapeptide derived from human gastric juice, has been demonstrated to promote the healing of different tissues, including skin, muscle, bone, ligament and tendon in many animal studies. However, the underlying mechanism has not been fully clarified. The present study aimed to explore the effect of BPC 157 on tendon fibroblasts isolated from Achilles tendon of male Sprague-Dawley rat. From the result of cDNA microarray analysis, growth hormone receptor was revealed as one of the most abundantly up-regulated genes in tendon fibroblasts by BPC 157. BPC 157 dose- and time-dependently increased the expression of growth hormone receptor in tendon fibroblasts at both the mRNA and protein levels as measured by RT/real-time PCR and Western blot, respectively. The addition of growth hormone to BPC 157-treated tendon fibroblasts dose- and time-dependently increased the cell proliferation as determined by MTT assay and PCNA expression by RT/real-time PCR. Janus kinase 2, the downstream signal pathway of growth hormone receptor, was activated time-dependently by stimulating the BPC 157-treated tendon fibroblasts with growth hormone. In conclusion, the BPC 157-induced increase of growth hormone receptor in tendon fibroblasts may potentiate the proliferation-promoting effect of growth hormone and contribute to the healing of tendon.

  18. Manipulation of Foot Strike and Footwear Increases Achilles Tendon Loading During Running.

    Science.gov (United States)

    Rice, Hannah; Patel, Mubarak

    2017-08-01

    The Achilles tendon is the most common site of tendon overuse injury in humans. Running with a forefoot strike pattern and in minimal shoes is a topic of recent interest, yet evidence is currently limited regarding the combined influence of foot strike and footwear on Achilles tendon loading. To investigate the influence of both foot strike and footwear on Achilles tendon loading in habitual rearfoot strike runners. Controlled laboratory study. Synchronized kinematic and force data were collected from 22 habitual rearfoot strikers (11 male), who habitually ran in nonminimal running shoes, during overground running at 3.6 m·s -1 . Participants ran in 3 different footwear conditions (standard running shoe, minimal running shoe, and barefoot) with both a rearfoot strike (RFS) and an imposed forefoot strike (FFS) in each footwear condition. Achilles tendon loading was estimated by use of inverse dynamics, where the Achilles tendon moment arm was determined with a regression equation. A 2-way, repeated-measures analysis of variance was used to compare conditions. Achilles tendon impulse was greater when subjects ran with an FFS rather than an RFS in minimal shoes. Achilles tendon loading rates were higher when subjects ran either in minimal shoes or barefoot than in standard shoes, regardless of foot strike. In runners who habitually rearfoot strike in standard running shoes, running in minimal shoes or barefoot increased the rate of tendon loading, and running with a forefoot strike in minimal shoes increased the magnitude of tendon loading. Transitioning to these running conditions may increase the risk of tendinopathy.

  19. Tissue-Engineered Tendon for Enthesis Regeneration in a Rat Rotator Cuff Model

    Directory of Open Access Journals (Sweden)

    Michael J. Smietana

    2017-06-01

    Full Text Available Healing of rotator cuff (RC injuries with current suture or augmented scaffold techniques fails to regenerate the enthesis and instead forms a weaker fibrovascular scar that is prone to subsequent failure. Regeneration of the enthesis is the key to improving clinical outcomes for RC injuries. We hypothesized that the utilization of our tissue-engineered tendon to repair either an acute or a chronic full-thickness supraspinatus tear would regenerate a functional enthesis and return the biomechanics of the tendon back to that found in native tissue. Engineered tendons were fabricated from bone marrow-derived mesenchymal stem cells utilizing our well-described fabrication technology. Forty-three rats underwent unilateral detachment of the supraspinatus tendon followed by acute (immediate or chronic (4 weeks retracted repair by using either our engineered tendon or a trans-osseous suture technique. Animals were sacrificed at 8 weeks. Biomechanical and histological analyses of the regenerated enthesis and tendon were performed. Statistical analysis was performed by using a one-way analysis of variance with significance set at p < 0.05. Acute repairs using engineered tendon had improved enthesis structure and lower biomechanical failures compared with suture repairs. Chronic repairs with engineered tendon had a more native-like enthesis with increased fibrocartilage formation, reduced scar formation, and lower biomechanical failure compared with suture repair. Thus, the utilization of our tissue-engineered tendon showed improve enthesis regeneration and improved function in chronic RC repairs compared with suture repair. Clinical Significance: Our engineered tendon construct shows promise as a clinically relevant method for repair of RC injuries.

  20. Study of Achilles Tendon Reflex in Normal Korean and Various Thyroid Diseases

    International Nuclear Information System (INIS)

    Kang, Jin Yung; Kim, Kwang Won; Yae, Sung Bo; Lee, Hong Kyu; Koh, Chang Soon

    1975-01-01

    In an attempt to establish the diagnostic value of Achilles tendon reflex and to determine the normal value of Achilles tendon reflex time in normal Korean, the author measured the Achilles tendon reflex time by photomotograph. This study was carried out in 272 cases with various thyroid diseases and 340 normal Korean. 1) The Achilles tendon reflex time in normal Korean was like this, between 11 years old and 20 years old; male (62 cases); 250±27 msec, female (36 cases); 266±27 msec, between 21 years old and 30 years old; male (38 cases); 271±27 msec, female (21 cases); 284±27 msec, between 31 years old and 40 years old; male (26 cases); 275±25 msec, female (29 cases); 291±27 msec, between 41 years old and 50 years old; male (20 cases); 286±35 msec, female (24 cases); 307±42 msec, between 51 years old and 60 years old, male (20 cases); 296±33 msec, female (20 cases); 318±46 msec, over 61 years; male (24 cases) 301±33 msec, female (20 cases); 325±35 msec. The Achilles tendon reflex time was delayed with increasing age and delayed in the female. 2) The Achilles tendon reflex time was markedly shortened to 221±20 msec in untreated hyperthyroidism. 3) The Achilles tendon reflex time was markedly delayed to 435±59 msec in hypothyroidism. 4) The Achilles tendon reflex time was not changed significantly in other thyroid diseases with norms thyroid function. 5) The Achilles tendon reflex time showed good correlationship with ETR, T 3 RU, 131 I thyroid uptake and serum TSH. 6) Reproducibility of Achilles tendon reflex time was good, and no significant difference between left and right was noted. 7) Diagnostic accuracy of Achilles tendon reflex time was 71% in hyperthyroidism and 90% in hypothyroidism. 8) The Achilles tendon reflex time showed useful test to evaluate the clinical course of the hyperthyroidism.

  1. A Biomechanical Analysis of Different Clavicular Tunnel Diameters in Anatomic Acromioclavicular Ligament Reconstruction.

    Science.gov (United States)

    Voss, Andreas; Beitzel, Knut; Alaee, Farhang; Dukas, Alex; Herbst, Elmar; Obopilwe, Elifho; Apostolakos, John; DiVenere, Jessica; Singh, Hardeep; Cote, Mark P; Mazzocca, Augustus D

    2016-08-01

    To evaluate the biomechanical stability of a tendon-to-clavicle bone interface fixation of a graft in revision acromioclavicular reconstruction. Fifteen fresh-frozen cadaveric shoulders were used. All specimens underwent bone density evaluation. For the primary reconstruction, a 5-mm semitendinosus allograft was inserted into a 5-mm bone tunnel at 25 and 45 mm from the lateral end of the clavicle using a 5.5 × 8-mm PEEK (polyether ether ketone) tenodesis screw. Each single graft was fixed in a cryo-clamp and cyclically loaded from 5 to 70 N for 3,000 cycles, followed by load-to-failure testing at a rate of 120 mm/min to simulate the revision case. To simulate tunnel widening, the tunnels of the revision series were over-drilled with an 8-mm drill, and a 5-mm semitendinosus graft with an 8 × 12-mm PEEK tenodesis screw was inserted. Biomechanical testing was then repeated. The bone mineral density analysis showed a significantly higher density at the 45-mm hole compared with the 25-mm hole (P = .001). The ultimate load to failure increased from the 5.5-mm screw to the 8-mm screw at the 45-mm hole position (P = .001). There was no statistically significant difference at the 25-mm hole position (P = .934). No statistical significance for graft elongation comparing the 5.5-mm screw and the 8-mm screw at the 25-mm (P = .156) and 45-mm (P = .334) positions could be found. Comparable biomechanical stability for the tendon-to-bone interface fixation in different clavicular tunnel diameters simulating primary and revision reconstruction was achieved. There is a lack of literature regarding revision acromioclavicular joint reconstruction, but our biomechanical results show comparable stability to primary reconstruction. These data provide support for the use of anatomic acromioclavicular ligament reconstruction in revision cases. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  2. The Influence of External Load on Quadriceps Muscle and Tendon Dynamics during Jumping.

    Science.gov (United States)

    Earp, Jacob E; Newton, Robert U; Cormie, Prue; Blazevich, Anthony J

    2017-11-01

    Tendons possess both viscous (rate-dependent) and elastic (rate-independent) properties that determine tendon function. During high-speed movements external loading increases both the magnitude (FT) and rate (RFDT) of tendon loading. The influence of external loading on muscle and tendon dynamics during maximal vertical jumping was explored. Ten resistance-trained men performed parallel-depth, countermovement vertical jumps with and without additional load (0%, 30%, 60%, and 90% of maximum squat lift strength), while joint kinetics and kinematics, quadriceps tendon length (LT) and patellar tendon FT and RFDT were estimated using integrated ultrasound, motion analysis and force platform data and muscle tendon modelling. Estimated FT and RFDT, but not peak LT, increased with external loading. Temporal comparisons between 0% and 90% loads revealed that FT was greater with 90% loading throughout the majority of the movement (11%-81% and 87%-95% movement duration). However, RFDT was greater with 90% load only during the early movement initiation phase (8%-15% movement duration) but was greater in the 0% load condition later in the eccentric phase (27%-38% movement duration). LT was longer during the early movement (12%-23% movement duration) but shorter in the late eccentric and early concentric phases (48%-55% movement duration) with 90% load. External loading positively influenced peak FT and RFDT but tendon strain appeared unaffected, suggesting no additive effect of external loading on patellar tendon lengthening during human jumping. Temporal analysis revealed that external loading resulted in a large initial RFDT that may have caused dynamic stiffening of the tendon and attenuated tendon strain throughout the movement. These results suggest that external loading influences tendon lengthening in both a load- and movement-dependent manner.

