WorldWideScience

Sample records for real-time sonography fused

  1. Management of threatened abortion with real-time sonography.

    Science.gov (United States)

    Anderson, S G

    1980-02-01

    Real-time sonography was used to evaluate 158 patients with threatened abortion. Fetal motion was first detected during the seventh gestational week and with increasing frequency thereafter in 73 patients with viable pregnancies continuing to term. Only 2 of 65 patients who aborted demonstrated fetal motion. The presence or absence of fetal motion was most reliable after 7 weeks' gestation for establishing a prognosis for a given pregnancy. Seventy-two of 74 pregnancies with fetal motion continued to term, whereas 63 of 64 pregnancies without fetal motion aborted. A method for using real-time sonography in the management of threatened abortion is presented.

  2. Real-time sonography in obstetrics.

    Science.gov (United States)

    Anderson, S G

    1978-03-01

    Three hundred fifty real-time scans were performed on pregnant women for various indications. Placental localization was satisfactorily obtained in 173 of 174 studies. Estimates of fetal gestation from directly measured biparietal diameter were +/-2 weeks of actual gestation in 153 of 172 (88.9%) measurements. The presence or absence of fetal motion and cardiac activity established a diagnosis of fetal viability or fetal death in 32 patients after the first trimester. Accurate diagnosis was made in 52 of 57 patients with threatened abortions, and two of these errors occurred in scans performed before completion of the eighth postmenstrual week. Because of the ability to demonstrate fetal motion, real-time sonography should have many applications in obstetrics.

  3. Biopsy guided by real-time sonography fused with MRI: a phantom study

    DEFF Research Database (Denmark)

    Ewertsen, C.; Grossjohann, Hanne Sønder; Nielsen, Kristina Rue

    2008-01-01

    OBJECTIVE: The purpose of our study was to test the accuracy of sonographically guided biopsies in a phantom of structures not visible on sonography but shown on MRI by using commercially available sonography systems with image fusion software. MATERIALS AND METHODS: A previously recorded MRI...

  4. Radiofrequency Ablation Assisted by Real-Time Virtual Sonography and CT for Hepatocellular Carcinoma Undetectable by Conventional Sonography

    International Nuclear Information System (INIS)

    Nakai, Motoki; Sato, Morio; Sahara, Shinya; Takasaka, Isao; Kawai, Nobuyuki; Minamiguchi, Hiroki; Tanihata, Hirohiko; Kimura, Masashi; Takeuchi, Nozomu

    2009-01-01

    Real-time virtual sonography (RVS) is a diagnostic imaging support system, which provides the same cross-sectional multiplanar reconstruction images as ultrasound images on the same monitor screen in real time. The purpose of this study was to evaluate radiofrequency ablation (RFA) assisted by RVS and CT for hepatocellular carcinoma (HCC) undetectable with conventional sonography. Subjects were 20 patients with 20 HCC nodules not detected by conventional sonography but detectable by CT or MRI. All patients had hepatitis C-induced liver cirrhosis; there were 13 males and 7 females aged 55-81 years (mean, 69.3 years). RFA was performed in the CT room, and the tumor was punctured with the assistance of RVS. CT was performed immediately after puncture, and ablation was performed after confirming that the needle had been inserted into the tumor precisely. The mean number of punctures and success rates of the first puncture were evaluated. Treatment effects were evaluated with dynamic CT every 3 months after RFA. RFA was technically feasible and local tumor control was achieved in all patients. The mean number of punctures was 1.1, and the success rate of the first puncture was 90.0%. This method enabled safe ablation without complications. The mean follow-up period was 13.5 month (range, 9-18 months). No local recurrence was observed at the follow-up points. In conclusion, RFA assisted by RVS and CT is a safe and efficacious method of treatment for HCC undetectable by conventional sonography.

  5. Impact of real-time virtual sonography, a coordinated sonography and MRI system that uses an image fusion technique, on the sonographic evaluation of MRI-detected lesions of the breast in second-look sonography.

    Science.gov (United States)

    Nakano, Shogo; Kousaka, Junko; Fujii, Kimihito; Yorozuya, Kyoko; Yoshida, Miwa; Mouri, Yukako; Akizuki, Miwa; Tetsuka, Rie; Ando, Takahito; Fukutomi, Takashi; Oshima, Yukihiko; Kimura, Junko; Ishiguchi, Tsuneo; Arai, Osamu

    2012-08-01

    The aim of this study was to verify the utility of second-look sonography using real-time virtual sonography (RVS)-a coordinated sonography with an MRI system that uses an image fusion technique with magnetic navigation-on the sonographic evaluation of MRI-detected lesions of the breast. Of the 196 consecutive patients who were examined with breast MRI in our hospital from 2006 to 2009, those patients who underwent second-look sonography to identify MRI-detected lesions were enrolled in this study. MRI was performed using a 1.5-T imager with the patient in a supine position. To assess the efficacy benefits of RVS, the correlations between lesion detection rates, MRI features, distribution, and histopathological classification on second-look sonography using conventional B-mode or RVS were analyzed. Of the 196 patients, 55 (28 %) demonstrated 67 lesions initially detected by MRI, followed by second-look sonography. Of the 67 MRI-detected lesions, 18 (30 %) were identified with second-look sonography using conventional B-mode alone, whereas 60 (90 %) lesions were detected with second-look sonography using RVS (p use of RVS on second-look sonography significantly increases the sonographic detection rate of MRI-detected lesions without operator dependence.

  6. A Real-Time Embedded Control System for Electro-Fused Magnesia Furnace

    Directory of Open Access Journals (Sweden)

    Fang Zheng

    2013-01-01

    Full Text Available Since smelting process of electro-fused magnesia furnace is a complicated process which has characteristics like complex operation conditions, strong nonlinearities, and strong couplings, traditional linear controller cannot control it very well. Advanced intelligent control strategy is a good solution to this kind of industrial process. However, advanced intelligent control strategy always involves huge programming task and hard debugging and maintaining problems. In this paper, a real-time embedded control system is proposed for the process control of electro-fused magnesia furnace based on intelligent control strategy and model-based design technology. As for hardware, an embedded controller based on an industrial Single Board Computer (SBC is developed to meet industrial field environment demands. As for software, a Linux based on Real-Time Application Interface (RTAI is used as the real-time kernel of the controller to improve its real-time performance. The embedded software platform is also modified to support generating embedded code automatically from Simulink/Stateflow models. Based on the proposed embedded control system, the intelligent embedded control software of electro-fused magnesium furnace can be directly generated from Simulink/Stateflow models. To validate the effectiveness of the proposed embedded control system, hardware-in-the-loop (HIL and industrial field experiments are both implemented. Experiments results show that the embedded control system works very well in both laboratory and industry environments.

  7. Real-time virtual sonography (RVS)-guided vacuum-assisted breast biopsy for lesions initially detected with breast MRI.

    Science.gov (United States)

    Uematsu, Takayoshi

    2013-12-01

    To report on our initial experiences with a new method of real-time virtual sonography (RVS)-guided 11-gauge vacuum-assisted breast biopsy for lesions that were initially detected with breast MRI. RVS-guided 11-gauge vacuum-assisted biopsy is performed when a lesion with suspicious characteristics is initially detected with breast MRI and is occult on mammography, sonography, and physical examination. Live sonographic images were co-registered to the previously loaded second-look spine contrast-enhanced breast MRI volume data to correlate the sonography and MR images. Six lesions were examined in six consecutive patients scheduled to undergo RVS-guided 11-gauge vacuum-assisted biopsy. One patient was removed from the study because of non-visualization of the lesion in the second-look spine contrast-enhanced breast MRI. Five patients with non-mass enhancement lesions were biopsied. The lesions ranged in size from 9 to 13 mm (mean 11 mm). The average procedural time, including the sonography and MR image co-registration time, was 25 min. All biopsies resulted in tissue retrieval. One was fibroadenomatous nodules, and those of four were fibrocystic changes. There were no complications during or after the procedures. RVS-guided 11-gauge vacuum-assisted breast biopsies provide a safe and effective method for the examination of suspicious lesions initially detected with MRI.

  8. Advances in the early diagnosis of congenital hip dysplasia by real-time sonography

    Energy Technology Data Exchange (ETDEWEB)

    Brockmann, W.P.; Wilmsdorf, H.v.; Weh, L.; Korn, U.

    1984-05-01

    Twenty-four infants and children aged five days to three years had their hips examined by ultrasound, and in 17 the findings were compared with the radiographic appearances. Real-time sonography, because of its flexibility, is a suitable screening method for the early diagnosis of hip dysplasia. It has the typical characteristics of a screening method: so far there have been no false negative findings. False positive results are rare, but cannot be completely excluded. The patients examined so far were mostly abnormal, and a final assessment of false positive findings will have to await larger clinical material, including normals. 6 figs.

  9. The use of real time ultrasound scanning as a teaching method of anatomy in an undergraduate sonography and medical imaging degree in an Australian university

    International Nuclear Information System (INIS)

    Bowman, A.; Lawson, C.; McKillup, S.

    2016-01-01

    Background: Real-time ultrasound scanning is increasing in popularity as a teaching tool for human anatomy because it is non-invasive, offers real-time 3-D anatomy and is cheaper than dissections. Aim: To assess real-time ultrasound scanning as a teaching method of human anatomy, and to determine what teaching methods medical imaging and sonography students consider effective for understanding human anatomy. Method: Surveys were distributed to two consecutive cohorts of first year medical imaging and medical sonography students at CQUniversity. Participation was voluntary. Comparisons among teaching methods were made using repeated measures ANOVA. Results: Real-time ultrasound scanning was the most preferred method of delivery for anatomy classes overall especially compared to computer programs, videos, 3-D radiological images and dissection. Specifically, students indicated that ultrasound scanning was the preferred method to encourage learning from experience (F 7,231  = 2.942, p = 0.006), to develop team skills (F 7,231  = 4.550, p < 0.006), to follow complex instructions (F 7,231  = 4.656 p < 0.001) and to appreciate anatomical variation (F 7,231  = 2.067, p = 0.048). Dissection was the least favoured teaching method. Conclusion: Real-time ultrasound scanning is a useful tool for teaching anatomy, and animal dissections are a poor substitute for the use of human cadavers. - Highlights: • Real-time ultrasound scanning is a valid teaching tool for human anatomy. • Real-time ultrasound is preferred by students compared to other teaching methods. • Dissection is the least favoured method to learn anatomy. • Ultrasound encourages learning from experience and develops team skills.

  10. Radiofrequency ablation assisted by real-time virtual sonography for hepatocellular carcinoma inconspicuous under sonography and high-risk locations

    Directory of Open Access Journals (Sweden)

    Cheng-Han Lee

    2015-08-01

    Full Text Available Radiofrequency ablation (RFA is an effective and real-time targeting modality for small hepatocellular carcinomas (HCCs. However, mistargeting may occur when the target tumor is confused with cirrhotic nodules or because of the poor conspicuity of the index tumor under ultrasonography (US. Real-time virtual sonography (RVS can provide the same reconstruction computed tomography images as US images. The aim of this study is to investigate the usefulness of RVS-assisted RFA for HCCs that are inconspicuous or conspicuous under US. A total of 21 patients with 28 HCC tumors—divided into US inconspicuous and high-risk subgroup (3 tumors in 3 patients, US inconspicuous and nonhigh-risk subgroup (5 tumors in 4 patients, US conspicuous and high-risk subgroup (16 tumors in 14 patients, and US conspicuous and nonhigh-risk subgroup (4 tumors in 3 patients—underwent RVS-assisted RFA between May 2012 and June 2014 in our institution. The mean diameter of the nodules was 2.0 ± 1.1 cm. The results showed that the complete ablation rate is 87.5% (7/8 in the US undetectable group and 75% (15/20 in the US detectable group. A comparison between six tumors with incomplete ablation and 22 tumors with complete ablation showed higher alpha-fetoprotein level (mean, 1912 ng/mL vs. 112 ng/mL and larger tumor size (mean diameter, 26 mm vs. 16 mm in the incomplete ablation nodules (both p < 0.05. In conclusion, RVS-assisted RFA is useful for tumors that are difficult to detect under conventional US and may also be useful for tumors in high-risk locations because it may prevent complication induced by mistargeting.

  11. Real-time virtual sonography for navigation during targeted prostate biopsy using magnetic resonance imaging data

    International Nuclear Information System (INIS)

    Miyagawa, Tomoaki; Ishikawa, Satoru; Kimura, Tomokazu; Suetomi, Takahiro; Tsutsumi, Masakazu; Irie, Toshiyuki; Kondoh, Masanao; Mitake, Tsuyoshi

    2010-01-01

    The objective of this study was to evaluate the effectiveness of the medical navigation technique, namely, Real-time Virtual Sonography (RVS), for targeted prostate biopsy. Eighty-five patients with suspected prostate cancer lesions using magnetic resonance imaging (MRI) were included in this study. All selected patients had at least one negative result on the previous transrectal biopsies. The acquired MRI volume data were loaded onto a personal computer installed with RVS software, which registers the volumes between MRI and real-time ultrasound data for real-time display. The registered MRI images were displayed adjacent to the ultrasonographic sagittal image on the same computer monitor. The suspected lesions on T2-weighted images were marked with a red circle. At first suspected lesions were biopsied transperineally under real-time navigation with RVS and then followed by the conventional transrectal and transperineal biopsy under spinal anesthesia. The median age of the patients was 69 years (56-84 years), and the prostate-specific antigen level and prostate volume were 9.9 ng/mL (4.0-34.2) and 37.2 mL (18-141), respectively. Prostate cancer was detected in 52 patients (61%). The biopsy specimens obtained using RVS revealed 45/52 patients (87%) positive for prostate cancer. A total of 192 biopsy cores were obtained using RVS. Sixty-two of these (32%) were positive for prostate cancer, whereas conventional random biopsy revealed cancer only in 75/833 (9%) cores (P<0.01). Targeted prostate biopsy with RVS is very effective to diagnose lesions detected with MRI. This technique only requires additional computer and RVS software and thus is cost-effective. Therefore, RVS-guided prostate biopsy has great potential for better management of prostate cancer patients. (author)

  12. The burning fuse model of unbecoming in time

    Science.gov (United States)

    Norton, John D.

    2015-11-01

    In the burning fuse model of unbecoming in time, the future is real and the past is unreal. It is used to motivate the idea that there is something unbecoming in the present literature on the metaphysics of time: its focus is merely the assigning of a label "real."

  13. FPGA-based Fused Smart Sensor for Real-Time Plant-Transpiration Dynamic Estimation

    Directory of Open Access Journals (Sweden)

    Irineo Torres-Pacheco

    2010-09-01

    Full Text Available Plant transpiration is considered one of the most important physiological functions because it constitutes the plants evolving adaptation to exchange moisture with a dry atmosphere which can dehydrate or eventually kill the plant. Due to the importance of transpiration, accurate measurement methods are required; therefore, a smart sensor that fuses five primary sensors is proposed which can measure air temperature, leaf temperature, air relative humidity, plant out relative humidity and ambient light. A field programmable gate array based unit is used to perform signal processing algorithms as average decimation and infinite impulse response filters to the primary sensor readings in order to reduce the signal noise and improve its quality. Once the primary sensor readings are filtered, transpiration dynamics such as: transpiration, stomatal conductance, leaf-air-temperature-difference and vapor pressure deficit are calculated in real time by the smart sensor. This permits the user to observe different primary and calculated measurements at the same time and the relationship between these which is very useful in precision agriculture in the detection of abnormal conditions. Finally, transpiration related stress conditions can be detected in real time because of the use of online processing and embedded communications capabilities.

  14. FPGA-based Fused Smart Sensor for Real-Time Plant-Transpiration Dynamic Estimation

    Science.gov (United States)

    Millan-Almaraz, Jesus Roberto; de Jesus Romero-Troncoso, Rene; Guevara-Gonzalez, Ramon Gerardo; Contreras-Medina, Luis Miguel; Carrillo-Serrano, Roberto Valentin; Osornio-Rios, Roque Alfredo; Duarte-Galvan, Carlos; Rios-Alcaraz, Miguel Angel; Torres-Pacheco, Irineo

    2010-01-01

    Plant transpiration is considered one of the most important physiological functions because it constitutes the plants evolving adaptation to exchange moisture with a dry atmosphere which can dehydrate or eventually kill the plant. Due to the importance of transpiration, accurate measurement methods are required; therefore, a smart sensor that fuses five primary sensors is proposed which can measure air temperature, leaf temperature, air relative humidity, plant out relative humidity and ambient light. A field programmable gate array based unit is used to perform signal processing algorithms as average decimation and infinite impulse response filters to the primary sensor readings in order to reduce the signal noise and improve its quality. Once the primary sensor readings are filtered, transpiration dynamics such as: transpiration, stomatal conductance, leaf-air-temperature-difference and vapor pressure deficit are calculated in real time by the smart sensor. This permits the user to observe different primary and calculated measurements at the same time and the relationship between these which is very useful in precision agriculture in the detection of abnormal conditions. Finally, transpiration related stress conditions can be detected in real time because of the use of online processing and embedded communications capabilities. PMID:22163656

  15. Neonatal periventricular leukomalacia: real-time sonographic diagnosis with CT correlation

    International Nuclear Information System (INIS)

    Chow, P.P.; Horgan, J.G.; Taylor, K.J.W.

    1985-01-01

    The utility of real-time sonography in the diagnosis of neonatal periventricular leukomalacia (PVL) has been described only recently. Six cases are reported of PVL diagnosed by serial real-time scanning. The sonographic findings were correlated with the computed tomographic findings and the clinical history. In five of six infants in whom scanning was performed, characteristic multiseptated periventricular cavitations developed 2-3 weeks after birth or later. A transition from normal to increased periventricular echogenicity was often observed before the development of the periventricular cavitations in nonhemorrhagic PVL. The parenchymal abnormality demonstrated by sonography correlated well with an abnormal neurologic outcome. It is suggested that serial real-time scanning be performed in neonates whose history suggests the possibility of hypoxic-ischemic brain injury. Nonspecific predictors of PVL include seizures, apnea, disturbed mental status, abnormal muscle tone, and leg weakness

  16. A New Navigation System of Renal Puncture for Endoscopic Combined Intrarenal Surgery: Real-time Virtual Sonography-guided Renal Access.

    Science.gov (United States)

    Hamamoto, Shuzo; Unno, Rei; Taguchi, Kazumi; Ando, Ryosuke; Hamakawa, Takashi; Naiki, Taku; Okada, Shinsuke; Inoue, Takaaki; Okada, Atsushi; Kohri, Kenjiro; Yasui, Takahiro

    2017-11-01

    To evaluate the clinical utility of a new navigation technique for percutaneous renal puncture using real-time virtual sonography (RVS) during endoscopic combined intrarenal surgery. Thirty consecutive patients who underwent endoscopic combined intrarenal surgery for renal calculi, between April 2014 and July 2015, were divided into the RVS-guided puncture (RVS; n = 15) group and the ultrasonography-guided puncture (US; n = 15) group. In the RVS group, renal puncture was repeated until precise piercing of a papilla was achieved under direct endoscopic vision, using the RVS system to synchronize the real-time US image with the preoperative computed tomography image. In the US group, renal puncture was performed under US guidance only. In both groups, 2 urologists worked simultaneously to fragment the renal calculi after inserting the miniature percutaneous tract. The mean sizes of the renal calculi in the RVS and the US group were 33.5 and 30.5 mm, respectively. A lower mean number of puncture attempts until renal access through the calyx was needed for the RVS compared with the US group (1.6 vs 3.4 times, respectively; P = .001). The RVS group had a lower mean postoperative hemoglobin decrease (0.93 vs 1.39 g/dL, respectively; P = .04), but with no between-group differences with regard to operative time, tubeless rate, and stone-free rate. None of the patients in the RVS group experienced postoperative complications of a Clavien score ≥2, with 3 patients experiencing such complications in the US group. RVS-guided renal puncture was effective, with a lower incidence of bleeding-related complications compared with US-guided puncture. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Three-dimensional power Doppler sonography in screening for carotid artery disease.

    Science.gov (United States)

    Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D

    2000-01-01

    Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.

  18. Comparison of sonography and venography in the diagnosis of lower extremity deep venous thrombosis

    International Nuclear Information System (INIS)

    Mostbeck, G.H.; Kettenbach, J.; Henk, C.

    1993-01-01

    In recent years, non-invasive sonographic techniques [real-time ultrasound (US), duplex ultrasonography (DU) and color-coded duplex sonography (CCDS)] have increased in importance for the diagnosis of lower extremity deep venous thrombosis. To ascertain the accuracy and limitations of these techniques prospectively, various studies have been performed to compare sonography with venography. This review deals with basic methodologic considerations when two imaging methds are compared and describes the features of deep venous thrombosis seen on US, DU and CCDS. Reports comparing sonography and phlebography for the diagnosis of deep venous thrombosis are presented and discussed. The advantages and limitations of US, DU and CCDS for the diagnosis of iliac, femoral, popliteal and infrapopliteal venous thrombosis are compared with those of venography, and controversial areas are touched on. (orig.) [de

  19. Perforated pyloroduodenal peptic ulcer and sonography.

    Science.gov (United States)

    Kuzmich, Siarhei; Harvey, Chris J; Fascia, Daniel T M; Kuzmich, Tatsiana; Neriman, Deena; Basit, Rizwan; Tan, Kai Lee

    2012-11-01

    The purpose of this article is to illustrate the spectrum of sonographic findings in perforated pyloroduodenal peptic ulcer and discuss the potential role of sonography in the diagnosis. Although sonography is not the first-line investigation of choice in suspected perforated peptic ulcer, understanding of the characteristic appearances seen during general abdominal sonography may aid the reader in the diagnosis of this important and sometimes overlooked cause of nonspecific abdominal pain. This may shorten time to the diagnosis and ultimate surgical management.

  20. Local recurrences after conservative surgery and irradiation for breast cancer: Diagnosis with mammography and ultrasound. Mammographie und Sonographie in der Rezidivdiagnostik nach brusterhaltender Therapie des Mammakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Buchberger, W; Hamberger, L; Schoen, G [Innsbruck Univ. (Austria). Universitaetsklinik fuer Radiodiagnostik; Steixner, G; Fritsch, E [Innsbruck Univ. (Austria). Universitaetsklinik fuer Strahlentherapie

    1991-06-01

    89 patients, who underwent conservative surgery for breast cancer were followed up with mammography and real-time sonography. 78 patients underwent postoperative irradiation. Depending on the time interval between irradiation and examination various alterations in mammographic and sonographic patterns were evident. Of 14 biospy-confirmed local recurrences, 11 were diagnosed by mammography and 12 by sonography. Combined use of mammography and sonography should therefore lead to better results in the diagnosis of local recurrences and to a reduction of unnecessary biopsies. (orig./GDG).

  1. 10 MHz b-scan sonography of the cervical carotid arteries

    International Nuclear Information System (INIS)

    Kuhn, F.P.; Kraemer, G.; Bauer, R.; Klotter, H.J.; Mainz Univ.; Mainz Univ.

    1984-01-01

    Two hundred and eighty-two consecutive patients with cerebro-vascular insufficiency, with non-specific neurological symptoms or asymptomatic murmurs, were examined prospectively by two-dimensional high resolution 10 MHz B-scan real time sonography. Arteriosclerotic plaques were usually semi-circular (77%), of high amplitude (64%) and homogeneous (80%). Ulcerating plaques were correctly diagnosed in only three out of eight cases demonstrated angiographically. So far there has been no definite relationship between the appearance of the plaques and clinical symptoms. Compared with arteriography (170 examinations) the specificity of sonography was 98% (62/63), the sensitivity for plaques was 100% (50/50), for stenoses it was 63% (5/8) to 93% (14/15), for occlusions it was 76% (13/17). The indications and drawbacks of the method are discussed. (orig.) [de

  2. Robust Real-Time Tracking for Visual Surveillance

    Directory of Open Access Journals (Sweden)

    Aguilera Josep

    2007-01-01

    Full Text Available This paper describes a real-time multi-camera surveillance system that can be applied to a range of application domains. This integrated system is designed to observe crowded scenes and has mechanisms to improve tracking of objects that are in close proximity. The four component modules described in this paper are (i motion detection using a layered background model, (ii object tracking based on local appearance, (iii hierarchical object recognition, and (iv fused multisensor object tracking using multiple features and geometric constraints. This integrated approach to complex scene tracking is validated against a number of representative real-world scenarios to show that robust, real-time analysis can be performed.

  3. A radiologist's guide to the imaging in the diagnosis and treatment of developmental dysplasia of the hip. Pt. 1. General considerations, physical examination as applied to real-time sonography and radiography

    International Nuclear Information System (INIS)

    Gerscovich, E.O.

    1997-01-01

    Developmental dysplasia of the hip (DDH) has a broad spectrum of presentation with the minor findings resolving spontaneously and the most severe ones resulting in disability, if not diagnosed early in life. Diagnosis in the first few months of life allows conservative treatment with complete resolution in most cases. Suspicion of DDH is based on ethnic, family, and pregnancy history, and on physical examination of the newborn. Imaging assists in the diagnosis and follows the treatment. Different modalities have their own advantages and disadvantages. This article deals with the description of the disease, risk factors, statistics, the physical examination as applied to real-time sonography, and imaging (plain radiography, arthrography, computed tomography, and magnetic resonance imaging). (orig.). With 26 figs., 1 tab

  4. A radiologist`s guide to the imaging in the diagnosis and treatment of developmental dysplasia of the hip. Pt. 1. General considerations, physical examination as applied to real-time sonography and radiography

    Energy Technology Data Exchange (ETDEWEB)

    Gerscovich, E.O. [Department of Radiology, University of California, Davis Medical Center, 2516 Stockton Blvd., Ticon II Building, Sacramento, CA 95817 (United States)

    1997-07-07

    Developmental dysplasia of the hip (DDH) has a broad spectrum of presentation with the minor findings resolving spontaneously and the most severe ones resulting in disability, if not diagnosed early in life. Diagnosis in the first few months of life allows conservative treatment with complete resolution in most cases. Suspicion of DDH is based on ethnic, family, and pregnancy history, and on physical examination of the newborn. Imaging assists in the diagnosis and follows the treatment. Different modalities have their own advantages and disadvantages. This article deals with the description of the disease, risk factors, statistics, the physical examination as applied to real-time sonography, and imaging (plain radiography, arthrography, computed tomography, and magnetic resonance imaging). (orig.). With 26 figs., 1 tab.

  5. The Natural History of Kidney Graft Cortical Microcirculation Determined by Real-Time Contrast-Enhanced Sonography (RT-CES).

    Science.gov (United States)

    Jiménez, Carlos; López, María Ovidia; Ros, Amaia; Aguilar, Ana; Menendez, David; Rivas, Begoña; Santana, María José; Vaca, Marco Antonio; Escuin, Fernando; Madero, Rosario; Selgas, Rafael

    2016-01-01

    Kidney transplantation is the therapy of choice for end-stage kidney disease. Graft's life span is shorter than expected due in part to the delayed diagnosis of various complications, specifically those related to silent progression. It is recognized that serum creatinine levels and proteinuria are poor markers of mild kidney lesions, which results in delayed clinical information. There are many investigation looking for early markers of graft damage. Decreasing kidney graft cortical microcirculation has been related to poor prognosis in kidney transplantation. Cortical capillary blood flow (CCBF) can be measured by real-time contrast-enhanced sonography (RT-CES). Our aim was to describe the natural history of CCBF over time under diverse conditions of kidney transplantation, to explore the influence of donor conditions and recipient events, and to determine the capacity of CCBF for predicting renal function in medium term. RT-CES was performed in 79 consecutive kidney transplant recipients during the first year under regular clinical practice. Cortical capillary blood flow was measured. Clinical variables were analyzed. The influence of CCBF has been determined by univariate and multivariate analysis using mixed regression models based on sequential measurements for each patient over time. We used a first-order autoregression model as the structure of the covariation between measures. The post-hoc comparisons were considered using the Bonferroni correction. The CCBF values varied significantly over the study periods and were significantly lower at 48 h and day 7. Brain-death donor age and CCBF levels showed an inverse relationship (r: -0.62, p<0.001). Living donors showed higher mean CCBF levels than brain-death donors at each point in the study. These significant differences persisted at month 12 (54.5 ± 28.2 vs 33.7 ± 30 dB/sec, living vs brain-death donor, respectively, p = 0.004) despite similar serum creatinine levels (1.5 ± 0.3 and 1.5 ± 0.5 mg/dL). A

  6. Comparison of computerized tomography to sonography, applied in diseases of the pancreas

    International Nuclear Information System (INIS)

    Kluge, K.

    1982-01-01

    The examination results of 418 patients whose epigastria had been examined both by computerized tomography and sonography over 1 week in the time from beginning January 1978 until and of July 1979 were compared with regard to the imaging of the pancreas, reliability, and the specificity and sensitivity in establishing the diagnosis. For the sonographic examination, a compound and a real-time unit were used; the computerized tomography was carried out by means of an equipment of the 3rd generation with a scan time of 4 sec. The screening of the pancreas was significantly better using computerized tomography (99.3% US. 84% with US). As for accuracy, computerized tomography had 92.5% exact diagnoses versus 79.9% obtained by sonography. If, however, we look at the cases in which the pancreas could be screened with both methods the accuracy was almost the same (93.7 CT and 93.3% US). Specificity was almost of the same quality, however, the method of computerized tomography with 0.963 was slightly better than ultrasound with 0.943. As for sensitivity, sonography with 0.838 was better than CT with 0.721. The reason for that is the fact that a big part of the chronic pancreatites (30.3%) were not recognized by means of computerized tomography. (orig.) [de

  7. GNSS global real-time augmentation positioning: Real-time precise satellite clock estimation, prototype system construction and performance analysis

    Science.gov (United States)

    Chen, Liang; Zhao, Qile; Hu, Zhigang; Jiang, Xinyuan; Geng, Changjiang; Ge, Maorong; Shi, Chuang

    2018-01-01

    Lots of ambiguities in un-differenced (UD) model lead to lower calculation efficiency, which isn't appropriate for the high-frequency real-time GNSS clock estimation, like 1 Hz. Mixed differenced model fusing UD pseudo-range and epoch-differenced (ED) phase observations has been introduced into real-time clock estimation. In this contribution, we extend the mixed differenced model for realizing multi-GNSS real-time clock high-frequency updating and a rigorous comparison and analysis on same conditions are performed to achieve the best real-time clock estimation performance taking the efficiency, accuracy, consistency and reliability into consideration. Based on the multi-GNSS real-time data streams provided by multi-GNSS Experiment (MGEX) and Wuhan University, GPS + BeiDou + Galileo global real-time augmentation positioning prototype system is designed and constructed, including real-time precise orbit determination, real-time precise clock estimation, real-time Precise Point Positioning (RT-PPP) and real-time Standard Point Positioning (RT-SPP). The statistical analysis of the 6 h-predicted real-time orbits shows that the root mean square (RMS) in radial direction is about 1-5 cm for GPS, Beidou MEO and Galileo satellites and about 10 cm for Beidou GEO and IGSO satellites. Using the mixed differenced estimation model, the prototype system can realize high-efficient real-time satellite absolute clock estimation with no constant clock-bias and can be used for high-frequency augmentation message updating (such as 1 Hz). The real-time augmentation message signal-in-space ranging error (SISRE), a comprehensive accuracy of orbit and clock and effecting the users' actual positioning performance, is introduced to evaluate and analyze the performance of GPS + BeiDou + Galileo global real-time augmentation positioning system. The statistical analysis of real-time augmentation message SISRE is about 4-7 cm for GPS, whlile 10 cm for Beidou IGSO/MEO, Galileo and about 30 cm

  8. Intelligent navigation to improve obstetrical sonography.

    Science.gov (United States)

    Yeo, Lami; Romero, Roberto

    2016-04-01

    'Manual navigation' by the operator is the standard method used to obtain information from two-dimensional and volumetric sonography. Two-dimensional sonography is highly operator dependent and requires extensive training and expertise to assess fetal anatomy properly. Most of the sonographic examination time is devoted to acquisition of images, while 'retrieval' and display of diagnostic planes occurs rapidly (essentially instantaneously). In contrast, volumetric sonography has a rapid acquisition phase, but the retrieval and display of relevant diagnostic planes is often time-consuming, tedious and challenging. We propose the term 'intelligent navigation' to refer to a new method of interrogation of a volume dataset whereby identification and selection of key anatomical landmarks allow the system to: 1) generate a geometrical reconstruction of the organ of interest; and 2) automatically navigate, find, extract and display specific diagnostic planes. This is accomplished using operator-independent algorithms that are both predictable and adaptive. Virtual Intelligent Sonographer Assistance (VIS-Assistance®) is a tool that allows operator-independent sonographic navigation and exploration of the surrounding structures in previously identified diagnostic planes. The advantage of intelligent (over manual) navigation in volumetric sonography is the short time required for both acquisition and retrieval and display of diagnostic planes. Intelligent navigation technology automatically realigns the volume, and reorients and standardizes the anatomical position, so that the fetus and the diagnostic planes are consistently displayed in the same manner each time, regardless of the fetal position or the initial orientation. Automatic labeling of anatomical structures, subject orientation and each of the diagnostic planes is also possible. Intelligent navigation technology can operate on conventional computers, and is not dependent on specific ultrasound platforms or on the

  9. Three-dimensional versus two-dimensional sonography of the temporomandibular joint in comparison to MRI

    Energy Technology Data Exchange (ETDEWEB)

    Landes, Constantin A. [Oral, Maxillofacial and Plastic Facial Surgery, Frankfurt University Medical Centre, Theodor-Stern-Kai 7, 60596 Frankfurt (Germany)]. E-mail: c.landes@lycos.com; Goral, Wojciech A. [Oral, Maxillofacial and Plastic Facial Surgery, Frankfurt University Medical Centre, Theodor-Stern-Kai 7, 60596 Frankfurt (Germany)]. E-mail: w.goral@gmx.de; Sader, Robert [Oral, Maxillofacial and Plastic Facial Surgery, Frankfurt University Medical Centre, Theodor-Stern-Kai 7, 60596 Frankfurt (Germany)]. E-mail: r.sader@em.uni-frankfurt.de; Mack, Martin G. [Department of Diagnostic and Interventional Radiology, Frankfurt University Medical Centre, Theodor-Stern-Kai 7, 60596 Frankfurt (Germany)]. E-mail: martinmack@arcor.de

    2007-02-15

    Aim: To compare clinical feasibility of static two-dimensional (2D) to three-dimensional (3D) sonography of the temporomandibular joint (TMJ) in assessment of disk dislocation and joint degeneration compared to magnetic resonance imaging (MRI). Method: Thirty-three patients, 66 TMJ were prospectively sonographed 2D and 3D (8-12.5 MHz step motor scan), in occlusion and maximum opening with a probe position parallel inferior to the zygomatic arch. Axial 2D images were judged independent from the 3D scans; 3D volumes were cut axial, sagittal, frontal and rotated in real-time. Disk position and joint degeneration were assessed and compared to a subsequent MRI examination. Results: The specific appearance of the disk was hypoechogenic overlying a hyperechogenic condyle in axial (2D) or sagittal and frontal (3D) viewing. Specificity of 2D sonography for disk dislocation was 63%, sensitivity 58%, accuracy 64%, positive predictive value 46%, negative predictive value 73%; for joint degeneration synonymously 59/68/61/38/83%. 3D sonography for disk displacement reached synonymously 68/60/69/51/76%, for joint degeneration 75/65/73/48/86%. 2D sonographic diagnoses of disk dislocation in the closed mouth position and of joint degeneration showed significantly different results from the expected values (MRI) in {chi} {sup 2} testing; 3D diagnoses of disk dislocation in closed mouth position, of joint degeneration, 2D and 3D diagnoses in open mouth position were nonsignificant. Conclusions: Acceptable was the overall negative predictive value, as specificity and accuracy for joint degeneration in 3D. 3D appears superior diagnosing disk dislocation in closed mouth position as for overall joint degeneration. Sensitivity, accuracy and positive predictive value will have to ameliorate with future equipment of higher resolution in real-time 2D and 3D, if sonographic screening shall be clinically applied prior to MRI.

  10. Deginerative changes of femoral articular cartilage in the knee : comparative study of specimen sonography and pathology

    International Nuclear Information System (INIS)

    Park, Ju Youn; Hong, Sung Hwan; Sohn, Jin Hee; Wee, Young Hoon; Chang, Jun Dong; Park, Hong Seok; Lee, Eil Seoung; Kang Ik Won

    2001-01-01

    To determine the sonographic findings of degenerative change in femoral articular cartilage of the knee by comparative study of specimen sonography and pathology. We obtained 40 specimens of cartilage of the femur (20 medial and 20 lateral condylar) from 20 patients with osteoarthritis of the knee who had undergone total knee replacement. The specimens were placed in a saline-filled container and sonography was performed using a 10-MHz linear transducer. Sonographic abnormalities were evaluated at the cartilage surface, within the cartilage, and at the bone-cartilage interface, and were compared with the corresponding pathologic findings. In addition, cartilage thickness was measured at a representative portion of each femoral cartilage specimen and was compared with the thickness determined by sonography. 'Dot' lesions, irregularity or loss of the hyperechoic line, were demonstrated by sonography at the saline-cartilage interface of 14 cartilages. Pathologic examination showed that these findings corresponded to cleft, detachment, erosion, and degeneration. Irregularities in the hyperechoic line at the bone-cartilage interface were revealed by sonography in eight cartilages and were related to irregularity or loss of tidemark, downward displacement of the cartilage, and subchondral callus formation. Dot lesions, corresponding to cleft and degeneration, were noted within one cartilage. Cartilage thickness measured on specimen and by sonography showed no significant difference (p=0.446). Specimen sonography suggested that articular cartilage underwent degenerative histopathological change. Cartilage thickness measured by sonography exactly reflected real thickness

  11. Synchronous gastric neuroendocrine carcinoma and hepatocellular carcinoma

    DEFF Research Database (Denmark)

    Ewertsen, Caroline; Henriksen, Birthe Merete; Hansen, Carsten Palnæs

    2009-01-01

    of synchronous gastric NEC and hepatocellular carcinoma in a patient with several other precancerous lesions is presented. The patient had anaemia, and a gastric tumour and two duodenal polyps were identified on upper endoscopy. A CT scan of the abdomen revealed several lesions in the liver. The lesions were...... invisible on B-mode sonography and real-time sonography fused with CT was used to identify and biopsy one of the lesions. Histology showed hepatocellular carcinoma. A literature search showed that only one case of a hepatocellular carcinoma synchronous with a gastric NEC has been reported previously. TRIAL...

  12. Hepatic Vein Arrival Time for Diagnosis of Liver Cirrhosis: A 10-Year Single-Center Experience With Contrast-Enhanced Sonography.

    Science.gov (United States)

    Abbattista, Teresa; Ridolfi, Francesco; Consalvo, Giovanni Traina; Brunelli, Eugenio

    2016-10-01

    To evaluate the performance of contrast-enhanced sonography with a second-generation contrast agent in assessing the severity of chronic diffuse liver disease and differentiating cirrhotic from noncirrhotic liver disease. Contrast-enhanced sonography was performed after intravenous bolus injection of a second-generation contrast agent in 14 healthy control participants and 160 consecutive patients with cirrhotic and noncirrhotic liver disease (n = 78 and 82, respectively) enrolled between March 2004 and April 2014. The intensity of enhancement in a main hepatic vein was used to determine hepatic vein arrival time, time to peak intensity, and peak contrast enhancement. The hepatic vein arrival time was lower in cirrhotic patients compared with both noncirrhotic patients and controls (mean ± SD, 15.0 ± 2.8, 21.5 ± 3.4, and 25.6 ± 4.7 seconds, respectively; P < .05). The hepatic vein arrival time in noncirrhotic patients was also significantly lower than that in controls (P < .05). The time to peak intensity was significantly lower in cirrhotic patients compared with noncirrhotic patients and controls (40.7 ± 13.7, 49.4 ± 12.8, and 51.2 ± 13.7 seconds; P < .05). A receiver operating characteristic curve analysis revealed that the hepatic vein arrival time more accurately excluded a diagnosis of liver cirrhosis than the time to peak intensity (area under the receiver operating characteristic curve, 0.953 versus 0.694). Specifically, a hepatic vein arrival time cutoff value of 17 seconds excluded liver cirrhosis with 91.1% sensitivity and 93.6% specificity. Contrast-enhanced sonography is a valid alternative method for noninvasive staging of liver diseases. The hepatic vein arrival time could be used to exclude liver cirrhosis in a clinical setting.

  13. Brain sonography in African infants with complicated sporadic ...

    African Journals Online (AJOL)

    Background: To determine the structural findings in brain sonography of African infants with complicated sporadic bacterial meningitis. Materials and Methods: Retrospective assessment of medical records of patients who underwent brain sonography on account of complicated bacterial meningitis. The brain sonography ...

  14. Treatment response assessment of radiofrequency ablation for hepatocellular carcinoma: Usefulness of virtual CT sonography with magnetic navigation

    International Nuclear Information System (INIS)

    Minami, Yasunori; Kitai, Satoshi; Kudo, Masatoshi

    2012-01-01

    Purpose: Virtual CT sonography using magnetic navigation provides cross sectional images of CT volume data corresponding to the angle of the transducer in the magnetic field in real-time. The purpose of this study was to clarify the value of this virtual CT sonography for treatment response of radiofrequency ablation for hepatocellular carcinoma. Patients and methods: Sixty-one patients with 88 HCCs measuring 0.5–1.3 cm (mean ± SD, 1.0 ± 0.3 cm) were treated by radiofrequency ablation. For early treatment response, dynamic CT was performed 1–5 days (median, 2 days). We compared early treatment response between axial CT images and multi-angle CT images using virtual CT sonography. Results: Residual tumor stains on axial CT images and multi-angle CT images were detected in 11.4% (10/88) and 13.6% (12/88) after the first session of RFA, respectively (P = 0.65). Two patients were diagnosed as showing hyperemia enhancement after the initial radiofrequency ablation on axial CT images and showed local tumor progression shortly because of unnoticed residual tumors. Only virtual CT sonography with magnetic navigation retrospectively showed the residual tumor as circular enhancement. In safety margin analysis, 10 patients were excluded because of residual tumors. The safety margin more than 5 mm by virtual CT sonographic images and transverse CT images were determined in 71.8% (56/78) and 82.1% (64/78), respectively (P = 0.13). The safety margin should be overestimated on axial CT images in 8 nodules. Conclusion: Virtual CT sonography with magnetic navigation was useful in evaluating the treatment response of radiofrequency ablation therapy for hepatocellular carcinoma.

  15. Real-time elastography with a novel quantitative technology for assessment of liver fibrosis in chronic hepatitis B

    International Nuclear Information System (INIS)

    Wang Juan; Guo Long; Shi Xiuying; Pan Wenqian; Bai Yunfei; Ai Hong

    2012-01-01

    Background: The accurate evaluation of liver fibrosis stage is important in determining the treatment strategy. The limitations of percutaneous liver biopsy as the gold standard are obvious for invasion. Real-time elastography with conventional ultrasound probes and a new quantitative technology for diffuse histological lesion is a novel approach for staging of liver fibrosis. Purpose: This study aimed to evaluate the value of real-time tissue elastography with a new quantitative technology for the assessment of liver fibrosis stage. Materials and methods: Real-time elastography was performed in 55 patients with liver fibrosis and chronic hepatitis B and in 20 healthy volunteers. Eleven parameters for every patient in colorcode image obtained from the real-time elastography were analyzed with principal components analysis. We analyzed the correlation between elasticity index and liver fibrosis stage and the accuracy of real-time elastography for liver fibrosis staging. Additionally, aspartate transaminase-to-platelet ratio index was also included in the analysis. Results: The Spearman's correlation coefficient between the elasticity index and the histologic fibrosis stage was 0.81, which is highly significant (p 0.05), respectively. Conclusions: Real-time elastography with a new quantitative technology for diffuse histological lesion is a new and promising sonography-based noninvasive method for the assessment of liver fibrosis in patients with chronic hepatitis B.

  16. High-resolution real-time sonography and MR imaging in assessment of osteocartilaginous exostoses

    International Nuclear Information System (INIS)

    Prayer, L.M.; Kropej, D.H.; Wimberger, D.M.; Wurnig, C.F.; Kramer, J.; Kainberger, F.M.; Braun, O.H.; Ritschl, P.W.; Imhof, H.

    1991-01-01

    High-resolution real-time ultrasonography (US) and MR imaging, using both spin-echo (SE) and gradient-echo (GE) sequences, were performed prospectively in 14 patients with solitary osteocartilaginous exostoses to assess cartilage cap thickness and bursa formation. Results were compared to surgical and histopathologic findings in all cases. Both US and MR imaging were useful in evaluating exostotic cartilage cap thickness, which is supposed to be the most reliable sign of malignant transformation. Hyaline cartilage matrix had distinctive features in US and MR imaging caused by its specific histologic composition. The formation of bursae over the protruding exostoses, which results in pain and clinically could raise the suspicion of growth and malignant transformation, was demonstrated best using GE sequences. MR imaging was thus superior to US in the detection of bursa formation. (orig.)

  17. High-resolution real-time sonography and MR imaging in assessment of osteocartilaginous exostoses

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, L.M.; Kropej, D.H.; Wimberger, D.M.; Wurnig, C.F.; Kramer, J.; Kainberger, F.M.; Braun, O.H.; Ritschl, P.W.; Imhof, H. (Vienna Univ. (Austria). Depts. of Radiology, Orthopedic Surgery, Pathology, and the MR Inst.)

    1991-09-01

    High-resolution real-time ultrasonography (US) and MR imaging, using both spin-echo (SE) and gradient-echo (GE) sequences, were performed prospectively in 14 patients with solitary osteocartilaginous exostoses to assess cartilage cap thickness and bursa formation. Results were compared to surgical and histopathologic findings in all cases. Both US and MR imaging were useful in evaluating exostotic cartilage cap thickness, which is supposed to be the most reliable sign of malignant transformation. Hyaline cartilage matrix had distinctive features in US and MR imaging caused by its specific histologic composition. The formation of bursae over the protruding exostoses, which results in pain and clinically could raise the suspicion of growth and malignant transformation, was demonstrated best using GE sequences. MR imaging was thus superior to US in the detection of bursa formation. (orig.).

  18. The masked educator-innovative simulation in an Australian undergraduate Medical Sonography and Medical Imaging program.

    Science.gov (United States)

    Reid-Searl, Kerry; Bowman, Anita; McAllister, Margaret; Cowling, Cynthia; Spuur, Kelly

    2014-12-01

    Clinical learning experiences for sonography and medical imaging students can sometimes involve the practice of technical procedures with less of a focus on developing communication skills with patients. Whilst patient-based simulation scenarios have been widely reported in other health education programmes, there is a paucity of research in sonography and medical imaging. The aim of this study was to explore the effectiveness of Mask-Ed™ (KRS Simulation) in the learning and teaching of clinical communication skills to undergraduate medical sonography and medical imaging students. Mask-Ed™ (KRS Simulation) is a simulation technique where the educator is hidden behind wearable realistic silicone body props including masks. Focus group interviews were conducted with 11 undergraduate medical sonography and medical imaging students at CQUniversity, Australia. The number of participants was limited to the size of the cohort of students enrolled in the course. Prior to these interviews participants were engaged in learning activities that featured the use of the Mask-Ed™ (KRS Simulation) method. Thematic analysis was employed to explore how the introduction of Mask-Ed™ (KRS Simulation) contributed to students' learning in relation to clinical communication skills. Key themes included: benefits of interacting with someone real rather than another student, learning made fun, awareness of empathy, therapeutic communication skills, engaged problem solving and purposeful reflection. Mask-Ed™ (KRS Simulation) combined with interactive sessions with an expert facilitator, contributed positively to students' learning in relation to clinical communication skills. Participants believed that interacting with someone real, as in the Mask-Ed characters was beneficial. In addition to the learning being described as fun, participants gained an awareness of empathy, therapeutic communication skills, engaged problem solving and purposeful reflection.

  19. Four-dimensional real-time sonographically guided cauterization of the umbilical cord in a case of twin-twin transfusion syndrome.

    Science.gov (United States)

    Timor-Tritsch, Ilan E; Rebarber, Andrei; MacKenzie, Andrew; Caglione, Christopher F; Young, Bruce K

    2003-07-01

    In the past decade, three-dimensional (3D) sonographic technology has matured from a static imaging modality to near-real-time imaging. One of the more notable improvements in this technology has been the speed with which the imaged volume is acquired and displayed. This has enabled the birth of the near-real-time or four-dimensional (4D) sonographic concept. Using the 4D feature of the current 3D sonography machines allows us to follow moving structures, such as fetal motion, in almost real time. Shortly after the emergence of 3D and 4D technology as a clinical imaging tool, its use in guiding needles into structures was explored by other investigators. We present a case in which we used the 4D feature of our sonographic equipment to follow the course and motion of an instrument inserted into the uterus to occlude the umbilical cord of a fetus in a case of twin-twin transfusion syndrome.

  20. About a New Type of Fuse Based on the Controllable Fusing Effect

    Directory of Open Access Journals (Sweden)

    PLESCA, A.

    2009-06-01

    Full Text Available Fuses are among the best known of electrical devices and there are an extremely large number in use throughout the world. Beside of the advantageous features, the nowadays fuses have certain drawbacks. Therefore, a new type of fuse based on controllable fusing concept is proposed and a study as regards the total clearing time is done. The new concept has been validated through many experimental tests at different current values. The new type of fuse based on controllable fusing concept can be integrated within an overcurrent protection system especially to protect power semiconductors where the Joule integral criterion is better satisfied.

  1. Not all ultrasounds are created equal: general sonography versus musculoskeletal sonography in the detection of rotator cuff tears

    Science.gov (United States)

    Cole, Brandi; Twibill, Kristen; Lam, Patrick; Hackett, Lisa

    2016-01-01

    Background This cross-sectional analytic diagnostic accuracy study was designed to compare the accuracy of ultrasound performed by general sonographers in local radiology practices with ultrasound performed by an experienced musculoskeletal sonographer for the detection of rotator cuff tears. Methods In total, 238 patients undergoing arthroscopy who had previously had an ultrasound performed by both a general sonographer and a specialist musculoskeletal sonographer made up the study cohort. Accuracy of diagnosis was compared with the findings at arthroscopy. Results When analyzed as all tears versus no tears, musculoskeletal sonography had an accuracy of 97%, a sensitivity of 97% and a specificity of 95%, whereas general sonography had an accuracy of 91%, a sensitivity of 91% and a specificity of 86%. When the partial tears were split with those ≥ 50% thickness in the tear group and those tear group, musculoskeletal sonography had an accuracy of 97%, a sensitivity of 97% and a specificity of 100% and general sonography had an accuracy of 85%, a sensitivity of 84% and a specificity of 87%. Conclusions Ultrasound in the hands of an experienced musculoskeletal sonographer is highly accurate for the diagnosis of rotator cuff tears. General sonography has improved subsequent to earlier studies but remains inferior to an ultrasound performed by a musculoskeletal sonographer. PMID:27660657

  2. 3-D sonography for diagnosis of disk dislocation of the temporomandibular joint compared with MRI.

    Science.gov (United States)

    Landes, Constantin A; Goral, Wojciech A; Sader, Robert; Mack, Martin G

    2006-05-01

    This study determines the value of three-dimensional (3-D) sonography for the assessment of disk dislocation of the temporomandibular joint (TMJ). Sixty-eight patients (i.e.,136 TMJ) with clinical dysfunction were examined by 272 sonographic 3-D scans. An 8- to 12.5-MHz transducer, angulated by step-motor, was used after picking a volume box on 2-D scan; magnetic resonance imaging followed immediately. Every TMJ was scrutinized in closed- and open-mouth position for normal or dislocated disk position. Fifty-three patients had complete data sets, i.e., 106 TMJ, 212 examinations. Sonographic examination took 5 min, with 74% specificity (62% closed-mouth; 85% open-mouth); sensitivity 53% (62/43%); accuracy 70% (62/77%); positive predictive value 49% (57/41%); and negative predictive value 77% (67/86%). This study encourages more research on the diagnostic capacity of 3-D TMJ sonography, with the advantage of multidimensional joint visualization. Although fair in specificity and negative predictive value, sensitivity and accuracy may ameliorate with future higher-sound frequency, real-time 3-D viewing and automated image analysis.

  3. Iterative Bayesian Estimation of Travel Times on Urban Arterials: Fusing Loop Detector and Probe Vehicle Data.

    Science.gov (United States)

    Liu, Kai; Cui, Meng-Ying; Cao, Peng; Wang, Jiang-Bo

    2016-01-01

    On urban arterials, travel time estimation is challenging especially from various data sources. Typically, fusing loop detector data and probe vehicle data to estimate travel time is a troublesome issue while considering the data issue of uncertain, imprecise and even conflicting. In this paper, we propose an improved data fusing methodology for link travel time estimation. Link travel times are simultaneously pre-estimated using loop detector data and probe vehicle data, based on which Bayesian fusion is then applied to fuse the estimated travel times. Next, Iterative Bayesian estimation is proposed to improve Bayesian fusion by incorporating two strategies: 1) substitution strategy which replaces the lower accurate travel time estimation from one sensor with the current fused travel time; and 2) specially-designed conditions for convergence which restrict the estimated travel time in a reasonable range. The estimation results show that, the proposed method outperforms probe vehicle data based method, loop detector based method and single Bayesian fusion, and the mean absolute percentage error is reduced to 4.8%. Additionally, iterative Bayesian estimation performs better for lighter traffic flows when the variability of travel time is practically higher than other periods.

  4. 21 CFR 872.2050 - Dental sonography device.

    Science.gov (United States)

    2010-04-01

    ... § 872.9. (b) Dental sonography device for interpretation and diagnosis—(1) Identification. A dental sonography device for interpretation and diagnosis is an electrically powered device, intended to interpret temporomandibular joint sounds for the diagnosis of temporomandibular joint disorders and associated orofacial pain...

  5. Sonography as an initial study in patients with suspected ureteral stone

    International Nuclear Information System (INIS)

    Lee, Jae Gue; Lim, Joo Won; Ko, Young Tae; Lee, Dong Ho; Lee, Hye Won; Oh, Joo Hyeong; Yoon, Yup; Lee, Sun Ju

    1999-01-01

    To evaluate the usefulness of sonography as an initial study in patients with suspected ureteral stone. We have undertaken a prospective study for 106 patients with suspected ureteral stone during 15 months. All the patients subsequently underwent urography at a mean interval of 1.8 days after the abdominopelvic sonography. We had only a clinical impression at the sonography and didn't refer to the other study such as KUB. We observed the degree of hydronephrosis using a grading system by Ellenbogen et aland location and size of stone. Seventy four patients had ureteral stone disease. The sonographic findings of these 74 patients showed a stone with hydronephrosis in 61 patients, a stone without hydronephrosis in 9, only hydronephrosis without stone in 2, and unremarkable finding in 2. In 3 of the remaining 32 patients, sonography showed hydronephrosis without stone. Locations of stone were 9 patients of ureteropelvic junction(UPJ), 19 of proximal ureter, 30 of distal ureter, and 16 of ureterovesical junction(UVJ). The sensitivity of sonography for stone was 95% and the specificity was 100%. When a ureteral stone was present, ipsilateral hydronephrosis was detected in 85% of cases on sonography. When only hydronephrosis without stone was detected on sonography, a ureteral stone was diagnosed in 2(40%) of 5 patients. Mean discrepancy of stone size between sonography and KUB was 3.1mm and stone size on sonography was larger. Grade of hydronephrosis between sonography and urography was the same in 32(59%) of 54 patients, whose stones were not expelled until urography after sonography. Sonography could be used as an initial study in patients with suspected ureteral stone.

  6. SINA: A test system for proximity fuses

    Science.gov (United States)

    Ruizenaar, M. G. A.

    1989-04-01

    SINA, a signal generator that can be used for testing proximity fuses, is described. The circuitry of proximity fuses is presented; the output signal of the RF circuit results from a mixing of the emitted signal and received signal that is Doppler shifted in frequency by the relative motion of the fuse with respect to the reflecting target of surface. With SINA, digitized and stored target and clutter signals (previously measured) can be transformed to Doppler signals, for example during a real flight. SINA can be used for testing fuse circuitry, for example in the verification of results of computer simulations of the low frequency Doppler signal processing. The software of SINA and its use are explained.

  7. The cardiac sonography workforce in New Zealand

    Science.gov (United States)

    White, Steve; Poppe, Katrina; Whalley, Gillian

    2015-01-01

    Abstract Introduction: The aim of this paper is to investigate the cardiac sonography workforce characteristics and registration requirements in New Zealand (NZ), with a comparison to similar workforces internationally. Methods: The Survey of Clinical Echocardiography in New Zealand 2 (SCANZ2) audit was performed in December 2010. All of NZ's public‐funded District Health Board (DHB) centers providing echocardiography services responded to questions relating to staff, equipment, procedure types and patient statistics. The Medical Radiation Technologists Board (MRTB), Clinical Physiologists Registration Board (CPRB) and Australian Sonographers Association Registry (ASAR) websites were reviewed in March 2012 for registered sonographers with a cardiac scope of practice. The cardiac sonography workforces in Australia, the UK, the USA and Canada were investigated for comparison. Results: There are 84 cardiac sonographers (60.3 full‐time equivalent) working in DHBs: 71% from a cardiac technical background; 40% have post‐graduate qualifications; a further 17% are undertaking post‐graduate qualifications; and 59 cardiac sonographers have registration with professional bodies in NZ and/or Australia. Cardiac sonographers in NZ do not undergo compulsory registration, but other sonographers in NZ have compulsory registration with the MRTB. Sonographers are predominantly not licensed internationally. Discussion: Disparity exists between registration of cardiac and non‐cardiac sonographers in NZ. Many cardiac sonographers have voluntary registration but few are registered with the MRTB. Reasons for this include professional alignment, educational qualifications and representation. International trends show increased pressure from governments and professional bodies to regulate sonographers. Conclusion: This study provides a snapshot of the cardiac sonography workforce in NZ for the first time. PMID:28191178

  8. Real-time systems

    OpenAIRE

    Badr, Salah M.; Bruztman, Donald P.; Nelson, Michael L.; Byrnes, Ronald Benton

    1992-01-01

    This paper presents an introduction to the basic issues involved in real-time systems. Both real-time operating sys and real-time programming languages are explored. Concurrent programming and process synchronization and communication are also discussed. The real-time requirements of the Naval Postgraduate School Autonomous Under Vehicle (AUV) are then examined. Autonomous underwater vehicle (AUV), hard real-time system, real-time operating system, real-time programming language, real-time sy...

  9. Effectiveness of sonography assisted minimal invasive plate osteosynthesis (MIPO) compare with fluoroscope assisted in femoral shaft fracture: A cadaveric study.

    Science.gov (United States)

    Saengsin, Jirawat; Vaseenon, Tanawat; Pattamapaspong, Nuttaya; Kritsaneephaiboon, Apipop

    2017-08-01

    A minimal invasive plate osteosynthesis (MIPO) has an advantage of biological soft tissue preservation that consists of preserving bony blood supply, fracture hematoma and less soft tissue damage which leads to decreasing of infection rate and rapid bone healing. However, the radiation exposure is still a disadvantage of this technique. A sonography that provides dynamic real time imaging may be used as an alternative technique for assisting MIPO. The aim of this study was to compare the effectiveness of MIPO in femoral shaft fracture between the sonography assisted and the fluoroscopy assisted. Twenty-eight cadaveric limbs were subjected to create femoral shaft fracture. Then, sonography assisted reduction with temporary external fixation and MIPO were performed. Images of the sonography and the fluoroscopy were recorded including before reduction, after reduction and after MIPO in order to identify fracture displacements in anteroposterior and mediolateral directions. Moreover, the anterior and posterior distances from edge of the bone to the plate were measured to confirm plate position. The effectiveness of this technique was defined as the proper plate position and acceptable alignment after fixation. All distances from the sonography and the fluoroscopy were also analyzed and compared using Pearson correlation and Bland-Altman method to assess the agreements between two tests. All of the subjects were met the criteria for acceptable alignment. We found only three femoral shaft fracture (11%) operated with MIPO by sonography assisted that showed slipped plate off femoral bones. According to Pearson correlation, there were good to excellent agreements in term of measuring fracture displacement before (Pearson Correlation >0.7) and after reduction (Pearson Correlation >0.7) between these two tests. There was moderate agreement regarding to evaluation of plate position (Pearson Correlation 03.-0.7). When we compared two methods of measurement using Bland

  10. Follow-up Sonography after Sonoguided Renal Biopsy

    International Nuclear Information System (INIS)

    Kim, Hyung Soo; Park, Cheol Min; Cha, In Ho

    1996-01-01

    To assess ultrasonographic findings and clinical significance after renal biopsy. 174 cases of post-biopsy sonography were studied retrospectively. We classified post-biopsy hematoma on the basis of their size as small (thickness less than 1 cm, length less than 3cm), medium (thickness less than 1cm, length greater than 3 cm), large (thickness greater than 1 cm, length greater than 3 cm). We also compared bleeding parameters (prothrombin time, partial thromboplastin time) and renal function in both cases which had hematoma or not. Total 33 hematomas were found (19%). Small hematoma was observed in 14 cases, medium hematoma in 16 cases, large hematoma in 3 cases. Severe complications requiring prompt therapy occurred in 1 case(0.6%). In 6 cases hematocrit fell by more than 4%, all of these hematomas were observed on US. Severe complications after sonoguided renal biopsy were rare. There was poor correlation between prebiopsybleeding parameter, renal function and post-biopsy hematomas. And sonography is considered as adequate method for follow up of post-biopsy hematoma

  11. Real-Time Ultrasound/MRI Fusion for Suprasacral Parallel Shift Approach to Lumbosacral Plexus Blockade and Analysis of Injectate Spread

    DEFF Research Database (Denmark)

    Strid, Jennie Maria Christin; Pedersen, Erik Morre; Al-Karradi, Sinan Naseer Hussain

    2017-01-01

    Fused real-time ultrasound and magnetic resonance imaging (MRI) may be used to improve the accuracy of advanced image guided procedures. However, its use in regional anesthesia is practically nonexistent. In this randomized controlled crossover trial, we aim to explore effectiveness, procedure-re...

