WorldWideScience

Sample records for reconstruction tendon interposition

  1. Magnetic resonance imaging appearance of the flexor carpi radialis tendon after harvest in ligamentous reconstruction tendon interposition arthroplasty

    International Nuclear Information System (INIS)

    Beall, Douglas P.; Fish, Jon R.; Ritchie, Eric R.; Tran, Hoang N.; Ingari, John V.; Campbell, Scot E.; Grayson, David E.; Sanders, Timothy G.; Mundis, Gregory; Lehman, Thomas P.

    2006-01-01

    To determine whether the post-harvest magnetic resonance (MR) imaging appearance of flexor carpi radialis (FCR) tendons, harvested during ligamentous reconstruction tendon interposition (LRTI) of the thumb carpometacarpal (CMC) joint arthroplasty, is consistent with tendon regeneration. Operative reports and patient medical records for all patients undergoing LRTI arthroplasty between 1995 and 2003 at our institution were reviewed. MR images of the patients' forearms and wrists were obtained and interpreted by two musculoskeletal radiologists. Using the flexor carpi ulnaris (FCU) tendon as an internal standard, the extent of FCR tendon regeneration was expressed as a percentage by dividing the volume of regenerated FCR tendon by the volume of the FCU tendon. Fourteen patients who had the full thickness of the FCR tendon harvested and who were available for MR imaging were identified and included in the study. At least partial regeneration of the FCR tendon occurred in 11 of the 14 patients (79%). Of these, 2 patients (14%), demonstrated complete, or nearly complete regeneration. Partial regeneration of the FCR tendon was seen in 9 of the 14 patients (64%). In 3 patients (21%), there was no appreciable regeneration of the FCR tendon. Among patients who underwent full-thickness harvest of the FCR tendon for LRTI arthroplasty of the first CMC joint, the follow-up MR imaging appearance of the flexor carpi radialis tendon was consistent with tendon regeneration in 79% of those examined. (orig.)

  2. Tendon Interposition and Ligament Reconstruction with ECRL Tendon in the Late Stages of Kienböck’s Disease: A Cadaver Study

    Directory of Open Access Journals (Sweden)

    Nazım Karalezli

    2013-01-01

    Full Text Available Background. The optimal surgical treatment for Kienböck’s disease with stages IIIB and IV remains controversial. A cadaver study was carried out to evaluate the use of coiled extensor carpi radialis longus tendon for tendon interposition and a strip obtained from the same tendon for ligament reconstruction in the late stages of Kienböck’s disease. Methods. Coiled extensor carpi radialis longus tendon was used to fill the cavity of the excised lunate, and a strip obtained from this tendon was sutured onto itself after passing through the scaphoid and the triquetrum acting as a ligament to preserve proximal row integrity. Biomechanical tests were carried out in order to evaluate this new ligamentous reconstruction. Results. It was biomechanically confirmed that the procedure was effective against axial compression and distributed the upcoming mechanical stress to the distal row. Conclusion. Extensor carpi radialis longus tendon has not been used for tendon interposition and ligament reconstruction in the treatment of this disease before. In view of the biomechanical data, the procedure seems to be effective for the stabilization of scaphoid and carpal bones.

  3. Effect of the Interposition of Calcium Phosphate Materials on Tendon-Bone Healing During Repair of Chronic Rotator Cuff Tear.

    Science.gov (United States)

    Zhao, Song; Peng, Lingjie; Xie, Guoming; Li, Dingfeng; Zhao, Jinzhong; Ning, Congqin

    2014-08-01

    The current nature of tendon-bone healing after rotator cuff (RC) repair is still the formation of granulation tissue at the tendon-bone interface rather than the formation of fibrocartilage, which is the crucial structure in native tendon insertion and can be observed after knee ligament reconstruction. The interposition of calcium phosphate materials has been found to be able to enhance tendon-bone healing in knee ligament reconstruction. However, whether the interposition of these kinds of materials can enhance tendon-bone healing or even change the current nature of tendon-bone healing after RC repair still needs to be explored. The interposition of calcium phosphate materials during RC repair would enhance tendon-bone healing or change its current nature of granulation tissue formation into a more favorable process. Controlled laboratory study. A total of 144 male Sprague-Dawley rats underwent unilateral detachment of the supraspinatus tendon, followed by delayed repair after 3 weeks. The animals were allocated into 1 of 3 groups: (1) repair alone, (2) repair with Ca5(PO4)2SiO4 (CPS) bioceramic interposition, or (3) repair with hydroxyapatite (HA) bioceramic interposition at the tendon-bone interface. Animals were sacrificed at 2, 4, or 8 weeks postoperatively, and microcomputed tomography (micro-CT) was used to quantify the new bone formation at the repair site. New fibrocartilage formation and collagen organization at the tendon-bone interface was evaluated by histomorphometric analysis. Biomechanical testing of the supraspinatus tendon-bone complex was performed. Statistical analysis was performed using 1-way analysis of variance. Significance was set at P repair, CPS bioceramic significantly increased the area of fibrocartilage at the tendon-bone interface compared with the control and HA groups. Moreover, CPS and HA bioceramics had significantly improved collagen organization. Biomechanical tests indicated that the CPS and HA groups have greater ultimate

  4. Stability of double-row rotator cuff repair is not adversely affected by scaffold interposition between tendon and bone.

    Science.gov (United States)

    Beitzel, Knut; Chowaniec, David M; McCarthy, Mary Beth; Cote, Mark P; Russell, Ryan P; Obopilwe, Elifho; Imhoff, Andreas B; Arciero, Robert A; Mazzocca, Augustus D

    2012-05-01

    Rotator cuff reconstructions may be improved by adding growth factors, cells, or other biologic factors into the repair zone. This usually requires a biological carrier (scaffold) to be integrated into the construct and placed in the area of tendon-to-bone healing. This needs to be done without affecting the constructs mechanics. Hypothesis/ The hypothesis was that scaffold placement, as an interposition, has no adverse effects on biomechanical properties of double-row rotator cuff repair. The purpose of this study was to examine the effect of scaffold interposition on the initial strength of rotator cuff repairs. Controlled laboratory study. Twenty-five fresh-frozen shoulders (mean age: 65.5 ± 8.9 years) were randomly assigned to 5 groups. Groups were chosen to represent a broad spectrum of commonly used scaffold types: (1) double-row repair without augmentation, (2) double-row repair with interposition of a fibrin clot (Viscogel), (3) double-row repair with interposition of a collagen scaffold (Mucograft) between tendon and bone, (4) double-row repair with interposition of human dermis patch (ArthroFlex) between tendon and bone, and (5) double-row repair with human dermis patch (ArthroFlex) placed on top of the repair. Cyclic loading to measure displacement was performed to 3000 cycles at 1 Hz with an applied 10- to 100-N load. The ultimate load to failure was determined at a rate of 31 mm/min. There were no significant differences in mean displacement under cyclic loading, slope, or energy absorbed to failure between all groups (P = .128, P = .981, P = .105). Ultimate load to failure of repairs that used the collagen patch as an interposition (573.3 ± 75.6 N) and a dermis patch on top of the reconstruction (575.8 ± 22.6 N) was higher compared with the repair without a scaffold (348.9 ± 98.8 N; P = .018 and P = .025). No significant differences were found for repairs with the fibrin clot as an interposition (426.9 ± 103.6 N) and the decellularized dermis

  5. Biomechanical comparison of expanded polytetrafluoroethylene (ePTFE) and PTFE interpositional patches and direct tendon-to-bone repair for massive rotator cuff tears in an ovine model.

    Science.gov (United States)

    McKeown, Andrew Dj; Beattie, Rebekah F; Murrell, George Ac; Lam, Patrick H

    2016-01-01

    Massive irreparable rotator cuff tears are a difficult problem. Modalities such as irrigation and debridement, partial repair, tendon transfer and grafts have been utilized with high failure rates and mixed results. Synthetic interpositional patch repairs are a novel and increasingly used approach. The present study aimed to examine the biomechanical properties of common synthetic materials for interpositional repairs in contrast to native tendon. Six ovine tendons, six polytetrafluoroethylene (PTFE) felt sections and six expanded PTFE (ePTFE) patch sections were pulled-to-failure to analyze their biomechanical and material properties. Six direct tendon-to-bone surgical method repairs, six interpositional PTFE felt patch repairs and six interpositional ePTFE patch repairs were also constructed in ovine shoulders and pulled-to-failure to examine the biomechanical properties of each repair construct. Ovine tendon had higher load-to-failure (591 N) and had greater stiffness (108 N/mm) than either PTFE felt (296 N, 28 N/mm) or ePTFE patch sections (323 N, 34 N/mm). Both PTFE felt and ePTFE repair techniques required greater load-to-failure (225 N and 177 N, respectively) than direct tendon-to-bone surgical repairs (147 N) in ovine models. Synthetic materials lacked several biomechanical properties, including strength and stiffness, compared to ovine tendon. Interpositional surgical repair models with these materials were significantly stronger than direct tendon-to-bone model repairs.

  6. Quadriceps Tendon Autograft Medial Patellofemoral Ligament Reconstruction.

    Science.gov (United States)

    Fink, Christian; Steensen, Robert; Gföller, Peter; Lawton, Robert

    2018-06-01

    Critically evaluate the published literature related to quadriceps tendon (QT) medial patellofemoral ligament (MPFL) reconstruction. Hamstring tendon (HT) MPFL reconstruction techniques have been shown to successfully restore patella stability, but complications including patella fracture are reported. Quadriceps tendon (QT) reconstruction techniques with an intact graft pedicle on the patella side have the advantage that patella bone tunnel drilling and fixation are no longer needed, reducing risk of patella fracture. Several QT MPFL reconstruction techniques, including minimally invasive surgical (MIS) approaches, have been published with promising clinical results and fewer complications than with HT techniques. Parallel laboratory studies have shown macroscopic anatomy and biomechanical properties of QT are more similar to native MPFL than hamstring (HS) HT, suggesting QT may more accurately restore native joint kinematics. Quadriceps tendon MPFL reconstruction, via both open and MIS techniques, have promising clinical results and offer valuable alternatives to HS grafts for primary and revision MPFL reconstruction in both children and adults.

  7. Interposition of Ileal J-Pouch for Rectum Reconstruction in Dog

    Directory of Open Access Journals (Sweden)

    Leila Ghahramani

    2014-03-01

    Full Text Available Background: The gold standard of the management of rectal cancer in the middle and lower parts is low anterior resection with coloanal anastomosis. About 50% of the patients undergoing this procedure might experience some complications because of the low capacity of the neorectum. The aim of this study was to evaluate ileal J-pouch interposition as a neorectum between the anal canal and the remaining colon in comparison to coloanal anastomosis and transverse coloplasty. Methods: Twelve dogs, weighing 23-27 kg, were divided into three groups. After laparotomy, the volume of the primary rectum was measured so that it could be compared with that of the neorectum at the end of the study. After rectal resection in Group A, the colon was directly anastomosed to the anus. In Group B, a 5-cm longitudinal incision was made 2 cm proximal to the anastomosis and was sutured transversely (coloplasty. In Group C, a 5-cm ileal J-pouch was interposed between the colon and anus. After 8 weeks, the neorectum was evaluated for volume, radiology, and pathology. Results: All the samples were alive until the end of the study. The healing of the anastomotic lines was acceptable (pathologically in all. The mean volume expansion was 20.9% in Group A, 21.7% in Group B, and 118.2% in Group C, with the latter being significantly higher than that of the other groups (P=0.03. Colon J-pouch and coloplasty after proctectomy in some situations have not been performable. This study evaluated the performance of ileal J-pouch interposition. Conclusion: This study showed that ileal J-pouch interposition might produce an acceptable reservoir function and that it seems feasible and safe in selected cases. Please cite this article as: Ghahramani L, Yazdani S, Derakhshani S, Rezaianzadeh A, Jalli R, Geramizadeh B, Safarpour AR, Rahimikazerooni S, Hosseini SV. Interposition of Ileal J-Pouch for Rectum Reconstruction in Dog. Iran J Med Sci. 2014;39(2:117-122.

  8. Postoperative US of leg tendon reconstruction

    International Nuclear Information System (INIS)

    Draghi, F.; Calliada, F.; Fulle, I.; Madonia, L.; Bottinelli, O.; Campani, R.

    1999-01-01

    The role of ultrasound (US) in the postoperative assessment of tendon reconstruction is not clearly defined and there is non systematic arrangement of US patterns. The authors examined 34 patients submitted to surgery or conservative treatment for total/partial tear or musculotendinous detachment of patellar or Achilles tendon in the last 5 years. All patients underwent physical and US examinations. The surgical tendon exhibited the same US patterns in 23/28 patients: it was markedly enlarged (three-/fourfold the normal diameter) and more rounded, with inhomogeneous and hypoechoic appearance not only at the tear/surgical site but also above and below it, for some cm. Small hyperechoic images, mainly dots, were seen in 19 cases, which were referable to small calcifications and stitches. More and larger calcifications were found in 8 patients, where they were associated with anechoic degeneration areas. Color Doppler US showed moderate or strong hypervascularization around the tear in the first months post injury. US patterns did not correlate with physical findings, but color Doppler patterns did. In 6 cases of musculotendinous detachment submitted to conservative treatment, US showed enlargement and hypoechogenicity in the injury site only, with no involvement of the remaining tendon. US was also used to time and guide drainage of perilesional hematomas, which were often quite large. US is the method of choice in the postoperative follow-up of tendon tears and musculotendinous detachments because it shows abnormal signs which are missed at clinics and provides additional information needed for treatment planning [it

  9. Abductor pollicis longus tendon interposition for arthrosis of the first carpo-metacarpal joint. Long-term results.

    Science.gov (United States)

    Lied, Line; Bjørnstad, Kari; Woje, Ann K N; Finsen, Vilhjalmur

    2016-02-01

    We performed an interposition arthroplasty using the abductor pollicis longus tendon for arthrosis in the basal joint of the thumb that needed surgery from 1995 to 2010. In 2001 47 patients (55 thumbs) were reviewed after 3.5 (1-5) years. The pain relief was excellent in 32 thumbs, and 25 patients improved their ability to perform daily tasks. Mobility was well preserved. Key pinch and grip strengths averaged 78% and 89%, respectively, of those in unaffected hands. We have now re-examined all 33 available patients (36 thumbs) 11-14 years after surgery. Fourty one of the originally examined patients were still alive. Seven were too ill to attend a follow-up and one refused. The remainder were examined in a fashion as similar as possible to that at the original review. The patients' subjective estimations of pain during the last week and satisfaction with the cosmetic and general results were recorded on visual analogue scales. The patients' ability to perform various activities of daily living were recorded and they completed the Disability of the arm, shoulder and hand (DASH) questionnaire. The mobility of the wrist and abduction of the thumb of the operated hands were recorded with a goniometer. Grip and pinch strength were measured and new radiographs were obtained. Key pinch strength had increased significantly over the last 10 years. The mobility was still good, except for thumb abduction, which had decreased with time. The median DASH score had fallen from 28 to 20 between the two reviews. There was insignificant further median loss of distance between the scaphoid and the metacarpal since the earlier review. The good results of this procedure found soon after surgery are maintained long-term.

  10. Ipsilateral free semitendinosus tendon graft transfer for reconstruction of chronic tears of the Achilles tendon

    Directory of Open Access Journals (Sweden)

    Gougoulias Nikolaos

    2008-07-01

    Full Text Available Abstract Background Many techniques have been developed for the reconstruction of the Achilles tendon in chronic tears. In presence of a large gap (greater than 6 centimetres, tendon augmentation is required. Methods We present our method of minimally invasive semitendinosus reconstruction for the Achilles tendon using one para-midline and one midline incision. Results The first incision is a 5 cm longitudinal incision, made 2 cm proximal and just medial to the palpable end of the residual tendon. The second incision is 3 cm long and is also longitudinal but is 2 cm distal and in the midline to the distal end of the tendon rupture. The distal and proximal Achilles tendon stumps are mobilised. After trying to reduce the gap of the ruptured Achilles tendon, if the gap produced is greater than 6 cm despite maximal plantar flexion of the ankle and traction on the Achilles tendon stumps, the ipsilateral semitendinosus tendon is harvested. The semitendinosus tendon is passed through small incisions in the substance of the proximal stump of the Achilles tendon, and it is sutured to the Achilles tendon. It is then passed beneath the intact skin bridge into the distal incision, and passed from medial to lateral through a transverse tenotomy in the distal stump. With the ankle in maximal plantar flexion, the semitendinosus tendon is sutured to the Achilles tendon at each entry and exit point Conclusion This minimally invasive technique allows reconstruction of the Achilles tendon using the tendon of semitendinosus preserving skin integrity over the site most prone to wound breakdown, and can be especially used to reconstruct the Achilles tendon in the presence of large gap (greater than 6 centimetres.

  11. Salvage reconstruction of failed interposition arthroplasty at the base of the thumb.

    Science.gov (United States)

    Braun, Richard M; Rechnic, Mark; Shah, Kalpit N

    2012-12-01

    We present an operative procedure designed to revise a failed arthroplasty at the base of the thumb. This report describes a reliable operation that corrects residual instability and malignment which results in thumbs that are weak and painful despite a previous procedure. The operation has also been used as a primary procedure for arthritis of the trapeziometacarpal joint where instability and subluxation was a major component of the problem requiring joint reconstruction. The unique features of this procedure include a reinforced double-thickness tendon graft, a unique tendon anchor, and a fascia lata allograft spacer. Significant functional improvement is anticipated when joint reconstruction provides increased proximal stability. Pinch and grip measurements improve. Pain scores also diminish after the operation. Hand function and patient satisfaction can be substantially improved with revision arthroplasty when the initial operation has failed to provide a thumb that is mobile, stable, and pain free. The technical features of the procedure address reduction of malignment, restoring of anatomic balance, and secure fixation of the proximal apex of the thumb metacarpal which restores thumb reduction position and digital balance.

  12. Interposition of Ileal J-Pouch for Rectum Reconstruction in Dog

    OpenAIRE

    Leila Ghahramani; Saeed Yazdani; Saeed Derakhshani; Abbas Rezaianzadeh; Reza Jalli; Bita Geramizadeh; Ali Reza Safarpour; Salar Rahimikazerooni; Seyed Vahid Hosseini

    2014-01-01

    Background: The gold standard of the management of rectal cancer in the middle and lower parts is low anterior resection with coloanal anastomosis. About 50% of the patients undergoing this procedure might experience some complications because of the low capacity of the neorectum. The aim of this study was to evaluate ileal J-pouch interposition as a neorectum between the anal canal and the remaining colon in comparison to coloanal anastomosis and transverse coloplasty. Methods: Twelve do...

  13. Interposition of Ileal J-Pouch for Rectum Reconstruction in Dog

    Science.gov (United States)

    Ghahramani, Leila; Yazdani, Saeed; Derakhshani, Saeed; Rezaianzadeh, Abbas; Jalli, Reza; Geramizadeh, Bita; Safarpour, Ali Reza; Rahimikazerooni, Salar; Hosseini, Seyed Vahid

    2014-01-01

    Background: The gold standard of the management of rectal cancer in the middle and lower parts is low anterior resection with coloanal anastomosis. About 50% of the patients undergoing this procedure might experience some complications because of the low capacity of the neorectum. The aim of this study was to evaluate ileal J-pouch interposition as a neorectum between the anal canal and the remaining colon in comparison to coloanal anastomosis and transverse coloplasty. Methods: Twelve dogs, weighing 23-27 kg, were divided into three groups. After laparotomy, the volume of the primary rectum was measured so that it could be compared with that of the neorectum at the end of the study. After rectal resection in Group A, the colon was directly anastomosed to the anus. In Group B, a 5-cm longitudinal incision was made 2 cm proximal to the anastomosis and was sutured transversely (coloplasty). In Group C, a 5-cm ileal J-pouch was interposed between the colon and anus. After 8 weeks, the neorectum was evaluated for volume, radiology, and pathology. Results: All the samples were alive until the end of the study. The healing of the anastomotic lines was acceptable (pathologically) in all. The mean volume expansion was 20.9% in Group A, 21.7% in Group B, and 118.2% in Group C, with the latter being significantly higher than that of the other groups (P=0.03). Colon J-pouch and coloplasty after proctectomy in some situations have not been performable. This study evaluated the performance of ileal J-pouch interposition. Conclusion: This study showed that ileal J-pouch interposition might produce an acceptable reservoir function and that it seems feasible and safe in selected cases. PMID:24644380

  14. Interposition of ileal j-pouch for rectum reconstruction in dog.

    Science.gov (United States)

    Ghahramani, Leila; Yazdani, Saeed; Derakhshani, Saeed; Rezaianzadeh, Abbas; Jalli, Reza; Geramizadeh, Bita; Safarpour, Ali Reza; Rahimikazerooni, Salar; Hosseini, Seyed Vahid

    2014-03-01

    The gold standard of the management of rectal cancer in the middle and lower parts is low anterior resection with coloanal anastomosis. About 50% of the patients undergoing this procedure might experience some complications because of the low capacity of the neorectum. The aim of this study was to evaluate ileal J-pouch interposition as a neorectum between the anal canal and the remaining colon in comparison to coloanal anastomosis and transverse coloplasty. Twelve dogs, weighing 23-27 kg, were divided into three groups. After laparotomy, the volume of the primary rectum was measured so that it could be compared with that of the neorectum at the end of the study. After rectal resection in Group A, the colon was directly anastomosed to the anus. In Group B, a 5-cm longitudinal incision was made 2 cm proximal to the anastomosis and was sutured transversely (coloplasty). In Group C, a 5-cm ileal J-pouch was interposed between the colon and anus. After 8 weeks, the neorectum was evaluated for volume, radiology, and pathology. All the samples were alive until the end of the study. The healing of the anastomotic lines was acceptable (pathologically) in all. The mean volume expansion was 20.9% in Group A, 21.7% in Group B, and 118.2% in Group C, with the latter being significantly higher than that of the other groups (P=0.03). Colon J-pouch and coloplasty after proctectomy in some situations have not been performable. This study evaluated the performance of ileal J-pouch interposition. This study showed that ileal J-pouch interposition might produce an acceptable reservoir function and that it seems feasible and safe in selected cases.

  15. [Reconstruction of the extensor pollicis longus tendon by transposition of the extensor indicis tendon].

    Science.gov (United States)

    Loos, A; Kalb, K; Van Schoonhoven, J; Landsleitner Dagger, B

    2003-12-01

    Rupture of the extensor pollicis longus-tendon (EPL) is a frequent complication after distal radius fractures. Other traumatic and non-traumatic reasons for this tendon lesion are known, including a theory about a disorder in the blood supply to the tendon itself. We examined 40 patients after reconstruction of the EPL-tendon in a mean follow-up time of 30 months. All patients were clinically examined and a DASH questionnaire was answered by all patients. The method to reconstruct the EPL-tendon was the transposition of the extensor indicis-tendon. After the operations the thumb was put in a splint for four weeks in a "hitch-hiker's-position". 31 ruptures of the tendon (77.5 %) were a result of trauma. In 20 of them (50 %) a distal radius fracture had occurred. Clinical examination included measurements of the movement of the thumb- and index-finger joints, the grip strength and the maximal span of the hand. Significant differences were not found. The isolated extension of the index finger was possible in all patients. But it was reduced in ten cases which represent 25 %. Our results were evaluated by the Geldmacher score to evaluate the reconstruction of the EPL-tendon. 20 % excellent, 65 % good, 12.5 % fair and 2.5 % poor results were reached. The Geldmacher score was used critically. We suggest its modification for the evaluation of thumb abduction. The DASH score reached a functional value of ten points which represents a very good result. In conclusion the extensor indicis-transposition is a safe method to reconstruct the EPL-tendon. Its substantial advantage is taking a healthy muscle as the motor, thereby avoiding the risk of using a degenerated muscle in late tendon reconstruction. A powerful extension of the index finger will be maintained by physical education. Generally, the loss of the extension of the index finger is negligible. It does not disturb the patients. But it has to be discussed with the patient before the operation.

  16. Dysphagia after Colon Interposition Graft for Esophageal Carcinoma

    Directory of Open Access Journals (Sweden)

    C. Spitali

    2012-01-01

    Full Text Available Colon interposition is an established technique for esophageal reconstruction. We describe the case of primary adenocarcinoma arising in a colonic interposition graft that was performed after total esophagectomy for recurrence adenocarcinoma derived from the Barrett esophagus.

  17. Pain level after ACL reconstruction: A comparative study between free quadriceps tendon and hamstring tendons autografts.

    Science.gov (United States)

    Buescu, Cristian Tudor; Onutu, Adela Hilda; Lucaciu, Dan Osvald; Todor, Adrian

    2017-03-01

    The objective of this study was to compare the pain levels and analgesic consumption after single bundle ACL reconstruction with free quadriceps tendon autograft versus hamstring tendon autograft. A total of 48 patients scheduled for anatomic single-bundle ACL reconstruction were randomized into two groups: the free quadriceps tendon autograft group (24 patients) and the hamstring tendons autograft group (24 patients). A basic multimodal analgesic postoperative program was used for all patients and rescue analgesia was provided with tramadol, at pain scores over 30 on the Visual Analog Scale. The time to the first rescue analgesic, the number of doses of tramadol and pain scores were recorded. The results within the same group were compared with the Wilcoxon signed test. Supplementary analgesic drug administration proved significantly higher in the group of subjects with hamstring grafts, with a median (interquartile range) of 1 (1.3) dose, compared to the group of subjects treated with a quadriceps graft, median = 0.5 (0.1.25) (p = 0.009). A significantly higher number of subjects with a quadriceps graft did not require any supplementary analgesic drug (50%) as compared with subjects with hamstring graft (13%; Z-statistics = 3.01, p = 0.002). The percentage of subjects who required a supplementary analgesic drug was 38% higher in the HT group compared with the FQT group. The use of the free quadriceps tendon autograft for ACL reconstruction leads to less pain and analgesic consumption in the immediate postoperative period compared with the use of hamstrings autograft. Level I Therapeutic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  18. Colon interposition

    International Nuclear Information System (INIS)

    Isolauri, J.; Tampere Univ. Central Hospital; Paakkala, T.; Arajaervi, P.; Markkula, H.

    1987-01-01

    Colon interposition was carried out in 12 patients with oesophageal carcinoma and on 38 patients with benign oesophageal disease an average of 71 months before the radiographic examination. Various ischaemic changes including 'jejunization', loss of haustration and stricture formation were observed in 15 cases. In 12 patients one or several diverticula were seen in the colon graft. Reflux was observed in 17 cases in supine position. Double contrast technique in the examination of interposed colon is recommended. (orig.)

  19. Long-term comparison of boomerang-shaped jejunal interposition and Billroth-I reconstruction after distal gastrectomy.

    Science.gov (United States)

    Sasaki, Kinro; Miyachi, Kazuhito; Yoda, Norihito; Onodera, Shinichi; Satomura, Hitoshi; Otsuka, Kichiro; Nakajima, Masanobu; Yamaguchi, Satoru; Sunagawa, Masakatsu; Kato, Hiroyuki

    2015-05-01

    Billroth-I (BI) is a simple, physiological method of reconstruction following distal gastrectomy. In actuality, postoperative QOL is by no means favorable due to the high incidence of post-gastrectomy syndrome. The aim of this study is to assess the safety and efficacy of boomerang-shaped jejunal interposition (BJI) after distal gastrectomy. Sixty-six patients with early gastric cancer underwent the BI procedure (n = 33) or BJI (n = 33) after distal gastrectomy, following which they were compared for 5 years. Tumor characteristics, operative details, postoperative complications and complaints, number of meals, and body weight were analyzed. Patients were followed up by endoscopy every 12 months. There were no significant differences in the incidence of postoperative complications. The incidence of heartburn (30 vs. 0 %, P = 0.0009) and oral bitterness (33 vs. 6 %, P = 0.0112) were significantly lower in the BJI cases. Endoscopic findings revealed significantly lower incidences of reflux esophagitis (24 vs. 0 %, P = 0.0051) and remnant gastritis (70 vs. 3 %, P < 0.0001) in the BJI group. The incidence of food stasis was low in both groups (12 vs. 15 %). In the BJI group, 30 patients (90 %) were eating 3 meals/day within 12 months, whereas in the BI group, 16 patients (48 %) were still eating 5 meals/day at 12 months or later. BJI is as safe as BI, but is better in terms of improvement in bile reflux and food intake without stasis. This procedure, therefore, appears to be a useful method for reconstruction after distal gastrectomy.

  20. Arthroscopic assisted tendon reconstruction for triangular fibrocartilage complex irreparable tears.

    Science.gov (United States)

    Luchetti, R; Atzei, A

    2017-05-01

    We report our 11-year experience of performing arthroscopically assisted triangular fibrocartilage complex reconstruction in the treatment of chronic distal radio-ulnar joint instability resulting from irreparable triangular fibrocartilage complex injuries. Eleven patients were treated. Three skin incisions were made in order to create radial and ulna tunnels for passage of the tendon graft, which is used to reconstruct the dorsal and palmar radio-ulnar ligaments, under fluoroscopic and arthroscopic guidance. At a mean follow-up of 68 months all but one had a stable distal radio-ulnar joint. Pain and grip strength, Mayo wrist score, Disability of the Arm Hand and Shoulder and patient-rated wrist and hand evaluation scores improved. The ranges of forearm rotation remained largely unchanged. Complications included an early tendon graft tear, two late-onset graft ruptures, one ulna styloid fracture during surgery and persistent wrist discomfort during forearm rotation requiring tendon graft revision in one case. An arthroscopic assisted approach for triangular fibrocartilage complex reconstruction appears safe and produces comparable results with the open technique. IV.

  1. Leiomyosarcoma of inferior vena cava involving bilateral renal veins: Surgical challenges and reconstruction with upfront saphenous vein interposition graft for left renal vein outflow

    Directory of Open Access Journals (Sweden)

    Rishi Nayyar

    2010-01-01

    Full Text Available Leiomyosarcoma of inferior vena cava (IVC involving bilateral renal veins presents a surgical challenge. Herein, we report the successful management of two such cases using restoration of left renal venous outflow by saphenous vein interposition graft as first step of surgery. Then radical resection of tumor and right kidney was done. IVC was lastly reconstructed using Gore-Tex graft. This report highlights the surgical challenges to ensure radical resection. Furthermore, the importance of restoring left renal outflow in presence of concomitant right nephrectomy is discussed. Both the patients were disease free at six months with no loss of left renal glomerular filtration rate.

  2. Reconstruction of medial patellofemoral ligament using quadriceps tendon combined with reconstruction of medial patellotibial ligament using patellar tendon: initial experience

    Directory of Open Access Journals (Sweden)

    Betina Bremer Hinckel

    2016-02-01

    Full Text Available ABSTRACT OBJECTIVE: To describe a surgical technique for anatomical reconstruction of the medial patellofemoral ligament using the quadriceps tendon, combined with reconstruction of the medial patellotibial ligament using the patellar tendon; and to present the initial results from a case series. METHOD: The proposed technique was used on a series of cases of patients with diagnoses of patellofemoral instability and indications for surgical treatment, who were attended by the Knee Group of HC-IOT, University of São Paulo. The following were evaluated before and after the operation: range of motion (ROM, apprehension test, lateral translation test, patellar inclination test, inverted J sign, subluxation upon extension, pain from compression of the patella and pain from contraction of the quadriceps. After the operation, the patients were asked whether any new episode of dislocation had occurred, what their degree of satisfaction with the surgery was (on a scale from 0 to 10 and whether they would be prepared to go through this operation again. RESULTS: Seven knees were operated, in seven patients, with a mean follow-up of 5.46 months (±2.07. Four patients who presented apprehension before the operation did not show this after the operation. The lateral translation test became normal for all the patients, while the patellar inclination test remained positive for two patients. The patients with an inverted J sign continued to be positive for this sign. Five patients were positive for subluxation upon extension before the operation, but all patients were negative for this after the operation. None of the patients presented any new episode of dislocation of the patella. All of them stated that they were satisfied: five gave a satisfaction score of 9 and two, a score of 10. All of them said that they would undergo the operation again. Only one patient presented a postoperative complication: dehiscence of the wound. CONCLUSION: Reconstruction of the

  3. An Isolated Medial Patellofemoral Ligament Reconstruction with Patellar Tendon Autograft

    Directory of Open Access Journals (Sweden)

    Dariusz Witoński

    2013-01-01

    Full Text Available The aim of the study was to evaluate the results of the medial patellofemoral ligament reconstruction with a medial strip of patellar tendon autograft after a minimum 2-year followup. Ten patients (10 knees were operated on by one surgeon, according to the modified technique, described by Camanho, without any bone plug at free graft end. The mean age of the patients was 27.2 years (ranging from 18 to 42 years. The mean follow-up period was 3 years and 7 months. All patients were reviewed prospectively. At the last follow-up visit, all the patients demonstrated a significant improvement in terms of patellofemoral joint stability, all aspects of the KOOS questionnaire, and Kujala et al.’s score (59.7 points preoperatively and 84.4 points at the last followup. No patient revealed recurrent dislocation. The SF-36 score revealed a significant improvement in bodily pain, general health, physical role functioning, social role functioning, and physical functioning domains. The described MPFL reconstruction with the use of the medial 1/3rd of patella tendon is an effective procedure that gives satisfactorily patellofemoral joint functions, improves the quality of life, and provides much pain relief. It is relatively simple, surgically not extensive, and economically cost-effective procedure.

  4. Estudo comparativo entre ressecção do trapézio e interposição tendinosa com e sem ligamentoplastia no tratamento da artrose carpometacarpiana do polegar Comparative study between trapezium resection and tendon interposition with and without ligament plasty in the management of carpometacarpal arthrosis of the thumb

    Directory of Open Access Journals (Sweden)

    Arlindo Gomes Pardini Junior

    2008-03-01

    opponency, movements of the metacarpophalangeal joint, pinching and pressure strength, radiographic measurement of the distance between the first metacarpian and the scaphoid, and measurement of the angle between the first and the second metacarpian. Subjective evaluation was done with a DASH questionnaire, an analogical-digital scale to evaluate pain and patient satisfaction. RESULTS AND CONCLUSION: After application of the criteria described and using Student t test for statistical analysis, the authors concluded that the ligament reconstruction has no advantage over the simple tendon interposition in carpometacarpal arthrosis of the thumb.

  5. [Reconstruction of chronic Achilles tendon rupture with flexor hallucis longus tendon harvested using a minimally invasive technique].

    Science.gov (United States)

    Miao, Xudong; Wu, Yongping; Tao, Huimin; Yang, Disheng

    2011-07-01

    To evaluate the effectiveness of flexor hallucis longus tendon harvested using a minimally invasive technique in reconstruction of chronic Achilles tendon rupture. Between July 2006 and December 2009, 22 patients (22 feet) with chronic Achilles tendon rupture were treated, including 16 males and 6 females with a median age of 48 years (range, 28-65 years). The disease duration was 27-1,025 days (median, 51 days). Twenty-one patients had hooflike movement's history and 1 patient had no obvious inducement. The result of Thompson test was positive in 22 cases. The score was 53.04 +/- 6.75 according to American Orthopedic Foot and Ankle Society (AOFAS) ankle and hindfoot score system. MRI indicated that the gap of the chronic Achilles tendon rupture was 4.2-8.0 cm. A 3 cm-long incision was made vertically in the plantar aspect of the midfoot and a 1 cm-long transverse incision was made in a plantar flexor crease at the base of the great toe to harvest flexor hallucis longus tendon. The flexor hallucis longus tendon was 10.5-13.5 cm longer from tuber calcanei to the end of the Achilles tendon, and then the tendon was fixed to the tuber calcanei using interface screws or anchor nail after they were woven to form reflexed 3-bundle and sutured. Wound healed by first intention in all patients and no early complication occurred. Twenty-two patients were followed up 12-42 months (mean, 16.7 months). At 12 months after operation, The AOFAS ankle and hindfoot score was 92.98 +/- 5.72, showing significant difference when compared with that before operation (t= -40.903, P=0.000). The results were excellent in 18 cases, good in 2 cases, and fair in 2 cases with an excellent and good rate of 90.9%. No sural nerve injury, posterior tibial nerve injury, plantar painful scar, medial plantar nerve injury, and lateral plantar nerve injury occurred. Chronic Achilles tendon rupture reconstruction with flexor hallucis longus tendon harvested using a minimally invasive technique offers a

  6. Interposition vein cuffs.

    Science.gov (United States)

    Harris, P; Da Silva, T; How, T

    1996-01-01

    A vein cuff interposed at the distal anastomosis between a prosthetic vascular graft and a recipient infrageniculate artery improves the chances of continued patency of the graft, at least in the short and medium term. The mode of effect appears to be suppression or modification of anastomotic myointimal hyperplasia (MIH). In the event of graft failure the recipient artery and run-off vessels remain free from MIH and their patency is preserved thereby improving the prospects for further vascular reconstruction and limb salvage. The mechanisms by which interposition vein cuffs might modulate MIH are reviewed. Experimental evidence is described to show that the geometry of a cuffed anastomosis promotes a characteristic haemodynamic flow structure with a stable vortex. It is suggested that this vortex exerts greater shear stress upon the wall of the artery than the normal laminar flow observed in conventional anastomoses. High shear stress is known to inhibit MIH.

  7. Knee extension and flexion muscle power after anterior cruciate ligament reconstruction with patellar tendon graft or hamstring tendons graft: a cross-sectional comparison 3 years post surgery

    DEFF Research Database (Denmark)

    Ageberg, Eva; Roos, Harald; Silbernagel, Karin

    2008-01-01

    Hamstring muscles play a major role in knee-joint stabilization after anterior cruciate ligament (ACL) injury. Weakness of the knee extensors after ACL reconstruction with patellar tendon (PT) graft, and in the knee flexors after reconstruction with hamstring tendons (HT) graft has been observed ...

  8. Free Bone Plug Quadriceps Tendon Harvest and Suspensory Button Attachment for Anterior Cruciate Ligament Reconstruction.

    Science.gov (United States)

    Todor, Adrian; Caterev, Sergiu; Nistor, Dan Viorel; Khallouki, Youssef

    2016-06-01

    The most commonly used autografts for anterior cruciate ligament reconstruction are the bone-patellar tendon-bone and hamstring tendons. Each has its advantages and limitations. The bone-patellar tendon-bone autograft can lead to more donor-site morbidity, and the hamstring autograft can be unpredictable in size. The quadriceps tendon, with or without a bone block, has been described as an alternative graft source and has been used especially in revision cases, but in recent years, it has attracted attention even for primary cases. We report a technique for harvesting a free bone quadriceps tendon graft and attaching an extracortical button for femoral fixation for anterior cruciate ligament reconstruction.

  9. Quadriceps tendon autograft for arthroscopic knee ligament reconstruction: use it now, use it often.

    Science.gov (United States)

    Sheean, Andrew J; Musahl, Volker; Slone, Harris S; Xerogeanes, John W; Milinkovic, Danko; Fink, Christian; Hoser, Christian

    2018-04-28

    Traditional bone-patellar tendon-bone and hamstring tendon ACL grafts are not without limitations. A growing body of anatomic, biomechanical and clinical data has demonstrated the utility of quadriceps tendon autograft in arthroscopic knee ligament reconstruction. The quadriceps tendon autograft provides a robust volume of tissue that can be reliably harvested, mitigating the likelihood of variably sized grafts and obviating the necessity of allograft augmentation. Modern, minimally invasive harvest techniques offer the advantages of low rates of donor site morbidity and residual extensor mechanism strength deficits. New data suggest that quadriceps tendon autograft may possess superior biomechanical characteristics when compared with bone-patella tendon-bone (BPTB) autograft. However, there have been very few direct, prospective comparisons between the clinical outcomes associated with quadriceps tendon autograft and other autograft options (eg, hamstring tendon and bone-patellar tendon-bone). Nevertheless, quadriceps tendon autograft should be one of the primary options in any knee surgeon's armamentarium. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Reconstruction of Ligament and Tendon Defects Using Cell Technologies.

    Science.gov (United States)

    Chailakhyan, R K; Shekhter, A B; Ivannikov, S V; Tel'pukhov, V I; Suslin, D S; Gerasimov, Yu V; Tonenkov, A M; Grosheva, A G; Panyushkin, P V; Moskvina, I L; Vorob'eva, N N; Bagratashvili, V N

    2017-02-01

    We studied the possibility of restoring the integrity of the Achilles tendon in rabbits using autologous multipotent stromal cells. Collagen or gelatin sponges populated with cells were placed in a resorbable Vicryl mesh tube and this tissue-engineered construct was introduced into a defect of the middle part of the Achilles tendon. In 4 months, histological analysis showed complete regeneration of the tendon with the formation of parallel collagen fibers, spindle-shaped tenocytes, and newly formed vessels.

  11. Acromioclavicular Reconstruction using Autogenous Semitendinosus Tendon Graft and the Importance of Postoperative Rehabilitation: A Case Report

    Directory of Open Access Journals (Sweden)

    Jade PY Ho

    2013-11-01

    Full Text Available We present a case of chronic acromioclavicular joint dislocation (Rockwood type 5 in which the choice of acromioclavicular reconstruction using autogenous semitendinosus tendon graft was made due to its superiority in anatomical reconstruction of the coracoclavicular ligaments, and the impact of postoperative rehabilitation on the recovery of this patient. We also discuss the rationale behind this.

  12. Simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft.

    Science.gov (United States)

    Shin, Sang-Jin; Campbell, Sean; Scott, Jonathan; McGarry, Michelle H; Lee, Thay Q

    2014-09-01

    The purpose of this study was to introduce a novel surgical technique for simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft and to compare its biomechanical characteristics to those of a coracoid cerclage reconstruction of the coracoclavicular ligaments. Six matched pairs of human acromioclavicular joints with an average age of 54.8 ± 7.8 years were used. One shoulder from each pair received the single tendon acromioclavicular-coracoclavicular reconstruction; the contralateral shoulder received the coracoid cerclage reconstruction. Bovine extensor tendon was used for both techniques. The single tendon acromioclavicular-coracoclavicular reconstruction technique provided anatomic restoration of the two coracoclavicular ligaments and the superior and inferior acromioclavicular ligaments simultaneously using one coracoid hole, one acromion hole, and two clavicular holes with interference screws. Anterior-posterior and superior-inferior translations were quantified for all specimens before and after reconstruction, followed by load to failure testing. Following coracoid cerclage reconstruction, total anterior-posterior translation was significantly greater than intact (10.0 ± 5.7 mm; p = 0.008). Following single tendon acromioclavicular-coracoclavicular reconstruction, there was no significant difference in anterior-posterior translation compared to intact (-1.6 ± 2.2 mm; n.s.). The coracoid cerclage technique demonstrated significantly greater anterior-posterior translation than the single tendon acromioclavicular-coracoclavicular technique (p = 0.007). Both techniques restored superior-inferior translation to the intact condition (n.s.). Ultimate load, deformation at ultimate load, and energy absorbed at ultimate load were significantly greater after acromioclavicular-coracoclavicular reconstruction than after coracoid cerclage reconstruction (p

  13. Anatomic single-bundle anterior cruciate ligament reconstruction improves walking economy: hamstrings tendon versus patellar tendon grafts.

    Science.gov (United States)

    Iliopoulos, Efthymios; Galanis, Nikiforos; Zafeiridis, Andreas; Iosifidis, Michael; Papadopoulos, Pericles; Potoupnis, Michael; Geladas, Nikolaos; Vrabas, Ioannis S; Kirkos, John

    2017-10-01

    Anterior cruciate ligament (ACL) injury is associated with a pathologic gait pattern and increased energy cost during locomotion. ACL reconstruction could improve the gait pattern. Hamstrings tendon (HAM) and bone-patellar tendon-bone (BPTB) grafts are usually used for reconstruction. The aim of this study was to compare the efficacy of anatomic ACL reconstruction with HAM and BPTB grafts on improving and normalizing the energy cost and physiologic reserves during flat, uphill, and downhill walking. Twenty male subjects with unilateral ACL injuries were randomly assigned to ACL reconstruction with a HAM (n = 10) or BPTB (n = 10) graft. Ten matched controls were also enrolled. All participants performed three 8-min walking tasks at 0, +10, and -10 % gradients before and 9 months after surgery. Energy cost (oxygen consumption, VO 2 ), heart rate (HR), and ventilation (VE) were measured. Lysholm/IKDC scores were recorded. Pre-operatively, VO 2 , HR, and VE were higher in the HAM and BPTB groups than in controls during walking at 0, +10, and -10 % gradients (p energy cost and nearly normalized locomotion economy and cardiorespiratory reserves during flat, uphill, and downhill walking. The improved locomotion economy is an additional benefit of anatomic ACL reconstruction, irrespective of the type of graft used, that the orthopaedic surgeons should consider. II.

  14. Reconstruction of long digital extensor tendon by cranial tibial muscle fascia graft in a dog.

    Science.gov (United States)

    Sabiza, Soroush; Khajeh, Ahmad; Naddaf, Hadi

    2016-01-01

    Tendon rupture in dogs is generally the result of a direct trauma. This report described the use of adjacent muscle autogenic fascial graft for reconstruction of distal rupture of long digital extensor tendon in a dog. A two-year-old male mix breed dog, was presented with a non-weight bearing lameness of the right hind limb and a deep rupture of lateral side of right tarsus. History taking revealed that this rupture appeared without any apparent cause, when walking around the farm, three days before. Radiography was done and no fracture was observed. Hyperextension of right tarsal joint compared to left limb was observed. Under general anesthesia, after dissections of the ruptured area, complete rupture of long digital extensor tendon was revealed. Then, we attempted to locate the edge of the tendon, however, the tendon length was shortened approximately 1 cm. Hence, a strip of 1 cm length from fascia of cranial tibial muscle was harvested to fill the defect. The graft was sutured to the two ends of tendon using locking loop pattern. Subcutaneous layers and the skin were sutured routinely. Ehmer sling bandage was applied to prevent weight bearing on the surgical region. Re-examination and phone contact with the owner eight weeks and six months postoperatively revealed a poor lameness and excellent function of the dog, respectively. It could be concluded that the fascia of adjacent muscles can be used as an autogenic graft for reconstruction of some tendon ruptures.

  15. Acromioclavicular joint reconstruction using a tendon graft: a biomechanical study comparing a novel “sutured throughout” tendon graft to a standard tendon graft

    Directory of Open Access Journals (Sweden)

    Naziri Qais

    2016-01-01

    Full Text Available Background: With a recurrence rate of over 30%, techniques that offer stronger acromioclavicular (AC joint reconstruction through increased graft strength may provide longevity. The purpose of our study was to determine the biomechanical strength of a novel tendon graft sutured throughout compared to a native tendon graft in Grade 3 anatomical AC joint reconstruction. Methods: For this in vitro experiment, nine paired (n = 18 embalmed cadaveric AC joints of three males and six females (age 86 years, range 51–94 years were harvested. Anatomic repair with fresh bovine Achilles tendon grafts without bone block was simulated. Specimens were divided into two groups; with group 1 using grafts with ultra-high molecular-weight polyethylene (UHMWPE suture ran throughout the entire length. In group 2, reconstruction with only native allografts was performed. The distal scapula and humerus were casted in epoxy compound and mounted on the mechanical testing machine. Tensile tests were performed using a mechanical testing machine at the rate of 50 mm/min. Maximum load and displacement to failure were collected. Results: The average load to failure was significantly higher for group 1 compared to group 2, with mean values of 437.5 N ± 160.7 N and 94.4 N ± 43.6 N, (p = 0.001. The average displacement to failure was not significantly different, with 29.7 mm ± 10.6 mm in group 1 and 25 mm ± 9.1 mm in group 2 (p = 0.25. Conclusion: We conclude that a UHMWPE suture reinforced graft can provide a 3.6 times stronger AC joint reconstruction compared to a native graft.

  16. [Isokinetic assessment with two years follow-up of anterior cruciate ligament reconstruction with patellar tendon or hamstring tendons].

    Science.gov (United States)

    Condouret, J; Cohn, J; Ferret, J-M; Lemonsu, A; Vasconcelos, W; Dejour, D; Potel, J-F

    2008-12-01

    This retrospective multicentric study was designed to assess the outcome of quadriceps and hamstrings muscles two years after Anterior Cruciate Ligament (ACL) reconstruction and compare muscles recovery depending on the type of graft and individual variables like age, gender, level of sport, but also in terms of discomfort, pain and functional score. The results focused on the subjective and objective IKDC scores, SF36, the existence or not of subjective disorders and their location. The review included isokinetic muscle tests concentric and eccentric extensors/flexors but also internal rotators/external rotators with analysis of mean work and mean power. One hundred and twenty-seven patients were included with an average age 29 years (+/-10). They all had an ACL reconstruction with patellar tendon or hamstring tendon with single or double bundles. In the serie, the average muscles deficit at two years was 10% for the flexors and extensors but with a significant dispersion. Significant differences were not noted in the mean values of all parameters in term of sex or age (over 30 years or not), neither the type of sport, nor of clinical assessment (Class A and B of objective IKDC score), nor the existence of anterior knee pain. There was a relationship between the level of extensor or flexor recovery and the quality of functional results with minimal muscle deficits close to 5% if the IKDC score was over 90 and deficits falling to 15% in the group with IKDC score less than 90. The type of reconstruction (patellar tendon versus hamstrings) had an influence on the muscle deficit. For extensors, the recovery was the same in the two groups, more than 90% at two years and the distribution of these two populations by level of deficit was quite the same. For flexors, residual deficits were significantly higher in the hamstrings group on the three studied parameters whatever the speed and the type of contraction (concentric or eccentric) with an average deficit of 14 to 18

  17. Biology and augmentation of tendon-bone insertion repair

    Directory of Open Access Journals (Sweden)

    Lui PPY

    2010-08-01

    Full Text Available Abstract Surgical reattachment of tendon and bone such as in rotator cuff repair, patellar-patella tendon repair and anterior cruciate ligament (ACL reconstruction often fails due to the failure of regeneration of the specialized tissue ("enthesis" which connects tendon to bone. Tendon-to-bone healing taking place between inhomogenous tissues is a slow process compared to healing within homogenous tissue, such as tendon to tendon or bone to bone healing. Therefore special attention must be paid to augment tendon to bone insertion (TBI healing. Apart from surgical fixation, biological and biophysical interventions have been studied aiming at regeneration of TBI healing complex, especially the regeneration of interpositioned fibrocartilage and new bone at the healing junction. This paper described the biology and the factors influencing TBI healing using patella-patellar tendon (PPT healing and tendon graft to bone tunnel healing in ACL reconstruction as examples. Recent development in the improvement of TBI healing and directions for future studies were also reviewed and discussed.

  18. Anterior Cruciate Ligament Reconstruction using Bone Patellar Tendon Bone autograft in ACL deficient Knee

    Directory of Open Access Journals (Sweden)

    Navin Kumar Karn

    2015-12-01

    Full Text Available Background & Objectives: Injury to Anterior Cruciate Ligament (ACL reconstruction has increased because of increased interest in sports. There are various grafts used for reconstruction of ACL, for example, Bone Patellar Tendon Bone, Hamstring etc. The study was conducted to evaluate the results of Bone Patellar Tendon Bone graft used for reconstruction of Anterior Cruciate Ligament.Materials & Methods: 40 patients with chronic ACL deficient knee presenting to Neuro Hospital from July 2011 to June 2013 were included in the study. The patients with intraarticular fracture of knee, severe OA knee, local active or suspected infection and systemic disease that might influence the study results were excluded from the study. Bone patellar tendon bone graft was harvested from ipsilateral knee in all the cases. The patient was followed till 2 year with specified programme of rehabilitation. The pain was assessed using VAS and the function of the knee was assessed using Modified WOMAC knee index.Results: The long term satisfactory results in terms of functional stability, symptom relief and return to preinjury level of activity was seen in 32 cases (80%. Two knees got infected out of which one required arthroscopic debridement. Mean visual analogue scale was 8 and modified WOMAC knee score was 3 at 2 year follow up.Conclusion: Bone patellar tendon bone graft is useful in high demand patients and cost effective option with high patient satisfaction rate for reconstruction of ACL.JCMS Nepal. 2015;11(3:12-15.

  19. A Modified Method for Reconstruction of Chronic Rupture of the Quadriceps Tendon after Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    S Singh

    2008-11-01

    Full Text Available We describe herein a modified technique for reconstruction of chronic rupture of the quadriceps tendon in a patient with bilateral total knee replacement and distal realignment of the patella. The surgery involved the application of a Dacron graft and the ‘double eights’ technique. The patient achieved satisfactory results after surgery and we believe that this technique of reconstruction offers advantages over other methods.

  20. Mechanical Loading Improves Tendon-Bone Healing in a Rabbit Anterior Cruciate Ligament Reconstruction Model by Promoting Proliferation and Matrix Formation of Mesenchymal Stem Cells and Tendon Cells

    Directory of Open Access Journals (Sweden)

    Fanglong Song

    2017-02-01

    Full Text Available Background/Aims: This study investigated the effect of mechanical stress on tendon-bone healing in a rabbit anterior cruciate ligament (ACL reconstruction model as well as cell proliferation and matrix formation in co-culture of bone-marrow mesenchymal stem cells (BMSCs and tendon cells (TCs. Methods: The effect of continuous passive motion (CPM therapy on tendon-bone healing in a rabbit ACL reconstruction model was evaluated by histological analysis, biomechanical testing and gene expressions at the tendon-bone interface. Furthermore, the effect of mechanical stretch on cell proliferation and matrix synthesis in BMSC/TC co-culture was also examined. Results: Postoperative CPM therapy significantly enhanced tendon-bone healing, as evidenced by increased amount of fibrocartilage, elevated ultimate load to failure levels, and up-regulated gene expressions of Collagen I, alkaline phosphatase, osteopontin, Tenascin C and tenomodulin at the tendon-bone junction. In addition, BMSC/TC co-culture treated with mechanical stretch showed a higher rate of cell proliferation and enhanced expressions of Collagen I, Collagen III, alkaline phosphatase, osteopontin, Tenascin C and tenomodulin than that of controls. Conclusion: These results demonstrated that proliferation and differentiation of local precursor cells could be enhanced by mechanical stimulation, which results in enhanced regenerative potential of BMSCs and TCs in tendon-bone healing.

  1. [Arthroscopic double-row reconstruction of high-grade subscapularis tendon tears].

    Science.gov (United States)

    Plachel, F; Pauly, S; Moroder, P; Scheibel, M

    2018-04-01

    Reconstruction of tendon integrity to maintain glenohumeral joint centration and hence to restore shoulder functional range of motion and to reduce pain. Isolated or combined full-thickness subscapularis tendon tears (≥upper two-thirds of the tendon) without both substantial soft tissue degeneration and cranialization of the humeral head. Chronic tears of the subscapularis tendon with higher grade muscle atrophy, fatty infiltration, and static decentration of the humeral head. After arthroscopic three-sided subscapularis tendon release, two double-loaded suture anchors are placed medially to the humeral footprint. Next to the suture passage, the suture limbs are tied and secured laterally with up to two knotless anchors creating a transosseous-equivalent repair. The affected arm is placed in a shoulder brace with 20° of abduction and slight internal rotation for 6 weeks postoperatively. Rehabilitation protocol including progressive physical therapy from a maximum protection phase to a minimum protection phase is required. Overhead activities are permitted after 6 months. While previous studies have demonstrated superior biomechanical properties and clinical results after double-row compared to single-row and transosseous fixation techniques, further mid- to long-term clinical investigations are needed to confirm these findings.

  2. Occult Interpositional Rotator Cuff - an Extremely Rare Case of Traumatic Rotator Cuff Tear

    Energy Technology Data Exchange (ETDEWEB)

    Su, Wei Ren; Jou, I Ming [National Cheng Kung University Hospital, Tainan (China); Lin, Cheng Li [Show-Chwan Memorial Hospital, Changhua (China); Chih, Wei Hsing [Chia-Yi Christian Hospital, Chiayi (China)

    2012-01-15

    Traumatic interposition of a rotator cuff tendon in the glenohumeral joint without recognizable glenohumeral dislocation is an unusual complication after shoulder trauma. Here we report the clinical and imaging presentations of a 17-year-old man with trapped rotator cuff tendons in the glenohumeral joint after a bicycle accident. The possible trauma mechanism is also discussed.

  3. Hydroxyapatite-doped polycaprolactone nanofiber membrane improves tendon-bone interface healing for anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Han, Fei; Zhang, Peng; Sun, Yaying; Lin, Chao; Zhao, Peng; Chen, Jiwu

    2015-01-01

    Hamstring tendon autograft is a routine graft for anterior cruciate ligament (ACL) reconstruction. However, ways of improving the healing between the tendon and bone is often overlooked in clinical practice. This issue can be addressed by using a biomimetic scaffold. Herein, a biomimetic nanofiber membrane of polycaprolactone/nanohydroxyapatite/collagen (PCL/nHAp/Col) is fabricated that mimics the composition of native bone tissue for promoting tendon-bone healing. This membrane has good cytocompatibility, allowing for osteoblast cell adhesion and growth and bone formation. As a result, MC3T3 cells reveal a higher mineralization level in PCL/nHAp/Col membrane compared with PCL membrane alone. Further in vivo studies in ACL reconstruction in a rabbit model shows that PCL/nHAp/Col-wrapped tendon may afford superior tissue integration to nonwrapped tendon in the interface between the tendon and host bone as well as improved mechanical strength. This study shows that PCL/nHAp/Col nanofiber membrane wrapping of autologous tendon is effective for improving tendon healing with host bone in ACL reconstruction.

  4. Anatomical Footprint of the Tibialis Anterior Tendon: Surgical Implications for Foot and Ankle Reconstructions

    Directory of Open Access Journals (Sweden)

    Madeleine Willegger

    2017-01-01

    Full Text Available This study aimed to analyze precisely the dimensions, shapes, and variations of the insertional footprints of the tibialis anterior tendon (TAT at the medial cuneiform (MC and first metatarsal (MT1 base. Forty-one formalin-fixed human cadaveric specimens were dissected. After preparation of the TAT footprint, standardized photographs were made and the following parameters were evaluated: the footprint length, width, area of insertion, dorsoplantar location, shape, and additional tendon slips. Twenty feet (48.8% showed an equal insertion at the MC and MT1, another 20 feet (48.8% had a wide insertion at the MC and a narrow insertion at the MT1, and 1 foot (2.4% demonstrated a narrow insertion at the MC and a wide insertion at the MT1. Additional tendon slips inserting at the metatarsal shaft were found in two feet (4.8%. Regarding the dorsoplantar orientation, the footprints were located medial in 29 feet (70.7% and medioplantar in 12 feet (29.3%. The most common shape at the MT1 base was the crescent type (75.6% and the oval type at the MC (58.5%. The present study provided more detailed data on the dimensions and morphologic types of the tibialis anterior tendon footprint. The established anatomical data may allow for a safer surgical preparation and a more anatomical reconstruction.

  5. Firm anchoring between a calcium phosphate-hybridized tendon and bone for anterior cruciate ligament reconstruction in a goat model

    Energy Technology Data Exchange (ETDEWEB)

    Mutsuzaki, Hirotaka [Department of Orthopaedic Surgery, Ibaraki Prefectural University of Health Sciences, 4669-2 Ami Ami-machi, Inashiki-gun, Ibaraki 300-0394 (Japan); Sakane, Masataka; Ochiai, Naoyuki [Department of Orthopaedic Surgery, Institute of Clinical Medicine, Graduate School of Comprehensive Human Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 (Japan); Hattori, Shinya; Kobayashi, Hisatoshi, E-mail: sakane-m@md.tsukuba.ac.j [Biomaterial Center, National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan)

    2009-08-15

    Using an alternative soaking process improved the tendon-bone attachment for a calcium phosphate (CaP)-hybridized tendon graft. We characterized the deposited CaP on and in tendons and analyzed the histology and mechanical properties of the tendon-bone interface in anterior cruciate ligament (ACL) reconstruction in goats. The tendon grafts to be implanted were soaked ten times alternately in a Ca-containing solution and a PO{sub 4}-containing solution for 30 s each. Needlelike CaP nanocrystals including low-crystalline apatite were deposited on and between collagen fibrils from the surface to a depth of 200{mu}m inside the tendon. The structure resembles the extracellular matrix of bone. In animal experiments, the CaP-hybridized tendon directly bonded with newly formed bone at 6 weeks (n = 3), while fibrous bonding was observed in the control (n = 3). The ultimate failure load was not statistically different between the CaP (n = 7) and control (n = 7). However, in the failure mode, all the tendon-bone interfaces were intact in the CaP group, while three of seven specimens were pulled out from bone tunnels in the control. The result suggested that the strength of the tendon-bone interface in the CaP group is superior to that in the control group. Clinically, firm tendon-bone anchoring may lead to good results without the knee instability associated with the loosening of the bone-tendon junction in ACL reconstruction.

  6. Quadriceps Tendon Autograft in Anterior Cruciate Ligament Reconstruction: A Systematic Review.

    Science.gov (United States)

    Hurley, Eoghan T; Calvo-Gurry, Manuel; Withers, Dan; Farrington, Shane K; Moran, Ray; Moran, Cathal J

    2018-05-01

    To systematically review the current evidence to ascertain whether quadriceps tendon autograft (QT) is a viable option in anterior cruciate ligament reconstruction. A literature review was conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Cohort studies comparing QT with bone-patellar tendon-bone autograft (BPTB) or hamstring tendon autograft (HT) were included. Clinical outcomes were compared, with all statistical analyses performed using IBM SPSS Statistics for Windows, version 22.0, with P < .05 being considered statistically significant. We identified 15 clinical trials with 1,910 patients. In all included studies, QT resulted in lower rates of anterior knee pain than BPTB. There was no difference in the rate of graft rupture between QT and BPTB or HT in any of the studies reporting this. One study found that QT resulted in greater knee stability than BPTB, and another study found increased stability compared with HT. One study found that QT resulted in improved functional outcomes compared with BPTB, and another found improved outcomes compared with HT, but one study found worse outcomes compared with BPTB. Current literature suggests QT is a viable option in anterior cruciate ligament reconstruction, with published literature showing comparable knee stability, functional outcomes, donor-site morbidity, and rerupture rates compared with BPTB and HT. Level III, systematic review of Level I, II, and III studies. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  7. A Canine Arthroscopic Anterior Cruciate Ligament Reconstruction Model for Study of Synthetic Augmentation of Tendon Allografts.

    Science.gov (United States)

    Cook, James L; Smith, Pat; Stannard, James P; Pfeiffer, Ferris; Kuroki, Keiichi; Bozynski, Chantelle C; Cook, Cristi

    2017-09-01

    Novel graft types, fixation methods, and means for augmenting anterior cruciate ligament (ACL) reconstructions require preclinical validation prior to safe and effective clinical application. The objective of this study was to describe and validate a translational canine model for all-inside arthroscopic complete ACL reconstruction using a quadriceps tendon allograft with internal brace (QTIB). With institutional approval, adult research hounds underwent complete transection of the native ACL followed by all-inside ACL reconstruction using the novel QTIB construct with suspensory fixation ( n  = 10). Contralateral knees were used as nonoperated controls ( n  = 10). Dogs were assessed over a 6-month period using functional, diagnostic imaging, gross, biomechanical, and histologic outcome measures required for preclinical animal models. Study results suggest that the novel QTIB construct used for complete ACL reconstruction can provide sustained knee stability and function without the development of premature osteoarthritis in a rigorous and valid preclinical model. The unique configuration of the QTIB construct-the combination of a tendon allograft with a synthetic suture tape internal brace-allowed for an effective biologic-synthetic load-sharing ACL construct. It prevented early failure, allowed for direct, four-zone graft-to-bone healing, and functional graft remodeling while avoiding problems noted with use of all-synthetic grafts. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  8. A RETROSPECTIVE ANALYSIS OF ARTHROSCOPIC ACL RECONSTRUCTION WITH HAMSTRING TENDON GRAFT

    Directory of Open Access Journals (Sweden)

    Ashish R. Agarwal

    2017-08-01

    Full Text Available BACKGROUND ACL reconstruction is one of the commonest knee surgeries done. Young adults are the commonest patients; thus, this injury has a large impact on socioeconomic status of the family. The aim of the study is to study the outcome of arthroscopic ACL reconstruction with hamstring tendon graft. MATERIALS AND METHODS 50 patients following up in the OPD who had undergone ACL reconstruction with hamstring tendon graft are evaluated. Patients who had other lesions, such meniscal injuries or collateral injuries were discarded. These patients were evaluated by using Tegner and Lysholm score of 6 months, 12 months and 24 months. Settings- It is a retrospective analysis of the data collected from the patients who were opiated at Nair Hospital. RESULTS 90% of patients in the study were males. Mean age of the study population is 30.7 years. All the patients in the study had instability as a symptom, while 80% of them also had pain. Six months after surgery, according to Tegner and Lysholm score, 52% patients had good outcome, while 48% had fair outcome. At 2 years, 98% of study population had excellent outcome. CONCLUSION Arthroscopic ACL reconstruction with hamstring graft is an effective way of treating ACL tear.

  9. The use of hamstring tendon graft for the anterior cruciate ligament reconstruction (benefi ts, problems and their solutions

    Directory of Open Access Journals (Sweden)

    V. V. Slastinin

    2017-01-01

    Full Text Available The search for optimal graft for anterior cruciate ligament reconstruction is going on. The donor site morbidity remains one of the major problems when using autografts. The article provides an overview of the advantages and disadvantages of using the hamstring tendon autografts for anterior cruciate ligament reconstruction, and the ways of solving the problems associated with using such types of grafts.

  10. Press-fit Femoral Fixation in ACL Reconstruction using Bone-Patellar Tendon-Bone Graft

    Directory of Open Access Journals (Sweden)

    Kaseb Mohammad Hasan

    2009-05-01

    Full Text Available Bone-patellar tendon auto graft is probably the most widely used graft for ACL reconstruction. Several methods for graft fixation have been described. To avoid intra-articular hardware we adopt biological fixation with a femoral trapezoidal press-fit fixation. A prospective study was performed on 30 consecutive active people who underwent ACL reconstruction with this technique by two surgeons between september2004 and march2007 (mean follow-up 15.2 months. Results were evaluated by an independent examiner using radiography, subjective and objective evaluation. Assessment using the IKDC knee scoring revealed 92% of the patients with a normal or nearly normal knee joint. Lysholm's score was 63.6(40- 86 preoperatively and 91.88(73-100 at the latest follow up (P < 0.005. No patient complained of instability at latest follow up. The quadriceps muscle showed mild atrophy at 3 and 6 months and at final follow-up. Five Patients complained of anterior knee pain and had a positive kneeling test. We found no graft displacement on follow up radiographs. All cases showed radiological evidence of graft osteointegration at last follow up. Our results show that press-fit fixation of trapezoidal bone graft in femoral tunnel is a simple, reliable, and cost-effective alternative for ACL recon-struction using bone-patellar tendon-bone graft.

  11. Biomechanical Effects of Acromioplasty on Superior Capsule Reconstruction for Irreparable Supraspinatus Tendon Tears.

    Science.gov (United States)

    Mihata, Teruhisa; McGarry, Michelle H; Kahn, Timothy; Goldberg, Iliya; Neo, Masashi; Lee, Thay Q

    2016-01-01

    Acromioplasty is increasingly being performed for both reparable and irreparable rotator cuff tears. However, acromioplasty may destroy the coracoacromial arch, including the coracoacromial ligament, consequently causing a deterioration in superior stability even after superior capsule reconstruction. The purpose of this study was to investigate the effects of acromioplasty on shoulder biomechanics after superior capsule reconstruction for irreparable supraspinatus tendon tears. The hypothesis was that acromioplasty with superior capsule reconstruction would decrease the area of subacromial impingement without increasing superior translation and subacromial contact pressure. Controlled laboratory study. Seven fresh-frozen cadaveric shoulders were evaluated using a custom shoulder testing system. Glenohumeral superior translation, the location of the humeral head relative to the glenoid, and subacromial contact pressure and area were compared among 4 conditions: (1) intact shoulder, (2) irreparable supraspinatus tendon tear, (3) superior capsule reconstruction without acromioplasty, and (4) superior capsule reconstruction with acromioplasty. Superior capsule reconstruction was performed using the fascia lata. Compared with the intact shoulder, the creation of an irreparable supraspinatus tear significantly shifted the humeral head superiorly in the balanced muscle loading condition (without superior force applied) (0° of abduction: 2.8-mm superior shift [P = .0005]; 30° of abduction: 1.9-mm superior shift [P = .003]) and increased both superior translation (0° of abduction: 239% of intact [P = .04]; 30° of abduction: 199% of intact [P = .02]) and subacromial peak contact pressure (0° of abduction: 308% of intact [P = .0002]; 30° of abduction: 252% of intact [P = .001]) by applying superior force. Superior capsule reconstruction without acromioplasty significantly decreased superior translation (0° of abduction: 86% of intact [P = .02]; 30° of abduction: 75

  12. Predictors and effects of patellofemoral pain following hamstring-tendon ACL reconstruction.

    Science.gov (United States)

    Culvenor, Adam G; Collins, Natalie J; Vicenzino, Bill; Cook, Jill L; Whitehead, Timothy S; Morris, Hayden G; Crossley, Kay M

    2016-07-01

    Patellofemoral pain is a frequent and troublesome complication following anterior cruciate ligament reconstruction (ACLR), irrespective of graft source. Yet, little is known about the factors associated with patellofemoral pain following hamstring-tendon ACLR. Retrospective analysis of potential patellofemoral pain predictors, and cross-sectional analysis of possible patellofemoral pain consequences. Potential predictors (pre-injury patellofemoral pain and activity level, concomitant patellofemoral cartilage damage and meniscectomy, age, sex, and surgical delay) and consequences (hopping performance, quality of life, kinesiophobia, and return to sport rates and attitudes) of patellofemoral pain 12 months following hamstring-tendon ACLR were assessed in 110 participants using univariate and multivariate analyses. Thirty-three participants (30%) had patellofemoral pain at 12 months post-ACLR. Older age at the time of ACLR was the only predictor of post-operative patellofemoral pain. Following ACLR, those with patellofemoral pain had a higher body mass index, and worse physical performance, quality of life, kinesiophobia and return to sport attitudes. Patellofemoral pain has a significant burden on individuals 12 months following hamstring-tendon ACLR. Clinicians need to be cognisant of patellofemoral pain, particularly in older individuals and those with a higher body mass index. The importance of considering psychological factors that are not typically addressed during ACLR rehabilitation, such as kinesiophobia, quality of life and return to sport attitudes is emphasised. Copyright © 2016. Published by Elsevier Ltd.

  13. One-stage Pelnac Reconstruction in Full-thickness Skin Defects with Bone or Tendon Exposure

    Directory of Open Access Journals (Sweden)

    Xianghong Lou, MS

    2018-03-01

    Full Text Available Summary:. Dermal regeneration template, such as Integra and Pelnac, was originally designed for treating large area burn injury by inducing regeneration of dermis. To date, it has been widely applied in various acute and chronic wound sites. The present study demonstrated that application of artificial dermis alone induced 1-stage wound healing for wounds with bone or tendon exposure that should usually be repaired by flap surgery. Eight patients who presented with skin defects with bone and/or tendon exposure were treated by 1-stage Pelnac approach. All wounds healed within 20 weeks without skin graft or flap surgery. The wound area was reconstructed by nearly normal skin structure and linear scar. In the case of scalp defect, evidence of hair follicle cell migration and regeneration during healing process was observed. Thereby, the 1-stage Pelnac reconstitution can be considered as a novel method for inducing regrowth of epidermis and hair follicles to cure large full-thickness skin defect with bone and tendon exposure in 1 stage.

  14. Knee flexor strength recovery following hamstring tendon harvest for anterior cruciate ligament reconstruction: a systematic review

    Directory of Open Access Journals (Sweden)

    Clare Ardern

    2009-07-01

    Full Text Available The hamstring tendons are an increasingly popular graft choice for anterior cruciate ligament reconstruction due to preservation of quadriceps function and the absence of anterior knee pain post-operatively. Two commonly used hamstring grafts are a quadruple strand semitendinosus graft (4ST and a double strand semitendinosus-double strand gracilis graft (2ST-2G. It has been suggested that concurrent harvest of the semitendinsous and gracilis tendons may result in sub-optimal hamstring strength recovery as the gracilis may play a role in reinforcing the semitendinosus particularly in deep knee flexion angles. The objective of this systematic review was to synthesize the findings of available literature and determine whether semitendinosus and gracilis harvest lead to post-operative hamstring strength deficits when compared to semitendinosus harvest alone. Seven studies were identified which compared hamstring strength outcomes between the common hamstring graft types. The methodological quality of each paper was assessed, and where possible effect sizes were calculated to allow comparison of results across studies. No differences were reported between the groups in isokinetic hamstring strength. Deficits in hamstring strength were reported in the 2ST-2G groups when compared to the 4ST groups in isometric strength testing at knee flexion angles ≥70°, and in the standing knee flexion angle. Preliminary evidence exists to support the hypothesis that harvesting the semitendinosus tendon alone is preferable to harvesting in combination with the gracilis tendon for minimizing post-operative hamstring strength deficits at knee flexion angles greater than 70°. However, due to the paucity of research comparing strength outcomes between the common hamstring graft types, further investigation is warranted to fully elucidate the implications for graft harvest.