  3. Clinical evaluation of bone- patellar tendon- bone grafts for anterior cruciate ligament injury

    International Nuclear Information System (INIS)

    Nakamura, Yasuhiro

    2011-01-01

    One thousand and thirty-eight cases of Anterior Cruciate Ligament (ACL) rupture were treated between January 2002 and November 2010. Eight hundred sixty-six cases (83.9%) were observed for at least six months. All cases were reconstructed with a bone to tendon to bone (BTB) graft from the patella. Much effort was made to return the patient to a competitive sports activity level within one year. The age at suffering from the initial injury ranged from 9 to 74 years old with a mean of 24.7 years old. There were 493 female (50.7%) and 427 male (49.3%) cases. The injured side was right in 408 cases and left in 458 cases. The mean postoperative observation period was 449.2 days. The number of patients who felt 80% or more certain that they could return to competitive sports activities was 538 (61.9%). From the MRI findings, continuity of the reconstructed graft was observed in 793 cases (98.5%). Arthroscopy after reconstruction was performed in 775 cases (89.5%). The reconstructed ACL was observed to be covered with an adequate synovium in 629 cases (81.2%). The medial meniscus and lateral meniscus showed no changes in 657 cases (84.8%) and 666 cases (85.9%) respectively. Reconstructions performed less than two weeks after injury showed no significant differences in terms of Range Of Motion (ROM), arthroscopic findings, or the number of patients who could return to competitive sports activities. Statistically significantly more patients who underwent their reconstruction at an age over forty experienced a loss motion of five degree in extension or ten degree in flexion and resumed a lower level of sports activities. Patients who underwent the reconstruction could return to exercises for muscle strengthening and ROMs within 2 weeks. Patients over forty years old who underwent their reconstruction could prevent their menisci from fraying, tearing, or undergoing osteoarthritic changes. (author)

  4. Tendinopathy of the long head of the biceps tendon: histopathologic analysis of the extra-articular biceps tendon and tenosynovium.

    Science.gov (United States)

    Streit, Jonathan J; Shishani, Yousef; Rodgers, Mark; Gobezie, Reuben

    2015-01-01

    Bicipital tendinitis is a common cause of anterior shoulder pain, but there is no evidence that acute inflammation of the extra-articular long head of the biceps (LHB) tendon is the root cause of this condition. We evaluated the histologic findings of the extra-articular portion of the LHB tendon and synovial sheath in order to compare those findings to known histologic changes seen in other tendinopathies. Twenty-six consecutive patients (mean age 45.4±13.7 years) underwent an open subpectoral biceps tenodesis for anterior shoulder pain localized to the bicipital groove. Excised tendons were sent for histologic analysis. Specimens were graded using a semiquantitative scoring system to evaluate tenocyte morphology, the presence of ground substance, collagen bundle characteristics, and vascular changes. Chronic inflammation was noted in only two of 26 specimens, and no specimen demonstrated acute inflammation. Tenocyte enlargement and proliferation, characterized by increased roundness and size of the cell and nucleus with proteoglycan matrix expansion and myxoid degenerative changes, was found in all 26 specimens. Abundant ground substance, collagen bundle changes, and increased vascularization were visualized in all samples. Anterior shoulder pain attributed to the biceps tendon does not appear to be due to an inflammatory process in most cases. The histologic findings of the extra-articular portion of the LHB tendon and synovial sheath are similar to the pathologic findings in de Quervain tenosynovitis at the wrist, and may be due to a chronic degenerative process similar to this and other tendinopathies of the body.

  5. Different culture conditions affect the growth of human tendon stem/progenitor cells (TSPCs) within a mixed tendon cells (TCs) population.

    Science.gov (United States)

    Viganò, M; Perucca Orfei, C; Colombini, A; Stanco, D; Randelli, P; Sansone, V; de Girolamo, L

    2017-12-01

    Tendon resident cells (TCs) are a mixed population made of terminally differentiated tenocytes and tendon stem/progenitor cells (TSPCs). Since the enrichment of progenitors proportion could enhance the effectiveness of treatments based on these cell populations, the interest on the effect of culture conditions on the TSPCs is growing. In this study the clonal selection and the culture in presence or absence of basic fibroblast growth factor (bFGF) were used to assess their influences on the stemness properties and phenotype specific features of tendon cells. Cells cultured with the different methods were analyzed in terms of clonogenic and differentiation abilities, stem and tendon specific genes expression and immunophenotype at passage 2 and passage 4. The clonal selection allowed to isolate cells with a higher multi-differentiation potential, but at the same time a lower proliferation rate in comparison to the whole population. Moreover, the clones express a higher amounts of stemness marker OCT4 and tendon specific transcription factor Scleraxis (SCX) mRNA, but a lower level of decorin (DCN). On the other hand, the number of cells obtained by clonal selection was extremely low and most of the clones were unable to reach a high number of passages in cultures. The presence of bFGF influences TCs morphology, enhance their proliferation rate and reduce their clonogenic ability. Interestingly, the expression of CD54, a known mesenchymal stem cell marker, is reduced in presence of bFGF at early passages. Nevertheless, bFGF does not affect the chondrogenic and osteogenic potential of TCs and the expression of tendon specific markers, while it was able to downregulate the OCT4 expression. This study showed that clonal selection enhance progenitors content in TCs populations, but the extremely low number of cells produced with this method could represent an insurmountable obstacle to its application in clinical approaches. We observed that the addition of bFGF to the

  6. Changes in tendon spatial frequency parameters with loading.

    Science.gov (United States)

    Pearson, Stephen J; Engel, Aaron J; Bashford, Gregory R

    2017-05-24

    To examine and compare the loading related changes in micro-morphology of the patellar tendon. Fifteen healthy young males (age 19±3yrs, body mass 83±5kg) were utilised in a within subjects matched pairs design. B mode ultrasound images were taken in the sagittal plane of the patellar tendon at rest with the knee at 90° flexion. Repeat images were taken whilst the subjects were carrying out maximal voluntary isometric contractions. Spatial frequency parameters related to the tendon morphology were determined within regions of interest (ROI) from the B mode images at rest and during isometric contractions. A number of spatial parameters were observed to be significantly different between resting and contracted images (Peak spatial frequency radius (PSFR), axis ratio, spatial Q-factor, PSFR amplitude ratio, and the sum). These spatial frequency parameters were indicative of acute alterations in the tendon micro-morphology with loading. Acute loading modifies the micro-morphology of the tendon, as observed via spatial frequency analysis. Further research is warranted to explore its utility with regard to different loading induced micro-morphological alterations, as these could give valuable insight not only to aid strengthening of this tissue but also optimization of recovery from injury and treatment of conditions such as tendinopathies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Stretching Your Energetic Budget: How Tendon Compliance Affects the Metabolic Cost of Running.

    Directory of Open Access Journals (Sweden)

    Thomas K Uchida

    Full Text Available Muscles attach to bones via tendons that stretch and recoil, affecting muscle force generation and metabolic energy consumption. In this study, we investigated the effect of tendon compliance on the metabolic cost of running using a full-body musculoskeletal model with a detailed model of muscle energetics. We performed muscle-driven simulations of running at 2-5 m/s with tendon force-strain curves that produced between 1 and 10% strain when the muscles were developing maximum isometric force. We computed the average metabolic power consumed by each muscle when running at each speed and with each tendon compliance. Average whole-body metabolic power consumption increased as running speed increased, regardless of tendon compliance, and was lowest at each speed when tendon strain reached 2-3% as muscles were developing maximum isometric force. When running at 2 m/s, the soleus muscle consumed less metabolic power at high tendon compliance because the strain of the tendon allowed the muscle fibers to operate nearly isometrically during stance. In contrast, the medial and lateral gastrocnemii consumed less metabolic power at low tendon compliance because less compliant tendons allowed the muscle fibers to operate closer to their optimal lengths during stance. The software and simulations used in this study are freely available at simtk.org and enable examination of muscle energetics with unprecedented detail.

  8. Magnetic resonance imaging appearance of partial latissimus dorsi muscle tendon tear

    International Nuclear Information System (INIS)

    Le, Huy B.Q.; Lee, Steven T.; Lane, Michael D.; Munk, Peter L.; Malfair, David; Blachut, Piotr A.

    2009-01-01

    There is still a paucity of information about the clinical presentation, treatment and imaging findings of latissimus muscle tears. Only one study has specifically described the magnetic resonance imaging (MRI) features of latissimus tendon tears. We describe a case of a high-grade tear in the latissimus muscle tendon in an active water skier with no significant prior medical history. MRI demonstrated at least a 50% tear of the latissimus tendon, manifesting as increased signal intensity on T2-weighted sequences and surrounding edema, as well as a diminutive tendon at the humeral insertion. (orig.)

  9. Analysis of achilles tendon vascularity with second-generation contrast-enhanced ultrasound.

    Science.gov (United States)

    Genovese, Eugenio; Ronga, Mario; Recaldini, Chiara; Fontana, Federico; Callegari, Leonardo; Maffulli, Nicola; Fugazzola, Carlo

    2011-01-01

    To compare morphological, power Doppler, and contrast-enhanced ultrasound (CEUS) features of the Achilles tendon between asymptomatic athletes and athletes who had undergone surgical repair of a previous rupture. Twenty-four athletes were divided in two groups (A and B). Group A included 14 patients with a median age of 32 years (range 27 to 47 years) who had undergone surgical repair for unilateral Achilles tendon rupture. Group B (control group) included 10 subjects with a median age of 34 years (range 27 to 40 years) with no previous or present history of tendinopathy. All patients were evaluated with ultrasound, power Doppler, and CEUS with second-generation contrast agent. We studied the uninjured Achilles tendon in athletes of group A and either the left or the right Achilles tendon of the athletes in group B. CEUS showed a significantly greater ability to detect a greater number of vascular spots within the uninjured tendon of group A compared to group B (power Doppler ultrasound in the uninjured contralateral Achilles tendon. CEUS is useful to evaluate vascularity not detected by other imaging techniques. Vascularity in the uninjured tendon seems to be increased in patients who had a previous rupture. Copyright © 2011 Wiley Periodicals, Inc.

  10. Test of measuring frictional loss of tendons for PCCVs and others

    International Nuclear Information System (INIS)

    Igaki, Tsutomu; Kondo, Shigeru; Tadano, Naonori.

