WorldWideScience

Sample records for real-time contrast-enhanced ultrasonography

  1. Real-time 3-dimensional contrast-enhanced ultrasound in detecting hemorrhage of blunt renal trauma.

    Science.gov (United States)

    Xu, Rui-Xue; Li, Ye-Kuo; Li, Ting; Wang, Sha-Sha; Yuan, Gui-Zhong; Zhou, Qun-Fang; Zheng, Hai-Rong; Yan, Fei

    2013-10-01

    The objective of this study is to evaluate the diagnostic value of real-time 3-dimensional contrast-enhanced ultrasound in the hemorrhage of blunt renal trauma. Eighteen healthy New Zealand white rabbits were randomly divided into 3 groups. Blunt renal trauma was performed on each group by using minitype striker. Ultrasonography, color Doppler flow imaging, and contrast-enhanced 2-dimensional and real-time 3-dimensional ultrasound were applied before and after the strike. The time to shock and blood pressure were subjected to statistical analysis. Then, a comparative study of ultrasound and pathology was carried out. All the struck kidneys were traumatic. In the ultrasonography, free fluid was found under the renal capsule. In the color Doppler flow imaging, active hemorrhage was not identified. In 2-dimensional contrast-enhanced ultrasound, active hemorrhage of the damaged kidney was characterized. Real-time 3-dimensional contrast-enhanced ultrasound showed a real-time and stereoscopic ongoing bleeding of the injured kidney. The wider the hemorrhage area in 4-dimensional contrast-enhanced ultrasound was, the faster the blood pressure decreased. Real-time 3-dimensional contrast-enhanced ultrasound is a promising noninvasive tool for stereoscopically and vividly detecting ongoing hemorrhage of blunt renal trauma in real time. © 2013.

  2. International guidelines for contrast-enhanced ultrasonography

    DEFF Research Database (Denmark)

    Nolsøe, Christian Pállson; Lorentzen, Torben

    2016-01-01

    The intent of this review is to discuss and comment on common clinical scenarios in which contrast-enhanced ultrasonography (CEUS) may play a decisive role and to illustrate important points with typical cases. With the advent of CEUS, the scope of indications for ultrasonography has been dramati...

  3. Characterisation of focal liver lesions with contrast enhanced ultrasonography

    International Nuclear Information System (INIS)

    Dietrich, Christoph F.

    2004-01-01

    Ultrasound contrast agents (USCA) have improved the detection rate of liver tumours in recent years. Conventional ultrasound has been reported to be relatively unreliable in the characterisation of liver tumours. SonoVue [reg] (Bracco Imaging Spa) has been shown to be particularly advantageous in the differentiation of benign and malignant liver tumours and, therefore, possibly represents a new cost-effective competitive alternative to other liver imaging modalities (e.g. computed tomography and magnetic resonance imaging), thus allowing these important technologies to be available for other indications (e.g. brain, thorax). More detailed and specific liver tumour characterisation is possible in about 80% of liver tumours due to typical vascularity and perfusion patterns. The role of USCA for better characterisation, which is possible through the analysis of flow characteristics in real time, places a particular emphasis on agent use. Contrast enhanced real-time imaging techniques with SonoVue [reg] allow real-time analysis of tumour perfusion in patients with liver lesions. Liver tumours known to be hyperperfused in the arterial phase (e.g. focal nodular hyperplasia, hepatocellular adenoma and carcinoma, and hyperperfused metastases) can be better detected and characterised. Hypoperfused tumours (e.g. liver metastases of the gastrointestinal tract) can be recognised in the portal venous phase as less perfused 'black spots'. In this article we discuss liver tumour characterisation by contrast enhanced ultrasonography

  4. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncica, Ana Maria; Saftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...

  5. Contrast-enhanced endoscopic ultrasonography in digestive diseases.

    Science.gov (United States)

    Hirooka, Yoshiki; Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi

    2012-10-01

    Contrast-enhanced endoscopic ultrasonography (CE-EUS) was introduced in the early 1990s. The concept of the injection of carbon dioxide microbubbles into the hepatic artery as a contrast material (enhanced ultrasonography) led to "endoscopic ultrasonographic angiography". After the arrival of the first-generation contrast agent, high-frequency (12 MHz) EUS brought about the enhancement of EUS images in the diagnosis of pancreatico-biliary diseases, upper gastrointestinal (GI) cancer, and submucosal tumors. The electronic scanning endosonoscope with both radial and linear probes enabled the use of high-end ultrasound machines and depicted the enhancement of both color/power Doppler flow-based imaging and harmonic-based imaging using second-generation contrast agents. Many reports have described the usefulness of the differential diagnosis of pancreatic diseases and other abdominal lesions. Quantitative evaluation of CE-EUS images was an objective method of diagnosis using the time-intensity curve (TIC), but it was limited to the region of interest. Recently developed Inflow Time Mapping™ can be generated from stored clips and used to display the pattern of signal enhancement with time after injection, offering temporal difference of contrast agents and improved tumor characterization. On the other hand, three-dimensional CE-EUS images added new information to the literature, but lacked positional information. Three-dimensional CE-EUS with accurate positional information is awaited. To date, most reports have been related to pancreatic lesions or lymph nodes. Hemodynamic analysis might be of use for diseases in other organs: upper GI cancer diagnosis, submucosal tumors, and biliary disorders, and it might also provide functional information. Studies of CE-EUS in diseases in many other organs will increase in the near future.

  6. Dynamic Contrast-Enhanced Magnetic Resonance Enterography and Dynamic Contrast-Enhanced Ultrasonography in Crohn's Disease

    DEFF Research Database (Denmark)

    Wilkens, Rune; Peters, David A; Nielsen, Agnete Hedemann

    2017-01-01

    Purpose e Cross-sectional imaging methods are important for objective evaluationof small intestinal inflammationinCrohn'sdisease(CD).The primary aim was to compare relative parameters of intestinal perfusion between contrast-enhanced ultrasonography (CEUS) and dynamic contrast-enhanced magnetic...

  7. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncică, Ana Maria; Săftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...... cancers and visualization of the portal venous system and esophageal varices. In addition, contrast agents can be used to differentiate pancreatic lesions. The use of color Doppler further increases the ability to diagnose and differentiate various pancreatic malignancies. The sensitivity of power Doppler...

  8. Microwave ablation assisted by a real-time virtual navigation system for hepatocellular carcinoma undetectable by conventional ultrasonography

    International Nuclear Information System (INIS)

    Liu Fangyi; Yu Xiaoling; Liang Ping; Cheng Zhigang; Han Zhiyu; Dong Baowei; Zhang Xiaohong

    2012-01-01

    Objectives: To evaluate the efficiency and feasibility of microwave (MW) ablation assisted by a real-time virtual navigation system for hepatocellular carcinoma (HCC) undetectable by conventional ultrasonography. Methods: 18 patients with 18 HCC nodules (undetectable on conventional US but detectable by intravenous contrast-enhanced CT or MRI) were enrolled in this study. Before MW ablation, US images and MRI or CT images were synchronized using the internal markers at the best timing of the inspiration. Thereafter, MW ablation was performed under real-time virtual navigation system guidance. Therapeutic efficacy was assessed by the result of contrast-enhanced imagings after the treatment. Results: The target HCC nodules could be detected with fusion images in all patients. The time required for image fusion was 8–30 min (mean, 13.3 ± 5.7 min). 17 nodules were successfully ablated according to the contrast enhanced imagings 1 month after ablation. The technique effectiveness rate was 94.44% (17/18). The follow-up time was 3–12 months (median, 6 months) in our study. No severe complications occurred. No local recurrence was observed in any patients. Conclusions: MW ablation assisted by a real-time virtual navigation system is a feasible and efficient treatment of patients with HCC undetectable by conventional ultrasonography.

  9. The role of contrast-enhanced ultrasonography in image-guided liver ablations

    International Nuclear Information System (INIS)

    Pescatori, Lorenzo Carlo; Sconfienza, Luca Maria; Mauri, Giovanni

    2016-01-01

    We read with great interest the paper by Kim et al. entitled “Local ablation therapy with contrast enhanced ultrasonography for hepatocellular carcinoma: a practical review,” recently published in Ultrasonography. We think that contrast-enhanced ultrasonography (CEUS), together with the development of reliable navigation systems, is likely to represent one of the most important advances in image-guided ablations in recent years. Thus, we offer some considerations on the topic

  10. Contrast-enhanced ultrasonography depicts small tumor vessels for the evaluation of pancreatic tumors

    International Nuclear Information System (INIS)

    Okamoto, Yuko; Kawamoto, Hirofumi; Takaki, Akinobu; Ishida, Etsuji; Ogawa, Tsuneyoshi; Kuwaki, Kenji; Kobayashi, Yoshiyuki; Sakaguchi, Kohsaku; Shiratori, Yasushi

    2007-01-01

    Objective: The aim of this study is to evaluate the efficacy of contrast-enhanced ultrasonography for the diagnosis of pancreatic tumors. Materials and methods: Contrast-enhanced ultrasonography with Levovist was performed on 62 consecutive patients (53 with pancreatic cancer, 4 with islet cell tumor, 3 with inflammatory pancreatic tumor, and 2 with metastatic tumor). The vascular and perfusion image phases of the tumors were evaluated and compared with the findings of contrast-enhanced computed tomography. Results: Contrast-enhanced ultrasonography showed tumor vessels around and/or in the tumor at the vascular image phase in 79% of pancreatic cancer patients (42/53). At the perfusion image phase, 96% of pancreatic cancers (51/53) were classified as hypo-enhancement type. However, tiny spotty or irregular heterogeneous enhanced lesions were found in 84% of hypo-enhanced pancreatic cancer patients (43/51). The presence of small vessels at the vascular image phase was closely correlated with the presence of these intratumor regional enhanced lesions at the perfusion image phase (κ coefficient = 0.42). The sensitivity of contrast-enhanced ultrasonography (100%) for pancreatic cancer was superior to that of contrast-enhanced computed tomography (91%), but no significant difference was observed between the two (McNemar test: p = 0.063). Conclusion: Contrast-enhanced ultrasonography with Levovist successfully visualizes fine vessels and enhancement in pancreatic tumors, and is useful for evaluating pancreatic tumors

  11. Can contrast-enhanced ultrasonography improve Zone III REBOA placement for prehospital care?

    Science.gov (United States)

    Chaudery, Muzzafer; Clark, James; Morrison, Jonathan J; Wilson, Mark H; Bew, Duncan; Darzi, Ara

    2016-01-01

    Torso hemorrhage is the primary cause of potentially preventable mortality in trauma. Resuscitative endovascular balloon occlusion of the aorta (REBOA) has been advocated as an adjunct to bridge patients to definitive hemorrhage control. The primary aim of this study was to assess whether contrast-enhanced ultrasonography can improve the accuracy of REBOA placement in the infrarenal aorta (Zone III). A fluoroscopy-free "enhanced" Zone III REBOA technique was developed using a porcine cadaver model. A "standard" over-the-wire Seldinger technique was used, which was enhanced with the addition of a microbubble contrast medium to inflate the balloon, observed with ultrasonography. Following this, attending- and resident-level physicians were randomized into two groups. They were taught either the enhanced with ultrasonography guidance (Group A) or the standard measuring length of catheter insertion (Group B) technique as part of a human cadaver trauma skills course. Outcomes assessed included time (seconds) from insertion to inflation, accuracy, and missed targets. All results were benchmarked against three endovascular experts. There were 20 participants who performed REBOA with Group A (51 [31]) being significantly faster than Group B (90 [63]) (p = 0.003) and more accurate (p = 0.023) with no missed targets. Group B had five missed targets, the most common error being inflation within Zone II. For Zone III REBOA, contrast-enhanced ultrasonography technique is faster and more accurate than the standard technique. This may have value in time-critical and austere environments. Clinical studies are now required to evaluate this approach further.

  12. Local ablation therapy with contrast-enhanced ultrasonography for hepatocellular carcinoma: a practical review

    Directory of Open Access Journals (Sweden)

    Tae Kyoung Kim

    2015-10-01

    Full Text Available A successful program for local ablation therapy for hepatocellular carcinoma (HCC requires extensive imaging support for diagnosis and localization of HCC, imaging guidance for the ablation procedures, and post-treatment monitoring. Contrast-enhanced ultrasonography (CEUS has several advantages over computed tomography/magnetic resonance imaging (CT/MRI, including real-time imaging capability, sensitive detection of arterial-phase hypervascularity and washout, no renal excretion, no ionizing radiation, repeatability, excellent patient compliance, and relatively low cost. CEUS is useful for image guidance for isoechoic lesions. While contrast-enhanced CT/MRI is the standard method for the diagnosis of HCC and post-ablation monitoring, CEUS is useful when CT/MRI findings are indeterminate or CT/MRI is contraindicated. This article provides a practical review of the role of CEUS in imaging algorithms for pre- and post-ablation therapy for HCC.

  13. Real time ultrasonography in obstructive jaundice

    International Nuclear Information System (INIS)

    Cho, Kyung Sik; Kim, Ho Kyun; Sung, Nak Kwan; Kim, Soon Yong

    1982-01-01

    Ultrasonography is a predominantly accurate, relatively simple unique diagnostic method of obstructive jaundice. The ultrasonographic findings of obstructive jaundice are dilated intra- and extrahepatic duct with intraluminal hyper reflective echo or mass in and/ or around the bile duct. The superiority of high resolution real time ultrasonography for the diagnosis of obstructive jaundice is bases on the easy detectability of extra- and intrahepatic bile ducts by its multiple sectional images in a short time, the flexibility of probe and small crystal size. Author evaluated real time sonographic findings 46 obstructive jaundice patients confirmed by surgery or radiographical examinations. The results were: 1. Diameter of extrahepatic duct in obstructive jaundice were varied from normal to 4.0 Cm, mostly 8 to 10 mm in diameter (26%). Degree of dilatation of biliary duct appeared more prominent in cancer patients than other causes of obstruction. 2. The site of obstruction was detected in 85% (39/46) and its common site was common bile duct in 63% (29/46). 3. The diagnostic accuracy of choledocholithiasis and cancer was 82% (22/27) and 44% (4/9), respectively. Diagnostic accuracy of the real time ultrasonography in obstructive jaundice was over all 75% (34/46)

  14. Contrast-enhanced power Doppler ultrasonography of the metacarpophalangeal joints in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Szkudlarek, Marcin; Court-Payen, Michel; Strandberg, Charlotte

    2003-01-01

    The aim of this study was to examine, with dynamic contrast-enhanced MRI as the reference, if contrast-enhanced power Doppler ultrasonography (CE PDUS) of rheumatoid arthritis (RA) metacarpophalangeal (MCP) joints provides additional information for evaluation of synovial inflammation compared...... with PDUS. One MCP joint in each of 15 RA patients and 3 healthy control persons were examined with PDUS before and after intravenous bolus Levovist contrast injection. Corresponding rates of early synovial enhancement (RESE), previously shown to be closely related to histopathological synovitis, were...... calculated from dynamic contrast-enhanced MR images obtained the same day. Prior to ultrasonography, the joint was evaluated clinically. Levovist increased the flow signal in 7 of 9 joints with pre-contrast flow-signal and in 0 of 9 without pre-contrast signal. No healthy controls showed CE PDUS signal...

  15. Contrast-Enhanced Harmonic Ultrasonography for the Assessment of Prostate Cancer Aggressiveness: a Preliminary Study

    International Nuclear Information System (INIS)

    Zhu, Yunkai; Chen, Yaqing; Jiang, Jun; Wang, Ren; Zhou, Yongchang; Zhang, Huizhen

    2010-01-01

    To determine whether contrast-enhanced harmonic ultrasonography can be used to predict the aggressiveness of prostate cancer. Contrast-enhanced harmonic ultrasonography was performed in 103 patients suspected of prostate cancer before biopsy. Time intensity curves were reconstructed for systematic biopsy sites and sonographic abnormalities. The characteristics of the curves were described using hemodynamic indices including arrival time (AT), time-to-peak (TTP), and peak intensity (PI). The differences of hemodynamic indices between high-grade and low-grade cancer were analyzed and the correlations between the hemodynamic indices and biopsy Gleason score were studied. Prostate cancer was detected in 41 of 103 patients and there were significant differences in the hemodynamic indices between the biopsy sites of the non-malignant patients and prostate cancer lesions (p < 0.05). The prostate biopsies revealed 154 prostate cancer lesions, including 31 low-grade lesions and 123 high-grade lesions. The hemodynamic indices AT and TTP of highgrade tumors were significantly shorter than those of low-grade tumors (p = 0.001, 0.002). In addition, high-grade peripheral zone (PZ) tumors had higher PI than low-grade PZ tumors (p = 0.009). The PZ prostate cancer Gleason score correlated with PI, AT and TTP, with Spearman correlation coefficients of 0.223, -0.335, and -0.351, respectively (p = 0.013, < 0.001 and < 0.001). Contrast-enhanced ultrasound measurements of hemodynamic indices correlate with the prostate cancer Gleason score

  16. Analysis of contrast-enhanced ultrasonography using time-intensity curves in prostatic hyperplasia and prostate cancer

    International Nuclear Information System (INIS)

    Fang Junchu; Chen Ming; Sun Huifen

    2008-01-01

    Objective: To study the characters of time-intensity curve of contrast-enhanced ultrasonography in benign prostate hyperplasia (BPH) and prostate cancer. Methods: 2.4 ml Sono Vue were injected as a bolus in 40 patients, 23 patients with BPH and 17 with prostate cancer. High perfusion area in both inner and outer gland were measured with time-intensity curves. Results: It was proved by the time-intensity curves that, in BPH cases, the outer prostate gland presented with mild enhancedment and slow wash-off, while the inner gland presented with moderate enhancedment and fast wash-off. Otherwise, both the inner and outer gland in prostate cancer cases presented with high-intensitive enhancedment and slow wash-off. There was marked difference statistical significance on the up slop, average intensity and area under the time-intensity curves in 90 s and 150 s between the cases of BPH and prostate cancer (P<0.05, P<0.01). Conclusion: Quantitative analysis of high perfusion area in both inner and outer glands is helpful for diagnosing BPH and prostate cancer. (authors)

  17. Contrast-Enhanced Ultrasonography in Crohn's Disease Diagnostics.

    Science.gov (United States)

    Białecki, Marcin; Białecka, Agnieszka; Laskowska, Katarzyna; Liebert, Ariel; Kłopocka, Maria; Serafin, Zbigniew

    2015-06-01

    The chronic nature of Crohn's disease (CD) implicates necessity of multiple control assessments throughout patient's life. It is accepted that in patients with CD requiring disease monitoring, magnetic resonance enterography (MRE) and computed tomography enterography (CTE) are--apart from endoscopy--imaging studies of first choice. In practice, diagnostic imaging of patients with CD is troublesome, since MRE is an expensive and complicated study, and CTE exposes patients to high doses of ionizing radiation. Therefore, there is a need for new, both non-invasive and effective, methods of imaging in CD. Contrast-Enhanced Ultrasonography (CEUS) is a relatively new method using gas-filled microbubbles serving as contrast agent. It allows for detailed assessment of blood perfusion within intestine wall and peri-intestinal tissues, which enables detection and monitoring of inflammation and its qualitative assessment. The purpose of this paper is to describe CEUS examination technique and its clinical applications in patients with Crohn's disease.

  18. Contrast-enhanced ultrasonography for the determination of Crohn's disease activity - preliminary experience.

    Science.gov (United States)

    Białecki, Marcin; Białecka, Agnieszka; Laskowska, Katarzyna; Kłopocka, Maria; Liebert, Ariel; Lemanowicz, Adam; Serafin, Zbigniew

    2014-01-01

    Contrast-enhanced ultrasound (CEUS) is a recent non-invasive modality, which may partially replace currently used techniques (endoscopy, CT enterography and MR enterography) in the diagnostics and assessment of Crohn's disease (CD). The aim of the study was to analyze early experience in the use of CEUS for the measurement of activity and staging of CD. Eleven patients previously diagnosed with CD were included in the study. They underwent contrast-enhanced ultrasonography (SonoVue, Bracco), low-dose CT enterography (LDCTE), assessment of laboratory markers of inflammation and clinical CD activity index (CDAI). Contrast enhancement was evaluated using a semi-quantitative method and a quantitative method that included measurement of peak enhancement (PE), enhancement curve rise time (RT) and wash-in-rate (WiR). Ileal wall thickening was observed in all patients. Semi-quantitative method was used to observe CD activity in CEUS in 10 cases that perfectly matched LDCTE findings. There was a moderate positive correlation between PE and CDAI (r=0.65, p<0.001). There was no significant relationship between perfusion parameters and laboratory markers of inflammation. CEUS is a promising modality for non-invasive assessment of pathologic ileal vascularization in the course of Crohn's disease. Intensity of enhancement in CEUS reflects activity of the disease detected in LDCTE and correlates with CDAI.

  19. Evaluation of residual hepatocellular carcinoma after transcatheter arterial chemoembolization: Comparison between contrast-enhanced helical CT and contrast-enhanced power doppler ultrasonography

    International Nuclear Information System (INIS)

    Kim, Seung Hoon; Lim, Hyo Keun; Lee, Won Jae

    2001-01-01

    To evaluate the effectiveness of contrast-enhanced helical CT and contrast-enhanced power doppler ultrasonography (PDUS) in assessing the therapeutic effect of transcatheter arterial chemoembolization (TACE) in hepatocellular carcinomas (HCCs). The follow-up contrast-enhanced helical CT and contrast-enhanced PDUS were performed for twenty-nine nodular HCCs from twelve patients previously treated with TACE. We defined the residual HCCs as intratumoral enhancing area on contrast-enhanced helical CT and color signal on contrast-enhanced PDUS. The interval between two examinations was less than 2 weeks (mean, 9 days). Two radiologists evaluated two examinations by consensus, and the results of these two examination were compared with the findings of other examinations including CT, angiography, and/or pathology to calculate the sensitivity, specificity and accuracy of two examinations. Of the 29 HCCs, 20 had residual HCCs whereas no residual HCCs in 9 HCCs on pathologic examination and/or follow-up radiologic study. The sensitivity, sensitivity and accuracy of contrast-enhanced helical CT were 65 (13/20), 89 (8/9), and 72% (21/29) while those of contrast-enhanced PDUS were 100 (20/20), 89 (8/9) and 97% (28/29), respectively. A microbubble contrast-enhanced PDUS was more effective in the detection of residual tumor in HCCs following TACE than contrast-enhanced helical CT.

  20. Dynamics of contrast enhancement in MR imaging and power Doppler ultrasonography of solid breast lesions

    International Nuclear Information System (INIS)

    Reinikainen, H.; Paeaekkoe, E.; Suramo, I.; Paeivaensalo, M.; Rissanen, T.

    2002-01-01

    Purpose: To evaluate the dynamics of contrast enhancement in solid breast lesions at contrast-enhanced MR imaging and power Doppler ultrasonography (US) and to compare the methods to histology and to each other. Material and Methods: Forty breast lesions were prospectively examined with dynamic MR and power Doppler US. Time-signal intensity curves of enhancement were obtained for both methods. The shape of the curve was analyzed to be benign, indeterminate or malignant. The curves were also analyzed quantitatively by calculating the slope of the curve and the area under the curve (both methods), relative enhancement (MR), and time to peak (US). The lesions were divided into malignant lesions, fibroadenomas, and other benign lesions. The results were compared to histology. Results: In the subjective analysis of the MR curve in differentiating between benign and malignant lesions the accuracy was 90%. The MR curve also enabled differentiation between fibroadenomas and malignancies. The accuracy of the US curve was 38%. Quantitatively, statistically significant differences were found using all the MR variables, except between malignancies and fibroadenomas. Using the US variables, no significant difference was found between the groups. Conclusion: The dynamics of contrast-enhanced MR were reliable in the differential diagnosis of solid breast lesions, but contrast-enhanced power Doppler US was of limited value

  1. Radiofrequency ablation of liver cancer: early evaluation of therapeutic response with contrast-enhanced ultrasonography

    International Nuclear Information System (INIS)

    Choi, Dong Gil; Lim, Hyo K.; Lee, Won Jae; Kim, Seung Hoon; Kim, Min Ju; Kim, Seung Kwon; Jang, Kyung Mi; Lee, Ji Yeon; Lim, Jae Hoon

    2004-01-01

    The early assessment of the therapeutic response after percutaneous radiofrequency (RF) ablation is important, in order to correctly decide whether further treatment is necessary. The residual unablated tumor is usually depicted on contrast-enhanced multiphase helical computed tomography (CT) as a focal enhancing structure during the arterial and portal venous phases. Contrast-enhanced color Doppler and power Doppler ultrasonography (US) have also been used to detect residual tumors. Contrast-enhanced gray-scale US, using a harmonic technology which has recently been introduced, allows for the detection of residual tumors after ablation, without any of the blooming or motion artifacts usually seen on contrast-enhanced color or power Doppler US. Based on our experience and reports in the literature, we consider that contrast-enhanced gray-scale harmonic US constitutes a reliable alternative to contrast-enhanced multiphase CT for the early evaluation of the therapeutic response to RF ablation for liver cancer. This technique was also useful in targeting any residual unablated tumors encountered during additional ablation

  2. Quantitative Assessment of Hepatic Fibrosis by Contrast-enhanced Ultrasonography

    Institute of Scientific and Technical Information of China (English)

    Ming-bo Zhang; En-ze Qu; Ji-Bin Liu; Jin-rui Wang

    2011-01-01

    Objective To explore the contrast-enhanced ultrasonographic features for quantitative assessment of hepatic fibrosis.Methods 86 patients with chronic viral hepatitis B were enrolled in this study from March 2007 to August 2009.The patients were classified into 5 groups (S0-S4) according to fibrosis stage evaluated with ultrasound guided liver biopsy.New contrast-enhanced ultrasonography (CEUS) features including area under the time-intensity curve (TIC) of portal venous phase/hepatic arterial phase (Qp/Qa) and intensity of portal venons phase/hepatic arterial phase (Ip/Ia) were used to detect the blood supply ratio (portal vein/hepatic artery) in each group.Arrival time of portal vein trunk (Tp) and decreasing rate of TIC (β) were also analyzed.Results Qp/Qa and Ip/Ia decreased from So to S4,while Tp and β increased These 4 features were significantly correlated with the degree of fibrosis (P<0.001) and were significantly different among the five groups (P<0.001).Sensitivity and specificity of Ip/Ia were 80% and 86% for groups ≥S1,75% and 86% for groups ≥ S2,71% and 84% for groups ≥ S3,and 76% and 80% for group S4,respectively.Sensitivity and specificity of Qp/Qa were 70% and 88% for groups ≥ S1,80% and 76% for groups ≥ S2,74% and 70% for groups ≥ S3,and 81% and 95% for group S4,respectively.Conclusion Ip/Ia and Qp/Qa could be adopted as reliable,non-invasive features for quantitative assessment of hepatic fibrosis.

  3. Contrast-Enhanced Endoscopic Ultrasonography for Pancreatic Tumors

    Directory of Open Access Journals (Sweden)

    Yasunobu Yamashita

    2015-01-01

    Full Text Available Objectives. To investigate the usefulness of contrast-enhanced endoscopic ultrasonography (CE-EUS for histological differentiation of pancreatic tumors. Methods. CE-EUS was performed for consecutive patients having a pancreatic solid lesion, and tumors were classified into three vascular patterns (hypervascular, isovascular, and hypovascular at two time phases (early-phase and late-phase. Correlation between vascular patterns and histopathology of resected pancreatic cancer (PC tissues was ascertained. Results. The final diagnoses of 147 examined tumors were PC (n=109, inflammatory mass (n=11, autoimmune pancreatitis (n=9, neuroendocrine tumor (n=8, and others (n=10. In late-phase images, 104 of 109 PCs had the hypovascular pattern, for a diagnostic sensitivity and specificity of 94% and 71%, respectively. Of 28 resected PCs, 10 had isovascular, and 18 hypovascular, patterns on the early-phase image. Early-phase isovascular PCs were more likely to be differentiated than were early-phase hypovascular PCs (6 well and 4 moderately differentiated versus 3 well, 14 moderately, and 1 poorly differentiated, P=0.028. Immunostaining revealed that hypovascular areas of early-phase images reflected heterogeneous tumor cells with fibrous tissue, necrosis, and few vessels. Conclusion. CE-EUS could be useful for distinguishing PC from other solid pancreatic lesions and for histological differentiation of PCs.

  4. International guidelines for contrast-enhanced ultrasonography: Ultrasound imaging in the new millennium

    International Nuclear Information System (INIS)

    Nolsoe, Christian Pallson; Lorentzen, Torben

    2016-01-01

    The intent of this review is to discuss and comment on common clinical scenarios in which contrast-enhanced ultrasonography (CEUS) may play a decisive role and to illustrate important points with typical cases. With the advent of CEUS, the scope of indications for ultrasonography has been dramatically extended, and now includes functional imaging and tissue characterization, which in many cases enable tumor diagnosis without a biopsy. It is virtually impossible to imagine the practice of modern medicine as we know it in high-income countries without the use of imaging, and yet, an estimated two thirds of the global population may receive no such care. Ultrasound imaging with CEUS has the potential to correct this inequity

  5. International guidelines for contrast-enhanced ultrasonography: Ultrasound imaging in the new millennium

    Energy Technology Data Exchange (ETDEWEB)

    Nolsoe, Christian Pallson; Lorentzen, Torben [Ultrasound Section, Dept. of Gastric Surgery, Herlev Hospital, University of Copenhagen, Herlev (Denmark)

    2016-03-15

    The intent of this review is to discuss and comment on common clinical scenarios in which contrast-enhanced ultrasonography (CEUS) may play a decisive role and to illustrate important points with typical cases. With the advent of CEUS, the scope of indications for ultrasonography has been dramatically extended, and now includes functional imaging and tissue characterization, which in many cases enable tumor diagnosis without a biopsy. It is virtually impossible to imagine the practice of modern medicine as we know it in high-income countries without the use of imaging, and yet, an estimated two thirds of the global population may receive no such care. Ultrasound imaging with CEUS has the potential to correct this inequity.

  6. [Diagnostic utility of endoscopic ultrasonography elastography and contrast-enhanced harmonic endoscopic ultrasonography in a patient with type 2 autoimmune pancreatitis].

    Science.gov (United States)

    Yokode, Masataka; Shiomi, Hideyuki; Itai, Ryosuke; Mikami, Sakae; Yamashita, Yukimasa; Nakano, Ryota; Ezaki, Takeshi; Masuda, Atsuhiro; Zen, Yoh

    2018-01-01

    A referring hospital diagnosed a 57-year-old man with a pancreatic head mass. The initial endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) was inconclusive because of the small sample size. Endoscopic ultrasonography elastography (EUS-EG) and contrast-enhanced harmonic endoscopic ultrasonography (CE-EUS), conducted at our institute, raised the possibility of mass-forming pancreatitis or autoimmune pancreatitis (AIP). A repeat EUS-FNA revealed inflammatory changes, including a neutrophilic duct injury suggestive of type 2 AIP. The pancreatic lesion responded well to the steroid therapy. The present case suggests that EUS-EG and CE-EUS may be useful for diagnostic exclusion of pancreatic cancers, and the combined use of EUS-EG and CE-EUS, with EUS-FNA, may help characterize inflammatory pancreatic lesions.

  7. Contrast-enhanced ultrasonography of hepatocellular carcinoma: Correlation between quantitative parameters and arteries in neoangiogenesis or sinusoidal capillarization

    International Nuclear Information System (INIS)

    Pei Xiaoqing; Liu Longzhong; Zheng Wei; Cai Muyan; Han Feng; He Jiehua; Li Anhua; Chen Minshan

    2012-01-01

    Objective: The quantitative parameters in contrast-enhanced ultrasonography-time–intensity curve of hepatocellular carcinoma (HCC) were studied to explore their potential importance in monitoring the effects of anti-angiogenic therapy for HCC. Methods: 115 HCC patients were studied with contrast-enhanced ultrasonography-time–intensity curve (CEUS-TIC) and with immunohistochemical analysis of tissue sections. The CEUS images were analyzed off-line to obtained quantitative parameters including maximum of intensity (IMAX), rise time (RT), time to peak (TTP), mean transit time (mTT), rise slope (RS), and washout time (WT). Monoclonal antibodies specific for smooth muscle actin and anti-CD34 were used to observe unpaired arteries (UAs) and microvessel area (MVA) of sinusoidal capillarization, respectively. The UAs and MVA of 82 HCC cases were successfully stained. Results: The number of UAs had moderate correlation with RT (r = −0.446), TTP (r = −0.432), and RS (r = 0.431) (P < 0.05), and it had mild correlation with IMAX (r = 0.303) and WT (r = 0.285) (P < 0.05). MVA of sinusoidal capillarization had no correlation with perfusion parameters. Conclusion: Quantitative CEUS-TIC parameters reflecting hemodynamics of tumors are correlated with UAs, but not with MVA, and they might be used to monitor the effects of anti-angiogenic therapy on HCC.

  8. Evaluation of Hemodynamics in Focal Steatosis and Focal Spared Lesion of the Liver Using Contrast-Enhanced Ultrasonography with Sonazoid

    International Nuclear Information System (INIS)

    Shiozawa, K.; Watanabe, M.; Ikehara, T.; Kogame, M.; Shinohara, M.; Shinohara, M.; Ishii, K.; Igarashi, Y.; Sumino, Y.; Shiozawa, K.; Makino, H.

    2014-01-01

    We aim to investigate the hemodynamics in focal steatosis and focal spared lesion of the liver using contrast-enhanced ultrasonography (CEUS) with Sonazoid. The subjects were 47 patients with focal steatosis and focal spared lesion. We evaluated enhancement patterns (hyper enhancement, iso enhancement, and hypo enhancement) in the vascular phase and the presence or absence of a hypoechoic area in the post vascular phase for these lesions using CEUS. Of the 24 patients with focal steatosis, the enhancement pattern was iso enhancement in 19 and hypo enhancement in 5. Hypoechoic areas were noted in the post vascular phase in 3 patients. Of the 23 patients with focal spared lesions, the enhancement pattern was iso enhancement in 18 and hyper enhancement in 5. No hypoechoic areas were noted in the post vascular phase in any patient. The hemodynamics in focal steatosis and focal spared lesions in non diffuse fatty liver can be observed using low-invasive procedures in real-time by CEUS. It was suggested that differences in the dynamics of enhancement in the vascular phase of CEUS were influenced by the fat deposits in the target lesion, the surrounding liver parenchyma, and the third inflow.

  9. Imaging of the acute scrotum: is there a place for contrast-enhanced ultrasonography?

    Directory of Open Access Journals (Sweden)

    H. Moschouris

    2009-12-01

    Full Text Available Purpose: To present and evaluate the findings of contrast-enhanced ultrasonography (CEUS in typical cases of acute painful scrotum. Materials and methods: Nineteen patients aged from 19 to 61 years old were included in the study. All patients underwent grey-scale and color Doppler ultrasonography (US of the scrotum, followed by imaging after i.v. administration of 2.4 mL of a second generation ultrasound contrast agent (microbubbles of sulphur hexafluoride. A dedicated, contrast-sensitive technique was used (Contrast Tissue Imaging - CnTI. The diagnosis was confirmed surgically in 6 cases while in the remaining 8 cases it was based on the combination of clinical, imaging and laboratory findings. Results: The final diagnosis was testicular torsion (n = 4, epididymitis (n = 2, one of the cases complicated by abscess, testicular abscess (n = 1, scrotal abscess (n = 1, testicular trauma of varying severity (n = 6. Five out of 19 cases were true negatives: neither clinical examination nor laboratory tests revealed any pathology. CEUS showed complete lack of enhancement in all cases of torsion, permitting a rapid and definitive diagnosis. In the cases of infection complicated by abscesses, CEUS delineated the lesions much better than the combination of B-mode/Color Doppler US. The severely traumatized testicles showed minimal, inhomogeneous or patchy enhancement, while cases of minor trauma showed no significant enhancement defects. Hematomas were presented as non-enhancing lesions. Conclusion: Generally, there was no advantage over Doppler US as has been previously shown. However, CEUS can be used supplementary to traditional Doppler US in the investigation of blunt testicular trauma especially when there is uncertainty in diagnosis after appropriate clinical and radiographic evaluations occurs. Further studies are required to clearly define the indications of this method.

  10. The inter-observer agreement in the assessment of carotid plaque neovascularization by contrast-enhanced ultrasonography: The impact of plaque thickness.

    Science.gov (United States)

    Chen, Jian; Zhang, Yan-Ming; Song, Ze-Zhou; Fu, Yan-Fei; Geng, Yu

    2018-04-10

    The interobserver agreement in the assessment of the grade of carotid plaque neovascularization by contrast-enhanced ultrasonography is poorly established. We examined 140 carotid plaques in 66 patients (all patients had bilateral plaques, and 8 patients had 2 plaques on one side). We performed conventional and contrast-enhanced ultrasonography to analyze the presence of carotid plaque neovascularization, which was graded by two independent observers whose interobserver agreement (κ) was evaluated according to the thickness of carotid plaque. For all carotid plaques, the mean κ was 0.689 (95% confidence interval 0.604-0.774). It was 0.689 (0.569-0.808), 0.637 (0.487-0.787), and 0.740 (0.585-0.896), respectively for carotid plaques with maximal thickness 3 mm. The interobserver agreement for assessing carotid plaque neovascularization by using contrast-enhanced ultrasonography is substantial and acceptable for research purposes, regardless of the maximal thickness of the plaque. © 2018 Wiley Periodicals, Inc.

  11. Contrast-enhanced ultrasonography for the determination of Crohn’s disease activity – preliminary experience

    Science.gov (United States)

    Białecki, Marcin; Białecka, Agnieszka; Laskowska, Katarzyna; Kłopocka, Maria; Liebert, Ariel; Lemanowicz, Adam; Serafin, Zbigniew

    2014-01-01

    Summary Background Contrast-enhanced ultrasound (CEUS) is a recent non-invasive modality, which may partially replace currently used techniques (endoscopy, CT enterography and MR enterography) in the diagnostics and assessment of Crohn’s disease (CD). The aim of the study was to analyze early experience in the use of CEUS for the measurement of activity and staging of CD. Material/Methods Eleven patients previously diagnosed with CD were included in the study. They underwent contrast-enhanced ultrasonography (SonoVue, Bracco), low-dose CT enterography (LDCTE), assessment of laboratory markers of inflammation and clinical CD activity index (CDAI). Contrast enhancement was evaluated using a semi-quantitative method and a quantitative method that included measurement of peak enhancement (PE), enhancement curve rise time (RT) and wash-in-rate (WiR). Results Ileal wall thickening was observed in all patients. Semi-quantitative method was used to observe CD activity in CEUS in 10 cases that perfectly matched LDCTE findings. There was a moderate positive correlation between PE and CDAI (r=0.65, p<0.001). There was no significant relationship between perfusion parameters and laboratory markers of inflammation. Conclusions CEUS is a promising modality for non-invasive assessment of pathologic ileal vascularization in the course of Crohn’s disease. Intensity of enhancement in CEUS reflects activity of the disease detected in LDCTE and correlates with CDAI. PMID:24723988

  12. Contrast-enhanced ultrasonography for the determination of Crohn’s disease activity – preliminary experience

    International Nuclear Information System (INIS)

    Białecki, Marcin; Białecka, Agnieszka; Laskowska, Katarzyna; Kłopocka, Maria; Liebert, Ariel; Lemanowicz, Adam; Serafin, Zbigniew

    2014-01-01

    Contrast-enhanced ultrasound (CEUS) is a recent non-invasive modality, which may partially replace currently used techniques (endoscopy, CT enterography and MR enterography) in the diagnostics and assessment of Crohn’s disease (CD). The aim of the study was to analyze early experience in the use of CEUS for the measurement of activity and staging of CD. Eleven patients previously diagnosed with CD were included in the study. They underwent contrast-enhanced ultrasonography (SonoVue, Bracco), low-dose CT enterography (LDCTE), assessment of laboratory markers of inflammation and clinical CD activity index (CDAI). Contrast enhancement was evaluated using a semi-quantitative method and a quantitative method that included measurement of peak enhancement (PE), enhancement curve rise time (RT) and wash-in-rate (WiR). Ileal wall thickening was observed in all patients. Semi-quantitative method was used to observe CD activity in CEUS in 10 cases that perfectly matched LDCTE findings. There was a moderate positive correlation between PE and CDAI (r=0.65, p<0.001). There was no significant relationship between perfusion parameters and laboratory markers of inflammation. CEUS is a promising modality for non-invasive assessment of pathologic ileal vascularization in the course of Crohn’s disease. Intensity of enhancement in CEUS reflects activity of the disease detected in LDCTE and correlates with CDAI

  13. Diagnostic value of contrast-enhanced ultrasonography in the characterization of ovarian tumors().

    Science.gov (United States)

    Sconfienza, L M; Perrone, N; Delnevo, A; Lacelli, F; Murolo, C; Gandolfo, N; Serafini, G

    2010-03-01

    Vascularity influences the characteristics of gynecologic tumors observed with direct imaging techniques that reveal the macrovascular component of these lesions (color and power Doppler) and with indirect imaging involving the administration of contrast agents to examine the microcirculation and interstitial perfusion (contrast-enhanced computed tomography [CT] and magnetic resonance [MR] imaging). The purpose of this study was to determine whether contrast-enhanced ultrasonography (CEUS) of ovarian lesions provides useful information that cannot be obtained with conventional US. We used CEUS to assess 72 nonspecific adnexal lesions in 61 patients. CEUS was performed with a 4.8-ml bolus of a second-generation ultrasonographic contrast agent and dedicated imaging algorithms. For each lesion, B-mode morphology, CEUS morphology, and time/intensity curves were evaluated. In 8/61 cases (13.1%) CEUS offered no additional morphovascular information. In 38/61 cases (62.3%), it provided additional information that did not modify the management of the lesion, and in 15/61 cases (24.6%) it gave additional information that modified the management of the lesion. Malignant lesions were characterized by significantly shorter times to peak enhancement (11.9 ± 3.1 s vs 19.8 ± 4.0 s p < 0.01) and significantly higher peak intensity (24.7 ± 4.2 dB vs 17.8 ± 3.3 dB p < 0.01) compared with benign lesions. CEUS improves diagnostic confidence in the characterization of liquid-corpuscular lesions where conventional US is inconclusive. CEUS can be proposed as a valid alternative to CT and MR. However, information obtained by CEUS influences the therapy in a limited percentage of cases (24.6%).

  14. Real-time contrast-enhanced ultrasound in diagnosing of focal spleen lesions

    International Nuclear Information System (INIS)

    Yu Xiaoling; Yu Jie; Liang Ping; Liu Fangyi

    2012-01-01

    Objective: To investigate the features of focal spleen lesions (FSLs) on contrast-enhanced ultrasound (CEUS) imaging. Materials and methods: CEUS with a blot injection of SonoVue was performed in 48 patients with 75 FSLs (median diameter 2.6 cm) and their perfusion characteristics were analyzed by using contrast pulse sequences (CPS) technique. Results: Among 19 malignant lesions (10 metastases, 7 lymphoma, 1 hemangiosarcoma, 1 epithelioid hemangioendothelioma) and 56 benign lesion (23 hemangiomas, 14 cysts, 8 infarctions, 4 splenic ruptures, 3 tuberculosis, 2 abscess, 1 pseudoaneurysm, 1 lymphangioma), 25 benign lesions were demonstrated nonenhancement. For malignancy, 50.0% (5/10) metastases and 57.1% (4/7) lymphomas were showed hypoenhancement in the arterial phase, and 18 (94.7%) of malignant lesions were hypo-enhancement in the parenchymal phase. Among 31 benign lesions with enhancement, 27 (87.1%) were showed isoenhancement or hyperenhancement in the arterial phase and 22 (71.0%) lesions were isoenhancement or hyperenhancement in the parenchymal phase. The sensitivity, specificity and accuracy of diagnosis for FSLs were 91.1%, 95.0% and 92.0% for CEUS and 75.0%, 84.2% and 77.3% respectively, for the conventional baseline ultrasound (BUS). Conclusion: Real-time CEUS can provide valuable information for the diagnosis and differential diagnosis of FSLs.

  15. Real-time tracheal ultrasonography for confirmation of endotracheal tube placement during cardiopulmonary resuscitation.

    Science.gov (United States)

    Chou, Hao-Chang; Chong, Kah-Meng; Sim, Shyh-Shyong; Ma, Matthew Huei-Ming; Liu, Shih-Hung; Chen, Nai-Chuan; Wu, Meng-Che; Fu, Chia-Ming; Wang, Chih-Hung; Lee, Chien-Chang; Lien, Wan-Ching; Chen, Shyr-Chyr

    2013-12-01

    This study aimed to evaluate the accuracy of tracheal ultrasonography for assessing endotracheal tube position during cardiopulmonary resuscitation (CPR). We performed a prospective observational study of patients undergoing emergency intubation during CPR. Real-time tracheal ultrasonography was performed during the intubation with the transducer placed transversely just above the suprasternal notch, to assess for endotracheal tube positioning and exclude esophageal intubation. The position of trachea was identified by a hyperechoic air-mucosa (A-M) interface with posterior reverberation artifact (comet-tail artifact). The endotracheal tube position was defined as endotracheal if single A-M interface with comet-tail artifact was observed. Endotracheal tube position was defined as intraesophageal if a second A-M interface appeared, suggesting a false second airway (double tract sign). The gold standard of correct endotracheal intubation was the combination of clinical auscultation and quantitative waveform capnography. The main outcome was the accuracy of tracheal ultrasonography in assessing endotracheal tube position during CPR. Among the 89 patients enrolled, 7 (7.8%) had esophageal intubations. The sensitivity, specificity, positive predictive value, and negative predictive value of tracheal ultrasonography were 100% (95% confidence interval [CI]: 94.4-100%), 85.7% (95% CI: 42.0-99.2%), 98.8% (95% CI: 92.5-99.0%) and 100% (95% CI: 54.7-100%), respectively. Positive and negative likelihood ratios were 7.0 (95% CI: 1.1-43.0) and 0.0, respectively. Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during CPR without the need for interruption of chest compression. Tracheal ultrasonography in resuscitation management may serve as a powerful adjunct in trained hands. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. Preoperative radiological characterization of hepatic angiomyolipoma using magnetic resonance imaging and contrast-enhanced ultrasonography: a case report

    Directory of Open Access Journals (Sweden)

    Schmid Roland M

    2011-09-01

    Full Text Available Abstract Introduction A hepatic angiomyolipoma is a rare benign tumor of the liver composed of a mixture of smooth muscle cells, blood vessels and a variable amount of adipose tissue. Differentiating them from malignant liver tumors can often be very difficult. Case presentation We report the case of a 43-year-old Caucasian man presenting with a large liver mass in the right lobe. The results of magnetic resonance imaging and contrast-enhanced ultrasonography were consistent with a well-demarcated adipose tissue- containing tumor, showing prolonged hyperperfusion in comparison with the surrounding liver tissue. Surgery was performed and the diagnosis of hepatic angiomyolipoma was made with histopathology. Conclusion Preoperative radiological characterization using magnetic resonance imaging and contrast-enhanced ultrasonography may improve diagnostic accuracy of hepatic angiomyolipoma. Identification of smooth muscle cells, blood vessels and adipose tissue with a positive immunohistochemical reaction for HMB-45 is the final evidence for an angiomyolipoma.

  17. Features of time–intensity curve parameters of colorectal adenocarcinomas evaluated by double-contrast enhanced ultrasonography: Initial observation

    International Nuclear Information System (INIS)

    Zhuang Hua; Yang Zhigang; Wang Ziqiang; Wang Xiaodong; Chen Huijiao; Zhang Yuanchuan; Luo Yan

    2012-01-01

    Purpose: This study is to investigate the value of double contrast-enhanced ultrasonography (DCEU) in assessing microcirculation of colorectal adenocarcinomas and to describe the perfusion features of the tumours. Material and methods: DCEUS was performed in 42 patients with adenocarcinoma. The time–intensity curve parameters (arrival time (AT), time-to-peak (TTP), peak intensity (PI) and area under the curve (AUC)) within the tumours were extracted. The parameters were compared among the tumours with different CEUS features and stages. Results: The mean values of AT, TTP, PI and AUC of the colorectal adenocarcinomas were 13.68 ± 13.36 s, 32.61 ± 19.56 s, 19.82 ± 16.54 dB and 271.10 ± 159.19 dB s, respectively. In the adenocarcinomas with necrosis, the mean values of AUC was significantly lower than that of the adenocarcinomas without (231.10 ± 219.27 dB s, 278.10 ± 123.20 dB s, p = 0.004). In the adenocarcinomas with necrosis, the AUC and PI of the non-necrotic part were significantly higher than that of the necrotic part (p = 0.007, 0.0025, respectively). AUC increased progressively in the subgroups of T2, T3 and T4 and the difference of AUC between T2 and T4 subgroup was significant (p = 0.008). Conclusions: Double contrast-enhanced ultrasonography is a valuable technique for quantifying tumour vascularity of colorectal adenocarcinomas. AUC was significantly different in the subgroups of different T stage. AUC and PI could reflect the different perfusion status of tumours with or without necrosis.

  18. Transabdominal Ultrasonography of the Small Bowel

    Directory of Open Access Journals (Sweden)

    Rudolf Kralik

    2013-01-01

    Full Text Available In the era of double balloon enteroscopy, capsule endoscopy, CT, and MRI enterography is transabdominal ultrasonography (TUS underestimated method for evaluation of small bowel pathology. As often initial imagine method in abdominal complaints, nowadays has TUS much better diagnostic potential than two decades ago. High-resolution ultrasound probes with harmonic imaging significantly improve resolution of bowel wall in real time, with possibility to asses bowel peristalsis. Color flow doppler enables evaluation of intramural bowel vascularisation, pulse wave doppler helps to quantificate flow in coeliac and superior mesenteric arteries. Small intestine contrast ultrasonography with oral contrast fluid, as well as contrast enhanced ultrasonography with intravenous microbubble contrast also improves small bowel imaging. We present a review of small intestine pathology that should be detected during ultrasound examinations, discuss technical requirements, advantages and limitations of TUS, typical ultrasound signs of Crohn's disease, ileus, celiac disease, intussusception, infectious enteritis, tumours, ischemic and haemorrhagic conditions of small bowel. In the hands of experienced investigator, despite some significant limitations(obesity, meteorism, is transabdominal ultrasonography reliable, noninvasive and inexpensive alternative method to computerised tomography (CT and magnetic resonance imaging (MRI in small bowel examination.

  19. Contrast-enhanced Harmonic power Doppler ultrasonography: Improved depiction of vascularity and characterization of flow pattern in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Baek, Hyung Chul; Yoon, Kwon Ha; Kim, Chang Guhn; Park, Ki Han; Won, Jong Jin

    2000-01-01

    To evaluate the value of contrast-enhanced harmonic power Doppler ultrasonography (PDUS) in depiction and characterization of tumoral vascularity in hepatocellular carcinoma (HCC). Thirty-three patients with HCC were prospectively evaluated with harmonic PDUS before and after injection of the contrast agent SH U 508A (2.5g, 300 mg/ml ). Unenhanced and serial dynamic scans at 15, 30, 45, 60, 90, 120, 150, 180, 240, 300 seconds after injection of contrast agents were obtained using a tissue harmonic technique with power Doppler imaging. The tumoral vascularity was expressed as percentage of power Doppler area, which was measured quantitatively by a computerized program (Ultrasonic Imaging Tool; Soongsil University, Seoul, Korea). The grade (0, no signal; 1, less than 5%; 2, 5-25%; 3, more than 25%) and flow pattern (intratumoral, detour, basket, and mixed) of tumoral vascularity were analyzed. Peak time of contrast-enhancement was measured on each tumor. After injection of contrast agent, tumoral flow signals increased in all lesions (100%). At unenhanced harmonic PDUS, flow signals were detected in 17 HCCs (52%); 15 tumors (46%) demonstrated grade 1 vascularity; and two (6%), grade 2. At contrast-enhanced harmonic PDUS, all tumors were detected vascularity; five (15%) were grade 1; eight (24%), grade 2; and 20 (61%), grade 3. Flow patterns were demonstated as follows at unenhanced harmonic PDUS; intratumoral pattern in 13 tumors (76%), detour in 2 (12%), and basket in 2 (12%). After injection of contrast agent, intratumoral pattern in 7 tumors (21%), detour 0 (0%), basket in 3 (9%) and mixed in 23 (70%) were demonstrated. Peak time of enhancement after injection of contrast agent was 30- 90 seconds in majority of the patients. Contrast-enhanced harmonic PDUS would be valuable in depiction of vascularity and characterization of flow pattern in HCC.

  20. Contrast-enhanced Harmonic power Doppler ultrasonography: Improved depiction of vascularity and characterization of flow pattern in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Hyung Chul; Yoon, Kwon Ha; Kim, Chang Guhn; Park, Ki Han; Won, Jong Jin [Wonkwang University School of Medicine, Iksa (Korea, Republic of)

    2000-12-15

    To evaluate the value of contrast-enhanced harmonic power Doppler ultrasonography (PDUS) in depiction and characterization of tumoral vascularity in hepatocellular carcinoma (HCC). Thirty-three patients with HCC were prospectively evaluated with harmonic PDUS before and after injection of the contrast agent SH U 508A (2.5g, 300 mg/ml ). Unenhanced and serial dynamic scans at 15, 30, 45, 60, 90, 120, 150, 180, 240, 300 seconds after injection of contrast agents were obtained using a tissue harmonic technique with power Doppler imaging. The tumoral vascularity was expressed as percentage of power Doppler area, which was measured quantitatively by a computerized program (Ultrasonic Imaging Tool; Soongsil University, Seoul, Korea). The grade (0, no signal; 1, less than 5%; 2, 5-25%; 3, more than 25%) and flow pattern (intratumoral, detour, basket, and mixed) of tumoral vascularity were analyzed. Peak time of contrast-enhancement was measured on each tumor. After injection of contrast agent, tumoral flow signals increased in all lesions (100%). At unenhanced harmonic PDUS, flow signals were detected in 17 HCCs (52%); 15 tumors (46%) demonstrated grade 1 vascularity; and two (6%), grade 2. At contrast-enhanced harmonic PDUS, all tumors were detected vascularity; five (15%) were grade 1; eight (24%), grade 2; and 20 (61%), grade 3. Flow patterns were demonstated as follows at unenhanced harmonic PDUS; intratumoral pattern in 13 tumors (76%), detour in 2 (12%), and basket in 2 (12%). After injection of contrast agent, intratumoral pattern in 7 tumors (21%), detour 0 (0%), basket in 3 (9%) and mixed in 23 (70%) were demonstrated. Peak time of enhancement after injection of contrast agent was 30- 90 seconds in majority of the patients. Contrast-enhanced harmonic PDUS would be valuable in depiction of vascularity and characterization of flow pattern in HCC.

  1. Gray-scale contrast-enhanced utrasonography in detecting sentinel lymph nodes: An animal study

    International Nuclear Information System (INIS)

    Wang Yuexiang; Cheng Zhigang; Li Junlai; Tang Jie

    2010-01-01

    Objective: To investigate the usefulness of gray-scale contrast-enhanced ultrasonography for detecting sentinel lymph nodes. Methods: Contrast-enhanced ultrasonography was performed in five normal dogs (four female and one male) after subcutaneous administration of a sonographic contrast agent (Sonovue, Bracco, Milan, Italy). Four distinct regions in each animal were examined. After contrast-enhanced ultrasonography, 0.8 ml of blue dye was injected into the same location as Sonovue and the sentinel lymph nodes were detected by surgical dissection. The findings of contrast-enhanced ultrasonography were compared with those of the blue dye. Results: Twenty-one sentinel lymph nodes were detected by contrast-enhanced ultrasonography while 23 were identified by blue dye with surgical dissection. Compared with the blue dye, the detection rate of enhanced ultrasonography for the sentinel lymph nodes is 91.3% (21/23). Two patterns of enhancement in the sentinel lymph nodes were observed: complete enhancement (5 sentinel lymph nodes) and partial enhancement (16 sentinel lymph nodes). The lymphatic channels were demonstrated as hyperechoic linear structures leading from the injection site and could be readily followed to their sentinel lymph nodes. Histopathologic examination showed proliferation of lymphatic follicles or lymphatic sinus in partial enhanced sentinel lymph nodes while normal lymphatic tissue was demonstrated in completely enhanced sentinel lymph nodes. Conclusions: Sonovue combined with gray-scale contrast-enhanced ultrasonography may provide a feasible method for detecting sentinel lymph nodes.

  2. Severe portal hypertension in cirrhosis: evaluation of perfusion parameters with contrast-enhanced ultrasonography.

    Directory of Open Access Journals (Sweden)

    Woo Kyoung Jeong

    Full Text Available To investigate the role of contrast-enhanced ultrasonography (CEUS and Doppler ultrasonography (DUS in the diagnosis of severe portal hypertension (PH in patients with liver cirrhosis (LC.Patients with PH scheduled to receive hepatic venous pressure gradient (HVPG measurement were recruited for this study. Hepatic DUS and CEUS were performed successively. Several Doppler and CEUS parameters were explored for correlation with HVPG values and their association with severe PH (≥ 12 mmHg of HVPG. Comparison of the parameters between the severe and non-severe PH groups and their correlation with HVPG values was evaluated. A receiver operating characteristic (ROC curve analysis was also performed to investigate the performance in order to diagnose severe PH.Fifty-three consecutive patients were enrolled in this study. Among them, 43 patients did not have significant ascites. Compared with the non-severe PH group, portal venous velocity and intrahepatic transit time (ITT were significantly reduced in the severe PH group (all p<0.05. Difference between inspiratory and expiratory hepatic venous damping indices (ΔHVDI, hepatic venous arrival time (HVAT and ITT moderately correlated with HVPG (r = -0.358, -0.338, and -0.613, respectively. Areas under the curves for severe PH were 0.94 of ITT and 0.72 of HVAT, respectively (all p<0.05. ITT under 6 seconds indicated severe PH with a sensitivity of 92% and a specificity of 89%.Hepatic CEUS may be more useful in estimating the HVPG value and determining the presence of severe PH compared to DUS, and ITT was the most accurate parameter to diagnose severe PH.

  3. Vascular patterns in nodules of intraductal papillary mucinous neoplasms depicted under contrast-enhanced ultrasonography are helpful for evaluating malignant potential

    International Nuclear Information System (INIS)

    Kurihara, Naoko; Kawamoto, Hirofumi; Kobayashi, Yoshiyuki; Okamoto, Yuko; Yamamoto, Naoki; Tsutsumi, Koichiro; Fujii, Masakuni; Kato, Hironari; Yamamoto, Kazuhide

    2012-01-01

    Objectives: The purpose of this study is to evaluate the feasibility of contrast-enhanced ultrasonography (CE-US) to differentiate between benign and malignant intraductal papillary mucinous neoplasms (IPMN). Patients and methods: Contrast-enhanced ultrasonography with a contrast agent was performed on 22 consecutive patients with IPMN suspected of being malignant. This revealed 10 carcinomas, 1 borderline lesion and 11 adenomas. All patients underwent surgery, and the histological diagnosis was confirmed by examination of resected specimens. CE-US was performed using a contrast agent. The detection rates of mural nodules were compared between CE-US and contrast-enhanced computed tomography (CE-CT), and the imaging of mural nodules depicted under CE-US was analyzed. Results: Seventeen of 22 resected specimens (77.3%) had mural nodules. There was no significant difference in the detection rate between CE-US (n = 15; 88.2%) and CE-CT (n = 12; 70.6%). In 12 (80.0%) of these patients, CE-US revealed small vessels in the mural nodule. The spotty or linear-shaped pattern was detected in 4 patients and the branch-shaped pattern in 8. The branch-shaped pattern lesion was associated with carcinoma. These mural nodules were 10 mm or more in height. In the perfusion image phase, cystic walls and mural nodules were also enhanced in all cases. Conclusion: The vessel shapes of the mural nodules depicted under CE-US were associated with size and pathological findings. These results suggested that CE-US with a contrast agent is a powerful modality with which to evaluate the malignant potential of IPMN.

  4. Diagnostic performance of fluorodeoxyglucose-positron emission tomography/computed tomography of breast cancer in detecting axillary lymph node metastasis. Comparison with ultrasonography and contrast-enhanced CT

    International Nuclear Information System (INIS)

    Monzawa, Shuichi; Adachi, Shuji; Suzuki, Kayo; Hirokaga, Koichi; Takao, Shintaro; Sakuma, Toshiko; Hanioka, Keisuke

    2009-01-01

    The purpose of this retrospective study was to evaluate the diagnostic performance of positron emission tomography/computed tomography (PET/CT) with fluorine-18-labeled 2-fluoro-2-deoxy-D-glucose (FDG) in comparison with that of ultrasonography and contrast-enhanced computed tomography (CT) in detecting axillary lymph node metastasis in patients with breast cancer. Fifty patients with invasive breast cancer were recruited. They had received no neoadjuvant chemotherapy and underwent PET/CT, ultrasonography and contrast-enhanced CT before mastectomy. The clinical stage was I in 34 patients, II in 15 patients, and III in one patient. The images of these modalities were interpreted in usual practice before surgery and the diagnostic reports were reviewed for analysis. Sensitivity, specificity, positive predictive value, and negative predictive value of each modality were obtained taking histopathological results of axillary lymph node dissection or sentinel lymph node biopsy as the reference standard. Axillary lymph node metastasis was confirmed in 15 of 50 patients by histopathological studies. PET/CT identified lymph node metastasis in three of these 15 patients. The overall sensitivity and specificity, positive predictive value, and negative predictive value of PET/CT in the diagnosis of axillary lymph node metastasis were 20, 97, 75, and 74%, and those of ultrasonography were 33, 94, 71, and 77% and those of contrast-enhanced CT were 27, 97, 80, and 76%, respectively. PET/CT showed poor sensitivity and high specificity in the detection of axillary lymph node metastasis of breast cancer. Diagnostic performance of PET/CT was not superior to that of ultrasonography and contrast-enhanced CT. (author)

  5. Quantitative analysis of contrast-enhanced ultrasonography of the bowel wall can predict disease activity in inflammatory bowel disease

    Energy Technology Data Exchange (ETDEWEB)

    Romanini, Laura, E-mail: laura.romanini@libero.it [Department of Radiology, Spedali Civili di Brescia, P.le Spedali Civili, 1, 25123 Brescia (Italy); Passamonti, Matteo, E-mail: matteopassamonti@gmail.com [Department of Radiology-AO Provincia di Lodi, Via Fissiraga, 15, 26900 Lodi (Italy); Navarria, Mario, E-mail: navarria.mario@tiscali.it [Department of Radiology-ASL Vallecamonica-Sebino, Via Manzoni 142, 25040 Esine, BS (Italy); Lanzarotto, Francesco, E-mail: francesco.lanzarotto@spedalicivili.brescia.it [Department of Gastroenterology, Spedali Civili di Brescia, P.le Spedali Civili, 1, 25123 Brescia (Italy); Villanacci, Vincenzo, E-mail: villanac@alice.it [Department of Pathology, Spedali Civili di Brescia, P.le Spedali Civili, 1, 25123 Brescia (Italy); Grazioli, Luigi, E-mail: radiologia1@spedalicivili.brescia.it [Department of Radiology, Spedali Civili di Brescia, P.le Spedali Civili, 1, 25123 Brescia (Italy); Calliada, Fabrizio, E-mail: fabrizio.calliada@gmail.com [Department of Radiology, University of Pavia, Viale Camillo Golgi 19, 27100 Pavia (Italy); Maroldi, Roberto, E-mail: rmaroldi@gmail.com [Department of Radiology, University of Brescia, P.le Spedali Civili, 1, 25123 Brescia (Italy)

    2014-08-15

    Purpose: To evaluate the accuracy of quantitative analysis of bowel wall enhancement in inflammatory bowel disease (IBD) with contrast enhanced ultrasound (CEUS) by comparing the results with vascular density in a biopsy sample from the same area of the intestinal tract, and to determine the usefulness of this analysis for the prediction of disease activity. Materials and methods: This prospective study was approved by our institute's ethics committee and all patients gave written informed consent. We enrolled 33 consecutive adult patients undergoing colonoscopy and biopsy for IBD. All patients underwent CEUS and the results were quantitatively analyzed. Vessel count per high-power field on biopsy specimens was compared with colonoscopy, baseline ultrasonography, and CEUS findings, and with analysis of peak intensity, time to peak, regional blood volume, mean transit time, and regional blood flow. Results in patients with high and low vascular density were compared using Fisher's test, t-test, Pearson's correlation test, and receiver operating characteristic curve (ROC) analysis. Cutoff values were determined using ROC analysis, and sensitivity and specificity were calculated. Results: High vascular density (>265 vessels per field) on histological examination was significantly correlated with active disease on colonoscopy, baseline ultrasonography, and CEUS (p < .0001). Quantitative analysis showed a higher enhancement peak, a shorter time to peak enhancement, a higher regional blood flow and regional blood volume in patients with high vascular density than in those with low vascular density. Cutoff values to distinguish between active and inactive disease were identified for peak enhancement (>40.5%), and regional blood flow (>54.8 ml/min). Conclusion: Quantitative analysis of CEUS data correlates with disease activity as determined by vascular density. Quantitative parameters of CEUS can be used to predict active disease with high sensitivity and

  6. Quantitative analysis of contrast-enhanced ultrasonography of the bowel wall can predict disease activity in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Romanini, Laura; Passamonti, Matteo; Navarria, Mario; Lanzarotto, Francesco; Villanacci, Vincenzo; Grazioli, Luigi; Calliada, Fabrizio; Maroldi, Roberto

    2014-01-01

    Purpose: To evaluate the accuracy of quantitative analysis of bowel wall enhancement in inflammatory bowel disease (IBD) with contrast enhanced ultrasound (CEUS) by comparing the results with vascular density in a biopsy sample from the same area of the intestinal tract, and to determine the usefulness of this analysis for the prediction of disease activity. Materials and methods: This prospective study was approved by our institute's ethics committee and all patients gave written informed consent. We enrolled 33 consecutive adult patients undergoing colonoscopy and biopsy for IBD. All patients underwent CEUS and the results were quantitatively analyzed. Vessel count per high-power field on biopsy specimens was compared with colonoscopy, baseline ultrasonography, and CEUS findings, and with analysis of peak intensity, time to peak, regional blood volume, mean transit time, and regional blood flow. Results in patients with high and low vascular density were compared using Fisher's test, t-test, Pearson's correlation test, and receiver operating characteristic curve (ROC) analysis. Cutoff values were determined using ROC analysis, and sensitivity and specificity were calculated. Results: High vascular density (>265 vessels per field) on histological examination was significantly correlated with active disease on colonoscopy, baseline ultrasonography, and CEUS (p < .0001). Quantitative analysis showed a higher enhancement peak, a shorter time to peak enhancement, a higher regional blood flow and regional blood volume in patients with high vascular density than in those with low vascular density. Cutoff values to distinguish between active and inactive disease were identified for peak enhancement (>40.5%), and regional blood flow (>54.8 ml/min). Conclusion: Quantitative analysis of CEUS data correlates with disease activity as determined by vascular density. Quantitative parameters of CEUS can be used to predict active disease with high sensitivity and

  7. Quantitative Assessment of Synovial Vascularity Using Contrast-Enhanced Power Doppler Ultrasonography: Correlation with Histologic Findings and MR Imaging Findings in Arthritic Rabbit Knee Model

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Shin, Myung Jin; Kim, Seong Moon; Kim, Namkug; Suh, Sang Hyun; Suh, Jin Suck

    2008-01-01

    To validate contrast-enhanced power Doppler ultrasonography (PD US) for the evaluation of synovial vascularity in an arthritic rabbit knee model in correlation with MR and histological findings. Power Doppler ultrasonography was performed for carrageenin-induced arthritic left knee and control right knee of 13 rabbits, first without and then with sonic contrast agent enhancement (Levovist, Schering, Berlin Germany), followed by gadolinium-enhanced MR imaging. Synovial vascularity was quantitatively assessed by calculating the color pixel area in power Doppler sonography using a computer-aided image analysis program and by grading the enhancement on MR images: grade 1, enhancement of knee joint is less than one-third of the area; grade 2, one-third to two-thirds enhancement; and grade 3, more than two-thirds enhancement. Microvessel density (MVD) was measured on slides stained immunohistochemically for CD31 antigen for histological assessment. The mean area of color pixels in PD US changed from 4.37 to 16.42 mm 2 in the arthritic knee after enhancement (p 2 in the control knee (p 0.05). Sonic contrast-enhanced PD US improves the visualization of synovial vascularity and allows quantitative measurement in experimentally induced rabbit arthritic knees

  8. Assessment of contrast-enhanced ultrasonography of the hepatic vein for detection of hemodynamic changes associated with experimentally induced portal hypertension in dogs.

    Science.gov (United States)

    Morishita, Keitaro; Hiramoto, Akira; Michishita, Asuka; Takagi, Satoshi; Hoshino, Yuki; Itami, Takaharu; Lim, Sue Yee; Osuga, Tatsuyuki; Nakamura, Sayuri; Ochiai, Kenji; Nakamura, Kensuke; Ohta, Hiroshi; Yamasaki, Masahiro; Takiguchi, Mitsuyoshi

    2017-04-01

    OBJECTIVE To assess the use of contrast-enhanced ultrasonography (CEUS) of the hepatic vein for the detection of hemodynamic changes associated with experimentally induced portal hypertension in dogs. ANIMALS 6 healthy Beagles. PROCEDURES A prospective study was conducted. A catheter was surgically placed in the portal vein of each dog. Hypertension was induced by intraportal injection of microspheres (10 to 15 mg/kg) at 5-day intervals via the catheter. Microsphere injections were continued until multiple acquired portosystemic shunts were created. Portal vein pressure (PVP) was measured through the catheter. Contrast-enhanced ultrasonography was performed before and after establishment of hypertension. Time-intensity curves were generated from the region of interest in the hepatic vein. Perfusion variables measured for statistical analysis were hepatic vein arrival time, time to peak, time to peak phase (TTPP), and washout ratio. The correlation between CEUS variables and PVP was assessed by use of simple regression analysis. RESULTS Time to peak and TTPP were significantly less after induction of portal hypertension. Simple regression analysis revealed a significant negative correlation between TTPP and PVP. CONCLUSIONS AND CLINICAL RELEVANCE CEUS was useful for detecting hemodynamic changes associated with experimentally induced portal hypertension in dogs, which was characterized by a rapid increase in the intensity of the hepatic vein. Furthermore, TTPP, a time-dependent variable, provided useful complementary information for predicting portal hypertension. IMPACT FOR HUMAN MEDICINE Because the method described here induced presinusoidal portal hypertension, these results can be applied to idiopathic portal hypertension in humans.

  9. Improved outcome of percutaneous radiofrequency ablation in renal cell carcinoma: a retrospective study of intraoperative contrast-enhanced ultrasonography in 73 patients.

    Science.gov (United States)

    Zhao, Xiaozhi; Wang, Wei; Zhang, Shiwei; Liu, Jun; Zhang, Fan; Ji, Changwei; Li, Xiaogong; Gan, Weidong; Zhang, Gutian; Guo, Hongqian

    2012-10-01

    To evaluate the impact of contrast-enhanced ultrasonography (CEUS) during percutaneous radiofrequency ablation (PRFA) procedure in renal cell carcinoma (RCC). From January 2008 to July 2010, 73 patients with sporadic unilateral RCC were enrolled to our study (57 men and 16 women, age range: 37-78 years, mean age 57.9 years). The diameter of the tumor was 1.7-5.8, 3.4 cm on average. The patients were divided into two groups depending on the intraoperative ultrasonography type: CEUS group and conventional ultrasound group. Patients in CEUS group received CEUS before insertion of the electrode, and the second CEUS was performed right after the initial ablation to dynamically evaluate the images. If there was highly suspicious residue, additional ablation and repeated CEUS were applied. Patients in the conventional ultrasound group received PRFA guided by gray-scale ultrasound. All of these patients received contrast-enhanced computed tomography (CT) examination 7 days after the procedure (patients in CEUS group received CEUS conducted with each CT scan), with subsequent CT and CEUS assessment at 3, 6, and every 6 months thereafter. The mean follow-up period was 22 months (range: 12-42 months). All tumors were biopsied before RFA. The local tumor control rate was 94.6% (35/37) in the CEUS group and 86.1% (31/36) in the conventional ultrasound group (P 73 m(2) (P > 0.05, compared with pre-GFR: 86.4 ± 26.2 mL/min/1.73 m(2)) in the CEUS group and 81.9 ± 22.8 mL/min/1.73 m(2) (P > 0.05, compared with pre-GFR: 83.5 ± 23.7 mL/min/1.73 m(2)) in the conventional ultrasound group. Intraoperative CEUS can "real-time" monitor the ablated area during PRFA procedure. This technique can help to achieve a higher success rate compared with conventional ultrasound. No impact of intraoperative CEUS has been found on GFR level.

  10. Unenhanced and Contrast-Enhanced Ultrasonography During Hepatic Transarterial Embolization and Chemoembolization With Drug-Eluting Beads

    International Nuclear Information System (INIS)

    Moschouris, Hippocrates; Malagari, Katerina; Kornezos, Ioannis; Papadaki, Marina Georgiou; Gkoutzios, Panagiotis; Matsaidonis, Dimitrios

    2010-01-01

    The purpose of this study was to describe and evaluate the findings of unenhanced ultrasonography (US) and contrast-enhanced ultrasonography (CEUS) when these modalities are applied during transarterial embolization (TAE) or transarterial chemoembolization (TACE) of liver tumors. Sixteen tumors (9 hepatocellular carcinomas, 5 metastases from colorectal cancer, and 2 hemangiomas) were treated with TAE with microspheres and/or TACE with drug-eluting beads. All of these lesions were studied with intraprocedural unenhanced US and 12 were studied with intraprocedural CEUS. For the latter, a second-generation echo-enhancer (SonoVue; Bracco, Milan, Italy) and a low mechanical index technique were used. Intraprocedural findings were classified according to an arbitrary scale and were compared with pretreatment imaging (CEUS and computed tomography or CEUS and magnetic resonance imaging), with postembolization angiography, and with follow-up results. On unenhanced intraprocedural US, 13 of 16 tumors demonstrated intralesional high-level echoes of varying extent. These feature correlated poorly (r = 0.33, p = 0.097) with and generally underestimated the actual extent of necrosis. Exceptionally, high-level echoes that occupied the largest part of the treated lesions were associated with >50% tumor necrosis. Intraprocedural CEUS clearly depicted immediate partial or complete disappearance of tumor enhancement as a result of TAE/TACE. Three of 6 tumors with complete devascularization on postembolization angiogram showed residual enhancement on intraprocedural CEUS. Intraprocedural CEUS findings correlated closely (r = 0.91, p = 0.002) with follow-up findings. Intraprocedural sonography, particularly with echo-enhancers, could be used for intraprocedural monitoring in selected cases of liver tumors that undergo TAE or TACE.

  11. Clinical utility of three-dimensional contrast-enhanced ultrasound in the differentiation between noninvasive and invasive neoplasms of urinary bladder.

    Science.gov (United States)

    Li, Qiu-yang; Tang, Jie; He, En-hui; Li, Yan-mi; Zhou, Yun; Zhang, Xu; Chen, Guangfu

    2012-11-01

    The purpose of this study was to evaluate the effectiveness of three-dimensional contrast-enhanced ultrasound in differentiating invasive and noninvasive neoplasms of urinary bladder. A total of 60 lesions in 60 consecutive patients with bladder tumors received three dimensional ultrasonography, low acoustic power contrast enhanced ultrasonography and low acoustic power three-dimensional contrast-enhanced ultrasound examination. The IU22 ultrasound scanner and a volume transducer were used and the ultrasound contrast agent was SonoVue. The contrast-specific sonographic imaging modes were PI (pulse inversion) and PM (power modulation). The three dimensional ultrasonography, contrast enhanced ultrasonography, and three-dimensional contrast-enhanced ultrasound images were independently reviewed by two readers who were not in the images acquisition. Images were analyzed off-site. A level of confidence in the diagnosis of tumor invasion of the muscle layer was assigned on a 5° scale. Receiver operating characteristic analysis was used to assess overall confidence in the diagnosis of muscle invasion by tumor. Kappa values were used to assess inter-readers agreement. Histologic diagnosis was obtained for all patients. Final pathologic staging revealed 44 noninvasive tumors and 16 invasive tumors. Three-dimensional contrast-enhanced ultrasound depicted all 16 muscle-invasive tumors. The diagnostic performance of three-dimensional contrast-enhanced ultrasound was better than those of three dimensional ultrasonography and contrast enhanced ultrasonography. The receiver operating characteristic curves were 0.976 and 0.967 for three-dimensional contrast-enhanced ultrasound, those for three dimensional ultrasonography were 0.881 and 0.869, those for contrast enhanced ultrasonography were 0.927 and 0.929. The kappa values in the three dimensional ultrasonography, contrast enhanced ultrasonography and three-dimensional contrast-enhanced ultrasound for inter-reader agreements

  12. Clinical utility of three-dimensional contrast-enhanced ultrasound in the differentiation between noninvasive and invasive neoplasms of urinary bladder

    International Nuclear Information System (INIS)

    Li, Qiu-yang; Tang, Jie; He, En-hui; Li, Yan-mi; Zhou, Yun; Zhang, Xu; Chen, Guangfu

    2012-01-01

    Objectives: The purpose of this study was to evaluate the effectiveness of three-dimensional contrast-enhanced ultrasound in differentiating invasive and noninvasive neoplasms of urinary bladder. Methods: A total of 60 lesions in 60 consecutive patients with bladder tumors received three dimensional ultrasonography, low acoustic power contrast enhanced ultrasonography and low acoustic power three-dimensional contrast-enhanced ultrasound examination. The IU22 ultrasound scanner and a volume transducer were used and the ultrasound contrast agent was SonoVue. The contrast-specific sonographic imaging modes were PI (pulse inversion) and PM (power modulation). The three dimensional ultrasonography, contrast enhanced ultrasonography, and three-dimensional contrast-enhanced ultrasound images were independently reviewed by two readers who were not in the images acquisition. Images were analyzed off-site. A level of confidence in the diagnosis of tumor invasion of the muscle layer was assigned on a 5° scale. Receiver operating characteristic analysis was used to assess overall confidence in the diagnosis of muscle invasion by tumor. Kappa values were used to assess inter-readers agreement. Histologic diagnosis was obtained for all patients. Results: Final pathologic staging revealed 44 noninvasive tumors and 16 invasive tumors. Three-dimensional contrast-enhanced ultrasound depicted all 16 muscle-invasive tumors. The diagnostic performance of three-dimensional contrast-enhanced ultrasound was better than those of three dimensional ultrasonography and contrast enhanced ultrasonography. The receiver operating characteristic curves were 0.976 and 0.967 for three-dimensional contrast-enhanced ultrasound, those for three dimensional ultrasonography were 0.881 and 0.869, those for contrast enhanced ultrasonography were 0.927 and 0.929. The kappa values in the three dimensional ultrasonography, contrast enhanced ultrasonography and three-dimensional contrast-enhanced ultrasound

  13. A contrast enhancement method for improving the segmentation of breast lesions on ultrasonography.

    Science.gov (United States)

    Flores, Wilfrido Gómez; Pereira, Wagner Coelho de Albuquerque

    2017-01-01

    This paper presents an adaptive contrast enhancement method based on sigmoidal mapping function (SACE) used for improving the computerized segmentation of breast lesions on ultrasound. First, from the original ultrasound image an intensity variation map is obtained, which is used to generate local sigmoidal mapping functions related to distinct contextual regions. Then, a bilinear interpolation scheme is used to transform every original pixel to a new gray level value. Also, four contrast enhancement techniques widely used in breast ultrasound enhancement are implemented: histogram equalization (HEQ), contrast limited adaptive histogram equalization (CLAHE), fuzzy enhancement (FEN), and sigmoid based enhancement (SEN). In addition, these contrast enhancement techniques are considered in a computerized lesion segmentation scheme based on watershed transformation. The performance comparison among techniques is assessed in terms of both the quality of contrast enhancement and the segmentation accuracy. The former is quantified by the measure, where the greater the value, the better the contrast enhancement, whereas the latter is calculated by the Jaccard index, which should tend towards unity to indicate adequate segmentation. The experiments consider a data set with 500 breast ultrasound images. The results show that SACE outperforms its counterparts, where the median values for the measure are: SACE: 139.4, SEN: 68.2, HEQ: 64.1, CLAHE: 62.8, and FEN: 7.9. Considering the segmentation performance results, the SACE method presents the largest accuracy, where the median values for the Jaccard index are: SACE: 0.81, FEN: 0.80, CLAHE: 0.79, HEQ: 77, and SEN: 0.63. The SACE method performs well due to the combination of three elements: (1) the intensity variation map reduces intensity variations that could distort the real response of the mapping function, (2) the sigmoidal mapping function enhances the gray level range where the transition between lesion and background

  14. Double contrast-enhanced ultrasonography in the detection of periampullary cancer: Comparison with B-mode ultrasonography and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Ting [Department of Medical Image Center, Zhujiang Hospital, Southern Medical University, Guangzhou (China); Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Su, Zhong-zhen; Wang, Ping; Wu, Tao [Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Tang, Wen [Department of Radiology, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Xu, Er-jiao; Ju, Jin-xiu [Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Quan, Xian-yue, E-mail: quanxianyue2014@163.com [Department of Medical Image Center, Zhujiang Hospital, Southern Medical University, Guangzhou (China); Zheng, Rong-qin, E-mail: zhengrq@mail.sysu.edu.cn [Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China)

    2016-11-15

    Purpose: To investigate the value of double contrast-enhanced ultrasonography (DCEUS) in the detection of periampullary cancer. Materials and methods: Ninety-nine patients with surgery or biopsy-proven periampullary cancer who underwent both DCEUS and magnetic resonance imaging (MRI) examinations before operation were enrolled in our study. DCEUS in which intravenous microbubbles were used in combination with oral contrast agent and MRI were performed preoperatively to make a detection diagnosis of periampullary cancer. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of DCEUS, B-mode ultrasonography (BUS) and MRI were calculated and compared. Receiver operating characteristic (ROC) curves were used to evaluate the accuracy of BUS, DCEUS and MRI in the detection. Stratified analyses were performed for different pathological types and different sizes of periampullary lesions. The inter- and intra-observer reliability of DCEUS for cancer detection was also investigated. Result: There were no significant differences in sensitivity, specificity, PPV, NPV or accuracy between DCEUS and MRI (all P > 0.05). ROC analysis showed that the accuracy of DCEUS or MRI was higher than that of BUS (P < 0.001), while no significant differences were noted in the accuracy between DCEUS and MR. In the 76 cases of periampullary cancer, DCEUS appeared to be superior to BUS for ampullary carcinoma, duodenum carcinoma and for lesions with an average diameter of less than 3 cm. DCEUS appeared equal to BUS in other groups. No significant differences were noted between DCEUS and MRI in the stratified analysis. A considerably well agreement between DCEUS and MRI was obtained using Kappa analysis (k = 0.649, P < 0.001). The intra- and inter-observer reproducibility were both good for detection of periampullary cancer by DCEUS, with a Kappa values of 0.783 (P < 0.01) and 0.732 (P < 0.01), respectively. Conclusion: DCEUS provides an

  15. Usefulness of real-time three-dimensional ultrasonography in percutaneous nephrostomy: an animal study.

    Science.gov (United States)

    Hongzhang, Hong; Xiaojuan, Qin; Shengwei, Zhang; Feixiang, Xiang; Yujie, Xu; Haibing, Xiao; Gallina, Kazobinka; Wen, Ju; Fuqing, Zeng; Xiaoping, Zhang; Mingyue, Ding; Huageng, Liang; Xuming, Zhang

    2018-05-17

    To evaluate the effect of real-time three-dimensional (3D) ultrasonography (US) in guiding percutaneous nephrostomy (PCN). A hydronephrosis model was devised in which the ureters of 16 beagles were obstructed. The beagles were divided equally into groups 1 and 2. In group 1, the PCN was performed using real-time 3D US guidance, while in group 2 the PCN was guided using two-dimensional (2D) US. Visualization of the needle tract, length of puncture time and number of puncture times were recorded for the two groups. In group 1, score for visualization of the needle tract, length of puncture time and number of puncture times were 3, 7.3 ± 3.1 s and one time, respectively. In group 2, the respective results were 1.4 ± 0.5, 21.4 ± 5.8 s and 2.1 ± 0.6 times. The visualization of needle tract in group 1 was superior to that in group 2, and length of puncture time and number of puncture times were both lower in group 1 than in group 2. Real-time 3D US-guided PCN is superior to 2D US-guided PCN in terms of visualization of needle tract and the targeted pelvicalyceal system, leading to quick puncture. Real-time 3D US-guided puncture of the kidney holds great promise for clinical implementation in PCN. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  16. Pretreatment Evaluation with Contrast-Enhanced Ultrasonography for Percutaneous Radiofrequency Ablation of Hepatocellular Carcinomas with Poor Conspicuity on Conventional Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Ah Yeong; Lee, Min Woo; Rhim, Hyunchul; Cha, Dong Ik; Choi, Dongil; Kim, Young-sun; Lim, Hyo Keun; Cho, Seong Whi

    2013-01-01

    To determine whether pretreatment evaluation with contrast-enhanced ultrasonography (CEUS) is effective for percutaneous radiofrequency ablation (RFA) of hepatocellular carcinoma (HCC) with poor conspicuity on conventional ultrasonography (US). This retrospective study was approved by the institutional review board and informed consent was waived. From June 2008 to July 2011, 82 patients having HCCs (1.2 ± 0.4 cm) with poor conspicuity on planning US for RFA were evaluated with CEUS prior to percutaneous RFA. We analyzed our database, radiologic reports, and US images in order to determine whether the location of HCC candidates on planning US coincide with that on CEUS. To avoid incomplete ablation, percutaneous RFA was performed only when HCC nodules were identified on CEUS. The rate of technical success was assessed. The cumulative rate of local tumor progression was estimated with the use of the Kaplan-Meier method (mean follow-up: 24.0 ± 13.0 months). Among 82 patients, 73 (89%) HCCs were identified on CEUS, whereas 9 (11%) were not. Of 73 identifiable HCCs on CEUS, the location of HCC on planning US corresponded with that on CEUS in 64 (87.7%), whereas the location did not correspond in 9 (12.3%) HCCs. Technical success was achieved for all 73 identifiable HCCs on CEUS in a single (n = 72) or two (n = 1) RFA sessions. Cumulative rates of local tumor progression were estimated as 1.9% and 15.4% at 1 and 3 years, respectively. Pretreatment evaluation with CEUS is effective for percutaneous RFA of HCCs with poor conspicuity on conventional US

  17. Intraoperative contrast-enhanced ultrasonography for microcirculatory evaluation in rhesus monkey with spinal cord injury.