  15. Anatomic Double-Bundle Anterior Cruciate Ligament Reconstruction With a Free Quadriceps Tendon Autograft.

    Science.gov (United States)

    Caterev, Sergiu; Nistor, Dan Viorel; Todor, Adrian

    2016-10-01

    Anatomic double-bundle anterior cruciate ligament (ACL) reconstruction aims to restore the 2 functional bundles of the ACL in an attempt to better reproduce the native biomechanics of the injured knee and promote long-term knee health. However, this concept is not fully accepted and is not performed on a standard basis. In addition, the superiority of this technique over the conventional single-bundle technique has been questioned, especially the long-term clinical results. One of the down sides of the double-bundle reconstruction is the complexity of the procedure, with increased risks, operative time, and costs compared with the single-bundle procedure. Also, the revision procedure, if necessary, is more challenging. We propose a technique that has some advantages over the traditional double-bundle procedure, using a single femoral tunnel, 2 tibial tunnels, and a free quadriceps tendon autograft.

  16. A mini-invasive adductor magnus tendon transfer technique for medial patellofemoral ligament reconstruction: a technical note.

    Science.gov (United States)

    Sillanpää, Petri J; Mäenpää, Heikki M; Mattila, Ville M; Visuri, Tuomo; Pihlajamäki, Harri

    2009-05-01

    Patellar dislocations are associated with injuries to the medial patellofemoral ligament (MPFL). Several techniques for MPFL reconstruction have been recently published with some disadvantages involved, including large skin incisions and donor site morbidity. Arthroscopic stabilizing techniques carry the potential of inadequate restoration of MPFL function. We present a minimally invasive technique for MPFL reconstruction using adductor magnus tendon autograft. This technique is easily performed, safe, and provides a stabilizing effect equal to current MPFL reconstructions. Skin incision of only 3-4 cm is located at the level of the proximal half of the patella. After identifying the distal insertion of the adductor magnus tendon, a tendon harvester is introduced to harvest the medial two-thirds of the tendon, while the distal insertion is left intact. The adductor magnus tendon is cut at 12-14 cm from its distal insertion and transferred into the patellar medial margin. Two suture anchors are inserted through the same incision at the superomedial aspect of the patella in the anatomic MPFL origin. The graft is tightened at 30 degrees knee flexion. Aftercare includes 4 weeks of brace treatment with restricted range of motion.

  17. Do peak torque angles of muscles change following anterior cruciate ligament reconstruction using hamstring or patellar tendon graft?

    Science.gov (United States)

    Yosmaoğlu, Hayri Baran; Baltacı, Gül; Sönmezer, Emel; Özer, Hamza; Doğan, Deha

    2017-12-01

    This study aims to compare the effects of anterior cruciate ligament (ACL) reconstruction using autogenous hamstring or patellar tendon graft on the peak torque angle. The study included 132 patients (103 males, 29 females; mean age 29±9 year) who were performed ACL reconstruction with autogenous hamstring or patellar tendon graft. The peak torque angles in the quadriceps and hamstring muscles were recorded using an isokinetic dynamometer. Angle of peak knee flexion torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the hamstring tendon group. Angle of peak knee extension torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the patellar tendon group. There were no statistically significant differences in the flexion and extension peak torque angles between the operated and nonoperated knees at 60°/second in both groups. The angle of peak torque at relatively high angular velocities is affected after ACL reconstruction in patients with hamstring or patellar tendon grafts. The graft donor site directly influences this parameter. This finding may be important for clinicians in terms of preventing re-injury.

  18. Anterior cruciate ligament- and hamstring tendon- derived cells: in vitro differential properties of cells involved in ACL reconstruction

    NARCIS (Netherlands)

    Ghebes, C.A.; Kelder, C.; Schot, T.; Renard, A.J.S.; Pakvis, D.F.M.; Fernandes, H.; Saris, Daniël B.F.

    2015-01-01

    Anterior cruciate ligament (ACL) reconstruction involves the replacement of the torn ligament with a new graft, often a hamstring tendon (HT). Described as similar, the ACL and HT have intrinsic differences related to their distinct anatomical locations. From a cellular perspective, identifying

  19. Transportal anterior cruciate ligament reconstruction with quadrupled hamstring tendon graft: A prospective outcome study

    Directory of Open Access Journals (Sweden)

    Chandan Kumar

    2017-01-01

    Full Text Available Background: Anterior cruciate ligament (ACL reconstruction has been one of the most commonly performed procedures throughout the world. Unsatisfactory outcome with conventional ACL reconstruction has been attributed to nonanatomic graft placement. Researchers have advised placing the graft in the native footprint of ACL to avoid nonanatomic graft placement. The goal of this study was to analyze the outcome of anatomic single bundle ACL reconstruction using transportal technique. Materials and Methods: This was a prospective outcome study conducted on 85 consecutive patients of ACL reconstruction of which 62 patients met inclusion and exclusion criteria and were analyzed for final results. All the patients underwent ACL reconstruction by quadrupled hamstring tendon graft using transportal technique and the accessory anteromedial (AAM portal for femoral tunnel creation. The graft was fixed with endobutton on femoral side and bioabsorbable screw on the tibial side. Patients were evaluated for range of motion, International Knee Documentation Committee (IKDC score, and Lysholm scores at a minimum followup period of 2 years. The mean pre- and postoperative scores were compared using Wilcoxon signed-rank test. Results: The mean Lysholm and IKDC scores improved significantly (P < 0.0001 from preoperative value. According to IKDC score, 90.3% (n = 56 were either normal or near normal at final followup. According to Lysholm score, 75.8% of patients had excellent and 13.3% had good results. Preoperatively, pivot shift was present in 85.5% (n = 53 of patients which reduced to 4.8% (n = 3 postoperatively. Infection and knee stiffness occurred in two patients, and femoral tunnel blowout and graft re-rupture occurred in one patient each. Conclusion: Anatomic ACL reconstruction by AAM portal is a reproducible technique which gives good clinical outcome at short-term followup.

  20. Arthroscopic intra- and extra-articular anterior cruciate ligament reconstruction with gracilis and semitendinosus tendons: a review

    OpenAIRE

    Marcacci, Maurilio; Zaffagnini, Stefano; Marcheggiani Muccioli, Giulio Maria; Neri, Maria Pia; Bondi, Alice; Nitri, Marco; Bonanzinga, Tommaso; Grassi, Alberto

    2011-01-01

    The purposes of this paper are to summarize the concepts relating to the use of a combined intra-articular and extra-articular reconstructive procedure in the arthroscopic treatment of a torn ACL and to review several operative techniques utilizing gracilis and semitendinosus tendons that are currently in use to treat this instability. The highly satisfactory results obtained over the time show that a combination of intra- and extra-articular procedures for ACL reconstruction is a valid surgi...

  1. Modified Weaver-Dunn Procedure Versus The Use of Semitendinosus Autogenous Tendon Graft for Acromioclavicular Joint Reconstruction.

    Science.gov (United States)

    Hegazy, Galal; Safwat, Hesham; Seddik, Mahmoud; Al-Shal, Ehab A; Al-Sebai, Ibrahim; Negm, Mohame

    2016-01-01

    The optimal operative method for acromioclavicular joint reconstruction remains controversial. The modified Weaver-Dunn method is one of the most popular methods. Anatomic reconstruction of coracoclavicular ligaments with autogenous tendon grafts, widely used in treating chronic acromioclavicular joint instability, reportedly diminishes pain, eliminates sequelae, and improves function as well as strength. To compare clinical and radiologic outcomes between a modified Weaver-Dunn procedure and an anatomic coracoclavicular ligaments reconstruction technique using autogenous semitendinosus tendon graft. Twenty patients (mean age, 39 years) with painful, chronic Rockwood type III acromioclavicular joint dislocations were subjected to surgical reconstruction. In ten patients, a modified Weaver-Dunn procedure was performed, in the other ten patients; autogenous semitendinosus tendon graft was used. The mean time between injury and the index procedure was 18 month (range from 9 - 28). Clinical evaluation was performed using the Oxford Shoulder Score and Nottingham Clavicle Score after a mean follow-up time of 27.8 months. Preoperative and postoperative radiographs were compared. In the Weaver-Dunn group the Oxford Shoulder Score improved from 25±4 to 40±2 points. While the Nottingham Clavicle Score increased from 48±7 to 84±11. In semitendinosus tendon graft group, the Oxford Shoulder Score improved from 25±3 points to 50±2 points and the Nottingham Clavicle Score from 48±8 points to 95±8, respectively. Acromioclavicular joint reconstruction using the semitendinosus tendon graft achieved better Oxford Shoulder Score and Nottingham Clavicle Score compared to the modified Weaver-Dunn procedure.

  2. Clinical and radiological outcomes after a quasi-anatomical reconstruction of medial patellofemoral ligament with gracilis tendon autograft.

    Science.gov (United States)

    Monllau, Joan C; Masferrer-Pino, Àngel; Ginovart, Gerard; Pérez-Prieto, Daniel; Gelber, Pablo E; Sanchis-Alfonso, Vicente

    2017-08-01

    To analyse the clinical and radiological outcomes of a quasi-anatomical reconstruction of the medial patellofemoral ligament (MPFL) with a gracilis tendon autograft. Patients with objective recurrent patellar instability that were operated on from 2006 to 2012 were included. A quasi-anatomical surgical technique was performed using a gracilis tendon autograft. It was anatomically attached at the patella, and the adductor magnus tendon was also used as a pulley for femoral fixation (non-anatomical reconstruction). The IKDC, Kujala and Lysholm scores as well as Tegner and VAS for pain were collected preoperatively and at final follow-up. Radiographic measurements of patellar position tilt and signs of osteoarthritis (OA) as well as trochlear dysplasia were also recorded. Thirty-six patients were included. The mean age at surgery was 25.6 years. After a minimum 27 months of follow-up, all functional scores significantly improved (p patellofemoral surfaces at the short term, as shown by the absence of radiological signs of OA in the CT scan. The procedure has been shown to be safe and suitable for the treatment of chronic patellar instability, including in adolescents with open physis. A new effective, inexpensive and easy-to-perform technique is described to reconstruct MPFL in the daily clinical practice. Therapeutic case series, Level IV.

  3. Medial Patellofemoral Ligament Reconstruction Using the Hamstring Tendon for Patellofemoral Joint Instability in an 81-Year-Old Female.

    Science.gov (United States)

    Takahashi, Tsuneari; Takeshita, Katsushi

    2017-01-01

    Chronic patellofemoral instability occurs mainly in adolescent females and can also be induced by medial patellofemoral ligament (MPFL) injury. There are no case reports of MPFL reconstruction for chronic patellofemoral instability due to MPFL injury in aged populations. 81-year-old female presented with left knee pain, giving way, and patellar instability while climbing stairs, which continued for 18 months. Patellar apprehension test was positive, and roentgenogram showed lateral patellar subluxation. Conservative therapy was not successful; hence, we performed a lateral release and MPFL reconstruction surgery. After arthroscopic lateral release, the hamstring tendon was harvested, and a graft composite made of doubled hamstring tendon and polyester tape with a suspensory fixation device was prepared. Then, a femoral bone tunnel was constructed in a socket shape at the anatomical footprint of the MPFL. The graft was passed through the femoral tunnel, and free ends of the graft composite were sutured to the periosteum of the patella, using two suture anchors at 60° of knee flexion with patellar reduction. Physiotherapy was gradually started using a patella-stabilizing orthosis on the first postoperative day. Her Kujala score improved from 66 to 97 points, and Barthel index score improved from 70 to 100 points at 1 year after surgery. She neither developed patellofemoral joint OA nor had any recurrence of symptoms at the 5-year postoperative follow up. MPFL reconstruction using the hamstring tendon is an effective procedure for patients with chronic patellofemoral instability even after the age of 80 years.

  4. Double-bundle PCL reconstruction using autologous hamstring tendons: outcome with a minimum 2-year follow-up

    Directory of Open Access Journals (Sweden)

    Ricardo de Paula Leite Cury

    Full Text Available ABSTRACT OBJECTIVE: To present the outcomes of posterior cruciate ligament (PCL double-bundle reconstruction using autologous hamstring tendons, with a minimum follow-up of two years. METHODS: Evaluation of 16 cases of PCL injury that underwent double-bundle reconstruction with autogenous hamstring tendons, between 2011 and 2013. The final sample consisted of 16 patients, 15 men and one woman, with a mean age of 31 years (21-49. The predominant mechanism was motorcycle accident in half of the cases. There was a mean interval of 15 months between the time of lesion and the surgery (three to 52 months. Five lesions were isolated and 11, associated. Clinical evaluation, application of validated scores, and measurements with use of the KT-1000 were performed. RESULTS: The analysis showed a mean preoperative Lysholm score of 50 points (28-87, progressing to 94 points (85-100 postoperatively. The IKDC score also demonstrated improvement. In the preoperative evaluation, four and 12 patients were respectively classified as C (abnormal and D (very unusual, and in the postoperative evaluation six as A (normal and ten as B (close to normal. In the post-operative evaluation by KT1000 arthrometer, 13 patients showed difference between 0-2 mm and 3 between 3 and 5 mm, when compared with the contralateral side. CONCLUSION: Autologous hamstring tendons are a viable option in double-bundle reconstruction of the PCL, with good clinical results in a minimum follow-up of two years.

  5. Anatomic double-bundle anterior cruciate ligament reconstruction using hamstring tendons with minimally required initial tension.

    Science.gov (United States)

    Mae, Tatsuo; Shino, Konsei; Matsumoto, Norinao; Natsu-Ume, Takashi; Yoneda, Kenji; Yoshikawa, Hideki; Yoneda, Minoru

    2010-10-01

    Our purpose was to clarify the clinical outcomes at 2 years after anatomic double-bundle anterior cruciate ligament (ACL) reconstruction with 20 N of the initial tension, which was the minimally required initial tension to perform the reconstruction successfully according to our previous report about the pre-tension necessary to restore the laxity found in the opposite knee (7.3 N; range, 2.2 to 14 N). Of 64 patients who underwent anatomic double-bundle ACL reconstruction with autogenous semitendinosus tendon, 45 were periodically examined for 2 years. Two double-looped grafts were fixed with EndoButton CL devices (Smith & Nephew Endoscopy, Andover, MA) on the femoral side and Double Spike Plates (Smith & Nephew Endoscopy) on the tibial side, while a total of 20 N of initial tension (10 N to each graft) was applied at 20° of knee flexion. The International Knee Documentation Committee Knee Examination Form and Lysholm score were used for the subjective assessment, whereas range of motion and knee stability were evaluated as the objective assessment. Grafts were evaluated in 25 patients with second-look arthroscopy. According to the International Knee Documentation Committee subjective assessment, 62% of knees were graded as normal and 38% as nearly normal. The Lysholm score was 72 points in the preoperative period and improved to 99 points at 2 years' follow-up. A loss of knee extension of less than 3° was found in 2 patients. The pivot-shift test was evaluated as negative in all patients except for 5 as a glide. KT-2000 knee arthrometer side-to-side difference (MEDmetric, San Diego, CA) was 0.1 ± 0.9 mm at 2 years' follow-up. Of the subset of grafts evaluated by second-look arthroscopy, most were considered to have good synovial coverage and to be taut. The anatomic double-bundle ACL reconstruction with 20 N of low initial tension yielded good clinical outcomes at 2 years postoperatively, and second-look arthroscopic findings were excellent. Level IV

  6. One-stage bilateral anterior cruciate ligament reconstruction with use of hamstring tendon autografts: a case report

    Directory of Open Access Journals (Sweden)

    Matjaž Sajovic

    2007-12-01

    Full Text Available Background: Bilateral ACL rupture is not a common clinical problem, but the incidence of the bilateral knee injuries is increasing especially within highly sports active population. Mechanism of the injury rarely causes simultaneous bilateral ACL tear. Usually unilateral injury of the knee has occurred and later on contralateral injury has taken place.Patient and methods: Case report presented an unusual problem of a patient with chronic bilateral ACL – deficient knees and constitutionally very thin patellar tendons. Author decided to perform onestage bilateral ACL reconstructions using hamstring tendon autographs so as not too weaken his quadriceps muscles by compromising his extensor mechanism.Results: At three years follow-up the patient’s opinion was that both ACL reconstructed knees had normal function, and he had returned to his preinjury activity level. The overall result of the Lysholm knee score for left knee was 100 and for right one 95. Both knees had full range of motion, Lachman and pivot shift signs were negative.Conclusions: Two-stage bilateral ACL reconstruction is much more time consuming for the patient and expensive for health insurance, so one-stage bilateral ACL reconstruction is a logical solution of the problem.

  7. Negative pressure wound therapy in the management of late deep infections after open reconstruction of achilles tendon rupture.

    Science.gov (United States)

    Mosser, Philipp; Kelm, Jens; Anagnostakos, Konstantinos

    2015-01-01

    Infection is a major complication after open reconstruction of Achilles tendon ruptures. We report on the use of vacuum-assisted closure (VAC) therapy in the treatment of late deep infections after open Achilles tendon reconstruction. Six patients (5 males [83.33%], 1 female [16.67%]; mean age, 52.8 [range 37 to 66] years) were been treated using an identical protocol. Surgical management consisted of debridement, lavage, and necrectomy of infected tendon parts. The VAC therapy was used for local wound preconditioning and infection management. A continuous negative pressure of 125 mm Hg was applied on each wound. For final wound closure, a split-thickness skin graft was performed. The skin graft healing process was also supported by VAC therapy during the first 5 days. The VAC dressings were changed a mean average of 3 (range 1 to 4) times until split-thickness skin grafting could be performed. The mean total duration of the VAC therapy was 13.6 ± 5.9 days. The mean hospital stay was 31.2 ± 15.9 days. No complications with regard to bleeding, seroma, or hematoma formation beneath the skin graft were observed. At a mean follow-up duration of 29.9 (range 4 to 65) months, no re-infection or infection persistence was observed. The VAC device seems to be a valuable tool in the treatment of infected tendons. The generalization of these conclusions should await the results of future studies with larger patient series. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Functional and magnetic resonance imaging evaluation after single-tendon rotator cuff reconstruction

    DEFF Research Database (Denmark)

    Knudsen, H B; Gelineck, J; Søjbjerg, Jens Ole

    1999-01-01

    The aim of this study was to investigate tendon integrity after surgical repair of single-tendon rotator cuff lesions. In 31 patients, 31 single-tendon repairs were evaluated. Thirty-one patients were available for clinical assessment and magnetic resonance imaging (MRI) at follow-up. A standard...... series of MR images was obtained for each. The results of functional assessment were scored according to the system of Constant. According to MRI evaluation, 21 (68%) patients had an intact or thinned rotator cuff and 10 (32%) had recurrence of a full-thickness cuff defect at follow-up. Patients...... with an intact or thinned rotator cuff had a median Constant score of 75.5 points; patients with a full-thickness cuff defect had a median score of 62 points. There was no correlation between tendon integrity on postoperative MR images and functional outcome. Patients with intact or thinned cuffs did not have...

  9. Outcomes of the patellar tendon and hamstring graft anterior cruciate ligament reconstructions in patients aged above 50 years

    Directory of Open Access Journals (Sweden)

    Tarun Bali

    2015-01-01

    Full Text Available Background: The treatment of anterior cruciate ligament (ACL injury consists of arthroscopic ACL reconstruction with patellar tendon or hamstring graft. Satisfactory results have been reported so far in the younger age group. Dilemma arises regarding the suitability of ACL reconstruction in the patients aged 50 years and above. This retrospective analyses the outcome of ACL reconstruction in patients aged 50 years and above at the time of presentation. Materials and Methods: 55 patients aged 50 years and above presented to our institution with symptomatic ACL tear and were managed with arthroscopic reconstruction with patellar tendon/hamstring graft. 22 patients underwent ACL reconstruction with bone- patellar tendon-bone graft and the remaining 33 with a hamstring graft. Evaluation of functional outcome was performed using International Knee Documentation Committee (IKDC and Lysholm scoring in the preoperative period, at the end of 1 year and at the final followup. Radiographic evaluation was performed using the Kellgren–Lawrence grading system. Results: The mean preoperative IKDC score was 39.7 ± 3.3. At the end of 1-year following the operation, the mean IKDC score was 73.6 ± 4.9 and at the final followup was 67.8 ± 7.7. The mean preoperative Lysholm score was 40.4 ± 10.3. At the end of 1-year following the intervention, the mean Lysholm score was 89.7 ± 2.1 and at final followup was 85.3 ± 2.5. Overall, 14 out of 42 patients who underwent radiographic assessment showed progression of osteoarthritis changes at the final followup after the intervention. Conclusion: In our study, there was a statistically significant improvement in the IKDC and Lysholm scores following the intervention. There was a slight deterioration in the scores at the final followup but the overall rate of satisfaction was still high and most of the patients were able to do their routine chores and light exercises suitable for their age group. Around one-third of

  10. [Reconstruction of medial patellofemoral ligament with transposition of great adductor muscular tendon for the treatment of teenagers' recurrent patellar dislocation].

    Science.gov (United States)

    Shao, Chuan-Qiang; Chen, Chang-Chun; Zhao, Chun-Cheng; Yang, Hong-Mei; Kang, Yan-Zhong

    2017-06-25

    To investigate surgical method and clinical curative effects of medial patellofemoral ligament (MPFL) reconstruction with great adductor muscular tendon in treating teenagers' recurrent patellar dislocation. From May 2012 to September 2014, 19 patients with recurrent dislocation of patellar, including 6 males and 13 females with an average of 16 years old (ranged from 13 to 17 years), the courses of disease ranged from 3 to 18 months(averaged 6 months). All patients were underwent great adductor muscular tendon transposition to reconstruct medial patellofemoral ligament. The curative effects were evaluated by preoperative and postoperative with Lysholm scores and Patellofemoral angle and Q angle. All patients were followed up from 12 to 18 months with an average of 16.5 months. Primary healing was achieved at stage I. No pain, swelling and patellar dislocation or subluxation occurred. Patellofemoral angle increased from preoperative (-3.8±4.9)° to (10.3±4.1)° postoperatively. Q angle decreased from preoperative(16.4±3.1)° to(10.5±1.2)° postoperatively; Lysholm scores were improved from preoperative (68.6±8.5) to (93.7±6.5) final follow-up ( P teenagers' recurrent patellar dislocation.

  11. Three-Dimensional Bio-Printed Scaffold Sleeves With Mesenchymal Stem Cells for Enhancement of Tendon-to-Bone Healing in Anterior Cruciate Ligament Reconstruction Using Soft-Tissue Tendon Graft.

    Science.gov (United States)

    Park, Sin Hyung; Choi, Yeong-Jin; Moon, Sang Won; Lee, Byung Hoon; Shim, Jin-Hyung; Cho, Dong-Woo; Wang, Joon Ho

    2018-01-01

    To investigate the efficacy of the insertion of 3-dimensional (3D) bio-printed scaffold sleeves seeded with mesenchymal stem cells (MSCs) to enhance osteointegration between the tendon and tunnel bone in anterior cruciate ligament (ACL) reconstruction in a rabbit model. Scaffold sleeves were fabricated by 3D bio-printing. Before ACL reconstruction, MSCs were seeded into the scaffold sleeves. ACL reconstruction with hamstring tendon was performed on both legs of 15 adult rabbits (aged 12 weeks). We implanted 15 bone tunnels with scaffold sleeves with MSCs and implanted another 15 bone tunnels with scaffold sleeves without MSCs before passing the graft. The specimens were harvested at 4, 8, and 12 weeks. H&E staining, immunohistochemical staining of type II collagen, and micro-computed tomography of the tunnel cross-sectional area were evaluated. Histologic assessment was conducted with a histologic scoring system. In the histologic assessment, a smooth bone-to-tendon transition through broad fibrocartilage formation was identified in the treatment group, and the interface zone showed abundant type II collagen production on immunohistochemical staining. Bone-tendon healing histologic scores were significantly higher in the treatment group than in the control group at all time points. Micro-computed tomography at 12 weeks showed smaller tibial (control, 9.4 ± 0.9 mm 2 ; treatment, 5.8 ± 2.9 mm 2 ; P = .044) and femoral (control, 9.6 ± 2.9 mm 2 ; treatment, 6.0 ± 1.0 mm 2 ; P = .03) bone-tunnel areas in the treated group than in the control group. The 3D bio-printed scaffold sleeve with MSCs exhibited excellent results in osteointegration enhancement between the tendon and tunnel bone in ACL reconstruction in a rabbit model. If secure biological healing between the tendon graft and tunnel bone can be induced in the early postoperative period, earlier, more successful rehabilitation may be facilitated. Three-dimensional bio-printed scaffold sleeves with

  12. Synthetic Augmented Suture Anchor Reconstruction for a Complete Traumatic Distal Triceps Tendon Rupture in a Male Professional Bodybuilder with Postoperative Biomechanical Assessment

    Directory of Open Access Journals (Sweden)

    Maria-Elissavet Nikolaidou

    2014-01-01

    Full Text Available Bodybuilding is a high-risk sport for distal triceps tendon ruptures. Management, especially in high-demanding athletes, is operative with suture anchor refixation technique being frequently used. However, the rate of rerupture is high due to underlying poor tendon quality. Thus, additional augmentation could be useful. This case report presents a reconstruction technique for a complete traumatic distal triceps tendon rupture in a bodybuilder with postoperative biomechanical assessment. A 28-year-old male professional bodybuilder was treated with a synthetic augmented suture anchor reconstruction for a complete triceps tendon rupture of his right dominant elbow. Postoperative biomechanical assessment included isokinetic elbow strength and endurance testing by using multiple angular velocities to simulate the “off-season” and “precompetition” phases of training. Eighteen months postoperatively and after full return to training, the biomechanical assessment indicated that the strength and endurance of the operated elbow joint was fully restored with even higher ratings compared to the contralateral healthy arm. The described reconstruction technique can be considered as an advisable option in high-performance athletes with underlying poor tendon quality due to high tensile strength and lack of donor site morbidity, thus enabling them to restore preinjury status and achieve safe return to sports.

  13. Synthetic Augmented Suture Anchor Reconstruction for a Complete Traumatic Distal Triceps Tendon Rupture in a Male Professional Bodybuilder with Postoperative Biomechanical Assessment

    Science.gov (United States)

    Nikolaidou, Maria-Elissavet; Banke, Ingo J.; Laios, Thomas; Petsogiannis, Konstantinos; Mourikis, Anastasios

    2014-01-01

    Bodybuilding is a high-risk sport for distal triceps tendon ruptures. Management, especially in high-demanding athletes, is operative with suture anchor refixation technique being frequently used. However, the rate of rerupture is high due to underlying poor tendon quality. Thus, additional augmentation could be useful. This case report presents a reconstruction technique for a complete traumatic distal triceps tendon rupture in a bodybuilder with postoperative biomechanical assessment. A 28-year-old male professional bodybuilder was treated with a synthetic augmented suture anchor reconstruction for a complete triceps tendon rupture of his right dominant elbow. Postoperative biomechanical assessment included isokinetic elbow strength and endurance testing by using multiple angular velocities to simulate the “off-season” and “precompetition” phases of training. Eighteen months postoperatively and after full return to training, the biomechanical assessment indicated that the strength and endurance of the operated elbow joint was fully restored with even higher ratings compared to the contralateral healthy arm. The described reconstruction technique can be considered as an advisable option in high-performance athletes with underlying poor tendon quality due to high tensile strength and lack of donor site morbidity, thus enabling them to restore preinjury status and achieve safe return to sports. PMID:24711944

  14. Effects of knee immobilization on morphological changes in the semitendinosus muscle-tendon complex after hamstring harvesting for anterior cruciate ligament reconstruction. Evaluation using three-dimensional computed tomography

    International Nuclear Information System (INIS)

    Nakamae, Atsuo; Adachi, Nobuo; Nakasa, Tomoyuki; Nishimori, Makoto; Ochi, Mitsuo; Deie, Masataka

    2012-01-01

    It is desirable to maintain the morphology of the semitendinosus muscle-tendon complex after tendon harvesting for anterior cruciate ligament (ACL) reconstruction. The purpose of this study was to evaluate the effect of knee immobilization on morphological changes in the semitendinosus muscle-tendon complex. In total, 39 patients who underwent ACL reconstruction with autologous semitendinosus tendons were included in this study. After surgery, the knee was immobilized for 3 days in 1 group of patients (group 1; 24 patients; control group) and for a longer period (10-14 days) in the other group (group 2; 15 patients). Three-dimensional computed tomography (3D CT) examination was performed at 6 and/or 12 months after the surgery for all patients. Morphological changes in the semitendinosus muscle-tendon complex (proximal shift of the semitendinosus muscle-tendon junction, width of the regenerated semitendinosus tendons, re-insertion sites of the regenerated tendons, and rate of semitendinosus tendon regeneration) were evaluated. Successful regeneration of the semitendinosus tendon was confirmed in all patients in group 2. In group 1, 3D CT showed that regeneration of the semitendinosus tendon was unsuccessful in 1 of the 24 patients. The average length of the proximal shift of the semitendinosus muscle-tendon junction was 7.3±2.5 cm in group 1 and 7.2±1.9 cm in group 2. There were no significant differences between the 2 groups with regard to the morphological changes in the semitendinosus muscle-tendon complex. This study showed that the structure of regenerated tendons could be clearly identified in 38 of 39 cases (97.4%) after ACL reconstruction. However, prolonged knee immobilization (10-14 days) could not prevent morphological changes in the semitendinosus muscle-tendon complex. (author)

  15. TMJ ankylosis: Management with reconstruction and interpositional ...

    African Journals Online (AJOL)

    Temporomandibular joint (TMJ) ankylosis is a very desolating structural condition that involves fusion of the 1 mandibular condyle to the base of the skull. It causes difficulty in mastication and breathing.Trauma and Infections are usually responsible.If trauma occurs in young age,it leads to disturbance in growth & facial ...

  16. ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION: A COMPARISON BETWEEN BONE PATELLAR TENDON BONE GRAFT AND LIPSCOMB PROCEDURE - A FOLLOWUP STUDY OF 7 YEARS

    Directory of Open Access Journals (Sweden)

    Vijayamohan S

    2016-07-01

    Full Text Available BACKGROUND Anterior Cruciate Ligament injury has become more common and the demand by the patients to return to pre-injury level of activity has made reconstruction of the ligament very crucial. Though there are various techniques in reconstructing the anterior cruciate ligament, in this study, we compare two most commonly used techniques to see whether there is any significant difference in the outcome. METHODS Study included 25 patients in the age group of 19-36 years, of which 23 were males. The patients were divided randomly into 2 groups, and 15 patients underwent Anterior Cruciate Ligament reconstruction using Bone Patellar Tendon Bone Graft and 10 patients had Hamstring graft. RESULTS Patients were followed up at regular intervals monthly for the first six months and then at three monthly intervals. Patients were assessed using Knee Scoring Scale of Lysholm and Gillquist and International Knee Documentation Committee (IKDC scoring system. In addition, activity level, harvest site pain, thigh atrophy, kneeling pain and hamstring pain were assessed. All patients were followed up for a minimum period of 2 years. 20% of both groups were able to return to strenuous activity level, and 67% of Patellar tendon group and 50% of the Hamstring tendon group were able to return to moderate level of activity. 55% of patients in the patellar tendon group and 20% of patients in the hamstring tendon group had donor site pain in the first 6 months. 73% of patients in the hamstring group had at least 10 mm of thigh wasting. Pain on kneeling was seen only in the patellar tendon group (35% while hamstring pain was found only in the hamstring group (20%. CONCLUSIONS Patients in the patellar tendon group had increased anterior stability and were able to return to strenuous occupation. The difference in thigh atrophy between the two groups was not significant. The hamstring group had lower graft harvest site morbidity. Lachman test was the single most accurate

  17. Assessment of rotatory instability after anterior cruciate ligament reconstruction with a bone-patellar tendon-bone graft

    International Nuclear Information System (INIS)

    Tashiro, Yasutaka; Okazaki, Ken; Miura, Hiromasa

    2010-01-01

    Anatomically oriented anterior cruciate ligament (ACL) reconstruction has been advocated recently, but its effect on rotatory instability remains to be cleared objectively. The purpose of this study was to quantitatively evaluate rotatory instability in ACL reconstructed knees with a bone-patellar tendon-bone (BTB) graft using an open MRI system. Eighteen subjects underwent arthroscopic ACL reconstruction with a BTB graft. The tibial tunnel was placed in the center of the ACL footprint. The femoral tunnel was drilled transtibially at the 10:00 to 10:30-o'clock position for the right knees. Subjects were examined using a Slocum anterolateral rotatory instability test in open MRI. Anterior tibial translation was measured at the medial and lateral compartments by evaluating sagittal images. Anterior knee stability was evaluated using the KT-2000 arthrometer. The clinical knee function was assessed with the Lysholm and Tegner scoring scales before and after the surgery. Side-to-side differences of anterolateral tibial translation was 0.1 mm. Side-to-side difference on KT-2000 arthrometer measurement was 1.8 mm. The Lysholm score improved to 96 and the latest Tegner score reached substantially the preinjury level. ACL reconstruction with a BTB graft was successful in restoring rotatory stability as well as anterior stability and knee function. (author)

  18. Aesthetically and functionally satisfying reconstruction of an Achilles tendon and overlying skin defect in a 15 year old girl: a case report.

    Science.gov (United States)

    Wurzer, Paul; Eberl, Robert; Kamolz, Lars-Peter; Parvizi, Daryousch; Rappl, Thomas; Spendel, Stephan

    2015-03-01

    Achilles tendon and overlying soft tissue reconstruction presents an interdisciplinary challenge. In the literature many possible procedures are described, but each reconstruction in this region has its specific demands. Single stage reconstruction is normally pursued, but it is not always the best procedure for the patient, either aesthetically or functionally. We present a case of a 15 year old girl who suffered a soft tissue defect of 10cm×6cm in size at the area of the Achilles tendon due to a contact burn by an exhaust pipe during a motorcycle accident. For this case, reconstruction of the soft tissue defect using a free temporoparietal fascial flap (TPFF) and a full-thickness skin autograft was the best means to provide a satisfying result for both the patient and the surgeon. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  19. Isokinetic evaluation of internal/external tibial rotation strength after the use of hamstring tendons for anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Armour, Tanya; Forwell, Lorie; Litchfield, Robert; Kirkley, Alexandra; Amendola, Ned; Fowler, Peter J

    2004-01-01

    Evaluation of the knee after an anterior cruciate ligament reconstruction with the use of the semitendinosus and gracilis (hamstring) autografts has primarily focused on flexion and extension strength. The semitendinosus and gracilis muscles contribute to internal tibial rotation, and it has been suggested that harvest of these tendons for the purpose of an anterior cruciate ligament reconstruction contributes to internal tibial rotation weakness. Internal tibial rotation strength may be affected by the semitendinosus and gracilis harvest after anterior cruciate ligament reconstruction. Prospective evaluation of internal and external tibial rotation strength. Inclusion criteria for subjects (N = 30): unilateral anterior cruciate ligament reconstruction at least 2 years previously, a stable anterior cruciate ligament (problems after initial knee reconstruction, a normal contralateral knee, and the ability to comply with the testing protocol. In an attempt to minimize unwanted subtalar joint motion, subjects were immobilized using an ankle brace and tested at angular velocities of 60 degrees /s, 120 degrees /s, and 180 degrees /s at a knee flexion angle of 90 degrees . The mean peak torque measurements for internal rotation strength of the operative limb (60 degrees /s, 17.4 +/- 4.5 ft-lb; 120 degrees /s, 13.9 +/- 3.3 ft-lb; 180 degrees /s, 11.6 +/- 3.0 ft-lb) were statistically different compared to the nonoperated limb (60 degrees /s, 20.5 +/- 4.7 ft-lb; 120 degrees /s, 15.9 +/- 3.8 ft-lb; 180 degrees /s, 13.4 +/- 3.8 ft-lb) at 60 degrees /s (P = .012), 120 degrees /s (P = .036), and 180 degrees /s (P = .045). The nonoperative limb demonstrated greater strength at all speeds. The mean torque measurements for external rotation were statistically similar when compared to the nonoperated limb at all angular velocities. We have shown through our study that patients who undergo surgical intervention to repair a torn anterior cruciate ligament with the use of autogenous

  20. Pectoralis Major Tear with Retracted Tendon: How to Fill the Gap? Reconstruction with Hamstring Autograft and Fixation with an Interference Screw

    Directory of Open Access Journals (Sweden)

    L. Baverel

    2017-01-01

    Full Text Available Rupture of the pectoralis major tendon is considered an uncommon injury and a significant number of ruptures are missed or diagnosed late, leading to a chronic tear. We report an open reconstruction technique and its outcomes in a case of chronic and retracted PM tear. At the last follow-up (12 months, the patient was pain-free, with a visual analogic scale at 0 all the time. He was very satisfied concerning the cosmetic and clinical results. The constant score was 93%, the SST value 95%, and the Quick DASH score 4.5. MRI performed one year postoperatively confirmed the continuity between PM tendon and graft, even if the aspect of the distal tendon seemed to be thinner than normal PM tendon. The excellent clinical outcomes at one-year follow-up suggest that PM tear with major tendon retraction can be reliably reconstructed with hamstring autograft, using a bioabsorbable screw to optimize the fixation device. This technique has proven its simplicity and efficiency to fill the gap.

  1. Does Donor Age of Nonirradiated Achilles Tendon Allograft Influence Mid-Term Results of Revision ACL Reconstruction?

    Science.gov (United States)

    Zaffagnini, Stefano; Roberti di Sarsina, Tommaso; Bonanzinga, Tommaso; Nitri, Marco; Macchiarola, Luca; Stefanelli, Federico; Lucidi, Gianandrea; Grassi, Alberto

    2018-01-01

    Purpose  The purpose of the present study was to investigate if the donor age of nonirradiated Achilles tendon allograft could influence the clinical results of revision anterior cruciate ligament (ACL) reconstruction. Methods  All patients that underwent ACL revision between 2004 and 2008 with at least 4 years of follow-up were included. For all the patients that met the inclusion criteria, the age of the graft donor was obtained from the tissue bank. Lysholm score was administered to patients that met inclusion criteria. In addition, patients were divided in two groups based on the donor age (<45 years vs. ≥45 years), and the baseline characteristics and outcomes were compared. Results  Fifty-two patients were evaluated at a mean 4.8 ± 0.8 years follow-up with Lysholm score. The Lysholm significantly improved from 62.3 ± 6.6 at preoperative status to 84.4 ± 12.3 at final follow-up. The mean donor age was 48.7 ± 8.4 years; a significant difference in Lysholm score was noted between patients that received an allograft with a donor age <45 years (14 patients; 27%) and those receiving an allograft with a donor age ≥45 years (38; 73%) (89.5 ± 3.2 vs. 80.1 ± 11.1, respectively; p  = 0.0469). The multiple regression model showed the donor age, the final follow-up, and the preoperative Lysholm score as significant predictors of postoperative Lysholm score ( p  < 0.0002). Conclusion  Donor age of nonirradiated Achilles tendon allograft influenced the mid-term results of revision ACL reconstruction, thus advising the use of grafts from young donors. Level of Evidence  Level III, retrospective comparative study. PMID:29675501

  2. Loss of reduction and complications of coracoclavicular ligament reconstruction with autogenous tendon graft in acute acromioclavicular dislocations.

    Science.gov (United States)

    Choi, Nam Hong; Lim, Seok Min; Lee, Sang Young; Lim, Tae Kang

    2017-04-01

    This study was conducted to report loss of reduction and complications after single-tunnel coracoclavicular (CC) ligament reconstruction with autogenous semitendinosus tendon graft for acute acromioclavicular (AC) joint dislocations. This retrospective study included patients with acute, unstable AC dislocations (surgery within 6 weeks after trauma). We excluded patients with chronic injury and distal clavicle fractures with CC ligaments disruption. We measured the CC distance on anteroposterior radiographs of both clavicles, preoperatively, immediately postoperatively, and at the final follow-up visit. We evaluated clinical outcomes using the American Shoulder and Elbow Surgeons Shoulder Assessment and the University of California, Los Angeles Shoulder Rating Scale scores and perioperative complications. There were 30 patients (27 men and 3 women) with mean age of 41 years (range, 19-70 years). The mean follow-up period was 31 months (range, 12-186 months). Mean CC distance was 15.5 ± 3.7 mm (84% ± 14% of the contralateral shoulder) preoperatively, 8.9 ± 2.6 mm (9% ± 40%) immediately postoperatively (P 25% increase of CC distance) developed in 14 patients (47%), and complications occurred in 6 patients (20%), including 3 distal clavicle fractures through the tunnel. Final clinical scores were significantly lower in patients with complications (27 vs. 33 of the University of California, Los Angeles assessment [P < .001] and 81 vs. 95 of the American Shoulder and Elbow Surgeons Shoulder assessment [P < .001]). In acute AC joint dislocation, single-tunnel CC ligament reconstruction using autogenous tendon graft resulted in loss of reduction rate of 47% and a complication rate of 20%. The development of complications adversely affected clinical outcomes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. Tendon 'turnover lengthening' technique.

    Science.gov (United States)

    Cerovac, S; Miranda, B H

    2013-11-01

    Tendon defect reconstruction is amongst the most technically challenging areas in hand surgery. Tendon substance deficiency reconstruction techniques include lengthening, grafting, two-stage reconstruction and tendon transfers, however each is associated with unique challenges over and above direct repair. We describe a novel 'turnover lengthening' technique for hand tendons that has successfully been applied to the repair of several cases, including a case of attritional flexor and traumatic extensor tendon rupture in two presented patients where primary tenorrhaphy was not possible. In both cases a good post-operative outcome was achieved, as the patients were happy having returned back to normal activities of daily living such that they were discharged 12 weeks post-operatively. Our technique avoids the additional morbidity and complications associated with grafting, transfers and two stage reconstructions. It is quick, simple and reproducible for defects not exceeding 3-4 cm, provides a means of immediate one stage reconstruction, no secondary donor site morbidity and does not compromise salvage by tendon transfer and/or two-stage reconstruction in cases of failure. To our knowledge no such technique has been previously been described to reconstruct such hand tendon defects. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  4. Freeze-dried allograft-mediated gene or protein delivery of growth and differentiation factor 5 reduces reconstructed murine flexor tendon adhesions

    DEFF Research Database (Denmark)

    Svensson, Sys Hasslund; Dadali, Tulin; Ulrich-Vinther, Michael

    2014-01-01

    reverse transcription polymerase chain reaction (RT-PCR), enzyme-linked immunosorbent assay (ELISA), and in vivo bioluminescent imaging. We then reconstructed flexor digitorum longus (FDL) tendons of the mouse hindlimb with allografts loaded with low and high doses of recombinant GDF-5 protein and r......Advances in allograft processing have opened new horizons for clinical adaptation of flexor tendon allografts as delivery scaffolds for antifibrotic therapeutics. Recombinant adeno-associated-virus (rAAV) gene delivery of the growth and differentiation factor 5 (GDF-5) has been previously...... associated with antifibrotic effects in a mouse model of flexor tendoplasty. In this study, we compared the effects of loading freeze-dried allografts with different doses of GDF-5 protein or rAAV-Gdf5 on flexor tendon healing and adhesions. We first optimized the protein and viral loading parameters using...

  5. [EFFECTIVENESS COMPARISON OF CORACOCLAVICULAR LIGAMENT RECONSTRUCTION BETWEEN BY AUTOLOGOUS AND ALLOGENEIC TENDON GRAFTS COMBINED WITH HOOK PLATE FIXATION FOR TREATING ACROMIOCLAVICULAR JOINT DISLOCATION].

    Science.gov (United States)

    Yin, Fei; Sun, Zhenzhong; Wei, Xuming; Liu, Xueguang; Zhou, Ming; Zhuang, Yin; Song, Sheng

    2016-05-08

    To compare the effectiveness of coracoclavicular ligament reconstruction between by using autologous plantaris tendon graft combined with hook plate fixation and allogeneic tendon graft combined with hook plate fixation for treating acromiocavicular joint dislocation. Thirty-three patients with acromioclavicular joint dislocation who accorded with the inclusion criteria between January 2013 and June 2014 were assigned into 2 groups. The patients were treated with autologous plantaris tendon graft combined with hook plate fixation in group A ( n =17), and with allogeneic tendon graft combined with hook plate fixation in group B ( n =16). Thirteen-one patients was followed up more than 12 months (15 in group A and 16 in group B). There was no significant difference in gender, age, cause of injury, sides, time between injury and surgery, and type of dislocation ( P >0.05). The assessments included operation time, hospitalization time, hospitalization expenses, shoulder range of motion, gap of acromioclavicular, Constant-Murley scores, and visual analogue scale (VAS) for pain. The operation time of group A was significantly longer than that of group B, and the hospitalization expense was significantly lower than that of group B ( P 0.05). No redislocation of acromioclavicular joint and rejection reaction occurred during follow-up. At last follow-up, there was no significant difference in shoulder range of motion, Constant-Murley score, and VAS score between 2 groups ( P >0.05). Coracoclavicular ligament reconstruction by autologous plantaris tendon or allogeneic tendon graft combined with hook plate fixation for the treatment of acromioclavicular joint dislocation can achieve good effectiveness. The appropriate treatment should be chosen according to the patient's economic situation.

  6. Hypoglossal-facial-jump-anastomosis without an interposition nerve graft.

    Science.gov (United States)

    Beutner, Dirk; Luers, Jan C; Grosheva, Maria

    2013-10-01

    The hypoglossal-facial-anastomosis is the most often applied procedure for the reanimation of a long lasting peripheral facial nerve paralysis. The use of an interposition graft and its end-to-side anastomosis to the hypoglossal nerve allows the preservation of the tongue function and also requires two anastomosis sites and a free second donor nerve. We describe the modified technique of the hypoglossal-facial-jump-anastomosis without an interposition and present the first results. Retrospective case study. We performed the facial nerve reconstruction in five patients. The indication for the surgery was a long-standing facial paralysis with preserved portion distal to geniculate ganglion, absent voluntary activity in the needle facial electromyography, and an intact bilateral hypoglossal nerve. Following mastoidectomy, the facial nerve was mobilized in the fallopian canal down to its bifurcation in the parotid gland and cut in its tympanic portion distal to the lesion. Then, a tensionless end-to-side suture to the hypoglossal nerve was performed. The facial function was monitored up to 16 months postoperatively. The reconstruction technique succeeded in all patients: The facial function improved within the average time period of 10 months to the House-Brackmann score 3. This modified technique of the hypoglossal-facial reanimation is a valid method with good clinical results, especially in cases of a preserved intramastoidal facial nerve. Level 4. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  7. Anterior-Posterior Instability of the Knee Following ACL Reconstruction with Bone-Patellar Tendon-Bone Ligament in Comparison with Four-Strand Hamstrings Autograft

    Directory of Open Access Journals (Sweden)

    A. G. Angoules

    2013-01-01

    Full Text Available Purpose. To evaluate anterior-posterior knee laxity using two different autografts. Material-Methods. 40 patients, (34 males and 6 women, 17–54 years old (mean: 31, were included in the present study. Group A (4SHS = 20 underwent reconstruction using four-strand hamstrings, and group B (BPBT = 20 underwent reconstruction using bone-patellar tendon-bone autograft. Using the KT-1000 arthrometer, knee instability was calculated in both knees of all patients preoperatively and 3, 6, and 12 months after surgery at the ACL-operated knee. The contralateral healthy knee was used as an internal control group. Results. Anterior-posterior instability using the KT1000 Arthrometer was found to be increased after ACL insufficiency. The recorded laxity improved after arthroscopic ACL reconstruction in both groups. However, statistically significant greater values were detected in the bone-patellar tendon-bone group, which revealed reduction of anteroposterior stability values to an extent, where no statistical significance with the normal values even after 3 months after surgery was observed. Conclusions. Anterior-Posterior instability of the knee improved significantly after arthroscopic ACL reconstruction. The bone-patellar tendon-bone graft provided an obvious greater stability.

  8. FUNCTIONAL OUTCOME OF ACCELERATED REHABILITATION IN ARTHROSCOPIC ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION WITH BONE PATELLAR TENDON BONE GRAFT A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Hiranyakumar

    2016-03-01

    Full Text Available INTRODUCTION An ideal rehabilitation program post anterior cruciate ligament reconstruction enables an individual to return to pre injury levels at a faster rate with minimal to no risk of reinjury to the graft. Rehabilitation protocols have changed considerably over time in the past. It has become “aggressive”, meaning an intensive rehabilitation which includes greater variety of exercises and sports related training. AIM OF THE STUDY The aim of our study is to assess the outcome of accelerated rehabilitation post anterior cruciate ligament (ACL reconstruction. METHODOLOGY 106 patients were operated by a single surgeon underwent arthroscopic anterior cruciate ligament reconstruction using bone patella tendon bone graft and partial meniscectomy for associated meniscal tear. Patients were put on an accelerated rehabilitation protocol designed in our institute on first post-operative day, under the guidance of a physical therapist in consultation with the operated surgeon. Patients were followed up at 3 weeks, 6 months and 9 months, post onset of rehabilitation, patients were assessed using KT1000 Arthrometer and Lysholm knee scoring system. RESULTS Out of 106 patients, who were selected, 96(91% were males and 10(9% were females. The mean pre-operative Lysholm score was 55.09. Post operatively, while on accelerated rehabilitation program the Lysholm scores were 69.73 at 3 weeks, 89.13 at 6 months and 89.19 at 9 months. In our pre-operative evaluation mean KT 1000 arthrometer score was 10.53 and post-operative at six months was 3.49. At nine months 105 patients had excellent results whereas 1 patient had good result. CONCLUSION Accelerated rehabilitation protocol enables the patient to functionally recover faster to pre injury levels. A rehabilitation protocol for 6 months is sufficient in enabling a patient to get back to pre-injury levels. Functional outcome is the same with or without associated meniscal injuries.

  9. Allograft tendon reconstruction of the anterior talofibular ligament and calcaneofibular Ligament in the treatment of chronic ankle instability.

    Science.gov (United States)

    Wang, Weikai; Xu, Guo Hong

    2017-04-08

    The purpose was retrospectively to investigate functional and clinical outcomes after anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL) reconstruction using a single allograft. Patients with severe chronic lateral instability of the ankle underwent surgery after conservative treatment failed. Ultrasounds of the ankle were performed, and if the AFTL and CFL were completely torn without enough soft tissue for repair, the ligaments were reconstructed using allograft tendon. Outcomes were assessed by clinical examination, stress radiography, ultrasound, the American Orthopaedic Foot and Ankle Society score (AOFAS), and Karlsson Ankle Functional score (KAFS) before surgery and at final follow-up. Nineteen patients, ten men and nine women with mean age of 27.9 years (range, 19-41 years), underwent reconstruction. Mean follow-up was 30 months (range, 24-40 months). At final follow-up, all patients had returned to activity without instability, pain, or limited range of motion. On stress radiography, mean talar tilt angle decreased from 17.32° ± 3.58° before surgery to 4.16° ± 1.12° at follow-up (p surgery to 3.97 ± 0.99 mm at follow-up (p < 0.05). Mean AOFAS improved from 64.00 ± 18.43 to 90.32 ± 5.17 points (p < 0.001), and mean KAFS improved from 50.84 ± 16.73 to 90.89 ± 5.08 points (p < 0.001). Ultrasound showed the reconstructed ligaments maintained good continuity and excellent tension. No case of infection and immunological rejection was reported. This novel reconstruction technique takes into account the anatomical specialty of AFTL and CFL. This case series showed increased stability of the ankle in clinical and functional outcomes. The trial registration number (TRN) and date of registration: ChiCTR-ORC-17010796 , Mar 6th 2017. Retrospectively registered.

  10. Iliotibial band autograft versus bone-patella-tendon-bone autograft, a possible alternative for ACL reconstruction

    DEFF Research Database (Denmark)

    Stensbirk, Frederik; Thorborg, Kristian; Konradsen, Lars

    2014-01-01

    PURPOSE: The long-term results after using the iliotibial band autograft (ITB) in anterior cruciate ligament (ACL) reconstruction are not fully known. If equal in quality to conventional methods, the ITB graft could be a useful alternative as a primary graft, in revision surgery or multi-ligament......PURPOSE: The long-term results after using the iliotibial band autograft (ITB) in anterior cruciate ligament (ACL) reconstruction are not fully known. If equal in quality to conventional methods, the ITB graft could be a useful alternative as a primary graft, in revision surgery or multi...

  11. Acromioclavicular joint dislocation: a comparative biomechanical study of the palmaris-longus tendon graft reconstruction with other augmentative methods in cadaveric models

    Directory of Open Access Journals (Sweden)

    Sengupta S

    2007-11-01

    Full Text Available Abstract Background Acromioclavicular injuries are common in sports medicine. Surgical intervention is generally advocated for chronic instability of Rockwood grade III and more severe injuries. Various methods of coracoclavicular ligament reconstruction and augmentation have been described. The objective of this study is to compare the biomechanical properties of a novel palmaris-longus tendon reconstruction with those of the native AC+CC ligaments, the modified Weaver-Dunn reconstruction, the ACJ capsuloligamentous complex repair, screw and clavicle hook plate augmentation. Hypothesis There is no difference, biomechanically, amongst the various reconstruction and augmentative methods. Study Design Controlled laboratory cadaveric study. Methods 54 cadaveric native (acromioclavicular and coracoclavicular ligaments were tested using the Instron machine. Superior loading was performed in the 6 groups: 1 in the intact states, 2 after modified Weaver-Dunn reconstruction (WD, 3 after modified Weaver-Dunn reconstruction with acromioclavicular joint capsuloligamentous repair (WD.ACJ, 4 after modified Weaver-Dunn reconstruction with clavicular hook plate augmentation (WD.CP or 5 after modified Weaver-Dunn reconstruction with coracoclavicular screw augmentation (WD.BS and 6 after modified Weaver-Dunn reconstruction with mersilene tape-palmaris-longus tendon graft reconstruction (WD. PLmt. Posterior-anterior (horizontal loading was similarly performed in all groups, except groups 4 and 5. The respective failure loads, stiffnesses, displacements at failure and modes of failure were recorded. Data analysis was carried out using a one-way ANOVA, with Student's unpaired t-test for unpaired data (S-PLUS statistical package 2005. Results Native ligaments were the strongest and stiffest when compared to other modes of reconstruction and augmentation except coracoclavicular screw, in both posterior-anterior and superior directions (p WD.ACJ provided additional

  12. Dorsal capsulodesis associated with arthoscopy-assisted scapholunate ligament reconstruction using a palmaris longus tendon graft

    Directory of Open Access Journals (Sweden)

    Victor Bignatto Carvalho

    Full Text Available ABSTRACT OBJECTIVES: To measure the quality of life, the time to work return, and clinical, functional, and radiographic parameters of patients treated with dorsal capsulodesis associated with scapholunate (SL reconstruction, assisted by arthroscopy. METHODS: From January 2015 to September 2016, 14 adult patients with SL dissociation underwent surgical treatment with the SL reconstruction procedure assisted by arthroscopy, using the new technique proposed in this study. All patients were assessed by the occupational therapy department at regular intervals after surgery and performed the same sequence of rehabilitation. The parameters analyzed were: range of motion (ROM, Disability of the Arm, Shoulder, and Hand (DASH, visual analog scale (VAS, and radiographic analysis to visualize the pre- and postoperative SL gap and the pre- and postoperative dorsal intercalated segment instability (DISI deformity the. The complications and the time to return to work activities were described. RESULTS: The follow-up time was 12 months (3-17. The ROM averaged 321° (96.9% of the normal side. VAS was 1.79/10 (1-6. DASH was 6.50/100 (1-30. The time to work return work was 4.42 months (2-17. As for complications, one patient developed SLAC, and underwent four-corner fusion one year after ligament reconstruction. Currently, he has experienced pain relief, with a functional range of motion of the wrist, and has not yet returned to professional activities. The preoperative SL gap was 4.29 mm (2-7; in the postoperative period, it was 1.79 mm (1-4. The DISI deformity was present in ten patients with SL angle > 70° (preoperative and it was corrected after surgery, in all patients. SLAC stage I was identified in a patient. Arthroscopy was performed in all cases. The SL instability was classified as Geissler grade III in four cases and as grade IV in ten cases. CONCLUSION: The new approach (dorsal capsulodesis associated with SL reconstruction, assisted by arthroscopy

  13. In Vivo Study of Ligament-Bone Healing after Anterior Cruciate Ligament Reconstruction Using Autologous Tendons with Mesenchymal Stem Cells Affinity Peptide Conjugated Electrospun Nanofibrous Scaffold

    Directory of Open Access Journals (Sweden)

    Jingxian Zhu

    2013-01-01

    Full Text Available Electrospinning nanofibrous scaffold was commonly used in tissue regeneration recently. Nanofibers with specific topological characteristics were reported to be able to induce osteogenic differentiation of MSCs. In this in vivo study, autologous tendon grafts with lattice-like nanofibrous scaffold wrapping at two ends of autologous tendon were used to promote early stage of ligament-bone healing after rabbit ACL reconstruction. To utilize native MSCs from bone marrow, an MSCs specific affinity peptide E7 was conjugated to nanofibrous meshes. After 3 months, H-E assessment and specific staining of collagen type I, II, and III showed direct ligament-bone insertion with typical four zones (bone, calcified fibrocartilage, fibrocartilage, and ligament in bioactive scaffold reconstruction group. Diameters of bone tunnel were smaller in nanofibrous scaffold conjugated E7 peptide group than those in control group. The failure load of substitution complex also indicated a stronger ligament-bone insertion healing using bioactive scaffold. In conclusion, lattice-like nanofibrous scaffold with specific MSCs affinity peptide has great potential in promoting early stage of ligament-bone healing after ACL reconstruction.

  14. [Excision of accessory navicular with reconstruction of posterior tibial tendon insertion on navicular for treatment of flatfoot related with accessory navicular].

    Science.gov (United States)

    Cao, Honghui; Tang, Kanglai; Deng, Yinshuan; Tan, Xiaokang; Zhou, Binghua; Tao, Xu; Chen, Lei; Chen, Qianbo

    2012-06-01

    To analyze the excision of accessory navicular with reconstruction of posterior tibial tendon insertion on navicular for the treatment of flatfoot related with accessory navicular and to evaluate its effectiveness. Between May 2006 and June 2011, 33 patients (40 feet) with flatfoot related with accessory navicular were treated. There were 14 males (17 feet) and 19 females (23 feet) with an average age of 30.1 years (range, 16-56 years). All patients had bilateral accessory navicular; 26 had unilateral flatfoot and 7 had bilateral flatfeet. The disease duration ranged from 7 months to 9 years (median, 24 months). The American Orthopaedic Foot and Ankle Society (AOFAS) ankle-midfoot score was 47.9 +/- 7.3. The X-ray films showed type II accessory navicular, the arch height loss, and heel valgus in all patients. All of them received excision of accessory navicular and reconstruction of posterior tibial tendon insertion on navicular with anchor. All patients got primary wound healing without any complication. Thirty patients (36 feet) were followed up 6-54 months with an average of 23 months. All patients achieved complete pain relief at 6 months after surgery and had good appearance of the feet. The AOFAS ankle-midfoot score was 90.4 +/- 2.0 at last follow-up, showing significant difference when compared with preoperative score (t=29.73, P=0.00). X-ray films showed that no screw loosening or breakage was observed. There were significant differences in the arch height, calcaneus inclination angle, talocalcaneal angle, and talar-first metatarsal angle between pre-operation and last follow-up (P < 0.01). The excision of accessory navicular with reconstruction of posterior tibial tendon insertion on navicular is a good choice for the treatment of flatfoot related with accessory navicular, with correction of deformity, excellent effectiveness, and less complications.

  15. A surprise case of colonic interposition

    International Nuclear Information System (INIS)

    Law, Robert

    2006-01-01

    Blind nasogastric intubation failure as a result of changes to the normal anatomical pathway is not uncommon. This case report is of fluoroscopically guided intubation in a patient in whom blind intubation failed as a result of what was subsequently found to be a colonic interposition with associated late complications. Fluroscopically guided nasogastric intubation is a safe and effective procedure that should always be considered when blind intubation has failed

  16. All-Inside Single-Bundle Reconstruction of the Anterior Cruciate Ligament with the Anterior Half of the Peroneus Longus Tendon Compared to the Semitendinosus Tendon: A Two-Year Follow-Up Study.

    Science.gov (United States)

    Bi, Mingguang; Zhao, Chen; Zhang, Shuijun; Yao, Bin; Hong, Zheping; Bi, Qing

    2018-02-08

    The anterior half of the peroneus longus tendon (AHPLT) has been reported to be acceptable for ligament reconstruction with respect to strength and safety. However, there is little information regarding the clinical outcomes after using the AHPLT compared with other autograft tendons. A prospective randomized controlled study was performed to compare the results of 62 cases of all-inside anatomical single-bundle anterior cruciate ligament (ACL) reconstruction using the AHPLT and 62 cases using semitendinosus graft with an average of 30.0 ± 3.6 months' follow-up. Tunnel placements of enrolled cases were measured on three-dimensional (3D) computed tomography (CT) and X-ray imaging. Knee stability was assessed using the anterior drawer test, pivot shift test, and KT-1000. The International Knee Documentation Committee (IKDC) 2000 subjective score was used to evaluate functional outcomes. The American Orthopedic Foot and Ankle Score (AOFAS) and the assessment of eversion muscle strength were performed to evaluate the function of the ankle donor site. Tunnel positions, which were confirmed with 3D CT, were in the anatomical positions. At the final follow-up, there were no significant differences between the semitendinosus group and the AHPLT group in the IKDC score (90.4 ± 7.1 vs. 89.3. ± 8.4), KT 1000 measurements (1.71 ± 0.57 vs. 1.85 ± 0.77), pivot shift test, and Visual Analogue Scale (VAS) (0.15 ± 0.36 vs. 0.10 ± 0.30). No obvious ankle site complications were found at 24 months. The average AOFAS score of the AHPLT group was comparable to that of the semitendinosus tendon group (99.1 ± 1.40 vs. 99.5 ± 1.21). There was no significant difference in clinical outcomes or knee stability between the semitendinosus group and the AHPLT group at the 2-year follow-up. An AHPLT autograft may be a good alternative for all-inside ACL reconstruction with respect to its strength, safety, and donor site morbidity. Thieme Medical

  17. Influence of the initial rupture size and tendon subregion on three-dimensional biomechanical properties of single-row and double-row rotator cuff reconstructions.

    Science.gov (United States)

    Lorbach, O; Pape, D; Raber, F; Busch, L C; Kohn, D; Kieb, M

    2012-11-01

    Influence of the initial rotator cuff tear size and of different subregions of the SSP tendon on the cyclic loading behavior of a modified single-row reconstruction compared to a suture-bridging double-row repair. Artificial tears (25 and 35 mm) were created in the rotator cuff of 24 human cadaver shoulders. The reconstructions were performed as a single-row repair (SR) using a modified suture configuration or a suture-bridge double-row repair (DR). Radiostereometric analysis was used under cyclic loading (50 cycles, 10–180 N, 10–250 N) to calculate cyclic displacement in three different planes (anteroposterior (x), craniocaudal (y) and mediolateral (z) level). Cyclic displacement was recorded, and differences in cyclic displacement of the anterior compared to the posterior subregions of the tendon were calculated. In small-to-medium tears (25 mm) and medium-to-large tears (35 mm), significant lower cyclic displacement was seen for the SR-reconstruction compared to the DR-repair at 180 N (p ≤ 0.0001; p = 0.001) and 250 N (p = 0.001; p = 0.007) in the x-level. These results were confirmed in the y-level at 180 N (p = 0.001; p = 0.0022) and 250 N (p = 0.005; p = 0.0018). Comparison of the initial tear sizes demonstrated significant differences in cyclic displacement for the DR technique in the x-level at 180 N (p = 0.002) and 250 N (p = 0.004). Comparison of the anterior versus the posterior subregion of the tendon revealed significant lower gap formation in the posterior compared to the anterior subregions in the x-level for both tested rotator cuff repairs (p ≤ 0.05). The tested single-row repair using a modified suture configuration achieved superior results in three-dimensional measurements of cyclic displacement compared to the tested double-row suture-bridge repair. The results were dependent on the initial rupture size of the rotator cuff tear. Furthermore, significant differences were found between tendon subregions of the rotator cuff with

  18. Silicone infusion tubing instead of Hunter rods for two-stage zone 2 flexor tendon reconstruction in a resource-limited surgical environment.

    Science.gov (United States)

    Kibadi, K; Moutet, F

    2017-10-01

    The authors describe their experience using silicone infusion tubing in place of Hunter rods for two-stage zone 2 flexor tendon reconstruction in a resource-limited surgical environment. This case report features a 47-year-old, right-handed man who had no active PIP and DIP joint flexion in four fingers of the right hand 5 months after an injury. During the first repair stage, the A2 and A4 pulleys were reconstructed using an extensor retinaculum graft. An infusion tube was inserted instead of Hunter rods. During the second stage, formation of a digital neo-canal around the infusion tubing was observed. The infusion tubing was removed and replaced with a palmaris longus tendon graft according to the conventional technique. Physiotherapy and rehabilitation followed surgery. At 6 months, very significant progress had been made with complete recovery of PIP and DIP flexion in the four fingers. Copyright © 2017 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  19. Biology and augmentation of tendon-bone insertion repair

    OpenAIRE

    Lui, PPY; Zhang, P; Chan, KM; Qin, L

    2010-01-01

    Abstract Surgical reattachment of tendon and bone such as in rotator cuff repair, patellar-patella tendon repair and anterior cruciate ligament (ACL) reconstruction often fails due to the failure of regeneration of the specialized tissue ("enthesis") which connects tendon to bone. Tendon-to-bone healing taking place between inhomogenous tissues is a slow process compared to healing within homogenous tissue, such as tendon to tendon or bone to bone healing. Therefore special attention must be ...

  20. Peri-Vesical Fat Interposition Flap Reinforcement in High Vesico ...

    African Journals Online (AJOL)

    Background and Aim: The urinary bladder becomes small, contracted and is associated with excess pelvic fat in long standing cases of vesico-vaginal fistulas (VVFs). The aim of this new technique was to use this excess pelvic fat for harvesting an interposition flap. Materials and Methods: An interposition flap of peri-vesical ...

  1. Anterior cruciate ligament reconstruction using bone plug-free quadriceps tendon autograft: intermediate-term clinical outcome after 24-36 months.

    Science.gov (United States)

    Schulz, Arndt P; Lange, Vivien; Gille, Justus; Voigt, Christine; Fröhlich, Susanne; Stuhr, Markus; Jürgens, Christian

    2013-01-01

    Although known as a possible graft option for decades, quadriceps tendon grafts have often been termed a second-line graft option. We report a consecutive case series using this method as the primary treatment line. The rationale for this study was to evaluate the midterm results of this method in a prospective and consecutive case series. The primary study question was to determine the clinical results 24-36 months after primary anterior cruciate ligament (ACL) reconstruction using a bone plug-free quadriceps tendon autograft fixed with bioabsorbable cross-pins. The study population included 55 patients, of whom 24 were female (43.6%). The mean age at the index procedure was 31.7 years (15-58 years). All patients received an ACL construction using a bone block-free quadriceps tendon graft fixed with resorbable cross-pins. The postoperative regimen included partial weight-bearing for 3 weeks and flexion limited to 90° for six weeks; an orthosis was not used. The mean follow-up duration was 29.5 months (24.3-38.5 months) after the index procedure. The International Knee Documentation Committee (IKDC) subjective score and examination form was assessed, as well as the Lysholm and Gillquist score and the Tegner activity index. The Rolimeter arthrometer was used to assess the anterior laxity of the knee. Graft harvesting was possible in all cases; a bony extension was never required. On average, graft length was measured at 8.8 cm (7.5-10 cm). The mean IKDC subjective score at follow-up was 80.44 points (55.17-100 points, standard deviation [SD] 12.05). The mean preinjury Tegner activity index was 4.98 (2-7) compared to a mean value of 4.16 (2-7, SD 0.8) at follow-up. There was a mean loss of 0.82 index points. The average Lysholm and Gillquist score was 89 points (65-100, SD 17.7). Of the results, 89.1% were in the good or very good groups; in one case (1.8%), the result was poor, while the rest were fair. ACL reconstruction using a bone plug-free quadriceps tendon

  2. Achilles Tendonitis

    Science.gov (United States)

    ... almost impossible. Achilles tendonitis is a very common running injury. But it can also affect basketball players, dancers, ... Proximal Biceps Tendonitis Safety Tips: Basketball Safety Tips: Running Repetitive Stress Injuries Sports and Exercise Safety Dealing With Sports Injuries ...

  3. Coracoclavicular ligament reconstruction with the autogenous anterior half of the peroneus longus tendon for distal clavicle fracture (Neer type Ⅱ-b: A report of 26 cases

    Directory of Open Access Journals (Sweden)

    Guang-you YANG

    2017-12-01

    Full Text Available Objective To explore the clinical effect of coracoclavicular ligament reconstruction with the autogenous anterior half of peroneus longus tendon (AHPLT for distal clavicle fracture (Neer type Ⅱ-b. Methods The clinical data were retrospectively analyzed of 26 Neer type Ⅱ-b distal clavicle fracture surgically treated by coracoclavicular ligament reconstruction with autogenous AHPLT in Ganyu District People's Hospital of Lianyungang from June 2012 to May 2015. Among the 26 cases, 16 males and 10 females, aged from 19-56 years (average 38.7 years. Fracture occurred in left side in 18 cases and in right side in 8 cases. Postoperative observations were done on fracture healing, shoulder and ankle-foot function recovery. Results For all the 26 cases, surgical incisions were healed well, and no infection, vascular and peroneal nerve injury and iatrogenic fracture occurred. Follow-up was carried out for 10-24 months with average of 15.3 months. All the fractures were healed within 12-20 weeks with an average of 14.6 weeks. One patient was found of losing the fracture reduction part during the follow-up process, and then got eventual healing by extending the limb brake time. Another patient was found of slight tendon sensation disorder with no significant effect on daily life and exercise, and the symptoms disappeared 6 months later. At the last follow-up, the Constant-Murley score was 92-100 with an average of 97.8 points. The ankle-hind foot score of American Society of Ankle and Orthopedics was excellent. Conclusion Reconstruction of coracoclavicular ligament with autogenous AHPLT is an effective treatment for Neer type Ⅱ-b distal clavicle fracture with good safety and without negative effect on the ankle-foot function, and thus it is worthy of wider clinical use. DOI: 10.11855/j.issn.0577-7402.2017.12.12

  4. A retrospective review of bone tunnel enlargement after anterior cruciate ligament reconstruction with hamstring tendons fixed with a metal round cannulated interference screw in the femur.