  12. Transcranial Duplex Sonography Predicts Outcome following an Intracerebral Hemorrhage.

    Science.gov (United States)

    Camps-Renom, P; Méndez, J; Granell, E; Casoni, F; Prats-Sánchez, L; Martínez-Domeño, A; Guisado-Alonso, D; Martí-Fàbregas, J; Delgado-Mederos, R

    2017-08-01

    Several radiologic features such as hematoma volume are related to poor outcome following an intracerebral hemorrhage and can be measured with transcranial duplex sonography. We sought to determine the prognostic value of transcranial duplex sonography in patients with intracerebral hemorrhage. We conducted a prospective study of patients diagnosed with spontaneous intracerebral hemorrhage. Transcranial duplex sonography examinations were performed within 2 hours of baseline CT, and we recorded the following variables: hematoma volume, midline shift, third ventricle and lateral ventricle diameters, and the pulsatility index in both MCAs. We correlated these data with the CT scans and assessed the prognostic value of the transcranial duplex sonography measurements. We assessed early neurologic deterioration during hospitalization and mortality at 1-month follow-up. We included 35 patients with a mean age of 72.2 ± 12.8 years. Median baseline hematoma volume was 9.85 mL (interquartile range, 2.74-68.29 mL). We found good agreement and excellent correlation between transcranial duplex sonography and CT when measuring hematoma volume ( r = 0.791; P duplex sonography measurements showed that hematoma volume was an independent predictor of early neurologic deterioration (OR, 1.078; 95% CI, 1.023-1.135) and mortality (OR, 1.089; 95% CI, 1.020-1.160). A second regression analysis with CT variables also demonstrated that hematoma volume was associated with early neurologic deterioration and mortality. When we compared the rating operation curves of both models, their predictive power was similar. Transcranial duplex sonography showed an excellent correlation with CT in assessing hematoma volume and midline shift in patients with intracerebral hemorrhage. Hematoma volume measured with transcranial duplex sonography was an independent predictor of poor outcome. © 2017 by American Journal of Neuroradiology.

  13. Gastrointestinal tract sonography in fetuses and children

    Energy Technology Data Exchange (ETDEWEB)

    Couture, Alain; Baud, Catherine; Ferran, Jean Louis; Saguintaah, Magali; Veyrac, Corinne [Hopital Arnaud de Villeneuve, 34 - Montpellier (France). Service de Radiologie Pediatrique

    2008-07-01

    Sonography of the gastrointestinal tract in fetuses, neonates and children entails no known biological risk, permits serial scanning and can provide information unobtainable with any other imaging modality. In experienced hands it can be used as the initial imaging technique in a number of gastrointestinal diseases and conditions. This book provides a comprehensive account of the current state of the art regarding sonography in this context. An introductory chapter compares the merits of sonography and magnetic resonance imaging of the fetal gastrointestinal tract. Subsequent chapters focus on the technique, pitfalls and findings in a wide variety of applications, including antropyloric diseases, bowel obstruction, bowel wall thickening, colitis, appendicitis, some types of intussusception, abdominal wall and umbilical abnormalities, intraperitoneal tumors, and trauma. In each case the sonographic morphology is considered in depth with the aid of high-quality illustrations. A concluding chapter comprises a quiz based on 15 case reports. Gastrointestinal Tract Sonography in Fetuses and Children will be of value to all with an interest in this field. (orig.)

  14. Transvaginal versus transabdominal sonography in the evaluation of pelvic pathology

    International Nuclear Information System (INIS)

    Qureshi, I.H.; Ullah, H.; Akram, M.H.; Ashfaq, S.; Nayyar, S.

    2004-01-01

    Objective: To find the accuracy of sonographic information provided by transvaginal sonography (TVS) in pelvic pathology as compared to transabdominal sonography (TAS). Materials and Methods: Hundred patients were included in the study from a total of 212 referred for pelvic sonography. Two radiologists independently performed transabdominal and transvaginal sonography of these patients. An independent observer compared the findings. TVS was graded as superior, equal or inferior to TAS depending on the score assigned by them. Results: TVS was considered superior in 63%, equal in 27% and inferior in 10% of the cases as compared to transabdominal sonography. It was graded inferior to TAS in cases with large pelvic masses and superior in majority of cases of ovarian follicle monitoring, polycystic ovaries, endometrial carcinoma and suspected ectopic pregnancy. Cases in which both techniques were considered equal included patients with no abnormal finding, some pelvic masses and advanced pelvic inflammatory disease. Conclusion: Transvagival sonography is superior to transabdominal sonography in most cases of pelvic pathology. However, TAS should still be the initial sonographic technique for routine evaluation of the female pelvis followed by TVS if indicated. In cases of ovarian follicle monitoring, suspected polycystic ovaries, endometrial pathology and suspected ectopic pregnancy, TVS may be used as the initial sonographic technique and can even replace TAS. (author)

  15. TractorEYE: Vision-based Real-time Detection for Autonomous Vehicles in Agriculture

    DEFF Research Database (Denmark)

    Christiansen, Peter

    ) using a smaller memory footprint and 7.3-times faster processing. Low memory footprint and fast processing makes DeepAnomaly suitable for real-time applications running on an embedded GPU. FieldSAFE is a multi-modal dataset for detection of static and moving obstacles in agriculture. The dataset...... (four for rgb camera, one for thermal camera and one for a Multi-beam lidar) and fuse detection information in a common format using either 3D positions or Inverse Sensor Models. A GPU powered computational platform is able to run detection algorithms online. For the rgb camera, a deep learning...... algorithm is proposed DeepAnomaly to perform real-time anomaly detection of distant, heavy occluded and unknown obstacles in agriculture. DeepAnomaly is - compared to a state-of-the-art object detector Faster R-CNN - for an agricultural use-case able to detect humans better and at longer ranges (45-90m...

  16. Targeted hepatic sonography during clinic visits for detection of fatty liver in overweight children: a pilot study.

    Science.gov (United States)

    Perito, Emily R; Tsai, Patrika M; Hawley, Sarah; Lustig, Robert H; Feldstein, Vickie A

    2013-04-01

    The purpose of this study was to assess the feasibility and utility of targeted hepatic sonography to evaluate for hepatic steatosis during a subspecialty clinic visit. In this pilot study, we performed targeted hepatic sonography on 25 overweight children aged 7 to 17 years consecutively seen in a pediatric obesity clinic. Long-axis images of the right lobe of the liver and a split-screen image of liver and spleen were taken. Images were interpreted in real time by the radiologist and shown to the family. Demographics, clinical measurements, and laboratory parameters were also collected from the specialty clinic visit on the same day. Sonography required a median of 4 minutes during the visit (interquartile range, 3-5 minutes). All consented patients completed the study. The median alanine aminotransferase (ALT) level was 23 U/L in those with no steatosis (n = 14), 26 U/L with mild steatosis (n = 6), and 41 U/L with moderate/marked steatosis (n = 5). Children with ALT levels of 25 to 50 U/L had very variable sonographic measures of hepatic steatosis. When the participants were categorized by the overall degree of fatty liver, hepatic steatosis was significantly associated with the aspartate aminotransferase level (P = .028), ALT level (P = .003), and diastolic blood pressure (P = .05) but did not correlate with age, sex, Latino race, or insulin resistance. Targeted hepatic sonography added information not apparent from routine ALT screening and provided immediate feedback to clinicians and families about the effect of obesity on end organs. This examination could be a feasible, informative addition to screening for children at high risk for nonalcoholic fatty liver disease who are seen in clinics that specialize in obesity.

  17. Focused abdominal sonography for trauma (FAST) in blunt paediatric abdominal trauma

    International Nuclear Information System (INIS)

    Faruque, A. V.; Qazi, S. H.; Khan, M. A. M.

    2013-01-01

    Objective: To evaluate the role of focussed abdominal sonography for trauma in blunt paediatric abdominal trauma patients, and to see if the role of computed tomography scan could be limited to only those cases in which sonography was positive. Methods: The retrospective study covered 10 years, from January 1, 2000 to December 31, 2009, and was conducted at the Department of Radiology and Department of Emergency Medicine, Aga Khan University Hospital, Karachi. It comprised cases of 174 children from birth to 14 years who had presented with blunt abdominal trauma and had focussed abdominal sonography for trauma done at the hospital. The findings were correlated with computed tomography scan of the abdomen and clinical follow-up. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of focussed abdominal sonography for trauma were calculated for blunt abdominal trauma. SPSS 17 was used for statistical analysis. Results: Of the total 174 cases, 31 (17.81%) were later confirmed by abdominal scan. Of these 31 children, sonography had been positive in 29 (93.54%) children. In 21 (67.74%) of the 31 children, sonography had been true positive; 8 (25%) (8/31) were false positive; and 2 (6%) (2/31) were false negative. There were 6 (19.3%) children in which sonography was positive and converted to laparotomy. There was no significant difference on account of gender (p>0.356). Focussed abdominal sonography for trauma in the study had sensitivity of 91%, specificity of 95%, positive predictive value of 73%, and negative predictive value of 73% with accuracy of 94%. All patients who had negative sonography were discharged later, and had no complication on clinical follow-up. Conclusions: Focussed abdominal sonography for trauma is a fairly reliable mode to assess blunt abdominal trauma in children. It is a useful tool to pick high-grade solid and hollow viscous injury. The results suggest that the role of computed tomography scan can be

  18. Duplex sonography of the near-surface leg veins

    International Nuclear Information System (INIS)

    Mendoza, E.

    2007-01-01

    The book contains the following contributions: The ultrasonograph, selection of the ultrasonic transducer, anatomy of the near-surface vein system, physiology of the near-surface vein system, varicose status classification, systematics of the duplex sonography of near-surface leg veins, provocational maneuver for the duplex sonographic varicose diagnostics, exploration of vena saphena parva, perforans veins, side branches, phlebitis, sonography for varicose therapy, postsurgical sonography, deep leg veins, examination of near-surface leg veins for the pathology of the deep vein system, differential diagnostic clarification of leg oedema from the phlebologic-lymphological view, diagnostic side features along the near-surface leg veins

  19. Clinical experience with contrast infusion sonography as an Essure confirmation test.

    Science.gov (United States)

    Connor, Viviane F

    2011-06-01

    The purpose of this study was to assess the clinical experience, including the feasibility, safety, compliance, and efficacy, of contrast infusion sonography as an Essure (Conceptus Inc, Mountain View, CA) confirmation test. A retrospective chart review and telephone survey were conducted at an academic multispecialty group. The study participants were women with Essure intervention who underwent contrast infusion sonography, transvaginal sonography, and hysterosalpingography as Essure confirmation tests. The main outcome measures included the feasibility, safety, compliance, and efficacy of contrast infusion sonography as a first-line Essure confirmation test. A total of 118 women had successful bilateral Essure placement. Of the 63 who consented to contrast infusion sonography, 53 (84.1%) had proper bilateral placement and tubal occlusion and were encouraged to rely on Essure. Four were suspected of having unilateral tubal patency; hysterosalpingography in 2 confirmed bilateral tubal occlusion, and 2 were noncompliant with second-line hysterosalpingography. Three patients suspected of having unsatisfactory or uncertain placement on initial transvaginal sonography were encouraged to undergo hysterosalpingography in lieu of contrast infusion sonography, which confirmed unsatisfactory placement in 2 and proper placement and occlusion in 1. Three contrast infusion sonographic procedures could not be completed because of technical issues; therefore, contrast infusion sonography was feasible in 95.2% of the patients (60 of 63). No notable adverse events occurred. Only 17 patients were noncompliant with any confirmation test, yielding an overall compliance rate of 86% (101 of 118). No pregnancies occurred during 669 woman-months of follow-up. The average reimbursement for contrast infusion sonography was US$251.78. Preliminary clinical data suggest that contrast infusion sonography is a feasible, safe, and accurate Essure confirmation test, which is well accepted by

  20. Contrast infusion sonography in the post-Essure setting.

    Science.gov (United States)

    Connor, Viviane

    2008-01-01

    To compare contrast infusion sonogram (CIS) to hysterosalpingogram (HSG) for use as a 3-month confirmation test after Essure. Pilot study (Canadian Task Force classification II-2). Healthy women in an academic multispecialty group. Seventeen women desiring permanent sterilization who had had successful bilateral Essure placement within 12 weeks. Contrast infusion sonography was performed and immediately followed by an HSG at the same appointment, between 1 and 12 weeks after Essure placement. To determine how well microinsert location and tubal status can be assessed with CIS, an adaptation of hysterosalpingo contrast sonography (HyCoSy), when compared with sequential HSG. Tubal occlusion rate within 4 to 8 weeks after Essure placement was also noted. All microinserts were readily identified with ultrasound, and location was accurately determined. In all patients (100%) with at least 1 tube patent on HSG, patency was also demonstrated on CIS by visualizing real-time flow in the tube or the presence of dye in the cul-de-sac or adnexa. There were no significant adverse events, and pain ratings were similar for both tests. The majority (88%) of patients felt strongly that they would prefer to have a 3-month confirmation test performed in the gynecologist's office rather than an unfamiliar radiologic facility. Tubal occlusion was noted on both CIS and HSG in 82% of patients before 12 weeks. Based on this pilot study with a small sample, CIS, an adaptation of HyCoSy, has comparable accuracy to HSG in the post-Essure setting. The safety, convenience, and comfort of an in-office test using ultrasound and a non-iodine-based dye would be a welcome alternative to HSG. There was also a high rate of bilateral fallopian tube occlusion noted on HSG at 4 weeks after Essure.

  1. Optimization of Region of Interest Drawing for Quantitative Analysis: Differentiation Between Benign and Malignant Breast Lesions on Contrast-Enhanced Sonography.

    Science.gov (United States)

    Nakata, Norio; Ohta, Tomoyuki; Nishioka, Makiko; Takeyama, Hiroshi; Toriumi, Yasuo; Kato, Kumiko; Nogi, Hiroko; Kamio, Makiko; Fukuda, Kunihiko

    2015-11-01

    This study was performed to evaluate the diagnostic utility of quantitative analysis of benign and malignant breast lesions using contrast-enhanced sonography. Contrast-enhanced sonography using the perflubutane-based contrast agent Sonazoid (Daiichi Sankyo, Tokyo, Japan) was performed in 94 pathologically proven palpable breast mass lesions, which could be depicted with B-mode sonography. Quantitative analyses using the time-intensity curve on contrast-enhanced sonography were performed in 5 region of interest (ROI) types (manually traced ROI and circular ROIs of 5, 10, 15, and 20 mm in diameter). The peak signal intensity, initial slope, time to peak, positive enhancement integral, and wash-out ratio were investigated in each ROI. There were significant differences between benign and malignant lesions in the time to peak (P benign and malignant lesions in the time to peak (P benign and malignant breast lesions. © 2015 by the American Institute of Ultrasound in Medicine.

  2. Sonography in the diagnosis of acute appendicitis

    Directory of Open Access Journals (Sweden)

    Ahmad Ryazi

    2003-09-01

    Full Text Available Graded compressive sonography may be useful as an adjuvant in the diagnosis of acute appendicitis. To determine the role of sonography in the differential diagnosis of acute appendicitis, preappendectomy sonographic data of 164 consecutive cases in Fatemeh-Zahra Teaching Hospital were evaluated. Of 113 (68.9% patients who had acute appendicitis in histopathology, 64 (56.6% cases had preoperative sonographic diagnosis of acute appendicitis. Of 51 patients who had normal appendices, 40 (78.4% cases had normal appendices in sonographic evaluations. Sensitivity, specificity and accuracy of sonography for acute appendicitis were 56.7%, 78.4% and 0.63, respectively. The positive and negative predictive values were 85.3% and 44.49% respectively. As a result, sonographic evaluation is an additional diagnostic tool in acute appendicitis.

  3. Focused abdominal sonography for trauma (FAST) in blunt paediatric abdominal trauma.

    Science.gov (United States)

    Faruque, Ahmad Vaqas; Qazi, Saqib Hamid; Khan, Muhammad Arif Mateen; Akhtar, Wassem; Majeed, Amina

    2013-03-01

    To evaluate the role of focussed abdominal sonography for trauma in blunt paediatric abdominal trauma patients, and to see if the role of computed tomography scan could be limited to only those cases in which sonography was positive. The retrospective study covered 10 years, from January 1,2000 to December 31,2009, and was conducted at the Department of Radiology and Department of Emergency Medicine, Aga Khan University Hospital, Karachi. It comprised cases of 174 children from birth to 14 years who had presented with blunt abdominal trauma and had focussed abdominal sonography for trauma done at the hospital. The findings were correlated with computed tomography scan of the abdomen and clinical follow-up. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of focussed abdominal sonography for trauma were calculated for blunt abdominal trauma. SPSS 17 was used for statistical analysis. Of the total 174 cases, 31 (17.81%) were later confirmed by abdominal scan. Of these 31 children, sonography had been positive in 29 (93.54%) children. In 21 (67.74%) of the 31 children, sonograpy had been true positive; 8 (25%) (8/31) were false positive; and 2 (6%) (2/31) were false negative. There were 6 (19.3%) children in which sonography was positive and converted to laparotomy. There was no significant difference on account of gender (p>0.356). Focussed abdominal sonography for trauma in the study had sensitivity of 91%, specificity of 95%, positive predictive value of 73%, and negative predictive value of 73% with accuracy of 94%. All patients who had negative sonography were discharged later, and had no complication on clinical follow-up. Focussed abdominal sonography for trauma is a fairly reliable mode to assess blunt abdominal trauma in children. It is a useful tool to pick high-grade solid and hollow viscous injury. The results suggest that the role of computed tomography scan can be limited to those cases in which focussed

  4. Fused Reality for Enhanced Flight Test Capabilities

    Science.gov (United States)

    Bachelder, Ed; Klyde, David

    2011-01-01

    The feasibility of using Fused Reality-based simulation technology to enhance flight test capabilities has been investigated. In terms of relevancy to piloted evaluation, there remains no substitute for actual flight tests, even when considering the fidelity and effectiveness of modern ground-based simulators. In addition to real-world cueing (vestibular, visual, aural, environmental, etc.), flight tests provide subtle but key intangibles that cannot be duplicated in a ground-based simulator. There is, however, a cost to be paid for the benefits of flight in terms of budget, mission complexity, and safety, including the need for ground and control-room personnel, additional aircraft, etc. A Fused Reality(tm) (FR) Flight system was developed that allows a virtual environment to be integrated with the test aircraft so that tasks such as aerial refueling, formation flying, or approach and landing can be accomplished without additional aircraft resources or the risk of operating in close proximity to the ground or other aircraft. Furthermore, the dynamic motions of the simulated objects can be directly correlated with the responses of the test aircraft. The FR Flight system will allow real-time observation of, and manual interaction with, the cockpit environment that serves as a frame for the virtual out-the-window scene.

  5. Transvaginal sonography of acute pelvic inflammatory disease

    International Nuclear Information System (INIS)

    Choi, Jin Soo; Kim, Young Hwa; Shin, Hyung Chul; Han, Gun Soo; Kim, Il Young

    1999-01-01

    To determine the value of transvaginal sonography in evaluating women with acute pelvic inflammatory disease (PID). Transvaginal sonography was performed in 25 patients with clinically suggested PID during recent 36 months. The sonographic findings of fallopian tubes and ovaries were analyzed and correlated with pathological findings of 2 fallopian tubes and 19 ovaries in 16 patients who had operations. The correct diagnosis of acute PID was made in 20/25 (80%) by transvaginal sonography. the abnormal sonographic findings of the fallopian tube include tubal thickening or dilatation with internal echo. The sensitivity, specificity, and accuracy for tubal abnormality were 88%, 96%, and 86% , respectively. Ovarian changes were seen on TVS in 14/19 (73%), which include multiple follicular enlargement in 5, tubo-ovarian complex in 9 (tubo-ovarian adhesion in 3, tubo-ovarian abscess in 6). At surgery, the ovay was not involved in all three women who showed tubo-ovarian adhesion on TVS. Among 6 women who showed tubo-ovarian abscess on TVS, tubo-ovarian abscess was confirmed in 3 and the remaining 3 had ovarian cysts. Trandvaginal sonography, a facilitative and accurate modality, is highly sensitive in detecting the abnormality of the tube and useful in differentiating the tubo-ovarian complex in patients with acute PID.

  6. Seizing the Future: How Ohio's Career-Technical Education Programs Fuse Academic Rigor and Real-World Experiences to Prepare Students for College and Careers

    Science.gov (United States)

    Guarino, Heidi; Yoder, Shaun

    2015-01-01

    "Seizing the Future: How Ohio's Career and Technical Education Programs Fuse Academic Rigor and Real-World Experiences to Prepare Students for College and Work," demonstrates Ohio's progress in developing strong policies for career and technical education (CTE) programs to promote rigor, including college- and career-ready graduation…

  7. Rotator cuff ruptures of the shoulder joint, sonography - arthrography

    International Nuclear Information System (INIS)

    Triebel, H.J.; Wening, V.; Witte, G.; Hamburg Univ.

    1986-01-01

    47 patients suspected of rutpure of the rotator cuff were sonographed and arthrographed. Rupture of the rotator cuff was diagnosed in 12 cases, both diagnostic methods yielding the same result. In 29 patients sonography and arthrography did not reveal any abnormal findings. Six ruptures evident in sonography were not confirmed by arthrography and were considered false positive. Direct pointers towards rupture of the cuff would be: echoless defects, cuff cannot be visualised fully or in part and irregularities of movement during dynamic examination. Echoless 'cystic' areas in the periarticular soft parts must be considered an indirect pointer. Echorich focal findings in the echopoor cuff represent a differential diagnostic problem and we cannot give a final assessment as yet. Shoulder sonography is justified as a screening method in suspicion of rotator cuff rupture before initiating arthrography. If sonography reveals no abnormal findings, shoulder arthrography need not be performed. (orig.) [de

  8. Assessment of cutaneous radiation fibrosis by 20 MHz-sonography

    International Nuclear Information System (INIS)

    Gottloeber, P.; Braun-Falco, B.; Plewig, G.; Kerscher, M.; Peter, R.U.; Nadeshina, N.

    1996-01-01

    Radiation fibrosis is the cardinal symptom of the chronicle stage of the cutaneous radiation syndrome. The degree of cutaneous fibrosis can clinically be estimated by palpation. High-frequency 20 MHz-sonography is an established, noninvasive procedure, which renders an exact determination of skin thickness and additionally densitometry is possible. We investigated 15 survivors of the Chernobyl accident in 1986, who developed symptoms of the chronic stage of the cutaneous radiation syndrome. We determined skin thickness and echogenicity of skin areas clinically suggestive of radiation fibrosis before, during and after treatment. 20 MHz-sonography showed a distinct enlargement of the echorich corium and a reduction of the subcutaneous fatty tissue in comparison with the unaffected, contralateral skin, here demonstrating typical features of radiation fibrosis, namely dermal fibrosis and reactive pseudoatrophy and fatty tissue. The histology presented an increase and swelling of the collagen fibers and atypical fibroblastic cells. The patients received treatment with low-dose interferon y (Polyfcron R , 3 x 50μg s.C., three times per week) up to 30 months. A marked reduction of skin thickness and echogenicity reaching nearly normal values could be observed. We conclude that 20 MHz-sonography is an easy to apply, noninvasive, well established procedure to quantify cutaneous radiation fibrosis and to assess therapeutic outcome

  9. The accuracy of transvaginal sonography to detect endometriosis cyst

    Science.gov (United States)

    Diantika, M.; Gunardi, E. R.

    2017-08-01

    Endometriosis is common in women of reproductive age. Late diagnosis is still the main concern. Currently, noninvasive diagnostic testing, such as transvaginal sonography, is recommended. The aim of the current study was to evaluate the accuracy of transvaginal sonography in diagnosing endometrial cysts in patients in Cipto Mangunkusumo Hospital, Jakarta, Indonesia. This diagnostic study was carried out at Cipto Mangunkusumo Hospital between January 2014 and June 2015. Outpatients suspected have an endometrial cyst based on the patient history and a clinical examination was recruited. The patients were then evaluated using transvaginal sonography by an experienced sonologist, according to the research protocol. The gold standard test was a histological finding in the removed surgical mass. Ninety-eight patients were analyzed. An endometrial cyst was confirmed by histology in 85 patients (87%). The accuracy, sensitivity, specificity, positive predictive value and negative predictive value of transvaginal sonography was established to be 85% (a range of 71-99%), 93%, 77%, 96%, and 63%, respectively. A significantly higher area under the curve was identified using transvaginal sonogpraphy compared to that achieved with a clinical examination alone (85% versus 79%). Transvaginal sonography was useful in diagnosing endometrial cysts in outpatients and is recommended in daily clinical practice.

  10. Real Time Revisited

    Science.gov (United States)

    Allen, Phillip G.

    1985-12-01

    The call for abolishing photo reconnaissance in favor of real time is once more being heard. Ten years ago the same cries were being heard with the introduction of the Charge Coupled Device (CCD). The real time system problems that existed then and stopped real time proliferation have not been solved. The lack of an organized program by either DoD or industry has hampered any efforts to solve the problems, and as such, very little has happened in real time in the last ten years. Real time is not a replacement for photo, just as photo is not a replacement for infra-red or radar. Operational real time sensors can be designed only after their role has been defined and improvements made to the weak links in the system. Plodding ahead on a real time reconnaissance suite without benefit of evaluation of utility will allow this same paper to be used ten years from now.

  11. Mammography and breast sonography in transsexual women

    International Nuclear Information System (INIS)

    Weyers, S.; Villeirs, G.; Vanherreweghe, E.; Verstraelen, H.; Monstrey, S.; Van den Broecke, R.; Gerris, J.

    2010-01-01

    Data on the necessity of performing screening mammographies in transsexual women are lacking. The main objective of this study was to assess the possibility to perform mammography and breast sonography in transsexual women. Fifty Dutch-speaking transsexual women were interviewed about the following: attitude towards mammography and breast sonography, importance attributed to and satisfaction with breast appearance, opinion about the necessity of breast check-up, expectations regarding discomfort during the exams and knowledge about the breast surgery. A fasting blood sample, clinical breast exam, mammography and breast sonography were performed. At mammography the following parameters were noted: density, technical quality, location of the prostheses, presence of any abnormalities and painfulness. At sonography the following parameters were recorded: density, presence of cysts, visualisation of retro-areolar ducts or any abnormalities. Twenty-three percent of patients are not aware of the type of breast implants and 79% do not know their position to the pectoral muscles. Patient satisfaction with the appearance of their breasts was rather high (7.94 on a scale of 0-10). Mean expected and experienced pain from mammography was low (4.37 and 2.00 respectively). There was no statistically significant difference in expected pain between those who already had mammography and those who did not. There was a significant positive correlation between the expected and the experienced pain. Mammography and breast sonography were technically feasible and no gross anomalies were detected. Since both exams were judged as nearly painless, 98% of transsexual women intended to come back if they would be invited. Since breast cancer risk in transsexual women is largely unknown and breast exams are very well accepted, breast screening habits in this population should not differ from those of biological women.

  12. Mammography and breast sonography in transsexual women

    Energy Technology Data Exchange (ETDEWEB)

    Weyers, S., E-mail: steven.weyers@ugent.b [Department of Gynecology, Ghent University Hospital, De Pintelaan 185, B-9000 Ghent (Belgium); Villeirs, G.; Vanherreweghe, E. [Department of Radiology, Ghent University Hospital, Ghent (Belgium); Verstraelen, H. [Department of Gynecology, Ghent University Hospital, De Pintelaan 185, B-9000 Ghent (Belgium); Monstrey, S. [Department of Plastic Surgery, Ghent University Hospital, Ghent (Belgium); Van den Broecke, R.; Gerris, J. [Department of Gynecology, Ghent University Hospital, De Pintelaan 185, B-9000 Ghent (Belgium)

    2010-06-15

    Data on the necessity of performing screening mammographies in transsexual women are lacking. The main objective of this study was to assess the possibility to perform mammography and breast sonography in transsexual women. Fifty Dutch-speaking transsexual women were interviewed about the following: attitude towards mammography and breast sonography, importance attributed to and satisfaction with breast appearance, opinion about the necessity of breast check-up, expectations regarding discomfort during the exams and knowledge about the breast surgery. A fasting blood sample, clinical breast exam, mammography and breast sonography were performed. At mammography the following parameters were noted: density, technical quality, location of the prostheses, presence of any abnormalities and painfulness. At sonography the following parameters were recorded: density, presence of cysts, visualisation of retro-areolar ducts or any abnormalities. Twenty-three percent of patients are not aware of the type of breast implants and 79% do not know their position to the pectoral muscles. Patient satisfaction with the appearance of their breasts was rather high (7.94 on a scale of 0-10). Mean expected and experienced pain from mammography was low (4.37 and 2.00 respectively). There was no statistically significant difference in expected pain between those who already had mammography and those who did not. There was a significant positive correlation between the expected and the experienced pain. Mammography and breast sonography were technically feasible and no gross anomalies were detected. Since both exams were judged as nearly painless, 98% of transsexual women intended to come back if they would be invited. Since breast cancer risk in transsexual women is largely unknown and breast exams are very well accepted, breast screening habits in this population should not differ from those of biological women.

  13. The value of computer tomography and sonography in the investigation of the pancreas

    International Nuclear Information System (INIS)

    Lackner, K.; Frommhold, H.; Grauthoff, H.; Moedder, U.; Heuser, L.; Braun, G.; Buurman, R.; Scherer, K.; Hamburg Univ.; Koeln Univ.

    1980-01-01

    Three hundred and five patients were examined by computer tomography and sonography. In 117 patients no abnormalities were found in the pancreas. The accuracy of computer tomography was 87%, of sonography 85%. In 41 patients the presence of a carcinoma of the pancreas was confirmed histologically. In this group the sensitivity of computer tomography was 83%, of sonography 85%. Thirty-four patients suffered from acute pancreatitis. In this group sensitivity of the two methods was equal at 79%. 113 patients had changes of chronic pancreatitis. Sensitivity of computer tomography was 84%, of sonography 70%. Computer tomography is better at demonstrating calcification in the pancreas. Atrophy of the pancreas cannot be diagnosed by sonography. (orig.) [de

  14. Real-Time fusion of visual images and laser data images for safe navigation in outdoor environments

    OpenAIRE

    García-Alegre Sánchez, María C.; Martín, David; Guinea García-Alegre, Domingo M.; Guinea Díaz, Domingo

    2011-01-01

    [EN]In recent years, two dimensional laser range finders mounted on vehicles is becoming a fruitful solution to achieve safety and environment recognition requirements (Keicher & Seufert, 2000), (Stentz et al., 2002), (DARPA, 2007). They provide real-time accurate range measurements in large angular fields at a fixed height above the ground plane, and enable robots and vehicles to perform more confidently a variety of tasks by fusing images from visual cameras with range data (...

  15. Sonography in the 29th Olympic and Paralympic Games: a retrospective analysis.

    Science.gov (United States)

    He, Wen; Xiang, Dong-ying; Dai, Jian-ping

    2011-01-01

    The purpose of this study was to evaluate the application of sonography at the polyclinic of the Olympic/Paralympic village during the Olympic/Paralympic Games. We retrospectively reviewed 759 consecutive patients who underwent sonography at the ultrasound division of the polyclinic in the Olympic/Paralympic village from July 20, 2008, to September 20, 2008. Prevalence of emergency sonography after sports injury and non-sports-related urgent conditions during the games was analyzed. The benefit of sonographic services in large sporting events was discussed. There were 759 patients (484 athletes, 101 coaches, 88 team officials, and 86 volunteers; 462 men and 297 women) in the ultrasound division at the polyclinic. The indications for sonography included abdominal pain (315 cases, 41.50%), muskuloskeletal disorders (228 cases, 30.04%), gynecology related (104 cases, 13.70%), cardiac conditions (49 cases, 6.46%), small parts (29 cases, 3.82%), and vascular problems (34 cases, 4.48%). The rates of positive findings on sonography were 46.03% in the abdomen, 70.17% in musculoskeleton, 41.34% in gynecology, 10.20% in the heart, 75.86% in small parts, and 38.24% in vessels, respectively. Sonography plays an important role in the medical services at the polyclinic in the Olympic/Paralympic village. The benefits of sonography in such large sporting events are accuracy, fast result, portability, and noninvasiveness. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Dihydropyridine-fused and pyridine-fused coumarins: Reduction on a glassy carbon electrode in dimethylformamide

    International Nuclear Information System (INIS)

    Nuñez-Vergara, Luis J.; Pardo-Jiménez, V.; Barrientos, C.; Olea-Azar, C.A.; Navarrete-Encina, P.A.; Squella, J.A.

    2012-01-01

    In this study, two series of dihydropyridine-fused and pyridine-fused coumarins were synthesised and electrochemically characterised in aprotic medium. In both series, the most easily reducible groups were the endocyclic carbonyl groups. The electrochemical mechanism for both types of compounds is strongly dependent on the experimental time-scale. Cyclic voltammetric (CV) reduction on a glassy carbon electrode (GCE) of the endocyclic carbonyl group of dihydropyridine-fused coumarins involves an ECEC mechanism with two electron transfer steps that are coupled with chemical reactions to produce the corresponding hemiacetal derivative. In the case of pyridine-fused coumarins, CV reduction of the endocyclic carbonyl group involves an EEC mechanism. ESR studies revealed the presence of a stabilised intermediate only for the pyridine-fused derivatives. Our theoretical study showed a spin density map of radical species delocalised mainly within the coumarin ring, indicating the reduction of the endocyclic carbonyl group. In the case of the dihydropyridine-fused derivatives, the mildly acid hydrogen of the dihydropyridine ring destabilises the radical via a father–son type reaction.

  17. Role of sonography in the diagnosis of Echinococcus alveolaris

    Energy Technology Data Exchange (ETDEWEB)

    Maier, W.

    1983-02-01

    Abdominal sonography and computed tomography were performed in eleven patients with operatively and histologically proven Echinococcus alveolaris of the liver and the detailed appearances were compared. Sonography is a useful screening method in the assessment of E. alveolaris, but its previous importance is being gradually superseded by computed tomography, which is capable of providing more detailed information in the diagnosis of Echinococcus infestation.

  18. SimFuse: A Novel Fusion Simulator for RNA Sequencing (RNA-Seq Data

    Directory of Open Access Journals (Sweden)

    Yuxiang Tan

    2015-01-01

    Full Text Available The performance evaluation of fusion detection algorithms from high-throughput sequencing data crucially relies on the availability of data with known positive and negative cases of gene rearrangements. The use of simulated data circumvents some shortcomings of real data by generation of an unlimited number of true and false positive events, and the consequent robust estimation of accuracy measures, such as precision and recall. Although a few simulated fusion datasets from RNA Sequencing (RNA-Seq are available, they are of limited sample size. This makes it difficult to systematically evaluate the performance of RNA-Seq based fusion-detection algorithms. Here, we present SimFuse to address this problem. SimFuse utilizes real sequencing data as the fusions’ background to closely approximate the distribution of reads from a real sequencing library and uses a reference genome as the template from which to simulate fusions’ supporting reads. To assess the supporting read-specific performance, SimFuse generates multiple datasets with various numbers of fusion supporting reads. Compared to an extant simulated dataset, SimFuse gives users control over the supporting read features and the sample size of the simulated library, based on which the performance metrics needed for the validation and comparison of alternative fusion-detection algorithms can be rigorously estimated.

  19. Real Time 3D Facial Movement Tracking Using a Monocular Camera

    Directory of Open Access Journals (Sweden)

    Yanchao Dong

    2016-07-01

    Full Text Available The paper proposes a robust framework for 3D facial movement tracking in real time using a monocular camera. It is designed to estimate the 3D face pose and local facial animation such as eyelid movement and mouth movement. The framework firstly utilizes the Discriminative Shape Regression method to locate the facial feature points on the 2D image and fuses the 2D data with a 3D face model using Extended Kalman Filter to yield 3D facial movement information. An alternating optimizing strategy is adopted to fit to different persons automatically. Experiments show that the proposed framework could track the 3D facial movement across various poses and illumination conditions. Given the real face scale the framework could track the eyelid with an error of 1 mm and mouth with an error of 2 mm. The tracking result is reliable for expression analysis or mental state inference.

  20. Laser-assisted selective fusing of thermal sprayed Ni-based self-fluxing alloys by using high-power diode lasers

    Science.gov (United States)

    Chun, Eun-Joon; Kim, Min-Su; Nishikawa, Hiroshi; Park, Changkyoo; Suh, Jeong

    2018-03-01

    Fusing treatment of Ni-based self-fluxing alloys (Metco-16C and 1276F) was performed using high-power diode lasers to control the temperature of the substrate's surface in real time. The effects of the fusing treatment temperature on the microstructural change and hardness distribution were also investigated. For Metco-16C and 1276F, the macrostructural inhomogeneity (voids) within the thermal sprayed layer decreased considerably as the fusing temperature increased. For both self-fluxing alloys, the optimal temperature for fusing was approximately 1423 K (for Metco-16C) and 1373 K (for 1276F), both of which are within the solid state temperature range; these temperatures maximize the alloy hardness together with the macrostructural homogeneity. In this temperature range, the microstructure consists of a lamellar-structured matrix phase with fine (diode laser system.

  1. Clinical applications of imaging reconstruction by virtual sonography

    International Nuclear Information System (INIS)

    Mori, Akihiro; Oohashi, Noritsugu; Maruyama, Takako; Tatebe, Hideharu; Fushimi, Nobutoshi; Asano, Takayuki; Inoue, Hiroshi; Okuno, Masataka

    2008-01-01

    One of the pitfalls in managing multiple liver tumors is the difficulty in identifying individual tumors on ultrasonography. Computed tomography (CT)-assisted virtual sonography has been shown to improve sonographic diagnosis, however it requires additional equipment and software. We have developed a simple reconstruction method of virtual sonography (SRVS). We reconstructed SRVS mimicking ultrasonographic images, utilizing a workstation software attached to a multi-detector row CT system without any additional program. We have performed SRVS in 32 patients with 41 liver tumors that could hardly be identify on ultrasonography. SRVS assisted the identification of malignant form non-pathologic ones and thereby contributed to the appropriate clinical strategy including radiofrequency ablation (RFA) (18 tumors), liver biopsy (2 tumors), other therapies (4 tumors) and follow-up (17 tumors). We have developed virtual sonography using conventional CT software. SRVS seems useful in the clinical practice in managing liver tumors. (author)

  2. New developments in imaging: Sonography, cine-CT, MRI

    International Nuclear Information System (INIS)

    Otto, R.J.; Higgins, C.B.

    1987-01-01

    The book can be conveniently subdivided into three sections: the first on magnetic resonance imaging the second on cine-computed tomography and the third on advances in ultrasound (US). The MR imaging section includes two chapters: the first on indications for MR in abdominal disease (a cookbook layout of indications for MR imaging versus CT) and the second on MR imaging of the heart. There are also chapters on MR imaging and US in the pelvis, contrast agent principles, and a chapter on imaging renal tumors. The third section, on US, contains chapters on the liver and gastrointenstinal disease, interventional US sonography during neurosurgery, state-of-the-art echocardiography. Doppler flow imaging, contrast media for sonography, endometrial sonography, and high-resolution US in the first trimester. The final chapter is presented as a scientific paper rather than as a chapter in a book and has no illustrations

  3. High resolution compression elastography and color doppler sonography in characterization of breast fibroadenoma.

    Science.gov (United States)

    Rjosk-Dendorfer, D; Reu, S; Deak, Z; Hetterich, H; Kolben, T; Reiser, M; Clevert, D A

    2014-01-01

    To evaluate the use of color Doppler sonography and free hand sonoelastography in the assessment of breast fibroadenomas according to their size and shape. From December 2012 to March 2013 women with 16 solid breast masses, classified as BI-RADS category 3 or 4 were examined with B-mode ultrasound, sonoelastography and color Doppler sonography. Lesions were subdivided according to their shape in round, ovoid or macrolobulated and according to their size (fibroadenomas in B-mode sonography could be shown (p = 0.91) and also comparison of Tsukuba-scores and size of masses revealed no significant differences (p = 1.0). Sizes of fibroadenomas ≥2 cm were significantly associated with an increased vascularization of the lesions (p = 0.04) and a macrolobulated appearance in B-mode sonography (p = 0.04). The combination of color Doppler sonography and sonoelastography in addition to B-mode sonography leads to an increased accuracy in distinguishing benign from malignant breast masses and to an improvement in characterization of fibroadenomas independent of their shape or size.

  4. Sonography-guided hydrostatic reduction of ileocolic intussusception in children: analysis of failure and success in consecutive patients presenting timely to the hospital.

    Science.gov (United States)

    Menke, Jan; Kahl, Fritz

    2015-03-01

    In children with ileocolic intussusception sonography is increasingly being used for diagnosis, whereas fluoroscopy is frequently used for guiding non-invasive reduction. This study assessed the success rate of radiation-free sonography-guided hydrostatic reduction in children with ileocolic intussusception, using novel well-defined success rate indices. All children were evaluated who presented from 2005 to 2013 to the local university hospital with ileocolic intussusception. The patients were treated with sonography-guided hydrostatic reduction unless primary surgery was clinically indicated. The according success rate was determined by indices of Bekdash et al. They represent the ratio of persistently successful non-surgical reductions versus four different denominators, depending on including/excluding cases with primary surgery and including/excluding cases requiring bowel resection/intervention. Fifty-six consecutive patients were included (age, 3 months to 7.8 years). About 80% of the patients presented until 24 h and 20% until 48 h after the onset of symptoms. Seven patients underwent primary surgery, with bowel resection required in three cases. Hydrostatic reduction was attempted in 49 patients, being permanently successful in 41 cases (selective reduction rate 41/49 = 83.7%; crude reduction rate 41/56 = 73.2%). The remaining eight patients underwent secondary surgery, with just two patients not requiring surgical bowel resection/intervention (corrected selective reduction rate 41/43 = 95.3%). The composite reduction rate was 87.2% (successful/feasible reductions, 41/47). Radiation-free sonography-guided hydrostatic reduction has a good success rate in children with ileocolic intussusception. It may be particularly valuable in centers that are already experienced with using sonography for the diagnosis.

  5. Diagnostic accuracy of sonography for pleural effusion: systematic review

    Directory of Open Access Journals (Sweden)

    Alexandre Grimberg

    Full Text Available CONTEXT AND OBJECTIVE: The initial method for evaluating the presence of pleural effusion was chest radiography. Isolated studies have shown that sonography has greater accuracy than radiography for this diagnosis; however, no systematic reviews on this matter are available in the literature. Thus, the aim of this study was to evaluate the accuracy of sonography in detecting pleural effusion, by means of a systematic review of the literature. DESIGN AND SETTING: This was a systematic review with meta-analysis on accuracy studies. This study was conducted in the Department of Diagnostic Imaging and in the Brazilian Cochrane Center, Discipline of Emergency Medicine and Evidence-Based Medicine, Department of Medicine, Universidade Federal de São Paulo (Unifesp, São Paulo, Brazil. METHOD: The following databases were searched: Cochrane Library, Medline, Web of Science, Embase and Literatura Latino-Americana e do Caribe em Ciências da Saúde (Lilacs. The references of relevant studies were also screened for additional citations of interest. Studies in which the accuracy of sonography for detecting pleural effusion was tested, with an acceptable reference standard (computed tomography or thoracic drainage, were included. RESULTS: Four studies were included. All of them showed that sonography had high sensitivity, specificity and accuracy for detecting pleural effusions. The mean sensitivity was 93% (95% confidence interval, CI: 89% to 96%, and specificity was 96% (95% CI: 95% to 98%. CONCLUSIONS: In different populations and clinical settings, sonography showed consistently high sensitivity, specificity and accuracy for detecting fluid in the pleural space.

  6. Radio controlled detonators and sequential real time blast applications

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, T.; Laboz, J.M. [Delta Caps International, Nice (France)

    1995-12-31

    Among the numerous technical evolutions in the blasting environment the authors are going to describe below the concept of electronic detonator sequenced by radio waves, and also its numerous applications. Three major technologies are used in the initiation environment: fused-initiated detonators; electric detonators; and non-electric detonators. The last two technologies were made available under multiple variants. Two major innovations are going to substantially change the way traditional detonators operate: pyrotechnic delays are replaced by electronic delays (greater accuracy); and triggering orders, passing through a cable, is now replaced by radio-waves transmission (possibility to do real time delay pattern). Such a new product provided all the features offered by current detonators, but also allows mastering specific cases that were difficult to control with the current technology, such as: vibration control; underground blast; and building demolition.

  7. Sonography for diagnosis of benign and malignant tumors of the nose and paranasal sinuses.

    Science.gov (United States)

    Liu, Jun-jie; Gao, Yong; Wu, Ya-Fei; Zhu, Shang-Yong

    2014-09-01

    The purpose of this study was to demonstrate the reliability of sonography for diagnosis of nose and paranasal sinus tumors. Ninety-six consecutive patients with tumors underwent sonography and computed tomography (CT) before surgical treatment. Tumor detectability and imaging findings were evaluated independently and then compared with pathologic findings. Of 96 tumors, 75 were detected by sonography, for a detectability rate of 78.1%; 93 tumors were detected by CT, for a detectability rate of 96.9%. By comparison, sonography showed a trend toward higher detectability of nasal vestibular tumors than CT (87.5% for sonography versus 50.0% for CT) and small lumps on the wing of the nose (78.8% for sonography versus 33.3% for CT). Among the sonographic features, boundary, shape, internal echo, calcification, bone invasion, vascular pattern, and cervical lymph node metastasis all had significantly positive correlations with malignancy (P benign and malignant tumors of the nose and paranasal sinuses. Consequently, sonography has high value for diagnosis of benign and malignant tumors of the nose and paranasal sinuses, especially for nasal vestibular tumors and small lumps on the wing of the nose. © 2014 by the American Institute of Ultrasound in Medicine.

  8. Real-time vibration-based structural damage detection using one-dimensional convolutional neural networks

    Science.gov (United States)

    Abdeljaber, Osama; Avci, Onur; Kiranyaz, Serkan; Gabbouj, Moncef; Inman, Daniel J.

    2017-02-01

    Structural health monitoring (SHM) and vibration-based structural damage detection have been a continuous interest for civil, mechanical and aerospace engineers over the decades. Early and meticulous damage detection has always been one of the principal objectives of SHM applications. The performance of a classical damage detection system predominantly depends on the choice of the features and the classifier. While the fixed and hand-crafted features may either be a sub-optimal choice for a particular structure or fail to achieve the same level of performance on another structure, they usually require a large computation power which may hinder their usage for real-time structural damage detection. This paper presents a novel, fast and accurate structural damage detection system using 1D Convolutional Neural Networks (CNNs) that has an inherent adaptive design to fuse both feature extraction and classification blocks into a single and compact learning body. The proposed method performs vibration-based damage detection and localization of the damage in real-time. The advantage of this approach is its ability to extract optimal damage-sensitive features automatically from the raw acceleration signals. Large-scale experiments conducted on a grandstand simulator revealed an outstanding performance and verified the computational efficiency of the proposed real-time damage detection method.

  9. Architecture for an integrated real-time air combat and sensor network simulation

    Science.gov (United States)

    Criswell, Evans A.; Rushing, John; Lin, Hong; Graves, Sara

    2007-04-01

    An architecture for an integrated air combat and sensor network simulation is presented. The architecture integrates two components: a parallel real-time sensor fusion and target tracking simulation, and an air combat simulation. By integrating these two simulations, it becomes possible to experiment with scenarios in which one or both sides in a battle have very large numbers of primitive passive sensors, and to assess the likely effects of those sensors on the outcome of the battle. Modern Air Power is a real-time theater-level air combat simulation that is currently being used as a part of the USAF Air and Space Basic Course (ASBC). The simulation includes a variety of scenarios from the Vietnam war to the present day, and also includes several hypothetical future scenarios. Modern Air Power includes a scenario editor, an order of battle editor, and full AI customization features that make it possible to quickly construct scenarios for any conflict of interest. The scenario editor makes it possible to place a wide variety of sensors including both high fidelity sensors such as radars, and primitive passive sensors that provide only very limited information. The parallel real-time sensor network simulation is capable of handling very large numbers of sensors on a computing cluster of modest size. It can fuse information provided by disparate sensors to detect and track targets, and produce target tracks.

  10. Differential diagnosis of persistent neonatal jaundice: Role of sonography and scintigraphy

    International Nuclear Information System (INIS)

    Lee, Sun Wha; Ko, Young Tae; Lim, Jae Hoon

    1993-01-01

    The most common causes of conjugated hyperbilirubinaemia after the first or second week of life are neonatal hepatitis and biliary atresia. Since these entities represent variable expressions of same pathologic process and have similar clinical, biochemical, and histologic features, differential diagnosis is extremely difficult. We prospectively studies 28 jaundiced infants by sonography and hepatobiliary scintigraphy. Final diagnoses included 12 biliary atresia and 16 neonatal hepatitis. Visualization of a normal sized common bile duct or gallbladder was compatible with the diagnosis of neonatal hepatitis. Non-visualized or atrophic gallbladder on sonography coupled with non-visualization of bowel activity on scintigraphy was highly suggestive of biliary atresia. We believe that sonography plays a valuable role in the initial evaluation of the infants with persistent neonatal jaundice. The combined use of sonography and hepatobiliary scintigraphy provides the most valuable information in suspected biliary atresia for prompt surgical treatment

  11. Sonography in the postoperative evaluation of laparoscopic inguinal hernia repair.

    Science.gov (United States)

    Furtschegger, A; Sandbichler, P; Judmaier, W; Gstir, H; Steiner, E; Egender, G

    1995-09-01

    We evaluated the use of sonography as a means of assessing hernial occlusion and possible postoperative changes such as hematomas or seromas in the inguinal and scrotal regions after 1139 laparoscopic repairs of hernias between August 1992 and November 1994. Changes after laparoscopic hernia repair were found in 307 patients (27%). Hematomas or seromas were seen in 132 patients, protrusion of the prosthetic mesh in 17, mesh infection in two, and small bowel entrapment in an insufficient peritoneal suture in two. Recurrences were diagnosed correctly in six patients, mobile preperitoneal lipomas in five. Sonography is useful in the evaluation of complications after laparoscopic hernia repair, including recurrent hernia. In the absence of symptoms, sonography is not indicated.

  12. Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips.

    Science.gov (United States)

    Schulz-Wendtland, R; Dankerl, P; Dilbat, G; Bani, M; Fasching, P A; Heusinger, K; Lux, M P; Loehberg, C R; Jud, S M; Rauh, C; Bayer, C M; Beckmann, M W; Wachter, D L; Uder, M; Meier-Meitinger, M; Brehm, B

    2015-01-01

    Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography.

  13. Principles and practice of sonography

    International Nuclear Information System (INIS)

    Fleischer, A.C.; James, A.E.

    1987-01-01

    This book is a text of sonographic technique, emphasizing clinical and diagnostic procedures. Ultrasound images and explanatory line drawings are placed side-by-side to facilitate interpretation. This book covers instrumentation and scanning principles, obstetric, gynecologic, abdominal, renal and urologic, pediatric, plus superficial structure sonography

  14. A hierarachical data structure representation for fusing multisensor information

    Energy Technology Data Exchange (ETDEWEB)

    Maren, A.J. [Tennessee Univ., Tullahoma, TN (United States). Space Inst.; Pap, R.M.; Harston, C.T. [Accurate Automation Corp., Chattanooga, TN (United States)

    1989-12-31

    A major problem with MultiSensor Information Fusion (MSIF) is establishing the level of processing at which information should be fused. Current methodologies, whether based on fusion at the data element, segment/feature, or symbolic levels, are each inadequate for robust MSIF. Data-element fusion has problems with coregistration. Attempts to fuse information using the features of segmented data relies on a Presumed similarity between the segmentation characteristics of each data stream. Symbolic-level fusion requires too much advance processing (including object identification) to be useful. MSIF systems need to operate in real-time, must perform fusion using a variety of sensor types, and should be effective across a wide range of operating conditions or deployment environments. We address this problem through developing a new representation level which facilitates matching and information fusion. The Hierarchical Data Structure (HDS) representation, created using a multilayer, cooperative/competitive neural network, meets this need. The HDS is an intermediate representation between the raw or smoothed data stream and symbolic interpretation of the data. it represents the structural organization of the data. Fused HDSs will incorporate information from multiple sensors. Their knowledge-rich structure aids top-down scene interpretation via both model matching and knowledge-based region interpretation.

  15. A hierarachical data structure representation for fusing multisensor information

    Energy Technology Data Exchange (ETDEWEB)

    Maren, A.J. (Tennessee Univ., Tullahoma, TN (United States). Space Inst.); Pap, R.M.; Harston, C.T. (Accurate Automation Corp., Chattanooga, TN (United States))

    1989-01-01

    A major problem with MultiSensor Information Fusion (MSIF) is establishing the level of processing at which information should be fused. Current methodologies, whether based on fusion at the data element, segment/feature, or symbolic levels, are each inadequate for robust MSIF. Data-element fusion has problems with coregistration. Attempts to fuse information using the features of segmented data relies on a Presumed similarity between the segmentation characteristics of each data stream. Symbolic-level fusion requires too much advance processing (including object identification) to be useful. MSIF systems need to operate in real-time, must perform fusion using a variety of sensor types, and should be effective across a wide range of operating conditions or deployment environments. We address this problem through developing a new representation level which facilitates matching and information fusion. The Hierarchical Data Structure (HDS) representation, created using a multilayer, cooperative/competitive neural network, meets this need. The HDS is an intermediate representation between the raw or smoothed data stream and symbolic interpretation of the data. it represents the structural organization of the data. Fused HDSs will incorporate information from multiple sensors. Their knowledge-rich structure aids top-down scene interpretation via both model matching and knowledge-based region interpretation.

  16. Reliability and precision of stress sonography of the ulnar collateral ligament.

    Science.gov (United States)

    Bica, David; Armen, Joseph; Kulas, Anthony S; Youngs, Kevin; Womack, Zachary

    2015-03-01

    Musculoskeletal sonography has emerged as an additional diagnostic tool that can be used to assess medial elbow pain and laxity in overhead throwers. It provides a dynamic, rapid, and noninvasive modality in the evaluation of ligamentous structural integrity. Many studies have demonstrated the utility of dynamic sonography for medial elbow and ulnar collateral ligament (UCL) integrity. However, evaluating the reliabilityand precision of these measurements is critical if sonography is ultimately used as a clinical diagnostic tool. The purpose of this study was to evaluate the reliability and precision of stress sonography applied to the medial elbow. We conducted a cross-sectional study during the 2011 baseball off-season. Eighteen National Collegiate Athletic Association Division I pitchers were enrolled, and 36 elbows were studied. Using sonography, the medial elbow was assessed, and measurements of the UCL length and ulnohumeral joint gapping were performed twice under two conditions (unloaded and loaded) and bilaterally. Intraclass correlation coefficients (0.72-0.94) and standard errors of measurements (0.3-0.9 mm) for UCL length and ulnohumeral joint gapping were good to excellent. Mean differences between unloaded and loaded conditions for the dominant arms were 1.3 mm (gapping; P < .001) and 1.4 mm (UCL length; P < .001). Medial elbow stress sonography is a reliable and precise method for detecting changes in ulnohumeral joint gapping and UCL lengthening. Ultimately, this method may provide clinicians valuable information regarding the medial elbow's response to valgus loading and may help guide treatment options. © 2015 by the American Institute of Ultrasound in Medicine.

  17. Real-Time Large Scale 3d Reconstruction by Fusing Kinect and Imu Data

    Science.gov (United States)

    Huai, J.; Zhang, Y.; Yilmaz, A.

    2015-08-01

    Kinect-style RGB-D cameras have been used to build large scale dense 3D maps for indoor environments. These maps can serve many purposes such as robot navigation, and augmented reality. However, to generate dense 3D maps of large scale environments is still very challenging. In this paper, we present a mapping system for 3D reconstruction that fuses measurements from a Kinect and an inertial measurement unit (IMU) to estimate motion. Our major achievements include: (i) Large scale consistent 3D reconstruction is realized by volume shifting and loop closure; (ii) The coarse-to-fine iterative closest point (ICP) algorithm, the SIFT odometry, and IMU odometry are combined to robustly and precisely estimate pose. In particular, ICP runs routinely to track the Kinect motion. If ICP fails in planar areas, the SIFT odometry provides incremental motion estimate. If both ICP and the SIFT odometry fail, e.g., upon abrupt motion or inadequate features, the incremental motion is estimated by the IMU. Additionally, the IMU also observes the roll and pitch angles which can reduce long-term drift of the sensor assembly. In experiments on a consumer laptop, our system estimates motion at 8Hz on average while integrating color images to the local map and saving volumes of meshes concurrently. Moreover, it is immune to tracking failures, and has smaller drift than the state-of-the-art systems in large scale reconstruction.

  18. Sonography and electrodiagnosis in carpal tunnel syndrome diagnosis, an analysis of the literature

    International Nuclear Information System (INIS)

    Seror, P.

    2008-01-01

    We present a review of the international literature concerning sonography for the diagnosis of carpal tunnel syndrome (CTS). Analysis of the results and comparison with electrodiagnostic data provide a sensible albeit personal view on the relevance of sonography and whether it competes or is complementary to electrodiagnosis (EDX). Although EDX is considered as the gold standard for CTS diagnosis, one author chose surgical results to define CTS. The normal and threshold mean values for sonography are particularly variable from one study to another. The standard deviation (S.D.), when compared to mean values, makes normal and abnormal data overlap considerably and produces many false negatives when the specificity is high, and many false positives when the sensitivity is high. In fact, sonography is non-interpretable in only 10 to 15% of the population, and it affirms the median nerve lesion at the wrist in 55% of cases when EDX does it in more than 90% with common tests. Further more the specificity of sonography leads to a false positive diagnosis in 1 case out of 5 versus 1 out of 40 with EDX. The main conclusion is that there is no competition but rather a complementarity between sonography and EDX: sonography is certainly an efficient imaging technique but cannot replace proper EDX performed for upper limb paresthesiae. Namely, sonography can answer only one out of the 8 questions a complete EDX answer: Are sonographic images compatible with a median nerve lesion at the wrist? The answer to this solely question can be obtain with a partial EDX using a single conduction test (motor or sensitive), then duration and cost will be comparable to sonography but will be both more sensitive and specific. Finally, one must kept in mind that the final aim of all examinations in CTS is to determine the cause(s) of upper limb paresthesiae, not simply if there is a median nerve lesion at wrist or not

  19. Afferent loop syndrome: Role of sonography and CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Ho; Lim, Jae Hoon; Ko, Young Tae [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1992-03-15

    Afferent loop syndrome(ALS) is caused by obstruction of the afferent loop after subtotal gastrectomy with Billroth II gastrojejunostomy. Prompt diagnosis of ALS is important as perforation of the loop occurs. The aim of study is to ascertain the sonography and CT to diagnose ALS. We describe the radiologic findings in ten patients with ALS. The cause of ALS, established at surgery, included cancer recurrence (n=4), internal hernia (n=4), marginal ulcer (n=1), and development of cancer at the anastomosis site (n=1). Abdominal X-ray and sonography were performed in all cases, upper GI series in five cases and computed tomography in two cases. The dilated afferent loop was detected in only two cases out often patients in retrospective review of abdominal X-ray. ALS with recurrence of cancer was diagnosed in three cases by upper GI series. Of the cases that had sonography, the afferent loop was seen in the upper abdomen crossing transversely over the midline in all ten patients. The cause of ALS were predicated on the basis of the sonograms in three of the five patients. In two cases of computed tomography, the dilated afferent loop and recurrent cancer at the remnant stomach were seen.Our experience suggests that the diagnosis of afferent syndrome can be made on the basis of the typical anatomic location and shape of the dilated bowel loop in both sonography and computed tomography.

  20. LATENCY DETERMINATION AND COMPENSATION IN REAL-TIME GNSS/INS INTEGRATED NAVIGATION SYSTEMS

    Directory of Open Access Journals (Sweden)

    P. D. Solomon

    2012-09-01

    Full Text Available Unmanned Aerial Vehicle (UAV technology is now commonplace in many defence and civilian environments. However, the high cost of owning and operating a sophisticated UAV has slowed their adoption in many commercial markets. Universities and research groups are actively experimenting with UAVs to further develop the technology, particularly for automated flying operations. The two main UAV platforms used are fixed-wing and helicopter. Helicopter-based UAVs offer many attractive features over fixed-wing UAVs, including vertical take-off, the ability to loiter, and highly dynamic flight. However the control and navigation of helicopters are significantly more demanding than those of fixed-wing UAVs and as such require a high bandwidth real-time Position, Velocity, Attitude (PVA navigation system. In practical Real-Time Navigation Systems (RTNS there are delays in the processing of the GNSS data prior to the fusion of the GNSS data with the INS measurements. This latency must be compensated for otherwise it degrades the solution of the navigation filter. This paper investigates the effect of latency in the arrival time of the GNSS data in a RTNS. Several test drives and flights were conducted with a low-cost RTNS, and compared with a high quality GNSS/INS solution. A technique for the real-time, automated and accurate estimation of the GNSS latency in low-cost systems was developed and tested. The latency estimates were then verified through cross-correlation with the time-stamped measurements from the reference system. A delayed measurement Extended Kalman Filter was then used to allow for the real-time fusing of the delayed measurements, and then a final system developed for on-the-fly measurement and compensation of GNSS latency in a RTNS.

  1. Latency Determination and Compensation in Real-Time Gnss/ins Integrated Navigation Systems

    Science.gov (United States)

    Solomon, P. D.; Wang, J.; Rizos, C.

    2011-09-01

    Unmanned Aerial Vehicle (UAV) technology is now commonplace in many defence and civilian environments. However, the high cost of owning and operating a sophisticated UAV has slowed their adoption in many commercial markets. Universities and research groups are actively experimenting with UAVs to further develop the technology, particularly for automated flying operations. The two main UAV platforms used are fixed-wing and helicopter. Helicopter-based UAVs offer many attractive features over fixed-wing UAVs, including vertical take-off, the ability to loiter, and highly dynamic flight. However the control and navigation of helicopters are significantly more demanding than those of fixed-wing UAVs and as such require a high bandwidth real-time Position, Velocity, Attitude (PVA) navigation system. In practical Real-Time Navigation Systems (RTNS) there are delays in the processing of the GNSS data prior to the fusion of the GNSS data with the INS measurements. This latency must be compensated for otherwise it degrades the solution of the navigation filter. This paper investigates the effect of latency in the arrival time of the GNSS data in a RTNS. Several test drives and flights were conducted with a low-cost RTNS, and compared with a high quality GNSS/INS solution. A technique for the real-time, automated and accurate estimation of the GNSS latency in low-cost systems was developed and tested. The latency estimates were then verified through cross-correlation with the time-stamped measurements from the reference system. A delayed measurement Extended Kalman Filter was then used to allow for the real-time fusing of the delayed measurements, and then a final system developed for on-the-fly measurement and compensation of GNSS latency in a RTNS.

  2. Re-Appraising the Role of Sonography in Pediatric Acute Abdominal Pain

    OpenAIRE

    Lin, Wei-Ching; Lin, Chien-Heng

    2013-01-01

    Objective Most pediatric emergency department (ED) visits are due to acute abdominal pain. Sonography is a reliable technique for differential diagnosis. The objective of this study was to re-appraise the role of sonography in evaluating acute abdominal pain in children. Methods Retrospective chart review of children aged

  3. Transabdominal bowl sonography

    DEFF Research Database (Denmark)

    Wilkens, Rune; Strandberg, Charlotte

    2014-01-01

    This focused review describes the current use and future perspectives regarding transabdominal bowel sonography (TABS). The technique for B-mode and Doppler is described and the use of ultrasound contrast and elastography is discussed. Pathology and subsequent imaging findings are focused on appe...... on appendicitis, diverticulitis, inflammatory bowel diseases and within paediatric conditions along with other common intestinal pathology. In conclusion we find that TABS is a fast, efficient, low-cost and non-ionization imaging technique without any patient discomfort....