    Science.gov (United States)

    Huang, Lin; Chen, Keng; Chen, Fu-Chao; Shen, Hui-Yong; Ye, Ji-Chao; Cai, Zhao-Peng; Lin, Xi

    2017-06-20

    This study tried to quantify spinal cord perfusion by using contrast-enhanced ultrasound (CEUS) in rhesus monkey models with acute spinal cord injury. Acute spinal cord perfusion after injury was detected by CEUS, coupling with conventional ultrasound (US) and Color Doppler US (CDFI). Time-intensity curves and perfusion parameters were obtained by autotracking contrast quantification (ACQ) software in the epicenter and adjacent regions of injury, respectively. Neurological and histological examinations were performed to confirm the severity of injury. US revealed spinal cords were hypoechoic and homogeneous, whereas dura maters, pia maters, and cerebral aqueducts were hyperechoic. After spinal cord contusion, the injured spinal cord was hyperechoic on US, and intramedullary vessels of adjacent region of injury were increased and dilated on CDFI. On CEUS hypoperfusion were found in the epicenter of injury, while hyperperfusion in its adjacent region. Quantitative analysis showed that peak intensity (PI) decreased in epicenters of injury but significantly increased in adjacent regions at all time points (p spinal cord injury in overall views and real-time.

  18. Contrast enhanced ultrasound in liver imaging

    International Nuclear Information System (INIS)

    Nielsen, Michael Bachmann; Bang, Nanna

    2004-01-01

    Ultrasound contrast agents were originally introduced to enhance the Doppler signals when detecting vessels with low velocity flow or when imaging conditions were sub-optimal. Contrast agents showed additional properties, it was discovered that a parenchymal enhancement phase in the liver followed the enhancement of the blood pool. Contrast agents have made ultrasound scanning more accurate in detection and characterization of focal hepatic lesions and the sensitivity is now comparable with CT and MRI scanning. Further, analysis of the transit time of contrast agent through the liver seems to give information on possible hepatic involvement, not only from focal lesions but also from diffuse benign parenchymal disease. The first ultrasound contrast agents were easily destroyed by the energy from the sound waves but newer agents have proved to last for longer time and hereby enable real-time scanning and make contrast enhancement suitable for interventional procedures such as biopsies and tissue ablation. Also, in monitoring the effect of tumour treatment contrast agents have been useful. A brief overview is given on some possible applications and on different techniques using ultrasound contrast agents in liver imaging. At present, the use of an ultrasound contrast agent that allows real-time scanning with low mechanical index is to be preferred

  19. Therapeutic response assessment of high intensity focused ultrasound therapy for uterine fibroid: Utility of contrast-enhanced ultrasonography

    International Nuclear Information System (INIS)

    Zhou Xiaodong; Ren Xiaolong; Zhang Jun; He Guangbin; Zheng Minjuan; Tian Xue; Li Li; Zhu Ting; Zhang Min; Wang Lei; Luo Wen

    2007-01-01

    Purpose: To assess the utility of contrast-enhanced ultrasonography (ceUS) in the assessment of the therapeutic response to high intensity focused ultrasound (HIFU) ablation in patients with uterine fibroid. Materials and methods: Sixty-four patients with a total of 64 uterine fibroids (mean: 5.3 ± 1.2 cm; range: 3.2-8.9 cm) treated with HIFU ablation under the ultrasound guidance were evaluated with ceUS after receiving an intravenous bolus injection of a microbubble contrast agent (SonoVue) within 1 week after intervention. We obtained serial ceUS images during the time period from beginning to 5 min after the initiation of the bolus contrast injection. All of the patients underwent a contrast enhanced MRI (ceMRI) and ultrasound guided needle puncture biopsy within 1 week after HIFU ablation. And as a follow-up, all of the patients underwent US at 1, 3, 6 and 12 months after HIFU treatment. The volume change was observed and compared to pre- and post-HIFU ablation. The results of the ceUS were compared with those of the ceMRI in terms of the presence or absence of residual unablated tumor and pathologic change in the treated lesions. Results: On ceUS, diagnostic accuracy was 100%, while residual unablated tumors were found in three uterine fibroids (4.7%) and failed treatment was found in eight uterine fibroids (12.5%). All the 11 fibroids were subjected to additional HIFU ablation. Of the 58 ablated fibroids without residual tumors on both the ceUS and ceMRI after the HIFU ablation, the volumes of all the fibroids decreased in different degrees during the 1 year follow-up USs. And histologic examinations confirmed findings of necrotic and viable tumor tissue, respectively. Conclusion: CEUS is potentially useful for evaluating the early therapeutic effect of percutaneous HIFU ablation for uterine fibroids

  20. Evaluation of real time ultrasonography of the normal pancreas

    International Nuclear Information System (INIS)

    Kim, H. K.; Ko, Y. T.; Kim, S. Y.; Ahn, C. Y.

    1981-01-01

    91 cases who were free of pancreatic disease and the related conditions, were studied by high resolution and wide field real time ultrasonographic scanner with 3.5 MHz linear array electronically focusing transducers. The pancreatic examination method and the anatomic structures in and around the pancreas were investigated, and the normal pancreatic findings by real time ultrasonography were as follows: 1. Among all 91 cases, 44 cases were male and 47 cases female, and the frequent age groups were the 4th to the sixth decade. 2. The pancreatic images were obtained in 86% and the good images in 65%. 3. The shapes of pancreas were sausage (40%), dumb-bell (34%), tadpole (9%), and club (17%). 4. Pancreatic size was 1.56 ± 0.37, 2.4, 0.8 cm (Mean ± SD, Max., Min.) in head, 1.32 ± 0.29, 2.0, 0.8 cm in isthmus, and 1.62 ± 0.31, 2.4, 1.0 cm in tail. 5. The successful rate of pancreatic duct visualization was 46%. The shapes of pancreatic duct were linear (22%), tramline (16%), and tubular (8%). 6. The pancreatic echogenecity is greater than that of the liver in 68%, and equivalent to that of the liver in 32%, and no normal pancreas displayed less echogenecity than the liver. 7. Pancreatic echogenecity is lesser than that of adjacent soft tissue in 79% and equivalent to that of adjacent soft tissue in 21%. 8. The pancreatic echogenecity is homogenous in 79%. 9. The pancreatic margin is smooth in 62%, undulated in 11%, and ill defined in 27%

  1. Colour Doppler and microbubble contrast agent ultrasonography do not improve cancer detection rate in transrectal systematic prostate biopsy sampling.

    Science.gov (United States)

    Taverna, Gianluigi; Morandi, Giovanni; Seveso, Mauro; Giusti, Guido; Benetti, Alessio; Colombo, Piergiuseppe; Minuti, Francesco; Grizzi, Fabio; Graziotti, Pierpaolo

    2011-12-01

    What's known on the subject? and What does the study add? Transrectal gray-scale ultrasonography guided prostate biopsy sampling is the method for diagnosing prostate cancer (PC) in patients with an increased prostate specific antigen level and/or abnormal digital rectal examination. Several imaging strategies have been proposed to optimize the diagnostic value of biopsy sampling, although at the first biopsy nearly 10-30% of PC still remains undiagnosed. This study compares the PC detection rate when employing Colour Doppler ultransongraphy with or without the injection of SonoVue™ microbubble contrast agent, versus the transrectal ultrasongraphy-guided systematic biopsy sampling. The limited accuracy, sensitivity, specificity and the additional cost of using the contrast agent do not justify its routine application in PC detection. • To compare prostate cancer (PC) detection rate employing colour Doppler ultrasonography with or without SonoVue™ contrast agent with transrectal ultrasonography-guided systematic biopsy sampling. • A total of 300 patients with negative digital rectal examination and transrectal grey-scale ultrasonography, with PSA values ranging between 2.5 and 9.9 ng/mL, were randomized into three groups: 100 patients (group A) underwent transrectal ultrasonography-guided systematic bioptic sampling; 100 patients (group B) underwent colour Doppler ultrasonography, and 100 patients (group C) underwent colour Doppler ultrasonography before and during the injection of SonoVue™. • Contrast-enhanced targeted biopsies were sampled into hypervascularized areas of peripheral, transitional, apical or anterior prostate zones. • All the patients included in Groups B and C underwent a further 13 systematic prostate biopsies. The cancer detection rate was calculated for each group. • In 88 (29.3%) patients a histological diagnosis of PC was made, whereas 22 (7.4%) patients were diagnosed with high-grade prostatic intraepithelial

  2. Non-real-time computed tomography-guided percutaneous ethanol injection therapy for heapocellular carcinoma undetectable by ultrasonography

    International Nuclear Information System (INIS)

    Ueda, Kazushige; Ohkawara, Tohru; Minami, Masahito; Sawa, Yoshihiko; Morinaga, Osamu; Kohli, Yoshihiro; Ohkawara, Yasuo

    1998-01-01

    The purpose of this study was to evaluate the feasibility of non-real-time CT-guided percutaneous ethanol injection therapy (PEIT) for hepatocellular carcinoma (HCC, 37 lesions) untreatable by ultrasonography-guided (US)-PEIT. The HCC lesion was localized on the lipiodol CT image with a graduated grid system. We advanced a 21 G or 22 G needle in a stepwise fashion with intermittent localization scans using a tandem method to position the tip of the needle in the lesion. Ethanol containing contrast medium was injected with monitoring scans obtained after incremental volumes of injection, until perfusion of the lesion was judged to be complete. A total of 44 CT-PEIT procedures were performed. The average number of needle passes from the skin to the liver in each CT-PEIT procedure was 2.3, the average amount of ethanol injected was 14.4 ml, and the average time required was 49.3 minutes. Complete perfusion of the lesion by ethanol on monitoring CT images was achieved in all lesions with only a single or double CT-PEIT procedure without severe complication. Local recurrence was detected only in 5 lesions. At present, it is more time-consuming to perform CT-PEIT than US-PEIT because conventional CT guidance is not real-time imaging. However, it is expected that this limitation of CT-PEIT will be overcome in the near future with the introduction of CT fluoroscopy. In conclusion, CT-PEIT should prove to be a feasible, acceptable treatment for challenging cases of HCC undetectable by US. (author)

  3. Ultrasonography and contrast-enhanced CT findings of tularemia in the neck.

    Science.gov (United States)

    Doğan, Serap; Ekinci, Afra; Demiraslan, Hayati; Ulu Kılıç, Ayşegül; Mavili, Ertuğrul; Öztürk, Mustafa; İmamoğlu, Hakan; Doğanay, Mehmet

    2016-01-01

    We aimed to evaluate the ultrasonography (US) and contrast-enhanced computed tomography (CECT) findings of tularemia in the neck. US and CECT findings of 58 patients with serologically proven tularemia were retrospectively evaluated. Forty-eight patients underwent US and 42 patients underwent CECT. Lymph node characteristics and parotid preauricular region involvement were analyzed using US and CECT. In addition, involvement of larynx, oropharynx, and retropharynx; presence of periorbital edema; and neck abscess formation were evaluated using CECT. Fine needle aspiration cytology (FNAC) results of enlarged lymph nodes were analyzed in 29 patients. Hypoechoic pattern, round shape, absence of hilum, and cystic necrosis were seen in most of the lymph nodes especially at level 2 and 3 on US and CECT. Matting was more commonly observed than irregular nodal border on US and CECT. Parotid preauricular region involvement was seen in 20.8% of patients on US. Oropharyngeal, retropharyngeal, laryngeal and parotid preauricular region involvement and periorbital edema were seen in 52.4%, 19.1%, 4.8%, 31%, and 9.5% of tularemia patients, respectively. Neck abscess was found in 59.5% of patients on CECT. Suppurative inflammation was the most common finding of FNAC. Tularemia should be considered in the presence of level 2 and 3 lymph nodes with cystic necrosis, matting, absence of calcification, oropharyngeal and retropharyngeal region involvement, and neck abscess, particularly in endemic areas.

  4. The value and limitations of contrast-enhanced transrectal ultrasonography for the detection of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Han-Xue, E-mail: zhaohx861@163.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Xia, Chun-Xia, E-mail: star9901482@163.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Yin, Hong-Xia, E-mail: hongxia_yin79@yahoo.com.cn [Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Guo, Ning, E-mail: ningguo99@sina.com.cn [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Zhu, Qiang, E-mail: qzhutrhos@gmail.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China)

    2013-11-01

    Objectives: To evaluate the role of contrast-enhanced transrectal ultrasonography (CE-TRUS) for detecting prostate carcinoma. Methods: Sixty-five patients with elevated serum prostate-specific antigen (PSA) and/or abnormal digital rectal examination (DRE) were assessed using transrectal ultrasound (TRUS) and CE-TRUS. In all the patients, CE-TRUS was performed with intravenous injection of contrast agent (SonoVue, 2.4 ml) before biopsy. The cancer detection rates of the two techniques were compared. False-positive and false-negative findings related to CE-TRUS were analyzed in comparison to the pathological results of biopsy or radical prostatectomy. The targeted biopsy to abnormal CE-TRUS areas was also compared to systematic biopsy. Results: Prostate cancer was detected in 29 of the 65 patients. CE-TRUS showed rapid focal enhancement or asymmetric vessels of peripheral zones in 28 patients; 23 of them had prostate cancer. CE-TRUS had 79.3% sensitivity, compared to 65.5% of TRUS (P < 0.05). There were five false-positive and six false-negative findings from CE-TRUS. Benign prostate hyperplasia, and acute and chronic prostatitis were important causes related to the false-positive results of CE-TRUS. Prostate cancer originating from the transition zone or peripheral zone with lower PSA levels, small-size foci, and moderately or well-differentiated tumor was missed by CE-TRUS. The cancer detection rate of targeted biopsy (75%, 33/44 cores) was significantly higher than one of systematic biopsy (48.2%, 162/336) in those 28 cases (P < 0.05). In addition, no significant correlation was found between the cancer detection rate with CE-TRUS and serum PSA levels. Conclusion: CE-TRUS may improve the detection rate of prostate cancer through targeted biopsy of contrast-enhanced abnormalities. Our findings indicate that systematic biopsies should not be eliminated on the basis of false-positive and false-negative findings related to CE-TRUS.

  5. Real-time contrast imaging: a new method to monitor capillary recruitment in human forearm skeletal muscle.

    NARCIS (Netherlands)

    Mulder, A.H.; Dijk, A.P.J. van; Smits, P.; Tack, C.J.J.

    2008-01-01

    OBJECTIVE: Muscle capillary perfusion can be measured by contrast-enhanced ultrasound. We examined whether a less time-consuming ultrasound technique, called "real-time imaging," could be used to measure capillary recruitment in human forearm skeletal muscle. METHODS: We measured microvascular blood

  6. Therapeutic evaluation of sorafenib for hepatocellular carcinoma using contrast-enhanced ultrasonography: Preliminary result.

    Science.gov (United States)

    Shiozawa, Kazue; Watanabe, Manabu; Ikehara, Takashi; Kogame, Michio; Kikuchi, Yoshinori; Igarashi, Yoshinori; Sumino, Yasukiyo

    2016-07-01

    The present study aimed to determine the usefulness of contrast-enhanced ultrasonography (CEUS) with Sonazoid in evaluating the therapeutic response to sorafenib for hepatocellular carcinoma (HCC). In total, 26 patients with advanced HCC who received sorafenib and were followed up by CEUS were enrolled in the present study. CEUS was performed prior to and within 2-4 weeks of treatment, and the images of the target lesion in the post-vascular phase with a re-injection method were analyzed. The presence (+) or absence (-) of intratumoral necrosis and the intratumoral vascular architecture on micro-flow imaging (MFI) were compared prior to and subsequent to treatment. Target lesions that exhibited non-enhancement after re-injection were considered to indicate intratumoral necrosis. The intratumoral vascular architecture was classified into three groups, as follows: Vd, the intratumoral vessels visually narrowed or decreased; Vnc, the vessels remained unchanged; and Vi, the vessels were thickened or increased. Survival curves were estimated using the Kaplan-Meier method and compared using the log rank test between the intratumoral necrosis (+) and (-) groups, and among the Vd, Vnc and Vi groups. PVnc group and 5 patients in the Vi group. The MSTs in the Vd, Vnc and Vi groups were 15.6 months (95% CI, 5.0-23.3), 11.0 months (95% CI, 3.5-17.6) and 3.6 months (95% CI: 1.2-6.0), respectively. The P-value for the differences between the Vd and Vnc groups, Vd and Vi groups, and Vnc and Vi groups were 0.78, 0.016 and 0.047, respectively, which indicated that the survival time decreased significantly in the Vi group. Evaluation of intratumoral vascular architecture using MFI demonstrates promise for assessing the therapeutic response to sorafenib in patients with HCC.

  7. Differential diagnosis between intraductal papillary mucinous neoplasm with an associated invasive carcinoma and pancreatic ductal adenocarcinoma on ultrasonography: the utility of echo intensity and contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Masato [Dept. of Radiology, Sapporo Teishinkai Hospital, Sapporo (Japan); Hirokawa, Naoki; Usami, Yoko; Someya, Masanori; Sakata, Kohichi [Dept. of Radiology, Sapporo Medical University School of Medicine, Sapporo (Japan)

    2017-07-15

    The aim of this study was to investigate the utility of echo intensity and contrast enhancement in the differential diagnosis between intraductal papillary mucinous neoplasm with an associated invasive carcinoma (IPMN-IC) and pancreatic ductal adenocarcinoma (PDAC) on ultrasonography. This study included eight and 37 patients who had pathologically confirmed IPMN-IC and PDAC, respectively, and were enrolled for a comparative analysis of the sonographic features of the tumors. In the quantitative echo intensity evaluation, the two groups were compared with respect to the difference between the tumor intensity and the pancreatic intensity (TI-PI) and between the tumor intensity and the vascular intensity (TI-VI). In the quantitative contrast enhancement evaluation, the increase in echo intensity (ΔTI) and increase in echo intensity per unit of time (slope) were compared between the groups. The echo intensity and contrast enhancement were also compared between the two groups in patients with T3-T4 disease. In addition, the correlations of the histological type, tumor size, stromal type, and T factor with echogenicity and contrast enhancement were analyzed. IPMN-IC had significantly greater echo intensity and contrast enhancement than PDAC (TI-PI, P=0.004; TI-VI, P=0.001; ΔTI, P=0.012; slope, P=0.002). In T3-T4 disease, IPMN-IC also showed greater echo intensity and faster enhancement than PDAC. Echo intensity and contrast enhancement were correlated with histological type (TI-PI, P=0.003; TI-VI, P<0.001; ΔTI, P=0.007; slope, P<0.001). IPMN-IC and PDAC can be differentiated by the quantitative evaluation of echo intensity and contrast enhancement.

  8. Transrectal contrast-enhanced ultrasonography, transrectal ultrasonography and retrograde cystography for the detection of vesicourethral anastomosis leakage after radical retropubic prostatectomy: a prospective comparative evaluation.

    Science.gov (United States)

    Cantiello, Francesco; Cicione, Antonio; Autorino, Riccardo; De Nunzio, Cosimo; Tubaro, Andrea; Damiano, Rocco

    2013-01-01

    To evaluate the diagnostic accuracy of cystography (CG), transrectal ultrasonography (TRUS) and transrectal contrast-enhanced ultrasonography (CEUS) for the detection of vesicourethral extravasation (VE) after radical retropubic prostatectomy (RRP). In 80 consecutive patients who underwent RRP, the strength of the vesicourethral anastomosis (VUA) was assessed by CG, TRUS and transrectal CEUS. The investigation started with a conventional CG evaluated by an experienced uroradiologist. Following this, patients underwent TRUS which was performed by an experienced urologist who was blinded to the CG findings. The examination started with a conventional B-scan and, subsequently, a CEUS was performed by emptying and refilling the bladder with 90 ml of NaCl 0.9% + 10 ml suspension of 1:10 SonoVue and NaCl 0.9%. 26 patients (32.5%) presented urinary VE and 54 (67.5%) a watertight VUA. In 16 patients (61%) we observed a small leakage, 9 patients (35%) presented a moderate VE, and a large VE was detected in 1 patient (4%). No statistically significant difference in detection of VE was found among the three tests (p = 0.472). TRUS and CEUS are able to provide information about the integrity of the VUA that is comparable with that of CG. Copyright © 2013 S. Karger AG, Basel.

  9. Liver metastases: Sulphur hexafluoride-enhanced ultrasonography for lesion detection: a systematic review

    NARCIS (Netherlands)

    Cabassa, Paolo; Bipat, Shandra; Longaretti, Laura; Morone, Mario; Maroldi, Roberto

    2010-01-01

    This is a systematic review to evaluate the accuracy of contrast-enhanced ultrasonography (CEUS) performed with "SonoVue" (sulphur hexafluoride) in the detection of hepatic metastases. The MEDLINE, EMBASE and COCHRANE Databases were searched, regardless of language, for relevant articles published

  10. Contrast enhanced MRI findings of ductal carcinoma in situ

    International Nuclear Information System (INIS)

    Kang, Bong Joo; Cha, Eun Suk; Kim, Hyeon Sook; Suh, Young Jin; Choi, Hyun Joo

    2006-01-01

    The purpose of this study is to describe characteristic contrast enhanced MR mammographic findings of ductal carcinoma in situ (DCIS) and also DCIS with microinvasion. From January 2000 to July 2005, 32 women with 33 lesions affected by DCIS or DCIS with microinvasion underwent contrast enhanced MRI, and they were then retrospectively evaluated. All the patients had previously undergone mammography and ultrasonography. All the findings of mammography, ultrasonography (US), and MRI were analyzed by using an ACR BI-RADS lexicon. All 33 cases were enhanced on the enhanced MR images. A smooth margined homogeneous enhanced mass was seen in the two (2/33) cases, and nonmass enhancement was seen in 31 (31/33) cases. Among the non-mass enhancement, focal enhancement (7/31), ductal enhancement (5/31), segmental enhancement (9/31), and regional enhancement (10/31) were observed. On the kinetic study, a wash-out pattern (10/33), a plateau pattern (20/33), and a persistent pattern (3/33) were demonstrated. No significant differences were noted between the pure and microinvasive DCIS. There is no significant difference between pure and microinvasive DCIS. However, contrast enhanced MR images can demonstrate occult foci, multifocal lesion and the tumor extent of DCIS on mammogram or ultrasonogram

  11. Contrast enhanced MR findings of lesions associated with radial scar: correlation with histopathology

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Jee Woo; Cha, Eun Suk; Choi, Hyun Joo; Seo, Young Jin [College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of)

    2007-01-15

    To evaluate the contrast-enhanced MR findings of lesions associated with a radial scar and to compare the MR findings with the histopathology results. From Mar. 2001 to Sep. 2005, 8 patients with a surgically proven radial scar who had undergone MRI, mammography, and ultrasonography were enrolled in this study. The morphological findings and dynamic enhancement pattern of the time-intensity curve were retrospectively reviewed using noncontrast and contrast-enhanced MRI. Mammography and ultrasonography were also analyzed according to the BI-RADS category and correlated with the histopathological diagnosis. The age of the patients ranged from 42 to 53 years (mean, 47 years). Five patients presented with a left breast lesion and the others presented with a right breast lesion. The histopathological diagnosis associated with the radial scar were fibrocystic changes (n = 1) adenosis (n = 2), atypical ductal hyperplasia (n = 2), lobular carcinoma in situ (n = 1), ductal carcinoma in situ (n = 1), and invasive ductal carcinoma (n = 1). In all patients, architectural distortion without microcalcification was observed with mammography. Irregular shaped hypoechoic lesions with an indistinct, spiculated, or angular margin was observed in all patients with ultrasonography. Posterior shadowing was observed in 4 cases. MR enhancement revealed two cases with foci enhancement (adenosis and fibrocystic change), five cases with non-mass-like focal enhancement (fibrocystic change, atypical ductal hyperplasia, lobular carcinoma in situ, ductal carcinoma in situ, invasive ductal carcinoma), and one irregular homogeneous mass enhancement (atypical ducal hyperplasia). The time-signal intensity curves are as follows: persistent type (n = 2), adenosis, and fibrocystic changes, respectively; plateu type (n = 4) one adenosis, two atypical ductal hyperplasia, and one ductal carcinoma in situ; and washout type (n = 2), lobular carcinoma in situ, and invasive ductal carcinoma, respectively

  12. Contrast enhanced MR findings of lesions associated with radial scar: correlation with histopathology

    International Nuclear Information System (INIS)

    Chung, Jee Woo; Cha, Eun Suk; Choi, Hyun Joo; Seo, Young Jin

    2007-01-01

    To evaluate the contrast-enhanced MR findings of lesions associated with a radial scar and to compare the MR findings with the histopathology results. From Mar. 2001 to Sep. 2005, 8 patients with a surgically proven radial scar who had undergone MRI, mammography, and ultrasonography were enrolled in this study. The morphological findings and dynamic enhancement pattern of the time-intensity curve were retrospectively reviewed using noncontrast and contrast-enhanced MRI. Mammography and ultrasonography were also analyzed according to the BI-RADS category and correlated with the histopathological diagnosis. The age of the patients ranged from 42 to 53 years (mean, 47 years). Five patients presented with a left breast lesion and the others presented with a right breast lesion. The histopathological diagnosis associated with the radial scar were fibrocystic changes (n = 1) adenosis (n = 2), atypical ductal hyperplasia (n = 2), lobular carcinoma in situ (n = 1), ductal carcinoma in situ (n = 1), and invasive ductal carcinoma (n = 1). In all patients, architectural distortion without microcalcification was observed with mammography. Irregular shaped hypoechoic lesions with an indistinct, spiculated, or angular margin was observed in all patients with ultrasonography. Posterior shadowing was observed in 4 cases. MR enhancement revealed two cases with foci enhancement (adenosis and fibrocystic change), five cases with non-mass-like focal enhancement (fibrocystic change, atypical ductal hyperplasia, lobular carcinoma in situ, ductal carcinoma in situ, invasive ductal carcinoma), and one irregular homogeneous mass enhancement (atypical ducal hyperplasia). The time-signal intensity curves are as follows: persistent type (n = 2), adenosis, and fibrocystic changes, respectively; plateu type (n = 4) one adenosis, two atypical ductal hyperplasia, and one ductal carcinoma in situ; and washout type (n = 2), lobular carcinoma in situ, and invasive ductal carcinoma, respectively

  13. Detection of parenchymal abnormalities in experimentally induced acute pyelonephritis in rabbits using contrast-enhanced ultrasonography, CT, and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Ah; Kim, Bo Hyun; Kim, Seung Kwon; Seo, Jin Won [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Jong Sung [Laboratory Animal Research Center, Samsung Biomedical Research Institute, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-12-15

    We evaluated the efficacy of contrast-enhanced ultrasonography (CEUS) in detecting acute pyelonephritis (APN) using the rabbit kidney model and compared it with CT and MRI. This study was approved by the Institutional Review Board. In a total of 20 New Zealand White rabbits, APN was induced experimentally. CEUS, CT, and MRI were performed on the first, third, and seventh postoperative days. After imaging studies, the subjects were sacrificed and the pathological diagnosis of APN was confirmed in each animal by a pathologist. Imaging studies were obtained in eight animals, including eight CEUS, four computed tomography (CT), and four magnetic resonance imaging (MRI) images. CEUS depicted diffuse renal enlargement (7), diffuse heterogeneous parenchymal enhancement (6), and focal areas of decreased parenchymal enhancement (6). These findings were well correlated with the CT and MRI findings in five cases in which these studies were available. CT and MRI showed diffuse renal enlargement, diffuse heterogeneous parenchymal enhancement, focal areas of decreased parenchymal enhancement, focal contour bulging, and the finding of perinephric spread of infection. In a rabbit model, CEUS could depict the parenchymal lesions of APN similar to CT or MRI; however, it was limited in depicting the perinephric extension of inflammation.

  14. Evaluation of lymph node perfusion using continuous mode harmonic ultrasonography with a second-generation contrast agent.

    Science.gov (United States)

    Rubaltelli, Leopoldo; Khadivi, Yeganeh; Tregnaghi, Alberto; Stramare, Roberto; Ferro, Federica; Borsato, Simonetta; Fiocco, Ugo; Adami, Fausto; Rossi, Carlo Riccardo

    2004-06-01

    To evaluate the contribution of continuous mode contrast-enhanced harmonic ultrasonography (CE-HUS) with a second-generation contrast agent to the characterization of superficial lymphadenopathies with respect to conventional ultrasonographic techniques (B-mode and power Doppler). Fifty-six lymph nodes from 45 patients were studied both by conventional techniques and by CE-HUS. The dimensions, intranodal architecture, margins, and location of vessels were evaluated. Subsequently, all the lymph nodes were examined by CE-HUS, and enhancement of echogenicity was evaluated. The diagnoses obtained by means of fine-needle aspiration cytologic examination, surgical biopsy, or both were compared with those obtained by ultrasonography. Of the lymph nodes examined, 30 were benign and 26 were malignant (18 metastases and 8 non-Hodgkin lymphomas). The study using CE-HUS showed intense homogeneous enhancement in 28 of 30 reactive lymph nodes; perfusion defects in 17, of which 15 were neoplastic and 2 were inflammatory; intense but inhomogeneous speckled enhancement in the early arterial phase in 5 cases of lymphoma; and, last, scarce or absent intranodal enhancement in 4 metastases. The specificity, sensitivity, and accuracy of conventional techniques in differentiation between benign and malignant lymph nodes were 76%, 80%, and 78% versus 93%, 92%, and 92.8% for CE-HUS. The increase in correct diagnoses was significant (P = .05) when conventional ultrasonography was tested against CE-HUS. Superficial lymph nodes can be characterized as being neoplastic or benign with a high degree of diagnostic accuracy on the basis of the perfusion characteristics evaluated by CE-HUS. This technique has been shown to afford a higher degree of accuracy than currently obtainable by any other ultrasonographic technique.

  15. Can quantitative contrast-enhanced ultrasonography predict cervical tumor response to neoadjuvant chemotherapy?

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Chuan; Liu, Long-Zhong; Zheng, Wei [Department of Ultrasound, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou, 510060 (China); Xie, Yan-Jun [Department of Gynecology and Obstetrics, Zhongcun Town hospital, 140 Renmin Road, Zhongcun Town, Panyu District, Guangzhou, 511400 (China); Xiong, Yong-Hong; Li, An-Hua [Department of Ultrasound, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou, 510060 (China); Pei, Xiao-Qing, E-mail: peixq@sysucc.org.cn [Department of Ultrasound, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou, 510060 (China)

    2016-11-15

    Highlights: • We assessed the clinical value of quantitative CEUS for prediction of cervical tumor perfusion response to NACT. • IMAX, RT, and TTP changed significantly after one NACT cycle. • Pre-treatment IMAX positively correlated with the absolute and percentage changes in all cervical tumor IMAX after NACT. • Pre-treatment IMAX may be predictive of NACT perfusion response in cervical tumor. - Abstract: Objective: To evaluate the feasibility of quantitative contrast-enhanced ultrasonography (CEUS) for predicting and assessing cervical tumor response to neoadjuvant chemotherapy (NACT). Methods: Thirty-eight cases with stage IB2 or IIA cervical cancer were studied using CEUS before and after one cycle of NACT. The quantitative CEUS parameters maximum intensity (IMAX), rise time (RT), time to peak (TTP), and mean transit time (MTT) were compared between cervical tumors and myometrium (reference zone) using Sonoliver software. Absolute and relative changes in quantitative CEUS parameters were also compared among complete response, partial response, and non-responsive groups. Correlations between pre-treatment IMAX and changes in quantitative parameters were assessed after one cycle of NACT. Results: There were significant changes in cervical tumor IMAX (P < 0.001), RT (P < 0.05), and TTP (P < 0.05) after one cycle of NACT. According to the Response Evaluation Criteria In Solid Tumors guidelines, the enrollments were divided into complete response, partial response, stable disease and progressive disease groups. There were no significant differences in quantitative CEUS parameters among complete response, partial response, and non-responsive groups (P > 0.05). In the stable disease group (n = 17), cervical tumor IMAX, RT, and TTP decreased significantly after NACT (P < 0.001). The absolute and percentage changes in IMAX were positively correlated with pre-treatment IMAX in all 38 patients (r = 0.576, P < 0.001 and r = 0.429, P < 0.001). Conclusion

  16. A Case of Contiguous Primary Hepatic Marginal Zone B-Cell Lymphoma and Hemangioma Ultimately Diagnosed Using Contrast-Enhanced Ultrasonography

    Directory of Open Access Journals (Sweden)

    Kazue Shiozawa

    2015-02-01

    Full Text Available Primary hepatic marginal zone B-cell malignant lymphoma of mucosa-associated lymphoid tissue (MALT lymphoma is extremely rare. We present a case in which a lesion was diagnosed as 2 contiguous tumors (MALT lymphoma and hemangioma using contrast-enhanced ultrasonography (US with sonazoid. There has been no previous case of contiguous hepatic MALT lymphoma and hemangioma. The present case was a female with no medical history. We detected a snowman-like appearance, which was a tumor of 15 mm in diameter with hypo- and hyper-echogenicities in the lateral and medial parts, respectively, in the Couinaud's segment (S6 of the liver on US. The tumor appeared as a single lesion with a low-density area in the unenhanced phase and prolonged enhancement in the equilibrium phases on dynamic CT. On MRI, the whole lesion showed a low-intensity signal on T1-weighted imaging, but isointensity in the lateral part and high intensity in the medial part were seen on T2-weighted imaging. On contrast-enhanced US, the lateral hypoechoic region was homogenously hyperenhanced in the early vascular phase, and the contrast medium was washed out after about 30 s; in contrast, the medial hyperechoic region was gradually stained from the margin toward the central region. The tumor showed a defect in both hypo- and hyperechoic regions in the postvascular phase. Hemangioma was suspected for the medial part based on the typical image findings, but the lateral part was not given a diagnosis. Thus, surgical resection was performed. The medial part was a hemangioma, and the lateral part was a MALT lymphoma by histopathological findings.

  17. EFFECT OF SEDATION ON CONTRAST-ENHANCED ULTRASONOGRAPHY OF THE SPLEEN IN HEALTHY DOGS.

    Science.gov (United States)

    Rossi, Federica; Fina, Caroline; Stock, Emmelie; Vanderperren, Katrien; Duchateau, Luc; Saunders, Jimmy H

    2016-05-01

    Contrast-enhanced ultrasound of the spleen enables the dynamic assessment of the perfusion of this organ, however, both subjective and quantitative evaluation can be strongly influenced by sedative agent administration. The purpose of this prospective, experimental study was to test effects of two sedative agents on splenic perfusion during contrast-enhanced ultrasound of the spleen in a sample of healthy dogs. Contrast-enhanced ultrasound of the spleen was repeated in six healthy Beagles following a cross-over study design comparing three protocols: awake, butorphanol 0.2 mg/Kg intramuscular (IM), and dexmedetomidine 500 μg/m(2) IM. After intravenous injection of a phospholipid stabilized sulfur hexafluoride microbubble solution (SonoVue®, Bracco Imaging, Milano, Italy), the enhancement intensity and perfusion pattern of the splenic parenchyma were assessed and perfusion parameters were calculated. Normal spleen was slightly heterogeneous in the early phase, but the parenchyma was homogeneous at a later phase. Sedation with butorphanol did not modify perfusion of the spleen. Dexmedetomidine significantly reduced splenic enhancement, providing diffuse parenchymal hypoechogenicity during the entire examination. Measured parameters were significantly modified, with increased arrival time (AT; (dogs. Short-term and diffuse heterogeneity of the spleen in the early venous phase was determined to be a normal finding. © 2016 American College of Veterinary Radiology.

  18. Comparison of gray-scale contrast-enhanced ultrasonography with contrast-enhanced computed tomography in different grading of blunt hepatic and splenic trauma: an animal experiment.

    Science.gov (United States)

    Tang, Jie; Li, Wenxiu; Lv, Faqin; Zhang, Huiqin; Zhang, Lihai; Wang, Yuexiang; Li, Junlai; Yang, Li

    2009-04-01

    To compare the diagnostic value of contrast-enhanced ultrasonography (CEUS) with contrast-enhanced computed tomography (CECT) for the detection of different grading of solid organ injuries in blunt abdominal trauma in animals. A self-made miniature tools were used as models to simulate a blunt hepatic or splenic trauma in 16 and 14 anesthetized dogs, respectively. Baseline ultrasound, CEUS and CECT were used to detect traumatic injuries of livers and spleens. The degree of injuries was determined by CEUS according to the American Association for the Surgery of Trauma (AAST) scale and the results compared with injury scale based on CECT evaluation. CEUS showed 22 hepatic injury sites in 16 animals and 17 splenic injury sites in other 14 animals. According to AAST scale, 2 grade I, 4 grade II, 3 grade III, 5 grade IV and 2 grade V hepatic lesions were present in 16 animals; 2 grade I, 4 grade II, 6 grade III and 2 grade IV splenic lesions in 14 animals. On CECT scan, 21 hepatic and 17 splenic injuries were demonstrated. According to Becker CT scaling for hepatic injury, 1 grade I, 2 grade II, 4 grade III, 5 grade IV and 2 grade V hepatic injuries were present. On the basis of Buntain spleen scaling, 2 grade I, 5 grade II, 5 grade III, 2 grade IV splenic injuries were showed. After Spearman rank correlation analysis, the agreement of CEUS with CECT on the degree of hepatic and splenic injury is 93.3% and 92.9%, respectively. CT is currently considered as the reference method for grading blunt abdominal trauma, according to experiment results, CEUS grading showed high levels of concordance with CECT. CEUS can accurately determine the degree of injury and will play an important role in clinical application.

  19. Evaluation of pathological features of hepatocellular carcinoma by contrast-enhanced ultrasonography: Comparison with pathology on resected specimen

    International Nuclear Information System (INIS)

    Ogawa, Sadanobu; Kumada, Takashi; Toyoda, Hidenori; Ichikawa, Hideo; Kawachi, Toshiaki; Otobe, Katsuhiko; Hibi, Toshio; Takeshima, Kenji; Kiriyama, Seiki; Sone, Yasuhiro; Tanikawa, Makoto; Hisanaga, Yasuhiro; Yamaguchi, Akihiro; Isogai, Masatoshi; Kaneoka, Yuji; Washizu, Junji

    2006-01-01

    Features of hepatocellular carcinoma (HCC) observed by contrast-enhanced ultrasonography (CEUS) were compared to pathological features of corresponding resected HCC specimens, to evaluate the ability of CEUS to depict the pathological features of HCC. We investigated 50 HCC nodules that were treated by surgical resection. All nodules had been examined by CEUS with intravenous contrast agent (Levovist) before surgery. CEUS findings were divided into three phases for evaluation and classification of enhancement patterns: two vascular phases (arterial phase and portal venous phase) and the delayed phase. Pathological examination focused on differentiation and on the presence or absence of a tumor capsule, intratumoral septum, and intratumoral necrosis. All 21 nodules that showed a linear or annular vessel around the tumor margin in the arterial phase had capsular formation. Of the 27 nodules that showed heterogeneous perfusion in the portal venous phase, 21 (77.8%) had an intratumoral septum and 23 (85.2%) showed intratumoral necrosis. All nodules that were depicted as a defect with an unclear margin in the delayed phase were well-differentiated HCCs, whereas all nodules that were depicted as a defect with a clear margin were moderately or poorly differentiated HCCs. From our observations, the arterial, portal venous, and delayed phases of CEUS could reflect different pathological aspects of HCC. Some pathological characteristics of HCC might be evaluated preoperatively and non-invasively, by means of combined analysis of three phases of CEUS findings

  20. Imaging in hematology. Part 1: Ultrasonography and conventional radiology

    International Nuclear Information System (INIS)

    Zhechev, Y.

    2003-01-01

    Applications of conventional ultrasonography techniques (B-mode or real time) in oncohematology are presented. The newer adaptations (in particular colour Doppler) provide incremental advantages that support their inclusion in the imaging techniques available to modern hematology. Conventional radiologic studies include chest and bone X-ray, gastrointestinal contrast examination and bipedal lymphangiography

  1. Evaluation of liver parenchyma and perfusion using dynamic contrast-enhanced computed tomography and contrast-enhanced ultrasonography in captive green iguanas (Iguana iguana) under general anesthesia.

    Science.gov (United States)

    Nardini, Giordano; Di Girolamo, Nicola; Leopardi, Stefania; Paganelli, Irene; Zaghini, Anna; Origgi, Francesco C; Vignoli, Massimo

    2014-05-13

    Contrast-enhanced diagnostic imaging techniques are considered useful in veterinary and human medicine to evaluate liver perfusion and focal hepatic lesions. Although hepatic diseases are a common occurrence in reptile medicine, there is no reference to the use of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) to evaluate the liver in lizards. Therefore, the aim of this study was to evaluate the pattern of change in echogenicity and attenuation of the liver in green iguanas (Iguana iguana) after administration of specific contrast media. An increase in liver echogenicity and density was evident during CEUS and CECT, respectively. In CEUS, the mean ± SD (median; range) peak enhancement was 19.9% ± 7.5 (18.3; 11.7-34.6). Time to peak enhancement was 134.0 ± 125.1 (68.4; 59.6-364.5) seconds. During CECT, first visualization of the contrast medium was at 3.6 ± 0.5 (4; 3-4) seconds in the aorta, 10.7 ± 2.2 (10.5; 7-14) seconds in the hepatic arteries, and 15 ± 4.5 (14.5; 10-24) seconds in the liver parenchyma. Time to peak was 14.1 ± 3.4 (13; 11-21) and 31 ± 9.6 (29; 23-45) seconds in the aorta and the liver parenchyma, respectively. CEUS and dynamic CECT are practical means to determine liver hemodynamics in green iguanas. Distribution of contrast medium in iguana differed from mammals. Specific reference ranges of hepatic perfusion for diagnostic evaluation of the liver in iguanas are necessary since the use of mammalian references may lead the clinician to formulate incorrect diagnostic suspicions.

  2. Comparison of contrast media for visualization of the colon of healthy dogs during computed tomography and ultrasonography.

    Science.gov (United States)

    Cheon, Byunggyu; Moon, Sohyeon; Park, Seungjo; Lee, Sang-Kwon; Hong, Sunghwa; Cho, Hyun; Choi, Jihye

    2016-11-01

    OBJECTIVE To evaluate contrast agents for their ability to improve visualization of the colon wall and lumen during CT and ultrasonography. ANIMALS 10 healthy adult Beagles. PROCEDURES Food was withheld from dogs for 36 hours, after which dogs consumed 250 mL of polyethylene glycol solution. Dogs were then anesthetized, a contrast agent (tap water, diluted barium, or air; order randomly assigned) was administered rectally, iodine contrast medium (880 mg of I/kg) was administered IV, and CT and ultrasonography of the colon were performed. After a 1-week washout period, this process was repeated with a different contrast agent until all agents had been evaluated. Two investigators reviewed the CT and ultrasonographic images for colon wall thickness, conspicuity, artifacts, wall layering, and degree of lumen dilation at 4 sites. RESULTS Thickness of the colon wall was greatest in CT and ultrasonographic images with water used as contrast agent, followed by barium and then air. The CT images obtained after water administration had a smooth appearance that outlined the colonic mucosa and had the highest score of the 3 contrast agents for wall conspicuity. Although no substantial artifacts related to any of the contrast agents were identified on CT images, barium- and gas-induced shadowing and reverberation artifacts hindered wall evaluation during ultrasonography. For ultrasonography, the degree of conspicuity was highest with barium in the near-field wall and with water in the far-field wall. In contrast to CT, ultrasonography could be used to distinguish wall layering, and the mucosal and muscular layers were distinct with all contrast agents. CONCLUSIONS AND CLINICAL RELEVANCE Use of water as a contrast agent for both CT and ultrasonography of the colon in dogs compensated for each imaging modality's disadvantages and could be beneficial in the diagnosis of colon disease.

  3. Contrast-enhanced ultrasound and computed tomography findings of recurrent ovarian steroid cell tumor presenting with peritoneal seeding: A case report

    International Nuclear Information System (INIS)

    Im, A Lan; Lee, Young Hwan; Kim, Hye Won; Lee, Han Ah; Choi, Keum Ha

    2013-01-01

    We present ultrasonography and computed tomography (CT) findings of a case of recurrent ovarian steroid cell tumor presenting with peritoneal seeding in a 45-year-old woman. On abdominal ultrasonography, there were multiple hypoechoic round masses in the peritoneal cavity including the perihepatic area. Contrast-enhanced ultrasonography showed intense homogenous enhancement on the arterial phase and delayed prolonged enhancement of the masses. CT revealed multiple peritoneal solid masses with strong enhancement. Five years ago, the patient had been diagnosed with a steroid cell tumor of the left ovary. At that time, the CT showed a well-enhancing, lobulating, large solid mass at the left adnexa. Imaging findings of the peritoneal masses suggested peritoneal seeding from the preexisting ovarian steroid cell tumor. For treatment of the metastatic lesions in the perihepatic area, ultrasonography-guided radiofrequency ablation (RFA) was performed, and debulking surgery for the peritoneal masses was done. Six months later, complete ablation of the perihepatic metastases by RFA and a marked decrease in the peritoneal metastases by surgery were found on the follow-up CT.

  4. Real-time multiplexed digital cavity-enhanced spectroscopy

    International Nuclear Information System (INIS)

    Boyson, Toby K.; Dagdigian, Paul J.; Pavey, Karl D.; Fitzgerald, Nicholas J.; Spence, Thomas G.; Moore, David S.; Harb, Charles C.

    2015-01-01

    Cavity-enhanced spectroscopy is a sensitive optical absorption technique but one where the practical applications have been limited to studying small wavelength ranges. In addition, this Letter shows that wideband operation can be achieved by combining techniques usually reserved for the communications community with that of cavity-enhanced spectroscopy, producing a multiplexed real-time cavity-enhanced spectrometer. We use multiple collinear laser sources operating asynchronously and simultaneously while being detected on a single photodetector. This is synonymous with radio frequency (RF) cellular systems in which signals are detected on a single antenna but decoded uniquely. Here, we demonstrate results with spectra of methyl salicylate and show parts-per-billion per root hertz sensitivity measured in real-time

  5. Contrast-Enhanced Ultrasonography of Hepatocellular Carcinoma After Chemoembolisation Using Drug-Eluting Beads: A Pilot Study Focused on Sustained Tumor Necrosis

    International Nuclear Information System (INIS)

    Moschouris, Hippocrates; Malagari, Katerina; Papadaki, Marina Georgiou; Kornezos, Ioannis; Matsaidonis, Dimitrios

    2010-01-01

    The purpose of this study was to assess the use of contrast-enhanced ultrasonography (CEUS) and the sustained antitumor effect of drug-eluting beads used for transarterial chemoembolisation (TACE) of unresectable hepatocellular carcinoma (HCC). Ten patients with solitary, unresectable HCC underwent CEUS before, 2 days after, and 35 to 40 days after TACE using a standard dose (4 ml) of drug-eluting beads (DC Beads; Biocompatibles, Surrey, UK) preloaded with doxorubicin (25 mg doxorubicin/ml hydrated beads). For CEUS, a second-generation contrast agent (SonoVue, Bracco, Milan, Italy) and a low mechanical-index technique were used. A part of the tumor was characterized as necrotic if it showed complete lack of enhancement. The percentage of necrosis was calculated at the sonographic section that depicted the largest diameter of the tumor. Differences in the extent of early (2 days after TACE) and delayed (35 to 40 days after TACE) necrosis were quantitatively and subjectively assessed. Early post-TACE tumor necrosis ranged from 21% to 70% (mean 43.5% ± 19%). There was a statistically significant (p = 0.0012, paired Student t test) higher percentage of delayed tumor necrosis, which ranged from 24% to 88% (mean 52.3% ± 20.3%). Subjective evaluation showed a delayed obvious increase of the necrotic areas in 5 patients. In 2 patients, tumor vessels that initially remained patent disappeared on the delayed follow-up. A part of tumor necrosis after chemoembolisation of HCC with DEB seems to take place later than 2 days after TACE. CEUS may provide evidence for the sustained antitumor effect of DEB-TACE. Nevertheless, the ideal time for the imaging evaluation of tumor response remains to be defined.

  6. Contrast-Enhanced Ultrasonography in Differential Diagnosis of Benign and Malignant Ovarian Tumors

    Science.gov (United States)

    Qiao, Jing-Jing; Yu, Jing; Yu, Zhe; Li, Na; Song, Chen; Li, Man

    2015-01-01

    Objective To evaluate the accuracy of contrast-enhanced ultrasonography (CEUS) in differential diagnosis of benign and malignant ovarian tumors. Methods The scientific literature databases PubMed, Cochrane Library and CNKI were comprehensively searched for studies relevant to the use of CEUS technique for differential diagnosis of benign and malignant ovarian cancer. Pooled summary statistics for specificity (Spe), sensitivity (Sen), positive and negative likelihood ratios (LR+/LR−), and diagnostic odds ratio (DOR) and their 95%CIs were calculated. Software for statistical analysis included STATA version 12.0 (Stata Corp, College Station, TX, USA) and Meta-Disc version 1.4 (Universidad Complutense, Madrid, Spain). Results Following a stringent selection process, seven high quality clinical trials were found suitable for inclusion in the present meta-analysis. The 7 studies contained a combined total of 375 ovarian cancer patients (198 malignant and 177 benign). Statistical analysis revealed that CEUS was associated with the following performance measures in differential diagnosis of ovarian tumors: pooled Sen was 0.96 (95%CI = 0.92∼0.98); the summary Spe was 0.91 (95%CI = 0.86∼0.94); the pooled LR+ was 10.63 (95%CI = 6.59∼17.17); the pooled LR− was 0.04 (95%CI = 0.02∼0.09); and the pooled DOR was 241.04 (95% CI = 92.61∼627.37). The area under the SROC curve was 0.98 (95% CI = 0.20∼1.00). Lastly, publication bias was not detected (t = −0.52, P = 0.626) in the meta-analysis. Conclusions Our results revealed the high clinical value of CEUS in differential diagnosis of benign and malignant ovarian tumors. Further, CEUS may also prove to be useful in differential diagnosis at early stages of this disease. PMID:25764442

  7. Implementation of real-time duplex synthetic aperture ultrasonography

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Larsen, Lee; Kjeldsen, Thomas

    2015-01-01

    This paper presents a real-time duplex synthetic aperture imaging system, implemented on a commercially available tablet. This includes real-time wireless reception of ultrasound signals and GPU processing for B-mode and Color Flow Imaging (CFM). The objective of the work is to investigate the im...... and that the required bandwidth between the probe and processing unit is within the current Wi-Fi standards....

  8. Contrast-enhanced transrectal ultrasonography for the detection of diffuse prostate cancer

    International Nuclear Information System (INIS)

    Gao, Y.; Liao, X.H.; Lu, L.; Wang, L.; Ma, Y.; Qin, H.Z.; Yan, X.; Guo, P.

    2016-01-01

    Aim: To evaluate the diagnostic accuracy of contrast-enhanced transrectal ultrasonography (CE-TRUS) versus baseline TRUS (combination of grey-scale and colour Doppler imaging) for diffuse prostate cancer. Materials and methods: Forty-six patients without an obvious focal mass on baseline TRUS (grey-scale and colour Doppler), underwent additional CE-TRUS and TRUS-guided biopsy due to elevated levels of prostate-specific antigen (PSA ≥4 ng/ml) and/or abnormal digital rectal examination (DRE). In all patients, CE-TRUS was performed with intravenous injection of a contrast agent (sulphur hexafluoride microbubble; SonoVue, 2.4 ml) before biopsy. TRUS-guided biopsy targeted suspicious areas detected on CE-TRUS imaging or sampled the outer gland of the normal prostate. The final diagnosis was based on results of the TRUS-guided biopsy. The diagnostic accuracy of baseline TRUS and CE-TRUS for diffuse prostatic lesions was evaluated using receiver operating characteristic (ROC) curve analysis. Results: Diffuse prostate cancer was present in 32 (69.5%) patients and absent in 14 (30.5%) patients. Nineteen patients had diffuse prostate cancer that was not detected by baseline TRUS, whereas 15 cases were identified using CE-TRUS. Conversely, five patients had benign prostatic hypertrophy (BPH) that was diagnosed as cancer by CE-TRUS, and two of these patients were diagnosed with BPH by baseline TRUS. The combined sensitivity, specificity, and accuracy were 87.5%, 64.2%, and 80.4%, respectively, for CE-TRUS, and 40.6%, 78.5%, and 52.1%, respectively, for baseline TRUS. The area under the ROC curve (AUC) values for the diagnostic accuracy of baseline CE-TRUS versus TRUS for diffuse prostate cancer differed significantly at 0.904 and 0.667, respectively (Z=4.098, p<0.0001). Conclusion: CE-TRUS exhibited greater diagnostic accuracy for diffuse prostate cancer than baseline TRUS. CE-TRUS may improve cancer detection over baseline TRUS imaging for the diagnosis of diffuse

  9. Quantitative Differences Between the First and Second Injection of Contrast Agent in Contrast-Enhanced Ultrasonography of Feline Kidneys and Spleen.

    Science.gov (United States)

    Stock, Emmelie; Vanderperren, Katrien; Haers, Hendrik; Duchateau, Luc; Hesta, Myriam; Saunders, Jimmy H

    2017-02-01

    Contrast-enhanced ultrasound is a valuable and safe technique for the evaluation of organ perfusion. Repeated injections of ultrasound contrast agent are often administered during the same imaging session. However, it remains unclear if quantitative differences are present between the consecutive microbubble injections. Therefore, the first and second injection of contrast agent for the left renal cortex, renal medulla and the splenic parenchyma in healthy cats were compared. A lower peak intensity and area under the curve were observed for the first injection of contrast agent in the feline kidney, both for the renal cortex and medulla, and spleen. Moreover, for the renal cortex, the time-intensity curve was steeper after the second injection. Findings from the present study demonstrate that a second injection of contrast agent provides stronger enhancement. The exact mechanism behind our findings remains unclear; however, saturation of the lung macrophages is believed to play an important role. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. Ultrasonography of pediatric urogenital emergencies: review of classic and new techniques

    Directory of Open Access Journals (Sweden)

    Masahiro Kitami

    2017-07-01

    Full Text Available Urogenital emergencies are fairly common in the pediatric population, and a timely and correct diagnosis is necessary to avoid possible future infertility. In this field, ultrasonography is essential, as it has the advantages of being radiation-free and readily accessible. In particular, a high-frequency transducer allows precise evaluation of the morphology and vascularity of the scrotum, which is on the surface of the body. Beyond conventional techniques, new advanced imaging techniques have been developed, including elastography and contrast-enhanced ultrasonography. However, several pitfalls remain in the diagnosis of urogenital diseases using ultrasonography. Thus, accurate knowledge and sufficient experience with the technique are essential for making a correct diagnosis. This review provides an overview of pediatric urogenital emergency pathologies and recent ultrasonography techniques.

  11. Ultrasonography of pediatric urogenital emergencies: review of classic and new techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kitami, Masahiro [Dept. of Diagnostic Radiology, Tohoku University Graduate School of Medicine, Sendai (Japan)

    2017-07-15

    Urogenital emergencies are fairly common in the pediatric population, and a timely and correct diagnosis is necessary to avoid possible future infertility. In this field, ultrasonography is essential, as it has the advantages of being radiation-free and readily accessible. In particular, a high-frequency transducer allows precise evaluation of the morphology and vascularity of the scrotum, which is on the surface of the body. Beyond conventional techniques, new advanced imaging techniques have been developed, including elastography and contrast-enhanced ultrasonography. However, several pitfalls remain in the diagnosis of urogenital diseases using ultrasonography. Thus, accurate knowledge and sufficient experience with the technique are essential for making a correct diagnosis. This review provides an overview of pediatric urogenital emergency pathologies and recent ultrasonography techniques.

  12. Visual detectability of elastic contrast in real-time ultrasound images

    Science.gov (United States)

    Miller, Naomi R.; Bamber, Jeffery C.; Doyley, Marvin M.; Leach, Martin O.

    1997-04-01

    Elasticity imaging (EI) has recently been proposed as a technique for imaging the mechanical properties of soft tissue. However, dynamic features, known as compressibility and mobility, are already employed to distinguish between different tissue types in ultrasound breast examination. This method, which involves the subjective interpretation of tissue motion seen in real-time B-mode images during palpation, is hereafter referred to as differential motion imaging (DMI). The purpose of this study was to develop the methodology required to perform a series of perception experiments to measure elastic lesion detectability by means of DMI and to obtain preliminary results for elastic contrast thresholds for different lesion sizes. Simulated sequences of real-time B-scans of tissue moving in response to an applied force were generated. A two-alternative forced choice (2-AFC) experiment was conducted and the measured contrast thresholds were compared with published results for lesions detected by EI. Although the trained observer was found to be quite skilled at the task of differential motion perception, it would appear that lesion detectability is improved when motion information is detected by computer processing and converted to gray scale before presentation to the observer. In particular, for lesions containing fewer than eight speckle cells, a signal detection rate of 100% could not be achieved even when the elastic contrast was very high.

  13. Contrast-enhanced computed tomographic colonography in the follow-up of colorectal cancer patients: a feasibility study

    International Nuclear Information System (INIS)

    Laghi, Andrea; Iannaccone, Riccardo; Carbone, Iacopo; Piacentini, Francesca; Passariello, Roberto; Bria, Emilio; Trasatti, Luciana; Lauro, Salvatore; Vecchione, Aldo

    2003-01-01

    The aim of our study was to assess whether contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up program of colorectal cancer patients. Thirty-five patients, surgically treated for colorectal cancer, underwent a follow-up program that included physical examination, carcinoembryonic antigen serum assay, conventional colonoscopy, liver ultrasonography, and chest X-ray. For these patients, we added a yearly contrast-enhanced CT colonography. All CT examinations were performed with a high-resolution protocol using a multidetector spiral CT scanner (Siemens, Erlangen, Germany) prior to and after the administration of 130 ml of i.v. contrast material. Images were directly analyzed on a dedicated workstation by two radiologists to determine colonic evaluation, visualization of colonic anastomosis, presence of polyps, and extra-colonic findings. Colonic evaluation was judged as optimal in 91.7% of all colonic segments. All mechanical surgical anastomoses were visualized with CT colonography. There was no evidence of anastomotic recurrence. Seven polyps were detected in five different patients with CT colonography, with two false-positive and no false-negative examinations. Three liver metastases and two basal pulmonary nodules were also identified. Contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up of patients operated on for colorectal cancer. (orig.)

  14. The 'humble' bubble: Contrast-enhanced ultrasound

    International Nuclear Information System (INIS)

    Marshall, Gill; Sykes, Anne; Berry, Jonathan; Jonker, Leon

    2011-01-01

    The use of contrast-enhanced ultrasound (CEUS) is increasing within the field of medical imaging. Ultrasonic contrast agent (UCA) contain gas microbubbles similar in size to red corpuscles which provide highly reflective interfaces, enabling dynamic demonstration of echogenic streams of the contrast within the anatomical area of interest on real-time grey scale ultrasound. Longevity of the microbubbles has been improved by changing their composition. The application of CEUS in the UK continues to grow, bringing it into territories historically occupied by computerised tomography (CT) scanning and magnetic resonance imaging (MRI). Hence, the role of CEUS may be of interest to all diagnostic imaging practitioners. Here we summarise the mode of action and use of CEUS, and its role within a range of applications. The potential risks of CEUS are compared to other contrast-enhanced imaging techniques. The benefits of CEUS and its implications for diagnostic imaging practice are also covered.

  15. Centrifugal (inside-out) enhancement of liver hemangiomas: A possible atypical appearance on contrast-enhanced US

    International Nuclear Information System (INIS)

    Bartolotta, Tommaso Vincenzo; Taibbi, Adele; Galia, Massimo; Lo Re, Giuseppe; La Grutta, Ludovico; Grassi, Roberto; Midiri, Massimo

    2007-01-01

    Objective: To report the prevalence and to describe the atypical centrifugal (inside-out) appearance of contrast-enhancement of liver hemangiomas on contrast-enhanced sonography. Materials and methods: Baseline and SonoVue-enhanced ultrasonography of 92 patients with 158 liver hemangiomas - considered atypical at grey-scale examination and confirmed by computed tomography, magnetic resonance imaging and ultrasound follow-up - were reviewed in consensus by two experienced radiologists, who evaluated baseline echogenicity and the dynamic enhancement pattern of each lesion looking for the presence of central enhancing foci in the arterial phase followed by a centrifugal (inside-out) enhancement in the portal-venous and late phases. Results: After administration of SonoVue, 12/158 hemangiomas (7.6%) (size range: 1-7 cm; mean: 3.2 cm) in seven patients (5 women, 2 men; age range: 34-71 years, mean: 50.8 years) showed a central enhancing focus in the arterial phase followed by a centrifugal enhancement in the portal-venous and late phases. In all cases centrifugal enhancement was incomplete at contrast-enhanced sonography, whereas computed tomography and/or magnetic resonance imaging were able to depict a complete and homogeneous fill-in. Conclusion: Radiologist should be aware that centrifugal (inside-out) appearance on contrast-enhanced sonography is a rare but possible feature of liver hemangioma

  16. Centrifugal (inside-out) enhancement of liver hemangiomas: A possible atypical appearance on contrast-enhanced US

    Energy Technology Data Exchange (ETDEWEB)

    Bartolotta, Tommaso Vincenzo [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: tv.bartolotta@unipa.it; Taibbi, Adele [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: taibbi_adele@yahoo.it; Galia, Massimo [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: mgalia@yahoo.com; Lo Re, Giuseppe [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: giuseppe.lore12@tin.it; La Grutta, Ludovico [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: lagrutta@mbox.infcom.it; Grassi, Roberto [Institute of Radiology, Second University of Naples, Piazza Miraglia, 80138 Naples (Italy)], E-mail: roberto.grassi@libero.it; Midiri, Massimo [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: mmidiri@hotmail.com

    2007-12-15

    Objective: To report the prevalence and to describe the atypical centrifugal (inside-out) appearance of contrast-enhancement of liver hemangiomas on contrast-enhanced sonography. Materials and methods: Baseline and SonoVue-enhanced ultrasonography of 92 patients with 158 liver hemangiomas - considered atypical at grey-scale examination and confirmed by computed tomography, magnetic resonance imaging and ultrasound follow-up - were reviewed in consensus by two experienced radiologists, who evaluated baseline echogenicity and the dynamic enhancement pattern of each lesion looking for the presence of central enhancing foci in the arterial phase followed by a centrifugal (inside-out) enhancement in the portal-venous and late phases. Results: After administration of SonoVue, 12/158 hemangiomas (7.6%) (size range: 1-7 cm; mean: 3.2 cm) in seven patients (5 women, 2 men; age range: 34-71 years, mean: 50.8 years) showed a central enhancing focus in the arterial phase followed by a centrifugal enhancement in the portal-venous and late phases. In all cases centrifugal enhancement was incomplete at contrast-enhanced sonography, whereas computed tomography and/or magnetic resonance imaging were able to depict a complete and homogeneous fill-in. Conclusion: Radiologist should be aware that centrifugal (inside-out) appearance on contrast-enhanced sonography is a rare but possible feature of liver hemangioma.

  17. The role of contrast-enhanced endoscopic ultrasound in pancreatic adenocarcinoma

    DEFF Research Database (Denmark)

    Saftoiu, Adrian; Vilmann, Peter; Bhutani, Manoop S

    2016-01-01

    contrast agents for early detection, tridimensional and fusion techniques for enhanced staging and resectability assessment but also novel applications of perfusion imaging for monitoring ablative therapy, improved local detection through EUS-guided sampling of portal vein flow or enhanced drug delivery......Contrast-enhanced endoscopic ultrasound (CE-EUS) allows characterization, differentiation, and staging of focal pancreatic masses. The method has a high sensitivity and specificity for the diagnosis of pancreatic adenocarcinoma which is visualized as hypo-enhanced as compared to the rest...... of the parenchyma while chronic pancreatitis and neuroendocrine tumors are generally either iso-enhanced or hyper-enhanced. The development of contrast-enhanced low mechanical index harmonic imaging techniques used in real time during endoscopic ultrasound (EUS) allowed perfusion imaging and the quantification...

  18. Evaluation of hepatocellular carcinoma tumor vascularity using contrast-enhanced ultrasonography as a predictor for local recurrence following radiofrequency ablation

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Tomohiro [Gastroenterological Center, Yokohama City University Medical Center, 4-57 Urafune-cho, Minami-ku, Yokohama, Kanagawa 232-0024 (Japan); Numata, Kazushi, E-mail: kz-numa@urahp.yokohama-cu.ac.jp [Gastroenterological Center, Yokohama City University Medical Center, 4-57 Urafune-cho, Minami-ku, Yokohama, Kanagawa 232-0024 (Japan); Hao, Yoshiteru; Doba, Nobutaka; Hara, Koji [Gastroenterological Center, Yokohama City University Medical Center, 4-57 Urafune-cho, Minami-ku, Yokohama, Kanagawa 232-0024 (Japan); Kondo, Masaaki [Division of Gastroenterology, Yokohama City University Graduate School of Medicine, 3-9 Fukuura, Kanazawa-ku, Yokohama, Kanagawa 236-0004 (Japan); Tanaka, Katsuaki [Gastroenterological Center, Yokohama City University Medical Center, 4-57 Urafune-cho, Minami-ku, Yokohama, Kanagawa 232-0024 (Japan); Maeda, Shin [Division of Gastroenterology, Yokohama City University Graduate School of Medicine, 3-9 Fukuura, Kanazawa-ku, Yokohama, Kanagawa 236-0004 (Japan)

    2017-04-15

    Purpose: The purpose of this study was to evaluate whether the hypervascularity of hepatocellular carcinomas (HCCs) on contrast-enhanced ultrasonography (CEUS) prior to radiofrequency ablation (RFA) is a significant risk factor for local recurrence after RFA. Materials and methods: Institutional review board approval and informed consent were obtained. Overall, 208 patients (mean age, 71.7 years; range, 50–87 years; 137 men, 71 women) with 282 HCCs treated with RFA were analyzed retrospectively. The mean maximum tumor diameter was 15.7 mm. We compared the abilities of CEUS and contrast-enhanced computed tomography (CECT) to detect hypervascularity in HCCs. We then classified the HCCs into two groups according to the arterial-phase CEUS findings: a “hypervascular group” with whole or partial hypervascular areas within the lesions compared with the surrounding liver parenchyma, and a “non-hypervascular group” with isovascular or hypovascular areas within the lesions. We assessed the cumulative rate of local recurrence after RFA, and we also evaluated the risk factors for local recurrence using a univariate analysis. Results: The detection rate for hypervascular HCCs was significantly higher using CEUS (78%, 221/282) than that using CECT (66%, 186/282) (P < 0.001). Using the CEUS findings, the cumulative rate of local recurrence was significantly higher in the hypervascular group (41.2%, 56/221) than in the non-hypervascular group (18.4%, 6/61) (P = 0.007). A univariate analysis revealed that hypervascularity on CEUS was an independent risk factor for local recurrence (P = 0.010). Conclusion: Hypervascularity in HCCs as observed using CEUS is a significant risk factor for local recurrence after RFA.

  19. Ultrasonography in gastroenterology.

    Science.gov (United States)

    Ødegaard, Svein; Nesje, Lars B; Hausken, Trygve; Gilja, Odd Helge

    2015-06-01

    Ultrasonography (US) is a safe and available real-time, high-resolution imaging method, which during the last decades has been increasingly integrated as a clinical tool in gastroenterology. New US applications have emerged with enforced data software and new technical solutions, including strain evaluation, three-dimensional imaging and use of ultrasound contrast agents. Specific gastroenterologic applications have been developed by combining US with other diagnostic or therapeutic methods, such as endoscopy, manometry, puncture needles, diathermy and stents. US provides detailed structural information about visceral organs without hazard to the patients and can play an important clinical role by reducing the need for invasive procedures. This paper presents different aspects of US in gastroenterology, with a special emphasis on the contribution from Nordic scientists in developing clinical applications.

  20. Ultrasound contrast agent imaging: Real-time imaging of the superharmonics

    Energy Technology Data Exchange (ETDEWEB)

    Peruzzini, D.; Viti, J. [MSD lab, Department of Information Engineering, Univ of Florence, Via S.Marta, 3, 50139 Firenze (Italy); Erasmus MC, ’s-Gravendijkwal 230, Faculty Building, Ee 2302, 3015 CE Rotterdam (Netherlands); Tortoli, P. [MSD lab, Department of Information Engineering, Univ of Florence, Via S.Marta, 3, 50139 Firenze (Italy); Verweij, M. D. [Acoustical Wavefield Imaging, ImPhys, Delft Univ Technology, van der Waalsweg 8, 2628 CH Delft (Netherlands); Jong, N. de; Vos, H. J., E-mail: h.vos@erasmusmc.nl [Erasmus MC, ’s-Gravendijkwal 230, Faculty Building, Ee 2302, 3015 CE Rotterdam (Netherlands); Acoustical Wavefield Imaging, ImPhys, Delft Univ Technology, van der Waalsweg 8, 2628 CH Delft (Netherlands)

    2015-10-28

    Currently, in medical ultrasound contrast agent (UCA) imaging the second harmonic scattering of the microbubbles is regularly used. This scattering is in competition with the signal that is caused by nonlinear wave propagation in tissue. It was reported that UCA imaging based on the third or higher harmonics, i.e. “superharmonic” imaging, shows better contrast. However, the superharmonic scattering has a lower signal level compared to e.g. second harmonic signals. This study investigates the contrast-to-tissue ratio (CTR) and signal to noise ratio (SNR) of superharmonic UCA scattering in a tissue/vessel mimicking phantom using a real-time clinical scanner. Numerical simulations were performed to estimate the level of harmonics generated by the microbubbles. Data were acquired with a custom built dual-frequency cardiac phased array probe. Fundamental real-time images were produced while beam formed radiofrequency (RF) data was stored for further offline processing. The phantom consisted of a cavity filled with UCA surrounded by tissue mimicking material. The acoustic pressure in the cavity of the phantom was 110 kPa (MI = 0.11) ensuring non-destructivity of UCA. After processing of the acquired data from the phantom, the UCA-filled cavity could be clearly observed in the images, while tissue signals were suppressed at or below the noise floor. The measured CTR values were 36 dB, >38 dB, and >32 dB, for the second, third, and fourth harmonic respectively, which were in agreement with those reported earlier for preliminary contrast superharmonic imaging. The single frame SNR values (in which ‘signal’ denotes the signal level from the UCA area) were 23 dB, 18 dB, and 11 dB, respectively. This indicates that noise, and not the tissue signal, is the limiting factor for the UCA detection when using the superharmonics in nondestructive mode.

  1. Contrast enhancement of mail piece images

    Science.gov (United States)

    Shin, Yong-Chul; Sridhar, Ramalingam; Demjanenko, Victor; Palumbo, Paul W.; Hull, Jonathan J.

    1992-08-01

    A New approach to contrast enhancement of mail piece images is presented. The contrast enhancement is used as a preprocessing step in the real-time address block location (RT-ABL) system. The RT-ABL system processes a stream of mail piece images and locates destination address blocks. Most of the mail pieces (classified into letters) show high contrast between background and foreground. As an extreme case, however, the seasonal greeting cards usually use colored envelopes which results in reduced contrast osured by an error rate by using a linear distributed associative memory (DAM). The DAM is trained to recognize the spectra of three classes of images: with high, medium, and low OCR error rates. The DAM is not forced to make a classification every time. It is allowed to reject as unknown a spectrum presented that does not closely resemble any that has been stored in the DAM. The DAM was fairly accurate with noisy images but conservative (i.e., rejected several text images as unknowns) when there was little ground and foreground degradations without affecting the nondegraded images. This approach provides local enhancement which adapts to local features. In order to simplify the computation of A and (sigma) , dynamic programming technique is used. Implementation details, performance, and the results on test images are presented in this paper.

  2. Enhancement tuning and control for high dynamic range images in multi-scale locally adaptive contrast enhancement algorithms

    Science.gov (United States)

    Cvetkovic, Sascha D.; Schirris, Johan; de With, Peter H. N.

    2009-01-01

    For real-time imaging in surveillance applications, visibility of details is of primary importance to ensure customer confidence. If we display High Dynamic-Range (HDR) scenes whose contrast spans four or more orders of magnitude on a conventional monitor without additional processing, results are unacceptable. Compression of the dynamic range is therefore a compulsory part of any high-end video processing chain because standard monitors are inherently Low- Dynamic Range (LDR) devices with maximally two orders of display dynamic range. In real-time camera processing, many complex scenes are improved with local contrast enhancements, bringing details to the best possible visibility. In this paper, we show how a multi-scale high-frequency enhancement scheme, in which gain is a non-linear function of the detail energy, can be used for the dynamic range compression of HDR real-time video camera signals. We also show the connection of our enhancement scheme to the processing way of the Human Visual System (HVS). Our algorithm simultaneously controls perceived sharpness, ringing ("halo") artifacts (contrast) and noise, resulting in a good balance between visibility of details and non-disturbance of artifacts. The overall quality enhancement, suitable for both HDR and LDR scenes, is based on a careful selection of the filter types for the multi-band decomposition and a detailed analysis of the signal per frequency band.

  3. The optimization of scan timing for contrast-enhanced magnetic resonance angiography

    International Nuclear Information System (INIS)

    Lee, Jong Min; Chang, Yong Min; Ryeom, Hun Kyu; Lee, Sang Kwon; Kim, Yong Sun; Kang, Duk Sik; Tirman, Philip J.

    2000-01-01

    To determine the optimal scan timing for contrast-enhanced magnetic resonance angiography and to evaluate a new timing method based on the arteriovenous circulation time. Eighty-nine contrast-enhanced magnetic resonance angiographic examinations were performed mainly in the extremities. A 1.5T scanner with a 3-D turbo-FLASH sequence was used, and during each study, two consecutive arterial phases and one venous phase were acquired. Scan delay time was calculated from the time-intensity curve by the traditional (n = 48) and/or the new (n = 41) method. This latter was based on arteriovenous circulation time rather than peak arterial enhancement time, as used in the traditional method. The numbers of first-phase images showing a properly enhanced arterial phase were compared between the two methods. Mean scan delay time was 5.4 sec longer with the new method than with the traditional. Properly enhanced first-phase images were found in 65% of cases (31/48) using the traditional timing method, and 95% (39/41) using the new method. When cases in which there was mismatch between the target vessel and the Time-intensity curve acquisition site are excluded, erroneous acquisition occurred in seven cases with the traditional method, but in none with the new method. The calculation of scan delay time on the basis of arteriovenous circulation time provides better timing for arterial phase acquisition than the traditional method

  4. Real-time contrast ultrasound muscle perfusion imaging with intermediate-power imaging coupled with acoustically durable microbubbles.

    Science.gov (United States)

    Seol, Sang-Hoon; Davidson, Brian P; Belcik, J Todd; Mott, Brian H; Goodman, Reid M; Ammi, Azzdine; Lindner, Jonathan R

    2015-06-01

    There is growing interest in limb contrast-enhanced ultrasound (CEU) perfusion imaging for the evaluation of peripheral artery disease. Because of low resting microvascular blood flow in skeletal muscle, signal enhancement during limb CEU is prohibitively low for real-time imaging. The aim of this study was to test the hypothesis that this obstacle can be overcome by intermediate- rather than low-power CEU when performed with an acoustically resilient microbubble agent. Viscoelastic properties of Definity and Sonazoid were assessed by measuring bulk modulus during incremental increases in ambient pressure to 200 mm Hg. Comparison of in vivo microbubble destruction and signal enhancement at a mechanical index (MI) of 0.1 to 0.4 was performed by sequential reduction in pulsing interval from 10 to 0.05 sec during limb CEU at 7 MHz in mice and 1.8 MHz in dogs. Destruction was also assessed by broadband signal generation during passive cavitation detection. Real-time CEU perfusion imaging with destruction-replenishment was then performed at 1.8 MHz in dogs using an MI of 0.1, 0.2, or 0.3. Sonazoid had a higher bulk modulus than Definity (66 ± 12 vs 29 ± 2 kPa, P = .02) and exhibited less inertial cavitation (destruction) at MIs ≥ 0.2. On in vivo CEU, maximal signal intensity increased incrementally with MI for both agents and was equivalent between agents except at an MI of 0.1 (60% and 85% lower for Sonazoid at 7 and 1.8 MHz, respectively, P power imaging coupled with a durable microbubble contrast agent. Copyright © 2015 American Society of Echocardiography. All rights reserved.