    1981-01-01

    Kansai Electric Power Co., Inc., has carried out the experimental research on large capacity tendons in order to introduce the prestressing structurally required for PCCVs since 1978. This experimental research is concerned with large circular cylinder structures using the large capacity tendons of unbonded type, and aimed at clarifying the problems concerning their design and construction. Through the experiment of prestressing the partial models of full size with the tendons of 1000 t class, the basic experiment on materials, the investigations of concrete placing and tendon arrangement, and the measurement before and after prestressing were carried out, and the studies on the loss of tension the soundness of anchoring part, and the capability of construction were made. The specimens were a rectangular block with 14 tendons, a circular cylinder of two-buttress type with 3 tendons, a U-type specimen simulating the vertical section and a C-type specimen simulating the horizontal section. It seems advantageous to decrease the number of buttresses in view of workability and economy when large capacity tendons are used, and it was confirmed that two-buttress construction did not cause problem at all. It was judged that the anchoring part was sufficiently safe. Concerning the friction during tensioning, the effectiveness rate was estimated. (Kako, I.)

  11. Ultrasound demonstration of distal biceps tendon bifurcation: normal and abnormal findings

    International Nuclear Information System (INIS)

    Tagliafico, Alberto; Capaccio, Enrico; Derchi, Lorenzo E.; Martinoli, Carlo; Michaud, Johan

    2010-01-01

    We demonstrate the US appearance of the distal biceps tendon bifurcation in normal cadavers and volunteers and in those affected by various disease processes. Three cadaveric specimens, 30 normal volunteers, and 75 patients were evaluated by means of US. Correlative MR imaging was obtained in normal volunteers and patients. In all cases US demonstrated the distal biceps tendon shaped by two separate tendons belonging to the short and long head of the biceps brachii muscle. Four patients had a complete rupture of the distal insertion of the biceps with retraction of the muscle belly. Four patients had partial tear of the distal biceps tendon with different US appearance. In two patients the partial tear involved the short head of the biceps brachii tendon, while in the other two patients, the long head was involved. Correlative MR imaging is also presented both in normal volunteers and patients. US changed the therapeutic management in the patients with partial tears involving the LH of the biceps. This is the first report in which ultrasound considers the distal biceps tendon bifurcation in detail. Isolated tears of one of these components can be identified by US. Knowledge of the distal biceps tendon bifurcation ultrasonographic anatomy and pathology has important diagnostic and therapeutic implications. (orig.)

  12. Fascicles and the interfascicular matrix show decreased fatigue life with ageing in energy storing tendons.

    Science.gov (United States)

    Thorpe, Chavaunne T; Riley, Graham P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2017-07-01

    Tendon is composed of rope-like fascicles bound together by interfascicular matrix (IFM). The IFM is critical for the function of energy storing tendons, facilitating sliding between fascicles to allow these tendons to cyclically stretch and recoil. This capacity is required to a lesser degree in positional tendons. We have previously demonstrated that both fascicles and IFM in energy storing tendons have superior fatigue resistance compared with positional tendons, but the effect of ageing on the fatigue properties of these different tendon subunits has not been determined. Energy storing tendons become more injury-prone with ageing, indicating reduced fatigue resistance, hence we tested the hypothesis that the decline in fatigue life with ageing in energy storing tendons would be more pronounced in the IFM than in fascicles. We further hypothesised that tendon subunit fatigue resistance would not alter with ageing in positional tendons. Fascicles and IFM from young and old energy storing and positional tendons were subjected to cyclic fatigue testing until failure, and mechanical properties were calculated. The results show that both IFM and fascicles from the SDFT exhibit a similar magnitude of reduced fatigue life with ageing. By contrast, the fatigue life of positional tendon subunits was unaffected by ageing. The age-related decline in fatigue life of tendon subunits in energy storing tendons is likely to contribute to the increased risk of injury in aged tendons. Full understanding of the mechanisms resulting in this reduced fatigue life will aid in the development of treatments and interventions to prevent age-related tendinopathy. Understanding the effect of ageing on tendon-structure function relationships is crucial for the development of effective preventative measures and treatments for age-related tendon injury. In this study, we demonstrate for the first time that the fatigue resistance of the interfascicular matrix decreases with ageing in energy

  13. An investigation of tendon sheathing filler migration into concrete

    International Nuclear Information System (INIS)

    Naus, D.J.; Oland, C.B.

    1998-03-01

    During some of the inspections at nuclear power plants with prestressed concrete containments, it was observed that the containments has experienced leakage of the tendon sheathing filler (i.e., streaks). The objective of this activity was to provide an indication of the extent of tendon sheathing filler leakage into the concrete and its affects on concrete properties. Literature was reviewed and concrete core samples were obtained from the Trojan Nuclear Plant and tested. The literature primarily addressed effects of crude or lubricating oils that are known to cause concrete damage. However, these materials have significantly different characteristics relative to the materials used as tendon sheathing fillers. Examination and testing of the concrete cores indicated that the appearance of tendon sheathing filler on the concrete surface was due to leakage from the conduits and its subsequent migration through cracks that were present. Migration of the tendon sheathing filler was confined to the cracks and there was no perceptible movement into the concrete. Results of compressive strength testing indicated that the concrete quality was consistent in the containment and that the strength had increased over 40% in 25.4 years relative to the average compressive strength at 28-days age

  14. Eccentric Training for Tendon Healing After Acute Lesion: A Rat Model.

    Science.gov (United States)

    Kaux, Jean-François; Libertiaux, Vincent; Leprince, Pierre; Fillet, Marianne; Denoel, Vincent; Wyss, Clémence; Lecut, Christelle; Gothot, André; Le Goff, Caroline; Croisier, Jean-Louis; Crielaard, Jean-Michel; Drion, Pierre

    2017-05-01

    The tendon is a dynamic entity that remodels permanently. Platelet-rich plasma (PRP) injection has been shown to have a beneficial effect on tendon healing after lesion in rats. Furthermore, eccentric exercise seems to improve the mechanical quality of the tendon. A combination of PRP injection and eccentric training might be more effective than either treatment alone. Controlled laboratory study. Adult male rats were anesthetized, an incision was performed in the middle of their left patellar tendon and an injection of physiological fluid (PF) or homologous PRP was randomly made at the lesion level. The rats were then divided into 2 groups: the eccentric group, undergoing eccentric training 3 times a week, and the untrained group, without any training. Thus, 4 groups were compared. After 5 weeks, the tendons were removed and their ultimate tensile strength and energy were measured. Tendons were frozen for proteomic analyses when all biomechanical tests were completed. Statistical analysis was performed with linear mixed effect models. No significant difference was found between the treatments using PF injection or PRP injection alone. However, the value of the ultimate tensile force at rupture was increased by 4.5 N (108% of control, P = .006) when eccentric training was performed. An intragroup analysis revealed that eccentric training significantly improved the ultimate force values for the PRP group. Proteomic analysis revealed that eccentric training led to an increase in abundance of several cytoskeletal proteins in the PF group, while a decrease in abundance of enzymes of the glycolytic pathway occurred in the PRP-treated groups, indicating that this treatment might redirect the exercise-driven metabolic plasticity of the tendon. Eccentric training altered the metabolic plasticity of tendon and led to an improvement of injured tendon resistance regardless of the treatment injected (PF or PRP). This study demonstrates the necessity of eccentric rehabilitation

  15. The occurrence of osteoarthritis at a minimum of ten years after reconstruction of the anterior cruciate ligament

    Directory of Open Access Journals (Sweden)

    Patt Thomas W

    2008-06-01

    Full Text Available Abstract Objective The objective of this study was to evaluate the incidence of radiographic osteoarthritis in the operated knee in comparison with the contralateral knee ten years after a bone-tendon bone patellar autograft ACL-reconstruction and to evaluate to which level patients regain activity ten years after reconstruction. Methods Fifty-three patients with ACL instability were operated arthroscopically using the central third of the patellar tendon as a bone-tendon-bone autograft. At a minimum of 10 year follow up 28/44 patients matched the inclusion criteria and could be reached for follow-up. Evaluation included a patient satisfaction evaluation using a Visual Analog Scale, physical examination (International Knee Documentation Committee score, Tegner score, Lysholm score, KT-1000 stabilometry and a radiological evaluation (Kellgren and Fairbanks classification. Results The patients' satisfaction, at a mean of 10,3 year follow-up, measured with a VAS score (0–10 was high with a mean of 8.5 (range 4 to 10. The KT 1000 arthrometer laxity measurements revealed in 55% of the patients an A rating (1–2 mm, in 29% a B rating (3–5 mm and in 16% a C rating (6–10 mm. According to the Tegner score 54% of the patients were able to perform at the same activity level as pre-operatively. The mean pre-operative Tegner score was 6.8 and the mean post-operative Tegner score was 6.0 at final follow up. The Lysholm score showed satisfactory results with a mean of 91 points (range 56 to 100. According to the Kellgren and Fairbank classifications, there is a significant difference (p Conclusion The patellar BTB ACL reconstruction does not prevent the occurrence of radiological OA after 10 years but does help the patient to regain the pre-operative level of activity.

  16. TMJ ankylosis: Management with reconstruction and interpositional ...

    African Journals Online (AJOL)

    Temporomandibular joint (TMJ) ankylosis is a very desolating structural condition that involves fusion of the 1 mandibular condyle to the base of the skull. It causes difficulty in mastication and breathing.Trauma and Infections are usually responsible.If trauma occurs in young age,it leads to disturbance in growth & facial ...

  17. Association between distal ulnar morphology and extensor carpi ulnaris tendon pathology

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Kattapuram, Susan V.; Torriani, Martin [General Hospital and Harvard Medical School, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Massachusetts, Boston, MA (United States)

    2014-06-15

    The purpose of this study was to evaluate the association between distal ulnar morphology and extensor carpi ulnaris (ECU) tendon pathology. We retrospectively reviewed 71 adult wrist MRI studies with ECU tendon pathology (tenosynovitis, tendinopathy, or tear), and/or ECU subluxation. Subjects did not have a history of trauma, surgery, infection, or inflammatory arthritis. MRI studies from 46 subjects without ECU tendon pathology or subluxation were used as controls. The following morphological parameters of the distal ulna were measured independently by two readers: ulnar variance relative to radius, ulnar styloid process length, ECU groove depth and length. Subjects and controls were compared using Student's t test. Inter-observer agreement (ICC) was calculated. There was a significant correlation between negative ulnar variance and ECU tendon pathology (reader 1 [R1], P = 0.01; reader 2 [R2], P < 0.0001; R1 and R2 averaged data, P < 0.0001) and ECU tendon subluxation (P = 0.001; P = 0.0001; P < 0.0001). In subjects with ECU tendon subluxation there was also a trend toward a shorter length (P = 0.3; P <0.0001; P = 0.001) and a shallower ECU groove (P = 0.01; P = 0.03; P = 0.01; R1 and R2 averaged data with Bonferroni correction, P = 0.08). ECU groove depth (P = 0.6; P = 0.8; P = 0.9) and groove length (P = 0.1; P = 0.4; P = 0.7) showed no significant correlation with ECU tendon pathology, and length of the ulnar styloid process showed no significant correlation with ECU tendon pathology (P = 0.2; P = 0.3; P = 0.2) or subluxation (P = 0.4; P = 0.5; P = 0.5). Inter-observer agreement (ICC) was >0.64 for all parameters. Distal ulnar morphology may be associated with ECU tendon abnormalities. (orig.)