  4. Real-time shadows

    CERN Document Server

    Eisemann, Elmar; Assarsson, Ulf; Wimmer, Michael

    2011-01-01

    Important elements of games, movies, and other computer-generated content, shadows are crucial for enhancing realism and providing important visual cues. In recent years, there have been notable improvements in visual quality and speed, making high-quality realistic real-time shadows a reachable goal. Real-Time Shadows is a comprehensive guide to the theory and practice of real-time shadow techniques. It covers a large variety of different effects, including hard, soft, volumetric, and semi-transparent shadows.The book explains the basics as well as many advanced aspects related to the domain

  5. The efficiency of sonography in diagnosing volvulus in neonates with suspected intestinal malrotation.

    Science.gov (United States)

    Zhang, Wenhua; Sun, Hongjun; Luo, Fangqiong

    2017-10-01

    This study is to prospectively evaluate the efficiency of sonography for volvulus diagnosis in neonates with clinically suspected intestinal malrotation.A total of 83 patients with suspected intestinal malrotation who underwent detailed abdominal sonography and upper gastrointestinal contrast study were included. Malrotation was characterized by inversion of the superior mesenteric artery (SMA) and superior mesenteric vein (SMV) in sonographic examination. The "whirlpool sign" of Color Doppler Sonography was recognized as a characteristic for malrotation with volvulus. The degrees of rotation of the SMV winding around SMA were also detected by sonography. Surgery was performed in patients with sonography diagnosed malrotation.A total of 39 patients were sonographically diagnosed as malrotation which was subsequently confirmed by surgery. The sensitivity and positive predictive value of the sonographic diagnosis were both 100% (39/39). The sensitivity, specificity and accuracy of "whirlpool sign" for the detection of midgut volvulus were 95.2% (20/21), 88.9% (16/18), and 92.3% (36/39), respectively. Greater degrees of rotation (equal or greater than 720°) showed higher risk (odds ratio, 5.0; P volvulus may be used as a potential indicator for intestinal necrosis. In addition, sonography can exclude malrotation and may help the diagnosis of other diseases, such as annular pancreas and duodenal atresia.

  6. Malignant and benign diseases of the breast in 41 male patients: mammography, sonography and pathological correlations; Maligne und benigne Erkrankungen der Brust bei 41 maennlichen Patienten: Mammographie und Sonographie mit histopathologischer Korrelation

    Energy Technology Data Exchange (ETDEWEB)

    Partik, B.; Mallek, R.; Pokieser, P.; Wunderbaldinger, P.; Helbich, T.H. [Vienna Univ. (Austria). Klinik fuer Radiodiagnostik; Rudas, M. [Vienna Univ. (Austria). Inst. fuer Klinische Pathologie

    2001-11-01

    Aim: The goal of our study was to evaluate findings in mammography and sonography in male patients with pathohistologically proven diseases of the breast. Material and Methods: Mammographies and sonographies, which were obtained in 41 male patients in a 6-year period, were retrospectively evaluated in accordance with the BI-RADS trademark classification. Results: Histologically 13 carcinomas, 21 gynecomastias, 3 pseudogynecomastias, 2 epithelial inclusion cysts and 2 other benign lesions were diagnosed. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of mammography in differentiation of benign versus malignant disease were 92%, 89%, 80%, 96% and 90%, respectively. Additional sonography did not change these results. However, sonography increased diagnostic confidence in 18.2% (2/11) of suspicious lesions. Conclusion: In our study the invasive ductal carcinoma of male patients was a predominantly lobulated, ill-defined lesion in mammography and sonography. The differentiation of carcinoma to pseudogynecomastia and diffuse or dendritic gynecomastia was securely feasible. However, we could not reliably distinguish between carcinoma and some benign mass lesions. In cases of mammographically diagnosed masses or unclear mammography, additional sonography should be performed to increase the diagnostic confidence. (orig.) [German] Ziel: Die Befunde von Mammographie und Sonographie bei histologisch gesicherten malignen und benignen Mammaerkrankungen maennlicher Patienten zu evaluieren. Material und Methode: Retrospektiv wurden die in einem Zeitraum von 6 Jahren durchgefuehrten Mammographien und Sonographien bei 41 maennlichen Patienten in Anlehnung an die BI-RADS trademark Klassifikation ausgewertet. Resultate: Es wurden 13 Karzinome, 21 Gynaekomastien, 3 Pseudogynaekomastien, 2 Atherome und 2 weitere benigne Laesionen histologisch diagnostiziert. Die Mammographie zeigte in der Differenzierung maligne versus benigne Laesion

  7. Dependable Real-Time Systems

    Science.gov (United States)

    1991-09-30

    0196 or 413 545-0720 PI E-mail Address: krithi@nirvan.cs.umass.edu, stankovic(ocs.umass.edu Grant or Contract Title: Dependable Real - Time Systems Grant...Dependable Real - Time Systems " Grant or Contract Number: N00014-85-k-0398 L " Reporting Period: 1 Oct 87 - 30 Sep 91 , 2. Summary of Accomplishments ’ 2.1 Our...in developing a sound approach to scheduling tasks in complex real - time systems , (2) developed a real-time operating system kernel, a preliminary

  8. LabVIEW Real-Time

    CERN Multimedia

    CERN. Geneva; Flockhart, Ronald Bruce; Seppey, P

    2003-01-01

    With LabVIEW Real-Time, you can choose from a variety of RT Series hardware. Add a real-time data acquisition component into a larger measurement and automation system or create a single stand-alone real-time solution with data acquisition, signal conditioning, motion control, RS-232, GPIB instrumentation, and Ethernet connectivity. With the various hardware options, you can create a system to meet your precise needs today, while the modularity of the system means you can add to the solution as your system requirements grow. If you are interested in Reliable and Deterministic systems for Measurement and Automation, you will profit from this seminar. Agenda: Real-Time Overview LabVIEW RT Hardware Platforms - Linux on PXI Programming with LabVIEW RT Real-Time Operating Systems concepts Timing Applications Data Transfer

  9. Enhancements and Evolution of the Real Time Mission Monitor

    Science.gov (United States)

    Goodman, M.; Blakeslee, R.; Hardin, D.; Hall, J.; He, Y.; Regner, K.

    2008-12-01

    The Real Time Mission Monitor (RTMM) is a visualization and information system that fuses multiple Earth science data sources, to enable real time decision-making for airborne and ground validation experiments. Developed at the National Aeronautics and Space Administration (NASA) Marshall Space Flight Center, RTMM is a situational awareness, decision-support system that integrates satellite imagery, radar, surface and airborne instrument data sets, model output parameters, lightning location observations, aircraft navigation data, soundings, and other applicable Earth science data sets. The integration and delivery of this information is made possible using data acquisition systems, network communication links, network server resources, and visualizations through the Google Earth virtual earth application. RTMM has proven extremely valuable for optimizing individual Earth science airborne field experiments. Flight planners, mission scientists, instrument scientists and program managers alike appreciate the contributions that RTMM makes to their flight projects. RTMM has received numerous plaudits from a wide variety of scientists who used RTMM during recent field campaigns including the 2006 NASA African Monsoon Multidisciplinary Analyses (NAMMA), 2007 Tropical Composition, Cloud, and Climate Coupling (TC4), 2008 Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS) missions, the 2007-2008 NOAA-NASA Aerosonde Hurricane flights and the 2008 Soil Moisture Active-Passive Validation Experiment (SMAP-VEX). Improving and evolving RTMM is a continuous process. RTMM recently integrated the Waypoint Planning Tool, a Java-based application that enables aircraft mission scientists to easily develop a pre-mission flight plan through an interactive point-and-click interface. Individual flight legs are automatically calculated for altitude, latitude, longitude, flight leg distance, cumulative distance, flight leg time, cumulative time, and

  10. Concepts of real time and semi-real time material control

    International Nuclear Information System (INIS)

    Lovett, J.E.

    1975-01-01

    After a brief consideration of the traditional material balance accounting on an MBA basis, this paper explores the basic concepts of real time and semi-real time material control, together with some of the major problems to be solved. Three types of short-term material control are discussed: storage, batch processing, and continuous processing. (DLC)

  11. Real Time Systems

    DEFF Research Database (Denmark)

    Christensen, Knud Smed

    2000-01-01

    Describes fundamentals of parallel programming and a kernel for that. Describes methods for modelling and checking parallel problems. Real time problems.......Describes fundamentals of parallel programming and a kernel for that. Describes methods for modelling and checking parallel problems. Real time problems....

  12. Real time expert systems

    International Nuclear Information System (INIS)

    Asami, Tohru; Hashimoto, Kazuo; Yamamoto, Seiichi

    1992-01-01

    Recently, aiming at the application to the plant control for nuclear reactors and traffic and communication control, the research and the practical use of the expert system suitable to real time processing have become conspicuous. In this report, the condition for the required function to control the object that dynamically changes within a limited time is presented, and the technical difference between the real time expert system developed so as to satisfy it and the expert system of conventional type is explained with the actual examples and from theoretical aspect. The expert system of conventional type has the technical base in the problem-solving equipment originating in STRIPS. The real time expert system is applied to the fields accompanied by surveillance and control, to which conventional expert system is hard to be applied. The requirement for the real time expert system, the example of the real time expert system, and as the techniques of realizing real time processing, the realization of interruption processing, dispersion processing, and the mechanism of maintaining the consistency of knowledge are explained. (K.I.)

  13. The role of sonography in the diagnosis of Echinococcus alveolaris

    International Nuclear Information System (INIS)

    Maier, W.

    1983-01-01

    Abdominal sonography and computed tomography were performed in eleven patients with operatively and histologically proven Echinococcus alveolaris of the liver and the detailed appearances were compared. Sonography is a useful screening method in the assessment of E. alveolaris, but its previous importance is being gradually superseded by computed tomography, which is capable of providing more detailed information in the diagnosis of Echinococcus infestation. (orig.)

  14. Tc-99m DTPA perfusion scintigraphy and color coded duplex sonography in the evaluation of minimal renal allograft perfusion

    International Nuclear Information System (INIS)

    Bair, H.J.; Platsch, G.; Wolf, F.; Guenter, E.; Becker, D.; Rupprecht, H.; Neumayer, H.H.

    1997-01-01

    Aim: The clinical impact of perfusion scintigraphy versus color coded Duplex sonography was evaluated, with respect to their potential in assessing minimal allograft perfusion in vitally threatened kidney transplants, i.e. oligoanuric allografts suspected to have either severe rejection or thrombosis of the renal vein or artery. Methods: From July 1990 to August 1994 the grafts of 15 out of a total of 315 patients were vitally threatened. Technetium-99m DTPA scintigraphy and color coded Duplex sonography were performed in all patients. For scintigraphic evaluation of transplant perfusion analog scans up to 60 min postinjection, and time-activity curves over the first 60 sec after injection of 370-440 MBq Tc-99m diethylenetriaminepentaacetate acid (DTPA) were used and classified by a perfusion score, the time between renal and iliac artery peaks (TDiff) and the washout of the renogram curve. Additionally, evaluation of excretion function and assessment of vascular or urinary leaks were performed. By color coded Duplex sonography the perfusion in all sections of the graft as well as the vascular anastomoses were examined and the maximal blood flow velocity (Vmax) and the resistive index (RI) in the renal artery were determined by means of the pulsed Doppler device. Pathologic-anatomical diagnosis was achieved by either biopsy or post-explant histology in all grafts. Results: Scintigraphy and color coded Duplex sonography could reliably differentiate minimal (8/15) and not perfused (7/15) renal allografts. The results were confirmed either by angiography in digital subtraction technique (DSA) or the clinical follow up. Conclusion: In summary, perfusion scintigraphy and color coded Duplex sonography are comparable modalities to assess kidney graft perfusion. In clinical practice scintigraphy and colorcoded Doppler sonography can replace digital subtraction angiography in the evaluation of minimal allograft perfusion. (orig.) [de

  15. The role of sonography in patients with breast cancer presenting as an axillary mass

    International Nuclear Information System (INIS)

    Park, Sun Young; Kim, Eun Kyung; Oh, Ki Keun; Lee, Kyong Sik; Park, Byeong Woo

    2002-01-01

    To compare sonography and mammography in terms of their diagnostic value in breast cancer cases which initially presented as an axillary mass without a palpable mass or other clinical symptoms. Seven patients with enlarged axillary lymph nodes who first presented with no evidence of palpable breast lesions and who underwent both mammography and sonography were enrolled in this study. In six of the seven, the presence of metastatic adenocarcinoma was confirmed preoperatively by axillary needle aspiration biopsy; in four, subsequent sonographically guided breast core biopsy performed after careful examination of the primary site indicated that primary breast cancer was present. In each case, the radiologic findings were evaluated by both breast sonography and mammography. Breast lesions were detected mammographically in four of seven cases (57%); in three of the four, the lesion presented as a mass, and in one as microcalcification. In three of these four detected cases, fatty or scattered fibroglandular breast parenchyma was present; in one, the parenchyma was dense. In the three cases in which lesions were not detected, mammography revealed the presence of heterogeneously dense parenchyma. Breast sonography showed that lesions were present in six of seven cases (86%); in the remaining patient, malignant microcalcification was detected at mammography. Final pathologic examination indicated that all breast lesions except one, which was a ductal carcinoma in situ, with microinvasion, were infiltrating ductal carcinomas whose size ranged from microscopic to greater than 3 cm. At the time of this study, all seven patients were alive and well, having been disease free for up to 61 months after surgery. In women with a palpable axillary mass confirmed as metastatic adenocarcinoma, breast sonography may be a valuable adjunct to mammography

  16. Using modern teaching strategies to teach upper abdominal sonography to medical students.

    Science.gov (United States)

    Cheng, Wei-Chun; Lin, Xi-Zhang; Chen, Chiung-Yu

    2013-07-01

    Upper abdominal sonography can help physicians to confirm the diagnosis of various hepatobiliary diseases. Teaching sonography skills to medical students is important because it may enhance their level of knowledge and overall development during their gastroenterology section rotation. Sonographic imaging is abstract and students can be easily confused when scanning the abdominal structures from different sites and directions. We used several modern teaching strategies to facilitate the learning of sonography skills. The year five medical students beginning a gastroenterology section rotation for their first-year clerkship were taught abdominal sonography skills. Abstract sonographic images were related to concrete objects and the surrounding structures were further indicated. Each of the images was given a specific name and was sorted according to the scanning site. A mnemonics system was designed to help students to memorize the names of these images. A badge was created to recognize the achievement of being able to complete a basic upper abdominal sonography. Students were free (i.e., not obligated) to request a demonstration opportunity to show their skills within 2 weeks after receiving tutelage. We recorded the number of students who received training and were able to successfully complete the task; these individuals then received a badge to be pinned onto their white coats. Sixty-three of 68 students (92.6%) requested evaluation and all of them passed. We have greatly simplified the process of learning about upper abdominal sonography by using andragogy to enhance learning, mnemonics to help memory, and a pin-badge reward system to stimulate incentives. Copyright © 2013. Published by Elsevier B.V.

  17. Geoportale del Consorzio LaMMA Disseminazione di dati meteo in near real-time tramite standard OGC e software Open Source

    Directory of Open Access Journals (Sweden)

    Simone Giannechini

    2014-02-01

    The innovative aspect of this po rtal is the fact that it currently is ingesting, fusing and disseminating geospatial data related to the MetOcfield from various sources in near real-time in a comp rehensive manner that allows users to create add ed value visualizations for the support of operational use cases as well as to access and download underlying data (where app licable.

  18. Duplex sonography of the near-surface leg veins; Duplexsonographie der oberflaechlichen Beinvenen

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, E.

    2007-07-01

    The book contains the following contributions: The ultrasonograph, selection of the ultrasonic transducer, anatomy of the near-surface vein system, physiology of the near-surface vein system, varicose status classification, systematics of the duplex sonography of near-surface leg veins, provocational maneuver for the duplex sonographic varicose diagnostics, exploration of vena saphena parva, perforans veins, side branches, phlebitis, sonography for varicose therapy, postsurgical sonography, deep leg veins, examination of near-surface leg veins for the pathology of the deep vein system, differential diagnostic clarification of leg oedema from the phlebologic-lymphological view, diagnostic side features along the near-surface leg veins.

  19. FPGA-based real-time embedded system for RISS/GPS integrated navigation.

    Science.gov (United States)

    Abdelfatah, Walid Farid; Georgy, Jacques; Iqbal, Umar; Noureldin, Aboelmagd

    2012-01-01

    Navigation algorithms integrating measurements from multi-sensor systems overcome the problems that arise from using GPS navigation systems in standalone mode. Algorithms which integrate the data from 2D low-cost reduced inertial sensor system (RISS), consisting of a gyroscope and an odometer or wheel encoders, along with a GPS receiver via a Kalman filter has proved to be worthy in providing a consistent and more reliable navigation solution compared to standalone GPS receivers. It has been also shown to be beneficial, especially in GPS-denied environments such as urban canyons and tunnels. The main objective of this paper is to narrow the idea-to-implementation gap that follows the algorithm development by realizing a low-cost real-time embedded navigation system capable of computing the data-fused positioning solution. The role of the developed system is to synchronize the measurements from the three sensors, relative to the pulse per second signal generated from the GPS, after which the navigation algorithm is applied to the synchronized measurements to compute the navigation solution in real-time. Employing a customizable soft-core processor on an FPGA in the kernel of the navigation system, provided the flexibility for communicating with the various sensors and the computation capability required by the Kalman filter integration algorithm.

  20. The demonstration of gall stones by sonography and radiography

    International Nuclear Information System (INIS)

    Gladisch, R.; Deininger, H.K.; Staedtische Kliniken Darmstadt

    1983-01-01

    Eighty-seven unselected gall stones were examined radiologically and by ultrasound in vitro. No relationship of diagnostic value could be established between the amount of calcification and stone demonstration, the sonogram being influenced by the size of the stone, its surface contour and its position in the ultrasound beam. Sonography is therefore not suitable for selecting those patients on whom litholysis could be carried out. Sonography appears to be useful only in a negative way by establishing the exact size of the concretion. (orig.) [de

  1. Radiology of the male breast. Radiologische Diagnostik der maennlichen Brustdruese. Mammographie, Sonographie, pathohistologische Korrelation

    Energy Technology Data Exchange (ETDEWEB)

    Buchberger, W; Penz, T; Strasser, K [Innsbruck Univ. (Austria). Universitaetsklinik fuer Radiodiagnostik; Toetsch, M [Innsbruck Univ. (Austria). Inst. fuer Pathologische Anatomie

    1991-09-01

    61 men with breast enlargement underwent mammography; complementary sonography was performed in 34 cases. Diagnoses included gynaecomastia in 53 cases, pseudogynaecomastia in 9 cases, 3 carcinomas, 2 inflammatory lesions and 1 lipoma. Mammography and sonography can differentiate reliably true gynaecomastia from pseudogynaecomastia. Gynaecomastia and especially inflammatory lesions may not always be readily differentiated from carcinoma. Sonography can be helpful by demonstrating hyperreflexive glandular tissue, whereas carcinomas are usually hypoechoic. (orig./GDG).

  2. Central venous cannulation: are routine chest radiographs necessary after B-mode and colour Doppler sonography check?

    International Nuclear Information System (INIS)

    Lanza, Cecilia; Fabrizzi, Giancarlo; Russo, Marco

    2006-01-01

    After the insertion of a central venous catheter, a chest radiograph is usually obtained to ensure correct positioning of the catheter tip. To determine in a paediatric population whether B-mode and colour Doppler sonography after central venous access is useful to evaluate catheter position, thus obviating the need for a postprocedural radiograph. A prospective study of 107 consecutive central venous access procedures placed in a paediatric intensive care unit was performed. At the end of the procedure, B-mode and colour Doppler sonography were used to assess catheter position and check for complications. A postprocedural chest radiograph was obtained in all patients. In 96 patients postprocedural B-mode and colour Doppler sonography showed colour Doppler signals within the vena cava. Among the 11 patients predicted to have a potential complication, there was one pneumothorax and ten malpositions. Chest radiography showed a total of 13 complications - 1 pneumothorax and 12 malpositions. The concordance between colour Doppler sonography and chest radiography was 98.1% in the detection of catheter position; sonography had a sensitivity of 84.6% and a specificity of 100%. The close concordance between B-mode and colour Doppler sonography and chest radiography justifies the more frequent use of sonography to evaluate catheter position because ionizing radiation is eliminated. Chest radiography may then be performed only when there is suspected inappropriate catheter tip position after sonography. (orig.)

  3. Process algebra with timing : real time and discrete time

    NARCIS (Netherlands)

    Baeten, J.C.M.; Middelburg, C.A.; Bergstra, J.A.; Ponse, A.J.; Smolka, S.A.

    2001-01-01

    We present real time and discrete time versions of ACP with absolute timing and relative timing. The starting-point is a new real time version with absolute timing, called ACPsat, featuring urgent actions and a delay operator. The discrete time versions are conservative extensions of the discrete

  4. Process algebra with timing: Real time and discrete time

    NARCIS (Netherlands)

    Baeten, J.C.M.; Middelburg, C.A.

    1999-01-01

    We present real time and discrete time versions of ACP with absolute timing and relative timing. The startingpoint is a new real time version with absolute timing, called ACPsat , featuring urgent actions and a delay operator. The discrete time versions are conservative extensions of the discrete

  5. The accuracy of chest sonography in the diagnosis of small pleural effusion

    International Nuclear Information System (INIS)

    Kocijancic, I.

    2003-01-01

    Background. The aim of the study was to evaluate the accuracy of chest sonography in the radiological diagnosis of small pleural effusions. Patients and methods. Patients referred for abdominal and/or chest sonographies for various reasons were examined for sonographic features of pleural effusion. From January 1997 till January 2000, 69 patients were included into the study. Fifty-two patients were found to have pleural effusion not exceeding 15 mm in depth, the rest of them served as controls. Subsequently erect posteroanterior and expiratory lateral decubitus projections were done in all patients. Results. Compared to radiological examination chest sonography had a positive predictive value of 92% in the diagnosis of small pleural effusions in our study population. The mean thickness of fluid was 9.2 mm on ultrasonography and 7.6 mm on expiratory lateral decubitus views (P<0.01). Conclusions. Chest sonography showed a high degree of accuracy for demonstrating small pleural effusions and could replace lateral decubitus chest radiographs adequately. (author)

  6. Real-time radiography

    International Nuclear Information System (INIS)

    Bossi, R.H.; Oien, C.T.

    1981-01-01

    Real-time radiography is used for imaging both dynamic events and static objects. Fluorescent screens play an important role in converting radiation to light, which is then observed directly or intensified and detected. The radiographic parameters for real-time radiography are similar to conventional film radiography with special emphasis on statistics and magnification. Direct-viewing fluoroscopy uses the human eye as a detector of fluorescent screen light or the light from an intensifier. Remote-viewing systems replace the human observer with a television camera. The remote-viewing systems have many advantages over the direct-viewing conditions such as safety, image enhancement, and the capability to produce permanent records. This report reviews real-time imaging system parameters and components

  7. Diagnosis of hydronephrosis: comparison of radionuclide scanning and sonography

    International Nuclear Information System (INIS)

    Malave, S.R.; Neiman, H.L.; Spies, S.M.; Cisternino, S.J.; Adamo, G.

    1980-01-01

    Diagnostic sonographic and radioisotope scanning techniques have been shown to be useful in the diagnosis of obstructive uropathy. The accuracy of both methods was compared and sonography was found to provide the more accurate data (sensitivity, 90%, specificity, 98%; accuracy, 97%). Sonography provides excellent anatomic information and enables one to grade the degree of dilatation. Renal radionuclide studies were less sensitive in detecting obstruction, particularly in the presence of chronic renal disease, but offered additional information regarding relative renal blood flow, total effective renal plasma flow, and interval change in renal parenchymal function

  8. Ideal Positions: 3D Sonography, Medical Visuality, Popular Culture.

    Science.gov (United States)

    Seiber, Tim

    2016-03-01

    As digital technologies are integrated into medical environments, they continue to transform the experience of contemporary health care. Importantly, medicine is increasingly visual. In the history of sonography, visibility has played an important role in accessing fetal bodies for diagnostic and entertainment purposes. With the advent of three-dimensional (3D) rendering, sonography presents the fetus visually as already a child. The aesthetics of this process and the resulting imagery, made possible in digital networks, discloses important changes in the relationship between technology and biology, reproductive health and political debates, and biotechnology and culture.

  9. Real-time vision systems

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R.; Hernandez, J.E.; Lu, Shin-yee [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    Many industrial and defence applications require an ability to make instantaneous decisions based on sensor input of a time varying process. Such systems are referred to as `real-time systems` because they process and act on data as it occurs in time. When a vision sensor is used in a real-time system, the processing demands can be quite substantial, with typical data rates of 10-20 million samples per second. A real-time Machine Vision Laboratory (MVL) was established in FY94 to extend our years of experience in developing computer vision algorithms to include the development and implementation of real-time vision systems. The laboratory is equipped with a variety of hardware components, including Datacube image acquisition and processing boards, a Sun workstation, and several different types of CCD cameras, including monochrome and color area cameras and analog and digital line-scan cameras. The equipment is reconfigurable for prototyping different applications. This facility has been used to support several programs at LLNL, including O Division`s Peacemaker and Deadeye Projects as well as the CRADA with the U.S. Textile Industry, CAFE (Computer Aided Fabric Inspection). To date, we have successfully demonstrated several real-time applications: bullet tracking, stereo tracking and ranging, and web inspection. This work has been documented in the ongoing development of a real-time software library.

  10. An economic evaluation of first-trimester genetic sonography for prenatal detection of Down syndrome.

    Science.gov (United States)

    Vintzileos, A M; Ananth, C V; Fisher, A J; Smulian, J C; Day-Salvatore, D; Beazoglou, T

    1998-04-01

    To determine 1) the diagnostic accuracy requirements of first-trimester genetic sonography from the cost-benefit point of view and 2) the economic impact of first-trimester genetic sonography for the United States on the basis of the accuracy of previously published studies. A cost-benefit equation was developed on the basis of the hypothesis that the cost of chorionic villus sampling (CVS) in pregnant women with advanced maternal age (at least 35 years old) should be at least equal to the cost of genetic sonography with CVS used only for those with abnormal ultrasound results. The components of the equation included the diagnostic accuracy of genetic ultrasound (sensitivity and specificity for detecting Down syndrome), the costs of the CVS package and genetic ultrasound, and the lifetime cost of Down syndrome cases. First-trimester genetic sonography was found to be beneficial if the overall sensitivity for detecting Down syndrome was greater than 70%, and even then, the cost-benefit ratio depended on the corresponding false-positive rate. The required minimum ultrasound sensitivity varied according to the maternal age-specific prevalence of Down syndrome and ranged between 40% (for women 35 years old) to 96% (for women 44 years old). Of eight published cohorts using nuchal translucency thickness for genetic sonography, five had accuracies of genetic ultrasound compatible with net benefits. The benefits of first-trimester genetic sonography depend on its diagnostic accuracy. First-trimester genetic sonography has the potential for annual savings of 22 million dollars in the United States.

  11. Women's perception of transvaginal sonography in a tertiary hospital in nigeria

    International Nuclear Information System (INIS)

    Eze, C.U.; Okaro, A.O.; Nwobi, I.C.

    2008-01-01

    Available studies suggest that pregnant women's views on the desirability of routine ultrasound are Influenced by their perceptions of its potential benefits and concern about possible adverse effects. To assess women's views of transvaginal sonography and to determine any correlation between their perception of the procedure and their prior knowledge and experience of it. We surveyed women presenting with various gynecologic problems or complications of the first trimester. Data collection was by self-administered questionnaires using conveniences sampling technique on women attending the clinic over a period of one year. Only women who had transvaginal sonography were included. A total of 250 women were recruited and interviewed. Transvaginal sonography was considered not embarrassing by 76%, acceptable by 86%, not painful by 87.2% and not stressful by 82% of the women. There were no statistically significant differences in the women's perception of the procedure whether they had prior knowledge and previous experience of the procedure or not (P>0.05). The majority of the women perceived transvaginal sonography favourably. Their perception of the Procedure was favourable whether they had prior knowledge and previous experience of it or not. (author)

  12. Memory controllers for real-time embedded systems predictable and composable real-time systems

    CERN Document Server

    Akesson, Benny

    2012-01-01

      Verification of real-time requirements in systems-on-chip becomes more complex as more applications are integrated. Predictable and composable systems can manage the increasing complexity using formal verification and simulation.  This book explains the concepts of predictability and composability and shows how to apply them to the design and analysis of a memory controller, which is a key component in any real-time system. This book is generally intended for readers interested in Systems-on-Chips with real-time applications.   It is especially well-suited for readers looking to use SDRAM memories in systems with hard or firm real-time requirements. There is a strong focus on real-time concepts, such as predictability and composability, as well as a brief discussion about memory controller architectures for high-performance computing. Readers will learn step-by-step how to go from an unpredictable SDRAM memory, offering highly variable bandwidth and latency, to a predictable and composable shared memory...

  13. Magnetic resonance tomography and ultrasound in rheumatology; MRT und Sonographie in der Rheumatologie

    Energy Technology Data Exchange (ETDEWEB)

    Kainberger, F. [Universitaetsklinik fuer Radiodiagnostik, Ludwig-Boltzmann-Inst. fuer Physikalische und Radiologische Tumordiagnostik, Wien (Austria); Czerny, C. [Universitaetsklinik fuer Radiodiagnostik, Ludwig-Boltzmann-Inst. fuer Physikalische und Radiologische Tumordiagnostik, Wien (Austria); Trattnig, S. [Universitaetsklinik fuer Radiodiagnostik, Ludwig-Boltzmann-Inst. fuer Physikalische und Radiologische Tumordiagnostik, Wien (Austria); Lack, W. [Universitaetsklinik fuer Orthopaedie, Wien (Austria); Machold, K. [Universitaetsklinik fuer Innere Medizin III, Wien (Austria). Abt. fuer Rheumatologie; Graninger, W. [Universitaetsklinik fuer Innere Medizin III, Wien (Austria). Abt. fuer Rheumatologie

    1996-08-01

    Technical innovations and software improvements in magnetic resonance imaging (MRI) and high-resolution sonography (US) have definitely influenced the diagnostic imaging of rheumatic diseases. For MRI, improvements in surface coils, dedicated low-field systems (0.2 T), and software improvements (shorter acquisition times and refinements of fat suppressing techniques) must be mentioned. For sonography, the main innovations concern the development of higher transducer frequencies (7-15 Mhz) and power Doppler imaging. Clinical evaluations have shown that MRI and US are most useful in cases of suspected rheumatic disease with negative plain film radiographs and for documenting the course of the disease, diagnosing of early rheumatoid arthritis, making a differential diagnosis in clinically unclear rheumatic diseases, investigating vascularization, and quantifying pannus formation. In order to improve diagnostic efficacy the role of MRI and US in the management of patients with rheumatic disease should be reconsidered. (orig.) [Deutsch] Technische Innovationen in Hard- und Software von Magnetresonanztomographie (MRT) und Sonographiegeraeten haben die bildgebende Diagnostik in der Rheumatologie massgeblich beeinflusst (Verbesserungen der Oberflaechenspulen mit hohen Gradientenfeldern, dedizierte Niederfeldgeraete, Softwareverbesserungen in Form von kuerzeren Aquisitionszeiten und Verfeinerungen in der Fettunterdrueckung, hoehere Transducerfrequenzen zwischen 7 und 15 Mhz, Powerdopplerverfahren). Fuer die klinische Anwendung bedeutet dies, dass MRT und Sonographie als bildgebende Zusatzverfahren nach der Anfertigung konventioneller Roentgenaufnahmen anzuwenden sind, wenn diese unauffaellige Resultate ergeben oder spezielle Fragen zur Schwere des Krankheitsprozesses bzw. von Folgeerscheinungen zu beantworten sind. Im besonderen betrifft dies den Nachweis der Frueharthritis, die Differentialdiagnose klinisch nicht klar einzuordnender Krankheitsbilder und die Bestimmung des

  14. Noninvasive Prenatal Diagnosis of Hypohidrotic Ectodermal Dysplasia by Tooth Germ Sonography.

    Science.gov (United States)

    Wünsche, S; Jüngert, J; Faschingbauer, F; Mommsen, H; Goecke, T; Schwanitz, K; Stepan, H; Schneider, H

    2015-08-01

    Hypohidrotic ectodermal dysplasia, a potentially life-threatening heritable disorder, may be recognized already in utero by characteristic features such as oligodontia and mandibular hypoplasia. As therapeutic options and prognosis depend on the time point of diagnosis, early recognition was attempted during routine prenatal ultrasound examinations. Fetuses of nine pregnant women (one triplet and eight singleton pregnancies) with family histories of hypohidrotic ectodermal dysplasia were investigated by sonography between the 20th and 24th week of gestation. In 4 male and 2 female fetuses reduced amounts of tooth germs were detected, whereas 5 fetal subjects showed the normal amount. Three-dimensional ultrasound evaluation revealed mandibular hypoplasia in 5 of the 6 fetuses with oligodontia. Molecular genetic analysis and/or clinical findings after birth confirmed the prenatal sonographic diagnosis in each subject. In subjects with a family history of hypohidrotic ectodermal dysplasia, the diagnosis of this rare condition can be established noninvasively by sonography in the second trimester of pregnancy. Early recognition of the disorder may help to prevent dangerous hyperthermic episodes in infancy and may allow timely therapeutic interventions. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Is real-time elastography helpful to differentiate acute from subacute deep venous thrombosis? A preliminary study.

    Science.gov (United States)

    Aslan, Ahmet; Barutca, Hakan; Ayaz, Ercan; Aslan, Mine; Kocaaslan, Cemal; Inan, Ibrahim; Sahin, Sinan; Yıkılmaz, Ali

    2018-02-01

    To detect and characterize changes in stiffness of thrombus in patients with acute and subacute deep venous thrombosis (DVT) by using real-time elastography (RTE). Fifty-eight patients with acute or subacute DVT were prospectively evaluated by B-mode sonography (US), color Doppler US (CDUS), and RTE. Two radiologists evaluated the thrombus echogenicity, compressibility, and recanalization of the affected vein, and thrombus stiffness in consensus. The thrombi were classified into 3 groups as soft, intermediate, and hard on RTE images. The final study group consisted of 30 patients with acute DVT, among whom 10 were women (33%), and 19 patients with subacute DVT, among whom 6 were women (32%). The presence of hypoechoic thrombus, incompressible vein, and absence of recanalization on US and CDUS were significantly associated with acute DVT (P Venous thrombus hardens with age; however, elastography pattern on RTE, in its present form, may not be able to differentiate acute DVT from subacute DVT. © 2017 Wiley Periodicals, Inc.

  16. Sonography as a new diagnostic procedure for investigating abnormalities of the shoulder

    International Nuclear Information System (INIS)

    Rapf, C.; Furtschegger, A.; Resch, H.; Innsbruck Univ.

    1986-01-01

    Eighty-one sonographic examinations of patients with complaints relating to the shoulder joint have shown that this is the method next in value to radiological examination. So far, lesions of the rotator cuff and of the long head of the biceps could only be demonstrated by invasive procedures such as arthrography or arthroscopy. In these situations, sonography attains a similar accuracy. Diffuse lesions can also be diagnosed correctly, making arthrography and arthroscopy unnecessary. In addition, sonography can demonstrate inflammatory and degenerative changes and incomplete sub-acromial and intermediary tears of the rotator cuff, unlike conventional diagnostic methods. In future, arthrography and arthroscopy will only be necessary as additional diagnostic methods if sonography remains inconclusive. (orig.) [de

  17. Stress Urinary lncontinence : Comparative Study of Perineal Sonography in Erect Position and Chain Cystourethrograpy

    Energy Technology Data Exchange (ETDEWEB)

    Han, Gi Seok; Kim, Seung Hyup; Yeon, Kyung Mo; Han, Man Chung; Paick, Jae Seung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1995-06-15

    Authors investigated the diagnostic value of perineal sonography in erect position for patients with stress urinary incontinence. Perineal sonography and chain cystourethrography were performed in 18 female patients(mean age 51.2) with stress urinary incontinence. The posterior are throvesical angles in stress and rest states were measured in both studies and compared with each other. Mean posteriorurethrovesical angles({+-}2 standard error) in rest and stress states were 136.3({+-}7.2) .deg. , and 145.9({+-}7.0) .deg. for chain cystourethrography and 131.4({+-}5.6) .deg. and 143.4({+-}5.9) .deg. for perineal sonography, respectively. The data frorm both studies correlated well with cach other. Perineal sonography inerect position is easy,non-invasive technique and may substitute the chain cystourethrography in the evaluation of the patients with stress urinary in continece

  18. Essays in real-time forecasting

    OpenAIRE

    Liebermann, Joelle

    2012-01-01

    This thesis contains three essays in the field of real-time econometrics, and more particularlyforecasting.The issue of using data as available in real-time to forecasters, policymakers or financialmarkets is an important one which has only recently been taken on board in the empiricalliterature. Data available and used in real-time are preliminary and differ from ex-postrevised data, and given that data revisions may be quite substantial, the use of latestavailable instead of real-time can s...

  19. Retrobulbar Hematoma from Warfarin Toxicity and the Limitations of Bedside Ocular Sonography

    Science.gov (United States)

    2010-05-01

    worldwide. Peer Reviewed Title: Retrobulbar Hematoma from Warfarin Toxicity and the Limitations of Bedside Ocular Sonography Journal Issue: Western...Preferred Citation: Thompson D, Stanescu C, Pryor P, Laselle B. Retrobulbar Hematoma from Warfarin Toxicity and the Limitations of Bedside Ocular...nontrauamtic retrobulbar hematoma associated with warfarin toxicity. The application and limitations of focused bedside ocular sonography for this

  20. Transcranial Doppler sonography in familial hemiplegic migraine

    International Nuclear Information System (INIS)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A.

    1991-01-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab

  1. Transcranial Doppler sonography in familial hemiplegic migraine

    Energy Technology Data Exchange (ETDEWEB)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A. (Universita la Sapienza, Roma (Italy))

    1991-02-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab.

  2. Ovation Prime Real-Time

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Ovation Prime Real-Time (OPRT) product is a real-time forecast and nowcast model of auroral power and is an operational implementation of the work by Newell et...

  3. Power Doppler sonography and ultrasound contrast agent in assessing rheumatoid synovitis

    Directory of Open Access Journals (Sweden)

    F. Salaffi

    2011-09-01

    Full Text Available Pannus formation is a fundamental event in the pathogenesis of rheumatoid arthritis and its hypervascularisation seems to be crucial to the development of joint damage. High-resolution greyscale ultrasonography is a safe, quick, and inexpensive imaging tool that allows an accurate detection of even minimal morphostructural changes in patients with rheumatoid arthritis, including joint effusion, thickening of synovial membrane and bone erosions. More recently, power Doppler sonography has proved to be a reliable tool for semiquantitative assessment of the vascularity of the synovial tissue. The contrast-enhanced power Doppler sonography seems to be a helpful adjunct in assessing synovitis and the therapeutic response to the different therapies in patients with rheumatoid arthritis. The aim of this radiological vignette was to show a representative example of use of power Doppler sonography with contrast agent in assessing rheumatoid synovitis.

  4. Usefulness of high-resolution sonography in early diagnosis of rabbit clonorchiasis

    International Nuclear Information System (INIS)

    Lim, Jae Hoon; Choi, Don Gil; Chung, Il Gyu; Phyun, Lae Hyun; Pyeun, Yong Seon; Hong, Sung Tae; Lee, Me Jeong

    1999-01-01

    To determine the role of high-resolution sonography in the early diagnosis of experimentally induced clonorchiasis in rabbits. We performed sonographic examination weekly in 22 lightly-infected rabbits (10 rabbits infected with 10 metacercariae, 6 rabbits infected with 20 metacercariae, and 6 rabbits infected with 40 metacercariae), and 10 heavily-infected rabbits (500 metacercariae). The sonographic criterion of diagnosis with dilatation of the intrahepatic ducts. We sacrificed lightly-infected rabbits and counted numbers of adult worms of clonorchis sinensis 9 weeks after infection. Sonographic abnormalities were found 3 weeks after infection in 2 lightly-infected rabbits and 5 heavily-infected rabbits. On sonography at 9 weeks after infection, we observed dilatation of the intrahepatic ducts in 11 (65%) of 17 lightly-infected rabbits and all of 10 heavily-infected rabbits. High-resolution sonography is very useful in early diagnosis of rabbits clonorchiasis.

  5. Usefulness of high-resolution sonography in early diagnosis of rabbit clonorchiasis

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jae Hoon; Choi, Don Gil; Chung, Il Gyu; Phyun, Lae Hyun; Pyeun, Yong Seon [Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of); Hong, Sung Tae; Lee, Me Jeong [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1999-09-15

    To determine the role of high-resolution sonography in the early diagnosis of experimentally induced clonorchiasis in rabbits. We performed sonographic examination weekly in 22 lightly-infected rabbits (10 rabbits infected with 10 metacercariae, 6 rabbits infected with 20 metacercariae, and 6 rabbits infected with 40 metacercariae), and 10 heavily-infected rabbits (500 metacercariae). The sonographic criterion of diagnosis with dilatation of the intrahepatic ducts. We sacrificed lightly-infected rabbits and counted numbers of adult worms of clonorchis sinensis 9 weeks after infection. Sonographic abnormalities were found 3 weeks after infection in 2 lightly-infected rabbits and 5 heavily-infected rabbits. On sonography at 9 weeks after infection, we observed dilatation of the intrahepatic ducts in 11 (65%) of 17 lightly-infected rabbits and all of 10 heavily-infected rabbits. High-resolution sonography is very useful in early diagnosis of rabbits clonorchiasis.

  6. Evaluation of renal allograft rejection by Doppler sonography and MR imaging

    International Nuclear Information System (INIS)

    Steinberg, H.V.; Nelson, R.C.; Murphy, F.B.; Baumgartner, B.R.; Bourke, E.; Delaney, V.B.; Whelchel, J.B.; Bernardino, M.E.

    1986-01-01

    The authors prospectively studies the efficacy of Doppler sonography and MR imaging in evaluating renal allografts, with specific attention to transplant rejection. Based on study findings, we were unable to make a statement with respect to the appearance or accuracy of diagnosing cyclosporin toxicity or acute tubular necrosis by either modality due to concomitant rejection in the few patients so afflicted. Moreover, the ability to predict and diagnose the presence or absence of allograft rejection was not affected by different serum creatinine values. Most important, however, Doppler sonography was shown to be superior to MR imaging in evaluating for allograft rejection, as evidenced by its higher sensitivity (100% vs. 71%), specificity (88% vs. 75%), and accuracy (96% vs. 73%). Thus, because of its low cost and ease of accessibility, Doppler sonography should become the primary modality for renal transplant screening

  7. Outbursts In Symbiotic Binaries (FUSE 2000)

    Science.gov (United States)

    Kenyon, Scott J.; Sonneborn, George (Technical Monitor)

    2002-01-01

    During the past year, we made good progress on analysis of FUSE observations of the symbiotic binary Z And. For background, Z And is a binary system composed of a red giant and a hot component of unknown status. The orbital period is roughly 750 days. The hot component undergoes large-scale eruptions every 10-20 yr. An outburst began several years ago, triggering this FUSE opportunity. First, we obtained an excellent set of ground-based optical data in support, of the FUSE observations. We used FAST, a high throughput low resolution spectrograph on the 1.5-m telescope at Mt. Hopkins, Arizona. A 300 g/ mm grating blazed at 4750 A, a 3 in. slit, and a thinned Loral 512 x 2688 CCD gave us spectra covering 3800-7500 A at a resolution of 6 A. The wavelength solution for each spectrum has a probable error of +/- 0.5 A or better. Most of the resulting spectra have moderate signal-to-noise, S/.N approx. greater than 30 per pixel. The time coverage for these spectra is excellent. Typically, we acquired spectra every 1-2 nights during dark runs at Mt. Hopkins. These data cover most of the rise and all of the decline of the recent outburst. The spectra show a wealth of emission lines, including H I, He I, He II, [Fe V11], and the Raman scattering bands at 6830 A and 7088 A. The Raman bands and other high ionization features vary considerably throughout the outburst. These features will enable us to correlate variations in the FUSE spectra with variations in the optical spectra. Second, we began an analysis of FUSE spectra of Z And. We have carefully examined the spectra, identifying real features and defects. We have identified and measured fluxes for all strong emission lines, including the O VI doublet at 1032 A and 1038 A. These and several other strong emission lines display pronounced P Cygni absorption components indicative of outgrowing gas. We will attempt to correlate these velocities with similar profiles observed on optical spectra. The line velocities - together

  8. Stress Urinary lncontinence : Comparative Study of Perineal Sonography in Erect Position and Chain Cystourethrograpy

    International Nuclear Information System (INIS)

    Han, Gi Seok; Kim, Seung Hyup; Yeon, Kyung Mo; Han, Man Chung; Paick, Jae Seung

    1995-01-01

    Authors investigated the diagnostic value of perineal sonography in erect position for patients with stress urinary incontinence. Perineal sonography and chain cystourethrography were performed in 18 female patients(mean age 51.2) with stress urinary incontinence. The posterior are throvesical angles in stress and rest states were measured in both studies and compared with each other. Mean posteriorurethrovesical angles(±2 standard error) in rest and stress states were 136.3(±7.2) .deg. , and 145.9(±7.0) .deg. for chain cystourethrography and 131.4(±5.6) .deg. and 143.4(±5.9) .deg. for perineal sonography, respectively. The data frorm both studies correlated well with cach other. Perineal sonography inerect position is easy,non-invasive technique and may substitute the chain cystourethrography in the evaluation of the patients with stress urinary in continece

  9. Acute testicular torsion in children: the role of sonography in the diagnostic workup.

    Science.gov (United States)

    Gunther, P; Schenk, J P; Wunsch, R; Holland-Cunz, S; Kessler, U; Troger, J; Waag, K L

    2006-11-01

    Acute testicular torsion in children is an emergency and has to be diagnosed urgently. Doppler sonography is increasingly used in imaging the acute scrotum. Nevertheless, in uncertain cases, surgical exploration is required. In this study, we attempted to define the role of Doppler sonography in the diagnostic workup of the acutely painful scrotum. All patients admitted between 1999 and 2005 with acute scrotal pain were included. After clinical assessment, patients were imaged by Doppler sonography with a ''high-end'' instrument. In cases of absent arterial perfusion of the testis in Doppler sonography, surgical exploration was carried out. Patients with unaffected perfusion were followed clinically by ultrasound for up to 2 years. Sixty-one infants and children aged 1 day to 17 years (median: 7.9 years) were included. In 14 cases, sonography demonstrated absent central perfusion, with abnormal parenchymal echogenicity in six. Absence of venous blood flow together with reduction of central arterial perfusion was found in one infant. In these 15 patients, surgical exploration confirmed testicular torsion. Among the other 46 patients, we found four cases with increased testicular perfusion and 27 with increased perfusion of the epididymis. In one infant, a testicular tumour was found sonographically, and orchiectomy confirmed diagnosis of a teratoma. Follow-up examinations of the conservatively treated patients showed good clinical outcome with physiologic central perfusion as well as normal echogenic pattern of both testes. No case of testicular torsion was missed. By means of Doppler sonography, an unequivocal statement regarding testicular perfusion was possible in all cases. The initial Doppler diagnosis was confirmed by operative evaluation and follow-up ultrasound. Testicular torsion can therefore be excluded by correctly performed ultrasound with modern equipment.

  10. VERSE - Virtual Equivalent Real-time Simulation

    Science.gov (United States)

    Zheng, Yang; Martin, Bryan J.; Villaume, Nathaniel

    2005-01-01

    Distributed real-time simulations provide important timing validation and hardware in the- loop results for the spacecraft flight software development cycle. Occasionally, the need for higher fidelity modeling and more comprehensive debugging capabilities - combined with a limited amount of computational resources - calls for a non real-time simulation environment that mimics the real-time environment. By creating a non real-time environment that accommodates simulations and flight software designed for a multi-CPU real-time system, we can save development time, cut mission costs, and reduce the likelihood of errors. This paper presents such a solution: Virtual Equivalent Real-time Simulation Environment (VERSE). VERSE turns the real-time operating system RTAI (Real-time Application Interface) into an event driven simulator that runs in virtual real time. Designed to keep the original RTAI architecture as intact as possible, and therefore inheriting RTAI's many capabilities, VERSE was implemented with remarkably little change to the RTAI source code. This small footprint together with use of the same API allows users to easily run the same application in both real-time and virtual time environments. VERSE has been used to build a workstation testbed for NASA's Space Interferometry Mission (SIM PlanetQuest) instrument flight software. With its flexible simulation controls and inexpensive setup and replication costs, VERSE will become an invaluable tool in future mission development.

  11. Computational model of exploding metallic fuses for multimegajoule switching

    International Nuclear Information System (INIS)

    Lindemuth, I.R.; Brownell, J.H.; Greene, A.E.; Nickel, G.H.; Oliphant, T.A.; Weiss, D.L.

    1985-01-01

    A new model for determining the time-dependent behavior of exploding metallic fuses is formulated. The model draws on an atomic data base and gives insight into the temporal behavior of the material density and temperature of the fuse as well as the nonlinear electrical circuit interaction. The model includes an embedding insulating tamper and leads to a plausible explanation of fuse ''restrike.'' The model predicts time-scale compression of 500 for inductive store systems powered by explosive driven magnetic flux compression generators. A scenario for achieving multimegajoule foil implosions is predicted

  12. Pre-Operative Planning Using Real-Time Virtual Sonography, an MRI/Ultrasound Image Fusion Technique, for Breast-Conserving Surgery in Patients with Non-Mass Enhancement on Breast MRI: A Preliminary Study.

    Science.gov (United States)

    Ando, Takahito; Ito, Yukie; Ido, Mirai; Osawa, Manami; Kousaka, Junko; Mouri, Yukako; Fujii, Kimihito; Nakano, Shogo; Kimura, Junko; Ishiguchi, Tsuneo; Watanebe, Rie; Imai, Tsuneo; Fukutomi, Takashi

    2018-07-01

    The purpose of this retrospective study was to evaluate the effect of pre-operative planning using real-time virtual sonography (RVS), a magnetic resonance imaging (MRI)/ultrasound (US) image fusion technique on breast-conserving surgery (BCS) in patients with non-mass enhancement (NME) on breast MRI. Between 2011 and 2015, we enrolled 12 consecutive patients who had lesions with NME that exceeded the US hypo-echoic area, in which it was particularly difficult to evaluate the tumor margin. During pre-operative planning before breast-conserving surgery, RVS was used to delineate the enhancing area on the breast surface after additional supine breast MRI was performed. We analyzed both the surgical margin positivity rate and the re-operation rate. All NME lesions corresponded to the index cancer. In all patients, the diameter of the NME lesion was greater than that of the hypo-echoic lesion. The median diameters of the NME and hypo-echoic lesions were 24 mm (range: 12-39 mm) and 8.0 mm (range: 4.9-18 mm), respectively (p = 0.0002). After RVS-derived skin marking was performed on the surface of the affected breast, lumpectomy and quadrantectomy were conducted in 7 and 5 patients, respectively. The surgical margins were negative in 10 (83%) patients. Two patients with positive margins were found to have ductal carcinoma in situ in 1 duct each, 2.4 and 3.2 mm from the resection margin, respectively. None of the patients required additional resection. Although further prospective studies are required, the findings of our preliminary study suggest that it is very well possible that the use of RVS-derived skin marking during pre-operative planning for BCS in patients with NME would have resulted in surgical outcomes similar to or better than those obtained without the use of such marking. Copyright © 2018. Published by Elsevier Inc.

  13. ISTTOK real-time architecture

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Ivo S., E-mail: ivoc@ipfn.ist.utl.pt; Duarte, Paulo; Fernandes, Horácio; Valcárcel, Daniel F.; Carvalho, Pedro J.; Silva, Carlos; Duarte, André S.; Neto, André; Sousa, Jorge; Batista, António J.N.; Hekkert, Tiago; Carvalho, Bernardo B.

    2014-03-15

    Highlights: • All real-time diagnostics and actuators were integrated in the same control platform. • A 100 μs control cycle was achieved under the MARTe framework. • Time-windows based control with several event-driven control strategies implemented. • AC discharges with exception handling on iron core flux saturation. • An HTML discharge configuration was developed for configuring the MARTe system. - Abstract: The ISTTOK tokamak was upgraded with a plasma control system based on the Advanced Telecommunications Computing Architecture (ATCA) standard. This control system was designed to improve the discharge stability and to extend the operational space to the alternate plasma current (AC) discharges as part of the ISTTOK scientific program. In order to accomplish these objectives all ISTTOK diagnostics and actuators relevant for real-time operation were integrated in the control system. The control system was programmed in C++ over the Multi-threaded Application Real-Time executor (MARTe) which provides, among other features, a real-time scheduler, an interrupt handler, an intercommunications interface between code blocks and a clearly bounded interface with the external devices. As a complement to the MARTe framework, the BaseLib2 library provides the foundations for the data, code introspection and also a Hypertext Transfer Protocol (HTTP) server service. Taking advantage of the modular nature of MARTe, the algorithms of each diagnostic data processing, discharge timing, context switch, control and actuators output reference generation, run on well-defined blocks of code named Generic Application Module (GAM). This approach allows reusability of the code, simplified simulation, replacement or editing without changing the remaining GAMs. The ISTTOK control system GAMs run sequentially each 100 μs cycle on an Intel{sup ®} Q8200 4-core processor running at 2.33 GHz located in the ATCA crate. Two boards (inside the ATCA crate) with 32 analog

  14. ISTTOK real-time architecture

    International Nuclear Information System (INIS)

    Carvalho, Ivo S.; Duarte, Paulo; Fernandes, Horácio; Valcárcel, Daniel F.; Carvalho, Pedro J.; Silva, Carlos; Duarte, André S.; Neto, André; Sousa, Jorge; Batista, António J.N.; Hekkert, Tiago; Carvalho, Bernardo B.

    2014-01-01

    Highlights: • All real-time diagnostics and actuators were integrated in the same control platform. • A 100 μs control cycle was achieved under the MARTe framework. • Time-windows based control with several event-driven control strategies implemented. • AC discharges with exception handling on iron core flux saturation. • An HTML discharge configuration was developed for configuring the MARTe system. - Abstract: The ISTTOK tokamak was upgraded with a plasma control system based on the Advanced Telecommunications Computing Architecture (ATCA) standard. This control system was designed to improve the discharge stability and to extend the operational space to the alternate plasma current (AC) discharges as part of the ISTTOK scientific program. In order to accomplish these objectives all ISTTOK diagnostics and actuators relevant for real-time operation were integrated in the control system. The control system was programmed in C++ over the Multi-threaded Application Real-Time executor (MARTe) which provides, among other features, a real-time scheduler, an interrupt handler, an intercommunications interface between code blocks and a clearly bounded interface with the external devices. As a complement to the MARTe framework, the BaseLib2 library provides the foundations for the data, code introspection and also a Hypertext Transfer Protocol (HTTP) server service. Taking advantage of the modular nature of MARTe, the algorithms of each diagnostic data processing, discharge timing, context switch, control and actuators output reference generation, run on well-defined blocks of code named Generic Application Module (GAM). This approach allows reusability of the code, simplified simulation, replacement or editing without changing the remaining GAMs. The ISTTOK control system GAMs run sequentially each 100 μs cycle on an Intel ® Q8200 4-core processor running at 2.33 GHz located in the ATCA crate. Two boards (inside the ATCA crate) with 32 analog

  15. Intratumoral vascularity of experimentally induced VX2 carcinoma : comparison of power doppler sonography and microangiography

    International Nuclear Information System (INIS)

    Park, Kil Sun; Won, Hyung Jin; Seo, Joon Beom; Kim, Tae Kyoung; Han, Joon Koo; Choi, Byung Ihn

    1997-01-01

    To evaluate the usefulness and limitations of power Doppler sonography in determining the tumor vascularity Power Doppler sonography was performed on VX2 carcinomas present in rabbit thighs, and the findings were compared with those of microangiography in an almost identical plane. Tumor vascularity was qualitatively analysed on the basis of tumor vessel distribution and density, and the presence of thick and thin vesels;for a comparison of tumor vascularity as seen on microangiography, tumor blood flow signals shown by power Doppler sonography were graded 3, 2, 1, 0. For quantitative analysis, a comparison was made of the percentage of tumor area occupied by vessels, as shown in each study. Data analysis utilized the Wilcoxon signed-rank test and Spearman correlation test. Mean tumor vascularity scores, as seen on power Doppler sonography and relating to tumor vessel distribution and density, and the presence of thick and thin vessels, were 2.87, 2.73, 2.93 and 2.73, respectively. The means and medians of the percentages of tumor area occupied by vessels were 22.7% and 23.5% and 36.4% and 34.7% on microangiography and power Doppler sonography, respectively. Thus, there was good correlation between these two modes. Power doppler sonography could demonstrate the tumor vascularity on microangiography relatively well but tend to overestimate it

  16. Aerosol Emissions from Fuse-Deposition Modeling 3D Printers in a Chamber and in Real Indoor Environments.

    Science.gov (United States)

    Vance, Marina E; Pegues, Valerie; Van Montfrans, Schuyler; Leng, Weinan; Marr, Linsey C

    2017-09-05

    Three-dimensional (3D) printers are known to emit aerosols, but questions remain about their composition and the fundamental processes driving emissions. The objective of this work was to characterize the aerosol emissions from the operation of a fuse-deposition modeling 3D printer. We modeled the time- and size-resolved emissions of submicrometer aerosols from the printer in a chamber study, gained insight into the chemical composition of emitted aerosols using Raman spectroscopy, and measured the potential for exposure to the aerosols generated by 3D printers under real-use conditions in a variety of indoor environments. The average aerosol emission rates ranged from ∼10 8 to ∼10 11 particles min -1 , and the rates varied over the course of a print job. Acrylonitrile butadiene styrene (ABS) filaments generated the largest number of aerosols, and wood-infused polylactic acid (PLA) filaments generated the smallest amount. The emission factors ranged from 6 × 10 8 to 6 × 10 11 per gram of printed part, depending on the type of filament used. For ABS, the Raman spectra of the filament and the printed part were indistinguishable, while the aerosol spectra lacked important peaks corresponding to styrene and acrylonitrile, which are both present in ABS. This observation suggests that aerosols are not a result of volatilization and subsequent nucleation of ABS or direct release of ABS aerosols.

  17. Fuse Modeling for Reliability Study of Power Electronic Circuits

    DEFF Research Database (Denmark)

    Bahman, Amir Sajjad; Iannuzzo, Francesco; Blaabjerg, Frede

    2017-01-01

    This paper describes a comprehensive modeling approach on reliability of fuses used in power electronic circuits. When fuses are subjected to current pulses, cyclic temperature stress is introduced to the fuse element and will wear out the component. Furthermore, the fuse may be used in a large......, and rated voltage/current are opposed to shift in time to effect early breaking during the normal operation of the circuit. Therefore, in such cases, a reliable protection required for the other circuit components will not be achieved. The thermo-mechanical models, fatigue analysis and thermo...

  18. Three-dimensional power Doppler sonography: imaging and quantifying blood flow and vascularization.

    Science.gov (United States)

    Pairleitner, H; Steiner, H; Hasenoehrl, G; Staudach, A

    1999-08-01

    To assess the feasibility of imaging low-velocity blood flow in adnexal masses by transvaginal three-dimensional power Doppler sonography, to analyze three-dimensional power Doppler sonography data sets with a new computer-assisted method and to test the reproducibility of the technique. A commercially available 5-MHz Combison 530 ultrasound system was used to perform three-dimensional power Doppler sonography transvaginally. A cube (= volume of interest) was defined enclosing the vessels of the cyst and the Cartesian characteristics were stored on a hard disk. This cube was analyzed using specially designed software. Five indices representing vascularization (the vascularization index (VI) or blood flow (the flow index (FI)) or both (the vascularization-flow index (VFI)) were calculated. The intraobserver repeatability of cube definition and scan repetition was assessed using Hartley's test for homogeneous variances. Interobserver agreement was assessed by the Pearson correlation coefficient. Imaging of vessels with low-velocity blood flow by three-dimensional power Doppler sonography and cube definition was possible in all adnexal massed studied. In some cases even induced non-vascular flow related to endometriosis was detected. The calculated F value with intraobserver repeated Cartesian file-saving ranged from 0 to 18.8, with intraobserver scan repetition from 4.74 to 24.8 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the calculated F value was 64. The interobserver correlation coefficient ranged between 0.83 and 0.92 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the correlation coefficient was less than 0.75. Vessels with low-velocity blood flow can be imaged using three-dimensional power Doppler sonography. Induced non-vascular flow was detected in endometriotic cyst fluid. Three-dimensional power Doppler sonography combined with the cube method gave reproducible information for all indices except VFI 2. These indices might prove to be a new predictor in all fields of

  19. 99m-Tc DMSA scintigraphy and color/power doppler sonography for children pyelonephritis diagnosis and follow-up

    International Nuclear Information System (INIS)

    Hitzel, A.; Manrique, A.; Gardin, I.; Vera, P.; Hitzel, A.; Dacher, J.N.; Manrique, A.; Menard, J.F.; Gardin, I.; Vera, P.; Dacher, J.N.; Liard, A.; Menard, J.F.

    2004-01-01

    Early diagnosis of acute pyelonephritis is essential to avoid scarring development. This study was performed to evaluate capabilities of color/doppler sonography to detect pyelonephritis and to predict scarring when compared with 99m Tc-DMSA scintigraphy. Fifty-seven children were evaluated during pyelonephritis: biology (CRP, creatinine, blood formula), color/power doppler sonography and 99m Tc-DMSA scintigraphy (DMSA1). 7 ± 2 months later, follow-up consisted in biological tests and a 99m 'Tc-DMSA scintigraphy (DMSA2). During pyelonephritis, body temperature, CRP value and neutrophil counts were significantly higher in patients with an abnormal DMSA1 but not in patients with abnormal doppler sonography. When compared with DMSA1, doppler sonography sensitivity and specificity were 80% and 81% respectively. DMSA1 and doppler sonography were concordant in 86% of children with a pyelonephritis. At follow-up, all clinical et biological parameters were normalized. DMSA2 was abnormal in 51% of children. When compared with DMSA2, positive and negative predictive values for scarring of doppler sonography were 57% and 75% respectively. DMSA 1, positive and negative predictive values for scarring were 62% and 100%. In conclusion, color/power doppler sonography is a reliable tool for pyelonephritis diagnosis, but its predictive value for scarring is poor. Negative predictive value of DMSA scintigraphy is excellent. (author)

  20. A real-time architecture for time-aware agents.

    Science.gov (United States)

    Prouskas, Konstantinos-Vassileios; Pitt, Jeremy V

    2004-06-01

    This paper describes the specification and implementation of a new three-layer time-aware agent architecture. This architecture is designed for applications and environments where societies of humans and agents play equally active roles, but interact and operate in completely different time frames. The architecture consists of three layers: the April real-time run-time (ART) layer, the time aware layer (TAL), and the application agents layer (AAL). The ART layer forms the underlying real-time agent platform. An original online, real-time, dynamic priority-based scheduling algorithm is described for scheduling the computation time of agent processes, and it is shown that the algorithm's O(n) complexity and scalable performance are sufficient for application in real-time domains. The TAL layer forms an abstraction layer through which human and agent interactions are temporally unified, that is, handled in a common way irrespective of their temporal representation and scale. A novel O(n2) interaction scheduling algorithm is described for predicting and guaranteeing interactions' initiation and completion times. The time-aware predicting component of a workflow management system is also presented as an instance of the AAL layer. The described time-aware architecture addresses two key challenges in enabling agents to be effectively configured and applied in environments where humans and agents play equally active roles. It provides flexibility and adaptability in its real-time mechanisms while placing them under direct agent control, and it temporally unifies human and agent interactions.