  5. Complex cystic renal masses: characterization with contrast-enhanced US.

    Science.gov (United States)

    Ascenti, Giorgio; Mazziotti, Silvio; Zimbaro, Giovanni; Settineri, Nicola; Magno, Carlo; Melloni, Darwin; Caruso, Rosario; Scribano, Emanuele

    2007-04-01

    To prospectively compare contrast material-enhanced ultrasonography (US) with computed tomography (CT) in the classification of complex cystic renal masses with the Bosniak system. Ethics committee approval and written informed consent were obtained. Forty patients (17 women, 23 men; age range, 31-77 years) with 44 complex cystic renal masses detected with conventional US were prospectively examined by using second-harmonic US with a second-generation contrast agent and multiphasic helical CT. Thirty-six patients had one lesion, and four patients had two lesions. Surgical resection in nine patients and imaging follow-up in 31 patients were used to determine the outcome. On contrast-enhanced US images, masses were classified as Bosniak category II (n = 18), IIF (ie, lesions were classified as category II and follow-up was needed) (n = 16), III (n = 7), or IV (n = 3) lesions. On CT images, masses were classified as Bosniak category II (n = 24), IIF (n = 10), III (n = 7), or IV (n = 3) lesions. Interobserver agreement was high (kappa = 0.86, P < .001) for classification with US. Complete concordance between the readers was found for classification with CT. Complete concordance between contrast-enhanced US and CT was observed in the differentiation of surgical and nonsurgical complex cysts. Complete concordance among the three readers in the assessment of vascularity with contrast-enhanced US was found. Interobserver agreement in the evaluation of enhancement on CT images was high (kappa = 0.88, P < .001). Concordance between contrast-enhanced US and CT in the evaluation of vascularization was high (kappa = 0.77, P < .001). The study data suggest that contrast-enhanced second-harmonic US is appropriate for renal cyst classification with the Bosniak system.

  6. Contrast enhancement technique in brain 3D-CTA studies. Optimizing the amount of contrast medium according to scan time based on TDC

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi

    2008-01-01

    In three-dimensional CT angiography (3D-CTA), good reproducibility can be obtained by maintaining the maximum CT numbers (HU) at a specified level. However, the correlation between the scan time and the injection time showed that the maximum CT numbers increased and varied due to the additional contrast enhancement effect from recirculation of the injected contrast medium for longer injection times when the dose of iodinated contrast medium per unit time (mgI/s) was maintained at a specified level based on the time-density curve (TDC) of the phantom. The amount of contrast medium employed at our hospital has been optimized based on an iodinated contrast medium dose per unit time providing a contrast enhancement effect of 300 HU in the middle cerebral artery. Using this standard, a TDC phantom was employed to obtain an iodinated contrast medium dose per unit time, permitting equivalent maximum CT values (used as standard values) to be obtained by changing the injection time. A contrast-enhancement technique that accounts for the variation in the scan time was evaluated. Strong correlations were observed between the scan time and the injection time (R 2 =0.969) and between the injection time and the dose of iodinated contrast medium per unit body weight (R 2 =0.994). We conclude that adjusting the dose of iodinated contrast medium per unit body weight per unit time according to the scan time permits optimization of the contrast-enhancement technique. (author)

  7. Use of contrast-enhanced ultrasonography in hepatosplenic sarcoidosis: Report of 2 cases

    International Nuclear Information System (INIS)

    Grzelak, Piotr; Augsburg, Lukasz; Majos, Agata; Stefanczyk, Ludomir; Gorski, Paweł; Piotrowski, Wojciech; Antczak, Adam

    2012-01-01

    Sarcoidosis is a multisystemic granulomatous disease of unknown etiology that predominantly affects lungs and intrathoracic lymph nodes; in rare cases (approx. 10%), infiltration of the spleen and liver may be observed. In order to identify hepatosplenic infiltration, MRI/CT of the abdomen and different ultrasound techniques (PD US, US D) are usually performed. Contrast enhanced ultrasound (CEUS) is a new technique in this diagnostic algorithm, but the fact that this is a safe, accurate, and widely available method opens a new perspective for the detection of abdominal lesions in sarcoidosis. We report 2 cases of hepatosplenic sarcoidosis – a 41-year-old woman with splenic lesions and a 46-year-old man with liver infiltration. On the basis of these 2 cases we intended to show the diagnostic potential of contrast enhanced ultrasound for the recognition of focal lesions of the spleen and liver in patients suffering from sarcoidosis

  8. Contrast enhanced ultrasound in the assessment of urogenital pathology

    Directory of Open Access Journals (Sweden)

    Libero Barozzi

    2014-12-01

    Full Text Available Contrast enhanced ultrasound (CEUS is an innovative technique that employs microbubble contrast agents to demonstrate parenchymal perfusion. Although initial clinical application was focused on the liver pathology, a wide variety of clinical conditions can be assessed now with CEUS. CEUS is a well-tolerated technique and is acquiring an increasing role in the assessment of renal pathology because contrast agents are not excreted by the kidney and do not affect the renal function. CEUS demonstrated an accuracy similar to contrast enhanced multi-detector computed tomography (CEMDCT in detecting focal lesions, with the advantage of the real-time assessment of microvascular perfusion by using time-intensity curves. The aim of this paper is to review the main indications of CEUS in the assessment of renal and urogenital pathology. Imaging examples are presented and described. Advantages and limitations of CEUS with reference to conventional US and CE-MDCT are discussed.

  9. Real-time movie image enhancement in NMR

    International Nuclear Information System (INIS)

    Doyle, M.; Mansfield, P.

    1986-01-01

    Clinical NMR motion picture (movie) images can now be produced routinely in real-time by ultra-high-speed echo-planar imaging (EPI). The single-shot image quality depends on both pixel resolution and signal-to-noise ratio (S/N), both factors being intertradeable. If image S/N is sacrificed rather than resolution, it is shown that S/N may be greatly enhanced subsequently without vitiating spatial resolution or foregoing real motional effects when the object motion is periodic. This is achieved by a Fourier filtering process. Experimental results are presented which demonstrate the technique for a normal functioning heart. (author)

  10. Hepatocellular carcinoma treated with transarterial chemoembolization: Evaluation with parametric contrast-enhanced ultrasonography

    Science.gov (United States)

    Moschouris, Hippocrates; Malagari, Katerina; Marinis, Athanasios; Kornezos, Ioannis; Stamatiou, Konstantinos; Nikas, Georgios; Papadaki, Marina Georgiou; Gkoutzios, Panagiotis

    2012-01-01

    AIM: To evaluate the response of hepatocellular carcinoma (HCC) to transarterial chemoembolization (TACE) using a simplified protocol of parametric contrast-enhanced ultrasound (pCEUS). METHODS: Eighteen patients with HCC (18 target tumors, diameter: 2.8-12 cm) were evaluated before, and 20 d after TACE. The distribution and morphology of TACE-induced necrosis in these tumors precluded accurate evaluation by visual assessment or by simple measurements. For pCEUS, a 4.8 mL bolus of SonoVue (Bracco, Milan, Italy) was intravenously administered and analysis of tumor perfusion during the initial phase of enhancement (0-30 s post injection) was performed with dedicated software (Qontrast, Bracco, Milan, Italy). Time-intensity curves were plotted and three parameters were calculated: peak intensity (PI, in percentage %), time to peak (TTP in seconds, s) and area under the curve during wash-in (AUC-WI, in arbitrary units, a.u). Magnetic resonance imaging was the standard imaging modality for post-treatment evaluation. Changes in tumor size were recorded and response was assessed according to response evaluation criteria in solid tumors criteria. RESULTS: A statistically significant decrease in PI and AUC-WI was observed in the treated tumors post TACE; PIpre: 21.5% ± 8.7% (mean ± SD), PIpost: 12.7% ± 6.7%, P < 0.001, AUC-WI pre: 17493 ± 9563 a.u, AUC-WI post: 9585 ± 5494 a.u, P < 0.001. A slight increase in TTP was noted post TACE, but this was not statistically significant; TTP pre: 13.1 ± 4.3 s, TTP post: 13.6 ± 4.2 s , P = 0.058). The changes in the aforementioned parameters were not accompanied by significant tumor shrinkage. CONCLUSION: pCEUS, even when limited to the study of the arterial phase of tumoral enhancement, can detect and quantify early perfusional changes in HCC post TACE. PMID:22937217

  11. Contrast-enhanced turbo spin-echo(TSE) T1-weighted imaging: improved contrast of enhancing lesions

    International Nuclear Information System (INIS)

    Choi, Sung Wook; Lee, Ghi Jai; Shim, Jae Chan; Lee, Young Ju; Jeong, Se Hyung; Kim, Ho kyun

    1997-01-01

    The purpose of this study was to evaluate the effect of contrast improvement of enhancing brain lesions by inherent magnetization transfer effect in turbo spin-echo(TSE)T1-weighted MR imaging. Twenty-six enhancing lesions of 19 patients were included in this study. Using a 1.0T superconductive MR unit, contrast-enhanced SE T1-weighted images(TR=3D600 msec, TE=3D12 msec, NEX=3D2, acquistition time=3D4min 27sec) and contrast-enhanced TSE T1-weighted images(TR=3D600 msec, TE=3D12, acquistition time=3D1min 44sec) were obtained. Signal intensities at enhancing lesions and adjacent white matter were measured in the same regions of both images. Signal-to-noise ratio(SNR) of enhancing lesions and adjacent white matter, and con-trast-to-noise ratio(CNR) and lesion-to-background contrast (LBC) of enhancing lesions were calculated and statistically analysed using the paired t-test. On contrast-enhanced TSE T1-weighted images, SNR of enhancing lesions and adjacent white matter decreased by 18%(p<0.01) and 32%(p<0.01), respectively, compared to contrast-enhanced SE T1-weighted images. CNR and LBC of enhancing lesions increased by 16%(p<0.05) and 66%(p<0.01), respectively. Due to the proposed inherent magnetization transfer effects in TSE imaging, con-trast-enhanced T1-weighted TSE images demonstrated a statistically significant improvement in CNR and LBC, compared to conventional contrast-enhanced T1-weighted SE images, and scan time was much shorter

  12. Blood Flow Changes in Subsynovial Connective Tissue on Contrast-Enhanced Ultrasonography in Patients With Carpal Tunnel Syndrome Before and After Surgical Decompression.

    Science.gov (United States)

    Motomiya, Makoto; Funakoshi, Tadanao; Ishizaka, Kinya; Nishida, Mutsumi; Matsui, Yuichiro; Iwasaki, Norimasa

    2017-11-24

    Although qualitative alteration of the subsynovial connective tissue in the carpal tunnel is considered to be one of the most important factors in the pathophysiologic mechanisms of carpal tunnel syndrome (CTS), little information is available about the microcirculation in the subsynovial connective tissue in patients with CTS. The aims of this study were to use contrast-enhanced ultrasonography (US) to evaluate blood flow in the subsynovial connective tissue proximal to the carpal tunnel in patients with CTS before and after carpal tunnel release. The study included 15 volunteers and 12 patients with CTS. The blood flow in the subsynovial connective tissue and the median nerve was evaluated preoperatively and at 1, 2, and 3 months postoperatively using contrast-enhanced US. The blood flow in the subsynovial connective tissue was higher in the patients with CTS than in the volunteers. In the patients with CTS, there was a significant correlation between the blood flow in the subsynovial connective tissue and the median nerve (P = .01). The blood flow in both the subsynovial connective tissue and the median nerve increased markedly after carpal tunnel release. Our results suggest that increased blood flow in the subsynovial connective tissue may play a role in the alteration of the microcirculation within the median nerve related to the pathophysiologic mechanisms of CTS. The increase in the blood flow in the subsynovial connective tissue during the early postoperative period may contribute to the changes in intraneural circulation, and these changes may lead to neural recovery. © 2017 by the American Institute of Ultrasound in Medicine.

  13. Contrast-enhanced ultrasonography and spiral computed tomography in the detection and characterization of portal vein thrombosis complicating hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Sandro; Ghittoni, Giorgia; Ravetta, Valentina; Torello Viera, Francesca; Rosa, Laura [Policlinico ' S. Matteo' Foundation, IRCCS, VI Department of Internal Medicine and Interventional Ultrasonography, Pavia (Italy); Serassi, Martina; Scabini, Mara; Vercelli, Alessandro; Calliada, Fabrizio [IRCCS Policlinico ' S. Matteo' , Department of Radiology, P.le Golgi n. 19, Pavia (Italy); Tinelli, Carmine [Biometrics Unit, IRCCS Policlinico ' S. Matteo' , Pavia (Italy); Dal Bello, Barbara [IRCCS Policlinico ' S. Matteo' , Department of Human Pathology, Pavia (Italy); Burns, Peter N. [University of Toronto, Department of Medical Biophysics, Toronto, ON (Canada); Imaging Research S660, Sunnybrook Health Science Centre, Toronto, ON (Canada)

    2008-08-15

    The aim was to compare the performances of contrast-enhanced (CE) ultrasonography (US) and spiral computed tomography (CT) in the detection and characterization of portal vein thrombosis complicating hepatocellular carcinoma (HCC). We studied 50 patients with HCC who had biopsy-proven portal vein thrombi that had been detected with US and color Doppler US. Thirteen of the thrombi involved the main portal trunk and 37 the segmental branches. CEUS and CT were performed within a week of thrombus biopsies. For each imaging technique, diagnoses of thrombosis (present/absent) and thrombus nature (malignancy/benignancy) were made by experienced readers under blinded conditions and compared with pathological findings to determine accuracy rates for thrombus detection and characterization. Forty-four of the 50 thrombi were pathologically diagnosed as malignant and the remaining six were benign. CEUS detected 50/50 (100%) thrombi and correctly characterized 49/50 (98%). CT detected 34/50 (68%) thrombi and correctly characterized 23 of these 34 (68%). CEUS outperformed CT in terms of both thrombus detection (P < 0.0001) and characterization (P = 0.0001). CEUS appears to be significantly superior to CT for detection and characterization of portal vein thrombosis complicating HCC, and it should be considered in the staging of these tumors. (orig.)

  14. Sporadic insulinomas on volume perfusion CT: dynamic enhancement patterns and timing of optimal tumour-parenchyma contrast

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Liang; Xue, Hua-dan; Liu, Wei; Wang, Xuan; Sun, Hao; Li, Ping; Jin, Zheng-yu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Wu, Wen-ming; Zhao, Yu-pei [Peking Union Medical College Hospital, Department of General Surgery, Beijing (China)

    2017-08-15

    To assess enhancement patterns of sporadic insulinomas on volume perfusion CT (VPCT), and to identify timing of optimal tumour-parenchyma contrast. Consecutive patients who underwent VPCT for clinically suspected insulinomas were retrospectively identified. Patients with insulinomas confirmed by surgery were included, and patients with familial syndromes were excluded. Two radiologists evaluated VPCT images in consensus. Tumour-parenchyma contrast at each time point was measured, and timing of optimal contrast was determined. Time duration of hyperenhancement (tumour-parenchyma contrast >20 Hounsfield units, HU) was recorded. Perfusion parameters were evaluated. Three dynamic enhancement patterns were observed in 63 tumours: persistent hyperenhancement (hyperenhancement time window ≥10 s) in 39 (61.9%), transient hyperenhancement (hyperenhancement <10 s) in 19 (30.2%) and non-hyperenhancement in 5 (7.9%). Timing of optimal contrast was 9 s after abdominal aorta threshold (AAT) of 200 HU, with tumour-parenchyma contrast of 77.6 ± 57.2 HU. At 9 s after AAT, 14 (22.2%) tumours were non-hyperenhancing, nine of which had missed transient hyperenhancement. Insulinomas with transient and persistent hyperenhancement patterns had significantly increased perfusion. Insulinomas have variable enhancement patterns. Tumour-parenchyma contrast is time-dependent. Optimal timing of enhancement is 9 s after AAT. VPCT enables tumour detection even if the hyperenhancement is transient. (orig.)

  15. Carotid Artery Stenosis: Comparison of 3D Time-of-Flight MR Angiography and Contrast-Enhanced MR Angiography at 3T

    Directory of Open Access Journals (Sweden)

    Ivan Platzek

    2014-01-01

    Full Text Available Purpose. The aim of this study was to assess the correlation of 3D time-of-flight MR angiography (TOF MRA and contrast-enhanced MR angiography (CEMRA for carotid artery stenosis evaluation at 3T. Material and Methods. Twenty-three patients (5 f, 18 m; mean age 61 y, age range 45–78 y with internal carotid artery stenosis detected with ultrasonography were examined on a 3.0T MR system. The MR examination included both 3D TOF MRA and CEMRA of the carotid arteries. MR images were evaluated independently by two board-certified radiologists. Stenosis evaluation was based on a five-point scale. Stenosis grades determined by TOF and CEMRA were compared using Spearman’s rank correlation coefficient and the Wilcoxon test. Cohen’s Kappa was used to evaluate interrater reliability. Results. CEMRA detected stenosis in 24 (52% of 46 carotids evaluated, while TOF detected stenosis in 27 (59% of 46 carotids. TOF MRA yielded significantly higher results for stenosis grade in comparison to CEMRA (P=0.014. Interrater agreement was very good for both TOF MRA (κ=0.93 and CEMRA (κ=0.93. Conclusion. At 3T, 3D TOF MRA should not be used as replacement for contrast-enhanced MRA of the carotid arteries, as it results in significantly higher stenosis grades.

  16. Renal contrast-enhanced MR angiography: timing errors and accurate depiction of renal artery origins.

    Science.gov (United States)

    Schmidt, Maria A; Morgan, Robert

    2008-10-01

    To investigate bolus timing artifacts that impair depiction of renal arteries at contrast material-enhanced magnetic resonance (MR) angiography and to determine the effect of contrast agent infusion rates on artifact generation. Renal contrast-enhanced MR angiography was simulated for a variety of infusion schemes, assuming both correct and incorrect timing between data acquisition and contrast agent injection. In addition, the ethics committee approved the retrospective evaluation of clinical breath-hold renal contrast-enhanced MR angiographic studies obtained with automated detection of contrast agent arrival. Twenty-two studies were evaluated for their ability to depict the origin of renal arteries in patent vessels and for any signs of timing errors. Simulations showed that a completely artifactual stenosis or an artifactual overestimation of an existing stenosis at the renal artery origin can be caused by timing errors of the order of 5 seconds in examinations performed with contrast agent infusion rates compatible with or higher than those of hand injections. Lower infusion rates make the studies more likely to accurately depict the origin of the renal arteries. In approximately one-third of all clinical examinations, different contrast agent uptake rates were detected on the left and right sides of the body, and thus allowed us to confirm that it is often impossible to optimize depiction of both renal arteries. In three renal arteries, a signal void was found at the origin in a patent vessel, and delayed contrast agent arrival was confirmed. Computer simulations and clinical examinations showed that timing errors impair the accurate depiction of renal artery origins. (c) RSNA, 2008.

  17. Semi-automatic motion compensation of contrast-enhanced ultrasound images from abdominal organs for perfusion analysis

    Czech Academy of Sciences Publication Activity Database

    Schafer, S.; Nylund, K.; Saevik, F.; Engjom, T.; Mézl, M.; Jiřík, Radovan; Dimcevski, G.; Gilja, O.H.; Tönnies, K.

    2015-01-01

    Roč. 63, AUG 1 (2015), s. 229-237 ISSN 0010-4825 R&D Projects: GA ČR GAP102/12/2380 Institutional support: RVO:68081731 Keywords : ultrasonography * motion analysis * motion compensation * registration * CEUS * contrast-enhanced ultrasound * perfusion * perfusion modeling Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 1.521, year: 2015

  18. Logistic regression analysis of conventional ultrasonography, strain elastosonography, and contrast-enhanced ultrasound characteristics for the differentiation of benign and malignant thyroid nodules.

    Science.gov (United States)

    Pang, Tiantian; Huang, Leidan; Deng, Yingyuan; Wang, Tianfu; Chen, Siping; Gong, Xuehao; Liu, Weixiang

    2017-01-01

    The aim of the study is to screen the significant sonographic features by logistic regression analysis and fit a model to diagnose thyroid nodules. A total of 525 pathological thyroid nodules were retrospectively analyzed. All the nodules underwent conventional ultrasonography (US), strain elastosonography (SE), and contrast -enhanced ultrasound (CEUS). Those nodules' 12 suspicious sonographic features were used to assess thyroid nodules. The significant features of diagnosing thyroid nodules were picked out by logistic regression analysis. All variables that were statistically related to diagnosis of thyroid nodules, at a level of p regression analysis model. The significant features in the logistic regression model of diagnosing thyroid nodules were calcification, suspected cervical lymph node metastasis, hypoenhancement pattern, margin, shape, vascularity, posterior acoustic, echogenicity, and elastography score. According to the results of logistic regression analysis, the formula that could predict whether or not thyroid nodules are malignant was established. The area under the receiver operating curve (ROC) was 0.930 and the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 83.77%, 89.56%, 87.05%, 86.04%, and 87.79% respectively.

  19. Added Value of Contrast-Enhanced Ultrasound on Biopsies of Focal Hepatic Lesions Invisible on Fusion Imaging Guidance.

    Science.gov (United States)

    Kang, Tae Wook; Lee, Min Woo; Song, Kyoung Doo; Kim, Mimi; Kim, Seung Soo; Kim, Seong Hyun; Ha, Sang Yun

    2017-01-01

    To assess whether contrast-enhanced ultrasonography (CEUS) with Sonazoid can improve the lesion conspicuity and feasibility of percutaneous biopsies for focal hepatic lesions invisible on fusion imaging of real-time ultrasonography (US) with computed tomography/magnetic resonance images, and evaluate its impact on clinical decision making. The Institutional Review Board approved this retrospective study. Between June 2013 and January 2015, 711 US-guided percutaneous biopsies were performed for focal hepatic lesions. Biopsies were performed using CEUS for guidance if lesions were invisible on fusion imaging. We retrospectively evaluated the number of target lesions initially invisible on fusion imaging that became visible after applying CEUS, using a 4-point scale. Technical success rates of biopsies were evaluated based on histopathological results. In addition, the occurrence of changes in clinical decision making was assessed. Among 711 patients, 16 patients (2.3%) were included in the study. The median size of target lesions was 1.1 cm (range, 0.5-1.9 cm) in pre-procedural imaging. After CEUS, 15 of 16 (93.8%) focal hepatic lesions were visualized. The conspicuity score was significantly increased after adding CEUS, as compared to that on fusion imaging (p making for 11 of 16 patients (68.8%). The addition of CEUS could improve the conspicuity of focal hepatic lesions invisible on fusion imaging. This dual guidance using CEUS and fusion imaging may affect patient management via changes in clinical decision-making.

  20. Selection of an early biomarker for vascular normalization using dynamic contrast-enhanced ultrasonography to predict outcomes of metastatic patients treated with bevacizumab.

    Science.gov (United States)

    Lassau, N; Coiffier, B; Kind, M; Vilgrain, V; Lacroix, J; Cuinet, M; Taieb, S; Aziza, R; Sarran, A; Labbe-Devilliers, C; Gallix, B; Lucidarme, O; Ptak, Y; Rocher, L; Caquot, L M; Chagnon, S; Marion, D; Luciani, A; Feutray, S; Uzan-Augui, J; Benatsou, B; Bonastre, J; Koscielny, S

    2016-10-01

    Dynamic contrast-enhanced ultrasonography (DCE-US) has been used for evaluation of tumor response to antiangiogenic treatments. The objective of this study was to assess the link between DCE-US data obtained during the first week of treatment and subsequent tumor progression. Patients treated with antiangiogenic therapies were included in a multicentric prospective study from 2007 to 2010. DCE-US examinations were available at baseline and at day 7. For each examination, a 3 min perfusion curve was recorded just after injection of a contrast agent. Each perfusion curve was modeled with seven parameters. We analyzed the correlation between criteria measured up to day 7 on freedom from progression (FFP). The impact was assessed globally, according to tumor localization and to type of treatment. The median follow-up was 20 months. The mean transit time (MTT) evaluated at day 7 was the only criterion significantly associated with FFP (P = 0.002). The cut-off point maximizing the difference between FFP curves was 12 s. Patients with at least a 12 s MTT had a better FFP. The results according to tumor type were significantly heterogeneous: the impact of MTT on FFP was more marked for breast cancer (P = 0.004) and for colon cancer (P = 0.025) than for other tumor types. Similarly, the differences in FFP according to MTT at day 7 were marked (P = 0.004) in patients receiving bevacizumab. The MTT evaluated with DCE-US at day 7 is significantly correlated to FFP of patients treated with bevacizumab. This criterion might be linked to vascular normalization. 2007-A00399-44. © The Author 2016. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  1. Neutral vs positive oral contrast in diagnosing acute appendicitis with contrast-enhanced CT: sensitivity, specificity, reader confidence and interpretation time

    Science.gov (United States)

    Naeger, D M; Chang, S D; Kolli, P; Shah, V; Huang, W; Thoeni, R F

    2011-01-01

    Objective The study compared the sensitivity, specificity, confidence and interpretation time of readers of differing experience in diagnosing acute appendicitis with contrast-enhanced CT using neutral vs positive oral contrast agents. Methods Contrast-enhanced CT for right lower quadrant or right flank pain was performed in 200 patients with neutral and 200 with positive oral contrast including 199 with proven acute appendicitis and 201 with other diagnoses. Test set disease prevalence was 50%. Two experienced gastrointestinal radiologists, one fellow and two first-year residents blindly assessed all studies for appendicitis (2000 readings) and assigned confidence scores (1=poor to 4=excellent). Receiver operating characteristic (ROC) curves were generated. Total interpretation time was recorded. Each reader's interpretation with the two agents was compared using standard statistical methods. Results Average reader sensitivity was found to be 96% (range 91–99%) with positive and 95% (89–98%) with neutral oral contrast; specificity was 96% (92–98%) and 94% (90–97%). For each reader, no statistically significant difference was found between the two agents (sensitivities p-values >0.6; specificities p-values>0.08), in the area under the ROC curve (range 0.95–0.99) or in average interpretation times. In cases without appendicitis, positive oral contrast demonstrated improved appendix identification (average 90% vs 78%) and higher confidence scores for three readers. Average interpretation times showed no statistically significant differences between the agents. Conclusion Neutral vs positive oral contrast does not affect the accuracy of contrast-enhanced CT for diagnosing acute appendicitis. Although positive oral contrast might help to identify normal appendices, we continue to use neutral oral contrast given its other potential benefits. PMID:20959365

  2. Evaluation of hepatobiliary imaging by radionuclide scintigraphy, ultrasonography, and contrast cholangiography

    International Nuclear Information System (INIS)

    Cheng, T.H.; Davis, M.A.; Seltzer, S.E.; Jones, B.; Abbruzzese, A.A.; Finberg, H.J.; Drum, D.E.

    1979-01-01

    Cholescintigraphy, ultrasonography, and contrast cholangiography were compared in 60 patients. Among those having abdominal pain but no biliary disease or jaundice, cholescintigraphy was normal in 14/14, ultrasound in 10/13, and cholangiography in 13/14. Jaundice due to hepatocellular disease was correctly distinguished from complete biliary obstruction by cholescintigraphy in 17/17 patients and by ultrasound in 14/17. In cholelithiasis, ultrasound was abnormal in 10/12 and cholangiography in 7/9. Cholescintigraphy appeared most sensitive to active cholecystitis; only cholangiography and ultrasound visualized gallstones

  3. An enhanced Ada run-time system for real-time embedded processors

    Science.gov (United States)

    Sims, J. T.

    1991-01-01

    An enhanced Ada run-time system has been developed to support real-time embedded processor applications. The primary focus of this development effort has been on the tasking system and the memory management facilities of the run-time system. The tasking system has been extended to support efficient and precise periodic task execution as required for control applications. Event-driven task execution providing a means of task-asynchronous control and communication among Ada tasks is supported in this system. Inter-task control is even provided among tasks distributed on separate physical processors. The memory management system has been enhanced to provide object allocation and protected access support for memory shared between disjoint processors, each of which is executing a distinct Ada program.

  4. Microbubble responses to a similar mechanical index with different real-time perfusion imaging techniques.

    Science.gov (United States)

    Porter, Thomas R; Oberdorfer, Joseph; Rafter, Patrick; Lof, John; Xie, Feng

    2003-08-01

    The purpose of this study was to determine differences in contrast enhancement and microbubble destruction rates with current commercially available low-mechanical index (MI) real-time perfusion imaging modalities. A tissue-mimicking phantom was developed that had vessels at 3 cm (near field) and 9 cm (far field) from a real-time transducer. Perfluorocarbon-exposed sonicated dextrose albumin microbubbles (PESDA) were injected proximal to a mixing chamber, and then passed through these vessels while the region was insonified with either pulses of alternating polarity with pulse inversion Doppler (PID) or pulses of alternating amplitude by power modulation (PM) at MIs of 0.1, 0.2 and 0.3. Effluent microbubble concentration, contrast intensity and the slope of digital contrast intensity vs. time were measured. Our results demonstrated that microbubble destruction already occurs with PID at an MI of 0.1. Contrast intensity seen with PID was less than with PM. Therefore, differences in contrast enhancement and microbubble destruction rates occur at a similar MI setting when using different real-time pulse sequence schemes.

  5. Ultrasonography of the canine pancreas

    Directory of Open Access Journals (Sweden)

    Michelle L Avante

    2018-01-01

    Full Text Available This study describes the ultrasonographic techniques currently used in the evaluation of the canine pancreas. Ultrasonography was the first method to enable direct visualization of the pancreas in humans and it has been subsequently applied to animals. Currently, it is the method of choice for pancreatic evaluation and is essential as a diagnostic tool in the detection of abnormalities, especially tumors. Innovative equipment technology has led to the emergence of techniques complementary to B-mode ultrasound; such as Doppler, elastography, and contrast-enhanced ultrasonography, which have enabled more accurate diagnosis. Doppler provides information on vascular architecture and the hemodynamic aspect of blood vessels in multiple organs. ARFI elastography provides detailed images of the alterations detected by conventional examination (qualitative method and assists in differentiating between benign and malignant processes (quantitative method. Microbubble contrast agents determine parameters related to homogeneous and heterogeneous filling of organs with microbubbles, mainly nodular areas, thus defining high and low intensity patterns.

  6. Ultrasonography in abdominal emergencies

    International Nuclear Information System (INIS)

    Risi, D.; Alessi, G.; Meli, C.; Marzano, M.; Fiori, E.; Caterino, S.

    1989-01-01

    From February 1986 to March 1988 113 abdominal US exams were performed in emergency situation to evaluate the accuracy of this methodology: 13 were blunt traumas, 18 post-operative complications. A real-time scanner with a linear probe of 5 MHz was employed. The results were confirmed by surgical and/or clinical and instrumental evaluation. In 81% of the examinations, ultrasonography allowed a diagnosis to be made. Gallbladder and biliary pathologies were the most common findings. The results (sensibility 96%, specificity 88%, accuracy 95%) confirm the affidability of ultrasonography in abdominal emergencies, as shown in literature

  7. A new method to study changes in microvascular blood volume in muscle and adipose tissue: Real time imaging in humans and rat

    DEFF Research Database (Denmark)

    Sjøberg, Kim Anker; Rattigan, Stephen; Hiscock, Natalie J

    2011-01-01

    We employed and evaluated a new application of contrast enhanced ultrasound for real time imaging of changes in microvascular blood volume (MVB) in tissues in females, males and rat. Continuous real time imaging was performed using contrast enhanced ultrasound to quantify infused gas filled micro...

  8. Contrast-enhanced harmonic endoscopic ultrasound

    DEFF Research Database (Denmark)

    Săftoiu, A; Dietrich, C F; Vilmann, P

    2012-01-01

    Second-generation intravenous blood-pool ultrasound contrast agents are increasingly used in endoscopic ultrasound (EUS) for characterization of microvascularization, differential diagnosis of benign and malignant focal lesions, and improving staging and guidance of therapeutic procedures. Although...... initially used as Doppler signal enhancers, second-generation microbubble contrast agents are now used with specific contrast harmonic imaging techniques, which benefit from the highly nonlinear behavior of the microbubbles. Contrast-specific modes based on multi-pulse technology are used to perform...... contrast-enhanced harmonic EUS based on a very low mechanical index (0.08 - 0.12). Quantification techniques based on dynamic contrast-enhanced ultrasound have been recommended for perfusion imaging and monitoring of anti-angiogenic treatment, mainly based on time-intensity curve analysis. Most...

  9. Contrast enhanced ultrasound of sentinel lymph nodes

    Directory of Open Access Journals (Sweden)

    XinWu Cui

    2013-03-01

    Full Text Available Sentinel lymph nodes are the first lymph nodes in the region that receive lymphatic drainage from a primary tumor. The detection or exclusion of sentinel lymph node micrometastases is critical in the staging of cancer, especially breast cancer and melanoma because it directly affects patient’s prognosis and surgical management. Currently, intraoperative sentinel lymph node biopsies using blue dye and radioisotopes are the method of choice for the detection of sentinel lymph node with high identification rate. In contrast, conventional ultrasound is not capable of detecting sentinel lymph nodes in most cases. Contrast enhanced ultrasound with contrast specific imaging modes has been used for the evaluation and diagnostic work-up of peripherally located suspected lymphadenopathy. The method allows for real-time analysis of all vascular phases and the visualization of intranodal focal “avascular” areas that represent necrosis or deposits of neoplastic cells. In recent years, a number of animal and human studies showed that contrast enhanced ultrasound can be also used for the detection of sentinel lymph node, and may become a potential application in clinical routine. Several contrast agents have been used in those studies, including albumin solution, hydroxyethylated starch, SonoVue®, Sonazoid® and Definity®. This review summarizes the current knowledge about the use of ultrasound techniques in detection and evaluation of sentinel lymph node.

  10. Added value of contrast-enhanced ultrasound on biopsies of focal hepatic lesions invisible on fusion imaging guidance

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Tae Wook; Lee, Min Woo; Song, Kyoung Doo; Kim, Mimi; Kim, Seung Soo; Kim, Seong Hyun; Ha, Sang Yun [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-01-15

    To assess whether contrast-enhanced ultrasonography (CEUS) with Sonazoid can improve the lesion conspicuity and feasibility of percutaneous biopsies for focal hepatic lesions invisible on fusion imaging of real-time ultrasonography (US) with computed tomography/magnetic resonance images, and evaluate its impact on clinical decision making. The Institutional Review Board approved this retrospective study. Between June 2013 and January 2015, 711 US-guided percutaneous biopsies were performed for focal hepatic lesions. Biopsies were performed using CEUS for guidance if lesions were invisible on fusion imaging. We retrospectively evaluated the number of target lesions initially invisible on fusion imaging that became visible after applying CEUS, using a 4-point scale. Technical success rates of biopsies were evaluated based on histopathological results. In addition, the occurrence of changes in clinical decision making was assessed. Among 711 patients, 16 patients (2.3%) were included in the study. The median size of target lesions was 1.1 cm (range, 0.5–1.9 cm) in pre-procedural imaging. After CEUS, 15 of 16 (93.8%) focal hepatic lesions were visualized. The conspicuity score was significantly increased after adding CEUS, as compared to that on fusion imaging (p < 0.001). The technical success rate of biopsy was 87.6% (14/16). After biopsy, there were changes in clinical decision making for 11 of 16 patients (68.8%). The addition of CEUS could improve the conspicuity of focal hepatic lesions invisible on fusion imaging. This dual guidance using CEUS and fusion imaging may affect patient management via changes in clinical decision-making.

  11. Added value of contrast-enhanced ultrasound on biopsies of focal hepatic lesions invisible on fusion imaging guidance

    International Nuclear Information System (INIS)

    Kang, Tae Wook; Lee, Min Woo; Song, Kyoung Doo; Kim, Mimi; Kim, Seung Soo; Kim, Seong Hyun; Ha, Sang Yun

    2017-01-01

    To assess whether contrast-enhanced ultrasonography (CEUS) with Sonazoid can improve the lesion conspicuity and feasibility of percutaneous biopsies for focal hepatic lesions invisible on fusion imaging of real-time ultrasonography (US) with computed tomography/magnetic resonance images, and evaluate its impact on clinical decision making. The Institutional Review Board approved this retrospective study. Between June 2013 and January 2015, 711 US-guided percutaneous biopsies were performed for focal hepatic lesions. Biopsies were performed using CEUS for guidance if lesions were invisible on fusion imaging. We retrospectively evaluated the number of target lesions initially invisible on fusion imaging that became visible after applying CEUS, using a 4-point scale. Technical success rates of biopsies were evaluated based on histopathological results. In addition, the occurrence of changes in clinical decision making was assessed. Among 711 patients, 16 patients (2.3%) were included in the study. The median size of target lesions was 1.1 cm (range, 0.5–1.9 cm) in pre-procedural imaging. After CEUS, 15 of 16 (93.8%) focal hepatic lesions were visualized. The conspicuity score was significantly increased after adding CEUS, as compared to that on fusion imaging (p < 0.001). The technical success rate of biopsy was 87.6% (14/16). After biopsy, there were changes in clinical decision making for 11 of 16 patients (68.8%). The addition of CEUS could improve the conspicuity of focal hepatic lesions invisible on fusion imaging. This dual guidance using CEUS and fusion imaging may affect patient management via changes in clinical decision-making

  12. Ring-enhancement pattern on contrast-enhanced CT predicts adenosquamous carcinoma of the pancreas: a matched case-control study.

    Science.gov (United States)

    Imaoka, Hiroshi; Shimizu, Yasuhiro; Mizuno, Nobumasa; Hara, Kazuo; Hijioka, Susumu; Tajika, Masahiro; Tanaka, Tsutomu; Ishihara, Makoto; Ogura, Takeshi; Obayashi, Tomohiko; Shinagawa, Akihide; Sakaguchi, Masafumi; Yamaura, Hidekazu; Kato, Mina; Niwa, Yasumasa; Yamao, Kenji

    2014-01-01

    Adenosquamous carcinoma of the pancreas (ASC) is a rare malignant neoplasm of the pancreas, exhibiting both glandular and squamous differentiation. However, little is known about its imaging features. This study examined the imaging features of pancreatic ASC. We evaluated images of contrast-enhanced computed tomography (CT) and endoscopic ultrasonography (EUS). As controls, solid pancreatic neoplasms matched in a 2:1 ratio to ASC cases for age, sex and tumor location were also evaluated. Twenty-three ASC cases were examined, and 46 solid pancreatic neoplasms (43 pancreatic ductal adenocarcinomas, two pancreatic neuroendocrine tumors and one acinar cell carcinoma) were matched as controls. Univariate analysis demonstrated significant differences in the outline and vascularity of tumors on contrast-enhanced CT in the ASC and control groups (P outline, cystic changes, and the ring-enhancement pattern on contrast-enhanced CT were seen to have significant predictive powers by stepwise forward logistic regression analysis (P = 0.044, P = 0.010, and P = 0.001, respectively). Of the three, the ring-enhancement pattern was the most useful, and its predictive diagnostic sensitivity, specificity, positive predictive value and negative predictive value for diagnosis of ASC were 65.2%, 89.6%, 75.0% and 84.3%, respectively. These results demonstrate that presence of the ring-enhancement pattern on contrast-enhanced CT is the most useful predictive factor for ASC. Copyright © 2014 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  13. Ab initio quantum-enhanced optical phase estimation using real-time feedback control

    DEFF Research Database (Denmark)

    Berni, Adriano; Gehring, Tobias; Nielsen, Bo Melholt

    2015-01-01

    of a quantum-enhanced and fully deterministic ab initio phase estimation protocol based on real-time feedback control. Using robust squeezed states of light combined with a real-time Bayesian adaptive estimation algorithm, we demonstrate deterministic phase estimation with a precision beyond the quantum shot...... noise limit. The demonstrated protocol opens up new opportunities for quantum microscopy, quantum metrology and quantum information processing....

  14. Contrast-enhanced color Doppler US in breast cancer: Tumoral vascularity correlated with angiogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun A; Yoon, Kwon Ha; Yun, Ki Jung; Lee, Kwang Man; Park, Ki Han; Juhng, Seon Kwan; Won, Jong Jin [Wonkwang University School of Medicine, Seoul (Korea, Republic of)

    2000-12-15

    To evaluate the effects of contrast-enhanced color Doppler ultrasonography (CDUS) on the depiction of vascularity and flow pattern in breast cancer and to determine the relationship between tumoral vascularity and angiogenesis. Twenty-one patients with breast cancer were prospectively evaluated with CDUS before and after injection of the contrast agent (SH U 508A, 2.5g, 300 mg/ml ). The tumoral vascularity was expressed as percentage of color Doppler area, which was measured quantitatively by a computerized program (Ultrasonic Imaging Tool; Soongsil University, Seoul, Korea). The flow pattern (four-patterns; spotty, linear, branching, marginal) of the vascularity was analyzed. After surgery, tumor angiogenesis was assessed by microvessel density. The relationship between the vascularity on CDUS and microvessel density was statistically analyzed. At unenhanced CDUS, tumoral flow signals were detected in 12 lesions (48%); at contrast-enhanced CDUS, 18 lesions (86%). All These 18 lesions showed increased signals, compared with those at unenhanced CDUS. The percentage color Doppler area was 1.86 {+-} 0.48% at unenhanced CDUS and 5.23 {+-} 1.18% at contrast-enhanced CDUS. The flow patterns before contrast injection were spotty pattern in 11 tumors and linear pattern in one; after contrast injection, spotty in 8, linear in 4, branching in 5, and marginal in one. The tumoral vascularity at contrast-enhanced CDUS showed no significant correlation with microvessel density. Contrast-enhanced CDUS seems to be a valuable tool in the depiction of vascularity and characterization of flow pattern in breast cancer. However, tumoral vascularity on CDUS may not reflect tumoral angiogenesis.

  15. Real-time acquisition and display of flow contrast using speckle variance optical coherence tomography in a graphics processing unit.

    Science.gov (United States)

    Xu, Jing; Wong, Kevin; Jian, Yifan; Sarunic, Marinko V

    2014-02-01

    In this report, we describe a graphics processing unit (GPU)-accelerated processing platform for real-time acquisition and display of flow contrast images with Fourier domain optical coherence tomography (FDOCT) in mouse and human eyes in vivo. Motion contrast from blood flow is processed using the speckle variance OCT (svOCT) technique, which relies on the acquisition of multiple B-scan frames at the same location and tracking the change of the speckle pattern. Real-time mouse and human retinal imaging using two different custom-built OCT systems with processing and display performed on GPU are presented with an in-depth analysis of performance metrics. The display output included structural OCT data, en face projections of the intensity data, and the svOCT en face projections of retinal microvasculature; these results compare projections with and without speckle variance in the different retinal layers to reveal significant contrast improvements. As a demonstration, videos of real-time svOCT for in vivo human and mouse retinal imaging are included in our results. The capability of performing real-time svOCT imaging of the retinal vasculature may be a useful tool in a clinical environment for monitoring disease-related pathological changes in the microcirculation such as diabetic retinopathy.

  16. Early quantification of the therapeutic efficacy of the vascular disrupting agent, CKD-516, using dynamic contrast-enhanced ultrasonography in rabbit VX2 liver tumors

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Ijin; Kim, Jung Hoon; Lee, Jeong Min; Choi, Jin Woo; Han, Joon Koo; Choi, Byung Ihn [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2014-03-15

    To evaluate the usefulness of dynamic contrast-enhanced ultrasonography (DCE-US) in the early quantification of hemodynamic change following administration of the vascular disrupting agent (VDA) CKD-516 using a rabbit VX2 liver tumor model. This study was approved by our institutional animal care and use committee. Eight VX2 liver-tumor-bearing rabbits were treated with intravenous CKD-516, and all underwent DCE-US using SonoVue before and again 2, 4, 6, and 24 hours following their treatment. The tumor perfusion parameters were obtained from the time-intensity curve of the DCE-US data. Repeated measures analysis of variance was performed to assess any significant change in tumor perfusion over time. Relative changes in the DCE-US parameters between the baseline and follow-up assessments were correlated with the relative changes in tumor size over the course of seven days using Pearson correlation. CKD-516 treatment resulted in significant changes in the DCE-US parameters, including the peak intensity, total area under the time-intensity curve (AUCtotal), and AUC during wash-out (AUCout) over time (P<0.05). Pairwise comparison tests revealed that the AUCtotal and AUC during wash-in (AUCin) seen on the two-hour follow-up were significantly lower than the baseline values (P<0.05). However, none of early changes in the DCE-US parameters until 24-hour follow-up showed a significant correlation with the relative changes in tumor size during seven days after CKD-516 treatment. Our results suggest that a novel VDA (CKD-516) can cause disruption of tumor perfusion as early as two hours after treatment and that the therapeutic effect of CKD-516 treatment can be effectively quantified using DCE-US.

  17. Microbubbles as contrast agent for in-line x-ray phase-contrast imaging

    International Nuclear Information System (INIS)

    Xi Yan; Zhao Jun; Tang Rongbiao; Wang Yujie

    2011-01-01

    In the present study, we investigated the potential of gas-filled microbubbles as contrast agents for in-line x-ray phase-contrast imaging (PCI) in biomedical applications. When imaging parameters are optimized, the microbubbles function as microlenses that focus the incoming x-rays to form bright spots, which can significantly enhance the image contrast. Since microbubbles have been shown to be safe contrast agents in clinical ultrasonography, this contrast-enhancement procedure for PCI may have promising utility in biomedical applications, especially when the dose of radiation is a serious concern. In this study, we performed both numerical simulations and ex vivo experiments to investigate the formation of the contrast and the effectiveness of microbubbles as contrast agents in PCI.

  18. The Natural History of Kidney Graft Cortical Microcirculation Determined by Real-Time Contrast-Enhanced Sonography (RT-CES).

    Science.gov (United States)

    Jiménez, Carlos; López, María Ovidia; Ros, Amaia; Aguilar, Ana; Menendez, David; Rivas, Begoña; Santana, María José; Vaca, Marco Antonio; Escuin, Fernando; Madero, Rosario; Selgas, Rafael

    2016-01-01

    Kidney transplantation is the therapy of choice for end-stage kidney disease. Graft's life span is shorter than expected due in part to the delayed diagnosis of various complications, specifically those related to silent progression. It is recognized that serum creatinine levels and proteinuria are poor markers of mild kidney lesions, which results in delayed clinical information. There are many investigation looking for early markers of graft damage. Decreasing kidney graft cortical microcirculation has been related to poor prognosis in kidney transplantation. Cortical capillary blood flow (CCBF) can be measured by real-time contrast-enhanced sonography (RT-CES). Our aim was to describe the natural history of CCBF over time under diverse conditions of kidney transplantation, to explore the influence of donor conditions and recipient events, and to determine the capacity of CCBF for predicting renal function in medium term. RT-CES was performed in 79 consecutive kidney transplant recipients during the first year under regular clinical practice. Cortical capillary blood flow was measured. Clinical variables were analyzed. The influence of CCBF has been determined by univariate and multivariate analysis using mixed regression models based on sequential measurements for each patient over time. We used a first-order autoregression model as the structure of the covariation between measures. The post-hoc comparisons were considered using the Bonferroni correction. The CCBF values varied significantly over the study periods and were significantly lower at 48 h and day 7. Brain-death donor age and CCBF levels showed an inverse relationship (r: -0.62, p<0.001). Living donors showed higher mean CCBF levels than brain-death donors at each point in the study. These significant differences persisted at month 12 (54.5 ± 28.2 vs 33.7 ± 30 dB/sec, living vs brain-death donor, respectively, p = 0.004) despite similar serum creatinine levels (1.5 ± 0.3 and 1.5 ± 0.5 mg/dL). A

  19. Vesicoureteral reflux in children: comparison of contrast - enhanced voiding ultrasonography with radiographic voiding cystourethrography - preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Chong Hyun; Kim, Hyun Joo; Goo, Hyun Woo; Kim, Hungy; Lee, Jung Joo; Kim, Ellen Ai-Rhan; Kim, Ki Soo; Park, Young Seo; Pi, Soo Young [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    2001-01-01

    To compared the usefullness of contrst-enhanced voiding ultrasonogrphy (US) with that of radiogrphic voiding cystourethrography (VCUG) for the diagnosis of vesicoureteral reflux (VUR) in children. Ninety-five kidney-ureter units of 47 patients referred for investigation of VUR underwent contrast -enhanced voiding US followed by radiographic VCUG. After baseline US examination of the urinaru tract, residual urine in the bladder was drained through an inserted Foley catheter and the bladder was gravityfilled at a height of 1 m with normal saline. A galactose-based, microbubble-containning echo-enhancing agent (Lvovist; Dchering, Berlin, Germany) was then administered. The amount of this was approximately 10% of bldder capacity, and VUR was diagnosed when microbubbles appeared in the ureter or pelvocalyceal system. Using radiographic VCUG as a reference point, the accuracy with which contrst-enhanced voiding US detected VUR was calcilated. In 87 of 95 kidney-ureter units (91.6%), the two methods showed similiar results regarding the diagnosis or exclusion of VUR, which was detected by both in 12 units, but by neither in 75. VUR was shown to occcur in a total of 20 units, but in eight of these by one method only. In two units, VUR detected by contrast-enhanced voiding US was was not demostarted by radiographic VCUG; in six units, the resverse was true. In the detection of VUR, contrast-enhanced voiding us showed a sensitivity of 66.7%, a sprcificity of 97.4%, a positive predictive value of 85.7%, and a negative predictive value of 92.6%. Contrst-enhanced voiding US is highly specific and has high positive and nagative predictive values; its sensitivity, however, is not sufficiently high. The modality appears to be a useful diagnostic tool for the detection of VUR without exposure to ionizing radiation, though to be certain of its value, more experience of its use its first required.

  20. Vesicoureteral reflux in children: comparison of contrast - enhanced voiding ultrasonography with radiographic voiding cystourethrography - preliminary report

    International Nuclear Information System (INIS)

    Yoon, Chong Hyun; Kim, Hyun Joo; Goo, Hyun Woo; Kim, Hungy; Lee, Jung Joo; Kim, Ellen Ai-Rhan; Kim, Ki Soo; Park, Young Seo; Pi, Soo Young

    2001-01-01

    To compared the usefullness of contrst-enhanced voiding ultrasonogrphy (US) with that of radiogrphic voiding cystourethrography (VCUG) for the diagnosis of vesicoureteral reflux (VUR) in children. Ninety-five kidney-ureter units of 47 patients referred for investigation of VUR underwent contrast -enhanced voiding US followed by radiographic VCUG. After baseline US examination of the urinaru tract, residual urine in the bladder was drained through an inserted Foley catheter and the bladder was gravityfilled at a height of 1 m with normal saline. A galactose-based, microbubble-containning echo-enhancing agent (Lvovist; Dchering, Berlin, Germany) was then administered. The amount of this was approximately 10% of bldder capacity, and VUR was diagnosed when microbubbles appeared in the ureter or pelvocalyceal system. Using radiographic VCUG as a reference point, the accuracy with which contrst-enhanced voiding US detected VUR was calcilated. In 87 of 95 kidney-ureter units (91.6%), the two methods showed similiar results regarding the diagnosis or exclusion of VUR, which was detected by both in 12 units, but by neither in 75. VUR was shown to occcur in a total of 20 units, but in eight of these by one method only. In two units, VUR detected by contrast-enhanced voiding US was was not demostarted by radiographic VCUG; in six units, the resverse was true. In the detection of VUR, contrast-enhanced voiding us showed a sensitivity of 66.7%, a sprcificity of 97.4%, a positive predictive value of 85.7%, and a negative predictive value of 92.6%. Contrst-enhanced voiding US is highly specific and has high positive and nagative predictive values; its sensitivity, however, is not sufficiently high. The modality appears to be a useful diagnostic tool for the detection of VUR without exposure to ionizing radiation, though to be certain of its value, more experience of its use its first required

  1. Adaptive sound speed correction for abdominal ultrasonography: preliminary results

    Science.gov (United States)

    Jin, Sungmin; Kang, Jeeun; Song, Tai-Kyung; Yoo, Yangmo

    2013-03-01

    Ultrasonography has been conducting a critical role in assessing abdominal disorders due to its noninvasive, real-time, low cost, and deep penetrating capabilities. However, for imaging obese patients with a thick fat layer, it is challenging to achieve appropriate image quality with a conventional beamforming (CON) method due to phase aberration caused by the difference between sound speeds (e.g., 1580 and 1450m/s for liver and fat, respectively). For this, various sound speed correction (SSC) methods that estimate the accumulated sound speed for a region-of interest (ROI) have been previously proposed. However, with the SSC methods, the improvement in image quality was limited only for a specific depth of ROI. In this paper, we present the adaptive sound speed correction (ASSC) method, which can enhance the image quality for whole depths by using estimated sound speeds from two different depths in the lower layer. Since these accumulated sound speeds contain the respective contributions of layers, an optimal sound speed for each depth can be estimated by solving contribution equations. To evaluate the proposed method, the phantom study was conducted with pre-beamformed radio-frequency (RF) data acquired with a SonixTouch research package (Ultrasonix Corp., Canada) with linear and convex probes from the gel pad-stacked tissue mimicking phantom (Parker Lab. Inc., USA and Model539, ATS, USA) whose sound speeds are 1610 and 1450m/s, respectively. From the study, compared to the CON and SSC methods, the ASSC method showed the improved spatial resolution and information entropy contrast (IEC) for convex and linear array transducers, respectively. These results indicate that the ASSC method can be applied for enhancing image quality when imaging obese patients in abdominal ultrasonography.

  2. Real-time detection of gastric insufflation related to facemask pressure-controlled ventilation using ultrasonography of the antrum and epigastric auscultation in nonparalyzed patients: a prospective, randomized, double-blind study.

    Science.gov (United States)

    Bouvet, Lionel; Albert, Marie-Laure; Augris, Caroline; Boselli, Emmanuel; Ecochard, René; Rabilloud, Muriel; Chassard, Dominique; Allaouchiche, Bernard

    2014-02-01

    The authors sought to determine the level of inspiratory pressure minimizing the risk of gastric insufflation while providing adequate pulmonary ventilation. The primary endpoint was the increase in incidence of gastric insufflation detected by ultrasonography of the antrum while inspiratory pressure for facemask pressure-controlled ventilation increased from 10 to 25 cm H2O. In this prospective, randomized, double-blind study, patients were allocated to one of the four groups (P10, P15, P20, and P25) defined by the inspiratory pressure applied during controlled-pressure ventilation: 10, 15, 20, and 25 cm H2O. Anesthesia was induced using propofol and remifentanil; no neuromuscular-blocking agent was administered. Once loss of eyelash reflex occurred, facemask ventilation was started for a 2-min period while gastric insufflation was detected by auscultation and by real-time ultrasonography of the antrum. The cross-sectional antral area was measured using ultrasonography before and after facemask ventilation. Respiratory parameters were recorded. Sixty-seven patients were analyzed. The authors registered statistically significant increases in incidences of gastric insufflation with inspiratory pressure, from 0% (group P10) to 41% (group P25) according to auscultation, and from 19 to 59% according to ultrasonography. In groups P20 and P25, detection of gastric insufflation by ultrasonography was associated with a statistically significant increase in the antral area. Lung ventilation was insufficient for group P10. Inspiratory pressure of 15 cm H2O allowed for reduced occurrence of gastric insufflation with proper lung ventilation during induction of anesthesia with remifentanil and propofol in nonparalyzed and nonobese patients. (Anesthesiology 2014; 120:326-34).

  3. Positioning Ultrasonography Into Clinical Practice for the Management of Crohn’s Disease

    Science.gov (United States)

    Zorzi, Francesca; Lolli, Elisabetta; Pallone, Francesco

    2015-01-01

    Over the past few years, the technical evolution of ultrasound equipment, the use of oral and intravenous contrast agents, and an increase in the expertise of operators have enhanced the role that ultrasonography plays in the assessment of the gastrointestinal tract. For patients with chronic inflammatory conditions, particularly Crohn’s disease, it has been suggested that ultrasonography can be used not only for diagnostic purposes but also in disease management. These developments are reviewed in this article. PMID:27118932

  4. Real-time automatic fiducial marker tracking in low contrast cine-MV images

    International Nuclear Information System (INIS)

    Lin, Wei-Yang; Lin, Shu-Fang; Yang, Sheng-Chang; Liou, Shu-Cheng; Nath, Ravinder; Liu Wu

    2013-01-01

    Purpose: To develop a real-time automatic method for tracking implanted radiographic markers in low-contrast cine-MV patient images used in image-guided radiation therapy (IGRT). Methods: Intrafraction motion tracking using radiotherapy beam-line MV images have gained some attention recently in IGRT because no additional imaging dose is introduced. However, MV images have much lower contrast than kV images, therefore a robust and automatic algorithm for marker detection in MV images is a prerequisite. Previous marker detection methods are all based on template matching or its derivatives. Template matching needs to match object shape that changes significantly for different implantation and projection angle. While these methods require a large number of templates to cover various situations, they are often forced to use a smaller number of templates to reduce the computation load because their methods all require exhaustive search in the region of interest. The authors solve this problem by synergetic use of modern but well-tested computer vision and artificial intelligence techniques; specifically the authors detect implanted markers utilizing discriminant analysis for initialization and use mean-shift feature space analysis for sequential tracking. This novel approach avoids exhaustive search by exploiting the temporal correlation between consecutive frames and makes it possible to perform more sophisticated detection at the beginning to improve the accuracy, followed by ultrafast sequential tracking after the initialization. The method was evaluated and validated using 1149 cine-MV images from two prostate IGRT patients and compared with manual marker detection results from six researchers. The average of the manual detection results is considered as the ground truth for comparisons. Results: The average root-mean-square errors of our real-time automatic tracking method from the ground truth are 1.9 and 2.1 pixels for the two patients (0.26 mm/pixel). The

  5. Real-time automatic fiducial marker tracking in low contrast cine-MV images

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Wei-Yang; Lin, Shu-Fang; Yang, Sheng-Chang; Liou, Shu-Cheng; Nath, Ravinder; Liu Wu [Department of Computer Science and Information Engineering, National Chung Cheng University, Taiwan, 62102 (China); Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut 06510-3220 (United States)

    2013-01-15

    Purpose: To develop a real-time automatic method for tracking implanted radiographic markers in low-contrast cine-MV patient images used in image-guided radiation therapy (IGRT). Methods: Intrafraction motion tracking using radiotherapy beam-line MV images have gained some attention recently in IGRT because no additional imaging dose is introduced. However, MV images have much lower contrast than kV images, therefore a robust and automatic algorithm for marker detection in MV images is a prerequisite. Previous marker detection methods are all based on template matching or its derivatives. Template matching needs to match object shape that changes significantly for different implantation and projection angle. While these methods require a large number of templates to cover various situations, they are often forced to use a smaller number of templates to reduce the computation load because their methods all require exhaustive search in the region of interest. The authors solve this problem by synergetic use of modern but well-tested computer vision and artificial intelligence techniques; specifically the authors detect implanted markers utilizing discriminant analysis for initialization and use mean-shift feature space analysis for sequential tracking. This novel approach avoids exhaustive search by exploiting the temporal correlation between consecutive frames and makes it possible to perform more sophisticated detection at the beginning to improve the accuracy, followed by ultrafast sequential tracking after the initialization. The method was evaluated and validated using 1149 cine-MV images from two prostate IGRT patients and compared with manual marker detection results from six researchers. The average of the manual detection results is considered as the ground truth for comparisons. Results: The average root-mean-square errors of our real-time automatic tracking method from the ground truth are 1.9 and 2.1 pixels for the two patients (0.26 mm/pixel). The

  6. Quantitative contrast enhanced ultrasound of the liver for time intensity curves-Reliability and potential sources of errors.

    Science.gov (United States)

    Ignee, Andre; Jedrejczyk, Maciej; Schuessler, Gudrun; Jakubowski, Wieslaw; Dietrich, Christoph F

    2010-01-01

    Time intensity curves for real-time contrast enhanced low MI ultrasound is a promising technique since it adds objective data to the more subjective conventional contrast enhanced technique. Current developments showed that the amount of uptake in modern targeted therapy strategies correlates with therapy response. Nevertheless no basic research has been done concerning the reliability and validity of the method. Videos sequences of 31 consecutive patients for at least 60s were recorded. Parameters analysed: area under the curve, maximum intensity, mean transit time, perfusion index, time to peak, rise time. The influence of depth, lateral shift as well as size and shape of the region of interest was analysed. The parameters time to peak and rise time showed a good stability in different depths. Overall there was a variation >50% for all other parameters. Mean transit time, time to peak and rise time were stable from 3 to 10cm depths, whereas all other parameters showed only satisfying results at 4-6cm. Time to peak and rise time were stable as well against lateral shifting whereas all other parameters had again variations over 50%. Size and shape of the region of interest did not influence the results. (1) It is important to compare regions of interest, e.g. in a tumour vs. representative parenchyma in the same depths. (2) Time intensity curves should not be analysed in a depth of less than 4cm. (3) The parameters area under the curve, perfusion index and maximum intensity should not be analysed in a depth more than 6cm. (4) Size and shape of a region of interest in liver parenchyma do not affect time intensity curves. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  7. Quantitative contrast enhanced ultrasound of the liver for time intensity curves-Reliability and potential sources of errors

    Energy Technology Data Exchange (ETDEWEB)

    Ignee, Andre [Department of Internal Medicine and Diagnostic Imaging, Caritas Hospital, Uhlandstr. 7, 97990 Bad Mergentheim (Germany)], E-mail: andre.ignee@gmx.de; Jedrejczyk, Maciej [Department of Diagnostic Imaging, 2nd Division of Medical Faculty, Medical University, Ul. Kondratowicza 8, 03-242 Warsaw (Poland)], E-mail: mjedrzejczyk@interia.pl; Schuessler, Gudrun [Department of Internal Medicine and Diagnostic Imaging, Caritas Hospital, Uhlandstr. 7, 97990 Bad Mergentheim (Germany)], E-mail: gudrunschuessler@gmx.de; Jakubowski, Wieslaw [Department of Diagnostic Imaging, 2nd Division of Medical Faculty, Medical University, Ul. Kondratowicza 8, 03-242 Warsaw (Poland)], E-mail: ewajbmd@go2.pl; Dietrich, Christoph F. [Department of Internal Medicine and Diagnostic Imaging, Caritas Hospital, Uhlandstr. 7, 97990 Bad Mergentheim (Germany)], E-mail: christoph.dietrich@ckbm.de

    2010-01-15

    Introduction: Time intensity curves for real-time contrast enhanced low MI ultrasound is a promising technique since it adds objective data to the more subjective conventional contrast enhanced technique. Current developments showed that the amount of uptake in modern targeted therapy strategies correlates with therapy response. Nevertheless no basic research has been done concerning the reliability and validity of the method. Patients and methods: Videos sequences of 31 consecutive patients for at least 60 s were recorded. Parameters analysed: area under the curve, maximum intensity, mean transit time, perfusion index, time to peak, rise time. The influence of depth, lateral shift as well as size and shape of the region of interest was analysed. Results: The parameters time to peak and rise time showed a good stability in different depths. Overall there was a variation >50% for all other parameters. Mean transit time, time to peak and rise time were stable from 3 to 10 cm depths, whereas all other parameters showed only satisfying results at 4-6 cm. Time to peak and rise time were stable as well against lateral shifting whereas all other parameters had again variations over 50%. Size and shape of the region of interest did not influence the results. Discussion: (1) It is important to compare regions of interest, e.g. in a tumour vs. representative parenchyma in the same depths. (2) Time intensity curves should not be analysed in a depth of less than 4 cm. (3) The parameters area under the curve, perfusion index and maximum intensity should not be analysed in a depth more than 6 cm. (4) Size and shape of a region of interest in liver parenchyma do not affect time intensity curves.

  8. Quantitative contrast enhanced ultrasound of the liver for time intensity curves-Reliability and potential sources of errors

    International Nuclear Information System (INIS)

    Ignee, Andre; Jedrejczyk, Maciej; Schuessler, Gudrun; Jakubowski, Wieslaw; Dietrich, Christoph F.

    2010-01-01

    Introduction: Time intensity curves for real-time contrast enhanced low MI ultrasound is a promising technique since it adds objective data to the more subjective conventional contrast enhanced technique. Current developments showed that the amount of uptake in modern targeted therapy strategies correlates with therapy response. Nevertheless no basic research has been done concerning the reliability and validity of the method. Patients and methods: Videos sequences of 31 consecutive patients for at least 60 s were recorded. Parameters analysed: area under the curve, maximum intensity, mean transit time, perfusion index, time to peak, rise time. The influence of depth, lateral shift as well as size and shape of the region of interest was analysed. Results: The parameters time to peak and rise time showed a good stability in different depths. Overall there was a variation >50% for all other parameters. Mean transit time, time to peak and rise time were stable from 3 to 10 cm depths, whereas all other parameters showed only satisfying results at 4-6 cm. Time to peak and rise time were stable as well against lateral shifting whereas all other parameters had again variations over 50%. Size and shape of the region of interest did not influence the results. Discussion: (1) It is important to compare regions of interest, e.g. in a tumour vs. representative parenchyma in the same depths. (2) Time intensity curves should not be analysed in a depth of less than 4 cm. (3) The parameters area under the curve, perfusion index and maximum intensity should not be analysed in a depth more than 6 cm. (4) Size and shape of a region of interest in liver parenchyma do not affect time intensity curves.

  9. Contrast medium-enhanced MRI findings and changes over time in stage I tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Oztoprak, I. [Department of Radiology Cumhuriyet University Faculty of Medicine, 58140 Sivas (Turkey)], E-mail: oztoprak@cumhuriyet.edu.tr; Guemues, C.; Oztoprak, B. [Department of Radiology Cumhuriyet University Faculty of Medicine, 58140 Sivas (Turkey); Engin, A. [Department of Infectious Diseases, Cumhuriyet University Faculty of Medicine, Sivas (Turkey)

    2007-12-15

    Aim: To demonstrate the detailed imaging characteristics of early tuberculous meningitis (TBM) and changes over time on standard gadolinium-enhanced, T1-weighted magnetic resonance imaging (MRI) images. Materials and methods: Contrast-enhanced, T1-weighted, spin-echo MRI images of 26 patients with early TBM were evaluated retrospectively. Meningeal enhancement characteristics were categorized according to distribution and pattern as diffuse, focal, linear, nodular, and mixed. Results: We found that 35% of patients had diffuse meningeal enhancement and 65% of cases had focal meningeal enhancement. There was a predilection for focal meningeal enhancement in basal pial areas, the interpeduncular fossa being the most common. In six patients with diffuse meningeal enhancement admitted to hospital relatively early after the onset of symptoms, the type of meningeal enhancement later changed to the focal form. Conclusion: Reactive diffuse meningeal enhancement occurs in the early period of TBM on contrast medium-enhanced T1-weighted MR images, but later becomes limited to basal areas.

  10. Contrast medium-enhanced MRI findings and changes over time in stage I tuberculous meningitis

    International Nuclear Information System (INIS)

    Oztoprak, I.; Guemues, C.; Oztoprak, B.; Engin, A.

    2007-01-01

    Aim: To demonstrate the detailed imaging characteristics of early tuberculous meningitis (TBM) and changes over time on standard gadolinium-enhanced, T1-weighted magnetic resonance imaging (MRI) images. Materials and methods: Contrast-enhanced, T1-weighted, spin-echo MRI images of 26 patients with early TBM were evaluated retrospectively. Meningeal enhancement characteristics were categorized according to distribution and pattern as diffuse, focal, linear, nodular, and mixed. Results: We found that 35% of patients had diffuse meningeal enhancement and 65% of cases had focal meningeal enhancement. There was a predilection for focal meningeal enhancement in basal pial areas, the interpeduncular fossa being the most common. In six patients with diffuse meningeal enhancement admitted to hospital relatively early after the onset of symptoms, the type of meningeal enhancement later changed to the focal form. Conclusion: Reactive diffuse meningeal enhancement occurs in the early period of TBM on contrast medium-enhanced T1-weighted MR images, but later becomes limited to basal areas

  11. Real-time multiple image manipulations

    International Nuclear Information System (INIS)

    Arenson, J.S.; Shalev, S.; Legris, J.; Goertzen, Y.

    1984-01-01

    There are many situations in which it is desired to manipulate two or more images under real-time operator control. The authors have investigated a number of such cases in order to determine their value and applicability in clinical medicine and laboratory research. Several examples are presented in detail. The DICOM-8 video image computer system was used due to its capability of storing two 512 x 512 x 8 bit images and operating on them, and/or an incoming video frame, with any of a number of real time operations including addition, subtraction, inversion, averaging, logical AND, NAND, OR, NOR, NOT, XOR and XNOR, as well as combinations of these. Some applications involve manipulations of or among the stored images. In others, a stored image is used as a mask or template for positioning or adjusting a second image to be grabbed via a video camera. The accuracy of radiotherapy treatment is verified by comparing port films with the original radiographic planning film, which is previously digitized and stored. Moving the port film on the light box while viewing the real-time subtraction image allows for adjustments of zoom, translation and rotation, together with contrast and edge enhancement

  12. Subtraction MR venography acquired from time-resolved contrast-enhanced MR angiography: Comparison with phase-contrast MR venography and single-phase contrast-enhanced MR venography

    International Nuclear Information System (INIS)

    Jang, Jin Hee; Kim, Bum Soo; KIm, Bom Yi; Choi, Hyun Seok; Jung, So Lyung; Ahn, Kook Jin; Sung, Ji Kyeong

    2015-01-01

    To evaluate the image characteristics of subtraction magnetic resonance venography (SMRV) from time-resolved contrast-enhanced MR angiography (TRMRA) compared with phase-contrast MR venography (PCMRV) and single-phase contrast-enhanced MR venography (CEMRV). Twenty-one patients who underwent brain MR venography (MRV) using standard protocols (PCMRV, CEMRV, and TRMRA) were included. SMRV was made by subtracting the arterial phase data from the venous phase data in TRMRA. Co-registration and subtraction of the two volume data was done using commercially available software. Image quality and the degree of arterial contamination of the three MRVs were compared. In the three MRVs, 19 pre-defined venous structures (14 dural sinuses and 5 cerebral veins) were evaluated. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the three MRVs were also compared. Single-phase contrast-enhanced MR venography showed better image quality (median score 4 in both reviewers) than did the other two MRVs (p < 0.001), whereas SMRV (median score 3 in both reviewers) and PCMRV (median score 3 in both reviewers) had similar image quality (p ≥ 0.951). SMRV (median score 0 in both reviewers) suppressed arterial signal better than did the other MRVs (median score 1 in CEMRV, median score 2 in PCMRV, both reviewers) (p < 0.001). The dural sinus score of SMRV (median and interquartile range [IQR] 48, 43-50 for reviewer 1, 47, 43-49 for reviewer 2) was significantly higher than for PCMRV (median and IQR 31, 25-34 for reviewer 1, 30, 23-32 for reviewer 2) (p < 0.01) and did not differ from that of CEMRV (median and IQR 50, 47-52 for reviewer 1, 49, 45-51 for reviewer 2) (p = 0.146 in reviewer 1 and 0.123 in reviewer 2). The SNR and CNR of SMRV (median and IQR 104.5, 83.1-121.2 and 104.1, 74.9-120.5, respectively) were between those of CEMRV (median and IQR 150.3, 111-182.6 and 148.4, 108-178.2) and PCMRV (median and IQR 59.4, 49.2-74.9 and 53.6, 43.8-69.2). Subtraction magnetic

  13. Comparison of transient arterial occlusion and muscle exercise provocation for assessment of perfusion reserve in skeletal muscle with real-time contrast-enhanced ultrasound

    International Nuclear Information System (INIS)

    Krix, Martin; Krakowski-Roosen, Holger; Armarteifio, Erick; Fuerstenberger, Susanne; Delorme, Stefan; Kauczor, Hans-Ulrich; Weber, Marc-Andre

    2011-01-01

    Objective: Contrast-enhanced ultrasound (CEUS) is able to quantify muscle perfusion and changes in perfusion due to muscle exercise in real-time. However, reliable measurement of standardized muscle exercise is difficult to perform in clinical examinations. We compared perfusion reserve assessed by CEUS after transient arterial occlusion and exercise to find the most suitable measurement for clinical application. Methods: Contrast pulse sequencing (7 MHz) during continuous IV infusion of SonoVue (4.8 mL/300 s) was used in 8 healthy volunteers to monitor muscle perfusion of the gastrocnemius muscle during transient (1 min) arterial occlusion produced by a thigh cuff of a venous occlusion plethysmograph. Isometric muscle exercise (50% of individual maximum strength for 20 s) was subsequently performed during the same examination, and several CEUS parameters obtained from ultrasound-signal-intensity-time curves and its calculation errors were compared. Results: The mean maximum local blood volume after occlusion was 13.9 [∼mL] (range, 4.5-28.8 [∼mL]), and similar values were measured after sub-maximum exercise 13.8 [∼mL], (range, 4.6-22.2 [∼mL]. The areas under the curve during reperfusion vs. recovery were also similar (515.2 ± 257.5 compared to 482.2 ± 187.5 [∼mL s]) with a strong correlation (r = 0.65), as were the times to maximum (15.3 s vs. 15.9 s), with a significantly smaller variation for the occlusion method (±2.1 s vs. ±9.0 s, p = 0.03). The mean errors for all calculated CEUS parameters were lower for the occlusion method than for the exercise test. Conclusions: CEUS muscle perfusion measurements can be easily performed after transient arterial occlusion. It delivers data which are comparable to CEUS measurements after muscle exercise but with a higher robustness. This method can be easily applied in clinical examination of patients with e.g. PAOD or diabetic microvessel diseases to assess perfusion reserve.

  14. Contrast-enhanced ultrasound for diagnosis of prostate cancer and kidney lesions

    International Nuclear Information System (INIS)

    Mitterberger, Michael; Pelzer, Alexandre; Colleselli, Daniela; Bartsch, Georg; Strasser, Hannes; Pallwein, Leo; Aigner, Friedrich; Gradl, Johann; Frauscher, Ferdinand

    2007-01-01

    Purpose of review: Conventional ultrasonography of both, kidney and prostate, is limited due to the poor contrast of B-mode imaging for parenchymal disease and limited sensitivity of colour Doppler for the detection of capillaries and deep pedicular vessels. Contrast-enhanced ultrasound (CEUS) overcomes these limitations. Recent findings: CEUS investigates the blood flow of the prostate, allows for prostate cancer visualization and for targeted biopsies. Comparisons between systematic and CEUS-targeted biopsies have shown that the targeted approach detects more cancers with a lower number of biopsy cores and with higher Gleason scores compared with the systematic approach. Also the kidney offers promising applications as CEUS improves the detection of abnormal microvascular and macrovascular disorders. Summary: In recent literature CEUS has shown its value for diagnosis of both, prostate cancer and kidney lesions. This paper describes recent improvements and future perspectives of CEUS

  15. Breast Dynamic Contrast Enhanced MRI: Fibrocystic Changes Presenting as a Non-mass Enhancement Mimicking Malignancy.

    Science.gov (United States)

    Milosevic, Zorica C; Nadrljanski, Mirjan M; Milovanovic, Zorka M; Gusic, Nina Z; Vucicevic, Slavko S; Radulovic, Olga S

    2017-06-01

    We aimed to analyse the morphokinetic features of breast fibrocystic changes (nonproliferative lesions, proliferative lesions without atypia and proliferative lesions with atypia) presenting as a non-mass enhancement (NME)in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) examination. Forty-six patients with histologically proven fibrocystic changes (FCCs) were retrospectively reviewed, according to Breast Imaging Reporting and Data System (BI-RADS) lexicon. Prior to DCE-MRI examination, a unilateral breast lesion suspicious of malignancy was detected clinically, on mammography or breast ultrasonography. The predominant features of FCCs presenting as NME in DCE-MRI examination were: unilateral regional or diffuse distribution (in 35 patients or 76.1%), heterogeneous or clumped internal pattern of enhancement (in 36 patients or 78.3%), plateau time-intensity curve (in 25 patients or 54.3%), moderate or fast wash-in (in 31 patients or 67.4%).Nonproliferative lesions were found in 11 patients (24%), proliferative lesions without atypia in 29 patients (63%) and lesions with atypia in six patients (13%), without statistically significant difference of morphokinetic features, except of the association of clustered microcysts with proliferative dysplasia without atypia. FCCs presenting as NME in DCE-MRI examination have several morphokinetic features suspicious of malignancy, therefore requiring biopsy (BI-RADS 4). Nonproliferative lesions, proliferative lesions without atypia and proliferative lesions with atypia predominantly share the same predefined DCE-MRI morphokinetic features.

  16. Effect of obstructive jaundice on hepatic hemodynamics: use of Sonazoid-enhanced ultrasonography in a prospective study of the blood flow balance between the hepatic portal vein and hepatic artery.

    Science.gov (United States)

    Wakui, Noritaka; Takeda, Yuki; Nishinakagawa, Shuta; Ueki, Nobuo; Otsuka, Takafumi; Oba, Nobuyuki; Hashimoto, Hiroshi; Kamiyama, Naohisa; Sumino, Yasukiyo; Kojima, Tatsuya

    2015-10-01

    To prospectively clarify the effects of obstructive jaundice (OJ) on hepatic hemodynamics using contrast-enhanced ultrasonography (US). Subjects comprised 14 patients admitted to our hospital for OJ between April 2013 and March 2014. Contrast-enhanced US was performed using the LOGIQ E9 ultrasound device during the jaundice phase, before biliary drainage, and again after improvement of jaundice. After injecting the Sonazoid contrast agent, contrast dynamics were recorded in the right kidney and liver segments 5 or 6. Prototype software was used to calculate mean arrival time (AT) of the contrast agent in the liver parenchyma. Statistical analysis was performed to compare the mean AT in the jaundice and improved jaundice phases. We were unable to follow up three of the 14 patients after biliary drainage; thus, we included 11 patients for further analysis. The mean AT of the contrast agent was 2.0 ± 1.8 and 6.1 ± 2.3 s in the jaundice and improved jaundice phases, respectively, showing significantly shorter AT in the jaundice phase (p = 0.0033). Our findings indicate that OJ may influence the blood flow balance between the hepatic portal vein and hepatic artery.

  17. Neurofeedback using real-time near-infrared spectroscopy enhances motor imagery related cortical activation.

    Directory of Open Access Journals (Sweden)

    Masahito Mihara

    Full Text Available Accumulating evidence indicates that motor imagery and motor execution share common neural networks. Accordingly, mental practices in the form of motor imagery have been implemented in rehabilitation regimes of stroke patients with favorable results. Because direct monitoring of motor imagery is difficult, feedback of cortical activities related to motor imagery (neurofeedback could help to enhance efficacy of mental practice with motor imagery. To determine the feasibility and efficacy of a real-time neurofeedback system mediated by near-infrared spectroscopy (NIRS, two separate experiments were performed. Experiment 1 was used in five subjects to evaluate whether real-time cortical oxygenated hemoglobin signal feedback during a motor execution task correlated with reference hemoglobin signals computed off-line. Results demonstrated that the NIRS-mediated neurofeedback system reliably detected oxygenated hemoglobin signal changes in real-time. In Experiment 2, 21 subjects performed motor imagery of finger movements with feedback from relevant cortical signals and irrelevant sham signals. Real neurofeedback induced significantly greater activation of the contralateral premotor cortex and greater self-assessment scores for kinesthetic motor imagery compared with sham feedback. These findings suggested the feasibility and potential effectiveness of a NIRS-mediated real-time neurofeedback system on performance of kinesthetic motor imagery. However, these results warrant further clinical trials to determine whether this system could enhance the effects of mental practice in stroke patients.

  18. Ileal Crohn disease: mural microvascularity quantified with contrast-enhanced US correlates with disease activity.

    Science.gov (United States)

    De Franco, Antonio; Di Veronica, Alessandra; Armuzzi, Alessandro; Roberto, Italia; Marzo, Manuela; De Pascalis, Barbara; De Vitis, Italo; Papa, Alfredo; Bock, Enrico; Danza, Francesco M; Bonomo, Lorenzo; Guidi, Luisa

    2012-02-01

    To quantitatively assess microvascular activation in the thickened ileal walls of patients with Crohn disease (CD) by using contrast-enhanced ultrasonography (US) and evaluate its correlation with widely used indexes of CD activity. This prospective study was approved by the ethics committee, and written informed consent was obtained from all patients. The authors examined 54 consecutively enrolled patients (mean age, 35.29 years; age range, 18-69 years; 39 men, 15 women) with endoscopically confirmed CD of the terminal ileum. Ileal wall segments thicker than 3 mm were examined with low-mechanical-index contrast-enhanced US and a second-generation US contrast agent. The authors analyzed software-plotted time-enhancement intensity curves to determine the maximum peak intensity (MPI) and wash-in slope coefficient (β) and evaluated their correlation with (a) the composite index of CD activity (CICDA), (b) the CD activity index (CDAI), and (c) the simplified endoscopic score for CD (SES-CD, evaluated in 37 patients) for the terminal ileum. Statistical analysis was performed with the Mann-Whitney test, Spearman rank test, and receiver operating characteristic (ROC) analysis. MPI and β coefficients were significantly increased in the 36 patients with a CICDA indicative of active disease (P<.0001 for both), the 33 patients with a CDAI of at least 150 (P<.032 and P<.0074, respectively), and the 26 patients with an SES-CD of at least 1 (P<.0001 and P<.002, respectively). ROC analysis revealed accurate identification (compared with CICDA) of active CD with an MPI threshold of 24 video intensity (VI) (sensitivity, 97%; specificity, 83%) and a β coefficient of 4.5 VI/sec (sensitivity, 86%; specificity, 83%). Contrast-enhanced US of the ileal wall is a promising method for objective, reproducible assessment of disease activity in patients with ileal CD. © RSNA, 2011

  19. Harmonic Contrast-Enhanced Endoscopic Ultrasonography for the Guidance of Fine-Needle Aspiration in Solid Pancreatic Masses

    DEFF Research Database (Denmark)

    Seicean, A; Badea, R; Moldovan-Pop, A

    2015-01-01

    Purpose: The global accuracy of fine-needle aspiration guided by endoscopic ultrasound (EUS-FNA) for pancreatic adenocarcinoma is about 85 %. The use of contrast agents during EUS to highlight vessels and the necrotic parts of pancreatic masses may improve biopsy guidance. Our aim was to assess...... whether the guidance of FNA by harmonic contrast-enhanced endoscopic ultrasound (CH-EUS) would increase diagnostic accuracy relative to conventional EUS-FNA in the same pancreatic masses. Patients and Methods: In a prospective study, EUS-FNA was performed in patients with pancreatic masses on CT scan......, followed by harmonic CH-EUS using SonoVue. A second cluster of CH-EUS-FNA was performed on contrast-enhanced images. The final diagnosis was based on the results of EUS-FNA and surgery, or the findings after 12 months' follow-up. Results: The final diagnosis was adenocarcinoma (n = 35), chronic...