    Science.gov (United States)

    Kobayashi, Masahiko; Nakagawa, Yasuaki; Suzuki, Takashi; Okudaira, Shuzo; Nakamura, Takashi

    2006-10-01

    To assess bone tunnel enlargement after anterior cruciate ligament (ACL) reconstruction with the use of hamstring tendons fixed with a round cannulated interference (RCI) screw in the femur. A consecutive series of 30 ACL reconstructions performed with hamstring tendons fixed with an RCI screw in the femur and with staples via Leeds-Keio ligament in the tibia was retrospectively reviewed. The clinical outcome was evaluated through the Lysholm score. Anterior instability was tested by Telos-SE (Telos Japan, Tokyo, Japan) measurement. The location and angle of each femoral and tibial tunnel were measured with the use of plain radiographs, and bone tunnel enlargement greater than 2 mm detected any time 3, 6, 12, and 24 months postoperatively was defined as positive. Each factor (location and angle of the tunnels, sex, affected side, age, Lysholm score, and Telos-SE measurement) was compared between enlarged and nonenlarged groups. Positive enlargement of the bone tunnel (>2.0 mm) was observed in 36.7% (11 of 30) on the femoral side and 33.3% (10 of 30) on the tibial side, and in 6 knees of both sides. Half of patients (15 of 30) had an enlarged tunnel on the femoral or the tibial side until 1 year postoperatively. In most cases, enlargement reached maximum at 6 months postoperatively. Female patients tended to have an enlarged tunnel, especially on the femoral side (P < .05). Tunnel enlargement was not correlated with location and angle of the tunnels. Moreover, no difference was found in Lysholm score and Telos-SE measurement between enlarged and nonenlarged groups, although the nonenlarged group tended to exhibit higher Lysholm score and lesser instability. Bone tunnel enlargement of the femoral or tibial side was observed in half of patients (6 in both sides, 5 only in the femur, and 4 only in the tibia) after ACL reconstruction was performed with a hamstring tendon fixed with an RCI screw. Female patients had a greater chance for enlargement of the femoral tunnel

  5. Anterior cruciate ligament reconstruction using bone plug-free quadriceps tendon autograft: intermediate-term clinical outcome after 24–36 months

    Directory of Open Access Journals (Sweden)

    Schulz AP

    2013-11-01

    Full Text Available Arndt P Schulz,1 Vivien Lange,2 Justus Gille,1 Christine Voigt,3 Susanne Fröhlich,4 Markus Stuhr,1 Christian Jürgens5 1Department of Orthopedics, Trauma, and Sports Medicine, University Hospital Lübeck, Lübeck, Germany; 2Department of Rehabilitation, Sana Regio Klinikum, Wedel, Germany; 3Department of Sports Medicine and Arthroscopy, Diakoniekrankenhaus Friederikenstift, Hannover, Germany; 4Department of Orthopedics, University of Rostock, Rostock, Germany; 5Department of Orthopedics, Trauma, and Sports Medicine, BG Trauma Hospital Hamburg, Hamburg, Germany Introduction: Although known as a possible graft option for decades, quadriceps tendon grafts have often been termed a second-line graft option. We report a consecutive case series using this method as the primary treatment line. The rationale for this study was to evaluate the midterm results of this method in a prospective and consecutive case series. The primary study question was to determine the clinical results 24–36 months after primary anterior cruciate ligament (ACL reconstruction using a bone plug-free quadriceps tendon autograft fixed with bioabsorbable cross-pins. Materials and methods: The study population included 55 patients, of whom 24 were female (43.6%. The mean age at the index procedure was 31.7 years (15–58 years. All patients received an ACL construction using a bone block-free quadriceps tendon graft fixed with resorbable cross-pins. The postoperative regimen included partial weight-bearing for 3 weeks and flexion limited to 90° for six weeks; an orthosis was not used. The mean follow-up duration was 29.5 months (24.3–38.5 months after the index procedure. The International Knee Documentation Committee (IKDC subjective score and examination form was assessed, as well as the Lysholm and Gillquist score and the Tegner activity index. The Rolimeter arthrometer was used to assess the anterior laxity of the knee. Results: Graft harvesting was possible in all cases

  6. Interposition of the gallbladder in the common hepatic duct: a rare dangerous anomaly. Case report.

    Science.gov (United States)

    Rosato, L; Ginardi, A; Mondini, G

    2011-01-01

    Anomalies of the gallbladder position in the biliary tract are rare, but they could be very dangerous during cholecystectomy. A 48-year-old man presented with a 2-week history of intermittent epigastric pain, scleral jaundice and elevation of liver function tests. After a magnetic resonance cholangiogram and an endoscopic retrograde cholangiogram with sphincterotomy, he was submitted to laparoscopic cholecystectomy, the conversion to laparotomy was decided for the suspect of gallbladder interposition. The anatomical anomaly was confirmed and a Roux-en-Y hepaticojejunostomy was executed, with end-to-side anastomosis between the confluence of the hepatic ducts and the fourth loop of jejunum, on a biliary stent. This catheter was removed in the tenth postoperative day; after cholangiography and CT abdominal scan the patient was discharged, without complications. The gallbladder interposition is a rare malformation which seems to arise from an embryonic anomaly occurring between the 4th and the 5th week and whose potential causes have not been detected. A similar outcome could be also determined by a Mirizzi syndrome, but in our case it is excluded because intra-operatively there was no inflammatory reaction that could justify the presence of a fistula between the gallbladder and the common hepatic duct. Once the gallbladder interposition is found, the surgical treatment consists in removing the gallbladder itself and the corresponding part of the common hepatic duct. The reconstruction is carried out by a Roux-en-Y hepaticojejunostomy with anastomosis at the hepatic hilum, positioning a biliary stent.

  7. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model

    OpenAIRE

    Li, Shengkun; Ma, Kui; Li, Hong; Jiang, Jia; Chen, Shiyi

    2016-01-01

    The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET) artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA) is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired w...

  8. Bioresorbable pins and interference screws for fixation of hamstring tendon grafts in anterior cruciate ligament reconstruction surgery: a randomized controlled trial.

    Science.gov (United States)

    Stengel, Dirk; Casper, Dirk; Bauwens, Kai; Ekkernkamp, Axel; Wich, Michael

    2009-09-01

    Biodegradable cross-pins have been shown to provide higher failure loads than do screws for fixation of hamstring tendons under laboratory conditions. To compare the clinical results of biodegradable pins (RigidFix) and interference screws (BioCryl) for fixation of hamstring grafts in arthroscopically assisted anterior cruciate ligament reconstruction. Study Design Randomized controlled trial; Level of evidence, 1. To test the hypothesis of a difference of 1.0 +/- 1.2 mm in anterior knee laxity between the two fixation options, 54 patients were randomly assigned to groups via a block randomization scheme and sealed envelopes. All patients underwent standardized hamstring graft reconstruction and had similar postoperative aftercare by an accelerated rehabilitation protocol. Measures assessed at baseline and after 1 and 2 years of follow-up included (1) the side-to-side difference in anterior laxity (KT-1000 arthrometer), (2) Short Form 36 physical and mental component scores, and (3) the International Knee Documentation Committee form scores. After 1 and 2 years, 26 and 21 patients in the BioCryl group and 28 and 24 patients in the RigidFix group were available for follow-up examination. No significant difference was noted in instrumented anterior translation between BioCryl and RigidFix fixation: 1 year, 0.11 (95% CI, -0.60 to 0.82; P = .7537); 2 years, 0.33 (95% CI, -0.43 to 1.08 mm; P = .3849). Also, there were no significant differences in the mean physical and mental component scores and International Knee Documentation Committee form scores and in overall complication and surgical revision rates. A pin dislocation was classified as the sole procedure-specific serious adverse event. Bioresorbable pins do not provide better clinical results than do resorbable interference screws for hamstring graft fixation in anterior cruciate ligament reconstruction surgery.

  9. Hamstrings tendon graft preparation for anterior cruciate ligament reconstruction using the WhipKnotTM soft tissue cinch technique.

    Directory of Open Access Journals (Sweden)

    Amin Masoumiganjgah

    2012-04-01

    Full Text Available BackgroundAppropriate graft tension and secure graft incorporation inbone tunnels are essential for successful anterior cruciateligament (ACL reconstruction using hamstrings tendonautografts. The WhipKnot™ soft tissue cinch, introduced bySmith and Nephew in 2004, is an alternative option to thecommonly used whipstitch technique during preparation ofthe hamstring autograft in ACL reconstruction.AimsTo investigate the effectiveness of the WhipKnot™ softtissue cinch and technique during the preparation of thetendon graft for ACL reconstruction.MethodA total of 33 ACL reconstruction operations performedbetween February 2011 and December 2011 were includedin this study. These were performed by a single seniorsurgeon who used the Whipknot™ technique for thepreparation of each graft. Four were used for eachoperation; two for each end of the harvested hamstringstendons, including semitendinosus and gracilis tendonsrespectively.ResultsIn total, 132 WhipKnots were used during the kneeoperations. Use of the WhipKnot™ technique resulted insuccessful graft preparations, tensioning and effective graftplacement in the tibial and femoral tunnels in almost allinstances. Only one case of WhipKnot™ failure (slippagewas recorded.ConclusionThese results indicate that the Whipknot™ technique is asafe, reliable and practical option for the preparation of thehamstrings autografts.

  10. Use of a strontium-enriched calcium phosphate cement in accelerating the healing of soft-tissue tendon graft within the bone tunnel in a rabbit model of anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Kuang, G M; Yau, W P; Lu, W W; Chiu, K Y

    2013-07-01

    We investigated whether strontium-enriched calcium phosphate cement (Sr-CPC)-treated soft-tissue tendon graft results in accelerated healing within the bone tunnel in reconstruction of the anterior cruciate ligament (ACL). A total of 30 single-bundle ACL reconstructions using tendo Achillis allograft were performed in 15 rabbits. The graft on the tested limb was treated with Sr-CPC, whereas that on the contralateral limb was untreated and served as a control. At timepoints three, six, nine, 12 and 24 weeks after surgery, three animals were killed for histological examination. At six weeks, the graft-bone interface in the control group was filled in with fibrovascular tissue. However, the gap in the Sr-CPC group had already been completely filled in with new bone, and there was evidence of the early formation of Sharpey fibres. At 24 weeks, remodelling into a normal ACL-bone-like insertion was found in the Sr-CPC group. Coating of Sr-CPC on soft tissue tendon allograft leads to accelerated graft healing within the bone tunnel in a rabbit model of ACL reconstruction using Achilles tendon allograft.

  11. Step Cut Lengthening: A Technique for Treatment of Flexor Pollicis Longus Tendon Rupture.

    Science.gov (United States)

    Chong, Chew-Wei; Chen, Shih-Heng

    2018-04-01

    Reconstruction of a tendon defect is a challenging task in hand surgery. Delayed repair of a ruptured flexor pollicis longus (FPL) tendon is often associated with tendon defect. Primary repair of the tendon is often not possible, particularly after debridement of the unhealthy segment of the tendon. As such, various surgical treatments have been described in the literature, including single-stage tendon grafting, 2-stage tendon grafting, flexor digitorum superficialis tendon transfer from ring finger, and interphalangeal joint arthrodesis. We describe step cut lengthening of FPL tendon for the reconstruction of FPL rupture. This is a single-stage reconstruction without the need for tendon grafting or tendon transfer. To our knowledge, no such technique has been previously described.

  12. Over-the-top ACL Reconstruction Plus Extra-articular Lateral Tenodesis With Hamstring Tendon Grafts: Prospective Evaluation With 20-Year Minimum Follow-up.

    Science.gov (United States)

    Zaffagnini, Stefano; Marcheggiani Muccioli, Giulio Maria; Grassi, Alberto; Roberti di Sarsina, Tommaso; Raggi, Federico; Signorelli, Cecilia; Urrizola, Francisco; Spinnato, Paolo; Rimondi, Eugenio; Marcacci, Maurilio

    2017-12-01

    There are few published studies with very long-term follow-up of combined intra- and extra-articular anterior cruciate ligament (ACL) reconstruction. To analyze clinical and radiographic outcomes of over-the-top ACL reconstruction plus extra-articular lateral tenodesis with autologous hamstrings at minimum 20-year follow-up. Case series; Level of evidence, 4. Of 60 originally eligible patients who underwent over-the-top ACL reconstruction with double-stranded hamstring tendon (leaving intact graft tibial insertions) and extra-articular lateral plasty (performed with the remnant part of tendons), 52 were prospectively evaluated at a minimum 20-year follow-up (mean follow-up, 24 years; 41 men, 11 women; mean age at time of surgery, 25.5 ± 7.6 years). Twenty-nine patients were available for prospective evaluations: clinical (Lysholm, Tegner, and objective International Knee Documentation Committee [IKDC]), instrumented (KT-2000), and radiographic (standard, long-standing, and Merchant views). Subjective KOOS (Knee injury and Osteoarthritis Outcome Score) and objective inertial sensor pivot-shift analysis (KiRA) were carried out at final follow-up. Twenty-three patients were investigated by phone interview for subjective Tegner score and documented complications, rerupture, or revision surgery. At final follow-up, mean Lysholm score was 85.7 ± 14.6; median Tegner score, 4 (range, 3-5); sport activity resumption, 86.2%; and objective IKDC score, good or excellent in 86% of patients (31%, A; 55%, B). Only 3 of 26 patients (12%) had >5-mm manual maximum KT-2000 side-to-side difference. KiRA system documented positive pivot-shift (>0.9-m/s 2 tibial acceleration side-to-side difference) in these 3 of 26 patients (12%). Statistically significant changes were as follows: decrease in Tegner score from 7 (range, 6-8) at 5-year follow-up to 4 (range, 3-5) at 10 years ( P < .0001) and decrease in Lysholm score from 96.1 ± 7.3 at 10-year follow-up to 85.7 ± 14.6 at 20 years

  13. The effect of isoperistaltic jejunal interposition upon gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Mackie, C.R.; Hall, A.W.; Clark, J.; Wisbey, M.; Baker, P.R.; Cuschieri, A.

    1981-12-01

    Ten patients with severe postgastrectomy-postvagotomy symptoms, all of whom had the features of vasomotor dumping, underwent gastric emptying studies, using a 300 milliliter meal of 15 per cent dextrose labeled with 99mTc-sulphur colloid. Studies were repeated two to 11 months following remedial operative treatment, using a 12.5 to 15.0 centimeter isoperistaltic jejunal interposition. Preoperatively, all patients had rapid gastric emptying with a typical biphasic pattern. Following isoperistaltic interposition, the rate of gastric emptying was similar to that found in control patients. Gastric emptying reverted to a more normal pattern but, as in the preoperative studies, was best described by a double exponential function, consisting of slow and fast components. Analysis of these particular functions suggests the manner in which isoperistaltic interposition modified the underlying disorder of gastric motility.

  14. Outcomes After Interpositional Arthroplasty of the First Metatarsophalangeal Joint.

    Science.gov (United States)

    Aynardi, Michael C; Atwater, Lara; Dein, Eric J; Zahoor, Talal; Schon, Lew C; Miller, Stuart D

    2017-05-01

    For patients with hallux rigidus seeking a motion-sparing procedure, interposition arthroplasty is an alternative to fusion. The purpose of this study was to report patient outcomes after interpositional arthroplasty for hallux rigidus. All patients undergoing interpositional arthroplasty at our institution from 2001 to 2014 were identified and a retrospective chart review was performed. Follow-up was conducted through a telephone survey to obtain survivorship, satisfaction, and functional scores. Survivorship of the interpositional arthroplasty procedure was defined as no subsequent surgery on the hallux after the index procedure. Patients were excluded for incomplete records. Complications were recorded. From 2001 to 2014, 183 patients were identified. Of these, 14 were excluded for incomplete data, leaving 169 patients. Of these, 133 had an average follow-up of 62.2 months (range, 24.3 months to 151.2 months). The overall failure rate was 3.8% (5/133). Patient-reported outcome was rated as excellent in 65.4% (87/133) or good in 24.1% (32/133) of patients and fair or poor in 10.5% (14/133) of patients. Of 133 patients, 101 (76%) were able to return to fashionable or regular footwear. The infection rate was 1.5% (2/133). Patient-reported cock-up deformity of the first metatarsophalangeal joint (MTPJ) occurred in 4.5% (6/133) of patients. In addition, 17.3% (23/133) of patients reported metatarsalgia of the second or third MTPJ at the time of final follow-up, and there was no significant difference between interposition types ( P = .441). Interpositional arthroplasty for hallux rigidus was found to have excellent or good results in most patients at a mean follow-up of 62.2 months. Level IV, retrospective case series.

  15. Bilateral spontaneous rupture of flexor digitorum profundus tendons.

    LENUS (Irish Health Repository)

    O'Sullivan, S T

    2012-02-03

    Spontaneous tendon rupture is an unusual condition usually associated with underlying disease processes such as rheumatoid arthritis, chronic renal failure or bony abnormalities of the hand. We report a case of spontaneous, non-concurrent bilateral rupture of flexor profundus tendons in an otherwise healthy individual. Treatment was successful and consisted of a two-stage reconstruction of the ruptured tendon.

  16. Five-Strand versus Four-Strand Hamstring Tendon Graft Technique for Anterior Cruciate Ligament Reconstruction: A Biomechanical Comparison.

    Science.gov (United States)

    Vaillant, Eric R; Parks, Brent G; Camire, Lyn M; Hinton, Richard Y

    2017-11-01

    The aim of this article is to compare diameter and stiffness, displacement, and strain in a five-strand versus four-strand hamstring graft for anterior cruciate ligament reconstruction. Eight matched pairs of lower extremities underwent four-strand or five-strand hamstring graft reconstruction. Diameter was significantly higher in the five-strand versus the four-strand construct ( p  = 0.002). No significant difference was found between the groups in construct displacement or stiffness. Significantly higher strain was observed in the inner limb versus the outer limb in the four-strand construct ( p  = 0.001) and in the inner limb versus the fifth limb in the 5-strand construct ( p  = 0.004). A fifth limb added to a four-strand hamstring graft significantly increased graft diameter but did not significantly change stiffness or displacement, suggesting that attachment of additional graft material via suture did not provide for full incorporation of the added limb into the graft at time zero. The inner limb in both constructs absorbed significantly greater load than did other limbs. The use of suture to attach additional material to a four-strand hamstring graft may not contribute to improved biomechanical qualities of the graft at time zero. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  17. Talocalcaneal Joint Middle Facet Coalition Resection With Interposition of a Juvenile Hyaline Cartilage Graft.

    Science.gov (United States)

    Tower, Dyane E; Wood, Ryan W; Vaardahl, Michael D

    2015-01-01

    Talocalcaneal joint middle facet coalition is the most common tarsal coalition, occurring in ≤2% of the population. Fewer than 50% of involved feet obtain lasting relief of symptoms after nonoperative treatment, and surgical intervention is commonly used to relieve symptoms, increase the range of motion, improve function, reconstruct concomitant pes planovalgus, and prevent future arthrosis from occurring at the surrounding joints. Several approaches to surgical intervention are available for patients with middle facet coalitions, ranging from resection to hindfoot arthrodesis. We present a series of 4 cases, in 3 adolescent patients, of talocalcaneal joint middle facet coalition resection with interposition of a particulate juvenile hyaline cartilaginous allograft (DeNovo(®) NT Natural Tissue Graft, Zimmer, Inc., Warsaw, IN). With a mean follow-up period of 42.8 ± 2.9 (range 41 to 47) months, the 3 adolescent patients in the present series were doing well with improved subtalar joint motion and decreased pain, and 1 foot showed no bony regrowth on a follow-up computed tomography scan. The use of a particulate juvenile hyaline cartilaginous allograft as interposition material after talocalcaneal middle facet coalition resection combined with adjunct procedures to address concomitant pes planovalgus resulted in good short-term outcomes in 4 feet in 3 adolescent patients. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Ulcerative Colitis in Colonic Interposition for Esophageal Atresia

    OpenAIRE

    Arshad, Hafiz Muhammad Sharjeel; Tetangco, Eula; Elkhatib, Imad

    2016-01-01

    A 38-year-old male with a history of colonic interposition for esophageal atresia as an infant presented with dysphagia and abdominal pain. On the basis of endoscopy findings, pathology, and response to therapy, he was found to have ulcerative colitis of the colonic conduit.

  19. 21 CFR 872.3970 - Interarticular disc prosthesis (interpositional implant).

    Science.gov (United States)

    2010-04-01

    ... implant). 872.3970 Section 872.3970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3970 Interarticular disc prosthesis (interpositional implant). (a) Identification. An interarticular disc prosthesis...

  20. IFSSH Flexor Tendon Committee report 2014: from the IFSSH Flexor Tendon Committee (Chairman: Jin Bo Tang).

    Science.gov (United States)

    Tang, Jin Bo; Chang, James; Elliot, David; Lalonde, Donald H; Sandow, Michael; Vögelin, Esther

    2014-01-01

    Hand surgeons continue to search for the best surgical flexor tendon repair and treatment of the tendon sheaths and pulleys, and they are attempting to establish postoperative regimens that fit diverse clinical needs. It is the purpose of this report to present the current views, methods, and suggestions of six senior hand surgeons from six different countries - all experienced in tendon repair and reconstruction. Although certainly there is common ground, the report presents provocative views and approaches. The report reflects an update in the views of the committee. We hope that it is helpful to surgeons and therapists in treating flexor tendon injuries.

  1. Injury to the Infrapatellar Branch of the Saphenous Nerve during ACL Reconstruction with Hamstring Tendon Autograft: A Comparison between Oblique and Vertical Incisions

    Directory of Open Access Journals (Sweden)

    Hamid Mousavi

    2018-01-01

    Full Text Available Background: Injury to the infrapatellar branch of the saphenous nerve (IPBSN is common after arthroscopic ACLreconstruction with hamstring tendon autograft, as reported in up to 88% of the cases. Due to close relationshipbetween the IPBSN with pes anserine tendons insertion skin incision may sever IPBSN while harvesting gracillis andsemitendinous tendons. As the IPBSN course at the anterior of knee is oblique, we hypothesized a parallel skin incisionwith nerve passage may decrease nerve injury.Methods: Vertical and oblique incisions were compared in 79 patients in this clinical trial. The sensory loss area andpatients’ complain of numbness were measured at 2 and 8 weeks as well as 6 months after surgery.Results: Both the sensory loss area and patients’ complain of numbness decreased significantly in the oblique incisiongroup (P

  2. Soft tissue reinforcement interposition flaps in hypospadias repair

    Directory of Open Access Journals (Sweden)

    Singh R

    2007-01-01

    Full Text Available Purpose: To discuss the role and mechanism of action of soft tissue reinforcement interposition flaps (STRIFs in hypospadias repairs (reinforced hypospadiac urethroplasties. Materials and Methods: Between 2000-2005, 120 consecutive hypospadiacs (distal 85, mid 20, proximal 15, who underwent primary reinforced urethroplasties employing different types of STRIFs, were retrospectively analyzed. The STRIFs were highly vascular soft tissue pedicled flaps (devoid of epithelium interposed between neo-urethras and the covering skin to reinforce the neo-urethras against fistula formation. The STRIFs were harvested, without much donor site deformity, from: preputial skin, penile skin and scrotal skin by de-epithelialization. Those from Buck′s fascia, corpus spongiosum and tunica vaginalis are STRIFs without epithelium anyway, therefore do not need de-epithelialization. Redo urethroplasties and micropenises were not included. Seven patients were excluded because they had incomplete follow-up. The remaining 113 (distal 84, mid 17, proximal 12 were followed up for nine to 40 months for number, size, location, spontaneous closure and persistence of urethro-cutaneous fistula (UCF, and other complications with regard to the severity of hypospadias, method of neourethral re-construction, types of STRIFs employed and skin cover used. A total of 158 STRIFs and 124 skin covers were used in 113 hypospadiac urethroplasties. Results: The first surgery was curative in 74 (65% of 113 patients. In the remaining 39 (35%, various complications included 12 urethro-cutaneous fistulas (UCFs, 10 urethral strictures, six cases each of penile torsion and meatal stenosis and five cases each of superficial necrosis and poor cosmesis. Of these 39 patients, 25 (64% recovered with conservative treatment and 14 (36% required re-operation, i.e. UCFs and strictures in four cases each and penile torsion, meatal stenosis and dog-ears in two cases each. All the 12 UCFs were single

  3. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model.

    Science.gov (United States)

    Li, Shengkun; Ma, Kui; Li, Hong; Jiang, Jia; Chen, Shiyi

    2016-01-01

    The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET) artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA) is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired with PET were assigned to PET group; the other eight rabbits repaired with PET along with injection of HE were assigned to HA-PET group. All rabbits were sacrificed at 4 and 8 weeks postoperatively for biomechanical and histological examination. The HA-PET group revealed higher biomechanical property compared with the PET group. Histologically, more collagen tissues grew into the HA-PET group compared with PET group. In conclusion, application of sodium hyaluronate can improve the healing of Achilles tendon reconstruction with polyethylene terephthalate artificial ligament.

  4. Iliopsoas Tendon Reformation after Psoas Tendon Release

    Directory of Open Access Journals (Sweden)

    K. Garala

    2013-01-01

    Full Text Available Internal snapping hip syndrome, or psoas tendonitis, is a recognised cause of nonarthritic hip pain. The majority of patients are treated conservatively; however, occasionally patients require surgical intervention. The two surgical options for iliopsoas tendinopathy are step lengthening of the iliopsoas tendon or releasing the tendon at the lesser trochanter. Although unusual, refractory snapping usually occurs soon after tenotomy. We report a case of a 47-year-old active female with internal snapping and pain following an open psoas tenotomy. Postoperatively she was symptom free for 13 years. An MRI arthrogram revealed reformation of a pseudo iliopsoas tendon reinserting into the lesser trochanter. The pain and snapping resolved after repeat iliopsoas tendon release. Reformation of tendons is an uncommon sequela of tenotomies. However the lack of long-term studies makes it difficult to calculate prevalence rates. Tendon reformation should be included in the differential diagnosis of failed tenotomy procedures after a period of symptom relief.

  5. Variation in the insertion of the palmaris longus tendon

    Science.gov (United States)

    Sunil, Vinutha; Rajanna, Shubha; Gitanjali; Kadaba, Jayanthi

    2015-01-01

    The palmaris longus is harvested as a tendon graft in various surgical procedures. We herein report the variations in the insertion of the palmaris longus tendon. During a routine dissection, a rare variation in the insertion of the palmaris longus tendon was observed. In the left forearm, the palmaris longus tendon bifurcated, while in the right forearm, the palmaris longus tendon trifurcated, giving rise to an accessory muscle, which passed superficial to the ulnar artery and ulnar nerve. The accessory muscle was supplied by a deep branch of the ulnar nerve, and the ulnar artery was observed to be tortuous. During reconstructive surgeries, surgeons should bear in mind the accessory muscle. Also, since the palmaris longus muscle provides a very useful graft in tendon surgery, every surgeon should be aware of the variations in the insertion of the palmaris longus tendon. PMID:25640108

  6. Total esophagogastrectomy plus extended lymphadenectomy with transverse colon interposition: A treatment for extensive esophagogastric junction cancer

    OpenAIRE

    Ceroni, Marco; Norero, Enrique; Henríquez, Juan Pablo; Viñuela, Eduardo; Briceño, Eduardo; Martínez, Cristian; Aguayo, Gloria; Araos, Fernando; González, Paulina; Díaz, Alfonso; Caracci, Mario

    2015-01-01

    AIM: To review the post-operative morbidity and mortality of total esophagogastrectomy (TEG) with second barrier lymphadenectomy (D2) with interposition of a transverse colon and to determine the oncological outcomes of TEG D2 with interposition of a transverse colon.

  7. Glenohumeral kinematics after soft tissue interposition graft and glenoid reaming: A cadaveric study

    Directory of Open Access Journals (Sweden)

    Nickolas G Garbis

    2016-01-01

    Conclusion: Glenohumeral contact pressure is significantly improved with interposition of allograft at time zero compared to an arthritic state. Our findings suggest that concentric reaming did not differ from the arthritic model when compared to normal. These findings favor the use of allograft for interposition as a potential treatment option in patients with glenoid wear.

  8. Articular Cartilage Increases Transition Zone Regeneration in Bone-tendon Junction Healing

    Science.gov (United States)

    Qin, Ling; Lee, Kwong Man; Leung, Kwok Sui

    2008-01-01

    The fibrocartilage transition zone in the direct bone-tendon junction reduces stress concentration and protects the junction from failure. Unfortunately, bone-tendon junctions often heal without fibrocartilage transition zone regeneration. We hypothesized articular cartilage grafts could increase fibrocartilage transition zone regeneration. Using a goat partial patellectomy repair model, autologous articular cartilage was harvested from the excised distal third patella and interposed between the residual proximal two-thirds bone fragment and tendon during repair in 36 knees. We evaluated fibrocartilage transition zone regeneration, bone formation, and mechanical strength after repair at 6, 12, and 24 weeks and compared them with direct repair. Autologous articular cartilage interposition resulted in more fibrocartilage transition zone regeneration (69.10% ± 14.11% [mean ± standard deviation] versus 8.67% ± 7.01% at 24 weeks) than direct repair at all times. There was no difference in the amount of bone formation and mechanical strength achieved. Autologous articular cartilage interposition increases fibrocartilage transition zone regeneration in bone-tendon junction healing, but additional research is required to ascertain the mechanism of stimulation and to establish the clinical applicability. PMID:18987921

  9. Early integration of a bone plug in the femoral tunnel in rectangular tunnel ACL reconstruction with a bone-patellar tendon-bone graft: a prospective computed tomography analysis.

    Science.gov (United States)

    Suzuki, Tomoyuki; Shino, Konsei; Nakagawa, Shigeto; Nakata, Ken; Iwahashi, Takehiko; Kinugasa, Kazutaka; Otsubo, Hidenori; Yamashita, Toshihiko

    2011-12-01

    The purpose of this prospective study was to evaluate how early the bone plug was integrated into the rectangular femoral tunnel after anatomical ACL reconstruction using a bone-patellar tendon-bone (BTB) graft via a rectangular tunnel (RT BTB ACL-R). Twenty consecutive patients who had undergone the reconstruction procedure were evaluated by CT scans at 4 and 8 weeks postoperatively. In each scan, 30 slices for multiplanar reconstruction were collected parallel to the long axis of the parallelepiped femoral tunnel and perpendicular to the tendinous plane of the bone plug. Each slice was classified as "complete," indicating no visible gap between the plug and the tunnel wall or trabecular continuity or "incomplete," showing a visible gap. Bone plug-tunnel integration was evaluated as "excellent," "good," "fair," or "poor" for >20, 11-20, 5-10, and values at the anterior interface between the bone plug and the tunnel wall were also measured on both scans. The mean changes in CT value at 8 weeks were significantly lower than those at 4 weeks. This study shows that bone plug-femoral tunnel integration was almost complete by 8 weeks after surgery using RT BTB ACL-R.

  10. Semitendinosus Tendon for Solitary Use in Anterior Cruciate ...

    African Journals Online (AJOL)

    The ANNALS of AFRICAN SURGERY | www.annalsofafricansurgery.com. The ANNALS of ... knee instability. Tendon allografts and autografts have been used successfully to reconstruct a torn. ACL. However, allografts have been associated with a higher rate of failure .... Semitendinosus Tendon to Prevent a. Postoperative ...

  11. Vertical augmentation of the posterior atrophic mandible by interpositional grafts in a split-mouth design: a human tomography evaluation pilot study.

    Science.gov (United States)

    Domingues, Eduardo Pinheiro; Ribeiro, Rafael Fernandes; Horta, Martinho Campolina Rebello; Manzi, Flávio Ricardo; Côsso, Maurício Greco; Zenóbio, Elton Gonçalves

    2017-10-01

    Using computed tomography, to compare vertical and volumetric bone augmentation after interposition grafting with bovine bone mineral matrix (GEISTLICH BIO-OSS ® ) or hydroxyapatite/tricalcium phosphate (STRAUMANN ® BONECERAMIC) for atrophic posterior mandible reconstruction through segmental osteotomy. Seven patients received interposition grafts in the posterior mandible for implant rehabilitation. The computed tomography cone beam images were analysed with OsiriX Imaging Software 6.5 (Pixmeo Geneva, Switzerland) in the pre-surgical period (T0), at 15 days post-surgery (T1) and at 180 days post-surgery (T2). The tomographic analysis was performed by a single trained and calibrated radiologist. Descriptive statistics and nonparametric methods were used to analyse the data. There was a significant difference in vertical and volume augmentation with both biomaterials using the technique (P  0.05) in volume change of the graft, bone volume augmentation, or augmentation of the maximum linear vertical distance between the two analysed biomaterials. The GEISTLICH BIO-OSS ® and STRAUMANN ® BONECERAMIC interposition grafts exhibited similar and sufficient dimensional stability and volume gain for short implants in the atrophic posterior mandible. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Treatment of giant and large fusiform middle cerebral artery aneurysms with excision and interposition radial artery graft in a 4-year-old child: case report.

    Science.gov (United States)

    Mrak, Goran; Paladino, Josip; Stambolija, Vasilije; Nemir, Jakob; Sekhar, Laligam N

    2014-03-01

    We report an unusual case of complex giant and large fusiform aneurysms not amenable for clipping or coiling in a 4-year-old child managed with aneurysm resection and radial artery interposition graft. A 4-year-old child presented with repeated severe headache and vomiting. Computed tomography, magnetic resonance imaging, and magnetic resonance angiography and digital subtraction angiography showed a giant fusiform aneurysm on the right middle cerebral artery (MCA). Because of the complex shape, endovascular treatment or clip reconstruction was not possible, and a bypass procedure was planned. Right frontotemporal craniotomy and orbitotomy was performed. Two aneurysms involving the M1 segment of the MCA were found in line, 1 giant, and the other large in size. The aneurysms were resected and treated with short radial artery interposition graft, which was narrower than the proximal or distal MCA. The child recovered normally, and the bypass was patent after 1 year. Large fusiform MCA aneurysms may be difficult to treat, but there are treatment options that include a bypass procedure. Resection and short interposition radial artery graft is an excellent but rare treatment option in a very young child. This was a very successful treatment in this child.

  13. Initial experience with visualizing hand and foot tendons by dual-energy computed tomography.

    Science.gov (United States)

    Deng, Kai; Sun, Cong; Liu, Cheng; Ma, Rui

    2009-01-01

    To assess the feasibility of visualizing hand and foot tendons by dual-energy computed tomography (CT). Twenty patients who suffered from hand or feet pains were scanned on dual-source CT (Definition, Forchheim, Germany) with dual-energy mode at tube voltages of 140 and 80 kV and a corresponding ratio of 1:4 between tube currents. The reconstructed images were postprocessed by volume rendering techniques (VRT) and multiplanar reconstruction (MPR). All of the suspected lesions were confirmed by surgery or follow-up studies. Twelve patients (total of 24 hands and feet, respectively) were found to be normal and the other eight patients (total of nine hands and feet, respectively) were found abnormal. Dual-energy techniques are very useful in visualizing tendons of the hands and feet, such as flexor pollicis longus tendon, flexor digitorum superficialis/profundus tendon, Achilles tendon, extensor hallucis longus tendon, and extensor digitorum longus tendon, etc. It can depict the whole shape of the tendons and their fixation points clearly. Peroneus longus tendon in the sole of the foot was not displayed very well. The distal ends of metacarpophalangeal joints with extensor digitoium tendon and extensor pollicis longus tendon were poorly shown. The lesions of tendons such as the circuitry, thickening, and adherence were also shown clearly. Dual-energy CT offers a new method to visualize tendons of the hand and foot. It could clearly display both anatomical structures and pathologic changes of hand and foot tendons.

  14. Modified T-Plate Interpositional Arthroplasty for Temporomandibular Joint Ankylosis: A New and Versatile Option

    Directory of Open Access Journals (Sweden)

    Imran Ahmad

    2015-11-01

    Full Text Available BackgroundThis study has been conducted with the aim of evaluating modified T-plate interpositional arthroplasty.MethodsA prospective comparative study in patients admitted with temporomandibular joint ankylosis. Ankylotic temporomandibular joint arthroplasty included condylectomy gap arthroplasty in 7, temporalis muscle flap interpositional arthroplasty in 8, and modified T-plate interpositional arthroplasty in 13 cases. The patients were followed for three years. Collected data were tabulated and subjected to Fisher's exact test, chi-square test and probability estimation.ResultsA significant increase in interincisal distance of 32 mm was seen in 12 (92.31% patients in the T-plate interposition group, in 2 (25% cases of the temporalis muscle flap interposition group, and in 1 case (14.28% of the condylectomy group at 12, 24, and 36 months. Re-ankylosis was observed in 1 case (9.69% of the T-plate interposition group, while as it was observed in 4 (50% cases in the temporalis muscle flap interposition group and 4 (57.14% cases in the condylectomy group, and these differences were statistically significant.ConclusionsOur clinical experience with the use of the T-plate over the past 5 years has been encouraging, and our physiotherapy technique is quite simple. Even illiterate parents can assess it easily. Hence, we recommend this easy technique that does not damage the temporalis muscle for the management of temporomandibular joint ankylosis.

  15. Outcome of different facial nerve reconstruction techniques

    OpenAIRE

    Mohamed, Aboshanif; Omi, Eigo; Honda, Kohei; Suzuki, Shinsuke; Ishikawa, Kazuo

    2016-01-01

    Abstract Introduction: There is no technique of facial nerve reconstruction that guarantees facial function recovery up to grade III. Objective: To evaluate the efficacy and safety of different facial nerve reconstruction techniques. Methods: Facial nerve reconstruction was performed in 22 patients (facial nerve interpositional graft in 11 patients and hypoglossal-facial nerve transfer in another 11 patients). All patients had facial function House-Brackmann (HB) grade VI, either caused by...

  16. Tendon allograft sterilized by peracetic acid/ethanol combined with gamma irradiation.

    Science.gov (United States)

    Zhou, Mo; Zhang, Naili; Liu, Xiaoming; Li, Youchen; Zhang, Yumin; Wang, Xusheng; Li, Baoming; Li, Baoxing

    2014-07-01

    Research and clinical applications have demonstrated that the effects of tendon allografts are comparable to those of autografts when reconstructing injured tendons or ligaments, but allograft safety remains problematic. Sterilisation could eliminate or decrease the possibility of disease transmission, but current methods seldom achieve satisfactory sterilisation without affecting the mechanical properties of the tendon. Peracetic acid-ethanol in combination with low-dose gamma irradiation (PE-R) would inactivate potential deleterious microorganisms without affecting mechanical and biocompatible properties of tendon allograft. Controlled laboratory design. HIV, PPV, PRV and BVDV inactivation was evaluated. After verifying viral inactivation, the treated tendon allografts were characterised by optical microscopy, scanning electron microscopy and tensile testing, and the cytocompatibility was assessed with an MTT assay and by subcutaneous implantation. Effective and efficient inactivation of HIV, PPV, PRV and BVDV was observed. Histological structure and ultrastructure were unchanged in the treated tendon allograft, which also exhibited comparable biomechanical properties and good biocompatibility. The preliminary results confirmed our hypothesis and demonstrated that the PE-R tendon allograft has significant potential as an alternative to ligament/tendon reconstruction. Tendon allografts have been extensively used in ligament reconstruction and tendon repair. However, current sterilisation methods have various shortcomings, so PE-R has been proposed. This study suggests that PE-R tendon allograft has great potential as an alternative for ligament/tendon reconstruction. Sterilisation has been a great concern for tendon allografts. However, most sterilisation methods cannot inactivate viruses and bacteria without impairing the mechanical properties of the tendon allograft. Peracetic acid/ethanol with gamma irradiation can effectively inactivate viruses and bacteria

  17. Calcaneal tendon: imaging findings

    International Nuclear Information System (INIS)

    Montandon, Cristiano; Fonseca, Cristiano Rezio; Montandon Junior, Marcelo Eustaquio; Lobo, Leonardo Valadares; Ribeiro, Flavia Aparecida de Souza; Teixeira, Kim-Ir-Sen Santos

    2003-01-01

    We reviewed the radiological and clinical features of 23 patients with calcaneal tendon diseases, who were submitted to ultrasound or magnetic resonance imaging. The objective of this study was to characterize the lesions for a precise diagnosis of calcaneal tendon injuries. A wide range of calcaneal tendon diseases include degenerative lesions, inflammation of the peritendinous tissue such as peritendinitis and bursitis, and rupture. Imaging methods are essential in the diagnosis, treatment and follow-up of calcaneal tendon diseases. (author)

  18. Tendon Transfer Surgery

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... DESCRIPTION The tendon is the strong cord at either end of a muscle that is attached to bone. Tendons , combined with ...

  19. Tendon surveillance requirements - average tendon force

    International Nuclear Information System (INIS)

    Fulton, J.F.

    1982-01-01

    Proposed Rev. 3 to USNRC Reg. Guide 1.35 discusses the need for comparing, for individual tendons, the measured and predicted lift-off forces. Such a comparison is intended to detect any abnormal tendon force loss which might occur. Recognizing that there are uncertainties in the prediction of tendon losses, proposed Guide 1.35.1 has allowed specific tolerances on the fundamental losses. Thus, the lift-off force acceptance criteria for individual tendons appearing in Reg. Guide 1.35, Proposed Rev. 3, is stated relative to a lower bound predicted tendon force, which is obtained using the 'plus' tolerances on the fundamental losses. There is an additional acceptance criterion for the lift-off forces which is not specifically addressed in these two Reg. Guides; however, it is included in a proposed Subsection IWX to ASME Code Section XI. This criterion is based on the overriding requirement that the magnitude of prestress in the containment structure be sufficeint to meet the minimum prestress design requirements. This design requirement can be expressed as an average tendon force for each group of vertical hoop, or dome tendons. For the purpose of comparing the actual tendon forces with the required average tendon force, the lift-off forces measured for a sample of tendons within each group can be averaged to construct the average force for the entire group. However, the individual lift-off forces must be 'corrected' (normalized) prior to obtaining the sample average. This paper derives the correction factor to be used for this purpose. (orig./RW)

  20. A Case Report of Ridge Augmentation using Onlay Interpositional Graft: An Approach to Improve Prosthetic Prognosis of a Deficit Ridge

    Directory of Open Access Journals (Sweden)

    Devanand Shetty

    2014-01-01

    Full Text Available Background: Periodontal therapy has developed beyond the scope of the treatment of periodontal pathoses. Periodontal plastic surgery consists of the reconstructive procedures designed to enhance the both function and esthetics. Deficient ridges pose a severe problem to the restorative dentist in restoring the natural form, function and esthetics of the prosthesis replacing the natural dentition. Depending upon the severity, location of these defects and the prosthetic option chosen, hard and soft tissue ridge augmentation or non-surgical approach or a combination may help to address them. The present clinical report describes a soft tissue ridge augmentation of a localized ridge defect in maxillary aesthetic region using onlay interpositional graft followed by fixed partial denture.

  1. FIBRILLINS IN TENDON

    Directory of Open Access Journals (Sweden)

    Betti Giusti

    2016-10-01

    Full Text Available Tendons among connective tissue, mainly collagen, contain also elastic fibres made of fibrillin 1, fibrillin 2 and elastin that are broadly distributed in tendons and represent 1-2% of the dried mass of the tendon. Only in the last years, studies on structure and function of elastic fibres in tendons have been performed. Aim of this review is to revise data on the organization of elastic fibres in tendons, in particular fibrillin structure and function, and on the clinical manifestations associated to alterations of elastic fibres in tendons. Indeed, microfibrils may contribute to tendon mechanics; therefore, their alterations may cause joint hypermobility and contractures which have been found to be clinical features in patients with Marfan syndrome and Beals syndrome. The two diseases are caused by mutations in genes FBN1 and FBN2 encoding fibrillin 1 and fibrillin 2, respectively.

  2. Mini-open reconstruction of lateral collateral ligaments of ankle with partial tendon of its peroneus brevis%小切口取部分腓骨短肌腱重建踝关节外侧副韧带

    Institute of Scientific and Technical Information of China (English)

    陈前博; 唐康来; 吴雪晖; 徐格; 谭晓康; 周兵华; 周运平; 许建中

    2008-01-01

    Objective To describe a new technique with mini-open reconstruction of lateral ligaments of ankle with partial tendon of its peroneus brevis and evaluate its effect in treatment of chronic lateral ankle instability. Methods A total of 11 cases of chronic lateral ankle instability;at mean age of 27.6 years(16-42 years),were treated with mini-open reconstruction of the lateral ligaments of the ankle with partial tendon of its peroneus brevis.The mean delay between the initial episode of ankle sprain and the surgery was 10.3 months(4-32 months).Postoperatively,all cases were examined with MRI,stress X-rays and comparative stability of bilateral ankle inspection at clinical follow-up.The function of the ankle were evaluated bv American Orthopaedic Foot & Ankle Society (AOFAS)score and ankle-hind foot scale. Results The average duration of follow-up was 17.5 months(12-37 months).The mean AOFAS ankle-hindfoot score was 88.3 points(72-96 points)at the time of the latest follow-up,including excellent result in 6 cases(55%),good in 4(36%)and fair in 1(9%).MRI results showed that the ruptured lateral collateral ligaments of the ankle were repaired and remodeled very well in all patients.There was no recurrence of the ankle instability or other complications. Conclusion Mini-open reconstruction of the lateral ligaments of ankle with partial tendon of its peroneus brevis is safe and effective for treatment of chronic lateral ankle instability.%目的 介绍小切口取部分腓骨短肌腱解剖重建外侧副韧带治疗慢性踝关节外侧不稳的疗效.方法 11例慢性踝关节外侧不稳患者接受小切口取部分腓骨短肌腱解剖重建踝关节外侧副韧带的手术治疗,年龄16~42岁,平均27.6岁.术前病程4~32个月,平均10.3个月.术后定期行双侧踝关节对比稳定检查、应力位X线片及MRI检查,并按美国足踝外科协会(AOFAS)踝-后足功能评分表进行功能评分.结果 11例患者术后平均随访17.5个月(12~37

  3. Intra-articular membranous interposition detected by MRI in developmental dysplasia of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, W.; Itoi, Eiji; Sato, Kozo [Akita Univ. (Japan). Dept. of Orthopedic Surgery

    2000-12-01

    Intra-articular membranous interposition was detected by MRI in the hip joint with residual subluxation of a girl aged 5 years 10 months. This structure, which had low signal intensity on both T1- and T2-weighted images, separated the femoral head from the acetabulum. Histological examination revealed chondrometaplasia, which suggested that this interposition might be transformed to a surface cartilaginous tissue of the secondary acetabulum often observed in residual subluxation of the hip. (orig.)

  4. Tensile strength comparison between peroneus longus and hamstring tendons: A biomechanical study

    Directory of Open Access Journals (Sweden)

    Rudy

    2017-01-01

    Conclusion: The tensile strength of the peroneus longus tendon, which is similar to that of hamstring, gives information that both have the same biomechanic properties. Peroneus longus should not be used as a first option in ACL reconstruction, but may be used as an alternative donor in cases involving multiple instability that require more tendon donors in the reconstruction.

  5. COMPARATIVE STUDY OF CLINICAL OUTCOME OF ARTHROSCOPIC ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION BONE PATELLAR TENDON BONE GRAFT V/S HAMSTRING GRAFT

    Directory of Open Access Journals (Sweden)

    Priyank

    2015-08-01

    fulfilling the predetermined inclusion and exclusion criteria were included in the study. STATISTICAL METHODS : Intergroup comparison was analysed by K - Independent sample t test. Intragroup comparison was analysed by Paired t - test. RESULTS : Patients were divided into two groups and treated with using Bone - patellar tendon - bone graft and Hamstring graft respectively. Mean age group of patients was 29.16 yrs. (range 16 - 51yrs and 30.88 yrs. (range 19 - 48yrs in group A and B respectively we found the incidence of ACL injury in 15 - 44 years age group to be greater than twice the general population. A mean delay in surgery of 4.66 months (range 2 - 12 months since the time of injury in group A and 4.46 months (range 2 - 7 months in group B was observed. Subjective IKDC evaluation was done at the end of 12 months. Ther e was no difference in both the groups in the terms of effusion, passive motion, knee compartment findings, ligament examination, X - ray findings. Functional test and IKDC grade of both the groups showed statistically very highly significant improvement. Ho wever, there was statistically very high Harvest site pathology in group A. CONCLUSION : We found that there is statistically no significant difference in the overall clinical outcome between hamstring autograft with transfix and bone - patellar tendon bone autograft with interference screw except that the patellar tendon group had a greater tendency of having donor site morbidity compared to the hamstring tendon group.

  6. Total Ossicular Replacement Prosthesis: A New Fat Interposition Technique

    Directory of Open Access Journals (Sweden)

    Issam Saliba

    2018-01-01

    Full Text Available Objective: To compare audiometric results between the standard total ossicular replacement prosthesis (TORP-S and a new fat interposition total ossicular replacement prosthesis (TORP-F in pediatric and adult patients and to assess the complication and the undesirable outcome. Study design: This is a retrospective study. Methods: This study included 104 patients who had undergone titanium implants with TORP-F and 54 patients who had undergone the procedure with TORP-S between 2008 and 2013 in our tertiary care centers. The new technique consists of interposing a fat graft between the 4 legs of the universal titanium prosthesis (Medtronic Xomed Inc, Jacksonville, FL, USA to provide a more stable TORP in the ovale window niche. Normally, this prosthesis is designed to fit on the stapes’ head as a partial ossicular replacement prosthesis. Results: The postoperative air-bone gap less than 25 dB for the combined cohort was 69.2% and 41.7% for the TORP-F and the TORP-S groups, respectively. The mean follow-up was 17 months postoperatively. By stratifying data, the pediatric cohort shows 56.5% in the TORP-F group (n = 52 compared with 40% in the TORP-S group (n = 29. However, the adult cohort shows 79.3% in the TORP-F group (n = 52 compared with 43.75% in the TORP-S group (n = 25. These improvements in hearing were statistically significant. There were no statistically significant differences in the speech discrimination scores. The only undesirable outcome that was statistically different between the 2 groups was the prosthesis displacement: 7% in the TORP-F group compared with 19% in the TORP-S group ( P  = .03. Conclusions: The interposition of a fat graft between the legs of the titanium implants (TORP-F provides superior hearing results compared with a standard procedure (TORP-S in pediatric and adult populations because of its better stability in the oval window niche.

  7. Total Ossicular Replacement Prosthesis: A New Fat Interposition Technique.

    Science.gov (United States)

    Saliba, Issam; Sabbah, Valérie; Poirier, Jackie Bibeau

    2018-01-01

    To compare audiometric results between the standard total ossicular replacement prosthesis (TORP-S) and a new fat interposition total ossicular replacement prosthesis (TORP-F) in pediatric and adult patients and to assess the complication and the undesirable outcome. This is a retrospective study. This study included 104 patients who had undergone titanium implants with TORP-F and 54 patients who had undergone the procedure with TORP-S between 2008 and 2013 in our tertiary care centers. The new technique consists of interposing a fat graft between the 4 legs of the universal titanium prosthesis (Medtronic Xomed Inc, Jacksonville, FL, USA) to provide a more stable TORP in the ovale window niche. Normally, this prosthesis is designed to fit on the stapes' head as a partial ossicular replacement prosthesis. The postoperative air-bone gap less than 25 dB for the combined cohort was 69.2% and 41.7% for the TORP-F and the TORP-S groups, respectively. The mean follow-up was 17 months postoperatively. By stratifying data, the pediatric cohort shows 56.5% in the TORP-F group (n = 52) compared with 40% in the TORP-S group (n = 29). However, the adult cohort shows 79.3% in the TORP-F group (n = 52) compared with 43.75% in the TORP-S group (n = 25). These improvements in hearing were statistically significant. There were no statistically significant differences in the speech discrimination scores. The only undesirable outcome that was statistically different between the 2 groups was the prosthesis displacement: 7% in the TORP-F group compared with 19% in the TORP-S group ( P  = .03). The interposition of a fat graft between the legs of the titanium implants (TORP-F) provides superior hearing results compared with a standard procedure (TORP-S) in pediatric and adult populations because of its better stability in the oval window niche.

  8. Achilles tendon and sports

    International Nuclear Information System (INIS)

    Ulreich, N.; Kainberger, F.; Huber, W.; Nehrer, S.

    2002-01-01

    Because of the rising popularity of recreational sports activities achillodynia is an often associated symptom with running, soccer and athletics. Therefore radiologist are frequently asked to image this tendon. The origin of the damage of the Achilles tendon is explained by numerous hypothesis, mainly a decreased perfusion and a mechanical irritation that lead to degeneration of the tendon. High-resolution technics such as sonography and magnetic resonance imaging show alterations in the structure of the tendon which can be graduated and classified. Manifestations like tendinosis, achillobursitis, rupture and Haglunds disease can summarized as the tendon overuse syndrom. A rupture of a tendon is mostly the result of a degeneration of the collagenfibres. The task of the radiologist is to acquire the intrinsic factors for a potential rupture. (orig.) [de

  9. Reconstrucción y restauración de la rotura aguda del tendón rotuliano con aumento del tendon semitendinoso preservando su inserción distal. Reporte de un caso.[Reconstruction and repair of acute patellar tendon ruptures with semitendinosus autograft].

    Directory of Open Access Journals (Sweden)

    Víctor Andres Ciccarello

    2016-11-01

    Full Text Available Se presenta un caso de ruptura aguda de tendon rotuliano con mala calidad de tejido remanente , en la que se realiza una tecnica de restauración y aumentación con injerto del tendon semitendinoso ipsilateral , preservando su inseríón distal.

  10. Specialisation of extracellular matrix for function in tendons and ligaments

    Science.gov (United States)

    Birch, Helen L.; Thorpe, Chavaunne T.; Rumian, Adam P.

    2013-01-01

    Summary Tendons and ligaments are similar structures in terms of their composition, organisation and mechanical properties. The distinction between them stems from their anatomical location; tendons form a link between muscle and bone while ligaments link bones to bones. A range of overlapping functions can be assigned to tendon and ligaments and each structure has specific mechanical properties which appear to be suited for particular in vivo function. The extracellular matrix in tendon and ligament varies in accordance with function, providing appropriate mechanical properties. The most useful framework in which to consider extracellular matrix differences therefore is that of function rather than anatomical location. In this review we discuss what is known about the relationship between functional requirements, structural properties from molecular to gross level, cellular gene expression and matrix turnover. The relevance of this information is considered by reviewing clinical aspects of tendon and ligament repair and reconstructive procedures. PMID:23885341

  11. Containment structure tendon investigation

    International Nuclear Information System (INIS)

    Fulton, J.F.; Murray, K.H.

    1983-01-01

    The paper describes an investigation into the possible causes of lower-than-predicted tendon forces which were measured during past tendon surveillances for a concrete containment. The containment is post tensioned by vertical tendons which are anchored into a rock foundation. The tendons were originally stressed in 1969, and lift-off tests were performed on six occasions subsequent to this date over a period of 11 years. The tendon forces measured in these tests were generally lower than predicted, and by 1979 the prestress level in the containment was only marginally above the design requirement. The tendons were retensioned in 1980, and by this time an investigation into the possible causes was underway. Potential causes investigated include the rock anchors and surrounding rock, elastomeric pad creep, wire stresses, thermal effects, stressing equipment and lift-off procedures, and wire stress relaxation. The investigation activities included stress relaxation testing of wires pulled from actual tendons. The stress relaxation test program included wire specimens at several different temperature and initial stress levels and the effect of a varying temperature history on the stress relaxation property of the wires. For purpose of future force predictions of the retensioned tendons, the test program included tests to determine the effect on stress relaxation due to restressing the wires after they had relaxed for 1000 hours and 10,000 hours. (orig./GL)

  12. Extensor Tendon Injuries

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Extensor Tendon Injuries Email to a friend * required ...

  13. Sex Hormones and Tendon

    DEFF Research Database (Denmark)

    Hansen, Mette; Kjaer, Michael

    2016-01-01

    The risk of overuse and traumatic tendon and ligament injuries differ between women and men. Part of this gender difference in injury risk is probably explained by sex hormonal differences which are specifically distinct during the sexual maturation in the teenage years and during young adulthood....... The effects of the separate sex hormones are not fully elucidated. However, in women, the presence of estrogen in contrast to very low estrogen levels may be beneficial during regular loading of the tissue or during recovering after an injury, as estrogen can enhance tendon collagen synthesis rate. Yet...... has also been linked to a reduced responsiveness to relaxin. The present chapter will focus on sex difference in tendon injury risk, tendon morphology and tendon collagen turnover, but also on the specific effects of estrogen and androgens....

  14. Inferior tendon graft to bone tunnel healing at the tibia compared to that at the femur after anterior cruciate ligament reconstruction

    International Nuclear Information System (INIS)

    Lui, P.P.Y.; Ho, G.; Shum, W.T.; Lee, Y.W.; Ho, P.Y.; Lo, W.N.; Lo, C.K.

    2010-01-01

    Tunnel widening after anterior cruciate ligament (ACL) reconstruction (ACLR) is commonly reported without a clear understanding of the mechanism. This study aimed to quantify the spatiotemporal change of the newly formed bone mass, bone tunnel diameter, and area along both bone tunnels using micro-computed tomography (μCT) and correlated the result with histology. ACLR was performed in 24 rabbits. At baseline and weeks 2, 6, and 12, the juxta-articular, middle, and exit segments of both tunnels were harvested for μCT and histological evaluation. μCT and histology revealed significant bone tunnel and graft-bone tunnel healing, respectively, only at week 6 after reconstruction. Despite this, the mean tunnel diameter and area remained relatively unchanged with time. The newly formed bone mass [new bone volume/total bone volume (BV/TV) ratio] and its bone mineral density (BMD) were both higher, whereas the mean tunnel diameter and area were significantly smaller at the femoral tunnel compared to those at the tibial tunnel at weeks 6 and 12 and at week 12, respectively. These were consistent with histological findings, which showed inferior graft remodeling and integration at the tibial tunnel at weeks 6 and 12. The BV/TV increased, whereas the mean tunnel diameter and area decreased toward the exit segment of both tunnels. However, whereas better histological healing occurred at the femoral exit segment, poorer graft remodeling and Sharpey's fiber formation occurred at the tibial exit segment. Poor healing was observed during the initial 6 weeks, particularly that of the tibia, after ACLR. Bone resorption was rapid during healing, resulting in unchanged tunnel diameter and area with time. (author)

  15. Reconstructed anterior cruciate ligaments using patellar tendon ligament grafts: diagnostic value of contrast-enhanced MRI in a 2-year follow-up regimen

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Schmitt, J.; Lubrich, J.; Hochmuth, K.; Diebold, T. [Dept. of Diagnostic and Interventional Radiology, Frankfurt Univ. (Germany); Del Tredici, K. [Dept. of Clinical Neuroanatomy, Frankfurt Univ. (Germany); Suedkamp, N. [Dept. of Traumatology and Orthopedics, Humboldt University, Berlin (Germany)

    2001-08-01

    We analyzed prospectively the diagnostic efficacy of contrast-enhanced MRI following anterior cruciate neoligament (ACL) reconstruction. One hundred fifty-six MR examinations were performed 2, 12, 52, 76, and 104 weeks post-operatively on 68 patients with ACL transplants. Sagittal, parasagittal, and coronal images using unenhanced T1- and T2-weighted spin-echo sequences, and post-contrast images utilizing T1-weighted spin-echo and fat-saturated sequences, were acquired. Results were correlated with those of the pivot shift, Lachman, and a mechanical test. The MR examination criteria included morphological analysis, signal intensity, transplant contrast enhancement, secondary signs (e.g., elongation of normal ligaments), and comparison with clinically standardized test results. Two weeks post-operatively all neoligaments showed homogeneous low signal intensity on T1- and T2-weighted spin-echo sequences indistinguishable from that of normal cruciate or patellar ligaments [contrast-to-noise ratio (C/N) on T1:1.6], with a 9% percentile enhancement. At 12-52 weeks, signal intensity increased (C/N:6.7), with a mean 50% percentile enhancement. The 1-year follow-up allowed no definite assessment of the neoligament's course. At 76 and 104 weeks, significant decrements in signal intensity (C/N:3.0) and ligamentous percentile enhancement (25%) occurred. All patients tested displayed stable transplants 2 years post-operatively. Contrast-enhanced MRI allows accurate evaluation of morphology and function up to 3 months post-operatively and 1-2 years following ACL reconstructive surgery. (orig.)

  16. Glenohumeral interposition of rotator cuff stumps: a rare complication of traumatic rotator cuff tear

    Directory of Open Access Journals (Sweden)

    Paulo Moraes Agnollitto

    2016-02-01

    Full Text Available Abstract The present report describes a case where typical findings of traumatic glenohumeral interposition of rotator cuff stumps were surgically confirmed. This condition is a rare complication of shoulder trauma. Generally, it occurs in high-energy trauma, frequently in association with glenohumeral joint dislocation. Radiography demonstrated increased joint space, internal rotation of the humerus and coracoid process fracture. In addition to the mentioned findings, magnetic resonance imaging showed massive rotator cuff tear with interposition of the supraspinatus, infraspinatus and subscapularis stumps within the glenohumeral joint. Surgical treatment was performed confirming the injury and the rotator cuff stumps interposition. It is important that radiologists and orthopedic surgeons become familiar with this entity which, because of its rarity, might be neglected in cases of shoulder trauma.

  17. Stem Cell Applications in Tendon Disorders: A Clinical Perspective

    Directory of Open Access Journals (Sweden)

    Mark Young

    2012-01-01

    Full Text Available Tendon injuries are a common cause of morbidity and a significant health burden on society. Tendons are structural tissues connecting muscle to bone and are prone to tearing and tendinopathy, an overuse or degenerative condition that is characterized by failed healing and cellular depletion. Current treatments, for tendon tear are conservative, surgical repair or surgical scaffold reconstruction. Tendinopathy is treated by exercises, injection therapies, shock wave treatments or surgical tendon debridement. However, tendons usually heal with fibrosis and scar tissue, which has suboptimal tensile strength and is prone to reinjury, resulting in lifestyle changes with activity restriction. Preclinical studies show that cell therapies have the potential to regenerate rather than repair tendon tissue, a process termed tenogenesis. A number of different cell lines, with varying degrees of differentiation, have being evaluated including stem cells, tendon derived cells and dermal fibroblasts. Even though cellular therapies offer some potential in treating tendon disorders, there have been few published clinical trials to determine the ideal cell source, the number of cells to administer, or the optimal bioscaffold for clinical use.

  18. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model

    Directory of Open Access Journals (Sweden)

    Shengkun Li

    2016-01-01

    Full Text Available The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired with PET were assigned to PET group; the other eight rabbits repaired with PET along with injection of HE were assigned to HA-PET group. All rabbits were sacrificed at 4 and 8 weeks postoperatively for biomechanical and histological examination. The HA-PET group revealed higher biomechanical property compared with the PET group. Histologically, more collagen tissues grew into the HA-PET group compared with PET group. In conclusion, application of sodium hyaluronate can improve the healing of Achilles tendon reconstruction with polyethylene terephthalate artificial ligament.

  19. Achilles tendon healing

    International Nuclear Information System (INIS)

    Dillon, E.H.; Pope, C.F.; Barber, V.; Jokl, P.; Lynch, K.

    1990-01-01

    This paper reports on symptomatic Achilles tendon abnormalities (rupture, tendinitis) evaluated with MR imaging during the healing phase after either surgical or conservative treatment. A total of 21 patients were studied. Fifteen of 21 underwent surgery (13 tendon ruptures) and six were managed conservatively (one rupture). MR studies were obtained before treatment in 11, at 3 months in eight, at 6 months in seven, and at 12 months in 12. The 1.5-T spin-echo and gradient-echo images were correlated with clinical results, planter reflex response times, and calf force measurements. Sequential T2 times were obtained from representative levels in the tendons

  20. The prevalence of tenosynovitis of the interosseous tendons of the hand in patients with rheumatoid arthritis.

    OpenAIRE

    Rowbotham, EL; Freeston, JE; Emery, P; Grainger, AJ

    2015-01-01

    AIM: The aim of this study was to establish the prevalence of tenosynovitis affecting the interosseous tendons of the hand in a rheumatoid arthritis (RA) population and to assess for association with metacarpophalangeal (MCP) joint synovitis, flexor tendon tenosynovitis or ulnar drift. METHODS: Forty-four patients with RA underwent hand MRI along with 20 normal controls. Coronal 3D T1 VIBE sequences pre- and post-contrast were performed and reconstructed. The presence of interosseous tendon t...

  1. Achilles tendon repair

    Science.gov (United States)

    ... your Achilles tendon to point your toes and push off your foot when walking. If your Achilles ... MD, Thompson SR, eds. DeLee and Drez's Orthopaedic Sports Medicine: Principles and Practice . 4th ed. Philadelphia, PA: ...

  2. Achilles Tendon Rupture

    Science.gov (United States)

    ... is a strong fibrous cord that connects the muscles in the back of your calf to your heel bone. If you overstretch your Achilles tendon, it can tear (rupture) completely or just partially. If your Achilles ...

  3. Partial trapeziectomy and interposition of fascia lata allograft in the operative treatment of thumb base osteoarthritis

    NARCIS (Netherlands)

    Spaans, Anne J.; Weijns, Marieke E.; Braakenburg, Assa; Van Minnen, Leo Paul; Mink Van Der Molen, Aebele B.

    2016-01-01

    Aim: The purpose of this retrospective cohort study was to evaluate the results of fascia lata allograft interposition after partial trapeziectomy in patients with symptomatic first carpometacarpal joint osteoarthritis. Methods and results: Twenty-one patients (22 thumbs) with Eaton-Glickel stage II

  4. Extensor Tendon Instability Due to Sagittal Band Injury in a Martial Arts Athlete: A Case Report.

    Science.gov (United States)

    Kochevar, Andrew; Rayan, Ghazi

    2017-03-01

    A Taekwondo participant sustained a hand injury from punching an opponent that resulted in painful instability of the ring finger extensor digitorum communis tendon due to sagittal band damage. His symptoms resolved after reconstructive surgery on the sagittal band (SB) with stabilization of the extensor tendon over the metacarpophalangeal joint.

  5. The prevalence of tenosynovitis of the interosseous tendons of the hand in patients with rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Rowbotham, Emma L. [Leeds Teaching Hospitals NHS Trust, Musculoskeletal Radiology Department, Leeds (United Kingdom); Freeston, Jane E. [Department of Rheumatology, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Emery, Paul [University of Leeds, Arthritis Research UK, Leeds Musculoskeletal Biomedical Research Unit, LTHT Leeds Institute of Rheumatic Musculoskeletal Medicine, Leeds (United Kingdom); Grainger, Andrew J. [Leeds Teaching Hospitals NHS Trust, Musculoskeletal Radiology Department, Leeds (United Kingdom); Chapel Allerton Hospital, NIHR Leeds Musculoskeletal Biomedical Research Unit, Leeds (United Kingdom)

    2016-02-15

    The aim of this study was to establish the prevalence of tenosynovitis affecting the interosseous tendons of the hand in a rheumatoid arthritis (RA) population and to assess for association with metacarpophalangeal (MCP) joint synovitis, flexor tendon tenosynovitis or ulnar drift. Forty-four patients with RA underwent hand MRI along with 20 normal controls. Coronal 3D T1 VIBE sequences pre- and post-contrast were performed and reconstructed. The presence of interosseous tendon tenosynovitis was recorded alongside MCP joint synovitis, flexor tendon tenosynovitis and ulnar drift. Twenty-one (47.7 %) patients with RA showed interosseous tendon tenosynovitis. Fifty-two (14.8 %) interosseous tendons showed tenosynovitis amongst the RA patients. Interosseous tendon tenosynovitis was more commonly seen in association with adjacent MCP joint synovitis (p < 0.001), but nine MCP joints (5.1 %) showed adjacent interosseous tenosynovitis in the absence of joint synovitis. Interosseous tendon tenosynovitis was more frequently seen in fingers which also showed flexor tendon tenosynovitis (p < 0.001) and in patients with ulnar drift of the fingers (p = 0.01). Tenosynovitis of the hand interosseous tendons was found in 47.7 % of patients with RA. In the majority of cases this was adjacent to MCP joint synovitis; however, interosseous tendon tenosynovitis was also seen in isolation. (orig.)

  6. The prevalence of tenosynovitis of the interosseous tendons of the hand in patients with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Rowbotham, Emma L.; Freeston, Jane E.; Emery, Paul; Grainger, Andrew J.

    2016-01-01

    The aim of this study was to establish the prevalence of tenosynovitis affecting the interosseous tendons of the hand in a rheumatoid arthritis (RA) population and to assess for association with metacarpophalangeal (MCP) joint synovitis, flexor tendon tenosynovitis or ulnar drift. Forty-four patients with RA underwent hand MRI along with 20 normal controls. Coronal 3D T1 VIBE sequences pre- and post-contrast were performed and reconstructed. The presence of interosseous tendon tenosynovitis was recorded alongside MCP joint synovitis, flexor tendon tenosynovitis and ulnar drift. Twenty-one (47.7 %) patients with RA showed interosseous tendon tenosynovitis. Fifty-two (14.8 %) interosseous tendons showed tenosynovitis amongst the RA patients. Interosseous tendon tenosynovitis was more commonly seen in association with adjacent MCP joint synovitis (p < 0.001), but nine MCP joints (5.1 %) showed adjacent interosseous tenosynovitis in the absence of joint synovitis. Interosseous tendon tenosynovitis was more frequently seen in fingers which also showed flexor tendon tenosynovitis (p < 0.001) and in patients with ulnar drift of the fingers (p = 0.01). Tenosynovitis of the hand interosseous tendons was found in 47.7 % of patients with RA. In the majority of cases this was adjacent to MCP joint synovitis; however, interosseous tendon tenosynovitis was also seen in isolation. (orig.)

  7. Association between incision technique for hamstring tendon harvest in anterior cruciate ligament reconstruction and the risk of injury to the infra-patellar branch of the saphenous nerve: a meta-analysis.

    Science.gov (United States)

    Grassi, Alberto; Perdisa, Francesco; Samuelsson, Kristian; Svantesson, Eleonor; Romagnoli, Matteo; Raggi, Federico; Gaziano, Teide; Mosca, Massimiliano; Ayeni, Olufemi; Zaffagnini, Stefano

    2018-02-08

    To determine how the incision technique for hamstring tendon (HT) harvest in anterior cruciate ligament (ACL) reconstruction affects the risk of injury to the IPBSN and clinical outcome. A systematic literature search of the MEDLINE/Pubmed, Cochrane Central Register of Controlled Trials (CENTRAL) and EBSCOhost electronic databases and clinicaltrials.gov for unpublished studies was performed to identify comparative studies investigating injury to the IPBSN after HT ACL reconstruction by comparing at least two different incision techniques. Data were extracted for the number of patients with evidence of any neurologic deficit corresponding to injury to the IPBSN, area of sensory deficit, the Lysholm score and patient satisfaction. The mean difference (MD) in study outcome between incision groups was assessed. The relative risk (RR) and the number needed to treat (NNT) were calculated. The Chi-square and Higgins' I 2 tests were applied to test heterogeneity. Data were pooled using a Mantel-Haenszel random-effects model if the statistical heterogeneity was > 50% and a fixed-effects model if the statistical heterogeneity was < 50%. The risk of bias was evaluated according to the Cochrane Database questionnaire and the quality of evidence was graded according to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) guidelines. A total of eight studies (three randomized controlled trials (RCTs) and five comparative studies) were included, of which six compared vertical and oblique incisions, one horizontal and vertical incisions, and one compared all three techniques. HT harvest was performed through a vertical incision in 329 patients, through an oblique incision in 195 patients and through a horizontal incision in 151 patients. Considering the meta-analysis of the RCTs, the performance of a vertical incision significantly increased the risk of causing IPBSN deficiency compared with both oblique and horizontal incision [RR 1.65 (CI 1

  8. Influence of an interpositional spacer on the behaviour of the tibiofemoral joint: a finite element study.

    Science.gov (United States)

    Checa, S; Taylor, M; New, A

    2008-10-01

    Interpositional arthroplasty is considered by many surgeons for the treatment of isolated medial compartment osteoarthritis of the knee. In this procedure, an interpositional spacer is inserted into the medial compartment of the joint with no bone resection and no mechanical fixation. Major problems such as implant dislocation, severe pain or need for revision have been reported post-operatively. In this study, the kinematics of a knee implanted with an interpositional spacer made of either polyurethane or cobalt-chrome during walking, stair ascent and squatting cycles have been predicted and compared to the normal knee using finite element analysis. In addition, articular cartilage stress histories have been examined to obtain distributions of cumulative stress, a measure of the likelihood of articular cartilage degeneration. The insertion of a polyurethane interpositional spacer in the medial side of the knee did not affect knee kinematics as compared to the normal knee, but caused an increase of articular cartilage cumulative contact stress exposures in the medial compartment of the joint. The knee implanted with the Co-Cr spacer exhibited similar trends in knee kinematics, however significantly different ranges of motion were observed during some periods of the activity cycles, specifically during the first half of the walking cycle where lower ranges of motion were predicted. In addition, higher articular cartilage cumulative contact stress exposures were observed in both compartments of the knee. In both cases, cumulative contact stress exposures of the tibial articular cartilage were more affected than those of the femoral articular cartilage. These results suggest implant material as an important parameter in the design phase of interpositional spacers.

  9. [Achilles tendon rupture].

    Science.gov (United States)

    Thermann, H; Hüfner, T; Tscherne, H

    2000-03-01

    The treatment of acute of Achilles tendon rupture experienced a dynamic development in the last ten years. Decisive for this development was the application of MRI and above all the ultrasonography in the diagnostics of the pathological changes and injuries of tendons. The question of rupture morphology as well as different courses of healing could be now evaluated objectively. These advances led consequently to new modalities in treatment concepts and rehabilitation protocols. The decisive input for improvements of the outcome results and particularly the shortening of the rehabilitation period came with introduction of the early functional treatment in contrast to immobilizing plaster treatment. In a prospective randomized study (1987-1989) at the Trauma Dept. of the Hannover Medical School could show no statistical differences comparing functional non-operative with functional operative therapy with a special therapy boot (Variostabil/Adidas). The crucial criteria for therapy selection results from the sonographically measured position of the tendon stumps in plantar flexion (20 degrees). With complete adaptation of the tendons' ends surgical treatment does not achieve better results than non-operative functional treatment in term of tendon healing and functional outcome. Regarding the current therapeutic standards each method has is advantages and disadvantages. Both, the operative and non-operative functional treatment enable a stable tendon healing with a low risk of re-rupture (1-2%). Meanwhile there is consensus for early functional after-treatment of the operated Achilles' tendons. There seems to be a trend towards non-operative functional treatment in cases of adequate sonographical findings, or to minimal invasive surgical techniques.

  10. Mechanoactive scaffold induces tendon remodeling and expression of fibrocartilage markers.

    Science.gov (United States)

    Spalazzi, Jeffrey P; Vyner, Moira C; Jacobs, Matthew T; Moffat, Kristen L; Lu, Helen H

    2008-08-01

    Biological fixation of soft tissue-based grafts for anterior cruciate ligament (ACL) reconstruction poses a major clinical challenge. The ACL integrates with subchondral bone through a fibrocartilage enthesis, which serves to minimize stress concentrations and enables load transfer between two distinct tissue types. Functional integration thus requires the reestablishment of this fibrocartilage interface on reconstructed ACL grafts. We designed and characterized a novel mechanoactive scaffold based on a composite of poly-alpha-hydroxyester nanofibers and sintered microspheres; we then used the scaffold to test the hypothesis that scaffold-induced compression of tendon grafts would result in matrix remodeling and the expression of fibrocartilage interface-related markers. Histology coupled with confocal microscopy and biochemical assays were used to evaluate the effects of scaffold-induced compression on tendon matrix collagen distribution, cellularity, proteoglycan content, and gene expression over a 2-week period. Scaffold contraction resulted in over 15% compression of the patellar tendon graft and upregulated the expression of fibrocartilage-related markers such as Type II collagen, aggrecan, and transforming growth factor-beta3 (TGF-beta3). Additionally, proteoglycan content was higher in the compressed tendon group after 1 day. The data suggest the potential of a mechanoactive scaffold to promote the formation of an anatomic fibrocartilage enthesis on tendon-based ACL reconstruction grafts.