  1. Diagnostic imaging strategy for MDCT- or MRI-detected breast lesions: use of targeted sonography

    International Nuclear Information System (INIS)

    Nakano, Satoko; Ohtsuka, Masahiko; Mibu, Akemi; Karikomi, Masato; Sakata, Hitomi; Yamamoto, Masahiro

    2012-01-01

    Leading-edge technology such as magnetic resonance imaging (MRI) or computed tomography (CT) often reveals mammographically and ultrasonographically occult lesions. MRI is a well-documented, effective tool to evaluate these lesions; however, the detection rate of targeted sonography varies for MRI detected lesions, and its significance is not well established in diagnostic strategy of MRI detected lesions. We assessed the utility of targeted sonography for multidetector-row CT (MDCT)- or MRI-detected lesions in practice. We retrospectively reviewed 695 patients with newly diagnosed breast cancer who were candidates for breast conserving surgery and underwent MDCT or MRI in our hospital between January 2004 and March 2011. Targeted sonography was performed in all MDCT- or MRI-detected lesions followed by imaging-guided biopsy. Patient background, histopathology features and the sizes of the lesions were compared among benign, malignant and follow-up groups. Of the 695 patients, 61 lesions in 56 patients were detected by MDCT or MRI. The MDCT- or MRI-detected lesions were identified by targeted sonography in 58 out of 61 lesions (95.1%). Patients with pathological diagnoses were significantly older and more likely to be postmenopausal than the follow-up patients. Pathological diagnosis proved to be benign in 20 cases and malignant in 25. The remaining 16 lesions have been followed up. Lesion size and shape were not significantly different among the benign, malignant and follow-up groups. Approximately 95% of MDCT- or MRI-detected lesions were identified by targeted sonography, and nearly half of these lesions were pathologically proven malignancies in this study. Targeted sonography is a useful modality for MDCT- or MRI-detected breast lesions

  2. Towards Real-Time Argumentation

    Directory of Open Access Journals (Sweden)

    Vicente JULIÁN

    2016-07-01

    Full Text Available In this paper, we deal with the problem of real-time coordination with the more general approach of reaching real-time agreements in MAS. Concretely, this work proposes a real-time argumentation framework in an attempt to provide agents with the ability of engaging in argumentative dialogues and come with a solution for their underlying agreement process within a bounded period of time. The framework has been implemented and evaluated in the domain of a customer support application. Concretely, we consider a society of agents that act on behalf of a group of technicians that must solve problems in a Technology Management Centre (TMC within a bounded time. This centre controls every process implicated in the provision of technological and customer support services to private or public organisations by means of a call centre. The contract signed between the TCM and the customer establishes penalties if the specified time is exceeded.

  3. The Benefit of Sonography in Pregnancy-associated Breast Cancer

    International Nuclear Information System (INIS)

    Son, Eun Ju; Oh, Ki Keun; Kim, Eun Kyung

    2005-01-01

    To evaluate the sonographic, mammographic and MRI features of pregnancy-associated breast cancer with the major focus on the sonographic benefit in a diagnosis of pregnancy associated breast cancer. From 1998 to 2002, sonography was performed on a total 7 patients (age 23 to 38 years), who were pathologically diagnosed with breast cancer during pregnancy. Six of those patients underwent mammography. Five patients underwent a breast MRI, preoperatively. The radiological findings were evaluated retrospectively. Six patients underwent surgery and 1 patient underwent a core biopsy and chemotherapy. The histological, nuclear grading and pathological staging were evaluated. The sonographic findings showed a mass with irregular shapes (n=6), irregular margins (n=6), a non-parallel orientation (n=5), complex echo patterns (n=5). Associated findings could be observed in 3 patients, including Cooper's ligament thickening (n=2), edema (n=2), skin thickening (n=1) and axillary lymphadenopathy (n=3). The sonographic findings were positive and showed masses in 6 patients. All the patients had a dense breast in mammography. The mammographic findings included masses (n=4), masses with microcalcifications (n=2), masses with axillary lymphadenopathy (n=3), calcifications alone (n=1), an asymmetric density alone (n=1), extremely dense breasts with negative findings (n=2). A breast MRI showed an irregular shaped mass (n=4) with a rim-like enhancement (n=3), linear ductal enhancement without a mass (n= 1), and the time intensity cure revealed the typical pattern and level of enhancement in the carcinoma. Sonography is a valuable tool for diagnosing pregnancy-associated breast cancer. However, mammography should be performed if there is a suspicious lesion on sonography in order to confirm the pregnancy-associated breast cancer. Mammography has a lower sensitivity during pregnancy due to the physiologic changes in the breasts. However, calcifications and associated findings are helpful

  4. Specific preoperative diagnosis of choledochal cysts by combined sonography and hepatobiliary scintigraphy

    International Nuclear Information System (INIS)

    Papanicolaou, N.; Abramson, S.J.; Teele, R.L.; Treves, S.

    1985-01-01

    The combined use of sonography and hepatobiliary scintigraphy correctly identified a choledochal cyst preoperatively in seven consecutive infants and children. The high resolution anatomic images provided by sonography coupled with physiologic data on filing of the cyst, biliary patency and liver function derived from radionuclide scanning offer valuable information in the diagnosis and planning of corrective surgery of the cyst and coexisting hepatobiliary anomalies. Invasive diagnostic procedures should be reserved for occasional problematic cases [fr

  5. [Performances and place of sonography in the diagnostic of endometriosis: CNGOF-HAS Endometriosis Guidelines].

    Science.gov (United States)

    Philip, C-A; Dubernard, G

    2018-03-01

    Endometriosis is difficult to diagnose clinically. Transvaginal sonography (TVS) is a procedure that is known to be operator-dependent, which mean that published evidences has to be balanced with the level of the sonographer that produced the data. The objective of this publication was to assess the performances of the sonography in the diagnosis of endometriosis in order to establish the French national recommendations. We searched the MEDLINE database for publication from January 2000 to September 2017 using keywords associated with endometriosis and sonography. Eighty-four trial and reviews published in English or French were included. Ovarian endometrioma can usually be diagnosed by a non-expert sonographer, especially when its aspect is typical. In case of an ovarian cyst with atypical presentation, it is recommended to control the sonography by a referent or to perform an MRI. In menopaused women, any ovarian cyst should be considered as a cancer until proven otherwise. In the diagnosis of posterior deep invasive endometriosis (DIE), TVS with sensitivity and specificity of 96 and 99% respectively, seems at least equivalent if not superior to MRI. However, these performances are related to expert sonographers. To reach sufficient efficiency in posterior DIE, the estimated learning curve for a sonographer is 44 cases. When posterior DIE is suspected, we recommend proposing a TVS "performed by an expert" or a MRI "at least interpreted by an expert". In anterior DIE, TVS has a good specificity (100%), but its sensitivity is poor in the literature (64%). TVS is therefore not able to eliminate the diagnosis. However a renal ultrasound should be proposed each time a urinary endometriosis is confirmed, and should be considered whenever posterior DIE is diagnosed especially the lesion is superior to 3cm. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  6. Real-time PCR in virology.

    Science.gov (United States)

    Mackay, Ian M; Arden, Katherine E; Nitsche, Andreas

    2002-03-15

    The use of the polymerase chain reaction (PCR) in molecular diagnostics has increased to the point where it is now accepted as the gold standard for detecting nucleic acids from a number of origins and it has become an essential tool in the research laboratory. Real-time PCR has engendered wider acceptance of the PCR due to its improved rapidity, sensitivity, reproducibility and the reduced risk of carry-over contamination. There are currently five main chemistries used for the detection of PCR product during real-time PCR. These are the DNA binding fluorophores, the 5' endonuclease, adjacent linear and hairpin oligoprobes and the self-fluorescing amplicons, which are described in detail. We also discuss factors that have restricted the development of multiplex real-time PCR as well as the role of real-time PCR in quantitating nucleic acids. Both amplification hardware and the fluorogenic detection chemistries have evolved rapidly as the understanding of real-time PCR has developed and this review aims to update the scientist on the current state of the art. We describe the background, advantages and limitations of real-time PCR and we review the literature as it applies to virus detection in the routine and research laboratory in order to focus on one of the many areas in which the application of real-time PCR has provided significant methodological benefits and improved patient outcomes. However, the technology discussed has been applied to other areas of microbiology as well as studies of gene expression and genetic disease.

  7. The role of colour Doppler sonography in the diagnosis of lower limb Klippel–Trénaunay syndrome

    International Nuclear Information System (INIS)

    Qi, H.T.; Wang, X.M.; Zhang, X.D.; Zhang, M.H.; Li, C.M.; Bao, S.G.; Yuan, H.

    2013-01-01

    Aim: To investigate the accuracy of colour Doppler sonography as compared to phlebography in patients with Klippel-Trénaunay syndrome (KTS). Materials and methods: From September 2004 to May 2012, 59 consecutive patients seen in Shandong medical imaging research institute with a clinical suggestion of KTS were included. Thirty-four were female and 25 were male, with a mean age of 28.4 years. Colour Doppler sonography was used to assess the lower limb veins. The main sonographic criteria for a positive diagnosis were visualization of the lateral vein or sciatic vein, capillary haemangioma, and abnormality of the deep veins. These data were compared with phlebography findings. The κ statistic was used to determine the level of agreement. The sensitivity, specificity, positive and negative predictive values, and accuracy of colour Doppler sonography as a diagnostic test were assessed. Results: Colour Doppler sonography findings were positive in 21 of 59 patients with a clinical suggestion of KTS. The diagnosis was confirmed using phlebography in 22 patients. There were two false-positive results and one false-negative result by colour Doppler sonography. The κ-value was 0.892. Sensitivity, specificity, positive and negative predictive values, and accuracy for colour Doppler sonography were 95.4, 94.6, 91.3, 97.2, and 94.9%, respectively. Conclusion: Colour Doppler sonography is an accurate, reliable, and non-invasive investigation in the assessment of patients with suspected KTS

  8. Real-Time Personalized Monitoring to Estimate Occupational Heat Stress in Ambient Assisted Working

    Directory of Open Access Journals (Sweden)

    Pablo Pancardo

    2015-07-01

    Full Text Available Ambient Assisted Working (AAW is a discipline aiming to provide comfort and safety in the workplace through customization and technology. Workers’ comfort may be compromised in many labor situations, including those depending on environmental conditions, like extremely hot weather conduces to heat stress. Occupational heat stress (OHS happens when a worker is in an uninterrupted physical activity and in a hot environment. OHS can produce strain on the body, which leads to discomfort and eventually to heat illness and even death. Related ISO standards contain methods to estimate OHS and to ensure the safety and health of workers, but they are subjective, impersonal, performed a posteriori and even invasive. This paper focuses on the design and development of real-time personalized monitoring for a more effective and objective estimation of OHS, taking into account the individual user profile, fusing data from environmental and unobtrusive body sensors. Formulas employed in this work were taken from different domains and joined in the method that we propose. It is based on calculations that enable continuous surveillance of physical activity performance in a comfortable and healthy manner. In this proposal, we found that OHS can be estimated by satisfying the following criteria: objective, personalized, in situ, in real time, just in time and in an unobtrusive way. This enables timely notice for workers to make decisions based on objective information to control OHS.

  9. Real time programming environment for Windows

    Energy Technology Data Exchange (ETDEWEB)

    LaBelle, D.R. [LaBelle (Dennis R.), Clifton Park, NY (United States)

    1998-04-01

    This document provides a description of the Real Time Programming Environment (RTProE). RTProE tools allow a programmer to create soft real time projects under general, multi-purpose operating systems. The basic features necessary for real time applications are provided by RTProE, leaving the programmer free to concentrate efforts on his specific project. The current version supports Microsoft Windows{trademark} 95 and NT. The tasks of real time synchronization and communication with other programs are handled by RTProE. RTProE includes a generic method for connecting a graphical user interface (GUI) to allow real time control and interaction with the programmer`s product. Topics covered in this paper include real time performance issues, portability, details of shared memory management, code scheduling, application control, Operating System specific concerns and the use of Computer Aided Software Engineering (CASE) tools. The development of RTProE is an important step in the expansion of the real time programming community. The financial costs associated with using the system are minimal. All source code for RTProE has been made publicly available. Any person with access to a personal computer, Windows 95 or NT, and C or FORTRAN compilers can quickly enter the world of real time modeling and simulation.

  10. An In-Home Digital Network Architecture for Real-Time and Non-Real-Time Communication

    NARCIS (Netherlands)

    Scholten, Johan; Jansen, P.G.; Hanssen, F.T.Y.; Hattink, Tjalling

    2002-01-01

    This paper describes an in-home digital network architecture that supports both real-time and non-real-time communication. The architecture deploys a distributed token mechanism to schedule communication streams and to offer guaranteed quality-ofservice. Essentially, the token mechanism prevents

  11. MARTe: A Multiplatform Real-Time Framework

    Science.gov (United States)

    Neto, André C.; Sartori, Filippo; Piccolo, Fabio; Vitelli, Riccardo; De Tommasi, Gianmaria; Zabeo, Luca; Barbalace, Antonio; Fernandes, Horacio; Valcarcel, Daniel F.; Batista, Antonio J. N.

    2010-04-01

    Development of real-time applications is usually associated with nonportable code targeted at specific real-time operating systems. The boundary between hardware drivers, system services, and user code is commonly not well defined, making the development in the target host significantly difficult. The Multithreaded Application Real-Time executor (MARTe) is a framework built over a multiplatform library that allows the execution of the same code in different operating systems. The framework provides the high-level interfaces with hardware, external configuration programs, and user interfaces, assuring at the same time hard real-time performances. End-users of the framework are required to define and implement algorithms inside a well-defined block of software, named Generic Application Module (GAM), that is executed by the real-time scheduler. Each GAM is reconfigurable with a set of predefined configuration meta-parameters and interchanges information using a set of data pipes that are provided as inputs and required as output. Using these connections, different GAMs can be chained either in series or parallel. GAMs can be developed and debugged in a non-real-time system and, only once the robustness of the code and correctness of the algorithm are verified, deployed to the real-time system. The software also supplies a large set of utilities that greatly ease the interaction and debugging of a running system. Among the most useful are a highly efficient real-time logger, HTTP introspection of real-time objects, and HTTP remote configuration. MARTe is currently being used to successfully drive the plasma vertical stabilization controller on the largest magnetic confinement fusion device in the world, with a control loop cycle of 50 ?s and a jitter under 1 ?s. In this particular project, MARTe is used with the Real-Time Application Interface (RTAI)/Linux operating system exploiting the new ?86 multicore processors technology.

  12. Real-Time and Real-Fast Performance of General-Purpose and Real-Time Operating Systems in Multithreaded Physical Simulation of Complex Mechanical Systems

    Directory of Open Access Journals (Sweden)

    Carlos Garre

    2014-01-01

    Full Text Available Physical simulation is a valuable tool in many fields of engineering for the tasks of design, prototyping, and testing. General-purpose operating systems (GPOS are designed for real-fast tasks, such as offline simulation of complex physical models that should finish as soon as possible. Interfacing hardware at a given rate (as in a hardware-in-the-loop test requires instead maximizing time determinism, for which real-time operating systems (RTOS are designed. In this paper, real-fast and real-time performance of RTOS and GPOS are compared when simulating models of high complexity with large time steps. This type of applications is usually present in the automotive industry and requires a good trade-off between real-fast and real-time performance. The performance of an RTOS and a GPOS is compared by running a tire model scalable on the number of degrees-of-freedom and parallel threads. The benchmark shows that the GPOS present better performance in real-fast runs but worse in real-time due to nonexplicit task switches and to the latency associated with interprocess communication (IPC and task switch.

  13. Impact of sonography in gouty arthritis: Comparison with conventional radiography, clinical examination, and laboratory findings

    International Nuclear Information System (INIS)

    Schueller-Weidekamm, Claudia; Schueller, Gerd; Aringer, Martin; Weber, Michael; Kainberger, Franz

    2007-01-01

    Objective: To explore the typical sonographic features of gray-scale and Power Doppler of acute and chronic gouty arthritis in conjunction with radiographic, clinical, and laboratory findings. Materials and methods: All hand, finger, and toe joints of 19 patients with acute and chronic gout were examined with gray-scale and Power Doppler sonography. The number and size of bone changes detected with sonography was compared to radiographic findings. Vascularization of the synovial tissue was scored on Power Doppler (grades 0-3), and was compared with clinical appearance, including swelling, tenderness, and redness (grades 0-3). Results: In acute gout, mild to moderate echogenic periarticular nodules with sonotransmission and hypervascularization of the edematous surrounding soft tissue were found. In chronic gout, tophaceous nodules completely blocked transmission of US wave, leading to strong reflexion and dorsal shadowing in a minority of cases. No significant difference in the detection of large bone changes (>2 mm) was found between sonography and radiography. However, gray-scale sonography was significantly more sensitive in the detection of small bone changes (p < 0.001). Power Doppler scores were statistically significantly higher than clinical examination scores (p < 0.001). Discussion: Sonography is superior to radiographs in evaluating small bone changes. The inflammatory process in joints can be better detected with Power Doppler sonography than with clinical examination. Typical sonographic appearance of acute and in particular of chronic gout might provide clues on gouty arthritis that adds to the information available from conventional radiography, clinical, and laboratory findings

  14. Impact of sonography in gouty arthritis: Comparison with conventional radiography, clinical examination, and laboratory findings

    Energy Technology Data Exchange (ETDEWEB)

    Schueller-Weidekamm, Claudia [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)]. E-mail: claudia.schueller-weidekamm@meduniwien.ac.at; Schueller, Gerd [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Aringer, Martin [Department of Rheumatology, Internal Medicine III, Medical University of Vienna (Austria); Weber, Michael [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Kainberger, Franz [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2007-06-15

    Objective: To explore the typical sonographic features of gray-scale and Power Doppler of acute and chronic gouty arthritis in conjunction with radiographic, clinical, and laboratory findings. Materials and methods: All hand, finger, and toe joints of 19 patients with acute and chronic gout were examined with gray-scale and Power Doppler sonography. The number and size of bone changes detected with sonography was compared to radiographic findings. Vascularization of the synovial tissue was scored on Power Doppler (grades 0-3), and was compared with clinical appearance, including swelling, tenderness, and redness (grades 0-3). Results: In acute gout, mild to moderate echogenic periarticular nodules with sonotransmission and hypervascularization of the edematous surrounding soft tissue were found. In chronic gout, tophaceous nodules completely blocked transmission of US wave, leading to strong reflexion and dorsal shadowing in a minority of cases. No significant difference in the detection of large bone changes (>2 mm) was found between sonography and radiography. However, gray-scale sonography was significantly more sensitive in the detection of small bone changes (p < 0.001). Power Doppler scores were statistically significantly higher than clinical examination scores (p < 0.001). Discussion: Sonography is superior to radiographs in evaluating small bone changes. The inflammatory process in joints can be better detected with Power Doppler sonography than with clinical examination. Typical sonographic appearance of acute and in particular of chronic gout might provide clues on gouty arthritis that adds to the information available from conventional radiography, clinical, and laboratory findings.

  15. Scalable Real-Time Negotiation Toolkit

    National Research Council Canada - National Science Library

    Lesser, Victor

    2004-01-01

    ... to implement an adaptive distributed sensor network. These activities involved the development of a distributed soft, real-time heuristic resource allocation protocol, the development of a domain-independent soft, real time agent architecture...

  16. Chest sonography. 2. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Mathis, Gebhard (ed.)

    2008-07-01

    Chest sonography is an established procedure in the stepwise imaging diagnosis of pulmonary and pleural disease. It is the method of choice to distinguish between solid and liquid lesions and allows the investigator to make an unequivocal diagnosis without exposing the patient to costly and stressful procedures. This book presents the state of the art in chest investigation by means of ultrasonography. A number of excellent illustrations and the compact text provide concise and easy-to-assimilate information about the diagnostic procedure. Basic elements such as indications, investigation techniques and image artifacts are detailed in separate chapters. (orig.)

  17. Chest sonography. 2. ed.

    International Nuclear Information System (INIS)

    Mathis, Gebhard

    2008-01-01

    Chest sonography is an established procedure in the stepwise imaging diagnosis of pulmonary and pleural disease. It is the method of choice to distinguish between solid and liquid lesions and allows the investigator to make an unequivocal diagnosis without exposing the patient to costly and stressful procedures. This book presents the state of the art in chest investigation by means of ultrasonography. A number of excellent illustrations and the compact text provide concise and easy-to-assimilate information about the diagnostic procedure. Basic elements such as indications, investigation techniques and image artifacts are detailed in separate chapters. (orig.)

  18. Muscle lesion comparing of imaging procedures (sonography and MRT) -experimental and clinical study

    International Nuclear Information System (INIS)

    Mellerowicz, H.; Lubasch, A.; Dulce, M.; Wagner, S.; Paul, B.

    1993-01-01

    Muscle injuries in sports are more common now. Diagnosis and follow up of muscle injuries is nowadays achieved by sonography and MRT. In order to assess the two imagine procedures, a direct test for comparison of sonography and MRT was performed in an experimental study: A standardised disconnection of m. triceps surae in rats was either sutured and glued or not treated. Clinical studies were performed in 26 patients suffering from muscle trauma. Sonography was proved to be a reliable procedure especially in follow up control until full weight bearing and should be used first. Negative or doubtfull findings require further investigation by MRT. Especially contrast medium (Gd-DTPA) assisted examinations enables a long term follow up and may even show small (muscle strain) and deep lying injuries. (orig.) [de

  19. Model Checking Real-Time Systems

    DEFF Research Database (Denmark)

    Bouyer, Patricia; Fahrenberg, Uli; Larsen, Kim Guldstrand

    2018-01-01

    This chapter surveys timed automata as a formalism for model checking real-time systems. We begin with introducing the model, as an extension of finite-state automata with real-valued variables for measuring time. We then present the main model-checking results in this framework, and give a hint...

  20. Modular specification of real-time systems

    DEFF Research Database (Denmark)

    Inal, Recep

    1994-01-01

    Duration Calculus, a real-time interval logic, has been embedded in the Z specification language to provide a notation for real-time systems that combines the modularisation and abstraction facilities of Z with a logic suitable for reasoning about real-time properties. In this article the notation...

  1. Hard Real-Time Networking on Firewire

    NARCIS (Netherlands)

    Zhang, Yuchen; Orlic, Bojan; Visser, Peter; Broenink, Jan

    2005-01-01

    This paper investigates the possibility of using standard, low-cost, widely used FireWire as a new generation fieldbus medium for real-time distributed control applications. A real-time software subsys- tem, RT-FireWire was designed that can, in combination with Linux-based real-time operating

  2. Multiprocessor scheduling for real-time systems

    CERN Document Server

    Baruah, Sanjoy; Buttazzo, Giorgio

    2015-01-01

    This book provides a comprehensive overview of both theoretical and pragmatic aspects of resource-allocation and scheduling in multiprocessor and multicore hard-real-time systems.  The authors derive new, abstract models of real-time tasks that capture accurately the salient features of real application systems that are to be implemented on multiprocessor platforms, and identify rules for mapping application systems onto the most appropriate models.  New run-time multiprocessor scheduling algorithms are presented, which are demonstrably better than those currently used, both in terms of run-time efficiency and tractability of off-line analysis.  Readers will benefit from a new design and analysis framework for multiprocessor real-time systems, which will translate into a significantly enhanced ability to provide formally verified, safety-critical real-time systems at a significantly lower cost.

  3. Correlation between sonography and antibody activity in patients with Hashimoto thyroiditis.

    Science.gov (United States)

    Willms, Arnulf; Bieler, Dan; Wieler, Helmut; Willms, Diana; Kaiser, Klaus P; Schwab, Robert

    2013-11-01

    Patients with Hashimoto thyroiditis show structural changes of the thyroid that can be identified by a variety of sonographic criteria. We conducted this study to investigate whether there is a correlation between sonography and antibody activity and to assess the role of sonography in the diagnosis and follow-up of Hashimoto thyroiditis. In addition, we present a new classification system (termed the VESINC system [volume, echogenicity, sonographic texture, pseudonodular hypoechoic infiltration, nodules, and cysts]), which helps improve the clarity of sonographic findings. The study included 223 consecutive patients with previously diagnosed Hashimoto autoimmune thyroiditis who attended the thyroid clinic of the German Armed Forces Central Hospital in Koblenz for follow-up examinations between 2006 and 2008. Laboratory tests were performed to measure the levels of free triiodothyronine, free thyroxine, thyrotropin, anti-thyroglobulin antibodies (TgAbs), and antithyroid peroxidase antibodies (TPOAbs). Sonography was performed according to a strict protocol. We then assessed whether a correlation existed between antibody activity and the 6 sonographic variables of the VESINC system. Hypoechogenicity, heterogeneity, and pseudonodular hypoechoic infiltration were associated with significantly higher TPOAb activity (P Hashimoto thyroiditis.

  4. Interobserver variability of sonography for prediction of placenta accreta.

    Science.gov (United States)

    Bowman, Zachary S; Eller, Alexandra G; Kennedy, Anne M; Richards, Douglas S; Winter, Thomas C; Woodward, Paula J; Silver, Robert M

    2014-12-01

    The sensitivity of sonography to predict accreta has been reported as higher than 90%. However, most studies are from single expert investigators. Our objective was to analyze interobserver variability of sonography for prediction of placenta accreta. Patients with previa with and without accreta were ascertained, and images with placental views were collected, deidentified, and placed in random sequence. Three radiologists and 3 maternal-fetal medicine specialists interpreted each study for the presence of accreta and specific findings reported to be associated with its diagnosis. Investigator-specific sensitivity, specificity, and accuracy were calculated. κ statistics were used to assess variability between individuals and types of investigators. A total of 229 sonographic studies from 55 patients with accreta and 56 control patients were examined. Accuracy ranged from 55.9% to 76.4%. Of imaging studies yielding diagnoses, sensitivity ranged from 53.4% to 74.4%, and specificity ranged from 70.8% to 94.8%. Overall interobserver agreement was moderate (mean κ ± SD = 0.47 ± 0.12). κ values between pairs of investigators ranged from 0.32 (fair agreement) to 0.73 (substantial agreement). Average individual agreement ranged from fair (κ = 0.35) to moderate (κ = 0.53). Blinded from clinical data, sonography has significant interobserver variability for the diagnosis of placenta accreta. © 2013 by the American Institute of Ultrasound in Medicine.

  5. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    International Nuclear Information System (INIS)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong; Kim, Jeong Ho; Park, Chul Hi

    2008-01-01

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean±standard deviation) of the beam hardening artifact was 4.5±0.8 cm in the arthroplastic knees and 3.9±2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients

  6. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong [Inha University, College of Medicine, Incheon (Korea, Republic of); Kim, Jeong Ho; Park, Chul Hi [Gachon University, Gil Medical Center, Incheon (Korea, Republic of)

    2008-02-15

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean{+-}standard deviation) of the beam hardening artifact was 4.5{+-}0.8 cm in the arthroplastic knees and 3.9{+-}2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients.

  7. Prototyping real-time systems

    OpenAIRE

    Clynch, Gary

    1994-01-01

    The traditional software development paradigm, the waterfall life cycle model, is defective when used for developing real-time systems. This thesis puts forward an executable prototyping approach for the development of real-time systems. A prototyping system is proposed which uses ESML (Extended Systems Modelling Language) as a prototype specification language. The prototyping system advocates the translation of non-executable ESML specifications into executable LOOPN (Language of Object ...

  8. MRI, CT, and sonography in the preoperative evaluation of primary tumor extension in malignant pleural mesothelioma; MRT, CT und Sonographie in der praeoperativen Beurteilung der Primaertumorausdehnung beim malignen Pleuramesotheliom

    Energy Technology Data Exchange (ETDEWEB)

    Layer, G.; Steudel, A.; Schild, H.H. [Radiologische Universitaetsklinik Bonn (Germany); Schmitteckert, H.; Tuengerthal, S.; Schirren, J. [Thoraxklinik Heidelberg-Rohrbach (Germany); Kaick, G. van [Deutsches Krebsforschungszentrum Heidelberg (Germany). Schwerpunkt fuer Onkologische Diagnostik und Therapie

    1999-04-01

    Purpose: Evaluation of the diagnostic value of the imaging modalities computed tomography (CT), magnetic resonance imaging (MRI), and thoracic sonography in the preoperative staging of malignant pleural mesothelioma. Results: The accuracy rates for CT were 85%, 98%, 83%, 73%, 71%, and 83%. MRI had an accuracy of 71%, 92%, 71%, 83%, 71%, and 96%, the thoracic ultrasound examinations of 76%, 63%, 51%, 60%, 71% and 89%. Conclusions: According to these results CT remains the method of choice in the preoperative assessment of T-stage of malignant pleural mesothelioma. MRI is of nearly the same value, but is not a must. Sonography may be supplementary method for operation planning. (orig./AJ) [Deutsch] Ziel: Evaluation der diagnostischen Wertigkeit der Schnittbildverfahren MRT, CT und Sonographie in der praeoperativen Diagnostik des Pleuramesothelioms. Ergebisse: Die Treffsicherheiten betrugen fuer die genannten anatomischen Regionen im CT 85%, 98%, 83%, 73%, 71%, und 83%, im MRT 71%, 92%, 71%, 83%, 71% bzw. 96%, waehrend sich fuer die thorakale Ultraschalluntersuchung Treffsicherheiten von 76%, 63%, 51%, 60%, 71% und 89% errechneten. Schlussfolgerungen: Die CT bleibt damit das Verfahren erster Wahl in der praeoperativen Diagnostik des malignen Pleuramesothelioms. Eine unbedingte Forderung nach praeoperativer Durchfuehrung einer MRT-Untersuchung ergibt sich nach der vorliegenden Studie nicht. Die Sonographie des Thorax und oberen Abdomens liefert einen wichtigen ergaenzenden Beitrag bei der Planung der Operation des malignen Pleuramesothelioms. (orig./AJ)

  9. IPS – A SYSTEM FOR REAL-TIME NAVIGATION AND 3D MODELING

    Directory of Open Access Journals (Sweden)

    D. Grießbach

    2012-07-01

    Full Text Available fdaReliable navigation and 3D modeling is a necessary requirement for any autonomous system in real world scenarios. German Aerospace Center (DLR developed a system providing precise information about local position and orientation of a mobile platform as well as three-dimensional information about its environment in real-time. This system, called Integral Positioning System (IPS can be applied for indoor environments and outdoor environments. To achieve high precision, reliability, integrity and availability a multi-sensor approach was chosen. The important role of sensor data synchronization, system calibration and spatial referencing is emphasized because the data from several sensors has to be fused using a Kalman filter. A hardware operating system (HW-OS is presented, that facilitates the low-level integration of different interfaces. The benefit of this approach is an increased precision of synchronization at the expense of additional engineering costs. It will be shown that the additional effort is leveraged by the new design concept since the HW-OS methodology allows a proven, flexible and fast design process, a high re-usability of common components and consequently a higher reliability within the low-level sensor fusion. Another main focus of the paper is on IPS software. The DLR developed, implemented and tested a flexible and extensible software concept for data grabbing, efficient data handling, data preprocessing (e.g. image rectification being essential for thematic data processing. Standard outputs of IPS are a trajectory of the moving platform and a high density 3D point cloud of the current environment. This information is provided in real-time. Based on these results, information processing on more abstract levels can be executed.

  10. Color doppler sonography in thickened gallbladder wall

    International Nuclear Information System (INIS)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki

    1996-01-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes

  11. Software Design Methods for Real-Time Systems

    Science.gov (United States)

    1989-12-01

    This module describes the concepts and methods used in the software design of real time systems . It outlines the characteristics of real time systems , describes...the role of software design in real time system development, surveys and compares some software design methods for real - time systems , and

  12. Real-time Pricing in Power Markets

    DEFF Research Database (Denmark)

    Boom, Anette; Schwenen, Sebastian

    We examine welfare e ects of real-time pricing in electricity markets. Before stochastic energy demand is known, competitive retailers contract with nal consumers who exogenously do not have real-time meters. After demand is realized, two electricity generators compete in a uniform price auction...... to satisfy demand from retailers acting on behalf of subscribed customers and from consumers with real-time meters. Increasing the number of consumers on real-time pricing does not always increase welfare since risk-averse consumers dislike uncertain and high prices arising through market power...

  13. Real-time Pricing in Power Markets

    DEFF Research Database (Denmark)

    Boom, Anette; Schwenen, Sebastian

    We examine welfare eects of real-time pricing in electricity markets. Before stochastic energy demand is known, competitive retailers contract with nal consumers who exogenously do not have real-time meters. After demand is realized, two electricity generators compete in a uniform price auction...... to satisfy demand from retailers acting on behalf of subscribed customers and from consumers with real-time meters. Increasing the number of consumers on real-time pricing does not always increase welfare since risk-averse consumers dislike uncertain and high prices arising through market power...

  14. Distributed, Embedded and Real-time Java Systems

    CERN Document Server

    Wellings, Andy

    2012-01-01

    Research on real-time Java technology has been prolific over the past decade, leading to a large number of corresponding hardware and software solutions, and frameworks for distributed and embedded real-time Java systems.  This book is aimed primarily at researchers in real-time embedded systems, particularly those who wish to understand the current state of the art in using Java in this domain.  Much of the work in real-time distributed, embedded and real-time Java has focused on the Real-time Specification for Java (RTSJ) as the underlying base technology, and consequently many of the Chapters in this book address issues with, or solve problems using, this framework. Describes innovative techniques in: scheduling, memory management, quality of service and communication systems supporting real-time Java applications; Includes coverage of multiprocessor embedded systems and parallel programming; Discusses state-of-the-art resource management for embedded systems, including Java’s real-time garbage collect...

  15. Research of real-time communication software

    Science.gov (United States)

    Li, Maotang; Guo, Jingbo; Liu, Yuzhong; Li, Jiahong

    2003-11-01

    Real-time communication has been playing an increasingly important role in our work, life and ocean monitor. With the rapid progress of computer and communication technique as well as the miniaturization of communication system, it is needed to develop the adaptable and reliable real-time communication software in the ocean monitor system. This paper involves the real-time communication software research based on the point-to-point satellite intercommunication system. The object-oriented design method is adopted, which can transmit and receive video data and audio data as well as engineering data by satellite channel. In the real-time communication software, some software modules are developed, which can realize the point-to-point satellite intercommunication in the ocean monitor system. There are three advantages for the real-time communication software. One is that the real-time communication software increases the reliability of the point-to-point satellite intercommunication system working. Second is that some optional parameters are intercalated, which greatly increases the flexibility of the system working. Third is that some hardware is substituted by the real-time communication software, which not only decrease the expense of the system and promotes the miniaturization of communication system, but also aggrandizes the agility of the system.

  16. Suspected leaking abdominal aortic aneurysm: use of sonography in the emergency room.

    Science.gov (United States)

    Shuman, W P; Hastrup, W; Kohler, T R; Nyberg, D A; Wang, K Y; Vincent, L M; Mack, L A

    1988-07-01

    To determine the value of sonography in the emergent evaluation of suspected leaking abdominal aortic aneurysms, the authors examined 60 patients in the emergency department using sonography and a protocol involving advance radio notification from the ambulance; arrival of sonographic personnel and equipment in the triage room before patient arrival; and, during other triage activities, rapid sonographic evaluation of the aorta for aneurysm and of the paraaortic region for extraluminal blood. Sonographic findings were correlated with surgical results and clinical outcome. When performed under these circumstances, sonography was accurate in demonstrating presence or absence of aneurysm (98%), but its sensitivity for extraluminal blood was poor (4%). A combination of sonographic confirmation of aneurysm, abdominal pain, and unstable hemodynamic condition resulted in the correct decision to perform emergent surgery in 21 of 22 patients (95%). An abbreviated sonographic examination done in the emergency room can provide accurate, useful information about the presence of aneurysm; this procedure does not significantly delay triage of these patients.

  17. Addison's disease with adrenal enlargement on sonography and computed toimography

    International Nuclear Information System (INIS)

    Renner, F.; Graninger, W.

    1986-01-01

    One of the major causes of chronic adrenal insufficiency (Addison's disease) is tuberculous adrenalopathy. Since sonography and computed tomography have become generally available in recent years and are of potential help in the diagnosis of this disease the merits of these methods are discussed in the light of 2 cases of adrenal tuberculosis, followed by a review of the literature. Adrenal calcification is the most significant, although not specific sign of adrenal insufficiency due to tuberculosis. Computed tomography has proven to be the method of choice in the non-invasive diagnosis of tuberculous adrenalopathy and in the monitoring of tuberculostatic treatment in this disease. Sonography is helpful as a preliminary investigation. (Author)

  18. Integration of MDSplus in real-time systems

    International Nuclear Information System (INIS)

    Luchetta, A.; Manduchi, G.; Taliercio, C.

    2006-01-01

    RFX-mod makes extensive usage of real-time systems for feedback control and uses MDSplus to interface them to the main Data Acquisition system. For this purpose, the core of MDSplus has been ported to VxWorks, the operating system used for real-time control in RFX. Using this approach, it is possible to integrate real-time systems, but MDSplus is used only for non-real-time tasks, i.e. those tasks which are executed before and after the pulse and whose performance does not affect the system time constraints. More extensive use of MDSplus in real-time systems is foreseen, and a real-time layer for MDSplus is under development, which will provide access to memory-mapped pulse files, shared by the tasks running on the same CPU. Real-time communication will also be integrated in the MDSplus core to provide support for distributed memory-mapped pulse files

  19. Dense time discretization technique for verification of real time systems

    International Nuclear Information System (INIS)

    Makackas, Dalius; Miseviciene, Regina

    2016-01-01

    Verifying the real-time system there are two different models to control the time: discrete and dense time based models. This paper argues a novel verification technique, which calculates discrete time intervals from dense time in order to create all the system states that can be reached from the initial system state. The technique is designed for real-time systems specified by a piece-linear aggregate approach. Key words: real-time system, dense time, verification, model checking, piece-linear aggregate

  20. Unenhanced helical CT in the evaluation of the urinary tract in children and young adults following urinary tract reconstruction: comparison with sonography

    Energy Technology Data Exchange (ETDEWEB)

    Myers, M.T.; Elder, J.S.; Sivit, C.J.; Applegate, K.E. [Dept. of Radiology, Rainbow Babies and Children' s Hospital, Cleveland, OH (United States)

    2001-03-01

    Purpose. To compare the accuracy of unenhanced, helical CT with sonography for the detection of complications of urinary tract reconstruction. Materials and methods. Forty-six kidneys in 24 patients were examined with CT and sonography. All scans were assessed for ease of renal visualization, presence of renal, ureteral, and bladder calculi, renal scars, hydronephrosis, and abdominal wall hernia. The results of both imaging modalities were independently reported. Results. CT provided excellent visualization of all 46 kidneys, while sonography provided poor visualization of 8 kidneys (17 %) (P < 0.001). CT detected calculi in 10 kidneys, 1 ureter, and 7 bladders. Sonography detected calculi in only 2 kidneys, and 2 bladders. Overall, CT detected significantly more calculi than US (18 vs 4, P = 0.01). CT detected scarring in 15 kidneys, while sonography detected scarring in 10. Hydronephrosis was detected in 6 kidneys by CT and in 8 kidneys by sonography. Three abdominal wall hernias were seen at CT that were not seen at sonography. Conclusion. CT is superior to sonography for the detection of urinary tract calculi and renal scarring. CT will demonstrate abdominal wall hernias that are unsuspected. (orig.)

  1. Preoperative magnetic resonance and intraoperative ultrasound fusion imaging for real-time neuronavigation in brain tumor surgery.

    Science.gov (United States)

    Prada, F; Del Bene, M; Mattei, L; Lodigiani, L; DeBeni, S; Kolev, V; Vetrano, I; Solbiati, L; Sakas, G; DiMeco, F

    2015-04-01

    Brain shift and tissue deformation during surgery for intracranial lesions are the main actual limitations of neuro-navigation (NN), which currently relies mainly on preoperative imaging. Ultrasound (US), being a real-time imaging modality, is becoming progressively more widespread during neurosurgical procedures, but most neurosurgeons, trained on axial computed tomography (CT) and magnetic resonance imaging (MRI) slices, lack specific US training and have difficulties recognizing anatomic structures with the same confidence as in preoperative imaging. Therefore real-time intraoperative fusion imaging (FI) between preoperative imaging and intraoperative ultrasound (ioUS) for virtual navigation (VN) is highly desirable. We describe our procedure for real-time navigation during surgery for different cerebral lesions. We performed fusion imaging with virtual navigation for patients undergoing surgery for brain lesion removal using an ultrasound-based real-time neuro-navigation system that fuses intraoperative cerebral ultrasound with preoperative MRI and simultaneously displays an MRI slice coplanar to an ioUS image. 58 patients underwent surgery at our institution for intracranial lesion removal with image guidance using a US system equipped with fusion imaging for neuro-navigation. In all cases the initial (external) registration error obtained by the corresponding anatomical landmark procedure was below 2 mm and the craniotomy was correctly placed. The transdural window gave satisfactory US image quality and the lesion was always detectable and measurable on both axes. Brain shift/deformation correction has been successfully employed in 42 cases to restore the co-registration during surgery. The accuracy of ioUS/MRI fusion/overlapping was confirmed intraoperatively under direct visualization of anatomic landmarks and the error was surgery and is less expensive and time-consuming than other intraoperative imaging techniques, offering high precision and

  2. Use of chest sonography in acute-care radiology☆

    Science.gov (United States)

    De Luca, C.; Valentino, M.; Rimondi, M.R.; Branchini, M.; Baleni, M. Casadio; Barozzi, L.

    2008-01-01

    Diagnosis of acute lung disease is a daily challenge for radiologists working in acute-care areas. It is generally based on the results of chest radiography performed under technically unfavorable conditions. Computed tomography (CT) is undoubtedly more accurate in these cases, but it cannot always be performed on critically ill patients who need continuous care. The use of thoracic ultrasonography (US) has recently been proposed for the study of acute lung disease. It can be carried out rapidly at the bedside and does not require any particularly sophisticated equipment. This report analyzes our experience with chest sonography as a supplement to chest radiography in an Emergency Radiology Unit. We performed chest sonography – as an adjunct to chest radiography – on 168 patients with acute chest pathology. Static and dynamic US signs were analyzed in light of radiographic findings and, when possible, CT. The use of chest US improved the authors' ability to provide confident diagnoses of acute disease of the chest and lungs. PMID:23397048

  3. Diabetic mastopathy: a diagnostic challenge in breast sonography.

    Science.gov (United States)

    Moschetta, Marco; Telegrafo, Michele; Triggiani, Vincenzo; Rella, Leonarda; Cornacchia, Ilaria; Serio, Gabriella; Ianora, Amato Antonio Stabile; Angelelli, Giuseppe

    2015-02-01

    Our purpose was to retrospectively evaluate the incidence and morphologic features of diabetic mastopathy in a group of patients with diabetes, searching for specific sonographic characteristics of diabetic mastopathy. One hundred twenty diabetic patients underwent breast clinical examination, mammography, and sonography. All detected breast lesions were confirmed histopathologically. Breast lesions were found in 11 of the 120 patients (9%), including two cases of invasive ductal carcinomas and nine cases of diabetic mastopathy. In seven of those nine cases (77%), diabetic mastopathy appeared as a hypoechoic solid mass with irregular margins, inhomogeneous echotexture, and marked posterior shadowing. In the other two cases (23%), it appeared as a mildly inhomogeneous, hypoechoic solid mass. Diabetic mastopathy is a diagnostic challenge and needs to be suspected in all patients with diabetes mellitus. Imaging features are nonspecific and highly susggestive on breast sonography in most cases. Core-needle biopsy confirmation remains mandatory for a definitive diagnosis. © 2015 Wiley Periodicals, Inc.

  4. Storm real-time processing cookbook

    CERN Document Server

    Anderson, Quinton

    2013-01-01

    A Cookbook with plenty of practical recipes for different uses of Storm.If you are a Java developer with basic knowledge of real-time processing and would like to learn Storm to process unbounded streams of data in real time, then this book is for you.

  5. Mixed - mode Operating System for Real - time Performance

    Directory of Open Access Journals (Sweden)

    Hasan M. M.

    2017-11-01

    Full Text Available The purpose of the mixed-mode system research is to handle devices with the accuracy of real-time systems and at the same time, having all the benefits and facilities of a matured Graphic User Interface(GUIoperating system which is typicallynon-real-time. This mixed-mode operating system comprising of a real-time portion and a non-real-time portion was studied and implemented to identify the feasibilities and performances in practical applications (in the context of scheduled the real-time events. In this research an i8751 microcontroller-based hardware was used to measure the performance of the system in real-time-only as well as non-real-time-only configurations. The real-time portion is an 486DX-40 IBM PC system running under DOS-based real-time kernel and the non-real-time portion is a Pentium IIIbased system running under Windows NT. It was found that mixed-mode systems performed as good as a typical real-time system and in fact, gave many additional benefits such as simplified/modular programming and load tolerance.

  6. Contrast-enhanced sonography for quantitative assessment of portal hypertension in patients with liver cirrhosis.

    Science.gov (United States)

    Qu, En-Ze; Zhang, Ying-Cai; Li, Zhi-Yan; Liu, Yang; Wang, Jin-Rui

    2014-11-01

    The clinical utility of contrast-enhanced sonography in portal hypertension remains unclear. We explored the feasibility of using contrast-enhanced sonography for noninvasive assessment of portal venous pressure. Twenty healthy individuals (control group; 9 men; mean age, 46.4 years) and 18 patients with portal hypertension (15 men; mean age, 46.2 years) were enrolled in this study. The portal hypertension group included patients who underwent splenectomy and pericardial blood vessel disarticulation at our hospital from October 2010 to March 2011. One week before surgery, patients with portal hypertension underwent preoperative liver contrast-enhanced sonography. Two-dimensional, Doppler, and contrast-enhanced sonographic parameters were compared between the groups. Portal venous pressure was measured intraoperatively by portal vein puncture in the portal hypertension group, and its relationship with the other parameters was analyzed. The 2-dimensional, Doppler, and contrast-enhanced sonographic parameters differed between the groups (P Portal venous pressure was inversely correlated with the area under the portal vein/hepatic artery time-intensity curve ratio (Qp/Qa), portal vein/hepatic artery strength ratio (Ip/Ia), and portal vein/hepatic artery wash-in perfusion slope ratio (βp/βa), with correlation coefficients of -0.701, -0.625, and -0.494, respectively. Measurement of the liver contrast-enhanced sonographic parameters Qp/Qa, Ip/Ia, and βp/βa could be used as a new quantitative method for noninvasively assessing portal venous pressure. © 2014 by the American Institute of Ultrasound in Medicine.

  7. Research in Distributed Real-Time Systems

    Science.gov (United States)

    Mukkamala, R.

    1997-01-01

    This document summarizes the progress we have made on our study of issues concerning the schedulability of real-time systems. Our study has produced several results in the scalability issues of distributed real-time systems. In particular, we have used our techniques to resolve schedulability issues in distributed systems with end-to-end requirements. During the next year (1997-98), we propose to extend the current work to address the modeling and workload characterization issues in distributed real-time systems. In particular, we propose to investigate the effect of different workload models and component models on the design and the subsequent performance of distributed real-time systems.

  8. Duplex sonography in portal hypertension

    International Nuclear Information System (INIS)

    Kwon, Hyuk Po; Jang, J. C.; Park, B. H.

    1990-01-01

    We measure the diameter and blood velocity of the portal vein in 50 patients with cirrhosis of the liver and 40 healthy subjects, and calculated cross sectional area, mean blood flow velocity, blood flow volume and congestion index. In patients with cirrhosis of the liver, the cross sectional area of the portal vein was significantly increased: the mean blood flow volume was significantly reduced; the blood flow volume was significantly increased; the congestion index of the portal vein was significantly increased. Duples sonography may play an important role in the diagnosis of portal hypertension

  9. Quantitative real-time monitoring of multi-elements in airborne particulates by direct introduction into an inductively coupled plasma mass spectrometer

    International Nuclear Information System (INIS)

    Suzuki, Yoshinari; Sato, Hikaru; Hiyoshi, Katsuhiro; Furuta, Naoki

    2012-01-01

    A new calibration system for real-time determination of trace elements in airborne particulates was developed. Airborne particulates were directly introduced into an inductively coupled plasma mass spectrometer, and the concentrations of 15 trace elements were determined by means of an external calibration method. External standard solutions were nebulized by an ultrasonic nebulizer (USN) coupled with a desolvation system, and the resulting aerosol was introduced into the plasma. The efficiency of sample introduction via the USN was calculated by two methods: (1) the introduction of a Cr standard solution via the USN was compared with introduction of a Cr(CO) 6 standard gas via a standard gas generator and (2) the aerosol generated by the USN was trapped on filters and then analyzed. The Cr introduction efficiencies obtained by the two methods were the same, and the introduction efficiencies of the other elements were equal to the introduction efficiency of Cr. Our results indicated that our calibration method for introduction efficiency worked well for the 15 elements (Ti, V, Cr, Mn, Co, Ni, Cu, Zn, As, Mo, Sn, Sb, Ba, Tl and Pb). The real-time data and the filter-collection data agreed well for elements with low-melting oxides (V, Co, As, Mo, Sb, Tl, and Pb). In contrast, the real-time data were smaller than the filter-collection data for elements with high-melting oxides (Ti, Cr, Mn, Ni, Cu, Zn, Sn, and Ba). This result implies that the oxides of these 8 elements were not completely fused, vaporized, atomized, and ionized in the initial radiation zone of the inductively coupled plasma. However, quantitative real-time monitoring can be realized after correction for the element recoveries which can be calculated from the ratio of real-time data/filter-collection data. - Highlights: ► APs were directly introduced into ICP-MS and real-time analysis was performed. ► The real-time data were calibrated by a multi-element standard solution from USN. ► During real-time

  10. Real-time data access layer for MDSplus

    International Nuclear Information System (INIS)

    Manduchi, G.; Luchetta, A.; Taliercio, C.; Fredian, T.; Stillerman, J.

    2008-01-01

    Recent extensions to MDSplus allow data handling in long discharges and provide a real-time data access and communication layer. The real-time data access layer is an additional component of MDSplus: it is possible to use the traditional MDSplus API during normal operation, and to select a subset of data items to be used in real time. Real-time notification is provided by a communication layer using a publish-subscribe pattern. The notification covers processes sharing the same data items even running on different machines, thus allowing the implementation of distributed control systems. The real-time data access layer has been developed for Windows, Linux, and VxWorks; it is currently being ported to Linux RTAI. In order to quantify the fingerprint of the presented system, the performance of the real-time access layer approach is compared with that of an ad hoc, manually optimized program in a sample real-time application

  11. A Real-Time Systems Symposium Preprint.

    Science.gov (United States)

    1983-09-01

    Real - Time Systems Symposium Preprint Interim Tech...estimate of the occurence of the error. Unclassii ledSECUqITY CLASSIF’ICA T" NO MI*IA If’ inDI /’rrd erter for~~ble. ’Corrputnqg A REAL - TIME SYSTEMS SYMPOSIUM...ABSTRACT This technical report contains a preprint of a paper accepted for presentation at the REAL - TIME SYSTEMS SYMPOSIUM, Arlington,

  12. Benefits of real-time gas management

    International Nuclear Information System (INIS)

    Nolty, R.; Dolezalek, D. Jr.

    1994-01-01

    In today's competitive gas gathering, processing, storage and transportation business environment, the requirements to do business are continually changing. These changes arise from government regulations such as the amendments to the Clean Air Act concerning the environment and FERC Order 636 concerning business practices. Other changes are due to advances in technology such as electronic flow measurement (EFM) and real-time communications capabilities within the gas industry. Gas gathering, processing, storage and transportation companies must be flexible in adapting to these changes to remain competitive. These dynamic requirements can be met with an open, real-time gas management computer information system. Such a system provides flexible services with a variety of software applications. Allocations, nominations management and gas dispatching are examples of applications that are provided on a real-time basis. By providing real-time services, the gas management system enables operations personnel to make timely adjustments within the current accounting period. Benefits realized from implementing a real-time gas management system include reduced unaccountable gas, reduced imbalance penalties, reduced regulatory violations, improved facility operations and better service to customers. These benefits give a company the competitive edge. This article discusses the applications provided, the benefits from implementing a real-time gas management system, and the definition of such a system

  13. The Significance of Brain Transcranial Sonography in Burning Mouth Syndrome: a Pilot Study.

    Science.gov (United States)

    Zavoreo, Iris; Vučićević, Vanja; Boras; Zadravec, Dijana; Bašić, Vanja; Kes; Ciliga, Dubravka; Gabrić, Dragana

    2017-03-01

    Burning mouth syndrome (BMS) is a chronic disorder which is affecting mostly postmenopausal women and is characterized by burning symptoms in the oral cavity on the clinically healthy oral mucosa. Also, the results of previous studies suggested a possible role of peripheral and/or central neurological disturbances in these patients. The aim of this study was to analyze patients with burning mouth syndrome using transcranial sonography. By use of transcranial sonography of the brain parenchyma, substantia nigra , midbrain raphe and brain nucleus were evaluated in 20 patients with BMS (64.7±12.3 years) and 20 controls with chronic pain in the lumbosacral region (61.5±15). Statistical analysis was performed by use of Student t test with significance set at pburning mouth syndrome might reflect central disturbances within this syndrome. Burning Mouth Syndrome; Transcranial Sonography; substantia nigra; Midbrain Raphe Nuclei; Red Nucleus.

  14. Making real-time reactive systems reliable

    Science.gov (United States)

    Marzullo, Keith; Wood, Mark

    1990-01-01

    A reactive system is characterized by a control program that interacts with an environment (or controlled program). The control program monitors the environment and reacts to significant events by sending commands to the environment. This structure is quite general. Not only are most embedded real time systems reactive systems, but so are monitoring and debugging systems and distributed application management systems. Since reactive systems are usually long running and may control physical equipment, fault tolerance is vital. The research tries to understand the principal issues of fault tolerance in real time reactive systems and to build tools that allow a programmer to design reliable, real time reactive systems. In order to make real time reactive systems reliable, several issues must be addressed: (1) How can a control program be built to tolerate failures of sensors and actuators. To achieve this, a methodology was developed for transforming a control program that references physical value into one that tolerates sensors that can fail and can return inaccurate values; (2) How can the real time reactive system be built to tolerate failures of the control program. Towards this goal, whether the techniques presented can be extended to real time reactive systems is investigated; and (3) How can the environment be specified in a way that is useful for writing a control program. Towards this goal, whether a system with real time constraints can be expressed as an equivalent system without such constraints is also investigated.

  15. Influence of System Parameters on Fuse Protection Use in Regenerative DC Drives

    Directory of Open Access Journals (Sweden)

    Isa Salman Qamber

    2009-06-01

    Full Text Available Current limiting fuses are widely used to protect the thyristors in DC drive systems. One very important problem is the choice of the correct voltage rating for fuses protecting regenerative DC drives, where many types of fault may occur, which makes fuse protection difficult. In the event of a commutation failure while regenerating, the fuses need to interrupt the loop supplied by the AC and DC voltages acting in series, which is the most difficult case for protection by fuses. In this paper a detailed study of the complete interruption process has been investigated by modeling of arcing process of the fuse protection against the regenerative circuit internal commutation fault. The effect of varying the motor time constant, supply impedance, number of fuses used to clear the fault and DC machine rating on the total transient response is studied. The model of a 200 A fuse is employed in this study. Fuses in series with both the semiconductor devices (F1 and fuses in AC lines (F2 are considered. Comparison was made between arc energy produced for fuses protecting the regenerative circuit if failure occurs, with the arc energy produced in a standard AC test in order to investigate the required voltage rating for the fuse.

  16. Space Weather and Real-Time Monitoring

    Directory of Open Access Journals (Sweden)

    S Watari

    2009-04-01

    Full Text Available Recent advance of information and communications technology enables to collect a large amount of ground-based and space-based observation data in real-time. The real-time data realize nowcast of space weather. This paper reports a history of space weather by the International Space Environment Service (ISES in association with the International Geophysical Year (IGY and importance of real-time monitoring in space weather.

  17. Research Directions in Real-Time Systems.

    Science.gov (United States)

    1996-09-01

    This report summarizes a survey of published research in real time systems . Material is presented that provides an overview of the topic, focusing on...communications protocols and scheduling techniques. It is noted that real - time systems deserve special attention separate from other areas because of...formal tools for design and analysis of real - time systems . The early work on applications as well as notable theoretical advances are summarized

  18. Real-Time MENTAT programming language and architecture

    Science.gov (United States)

    Grimshaw, Andrew S.; Silberman, Ami; Liu, Jane W. S.

    1989-01-01

    Real-time MENTAT, a programming environment designed to simplify the task of programming real-time applications in distributed and parallel environments, is described. It is based on the same data-driven computation model and object-oriented programming paradigm as MENTAT. It provides an easy-to-use mechanism to exploit parallelism, language constructs for the expression and enforcement of timing constraints, and run-time support for scheduling and exciting real-time programs. The real-time MENTAT programming language is an extended C++. The extensions are added to facilitate automatic detection of data flow and generation of data flow graphs, to express the timing constraints of individual granules of computation, and to provide scheduling directives for the runtime system. A high-level view of the real-time MENTAT system architecture and programming language constructs is provided.

  19. Real Time Conference 2016 Overview

    Science.gov (United States)

    Luchetta, Adriano

    2017-06-01

    This is a special issue of the IEEE Transactions on Nuclear Science containing papers from the invited, oral, and poster presentation of the 20th Real Time Conference (RT2016). The conference was held June 6-10, 2016, at Centro Congressi Padova “A. Luciani,” Padova, Italy, and was organized by Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA) and the Istituto Nazionale di Fisica Nucleare. The Real Time Conference is multidisciplinary and focuses on the latest developments in real-time techniques in high-energy physics, nuclear physics, astrophysics and astroparticle physics, nuclear fusion, medical physics, space instrumentation, nuclear power instrumentation, general radiation instrumentation, and real-time security and safety. Taking place every second year, it is sponsored by the Computer Application in Nuclear and Plasma Sciences technical committee of the IEEE Nuclear and Plasma Sciences Society. RT2016 attracted more than 240 registrants, with a large proportion of young researchers and engineers. It had an attendance of 67 students from many countries.

  20. Run-time middleware to support real-time system scenarios

    NARCIS (Netherlands)

    Goossens, K.; Koedam, M.; Sinha, S.; Nelson, A.; Geilen, M.

    2015-01-01

    Systems on Chip (SOC) are powerful multiprocessor systems capable of running multiple independent applications, often with both real-time and non-real-time requirements. Scenarios exist at two levels: first, combinations of independent applications, and second, different states of a single

  1. Advanced real-time manipulation of video streams

    CERN Document Server

    Herling, Jan

    2014-01-01

    Diminished Reality is a new fascinating technology that removes real-world content from live video streams. This sensational live video manipulation actually removes real objects and generates a coherent video stream in real-time. Viewers cannot detect modified content. Existing approaches are restricted to moving objects and static or almost static cameras and do not allow real-time manipulation of video content. Jan Herling presents a new and innovative approach for real-time object removal with arbitrary camera movements.

  2. Usefulness of sonography in women less than 35 years old with palpable breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Ju; Chung, Hyun Ung; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Gwangju (Korea, Republic of)

    1994-12-15

    To assess the usefulness of sonography in the evaluation of palpable mass in patients less than 35 years old,the breast sonograms and mammograms of 105 histopathologically proved cases were retrospectively reviewed. Breast parenchymal patterns on mammogram, sensitivity of sonography and mammography in the diagnosis of palpable breast masses, and sonographic findings of breast masses were analyzed. Grade IV breast parenchymal pattern was demonstrated in 44 of 76 mammogram (57.9%). The incidence of Grade IV pattern increased, as the patients' age became younger. The sensitivity of sonography (81.3%) was higher than that of mammography (45.3%) in the evaluation of the benign breast lesions. However, the sensitivity of both modalities were nearly equal (66.7% and 58.3% respectively) in the evaluation of the breast cancers. Sonographic findings of fibroadenoma included oval,well defined border, smooth contour, weak homogeneous internal echoes, posterior sonic enhancement, and bilateral shadows. On the other hand, breast cancer exhibited poorly defined border, irregular contour, and inhomogeneous hypoechoic mass with posterior sonic attenuation. In summary, sonography was useful in the evaluation of the palpable breast mass in women less than 35 years old. Choreoathetotic sonographic findings might help the differential diagnosis of breast masses

  3. Usefulness of sonography in women less than 35 years old with palpable breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Ju; Chung, Hyun Ung; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Gwangju (Korea, Republic of)

    1994-12-15

    To assess the usefulness of sonography in the evaluation of palpable mass in patients less than 35 years old,the breast sonograms and mammograms of 105 histopathologically proved cases were retrospectively reviewed. Breast parenchymal patterns on mammogram, sensitivity of sonography and mammography in the diagnosis of palpable breast masses, and sonographic findings of breast masses were analyzed. Grade IV breast parenchymal pattern was demonstrated in 44 of 76 mammogram (57.9%). The incidence of Grade IV pattern increased, as the patients' age became younger. The sensitivity of sonography (81.3%) was higher than that of mammography (45.3%) in the evaluation of the benign breast lesions. However, the sensitivity of both modalities were nearly equal (66.7% and 58.3% respectively) in the evaluation of the breast cancers. Sonographic findings of fibroadenoma included oval,well defined border, smooth contour, weak homogeneous internal echoes, posterior sonic enhancement, and bilateral shadows. On the other hand, breast cancer exhibited poorly defined border, irregular contour, and inhomogeneous hypoechoic mass with posterior sonic attenuation. In summary, sonography was useful in the evaluation of the palpable breast mass in women less than 35 years old. Choreoathetotic sonographic findings might help the differential diagnosis of breast masses

  4. Archtecture of distributed real-time systems

    OpenAIRE

    Wing Leung, Cheuk

    2013-01-01

    CRAFTERS (Constraint and Application Driven Framework for Tailoring Embedded Real-time System) project aims to address the problem of uncertainty and heterogeneity in a distributed system by providing seamless, portable connectivity and middleware. This thesis contributes to the project by investigating the techniques that can be used in a distributed real-time embedded system. The conclusion is that, there is a list of specifications to be meet in order to provide a transparent and real-time...

  5. The real-time price elasticity of electricity

    NARCIS (Netherlands)

    Lijesen, M.G.

    2007-01-01

    The real-time price elasticity of electricity contains important information on the demand response of consumers to the volatility of peak prices. Despite the importance, empirical estimates of the real-time elasticity are hardly available. This paper provides a quantification of the real-time

  6. Implementing Run-Time Evaluation of Distributed Timing Constraints in a Real-Time Environment

    DEFF Research Database (Denmark)

    Kristensen, C. H.; Drejer, N.