  20. Ultrasonography versus intravenous urography

    International Nuclear Information System (INIS)

    Aslaksen, A.

    1991-01-01

    The present study was performed to compare the clinical value of urography and ultrasonography in a non-selected group of patients referred for urography to a university hospital. The conslusions and clinical implications of the study are as follows: Intravenous urography remains the cornerstone imaging examination in the evaluation of ureteral calculi. Ultrasonography is a valuable adjunct in cases of non- visualization of the kidneys, in distal obstruction and known contrast media allergy. When women with recurrent urinary tract infection are referred for imaging of the urinary tract, ultrasonography should be used. Ultrasonography should replace urography for screening of non-acute hydronephrosis like in female genital cancer and benign prostate hyperplasia. There is good correlation between urography and ultrasonography in assessing the degree of hydronephrosis. However, more researh on the relationship between hydronephrosis and obstruction is necessary. Ultrasonography should be used as the only imaging method of the upper urinary tract in patients with microscopic hematuria. In patients less than 50 years with macroscopic hematuria, ultrasonography should be used as the only imaging of the upper urinary tract, and an examination of the urinary bladder should be included. In patients over 50 years, urography supplied with ultrasonography should be used, but more research is necessary on the subject of imaging method and age. 158 refs

  1. Diagnosing upper extremity deep vein thrombosis with non-contrast-enhanced Magnetic Resonance Direct Thrombus Imaging: A pilot study.

    Science.gov (United States)

    Dronkers, C E A; Klok, F A; van Haren, G R; Gleditsch, J; Westerlund, E; Huisman, M V; Kroft, L J M

    2018-03-01

    Diagnosing upper extremity deep vein thrombosis (UEDVT) can be challenging. Compression ultrasonography is often inconclusive because of overlying anatomic structures that hamper compressing veins. Contrast venography is invasive and has a risk of contrast allergy. Magnetic Resonance Direct Thrombus Imaging (MRDTI) and Three Dimensional Turbo Spin-echo Spectral Attenuated Inversion Recovery (3D TSE-SPAIR) are both non-contrast-enhanced Magnetic Resonance Imaging (MRI) sequences that can visualize a thrombus directly by the visualization of methemoglobin, which is formed in a fresh blood clot. MRDTI has been proven to be accurate in diagnosing deep venous thrombosis (DVT) of the leg. The primary aim of this pilot study was to test the feasibility of diagnosing UEDVT with these MRI techniques. MRDTI and 3D TSE-SPAIR were performed in 3 pilot patients who were already diagnosed with UEDVT by ultrasonography or contrast venography. In all patients, UEDVT diagnosis could be confirmed by MRDTI and 3D TSE-SPAIR in all vein segments. In conclusion, this study showed that non-contrast MRDTI and 3D TSE-SPAIR sequences may be feasible tests to diagnose UEDVT. However diagnostic accuracy and management studies have to be performed before these techniques can be routinely used in clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Real-time shadows

    CERN Document Server

    Eisemann, Elmar; Assarsson, Ulf; Wimmer, Michael

    2011-01-01

    Important elements of games, movies, and other computer-generated content, shadows are crucial for enhancing realism and providing important visual cues. In recent years, there have been notable improvements in visual quality and speed, making high-quality realistic real-time shadows a reachable goal. Real-Time Shadows is a comprehensive guide to the theory and practice of real-time shadow techniques. It covers a large variety of different effects, including hard, soft, volumetric, and semi-transparent shadows.The book explains the basics as well as many advanced aspects related to the domain

  3. Contrast-enhanced power Doppler US of hepatocellular carcinomas: Quantitative analysis

    International Nuclear Information System (INIS)

    Kim, Ah Young; Choi, Byung Ihn; Kim, Tae Kyoung; Lee, Kyoung Ho; Han, Joon Koo

    1999-01-01

    To determine peak time and duration of contrast enhancement of nodular hepatocellular carcinoma (HCC) on contrast-enhancement power Doppler ultrasound (US) with Levovist by quantitative analysis. Twenty eight patients with nodular HCC were prospectively evaluated with power Doppler US by one examiner. Serial images were obtained before and after injection of 300 mg/mL US contrast agent (SH U 508 A, Levovist, Schering) with the injection rate of 0.2 mL/sec. Power Doppler signals on obtained digital images were quantified using 'Ultrasound Imaging Tool Version 1.0' (Seoul, Korea). The grade, peak time and duration of contrast enhancement of the tumors were analyzed. For nodular HCCs, mean peak enhancement time was 60 seconds after injection of Levovist (mean enhanced area 41.6 ± 28.6 %). These tumoral enhancement decreased from 90 seconds and returned to near baseline state at 5 minutes after injection of Levovist. Maximum enhanced areas (%) were variable at a range of 8-98.5% and mean maximum enhanced area was 46.4 ± 28.6%. On contrast-enhanced power Doppler US with Levovist, nodular HCCs showed peak contrast enhancement (41.6± 28.6) at 60 seconds after injection of contrast agent. This tumoral enhancement nearly disappeared at 5 minutes after injection of contrast agent.

  4. Comparison of Contrast-Enhanced Ultrasound and Computed Tomography in Classifying Endoleaks After Endovascular Treatment of Abdominal Aorta Aneurysms: Preliminary Experience

    International Nuclear Information System (INIS)

    Carrafiello, Gianpaolo; Lagana, Domenico; Recaldini, Chiara; Mangini, Monica; Bertolotti, Elena; Caronno, Roberto; Tozzi, Matteo; Piffaretti, Gabriele; Annibale Genovese, Eugenio; Fugazzola, Carlo

    2006-01-01

    The purpose of the study was to assess the effectiveness of contrast-enhanced ultrasonography (CEUS) in endoleak classification after endovascular treatment of an abdominal aortic aneurysm compared to computed tomography angiography (CTA). From May 2001 to April 2003, 10 patients with endoleaks already detected by CTA underwent CEUS with Sonovue (registered) to confirm the CTA classification or to reclassify the endoleak. In three conflicting cases, the patients were also studied with conventional angiography. CEUS confirmed the CTA classification in seven cases (type II endoleaks). Two CTA type III endoleaks were classified as type II using CEUS and one CTA type II endoleak was classified as type I by CEUS. Regarding the cases with discordant classification, conventional angiography confirmed the ultrasound classification. Additionally, CEUS documented the origin of type II endoleaks in all cases. After CEUS reclassification of endoleaks, a significant change in patient management occurred in three cases. CEUS allows a better attribution of the origin of the endoleak, as it shows the flow in real time. CEUS is more specific than CTA in endoleak classification and gives more accurate information in therapeutic planning

  5. Tracer kinetic model-driven registration for dynamic contrast-enhanced MRI time-series data.

    Science.gov (United States)

    Buonaccorsi, Giovanni A; O'Connor, James P B; Caunce, Angela; Roberts, Caleb; Cheung, Sue; Watson, Yvonne; Davies, Karen; Hope, Lynn; Jackson, Alan; Jayson, Gordon C; Parker, Geoffrey J M

    2007-11-01

    Dynamic contrast-enhanced MRI (DCE-MRI) time series data are subject to unavoidable physiological motion during acquisition (e.g., due to breathing) and this motion causes significant errors when fitting tracer kinetic models to the data, particularly with voxel-by-voxel fitting approaches. Motion correction is problematic, as contrast enhancement introduces new features into postcontrast images and conventional registration similarity measures cannot fully account for the increased image information content. A methodology is presented for tracer kinetic model-driven registration that addresses these problems by explicitly including a model of contrast enhancement in the registration process. The iterative registration procedure is focused on a tumor volume of interest (VOI), employing a three-dimensional (3D) translational transformation that follows only tumor motion. The implementation accurately removes motion corruption in a DCE-MRI software phantom and it is able to reduce model fitting errors and improve localization in 3D parameter maps in patient data sets that were selected for significant motion problems. Sufficient improvement was observed in the modeling results to salvage clinical trial DCE-MRI data sets that would otherwise have to be rejected due to motion corruption. Copyright 2007 Wiley-Liss, Inc.

  6. The value of contrast-enhanced laparoscopic ultrasound during robotic-assisted surgery for primary colorectal cancer

    DEFF Research Database (Denmark)

    Ellebaek, Signe Bremholm; Fristrup, Claus Wilki; Pless, Torsten

    2018-01-01

    AIM: The aim of this study was to assess the potential clinical value of contrast enhanced laparoscopic ultrasonography (CE-LUS) as a screening modality for liver metastases during robotic assisted surgery for primary colorectal cancer (CRC). METHOD: A prospective, descriptive (feasibility) study...... including 50 consecutive patients scheduled for robotic assisted surgery for primary CRC. CE-LUS was performed by 2 experienced specialists. Only patients without metastatic disease were included. Follow-up was obtained with contrast-enhanced CT imaging at 3 and 12 months postoperatively. RESULTS: Fifty......-up revealed no liver metastasis in any of the patients. CONCLUSION: CE-LUS did not increase the detection rate of occult liver metastasis during robotic assisted primary CRC surgery. The use of CE-LUS as a screening modality for detection of liver metastasis cannot be recommended based on this study...

  7. Hepatic Vein Arrival Time for Diagnosis of Liver Cirrhosis: A 10-Year Single-Center Experience With Contrast-Enhanced Sonography.

    Science.gov (United States)

    Abbattista, Teresa; Ridolfi, Francesco; Consalvo, Giovanni Traina; Brunelli, Eugenio

    2016-10-01

    To evaluate the performance of contrast-enhanced sonography with a second-generation contrast agent in assessing the severity of chronic diffuse liver disease and differentiating cirrhotic from noncirrhotic liver disease. Contrast-enhanced sonography was performed after intravenous bolus injection of a second-generation contrast agent in 14 healthy control participants and 160 consecutive patients with cirrhotic and noncirrhotic liver disease (n = 78 and 82, respectively) enrolled between March 2004 and April 2014. The intensity of enhancement in a main hepatic vein was used to determine hepatic vein arrival time, time to peak intensity, and peak contrast enhancement. The hepatic vein arrival time was lower in cirrhotic patients compared with both noncirrhotic patients and controls (mean ± SD, 15.0 ± 2.8, 21.5 ± 3.4, and 25.6 ± 4.7 seconds, respectively; P < .05). The hepatic vein arrival time in noncirrhotic patients was also significantly lower than that in controls (P < .05). The time to peak intensity was significantly lower in cirrhotic patients compared with noncirrhotic patients and controls (40.7 ± 13.7, 49.4 ± 12.8, and 51.2 ± 13.7 seconds; P < .05). A receiver operating characteristic curve analysis revealed that the hepatic vein arrival time more accurately excluded a diagnosis of liver cirrhosis than the time to peak intensity (area under the receiver operating characteristic curve, 0.953 versus 0.694). Specifically, a hepatic vein arrival time cutoff value of 17 seconds excluded liver cirrhosis with 91.1% sensitivity and 93.6% specificity. Contrast-enhanced sonography is a valid alternative method for noninvasive staging of liver diseases. The hepatic vein arrival time could be used to exclude liver cirrhosis in a clinical setting.

  8. Contrast-enhanced ultrasound in the diagnosis of nodules in liver cirrhosis.

    Science.gov (United States)

    Kim, Tae Kyoung; Jang, Hyun-Jung

    2014-04-07

    Contrast-enhanced ultrasound (CEUS) using microbubble contrast agents are useful for the diagnosis of the nodules in liver cirrhosis. CEUS can be used as a problem-solving method for indeterminate nodules on computed tomography (CT) or magnetic resonance imaging (MRI) or as an initial diagnostic test for small newly detected liver nodules. CEUS has unique advantages over CT and MRI including no renal excretion of contrast, real-time imaging capability, and purely intravascular contrast. Hepatocellular carcinoma (HCC) is characterized by arterial-phase hypervascularity and later washout (negative enhancement). Benign nodules such as regenerative nodules or dysplastic nodules are usually isoechoic or slightly hypoechoic in the arterial phase and isoechoic in the late phase. However, there are occasional HCC lesions with atypical enhancement including hypovascular HCC and hypervascular HCC without washout. Cholangiocarcinomas are infrequently detected during HCC surveillance and mostly show rim-like or diffuse hypervascularity followed by rapid washout. Hemangiomas are often found at HCC surveillance and are easily diagnosed by CEUS. CEUS can be effectively used in the diagnostic work-up of small nodules detected at HCC surveillance. CEUS is also useful to differentiate malignant and benign venous thrombosis and to guide and monitor the local ablation therapy for HCC.

  9. PixonVision real-time video processor

    Science.gov (United States)

    Puetter, R. C.; Hier, R. G.

    2007-09-01

    PixonImaging LLC and DigiVision, Inc. have developed a real-time video processor, the PixonVision PV-200, based on the patented Pixon method for image deblurring and denoising, and DigiVision's spatially adaptive contrast enhancement processor, the DV1000. The PV-200 can process NTSC and PAL video in real time with a latency of 1 field (1/60 th of a second), remove the effects of aerosol scattering from haze, mist, smoke, and dust, improve spatial resolution by up to 2x, decrease noise by up to 6x, and increase local contrast by up to 8x. A newer version of the processor, the PV-300, is now in prototype form and can handle high definition video. Both the PV-200 and PV-300 are FPGA-based processors, which could be spun into ASICs if desired. Obvious applications of these processors include applications in the DOD (tanks, aircraft, and ships), homeland security, intelligence, surveillance, and law enforcement. If developed into an ASIC, these processors will be suitable for a variety of portable applications, including gun sights, night vision goggles, binoculars, and guided munitions. This paper presents a variety of examples of PV-200 processing, including examples appropriate to border security, battlefield applications, port security, and surveillance from unmanned aerial vehicles.

  10. Intravenous contrast-enhanced sonography in children and adolescents – a single center experience

    Directory of Open Access Journals (Sweden)

    Martin Stenzel

    2013-06-01

    Full Text Available Compared to adult patients, ultrasonography in children and adolescents is much more common, due to lack of ionizing radiation, and its wide availability. With the introduction of contrast-media for use in ultrasonography, one major drawback of the method could be overcome. In Europe, SonoVue® is the only widely available agent, which due to improved stability makes it possible to image normal and diseased tissue perfusion and vascularization with high accuracy. Inability to hold the breath and voluntary body movement of the patient is less of an obstacle compared to color Doppler techniques and makes the method very attractive for use in children, which, depending on age, may not be very cooperative. Use of intravenous contrast-medium in minors is currently very limited for several reasons: availability, lack of recommendation in national and international guidelines, and lack of official licensing. The article will touch medical indications, technique, safety considerations, and perspective of intravenous use of contrast-media in children and adolescents, including data from a 6-year period in 37 patients. Purpose: The purpose of the study was to collect data on ultrasonographic examinations, expanded by intravenous administration of the contrast agent SonoVue® in children and adolescents. Besides assessing diagnostic yield, data on adverse medication effects was collected. Materials and methods: The study includes contrast-enhanced ultrasound examinations in 37 children at a single institution. Indications for the examinations were tumor lesions, infections, traumatic organ injuries, and parenchymal organ ischemia. Parents of the patients and adolescent patients were informed about the off-label use of the contrast agent. Thirty-nine examinations were performed, the average age of the patient was 11.1 years (range 1 7/ 12 to 17 11/ 12 years. Results: All of the examinations yielded additional diagnostic value, always expanding results

  11. Correlation of contrast agent kinetics between iodinated contrast-enhanced spectral tomosynthesis and gadolinium-enhanced MRI of breast lesions

    International Nuclear Information System (INIS)

    Froeling, Vera; Diekmann, Felix; Renz, Diane M.; Fallenberg, Eva M.; Steffen, Ingo G.; Diekmann, Susanne; Schmitzberger, Florian F.; Lawaczeck, Ruediger

    2013-01-01

    Assessment of contrast agent kinetics in contrast-enhanced MRI (CE-MRI) with gadolinium-containing contrast agents offers the opportunity to predict breast lesion malignancy. The goal of our study was to determine if similar patterns exist for spectral contrast-enhanced digital breast tomosynthesis (CE-DBT) using an iodinated contrast agent. The protocol of our prospective study was approved by the relevant institutional review board and the German Federal Office for Radiation Protection. All patients provided written informed consent. We included 21 women with a mean age of 62.4 years. All underwent ultrasound-guided biopsy of a suspect breast lesion, spectral CE-DBT and CE-MRI. For every breast lesion, contrast agent kinetics was assessed by signal intensity-time curves for spectral CE-DBT and CE-MRI. Statistical comparison used Cohen's kappa and Spearman's rho test. Spearman's rho of 0.49 showed significant (P = 0.036) correlation regarding the contrast agent kinetics in signal intensity-time curves for spectral CE-DBT and CE-MRI. Cohen's kappa indicated moderate agreement (kappa = 0.438). There is a statistically significant correlation between contrast agent kinetics in the signal intensity-time curves for spectral CE-DBT and CE-MRI. Observing intralesional contrast agent kinetics in spectral CE-DBT may aid evaluation of malignant breast lesions. (orig.)

  12. Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography.

    Science.gov (United States)

    Zhang, Tao; Yousaf, Ufra; Hsiao, Albert; Cheng, Joseph Y; Alley, Marcus T; Lustig, Michael; Pauly, John M; Vasanawala, Shreyas S

    2015-10-01

    Pediatric contrast-enhanced MR angiography is often limited by respiration, other patient motion and compromised spatiotemporal resolution. To determine the reliability of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography method for depicting abdominal arterial anatomy in young children. With IRB approval and informed consent, we retrospectively identified 27 consecutive children (16 males and 11 females; mean age: 3.8 years, range: 14 days to 8.4 years) referred for contrast-enhanced MR angiography at our institution, who had undergone free-breathing spatiotemporally accelerated time-resolved contrast-enhanced MR angiography studies. A radio-frequency-spoiled gradient echo sequence with Cartesian variable density k-space sampling and radial view ordering, intrinsic motion navigation and intermittent fat suppression was developed. Images were reconstructed with soft-gated parallel imaging locally low-rank method to achieve both motion correction and high spatiotemporal resolution. Quality of delineation of 13 abdominal arteries in the reconstructed images was assessed independently by two radiologists on a five-point scale. Ninety-five percent confidence intervals of the proportion of diagnostically adequate cases were calculated. Interobserver agreements were also analyzed. Eleven out of 13 arteries achieved acceptable image quality (mean score range: 3.9-5.0) for both readers. Fair to substantial interobserver agreement was reached on nine arteries. Free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography frequently yields diagnostic image quality for most abdominal arteries in young children.

  13. Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Tao; Cheng, Joseph Y. [Stanford University, Department of Radiology, Stanford, CA (United States); Stanford University, Department of Electrical Engineering, Stanford, CA (United States); Yousaf, Ufra; Alley, Marcus T.; Vasanawala, Shreyas S. [Stanford University, Department of Radiology, Stanford, CA (United States); Hsiao, Albert [University of California, San Diego, Department of Radiology, San Diego, CA (United States); Lustig, Michael [Stanford University, Department of Electrical Engineering, Stanford, CA (United States); University of California, Berkeley, Department of Electrical Engineering and Computer Sciences, Berkeley, CA (United States); Pauly, John M. [Stanford University, Department of Electrical Engineering, Stanford, CA (United States)

    2015-10-15

    Pediatric contrast-enhanced MR angiography is often limited by respiration, other patient motion and compromised spatiotemporal resolution. To determine the reliability of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography method for depicting abdominal arterial anatomy in young children. With IRB approval and informed consent, we retrospectively identified 27 consecutive children (16 males and 11 females; mean age: 3.8 years, range: 14 days to 8.4 years) referred for contrast-enhanced MR angiography at our institution, who had undergone free-breathing spatiotemporally accelerated time-resolved contrast-enhanced MR angiography studies. A radio-frequency-spoiled gradient echo sequence with Cartesian variable density k-space sampling and radial view ordering, intrinsic motion navigation and intermittent fat suppression was developed. Images were reconstructed with soft-gated parallel imaging locally low-rank method to achieve both motion correction and high spatiotemporal resolution. Quality of delineation of 13 abdominal arteries in the reconstructed images was assessed independently by two radiologists on a five-point scale. Ninety-five percent confidence intervals of the proportion of diagnostically adequate cases were calculated. Interobserver agreements were also analyzed. Eleven out of 13 arteries achieved acceptable image quality (mean score range: 3.9-5.0) for both readers. Fair to substantial interobserver agreement was reached on nine arteries. Free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography frequently yields diagnostic image quality for most abdominal arteries in young children. (orig.)

  14. Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography

    International Nuclear Information System (INIS)

    Zhang, Tao; Cheng, Joseph Y.; Yousaf, Ufra; Alley, Marcus T.; Vasanawala, Shreyas S.; Hsiao, Albert; Lustig, Michael; Pauly, John M.

    2015-01-01

    Pediatric contrast-enhanced MR angiography is often limited by respiration, other patient motion and compromised spatiotemporal resolution. To determine the reliability of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography method for depicting abdominal arterial anatomy in young children. With IRB approval and informed consent, we retrospectively identified 27 consecutive children (16 males and 11 females; mean age: 3.8 years, range: 14 days to 8.4 years) referred for contrast-enhanced MR angiography at our institution, who had undergone free-breathing spatiotemporally accelerated time-resolved contrast-enhanced MR angiography studies. A radio-frequency-spoiled gradient echo sequence with Cartesian variable density k-space sampling and radial view ordering, intrinsic motion navigation and intermittent fat suppression was developed. Images were reconstructed with soft-gated parallel imaging locally low-rank method to achieve both motion correction and high spatiotemporal resolution. Quality of delineation of 13 abdominal arteries in the reconstructed images was assessed independently by two radiologists on a five-point scale. Ninety-five percent confidence intervals of the proportion of diagnostically adequate cases were calculated. Interobserver agreements were also analyzed. Eleven out of 13 arteries achieved acceptable image quality (mean score range: 3.9-5.0) for both readers. Fair to substantial interobserver agreement was reached on nine arteries. Free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography frequently yields diagnostic image quality for most abdominal arteries in young children. (orig.)

  15. Enhanced conjugation stability and blood circulation time of macromolecular gadolinium-DTPA contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Jenjob, Ratchapol [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of); Kun, Na [Department of Biotechnology, The Catholic University of Korea, 43 Jibong-ro, Wonmi-gu, Bucheon-si, Gyeonggi-do 420-743 (Korea, Republic of); Ghee, Jung Yeon [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Shen, Zheyu; Wu, Xiaoxia [Division of Functional Materials and Nano-Devices, Ningbo Institute of Materials Technology & Engineering (NIMTE), Chinese Academy of Sciences, 519 Zhuangshi Street, Zhenhai District, Ningbo, Zhejiang 315201 (China); Cho, Steve K., E-mail: scho@gist.ac.kr [Division of Liberal Arts and Science, GIST College, Gwangju Institute of Science and Technology, Gwangju 500-712 (Korea, Republic of); Lee, Don Haeng [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Department of Internal Medicine, School of Medicine, Inha University Hospital, Incheon 420-751 (Korea, Republic of); Yang, Su-Geun, E-mail: Sugeun.Yang@Inha.ac.kr [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of)

    2016-04-01

    In this study, we prepared macromolecular MR T1 contrast agent: pullulan-conjugated Gd diethylene triamine pentaacetate (Gd-DTPA-Pullulan) and estimated residual free Gd{sup 3+}, chelation stability in competition with metal ions, plasma and tissue pharmacokinetics, and abdominal MR contrast on rats. Residual free Gd{sup 3+} in Gd-DTPA-Pullulan was measured using colorimetric spectroscopy. The transmetalation of Gd{sup 3+} incubated with Ca{sup 2+} was performed by using a dialysis membrane (MWCO 100–500 Da) and investigated by ICP-OES. The plasma concentration profiles of Gd-DTPA-Pullulan were estimated after intravenous injection at a dose 0.1 mmol/kg of Gd. The coronal-plane abdominal images of normal rats were observed by MR imaging. The content of free Gd{sup 3+}, the toxic residual form, was less than 0.01%. Chelation stability of Gd-DTPA-Pullulan was estimated, and only 0.2% and 0.00045% of Gd{sup 3+} were released from Gd-DTPA-Pullulan after 2 h incubation with Ca{sup 2+} and Fe{sup 2+}, respectively. Gd-DTPA-Pullulan displayed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h), much longer than 0.11 h and 0.79 h of Gd-EOB-DTPA. Abdominal MR imaging showed Gd-DTPA-Pullulan maintained initial MR contrast for 30 min. The extended plasma half-life of Gd-DTPA-Pullulan probably allows the prolonged MR acquisition time in clinic with enhanced MR contrast. - Highlights: • Macromolecule (pullulan) conjugated Gd contrast agent (Gd-DTPA-Pullulan) showed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h) in comparison with Gd-EOB-DTPA • Gd-DTPA-pullulan T1 contrast agent exhibited strong chelation stability against Gd. • The extended blood circulation attributed the enhanced and prolonged MR contrast on abdominal region of rats. • The extended blood circulation may provide prolonged MR acquisition time window in clinics.

  16. Contrast Enhanced Ultrasound of the Kidneys: What Is It Capable of?

    Directory of Open Access Journals (Sweden)

    Demosthenes D. Cokkinos

    2013-01-01

    Full Text Available One of the many imaging uses of contrast enhanced ultrasound (CEUS is studying a wide variety of kidney pathology, due to its ability to detect microvascular blood flow in real time without affecting renal function. CEUS enables dynamic assessment and quantification of microvascularisation up to capillary perfusion. The objective of this paper is to briefly refresh basic knowledge of ultrasound (US contrast agents’ physical properties, to study technical details of CEUS scanning in the kidneys, and to review the commonest renal indications for CEUS, with imaging examples in comparison to baseline unenhanced US and computed tomography when performed. Safety matters and limitations of CEUS of the kidneys are also discussed.

  17. Temporal contrast enhancement and parametric imaging for the visualisation of time patterns in dynamic scintigraphic imaging

    International Nuclear Information System (INIS)

    Deconinck, F.; Bossuyt, A.; Lepoudre, R.

    1982-01-01

    Image contrast, photon noise and sampling frequency limit the visual extraction of relevant temporal information in scintigraphic image series. When the Unitation is mainly due to low temporal contrast, temporal contrast enhancement will strongly improve the perceptibility of time patterns in the series. When the limitation is due to photon noise and limited temporal sampling, parametric imaging by means of the Hadamard transform can visualise temporal patterns. (WU)

  18. Intraoperative Cerebral Glioma Characterization with Contrast Enhanced Ultrasound

    Directory of Open Access Journals (Sweden)

    Francesco Prada

    2014-01-01

    Full Text Available Background. Contrast enhanced ultrasound (CEUS is a dynamic and continuous modality providing real-time view of vascularization and flow distribution patterns of different organs and tumors. Nevertheless its intraoperative use for brain tumors visualization has been performed few times, and a thorough characterization of cerebral glioma had never been performed before. Aim. To perform the first characterization of cerebral glioma using CEUS and to possibly achieve an intraoperative differentiation of different gliomas. Methods. We performed CEUS in an off-label setting in 69 patients undergoing surgery for cerebral glioma. An intraoperative qualitative analysis was performed comparing iCEUS with B-mode imaging. A postprocedural semiquantitative analysis was then performed for each case, according to EFSUMB criteria. Results were related to histopathology. Results. We observed different CE patterns: LGG show a mild, dotted CE with diffuse appearance and slower, delayed arterial and venous phase. HGG have a high CE with a more nodular, nonhomogeneous appearance and fast perfusion patterns. Conclusion. Our study characterizes for the first time human brain glioma with CEUS, providing further insight regarding these tumors’ biology. CEUS is a fast, safe, dynamic, real-time, and economic tool that might be helpful during surgery in differentiating malignant and benign gliomas and refining surgical strategy.

  19. Max CAPR: high-resolution 3D contrast-enhanced MR angiography with acquisition times under 5 seconds.

    Science.gov (United States)

    Haider, Clifton R; Borisch, Eric A; Glockner, James F; Mostardi, Petrice M; Rossman, Phillip J; Young, Phillip M; Riederer, Stephen J

    2010-10-01

    High temporal and spatial resolution is desired in imaging of vascular abnormalities having short arterial-to-venous transit times. Methods that exploit temporal correlation to reduce the observed frame time demonstrate temporal blurring, obfuscating bolus dynamics. Previously, a Cartesian acquisition with projection reconstruction-like (CAPR) sampling method has been demonstrated for three-dimensional contrast-enhanced angiographic imaging of the lower legs using two-dimensional sensitivity-encoding acceleration and partial Fourier acceleration, providing 1mm isotropic resolution of the calves, with 4.9-sec frame time and 17.6-sec temporal footprint. In this work, the CAPR acquisition is further undersampled to provide a net acceleration approaching 40 by eliminating all view sharing. The tradeoff of frame time and temporal footprint in view sharing is presented and characterized in phantom experiments. It is shown that the resultant 4.9-sec acquisition time, three-dimensional images sets have sufficient spatial and temporal resolution to clearly portray arterial and venous phases of contrast passage. It is further hypothesized that these short temporal footprint sequences provide diagnostic quality images. This is tested and shown in a series of nine contrast-enhanced MR angiography patient studies performed with the new method.

  20. Clinical evaluation of contrast-enhanced digital mammography and contrast enhanced tomosynthesis--Comparison to contrast-enhanced breast MRI.

    Science.gov (United States)

    Chou, Chen-Pin; Lewin, John M; Chiang, Chia-Ling; Hung, Bao-Hui; Yang, Tsung-Lung; Huang, Jer-Shyung; Liao, Jia-Bin; Pan, Huay-Ben

    2015-12-01

    To compare the diagnostic accuracy of contrast-enhanced digital mammography (CEDM) and contrast-enhanced tomosynthesis (CET) to dynamic contrast enhanced breast MRI (DCE-MRI) using a multireader-multicase study. Institutional review board approval and informed consents were obtained. Total 185 patients (mean age 51.3) with BI-RADS 4 or 5 lesions were evaluated before biopsy with mammography, tomosynthesis, CEDM, CET and DCE-MRI. Mediolateral-oblique and cranio-caudal views of the target breast CEDM and CET were acquired at 2 and 4 min after contrast agent injection. A mediolateral-oblique view of the non-target breast was taken at 6 min. Each lesion was scored with forced BI-RADS categories by three readers. Each reader interpreted lesions in the following order: mammography, tomosynthesis, CEDM, CET, and DCE-MRI during a single reading session. Histology showed 81 cancers and 144 benign lesions in the study. Of the 81 malignant lesions, 44% (36/81) were invasive and 56% (45/81) were non-invasive. Areas under the ROC curve, averaged for the 3 readers, were as follows: 0.897 for DCE-MRI, 0.892 for CET, 0.878 for CEDM, 0.784 for tomosynthesis and 0.740 for mammography. Significant differences in AUC were found between the group of contrast enhanced modalities (CEDM, CET, DCE-MRI) and the unenhanced modalities (all p0.05). CET and CEDM may be considered as an alternative modality to MRI for following up women with abnormal mammography. All three contrast modalities were superior in accuracy to conventional digital mammography with or without tomosynthesis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Using dual-energy x-ray imaging to enhance automated lung tumor tracking during real-time adaptive radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Menten, Martin J., E-mail: martin.menten@icr.ac.uk; Fast, Martin F.; Nill, Simeon; Oelfke, Uwe, E-mail: uwe.oelfke@icr.ac.uk [Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London SM2 5NG (United Kingdom)

    2015-12-15

    Purpose: Real-time, markerless localization of lung tumors with kV imaging is often inhibited by ribs obscuring the tumor and poor soft-tissue contrast. This study investigates the use of dual-energy imaging, which can generate radiographs with reduced bone visibility, to enhance automated lung tumor tracking for real-time adaptive radiotherapy. Methods: kV images of an anthropomorphic breathing chest phantom were experimentally acquired and radiographs of actual lung cancer patients were Monte-Carlo-simulated at three imaging settings: low-energy (70 kVp, 1.5 mAs), high-energy (140 kVp, 2.5 mAs, 1 mm additional tin filtration), and clinical (120 kVp, 0.25 mAs). Regular dual-energy images were calculated by weighted logarithmic subtraction of high- and low-energy images and filter-free dual-energy images were generated from clinical and low-energy radiographs. The weighting factor to calculate the dual-energy images was determined by means of a novel objective score. The usefulness of dual-energy imaging for real-time tracking with an automated template matching algorithm was investigated. Results: Regular dual-energy imaging was able to increase tracking accuracy in left–right images of the anthropomorphic phantom as well as in 7 out of 24 investigated patient cases. Tracking accuracy remained comparable in three cases and decreased in five cases. Filter-free dual-energy imaging was only able to increase accuracy in 2 out of 24 cases. In four cases no change in accuracy was observed and tracking accuracy worsened in nine cases. In 9 out of 24 cases, it was not possible to define a tracking template due to poor soft-tissue contrast regardless of input images. The mean localization errors using clinical, regular dual-energy, and filter-free dual-energy radiographs were 3.85, 3.32, and 5.24 mm, respectively. Tracking success was dependent on tumor position, tumor size, imaging beam angle, and patient size. Conclusions: This study has highlighted the influence of

  2. Using dual-energy x-ray imaging to enhance automated lung tumor tracking during real-time adaptive radiotherapy

    International Nuclear Information System (INIS)

    Menten, Martin J.; Fast, Martin F.; Nill, Simeon; Oelfke, Uwe

    2015-01-01

    Purpose: Real-time, markerless localization of lung tumors with kV imaging is often inhibited by ribs obscuring the tumor and poor soft-tissue contrast. This study investigates the use of dual-energy imaging, which can generate radiographs with reduced bone visibility, to enhance automated lung tumor tracking for real-time adaptive radiotherapy. Methods: kV images of an anthropomorphic breathing chest phantom were experimentally acquired and radiographs of actual lung cancer patients were Monte-Carlo-simulated at three imaging settings: low-energy (70 kVp, 1.5 mAs), high-energy (140 kVp, 2.5 mAs, 1 mm additional tin filtration), and clinical (120 kVp, 0.25 mAs). Regular dual-energy images were calculated by weighted logarithmic subtraction of high- and low-energy images and filter-free dual-energy images were generated from clinical and low-energy radiographs. The weighting factor to calculate the dual-energy images was determined by means of a novel objective score. The usefulness of dual-energy imaging for real-time tracking with an automated template matching algorithm was investigated. Results: Regular dual-energy imaging was able to increase tracking accuracy in left–right images of the anthropomorphic phantom as well as in 7 out of 24 investigated patient cases. Tracking accuracy remained comparable in three cases and decreased in five cases. Filter-free dual-energy imaging was only able to increase accuracy in 2 out of 24 cases. In four cases no change in accuracy was observed and tracking accuracy worsened in nine cases. In 9 out of 24 cases, it was not possible to define a tracking template due to poor soft-tissue contrast regardless of input images. The mean localization errors using clinical, regular dual-energy, and filter-free dual-energy radiographs were 3.85, 3.32, and 5.24 mm, respectively. Tracking success was dependent on tumor position, tumor size, imaging beam angle, and patient size. Conclusions: This study has highlighted the influence of

  3. Using dual-energy x-ray imaging to enhance automated lung tumor tracking during real-time adaptive radiotherapy.

    Science.gov (United States)

    Menten, Martin J; Fast, Martin F; Nill, Simeon; Oelfke, Uwe

    2015-12-01

    Real-time, markerless localization of lung tumors with kV imaging is often inhibited by ribs obscuring the tumor and poor soft-tissue contrast. This study investigates the use of dual-energy imaging, which can generate radiographs with reduced bone visibility, to enhance automated lung tumor tracking for real-time adaptive radiotherapy. kV images of an anthropomorphic breathing chest phantom were experimentally acquired and radiographs of actual lung cancer patients were Monte-Carlo-simulated at three imaging settings: low-energy (70 kVp, 1.5 mAs), high-energy (140 kVp, 2.5 mAs, 1 mm additional tin filtration), and clinical (120 kVp, 0.25 mAs). Regular dual-energy images were calculated by weighted logarithmic subtraction of high- and low-energy images and filter-free dual-energy images were generated from clinical and low-energy radiographs. The weighting factor to calculate the dual-energy images was determined by means of a novel objective score. The usefulness of dual-energy imaging for real-time tracking with an automated template matching algorithm was investigated. Regular dual-energy imaging was able to increase tracking accuracy in left-right images of the anthropomorphic phantom as well as in 7 out of 24 investigated patient cases. Tracking accuracy remained comparable in three cases and decreased in five cases. Filter-free dual-energy imaging was only able to increase accuracy in 2 out of 24 cases. In four cases no change in accuracy was observed and tracking accuracy worsened in nine cases. In 9 out of 24 cases, it was not possible to define a tracking template due to poor soft-tissue contrast regardless of input images. The mean localization errors using clinical, regular dual-energy, and filter-free dual-energy radiographs were 3.85, 3.32, and 5.24 mm, respectively. Tracking success was dependent on tumor position, tumor size, imaging beam angle, and patient size. This study has highlighted the influence of patient anatomy on the success rate of real-time

  4. Initial evaluation of prostate cancer with real-time elastography based on step-section pathologic analysis after radical prostatectomy. A preliminary study

    International Nuclear Information System (INIS)

    Sumura, Masahiro; Shigeno, Kazushi; Hyuga, Taiju; Yoneda, Tatsuaki; Shiina, Hiroaki; Igawa, Mikio

    2007-01-01

    The objective of this study was to determine whether real-time elastography can be used to detect prostate cancer as a relatively non-invasive modality based on the tissue strain value. Seventeen patients underwent real-time elastography in conjunction with digital rectal examination (DRE), conventional gray-scale transrectal ultrasonography (TRUS), color Doppler ultrasonography (CDUS), and magnetic resonance imaging (MRI) prior to radical prostatectomy. The elastogram was compared to findings of conventional modalities and pathological findings of prostatectomy specimens. To obtain the elastogram, compression of the prostate was performed along with a visual indicator on a video screen. Twenty of 27 pathologically confirmed tumors were detected with real-time elastography. The cancer detection rate with real-time elastography was superior to the rates of other modalities and nearly equal to both on the anterior side (75.0%) and the posterior side (73.7%) of the prostate. A higher tumor detection rate for real-time elastography was observed for tumors with a higher Gleason score and larger tumor volume. In our preliminary study, real-time elastography in conjunction with gray-scale TRUS is a non-invasive modality to detect prostate cancer. (author)

  5. Real-time radiography

    International Nuclear Information System (INIS)

    Bossi, R.H.; Oien, C.T.

    1981-01-01

    Real-time radiography is used for imaging both dynamic events and static objects. Fluorescent screens play an important role in converting radiation to light, which is then observed directly or intensified and detected. The radiographic parameters for real-time radiography are similar to conventional film radiography with special emphasis on statistics and magnification. Direct-viewing fluoroscopy uses the human eye as a detector of fluorescent screen light or the light from an intensifier. Remote-viewing systems replace the human observer with a television camera. The remote-viewing systems have many advantages over the direct-viewing conditions such as safety, image enhancement, and the capability to produce permanent records. This report reviews real-time imaging system parameters and components

  6. Neurilemmoma of the glans penis: ultrasonography and magnetic resonance imaging findings.

    Science.gov (United States)

    Jung, Dae Chul; Hwang, Sung Il; Jung, Sung Il; Kim, Sun Ho; Kim, Seung Hyup

    2006-01-01

    Neurilemmoma of the glans penis is rare, and no imaging findings have been reported. A case of neurilemmoma of the glans penis is presented. Ultrasonography (US) and magnetic resonance imaging revealed a well-defined small mass in the glans penis. The mass appeared hypoechoic on gray-scale US and hypervascular on color Doppler US. Magnetic resonance imaging revealed high signal intensity of the mass on a T2-weighted image and strong enhancement on a contrast-enhanced T1-weighted image.

  7. Near Real-Time Browsable Landsat-8 Imagery

    Directory of Open Access Journals (Sweden)

    Cheng-Chien Liu

    2017-01-01

    Full Text Available The successful launch and operation of Landsat-8 extends the remarkable 40-year acquisition of space-based land remote-sensing data. To respond quickly to emergency needs, real-time data are directly downlinked to 17 ground stations across the world on a routine basis. With a size of approximately 1 Gb per scene, however, the standard level-1 product provided by these stations is not able to serve the general public. Users would like to browse the most up-to-date and historical images of their regions of interest (ROI at full-resolution from all kinds of devices without the need for tedious data downloading, decompressing, and processing. This paper reports on the Landsat-8 automatic image processing system (L-8 AIPS that incorporates the function of mask developed by United States Geological Survey (USGS, the pan-sharpening technique of spectral summation intensity modulation, the adaptive contrast enhancement technique, as well as the Openlayers and Google Maps/Earth compatible superoverlay technique. Operation of L-8 AIPS enables the most up-to-date Landsat-8 images of Taiwan to be browsed with a clear contrast enhancement regardless of the cloud condition, and in only one hour’s time after receiving the raw data from the USGS Level 1 Product Generation System (LPGS. For any ROI in Taiwan, all historical Landsat-8 images can also be quickly viewed in time series at full resolution (15 m. The debris flow triggered by Typhoon Soudelor (8 August 2015, as well as the barrier lake formed and the large-scale destruction of vegetation after Typhoon Nepartak (7 July 2016, are given as three examples of successful applications to demonstrate that the gap between the user’s needs and the existing Level-1 product from LPGS can be bridged by providing browsable images in near real-time.

  8. Evaluation of cervical lymph node metastasis in thyroid cancer patients using real-time CT navigated ultrasonography: preliminary study

    International Nuclear Information System (INIS)

    Na, Dae Kwon; Choi, Yoon Jung; Choi, Seon Hyeong; Kook, Shin Ho; Park, Hee Jin

    2015-01-01

    To evaluate the diagnostic accuracy of real-time neck computed tomography (CT)-guided ultrasonography (US) in detecting cervical neck lymph node metastasis (LNM) in patients with papillary thyroid cancer (PTC). We retrospectively reviewed data from 176 patients (mean age, 43 years; range, 23 to 74 years) with surgically confirmed PTC who underwent preoperative US, neck CT, and neck CTguided US. We then compared the sensitivities and diagnostic accuracies of each of the three above modalities in detecting cervical LNM. Preoperative US showed 17.3% sensitivity and 58.5% diagnostic accuracy in detecting central LNM compared with 64.3% sensitivity and 89.2% diagnostic accuracy in detecting lateral neck LNM. Neck CT showed 23.5% sensitivity and 55.7% diagnostic accuracy in detecting central LNM and 71.4% sensitivity with 90.9% diagnostic accuracy in detecting lateral neck LNM. CT-guided US exhibited 37.0% sensitivity and 63.1% diagnostic accuracy in detecting central LNM compared with 92.9% sensitivity and 96.0% diagnostic accuracy in detecting lateral LNM. CT-guided US showed higher diagnostic accuracy with superior sensitivity in detecting central and lateral LNM than did US (P<0.001, P=0.011) and CT (P=0.026, P=0.063). Neck CT-guided US is a more accurate technique with higher sensitivity for detecting cervical LNM than either US or CT alone. Therefore, our data indicate that neck CT-guided US is an especially useful technique in preoperative examinations.

  9. Enhancements to NASA's Land Atmosphere Near real-time Capability for EOS (LANCE)

    Science.gov (United States)

    Michael, K.; Davies, D. K.; Schmaltz, J. E.; Boller, R. A.; Mauoka, E.; Ye, G.; Vermote, E.; Harrison, S.; Rinsland, P. L.; Protack, S.; Durbin, P. B.; Justice, C. O.

    2016-12-01

    NASA's Land, Atmosphere Near real-time Capability for EOS (LANCE) supports application users interested in monitoring a wide variety of natural and man-made phenomena. Near Real-Time (NRT) data and imagery from the AIRS, AMSR2, MISR, MLS, MODIS, OMI and VIIRS instruments are available much quicker than routine processing allows. Most data products are available within 3 hours from satellite observation. NRT imagery are generally available 3-5 hours after observation. This article describes LANCE and enhancements made to LANCE over the last year. These enhancements include: the addition of MISR L1 Georeferenced Radiance and L2 Cloud Motion Vector products, AMSR2 Unified L2B Half-Orbit 25 km EASE-Grid Surface Soil Moisture products and VIIRS VIIRS Day/Night Band, Land Surface Reflectance and Corrected Surface reflectance products. In addition, the selection of LANCE NRT imagery that can be interactively viewed through Worldview and the Global Imagery Browse Services (GIBS) has been expanded. LANCE is also working to ingest and process data from OMPS.

  10. Radiofrequency ablation guided by contrast-enhanced ultrasound for hepatic malignancies: Preliminary results

    International Nuclear Information System (INIS)

    Dong, Y.; Wang, W.-P.; Gan, Y.-H.; Huang, B.-J.; Ding, H.

    2014-01-01

    Aim: To evaluate whether contrast-enhanced ultrasound (CEUS)-guided radiofrequency ablation (RFA) can be performed effectively in small hepatic malignancies that are invisible or poorly visualized at traditional grey-scale ultrasonography (US). Materials and methods: The institutional ethics committee approved the study, and all patients provided written informed consent before their enrolment. The study focused on 55 patients (43 men, 12 women, age 57.4 ± 10.9 years) with 60 hepatic lesions from May 2010 to March 2011. All lesions were treated with multipolar radiofrequency ablation (RFA). During the RFA procedure, with the injection of ultrasound contrast agent (sulphur hexafluoride; SonoVue, Bracco Imaging Spa, Milan, Italy), RFA was conducted under CEUS guidance when the optimal depiction of a lesion was obtained. Artificial pleural effusions were used in those cases obstructed by the lungs. Twenty-four hours after RFA, contrast-enhanced MRI was used as the reference standard to evaluate the primary effectiveness rate and complete tumour necrosis. The follow-up time was 12–24 months (median 15 months). Results: Among 60 hepatic malignancies, CEUS detected 57 lesions (95%), which was higher than that at US (26.6%). Artificial pleural effusions were performed in three cases, resulting in the detection of three additional lesions. The insertion of RFA electrodes was monitored by CEUS in all lesions. Immediately after RFA, complete tumour necrosis were achieved in all 60 lesions as apparent at MRI, for a primary effectiveness rate of 100%. Conclusion: CEUS-guided RFA is a promising technique for targeting and improving the efficiency of treatment of hepatic malignancies. - Highlights: • CEUS guided RFA improved the detectability of hepatic malignancies indistinctive on gray-scale ultrasound. • Pre-operation CEUS helped localization of indistinctive hepatic malignancies. • CEUS guided RFA of hepatic malignancies achieved a more complete ablation

  11. Enhancements and Evolution of the Real Time Mission Monitor

    Science.gov (United States)

    Goodman, M.; Blakeslee, R.; Hardin, D.; Hall, J.; He, Y.; Regner, K.

    2008-12-01

    satellite overpass intersections. The resultant flight plan is then generated in KML and quickly posted to the Google Earth-based RTMM for planning discussions, as well as comparisons to real time flight tracks in progress. A description of the system architecture, components, and applications along with reviews and animations of RTMM during the field campaigns, plus planned enhancements and future opportunities will be presented.

  12. Performance enhancement of various real-time image processing techniques via speculative execution

    Science.gov (United States)

    Younis, Mohamed F.; Sinha, Purnendu; Marlowe, Thomas J.; Stoyenko, Alexander D.

    1996-03-01

    In real-time image processing, an application must satisfy a set of timing constraints while ensuring the semantic correctness of the system. Because of the natural structure of digital data, pure data and task parallelism have been used extensively in real-time image processing to accelerate the handling time of image data. These types of parallelism are based on splitting the execution load performed by a single processor across multiple nodes. However, execution of all parallel threads is mandatory for correctness of the algorithm. On the other hand, speculative execution is an optimistic execution of part(s) of the program based on assumptions on program control flow or variable values. Rollback may be required if the assumptions turn out to be invalid. Speculative execution can enhance average, and sometimes worst-case, execution time. In this paper, we target various image processing techniques to investigate applicability of speculative execution. We identify opportunities for safe and profitable speculative execution in image compression, edge detection, morphological filters, and blob recognition.

  13. Supra-aortic low-dose contrast-enhanced time-resolved magnetic resonance (MR) angiography at 3 T: comparison with time-of-flight MR angiography and high-resolution contrast-enhanced MR angiography.

    Science.gov (United States)

    Lee, Youn-Joo; Kim, Bum-soo; Koo, Ja-Sung; Kim, Bom-Yi; Jang, Jinhee; Choi, Hyun Seok; Jung, So-Lyung; Ahn, Kook-Jin

    2015-06-01

    Low-dose, time-resolved, contrast-enhanced, magnetic resonance angiography (TR-CEMRA) has been described previously; however, a comparative study between low dose TR-CEMRA and time-of-flight MRA (TOF-MRA) in the diagnosis of supra-aortic arterial stenosis has not yet been published. To demonstrate the feasibility and effectiveness of low-dose TR-CEMRA compared with TOF-MRA, using high-resolution contrast-enhanced MRA (HR-CEMRA) as the reference standard. This prospective study consisted of 30 consecutive patients. All patients underwent TOF-MRA of the neck and circle of Willis and supra-aortic HR-CEMRA, followed by supra-aortic low-dose TR-CEMRA. Gadoterate meglumine (Gd-DOTA, Dotarem(®), Guerbet, Roissy CdG Cedex, France) was injected at a dose of 0.1 mmol/kg for HR-CEMRA, followed by a 0.03 mmol/kg bolus for low-dose TR-CEMRA. Three readers evaluated the assessibility and image quality, and then two readers classified each stenosis into the following categories: normal (0-30%), mild stenosis (31-50%), moderate (51-70%), severe (71-99%), and occlusion. TR-CEMRA and HR-CEMRA showed a greater number of assessable arterial segments than TOF-MRA (P supra-aortic arterial stenosis, and could be more useful option than TOF-MRA. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. Field strength and dose dependence of contrast enhancement by gadolinium-based MR contrast agents

    International Nuclear Information System (INIS)

    Rinck, P.A.; Muller, R.N.

    1999-01-01

    The relaxivities r 1 and r 2 of magnetic resonance contrast agents and the T 1 relaxation time values of tissues are strongly field dependent. We present quantitative data and simulations of different gadolinium-based extracellular fluid contrast agents and the modulation of their contrast enhancement by the magnetic field to be able to answer the following questions: How are the dose and field dependences of their contrast enhancement? Is there an interrelationship between dose and field dependence? Should one increase or decrease doses at specific fields? Nuclear magnetic relaxation dispersion data were acquired for the following contrast agents: gadopentetate dimeglumine, gadoterate meglumine, gadodiamide injection, and gadoteridol injection, as well as for several normal and pathological human tissue samples. The magnetic field range stretched from 0.0002 to 4.7 T, including the entire clinical imaging range. The data acquired were then fitted with the appropriate theoretical models. The combination of the diamagnetic relaxation rates (R 1 = 1/T 1 and R 2 = 1/T 2 ) of tissues with the respective paramagnetic contributions of the contrast agents allowed the prediction of image contrast at any magnetic field. The results revealed a nearly identical field and dose-dependent increase of contrast enhancement induced by these contrast agents within a certain dose range. The target tissue concentration (TTC) was an important though nonlinear factor for enhancement. The currently recommended dose of 0.1 mmol/kg body weight seems to be a compromise close to the lower limits of diagnostically sufficient contrast enhancement for clinical imaging at all field strengths. At low field contrast enhancement might be insufficient. Adjustment of dose or concentration, or a new class of contrast agents with optimized relaxivity, would be a valuable contribution to a better diagnostic yield of contrast enhancement at all fields. (orig.)

  15. Coordinating Transit Transfers in Real Time

    Science.gov (United States)

    2016-05-06

    Transfers are a major source of travel time variability for transit passengers. Coordinating transfers between transit routes in real time can reduce passenger waiting times and travel time variability, but these benefits need to be contrasted with t...

  16. Interactive dual-volume rendering visualization with real-time fusion and transfer function enhancement

    Science.gov (United States)

    Macready, Hugh; Kim, Jinman; Feng, David; Cai, Weidong

    2006-03-01

    Dual-modality imaging scanners combining functional PET and anatomical CT constitute a challenge in volumetric visualization that can be limited by the high computational demand and expense. This study aims at providing physicians with multi-dimensional visualization tools, in order to navigate and manipulate the data running on a consumer PC. We have maximized the utilization of pixel-shader architecture of the low-cost graphic hardware and the texture-based volume rendering to provide visualization tools with high degree of interactivity. All the software was developed using OpenGL and Silicon Graphics Inc. Volumizer, tested on a Pentium mobile CPU on a PC notebook with 64M graphic memory. We render the individual modalities separately, and performing real-time per-voxel fusion. We designed a novel "alpha-spike" transfer function to interactively identify structure of interest from volume rendering of PET/CT. This works by assigning a non-linear opacity to the voxels, thus, allowing the physician to selectively eliminate or reveal information from the PET/CT volumes. As the PET and CT are rendered independently, manipulations can be applied to individual volumes, for instance, the application of transfer function to CT to reveal the lung boundary while adjusting the fusion ration between the CT and PET to enhance the contrast of a tumour region, with the resultant manipulated data sets fused together in real-time as the adjustments are made. In addition to conventional navigation and manipulation tools, such as scaling, LUT, volume slicing, and others, our strategy permits efficient visualization of PET/CT volume rendering which can potentially aid in interpretation and diagnosis.

  17. Real-time digital angiocardiography using a temporal high-pass filter

    International Nuclear Information System (INIS)

    Hardin, C.W.; Kruger, R.A.; Anderson, F.L.; Bray, B.F.; Nelson, J.A.

    1984-01-01

    A temporal high-pass filtration technique for digital subtraction angiocardiography was studied, using real-time digital studies performed simultaneously with routine cineangiocardiography (cine) for qualitative image comparison. The digital studies showed increased contrast and suppression of background anatomy and also enhanced detection of wall motion abnormalities when compared with cine. The digital images are comparable with, and in some cases better than, cine images. Clinical efficacy of this digital technique is currently being evaluated

  18. Contrast enhancement of cranial lesions in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lewander, R; Bergstroem, M; Bergvall, U [Kungliga Karolinska Mediko-Kirurgiska Inst., Stockholm (Sweden)

    1978-01-01

    The time course of enhancement in apparently normal brain tissue, edema and focal lesions during 30 to 60 min after intravenous injection of vascular contrast medium was evaluated in a series of 41 pateints with differnt intracranial lesions. The attenuation of apparently normal unenhanced brain tissue varied with the level of the scan, mainly an effect of beam hardening. Different types of enhancement response are discussed in terms of a 3-compartment model. The differential diagnostic potential of contrast enhancement in the early phase needs further evaluation using instruments with short scanning time, while the late phase of enhancement must be recorded with the use of a reliable head fixation to provide reproducibility of repeat measurements.

  19. Ultrasonographic contrast-enhanced study of sicca syndrome

    International Nuclear Information System (INIS)

    Giuseppetti, Gian Marco; Argalia, Giulio; Salera, Diego; Ranaldi, Roberto; Danieli, Giovanna; Cappelli, Marida

    2005-01-01

    Objective: To assess the ability of US contrast-enhanced time-intensity curves to depict the changes connected with sicca syndrome, a fairly common condition that is often associated with autoimmune disorders such as Sjogren's syndrome or other diseases. Diagnostic criteria are complex and controversial and although no single test can be considered the gold standard, salivary gland scintigraphy and biopsy are reliable diagnostic methods. Materials and methods: Sixty consecutive patients with sicca syndrome, 40 of whom had primary (n = 23) or secondary (n = 17) Sjogren's syndrome and 20 had non-Sjogren's sicca syndrome, selected according to European Community Study Group diagnostic criteria for Sjogren's syndrome and subjected to contrast-enhanced US imaging of the parotids using a second-generation contrast agent with analysis of time-intensity curves at rest and during salivary stimulation, Tc99m salivary gland scintigraphy and labial gland biopsy. Results: In the 40 Sjogren's patients, US enhancement values were significantly lower (P < 0.0001 and P < 0.00003, respectively) than in the 20 non-Sjogren's patients both at rest and during stimulation. In the 23 subjects with the primary syndrome, values during stimulation were significantly lower than in the 17 subjects with the secondary syndrome (P < 0.0006), whereas at rest differences were not significant. Contrast-enhanced US imaging allowed to discriminate Sjogren's from non-Sjogren's sicca patients with 87.5% sensitivity, 85% specificity and 86.7% accuracy and the primary from the secondary syndrome with 78.2% sensitivity, 70.5% specificity and 75% accuracy. Interestingly, in eight patients with the primary syndrome, i.e. those with the more severe gland involvement, enhancement values were lower during stimulation than at rest. Conclusion: Preliminary results indicate that contrast-enhanced US imaging can provide useful information on sicca characterisation and severity

  20. Ultrasonographic contrast-enhanced study of sicca syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Giuseppetti, Gian Marco [Institute of Radiology, University School of Medicine, Umberto I Hospital, Via Conca 1, Ancona (Italy)]. E-mail: gm.giuseppetti@ao-umbertoprimo.marche.it; Argalia, Giulio [Institute of Radiology, University School of Medicine, Umberto I Hospital, Via Conca 1, Ancona (Italy); Salera, Diego [Institute of Radiology, University School of Medicine, Umberto I Hospital, Via Conca 1, Ancona (Italy); Ranaldi, Roberto [Institute of Pathological Anatomy and Histopathology, University School of Medicine, Umberto I Hospital, Ancona (Italy); Danieli, Giovanna [Institute of Internal Medicine, University School of Medicine, Umberto I Hospital, Ancona (Italy); Cappelli, Marida [Institute of Internal Medicine, University School of Medicine, Umberto I Hospital, Ancona (Italy)

    2005-05-01

    Objective: To assess the ability of US contrast-enhanced time-intensity curves to depict the changes connected with sicca syndrome, a fairly common condition that is often associated with autoimmune disorders such as Sjogren's syndrome or other diseases. Diagnostic criteria are complex and controversial and although no single test can be considered the gold standard, salivary gland scintigraphy and biopsy are reliable diagnostic methods. Materials and methods: Sixty consecutive patients with sicca syndrome, 40 of whom had primary (n = 23) or secondary (n = 17) Sjogren's syndrome and 20 had non-Sjogren's sicca syndrome, selected according to European Community Study Group diagnostic criteria for Sjogren's syndrome and subjected to contrast-enhanced US imaging of the parotids using a second-generation contrast agent with analysis of time-intensity curves at rest and during salivary stimulation, Tc99m salivary gland scintigraphy and labial gland biopsy. Results: In the 40 Sjogren's patients, US enhancement values were significantly lower (P < 0.0001 and P < 0.00003, respectively) than in the 20 non-Sjogren's patients both at rest and during stimulation. In the 23 subjects with the primary syndrome, values during stimulation were significantly lower than in the 17 subjects with the secondary syndrome (P < 0.0006), whereas at rest differences were not significant. Contrast-enhanced US imaging allowed to discriminate Sjogren's from non-Sjogren's sicca patients with 87.5% sensitivity, 85% specificity and 86.7% accuracy and the primary from the secondary syndrome with 78.2% sensitivity, 70.5% specificity and 75% accuracy. Interestingly, in eight patients with the primary syndrome, i.e. those with the more severe gland involvement, enhancement values were lower during stimulation than at rest. Conclusion: Preliminary results indicate that contrast-enhanced US imaging can provide useful information on sicca characterisation and

  1. Contrast-enhanced MR imaging monitoring of acute tumor response to chemotherapy

    International Nuclear Information System (INIS)

    Ranney, D.F.; Cohen, J.M.; Antich, P.P.; Endman, W.A.; Kulkarni, P.; Weinreb, J.C.; Giovanella, B.

    1987-01-01

    Treatment responses of human malignant melanomas were monitored at millimeter resolution in athymic mice by injecting a new polymeric contrast agent, Gd-DTPA-dextran (0.1 mmol Gd/kg, intravenously). Proton MR imaging (0.35 T, spin-echo, repetition time = 0.5 second, echo time = 50 msec) was performed 30 hours after administering diphtheria toxin. Pre-contrast medium images revealed only homogeneous intermediate-intensity tumor masses. Post-contrast medium images of untreated (viable) tumors demonstrated 32% enhancement throughout the entire mass. Post-contrast medium images of toxin-treated tumors revealed marked enhancement (65%) of the histologically viable outer rims, lesser enhancement (38%) of heavily damaged subregions, and no enhancement of dead tumor. These acute, contrast medium-enhanced MR images accurately identified tumor subregions that survived for longer than one week

  2. Abducens nerve enhancement demonstrated by multiplanar reconstruction of contrast-enhanced three-dimensional MRI

    International Nuclear Information System (INIS)

    Hosoya, T.; Adachi, M.; Sugai, Y.; Yamaguchi, K.; Yamaguchi, K.; Kato, T.

    2001-01-01

    We describe contrast enhancement of the cisternal portion of the abducens nerve and discuss its clinical significance. We examined 67 patients with ophthalmoplegia using contrast-enhanced 3-dimensional (3D) MRI with multiplanar reconstruction along the nerves and found 16 patients (ten men, six women), aged 10-73 years (mean 34.4 years), with contrast enhancement of the abducens nerve. Of the 36 patients who had an abducens palsy, 14 (39 %) showed contrast enhancement. In the 16 patients, 23 abducens nerves enhanced; 13 were symptomatic and 10 asymptomatic at the time. The causes were disseminated tumour (1), an inflammatory process (3), trauma (2), ischaemia (2) and autoimmune diseases (8), such as the Miller Fisher syndrome, acute ophthalmoparesis, polyneuropathy and multiple sclerosis. Abducens and/or oculomotor nerve enhancement was the only abnormality on MRI in the patients with traumatic or ischaemic neuropathy or autoimmune diseases. There were 14 patients who recovered fully within 1-6 months after treatment, and resolution of the enhancement correlated well with recovery. (orig.)

  3. Abducens nerve enhancement demonstrated by multiplanar reconstruction of contrast-enhanced three-dimensional MRI

    Energy Technology Data Exchange (ETDEWEB)

    Hosoya, T.; Adachi, M.; Sugai, Y. [Dept. of Radiology, Yamagata University School of Medicine (Japan); Yamaguchi, K.; Yamaguchi, K. [Dept. of Ophthalmology, Yamagata University School of Medicine (Japan); Kato, T. [3. Dept. of Internal Medicine, Yamagata University School of Medicine (Japan)

    2001-04-01

    We describe contrast enhancement of the cisternal portion of the abducens nerve and discuss its clinical significance. We examined 67 patients with ophthalmoplegia using contrast-enhanced 3-dimensional (3D) MRI with multiplanar reconstruction along the nerves and found 16 patients (ten men, six women), aged 10-73 years (mean 34.4 years), with contrast enhancement of the abducens nerve. Of the 36 patients who had an abducens palsy, 14 (39 %) showed contrast enhancement. In the 16 patients, 23 abducens nerves enhanced; 13 were symptomatic and 10 asymptomatic at the time. The causes were disseminated tumour (1), an inflammatory process (3), trauma (2), ischaemia (2) and autoimmune diseases (8), such as the Miller Fisher syndrome, acute ophthalmoparesis, polyneuropathy and multiple sclerosis. Abducens and/or oculomotor nerve enhancement was the only abnormality on MRI in the patients with traumatic or ischaemic neuropathy or autoimmune diseases. There were 14 patients who recovered fully within 1-6 months after treatment, and resolution of the enhancement correlated well with recovery. (orig.)

  4. Real-time phase contrast magnetic resonance imaging for assessment of haemodynamics: from phantom to patients

    Energy Technology Data Exchange (ETDEWEB)

    Traber, Julius; Wurche, Lennart; Dieringer, Matthias A.; Utz, Wolfgang; Knobelsdorff-Brenkenhoff, Florian von; Schulz-Menger, Jeanette [Max-Delbrueck-Centrum and Charite -Medical University Berlin and HELIOS Klinikum Berlin-Buch, Department of Cardiology and Nephrology, Working Group on Cardiovascular Magnetic Resonance Imaging, Experimental and Clinical Research Center, Berlin (Germany); Greiser, Andreas [Siemens AG Healthcare Sector, Erlangen (Germany); Jin, Ning [Siemens Medical Solutions USA, Inc., Columbus, OH (United States)

    2016-04-15

    Assessment of haemodynamics is crucial in many cardiac diseases. Phase contrast MRI (PC-MRI) can accurately access it. Arrhythmia is a major limitation in conventional segmented PC-MRI (SEG). A real-time PC-MRI sequence (RT) could overcome this. We validated RT by comparing to SEG. A prototype RT using shared velocity encoding was tested against SEG at 1.5 T in a flow phantom and consecutively included patients with (n = 55) or without (n = 59) aortic valve disease. In patients with atrial fibrillation (Afib, n = 15), only RT was applied. Phantom: PC images were acquired in front of and behind an interchangeable aortic-stenosis-like inlay. Mean velocity and flow were quantified. Patients: PC images were acquired in the ascending aorta, pulmonary trunk and superior caval vein. Peak velocity, stroke volume and regurgitant fraction were quantified. Phantom: Mean velocities (11 ± 1 to 207 ± 10 cm/s) and flow correlated closely between SEG and RT (r ≥ 0.99, ICC ≥ 0.98, p < 0.0005). Patients without AVD or with aortic regurgitation: Concordance of SEG and RT was excellent regarding peak velocities, stroke volumes (r ≥ 0.91, ICC ≥ 0.94, p < 0.0005) and regurgitant fractions (r = 0.95, ICC = 0.95, p < 0.0005). RT was feasible in all patients with Afib. The real-time sequence is accurate compared to conventional segmented PC-MRI. Its applicability in Afib was shown. Real-time PC-MRI might become a valuable tool in arrhythmia. (orig.)

  5. Contrast Enhanced US in the Abdomen

    International Nuclear Information System (INIS)

    Chung, Yong Eun; Kim, Ki Whang

    2012-01-01

    Contrast enhanced ultrasound, which was introduced in 1996, has been widely used in Europe and Eastern Asia. Ultrasound contrast agent can be classified as first generation and second generation, depending on the gas within the microbubble. With the first generation contrast agent, the high MI technique was used, and only intermittent scanning was possible due to destruction of the microbubble during scanning. Use of the second generation contrast agent with the low MI technique makes continuous scanning possible. Contrast enhanced US can be used in detection and differentiation of focal liver lesions. It is also helpful for monitoring of radiofrequency ablation and for targeting of US guided biopsy. Currently, because morphologic criteria alone may not reflect the response of the tumor to treatment, new criteria are needed for treatment evaluation after administration of anti-angiogenic agents. Contrast enhanced US could provide quantitative markers for evaluation of the response to treatment via use of dynamic contrast enhanced US. Due to cost-effectiveness, contrast enhanced US is not yet widely used in Korea; however, considering recent issues regarding contrast agent related adverse reaction, such as contrast induced nephropathy and nephrogenic systemic fibrosis, and radiation exposure, contrast enhanced US might be more widely used in Korea, as an alternative imaging modality in the future.

  6. FDG-PET/contrast-enhanced CT as a post-treatment tool in head and neck squamous cell carcinoma: comparison with FDG-PET/non-contrast-enhanced CT and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Yuko; Kitajima, Kazuhiro; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Ishihara, Takeaki; Sasaki, Ryohei [Kobe University Graduate, School of Medicine, Department of Radiology, Division of Radiation Oncology, Kobe (Japan); Otsuki, Naoki; Nibu, Ken-ichi [Kobe University Graduate, School of Medicine, Department of Otolaryngology-Head and Neck Surgery, Kobe (Japan); Minamikawa, Tsutomu [Kobe University Graduate School of Medicine, Department of Oral and Maxillofacial Surgery, Kobe (Japan); Kiyota, Naomi [Kobe University Hospital, Department of Medical Oncology and Hematology, Kobe (Japan)

    2016-04-15

    To evaluate the accuracy of PET/CT using {sup 18}F-fluorodeoxyglucose (FDG) with IV contrast for suspected recurrent head and neck squamous cell carcinoma (HNSCC). One hundred and seventy patients previously treated for HNSCC underwent PET/CT, consisting of non-contrast-enhanced and contrast-enhanced CT, to investigate suspected recurrence. Diagnostic performance of PET/contrast-enhanced CT (PET/ceCT), PET/non-contrast-enhanced CT (PET/ncCT) and contrast-enhanced CT (ceCT) for local or regional recurrence, distant metastasis, overall recurrence and second primary cancer was evaluated. The reference standard included histopathology, treatment change and imaging follow-up. The patient-based areas under the receiver operating characteristic curves (AUC) for ceCT, PET/ncCT and PET/ceCT were 0.82, 0.96 and 0.98 for local recurrence, 0.73, 0.86 and 0.86 for regional recurrence, 0.86, 0.91 and 0.92 for distant metastasis, 0.72, 0.86 and 0.87 for overall recurrence, and 0.86, 0.89 and 0.91 for a second primary cancer. Both PET/ceCT and PET/ncCT statistically showed larger AUC than ceCT for recurrence, and the difference between PET/ceCT and PET/ncCT for local recurrence reached a significant level (p = 0.039). The accuracy of PET/ceCT for diagnosing overall recurrence was high, irrespective of the time interval after the last treatment (83.3-94.1 %). FDG-PET/CT was a more accurate HNSCC restaging tool than ceCT. The added value of ceCT at FDG-PET/CT is minimal. (orig.)

  7. Visualization of swallowing using real-time TrueFISP MR fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Barkhausen, Joerg; Goyen, Mathias; Lauenstein, Thomas; Debatin, Joerg F. [Department of Diagnostic Radiology, University Hospital Essen (Germany); Winterfeld, F. von; Arweiler-Harbeck, Diana [Department of Otorhinolaryngology, University Hospital Essen (Germany)

    2002-01-01

    The aim of this study was to evaluate the ability of different real-time true fast imaging with steady precession (TrueFISP) sequences regarding their ability to depict the swallowing process and delineate oropharyngeal pathologies in patients with dysphagia. Real-time TrueFISP visualization of swallowing was performed in 8 volunteers and 6 patients with dysphagia using a 1.5 T scanner (Magnetom Sonata, Siemens, Erlangen Germany) equipped with high-performance gradients (amplitude 40 mT/m). Image quality of four different real-time TrueFISP sequences (TR 2.2-3.0 ms, TE 1.1-1.5 ms, matrix 63 x 128-135 x 256, field of view 250 mm{sup 2}, acquisition time per image 139-405 ms) was evaluated. Water, yoghurt, and semolina pudding were assessed as oral contrast agents. Functional exploration of the oropharyngeal apparatus was best possible using the fastest real-time TrueFISP sequence (TR 2.2 ms, TE 1.1 ms, matrix 63 x 128). Increased acquisition time resulted in blurring of anatomical structures. As the image contrast of TrueFISP sequences depends on T2/T1 properties, all tested foodstuff were well suited as oral contrast agents, but image quality was best using semolina pudding. Real-time visualization of swallowing is possible using real-time TrueFISP sequences in conjunction with oral contrast agents. For the functional exploration of swallowing high temporal resolution is more crucial than spatial resolution. (orig.)

  8. Newly Diagnosed Breast Cancer: Comparison of Contrast-enhanced Spectral Mammography and Breast MR Imaging in the Evaluation of Extent of Disease.

    Science.gov (United States)

    Lee-Felker, Stephanie A; Tekchandani, Leena; Thomas, Mariam; Gupta, Esha; Andrews-Tang, Denise; Roth, Antoinette; Sayre, James; Rahbar, Guita

    2017-11-01

    Purpose To compare the diagnostic performances of contrast material-enhanced spectral mammography and breast magnetic resonance (MR) imaging in the detection of index and secondary cancers in women with newly diagnosed breast cancer by using histologic or imaging follow-up as the standard of reference. Materials and Methods This institutional review board-approved, HIPAA-compliant, retrospective study included 52 women who underwent breast MR imaging and contrast-enhanced spectral mammography for newly diagnosed unilateral breast cancer between March 2014 and October 2015. Of those 52 patients, 46 were referred for contrast-enhanced spectral mammography and targeted ultrasonography because they had additional suspicious lesions at MR imaging. In six of the 52 patients, breast cancer had been diagnosed at an outside institution. These patients were referred for contrast-enhanced spectral mammography and targeted US as part of diagnostic imaging. Images from contrast-enhanced spectral mammography were analyzed by two fellowship-trained breast imagers with 2.5 years of experience with contrast-enhanced spectral mammography. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value were calculated for both imaging modalities and compared by using the Bennett statistic. Results Fifty-two women with 120 breast lesions were included for analysis (mean age, 50 years; range, 29-73 years). Contrast-enhanced spectral mammography had similar sensitivity to MR imaging (94% [66 of 70 lesions] vs 99% [69 of 70 lesions]), a significantly higher PPV than MR imaging (93% [66 of 71 lesions] vs 60% [69 of 115 lesions]), and fewer false-positive findings than MR imaging (five vs 45) (P contrast-enhanced spectral mammography depicted 11 of the 11 secondary cancers (100%) and MR imaging depicted 10 (91%). Conclusion Contrast-enhanced spectral mammography is potentially as sensitive as MR imaging in the evaluation of extent of disease in newly diagnosed

  9. Intravenous digital subtraction angiography contrast media time-concentration curves

    International Nuclear Information System (INIS)

    Burbank, F.H.; Brody, W.R.

    1985-01-01

    At any specified radiation dose and system signal-to-noise ratio, temporal (masked-mode) intravenous digital subtraction angiography (IV-DSA) image quality is dependent upon the shape of the arterial time-concentration curve produced by the intravenous injection of iodinated contrast media. If contrast media appears in the arterial circulation as a compact bolus and reaches a high peak, images containing low or no iodine (the mask image or images) and high iodine concentration (the enhanced image or images) can be obtained close together in time, maximizing contrast media enhancement and minimizing the potential for spatial movement (misregistration). However, if the contrast media bolus is broad, rising slowly to a low concentration peak, sufficient time may pass for movement to occur and the opacification difference between the mask image and the enhanced image may be too small to visualize vessels of interest. Consequently, knowledge of the rules which govern the formation of time-concentration curves is central to IV-DSA

  10. Contrast enhanced ultrasound of splenic lymphoma involvement

    International Nuclear Information System (INIS)

    Goerg, Christian; Faoro, Charis; Bert, Tillmann; Tebbe, Johannes; Neesse, Albrecht; Wilhelm, Christian

    2011-01-01

    Objective: The aim of this study was to compare the value of contrast-enhanced ultrasonography (CEUS) with standard B-mode ultrasound (US) for diagnosis of splenic lymphoma involvement. Methods: From 04/2005 to 10/2008 n = 250 lymphoma patients were investigated by standard B-mode US. A homogeneous splenic echotexture was found in 199 patients (79%). To clarify the benefit of CEUS in this group a pilot series was performed with 16 of the 199 lymphoma patients. All patients with an abnormal splenic echotexture on standard B-Mode US (n = 51) including focal hypoechoic splenic lesions (n = 41) and an inhomogeneous splenic texture (n = 10) were studied by CEUS. CEUS data were retrospectively evaluated. The diagnoses included indolent lymphoma (n = 27), aggressive lymphoma (n = 14), and Hodgkin's disease (n = 10). Number and size of lesions were determined by B-mode US and CEUS. The visualisation of splenic lymphoma involvement by CEUS in comparison to B-mode US was classified as worse, equal, or better. Results: All patients with a homogeneous spleen on B-mode US (n = 16) had no visible focal lesions on CEUS. Study patients with focal lesions (n = 41) had a hypoechoic (n = 22) or isoechoic (n = 19) enhancement during the arterial phase, and a hypoechoic enhancement during the parenchymal phase (n = 41). The visualisation of focal splenic lymphoma was equal (n = 32), better (n = 6), or worse (n = 3). In all study patients with an inhomogeneous spleen on B-mode US (n = 10) no focal lesions were found by CEUS and the value of CEUS therefore was classified as worse. Conclusion: CEUS has no clear advantage for diagnosis of splenic lymphoma involvement.

  11. Contrast enhanced ultrasound of splenic lymphoma involvement

    Energy Technology Data Exchange (ETDEWEB)

    Goerg, Christian, E-mail: goergc@med.uni-marburg.de [Medizinische Universitaetsklinik, Baldingerstrasse, 35033 Marburg/Lahn (Germany); Faoro, Charis [Medizinische Universitaetsklinik, Baldingerstrasse, 35033 Marburg/Lahn (Germany); Bert, Tillmann [Zentralklinik Bad Berka GmbH, Robert-Koch-Allee 9, 99437 Bad Berka (Germany); Tebbe, Johannes [Klinikum Lippe-Detmold, Roentgenstrasse 18, 32756 Detmold (Germany); Neesse, Albrecht; Wilhelm, Christian [Medizinische Universitaetsklinik, Baldingerstrasse, 35033 Marburg/Lahn (Germany)

    2011-11-15

    Objective: The aim of this study was to compare the value of contrast-enhanced ultrasonography (CEUS) with standard B-mode ultrasound (US) for diagnosis of splenic lymphoma involvement. Methods: From 04/2005 to 10/2008 n = 250 lymphoma patients were investigated by standard B-mode US. A homogeneous splenic echotexture was found in 199 patients (79%). To clarify the benefit of CEUS in this group a pilot series was performed with 16 of the 199 lymphoma patients. All patients with an abnormal splenic echotexture on standard B-Mode US (n = 51) including focal hypoechoic splenic lesions (n = 41) and an inhomogeneous splenic texture (n = 10) were studied by CEUS. CEUS data were retrospectively evaluated. The diagnoses included indolent lymphoma (n = 27), aggressive lymphoma (n = 14), and Hodgkin's disease (n = 10). Number and size of lesions were determined by B-mode US and CEUS. The visualisation of splenic lymphoma involvement by CEUS in comparison to B-mode US was classified as worse, equal, or better. Results: All patients with a homogeneous spleen on B-mode US (n = 16) had no visible focal lesions on CEUS. Study patients with focal lesions (n = 41) had a hypoechoic (n = 22) or isoechoic (n = 19) enhancement during the arterial phase, and a hypoechoic enhancement during the parenchymal phase (n = 41). The visualisation of focal splenic lymphoma was equal (n = 32), better (n = 6), or worse (n = 3). In all study patients with an inhomogeneous spleen on B-mode US (n = 10) no focal lesions were found by CEUS and the value of CEUS therefore was classified as worse. Conclusion: CEUS has no clear advantage for diagnosis of splenic lymphoma involvement.

  12. Ultrasonographic detection of focal liver lesions: increased sensitivity and specificity with microbubble contrast agents

    International Nuclear Information System (INIS)

    Hohmann, J.; Albrecht, T.; Hoffmann, C.W.; Wolf, K.-J.