  11. Clinical aspects of tendon healing

    NARCIS (Netherlands)

    J.C.H.M. van der Meulen (Jacques)

    1974-01-01

    textabstractWe know that healing of a tendon wound takes place by an invasion of fibreblasts from the surrounding tissues; the tendon itself has no intrinsic healing capacity. lt was Potenza (1962) who proved that a traumatic suture of the tendons within their sheath is followed by disintegration of

  12. Interpositional Gap Arthroplasty by Versatile Pedicled Temporalis Myofascial Flap in the Management of Temporomandibular Joint Ankylosis- A Case Series Study

    OpenAIRE

    Aneja, Vikas; Raval, Rushik; Bansal, Anupam; Kumawat, Vinod; Kaur, Jasleen; Shaikh, Ahemer Arif

    2016-01-01

    Temporomandibular Joint (TMJ) ankylosis is a situation in which the mandibular condyle is fused to the glenoid fossa by bone or fibrous tissue. The management of TMJ ankylosis has a complicated chore and it is challenging for the maxillofacial surgeon because of technical hitches and high rate of re-ankylosis. Interpositional gap arthroplasty is one of the modalities for its management. A range of inter-positional materials have been used to avert recurrence after gap arthroplasty in TMJ anky...

  13. The effect of ileal interposition surgery on enteroendocrine cell numbers in the UC Davis type 2 diabetes mellitus rat

    DEFF Research Database (Denmark)

    Hansen, Carl Frederik; Vassiliadis, Efstathios; Vrang, Niels

    2014-01-01

    To investigate the short-term effect of ileal interposition (IT) surgery on gut morphology and enteroendocrine cell numbers in the pre-diabetic UC Davis type 2 diabetes mellitus (UCD-T2DM) rat.......To investigate the short-term effect of ileal interposition (IT) surgery on gut morphology and enteroendocrine cell numbers in the pre-diabetic UC Davis type 2 diabetes mellitus (UCD-T2DM) rat....

  14. Interpositional Gap Arthroplasty by Versatile Pedicled Temporalis Myofascial Flap in the Management of Temporomandibular Joint Ankylosis- A Case Series Study.

    Science.gov (United States)

    Aneja, Vikas; Raval, Rushik; Bansal, Anupam; Kumawat, Vinod; Kaur, Jasleen; Shaikh, Ahemer Arif

    2016-10-01

    Temporomandibular Joint (TMJ) ankylosis is a situation in which the mandibular condyle is fused to the glenoid fossa by bone or fibrous tissue. The management of TMJ ankylosis has a complicated chore and it is challenging for the maxillofacial surgeon because of technical hitches and high rate of re-ankylosis. Interpositional gap arthroplasty is one of the modalities for its management. A range of inter-positional materials have been used to avert recurrence after gap arthroplasty in TMJ ankylosis. The aim of this series was to evaluate the effectiveness of the temporomyofacial flap in the treatment of TMJ ankylosis as an interpositional gap arthroplasty. A total of 10 cases with unilateral TMJ ankylosis were treated by interpositional gap arthroplasty by pedicled temporalis myofacial flap and evaluated with a follow-up of 6 months to 5 years (Mean 3.3 years) for the functional stability of TMJ. All the patients were successfully treated. There were no signs of recurrence in any patients up to last follow up visit. The result showed that temporalis myofascial flap is a preferable choice for inter-positional gap arthroplasty which proves its versatility as an inter-positional material.

  15. [Experimental study on co-culture of human fibroblasts on decellularized Achilles tendon].

    Science.gov (United States)

    Wang, Zhibing; Zhang, Xia; Guo, Xinyu; Qin, Chuan

    2013-07-01

    To investigate the preparation of decellularized Achilles tendons and the effect of co-culture of human fibroblasts on the scaffold so as to provide a scaffold for the tissue engineered ligament reconstruction. Achilles tendons of both hind limbs were harvested from 10 male New Zealand white rabbits (5-month-old; weighing, 4-5 kg). The Achilles tendons were decellularized using trypsin, Triton X-100, and sodium dodecyl sulfate (SDS), and then gross observation, histological examination, and scanning electron microscope (SEM) observation were performed; the human fibroblasts were seeded on the decellularized Achilles tendon, and then cytocompatibility was tested using the cell counting kit 8 method at 1, 3, 5, 7, and 9 days after co-culture. At 4 weeks after co-culture, SEM, HE staining, and biomechanical test were performed for observing cell-scaffold composite, and a comparison was made with before and after decellularization. After decellularization, the tendons had integrated aponeurosis and enlarged volume with soft texture and good toughness; there was no loose connective tissue and tendon cells between tendon bundles, the collagen fibers arranged loosely with three-dimensional network structure and more pores between tendon bundles; and it had good cytocompatibility. At 4 weeks after co-culture, cells migrated into the pores, and three-dimensional network structure disappeared. By biomechanical test, the tensile strength and Young's elastic modulus of the decellularized Achilles tendon group decreased significantly when compared with normal Achilles tendons group and cell-scaffold composite group (P Achilles tendons group and cell-scaffold composite group (P > 0.05). There was no significant difference in elongation at break among 3 groups (P > 0.05). The decellularized Achilles tendon is biocompatible to fibroblasts. It is suit for the scaffold for tissue engineered ligament reconstruction.

  16. Robotic-assisted vesicovaginal fistula repair using an extravesical approach without interposition grafting.

    Science.gov (United States)

    Kelly, Erin; Wu, Maria Y; MacMillan, J Barry

    2018-03-01

    Post-hysterectomy vesicovaginal fistula (VVF) is rare. In addition to conventional abdominal and vaginal approaches, robotic-assisted VVF repairs have recently been described. We present a case of an extravesical, robotic-assisted VVF repair, without placement of an interposition graft performed in a Canadian teaching center. A 51-year-old woman presented with urinary incontinence 5 days after laparoscopic hysterectomy. Computed tomography cystogram, cystoscopy, and methylene blue dye test, confirmed a VVF above the bladder trigone. The patient underwent a robotic-assisted VVF repair 3 months after presentation, without complication. An abdominal, extravesical approach was used. Operative time was 116 min and repeat CT cystogram showed no evidence of persistent. We have demonstrated that a VVF repair, using a robotic-assisted, extravesical approach without interposition graft placement, can be safe, less invasive and have a successful outcome at 1 year of follow-up.

  17. Flexor Tendon Injuries

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... fields From * To * DESCRIPTION The muscles that bend (flex) the fingers are called flexor ...

  18. triceps tendon avulsion

    African Journals Online (AJOL)

    GB

    2014-01-01

    Jan 1, 2014 ... trauma. Systemic causes such as chronic renal failure, steriod use, diabetes mellitus, hyperparathyroidism, rheumatoid arthritis, osteogensis imperfecta and local causes like local steriod injection, olecranon bursitis and attritional changes due to degenerative arthritis are associated with tendon weakening.

  19. Total esophagogastrectomy plus extended lymphadenectomy with transverse colon interposition: A treatment for extensive esophagogastric junction cancer.

    Science.gov (United States)

    Ceroni, Marco; Norero, Enrique; Henríquez, Juan Pablo; Viñuela, Eduardo; Briceño, Eduardo; Martínez, Cristian; Aguayo, Gloria; Araos, Fernando; González, Paulina; Díaz, Alfonso; Caracci, Mario

    2015-10-08

    To review the post-operative morbidity and mortality of total esophagogastrectomy (TEG) with second barrier lymphadenectomy (D2) with interposition of a transverse colon and to determine the oncological outcomes of TEG D2 with interposition of a transverse colon. This study consisted of a retrospective review of patients with a cancer diagnosis who underwent TEG between 1997 and 2013. Demographic data, surgery protocols, complications according to Clavien-Dindo classifications, final pathological reports, oncological follow-ups and causes of death were recorded. We used the TNM 2010 and Japanese classifications for nodal dissection of gastric cancer. We used descriptive statistical analysis and Kaplan-Meier survival curves. A P-value of less than 0.05 was considered statistically significant. The series consisted of 21 patients (80.9% men). The median age was 60 years. The 2 main surgical indications were extensive esophagogastric junction cancers (85.7%) and double cancers (14.2%). The mean total surgery time was 405 min (352-465 min). Interposition of a transverse colon through the posterior mediastinum was used for replacement in all cases. Splenectomy was required in 13 patients (61.9%), distal pancreatectomy was required in 2 patients (9.5%) and resection of the left adrenal gland was required in 1 patient (4.7%). No residual cancer surgery was achieved in 75.1% of patients. A total of 71.4% of patients had a postoperative complication. Respiratory complications were the most frequently observed complication. Postoperative mortality was 5.8%. Median follow-up was 13.4 mo. Surgery specific survival at 5 years of follow-up was 32.8%; for patients with curative surgery, it was 39.5% at 5 years. TEG for cancer with interposition of a transverse colon is a very complex surgery, and it presents high post-operative morbidity and adequate oncological outcomes.

  20. [Free tissue transfers with lengthening of vascular pedicle using interpositional vein grafts. About 10 cases].

    Science.gov (United States)

    Yeo, S; Perrot, P; Duteille, F

    2010-04-01

    The realization of free flaps with lack of reliable vessels nearby the loss of substance is a difficult problem for plastic surgeons. We report 10 cases of free tissue transfers with a one-stage technique lengthening the vascular pedicle of the free flap with interpositional vein grafts. Taking into consideration the good results and the low rate of morbidity, the authors emphasize the use of this technique rather than a two-stage procedure. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  1. A novel technique for distal fingertip replantation: Polypropylene suture guided interpositional vein graft.

    Science.gov (United States)

    Dadaci, Mehmet; Ince, Bilsev; Altuntas, Zeynep; Bitik, Ozan; Uzun, Hakan; Bilgen, Fatma

    2015-05-04

    Despite current advances in microsurgery, fingertip replantation is still controversial, mainly due to its difficulty and cost. The purpose of this study is to describe a new technique of interposition vein graft guided by polypropylene suture in distal fingertip replantation. A total of eight consecutive Tamai zone 1 fingertip replantations performed by the same author were included. All replantations were performed using interposition vein graft guided by polypropylene suture. This technique involved a vein graft of ∼ 2 cm, with appropriate calibration, obtained from the volar part of the forearm and a 2-0 polyprolene suture passed through the interposition vein graft. Then, a polypropylene suture guide carrying the vein graft was inserted into the artery. The anastomosis was easily performed with the aid of 10-0 or 11-0 nylon in a bloodless medium and without encountering the posterior wall problem. Average surgery time was 2.5 hours (range = 2-3 hours). Among eight Tamai zone 1 replantations, six were successful (75%). There were two replantations lost because of arterial failure. This technique may ease fingertip replantations and increase the success rate for Tamai zone 1 injuries.

  2. Presence of Bacteria in Spontaneous Achilles Tendon Ruptures.

    Science.gov (United States)

    Rolf, Christer G; Fu, Sai-Chuen; Hopkins, Chelsea; Luan, Ju; Ip, Margaret; Yung, Shu-Hang; Friman, Göran; Qin, Ling; Chan, Kai-Ming

    2017-07-01

    The structural pathology of Achilles tendon (AT) ruptures resembles tendinopathy, but the causes remain unknown. Recently, a number of diseases were found to be attributed to bacterial infections, resulting in low-grade inflammation and progressive matrix disturbance. The authors speculate that spontaneous AT ruptures may also be influenced by the presence of bacteria. Bacteria are present in ruptured ATs but not in healthy tendons. Cross-sectional study; Level of evidence, 3. Patients with spontaneous AT ruptures and patients undergoing anterior cruciate ligament (ACL) reconstruction were recruited for this study. During AT surgical repair, excised tendinopathic tissue was collected, and healthy tendon samples were obtained as controls from hamstring tendon grafts used in ACL reconstruction. Half of every sample was reserved for DNA extraction and the other half for histology. Polymerase chain reaction (PCR) was conducted using 16S rRNA gene universal primers, and the PCR products were sequenced for the identification of bacterial species. A histological examination was performed to compare tendinopathic changes in the case and control samples. Five of 20 AT rupture samples were positive for the presence of bacterial DNA, while none of the 23 hamstring tendon samples were positive. Sterile operating and experimental conditions and tests on samples, controlling for harvesting and processing procedures, ruled out the chance of postoperative bacterial contamination. The species identified predominantly belonged to the Staphylococcus genus. AT rupture samples exhibited histopathological features characteristic of tendinopathy, and most healthy hamstring tendon samples displayed normal tendon features. There were no apparent differences in histopathology between the bacterial DNA-positive and bacterial DNA-negative AT rupture samples. The authors have demonstrated the presence of bacterial DNA in ruptured AT samples. It may suggest the potential involvement of bacteria

  3. An artificial tendon with durable muscle interface.

    Science.gov (United States)

    Melvin, Alan; Litsky, Alan; Mayerson, Joel; Witte, David; Melvin, David; Juncosa-Melvin, Natalia

    2010-02-01

    A coupling mechanism that can permanently fix a forcefully contracting muscle to a bone anchor or any totally inert prosthesis would meet a serious need in orthopaedics. Our group developed the OrthoCoupler device to satisfy these demands. The objective of this study was to test OrthoCoupler's performance in vitro and in vivo in the goat semitendinosus tendon model. For in vitro evaluation, 40 samples were fatigue-tested, cycling at 10 load levels, n = 4 each. For in vivo evaluation, the semitendinosus tendon was removed bilaterally in eight goats. Left sides were reattached with an OrthoCoupler, and right sides were reattached using the Krackow stitch with #5 braided polyester sutures. Specimens were harvested 60 days postsurgery and assigned for biomechanics and histology. Fatigue strength of the devices in vitro was several times the contractile force of the semitendinosus muscle. The in vivo devices were built equivalent to two of the in vitro devices, providing an additional safety factor. In strength testing at necropsy, suture controls pulled out at 120.5 +/- 68.3 N, whereas each OrthoCoupler was still holding after the muscle tore, remotely, at 298 +/- 111.3 N (mean +/- SD) (p < 0.0003). Muscle tear strength was reached with the fiber-muscle composite produced in healing still soundly intact. This technology may be of value for orthopaedic challenges in oncology, revision arthroplasty, tendon transfer, and sports-injury reconstruction. (c) 2009 Orthopaedic Research Society.

  4. The Role of Bioreactors in Ligament and Tendon Tissue Engineering.

    Science.gov (United States)

    Mace, James; Wheelton, Andy; Khan, Wasim S; Anand, Sanj

    2016-01-01

    Bioreactors are pivotal to the emerging field of tissue engineering. The formation of neotissue from pluripotent cell lineages potentially offers a source of tissue for clinical use without the significant donor site morbidity associated with many contemporary surgical reconstructive procedures. Modern bioreactor design is becoming increasingly complex to provide a both an expandable source of readily available pluripotent cells and to facilitate their controlled differentiation into a clinically applicable ligament or tendon like neotissue. This review presents the need for such a method, challenges in the processes to engineer neotissue and the current designs and results of modern bioreactors in the pursuit of engineered tendon and ligament.

  5. Miscellaneous conditions of tendons, tendon sheaths, and ligaments.

    Science.gov (United States)

    Dyson, S J; Dik, K J

    1995-08-01

    The use of diagnostic ultrasonography has greatly enhances our ability to diagnose injuries of tendons and tendon sheaths that were previously either unrecognized or poorly understood. For may of these injuries, there is currently only a small amount of follow-up data. This article considers injuries of the deep digital flexor tendon and its accessory ligament, the carpal tunnel syndrome soft tissue swellings on the dorsal aspect of the carpus, intertubercular (bicipital) bursitis and bicipital tendinitis, injuries of the gastrocnemius tendon, common calcaneal tendinitis, rupture of peroneus (fibularis tertius) and ligaments injuries of the back.

  6. Effect of repeated freezing-thawing on the Achilles tendon of rabbits.

    Science.gov (United States)

    Chen, Lianxu; Wu, Yanping; Yu, Jiakuo; Jiao, Zhaode; Ao, Yingfang; Yu, Changlong; Wang, Jianquan; Cui, Guoqing

    2011-06-01

    The increased use of allograft tissue in the reconstruction of anterior cruciate ligament has brought more focus to the effect of storage and treatment on allograft. The purpose of this study was to observe the effect of histology and biomechanics on Achilles tendon in rabbits through repeated freezing-thawing before allograft tendon transplantation. Rabbit Achilles tendons were harvested and processed according to the manufacture's protocol of tissue bank, and freezing-thawing was repeated three times (group 1) and ten times (group 2). Those received only one cycle were used as controls. Then, tendons in each group were selected randomly to make for histological observations and biomechanics test. Histological observation showed that the following changes happened as the number of freezing-thawing increased: the arrangement of tendon bundles and collagen fibrils became disordered until ruptured, cells disrupted and apparent gaps appeared between tendon bundle because the formation of ice crystals. There were significant differences between the experimental and control groups in the values of maximum load, energy of maximum load and maximum stress, whereas no significant differences existed in other values such as stiffness, maximum strain, elastic modulus, and energy density. Therefore, repeated freezing-thawing had histological and biomechanical effect on Achilles tendon in rabbits before allograft tendon transplantation. This indicates that cautions should be taken in the repeated freezing-thawing preparation of allograft tendons in clinical application.

  7. Novel methods for tendon investigations

    DEFF Research Database (Denmark)

    Kjær, Michael; Langberg, Henning; Bojsen-Møller, J.

    2008-01-01

    Purpose. Tendon structures have been studied for decades, but over the last decade, methodological development and renewed interest for metabolic, circulatory and tissue protein turnover in tendon tissue has resulted in a rising amount of investigations. Method. This paper will detail the various...... modern investigative techniques available to study tendons. Results. There are a variety of investigative methods available to study the correlations between mechanics and biology in tendons. Conclusion. The available methodologies not only allow for potential insight into physiological...... and pathophysiological mechanisms in tendon tissue, but also, to some extent, allow for more elaborate studies of the intact human tendon. Read More: http://informahealthcare.com/doi/full/10.1080/09638280701785403...

  8. Simultaneous bilateral patellar tendon rupture ?

    OpenAIRE

    Moura, Diogo Lino; Marques, Jos? Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2016-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a s...

  9. Interposition of the posterior cruciate ligament into the medial compartment of the knee joint on coronal magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Su; Yoon, Young Cheol; Park, Ki Jeong; Wang, Joon Ho [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Choe, Bong Keun [Dept. of Preventive Medicine, Kyung Hee University School of Medicine, Seoul (Korea, Republic of)

    2016-04-15

    The purpose of our study was to evaluate the overall prevalence and clinical significance of interposition of the posterior cruciate ligament (PCL) into the medial compartment of the knee joint in coronal magnetic resonance imaging (MRI). We retrospectively reviewed 317 consecutive patients referred for knee MRI at our institution between October 2009 and December 2009. Interposition of the PCL into the medial compartment of the knee joint on proton coronal MRI was evaluated dichotomously (i.e., present or absent). We analyzed the interposition according to its prevalence as well as its relationship with right-left sidedness, gender, age, and disease categories (osteoarthritis, anterior cruciate ligament tear, and medial meniscus tear). Prevalence of interposition of PCL into the medial compartment of the knee joint was 47.0% (149/317). There was no right (50.0%, 83/166) to left (43.7%, 66/151) or male (50.3%, 87/173) to female (43.1%, 62/144) differences in the prevalence. There was no significant association between the prevalence and age, or the disease categories. Interposition of the PCL into the medial compartment of the knee joint is observed in almost half of patients on proton coronal MRI of the knee. Its presence is not associated with any particular factors including knee pathology and may be regarded as a normal MR finding.

  10. Structured white light scanning of rabbit Achilles tendon.

    Science.gov (United States)

    Hayes, Alex; Easton, Katrina; Devanaboyina, Pavan Teja; Wu, Jian-Ping; Kirk, Thomas Brett; Lloyd, David

    2016-11-07

    The cross-sectional area (CSA) of a material is used to calculate stress under load. The mechanical behaviour of soft tissue is of clinical interest in the management of injury; however, measuring CSA of soft tissue is challenging as samples are geometrically irregular and may deform during measurement. This study presents a simple method, using structured light scanning (SLS), to acquire a 3D model of rabbit Achilles tendon in vitro for measuring CSA of a tendon. The Artec Spider™ 3D scanner uses structured light and stereophotogrammetry technologies to acquire shape data and reconstruct a 3D model of an object. In this study, the 3D scanner was integrated with a custom mechanical rig, permitting 360-degree acquisition of the morphology of six New Zealand White rabbit Achilles tendons. The reconstructed 3D model was then used to measure CSA of the tendon. SLS, together with callipers and micro-CT, was used to measure CSA of objects with a regular or complex shape, such as a drill flute and human cervical vertebra, for validating the accuracy and repeatability of the technique. CSA of six tendons was measured with a coefficient of variation of less than 2%. The mean CSA was 9.9±1.0mm 2 , comparable with those reported by other researchers. Scanning of phantoms demonstrated similar results to μCT. The technique developed in this study offers a simple and accurate method for effectively measuring CSA of soft tissue such as tendons. This allows for localised calculation of stress along the length, assisting in the understanding of the function, injury mechanisms and rehabilitation of tissue. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Comparative evaluation of two reconstructive methods following laparoscopic assisted subtotal gastrectomy in dogs

    Directory of Open Access Journals (Sweden)

    Bakhtiari Jalal

    2012-12-01

    Full Text Available Abstract Background Laparoscopic gastrectomy is a new and technically challenging surgical procedure with potential benefit. The objective of this study was to investigate clinical and para-clinical consequences following Roux-en-Y and Jejunal Loop interposition reconstructive techniques for subtotal gastrectomy using laparoscopic assisted surgery. Results Following resection of the stomach attachments through a laparoscopic approach, stomach was removed and reconstruction was performed with either standard Roux-en-Y (n = 5 or Jejunal Loop interposition (n = 5 methods. Weight changes were monitored on a daily basis and blood samples were collected on Days 0, 7 and 21 post surgery. A fecal sample was collected on Day 28 after surgery to evaluate fat content. One month post surgery, positive contrast radiography was conducted at 5, 10, 20, 40, 60 and 90 minutes after oral administration of barium sulfate, to evaluate the postoperative complications. There was a gradual decline in body weight in both experimental groups after surgery (P  0.05. Fecal fat content increased in the Roux-en-Y compared to the Jejunal loop interposition technique (P  0.05. Conclusion Roux-en-Y and Jejunal loop interposition techniques might be considered as suitable approaches for reconstructing gastro-intestinal tract following gastrectomy in dogs. The results of this study warrant further investigation with a larger number of animals.

  12. CT-control of the H-graft interposition mesocaval shunt patency

    Energy Technology Data Exchange (ETDEWEB)

    Partanen, P L.K.; Oksala, I

    1984-02-01

    A method for assessing the patency of the H-graft interposition mesocaval shunts by computerized tomography is described. Five patients with such shunts were examined with a 5.5 second CT scanner. After locating the graft a 50 cc bolus of 76% diatrizoate was injected into a cubital vein and 3-4 scans were executed at a preselected level. A distinct vessel like enhancement appeared if the shunt was open. With dynamic CT-scanning the flow can be demonstrated in graphical form as time-density curves.

  13. Biomechanical and immunohistochemical analysis of high hydrostatic pressure-treated Achilles tendons

    International Nuclear Information System (INIS)

    Diehl, P.; Steinhauser, E.; Gollwitzer, H.; Heister, C.; Schauwecker, J.; Schmitt, M.; Milz, S.; Mittelmeier, W.

    2006-01-01

    Reconstruction of bone defects caused by malignant tumors is carried out in different ways. At present, tumor-bearing bone segments are devitalized mainly by extracorporeal irradiation or autoclaving, but both methods have substantial disadvantages. In this regard, high hydrostatic pressure (HHP) treatment of the bone is a new, advancing technology that has been used in preclinical testing to inactivate normal cells and tumor cells without altering the biomechanical properties of the bone. The aim of this study was to examine the biomechanical and immunohistochemical properties of tendons after exposure to HHP and to evaluate whether preservation of the bony attachment of tendons and ligaments is possible. For this, 19 paired Achilles tendons were harvested from both hindlimbs of 4-month-old pigs. After preparation, the cross-sectional area of each tendon was determined by magnetic resonance imaging (MRI). For each animal, one of the two tendons was taken at random and exposed to a pressure of 300 MPa (n=9) or 600 MPa (n=10). The contralateral tendon served as an untreated control. The biomechanical properties of the tendons remained unchanged with respect to the tested parameters: Young's modulus (MPa) and tensile strength (MPa). This finding is in line with immunohistochemical labeling results, as no difference in the labeling pattern of collagen I and versican was observed when comparing the HHP group (at 600 MPa) to the untreated control group. We anticipate that during orthopedic surgery HHP can serve as a novel, promising methodical approach to inactivate Achilles tendon and bone cells without altering the biomechanical properties of the tendons. This should allow one to preserve the attachment of tendon and ligaments to the devitalized bone and to facilitate functional reconstruction. (author)

  14. Patellar Sleeve Fracture With Ossification of the Patellar Tendon.

    Science.gov (United States)

    Damrow, Derek S; Van Valin, Scott E

    2017-03-01

    Patellar sleeve fractures make up greater than 50% of all patellar fractures. They are essentially only seen in the pediatric population because of the thick periosteum and the distal patellar pole apophysis in this group. These fractures can lead to complications if not treated appropriately and in a timely fashion. Complications of missed or untreated patellar sleeve fractures include patella alta, anterior knee pain, and quadriceps atrophy. These can all result in severe limitations in activity. The authors describe a case of a 16-year-old boy who sustained a patellar sleeve fracture 3 years prior to presentation. On presentation, he had patella alta, diminished strength, 5° of extensor lag, and radiographs that revealed bone formation along the patellar tendon. Despite this, he was able to maintain a high level of activity. This case report explores how the patient could have maintained a high level of activity despite having a patellar sleeve fracture. Also, because of the delayed presentation, the patella was ossified and the quadriceps was retracted, which led to a novel approach to reconstructing his distal extensor mechanism. This approach included a V-Y advancement of the quadriceps tendon and patellar tendon reconstruction using the patient's hamstring tendon (semitendinosus). This technique, combined with physical therapy postoperatively, resulted in his return to varsity high school soccer. To the best of the authors' knowledge, this technique has not been reported for this rare condition. [Orthopedics. 2017; 40(2):e357-e359.]. Copyright 2016, SLACK Incorporated.

  15. In vivo engineering of a functional tendon sheath in a hen model.

    Science.gov (United States)

    Xu, Liang; Cao, Dejun; Liu, Wei; Zhou, Guangdong; Zhang, Wen Jie; Cao, Yilin

    2010-05-01

    Repair of injured tendon sheath remains a major challenge and this study explored the possibility of in vivo reconstruction of a tendon sheath with tendon sheath derived cells and polyglycolic acid (PGA) fibers in a Leghorn hen model. Total 55 Leghorn hens with a 1cm tendon sheath defect created in the left middle toe of each animal were randomly assigned into: (1) experimental group (n=19) that received a cell-PGA construct; (2) scaffold control group (n=18) that received a cell-free PGA scaffold; (3) blank control group (n=18) with the defect untreated. Tendon sheath cells were isolated, in vitro expanded, and seeded onto PGA scaffolds. After in vitro culture for 7 days, the constructs were in vivo implanted to repair the sheath defects. Alcian blue staining confirmed the ability of cultured cells to produce specific matrices containing acidic carboxyl mucopolysaccharide (mainly hyaluronic acid). In addition, the engineered sheath formed a relatively mature structure at 12 weeks post-surgery, which was similar to that of native counterpart, including a smooth inner surface, a well-developed sheath histological structure with a clear space between the tendon and the engineered sheath. More importantly, Work of Flexion assay revealed that the tendons needed less power consumption to glide inside the engineered sheath when compared to the tendons which were surrounded by scar-repaired tissues, indicating that the engineered sheaths had gained the function to a certain extent of preventing tendon adhesion. Taken together, these results suggest that tendon sheaths that are functionally and structurally similar to native sheaths are possible to be engineered in vivo using tendon sheath cells and PGA scaffolds. Copyright 2010 Elsevier Ltd. All rights reserved.

  16. [Successive ruptures of patellar and Achilles tendons. Anabolic steroids in competitive sports].

    Science.gov (United States)

    Isenberg, J; Prokop, A; Skouras, E

    2008-01-01

    Derivatives of testosterone or of 19-nor-testosterone are used as anabolics for the purpose of improving performance although the effect of anabolics is known still to be under discussion. The use of anabolic steroids continues among competitive athletes despite increased controls and increasingly frequent dramatic incidents connected with them. Whereas metabolic dysfunction during anabolic use is well documented, ruptures of the large tendons are rarely reported. Within 18 months, a 29-year-old professional footballer needed surgery for rupture of the patellar tendon and of both Achilles tendons. Carefully directed questioning elicited confirmation that he had taken different anabolic steroids regularly for 3 years with the intention of improving his strength. After each operation anabolic steroids were taken again at a high dosage during early convalescence and training. Minimally invasive surgery and open suturing techniques led to complete union of the Achilles tendons in good time. Training and anabolic use (metenolon 300 mg per week) started early after suturing of the patellar tendon including bone tunnels culminated in histologically confirmed rerupture after 8 weeks. After a ligament reconstruction with a semitendinosus tendon graft with subsequent infection, the tendon and reserve traction apparatus were lost. Repeated warnings of impaired healing if anabolic use was continued had been given without success. In view of the high number of unrecorded cases in competitive and athletic sports, we can assume that the use of anabolic steroids is also of quantitative relevance in the operative treatment of tendon ruptures.

  17. Rupture Following Biceps-to-Triceps Tendon Transfer in Adolescents and Young Adults With Spinal Cord Injury:

    Science.gov (United States)

    Merenda, Lisa A.; Rutter, Laure; Curran, Kimberly; Kozin, Scott H.

    2012-01-01

    Background: Tendon transfer surgery can restore elbow extension in approximately 70% of persons with tetraplegia and often results in antigravity elbow extension strength. However, we have noted an almost 15% rupture/attenuation rate. Objective: This investigation was conducted to analyze potential causes in adolescents/young adults with spinal cord injury (SCI) who experienced tendon rupture or attenuation after biceps-to-triceps transfer. Methods: Medical charts of young adults with SCI who underwent biceps-to-triceps transfer and experienced tendon rupture or attenuation were reviewed. Data collected by retrospective chart review included general demographics, surgical procedure(s), use and duration of antibiotic treatment, time from tendon transfer surgery to rupture/attenuation, and method of diagnosis. Results: Twelve subjects with tetraplegia (mean age, 19 years) who underwent biceps-to-triceps reconstruction with subsequent tendon rupture or attenuation were evaluated. Mean age at time of tendon transfer was 18 years (range, 14-21 years). A fluoroquinolone was prescribed for 42% (n=5) of subjects. Tendon rupture was noted in 67% (n=8), and attenuation was noted in 33% (n=4). Average length of time from surgery to tendon rupture/attenuation was 5.7 months (range, 3-10 months). Conclusion: Potential contributing causes of tendon rupture/attenuation after transfer include surgical technique, rehabilitation, co-contraction of the transfer, poor patient compliance, and medications. In this cohort, 5 subjects were prescribed fluoroquinolones that have a US Food and Drug Administration black box concerning tendon ruptures. Currently, all candidates for upper extremity tendon transfer reconstruction are counseled on the effects of fluoroquinolones and the potential risk for tendon rupture. PMID:23459326

  18. One-stage metatarsal lengthening by allograft interposition: a novel approach for congenital brachymetatarsia.

    Science.gov (United States)

    Giannini, Sandro; Faldini, Cesare; Pagkrati, Stavroula; Miscione, Maria Teresa; Luciani, Deianira

    2010-07-01

    Congenital brachymetatarsia, a shortened metatarsal bone, can be corrected surgically by callus distraction or one-stage lengthening using bone graft. We asked whether one-stage metatarsal lengthening using metatarsal homologous bone graft could improve forefoot function, lead to metatarsal healing, restore metatarsal parabola, and improve cosmetic appearance. We retrospectively reviewed 29 patients (41 feet) in whom we lengthened 50 metatarsals. Surgery consisted of a transverse proximal osteotomy of the metatarsal shaft and interposition of a metatarsal homologous bone graft (average, 13 mm long) fixed with an intramedullary Kirschner wire. Minimum followup was 3 years (mean, 5 years; range, 3-11 years). Bone union was achieved in all cases. The mean preoperative American Orthopaedic Foot and Ankle Society score was 37 points (range, 28-53 points) and the mean postoperative score was 88 points (range, 74-96 points), with an average improvement of 51 points. Radiographically, the mean gain in length was 13 mm (range, 10-15 mm), and the mean percentage increase was 23%. One-stage metatarsal lengthening using interposition of metatarsal homologous bone graft to correct congenital brachymetatarsia has low morbidity for the patient, limited complications, short recovery times, and restores forefoot anatomy. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  19. Tendon tissue engineering and its role on healing of the experimentally induced large tendon defect model in rabbits: a comprehensive in vivo study.

    Science.gov (United States)

    Meimandi-Parizi, Abdolhamid; Oryan, Ahmad; Moshiri, Ali

    2013-01-01

    Healing of large tendon defects is challenging. We studied the role of collagen implant with or without polydioxanone (PDS) sheath on the healing of a large Achilles tendon defect model, in rabbits. Sixty rabbits were divided into three groups. A 2 cm gap was created in the left Achilles tendon of all rabbits. In the control lesions, no implant was used. The other two groups were reconstructed by collagen and collagen-PDS implants respectively. The animals were clinically examined at weekly intervals and their lesions were observed by ultrasonography. Blood samples were obtained from the animals and were assessed for hematological analysis and determination of serum PDGF level, at 60 days post injury (DPI). The animals were then euthanized and their lesions were assessed for gross and histopathology, scanning electron microscopy, biomechanical testing, dry matter and hydroxyproline content. Another 65 pilot animals were also studied grossly and histopathologically to define the host implant interaction and graft incorporation at serial time points. The treated animals gained significantly better clinical scoring compared to the controls. Treatment with collagen and collagen-PDS implants significantly increased the biomechanical properties of the lesions compared to the control tendons at 60DPI (Ptendon. Implantation of the bioimplants had a significant role in initiating tendon healing and the implants were biocompatible, biodegradable and safe for application in tendon reconstructive surgery. The results of the present study may be valuable in clinical practice.

  20. Reconstrução do LCA com o uso dos tendões dos músculos flexores mediais do joelho e fixação femoral com o sistema de Rigidifix®: relato preliminar Anterior cruciate ligament reconstruction using double hamstrings tendon graft and the femoral fixation by Rigidifix®: preliminary Study

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Cury Faustino

    2004-12-01

    Full Text Available O autor descreve a técnica de reconstrução do LCA no tratamento das instabilidades anterior do joelho, utilizando os tendões dos músculos flexores mediais do joelho (semitendíneo e grácil, fixados no fêmur pelo sistema de Rigidfix®; e na tíbia, com parafuso de interferência absorvível, através de um estudo preliminar de 54 joelhos operados. Na avaliação final pela escala de Lysholm os pacientes evoluíram de 46 pontos no pré-operatório para 92 pontos no pós-operatório.The author describes the reconstruction technique of the anterior cruciate ligament reconstruction using the hamstrings tendon (semitendinosus and gracilis in the management of anterior instabilities of the knee joint. Rigidfix® system is used to fix the graft on the femur and an absorbable interference screw was used for tibial fixation in a preliminary study in 54 knees. The final evaluation based on Lysholm score showed an improvement from 46 (preoperative to 92 (postoperative.

  1. Bioreactor Design for Tendon/Ligament Engineering

    OpenAIRE

    Wang, Tao; Gardiner, Bruce S.; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B.; Wang, Allan; Xu, Jiake; Smith, David W.; Lloyd, David G.; Zheng, Ming H.

    2012-01-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a s...

  2. Simultaneous bilateral patellar tendon rupture.

    Science.gov (United States)

    Moura, Diogo Lino; Marques, José Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2017-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  3. Simultaneous bilateral patellar tendon rupture

    Directory of Open Access Journals (Sweden)

    Diogo Lino Moura

    Full Text Available ABSTRACT Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  4. Follow-up of volar plate interposition arthroplasty (Tupper) of the metacarpophalangeal joints in rheumatoid hands: preliminary findings

    DEFF Research Database (Denmark)

    Gøtze, J P; Jensen, Claus Hjorth

    2000-01-01

    We present the results of a three-year follow-up study of 59 interposition volar plate arthroplasties (Tupper) on metacarpophalangeal joints in 13 patients with erosive rheumatoid arthritis. The median age at the time of operation was 60 years (range 45-77). All patients reported lasting pain...

  5. Tendon overuse syndrome: imaging diagnosis

    International Nuclear Information System (INIS)

    Huber, W.; Nehrer, S.; Muellner, T.; Kainberger, F.; Ulreich, N.; Bernhard, C.; Imhof, H.

    2001-01-01

    Injuries of muscles and tendons occur commonly during various sporting activities and in most cases the athletes feel such an accident to be sudden and unavoidable. The rupture of a tendon, however, has to be considered in many cases as the final stage of a long-standing progressive degeneration of collagen fibers. This process con be described as 'tendon overuse syndrome (TOS)'. Diagnostic imaging modalities, especially sonography and MRI, are suitable to detect and analyse the different stages of this syndrome and the degree of morphological abnormalities. The first stage is painful functional derangement, followed by tendovaginitis, peritendinitis, or bursitis. The third stage is tendinosis resulting from biomechanical or ischaemic injury of tendon fibers which may eventually be followed by partial or complete rupture. Regional or individual specifications of these four stages may occur at anatomically predisposing sites, so-called critical zones, or during periods of specific proneness, the vulnerable phases. (author)

  6. Arthrography of the biceps tendon

    International Nuclear Information System (INIS)

    Ahovuo, J.; Linden, H.; Hovi, I.; Paavolainen, P.; Bjoerkenheim, J.M.

    1988-01-01

    The purpose of this study was to analyse the factors having an influence on the arthrographic imaging of the biceps tendon. The study comprised 174 patients suffering from chronic shoulder pain. They underwent conventional shoulder arthrography with sodium meglumine metrizoate or metrizamide as a contrast medium. In the patients with a full-thickness tear of the rotator cuff, the biceps tendon sheath failed to fill with contrast medium more often than in those with an intact tendinous cuff. Metrizamide filled the biceps tendon sheath more readily than sodium meglumine metrizoate in patients with a full-thickness tear of the ortator cuff. The volume of the contrast medium injected had no influence on the imaging of the biceps tendon. (orig.)

  7. Avaliação do resultado da reconstrução artroscópica do ligamento cruzado anterior do joelho com enxerto dos tendões flexores Evaluation of the results of arthroscopic ACL reconstruction with autogenous flexor tendons

    Directory of Open Access Journals (Sweden)

    Alexandre Almeida

    2010-01-01

    Full Text Available OBJETIVO: Avaliar o resultado da reconstrução do ligamento cruzado anterior (LCA com o autoenxerto dos tendões flexores da coxa. Serão analisados os dados com relação ao sexo, ao índice de massa corporal (IMC e a associação com fratura no membro inferior (MI. MÉTODOS: Foi analisado um grupo de 265 pacientes submetidos à artroscopia do joelho para fins de reconstrução do LCA com enxerto ipsilateral dos tendões flexores da coxa no período de 6 de julho de 2000 a 19 de novembro de 2007. RESULTADOS: 176 pacientes foram avaliados com média de 34,95 ± 18,8 meses (mediana 31 meses (IIQ: 20-48 meses. A avaliação mínima foi aos 12 meses e a máxima aos 87 meses. Obtivemos 138 (78,4% pacientes com resultado excelente, 22 (12,5% com resultado bom, oito (4,5% com resultado regular e oito (4,5% pacientes apresentaram resultado ruim. Não foi considerada significativa a maior incidência de bons e excelentes resultados para o sexo masculino (p = 0,128, para os pacientes com IMC OBJETIVE: To evaluate the results of single band arthroscopic anterior cruciate ligament (ACL reconstruction with flexor tendon autografts. We analyzed data about sex, body mass index (BMI and lower limb fracture associated with the initial trauma. METHODS: Two hundred and sixty-five patients who underwent arthroscopic anterior cruciate ligament (ACL reconstruction with ipsilateral thigh flexor tendon autografts from July 6, 2000, to November 19, 2007, were evaluated. RESULTS: One hundred and seventy-six patients were evaluated at an average follow up time of 34.95 ± 18.8 months (Median 31 months (IIQ: 20 - 48 months. The minimum evaluation time was 12 months and the maximum 87 months. One hundred and thirty-eight (78.4% patients had excellent results, 22 (12.5% patients good, 8 (4.5% patients fair, and 8 (4.5% poor results. No statistical significance was found for the better results for males (p = 0.128, for patients with a BMI < 25 (p = 0.848, or for patients

  8. Ulnar-sided pain due to extensor carpi ulnaris tendon subluxation: a case report

    Directory of Open Access Journals (Sweden)

    Cift Hakan

    2012-11-01

    Full Text Available Abstract Introduction We present the case of a patient with extensor carpi ulnaris tendon subluxation who was first treated for distal radioulnar joint sprain. Case presentation A 25-year-old Caucasian man was seen at our policlinic one month after he had fallen on his outstretched hand. A diagnosis of extensor carpi ulnaris subluxation was made clinically but we also had the magnetic resonance imaging scan of the patient’s wrist which displayed an increased signal on T2-weighted images consistent with inflammation around the extensor carpi ulnaris tendon. The extensor carpi ulnaris tendon was found to be dislocating during supination and relocating during pronation. The sheath was reconstructed using extensor retinaculum due to attenuation of subsheath. Conclusion There was no recurrent dislocation of the extensor carpi ulnaris tendon of the patient at his last follow up 12 months after the operation.

  9. Comparison of a novel bone-tendon allograft with a human dermis-derived patch for repair of chronic large rotator cuff tears using a canine model.

    Science.gov (United States)

    Smith, Matthew J; Cook, James L; Kuroki, Keiichi; Jayabalan, Prakash S; Cook, Cristi R; Pfeiffer, Ferris M; Waters, Nicole P

    2012-02-01

    This study tested a bone-tendon allograft versus human dermis patch for reconstructing chronic rotator cuff repair by use of a canine model. Mature research dogs (N = 15) were used. Radiopaque wire was placed in the infraspinatus tendon (IST) before its transection. Three weeks later, radiographs showed IST retraction. Each dog then underwent 1 IST treatment: debridement (D), direct repair of IST to bone with a suture bridge and human dermis patch augmentation (GJ), or bone-tendon allograft (BT) reconstruction. Outcome measures included lameness grading, radiographs, and ultrasonographic assessment. Dogs were killed 6 months after surgery and both shoulders assessed biomechanically and histologically. BT dogs were significantly (P = .01) less lame than the other groups. BT dogs had superior bone-tendon, tendon, and tendon-muscle integrity compared with D and GJ dogs. Biomechanical testing showed that the D group had significantly (P = .05) more elongation than the other groups whereas BT had stiffness and elongation characteristics that most closely matched normal controls. Radiographically, D and GJ dogs showed significantly more retraction than BT dogs (P = .003 and P = .045, respectively) Histologically, GJ dogs had lymphoplasmacytic infiltrates, tendon degeneration and hypocellularity, and poor tendon-bone integration. BT dogs showed complete incorporation of allograft bone into host bone, normal bone-tendon junctions, and well-integrated allograft tendon. The bone-tendon allograft technique re-establishes a functional IST bone-tendon-muscle unit and maintains integrity of repair in this model. Clinical trials using this bone-tendon allograft technique are warranted. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  10. Mechanical properties of human bone-tendon-bone grafts preserved by different methods and radiation sterilised

    International Nuclear Information System (INIS)

    Kaminski, A.; Gut, G.

    2008-01-01

    Full text: Patellar tendon auto and allografts are commonly used in orthopaedic surgery for reconstruction of the anterior crucial ligaments (ACL). Autografts are mainly used for primary reconstruction, while allografts are useful for revision surgery. To avoid the risk of infection diseases transmission allografts should be radiation-sterilised. As radiation-sterilisation is supposed to decrease the mechanical strength of tendon tissue, it is important to establish methods of allografts preservation and sterilisation resulting in their best quality and safety. Therefore, the purpose of the study was to compare the tensile strength of the central one third of human patellar tendon (as used for ACL reconstruction), preserved by different methods (deep fresh freezing, lyophilisation) and subsequently radiation-sterilised with doses of 0 (control), 25, 50 or 100 kGy. Bone-tendon-bone grafts were prepared from cadaveric human patella tendon with both patellar and tibial attachments. BTB grafts were preserved by deep freezing, glicerolisation or lyophilisation and radiation-sterilised with doses of 0 (control), 25, 50 or 100 kGy. To estimate mechanical properties all samples were subjected to tensile tests to failure using Instron system. Before these tests all lyophilised grafts were rehydrated. We found decrease of tensile strength of irradiated grafts compared to non-irradiated controls. Obtained results of the mechanical testing of studied grafts indicate their potential usefulness for clinical applications.(Author)

  11. Magnetic resonance imaging findings of periosteal interposition in a distal tibial Salter-Harris type I fracture with surgical correlation: A case report

    International Nuclear Information System (INIS)

    Kim, Nara; Jung, Jee Young; Kang, Ki Ser

    2013-01-01

    The complication of growth disturbance after physeal fracture of the distal tibia has been well recognized. Although irreducible fractures of the physis due to trapped soft tissue, including periosteum, are not common, it could still cause growth disturbances. Therefore, the detection of periosteal interposition with physeal injury on imaging study is important. We present a case of a 10-year-old girl with surgically confirmed periosteal interposition in the distal tibial Salter-Harris type I fracture, through magnetic resonance imaging findings.

  12. Magnetic resonance imaging findings of periosteal interposition in a distal tibial Salter-Harris type I fracture with surgical correlation: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Nara; Jung, Jee Young; Kang, Ki Ser [Chung-Ang University Hospital, Seoul (Korea, Republic of)

    2013-08-15

    The complication of growth disturbance after physeal fracture of the distal tibia has been well recognized. Although irreducible fractures of the physis due to trapped soft tissue, including periosteum, are not common, it could still cause growth disturbances. Therefore, the detection of periosteal interposition with physeal injury on imaging study is important. We present a case of a 10-year-old girl with surgically confirmed periosteal interposition in the distal tibial Salter-Harris type I fracture, through magnetic resonance imaging findings.

  13. MRI of tibialis anterior tendon rupture

    International Nuclear Information System (INIS)

    Gallo, Robert A.; DeMeo, Patrick J.; Kolman, Brett H.; Daffner, Richard H.; Sciulli, Robert L.; Roberts, Catherine C.

    2004-01-01

    Ruptures of the tibialis anterior tendon are rare. We present the clinical histories and MRI findings of three recent male patients with tibialis anterior tendon rupture aged 58-67 years, all of whom presented with pain over the dorsum of the ankle. Two of the three patients presented with complete rupture showing discontinuity of the tendon, thickening of the retracted portion of the tendon, and excess fluid in the tendon sheath. One patient demonstrated a partial tear showing an attenuated tendon with increased surrounding fluid. Although rupture of the tibialis anterior tendon is a rarely reported entity, MRI is a useful modality in the definitive detection and characterization of tibialis anterior tendon ruptures. (orig.)

  14. Repeated freeze-thaw cycles reduce the survival rate of osteocytes in bone-tendon constructs without affecting the mechanical properties of tendons.

    Science.gov (United States)

    Suto, Kaori; Urabe, Ken; Naruse, Kouji; Uchida, Kentaro; Matsuura, Terumasa; Mikuni-Takagaki, Yuko; Suto, Mitsutoshi; Nemoto, Noriko; Kamiya, Kentaro; Itoman, Moritoshi

    2012-03-01

    Frozen bone-patellar tendon bone allografts are useful in anterior cruciate ligament reconstruction as the freezing procedure kills tissue cells, thereby reducing immunogenicity of the grafts. However, a small portion of cells in human femoral heads treated by standard bone-bank freezing procedures survive, thus limiting the effectiveness of allografts. Here, we characterized the survival rates and mechanisms of cells isolated from rat bones and tendons that were subjected to freeze-thaw treatments, and evaluated the influence of these treatments on the mechanical properties of tendons. After a single freeze-thaw cycle, most cells isolated from frozen bone appeared morphologically as osteocytes and expressed both osteoblast- and osteocyte-related genes. Transmission electron microscopic observation of frozen cells using freeze-substitution revealed that a small number of osteocytes maintained large nuclei with intact double membranes, indicating that these osteocytes in bone matrix were resistant to ice crystal formation. We found that tendon cells were completely killed by a single freeze-thaw cycle, whereas bone cells exhibited a relatively high survival rate, although survival was significantly reduced after three freeze-thaw cycles. In patella tendons, the ultimate stress, Young's modulus, and strain at failure showed no significant differences between untreated tendons and those subjected to five freeze-thaw cycles. In conclusion, we identified that cells surviving after freeze-thaw treatment of rat bones were predominantly osteocytes. We propose that repeated freeze-thaw cycles could be applied for processing bone-tendon constructs prior to grafting as the treatment did not affect the mechanical property of tendons and drastically reduced surviving osteocytes, thereby potentially decreasing allograft immunogenecity.

  15. Achilles Tendon's Tear

    OpenAIRE

    F. Shahandeh

    2008-01-01

    Introduction: The achilles and plantaris tendons to-gether makeup the posterior grouptendons of ankle. Their seldom confusion in interpreting MR images of the achilles tendon. The achilles tendon should ap-pear informally straight and black on sagital T1 weighted images and on fluid sensitive images."nCase Presentation: After a heavy sport, a 55 year-old woman cannot walk with right foot."nDiscussion: The classic achilles tendon rupture occurs with forced dorsiflexion of planted foo...

  16. Pathophysiology of overuse tendon injury

    International Nuclear Information System (INIS)

    Kannus, P.; Paavola, M.; Paakkala, T.; Parkkari, J.; Jaervinen, T.; Jaervinen, M.

    2002-01-01

    Overuse tendon injury is one of the most common injuries in sports.The etiology as well as the pathophysilogical mechanisms leading to tendinopathy are of crucial medical importance.At the moment intrinsic and extrinsic factors are assumed as mechanisms of overuse tendon injury. Except for the acute, extrinsic trauma, the chronic overuse tendon injury is a multifactorial process. There are many other factors, such as local hypoxia, less of nutrition, impaired metabolism and local inflammatory that may also contribute to the development of tissue damage.The exact interaction of these factors cannot be explained entirely at the moment.Further studies will be necessary in order to get more information. (orig.) [de

  17. Osteocalcin expressing cells from tendon sheaths in mice contribute to tendon repair by activating Hedgehog signaling

    OpenAIRE

    Wang, Yi; Zhang, Xu; Huang, Huihui; Xia, Yin; Yao, YiFei; Mak, Arthur Fuk-Tat; Yung, Patrick Shu-Hang; Chan, Kai-Ming; Wang, Li; Zhang, Chenglin; Huang, Yu; Mak, Kingston King-Lun

    2017-01-01

    Both extrinsic and intrinsic tissues contribute to tendon repair, but the origin and molecular functions of extrinsic tissues in tendon repair are not fully understood. Here we show that tendon sheath cells harbor stem/progenitor cell properties and contribute to tendon repair by activating Hedgehog signaling. We found that Osteocalcin (Bglap) can be used as an adult tendon-sheath-specific marker in mice. Lineage tracing experiments show that Bglap-expressing cells in adult sheath tissues pos...

  18. Spontaneous Achilles tendon rupture in alkaptonuria | Mohammed ...

    African Journals Online (AJOL)

    Spontaneous Achilles tendon ruptures are uncommon. We present a 46-year-old man with spontaneous Achilles tendon rupture due to ochronosis. To our knowledge, this has not been previously reported in Sudan literature. The tendon of the reported patient healed well after debridement and primary repairs.

  19. Two-stage reconstruction with the modified Paneva-Holevich technique.

    LENUS (Irish Health Repository)

    O'Shea, Kieran

    2013-05-01

    Flexor tendon reconstruction poses both a technical challenge to the hand surgeon and a rehabilitative challenge to the patient and therapist. The modified Paneva-Holevich technique, using a pedicled intra-synovial graft, is a safe and reliable means of staged flexor tendon reconstruction, offering a number of theoretical advantages over classic free-tendon grafting techniques. Clinical outcomes are at the least comparable, if not superior, to those achieved following free-tendon techniques with most authors reporting a low requirement for third stage tenolysis.

  20. Orthotopic Transplantation of Achilles Tendon Allograft in Rats

    Science.gov (United States)

    Aynardi, Michael; Zahoor, Talal; Mitchell, Reed; Loube, Jeffrey; Feltham, Tyler; Manandhar, Lumanti; Paudel, Sharada; Schon, Lew; Zhang, Zijun

    2018-01-01

    The biology and function of orthotopic transplantation of Achilles tendon allograft are unknown. Particularly, the revitalization of Achilles allograft is a clinical concern. Achilles allografts were harvested from donor rats and stored at −80 °C. Subcutaneous adipose tissue was harvested from the would-be allograft recipient rats for isolation of mesenchymal stem cells (MSCs). MSCs were cultured with growth differentiation factor-5 (GDF-5) and applied onto Achilles allografts on the day of transplantation. After the native Achilles tendon was resected from the left hind limb of the rats, Achilles allograft, with or without autologous MSCs, was implanted and sutured with calf muscles proximally and calcaneus distally. Animal gait was recorded presurgery and postsurgery weekly. The animals were sacrificed at week 4, and the transplanted Achilles allografts were collected for biomechanical testing and histology. The operated limbs had altered gait. By week 4, the paw print intensity, stance time, and duty cycle (percentage of the stance phase in a step cycle) of the reconstructed limbs were mostly recovered to the baselines recorded before surgery. Maximum load of failure was not different between Achilles allografts, with or without MSCs, and the native tendons. The Achilles allograft supplemented with MSCs had higher cellularity than the Achilles allograft without MSCs. Deposition of fine collagen (type III) fibers was active in Achilles allograft, with or without MSCs, but it was more evenly distributed in the allografts that were incubated with MSCs. In conclusion, orthotopically transplanted Achilles allograft healed with host tissues, regained strength, and largely restored Achilles function in 4 wk in rats. It is therefore a viable option for the reconstruction of a large Achilles tendon defect. Supplementation of MSCs improved repopulation of Achilles allograft, but large animal models, with long-term follow up and cell tracking, may be required to fully

  1. Experience with 32 Pelvic Fracture Urethral Defects Associated with Urethrorectal Fistulas: Transperineal Urethroplasty with Gracilis Muscle Interposition.

    Science.gov (United States)

    Guo, Hailin; Sa, Yinglong; Fu, Qiang; Jin, Chongrui; Wang, Lin

    2017-07-01

    Pelvic fracture urethral defects associated with urethrorectal fistulas are rare and difficult to repair. The aim of this study was to evaluate the efficacy of transperineal urethroplasty with gracilis muscle interposition for the repair of pelvic fracture urethral defects associated with urethrorectal fistulas. We identified 32 patients who underwent transperineal urethroplasty with gracilis muscle interposition to repair pelvic fracture urethral defects associated with urethrorectal fistulas. Patient demographics as well as preoperative, operative and postoperative data were obtained. Mean followup was 33 months (range 6 to 64). The overall success rate was 91% (29 of 32 cases). One-stage repair was successful in 17 of 18 patients (94%) using perineal anastomosis with separation of the corporeal body and in 12 of 14 (86%) using perineal anastomosis with inferior pubectomy and separation of the corporeal body. All 22 patients (100%) without a previous history of repair were successfully treated. However, only 7 of 10 patients (70%) with a previous history of failed urethroplasty and urethrorectal fistula repair were cured. Recurrent urethral strictures developed in 2 cases. One patient was treated successfully with optical internal urethrotomy and the other was treated successfully with tubed perineoscrotal flap urethroplasty. Recurrent urethrorectal fistulas associated with urethral strictures developed in an additional patient. Transperineal urethroplasty with gracilis muscle interposition is a safe and effective surgical procedure for most pelvic fracture urethral defects associated with urethrorectal fistulas. Several other factors may affect its postoperative efficiency. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. The role of three-dimensional pure bovine gelatin scaffolds in tendon healing, modeling, and remodeling: an in vivo investigation with potential clinical value.

    Science.gov (United States)

    Oryan, Ahmad; Sharifi, Pardis; Moshiri, Ali; Silver, Ian A

    2017-09-01

    Large tendon defects involving extensive tissue loss present complex clinical problems. Surgical reconstruction of such injuries is normally performed by transplanting autogenous and allogenous soft tissues that are expected to remodel to mimic a normal tendon. However, the use of grafts has always been associated with significant limitations. Tissue engineering employing artificial scaffolds may provide acceptable alternatives. Gelatin is a hydrolyzed form of collagen that is bioactive, biodegradable, and biocompatible. The present study has investigated the suitability of gelatin scaffold for promoting healing of a large tendon-defect model in rabbits. An experimental model of a large tendon defect was produced by partial excision of the Achilles tendon of the left hind leg in adult rabbits. To standardize and stabilize the length of the tendon defect a modified Kessler core suture was anchored in the sectioned tendon ends. The defects were either left untreated or filled with three-dimensional gelatin scaffold. Before euthanasia 60 days after injury, the progress of healing was evaluated clinically. Samples of healing tendon were harvested at autopsy and evaluated by gross, histopathologic, scanning, and transmission electron microscopy, and by biomechanical testing. The treated animals showed superior weight-bearing and physical activity compared with those untreated, while frequency of peritendinous adhesions around the healing site was reduced. The gelatin scaffold itself was totally degraded and replaced by neo-tendon that morphologically had significantly greater numbers, diameters, density, and maturation of collagen fibrils, fibers, and fiber bundles than untreated tendon scar tissue. It also had mechanically higher ultimate load, yield load, stiffness, maximum stress and elastic modulus, when compared to the untreated tendons. Gelatin scaffold may be a valuable option in surgical reconstruction of large tendon defects.

  3. Can PRP effectively treat injured tendons?

    Science.gov (United States)

    Wang, James H-C

    2014-01-01

    PRP is widely used to treat tendon and other tissue injuries in orthopaedics and sports medicine; however, the efficacy of PRP treatment on injured tendons is highly controversial. In this commentary, I reason that there are many PRP- and patient-related factors that influence the outcomes of PRP treatment on injured tendons. Therefore, more basic science studies are needed to understand the mechanism of PRP on injured tendons. Finally, I suggest that better understanding of the PRP action mechanism will lead to better use of PRP for the effective treatment of tendon injuries in clinics.

  4. Bioreactor design for tendon/ligament engineering.

    Science.gov (United States)

    Wang, Tao; Gardiner, Bruce S; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B; Wang, Allan; Xu, Jiake; Smith, David W; Lloyd, David G; Zheng, Ming H

    2013-04-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a suitable culture environment, which mimics the dynamics of the in vivo environment for tendon/ligament maturation. For clinical settings, bioreactors also have the advantages of less-contamination risk, high reproducibility of cell propagation by minimizing manual operation, and a consistent end product. In this review, we identify the key components, design preferences, and criteria that are required for the development of an ideal bioreactor for engineering tendons and ligaments.

  5. Tendoscopy of the peroneal tendons

    NARCIS (Netherlands)

    van Dijk, C. N.; Kort, N.

    1998-01-01

    An anatomic cadaver study was performed. Subsequently, in a prospective study, diagnostic and therapeutic tendoscopy (tendon sheath endoscopy) was performed in nine consecutive patients with a history of persistent posterolateral ankle pain for at least 6 months. All patients had pain on palpation

  6. Smart Tendon Actuated Flexible Actuator

    Directory of Open Access Journals (Sweden)

    Md. Masum Billah

    2015-01-01

    Full Text Available We investigate the kinematic feasibility of a tendon-based flexible parallel platform actuator. Much of the research on tendon-driven Stewart platforms is devoted either to the completely restrained positioning mechanism (CRPM or to one particular type of the incompletely restrained positioning mechanism (IRPM where the external force is provided by the gravitational pull on the platform such as in cable-suspended Stewart platforms. An IRPM-based platform is proposed which uses the external force provided by a compliant member. The compliant central column allows the configuration to achieve n DOFs with n tendons. In particular, this investigation focuses on the angular deflection of the upper platform with respect to the lower platform. The application here is aimed at developing a linkable module that can be connected to one another so as to form a “snake robot” of sorts. Since locomotion takes precedence over positioning in this application, a 3-DOF Stewart platform is adopted. For an arbitrary angular displace of the end-effector, the corresponding length of each tendon can be determined through inverse kinematics. Mathematical singularities are investigated using the traditional analytical method of defining the Jacobian.

  7. Treatment of postparotidectomy Frey syndrome with the interposition of temporalis fascia and sternocleidomastoid flaps.

    Science.gov (United States)

    Dai, Xiao-Ming; Liu, Hua; He, Jia; Tu, Min-Song; Yu, Li-Fu; Liu, Liu

    2015-05-01

    This study was performed to evaluate the effectiveness of overlapping the temporalis fascia flaps (TFFs) and the sternocleidomastoid muscle flaps (SCMFs) as physical barriers to treat established Frey syndrome and concavity after parotidectomy. We retrospectively reviewed 17 patients who underwent corrective procedures with simultaneous TFF and SCMF interposition for the treatment of Frey syndrome. The affected areas of the cheek skin were identified with starch-iodine tests. The facial contours of the patients were classified as bilaterally symmetric (BS), with a slightly shallow (SS) contour on the surgical side, or with a conspicuously shallow (CS) contour on the surgical side. The sample was followed up for a mean of 22 months. The average area of gustatory-sweating positive skin was reduced from 12.80 to 1.32 square centimeters postoperatively. The facial asymmetry secondary to parotidectomy was greatly improved. The authors concluded that this technique was efficacious in ameliorating Frey syndrome and facial concavity secondary to parotidectomy. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Outcome of different facial nerve reconstruction techniques.

    Science.gov (United States)

    Mohamed, Aboshanif; Omi, Eigo; Honda, Kohei; Suzuki, Shinsuke; Ishikawa, Kazuo

    There is no technique of facial nerve reconstruction that guarantees facial function recovery up to grade III. To evaluate the efficacy and safety of different facial nerve reconstruction techniques. Facial nerve reconstruction was performed in 22 patients (facial nerve interpositional graft in 11 patients and hypoglossal-facial nerve transfer in another 11 patients). All patients had facial function House-Brackmann (HB) grade VI, either caused by trauma or after resection of a tumor. All patients were submitted to a primary nerve reconstruction except 7 patients, where late reconstruction was performed two weeks to four months after the initial surgery. The follow-up period was at least two years. For facial nerve interpositional graft technique, we achieved facial function HB grade III in eight patients and grade IV in three patients. Synkinesis was found in eight patients, and facial contracture with synkinesis was found in two patients. In regards to hypoglossal-facial nerve transfer using different modifications, we achieved facial function HB grade III in nine patients and grade IV in two patients. Facial contracture, synkinesis and tongue atrophy were found in three patients, and synkinesis was found in five patients. However, those who had primary direct facial-hypoglossal end-to-side anastomosis showed the best result without any neurological deficit. Among various reanimation techniques, when indicated, direct end-to-side facial-hypoglossal anastomosis through epineural suturing is the most effective technique with excellent outcomes for facial reanimation and preservation of tongue movement, particularly when performed as a primary technique. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  9. Outcome of different facial nerve reconstruction techniques

    Directory of Open Access Journals (Sweden)

    Aboshanif Mohamed

    Full Text Available Abstract Introduction: There is no technique of facial nerve reconstruction that guarantees facial function recovery up to grade III. Objective: To evaluate the efficacy and safety of different facial nerve reconstruction techniques. Methods: Facial nerve reconstruction was performed in 22 patients (facial nerve interpositional graft in 11 patients and hypoglossal-facial nerve transfer in another 11 patients. All patients had facial function House-Brackmann (HB grade VI, either caused by trauma or after resection of a tumor. All patients were submitted to a primary nerve reconstruction except 7 patients, where late reconstruction was performed two weeks to four months after the initial surgery. The follow-up period was at least two years. Results: For facial nerve interpositional graft technique, we achieved facial function HB grade III in eight patients and grade IV in three patients. Synkinesis was found in eight patients, and facial contracture with synkinesis was found in two patients. In regards to hypoglossal-facial nerve transfer using different modifications, we achieved facial function HB grade III in nine patients and grade IV in two patients. Facial contracture, synkinesis and tongue atrophy were found in three patients, and synkinesis was found in five patients. However, those who had primary direct facial-hypoglossal end-to-side anastomosis showed the best result without any neurological deficit. Conclusion: Among various reanimation techniques, when indicated, direct end-to-side facial-hypoglossal anastomosis through epineural suturing is the most effective technique with excellent outcomes for facial reanimation and preservation of tongue movement, particularly when performed as a primary technique.

  10. Hyperuricemic PRP in Tendon Cells

    Directory of Open Access Journals (Sweden)

    I. Andia

    2014-01-01

    Full Text Available Platelet-rich plasma (PRP is injected within tendons to stimulate healing. Metabolic alterations such as the metabolic syndrome, diabetes, or hyperuricemia could hinder the therapeutic effect of PRP. We hypothesise that tendon cells sense high levels of uric acid and this could modify their response to PRP. Tendon cells were treated with allogeneic PRPs for 96 hours. Hyperuricemic PRP did not hinder the proliferative actions of PRP. The gene expression pattern of inflammatory molecules in response to PRP showed absence of IL-1b and COX1 and modest expression of IL6, IL8, COX2, and TGF-b1. IL8 and IL6 proteins were secreted by tendon cells treated with PRP. The synthesis of IL6 and IL8 proteins induced by PRP is decreased significantly in the presence of hyperuricemia (P = 0.017 and P = 0.012, resp.. Concerning extracellular matrix, PRP-treated tendon cells displayed high type-1 collagen, moderate type-3 collagen, decorin, and hyaluronan synthase-2 expression and modest expression of scleraxis. Hyperuricemia modified the expression pattern of extracellular matrix proteins, upregulating COL1 (P = 0.036 and COMP (P = 0.012 and downregulating HAS2 (P = 0.012. Positive correlations between TGF-b1 and type-1 collagen (R = 0.905, P = 0.002 and aggrecan (R = 0.833, P = 0.010 and negative correlations between TGF-b1 and IL6 synthesis (R = −0.857, P = 0.007 and COX2 (R = −0.810, P = 0.015 were found.

  11. Magnetotherapy: The quest for tendon regeneration.

    Science.gov (United States)

    Pesqueira, Tamagno; Costa-Almeida, Raquel; Gomes, Manuela E

    2018-05-09

    Tendons are mechanosensitive tissues that connect and transmit the forces generated by muscles to bones by allowing the conversion of mechanical input into biochemical signals. These physical forces perform the fundamental work of preserving tendon homeostasis assuring body movements. However, overloading causes tissue injuries, which leads us to the field of tendon regeneration. Recently published reviews have broadly shown the use of biomaterials and different strategies to attain tendon regeneration. In this review, our focus is the use of magnetic fields as an alternative therapy, which has demonstrated clinical relevance in tendon medicine because of their ability to modulate cell fate. Yet the underlying cellular and molecular mechanisms still need to be elucidated. While providing a brief outlook about specific signalling pathways and intracellular messengers as framework in play by tendon cells, application of magnetic fields as a subcategory of physical forces is explored, opening up a compelling avenue to enhance tendon regeneration. We outline here useful insights on the effects of magnetic fields both at in vitro and in vivo levels, particularly on the expression of tendon genes and inflammatory cytokines, ultimately involved in tendon regeneration. Subsequently, the potential of using magnetically responsive biomaterials in tendon tissue engineering is highlighted and future directions in magnetotherapy are discussed. © 2018 Wiley Periodicals, Inc.

  12. High-resolution study of the 3D collagen fibrillary matrix of Achilles tendons without tissue labelling and dehydrating.

    Science.gov (United States)

    Wu, Jian-Ping; Swift, Benjamin John; Becker, Thomas; Squelch, Andrew; Wang, Allan; Zheng, Yong-Chang; Zhao, Xuelin; Xu, Jiake; Xue, Wei; Zheng, Minghao; Lloyd, David; Kirk, Thomas Brett

    2017-06-01

    Knowledge of the collagen structure of an Achilles tendon is critical to comprehend the physiology, biomechanics, homeostasis and remodelling of the tissue. Despite intensive studies, there are still uncertainties regarding the microstructure. The majority of studies have examined the longitudinally arranged collagen fibrils as they are primarily attributed to the principal tensile strength of the tendon. Few studies have considered the structural integrity of the entire three-dimensional (3D) collagen meshwork, and how the longitudinal collagen fibrils are integrated as a strong unit in a 3D domain to provide the tendons with the essential tensile properties. Using second harmonic generation imaging, a 3D imaging technique was developed and used to study the 3D collagen matrix in the midportion of Achilles tendons without tissue labelling and dehydration. Therefore, the 3D collagen structure is presented in a condition closely representative of the in vivo status. Atomic force microscopy studies have confirmed that second harmonic generation reveals the internal collagen matrix of tendons in 3D at a fibril level. Achilles tendons primarily contain longitudinal collagen fibrils that braid spatially into a dense rope-like collagen meshwork and are encapsulated or wound tightly by the oblique collagen fibrils emanating from the epitenon region. The arrangement of the collagen fibrils provides the longitudinal fibrils with essential structural integrity and endows the tendon with the unique mechanical function for withstanding tensile stresses. A novel 3D microscopic method has been developed to examine the 3D collagen microstructure of tendons without tissue dehydrating and labelling. The study also provides new knowledge about the collagen microstructure in an Achilles tendon, which enables understanding of the function of the tissue. The knowledge may be important for applying surgical and tissue engineering techniques to tendon reconstruction. © 2017 The Authors

  13. Phrenic nerve reconstruction in complete video-assisted thoracic surgery.

    Science.gov (United States)

    Kawashima, Shun; Kohno, Tadasu; Fujimori, Sakashi; Yokomakura, Naoya; Ikeda, Takeshi; Harano, Takashi; Suzuki, Souichiro; Iida, Takahiro; Sakai, Emi

    2015-01-01

    Primary or metastatic lung cancer or mediastinal tumours may at times involve the phrenic nerve and pericardium. To remove the pathology en bloc, the phrenic nerve must be resected. This results in phrenic nerve paralysis, which in turn reduces pulmonary function and quality of life. As a curative measure of this paralysis and thus a preventive measure against decreased pulmonary function and quality of life, we have performed immediate phrenic nerve reconstruction under complete video-assisted thoracic surgery, and with minimal additional stress to the patient. This study sought to ascertain the utility of this procedure from an evaluation of the cases experienced to date. We performed 6 cases of complete video-assisted thoracic surgery phrenic nerve reconstruction from October 2009 to December 2013 in patients who had undergone phrenic nerve resection or separation to remove tumours en bloc. In all cases, it was difficult to separate the phrenic nerve from the tumour. Reconstruction involved direct anastomosis in 3 cases and intercostal nerve interposition anastomosis in the remaining 3 cases. In the 6 patients (3 men, 3 women; mean age 50.8 years), we performed two right-sided and four left-sided procedures. The mean anastomosis time was 5.3 min for direct anastomosis and 35.3 min for intercostal nerve interposition anastomosis. Postoperative phrenic nerve function was measured on chest X-ray during inspiration and expiration. Direct anastomosis was effective in 2 of the 3 patients, and intercostal nerve interposition anastomosis was effective in all 3 patients. Diaphragm function was confirmed on X-ray to be improved in these 5 patients. Complete video-assisted thoracic surgery phrenic nerve reconstruction was effective for direct anastomosis as well as for intercostal nerve interposition anastomosis in a small sample of selected patients. The procedure shows promise for phrenic nerve reconstruction and further data should be accumulated over time. © The

  14. Functional reconstruction of ischemic contracture in the

    Directory of Open Access Journals (Sweden)

    TANG Hao

    2011-04-01

    Full Text Available 【Abstract】Objective: To discuss the method of functional reconstruction of ischemic contracture in the lower limb and propose a classification protocol for ischemic contracture in the lower limb based on its severity and prognosis. Methods: A total of 42 patients with ischemic contracture in the lower limb were included in this study. According to different types of disturbance and degrees of severity, surgical reconstructions consisting of nerve decompression, tendon lengthening or transfer, intrinsic foot muscle release and sural-tibial nerve anastomosis were performed in every patient. Results: Postoperatively, all patients were able to walk on flat ground. Drop foot was corrected in 10 patients, and 5 patients still felt some difficulty during stair activity. Split Achilles tendon transfer to flexor hallucis longus tendon was performed in 12 patients, and their walking stability was improved. Seven patients accepted ipsilateral suraltibial nerve anastomosis, and sensitivity recovery reached to S2 in 2 patients and S3 in 5 patients. Conclusions: Ischemic contracture in the lower limb is a devastating complication after lower limb trauma. The prevention of contracture is much more important than the treatment of an established contracture. Split Achilles tendon transfer to flexor hallucis longus tendon and sural-tibial nerve anastomosis, which was initially implemented by us, could improve the functional recovery of ischemic contracture in lower limbs, and thus provides a new alternative for functional reconstruction of ischemic contracture in the lower limb. Key words: Ischemic contracture; Classification; Recovery of function

  15. Implantation of a novel biologic and hybridized tissue engineered bioimplant in large tendon defect: an in vivo investigation.