  18. Suture anchor tenodesis in repair of distal Achilles tendon injuries.

    Science.gov (United States)

    Kiliçoğlu, Onder; Türker, Mehmet; Yildız, Fatih; Akalan, Ekin; Temelli, Yener

    2014-01-01

    Distal Achilles tendon avulsions are in the form of either bony and nonbony avulsion of Achilles tendon from its calcaneal insertion. Four patients with distal Achilles tendon avulsions or ruptures which were treated with tendon to bone repair using suture anchors are presented here. Operated leg was immobilized in above-knee cast for 4 weeks while the patient walked non-weight-bearing. Then, cast was changed to below knee, and full weight-bearing was allowed. Patients underwent gait analysis minimum at first postoperative year. Mean American Orthopedics Foot Ankle Society ankle/hindfoot score of patients at last visit was 88.75 (range 85-100), and Achilles tendon total rupture score was 77.75 (range 58-87). Mean passive dorsiflexion of injured ankles (14° ± 5°) was lower than uninjured ankles (23° ± 9°). All the kinematic parameters of gait analysis were comparable to the uninjured side. Maximum plantar flexion power of injured ankle was 1.40 W/kg, and this was significantly lower than the contralateral side value 2.38 W/kg; (P = 0.0143). There were no visually altered gait or problems in daily life. Suture anchor tenodesis technique of distal Achilles tendon avulsions was successful in achieving durable osteotendinous repairs.

  19. Long bicipital tendon of the shoulder: normal anatomy and pathologic findings on MR imaging.

    Science.gov (United States)

    Erickson, S J; Fitzgerald, S W; Quinn, S F; Carrera, G F; Black, K P; Lawson, T L

    1992-05-01

    The tendon of the long head of the biceps muscle (long bicipital tendon) has a complex course from its muscle belly to its insertion onto the supraglenoid tubercle/glenoid labrum. It is stabilized by numerous tendinous and ligamentous structures and is, in turn, partly responsible for maintenance of normal glenohumeral function. In this report we describe the anatomy of this tendon, correlating high-resolution MR images with cryomicrotome sections. We illustrate typical MR findings in pathologic conditions affecting the long bicipital tendon sheath, the substance of the tendon, and finally the tendon position.

  20. Mechanical Coupling between Muscle-Tendon Units Reduces Peak Stresses

    NARCIS (Netherlands)

    Maas, Huub; Finni, Taija

    2018-01-01

    The presence of mechanical linkages between synergistic muscles and their common tendons may distribute forces among the involved structures. We review studies, using humans and other animals, examining muscle and tendon interactions and discuss the hypothesis that connections between muscle bellies

  1. Radiographic Features of Acute Patellar Tendon Rupture.

    Science.gov (United States)

    Fazal, Muhammad Ali; Moonot, Pradeep; Haddad, Fares

    2015-11-01

    The purpose of our study was to assess soft tissue features of acute patellar tendon rupture on lateral knee radiograph that would facilitate early diagnosis. The participants were divided into two groups of 35 patients each. There were 28 men and seven women with a mean age of 46 years in the control group and 26 men and nine women with a mean age of 47 years in the rupture group. The lateral knee radiograph of each patient was evaluated for Insall-Salvati ratio for patella alta, increased density of the infrapatellar fat pad, appearance of the soft tissue margin of the patellar tendon and bony avulsions. In the rupture group there were three consistent soft tissue radiographic features in addition to patellar alta. These were increased density of infrapatellar fat pad; loss of sharp, well-defined linear margins of the patellar tendon and angulated wavy margin of the patellar tendon while in the control group these features were not observed. The soft tissue radiographic features described in the rupture group are consistent and reliable. When coupled with careful clinical assessment, these will aid in early diagnosis and further imaging will be seldom required. © 2015 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  2. Achillodynia. Radiological imaging of acute and chronic overuse injuries of the Achilles tendon

    International Nuclear Information System (INIS)

    Syha, R.; Springer, F.; Grosse, U.; Tuebingen Univ.; Ketelsen, D.; Kramer, U.; Horger, M.; Ipach, I.; Schick, F.

    2013-01-01

    In the past decades the incidence of acute and chronic disorders of the Achilles tendon associated with sport-induced overuse has steadily increased. Besides acute complete or partial ruptures, achillodynia (Achilles tendon pain syndrome), which is often associated with tendon degeneration, represents the most challenging entity regarding clinical diagnostics and therapy. Therefore, the use of imaging techniques to differentiate tendon disorders and even characterize structure alterations is of growing interest. This review article discusses the potential of different imaging techniques with respect to the diagnosis of acute and chronic tendon disorders. In this context, the most commonly used imaging techniques are magnetic resonance imaging (MRI), B-mode ultrasound, and color-coded Doppler ultrasound (US). These modalities allow the detection of acute tendon ruptures and advanced chronic tendon disorders. However, the main disadvantages are still the low capabilities in the detection of early-stage degeneration and difficulties in the assessment of treatment responses during follow-up examinations. Furthermore, differentiation between chronic partial ruptures and degeneration remains challenging. The automatic contour detection and texture analysis may allow a more objective and quantitative interpretation, which might be helpful in the monitoring of tendon diseases during follow-up examinations. Other techniques to quantify tendon-specific MR properties, e.g. based on ultrashort echo time (UTE) sequences, also seem to have great potential with respect to the precise detection of degenerative tendon disorders and their differentiation at a very early stage. (orig.)

  3. Rehabilitation of tendon problems in patients with diabetes mellitus

    NARCIS (Netherlands)

    Rees, Jonathan; Gaida, Jamie E.; Silbernagel, Karin Grävare; Zwerver, Johannes; Anthony, Joseph S.; Scott, Alex; Ackermann, PW; Hart, DA

    2016-01-01

    Exercise is crucial in the management of diabetes mellitus and its associated complications. However, individuals with diabetes have a heightened risk of musculoskeletal problems, including tendon pathologies. Diabetes has a significant impact on the function of tendons due to the accumulation of

  4. Congenital cheek teratoma with temporo-mandibular joint ankylosis managed with ultra-thin silicone sheet interpositional arthroplasty.

    Science.gov (United States)

    Bhatnagar, Ankur; Verma, Vinay Kumar; Purohit, Vishal

    2013-01-01

    Primary cheek teratomas are rare with joint ankylosis (TMJA). The fundamental aim in the treatment of TMJA is the successful surgical resection of ankylotic bone, prevention of recurrence, and aesthetic improvement by ensuring functional occlusion. Early treatment is necessary to promote proper growth and function of mandible and to facilitate the positive psychological development of child. Inter-positional arthroplasty with ultra-thin silicone sheet was performed. Advantages include short operative time, less foreign material in the joint space leading to negligible foreign body reactions and least chances of implant extrusion. Instead of excising a large bony segment, a thin silicone sheet was interposed and then sutured ensuring preservation of mandibular height. Aggressive post-operative physiotherapy with custom made dynamic jaw exerciser was used to prevent recurrence.

  5. A tricalcium phosphate/polyether ether ketone anchor bionic fixation device for anterior cruciate ligament reconstruction: Safety and efficacy in a beagle model.

    Science.gov (United States)

    Mao, Genwen; Qin, Zili; Li, Zheng; Li, Xiang; Qiu, Yusheng; Bian, Weiguo

    2018-05-02

    The goal of this study was to develop a bionic fixation device based on the use of a tricalcium phosphate/polyether ether ketone anchor and harvesting of the ulnar carpal flexor muscle tendon for application as a ligament graft in a beagle anterior cruciate ligament (ACL) reconstruction model, with the goal of accelerating the ligament graft-to-bone tunnel healing and providing a robust stability through exploration of this new kind of autologous ligament graft. The safety and efficacy of this fixation device were explored 3 and 6 months after surgery in a beagle ACL reconstruction model using biomechanical tests and comprehensive histological observation. The data were compared using a two-tailed Student's t test and a paired t test. A p value <0.05 was defined as statistically significant. All the models were successfully established. This fixation device possessed the excellent mechanical properties for ACL reconstruction. A comprehensive histological observation revealed that a cartilage layer was visible in the transition zone between the tendon and bone interface at both 3 and 6 months postoperation. The trabecular of the new bone was observed six months after surgery and was found to be similar to a direct connection. This fixation technique provided not only a robust primary mechanical fixation but also a bionic fixation for long-term knee joint stability by accelerating the healing of the tendon to the bone tunnel, showing a high potential for use in clinical practice. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2018. © 2018 Wiley Periodicals, Inc.

  6. Region specific patella tendon hypertrophy in humans following resistance training

    DEFF Research Database (Denmark)

    Kongsgaard, M.; Reitelseder, S; Pedersen, T.G.

    2007-01-01

    AIM: To examine if cross-sectional area (CSA) differs along the length of the human patellar tendon (PT), and if there is PT hypertrophy in response to resistance training. METHODS: Twelve healthy young men underwent baseline and post-training assessments. Maximal isometric knee extension strength...... (MVC) was determined unilaterally in both legs. PT CSA was measured at the proximal-, mid- and distal PT level and quadriceps muscle CSA was measured at mid-thigh level using magnetic resonance imaging. Mechanical properties of the patellar tendons were determined using ultrasonography. Subsequently....... CONCLUSIONS: To our knowledge, this study is the first to report tendon hypertrophy following resistance training. Further, the data show that the human PT CSA varies along the length of the tendon....