    1994-01-01

    In this paper we describe a solution to the problem of implementing run-time evaluation of timing constraints in distributed real-time environments......In this paper we describe a solution to the problem of implementing run-time evaluation of timing constraints in distributed real-time environments...

  7. REAL TIME SYSTEM OPERATIONS 2006-2007

    Energy Technology Data Exchange (ETDEWEB)

    Eto, Joseph H.; Parashar, Manu; Lewis, Nancy Jo

    2008-08-15

    The Real Time System Operations (RTSO) 2006-2007 project focused on two parallel technical tasks: (1) Real-Time Applications of Phasors for Monitoring, Alarming and Control; and (2) Real-Time Voltage Security Assessment (RTVSA) Prototype Tool. The overall goal of the phasor applications project was to accelerate adoption and foster greater use of new, more accurate, time-synchronized phasor measurements by conducting research and prototyping applications on California ISO's phasor platform - Real-Time Dynamics Monitoring System (RTDMS) -- that provide previously unavailable information on the dynamic stability of the grid. Feasibility assessment studies were conducted on potential application of this technology for small-signal stability monitoring, validating/improving existing stability nomograms, conducting frequency response analysis, and obtaining real-time sensitivity information on key metrics to assess grid stress. Based on study findings, prototype applications for real-time visualization and alarming, small-signal stability monitoring, measurement based sensitivity analysis and frequency response assessment were developed, factory- and field-tested at the California ISO and at BPA. The goal of the RTVSA project was to provide California ISO with a prototype voltage security assessment tool that runs in real time within California ISO?s new reliability and congestion management system. CERTS conducted a technical assessment of appropriate algorithms, developed a prototype incorporating state-of-art algorithms (such as the continuation power flow, direct method, boundary orbiting method, and hyperplanes) into a framework most suitable for an operations environment. Based on study findings, a functional specification was prepared, which the California ISO has since used to procure a production-quality tool that is now a part of a suite of advanced computational tools that is used by California ISO for reliability and congestion management.

  8. A study of real-time content marketing : formulating real-time content marketing based on content, search and social media

    OpenAIRE

    Nguyen, Thi Kim Duyen

    2015-01-01

    The primary objective of this research is to understand profoundly the new concept of content marketing – real-time content marketing on the aspect of the digital marketing experts. Particularly, the research will focus on the real-time content marketing theories and how to build real-time content marketing strategy based on content, search and social media. It also finds out how marketers measure and keep track of conversion rates of their real-time content marketing plan. Practically, th...

  9. Budd-chiari syndrome by membranous obstruction of inferior vena cava: comparison of sonography and computed tomography

    International Nuclear Information System (INIS)

    Lee, Dong Ho; Lim, Jae Hoon; Ko, Young Tae; Yoon, Yup; Lim, Joo Won

    1992-01-01

    Membranous obstruction of the hepatic inferior vena cava (MOVC) is one of the common causes of Budd-Chiari syndrome. The aim of this study is to ascertain and compare the characteristic sonographic and CT findings of Budd-Chiari syndrome caused by MOVC. We studied 10 patients of Budd-Chiari syndrome caused by MOVC thorough sonography and CT. MOVC was confirmed by operation and/or inferior vena cavography. The cases included 9 men and one woman. With sonography, IVC obstruction was diagnosed in 9 cases. The cause of IVC obstruction was web in 5 cases and fibrous cord in 3 cases. The cause was unspecified in one case. Obliteration of the hepatic veins and intrahepatic collateral vessels were delineated in 9 cases. With color doppler sonography, the directions of blood flow of the hepatic veins through the intervenous communication were fairly well demonstrated in all 5 cases. With CT, IVC obstruction was diagnosed in 7 cases. The obliteration of the hepatic segment of the IVC were segmental in 6 cases and diffuse in one case. CT demonstrated communicating vessels between the hepatic veins in 3 cases. Furthermore, systemic collateral vessels (azygos and hemiazygos veins, veins along the abdominal wall, and internal mammary veins) were demonstrated in all cases. Liver cirrhosis was combined in all cases and hepatoma developed in 4 cases. Sonography is useful to detect the MOVC and to demonstrate hepatic venous obstruction and intrahepatic collateral vessels. Color doppler sonography is easily performed to show the direction of the blood flow through interconnecting vessels. CT shows the obliterated segment of the IVC clearly and multiple prominent systemic collaterals. In conclusion, Budd-Chiari syndrome caused by MOVC is accurately diagnosed by combined color doppler sonography and CT

  10. The value of intraoperative sonography in low grade glioma surgery.

    Science.gov (United States)

    Petridis, Athanasios K; Anokhin, Maxim; Vavruska, Jan; Mahvash, Mehran; Scholz, Martin

    2015-04-01

    There is a number of different methods to localize a glioma intraoperatively. Neuronavigation, intraoperative MRI, 5-aminolevulinic acid, as well as intraoperative sonography. Every method has its advantages and disadvantages. Low grade gliomas do not show a specific signal with 5-aminolevulinic acid and are difficult to distinguish macroscopically from normal tissue. In the present study we stress out the importance of intraoperative diagnostic ultrasound for localization of low grade gliomas. We retrospectively evaluated the charts and MRIs of 34 patients with low grade gliomas operated in our department from 2011 until December 2014. The efficacy of ultrasound as an intraoperative navigational tool was assessed. In 15 patients ultrasound was used and in 19 not. Only histologically proven low grades gliomas (astrocytomas grade II) were evaluated. In none of the patients where ultrasound (combined with neuronavigation) was used (N=15) to find the tumors, the target was missed, whereas the exclusive use of neuronavigation missed the target in 5 of 19 cases of small subcortical low grade gliomas. Intraoperative ultrasound is an excellent tool in localizing low grade gliomas intraoperatively. It is an inexpensive, real time neuronavigational tool, which overcomes brain shift. Even when identifying the tumors with ultrasound is very reliable, the extend of resection and the decision to remove any residual tumor with the help of ultrasound is at the moment unreliable. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Integrating and Visualizing Tropical Cyclone Data Using the Real Time Mission Monitor

    Science.gov (United States)

    Goodman, H. Michael; Blakeslee, Richard; Conover, Helen; Hall, John; He, Yubin; Regner, Kathryn

    2009-01-01

    The Real Time Mission Monitor (RTMM) is a visualization and information system that fuses multiple Earth science data sources, to enable real time decision-making for airborne and ground validation experiments. Developed at the NASA Marshall Space Flight Center, RTMM is a situational awareness, decision-support system that integrates satellite imagery, radar, surface and airborne instrument data sets, model output parameters, lightning location observations, aircraft navigation data, soundings, and other applicable Earth science data sets. The integration and delivery of this information is made possible using data acquisition systems, network communication links, network server resources, and visualizations through the Google Earth virtual globe application. RTMM is extremely valuable for optimizing individual Earth science airborne field experiments. Flight planners, scientists, and managers appreciate the contributions that RTMM makes to their flight projects. A broad spectrum of interdisciplinary scientists used RTMM during field campaigns including the hurricane-focused 2006 NASA African Monsoon Multidisciplinary Analyses (NAMMA), 2007 NOAA-NASA Aerosonde Hurricane Noel flight, 2007 Tropical Composition, Cloud, and Climate Coupling (TC4), plus a soil moisture (SMAP-VEX) and two arctic research experiments (ARCTAS) in 2008. Improving and evolving RTMM is a continuous process. RTMM recently integrated the Waypoint Planning Tool, a Java-based application that enables aircraft mission scientists to easily develop a pre-mission flight plan through an interactive point-and-click interface. Individual flight legs are automatically calculated "on the fly". The resultant flight plan is then immediately posted to the Google Earth-based RTMM for interested scientists to view the planned flight track and subsequently compare it to the actual real time flight progress. We are planning additional capabilities to RTMM including collaborations with the Jet Propulsion

  12. Application of XML in real-time data warehouse

    Science.gov (United States)

    Zhao, Yanhong; Wang, Beizhan; Liu, Lizhao; Ye, Su

    2009-07-01

    At present, XML is one of the most widely-used technologies of data-describing and data-exchanging, and the needs for real-time data make real-time data warehouse a popular area in the research of data warehouse. What effects can we have if we apply XML technology to the research of real-time data warehouse? XML technology solves many technologic problems which are impossible to be addressed in traditional real-time data warehouse, and realize the integration of OLAP (On-line Analytical Processing) and OLTP (Online transaction processing) environment. Then real-time data warehouse can truly be called "real time".

  13. Upper Abdominal Ultra-Sonography Findings in HIV Patients at ...

    African Journals Online (AJOL)

    Design: A descriptive cross-sectional study. Setting: Kenyatta National Hospital and the Defence Forces Memorial Hospital, Nairobi, Kenya. Subjects: HIV infected patients referred for upper abdominal sonography within the study duration of eight months. Results: Two hundred and seventy three (273) patients were ...

  14. Mixed - mode Operating System for Real - time Performance

    OpenAIRE

    Hasan M. M.; Sultana S.; Foo C.K.

    2017-01-01

    The purpose of the mixed-mode system research is to handle devices with the accuracy of real-time systems and at the same time, having all the benefits and facilities of a matured Graphic User Interface(GUI)operating system which is typicallynon-real-time. This mixed-mode operating system comprising of a real-time portion and a non-real-time portion was studied and implemented to identify the feasibilities and performances in practical applications (in the context of scheduled the real-time e...

  15. Plantar fascia softening in plantar fasciitis with normal B-mode sonography.

    Science.gov (United States)

    Wu, Chueh-Hung; Chen, Wen-Shiang; Wang, Tyng-Guey

    2015-11-01

    To investigate plantar fascia elasticity in patients with typical clinical manifestations of plantar fasciitis but normal plantar fascia morphology on B-mode sonography. Twenty patients with plantar fasciitis (10 unilateral and 10 bilateral) and 30 healthy volunteers, all with normal plantar fascia morphology on B-mode sonography, were included in the study. Plantar fascia elasticity was evaluated by sonoelastographic examination. All sonoelastograms were quantitatively analyzed, and less red pixel intensity was representative of softer tissue. Pixel intensity was compared among unilateral plantar fasciitis patients, bilateral plantar fasciitis patients, and healthy volunteers by one-way ANOVA. A post hoc Scheffé's test was used to identify where the differences occurred. Compared to healthy participants (red pixel intensity: 146.9 ± 9.1), there was significantly less red pixel intensity in the asymptomatic sides of unilateral plantar fasciitis (140.4 ± 7.3, p = 0.01), symptomatic sides of unilateral plantar fasciitis (127.1 ± 7.4, p plantar fasciitis (129.4 ± 7.5, p plantar fascia thickness or green or blue pixel intensity among these groups. Sonoelastography revealed that the plantar fascia is softer in patients with typical clinical manifestations of plantar fasciitis, even if they exhibit no abnormalities on B-mode sonography.

  16. Mixed-mode Operating System for Real-time Performance

    Directory of Open Access Journals (Sweden)

    M.M. Hasan

    2017-11-01

    Full Text Available The purpose of the mixed-mode system research is to handle devices with the accuracy of real-time systems and at the same time, having all the benefits and facilities of a matured Graphic User Interface (GUI operating system which is typically nonreal-time. This mixed-mode operating system comprising of a real-time portion and a non-real-time portion was studied and implemented to identify the feasibilities and performances in practical applications (in the context of scheduled the real-time events. In this research an i8751 microcontroller-based hardware was used to measure the performance of the system in real-time-only as well as non-real-time-only configurations. The real-time portion is an 486DX-40 IBM PC system running under DOS-based realtime kernel and the non-real-time portion is a Pentium III based system running under Windows NT. It was found that mixed-mode systems performed as good as a typical realtime system and in fact, gave many additional benefits such as simplified/modular programming and load tolerance.

  17. Testing of real-time-software

    International Nuclear Information System (INIS)

    Friesland, G.; Ovenhausen, H.

    1975-05-01

    The situation in the area of testing real-time-software is unsatisfactory. During the first phase of the project PROMOTE (prozessorientiertes Modul- und Gesamttestsystem) an analysis of the momentary situation took place, results of which are summarized in the following study about some user interviews and an analysis of relevant literature. 22 users (industry, software-houses, hardware-manufacturers, and institutes) have been interviewed. Discussions were held about reliability of real-time software with special interest to error avoidance, testing, and debugging. Main aims of the analysis of the literature were elaboration of standard terms, comparison of existing test methods and -systems, and the definition of boundaries to related areas. During the further steps of this project some means and techniques will be worked out to systematically test real-time software. (orig.) [de

  18. Validation and Assessment of Multi-GNSS Real-Time Precise Point Positioning in Simulated Kinematic Mode Using IGS Real-Time Service

    Directory of Open Access Journals (Sweden)

    Liang Wang

    2018-02-01

    Full Text Available Precise Point Positioning (PPP is a popular technology for precise applications based on the Global Navigation Satellite System (GNSS. Multi-GNSS combined PPP has become a hot topic in recent years with the development of multiple GNSSs. Meanwhile, with the operation of the real-time service (RTS of the International GNSS Service (IGS agency that provides satellite orbit and clock corrections to broadcast ephemeris, it is possible to obtain the real-time precise products of satellite orbits and clocks and to conduct real-time PPP. In this contribution, the real-time multi-GNSS orbit and clock corrections of the CLK93 product are applied for real-time multi-GNSS PPP processing, and its orbit and clock qualities are investigated, first with a seven-day experiment by comparing them with the final multi-GNSS precise product ‘GBM’ from GFZ. Then, an experiment involving real-time PPP processing for three stations in the Multi-GNSS Experiment (MGEX network with a testing period of two weeks is conducted in order to evaluate the convergence performance of real-time PPP in a simulated kinematic mode. The experimental result shows that real-time PPP can achieve a convergence performance of less than 15 min for an accuracy level of 20 cm. Finally, the real-time data streams from 12 globally distributed IGS/MGEX stations for one month are used to assess and validate the positioning accuracy of real-time multi-GNSS PPP. The results show that the simulated kinematic positioning accuracy achieved by real-time PPP on different stations is about 3.0 to 4.0 cm for the horizontal direction and 5.0 to 7.0 cm for the three-dimensional (3D direction.

  19. Bayesian based design of real-time sensor systems for high-risk indoor contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Sreedharan, Priya [Univ. of California, Berkeley, CA (United States)

    2007-01-01

    The sudden release of toxic contaminants that reach indoor spaces can be hazardousto building occupants. To respond effectively, the contaminant release must be quicklydetected and characterized to determine unobserved parameters, such as release locationand strength. Characterizing the release requires solving an inverse problem. Designinga robust real-time sensor system that solves the inverse problem is challenging becausethe fate and transport of contaminants is complex, sensor information is limited andimperfect, and real-time estimation is computationally constrained.This dissertation uses a system-level approach, based on a Bayes Monte Carloframework, to develop sensor-system design concepts and methods. I describe threeinvestigations that explore complex relationships among sensors, network architecture,interpretation algorithms, and system performance. The investigations use data obtainedfrom tracer gas experiments conducted in a real building. The influence of individual sensor characteristics on the sensor-system performance for binary-type contaminant sensors is analyzed. Performance tradeoffs among sensor accuracy, threshold level and response time are identified; these attributes could not be inferred without a system-level analysis. For example, more accurate but slower sensors are found to outperform less accurate but faster sensors. Secondly, I investigate how the sensor-system performance can be understood in terms of contaminant transport processes and the model representation that is used to solve the inverse problem. The determination of release location and mass are shown to be related to and constrained by transport and mixing time scales. These time scales explain performance differences among different sensor networks. For example, the effect of longer sensor response times is comparably less for releases with longer mixing time scales. The third investigation explores how information fusion from heterogeneous sensors may improve the sensor

  20. The FERMI-Elettra distributed real-time framework

    International Nuclear Information System (INIS)

    Pivetta, L.; Gaio, G.; Passuello, R.; Scalamera, G.

    2012-01-01

    FERMI-Elettra is a Free Electron Laser (FEL) based on a 1.5 GeV linac. The pulsed operation of the accelerator and the necessity to characterize and control each electron bunch requires synchronous acquisition of the beam diagnostics together with the ability to drive actuators in real-time at the linac repetition rate. The Adeos/Xenomai real-time extensions have been adopted in order to add real-time capabilities to the Linux based control system computers running the Tango software. A software communication protocol based on Gigabit Ethernet and known as Network Reflective Memory (NRM) has been developed to implement a shared memory across the whole control system, allowing computers to communicate in real-time. The NRM architecture, the real-time performance and the integration in the control system are described. (authors)

  1. Real-time video quality monitoring

    Science.gov (United States)

    Liu, Tao; Narvekar, Niranjan; Wang, Beibei; Ding, Ran; Zou, Dekun; Cash, Glenn; Bhagavathy, Sitaram; Bloom, Jeffrey

    2011-12-01

    The ITU-T Recommendation G.1070 is a standardized opinion model for video telephony applications that uses video bitrate, frame rate, and packet-loss rate to measure the video quality. However, this model was original designed as an offline quality planning tool. It cannot be directly used for quality monitoring since the above three input parameters are not readily available within a network or at the decoder. And there is a great room for the performance improvement of this quality metric. In this article, we present a real-time video quality monitoring solution based on this Recommendation. We first propose a scheme to efficiently estimate the three parameters from video bitstreams, so that it can be used as a real-time video quality monitoring tool. Furthermore, an enhanced algorithm based on the G.1070 model that provides more accurate quality prediction is proposed. Finally, to use this metric in real-world applications, we present an example emerging application of real-time quality measurement to the management of transmitted videos, especially those delivered to mobile devices.

  2. Two- and three-dimensional transvaginal ultrasound with power Doppler angiography and gel infusion sonography for diagnosis of endometrial malignancy.

    Science.gov (United States)

    Dueholm, M; Christensen, J W; Rydbjerg, S; Hansen, E S; Ørtoft, G

    2015-06-01

    To evaluate the diagnostic efficiency of two-dimensional (2D) and three-dimensional (3D) transvaginal ultrasonography, power Doppler angiography (PDA) and gel infusion sonography (GIS) at offline analysis for recognition of malignant endometrium compared with real-time evaluation during scanning, and to determine optimal image parameters at 3D analysis. One hundred and sixty-nine consecutive women with postmenopausal bleeding and endometrial thickness ≥ 5 mm underwent systematic evaluation of endometrial pattern on 2D imaging, and 2D videoclips and 3D volumes were later analyzed offline. Histopathological findings at hysteroscopy or hysterectomy were used as the reference standard. The efficiency of the different techniques for diagnosis of malignancy was calculated and compared. 3D image parameters, endometrial volume and 3D vascular indices were assessed. Optimal 3D image parameters were transformed by logistic regression into a risk of endometrial cancer (REC) score, including scores for body mass index, endometrial thickness and endometrial morphology at gray-scale and PDA and GIS. Offline 2D and 3D analysis were equivalent, but had lower diagnostic performance compared with real-time evaluation during scanning. Their diagnostic performance was not markedly improved by the addition of PDA or GIS, but their efficiency was comparable with that of real-time 2D-GIS in offline examinations of good image quality. On logistic regression, the 3D parameters from the REC-score system had the highest diagnostic efficiency. The area under the curve of the REC-score system at 3D-GIS (0.89) was not improved by inclusion of vascular indices or endometrial volume calculations. Real-time evaluation during scanning is most efficient, but offline 2D and 3D analysis is useful for prediction of endometrial cancer when good image quality can be obtained. The diagnostic efficiency at 3D analysis may be improved by use of REC-scoring systems, without the need for calculation of

  3. Phylloedes tumor of breast: findings at mammography, sonography and color Doppler imaging

    International Nuclear Information System (INIS)

    Park, Kun Choon; Ahn, Sei Hyun; Kim, Young Hwan; Choi, Hye Yong; Baek, Seung Yon; Yoon, Jeong Hyun

    1994-01-01

    The phylloides tumor of the breast is rare. the purposes of this study were to find the characteristic findings at mammography, sonography, and color Doppler imaging and to evaluate the usefulness of color Doppler study as an additional modality in the diagnosis of phylloides tumor and differentiation between benign and malignant varieties. Eight cases, who were pathologically proven as pylloides tumors, were retrospectively studied. The findings at histologic examination suggested benign in five, malignantin two, and borderline in one. We analyzed the mammograms of all eight patients and sonogram and color Doppler images of four patients. Phylloides tumors were seen as dense masses with lobulated margins in mammograms. On sonography, they showed relatively well-defined masses with in homogenous internal echo pattern and central echogenic areas. They were characterized by the presence of arterial and venous flows in the center and periphery of the lesion on color Doppler imaging and spectral analysis. We conclude that mammographic, sonographic and even color Doppler findings are not predictive of benign or malignant nature of the phylloides tumor. However, mammography and sonography with color Doppler interrogation are helpful in the diagnosis of phylloides tumor

  4. Heterogeneous Embedded Real-Time Systems Environment

    Science.gov (United States)

    2003-12-01

    AFRL-IF-RS-TR-2003-290 Final Technical Report December 2003 HETEROGENEOUS EMBEDDED REAL - TIME SYSTEMS ENVIRONMENT Integrated...HETEROGENEOUS EMBEDDED REAL - TIME SYSTEMS ENVIRONMENT 6. AUTHOR(S) Cosmo Castellano and James Graham 5. FUNDING NUMBERS C - F30602-97-C-0259

  5. Validation of color Doppler sonography for evaluating relative displacement between the flexor tendon and subsynovial connective tissue.

    Science.gov (United States)

    Tat, Jimmy; Kociolek, Aaron M; Keir, Peter J

    2015-04-01

    A common pathologic finding in carpal tunnel syndrome is fibrosis and thickening of the subsynovial connective tissue. This finding suggests an etiology of excessive shear forces, with relative longitudinal displacement between the flexor tendon and adjacent subsynovial connective tissue. The purpose of this study was to validate color Doppler sonography for measurement of tendon displacement over time. Eight unmatched fresh frozen cadaver arms were used to evaluate color Doppler sonography for measurement of tendon displacement. The middle flexor digitorum superficialis tendon was moved through a physiologic excursion of 20 mm at 3 different tendon velocities (50, 100, and 150 mm/s). We found that color Doppler sonography provided accurate measurement of tendon displacement, with absolute errors of -0.05 mm (50 mm/s), -1.24 mm (100 mm/s), and -2.36 mm (150 mm/s) on average throughout the tendon excursion range. Evaluating relative displacement between the tendon and subsynovial connective tissue during finger flexion-extension movements also offered insight into the gliding mechanism of the subsynovial connective tissue. During flexion, we observed a curvilinear increase in relative displacement, with greater differential motion at the end range of displacement, likely due to the sequential stretch of the fibrils between successive layers of the subsynovial connective tissue. In extension, there was a linear return in relative displacement, suggesting a different unloading mechanism characterized by uniform relaxation of fibrils. We demonstrated the validity of color Doppler displacement for use in the evaluation of relative motion. Color Doppler sonography is useful in our understanding of the behavior of the subsynovial connective tissue during tendon excursion, which may elucidate the role of finger motion in the etiology of shear injury. © 2015 by the American Institute of Ultrasound in Medicine.

  6. Temporal Proof Methodologies for Real-Time Systems,

    Science.gov (United States)

    1990-09-01

    real time systems that communicate either through shared variables or by message passing and real time issues such as time-outs, process priorities (interrupts) and process scheduling. The authors exhibit two styles for the specification of real - time systems . While the first approach uses bounded versions of temporal operators the second approach allows explicit references to time through a special clock variable. Corresponding to two styles of specification the authors present and compare two fundamentally different proof

  7. Real-time communication protocols: an overview

    NARCIS (Netherlands)

    Hanssen, F.T.Y.; Jansen, P.G.

    2003-01-01

    This paper describes several existing data link layer protocols that provide real-time capabilities on wired networks, focusing on token-ring and Carrier Sense Multiple Access based networks. Existing modifications to provide better real-time capabilities and performance are also described. Finally

  8. Self-Organization in Embedded Real-Time Systems

    CERN Document Server

    Brinkschulte, Uwe; Rettberg, Achim

    2013-01-01

    This book describes the emerging field of self-organizing, multicore, distributed and real-time embedded systems.  Self-organization of both hardware and software can be a key technique to handle the growing complexity of modern computing systems. Distributed systems running hundreds of tasks on dozens of processors, each equipped with multiple cores, requires self-organization principles to ensure efficient and reliable operation. This book addresses various, so-called Self-X features such as self-configuration, self-optimization, self-adaptation, self-healing and self-protection. Presents open components for embedded real-time adaptive and self-organizing applications; Describes innovative techniques in: scheduling, memory management, quality of service, communications supporting organic real-time applications; Covers multi-/many-core embedded systems supporting real-time adaptive systems and power-aware, adaptive hardware and software systems; Includes case studies of open embedded real-time self-organizi...

  9. Real-time systems scheduling fundamentals

    CERN Document Server

    Chetto, Maryline

    2014-01-01

    Real-time systems are used in a wide range of applications, including control, sensing, multimedia, etc.  Scheduling is a central problem for these computing/communication systems since responsible of software execution in a timely manner. This book provides state of knowledge in this domain with special emphasis on the key results obtained within the last decade. This book addresses foundations as well as the latest advances and findings in Real-Time Scheduling, giving all references to important papers. But nevertheless the chapters will be short and not overloaded with confusing details.

  10. Real-time specifications

    DEFF Research Database (Denmark)

    David, A.; Larsen, K.G.; Legay, A.

    2015-01-01

    A specification theory combines notions of specifications and implementations with a satisfaction relation, a refinement relation, and a set of operators supporting stepwise design. We develop a specification framework for real-time systems using Timed I/O Automata as the specification formalism......, with the semantics expressed in terms of Timed I/O Transition Systems. We provide constructs for refinement, consistency checking, logical and structural composition, and quotient of specifications-all indispensable ingredients of a compositional design methodology. The theory is implemented in the new tool Ecdar...

  11. On Real-Time Systems Using Local Area Networks.

    Science.gov (United States)

    1987-07-01

    87-35 July, 1987 CS-TR-1892 On Real - Time Systems Using Local Area Networks*I VShem-Tov Levi Department of Computer Science Satish K. Tripathit...1892 On Real - Time Systems Using Local Area Networks* Shem-Tov Levi Department of Computer Science Satish K. Tripathit Department of Computer Science...constraints and the clock systems that feed the time to real - time systems . A model for real-time system based on LAN communication is presented in

  12. Approaching near real-time biosensing: microfluidic microsphere based biosensor for real-time analyte detection.

    Science.gov (United States)

    Cohen, Noa; Sabhachandani, Pooja; Golberg, Alexander; Konry, Tania

    2015-04-15

    In this study we describe a simple lab-on-a-chip (LOC) biosensor approach utilizing well mixed microfluidic device and a microsphere-based assay capable of performing near real-time diagnostics of clinically relevant analytes such cytokines and antibodies. We were able to overcome the adsorption kinetics reaction rate-limiting mechanism, which is diffusion-controlled in standard immunoassays, by introducing the microsphere-based assay into well-mixed yet simple microfluidic device with turbulent flow profiles in the reaction regions. The integrated microsphere-based LOC device performs dynamic detection of the analyte in minimal amount of biological specimen by continuously sampling micro-liter volumes of sample per minute to detect dynamic changes in target analyte concentration. Furthermore we developed a mathematical model for the well-mixed reaction to describe the near real time detection mechanism observed in the developed LOC method. To demonstrate the specificity and sensitivity of the developed real time monitoring LOC approach, we applied the device for clinically relevant analytes: Tumor Necrosis Factor (TNF)-α cytokine and its clinically used inhibitor, anti-TNF-α antibody. Based on the reported results herein, the developed LOC device provides continuous sensitive and specific near real-time monitoring method for analytes such as cytokines and antibodies, reduces reagent volumes by nearly three orders of magnitude as well as eliminates the washing steps required by standard immunoassays. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Mixed-mode Operating System for Real-time Performance

    OpenAIRE

    M.M. Hasan; S. Sultana; C.K. Foo

    2017-01-01

    The purpose of the mixed-mode system research is to handle devices with the accuracy of real-time systems and at the same time, having all the benefits and facilities of a matured Graphic User Interface (GUI) operating system which is typically nonreal-time. This mixed-mode operating system comprising of a real-time portion and a non-real-time portion was studied and implemented to identify the feasibilities and performances in practical applications (in the context of scheduled the real-time...

  14. Demonstration of array eddy current technology for real-time monitoring of laser powder bed fusion additive manufacturing process

    Science.gov (United States)

    Todorov, Evgueni; Boulware, Paul; Gaah, Kingsley

    2018-03-01

    Nondestructive evaluation (NDE) at various fabrication stages is required to assure quality of feedstock and solid builds. Industry efforts are shifting towards solutions that can provide real-time monitoring of additive manufacturing (AM) fabrication process layer-by-layer while the component is being built to reduce or eliminate dependence on post-process inspection. Array eddy current (AEC), electromagnetic NDE technique was developed and implemented to directly scan the component without physical contact with the powder and fused layer surfaces at elevated temperatures inside a LPBF chamber. The technique can detect discontinuities, surface irregularities, and undesirable metallurgical phase transformations in magnetic and nonmagnetic conductive materials used for laser fusion. The AEC hardware and software were integrated with the L-PBF test bed. Two layer-by-layer tests of Inconel 625 coupons with AM built discontinuities and lack of fusion were conducted inside the L-PBF chamber. The AEC technology demonstrated excellent sensitivity to seeded, natural surface, and near-surface-embedded discontinuities, while also detecting surface topography. The data was acquired and imaged in a layer-by-layer sequence demonstrating the real-time monitoring capabilities of this new technology.

  15. Language Lateralization in Children Using Functional Transcranial Doppler Sonography

    Science.gov (United States)

    Haag, Anja; Moeller, Nicola; Knake, Susanne; Hermsen, Anke; Oertel, Wolfgang H.; Rosenow, Felix; Hamer, Hajo M.

    2010-01-01

    Aim: Language lateralization with functional transcranial Doppler sonography (fTCD) and lexical word generation has been shown to have high concordance with the Wada test and functional magnetic resonance imaging in adults. We evaluated a nonlexical paradigm to determine language dominance in children. Method: In 23 right-handed children (12…

  16. Linux real-time framework for fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Neto, Andre [Associacao Euratom-IST, Instituto de Plasmas e Fusao Nuclear, Av. Rovisco Pais, 1049-001 Lisboa (Portugal)], E-mail: andre.neto@cfn.ist.utl.pt; Sartori, Filippo; Piccolo, Fabio [Euratom-UKAEA, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Barbalace, Antonio [Euratom-ENEA Association, Consorzio RFX, 35127 Padova (Italy); Vitelli, Riccardo [Dipartimento di Informatica, Sistemi e Produzione, Universita di Roma, Tor Vergata, Via del Politecnico 1-00133, Roma (Italy); Fernandes, Horacio [Associacao Euratom-IST, Instituto de Plasmas e Fusao Nuclear, Av. Rovisco Pais, 1049-001 Lisboa (Portugal)

    2009-06-15

    A new framework for the development and execution of real-time codes is currently being developed and commissioned at JET. The foundations of the system are Linux, the Real Time Application Interface (RTAI) and a wise exploitation of the new i386 multi-core processors technology. The driving motivation was the need to find a real-time operating system for the i386 platform able to satisfy JET Vertical Stabilisation Enhancement project requirements: 50 {mu}s cycle time. Even if the initial choice was the VxWorks operating system, it was decided to explore an open source alternative, mostly because of the costs involved in the commercial product. The work started with the definition of a precise set of requirements and milestones to achieve: Linux distribution and kernel versions to be used for the real-time operating system; complete characterization of the Linux/RTAI real-time capabilities; exploitation of the multi-core technology; implementation of all the required and missing features; commissioning of the system. Latency and jitter measurements were compared for Linux and RTAI in both user and kernel-space. The best results were attained using the RTAI kernel solution where the time to reschedule a real-time task after an external interrupt is of 2.35 {+-} 0.35 {mu}s. In order to run the real-time codes in the kernel-space, a solution to provide user-space functionalities to the kernel modules had to be designed. This novel work provided the most common functions from the standard C library and transparent interaction with files and sockets to the kernel real-time modules. Kernel C++ support was also tested, further developed and integrated in the framework. The work has produced very convincing results so far: complete isolation of the processors assigned to real-time from the Linux non real-time activities, high level of stability over several days of benchmarking operations and values well below 3 {mu}s for task rescheduling after external interrupt. From

  17. Linux real-time framework for fusion devices

    International Nuclear Information System (INIS)

    Neto, Andre; Sartori, Filippo; Piccolo, Fabio; Barbalace, Antonio; Vitelli, Riccardo; Fernandes, Horacio

    2009-01-01

    A new framework for the development and execution of real-time codes is currently being developed and commissioned at JET. The foundations of the system are Linux, the Real Time Application Interface (RTAI) and a wise exploitation of the new i386 multi-core processors technology. The driving motivation was the need to find a real-time operating system for the i386 platform able to satisfy JET Vertical Stabilisation Enhancement project requirements: 50 μs cycle time. Even if the initial choice was the VxWorks operating system, it was decided to explore an open source alternative, mostly because of the costs involved in the commercial product. The work started with the definition of a precise set of requirements and milestones to achieve: Linux distribution and kernel versions to be used for the real-time operating system; complete characterization of the Linux/RTAI real-time capabilities; exploitation of the multi-core technology; implementation of all the required and missing features; commissioning of the system. Latency and jitter measurements were compared for Linux and RTAI in both user and kernel-space. The best results were attained using the RTAI kernel solution where the time to reschedule a real-time task after an external interrupt is of 2.35 ± 0.35 μs. In order to run the real-time codes in the kernel-space, a solution to provide user-space functionalities to the kernel modules had to be designed. This novel work provided the most common functions from the standard C library and transparent interaction with files and sockets to the kernel real-time modules. Kernel C++ support was also tested, further developed and integrated in the framework. The work has produced very convincing results so far: complete isolation of the processors assigned to real-time from the Linux non real-time activities, high level of stability over several days of benchmarking operations and values well below 3 μs for task rescheduling after external interrupt. From being the

  18. Static Schedulers for Embedded Real-Time Systems

    Science.gov (United States)

    1989-12-01

    Because of the need for having efficient scheduling algorithms in large scale real time systems , software engineers put a lot of effort on developing...provide static schedulers for he Embedded Real Time Systems with single processor using Ada programming language. The independent nonpreemptable...support the Computer Aided Rapid Prototyping for Embedded Real Time Systems so that we determine whether the system, as designed, meets the required

  19. Real-time motional Stark effect in jet

    International Nuclear Information System (INIS)

    Alves, D.; Stephen, A.; Hawkes, N.; Dalley, S.; Goodyear, A.; Felton, R.; Joffrin, E.; Fernandes, H.

    2004-01-01

    The increasing importance of real-time measurements and control systems in JET experiments, regarding e.g. Internal Transport Barrier (ITB) and q-profile control, has motivated the development of a real-time motional Stark effect (MSE) system. The MSE diagnostic allows the measurement of local magnetic fields in different locations along the neutral beam path providing, therefore, local measurement of the current and q-profiles. Recently in JET, an upgrade of the MSE diagnostic has been implemented, incorporating a totally new system which allows the use of this diagnostic as a real-time control tool as well as an extended data source for off-line analysis. This paper will briefly describe the technical features of the real-time diagnostic with main focus on the system architecture, which consists of a VME crate hosting three PowerPC processor boards and a fast ADC, all connected via Front Panel Data Port (FPDP). The DSP algorithm implements a lockin-amplifier required to demodulate the JET MSE signals. Some applications for the system will be covered such as: feeding the real-time equilibrium reconstruction code (EQUINOX) and allowing the full coverage analysis of the Neutral Beam time window. A brief comparison between the real-time MSE analysis and the off-line analysis will also be presented

  20. Scala for Real-Time Systems?

    DEFF Research Database (Denmark)

    Schoeberl, Martin

    2015-01-01

    Java served well as a general-purpose language. However, during its two decades of constant change it has gotten some weight and legacy in the language syntax and the libraries. Furthermore, Java's success for real-time systems is mediocre. Scala is a modern object-oriented and functional language...... with interesting new features. Although a new language, it executes on a Java virtual machine, reusing that technology. This paper explores Scala as language for future real-time systems....

  1. Towards exascale real-time RFI mitigation

    NARCIS (Netherlands)

    van Nieuwpoort, R.V.

    2016-01-01

    We describe the design and implementation of an extremely scalable real-time RFI mitigation method, based on the offline AOFlagger. All algorithms scale linearly in the number of samples. We describe how we implemented the flagger in the LOFAR real-time pipeline, on both CPUs and GPUs. Additionally,

  2. Time-Optimal Real-Time Test Case Generation using UPPAAL

    DEFF Research Database (Denmark)

    Hessel, Anders; Larsen, Kim Guldstrand; Nielsen, Brian

    2004-01-01

    Testing is the primary software validation technique used by industry today, but remains ad hoc, error prone, and very expensive. A promising improvement is to automatically generate test cases from formal models of the system under test. We demonstrate how to automatically generate real...... test purposes or generated automatically from various coverage criteria of the model.......-time conformance test cases from timed automata specifications. Specifically we demonstrate how to fficiently generate real-time test cases with optimal execution time i.e test cases that are the fastest possible to execute. Our technique allows time optimal test cases to be generated using manually formulated...

  3. FUSE: a profit maximization approach for functional summarization of biological networks.

    Science.gov (United States)

    Seah, Boon-Siew; Bhowmick, Sourav S; Dewey, C Forbes; Yu, Hanry

    2012-03-21

    The availability of large-scale curated protein interaction datasets has given rise to the opportunity to investigate higher level organization and modularity within the protein interaction network (PPI) using graph theoretic analysis. Despite the recent progress, systems level analysis of PPIS remains a daunting task as it is challenging to make sense out of the deluge of high-dimensional interaction data. Specifically, techniques that automatically abstract and summarize PPIS at multiple resolutions to provide high level views of its functional landscape are still lacking. We present a novel data-driven and generic algorithm called FUSE (Functional Summary Generator) that generates functional maps of a PPI at different levels of organization, from broad process-process level interactions to in-depth complex-complex level interactions, through a pro t maximization approach that exploits Minimum Description Length (MDL) principle to maximize information gain of the summary graph while satisfying the level of detail constraint. We evaluate the performance of FUSE on several real-world PPIS. We also compare FUSE to state-of-the-art graph clustering methods with GO term enrichment by constructing the biological process landscape of the PPIS. Using AD network as our case study, we further demonstrate the ability of FUSE to quickly summarize the network and identify many different processes and complexes that regulate it. Finally, we study the higher-order connectivity of the human PPI. By simultaneously evaluating interaction and annotation data, FUSE abstracts higher-order interaction maps by reducing the details of the underlying PPI to form a functional summary graph of interconnected functional clusters. Our results demonstrate its effectiveness and superiority over state-of-the-art graph clustering methods with GO term enrichment.

  4. Performance evaluation of near-real-time accounting systems

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Examples are given illustrating the application of near-real-time accounting concepts and principles to actual nuclear facilities. Experience with prototypical systems at the AGNS reprocessing plant and the Los Alamos plutonium facility is described using examples of actual data to illustrate the performance and effectiveness of near-real-time systems. The purpose of the session is to enable participants to: (1) identify the major components of near-real-time accounting systems; (2) describe qualitatively the advantages, limitations, and performance of such systems in real nuclear facilities; (3) identify process and facility design characteristics that affect the performance of near-real-time systems; and (4) describe qualitatively the steps necessary to implement a near-real-time accounting and control system in a nuclear facility

  5. Open-access transvaginal sonography in women of reproductive age with abnormal vaginal bleeding: a descriptive study in general practice

    NARCIS (Netherlands)

    de Vries, Corlien J. H.; Wieringa-de Waard, Margreet; Bindels, Patrick J. E.; Ankum, Willem M.

    2011-01-01

    Diagnostic ultrasonography is used by GPs in approximately 10% of patients of reproductive age with abnormal vaginal bleeding. Transvaginal sonography is recommended as a first-line diagnostic instrument for assessing uterine pathology. To assess if findings resulting from open-access sonography

  6. Distributed Issues for Ada Real-Time Systems

    Science.gov (United States)

    1990-07-23

    NUMBERS Distributed Issues for Ada Real - Time Systems MDA 903-87- C- 0056 S. AUTHOR(S) Thomas E. Griest 7. PERFORMING ORGANiZATION NAME(S) AND ADORESS(ES) 8...considerations. I Adding to the problem of distributed real - time systems is the issue of maintaining a common sense of time among all of the processors...because -omeone is waiting for the final output of a very large set of computations. However in real - time systems , consistent meeting of short-term

  7. Design Specifications for Adaptive Real-Time Systems

    Science.gov (United States)

    1991-12-01

    TICfl \\ E CT E Design Specifications for JAN’\\ 1992 Adaptive Real - Time Systems fl Randall W. Lichota U, Alice H. Muntz - December 1991 \\ \\\\/ 0 / r...268-2056 Technical Report CMU/SEI-91-TR-20 ESD-91-TR-20 December 1991 Design Specifications for Adaptive Real - Time Systems Randall W. Lichota Hughes...Design Specifications for Adaptive Real - Time Systems Abstract: The design specification method described in this report treats a software

  8. Design Recovery Technology for Real-Time Systems.

    Science.gov (United States)

    1995-10-01

    RL-TR-95-208 Final Technical Report October 1995 DESIGN RECOVERY TECHNOLOGY FOR REAL TIME SYSTEMS The MITRE Corporation Lester J. Holtzblatt...92 - Jan 95 4. TTTLE AND SUBTITLE DESIGN RECOVERY TECHNOLOGY FOR REAL - TIME SYSTEMS 6. AUTHOR(S) Lester J. Holtzblatt, Richard Piazza, and Susan...behavior of real - time systems in general, our initial efforts have centered on recovering this information from one system in particular, the Modular

  9. Pseudoaneurysm of the posterior circumflex humeral artery diagnosed by sonography

    DEFF Research Database (Denmark)

    Damgaard, Bodil; Court-Payen, Michel; Larsen, Lone

    2009-01-01

    with a painless, nonpulsatile mass in the posterior shoulder region and was suspected of a malignant soft-tissue tumor. Sonography, including power Doppler imaging, demonstrated a pseudoaneurysm, with the intralesional blood-filled cavity developed from the posterior circumflex humeral artery. The diagnosis...

  10. [Real time 3D echocardiography

    Science.gov (United States)

    Bauer, F.; Shiota, T.; Thomas, J. D.

    2001-01-01

    Three-dimensional representation of the heart is an old concern. Usually, 3D reconstruction of the cardiac mass is made by successive acquisition of 2D sections, the spatial localisation and orientation of which require complex guiding systems. More recently, the concept of volumetric acquisition has been introduced. A matricial emitter-receiver probe complex with parallel data processing provides instantaneous of a pyramidal 64 degrees x 64 degrees volume. The image is restituted in real time and is composed of 3 planes (planes B and C) which can be displaced in all spatial directions at any time during acquisition. The flexibility of this system of acquisition allows volume and mass measurement with greater accuracy and reproducibility, limiting inter-observer variability. Free navigation of the planes of investigation allows reconstruction for qualitative and quantitative analysis of valvular heart disease and other pathologies. Although real time 3D echocardiography is ready for clinical usage, some improvements are still necessary to improve its conviviality. Then real time 3D echocardiography could be the essential tool for understanding, diagnosis and management of patients.

  11. Real-time communication for distributed plasma control systems

    Energy Technology Data Exchange (ETDEWEB)

    Luchetta, A. [Consorzio RFX, Associazione Euratom-ENEA sulla Fusione, Corso Stati Uniti 4, Padova 35127 (Italy)], E-mail: adriano.luchetta@igi.cnr.it; Barbalace, A.; Manduchi, G.; Soppelsa, A.; Taliercio, C. [Consorzio RFX, Associazione Euratom-ENEA sulla Fusione, Corso Stati Uniti 4, Padova 35127 (Italy)

    2008-04-15

    Real-time control applications will benefit in the near future from the enhanced performance provided by multi-core processor architectures. Nevertheless real-time communication will continue to be critical in distributed plasma control systems where the plant under control typically is distributed over a wide area. At RFX-mod real-time communication is crucial for hard real-time plasma control, due to the distributed architecture of the system, which consists of several VMEbus stations. The system runs under VxWorks and uses Gigabit Ethernet for sub-millisecond real-time communication. To optimize communication in the system, a set of detailed measurements has been carried out on the target platforms (Motorola MVME5100 and MVME5500) using either the VxWorks User Datagram Protocol (UDP) stack or raw communication based on the data link layer. Measurements have been carried out also under Linux, using its UDP stack or, in alternative, RTnet, an open source hard real-time network protocol stack. RTnet runs under Xenomai or RTAI, two popular real-time extensions based on the Linux kernel. The paper reports on the measurements carried out and compares the results, showing that the performance obtained by using open source code is suitable for sub-millisecond real-time communication in plasma control.

  12. Real-time quasi-3D tomographic reconstruction

    Science.gov (United States)

    Buurlage, Jan-Willem; Kohr, Holger; Palenstijn, Willem Jan; Joost Batenburg, K.

    2018-06-01

    Developments in acquisition technology and a growing need for time-resolved experiments pose great computational challenges in tomography. In addition, access to reconstructions in real time is a highly demanded feature but has so far been out of reach. We show that by exploiting the mathematical properties of filtered backprojection-type methods, having access to real-time reconstructions of arbitrarily oriented slices becomes feasible. Furthermore, we present , software for visualization and on-demand reconstruction of slices. A user of can interactively shift and rotate slices in a GUI, while the software updates the slice in real time. For certain use cases, the possibility to study arbitrarily oriented slices in real time directly from the measured data provides sufficient visual and quantitative insight. Two such applications are discussed in this article.

  13. Contributions of scintigraphy and sonography to the diagnosis of traumatic splenic lesions in children

    International Nuclear Information System (INIS)

    Soucy, J.P.; Danais, S.; Filiatrault, D.; Lamoureux, J.; Lamoureux, F.

    1984-01-01

    20 children who were sent to the Nuclear Medicine and Sonography services for evaluation of the spleen in the context of a history of abdominal trauma were studied. All but one of the children were treated conservately, the exception having had on emergency renal procedure performed for renal rupture. The working diagnosis, based on the clinical that of splenic trauma in all cases. The result show a sensitivity of 90% (2 false negatives) for scintigraphy, and of 30% (14 false negatives) for sonography for the non-invasive diagnosis of splenic trauma in children [fr

  14. Contributions of scintigraphy and sonography to the diagnosis of traumatic splenic lesions in children

    Energy Technology Data Exchange (ETDEWEB)

    Soucy, J.P.; Danais, S.; Filiatrault, D.; Lamoureux, J.; Lamoureux, F. (Hopital Sainte-Justine, Montreal (Canada))

    1984-01-01

    20 children who were sent to the Nuclear Medicine and Sonography services for evaluation of the spleen in the context of a history of abdominal trauma were studied. All but one of the children were treated conservately, the exception having had on emergency renal procedure performed for renal rupture. The working diagnosis, based on the clinical, was that of splenic trauma in all cases. The results show a sensitivity of 90% (2 false negatives) for scintigraphy, and of 30% (14 false negatives) for sonography for the non-invasive diagnosis of splenic trauma in children.

  15. Top ten pitfalls to avoid when performing musculoskeletal sonography: What you should know before entering the examination room

    International Nuclear Information System (INIS)

    Arend, Carlos Frederico

    2013-01-01

    Sonography has been used successfully to evaluate a number of musculoskeletal disorders. The method is operator dependent and familiarity with sonographic pitfalls greatly improves diagnostic accuracy and helps to optimize management. In this article, we discuss ten common pitfalls which can become a source of confusion and misdiagnosis in musculoskeletal sonography

  16. An algorithm for learning real-time automata

    NARCIS (Netherlands)

    Verwer, S.E.; De Weerdt, M.M.; Witteveen, C.

    2007-01-01

    We describe an algorithm for learning simple timed automata, known as real-time automata. The transitions of real-time automata can have a temporal constraint on the time of occurrence of the current symbol relative to the previous symbol. The learning algorithm is similar to the redblue fringe

  17. Exploding metallic fuse physics experiments

    International Nuclear Information System (INIS)

    Goforth, J.H.; Hackett, K.E.; Lindemuth, I.R.; Lopez, E.A.; McCullough, W.F.; Dona, H.; Reinovsky, R.E.

    1986-01-01

    The ultimate practicality of inductive pulse compression systems as drivers for energetic plasma implosions hinges on the development of a suitable opening switch capable of interrupting tons of megamp currents in time scales of a few hundred nanoseconds while withstanding L(dI/dt) voltages of a megavolt or more. 1. Exploding metallic foils (fuses) are a candidate for switching elements in the inductive store pulsed power systems used in the Los Alamos and Air Force Weapons Laboratory foil implosion X-ray source generation programs. To verify or modify new theoretical and computational predictions about the electrical and hydrodynamic behavior of exploding metallic foils used as fuses. The authors have initiated a new series of small scale capacitor bank driven fuse experiments. The experiments represent an extension of previous experiments, but in the new series a foil geometry more amenable to theoretical and computational analysis is used. The metallic foil (aluminum or copper) is laminated between two thin layers of insulating material (mylar or kaptan). Adjacent to one layer of insulation is a much heavier backing insulator (polyethylene) whereas air is adjacent to the other layer. Because of the differing masses on the two sides of the foil, the foil expansion and hydrodynamic motion is essentially one-sided and the layer of insulation on the expanding side becomes a readily-characterizable ''flyer'' which provides a controlled amount of hydrodynamic tamping. In addition to the usual voltage, current, and dI/dt electrical measurements, time-resolved spectrometer measurements are used to determine the temperature of the expanding metallic foil. Post-shot examination of the flyer and the insulation impacted by the flyer gives insight into the experimental behavior

  18. De toekomst van Real Time Intelligence

    NARCIS (Netherlands)

    Broek, J. van den; Berg, C.H. van den

    2013-01-01

    Al direct vanaf de start van de Nationale Politie is gewerkt aan het opzetten van tien real-time intelligence centra in Nederland. Van daaruit worden 24 uur per dag en zeven dagen in de week agenten op straat actief ondersteund met real-time informatie bij de melding waar ze op af gaan. In de visie

  19. Real-Time Parameter Identification

    Data.gov (United States)

    National Aeronautics and Space Administration — Armstrong researchers have implemented in the control room a technique for estimating in real time the aerodynamic parameters that describe the stability and control...

  20. Real time process algebra with time-dependent conditions

    NARCIS (Netherlands)

    Baeten, J.C.M.; Middelburg, C.A.

    We extend the main real time version of ACP presented in [6] with conditionals in which the condition depends on time. This extension facilitates flexible dependence of proccess behaviour on initialization time. We show that the conditions concerned generalize the conditions introduced earlier

  1. Compiling models into real-time systems

    International Nuclear Information System (INIS)

    Dormoy, J.L.; Cherriaux, F.; Ancelin, J.

    1992-08-01

    This paper presents an architecture for building real-time systems from models, and model-compiling techniques. This has been applied for building a real-time model-based monitoring system for nuclear plants, called KSE, which is currently being used in two plants in France. We describe how we used various artificial intelligence techniques for building it: a model-based approach, a logical model of its operation, a declarative implementation of these models, and original knowledge-compiling techniques for automatically generating the real-time expert system from those models. Some of those techniques have just been borrowed from the literature, but we had to modify or invent other techniques which simply did not exist. We also discuss two important problems, which are often underestimated in the artificial intelligence literature: size, and errors. Our architecture, which could be used in other applications, combines the advantages of the model-based approach with the efficiency requirements of real-time applications, while in general model-based approaches present serious drawbacks on this point

  2. Compiling models into real-time systems

    International Nuclear Information System (INIS)

    Dormoy, J.L.; Cherriaux, F.; Ancelin, J.

    1992-08-01

    This paper presents an architecture for building real-time systems from models, and model-compiling techniques. This has been applied for building a real-time model-base monitoring system for nuclear plants, called KSE, which is currently being used in two plants in France. We describe how we used various artificial intelligence techniques for building it: a model-based approach, a logical model of its operation, a declarative implementation of these models, and original knowledge-compiling techniques for automatically generating the real-time expert system from those models. Some of those techniques have just been borrowed from the literature, but we had to modify or invent other techniques which simply did not exist. We also discuss two important problems, which are often underestimated in the artificial intelligence literature: size, and errors. Our architecture, which could be used in other applications, combines the advantages of the model-based approach with the efficiency requirements of real-time applications, while in general model-based approaches present serious drawbacks on this point

  3. Real Time Linux - The RTOS for Astronomy?

    Science.gov (United States)

    Daly, P. N.

    The BoF was attended by about 30 participants and a free CD of real time Linux-based upon RedHat 5.2-was available. There was a detailed presentation on the nature of real time Linux and the variants for hard real time: New Mexico Tech's RTL and DIAPM's RTAI. Comparison tables between standard Linux and real time Linux responses to time interval generation and interrupt response latency were presented (see elsewhere in these proceedings). The present recommendations are to use RTL for UP machines running the 2.0.x kernels and RTAI for SMP machines running the 2.2.x kernel. Support, both academically and commercially, is available. Some known limitations were presented and the solutions reported e.g., debugging and hardware support. The features of RTAI (scheduler, fifos, shared memory, semaphores, message queues and RPCs) were described. Typical performance statistics were presented: Pentium-based oneshot tasks running > 30kHz, 486-based oneshot tasks running at ~ 10 kHz, periodic timer tasks running in excess of 90 kHz with average zero jitter peaking to ~ 13 mus (UP) and ~ 30 mus (SMP). Some detail on kernel module programming, including coding examples, were presented showing a typical data acquisition system generating simulated (random) data writing to a shared memory buffer and a fifo buffer to communicate between real time Linux and user space. All coding examples were complete and tested under RTAI v0.6 and the 2.2.12 kernel. Finally, arguments were raised in support of real time Linux: it's open source, free under GPL, enables rapid prototyping, has good support and the ability to have a fully functioning workstation capable of co-existing hard real time performance. The counter weight-the negatives-of lack of platforms (x86 and PowerPC only at present), lack of board support, promiscuous root access and the danger of ignorance of real time programming issues were also discussed. See ftp://orion.tuc.noao.edu/pub/pnd/rtlbof.tgz for the StarOffice overheads

  4. The real-time price elasticity of electricity

    International Nuclear Information System (INIS)

    Lijesen, Mark G.

    2007-01-01

    The real-time price elasticity of electricity contains important information on the demand response of consumers to the volatility of peak prices. Despite the importance, empirical estimates of the real-time elasticity are hardly available. This paper provides a quantification of the real-time relationship between total peak demand and spot market prices. We find a low value for the real-time price elasticity, which may partly be explained from the fact that not all users observe the spot market price. If we correct for this phenomenon, we find the elasticity to be fairly low for consumers currently active in the spot market. If this conclusion applies to all users, this would imply a limited scope for government intervention in supply security issues. (Author)

  5. Sonography of the neonatal spine: part 1, Normal anatomy, imaging pitfalls, and variations that may simulate disorders.

    Science.gov (United States)

    Lowe, Lisa H; Johanek, Andrew J; Moore, Charlotte W

    2007-03-01

    Our objective is to discuss neonatal spine sonography with emphasis on imaging pitfalls and normal variants that may simulate disease and to distinguish them from true spinal disorders. Sonography of the neonatal spine is now accepted as a highly sensitive, readily available screening study that can be used to evaluate various anomalies of the lumbar spine in most infants younger than 4 months.

  6. A Programmable Microkernel for Real-Time Systems

    Science.gov (United States)

    2003-06-01

    A Programmable Microkernel for Real - Time Systems Christoph M. Kirsch Thomas A. Henzinger Marco A.A. Sanvido Report No. UCB/CSD-3-1250 June 2003...TITLE AND SUBTITLE A Programmable Microkernel for Real - Time Systems 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 A Programmable Microkernel for Real - Time Systems ∗ Christoph M

  7. The Significance of Brain Transcranial Sonography in Burning Mouth Syndrome: a Pilot Study

    Directory of Open Access Journals (Sweden)

    Iris Zavoreo

    2017-01-01

    Full Text Available Objective: Burning mouth syndrome (BMS is a chronic disorder which is affecting mostly postmenopausal women and is characterized by burning symptoms in the oral cavity on the clinically healthy oral mucosa. The results of previous studies suggested a possible role of peripheral and/or central neurological disturbances in these patients. The aim of this study was to analyze patients with burning mouth syndrome using transcranial sonography. Methods: By use of transcranial sonography of the brain parenchyma, substantia nigra, midbrain raphe and brain nucleus were evaluated in 20 patients with BMS (64.7±12.3 years and 20 controls with chronic pain in the lumbosacral region (61.5±15. Statistical analysis was performed by use of Student t test with significance set at p<0.05. Results: The results of this study have shown hypoechogenicity of the substantia nigra and midbrain raphe as well as hyperechogenicity of the brain nucleus in BMS patients (p<0,05 as compared to controls. Conclusions: Altered transcranial sonography findings of the brain parenchyma, midbrain raphe and brain nucleus in patients with burning mouth syndrome might reflect central disturbances within this syndrome.

  8. Real-time object-oriented programming: studies and proposals

    International Nuclear Information System (INIS)

    Fouquier, Gilles

    1996-01-01

    This thesis contributes to the introduction of real-time features in object-oriented programming. Object-oriented programming favours modularity and reusability. Therefore, its application to real-time introduces many theoretical and conceptual problems. To deal with these problems, a new real-time object-oriented programming model is presented. This model is based on the active object model which allows concurrence and maintains the encapsulation property. The real-time aspect is treated by replacing the concept of task by the concept of method processing and by associating a real-time constraint to each message (priority or deadline). The set of all the running methods is scheduled. This model, called ATOME, contains several sub-models to deal with the usual concurrence control integrating their priority and deadline processing. The classical HPF and EDF scheduling avoid priority or deadline inversion. This model and its variants are new proposals to program real-time applications in the object-oriented way, therefore easing reusability and code writing. The feasibility of this approach is demonstrated by extending and existing active object-based language to real-time, in using the rules defined in the ATOME model. (author) [fr

  9. Real-time simulation of large-scale floods

    Science.gov (United States)

    Liu, Q.; Qin, Y.; Li, G. D.; Liu, Z.; Cheng, D. J.; Zhao, Y. H.

    2016-08-01

    According to the complex real-time water situation, the real-time simulation of large-scale floods is very important for flood prevention practice. Model robustness and running efficiency are two critical factors in successful real-time flood simulation. This paper proposed a robust, two-dimensional, shallow water model based on the unstructured Godunov- type finite volume method. A robust wet/dry front method is used to enhance the numerical stability. An adaptive method is proposed to improve the running efficiency. The proposed model is used for large-scale flood simulation on real topography. Results compared to those of MIKE21 show the strong performance of the proposed model.

  10. Mechatronic modeling of real-time wheel-rail contact

    CERN Document Server

    Bosso, Nicola; Gugliotta, Antonio; Somà, Aurelio

    2013-01-01

    Real-time simulations of the behaviour of a rail vehicle require realistic solutions of the wheel-rail contact problem which can work in a real-time mode. Examples of such solutions for the online mode have been well known and are implemented within standard and commercial tools for the simulation codes for rail vehicle dynamics. This book is the result of the research activities carried out by the Railway Technology Lab of the Department of Mechanical and Aerospace Engineering at Politecnico di Torino. This book presents work on the project for the development of a real-time wheel-rail contact model and provides the simulation results obtained with dSpace real-time hardware. Besides this, the implementation of the contact model for the development of a real-time model for the complex mechatronic system of a scaled test rig is presented in this book and may be useful for the further validation of the real-time contact model with experiments on a full scale test rig.

  11. [Elastography as an additional tool in breast sonography. Technical principles and clinical applications].

    Science.gov (United States)

    Rjosk-Dendorfer, D; Reichelt, A; Clevert, D-A

    2014-03-01

    In recent years the use of elastography in addition to sonography has become a routine clinical tool for the characterization of breast masses. Whereas free hand compression elastography results in qualitative imaging of tissue stiffness due to induced compression, shear wave elastography displays quantitative information of tissue displacement. Recent studies have investigated the use of elastography in addition to sonography and improvement of specificity in differentiating benign from malignant breast masses could be shown. Therefore, additional use of elastography could help to reduce the number of unnecessary biopsies in benign breast lesions especially in category IV lesions of the ultrasound breast imaging reporting data system (US-BI-RADS).

  12. Internet-accessible real-time weather information system

    Digital Repository Service at National Institute of Oceanography (India)

    Desai, R.G.P.; Joseph, A.; Desa, E.; Mehra, P.; Desa, E.; Gouveia, A.D.

    An internet-accessible real-time weather information system has been developed. This system provides real-time accessibility to weather information from a multitude of spatially distributed weather stations. The Internet connectivity also offers...

  13. Automated real-time software development

    Science.gov (United States)

    Jones, Denise R.; Walker, Carrie K.; Turkovich, John J.

    1993-01-01

    A Computer-Aided Software Engineering (CASE) system has been developed at the Charles Stark Draper Laboratory (CSDL) under the direction of the NASA Langley Research Center. The CSDL CASE tool provides an automated method of generating source code and hard copy documentation from functional application engineering specifications. The goal is to significantly reduce the cost of developing and maintaining real-time scientific and engineering software while increasing system reliability. This paper describes CSDL CASE and discusses demonstrations that used the tool to automatically generate real-time application code.

  14. Geomagnetic Observatory Data for Real-Time Applications

    Science.gov (United States)

    Love, J. J.; Finn, C. A.; Rigler, E. J.; Kelbert, A.; Bedrosian, P.

    2015-12-01

    The global network of magnetic observatories represents a unique collective asset for the scientific community. Historically, magnetic observatories have supported global magnetic-field mapping projects and fundamental research of the Earth's interior and surrounding space environment. More recently, real-time data streams from magnetic observatories have become an important contributor to multi-sensor, operational monitoring of evolving space weather conditions, especially during magnetic storms. In this context, the U.S. Geological Survey (1) provides real-time observatory data to allied space weather monitoring projects, including those of NOAA, the U.S. Air Force, NASA, several international agencies, and private industry, (2) collaborates with Schlumberger to provide real-time geomagnetic data needed for directional drilling for oil and gas in Alaska, (3) develops products for real-time evaluation of hazards for the electric-power grid industry that are associated with the storm-time induction of geoelectric fields in the Earth's conducting lithosphere. In order to implement strategic priorities established by the USGS Natural Hazards Mission Area and the National Science and Technology Council, and with a focus on developing new real-time products, the USGS is (1) leveraging data management protocols already developed by the USGS Earthquake Program, (2) developing algorithms for mapping geomagnetic activity, a collaboration with NASA and NOAA, (3) supporting magnetotelluric surveys and developing Earth conductivity models, a collaboration with Oregon State University and the NSF's EarthScope Program, (4) studying the use of geomagnetic activity maps and Earth conductivity models for real-time estimation of geoelectric fields, (5) initiating geoelectric monitoring at several observatories, (6) validating real-time estimation algorithms against historical geomagnetic and geoelectric data. The success of these long-term projects is subject to funding constraints

  15. Real-time earthquake data feasible

    Science.gov (United States)

    Bush, Susan

    Scientists agree that early warning devices and monitoring of both Hurricane Hugo and the Mt. Pinatubo volcanic eruption saved thousands of lives. What would it take to develop this sort of early warning and monitoring system for earthquake activity?Not all that much, claims a panel assigned to study the feasibility, costs, and technology needed to establish a real-time earthquake monitoring (RTEM) system. The panel, drafted by the National Academy of Science's Committee on Seismology, has presented its findings in Real-Time Earthquake Monitoring. The recently released report states that “present technology is entirely capable of recording and processing data so as to provide real-time information, enabling people to mitigate somewhat the earthquake disaster.” RTEM systems would consist of two parts—an early warning system that would give a few seconds warning before severe shaking, and immediate postquake information within minutes of the quake that would give actual measurements of the magnitude. At this time, however, this type of warning system has not been addressed at the national level for the United States and is not included in the National Earthquake Hazard Reduction Program, according to the report.