    Science.gov (United States)

    Oryan, Ahmad; Moshiri, Ali; Parizi, Abdolhamid Meimandi; Maffulli, Nicola

    2014-02-01

    Surgical reconstruction of large Achilles tendon defects is technically demanding. There is no standard method, and tissue engineering may be a valuable option. We investigated the effects of 3D collagen and collagen-polydioxanone sheath (PDS) implants on a large tendon defect model in rabbits. Ninety rabbits were divided into three groups: control, collagen, and collagen-PDS. In all groups, 2 cm of the left Achilles tendon were excised and discarded. A modified Kessler suture was applied to all injured tendons to retain the gap length. The control group received no graft, the treated groups were repaired using the collagen only or the collagen-PDS prostheses. The bioelectrical characteristics of the injured areas were measured at weekly intervals. The animals were euthanized at 60 days after the procedure. Gross, histopathological and ultrastructural morphology and biophysical characteristics of the injured and intact tendons were investigated. Another 90 pilot animals were also used to investigate the inflammatory response and mechanism of graft incorporation during tendon healing. The control tendons showed severe hyperemia and peritendinous adhesion, and the gastrocnemius muscle of the control animals showed severe atrophy and fibrosis, with a loose areolar connective tissue filling the injured area. The tendons receiving either collagen or collagen-PDS implants showed lower amounts of peritendinous adhesion, hyperemia and muscle atrophy, and a dense tendon filled the defect area. Compared to the control tendons, application of collagen and collagen-PDS implants significantly improved water uptake, water delivery, direct transitional electrical current and tissue resistance to direct transitional electrical current. Compared to the control tendons, both prostheses showed significantly increased diameter, density and alignment of the collagen fibrils and maturity of the tenoblasts at ultrastructure level. Both prostheses influenced favorably tendon healing

  16. Active Achilles tendon kinesitherapy accelerates Achilles tendon repair by promoting neurite regeneration.

    Science.gov (United States)

    Jielile, Jiasharete; Aibai, Minawa; Sabirhazi, Gulnur; Shawutali, Nuerai; Tangkejie, Wulanbai; Badelhan, Aynaz; Nuerduola, Yeermike; Satewalede, Turde; Buranbai, Darehan; Hunapia, Beicen; Jialihasi, Ayidaer; Bai, Jingping; Kizaibek, Murat

    2012-12-15

    Active Achilles tendon kinesitherapy facilitates the functional recovery of a ruptured Achilles tendon. However, protein expression during the healing process remains a controversial issue. New Zealand rabbits, aged 14 weeks, underwent tenotomy followed immediately by Achilles tendon microsurgery to repair the Achilles tendon rupture. The tendon was then immobilized or subjected to postoperative early motion treatment (kinesitherapy). Mass spectrography results showed that after 14 days of motion treatment, 18 protein spots were differentially expressed, among which, 12 were up-regulated, consisting of gelsolin isoform b and neurite growth-related protein collapsing response mediator protein 2. Western blot analysis showed that gelsolin isoform b was up-regulated at days 7-21 of motion treatment. These findings suggest that active Achilles tendon kinesitherapy promotes the neurite regeneration of a ruptured Achilles tendon and gelsolin isoform b can be used as a biomarker for Achilles tendon healing after kinesitherapy.

  17. Active Achilles tendon kinesitherapy accelerates Achilles tendon repair by promoting neurite regeneration☆

    Science.gov (United States)

    Jielile, Jiasharete; Aibai, Minawa; Sabirhazi, Gulnur; Shawutali, Nuerai; Tangkejie, Wulanbai; Badelhan, Aynaz; Nuerduola, Yeermike; Satewalede, Turde; Buranbai, Darehan; Hunapia, Beicen; Jialihasi, Ayidaer; Bai, Jingping; Kizaibek, Murat

    2012-01-01

    Active Achilles tendon kinesitherapy facilitates the functional recovery of a ruptured Achilles tendon. However, protein expression during the healing process remains a controversial issue. New Zealand rabbits, aged 14 weeks, underwent tenotomy followed immediately by Achilles tendon microsurgery to repair the Achilles tendon rupture. The tendon was then immobilized or subjected to postoperative early motion treatment (kinesitherapy). Mass spectrography results showed that after 14 days of motion treatment, 18 protein spots were differentially expressed, among which, 12 were up-regulated, consisting of gelsolin isoform b and neurite growth-related protein collapsing response mediator protein 2. Western blot analysis showed that gelsolin isoform b was up-regulated at days 7–21 of motion treatment. These findings suggest that active Achilles tendon kinesitherapy promotes the neurite regeneration of a ruptured Achilles tendon and gelsolin isoform b can be used as a biomarker for Achilles tendon healing after kinesitherapy. PMID:25317130

  18. Effect of estrogen on tendon collagen synthesis, tendon structural characteristics, and biomechanical properties in postmenopausal women

    DEFF Research Database (Denmark)

    Hansen, Mette; Kongsgaard, Mads; Holm, Lars

    2009-01-01

    and fibril characteristics were determined by MRI and transmission electron microscopy, whereas tendon biomechanical properties were measured during isometric maximal voluntary contraction by ultrasound recording. Tendon FSR was markedly higher in ERT-users (P

  19. Tendon Force Transmission at the Nanoscale

    DEFF Research Database (Denmark)

    Svensson, René

    2013-01-01

    of connective tissue function that are poorly understood. One such aspect is the microscopic mechanisms of force transmission through tendons over macroscopic distances. Force transmission is at the heart of tendon function, but the large range of scales in the hierarchical structure of tendons has made...... it difficult to tackle. The tendon hierarchy ranges from molecules (2 nm) over fibrils (200 nm), fibers (2 μm) and fascicles (200 μm) to tendons (10 mm), and to derive the mechanisms of force transmission it is necessary to know the mechanical behavior at each hierarchical level. The aim of the present work...... was to elucidate the mechanisms of force transmission in tendons primarily by investigating the mechanical behavior at the hierarchical level of collagen fibrils. To do so we have developed an atomic force microscopy (AFM) method for tensile testing of native collagen fibrils. The thesis contains five papers...

  20. Do cells contribute to tendon and ligament biomechanics?

    Directory of Open Access Journals (Sweden)

    Niels Hammer

    Full Text Available Acellular scaffolds are increasingly used for the surgical repair of tendon injury and ligament tears. Despite this increased use, very little data exist directly comparing acellular scaffolds and their native counterparts. Such a comparison would help establish the effectiveness of the acellularization procedure of human tissues. Furthermore, such a comparison would help estimate the influence of cells in ligament and tendon stability and give insight into the effects of acellularization on collagen.Eighteen human iliotibial tract samples were obtained from nine body donors. Nine samples were acellularized with sodium dodecyl sulphate (SDS, while nine counterparts from the same donors remained in the native condition. The ends of all samples were plastinated to minimize material slippage. Their water content was adjusted to 69%, using the osmotic stress technique to exclude water content-related alterations of the mechanical properties. Uniaxial tensile testing was performed to obtain the elastic modulus, ultimate stress and maximum strain. The effectiveness of the acellularization procedure was histologically verified by means of a DNA assay.The histology samples showed a complete removal of the cells, an extensive, yet incomplete removal of the DNA content and alterations to the extracellular collagen. Tensile properties of the tract samples such as elastic modulus and ultimate stress were unaffected by acellularization with the exception of maximum strain.The data indicate that cells influence the mechanical properties of ligaments and tendons in vitro to a negligible extent. Moreover, acellularization with SDS alters material properties to a minor extent, indicating that this method provides a biomechanical match in ligament and tendon reconstruction. However, the given protocol insufficiently removes DNA. This may increase the potential for transplant rejection when acellular tract scaffolds are used in soft tissue repair. Further research

  1. Achilles tendon rupture in badminton.

    Science.gov (United States)

    Kaalund, S; Lass, P; Høgsaa, B; Nøhr, M

    1989-01-01

    The typical badminton player with an Achilles tendon rupture is 36 years old and, despite limbering up, is injured at the rear line in a sudden forward movement. He resumes work within three months and has a slight lack of dorsiflexion in the ankle as the main complication. Most patients resume badminton within one year, but some finish their sports career, mainly due to fear of a new injury. The investigation discusses predisposing factors and prophylactic measures. PMID:2605439

  2. Ropivacaine alters the mechanical properties of hamstring tendons: In vitro controlled mechanical testing of tendons from living donors.

    Science.gov (United States)

    Ollivier, M; Sbihi, J; Sbihi, A; Pithioux, M; Parratte, S; Argenson, J-N

    2017-11-01

    Intraarticular or periarticular injection of ropivacaine (RI) is an element of current knee surgery practices. The goal of this study was to determine the effects of RI on the mechanical properties of hamstring tendons. We hypothesized that RI would have a detrimental effect on the mechanical properties of periarticular soft tissues METHODS: A tensile test to failure was performed on 120 hamstring tendon segments harvested during ACL reconstruction surgery in 120 patients. Two sets of tensile tests were done. The first evaluated the effect of RI itself on the mechanical properties of tendons: 30 samples were soaked for 1hour in a 2% RI solution and compared to 30 samples soaked in a saline solution (control group). The second evaluated the effect of RI concentration on the mechanical properties of hamstring tendons: 30 samples were soaked for 1hour in a 2% RI solution and 30 samples were soaked in a 7.5% RI solution. In the first test, 29 samples from each group were analyzed as two samples (one in each group) failed at the grip interface. The specimens exposed to 2% RI had lower ultimate tensile strength (Δ=4.4MPa, P=0.001), strain energy (Δ=13MPa, P=0.001) and Young's modulus (Δ=1.6MPa, P=0.02) than the specimens in the control group. There was no significant difference in the strain at failure between groups (Δ=5%, P=0.3). In the second test, one specimen from the 7.5% RI group failed during the preloading and was excluded. There was no significant difference in terms of the load at failure and ultimate tensile stress (Δ=0.45MPa, P=0.6) and strain energy (Δ=0.49MPa, P=0.49) between the two groups. There were significant differences in terms of elongation at failure (Δ=28%, P=0.0003) and Young's modulus (Δ=2.6MPa, P=0.005), with the specimens exposed to 7.5% RI undergoing greater deformation and having a lower Young's modulus. While local RI injections are widely performed in clinical practice, the results of this in vitro study point to short

  3. The roentgenographic findings of achilles tendon rupture

    Energy Technology Data Exchange (ETDEWEB)

    Seouk, Kang Hyo; Keun, Rho Yong [Shilla General Hospital, Seoul (Korea, Republic of)

    1999-03-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture.

  4. The roentgenographic findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Seouk, Kang Hyo; Keun, Rho Yong

    1999-01-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture

  5. Tendon sheath fibroma in the thigh.

    Science.gov (United States)

    Moretti, Vincent M; Ashana, Adedayo O; de la Cruz, Michael; Lackman, Richard D

    2012-04-01

    Tendon sheath fibromas are rare, benign soft tissue tumors that are predominantly found in the fingers, hands, and wrists of young adult men. This article describes a tendon sheath fibroma that developed in the thigh of a 70-year-old man, the only known tendon sheath fibroma to form in this location. Similar to tendon sheath fibromas that develop elsewhere, our patient's lesion presented as a painless, slow-growing soft tissue nodule. Physical examination revealed a firm, nontender mass with no other associated signs or symptoms. Although the imaging appearance of tendon sheath fibromas varies, our patient's lesion appeared dark on T1- and bright on T2-weighted magnetic resonance imaging. It was well marginated and enhanced with contrast.Histologically, tendon sheath fibromas are composed of dense fibrocollagenous stromas with scattered spindle-shaped fibroblasts and narrow slit-like vascular spaces. Most tendon sheath fibromas can be successfully removed by marginal excision, although 24% of lesions recur. No lesions have metastasized. Our patient's tendon sheath fibroma was removed by marginal excision, and the patient remained disease free 35 months postoperatively. Despite its rarity, tendon sheath fibroma should be included in the differential diagnosis of a thigh mass on physical examination or imaging, especially if it is painless, nontender, benign appearing, and present in men. Copyright 2012, SLACK Incorporated.

  6. Condition Assessment of PC Tendon Duct Filling by Elastic Wave Velocity Mapping

    Directory of Open Access Journals (Sweden)

    Kit Fook Liu

    2014-01-01

    Full Text Available Imaging techniques are high in demand for modern nondestructive evaluation of large-scale concrete structures. The travel-time tomography (TTT technique, which is based on the principle of mapping the change of propagation velocity of transient elastic waves in a measured object, has found increasing application for assessing in situ concrete structures. The primary aim of this technique is to detect defects that exist in a structure. The TTT technique can offer an effective means for assessing tendon duct filling of prestressed concrete (PC elements. This study is aimed at clarifying some of the issues pertaining to the reliability of the technique for this purpose, such as sensor arrangement, model, meshing, type of tendon sheath, thickness of sheath, and material type as well as the scale of inhomogeneity. The work involved 2D simulations of wave motions, signal processing to extract travel time of waves, and tomography reconstruction computation for velocity mapping of defect in tendon duct.

  7. MRI findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Zhang Xuezhe

    2009-01-01

    Objective: To evaluate the MRI findings of achilles tendon rupture. Methods: The MRI data of 7 patients with achilles tendon rupture were retrospectively analysed. All 7 patients were male with the age ranging from 34 to 71 years. Routine MR scanning was performed in axial and sagittal planes, including T 1 WI, T 2 WI and a fat suppression MRI (SPIR). Results: Among 7 patients, complete achilles tendon rupture was seen in 6 cases, partial achilles tendon rupture 1 case. The site of tendon disruption were 2.6-11.0 cm( mean 5.4 cm) proximal to the insertion in the calcaneus. The MRI findings of a partial or complete rupture of the achilles tendon included enlarged and thickened achilles tendon (7 cases), wavy lax achilles tendon (2 cases), discontinuity of some or all of its fibers and intratendinous regions of increased signal intensity (7 cases). In the cases of complete tendon rupture, the size of the tendinous gap varied from 3.0-8.0 mm, which was filled with blood and appeared as edema of increase signal intensity on T 2 WI and SPIR. In all 7 patients, MR scanning showed medium signal intensity (7 cases) on T 1 WI, or medium signal intensity (1 cases), medium-high signal intensity (3 cases ), high signal intensity (3 cases) on T 2 WI, and medium-high signal intensity (2 cases), high signal intensity (5 cases) on fat suppression MRI. The preachilles fat pad showed obscure in 6 cases of complete achilles tendon rupture. Conclusion: MRI is an excellent method for revealing achilles tendon rupture and confirming the diagnosis. (authors)

  8. A Pilot Study of Common Bile Duct Reconstruction with CorMatrix Extracellular Matrix in Swine (Sus scrofa)

    Science.gov (United States)

    2015-02-06

    additional pages if necessary.) PROTOCOL#: FDG20140008A DATE: 6 February 2015 PROTOCOL TITLE: A Pilot Study of Common Bile Duct Reconstruction with...obstruction or bile peritonitis. This was reported to the IACUC chair. 9. REDUCTION, REFINEMENT, OR REPLACEMENT OF ANIMAL USE; REPLACEMENT...benefit the DoD/USAF? We developed a porcine model of common bile duct injury and interposition grafting, gained experience managing these patients

  9. Kartogenin with PRP promotes the formation of fibrocartilage zone in the tendon-bone interface.

    Science.gov (United States)

    Zhou, Yiqin; Zhang, Jianying; Yang, Jinsong; Narava, Manoj; Zhao, Guangyi; Yuan, Ting; Wu, Haishan; Zheng, Nigel; Hogan, MaCalus V; Wang, James H-C

    2017-12-01

    Treatment of tendon-bone junction injuries is a challenge because tendon-bone interface often heals poorly and the fibrocartilage zone, which reduces stress concentration, at the interface is not formed. In this study, we used a compound called kartogenin (KGN) with platelet-rich plasma (PRP) to induce the formation of fibrocartilage zone in a rat tendon graft-bone tunnel model. The experimental rats received KGN-PRP or PRP injections in the tendon graft-bone tunnel interface. The control group received saline. After 4, 8 and 12 weeks, Safranin O staining of the tendon graft-bone tunnels revealed abundant proteoglycans in the KGN-PRP group indicating the formation of cartilage-like transition zone. Immunohistochemical and immuno-fluorescence staining revealed collagen types I (Col-I) and II (Col-II) in the newly formed fibrocartilage zone. Both fibrocartilage zone formation and maturation were healing time dependent. In contrast, the PRP and saline control groups had no cartilage-like tissues and minimal Col-I and Col-II staining. Some gaps were also present in the saline control group. Finally, pull-out strength in the KGN-PRP-treated group at 8 weeks was 1.4-fold higher than the PRP-treated group and 1.6-fold higher than the saline control group. These findings indicate that KGN, with PRP as a carrier, promotes the formation of fibrocartilage zone between the tendon graft and bone interface. Thus, KGN-PRP may be used as a convenient cell-free therapy in clinics to promote fibrocartilage zone formation in rotator calf repair and anterior cruciate ligament reconstruction, thereby enhancing the mechanical strength of the tendon-bone interface and hence the clinical outcome of these procedures. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Mechanical Properties of Human Patellar Tendon at the Hierarchical levels of Tendon and Fibril

    DEFF Research Database (Denmark)

    Svensson, Rene Brüggebusch; Hansen, Philip; Hassenkam, Tue

    2012-01-01

    Tendons are strong hierarchical structures, but how tensile forces are transmitted between different levels remains incompletely understood. Collagen fibrils are thought to be primary determinants of whole tendon properties, and therefore we hypothesized that the whole human patellar tendon and its...... distinct collagen fibrils would display similar mechanical properties. Human patellar tendons (n=5) were mechanically tested in vivo by ultrasonography. Biopsies were obtained from each tendon and individual collagen fibrils were dissected and tested mechanically by atomic force microscopy. The Young...... that of tendon supports that fibrillar rather than interfibrillar properties govern sub-failure tendon response, making the fibrillar level a meaningful target of intervention. The lower modulus found in vitro suggests a possible adverse effect of removing the tissue from its natural environment. In addition...

  11. Tissue engineering approaches to develop decellularized tendon matrices functionalized with progenitor cells cultured under undifferentiated and tenogenic conditions

    Directory of Open Access Journals (Sweden)

    Daniele D’Arrigo

    2017-11-01

    Full Text Available Tendon ruptures and retractions with an extensive tissue loss represent a major clinical problem and a great challenge in surgical reconstruction. Traditional approaches consist in autologous or allogeneic grafts, which still have some drawbacks. Hence, tissue engineering strategies aimed at developing functionalized tendon grafts. In this context, the use of xenogeneic tissues represents a promising perspective to obtain decellularized tendon grafts. This study is focused on the identification of suitable culture conditions for the generation of reseeded and functional decellularized constructs to be used as tendon grafts. Equine superficial digital flexor tendons were decellularized, reseeded with mesenchymal stem cells (MSCs from bone marrow and statically cultured in two different culture media to maintain undifferentiated cells (U-MSCs or to induce a terminal tenogenic differentiation (T-MSCs for 24 hours, 7 and 14 days. Cell viability, proliferation, morphology as well as matrix deposition and type I and III collagen production were assessed by means of histological, immunohistochemical and semi-quantitative analyses. Results showed that cell viability was not affected by any culture conditions and active proliferation was maintained 14 days after reseeding. However, seeded MSCs were not able to penetrate within the dense matrix of the decellularized tendons. Nevertheless, U-MSCs synthesized a greater amount of extracellular matrix rich in type I collagen compared to T-MSCs. In spite of the inability to deeply colonize the decellularized matrix in vitro, reseeding tendon matrices with U-MSCs could represent a suitable method for the functionalization of biological constructs, considering also any potential chemoattractant capability of the newly deposed extracellular matrix to recruit resident cells. This bioengineering approach can be exploited to produce functionalized tendon constructs for the substitution of large tendon defects.

  12. Simulation of tendon energy storage in pedaling

    DEFF Research Database (Denmark)

    Rasmussen, John; Damsgaard, Michael; Christensen, Søren Tørholm

    2001-01-01

    The role of elastic energy stored in tendons during pedaling is investigated by means of numerical simulation using the AnyBody body modeling system. The loss of metabolic energy due to tendon elasticity is computed and compared to the mechanical work involved in the process. The AnyBody simulati...

  13. Rupture of Achilles Tendon : Usefulness of Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Nam Hyeon; Ki, Won Woo; Yoon, Kwon Ha; Kim, Song Mun; Shin, Myeong Jin; Kwon, Soon Tae

    1996-01-01

    To differentiate a complete rupture of Achilles tendon from an incomplete one which is important because its treatment is quite different. And it is necessary to know the exact site of the rupture preoperatively. Fifteen cases of fourteen patients which were diagnosed as Achilles tendon rupture by ultrasonography and surgery were reviewed. We compared sonographic rupture site with surgical findings. Ultrasonographic criteria for differentiation of complete and incomplete rupture was defined as follows : the discreteness, which means the proximal intervening hypoechogenicity to the interface echogenicity of distal margin of ruptured tendon : the slant sign, which represents the interface of ruptured distal margin which was seen over the 3/4 of the thickness of the tendon without intervening low echogeneicity : the invagination sign, which means the echogenic invagination from Kager triangle into posterior aspect of Achilles tendon over the half thickness of the tendon. The sites of complete tendon rupture were exactly corresponded to surgical finding in four cases of ten complete ruptures. And the discrepancy between sonographic and surgical findings in the site of complete rupture was 1.2 ± 0.4 cm in six cases. Three of ten complete ruptures showed the discreteness sign, all of ten showed the slant sign and two of ten showed the invagination sign. It is helpful to differentiate a complete from incomplete rupture of the Achilles tendon and to localize the site of the complete rupture with the ultrasonographic evaluation

  14. Measuring Regional Changes in Damaged Tendon

    Science.gov (United States)

    Frisch, Catherine Kayt Vincent

    Mechanical properties of tendon predict tendon health and function, but measuring these properties in vivo is difficult. An ultrasound-based (US) analysis technique called acoustoelastography (AE) uses load-dependent changes in the reflected US signal to estimate tissue stiffness non-invasively. This thesis explores whether AE can provide information about stiffness alteration resulting from tendon tears both ex vivo and in vivo. An ex vivo ovine infraspinatus tendon model suggests that the relative load transmitted by the different tendon layers transmit different fractions of the load and that ultrasound echo intensity change during cyclic loading decreases, becoming less consistent once the tendon is torn. An in vivo human tibialis anterior tendon model using electrically stimulated twitch contractions investigated the feasibility of measuring the effect in vivo. Four of the five subjects showed the expected change and that the muscle contraction times calculated using the average grayscale echo intensity change compared favorably with the times calculated based on the force data. Finally an AE pilot study with patients who had rotator cuff tendon tears found that controlling the applied load and the US view of the system will be crucial to a successful in vivo study.

  15. Bilateral synchronous rupture of the quadriceps tendon.

    LENUS (Irish Health Repository)

    Ellanti, P

    2012-09-01

    Bilateral simultaneous rupture of the quadriceps tendon is a rare entity. They are often associated with degenerative changes of the tendons and predisposing conditions such as diabetes or excessive steroid use. They most commonly tend to occur in patients of 40 years of age or older.

  16. Thompson Test in Achilles Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Spencer Albertson

    2016-07-01

    Full Text Available HPI: A 26-year old male presented to the emergency department after experiencing the acute onset of left ankle pain while playing basketball. Upon jumping, he felt a “pop” in his left posterior ankle, followed by pain and difficulty ambulating. His exam was notable for a defect at the left Achilles tendon on palpation. The practitioner performed a Thompson test, which was positive (abnormal on the left. Significant Findings: The left Achilles tendon had a defect on palpation, while the right Achilles tendon was intact. When squeezing the right (unaffected calf, the ankle spontaneously plantar flexed, indicating a negative (normal Thompson test. Upon squeeze of the left (affected calf, the ankle did not plantar flex, signifying a positive (abnormal Thompson test. The diagnosis of left Achilles tendon rupture was confirmed intraoperatively one week later. Discussion: The Achilles tendon (also: calcaneal tendon or heel cord is derived from the medial and lateral heads of the gastrocnemius muscle, as well as the soleus muscle. Rupture of the Achilles tendon most commonly occurs in the distal tendon, approximately 2-6 cm from its attachment to the calcaneal tuberosity, in an area of hypovascularity known as the “watershed” or “critical” zone.1-3 The Thompson test (also: Simmonds-Thompson test, described by Simmonds in 1957 and Thompson in 1962, is done while the patient is in the prone position, with feet hanging over the end of a table/gurney, or with the patient kneeling on a stool or chair.4-5 Squeezing the calf of an unaffected limb will cause the ankle to plantar flex, but squeezing the calf of a limb with an Achilles tendon rupture will cause no motion. The sensitivity of the Thompson’s test for the diagnosis of a complete Achilles tendon rupture is 96-100% and the specificity is 93-100%, but data is limited.6-8

  17. THE ROLE OF DETRAINING IN TENDON MECHANOBIOLOGY

    Directory of Open Access Journals (Sweden)

    Antonio eFrizziero

    2016-02-01

    Full Text Available Introduction: Several conditions such as training, aging, estrogen deficiency and drugs could affect the biological and anatomo-physiological characteristics of the tendon. Additionally, recent preclinical and clinical studies examined the effect of detraining on tendon, showing alterations in its structure and morphology and in tenocyte mechanobiology. However, there is a paucity of data examining the impact that cessation of training may have on tendon. In practice, we do not fully understand how tendons respond to a period of training followed by sudden detraining. Therefore, within this review, we summarize the studies where tendon detraining was examined.Materials and methods: A descriptive systematic literature review was conducted by searching three databases (PubMed, Scopus and Web of Knowledge on tendon detraining. Original articles in English from 2000 to 2015 were included. In addition, the search was extended to the reference lists of the selected articles. A public reference manager (www.mendeley.com was used to delete duplicate articles.Results: An initial literature search yielded 134 references (www.pubmed.org: 53; www.scopus.com: 11; www.webofknowledge.com: 70. 15 publications were extracted based on the title for further analysis by two independent reviewers. Abstracts and whole articles were then reviewed to detect if they met inclusion criteria.Conclusions: The revised literature comprised 4 clinical studies and an in vitro and three in vivo reports. Overall, the results showed that tendon structure and properties after detraining are compromised, with an alteration in the tissue structural organization and mechanical properties. Clinical studies usually showed a lesser extent of tendon alterations, probably because preclinical studies permit an in-depth evaluation of tendon modifications, which is hard to perform in human subjects. In conclusion, after a period of sudden detraining (e.g. after an injury, physical activity

  18. Epidural fat interposition between dura mater and spinous process: a new sign for the diagnosis of spondylolysis on MR imaging of the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Sherif, Hanan; Mahfouz, Ahmed-Emad [Department of Radiology, Hamad Medical Corporation, P.O. Box 3050, Doha (Qatar)

    2004-06-01

    The purpose of this study was to assess the diagnostic value of epidural fat interposition between the dura mater and spinous process of L5 as an indirect sign of spondylolysis on mid-sagittal MR imaging of the lumbar spine. Mid-sagittal T1-weighted MR images of the lumbar spine of 85 patients with spondylolysis and 93 patients without pars interarticularis fractures were randomized and evaluated by a masked reader. After a training sample of five cases, the reader was asked to note the presence or absence of epidural fat interposition between the dura mater and spinous process of L5 on the randomized images. The epidural fat interposition between the dura mater and spinous process of L5 was noted in 67 out of the 85 patients with spondylolysis (78.8%) and three of the patients without pars interarticularis fracture (3.2%). The difference was statistically significant (P<0.01). This sign has a specificity of 96.7%, sensitivity of 78.8%, positive predictive value of 95.7%, negative predictive value of 83.3% and accuracy of 88.2% for diagnosis of spondylolysis. Epidural fat interposition between the dura mater and spinous process may be a helpful sign for the diagnosis of spondylolysis on mid-sagittal MR imaging of the lumbar spine. (orig.)

  19. Epidural fat interposition between dura mater and spinous process: a new sign for the diagnosis of spondylolysis on MR imaging of the lumbar spine

    International Nuclear Information System (INIS)

    Sherif, Hanan; Mahfouz, Ahmed-Emad

    2004-01-01

    The purpose of this study was to assess the diagnostic value of epidural fat interposition between the dura mater and spinous process of L5 as an indirect sign of spondylolysis on mid-sagittal MR imaging of the lumbar spine. Mid-sagittal T1-weighted MR images of the lumbar spine of 85 patients with spondylolysis and 93 patients without pars interarticularis fractures were randomized and evaluated by a masked reader. After a training sample of five cases, the reader was asked to note the presence or absence of epidural fat interposition between the dura mater and spinous process of L5 on the randomized images. The epidural fat interposition between the dura mater and spinous process of L5 was noted in 67 out of the 85 patients with spondylolysis (78.8%) and three of the patients without pars interarticularis fracture (3.2%). The difference was statistically significant (P<0.01). This sign has a specificity of 96.7%, sensitivity of 78.8%, positive predictive value of 95.7%, negative predictive value of 83.3% and accuracy of 88.2% for diagnosis of spondylolysis. Epidural fat interposition between the dura mater and spinous process may be a helpful sign for the diagnosis of spondylolysis on mid-sagittal MR imaging of the lumbar spine. (orig.)

  20. Serial superficial digital flexor tendon biopsies for diagnosing and monitoring collagenase-induced tendonitis in horses

    Directory of Open Access Journals (Sweden)

    José C. de Lacerda Neto

    2013-06-01

    Full Text Available The purpose of this investigation was to demonstrate the feasibility of a biopsy technique by performing serial evaluations of tissue samples of the forelimb superficial digital flexor tendon (SDFT in healthy horses and in horses subjected to superficial digital flexor tendonitis induction. Eight adult horses were evaluated in two different phases (P, control (P1 and tendonitis-induced (P2. At P1, the horses were subjected to five SDFT biopsies of the left forelimb, with 24 hours (h of interval. Clinical and ultrasonographic (US examinations were performed immediately before the tendonitis induction, 24 and 48 h after the procedure. The biopsied tendon tissues were analyzed through histology. P2 evaluations were carried out three months later, when the same horses were subjected to tendonitis induction by injection of bacterial collagenase into the right forelimb SDFT. P2 clinical and US evaluations, and SDFT biopsies were performed before, and after injury induction at the following time intervals: after 24, 48, 72 and 96 h, and after 15, 30, 60, 90, 120 and 150 days. The biopsy technique has proven to be easy and quick to perform and yielded good tendon samples for histological evaluation. At P1 the horses did not show signs of localised inflammation, pain or lameness, neither SDFT US alterations after biopsies, showing that the biopsy procedure per se did not risk tendon integrity. Therefore, this procedure is feasible for routine tendon histological evaluations. The P2 findings demonstrate a relation between the US and histology evaluations concerning induced tendonitis evolution. However, the clinical signs of tendonitis poorly reflected the microscopic tissue condition, indicating that clinical presentation is not a reliable parameter for monitoring injury development. The presented method of biopsying SDFT tissue in horses enables the serial collection of material for histological analysis causing no clinical signs and tendon damage seen

  1. Achilles tendon: US diagnosis of pathologic conditions. Work in progress

    International Nuclear Information System (INIS)

    Blei, C.L.; Nirschl, R.P.; Grant, E.G.

    1986-01-01

    Twenty-three patients were prospectively examined with ultra-sound (US) for acute or recurrent Achilles tendon symptoms. Three types of pathologic conditions of the Achilles tendon were found: tendinitis/tenosynovitis, acute tendon trauma, and postoperative changes. US appears to enable differentiation of these conditions and to contribute to the diagnosis of a broad range of Achilles tendon disorders

  2. Achilles tendon: US diagnosis of pathologic conditions. Work in progress

    Energy Technology Data Exchange (ETDEWEB)

    Blei, C.L.; Nirschl, R.P.; Grant, E.G.

    1986-06-01

    Twenty-three patients were prospectively examined with ultra-sound (US) for acute or recurrent Achilles tendon symptoms. Three types of pathologic conditions of the Achilles tendon were found: tendinitis/tenosynovitis, acute tendon trauma, and postoperative changes. US appears to enable differentiation of these conditions and to contribute to the diagnosis of a broad range of Achilles tendon disorders.

  3. Micromechanical properties and collagen composition of ruptured human achilles tendon

    DEFF Research Database (Denmark)

    Hansen, Philip; Kovanen, Vuokko; Hölmich, Per

    2013-01-01

    The Achilles tendon is one of the strongest tendons in the human body, and yet it frequently ruptures, which is a substantial clinical problem. However, the cause of ruptures remains elusive.......The Achilles tendon is one of the strongest tendons in the human body, and yet it frequently ruptures, which is a substantial clinical problem. However, the cause of ruptures remains elusive....

  4. Region-specific mechanical properties of the human patella tendon

    DEFF Research Database (Denmark)

    Haraldsson, B T; Aagaard, P; Krogsgaard, M

    2004-01-01

    The present study investigated the mechanical properties of tendon fascicles from the anterior and posterior human patellar tendon. Collagen fascicles from the anterior and posterior human patellar tendon in healthy young men (mean +/- SD, 29.0 +/- 4.6 yr, n = 6) were tested in a mechanical rig...... portion of the tendon, indicating region-specific material properties....

  5. High-field MR imaging of the tendons

    International Nuclear Information System (INIS)

    Beltran, J.; Burk, J.M.; Herman, L.J.; Mosure, J.C.

    1987-01-01

    MR imaging was used to investigate normal anatomy and pathologic conditions of the tendons. Tendons of experimental animals, cadaver joints, normal volunteers, and patients with suspected tendon pathology were studied. Tendon anatomy is easily identified because of the hypointensity of the tendons contrasting with the hyperintendensity of the surrounding fat. Pathologic conditions including posttraumatic and postsurgical tendon rupture, peritendinous scarring, tendinitis, and tenosynovitis are well seen with MR imaging. A detailed study of normal and abnormal tendon anatomy of the finger, wrist, shoulder, knee, and ankle is displayed, including MR images, gross specimens, and line drawings

  6. Shortened stapedius tendon: a rare cause of conductive hearing loss.

    Science.gov (United States)

    Zawawi, F; Varshney, R; Schloss, M D

    2014-01-01

    Anomalies of the stapedius tendon have been reported to cause conductive hearing loss; in theory, such anomalies limit the movement of the stapes. To demonstrate a rare cause of conductive hearing loss resulting from anomaly of the stapedius tendon and to compare the clinical findings of this patient to other stapedius tendon anomalies reported in the literature. Case report of a single case of shortened stapedius tendon and a review of the English literature on stapedius tendon anomalies. This is a case report of a 15-year-old boy with shortened stapedius tendon causing unilateral hearing loss, accompanied by a review of the literature. Contrary to other reported cases, this patient did not have an ossified tendon, but rather an extremely short tendon. The boy regained normal hearing following excision of the stapedius tendon. A shortened stapedius tendon is a very rare diagnosis, yet it should be considered as a possible cause of conductive hearing loss.

  7. Fibroma of the tendon sheath of the long head of the biceps tendon

    International Nuclear Information System (INIS)

    Maeseneer, Michel de; Shahabpour, Maryam; Isacker, Tom van; Lenchik, Leon; Caillie, Marie-Astrid van

    2014-01-01

    Fibroma of the tendon sheath is a benign tumor that is less common than giant cell tumor of the tendon sheath. Both tumors may present as a painless, slowly enlarging mass. Radiological findings may be similar for both tumors. Histologically, fibroma of the tendon sheath lacks the hemosiderin-laden macrophages that are typical for giant cell tumor of the tendon sheath. We report on a 49-year-old woman with fibroma of the tendon sheath of the long head of the biceps tendon. In our case, on MR images, we observed band-like hypointense areas centrally in the tumor, mild patchy contrast enhancement, and most importantly, no decrease of signal intensity on gradient echo images. These characteristics reflected histological findings. (orig.)

  8. Congenital cheek teratoma with temporo-mandibular joint ankylosis managed with ultra-thin silicone sheet interpositional arthroplasty.

    Science.gov (United States)

    Bhatnagar, Ankur; Verma, Vinay Kumar; Purohit, Vishal

    2013-01-01

    Primary cheek teratomas are rare with joint ankylosis (TMJA). The fundamental aim in the treatment of TMJA is the successful surgical resection of ankylotic bone, prevention of recurrence, and aesthetic improvement by ensuring functional occlusion. Early treatment is necessary to promote proper growth and function of mandible and to facilitate the positive psychological development of child. Inter-positional arthroplasty with ultra-thin silicone sheet was performed. Advantages include short operative time, less foreign material in the joint space leading to negligible foreign body reactions and least chances of implant extrusion. Instead of excising a large bony segment, a thin silicone sheet was interposed and then sutured ensuring preservation of mandibular height. Aggressive post-operative physiotherapy with custom made dynamic jaw exerciser was used to prevent recurrence.

  9. Heterotopic ossification of the elbow after closed reduction and retrograde intramedullary nailing for radial neck fracture treated by anconeus interposition.

    Science.gov (United States)

    Sreenivas, T; Menon, Jagdish; Nataraj, A R

    2013-12-01

    Heterotopic ossification around the elbow can lead to considerable functional disability. We describe a case of a 42-year-old man who developed heterotopic ossification of his elbow after closed reduction of the elbow dislocation and radial neck fracture and retrograde intramedullary nailing for radial neck fracture. During the follow-up after initial surgery, movements of the elbow were gradually deteriorated and diagnosed as heterotopic ossification of the elbow. Implant removal, radial head excision along with heterotopic mass, and also interposition of the anconeus muscle resulted in improvement of his elbow mobility. At 18 months of follow-up, patient had elbow flexion arc of 15°-110°, 70° of supination, and 50° of pronation without recurrence of heterotopic ossification. The uniqueness of this case lies in the treatment of heterotopic ossification of the elbow to prevent its recurrence, which was developed after retrograde intramedullary nailing for radial neck fracture following closed reduction.

  10. Arthroscopic-Assisted Triangular Fibrocartilage Complex Reconstruction.

    Science.gov (United States)

    Chu-Kay Mak, Michael; Ho, Pak-Cheong

    2017-11-01

    Injury of the triangular fibrocartilage complex (TFCC) is a common cause of ulnar-sided wrist pain. Volar and dorsal radioulnar ligaments and their foveal insertion are the most important stabilizing components of the TFCC. In irreparable tears, anatomic reconstruction of the TFCC aims to restore normal biomechanics and stability of the distal radioulnar joint. We proposed a novel arthroscopic-assisted technique using a palmaris longus tendon graft. Arthroscopic-assisted TFCC reconstruction is a safe and effective approach with outcomes comparable to conventional open reconstruction and may result in a better range of motion from minimizing soft tissue dissection and subsequent scarring. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. [Flexor tendon repair: a short story].

    Science.gov (United States)

    Moutet, F; Corcella, D; Forli, A; Mesquida, V

    2014-12-01

    This short story of flexor tendon repair aims to illustrate hesitations and wanderings of this surgery. Obviously tendon repair was very early considered, but it developed and diffused rather lately. It became a routine practice only in 20th century. This was due on the one hand, in Occident, to the Galen's dogmatic interdiction, on the other hand, to the repair difficulties of this paradoxical structure. Actually tendon is made of fibroblasts and collagen (sticky substances), and then its only goal is to move. According to this necessity, whatever the used techniques are, gliding is the final purpose. Technical evolutions are illustrated by historical contributions to flexor tendon surgery of several "giants" of hand surgery. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  12. Terminology for Achilles tendon related disorders

    NARCIS (Netherlands)

    van Dijk, C. N.; van Sterkenburg, M. N.; Wiegerinck, J. I.; Karlsson, J.; Maffulli, N.

    2011-01-01

    The terminology of Achilles tendon pathology has become inconsistent and confusing throughout the years. For proper research, assessment and treatment, a uniform and clear terminology is necessary. A new terminology is proposed; the definitions hereof encompass the anatomic location, symptoms,

  13. Endoscopic Treatment of Intrasheath Peroneal Tendon Subluxation

    Directory of Open Access Journals (Sweden)

    Frederick Michels

    2013-01-01

    Full Text Available Intrasheath subluxation of the peroneal tendons within the peroneal groove is an uncommon problem. Open exploration combined with a peroneal groove-deepening procedure and retinacular reefing is the recommended treatment. This extensive lateral approach needs incision of the intact superior peroneal retinaculum and repair afterwards. We treated three patients with a painful intrasheath subluxation using an endoscopic approach. During this tendoscopy both tendons were inspected. The distal muscle fibers of the peroneus brevis tendon were resected in two patients. A partial tear was debrided in the third patient. All patients had a good result. No wound-healing problems or other complications occurred. Early return to work and sports was possible. An endoscopic approach was successful in treatment of an intrasheath subluxation of the peroneal tendons.

  14. Jumper's Knee (Patellar Tendonitis) (For Parents)

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Jumper's Knee (Patellar Tendonitis) KidsHealth / For Parents / Jumper's Knee (Patellar ... prevent continued damage to the knee. How the Knee Works To understand how jumper's knee happens, it ...

  15. Experimental tests of pretensioned high strength tendons

    International Nuclear Information System (INIS)

    Hajutin, J.G.; Kriczewskij, A.Z.

    1977-01-01

    The tests carried out to estimate the losses of the prestressing force and the real bearing capacity of the parallel wire tendons and seven-wire strands are described. The practical experiences in tenden anchoring etc. are also received. (author)

  16. Investigations related to failure of prestressing tendons

    International Nuclear Information System (INIS)

    Boyadjiev, Z.

    1995-01-01

    Kozloduy NPP units 5 and 6 containment cladding shells are prestressed by the use of tendons 450 φ 5, made of high strength wires, class B-II. The prestressing force for each tendon is 10000 kN and the calculated breakdown force - 14000 kN. There are 96 tendons in the cylindrical part of the shell and 36 ones located in the containment dome. They are located in channel forming tubes of inner diameter of 200 mm, made of dense polyethylene. In order to assure biaxial prestressed condition, the prestressing tendons are located on screw shaped lines, both left and right, with declination to the horizon 35 degrees and 15 minutes. Each prestressing tendon initially forms a knee and following the bending at elevation + 10.80 m forms the other knee, in such a way, that its two ends are anchored in one and the same area-in a common or adjacent upper anchor boxes. The prestressing tendons in the containment dome are located in two perpendicular rows. Both ends of each tendon are anchored in a common fixing, the tendon being bent to the opposite side of the dome. During construction and operation of units 5 and 6, it was found, that the design prestressing force of 10000 kN can not be reached with some tendons, due to separate wires ruptures or due to the anchoring screw spent thread. The 1992 preliminary wires tests on a failed tendon found out deformation properties, different from the systematically obtained ones for the initial steel. Taking into consideration this fact, together with the IAEA regional project, concerning WWER-1000 seismic safety and items 4 and 6 of Kozloduy NPP Technical Council decisions of 10 June 1993, brought to delegation to the Research Construction Institute the performance of the technical analysis of the applied system for shell prestressing of containments of of units 5 and 6. The analysis comprises physical-mechanical and rheological properties of the high strength wires, used for containment shell prestressing and the over all technological

  17. Synovial Mesenchymal Stem Cells Promote Meniscus Regeneration Augmented by an Autologous Achilles Tendon Graft in a Rat Partial Meniscus Defect Model

    Science.gov (United States)

    Ozeki, Nobutake; Muneta, Takeshi; Matsuta, Seiya; Koga, Hideyuki; Nakagawa, Yusuke; Mizuno, Mitsuru; Tsuji, Kunikazu; Mabuchi, Yo; Akazawa, Chihiro; Kobayashi, Eiji; Saito, Tomoyuki; Sekiya, Ichiro

    2015-01-01

    Although meniscus defects and degeneration are strongly correlated with the later development of osteoarthritis, the promise of regenerative medicine strategies is to prevent and/or delay the disease's progression. Meniscal reconstruction has been shown in animal models with tendon grafting and transplantation of mesenchymal stem cells (MSCs); however, these procedures have not shown the same efficacy in clinical studies. Here, our aim was to investigate the ability of tendon grafts pretreated with exogenous synovial-derived MSCs to prevent cartilage degeneration in a rat partial meniscus defect model. We removed the anterior half of the medial meniscus and grafted autologous Achilles tendons with or without a 10-minute pretreatment of the tendon with synovial MSCs. The meniscus and surrounding cartilage were evaluated at 2, 4, and 8 weeks (n = 5). Tendon grafts increased meniscus size irrespective of synovial MSCs. Histological scores for regenerated menisci were better in the tendon + MSC group than in the other two groups at 4 and 8 weeks. Both macroscopic and histological scores for articular cartilage were significantly better in the tendon + MSC group at 8 weeks. Implanted synovial MSCs survived around the grafted tendon and native meniscus integration site by cell tracking assays with luciferase+, LacZ+, DiI+, and/or GFP+ synovial MSCs and/or GFP+ tendons. Flow cytometric analysis showed that transplanted synovial MSCs retained their MSC properties at 7 days and host synovial tissue also contained cells with MSC characteristics. Synovial MSCs promoted meniscus regeneration augmented by autologous Achilles tendon grafts and prevented cartilage degeneration in rats. Stem Cells 2015;33:1927–1938 PMID:25993981

  18. Dynamic ultrasound of peroneal tendon instability.

    Science.gov (United States)

    Pesquer, Lionel; Guillo, Stéphane; Poussange, Nicolas; Pele, Eric; Meyer, Philippe; Dallaudière, Benjamin

    2016-07-01

    Ankle snapping may be caused by peroneal tendon instability. Anterior instability occurs after traumatic superior peroneal retinaculum injury, whereas peroneal tendon intrasheath subluxation is atraumatic. Whereas subluxation is mainly dynamic, ultrasound allows for the diagnosis and classification of peroneal instability because it allows for real-time exploration. The purpose of this review is to describe the anatomic and physiologic bases for peroneal instability and to heighten the role of dynamic ultrasound in the diagnosis of snapping.

  19. Microsurgical reconstruction of extensive oncological scalp defects

    Directory of Open Access Journals (Sweden)

    Ole eGoertz

    2015-09-01

    Full Text Available While most small to medium defects of the scalp can be covered by local flaps, large defects or complicating factors like a history of radiotherapy often require a microsurgical reconstruction.Several factors need to be considered in such procedures. A sufficient preoperative planning is based on adequate imaging of the malignancy and a multi-disciplinary concept. Several flaps are available for such reconstructions, of which the latissimus dorsi and anterior lateral thigh flaps are the most commonly used ones.In very large defects, combined flaps such as a parascapular / latissimus dorsi flaps can be highly useful or necessary. The most commonly used recipient vessels for microsurgical scalp reconstructions are the superficial temporal vessels, but various other feasible choices exist. If the concomitant veins are not sufficient, the jugular veins represent a safe backup alternative but require a vessel interposition or long pedicle. Postoperative care and patient positioning can be difficult in these patients but can be facilitated by various devices. Overall, microsurgical reconstruction of large scalp defects is a feasible undertaking if the mentioned key factors are taken into account.

  20. Optimization of human tendon tissue engineering: peracetic acid oxidation for enhanced reseeding of acellularized intrasynovial tendon.

    Science.gov (United States)

    Woon, Colin Y L; Pridgen, Brian C; Kraus, Armin; Bari, Sina; Pham, Hung; Chang, James

    2011-03-01

    Tissue engineering of human flexor tendons combines tendon scaffolds with recipient cells to create complete cell-tendon constructs. Allogenic acellularized human flexor tendon has been shown to be a useful natural scaffold. However, there is difficulty repopulating acellularized tendon with recipient cells, as cell penetration is restricted by a tightly woven tendon matrix. The authors evaluated peracetic acid treatment in optimizing intratendinous cell penetration. Cadaveric human flexor tendons were harvested, acellularized, and divided into experimental groups. These groups were treated with peracetic acid in varying concentrations (2%, 5%, and 10%) and for varying time periods (4 and 20 hours) to determine the optimal treatment protocol. Experimental tendons were analyzed for differences in tendon microarchitecture. Additional specimens were reseeded by incubation in a fibroblast cell suspension at 1 × 10(6) cells/ml. This group was then analyzed for reseeding efficacy. A final group underwent biomechanical studies for strength. The optimal treatment protocol comprising peracetic acid at 5% concentration for 4 hours produced increased scaffold porosity, improving cell penetration and migration. Treated scaffolds did not show reduced collagen or glycosaminoglycan content compared with controls (p = 0.37 and p = 0.65, respectively). Treated scaffolds were cytotoxic to neither attached cells nor the surrounding cell suspension. Treated scaffolds also did not show inferior ultimate tensile stress or elastic modulus compared with controls (p = 0.26 and p = 0.28, respectively). Peracetic acid treatment of acellularized tendon scaffolds increases matrix porosity, leading to greater reseeding. It may prove to be an important step in tissue engineering of human flexor tendon using natural scaffolds.

  1. Grasp Assist Device with Shared Tendon Actuator Assembly

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Bergelin, Bryan J. (Inventor); Bridgwater, Lyndon (Inventor)

    2015-01-01

    A grasp assist device includes a glove with first and second tendon-driven fingers, a tendon, and a sleeve with a shared tendon actuator assembly. Tendon ends are connected to the respective first and second fingers. The actuator assembly includes a drive assembly having a drive axis and a tendon hook. The tendon hook, which defines an arcuate surface slot, is linearly translatable along the drive axis via the drive assembly, e.g., a servo motor thereof. The flexible tendon is routed through the surface slot such that the surface slot divides the flexible tendon into two portions each terminating in a respective one of the first and second ends. The drive assembly may include a ball screw and nut. An end cap of the actuator assembly may define two channels through which the respective tendon portions pass. The servo motor may be positioned off-axis with respect to the drive axis.

  2. Liquifying PLDLLA Anchor Fixation in Achilles Reconstruction for Insertional Tendinopathy.

    Science.gov (United States)

    Boden, Stephanie A; Boden, Allison L; Mignemi, Danielle; Bariteau, Jason T

    2018-04-01

    Insertional Achilles tendinopathy (IAT) is a frequent cause of posterior heel pain and is often associated with Haglund's deformity. Surgical correction for refractory cases of IAT has been well studied; however, the method of tendon fixation to bone in these procedures remains controversial, and to date, no standard technique has been identified for tendon fixation in these surgeries. Often, after Haglund's resection, there is large exposed cancellous surface for Achilles reattachment, which may require unique fixation to optimize outcomes. Previous studies have consistently demonstrated improved patient outcomes after Achilles tendon reconstruction with early rehabilitation with protected weight bearing, evidencing the need for a strong and stable anchoring of the Achilles tendon that allows early weight bearing without tendon morbidity. In this report, we highlight the design, biomechanics, and surgical technique of Achilles tendon reconstruction with Haglund's deformity using a novel technique that utilizes ultrasonic energy to liquefy the suture anchor, allowing it to incorporate into surrounding bone. Biomechanical studies have demonstrated superior strength of the suture anchor utilizing this novel technique as compared with prior techniques. However, future research is needed to ensure that outcomes of this technique are favorable when compared with outcomes using traditional suture anchoring methods. Level V: Operative technique.

  3. Peroneal perforator-based peroneus longus tendon and sural neurofasciocutaneous composite flap transfer for a large soft-tissue defect of the forearm: A case report.

    Science.gov (United States)

    Hayashida, Kenji; Saijo, Hiroto; Fujioka, Masaki

    2018-01-01

    We describe the use of a composite flap composed of a sural neurofasciocutaneous flap and a vascularized peroneus longus tendon for the reconstruction of severe composite forearm tissue defects in a patient. A 43-year-old man had his left arm caught in a conveyor belt resulting in a large soft-tissue defect of 18 × 11 cm over the dorsum forearm. The extensor carpi radialis, superficial radial nerve, and radial artery were severely damaged. A free neurofasciocutaneous composite flap measuring 16 × 11 cm was outlined on the patient's left lower leg to allow simultaneous skin, tendon, nerve, and artery reconstruction. The flap, which included the peroneus longus tendon, was elevated on the subfascial plane. After the flap was transferred to the recipient site, the peroneal artery was anastomosed to the radial artery in a flow-through manner. The vascularized tendon graft with 15 cm in length was used to reconstruct the extensor carpi radialis longus tendon defect using an interlacing suture technique. As the skin paddle of the sural neurofasciocutaneous flap and the vascularized peroneus longus tendon graft were linked by the perforator and minimal fascial tissue, the skin paddle was able to rotate and slide with comparative ease. The flap survived completely without any complications. The length of follow-up was 12 months and was uneventful. Range of motion of his left wrist joint was slightly limited to 75 degrees. This novel composite flap may be useful for reconstructing long tendon defects associated with extensive forearm soft tissue defects. © 2016 Wiley Periodicals, Inc.

  4. Microstructural stress relaxation mechanics in functionally different tendons.

    Science.gov (United States)

    Screen, H R C; Toorani, S; Shelton, J C

    2013-01-01

    Tendons experience widely varying loading conditions in vivo. They may be categorised by their function as either positional tendons, which are used for intricate movements and experience lower stress, or as energy storage tendons which act as highly stressed springs during locomotion. Structural and compositional differences between tendons are thought to enable an optimisation of their properties to suit their functional environment. However, little is known about structure-function relationships in tendon. This study adopts porcine flexor and extensor tendon fascicles as examples of high stress and low stress tendons, comparing their mechanical behaviour at the micro-level in order to understand their stress relaxation response. Stress-relaxation was shown to occur predominantly through sliding between collagen fibres. However, in the more highly stressed flexor tendon fascicles, more fibre reorganisation was evident when the tissue was exposed to low strains. By contrast, the low load extensor tendon fascicles appears to have less capacity for fibre reorganisation or shearing than the energy storage tendon, relying more heavily on fibril level relaxation. The extensor fascicles were also unable to sustain loads without rapid and complete stress relaxation. These findings highlight the need to optimise tendon repair solutions for specific tendons, and match tendon properties when using grafts in tendon repairs. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. Local trauma in human patellar tendon leads to widespread changes in the tendon gene expression

    DEFF Research Database (Denmark)

    Heinemeier, Katja Maria; Lorentzen, Marc P; Kildevang Jensen, Jacob

    2016-01-01

    Low cellular activity and slow tissue turnover in human tendon may prolong resolution of tendinopathy. This may be stimulated by moderate localized traumas such as needle penetrations, but whether this results in a widespread cellular response in tendons is unknown. In an initial hypothesis-gener...

  6. Structural tendon changes in patients with acromegaly: assessment of Achilles tendon with sonoelastography.

    Science.gov (United States)

    Onal, Eda Demil; Ipek, Ali; Evranos, Berna; Idilman, Ilkay Sedakat; Cakir, Bekir; Ersoy, Reyhan

    2016-03-01

    To describe the sonoelastographic appearance of the Achilles tendon in acromegalic patients and to determine whether the blood concentrations of growth hormone (GH) and insulin-like growth factor (IGF-1) are associated with the various sonographic elasticity types of Achilles tendons. Eighty-four Achilles tendons of 42 acromegaly patients and 84 Achilles tendons of 42 healthy volunteers were assessed with sonoelastography. The tendons were classified into two main types according to the elasticity features: type 1 blue/green (hard tissue) and type 2 yellow/red within green (intermediate-soft tissue). Two subtypes of these types were also defined. According to the definition, the elasticity of the tissue was in a spectrum ranging from hard to soft as the type progressed from 1a to 2b. The mean thickness of Achilles tendons in patients with acromegaly was significantly higher compared with healthy Achilles tendons (5.1+/-0.7 mm vs. 4.4+/-0.5, pacromegaly patients had type 2 sonoelastographic appearance of the Achilles tendon (124/252 third; 49.2% vs. 81/252 third; 32.1%, p=0.0001). Activity status of acromegaly and GH/IGF-I levels were similar in patients with different types of elasticity (p>0.05). Sonoelastography revealed structural changes in the tendinous tissue of patients with acromegaly, but it was not sensitive enough to reflect changes in the serum levels of GH/IGF-1.

  7. Histological Changes in the Proximal and Distal Tendon Stumps Following Transection of Achilles Tendon in the Rabbits.

    Science.gov (United States)

    Al-Qattan, Mohammad M; Mawlana, Ola Helmi; Mohammed Ahmed, Raeesa Abdel-Twab; Hawary, Khalid

    2016-05-01

    To determine tendon stump changes following unrepaired Achilles tendon lacerations in an animal model. An experimental study. King Saud University, Riyadh, Saudi Arabia, from October 2013 to January 2014. Arabbit model was developed and studied tendon retraction and histological changes in the proximal and distal stumps following transection of the Achilles tendon. Over a period of 12 weeks, retraction of the distal tendon stump was minimal (2 - 3 mm). In contrast, retraction of the proximal tendon stump peaked to reach 6 mm at 4 weeks post-injury and plateaued to reach 7 - 8 mm at the 12-week interval. Following complete transection of the Achilles tendon, tendon retraction correlated with the density of myofibroblast expression within the tendon stump. Further research is needed to investigate the pathophysiology of these findings.

  8. Histological Changes in the Proximal and Distal Tendon Stumps Following Transection of Achilles Tendon in the Rabbits

    International Nuclear Information System (INIS)

    Al-Qattan, M. M.; Hawary, K.; Mawlana, O. H.; Ahmed, R. A. M.

    2016-01-01

    Objective: To determine tendon stump changes following unrepaired Achilles tendon lacerations in an animal model. Study Design: An experimental study. Place and Duration of Study: King Saud University, Riyadh, Saudi Arabia, from October 2013 to January 2014. Methodology: Arabbit model was developed and studied tendon retraction and histological changes in the proximal and distal stumps following transection of the Achilles tendon. Result: Over a period of 12 weeks, retraction of the distal tendon stump was minimal (2 - 3 mm). In contrast, retraction of the proximal tendon stump peaked to reach 6 mm at 4 weeks post-injury and plateaued to reach 7 - 8 mm at the 12-week interval. Conclusion: Following complete transection of the Achilles tendon, tendon retraction correlated with the density of myofibroblast expression within the tendon stump. Further research is needed to investigate the pathophysiology of these findings. (author)

  9. Extensile posterior approach to the ankle with detachment of the achilles tendon for oncologic indications.

    Science.gov (United States)

    Maheshwari, Aditya V; Walters, Jason A; Henshaw, Robert M

    2012-05-01

    We describe an extensile posterior approach to the ankle with detachment of the Achilles tendon for resection of extensive tumors involving the posterior ankle. To the best of our knowledge, this approach and its results have not been reported for oncologic indications. The surgical technique involved detachment of the Achilles tendon, tumor resection and reconstruction of the Achilles tendon with anchor sutures, and was used in six patients. The diagnosis was pigmented villonodular synovitis (5) and chondroblastoma (1). At a mean of 6 (range, 2 to 10) years followup, all patients were free from tumor. All patients could walk an unlimited amount without any support. There were no problems with Achilles incompetence. The mean Musculoskeletal Tumor Society score was 97 ± 4.2% (range, 90 to 100) and the mean Achilles Tendon Total Rupture Score was 95 ± 5.7 (range, 87 to 100). One patient with screwed suture anchors had backing out of two anchors along with deep infection, requiring surgical debridement and anchor removal. One other patient had a post-traumatic small wound dehiscence which responded to local wound care. Excellent exposure, tumor control and patient function were achieved by this approach in a select group of patients. The surgical technique described in this report offers another alternative for an extensile posterior approach to the ankle and/or subtalar joints.

  10. The use of bovine pericardial patch for vascular reconstruction in infected fields for transplant recipients

    Directory of Open Access Journals (Sweden)

    Sandra Garcia Aroz, MD

    2017-03-01

    Full Text Available Infectious vascular complications affecting transplant recipients may lead to severe morbidity and graft loss. This is a retrospective review of vascular repair with bovine pericardial patch (BPP in infected fields for immunosuppressed patients. BPP was used as either a patch or an interposition graft. Five cases of arterial reconstruction in infected fields using BPP were performed. There were no complications related to bleeding, thrombosis, or recurrent infection. In our limited experience, the use of BPP as a vascular patch is successful, and it represents an alternative when vascular reconstruction is needed in the context of infected fields.

  11. Role of biomechanics in the understanding of normal, injured, and healing ligaments and tendons

    Directory of Open Access Journals (Sweden)

    Jung Ho-Joong

    2009-05-01

    Full Text Available Abstract Ligaments and tendons are soft connective tissues which serve essential roles for biomechanical function of the musculoskeletal system by stabilizing and guiding the motion of diarthrodial joints. Nevertheless, these tissues are frequently injured due to repetition and overuse as well as quick cutting motions that involve acceleration and deceleration. These injuries often upset this balance between mobility and stability of the joint which causes damage to other soft tissues manifested as pain and other morbidity, such as osteoarthritis. The healing of ligament and tendon injuries varies from tissue to tissue. Tendinopathies are ubiquitous and can take up to 12 months for the pain to subside before one could return to normal activity. A ruptured medial collateral ligament (MCL can generally heal spontaneously; however, its remodeling process takes years and its biomechanical properties remain inferior when compared to the normal MCL. It is also known that a midsubstance anterior cruciate ligament (ACL tear has limited healing capability, and reconstruction by soft tissue grafts has been regularly performed to regain knee function. However, long term follow-up studies have revealed that 20–25% of patients experience unsatisfactory results. Thus, a better understanding of the function of ligaments and tendons, together with knowledge on their healing potential, may help investigators to develop novel strategies to accelerate and improve the healing process of ligaments and tendons. With thousands of new papers published in the last ten years that involve biomechanics of ligaments and tendons, there is an increasing appreciation of this subject area. Such attention has positively impacted clinical practice. On the other hand, biomechanical data are complex in nature, and there is a danger of misinterpreting them. Thus, in these review, we will provide the readers with a brief overview of ligaments and tendons and refer them to

  12. Role of biomechanics in the understanding of normal, injured, and healing ligaments and tendons

    Science.gov (United States)

    Jung, Ho-Joong; Fisher, Matthew B; Woo, Savio L-Y

    2009-01-01

    Ligaments and tendons are soft connective tissues which serve essential roles for biomechanical function of the musculoskeletal system by stabilizing and guiding the motion of diarthrodial joints. Nevertheless, these tissues are frequently injured due to repetition and overuse as well as quick cutting motions that involve acceleration and deceleration. These injuries often upset this balance between mobility and stability of the joint which causes damage to other soft tissues manifested as pain and other morbidity, such as osteoarthritis. The healing of ligament and tendon injuries varies from tissue to tissue. Tendinopathies are ubiquitous and can take up to 12 months for the pain to subside before one could return to normal activity. A ruptured medial collateral ligament (MCL) can generally heal spontaneously; however, its remodeling process takes years and its biomechanical properties remain inferior when compared to the normal MCL. It is also known that a midsubstance anterior cruciate ligament (ACL) tear has limited healing capability, and reconstruction by soft tissue grafts has been regularly performed to regain knee function. However, long term follow-up studies have revealed that 20–25% of patients experience unsatisfactory results. Thus, a better understanding of the function of ligaments and tendons, together with knowledge on their healing potential, may help investigators to develop novel strategies to accelerate and improve the healing process of ligaments and tendons. With thousands of new papers published in the last ten years that involve biomechanics of ligaments and tendons, there is an increasing appreciation of this subject area. Such attention has positively impacted clinical practice. On the other hand, biomechanical data are complex in nature, and there is a danger of misinterpreting them. Thus, in these review, we will provide the readers with a brief overview of ligaments and tendons and refer them to appropriate methodologies used to

  13. MR Imaging and US of the Wrist Tendons.

    Science.gov (United States)

    Plotkin, Benjamin; Sampath, Srihari C; Sampath, Srinath C; Motamedi, Kambiz

    2016-10-01

    The tendons of the wrist are commonly symptomatic. They can be injured, infected, or inflamed. Magnetic resonance imaging and ultrasonography are useful tools for evaluating the wrist. Pathologic conditions of the wrist tendons include de Quervain tenosynovitis, extensor carpi ulnaris tendinopathy, rheumatoid tenosynovitis, infectious synovitis, tendon tears, hydroxyapatite deposition disease, intersection syndrome, tenosynovial giant cell tumor, and fibroma of the tendon sheath. In this article, we review the normal appearance of the wrist tendons, discuss relevant anatomy, and give an overview of common pathologic conditions affecting the wrist tendons. Online supplemental material is available for this article. © RSNA, 2016.

  14. FRP tendon anchorage in post-tensioned concrete structures

    DEFF Research Database (Denmark)

    Schmidt, Jacob Wittrup; Täljsten, Björn; Bennitz, Anders

    2008-01-01

    effective Young´s modulus and the high stress capacity in the linear elastic range of the material. The use of external tendons increases the requirements on the anchorage systems. This is in particular important when using un-bonded tendon systems, where the anchorage and deviators are the only force...... transfer points. The demand for high capacity anchorage tendons is fulfilled for steel tendons, but no competitive mechanical anchor has yet been developed for FRP tendon. A new small, reliable and more user friendly anchor has to be developed, before FRP tendons can be utilized with all of its capacity...

  15. Mechanical properties of the human Achilles tendon, in vivo

    DEFF Research Database (Denmark)

    Kongsgaard, M; Nielsen, C H; Hegnsvad, S

    2011-01-01

    Ultrasonography has been widely applied for in vivo measurements of tendon mechanical properties. Assessments of human Achilles tendon mechanical properties have received great interest. Achilles tendon injuries predominantly occur in the tendon region between the Achilles-soleus myotendinous...... junction and Achilles-calcaneus osteotendinous junction i.e. in the free Achilles tendon. However, there has been no adequate ultrasound based method for quantifying the mechanical properties of the free human Achilles tendon. This study aimed to: 1) examine the mechanical properties of the free human...

  16. The effects of low-intensity pulsed ultrasound on tendon-bone healing in a transosseous-equivalent sheep rotator cuff model.

    Science.gov (United States)

    Lovric, Vedran; Ledger, Michael; Goldberg, Jerome; Harper, Wade; Bertollo, Nicky; Pelletier, Matthew H; Oliver, Rema A; Yu, Yan; Walsh, William R

    2013-02-01

    The purpose of this study was to examine the effects Low-intensity Pulsed Ultrasound has on initial tendon-bone healing in a clinically relevant extra-articular transosseous-equivalent ovine rotator cuff model. Eight skeletally mature wethers, randomly allocated to either control group (n = 4) or treatment group (n = 4), underwent rotator cuff surgery following injury to the infraspinatus tendon. All animals were killed 28 days post surgery to allow examination of early effects of Low-intensity Pulsed Ultrasound treatment. General improvement in histological appearance of tendon-bone integration was noted in the treatment group. Newly formed woven bone with increased osteoblast activity along the bone surface was evident. A continuum was observed between the tendon and bone in an interdigitated fashion with Sharpey's fibres noted in the treatment group. Low-intensity Pulsed Ultrasound treatment also increased bone mineral density at the tendon-bone interface (p < 0.01), while immunohistochemistry results revealed an increase in the protein expression patterns of VEGF (p = 0.038), RUNX2 (p = 0.02) and Smad4 (p = 0.05). The results of this study indicate that Low-intensity Pulsed Ultrasound may aid in the initial phase of tendon-bone healing process in patients who have undergone rotator cuff repair. This treatment may also be beneficial following other types of reconstructive surgeries involving the tendon-bone interface.

  17. Optimal arm posture control and tendon traction forces of a coupled tendon-driven manipulator

    International Nuclear Information System (INIS)

    Ma, Shugen

    1997-01-01

    In this study, the optimum arm posture of a coupled tendon-driven multijoint manipulator arm (or CT Arm) at maximum payload output was derived and the corresponding tendon traction forces were also analyzed, during management of a heavy payload by the manipulator in a gravity environment. The CT Arm is special tendon traction transmission mechanism in which a pair of tendons used to drive a joint is pulled from base actuators via pulleys mounted on the base-side joints. This mechanism enables optimal utilization of the coupled drive function of tendon traction forces and thus enables the lightweight manipulator to exhibit large payload capability. The properties of the CT Arm mechanism are elucidated by the proposed optimal posture control scheme. Computer simulation was also executed to verify the validity of the proposed control scheme. (author)

  18. Highly Unusual Tendon Abnormality: Spontaneous Rupture of the Distal Iliopsoas Tendon

    Directory of Open Access Journals (Sweden)

    Gokcen Coban

    2014-06-01

    Full Text Available Iliopsoas tendon injuries are not common and usually occur due to avulsion of the iliopsoas tendon with detachment of the lesser trochanter, secondary to an athletic injury or trauma. In the absence of a trauma, avulsion of the lesser trochanter in an adult is regarded as a sign of metastatic disease until proven otherwise. Complete iliopsoas tendon tears have thus far only been described in elderly women, and without trauma or an underlying systemic disease, a hormonal basis may be a reason for the gender differences. In this article, we present an 87-year-old woman with spontaneous rupture of the left distal iliopsoas tendon unassociated with fracture of the lesser trochanter and in the absence of a recent trauma history. This elderly patient presented with acute groin pain and normal plain radiographs. Magnetic resonance imaging must be kept in mind as a modality of choice for identifying iliopsoas tendon abnormalities.

  19. Effect of cyclic training model on terminal structure of rabbit Achilles tendon: an experimental study

    Directory of Open Access Journals (Sweden)

    Chang-lin HUANG

    2012-05-01

    group at the early stage, but there was an increase at the late stage of the training (6 weeks later, however the score values were lower than those in the jumping group and running group. These changes in score were originated mainly from pathological changes in the paratenon and tidemark. Conclusions  Jumping training could lead to severe injury to the fiber tissue and fibrocartilage, while running training might result in severe injury to Achilles tendon insertion structure and lighter injury to the fibrocartilage part. Cyclic training model provides suffcient time for repair and reconstruction of Achilles tendon insertion structure, and decrease the severity of the injury to Achilles tendon insertion region. Therefore, use of cyclic training could not only effectively prevent training-based enthesiopathy, but also accelerate the remodeling of the tissue in the insertion region, thus strengthen the repair ability of Achilles tendon against injury.

  20. Treatment of peroneal tendon dislocation and coexisting medial and lateral ligamentous laxity in the ankle joint.

    Science.gov (United States)

    Ziai, Pejman; Sabeti-Aschraf, Manuel; Fehske, Kai; Dlaska, Constantin E; Funovics, Philipp; Wenzel, Florian; Graf, Alexandra; Buchhorn, Tomas

    2011-06-01

    Acute dislocation of the peroneal tendon is caused by massive combined flexion-torsion trauma supported by preexisting ligamentous laxity of the ankle joint. This study aimed to investigate the clinical outcome of combined treatment of peroneal tendon dislocation and lateral and medial ligamentous laxity. Between 2005 and 2007, forty-two patients with peroneal tendon dislocation and coexisting ligamentous laxity were treated. The superior extensor retinaculum was reconstructed using anchor technique and periosteal flap repair, whereas the preexisting ligamentous laxity with regard to the extensor inferior retinaculum was addressed using anchor reconstruction. All patients underwent arthroscopy prior to surgery. Thirty-eight of a total of 42 patients (aged 17-31) completed the 24-month follow-up. Clinical and arthroscopic examination was accomplished consistently by always the same two surgeons. Postoperative follow-up comprised clinical evaluation after 3, 6, 12 and 24 months. Clinical results showed a significant (Pankle joint following arthroscopy results in good clinical outcome and high patient satisfaction. Case series, Level IV.

  1. No Telescoping Effect with Dual Tendon Vibration.

    Directory of Open Access Journals (Sweden)

    Valeria Bellan

    Full Text Available The tendon vibration illusion has been extensively used to manipulate the perceived position of one's own body part. However, findings from previous research do not seem conclusive sregarding the perceptual effect of the concurrent stimulation of both agonist and antagonist tendons over one joint. On the basis of recent data, it has been suggested that this paired stimulation generates an inconsistent signal about the limb position, which leads to a perceived shrinkage of the limb. However, this interesting effect has never been replicated. The aim of the present study was to clarify the effect of a simultaneous and equal vibration of the biceps and triceps tendons on the perceived location of the hand. Experiment 1 replicated and extended the previous findings. We compared a dual tendon stimulation condition with single tendon stimulation conditions and with a control condition (no vibration on both 'upward-downward' and 'towards-away from the elbow' planes. Our results show a mislocalisation towards the elbow of the position of the vibrated arm during dual vibration, in line with previous results; however, this did not clarify whether the effect was due to arm representation contraction (i.e., a 'telescoping' effect. Therefore, in Experiment 2 we investigated explicitly and implicitly the perceived arm length during the same conditions. Our results clearly suggest that in all the vibration conditions there was a mislocalisation of the entire arm (including the elbow, but no evidence of a contraction of the perceived arm length.