    2003-01-01

    Ultrasonography (US) is the first choice for screening patients with suspected liver lesions. However, due to a lack of contrast agents, US used to be less sensitive and specific compared with computed tomography (CT) and magnet resonance imaging (MRI). The advent of microbubble contrast agents increased both sensitivity and specificity dramatically. Rapid developments of the contrast agents as well as of special imaging techniques were made in recent years. Today numerous different US imaging methods exist which based either on Doppler or on harmonic imaging. They are using the particular behaviour of microbubbles in a sound field which varies depending on the energy of insonation (low/high mechanical index, MI) as well as on the properties of the agent themselves. Apart from just blood pool enhancement some agents have a hepatosplenic specific late phase. US imaging during this late phase using relatively high MI in phase inversion mode (harmonic imaging) or stimulated acoustic emission (SAE; Doppler method) markedly improves the detection of focal liver lesions and is also very helpful for lesion characterisation. With regards to detection, contrast enhanced US performs similarly to CT as shown by recent studies. Early results of studies using low MI imaging and the newer perfluor agents are also showing promising results for lesion detection. Low MI imaging with these agents has the advantage of real time imaging and is particularly helpful for characterisation of focal lesions based on their dynamic contrast behaviour. Apart from the techniques which based on the morphology of liver lesions there were some attempts for the detection of occult metastases or micrometastases by means of liver blood flow changes. Also in this field the use of US contrast agents appears to have advantages over formerly used non contrast-enhanced methods although no conclusive results are available yet

  13. Enhancing the accuracy of subcutaneous glucose sensors: a real-time deconvolution-based approach.

    Science.gov (United States)

    Guerra, Stefania; Facchinetti, Andrea; Sparacino, Giovanni; Nicolao, Giuseppe De; Cobelli, Claudio

    2012-06-01

    Minimally invasive continuous glucose monitoring (CGM) sensors can greatly help diabetes management. Most of these sensors consist of a needle electrode, placed in the subcutaneous tissue, which measures an electrical current exploiting the glucose-oxidase principle. This current is then transformed to glucose levels after calibrating the sensor on the basis of one, or more, self-monitoring blood glucose (SMBG) samples. In this study, we design and test a real-time signal-enhancement module that, cascaded to the CGM device, improves the quality of its output by a proper postprocessing of the CGM signal. In fact, CGM sensors measure glucose in the interstitium rather than in the blood compartment. We show that this distortion can be compensated by means of a regularized deconvolution procedure relying on a linear regression model that can be updated whenever a pair of suitably sampled SMBG references is collected. Tests performed both on simulated and real data demonstrate a significant accuracy improvement of the CGM signal. Simulation studies also demonstrate the robustness of the method against departures from nominal conditions, such as temporal misplacement of the SMBG samples and uncertainty in the blood-to-interstitium glucose kinetic model. Thanks to its online capabilities, the proposed signal-enhancement algorithm can be used to improve the performance of CGM-based real-time systems such as the hypo/hyper glycemic alert generators or the artificial pancreas.

  14. The usefulness of contrast-enhanced sonography in the differential diagnostic of adrenal tumors

    International Nuclear Information System (INIS)

    Slonina, J.; Nienartowicz, E.; Malczewska, J.; Moron, K.; Kumar Agrawal, A.

    2006-01-01

    Introduction: The occurrence of gland tumors causes significant clinical problem. Non hormone-secreting tumors provide the most complicated diagnostic difficulties. The application of contrast-enhanced sonography could improve the vessels visualization and point out characteristic features of benign and malignant changes. The authors believe that this new method make possible the differential adrenal tumor diagnostic process more precise and increase the specificity of ultrasonography in the recognition of benign and malignant tumors. The aim of this study was to define the usefulness of contrasting agent Levovist in differential diagnostics of adrenal tumors and its influence on sensitivity and specificity of ultrasound examination and to establish patients qualification criteria for surgical procedures. Material and methods: Ultrasound examinations were made with the use of digital devise by GE Voluson 740, probe 4.6 MHz with Doppler options and volumetric probe 3D according to the following protocol: 26 patients with recognized adrenal tumor were qualified for the examination. Patients in the first stage of tumor vascularisation had Doppler examination with color (CD) and power Doppler (PD). Three-dimensional ultrasonography was used to improve visualization of vascularisation. In the final phase of the examination the patients were administrated of Levovist in the recommended by the producer dose: 2,5 g in the concentration of 400 mg/l. Results: 26 cases of adrenal gland tumours were subjected to analysis. In standard ultrasonographic examination focal changes in 25 patients were hipoechogenic focuses and in one case the focus was hyperechogenic. Heterogeneity of focuses was observed in 16 cases. In Doppler examination with color (CD) and power Doppler (PD) vascular blood flow was revealed within 12. After using contrasting agent Levovist vascular blood flow was achieved in 4 additional cases, which constituted 61% . Conclusions: 1. 3D ultrasound could be

  15. Contrast-enhanced peripheral MRA. Technique and contrast agents

    International Nuclear Information System (INIS)

    Nielsen, Yousef W.; Thomsen, Henrik S.

    2012-01-01

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X

  16. Enhanced Interrupt Response Time in the nMPRA based on Embedded Real Time Microcontrollers

    Directory of Open Access Journals (Sweden)

    GAITAN, N. C.

    2017-08-01

    Full Text Available In any real-time operating system, task switching and scheduling, interrupts, synchronization and communication between processes, represent major problems. The implementation of these mechanisms through software generates significant delays for many applications. The nMPRA (Multi Pipeline Register Architecture architecture is designed for the implementation of real-time embedded microcontrollers. It supports the competitive execution of n tasks, enabling very fast switching between them, with a usual delay of one machine cycle and a maximum of 3 machine cycles, for the memory-related work instructions. This is because each task has its own PC (Program Counter, set of pipeline registers and a general registers file. The nMPRA is provided with an advanced distributed interrupt controller that implements the concept of "interrupts as threads". This allows the attachment of one or more interrupts to the same task. In this context, the original contribution of this article is to presents the solutions for improving the response time to interrupts when a task has attached a large number of interrupts. The proposed solutions enhance the original architecture for interrupts logic in order to transfer control, to the interrupt handler as soon as possible, and to create an interrupt prioritization at task level.

  17. Analysis of factors influencing the integrated bolus peak timing in contrast-enhanced brain computed tomographic angiography

    International Nuclear Information System (INIS)

    Son, Soon Yong; Choi, Kwan Woo; Jeong, Hoi Woun; Jang, Seo Goo; Jung, Jae Young; Yun, Jung Soo; Kim, Ki Won; Lee, Young Ah; Son, Jin Hyun; Min, Jung Whan

    2016-01-01

    The objective of this study was to analyze the factors influencing integrated bolus peak timing in contrast- enhanced computed tomographic angiography (CTA) and to determine a method of calculating personal peak time. The optimal time was calculated by performing multiple linear regression analysis, after finding the influence factors through correlation analysis between integrated peak time of contrast medium and personal measured value by monitoring CTA scans. The radiation exposure dose in CTA was 716.53 mGy·cm and the radiation exposure dose in monitoring scan was 15.52 mGy (2 - 34 mGy). The results were statistically significant (p < .01). Regression analysis revealed, a -0.160 times decrease with a one-step increase in heart rate in male, and -0.004, -0.174, and 0.006 times decrease with one-step in DBP, heart rate, and blood sugar, respectively, in female. In a consistency test of peak time by calculating measured peak time and peak time by using the regression equation, the consistency was determined to be very high for male and female. This study could prevent unnecessary dose exposure by encouraging in clinic calculation of personal integrated peak time of contrast medium prior to examination

  18. Characterisation of focal liver lesions with unenhanced and contrast enhanced low MI real time ultrasound: On-site unblinded versus off-site blinded reading

    International Nuclear Information System (INIS)

    Hohmann, Joachim; Skrok, Jan; Basilico, Raffaella; Jennett, Manfred; Müller, Anja; Wolf, Karl-Jürgen; Albrecht, Thomas

    2012-01-01

    Objective: To compare on-site and blinded off-site reading of baseline ultrasound (US) and contrast enhanced ultrasound (CEUS) for classification and characterisation of focal liver lesions. Materials and methods: 99 patients (57 women and 42 men, age range 18–89 years, mean age: 59 years) with 53 malignant and 46 benign liver lesions were studied with unenhanced US followed by contrast enhanced US after injection of 2.4 ml SonoVue ® (Bracco, Milano, Italy). Image interpretation was performed on-site with clinical information available by consensus of two readers and off-site by two independent blinded readers at two different centers. Comparison of pre and post contrast scans and of the different readers was performed. Reference examinations were histology, intraoperative US, MRI or CT. Results: Sensitivity for malignancy improved from 81/89/66% (on-site/off-site reader 1/2) before to 100/96/96% post contrast administration (p < 0.05, except for reader 1). Specificity improved from 48/48/54% on baseline US to 89/80/76% on CEUS (p < 0.05). Accuracy for specific lesion diagnosis was 62/59/50% pre and 90/77/72% post contrast (p < 0.05). Classification and characterisation post contrast were mildly inferior for off-site reading. Agreement between on-site and off-site readers of unenhanced scans was fair (κ = 0.29–0.39) while it was good for CEUS (κ = 0.63–0.79). Conclusions: CEUS improves classification and characterisation of focal liver lesions and interobserver agreement compared to conventional US. Classification and characterisation post contrast were mildly but statistically significantly better for on-site than for off-site reading.

  19. Contrast-enhanced thoracic 3D-MR angiography in infants and children

    International Nuclear Information System (INIS)

    Holmqvist, C.; Larsson, E.M.; Staahlberg, F.; Laurin, S.

    2000-01-01

    To optimise breath-hold contrast-enhanced MR angiography (MRA) in infants and children with suspected congenital heart or thoracic vessel malformation. Thirty-nine children (median age 1 year) were examined, using five different ultrafast MRA sequences with a TR between 3.2 and 5.0 ms and the contrast agent meglumine gadoterate. A test injection was used to determine contrast travel time. Different parameters for contrast injection were evaluated. Signal-to-noise ratio (SNR) measurements were performed and image quality and injection timing were evaluated. MRA was successful in all patients and image quality was considered very good in 52%. Adequate SNR was achieved with no significant differences between the MR sequences. SNR decreased only 25 - 30% between subsequent scans. The mean contrast dose was 0.23 mmol/kg. The mean scan time was 12.5±3.8 s; the shorter scan times made dynamic examinations possible with high temporal resolution. Highest spatial resolution was obtained with TR 4.6/5.0 sequences. A contrast dose of 0.2 mmol/kg b.w. is recommended with an injection rate of 0.5 to 1.2 ml/s, depending on patient size and scan time. The scan delay time should equal the contrast travel time for optimal vessel enhancement. In the future, contrast-enhanced MRA may be a potential alternative to angiocardiography in infants and children

  20. Clinical value of elasticity imaging and contrast-enhanced ultrasound in the diagnosis of papillary thyroid microcarcinoma.

    Science.gov (United States)

    Li, Fengsheng; Zhang, Jianlei; Wang, Yunmei; Liu, Liwen

    2015-09-01

    The present study aimed to evaluate the value of elasticity imaging and contrast-enhanced ultrasonography (CEUS) in the differential diagnosis of papillary thyroid microcarcinoma (TMC). In total, 73 patients exhibiting a total of 80 small thyroid nodules, which were difficult to diagnose using conventional ultrasonography, underwent elasticity imaging and CEUS. The diagnostic findings were subsequently clarified by intraoperative and pathological examination, and the accuracy of the 2 diagnostic methods was compared. The correct diagnostic rate of CEUS was 85% (68/80 nodules), of which 6 cases of TMC were misdiagnosed as benign lesions and 6 benign nodules were misdiagnosed as TMC. By contrast, the accuracy rate of the elasticity imaging, based on the 5-point diagnostic method, was 92.5% (74/80 nodules), of which 3 cases of TMC were misdiagnosed as benign nodules and 3 benign nodules were misdiagnosed as TMC. Furthermore, elasticity imaging in the diagnosis of TMC was determined to have sensitivity, specificity and accuracy rates of 94.0, 90.0 and 92.5%, respectively, whereas the corresponding rates for CEUS were 88.0, 80.0 and 85.0%, respectively. Thus, ultrasonographic elasticity imaging exhibited significant advantages in the diagnosis of TMC compared with CEUS (Padvantage in the diagnosis of TMC; however, an elasticity score of ≥3 is of high clinical value as a diagnostic criterion for TMC.

  1. Contrast-enhanced ultrasound evaluation of hepatic microvascular changes in liver diseases.

    Science.gov (United States)

    Ridolfi, Francesco; Abbattista, Teresa; Busilacchi, Paolo; Brunelli, Eugenio

    2012-10-07

    To assess if software assisted-contrast-enhanced ultrasonography (CEUS) provides reproducible perfusion parameters of hepatic parenchyma in patients affected by chronic liver disease. Forty patients with chronic viral liver disease, with (n = 20) or without (n = 20) cirrhosis, and 10 healthy subjects underwent CEUS and video recordings of each examination were then analysed with Esaote's Qontrast software. CEUS dedicated software Qontrast was used to determine peak (the maximum signal intensity), time to peak (TTP), region of blood value (RBV) proportional to the area under the time-intensity curve, mean transit time (MTT) measured in seconds and region of blood flow (RBF). Qontrast-assisted CEUS parameters displayed high inter-observer reproducibility (κ coefficients of 0.87 for MTT and 0.90 TTP). When the region of interest included a main hepatic vein, Qontrast-calculated TTP was significantly shorter in cirrhotic patients (vs non-cirrhotics and healthy subjects) (71.0 ± 11.3 s vs. 82.4 ± 15.6 s, 86.3 ± 20.3 s, P < 0.05). MTTs in the patients with liver cirrhosis were significantly shorter than those of controls (111.9 ± 22.0 s vs. 139.4 ± 39.8 s, P < 0.05), but there was no significant difference between the cirrhotic and non-cirrhotic groups (111.9 ± 22.0 s vs. 110.3 ± 14.6 s). Peak enhancement in the patients with liver cirrhosis was also higher than that observed in controls (23.9 ± 5.9 vs. 18.9 ± 7.1, P = 0.05). There were no significant intergroup differences in the RBVs and RBFs. Qontrast-assisted CEUS revealed reproducible differences in liver perfusion parameters during the development of hepatic fibrogenesis.

  2. New real-time image processing system for IRFPA

    Institute of Scientific and Technical Information of China (English)

    WANG Bing-jian; LIU Shang-qian; CHENG Yu-bao

    2006-01-01

    Influenced by detectors' material,manufacturing technology etc,every detector in infrared focal plane array (IRFPA) will output different voltages even if their input radiation flux is the same.And this is called non-uniformity of IRFPA.At the same time,the high background temperature,low temperature difference between targets and background and the low responsivity of IRFPA result in low contrast of infrared images.So non-uniformity correction and image enhancement are important techniques for IRFPA imaging system.This paper proposes a new real-time infrared image processing system based on Field Programmable Gate Array(FPGA).The system implements non-uniformity correction,image enhancement and video synthesization etc.By using parallel architecture and pipeline technique,the system processing speed is as high as 50Mx12bits per second.It is appropriate greatly to a large IRFPA and a high frame frequency IRFPA imaging system.The system is miniatured in one FPGA.

  3. Clinical impact of EUS elastography followed by contrast-enhanced EUS in patients with focal pancreatic masses and negative EUS-guided FNA

    DEFF Research Database (Denmark)

    Iordache, Sevastiţa; Costache, Mădălin Ionuţ; Popescu, Carmen Florina

    2016-01-01

    and negative cytopathology after EUS-FNA, based on previously published results and cut-offs of real-time elastographic (RTE) EUS and contrast-enhanced harmonic (CEH) EUS. MATERIAL AND METHODS: We included in the study a subgroup of 50 consecutive patients with focal pancreatic masses which underwent EUS...... malignancy, the sensitivity, specificity and accuracy of RTE-EUS were: 97.7%, 77.4%, and 84% respectively. CEH-EUS had similar results: 89.5%, 80.7%, and 84%, respectively. In 25 patients with soft/mixed appearance during elastography,sequential assessment using contrast-enhanced EUSwas performed...

  4. Ultrasonography for Proper Endotracheal Tube Placement Confirmation in Out-of-hospital Cardiac Arrest Patients: Two-center Experience

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Conclusion: Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during cardiopulmonary resuscitation without the need for interruption of chest compression.

  5. Vascular Structure Identification in Intraoperative 3D Contrast-Enhanced Ultrasound Data

    Directory of Open Access Journals (Sweden)

    Elisee Ilunga-Mbuyamba

    2016-04-01

    Full Text Available In this paper, a method of vascular structure identification in intraoperative 3D Contrast-Enhanced Ultrasound (CEUS data is presented. Ultrasound imaging is commonly used in brain tumor surgery to investigate in real time the current status of cerebral structures. The use of an ultrasound contrast agent enables to highlight tumor tissue, but also surrounding blood vessels. However, these structures can be used as landmarks to estimate and correct the brain shift. This work proposes an alternative method for extracting small vascular segments close to the tumor as landmark. The patient image dataset involved in brain tumor operations includes preoperative contrast T1MR (cT1MR data and 3D intraoperative contrast enhanced ultrasound data acquired before (3D-iCEUS s t a r t and after (3D-iCEUS e n d tumor resection. Based on rigid registration techniques, a preselected vascular segment in cT1MR is searched in 3D-iCEUS s t a r t and 3D-iCEUS e n d data. The method was validated by using three similarity measures (Normalized Gradient Field, Normalized Mutual Information and Normalized Cross Correlation. Tests were performed on data obtained from ten patients overcoming a brain tumor operation and it succeeded in nine cases. Despite the small size of the vascular structures, the artifacts in the ultrasound images and the brain tissue deformations, blood vessels were successfully identified.

  6. Value of adenosine infusion for infarct size determination using real-time myocardial contrast echocardiography

    Directory of Open Access Journals (Sweden)

    da Luz Protásio

    2006-02-01

    Full Text Available Abstract Background Myocardial contrast echocardiography has been used for determination of infarct size (IS in experimental models. However, with intermittent harmonic imaging, IS seems to be underestimated immediately after reperfusion due to areas with preserved, yet dysfunctional, microvasculature. The use of exogenous vasodilators showed to be useful to unmask these infarcted areas with depressed coronary flow reserve. This study was undertaken to assess the value of adenosine for IS determination in an open-chest canine model of coronary occlusion and reperfusion, using real-time myocardial contrast echocardiography (RTMCE. Methods Nine dogs underwent 180 minutes of coronary occlusion followed by reperfusion. PESDA (Perfluorocarbon-Exposed Sonicated Dextrose Albumin was used as contrast agent. IS was determined by RTMCE before and during adenosine infusion at a rate of 140 mcg·Kg-1·min-1. Post-mortem necrotic area was determined by triphenyl-tetrazolium chloride (TTC staining. Results IS determined by RTMCE was 1.98 ± 1.30 cm2 and increased to 2.58 ± 1.53 cm2 during adenosine infusion (p = 0.004, with good correlation between measurements (r = 0.91; p 2 and showed no significant difference with IS determined by RTMCE before or during hyperemia. A slight better correlation between RTMCE and TTC measurements was observed during adenosine (r = 0.99; p Conclusion RTMCE can accurately determine IS in immediate period after acute myocardial infarction. Adenosine infusion results in a slight better detection of actual size of myocardial damage.

  7. Dynamic contrast-enhanced MR imaging of endometrial cancer. Optimizing the imaging delay for tumour-myometrium contrast

    International Nuclear Information System (INIS)

    Park, Sung Bin; Moon, Min Hoan; Sung, Chang Kyu; Oh, Sohee; Lee, Young Ho

    2014-01-01

    To investigate the optimal imaging delay time of dynamic contrast-enhanced magnetic resonance (MR) imaging in women with endometrial cancer. This prospective single-institution study was approved by the institutional review board, and informed consent was obtained from the participants. Thirty-five women (mean age, 54 years; age range, 29-66 years) underwent dynamic contrast-enhanced MR imaging with a temporal resolution of 25-40 seconds. The signal intensity difference ratios between the myometrium and endometrial cancer were analyzed to investigate the optimal imaging delay time using single change-point analysis. The optimal imaging delay time for appropriate tumour-myometrium contrast ranged from 31.7 to 268.1 seconds. The median optimal imaging delay time was 91.3 seconds, with an interquartile range of 46.2 to 119.5 seconds. The median signal intensity difference ratios between the myometrium and endometrial cancer were 0.03, with an interquartile range of -0.01 to 0.06, on the pre-contrast MR imaging and 0.20, with an interquartile range of 0.15 to 0.25, on the post-contrast MR imaging. An imaging delay of approximately 90 seconds after initiating contrast material injection may be optimal for obtaining appropriate tumour-myometrium contrast in women with endometrial cancer. (orig.)

  8. Multiprocessor scheduling for real-time systems

    CERN Document Server

    Baruah, Sanjoy; Buttazzo, Giorgio

    2015-01-01

    This book provides a comprehensive overview of both theoretical and pragmatic aspects of resource-allocation and scheduling in multiprocessor and multicore hard-real-time systems.  The authors derive new, abstract models of real-time tasks that capture accurately the salient features of real application systems that are to be implemented on multiprocessor platforms, and identify rules for mapping application systems onto the most appropriate models.  New run-time multiprocessor scheduling algorithms are presented, which are demonstrably better than those currently used, both in terms of run-time efficiency and tractability of off-line analysis.  Readers will benefit from a new design and analysis framework for multiprocessor real-time systems, which will translate into a significantly enhanced ability to provide formally verified, safety-critical real-time systems at a significantly lower cost.

  9. Non-contrast-enhanced 3D volumetric time-resolved MRA combining PCASL for intracranial vessels. President award proceedings

    International Nuclear Information System (INIS)

    Nakamura, Masanobu; Yoneyama, Masami; Tabuchi, Takashi; Tatsuno, Satoshi; Takemura, Atsushi; Obara, Makoto; Takahara, Taro

    2013-01-01

    Hemodynamic information is required for accurate diagnosis, effective treatment, and follow-up examination of numerous cerebrovascular diseases. A recently introduced technique for non-contrast 3-dimensional (3D) volumetric time-resolved magnetic resonance angiography (MRA)-contrast inherent inflow enhanced multi phase angiography (CINEMA)-provides useful qualitative information on the morphologic and dynamic filling of intracranial vessels and requires no catheter insertion or contrast agent. We propose combining CINEMA with pseudo-continuous arterial spin labeling (PCASL). We present a preliminary study of non-contrast time-resolved MRA with time-of-arrival map and discuss its clinical relevance. Studies in all volunteers and patients clearly depicted major intracranial vessels. In patients, CINEMA-PCASL demonstrated the nidus, feeding arteries, and right posterior cerebral artery, and subsequent draining into the superficial venous system was clearly observed with a temporal resolution of 200 ms. Time-of-arrival maps presented the different filling time of every segment vessel in a single colorful image. The expected pattern of delayed transit to more distal vessels is apparent as well as the earlier arrival in central portions of larger vessels. This preliminary study demonstrated the usefulness of the CINEMA-PCASL technique in evaluating the cerebral vasculature. Simultaneous acquisition of high quality temporal and spatial resolutions obviated the need for contrast agent. (author)

  10. Non-contrast-enhanced 3D volumetric time-resolved MRA combining PCASL for intracranial vessels. President award proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Masanobu; Yoneyama, Masami; Tabuchi, Takashi; Tatsuno, Satoshi [Yaesu Clinic, Tokyo (Japan); Takemura, Atsushi; Obara, Makoto [Philips Electronics Japan, Tokyo (Japan); Takahara, Taro [Tokai Univ., Hiratsuka, Kanagawa (Japan)

    2013-02-15

    Hemodynamic information is required for accurate diagnosis, effective treatment, and follow-up examination of numerous cerebrovascular diseases. A recently introduced technique for non-contrast 3-dimensional (3D) volumetric time-resolved magnetic resonance angiography (MRA)-contrast inherent inflow enhanced multi phase angiography (CINEMA)-provides useful qualitative information on the morphologic and dynamic filling of intracranial vessels and requires no catheter insertion or contrast agent. We propose combining CINEMA with pseudo-continuous arterial spin labeling (PCASL). We present a preliminary study of non-contrast time-resolved MRA with time-of-arrival map and discuss its clinical relevance. Studies in all volunteers and patients clearly depicted major intracranial vessels. In patients, CINEMA-PCASL demonstrated the nidus, feeding arteries, and right posterior cerebral artery, and subsequent draining into the superficial venous system was clearly observed with a temporal resolution of 200 ms. Time-of-arrival maps presented the different filling time of every segment vessel in a single colorful image. The expected pattern of delayed transit to more distal vessels is apparent as well as the earlier arrival in central portions of larger vessels. This preliminary study demonstrated the usefulness of the CINEMA-PCASL technique in evaluating the cerebral vasculature. Simultaneous acquisition of high quality temporal and spatial resolutions obviated the need for contrast agent. (author)

  11. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  12. FUZZY BASED CONTRAST STRETCHING FOR MEDICAL IMAGE ENHANCEMENT

    Directory of Open Access Journals (Sweden)

    T.C. Raja Kumar

    2011-07-01

    Full Text Available Contrast Stretching is an important part in medical image processing applications. Contrast is the difference between two adjacent pixels. Fuzzy statistical values are analyzed and better results are produced in the spatial domain of the input image. The histogram mapping produces the resultant image with less impulsive noise and smooth nature. The probabilities of gray values are generated and the fuzzy set is determined from the position of the input image pixel. The result indicates the good performance of the proposed fuzzy based stretching. The inverse transform of the real values are mapped with the input image to generate the fuzzy statistics. This approach gives a flexible image enhancement for medical images in the presence of noises.

  13. Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification

    International Nuclear Information System (INIS)

    Looe, H.K.; Uphoff, Y.; Poppe, B.; Carl von Ossietzky Univ., Oldenburg; Harder, D.; Willborn, K.C.

    2012-01-01

    The quality of megavoltage clinical portal images is impaired by physical and geometrical effects. This image blurring can be corrected by a fast numerical two-dimensional (2D) deconvolution algorithm implemented in the electronic portal image device. We present some clinical examples of deconvolved portal images and evaluate the clinical advantages achieved by the improved sharpness and contrast. The principle of numerical 2D image deconvolution and the enhancement of sharpness and contrast thereby achieved are shortly explained. The key concept is the convolution kernel K(x,y), the mathematical equivalent of the smearing or blurring of a picture, and the computer-based elimination of this influence. Enhancements of sharpness and contrast were observed in all clinical portal images investigated. The images of fine bone structures were restored. The identification of organ boundaries and anatomical landmarks was improved, thereby permitting a more accurate comparison with the x-ray simulator radiographs. The visibility of prostate gold markers is also shown to be enhanced by deconvolution. The blurring effects of clinical portal images were eliminated by a numerical deconvolution algorithm that leads to better image sharpness and contrast. The fast algorithm permits the image blurring correction to be performed in real time, so that patient positioning verification with increased accuracy can be achieved in clinical practice. (orig.)

  14. Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification

    Energy Technology Data Exchange (ETDEWEB)

    Looe, H.K.; Uphoff, Y.; Poppe, B. [Pius Hospital, Oldenburg (Germany). Clinic for Radiation Therapy; Carl von Ossietzky Univ., Oldenburg (Germany). WG Medical Radiation Physics; Harder, D. [Georg August Univ., Goettingen (Germany). Medical Physics and Biophysics; Willborn, K.C. [Pius Hospital, Oldenburg (Germany). Clinic for Radiation Therapy

    2012-02-15

    The quality of megavoltage clinical portal images is impaired by physical and geometrical effects. This image blurring can be corrected by a fast numerical two-dimensional (2D) deconvolution algorithm implemented in the electronic portal image device. We present some clinical examples of deconvolved portal images and evaluate the clinical advantages achieved by the improved sharpness and contrast. The principle of numerical 2D image deconvolution and the enhancement of sharpness and contrast thereby achieved are shortly explained. The key concept is the convolution kernel K(x,y), the mathematical equivalent of the smearing or blurring of a picture, and the computer-based elimination of this influence. Enhancements of sharpness and contrast were observed in all clinical portal images investigated. The images of fine bone structures were restored. The identification of organ boundaries and anatomical landmarks was improved, thereby permitting a more accurate comparison with the x-ray simulator radiographs. The visibility of prostate gold markers is also shown to be enhanced by deconvolution. The blurring effects of clinical portal images were eliminated by a numerical deconvolution algorithm that leads to better image sharpness and contrast. The fast algorithm permits the image blurring correction to be performed in real time, so that patient positioning verification with increased accuracy can be achieved in clinical practice. (orig.)

  15. Villous adenoma of the common hepatic duct: the importance of contrast-enhanced ultrasound and endoscopic retrograde cholangiopancreatography for relevant diagnosis. A case report and review of the literature.

    Science.gov (United States)

    Tefas, Cristian; Tanţău, Marcel; Szenftleben, Alexandru; Chiorean, Liliana; Badea, Radu

    2015-12-01

    Adenomas are frequently encountered in the lower digestive tract but are rarely diagnosed in the biliary tree. We report a case of villous adenoma of the common hepatic duct. A 58-year old male was admitted with a four week history of intermittent upper right quadrant pain. Gray scale and contrast-enhanced abdominal ultrasound showed a mass inside the common hepatic duct with arterial enhancement and slow wash-out during the late venous phase. Subsequent endoscopic retrograde cholangiopancreatography and intraductal ultrasound confirmed the presence of the lesion. The final histopathological examination showed villous adenoma of the common hepatic duct with high-grade dysplasia. Contrast enhanced ultrasonography used in conjecture with endoscopic retrograde cholangiopancreatography can help in differentiating biliary tumors.

  16. The analysis of the contrast enhanced lesions on cerebro-vascular diseases

    International Nuclear Information System (INIS)

    Terada, Tomoaki; Nishiguchi, Takashi; Hyoutani, Genhachi; Miyamoto, Kazuki; Komai, Norihiko

    1989-01-01

    The contrast enhancement of cerebro-vascular diseases on CT is thought to be due to the increase of the cerebral blood volume (CBV) and/or the disruption of the blood brain barrier (BBB). However, it is difficult to differentiate these two conditions only by contrast enhanced CT. We employed dynamic CT (DCT) to analyse these lesions with respect to the patterns of time-density curve and peak height (PH) of the curve upon the theoretical basis that flattening of the latter part of the time-density curve reflected the degree of BBB disruption and PH reflected the CBV. In all cases of hypertensive intracerebral hemorrhage (11 cases), the contrast enhanced lesion around the hematoma showed marked BBB disruption according to the results of DCT. In 11 cases of cerebral infarction, patterns of BBB disruption and CBV varied at the contrast enhanced lesions according to the result of DCT. However, all contrast enhanced lesions with increased PH were associated with hemorrhagic infarction. Thus, the precise analysis of DCT provides appropriate therapeutic schedules by predicting the occurrence of hemorrhagic infarction. (author)

  17. Enhancement of Online Robotics Learning Using Real-Time 3D Visualization Technology

    OpenAIRE

    Richard Chiou; Yongjin (james) Kwon; Tzu-Liang (bill) Tseng; Robin Kizirian; Yueh-Ting Yang

    2010-01-01

    This paper discusses a real-time e-Lab Learning system based on the integration of 3D visualization technology with a remote robotic laboratory. With the emergence and development of the Internet field, online learning is proving to play a significant role in the upcoming era. In an effort to enhance Internet-based learning of robotics and keep up with the rapid progression of technology, a 3- Dimensional scheme of viewing the robotic laboratory has been introduced in addition to the remote c...

  18. On use of ultrasonography in obstetrics and gynecology

    International Nuclear Information System (INIS)

    Woo, Kwang Suk; Lee, Yong Woo

    1984-01-01

    Ultrasonography is playing an very important in diagnosis of normal pregnancy and the other diseases in the fields of obstetrics and gynecology. It is mainly used B-mode and Real time linear scan for pregnancy such as fetal movement during its early stage, fetal position, placenta location and biparietal diameter during its middle stage, and amniotic fluid and placenta previa during its late stage, as well as tumor accompanying pregnancy. Ultrasonography has been extensively used in the fields of obstetrics and gynecology for obtaining detailed images of soft tissues without hazard to the fetus and pregnant woman. In view of the need for its professionalism of high degree of skill, this treatise will introduce clinical instances and images obtained in the sonography room of the Seoul National University Hospital

  19. Effects of computed tomography contrast medium factors on contrast enhancement

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi; Okuda, Itsuko

    2011-01-01

    The various nonionic iodinated contrast media used in contrast computed tomography (CT) studies differ in terms of their composition, characteristics, and iodine concentration (mgI/ml), as well as the volume injected (ml). Compared with ionic iodinated contrast media, nonionic iodinated contrast media are low-osmolar agents, with different agents having different osmotic pressures. Using a custom-made phantom incorporating a semipermeable membrane, the osmotic flow rate (hounsfield unit (HU)/s) could easily be measured based on the observed increase in CT numbers, and the relationship between the osmotic pressure and the osmotic flow rate could be obtained (r 2 =0.84). In addition, taking the effects of patient size into consideration, the levels of contrast enhancement in the abdominal aorta (AA) and inferior vena cava (IVC) were compared among four types of CT contrast medium. The results showed differences in contrast enhancement in the IVC during the equilibrium phase depending on the type of contrast medium used. It was found that the factors responsible for the differences observed in enhancement in the IVC were the osmotic flow rate and the volume of the blood flow pathways in the circulatory system. It is therefore considered that the reproducibility of contrast enhancement is likely to be reduced in the examination of parenchymal organs, in which scanning must be performed during the equilibrium phase, even if the amount of iodine injected per unit body weight (mgI/kg) is maintained at a specified level. (author)

  20. Assessment of Oropharyngeal Dysphagia in Patients With Parkinson Disease: Use of Ultrasonography.

    Science.gov (United States)

    Oh, Eun Hyun; Seo, Jin Seok; Kang, Hyo Jung

    2016-04-01

    To compare tongue thickness, the shortest hyoid-thyroid approximation (distance between the hyoid bone and thyroid cartilage), and the time interval between the initiation of tongue movement and the time of the shortest hyoid-thyroid approximation, by using ultrasonography in healthy controls and patients with Parkinson disease (PD). Healthy controls and PD patients with dysphagia were compared. Ultrasonography was performed 3 times for the evaluation of tongue thickness, the shortest hyoid-thyroid approximation, and the time between the initiation of tongue movement and the shortest hyoid-thyroid approximation. A total of 24 healthy controls and 24 PD patients with dysphagia were enrolled. No significant differences were demonstrated between the two groups for the shortest hyoid-thyroid approximation (controls, 1.19±0.34 cm; PD patients, 1.37±0.5 cm; p=0.15) and tongue thickness (controls, 4.42±0.46 cm; PD patients, 4.27±0.51 cm; p=0.3). In contrast, the time to the shortest hyoid-thyroid approximation was significantly different between the two groups (controls, 1.53±0.87 ms; PD patients, 2.4±1.4 ms, p=0.048). Ultrasonography can be useful in evaluating dysphagia in patients with PD by direct visualization and measurement of the hyoid bone. Moreover, ultrasonography might contribute to a greater understanding of the pathophysiology of dysphagia in PD.

  1. MR imaging of the breast with Gd-DTPA enhancement

    International Nuclear Information System (INIS)

    Hachiya, Junichi; Seki, Tsuneaki; Okada, Minoru; Nitatori, Toshiaki; Korenaga, Tateo; Furuya, Yoshiro

    1991-01-01

    The accuracy of MR imaging with Gd-DTPA enhancement was compared with mammography and ultrasonography in 52 patients with clinically palpable benign and malignant breast masses (36 carcinomas, 2 malignant phyllodes tumors, 7 fibroadenomas, 7 cysts). On dynamic MR imaging, carcinomas and fibroadenomas were discriminated by their different dynamic enhancement profiles. In carcinomas, signal intensity increased rapidly, reaching a peak or plateau within 2 min after the injection of contrast medium. In fibroadenomas, signal intensity showed a much slower continuous increase without ceasing until about 8 min after injection. Malignant phyllodes tumors showed a dynamic enhancement profile identical to that of benign fibroadenomas. MR imaging correctly identified 84% of malignant tumors, 86% of fibroadenomas, and 100% of cysts, and was substantially more accurate in tissue characterization than mammography. The results of ultrasonography were highly similar to those of MR imaging. However, no single modality was infallible, and the three modalities were complementary rather than competitive. Considering the high cost and long examination time of MR imaging, mammography supplemented by ultrasonography seems to be the method of choice in the diagnosis of breast lesions. Nevertheless, MR imaging can add important information when the results of mammography and ultrasonography are insufficient or contradictory. (author)

  2. A real-time MTFC algorithm of space remote-sensing camera based on FPGA

    Science.gov (United States)

    Zhao, Liting; Huang, Gang; Lin, Zhe

    2018-01-01

    A real-time MTFC algorithm of space remote-sensing camera based on FPGA was designed. The algorithm can provide real-time image processing to enhance image clarity when the remote-sensing camera running on-orbit. The image restoration algorithm adopted modular design. The MTF measurement calculation module on-orbit had the function of calculating the edge extension function, line extension function, ESF difference operation, normalization MTF and MTFC parameters. The MTFC image filtering and noise suppression had the function of filtering algorithm and effectively suppressing the noise. The algorithm used System Generator to design the image processing algorithms to simplify the design structure of system and the process redesign. The image gray gradient dot sharpness edge contrast and median-high frequency were enhanced. The image SNR after recovery reduced less than 1 dB compared to the original image. The image restoration system can be widely used in various fields.

  3. Recent advances in contrast-enhanced magnetic resonance angiography

    International Nuclear Information System (INIS)

    Meaney, J.F.M.; Goyen, M.

    2007-01-01

    Magnetic resonance angiography (MRA) provides a means of visualizing vascular structures noninvasively and is increasingly replacing conventional X-ray angiography in routine use. Contrast-enhanced MRA (CE-MRA), in which gadolinium contrast agents are used to shorten the T1 relaxation, offers increased resolution and higher signal-to-noise ratio compared with earlier flow-dependent [time-of-flight (TOF) or phase-contrast (PC)] techniques. Currently available contrast agents differ in their ability to lower T1 values, and hence the choice of contrast agent is an important consideration in the successful use of CE-MRA. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first of a new class of intravascular contrast agents. This agent is extensively (approximately 85%) and reversibly bound to human serum albumin and is retained within the vasculature thus allowing steady-state imaging to be perform-ed. An additional benefit is that gado0fosveset offers higher relaxivity compared with other contrast agents, thus giving a lower blood T1 values which also makes it ideal for first-pass imaging. Clinical trials have consistently shown that gadofosveset enhanced MRA is more sensitive, specific and accurate than time-of-flight MRA, gives fewer uninterpretable scans and affords greater diagnostic confidence. Intravascular contrast agents such as gadofosveset, therefore, offer the potential for improved vascular imaging. (orig.)

  4. Contrast enhanced CT of spinal cord angioma

    International Nuclear Information System (INIS)

    Nakamura, Takahiko; Ebitani, Tsutomu; Honma, Takao; Sofue, Muroto; Nakamura, Shigeru

    1982-01-01

    Contrast enhanced CT on 6 patients with spinal cord angioma showed enhancement in 2 of them. The conditions to produce contrast enhancement were the window width of 100 - 200, and the window level of 0 - 50. In spinal cord angioma, contrast enhanced CT is presently only an adjunct to angiography and myelography. Nevertheless, contrast enhanced CT is useful in the screening test for spinal cord angioma, in the patients who are nonindicated to angiography, and in the postoperative follow-up. (Ueda, J.)

  5. Real-Time Fluorescence Detection in Aqueous Systems by Combined and Enhanced Photonic and Surface Effects in Patterned Hollow Sphere Colloidal Photonic Crystals.

    Science.gov (United States)

    Zhong, Kuo; Wang, Ling; Li, Jiaqi; Van Cleuvenbergen, Stijn; Bartic, Carmen; Song, Kai; Clays, Koen

    2017-05-16

    Hollow sphere colloidal photonic crystals (HSCPCs) exhibit the ability to maintain a high refractive index contrast after infiltration of water, leading to extremely high-quality photonic band gap effects, even in an aqueous (physiological) environment. Superhydrophilic pinning centers in a superhydrophobic environment can be used to strongly confine and concentrate water-soluble analytes. We report a strategy to realize real-time ultrasensitive fluorescence detection in patterned HSCPCs based on strongly enhanced fluorescence due to the photonic band-edge effect combined with wettability differentiation in the superhydrophobic/superhydrophilic pattern. The orthogonal nature of the two strategies allows for a multiplicative effect, resulting in an increase of two orders of magnitude in fluorescence.

  6. Computed tomography of hepatocellular carcinoma. Comparison with scintigraphy and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Kuniyuki; Nakata, Hajime; Honda, Hiroshi [University of Occupational and Environmental Health, Kitakyushu, Fukuoka (Japan)

    1983-09-01

    The detectability of hepatocellular carcinoma by computed tomography (CT) was evaluated on 76 cases. The detectability by plain CT was 93% with only slight improvement following a drip infusion of contrast medium. A comparison of scintigraphy, ultrasonography, and CT was also done on 63 cases. From the standpoint of the overall detectability of the tumor, CT was as good as ultrasonography or scintigraphy. Several cases were positive only on either CT or ultrasonography but no case was positive on scintigraphy alone. We believe that the combination of CT and ultrasonography is the most reliable as the screening method.

  7. Contrast-enhanced MR angiography of the carotid artery using 3D time-resolved imaging of contrast kinetics. Comparison with real-time fluoroscopic triggered 3D-elliptical centric view ordering

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Koshikawa, Tokiko; Fukatsu, Hiroshi; Sakurai, Yasuo; Ishiguchi, Tsuneo; Ishigaki, Takeo; Ichinose, Nobuyasu

    2001-01-01

    The purpose of this study was to evaluate contrast-enhanced MR angiography using the 3D time-resolved imaging of contrast kinetics technique (3D-TRICKS) by direct comparison with the fluoroscopic triggered 3D-elliptical centric view ordering (3D-ELLIP) technique. 3D-TRICKS and 3D-ELLIP were directly compared on a 1.5-Tesla MR unit using the same spatial resolution and matrix. In 3D-TRICKS, the central part of the k-space is updated more frequently than the peripheral part of the k-space, which is divided in the slice-encoding direction. The carotid arteries were imaged using 3D-TRICKS and 3D-ELLIP sequentially in 14 patients. Temporal resolution was 12 sec for 3D-ELLIP and 6 sec for 3D-TRICKS. The signal-to-noise ratio (S/N) of the common carotid artery was measured, and the quality of MIP images was then scored in terms of venous overlap and blurring of vessel contours. No significant difference in mean S/N was seen between the two methods. Significant venous overlap was not seen in any of the patients examined. Moderate blurring of vessel contours was noted on 3D-TRICKS in five patients and on 3D-ELLIP in four patients. Blurring in the slice-encoding direction was slightly more pronounced in 3D-TRICKS. However, qualitative analysis scores showed no significant differences. When the spatial resolution of the two methods was identical, the performance of 3D-TRICKS was found to be comparable in static visualization of the carotid arteries with 3D-ELLIP, although blurring in the slice-encoding direction was slightly more pronounced in 3D-TRICKS. 3D-TRICKS is a more robust technique than 3D-ELLIP, because 3D-ELLIP requires operator-dependent fluoroscopic triggering. Furthermore, 3D-TRICKS can achieve higher temporal resolution. For the spatial resolution employed in this study, 3D-TRICKS may be the method of choice. (author)

  8. Contrast agent enhanced pQCT of articular cartilage

    Energy Technology Data Exchange (ETDEWEB)

    Kallioniemi, A S [Department of Physics, University of Kuopio, POB 1627, 70211 Kuopio (Finland); Jurvelin, J S [Department of Physics, University of Kuopio, POB 1627, 70211 Kuopio (Finland); Nieminen, M T [Department of Diagnostic Radiology, POB 50, 90029 OYS, Oulu University Hospital, Oulu (Finland); Lammi, M J [Department of Anatomy, Institute of Biomedicine, University of Kuopio, POB 1627, 70211 Kuopio (Finland); Toeyraes, J [Department of Physics, University of Kuopio, POB 1627, 70211 Kuopio (Finland)

    2007-02-21

    The delayed gadolinium enhanced MRI of cartilage (dGEMRIC) technique is the only non-invasive means to estimate proteoglycan (PG) content in articular cartilage. In dGEMRIC, the anionic paramagnetic contrast agent gadopentetate distributes in inverse relation to negatively charged PGs, leading to a linear relation between T{sub 1,Gd} and spatial PG content in tissue. In the present study, for the first time, contrast agent enhanced peripheral quantitative computed tomography (pQCT) was applied, analogously to dGEMRIC, for the quantitative detection of spatial PG content in cartilage. The suitability of two anionic radiographic contrast agents, gadopentetate and ioxaglate, to detect enzymatically induced PG depletion in articular cartilage was investigated. First, the interrelationships of x-ray absorption, as measured with pQCT, and the contrast agent solution concentration were investigated. Optimal contrast agent concentrations for the following experiments were selected. Second, diffusion rates for both contrast agents were investigated in intact (n = 3) and trypsin-degraded (n 3) bovine patellar cartilage. The contrast agent concentration of the cartilaginous layer was measured prior to and 2-27 h after immersion. Optimal immersion time for the further experiments was selected. Third, the suitability of gadopentetate and ioxaglate enhanced pQCT to detect the enzymatically induced specific PG depletion was investigated by determining the contrast agent concentrations and uronic acid and water contents in digested and intact osteochondral samples (n = 16). After trypsin-induced PG loss (-70%, p < 0.05) the penetration of gadopentetate and ioxaglate increased (p < 0.05) by 34% and 48%, respectively. Gadopentetate and ioxaglate concentrations both showed strong correlation (r = -0.95, r -0.94, p < 0.01, respectively) with the uronic acid content. To conclude, contrast agent enhanced pQCT provides a technique to quantify PG content in normal and experimentally

  9. Contrast agent enhanced pQCT of articular cartilage

    Science.gov (United States)

    Kallioniemi, A. S.; Jurvelin, J. S.; Nieminen, M. T.; Lammi, M. J.; Töyräs, J.

    2007-02-01

    The delayed gadolinium enhanced MRI of cartilage (dGEMRIC) technique is the only non-invasive means to estimate proteoglycan (PG) content in articular cartilage. In dGEMRIC, the anionic paramagnetic contrast agent gadopentetate distributes in inverse relation to negatively charged PGs, leading to a linear relation between T1,Gd and spatial PG content in tissue. In the present study, for the first time, contrast agent enhanced peripheral quantitative computed tomography (pQCT) was applied, analogously to dGEMRIC, for the quantitative detection of spatial PG content in cartilage. The suitability of two anionic radiographic contrast agents, gadopentetate and ioxaglate, to detect enzymatically induced PG depletion in articular cartilage was investigated. First, the interrelationships of x-ray absorption, as measured with pQCT, and the contrast agent solution concentration were investigated. Optimal contrast agent concentrations for the following experiments were selected. Second, diffusion rates for both contrast agents were investigated in intact (n = 3) and trypsin-degraded (n = 3) bovine patellar cartilage. The contrast agent concentration of the cartilaginous layer was measured prior to and 2-27 h after immersion. Optimal immersion time for the further experiments was selected. Third, the suitability of gadopentetate and ioxaglate enhanced pQCT to detect the enzymatically induced specific PG depletion was investigated by determining the contrast agent concentrations and uronic acid and water contents in digested and intact osteochondral samples (n = 16). After trypsin-induced PG loss (-70%, p < 0.05) the penetration of gadopentetate and ioxaglate increased (p < 0.05) by 34% and 48%, respectively. Gadopentetate and ioxaglate concentrations both showed strong correlation (r = -0.95, r = -0.94, p < 0.01, respectively) with the uronic acid content. To conclude, contrast agent enhanced pQCT provides a technique to quantify PG content in normal and experimentally

  10. Contrast agent enhanced pQCT of articular cartilage

    International Nuclear Information System (INIS)

    Kallioniemi, A S; Jurvelin, J S; Nieminen, M T; Lammi, M J; Toeyraes, J

    2007-01-01

    The delayed gadolinium enhanced MRI of cartilage (dGEMRIC) technique is the only non-invasive means to estimate proteoglycan (PG) content in articular cartilage. In dGEMRIC, the anionic paramagnetic contrast agent gadopentetate distributes in inverse relation to negatively charged PGs, leading to a linear relation between T 1,Gd and spatial PG content in tissue. In the present study, for the first time, contrast agent enhanced peripheral quantitative computed tomography (pQCT) was applied, analogously to dGEMRIC, for the quantitative detection of spatial PG content in cartilage. The suitability of two anionic radiographic contrast agents, gadopentetate and ioxaglate, to detect enzymatically induced PG depletion in articular cartilage was investigated. First, the interrelationships of x-ray absorption, as measured with pQCT, and the contrast agent solution concentration were investigated. Optimal contrast agent concentrations for the following experiments were selected. Second, diffusion rates for both contrast agents were investigated in intact (n = 3) and trypsin-degraded (n 3) bovine patellar cartilage. The contrast agent concentration of the cartilaginous layer was measured prior to and 2-27 h after immersion. Optimal immersion time for the further experiments was selected. Third, the suitability of gadopentetate and ioxaglate enhanced pQCT to detect the enzymatically induced specific PG depletion was investigated by determining the contrast agent concentrations and uronic acid and water contents in digested and intact osteochondral samples (n = 16). After trypsin-induced PG loss (-70%, p < 0.05) the penetration of gadopentetate and ioxaglate increased (p < 0.05) by 34% and 48%, respectively. Gadopentetate and ioxaglate concentrations both showed strong correlation (r = -0.95, r -0.94, p < 0.01, respectively) with the uronic acid content. To conclude, contrast agent enhanced pQCT provides a technique to quantify PG content in normal and experimentally degraded

  11. Quantitative contrast-enhanced optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Winetraub, Yonatan; SoRelle, Elliott D. [Molecular Imaging Program at Stanford, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Bio-X Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Biophysics Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Structural Biology, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Liba, Orly [Molecular Imaging Program at Stanford, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Bio-X Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Structural Biology, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Electrical Engineering, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Zerda, Adam de la [Molecular Imaging Program at Stanford, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Bio-X Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Biophysics Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Structural Biology, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Electrical Engineering, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States)

    2016-01-11

    We have developed a model to accurately quantify the signals produced by exogenous scattering agents used for contrast-enhanced Optical Coherence Tomography (OCT). This model predicts distinct concentration-dependent signal trends that arise from the underlying physics of OCT detection. Accordingly, we show that real scattering particles can be described as simplified ideal scatterers with modified scattering intensity and concentration. The relation between OCT signal and particle concentration is approximately linear at concentrations lower than 0.8 particle per imaging voxel. However, at higher concentrations, interference effects cause signal to increase with a square root dependence on the number of particles within a voxel. Finally, high particle concentrations cause enough light attenuation to saturate the detected signal. Predictions were validated by comparison with measured OCT signals from gold nanorods (GNRs) prepared in water at concentrations ranging over five orders of magnitude (50 fM to 5 nM). In addition, we validated that our model accurately predicts the signal responses of GNRs in highly heterogeneous scattering environments including whole blood and living animals. By enabling particle quantification, this work provides a valuable tool for current and future contrast-enhanced in vivo OCT studies. More generally, the model described herein may inform the interpretation of detected signals in modalities that rely on coherence-based detection or are susceptible to interference effects.

  12. Contrast-enhanced MR angiography in Leriche's syndrome

    International Nuclear Information System (INIS)

    Link, J.; Steffens, J.C.; Brossmann, J.; Heller, M.; Loose, R.

    1998-01-01

    Purpose: To determine the usefulness of contrast-enhanced MR angiography for the diagnosis of Leriche's syndrome. Material and methods: Leriche's syndrome was seen in 7 patients via DSA. In [dition, contrast-enhanced MR angiography was performed (T R 7.8 ms/T E 2.1 ms, flip angle 30 , slab thickness 116 mm, slice thickness 1.82 mm, 64 partitions, FOV 500x438 mm, matrix 224x512). Results: Diagnosis of Leriche's syndrome was possible by contrast-enhanced MR angiography in each case. Visualisation of the femoral arteries was not possible in two patients by intraarterial DSA, in three other patients there was an insufficient contrast in the femoral arteries with DSA. Contrast-enhanced MR angiography revealed good visualisation of the femoral arteries in these patients. In [dition, contrast-enhanced MR angiography allowed complete visualisation of the patent lower limb arteries. In intraarterial DSA visualisation of the lower limb arteries was achieved reached in only one patient, but was incomplete. Conclusion: Contrast-enhanced MR angiography yielded the correct diagnosis of Leriche's syndrome in all 7 patients. Contrast-enhanced MR angiography was superior to DSA in the assessment of the distal run-off vessels in five of seven patients. (orig.) [de

  13. Comparison of Oral Contrast-Enhanced Transabdominal Ultrasound Imaging With Transverse Contrast-Enhanced Computed Tomography in Preoperative Tumor Staging of Advanced Gastric Carcinoma.

    Science.gov (United States)

    He, Xuemei; Sun, Jing; Huang, Xiaoling; Zeng, Chun; Ge, Yinggang; Zhang, Jun; Wu, Jingxian

    2017-12-01

    This study assessed the diagnostic performance of transabdominal oral contrast-enhanced ultrasound (US) imaging for preoperative tumor staging of advanced gastric carcinoma by comparing it with transverse contrast-enhanced computed tomography (CT). This retrospective study included 42 patients with advanced gastric cancer who underwent laparoscopy, radical surgery, or palliative surgery because of serious complications and had a body mass index of less than 25 kg/m 2 . A cereal-based oral contrast agent was used for transabdominal oral contrast-enhanced US. Retrospective analyses were conducted using preoperative tumor staging data acquired by either transabdominal oral contrast-enhanced US or transverse contrast-enhanced CT. Both contrast-enhanced US and contrast-enhanced CT examinations were reviewed by 2 experienced radiologists independently for preoperative tumor staging according to the seventh edition of the TNM classification. The accuracy, sensitivity, and specificity were calculated by comparing the results of contrast-enhanced US and contrast-enhanced CT with pathologic findings. The overall accuracies of the imaging modalities were compared by the McNemar test. No significant difference was noted in the overall accuracy of transabdominal oral contrast-enhanced US (86% [36 of 42]) and transverse contrast-enhanced CT (83% [35 of 42] P > .999). For stage T2 to T4 gastric cancer, the accuracies of transabdominal oral contrast-enhanced US were 88%, 86%, and 98%, respectively, and those of transverse contrast-enhanced CT were 93%, 83%, and 90%. The overall accuracy of transabdominal oral contrast-enhanced US was comparable with that of transverse contrast-enhanced CT for preoperative tumor staging of advanced gastric cancer. © 2017 by the American Institute of Ultrasound in Medicine.

  14. Real-time flight test data distribution and display

    Science.gov (United States)

    Nesel, Michael C.; Hammons, Kevin R.

    1988-01-01

    Enhancements to the real-time processing and display systems of the NASA Western Aeronautical Test Range are described. Display processing has been moved out of the telemetry and radar acquisition processing systems super-minicomputers into user/client interactive graphic workstations. Real-time data is provided to the workstations by way of Ethernet. Future enhancement plans include use of fiber optic cable to replace the Ethernet.

  15. Enhancing the Quality of Service for Real Time Traffic over Optical Burst Switching (OBS Networks with Ensuring the Fairness for Other Traffics.

    Directory of Open Access Journals (Sweden)

    Mohammed A Al-Shargabi

    Full Text Available Optical burst switching (OBS networks have been attracting much consideration as a promising approach to build the next generation optical Internet. A solution for enhancing the Quality of Service (QoS for high priority real time traffic over OBS with the fairness among the traffic types is absent in current OBS' QoS schemes. In this paper we present a novel Real Time Quality of Service with Fairness Ratio (RT-QoSFR scheme that can adapt the burst assembly parameters according to the traffic QoS needs in order to enhance the real time traffic QoS requirements and to ensure the fairness for other traffic. The results show that RT-QoSFR scheme is able to fulfill the real time traffic requirements (end to end delay, and loss rate ensuring the fairness for other traffics under various conditions such as the type of real time traffic and traffic load. RT-QoSFR can guarantee that the delay of the real time traffic packets does not exceed the maximum packets transfer delay value. Furthermore, it can reduce the real time traffic packets loss, at the same time guarantee the fairness for non real time traffic packets by determining the ratio of real time traffic inside the burst to be 50-60%, 30-40%, and 10-20% for high, normal, and low traffic loads respectively.

  16. Evaluation of delayed contrast-enhanced CT scan in diagnosing hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Li Jianding; Liang Chenyang; Zhang Hua; Zhang Yuezhen; Li Rui

    2001-01-01

    Objective: To assess the diagnostic value of delayed CT contrast enhancement patterns in hilar cholangiocarcinoma based on two-phased dynamic incremental CT scanning. Methods: Fifty-two patients with suspected hilar tumor and bile duct obstruction underwent spiral CT scan. The scan time for one revolution of the X-ray tube was 1 second. To elucidate the delay time for optimal imaging, all proved cholangiocarcinoma with delayed (6, 8, 10, 15, 20, 30 minutes) post-equilibrium-phase contrast-enhanced CT scans were acquired with unenhanced, dynamic contrast-enhanced, and delayed images. Degree of delayed enhancement was compared with that of surrounding liver parenchyma. Results: (1) 8-15 minutes after IV injection of contrast material was the delay time for optimal imaging. (2) Of 29 cholangiocarcinomas, the early CT showed hypo-attenuating (lower than that of liver parenchyma) in 23 tumors, iso-attenuating (equal to that of the liver) in 4 tumors, and hyper-attenuating (higher than that of liver) in 2 tumors. The delayed CT scan showed iso-attenuating in 8 tumors, hyper-attenuating in 21 tumors, and no hypo-attenuating. Most of delay imaging of hilar cholangiocarcinoma may appear hyper-attenuating (U = -4.3073, P 2 = 9.09, P < 0.01). Conclusion: When assessing hilar tumor, delayed CT contrast enhancement patterns based on two-phase dynamic incremental CT scans is useful in the detection and characterization of hilar cholangiocarcinoma

  17. All-phase MR angiography using independent component analysis of dynamic contrast enhanced MRI time series. φ-MRA

    International Nuclear Information System (INIS)

    Suzuki, Kiyotaka; Matsuzawa, Hitoshi; Watanabe, Masaki; Nakada, Tsutomu; Nakayama, Naoki; Kwee, I.L.

    2003-01-01

    Dynamic contrast enhanced magnetic resonance imaging (dynamic MRI) represents a MRI version of non-diffusible tracer methods, the main clinical use of which is the physiological construction of what is conventionally referred to as perfusion images. The raw data utilized for constructing MRI perfusion images are time series of pixel signal alterations associated with the passage of a gadolinium containing contrast agent. Such time series are highly compatible with independent component analysis (ICA), a novel statistical signal processing technique capable of effectively separating a single mixture of multiple signals into their original independent source signals (blind separation). Accordingly, we applied ICA to dynamic MRI time series. The technique was found to be powerful, allowing for hitherto unobtainable assessment of regional cerebral hemodynamics in vivo. (author)

  18. Intrahepatic portal-hepatic venous shunt diagnosed by ultrasonography and computed tomography

    International Nuclear Information System (INIS)

    Shinagawa, Takashi; Iino, Yasuo; Ukaji, Haruyasu; Ishizuka, Masaharu

    1986-01-01

    Two cases of intrahepatic portal-hepatic venous shunt found by ultrasonography and computed tomography are reported. The first case came to the hospital because of hematuria. A large shunt between the portal vein and the hepatic vein was demonstrated by ultrasonography done for screening, and confirmed by percutaneous transhepatic portography (PTP). The second case was admitted because of cholelithiasis. Computed tomography with contrast enhancement revealed a dilated portal vein in the upper portion of the right lobe. It was subsequently shown by PTP to be a portal-hepatic venous shunt. Portal vein pressure and histological finding of the liver were normal in both cases. The etiology of the shunt was thought to be congenital in these cases for lack of liver disease, portal hypertension and history of trauma. Both cases had no history of hepatic encephalopathy and did not show any symptom attributable to the shunt. (author)

  19. Quantitative analysis of the improvement in high zoom maritime tracking due to real-time image enhancement

    CSIR Research Space (South Africa)

    Bachoo, AK

    2011-04-01

    Full Text Available This work aims to evaluate the improvement in the performance of tracking small maritime targets due to real-time enhancement of the video streams from high zoom cameras on pan-tilt pedestal. Due to atmospheric conditions these images can frequently...

  20. Real-time implementations of acoustic signal enhancement techniques for aerial based surveillance and rescue applications

    Science.gov (United States)

    Ramos, Antonio L. L.; Shao, Zhili; Holthe, Aleksander; Sandli, Mathias F.

    2017-05-01

    The introduction of the System-on-Chip (SoC) technology has brought exciting new opportunities for the development of smart low cost embedded systems spanning a wide range of applications. Currently available SoC devices are capable of performing high speed digital signal processing tasks in software while featuring relatively low development costs and reduced time-to-market. Unmanned aerial vehicles (UAV) are an application example that has shown tremendous potential in an increasing number of scenarios, ranging from leisure to surveillance as well as in search and rescue missions. Video capturing from UAV platforms is a relatively straightforward task that requires almost no preprocessing. However, that does not apply to audio signals, especially in cases where the data is to be used to support real-time decision making. In fact, the enormous amount of acoustic interference from the surroundings, including the noise from the UAVs propellers, becomes a huge problem. This paper discusses a real-time implementation of the NLMS adaptive filtering algorithm applied to enhancing acoustic signals captured from UAV platforms. The model relies on a combination of acoustic sensors and a computational inexpensive algorithm running on a digital signal processor. Given its simplicity, this solution can be incorporated into the main processing system of an UAV using the SoC technology, and run concurrently with other required tasks, such as flight control and communications. Simulations and real-time DSP-based implementations have shown significant signal enhancement results by efficiently mitigating the interference from the noise generated by the UAVs propellers as well as from other external noise sources.

  1. Examination of hepatic contrast-enhanced CT monitored by Smart Prep

    International Nuclear Information System (INIS)

    Kakizaki, Dai; Saito, Kazuhiro; Sakurada, Toru; Abe, Kimihiko; Suzuki, Kenji

    1999-01-01

    The aim of the present study is to obtain the time density curves of the contrast-enhanced CT of hepatic portal vein, hepatic and splenic parenchyma, and to examine the relation with age, body weight, type of liver dysfunction. Subjects were 32 patients with liver tumors or liver diseases. For this purpose, the procedure of hepatic CT was monitored by Smart Prep and the images of whole liver was taken when the level of the contrast at the hepatic portal vein reached to the enhancement threshold. The contrast medium used was Iomeprol 300. The adverse reactions by Iomeprol 300 were mild and any treatment did not need. There was no correlation age and weight with enhancement threshold at the hepatic portal vein and peak time at the splenic parenchyma. The enhancement threshold at the hepatic portal vein was various in patients with chrrhosis and chronic hepatitis, and tended to be delayed in patients with chrrhosis. The peak time of the splenic parenchyma was up to 52 seconds in all patients with chronic hepatitis. The shortage of the enhancement threshold and the increase in blood flow at arterial early phase were observed in the patients with advanced acute hepatitis. This method should be examined more cases with various hepatic diseases. (K.H.)

  2. Quantitative (real-time) PCR

    International Nuclear Information System (INIS)

    Denman, S.E.; McSweeney, C.S.

    2005-01-01

    Many nucleic acid-based probe and PCR assays have been developed for the detection tracking of specific microbes within the rumen ecosystem. Conventional PCR assays detect PCR products at the end stage of each PCR reaction, where exponential amplification is no longer being achieved. This approach can result in different end product (amplicon) quantities being generated. In contrast, using quantitative, or real-time PCR, quantification of the amplicon is performed not at the end of the reaction, but rather during exponential amplification, where theoretically each cycle will result in a doubling of product being created. For real-time PCR, the cycle at which fluorescence is deemed to be detectable above the background during the exponential phase is termed the cycle threshold (Ct). The Ct values obtained are then used for quantitation, which will be discussed later

  3. Advantages of time-resolved contrast-enhanced 4D MR angiography in splenic arterial steal syndrome.

    Science.gov (United States)

    Obmann, Verena C; Chalian, Majid; Mansoori, Bahar; Sanchez, Edmund; Gulani, Vikas

    2018-03-07

    Splenic artery steal syndrome (SASS) is a severe complication affecting up to 10% of orthotopic liver transplant (OLT) patients. In this case report, we present a 35-year-old male with OLT secondary to liver failure due to hemochromatosis, who developed SASS. We describe potential application of different imaging techniques for diagnosis of SASS with focus on the value of time-resolved contrast enhanced 4D magnetic resonance angiography (MRA). Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Contrast-enhanced spectral mammography (CESM) and contrast enhanced MRI (CEMRI): Patient preferences and tolerance.

    Science.gov (United States)

    Hobbs, Max M; Taylor, Donna B; Buzynski, Sebastian; Peake, Rachel E

    2015-06-01

    Contrast-enhanced spectral mammography (CESM) may have similar diagnostic performance to Contrast-enhanced MRI (CEMRI) in the diagnosis and staging of breast cancer. To date, research has focused exclusively on diagnostic performance when comparing these two techniques. Patient experience is also an important factor when comparing and deciding on which of these modalities is preferable. The aim of this study is to compare patient experience of CESM against CEMRI during preoperative breast cancer staging. Forty-nine participants who underwent both CESM and CEMRI, as part of a larger trial, completed a Likert questionnaire about their preference for each modality according to the following criteria: comfort of breast compression, comfort of intravenous (IV) contrast injection, anxiety and overall preference. Participants also reported reasons for preferring one modality to the other. Quantitative data were analysed using a Wilcoxon sign-rank test and chi-squared test. Qualitative data are reported descriptively. A significantly higher overall preference towards CESM was demonstrated (n = 49, P < 0.001), with faster procedure time, greater comfort and lower noise level cited as the commonest reasons. Participants also reported significantly lower rates of anxiety during CESM compared with CEMRI (n = 36, P = 0.009). A significantly higher rate of comfort was reported during CEMRI for measures of breast compression (n = 49, P = 0.001) and the sensation of IV contrast injection (n = 49, P = 0.003). Our data suggest that overall, patients prefer the experience of CESM to CEMRI, adding support for the role of CESM as a possible alternative to CEMRI for breast cancer staging. © 2015 The Royal Australian and New Zealand College of Radiologists.

  5. Contrast-enhanced spectral mammography (CESM) and contrast enhanced MRI (CEMRI): Patient preferences and tolerance

    International Nuclear Information System (INIS)

    Hobbs, Max; Buzynski, Sebastian; Taylor, Donna B.; Peake, Rachel E.

    2015-01-01

    Contrast-enhanced spectral mammography (CESM) may have similar diagnostic performance to Contrast-enhanced MRI (CEMRI) in the diagnosis and staging of breast cancer. To date, research has focused exclusively on diagnostic performance when comparing these two techniques. Patient experience is also an important factor when comparing and deciding on which of these modalities is preferable. The aim of this study is to compare patient experience of CESM against CEMRI during preoperative breast cancer staging. Forty-nine participants who underwent both CESM and CEMRI, as part of a larger trial, completed a Likert questionnaire about their preference for each modality according to the following criteria: comfort of breast compression, comfort of intravenous (IV) contrast injection, anxiety and overall preference. Participants also reported reasons for preferring one modality to the other. Quantitative data were analysed using a Wilcoxon sign-rank test and chi-squared test. Qualitative data are reported descriptively. A significantly higher overall preference towards CESM was demonstrated (n = 49, P < 0.001), with faster procedure time, greater comfort and lower noise level cited as the commonest reasons. Participants also reported significantly lower rates of anxiety during CESM compared with CEMRI (n = 36, P = 0.009). A significantly higher rate of comfort was reported during CEMRI for measures of breast compression (n = 49, P = 0.001) and the sensation of IV contrast injection (n = 49, P = 0.003). Our data suggest that overall, patients prefer the experience of CESM to CEMRI, adding support for the role of CESM as a possible alternative to CEMRI for breast cancer staging.

  6. Improvement of observer performance during fluoroscopy by local adaptive contrast enhancement

    International Nuclear Information System (INIS)

    Gould, R.G.; Demas, B.E.; Maroney, T.P.

    1988-01-01

    The ability of a video processor (FluoroVision FV-1), which performs two-dimensional locally adaptive contrast enhancement, to improve the detection of a low-contrast object was evaluated by means of receiver operating characteristic (ROC) curves. Three independent observers viewed a videotape of 50 fluoroscopic images of a varied background, in which a test object was present in 25. Each observer viewed the tape under four conditions: (1) no processing, (2) temporal noise reduction (gaussian weighted time averaging, (3) contrast enhancement, and (4) both noise reduction and contrast enhancement. The results were that detection was significantly improved by the locally adaptive contrast enhancement. Noise reduction did not significantly improve performance, probably because washer detection was limited by background contrast variations as well as noise and because only a small amount of noise reduction was used. The authors conclude that the processing device is potentially valuable in improving the quality of clinical fluoroscopic images

  7. Soft-tissue tumor differentiation using 3D power Doppler ultrasonography with echo-contrast medium injection.

    Science.gov (United States)

    Chiou, Hong-Jen; Chou, Yi-Hong; Chen, Wei-Ming; Chen, Winby; Wang, Hsin-Kai; Chang, Cheng-Yen

    2010-12-01

    We aimed to evaluate the ability of 3-dimensional power Doppler ultrasonography to differentiate soft-tissue masses from blood flow and vascularization with contrast medium. Twenty-five patients (mean age, 44.1 years; range, 12-77 years) with a palpable mass were enrolled in this study. Volume data were acquired using linear and convex 3-dimensional probes and contrast medium injected manually by bolus. Data were stored and traced slice by slice for 12 slices. All patients were scanned by the same senior sonologist. The vascular index (VI), flow index (FI), and vascular-flow index (VFI) were automatically calculated after the tumor was completely traced. All tumors were later confirmed by pathology. The study included 8 benign (mean, 36.5 mL; range, 2.4-124 mL) and 17 malignant (mean, 319.4 mL; range, 9.9-1,179.6 mL) tumors. Before contrast medium injection, mean VI, FI and VFI were, respectively, 3.22, 32.26 and 1.07 in benign tumors, and 1.97, 29.33 and 0.67 in malignant tumors. After contrast medium injection, they were, respectively, 20.85, 37.33 and 8.52 in benign tumors, and 40.12, 41.21 and 17.77 in malignant tumors. The mean differences between with and without contrast injection for VI, FI and VFI were, respectively, 17.63, 5.07 and 7.45 in benign tumors, and 38.15, 11.88 and 16.55 in malignant tumors. Tumor volume, VI, FI and VFI were not significantly different between benign and malignant tumors before and after echo-contrast medium injection. However, VI, FI and VFI under self-differentiation (differences between with and without contrast injection) were significantly different between malignant and benign tumors. Three-dimensional power Doppler ultrasound is a valuable tool for differential diagnosis of soft-tissue tumors, especially with the injection of an echo-contrast medium. Copyright © 2010 Elsevier. Published by Elsevier B.V. All rights reserved.

  8. Enhanced least squares Monte Carlo method for real-time decision optimizations for evolving natural hazards

    DEFF Research Database (Denmark)

    Anders, Annett; Nishijima, Kazuyoshi

    The present paper aims at enhancing a solution approach proposed by Anders & Nishijima (2011) to real-time decision problems in civil engineering. The approach takes basis in the Least Squares Monte Carlo method (LSM) originally proposed by Longstaff & Schwartz (2001) for computing American option...... prices. In Anders & Nishijima (2011) the LSM is adapted for a real-time operational decision problem; however it is found that further improvement is required in regard to the computational efficiency, in order to facilitate it for practice. This is the focus in the present paper. The idea behind...... the improvement of the computational efficiency is to “best utilize” the least squares method; i.e. least squares method is applied for estimating the expected utility for terminal decisions, conditional on realizations of underlying random phenomena at respective times in a parametric way. The implementation...

  9. Deep architecture neural network-based real-time image processing for image-guided radiotherapy.

    Science.gov (United States)

    Mori, Shinichiro

    2017-08-01

    To develop real-time image processing for image-guided radiotherapy, we evaluated several neural network models for use with different imaging modalities, including X-ray fluoroscopic image denoising. Setup images of prostate cancer patients were acquired with two oblique X-ray fluoroscopic units. Two types of residual network were designed: a convolutional autoencoder (rCAE) and a convolutional neural network (rCNN). We changed the convolutional kernel size and number of convolutional layers for both networks, and the number of pooling and upsampling layers for rCAE. The ground-truth image was applied to the contrast-limited adaptive histogram equalization (CLAHE) method of image processing. Network models were trained to keep the quality of the output image close to that of the ground-truth image from the input image without image processing. For image denoising evaluation, noisy input images were used for the training. More than 6 convolutional layers with convolutional kernels >5×5 improved image quality. However, this did not allow real-time imaging. After applying a pair of pooling and upsampling layers to both networks, rCAEs with >3 convolutions each and rCNNs with >12 convolutions with a pair of pooling and upsampling layers achieved real-time processing at 30 frames per second (fps) with acceptable image quality. Use of our suggested network achieved real-time image processing for contrast enhancement and image denoising by the use of a conventional modern personal computer. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. Enhancement pattern of hilar cholangiocarcinoma: Contrast-enhanced ultrasound versus contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    Xu Huixiong; Chen Lida; Xie Xiaoyan; Xie Xiaohua; Xu Zuofeng; Liu Guangjian; Lin Manxia; Wang Zhu; Lu Mingde

    2010-01-01

    Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% (16/19) for baseline ultrasound, 89.5% (17/19) for CEUS, and 78.9% (15/19) for CECT (all P > 0.05 between every two groups). CEUS significantly improved the lesion conspicuity in comparison with CECT. CEUS and CECT made correct diagnoses in 30 (93.8%) and 25 (78.1%) lesions prior to pathological examination (P = 0.125). Conclusion: The enhancement pattern of hilar cholangiocarcinoma on CEUS was similar with that on CECT in arterial phase, whereas in portal phase hilar cholangiocarcinoma shows hypoenhancement more likely on CEUS. CEUS and CECT lead to similar results in evaluating portal vein infiltration and diagnosis of this entity.

  11. Enhancement pattern of hilar cholangiocarcinoma: Contrast-enhanced ultrasound versus contrast-enhanced computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Xu Huixiong, E-mail: xuhuixiong@hotmail.co [Department of Medical Ultrasonics, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou 510080 (China); Chen Lida; Xie Xiaoyan; Xie Xiaohua; Xu Zuofeng; Liu Guangjian; Lin Manxia; Wang Zhu [Department of Medical Ultrasonics, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou 510080 (China); Lu Mingde, E-mail: lumd@21cn.co [Department of Hepatobiliary Surgery, First Affiliated Hospital, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou 510080 (China)

    2010-08-15

    Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% (16/19) for baseline ultrasound, 89.5% (17/19) for CEUS, and 78.9% (15/19) for CECT (all P > 0.05 between every two groups). CEUS significantly improved the lesion conspicuity in comparison with CECT. CEUS and CECT made correct diagnoses in 30 (93.8%) and 25 (78.1%) lesions prior to pathological examination (P = 0.125). Conclusion: The enhancement pattern of hilar cholangiocarcinoma on CEUS was similar with that on CECT in arterial phase, whereas in portal phase hilar cholangiocarcinoma shows hypoenhancement more likely on CEUS. CEUS and CECT lead to similar results in evaluating portal vein infiltration and diagnosis of this entity.

  12. Dynamic contrast-enhanced magnetic resonance imaging of the wrist in children with juvenile idiopathic arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Nusman, Charlotte M. [Emma Children' s Hospital, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Academic Medical Center, Amsterdam (Netherlands); Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Lavini, Cristina; Hemke, Robert; Caan, Matthan W.A.; Maas, Mario [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Schonenberg-Meinema, Dieneke; Berg, J.M. van den; Kuijpers, Taco W. [Emma Children' s Hospital, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Academic Medical Center, Amsterdam (Netherlands); Dolman, Koert M. [Sint Lucas Andreas Hospital, Department of Pediatrics, Amsterdam (Netherlands); Reade Institute location Jan van Breemen, Department of Pediatric Rheumatology, Amsterdam (Netherlands); Rossum, Marion A.J. van [Reade Institute location Jan van Breemen, Department of Pediatric Rheumatology, Amsterdam (Netherlands); Emma Children' s Hospital, Department of Pediatrics, Academic Medical Center, Amsterdam (Netherlands)

    2017-02-15

    Dynamic contrast-enhanced MRI provides information on the heterogeneity of the synovium, the primary target of disease in children with juvenile idiopathic arthritis (JIA). To evaluate the feasibility of dynamic contrast-enhanced MRI in the wrist of children with JIA using conventional descriptive measures and time-intensity-curve shape analysis. To explore the association between enhancement characteristics and clinical disease status. Thirty-two children with JIA and wrist involvement underwent dynamic contrast-enhanced MRI with movement-registration and were classified using validated criteria as clinically active (n = 27) or inactive (n = 5). Outcome measures included descriptive parameters and the classification into time-intensity-curve shapes, which represent the patterns of signal intensity change over time. Differences in dynamic contrast-enhanced MRI outcome measures between clinically active and clinically inactive disease were analyzed and correlation with the Juvenile Arthritis Disease Activity Score was determined. Comprehensive evaluation of disease status was technically feasible and the quality of the dynamic dataset was improved by movement registration. The conventional descriptive measure maximum enhancement differed significantly between clinically active and inactive disease (P = 0.019), whereas time-intensity-curve shape analysis showed no differences. Juvenile Arthritis Disease Activity Score correlated moderately with enhancing volume (P = 0.484). Dynamic contrast-enhanced MRI is a promising biomarker for evaluating disease status in children with JIA and wrist involvement. Conventional descriptive dynamic contrast-enhanced MRI measures are better associated with clinically active disease than time-intensity-curve shape analysis. (orig.)

  13. Real-time simulation of large-scale floods

    Science.gov (United States)

    Liu, Q.; Qin, Y.; Li, G. D.; Liu, Z.; Cheng, D. J.; Zhao, Y. H.

    2016-08-01

    According to the complex real-time water situation, the real-time simulation of large-scale floods is very important for flood prevention practice. Model robustness and running efficiency are two critical factors in successful real-time flood simulation. This paper proposed a robust, two-dimensional, shallow water model based on the unstructured Godunov- type finite volume method. A robust wet/dry front method is used to enhance the numerical stability. An adaptive method is proposed to improve the running efficiency. The proposed model is used for large-scale flood simulation on real topography. Results compared to those of MIKE21 show the strong performance of the proposed model.

  14. Left Gastric Vein Visualization with Hepatopetal Flow Information in Healthy Subjects Using Non-Contrast-Enhanced Magnetic Resonance Angiography with Balanced Steady-State Free-Precession Sequence and Time-Spatial Labeling Inversion Pulse.

    Science.gov (United States)

    Furuta, Akihiro; Isoda, Hiroyoshi; Ohno, Tsuyoshi; Ono, Ayako; Yamashita, Rikiya; Arizono, Shigeki; Kido, Aki; Sakashita, Naotaka; Togashi, Kaori

    2018-01-01

    To selectively visualize the left gastric vein (LGV) with hepatopetal flow information by non-contrast-enhanced magnetic resonance angiography under a hypothesis that change in the LGV flow direction can predict the development of esophageal varices; and to optimize the acquisition protocol in healthy subjects. Respiratory-gated three-dimensional balanced steady-state free-precession scans were conducted on 31 healthy subjects using two methods (A and B) for visualizing the LGV with hepatopetal flow. In method A, two time-spatial labeling inversion pulses (Time-SLIP) were placed on the whole abdomen and the area from the gastric fornix to the upper body, excluding the LGV area. In method B, nonselective inversion recovery pulse was used and one Time-SLIP was placed on the esophagogastric junction. The detectability and consistency of LGV were evaluated using the two methods and ultrasonography (US). Left gastric veins by method A, B, and US were detected in 30 (97%), 24 (77%), and 23 (74%) subjects, respectively. LGV flow by US was hepatopetal in 22 subjects and stagnant in one subject. All hepatopetal LGVs by US coincided with the visualized vessels in both methods. One subject with non-visualized LGV in method A showed stagnant LGV by US. Hepatopetal LGV could be selectively visualized by method A in healthy subjects.

  15. A real-time remote video streaming platform for ultrasound imaging.

    Science.gov (United States)

    Ahmadi, Mehdi; Gross, Warren J; Kadoury, Samuel

    2016-08-01

    Ultrasound is a viable imaging technology in remote and resources-limited areas. Ultrasonography is a user-dependent skill which depends on a high degree of training and hands-on experience. However, there is a limited number of skillful sonographers located in remote areas. In this work, we aim to develop a real-time video streaming platform which allows specialist physicians to remotely monitor ultrasound exams. To this end, an ultrasound stream is captured and transmitted through a wireless network into remote computers, smart-phones and tablets. In addition, the system is equipped with a camera to track the position of the ultrasound probe. The main advantage of our work is using an open source platform for video streaming which gives us more control over streaming parameters than the available commercial products. The transmission delays of the system are evaluated for several ultrasound video resolutions and the results show that ultrasound videos close to the high-definition (HD) resolution can be received and displayed on an Android tablet with the delay of 0.5 seconds which is acceptable for accurate real-time diagnosis.

  16. D Model Visualization Enhancements in Real-Time Game Engines

    Science.gov (United States)

    Merlo, A.; Sánchez Belenguer, C.; Vendrell Vidal, E.; Fantini, F.; Aliperta, A.