  16. Verifying real-time systems against scenario-based requirements

    DEFF Research Database (Denmark)

    Larsen, Kim Guldstrand; Li, Shuhao; Nielsen, Brian

    2009-01-01

    We propose an approach to automatic verification of real-time systems against scenario-based requirements. A real-time system is modeled as a network of Timed Automata (TA), and a scenario-based requirement is specified as a Live Sequence Chart (LSC). We define a trace-based semantics for a kernel...... subset of the LSC language. By equivalently translating an LSC chart into an observer TA and then non-intrusively composing this observer with the original system model, the problem of verifying a real-time system against a scenario-based requirement reduces to a classical real-time model checking...

  17. Real-time UNIX in HEP data acquisition

    International Nuclear Information System (INIS)

    Buono, S.; Gaponenko, I.; Jones, R.; Mapelli, L.; Mornacchi, G.; Prigent, D.; Sanchez-Corral, E.; Skiadelli, M.; Toppers, A.; Duval, P.Y.; Ferrato, D.; Le Van Suu, A.; Qian, Z.; Rondot, C.; Ambrosini, G.; Fumagalli, G.; Aguer, M.; Huet, M.

    1994-01-01

    Today's experimentation in high energy physics is characterized by an increasing need for sensitivity to rare phenomena and complex physics signatures, which require the use of huge and sophisticated detectors and consequently a high performance readout and data acquisition. Multi-level triggering, hierarchical data collection and an always increasing amount of processing power, distributed throughout the data acquisition layers, will impose a number of features on the software environment, especially the need for a high level of standardization. Real-time UNIX seems, today, the best solution for the platform independence, operating system interface standards and real-time features necessary for data acquisition in HEP experiments. We present the results of the evaluation, in a realistic application environment, of a Real-Time UNIX operating system: the EP/LX real-time UNIX system. ((orig.))

  18. Clinical application of a modern high-definition head-mounted display in sonography.

    Science.gov (United States)

    Takeshita, Hideki; Kihara, Kazunori; Yoshida, Soichiro; Higuchi, Saori; Ito, Masaya; Nakanishi, Yasukazu; Kijima, Toshiki; Ishioka, Junichiro; Matsuoka, Yoh; Numao, Noboru; Saito, Kazutaka; Fujii, Yasuhisa

    2014-08-01

    Because of the remarkably improved image quality and wearability of modern head-mounted displays, a monitoring system using a head-mounted display rather than a fixed-site monitor for sonographic scanning has the potential to improve the diagnostic performance and lessen the examiner's physical burden during a sonographic examination. In a preclinical setting, 2 head-mounted displays, the HMZ-T2 (Sony Corporation, Tokyo, Japan) and the Wrap1200 (Vuzix Corporation, Rochester, NY), were found to be applicable to sonography. In a clinical setting, the feasibility of the HMZ-T2 was shown by its good image quality and acceptable wearability. This modern device is appropriate for clinical use in sonography. © 2014 by the American Institute of Ultrasound in Medicine.

  19. Temporal Specification and Verification of Real-Time Systems.

    Science.gov (United States)

    1991-08-30

    of concrete real - time systems can be modeled adequately. Specification: We present two conservative extensions of temporal logic that allow for the...logic. We present both model-checking algorithms for the automatic verification of finite-state real - time systems and proof methods for the deductive verification of real - time systems .

  20. ClockWork: a Real-Time Feasibility Analysis Tool

    NARCIS (Netherlands)

    Jansen, P.G.; Hanssen, F.T.Y.; Mullender, Sape J.

    ClockWork shows that we can improve the flexibility and efficiency of real-time kernels. We do this by proposing methods for scheduling based on so-called Real-Time Transactions. ClockWork uses Real-Time Transactions which allow scheduling decisions to be taken by the system. A programmer does not

  1. Fusion of hyperspectral remote sensing data for near real-time monitoring of microcystin distribution in Lake Erie

    Science.gov (United States)

    Vannah, Benjamin; Chang, Ni-Bin

    2013-09-01

    Urban growth and agricultural production have caused an influx of nutrients into Lake Erie, leading to eutrophic zones. These conditions result in the formation of algal blooms, some of which are toxic due to the presence of Microcystis (a cyanobacteria), which produces the hepatotoxin microcystin. Microcystis has a unique advantage over its competition as a result of the invasive zebra mussel population that filters algae out of the water column except for the toxic Microcystis. The toxin threatens human health and the ecosystem, and it is a concern for water treatment plants using the lake water as a tap water source. This presentation demonstrates the prototype of a near real-time early warning system using Integrated Data Fusion techniques with the aid of both hyperspectral remote sensing data to determine spatiotemporal microcystin concentrations. The temporal resolution of MODIS is fused with the higher spatial and spectral resolution of MERIS to create synthetic images on a daily basis. As a demonstration, the spatiotemporal distributions of microcystin within western Lake Erie are reconstructed using the band data from the fused products and applied machine-learning techniques. Analysis of the results through statistical indices confirmed that the this type of algorithm has better potential to accurately estimating microcystin concentrations in the lake, which is better than current two band models and other computational intelligence models.

  2. Failure analysis of real-time systems

    International Nuclear Information System (INIS)

    Jalashgar, A.; Stoelen, K.

    1998-01-01

    This paper highlights essential aspects of real-time software systems that are strongly related to the failures and their course of propagation. The significant influence of means-oriented and goal-oriented system views in the description, understanding and analysing of those aspects is elaborated. The importance of performing failure analysis prior to reliability analysis of real-time systems is equally addressed. Problems of software reliability growth models taking the properties of such systems into account are discussed. Finally, the paper presents a preliminary study of a goal-oriented approach to model the static and dynamic characteristics of real-time systems, so that the corresponding analysis can be based on a more descriptive and informative picture of failures, their effects and the possibility of their occurrence. (author)

  3. Can Real-Time Data Also Be Climate Quality?

    Science.gov (United States)

    Brewer, M.; Wentz, F. J.

    2015-12-01

    GMI, AMSR-2 and WindSat herald a new era of highly accurate and timely microwave data products. Traditionally, there has been a large divide between real-time and re-analysis data products. What if these completely separate processing systems could be merged? Through advanced modeling and physically based algorithms, Remote Sensing Systems (RSS) has narrowed the gap between real-time and research-quality. Satellite microwave ocean products have proven useful for a wide array of timely Earth science applications. Through cloud SST capabilities have enormously benefited tropical cyclone forecasting and day to day fisheries management, to name a few. Oceanic wind vectors enhance operational safety of shipping and recreational boating. Atmospheric rivers are of import to many human endeavors, as are cloud cover and knowledge of precipitation events. Some activities benefit from both climate and real-time operational data used in conjunction. RSS has been consistently improving microwave Earth Science Data Records (ESDRs) for several decades, while making near real-time data publicly available for semi-operational use. These data streams have often been produced in 2 stages: near real-time, followed by research quality final files. Over the years, we have seen this time delay shrink from months or weeks to mere hours. As well, we have seen the quality of near real-time data improve to the point where the distinction starts to blur. We continue to work towards better and faster RFI filtering, adaptive algorithms and improved real-time validation statistics for earlier detection of problems. Can it be possible to produce climate quality data in real-time, and what would the advantages be? We will try to answer these questions…

  4. FUSE: a profit maximization approach for functional summarization of biological networks

    Directory of Open Access Journals (Sweden)

    Seah Boon-Siew

    2012-03-01

    Full Text Available Abstract Background The availability of large-scale curated protein interaction datasets has given rise to the opportunity to investigate higher level organization and modularity within the protein interaction network (PPI using graph theoretic analysis. Despite the recent progress, systems level analysis of PPIS remains a daunting task as it is challenging to make sense out of the deluge of high-dimensional interaction data. Specifically, techniques that automatically abstract and summarize PPIS at multiple resolutions to provide high level views of its functional landscape are still lacking. We present a novel data-driven and generic algorithm called FUSE (Functional Summary Generator that generates functional maps of a PPI at different levels of organization, from broad process-process level interactions to in-depth complex-complex level interactions, through a pro t maximization approach that exploits Minimum Description Length (MDL principle to maximize information gain of the summary graph while satisfying the level of detail constraint. Results We evaluate the performance of FUSE on several real-world PPIS. We also compare FUSE to state-of-the-art graph clustering methods with GO term enrichment by constructing the biological process landscape of the PPIS. Using AD network as our case study, we further demonstrate the ability of FUSE to quickly summarize the network and identify many different processes and complexes that regulate it. Finally, we study the higher-order connectivity of the human PPI. Conclusion By simultaneously evaluating interaction and annotation data, FUSE abstracts higher-order interaction maps by reducing the details of the underlying PPI to form a functional summary graph of interconnected functional clusters. Our results demonstrate its effectiveness and superiority over state-of-the-art graph clustering methods with GO term enrichment.

  5. Academic Training: Real Time Process Control - Lecture series

    CERN Multimedia

    Françoise Benz

    2004-01-01

    ACADEMIC TRAINING LECTURE REGULAR PROGRAMME 7, 8 and 9 June From 11:00 hrs to 12:00 hrs - Main Auditorium bldg. 500 Real Time Process Control T. Riesco / CERN-TS What exactly is meant by Real-time? There are several definitions of real-time, most of them contradictory. Unfortunately the topic is controversial, and there does not seem to be 100% agreement over the terminology. Real-time applications are becoming increasingly important in our daily lives and can be found in diverse environments such as the automatic braking system on an automobile, a lottery ticket system, or robotic environmental samplers on a space station. These lectures will introduce concepts and theory like basic concepts timing constraints, task scheduling, periodic server mechanisms, hard and soft real-time.ENSEIGNEMENT ACADEMIQUE ACADEMIC TRAINING Françoise Benz 73127 academic.training@cern.ch

  6. The 2nd Generation Real Time Mission Monitor (RTMM) Development

    Science.gov (United States)

    Blakeslee, Richard; Goodman, Michael; Meyer, Paul; Hardin, Danny; Hall, John; He, Yubin; Regner, Kathryn; Conover, Helen; Smith, Tammy; Lu, Jessica; hide

    2009-01-01

    The NASA Real Time Mission Monitor (RTMM) is a visualization and information system that fuses multiple Earth science data sources, to enable real time decisionmaking for airborne and ground validation experiments. Developed at the National Aeronautics and Space Administration (NASA) Marshall Space Flight Center, RTMM is a situational awareness, decision-support system that integrates satellite imagery and orbit data, radar and other surface observations (e.g., lightning location network data), airborne navigation and instrument data sets, model output parameters, and other applicable Earth science data sets. The integration and delivery of this information is made possible using data acquisition systems, network communication links, network server resources, and visualizations through the Google Earth virtual globe application. In order to improve the usefulness and efficiency of the RTMM system, capabilities are being developed to allow the end-user to easily configure RTMM applications based on their mission-specific requirements and objectives. This second generation RTMM is being redesigned to take advantage of the Google plug-in capabilities to run multiple applications in a web browser rather than the original single application Google Earth approach. Currently RTMM employs a limited Service Oriented Architecture approach to enable discovery of mission specific resources. We are expanding the RTMM architecture such that it will more effectively utilize the Open Geospatial Consortium Sensor Web Enablement services and other new technology software tools and components. These modifications and extensions will result in a robust, versatile RTMM system that will greatly increase flexibility of the user to choose which science data sets and support applications to view and/or use. The improvements brought about by RTMM 2nd generation system will provide mission planners and airborne scientists with enhanced decision-making tools and capabilities to more

  7. Detection of Histoplasma capsulatum from clinical specimens by cycling probe-based real-time PCR and nested real-time PCR.

    Science.gov (United States)

    Muraosa, Yasunori; Toyotome, Takahito; Yahiro, Maki; Watanabe, Akira; Shikanai-Yasuda, Maria Aparecida; Kamei, Katsuhiko

    2016-05-01

    We developed new cycling probe-based real-time PCR and nested real-time PCR assays for the detection of Histoplasma capsulatum that were designed to detect the gene encoding N-acetylated α-linked acidic dipeptidase (NAALADase), which we previously identified as an H. capsulatum antigen reacting with sera from patients with histoplasmosis. Both assays specifically detected the DNAs of all H. capsulatum strains but not those of other fungi or human DNA. The limited of detection (LOD) of the real-time PCR assay was 10 DNA copies when using 10-fold serial dilutions of the standard plasmid DNA and 50 DNA copies when using human serum spiked with standard plasmid DNA. The nested real-time PCR improved the LOD to 5 DNA copies when using human serum spiked with standard plasmid DNA, which represents a 10-fold higher than that observed with the real-time PCR assay. To assess the ability of the two assays to diagnose histoplasmosis, we analyzed a small number of clinical specimens collected from five patients with histoplasmosis, such as sera (n = 4), formalin-fixed paraffin-embedded (FFPE) tissue (n = 4), and bronchoalveolar lavage fluid (BALF) (n = 1). Although clinical sensitivity of the real-time PCR assay was insufficiently sensitive (33%), the nested real-time PCR assay increased the clinical sensitivity (77%), suggesting it has a potential to be a useful method for detecting H. capsulatum DNA in clinical specimens. © The Author 2015. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Reviewing real-time performance of nuclear reactor safety systems

    International Nuclear Information System (INIS)

    Preckshot, G.G.

    1993-08-01

    The purpose of this paper is to recommend regulatory guidance for reviewers examining real-time performance of computer-based safety systems used in nuclear power plants. Three areas of guidance are covered in this report. The first area covers how to determine if, when, and what prototypes should be required of developers to make a convincing demonstration that specific problems have been solved or that performance goals have been met. The second area has recommendations for timing analyses that will prove that the real-time system will meet its safety-imposed deadlines. The third area has description of means for assessing expected or actual real-time performance before, during, and after development is completed. To ensure that the delivered real-time software product meets performance goals, the paper recommends certain types of code-execution and communications scheduling. Technical background is provided in the appendix on methods of timing analysis, scheduling real-time computations, prototyping, real-time software development approaches, modeling and measurement, and real-time operating systems

  9. Reviewing real-time performance of nuclear reactor safety systems

    Energy Technology Data Exchange (ETDEWEB)

    Preckshot, G.G. [Lawrence Livermore National Lab., CA (United States)

    1993-08-01

    The purpose of this paper is to recommend regulatory guidance for reviewers examining real-time performance of computer-based safety systems used in nuclear power plants. Three areas of guidance are covered in this report. The first area covers how to determine if, when, and what prototypes should be required of developers to make a convincing demonstration that specific problems have been solved or that performance goals have been met. The second area has recommendations for timing analyses that will prove that the real-time system will meet its safety-imposed deadlines. The third area has description of means for assessing expected or actual real-time performance before, during, and after development is completed. To ensure that the delivered real-time software product meets performance goals, the paper recommends certain types of code-execution and communications scheduling. Technical background is provided in the appendix on methods of timing analysis, scheduling real-time computations, prototyping, real-time software development approaches, modeling and measurement, and real-time operating systems.

  10. Collaborative Filtering Fusing Label Features Based on SDAE

    DEFF Research Database (Denmark)

    Huo, Huan; Liu, Xiufeng; Zheng, Deyuan

    2017-01-01

    problem, auxiliary information such as labels are utilized. Another approach of recommendation system is content-based model which can’t be directly integrated with CF-based model due to its inherent characteristics. Considering that deep learning algorithms are capable of extracting deep latent features......, this paper applies Stack Denoising Auto Encoder (SDAE) to content-based model and proposes LCF(Deep Learning for Collaborative Filtering) algorithm by combing CF-based model which fuses label features. Experiments on real-world data sets show that DLCF can largely overcome the sparsity problem...... and significantly improves the state of art approaches....

  11. Connecting real-time data to algorithms and databases: EarthCube's Cloud-Hosted Real-time Data Services for the Geosciences (CHORDS)

    Science.gov (United States)

    Daniels, M. D.; Graves, S. J.; Kerkez, B.; Chandrasekar, V.; Vernon, F.; Martin, C. L.; Maskey, M.; Keiser, K.; Dye, M. J.

    2015-12-01

    The Cloud-Hosted Real-time Data Services for the Geosciences (CHORDS) project was funded under the National Science Foundation's EarthCube initiative. CHORDS addresses the ever-increasing importance of real-time scientific data in the geosciences, particularly in mission critical scenarios, where informed decisions must be made rapidly. Access to constant streams of real-time data also allow many new transient phenomena in space-time to be observed, however, much of these streaming data are either completely inaccessible or only available to proprietary in-house tools or displays. Small research teams do not have the resources to develop tools for the broad dissemination of their unique real-time data and require an easy to use, scalable, cloud-based solution to facilitate this access. CHORDS will make these diverse streams of real-time data available to the broader geosciences community. This talk will highlight a recently developed CHORDS portal tools and processing systems which address some of the gaps in handling real-time data, particularly in the provisioning of data from the "long-tail" scientific community through a simple interface that is deployed in the cloud, is scalable and is able to be customized by research teams. A running portal, with operational data feeds from across the nation, will be presented. The processing within the CHORDS system will expose these real-time streams via standard services from the Open Geospatial Consortium (OGC) in a way that is simple and transparent to the data provider, while maximizing the usage of these investments. The ingestion of high velocity, high volume and diverse data has allowed the project to explore a NoSQL database implementation. Broad use of the CHORDS framework by geoscientists will help to facilitate adaptive experimentation, model assimilation and real-time hypothesis testing.

  12. Full spectrum endoscopy (FUSE) versus standard forward-viewing endoscope (SFV) in a high-risk population

    DEFF Research Database (Denmark)

    Roepstorff, Søren; Hadi, Sabah Anwar; Rasmussen, Morten

    2017-01-01

    OBJECTIVES: To investigate the diagnostic performance of Full Spectrum Endoscopy (FUSE) compared to a conventional standard forward-viewing endoscope (SFV). The primary outcome was adenoma detection rate (ADR) and mean adenoma detection. Secondary outcome was feasibility of FUSE opposed to SFV...... intubation time, fentanyl and midazolam sedation, CRC detection, ADR, diverticulosis, bowel preparation, patient discomfort and endoscopist difficulty rating. Participants underwent FUSE colonoscopy on days when the FUSE system was available, while the remaining participants had SFV. All colonoscopies were.......1 ± 6.2 min in the FUSE and SFV groups (p = .040). ADR was 67.0% and 59.6% (p = .097), while the mean adenoma detection was 1.79 and 1.38 (p = .022) in the FUSE and SFV groups. Endoscopists reported increased difficulty rating with FUSE compared to SFV (p > .001). CONCLUSION: FUSE colonoscopy provides...

  13. Virtual timers in hierarchical real-time systems

    NARCIS (Netherlands)

    Heuvel, van den M.M.H.P.; Holenderski, M.J.; Cools, W.A.; Bril, R.J.; Lukkien, J.J.; Zhu, D.

    2009-01-01

    Hierarchical scheduling frameworks (HSFs) provide means for composing complex real-time systems from welldefined subsystems. This paper describes an approach to provide hierarchically scheduled real-time applications with virtual event timers, motivated by the need for integrating priority

  14. Using modern teaching strategies to teach upper abdominal sonography to medical students

    Directory of Open Access Journals (Sweden)

    Wei-Chun Cheng

    2013-07-01

    Conclusion: We have greatly simplified the process of learning about upper abdominal sonography by using andragogy to enhance learning, mnemonics to help memory, and a pin-badge reward system to stimulate incentives.

  15. Real-time video compressing under DSP/BIOS

    Science.gov (United States)

    Chen, Qiu-ping; Li, Gui-ju

    2009-10-01

    This paper presents real-time MPEG-4 Simple Profile video compressing based on the DSP processor. The programming framework of video compressing is constructed using TMS320C6416 Microprocessor, TDS510 simulator and PC. It uses embedded real-time operating system DSP/BIOS and the API functions to build periodic function, tasks and interruptions etcs. Realize real-time video compressing. To the questions of data transferring among the system. Based on the architecture of the C64x DSP, utilized double buffer switched and EDMA data transfer controller to transit data from external memory to internal, and realize data transition and processing at the same time; the architecture level optimizations are used to improve software pipeline. The system used DSP/BIOS to realize multi-thread scheduling. The whole system realizes high speed transition of a great deal of data. Experimental results show the encoder can realize real-time encoding of 768*576, 25 frame/s video images.

  16. Real-time ISEE data system

    Science.gov (United States)

    Tsurutani, B. T.; Baker, D. N.

    1979-01-01

    A real-time ISEE data system directed toward predicting geomagnetic substorms and storms is discussed. Such a system may allow up to 60+ minutes advance warning of magnetospheric substorms and up to 30 minute warnings of geomagnetic storms (and other disturbances) induced by high-speed streams and solar flares. The proposed system utilizes existing capabilities of several agencies (NASA, NOAA, USAF), and thereby minimizes costs. This same concept may be applicable to data from other spacecraft, and other NASA centers; thus, each individual experimenter can receive quick-look data in real time at his or her base institution.

  17. An Indoor Scene Recognition-Based 3D Registration Mechanism for Real-Time AR-GIS Visualization in Mobile Applications

    Directory of Open Access Journals (Sweden)

    Wei Ma

    2018-03-01

    Full Text Available Mobile Augmented Reality (MAR systems are becoming ideal platforms for visualization, permitting users to better comprehend and interact with spatial information. Subsequently, this technological development, in turn, has prompted efforts to enhance mechanisms for registering virtual objects in real world contexts. Most existing AR 3D Registration techniques lack the scene recognition capabilities needed to describe accurately the positioning of virtual objects in scenes representing reality. Moreover, the application of such registration methods in indoor AR-GIS systems is further impeded by the limited capacity of these systems to detect the geometry and semantic information in indoor environments. In this paper, we propose a novel method for fusing virtual objects and indoor scenes, based on indoor scene recognition technology. To accomplish scene fusion in AR-GIS, we first detect key points in reference images. Then, we perform interior layout extraction using a Fully Connected Networks (FCN algorithm to acquire layout coordinate points for the tracking targets. We detect and recognize the target scene in a video frame image to track targets and estimate the camera pose. In this method, virtual 3D objects are fused precisely to a real scene, according to the camera pose and the previously extracted layout coordinate points. Our results demonstrate that this approach enables accurate fusion of virtual objects with representations of real world indoor environments. Based on this fusion technique, users can better grasp virtual three-dimensional representations on an AR-GIS platform.

  18. A distributed agent architecture for real-time knowledge-based systems: Real-time expert systems project, phase 1

    Science.gov (United States)

    Lee, S. Daniel

    1990-01-01

    We propose a distributed agent architecture (DAA) that can support a variety of paradigms based on both traditional real-time computing and artificial intelligence. DAA consists of distributed agents that are classified into two categories: reactive and cognitive. Reactive agents can be implemented directly in Ada to meet hard real-time requirements and be deployed on on-board embedded processors. A traditional real-time computing methodology under consideration is the rate monotonic theory that can guarantee schedulability based on analytical methods. AI techniques under consideration for reactive agents are approximate or anytime reasoning that can be implemented using Bayesian belief networks as in Guardian. Cognitive agents are traditional expert systems that can be implemented in ART-Ada to meet soft real-time requirements. During the initial design of cognitive agents, it is critical to consider the migration path that would allow initial deployment on ground-based workstations with eventual deployment on on-board processors. ART-Ada technology enables this migration while Lisp-based technologies make it difficult if not impossible. In addition to reactive and cognitive agents, a meta-level agent would be needed to coordinate multiple agents and to provide meta-level control.

  19. Duplex sonography in the planning and evaluation of arteriovenous fistulae for haemodialysis

    International Nuclear Information System (INIS)

    Kerr, S.F.; Krishan, S.; Lapham, R.C.; Weston, M.J.

    2010-01-01

    This paper describes how to perform duplex sonography in the planning and evaluation of arteriovenous fistulae in haemodialysis patients, discusses its roles in these settings, and presents a review of commonly encountered complications.

  20. Role of focused assessment with sonography for trauma as a ...

    African Journals Online (AJOL)

    Background: The objective of the study was to review the utility of focused assessement with sonography for trauma (FAST) as a screening tool for blunt abdominal trauma (BAT) in children involved in high energy trauma (HET), and to determine whether a FAST could replace computed tomography (CT) in clinical ...

  1. A Process For Performance Evaluation Of Real-Time Systems

    Directory of Open Access Journals (Sweden)

    Andrew J. Kornecki

    2003-12-01

    Full Text Available Real-time developers and engineers must not only meet the system functional requirements, but also the stringent timing requirements. One of the critical decisions leading to meeting these timing requirements is the selection of an operating system under which the software will be developed and run. Although there is ample documentation on real-time systems performance and evaluation, little can be found that combines such information into an efficient process for use by developers. As the software industry moves towards clearly defined processes, creation of appropriate guidelines describing a process for performance evaluation of real-time system would greatly benefit real-time developers. This technology transition research focuses on developing such a process. PROPERT (PROcess for Performance Evaluation of Real Time systems - the process described in this paper - is based upon established techniques for evaluating real-time systems. It organizes already existing real-time performance criteria and assessment techniques in a manner consistent with a well-formed process, based on the Personal Software Process concepts.

  2. Quantitative (real-time) PCR

    International Nuclear Information System (INIS)

    Denman, S.E.; McSweeney, C.S.

    2005-01-01

    Many nucleic acid-based probe and PCR assays have been developed for the detection tracking of specific microbes within the rumen ecosystem. Conventional PCR assays detect PCR products at the end stage of each PCR reaction, where exponential amplification is no longer being achieved. This approach can result in different end product (amplicon) quantities being generated. In contrast, using quantitative, or real-time PCR, quantification of the amplicon is performed not at the end of the reaction, but rather during exponential amplification, where theoretically each cycle will result in a doubling of product being created. For real-time PCR, the cycle at which fluorescence is deemed to be detectable above the background during the exponential phase is termed the cycle threshold (Ct). The Ct values obtained are then used for quantitation, which will be discussed later

  3. Real-time holographic endoscopy

    Science.gov (United States)

    Smigielski, Paul; Albe, Felix; Dischli, Bernard

    1992-08-01

    Some new experiments concerning holographic endoscopy are presented. The quantitative measurements of deformations of objects are obtained by the double-exposure and double- reference beam method, using either a cw-laser or a pulsed laser. Qualitative experiments using an argon laser with time-average holographic endoscopy are also presented. A video film on real-time endoscopic holographic interferometry was recorded with the help of a frequency-doubled YAG-laser working at 25 Hz for the first time.

  4. Comparative evaluation of fiber fuse models

    International Nuclear Information System (INIS)

    Davis, D.D.; Mettler, S.C.; DiGiovanni, D.J.

    1997-01-01

    A phenomenon which results in the catastrophic destruction of the guiding properties of an optical fiber has been observed at laser power densities on the order of 3 x 10 6 watts/cm 2 in the core. This phenomenon is characterized by the propagation of a bright visible light from the point of initiation toward the laser source. The term 'fiber fuse' has been used because of the similarity in appearance to a burning fuse. The fiber fuse has been shown to start when the end of the fiber is contacted. It has also been initiated spontaneously from mechanical splices. This paper reports experimental data gathered on the fiber fuse and discusses their relationship to proposed physical mechanisms

  5. Real-time computational photon-counting LiDAR

    Science.gov (United States)

    Edgar, Matthew; Johnson, Steven; Phillips, David; Padgett, Miles

    2018-03-01

    The availability of compact, low-cost, and high-speed MEMS-based spatial light modulators has generated widespread interest in alternative sampling strategies for imaging systems utilizing single-pixel detectors. The development of compressed sensing schemes for real-time computational imaging may have promising commercial applications for high-performance detectors, where the availability of focal plane arrays is expensive or otherwise limited. We discuss the research and development of a prototype light detection and ranging (LiDAR) system via direct time of flight, which utilizes a single high-sensitivity photon-counting detector and fast-timing electronics to recover millimeter accuracy three-dimensional images in real time. The development of low-cost real time computational LiDAR systems could have importance for applications in security, defense, and autonomous vehicles.

  6. Real time magnetic resonance guided endomyocardial local delivery

    Science.gov (United States)

    Corti, R; Badimon, J; Mizsei, G; Macaluso, F; Lee, M; Licato, P; Viles-Gonzalez, J F; Fuster, V; Sherman, W

    2005-01-01

    Objective: To investigate the feasibility of targeting various areas of left ventricle myocardium under real time magnetic resonance (MR) imaging with a customised injection catheter equipped with a miniaturised coil. Design: A needle injection catheter with a mounted resonant solenoid circuit (coil) at its tip was designed and constructed. A 1.5 T MR scanner with customised real time sequence combined with in-room scan running capabilities was used. With this system, various myocardial areas within the left ventricle were targeted and injected with a gadolinium-diethylenetriaminepentaacetic acid (DTPA) and Indian ink mixture. Results: Real time sequencing at 10 frames/s allowed clear visualisation of the moving catheter and its transit through the aorta into the ventricle, as well as targeting of all ventricle wall segments without further image enhancement techniques. All injections were visualised by real time MR imaging and verified by gross pathology. Conclusion: The tracking device allowed real time in vivo visualisation of catheters in the aorta and left ventricle as well as precise targeting of myocardial areas. The use of this real time catheter tracking may enable precise and adequate delivery of agents for tissue regeneration. PMID:15710717

  7. Interactive dual-volume rendering visualization with real-time fusion and transfer function enhancement

    Science.gov (United States)

    Macready, Hugh; Kim, Jinman; Feng, David; Cai, Weidong

    2006-03-01

    Dual-modality imaging scanners combining functional PET and anatomical CT constitute a challenge in volumetric visualization that can be limited by the high computational demand and expense. This study aims at providing physicians with multi-dimensional visualization tools, in order to navigate and manipulate the data running on a consumer PC. We have maximized the utilization of pixel-shader architecture of the low-cost graphic hardware and the texture-based volume rendering to provide visualization tools with high degree of interactivity. All the software was developed using OpenGL and Silicon Graphics Inc. Volumizer, tested on a Pentium mobile CPU on a PC notebook with 64M graphic memory. We render the individual modalities separately, and performing real-time per-voxel fusion. We designed a novel "alpha-spike" transfer function to interactively identify structure of interest from volume rendering of PET/CT. This works by assigning a non-linear opacity to the voxels, thus, allowing the physician to selectively eliminate or reveal information from the PET/CT volumes. As the PET and CT are rendered independently, manipulations can be applied to individual volumes, for instance, the application of transfer function to CT to reveal the lung boundary while adjusting the fusion ration between the CT and PET to enhance the contrast of a tumour region, with the resultant manipulated data sets fused together in real-time as the adjustments are made. In addition to conventional navigation and manipulation tools, such as scaling, LUT, volume slicing, and others, our strategy permits efficient visualization of PET/CT volume rendering which can potentially aid in interpretation and diagnosis.

  8. Prototyping Real-Time Control in the SPS

    CERN Document Server

    Andersson, J; Jensen, L; Jones, R; Lamont, M; Wenninger, J; Wijnands, Thijs; CERN. Geneva. AB Department

    2003-01-01

    Real-time control of beam related parameters will be required in the LHC. In order to gain experience of the issues involved in implementing distributed real-time control over large distances, a prototype local orbit feedback system is being developed in the SPS. This will use 6 pickups, each equipped with the full LHC acquisition electronics chain and linked to a real-time communication and feedback system. This reports summarises the .rst tests performed with this system in October 2002, where the data from four pickups was successfully acquired and displayed at 10 Hz in the control room.

  9. Formal methods for dependable real-time systems

    Science.gov (United States)

    Rushby, John

    1993-01-01

    The motivation for using formal methods to specify and reason about real time properties is outlined and approaches that were proposed and used are sketched. The formal verifications of clock synchronization algorithms are concluded as showing that mechanically supported reasoning about complex real time behavior is feasible. However, there was significant increase in the effectiveness of verification systems since those verifications were performed, at it is to be expected that verifications of comparable difficulty will become fairly routine. The current challenge lies in developing perspicuous and economical approaches to the formalization and specification of real time properties.

  10. Real time detecting system for turning force

    Energy Technology Data Exchange (ETDEWEB)

    Xiaobin, Yue [China Academy of Engineering Physics, Mianyang (China). Inst. of Machinery Manufacturing Technology

    2001-07-01

    How to get the real-time value of forces dropped on the tool in the course of processing by piezoelectric sensors is introduced. First, the analog signals of the cutting force were achieved by these sensors, amplified and transferred into digital signals by A/D transferring card. Then real-time software reads the information, put it into its own coordinate, drew the curve of forces, displayed it on the screen by the real time and saved it for the technicians to analyze the situation of the tool. So the cutting parameter can be optimized to improve surface quality of the pieces.

  11. Real Time Grid Reliability Management 2005

    Energy Technology Data Exchange (ETDEWEB)

    Eto, Joe; Eto, Joe; Lesieutre, Bernard; Lewis, Nancy Jo; Parashar, Manu

    2008-07-07

    The increased need to manage California?s electricity grid in real time is a result of the ongoing transition from a system operated by vertically-integrated utilities serving native loads to one operated by an independent system operator supporting competitive energy markets. During this transition period, the traditional approach to reliability management -- construction of new transmission lines -- has not been pursued due to unresolved issues related to the financing and recovery of transmission project costs. In the absence of investments in new transmission infrastructure, the best strategy for managing reliability is to equip system operators with better real-time information about actual operating margins so that they can better understand and manage the risk of operating closer to the edge. A companion strategy is to address known deficiencies in offline modeling tools that are needed to ground the use of improved real-time tools. This project: (1) developed and conducted first-ever demonstrations of two prototype real-time software tools for voltage security assessment and phasor monitoring; and (2) prepared a scoping study on improving load and generator response models. Additional funding through two separate subsequent work authorizations has already been provided to build upon the work initiated in this project.

  12. Real-time systems scheduling 2 focuses

    CERN Document Server

    Chetto, Maryline

    2014-01-01

    Real-time systems are used in a wide range of applications, including control, sensing, multimedia, etc. Scheduling is a central problem for these computing/communication systems since it is responsible for software execution in a timely manner. This book, the second of two volumes on the subject, brings together knowledge on specific topics and discusses the recent advances for some of them.  It addresses foundations as well as the latest advances and findings in real-time scheduling, giving comprehensive references to important papers, but the chapters are short and not overloaded with co

  13. Real-time Avatar Animation from a Single Image.

    Science.gov (United States)

    Saragih, Jason M; Lucey, Simon; Cohn, Jeffrey F

    2011-01-01

    A real time facial puppetry system is presented. Compared with existing systems, the proposed method requires no special hardware, runs in real time (23 frames-per-second), and requires only a single image of the avatar and user. The user's facial expression is captured through a real-time 3D non-rigid tracking system. Expression transfer is achieved by combining a generic expression model with synthetically generated examples that better capture person specific characteristics. Performance of the system is evaluated on avatars of real people as well as masks and cartoon characters.

  14. An Analysis of Input/Output Paradigms for Real-Time Systems

    Science.gov (United States)

    1990-07-01

    timing and concurrency aspects of real - time systems . This paper illustrates how to build a mathematical model of the schedulability of a real-time...various design alternatives. The primary characteristic that distinguishes real-time system from non- real - time systems is the importance of time. The

  15. A new systems engineering approach to streamlined science and mission operations for the Far Ultraviolet Spectroscopic Explorer (FUSE)

    Science.gov (United States)

    Butler, Madeline J.; Sonneborn, George; Perkins, Dorothy C.

    1994-01-01

    The Mission Operations and Data Systems Directorate (MO&DSD, Code 500), the Space Sciences Directorate (Code 600), and the Flight Projects Directorate (Code 400) have developed a new approach to combine the science and mission operations for the FUSE mission. FUSE, the last of the Delta-class Explorer missions, will obtain high resolution far ultraviolet spectra (910 - 1220 A) of stellar and extragalactic sources to study the evolution of galaxies and conditions in the early universe. FUSE will be launched in 2000 into a 24-hour highly eccentric orbit. Science operations will be conducted in real time for 16-18 hours per day, in a manner similar to the operations performed today for the International Ultraviolet Explorer. In a radical departure from previous missions, the operations concept combines spacecraft and science operations and data processing functions in a single facility to be housed in the Laboratory for Astronomy and Solar Physics (Code 680). A small missions operations team will provide the spacecraft control, telescope operations and data handling functions in a facility designated as the Science and Mission Operations Center (SMOC). This approach will utilize the Transportable Payload Operations Control Center (TPOCC) architecture for both spacecraft and instrument commanding. Other concepts of integrated operations being developed by the Code 500 Renaissance Project will also be employed for the FUSE SMOC. The primary objective of this approach is to reduce development and mission operations costs. The operations concept, integration of mission and science operations, and extensive use of existing hardware and software tools will decrease both development and operations costs extensively. This paper describes the FUSE operations concept, discusses the systems engineering approach used for its development, and the software, hardware and management tools that will make its implementation feasible.

  16. Spying on real-time computers to improve performance

    International Nuclear Information System (INIS)

    Taff, L.M.

    1975-01-01

    The sampled program-counter histogram, an established technique for shortening the execution times of programs, is described for a real-time computer. The use of a real-time clock allows particularly easy implementation. (Auth.)

  17. PERTS: A Prototyping Environment for Real-Time Systems

    Science.gov (United States)

    Liu, Jane W. S.; Lin, Kwei-Jay; Liu, C. L.

    1993-01-01

    PERTS is a prototyping environment for real-time systems. It is being built incrementally and will contain basic building blocks of operating systems for time-critical applications, tools, and performance models for the analysis, evaluation and measurement of real-time systems and a simulation/emulation environment. It is designed to support the use and evaluation of new design approaches, experimentations with alternative system building blocks, and the analysis and performance profiling of prototype real-time systems.

  18. Real-time multiple image manipulations

    International Nuclear Information System (INIS)

    Arenson, J.S.; Shalev, S.; Legris, J.; Goertzen, Y.

    1984-01-01

    There are many situations in which it is desired to manipulate two or more images under real-time operator control. The authors have investigated a number of such cases in order to determine their value and applicability in clinical medicine and laboratory research. Several examples are presented in detail. The DICOM-8 video image computer system was used due to its capability of storing two 512 x 512 x 8 bit images and operating on them, and/or an incoming video frame, with any of a number of real time operations including addition, subtraction, inversion, averaging, logical AND, NAND, OR, NOR, NOT, XOR and XNOR, as well as combinations of these. Some applications involve manipulations of or among the stored images. In others, a stored image is used as a mask or template for positioning or adjusting a second image to be grabbed via a video camera. The accuracy of radiotherapy treatment is verified by comparing port films with the original radiographic planning film, which is previously digitized and stored. Moving the port film on the light box while viewing the real-time subtraction image allows for adjustments of zoom, translation and rotation, together with contrast and edge enhancement

  19. Real-time position reconstruction with hippocampal place cells.

    Science.gov (United States)

    Guger, Christoph; Gener, Thomas; Pennartz, Cyriel M A; Brotons-Mas, Jorge R; Edlinger, Günter; Bermúdez I Badia, S; Verschure, Paul; Schaffelhofer, Stefan; Sanchez-Vives, Maria V

    2011-01-01

    Brain-computer interfaces (BCI) are using the electroencephalogram, the electrocorticogram and trains of action potentials as inputs to analyze brain activity for communication purposes and/or the control of external devices. Thus far it is not known whether a BCI system can be developed that utilizes the states of brain structures that are situated well below the cortical surface, such as the hippocampus. In order to address this question we used the activity of hippocampal place cells (PCs) to predict the position of an rodent in real-time. First, spike activity was recorded from the hippocampus during foraging and analyzed off-line to optimize the spike sorting and position reconstruction algorithm of rats. Then the spike activity was recorded and analyzed in real-time. The rat was running in a box of 80 cm × 80 cm and its locomotor movement was captured with a video tracking system. Data were acquired to calculate the rat's trajectories and to identify place fields. Then a Bayesian classifier was trained to predict the position of the rat given its neural activity. This information was used in subsequent trials to predict the rat's position in real-time. The real-time experiments were successfully performed and yielded an error between 12.2 and 17.4% using 5-6 neurons. It must be noted here that the encoding step was done with data recorded before the real-time experiment and comparable accuracies between off-line (mean error of 15.9% for three rats) and real-time experiments (mean error of 14.7%) were achieved. The experiment shows proof of principle that position reconstruction can be done in real-time, that PCs were stable and spike sorting was robust enough to generalize from the training run to the real-time reconstruction phase of the experiment. Real-time reconstruction may be used for a variety of purposes, including creating behavioral-neuronal feedback loops or for implementing neuroprosthetic control.

  20. Fused Bead Analysis of Diogenite Meteorites

    Science.gov (United States)

    Mittlefehldt, D.W.; Beck, B.W.; McSween, H.Y.; Lee, C.T. A.

    2009-01-01

    Bulk rock chemistry is an essential dataset in meteoritics and planetary science [1]. A common method used to obtain the bulk chemistry of meteorites is ICP-MS. While the accuracy, precision and low detection limits of this process are advantageous [2], the sample size used for analysis (approx.70 mg) can be a problem in a field where small and finite samples are the norm. Fused bead analysis is another bulk rock analytical technique that has been used in meteoritics [3]. This technique involves forming a glass bead from 10 mg of sample and measuring its chemistry using a defocused beam on a microprobe. Though the ICP-MS has lower detection limits than the microprobe, the fused bead method destroys a much smaller sample of the meteorite. Fused bead analysis was initially designed for samples with near-eutectic compositions and low viscosities. Melts generated of this type homogenize at relatively low temperatures and produce primary melts near the sample s bulk composition [3]. The application of fused bead analysis to samples with noneutectic melt compositions has not been validated. The purpose of this study is to test if fused bead analysis can accurately determine the bulk rock chemistry of non-eutectic melt composition meteorites. To determine this, we conduct two examinations of the fused bead. First, we compare ICP-MS and fused bead results of the same samples using statistical analysis. Secondly, we inspect the beads for the presence of crystals and chemical heterogeneity. The presence of either of these would indicate incomplete melting and quenching of the bead.

  1. The IPERMOB System for Effective Real-Time Road Travel Time Measurement and Prediction

    OpenAIRE

    Martelli, Francesca; Renda, Maria Elena; Santi, Paolo

    2010-01-01

    Accurate, real-time measurement and estimation of road travel time is considered a central problem in the design of advanced Intelligent Transportation Systems. In particular, whether eective, real-time collection of travel time measurements in a urban area is possible is, to the best of our knowledge, still an open problem. In this paper, we introduce the IPERMOB system for efficient, real-time collection of travel time measurements in urban areas through vehicular networks. We demonstrate t...

  2. Games and Scenarios for Real-Time System Validation

    DEFF Research Database (Denmark)

    Li, Shuhao

    This thesis presents research on the validation of real-time embedded software systems in the context of model-based development. The thesis proposes scenario-based and game-theoretic approaches to system analysis, verification, synthesis and testing to address the challenges that arise from....... By linking our prototype translators with existing model checker Uppaal and game solver Uppaal-Tiga, we show that these methods contribute to the interaction correctness and timeliness of early system designs. The thesis also shows that testing a real-time reactive system can be viewed as playing a timed...... communicating real-time systems can be modeled and specified with LSC. By translating LSC to timed automata (TAs), we reduce scenario-based model consistency checking and property verification to CTL real-time model checking problems, and reduce scenario-based synthesis to a timed game solving problem...

  3. Real time refractive index measurement by ESPI

    International Nuclear Information System (INIS)

    Torroba, R.; Joenathan, C.

    1991-01-01

    In this paper a method to measure refractive index variations in real time is reported. A technique to introduce reference fringes in real time is discussed. Both the theoretical and experimental results are presented and an example with phase shifting is given. (author). 8 refs, 5 figs

  4. The Synthesis of Intelligent Real-Time Systems

    Science.gov (United States)

    1990-11-09

    Synthesis of Intelligent Real - Time Systems . The purpose of the effort was to develop and extend theories and techniques that facilitate the design and...implementation of intelligent real - time systems . In particular, Teleos has extended situated-automata theory to apply to situations in which the system has

  5. Real-time software for the COMPASS tokamak plasma control

    International Nuclear Information System (INIS)

    Valcarcel, D.F.; Duarte, A.S.; Neto, A.; Carvalho, I.S.; Carvalho, B.B.; Fernandes, H.; Sousa, J.; Sartori, F.; Janky, F.; Cahyna, P.; Hron, M.; Panek, R.

    2010-01-01

    The COMPASS tokamak has started its operation recently in Prague and to meet the necessary operation parameters its real-time system, for data processing and control, must be designed for both flexibility and performance, allowing the easy integration of code from several developers and to guarantee the desired time cycle. For this purpose an Advanced Telecommunications Computing Architecture based real-time system has been deployed with a solution built on a multi-core x86 processor. It makes use of two software components: the BaseLib2 and the MARTe (Multithreaded Application Real-Time executor) real-time frameworks. The BaseLib2 framework is a generic real-time library with optimized objects for the implementation of real-time algorithms. This allowed to build a library of modules that process the acquired data and execute control algorithms. MARTe executes these modules in kernel space Real-Time Application Interface allowing to attain the required cycle time and a jitter of less than 1.5 μs. MARTe configuration and data storage are accomplished through a Java hardware client that connects to the FireSignal control and data acquisition software. This article details the implementation of the real-time system for the COMPASS tokamak, in particular the organization of the control code, the design and implementation of the communications with the actuators and how MARTe integrates with the FireSignal software.

  6. Real-time software for the COMPASS tokamak plasma control

    Energy Technology Data Exchange (ETDEWEB)

    Valcarcel, D.F., E-mail: danielv@ipfn.ist.utl.p [Associacao EURATOM/IST, Instituto de Plasmas e Fusao Nuclear - Laboratorio Associado, Instituto Superior Tecnico, P-1049-001 Lisboa (Portugal); Duarte, A.S.; Neto, A.; Carvalho, I.S.; Carvalho, B.B.; Fernandes, H.; Sousa, J. [Associacao EURATOM/IST, Instituto de Plasmas e Fusao Nuclear - Laboratorio Associado, Instituto Superior Tecnico, P-1049-001 Lisboa (Portugal); Sartori, F. [Euratom-UKAEA, Culham Science Centre, Abingdon, OX14 3DB Oxon (United Kingdom); Janky, F.; Cahyna, P.; Hron, M.; Panek, R. [Institute of Plasma Physics AS CR, v.v.i., Association EURATOM/IPP.CR, Za Slovankou 3, 182 00 Prague (Czech Republic)

    2010-07-15

    The COMPASS tokamak has started its operation recently in Prague and to meet the necessary operation parameters its real-time system, for data processing and control, must be designed for both flexibility and performance, allowing the easy integration of code from several developers and to guarantee the desired time cycle. For this purpose an Advanced Telecommunications Computing Architecture based real-time system has been deployed with a solution built on a multi-core x86 processor. It makes use of two software components: the BaseLib2 and the MARTe (Multithreaded Application Real-Time executor) real-time frameworks. The BaseLib2 framework is a generic real-time library with optimized objects for the implementation of real-time algorithms. This allowed to build a library of modules that process the acquired data and execute control algorithms. MARTe executes these modules in kernel space Real-Time Application Interface allowing to attain the required cycle time and a jitter of less than 1.5 {mu}s. MARTe configuration and data storage are accomplished through a Java hardware client that connects to the FireSignal control and data acquisition software. This article details the implementation of the real-time system for the COMPASS tokamak, in particular the organization of the control code, the design and implementation of the communications with the actuators and how MARTe integrates with the FireSignal software.

  7. Real-Time Optimization and Control of Next-Generation Distribution

    Science.gov (United States)

    -Generation Distribution Infrastructure Real-Time Optimization and Control of Next-Generation Distribution developing a system-theoretic distribution network management framework that unifies real-time voltage and Infrastructure | Grid Modernization | NREL Real-Time Optimization and Control of Next

  8. Real time psychrometric data collection

    International Nuclear Information System (INIS)

    McDaniel, K.H.

    1996-01-01

    Eight Mine Weather Stations (MWS) installed at the Waste Isolation Pilot Plant (WIPP) to monitor the underground ventilation system are helping to simulate real-time ventilation scenarios. Seasonal weather extremes can result in variations of Natural Ventilation Pressure (NVP) which can significantly effect the ventilation system. The eight MWS(s) (which previously collected and stored temperature, barometric pressure and relative humidity data for subsequent NVP calculations) were upgraded to provide continuous real-time data to the site wide Central monitoring System. This data can now be utilized by the ventilation engineer to create realtime ventilation simulations and trends which assist in the prediction and mitigation of NVP and psychrometric related events

  9. Sonography, CT and MR in soft part growths in the head and neck region

    International Nuclear Information System (INIS)

    Brinkmann, G.; Brix, F.; Beigel, A.

    1990-01-01

    14 patients with a space-occupying growth in the head and neck region were examined via sonography, CT and MR to explore and demonstrate by means of a prospective comparative study the possibilities offered by these three imaging methods. Stages are best diagnosed by means of sonography; the leading role of this method is undisputed. To clarify sonographically unclear findings and especially in pre-surgery planning, MR offers advantages over CT on account of the high soft-part contrast and multiplanar visualisation. However, it is impossible or very difficult to differentiate abscesses and lymphadenitides from malignant growths with these three methods solely on the basis of image-morphological criteria. (orig.) [de

  10. Real-time reactor coolant system pressure/temperature limit system

    International Nuclear Information System (INIS)

    Newton, D.G.; Schemmel, R.R.; Van Scooter, W.E. Jr.

    1991-01-01

    This patent describes an system, used in controlling the operating of a nuclear reactor coolant system, which automatically calculates and displays allowable reactor coolant system pressure/temperature limits within the nuclear reactor coolant system based upon real-time inputs. It comprises: means for producing signals representative of real-time operating parameters of the nuclear reactor cooling system; means for developing pressure and temperature limits relating the real-time operating parameters of the nuclear reactor coolant system, for normal and emergency operation thereof; means for processing the signals representative of real-time operating parameters of the nuclear reactor coolant system to perform calculations of a best estimate of signals, check manual inputs against permissible valves and test data acquisition hardware for validity and over/under range; and means for comparing the representative signals with limits for the real-time operating parameters to produce a signal for a real-time display of the pressure and temperature limits and of the real-time operating parameters use an operator in controlling the operation of the nuclear reactor coolant system

  11. Route around real time

    International Nuclear Information System (INIS)

    Terrier, Francois

    1996-01-01

    The greater and greater autonomy and complexity asked to the control and command systems lead to work on introducing techniques such as Artificial Intelligence or concurrent object programming in industrial applications. However, while the critical feature of these systems impose to control the dynamics of the proposed solutions, their complexity often imposes a high adaptability to a partially modelled environment. The studies presented start from low level control and command systems to more complex applications at higher levels, such as 'supervision systems'. Techniques such as temporal reasoning and uncertainty management are proposed for the first studies, while the second are tackled with programming techniques based on the real time object paradigm. The outcomes of this itinerary crystallize on the ACCORD project which targets to manage - on the whole life cycle of a real time application - these two problematics, sometimes antagonistic: control of the dynamics and adaptivity. (author) [fr

  12. Recent achievements in real-time computational seismology in Taiwan

    Science.gov (United States)

    Lee, S.; Liang, W.; Huang, B.

    2012-12-01

    Real-time computational seismology is currently possible to be achieved which needs highly connection between seismic database and high performance computing. We have developed a real-time moment tensor monitoring system (RMT) by using continuous BATS records and moment tensor inversion (CMT) technique. The real-time online earthquake simulation service is also ready to open for researchers and public earthquake science education (ROS). Combine RMT with ROS, the earthquake report based on computational seismology can provide within 5 minutes after an earthquake occurred (RMT obtains point source information ROS completes a 3D simulation real-time now. For more information, welcome to visit real-time computational seismology earthquake report webpage (RCS).

  13. Proceedings of the Real-Time Systems Engineering Workshop

    Science.gov (United States)

    2001-08-01

    real - time systems engineering. The workshop was held as part of the SEI Symposium in...Washington, DC, during September 2000. The objective of the workshop was to identify key issues and obtain feedback from attendees concerning real - time systems engineering...and interoperability. This report summarizes the workshop in terms of foundation, management, and technical topics, and it contains a discussion related to developing a community of interest for real - time systems

  14. Fusing Intelligence With Law Enforcement Information: An Analytic Imperative

    National Research Council Canada - National Science Library

    Thornlow, Christopher C

    2005-01-01

    ... and Law Enforcement Communities to fuse and analyze foreign threat intelligence with domestic law enforcement information in a timely fashion to provide adequate indications and warning of such an...

  15. Validation of RNAi by real time PCR

    DEFF Research Database (Denmark)

    Josefsen, Knud; Lee, Ying Chiu

    2011-01-01

    Real time PCR is the analytic tool of choice for quantification of gene expression, while RNAi is concerned with downregulation of gene expression. Together, they constitute a powerful approach in any loss of function studies of selective genes. We illustrate here the use of real time PCR to verify...

  16. Transcranial sonography and functional imaging in glucocerebrosidase mutation Parkinson disease.

    Science.gov (United States)

    Barrett, M J; Hagenah, J; Dhawan, V; Peng, S; Stanley, K; Raymond, D; Deik, A; Gross, S J; Schreiber-Agus, N; Mirelman, A; Marder, K; Ozelius, L J; Eidelberg, D; Bressman, S B; Saunders-Pullman, R

    2013-02-01

    Heterozygous glucocerebrosidase (GBA) mutations are the leading genetic risk factor for Parkinson disease, yet imaging correlates, particularly transcranial sonography, have not been extensively described. To determine whether GBA mutation heterozygotes with Parkinson disease demonstrate hyperechogenicity of the substantia nigra, transcranial sonography was performed in Ashkenazi Jewish Parkinson disease subjects, tested for the eight most common Gaucher disease mutations and the LRRK2 G2019S mutation, and in controls. [(18)F]-fluorodeoxyglucose or [(18)F]-fluorodopa positron emission tomography is also reported from a subset of Parkinson disease subjects with heterozygous GBA mutations. Parkinson disease subjects with heterozygous GBA mutations (n = 23) had a greater median maximal area of substantia nigral echogenicity compared to controls (n = 34, aSNmax = 0.30 vs. 0.18, p = 0.007). There was no difference in median maximal area of nigral echogenicity between Parkinson disease groups defined by GBA and LRRK2 genotype: GBA heterozygotes; GBA homozygotes/compound heterozygotes (n = 4, aSNmax = 0.27); subjects without LRRK2 or GBA mutations (n = 32, aSNmax = 0.27); LRRK2 heterozygotes/homozygotes without GBA mutations (n = 27, aSNmax = 0.28); and GBA heterozygotes/LRRK2 heterozygotes (n = 4, aSNmax = 0.32, overall p = 0.63). In secondary analyses among Parkinson disease subjects with GBA mutations, maximal area of nigral echogenicity did not differ based on GBA mutation severity or mutation number. [(18)F]-fluorodeoxyglucose (n = 3) and [(18)F]-fluorodopa (n = 2) positron emission tomography in Parkinson disease subjects with heterozygous GBA mutations was consistent with findings in idiopathic Parkinson disease. Both transcranial sonography and positron emission tomography are abnormal in GBA mutation associated Parkinson disease, similar to other Parkinson disease subjects. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. SignalR real time application development

    CERN Document Server

    Ingebrigtsen, Einar

    2013-01-01

    This step-by-step guide gives you practical advice, tips, and tricks that will have you writing real-time apps quickly and easily.If you are a .NET developer who wants to be at the cutting edge of development, then this book is for you. Real-time application development is made simple in this guide, so as long as you have basic knowledge of .NET, a copy of Visual Studio, and NuGet installed, you are ready to go.

  18. Real time monitoring of electron processors

    International Nuclear Information System (INIS)

    Nablo, S.V.; Kneeland, D.R.; McLaughlin, W.L.

    1995-01-01

    A real time radiation monitor (RTRM) has been developed for monitoring the dose rate (current density) of electron beam processors. The system provides continuous monitoring of processor output, electron beam uniformity, and an independent measure of operating voltage or electron energy. In view of the device's ability to replace labor-intensive dosimetry in verification of machine performance on a real-time basis, its application to providing archival performance data for in-line processing is discussed. (author)

  19. Limited Preemptive Scheduling in Real-time Systems

    OpenAIRE

    Thekkilakattil, Abhilash

    2016-01-01

    Preemptive and non-preemptive scheduling paradigms typically introduce undesirable side effects when scheduling real-time tasks, mainly in the form of preemption overheads and blocking, that potentially compromise timeliness guarantees. The high preemption overheads in preemptive real-time scheduling may imply high resource utilization, often requiring significant over-provisioning, e.g., pessimistic Worst Case Execution Time (WCET) approximations. Non-preemptive scheduling, on the other hand...

  20. Real time sensor for therapeutic radiation delivery

    International Nuclear Information System (INIS)

    Bliss, M.; Craig, R.A.; Reeder, P.L.

    1998-01-01

    The invention is a real time sensor for therapeutic radiation. A probe is placed in or near the patient that senses in real time the dose at the location of the probe. The strength of the dose is determined by either an insertion or an exit probe. The location is determined by a series of vertical and horizontal sensing elements that gives the operator a real time read out dose location relative to placement of the patient. The increased accuracy prevents serious tissue damage to the patient by preventing overdose or delivery of a dose to a wrong location within the body. 14 figs

  1. Coordinating Transit Transfers in Real Time

    Science.gov (United States)

    2016-05-06

    Transfers are a major source of travel time variability for transit passengers. Coordinating transfers between transit routes in real time can reduce passenger waiting times and travel time variability, but these benefits need to be contrasted with t...

  2. Timing organization of a real-time multicore processor

    DEFF Research Database (Denmark)

    Schoeberl, Martin; Sparsø, Jens

    2017-01-01

    Real-time systems need a time-predictable computing platform. Computation, communication, and access to shared resources needs to be time-predictable. We use time division multiplexing to statically schedule all computation and communication resources, such as access to main memory or message...... passing over a network-on-chip. We use time-driven communication over an asynchronous network-on-chip to enable time division multiplexing even in a globally asynchronous, locally synchronous multicore architecture. Using time division multiplexing at all levels of the architecture yields in a time...

  3. Tc-99m DTPA perfusion scintigraphy and color coded duplex sonography in the evaluation of minimal renal allograft perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Bair, H.J.; Platsch, G.; Wolf, F. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Nuclear Medicine; Guenter, E.; Becker, D. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Internal Medicine 1; Rupprecht, H.; Neumayer, H.H. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Internal Medicine 4

    1997-08-01

    Aim: The clinical impact of perfusion scintigraphy versus color coded Duplex sonography was evaluated, with respect to their potential in assessing minimal allograft perfusion in vitally threatened kidney transplants, i.e. oligoanuric allografts suspected to have either severe rejection or thrombosis of the renal vein or artery. Methods: From July 1990 to August 1994 the grafts of 15 out of a total of 315 patients were vitally threatened. Technetium-99m DTPA scintigraphy and color coded Duplex sonography were performed in all patients. For scintigraphic evaluation of transplant perfusion analog scans up to 60 min postinjection, and time-activity curves over the first 60 sec after injection of 370-440 MBq Tc-99m diethylenetriaminepentaacetate acid (DTPA) were used and classified by a perfusion score, the time between renal and iliac artery peaks (TDiff) and the washout of the renogram curve. Additionally, evaluation of excretion function and assessment of vascular or urinary leaks were performed. By color coded Duplex sonography the perfusion in all sections of the graft as well as the vascular anastomoses were examined and the maximal blood flow velocity (Vmax) and the resistive index (RI) in the renal artery were determined by means of the pulsed Doppler device. Pathologic-anatomical diagnosis was achieved by either biopsy or post-explant histology in all grafts. Results: Scintigraphy and color coded Duplex sonography could reliably differentiate minimal (8/15) and not perfused (7/15) renal allografts. The results were confirmed either by angiography in digital subtraction technique (DSA) or the clinical follow up. Conclusion: In summary, perfusion scintigraphy and color coded Duplex sonography are comparable modalities to assess kidney graft perfusion. In clinical practice scintigraphy and colorcoded Doppler sonography can replace digital subtraction angiography in the evaluation of minimal allograft perfusion. (orig.) [Deutsch] Ziel der Studie war es, das

  4. Real-time logo detection and tracking in video

    Science.gov (United States)

    George, M.; Kehtarnavaz, N.; Rahman, M.; Carlsohn, M.

    2010-05-01

    This paper presents a real-time implementation of a logo detection and tracking algorithm in video. The motivation of this work stems from applications on smart phones that require the detection of logos in real-time. For example, one application involves detecting company logos so that customers can easily get special offers in real-time. This algorithm uses a hybrid approach by initially running the Scale Invariant Feature Transform (SIFT) algorithm on the first frame in order to obtain the logo location and then by using an online calibration of color within the SIFT detected area in order to detect and track the logo in subsequent frames in a time efficient manner. The results obtained indicate that this hybrid approach allows robust logo detection and tracking to be achieved in real-time.

  5. A reliable information management for real-time systems

    International Nuclear Information System (INIS)

    Nishihara, Takuo; Tomita, Seiji

    1995-01-01

    In this paper, we propose a system configuration suitable for the hard realtime systems in which integrity and durability of information are important. On most hard real-time systems, where response time constraints are critical, the data which program access are volatile, and may be lost in case the systems are down. But for some real-time systems, the value-added intelligent network (IN) systems, e.g., integrity and durability of the stored data are very important. We propose a distributed system configuration for such hard real-time systems, comprised of service control modules and data management modules. The service control modules process transactions and responses based on deadline control, and the data management modules deal the stored data based on information recovery schemes well-restablished in fault real-time systems. (author)

  6. The Implementation of a Real-Time Polyphase Filter

    OpenAIRE

    Adámek, Karel; Novotný, Jan; Armour, Wes

    2014-01-01

    In this article we study the suitability of dierent computational accelerators for the task of real-time data processing. The algorithm used for comparison is the polyphase filter, a standard tool in signal processing and a well established algorithm. We measure performance in FLOPs and execution time, which is a critical factor for real-time systems. For our real-time studies we have chosen a data rate of 6.5GB/s, which is the estimated data rate for a single channel on the SKAs Low Frequenc...