  2. management of open achilles tendon injury: primary repair and early ...

    African Journals Online (AJOL)

    is attributable to increase in both competitive and recreational sports. In most of the literature written on Achilles tendon injuries there were rarely any information about open Achilles tendon ... The most common aetiology was motorbike spoke.

  3. Robot Arm with Tendon Connector Plate and Linear Actuator

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor); Bridgwater, Lyndon (Inventor); Nguyen, Vienny (Inventor); Millerman, Alexander (Inventor)

    2014-01-01

    A robotic system includes a tendon-driven end effector, a linear actuator, a flexible tendon, and a plate assembly. The linear actuator assembly has a servo motor and a drive mechanism, the latter of which translates linearly with respect to a drive axis of the servo motor in response to output torque from the servo motor. The tendon connects to the end effector and drive mechanism. The plate assembly is disposed between the linear actuator assembly and the tendon-driven end effector and includes first and second plates. The first plate has a first side that defines a boss with a center opening. The second plate defines an accurate through-slot having tendon guide channels. The first plate defines a through passage for the tendon between the center opening and a second side of the first plate. A looped end of the flexible tendon is received within the tendon guide channels.

  4. Intraoperative extracorporeal autogenous irradiated tendon grafts for functional limb salvage surgery of soft tissue sarcomas of the wrist and hand.

    Science.gov (United States)

    Omori, Shinsuke; Hamada, Kenichiro; Outani, Hidetatsu; Oshima, Kazuya; Joyama, Susumu; Tomita, Yasuhiko; Naka, Norifumi; Araki, Nobuhito; Yoshikawa, Hideki

    2015-05-12

    In patients with soft tissue sarcoma of the wrist and hand, limb salvage operation is extremely challenging for surgeons in attempting a complete tumor resection with negative surgical margins. In this study, we report four patients with soft tissue sarcoma of the wrist and hand treated by limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts. The patients were all male, and the mean age at the time of surgery was 45 years. Histological diagnoses included clear cell sarcoma in two patients, synovial sarcoma in one, and angiosarcoma in one. All four patients had high grade tumors, wherein three had American Joint Committee on Cancer (AJCC) stage III disease and one with AJCC stage IV disease. The tumors were resected en bloc with involved tendons. The tendons were isolated from the resected tissues, irradiated ex vivo, and re-implanted into the host tendons. In one patient, the bone was resected additionally because of tumor invasion to the bone. Hand function was evaluated using Musculoskeletal Tumor Society (MSTS) rating system. Of the four patients, three died of distant metastatic disease. The remaining patient lives and remains disease-free. The mean follow-up period was 33 months. One patient had local recurrence outside the irradiated graft at 20 months after surgery. The functional rating was 22. Lower scores were seen in patients with reconstruction of flexor tendons than extensor tendons. Limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts is an acceptable method in selected patients with soft tissue sarcoma of the wrist and hand.

  5. Establishment of a rat and guinea pig aortic interposition graft model reveals model-specific patterns of intimal hyperplasia.

    Science.gov (United States)

    Gregory, Elaine K; Vercammen, Janet M; Flynn, Megan E; Kibbe, Melina R

    2016-12-01

    Although the aortic interposition bypass model has been widely used to evaluate biomaterials for bypass grafting, there is no comprehensive description of the procedure or of the distribution of intimal hyperplasia that results. The objectives of this study were to (1) review and summarize approaches of aortic interposition grafting in animal models, (2) determine the pertinent anatomy for this procedure, (3) validate this model in the rat and guinea pig, and (4) compare the distribution of intimal hyperplasia that develops in each species. A literature search was performed in PubMed from 1980 to the present to analyze the use of anesthesia, anticoagulation, antiplatelet agents, graft material, suture, and anastomotic techniques. Using 10-week-old male Sprague-Dawley rats and Hartley guinea pigs, we established pertinent aortic anatomy, developed comparable models, and assessed complications for each model. At 30 days, the graft and associated aorta were explanted, intimal formation was assessed morphometrically, and cellularity was assessed via nuclear counting. We reviewed 30 articles and summarized the pertinent procedural findings. Upon establishing both animal models, key anatomic differences between the species that affect this model were noted. Guinea pigs have a much larger cecum, increased retroperitoneal fat, and lack the iliolumbar vessels compared with the rat. Surgical outcomes for the rat model included a 53% technical success rate and a 32% technical error rate. Surgical outcomes for the guinea pig model included a 69% technical success rate and a 31% technical error rate. These two species demonstrated unique distribution of intimal hyperplasia at 30 days. Intimal hyperplasia in the rat model was greatest at two areas, the proximal graft (5400 μm 2 ; P guinea pig model developed similar intimal hyperplasia throughout the graft (4500-5100 μm 2 ; P guinea pig, and describe a unique distribution of intimal formation that results in both species

  6. Longitudinal Long-term Magnetic Resonance Imaging and Clinical Follow-up After Single-Row Arthroscopic Rotator Cuff Repair: Clinical Superiority of Structural Tendon Integrity.

    Science.gov (United States)

    Heuberer, Philipp R; Smolen, Daniel; Pauzenberger, Leo; Plachel, Fabian; Salem, Sylvia; Laky, Brenda; Kriegleder, Bernhard; Anderl, Werner

    2017-05-01

    The number of arthroscopic rotator cuff surgeries is consistently increasing. Although generally considered successful, the reported number of retears after rotator cuff repair is substantial. Short-term clinical outcomes are reported to be rarely impaired by tendon retears, whereas to our knowledge, there is no study documenting long-term clinical outcomes and tendon integrity after arthroscopic rotator cuff repair. To investigate longitudinal long-term repair integrity and clinical outcomes after arthroscopic rotator cuff reconstruction. Case series; Level of evidence, 4. Thirty patients who underwent arthroscopic rotator cuff repair with suture anchors for a full-tendon full-thickness tear of the supraspinatus or a partial-tendon full-thickness tear of the infraspinatus were included. Two and 10 years after initial arthroscopic surgery, tendon integrity was analyzed using magnetic resonance imaging (MRI). The University of California, Los Angeles (UCLA) score and Constant score as well as subjective questions regarding satisfaction with the procedure and return to normal activity were used to evaluate short- and long-term outcomes. At the early MRI follow-up, 42% of patients showed a full-thickness rerupture, while 25% had a partial rerupture, and 33% of tendons remained intact. The 10-year MRI follow-up (129 ± 11 months) showed 50% with a total rerupture, while the other half of the tendons were partially reruptured (25%) or intact (25%). The UCLA and Constant scores significantly improved from preoperatively (UCLA total: 50.6% ± 20.2%; Constant total: 44.7 ± 10.5 points) to 2 years (UCLA total: 91.4% ± 16.0% [ P rotator cuff repair showed good clinical long-term results despite a high rate of retears. Nonetheless, intact tendons provided significantly superior clinical long-term outcomes, making the improvement of tendon healing and repair integrity important goals of future research efforts.

  7. Partial tear of the quadriceps tendon in a child

    International Nuclear Information System (INIS)

    Khanna, Geetika; El-Khoury, George

    2008-01-01

    We present a case of partial rupture of the quadriceps tendon in an 8-year-old girl. This is one of the youngest patients reported with a quadriceps tendon rupture, an entity seen predominantly in middle-aged people. The strength of the muscle tendon unit in a child makes tendon injuries extremely unusual as compared to apophyseal avulsions. The MR imaging findings of this unusual pediatric injury are illustrated. (orig.)

  8. Calcaneal tendon: imaging findings; Tendao calcaneo: avaliacao por imagem

    Energy Technology Data Exchange (ETDEWEB)

    Montandon, Cristiano; Fonseca, Cristiano Rezio; Montandon Junior, Marcelo Eustaquio [Colegio Brasileiro de Radiologia e Diagnostico por Imagem, Sao Paulo, SP (Brazil)]. E-mail: crismontandon@hotmail.com; Lobo, Leonardo Valadares; Ribeiro, Flavia Aparecida de Souza; Teixeira, Kim-Ir-Sen Santos [Goias Univ., Goiania, GO (Brazil). Hospital de Clinicas. Dept. de Diagnostico por Imagem e Anatomia Patologica

    2003-12-01

    We reviewed the radiological and clinical features of 23 patients with calcaneal tendon diseases, who were submitted to ultrasound or magnetic resonance imaging. The objective of this study was to characterize the lesions for a precise diagnosis of calcaneal tendon injuries. A wide range of calcaneal tendon diseases include degenerative lesions, inflammation of the peritendinous tissue such as peritendinitis and bursitis, and rupture. Imaging methods are essential in the diagnosis, treatment and follow-up of calcaneal tendon diseases. (author)

  9. MRI in flexor tendon rupture after collagenase injection

    International Nuclear Information System (INIS)

    Khurana, Shruti; Wadhwa, Vibhor; Chhabra, Avneesh; Amirlak, Bardia

    2017-01-01

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  10. p38 MAPK signaling in postnatal tendon growth and remodeling.

    Directory of Open Access Journals (Sweden)

    Andrew J Schwartz

    Full Text Available Tendon is a dynamic tissue whose structure and function is influenced by mechanical loading, but little is known about the fundamental mechanisms that regulate tendon growth and remodeling in vivo. Data from cultured tendon fibroblasts indicated that the p38 MAPK pathway plays an important role in tendon fibroblast proliferation and collagen synthesis in vitro. To gain greater insight into the mechanisms of tendon growth, and explore the role of p38 MAPK signaling in this process, we tested the hypotheses that inducing plantaris tendon growth through the ablation of the synergist Achilles tendon would result in rapid expansion of a neotendon matrix surrounding the original tendon, and that treatment with the p38 MAPK inhibitor SB203580 would prevent this growth. Rats were treated with vehicle or SB203580, and subjected to synergist ablation by bilateral tenectomy of the Achilles tendon. Changes in histological and biochemical properties of plantaris tendons were analyzed 3, 7, or 28 days after overload, and comparisons were made to non-overloaded animals. By 28 days after overload, tendon mass had increased by 30% compared to non-overloaded samples, and cross-sectional area (CSA increased by around 50%, with most of the change occurring in the neotendon. The expansion in CSA initially occurred through the synthesis of a hyaluronic acid rich matrix that was progressively replaced with mature collagen. Pericytes were present in areas of active tendon growth, but never in the original tendon ECM. Inhibition of p38 MAPK resulted in a profound decrease in IL6 expression, and had a modest effect on the expression of other ECM and cell proliferation genes, but had a negligible impact on overall tendon growth. The combined results from this study provided novel insights into tendon mechanobiology, and suggest that p38 MAPK signaling does not appear to be necessary for tendon growth in vivo.

  11. MRI in flexor tendon rupture after collagenase injection

    Energy Technology Data Exchange (ETDEWEB)

    Khurana, Shruti [Lady Hardinge Medical College, New Delhi (India); Wadhwa, Vibhor [University of Arkansas for Medical Sciences, Little Rock, AR (United States); Chhabra, Avneesh [UT Southwestern Medical Center, Dallas, TX (United States); Johns Hopkins University, Baltimore, MD (United States); Amirlak, Bardia [UT Southwestern Medical Center, Dallas, TX (United States)

    2017-02-15

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  12. In vitro and in vivo effects of PDGF-BB delivery strategies on tendon healing: a review

    Directory of Open Access Journals (Sweden)

    O Evrova

    2017-07-01

    Full Text Available To promote and support tendon healing, one viable strategy is the use or administration of growth factors at the wound/rupture site. Platelet derived growth factor-BB (PDGF-BB, together with other growth factors, is secreted by platelets after injury. PDGF-BB promotes mitogenesis and angiogenesis, which could accelerate tendon healing. Therefore, in vitro studies with PDGF-BB have been performed to determine its effect on tenocytes and tenoblasts. Moreover, accurate and sophisticated drug delivery devices, aiming for a sustained release of PDGF-BB, have been developed, either by using heparin-binding and fibrin-based matrices or different electrospinning techniques. In this review, the structure and composition, as well as the healing process of tendons, are described. Part A deals with in vitro studies. They focus on the multiple effects evoked by PDGF-BB on the cellular level. Moreover, they address strategies for the sustained delivery of PDGF-BB. Part B focuses on animal models used to test different delivery strategies for PDGF-BB, in the context of tendon reconstruction. These studies showed that dosage and timing of PDGF-BB application are the most important factors for deciding which delivery device should be applied for a specific tendon laceration.

  13. PERONEAL TENDON LESIONS IN ATHLETES (REVIEW

    Directory of Open Access Journals (Sweden)

    E. E. Achkasov

    2016-01-01

    Full Text Available The authors analyzed scientific literature in respect of various issues in treatment of athletes with peroneal muscles lesions starting from 1987 till 2016. Key search and publications selection was made in PubMed and russian national electronic scientific library eLIBRARY. Peroneal tendons pathology is not the major but the underestimated cause of pain in lateral and hindfoot as well as of foot dysfunction which is difficult to distinguish from lesions of lateral ligaments of the ankle joint. Untreated lesions of peroneal tendons can result in chronic ankle pain and significant functional disorders. The purpose of the present paper is to improve the current comprehension of anatomy, to identify factors contributing to pathology, to perform diagnostic evaluation of peroneal tendons and to review current treatment options of such lesions.

  14. Triple Achilles Tendon Rupture: Case Report.

    Science.gov (United States)

    Saxena, Amol; Hofer, Deann

    We present a case report with 1-year follow-up data of a 57-year-old male soccer referee who had sustained an acute triple Achilles tendon rupture injury during a game. His triple Achilles tendon rupture consisted of a rupture of the proximal watershed region, a rupture of the main body (mid-watershed area), and an avulsion-type rupture of insertional calcific tendinosis. The patient was treated surgically with primary repair of the tendon, including tenodesis with anchors. Postoperative treatment included non-weightbearing for 4 weeks and protected weightbearing until 10 weeks postoperative, followed by formal physical therapy, which incorporated an "antigravity" treadmill. The patient was able to return to full activity after 26 weeks, including running and refereeing, without limitations. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Lateral force transmission between human tendon fascicles

    DEFF Research Database (Denmark)

    Haraldsson, Bjarki T; Aagaard, Per; Qvortrup, Klaus

    2008-01-01

    Whether adjacent collagen fascicles transmit force in parallel is unknown. The purpose of the present study was to examine the magnitude of lateral force transmission between adjacent collagen fascicles from the human patellar and Achilles tendon. From each sample two adjacent strands of fascicles...... was transversally cut while the other fascicle and the fascicular membrane were kept intact. Cycle 3: both fascicles were cut in opposite ends while the fascicular membrane was left intact. A decline in peak force of 45% and 55% from cycle 1 to cycle 2, and 93% and 92% from cycle 2 to cycle 3 was observed...... in the patellar and Achilles tendon fascicles, respectively. A decline in stiffness of 39% and 60% from cycle 1 to cycle 2, and of 93% and 100% from cycle 2 to cycle 3 was observed in the patellar and Achilles tendon fascicles, respectively. The present data demonstrate that lateral force transmission between...

  16. Flexor digitorum profundus tendon anatomy in the forearm

    Directory of Open Access Journals (Sweden)

    Teoman Dogan

    2012-04-01

    Methods: We used 11 forearms belonging to cadavers and fixed with formaldehyde. The forearms numbered 1, 2, 8, 9, 10, 11 were the left and right arms of the same cadavers. Those numbered 3, 4, 5, 6, 7 belonged to different cadavers. Dissections were made by using the atraumatic surgical technique. The tendons were studied to identify the structure and number of the fibers forming them. Results: The presence of a large common tendon was found in 10 of the 11 forearms. In 4 of these, the common tendon included the tendons of all four fingers. While the common tendon included 3 fingers in four forearms, it only included tendons belonging to 2 fingers in two forearms. It was not possible in one forearm to separate the common tendon into its fibers. In another forearm, tendons belonging to each digit were separate and independent starting at the muscle-tendon junction to the attachment points. Conclusion: The majority of the cadaver forearms used in the study displayed a single large FDP tendon in the zone between the muscle-tendon joint to the carpal tunnel entry prior to being distributed into each index. This anatomical feature should be considered in choosing materials and surgical technique for Zone V FDP tendon injuries, as well as in planning the rehabilitation process. [Hand Microsurg 2012; 1(1.000: 25-29

  17. Simultaneous bilateral distal biceps tendon rupture during a preacher curl exercise: a case report.

    Science.gov (United States)

    Rokito, Andrew S; lofin, Ilya

    2008-01-01

    Complete rupture of the distal biceps tendon is a rare injury, the overwhelming majority occurring in the dominant arm of males during the fourth to sixth decades of life. Simultaneous bilateral rupture of the distal biceps tendon is an extremely rare occurrence, with only three cases reported in the literature. This unusual injury occurred in a recreational weightlifter during a preacher curl exercise. In this particular case, a 6-week delay in presentation necessitated a staged procedure in which a primary repair was feasible in one elbow, while reconstruction using allograft tissue was required in the contralateral elbow. Satisfactory results for both elbows were achieved, with return to weightlifting by one year following surgery.

  18. Ultrasound diagnostics of muscle and tendon injuries

    Directory of Open Access Journals (Sweden)

    Stević Ruža

    2009-01-01

    Full Text Available Introduction. Sonography is a useful technique for the investigation of a number of musculoskeletal disorders. The most common indication for ultrasonography of muscles and tendons is the diagnosis of traumatic lesions, distinguishing them from other disorders and follow-up of healing process. Objective. The purpose of this paper is to show the importance of ultrasound in the diagnosis of muscle and tendon injuries. Methods. The study included 170 patients (148 male and 22 female, mean age 29.6 years (range 14-60 years. All examinations were performed by linear transducer of 7.5-10 MHz, with longitudinal and transverse scanning. Ultrasound examination followed physical examination. Results. Traumatic lesions of muscles were diagnosed in 113 patients (66.7% and tendon injuries in 57 cases (33.2%. The muscle changes detected by ultrasonography were the following: 70 (61.9% partial and two (1.76% complete ruptures, 22 (19.46% haematoma, 9 (7.96% strains grade I, 4 fibroses and 4 ossifying myositis 4 (3.5%, respectively. Complications of muscle injuries were diagnosed in two cases, a muscular hernia and an arteriovenous fistula. Among tendon injuries, 21 (33.8% ruptures and 36 (66.1% tendinitis were diagnosed. Accompanying effusion in the bursa of patients with tendon injuries was found in 9 cases. Conclusion. Ultrasonography allowed visualization and objective assessment of the type and the extent of traumatic pathomorphological changes of muscles and tendons. Such diagnostic possibilities of ultrasonography are especially important in the choice of appropriate therapy.

  19. Spontaneous Achilles tendon rupture in alkaptonuria

    Directory of Open Access Journals (Sweden)

    Omar A. Alajoulin

    2015-12-01

    Full Text Available Alkaptonuria (AKU is a rare inborn metabolic disease characterized by accumulation of homogentisic acid (HGA. Excretion of HGA in urine causes darkening of urine and its deposition in connective tissues causes dark pigmentation (ochronosis, early degeneration of articular cartilage, weakening of the tendons, and subsequent rupture. In this case report, we present a rare case of a patient presented with unilateral spontaneous rupture of Achilles tendon due to AKU. The patient developed most of the orthopedic manifestations of the disease earlier than typical presentations. Alkaptonuria patients should avoid strenuous exercises and foot straining especially in patients developing early orthopedic manifestations.

  20. Spontaneous Achilles tendon rupture in alkaptonuria.

    Science.gov (United States)

    Alajoulin, Omar A; Alsbou, Mohammed S; Ja'afreh, Somayya O; Kalbouneh, Heba M

    2015-12-01

    Alkaptonuria (AKU) is a rare inborn metabolic disease characterized by accumulation of homogentisic acid (HGA). Excretion of HGA in urine causes darkening of urine and its deposition in connective tissues causes dark pigmentation (ochronosis), early degeneration of articular cartilage, weakening of the tendons, and subsequent rupture. In this case report, we present a rare case of a patient presented with unilateral spontaneous rupture of Achilles tendon due to AKU. The patient developed most of the orthopedic manifestations of the disease earlier than typical presentations. Alkaptonuria patients should avoid strenuous exercises and foot straining especially in patients developing early orthopedic manifestations.

  1. [Development of Achilles tendon rupture in skiing].

    Science.gov (United States)

    Suckert, K; Benedetto, K P; Vogel, A

    1983-06-01

    This is an analysis of decline of rupture of the Achilles tendon in skiing while there is a steady increase of skiing injuries. Three groups, equipped with three different types of ski boots were observed once on a plane slope on the other hand on a bump track. The simultaneous size of angle of knee and ankle was measured by telemetry. The high plastic ski boot, which obstructs the ankle forward and lateral is apart from the rise of heel in the boot, the safety binding and the new skiing style the main reason for decline of rupture of the Achilles tendon in skiing.

  2. Xenogenic extracellular matrices as potential biomaterials for interposition grafting in urological surgery.

    LENUS (Irish Health Repository)

    Davis, N F

    2012-01-31

    PURPOSE: The field of tissue engineering focuses on developing strategies for reconstructing injured, diseased, and congenitally absent tissues and organs. During the last decade urologists have benefited from remodeling and regenerative properties of bioscaffolds derived from xenogenic extracellular matrices. We comprehensively reviewed the current literature on structural and functional characteristics of xenogenic extracellular matrix grafting since it was first described in urological surgery. We also reviewed the clinical limitations, and assessed the potential for safe and effective urological application of extracellular matrix grafting in place of autogenous tissue. MATERIALS AND METHODS: We performed literature searches for English language publications using the PubMed(R) and MEDLINE(R) databases. Keywords included "xenogenic," "extracellular matrix" and "genitourinary tract applications." A total of 112 articles were scrutinized, of which 50 were suitable for review based on clinical relevance and importance of content. RESULTS: Since the mid 1990s xenogenic extracellular matrices have been used to successfully treat a number of pathological conditions that affect the upper and lower genitourinary tract. They are typically prepared from porcine organs such as small intestine and bladder. These organs are harvested and subjected to decellularization and sterilization techniques before surgical implantation. Bioinductive growth factors that are retained during the preparation process induce constructive tissue remodeling as the extracellular matrix is simultaneously degraded and excreted. However, recent documented concerns over durability, decreased mechanical strength and residual porcine DNA after preparation techniques have temporarily hampered the potential of extracellular matrices as a reliable replacement for genitourinary tract structures. CONCLUSIONS: Extracellular matrices are a useful alternative for successfully treating a number of urological

  3. Evidence-Based ACL Reconstruction

    Directory of Open Access Journals (Sweden)

    E. Carlos RODRIGUEZ-MERCHAN

    2015-01-01

    Full Text Available There is controversy in the literature regarding a number of topics related to anterior cruciate ligament (ACLreconstruction. The purpose of this article is to answer the following questions: 1 Bone patellar tendon bone (BPTB reconstruction or hamstring reconstruction (HR; 2 Double bundle or single bundle; 3 Allograft or authograft; 4 Early or late reconstruction; 5 Rate of return to sports after ACL reconstruction; 6 Rate of osteoarthritis after ACL reconstruction. A Cochrane Library and PubMed (MEDLINE search of systematic reviews and meta-analysis related to ACL reconstruction was performed. The key words were: ACL reconstruction, systematic reviews and meta-analysis. The main criteria for selection were that the articles were systematic reviews and meta-analysesfocused on the aforementioned questions. Sixty-nine articles were found, but only 26 were selected and reviewed because they had a high grade (I-II of evidence. BPTB-R was associated with better postoperative knee stability but with a higher rate of morbidity. However, the results of both procedures in terms of functional outcome in the long-term were similar. The double-bundle ACL reconstruction technique showed better outcomes in rotational laxity, although functional recovery was similar between single-bundle and double-bundle. Autograft yielded better results than allograft. There was no difference between early and delayed reconstruction. 82% of patients were able to return to some kind of sport participation. 28% of patients presented radiological signs of osteoarthritis with a follow-up of minimum 10 years.

  4. Magnetic resonance evaluation of anterior cruciate ligament repair using the patellar tendon double bone block technique

    International Nuclear Information System (INIS)

    Autz, G.; Singson, R.D.; Goodwin, C.

    1991-01-01

    The magnetic resonance (MR) appearance of the anterior cruciate ligament reconstruction was determined in 20 clinically stable and 2 clinically unstable knees for a total of 22 examinations. All patients studied had undergone knee reconstruction using the patellar tendon as graft material. The reconstructed anterior cruciate ligament varies in appearance. It appeared as a thick, well-defined, low signal band on T1- and T2-weighted sagittal and coronal images in 14 of 22 examinations. The remaining 8 knees showed a graft having one or more thin and attenuated, low signal intensity bands in the sagittal and/or coronal plane. Arthroscopy confirmed an intact but lax graft in the clinically unstable knees. (orig.)

  5. Magnetic resonance evaluation of anterior cruciate ligament repair using the patellar tendon double bone block technique

    Energy Technology Data Exchange (ETDEWEB)

    Autz, G.; Singson, R.D. (St. Luke' s Roosevelt Hospital Center, New York, NY (United States). Dept. of Radiology); Goodwin, C. (St. Luke' s Roosevelt Hospital Center, New York, NY (United States). Dept. of Orthopedics)

    1991-11-01

    The magnetic resonance (MR) appearance of the anterior cruciate ligament reconstruction was determined in 20 clinically stable and 2 clinically unstable knees for a total of 22 examinations. All patients studied had undergone knee reconstruction using the patellar tendon as graft material. The reconstructed anterior cruciate ligament varies in appearance. It appeared as a thick, well-defined, low signal band on T1- and T2-weighted sagittal and coronal images in 14 of 22 examinations. The remaining 8 knees showed a graft having one or more thin and attenuated, low signal intensity bands in the sagittal and/or coronal plane. Arthroscopy confirmed an intact but lax graft in the clinically unstable knees. (orig.).

  6. Peroneal tendon displacement accompanying intra-articular calcaneal fractures.

    Science.gov (United States)

    Toussaint, Rull James; Lin, Darius; Ehrlichman, Lauren K; Ellington, J Kent; Strasser, Nicholas; Kwon, John Y

    2014-02-19

    Peroneal tendon displacement (subluxation or dislocation) accompanying an intra-articular calcaneal fracture is often undetected and under-treated. The goals of this study were to determine (1) the prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures, (2) the association of tendon displacement with fracture classifications, (3) the association of tendon displacement with heel width, and (4) the rate of missed diagnosis of the tendon displacement on radiographs and computed tomography (CT) scans and the resulting treatment rate. A retrospective radiographic review of all calcaneal fractures presenting at three institutions from June 30, 2006, to June 30, 2011, was performed. CT imaging of 421 intra-articular calcaneal fractures involving the posterior facet was available for review. The prevalence of peroneal tendon displacement was noted and its associations with fracture classification and heel width were evaluated. Peroneal tendon displacement was identified in 118 (28.0%) of the 421 calcaneal fracture cases. The presence of tendon displacement was significantly associated with joint-depression fractures compared with tongue-type fractures (p displacement had been identified in the radiology reports. Although sixty-five (55.1%) of the fractures with tendon displacement had been treated with internal fixation, the tendon displacement was treated surgically in only seven (10.8%) of these cases. Analysis of CT images showed a 28% prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures. Surgeons and radiologists are encouraged to consider this association.

  7. Plantar tendons of the foot: MR imaging and US.

    Science.gov (United States)

    Donovan, Andrea; Rosenberg, Zehava Sadka; Bencardino, Jenny T; Velez, Zoraida Restrepo; Blonder, David B; Ciavarra, Gina A; Adler, Ronald Steven

    2013-01-01

    Tendon disorders along the plantar aspect of the foot may lead to significant symptoms but are often clinically misdiagnosed. Familiarity with the normal anatomy of the plantar tendons and its appearance at magnetic resonance (MR) imaging and ultrasonography (US) is essential for recognizing plantar tendon disorders. At MR imaging, the course of the plantar tendons is optimally visualized with dedicated imaging of the midfoot and forefoot. This imaging should include short-axis images obtained perpendicular to the long axis of the metatarsal shafts, which allows true cross-sectional evaluation of the plantar tendons. Normal plantar tendons appear as low-signal-intensity structures with all MR sequences. At US, accurate evaluation of the tendons requires that the ultrasound beam be perpendicular to the tendon. The normal tendon appears as a compact linear band of echogenic tissue that contains a fine, mixed hypoechoic and hyperechoic internal fibrillar pattern. Tendon injuries can be grouped into six major categories: tendinosis, peritendinosis, tenosynovitis, entrapment, rupture, and instability (subluxation or dislocation) and can be well assessed with both MR imaging and US. The radiologist plays an important role in the diagnosis of plantar tendon disorders, and recognizing their imaging appearances at MR imaging and US is essential.

  8. A Rare Case of Simultaneous Acute Bilateral Quadriceps Tendon Rupture and Unilateral Achilles Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Wei Yee Leong

    2013-07-01

    Full Text Available Introduction: There have been multiple reported cases of bilateral quadriceps tendon ruptures (QTR in the literature. These injuries frequently associated with delayed diagnosis, which results in delayed surgical treatment. In very unusual cases, bilateral QTRs can be associated with other simultaneous tendon ruptures. Case Report: We present a rare case of bilateral QTR with a simultaneous Achilles Tendon Rupture involving a 31 years old Caucasian man who is a semi-professional body builder taking anabolic steroids. To date bilateral QTR with additional TA rupture has only been reported once in the literature and to our knowledge this is the first reported case of bilateral QTR and simultaneous TA rupture in a young, fit and healthy individual. Conclusion: The diagnosis of bilateral QTR alone can sometimes be challenging and the possibility of even further tendon injuries should be carefully assessed. A delay in diagnosis could result in delay in treatment and potentially worse outcome for the patient. Keywords: Quadriceps tendon rupture; Achilles tendon rupture; Bilateral.

  9. Tendoscopy of the posterior tibial tendon

    NARCIS (Netherlands)

    van Dijk, C. N.; Kort, N.; Scholten, P. E.

    1997-01-01

    An anatomic cadaver study was performed and subsequently, in a prospective study, diagnostic and therapeutic tendoscopy (tendon sheath endoscopy) was performed in 16 consecutive patients with a history of persistent posteromedial ankle pain for at least 6 months. All patients had pain on palpation

  10. A posterior tibial tendon skipping rope

    NARCIS (Netherlands)

    van Sterkenburg, M. N.; Haverkamp, D.; van Dijk, C. N.; Kerkhoffs, G. M. M. J.

    2010-01-01

    This report presents an athletic patient with swelling and progressive pain on the posteromedial side of his right ankle on weight bearing. MRI demonstrated tenosynovitis and suspicion of a length rupture. On posterior tibial tendoscopy, there was no rupture, but medial from the tendon a tissue cord

  11. Radiographic Features of Acute Patellar Tendon Rupture.

    Science.gov (United States)

    Fazal, Muhammad Ali; Moonot, Pradeep; Haddad, Fares

    2015-11-01

    The purpose of our study was to assess soft tissue features of acute patellar tendon rupture on lateral knee radiograph that would facilitate early diagnosis. The participants were divided into two groups of 35 patients each. There were 28 men and seven women with a mean age of 46 years in the control group and 26 men and nine women with a mean age of 47 years in the rupture group. The lateral knee radiograph of each patient was evaluated for Insall-Salvati ratio for patella alta, increased density of the infrapatellar fat pad, appearance of the soft tissue margin of the patellar tendon and bony avulsions. In the rupture group there were three consistent soft tissue radiographic features in addition to patellar alta. These were increased density of infrapatellar fat pad; loss of sharp, well-defined linear margins of the patellar tendon and angulated wavy margin of the patellar tendon while in the control group these features were not observed. The soft tissue radiographic features described in the rupture group are consistent and reliable. When coupled with careful clinical assessment, these will aid in early diagnosis and further imaging will be seldom required. © 2015 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  12. Engaging Stem Cells for Customized Tendon Regeneration

    Directory of Open Access Journals (Sweden)

    Hatim Thaker

    2012-01-01

    Full Text Available The need for a consistent therapeutic approach to tendon injury repair is long overdue. Patients with tendon microtears or full ruptures are eligible for a wide range of invasive and non invasive interventions, often subjectively decided by the physician. Surgery produces the best outcomes, and while studies have been conducted to optimize graft constructs and to track outcomes, the data from these studies have been inconclusive on the whole. What has been established is a clear understanding of healthy tendon architecture and the inherent process of healing. With this knowledge, tissue regeneration efforts have achieved immense progress in scaffold design, cell line selection, and, more recently, the appropriate use of cytokines and growth factors. This paper evaluates the plasticity of bone-marrow-derived stem cells and the elasticity of recently developed biomaterials towards tendon regeneration efforts. Mesenchymal stem cells (MSCs, hematopoietic progenitor cells, and poly(1,8-octanediol co-citrate scaffolds (POC are discussed in the context of established grafting strategies. With POC scaffolds to cradle the growth of MSCs and hematopoietic progenitor cells, developing a fibroelastic network guided by cytokines and growth factors may contribute towards consistent graft constructs, enhanced functionality, and better patient outcomes.

  13. [The history of flexor tendon surgery].

    Science.gov (United States)

    Chamay, A

    1997-01-01

    Flexor tendon injuries were already treated in antiquity by Hippocrates, Galien and Avicenne. Since the Renaissance, other surgeons have attempted to repair flexor tendon injuries, but without success due to problems related to unsuitable materials and ignorance of the basic rules of asepsis and the absence of antiseptics until the second half of the 19th century. The first successful flexor tendon grafts in man were performed by K. Biesalski in 1910, E. Lexer in 1912 and L. Mayer in 1916. These three authors published their series of grafts and described in detail the anatomical, physiological and technical principles to be respected. St. Bunnell, in 1918, developed various pull-out direct suture procedures, but faced with the problems of adhesions, he abandoned this technique and proposed not to repair flexors in the digital tunnels but to graft them. He defined the famous zone which he called No man's land, which subsequently became Claude Verdan's zone II, in 1959. In 1960, C. Verdan published his first series of sutures maintained by 2 pins in zone II with comparable results to those obtained after grafting. In 1967, H. Kleinert, with his mobile suture, became the leader of direct tendon repair in zone II. 2-stage grafts were introduced in 1965 under the impetus of J. Hunter, who revised and popularized the studies conducted by A. Bassett and R.E. Caroll in 1950.

  14. Correlation between hindfoot joint three-dimensional kinematics and the changes of the medial arch angle in stage II posterior tibial tendon dysfunction flatfoot.

    Science.gov (United States)

    Zhang, Yi-Jun; Xu, Jian; Wang, Yue; Lin, Xiang-Jin; Ma, Xin

    2015-02-01

    The aim of this study was to explore the correlation between the kinematics of the hindfoot joint and the medial arch angle change in stage II posterior tibial tendon dysfunction flatfoot three-dimensionally under loading. Computed tomography (CT) scans of 12 healthy feet and 12 feet with stage II posterior tibial tendon dysfunction flatfoot were taken both in non- and full-body-weight-bearing condition. The CT images of the hindfoot bones were reconstructed into three-dimensional models with Mimics and Geomagic reverse engineering software. The three-dimensional changes of the hindfoot joint were calculated to determine their correlation to the medial longitudinal arch angle. The medial arch angle change was larger in stage II posterior tibial tendon dysfunction flatfoot compared to that in healthy foot under loading. The rotation and translation of the talocalcaneal joint, the talonavicular joint and the calcanocuboid joint had little influence on the change of the medial arch angle in healthy foot. However, the eversion of the talocalcaneal joint, the proximal translation of the calcaneus relative to the talus and the dorsiflexion of talonavicular joint could increase the medial arch angle in stage II posterior tibial tendon dysfunction flatfoot under loading. Joint instability occurred in patients with stage II posterior tibial tendon dysfunction flatfoot under loading. Limitation of over movement of the talocalcaneal joint and the talonavicular joint may help correct the medial longitudinal arch in stage II posterior tibial tendon dysfunction flatfoot. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Mineral distributions at the developing tendon enthesis.

    Science.gov (United States)

    Schwartz, Andrea G; Pasteris, Jill D; Genin, Guy M; Daulton, Tyrone L; Thomopoulos, Stavros

    2012-01-01

    Tendon attaches to bone across a functionally graded interface, "the enthesis". A gradient of mineral content is believed to play an important role for dissipation of stress concentrations at mature fibrocartilaginous interfaces. Surgical repair of injured tendon to bone often fails, suggesting that the enthesis does not regenerate in a healing setting. Understanding the development and the micro/nano-meter structure of this unique interface may provide novel insights for the improvement of repair strategies. This study monitored the development of transitional tissue at the murine supraspinatus tendon enthesis, which begins postnatally and is completed by postnatal day 28. The micrometer-scale distribution of mineral across the developing enthesis was studied by X-ray micro-computed tomography and Raman microprobe spectroscopy. Analyzed regions were identified and further studied by histomorphometry. The nanometer-scale distribution of mineral and collagen fibrils at the developing interface was studied using transmission electron microscopy (TEM). A zone (∼20 µm) exhibiting a gradient in mineral relative to collagen was detected at the leading edge of the hard-soft tissue interface as early as postnatal day 7. Nanocharacterization by TEM suggested that this mineral gradient arose from intrinsic surface roughness on the scale of tens of nanometers at the mineralized front. Microcomputed tomography measurements indicated increases in bone mineral density with time. Raman spectroscopy measurements revealed that the mineral-to-collagen ratio on the mineralized side of the interface was constant throughout postnatal development. An increase in the carbonate concentration of the apatite mineral phase over time suggested possible matrix remodeling during postnatal development. Comparison of Raman-based observations of localized mineral content with histomorphological features indicated that development of the graded mineralized interface is linked to endochondral

  16. Changes in Achilles tendon mechanical properties following eccentric heel drop exercise are specific to the free tendon.

    Science.gov (United States)

    Obst, S J; Newsham-West, R; Barrett, R S

    2016-04-01

    Mechanical loading of the Achilles tendon during isolated eccentric contractions could induce immediate and region-dependent changes in mechanical properties. Three-dimensional ultrasound was used to examine the immediate effect of isolated eccentric exercise on the mechanical properties of the distal (free tendon) and proximal (gastrocnemii) regions of the Achilles tendon. Participants (n = 14) underwent two testing sessions in which tendon measurements were made at rest and during a 30% and 70% isometric plantar flexion contractions immediately before and after either: (a) 3 × 15 eccentric heel drops or (b) 10-min rest. There was a significant time-by-session interaction for free tendon length and strain for all loading conditions (P tendon length and strain at all contraction intensities after eccentric exercise (P tendon for any of the measured parameters. Immediate changes in Achilles tendon mechanical properties were specific to the free tendon and consistent with changes due to mechanical creep. These findings suggest that the mechanical properties of the free tendon may be more vulnerable to change with exercise compared with the gastrocnemii aponeurosis or tendon. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. [Application of joint reconstruction with autogenous coronoid process graft to treat temporomandibular joint ankylosis].

    Science.gov (United States)

    Xie, Qing-tiao; Huang, Xuan-ping; Jiang, Xian-fang; Yang, Yuan-yuan; Li, Hua; Lin, Xi

    2013-08-01

    To evaluate the clinical effect of joint reconstruction by using autogenous coronoid process graft to treat temporomandibular joint(TMJ) ankylosis. Nine cases of TMJ ankylosis from September 2008 to September 2010 were surgically treated by joint reconstruction with autogenous coronoid process graft, using autogenous articular disc or prosthodontic membrane as interpositional material. Mouth opening, occlusion and cone beam CT(CBCT) were used for evaluation before and after surgery. Satisfactory mouth opening was achieved in all patients and no one got occlusal changes or reankylosis during follow-up. CBCT showed that coronoid process graft reached bone union with the ramus and turned to be round. It is effective to cure TMJ ankylosis through joint reconstruction with autogenous coronoid process graft.

  18. Development of hybrid polymer scaffolds for potential applications in ligament and tendon tissue engineering

    Energy Technology Data Exchange (ETDEWEB)

    Sahoo, Sambit [Tissue Repair Lab, Division of Bioengineering, National University of Singapore, Singapore 117574 (Singapore); Cho-Hong, James Goh [Tissue Repair Lab, Division of Bioengineering, National University of Singapore, Singapore 117574 (Singapore); Siew-Lok, Toh [Tissue Repair Lab, Division of Bioengineering, National University of Singapore, Singapore 117574 (Singapore)

    2007-09-15

    Fibre-based scaffolds have been widely used for tendon and ligament tissue engineering. Knitted scaffolds have been proved to favour collagenous matrix deposition which is crucial for tendon/ligament reconstruction. However, such scaffolds have the limitation of being dependent on a gel system for cell seeding, which is unstable in a dynamic environment such as the knee joint. This study developed three types of hybrid scaffolds, based on knitted biodegradable polyester scaffolds, aiming to improve mechanical properties and cell attachment and proliferation on the scaffolds. The hybrid scaffolds were created by coating the knitted scaffolds with a thin film of poly ({epsilon}-caprolactone) (group I), poly (D, L-lactide-co-glycolide) nanofibres (group II) and type 1 collagen (group III). Woven scaffolds were also fabricated and compared with the various hybrid scaffolds in terms of their mechanical properties during in vitro degradation and cell attachment and growth. This study demonstrated that the coating techniques could modulate the mechanical properties and facilitate cell attachment and proliferation in the hybrid scaffold, which could be applied with promise in tissue engineering of tendons/ligaments.

  19. Development of hybrid polymer scaffolds for potential applications in ligament and tendon tissue engineering

    International Nuclear Information System (INIS)

    Sahoo, Sambit; Cho-Hong, James Goh; Siew-Lok, Toh

    2007-01-01

    Fibre-based scaffolds have been widely used for tendon and ligament tissue engineering. Knitted scaffolds have been proved to favour collagenous matrix deposition which is crucial for tendon/ligament reconstruction. However, such scaffolds have the limitation of being dependent on a gel system for cell seeding, which is unstable in a dynamic environment such as the knee joint. This study developed three types of hybrid scaffolds, based on knitted biodegradable polyester scaffolds, aiming to improve mechanical properties and cell attachment and proliferation on the scaffolds. The hybrid scaffolds were created by coating the knitted scaffolds with a thin film of poly (ε-caprolactone) (group I), poly (D, L-lactide-co-glycolide) nanofibres (group II) and type 1 collagen (group III). Woven scaffolds were also fabricated and compared with the various hybrid scaffolds in terms of their mechanical properties during in vitro degradation and cell attachment and growth. This study demonstrated that the coating techniques could modulate the mechanical properties and facilitate cell attachment and proliferation in the hybrid scaffold, which could be applied with promise in tissue engineering of tendons/ligaments

  20. Estudo prospectivo randomizado sobre a luxação traumática de patela: tratamento conservador versus reconstrução do ligamento femoropatelar medial com tendão patelar - mínimo de dois anos de seguimento Randomized prospective study on traumatic patellar dislocation: conservative treatment versus reconstruction of the medial patellofemoral ligament using the patellar tendon, with a minimum of two years of follow-up

    Directory of Open Access Journals (Sweden)

    Alexandre Carneiro Bitar

    2011-01-01

    results were evaluated with a minimum follow-up of two years. The Kujala questionnaire was applied to assess pain and quality of life, and recurrences were evaluated. Pearson's chi-square test and Fisher's exact test were used in the statistical evaluation. RESULTS: The statistical analysis showed that the mean Kujala score was significantly lower in the conservative group (70.8, compared with the mean value in the surgical group (88.9, with p = 0.001. The surgical group presented a higher percentage of "good/excellent" Kujala score results (71.43% than in the conservative group (25.0%, with p = 0.003. The conservative group presented a greater number of recurrences (35% of the cases, while in the surgical group there were no reports of recurrences and/or subluxation. CONCLUSIONS: Treatment with reconstruction of the medial patellofemoral ligament using the patellar tendon produced better results, based on the analysis of post-treatment recurrences and the better final results from the Kujala questionnaire after a minimum follow-up period of two years.

  1. Effectiveness of xenogenous-based bovine-derived platelet gel embedded within a three-dimensional collagen implant on the healing and regeneration of the Achilles tendon defect in rabbits.

    Science.gov (United States)

    Moshiri, Ali; Oryan, Ahmad; Meimandi-Parizi, Abdolhamid; Koohi-Hosseinabadi, Omid

    2014-08-01

    Tissue engineering is an option in reconstructing large tendon defects and managing their healing and regeneration. We designed and produced a novel xenogeneic-based bovine platelet, embedded it within a tissue-engineered collagen implant (CI) and applied it in an experimentally induced large tendon defect model in rabbits to test whether bovine platelets could stimulate tendon healing and regeneration in vivo. One hundred twenty rabbits were randomly divided into two experimental and pilot groups. In all the animals, the left Achilles tendon was surgically excised and the tendon edges were aligned by Kessler suture. Each group was then divided into three groups of control (no implant), treated with CI and treated with collagen-platelet implant. The pilot groups were euthanized at 10, 15, 30 and 40 days post-injury (DPI), and their gross and histologic characteristics were evaluated to study host-graft interaction mechanism. To study the tendon healing and its outcome, the experimental animals were tested during the experiment using hematologic, ultrasonographic and various methods of clinical examinations and then euthanized at 60 DPI and their tendons were evaluated by gross pathologic, histopathologic, scanning electron microscopic, biophysical and biochemical methods. Bovine platelets embedded within a CI increased inflammation at short term while it increased the rate of implant absorption and matrix replacement compared with the controls and CI alone. Treatment also significantly increased diameter, density, amount, alignment and differentiation of the collagen fibrils and fibers and approximated the water uptake and delivery behavior of the healing tendons to normal contralaterals (p tendons and reduced peritendinous adhesion, muscle fibrosis and atrophy, and therefore, it improved the clinical scores and physical activity related to the injured limb when compared with the controls (p Achilles tendon in rabbit. This strategy may be a valuable option in the

  2. MR evaluation of the knee following anterior cruciate ligament reconstruction

    International Nuclear Information System (INIS)

    Rak, K.M.; Gillogly, S.D.; Schaefer, R.A.; Yakes, W.F.

    1991-01-01

    This paper evaluates the role of MR imaging of the knee after anterior cruciate ligament (ACL) reconstruction. Seventy-five MR examinations were performed in 52 patients following ACL reconstruction with patellar tendon autografts. MR imaging demonstrated a well-defined autograft in 63 of 70 clinically stable autografts. Of 5 clinically lax reconstructions, none appeared will defined on MR images. Compared with the clinical examination, MR imaging was 90.7% accurate. MR imaging demonstrated time-related healing of the patellar tendon donor site, with persistent thickening indicative of tendinitis. Positions of the femoral and tibial bone tunnels could be assessed. Knee joint effusions tended to resolve completely within 7 months after operations, with the presence and degree of effusion in the earlier postoperative interval being unrelated to the clinical outcome. Ancillary disorders in the knee, such as meniscal tears and osteochondral defects, could also be evaluated in this postoperative population

  3. A Tendon Cell Specific RNAi Screen Reveals Novel Candidates Essential for Muscle Tendon Interaction.

    Directory of Open Access Journals (Sweden)

    Prabhat Tiwari

    Full Text Available Tendons are fibrous connective tissue which connect muscles to the skeletal elements thus acting as passive transmitters of force during locomotion and provide appropriate body posture. Tendon-derived cues, albeit poorly understood, are necessary for proper muscle guidance and attachment during development. In the present study, we used dorsal longitudinal muscles of Drosophila and their tendon attachment sites to unravel the molecular nature of interactions between muscles and tendons. We performed a genetic screen using RNAi-mediated knockdown in tendon cells to find out molecular players involved in the formation and maintenance of myotendinous junction and found 21 candidates out of 2507 RNAi lines screened. Of these, 19 were novel molecules in context of myotendinous system. Integrin-βPS and Talin, picked as candidates in this screen, are known to play important role in the cell-cell interaction and myotendinous junction formation validating our screen. We have found candidates with enzymatic function, transcription activity, cell adhesion, protein folding and intracellular transport function. Tango1, an ER exit protein involved in collagen secretion was identified as a candidate molecule involved in the formation of myotendinous junction. Tango1 knockdown was found to affect development of muscle attachment sites and formation of myotendinous junction. Tango1 was also found to be involved in secretion of Viking (Collagen type IV and BM-40 from hemocytes and fat cells.

  4. Motor responses to experimental Achilles tendon pain

    DEFF Research Database (Denmark)

    Henriksen, Marius; Aaboe, Jens; Graven-Nielsen, Thomas

    2011-01-01

    of the exercise are affected by Achilles tendon pain. Objective The authors aimed to determine the effects of experimental Achilles tendon pain on motor function during one-legged weight bearing ankle plantar and dorsal flexion exercises. Methods In a crossover study, with 16 healthy subjects tested on two......Background Achilles tendinopathies are characterised by pain and reduced function, and heavy-load exercises have been shown to be effective in the treatment of painful chronic Achilles tendinopathies. However, basic information is needed on how the biomechanics and neuromuscular control...... different days separated by 1 week, three-dimensional ground reaction forces, ankle joint kinematics and surface electromyography (EMG) of the lower leg muscles were recorded during one-legged full weight-bearing ankle plantar (concentric) and dorsal (eccentric) flexion exercises. Measurements were done...

  5. A passive exoskeleton with artificial tendons: design and experimental evaluation.

    Science.gov (United States)

    van Dijk, Wietse; van der Kooij, Herman; Hekman, Edsko

    2011-01-01

    We developed a passive exoskeleton that was designed to minimize joint work during walking. The exoskeleton makes use of passive structures, called artificial tendons, acting in parallel with the leg. Artificial tendons are elastic elements that are able to store and redistribute energy over the human leg joints. The elastic characteristics of the tendons have been optimized to minimize the mechanical work of the human leg joints. In simulation the maximal reduction was 40 percent. The performance of the exoskeleton was evaluated in an experiment in which nine subjects participated. Energy expenditure and muscle activation were measured during three conditions: Normal walking, walking with the exoskeleton without artificial tendons, and walking with the exoskeleton with the artificial tendons. Normal walking was the most energy efficient. While walking with the exoskeleton, the artificial tendons only resulted in a negligibly small decrease in energy expenditure. © 2011 IEEE

  6. Imaging the infrapatellar tendon in the elite athlete

    International Nuclear Information System (INIS)

    Peace, K.A.L.; Lee, J.C.; Healy, J.

    2006-01-01

    Extensor mechanism injuries constitute a major cause of anterior knee pain in the elite athlete. Sonography and magnetic resonance imaging (MRI) are the imaging methods of choice when assessing the infrapatellar tendon. A comprehensive imaging review of infrapatellar tendon normal anatomy, tendinopathy, and partial/full-thickness tendon tears is provided. The value of imaging the infrapatellar tendon in clinical practice, including whether sonography can predict symptoms in asymptomatic athletes, is discussed. Acute avulsion fractures, including periosteal sleeve avulsion, and chronic avulsion injuries, including Sinding-Larsen-Johansson and Osgood-Schlatter syndromes, are shown. Mimics of infrapatellar tendon pathology, including infrapatellar plica injury, patellar tendon-lateral femoral condyle friction syndrome, and Hoffa's syndrome, are illustrated

  7. About tendon tissue regeneration in experimental radiation disease

    Energy Technology Data Exchange (ETDEWEB)

    Popov, D; Trichkova, P

    1976-01-01

    Under the conditions of experimental acute radiation disease the authors study the tendon tissue regeneration after suture of the lateral part of the gastrocnemius muscle tendon. Tendon auto and alloplasty were applied. In four postoperative periods the histological features are described in details as well as the characteristic phenomena observed during the regeneration influenced to a considerable degree by the irradiation. Round cell infiltration, large necrotic zones, erythrocyte infiltrations as well as predominance of non-specific tendon regeneration long after the surgery characterize the recovery period of the traumatically damaged tendon, nevertheless that at the end there is real tendon regeneration even though in a longer period in comparison with the controls (non-irradiated animals).

  8. Three-dimensional study of pectoralis major muscle and tendon architecture.

    Science.gov (United States)

    Fung, Lillia; Wong, Brian; Ravichandiran, Kajeandra; Agur, Anne; Rindlisbacher, Tim; Elmaraghy, Amr

    2009-05-01

    A thorough understanding of the normal structural anatomy of the pectoralis major (PM) is of paramount importance in the planning of PM tendon transfers or repairs following traumatic PM tears. However, there is little consensus regarding the complex musculotendinous architecture of the PM in the anatomic or surgical literature. The purpose of this study is to model and quantify the three-dimensional architecture of the pectoralis muscle and tendon. Eleven formalin embalmed cadaveric specimens were examined: five (2M/3F) were serially dissected, digitized, and modeled in 3D using Autodesk Maya; six (4M/2F) were dissected and photographed. The PM tendon consisted of longer anterior and shorter posterior layers that were continuous inferiorly. The muscle belly consisted of an architecturally uniform clavicular head (CH) and a segmented sternal head (SH) with 6-7 segments. The most inferior SH segment in all specimens was found to fold anteriorly forming a trough that cradled the inferior aspect of the adjacent superior segment. No twisting of either the PM muscle or tendon was noted. Within the CH, the fiber bundle lengths (FBL) were found to increase from superior to inferior, whereas the mean FBLs of SH were greatest in segments 3-5 found centrally. The mean lateral pennation angle was greater in the CH (29.4 +/- 6.9 degrees ) than in the SH (20.6 +/- 2.7 degrees ). The application of these findings could form the basis of future studies to optimize surgical planning and functional recovery of repair/reconstruction procedures.

  9. Calcaneal Tendon Collagen Fiber Morphometry and Aging

    Czech Academy of Sciences Publication Activity Database

    Hadraba, Daniel; Janáček, Jiří; Filová, Eva; Lopot, F.; Paesen, R.; Fanta, O.; Jarman, A.; Nečas, A.; Ameloot, M.; Jelen, K.

    2017-01-01

    Roč. 23, č. 5 (2017), s. 1040-1047 ISSN 1431-9276 R&D Projects: GA ČR(CZ) GA16-14758S; GA MŠk(CZ) LO1309; GA MŠk(CZ) LM2015062 Institutional support: RVO:67985823 ; RVO:68378041 Keywords : collagen * aging * crimp * fiber orientation * tendon Subject RIV: EB - Genetics ; Molecular Biology; BO - Biophysics (UEM-P) OBOR OECD: Developmental biology; Biophysics (UEM-P) Impact factor: 1.891, year: 2016

  10. Arthroscopically-Asissted Achilles Tendon Repair; Long-Term Results

    OpenAIRE

    Turgut, Ak?n; Asfuro?lu, Mert Zeynel

    2014-01-01

    Objectives: The ruptures of the Achilles tendon (AT) are relatively common. Since there is no consensus on the best method of the repair of the AT; the treatment is determined on the preference of the surgeon and the patient. The study evaluating the cadaveric and short term clinical results done by our clinic in 2002, has shown us that arthroscopically Achilles tendon repair can be good choise in achilles tendon ruptures. Methods: Fortyfour patients who underwent arthroscopically assisted ac...

  11. Contrast material filling of the peroneal tendon sheath

    International Nuclear Information System (INIS)

    Zadravecz, Gy.; Grexa, E.

    1981-01-01

    In case of complaints after fracture of the calcaneus the common sheath of the peroneus tendons was filled up with contrast material. The tendon sheath was punctured Oehind the external ankle. The three-directional radiograms clearly showed the dislocation and compression of the tendons, caused by the exostosis of the calcaneus. The concomitant tendovaginitis caused the complaints. This alteration was observed in 11% of all the calcaneus fractures. (L.E.)

  12. 77 FR 69508 - Inservice Inspection of Prestressed Concrete Containment Structures With Grouted Tendons

    Science.gov (United States)

    2012-11-19

    ... Containment Structures With Grouted Tendons AGENCY: Nuclear Regulatory Commission. ACTION: Regulatory guide... (RG) 1.90, ``Inservice Inspection of Prestressed Concrete Containment Structures with Grouted Tendons... appropriate surveillance program for prestressed concrete containment structures with grouted tendons...

  13. Nanoparticles for tendon healing and regeneration: literature review.

    Directory of Open Access Journals (Sweden)

    Paolo Domenico Parchi

    2016-08-01

    Full Text Available Tendon injuries are commonly met in the emergency department. Unfortunately, tendon tissue has limited regeneration potential and usually the consequent formation of scar tissue causes inferior mechanical properties Nanoparticles could be used in different way to improve tendon healing and regeneration, ranging from scaffolds manufacturing (increasing the strength and endurance or anti-adhesions, anti-microbial and anti-inflammatory properties to gene therapy. This paper aims to summarize the most relevant studies showing the potential application of nanoparticles for tendon tissue regeneration

  14. Tendon synovial cells secrete fibronectin in vivo and in vitro

    International Nuclear Information System (INIS)

    Banes, A.J.; Link, G.W.; Bevin, A.G.; Peterson, H.D.; Gillespie, Y.; Bynum, D.; Watts, S.; Dahners, L.

    1988-01-01

    The chemistry and cell biology of the tendon have been largely overlooked due to the emphasis on collagen, the principle structural component of the tendon. The tendon must not only transmit the force of muscle contraction to bone to effect movement, but it must also glide simultaneously over extratendonous tissues. Fibronectin is classified as a cell attachment molecule that induces cell spreading and adhesion to substratum. The external surface of intact avian flexor tendon stained positively with antibody to cellular fibronectin. However, if the surface synovial cells were first removed with collagenase, no positive reaction with antifibronectin antibody was detected. Analysis of immunologically stained frozen sections of tendon also revealed fibronectin at the tendon synovium, but little was associated with cells internal in tendon. The staining pattern with isolated, cultured synovial cells and fibroblasts from the tendon interior substantiated the histological observations. Analysis of polyacrylamide gel profiles of 35 S-methionine-labeled proteins synthesized by synovial cells and internal fibroblasts indicated that fibronectin was synthesized principally by synovial cells. Fibronectin at the tendon surface may play a role in cell attachment to prevent cell removal by the friction of gliding. Alternatively, fibronectin, with its binding sites for hyaluronic acid and collagen, may act as a complex for boundary lubrication

  15. Magnetic resonance imaging and computed radiography in Achilles tendon rupture

    International Nuclear Information System (INIS)

    Korenaga, Tateo; Hachiya, Junichi; Miyasaka, Yasuo

    1988-01-01

    Magnetic Resonance Imaging (MRI) and Computed Radiography (CR) were performed in 15 patients with complete Achilles tendon rupture who were treated conservatively without surgery. MRI was obtained using Toshiba MRT 50 A superconductive machine, operaing at 0.5 Tesla. CR was performed by CR-101, Fuji Medical System. In fresh cases, ruptured tendons showed intermediate signal intensity on T1-weighted images and high intensity on T2-weighted images. Thickening of the tendon was observed in all cases except in very acute stage. Configuration of thickend tendons tends to be dumbbell shape in subacute stage and fusiform in chronic stage of more than six months after the initial trauma. In cases which showed high signal intensity at the ruptured area both on T1 and T2 weighted images, migration of fat into the sapces between the ruptured tendons was considered to be the major source of increased signal intensity. Computed radiography showed thickening of the tendon, blurring of anterior margin of the tendon, and decreased translucency of pre-Achilles fat pad. However, MRI better demonstrated the details of ruptured tendons when compared to CR, and thought to be an usefull way of following up the healing process of the ruptured tendon to facilitate more reasonable judgement of the time of removing plaster casts and stating exercise. (author)

  16. Ossification of the bilateral Achilles tendon: a rare entity

    International Nuclear Information System (INIS)

    Arora, Abhishek J; Arora, Richa

    2015-01-01

    Ossification of the Achilles tendon is a rare clinical entity comprising of one or more segments of variable sized ossified masses in the fibrocartilaginous substance of the tendon. The etiology of ossification of the Achilles tendon is multifactorial with recurrent trauma and surgery comprising major predisposing factors, with others being metabolic, systemic, and infectious diseases. The possibility of a genetic predisposition towards this entity has also been raised, but has not yet been proven. We present a rare case of ossification of the bilateral Achilles tendons without any history of trauma or surgery in a 48-year-old female patient

  17. Numerical models for prestressing tendons in containment structures

    International Nuclear Information System (INIS)

    Kwak, Hyo-Gyoung; Kim, Jae Hong

    2006-01-01

    Two modified stress-strain relations for bonded and unbonded internal tendons are proposed. The proposed relations can simulate the post-cracking behavior and tension stiffening effect in prestressed concrete containment structures. In the case of the bonded tendon, tensile forces between adjacent cracks are transmitted from a bonded tendon to concrete by bond forces. Therefore, the constitutive law of a bonded tendon stiffened by grout needs to be determined from the bond-slip relationship. On the other hand, a stress increase beyond the effective prestress in an unbonded tendon is not section-dependent but member-dependent. It means that the tendon stress unequivocally represents a uniform distribution along the length when the friction loss is excluded. Thus, using a strain reduction factor, the modified stress-strain curve of an unbonded tendon is derived by successive iterations. In advance, the prediction of cracking behavior and ultimate resisting capacity of prestressed concrete containment structures using the introduced numerical models are succeeded, and the need for the consideration of many influencing factors such as the tension stiffening effect, plastic hinge length and modification of stress-strain relation of tendon is emphasized. Finally, the developed numerical models are applied to prestressed concrete containment structures to verify the efficiency and applicability in simulating the structural behavior with bonded and/or unbonded tendons

  18. Experimental and Numerical Analysis of Screw Fixation in Anterior Cruciate Ligament Reconstruction

    Science.gov (United States)

    Chizari, Mahmoud; Wang, Bin; Snow, Martyn; Barrett, Mel

    2008-09-01

    This paper reports the results of an experimental and finite element analysis of tibial screw fixation in anterior cruciate ligament (ACL) reconstruction. The mechanical properties of the bone and tendon graft are obtained from experiments using porcine bone and bovine tendon. The results of the numerical study are compared with those from mechanical testing. Analysis shows that the model may be used to establish the optimum placement of the tunnel in anterior cruciate ligament reconstruction by predicting mechanical parameters such as stress, strain and displacement at regions in the tunnel wall.

  19. Increased supraspinatus tendon thickness following fatigue loading in rotator cuff tendinopathy: potential implications for exercise therapy

    OpenAIRE

    McCreesh, Karen M; Purtill, Helen; Donnelly, Alan E; Lewis, Jeremy S

    2017-01-01

    Background/aim Exercise imparts a load on tendon tissue that leads to changes in tendon properties. Studies suggest that loading immediately reduces tendon thickness, with a loss of this response in symptomatic tendinopathy. No studies investigating the response of tendon dimensions to load for the rotator cuff tendons exist. This study aimed to examine the short-term effect of loading on the thickness of the supraspinatus tendon and acromiohumeral distance those with and without rotator cuff...

  20. Repair of Achilles tendon defect with autologous ASCs engineered tendon in a rabbit model.

    Science.gov (United States)

    Deng, Dan; Wang, Wenbo; Wang, Bin; Zhang, Peihua; Zhou, Guangdong; Zhang, Wen Jie; Cao, Yilin; Liu, Wei

    2014-10-01

    Adipose derived stem cells (ASCs) are an important cell source for tissue regeneration and have been demonstrated the potential of tenogenic differentiation in vitro. This study explored the feasibility of using ASCs for engineered tendon repair in vivo in a rabbit Achilles tendon model. Total 30 rabbits were involved in this study. A composite tendon scaffold composed of an inner part of polyglycolic acid (PGA) unwoven fibers and an outer part of a net knitted with PGA/PLA (polylactic acid) fibers was used to provide mechanical strength. Autologous ASCs were harvested from nuchal subcutaneous adipose tissues and in vitro expanded. The expanded ASCs were harvested and resuspended in culture medium and evenly seeded onto the scaffold in the experimental group, whereas cell-free scaffolds served as the control group. The constructs of both groups were cultured inside a bioreactor under dynamic stretch for 5 weeks. In each of 30 rabbits, a 2 cm defect was created on right side of Achilles tendon followed by the transplantation of a 3 cm cell-seeded scaffold in the experimental group of 15 rabbits, or by the transplantation of a 3 cm cell-free scaffold in the control group of 15 rabbits. Animals were sacrificed at 12, 21 and 45 weeks post-surgery for gross view, histology, and mechanical analysis. The results showed that short term in vitro culture enabled ASCs to produce matrix on the PGA fibers and the constructs showed tensile strength around 50 MPa in both groups (p > 0.05). With the increase of implantation time, cell-seeded constructs gradually form neo-tendon and became more mature at 45 weeks with histological structure similar to that of native tendon and with the presence of bipolar pattern and D-periodic structure of formed collagen fibrils. Additionally, both collagen fibril diameters and tensile strength increased continuously with significant difference among different time points (p tendon tissue with fibril structure observable only at 45 weeks

  1. Role of tissue-engineered artificial tendon in healing of a large Achilles tendon defect model in rabbits.

    Science.gov (United States)

    Moshiri, Ali; Oryan, Ahmad; Meimandi-Parizi, Abdolhamid

    2013-09-01

    Treatment of large Achilles tendon defects is technically demanding. Tissue engineering is an option. We constructed a collagen-based artificial tendon, covered it with a polydioxanon (PDS) sheath, and studied the role of this bioimplant on experimental tendon healing in vivo. A 2-cm tendon gap was created in the left Achilles tendon of rabbits (n = 120). The animals were randomly divided into 3 groups: control (no implant), treated with tridimensional-collagen, and treated with tridimensional-collagen-bidimensional-PDS implants. Each group was divided into 2 subgroups of 60 and 120 days postinjury (DPI). Another 50 pilot animals were used to study the host-implant interaction. Physical activity of the animals was scored and ultrasonographic and bioelectrical characteristics of the injured tendons were investigated weekly. After euthanasia, macro, micro, and nano morphologies and biophysical and biomechanical characteristics of the healing tendons were studied. Treatment improved function of the animals, time dependently. At 60 and 120 DPI, the treated tendons showed significantly higher maximum load, yield, stiffness, stress, and modulus of elasticity compared with controls. The collagen implant induced inflammation and absorbed the migrating fibroblasts in the defect area. By its unique architecture, it aligned the fibroblasts and guided their proliferation and collagen deposition along the stress line of the tendon and resulted in improved collagen density, micro-amp, micro-ohm, water uptake, and delivery of the regenerated tissue. The PDS-sheath covering amplified these characteristics. The implants were gradually absorbed and replaced by a new tendon. Minimum amounts of peritendinous adhesion, muscle atrophy, and fibrosis were observed in the treated groups. Some remnants of the implants were preserved and accepted as a part of the new tendon. The implants were cytocompatible, biocompatible, biodegradable, and effective in tendon healing and regeneration. This

  2. The Effect of Phospholipids (Surfactant on Adhesion and Biomechanical Properties of Tendon: A Rat Achilles Tendon Repair Model

    Directory of Open Access Journals (Sweden)

    T. Kursat Dabak

    2015-01-01

    Full Text Available Adhesion of the tendon is a major challenge for the orthopedic surgeon during tendon repair. Manipulation of biological environment is one of the concepts to prevent adhesion. Lots of biochemicals have been studied for this purpose. We aimed to determine the effect of phospholipids on adhesion and biomechanical properties of tendon in an animal tendon repair model. Seventy-two Wistar rats were divided into 4 groups. Achilles tendons of rats were cut and repaired. Phospholipids were applied at two different dosages. Tendon adhesion was determined histopathologically and biomechanical test was performed. At macroscopic evaluation of adhesion, there are statistically significant differences between multiple-dose phospholipid injection group and Control group and also hyaluronic acid group and Control group (p0.008. Ultimate strength was highest at hyaluronic acid injection group and lowest at multiple-dose phospholipid injection group. Single-dose phospholipids (surfactant application may have a beneficial effect on the tendon adhesion. Although multiple applications of phospholipids seem the most effective regime to reduce the tendon adhesion among groups, it deteriorated the biomechanical properties of tendon.

  3. Science to Practice: Quantitative US Elastography Can Be Used to Quantify Mechanical and Histologic Tendon Healing in a Rabbit Model of Achilles Tendon Transection.

    Science.gov (United States)

    Lee, Kenneth S; Martin, Jack; Thelen, Darryl

    2017-05-01

    Compression-based ultrasonographic (US) elastography is associated with time-dependent mechanical and histologic changes of the healing tendon in a transected rabbit model of the Achilles tendon. This finding will lead to continued development of quantitative US, which can be used to objectively assess a diseased or healing tendon. With advances in the method used, clinical translation of tendon elastography may enable clinicians to diagnose tendon damage and track healing, which should improve both treatment and outcome.

  4. MRI of anterior cruciate ligament repair with patellar and hamstring tendon autografts

    International Nuclear Information System (INIS)

    Jansson, K.A.; Karjalainen, P.T.; Harilainen, A.; Sandelin, J.; Tallroth, K.; Soila, K.; Aronen, H.J.

    2001-01-01

    Objective. Several MRI sequences were used to evaluate the 2-year postoperative appearance of asymptomatic knee with a torn anterior cruciate ligament (ACL) reconstructed with bone-patellar tendon-bone (BTB) and semitendinosus and gracilis (STG) tendon autografts.Design and patients. Two groups with successful repair of ACL tear with BTB (n=10) or STG (n=10) autografts were imaged at 1.5 T with sagittal and oblique coronal proton density-, T2-weighted and sagittal STIR sequences and plain and contrast-enhanced oblique coronal T1-weighted sequences. The appearance of the graft and periligamentous tissues was evaluated.Results. In all 20 cases, the ACL graft showed homogeneous, low signal intensity with periligamentous streaks of intermediate signal intensity on T2-weighted images. In 10 cases, localised areas of intermediate signal intensity were seen in the intra-articular segment of the graft on proton density- and T1-weighted images. The graft itself did not show enhancement in either of the two groups, but mild to moderate periligamentous enhancement was detected in 10 cases.Conclusion. The MRI appearance of ACL autograft is variable on proton density- and T1-weighted images. Periligamentous tissue showing contrast enhancement is a typical MRI finding after clinically successful ACL reconstruction. (orig.)

  5. Measurement of stress strain and vibrational properties of tendons

    Science.gov (United States)

    Revel, Gian Marco; Scalise, Alessandro; Scalise, Lorenzo

    2003-08-01

    The authors present a new non-intrusive experimental procedure based on laser techniques for the measurement of mechanical properties of tendons. The procedure is based on the measurement of the first resonance frequency of the tendon by laser Doppler vibrometry during in vitro tensile experiments, with the final aim of establishing a measurement procedure to perform the mechanical characterization of tendons by extracting parameters such as the resonance frequency, also achievable during in vivo investigation. The experimental procedure is reported, taking into account the need to simulate the physiological conditions of the Achilles tendon, and the measurement technique used for the non-invasive determination of tendon cross-sectional area during tensile vibration tests at different load levels is described. The test procedure is based on a tensile machine, which measures longitudinal tendons undergoing controlled load conditions. Cross-sectional area is measured using a new non-contact procedure for the measurement of tendon perimeter (repeatability of 99% and accuracy of 2%). For each loading condition, vibration resonance frequency and damping, cross-sectional area and tensile force are measured, allowing thus a mechanical characterization of the tendon. Tendon stress-strain curves are reported. Stress-strain curves have been correlated to the first vibration resonance frequency and damping of the tendon measured using a single-point laser Doppler vibrometer. Moreover, experimental results have been compared with a theoretical model of a vibrating cord showing discrepancies. In vitro tests are reported, demonstrating the validity of the method for the comparison of different aged rabbit tendons.