    2013-02-01

    This paper describes two procedures used to disseminate tangible cultural heritage through real-time 3D simulations providing accurate-scientific representations. The main idea is to create simple geometries (with low-poly count) and apply two different texture maps to them: a normal map and a displacement map. There are two ways to achieve models that fit with normal or displacement maps: with the former (normal maps), the number of polygons in the reality-based model may be dramatically reduced by decimation algorithms and then normals may be calculated by rendering them to texture solutions (baking). With the latter, a LOD model is needed; its topology has to be quad-dominant for it to be converted to a good quality subdivision surface (with consistent tangency and curvature all over). The subdivision surface is constructed using methodologies for the construction of assets borrowed from character animation: these techniques have been recently implemented in many entertainment applications known as "retopology". The normal map is used as usual, in order to shade the surface of the model in a realistic way. The displacement map is used to finish, in real-time, the flat faces of the object, by adding the geometric detail missing in the low-poly models. The accuracy of the resulting geometry is progressively refined based on the distance from the viewing point, so the result is like a continuous level of detail, the only difference being that there is no need to create different 3D models for one and the same object. All geometric detail is calculated in real-time according to the displacement map. This approach can be used in Unity, a real-time 3D engine originally designed for developing computer games. It provides a powerful rendering engine, fully integrated with a complete set of intuitive tools and rapid workflows that allow users to easily create interactive 3D contents. With the release of Unity 4.0, new rendering features have been added, including Direct

  17. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  18. Nanoparticles as image enhancing agents for ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Liu Jun [Biomedical Engineering Department, Ohio State University, 270 Bevis Hall, 1080 Carmack Rd, Columbus, OH 43210 (United States); Levine, Andrea L [Department of Veterinary Biosciences, Ohio State University, 1925 Coffey Rd, Columbus, OH 43210 (United States); Mattoon, John S [Department of Veterinary Clinical Sciences, Ohio State University, 1151 Veterinary Hospital, 601 Vernon Tharp St., Columbus, OH 43210 (United States); Yamaguchi, Mamoru [Department of Veterinary Biosciences, Ohio State University, 1925 Coffey Rd, Columbus, OH 43210 (United States); Lee, Robert J [Division of Pharmaceutics, College of Pharmacy, NCI Comprehensive Cancer Center, and NSF Nanoscale Science and Engineering Center, Ohio State University, 500 West 12th Avenue, Columbus, OH 43210 (United States); Pan Xueliang [Department of Statistics, Ohio State University, 1958 Neil Avenue, Columbus, OH 43210 (United States); Rosol, Thomas J [Department of Veterinary Biosciences, Ohio State University, 1925 Coffey Rd, Columbus, OH 43210 (United States)

    2006-05-07

    Nanoparticles have drawn great attention as targeted imaging and/or therapeutic agents. The small size of the nanoparticles allows them to target cells that are beyond capillary vasculature, such as cancer cells. We investigated the effect of solid nanoparticles for enhancing ultrasonic grey scale images in tissue phantoms and mouse livers in vivo. Silica nanospheres (100 nm) were dispersed in agarose at 1-2.5% mass concentration and imaged by a high-resolution ultrasound imaging system (transducer centre frequency: 30 MHz). Polystyrene particles of different sizes (500-3000 nm) and concentrations (0.13-0.75% mass) were similarly dispersed in agarose and imaged. Mice were injected intravenously with nanoparticle suspensions in saline. B-mode images of the livers were acquired at different time points after particle injection. An automated computer program was used to quantify the grey scale changes. Ultrasonic reflections were observed from nanoparticle suspensions in agarose gels. The image brightness, i.e., mean grey scale level, increased with particle size and concentration. The mean grey scale of mouse livers also increased following particle administration. These results indicated that it is feasible to use solid nanoparticles as contrast enhancing agents for ultrasonic imagin000.

  19. Theoretical considerations in measurement of time discrepancies between input and myocardial time-signal intensity curves in estimates of regional myocardial perfusion with first-pass contrast-enhanced MRI.

    Science.gov (United States)

    Natsume, Takahiro; Ishida, Masaki; Kitagawa, Kakuya; Nagata, Motonori; Sakuma, Hajime; Ichihara, Takashi

    2015-11-01

    The purpose of this study was to develop a method to determine time discrepancies between input and myocardial time-signal intensity (TSI) curves for accurate estimation of myocardial perfusion with first-pass contrast-enhanced MRI. Estimation of myocardial perfusion with contrast-enhanced MRI using kinetic models requires faithful recording of contrast content in the blood and myocardium. Typically, the arterial input function (AIF) is obtained by setting a region of interest in the left ventricular cavity. However, there is a small delay between the AIF and the myocardial curves, and such time discrepancies can lead to errors in flow estimation using Patlak plot analysis. In this study, the time discrepancies between the arterial TSI curve and the myocardial tissue TSI curve were estimated based on the compartment model. In the early phase after the arrival of the contrast agent in the myocardium, the relationship between rate constant K1 and the concentrations of Gd-DTPA contrast agent in the myocardium and arterial blood (LV blood) can be described by the equation K1={dCmyo(tpeak)/dt}/Ca(tpeak), where Cmyo(t) and Ca(t) are the relative concentrations of Gd-DTPA contrast agent in the myocardium and in the LV blood, respectively, and tpeak is the time corresponding to the peak of Ca(t). In the ideal case, the time corresponding to the maximum upslope of Cmyo(t), tmax, is equal to tpeak. In practice, however, there is a small difference in the arrival times of the contrast agent into the LV and into the myocardium. This difference was estimated to correspond to the difference between tpeak and tmax. The magnitudes of such time discrepancies and the effectiveness of the correction for these time discrepancies were measured in 18 subjects who underwent myocardial perfusion MRI under rest and stress conditions. The effects of the time discrepancies could be corrected effectively in the myocardial perfusion estimates. Copyright © 2015 Elsevier Inc. All rights

  20. Real-time observations of mechanical stimulus-induced enhancements of mechanical properties in osteoblast cells

    International Nuclear Information System (INIS)

    Zhang Xu; Liu Xiaoli; Sun Jialun; He Shuojie; Lee, Imshik; Pak, Hyuk Kyu

    2008-01-01

    Osteoblast, playing a key role in the pathophysiology of osteoporosis, is one of the mechanical stress sensitive cells. The effects of mechanical load-induced changes of mechanical properties in osteoblast cells were studied at real-time. Osteoblasts obtained from young Wister rats were exposed to mechanical loads in different frequencies and resting intervals generated by atomic force microscopy (AFM) probe tip and simultaneously measured the changes of the mechanical properties by AFM. The enhancement of the mechanical properties was observed and quantified by the increment of the apparent Young's modulus, E * . The observed mechanical property depended on the frequency of applied tapping loads. For the resting interval is 50 s, the mechanical load-induced enhancement of E * -values disappears. It seems that the enhanced mechanical property was recover able under no additional mechanical stimulus

  1. Effect of duration of contrast material injection on peak enhancement times and values of the aorta, main portal vein, and liver at dynamic MDCT with the dose of contrast medium tailored to patient weight

    International Nuclear Information System (INIS)

    Erturk, S.M.; Ichikawa, T.; Sou, H.; Tsukamoto, T.; Motosugi, U.; Araki, T.

    2008-01-01

    Aim: To investigate the effects of contrast material injection duration on peak enhancement times and attenuation values of the aorta, main portal vein, and liver at MDCT when the dose of contrast material is adjusted to patient weight. Material and methods: Seventy-five patients were randomly assigned to one of five groups, with durations of injection of 25, 30, 35, 40, or 45 s. All patients were injected with 2 ml/kg iodine (300 mg/ml). Attenuation values and peak enhancement times for the aorta, main portal vein, and liver were determined. The relationship between patient weight and enhancement times and values, the differences regarding peak enhancement times, and the relationship between injection duration and enhancement values were investigated using Pearson correlation, analysis of variance (ANOVA), and Spearman rank correlation, respectively. Results: No significant correlations were seen between patient weight and peak enhancement times or values. Mean peak enhancement times for the aorta, main portal vein, and liver were 9-11 s, 18-22 s, and 30-34 s, respectively (p > 0.05). The correlations between injection duration and peak enhancement values were significant and negative. Conclusions: Regardless of patient weight and injection duration, peak enhancement times of aorta, main portal vein and liver were approximately 10, 20, and 30 s, respectively. The enhancement values tended to be higher for shorter injection durations

  2. Vascularization of liver tumors - preliminary results with Coded Harmonic Angio (CHA), phase inversion imaging, 3D power Doppler and contrast medium-enhanced B-flow with second generation contrast agent (Optison).

    Science.gov (United States)

    Jung, E M; Kubale, R; Jungius, K-P; Jung, W; Lenhart, M; Clevert, D-A

    2006-01-01

    To investigate the dynamic value of contrast medium-enhanced ultrasonography with Optison for appraisal of the vascularization of hepatic tumors using harmonic imaging, 3D-/power Doppler and B-flow. 60 patients with a mean age of 56 years (range 35-76 years) with 93 liver tumors, including histopathologically proven hepatocellular carcinoma (HCC) [15 cases with 20 lesions], liver metastases of colorectal tumors [17 cases with 33 lesions], metastases of breast cancer [10 cases with 21 lesions] and hemangiomas [10 cases with 19 lesions] were prospectively investigated by means of multislice CT as well as native and contrast medium-enhanced ultrasound using a multifrequency transducer (2.5-4 MHz, Logig 9, GE). B scan was performed with additional color and power Doppler, followed by a bolus injection of 0.5 ml Optison. Tumor vascularization was evaluated with coded harmonic angio (CHA), pulse inversion imaging with power Doppler, 3D power Doppler and in the late phase (>5 min) with B-flow. In 15 cases with HCC, i.a. DSA was performed in addition. The results were also correlated with MRT and histological findings. Compared to spiral-CT/MRT, only 72/93 (77%) of the lesions could be detected in the B scan, 75/93 (81%) with CHA and 93/93 (100%) in the pulse inversion mode. Tumor vascularization was detectable in 43/93 (46%) of lesions with native power Doppler, in 75/93 (81%) of lesions after administering contrast medium in the CHA mode, in 81/93 (87%) of lesions in the pulse inversion mode with power Doppler and in 77/93 (83%) of lesions with contrast-enhanced B-flow. Early arterial and capillary perfusion was best detected with CHA, particularly in 20/20 (100%) of the HCC lesions, allowing a 3D reconstruction. 3D power Doppler was especially useful in investigating the tumor margins. Up to 20 min after contrast medium injection, B-flow was capable of detecting increased metastatic tumor vascularization in 42/54 (78%) of cases and intratumoral perfusion in 17/20 (85

  3. Contrast enhancement CT by iopamidol

    International Nuclear Information System (INIS)

    Mori, Masaki; Makita, Nobue; Yanai, Kyoko

    1984-01-01

    In order to evaluate the contrast enhancement effect and safety of iopamidol (IOP) in CT examination, IOP was compared with angiographin (AG). In the liver and abdominal aorta, peak CT values were obtained earlier and were higher in the group with AG than in the group with IOP. However, CT values in the group with IOP decreased a little more slowly than those in the group with AG. There was no significant difference in the effect on contrast enhancement between the groups. Intravenous injection of IOP caused lower degree of burning sensation than that of AG, and some of the patients with IOP did not feel burning sensation at all. Changes in clinical laboratory values were slight before and after intravenous injection of IOP. These results suggest that IOP is satisfactory in terms of safety and effect on contrast enhancement in CT examination. (Namekawa, K.)

  4. Ultrasonography of the equine shoulder: technique and normal appearance.

    Science.gov (United States)

    Tnibar, M A; Auer, J A; Bakkali, S

    1999-01-01

    This study was intended to document normal ultrasonographic appearance of the equine shoulder and anatomic landmarks useful in clinical imaging. Both forelimbs of five equine cadavers and both forelimbs of six live adult horses were used. To facilitate understanding of the images, a zoning system assigned to the biceps brachii and to the infraspinatus tendon was developed. Ultrasonography was performed with a real-time B-mode semiportable sector scanner using 7.5- and 5-MHz transducers. On one cadaver limb, magnetic resonance imaging (MRI) was performed using a system at 1.5 Tesla, T1-weighted spin-echo sequence. Ultrasonography images were compared to frozen specimens and MRI images to correlate the ultrasonographic findings to the gross anatomy of the shoulder. Ultrasonography allowed easy evaluation of the biceps brachii and the infraspinatus tendon and their bursae, the supraspinatus muscle and tendons, the superficial muscles of the shoulder, and the underlying humerus and scapula. Only the lateral and, partially, the caudal aspects of the humeral head could be visualized with ultrasound. Ultrasonographic appearance, orientation, and anatomic relationships of these structures are described. Ultrasonographic findings correlated well with MRI images and with gross anatomy in the cadavers' limbs.

  5. Visualization of endolymphatic hydrops in meniere's disease after single-dose intravenous gadolinium-based contrast medium. Timing of optimal enhancement

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Yamazaki, Masahiro; Kawai, Hisashi; Bokura, Kiminori; Sone, Michihiko; Nakashima, Tsutomu

    2012-01-01

    Visualization of endolymphatic hydrops (EH) in patients with Meniere's disease (MD) is now possible by heavily T 2 -weighted 3-dimensional fluid-attenuated inversion recovery (h T 2 W-3D-FLAIR) obtained 4 hours after intravenous (IV) administration of single dose gadolinium-based contrast medium (GBCM). Although maximum enhancement has been reported 4 hours after contrast administration in healthy volunteers, the timing of optimal enhancement in patients with MD is not reported. We investigated if that optimal timing is earlier or later than 4 hours. We evaluated 10 consecutive patients with suspected MD whom we randomly divided into 2 groups. We obtained h T 2 W-3D-FLAIR before GBCM administration and 10 min, 3.5 hours, and 4 hours after GBCM administration in Group A and before and 10 min, 4 hours, and 4.5 hours after GBCM administration in Group B. We compared signal intensity ratio (SIR) values of the perilymph and pons between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B and evaluated grades of EH at 3.5 and 4 hours in Group A and at 4 and 4.5 hours in Group B. SIR values did not differ significantly between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B. However, SIR values at 4 hours were significantly higher in Group A than Group B. Grades of EH agreed between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B. The optimal timing of contrast enhancement in patients with suspected MD remains unclear, but evaluation of EH may be possible from 3.5 to 4.5 hours after contrast administration. (author)

  6. Enhanced conjugation stability and blood circulation time of macromolecular gadolinium-DTPA contrast agent.

    Science.gov (United States)

    Jenjob, Ratchapol; Kun, Na; Ghee, Jung Yeon; Shen, Zheyu; Wu, Xiaoxia; Cho, Steve K; Lee, Don Haeng; Yang, Su-Geun

    2016-04-01

    In this study, we prepared macromolecular MR T1 contrast agent: pullulan-conjugated Gd diethylene triamine pentaacetate (Gd-DTPA-Pullulan) and estimated residual free Gd(3+), chelation stability in competition with metal ions, plasma and tissue pharmacokinetics, and abdominal MR contrast on rats. Residual free Gd(3+) in Gd-DTPA-Pullulan was measured using colorimetric spectroscopy. The transmetalation of Gd(3+) incubated with Ca(2+) was performed by using a dialysis membrane (MWCO 100-500 Da) and investigated by ICP-OES. The plasma concentration profiles of Gd-DTPA-Pullulan were estimated after intravenous injection at a dose 0.1 mmol/kg of Gd. The coronal-plane abdominal images of normal rats were observed by MR imaging. The content of free Gd(3+), the toxic residual form, was less than 0.01%. Chelation stability of Gd-DTPA-Pullulan was estimated, and only 0.2% and 0.00045% of Gd(3+) were released from Gd-DTPA-Pullulan after 2h incubation with Ca(2+) and Fe(2+), respectively. Gd-DTPA-Pullulan displayed the extended plasma half-life (t1/2,α=0.43 h, t1/2,β=2.32 h), much longer than 0.11h and 0.79 h of Gd-EOB-DTPA. Abdominal MR imaging showed Gd-DTPA-Pullulan maintained initial MR contrast for 30 min. The extended plasma half-life of Gd-DTPA-Pullulan probably allows the prolonged MR acquisition time in clinic with enhanced MR contrast. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Real-time systems

    OpenAIRE

    Badr, Salah M.; Bruztman, Donald P.; Nelson, Michael L.; Byrnes, Ronald Benton

    1992-01-01

    This paper presents an introduction to the basic issues involved in real-time systems. Both real-time operating sys and real-time programming languages are explored. Concurrent programming and process synchronization and communication are also discussed. The real-time requirements of the Naval Postgraduate School Autonomous Under Vehicle (AUV) are then examined. Autonomous underwater vehicle (AUV), hard real-time system, real-time operating system, real-time programming language, real-time sy...

  8. Experiment Design Regularization-Based Hardware/Software Codesign for Real-Time Enhanced Imaging in Uncertain Remote Sensing Environment

    Directory of Open Access Journals (Sweden)

    Castillo Atoche A

    2010-01-01

    Full Text Available A new aggregated Hardware/Software (HW/SW codesign approach to optimization of the digital signal processing techniques for enhanced imaging with real-world uncertain remote sensing (RS data based on the concept of descriptive experiment design regularization (DEDR is addressed. We consider the applications of the developed approach to typical single-look synthetic aperture radar (SAR imaging systems operating in the real-world uncertain RS scenarios. The software design is aimed at the algorithmic-level decrease of the computational load of the large-scale SAR image enhancement tasks. The innovative algorithmic idea is to incorporate into the DEDR-optimized fixed-point iterative reconstruction/enhancement procedure the convex convergence enforcement regularization via constructing the proper multilevel projections onto convex sets (POCS in the solution domain. The hardware design is performed via systolic array computing based on a Xilinx Field Programmable Gate Array (FPGA XC4VSX35-10ff668 and is aimed at implementing the unified DEDR-POCS image enhancement/reconstruction procedures in a computationally efficient multi-level parallel fashion that meets the (near real-time image processing requirements. Finally, we comment on the simulation results indicative of the significantly increased performance efficiency both in resolution enhancement and in computational complexity reduction metrics gained with the proposed aggregated HW/SW co-design approach.

  9. A hardware architecture for real-time shadow removal in high-contrast video

    Science.gov (United States)

    Verdugo, Pablo; Pezoa, Jorge E.; Figueroa, Miguel

    2017-09-01

    Broadcasting an outdoor sports event at daytime is a challenging task due to the high contrast that exists between areas in the shadow and light conditions within the same scene. Commercial cameras typically do not handle the high dynamic range of such scenes in a proper manner, resulting in broadcast streams with very little shadow detail. We propose a hardware architecture for real-time shadow removal in high-resolution video, which reduces the shadow effect and simultaneously improves shadow details. The algorithm operates only on the shadow portions of each video frame, thus improving the results and producing more realistic images than algorithms that operate on the entire frame, such as simplified Retinex and histogram shifting. The architecture receives an input in the RGB color space, transforms it into the YIQ space, and uses color information from both spaces to produce a mask of the shadow areas present in the image. The mask is then filtered using a connected components algorithm to eliminate false positives and negatives. The hardware uses pixel information at the edges of the mask to estimate the illumination ratio between light and shadow in the image, which is then used to correct the shadow area. Our prototype implementation simultaneously processes up to 7 video streams of 1920×1080 pixels at 60 frames per second on a Xilinx Kintex-7 XC7K325T FPGA.

  10. Real-Time Transportation Mode Identification Using Artificial Neural Networks Enhanced with Mode Availability Layers: A Case Study in Dubai

    Directory of Open Access Journals (Sweden)

    Young-Ji Byon

    2017-09-01

    Full Text Available Traditionally, departments of transportation (DOTs have dispatched probe vehicles with dedicated vehicles and drivers for monitoring traffic conditions. Emerging assisted GPS (AGPS and accelerometer-equipped smartphones offer new sources of raw data that arise from voluntarily-traveling smartphone users provided that their modes of transportation can correctly be identified. By introducing additional raster map layers that indicate the availability of each mode, it is possible to enhance the accuracy of mode detection results. Even in its simplest form, an artificial neural network (ANN excels at pattern recognition with a relatively short processing timeframe once it is properly trained, which is suitable for real-time mode identification purposes. Dubai is one of the major cities in the Middle East and offers unique environments, such as a high density of extremely high-rise buildings that may introduce multi-path errors with GPS signals. This paper develops real-time mode identification ANNs enhanced with proposed mode availability geographic information system (GIS layers, firstly for a universal mode detection and, secondly for an auto mode detection for the particular intelligent transportation system (ITS application of traffic monitoring, and compares the results with existing approaches. It is found that ANN-based real-time mode identification, enhanced by mode availability GIS layers, significantly outperforms the existing methods.

  11. Real-time video quality monitoring

    Science.gov (United States)

    Liu, Tao; Narvekar, Niranjan; Wang, Beibei; Ding, Ran; Zou, Dekun; Cash, Glenn; Bhagavathy, Sitaram; Bloom, Jeffrey

    2011-12-01

    The ITU-T Recommendation G.1070 is a standardized opinion model for video telephony applications that uses video bitrate, frame rate, and packet-loss rate to measure the video quality. However, this model was original designed as an offline quality planning tool. It cannot be directly used for quality monitoring since the above three input parameters are not readily available within a network or at the decoder. And there is a great room for the performance improvement of this quality metric. In this article, we present a real-time video quality monitoring solution based on this Recommendation. We first propose a scheme to efficiently estimate the three parameters from video bitstreams, so that it can be used as a real-time video quality monitoring tool. Furthermore, an enhanced algorithm based on the G.1070 model that provides more accurate quality prediction is proposed. Finally, to use this metric in real-world applications, we present an example emerging application of real-time quality measurement to the management of transmitted videos, especially those delivered to mobile devices.

  12. Non-contrast enhanced magnetic resonance angiography techniques in candidates for kidney transplantation: A comparative study

    International Nuclear Information System (INIS)

    Blankholm, Anne Dorte; Ginnerup-Pedersen, Bodil; Stausbøl-Grøn, Brian; Haislund, Margit; Laustsen, Sussie; Ringgaard, Steffen

    2013-01-01

    Aim: Detailed knowledge of vessel status in potential candidates for kidney transplantation is essential for the surgeon. Contrast enhanced magnetic resonance angiography has previously been used intensively for assessing this, but the discovery that use of gadolinium based contrast agents in magnetic resonance imaging can cause Nephrogenic Systemic Fibrosis in patients suffering from severe kidney disease has lead to renewed interest in non-contrast enhanced magnetic resonance angiography. The aim of this study was to find a non-contrast enhanced magnetic resonance angiography method for preoperative evaluation of the pelvic vessels prior to kidney transplantation, providing a sufficient image quality. Method: In a prospective study we consecutively included 54 patients undergoing examinations prior to kidney transplantation. The patients were examined with the following magnetic resonance angiography sequences: A 2D Time of flight (n = 54), 3D Time of flight (n = 52) patients, 3D Phase Contrast (n = 54), 3D Balanced Steady State Free Precession (n = 52) and a 2D TRiggered Angiography Non-Contrast Enhanced (TRANCE) (a Spin Echo sequence with subtraction) (n = 48). The sequences were evaluated with respect to contrast, diagnostic performance and artefact burden. Results: Evaluating contrast, 3D Phase Contrast was significantly better than 2D Time of flight (p 0.2). The 2D Time of flight was significantly better than the other sequences (p < 0.001) in all cases. The artefact score was lowest for the Phase Contrast images and significantly superior to the 2D Time of flight (p < 0.005). The 2D Time of flight was significantly better than the three other sequences (p < 0.001) in all cases. Conclusion: Non-contrast enhanced magnetic resonance angiography offers a safe preoperative examination for assessment of vessel status before kidney transplantation. A combination of 2D Time of flight and 3D Phase Contrast acquisitions is recommended and can be performed within a

  13. Enhanced renal image contrast by ethanol fixation in phase-contrast X-ray computed tomography.

    Science.gov (United States)

    Shirai, Ryota; Kunii, Takuya; Yoneyama, Akio; Ooizumi, Takahito; Maruyama, Hiroko; Lwin, Thet Thet; Hyodo, Kazuyuki; Takeda, Tohoru

    2014-07-01

    Phase-contrast X-ray imaging using a crystal X-ray interferometer can depict the fine structures of biological objects without the use of a contrast agent. To obtain higher image contrast, fixation techniques have been examined with 100% ethanol and the commonly used 10% formalin, since ethanol causes increased density differences against background due to its physical properties and greater dehydration of soft tissue. Histological comparison was also performed. A phase-contrast X-ray system was used, fitted with a two-crystal X-ray interferometer at 35 keV X-ray energy. Fine structures, including cortex, tubules in the medulla, and the vessels of ethanol-fixed kidney could be visualized more clearly than that of formalin-fixed tissues. In the optical microscopic images, shrinkage of soft tissue and decreased luminal space were observed in ethanol-fixed kidney; and this change was significantly shown in the cortex and outer stripe of the outer medulla. The ethanol fixation technique enhances image contrast by approximately 2.7-3.2 times in the cortex and the outer stripe of the outer medulla; the effect of shrinkage and the physical effect of ethanol cause an increment of approximately 78% and 22%, respectively. Thus, the ethanol-fixation technique enables the image contrast to be enhanced in phase-contrast X-ray imaging.

  14. Differential diagnosis of gastric cancer and gastritis: the role of contrast-enhanced ultrasound (CEUS).

    Science.gov (United States)

    Xue, Heng; Ge, Hui-Yu; Miao, Li-Ying; Wang, Shu-Min; Zhao, Bo; Wang, Jin-Rui; Cui, Li-Gang

    2017-03-01

    To evaluate the diagnostic performance of contrast-enhanced ultrasound (CEUS) in differential diagnosis of gastric cancer and gastritis, with histological results as reference standard. From September 2011 to August 2014, 82 patients (50 males and 32 females; mean age ± SD, 59.5 ± 15.0 years; range 19-91 years) with gastric cancer or gastritis were included in this Ethics Committee-approved prospective study. Conventional ultrasonography (US) and CEUS were applied to distinguish the two lesions, and both qualitative and quantitative features were evaluated. Of the 82 histopathologic-proven lesions, 58 were cancer and 24 were gastritis. For US, the gastric wall stratification was not preserved in about one-third of cancer (21/58, 36.2%) compared with gastritis (0/24, 0%) (p gastritis (19/24, 79.2%, p gastritis. CEUS has the potential to make the diagnosis more accurate.

  15. Linux real-time framework for fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Neto, Andre [Associacao Euratom-IST, Instituto de Plasmas e Fusao Nuclear, Av. Rovisco Pais, 1049-001 Lisboa (Portugal)], E-mail: andre.neto@cfn.ist.utl.pt; Sartori, Filippo; Piccolo, Fabio [Euratom-UKAEA, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Barbalace, Antonio [Euratom-ENEA Association, Consorzio RFX, 35127 Padova (Italy); Vitelli, Riccardo [Dipartimento di Informatica, Sistemi e Produzione, Universita di Roma, Tor Vergata, Via del Politecnico 1-00133, Roma (Italy); Fernandes, Horacio [Associacao Euratom-IST, Instituto de Plasmas e Fusao Nuclear, Av. Rovisco Pais, 1049-001 Lisboa (Portugal)

    2009-06-15

    A new framework for the development and execution of real-time codes is currently being developed and commissioned at JET. The foundations of the system are Linux, the Real Time Application Interface (RTAI) and a wise exploitation of the new i386 multi-core processors technology. The driving motivation was the need to find a real-time operating system for the i386 platform able to satisfy JET Vertical Stabilisation Enhancement project requirements: 50 {mu}s cycle time. Even if the initial choice was the VxWorks operating system, it was decided to explore an open source alternative, mostly because of the costs involved in the commercial product. The work started with the definition of a precise set of requirements and milestones to achieve: Linux distribution and kernel versions to be used for the real-time operating system; complete characterization of the Linux/RTAI real-time capabilities; exploitation of the multi-core technology; implementation of all the required and missing features; commissioning of the system. Latency and jitter measurements were compared for Linux and RTAI in both user and kernel-space. The best results were attained using the RTAI kernel solution where the time to reschedule a real-time task after an external interrupt is of 2.35 {+-} 0.35 {mu}s. In order to run the real-time codes in the kernel-space, a solution to provide user-space functionalities to the kernel modules had to be designed. This novel work provided the most common functions from the standard C library and transparent interaction with files and sockets to the kernel real-time modules. Kernel C++ support was also tested, further developed and integrated in the framework. The work has produced very convincing results so far: complete isolation of the processors assigned to real-time from the Linux non real-time activities, high level of stability over several days of benchmarking operations and values well below 3 {mu}s for task rescheduling after external interrupt. From

  16. Linux real-time framework for fusion devices

    International Nuclear Information System (INIS)

    Neto, Andre; Sartori, Filippo; Piccolo, Fabio; Barbalace, Antonio; Vitelli, Riccardo; Fernandes, Horacio

    2009-01-01

    A new framework for the development and execution of real-time codes is currently being developed and commissioned at JET. The foundations of the system are Linux, the Real Time Application Interface (RTAI) and a wise exploitation of the new i386 multi-core processors technology. The driving motivation was the need to find a real-time operating system for the i386 platform able to satisfy JET Vertical Stabilisation Enhancement project requirements: 50 μs cycle time. Even if the initial choice was the VxWorks operating system, it was decided to explore an open source alternative, mostly because of the costs involved in the commercial product. The work started with the definition of a precise set of requirements and milestones to achieve: Linux distribution and kernel versions to be used for the real-time operating system; complete characterization of the Linux/RTAI real-time capabilities; exploitation of the multi-core technology; implementation of all the required and missing features; commissioning of the system. Latency and jitter measurements were compared for Linux and RTAI in both user and kernel-space. The best results were attained using the RTAI kernel solution where the time to reschedule a real-time task after an external interrupt is of 2.35 ± 0.35 μs. In order to run the real-time codes in the kernel-space, a solution to provide user-space functionalities to the kernel modules had to be designed. This novel work provided the most common functions from the standard C library and transparent interaction with files and sockets to the kernel real-time modules. Kernel C++ support was also tested, further developed and integrated in the framework. The work has produced very convincing results so far: complete isolation of the processors assigned to real-time from the Linux non real-time activities, high level of stability over several days of benchmarking operations and values well below 3 μs for task rescheduling after external interrupt. From being the

  17. Transvaginal ultrasonography in first trimester of pregnancy and its comparison with transabdominal ultrasonography

    Directory of Open Access Journals (Sweden)

    Aneet Kaur

    2011-01-01

    Full Text Available Objectives : Examination of pregnant women in the first trimester with transvaginal ultrasonography with the aim to study various fetal development markers, e.g., gestation sac, yolk sac, fetal heart motion, CRL length, and fetal anatomy in both normal and abnormal pregnancies. Comparative evaluation of transvaginal ultrasonography vis-ΰ-vis transabdominal scanning in the study of first trimester of pregnancy and its complications. To assess the relative merits and demerits of transvaginal ultrasonography in comparison with the transabdominal technique. Materials and Methods : The study will be conducted on 50 females patients during the first trimester of pregnancy. The study population will consist of both normal and abnormal pregnancies. These patients will be included on the basis of suspicion of or proven pregnancy of duration up to 12 weeks from LMP. The evaluation of the patients will include the following: Record of patients obstetrical history and clinical examination, record of pregnancy test and relevant investigations, ultrasonic examination of pregnancy. (a Transabdominal ultrasound scanning will be done with moderately distended bladder by using real time scanners with low frequency probe (3/3.5 MHz; (b transvaginal sonography will be done with the real-time sector scanner using high-frequency endovaginal probe (5/7.5 MHz, after the patient voids urine. Relevant images will be taken by using the multiformat automatic camera. Results and Conclusions : In the study of 46 normal intrauterine pregnancies, TVS showed additional information in 36 patients (78.3% as compared to TAS, in detection of gestation sac, yolk sac, double bleb sign, or better visualization of embryonic anatomy. In the abnormal pregnancy (n=17, TVS provided more information in 11 cases (64.9%, which included detection of embryonic demise, yolk sac, double bleb sign, or subchorionic hemorrhage. Regarding ectopic gestations (n=7, TVS gave additional information in 5

  18. Contrast timing in computed tomography: Effect of different contrast media concentrations on bolus geometry

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Jost, Gregor; Seidensticker, Peter; Kuhl, Christiane; Pietsch, Hubertus

    2012-01-01

    Objective: To assess the effect of low-osmolar, monomeric contrast media with different iodine concentrations on bolus shape in aortic CT angiography. Materials and methods: Repeated sequential computed tomography scanning of the descending aorta of eight beagle dogs (5 male, 12.7 ± 3.1 kg) was performed without table movement with a standardized CT scan protocol. Iopromide 300 (300 mg I/mL), iopromide 370 (370 mg I/mL) and iomeprol 400 (400 mg I/mL) were administered via a foreleg vein with an identical iodine delivery rate of 1.2 g I/s and a total iodine dose of 300 mg I/kg body weight. Time-enhancement curves were computed and analyzed. Results: Iopromide 300 showed the highest peak enhancement (445.2 ± 89.1 HU), steepest up-slope (104.2 ± 17.5 HU/s) and smallest full width at half maximum (FWHM; 5.8 ± 1.0 s). Peak enhancement, duration of FWHM, enhancement at FWHM and up-slope differed significantly between iopromide 300 and iomeprol 400 (p 0.05). Conclusions: Low viscous iopromide 300 results in a better defined bolus with a significantly higher peak enhancement, steeper up-slope and smaller FWHM when compared to iomeprol 400. These characteristics potentially affect contrast timing.

  19. Contrast-enhanced time-resolved 3-D MRA: applications in neurosurgery and interventional neuroradiology

    International Nuclear Information System (INIS)

    Reinacher, Peter C.; Stracke, Paul; Reinges, Marcus H.T.; Hans, Franz J.; Krings, Timo

    2007-01-01

    The decision-making process in the endovascular treatment of cranial dural AV fistulas and angiomas and their follow-up after treatment is usually based on conventional digital subtraction angiography (DSA). Likewise, acquiring the vascular and hemodynamic information needed for presurgical evaluation of meningiomas may necessitate DSA or different MR-based angiographic methods to assess the arterial displacement, the location of bridging veins and tumor feeders, and the degree of vascularization. New techniques of contrast-enhanced MR angiography (MRA) permit the acquisition of images with high temporal and spatial resolution. The purpose of this study was to evaluate the applicability and clinical use of a newly developed contrast-enhanced 3-D dynamic MRA protocol for neurointerventional and neurosurgical planning and decision making. With a 3-T whole-body scanner (Philips Achieva), a 3-D dynamic contrast-enhanced (MultiHance, Bracco) MRA sequence with parallel imaging, and intelligent k-space readout (keyhole and ''CENTRA'' k-space filling) was added to structural MRI in patients with meningiomas, dural arteriovenous fistulas and pial arteriovenous malformations. The sequence had a temporal resolution of 1.3 s per 3-D volume with a spatial resolution of 0.566 x 0.566 x 1.5 mm per voxel in each 3-D volume and lasted 25.2 s. DSA was performed in selected patients following MRI. In patients with arteriovenous fistulas and malformations, MRA allowed the vascular shunt to be identified and correctly classified. Hemodynamic characteristics and venous architecture were clearly demonstrated. Larger feeding arteries could be identified in all patients. In meningiomas, MRA enabled assessment of the displacement of the cerebral arteries, depiction of the tumor feeding vessels, and evaluation of the anatomy of the venous system. The extent of tumor vascularization could be assessed in all patients and correlated with the histopathological findings that indicated

  20. Contrast-enhanced time-resolved 3-D MRA: applications in neurosurgery and interventional neuroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Reinacher, Peter C.; Stracke, Paul; Reinges, Marcus H.T.; Hans, Franz J.; Krings, Timo [University Hospital of the Technical University, Department of Neurosurgery, Aachen (Germany)

    2007-07-15

    The decision-making process in the endovascular treatment of cranial dural AV fistulas and angiomas and their follow-up after treatment is usually based on conventional digital subtraction angiography (DSA). Likewise, acquiring the vascular and hemodynamic information needed for presurgical evaluation of meningiomas may necessitate DSA or different MR-based angiographic methods to assess the arterial displacement, the location of bridging veins and tumor feeders, and the degree of vascularization. New techniques of contrast-enhanced MR angiography (MRA) permit the acquisition of images with high temporal and spatial resolution. The purpose of this study was to evaluate the applicability and clinical use of a newly developed contrast-enhanced 3-D dynamic MRA protocol for neurointerventional and neurosurgical planning and decision making. With a 3-T whole-body scanner (Philips Achieva), a 3-D dynamic contrast-enhanced (MultiHance, Bracco) MRA sequence with parallel imaging, and intelligent k-space readout (keyhole and ''CENTRA'' k-space filling) was added to structural MRI in patients with meningiomas, dural arteriovenous fistulas and pial arteriovenous malformations. The sequence had a temporal resolution of 1.3 s per 3-D volume with a spatial resolution of 0.566 x 0.566 x 1.5 mm per voxel in each 3-D volume and lasted 25.2 s. DSA was performed in selected patients following MRI. In patients with arteriovenous fistulas and malformations, MRA allowed the vascular shunt to be identified and correctly classified. Hemodynamic characteristics and venous architecture were clearly demonstrated. Larger feeding arteries could be identified in all patients. In meningiomas, MRA enabled assessment of the displacement of the cerebral arteries, depiction of the tumor feeding vessels, and evaluation of the anatomy of the venous system. The extent of tumor vascularization could be assessed in all patients and correlated with the histopathological findings that

  1. New endoscopic ultrasonography techniques for pancreticobiliary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kamata, Ken; Kitano, Masayuki; Omoto, Shunsuke; Kadosaka, Kumpei; Miyata, Takeshi; Minaga, Kosuke; Yamao, Kentaro; Imai, Hajime; Kudo, Masatoshii [Dept. of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka (Japan)

    2016-07-15

    Endoscopic ultrasonography (EUS) is widely used to evaluate pancreaticobiliary diseases, especially pancreatic masses. EUS has a good ability to detect pancreatic masses, but it is not sufficient for the differential diagnosis of various types of lesions. In order to address the limitations of EUS, new techniques have been developed to improve the characterization of the lesions detected by EUS. EUS-guided fine needle aspiration (EUS-FNA) has been used for diagnosing pancreatic tumors. In order to improve the histological diagnostic yield, a EUS-FNA needle with a core trap has recently been developed. Contrast-enhanced harmonic EUS is a new imaging modality that uses an ultrasonographic contrast agent to visualize blood flow in fine vessels. This technique is useful in the diagnosis of pancreatic solid lesions and in confirming the presence of vascularity in mural nodules for cystic lesions. EUS elastography analyzes several different variables to measure tissue elasticity, color patterns, and strain ratio, using analytical techniques such as hue-histogram analysis, and artificial neural networks, which are useful for the diagnosis of chronic pancreatitis and pancreatic cancer.

  2. Collateral configuration of the circle of Willis: transcranial color-coded duplex ultrasonography and comparison with postmortem anatomy

    NARCIS (Netherlands)

    Hoksbergen, A. W.; Fülesdi, B.; Legemate, D. A.; Csiba, L.

    2000-01-01

    BACKGROUND AND PURPOSE: The anterior communicating artery (AcoA) and posterior communicating arteries (PcoA) of the circle of Willis provide the main route for collateral blood flow in cases of carotid artery obstruction. Transcranial color-coded duplex ultrasonography (TCCD) allows real-time

  3. Pulmonary CT angiography: optimization of contrast enhancement technique

    International Nuclear Information System (INIS)

    Ma Lianju; Tang Guangjian; Fu Jiazhen

    2012-01-01

    Objective: To derive and evaluate the formula of exactly calculating the contrast dosage used during pulmonary CT angiography (CTPA). Methods: Time density curves in 27 patients who underwent CTPA were collected and analyzed,the formula for calculating contrast dosage during CTPA was derived. 68 patients suspected of pulmonary embolism (PE) clinically but no PE on CTPA were divided randomly into group A, with bolus tracing technique (n=26), and group B, with small dose injection contrast test (SDCT) (n=42). The CT values of the right main pulmonary artery (RMPA), right upper pulmonary vein (RUPV), right posterior basal PA, right lower PV (RLPV) and the aorta were calculated. The total contrast dosage and the hard beam artifact in the SVC were compared between the two groups.Student's t test, Chi-square test and Mann-Whitney U test were used. Results: The ratio of the time from starting injection to enhancement peak of caudal end of SVC and the time to enhancement peak of the main pulmonary trunk was 0.65 ±0.09 (about 2/3), the formula for contrast dosage calculation was derived as (DTs/3 + STs/2) FR ml/s. The CT values of RMPA and RLPA between the two groups [(301 ±117), (329 ± 122) and (283 ±95), (277 ±98) HU respectively] were not significantly different (t=1.060, P=0.292; t=2.056, P=0.044), but the differences of CT values in the paired PA and PV between the two groups (median were 22.5, 58.0 and 170.5, 166.5 HU respectively) were significant (U=292, P=0.001 and U=325, P=0.005), contrast artifact of the SVC (grade 1-3) in group B (n=34, 7, 1 respectively) was significantly less than in group A (n=11, 10, 5 respectively, χ 2 =10.714, P=0.002), the contrast dosage injected in group A was ( 87.6 ± 7.3) ml, and in group B was (40.0 ±5.4) ml (P<0.01). Conclusion: CTPA with SDCT technique is superior to that with conventional bolus tracing technique regarding contrast dosage and contrast artifact in the SVC. (authors)

  4. Neuromorphic infrared focal plane performs sensor fusion on-plane local-contrast-enhancement spatial and temporal filtering

    Science.gov (United States)

    Massie, Mark A.; Woolaway, James T., II; Curzan, Jon P.; McCarley, Paul L.

    1993-08-01

    An infrared focal plane has been simulated, designed and fabricated which mimics the form and function of the vertebrate retina. The `Neuromorphic' focal plane has the capability of performing pixel-based sensor fusion and real-time local contrast enhancement, much like the response of the human eye. The device makes use of an indium antimonide detector array with a 3 - 5 micrometers spectral response, and a switched capacitor resistive network to compute a real-time 2D spatial average. This device permits the summation of other sensor outputs to be combined on-chip with the infrared detections of the focal plane itself. The resulting real-time analog processed information thus represents the combined information of many sensors with the advantage that analog spatial and temporal signal processing is performed at the focal plane. A Gaussian subtraction method is used to produce the pixel output which when displayed produces an image with enhanced edges, representing spatial and temporal derivatives in the scene. The spatial and temporal responses of the device are tunable during operation, permitting the operator to `peak up' the response of the array to spatial and temporally varying signals. Such an array adapts to ambient illumination conditions without loss of detection performance. This paper reviews the Neuromorphic infrared focal plane from initial operational simulations to detailed design characteristics, and concludes with a presentation of preliminary operational data for the device as well as videotaped imagery.

  5. B-mode and contrast-enhanced sonographic assessment of accessory spleen in the dog.

    Science.gov (United States)

    Rossi, Federica; Rabba, Silvia; Vignoli, Massimo; Haers, Hendrik; Terragni, Rossella; Saunders, Jimmy H

    2010-01-01

    Four dogs with an accessory spleen are described. The accessory spleens appeared as a round-to-triangular structure located in the perisplenic area. They were homogeneous and isoechoic with the adjacent spleen. Contrast-enhanced ultrasound was performed using a second generation microbubble contrast medium (sulfur hexafluoride). The type and timing of enhancement of the accessory spleen was similar to that of the parent spleen. Contrast-enhanced ultrasound is a noninvasive modality useful in distinguishing an accessory spleen from a mass of another origin.

  6. Real-time thermal neutron radiographic detection systems

    International Nuclear Information System (INIS)

    Berger, H.; Bracher, D.A.

    1976-01-01

    Systems for real-time detection of thermal neutron images are reviewed. Characteristics of one system are presented; the data include contrast, resolution and speed of response over the thermal neutron intensity range 2.5 10 3 n/cm 2 -sec to 10 7 n/cm 2 -sec

  7. CONTRAST ENHANCED SPECTRAL MAMMOGRAPHY (CESM (REVIEW

    Directory of Open Access Journals (Sweden)

    N. I. Rozhkova

    2015-01-01

    Full Text Available The problem of early diagnosis of a breast cancer is extremely actual. Growth of incidence at women from 19 to 39 years increased for 34% over the last 10 years. It defines need of acceleration of development and deployment of the latest technologies of identification of the earliest symptoms of diseases. The x-ray mammography is the conducting method among of all radiological methods of diagnostics. Nevertheless a number of restrictions of method reduces its efficiency. The technologies increasing informational content of x-ray mammography – the leading method of screening – due to use of artificial contrasting and advantages of digital technologies are constantly developed. In this review it is described works, in which the authors having clinical experience of application of CESM – contrastenhanced spectral mammography on representative group of women. Positive sides and restrictions of new technology in comparison with mammography, ultrasonography and MRT are shown in this article.

  8. Contrast-enhanced angiographic cone-beam computed tomography without pre-diluted contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Jo, K.I.; Kim, S.R.; Choi, J.H.; Kim, K.H.; Jeon, P. [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Gangnam-gu, Seoul (Korea, Republic of)

    2015-11-15

    Contrast-enhanced cone-beam computed tomography (CBCT) has been introduced and accepted as a useful technique to evaluate delicate vascular anatomy and neurovascular stents. Current protocol for CBCT requires quantitative dilution of contrast medium to obtain adequate quality images. Here, we introduce simple methods to obtain contrast-enhanced CBCT without quantitative contrast dilution. A simple experiment was performed to estimate the change in flow rate in the internal carotid artery during the procedure. Transcranial doppler (TCD) was used to evaluate the velocity change before and after catheterization and fluid infusion. In addition, 0.3 cm{sup 3}/s (n = 3) and 0.2 cm{sup 3}/s (n = 7) contrast infusions were injected and followed by saline flushes using a 300 mmHg pressure bag to evaluate neurovascular stent and host arteries. Flow velocities changed -15 ± 6.8 % and +17 ± 5.5 % from baseline during catheterization and guiding catheter flushing with a 300 mmHg pressure bag, respectively. Evaluation of the stents and vascular structure was feasible using this technique in all patients. Quality assessment showed that the 0.2 cm{sup 3}/s contrast infusion protocol was better for evaluating the stent and host artery. Contrast-enhanced CBCT can be performed without quantitative contrast dilution. Adequate contrast dilution can be achieved with a small saline flush and normal blood flow. (orig.)

  9. Quantitative contrast-enhanced mammography for contrast medium kinetics studies

    Science.gov (United States)

    Arvanitis, C. D.; Speller, R.

    2009-10-01

    Quantitative contrast-enhanced mammography, based on a dual-energy approach, aims to extract quantitative and temporal information of the tumour enhancement after administration of iodinated vascular contrast media. Simulations using analytical expressions and optimization of critical parameters essential for the development of quantitative contrast-enhanced mammography are presented. The procedure has been experimentally evaluated using a tissue-equivalent phantom and an amorphous silicon active matrix flat panel imager. The x-ray beams were produced by a tungsten target tube and spectrally shaped using readily available materials. Measurement of iodine projected thickness in mg cm-2 has been performed. The effect of beam hardening does not introduce nonlinearities in the measurement of iodine projected thickness for values of thicknesses found in clinical investigations. However, scattered radiation introduces significant deviations from slope equal to unity when compared with the actual iodine projected thickness. Scatter correction before the analysis of the dual-energy images provides accurate iodine projected thickness measurements. At 10% of the exposure used in clinical mammography, signal-to-noise ratios in excess of 5 were achieved for iodine projected thicknesses less than 3 mg cm-2 within a 4 cm thick phantom. For the extraction of temporal information, a limited number of low-dose images were used with the phantom incorporating a flow of iodinated contrast medium. The results suggest that spatial and temporal information of iodinated contrast media can be used to indirectly measure the tumour microvessel density and determine its uptake and washout from breast tumours. The proposed method can significantly improve tumour detection in dense breasts. Its application to perform in situ x-ray biopsy and assessment of the oncolytic effect of anticancer agents is foreseeable.

  10. Contrast enhanced ultrasound in the evaluation and percutaneous treatment of hepatic and renal tumors

    International Nuclear Information System (INIS)

    Meloni, Maria Franca; Smolock, Amanda; Cantisani, Vito; Bezzi, Mario; D'Ambrosio, Ferdinando; Proiti, Maria; Lee, Fred; Aiani, Luca; Calliada, Fabrizio; Ferraioli, Giovanna

    2015-01-01

    Highlights: • Image-guided percutaneous ablation techniques are increasingly being used for the treatment of malignant tumors of the liver and kidney when surgery is not indicated. • Percutaneous ablation relies on imaging at every step of the process in order to detect, guide, and confirm complete tumor coagulation. • CEUS is a real-time dynamic imaging technique that plays an important role in the management of patients treated with ablation for malignant tumors. • This review focuses on the role of CEUS in the evaluation of patients undergoing percutaneous treatments for hepatic and renal tumors. - Abstract: Image-guided percutaneous ablation techniques are increasingly being used for the treatment of malignant tumors of the liver and kidney. Contrast enhanced ultrasound (CEUS) is a real-time dynamic imaging technique that plays an important role in the pre-, intra-, and post-procedural management of these patients. This review will focus on the role of CEUS in the evaluation of patients undergoing treatment with percutaneous ablation for hepatic or renal tumors

  11. Dynamic Contrast-Enhanced MRI of Cervical Cancers: Temporal Percentile Screening of Contrast Enhancement Identifies Parameters for Prediction of Chemoradioresistance

    International Nuclear Information System (INIS)

    Andersen, Erlend K.F.; Hole, Knut Håkon; Lund, Kjersti V.; Sundfør, Kolbein; Kristensen, Gunnar B.; Lyng, Heidi; Malinen, Eirik

    2012-01-01

    Purpose: To systematically screen the tumor contrast enhancement of locally advanced cervical cancers to assess the prognostic value of two descriptive parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Methods and Materials: This study included a prospectively collected cohort of 81 patients who underwent DCE-MRI with gadopentetate dimeglumine before chemoradiotherapy. The following descriptive DCE-MRI parameters were extracted voxel by voxel and presented as histograms for each time point in the dynamic series: normalized relative signal increase (nRSI) and normalized area under the curve (nAUC). The first to 100th percentiles of the histograms were included in a log-rank survival test, resulting in p value and relative risk maps of all percentile–time intervals for each DCE-MRI parameter. The maps were used to evaluate the robustness of the individual percentile–time pairs and to construct prognostic parameters. Clinical endpoints were locoregional control and progression-free survival. The study was approved by the institutional ethics committee. Results: The p value maps of nRSI and nAUC showed a large continuous region of percentile–time pairs that were significantly associated with locoregional control (p < 0.05). These parameters had prognostic impact independent of tumor stage, volume, and lymph node status on multivariate analysis. Only a small percentile–time interval of nRSI was associated with progression-free survival. Conclusions: The percentile–time screening identified DCE-MRI parameters that predict long-term locoregional control after chemoradiotherapy of cervical cancer.

  12. Angiogenesis and dynamic contrast enhanced MRI of benign and malignant breast lesions: preliminary results

    International Nuclear Information System (INIS)

    Liu Peifang; Bao Runxian; Niu Yun; Yu Yong

    2002-01-01

    Objective: To determine whether dynamic contrast enhanced MRI features of early-phase enhancement rate, enhancement amplitude, and signal intensity (SI) time course are associated with the microvessel density (MVD) and vascular endothelial growth factor (VEGF) expression of malignant and benign breast lesions. Methods: Thirty-eight patients with histopathologically verified breast lesions underwent dynamic contrast enhanced MRI. SI changes during dynamic scanning were assessed quantitatively. Early-phase enhancement rate and enhancement amplitude were calculated. Time-SI curves of the lesions were obtained and classified according to their shapes as type I (which was steady enhancement to the end of the dynamic data acquisition at 7.5 min), type II (plateau of SI after avid initial contrast enhancement), or type III (washout of SI after avid initial contrast enhancement). the mean MVD and VEGF expression of the lesions were measured with immuno-histochemical staining method in all the histologic specimens by pathologists without the knowledge of the results of the MR examination. The relationships among dynamic contrast enhanced MRI features, MVD, and VEGF expression of benign and malignant breast lesions were analyzed. Results: Histology revealed 21 malignancies and 17 benign lesions. The mean MVD and VEGF expression for 21 malignant lesions were statistically higher than the mean MVD and VEGF expression for 17 benign lesions. High VEGF expression of benign and malignant breast lesions showed an association with increased MVD. Among all 38 lesions, greater (> 60%) MR early-phase enhancement rate and time-SI curve type II and III showed an association with increased MVD and higher VEGF expression level. All the differences mentioned above showed statistical significance except that the difference between VEGF expression and the distribution of curve types had no statistical significance. No significant relationships were observed between the mean of enhancement

  13. Optimized enhancement in helical CT: Experiences with a real-time bolus tracking system in 628 patients

    International Nuclear Information System (INIS)

    Kirchner, J.; Kickuth, R.; Laufer, U.; Noack, M.; Liermann, D.

    2000-01-01

    AIMS: Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. MATERIALS AND METHODS: In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. RESULTS: There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). CONCLUSION: Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration. Kirchner, J. (2000). Clinical Radiology 55, 368-373

  14. Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients.

    Science.gov (United States)

    Kirchner, J; Kickuth, R; Laufer, U; Noack, M; Liermann, D

    2000-05-01

    Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration. Copyright 2000 The Royal College of Radiologists.

  15. A real-time prediction model for post-irradiation malignant cervical lymph nodes.

    Science.gov (United States)

    Lo, W-C; Cheng, P-W; Shueng, P-W; Hsieh, C-H; Chang, Y-L; Liao, L-J

    2018-04-01

    To establish a real-time predictive scoring model based on sonographic characteristics for identifying malignant cervical lymph nodes (LNs) in cancer patients after neck irradiation. One-hundred forty-four irradiation-treated patients underwent ultrasonography and ultrasound-guided fine-needle aspirations (USgFNAs), and the resultant data were used to construct a real-time and computerised predictive scoring model. This scoring system was further compared with our previously proposed prediction model. A predictive scoring model, 1.35 × (L axis) + 2.03 × (S axis) + 2.27 × (margin) + 1.48 × (echogenic hilum) + 3.7, was generated by stepwise multivariate logistic regression analysis. Neck LNs were considered to be malignant when the score was ≥ 7, corresponding to a sensitivity of 85.5%, specificity of 79.4%, positive predictive value (PPV) of 82.3%, negative predictive value (NPV) of 83.1%, and overall accuracy of 82.6%. When this new model and the original model were compared, the areas under the receiver operating characteristic curve (c-statistic) were 0.89 and 0.81, respectively (P real-time sonographic predictive scoring model was constructed to provide prompt and reliable guidance for USgFNA biopsies to manage cervical LNs after neck irradiation. © 2017 John Wiley & Sons Ltd.

  16. Contrast-enhanced ultrasonographic spoke-wheel sign in hepatic focal nodular hyperplasia

    International Nuclear Information System (INIS)

    Yen, Y.-H.; Wang, J.-H.; Lu, S.-N.; Chen, T.-Y.; Changchien, C.-S.; Chen, C.-H.; Hung, C.-H.; Lee, C.-M.

    2006-01-01

    Background: To determine the utility of contrast-enhanced ultrasonography (CEUS) in assessing hepatic tumors with central feeding arteries found by color/power Doppler ultrasonograophy (CDUS/PDUS). Methods: We prospectively studied 37 hepatic tumors (34 patients), with a mean size of 2.9 cm and each having a central feeding artery, by CDUS/PDUS. The CEUS was performed with a galactose-based microbubble contrast agent. The detection of a spoke-wheel sign was interpreted as evidence of focal nodular hyperplasia (FNH). All patients underwent tumor biopsies or surgical resection. Results: CEUS showed a central feeding artery with a spoke-wheel sign in 36 tumors, including 34 FNHs and 2 hepatocellular carcinomas. The remaining tumor was demonstrated to be FNH despite the absence of a spoke-wheel sign as detected by CEUS. The sensitivity of the spoke-wheel sign or central scar for FNH was 97.1% (34/35), 40% (14/35), 28.6% (10/35), 50% (8/16) and 0% (0/15) for CEUS, CDUS/PDUS, dynamic computed tomography (CT) or magnetic resonance imaging (MRI), hepatic angiography and liver scintigraphy, respectively. The two hepatocellular carcinomas showed scirrhous changes histologically. Conclusions: CEUS is more sensitive than CDUS/PDUS, dynamic CT, MRI, hepatic angiography and liver scintigraphy in the detection of the spoke-wheel sign or central scar in FNH. Scirrhous hepatocellular carcinoma should be included in the differential diagnosis for liver tumors with spoke-wheel sign detected by CEUS

  17. Contrast-enhanced ultrasonographic spoke-wheel sign in hepatic focal nodular hyperplasia

    Energy Technology Data Exchange (ETDEWEB)

    Yen, Y.-H. [Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, 123 Ta-Pei Road, Kaohsiung 833, Taiwan (China); Wang, J.-H. [Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, 123 Ta-Pei Road, Kaohsiung 833, Taiwan (China)]. E-mail: wajing@adm.cgmh.org.tw; Lu, S.-N. [Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, 123 Ta-Pei Road, Kaohsiung 833, Taiwan (China); Chen, T.-Y. [Department of Radiology, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung, College of Medicine, Chang Gung University, Taoyuan, Taiwan (China); Changchien, C.-S. [Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, 123 Ta-Pei Road, Kaohsiung 833, Taiwan (China); Chen, C.-H. [Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, 123 Ta-Pei Road, Kaohsiung 833, Taiwan (China); Hung, C.-H. [Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, 123 Ta-Pei Road, Kaohsiung 833, Taiwan (China); Lee, C.-M. [Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, 123 Ta-Pei Road, Kaohsiung 833, Taiwan (China)

    2006-12-15

    Background: To determine the utility of contrast-enhanced ultrasonography (CEUS) in assessing hepatic tumors with central feeding arteries found by color/power Doppler ultrasonograophy (CDUS/PDUS). Methods: We prospectively studied 37 hepatic tumors (34 patients), with a mean size of 2.9 cm and each having a central feeding artery, by CDUS/PDUS. The CEUS was performed with a galactose-based microbubble contrast agent. The detection of a spoke-wheel sign was interpreted as evidence of focal nodular hyperplasia (FNH). All patients underwent tumor biopsies or surgical resection. Results: CEUS showed a central feeding artery with a spoke-wheel sign in 36 tumors, including 34 FNHs and 2 hepatocellular carcinomas. The remaining tumor was demonstrated to be FNH despite the absence of a spoke-wheel sign as detected by CEUS. The sensitivity of the spoke-wheel sign or central scar for FNH was 97.1% (34/35), 40% (14/35), 28.6% (10/35), 50% (8/16) and 0% (0/15) for CEUS, CDUS/PDUS, dynamic computed tomography (CT) or magnetic resonance imaging (MRI), hepatic angiography and liver scintigraphy, respectively. The two hepatocellular carcinomas showed scirrhous changes histologically. Conclusions: CEUS is more sensitive than CDUS/PDUS, dynamic CT, MRI, hepatic angiography and liver scintigraphy in the detection of the spoke-wheel sign or central scar in FNH. Scirrhous hepatocellular carcinoma should be included in the differential diagnosis for liver tumors with spoke-wheel sign detected by CEUS.

  18. Diagnostic value of dynamic contrast-enhanced MRI for submucosal palatal tumors

    International Nuclear Information System (INIS)

    Matsuzaki, Hidenobu; Yanagi, Yoshinobu; Hara, Marina; Katase, Naoki; Hisatomi, Miki; Unetsubo, Teruhisa; Konouchi, Hironobu; Takenobu, Toshihiko

    2012-01-01

    Objectives: To evaluate the diagnostic value of dynamic contrast-enhanced MRI (DCE-MRI) for differentiating between benign and malignant tumors in the palate. Materials and methods: 26 patients with submucosal palatal tumors were preoperatively examined using DCE-MRI. Their maximum contrast index (CImax), time of CImax (Tmax), and washout ratios (WR300 and WR600) were determined from contrast index curves. The submucosal palatal tumors were divided into two groups according to their Tmax values: the early enhancement group (Tmax 2 = 0.92, P < 0.001). Conclusions: Tmax is a useful parameter for distinguishing between benign and malignant submucosal palatal tumors.

  19. Diagnostic Accuracy of Detecting Hashimoto's Thyroiditis in Thyroid Cancer Patients Who Underwent Thyroid Surgery: Comparison of Ultrasonography, Positron Emission Tomography/CT, Contrast Enhanced CT, and Anti-Thyroid Antibody

    International Nuclear Information System (INIS)

    Kim, Young Gyun; Lee, Tae Hyun; Park, Dong Hee; Nam, Sang Been

    2012-01-01

    To compare the diagnostic accuracy of ultrasonography (US), F18-fluorodeoxyglucose positron emission tomography/CT (PET/CT), contrast enhanced CT (CECT), serum anti-thyroid antibody for detecting Hashimoto's thyroiditis in thyroid cancer patients who underwent neck surgery. A total of 150 patients with suspicious for thyroid cancer, who had previously undergone US guided needle aspiration of thyroid, were evaluated with the use of US, PET/CT, CECT and serum anti-thyroid antibody. The four studies were performed within two months before neck surgery. Hashimoto's thyroiditis was confirmed by histopathological results. The diagnostic accuracy of US, PET/CT, CECT and serum anti-thyroid antibody were calculated statistically. Hashimoto's thyroiditis was diagnosed in 51 out of the 150 patients, following neck surgery. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of US were 76.5%, 92.9%, 84.8%, 88.5%, and 87.3%, respectively. The corresponding values of PET/CT were 37.3%, 96.0%, 82.6%, 74.8%, and 76.0%, and CECT were 62.7%, 89.9%, 76.2%, 82.4%, and 80.7%, and serum anti-thyroid antibody level were 90.2%, 93.9%, 88.5%, 94.9%, and 92.7%, respectively. McNemar test revealed significant difference among PET/CT and others, but no significant differences among US, CECT and serum anti-thyroid antibody. Overall, serum anti-thyroid antibody showed most accurate diagnostic performance. In detecting Hashimoto's thyroiditis, serum anti-thyroid antibody showed higher diagnostic accuracy than others. US also showed relatively high diagnostic accuracy.

  20. Visual Contrast Enhancement Algorithm Based on Histogram Equalization

    Science.gov (United States)

    Ting, Chih-Chung; Wu, Bing-Fei; Chung, Meng-Liang; Chiu, Chung-Cheng; Wu, Ya-Ching

    2015-01-01

    Image enhancement techniques primarily improve the contrast of an image to lend it a better appearance. One of the popular enhancement methods is histogram equalization (HE) because of its simplicity and effectiveness. However, it is rarely applied to consumer electronics products because it can cause excessive contrast enhancement and feature loss problems. These problems make the images processed by HE look unnatural and introduce unwanted artifacts in them. In this study, a visual contrast enhancement algorithm (VCEA) based on HE is proposed. VCEA considers the requirements of the human visual perception in order to address the drawbacks of HE. It effectively solves the excessive contrast enhancement problem by adjusting the spaces between two adjacent gray values of the HE histogram. In addition, VCEA reduces the effects of the feature loss problem by using the obtained spaces. Furthermore, VCEA enhances the detailed textures of an image to generate an enhanced image with better visual quality. Experimental results show that images obtained by applying VCEA have higher contrast and are more suited to human visual perception than those processed by HE and other HE-based methods. PMID:26184219

  1. Visual Contrast Enhancement Algorithm Based on Histogram Equalization

    Directory of Open Access Journals (Sweden)

    Chih-Chung Ting

    2015-07-01

    Full Text Available Image enhancement techniques primarily improve the contrast of an image to lend it a better appearance. One of the popular enhancement methods is histogram equalization (HE because of its simplicity and effectiveness. However, it is rarely applied to consumer electronics products because it can cause excessive contrast enhancement and feature loss problems. These problems make the images processed by HE look unnatural and introduce unwanted artifacts in them. In this study, a visual contrast enhancement algorithm (VCEA based on HE is proposed. VCEA considers the requirements of the human visual perception in order to address the drawbacks of HE. It effectively solves the excessive contrast enhancement problem by adjusting the spaces between two adjacent gray values of the HE histogram. In addition, VCEA reduces the effects of the feature loss problem by using the obtained spaces. Furthermore, VCEA enhances the detailed textures of an image to generate an enhanced image with better visual quality. Experimental results show that images obtained by applying VCEA have higher contrast and are more suited to human visual perception than those processed by HE and other HE-based methods.

  2. A Novel Contrast Enhancement Technique on Palm Bone Images

    Directory of Open Access Journals (Sweden)

    Yung-Tsang Chang

    2014-09-01

    Full Text Available Contrast enhancement plays a fundamental role in image processing. Many histogram-based techniques are widely used for contrast enhancement of given images, due to their simple function and effectiveness. However, the conventional histogram equalization (HE methods result in excessive contrast enhancement, which causes natural looking and satisfactory results for a variety of low contrast images. To solve such problems, a novel multi-histogram equalization technique is proposed to enhance the contrast of the palm bone X-ray radiographs in this paper. For images, the mean-variance analysis method is employed to partition the histogram of the original grey scale image into multiple sub-histograms. These histograms are independently equalized. By using this mean-variance partition method, a proposed multi-histogram equalization technique is employed to achieve the contrast enhancement of the palm bone X-ray radiographs. Experimental results show that the multi-histogram equalization technique achieves a lower average absolute mean brightness error (AMBE value. The multi-histogram equalization technique simultaneously preserved the mean brightness and enhanced the local contrast of the original image.

  3. Real-Time MRI Navigated Ultrasound for Preoperative Tumor Evaluation in Breast Cancer Patients: Technique and Clinical Implementation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ah Young; Seo, Bo Kyoung [Department of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan 15355 (Korea, Republic of)

    2016-11-01

    Real-time magnetic resonance imaging (MRI) navigated ultrasound is an image fusion technique to display the results of both MRI and ultrasonography on the same monitor. This system is a promising technique to improve lesion detection and analysis, to maximize advantages of each imaging modality, and to compensate the disadvantages of both MRI and ultrasound. In evaluating breast cancer stage preoperatively, MRI and ultrasound are the most representative imaging modalities. However, sometimes difficulties arise in interpreting and correlating the radiological features between these two different modalities. This pictorial essay demonstrates the technical principles of the real-time MRI navigated ultrasound, and clinical implementation of the system in preoperative evaluation of tumor extent, multiplicity, and nodal status in breast cancer patients.

  4. Real-time MRI navigated ultrasound for preoperative tumor evaluation in breast cancer patients: Technique and clinical implementation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ah Young; Seo, Bo Kyoung [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of)

    2016-09-15

    Real-time magnetic resonance imaging (MRI) navigated ultrasound is an image fusion technique to display the results of both MRI and ultrasonography on the same monitor. This system is a promising technique to improve lesion detection and analysis, to maximize advantages of each imaging modality, and to compensate the disadvantages of both MRI and ultrasound. In evaluating breast cancer stage preoperatively, MRI and ultrasound are the most representative imaging modalities. However, sometimes difficulties arise in interpreting and correlating the radiological features between these two different modalities. This pictorial essay demonstrates the technical principles of the real-time MRI navigated ultrasound, and clinical implementation of the system in preoperative evaluation of tumor extent, multiplicity, and nodal status in breast cancer patients.

  5. Contrast-enhanced breast MRI: factors affecting sensitivity and specificity

    Energy Technology Data Exchange (ETDEWEB)

    Piccoli, C.W. [Department of Radiology, Jefferson Medical College, Thomas Jefferson University Hospital, 132 South 10th Street, 7th floor, Philadelphia, PA 19107-5244 (United States)

    1997-12-31

    Contrast-enhanced MRI (CE-MRI) of the breast has been investigated for over 10 years. The reports of sensitivity for cancer detection have generally been greater than 90 %. However, estimates of specificity have varied greatly. Differing results are due to differences in study populations, technical methods and criteria for interpretation. Early and marked signal rise, detected using dynamic imaging technique following contrast administration, is the MRI hallmark of cancer. However, some malignant lesions may enhance slowly or minimally, and a variety of benign lesions may enhance rapidly with marked signal intensity. High resolution techniques generally requiring longer acquisition times are more likely to depict the slowly enhancing malignancies at the cost of a decrease in specificity due to lack of temporal resolution. This disadvantage may be offset by the improved visualization of lesion morphology with high resolution images. This report reviews the methods and results of the leading investigators of breast MRI. (orig.) With 3 figs., 70 refs.

  6. Contrast-enhanced breast MRI: factors affecting sensitivity and specificity

    International Nuclear Information System (INIS)

    Piccoli, C.W.

    1997-01-01

    Contrast-enhanced MRI (CE-MRI) of the breast has been investigated for over 10 years. The reports of sensitivity for cancer detection have generally been greater than 90 %. However, estimates of specificity have varied greatly. Differing results are due to differences in study populations, technical methods and criteria for interpretation. Early and marked signal rise, detected using dynamic imaging technique following contrast administration, is the MRI hallmark of cancer. However, some malignant lesions may enhance slowly or minimally, and a variety of benign lesions may enhance rapidly with marked signal intensity. High resolution techniques generally requiring longer acquisition times are more likely to depict the slowly enhancing malignancies at the cost of a decrease in specificity due to lack of temporal resolution. This disadvantage may be offset by the improved visualization of lesion morphology with high resolution images. This report reviews the methods and results of the leading investigators of breast MRI. (orig.)

  7. Dual-energy contrast-enhanced mammography.

    Science.gov (United States)

    Travieso Aja, M M; Rodríguez Rodríguez, M; Alayón Hernández, S; Vega Benítez, V; Luzardo, O P

    2014-01-01

    The degree of vascularization in breast lesions is related to their malignancy. For this reason, functional diagnostic imaging techniques have become important in recent years. Dual-energy contrast-enhanced mammography is a new, apparently promising technique in breast cancer that provides information about the degree of vascularization of the lesion in addition to the morphological information provided by conventional mammography. This article describes the state of the art for dual-energy contrast-enhanced mammography. Based on 15 months' clinical experience, we illustrate this review with clinical cases that allow us to discuss the advantages and limitations of this technique. Copyright © 2014 SERAM. Published by Elsevier Espana. All rights reserved.

  8. Dual-energy contrast-enhanced spectral mammography (CESM).

    Science.gov (United States)

    Daniaux, Martin; De Zordo, Tobias; Santner, Wolfram; Amort, Birgit; Koppelstätter, Florian; Jaschke, Werner; Dromain, Clarisse; Oberaigner, Willi; Hubalek, Michael; Marth, Christian

    2015-10-01

    Dual-energy contrast-enhanced mammography is one of the latest developments in breast care. Imaging with contrast agents in breast cancer was already known from previous magnetic resonance imaging and computed tomography studies. However, high costs, limited availability-or high radiation dose-led to the development of contrast-enhanced spectral mammography (CESM). We reviewed the current literature, present our experience, discuss the advantages and drawbacks of CESM and look at the future of this innovative technique.

  9. Morphological rational operator for contrast enhancement.

    Science.gov (United States)

    Peregrina-Barreto, Hayde; Herrera-Navarro, Ana M; Morales-Hernández, Luis A; Terol-Villalobos, Iván R

    2011-03-01

    Contrast enhancement is an important task in image processing that is commonly used as a preprocessing step to improve the images for other tasks such as segmentation. However, some methods for contrast improvement that work well in low-contrast regions affect good contrast regions as well. This occurs due to the fact that some elements may vanish. A method focused on images with different luminance conditions is introduced in the present work. The proposed method is based on morphological transformations by reconstruction and rational operations, which, altogether, allow a more accurate contrast enhancement resulting in regions that are in harmony with their environment. Furthermore, due to the properties of these morphological transformations, the creation of new elements on the image is avoided. The processing is carried out on luminance values in the u'v'Y color space, which avoids the creation of new colors. As a result of the previous considerations, the proposed method keeps the natural color appearance of the image.

  10. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is an x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  11. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is a x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  12. Contrast-enhanced power Doppler endosonography and pathological assessment of vascularization in advanced gastric carcinomas--a feasibility study.

    Science.gov (United States)

    Iordache, Sevastiţa; Filip, Maria-Monalisa; Georgescu, Claudia-Valentina; Angelescu, Cristina; Ciurea, Tudorel; Săftoiu, Adrian

    2012-06-01

    Besides representing angiogenesis markers, microvascular density (MVD) and vascular endothelial growth factor (VEGF) are two important tools for the assessment of prognosis in patients with gastric cancer. The aim of our study was to assess the Doppler parameters (resistivity and pulsatility indexes) and vascularity index (VI) calculated by contrast-enhanced power Doppler endoscopic ultrasound (CEPD-EUS) in correlation with the expression of intra-tumoral MVD and VEGF in patients with gastric cancer. The study included 20 consecutive patients with advanced gastric carcinoma, but without distant metastasis at initial assessment. All the patients were assessed by contrast-enhanced power Doppler endoscopic ultrasound (EUS) combined with pulsed Doppler examinations in the late venous phase. The vascularity index (VI) was calculated before and after injection of second generation microbubble contrast specific agent (SonoVue 2.4 mL), used as a Doppler signal enhancer. Moreover, pulsed Doppler parameters (resistivity and pulsatility indexes) were further calculated. The correlation between power Doppler parameters and pathological/molecular parameters (MVD assessed through immunohistochemistry with CD31 and CD34, as well as VEGF assessed through real-time PCR) was assessed. Kaplan-Meier survival analysis was used for the assessment of prognosis. Significantly statistical correlations were found between post-contrast VI and CD34 (p=0.0226), VEGF (p=0.0231), VEGF-A (p=0.0464) and VEGF-B (p=0.0022) while pre-contrast VI was correlated only with CD34 expression. Pulsatility index and resistivity index were not correlated with MVD or VEGF expression. Survival analysis demonstrated that VEGF-A is an accurate parameter for survival rate (p=0.045), as compared to VEGF (p=0.085) and VEGF-B (p=0.230). We did not find any correlation between the survival rate and ultrasound parameters (RI, PI, pre-contrast VI or post-contrast VI). Assessment of tumor vascularity using contrast-enhanced

  13. A clinical study concerning hepatic arterial dominant phase and arrival time of contrast media on helical dynamic CT

    International Nuclear Information System (INIS)

    Matsubara, Susumu; Uchida, Chiharu; Sato, Sei; Ishida, Junichi; Masuya, Ryozo; Makiguchi, Mako; Kanamori, Isao

    2001-01-01

    Hepatic arterial dominant phase in helical dynamic CT was optimized by measuring the arrival time of contrast media (ATCM) with time-density curve (TDC). Subjects were 1005 patients (577 males and 428 females) and 98 nodules diagnosed as advanced hepatocellular carcinoma (HCC). The CT was done with Toshiba 4MHU X-vision SP, ultrasonography with Toshiba SSH-160A and automatic infusion of the contrast medium, iopamidol or iohexol, with Nemotokyorindo Autoenhance A-50. ATCM was found correlated with pulse rate and with arterial diameter, and significantly different between the sex. Elevation slope of TDC was suggested to be made constant by a defined infusion time of the dose corrected by body weight. Fluctuation of TDC among patients , when normalized by ATCM, was found smaller and the TDC was suggested to be useful for better imaging of HCC of less than 10 mm diameter. (K.H.)

  14. The Future of Contrast-Enhanced Mammography.

    Science.gov (United States)

    Covington, Matthew F; Pizzitola, Victor J; Lorans, Roxanne; Pockaj, Barbara A; Northfelt, Donald W; Appleton, Catherine M; Patel, Bhavika K

    2018-02-01

    The purpose of this article is to discuss facilitators of and barriers to future implementation of contrast-enhanced mammography (CEM) in the United States. CEM provides low-energy 2D mammographic images analogous to digital mammography and contrast-enhanced recombined images that allow assessment of neovascularity similar to that offered by MRI. The utilization of CEM in the United States is currently low but could increase rapidly given the many potential indications for its clinical use.

  15. Real-time communication for distributed plasma control systems

    Energy Technology Data Exchange (ETDEWEB)

    Luchetta, A. [Consorzio RFX, Associazione Euratom-ENEA sulla Fusione, Corso Stati Uniti 4, Padova 35127 (Italy)], E-mail: adriano.luchetta@igi.cnr.it; Barbalace, A.; Manduchi, G.; Soppelsa, A.; Taliercio, C. [Consorzio RFX, Associazione Euratom-ENEA sulla Fusione, Corso Stati Uniti 4, Padova 35127 (Italy)

    2008-04-15

    Real-time control applications will benefit in the near future from the enhanced performance provided by multi-core processor architectures. Nevertheless real-time communication will continue to be critical in distributed plasma control systems where the plant under control typically is distributed over a wide area. At RFX-mod real-time communication is crucial for hard real-time plasma control, due to the distributed architecture of the system, which consists of several VMEbus stations. The system runs under VxWorks and uses Gigabit Ethernet for sub-millisecond real-time communication. To optimize communication in the system, a set of detailed measurements has been carried out on the target platforms (Motorola MVME5100 and MVME5500) using either the VxWorks User Datagram Protocol (UDP) stack or raw communication based on the data link layer. Measurements have been carried out also under Linux, using its UDP stack or, in alternative, RTnet, an open source hard real-time network protocol stack. RTnet runs under Xenomai or RTAI, two popular real-time extensions based on the Linux kernel. The paper reports on the measurements carried out and compares the results, showing that the performance obtained by using open source code is suitable for sub-millisecond real-time communication in plasma control.

  16. Contrast-enhanced voiding urosonography: in vitro evaluation of a second-generation ultrasound contrast agent for in vivo optimization.

    Science.gov (United States)

    Back, Susan J; Edgar, J Christopher; Canning, Douglas A; Darge, Kassa

    2015-09-01

    Pediatric contrast-enhanced ultrasound (CEUS) is primarily performed outside the United States where a track record for safety in intravenous and intravesical applications has been established. Contrast-enhanced voiding urosonography (ceVUS) has also been shown to have a much higher rate of vesicoureteral reflux detection compared to voiding cystourethrography. US contrast agents available in the United States differ from those abroad. Optison® (GE Healthcare, Princeton, NJ) is such an US contrast agent. While Optison® has similar characteristics to other second-generation agents, it has never been used for ceVUS. In vitro optimization of dose and imaging parameters as well as assessment of contrast visualization when delivered in conditions similar to ceVUS are necessary starting points prior to in vivo applications. To optimize the intravesical use of Optison® in vitro for ceVUS before its use in pediatric studies. The experimental design simulated intravesical use. Using 9- and 12-MHz linear transducers, we scanned 20-mL syringes varying mechanical index, US contrast agent concentration (0.25%, 0.5%, 1.0%), solvent (saline, urine, radiographic contrast agent) and time out of refrigeration. We evaluated mechanical index settings and contrast duration, optimized the contrast dose, measured the effect of urine and radiographic contrast agent, and the impact of length of time of contrast outside of the refrigerator on US contrast appearance. We scanned 50-ml saline bags to assess the appearance and duration of US contrast with different delivery systems (injection vs. infusion). Consistent contrast visualization was achieved at a mechanical index of 0.06-0.17 and 0.11-0.48 for the L9 and L12 MHz transducers (P contrast visualization of the microbubbles with a higher transducer frequency. The lowest mechanical index for earliest visible microbubble destruction was 0.21 for the 9 MHz and 0.39 for the 12 MHz (P contrast agent volume to bladder filling was the

  17. Fluorescence interference contrast based approach to study real time interaction of melittin with plasma membranes

    Science.gov (United States)

    Gupta, Sharad; Gui, Dong; Zandi, Roya; Gill, Sarjeet; Mohideen, Umar

    2014-03-01

    Melittin is an anti-bacterial and hemolytic toxic peptide found in bee venom. Cell lysis behavior of peptides has been widely investigated, but the exact interaction mechanism of lytic peptides with lipid membranes and its constituents has not been understood completely. In this paper we study the melittin interaction with lipid plasma membranes in real time using non-invasive and non-contact fluorescence interference contrast microscopy (FLIC). Particularly the interaction of melittin with plasma membranes was studied in a controlled molecular environment, where these plasma membrane were composed of saturated lipid, 1,2-diphytanoyl-sn-glycero-3-phosphocholine (DPhPC) and unsaturated lipid, 1,2-dioleoyl-sn-glycero-3-phosphocholine(DOPC) with and without cholesterol. We found out that melittin starts to form nanometer size pores in the plasma membranes shortly after interacting with membranes. But the addition of cholesterol in plasma membrane slows down the pore formation process. Our results show that inclusion of cholesterol to the plasma membranes make them more resilient towards pore formation and lysis of membrane.

  18. Contrast enhanced MR imaging of postoperative medulloblastoma in childhood: emphasis on meningeal enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Choong Gon; Kim, In One; Kim, Woo Sun; Kim, Ho Chul; Yeon, Kyung Mo [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1993-03-15

    To differentiate the postoperative changes from the recurrence of tumor and to evaluate MR imaging of early postoperative leptomeningeal seeding in medulloblastoma, We have retrospectively analysed 34 cases of MR images of 17 patients who were confirmed as medulloblastoma by histopathology. Noncontrast and postcontrast T1 weighted MR images were obtained in all patients. In 11 patients follow-up MR was done more than once (average: 1.5 times) and average interval of MR imaging was 6 months. The timing of 34 MR images was as follow: 6 case within 2 months, 9 cases between 2 months and 1 year, 19 cases more than 1 year after surgery respectively. MR images within 2 month after surgery revealed contrast enhancement at operation site and adjacent meninges, hemorrhage, residual tumor. In patients who had no evidence of tumor recurrence, these early postoperative changes were markedly decreased within 6 month after surgery. MR images obtained more than 1 year after surgery showed no abnormal contrast enhancement or mild focal dural enhancement at operation site. Diffuse moderate dural enhancement was noted in one patient who had the history of post-surgical subdural hemorrhage. In six patients with tumor recurrences which were detected from as early as 9 months to 6 years after surgery, the findings of recurrence included leptomeningeal enhancement of brain stem and cerebellar surface at early stage, variable sized enhancing leptomeningeal nodules, linear or irregular sulcus obliterating enhancing lesions, enhancing mass at primary or metastatic site. We have concluded that leptomeningeal enhancement detected after 6 months of surgery is an important MR finding suggesting the possibility of tumor recurrence. Small nodular and linear enhancement of leptomeninges at brainstem or cerebellar surface is considered as the early manifestation of intracranial tumor seeding.