  7. Improving Timeliness in Real-Time Secure Database Systems

    National Research Council Canada - National Science Library

    Son, Sang H; David, Rasikan; Thuraisingham, Bhavani

    2006-01-01

    .... In addition to real-time requirements, security is usually required in many applications. Multilevel security requirements introduce a new dimension to transaction processing in real-time database systems...

  8. Model-Checking Real-Time Control Programs

    DEFF Research Database (Denmark)

    Iversen, T. K.; Kristoffersen, K. J.; Larsen, Kim Guldstrand

    2000-01-01

    In this paper, we present a method for automatic verification of real-time control programs running on LEGO(R) RCX(TM) bricks using the verification tool UPPALL. The control programs, consisting of a number of tasks running concurrently, are automatically translated into the mixed automata model...... of UPPAAL. The fixed scheduling algorithm used by the LEGO(R) RCX(TM) processor is modeled in UPPALL, and supply of similar (sufficient) timed automata models for the environment allows analysis of the overall real-time system using the tools of UPPALL. To illustrate our technique for sorting LEGO(R) bricks...

  9. Cloud-Hosted Real-time Data Services for the Geosciences (CHORDS)

    Science.gov (United States)

    Daniels, M. D.; Graves, S. J.; Vernon, F.; Kerkez, B.; Chandra, C. V.; Keiser, K.; Martin, C.

    2014-12-01

    Cloud-Hosted Real-time Data Services for the Geosciences (CHORDS) Access, utilization and management of real-time data continue to be challenging for decision makers, as well as researchers in several scientific fields. This presentation will highlight infrastructure aimed at addressing some of the gaps in handling real-time data, particularly in increasing accessibility of these data to the scientific community through cloud services. The Cloud-Hosted Real-time Data Services for the Geosciences (CHORDS) system addresses the ever-increasing importance of real-time scientific data, particularly in mission critical scenarios, where informed decisions must be made rapidly. Advances in the distribution of real-time data are leading many new transient phenomena in space-time to be observed, however real-time decision-making is infeasible in many cases that require streaming scientific data as these data are locked down and sent only to proprietary in-house tools or displays. This lack of accessibility to the broader scientific community prohibits algorithm development and workflows initiated by these data streams. As part of NSF's EarthCube initiative, CHORDS proposes to make real-time data available to the academic community via cloud services. The CHORDS infrastructure will enhance the role of real-time data within the geosciences, specifically expanding the potential of streaming data sources in enabling adaptive experimentation and real-time hypothesis testing. Adherence to community data and metadata standards will promote the integration of CHORDS real-time data with existing standards-compliant analysis, visualization and modeling tools.

  10. Time-critical multirate scheduling using contemporary real-time operating system services

    Science.gov (United States)

    Eckhardt, D. E., Jr.

    1983-01-01

    Although real-time operating systems provide many of the task control services necessary to process time-critical applications (i.e., applications with fixed, invariant deadlines), it may still be necessary to provide a scheduling algorithm at a level above the operating system in order to coordinate a set of synchronized, time-critical tasks executing at different cyclic rates. The scheduling requirements for such applications and develops scheduling algorithms using services provided by contemporary real-time operating systems.

  11. Rectal sonography before and after radiation treatment in inoperable cervical cancer

    International Nuclear Information System (INIS)

    Deutinger, J.; Bernaschek, G.; Tatra, G.

    1989-01-01

    Transrectal sonography is helpful in the classification of parametrial infiltration prior to treatment as well as in the follow-up. In this study, we performed rectal sonography in cases of inoperable cervical cancer to objectify the reduction of the infiltration of the uterine cervix and of the parametrium. Rectosonography was performed in 10 patients with histologically confirmed cancer of the uterine cervix before and after radiation treatment. The patients were treated with brachytherapy and teletherapy with an average radiation dose of 7680 rad. The whole therapy was finished after 6 to 9 weeks. Rectosonography enabled us to objectify the effect of radiation therapy. The length and width of parametrial infiltration could be measured in relation to the pelvis wall. Furthermore, the configuration of the parametrium could be imaged. Therefore, in cervical cancer, rectosonography is a valuable method to check and the documentate the effect of treatment and to diagnose recurrency. (orig.) [de

  12. Diagnosis of brain death by transcranial Doppler sonography.

    Science.gov (United States)

    Bode, H; Sauer, M; Pringsheim, W

    1988-12-01

    The blood flow velocities in the basal cerebral arteries can be recorded at any age by transcranial Doppler sonography. We examined nine children with either initial or developing clinical signs of brain death. Soon after successful resuscitation increased diastolic flow velocities indicated a probable decrease in cerebrovascular resistance; this was of no particular prognostic importance. As soon as there was a clinical deterioration, there was a reduction in flow velocities with retrograde flow during early diastole, probably due to an increase in cerebrovascular resistance; this indicated a doubtful prognosis. In eight of the nine children with clinical signs of brain death a typical reverberating flow pattern was found, which was characterised by a counterbalancing short forward flow in systole and a short retrograde flow in early diastole. This indicated arrest of cerebral blood flow. One newborn showed normal systolic and end diastolic flow velocities in the basal cerebral arteries for two days despite clinical and electroencephalographic signs of brain death. Shunting of blood through the circle of Willis without effective cerebral perfusion may explain this phenomenon. No patient had the typical reverberating flow pattern without being clinically brain dead. Transcranial Doppler sonography is a reliable technique, which can be used at the bedside for the confirmation or the exclusion of brain death in children in addition to the clinical examination.

  13. Real-time ISEE data system

    International Nuclear Information System (INIS)

    Tsurutani, B.T.; Baker, D.N.

    1979-01-01

    Prediction of geomagnetic substorms and storms would be of great scientific and commercial interest. A real-time ISEE data system directed toward this purpose is discussed in detail. Such a system may allow up to 60+ minutes advance warning of magnetospheric substorms and up to 30 minute warnings of geomagnetic storms (and other disturbances) induced by high-speed streams and solar flares. The proposed system utilizes existing capabilities of several agencies (NASA, NOAA, USAF), and thereby minimizes costs. This same concept may be applicable to data from other spacecraft, and other NASA centers; thus, each individual experimenter can receive quick-look data in real time at his or her base institution. 6 figures, 1 table

  14. Automated Real-Time Clearance Analyzer (ARCA), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Automated Real-Time Clearance Analyzer (ARCA) addresses the future safety need for Real-Time System-Wide Safety Assurance (RSSA) in aviation and progressively...

  15. Deep Hashing Based Fusing Index Method for Large-Scale Image Retrieval

    Directory of Open Access Journals (Sweden)

    Lijuan Duan

    2017-01-01

    Full Text Available Hashing has been widely deployed to perform the Approximate Nearest Neighbor (ANN search for the large-scale image retrieval to solve the problem of storage and retrieval efficiency. Recently, deep hashing methods have been proposed to perform the simultaneous feature learning and the hash code learning with deep neural networks. Even though deep hashing has shown the better performance than traditional hashing methods with handcrafted features, the learned compact hash code from one deep hashing network may not provide the full representation of an image. In this paper, we propose a novel hashing indexing method, called the Deep Hashing based Fusing Index (DHFI, to generate a more compact hash code which has stronger expression ability and distinction capability. In our method, we train two different architecture’s deep hashing subnetworks and fuse the hash codes generated by the two subnetworks together to unify images. Experiments on two real datasets show that our method can outperform state-of-the-art image retrieval applications.

  16. Real-time interactive treatment planning

    International Nuclear Information System (INIS)

    Otto, Karl

    2014-01-01

    The goal of this work is to develop an interactive treatment planning platform that permits real-time manipulation of dose distributions including DVHs and other dose metrics. The hypothesis underlying the approach proposed here is that the process of evaluating potential dose distribution options and deciding on the best clinical trade-offs may be separated from the derivation of the actual delivery parameters used for the patient’s treatment. For this purpose a novel algorithm for deriving an Achievable Dose Estimate (ADE) was developed. The ADE algorithm is computationally efficient so as to update dose distributions in effectively real-time while accurately incorporating the limits of what can be achieved in practice. The resulting system is a software environment for interactive real-time manipulation of dose that permits the clinician to rapidly develop a fully customized 3D dose distribution. Graphical navigation of dose distributions is achieved by a sophisticated method of identifying contributing fluence elements, modifying those elements and re-computing the entire dose distribution. 3D dose distributions are calculated in ∼2–20 ms. Including graphics processing overhead, clinicians may visually interact with the dose distribution (e.g. ‘drag’ a DVH) and display updates of the dose distribution at a rate of more than 20 times per second. Preliminary testing on various sites shows that interactive planning may be completed in ∼1–5 min, depending on the complexity of the case (number of targets and OARs). Final DVHs are derived through a separate plan optimization step using a conventional VMAT planning system and were shown to be achievable within 2% and 4% in high and low dose regions respectively. With real-time interactive planning trade-offs between Target(s) and OARs may be evaluated efficiently providing a better understanding of the dosimetric options available to each patient in static or adaptive RT. (paper)

  17. Middle cerebral artery vasospasm: transcranial color-coded duplex sonography versus conventional nonimaging transcranial Doppler sonography.

    Science.gov (United States)

    Swiat, Maciej; Weigele, John; Hurst, Robert W; Kasner, Scott E; Pawlak, Mikolaj; Arkuszewski, Michal; Al-Okaili, Riyadh N; Swiercz, Miroslaw; Ustymowicz, Andrzej; Opala, Grzegorz; Melhem, Elias R; Krejza, Jaroslaw

    2009-03-01

    To prospectively compare accuracies of transcranial color-coded duplex sonography (TCCS) and transcranial Doppler sonography (TCD) in the diagnosis of middle cerebral artery (MCA) vasospasm. Prospective blinded head-to-head comparison TCD and TCCS methods using digital subtraction angiography (DSA) as the reference standard. Department of Radiology in a tertiary university health center in a metropolitan area. Eighty-one consecutive patients (mean age, 53.9 +/- 13.9 years; 48 women). The indication for DSA was subarachnoid hemorrhage in 71 patients (87.6%), stroke or transient ischemic attack in five patients (6.2%), and other reasons in five patients (6.2%). The MCA was graded as normal, narrowed 50% using DSA. The accuracy of ultrasound methods was estimated by total area (Az) under receiver operator characteristic curve. To compare sensitivities of ultrasound methods, McNemar's test was used with mean velocity thresholds of 120 cm/sec for the detection of less advanced, and 200 cm/sec for the more advanced MCA narrowing. Angiographic MCA narrowing 50% in 10 of 135 arteries. Accuracy of TCCS was insignificantly higher than that of TCD in the detection of 50% narrowing, total Az for mean velocity being 0.83 +/- 0.05, 0.77 +/- 0.05, and 0.95 +/- 0.02, 0.86 +/- 0.08, respectively. Sensitivity of TCCS at commonly used threshold of 120 cm/sec for less advanced MCA spasm was significantly better than that of TCD at similar specificity, 55% vs. 39%, p = 0.038, whereas at a threshold of 200 cm/sec used for more advanced spasm, sensitivities and specificities of both methods were not different. The accuracy of TCCS and TCD is similar, but TCCS is more sensitive than TCD in the detection of MCA spasm. Sensitivity of both techniques in the detection of mild and more advanced spasm using 120 cm/sec and 200 cm/sec thresholds, respectively, is poor; however, a larger sample is required to increase precision of our sensitivity estimates.

  18. Use of low fusing alloy in dentistry.

    Science.gov (United States)

    Wee, A G; Schneider, R L; Aquilino, S A

    1998-11-01

    Low fusing alloy has been used in dentistry for remount procedures in both fixed and removable prosthodontics, in implant prosthodontics for the fabrication of solid implant casts, in maxillofacial prosthetics as oral radiation shields, and in dental research for its unique properties. Previously, the use of low fusing alloy was thought to offer a high degree of dimensional accuracy. However, multiple in vitro studies have shown that its presumed dimensional accuracy may be questionable. This article reviews the physical properties, metallurgical considerations of low fusing alloy, its applications in dentistry, and a safe, simple method of using low fusing alloy.

  19. Real-time statistical quality control and ARM

    International Nuclear Information System (INIS)

    Blough, D.K.

    1992-05-01

    An important component of the Atmospheric Radiation Measurement (ARM) Program is real-time quality control of data obtained from meteorological instruments. It is the goal of the ARM program to enhance the predictive capabilities of global circulation models by incorporating in them more detailed information on the radiative characteristics of the earth's atmosphere. To this end, a number of Cloud and Radiation Testbeds (CART's) will be built at various locations worldwide. Each CART will consist of an array of instruments designed to collect radiative data. The large amount of data obtained from these instruments necessitates real-time processing in order to flag outliers and possible instrument malfunction. The Bayesian dynamic linear model (DLM) proves to be an effective way of monitoring the time series data which each instrument generates. It provides a flexible yet powerful approach to detecting in real-time sudden shifts in a non-stationary multivariate time series. An application of these techniques to data arising from a remote sensing instrument to be used in the CART is provided. Using real data from a wind profiler, the ability of the DLM to detect outliers is studied. 5 refs

  20. Explaining How to Play Real-Time Strategy Games

    Science.gov (United States)

    Metoyer, Ronald; Stumpf, Simone; Neumann, Christoph; Dodge, Jonathan; Cao, Jill; Schnabel, Aaron

    Real-time strategy games share many aspects with real situations in domains such as battle planning, air traffic control, and emergency response team management which makes them appealing test-beds for Artificial Intelligence (AI) and machine learning. End user annotations could help to provide supplemental information for learning algorithms, especially when training data is sparse. This paper presents a formative study to uncover how experienced users explain game play in real-time strategy games. We report the results of our analysis of explanations and discuss their characteristics that could support the design of systems for use by experienced real-time strategy game users in specifying or annotating strategy-oriented behavior.

  1. Correspondence between imaginary-time and real-time finite-temperature field theory

    International Nuclear Information System (INIS)

    Kobes, R.

    1990-01-01

    It is known that one-particle-irreducible graphs found using the imaginary-time formalism of finite-temperature field theory differ in general with those of the real-time formalism. Here it is shown that within the real-time formalism one can consider a sum of graphs, motivated by causality arguments, which at least in a number of simple examples agree with the corresponding analytically continued imaginary-time result. The occurrence of multiple statistical factors in this sum of graphs is discussed

  2. Refactoring Real-Time Java Profiles

    DEFF Research Database (Denmark)

    Søndergaard, Hans; Thomsen, Bent; Ravn, Anders Peter

    2011-01-01

    Just like other software, Java profiles benefits from refactoring when they have been used and have evolved for some time. This paper presents a refactoring of the Real-Time Specification for Java (RTSJ) and the Safety Critical Java (SCJ) profile (JSR-302). It highlights core concepts and makes...

  3. Criticality: static profiling for real-time programs

    DEFF Research Database (Denmark)

    Brandner, Florian; Hepp, Stefan; Jordan, Alexander

    2014-01-01

    With the increasing performance demand in real-time systems it becomes more and more important to provide feedback to programmers and software development tools on the performance-relevant code parts of a real-time program. So far, this information was limited to an estimation of the worst....... Experiments using well-established real-time benchmark programs show an interesting distribution of the criticality values, revealing considerable amounts of highly critical as well as uncritical code. The metric thus provides ideal information to programmers and software development tools to optimize...... view covering the entire code base, tools in the spirit of program profiling are required. This work proposes an efficient approach to compute worst-case timing information for all code parts of a program using a complementary metric, called criticality. Every statement of a program is assigned...

  4. Compilation and synthesis for real-time embedded controllers

    DEFF Research Database (Denmark)

    Fränzle, Martin; Müller-Olm, Markus

    1999-01-01

    This article provides an overview over two constructive approaches to provably correct hard real-time code generation where hard real-time code is generated from abstract requirements rather than verified against the timing requirements a posteriori. The first, more pragmatic approach is concerne......-time systems at a very high level of abstraction....

  5. Real-time advanced nuclear reactor core model

    International Nuclear Information System (INIS)

    Koclas, J.; Friedman, F.; Paquette, C.; Vivier, P.

    1990-01-01

    The paper describes a multi-nodal advanced nuclear reactor core model. The model is based on application of modern equivalence theory to the solution of neutron diffusion equation in real time employing the finite differences method. The use of equivalence theory allows the application of the finite differences method to cores divided into hundreds of nodes, as opposed to the much finer divisions (in the order of ten thousands of nodes) where the unmodified method is currently applied. As a result the model can be used for modelling of the core kinetics for real time full scope training simulators. Results of benchmarks, validate the basic assumptions of the model and its applicability to real-time simulation. (orig./HP)

  6. Clinical significance of neonatal parafrontal horn cysts detected by cranial sonography

    International Nuclear Information System (INIS)

    Woo, Jeong Joo; Jung, Myung Ja; Kim, Eun Ryung

    2005-01-01

    The describe the significance, incidence and characteristics of sonographic findings and long term outcomes of parafrontal horn cysts detected by screening cranial sonography done within the first week following birth. 2122 first cranial ultrasound scans performed over a five year period were retrospectively evaluated and 23 neonates with parafrontal horn cysts were found (which are different from secondary cystic lesions). 17 cases had a birth weight of 2400 gm with gestation between 34 and 41 weeks. The size, shape and location of the parafrontal horn cysts and other associated abnormalities shown on the cranial sonogram were evaluated and sequential ultrasound study, maternal records, neonatal events and neurodevelopmental evaluations were retrospectively assessed. Of the 23 subjects, 21 had isolated parafrontal horn cysts and 2 had subependymal hemorrhages. There was no record of any abnormal perinatal history. The cysts were bilateral in 20 neonates and unilateral in the others. The size of the cysts ranged from 3 to 18 mm in diameter (mean 9 mm). Sonographic features of the parafrontal horn cysts were distinctive morphology (elliptical, thin walled) and location (adjacent to the tip of the frontal horn). In 17 of the cases a follow-up cranial sonography was performed, and all parafrontal horn cysts disappeared within 3 to 6 months. Neurodevelopmental outcomes were normal in those 17 cases. Screening cranial sonography of neonates discovers isolated parafrontal horn cyst. The incidence of parafrontal horn cysts in neonates in our study was 1.1%. They are present in the first week following birth and resolve themselves without medical treatment within a few months. In addition, they show normal neurodevelopment. The parafrontal cysts are suspected to be a benign variant of normal neurodevelopment

  7. Hardware locks for a real-time Java chip multiprocessor

    DEFF Research Database (Denmark)

    Strøm, Torur Biskopstø; Puffitsch, Wolfgang; Schoeberl, Martin

    2016-01-01

    A software locking mechanism commonly protects shared resources for multithreaded applications. This mechanism can, especially in chip-multiprocessor systems, result in a large synchronization overhead. For real-time systems in particular, this overhead increases the worst-case execution time....... This improvement can allow a larger number of real-time tasks to be reliably scheduled on a multiprocessor real-time platform....

  8. Hard Real-Time Linux for Off-The-Shelf Multicore Architectures

    OpenAIRE

    Radder, Dirk

    2015-01-01

    This document describes the research results that were obtained from the development of a real-time extension for the Linux operating system. The paper describes a full extension of the kernel, which enables hard real-time performance on a 64-bit x86 architecture. In the first part of this study, real-time systems are categorized and concepts of real-time operating systems are introduced to the reader. In addition, numerous well-known real-time operating systems are considered. QNX Neutrino, ...

  9. Processor tradeoffs in distributed real-time systems

    Science.gov (United States)

    Krishna, C. M.; Shin, Kang G.; Bhandari, Inderpal S.

    1987-01-01

    The problem of the optimization of the design of real-time distributed systems is examined with reference to a class of computer architectures similar to the continuously reconfigurable multiprocessor flight control system structure, CM2FCS. Particular attention is given to the impact of processor replacement and the burn-in time on the probability of dynamic failure and mean cost. The solution is obtained numerically and interpreted in the context of real-time applications.

  10. A Radiographic Study of Fused and Geminated Tooth

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chul Jae; Lee, Sang Rae [Dept. of Oral Radiology, College of Dentistry, Kyunhee University, Seoul (Korea, Republic of)

    1990-02-15

    The incidence and several characteristic features of fused and geminated teeth were studied radiographically, with full mouth periapical radiogram and pantomogram, in 4201 patients of mixed dentition and 5358 patients of permanent dentition. The obtained results were as follows: 1. The prevalence was revealed to 2.86%, 0.32%, 0.33%, and 0.06% in deciduous fused tooth, permanent fused tooth, deciduous geminated tooth and permanent geminated tooth respectively, and these anomalies were occurred in female more than male. 2. Fused teeth were observed predominantly in lower anterior teeth area, especially in lateral incisor and canine region, and many cases of deciduous geminated tooth were observed in upper central incisor region. 3. Congenital missing rates of succedaneous tooth in deciduous fused teeth were 57.1%, 85.7%, 71.0%, 69.0% in upper right and left central-lateral incisor regions, lower right and left lateral incisor-canine regions, respectively. 4. Prevalence of dental caries was 42.3%, 18.8% and 5.6% in deciduous fused, deciduous geminated and permanent fused tooth, respectively. 5. In classifying of fused and geminated teeth into 9 type, by following appearance such as number of crown, root, pulp chamber and pulp canal of those teeth, it was more favorable that Type I (2 crown, 2 root, 2 pulp chamber, 2 pulp canal) in deciduous fused tooth and Type IX (1 crown, 1 root, 1 pulp chamber, 1 pulp canal) in permanent used tooth, deciduous and permanent geminated tooth.

  11. A Radiographic Study of Fused and Geminated Tooth

    International Nuclear Information System (INIS)

    Park, Chul Jae; Lee, Sang Rae

    1990-01-01

    The incidence and several characteristic features of fused and geminated teeth were studied radiographically, with full mouth periapical radiogram and pantomogram, in 4201 patients of mixed dentition and 5358 patients of permanent dentition. The obtained results were as follows: 1. The prevalence was revealed to 2.86%, 0.32%, 0.33%, and 0.06% in deciduous fused tooth, permanent fused tooth, deciduous geminated tooth and permanent geminated tooth respectively, and these anomalies were occurred in female more than male. 2. Fused teeth were observed predominantly in lower anterior teeth area, especially in lateral incisor and canine region, and many cases of deciduous geminated tooth were observed in upper central incisor region. 3. Congenital missing rates of succedaneous tooth in deciduous fused teeth were 57.1%, 85.7%, 71.0%, 69.0% in upper right and left central-lateral incisor regions, lower right and left lateral incisor-canine regions, respectively. 4. Prevalence of dental caries was 42.3%, 18.8% and 5.6% in deciduous fused, deciduous geminated and permanent fused tooth, respectively. 5. In classifying of fused and geminated teeth into 9 type, by following appearance such as number of crown, root, pulp chamber and pulp canal of those teeth, it was more favorable that Type I (2 crown, 2 root, 2 pulp chamber, 2 pulp canal) in deciduous fused tooth and Type IX (1 crown, 1 root, 1 pulp chamber, 1 pulp canal) in permanent used tooth, deciduous and permanent geminated tooth.

  12. Developments in architecture for real-time data systems

    International Nuclear Information System (INIS)

    Heath, R.L.; Myers, W.R.

    1975-01-01

    Real-time data systems typically operate at two levels: a fast-response instrument-oriented level for data acquisition and control, and a slow human-oriented level for interaction and computation. Traditional minicomputer data systems support real-time applications by implementation of background/foreground software. Recent developments in computer technology including microprocessors enable the functional organization of hardware in distributed or hierarchical form to provide new system structures for real-time requirements. Examples of systems with distributed architecture will be discussed in detail

  13. Additive manufacturing of transparent fused quartz

    Science.gov (United States)

    Luo, Junjie; Hostetler, John M.; Gilbert, Luke; Goldstein, Jonathan T.; Urbas, Augustine M.; Bristow, Douglas A.; Landers, Robert G.; Kinzel, Edward C.

    2018-04-01

    This paper investigates a filament-fed process for additive manufacturing (AM) of fused quartz. Glasses such as fused quartz have significant scientific and engineering applications, which include optics, communications, electronics, and hermetic seals. AM has several attractive benefits such as increased design freedom, faster prototyping, and lower processing costs for small production volumes. However, current research into glass AM has focused primarily on nonoptical applications. Fused quartz is studied here because of its desirability for use in high-quality optics due to its high transmissivity and thermal stability. Fused quartz filaments are fed into a CO2 laser-generated molten region, smoothly depositing material onto the workpiece. Spectroscopy and pyrometry are used to measure the thermal radiation incandescently emitted from the molten region. The effects of the laser power and scan speed are determined by measuring the morphology of single tracks. Thin walls are printed to study the effects of layer-to-layer height. This information is used to deposit solid pieces including a cylindrical-convex shape capable of focusing visible light. The transmittance and index homogeneity of the printed fused quartz are measured. These results show that the filament-fed process has the potential to print transmissive optics.

  14. Specification and Automated Verification of Real-Time Behaviour

    DEFF Research Database (Denmark)

    Kristensen, C.H.; Andersen, J.H.; Skou, A.

    1995-01-01

    In this paper we sketch a method for specification and automatic verification of real-time software properties.......In this paper we sketch a method for specification and automatic verification of real-time software properties....

  15. Specification and Automated Verification of Real-Time Behaviour

    DEFF Research Database (Denmark)

    Andersen, J.H.; Kristensen, C.H.; Skou, A.

    1996-01-01

    In this paper we sketch a method for specification and automatic verification of real-time software properties.......In this paper we sketch a method for specification and automatic verification of real-time software properties....

  16. Survey of real-time processing systems for big data

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Lftikhar, Nadeem; Xie, Xike

    2014-01-01

    In recent years, real-time processing and analytics systems for big data–in the context of Business Intelligence (BI)–have received a growing attention. The traditional BI platforms that perform regular updates on daily, weekly or monthly basis are no longer adequate to satisfy the fast......-changing business environments. However, due to the nature of big data, it has become a challenge to achieve the real-time capability using the traditional technologies. The recent distributed computing technology, MapReduce, provides off-the-shelf high scalability that can significantly shorten the processing time...... for big data; Its open-source implementation such as Hadoop has become the de-facto standard for processing big data, however, Hadoop has the limitation of supporting real-time updates. The improvements in Hadoop for the real-time capability, and the other alternative real-time frameworks have been...

  17. Timing system solution for MedAustron; Real-time event and data distribution network

    International Nuclear Information System (INIS)

    Stefanic, R.; Tavcar, R.; Dedic, J.; Gutleber, J.; Moser, R.

    2012-01-01

    MedAustron is an ion beam research and therapy centre under construction in Wiener Neustadt, Austria. The facility features a synchrotron particle accelerator for light ions. The timing system for this class of accelerators has been developed in close collaboration between MedAustron and Cosylab. Mitigating economical and technological risks, we have chosen a proven, widely used Micro Research Finland (MRF) timing equipment and redesigned its FPGA firmware, extending its high-logic services above transport layer, as required by machine specifics. We obtained a generic real-time broadcast network for coordinating actions of a compact, pulse-to-pulse modulation based particle accelerator. High-level services include support for virtual accelerators and a rich selection of event response mechanisms. The system uses a combination of a real-time link for downstream events and a non-real-time link for upstream messaging and non time-critical communication. It comes with National Instruments LabVIEW-based software support, ready to be integrated into PXIe based front-end controllers. This article explains the high level logic services provided by the real-time link, describes the non-real-time interfaces and presents the software configuration mechanisms. (authors)

  18. Soft-copy sonography: cost reduction sensitivity analysis in a pediatric hospital.

    Science.gov (United States)

    Don, S; Albertina, M J; Ammann, D

    1998-03-01

    Our objective was to determine whether interpreting sonograms of pediatric patients using soft-copy (computer workstation) instead of laser-printed film could reduce costs for a pediatric radiology department. We used theoretic models of growth to analyze costs. The costs of a sonographic picture archiving and communication system (three interface devices, two workstations, a network server, maintenance expenses, and storage media costs) were compared with the potential savings of eliminating film and increasing technologist efficiency or reducing the number of technologists. The model was based on historic trends and future capitation estimates that will reduce fee-for-service reimbursement. The effects of varying the study volume and reducing technologists' work hours were analyzed. By converting to soft-copy interpretation, we saved 6 min 32 sec per examination by eliminating film processing waiting time, thus reducing examination time from 30 min to 24 min. During an average day of 27 examinations, 176 min were saved. However, 33 min a day were spent retrieving prior studies from long-term storage; thus, 143 extra minutes a day were available for scanning. This improved efficiency could result in five more sonograms a day obtained by converting to soft-copy interpretation, using existing staff and equipment. Alternatively, five examinations a day would equate to one half of a full-time equivalent technologists position. Our analysis of costs considered that the hospital's anticipated growth of sonography and the depreciation of equipment during 5 years resulted in a savings of more than $606,000. Increasing the examinations by just 200 sonograms in the first year and no further growth resulted in a savings of more than $96,000. If the number of sonograms stayed constant, elimination of film printing alone resulted in a loss of approximately $157,000; reduction of one half of a full-time equivalent technologist's position would recuperate approximately $134

  19. Real-time variables dictionary (RTVD), and expert system for development of real-time applications in nuclear power plants

    International Nuclear Information System (INIS)

    Senra Martinez, A.; Schirru, R.; Dutra Thome Filho, Z.

    1990-01-01

    It is presented in this paper a computerized methodology based on a data dictionary managed by an expert system called Real-Time Variables Dictionary (RTVD). This system is very usefull for development of real-time applications in nuclear power plants. It is described in details the RTVD functions and its implantation in a VAX 8600 computer. It is also pointed out the concepts of artificial intelligence used in teh RTVD

  20. Locally advanced breast cancer: comparison of mammography, sonography and MR imaging in evaluation of residual disease in women receiving neoadjuvant chemotherapy

    International Nuclear Information System (INIS)

    Londero, Viviana; Bazzocchi, Massimo; Del Frate, Chiara; Francescutti, Giuliana; Zuiani, Chiara; Puglisi, Fabio; Di Loreto, Carla

    2004-01-01

    The accuracy of mammography, sonography and magnetic resonance imaging (MRI) in identifying residual disease after neoadjuvant chemotherapy is evaluated and imaging findings are correlated with pathologic findings. Fifteen patients enrolled in an experimental protocol of preoperative neoadjuvant chemotherapy underwent clinical examination, mammography, sonography and dynamic MRI, performed in this order, before and respectively after 2 and 4 cycles of neoadjuvant chemotherapy. Four radiologists, two for mammography, one for sonography and one for MR, examined the images, blinded to the results of the other examinations. All patients underwent radical or conservative surgery, and imaging findings were compared with pathologic findings. MRI identified 2/15 (13.3.%) clinically complete response (CR), 9/15 (60%) partial response (PR), 3/15 (20%) stable disease (SD) and 1/15 (6.7%) progressive disease. Mammography identified 1/15 (6.7%) clinically CR, 8/15 (53.3%) PR and 4/15 (27%) SD, and was not able to evaluate the disease in 2/15 (13%) cases. Sonography presented the same results as MRI. Therefore, MRI and sonography compared to mammography correctly identified residual disease in 100 vs. 86%. MRI resulted in two false-negative results because of the presence of microfoci of in situ ductal carcinoma (DCIS) and invasive lobular carcinoma (LCI). MRI was superior to mammography in cases of multifocal or multicentric disease (83 vs. 33%). Sonography performed after MRI improves the accuracy in evaluation of uncertain foci of multifocal disease seen on MR images with an increase of diagnostic accuracy from 73 to 84.5%. MRI assesses response to neoadjuvant chemotherapy better than traditional methods of physical examination and mammography. (orig.)

  1. Locally advanced breast cancer: comparison of mammography, sonography and MR imaging in evaluation of residual disease in women receiving neoadjuvant chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Londero, Viviana; Bazzocchi, Massimo; Del Frate, Chiara; Francescutti, Giuliana; Zuiani, Chiara [Institute of Radiology, University of Udine, via Colugna 50, 33100, Udine (Italy); Puglisi, Fabio [Department of Oncology, University of Udine, via Colugna 50, 33100, Udine (Italy); Di Loreto, Carla [Institute of Pathology, University of Udine, via Colugna 50, 33100, Udine (Italy)

    2004-08-01

    The accuracy of mammography, sonography and magnetic resonance imaging (MRI) in identifying residual disease after neoadjuvant chemotherapy is evaluated and imaging findings are correlated with pathologic findings. Fifteen patients enrolled in an experimental protocol of preoperative neoadjuvant chemotherapy underwent clinical examination, mammography, sonography and dynamic MRI, performed in this order, before and respectively after 2 and 4 cycles of neoadjuvant chemotherapy. Four radiologists, two for mammography, one for sonography and one for MR, examined the images, blinded to the results of the other examinations. All patients underwent radical or conservative surgery, and imaging findings were compared with pathologic findings. MRI identified 2/15 (13.3.%) clinically complete response (CR), 9/15 (60%) partial response (PR), 3/15 (20%) stable disease (SD) and 1/15 (6.7%) progressive disease. Mammography identified 1/15 (6.7%) clinically CR, 8/15 (53.3%) PR and 4/15 (27%) SD, and was not able to evaluate the disease in 2/15 (13%) cases. Sonography presented the same results as MRI. Therefore, MRI and sonography compared to mammography correctly identified residual disease in 100 vs. 86%. MRI resulted in two false-negative results because of the presence of microfoci of in situ ductal carcinoma (DCIS) and invasive lobular carcinoma (LCI). MRI was superior to mammography in cases of multifocal or multicentric disease (83 vs. 33%). Sonography performed after MRI improves the accuracy in evaluation of uncertain foci of multifocal disease seen on MR images with an increase of diagnostic accuracy from 73 to 84.5%. MRI assesses response to neoadjuvant chemotherapy better than traditional methods of physical examination and mammography. (orig.)

  2. Fused Adaptive Lasso for Spatial and Temporal Quantile Function Estimation

    KAUST Repository

    Sun, Ying; Wang, Huixia J.; Fuentes, Montserrat

    2015-01-01

    and temporal data with a fused adaptive Lasso penalty to accommodate the dependence in space and time. This method penalizes the difference among neighboring quantiles, hence it is desirable for applications with features ordered in time or space without

  3. Rt-Space: A Real-Time Stochastically-Provisioned Adaptive Container Environment

    Science.gov (United States)

    2017-08-04

    Real-Time Systems (ECRTS) Conference Location: Toulouse, France Paper Title: Multiprocessor Real-Time Locking Protocols for Replicated Resources...Conference Location: Lille, France Paper Title: A Contention-Sensitive Fine-Grained Locking Protocol for Multiprocessor Real-Time Systems Publication...On the Soft Real-Time Optimality of Global EDF on Multiprocessors: From Identical to Uniform Heterogeneous Publication Type: Conference Paper or

  4. Real-Time Engagement Area Development Program (READ-Pro)

    National Research Council Canada - National Science Library

    Burger, Joseph

    2002-01-01

    The Real Time Engagement Area Development Program (READ-Pro) is a PC-based prototype system which provides company-level commanders with real-time operational analysis tools to develop ENGAGEMENT AREAS(EA) for direct fire (DF) systems...

  5. Prenatal diagnosis of the Dandy-Walker syndrome by sonography and computed tomography

    International Nuclear Information System (INIS)

    Toelly, E.; Ebner, F.; Oberbauer, R.W.

    1984-01-01

    A case of Dandy-Walker-syndrome is presented, comparing the value of sonography and CT in intrauterine diagnosis. Together with a review of the literature of the subject, pathogenesis, morphology and prognosis in regard to the psychomotoric development are discussed. (orig.) [de

  6. MAC-Level Communication Time Modeling and Analysis for Real-Time WSNs

    Directory of Open Access Journals (Sweden)

    STANGACIU, V.

    2016-02-01

    Full Text Available Low-level communication protocols and their timing behavior are essential to developing wireless sensor networks (WSNs able to provide the support and operating guarantees required by many current real-time applications. Nevertheless, this aspect still remains an issue in the state-of-the-art. In this paper we provide a detailed analysis of a recently proposed MAC-level communication timing model and demonstrate its usability in designing real-time protocols. The results of a large set of measurements are also presented and discussed here, in direct relation to the main time parameters of the analyzed model.

  7. Real time ultrasonography in obstructive jaundice

    International Nuclear Information System (INIS)

    Cho, Kyung Sik; Kim, Ho Kyun; Sung, Nak Kwan; Kim, Soon Yong

    1982-01-01

    Ultrasonography is a predominantly accurate, relatively simple unique diagnostic method of obstructive jaundice. The ultrasonographic findings of obstructive jaundice are dilated intra- and extrahepatic duct with intraluminal hyper reflective echo or mass in and/ or around the bile duct. The superiority of high resolution real time ultrasonography for the diagnosis of obstructive jaundice is bases on the easy detectability of extra- and intrahepatic bile ducts by its multiple sectional images in a short time, the flexibility of probe and small crystal size. Author evaluated real time sonographic findings 46 obstructive jaundice patients confirmed by surgery or radiographical examinations. The results were: 1. Diameter of extrahepatic duct in obstructive jaundice were varied from normal to 4.0 Cm, mostly 8 to 10 mm in diameter (26%). Degree of dilatation of biliary duct appeared more prominent in cancer patients than other causes of obstruction. 2. The site of obstruction was detected in 85% (39/46) and its common site was common bile duct in 63% (29/46). 3. The diagnostic accuracy of choledocholithiasis and cancer was 82% (22/27) and 44% (4/9), respectively. Diagnostic accuracy of the real time ultrasonography in obstructive jaundice was over all 75% (34/46)

  8. Competitive On-Line Scheduling for Overloaded Real-Time Systems

    Science.gov (United States)

    1993-09-01

    Real - Time Systems by Gilad Koren a dissertation submitted in partial fulfillment of the requirements...Overloaded Real - Time Systems 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK...1.1 Introduction : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 2 1.1.1 Real - Time Systems : : : : : : : : : : : : : : : : : : : : : : : : : : : :

  9. Porphyrins Fused with Unactivated Polycyclic Aromatic Hydrocarbons

    KAUST Repository

    Diev, Vyacheslav V.; Schlenker, Cody W.; Hanson, Kenneth; Zhong, Qiwen; Zimmerman, Jeramy D.; Forrest, Stephen R.; Thompson, Mark E.

    2012-01-01

    A systematic study of the preparation of porphyrins with extended conjugation by meso,β-fusion with polycyclic aromatic hydrocarbons (PAHs) is reported. The meso-positions of 5,15-unsubstituted porphyrins were readily functionalized with PAHs. Ring fusion using standard Scholl reaction conditions (FeCl 3, dichloromethane) occurs for perylene-substituted porphyrins to give a porphyrin β,meso annulated with perylene rings (0.7:1 ratio of syn and anti isomers). The naphthalene, pyrene, and coronene derivatives do not react under Scholl conditions but are fused using thermal cyclodehydrogenation at high temperatures, giving mixtures of syn and anti isomers of the meso,β-fused porphyrins. For pyrenyl-substituted porphyrins, a thermal method gives synthetically acceptable yields (>30%). Absorption spectra of the fused porphyrins undergo a progressive bathochromic shift in a series of naphthyl (λ max = 730 nm), coronenyl (λ max = 780 nm), pyrenyl (λ max = 815 nm), and perylenyl (λ max = 900 nm) annulated porphyrins. Despite being conjugated with unsubstituted fused PAHs, the β,meso-fused porphyrins are more soluble and processable than the parent nonfused precursors. Pyrenyl-fused porphyrins exhibit strong fluorescence in the near-infrared (NIR) spectral region, with a progressive improvement in luminescent efficiency (up to 13% with λ max = 829 nm) with increasing degree of fusion. Fused pyrenyl-porphyrins have been used as broadband absorption donor materials in photovoltaic cells, leading to devices that show comparatively high photovoltaic efficiencies. © 2011 American Chemical Society.

  10. Porphyrins Fused with Unactivated Polycyclic Aromatic Hydrocarbons

    KAUST Repository

    Diev, Vyacheslav V.

    2012-01-06

    A systematic study of the preparation of porphyrins with extended conjugation by meso,β-fusion with polycyclic aromatic hydrocarbons (PAHs) is reported. The meso-positions of 5,15-unsubstituted porphyrins were readily functionalized with PAHs. Ring fusion using standard Scholl reaction conditions (FeCl 3, dichloromethane) occurs for perylene-substituted porphyrins to give a porphyrin β,meso annulated with perylene rings (0.7:1 ratio of syn and anti isomers). The naphthalene, pyrene, and coronene derivatives do not react under Scholl conditions but are fused using thermal cyclodehydrogenation at high temperatures, giving mixtures of syn and anti isomers of the meso,β-fused porphyrins. For pyrenyl-substituted porphyrins, a thermal method gives synthetically acceptable yields (>30%). Absorption spectra of the fused porphyrins undergo a progressive bathochromic shift in a series of naphthyl (λ max = 730 nm), coronenyl (λ max = 780 nm), pyrenyl (λ max = 815 nm), and perylenyl (λ max = 900 nm) annulated porphyrins. Despite being conjugated with unsubstituted fused PAHs, the β,meso-fused porphyrins are more soluble and processable than the parent nonfused precursors. Pyrenyl-fused porphyrins exhibit strong fluorescence in the near-infrared (NIR) spectral region, with a progressive improvement in luminescent efficiency (up to 13% with λ max = 829 nm) with increasing degree of fusion. Fused pyrenyl-porphyrins have been used as broadband absorption donor materials in photovoltaic cells, leading to devices that show comparatively high photovoltaic efficiencies. © 2011 American Chemical Society.

  11. Real-time operating system timing jitter and its impact on motor control

    Science.gov (United States)

    Proctor, Frederick M.; Shackleford, William P.

    2001-12-01

    General-purpose microprocessors are increasingly being used for control applications due to their widespread availability and software support for non-control functions like networking and operator interfaces. Two classes of real-time operating systems (RTOS) exist for these systems. The traditional RTOS serves as the sole operating system, and provides all OS services. Examples include ETS, LynxOS, QNX, Windows CE and VxWorks. RTOS extensions add real-time scheduling capabilities to non-real-time OSes, and provide minimal services needed for the time-critical portions of an application. Examples include RTAI and RTL for Linux, and HyperKernel, OnTime and RTX for Windows NT. Timing jitter is an issue in these systems, due to hardware effects such as bus locking, caches and pipelines, and software effects from mutual exclusion resource locks, non-preemtible critical sections, disabled interrupts, and multiple code paths in the scheduler. Jitter is typically on the order of a microsecond to a few tens of microseconds for hard real-time operating systems, and ranges from milliseconds to seconds in the worst case for soft real-time operating systems. The question of its significance on the performance of a controller arises. Naturally, the smaller the scheduling period required for a control task, the more significant is the impact of timing jitter. Aside from this intuitive relationship is the greater significance of timing on open-loop control, such as for stepper motors, than for closed-loop control, such as for servo motors. Techniques for measuring timing jitter are discussed, and comparisons between various platforms are presented. Techniques to reduce jitter or mitigate its effects are presented. The impact of jitter on stepper motor control is analyzed.

  12. Real-time subway information for improving transit ridership.

    Science.gov (United States)

    2016-08-01

    In recent years, the standardization of transit schedule information has yielded a dramatic increase in the accessibility of computerized transit schedules and given rise to real-time service schedules. Two such real-time service schedules are the Ge...

  13. Toxicity of inhaled 144Ce fused clay particles in beagle dogs. VII

    International Nuclear Information System (INIS)

    Hahn, F.F.; Boecker, B.B.; Hobbs, C.H.; Jones, R.K.; Mauderly, J.L.; McClellan, R.O.; Pickrell, J.A.

    1974-01-01

    The metabolism, dosimetry, and effects of inhaled 144 Ce in fused clay particles are being investigated in the Beagle dog to aid in assessing the biological consequences of release of 144 Ce in a relatively insoluble form such as might occur in certain types of nuclear accidents. The toxicity of inhaled 144 Ce fused clay is also of general interest since it is representative of intermediate-lived beta-emitting radionuclides. Two major studies with young adult dogs (12 to 14 months of age at exposure) are involved: (1) a metabolism and dosimetry study in which 24 dogs were serially sacrificed over an extended period of time, and (2) a longevity study with 2 series of dogs; Series I with 15 dogs exposed to aerosols of 144 Ce in fused clay particles to yield initial lung burdens of 11 to 210 μCi/kg body weight and 3 control dogs exposed to nonradioactive fused clay particles and Series II with 96 dogs exposed to aerosols of 144 Ce in fused clay particles to yield initial lung burdens of 0.0024 to 66 μCi/kg body weight and 12 control dogs exposed to nonradioactive fused clay particles. Twenty-eight dogs died or were euthanized at 143 to 2396 days after inhalation of 144 Ce. The prominent findings were radiation pneumonitis in 17 dogs that died or were euthanized at early time periods and neoplastic disease in 10 of the 11 dogs that died or were euthanized at 750 days or later; 5 with hemangiosarcoma of the lung, 1 with both a hemangiosarcoma and a fibrosarcoma of the lung, 1 with both a bronchiolo-alveolar carcinoma and a hemangiosarcoma of lung, 1 with a hemangiosarcoma of lung, bronchiolo-alveolar carcinoma, and a bronchiogenic adenocarcinoma, and 1 each with a hemangiosarcoma of the mediastinum and of the spleen. The cumulative radiation dose to the lung at time of death has ranged from 22,000 to 140,000 rads. Serial observations are continuing on the 83 survivors and 15 controls. (U.S.)

  14. Feedback as Real-Time Constructions

    Science.gov (United States)

    Keiding, Tina Bering; Qvortrup, Ane

    2014-01-01

    This article offers a re-description of feedback and the significance of time in feedback constructions based on systems theory. It describes feedback as internal, real-time constructions in a learning system. From this perspective, feedback is neither immediate nor delayed, but occurs in the very moment it takes place. This article argues for a…

  15. Building Real-Time Collaborative Applications with a Federated Architecture

    Directory of Open Access Journals (Sweden)

    Pablo Ojanguren-Menendez

    2015-12-01

    Full Text Available Real-time collaboration is being offered by multiple libraries and APIs (Google Drive Real-time API, Microsoft Real-Time Communications API, TogetherJS, ShareJS, rapidly becoming a mainstream option for webservices developers. However, they are offered as centralised services running in a single server, regardless if they are free/open source or proprietary software. After re-engineering Apache Wave (former Google Wave, we can now provide the first decentralised and federated free/open source alternative. The new API allows to develop new real-time collaborative web applications in both JavaScript and Java environments.

  16. "Internet of Things" Real-Time Free Flap Monitoring.

    Science.gov (United States)

    Kim, Sang Hun; Shin, Ho Seong; Lee, Sang Hwan

    2018-01-01

    Free flaps are a common treatment option for head and neck reconstruction in plastic reconstructive surgery, and monitoring of the free flap is the most important factor for flap survival. In this study, the authors performed real-time free flap monitoring based on an implanted Doppler system and "internet of things" (IoT)/wireless Wi-Fi, which is a convenient, accurate, and efficient approach for surgeons to monitor a free flap. Implanted Doppler signals were checked continuously until the patient was discharged by the surgeon and residents using their own cellular phone or personal computer. If the surgeon decided that a revision procedure or exploration was required, the authors checked the consumed time (positive signal-to-operating room time) from the first notification when the flap's status was questioned to the determination for revision surgery according to a chart review. To compare the efficacy of real-time monitoring, the authors paired the same number of free flaps performed by the same surgeon and monitored the flaps using conventional methods such as a physical examination. The total survival rate was greater in the real-time monitoring group (94.7% versus 89.5%). The average time for the real-time monitoring group was shorter than that for the conventional group (65 minutes versus 86 minutes). Based on this study, real-time free flap monitoring using IoT technology is a method that surgeon and reconstruction team can monitor simultaneously at any time in any situation.

  17. Real-time video streaming of sonographic clips using domestic internet networks and free videoconferencing software.

    Science.gov (United States)

    Liteplo, Andrew S; Noble, Vicki E; Attwood, Ben H C

    2011-11-01

    As the use of point-of-care sonography spreads, so too does the need for remote expert over-reading via telesonogrpahy. We sought to assess the feasibility of using familiar, widespread, and cost-effective existent technology to allow remote over-reading of sonograms in real time and to compare 4 different methods of transmission and communication for both the feasibility of transmission and image quality. Sonographic video clips were transmitted using 2 different connections (WiFi and 3G) and via 2 different videoconferencing modalities (iChat [Apple Inc, Cupertino, CA] and Skype [Skype Software Sàrl, Luxembourg]), for a total of 4 different permutations. The clips were received at a remote location and recorded and then scored by expert reviewers for image quality, resolution, and detail. Wireless transmission of sonographic clips was feasible in all cases when WiFi was used and when Skype was used over a 3G connection. Images transmitted via a WiFi connection were statistically superior to those transmitted via 3G in all parameters of quality (average P = .031), and those sent by iChat were superior to those sent by Skype but not statistically so (average P = .057). Wireless transmission of sonographic video clips using inexpensive hardware, free videoconferencing software, and domestic Internet networks is feasible with retention of image quality sufficient for interpretation. WiFi transmission results in greater image quality than transmission by a 3G network.

  18. Differentiation of widely invasive and minimally invasive follicular thyroid carcinoma with sonography

    International Nuclear Information System (INIS)

    Shin, Jung Hee; Han, Boo-Kyung; Ko, Eun Young; Oh, Young Lyun; Kim, Jung Han

    2010-01-01

    Purpose: We evaluated the sonographic findings that can help differentiate widely invasive follicular thyroid carcinomas (WIFTC) from minimally invasive follicular thyroid carcinomas (MIFTC). Methods: We retrospectively compared the sonographic and clinical findings of 24 patients (M:F = 5:19) with 24 MIFTCs and 12 patients (M:F = 1:11) with 13 WIFTCs that were confirmed pathologically and available in sonography at our institution between 1995 and 2007. Results: WIFTC was more common in elderly patients than MIFTC (p < 0.0001). WIFTC was seen with a larger size than MIFTC (p = 0.0092). The best cut-off values for age and size were 49 years and 5.6 cm, respectively. On sonography, all tumors were seen as a well-defined oval or round mass. Heterogeneous mulberry-like echotexture was more common for WIFTC than for MIFTC (77% vs. 25%) (p = 0.0046). The presence of calcifications was more frequent in WIFTC than in MIFTC (54% vs. 8%) (p = 0.0041). Ring calcifications (86%) were the most common type for WIFTC. WIFTC was commonly hypoechoic (70%) and rarely cystic change (8%), but without statistical differences. When WIFTCs represented tumors with two or more findings with a statistical difference, the specificity was 96%. Conclusion: WIFTC is distinguishable from MIFTC by sonography for patients with an age ≥49 years, a tumor ≥5.6 cm, a heterogeneous mulberry-like echotexure, or the presence of calcifications. The sonographic impression of a WIFTC can support a preoperative or intraoperative diagnosis of a difficult case as determined by FNA or with a frozen section.

  19. An integrated technique for developing real-time systems

    NARCIS (Netherlands)

    Hooman, J.J.M.; Vain, J.

    1995-01-01

    The integration of conceptual modeling techniques, formal specification, and compositional verification is considered for real time systems within the knowledge engineering context. We define constructive transformations from a conceptual meta model to a real time specification language and give

  20. SLStudio: Open-source framework for real-time structured light

    DEFF Research Database (Denmark)

    Wilm, Jakob; Olesen, Oline Vinter; Larsen, Rasmus

    2014-01-01

    that this software makes real-time 3D scene capture more widely accessible and serves as a foundation for new structured light scanners operating in real-time, e.g. 20 depth images per second and more. The use cases for such scanners are plentyfull, however due to the computational constraints, all public......An open-source framework for real-time structured light is presented. It is called “SLStudio”, and enables real-time capture of metric depth images. The framework is modular, and extensible to support new algorithms for scene encoding/decoding, triangulation, and aquisition hardware. It is the aim...... implementations so far are limited to offline processing. With “SLStudio”, we are making a platform available which enables researchers from many different fields to build application specific real time 3D scanners. The software is hosted at http://compute.dtu.dk/~jakw/slstudio....

  1. Real Time Processing

    CERN Multimedia

    CERN. Geneva; ANDERSON, Dustin James; DOGLIONI, Caterina

    2015-01-01

    The LHC provides experiments with an unprecedented amount of data. Experimental collaborations need to meet storage and computing requirements for the analysis of this data: this is often a limiting factor in the physics program that would be achievable if the whole dataset could be analysed. In this talk, I will describe the strategies adopted by the LHCb, CMS and ATLAS collaborations to overcome these limitations and make the most of LHC data: data parking, data scouting, and real-time analysis.

  2. Real-time safety risk assessment based on a real-time location system for hydropower construction sites.

    Science.gov (United States)

    Jiang, Hanchen; Lin, Peng; Fan, Qixiang; Qiang, Maoshan

    2014-01-01

    The concern for workers' safety in construction industry is reflected in many studies focusing on static safety risk identification and assessment. However, studies on real-time safety risk assessment aimed at reducing uncertainty and supporting quick response are rare. A method for real-time safety risk assessment (RTSRA) to implement a dynamic evaluation of worker safety states on construction site has been proposed in this paper. The method provides construction managers who are in charge of safety with more abundant information to reduce the uncertainty of the site. A quantitative calculation formula, integrating the influence of static and dynamic hazards and that of safety supervisors, is established to link the safety risk of workers with the locations of on-site assets. By employing the hidden Markov model (HMM), the RTSRA provides a mechanism for processing location data provided by the real-time location system (RTLS) and analyzing the probability distributions of different states in terms of false positives and negatives. Simulation analysis demonstrated the logic of the proposed method and how it works. Application case shows that the proposed RTSRA is both feasible and effective in managing construction project safety concerns.

  3. Real-time Energy Resource Scheduling considering a Real Portuguese Scenario

    DEFF Research Database (Denmark)

    Silva, Marco; Sousa, Tiago; Morais, Hugo

    2014-01-01

    The development in power systems and the introduction of decentralized gen eration and Electric Vehicles (EVs), both connected to distribution networks, represents a major challenge in the planning and operation issues. This new paradigm requires a new energy resources management approach which...... scheduling in smart grids, considering day - ahead, hour - ahead and real - time scheduling. The case study considers a 33 - bus distribution network with high penetration of distributed energy resources . The wind generation profile is base d o n a rea l Portuguese wind farm . Four scenarios are presented...... taking into account 0, 1, 2 and 5 periods (hours or minutes) ahead of the scheduling period in the hour - ahead and real - time scheduling...

  4. Real time gamma-ray signature identifier

    Science.gov (United States)

    Rowland, Mark [Alamo, CA; Gosnell, Tom B [Moraga, CA; Ham, Cheryl [Livermore, CA; Perkins, Dwight [Livermore, CA; Wong, James [Dublin, CA

    2012-05-15

    A real time gamma-ray signature/source identification method and system using principal components analysis (PCA) for transforming and substantially reducing one or more comprehensive spectral libraries of nuclear materials types and configurations into a corresponding concise representation/signature(s) representing and indexing each individual predetermined spectrum in principal component (PC) space, wherein an unknown gamma-ray signature may be compared against the representative signature to find a match or at least characterize the unknown signature from among all the entries in the library with a single regression or simple projection into the PC space, so as to substantially reduce processing time and computing resources and enable real-time characterization and/or identification.

  5. Real-Time Business Intelligence for the Utilities Industry

    Directory of Open Access Journals (Sweden)

    Janina POPEANGA

    2012-12-01

    Full Text Available In today’s competitive environment with rapid innovation in smart metering and smart grids, there is an increased need for real-time business intelligence (RTBI in the utilities industry. Giving the fact that this industry is an environment where decisions are time sensitive, RTBI solutions will help utilities improve customer experiences and operational efficiencies. The focus of this paper is on the importance of real-time business intelligence (RTBI in the utilities industry, outlining our vision of real-time business intelligence for this industry. Besides the analysis in this area, the article presents as a case study the Oracle Business Intelligence solution for utilities.

  6. Heterogeneous Data Fusion Method to Estimate Travel Time Distributions in Congested Road Networks.

    Science.gov (United States)

    Shi, Chaoyang; Chen, Bi Yu; Lam, William H K; Li, Qingquan

    2017-12-06

    Travel times in congested urban road networks are highly stochastic. Provision of travel time distribution information, including both mean and variance, can be very useful for travelers to make reliable path choice decisions to ensure higher probability of on-time arrival. To this end, a heterogeneous data fusion method is proposed to estimate travel time distributions by fusing heterogeneous data from point and interval detectors. In the proposed method, link travel time distributions are first estimated from point detector observations. The travel time distributions of links without point detectors are imputed based on their spatial correlations with links that have point detectors. The estimated link travel time distributions are then fused with path travel time distributions obtained from the interval detectors using Dempster-Shafer evidence theory. Based on fused path travel time distribution, an optimization technique is further introduced to update link travel time distributions and their spatial correlations. A case study was performed using real-world data from Hong Kong and showed that the proposed method obtained accurate and robust estimations of link and path travel time distributions in congested road networks.

  7. Real-time laser holographic interferometry for aerodynamics

    International Nuclear Information System (INIS)

    Lee, G.

    1987-01-01

    Recent developments in thermoplastic recording holograms and advancements in automated image digitalization and analysis make real-time laser holographic interferometry feasible for two-dimensional flows such as airfoil flows. Typical airfoil measurements would include airfoil pressure distributions, wake and boundary layer profiles, and flow field density contours. This paper addresses some of the problems and requirements of a real-time laser holographic interferometer. 13 references

  8. Coordinated scheduling for dynamic real-time systems

    Science.gov (United States)

    Natarajan, Swaminathan; Zhao, Wei

    1994-01-01

    In this project, we addressed issues in coordinated scheduling for dynamic real-time systems. In particular, we concentrated on design and implementation of a new distributed real-time system called R-Shell. The design objective of R-Shell is to provide computing support for space programs that have large, complex, fault-tolerant distributed real-time applications. In R-shell, the approach is based on the concept of scheduling agents, which reside in the application run-time environment, and are customized to provide just those resource management functions which are needed by the specific application. With this approach, we avoid the need for a sophisticated OS which provides a variety of generalized functionality, while still not burdening application programmers with heavy responsibility for resource management. In this report, we discuss the R-Shell approach, summarize the achievement of the project, and describe a preliminary prototype of R-Shell system.

  9. A real-time photogrammetry system based on embedded architecture

    Directory of Open Access Journals (Sweden)

    S. Y. Zheng

    2014-06-01

    Full Text Available In order to meet the demand of real-time spatial data processing and improve the online processing capability of photogrammetric system, a kind of real-time photogrammetry method is proposed in this paper. According to the proposed method, system based on embedded architecture is then designed: using FPGA, ARM+DSP and other embedded computing technology to build specialized hardware operating environment, transplanting and optimizing the existing photogrammetric algorithm to the embedded system, and finally real-time photogrammetric data processing is realized. At last, aerial photogrammetric experiment shows that the method can achieve high-speed and stable on-line processing of photogrammetric data. And the experiment also verifies the feasibility of the proposed real-time photogrammetric system based on embedded architecture. It is the first time to realize real-time aerial photogrammetric system, which can improve the online processing efficiency of photogrammetry to a higher level and broaden the application field of photogrammetry.

  10. Real-Time Tropospheric Delay Estimation using IGS Products

    Science.gov (United States)

    Stürze, Andrea; Liu, Sha; Söhne, Wolfgang

    2014-05-01

    The Federal Agency for Cartography and Geodesy (BKG) routinely provides zenith tropospheric delay (ZTD) parameter for the assimilation in numerical weather models since more than 10 years. Up to now the results flowing into the EUREF Permanent Network (EPN) or E-GVAP (EUMETNET EIG GNSS water vapour programme) analysis are based on batch processing of GPS+GLONASS observations in differential network mode. For the recently started COST Action ES1206 about "Advanced Global Navigation Satellite Systems tropospheric products for monitoring severe weather events and climate" (GNSS4SWEC), however, rapid updates in the analysis of the atmospheric state for nowcasting applications require changing the processing strategy towards real-time. In the RTCM SC104 (Radio Technical Commission for Maritime Services, Special Committee 104) a format combining the advantages of Precise Point Positioning (PPP) and Real-Time Kinematic (RTK) is under development. The so-called State Space Representation approach is defining corrections, which will be transferred in real-time to the user e.g. via NTRIP (Network Transport of RTCM via Internet Protocol). Meanwhile messages for precise orbits, satellite clocks and code biases compatible to the basic PPP mode using IGS products are defined. Consequently, the IGS Real-Time Service (RTS) was launched in 2013 in order to extend the well-known precise orbit and clock products by a real-time component. Further messages e.g. with respect to ionosphere or phase biases are foreseen. Depending on the level of refinement, so different accuracies up to the RTK level shall be reachable. In co-operation of BKG and the Technical University of Darmstadt the real-time software GEMon (GREF EUREF Monitoring) is under development. GEMon is able to process GPS and GLONASS observation and RTS product data streams in PPP mode. Furthermore, several state-of-the-art troposphere models, for example based on numerical weather prediction data, are implemented. Hence, it

  11. Reduced computational cost in the calculation of worst case response time for real time systems

    OpenAIRE

    Urriza, José M.; Schorb, Lucas; Orozco, Javier D.; Cayssials, Ricardo

    2009-01-01

    Modern Real Time Operating Systems require reducing computational costs even though the microprocessors become more powerful each day. It is usual that Real Time Operating Systems for embedded systems have advance features to administrate the resources of the applications that they support. In order to guarantee either the schedulability of the system or the schedulability of a new task in a dynamic Real Time System, it is necessary to know the Worst Case Response Time of the Real Time tasks ...

  12. Real-time measurement and control at Jet. Experiment Control

    International Nuclear Information System (INIS)

    Felton, R.; Zabeo, L.; Sartori, F.; Piccolo, F.; Farthing, J.; Budd, T.; Dorling, S.; McCullen, P.; Harling, J.; Dalley, S.; Goodyear, A.; Stephen, A.; Card, P.; Bright, M.; Lucock, R.; Jones, E.; Griph, S.; Hogben, C.; Beldishevski, M.; Buckley, M.; Davis, J.; Young, I.; Hemming, O.; Wheatley, M.; Heesterman, P.; Lloyd, G.; Walters, M.; Bridge, R.; Leggate, H.; Howell, D.; Zastrow, K.D.; Giroud, C.; Coffey, I.; Hawkes, N.; Stamp, M.; Barnsley, R.; Edlington, T.; Guenther, K.; Gowers, C.; Popovichef, S.; Huber, A.; Ingesson, C.; Joffrin, E.; Mazon, D.; Moreau, D.; Murari, A.; Riva, M.; Barana, O.; Bolzonella, T.; Valisa, M.; Innocente, P.; Zerbini, M.; Bosak, K.; Blum, J.; Vitale, E.; Crisanti, F.; La Luna, E. de; Sanchez, J.