  7. MR imaging of delamination tears of the rotator cuff tendons

    International Nuclear Information System (INIS)

    Walz, Daniel M.; Chen, Steven; Miller, Theodore T.; Hofman, Josh

    2007-01-01

    The objective was to describe the imaging appearances and location of delamination tears of the rotator cuff tendons on non-contrast conventional MR imaging. This study was reviewed and approved by our Institutional Review Board. The reports of 548 consecutive MR examinations of the shoulder were reviewed, looking for mention or description of delamination tears of the rotator cuff. The images of the identified cases were then reviewed by two radiologists to confirm the findings. Correlation with surgical and arthroscopic information was then performed. Delamination tears were defined as horizontal retraction of either the bursal or articular surface of the tendon, manifest as thickening of the torn retracted edge, and/or interstitial splitting of the tendon, manifest as fluid-like high signal intensity on fat-suppressed T2-weighted oblique coronal images. Fourteen cases of delamination tears were identified in 13 patients. Ten of the cases involved the supraspinatus tendon, all with articular surface involvement. Nine of these supraspinatus cases were isolated tears and one occurred as part of a full thickness tear. All 10 of these supraspinatus cases showed medial retraction of the articular surface of the tendon, with thickening of the retracted edge, and 5 of the 10 had a demonstrable horizontal cleft in the interstitium. Four cases involved the subscapularis tendon, with articular surface disruption in three and pure interstitial delamination in one. Medial subluxation of the tendon of the long head of the biceps was present in all four cases. No delamination tears occurred on the bursal surface. Only three of the 14 shoulders underwent surgical repair with one confirmation of supraspinatus delamination, one confirmation of a subscapularis tear that had become a full thickness tear 10 months after initial imaging and another interstitial subscapularis delamination that was not identified arthroscopically. Delamination tears occur most often in the

  8. MR imaging of delamination tears of the rotator cuff tendons

    Energy Technology Data Exchange (ETDEWEB)

    Walz, Daniel M.; Chen, Steven [North Shore University Hospital, Department of Radiology, Manhasset, NY (United States); Miller, Theodore T. [Hospital for Special Surgery, Department of Radiology and Imaging, New York, NY (United States); Hofman, Josh [Long Island Jewish Medical Center, New Hyde Park, NY (United States)

    2007-05-15

    The objective was to describe the imaging appearances and location of delamination tears of the rotator cuff tendons on non-contrast conventional MR imaging. This study was reviewed and approved by our Institutional Review Board. The reports of 548 consecutive MR examinations of the shoulder were reviewed, looking for mention or description of delamination tears of the rotator cuff. The images of the identified cases were then reviewed by two radiologists to confirm the findings. Correlation with surgical and arthroscopic information was then performed. Delamination tears were defined as horizontal retraction of either the bursal or articular surface of the tendon, manifest as thickening of the torn retracted edge, and/or interstitial splitting of the tendon, manifest as fluid-like high signal intensity on fat-suppressed T2-weighted oblique coronal images. Fourteen cases of delamination tears were identified in 13 patients. Ten of the cases involved the supraspinatus tendon, all with articular surface involvement. Nine of these supraspinatus cases were isolated tears and one occurred as part of a full thickness tear. All 10 of these supraspinatus cases showed medial retraction of the articular surface of the tendon, with thickening of the retracted edge, and 5 of the 10 had a demonstrable horizontal cleft in the interstitium. Four cases involved the subscapularis tendon, with articular surface disruption in three and pure interstitial delamination in one. Medial subluxation of the tendon of the long head of the biceps was present in all four cases. No delamination tears occurred on the bursal surface. Only three of the 14 shoulders underwent surgical repair with one confirmation of supraspinatus delamination, one confirmation of a subscapularis tear that had become a full thickness tear 10 months after initial imaging and another interstitial subscapularis delamination that was not identified arthroscopically. Delamination tears occur most often in the

  9. Repair of Double Head Pectoralis Major Tendon Avulsion into its Native Footprint Using Bi-cortical EndoButtons and Tendon Sliding Technique.

    Science.gov (United States)

    Prabhu, Jagadish; Faqi, Mohammed Khalid; Alkhalifa, Fahad; Tayara, Bader Kamal; Awad, Rashad Khamis

    2017-01-01

    Injuries to the pectoralis major muscle are relatively infrequent. The mechanism of injury is usually an eccentric shortening of the pectoralis major under heavy load, such as when performing a bench press exercise. We report a case that presented to us with a history of sudden pain in the left pectoral region while doing heavy bench press exercise. The patient sustained a type III D pectoralis muscle -tendon avulsion. Surgical repair was done through a bi-cortical tendon sliding technique using two cortical buttons. In this article we describe our modifications to the previously described surgical technique for the pectoralis major tendon repair using the EndoButton and tension - slide technique, aiming to overcome the possible complications.

  10. Prestressed Containments - Prestress losses and the effects of re-tensioning tendons

    International Nuclear Information System (INIS)

    Lundqvist, P.; Edin, M.; Persson, P.; Frisk, A.

    2015-01-01

    In Sweden the design of nuclear reactor containments, the structure which encloses the reactor vessel, is that of a concrete cylinder prestressed both horizontally and vertically. The main purpose of the containment is to prevent any radioactive discharge to the environment in case of e.g. an internal accident mainly through the induced compressive forces from the prestressing system. Since the tendon forces decrease with time due to long-term mechanism in the materials the remaining tendon forces are measured at regular intervals. In this paper the results from these measurements in the Swedish nuclear power plant Forsmark are presented. In addition, the losses in the cylinder walls were calculated using the models in Eurocode 2, which were modified based on the climatic conditions inside the reactor building. The results from the tendon force measurements showed that the prestress losses are low, between 5 % and 10 %, i.e. the margin to the lowest acceptable limit is currently sufficient. The effects of increasing the tendon forces were also investigated. Results from subsequent measurements on tendons where the tendon forces have been increased indicate that the development of the prestress losses may increase significantly when the tendon forces are increased to levels exceeding those of the original tensioning. The calculated prestress losses were in relatively good agreement with the measured losses, generally, the models somewhat overestimated the measured losses. (authors)

  11. Triceps brachii tendon: anatomic-MR imaging study in cadavers with histologic correlation

    International Nuclear Information System (INIS)

    Belentani, Clarissa; Pastore, Daniel; Wangwinyuvirat, Mani; Dirim, Berna; Trudell, Debra J.; Resnick, Donald; Haghighi, Parviz

    2009-01-01

    The purpose of this cadaveric study was to describe the normal MR anatomy of the triceps brachii tendon (TBT) insertion, to correlate the findings with those seen in anatomic sections and histopathologic analysis, and to review triceps tendon injuries. Twelve cadaveric elbows were used according to institution guidelines. T1-weighted spin-echo MR images were acquired in three planes. Findings on MR imaging were correlated with those derived from anatomic and histologic study. On MR images, the TBT had a bipartite appearance as it inserted on olecranon in all specimens. The insertion of the medial head was deeper than that of the long and lateral heads and was mainly muscular at its insertion, with a small amount of the tendon blending with the muscle distally, necessitating histologic analysis to determine if there was tendon blending with the muscle at the site of insertion and if the medial head inserted together with the common tendon or as a single unit. At histopathologic analysis, the three heads of the triceps tendon had a common insertion on the olecranon. The bipartite aspect of the tendon that was identified in the MR images was not seen by histologic study, indicating that there was a union of the medial and common tendons just before they inserted into bone. TBT has a bipartite appearance on MR images and inserts on olecranon as a single unit. (orig.)

  12. Triceps brachii tendon: anatomic-MR imaging study in cadavers with histologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Belentani, Clarissa [University of California, Department of Radiology, San Diego, CA (United States); Pastore, Daniel; Wangwinyuvirat, Mani; Dirim, Berna; Trudell, Debra J.; Resnick, Donald [University of California, Department of Radiology, San Diego, CA (United States); University of California, VA Medical Center, San Diego, CA (United States); Haghighi, Parviz [University of California, VA Medical Center, San Diego, CA (United States); University of California, Department of Histology, San Diego (United States)

    2009-02-15

    The purpose of this cadaveric study was to describe the normal MR anatomy of the triceps brachii tendon (TBT) insertion, to correlate the findings with those seen in anatomic sections and histopathologic analysis, and to review triceps tendon injuries. Twelve cadaveric elbows were used according to institution guidelines. T1-weighted spin-echo MR images were acquired in three planes. Findings on MR imaging were correlated with those derived from anatomic and histologic study. On MR images, the TBT had a bipartite appearance as it inserted on olecranon in all specimens. The insertion of the medial head was deeper than that of the long and lateral heads and was mainly muscular at its insertion, with a small amount of the tendon blending with the muscle distally, necessitating histologic analysis to determine if there was tendon blending with the muscle at the site of insertion and if the medial head inserted together with the common tendon or as a single unit. At histopathologic analysis, the three heads of the triceps tendon had a common insertion on the olecranon. The bipartite aspect of the tendon that was identified in the MR images was not seen by histologic study, indicating that there was a union of the medial and common tendons just before they inserted into bone. TBT has a bipartite appearance on MR images and inserts on olecranon as a single unit. (orig.)

  13. Healing of the Achilles tendon in rabbits--evaluation by magnetic resonance imaging and histopathology.

    Science.gov (United States)

    Tavares, Wilson Campos; de Castro, Ubiratam Brum; Paulino, Eduardo; Vasconcellos, Leonardo de Souza; Madureira, Ana Paula; Magalhães, Maria Angélica Baron; Mendes, Daniel Victor Moreira; Kakehasi, Adriana Maria; Resende, Vivian

    2014-12-12

    Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) could provide valuable findings for tendon regeneration. A non-invasive image method that can effectively evaluate the quality of the scar tissue has not yet been employed. Thirteen New Zealand rabbits were divided into two groups: group 1--non-treated control (n = 4); group 2--surgical intervention (n = 9). The central portion of the Achilles tendon was resected, and after 30 days, DCE-MRI was performed. Contrast enhancement methods were applied using the region of interest (ROI) technique. In the medium third of the Achilles tendon, the intra-substantial signal intensity and the presence of hyper-intense intra-tendon focus points and of signal heterogeneity were evaluated. Antero-posterior and transversal diameters of the tendon were measured. The Achilles tendon was removed and dissected free from other tissues. Sections from the central part of the tendon were stained for histological analysis. The difference between the contrast enhancement curves of the control and surgical groups (p tendon sheath, which presented irregular contours and intense contrast enhancement. On histology, the Achilles tendon presented diffuse widening of the tendon sheath and wedge-shaped areas with scarring tissue rich in disordered collagen fibres. These findings were related to alteration in the intra-substantial signal intensity, with hyper-signal focus points in the DCE-MRI. MRI with perfusion could be a useful technique for evaluating tissue and fibrous scarring in tendons.

  14. Evaluation of the equine digital flexor tendon sheath using diagnostic ultrasound and contrast radiography

    International Nuclear Information System (INIS)

    Redding, W.R.