  6. The Relation between Calcium Supplement Consumption and Calcific Shoulder Tendonitis

    Directory of Open Access Journals (Sweden)

    Alireza Rouhani

    2015-10-01

    Full Text Available Background: Calcific tendonitis is a common cause of non-traumatic shoulder pain. Previous studies have suggested a relation between minerals and endocrine and calcium deposition. Thus, hypercalcemia is probably related to calcific tendonitis. This study aims at evaluating the relation found between calcium supplement consumption and calcific shoulder tendonitis. Methods: This analytical-descriptive study was conducted on 250 patients with shoulder pain referring to clinics and emergency department of Shohada Orthopedics Hospital during one year for considering calcific shoulder tendonitis and calcium supplement consumption. Patients with calcific tendonitis were treated and their functional ability was evaluated using DASH questionnaire, pain severity and range of motion (ROM before and after treatment and their correlation with calcium supplement consumption. Results: Calcific tendonitis and calcium consumption were generally seen in 30 (12% and 73 (29.2% cases, respectively. Calcium consumption frequency in patients with calcific tendonitis was significantly higher than the patients who did not consume calcium supplements (76.7% vs. 22.7%. Patients with calcific tendonitis who did not consume calcium supplements suffered from significantly longer periods of shoulder pain. All patients having consumed calcium supplement were female. The group who consumed calcium supplement had significantly severe pain and higher DASH score before and after treatment, while there was no significant difference in number of impaired ROM before and after treatment. Also, there was a negative correlation between calcium supplement consumption, pain severity and DASH score before and after treatment. Conclusion: Calcium supplement consumption is related to calcific tendonitis and is also accompanied with more pain and lower functional ability in patients with calcific tendonitis.    Keywords: Calcific tendonitis; Shoulder; Calcium supplement; Pain

  7. Clinical evaluation of bone- patellar tendon- bone grafts for anterior cruciate ligament injury

    International Nuclear Information System (INIS)

    Nakamura, Yasuhiro

    2011-01-01

    One thousand and thirty-eight cases of Anterior Cruciate Ligament (ACL) rupture were treated between January 2002 and November 2010. Eight hundred sixty-six cases (83.9%) were observed for at least six months. All cases were reconstructed with a bone to tendon to bone (BTB) graft from the patella. Much effort was made to return the patient to a competitive sports activity level within one year. The age at suffering from the initial injury ranged from 9 to 74 years old with a mean of 24.7 years old. There were 493 female (50.7%) and 427 male (49.3%) cases. The injured side was right in 408 cases and left in 458 cases. The mean postoperative observation period was 449.2 days. The number of patients who felt 80% or more certain that they could return to competitive sports activities was 538 (61.9%). From the MRI findings, continuity of the reconstructed graft was observed in 793 cases (98.5%). Arthroscopy after reconstruction was performed in 775 cases (89.5%). The reconstructed ACL was observed to be covered with an adequate synovium in 629 cases (81.2%). The medial meniscus and lateral meniscus showed no changes in 657 cases (84.8%) and 666 cases (85.9%) respectively. Reconstructions performed less than two weeks after injury showed no significant differences in terms of Range Of Motion (ROM), arthroscopic findings, or the number of patients who could return to competitive sports activities. Statistically significantly more patients who underwent their reconstruction at an age over forty experienced a loss motion of five degree in extension or ten degree in flexion and resumed a lower level of sports activities. Patients who underwent the reconstruction could return to exercises for muscle strengthening and ROMs within 2 weeks. Patients over forty years old who underwent their reconstruction could prevent their menisci from fraying, tearing, or undergoing osteoarthritic changes. (author)

  8. One-stage treatment of delayed 'jersey finger' by Z-step lengthening of the flexor digitorum profundus tendon at the wrist.

    Science.gov (United States)

    Sawaya, Elias T; Choughri, Hussein; Pelissier, Philippe

    2012-02-01

    The authors report the case of a 19-year-old female with delayed presentation of a type II 'jersey finger' of the fourth dominant digit. A surgical approach was performed, revealing a retracted flexor digitorum profundus tendon within a still patent sheath. The resulting loss of tendon length overruled any possibility of direct reinsertion of the tendon. A lengthening "Z-step" tendinoplasty was then performed on the tendon at the wrist, thus enabling reinsertion at the base of the distal phalanx. The patient then underwent conventional splinting and physiotherapy. Total Active Motion was measured at 220° with a 6-month follow-up. Even though there is no clear consensus concerning management of such cases, different techniques have been described, such as one- or two-stage grafting, or tenotomy at the musculotendinous junction. Lengthening tendinoplasties have been applied by certain authors but only to the flexor pollicis longus tendon. To our knowledge, this is the only reported case of lengthening Z-step applied to a long digit for the repair of type II 'jersey finger' lesions. The satisfactory functional and cosmetic outcome encourages us to consider this one-stage technique in other select cases, in order to gather more formal evidence. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Mechanical Coupling between Muscle-Tendon Units Reduces Peak Stresses

    NARCIS (Netherlands)

    Maas, Huub; Finni, Taija

    2018-01-01

    The presence of mechanical linkages between synergistic muscles and their common tendons may distribute forces among the involved structures. We review studies, using humans and other animals, examining muscle and tendon interactions and discuss the hypothesis that connections between muscle bellies

  10. Tendinography for diagnosing injuries to tendons and ligaments

    International Nuclear Information System (INIS)

    Grevsten, S.; Eriksson, K.

    1979-01-01

    A radiographic method of tendinography is described. In rabbits no inflammatory reaction in the Achilles tendon was observed 12 to 15 days after injection of contrast medium. Effects of examination of two healthy subjects and a patient with a traumatic condition are described. Suitable amounts and concentrations of contrast medium for examinations of Achilies tendon and cruciate ligaments are discussed. (Auth.)

  11. Rehabilitation of tendon problems in patients with diabetes mellitus

    NARCIS (Netherlands)

    Rees, Jonathan; Gaida, Jamie E.; Silbernagel, Karin Grävare; Zwerver, Johannes; Anthony, Joseph S.; Scott, Alex; Ackermann, PW; Hart, DA

    2016-01-01

    Exercise is crucial in the management of diabetes mellitus and its associated complications. However, individuals with diabetes have a heightened risk of musculoskeletal problems, including tendon pathologies. Diabetes has a significant impact on the function of tendons due to the accumulation of

  12. Open extensor tendon injuries: an epidemiologic study.

    Science.gov (United States)

    Patillo, Dominic; Rayan, Ghazi M

    2012-01-01

    To report the epidemiology, mechanism, anatomical location, distribution, and severity of open extensor tendon injuries in the digits, hand, and forearm as well as the frequency of associated injuries to surrounding bone and soft tissue. Retrospective chart review was conducted for patients who had operative repair of open digital extensor tendon injuries in all zones within an 11-year period. Data was grouped according to patient characteristics, zone of injury, mechanism of injury, and presence of associated injury. Statistical analysis was used to determine the presence of relevant associations. Eighty-six patients with 125 severed tendons and 105 injured digits were available for chart reviews. Patients were predominantly males (83%) with a mean age of 34.2 years and the dominant extremity was most often injured (60%). The thumb was the most commonly injured (25.7%), followed by middle finger (24.8), whereas small finger was least affected (10.5%). Sharp laceration was the most common mechanism of injury (60%), and most of these occurred at or proximal to the metacarpophalangeal joints. Most saw injuries occurred distal to the metacarpophalangeal joint. Zone V was the most commonly affected in the fingers (27%) while zone VT was the most commonly affected in the thumb (69%). Associated injuries to bone and soft tissue occurred in 46.7% of all injuries with saw and crush/avulsions being predictive of fractures and damage to the underlying joint capsule. The extensor mechanism is anatomically complex, and open injuries to the dorsum of the hand, wrist, and forearm, especially of crushing nature and those inflicted by saws, must be thoroughly evaluated. Associated injuries should be ruled out in order to customize surgical treatment and optimize outcome.

  13. An Artificial Tendon with Durable Muscle Interface

    OpenAIRE

    Melvin, Alan; Litsky, Alan; Mayerson, Joel; Witte, David; Melvin, David; Juncosa-Melvin, Natalia

    2010-01-01

    A coupling mechanism that can permanently fix a forcefully contracting muscle to a bone anchor or any totally inert prosthesis would meet a serious need in orthopaedics. Our group developed the OrthoCoupler™ device to satisfy these demands. The objective of this study was to test OrthoCoupler’s performance in vitro and in vivo in the goat semitendinosus tendon model. For in vitro evaluation, 40 samples were fatigue-tested, cycling at 10 load levels, n=4 each. For in vivo evaluation, the semit...

  14. Torque Control of Underactuated Tendon-driven Robotic Fingers

    Science.gov (United States)

    Abdallah, Muhammad E. (Inventor); Ihrke, Chris A. (Inventor); Reiland, Matthew J. (Inventor); Wampler, Charles W. (Inventor); Diftler, Myron A. (Inventor); Platt, Robert (Inventor); Bridgwater, Lyndon (Inventor)

    2013-01-01

    A robotic system includes a robot having a total number of degrees of freedom (DOF) equal to at least n, an underactuated tendon-driven finger driven by n tendons and n DOF, the finger having at least two joints, being characterized by an asymmetrical joint radius in one embodiment. A controller is in communication with the robot, and controls actuation of the tendon-driven finger using force control. Operating the finger with force control on the tendons, rather than position control, eliminates the unconstrained slack-space that would have otherwise existed. The controller may utilize the asymmetrical joint radii to independently command joint torques. A method of controlling the finger includes commanding either independent or parameterized joint torques to the controller to actuate the fingers via force control on the tendons.

  15. Final report on PCRV thermal cylinder axial tendon failures

    International Nuclear Information System (INIS)

    Canonico, D.A.; Griess, J.C.; Robinson, G.C.

    1976-01-01

    The post-test examination of the failed tendons from the PCRV thermal cylinder experiment has been concluded. Failures in the wires are attributed to stress-corrosion cracking. The cause of tendon failures has not been unequivocably established, but they may have been due to nitrates in the duct. The wires employed in the manufacture of the tendons will crack in less than 72 hr in a 0.2 M solution of ammonium nitrate at 70 0 C. The quality of the wires is poor, and surface cracks were detected. These could have acted as concentrating sites for both stress and the deleterious contaminants. It is believed that the factors that led to the failures in the thermal cylinder experiment were unique. An improper formulation of the epoxy resin did not provide the tendon anchor plate seal that was desired; indeed, the improper formulation is responsible for the high level of nitrogen in the ducts of the failed tendons

  16. Nonoperative, dynamic treatment of acute achilles tendon rupture

    DEFF Research Database (Denmark)

    Barfod, Kristoffer Weisskirchner; Bencke, Jesper; Lauridsen, Hanne Bloch

    2015-01-01

    Acute Achilles tendon rupture alters the biomechanical properties of the plantar flexor muscle-tendon complex that can affect functional performance and the risk of repeat injury. The purpose of the present study was to compare the biomechanical properties of the plantar flexor muscle-tendon comp......Acute Achilles tendon rupture alters the biomechanical properties of the plantar flexor muscle-tendon complex that can affect functional performance and the risk of repeat injury. The purpose of the present study was to compare the biomechanical properties of the plantar flexor muscle...... in the terminal part of dorsiflexion was found in the non-weightbearing group. The altered stiffness and strength in the affected limb could affect the coordination of gait and running....

  17. Repair of full-thickness tendon injury using connective tissue progenitors efficiently derived from human embryonic stem cells and fetal tissues.

    Science.gov (United States)

    Cohen, Shahar; Leshansky, Lucy; Zussman, Eyal; Burman, Michael; Srouji, Samer; Livne, Erella; Abramov, Natalie; Itskovitz-Eldor, Joseph

    2010-10-01

    The use of stem cells for tissue engineering (TE) encourages scientists to design new platforms in the field of regenerative and reconstructive medicine. Human embryonic stem cells (hESC) have been proposed to be an important cell source for cell-based TE applications as well as an exciting tool for investigating the fundamentals of human development. Here, we describe the efficient derivation of connective tissue progenitors (CTPs) from hESC lines and fetal tissues. The CTPs were significantly expanded and induced to generate tendon tissues in vitro, with ultrastructural characteristics and biomechanical properties typical of mature tendons. We describe a simple method for engineering tendon grafts that can successfully repair injured Achilles tendons and restore the ankle joint extension movement in mice. We also show the CTP's ability to differentiate into bone, cartilage, and fat both in vitro and in vivo. This study offers evidence for the possibility of using stem cell-derived engineered grafts to replace missing tissues, and sets a basic platform for future cell-based TE applications in the fields of orthopedics and reconstructive surgery.

  18. Different Achilles Tendon Pathologies Show Distinct Histological and Molecular Characteristics

    Directory of Open Access Journals (Sweden)

    Franka Klatte-Schulz

    2018-01-01

    Full Text Available Reasons for the development of chronic tendon pathologies are still under debate and more basic knowledge is needed about the different diseases. The aim of the present study was therefore to characterize different acute and chronic Achilles tendon disorders. Achilles tendon samples from patients with chronic tendinopathy (n = 7, chronic ruptures (n = 6, acute ruptures (n = 13, and intact tendons (n = 4 were analyzed. The histological score investigating pathological changes was significantly increased in tendinopathy and chronic ruptures compared to acute ruptures. Inflammatory infiltration was detected by immunohistochemistry in all tendon pathology groups, but was significantly lower in tendinopathy compared to chronic ruptures. Quantitative real-time PCR (qRT-PCR analysis revealed significantly altered expression of genes related to collagens and matrix modeling/remodeling (matrix metalloproteinases, tissue inhibitors of metalloproteinases in tendinopathy and chronic ruptures compared to intact tendons and/or acute ruptures. In all three tendon pathology groups markers of inflammation (interleukin (IL 1β, tumor necrosis factor α, IL6, IL10, IL33, soluble ST2, transforming growth factor β1, cyclooxygenase 2, inflammatory cells (cluster of differentaition (CD 3, CD68, CD80, CD206, fat metabolism (fatty acid binding protein 4, peroxisome proliferator-activated receptor γ, CCAAT/enhancer-binding protein α, adiponectin, and innervation (protein gene product 9.5, growth associated protein 43, macrophage migration inhibitory factor were detectable, but only in acute ruptures significantly regulated compared to intact tendons. The study gives an insight into structural and molecular changes of pathological processes in tendons and might be used to identify targets for future therapy of tendon pathologies.

  19. Rotator cuff tendon connections with the rotator cable.

    Science.gov (United States)

    Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo

    2017-07-01

    The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.

  20. MRI and gross anatomy of the iliopsoas tendon complex

    International Nuclear Information System (INIS)

    Polster, Joshua M.; Lee, Ho; Klika, Alison; Barsoum, Wael; Drake, Richard; Elgabaly, Mohamed

    2008-01-01

    The objective was to explain the anatomic basis of a longitudinal cleft of increased signal in the iliopsoas tendon seen on hip MR arthrograms. A prospective review of 20 MR hip arthrograms was performed using standard and fat-suppressed T1-weighted images to establish whether or not the cleft was composed of fatty tissue and to define the anatomy of the iliopsoas tendon complex. Three cadaver dissections of the hip region were then performed for anatomic correlation. Fourteen out of 20 MR hip arthrograms demonstrated a longitudinal cleft of increased T1 signal adjacent to the iliopsoas tendon, which suppressed on frequency selective fat-suppressed images, indicating fatty composition. Gross anatomic correlation demonstrated this fatty cleft to represent a fascial plane adjacent to the iliopsoas tendon, in one case separating the iliopsoas tendon medially from a thin intramuscular tendon within the lateral portion of the iliacus muscle. Also noted was a direct muscular insertion of the lateral portion of the iliacus muscle onto the anterior portion of the proximal femoral diaphysis in all 3 cadavers. The anatomy of the iliopsoas tendon complex is more complicated than typically illustrated and includes the iliopsoas tendon itself attaching to the lesser trochanter, the lateral portion of the iliacus muscle attaching directly upon the anterior portion of the proximal femoral diaphysis, and a thin intramuscular tendon within this lateral iliacus muscle that is separated from the iliopsoas tendon by a cleft of fatty fascia that accounts for the MRI findings of a cleft of increased T1 signal. (orig.)

  1. Tendon injury and repair - A perspective on the basic mechanisms of tendon disease and future clinical therapy

    NARCIS (Netherlands)

    Snedeker, J.G.; Foolen, J.

    2017-01-01

    Tendon is an intricately organized connective tissue that efficiently transfers muscle force to the bony skeleton. Its structure, function, and physiology reflect the extreme, repetitive mechanical stresses that tendon tissues bear. These mechanical demands also lie beneath high clinical rates of

  2. Quadriceps Tendon Rupture and Contralateral Patella Tendon Avulsion Post Primary Bilateral Total Knee Arthroplasty: A Case Report

    Directory of Open Access Journals (Sweden)

    Gaurav Sharma

    2016-07-01

    Full Text Available Background: Extensor mechanism failure secondary to knee replacement could be due to tibial tubercle avulsion, Patellar tendon rupture, patellar fracture or quadriceps tendon rupture. An incidence of Patella tendon rupture of 0.17% and Quadriceps tendon rupture of around 0.1% has been reported after Total knee arthroplasty. These are considered a devastating complication that substantially affects the clinical results and are challenging situations to treat with surgery being the mainstay of the treatment. Case Description: We report here an interesting case of a patellar tendon rupture of one knee and Quadriceps tendon rupture of the contralateral knee following simultaneous bilateral knee replacement in a case of inflammatory arthritis patient. End to end repair for Quadriceps tear and augmentation with Autologous Hamstring tendon graft was done for Patella tendon rupture. OUTCOME: Patient was followed up for a period of 1 year and there was no Extension lag with a flexion of 100 degrees in both the knees. DISCUSSION: The key learning points and important aspects of diagnosing these injuries early and the management techniques are described in this unique case of bilateral extensor mechanism disruption following knee replacements.

  3. Orthotopic Transplantation of Achilles Tendon Allograft in Rats: With or without Incorporation of Autologous Mesenchymal Stem Cells.

    Science.gov (United States)

    Aynardi, Michael; Zahoor, Talal; Mitchell, Reed; Loube, Jeffrey; Feltham, Tyler; Manandhar, Lumanti; Paudel, Sharada; Schon, Lew; Zhang, Zijun

    2018-02-01

    The biology and function of orthotopic transplantation of Achilles tendon allograft are unknown. Particularly, the revitalization of Achilles allograft is a clinical concern. Achilles allografts were harvested from donor rats and stored at -80 °C. Subcutaneous adipose tissue was harvested from the would-be allograft recipient rats for isolation of mesenchymal stem cells (MSCs). MSCs were cultured with growth differentiation factor-5 (GDF-5) and applied onto Achilles allografts on the day of transplantation. After the native Achilles tendon was resected from the left hind limb of the rats, Achilles allograft, with or without autologous MSCs, was implanted and sutured with calf muscles proximally and calcaneus distally. Animal gait was recorded presurgery and postsurgery weekly. The animals were sacrificed at week 4, and the transplanted Achilles allografts were collected for biomechanical testing and histology. The operated limbs had altered gait. By week 4, the paw print intensity, stance time, and duty cycle (percentage of the stance phase in a step cycle) of the reconstructed limbs were mostly recovered to the baselines recorded before surgery. Maximum load of failure was not different between Achilles allografts, with or without MSCs, and the native tendons. The Achilles allograft supplemented with MSCs had higher cellularity than the Achilles allograft without MSCs. Deposition of fine collagen (type III) fibers was active in Achilles allograft, with or without MSCs, but it was more evenly distributed in the allografts that were incubated with MSCs. In conclusion, orthotopically transplanted Achilles allograft healed with host tissues, regained strength, and largely restored Achilles function in 4 wk in rats. It is therefore a viable option for the reconstruction of a large Achilles tendon defect. Supplementation of MSCs improved repopulation of Achilles allograft, but large animal models, with long-term follow up and cell tracking, may be required to fully

  4. Flexor tendon lacerations in zone V.

    Science.gov (United States)

    Stefanich, R J; Putnam, M D; Peimer, C A; Sherwin, F S

    1992-03-01

    Twenty-three patients with zone V flexor tendon lacerations rehabilitated by the Kleinert protocol were studied at an average of 46 months after trauma. Hand function was subjectively normal in only eight. Of fourteen patients who were employed at the time of injury, eight returned to their original occupations. Eight others were working at other jobs, and we considered six more capable of employment. Only one had a poor functional result that precluded occupational use of the hand. Pinch/grip strengths recovered to 85%/79% of the uninvolved side. Independent flexor digitorum superficialis/flexor digitorum profundus action was present in only seven patients. Sixteen regained full digital flexion. Extension loss averaged 25% at the wrist and 10% in each digit. As assessed by static two-point discrimination, sensibility was poor after associated median and ulnar nerve transections; this did not preclude good objective functional results. Complications included two tendon ruptures, proximal interphalangeal hyperextension in the presence of an unrepaired flexor digitorum superficialis, and limited motion in two patients after poor compliance in therapy. Tenolysis was needed in 4 of the 23. We now use a modified Duran technique for noncompliant patients and in those who are unable to extend their PIP joints because of weak intrinsic muscles.

  5. Fetal development of the pulley for muscle insertion tendons: A review and new findings related to the tensor tympani tendon.

    Science.gov (United States)

    Rodríguez-Vázquez, Jose Francisco; Honkura, Yohei; Katori, Yukio; Murakami, Gen; Abe, Hiroshi

    2017-01-01

    The existence of hard tissue pulleys that act to change the direction of a muscle insertion tendon is well known in the human body. These include (1) the trochlea for the extraocular obliquus superior muscle, (2) the pterygoid hamulus for the tensor veli palatini muscle, (3) the deep sulcus on the plantar aspect of the cuboid bone for the peroneus longus tendon, (4) the lesser sciatic notch for the obturator internus muscle, and (5) the bony trochleariformis process for the tensor tympani muscle tendon. In addition, (6) the stapedius muscle tendon shows a lesser or greater angulation at the pyramidal eminence of the temporal bone. Our recent studies have shown that the development of pulleys Nos. 1 and 2 can be explained by a change in the topographical relationship between the pulley and the tendon, that of pulley No. 3 by the rapidly growing calcaneus pushing the tendon, and that of pulley No. 4 by migration of the insertion along the sciatic nerve and gluteus medius tendon. Therefore, in Nos. 1-4, an initially direct tendon curves secondarily and obtains an attachment to the pulley. In case No. 6, the terminal part of the stapedius tendon originates secondarily from the interzone mesenchymal tissue of the incudostapedial joint. In the case of pulley No. 5, we newly demonstrated that its initial phase of development was similar to No. 6, but the tensor tympani tendon achieved a right-angled turn under guidance by a specific fibrous tissue and it migrated along the growing malleus manubrium. Copyright © 2016 Elsevier GmbH. All rights reserved.

  6. Endogenous growth hormone and insulin after interposition of a reversed jejunal segment in short bowel syndrome. An experimental study on pigs

    Directory of Open Access Journals (Sweden)

    Papamichail Michail

    2012-08-01

    Full Text Available Abstract Background Interposition of a reversed jejunal loop in short bowel sydrome has previously been investigated in human along with animal models and seemed able to facilitate intestinal adaptation. However, it is unclear if growth hormone and insulin, well known for their implication in short bowel pathophysiology, intervene on this effect. Findings Porcine models were randomly allocated to two cohorts: (1 short bowel (SB group (n = 8 and (2 short bowel reverse jejunal segment (SB-RS group (n = 8. Amongst other parameters serum growth hormone and insulin were measured at baseline, as well as on postoperative day 30 and 60. Conclusion Both endogenous hormones failed to demonstrate significant difference in respect to potential direct effect to mechanisms of enhanced intestinal adaptation in reversed group

  7. Climate Reconstructions

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NOAA Paleoclimatology Program archives reconstructions of past climatic conditions derived from paleoclimate proxies, in addition to the Program's large holdings...

  8. Bevacizumab Improves Achilles Tendon Repair in a Rat Model

    Directory of Open Access Journals (Sweden)

    Herbert Tempfer

    2018-04-01

    Full Text Available Background/Aims: Effective wound-healing generally requires efficient re-vascularization after injury, ensuring sufficient supply with oxygen, nutrients, and various cell populations. While this applies to most tissues, tendons are mostly avascular in nature and harbor relatively few cells, probably contributing to their poor regenerative capacity. Considering the minimal vascularization of healthy tendons, we hypothesize that controlling angiogenesis in early tendon healing is beneficial for repair tissue quality and function. Methods: To address this hypothesis, Bevacizumab, a monoclonal antibody blocking VEGF-A signaling, was locally injected into the defect area of a complete tenotomy in rat Achilles tendon. At 28 days post-surgery, the defect region was investigated using immunohistochemistry against vascular and lymphatic epitopes. Polarization microscopy and biomechanical testing was used to determine tendon integrity and gait analysis for functional testing in treated vs non-treated animals. Results: Angiogenesis was found to be significantly reduced in the Bevacizumab treated repair tissue, accompanied by significantly reduced cross sectional area, improved matrix organization, increased stiffness and Young’s modulus, maximum load and stress. Further, we observed an improved gait pattern when compared to the vehicle injected control group. Conclusion: Based on the results of this study we propose that reducing angiogenesis after tendon injury can improve tendon repair, potentially representing a novel treatment-option.

  9. Tendon shift in hallux valgus: observations at MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Eustace, S. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Williamson, D. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States); Wilson, M. [Department of Orthopedics, Brigham and Womens Hospital, Boston, Massachusetts (United States); O`Byrne, J. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Bussolari, L. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States); Thomas, M. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States); Stephens, M. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Stack, J. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Weissman, B. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States)

    1996-08-01

    Objective. This study was undertaken to demonstrate a shift in tendon alignment at the first metatarsophalangeal joint in patients with hallux valgus by means of magnetic resonance imaging. Design. Ten normal feet and 20 feet with the hallux valgus deformity conforming to conventional clinical and radiographic criteria were prospectively studied using magnetic resonance imaging. Correlation was made between tendon position at the first metatarsophalangeal joint and the severity of the hallux valgus deformity. Results. There is a significant shift in tendon position at the first metatarsophalangeal joint of patients with hallux valgus. The insertion of the abductor hallucis tendon is markedly plantarward and the flexor and extensor tendons bowstring at the first metatarsophalangeal joint compared with patients without the deformity. The severity of the tendon shift correlates with the hallux valgus angle and clinical severity of the hallux valgus deformity in each case. Conclusion. Patients with hallux valgus have a significant tendon shift at the first metatarsophalangeal joint which appears to contribute to development of the deformity. (orig.). With 4 figs., 1 tab.

  10. Tendon shift in hallux valgus: observations at MR imaging

    International Nuclear Information System (INIS)

    Eustace, S.; Williamson, D.; Wilson, M.; O'Byrne, J.; Bussolari, L.; Thomas, M.; Stephens, M.; Stack, J.; Weissman, B.

    1996-01-01

    Objective. This study was undertaken to demonstrate a shift in tendon alignment at the first metatarsophalangeal joint in patients with hallux valgus by means of magnetic resonance imaging. Design. Ten normal feet and 20 feet with the hallux valgus deformity conforming to conventional clinical and radiographic criteria were prospectively studied using magnetic resonance imaging. Correlation was made between tendon position at the first metatarsophalangeal joint and the severity of the hallux valgus deformity. Results. There is a significant shift in tendon position at the first metatarsophalangeal joint of patients with hallux valgus. The insertion of the abductor hallucis tendon is markedly plantarward and the flexor and extensor tendons bowstring at the first metatarsophalangeal joint compared with patients without the deformity. The severity of the tendon shift correlates with the hallux valgus angle and clinical severity of the hallux valgus deformity in each case. Conclusion. Patients with hallux valgus have a significant tendon shift at the first metatarsophalangeal joint which appears to contribute to development of the deformity. (orig.). With 4 figs., 1 tab

  11. Collateral ligament reconstruction of the chronic thumb injury with bio-tenodesis screw fixation

    DEFF Research Database (Denmark)

    Gvozdenovic, Robert; Boeckstyns, Michel

    2014-01-01

    We describe a new technique for the reconstruction of chronic lesions of the collateral ligaments of the metacarpophalangeal ligaments of the thumb, using a Bio-Tenodesis screw for the fixation of a tendon graft in a triangular manner with proximal apex and allowing early mobilization, starting 2...

  12. [Current problems in the reconstructive surgery of the locomotor apparatus in children].

    Science.gov (United States)

    Kupatadze, D D; Nabokov, V V; Malikov, S A; Polozov, R N; Kanina, L Ia; Veselov, A G

    1997-01-01

    The authors analyze results of treatment of 778 children with malignant and benign tumors of the bones, pseudoarthroses, amputations of lower extremities and fingers, injuries of the tendons, vessels and contused-lacerated wounds of distal phalanges of fingers. The possibility to use a precision technique for the reconstructive operations of the vessels in children is shown.

  13. Disorders of the long head of the biceps tendon.

    Science.gov (United States)

    Sethi, N; Wright, R; Yamaguchi, K

    1999-01-01

    Without a clear understanding of the functional role of the biceps tendon, treatment recommendations have been a subject of controversy. An objective review of the available information would suggest that some humeral head stability may be imparted through the tendon. However, the magnitude of this function is likely to be small and possibly insignificant. In contrast, the symptomatic significance of the long head of the biceps is less controversial, and it has become increasingly recognized as an important source of persistent shoulder pain when not specifically addressed. When present, persistent pain from the long head of the biceps is likely to have more negative functional consequences than loss of the tendon itself. Given these concerns, evaluation and treatment of patients with long head of the biceps disorders should be individualized, based on the likelihood that biceps-related pain will resolve. Although not universally accepted, we recommend tenodesis of the long head of the biceps in those cases in which there are either chronic inflammatory or structural changes, which would make it unlikely that the pain would resolve. These clinical situations in which tenodesis would be required include greater than 25% partial thickness tearing of the tendon, chronic atrophic changes of the tendon, any luxation of the biceps tendon from the bicipital groove, any disruption of associated bony or ligamentous anatomy of the bicipital groove that would make autotenodesis likely (i.e., 4-part fracture), and any significant reduction or atrophy of the size of the tendon that is more than 25% of the normal tendon width. Relative indications for biceps tenodesis also include biceps disease in the context of a failed decompression for rotator cuff tendinitis. It should be emphasized that routine tenodesis is not recommended during operative treatment for the rotator cuff. Rather, we avoid tenodesis whenever it is believed that inflammatory changes to the biceps tendon are

  14. Stimulation of tendon repair by platelet concentrate, CDMP-2 and mechanical loading in animal models

    OpenAIRE

    Virchenko, Olena

    2007-01-01

    Growth factor delivery may be useful to accelerate the rate of tendon healing. We studied Platelet Concentrate, which in effect can be regarded as a cocktail of growth factors relevant for tendon healing. In a rat Achilles tendon transection model, one postoperative injection of Platelet Concentrate resulted in increased strength even 3 weeks later. Mechanical stimulation improves the repair of ruptured tendons. We studied the effects of platelets upon Achilles tendon regenerates in rats 3, 5...

  15. Tendon neuroplastic training: changing the way we think about tendon rehabilitation: a narrative review

    OpenAIRE

    Rio, Ebonie; Kidgell, Dawson; Moseley, G Lorimer; Gaida, Jamie; Docking, Sean; Purdam, Craig; Cook, Jill

    2015-01-01

    Tendinopathy can be resistant to treatment and often recurs, implying that current treatment approaches are suboptimal. Rehabilitation programmes that have been successful in terms of pain reduction and return to sport outcomes usually include strength training. Muscle activation can induce analgesia, improving self-efficacy associated with reducing one's own pain. Furthermore, strength training is beneficial for tendon matrix structure, muscle properties and limb biomechanics. However, curre...

  16. Complete rupture of the long head of the biceps tendon and the distal biceps tendon

    Directory of Open Access Journals (Sweden)

    Pieter J. Oberholzer

    2014-12-01

    Full Text Available The most common injury to the biceps muscle is rupture of the long head of the biceps tendon. A tear can occur proximally, distally or at the musculotendinous junction. Two cases are discussed, in both of which the patients felt a sudden sharp pain in the upper arm, at the shoulder and elbow respectively, and presented with a biceps muscle bump (Popeye deformity.

  17. Tendon collagen synthesis declines with immobilization in elderly humans

    DEFF Research Database (Denmark)

    Dideriksen, Kasper; Boesen, Anders P; Reitelseder, Søren

    2017-01-01

    -80 yr) were randomly assigned to NSAIDs (ibuprofen 1,200 mg/day; Ibu) or placebo (Plc). One lower limb was immobilized in a cast for 2 wk and retrained for 6 wk. Tendon collagen protein synthesis, mechanical properties, size, expression of genes related to collagen turnover and remodeling, and signal...... intensity (from magnetic resonance imaging) were investigated. Tendon collagen synthesis decreased (P ... immobilization in both groups, whereas scleraxis mRNA decreased with inactivity in the Plc group only (P collagen protein synthesis decreased after 2 wk of immobilization, whereas tendon stiffness and modulus were only marginally reduced, and NSAIDs had no influence upon this...

  18. Ultrasound-based testing of tendon mechanical properties

    DEFF Research Database (Denmark)

    Seynnes, O R; Bojsen-Møller, J.; Albracht, K

    2015-01-01

    In the past 20 years, the use of ultrasound-based methods has become a standard approach to measure tendon mechanical properties in vivo. Yet the multitude of methodological approaches adopted by various research groups probably contribute to the large variability of reported values. The technique......, or signal synchronization; and 2) in physiological considerations related to the viscoelastic behavior or length measurements of tendons. Hence, the purpose of the present review is to assess and discuss the physiological and technical aspects connected to in vivo testing of tendon mechanical properties...

  19. The Improvement of Bone-Tendon Fixation by Porous Titanium Interference Screw: A Rabbit Animal Model.

    Science.gov (United States)

    Tsai, Pei-I; Chen, Chih-Yu; Huang, Shu-Wei; Yang, Kuo-Yi; Lin, Tzu-Hung; Chen, San-Yuan; Sun, Jui-Sheng

    2018-05-04

    The interference screw is a widely used fixation device in the anterior cruciate ligament (ACL) reconstruction surgeries. Despite the generally satisfactory results, problems of using interference screws were reported. By using additive manufacturing (AM) technology, we developed an innovative titanium alloy (Ti 6 Al 4 V) interference screw with rough surface and inter-connected porous structure designs to improve the bone-tendon fixation. An innovative Ti 6 Al 4 V interference screws were manufactured by AM technology. In vitro mechanical tests were performed to validate its mechanical properties. Twenty-seven New Zealand white rabbits were randomly divided into control and AM screw groups for biomechanical analyses and histological analysis at 4, 8 and 12 weeks postoperatively; while micro-CT analysis was performed at 12 weeks postoperatively. The biomechanical tests showed that the ultimate failure load in the AM interference screw group was significantly higher than that in the control group at all tested periods. These results were also compatible with the findings of micro-CT and histological analyses. In micro-CT analysis, the bone-screw gap was larger in the control group; while for the additive manufactured screw, the screw and bone growth was in close contact. In histological study, the bone-screw gaps were wider in the control group and were almost invisible in the AM screw group. The innovative AM interference screws with surface roughness and inter-connected porous architectures demonstrated better bone-tendon-implant integration, and resulted in stronger biomechanical characteristics when compared to traditional screws. These advantages can be transferred to future interference screw designs to improve their clinical performance. The AM interference screw could improve graft fixation and eventually result in better biomechanical performance of the bone-tendon-screw construct. The innovative AM interference screws can be transferred to future

  20. Icariin Promotes Tendon-Bone Healing during Repair of Rotator Cuff Tears: A Biomechanical and Histological Study.

    Science.gov (United States)

    Ye, Chenyi; Zhang, Wei; Wang, Shengdong; Jiang, Shuai; Yu, Yuanbin; Chen, Erman; Xue, Deting; Chen, Jianzhong; He, Rongxin

    2016-10-25

    To investigate whether the systematic administration of icariin (ICA) promotes tendon-bone healing after rotator cuff reconstruction in vivo, a total of 64 male Sprague Dawley rats were used in a rotator cuff injury model and underwent rotator cuff reconstruction (bone tunnel suture fixation). Rats from the ICA group ( n = 32) were gavage-fed daily with ICA at 0.125 mg/g, while rats in the control group ( n = 32) received saline only. Micro-computed tomography, biomechanical tests, serum ELISA (calcium; Ca, alkaline phosphatase; AP, osteocalcin; OCN) and histological examinations (Safranin O and Fast Green staining, type I, II and III collagen (Col1, Col2, and Col3), CD31, and vascular endothelial growth factor (VEGF)) were analyzed two and four weeks after surgery. In the ICA group, the serum levels of AP and OCN were higher than in the control group. More Col1-, Col2-, CD31-, and VEGF-positive cells, together with a greater degree of osteogenesis, were detected in the ICA group compared with the control group. During mechanical testing, the ICA group showed a significantly higher ultimate failure load than the control group at both two and four weeks. Our results indicate that the systematic administration of ICA could promote angiogenesis and tendon-bone healing after rotator cuff reconstruction, with superior mechanical strength compared with the controls. Treatment for rotator cuff injury using systematically-administered ICA could be a promising strategy.

  1. Bone marrow-derived mesenchymal stem cells influence early tendon-healing in a rabbit achilles tendon model.

    Science.gov (United States)

    Chong, Alphonsus K S; Ang, Abel D; Goh, James C H; Hui, James H P; Lim, Aymeric Y T; Lee, Eng Hin; Lim, Beng Hai

    2007-01-01

    A repaired tendon needs to be protected for weeks until it has accrued enough strength to handle physiological loads. Tissue-engineering techniques have shown promise in the treatment of tendon and ligament defects. The present study tested the hypothesis that bone marrow-derived mesenchymal stem cells can accelerate tendon-healing after primary repair of a tendon injury in a rabbit model. Fifty-seven New Zealand White rabbits were used as the experimental animals, and seven others were used as the source of bone marrow-derived mesenchymal stem cells. The injury model was a sharp complete transection through the midsubstance of the Achilles tendon. The transected tendon was immediately repaired with use of a modified Kessler suture and a running epitendinous suture. Both limbs were used, and each side was randomized to receive either bone marrow-derived mesenchymal stem cells in a fibrin carrier or fibrin carrier alone (control). Postoperatively, the rabbits were not immobilized. Specimens were harvested at one, three, six, and twelve weeks for analysis, which included evaluation of gross morphology (sixty-two specimens), cell tracing (twelve specimens), histological assessment (forty specimens), immunohistochemistry studies (thirty specimens), morphometric analysis (forty specimens), and mechanical testing (sixty-two specimens). There were no differences between the two groups with regard to the gross morphology of the tendons. The fibrin had degraded by three weeks. Cell tracing showed that labeled bone marrow-derived mesenchymal stem cells remained viable and present in the intratendinous region for at least six weeks, becoming more diffuse at later time-periods. At three weeks, collagen fibers appeared more organized and there were better morphometric nuclear parameters in the treatment group (p tendon repair can improve histological and biomechanical parameters in the early stages of tendon-healing.

  2. TGIF1 Gene Silencing in Tendon-Derived Stem Cells Improves the Tendon-to-Bone Insertion Site Regeneration

    Directory of Open Access Journals (Sweden)

    Liyang Chen

    2015-11-01

    Full Text Available Background/Aims: The slow healing process of tendon-to-bone junctions can be accelerated via implanted tendon-derived stem cells (TDSCs with silenced transforming growth interacting factor 1 (TGIF1 gene. Tendon-to-bone insertion site is the special form of connective tissues derivatives of common connective progenitors, where TGF-β plays bidirectional effects (chondrogenic or fibrogenic through different signaling pathways at different stages. A recent study revealed that TGF-β directly induces the chondrogenic gene Sox9. However, TGIF1 represses the expression of the cartilage master Sox9 gene and changes its expression rate against the fibrogenesis gene Scleraxis (Scx. Methods: TGIF1 siRNA was transduced or TGIF1 was over-expressed in tendon-derived stem cells. Following suprapinatus tendon repair, rats were either treated with transduced TDSCs or nontransduced TDSCs. Histologic examination and Western blot were performed in both groups. Results: In this study, the silencing of TGIF1 significantly upregulated the chondrogenic genes and markers. Similarly, TGIF1 inhibited TDSC differentiation into cartilage via interactions with TGF-β-activated Smad2 and suppressed the phosphorylation of Smad2. The area of fibrocartilage at the tendon-bone interface was significantly increased in the TGIF1 (- group compared with the control and TGIF1-overexpressing groups in the early stages of the animal model. The interface between the tendon and bone showed a increase of new bone and fibrocartilage in the TGIF1 (- group at 4 weeks. Fibrovascular scar tissue was observed in the TGIF1-overexpressing group and the fibrin glue only group. Low levels of fibrocartilage and fibrovascular scar tissue were found in the TDSCs group. Conclusion: Collectively, this study shows that the tendon-derived stem cell modified with TGIF1 gene silencing has promising effects on tendon-to-bone healing which can be further explored as a therapeutic tool in regenerative medicine.

  3. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons.

    Science.gov (United States)

    Thorpe, Chavaunne T; Godinho, Marta S C; Riley, Graham P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2015-12-01

    While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Powered AFO for Achilles tendon rupture.

    Science.gov (United States)

    Yoshizawa, Nobuyuki

    2008-01-01

    This paper proposes a powered ankle foot orthosis (AFO) for the treatment of a ruptured Achilles tendon. Usually, conservative orthosis treatment requires about two months, and a motionless ankle degrades activities of daily living (ADL). It is difficult to go to school or work on foot, and a pair of crutches is needed to go up and down stairs. In order to improve the ADL, an electric powered AFO has been designed to improve the ability to walk with a fixed ankle joint. The sole of the proposed AFO is equipped with an electric actuator. The prototype actuator consists of Nd magnets and electromagnets and is lightweight and battery driven. The actuator can switch the upright posture and the stepped forward posture of the patient. In an experiment, the use of this electric AFO made it possible to walk and to ascend and descend stairs with a fixed ankle joint.

  5. Tension Stiffened and Tendon Actuated Manipulator

    Science.gov (United States)

    Doggett, William R. (Inventor); Dorsey, John T. (Inventor); Ganoe, George G. (Inventor); King, Bruce D. (Inventor); Jones, Thomas C. (Inventor); Mercer, Charles D. (Inventor); Corbin, Cole K. (Inventor)

    2015-01-01

    A tension stiffened and tendon actuated manipulator is provided performing robotic-like movements when acquiring a payload. The manipulator design can be adapted for use in-space, lunar or other planetary installations as it is readily configurable for acquiring and precisely manipulating a payload in both a zero-g environment and in an environment with a gravity field. The manipulator includes a plurality of link arms, a hinge connecting adjacent link arms together to allow the adjacent link arms to rotate relative to each other and a cable actuation and tensioning system provided between adjacent link arms. The cable actuation and tensioning system includes a spreader arm and a plurality of driven and non-driven elements attached to the link arms and the spreader arm. At least one cable is routed around the driven and non-driven elements for actuating the hinge.

  6. Anatomical reconstruction of the fourth brachymetatarsia with one-stage iliac bone and cartilage cap grafting.

    Science.gov (United States)

    Woo, Sang Hyun; Bang, Chi Young; Ahn, Hee-Chan; Kim, Sung-Jung; Choi, Jun-Young

    2017-05-01

    We present a one-stage procedure for lengthening the fourth brachymetatarsia with autogenous iliac bone and cartilage cap grafting for the anatomical reconstruction of the metatarsophalangeal (MTP) joint METHODS: During the last 8 years, 56 feet in 41 patients with congenital brachymetatarsia of the fourth toe were corrected with a one-stage operation to reposition the articular cartilage cap to the distal part of interpositional iliac bone graft at the metatarsal epiphysis. The length of the harvested iliac bone graft was 22.9 mm on average. The mean fixation period was 58.5 days, and the mean gain in length and percentage increase was 20.9 mm and 39%, respectively. MRI showed a stable MTP joint over viable cartilage cap in 83.3% of the cases. Mean postoperative American Orthopedic Foot and Ankle Society lesser MTP-interphalangeal score was 82.0. Neither neurovascular impairment nor recurrence of brachymetatarsia occurred in the mean follow-up period of 43.6 months. All patients were satisfied with the postoperative cosmetic results. Thirteen patients (23.2%) complained of limited active dorsiflexion of the fourth toe, and extensor adhesion was released by extensor tenolysis in only one patient. In a single case of nonunion at the bone graft site, additional surgery was not necessary. Anatomical reconstruction of the fourth brachymetatarsia with one-stage interpositional iliac bone and cartilage cap grafting resulted in excellent cosmetic results and a physiologic MTP joint, providing the benefits of one-stage lengthening with a low complication rate. Therapeutic, IV. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. The 'bridging sign', a MR finding for combined full-thickness tears of the subscapularis tendon and the supraspinatus tendon

    International Nuclear Information System (INIS)

    Jung, Jin Young; Yoon, Young Cheol; Cha, Dong Ik; Yoo, Jae-Chul; Jung, Jee Young

    2013-01-01

    Background: In daily practice, we discovered one of the secondary magnetic resonance (MR) findings of the subscapularis (SSC) tendon tear, the 'bridging sign', which has not been previously described. Purpose: To describe the 'bridging sign' on shoulder MR imaging and its radiological and clinical significance in patients with SSC tendon tear. Material and Methods: Twenty-nine patients who had undergone shoulder arthroscopy and had full-thickness tear of the subscapularis tendon were enrolled. The medical records of the 29 patients were retrospectively reviewed for the duration of shoulder pain, rotator cuff tears, and associated arthroscopic findings: biceps tendon abnormality and superior glenoid labral tear. Then, preoperative shoulder MR images were retrospectively reviewed for the presence or absence of the 'bridging sign' and associated MR findings: periarticular fluid and fatty atrophy of the supraspinatus and subscapularis muscles. The type of rotator cuff tear associated with the 'bridging sign' was assessed and the sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of a certain type of rotator cuff tear were calculated. Associated arthroscopic and MR findings and mean duration of the shoulder pain between the patients with and without the 'bridging sign' were compared. Results: The 'bridging sign' was seen in 17 of 29 patients and corresponded to a complex of the torn and superomedially retracted subscapularis tendon, coracohumeral ligament, and superior glenohumeral ligament, adhered to the anterior margin of the torn supraspinatus (SSP) tendon on arthroscopy. All patients with the 'bridging sign' had combined full-thickness tear (FTT) of the cranial 1/2 portion of the subscapularis tendon and anterior 1/2 portion of the SSP tendon. The sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of combined FTTs of the SSC tendon and anterior portion of the SSP tendon were 81.0%, 100%, and 86

  8. Comparing Dimensions of Four-Strand Hamstring Tendon Grafts with Native Anterior and Posterior Cruciate Ligaments

    Directory of Open Access Journals (Sweden)

    Barış Yılmaz

    2016-01-01

    Full Text Available Background. The aim of the study was to evaluate whether or not there was any incompatibility between four-strand hamstring tendons taken from the same knee and the dimensions of the ACL and PCL. Methods. 15 fresh frozen cadaver hamstrings were prepared as four-strand grafts and measurements made of the ACL and PCL circumferences in the midsection were made in the narrowest part of the midsection. The cross-section areas and diameters were calculated with geometric calculations used to measure the cross-sectional area of cylinders. Accepting that the geometric insertions were elliptical, the length, width, and area were calculated for entry areas. Results. A significant relationship at 96.2% was determined between the ACL mid and the hamstring diameter. A significant relationship at 96.7% was determined between the ACL and the hamstring mid area. A significant relationship at 96.4% was determined between the PCL mid and the hamstring diameter. A significant relationship at 95.7% was determined between the PCL and the hamstring mid area. Conclusion. For the reconstruction of ACL and PCL, it was determined that there is less incompatibility between the four-strand hamstring tendons taken from the same knee and the dimensions of the midsection PCL compared to the ACL dimensions.

  9. The effects of test environment and cyclic stretching on the failure properties of human patellar tendons

    International Nuclear Information System (INIS)

    Haut, R.C.; Powlison, A.C.

    1990-01-01

    There is a need to document the mechanical properties of patellar tendon allografts used for reconstructive surgery of the damaged anterior cruciate ligament, especially the effects of irradiation sterilization. The purpose of this study was to investigate the influences of in vitro test environment and low-level cyclic stretching prior to failure tests on nonirradiated and irradiated human graft tissues. Bilateral patellar tendons were split and each half processed accordingly. Some graft tissues were stretched cyclically at 2.5 mm deformation before failure. Experiments were performed in a 37 degrees C saline bath or with tissues moistened with a drip of the same. The irradiated grafts relaxed less and generated less slack length in the drip environment than the nonirradiated controls. Cyclic stretching did not alter failure characteristics of either graft tissue. While no significant differences in the tensile responses or failure characteristics were noted for irradiated and nonirradiated grafts in the drip, in the bath environment the nonirradiated tissues had greater strength and modulus. This resulted in there being a significant difference between irradiated and nonirradiated tissue responses in a heated saline bath environment. These experimental results exemplify the need to control in vitro test environments in the evaluation of various sterilization and preservation protocols for soft tissue allografts

  10. Region specific patella tendon hypertrophy in humans following resistance training

    DEFF Research Database (Denmark)

    Kongsgaard, M.; Reitelseder, S; Pedersen, T.G.

    2007-01-01

    AIM: To examine if cross-sectional area (CSA) differs along the length of the human patellar tendon (PT), and if there is PT hypertrophy in response to resistance training. METHODS: Twelve healthy young men underwent baseline and post-training assessments. Maximal isometric knee extension strength...... (MVC) was determined unilaterally in both legs. PT CSA was measured at the proximal-, mid- and distal PT level and quadriceps muscle CSA was measured at mid-thigh level using magnetic resonance imaging. Mechanical properties of the patellar tendons were determined using ultrasonography. Subsequently....... CONCLUSIONS: To our knowledge, this study is the first to report tendon hypertrophy following resistance training. Further, the data show that the human PT CSA varies along the length of the tendon....

  11. Surgical treatment of partial biceps tendon ruptures at the elbow.

    Science.gov (United States)

    Dellaero, David T; Mallon, William J

    2006-01-01

    We present the treatment and results of a consecutive series of 7 patients (mean age, 42.7 years) with partial ruptures of the distal biceps tendon. All injuries occurred as the result of either heavy labor or weightlifting. Diagnosis in all cases was made with magnetic resonance imaging. After failure of conservative therapy, the patients were treated with repair of the distal biceps tendon. Mean follow-up was 30.6 months (range, 25-39 months). Results were uniformly good, with all patients satisfied with the outcome. All patients maintained their preoperative range of motion, with none reporting significant postoperative pain. The only complication was transient neurapraxias of the lateral antebrachial cutaneous nerve in 2 cases. We conclude that patients presenting with chronic pain in the cubital fossa should be evaluated for possible partial biceps tendon tear. If the diagnosis of partial tendon tear is made, surgical repair is a safe and effective method of treatment.

  12. Magnetic resonance imaging of Achilles tendon xanthomas in familial hypercholesterolemia

    International Nuclear Information System (INIS)

    Liem, M.S.L.; Bloem, J.L.; Schipper, J.

    1992-01-01

    The demonstration of tendon xanthomas is helpful in diagnosing heterozygous familial hypercholesterolemia. We investigated the possibility the lipid element with magnetic resonance (MR) imaging in seven patients with familial hypercholesterolemia and six controls. Although the mean relative signal intensities measured on long TR/TE spin echo sequences of the tendon were significantly higher in patients than in controls, the lack of such elevation does not rule out the presence of such lesions. MR imaging and US provide equal information on the anatomy of the Achilles tendon; as an abnormally increased signal intensity within the xanthoma on MRI was found in only a minority of our patients, the value of MRI in the demonstration of Achilles tendon xanthomas is limited when using conventional T1 and T2 spin echo sequences. (orig./DG)

  13. Bilateral giant cell tumor of tendon sheath of tendoachilles

    Directory of Open Access Journals (Sweden)

    Soma Datta

    2014-01-01

    Full Text Available Giant cell tumor of tendon sheath arises from the synovium of tendon sheaths, joints, or bursae, mostly affects adults between 30 and 50 years of age, and is slightly more common in females. We report the case of a 32-years-old male presenting with pain in both ankles without any history of trauma. On clinical examination, tenderness on both tendoachilles and local thickening were observed. Ultrasonography showed thickening of local tendinous area with increase in anteroposterior diameter, and Doppler demonstrated increased flow in peritendinous area. MRI findings showed that most of the tumor had intermediate signal intensity and portions of the tumor had low signal intensity. Fine needle aspiration cytology confirmed the diagnosis of giant cell tumor of tendon sheath. Excision biopsy was done with no recurrence on five month follow-up. Review of literature did not reveal any similar result; so, bilateral giant cell tumor of tendon sheath of tendoachilles is a rare presentation.

  14. CT of peroneal tendon injury in patients with calcaneal fractures

    International Nuclear Information System (INIS)

    Rosenberg, Z.S.; Feldman, F.; Singson, R.D.

    1986-01-01

    Injury to the peroneal tendons is a major complication of intraarticular calcaneal fractures. Heretofore, the injury has been difficult to diagnose by routine imaging modalities. However, CT studies of 24 intraarticular calcaneal fractures revealed evidence of peroneal tendon injury in 22 cases. The pathologic conditions included lateral displacement, subluxation, dislocation, and impingement on the tendons by bony fragments, hematomas, and scar tissue. Patients studied 6-12 months after injury had CT evidence consistent with clinical symptoms of peroneal tenosynovitis. Since peroneal tendon injury is surgically correctable, it should be differentiated from other known and more obvious complications, of calcaneal fractures. CT therefore serves as a valuable, noninvasive tool in evaluating these otherwise nonvisualized soft tissue structures in the immediate posttraumatic period as well as during long-term follow up

  15. Corticospinal excitability changes following prolonged muscle tendon vibration

    NARCIS (Netherlands)

    Steyvers, M.; Levin, O.; Baelen, M.G.M. van; Swinnen, S.P.

    2003-01-01

    The present experiment addressed the time course of corticospinal excitability changes following interventional muscle tendon vibration. Using transcranial magnetic stimulation, motor evoked potentials of the flexor carpi radialis and extensor carpi radialis brevis muscle were recorded for a period

  16. Extracellular matrix adaptation of tendon and skeletal muscle to exercise

    DEFF Research Database (Denmark)

    Kjaer, Michael; Magnusson, Peter; Krogsgaard, Michael

    2006-01-01

    The extracellular matrix (ECM) of connective tissues enables linking to other tissues, and plays a key role in force transmission and tissue structure maintenance in tendons, ligaments, bone and muscle. ECM turnover is influenced by physical activity, and both collagen synthesis and metalloprotease......-beta and IL-6 is enhanced following exercise. For tendons, metabolic activity (e.g. detected by positron emission tomography scanning), circulatory responses (e.g. as measured by near-infrared spectroscopy and dye dilution) and collagen turnover are markedly increased after exercise. Tendon blood flow...... is regulated by cyclooxygenase-2 (COX-2)-mediated pathways, and glucose uptake is regulated by specific pathways in tendons that differ from those in skeletal muscle. Chronic loading in the form of physical training leads both to increased collagen turnover as well as to some degree of net collagen synthesis...

  17. A rare knee extensor mechanism injury: Vastus intermedius tendon rupture

    Directory of Open Access Journals (Sweden)

    Engin Cetinkaya

    2015-01-01

    Conclusion: We report the first case of isolated rupture of the vastus intermedius tendon in the literature and we claim that disorder may be succesfully treated with conservative treatment and adequate physiotheraphy.

  18. [Achilles tendon xanthoma imaging on ultrasound and magnetic resonance imaging].

    Science.gov (United States)

    Fernandes, Eloy de Ávila; Santos, Eduardo Henrique Sena; Tucunduva, Tatiana Cardoso de Mello; Ferrari, Antonio J L; Fernandes, Artur da Rocha Correa

    2015-01-01

    The Achilles tendon xanthoma is a rare disease and has a high association with primary hyperlipidemia. An early diagnosis is essential to start treatment and change the disease course. Imaging exams can enhance diagnosis. This study reports the case of a 60-year-old man having painless nodules on his elbows and Achilles tendons without typical gout crisis, followed in the microcrystalline disease clinic of Unifesp for diagnostic workup. Laboratory tests obtained showed dyslipidemia. The ultrasound (US) showed a diffuse Achilles tendon thickening with hypoechoic areas. Magnetic resonance imaging (MRI) showed a diffuse tendon thickening with intermediate signal areas, and a reticulate pattern within. Imaging studies showed relevant aspects to diagnose a xanthoma, thus helping in the differential diagnosis. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  19. Dextrose prolotherapy and corticosteroid injection into rat Achilles tendon.

    Science.gov (United States)

    Martins, C A Q; Bertuzzi, R T; Tisot, R A; Michelin, A F; do Prado, J M; Stroher, A; Burigo, M

    2012-10-01

    To assess the mechanical behavior and the histology of collagen fibers after prolotherapy with 12.5% dextrose into rat Achilles tendons and to compare with those of corticosteroid treatment. Out of 60 adult female Wistar rats (70 tendons), 15 received 12.5% dextrose (group I); 15 were treated with corticosteroid injection (group II); and 15 were given 0.9% saline injection (group III), all into the right Achilles tendon, whereas 13 animals received no injections (group IV). Three doses of each substance (groups I, II, and III) were given at a 5-day interval. Collagen fiber color was quantitatively assessed in three samples from each group and in five samples from the control group using picrosirius red staining under polarized and nonpolarized light. Twelve tendons from each group treated with the test substance and 20 tendons from the control group were submitted to the tensile strength test. There was no statistical difference across the groups with respect to maximum load at failure (n.s.) and absorbed energy (n.s.). With respect to tendon rupture, there was no difference between the myotendinous and the tendinous regions (n.s.). However, hematoxylin-eosin staining revealed statistical significance in lymphocytic inflammatory infiltrate (P = 0.008) and in parallel fiber orientation (P = 0.003) when comparing groups to the control group, without significance for either neovascularization (n.s.) or the presence of fibroblasts (n.s.). Likewise, there was no significant difference between the percentage of mature (n.s.) and immature (n.s.) fibers. Dextrose was not deleterious to the tendinous tissue, as it did not change the mechanical and histological properties of Achilles tendons in rats. The data obtained in this study may help clinicians in their daily work as they suggest that injections of 12.5% dextrose caused no harm to the tendons, although the clinical importance in humans still needs to be defined.

  20. Ultrasound Diagnosis of Bilateral Quadriceps Tendon Rupture After Statin Use

    Directory of Open Access Journals (Sweden)

    Nesselroade, Ryan D

    2010-09-01

    Full Text Available Simultaneous bilateral quadriceps tendon rupture is a rare injury. We report the case of bilateral quadriceps tendon rupture sustained with minimal force while refereeing a football game. The injury was suspected to be associated with statin use as the patient had no other identifiable risk factors.The diagnosis was confirmed using bedside ultrasound. [West J Emerg Med. 2010; 11(4:306-309.

  1. Sex Variation in Patellar Tendon Kinetics During Running

    Directory of Open Access Journals (Sweden)

    Sinclair Jonathan

    2015-06-01

    Full Text Available Purpose. The aim of the current investigation was to determine whether female recreational runners exhibit distinct patellar tendon loading patterns in relation to their male counterparts. Methods. Twelve male (age 26.55 ± 4.11 years, height 1.78 ± 0.11 m, mass 77.11 ± 5.06 kg and twelve female (age 26.67 ± 5.34 years, height 1.67 ± 0.12 m, mass 63.28 ± 9.75 kg runners ran over a force platform at 4.0 m · s-1. Lower limb kinematics were collected using an eight-camera optoelectric motion capture system which operated at 250 Hz. Patellar tendon loads were examined using a predictive algorithm. Sex differences in limb, knee and ankle joint stiffness were examined statistically using independent samples t tests. Results. The results indicate that patellar tendon force (male = 6.49 ± 2.28, female = 7.03 ± 1.35 and patelllar tendon loading rate (male = 92.41 ± 32.51, female = 111.05 ± 48.58 were significantly higher in female runners. Conclusions. Excessive tendon loading in female runners indicates that female runners may be at increased risk of patellar tendon pathologies.

  2. Association of gastrocnemius tendon calcification with chondrocalcinosis of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Foldes, K. [Department of Radiology, Veterans Administration Medical Center (VAMC), San Diego, CA (United States)]|[University of California San Diego Medical Center (UCSD), San Diego, CA (United States)]|[National Institute of Rheumatology and Physiotherapy, Budapest (Hungary); Lenchik, L. [Department of Radiology, Veterans Administration Medical Center (VAMC), San Diego, CA (United States)]|[University of California San Diego Medical Center (UCSD), San Diego, CA (United States); Jaovisidha, S. [Department of Radiology, Veterans Administration Medical Center (VAMC), San Diego, CA (United States)]|[University of California San Diego Medical Center (UCSD), San Diego, CA (United States); Clopton, P. [Department of Radiology, Veterans Administration Medical Center (VAMC), San Diego, CA (United States); Sartoris, D.J. [Department of Radiology, Veterans Administration Medical Center (VAMC), San Diego, CA (United States)]|[University of California San Diego Medical Center (UCSD), San Diego, CA (United States); Resnick, D. [Department of Radiology, Veterans Administration Medical Center (VAMC), San Diego, CA (United States)]|[University of California San Diego Medical Center (UCSD), San Diego, CA (United States)

    1996-10-01

    Objective. Chondrocalcinosis of the knee is a common radiological finding in the elderly. However, visualization of chondrocalcinosis may be difficult in patients with advanced cartilage loss.The purpose of this study was to determine sensitivity, specificity, and accuracy of gastrocnemius tendon calcification that might serve as a radiographic marker of chondrocalcinosis in patients with painful knees. Design and patients. We prospectively evaluated 37 knee radiographs in 30 consecutive patients (29 men, 8 women; mean age 67 years, age range 37-90 years) with painful knees who had radiographic evidence of chondrocalcinosis. The frequency of fibrocartilage, hyaline cartilage, and gastrocnemius tendon calcification was determined. For a control group, we evaluated knee radiographs in 65 consecutive patients with knee pain (54 men, 11 women; mean age 59 years, age range 40-93 years) who had no radiological signs of chondrocalcinosis. The frequency of gastrocnemius tendon calcification in the control group was determined. Results. Gastrocnemius tendon calcification was 41% sensitive, 100% specific, and 78% accurate in predicting chondrocalcinosis. The gastrocnemius tendon was calcified on 15 of 37 (41%) radiographs in the experimental group and on 0 of 67 radiographs in the control group. In the chondrocalcinosis group, 23 (62%) had posterior hyaline cartilage calcification, 14 (38%) had anterior hyaline cartilage calcification, 31 (84%) had medial meniscus calcification, and 36 (97%) had lateral meniscus calcification. Conclusions. Our results show that gastrocnemius tendon calcification is an accurate radiographic marker of chondrocalcinosis in patients with knee pain. (orig.). With 2 figs., 2 tabs.

  3. Association of gastrocnemius tendon calcification with chondrocalcinosis of the knee

    International Nuclear Information System (INIS)

    Foldes, K.; Lenchik, L.; Jaovisidha, S.; Clopton, P.; Sartoris, D.J.; Resnick, D.

    1996-01-01

    Objective. Chondrocalcinosis of the knee is a common radiological finding in the elderly. However, visualization of chondrocalcinosis may be difficult in patients with advanced cartilage loss.The purpose of this study was to determine sensitivity, specificity, and accuracy of gastrocnemius tendon calcification that might serve as a radiographic marker of chondrocalcinosis in patients with painful knees. Design and patients. We prospectively evaluated 37 knee radiographs in 30 consecutive patients (29 men, 8 women; mean age 67 years, age range 37-90 years) with painful knees who had radiographic evidence of chondrocalcinosis. The frequency of fibrocartilage, hyaline cartilage, and gastrocnemius tendon calcification was determined. For a control group, we evaluated knee radiographs in 65 consecutive patients with knee pain (54 men, 11 women; mean age 59 years, age range 40-93 years) who had no radiological signs of chondrocalcinosis. The frequency of gastrocnemius tendon calcification in the control group was determined. Results. Gastrocnemius tendon calcification was 41% sensitive, 100% specific, and 78% accurate in predicting chondrocalcinosis. The gastrocnemius tendon was calcified on 15 of 37 (41%) radiographs in the experimental group and on 0 of 67 radiographs in the control group. In the chondrocalcinosis group, 23 (62%) had posterior hyaline cartilage calcification, 14 (38%) had anterior hyaline cartilage calcification, 31 (84%) had medial meniscus calcification, and 36 (97%) had lateral meniscus calcification. Conclusions. Our results show that gastrocnemius tendon calcification is an accurate radiographic marker of chondrocalcinosis in patients with knee pain. (orig.). With 2 figs., 2 tabs

  4. Suture anchor tenodesis in repair of distal Achilles tendon injuries.

    Science.gov (United States)

    Kiliçoğlu, Onder; Türker, Mehmet; Yildız, Fatih; Akalan, Ekin; Temelli, Yener

    2014-01-01

    Distal Achilles tendon avulsions are in the form of either bony and nonbony avulsion of Achilles tendon from its calcaneal insertion. Four patients with distal Achilles tendon avulsions or ruptures which were treated with tendon to bone repair using suture anchors are presented here. Operated leg was immobilized in above-knee cast for 4 weeks while the patient walked non-weight-bearing. Then, cast was changed to below knee, and full weight-bearing was allowed. Patients underwent gait analysis minimum at first postoperative year. Mean American Orthopedics Foot Ankle Society ankle/hindfoot score of patients at last visit was 88.75 (range 85-100), and Achilles tendon total rupture score was 77.75 (range 58-87). Mean passive dorsiflexion of injured ankles (14° ± 5°) was lower than uninjured ankles (23° ± 9°). All the kinematic parameters of gait analysis were comparable to the uninjured side. Maximum plantar flexion power of injured ankle was 1.40 W/kg, and this was significantly lower than the contralateral side value 2.38 W/kg; (P = 0.0143). There were no visually altered gait or problems in daily life. Suture anchor tenodesis technique of distal Achilles tendon avulsions was successful in achieving durable osteotendinous repairs.

  5. The anatomical footprint of the Achilles tendon: a cadaveric study.

    Science.gov (United States)

    Ballal, M S; Walker, C R; Molloy, A P

    2014-10-01

    We dissected 12 fresh-frozen leg specimens to identify the insertional footprint of each fascicle of the Achilles tendon on the calcaneum in relation to their corresponding muscles. A further ten embalmed specimens were examined to confirm an observation on the retrocalcaneal bursa. The superficial part of the insertion of the Achilles tendon is represented by fascicles from the medial head of the gastrocnemius muscle, which is inserted over the entire width of the inferior facet of the calcaneal tuberosity. In three specimens this insertion was in continuity with the plantar fascia in the form of periosteum. The deep part of the insertion of the Achilles tendon is made of fascicles from the soleus tendon, which insert on the medial aspect of the middle facet of the calcaneal tuberosity, while the fascicles of the lateral head of the gastrocnemius tendon insert on the lateral aspect of the middle facet of the calcaneal tuberosity. A bicameral retrocalcaneal bursa was present in 15 of the 22 examined specimens. This new observation and description of the insertional footprint of the Achilles tendon and the retrocalcaneal bursa may allow a better understanding of the function of each muscular part of the gastrosoleus complex. This may have clinical relevance in the treatment of Achilles tendinopathies. ©2014 The British Editorial Society of Bone & Joint Surgery.

  6. Modified rerouting procedure for failed peroneal tendon dislocation surgery.

    Science.gov (United States)

    Gaulke, R; Hildebrand, F; Panzica, M; Hüfner, T; Krettek, C

    2010-04-01

    Recurrent dislocation of the peroneal tendons following operative treatment is relatively uncommon, but can be difficult to treat. We asked whether subligamental transposition of the peroneus brevis tendon, fibular grooving, and reattachment of the superior peroneal retinaculum for failed peroneal tendon dislocation surgery would achieve a stable fixation of the peroneal tendons and whether there would be restrictions of ROM or instability of the hindfoot. We reviewed six female patients (mean age, 24.5 years) with general laxity of joints preoperatively and at 6 weeks and 3, 6, and 12 months postoperatively. Within 1 year postoperatively no recurrence was found. In two ankles the extension was restricted 5 degrees to 10 degrees . In another pronation and supination was restricted 5 degrees each. Stability of the ankle increased in four patients and stayed unchanged in two. AOFAS score increased from a mean value of 36 +/- 20.6 preoperatively to 90 +/- 7 postoperatively at 1 year. We conclude transposition of the peroneus brevis tendon is a reasonable treatment for failed peroneal tendon dislocation surgery. Level IV, therapeutic study (prospective case series). See Guidelines for Authors for a complete description of levels of evidence.

  7. Glutaraldehyde cross-linking of tendon mechanical effects at the level of the tendon fascicle and fibril

    DEFF Research Database (Denmark)

    Hansen, Philip; Hassenkam, Tue; Svensson, Rene Bruggebusch

    2009-01-01

    at the tendon fibril level were examined by atomic force microscopy. Peak forces increased from approximately 1379 to approximately 2622 pN while an extended Hertz fit of force-indentation data showed a approximately 24 fold increase in Young's modulus on indentation. The effect of glutaraldehyde cross......Conclusive insight into the microscopic principles that govern the strength of tendon and related connective tissues is lacking and the importance of collagen cross-linking has not been firmly established. The combined application of whole-tissue mechanical testing and atomic force spectroscopy...... allowed for a detailed characterization of the effect of cross-linking in rat-tail tendon. The cross-link inducing agent glutaraldehyde augmented the tensile strength of tendon fascicles. Stress at failure increased from approximately 8 MPa to approximately 39 MPa. The mechanical effects of glutaraldehyde...

  8. Glutaraldehyde Cross-Linking of TendonMechanical Effects at the Level of the Tendon Fascicle and Fibril

    DEFF Research Database (Denmark)

    Hansen, P.; Svensson, R.B.; Aagaard, P.

    2009-01-01

    were examined by atomic force microscopy. Peak forces increased from 1379 to 2622 pN while an extended Hertz fit of force-indentation data showed a 24 fold increase in Young's modulus on indentation. The effect of glutaraldehyde cross-linking on the tensile properties of a single collagen fibril......Conclusive insight into the microscopic principles that govern the strength of tendon and related connective tissues is lacking and the importance of collagen cross-linking has not been firmly established. The combined application of whole-tissue mechanical testing and atomic force spectroscopy...... allowed for a detailed characterization of the effect of cross-linking in rat-tail tendon. The cross-link inducing agent glutaraldehyde augmented the tensile strength of tendon fascicles. Stress at failure increased from 8 MPa to 39 MPa. The mechanical effects of glutaraldehyde at the tendon fibril level...

  9. Vaginal reconstruction

    International Nuclear Information System (INIS)

    Lesavoy, M.A.

    1985-01-01

    Vaginal reconstruction can be an uncomplicated and straightforward procedure when attention to detail is maintained. The Abbe-McIndoe procedure of lining the neovaginal canal with split-thickness skin grafts has become standard. The use of the inflatable Heyer-Schulte vaginal stent provides comfort to the patient and ease to the surgeon in maintaining approximation of the skin graft. For large vaginal and perineal defects, myocutaneous flaps such as the gracilis island have been extremely useful for correction of radiation-damaged tissue of the perineum or for the reconstruction of large ablative defects. Minimal morbidity and scarring ensue because the donor site can be closed primarily. With all vaginal reconstruction, a compliant patient is a necessity. The patient must wear a vaginal obturator for a minimum of 3 to 6 months postoperatively and is encouraged to use intercourse as an excellent obturator. In general, vaginal reconstruction can be an extremely gratifying procedure for both the functional and emotional well-being of patients

  10. ACL Reconstruction

    Science.gov (United States)

    ... in moderate exercise and recreational activities, or play sports that put less stress on the knees. ACL reconstruction is generally recommended if: You're an athlete and want to continue in your sport, especially if the sport involves jumping, cutting or ...

  11. Tendinopathy of the long head of the biceps tendon: histopathologic analysis of the extra-articular biceps tendon and tenosynovium

    OpenAIRE

    Shishani, Yousef; Streit,Jonathan; Rodgers,Mark; Gobezie,Reuben

    2015-01-01

    Jonathan J Streit,1 Yousef Shishani,1 Mark Rodgers,2 Reuben Gobezie1 1The Cleveland Shoulder Institute, 2Department of Pathology, University Hospitals of Cleveland, Cleveland, OH, USA Background: Bicipital tendinitis is a common cause of anterior shoulder pain, but there is no evidence that acute inflammation of the extra-articular long head of the biceps (LHB) tendon is the root cause of this condition. We evaluated the histologic findings of the extra-articular portion of the LHB tendon an...

  12. The blood-tendon barrier: identification and characterisation of a novel tissue barrier in tendon blood vessels

    Directory of Open Access Journals (Sweden)

    C Lehner

    2016-05-01

    Full Text Available Tissue barriers function as “gate keepers” between different compartments (usually blood and tissue and are formed by specialised membrane-associated proteins, localising to the apicolateral plasma membrane domain of epithelial and endothelial cells. By sealing the paracellular space, the free diffusion of solutes and molecules across epithelia and endothelia is impeded. Thereby, tissue barriers contribute to the establishment and maintenance of a distinct internal and external environment, which is crucial during organ development and allows maintenance of an organ-specific homeostatic milieu. So far, various epithelial and endothelial tissue barriers have been described, including the blood-brain barrier, the blood-retina barrier, the blood-testis barrier, the blood-placenta barrier, and the cerebrospinal fluid (CSF-brain barrier, which are vital for physiological function and any disturbance of these barriers can result in severe organ damage or even death. Here, we describe the identification of a novel barrier, located in the vascular bed of tendons, which we term the blood-tendon barrier (BTB. By using immunohistochemistry, transmission electron microscopy, and tracer studies we demonstrate the presence of a functional endothelial barrier within tendons restricting the passage of large blood-borne molecules into the surrounding tendon tissue. We further provide in vitro evidence that the BTB potentially contributes to the creation of a distinct internal tissue environment impacting upon the proliferation and differentiation of tendon-resident cells, effects which might be fundamental for the onset of tendon pathologies.