    2004-01-01

    Over the past few ears, the preparation of ITER-relevant plasma scenarios has been the main focus experimental activity on tokamaks. The development of integrated, simultaneous, real-time controls of plasma shape, current, pressure, temperature, radiation, neutron profiles, and also impurities, ELMs (edge localized modes) and MHD are now seen to be essential for further development of quasi-steady state conditions with feedback, or the stabilisation of transient phenomena with event-driven actions. For this thrust, the EFDA JET Real Time Project has developed a set of real-time plasma measurements, experiment control, and communication facilities. The Plasma Diagnostics used for real-time experiments are Far Infra Red interferometry, polarimetry, visible, UV and X-ray spectroscopy, LIDAR, bolometry, neutron and magnetics. Further analysis systems produce integrated results such as temperature profiles on geometry derived from MHD equilibrium solutions. The Actuators include toroidal, poloidal and divertor coils, gas and pellet fuelling, neutral beam injection, radiofrequency (ICRH) waves and microwaves (LH). The Heating/Fuelling Operators can either define a power or gas request waveform or select the real-time instantaneous power/gas request from the Real Time Experiment Central Control (RTCC) system. The Real Time Experiment Control system provides both a high-level, control-programming environment and interlocks with the actuators. A MATLAB facility is being developed for the development of more complex controllers. The plasma measurement, controller and plant control systems communicate in ATM network. The EFDA Real Time project is essential groundwork for future reactors such as ITER. It involves many staff from several institutions. The facility is now frequently used in experiments. (authors)

  13. 30 CFR 57.12036 - Fuse removal or replacement.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fuse removal or replacement. 57.12036 Section 57.12036 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface and Underground § 57.12036 Fuse removal or replacement. Fuses shall not be removed or...

  14. Intelligent data management for real-time spacecraft monitoring

    Science.gov (United States)

    Schwuttke, Ursula M.; Gasser, Les; Abramson, Bruce

    1992-01-01

    Real-time AI systems have begun to address the challenge of restructuring problem solving to meet real-time constraints by making key trade-offs that pursue less than optimal strategies with minimal impact on system goals. Several approaches for adapting to dynamic changes in system operating conditions are known. However, simultaneously adapting system decision criteria in a principled way has been difficult. Towards this end, a general technique for dynamically making such trade-offs using a combination of decision theory and domain knowledge has been developed. Multi-attribute utility theory (MAUT), a decision theoretic approach for making one-time decisions is discussed and dynamic trade-off evaluation is described as a knowledge-based extension of MAUT that is suitable for highly dynamic real-time environments, and provides an example of dynamic trade-off evaluation applied to a specific data management trade-off in a real-world spacecraft monitoring application.

  15. Generating User Interfaces with the FUSE-System

    OpenAIRE

    Frank Lonczewski; Siegfried Schreiber

    2017-01-01

    With the FUSE(Formal User interface Specification Environment)-System we present a methodology and a set of integrated tools for the automatic generation of graphical user interfaces. FUSE provides tool-based support for all phases (task-, user-, problem domain analysis, design of the logical user interface, design of user interface in a particular layout style) of the user interface development process. Based on a formal specification of dialogue- and layout guidelines, FUSE allows the autom...

  16. Real-time earthquake monitoring: Early warning and rapid response

    Science.gov (United States)

    1991-01-01

    A panel was established to investigate the subject of real-time earthquake monitoring (RTEM) and suggest recommendations on the feasibility of using a real-time earthquake warning system to mitigate earthquake damage in regions of the United States. The findings of the investigation and the related recommendations are described in this report. A brief review of existing real-time seismic systems is presented with particular emphasis given to the current California seismic networks. Specific applications of a real-time monitoring system are discussed along with issues related to system deployment and technical feasibility. In addition, several non-technical considerations are addressed including cost-benefit analysis, public perceptions, safety, and liability.

  17. True Time API Link (real time arrival info)

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — This link will take you to the site where you can create an account to access Port Authority's real time arrival information. To request access to Port Authority's...

  18. Experiments with the Sun Java Real-Time System -- Part 2

    National Research Council Canada - National Science Library

    Auguston, Mikhail; Cook, Thomas S; Drusinsky, Doron; Michael, James B; Otani, Thomas W; Shing, Man-Tak

    2007-01-01

    In the authors' first report on the Sun Java Real-Time System (RTS), they concluded that it is preferable to use real-time Java threads that use heap memory rather than no-heap real-time threads (NHRTTs...

  19. Clinical significance of neonatal parafrontal horn cysts detected by cranial sonography

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Jeong Joo [Eulji University of Medicine, Daejeon (Korea, Republic of); Jung, Myung Ja [Sanggye Paik Hospital, Inje University of Medicine, Seoul (Korea, Republic of); Kim, Eun Ryung [Sungae General Hospital, Seoul (Korea, Republic of)

    2005-07-15

    The describe the significance, incidence and characteristics of sonographic findings and long term outcomes of parafrontal horn cysts detected by screening cranial sonography done within the first week following birth. 2122 first cranial ultrasound scans performed over a five year period were retrospectively evaluated and 23 neonates with parafrontal horn cysts were found (which are different from secondary cystic lesions). 17 cases had a birth weight of < 2400 gm with gestation between 30 and 35 weeks, 6 cases had a birth weight of > 2400 gm with gestation between 34 and 41 weeks. The size, shape and location of the parafrontal horn cysts and other associated abnormalities shown on the cranial sonogram were evaluated and sequential ultrasound study, maternal records, neonatal events and neurodevelopmental evaluations were retrospectively assessed. Of the 23 subjects, 21 had isolated parafrontal horn cysts and 2 had subependymal hemorrhages. There was no record of any abnormal perinatal history. The cysts were bilateral in 20 neonates and unilateral in the others. The size of the cysts ranged from 3 to 18 mm in diameter (mean 9 mm). Sonographic features of the parafrontal horn cysts were distinctive morphology (elliptical, thin walled) and location (adjacent to the tip of the frontal horn). In 17 of the cases a follow-up cranial sonography was performed, and all parafrontal horn cysts disappeared within 3 to 6 months. Neurodevelopmental outcomes were normal in those 17 cases. Screening cranial sonography of neonates discovers isolated parafrontal horn cyst. The incidence of parafrontal horn cysts in neonates in our study was 1.1%. They are present in the first week following birth and resolve themselves without medical treatment within a few months. In addition, they show normal neurodevelopment. The parafrontal cysts are suspected to be a benign variant of normal neurodevelopment.

  20. An approach to a real-time distribution system

    Science.gov (United States)

    Kittle, Frank P., Jr.; Paddock, Eddie J.; Pocklington, Tony; Wang, Lui

    1990-01-01

    The requirements of a real-time data distribution system are to provide fast, reliable delivery of data from source to destination with little or no impact to the data source. In this particular case, the data sources are inside an operational environment, the Mission Control Center (MCC), and any workstation receiving data directly from the operational computer must conform to the software standards of the MCC. In order to supply data to development workstations outside of the MCC, it is necessary to use gateway computers that prevent unauthorized data transfer back to the operational computers. Many software programs produced on the development workstations are targeted for real-time operation. Therefore, these programs must migrate from the development workstation to the operational workstation. It is yet another requirement for the Data Distribution System to ensure smooth transition of the data interfaces for the application developers. A standard data interface model has already been set up for the operational environment, so the interface between the distribution system and the application software was developed to match that model as closely as possible. The system as a whole therefore allows the rapid development of real-time applications without impacting the data sources. In summary, this approach to a real-time data distribution system provides development users outside of the MCC with an interface to MCC real-time data sources. In addition, the data interface was developed with a flexible and portable software design. This design allows for the smooth transition of new real-time applications to the MCC operational environment.

  1. Investigation of fused silica dynamic behaviour

    International Nuclear Information System (INIS)

    Malaise, F.; Chevalier, J.M.; Bertron, I.; Malka, F.

    2006-01-01

    The survivability of the fused silica shields to shrapnel impacts is a key factor for the affordable operation of the intense laser irradiation future facility Laser Mega Joule (LMJ). This paper presents experimental data and computational modelling for LMJ fused silica upon shock wave loading and unloading. Gas-gun flyer plate impact and explosively driven tests have been conducted to investigate the dynamic behaviour of this material. Hugoniot states and the Hugoniot Elastic Limit of LMJ fused silica have been obtained. These experimental data are useful for determining some constitutive model constants of the 'Crack-Model', a continuum tensile and compressive failure model with friction based. This model has been improved by taking into account nonlinear elasticity. The numerical results obtained by performing computations of the previous tests and some ballistic impact tests are discussed. The numerical comparisons with the experimental data show good agreement. Further developments to simulate the permanent densification and the solid-to-solid phase transformation of fused silica are required. (authors)

  2. FTA real-time transit information assessment : white paper on literature review of real-time transit information systems.

    Science.gov (United States)

    Real-time transit information systems are key technology applications within the transit industry designed to provide better customer service by disseminating timely and accurate information. Riders use this information to make various decisions abou...

  3. Facial Expression Emotion Detection for Real-Time Embedded Systems

    Directory of Open Access Journals (Sweden)

    Saeed Turabzadeh

    2018-01-01

    Full Text Available Recently, real-time facial expression recognition has attracted more and more research. In this study, an automatic facial expression real-time system was built and tested. Firstly, the system and model were designed and tested on a MATLAB environment followed by a MATLAB Simulink environment that is capable of recognizing continuous facial expressions in real-time with a rate of 1 frame per second and that is implemented on a desktop PC. They have been evaluated in a public dataset, and the experimental results were promising. The dataset and labels used in this study were made from videos, which were recorded twice from five participants while watching a video. Secondly, in order to implement in real-time at a faster frame rate, the facial expression recognition system was built on the field-programmable gate array (FPGA. The camera sensor used in this work was a Digilent VmodCAM — stereo camera module. The model was built on the Atlys™ Spartan-6 FPGA development board. It can continuously perform emotional state recognition in real-time at a frame rate of 30. A graphical user interface was designed to display the participant’s video in real-time and two-dimensional predict labels of the emotion at the same time.

  4. Combined Use of Ultrasound Elastography and B-Mode Sonography for Differentiation of Benign and Malignant Circumscribed Breast Masses.

    Science.gov (United States)

    Kim, Soo-Yeon; Park, Jeong Seon; Koo, Hye Ryoung

    2015-11-01

    To evaluate the diagnostic performance of combined B-mode sonography and ultrasound elastography for differentiation between benign and malignant breast masses with circumscribed margins. We analyzed 109 pathologically proven circumscribed breast masses. Two radiologists retrospectively reviewed B-mode sonograms and elastograms in consensus. Based on the American College of Radiology Breast Imaging Reporting and Data System, we determined categories of the masses on B-mode sonography. Elastographic scores were assessed by a 3-point scale (negative, 0; equivocal, 1; and positive, 2). When the elastographic score for a lesion was 0 or 2, we downgraded or upgraded the B-mode category, respectively; thus, the reclassified Breast Imaging Reporting and Data System category was defined as the "reclassification category." Mean category values for benign and malignant lesions were compared by a Student t test. The diagnostic performance of B-mode, elastographic, and reclassification assessments was compared by receiver operating characteristic curve analysis. The mean B-mode category (2.5 versus 1.7), elastographic score (1.7 versus 0.8), and reclassification category (3.2 versus 1.6) were significantly higher in malignant than benign lesions (P benign and malignant circumscribed breast masses, combined use of B-mode sonography and elastography could provide a better diagnostic performance than B-mode sonography alone. © 2015 by the American Institute of Ultrasound in Medicine.

  5. 30 CFR 56.12036 - Fuse removal or replacement.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fuse removal or replacement. 56.12036 Section 56.12036 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12036 Fuse removal or replacement. Fuses shall not be removed or replaced by hand in an energized...

  6. Energy efficient approach for transient fault recovery in real time ...

    African Journals Online (AJOL)

    DR OKE

    Keywords: DVS, Fault tolerance, Real Time System, Transient Fault. ... in which missing the deadline may cause a failure and soft real time system, ..... Pillai, P., Shin, K., Real-time dynamic voltage scaling for low-power embedded operating ...

  7. Boat, wake, and wave real-time simulation

    Science.gov (United States)

    Świerkowski, Leszek; Gouthas, Efthimios; Christie, Chad L.; Williams, Owen M.

    2009-05-01

    We describe the extension of our real-time scene generation software VIRSuite to include the dynamic simulation of small boats and their wakes within an ocean environment. Extensive use has been made of the programmabilty available in the current generation of GPUs. We have demonstrated that real-time simulation is feasible, even including such complexities as dynamical calculation of the boat motion, wake generation and calculation of an FFTgenerated sea state.

  8. A Distributed Computing Network for Real-Time Systems.

    Science.gov (United States)

    1980-11-03

    7 ) AU2 o NAVA TUNDEWATER SY$TEMS CENTER NEWPORT RI F/G 9/2 UIS RIBUT E 0 COMPUTIN G N LTWORK FOR REAL - TIME SYSTEMS .(U) UASSIFIED NOV Al 6 1...MORAIS - UT 92 dLEVEL c A Distributed Computing Network for Real - Time Systems . 11 𔃺-1 Gordon E/Morson I7 y tm- ,r - t "en t As J 2 -p .. - 7 I’ cNaval...NUMBER TD 5932 / N 4. TITLE mand SubotI. S. TYPE OF REPORT & PERIOD COVERED A DISTRIBUTED COMPUTING NETWORK FOR REAL - TIME SYSTEMS 6. PERFORMING ORG

  9. Is sonography performed by the rheumatologist as useful as arthrography executed by the radiologist for the assessment of full thickness rotator cuff tears?

    NARCIS (Netherlands)

    Swen, W. A.; Jacobs, J. W.; Neve, W. C.; Bal, D.; Bijlsma, J. W.

    1998-01-01

    Sonography and arthrography are techniques used to detect rotator cuff tears (RCT). The diagnostic value of sonography executed by a rheumatologist versus that of arthrography performed by a radiologist for assessment of RCT was investigated among patients with unilateral chronic shoulder complaints

  10. Optimization of Partitioned Architectures to Support Soft Real-Time Applications

    DEFF Research Database (Denmark)

    Tamas-Selicean, Domitian; Pop, Paul

    2014-01-01

    In this paper we propose a new Tabu Search-based design optimization strategy for mixed-criticality systems implementing hard and soft real-time applications on the same platform. Our proposed strategy determined an implementation such that all hard real-time applications are schedulable and the ......In this paper we propose a new Tabu Search-based design optimization strategy for mixed-criticality systems implementing hard and soft real-time applications on the same platform. Our proposed strategy determined an implementation such that all hard real-time applications are schedulable...... and the quality of service of the soft real-time tasks is maximized. We have evaluated our strategy using an aerospace case study....

  11. Preoperative assessment of intestinal endometriosis: A comparison of transvaginal sonography with water-contrast in the rectum, transrectal sonography, and barium enema.

    Science.gov (United States)

    Bergamini, Valentino; Ghezzi, Fabio; Scarperi, Stefano; Raffaelli, Ricciarda; Cromi, Antonella; Franchi, Massimo

    2010-12-01

    To evaluate the accuracy of Transrectal Sonography (TRS) and a new technique, Transvaginal Sonography with Water-Contrast in the Rectum (RWC-TVS), in the diagnosis of rectosigmoid endometriosis, and the accuracy of Barium Enema (BE) and RWC-TVS in the detection of intestinal stenosis due to endometriosis. In a prospective study, we compared the findings of TRS and RWC-TVS performed before surgery with the operative and pathologic findings in 61 consecutive patients who underwent laparoscopy or laparotomy for suspected rectosigmoid endometriosis. The accuracy of BE and RWC-TVS in the detection of intestinal stenosis was evaluated comparing the radiologic and ultrasonographic results with the macroscopic findings at surgery and pathology. RWC-TVS diagnosed rectosigmoid endometriosis with the same accuracy of TRS and was equally efficient as BE in the detection of a significant intestinal lumen stenosis. For the diagnosis of rectosigmoid endometriosis the sensitivity, specificity, positive and negative predictive values of TRS and RWC-TVS were 88.2% and 96%, 80%, and 90%, 95.7%, and 98%, and 57.1% and 81.8%, respectively. For the detection of intestinal stenosis the sensitivity, specificity, positive and negative predictive values of BE and RWC-TVS were 93.7% and 87.5%, 94.2% and 91.4%, 88.2% and 82.3%, and 97% and 94.1%, respectively. RWC-TVS is a new, simple technique for a single-step and accurate preoperative assessment of rectosigmoid endometriosis.

  12. LHCb's Time-Real Alignment in RunII

    CERN Multimedia

    Batozskaya, Varvara

    2015-01-01

    LHCb has introduced a novel real-time detector alignment and calibration strategy for LHC Run 2. Data collected at the start of the fill will be processed in a few minutes and used to update the alignment, while the calibration constants will be evaluated for each run. This procedure will improve the quality of the online alignment. Critically, this new real-time alignment and calibration procedure allows identical constants to be used in the online and offline reconstruction, thus improving the correlation between triggered and offline selected events. This offers the opportunity to optimise the event selection in the trigger by applying stronger constraints. The required computing time constraints are met thanks to a new dedicated framework using the multi-core farm infrastructure for the trigger. The motivation for a real-time alignment and calibration of the LHCb detector is discussed from both the operational and physics performance points of view. Specific challenges of this novel configur...

  13. 30 CFR 57.6502 - Safety fuse.

    Science.gov (United States)

    2010-07-01

    ... blasthole detonates. (d) Fuse shall be cut and capped in dry locations. (e) Blasting caps shall be crimped... the primer and the explosive material are securely in place. (g) Safety fuse shall be ignited only... to be fired, electric initiation systems, igniter cord and connectors, or other nonelectric...

  14. 30 CFR 56.6502 - Safety fuse.

    Science.gov (United States)

    2010-07-01

    ... be cut and capped in dry locations. (e) Blasting caps shall be crimped to fuse only with implements... material are securely in place. (g) Safety fuse shall be ignited only with devices designed for that... initiation systems, igniter cord and connectors, or other nonelectric initiation systems shall be used...

  15. Color coded duplex sonography. Interdisciplinary vascular ultrasonography; Farbkodierte Duplexsonographie. Interdisziplinaerer vaskulaerer Ultraschall

    Energy Technology Data Exchange (ETDEWEB)

    Kubale, R. [Institut fuer Radiologie, Sonographie und Nuklearmedizin, Pirmasens (Germany); Stiegler, H. [Staedtisches Krankenhaus Schwabing, Muenchen (Germany). 7. Medizinische Abt.

    2002-07-01

    An interdisciplinary team of experts impart the state of the art in color coded duplex sonography applied for examination of all anatomic areas. Detailed information is given for every vascular area, describing the examination procedure, possible origins of mistakes or faults, and means to avoid them. In addition to the classical applications, eg. for examination of the extra- and intracranial vessels, vessels of the limbs, visceral vessels and the vessels of liver and kidney, there are chapters devoted to: haemodialysis shunts, arteriovenous malformations, duplex sonography of the penis, tumor vascularisation. (orig./CB) [German] Ein interdisziplinaeres Autorenteam vermittelt Ihnen den State of the Art der FKDS fuer alle anatomischen Regionen. Fuer jede der Gefaessregionen werden detaillierte Angaben zum Untersuchungsablauf, zu moeglichen Fehlerquellen und zu deren Vermeidung geboten. Neben den klassischen Anwendungen bei der Untersuchung - der extra- und intrakraniellen Gefaesse, - der Extremitaetengefaesse, - der viszeralen Gefaesse sowie der Gefaesse von Niere und Leber finden Sie Kapitel zu den Themen: Haemodialyseshunt, arteriovenoese Malformationen, Duplexsonographie des Penis und Tumorvaskularisation. (orig./AJ)

  16. Towards real-time regional earthquake simulation I: real-time moment tensor monitoring (RMT) for regional events in Taiwan

    Science.gov (United States)

    Lee, Shiann-Jong; Liang, Wen-Tzong; Cheng, Hui-Wen; Tu, Feng-Shan; Ma, Kuo-Fong; Tsuruoka, Hiroshi; Kawakatsu, Hitoshi; Huang, Bor-Shouh; Liu, Chun-Chi

    2014-01-01

    We have developed a real-time moment tensor monitoring system (RMT) which takes advantage of a grid-based moment tensor inversion technique and real-time broad-band seismic recordings to automatically monitor earthquake activities in the vicinity of Taiwan. The centroid moment tensor (CMT) inversion technique and a grid search scheme are applied to obtain the information of earthquake source parameters, including the event origin time, hypocentral location, moment magnitude and focal mechanism. All of these source parameters can be determined simultaneously within 117 s after the occurrence of an earthquake. The monitoring area involves the entire Taiwan Island and the offshore region, which covers the area of 119.3°E to 123.0°E and 21.0°N to 26.0°N, with a depth from 6 to 136 km. A 3-D grid system is implemented in the monitoring area with a uniform horizontal interval of 0.1° and a vertical interval of 10 km. The inversion procedure is based on a 1-D Green's function database calculated by the frequency-wavenumber (fk) method. We compare our results with the Central Weather Bureau (CWB) catalogue data for earthquakes occurred between 2010 and 2012. The average differences between event origin time and hypocentral location are less than 2 s and 10 km, respectively. The focal mechanisms determined by RMT are also comparable with the Broadband Array in Taiwan for Seismology (BATS) CMT solutions. These results indicate that the RMT system is realizable and efficient to monitor local seismic activities. In addition, the time needed to obtain all the point source parameters is reduced substantially compared to routine earthquake reports. By connecting RMT with a real-time online earthquake simulation (ROS) system, all the source parameters will be forwarded to the ROS to make the real-time earthquake simulation feasible. The RMT has operated offline (2010-2011) and online (since January 2012 to present) at the Institute of Earth Sciences (IES), Academia Sinica

  17. Real-Time Pore Pressure Detection: Indicators and Improved Methods

    Directory of Open Access Journals (Sweden)

    Jincai Zhang

    2017-01-01

    Full Text Available High uncertainties may exist in the predrill pore pressure prediction in new prospects and deepwater subsalt wells; therefore, real-time pore pressure detection is highly needed to reduce drilling risks. The methods for pore pressure detection (the resistivity, sonic, and corrected d-exponent methods are improved using the depth-dependent normal compaction equations to adapt to the requirements of the real-time monitoring. A new method is proposed to calculate pore pressure from the connection gas or elevated background gas, which can be used for real-time pore pressure detection. The pore pressure detection using the logging-while-drilling, measurement-while-drilling, and mud logging data is also implemented and evaluated. Abnormal pore pressure indicators from the well logs, mud logs, and wellbore instability events are identified and analyzed to interpret abnormal pore pressures for guiding real-time drilling decisions. The principles for identifying abnormal pressure indicators are proposed to improve real-time pore pressure monitoring.

  18. Real-time photorealistic stereoscopic rendering of fire

    Science.gov (United States)

    Rose, Benjamin M.; McAllister, David F.

    2007-02-01

    We propose a method for real-time photorealistic stereo rendering of the natural phenomenon of fire. Applications include the use of virtual reality in fire fighting, military training, and entertainment. Rendering fire in real-time presents a challenge because of the transparency and non-static fluid-like behavior of fire. It is well known that, in general, methods that are effective for monoscopic rendering are not necessarily easily extended to stereo rendering because monoscopic methods often do not provide the depth information necessary to produce the parallax required for binocular disparity in stereoscopic rendering. We investigate the existing techniques used for monoscopic rendering of fire and discuss their suitability for extension to real-time stereo rendering. Methods include the use of precomputed textures, dynamic generation of textures, and rendering models resulting from the approximation of solutions of fluid dynamics equations through the use of ray-tracing algorithms. We have found that in order to attain real-time frame rates, our method based on billboarding is effective. Slicing is used to simulate depth. Texture mapping or 2D images are mapped onto polygons and alpha blending is used to treat transparency. We can use video recordings or prerendered high-quality images of fire as textures to attain photorealistic stereo.

  19. OMPS Near Real-time Products Available Through NASA LANCE (Land Atmosphere Near Real-time Capability for EOS)

    Science.gov (United States)

    Warnock, A.; Durbin, P. B.; Cechini, M. F.; Masuoka, E.

    2017-12-01

    Near real-time (NRT) images from the NASA Ozone Mapping and Profiler Suite (OMPS) for sulfur dioxide, total column ozone and aerosol index products are now available through NASA's online Land Atmosphere Near real-time Capability for EOS (LANCE) system. Color palettes, image dimensions and data ranges have been aligned with the corresponding OMI products, allowing for direct comparison of OMPS NRT images with OMI NRT images already available in NASA Worldview. The images are delivered to LANCE within hours of satellite observation. LANCE NRT imagery can be interactively viewed through Worldview and the Global Imagery Browse Services (GIBS).

  20. Tumor vascularity of experimentally induced VX2 carcinoma in the rabbit thigh: evaluation with enhanced power doppler sonography and DSA correlated with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hoon; Han, Joon Koo; Chung, Jin Wook; Lee, Kyoung Ho; Kim, Se Hyung; Kim, Seog Joon; Choi, Byung Ihn; Chang, Kee Hyun [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2002-05-01

    To describe findings of enhanced power Doppler sonography and DSA in experimentally induced VX2 carcinomas in rabbit thigh and to correlate the imaging findings with the histopathologic features. A total of 30 VX2 carcinomas were implanted in rabbit thigh, and after conventional and enhanced power Doppler sonography and DSA, histopathologic examination was performed. Enhanced power Doppler sonography and DSA, were used to determine the distribution pattern of tumor vascularity; to assess its grade and the percentage of a tumor area occupied by vessels, conventional and enhanced power Doppler sonography, as well as DSA, were used. The grade of necrosis and the development of fibrovascular stroma and capsule were histopathologically determined. The findings of power Doppler sonography were compared with those of DSA and the imaging features were correlated with the histopathologic features. At enhanced power Doppler sonography, the signal was either avascular (n=9), peripheral (n=15) or diffuse (n=6), while at DSA, the corresponding totals were eight, fourteen and eight. There was statistically significant corelation between enhanced power Doppler sonogrpahy and DSA, both in their depiction of the distribution of patterns of tumor vascularity and as regards their findings of grade and percentage of vascular area. As determined by both conventional and enhanced power Doppler sonogrpahy, and by DSA, grade of necrosis and the development of fibrovascular stroma and a capsule correlated with grade and the percentage of vascular area. Experimentally induced VX2 carcinomas in rabbit thigh demonstrated various patterns of tumor vascularity, and the findings of enhanced power Doppler sonography correlated with those of DSA. Tumor vascularity, as demonstrated by two imaging modalities, correlated closely with grade of necrosis and the development of fibrovascular stroma and a capsule, as revealed by histopathologic examination.

  1. Tumor vascularity of experimentally induced VX2 carcinoma in the rabbit thigh: evaluation with enhanced power doppler sonography and DSA correlated with histopathologic findings

    International Nuclear Information System (INIS)

    Kim, Young Hoon; Han, Joon Koo; Chung, Jin Wook; Lee, Kyoung Ho; Kim, Se Hyung; Kim, Seog Joon; Choi, Byung Ihn; Chang, Kee Hyun

    2002-01-01

    To describe findings of enhanced power Doppler sonography and DSA in experimentally induced VX2 carcinomas in rabbit thigh and to correlate the imaging findings with the histopathologic features. A total of 30 VX2 carcinomas were implanted in rabbit thigh, and after conventional and enhanced power Doppler sonography and DSA, histopathologic examination was performed. Enhanced power Doppler sonography and DSA, were used to determine the distribution pattern of tumor vascularity; to assess its grade and the percentage of a tumor area occupied by vessels, conventional and enhanced power Doppler sonography, as well as DSA, were used. The grade of necrosis and the development of fibrovascular stroma and capsule were histopathologically determined. The findings of power Doppler sonography were compared with those of DSA and the imaging features were correlated with the histopathologic features. At enhanced power Doppler sonography, the signal was either avascular (n=9), peripheral (n=15) or diffuse (n=6), while at DSA, the corresponding totals were eight, fourteen and eight. There was statistically significant corelation between enhanced power Doppler sonogrpahy and DSA, both in their depiction of the distribution of patterns of tumor vascularity and as regards their findings of grade and percentage of vascular area. As determined by both conventional and enhanced power Doppler sonogrpahy, and by DSA, grade of necrosis and the development of fibrovascular stroma and a capsule correlated with grade and the percentage of vascular area. Experimentally induced VX2 carcinomas in rabbit thigh demonstrated various patterns of tumor vascularity, and the findings of enhanced power Doppler sonography correlated with those of DSA. Tumor vascularity, as demonstrated by two imaging modalities, correlated closely with grade of necrosis and the development of fibrovascular stroma and a capsule, as revealed by histopathologic examination

  2. Diagnosis of Pentalogy of Cantrell in the First Trimester Using Transvaginal Sonography and Color Doppler

    Directory of Open Access Journals (Sweden)

    Ayşe Figen Türkçapar

    2015-01-01

    Full Text Available We report the prenatal diagnosis of Cantrell syndrome in the first trimester. During a routine transabdominal ultrasonographic examination, a midline supraumbilical abdominal wall defect including herniated liver and ectopia cordis with a large omphalocele containing the intestines and cystic hygroma was incidentally identified at the 12th week of gestation. A transvaginal sonography examination revealed a severe lumbosacral scoliosis in addition to the inability to visualize the abdominal aorta which was indicative of a severe intracardiac defect. The parents opted for pregnancy to be terminated. In this case report, we discuss the complementary role of transvaginal sonography and Doppler imaging in the diagnosis of Cantrell syndrome in early pregnancy.

  3. Real-time radiography at the NECTAR facility

    International Nuclear Information System (INIS)

    Buecherl, T.; Lierse von Gostomski, Ch.

    2011-01-01

    A feasibility study has shown that real-time radiography using fission neutrons is possible at the NECTAR facility, when using an improved detection system for fast variations (Buecherl et al., 2009 ). Continuing this study, real-time measurements of slowly varying processes like the water uptake in medium sized trunks (diameter about 12 cm) and of slow periodic processes (e.g. a slowly rotating iron disk) are investigated successfully using the existing detection system.

  4. Real-time radiography at the NECTAR facility

    Science.gov (United States)

    Bücherl, T.; Lierse von Gostomski, Ch.

    2011-09-01

    A feasibility study has shown that real-time radiography using fission neutrons is possible at the NECTAR facility, when using an improved detection system for fast variations (Bücherl et al., 2009 [1]). Continuing this study, real-time measurements of slowly varying processes like the water uptake in medium sized trunks (diameter about 12 cm) and of slow periodic processes (e.g. a slowly rotating iron disk) are investigated successfully using the existing detection system.

  5. Real-time radiography at the NECTAR facility

    Energy Technology Data Exchange (ETDEWEB)

    Buecherl, T., E-mail: thomas.buecherl@radiochemie.de [Lehrstuhl fuer Radiochemie (RCM), Technische Universitaet Muenchen (TUM), Walther-Meissner-Str. 3, 85748 Garching (Germany); Lierse von Gostomski, Ch. [Lehrstuhl fuer Radiochemie (RCM), Technische Universitaet Muenchen (TUM), Walther-Meissner-Str. 3, 85748 Garching (Germany)

    2011-09-21

    A feasibility study has shown that real-time radiography using fission neutrons is possible at the NECTAR facility, when using an improved detection system for fast variations (Buecherl et al., 2009 ). Continuing this study, real-time measurements of slowly varying processes like the water uptake in medium sized trunks (diameter about 12 cm) and of slow periodic processes (e.g. a slowly rotating iron disk) are investigated successfully using the existing detection system.

  6. Research of real-time performance based on VxWorks embedded system

    International Nuclear Information System (INIS)

    Liu Daming; Li Haiming

    2011-01-01

    In the research of mechanism and heating efficiency of Ion Cyclotron Range of Frequency (ICRF) heating, data acquisition system with high real-time performance needed. By the means of system logic analyzer, SPY and other relevant software on VxWorks embedded operating system for real-time testing gives real-time data of the system. Real-time level to achieve balances used time and processor idle time, real-time data acquisition, and minimize the interference of external to the system, ensure the system work in its own set of scheduling trajectory. Interrupt switching time and task context switching time meet the system requirements. (authors)

  7. Comparison of findings of spontaneous splenorenal shunt in color Doppler sonography with multislice CT scan (64 slices) in liver transplant candidates

    Energy Technology Data Exchange (ETDEWEB)

    Bagheri, Mohammadhadi, E-mail: Bagherimh@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Hajati, Azadeh, E-mail: azadeh.hajati@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Hosseini, Mohammadkazem, E-mail: hosseiniaslm@sums.ac.ir [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Ostad, Seyed Pouria, E-mail: Pouria.Ostad@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of)

    2012-09-15

    Background: Liver transplantation is the only definite treatment for end stage liver disease and it has high costs for the medical system so decreasing its complication and increasing its effectiveness is crucial. One of the factors that affect liver transplantation is the presence of spontaneous splenorenal shunt. Its diagnosis is mainly overlooked in pre-liver transplant patients. Main modality for its diagnosis is multislice CT scan however this is more expensive than sonography. Also, it exposes the patients to ionizing radiation. Considering the advantages of color Doppler ultrasound, studies to determine the sensitivity and specificity for detection of spontaneous splenorenal shunt is essential. Materials and methods: In our study 70 cirrhotic patients who were referred by liver transplant surgeons for evaluation of abdomen by CT and sonograhy were assessed for presence of spontaneous splenorenal shunt, left adrenal varix and left renal vein diameter and velocity and sensitivity and specificity of both modalities were checked. Patients in whom left renal vein could not evaluated by sonography and patients with splenectomy and nutcracker syndrome were excluded. Results: In the point of 10 mm diameter of left renal vein in CT scan there was 78.6% sensitivity and 67.9% specificity for the presence of spontaneous splenorenal shunt. Left adrenal varix in CT had sensitivity of 71.4%, specificity of 100%, and positive predictive value of 100% and negative predictive value of 70% and varix below spleen in CT had sensitivity of 54.8%, specificity of 96.4%, and positive predictive value of 95.8% and negative predictive value of 58.7% for the presence of spontaneous splenorenal shunt. In the point of 8 mm diameter of left renal vein in sonography there was 66.7% sensitivity and 85.7% specificity for the presence of spontaneous splenorenal shunt. For the velocity of more than 35 cm/s of left renal vein in sonography there was 61.9% sensitivity and 82.1% specificity for

  8. Real time ray tracing of skeletal implicit surfaces

    DEFF Research Database (Denmark)

    Rouiller, Olivier; Bærentzen, Jakob Andreas

    Modeling and rendering in real time is usually done via rasterization of polygonal meshes. We present a method to model with skeletal implicit surfaces and an algorithm to ray trace these surfaces in real time in the GPU. Our skeletal representation of the surfaces allows to create smooth models...

  9. Multiresource allocation and scheduling for periodic soft real-time applications

    Science.gov (United States)

    Gopalan, Kartik; Chiueh, Tzi-cker

    2001-12-01

    Real-time applications that utilize multiple system resources, such as CPU, disks, and network links, require coordinated scheduling of these resources in order to meet their end-to-end performance requirements. Most state-of-the-art operating systems support independent resource allocation and deadline-driven scheduling but lack coordination among multiple heterogeneous resources. This paper describes the design and implementation of an Integrated Real-time Resource Scheduler (IRS) that performs coordinated allocation and scheduling of multiple heterogeneous resources on the same machine for periodic soft real-time application. The principal feature of IRS is a heuristic multi-resource allocation algorithm that reserves multiple resources for real-time applications in a manner that can maximize the number of applications admitted into the system in the long run. At run-time, a global scheduler dispatches the tasks of the soft real-time application to individual resource schedulers according to the precedence constraints between tasks. The individual resource schedulers, which could be any deadline based schedulers, can make scheduling decisions locally and yet collectively satisfy a real-time application's performance requirements. The tightness of overall timing guarantees is ultimately determined by the properties of individual resource schedulers. However, IRS maximizes overall system resource utilization efficiency by coordinating deadline assignment across multiple tasks in a soft real-time application.

  10. Real-Time Forecasting Revisited: Letting the Data Decide

    OpenAIRE

    Jackson Kitchen; John Kitchen

    2013-01-01

    Real-time GDP forecasting, also often known as “nowcasting,” produces estimates for current-quarter real GDP growth, typically based on a centered value from a set of estimates from incoming indicators. These real-time measures are usually intended to be data-based and to not be based on forecaster judgment or add factors. Even so, estimation methodologies in this research area—and prior versions of the system we use—typically have been constrained by using various “fixed” relationships, such...

  11. Fusing inertial sensor data in an extended Kalman filter for 3D camera tracking.

    Science.gov (United States)

    Erdem, Arif Tanju; Ercan, Ali Özer

    2015-02-01

    In a setup where camera measurements are used to estimate 3D egomotion in an extended Kalman filter (EKF) framework, it is well-known that inertial sensors (i.e., accelerometers and gyroscopes) are especially useful when the camera undergoes fast motion. Inertial sensor data can be fused at the EKF with the camera measurements in either the correction stage (as measurement inputs) or the prediction stage (as control inputs). In general, only one type of inertial sensor is employed in the EKF in the literature, or when both are employed they are both fused in the same stage. In this paper, we provide an extensive performance comparison of every possible combination of fusing accelerometer and gyroscope data as control or measurement inputs using the same data set collected at different motion speeds. In particular, we compare the performances of different approaches based on 3D pose errors, in addition to camera reprojection errors commonly found in the literature, which provides further insight into the strengths and weaknesses of different approaches. We show using both simulated and real data that it is always better to fuse both sensors in the measurement stage and that in particular, accelerometer helps more with the 3D position tracking accuracy, whereas gyroscope helps more with the 3D orientation tracking accuracy. We also propose a simulated data generation method, which is beneficial for the design and validation of tracking algorithms involving both camera and inertial measurement unit measurements in general.

  12. Expert systems for real-time monitoring and fault diagnosis

    Science.gov (United States)

    Edwards, S. J.; Caglayan, A. K.

    1989-01-01

    Methods for building real-time onboard expert systems were investigated, and the use of expert systems technology was demonstrated in improving the performance of current real-time onboard monitoring and fault diagnosis applications. The potential applications of the proposed research include an expert system environment allowing the integration of expert systems into conventional time-critical application solutions, a grammar for describing the discrete event behavior of monitoring and fault diagnosis systems, and their applications to new real-time hardware fault diagnosis and monitoring systems for aircraft.

  13. Large holographic displays for real-time applications

    Science.gov (United States)

    Schwerdtner, A.; Häussler, R.; Leister, N.

    2008-02-01

    Holography is generally accepted as the ultimate approach to display three-dimensional scenes or objects. Principally, the reconstruction of an object from a perfect hologram would appear indistinguishable from viewing the corresponding real-world object. Up to now two main obstacles have prevented large-screen Computer-Generated Holograms (CGH) from achieving a satisfactory laboratory prototype not to mention a marketable one. The reason is a small cell pitch CGH resulting in a huge number of hologram cells and a very high computational load for encoding the CGH. These seemingly inevitable technological hurdles for a long time have not been cleared limiting the use of holography to special applications, such as optical filtering, interference, beam forming, digital holography for capturing the 3-D shape of objects, and others. SeeReal Technologies has developed a new approach for real-time capable CGH using the socalled Tracked Viewing Windows technology to overcome these problems. The paper will show that today's state of the art reconfigurable Spatial Light Modulators (SLM), especially today's feasible LCD panels are suited for reconstructing large 3-D scenes which can be observed from large viewing angles. For this to achieve the original holographic concept of containing information from the entire scene in each part of the CGH has been abandoned. This substantially reduces the hologram resolution and thus the computational load by several orders of magnitude making thus real-time computation possible. A monochrome real-time prototype measuring 20 inches has been built and demonstrated at last year's SID conference and exhibition 2007 and at several other events.

  14. The Raptor Real-Time Processing Architecture

    Science.gov (United States)

    Galassi, M.; Starr, D.; Wozniak, P.; Brozdin, K.

    The primary goal of Raptor is ambitious: to identify interesting optical transients from very wide field of view telescopes in real time, and then to quickly point the higher resolution Raptor ``fovea'' cameras and spectrometer to the location of the optical transient. The most interesting of Raptor's many applications is the real-time search for orphan optical counterparts of Gamma Ray Bursts. The sequence of steps (data acquisition, basic calibration, source extraction, astrometry, relative photometry, the smarts of transient identification and elimination of false positives, telescope pointing feedback, etc.) is implemented with a ``component'' approach. All basic elements of the pipeline functionality have been written from scratch or adapted (as in the case of SExtractor for source extraction) to form a consistent modern API operating on memory resident images and source lists. The result is a pipeline which meets our real-time requirements and which can easily operate as a monolithic or distributed processing system. Finally, the Raptor architecture is entirely based on free software (sometimes referred to as ``open source'' software). In this paper we also discuss the interplay between various free software technologies in this type of astronomical problem.

  15. Real-Time Operating System/360

    Science.gov (United States)

    Hoffman, R. L.; Kopp, R. S.; Mueller, H. H.; Pollan, W. D.; Van Sant, B. W.; Weiler, P. W.

    1969-01-01

    RTOS has a cost savings advantage for real-time applications, such as those with random inputs requiring a flexible data routing facility, display systems simplified by a device independent interface language, and complex applications needing added storage protection and data queuing.

  16. Real Time Fire Reconnaissance Satellite Monitoring System Failure Model

    Science.gov (United States)

    Nino Prieto, Omar Ariosto; Colmenares Guillen, Luis Enrique

    2013-09-01

    In this paper the Real Time Fire Reconnaissance Satellite Monitoring System is presented. This architecture is a legacy of the Detection System for Real-Time Physical Variables which is undergoing a patent process in Mexico. The methodologies for this design are the Structured Analysis for Real Time (SA- RT) [8], and the software is carried out by LACATRE (Langage d'aide à la Conception d'Application multitâche Temps Réel) [9,10] Real Time formal language. The system failures model is analyzed and the proposal is based on the formal language for the design of critical systems and Risk Assessment; AltaRica. This formal architecture uses satellites as input sensors and it was adapted from the original model which is a design pattern for physical variation detection in Real Time. The original design, whose task is to monitor events such as natural disasters and health related applications, or actual sickness monitoring and prevention, as the Real Time Diabetes Monitoring System, among others. Some related work has been presented on the Mexican Space Agency (AEM) Creation and Consultation Forums (2010-2011), and throughout the International Mexican Aerospace Science and Technology Society (SOMECYTA) international congress held in San Luis Potosí, México (2012). This Architecture will allow a Real Time Fire Satellite Monitoring, which will reduce the damage and danger caused by fires which consumes the forests and tropical forests of Mexico. This new proposal, permits having a new system that impacts on disaster prevention, by combining national and international technologies and cooperation for the benefit of humankind.

  17. Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: experience with 59 implants.

    Science.gov (United States)

    Ahn, C Y; DeBruhl, N D; Gorczyca, D P; Shaw, W W; Bassett, L W

    1994-10-01

    With the current controversy regarding the safety of silicone implants, the detection and evaluation of implant rupture are causing concern for both plastic surgeons and patients. Our study obtained comparative value analysis of mammography, sonography, and magnetic resonance imaging (MRI) in the detection of silicone implant rupture. Twenty-nine symptomatic patients (total of 59 silicone implants) were entered into the study. Intraoperative findings revealed 21 ruptured implants (36 percent). During physical examination, a positive "squeeze test" was highly suggestive of implant rupture. Mammograms were obtained of 51 implants (sensitivity 11 percent, specificity 89 percent). Sonography was performed on 57 implants (sensitivity 70 percent, specificity 92 percent). MRI was performed on 55 implants (sensitivity 81 percent, specificity 92 percent). Sonographically, implant rupture is demonstrated by the "stepladder sign." Double-lumen implants may appear as false-positive results for rupture on sonography. On MRI, the "linguine sign" represents disrupted fragments of a ruptured implant. The most reliable imaging modality for implant rupture detection is MRI, followed by sonogram. Mammogram is the least reliable. Our study supports the clinical indication and diagnostic value of sonogram and MRI in the evaluation of symptomatic breast implant patients.

  18. Real time equilibrium reconstruction for tokamak discharge control

    International Nuclear Information System (INIS)

    Ferron, J.R.; Walker, M.L.; Lao, L.L.; St John, H.E.; Humphreys, D.A.; Leuer, J.A.

    1998-01-01

    A practical method for performing a tokamak equilibrium reconstruction in real time for arbitrary time varying discharge shapes and current profiles is described. An approximate solution to the Grad-Shafranov equilibrium relation is found which best fits the diagnostic measurements. Thus, a solution for the spatial distribution of poloidal flux and toroidal current density is available in real time that is consistent with plasma force balance, allowing accurate evaluation of parameters such as discharge shape and safety factor profile. The equilibrium solutions are produced at a rate sufficient for discharge control. This equilibrium reconstruction algorithm has been implemented on the digital plasma control system for the DIII-D tokamak. The first application of real time equilibrium reconstruction to discharge shape control is described. (author)

  19. Issues Involved in Developing Ada Real-Time Systems

    Science.gov (United States)

    1989-02-15

    expensive modifications to the compiler or Ada runtime system to fit a particular application. Whether we can solve the problems of programming real - time systems in...lock in solutions to problems that are not yet well understood in standards as rigorous as the Ada language. Moreover, real - time systems typically have

  20. Real-time disk scheduling in a mixed-media file system

    NARCIS (Netherlands)

    Bosch, H.G.P.; Mullender, Sape J.

    2000-01-01

    This paper presents our real-time disk scheduler called the Delta L scheduler, which optimizes unscheduled best-effort disk requests by giving priority to best-effort disk requests while meeting real-time request deadlines. Our scheduler tries to execute real-time disk requests as much as possible

  1. Real time urbanism

    Directory of Open Access Journals (Sweden)

    Ana Ruiz Varona

    2012-12-01

    Full Text Available Nowadays, given the technological revolution of the society of information, the administrative management of the cities faces a new problem not as related to the projection of the urban space as to the capacity of controlling and measuring the process of direct and centralized production of the cities by part of some non-homogeneous social multitudes, in a hyper-accelerated time towards instantaneity. Against libertarian apologies of the new “participative urbanisms”, the article puts forward a discourse that shows the lost associated to the new problem of temporal instantaneity. In this regard we claim new process of mediation that allow administrations and urbanist monitoring the production of the city. To that end, a previous and necessary step will be the redefinition of the role of a new real time urbanist.

  2. Polycistronic transcription of fused cassettes and identification of translation initiation signals in an unusual gene cassette array from Pseudomonas aeruginosa [version 3; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Érica L. Fonseca

    2015-11-01

    Full Text Available The gene cassettes found in class 1 integrons are generally promoterless units composed by an open reading frame (ORF, a short 5’ untranslated region (UTR and a 3’ recombination site (attC. Fused gene cassettes are generated by partial or total loss of the attC from the first cassette in an array, creating, in some cases, a fusion with the ORF from the next cassette. These structures are rare and little is known about their mechanisms of mobilization and expression. The aim of this study was to evaluate the dynamic of mobilization and transcription of the gcu14-blaGES-1/aacA4 gene cassette array, which harbours a fused gene cassette represented by blaGES-1/aacA4. The cassette array was analyzed by Northern blot and real-time reverse transcription-polymerase chain reaction (RT-PCR in order to assess the transcription mechanism of blaGES-1/aacA4 fused cassette. Also, inverse polymerase chain reactions (PCR were performed to detect the free circular forms of gcu14, blaGES-1 and aacA4. The Northern blot and real time RT-PCR revealed a polycistronic transcription, in which the fused cassette blaGES-1/aacA4 is transcribed as a unique gene, while gcu14 (with a canonical attC recombination site has a monocistronic transcription. The gcu14 cassette, closer to the weak configuration of cassette promoter (PcW, had a higher transcription level than blaGES-1/aacA4, indicating that the cassette position affects the transcript amounts. The presence of ORF-11 at attI1, immediately preceding gcu14, and of a Shine-Dalgarno sequence upstream blaGES-1/aacA4 composes a scenario for the occurrence of array translation. Inverse PCR generated amplicons corresponding to gcu14, gcu14-aacA4 and gcu14-blaGES-1/aacA4 free circular forms, but not to blaGES-1 and aacA4 alone, indicating that the GES-1 truncated attC is not substrate of integrase activity and that these genes are mobilized together as a unique cassette. This study was original in showing the transcription

  3. Real-Time Imaging System for the OpenPET

    Science.gov (United States)

    Tashima, Hideaki; Yoshida, Eiji; Kinouchi, Shoko; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo; Suga, Mikio; Haneishi, Hideaki; Yamaya, Taiga

    2012-02-01

    The OpenPET and its real-time imaging capability have great potential for real-time tumor tracking in medical procedures such as biopsy and radiation therapy. For the real-time imaging system, we intend to use the one-pass list-mode dynamic row-action maximum likelihood algorithm (DRAMA) and implement it using general-purpose computing on graphics processing units (GPGPU) techniques. However, it is difficult to make consistent reconstructions in real-time because the amount of list-mode data acquired in PET scans may be large depending on the level of radioactivity, and the reconstruction speed depends on the amount of the list-mode data. In this study, we developed a system to control the data used in the reconstruction step while retaining quantitative performance. In the proposed system, the data transfer control system limits the event counts to be used in the reconstruction step according to the reconstruction speed, and the reconstructed images are properly intensified by using the ratio of the used counts to the total counts. We implemented the system on a small OpenPET prototype system and evaluated the performance in terms of the real-time tracking ability by displaying reconstructed images in which the intensity was compensated. The intensity of the displayed images correlated properly with the original count rate and a frame rate of 2 frames per second was achieved with average delay time of 2.1 s.

  4. Effects of computing time delay on real-time control systems

    Science.gov (United States)

    Shin, Kang G.; Cui, Xianzhong

    1988-01-01

    The reliability of a real-time digital control system depends not only on the reliability of the hardware and software used, but also on the speed in executing control algorithms. The latter is due to the negative effects of computing time delay on control system performance. For a given sampling interval, the effects of computing time delay are classified into the delay problem and the loss problem. Analysis of these two problems is presented as a means of evaluating real-time control systems. As an example, both the self-tuning predicted (STP) control and Proportional-Integral-Derivative (PID) control are applied to the problem of tracking robot trajectories, and their respective effects of computing time delay on control performance are comparatively evaluated. For this example, the STP (PID) controller is shown to outperform the PID (STP) controller in coping with the delay (loss) problem.

  5. A New Generation of Real-Time Systems in the JET Tokamak

    Science.gov (United States)

    Alves, Diogo; Neto, Andre C.; Valcarcel, Daniel F.; Felton, Robert; Lopez, Juan M.; Barbalace, Antonio; Boncagni, Luca; Card, Peter; De Tommasi, Gianmaria; Goodyear, Alex; Jachmich, Stefan; Lomas, Peter J.; Maviglia, Francesco; McCullen, Paul; Murari, Andrea; Rainford, Mark; Reux, Cedric; Rimini, Fernanda; Sartori, Filippo; Stephen, Adam V.; Vega, Jesus; Vitelli, Riccardo; Zabeo, Luca; Zastrow, Klaus-Dieter

    2014-04-01

    Recently, a new recipe for developing and deploying real-time systems has become increasingly adopted in the JET tokamak. Powered by the advent of x86 multi-core technology and the reliability of JET's well established Real-Time Data Network (RTDN) to handle all real-time I/O, an official Linux vanilla kernel has been demonstrated to be able to provide real-time performance to user-space applications that are required to meet stringent timing constraints. In particular, a careful rearrangement of the Interrupt ReQuests' (IRQs) affinities together with the kernel's CPU isolation mechanism allows one to obtain either soft or hard real-time behavior depending on the synchronization mechanism adopted. Finally, the Multithreaded Application Real-Time executor (MARTe) framework is used for building applications particularly optimised for exploring multi-core architectures. In the past year, four new systems based on this philosophy have been installed and are now part of JET's routine operation. The focus of the present work is on the configuration aspects that enable these new systems' real-time capability. Details are given about the common real-time configuration of these systems, followed by a brief description of each system together with results regarding their real-time performance. A cycle time jitter analysis of a user-space MARTe based application synchronizing over a network is also presented. The goal is to compare its deterministic performance while running on a vanilla and on a Messaging Real time Grid (MRG) Linux kernel.

  6. Use and effectiveness of scintigraphy, sonography and angiography in circumscribed disease of the liver

    Energy Technology Data Exchange (ETDEWEB)

    Pokieser, H; Czembirek, H; Mayrhofer, H; Urbanek, A; Kahn, P; Weiss, W; Base, W [Ludwig-Boltzmann-Institut fuer Radiologisch-Physikalische Tumordiagnostik, Vienna (Austria); Vienna Univ. (Austria). 1. Medizinische Klinik; Hanuschkrankenhaus, Vienna (Austria). 1. Medizinische Abt.)

    1977-02-01

    The effectiveness of scintigraphy, sonography and angiography is compared in a material of 140 cases of circumscribed disease of the liver. Typical clinical starting points are defined as points of reference of the diagnostic techniques. Clinical diagnosis is very safe in cases of secondary blastoma and hepatocellular carcinoma of the liver. Since the great majority of these conditions cause space-occupying lesions of the liver, problems of radiologic diagnosis are confined to the smaller number of clinically ill-defined lesions. For the diagnosis of secondary blastomas and cystic processes of all kinds, scintigraphy and sonography are not improved by angiography. Solid space-occupying lesions of unknown origin, however, can only be recognized with angiography. Histology of both benign and malignant processes will be correct in more than 90% of cases.

  7. Real Time Structured Light and Applications

    DEFF Research Database (Denmark)

    Wilm, Jakob

    Structured light scanning is a versatile method for 3D shape acquisition. While much faster than most competing measurement techniques, most high-end structured light scans still take in the order of seconds to complete. Low-cost sensors such as Microsoft Kinect and time of flight cameras have made......, increased processing power, and methods presented in this thesis, it is possible to perform structured light scans in real time with 20 depth measurements per second. This offers new opportunities for studying dynamic scenes, quality control, human-computer interaction and more. This thesis discusses...... several aspects of real time structured light systems and presents contributions within calibration, scene coding and motion correction aspects. The problem of reliable and fast calibration of such systems is addressed with a novel calibration scheme utilising radial basis functions [Contribution B...

  8. Real-Time Scheduling for Preventing Information Leakage with Preemption Overheads

    Directory of Open Access Journals (Sweden)

    BAEK, H.

    2017-05-01

    Full Text Available Real-time systems (RTS are characterized by tasks executing in a timely manner to meet its deadlines as a real-time constraint. Most studies of RTS have focused on these criteria as primary design points. However, recent increases in security threats to various real-time systems have shown that enhanced security support must be included as an important design point, retro-fitting such support to existing systems as necessary. In this paper, we propose a new pre-flush technique referred to as flush task reservation for FP scheduling (FTR-FP to conditionally sanitize the state of resources shared by real-time tasks by invoking a flush task (FT in order to mitigate information leakage/corruption of real-time systems. FTR-FP extends existing works exploiting FTs to be applicable more general scheduling algorithms and security model. We also propose modifications to existing real-time scheduling algorithms to implement a pre-flush technique as a security constraint, and analysis technique to verify schedulability of the real-time scheduling. For better analytic capability, our analysis technique provides a count of the precise number of preemptions that a task experiences offline. Our evaluation results demonstrate that our proposed schedulability analysis improves the performance of existing scheduling algorithms in terms of schedulability and preemption cost.

  9. MRI, CT, and sonography in the preoperative evaluation of primary tumor extension in malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Layer, G.; Steudel, A.; Schild, H.H.; Schmitteckert, H.; Tuengerthal, S.; Schirren, J.; Kaick, G. van

    1999-01-01

    Purpose: Evaluation of the diagnostic value of the imaging modalities computed tomography (CT), magnetic resonance imaging (MRI), and thoracic sonography in the preoperative staging of malignant pleural mesothelioma. Results: The accuracy rates for CT were 85%, 98%, 83%, 73%, 71%, and 83%. MRI had an accuracy of 71%, 92%, 71%, 83%, 71%, and 96%, the thoracic ultrasound examinations of 76%, 63%, 51%, 60%, 71% and 89%. Conclusions: According to these results CT remains the method of choice in the preoperative assessment of T-stage of malignant pleural mesothelioma. MRI is of nearly the same value, but is not a must. Sonography may be supplementary method for operation planning. (orig./AJ) [de

  10. Fetal tracheolaryngeal airway obstruction: prenatal evaluation by sonography and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Courtier, Jesse; Poder, Liina; Wang, Zhen J.; Westphalen, Antonio C.; Yeh, Benjamin M.; Coakley, Fergus V. [University of California San Francisco, Department of Radiology, San Francisco, CA (United States)

    2010-11-15

    We reviewed the sonographic and MRI findings of tracheolaryngeal obstruction in the fetus. Conditions that can cause tracheolaryngeal obstruction include extrinsic causes such as lymphatic malformation, cervical teratoma and vascular rings and intrinsic causes such as congenital high airway obstruction syndrome (CHAOS). Accurate distinction of these conditions by sonography or MRI can help facilitate parental counseling and management, including the decision to utilize the ex utero intrapartum treatment (EXIT) procedure. (orig.)

  11. 76 FR 42536 - Real-Time System Management Information Program

    Science.gov (United States)

    2011-07-19

    ...-Time System Management Information Program AGENCY: Federal Highway Administration (FHWA), DOT. ACTION... Real-Time System Management Information Program and general information about current and planned... establishing requirements for the Real-Time System Management Information Program on November 8, 2010, at 75 FR...

  12. 75 FR 68418 - Real-Time System Management Information Program

    Science.gov (United States)

    2010-11-08

    ...-Time System Management Information Program AGENCY: Federal Highway Administration (FHWA), DOT. ACTION...) to establish a Real-Time System Management Information Program that provides, in all States, the... traveler information. The purposes of the Real-Time System Management Information Program are to: (1...

  13. Data processing system for real-time control

    International Nuclear Information System (INIS)

    Oasa, K.; Mochizuki, O.; Toyokawa, R.; Yahiro, K.

    1983-01-01

    Real-time control, for large Tokamak JT-60, requires various data processings between diagnostic devices to control system. These processings require to high speed performance so that it aims at giving information necessary for feedback control during discharges. Then, the architecture of this system has hierachical structure of processors. These processors are connected each other by the CAMAC modules and the optical communication network, which is the 5 M bytes/second CAMAC serial highway. This system has two kinds of intelligences for this purpose. One is ACM-PU pairs in some torus hall crates which has a microcomputerized auxiliary controller and a preprocessing unit. Other is real-time processor which has a minicomputer and preprocessing unit. Most of the real-time processing, for example Abel inversion are characteristic to the diagnostic devices. Such a processing is carried out by an ACM-PU pair in the crate dedicated to the diagnostic device. Some processings, however, are also necessary which compute secondary parameters as functions of primary parameters. A typical example is Zeff, which is a function of Te, Ne and bremsstrahluny intensity. The real-time processor is equipped for such secondary processings and transfer the results. Preprocessing unit -PU- attached to ACM and real-time processor contains a signal processor, which executes in parallel such function as move, add and multiply during one micro-instruction cycle of 200 nsec. According to the progress of the experiment, more high speed processing are required, so the authors developed the PU-X module that contains multi signal processors. After a shot, inter-shot-processor which consists of general-purpose computers, gathers data into the database, then analyze them, and improve these processes to more effective

  14. Visualization of the Origin of the Vertebral Arteries with Color Doppler Sonography

    International Nuclear Information System (INIS)

    Yoon, Seok Hwan; Lee, Won Hong; Lee, Dae Hyung

    2009-01-01

    Atherosclerotic disease at the origin of the vertebral arteries is one of the risk factors for vertebrobasilar ischemic disease. Assessment and visualization of the origin of the vertebral arteries with color doppler sonography is a non-trivial task. The aim of this study is to increase the visualization rate of the origin of the vertebral arteries with color doppler sonography. Color doppler sonography for the vertebral arteries included carotid arteries was performed to 198 patients. We first examined the vertebral artery in the upper neck in the direction of the subclavian artery to distinguish its origin more easily. If the vertebral artery origin was not visualized in natural position, the examiner pushed the transducer toward a clavicle or pushed the shoulder of patient by the other hand. The technical methods for visualization of the vertebral artery origin were classified into three grades: natural position, pushing the transducer, and pushing the shoulder of patient according to the depth (3.0 cm and shallower, deeper than 3.0 cm) of the origin. The origin of the vertebral arteries could be visualized in 97% on the right and in 92% on the left. The origin of the vertebral arteries could be visualized in 98.6%, 1.4%, and 0.0% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 81.2%, 14.6%, and 4.2% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at deeper than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 85.4%, 10.7%, and 3.9% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the left side. The origin of the vertebral arteries could be visualized in 55.7%, 30.4%, and 13.9% in natural position, pushing the transducer, and pushing the shoulder of

  15. Real-Time Disk Scheduling in a Mixed-Media File System

    NARCIS (Netherlands)

    Bosch, H.G.P.; Mullender, Sape J.

    2000-01-01

    This paper presents our real-time disk scheduler called the L scheduler, which optimizes unscheduled best-effort disk requests by giving priority to best-effort disk requests while meeting real-time request deadlines. Our scheduler tries to execute real-time disk requests as much as possible in the

  16. Real-time centre detection of an OLED structure

    NARCIS (Netherlands)

    Pieters, R.S.; Jonker, P.P.; Nijmeijer, H.

    2009-01-01

    The research presented in this paper focuses on real-time image processing for visual servoing, i.e. the positioning of a x-y table by using a camera only instead of encoders. A camera image stream plus real-time image processing determines the position in the next iteration of the table controller.

  17. Real-Time Center Detection of an OLED Structure

    NARCIS (Netherlands)

    Pieters, R.S.; Jonker, P.P.; Nijmeijer, H.; Blanc-Talon, J.; Philips, W.; Popescu, D.; Scheunders, P.

    2009-01-01

    The research presented in this paper focuses on real-time image processing for visual servoing, i.e. the positioning of a x-y table by using a camera only instead of encoders. A camera image stream plus real-time image processing determines the position in the next iteration of the table controller.

  18. Fused aromatic thienopyrazines: structure, properties and function

    KAUST Repository

    Mondal, Rajib; Ko, Sangwon; Bao, Zhenan

    2010-01-01

    Recent development of a fused aromatic thieno[3.4-b]pyrazine system and their application in optoelectronic devices are reviewed. Introduction of a fused aromatic unit followed by side chain engineering, dramatically enhanced the charge carrier

  19. X-real-time executive (X-RTE) an ultra-high reliable real-time executive for safety critical systems

    International Nuclear Information System (INIS)

    Suresh Babu, R.M.

    1995-01-01

    With growing number of application of computers in safety critical systems of nuclear plants there has been a need to assure high quality and reliability of the software used in these systems. One way to assure software quality is to use qualified software components. Since the safety systems and control systems are real-time systems there is a need for a real-time supervisory software to guarantee temporal response of the system. This report describes one such software package, called X-Real-Time Executive (or X-RTE), which was developed in Reactor Control Division, BARC. The report describes all the capabilities and unique features of X-RTE and compares it with a commercially available operating system. The features of X-RTE include pre-emptive scheduling, process synchronization, inter-process communication, multi-processor support, temporal support, debug facility, high portability, high reliability, high quality, and extensive documentation. Examples have been used very liberally to illustrate the underlying concepts. Besides, the report provides a brief description about the methods used, during the software development, to assure high quality and reliability of X-RTE. (author). refs., 11 figs., tabs

  20. Real time freeway incident detection.

    Science.gov (United States)

    2014-04-01

    The US Department of Transportation (US-DOT) estimates that over half of all congestion : events are caused by highway incidents rather than by rush-hour traffic in big cities. Real-time : incident detection on freeways is an important part of any mo...