    1994-01-01

    This study was designed to evaluate the normal anatomy of the digital flexor tendon sheath using contrast radiography and diagnostic ultrasound. Iodinated contrast medium was injected into eight cadaver limbs and the limbs immediately frozen. Lateromedial and dorsopalmar/plantar radiographs were made. These limps were then cut transversely and proximal to distal radiographs of each slab were made. This cross sectional contrast methodology allowed the visualization of the relative size and shape of the superficial and deep digital flexor tendons as well as the potential space taken by effusions of the digital flexor tendon sheath. The second part of the study used twelve live animals with normal digital flexor tendon sheaths. Ultrasonographic measurement of the structures of the digital flexor tendon sheath at each level were compiled. This documented the ability of diagnostic ultrasound to image: 1) the superficial and deep digital flexor tendons, 2) the proximal and distal ring of the manica flexoria, 3) the straight and oblique sesamoidean ligaments, and 4) the mesotendinous attachments to the superficial and deep flexor tendons. Iodinated contrast medium was then injected into the digital flexor tendon sheath and the ultrasonography repeated. These images were compared with those obtained from contrast radiography and prosections of twenty normal limbs. The iodinated contrast medium enhanced sonographic imaging of the structures of the digital tendon sheath, particularly the abaxial borders of the superficial digital flexor tendon branches and the mesotendinous attachments to the superficial and deep digital flexor tendons

  15. Ruptured human Achilles tendon has elevated metabolic activity up to 1 year after repair

    International Nuclear Information System (INIS)

    Eliasson, Pernilla; Couppe, Christian; Magnusson, S.P.; Lonsdale, Markus; Friberg, Lars; Svensson, Rene B.; Kjaer, Michael; Neergaard, Christian

    2016-01-01

    Following Achilles tendon rupture, running is often allowed after 6 months. However, tendon healing is slow and the metabolic status of the tendon at this point is unknown. The purpose of this study was to investigate tendon metabolism (glucose uptake) and vascularization at 3, 6 and 12 months after Achilles tendon rupture as measured using PET and power Doppler ultrasonography (PDUS). The study group comprised 23 patients with surgically repaired Achilles tendon rupture who were investigated at 3 months (n = 7), 6 months (n = 7) and 12 months (n = 9) after surgery. The triceps surae complex was loaded over 20 min of slow treadmill walking while a radioactive tracer ( 18 F-FDG) was administered prior to PET. Vascularization was measured in terms of PDUS flow activity, and patient-reported outcomes were scored using the Achilles tendon rupture score (ATRS) and sports assessment (VISA-A) questionnaire. Relative glucose uptake ( 18 F-FDG) was higher in repaired tendons than in intact tendons at all time-points (6, 3 and 1.6 times higher at 3, 6 and 12 months, respectively; P ≤ 0.001), and was also higher in the tendon core than in the periphery at 3 and 6 months (P ≤ 0.02), but lower at 12 months (P = 0.06). Relative glucose uptake was negatively related to ATRS at 6 months after repair (r = -0.89, P ≤ 0.01). PDUS flow activity was higher in repaired tendons than in intact tendons at 3 and 6 months (P < 0.05 for both), but had normalized by 12 months. These data demonstrate that the healing process as determined by metabolic activity and vascularization continues for 6 months after injury when large loads are typically allowed on the tendon. Indeed, metabolic activity remained elevated for more than 1 year after injury despite normalized vascularization. The robust negative correlation between tendon metabolism and patient-reported outcome suggests that a high metabolic activity 6 months after the injury may be related to a poor clinical healing outcome. (orig.)

  16. The anatomical footprint of the Achilles tendon: a cadaveric study.

    Science.gov (United States)

    Ballal, M S; Walker, C R; Molloy, A P

    2014-10-01

    We dissected 12 fresh-frozen leg specimens to identify the insertional footprint of each fascicle of the Achilles tendon on the calcaneum in relation to their corresponding muscles. A further ten embalmed specimens were examined to confirm an observation on the retrocalcaneal bursa. The superficial part of the insertion of the Achilles tendon is represented by fascicles from the medial head of the gastrocnemius muscle, which is inserted over the entire width of the inferior facet of the calcaneal tuberosity. In three specimens this insertion was in continuity with the plantar fascia in the form of periosteum. The deep part of the insertion of the Achilles tendon is made of fascicles from the soleus tendon, which insert on the medial aspect of the middle facet of the calcaneal tuberosity, while the fascicles of the lateral head of the gastrocnemius tendon insert on the lateral aspect of the middle facet of the calcaneal tuberosity. A bicameral retrocalcaneal bursa was present in 15 of the 22 examined specimens. This new observation and description of the insertional footprint of the Achilles tendon and the retrocalcaneal bursa may allow a better understanding of the function of each muscular part of the gastrosoleus complex. This may have clinical relevance in the treatment of Achilles tendinopathies. ©2014 The British Editorial Society of Bone & Joint Surgery.

  17. Faster Movement Speed Results in Greater Tendon Strain during the Loaded Squat Exercise

    Science.gov (United States)

    Earp, Jacob E.; Newton, Robert U.; Cormie, Prue; Blazevich, Anthony J.

    2016-01-01

    Introduction: Tendon dynamics influence movement performance and provide the stimulus for long-term tendon adaptation. As tendon strain increases with load magnitude and decreases with loading rate, changes in movement speed during exercise should influence tendon strain. Methods: Ten resistance-trained men [squat one repetition maximum (1RM) to body mass ratio: 1.65 ± 0.12] performed parallel-depth back squat lifts with 60% of 1RM load at three different speeds: slow fixed-tempo (TS: 2-s eccentric, 1-s pause, 2-s concentric), volitional-speed without a pause (VS) and maximum-speed jump (JS). In each condition joint kinetics, quadriceps tendon length (LT), patellar tendon force (FT), and rate of force development (RFDT) were estimated using integrated ultrasonography, motion-capture, and force platform recordings. Results: Peak LT, FT, and RFDT were greater in JS than TS (p < 0.05), however no differences were observed between VS and TS. Thus, moving at faster speeds resulted in both greater tendon stress and strain despite an increased RFDT, as would be predicted of an elastic, but not a viscous, structure. Temporal comparisons showed that LT was greater in TS than JS during the early eccentric phase (10–14% movement duration) where peak RFDT occurred, demonstrating that the tendon's viscous properties predominated during initial eccentric loading. However, during the concentric phase (61–70 and 76–83% movement duration) differing FT and similar RFDT between conditions allowed for the tendon's elastic properties to predominate such that peak tendon strain was greater in JS than TS. Conclusions: Based on our current understanding, there may be an additional mechanical stimulus for tendon adaptation when performing large range-of-motion isoinertial exercises at faster movement speeds. PMID:27630574

  18. Medial versus lateral supraspinatus tendon properties: implications for double-row rotator cuff repair.

    Science.gov (United States)

    Wang, Vincent M; Wang, Fan Chia; McNickle, Allison G; Friel, Nicole A; Yanke, Adam B; Chubinskaya, Susan; Romeo, Anthony A; Verma, Nikhil N; Cole, Brian J

    2010-12-01

    Rotator cuff repair retear rates range from 25% to 90%, necessitating methods to improve repair strength. Although numerous laboratory studies have compared single-row with double-row fixation properties, little is known regarding regional (ie, medial vs lateral) suture retention properties in intact and torn tendons. A torn supraspinatus tendon will have reduced suture retention properties on the lateral aspect of the tendon compared with the more medial musculotendinous junction. Controlled laboratory study. Human supraspinatus tendons (torn and intact) were randomly assigned for suture retention mechanical testing, ultrastructural collagen fibril analysis, or histologic testing after suture pullout testing. For biomechanical evaluation, sutures were placed either at the musculotendinous junction (medial) or 10 mm from the free margin (lateral), and tendons were elongated to failure. Collagen fibril assessments were performed using transmission electron microscopy. Intact tendons showed no regional differences with respect to suture retention properties. In contrast, among torn tendons, the medial region exhibited significantly higher stiffness and work values relative to the lateral region. For the lateral region, work to 10-mm displacement (1592 ± 261 N-mm) and maximum load (265 ± 44 N) for intact tendons were significantly higher (P .05). Regression analyses for the intact and torn groups revealed generally low correlations between donor age and the 3 biomechanical indices. For both intact and torn tendons, the mean fibril diameter and area density were greater in the medial region relative to the lateral (P ≤ .05). In the lateral tendon, but not the medial region, torn specimens showed a significantly lower fibril area fraction (48.3% ± 3.8%) than intact specimens (56.7% ± 3.6%, P row after double-row repair. Larger diameter collagen fibrils as well as greater fibril area fraction in the medial supraspinatus tendon may provide greater resistance to

  19. The biomechanical effects of limb lengthening and botulinum toxin type A on rabbit tendon.

    Science.gov (United States)

    Olabisi, Ronke M; Best, Thomas M; Hurschler, Christof; Vanderby, Ray; Noonan, Kenneth J

    2010-12-01

    Numerous studies have examined the effects of distraction osteogenesis (DO) on bone, but relatively fewer have explored muscle adaptation, and even less have addressed the concomitant alterations that occur in the tendon. The purpose herein was to characterize the biomechanical properties of normal and elongated rabbit (N = 20) tendons with and without prophylactic botulinum toxin type A (BTX-A) treatment. Elastic and viscoelastic properties of Achilles and Tibialis anterior (TA) tendons were evaluated through pull to failure and stress relaxation tests. All TA tendons displayed nonlinear viscoelastic responses that were strain dependent. A power law formulation was used to model tendon viscoelastic responses and tendon elastic responses were fit with a microstructural model. Distraction-elongated tendons displayed increases in compliance and stress relaxation rates over undistracted tendons; BTX-A administration offset this result. The elastic moduli of distraction-lengthened TA tendons were diminished (p = 0.010) when distraction was combined with gastrocnemius (GA) BTX-A administration, elastic moduli were further decreased (p = 0.004) and distraction following TA BTX-A administration resulted in TA tendons with moduli not different from contralateral control (p > 0.05). Compared to contralateral control, distraction and GA BTX-A administration displayed shortened toe regions, (p = 0.031 and 0.038, respectively), while tendons receiving BTX-A in the TA had no differences in the toe region (p > 0.05). Ultimate tensile stress was unaltered by DO, but stress at the transition from the toe to the linear region of the stress-stretch curve was diminished in all distraction-elongated TA tendons (p properties. Copyright © 2010 Elsevier Ltd. All rights reserved.

  20. Tendinography for diagnosing injuries to tendons and ligaments

    International Nuclear Information System (INIS)

    Grevsten, S.; Eriksson, K.

    1979-01-01

    A radiographic method of tendinography is described. In rabbits no inflammatory reaction in the Achilles tendon was observed 12 to 15 days after injection of contrast medium. Effects of examination of two healthy subjects and a patient with a traumatic condition are described. Suitable amounts and concentrations of contrast medium for examinations of Achilies tendon and cruciate ligaments are discussed. (Auth.)