  19. Contrast enhanced MR imaging of postoperative medulloblastoma in childhood: emphasis on meningeal enhancement

    International Nuclear Information System (INIS)

    Choi, Choong Gon; Kim, In One; Kim, Woo Sun; Kim, Ho Chul; Yeon, Kyung Mo

    1993-01-01

    To differentiate the postoperative changes from the recurrence of tumor and to evaluate MR imaging of early postoperative leptomeningeal seeding in medulloblastoma, We have retrospectively analysed 34 cases of MR images of 17 patients who were confirmed as medulloblastoma by histopathology. Noncontrast and postcontrast T1 weighted MR images were obtained in all patients. In 11 patients follow-up MR was done more than once (average: 1.5 times) and average interval of MR imaging was 6 months. The timing of 34 MR images was as follow: 6 case within 2 months, 9 cases between 2 months and 1 year, 19 cases more than 1 year after surgery respectively. MR images within 2 month after surgery revealed contrast enhancement at operation site and adjacent meninges, hemorrhage, residual tumor. In patients who had no evidence of tumor recurrence, these early postoperative changes were markedly decreased within 6 month after surgery. MR images obtained more than 1 year after surgery showed no abnormal contrast enhancement or mild focal dural enhancement at operation site. Diffuse moderate dural enhancement was noted in one patient who had the history of post-surgical subdural hemorrhage. In six patients with tumor recurrences which were detected from as early as 9 months to 6 years after surgery, the findings of recurrence included leptomeningeal enhancement of brain stem and cerebellar surface at early stage, variable sized enhancing leptomeningeal nodules, linear or irregular sulcus obliterating enhancing lesions, enhancing mass at primary or metastatic site. We have concluded that leptomeningeal enhancement detected after 6 months of surgery is an important MR finding suggesting the possibility of tumor recurrence. Small nodular and linear enhancement of leptomeninges at brainstem or cerebellar surface is considered as the early manifestation of intracranial tumor seeding

  20. Dynamic contrast enhanced MRI study of primary primitive neuroectodermal tumor in the thoracic spine

    International Nuclear Information System (INIS)

    Chen Yu; Xu Jianmin; Li Ying; Zhang Jingzhong; Zhu Jing

    2004-01-01

    Objective: To investigate the value of dynamic contrast-enhanced MR imaging in the diagnosis and differentiation of primitive neuroectodermal tumor (PNET) in the thoracic spine. Methods: The dynamic contrast-enhanced MR imaging of 2 patients (3 times) with PNET in the thoracic spine proved by surgery and pathology were prospectively studied. Results: In the curves of SI-time and CER-time, PNET in the thoracic spine showed a rapid rise to the peak between 60 s and 120 s, then the flat level was kept and no obvious decline was detected after about 3.5 minute. Conclusion: Dynamic contrast-enhanced MRI can help to make the diagnosis and differential diagnosis for PNET in the thoracic spine, offer reliable information for the choice of clinical management, and predict the prognosis

  1. Real-time tsunami inundation forecasting and damage mapping towards enhancing tsunami disaster resiliency

    Science.gov (United States)

    Koshimura, S.; Hino, R.; Ohta, Y.; Kobayashi, H.; Musa, A.; Murashima, Y.

    2014-12-01

    With use of modern computing power and advanced sensor networks, a project is underway to establish a new system of real-time tsunami inundation forecasting, damage estimation and mapping to enhance society's resilience in the aftermath of major tsunami disaster. The system consists of fusion of real-time crustal deformation monitoring/fault model estimation by Ohta et al. (2012), high-performance real-time tsunami propagation/inundation modeling with NEC's vector supercomputer SX-ACE, damage/loss estimation models (Koshimura et al., 2013), and geo-informatics. After a major (near field) earthquake is triggered, the first response of the system is to identify the tsunami source model by applying RAPiD Algorithm (Ohta et al., 2012) to observed RTK-GPS time series at GEONET sites in Japan. As performed in the data obtained during the 2011 Tohoku event, we assume less than 10 minutes as the acquisition time of the source model. Given the tsunami source, the system moves on to running tsunami propagation and inundation model which was optimized on the vector supercomputer SX-ACE to acquire the estimation of time series of tsunami at offshore/coastal tide gauges to determine tsunami travel and arrival time, extent of inundation zone, maximum flow depth distribution. The implemented tsunami numerical model is based on the non-linear shallow-water equations discretized by finite difference method. The merged bathymetry and topography grids are prepared with 10 m resolution to better estimate the tsunami inland penetration. Given the maximum flow depth distribution, the system performs GIS analysis to determine the numbers of exposed population and structures using census data, then estimates the numbers of potential death and damaged structures by applying tsunami fragility curve (Koshimura et al., 2013). Since the tsunami source model is determined, the model is supposed to complete the estimation within 10 minutes. The results are disseminated as mapping products to

  2. Space-time relationship in continuously moving table method for large FOV peripheral contrast-enhanced magnetic resonance angiography

    International Nuclear Information System (INIS)

    Sabati, M; Lauzon, M L; Frayne, R

    2003-01-01

    Data acquisition using a continuously moving table approach is a method capable of generating large field-of-view (FOV) 3D MR angiograms. However, in order to obtain venous contamination-free contrast-enhanced (CE) MR angiograms in the lower limbs, one of the major challenges is to acquire all necessary k-space data during the restricted arterial phase of the contrast agent. Preliminary investigation on the space-time relationship of continuously acquired peripheral angiography is performed in this work. Deterministic and stochastic undersampled hybrid-space (x, k y , k z ) acquisitions are simulated for large FOV peripheral runoff studies. Initial results show the possibility of acquiring isotropic large FOV images of the entire peripheral vascular system. An optimal trade-off between the spatial and temporal sampling properties was found that produced a high-spatial resolution peripheral CE-MR angiogram. The deterministic sampling pattern was capable of reconstructing the global structure of the peripheral arterial tree and showed slightly better global quantitative results than stochastic patterns. Optimal stochastic sampling patterns, on the other hand, enhanced small vessels and had more favourable local quantitative results. These simulations demonstrate the complex spatial-temporal relationship when sampling large FOV peripheral runoff studies. They also suggest that more investigation is required to maximize image quality as a function of hybrid-space coverage, acquisition repetition time and sampling pattern parameters

  3. Volume navigation with contrast enhanced ultrasound and image fusion for percutaneous interventions: first results.

    Directory of Open Access Journals (Sweden)

    Ernst Michael Jung

    Full Text Available OBJECTIVE: Assessing the feasibility and efficiency of interventions using ultrasound (US volume navigation (V Nav with real time needle tracking and image fusion with contrast enhanced (ce CT, MRI or US. METHODS: First an in vitro study on a liver phantom with CT data image fusion was performed, involving the puncture of a 10 mm lesion in a depth of 5 cm performed by 15 examiners with US guided freehand technique vs. V Nav for the purpose of time optimization. Then 23 patients underwent ultrasound-navigated biopsies or interventions using V Nav image fusion of live ultrasound with ceCT, ceMRI or CEUS, which were acquired before the intervention. A CEUS data set was acquired in all patients. Image fusion was established for CEUS and CT or CEUS and MRI using anatomical landmarks in the area of the targeted lesion. The definition of a virtual biopsy line with navigational axes targeting the lesion was achieved by the usage of sterile trocar with a magnetic sensor embedded in its distal tip employing a dedicated navigation software for real time needle tracking. RESULTS: The in vitro study showed significantly less time needed for the simulated interventions in all examiners when V Nav was used (p<0.05. In the study involving patients, in all 10 biopsies of suspect lesions of the liver a histological confirmation was achieved. We also used V Nav for a breast biopsy (intraductal carcinoma, for a biopsy of the abdominal wall (metastasis of ovarial carcinoma and for radiofrequency ablations (4 ablations. In 8 cases of inflammatory abdominal lesions 9 percutaneous drainages were successfully inserted. CONCLUSION: Percutaneous biopsies and drainages, even of small lesions involving complex access pathways, can be accomplished with a high success rate by using 3D real time image fusion together with real time needle tracking.

  4. Intrahepatic portal-hepatic venous shunt diagnosed by ultrasonography and computed tomography. Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Shinagawa, Takashi; Iino, Yasuo; Ukaji, Haruyasu; Ishizuka, Masaharu

    1986-02-01

    Two cases of intrahepatic portal-hepatic venous shunt found by ultrasonography and computed tomography are reported. The first case came to the hospital because of hematuria. A large shunt between the portal vein and the hepatic vein was demonstrated by ultrasonography done for screening, and confirmed by percutaneous transhepatic portography (PTP). The second case was admitted because of cholelithiasis. Computed tomography with contrast enhancement revealed a dilated portal vein in the upper portion of the right lobe. It was subsequently shown by PTP to be a portal-hepatic venous shunt. Portal vein pressure and histological finding of the liver were normal in both cases. The etiology of the shunt was thought to be congenital in these cases for lack of liver disease, portal hypertension and history of trauma. Both cases had no history of hepatic encephalopathy and did not show any symptom attributable to the shunt.

  5. Comparative study of ß-glucan induced respiratory burst measured by nitroblue tetrazolium assay and real-time luminol-enhanced chemiluminescence assay in common carp (Cyprinus carpio L.)

    DEFF Research Database (Denmark)

    Jiménez, Natalia Ivonne Vera; Pietretti, D.; Wiegertjes, G. F.

    2013-01-01

    kidney cells of carp. However, whereas the NBT assay was shown to detect the production of only superoxide anions, the real-time luminol-enhanced assay could detect the production of both superoxide anions and hydrogen peroxide. Only the chemiluminescence assay could reliably record the production of ROS......-point measurement based on the intracellular reduction of nitroblue tetrazolium (NBT) and a real-time luminol-enhanced assay based on the detection of native chemiluminescence. Both assays allowed for detection of dose-dependent changes in magnitude of the respiratory burst response induced by β-glucans in head...... on a real-time scale at frequent and continual time intervals for time course experiments, providing more detailed information on the respiratory burst response. The real-time chemiluminescence assay was used to measure respiratory burst activity in macrophage and neutrophilic granulocyte-enriched head...

  6. Replacing OSE with Real Time capable Linux

    OpenAIRE

    Boman, Simon; Rutgersson, Olof

    2009-01-01

    For many years OSE has been a common used operating system, with real time extensions enhancements, in embed-ded systems. But in the last decades, Linux has grown and became a competitor to common operating systems and, in recent years, even as an operating system with real time extensions. With this in mind, ÅF was interested in replacing the quite expensive OSE with some distribution of the open source based Linux on a PowerPC MPC8360. Therefore, our purpose with thesis is to implement Linu...

  7. Preliminary studies of enhanced contrast radiography in anatomy and embryology of insects with Elettra synchrotron light

    International Nuclear Information System (INIS)

    Hoennicke, M.G.; Foerster, L.A.; Navarro-Silva, M.A.; Menk, R.-H.; Rigon, L.; Cusatis, C.

    2005-01-01

    Enhanced contrast X-ray imaging is achieved by exploiting the real part of the refraction index, which is responsible for the phase shifts, in addition to the imaginary part, which is responsible for the absorption. Such techniques are called X-ray phase contrast imaging. An analyzer-based X-ray phase contrast imaging set-up with Diffraction Enhanced Imaging processing (DEI) were used for preliminary studies in anatomy and embryology of insects. Parasitized stinkbug and moth eggs used as control agents of pests in vegetables and adult stinkbugs and mosquitoes (Aedes aegypti) were used as samples. The experimental setup was mounted in the SYRMEP beamline at ELETTRA. Images were obtained using a high spatial resolution CCD detector (pixel size 14x14μm 2 ) coupled with magnifying optics. Analyzer-based X-ray phase contrast images (PCI) and edge detection images show contrast and details not observed with conventional synchrotron radiography and open the possibility for future study in the embryonic development of insects

  8. Diagnostic imaging in companion animal theriogenology

    International Nuclear Information System (INIS)

    Root, C.R.; Spaulding, K.A.

    1994-01-01

    Clinical assessment of reproductive problems in companion animals is greatly enhanced by the availability of various imaging modalities. Specifically, survey radiography, contrast radiography, real-time ultrasonography, and ultrasound-guided biopsy and/or aspiration cytology, alone or in various combinations, offer sophisticated methods of extension of the physical examination of the reproductive systems of dogs and cats. In particular, real-time ultrasonography offers invaluable assistance. It is nonionizing, largely noninvasive, rapid, and capable of providing certain dynamic information that is not conveniently available in any other way. Judging from its rapid growth in recent years, it has apparently become an integral part of the complete reproductive assessment of domestic animals. This is not to slight the importance of some of the contrast radiographic procedures that have been developed and refined. Some of them, such as maximum distention retrograde urothrocystography, provide unique information not available with presently routinely used ultrasound techniques. Other imaging modalities, such as magnetic resonance imaging, have heretofore provided limited benefit to theriogenology; that will probably change in years to come

  9. Radiochromic film dosimetry of contrast-enhanced radiotherapy (CERT)

    International Nuclear Information System (INIS)

    Morris, Kevin N; Weil, Michael D; Malzbender, Rainer

    2006-01-01

    Contrast-enhanced radiotherapy (CERT) employs elevated concentrations of high-Z contrast media in targets to dramatically increase the absorbed dose of radiation relative to the surrounding tissues. However, it is difficult to measure the dose enhancement with routine clinical instruments because the photoelectrons and Auger electrons produced by the interaction of kilovoltage x-rays with the contrast agent travel extremely short distances. We have developed a technique utilizing unlaminated radiochromic film to measure the maximum dose enhancement factor attainable in solutions of contrast agent with iodine concentrations ranging from 0% to 37% (w/v). The films were also used to simultaneously measure the dose enhancement and beam attenuation through solutions containing 0%, 5% and 10% iodine (w/v). These depth-dose measurements were made in phantoms representing 3 cm targets located 0 and 4.8 cm deep in acrylic. Higher concentrations of contrast yielded greater dose enhancement and target-to-surface dose ratios, but caused more rapid attenuation of the beam as it traversed the target. The dose distribution across the entire target could be improved by employing multiple beams. These results, using concentrations of contrast that are clinically achievable by intratumoural injection, illustrate the potential of CERT for the specific delivery of high doses of radiation to targets at depth

  10. Contrast-enhanced CISS imaging of cerebellopontine angle tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tozaki, Mitsuhiro; Toyoda, Keiko; Hata, Yuichi; Fukuda, Yasushi; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine; Katano, Shuichi

    1999-10-01

    Our purpose of this study was to evaluate the clinical usefulness of contrast-enhanced CISS-3DFT MR imaging for the diagnosis of CP angle tumors. CISS-3DFT MR imaging is expected for screening procedure of acoustic schwannoma because of excellent spatial resolution. Recently, we discovered contrast enhancement effect on CISS sequence in spite of heavily T{sub 2}-weighted images. Fourteen patients with CP angle tumors were performed on a 1.0 T MR unit. Transaxial CISS-3DFT MRI was obtained both before and after intravenous injections of Gd-DTPA. Multiplanar reconstructions (MPRs) were performed in all cases. Contrast enhancement effect of CP angle tumors, and the relationship between tumors and the adjacent cranial nerves were evaluated. Contrast enhancement effect of the tumors was present in all cases in spite of heavily T{sub 2}-weighted images of CISS sequences. In the internal auditory canal, relationship between the tumors and the cranial nerves was demonstrated in 6 cases (6/9). In the cerebellopontine cistern, all cases were demonstrated (11/11). Contrast-enhanced CISS-3DFT MR imaging with a good contrast resolution and an excellent spatial resolution is useful for the diagnosis of CP angle tumors. (author)

  11. Brain capillary transit time heterogeneity in healthy volunteers measured by dynamic contrast-enhanced T1-weighted perfusion MRI

    DEFF Research Database (Denmark)

    Larsson, Henrik B.W.; Vestergaard, Mark B.; Lindberg, Ulrich

    2017-01-01

    Purpose: Capillary transit time heterogeneity, measured as CTH, may set the upper limit for extraction of substances in brain tissue, e.g., oxygen. The purpose of this study was to investigate the feasibility of dynamic contrast-enhanced T1 weighted MRI (DCE-MRI) at 3 Tesla (T), in estimating CTH...

  12. Generalized image contrast enhancement technique based on Heinemann contrast discrimination model

    Science.gov (United States)

    Liu, Hong; Nodine, Calvin F.

    1994-03-01

    This paper presents a generalized image contrast enhancement technique which equalizes perceived brightness based on the Heinemann contrast discrimination model. This is a modified algorithm which presents an improvement over the previous study by Mokrane in its mathematically proven existence of a unique solution and in its easily tunable parameterization. The model uses a log-log representation of contrast luminosity between targets and the surround in a fixed luminosity background setting. The algorithm consists of two nonlinear gray-scale mapping functions which have seven parameters, two of which are adjustable Heinemann constants. Another parameter is the background gray level. The remaining four parameters are nonlinear functions of gray scale distribution of the image, and can be uniquely determined once the previous three are given. Tests have been carried out to examine the effectiveness of the algorithm for increasing the overall contrast of images. It can be demonstrated that the generalized algorithm provides better contrast enhancement than histogram equalization. In fact, the histogram equalization technique is a special case of the proposed mapping.

  13. Ionic and non-ionic contrast media used for contrast-enhanced computed tomography in experimental pancreatitis

    International Nuclear Information System (INIS)

    Kivisaari, L.; Nuutinen, P.; Lehtola, A.; Saari, A.; Pitkaeranta, P.; Standertskjoeld-Nordenstam, C.G.; Lempinen, M.; Schroeder, T.; Helsinki Univ. Central Hospital

    1988-01-01

    Contrast enhancement of the pancreas was studied in pigs using dynamic computed tomography in experimental oedematous and haemorrhagic/necrotizing pancreatitis during the first two minutes after injection of an intravenous bolus of non-ionic contrast medium (iohexol). The prospects of separating the two forms of the disease, known to be possible with ionic contrast media, were tested with a non-ionic contrast medium. In the oedematous form, contrast enhancement after 5 hours of the disease was significantly higher than in the haemorrhagic/necrotizing form. Contrast enhancement after 30 hours of disease tended to vary with the severity of the disease, showing that the course of oedematous pancreatitis is dynamic. Intermediate forms occur and follow-up studies are needed during the disease. A non-ionic contrast medium proved as good for separating the two forms of the disease in the early phase as were ionic contrast media. In severely ill patients, non-ionic contrast media should therefore be used. (orig.)

  14. Real Time Revisited

    Science.gov (United States)

    Allen, Phillip G.

    1985-12-01

    The call for abolishing photo reconnaissance in favor of real time is once more being heard. Ten years ago the same cries were being heard with the introduction of the Charge Coupled Device (CCD). The real time system problems that existed then and stopped real time proliferation have not been solved. The lack of an organized program by either DoD or industry has hampered any efforts to solve the problems, and as such, very little has happened in real time in the last ten years. Real time is not a replacement for photo, just as photo is not a replacement for infra-red or radar. Operational real time sensors can be designed only after their role has been defined and improvements made to the weak links in the system. Plodding ahead on a real time reconnaissance suite without benefit of evaluation of utility will allow this same paper to be used ten years from now.

  15. Preoperative evaluation of neurovascular relationship by using contrast-enhanced and unenhanced 3D time-of-flight MR angiography in patients with trigeminal neuralgia

    International Nuclear Information System (INIS)

    Qin, Zhou; Zhiling, Liu; Chuanfu, Li; Qingshi Zeng; Chuncheng, Qu; Shilei, Ni

    2011-01-01

    Background Microvascular decompression is an etiological strategy for the therapy of trigeminal neuralgia (TN). Preoperative identification of neurovascular compression, therefore, could have an impact on the determination of appropriate treatment for TN. Purpose To evaluate the value of contrast-enhanced and unenhanced three-dimensional (3D) time-of-flight (TOF) MR angiography in the visualization of neurovascular relationship in patients with TN. Material and Methods Thirty-seven patients with unilateral TN underwent unenhanced and contrast-enhanced 3D TOF MR angiography with a 3.0-T MR system. Images were reviewed by a radiologist blinded to clinical details. Vascular contact with the trigeminal nerve was identified, and the nature of the involved vessels (artery or vein) was determined. All patients underwent microvascular decompression. Results In 37 patients with TN, contrast-enhanced 3D TOF MR angiography identified surgically verified neurovascular contact in 35 of 36 symptomatic nerves, and there was no false-positive. Based on surgical findings, the sensitivity of MR imaging was 97.2% and specificity 100%. The nature of the offending vessel was correctly identified in 94.4% of the patients by using the combination of contrast-enhanced and unenhanced MR angiography. Conclusion Contrast-enhanced 3D TOF MR angiography is useful in the detection of vascular contact with the trigeminal nerve in patients with TN, and this MR imaging in combination with unenhanced MR angiography could help in the identification of the nature of the responsible vessels

  16. Fast mutual-information-based contrast enhancement

    Science.gov (United States)

    Cao, Gang; Yu, Lifang; Tian, Huawei; Huang, Xianglin; Wang, Yongbin

    2017-07-01

    Recently, T. Celik proposed an effective image contrast enhancement (CE) method based on spatial mutual information and PageRank (SMIRANK). According to the state-of-the-art evaluation criteria, it achieves the best visual enhancement quality among existing global CE methods. However, SMIRANK runs much slower than the other counterparts, such as histogram equalization (HE) and adaptive gamma correction. Low computational complexity is also required for good CE algorithms. In this paper, we novelly propose a fast SMIRANK algorithm, called FastSMIRANK. It integrates both spatial and gray-level downsampling into the generation of pixel value mapping function. Moreover, the computation of rank vectors is speeded up by replacing PageRank with a simple yet efficient row-based operation of mutual information matrix. Extensive experimental results show that the proposed FastSMIRANK could accelerate the processing speed of SMIRANK by about 20 times, and is even faster than HE. Comparable enhancement quality is preserved simultaneously.

  17. Enhancement tuning and control for high dynamic range images in multi-scale locally adaptive contrast enhancement algorithms

    NARCIS (Netherlands)

    Cvetkovic, S.D.; Schirris, J.; With, de P.H.N.

    2009-01-01

    For real-time imaging in surveillance applications, visibility of details is of primary importance to ensure customer confidence. If we display High Dynamic-Range (HDR) scenes whose contrast spans four or more orders of magnitude on a conventional monitor without additional processing, results are

  18. Sepsis patients' renal manifestation on contrast-enhanced CT

    International Nuclear Information System (INIS)

    Sasaguri, K.; Yamaguchi, K.; Nakazono, T.; Mizuguchi, M.; Irie, H.

    2016-01-01

    Aim: To evaluate renal volume and attenuation changes in patients with sepsis on contrast-enhanced computed tomography (CT) with respect to the severity of sepsis. Materials and methods: Forty-four patients with sepsis who underwent CT before and after the onset of sepsis were retrospectively analysed. Renal volume and CT attenuation value of the renal cortex on contrast-enhanced CT were measured for each patient and changes in renal volume and CT attenuation value from before to after the onset of sepsis were calculated. The changes were correlated with the severity of sepsis (Sepsis-related Organ Failure Assessment [SOFA] score). The time course of the renal volume and CT attenuation changes were also evaluated. Results: Renal volume increased by 17.6% and CT attenuation value decreased by 19% after the onset of sepsis with statistically significant differences (p<0.001 for both renal volume and CT attenuation changes). The renal volume and CT attenuation changes had significant correlations with the SOFA score (r=0.36, p=0.018 and −0.43, p=0.005, respectively). The time course of the renal volume and CT attenuation changes seemed to be gradual compared to that of the SOFA score and to lag behind the peak of the SOFA score. Conclusion: In patients with sepsis, the renal volume increases and the CT attenuation value decreases in proportion to the severity of sepsis. The changes may lag behind the peak of severity of sepsis and can be observed for a relatively long time after a patient's recovery from sepsis. - Highlights: • The renal volume increases and the renal enhancement on contrast-enhanced CT decreases in patients with sepsis. • The degrees of these changes are correlated with severity of sepsis. • These changes may lag behind the peak of severity of sepsis and last for a long time after a patient's recovery from sepsis.

  19. Sequential contrast-enhanced MR imaging of the penis.

    Science.gov (United States)

    Kaneko, K; De Mouy, E H; Lee, B E

    1994-04-01

    To determine the enhancement patterns of the penis at magnetic resonance (MR) imaging. Sequential contrast material-enhanced MR images of the penis in a flaccid state were obtained in 16 volunteers (12 with normal penile function and four with erectile dysfunction). Subjects with normal erectile function showed gradual and centrifugal enhancement of the corpora cavernosa, while those with erectile dysfunction showed poor enhancement with abnormal progression. Sequential contrast-enhanced MR imaging provides additional morphologic information for the evaluation of erectile dysfunction.

  20. Contrast-enhanced flair imaging in the evaluation of infectious leptomeningeal diseases

    International Nuclear Information System (INIS)

    Parmar, Hemant; Sitoh, Y.-Y.; Anand, Pooja; Chua, Violet; Hui, Francis

    2006-01-01

    Purpose: The purpose of our study was to compare contrast-enhanced fluid-attenuated inversion recovery (FLAIR) images with contrast-enhanced T1 weighted images for infectious leptomeningitis. Materials and methods: We studied twenty-four patients with a clinical suspicion of infectious meningitis with unenhanced FLAIR, contrast-enhanced T1 weighted and contrast-enhanced FLAIR MR sequences. Twelve patients had cytologic and biochemical diagnosis of meningitis on cerebrospinal fluid (CSF) examination obtained 48 h before or after the MR study. Sequences were considered positive if abnormal signal was seen in the subarachnoid space (cistern or sulci) or along pial surface. Results: Twenty-seven examinations in 24 patients were performed. Of the 12 patients (thirteen studies) in whom cytology was positive, unenhanced FLAIR images were positive in six cases (sensitivity 46%), contrast-enhanced FLAIR images were positive in 11 (sensitivity 85%), and contrast-enhanced T1 weighted MR images were positive in 11 patients (sensitivity 85%). Of the 12 patients (14 studies) in whom cerebrospinal fluid study was negative, unenhanced FLAIR images were negative in 13, contrast-enhanced FLAIR images were negative in 11, and contrast-enhanced T1 weighted MR images were negative in eight. Thus, the specificity of unenhanced FLAIR, contrast-enhanced FLAIR and contrast-enhanced T1 weighted images was 93, 79 and 57%, respectively. Conclusion: Our results suggest that post-contrast FLAIR images have similar sensitivity but a higher specificity compared to contrast-enhanced T1 weighted images for detection of leptomeningeal enhancement. It can be a useful adjunct to post-contrast T1 weighted images in evaluation of infectious leptomeningitis

  1. Contrast-enhanced flair imaging in the evaluation of infectious leptomeningeal diseases

    Energy Technology Data Exchange (ETDEWEB)

    Parmar, Hemant [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore) and Department of Diagnostic Imaging, Hospital for Sick Children, Toronto (Canada)]. E-mail: parurad@hotmail.com; Sitoh, Y.-Y. [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Anand, Pooja [Department of Neurology, National Neuroscience Institute, 11 Jalan Tan Tock Seng (Singapore); Chua, Violet [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Hui, Francis [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore)

    2006-04-15

    Purpose: The purpose of our study was to compare contrast-enhanced fluid-attenuated inversion recovery (FLAIR) images with contrast-enhanced T1 weighted images for infectious leptomeningitis. Materials and methods: We studied twenty-four patients with a clinical suspicion of infectious meningitis with unenhanced FLAIR, contrast-enhanced T1 weighted and contrast-enhanced FLAIR MR sequences. Twelve patients had cytologic and biochemical diagnosis of meningitis on cerebrospinal fluid (CSF) examination obtained 48 h before or after the MR study. Sequences were considered positive if abnormal signal was seen in the subarachnoid space (cistern or sulci) or along pial surface. Results: Twenty-seven examinations in 24 patients were performed. Of the 12 patients (thirteen studies) in whom cytology was positive, unenhanced FLAIR images were positive in six cases (sensitivity 46%), contrast-enhanced FLAIR images were positive in 11 (sensitivity 85%), and contrast-enhanced T1 weighted MR images were positive in 11 patients (sensitivity 85%). Of the 12 patients (14 studies) in whom cerebrospinal fluid study was negative, unenhanced FLAIR images were negative in 13, contrast-enhanced FLAIR images were negative in 11, and contrast-enhanced T1 weighted MR images were negative in eight. Thus, the specificity of unenhanced FLAIR, contrast-enhanced FLAIR and contrast-enhanced T1 weighted images was 93, 79 and 57%, respectively. Conclusion: Our results suggest that post-contrast FLAIR images have similar sensitivity but a higher specificity compared to contrast-enhanced T1 weighted images for detection of leptomeningeal enhancement. It can be a useful adjunct to post-contrast T1 weighted images in evaluation of infectious leptomeningitis.

  2. Operational characteristic analysis of conduction cooling HTS SMES for Real Time Digital Simulator based power quality enhancement simulation

    International Nuclear Information System (INIS)

    Kim, A.R.; Kim, G.H.; Kim, K.M.; Kim, D.W.; Park, M.; Yu, I.K.; Kim, S.H.; Sim, K.; Sohn, M.H.; Seong, K.C.

    2010-01-01

    This paper analyzes the operational characteristics of conduction cooling Superconducting Magnetic Energy Storage (SMES) through a real hardware based simulation. To analyze the operational characteristics, the authors manufactured a small-scale toroidal-type SMES and implemented a Real Time Digital Simulator (RTDS) based power quality enhancement simulation. The method can consider not only electrical characteristics such as inductance and current but also temperature characteristic by using the real SMES system. In order to prove the effectiveness of the proposed method, a voltage sag compensation simulation has been implemented using the RTDS connected with the High Temperature Superconducting (HTS) model coil and DC/DC converter system, and the simulation results are discussed in detail.

  3. Adaptive multiscale processing for contrast enhancement

    Science.gov (United States)

    Laine, Andrew F.; Song, Shuwu; Fan, Jian; Huda, Walter; Honeyman, Janice C.; Steinbach, Barbara G.

    1993-07-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis through overcomplete multiresolution representations. We show that efficient representations may be identified from digital mammograms within a continuum of scale space and used to enhance features of importance to mammography. Choosing analyzing functions that are well localized in both space and frequency, results in a powerful methodology for image analysis. We describe methods of contrast enhancement based on two overcomplete (redundant) multiscale representations: (1) Dyadic wavelet transform (2) (phi) -transform. Mammograms are reconstructed from transform coefficients modified at one or more levels by non-linear, logarithmic and constant scale-space weight functions. Multiscale edges identified within distinct levels of transform space provide a local support for enhancement throughout each decomposition. We demonstrate that features extracted from wavelet spaces can provide an adaptive mechanism for accomplishing local contrast enhancement. We suggest that multiscale detection and local enhancement of singularities may be effectively employed for the visualization of breast pathology without excessive noise amplification.

  4. Real-time MRI of the temporomandibular joint at 15 frames per second—A feasibility study

    International Nuclear Information System (INIS)

    Krohn, Sebastian; Gersdorff, Nikolaus; Wassmann, Torsten; Merboldt, Klaus-Dietmar; Joseph, Arun A.; Buergers, Ralf; Frahm, Jens

    2016-01-01

    The purpose of this study was to develop and evaluate a novel method for real-time MRI of TMJ function at high temporal resolution and with two different contrasts. Real-time MRI was based on undersampled radial fast low angle shot (FLASH) acquisitions with iterative image reconstruction by regularized nonlinear inversion. Real-time MRI movies with T1 contrast were obtained with use of a radiofrequency-spoiled FLASH sequence, while movies with T2/T1 contrast employed a gradient-refocused FLASH version. TMJ function was characterized in 40 randomly selected volunteers by sequential 20 s acquisitions of both the right and left joint during voluntary opening and closing of the mouth (in a medial, central and lateral oblique sagittal section perpendicular to the long axis of the condylar head). All studies were performed on a commercial MRI system at 3 T using the standard head coil, while online reconstruction was achieved with a bypass computer fully integrated into the MRI system. As a first result, real-time MRI studies of the right and left TMJ were successfully performed in all 40 subjects (80 joints) within a total examination time per subject of only 15 min. Secondly, at an in-plane resolution of 0.75 mm and 5 mm section thickness, the achieved temporal resolution was 66.7 ms per image or 15 frames per second. Thirdly, both T1-weighted and T2/T1-weighted real-time MRI movies provided information about TMJ function such as disc position, condyle mobility and disc-condyle relationship. While T1 contrast offers a better delineation of structures during rapid jaw movements, T2/T1 contrast was rated superior for characterizing the articular disc. In conclusion, the proposed real-time MRI method may become a robust and efficient tool for the clinical assessment of TMJ function.

  5. Real-time MRI of the temporomandibular joint at 15 frames per second—A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Krohn, Sebastian; Gersdorff, Nikolaus; Wassmann, Torsten [Department of Prosthodontics, University Medical Center, Göttingen (Germany); Merboldt, Klaus-Dietmar [Biomedizinische NMR Forschungs GmbH am Max-Planck-Institut für Biophysikalische Chemie, Göttingen (Germany); Joseph, Arun A., E-mail: ajoseph@mpibpc.mpg.de [Biomedizinische NMR Forschungs GmbH am Max-Planck-Institut für Biophysikalische Chemie, Göttingen (Germany); Buergers, Ralf [Department of Prosthodontics, University Medical Center, Göttingen (Germany); Frahm, Jens [Biomedizinische NMR Forschungs GmbH am Max-Planck-Institut für Biophysikalische Chemie, Göttingen (Germany)

    2016-12-15

    The purpose of this study was to develop and evaluate a novel method for real-time MRI of TMJ function at high temporal resolution and with two different contrasts. Real-time MRI was based on undersampled radial fast low angle shot (FLASH) acquisitions with iterative image reconstruction by regularized nonlinear inversion. Real-time MRI movies with T1 contrast were obtained with use of a radiofrequency-spoiled FLASH sequence, while movies with T2/T1 contrast employed a gradient-refocused FLASH version. TMJ function was characterized in 40 randomly selected volunteers by sequential 20 s acquisitions of both the right and left joint during voluntary opening and closing of the mouth (in a medial, central and lateral oblique sagittal section perpendicular to the long axis of the condylar head). All studies were performed on a commercial MRI system at 3 T using the standard head coil, while online reconstruction was achieved with a bypass computer fully integrated into the MRI system. As a first result, real-time MRI studies of the right and left TMJ were successfully performed in all 40 subjects (80 joints) within a total examination time per subject of only 15 min. Secondly, at an in-plane resolution of 0.75 mm and 5 mm section thickness, the achieved temporal resolution was 66.7 ms per image or 15 frames per second. Thirdly, both T1-weighted and T2/T1-weighted real-time MRI movies provided information about TMJ function such as disc position, condyle mobility and disc-condyle relationship. While T1 contrast offers a better delineation of structures during rapid jaw movements, T2/T1 contrast was rated superior for characterizing the articular disc. In conclusion, the proposed real-time MRI method may become a robust and efficient tool for the clinical assessment of TMJ function.

  6. Real time magnetic resonance guided endomyocardial local delivery

    Science.gov (United States)

    Corti, R; Badimon, J; Mizsei, G; Macaluso, F; Lee, M; Licato, P; Viles-Gonzalez, J F; Fuster, V; Sherman, W

    2005-01-01

    Objective: To investigate the feasibility of targeting various areas of left ventricle myocardium under real time magnetic resonance (MR) imaging with a customised injection catheter equipped with a miniaturised coil. Design: A needle injection catheter with a mounted resonant solenoid circuit (coil) at its tip was designed and constructed. A 1.5 T MR scanner with customised real time sequence combined with in-room scan running capabilities was used. With this system, various myocardial areas within the left ventricle were targeted and injected with a gadolinium-diethylenetriaminepentaacetic acid (DTPA) and Indian ink mixture. Results: Real time sequencing at 10 frames/s allowed clear visualisation of the moving catheter and its transit through the aorta into the ventricle, as well as targeting of all ventricle wall segments without further image enhancement techniques. All injections were visualised by real time MR imaging and verified by gross pathology. Conclusion: The tracking device allowed real time in vivo visualisation of catheters in the aorta and left ventricle as well as precise targeting of myocardial areas. The use of this real time catheter tracking may enable precise and adequate delivery of agents for tissue regeneration. PMID:15710717

  7. Fibroadenomas of the breast: histopathological/dynamic contrast-enhanced MR correlation

    Energy Technology Data Exchange (ETDEWEB)

    Gilles, R. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Garnier, C. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Meingan, P. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Zemoura, L. [Dept. of Histopathology C, Inst. Gustave Roussy, 94 - Villejuif (France); Lucidarme, O. [Dept. of Radiology, Hopital Salpetriere, 75 - Paris (France); Guinebretiere, J.M. [Dept. of Histopathology C, Inst. Gustave Roussy, 94 - Villejuif (France); Tardivon, A.A. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Arriagada, R. [Breast Cancer Study Group, Inst. Gustave Roussy, 94 - Villejuif, (France)

    1995-12-31

    A total of 22 women with fibroadenomas had preoperative dynamic MR study (T1-weighted images every 47 s after injection of Gd-DOTA). Their age, hormonal status, breast MR studies and histopathological slides were retrospectively reviewed. Eleven pre- (n = 2) or post-menopausal (n = 9) women showed no early contrast enhancement. The absence of early contrast enhancement correlated with hyalin stromal component. Eleven pre- (n = 7) or post-menopausal (n = 4) women showed focal (n = 9) or diffuse (n = 2) early contrast enhancement. Early focal contrast enhancement correlated with myxoid (n = 9), mixed hyalin/myxoid (n = 1) or hyalin (n = 1) fibroadenomas. Early diffuse contrast enhancement of the breast correlated with myxoid (n = 1) or hyalin (n = 1) stromal component associated with proliferative fibrocystic disease of the breast parenchyma. The presence of contrast enhancement correlated with myxoid fibroadenomas, whereas absence of contrast enhancement correlated with hyalin fibroadenomas. As hyalin fibroadenomas occurs in post-menopausal women, the diagnostic accuracy of dynamic MRI may be improved in this age group. (orig.)

  8. Fibroadenomas of the breast: histopathological/dynamic contrast-enhanced MR correlation

    International Nuclear Information System (INIS)

    Gilles, R.; Garnier, C.; Meingan, P.; Zemoura, L.; Lucidarme, O.; Guinebretiere, J.M.; Tardivon, A.A.; Arriagada, R.

    1995-01-01

    A total of 22 women with fibroadenomas had preoperative dynamic MR study (T1-weighted images every 47 s after injection of Gd-DOTA). Their age, hormonal status, breast MR studies and histopathological slides were retrospectively reviewed. Eleven pre- (n = 2) or post-menopausal (n = 9) women showed no early contrast enhancement. The absence of early contrast enhancement correlated with hyalin stromal component. Eleven pre- (n = 7) or post-menopausal (n = 4) women showed focal (n = 9) or diffuse (n = 2) early contrast enhancement. Early focal contrast enhancement correlated with myxoid (n = 9), mixed hyalin/myxoid (n 1) or hyalin (n = 1) fibroadenomas. Early diffuse contrast enhancement of the breast correlated with myxoid (n = 1) or hyalin (n = 1) stromal component associated with proliferative fibrocystic disease of the breast parenchyma. The presence of contrast enhancement correlated with myxoid fibroadenomas, whereas absence of contrast enhancement correlated with hyalin fibroadenomas. As hyalin fibroadenomas occurs in post-menopausal women, the diagnostic accuracy of dynamic MRI may be improved in this age group. (orig.)

  9. USE OF IMAGE ENHANCEMENT TECHNIQUES FOR IMPROVING REAL TIME FACE RECOGNITION EFFICIENCY ON WEARABLE GADGETS

    Directory of Open Access Journals (Sweden)

    MUHAMMAD EHSAN RANA

    2017-01-01

    Full Text Available The objective of this research is to study the effects of image enhancement techniques on face recognition performance of wearable gadgets with an emphasis on recognition rate.In this research, a number of image enhancement techniques are selected that include brightness normalization, contrast normalization, sharpening, smoothing, and various combinations of these. Subsequently test images are obtained from AT&T database and Yale Face Database B to investigate the effect of these image enhancement techniques under various conditions such as change of illumination and face orientation and expression.The evaluation of data, collected during this research, revealed that the effect of image pre-processing techniques on face recognition highly depends on the illumination condition under which these images are taken. It is revealed that the benefit of applying image enhancement techniques on face images is best seen when there is high variation of illumination among images. Results also indicate that highest recognition rate is achieved when images are taken under low light condition and image contrast is enhanced using histogram equalization technique and then image noise is reduced using median smoothing filter. Additionally combination of contrast normalization and mean smoothing filter shows good result in all scenarios. Results obtained from test cases illustrate up to 75% improvement in face recognition rate when image enhancement is applied to images in given scenarios.

  10. Real-time applications of neural nets

    International Nuclear Information System (INIS)

    Spencer, J.E.

    1989-05-01

    Producing, accelerating and colliding very high power, low emittance beams for long periods is a formidable problem in real-time control. As energy has grown exponentially in time so has the complexity of the machines and their control systems. Similar growth rates have occurred in many areas, e.g., improved integrated circuits have been paid for with comparable increases in complexity. However, in this case, reliability, capability and cost have improved due to reduced size, high production and increased integration which allow various kinds of feedback. In contrast, most large complex systems (LCS) are perceived to lack such possibilities because only one copy is made. Neural nets, as a metaphor for LCS, suggest ways to circumvent such limitations. It is argued that they are logically equivalent to multi-loop feedback/forward control of faulty systems. While complimentary to AI, they mesh nicely with characteristics desired for real-time systems. Such issues are considered, examples given and possibilities discussed. 21 refs., 6 figs

  11. Real-time applications of neural nets

    International Nuclear Information System (INIS)

    Spencer, J.E.

    1989-01-01

    Producing, accelerating and colliding very high power, low emittance beams for long periods is a formidable problem in real-time control. As energy has grown exponentially in time so has the complexity of the machines and their control systems. Similar growth rates have occurred in many areas e.g. improved integrated circuits have been paid for with comparable increases in complexity. However, in this case, reliability, capability and cost have improved due to reduced size, high production and increased integration which allow various kinds of feedback. In contrast, most large complex systems (LCS) are perceived to lack such possibilities because only one copy is made. Neural nets, as a metaphor for LCS, suggest ways to circumvent such limitations. It is argued that they are logically equivalent to multi-loop feedback/forward control of faulty systems. While complimentary to AI, they mesh nicely with characteristics desired for real-time systems. In this paper, such issues are considered, examples given and possibilities discussed

  12. Real-time applications of neural nets

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, J.E.

    1989-05-01

    Producing, accelerating and colliding very high power, low emittance beams for long periods is a formidable problem in real-time control. As energy has grown exponentially in time so has the complexity of the machines and their control systems. Similar growth rates have occurred in many areas, e.g., improved integrated circuits have been paid for with comparable increases in complexity. However, in this case, reliability, capability and cost have improved due to reduced size, high production and increased integration which allow various kinds of feedback. In contrast, most large complex systems (LCS) are perceived to lack such possibilities because only one copy is made. Neural nets, as a metaphor for LCS, suggest ways to circumvent such limitations. It is argued that they are logically equivalent to multi-loop feedback/forward control of faulty systems. While complimentary to AI, they mesh nicely with characteristics desired for real-time systems. Such issues are considered, examples given and possibilities discussed. 21 refs., 6 figs.

  13. Shoulder Magnetic Resonance Arthrography: A Prospective Randomized Study of Anterior and Posterior Ultrasonography-Guided Contrast Injections

    Energy Technology Data Exchange (ETDEWEB)

    Koivikko, M.P.; Mustonen, A.O.T. (Dept. of Radiology, Helsinki Univ. Central Hospital, Helsinki (Finland))

    2008-10-15

    Background: Magnetic resonance (MR) arthrography is an accurate imaging method for internal shoulder derangements and rotator cuff pathologies. Both anterior and posterior contrast injection techniques, under palpatory, fluoroscopic, or ultrasonographic guidance have been described in the literature. However, clinical comparisons of the injection techniques remain few. Purpose: To compare the performance of anterior and posterior ultrasonography (US)-guided arthrography injections of the shoulder regarding patient discomfort and influence on diagnostic MR reading, and to illustrate the typical artifacts resulting from contrast leakage in the respective techniques. Material and Methods: 43 MR arthrographies were prospectively randomized into anterior and posterior US-guided contrast injections and performed by two radiologists, with the study of artifacts from contrast leakage. Pain from the injections was assessed by a survey utilizing a 100-mm visual analogue scale (VAS). Results: Of the 23 anterior injections, nine caused contrast artifacts in the subscapular tendon, and in three the leakage extended further anteriorly. Of the 20 posterior injections, 12 showed injection artifacts of the rotator cuff, extending outside the cuff in seven. Two of the anterior and none of the posterior artifacts compromised diagnostic quality. In posterior injections, the leakage regularly occurred at the caudal edge of the infraspinatus muscle and was easily distinguishable from rotator cuff tears. All patients completed the pain survey. Mean VAS scores were 25.0 (median 18, SD 22) for anterior, and 25.4 (median 16, SD 25) for posterior injections. The two radiologists achieved different mean VAS scores but closely agreed as to anterior and posterior VAS scores. Conclusion: Arthrography injections were fairly simple to perform under US guidance. Patient discomfort for anterior and posterior injections was equally minor. A tailored approach utilizing anterior or posterior injections

  14. Estimating the arterial input function from dynamic contrast-enhanced MRI data with compensation for flow enhancement (I): Theory, method, and phantom experiments

    NARCIS (Netherlands)

    van Schie, Jeroen J. N.; Lavini, Cristina; van Vliet, Lucas J.; Vos, Frans M.

    2017-01-01

    The arterial input function (AIF) represents the time-dependent arterial contrast agent (CA) concentration that is used in pharmacokinetic modeling. To develop a novel method for estimating the AIF from dynamic contrast-enhanced (DCE-) MRI data, while compensating for flow enhancement. Signal

  15. Comparison of the Mammography, Contrast-Enhanced Spectral Mammography and Ultrasonography in a Group of 116 patients.

    Science.gov (United States)

    Luczyńska, Elzbieta; Heinze, Sylwia; Adamczyk, Agnieszka; Rys, Janusz; Mitus, Jerzy W; Hendrick, Edward

    2016-08-01

    Mammography (MG) is the gold-standard in breast cancer detection - the only method documented to reduce breast cancer mortality. Breast ultrasound (US) has been shown to increase sensitivity to breast cancers in screening women with dense breasts. Contrast-enhanced spectral mammography (CESM) is a novel technique intensively developed in the last few years. The goal of this study was to compare the sensitivity, specificity and accuracy of MG, US and CESM in detecting malignant breast lesions. The study included 116 patients. All patients were symptomatic and underwent MG, US and CESM. A radiologist with 20 years of experience in US and MG breast imaging and 1 year of experience in CESM reviewed images acquired in each of the three modalities separately, within an interval of 14-30 days. All identified lesions were confirmed at core biopsy. BI-RADS classifications on US, MG and CESM were compared to histopathology. MG, CESM and US were compared among 116 patients with 137 lesions encountered. Sensitivity of CESM was 100%, significantly higher than that of MG (90%, p<0.004) or US (92%, p<0.01). CESM accuracy was 78%, also higher than MG (69%, p<0.004) and US (70%, p=0.03). There was no statistically significant difference between AUCs for CESM and US (both 0.83). The AUCs of both US and CESM, however, were significantly larger than that of MG (p<0.0004 for each). CESM permitted better detection of malignant lesions than both MG and US, read individually. CESM found lesion enhancement in some benign lesions, as well, yielding a rate of false-positive diagnoses similar to that of MG and US. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  16. Color reproduction and processing algorithm based on real-time mapping for endoscopic images.

    Science.gov (United States)

    Khan, Tareq H; Mohammed, Shahed K; Imtiaz, Mohammad S; Wahid, Khan A

    2016-01-01

    In this paper, we present a real-time preprocessing algorithm for image enhancement for endoscopic images. A novel dictionary based color mapping algorithm is used for reproducing the color information from a theme image. The theme image is selected from a nearby anatomical location. A database of color endoscopy image for different location is prepared for this purpose. The color map is dynamic as its contents change with the change of the theme image. This method is used on low contrast grayscale white light images and raw narrow band images to highlight the vascular and mucosa structures and to colorize the images. It can also be applied to enhance the tone of color images. The statistic visual representation and universal image quality measures show that the proposed method can highlight the mucosa structure compared to other methods. The color similarity has been verified using Delta E color difference, structure similarity index, mean structure similarity index and structure and hue similarity. The color enhancement was measured using color enhancement factor that shows considerable improvements. The proposed algorithm has low and linear time complexity, which results in higher execution speed than other related works.

  17. Real-time molecular imaging throughout the entire cell cycle by targeted plasmonic-enhanced Rayleigh/Raman spectroscopy.

    Science.gov (United States)

    Kang, Bin; Austin, Lauren A; El-Sayed, Mostafa A

    2012-10-10

    Due to their strong enhancement of scattered light, plasmonic nanoparticles have been utilized for various biological and medical applications. Here, we describe a new technique, Targeted Plasmonic-Enhanced Single-Cell Rayleigh/Raman Spectroscopy, to monitor the molecular changes of any cell-component, such as the nucleus, during the different phases of its full cell cycle by simultaneously recording its Rayleigh images and Raman vibration spectra in real-time. The analysis of the observed Raman DNA and protein peaks allowed the different phases of the cell cycle to be identified. This technique could be used for disease diagnostics and potentially improve our understanding of the molecular mechanisms of cellular functions such as division, death, signaling, and drug action.

  18. The Significance Ultrasonography on the Evaluation of Ovarian Follicular Maturity and Growth

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kab Tae; Kim, Ok Keun; Lee, Seok Hong; Kim, Tae Seon; Kim, Byung Soo [Pusan National University College of Medicine, Busan (Korea, Republic of)

    1987-12-15

    Ovarian follicular diameter was measured using real time ultrasound in 21 hyperstimulated patients from April to September 1986. And we analyzed the relation between the size measured with ultrasonography and maturity observed under the phased microscopy, the correlation between aspirated dominant follicular volume and the dominant follicular volume calculated by the size measured with ultrasonography. Also we experienced the conditions which showed the ultrasonographic finding similar to that of follicle. The results were as follows: 1. The mean follicular diameter increased in a linear fashion from 7 days after LMP (9.4mm+2.8)to the one day before ovum pick up(18.2+2.8). 2. The mean diameter of the most appropriate dominant follicle was 19.08+1.23mm 3. The correlation between the dominant follicular volume measured with ultrasonography and aspirated follicular volume during ovum pick up was highly significant(r=0.94;0<0.001). 4. during follicular growth and maturity monitoring the conditions which misdiagnosed of follicle were simple ovarian cyst(1 case), hydrosalpinx (1 case), endometriosis(1 case), tubo-ovarian abscess(1 case), Hydatid of Morgagni(1 case)

  19. Polycystic ovary syndrome: dynamic contrast-enhanced ovary MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, C. Zuhal E-mail: sunarerdem@yahoo.com; Bayar, Ulku; Erdem, L. Oktay; Barut, Aykut; Gundogdu, Sadi; Kaya, Erdal

    2004-07-01

    Objective: to determine the enhancement behaviour of the ovaries in women with polycystic ovary syndrome (PCOS) by dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging and to compare these data with those of normal ovulating controls. Method: 24 women with PCOS and 12 controls underwent DCE-MR imaging. Dynamic images were acquired before and after injection of a contrast bolus at 30 s and the min of 1, 2, 3, 4 and 5. On postprocessing examination: (i) the ovarian volumes; (ii) the signal intensity value of each ovary per dynamic study; (iii) early-phase enhancement rate; (iv) time to peak enhancement (T{sub p}); and (v) percentage of washout of 5th min were determined. Data of the ovaries of the women with PCOS and controls were compared with Mann-Whitney U-test. Results: the mean values of T{sub p} were found to be significantly lower in women with PCOS than in controls (p<0.05). On the other hand, the mean values of ovarian volume, the early-phase enhancement rate, and percentage of washout of 5th min of ovaries were significantly higher in PCOS patients (p<0.05). Examination of the mean signal intensity-time curve revealed the ovaries in women with PCOS showed a faster and greater enhancement and wash-out. Conclusion: the enhancement behaviour of ovaries of women with PCOS may be significantly different from those of control subjects on DCE-MR imaging examination. In our experience, it is a valuable modality to highlight the vascularization changes in ovarian stroma with PCOS. We believe that improved DCE-MR imaging techniques may also provide us additional parameters in the diagnosis and treatment strategies of PCOS.

  20. Polycystic ovary syndrome: dynamic contrast-enhanced ovary MR imaging

    International Nuclear Information System (INIS)

    Erdem, C. Zuhal; Bayar, Ulku; Erdem, L. Oktay; Barut, Aykut; Gundogdu, Sadi; Kaya, Erdal

    2004-01-01

    Objective: to determine the enhancement behaviour of the ovaries in women with polycystic ovary syndrome (PCOS) by dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging and to compare these data with those of normal ovulating controls. Method: 24 women with PCOS and 12 controls underwent DCE-MR imaging. Dynamic images were acquired before and after injection of a contrast bolus at 30 s and the min of 1, 2, 3, 4 and 5. On postprocessing examination: (i) the ovarian volumes; (ii) the signal intensity value of each ovary per dynamic study; (iii) early-phase enhancement rate; (iv) time to peak enhancement (T p ); and (v) percentage of washout of 5th min were determined. Data of the ovaries of the women with PCOS and controls were compared with Mann-Whitney U-test. Results: the mean values of T p were found to be significantly lower in women with PCOS than in controls (p<0.05). On the other hand, the mean values of ovarian volume, the early-phase enhancement rate, and percentage of washout of 5th min of ovaries were significantly higher in PCOS patients (p<0.05). Examination of the mean signal intensity-time curve revealed the ovaries in women with PCOS showed a faster and greater enhancement and wash-out. Conclusion: the enhancement behaviour of ovaries of women with PCOS may be significantly different from those of control subjects on DCE-MR imaging examination. In our experience, it is a valuable modality to highlight the vascularization changes in ovarian stroma with PCOS. We believe that improved DCE-MR imaging techniques may also provide us additional parameters in the diagnosis and treatment strategies of PCOS

  1. Contrast enhancement in an optical time-domain reflectometer via self-phase modulation compensation by chirped probe pulses

    International Nuclear Information System (INIS)

    Alekseev, A E; Potapov, V T; Vdovenko, V S; Simikin, D E; Gorshkov, B G

    2016-01-01

    In the present paper we propose a novel method for optical time-domain reflectometer (OTDR)–reflectogram contrast enhancement via compensation of nonlinear distortions of propagating probe pulse, which arise due to the self-phase modulation (SPM) effect in optical fiber. The compensation is performed via preliminary frequency modulation (chirp) of the initial probe pulse according to the specific law. As a result the OTDR contrast at some distant predefined fiber point is fully restored to the value of non-distorted probe pulse at the beginning of the fiber line. As a result, the performance of the phase OTDR increases. The point of full SPM compensation could be shifted to any other point of the fiber line via preliminary frequency modulation index change. The feasibility of the proposed method is theoretically proved and experimentally demonstrated. (paper)

  2. Real-time tomosynthesis for radiation therapy guidance.

    Science.gov (United States)

    Hsieh, Scott S; Ng, Lydia W

    2017-11-01

    Fluoroscopy has been a tool of choice for monitoring treatments or interventions because of its extremely fast imaging times. However, the contrast obtained in fluoroscopy may be insufficient for certain clinical applications. In stereotactic ablative radiation therapy of the lung, fluoroscopy often lacks sufficient contrast for gating treatment. The purpose of this work is to describe and assess a real-time tomosynthesis design that can produce sufficient contrast for guidance of lung tumor treatment within a small field of view. Previous tomosynthesis designs in radiation oncology have temporal resolution on the order of seconds. The proposed system design uses parallel acquisition of multiple frames by simultaneously illuminating the field of view with multiple sources, enabling a temporal resolution of up to 30 frames per second. For a small field of view, a single flat-panel detector could be used if different sectors of the detector are assigned to specific sources. Simulated images were generated by forward projection of existing clinical datasets. The authors varied the number of tubes and the power of each tube in order to determine the impact on tumor visualization. Visualization of the tumor was much clearer in tomosynthesis than in fluoroscopy. Contrast generally improved with the number of sources used, and a minimum of four sources should be used. The high contrast of the lung allows very low system power, and in most cases, less than 1 mA was needed. More power is required in the lateral direction than the AP direction. The proposed system produces images adequate for real-time guidance of radiation therapy. The additional hardware requirements are modest, and the system is capable of imaging at high frame rates and low dose. Further development, including a prototype system and a dosimetry study, is needed to further evaluate the feasibility of this device for radiation therapy guidance. © 2017 American Association of Physicists in Medicine.

  3. Musculoskeletal ultrasonography in children

    International Nuclear Information System (INIS)

    Teo, E.-L.H.; Strouse, P.J.; Chhem, R.K.

    2002-01-01

    With the development of high-resolution ultrasound transducers, the role of ultrasonography (US) in evaluating the musculoskeletal system has increased. It is now possible to obtain detailed images of bones and soft-tissue structures that were previously unattainable. The advantages of US, when compared with other imaging modalities, are many. It is less expensive than magnetic resonance imaging (MRI) and computed tomography (CT). It does not expose the patient to ionizing radiation, so US examinations can be repeated without harm to the patient. Furthermore, US is performed in real-time, making it possible to assess the musculoskeletal system dynamically, in multiple planes and with contralateral comparison. In experienced hands, US is a quick, noninvasive and cost-effective way to assess the musculoskeletal system in children. It is used to evaluate soft-tissue masses, joint swelling, infections, lesions involving the chest and abdominal walls, bones, muscles and clubfoot deformity and to locate any foreign bodies. (author)

  4. Post-traumatic contrast enhancing brain lesion

    International Nuclear Information System (INIS)

    Kim, Dae Jung; Kim, Hyun Sook; Jeong, Min Sun; Kim, Deok Ryeong; Cho, Young Kwon; Choi, Yun Sun

    2014-01-01

    Only a few studies have been reported on the MR contrast enhancement and the apparent diffusion coefficient (ADC) findings of the post-traumatic lesion of the brain. We report a case of the venous ischemia in the left frontal lobe observed in the MRI obtained one day after the incidence of trauma. Considering the presented slight increase in the ADC, the vasogenic edema was thought to be the major mechanism of the venous ischemia and excitotoxic injury. In spite of a slight increase in the ADC, the hyperintensity in the diffusion weighted imaging and contrast-enhanced areas eventually changed into hemorrhagic lesions.

  5. Post-traumatic contrast enhancing brain lesion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Jung; Kim, Hyun Sook; Jeong, Min Sun; Kim, Deok Ryeong; Cho, Young Kwon; Choi, Yun Sun [Eulji Hospital, Eulji University College of Medicine, Seoul (Korea, Republic of)

    2014-10-15

    Only a few studies have been reported on the MR contrast enhancement and the apparent diffusion coefficient (ADC) findings of the post-traumatic lesion of the brain. We report a case of the venous ischemia in the left frontal lobe observed in the MRI obtained one day after the incidence of trauma. Considering the presented slight increase in the ADC, the vasogenic edema was thought to be the major mechanism of the venous ischemia and excitotoxic injury. In spite of a slight increase in the ADC, the hyperintensity in the diffusion weighted imaging and contrast-enhanced areas eventually changed into hemorrhagic lesions.

  6. Diagnostic Accuracy of Detecting Hashimoto's Thyroiditis in Thyroid Cancer Patients Who Underwent Thyroid Surgery: Comparison of Ultrasonography, Positron Emission Tomography/CT, Contrast Enhanced CT, and Anti-Thyroid Antibody

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Gyun; Lee, Tae Hyun; Park, Dong Hee; Nam, Sang Been [Dept. of Radiology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2012-11-15

    To compare the diagnostic accuracy of ultrasonography (US), F18-fluorodeoxyglucose positron emission tomography/CT (PET/CT), contrast enhanced CT (CECT), serum anti-thyroid antibody for detecting Hashimoto's thyroiditis in thyroid cancer patients who underwent neck surgery. A total of 150 patients with suspicious for thyroid cancer, who had previously undergone US guided needle aspiration of thyroid, were evaluated with the use of US, PET/CT, CECT and serum anti-thyroid antibody. The four studies were performed within two months before neck surgery. Hashimoto's thyroiditis was confirmed by histopathological results. The diagnostic accuracy of US, PET/CT, CECT and serum anti-thyroid antibody were calculated statistically. Hashimoto's thyroiditis was diagnosed in 51 out of the 150 patients, following neck surgery. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of US were 76.5%, 92.9%, 84.8%, 88.5%, and 87.3%, respectively. The corresponding values of PET/CT were 37.3%, 96.0%, 82.6%, 74.8%, and 76.0%, and CECT were 62.7%, 89.9%, 76.2%, 82.4%, and 80.7%, and serum anti-thyroid antibody level were 90.2%, 93.9%, 88.5%, 94.9%, and 92.7%, respectively. McNemar test revealed significant difference among PET/CT and others, but no significant differences among US, CECT and serum anti-thyroid antibody. Overall, serum anti-thyroid antibody showed most accurate diagnostic performance. In detecting Hashimoto's thyroiditis, serum anti-thyroid antibody showed higher diagnostic accuracy than others. US also showed relatively high diagnostic accuracy.

  7. Contrast-enhanced fluorodeoxyglucose positron emission tomography/contrast-enhanced computed tomography in mediastinal T-cell lymphoma with superior vena cava syndrome

    International Nuclear Information System (INIS)

    Santhosh, Sampath; Gorla, Arun Kumar Reddy; Bhattacharya, Anish; Varma, Subhash Chander; Mittal, Bhagwant Rai

    2016-01-01

    Positron emission tomography-computed tomography (PET/CT) is a routine investigation for the staging of lymphomas. Contrast-enhanced computed tomography is mandatory whenever parenchymal lesions, especially in the liver and spleen are suspected. We report a rare case of primary mediastinal T-cell lymphoma evaluated with contrast-enhanced PET/CT that showed features of superior vena cava syndrome

  8. Evaluation of paraclinoid aneurysm by using contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Tsuboi, Toshiyuki; Takahashi, Kazuya; Date, Isao; Mandai, Shinya; Kinugasa, Kazushi; Nishimoto, Akira

    2004-01-01

    Juxta-dural ring aneurysms of the internal carotid artery have different clinical courses and risks of subarachnoid hemorrhage (SAH) depending upon their positions in the intradural or extradural spaces. The goal of this study was to localize such aneurysms using contrast enhanced-MR Angiography (CE-MRA). CE-MRA studies were performed in 18 patients with juxta-dural ring aneurysms using three-dimensional time-of-flight spoiled gradient-recalled acquisition in the steady state (3D-TOF-SPGR) sequence. Imaging parameters were as follows: 33/3.4/1 (repetition time/echo time/number of excitation (TR/TE/NEX)), flip angle 25 deg, 256 x 192 matrix, 0.8-mm slice thickness, 60 sections in total (one slab), 180-mm field of view, with no magnetization transfer contrast (MTC), superior saturation (S sat) pulse, total imaging time 6 minutes 53 seconds. We evaluated both the source images of CE-MRA and multiplanar reconstruction (MPR) images. When the hyperintensity of the aneurysm was located within the hyperintensity of the contrast-enhanced cavernous sinus, we diagnosed the lesion as an intracavernous, ''extradural'' aneurysm. In addition, we compared CE-MRA with operative findings. Seven patients out of 18 were treated surgically. In all, MRI findings corresponded well with the operative findings. We believe CE-MRA and its MPR images using 3D-TOF-SPGR sequence is a useful technique to evaluate juxta-dural ring aneurysms. (author)

  9. Real-time tracking of dissociation of hyperpolarized 89Y-DTPA: a model for degradation of open-chain Gd3+ MRI contrast agents

    Science.gov (United States)

    Ferguson, Sarah; Niedbalski, Peter; Parish, Christopher; Kiswandhi, Andhika; Kovacs, Zoltan; Lumata, Lloyd

    Gadolinium (Gd) complexes are widely used relaxation-based clinical contrast agents in magnetic resonance imaging (MRI). Gd-based MRI contrast agents with open-chain ligand such as Gd-DTPA, commercially known as magnevist, are less stable compared to Gd complexes with macrocyclic ligands such as GdDOTA (Dotarem). The dissociation of Gd-DPTA into Gd ion and DTPA ligand under certain biological conditions such as high zinc levels can potentially cause kidney damage. Since Gd is paramagnetic, direct NMR detection of the Gd-DTPA dissociation is quite challenging due to ultra-short relaxation times. In this work, we have investigated Y-DTPA as a model for Gd-DPTA dissociation under high zinc content solutions. Using dissolution dynamic nuclear polarization (DNP), the 89Y NMR signal is amplified by several thousand-fold. Due to the the relatively long T1 relaxation time of 89Y which translates to hyperpolarization lifetime of several minutes, the dissociation of Y-DTPA can be tracked in real-time by hyperpolarized 89Y NMR spectroscopy. Dissociation kinetic rates and implications on the degradation of open-chain Gd3+ MRI contrast agents will be discussed. This work was supported by the U.S. Department of Defense Award Number W81XWH-14-1-0048 and by the Robert A. Welch Foundation research Grant Number AT-1877.

  10. Influence of hyperosmotic agent (glycerol) in contrast enhancement

    International Nuclear Information System (INIS)

    Moriyama, Takashi; Suzuki, Shigeharu; Nakaoka, Tsutomu

    1981-01-01

    For getting a better contrast enhancement (CE) of computed tomography (CT) in brain tumors, we tried to increase the extravascular iodine concentration. A vailing ourselves of the period of returning water following intravenously administered glycerol, a drip injection of the contrast medium gave a better CE effect than the usual CE. In two benign gliomas, CE with glycerol was much better than CE without glycerol, and in two malignant gliomas and two metastatic tumors, CE with glycerol was better, but not so much better as with the benign tumors. In general, the CE effect in primary brain tumors showed a decreasing pattern, whereas in metastatic brain tumors the best time was 60 minutes after the injection of the contrast material (increasing and decreasing pattern), suggesting an increase in the extravascular iodine and a severe failure of the blood brain barrier. Two cystic malignant gliomas allowed the intravenously injected contrast medium to enter the cysts. It appears that the contrast medium passes through and/or is secreted from the wall of the cyst. (author)

  11. Contrast-enhanced color Doppler ultrasound characteristics in hypervascular breast tumors: comparison with MRI

    International Nuclear Information System (INIS)

    Alamo, L.; Fischer, U.

    2001-01-01

    The aim of this study was to evaluate the accuracy of contrast-enhanced color Doppler ultrasound (CE-US) in comparison with contrast-enhanced MR imaging (CE-MRI) in the discrimination of hypervascularized breast tumors. An additional CE-US of the breast was preoperatively performed in 40 patients with a hypervascular breast lesion detected on CE-MRI. The presence of blood flow signals and the morphological characteristics of the vessels in the breast lesions were evaluated pre- and post-contrast administration, as well as the dynamic aspects of the Doppler signal, including time interval to maximum signal enhancement and persistence of the signal enhancement. Twenty-three carcinomas and 17 fibroadenomas were explored. Considering initial signal enhancement > 100 % after the administration of contrast material as a criterion suggesting malignancy, CE-MRI showed a sensitivity of 100 % and a specificity of 76.5 % in the detection of malignant breast tumors. Color Doppler signals were consistently demonstrated in all carcinomas and in 68.7 % of fibroadenomas after the administration of Levovist, with CE-US showing a sensitivity of 95.6 % and a specificity of 5.9 %. Neither the mean number of vessels per tumor, nor the location of vessels, the time to maximum increase of the Doppler signal or the persistence of signal enhancement showed significant differences between benign and malignant lesions. Additional CE-US does not increase the low specificity of MRI in patients with hypervascularized breast tumors. (orig.)

  12. Contrast Enhanced Spectral Mammography: A Review.

    Science.gov (United States)

    Patel, Bhavika K; Lobbes, M B I; Lewin, John

    2018-02-01

    Contrast-enhanced spectral mammography (CESM) provides low-energy 2D mammographic images comparable to standard digital mammography and a post-contrast recombined image to assess tumor neovascularity similar to magnetic resonance imaging (MRI). The utilization of CESM in the United States is currently low but could increase rapidly given many potential indications for clinical use. This article discusses historical background and literature review of indications and diagnostic accuracy of CESM to date. CESM is a growing technique for breast cancer detection and diagnosis that has levels of sensitivity and specificity on par with contrast-enhanced breast MRI. Because of its similar performance and ease of implementation, CESM is being adopted for multiple indications previously reserved for MRI, such as problem-solving, disease extent in newly diagnosed patients, and evaluating the treatment response of neoadjuvant chemotherapy. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Real-time statistical quality control and ARM

    International Nuclear Information System (INIS)

    Blough, D.K.

    1992-05-01

    An important component of the Atmospheric Radiation Measurement (ARM) Program is real-time quality control of data obtained from meteorological instruments. It is the goal of the ARM program to enhance the predictive capabilities of global circulation models by incorporating in them more detailed information on the radiative characteristics of the earth's atmosphere. To this end, a number of Cloud and Radiation Testbeds (CART's) will be built at various locations worldwide. Each CART will consist of an array of instruments designed to collect radiative data. The large amount of data obtained from these instruments necessitates real-time processing in order to flag outliers and possible instrument malfunction. The Bayesian dynamic linear model (DLM) proves to be an effective way of monitoring the time series data which each instrument generates. It provides a flexible yet powerful approach to detecting in real-time sudden shifts in a non-stationary multivariate time series. An application of these techniques to data arising from a remote sensing instrument to be used in the CART is provided. Using real data from a wind profiler, the ability of the DLM to detect outliers is studied. 5 refs

  14. Contrast-enhanced magnetic resonance imaging for the detection of acute haemorrhagic necrotizing pancreatitis

    International Nuclear Information System (INIS)

    Piironen, A.; Kivisaari, R.; Pitkaeranta, P.; Poutanen, V.P.; Laippala, P.; Laurila, P.; Kivisaari, L.

    1997-01-01

    Eleven piglets with haemorrhagic necrotizing pancreatitis and nine piglets with oedematous pancreatitis were imaged using a multi-breath-hold TurboFLASH (TR 6.5 ms, TE 3 ms, TI 300 ms, flip angle 8 , three slices) pre-excited T1-weighted sequence with an IV bolus injection of gadopentetate dimeglumine (Gd-DTPA, 0.3 mmol/kg) as a contrast agent to show dynamic contrast enhancement of the pancreas by MRI. All piglets were imaged according to the same protocol before inducing the disease. Following the IV Gd-DTPA bolus, time-enhancement curve of the pancreas during haemorrhagic necrotizing pancreatitis was significantly lower than during oedematous pancreatitis. The enhancement curves for the healthy piglets and piglets with oedematous pancreatitis did not differ significantly. Each piglet served as its own control. Because the results of this initial study are similar to those obtained with contrast-enhanced CT, we conclude that our results may encourage further clinical trials, and contrast-enhanced dynamic MRI may be an alternative to the established method of CT for diagnosing acute haemorrhagic necrotizing pancreatitis. (orig.). With 3 figs

  15. Adaptive digital image processing in real time: First clinical experiences

    International Nuclear Information System (INIS)

    Andre, M.P.; Baily, N.A.; Hier, R.G.; Edwards, D.K.; Tainer, L.B.; Sartoris, D.J.

    1986-01-01

    The promise of computer image processing has generally not been realized in radiology, partly because the methods advanced to date have been expensive, time-consuming, or inconvenient for clinical use. The authors describe a low-cost system which performs complex image processing operations on-line at video rates. The method uses a combination of unsharp mask subtraction (for low-frequency suppression) and statistical differencing (which adjusts the gain at each point of the image on the basis of its variation from a local mean). The operator interactively adjusts aperture size, contrast gain, background subtraction, and spatial noise reduction. The system is being evaluated for on-line fluoroscopic enhancement, for which phantom measurements and clinical results, including lithotripsy, are presented. When used with a video camera, postprocessing of radiographs was advantageous in a variety of studies, including neonatal chest studies. Real-time speed allows use of the system in the reading room as a ''variable view box.''

  16. Irregular vascular pattern by contrast-enhanced ultrasonography and high serum Lens culinaris agglutinin-reactive fraction of alpha-fetoprotein level predict poor outcome after successful radiofrequency ablation in patients with early-stage hepatocellular carcinoma.

    Science.gov (United States)

    Takada, Hitomi; Tsuchiya, Kaoru; Yasui, Yutaka; Nakakuki, Natsuko; Tamaki, Nobuharu; Suzuki, Shoko; Nakanishi, Hiroyuki; Itakura, Jun; Takahashi, Yuka; Kurosaki, Masayuki; Asahina, Yasuhiro; Enomoto, Nobuyuki; Izumi, Namiki

    2016-11-01

    Radiofrequency ablation (RFA) is considered the most effective treatment for early-stage hepatocellular carcinoma (HCC) patients unsuitable for resection. However, poor outcome after RFA has occasionally been reported worldwide. To predict such an outcome, we investigated imaging findings using contrast-enhanced ultrasonography (CEUS) with Sonazoid and serum tumor markers before RFA. This study included 176 early-stage HCC patients who had initially achieved successful RFA. Patients were examined using CEUS; their levels of alpha-fetoprotein (AFP), Lens culinaris agglutinin-reactive fraction of AFP (AFP-L3), and des-gamma-carboxy prothrombin before RFA were measured. Sonazoid provided parenchyma-specific contrast imaging and facilitated tumor vascular architecture imaging through maximum intensity projection (MIP). Kaplan-Meier analysis examined cumulative rates of local tumor progression, intrasubsegmental recurrence, and survival; factors associated with these were determined with Cox proportional hazards analysis. Local tumor progression (n = 15), intrasubsegmental recurrence (n = 46), and death (n = 18) were observed. Irregular pattern in MIP classification and serum AFP-L3 level (>10%) before RFA were identified as independent risk factors for local tumor progression and intrasubsegmental recurrence. These two factors were independently associated with poor survival after RFA (irregular pattern in MIP: hazard ratio, (HR) = 8.26; 95% confidence interval, (CI) = 2.24-30.3; P = 0.002 and AFP-L3 > 10%: HR = 2.94; 95% CI = 1.09-7.94; P = 0.033). Irregular MIP pattern by CEUS and high level of serum AFP-L3 were independent risk factors for poor outcome after successful RFA. The Patients with these findings should be considered as special high-risk group in early-stage HCC. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  17. Detection of infusate leakage in the brain using real-time imaging of convection-enhanced delivery.

    Science.gov (United States)

    Varenika, Vanja; Dickinson, Peter; Bringas, John; LeCouteur, Richard; Higgins, Robert; Park, John; Fiandaca, Massimo; Berger, Mitchel; Sampson, John; Bankiewicz, Krystof

    2008-11-01

    The authors have shown that convection-enhanced delivery (CED) of gadoteridol-loaded liposomes (GDLs) into different regions of normal monkey brain results in predictable, widespread distribution of this tracking agent as detected by real-time MR imaging. They also have found that this tracking technique allows monitoring of the distribution of similar nanosized agents such as therapeutic liposomes and viral vectors. A limitation of this procedure is the unexpected leakage of liposomes out of targeted parenchyma or malignancies into sulci and ventricles. The aim of the present study was to evaluate the efficacy of CED after the onset of these types of leakage. The authors documented this phenomenon in a study of 5 nonhuman primates and 7 canines, comprising 54 CED infusion sessions. Approximately 20% of these infusions resulted in leakage into cerebral ventricles or sulci. All of the infusions and leakage events were monitored with real-time MR imaging. The authors created volume-distributed versus volume-infused graphs for each infusion session. These graphs revealed the rate of distribution of GDL over the course of each infusion and allowed the authors to evaluate the progress of CED before and after leakage. The distribution of therapeutics within the target structure ceased to increase or resulted in significant attenuation after the onset of leakage. An analysis of the cases in this study revealed that leakage undermines the efficacy of CED. These findings reiterate the importance of real-time MR imaging visualization during CED to ensure an accurate, robust distribution of therapeutic agents.

  18. Generalized image contrast enhancement technique based on the Heinemann contrast discrimination model

    Science.gov (United States)

    Liu, Hong; Nodine, Calvin F.

    1996-07-01

    This paper presents a generalized image contrast enhancement technique, which equalizes the perceived brightness distribution based on the Heinemann contrast discrimination model. It is based on the mathematically proven existence of a unique solution to a nonlinear equation, and is formulated with easily tunable parameters. The model uses a two-step log-log representation of luminance contrast between targets and surround in a luminous background setting. The algorithm consists of two nonlinear gray scale mapping functions that have seven parameters, two of which are adjustable Heinemann constants. Another parameter is the background gray level. The remaining four parameters are nonlinear functions of the gray-level distribution of the given image, and can be uniquely determined once the previous three are set. Tests have been carried out to demonstrate the effectiveness of the algorithm for increasing the overall contrast of radiology images. The traditional histogram equalization can be reinterpreted as an image enhancement technique based on the knowledge of human contrast perception. In fact, it is a special case of the proposed algorithm.

  19. Optical tracking of contrast medium bolus to optimize bolus shape and timing in dynamic computed tomography

    International Nuclear Information System (INIS)

    Eisa, Fabian; Brauweiler, Robert; Peetz, Alexander; Hupfer, Martin; Nowak, Tristan; Kalender, Willi A

    2012-01-01

    One of the biggest challenges in dynamic contrast-enhanced CT is the optimal synchronization of scan start and duration with contrast medium administration in order to optimize image contrast and to reduce the amount of contrast medium. We present a new optically based approach, which was developed to investigate and optimize bolus timing and shape. The time-concentration curve of an intravenously injected test bolus of a dye is measured in peripheral vessels with an optical sensor prior to the diagnostic CT scan. The curves can be used to assess bolus shapes as a function of injection protocols and to determine contrast medium arrival times. Preliminary results for phantom and animal experiments showed the expected linear behavior between dye concentration and absorption. The kinetics of the dye was compared to iodinated contrast medium and was found to be in good agreement. The contrast enhancement curves were reliably detected in three mice with individual bolus shapes and delay times of 2.1, 3.5 and 6.1 s, respectively. The optical sensor appears to be a promising approach to optimize injection protocols and contrast enhancement timing and is applicable to all modalities without implying any additional radiation dose. Clinical tests are still necessary. (note)

  20. Synergistic enhancement of iron oxide nanoparticle and gadolinium for dual-contrast MRI

    International Nuclear Information System (INIS)

    Zhang, Fan; Huang, Xinglu; Qian, Chunqi; Zhu, Lei; Hida, Naoki; Niu, Gang; Chen, Xiaoyuan

    2012-01-01

    Highlights: ► MR contrast agents exert influence on T 1 or T 2 relaxation time of the surrounding tissue. ► Combined use of iron oxide and Gd-DTPA can improve the sensitivity/specificity of lesion detection. ► Dual contrast MRI enhances the delineation of tumor borders and small lesions. ► The effect of DC-MRI can come from the high paramagnetic susceptibility of Gd 3+ . ► The effect of DC-MRI can also come from the distinct pharmacokinetic distribution of SPIO and Gd-DTPA. -- Abstract: Purpose: The use of MR contrast agents allows accurate diagnosis by exerting an influence on the longitudinal (T 1 ) or transverse (T 2 ) relaxation time of the surrounding tissue. In this study, we combined the use of iron oxide (IO) particles and nonspecific extracellular gadolinium chelate (Gd) in order to further improve the sensitivity and specificity of lesion detection. Procedures: With a 7-Tesla scanner, pre-contrasted, IO-enhanced and dual contrast agent enhanced MRIs were performed in phantom, normal animals, and animal models of lymph node tumor metastases and orthotopic brain tumor. For the dual-contrast (DC) MRI, we focused on the evaluation of T 2 weighted DC MRI with IO administered first, then followed by the injection of a bolus of gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA). Results: Based on the C/N ratios and MRI relaxometry, the synergistic effect of coordinated administration of Gd-DTPA and IO was observed and confirmed in phantom, normal liver and tumor models. At 30 min after administration of Feridex, Gd-DTPA further decreased T 2 relaxation in liver immediately after the injection. Additional administration of Gd-DTPA also immediately increased the signal contrast between tumor and brain parenchyma and maximized the C/N ratio to −4.12 ± 0.71. Dual contrast MRI also enhanced the delineation of tumor borders and small lesions. Conclusions: DC-MRI will be helpful to improve diagnostic accuracy and decrease the threshold size for

  1. Diagnostic Accuracy of Dynamic Contrast Enhanced Magnetic Resonance Imaging in Characterizing Lung Masses

    Science.gov (United States)

    Inan, Nagihan; Arslan, Arzu; Donmez, Muhammed; Sarisoy, Hasan Tahsin

    2016-01-01

    Background Imaging plays a critical role not only in the detection, but also in the characterization of lung masses as benign or malignant. Objectives To determine the diagnostic accuracy of dynamic magnetic resonance imaging (MRI) in the differential diagnosis of benign and malignant lung masses. Patients and Methods Ninety-four masses were included in this prospective study. Five dynamic series of T1-weighted spoiled gradient echo (FFE) images were obtained, followed by a T1-weighted FFE sequence in the late phase (5th minutes). Contrast enhancement patterns in the early (25th second) and late (5th minute) phase images were evaluated. For the quantitative evaluation, signal intensity (SI)-time curves were obtained and the maximum relative enhancement, wash-in rate, and time-to-peak enhancement of masses in both groups were calculated. Results The early phase contrast enhancement patterns were homogeneous in 78.2% of the benign masses, while heterogeneous in 74.4% of the malignant tumors. On the late phase images, 70.8% of the benign masses showed homogeneous enhancement, while most of the malignant masses showed heterogeneous enhancement (82.4%). During the first pass, the maximum relative enhancement and wash-in rate values of malignant masses were significantly higher than those of the benign masses (P = 0.03 and 0.04, respectively). The cutoff value at 15% yielded a sensitivity of 85.4%, specificity of 61.2%, and positive predictive value of 68.7% for the maximum relative enhancement. Conclusion Contrast enhancement patterns and SI-time curve analysis of MRI are helpful in the differential diagnosis of benign and malignant lung masses. PMID:27703654

  2. Sentinel node detection in melanomas using contrast-enhanced ultrasound

    DEFF Research Database (Denmark)

    Nielsen, K. Rue; Klyver, H.; Chakera, A. Hougaard

    2009-01-01

    in humans. PURPOSE: To investigate the possible use of CEUS in detecting SN in patients with malignant melanomas (MM), and to improve the method by using different concentrations of contrast agent and various positions of the extremity. MATERIAL AND METHODS: Ten patients with MM on an extremity and one...... healthy volunteer were included. One milliliter of a contrast agent (Sonovue; Bracco, Milan, Italy) was injected subcutaneously on both sides of the scar from the excised tumor. Contrast-enhanced lymph channels and lymph nodes (LNs) were searched for using low-mechanical-index CEUS and by stimulated...... tissue damage, as the contrast agent was not registered for subcutaneous administration. RESULTS: In one patient, two contrast-enhanced inguinal LNs were visualized by CEUS, corresponding to two inguinal SNs found by scintigraphic imaging. No contrast-enhanced lymph channels or LNs were visualized in any...