  13. Regional strain variations in the human patellar tendon.

    Science.gov (United States)

    Pearson, Stephen J; Ritchings, Tim; Mohamed, Azlan S A

    2014-07-01

    Characteristics of localized tendon strain in vivo are largely unknown. The present study examines local tendon strain between the deep, middle, and surface structures at the proximal and distal aspects of the patellar tendon during ramped isometric contractions. Male subjects (age 28.0 ± 6.3 yr) were examined for patellar tendon excursion (anterior, midsection, and posterior) during ramped isometric voluntary contractions using real-time B-mode ultrasonography and dynamometry. Regional tendon excursion measurements were compared using an automated pixel tracking method. Strain was determined from the tendon delta length normalized to initial/resting segment length. Strain increased from 10% to 100% of force for all regions. Significantly greater mean strain was seen for the anterior proximal region compared to the posterior and mid layer of the tendon (7.5% ± 1.1% vs 3.7% ± 0.5% vs 5.5% ± 1.0%; P < 0.05). Similarly, the distal posterior region showed greater mean strain compared to the mid and anterior regions (7.9% ± 0.6% vs 5.0% ± 0.6% vs 5.4% ± 0.6%; P < 0.05). Relative changes in strain differences from 50% to 100% of force for the proximal region were greatest for the anterior to midline regions (4.6% ± 0.6% and 5.6% ± 0.6%, respectively) and those for the distal region were also greatest for the anterior to midline regions (4.4% ± 0.2% and 5.3% ± 0.2%, respectively). The largest mean strain for the proximal region was at the anterior layer (7.5% ± 1.1%) and that for the distal tendon region was at the posterior layer (7.9% ± 0.9%). This study shows significant regional differences in strain during ramped isometric contractions for the patellar tendon. Lower proximal strains in the posterior tendon compared to the anterior region may be associated with the suggestion of "stress shielding" as an etiological factor in insertional tendinopathy.

  14. Long bicipital tendon of the shoulder: normal anatomy and pathologic findings on MR imaging.

    Science.gov (United States)

    Erickson, S J; Fitzgerald, S W; Quinn, S F; Carrera, G F; Black, K P; Lawson, T L

    1992-05-01

    The tendon of the long head of the biceps muscle (long bicipital tendon) has a complex course from its muscle belly to its insertion onto the supraglenoid tubercle/glenoid labrum. It is stabilized by numerous tendinous and ligamentous structures and is, in turn, partly responsible for maintenance of normal glenohumeral function. In this report we describe the anatomy of this tendon, correlating high-resolution MR images with cryomicrotome sections. We illustrate typical MR findings in pathologic conditions affecting the long bicipital tendon sheath, the substance of the tendon, and finally the tendon position.

  15. Methods of Assessing Human Tendon Metabolism and Tissue Properties in Response to Changes in Mechanical Loading

    DEFF Research Database (Denmark)

    Heinemeier, Katja M; Kjaer, Michael; Magnusson, S Peter

    2016-01-01

    expression as well as protein synthesis rate. Further the (14)C bomb-pulse method has provided data on long-term tissue turnover in human tendon. Non-invasive techniques allow measurement of tendon metabolism (positron emission tomography (PET)), tendon morphology (magnetic resonance imaging (MRI......In recent years a number of methodological developments have improved the opportunities to study human tendon. Microdialysis enables sampling of interstitial fluid in the peritendon tissue, while sampling of human tendon biopsies allows direct analysis of tendon tissue for gene- and protein...

  16. Renal vessel reconstruction in kidney transplantation using a polytetrafluoroethylene (PTFE) vascular graft.

    Science.gov (United States)

    Kamel, Mohamed H; Thomas, Anil A; Mohan, Ponnusamy; Hickey, David P

    2007-04-01

    We report a rare experience in reconstructing short renal vessels in kidney transplantation using polytetrafluroethylene (PTFE) vascular grafts. The short renal vessels in three kidney grafts were managed by the interposition of PTFE vascular grafts. Two grafts were from deceased donors and the third was a renal auto-transplant graft. PTFE grafts were used to lengthen short renal veins in two kidney grafts and a short renal artery in one. The warm ischaemia time was under 1 h and all kidneys functioned well post-operatively. Excellent blood perfusion in the three renal grafts was present on postoperative MAG 3 renal scan. No intra-operative or post-operative complications were encountered. In the three described patients, the use of PTFE vascular graft presented no additional morbidity to the kidney transplant operation and no post-oerative complication was related to its use. However, more data are necessary to conclude that PTFE graft can be used safely in kidney transplantation.

  17. [Reconstruction of the heel in a two-year-old boy after lawn mower injury].

    Science.gov (United States)

    Kraus, R; Albrecht, J; Schnettler, R; von Pichler, M

    2012-04-01

    Lawn mower injuries in children usually involve the lower extremities and can lead to serious amputation injuries. Treatment should look not only at the acute reconstruction, but also on maintaining the ability to grow. We report the case of a two-year-old boy with amputation of the heel. The boy was run over by a lawn mower. He suffered a complete loss of heel soft tissue, 30 % of the os calcis and the Achilles tendon. The one-stage reconstruction was performed by transplantation of an iliac crest graft, fascia lata to reconstruct the Achilles tendon and a microvascular latissimus dorsi flap. After one year, the functional and cosmetic result is excellent, the bone graft is healed completely and shows growth trends. The successful treatment of such a severe amputation injury requires the interdisciplinary cooperation between paediatric traumatologists, plastic surgeons, physical therapists and orthopaedic shoemaker. The result justifies the great effort. © Georg Thieme Verlag KG Stuttgart · New York.

  18. A photoactivated nanofiber graft material for augmented Achilles tendon repair.

    Science.gov (United States)

    Ni, Tao; Senthil-Kumar, Prabhu; Dubbin, Karen; Aznar-Cervantes, Salvador D; Datta, Néha; Randolph, Mark A; Cenis, José L; Rutledge, Gregory C; Kochevar, Irene E; Redmond, Robert W

    2012-10-01

    Suture repair of Achilles tendon rupture can cause infection, inflammation and scarring, while prolonged immobilization promotes adhesions to surrounding tissues and joint stiffness. Early mobilization can reduce complications provided the repair is strong enough to resist re-rupture. We have developed a biocompatible, photoactivated tendon wrap from electrospun silk (ES) to provide additional strength to the repair that could permit early mobilization, and act as a barrier to adhesion formation. ES nanofiber mats were prepared by electrospinning. New Zealand white rabbits underwent surgical transection of the Achilles tendon and repair by: (a) SR: standard Kessler suture + epitendinous suture (5-0 vicryl). (b) ES/PTB: a single stay suture and a section of ES mat, stained with 0.1% Rose Bengal (RB), wrapped around the tendon and bonded with 532 nm light (0.3 W/cm(2) , 125 J/cm(2) ). (c) SR + ES/PTB: a combination of (a) and (b). Gross appearance, extent of adhesion formation and biomechanical properties of the repaired tendon were evaluated at Days 7, 14, or 28 post-operatively (n = 8 per group at each time point). Ultimate stress (US) and Young's modulus (E) in the SR group were not significantly different from the ES/PTB group at Days 7 (US, P = 0.85; E, P = 1), 14 (US, P = 0.054; E, P = 1), and 28 (US, P = 0.198; E, P = 0.12) post-operatively. Adhesions were considerably greater in the SR group compared to the ES/PTB group at Days 7 (P = 0.002), 14 (P tendon repair site provides considerable benefit in Achilles tendon repair. Lasers Surg. Med. 44: 645-652, 2012. © 2012 Wiley Periodicals, Inc. Copyright © 2012 Wiley Periodicals, Inc.

  19. Fixation of the Achilles tendon insertion using suture button technology.

    Science.gov (United States)

    Fanter, Nathan J; Davis, Edward W; Baker, Champ L

    2012-09-01

    In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Controlled laboratory study. The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.

  20. Achilles tendon and sports; Die Achillessehne im Sport

    Energy Technology Data Exchange (ETDEWEB)

    Ulreich, N.; Kainberger, F. [Univ.-Klinik fuer Radiodiagnostik Wien (Austria); Huber, W.; Nehrer, S. [Univ.-Klinik fuer Orthopaedie Wien (Austria)

    2002-10-01

    Because of the rising popularity of recreational sports activities achillodynia is an often associated symptom with running, soccer and athletics. Therefore radiologist are frequently asked to image this tendon. The origin of the damage of the Achilles tendon is explained by numerous hypothesis, mainly a decreased perfusion and a mechanical irritation that lead to degeneration of the tendon. High-resolution technics such as sonography and magnetic resonance imaging show alterations in the structure of the tendon which can be graduated and classified. Manifestations like tendinosis, achillobursitis, rupture and Haglunds disease can summarized as the tendon overuse syndrom. A rupture of a tendon is mostly the result of a degeneration of the collagenfibres. The task of the radiologist is to acquire the intrinsic factors for a potential rupture. (orig.) [German] Aufgrund des starken Anstiegs des Freizeitsportes sind Achillodynien ein besonders mit Laufsport, Fussball und Leichtathletik assoziiertes Symptom und die Indikation zur radiologischen Abklaerung wird oft gestellt. Die Entstehung von Sehnenschaeden wird durch eine Reihe von Hypothesen erklaert, wobei eine gestoerte Gewebeperfusion und eine mechanische Irritation als Hauptursachen angesehen werden, die zur Degeneration des Sehnengewebes und des umgebenden Gleitlagers fuehren. Sie koennen aufgrund sonographischer und MR-tomographischer Zeichen meist klar klassifiziert und graduiert werden, wobei hochaufloesende Techniken eine wesentliche Voraussetzung fuer die subtile Analyse der Sehnenstruktur darstellen. Die einzelnen klinischen Erscheinungsformen wie Tendinose, Achillobursitis, Haglund-Ferse und Sehnenruptur koennen unter dem Begriff des ''Sehnenueberlastungssyndroms'' (Tendon overuse syndrome) subsummiert werden. Rupturen der Achillessehne treten so gut wie immer bei bereits vorgeschaedigtem Kollagenfasergewebe auf, und der radiologischen Diagnostik kommt wesentliche Bedeutung dabei zu

  1. Effects of celecoxib on proliferation and tenocytic differentiation of tendon-derived stem cells

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Kairui; Zhang, Sheng [Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China); Li, Qianqian [Cancer Research Institute, Southern Medical University, Guangzhou 510515 (China); Yang, Jun [Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China); Department of Orthopaedics, 421 Hospital of PLA, Guangzhou 510318 (China); Dong, Weiqiang [Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China); Department of Orthopaedics, The First Affiliated Hospital to Guangzhou Medical University, Guangzhou 510120 (China); Wang, Shengnan; Cheng, Yirong; Al-Qwbani, Mohammed [Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China); Wang, Qiang, E-mail: 1780468505@qq.com [Department of Orthopaedics, Subei People’s Hospital of Jiangsu Province (Clinical Medical College of Yangzhou University), Yangzhou, Jiangsu Province 225001 (China); Yu, Bin, E-mail: carryzhang1985@live.com [Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China)

    2014-07-18

    Highlights: • Celecoxib has no effects on TDSCs cell proliferation in various concentrations. • Celecoxib reduced mRNAs levels of tendon associated transcription factor. • Celecoxib reduced mRNAs levels of main tendon associated collagen. • Celecoxib reduced mRNAs levels of tendon associated molecules. - Abstract: NSAIDs are often ingested to reduce the pain and improve regeneration of tendon after tendon injury. Although the effects of NSAIDs in tendon healing have been reported, the data and conclusions are not consistent. Recently, tendon-derived stem cells (TDSCs) have been isolated from tendon tissues and has been suggested involved in tendon repair. Our study aims to determine the effects of COX-2 inhibitor (celecoxib) on the proliferation and tenocytic differentiation of TDSCs. TDSCs were isolated from mice Achilles tendon and exposed to celecoxib. Cell proliferation rate was investigated at various concentrations (0.1, 1, 10 and 100 μg/ml) of celecoxib by using hemocytometer. The mRNA expression of tendon associated transcription factors, tendon associated collagens and tendon associated molecules were determined by reverse transcription-polymerase chain reaction. The protein expression of Collagen I, Collagen III, Scleraxis and Tenomodulin were determined by Western blotting. The results showed that celecoxib has no effects on TDSCs cell proliferation in various concentrations (p > 0.05). The levels of most tendon associated transcription factors, tendon associated collagens and tendon associated molecules genes expression were significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). Collagen I, Collagen III, Scleraxis and Tenomodulin protein expression were also significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). In conclusion, celecoxib inhibits tenocytic differentiation of tendon-derived stem cells but has no effects on cell proliferation.

  2. Effects of celecoxib on proliferation and tenocytic differentiation of tendon-derived stem cells

    International Nuclear Information System (INIS)

    Zhang, Kairui; Zhang, Sheng; Li, Qianqian; Yang, Jun; Dong, Weiqiang; Wang, Shengnan; Cheng, Yirong; Al-Qwbani, Mohammed; Wang, Qiang; Yu, Bin

    2014-01-01

    Highlights: • Celecoxib has no effects on TDSCs cell proliferation in various concentrations. • Celecoxib reduced mRNAs levels of tendon associated transcription factor. • Celecoxib reduced mRNAs levels of main tendon associated collagen. • Celecoxib reduced mRNAs levels of tendon associated molecules. - Abstract: NSAIDs are often ingested to reduce the pain and improve regeneration of tendon after tendon injury. Although the effects of NSAIDs in tendon healing have been reported, the data and conclusions are not consistent. Recently, tendon-derived stem cells (TDSCs) have been isolated from tendon tissues and has been suggested involved in tendon repair. Our study aims to determine the effects of COX-2 inhibitor (celecoxib) on the proliferation and tenocytic differentiation of TDSCs. TDSCs were isolated from mice Achilles tendon and exposed to celecoxib. Cell proliferation rate was investigated at various concentrations (0.1, 1, 10 and 100 μg/ml) of celecoxib by using hemocytometer. The mRNA expression of tendon associated transcription factors, tendon associated collagens and tendon associated molecules were determined by reverse transcription-polymerase chain reaction. The protein expression of Collagen I, Collagen III, Scleraxis and Tenomodulin were determined by Western blotting. The results showed that celecoxib has no effects on TDSCs cell proliferation in various concentrations (p > 0.05). The levels of most tendon associated transcription factors, tendon associated collagens and tendon associated molecules genes expression were significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). Collagen I, Collagen III, Scleraxis and Tenomodulin protein expression were also significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). In conclusion, celecoxib inhibits tenocytic differentiation of tendon-derived stem cells but has no effects on cell proliferation

  3. Comparative anatomy of rabbit and human achilles tendons with magnetic resonance and ultrasound imaging.

    Science.gov (United States)

    Doherty, Geoffrey P; Koike, Yoichi; Uhthoff, Hans K; Lecompte, Martin; Trudel, Guy

    2006-02-01

    We sought to describe the comparative anatomy of the Achilles tendon in rabbits and humans by using macroscopic observation, magnetic resonance imaging, and ultrasonography. The calcaneus-Achilles tendon-gastrocnemius-soleus complexes from 18 New Zealand white rabbits underwent ultrasound (US) and magnetic resonance (MR) imaging and gross anatomic sectioning; these results were compared with those from a cadaveric gastrocnemius-soleus-Achilles tendon-calcaneus specimen from a 68-y-old human male. The medial and lateral gastrocnemius muscle tendons merged 5.2 +/- 0.6 mm proximal to the calcaneal insertion macroscopically, at 93% of their course, different from the gastrocnemius human tendons, which merged at 23% of their overall course. The rabbit flexor digitorum superficialis tendon, corresponding to the flexor digitorum longus tendon in human and comparable in size with the gastrocnemius tendons, was located medial and anterior to the medial gastrocnemius tendon proximally and rotated dorsally and laterally to run posterior to the Achilles tendon-calcaneus insertion. In humans, the flexor digitorum longus tendon tracks posteriorly to the medial malleolus. The soleus muscle and tendon are negligible in the rabbit; these particular comparative anatomic features in the rabbit were confirmed on the MR images. Therefore the rabbit Achilles tendon shows distinctive gross anatomical and MR imaging features that must be considered when using the rabbit as a research model, especially for mechanical testing, or when generalizing results from rabbits to humans.

  4. Maxillary reconstruction

    Directory of Open Access Journals (Sweden)

    Brown James

    2007-12-01

    Full Text Available This article aims to discuss the various defects that occur with maxillectomy with a full review of the literature and discussion of the advantages and disadvantages of the various techniques described. Reconstruction of the maxilla can be relatively simple for the standard low maxillectomy that does not involve the orbital floor (Class 2. In this situation the structure of the face is less damaged and the there are multiple reconstructive options for the restoration of the maxilla and dental alveolus. If the maxillectomy includes the orbit (Class 4 then problems involving the eye (enopthalmos, orbital dystopia, ectropion and diplopia are avoided which simplifies the reconstruction. Most controversy is associated with the maxillectomy that involves the orbital floor and dental alveolus (Class 3. A case is made for the use of the iliac crest with internal oblique as an ideal option but there are other methods, which may provide a similar result. A multidisciplinary approach to these patients is emphasised which should include a prosthodontist with a special expertise for these defects.

  5. Biomechanical and histologic comparison of Achilles tendon ruptures reinforced with intratendinous and peritendinous plantaris tendon grafts in rabbits: an experimental study.

    Science.gov (United States)

    Ilhami, Kuru; Gokhan, Maralcan; Ulukan, Inan; Eray, Bozan M; Levent, Altinel; Ciğdem, Tokyol

    2004-11-01

    We hypothesized that the closer the reinforcing graft was to the repair zone, the more strength the healed tendon would achieved. Therefore, we compared the ruptured rabbit Achilles tendons reinforced with intratendinous and peritendinous plantaris grafts. The experimental study was performed on Achilles tendons of 20 rabbits. First, they were divided into two groups: group I (n=10) underwent intratendinous graft and end-to-end tenorraphy, and group P (n=10) were repaired end-to-end and then reinforced with a peritendinous plantaris graft. An above-knee cast was applied during 6 weeks postoperatively. The two groups were compared to each other biomechanically and histologically. Seven randomly selected rabbits from each group were used for biomechanical evaluation. The remaining six rabbits (three from each group) were used for histologic comparison. Non-operated sides (n=20) served as the control group. The mean maximum load at rupture of the repaired and control groups was 159.9+/-31 N, 83+/-7.5 N, and 207.5+/-35 N for group I, group P, and the control group, respectively. Values between groups were significantly different considering maximum load and absorbed energy to rupture. There was no significant difference between groups I and P in respect to strain. Control group tendons (groups I-C and P-C) had significantly more lengthening capability than operated tendons. Macroscopically, group I tendons were thicker and stiffer than group P tendons. Histologically, differences between the group I and group P specimens revealed that the healing process was faster in tendons augmented intratendinously. In reinforcing Achilles tendon repair, the site of the tendon graft affected the result. When the graft was used intratendinously, the healed tendon was more similar biomechanically to normal tendon and had more graft-tendon orientation histologically than the tendon augmented peritendinously.

  6. Effects of gamma irradiation on the biomechanical properties of peroneus tendons

    Directory of Open Access Journals (Sweden)

    Aguila CM

    2016-09-01

    Full Text Available Christopher M Aguila,1 Gaëtan J-R Delcroix,2–5 David N Kaimrajh,6 Edward L Milne,6 H Thomas Temple,5,7 Loren L Latta2,6 1Department of Biological Sciences, Florida International University, Miami, FL, USA; 2Department of Orthopaedics, Miller School of Medicine, University of Miami, Miami, FL, USA; 3Research Service & Geriatric Research, Education, and Clinical Center, Bruce W. Carter Veterans Affairs Medical Center, Miami, FL, USA; 4Interdisciplinary Stem Cell Institute, University of Miami, Miami, FL, USA; 5Vivex Biomedical Inc., Marietta, GA, USA; 6Max Biedermann Institute for Biomechanics, Miami Beach, FL, USA; 7Translational Research and Economic Development, Nova Southeastern University, Fort-Lauderdale, FL, USA Purpose: This study was designed to investigate the biomechanical properties of nonirradiated (NI and irradiated (IR peroneus tendons to determine if they would be suitable allografts, in regards to biomechanical properties, for anterior cruciate ligament reconstruction after a dose of 1.5–2.5 Mrad.Methods: Seven pairs of peroneus longus (PL and ten pairs of peroneus brevis (PB tendons were procured from human cadavers. The diameter of each allograft was measured. The left side of each allograft was IR at 1.5–2.5 Mrad, whereas the right side was kept aseptic and NI. The allografts were thawed, kept wet with saline, and attached in a single-strand fashion to custom freeze grips using liquid nitrogen. A preload of 10 N was then applied and, after it had reached steady state, the allografts were pulled at 4 cm/sec. The parameters recorded were the displacement and force.Results: The elongation at the peak load was 10.3±2.3 mm for the PB NI side and 13.5±3.3 mm for the PB IR side. The elongation at the peak load was 17.4±5.3 mm for the PL NI side and 16.3±2.0 mm for the PL IR side. For PL, the ultimate load was 2,091.6±148.7 N for NI and 2,122.8±380.0 N for IR. The ultimate load for the PB tendons was 1,485.7±209.3 N for

  7. MR imaging of delamination tears of the rotator cuff tendons

    International Nuclear Information System (INIS)

    Walz, Daniel M.; Chen, Steven; Miller, Theodore T.; Hofman, Josh

    2007-01-01

    The objective was to describe the imaging appearances and location of delamination tears of the rotator cuff tendons on non-contrast conventional MR imaging. This study was reviewed and approved by our Institutional Review Board. The reports of 548 consecutive MR examinations of the shoulder were reviewed, looking for mention or description of delamination tears of the rotator cuff. The images of the identified cases were then reviewed by two radiologists to confirm the findings. Correlation with surgical and arthroscopic information was then performed. Delamination tears were defined as horizontal retraction of either the bursal or articular surface of the tendon, manifest as thickening of the torn retracted edge, and/or interstitial splitting of the tendon, manifest as fluid-like high signal intensity on fat-suppressed T2-weighted oblique coronal images. Fourteen cases of delamination tears were identified in 13 patients. Ten of the cases involved the supraspinatus tendon, all with articular surface involvement. Nine of these supraspinatus cases were isolated tears and one occurred as part of a full thickness tear. All 10 of these supraspinatus cases showed medial retraction of the articular surface of the tendon, with thickening of the retracted edge, and 5 of the 10 had a demonstrable horizontal cleft in the interstitium. Four cases involved the subscapularis tendon, with articular surface disruption in three and pure interstitial delamination in one. Medial subluxation of the tendon of the long head of the biceps was present in all four cases. No delamination tears occurred on the bursal surface. Only three of the 14 shoulders underwent surgical repair with one confirmation of supraspinatus delamination, one confirmation of a subscapularis tear that had become a full thickness tear 10 months after initial imaging and another interstitial subscapularis delamination that was not identified arthroscopically. Delamination tears occur most often in the

  8. MR imaging of delamination tears of the rotator cuff tendons

    Energy Technology Data Exchange (ETDEWEB)

    Walz, Daniel M.; Chen, Steven [North Shore University Hospital, Department of Radiology, Manhasset, NY (United States); Miller, Theodore T. [Hospital for Special Surgery, Department of Radiology and Imaging, New York, NY (United States); Hofman, Josh [Long Island Jewish Medical Center, New Hyde Park, NY (United States)

    2007-05-15

    The objective was to describe the imaging appearances and location of delamination tears of the rotator cuff tendons on non-contrast conventional MR imaging. This study was reviewed and approved by our Institutional Review Board. The reports of 548 consecutive MR examinations of the shoulder were reviewed, looking for mention or description of delamination tears of the rotator cuff. The images of the identified cases were then reviewed by two radiologists to confirm the findings. Correlation with surgical and arthroscopic information was then performed. Delamination tears were defined as horizontal retraction of either the bursal or articular surface of the tendon, manifest as thickening of the torn retracted edge, and/or interstitial splitting of the tendon, manifest as fluid-like high signal intensity on fat-suppressed T2-weighted oblique coronal images. Fourteen cases of delamination tears were identified in 13 patients. Ten of the cases involved the supraspinatus tendon, all with articular surface involvement. Nine of these supraspinatus cases were isolated tears and one occurred as part of a full thickness tear. All 10 of these supraspinatus cases showed medial retraction of the articular surface of the tendon, with thickening of the retracted edge, and 5 of the 10 had a demonstrable horizontal cleft in the interstitium. Four cases involved the subscapularis tendon, with articular surface disruption in three and pure interstitial delamination in one. Medial subluxation of the tendon of the long head of the biceps was present in all four cases. No delamination tears occurred on the bursal surface. Only three of the 14 shoulders underwent surgical repair with one confirmation of supraspinatus delamination, one confirmation of a subscapularis tear that had become a full thickness tear 10 months after initial imaging and another interstitial subscapularis delamination that was not identified arthroscopically. Delamination tears occur most often in the

  9. Uncovering the cellular and molecular changes in tendon stem/progenitor cells attributed to tendon aging and degeneration.

    Science.gov (United States)

    Kohler, Julia; Popov, Cvetan; Klotz, Barbara; Alberton, Paolo; Prall, Wolf Christian; Haasters, Florian; Müller-Deubert, Sigrid; Ebert, Regina; Klein-Hitpass, Ludger; Jakob, Franz; Schieker, Matthias; Docheva, Denitsa

    2013-12-01

    Although the link between altered stem cell properties and tissue aging has been recognized, the molecular and cellular processes of tendon aging have not been elucidated. As tendons contain stem/progenitor cells (TSPC), we investigated whether the molecular and cellular attributes of TSPC alter during tendon aging and degeneration. Comparing TSPC derived from young/healthy (Y-TSPC) and aged/degenerated human Achilles tendon biopsies (A-TSPC), we observed that A-TSPC exhibit a profound self-renewal and clonogenic deficits, while their multipotency was still retained. Senescence analysis showed a premature entry into senescence of the A-TSPC, a finding accompanied by an upregulation of p16(INK4A). To identify age-related molecular factors, we performed microarray and gene ontology analyses. These analyses revealed an intriguing transcriptomal shift in A-TSPC, where the most differentially expressed probesets encode for genes regulating cell adhesion, migration, and actin cytoskeleton. Time-lapse analysis showed that A-TSPC exhibit decelerated motion and delayed wound closure concomitant to a higher actin stress fiber content and a slower turnover of actin filaments. Lastly, based on the expression analyses of microarray candidates, we suggest that dysregulated cell-matrix interactions and the ROCK kinase pathway might be key players in TSPC aging. Taken together, we propose that during tendon aging and degeneration, the TSPC pool is becoming exhausted in terms of size and functional fitness. Thus, our study provides the first fundamental basis for further exploration into the molecular mechanisms behind tendon aging and degeneration as well as for the selection of novel tendon-specific therapeutical targets. © 2013 The Authors. Aging Cell published by the Anatomical Society and John Wiley & Sons Ltd.

  10. The Waterfall Fascia Lata Interposition Arthroplasty “Grika Technique” as Treatment of Posttraumatic Osteoarthritis of the Elbow in a High-Demand Adult Patient: Validity and Reliability

    Directory of Open Access Journals (Sweden)

    Giuseppe Rollo

    2018-01-01

    Full Text Available Introduction. The elbow interposition arthroplasty is a very common procedure performed mainly on active young patients who need great functionality and for whom total joint replacement is contraindicated and arthrodesis is noncompliant. We are going to demonstrate a case of a 34-year-old male suffering from malunion of the distal humerus, elbow stiffness, and manifest signs of arthrosis of the dominant limb, treated with the IA Grika technique at a 5-year follow-up. Patients and Methods. The chosen criteria to evaluate the injured side and the uninjured side during the clinical and radiological follow-up were the objective function and related quality of life, measured by the Mayo Elbow Performance Score (MEPS, and postoperative complications. To assess flexion and supination forces and elbow muscular strength, a hydraulic dynamometer was used. Results. At a 5-year follow-up, the results were excellent as during the first year. Conclusions. The Grika technique is a valid and feasible option in the treatment of elbow injuries.

  11. A new barbed device for repair of flexor tendons.

    LENUS (Irish Health Repository)

    Hirpara, K M

    2012-02-01

    We split 100 porcine flexor tendons into five groups of 20 tendons for repair. Three groups were repaired using the Pennington modified Kessler technique, the cruciate or the Savage technique, one using one new device per tendon and the other with two new devices per tendon. Half of the tendons received supplemental circumferential Silfverskiold type B cross-stitch. The repairs were loaded to failure and a record made of their bulk, the force required to produce a 3 mm gap, the maximum force applied before failure and the stiffness. When only one device was used repairs were equivalent to the Pennington modified Kessler for all parameters except the force to produce a 3 mm gap when supplemented with a circumferential repair, which was equivalent to the cruciate. When two devices were used the repair strength was equivalent to the cruciate repair, and when the two-device repair was supplemented with a circumferential suture the force to produce a 3 mm gap was equivalent to that of the Savage six-strand technique.

  12. Anti-inflammatory management for tendon injuries - friends or foes?

    Directory of Open Access Journals (Sweden)

    Chan Kai-Ming

    2009-10-01

    Full Text Available Abstract Acute and chronic tendon injuries are very common among athletes and in sedentary population. Most physicians prescribe anti-inflammatory managements to relieve the worst symptoms of swelling and pain, including non-steroidal anti-inflammatory drugs, corticosteroids and physical therapies. However, experimental research shows that pro-inflammatory mediators such as prostaglandins may play important regulatory roles in tendon healing. Noticeably nearly all cases of chronic tendon injuries we treat as specialists have received non-steroidal anti-inflammatory drugs by their physician, suggesting that there might be a potential interaction in some of these cases turning a mild inflammatory tendon injury into chronic tendinopathy in predisposed individuals. We are aware of the fact that non-steroidal anti-inflammatory drugs and corticosteroids may well have a positive effect on the pain control in the clinical situation whilst negatively affect the structural healing. It follows that a comprehensive evaluation of anti-inflammatory management for tendon injuries is needed and any such data would have profound clinical and health economic importance.

  13. Changes in tendon spatial frequency parameters with loading.

    Science.gov (United States)

    Pearson, Stephen J; Engel, Aaron J; Bashford, Gregory R

    2017-05-24

    To examine and compare the loading related changes in micro-morphology of the patellar tendon. Fifteen healthy young males (age 19±3yrs, body mass 83±5kg) were utilised in a within subjects matched pairs design. B mode ultrasound images were taken in the sagittal plane of the patellar tendon at rest with the knee at 90° flexion. Repeat images were taken whilst the subjects were carrying out maximal voluntary isometric contractions. Spatial frequency parameters related to the tendon morphology were determined within regions of interest (ROI) from the B mode images at rest and during isometric contractions. A number of spatial parameters were observed to be significantly different between resting and contracted images (Peak spatial frequency radius (PSFR), axis ratio, spatial Q-factor, PSFR amplitude ratio, and the sum). These spatial frequency parameters were indicative of acute alterations in the tendon micro-morphology with loading. Acute loading modifies the micro-morphology of the tendon, as observed via spatial frequency analysis. Further research is warranted to explore its utility with regard to different loading induced micro-morphological alterations, as these could give valuable insight not only to aid strengthening of this tissue but also optimization of recovery from injury and treatment of conditions such as tendinopathies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Nonlinear model for viscoelastic behavior of Achilles tendon.

    Science.gov (United States)

    Kahn, Cyril J F; Wang, Xiong; Rahouadj, Rachid

    2010-11-01

    Although the mechanical properties of ligament and tendon are well documented in research literature, very few unified mechanical formulations can describe a wide range of different loadings. The aim of this study was to propose a new model, which can describe tendon responses to various solicitations such as cycles of loading, unloading, and reloading or successive relaxations at different strain levels. In this work, experiments with cycles of loading and reloading at increasing strain level and sequences of relaxation were performed on white New Zealand rabbit Achilles tendons. We presented a local formulation of thermodynamic evolution outside equilibrium at a representative element volume scale to describe the tendon's macroscopic behavior based on the notion of relaxed stress. It was shown that the model corresponds quite well to the experimental data. This work concludes with the complexity of tendons' mechanical properties due to various microphysical mechanisms of deformation involved in loading such as the recruitment of collagen fibers, the rearrangement of the microstructure (i.e., collagens type I and III, proteoglycans, and water), and the evolution of relaxed stress linked to these mechanisms.

  15. Button fixation technique for Achilles tendon reinsertion: a biomechanical study.

    Science.gov (United States)

    Awogni, David; Chauvette, Guillaume; Lemieux, Marie-Line; Balg, Frédéric; Langelier, Ève; Allard, Jean-Pascal

    2014-01-01

    Chronic insertional tendinopathy of the Achilles tendon is a frequent and disabling pathologic entity. Operative treatment is indicated for patients for whom nonoperative management has failed. The treatment can consist of the complete detachment of the tendon insertion and extensive debridement. We biomechanically tested a new operative technique that uses buttons for fixation of the Achilles tendon insertion on the posterior calcaneal tuberosity and compared it with 2 standard bone anchor techniques. A total of 40 fresh-frozen cadaver specimens were used to compare 3 fixation techniques for reinserting the Achilles tendon: single row anchors, double row anchors, and buttons. The ultimate loads and failure mechanisms were recorded. The button assembly (median load 764 N, range 713 to 888) yielded a median fixation strength equal to 202% (range 137% to 251%) of that obtained with the double row anchors (median load 412 N, range 301 to 571) and 255% (range 213% to 317%) of that obtained with the single row anchors (median load 338 N, range 241 to 433N). The most common failure mechanisms were suture breakage with the buttons (55%) and pull out of the implant with the double row (70%) and single row (85%) anchors. The results of the present biomechanical cadaver study have shown that Achilles tendon reinsertion fixation using the button technique provides superior pull out strength than the bone anchors tested. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  16. An investigation of tendon sheathing filler migration into concrete

    International Nuclear Information System (INIS)

    Naus, D.J.; Oland, C.B.

    1998-03-01

    During some of the inspections at nuclear power plants with prestressed concrete containments, it was observed that the containments has experienced leakage of the tendon sheathing filler (i.e., streaks). The objective of this activity was to provide an indication of the extent of tendon sheathing filler leakage into the concrete and its affects on concrete properties. Literature was reviewed and concrete core samples were obtained from the Trojan Nuclear Plant and tested. The literature primarily addressed effects of crude or lubricating oils that are known to cause concrete damage. However, these materials have significantly different characteristics relative to the materials used as tendon sheathing fillers. Examination and testing of the concrete cores indicated that the appearance of tendon sheathing filler on the concrete surface was due to leakage from the conduits and its subsequent migration through cracks that were present. Migration of the tendon sheathing filler was confined to the cracks and there was no perceptible movement into the concrete. Results of compressive strength testing indicated that the concrete quality was consistent in the containment and that the strength had increased over 40% in 25.4 years relative to the average compressive strength at 28-days age

  17. Effect of aging and exercise on the tendon

    DEFF Research Database (Denmark)

    Svensson, Rene B; Heinemeier, Katja Maria; Couppé, Christian

    2016-01-01

    Here, we review the literature on how tendons respond and adapt to ageing and exercise. With respect to aging, there are considerable changes early in life, but this seems to be maturation rather than aging per se. In vitro data indicate that aging is associated with a decreased potential for cel...... and modulus of the tendon and may reduce the amount of glycation. Exercise thereby tends to counteract the effects of aging.......Here, we review the literature on how tendons respond and adapt to ageing and exercise. With respect to aging, there are considerable changes early in life, but this seems to be maturation rather than aging per se. In vitro data indicate that aging is associated with a decreased potential for cell...... glycation-derived cross-links increase substantially. Mechanically, aging appears to be associated with a reduction in modulus and strength. With respect to exercise, tendon cells respond by producing growth factors, and there is some support for a loading-induced increase in tendon collagen synthesis...

  18. Effects of aging and resistance training in rat tendon remodeling.

    Science.gov (United States)

    Marqueti, Rita C; Durigan, João L Q; Oliveira, Anderson José S; Mekaro, Marcelo Shinyu; Guzzoni, Vinicius; Aro, Andrea A; Pimentel, Edson Rosa; Selistre-de-Araujo, Heloisa S

    2018-01-01

    In elderly persons, weak tendons contribute to functional limitations, injuries, and disability, but resistance training can attenuate this age-related decline. We evaluated the effects of resistance training on the extracellular matrix (ECM) of the calcaneal tendon (CT) in young and old rats and its effect on tendon remodeling. Wistar rats aged 3 mo (young, n = 30) and 20 mo (old, n = 30) were divided into 4 groups: young sedentary, young trained, old sedentary (OS), and old trained (OT). The training sessions were conducted over a 12-wk period. Aging in sedentary rats showed down-regulation in key genes that regulated ECM remodeling. Moreover, the OS group showed a calcification focus in the distal region of the CT, with reduced blood vessel volume density. In contrast, resistance training was effective in up-regulating connective tissue growth factor, VEGF, and decorin gene expression in old rats. Resistance training also increased proteoglycan content in young and old rats in special small leucine-rich proteoglycans and blood vessels and prevented calcification in OT rats. These findings confirm that resistance training is a potential mechanism in the prevention of aging-related loss in ECM and that it attenuates the detrimental effects of aging in tendons, such as ruptures and tendinopathies.-Marqueti, R. C., Durigan, J. L. Q., Oliveira, A. J. S., Mekaro, M. S., Guzzoni, V., Aro, A. A., Pimentel, E. R., Selistre-de-Araujo, H. S. Effects of aging and resistance training in rat tendon remodeling. © FASEB.

  19. Genetics Home Reference: hereditary fibrosing poikiloderma with tendon contractures, myopathy, and pulmonary fibrosis

    Science.gov (United States)

    ... Hereditary fibrosing poikiloderma with tendon contractures, myopathy, and pulmonary fibrosis Printable PDF Open All Close All Enable Javascript ... Fibrosing Poikiloderma with Tendon Contractures, Myopathy, and Pulmonary ... Lung, and Blood Institute (NHLBI): Pulmonary Function Tests National ...

  20. The adaptability of tendon to loading differs in men and women

    DEFF Research Database (Denmark)

    Magnusson, Peter S; Hansen, Philip; Langberg, Henning

    2007-01-01

    The reason why women sustain more soft tissue injury than men during physical activity is unknown. Connective tissue properties and extracellular matrix adaptability in human tendon were investigated in models that addressed biochemical, physiological and biomechanical aspects of tendon connectiv...

  1. Diclofenac Patch for Treatment of Mild to Moderate Tendonitis or Bursitis

    Science.gov (United States)

    2008-08-05

    Rotator Cuff Tendonitis; Bicipital Tendonitis; Subdeltoid Bursitis of the Shoulder; Subacromial Bursitis of the Shoulder; Medial Epicondylitis of the Elbow; Lateral Epicondylitis of the Elbow; DeQuervain's Tenosynovitis of the Wrist

  2. MOLECULAR PATHOBIOLOGICAL AND SCANNING ELECTRON MICROSCOPIC CHANGES IN HORSE TENDON CELLS TREA TED WITH ENROFLOXACIN

    Directory of Open Access Journals (Sweden)

    A. Khan1 and J. Halper

    2003-12-01

    Full Text Available Fluoroquinolone (FQNL antibiotics have been used widely in horses because of their broad-spectrum bactericidal activity and relative safety, however, their use is not without risk. Tendonitis and spontaneous tendon rupture have been reported in people during or following therapy with FQNLs. To evaluate the potential damage of enrofloxacin (ENRO on the equine superficial digital flexor tendon (SOFT, an equine cell culture system as an in vitro model of equine tendon injury and repair was developed. The effects of ENRO on tendon cell cultures established from equine SOFT were studied. The data thus collected demonstrated that ENRO inhibited cell proliferation, induced morphological changes and altered proteoglycan synthesis in equine tendon cell cultures. Interestingly, these effects were more pronounced in juvenile tendon cells as compared to adult horses, It. is hypothesized that morphological changes and inhibition of cell proliferation is a result of impaired production of proteoglycans and other glycoproteins in the extracellular matrix of ENRO-treated tendon cells.

  3. Editorial Commentary: All-Inside Anterior Cruciate Ligament Reconstruction Can Afford Satisfactory Clinical Outcome and Functional Stability.

    Science.gov (United States)

    Yoshiya, Shinichi

    2016-02-01

    Anatomic all-inside anterior cruciate ligament reconstruction using the autogenous semitendinosus tendon graft can afford satisfactory outcomes, achieving significant postoperative improvement in all clinical parameters. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  4. Revision with suture-tape augmentation after failed collateral ligament reconstruction for chronic interphalangeal instability of the hallux.

    Science.gov (United States)

    Cho, Byung-Ki; Park, Ji-Kang; Choi, Seung-Myung; SooHoo, Nelson F

    2017-12-01

    Chronic varus instability or recurrent subluxation following isolated interphalangeal dislocation of the hallux is a rare injury. No consensus has been reached regarding the best joint-salvage procedure for patients with the failed collateral ligament reconstruction using tendon graft. We report a case who achieved satisfactory clinical outcome through a modified surgical procedure (revision collateral ligament reconstruction augmented with suture-tape). Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  5. MRI of the Achilles tendon: A comprehensive review of the anatomy, biomechanics, and imaging of overuse tendinopathies

    Energy Technology Data Exchange (ETDEWEB)

    Pierre-Jerome, Claude; Moncayo, Valeria; Terk, Michael R. (Dept. of Radiology, Emory Univ. Orthopedics and Spine Center, Atlanta, GA (United States)), e-mail: cpierr3@emory.edu

    2010-05-15

    The Achilles tendon is the largest tendon in the body; it plays an important role in the biomechanics of the lower extremity. It can withstand great forces, especially during sporting exercises and pivoting. The pathologies related to the Achilles tendon are diverse and many carry undesirable consequences. We retrospectively analyzed the images of patients who underwent examinations of the ankle/foot region to review the anatomy of the Achilles tendon and its surroundings and to search for pathologies consistent with overuse injuries. The anatomy of the tendon is described from origin to insertion. The imaging characteristics of the Achilles tendon including pitfalls are reviewed. We also describe the Achilles overuse injuries: paratenonitis, tendinosis, tendon tear, atypical tear, tendon re-tear, retrocalcaneal bursitis, retro-Achilles bursitis, Haglund's deformity, and tendon calcification. We present other entities like tendon ossification and failed transplanted Achilles tendon, with emphasis on MRI

  6. MRI of the Achilles tendon: A comprehensive review of the anatomy, biomechanics, and imaging of overuse tendinopathies

    International Nuclear Information System (INIS)

    Pierre-Jerome, Claude; Moncayo, Valeria; Terk, Michael R.

    2010-01-01

    The Achilles tendon is the largest tendon in the body; it plays an important role in the biomechanics of the lower extremity. It can withstand great forces, especially during sporting exercises and pivoting. The pathologies related to the Achilles tendon are diverse and many carry undesirable consequences. We retrospectively analyzed the images of patients who underwent examinations of the ankle/foot region to review the anatomy of the Achilles tendon and its surroundings and to search for pathologies consistent with overuse injuries. The anatomy of the tendon is described from origin to insertion. The imaging characteristics of the Achilles tendon including pitfalls are reviewed. We also describe the Achilles overuse injuries: paratenonitis, tendinosis, tendon tear, atypical tear, tendon re-tear, retrocalcaneal bursitis, retro-Achilles bursitis, Haglund's deformity, and tendon calcification. We present other entities like tendon ossification and failed transplanted Achilles tendon, with emphasis on MRI

  7. Tendinopathy of the long head of the biceps tendon: histopathologic analysis of the extra-articular biceps tendon and tenosynovium.

    Science.gov (United States)

    Streit, Jonathan J; Shishani, Yousef; Rodgers, Mark; Gobezie, Reuben

    2015-01-01

    Bicipital tendinitis is a common cause of anterior shoulder pain, but there is no evidence that acute inflammation of the extra-articular long head of the biceps (LHB) tendon is the root cause of this condition. We evaluated the histologic findings of the extra-articular portion of the LHB tendon and synovial sheath in order to compare those findings to known histologic changes seen in other tendinopathies. Twenty-six consecutive patients (mean age 45.4±13.7 years) underwent an open subpectoral biceps tenodesis for anterior shoulder pain localized to the bicipital groove. Excised tendons were sent for histologic analysis. Specimens were graded using a semiquantitative scoring system to evaluate tenocyte morphology, the presence of ground substance, collagen bundle characteristics, and vascular changes. Chronic inflammation was noted in only two of 26 specimens, and no specimen demonstrated acute inflammation. Tenocyte enlargement and proliferation, characterized by increased roundness and size of the cell and nucleus with proteoglycan matrix expansion and myxoid degenerative changes, was found in all 26 specimens. Abundant ground substance, collagen bundle changes, and increased vascularization were visualized in all samples. Anterior shoulder pain attributed to the biceps tendon does not appear to be due to an inflammatory process in most cases. The histologic findings of the extra-articular portion of the LHB tendon and synovial sheath are similar to the pathologic findings in de Quervain tenosynovitis at the wrist, and may be due to a chronic degenerative process similar to this and other tendinopathies of the body.

  8. Ultrasound elasticity imaging of human posterior tibial tendon

    Science.gov (United States)

    Gao, Liang

    Posterior tibial tendon dysfunction (PTTD) is a common degenerative condition leading to a severe impairment of gait. There is currently no effective method to determine whether a patient with advanced PTTD would benefit from several months of bracing and physical therapy or ultimately require surgery. Tendon degeneration is closely associated with irreversible degradation of its collagen structure, leading to changes to its mechanical properties. If these properties could be monitored in vivo, it could be used to quantify the severity of tendonosis and help determine the appropriate treatment. Ultrasound elasticity imaging (UEI) is a real-time, noninvasive technique to objectively measure mechanical properties in soft tissue. It consists of acquiring a sequence of ultrasound frames and applying speckle tracking to estimate displacement and strain at each pixel. The goals of my dissertation were to 1) use acoustic simulations to investigate the performance of UEI during tendon deformation with different geometries; 2) develop and validate UEI as a potentially noninvasive technique for quantifying tendon mechanical properties in human cadaver experiments; 3) design a platform for UEI to measure mechanical properties of the PTT in vivo and determine whether there are detectable and quantifiable differences between healthy and diseased tendons. First, ultrasound simulations of tendon deformation were performed using an acoustic modeling program. The effects of different tendon geometries (cylinder and curved cylinder) on the performance of UEI were investigated. Modeling results indicated that UEI accurately estimated the strain in the cylinder geometry, but underestimated in the curved cylinder. The simulation also predicted that the out-of-the-plane motion of the PTT would cause a non-uniform strain pattern within incompressible homogeneous isotropic material. However, to average within a small region of interest determined by principal component analysis (PCA

  9. Mechanical anchorage of FRP tendons – A literature review

    DEFF Research Database (Denmark)

    Schmidt, Jacob W.; Bennitz, Anders; Täljsten, Björn

    2012-01-01

    High tensile strength, good resistance to degradation and creep, low weight and, to some extent, the ability to change the modulus of elasticity are some of the advantages of using prestressed, unidirectional FRP (Fibre Reinforced Polymer) tendon systems. Bonded and non-bonded versions of these s......High tensile strength, good resistance to degradation and creep, low weight and, to some extent, the ability to change the modulus of elasticity are some of the advantages of using prestressed, unidirectional FRP (Fibre Reinforced Polymer) tendon systems. Bonded and non-bonded versions...... with such systems. This is especially important in external post-tensioned tendon systems, where the anchorage points are exposed to the full load throughout the life span of the structure. Consequently, there are large requirements related to the long-term capacity and fatigue resistance of such systems. Several...

  10. Validity and Reliability of the Achilles Tendon Total Rupture Score

    DEFF Research Database (Denmark)

    Ganestam, Ann; Barfod, Kristoffer; Klit, Jakob

    2013-01-01

    study was to validate a Danish translation of the ATRS. The ATRS was translated into Danish according to internationally adopted standards. Of 142 patients, 90 with previous rupture of the Achilles tendon participated in the validity study and 52 in the reliability study. The ATRS showed moderately......The best treatment of acute Achilles tendon rupture remains debated. Patient-reported outcome measures have become cornerstones in treatment evaluations. The Achilles tendon total rupture score (ATRS) has been developed for this purpose but requires additional validation. The purpose of the present...... = .07). The limits of agreement were ±18.53. A strong correlation was found between test and retest (intercorrelation coefficient .908); the standard error of measurement was 6.7, and the minimal detectable change was 18.5. The Danish version of the ATRS showed moderately strong criterion validity...

  11. Could Ossification of the Achilles Tendon Have a Hereditary Component?

    Directory of Open Access Journals (Sweden)

    Chawki Cortbaoui

    2013-01-01

    Full Text Available Ossification of the Achilles tendon (OTA is an unusual clinical condition. It is characterized by the presence of an ossified mass within the fibrocartilaginous substance of the Achilles tendon. The etiology of the ossification of the Achilles tendon is unknown. Review of the literature suggests that its etiology is multifactorial. The major contributing factors are trauma and surgery with other minor causes such as systemic diseases, metabolic conditions, and infections. To our knowledge, no previous reports suggest any genetic/hereditary predisposition in OAT. We report 3 siblings who have OAT with no history of any of the aforementioned predisposing factors. Could OAT have a hereditary component as one of its etiologies?

  12. PRP as an Adjunct to Rotator Cuff Tendon Repair.

    Science.gov (United States)

    Barber, F Alan

    2018-06-01

    Arthroscopic rotator cuff repair is a commonly performed repair. Technical developments provide surgeons the tools to create biomechanically robust repairs. How can the biological response mirror the strong and stable surgery? Platelet-rich plasma (PRP) is a supraphysiological platelet concentration which may positively augment rotator cuff healing. Not all PRPs are the same. High leukocyte levels and thrombin activation may be detrimental to tendon healing. Thrombin activation triggers an immediate release of growth factors and may actually inhibit some parts of the healing response. Clear differences exist between liquid PRP (products released within hours after activation) and solid fibrin PRP which slowly releases factors over days. The heterogenicity data and grouping liquid and solid PRP together make systematic reviews confusing. Solid PRP fibrin constructs are often associated with increased tendon healing. PRP fibrin matrix offers the greatest promise for improving clinical success after rotator cuff tendon repair.

  13. Biomechanical characteristics of the eccentric Achilles tendon exercise

    DEFF Research Database (Denmark)

    Henriksen, Marius; Aaboe, Jens; Bliddal, Henning

    2009-01-01

    that although the tendon loads are similar, the tendon is vibrated at higher frequencies during the eccentric phase than during the concentric phases. This study provides data that may explain the mechanisms behind the effectiveness of eccentric exercises used in the treatment of Achilles tendinopathies........ No differences in Achilles tendon loads were found. INTERPRETATION: This descriptive study demonstrates differences in the movement biomechanics between the eccentric and concentric phases of one-legged full weight bearing ankle dorsal and plantar flexion exercises. In particular, the findings imply......BACKGROUND: Eccentric exercise has been shown to provide good short-term clinical results in the treatment of painful mid-portion chronic Achilles tendinopathies. However, the mechanisms behind the positive effects of eccentric rehabilitation regimes are not known, and research...

  14. Surgical treatment of distal biceps tendon rupture: a case report

    Directory of Open Access Journals (Sweden)

    Cristina N. Cozma

    2017-11-01

    Full Text Available Objectives. Distal biceps tendon rupture affects the functional upperextremity movement, impairing supination and flexion strength. According to age, profession and additional risks treatment might be nonoperative or surgical. Methods. We describe the case of a 43 years old male patient who sustained an injury to his right distal biceps and was diagnosed with acute right distal biceps rupture. Surgical treatment was decided and biceps tendon was reinserted to the radius tuberosity using a combination of a cortical button fixation associated with an interference screw. Results. Postoperative functional result was favorable with no complications and with no movement limitation after one month. Conclusions. When possible, distal biceps tendon repair should be realized surgically because this permits restoring of the muscle strength to near normal levels with no loss of motion. Nerve complications are common; therefore the surgery should be realized by experienced upper extremity surgeons.

  15. Multiple Tophaceous Gout of Hand with Extensor Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Haruki Tobimatsu

    2017-01-01

    Full Text Available A 45-year-old man presented with painless subcutaneous masses bilaterally on his hands and loss of motion or contracture of the fingers. Initially, drug therapy to reduce the serum uric acid was administered and was expected to reduce the tophi. However, during observation at the clinic, spontaneous rupture of an extensor tendon occurred, and surgical repair of the tendon and resection of the masses were performed. Surgical exploration of the right hand showed hypertrophic white-colored crystal deposits that both surrounded and invaded the extensor digitorum communis of the index finger, which was ruptured. Histopathologic examination of the specimen demonstrated findings consistent with gouty tophi. Tophaceous gout can induce a rupture of tendons during clinical observation, and surgical resection of the tophi might be needed to prevent ruptures.

  16. Morpho-functional changes in human tendon tissue

    Directory of Open Access Journals (Sweden)

    I Galliani

    2009-12-01

    Full Text Available Insertion tissue biopsies of right arm common extensor tendons from 11 patients with chronic lateral epicondylitis were processed for light and electron microscopy. The subjects were aged between 38 and 54 years (only one was 25. The specimens showed a variety of structural changes such as biochemical and spatial alteration of collagen, hyaline degeneration, loss of tenocytes, fibrocartilage metaplasia, calcifying processes, neovascularization and vessel wall modifications. Tissue alterations were evident in limited zones of the tendon fibrocartilage in which the surgical resection was generally visible. The areas where the degenerative processes were localized, were restricted and in spatial contiguity with morphologically normal ones. The observed cases presented histological and electron microscopic findings that characterize lateral epicondylitis as a degenerative phenomenon involving all tendon components.

  17. Metabolic activity and collagen turnover in human tendon in response to physical activity

    DEFF Research Database (Denmark)

    Kjaer, M; Langberg, H; Miller, B F

    2005-01-01

    Connective tissue of the human tendon plays an important role in force transmission. The extracellular matrix turnover of tendon is influenced by physical activity. Blood flow, oxygen demand, and the level of collagen synthesis and matrix metalloproteinases increase with mechanical loading. Gene...... of overuse tendon injuries occurring during sport, work or leisure-related activities....

  18. Increased mast cell numbers in a calcaneal tendon overuse model.

    Science.gov (United States)

    Pingel, J; Wienecke, J; Kongsgaard, M; Behzad, H; Abraham, T; Langberg, H; Scott, A

    2013-12-01

    Tendinopathy is often discovered late because the initial development of tendon pathology is asymptomatic. The aim of this study was to examine the potential role of mast cell involvement in early tendinopathy using a high-intensity uphill running (HIUR) exercise model. Twenty-four male Wistar rats were divided in two groups: running group (n = 12); sedentary control group (n = 12). The running-group was exposed to the HIUR exercise protocol for 7 weeks. The calcaneal tendons of both hind limbs were dissected. The right tendon was used for histologic analysis using Bonar score, immunohistochemistry, and second harmonic generation microscopy (SHGM). The left tendon was used for quantitative polymerase chain reaction (qPCR) analysis. An increased tendon cell density in the runners were observed compared to the controls (P = 0.05). Further, the intensity of immunostaining of protein kinase B, P = 0.03; 2.75 ± 0.54 vs 1.17 ± 0.53, was increased in the runners. The Bonar score (P = 0.05), and the number of mast cells (P = 0.02) were significantly higher in the runners compared to the controls. Furthermore, SHGM showed focal collagen disorganization in the runners, and reduced collagen density (P = 0.03). IL-3 mRNA levels were correlated with mast cell number in sedentary animals. The qPCR analysis showed no significant differences between the groups in the other analyzed targets. The current study demonstrates that 7-week HIUR causes structural changes in the calcaneal tendon, and further that these changes are associated with an increased mast cell density. © 2013 The Authors. Scand J Med Sci Sports published by John Wiley & Sons Ltd.

  19. Treatment with vacuum-assisted closure and cryo-preserved homologous de-epidermalised dermis of complex traumas to the lower limbs with loss of substance, and bones and tendons exposure.

    Science.gov (United States)

    Brandi, C; Grimaldi, L; Nisi, G; Silvestri, A; Brafa, A; Calabrò, M; D'Aniello, C

    2008-12-01

    Lower-limb injuries with loss of tissue and exposure of bones and tendons are an increasing problem. The condition of the wound locally and the patient in general does not always allow immediate and adequate coverage of the structures exposed by the trauma. Therefore, new therapeutic solutions are needed. A reduction in the time that bones and tendons are exposed is essential to achieve complete healing of bone fractures, with reduced risks of infection and less disabling outcomes. The effectiveness of vacuum-assisted closure (VAC) therapy in supporting wound healing and of cryopreserved homologous de-epidermalised dermis (DED) in providing an effective template for re-epithelialisation has been previously reported. We carried out a study to evaluate the effectiveness of the synergistic and combined use of the two methodologies. Eighteen patients with traumatic loss of tissue in the lower limbs, involving exposure of bone and tendon structures, were enrolled in the study. All participants had local, general contraindications to first-instance reconstructions, or both. All patients received a combination of VAC therapy and DED implants. Granulation tissue was obtained in all wounds, with complete coverage of exposed structures. No infections were detected in the cohort, and all patients were prepared for further necessary reconstructive treatments. In our experience, the combination of VAC therapy and DED could, in selected cases, constitute an effective treatment for complex lower limb traumatic injuries with bone and tendon exposure.

  20. Repair of the radiation induced rectovaginal fistulas without or with interposition of the bulbocavernosus muscle (Martius procedure)

    Energy Technology Data Exchange (ETDEWEB)

    Aartsen, E.J.; Sindram, I.S.

    1988-04-01

    Two local repair procedures, one without (9) and the other with (14) a bulbocavernosus muscle graft were performed on 20 patients with a radiation induced rectovaginal fistula. Four patients had two procedures successively. The initial success rate of both procedures was 7/9 and 14/14 respectively. Though the initial result of the bulbocavernosus graft was obviously better, in many of the local repair procedures, subclinical radiation damage progressed, resulting in recurrence of rectovaginal fistula (5), rectovesical fistula (4), pararectal abscess (2) etc. After a mean follow up of around 10 years, the success rate of fistula repair decreased to 5/9 and 13/14 and only 2/9 and 6/14 finally remained without a colostomy. A local repair operation should be restricted to carefully selected cases. The musculus gracilis is proposed as a better vascular graft. If the general condition of the patient does not allow more aggressive reconstructive procedures, fistula repair is better cancelled because there is a high risk of subsequent radiation damage.

  1. Supraspinatus Intramuscular Calcified Hematoma or Necrosis Associated with Tendon Tear

    Directory of Open Access Journals (Sweden)

    Alexandre Lädermann

    2015-01-01

    Full Text Available Introduction. Rotator cuff intramuscular calcification is a rare condition usually caused by heterotopic ossification and myositis ossificans. Case Presentation. We describe a patient with voluminous calcified mass entrapped in supraspinatus muscle associated with corresponding tendon tear. Histological examination corresponded to a calcified hematoma or necrosis. Patient was surgically managed with open excision of the calcified hematoma and rotator cuff arthroscopic repair. At 6 months, supraspinatus muscle was healed, and functional outcome was good. Discussion and Conclusion. We hypothesized that supraspinatus intramuscular calcified hematoma was responsible for mechanical stress on the tendon. This association has never been described.

  2. Tensile tests of 2500-kip prestressing tendons for the PCRV

    International Nuclear Information System (INIS)

    Nicolayeff, V.

    1978-05-01

    A 2500-kip (11-MN) capacity prestressing tendon consisting of sixty 0.5-in. (12.7-mm) strands was designed and tested for General Atomic Company by VSL Corporation of Los Gatos, California. Results of the static tensile test described in this report, and of dynamic tensile tests conducted by VSL in 1968 and 1969, indicate that the tendon system satisfies the requirements of the ASME Boiler and Pressure Vessel Code, Section III, Division 2, and so can be used for prestressing concrete reactor vessels

  3. Human Achilles tendon glycation and function in diabetes

    DEFF Research Database (Denmark)

    Couppe, Christian; Svensson, Rene Brüggebusch; Kongsgaard, Mads

    2016-01-01

    Diabetic patients have an increased risk of foot ulcers, and glycation of collagen may increase tissue stiffness. We hypothesized that the level of glycemic control (glycation) may affect Achilles tendon stiffness, which can influence gait pattern. We therefore investigated the relationship between...... tissue cross-linking were greater in diabetic patients compared to controls. The higher foot pressure indicates that material stiffness of tendon and other tissue (e.g skin and joint capsule) may influence on foot gait. The difference in foot pressure distribution may contribute to the development...... of foot ulcers in diabetic patients....

  4. Testing of large prestressing tendon end anchorage regions

    International Nuclear Information System (INIS)

    Johnson, T.E.

    1976-01-01

    Tests were performed on concrete end anchorage regions for prestressing tendons with ultimate strengths of approximately 8,900 kN. One test structure simulated a full scale concrete containment buttress and the other two test specimens were concrete blocks. The behavior of the test structure and specimens, when subjected to loading, was monitored by strain gages and dial gages. The testing illustrated that all of the amounts of reinforcing tested should be acceptable for the end anchor zones of large tendons presently used in prestressed concrete containment structures. (author)

  5. Influence of repetitive mechanical loading on MMP2 activity in tendon fibroblasts.

    Science.gov (United States)

    Huisman, Elise; Lu, Alex; Jamil, Sarwat; Mousavizadeh, Rouhollah; McCormack, Robert; Roberts, Clive; Scott, Alex

    2016-11-01

    Matrix metalloproteinase2 has been implicated in tendon pathology caused by repetitive movements. However, its activity in the early stages of the tendon's response to overuse, and its presence in the circulation as a possible indicator of tendon degradation, remain unknown. Human tendon cells were repetitively stretched for 5 days, and the rabbit Achilles tendon complex underwent repetitive motion 3× per week for 2 weeks. Quantitative polymer chain reaction analysis was performed to detect matrix metalloproteinase2/14 and tissue inhibitor of matrix metalloproteinase2 messenger ribonucleic acid of cells and rabbit tissue, and matrix metalloproteinase2 protein levels were determined with an enzyme linked immunoassay. Matrix metalloproteinase2 activity was examined using zymography of the conditioned media, tendon and serum. Immunohistochemistry was used to localize matrix metalloproteinase2 in tendon tissue, and the density of fibrillar collagen in tendons was examined using second harmonic generation microscopy. Tendon cells stretched with high strain or high frequency demonstrated increased matrix metalloproteinase2 messenger ribonucleic acid and protein levels. Matrix metalloproteinase2 activity was increased in the rabbit Achilles tendon tissue at weeks 1 and 2; however, serum activity was only increased at week 1. After 2 weeks of exercise, the collagen density was lower in specific regions of the exercised rabbit Achilles tendon complex. Matrix metalloproteinase2 expression in exercised rabbit Achilles tendons was detected surrounding tendon fibroblasts. Repetitive mechanical stimulation of tendon cells results in a small increase in matrix metalloproteinase2 levels, but it appears unlikely that serum matrix metalloproteinase2 will be a useful indicator of tendon overuse injury. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1991-2000, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  6. Tendon material properties vary and are interdependent among turkey hindlimb muscles.

    Science.gov (United States)

    Matson, Andrew; Konow, Nicolai; Miller, Samuel; Konow, Pernille P; Roberts, Thomas J

    2012-10-15

    The material properties of a tendon affect its ability to store and return elastic energy, resist damage, provide mechanical feedback and amplify or attenuate muscle power. While the structural properties of a tendon are known to respond to a variety of stimuli, the extent to which material properties vary among individual muscles remains unclear. We studied the tendons of six different muscles in the hindlimb of Eastern wild turkeys to determine whether there was variation in elastic modulus, ultimate tensile strength and resilience. A hydraulic testing machine was used to measure tendon force during quasi-static lengthening, and a stress-strain curve was constructed. There was substantial variation in tendon material properties among different muscles. Average elastic modulus differed significantly between some tendons, and values for the six different tendons varied nearly twofold, from 829±140 to 1479±106 MPa. Tendons were stretched to failure, and the stress at failure, or ultimate tensile stress, was taken as a lower-limit estimate of tendon strength. Breaking tests for four of the tendons revealed significant variation in ultimate tensile stress, ranging from 66.83±14.34 to 112.37±9.39 MPa. Resilience, or the fraction of energy returned in cyclic length changes was generally high, and one of the four tendons tested was significantly different in resilience from the other tendons (range: 90.65±0.83 to 94.02±0.71%). An analysis of correlation between material properties revealed a positive relationship between ultimate tensile strength and elastic modulus (r(2)=0.79). Specifically, stiffer tendons were stronger, and we suggest that this correlation results from a constrained value of breaking strain, which did not vary significantly among tendons. This finding suggests an interdependence of material properties that may have a structural basis and may explain some adaptive responses observed in studies of tendon plasticity.

  7. Tendinopathy of the long head of the biceps tendon: histopathologic analysis of the extra-articular biceps tendon and tenosynovium

    Directory of Open Access Journals (Sweden)

    Streit JJ

    2015-03-01

    Full Text Available Jonathan J Streit,1 Yousef Shishani,1 Mark Rodgers,2 Reuben Gobezie1 1The Cleveland Shoulder Institute, 2Department of Pathology, University Hospitals of Cleveland, Cleveland, OH, USA Background: Bicipital tendinitis is a common cause of anterior shoulder pain, but there is no evidence that acute inflammation of the extra-articular long head of the biceps (LHB tendon is the root cause of this condition. We evaluated the histologic findings of the extra-articular portion of the LHB tendon and synovial sheath in order to compare those findings to known histologic changes seen in other tendinopathies. Methods: Twenty-six consecutive patients (mean age 45.4±13.7 years underwent an open subpectoral biceps tenodesis for anterior shoulder pain localized to the bicipital groove. Excised tendons were sent for histologic analysis. Specimens were graded using a semiquantitative scoring system to evaluate tenocyte morphology, the presence of ground substance, collagen bundle characteristics, and vascular changes. Results: Chronic inflammation was noted in only two of 26 specimens, and no specimen demonstrated acute inflammation. Tenocyte enlargement and proliferation, characterized by increased roundness and size of the cell and nucleus with proteoglycan matrix expansion and myxoid degenerative changes, was found in all 26 specimens. Abundant ground substance, collagen bundle changes, and increased vascularization were visualized in all samples. Conclusion: Anterior shoulder pain attributed to the biceps tendon does not appear to be due to an inflammatory process in most cases. The histologic findings of the extra-articular portion of the LHB tendon and synovial sheath are similar to the pathologic findings in de Quervain tenosynovitis at the wrist, and may be due to a chronic degenerative process similar to this and other tendinopathies of the body. Keywords: biceps tendinitis, biceps tendinopathy, tenosynovium, anterior shoulder pain, long head biceps

  8. Fascicles and the interfascicular matrix show decreased fatigue life with ageing in energy storing tendons.

    Science.gov (United States)

    Thorpe, Chavaunne T; Riley, Graham P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2017-07-01

    Tendon is composed of rope-like fascicles bound together by interfascicular matrix (IFM). The IFM is critical for the function of energy storing tendons, facilitating sliding between fascicles to allow these tendons to cyclically stretch and recoil. This capacity is required to a lesser degree in positional tendons. We have previously demonstrated that both fascicles and IFM in energy storing tendons have superior fatigue resistance compared with positional tendons, but the effect of ageing on the fatigue properties of these different tendon subunits has not been determined. Energy storing tendons become more injury-prone with ageing, indicating reduced fatigue resistance, hence we tested the hypothesis that the decline in fatigue life with ageing in energy storing tendons would be more pronounced in the IFM than in fascicles. We further hypothesised that tendon subunit fatigue resistance would not alter with ageing in positional tendons. Fascicles and IFM from young and old energy storing and positional tendons were subjected to cyclic fatigue testing until failure, and mechanical properties were calculated. The results show that both IFM and fascicles from the SDFT exhibit a similar magnitude of reduced fatigue life with ageing. By contrast, the fatigue life of positional tendon subunits was unaffected by ageing. The age-related decline in fatigue life of tendon subunits in energy storing tendons is likely to contribute to the increased risk of injury in aged tendons. Full understanding of the mechanisms resulting in this reduced fatigue life will aid in the development of treatments and interventions to prevent age-related tendinopathy. Understanding the effect of ageing on tendon-structure function relationships is crucial for the development of effective preventative measures and treatments for age-related tendon injury. In this study, we demonstrate for the first time that the fatigue resistance of the interfascicular matrix decreases with ageing in energy

  9. Generalization of proposed tendon friction correlation and its application to PCCV structural analysis

    International Nuclear Information System (INIS)

    Kashiwase, Takako; Nagasaka, Hideo

    2000-01-01

    The present paper dealt with the extension of tendon friction coefficient correlation as a function of loading end load and circumferential angle, proposed in the former paper. The extended correlation further included the effects of the number of strands contacted with sheath, tendon diameter, politicization of tendon and tendon local curvature. The validity of the correlation was confirmed by several published measured data. The structural analysis of middle cylinder part of 1/4 PCCV (Prestressed Concrete Containment Vessel) model was conducted using the present friction coefficient correlation. The results were compared with the analysis using constant friction coefficient, focused on the tendon tension force distribution. (author)

  10. PET reconstruction

    International Nuclear Information System (INIS)

    O'Sullivan, F.; Pawitan, Y.; Harrison, R.L.; Lewellen, T.K.

    1990-01-01

    In statistical terms, filtered backprojection can be viewed as smoothed Least Squares (LS). In this paper, the authors report on improvement in LS resolution by: incorporating locally adaptive smoothers, imposing positivity and using statistical methods for optimal selection of the resolution parameter. The resulting algorithm has high computational efficiency relative to more elaborate Maximum Likelihood (ML) type techniques (i.e. EM with sieves). Practical aspects of the procedure are discussed in the context of PET and illustrations with computer simulated and real tomograph data are presented. The relative recovery coefficients for a 9mm sphere in a computer simulated hot-spot phantom range from .3 to .6 when the number of counts ranges from 10,000 to 640,000 respectively. The authors will also present results illustrating the relative efficacy of ML and LS reconstruction techniques

  11. Tendon Reattachment to Bone in an Ovine Tendon Defect Model of Retraction Using Allogenic and Xenogenic Demineralised Bone Matrix Incorporated with Mesenchymal Stem Cells.

    Directory of Open Access Journals (Sweden)

    Tanujan Thangarajah

    Full Text Available Tendon-bone healing following rotator cuff repairs is mainly impaired by poor tissue quality. Demineralised bone matrix promotes healing of the tendon-bone interface but its role in the treatment of tendon tears with retraction has not been investigated. We hypothesized that cortical demineralised bone matrix used with minimally manipulated mesenchymal stem cells will result in improved function and restoration of the tendon-bone interface with no difference between xenogenic and allogenic scaffolds.In an ovine model, the patellar tendon was detached from the tibial tuberosity and a complete distal tendon transverse defect measuring 1 cm was created. Suture anchors were used to reattach the tendon and xenogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5, or allogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5 were used to bridge the defect. Graft incorporation into the tendon and its effect on regeneration of the enthesis was assessed using histomorphometry. Force plate analysis was used to assess functional recovery.Compared to the xenograft, the allograft was associated with significantly higher functional weight bearing at 6 (P = 0.047, 9 (P = 0.028, and 12 weeks (P = 0.009. In the allogenic group this was accompanied by greater remodeling of the demineralised bone matrix into tendon-like tissue in the region of the defect (p = 0.015, and a more direct type of enthesis characterized by significantly more fibrocartilage (p = 0.039. No failures of tendon-bone healing were noted in either group.Demineralised bone matrix used with minimally manipulated mesenchymal stem cells promotes healing of the tendon-bone interface in an ovine model of acute tendon retraction, with superior mechanical and histological results associated with use of an allograft.

  12. The Prevalence and Role of Low Lying Peroneus Brevis Muscle Belly in Patients with Peroneal Tendon Pathologies: A Potential Source for Tendon Subluxation

    OpenAIRE

    Mirmiran, Roya; Squire, Chad; Wassell, Daniel

    2015-01-01

    A low lying peroneus brevis muscle belly is a rare anomaly. There are few published studies that support presence of this anomaly as an etiology for peroneal tendon tear. However, the association between a low lying peroneus muscle belly (LLMB) and tendon subluxation is not well explored. In this retrospective study, the magnetic resonance imaging (MRI) and intraoperative findings of 50 consecutive patients undergoing a primary peroneal tendon surgery, in a five year period, were assessed. Th...

  13. Balloon dilatation in children for oesophageal strictures other than those due to primary repair of oesophageal atresia, interposition or restrictive fundoplication

    International Nuclear Information System (INIS)

    Fasulakis, Stephen; Andronikou, Savvas

    2003-01-01

    Balloon dilatation of the oesophagus in children has been performed predominantly for treating strictures, which are the result of primary repair of oesophageal atresia, interposition surgery or restrictive Nissen's fundoplication. Reports of the use of this technique for alternative causes of stricture are few. To report our experience and success with balloon dilatation of strictures due to caustic ingestion, achalasia, oesophagitis, congenital stenosis, and epidermolysis bullosa (EB) and to make comparisons with our treatment of patients with primary repair of oesophageal atresia (OA), as well as with reports in the English language literature. Retrospective review of fluoroscopically guided balloon oesophageal dilatation procedures in 19 patients over a 5-year period, and comparison of those performed for OA repair complications with those due to other diseases. The average radiation dose, per procedure, was calculated by a medical physicist. Ten patients had strictures as a result of primary repair of OA. Three patients had stricture as a result of EB, two from achalasia, two from caustic injury, one due to an oesophageal web and one from reflux oesophagitis. Our results show that the technique can also be curative for the last group and that it may be used intermittently to alleviate symptoms in ongoing diseases. We h