  1. Eccentric exercise: acute and chronic effects on healthy and diseased tendons.

    Science.gov (United States)

    Kjaer, Michael; Heinemeier, Katja M

    2014-06-01

    Eccentric exercise can influence tendon mechanical properties and matrix protein synthesis. mRNA for collagen and regulatory factors thereof are upregulated in animal tendons, independent of muscular contraction type, supporting the view that tendon, compared with skeletal muscle, is less sensitive to differences in type and/or amount of mechanical stimulus with regard to expression of collagen, regulatory factors for collagen, and cross-link regulators. In overused (tendinopathic) human tendon, eccentric exercise training has a beneficial effect, but the mechanism by which this is elicited is unknown, and slow concentric loading appears to have similar beneficial effects. It may be that tendinopathic regions, as long as they are subjected to a certain magnitude of load at a slow speed, independent of whether this is eccentric or concentric in nature, can reestablish their normal tendon fibril alignment and cell morphology. Copyright © 2014 the American Physiological Society.

  2. Biomechanical characteristics of the eccentric Achilles tendon exercise

    DEFF Research Database (Denmark)

    Henriksen, Marius; Aaboe, Jens; Bliddal, Henning

    2009-01-01

    that although the tendon loads are similar, the tendon is vibrated at higher frequencies during the eccentric phase than during the concentric phases. This study provides data that may explain the mechanisms behind the effectiveness of eccentric exercises used in the treatment of Achilles tendinopathies........ No differences in Achilles tendon loads were found. INTERPRETATION: This descriptive study demonstrates differences in the movement biomechanics between the eccentric and concentric phases of one-legged full weight bearing ankle dorsal and plantar flexion exercises. In particular, the findings imply......BACKGROUND: Eccentric exercise has been shown to provide good short-term clinical results in the treatment of painful mid-portion chronic Achilles tendinopathies. However, the mechanisms behind the positive effects of eccentric rehabilitation regimes are not known, and research...

  3. Muscle-tendon-related abnormalities detected by ultrasonography are common in symptomatic hip dysplasia

    DEFF Research Database (Denmark)

    Jacobsen, Julie Sandell; Bolvig, Lars; Hölmich, Per

    2018-01-01

    INTRODUCTION: Hip dysplasia is characterized by reduced acetabular coverage of the femoral head leading to an increased mechanical load on the hip joint and the acting hip muscles. Potentially, the muscles and tendons functioning close to the hip joint may present with overuse......-related ultrasonography findings. The primary aim was to report the prevalence of muscle-tendon-related abnormalities detected by ultrasonography in 100 patients with symptomatic hip dysplasia. The secondary aim was to investigate correlations between muscle-tendon-related abnormalities detected by ultrasonography......-tendon-related abnormalities detected by ultrasonography in the hip and groin region are common in patients with symptomatic hip dysplasia, and the ultrasonography findings of the iliopsoas and gluteus medius/minimus tendons are weakly to moderately correlated to pain related to muscles and tendons in these structures. Both...

  4. Improved Achilles tendon healing by early mechanical loading in a rabbit model.

    Science.gov (United States)

    Wang, Jihong; Jiang, Dianming; Wen, Shuzheng; Jing, Shangfei; Fan, Dongsheng; Hao, Zengtao; Han, Chaoqian

    2015-01-01

    To investigate the structure and the attachment strength of a healing tendon-bone interface and the role of mechanical loading in tendon healing. Sixty rabbits underwent unilateral detachment and repair of the Achilles tendon. Thirty animals were immobilized (Group A), and the others wereallowed loadingimmediately postoperatively (Group B). Animals were sacrificed at 4 weeks and evaluated for histological and biomechanical testing. Statistical analysis was performed with an independent t test with significance set at P = 0.05. The ultimate stress was greater in group B (4.598 ± 1.321 N/mm(2)) compared with the control group (3.388 ± 0.994 N/mm(2)) (P tendon-to-bone interface with a larger area of chondrocytes was found in group B (P tendon-to-bone interface.

  5. Bilateral giant cell tumor of tendon sheath of tendoachilles

    Directory of Open Access Journals (Sweden)

    Soma Datta

    2014-01-01

    Full Text Available Giant cell tumor of tendon sheath arises from the synovium of tendon sheaths, joints, or bursae, mostly affects adults between 30 and 50 years of age, and is slightly more common in females. We report the case of a 32-years-old male presenting with pain in both ankles without any history of trauma. On clinical examination, tenderness on both tendoachilles and local thickening were observed. Ultrasonography showed thickening of local tendinous area with increase in anteroposterior diameter, and Doppler demonstrated increased flow in peritendinous area. MRI findings showed that most of the tumor had intermediate signal intensity and portions of the tumor had low signal intensity. Fine needle aspiration cytology confirmed the diagnosis of giant cell tumor of tendon sheath. Excision biopsy was done with no recurrence on five month follow-up. Review of literature did not reveal any similar result; so, bilateral giant cell tumor of tendon sheath of tendoachilles is a rare presentation.

  6. Renal vessel reconstruction in kidney transplantation using a polytetrafluoroethylene (PTFE) vascular graft.

    Science.gov (United States)

    Kamel, Mohamed H; Thomas, Anil A; Mohan, Ponnusamy; Hickey, David P

    2007-04-01

    We report a rare experience in reconstructing short renal vessels in kidney transplantation using polytetrafluroethylene (PTFE) vascular grafts. The short renal vessels in three kidney grafts were managed by the interposition of PTFE vascular grafts. Two grafts were from deceased donors and the third was a renal auto-transplant graft. PTFE grafts were used to lengthen short renal veins in two kidney grafts and a short renal artery in one. The warm ischaemia time was under 1 h and all kidneys functioned well post-operatively. Excellent blood perfusion in the three renal grafts was present on postoperative MAG 3 renal scan. No intra-operative or post-operative complications were encountered. In the three described patients, the use of PTFE vascular graft presented no additional morbidity to the kidney transplant operation and no post-oerative complication was related to its use. However, more data are necessary to conclude that PTFE graft can be used safely in kidney transplantation.

  7. Palmar reconstruction of the triangular fibrocartilage complex for instability of the distal radioulnar joint: a biomechanical study.

    Science.gov (United States)

    Kataoka, T; Moritomo, H; Omokawa, S; Iida, A; Wada, T; Aoki, M

    2013-06-01

    We developed a new triangular fibrocartilage complex reconstruction technique for distal radioulnar joint instability in which the palmar portion of the triangular fibrocartilage complex was predominantly reconstructed, and evaluated whether such reconstruction can restore stability of the distal radioulnar joint in seven fresh cadaver upper extremities. Distal radioulnar joint instability was induced by cutting all soft-tissue stabilizers around the distal ulna. Using a palmar approach, a palmaris longus tendon graft was sutured to the remnant of the palmar radioulnar and ulnocarpal ligaments. The graft was then passed through a bone tunnel created at the fovea and was sutured. Loads were applied to the radius, and dorsopalmar displacements of the radius relative to the ulna were measured using an electromagnetic tracking device in neutral rotation, 60° supination and 60° pronation. We compared the dorsopalmar displacements before sectioning, before reconstruction and after reconstruction. Dorsopalmar instability produced by sectioning significantly improved in all forearm positions after reconstruction.

  8. Spontaneous Achilles tendon rupture in alkaptonuria

    Directory of Open Access Journals (Sweden)

    Omar A. Alajoulin

    2015-12-01

    Full Text Available Alkaptonuria (AKU is a rare inborn metabolic disease characterized by accumulation of homogentisic acid (HGA. Excretion of HGA in urine causes darkening of urine and its deposition in connective tissues causes dark pigmentation (ochronosis, early degeneration of articular cartilage, weakening of the tendons, and subsequent rupture. In this case report, we present a rare case of a patient presented with unilateral spontaneous rupture of Achilles tendon due to AKU. The patient developed most of the orthopedic manifestations of the disease earlier than typical presentations. Alkaptonuria patients should avoid strenuous exercises and foot straining especially in patients developing early orthopedic manifestations.

  9. Spontaneous Achilles tendon rupture in alkaptonuria.

    Science.gov (United States)

    Alajoulin, Omar A; Alsbou, Mohammed S; Ja'afreh, Somayya O; Kalbouneh, Heba M

    2015-12-01

    Alkaptonuria (AKU) is a rare inborn metabolic disease characterized by accumulation of homogentisic acid (HGA). Excretion of HGA in urine causes darkening of urine and its deposition in connective tissues causes dark pigmentation (ochronosis), early degeneration of articular cartilage, weakening of the tendons, and subsequent rupture. In this case report, we present a rare case of a patient presented with unilateral spontaneous rupture of Achilles tendon due to AKU. The patient developed most of the orthopedic manifestations of the disease earlier than typical presentations. Alkaptonuria patients should avoid strenuous exercises and foot straining especially in patients developing early orthopedic manifestations.

  10. CT of peroneal tendon injury in patients with calcaneal fractures

    International Nuclear Information System (INIS)

    Rosenberg, Z.S.; Feldman, F.; Singson, R.D.

    1986-01-01

    Injury to the peroneal tendons is a major complication of intraarticular calcaneal fractures. Heretofore, the injury has been difficult to diagnose by routine imaging modalities. However, CT studies of 24 intraarticular calcaneal fractures revealed evidence of peroneal tendon injury in 22 cases. The pathologic conditions included lateral displacement, subluxation, dislocation, and impingement on the tendons by bony fragments, hematomas, and scar tissue. Patients studied 6-12 months after injury had CT evidence consistent with clinical symptoms of peroneal tenosynovitis. Since peroneal tendon injury is surgically correctable, it should be differentiated from other known and more obvious complications, of calcaneal fractures. CT therefore serves as a valuable, noninvasive tool in evaluating these otherwise nonvisualized soft tissue structures in the immediate posttraumatic period as well as during long-term follow up

  11. Magnetic resonance imaging of Achilles tendon xanthomas in familial hypercholesterolemia

    International Nuclear Information System (INIS)

    Liem, M.S.L.; Bloem, J.L.; Schipper, J.

    1992-01-01

    The demonstration of tendon xanthomas is helpful in diagnosing heterozygous familial hypercholesterolemia. We investigated the possibility the lipid element with magnetic resonance (MR) imaging in seven patients with familial hypercholesterolemia and six controls. Although the mean relative signal intensities measured on long TR/TE spin echo sequences of the tendon were significantly higher in patients than in controls, the lack of such elevation does not rule out the presence of such lesions. MR imaging and US provide equal information on the anatomy of the Achilles tendon; as an abnormally increased signal intensity within the xanthoma on MRI was found in only a minority of our patients, the value of MRI in the demonstration of Achilles tendon xanthomas is limited when using conventional T1 and T2 spin echo sequences. (orig./DG)

  12. [Achilles tendon xanthoma imaging on ultrasound and magnetic resonance imaging].

    Science.gov (United States)

    Fernandes, Eloy de Ávila; Santos, Eduardo Henrique Sena; Tucunduva, Tatiana Cardoso de Mello; Ferrari, Antonio J L; Fernandes, Artur da Rocha Correa

    2015-01-01

    The Achilles tendon xanthoma is a rare disease and has a high association with primary hyperlipidemia. An early diagnosis is essential to start treatment and change the disease course. Imaging exams can enhance diagnosis. This study reports the case of a 60-year-old man having painless nodules on his elbows and Achilles tendons without typical gout crisis, followed in the microcrystalline disease clinic of Unifesp for diagnostic workup. Laboratory tests obtained showed dyslipidemia. The ultrasound (US) showed a diffuse Achilles tendon thickening with hypoechoic areas. Magnetic resonance imaging (MRI) showed a diffuse tendon thickening with intermediate signal areas, and a reticulate pattern within. Imaging studies showed relevant aspects to diagnose a xanthoma, thus helping in the differential diagnosis. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  13. 77 FR 69508 - Inservice Inspection of Prestressed Concrete Containment Structures With Grouted Tendons

    Science.gov (United States)

    2012-11-19

    ... Containment Structures With Grouted Tendons AGENCY: Nuclear Regulatory Commission. ACTION: Regulatory guide... (RG) 1.90, ``Inservice Inspection of Prestressed Concrete Containment Structures with Grouted Tendons... appropriate surveillance program for prestressed concrete containment structures with grouted tendons...

  14. Quantification of Internal Stress-Strain Fields in Human Tendon: Unraveling the Mechanisms that Underlie Regional Tendon Adaptations and Mal-Adaptations to Mechanical Loading and the Effectiveness of Therapeutic Eccentric Exercise

    Science.gov (United States)

    Maganaris, Constantinos N.; Chatzistergos, Panagiotis; Reeves, Neil D.; Narici, Marco V.

    2017-01-01

    By virtue of their anatomical location between muscles and bones, tendons make it possible to transform contractile force to joint rotation and locomotion. However, tendons do not behave as rigid links, but exhibit viscoelastic tensile properties, thereby affecting the length and contractile force in the in-series muscle, but also storing and releasing elastic stain energy as some tendons are stretched and recoiled in a cyclic manner during locomotion. In the late 90s, advancements were made in the application of ultrasound scanning that allowed quantifying the tensile deformability and mechanical properties of human tendons in vivo. Since then, the main principles of the ultrasound-based method have been applied by numerous research groups throughout the world and showed that tendons increase their tensile stiffness in response to exercise training and chronic mechanical loading, in general, by increasing their size and improving their intrinsic material. It is often assumed that these changes occur homogenously, in the entire body of the tendon, but recent findings indicate that the adaptations may in fact take place in some but not all tendon regions. The present review focuses on these regional adaptability features and highlights two paradigms where they are particularly evident: (a) Chronic mechanical loading in healthy tendons, and (b) tendinopathy. In the former loading paradigm, local tendon adaptations indicate that certain regions may “see,” and therefore adapt to, increased levels of stress. In the latter paradigm, local pathological features indicate that certain tendon regions may be “stress-shielded” and degenerate over time. Eccentric exercise protocols have successfully been used in the management of tendinopathy, without much sound understanding of the mechanisms underpinning their effectiveness. For insertional tendinopathy, in particular, it is possible that the effectiveness of a loading/rehabilitation protocol depends on the topography

  15. Structure and component alteration of rabbit Achilles tendon in tissue culture.

    Science.gov (United States)

    Hosaka, Yoshinao; Ueda, Hiromi; Yamasaki, Tadatsugu; Suzuki, Daisuke; Matsuda, Naoya; Takehana, Kazushige

    2005-12-01

    The aim of this study was to investigate alterations of cultured tendon tissues to determine whether tissue culture is a useful method for biological analyses of the tendon. Tendon tissues for tissue culture were isolated from Achilles tendons of rabbits. The tendon segments were placed one segment per well and incubated in growth medium consisting of Dullbecco's modified Eagle's medium supplemented with 5% fetal bovine serum at 37 degrees C in a humidified atmosphere with 5% CO(2) for various periods. The alignment of collagen fibrils was preserved for 48 h, but tendon structure has disintegrated at 96 h. Alcian blue staining and gelatine zymography revealed that proteoglycan markedly diminished and that matrix metalloproteinase (MMPs) activity was upregulated sharply at 72 and 96 h. The ratio of collagen fibrils with large diameter had increased and the mean diameter and mass average diameter value had reached maximum at 48 h. The values then decreased and mean diameters at 72 and 96 h were significantly different from that at 48 h. At 96 h, the ratio of collagen fibrils with small diameters had increased and collagen fibrils with large diameters had disappeared. These findings indicate that structural alteration is possible to be induced by disintegration of collagen fibrils and disappearance of glycosaminoglycans from extracellular matrix (ECM), subsequent of upregulation of MMPs activity. Although the study period is limited, the tissue culture method is available for investigating cell-ECM interaction in tendons.

  16. Sensitivity of physical examination versus arthroscopy in diagnosing subscapularis tendon injury.

    Science.gov (United States)

    Faruqui, Sami; Wijdicks, Coen; Foad, Abdullah

    2014-01-01

    The purpose of this study was to examine the accuracy of physical examination in the detection of subscapularis tendon tears and compare it with the gold standard of arthroscopy to determine whether clinical examination can reliably predict the presence of subscapularis tendon tears. This was a retrospective analysis of 52 patients (52 shoulders) who underwent arthroscopic subscapularis tendon repairs between September 2008 and April 2012. Positive findings on any combination of the belly press, lift-off, and bear hug tests constituted a positive physical examination result. There was a positive finding on physical examination in 42 of 52 patients. The sensitivity of the physical examination as a whole was 81%. The literature has shown that the belly press, bear hug, and lift-off tests are specific to the subscapularis tendon. To the authors’ knowledge, this is the first study to evaluate the sensitivity of these 3 separate clinical tests as a composite. Knowledge regarding the sensitivity of the subscapularis-specific physical examination as a composite can lead practitioners to implement all 3 components, even when 1 test has a negative finding, thus promoting a more thorough physical examination. Because unrepaired subscapularis tendon tears can result in poor outcomes in the repair of other rotator cuff tendons, a complete physical examination would be beneficial to patients with shoulder pathology. The authors conclude that physical examination, when performed consistently by an experienced practitioner, can reliably predict the presence of subscapularis tendon tears.

  17. Atelocollagen Enhances the Healing of Rotator Cuff Tendon in Rabbit Model.

    Science.gov (United States)

    Suh, Dong-Sam; Lee, Jun-Keun; Yoo, Ji-Chul; Woo, Sang-Hun; Kim, Ga-Ram; Kim, Ju-Won; Choi, Nam-Yong; Kim, Yongdeok; Song, Hyun-Seok

    2017-07-01

    Failure of rotator cuff healing is a common complication despite the rapid development of surgical repair techniques for the torn rotator cuff. To verify the effect of atelocollagen on tendon-to-bone healing in the rabbit supraspinatus tendon compared with conventional cuff repair. Controlled laboratory study. A tear of the supraspinatus tendon was created and repaired in 46 New Zealand White rabbits. They were then randomly allocated into 2 groups (23 rabbits per group; 15 for histological and 8 for biomechanical test). In the experimental group, patch-type atelocollagen was implanted between bone and tendon during repair; in the control group, the torn tendon was repaired without atelocollagen. Each opposite shoulder served as a sham (tendon was exposed only). Histological evaluation was performed at 4, 8, and 12 weeks. Biomechanical tensile strength was tested 12 weeks after surgery. Histological evaluation scores of the experimental group (4.0 ± 1.0) were significantly superior to those of the control group (7.7 ± 2.7) at 12 weeks ( P = .005). The load to failure was significantly higher in the experimental group (51.4 ± 3.9 N) than in the control group (36.4 ± 5.9 N) ( P = .001). Histological and biomechanical studies demonstrated better results in the experimental group using atelocollagen in a rabbit model of the supraspinatus tendon tear. Atelocollagen patch could be used in the cuff repair site to enhance healing.

  18. Spontaneous Rupture of the Extensor Pollicis Longus Tendon due to Unusual Etiology

    Directory of Open Access Journals (Sweden)

    Süleyman Taş

    2014-03-01

    Full Text Available Background: The etiology of spontaneous rupture of the extensor pollicis longus tendon includes systemic or local steroid injections, wrist fracture, tenosynovitis, synovitis, rheumatoid arthritis, and repetitive wrist motions. Case Report: We encountered a case of extensor pollicis longus tendon rupture with an unusual etiology, cow milking. In this case, transfer of the extensor indicis proprius tendon was performed successfully. At 1 year after surgery, extension of the thumb was sufficient. Conclusion: It appears that patients with occupations involving repetitive motions are at a high risk of closed tendon ruptures.

  19. Mechanoreceptors of the Achilles tendon: a histomorphological study in pigs with clinical significance for humans.

    Science.gov (United States)

    Kapetanakis, Stylianos; Gkasdaris, Grigorios; Daneva, Eleni; Givissis, Panagiotis; Papathanasiou, Jannis; Xanthos, Theodoros

    2017-01-01

    Tendons contain neurosensory elements called mechanoreceptors which contribute to the neuromuscular system as sources of reflex signals. The literature is lacking in histological assessment of mechanoreceptors of the Achilles tendon in piglets and our aim was to indicate their types, location and quantity. The study was performed using histological tissue samples from the Achilles tendon of ten healthy pigs, five left, five right, six males, four females. The samples were taken up to 12 hours after death. Immediately after removal, the tendons were placed in the laboratory where sections were taken and examined microscopically. The tendons were stained with the gold chloride method. The results showed that Golgi tendon organs, free nerve endings and Pacinian-like corpuscles were found in the Achilles tendon of pigs. Most structures were near the osteotendinous and myotendinous junctions, away from the middle portion of the tendon. As shown in other studies and similarly in ours, mechanoreceptors tend to be close to the distant thirds and not in the middle third of the tendon. This study could have clinical application on human Achilles tendon and its repair after damage. IV.

  20. management of open achilles tendon injury: primary repair and early ...

    African Journals Online (AJOL)

    is attributable to increase in both competitive and recreational sports. In most of the literature written on Achilles tendon injuries there were rarely any information about open Achilles tendon ... The most common aetiology was motorbike spoke.