  3. Can Real-Time Data Also Be Climate Quality?

    Science.gov (United States)

    Brewer, M.; Wentz, F. J.

    2015-12-01

    GMI, AMSR-2 and WindSat herald a new era of highly accurate and timely microwave data products. Traditionally, there has been a large divide between real-time and re-analysis data products. What if these completely separate processing systems could be merged? Through advanced modeling and physically based algorithms, Remote Sensing Systems (RSS) has narrowed the gap between real-time and research-quality. Satellite microwave ocean products have proven useful for a wide array of timely Earth science applications. Through cloud SST capabilities have enormously benefited tropical cyclone forecasting and day to day fisheries management, to name a few. Oceanic wind vectors enhance operational safety of shipping and recreational boating. Atmospheric rivers are of import to many human endeavors, as are cloud cover and knowledge of precipitation events. Some activities benefit from both climate and real-time operational data used in conjunction. RSS has been consistently improving microwave Earth Science Data Records (ESDRs) for several decades, while making near real-time data publicly available for semi-operational use. These data streams have often been produced in 2 stages: near real-time, followed by research quality final files. Over the years, we have seen this time delay shrink from months or weeks to mere hours. As well, we have seen the quality of near real-time data improve to the point where the distinction starts to blur. We continue to work towards better and faster RFI filtering, adaptive algorithms and improved real-time validation statistics for earlier detection of problems. Can it be possible to produce climate quality data in real-time, and what would the advantages be? We will try to answer these questions…

  4. Prognostic value of contrast-enhanced MR mammography in patients with breast cancer.

    Science.gov (United States)

    Fischer, U; Kopka, L; Brinck, U; Korabiowska, M; Schauer, A; Grabbe, E

    1997-01-01

    The objective of this study was to evaluate the prognostic value of contrast-enhanced MR mammography in patients with breast cancer. A total of 190 patients with breast cancer (37 noninvasive carcinomas, 153 invasive carcinomas) underwent dynamic contrast-enhanced MR mammography preoperatively. Using 1.5-T unit, T1-weighted sequences (2D FLASH) were obtained repeatedly one time before and five times after IV administration of 0.1 mmol gadopentetate-dimeglumine per kilogram body weight. The findings on MR imaging were correlated with histopathologically defined prognostic factors (histological type, tumor size, tumor grading, metastasis in lymph nodes). In addition, immunohistochemically defined prognostic factors (c-erbB-1, c-erbB-2, p53, Ki-67) were correlated with the signal increase on MR mammogram in 40 patients. There was no significant correlation between the findings on MR mammography and the histopathological type of carcinoma, the grading, and the lymphonodular status. Noninvasive carcinomas showed a higher rate of moderate (38 %) or low (27 %) enhancement on MR imaging than invasive carcinomas (6 and 3 %). The results on MR mammography and the results of immunohistochemical stainings did not correlate significantly. Noninvasive carcinomas showed significantly lower enhancement than invasive carcinomas. However, the signal behavior of contrast-enhanced MR mammography is not related to established histopathological prognostic parameters as subtyping, grading, nodal status, and the expression of certain oncogenes/tumor suppressor genes.

  5. Ultrasonography in the evaluation of tongue and mouth pathology

    International Nuclear Information System (INIS)

    Lee, Chan Wha; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Lee, Jong Tae; Hong, Won Pyo; Park, Hyung Sik

    1991-01-01

    The evaluation of the tongue and mouth floor using the CT scan can be limited due to dental artifacts. Because the therapeutic plan depends on the nature and the cancer staging of lesions, it is essential to obtain accurate evaluation of lesions. In this study are explored the of Ultrasonography for the evaluation of tongue and mouth floor pathology. We have obtained ultrasonograms in 20 patients who had benign and malignant lesions in the tongue and mouth floor. Comparative analysis was made on 15 patients who underwent both CT and ultrasonography. We used the bimanual compression technique and the phonation technique during real-time scanning. Out of 15 cases, six had tongue cancer, and seven of them had cancer of the mouth floor. The other cases included a ranula, a dermoid cyst, a Ludwig's angina, and abscess of salivary gland, and one care with stones of the submandibular gland. All the benign and malignant masses appeared hypoechoic. Even though the lesions of tongue and mouth floor could not be evaluated by CT scan due to dental artifacts and extremely small size in 5 cases, ultrasonogram using the bimanual compression technique demonstrated good localization of the lesion, and also was greatly helpful in visualizing the invasion of the surrounding structures. Ultrasonography of the tongue and mouth floor proved to be superior to the CT scan not only in delineating the size and extent of the primary lesion, but also in visualizing invasion of surrounding structures

  6. Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantification

    International Nuclear Information System (INIS)

    Heussel, C.P.; Kappes, J.; Hantusch, R.; Hartlieb, S.; Weinheimer, O.; Kauczor, H.-U.; Eberhardt, R.

    2010-01-01

    Systemic, interventional and surgical treatments have gone new ways in treatment of emphysema. For longitudinal therapy monitoring and as end-points for clinical trials, quantification of the disease is necessary. Sensitive, easy to measure, as well as stable and reproducible parameters have to be characterized. One parameter that might affect emphysema quantification is IV contrast enhancement, which might also be indicated. Whether or not the contrast enhanced scan is also suited for emphysema quantification or an additional scan is necessary, a retrospective analysis of 12 adult patients undergoing clinically indicated both, a non-enhanced and enhanced thin section MSCT within a week (median 0 days, range 0-4 days) was done. The in-house YACTA software was used for automatic quantification of lung and emphysema volume, emphysema index, mean lung density, and 5th, 10th, 15th percentile. After IV contrast administration, the median CT derived lung volume decreased mild by 1.1%, while median emphysema volume decreased by relevant 11%. This results in a decrease of median emphysema index by 9%. The median lung density (15th percentile) increased after contrast application by 18 HU (9 HU). CT quantification delivers emphysema values that are clearly affected by IV contrast application. The detected changes after contrast application show the results of higher density in the lung parenchyma. Therefore the amount of quantified emphysema is reduced and the lung density increased after contrast enhancement. In longitudinal analyses, non-enhanced scans should be the reference, while enhanced scans cannot be used.

  7. High contrast enhancement aspect of dynamic computed tomography with arterial infusion - DCT-AI

    International Nuclear Information System (INIS)

    Kato, Seishi; Iwasaki, Naoya; Matsumura, Yoshimitsu; Kuramae, Shigeru; Mishiro, Tadashi

    1983-01-01

    Dynamic computed tomography was performed on 112 cases possibly having hepatic tumors with intraarterial infusion of undiluted contrast into a selectively placed catheter following angiographies. Our dynamic program could evaluate not only early phase of enhancement but also late phase up to 120 sec. Reconstructed views from early scans and magnified views were very useful to evaluate minute sequential changes. Hepatic masses less than 5 cm in size were found in thirty-one cases. Patterns of tumor enhancement and time-density curves have been analysed to correlate them with histology. Four types of tumor enhancement were noted: (1) homogeneous (2) patchy (3) mottled (4) ringed. Characteristic changes were observed in hepatocellular carcinoma - HCC - (mostly mottled) and haemangioma (mostly patchy). The former was divided in two groups reflecting the cellular maturity. The metastatic tumor could be enhanced in a ringed form with dendritic pattern of supplying vascularities in some cases. To support the use of undiluted contrast and to investigate the diagnostic efficacy of high contrast enhancement, experiments were performed by taking transaxial views of an acrylic phantom immersed in different concentrations of contrast. Analysis of CT images taken at different HU values ranging from 0 to 450 demonstrated that the higher the concentration of contrast, the better the spatial resolution was. Also larger magnification could be expected by using higher concentration of contrast. Although our Dynamic Computed Tomography with Arterial Infusion of Contrast still has drawbacks and limited indications, we advocate it as a better way of enhancement to detect and evaluate the hepatic masses, which sometimes elude the examiner's grasp with conventional way of enhancement. (author)

  8. Fast and robust wavelet-based dynamic range compression and contrast enhancement model with color restoration

    Science.gov (United States)

    Unaldi, Numan; Asari, Vijayan K.; Rahman, Zia-ur

    2009-05-01

    Recently we proposed a wavelet-based dynamic range compression algorithm to improve the visual quality of digital images captured from high dynamic range scenes with non-uniform lighting conditions. The fast image enhancement algorithm that provides dynamic range compression, while preserving the local contrast and tonal rendition, is also a good candidate for real time video processing applications. Although the colors of the enhanced images produced by the proposed algorithm are consistent with the colors of the original image, the proposed algorithm fails to produce color constant results for some "pathological" scenes that have very strong spectral characteristics in a single band. The linear color restoration process is the main reason for this drawback. Hence, a different approach is required for the final color restoration process. In this paper the latest version of the proposed algorithm, which deals with this issue is presented. The results obtained by applying the algorithm to numerous natural images show strong robustness and high image quality.

  9. Performance evaluation of real time radiographic systems

    International Nuclear Information System (INIS)

    Venkatraman, B.; Saravanan, S.; Jayakumar, T.; Kalyanasundaram, P.; Baldev Raj

    1996-01-01

    The Real Time Radiography (RTR) system can be studied completely by knowing the modulation transfer function (MTF) of the whole system. The MTF curve is a special form of contrast/detail-size diagram in which the image contrast is plotted against the spatial frequency of a test object measured in line-pairs per millimetre (lp/mm). MTF curves are widely used to measure the characteristics of optical equipment, particularly for assessing the contribution of individual items in a complex imaging transfer system. Codes of practice indicate that the image intensifier systems should be checked periodically to assess its performance through the use of MTF curves and step wedges for contrast ratio. Authors, instead, suggest the use of performance curves which are simple to obtain and can be easily interpreted by radiographers. (author)

  10. Segmentation methods for breast vasculature in dual-energy contrast-enhanced digital breast tomosynthesis

    Science.gov (United States)

    Lau, Kristen C.; Lee, Hyo Min; Singh, Tanushriya; Maidment, Andrew D. A.

    2015-03-01

    Dual-energy contrast-enhanced digital breast tomosynthesis (DE CE-DBT) uses an iodinated contrast agent to image the three-dimensional breast vasculature. The University of Pennsylvania has an ongoing DE CE-DBT clinical study in patients with known breast cancers. The breast is compressed continuously and imaged at four time points (1 pre-contrast; 3 post-contrast). DE images are obtained by a weighted logarithmic subtraction of the high-energy (HE) and low-energy (LE) image pairs. Temporal subtraction of the post-contrast DE images from the pre-contrast DE image is performed to analyze iodine uptake. Our previous work investigated image registration methods to correct for patient motion, enhancing the evaluation of vascular kinetics. In this project we investigate a segmentation algorithm which identifies blood vessels in the breast from our temporal DE subtraction images. Anisotropic diffusion filtering, Gabor filtering, and morphological filtering are used for the enhancement of vessel features. Vessel labeling methods are then used to distinguish vessel and background features successfully. Statistical and clinical evaluations of segmentation accuracy in DE-CBT images are ongoing.

  11. Application of Intraoperative Ultrasonography for Guiding Microneurosurgical Resection of Small Subcortical Lesions

    International Nuclear Information System (INIS)

    Wang, Jia; Duan, Yun You; Liu, Xi; Wang, Yu; Gao, Guo Dong; Qin, Huai Zhou; Wang, Liang

    2011-01-01

    We wanted to evaluate the clinical value of intraoperative ultrasonography for real-time guidance when performing microneurosurgical resection of small subcortical lesions. Fifty-two patients with small subcortical lesions were involved in this study. The pathological diagnoses were cavernous hemangioma in 25 cases, cerebral glioma in eight cases, abscess in eight cases, small inflammatory lesion in five cases, brain parasite infection in four cases and the presence of an intracranial foreign body in two cases. An ultrasonic probe was sterilized and lightly placed on the surface of the brain during the operation. The location, extent, characteristics and adjacent tissue of the lesion were observed by high frequency ultrasonography during the operation. All the lesions were located in the cortex and their mean size was 1.3 ± 0.2 cm. Intraoperative ultrasonography accurately located all the small subcortical lesions, and so the neurosurgeon could provide appropriate treatment. Different lesion pathologies presented with different ultrasonic appearances. Cavernous hemangioma exhibited irregular shapes with distinct margins and it was mildly hyperechoic or hyperechoic. The majority of the cerebral gliomas displayed irregular shapes with indistinct margins, and they often showed cystic and solid mixed echoes. Postoperative imaging identified that the lesions had completely disappeared, and the original symptoms of all the patients were significantly alleviated. Intraoperative ultrasonography can help accurately locate small subcortical lesions and it is helpful for selecting the proper approach and guiding thorough resection of these lesions.

  12. Application of Intraoperative Ultrasonography for Guiding Microneurosurgical Resection of Small Subcortical Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jia; Duan, Yun You; Liu, Xi; Wang, Yu; Gao, Guo Dong; Qin, Huai Zhou; Wang, Liang [Tangdu Hospital of the Fourth Military Medicine University, Xi an (China)

    2011-10-15

    We wanted to evaluate the clinical value of intraoperative ultrasonography for real-time guidance when performing microneurosurgical resection of small subcortical lesions. Fifty-two patients with small subcortical lesions were involved in this study. The pathological diagnoses were cavernous hemangioma in 25 cases, cerebral glioma in eight cases, abscess in eight cases, small inflammatory lesion in five cases, brain parasite infection in four cases and the presence of an intracranial foreign body in two cases. An ultrasonic probe was sterilized and lightly placed on the surface of the brain during the operation. The location, extent, characteristics and adjacent tissue of the lesion were observed by high frequency ultrasonography during the operation. All the lesions were located in the cortex and their mean size was 1.3 {+-} 0.2 cm. Intraoperative ultrasonography accurately located all the small subcortical lesions, and so the neurosurgeon could provide appropriate treatment. Different lesion pathologies presented with different ultrasonic appearances. Cavernous hemangioma exhibited irregular shapes with distinct margins and it was mildly hyperechoic or hyperechoic. The majority of the cerebral gliomas displayed irregular shapes with indistinct margins, and they often showed cystic and solid mixed echoes. Postoperative imaging identified that the lesions had completely disappeared, and the original symptoms of all the patients were significantly alleviated. Intraoperative ultrasonography can help accurately locate small subcortical lesions and it is helpful for selecting the proper approach and guiding thorough resection of these lesions.

  13. Dynamic contrast-enhanced MR of the prostatic cancer and benign prostatic hyperplasia: correlation with angiogenesis

    International Nuclear Information System (INIS)

    Ni Xinchu; Shen Junkang; Lu Zhian; Zhou Lijuan; Yang Xiaochun; Wang Guanzhong; Zhang Caiyuan; Wang Shuizhen; Qian Minghui; Chan Yuxi; Qian Nong; Xiang Jianpo; Pan Changjie; Rong Weiliang; Chen Jianguo

    2005-01-01

    Objective: To evaluate the role of dynamic contrast-enhanced magnetic resonance imaging (MRI) in the diagnose of prostatic cancer and benign prostatic hyperplasia (BPH), and to determine the correlation between dynamic MRI findings with angiogenesis. Methods: Thirty-two cases of prostatic cancer and 40 cases of BPH underwent dynamic contrast-enhanced MRI. All the patients in this study were diagnosed by histopathology. The results of dynamic contrast-enhanced MRI were evaluated by early-phase enhancement parameters and time-signal intensity curves (SI-T curves), and the curves were classified according to their shapes as type I, which had steady enhancement; type II, plateau of signal intensity; and type III, washout of signal intensity. The pathologic specimens of region of interest (ROI ) were obtained, and HE staining, immunohistochemical vascular endothelial growth factor (VEGF), and microvessel density (MVD) measurements were performed. The relationships among dynamic contrast-enhanced MRI features, VEGF, and MVD expression were analyzed. Results: In the early-phase enhancement parameters of dynamic contrast-enhanced MRI, onset time, maximum signal intensity, and early-phase enhancement rate differed between prostatic cancer and BPH (P<0.01, 0.05, 0.01), but there were some overlaps between them. The intermediate and late post-contrast periods were characterized with the lesion SI-T curves. The SI-T curve of prostatic cancer was mainly type III (21 cases). Type II could be seen in both prostatic cancer (8 cases) and BPH (19 cases). Type I most appeared in BPH (18 cases). The distributions proved to have significant difference (P<0.001). The mean VEGF and MVD level of 32 prostatic cancer patients were significantly higher than those of 40 BPH patients (P<0.001). MVD level of prostatic cancer and BPH showed an association with VEGF level (P<0.01). The maximum signal intensity and early-phase enhancement rate in both prostatic cancer and BPH showed an association

  14. Contrast enhancement by lipid-based MRI contrast agents in mouse atherosclerotic plaques; a longitudinal study

    NARCIS (Netherlands)

    den Adel, Brigit; van der Graaf, Linda M.; Que, Ivo; Strijkers, Gustav J.; Löwik, Clemens W.; Poelmann, Robert E.; van der Weerd, Louise

    2013-01-01

    The use of contrast-enhanced MRI to enable in vivo specific characterization of atherosclerotic plaques is increasing. In this study the intrinsic ability of two differently sized gadolinium-based contrast agents to enhance atherosclerotic plaques in ApoE(-/-) mice was evaluated with MRI. We

  15. Bioeffects of albumin-encapsulated microbubbles and real-time myocardial contrast echocardiography in an experimental canine model

    Directory of Open Access Journals (Sweden)

    P.M.M. Dourado

    2006-06-01

    Full Text Available Myocardial contrast echocardiography has been used for assessing myocardial perfusion. Some concerns regarding its safety still remain, mainly regarding the induction of microvascular alterations. We sought to determine the bioeffects of microbubbles and real-time myocardial contrast echocardiography (RTMCE in a closed-chest canine model. Eighteen mongrel dogs were randomly assigned to two groups. Nine were submitted to continuous intravenous infusion of perfluorocarbon-exposed sonicated dextrose albumin (PESDA plus continuous imaging using power pulse inversion RTMCE for 180 min, associated with manually deflagrated high-mechanical index impulses. The control group consisted of 3 dogs submitted to continuous imaging using RTMCE without PESDA, 3 dogs received PESDA alone, and 3 dogs were sham-operated. Hemodynamics and cardiac rhythm were monitored continuously. Histological analysis was performed on cardiac and pulmonary tissues. No hemodynamic changes or cardiac arrhythmias were observed in any group. Normal left ventricular ejection fraction and myocardial perfusion were maintained throughout the protocol. Frequency of mild and focal microhemorrhage areas in myocardial and pulmonary tissue was similar in PESDA plus RTMCE and control groups. The percentages of positive microscopical fields in the myocardium were 0.4 and 0.7% (P = NS in the PESDA plus RTMCE and control groups, respectively, and in the lungs they were 2.1 and 1.1%, respectively (P = NS. In this canine model, myocardial perfusion imaging obtained with PESDA and RTMCE was safe, with no alteration in cardiac rhythm or left ventricular function. Mild and focal myocardial and pulmonary microhemorrhages were observed in both groups, and may be attributed to surgical tissue manipulation.

  16. Real-time algorithms for JET hard X-ray and gamma-ray profile monitor

    International Nuclear Information System (INIS)

    Fernandes, A.; Pereira, R.C.; Valcárcel, D.F.; Alves, D.; Carvalho, B.B.; Sousa, J.; Kiptily, V.; Correia, C.M.B.A.; Gonçalves, B.

    2014-01-01

    Highlights: • Real-time tools and mechanisms are required for data handling and machine control. • A new DAQ system, ATCA based, with embedded FPGAs, was installed at JET. • Different real-time algorithms were developed for FPGAs and MARTe application. • MARTe provides the interface to CODAS and to the JET real-time network. • The new DAQ system is capable to process and deliver data in real-time. - Abstract: The steady state operation with high energy content foreseen for future generation of fusion devices will necessarily demand dedicated real-time tools and mechanisms for data handling and machine control. Consequently, the real-time systems for those devices should be carefully selected and their capabilities previously established. The Joint European Torus (JET) is undertaking an enhancement program, which includes tests of relevant real-time tools for the International Thermonuclear Experimental Reactor (ITER), a key experiment for future fusion devices. In these enhancements a new Data AcQuisition (DAQ) system is included, with real-time processing capabilities, for the JET hard X-ray and gamma-ray profile monitor. The DAQ system is composed of dedicated digitizer modules with embedded Field Programmable Gate Array (FPGA) devices. The interface between the DAQ system, the JET control and data acquisition system and the JET real-time data network is provided by the Multithreaded Application Real-Time executor (MARTe). This paper describes the real-time algorithms, developed for both digitizers’ FPGAs and MARTe application, capable of meeting the DAQ real-time requirements. The new DAQ system, including the embedded real-time features, was commissioned during the 2012 experiments. Results achieved with these real-time algorithms during experiments are presented

  17. Real-time algorithms for JET hard X-ray and gamma-ray profile monitor

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, A., E-mail: anaf@ipfn.ist.utl.pt [Associação EURATOM/IST, Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade Técnica de Lisboa, 1049-001 Lisboa (Portugal); Pereira, R.C.; Valcárcel, D.F.; Alves, D.; Carvalho, B.B.; Sousa, J. [Associação EURATOM/IST, Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade Técnica de Lisboa, 1049-001 Lisboa (Portugal); Kiptily, V. [EURATOM/CCFE Fusion Association, Culham Centre for Fusion Energy, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Correia, C.M.B.A. [Centro de Instrumentação, Dept. de Física, Universidade de Coimbra, 3004-516 Coimbra (Portugal); Gonçalves, B. [Associação EURATOM/IST, Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade Técnica de Lisboa, 1049-001 Lisboa (Portugal)

    2014-03-15

    Highlights: • Real-time tools and mechanisms are required for data handling and machine control. • A new DAQ system, ATCA based, with embedded FPGAs, was installed at JET. • Different real-time algorithms were developed for FPGAs and MARTe application. • MARTe provides the interface to CODAS and to the JET real-time network. • The new DAQ system is capable to process and deliver data in real-time. - Abstract: The steady state operation with high energy content foreseen for future generation of fusion devices will necessarily demand dedicated real-time tools and mechanisms for data handling and machine control. Consequently, the real-time systems for those devices should be carefully selected and their capabilities previously established. The Joint European Torus (JET) is undertaking an enhancement program, which includes tests of relevant real-time tools for the International Thermonuclear Experimental Reactor (ITER), a key experiment for future fusion devices. In these enhancements a new Data AcQuisition (DAQ) system is included, with real-time processing capabilities, for the JET hard X-ray and gamma-ray profile monitor. The DAQ system is composed of dedicated digitizer modules with embedded Field Programmable Gate Array (FPGA) devices. The interface between the DAQ system, the JET control and data acquisition system and the JET real-time data network is provided by the Multithreaded Application Real-Time executor (MARTe). This paper describes the real-time algorithms, developed for both digitizers’ FPGAs and MARTe application, capable of meeting the DAQ real-time requirements. The new DAQ system, including the embedded real-time features, was commissioned during the 2012 experiments. Results achieved with these real-time algorithms during experiments are presented.

  18. Improved Real-time Denoising Method Based on Lifting Wavelet Transform

    Directory of Open Access Journals (Sweden)

    Liu Zhaohua

    2014-06-01

    Full Text Available Signal denoising can not only enhance the signal to noise ratio (SNR but also reduce the effect of noise. In order to satisfy the requirements of real-time signal denoising, an improved semisoft shrinkage real-time denoising method based on lifting wavelet transform was proposed. The moving data window technology realizes the real-time wavelet denoising, which employs wavelet transform based on lifting scheme to reduce computational complexity. Also hyperbolic threshold function and recursive threshold computing can ensure the dynamic characteristics of the system, in addition, it can improve the real-time calculating efficiency as well. The simulation results show that the semisoft shrinkage real-time denoising method has quite a good performance in comparison to the traditional methods, namely soft-thresholding and hard-thresholding. Therefore, this method can solve more practical engineering problems.

  19. Evaluation of sacroiliitis: contrast-enhanced MRI with subtraction technique

    Energy Technology Data Exchange (ETDEWEB)

    Algin, Oktay; Gokalp, Gokhan; Baran, Bulent; Ocakoglu, Gokhan; Yazici, Zeynep [Uludag University, Medical Faculty, Department of Radiology, Gorukle, Bursa (Turkey)

    2009-10-15

    The purpose of the study was to investigate the diagnostic value of contrast-enhanced MRI using the subtraction technique in the detection of active sacroiliitis. Magnetic resonance imaging was performed in 8 asymptomatic volunteers and 50 patients with clinically suspected active sacroiliitis. On precontrast MR images, T1-weighted spin-echo images with and without fat saturation (T1WFS and T1W), STIR and 3D-FLASH images with fat saturation were obtained in the semicoronal plane using a 1.5 Tesla imager. Postcontrast MRI was performed using the same T1WFS sequence as before contrast injection for all volunteers and patients. Postcontrast images were subtracted from fat-suppressed precontrast images. Enhancement within the joint space and bone marrow was considered to demonstrate active sacroiliitis. In 50 patients (100 sacroiliac joints [SIJs]), 40 (76 SIJs) were considered to have active sacroiliitis based on MR images. Bone marrow edema was present in 33 patients (62 SIJs) on STIR images. Routine MRI allowed identification of contrast enhancement in SIJs on postcontrast T1WFS images in 31 patients (49 SIJs). Contrast enhancement was observed in 40 patients (76 SIJs) who were examined by MRI using the subtraction technique. Contrast enhancement was significantly more conspicuous on subtraction images than on non-subtracted postcontrast T1WFS images (Mann-Whitney U test, p<0.001). Contrast-enhanced MRI with subtraction technique may be useful for early detection of active sacroiliitis. (orig.)

  20. Assessment of renal perfusion with contrast-enhanced ultrasound: Preliminary results in early diabetic nephropathies.

    Science.gov (United States)

    Dong, Yi; Wang, Wen-Ping; Lin, Pan; Fan, Peili; Mao, Feng

    2016-01-01

    We performed a prospective study to evaluate the value of contrast-enhanced ultrasound (CEUS) in quantitative evaluation of renal cortex perfusion in patients suspected of early diabetic nephropathies (DN), with the estimated GFR (MDRD equation) as the gold standard. The study protocol was approved by the hospital review board; each patient gave written informed consent. Our study included 46 cases (21 males and 25 females, mean age 55.6 ± 4.14 years) of clinical confirmed early DN patients. After intravenous bolus injection of 1 ml sulfur hexafluoride microbubbles of ultrasound contrast agent, real time CEUS of renal cortex was performed successively using a 2-5 MHz convex probe. Time-intensity curves (TICs) and quantitative indexes were created with Qlab software. Receiver operating characteristic (ROC) curves were used to predict the diagnostic criteria of CEUS quantitative indexes, and their diagnostic efficiencies were compared with resistance index (RI) and peak systolic velocity (PSV) of renal segmental arteries by chi square test. Our control group included forty-five healthy volunteers. Difference was considered statistically significant with P  0.05). CEUS might be helpful to improve early diagnosis of DN by quantitative analyses. AUC and DPI might be valuable quantitative indexes.

  1. Real-time control environment for the RFX experiment

    International Nuclear Information System (INIS)

    Barana, O.; Cavinato, M.; Luchetta, A.; Manduchi, G.; Taliercio, C.

    2005-01-01

    A comprehensive set of control schemes can be presently implemented on RFX due to the enhanced load assembly and renewed power supply system. The schemes include: plasma equilibrium control and resistive wall mode stabilization, aiming at controlling actively the discharge when the passive action of the shell vanishes; the rotation of the localised helical deformation to minimize the enhanced plasma-wall interaction; the MHD mode control and the 'intelligent shell', aiming at achieving a better comprehension of the underlying physics. To the purpose, an integrated, distributed, digital system has been developed consisting of a set of computing nodes. Each node can act either as pre-processing or control station, the former acquiring raw data and computing intermediate control parameters, the latter executing control algorithms and driving the power amplifiers. An overview of the system architecture is presented in the paper with reference to the software real-time environment providing both basic functions, such as data read-out and real-time communication, and useful tools to program control algorithms, to perform simulations and to commission the system. To simulate the control schemes, the real-time environment is extended to include a so called 'simulation mode', in which the real-time nodes exchange their input/output signals with one station running a suitable model of the experiment, for instance the two dimensional FEM code MAXFEA in the case of the equilibrium control. In this way the control system can be tested offline and the time needed for the commissioning of algorithms reduced

  2. Performance Improvement of Real-Time System for Plasma Control in RFX-mod

    International Nuclear Information System (INIS)

    Luchetta, A.; Manduchi, G.; Soppelsa, A.; Taliercio, C.

    2006-01-01

    The real-time system for plasma control has been used routinely in RFX-mod since commissioning (mid 2005). It is based on a modular hardware/software infrastructure, currently including 7 VME stations, capable of fulfilling the tight system requirements in terms of input/output channels (> 700 / > 250), real-time data flow (> 2 Mbyte/s), computation capability (> 1 GFLOP/s per station), and real-time constraints (application cycle times rd EPS Conf. on Plasma Physics, Rome Italy, June 19 - 23 2006]. The high flexibility of the system has stimulated the development of a large number of control schemes with progressively increasing requests in terms of computation complexity and real-time data flow, demanding, at the same time, strict control on cycle times and system latency. Even though careful optimisation of algorithm implementation and real-time data transmission have been performed, allowing to keep pace, so far, with the increased control requirements, future developments require to evolve the current technology, retaining the basic architecture and concepts. Two system enhancements are envisaged in the near future. The 500 MHz PowerPC-based Single Board Computer currently in use will be substituted with the 1 GHz version, whereas the real-time communication system will increase in bandwidth from 100 Mbit/s to 1 Gbit/s. These improvements will surely enhance the overall system performance, even if it is not possible to quantify a priori the exact performance boost, since other components may limit the performance in the new configuration. The paper reports in detail on the analysis of the bottlenecks of the current architecture. Based on measurements carried out in laboratory, it presents the results achieved with the proposed enhancements in terms of real-time data throughput, cycle times and latency. The paper analyses in detail the effects of the increased computing power on the components of the control system and of the improved bandwidth in real-time

  3. Cloud-Hosted Real-time Data Services for the Geosciences (CHORDS)

    Science.gov (United States)

    Daniels, M. D.; Graves, S. J.; Vernon, F.; Kerkez, B.; Chandra, C. V.; Keiser, K.; Martin, C.

    2014-12-01

    Cloud-Hosted Real-time Data Services for the Geosciences (CHORDS) Access, utilization and management of real-time data continue to be challenging for decision makers, as well as researchers in several scientific fields. This presentation will highlight infrastructure aimed at addressing some of the gaps in handling real-time data, particularly in increasing accessibility of these data to the scientific community through cloud services. The Cloud-Hosted Real-time Data Services for the Geosciences (CHORDS) system addresses the ever-increasing importance of real-time scientific data, particularly in mission critical scenarios, where informed decisions must be made rapidly. Advances in the distribution of real-time data are leading many new transient phenomena in space-time to be observed, however real-time decision-making is infeasible in many cases that require streaming scientific data as these data are locked down and sent only to proprietary in-house tools or displays. This lack of accessibility to the broader scientific community prohibits algorithm development and workflows initiated by these data streams. As part of NSF's EarthCube initiative, CHORDS proposes to make real-time data available to the academic community via cloud services. The CHORDS infrastructure will enhance the role of real-time data within the geosciences, specifically expanding the potential of streaming data sources in enabling adaptive experimentation and real-time hypothesis testing. Adherence to community data and metadata standards will promote the integration of CHORDS real-time data with existing standards-compliant analysis, visualization and modeling tools.

  4. Potential Cost Savings of Contrast-Enhanced Digital Mammography.

    Science.gov (United States)

    Patel, Bhavika K; Gray, Richard J; Pockaj, Barbara A

    2017-06-01

    The purpose of this article is to discuss whether the sensitivity and specificity of contrast-enhanced digital mammography (CEDM) render it a viable diagnostic alternative to breast MRI. That CEDM couples low-energy images (comparable to the diagnostic quality of standard mammography) and subtracted contrast-enhanced mammograms make it a cost-effective modality and a realistic substitute for the more costly breast MRI.

  5. Ultrasonography as a diagnostic method in addition to mammography

    Energy Technology Data Exchange (ETDEWEB)

    Otto, H.; Roer, E.

    1988-05-01

    By using ultrasonography in addition to mammography, experienced diagnosticians essentially enhance the safety of their diagnosis of mammary gland diseases. The same applies to gynecomastia, the condition after plastic surgery, and mastitis.

  6. Efficacy of ultrasonography-guided shoulder MR arthrography using a posterior approach

    Energy Technology Data Exchange (ETDEWEB)

    Gokalp, Gokhan; Dusak, Abdurrahim; Yazici, Zeynep [Uludag University Medical Faculty, Goeruekle Kampusu, Department of Radiology, Bursa (Turkey)

    2010-06-15

    Shoulder MR arthrography has an important role in the assessment of rotator cuff lesions, labral tears, glenohumeral ligaments, rotator interval lesions, and postoperative shoulder status. Injection in direct MR arthrography can be performed with palpation, fluoroscopy, ultrasonography (US), or MRI. Recently, the posterior approach is the preferred method due to the presence of fewer stabilizers, absence of important articular structures and less extravasation, has been advocated. Our aim was to assess the efficacy of US-guided MR arthrography via a posterior approach on the glenohumeral joint. Thirty MR arthrographies were performed on 29 patients. Ultrasonography (Xario, Toshiba) examinations were conducted by a wide-band 5-12 Mhz linear array transducer set to muscle-skeleton. Diluted contrast medium (1 ml gadolinium chelate and 100 ml saline, approximately 15 ml) was delivered into the glenohumeral joint space from between the humeral head and posterior labrum with a 20-gauge spinal needle. MRI examination was conducted by a 1.5 T scanner. Fat-saturated T1-weighted spin echo was applied on coronal, axial, and sagittal planes within the first 30 min after contrast material injection. One (3.3%) arthrography was not successful due to technical reasons associated with obesity. Contrast extravasation around the infraspinatus and teres minoer muscles was depicted in twelve examinations. One (3.3%) patient developed vasovagal collapse. Ultrasonography-guided posterior approach is an easy, reliable, fast, and comfortable method in experienced hands. It may be an alternative for fluoroscopy-guided shoulder MR arthrography. (orig.)

  7. Efficacy of ultrasonography-guided shoulder MR arthrography using a posterior approach

    International Nuclear Information System (INIS)

    Gokalp, Gokhan; Dusak, Abdurrahim; Yazici, Zeynep

    2010-01-01

    Shoulder MR arthrography has an important role in the assessment of rotator cuff lesions, labral tears, glenohumeral ligaments, rotator interval lesions, and postoperative shoulder status. Injection in direct MR arthrography can be performed with palpation, fluoroscopy, ultrasonography (US), or MRI. Recently, the posterior approach is the preferred method due to the presence of fewer stabilizers, absence of important articular structures and less extravasation, has been advocated. Our aim was to assess the efficacy of US-guided MR arthrography via a posterior approach on the glenohumeral joint. Thirty MR arthrographies were performed on 29 patients. Ultrasonography (Xario, Toshiba) examinations were conducted by a wide-band 5-12 Mhz linear array transducer set to muscle-skeleton. Diluted contrast medium (1 ml gadolinium chelate and 100 ml saline, approximately 15 ml) was delivered into the glenohumeral joint space from between the humeral head and posterior labrum with a 20-gauge spinal needle. MRI examination was conducted by a 1.5 T scanner. Fat-saturated T1-weighted spin echo was applied on coronal, axial, and sagittal planes within the first 30 min after contrast material injection. One (3.3%) arthrography was not successful due to technical reasons associated with obesity. Contrast extravasation around the infraspinatus and teres minoer muscles was depicted in twelve examinations. One (3.3%) patient developed vasovagal collapse. Ultrasonography-guided posterior approach is an easy, reliable, fast, and comfortable method in experienced hands. It may be an alternative for fluoroscopy-guided shoulder MR arthrography. (orig.)

  8. Shear-wave elastography in breast ultrasonography: the state of the art

    Directory of Open Access Journals (Sweden)

    Ji Hyun Youk

    2017-10-01

    Full Text Available Shear-wave elastography (SWE is a recently developed ultrasound technique that can visualize and measure tissue elasticity. In breast ultrasonography, SWE has been shown to be useful for differentiating benign breast lesions from malignant breast lesions, and it has been suggested that SWE enhances the diagnostic performance of ultrasonography, potentially improving the specificity of conventional ultrasonography using the Breast Imaging Reporting and Data System criteria. More recently, not only has SWE been proven useful for the diagnosis of breast cancer, but has also been shown to provide valuable information that can be used as a preoperative predictor of the prognosis or response to chemotherapy.

  9. Shear-wave elastography in breast ultrasonography: the state of the art

    Energy Technology Data Exchange (ETDEWEB)

    Youk, Ji Hyun; Gweon, Hye Mi; Son, Eun Ju [Dept. of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-10-15

    Shear-wave elastography (SWE) is a recently developed ultrasound technique that can visualize and measure tissue elasticity. In breast ultrasonography, SWE has been shown to be useful for differentiating benign breast lesions from malignant breast lesions, and it has been suggested that SWE enhances the diagnostic performance of ultrasonography, potentially improving the specificity of conventional ultrasonography using the Breast Imaging Reporting and Data System criteria. More recently, not only has SWE been proven useful for the diagnosis of breast cancer, but has also been shown to provide valuable information that can be used as a preoperative predictor of the prognosis or response to chemotherapy.

  10. Abdominal vascular and visceral parenchymal contrast enhancement in MDCT: Effects of injection duration

    Energy Technology Data Exchange (ETDEWEB)

    Tsuge, Yusuke, E-mail: tsugeu@cup.ocn.ne.jp [Department of Radiology, Kizawa Memorial Hospital, 590 Kobityo Shimokobi, Minokamo City, Gifu 505-8503 (Japan); Kanematsu, Masayuki [Department of Radiology, Gifu University Hospital, Gifu (Japan); Department of Radiology Services, Gifu University Hospital, Gifu (Japan); Goshima, Satoshi; Kondo, Hiroshi [Department of Radiology, Gifu University Hospital, Gifu (Japan); Yokoyama, Ryujiro; Miyoshi, Toshiharu [Department of Radiology Services, Gifu University Hospital, Gifu (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka (Japan); Moriyama, Noriyuki [Research Center for Cancer Prevention and Screening, National Cancer Center Hospital, Tsukiji (Japan); Bae, Kyongtae T. [Radiology and Biomedical Engineering, University of Pittsburgh, Pittsburgh, PA (United States)

    2011-11-15

    Purpose: To evaluate and compare the effect of short and long injection durations on aortic, pancreatic and hepatic enhancement in abdominal MDCT. Methods and materials: Triphasic contrast-enhanced CT images (16-MDCT, 1.25-mm collimation, 5-mm thickness, 6.1-s acquisition time for each phase) were obtained with 2 mL/kg injection of 300 mgI/mL iodine contrast material in 116 patients. Patients were prospectively randomized into two groups: one receiving contrast medium for 25-s injection duration and the other for 35-s injection duration. In both groups, triphasic scans were initiated 5, 15, and 40 s after the completion of contrast injection for the first, second and third phases, respectively. CT values (HU) in the abdominal aorta, liver, spleen, pancreas, splenic and superior mesenteric arteries, and veins (splenic, superior mesenteric, portal, and hepatic) were measured. Quantitative and qualitative analysis for the degree of contrast enhancement between the two groups in various organs was compared at each scan phase. Results: The aortic and arterial enhancements in the first-phase scan were higher for the 25-s group than those of the 35-s group (P < .001). Hepatic enhancement was higher for the 35-s group in the first (P < .001) and second (P < .01) phases, but no difference in the third-phase. No difference was found between the groups for the pancreatic enhancement at any phases. Qualitative results were in good agreement with quantitative results. Conclusion: Contrast administration with shorter injection duration increased peak aortic and arterial enhancement and contributed to improvement in the quality of CT angiograms, but for the solid abdominal organs 35-s protocol is recommended.

  11. Prognostic value of contrast-enhanced MR mammography in patients with breast cancer

    International Nuclear Information System (INIS)

    Fischer, U.; Kopka, L.; Brinck, U.; Korabiowska, M.; Schauer, A.; Grabbe, E.

    1997-01-01

    The objective of this study was to evaluate the prognostic value of contrast-enhanced MR mammography in patients with breast cancer. A total of 190 patients with breast cancer (37 noninvasive carcinomas, 153 invasive carcinomas) underwent dynamic contrast-enhanced MR mammography preoperatively. Using 1.5-T unit, T1-weighted sequences (2D FLASH) were obtained repeatedly one time before and five times after IV administration of 0.1 mmol gadopentetate-dimeglumine per kilogram body weight. The findings on MR imaging were correlated with histopathologically defined prognostic factors (histological type, tumor size, tumor grading, metastasis in lymph nodes). In addition, immunohistochemically defined prognostic factors (c-erbB-1,c-erbB-2, p53, Ki-67) were correlated with the signal increase on MR mammogram in 40 patients. There was no significant correlation between the findings on MR mammography and the histopathological type of carcinoma, the grading, and the lymphonodular status. Noninvasive carcinomas showed a higher rate of moderate (38 %) or low (27 %) enhancement on MR imaging than invasive carcinomas (6 and 3 %). The results on MR mammography and the results of immunohistochemical stainings did not correlate significantly. Noninvasive carcinomas showed significantly lower enhancement than invasive carcinomas. However, the signal behavior of contrast-enhanced MR mammography is not related to established histopathological prognostic parameters as subtyping, grading, nodal status, and the expression of certain oncogenes/tumor suppressor genes. (orig.). With 5 tabs

  12. The impact of injector-based contrast agent administration in time-resolved MRA.

    Science.gov (United States)

    Budjan, Johannes; Attenberger, Ulrike I; Schoenberg, Stefan O; Pietsch, Hubertus; Jost, Gregor

    2018-05-01

    Time-resolved contrast-enhanced MR angiography (4D-MRA), which allows the simultaneous visualization of the vasculature and blood-flow dynamics, is widely used in clinical routine. In this study, the impact of two different contrast agent injection methods on 4D-MRA was examined in a controlled, standardized setting in an animal model. Six anesthetized Goettingen minipigs underwent two identical 4D-MRA examinations at 1.5 T in a single session. The contrast agent (0.1 mmol/kg body weight gadobutrol, followed by 20 ml saline) was injected using either manual injection or an automated injection system. A quantitative comparison of vascular signal enhancement and quantitative renal perfusion analyses were performed. Analysis of signal enhancement revealed higher peak enhancements and shorter time to peak intervals for the automated injection. Significantly different bolus shapes were found: automated injection resulted in a compact first-pass bolus shape clearly separated from the recirculation while manual injection resulted in a disrupted first-pass bolus with two peaks. In the quantitative perfusion analyses, statistically significant differences in plasma flow values were found between the injection methods. The results of both qualitative and quantitative 4D-MRA depend on the contrast agent injection method, with automated injection providing more defined bolus shapes and more standardized examination protocols. • Automated and manual contrast agent injection result in different bolus shapes in 4D-MRA. • Manual injection results in an undefined and interrupted bolus with two peaks. • Automated injection provides more defined bolus shapes. • Automated injection can lead to more standardized examination protocols.

  13. A contrast-enhanced ultrasound study of benign and malignant ...

    African Journals Online (AJOL)

    A contrast-enhanced ultrasound study of benign and malignant breast tissue. S Barnard, E Leen, T Cooke, W Angerson. Abstract. Objective. To determine the diagnostic value of haemodynamic contrast-enhanced ultrasound assessment in benign and malignant breast tissue, using histological examination as the reference ...

  14. Contrast enhancement of cerebral infarcts. Incidence and clinical value in different states of cerebral infarction

    International Nuclear Information System (INIS)

    Skriver, E.B.; Olsen, T.S.

    1982-01-01

    Information obtained from CT scan after contrast administration was evaluated in 59 consecutive stroke patients. CT scans before and after contrast administration were performed 3 days and 2 1/2 weeks after stroke. A plain CT scan was repeated 6 months later. Contrast enhancement was practically not seen on the first examination, but was seen in 46% on the second examination. There was a close relationship between the occurrence of contrast enhancement and the so called fogging effect. Contrast scanning gave additional information only when this effect was present. Plain CT scans 3 days after stroke were superior to contrast scans taken at any time for detecting and visualizing cerebral infarcts. (orig.)

  15. UWGSP7: a real-time optical imaging workstation

    Science.gov (United States)

    Bush, John E.; Kim, Yongmin; Pennington, Stan D.; Alleman, Andrew P.

    1995-04-01

    that supports the RS-170 standard. The image acquisition board is connected to the image- processing board using a direct connect port which provides a 66 Mbytes/s channel independent of the system bus. The image processing board utilizes the Texas Instruments TMS320C80 Multimedia Video Processor chip. This chip is capable of 2 billion operations per second providing the UWGSP7 with the capability to perform real-time image processing functions like median filtering, convolution and contrast enhancement. This processing power allows interactive analysis of the experiments as compared to current practice of off-line processing and analysis. Due to its flexibility and programmability, the UWGSP7 can be adapted into various research needs in intraoperative optical imaging.

  16. Realistic 3D Terrain Roaming and Real-Time Flight Simulation

    Science.gov (United States)

    Que, Xiang; Liu, Gang; He, Zhenwen; Qi, Guang

    2014-12-01

    This paper presents an integrate method, which can provide access to current status and the dynamic visible scanning topography, to enhance the interactive during the terrain roaming and real-time flight simulation. A digital elevation model and digital ortho-photo map data integrated algorithm is proposed as the base algorithm for our approach to build a realistic 3D terrain scene. A new technique with help of render to texture and head of display for generating the navigation pane is used. In the flight simulating, in order to eliminate flying "jump", we employs the multidimensional linear interpolation method to adjust the camera parameters dynamically and steadily. Meanwhile, based on the principle of scanning laser imaging, we draw pseudo color figures by scanning topography in different directions according to the real-time flying status. Simulation results demonstrate that the proposed algorithm is prospective for applications and the method can improve the effect and enhance dynamic interaction during the real-time flight.

  17. Is contrast-enhanced CT indicated in acute head injury

    International Nuclear Information System (INIS)

    Mauser, H.W.; Nieuwenhuizen, O. van; Veiga-Pires, J.A.

    1984-01-01

    The authors discuss the value of intravenous contrast enhancement in CT scanning in acute head injury. In a series of seventy consecutive patients they conclude that no incremental information was obtained by performing contrast-enhanced CT scans in the acute phase of the head injury. (orig.)

  18. Ultrasonography of the biliary tract - up to date. The importance of correlation between imaging methods and patients' signs and symptoms.

    Science.gov (United States)

    Badea, Radu; Zaro, Răzvan; Tanțău, Marcel; Chiorean, Liliana

    2015-09-01

    Ultrasonography is generally accepted and performed as a first choice imaging technique in patients with jaundice. The method allows the discrimination between cholestatic and mechanical jaundice. The existing procedures are multiple: gray scale, Doppler, i.v. contrast enhancement, elastography, tridimensional ultrasonography, each of these with different contribution to the positive and differential diagnosis regarding the nature of the jaundice. The final diagnosis is a multimodal one and the efficiency is dependent on the level of the available technology, the examiner's experience, the degree and modality of integration of the data within the clinical context, as well as on the portfolio of available imaging procedures. This review shows the main ultrasonographic methods consecrated in the evaluation of the biliary tree. It also underlines the integrated character of the procedures, as well as the necessity to correlate with other imaging methods and the clinical situation.

  19. Medial tibial pain: a dynamic contrast-enhanced MRI study.

    Science.gov (United States)

    Mattila, K T; Komu, M E; Dahlström, S; Koskinen, S K; Heikkilä, J

    1999-09-01

    The purpose of this study was to compare the sensitivity of different magnetic resonance imaging (MRI) sequences to depict periosteal edema in patients with medial tibial pain. Additionally, we evaluated the ability of dynamic contrast-enhanced imaging (DCES) to depict possible temporal alterations in muscular perfusion within compartments of the leg. Fifteen patients with medial tibial pain were examined with MRI. T1-, T2-weighted, proton density axial images and dynamic and static phase post-contrast images were compared in ability to depict periosteal edema. STIR was used in seven cases to depict bone marrow edema. Images were analyzed to detect signs of compartment edema. Region-of-interest measurements in compartments were performed during DCES and compared with controls. In detecting periosteal edema, post-contrast T1-weighted images were better than spin echo T2-weighted and proton density images or STIR images, but STIR depicted the bone marrow edema best. DCES best demonstrated the gradually enhancing periostitis. Four subjects with severe periosteal edema had visually detectable pathologic enhancement during DCES in the deep posterior compartment of the leg. Percentage enhancement in the deep posterior compartment of the leg was greater in patients than in controls. The fast enhancement phase in the deep posterior compartment began slightly slower in patients than in controls, but it continued longer. We believe that periosteal edema in bone stress reaction can cause impairment of venous flow in the deep posterior compartment. MRI can depict both these conditions. In patients with medial tibial pain, MR imaging protocol should include axial STIR images (to depict bone pathology) with T1-weighted axial pre and post-contrast images, and dynamic contrast enhanced imaging to show periosteal edema and abnormal contrast enhancement within a compartment.

  20. Real-time virtual sonography (RVS)-guided vacuum-assisted breast biopsy for lesions initially detected with breast MRI.

    Science.gov (United States)

    Uematsu, Takayoshi

    2013-12-01

    To report on our initial experiences with a new method of real-time virtual sonography (RVS)-guided 11-gauge vacuum-assisted breast biopsy for lesions that were initially detected with breast MRI. RVS-guided 11-gauge vacuum-assisted biopsy is performed when a lesion with suspicious characteristics is initially detected with breast MRI and is occult on mammography, sonography, and physical examination. Live sonographic images were co-registered to the previously loaded second-look spine contrast-enhanced breast MRI volume data to correlate the sonography and MR images. Six lesions were examined in six consecutive patients scheduled to undergo RVS-guided 11-gauge vacuum-assisted biopsy. One patient was removed from the study because of non-visualization of the lesion in the second-look spine contrast-enhanced breast MRI. Five patients with non-mass enhancement lesions were biopsied. The lesions ranged in size from 9 to 13 mm (mean 11 mm). The average procedural time, including the sonography and MR image co-registration time, was 25 min. All biopsies resulted in tissue retrieval. One was fibroadenomatous nodules, and those of four were fibrocystic changes. There were no complications during or after the procedures. RVS-guided 11-gauge vacuum-assisted breast biopsies provide a safe and effective method for the examination of suspicious lesions initially detected with MRI.

  1. Contrast-enhanced dedicated breast CT detection of invasive breast cancer preceding mammographic diagnosis

    Directory of Open Access Journals (Sweden)

    Nicolas D. Prionas, MD, PhD

    2015-01-01

    Full Text Available Dedicated breast computed tomography (bCT generates high-resolution, three-dimensional images of the pendent uncompressed breast. Intravenous iodinated contrast during bCT provides additional physiologic information. In this case, a 10.0-mm invasive ductal carcinoma was visualized using contrast-enhanced breast CT one year before mammographic detection. Mammography four months before bCT was negative. The bCT contrast enhancement pattern closely matched the dynamic contrast-enhanced MRI obtained after diagnosis. Lesion enhancement at contrast-enhanced breast CT matched previously published enhancement values of breast cancer. Contrast-enhanced dedicated bCT provided high-resolution tomographic images and physiologic contrast enhancement data that facilitated the detection of an early breast cancer.

  2. Contrast Enhancement Algorithm Based on Gap Adjustment for Histogram Equalization

    Science.gov (United States)

    Chiu, Chung-Cheng; Ting, Chih-Chung

    2016-01-01

    Image enhancement methods have been widely used to improve the visual effects of images. Owing to its simplicity and effectiveness histogram equalization (HE) is one of the methods used for enhancing image contrast. However, HE may result in over-enhancement and feature loss problems that lead to unnatural look and loss of details in the processed images. Researchers have proposed various HE-based methods to solve the over-enhancement problem; however, they have largely ignored the feature loss problem. Therefore, a contrast enhancement algorithm based on gap adjustment for histogram equalization (CegaHE) is proposed. It refers to a visual contrast enhancement algorithm based on histogram equalization (VCEA), which generates visually pleasing enhanced images, and improves the enhancement effects of VCEA. CegaHE adjusts the gaps between two gray values based on the adjustment equation, which takes the properties of human visual perception into consideration, to solve the over-enhancement problem. Besides, it also alleviates the feature loss problem and further enhances the textures in the dark regions of the images to improve the quality of the processed images for human visual perception. Experimental results demonstrate that CegaHE is a reliable method for contrast enhancement and that it significantly outperforms VCEA and other methods. PMID:27338412

  3. Contrast Enhancement Algorithm Based on Gap Adjustment for Histogram Equalization

    Directory of Open Access Journals (Sweden)

    Chung-Cheng Chiu

    2016-06-01

    Full Text Available Image enhancement methods have been widely used to improve the visual effects of images. Owing to its simplicity and effectiveness histogram equalization (HE is one of the methods used for enhancing image contrast. However, HE may result in over-enhancement and feature loss problems that lead to unnatural look and loss of details in the processed images. Researchers have proposed various HE-based methods to solve the over-enhancement problem; however, they have largely ignored the feature loss problem. Therefore, a contrast enhancement algorithm based on gap adjustment for histogram equalization (CegaHE is proposed. It refers to a visual contrast enhancement algorithm based on histogram equalization (VCEA, which generates visually pleasing enhanced images, and improves the enhancement effects of VCEA. CegaHE adjusts the gaps between two gray values based on the adjustment equation, which takes the properties of human visual perception into consideration, to solve the over-enhancement problem. Besides, it also alleviates the feature loss problem and further enhances the textures in the dark regions of the images to improve the quality of the processed images for human visual perception. Experimental results demonstrate that CegaHE is a reliable method for contrast enhancement and that it significantly outperforms VCEA and other methods.

  4. Facial nerve palsy: Evaluation by contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Kinoshita, T.; Ishii, K.; Okitsu, T.; Okudera, T.; Ogawa, T.

    2001-01-01

    AIM: The purpose of this study was to investigate the value of contrast-enhanced magnetic resonance (MR) imaging in patients with peripheral facial nerve palsy. MATERIALS AND METHODS: MR imaging was performed in 147 patients with facial nerve palsy, using a 1.0 T unit. All of 147 patients were evaluated by contrast-enhanced MR imaging and the pattern of enhancement was compared with that in 300 control subjects evaluated for suspected acoustic neurinoma. RESULTS: The intrameatal and labyrinthine segments of the normal facial nerve did not show enhancement, whereas enhancement of the distal intrameatal segment and the labyrinthine segment was respectively found in 67% and 43% of patients with Bell's palsy. The geniculate ganglion or the tympanic-mastoid segment was enhanced in 21% of normal controls versus 91% of patients with Bell's palsy. Abnormal enhancement of the non-paralyzed facial nerve was found in a patient with bilateral temporal bone fracture. CONCLUSION: Enhancement of the distal intrameatal and labyrinthine segments is specific for facial nerve palsy. Contrast-enhanced MR imaging can reveal inflammatory facial nerve lesions and traumatic nerve injury, including clinically silent damage in trauma. Kinoshita T. et al. (2001)

  5. Facial nerve palsy: Evaluation by contrast-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, T.; Ishii, K.; Okitsu, T.; Okudera, T.; Ogawa, T

    2001-11-01

    AIM: The purpose of this study was to investigate the value of contrast-enhanced magnetic resonance (MR) imaging in patients with peripheral facial nerve palsy. MATERIALS AND METHODS: MR imaging was performed in 147 patients with facial nerve palsy, using a 1.0 T unit. All of 147 patients were evaluated by contrast-enhanced MR imaging and the pattern of enhancement was compared with that in 300 control subjects evaluated for suspected acoustic neurinoma. RESULTS: The intrameatal and labyrinthine segments of the normal facial nerve did not show enhancement, whereas enhancement of the distal intrameatal segment and the labyrinthine segment was respectively found in 67% and 43% of patients with Bell's palsy. The geniculate ganglion or the tympanic-mastoid segment was enhanced in 21% of normal controls versus 91% of patients with Bell's palsy. Abnormal enhancement of the non-paralyzed facial nerve was found in a patient with bilateral temporal bone fracture. CONCLUSION: Enhancement of the distal intrameatal and labyrinthine segments is specific for facial nerve palsy. Contrast-enhanced MR imaging can reveal inflammatory facial nerve lesions and traumatic nerve injury, including clinically silent damage in trauma. Kinoshita T. et al. (2001)

  6. Real-time optimisation of the Hoa Binh reservoir, Vietnam

    DEFF Research Database (Denmark)

    Richaud, Bertrand; Madsen, Henrik; Rosbjerg, Dan

    2011-01-01

    -time optimisation. First, the simulation-optimisation framework is applied for optimising reservoir operating rules. Secondly, real-time and forecast information is used for on-line optimisation that focuses on short-term goals, such as flood control or hydropower generation, without compromising the deviation...... in the downstream part of the Red River, and at the same time to increase hydropower generation and to save water for the dry season. The real-time optimisation procedure further improves the efficiency of the reservoir operation and enhances the flexibility for the decision-making. Finally, the quality......Multi-purpose reservoirs often have to be managed according to conflicting objectives, which requires efficient tools for trading-off the objectives. This paper proposes a multi-objective simulation-optimisation approach that couples off-line rule curve optimisation with on-line real...

  7. Software-triggered contrast-enhanced three-dimensional MR angiography of the intracranial arteries.

    Science.gov (United States)

    Isoda, H; Takehara, Y; Isogai, S; Takeda, H; Tanaka, T; Takahashi, M; Nozaki, A; Sun, Y

    2000-02-01

    We investigated the effectiveness of software-triggered contrast-enhanced three-dimensional (3D) MR angiography in evaluating intracranial arteries. We studied 38 patients with suspected brain lesions. Imaging was performed using a 1.5-T superconducting MR system with a commercially available head coil. To monitor signal intensity changes we used software to place a tracker volume at the basilar artery or the internal carotid artery. A 20-ml bolus of gadodiamide hydrate was administered through the antecubital vein at a rate of 2-4 ml/sec, followed by a saline flush. Three-dimensional MR angiography using a spoiled gradient-echo sequence with centric K-space ordering was triggered by the arrival of the contrast bolus in the tracker volume. Imaging times ranged from 12 to 20 sec. We used MR images to assess the effectiveness of contrast-enhanced 3D MR angiography in revealing intracranial arteries with minimal venous overlap. The software triggered imaging on the arrival of the contrast bolus in 81.6% of examinations. In 77.6% of examinations, the resulting MR angiograms revealed intracranial arteries with minimal venous overlap. Software-triggered contrast-enhanced 3D MR angiography with centric K-space ordering is a promising technique for viewing intracranial arteries.

  8. Contrast-enhanced sonography for quantitative assessment of portal hypertension in patients with liver cirrhosis.

    Science.gov (United States)

    Qu, En-Ze; Zhang, Ying-Cai; Li, Zhi-Yan; Liu, Yang; Wang, Jin-Rui

    2014-11-01

    The clinical utility of contrast-enhanced sonography in portal hypertension remains unclear. We explored the feasibility of using contrast-enhanced sonography for noninvasive assessment of portal venous pressure. Twenty healthy individuals (control group; 9 men; mean age, 46.4 years) and 18 patients with portal hypertension (15 men; mean age, 46.2 years) were enrolled in this study. The portal hypertension group included patients who underwent splenectomy and pericardial blood vessel disarticulation at our hospital from October 2010 to March 2011. One week before surgery, patients with portal hypertension underwent preoperative liver contrast-enhanced sonography. Two-dimensional, Doppler, and contrast-enhanced sonographic parameters were compared between the groups. Portal venous pressure was measured intraoperatively by portal vein puncture in the portal hypertension group, and its relationship with the other parameters was analyzed. The 2-dimensional, Doppler, and contrast-enhanced sonographic parameters differed between the groups (P Portal venous pressure was inversely correlated with the area under the portal vein/hepatic artery time-intensity curve ratio (Qp/Qa), portal vein/hepatic artery strength ratio (Ip/Ia), and portal vein/hepatic artery wash-in perfusion slope ratio (βp/βa), with correlation coefficients of -0.701, -0.625, and -0.494, respectively. Measurement of the liver contrast-enhanced sonographic parameters Qp/Qa, Ip/Ia, and βp/βa could be used as a new quantitative method for noninvasively assessing portal venous pressure. © 2014 by the American Institute of Ultrasound in Medicine.

  9. Parameter estimation and change-point detection from Dynamic Contrast Enhanced MRI data using stochastic differential equations.

    Science.gov (United States)

    Cuenod, Charles-André; Favetto, Benjamin; Genon-Catalot, Valentine; Rozenholc, Yves; Samson, Adeline

    2011-09-01

    Dynamic Contrast Enhanced imaging (DCE-imaging) following a contrast agent bolus allows the extraction of information on tissue micro-vascularization. The dynamic signals obtained from DCE-imaging are modeled by pharmacokinetic compartmental models which integrate the Arterial Input Function. These models use ordinary differential equations (ODEs) to describe the exchanges between the arterial and capillary plasma and the extravascular-extracellular space. Their least squares fitting takes into account measurement noises but fails to deal with unpredictable fluctuations due to external/internal sources of variations (patients' anxiety, time-varying parameters, measurement errors in the input function, etc.). Adding Brownian components to the ODEs leads to stochastic differential equations (SDEs). In DCE-imaging, SDEs are discretely observed with an additional measurement noise. We propose to estimate the parameters of these noisy SDEs by maximum likelihood, using the Kalman filter. In DCE-imaging, the contrast agent injected in vein arrives in plasma with an unknown time delay. The delay parameter induces a change-point in the drift of the SDE and ODE models, which is estimated also. Estimations based on the SDE and ODE pharmacokinetic models are compared to real DCE-MRI data. They show that the use of SDE provides robustness in the estimation results. A simulation study confirms these results. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. GPU-Accelerated Real-Time Surveillance De-Weathering

    OpenAIRE

    Pettersson, Niklas

    2013-01-01

    A fully automatic de-weathering system to increase the visibility/stability in surveillance applications during bad weather has been developed. Rain, snow and haze during daylight are handled in real-time performance with acceleration from CUDA implemented algorithms. Video from fixed cameras is processed on a PC with no need of special hardware except an NVidia GPU. The system does not use any background model and does not require any precalibration. Increase in contrast is obtained in all h...

  11. Algorithms for contrast enhancement of electronic portal images

    International Nuclear Information System (INIS)

    Díez, S.; Sánchez, S.

    2015-01-01

    An implementation of two new automatized image processing algorithms for contrast enhancement of portal images is presented as suitable tools which facilitate the setup verification and visualization of patients during radiotherapy treatments. In the first algorithm, called Automatic Segmentation and Histogram Stretching (ASHS), the portal image is automatically segmented in two sub-images delimited by the conformed treatment beam: one image consisting of the imaged patient obtained directly from the radiation treatment field, and the second one is composed of the imaged patient outside it. By segmenting the original image, a histogram stretching can be independently performed and improved in both regions. The second algorithm involves a two-step process. In the first step, a Normalization to Local Mean (NLM), an inverse restoration filter is applied by dividing pixel by pixel a portal image by its blurred version. In the second step, named Lineally Combined Local Histogram Equalization (LCLHE), the contrast of the original image is strongly improved by a Local Contrast Enhancement (LCE) algorithm, revealing the anatomical structures of patients. The output image is lineally combined with a portal image of the patient. Finally the output images of the previous algorithms (NLM and LCLHE) are lineally combined, once again, in order to obtain a contrast enhanced image. These two algorithms have been tested on several portal images with great results. - Highlights: • Two Algorithms are implemented to improve the contrast of Electronic Portal Images. • The multi-leaf and conformed beam are automatically segmented into Portal Images. • Hidden anatomical and bony structures in portal images are revealed. • The task related to the patient setup verification is facilitated by the contrast enhancement then achieved.

  12. Real-Time Scheduling for Preventing Information Leakage with Preemption Overheads

    Directory of Open Access Journals (Sweden)

    BAEK, H.

    2017-05-01

    Full Text Available Real-time systems (RTS are characterized by tasks executing in a timely manner to meet its deadlines as a real-time constraint. Most studies of RTS have focused on these criteria as primary design points. However, recent increases in security threats to various real-time systems have shown that enhanced security support must be included as an important design point, retro-fitting such support to existing systems as necessary. In this paper, we propose a new pre-flush technique referred to as flush task reservation for FP scheduling (FTR-FP to conditionally sanitize the state of resources shared by real-time tasks by invoking a flush task (FT in order to mitigate information leakage/corruption of real-time systems. FTR-FP extends existing works exploiting FTs to be applicable more general scheduling algorithms and security model. We also propose modifications to existing real-time scheduling algorithms to implement a pre-flush technique as a security constraint, and analysis technique to verify schedulability of the real-time scheduling. For better analytic capability, our analysis technique provides a count of the precise number of preemptions that a task experiences offline. Our evaluation results demonstrate that our proposed schedulability analysis improves the performance of existing scheduling algorithms in terms of schedulability and preemption cost.

  13. Applications of contrast enhanced CT through external jugular access

    International Nuclear Information System (INIS)

    Xu Qiaolan; Zou Wenxing; Chen Meixia; Xie Hongbo

    2005-01-01

    Objective: A retrospective analysis and evaluation for the effects of contrast enhanced computed tomography through external jugular access. Methods: 1250 cases (male 692 and female 558) underwent CT contrast enhanced examination were retrospectively reviewed from May, 2002 to Oct, 2002. The patients aged from 12 to 86 years, averagely 49 years. Contrast agent (Ultravist) was given through an intravenous catheter placed in the cubital vein. Precise injection rates were ensured by a power injector (Medrad MCT310, USA). Excellent enhancement was achieved with this protocol in most of the patients, while external jugular access was established in 96 cases because it was unable to setup a cubital venous access. Results: Good enhancement were acquired when 96 cases of contrast agent injected through external jugular vein. And the external jugular access was setup successfully with a single puncture. Conclusion: It is a common occasion when patient undergoing contrast enhanced CT scan is in poor conditions: debility, cachexia, or with complication of chemotherapy or radiation therapy, which often results in invalidity of cabital venous access, and consequently, making bolus injection impossible. The external jugular vein is a large and central blood vessel, which is easy to setup an access. In our experience, an external jugular access should be recommended as a substitution if the cubital venous access is not available. (authors)

  14. Applications of contrast enhanced CT through external jugular access

    Energy Technology Data Exchange (ETDEWEB)

    Qiaolan, Xu; Wenxing, Zou; Meixia, Chen; Hongbo, Xie [The First Affiliated Hospital of Sun Yat-sen University, Guangzhou (China). Dept. of Radiology

    2005-09-15

    Objective: A retrospective analysis and evaluation for the effects of contrast enhanced computed tomography through external jugular access. Methods: 1250 cases (male 692 and female 558) underwent CT contrast enhanced examination were retrospectively reviewed from May, 2002 to Oct, 2002. The patients aged from 12 to 86 years, averagely 49 years. Contrast agent (Ultravist) was given through an intravenous catheter placed in the cubital vein. Precise injection rates were ensured by a power injector (Medrad MCT310, USA). Excellent enhancement was achieved with this protocol in most of the patients, while external jugular access was established in 96 cases because it was unable to setup a cubital venous access. Results: Good enhancement were acquired when 96 cases of contrast agent injected through external jugular vein. And the external jugular access was setup successfully with a single puncture. Conclusion: It is a common occasion when patient undergoing contrast enhanced CT scan is in poor conditions: debility, cachexia, or with complication of chemotherapy or radiation therapy, which often results in invalidity of cabital venous access, and consequently, making bolus injection impossible. The external jugular vein is a large and central blood vessel, which is easy to setup an access. In our experience, an external jugular access should be recommended as a substitution if the cubital venous access is not available. (authors)

  15. The current status of the three-dimensional ultrasonography in gyneaecology

    Energy Technology Data Exchange (ETDEWEB)

    Ong, Chiou Li [Dept. of Diagnostic and Interventional Imaging, KK Women' s and Children' s Hospital, Singapore (Singapore)

    2016-01-15

    Ultrasonography (US) is the most recent cross-sectional imaging modality to acquire three-dimensional (3D) capabilities. The reconstruction of volumetric US data for multiplanar display took a significantly longer time to develop in comparison with computed tomography and magnetic resonance imaging. The current equipment for 3D-US is capable of producing high-resolution images in three different planes, including real-time surface-rendered images. The use of 3D-US in gynaecology was accelerated through the development of the endovaginal volume transducer, which allows the automated acquisition of volumetric US data. Although initially considered an adjunct to two-dimensional US, 3D-US is now the imaging modality of choice for the assessment of Müllerian duct anomalies and the location of intrauterine devices.

  16. Differentiation of benign and malignant solitary pulmonary nodules : value of contrast-enhanced dynamic MR imaging

    International Nuclear Information System (INIS)

    Kim, Jeong Ho; Kim, Hyung Jin; Han, Heon; Lee, Hong Lyeol; Kim, Kwang Ho; Suh, Chang Hae

    1999-01-01

    To evaluate the usefulness of contrast-enhanced dynamic MR imaging for differentiation of benign and malignant solitary pulmonary nodules (SPNs). Twenty-three patients with histologically or radiologically provened SPNs smaller than 40mm (14 benign, 9 malignant) underwent MR examination using the breath-hold fast multiplanar spoiled gradient echo (FMPSPGR) technique. Pre-enhancement MR examination was followed by serial scans obtained at one-minute intervals, beginning one-minute after the onset of bolus injection of paramagnetic contrast agent for a total of five scans. Signal intensities of SPNs were measured from pre- and post-contrast enhanced MR images and peak percentage increase in signal intensity (p%SI) was calculated. Mean percentage increase in signal intensity (m%SI) was also calculated and the time-m%SI curve was plotted. The enhancement patterns of SPNs were classified as homogeneous, peripheral rim-like, inhomogeneous, or no (or minimal) enhancement. We compared differences in p%SI, the pattern of the time-m%SI curve, and the pattern of enhancement between benign and malignant SPNs. On dynamic MR images, alignant SPNs (n=9) showed a significantly higher p%SI than benign SPNs (n=14) (malignant : mean 120.6, range 81.8-171.6; benign : mean 29.5, range 3.7-78.9)(p<0.0001). With 80 p%SI as the threshold for malignancy-positive, both sensitivity and specificity were 100%. The m%SI of malignant SPNs rapidly increased at one minute after enhancement and decreased gradually thereafter, whereas that of benign SPNs increased more slowly to form a plateau. Eighty-nine percent (8/9) of malignant SPNs showed homogeneous enhancement. In contrast, among benign SPNs, peripheral rim-like enhancement and no (or minimal) enhancement occurred in the same proportion of cases : 50%(7/14). The superb demonstration of different enhancement characteristics obtained using dynamic contrast-enhanced MR imaging is useful to discriminate malignant from benign SPNs

  17. Dependable Real-Time Systems

    Science.gov (United States)

    1991-09-30

    0196 or 413 545-0720 PI E-mail Address: krithi@nirvan.cs.umass.edu, stankovic(ocs.umass.edu Grant or Contract Title: Dependable Real - Time Systems Grant...Dependable Real - Time Systems " Grant or Contract Number: N00014-85-k-0398 L " Reporting Period: 1 Oct 87 - 30 Sep 91 , 2. Summary of Accomplishments ’ 2.1 Our...in developing a sound approach to scheduling tasks in complex real - time systems , (2) developed a real-time operating system kernel, a preliminary

  18. Contrast-enhanced ultrasound for extrahepatic lesions: preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Thorelius, Lars E-mail: lars@thorelius.com

    2004-06-01

    Ultrasound imaging (US) is a convenient, inexpensive and non-invasive investigation. Its use is limited by low sensitivity in the detection of a number of parenchymal lesions, especially those produced by trauma, such as infarctions. Contrast enhancement with SonoVue{sup [reg]} improves the sensitivity of ultrasound in the detection and characterization of focal liver lesions to such an extent, that it may replace computed tomography (CT) and magnetic resonance imaging (MRI). Preliminary experience suggests that SonoVue-enhanced sonography may be useful in the detection of lesions in which blood flow is severely reduced as compared to surrounding parenchyma, such as infarctions, lacerations, hematomas, necrotic tissue and non-vascular cysts, especially in the spleen, kidney and pancreas. This technique can also rule out occlusion of the superior mesenteric, splenic and portal veins, and dilation of the biliary tree. Clinical trials comparing contrast-enhanced sonography with contrast-enhanced computed tomography are warranted to establish the role of this inexpensive and non-invasive technique in the routine work-up of patients with abdominal trauma or presenting with sudden flank pain.

  19. LabVIEW Real-Time

    CERN Multimedia

    CERN. Geneva; Flockhart, Ronald Bruce; Seppey, P

    2003-01-01

    With LabVIEW Real-Time, you can choose from a variety of RT Series hardware. Add a real-time data acquisition component into a larger measurement and automation system or create a single stand-alone real-time solution with data acquisition, signal conditioning, motion control, RS-232, GPIB instrumentation, and Ethernet connectivity. With the various hardware options, you can create a system to meet your precise needs today, while the modularity of the system means you can add to the solution as your system requirements grow. If you are interested in Reliable and Deterministic systems for Measurement and Automation, you will profit from this seminar. Agenda: Real-Time Overview LabVIEW RT Hardware Platforms - Linux on PXI Programming with LabVIEW RT Real-Time Operating Systems concepts Timing Applications Data Transfer

  20. Hepatobiliary contrast agents for contrast-enhanced MRI of the liver: properties, clinical development and applications

    International Nuclear Information System (INIS)

    Reimer, Peter; Schneider, Guenter; Schima, Wolfgang

    2004-01-01

    Hepatobiliary contrast agents with uptake into hepatocytes followed by variable biliary excretion represent a unique class of cell-specific MR contrast agents. Two hepatobiliary contrast agents, mangafodipir trisodium and gadobenate dimeglumine, are already clinically approved. A third hepatobiliary contrast agent, Gd-EOB-DTPA, is under consideration. The purpose of this review is to provide an overview on the properties, clinical development and application of these three hepatobiliary contrast agents. Bolus injectable paramagnetic hepatobiliary contrast agents combine established features of extracellular agents with the advantages of hepatocyte specificity. The detection and characterisation of focal liver disease appears to be improved compared to unenhanced MRI, MRI with unspecific contrast agents and contrast-enhanced CT. To decrease the total time spent by a patient in the MR scanner, it is advisable to administer the agent immediately after acquisition of unenhanced T1-w MRI. After infusion or bolus injection (with dynamic FS-T1-w 2D or 3D GRE) of the contrast agent, moderately and heavily T2w images are acquired. Post-contrast T1-w MRI is started upon completion of T2-w MRI for mangafodipir trisodium and Gd-EOB-DTPA as early as 20 min following injection, while gadobenate dimeglumine scans are obtained >60 min following injection. Post-contrast acquisition techniques with near isotropic 3D pulse sequences with fat saturation parallel the technical progress made by MSCT combined with an unparalleled improvement in tumour-liver contrast. The individual decision that hepatobiliary contrast agent one uses is partly based on personal preferences. No comparative studies have been conducted comparing the advantages or disadvantages of all three agents directly against each other. (orig.)

  1. Model-based, semiquantitative and time intensity curve shape analysis of dynamic contrast-enhanced MRI: a comparison in patients undergoing antiangiogenic treatment for recurrent glioma

    NARCIS (Netherlands)

    Lavini, Cristina; Verhoeff, Joost J. C.; Majoie, Charles B.; Stalpers, Lukas J. A.; Richel, Dick J.; Maas, Mario

    2011-01-01

    To compare time intensity curve (TIC)-shape analysis of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) data with model-based analysis and semiquantitative analysis in patients with high-grade glioma treated with the antiangiogenic drug bevacizumab. Fifteen patients had a pretreatment

  2. Concepts of real time and semi-real time material control

    International Nuclear Information System (INIS)

    Lovett, J.E.

    1975-01-01

    After a brief consideration of the traditional material balance accounting on an MBA basis, this paper explores the basic concepts of real time and semi-real time material control, together with some of the major problems to be solved. Three types of short-term material control are discussed: storage, batch processing, and continuous processing. (DLC)

  3. Real Time Systems

    DEFF Research Database (Denmark)

    Christensen, Knud Smed

    2000-01-01

    Describes fundamentals of parallel programming and a kernel for that. Describes methods for modelling and checking parallel problems. Real time problems.......Describes fundamentals of parallel programming and a kernel for that. Describes methods for modelling and checking parallel problems. Real time problems....

  4. Real time expert systems

    International Nuclear Information System (INIS)

    Asami, Tohru; Hashimoto, Kazuo; Yamamoto, Seiichi

    1992-01-01

    Recently, aiming at the application to the plant control for nuclear reactors and traffic and communication control, the research and the practical use of the expert system suitable to real time processing have become conspicuous. In this report, the condition for the required function to control the object that dynamically changes within a limited time is presented, and the technical difference between the real time expert system developed so as to satisfy it and the expert system of conventional type is explained with the actual examples and from theoretical aspect. The expert system of conventional type has the technical base in the problem-solving equipment originating in STRIPS. The real time expert system is applied to the fields accompanied by surveillance and control, to which conventional expert system is hard to be applied. The requirement for the real time expert system, the example of the real time expert system, and as the techniques of realizing real time processing, the realization of interruption processing, dispersion processing, and the mechanism of maintaining the consistency of knowledge are explained. (K.I.)

  5. The value of contrast-enhanced CT scan in prediction of development of contusional hemorrhage

    International Nuclear Information System (INIS)

    Yokoyama, Kazuhiro; Kyoi, Kikuo; Sakaki, Toshisuke; Kinugawa, Kazuhiko; Morimoto, Tetsuya

    1983-01-01

    It is often experienced that even if there are no significant findings on the initial plain CT scan in the patient with cerebral contusion, the patient has thereafter a serious clinical course and requires emergency operation for so-called contusional hemorrhage. In order to predict of the development of contusional hemorrhage we performed contrast-enhanced CT scan at the time of patient's arrival within 12 hours after injury, if there was cerebral contusion on the initial plain CT scan, and repeated plain CT scan 24 hours after the contrast-enhanced CT scan. If enhancement was demonstrated on the contrastenhanced CT scan, we predicted the development of contusional hemorrhage and if not demonstrated, we predicted no more development of contusional hemorrhage and then we studied the correlation between the prediction and the plain CT 24 hours after the contrast-enhanced CT scan. The results were as follows: 1) The prediction was correct in 13 cases out of 16 cases in which the development of contusional hemorrhage was observed. In 18 cases where no development of contusional hemorrhage was observed, the prediction was correct without exception. 2) Most of the cases in which enhancement was demonstrated were ones examined not before 3 hours after injury. 3) The extent of enhancement shown on contrastenhanced CT scan was well consistent with that of contusional hemorrhage on the plain CT scan 24 hours after the contrast-enhanced CT scan. From these results, the contrast-enhanced CT scan in acute stage of head injury was considered to by very useful in prediction of the development of contusional hemorrhage. (author)

  6. Detection of cavernous transformation of the portal vein by contrast-enhanced ultrasound.

    Science.gov (United States)

    Hwang, Misun; Thimm, Matthew A; Guerrerio, Anthony L

    2018-06-01

    Cavernous transformation of the portal vein can be missed on color Doppler exam or arterial phase cross-sectional imaging due to their slow flow and delayed enhancement. Contrast-enhanced ultrasound (CEUS) offers many advantages over other imaging techniques and can be used to successfully detect cavernous transformations of the portal vein. A 10-month-old female was followed for repeat episodes of hematemesis. Computed tomography angiography (CTA) and magnetic resonance arteriogram (MRA) and portal venography were performed. Color Doppler exam of the portal vein was performed followed by administration of Lumason, a microbubble US contrast agent. Magnetic resonance arteriogram, CTA, and color Doppler exam at the time of initial presentation was unremarkable without obvious vascular malformation within the limits of motion degraded exam. At 8-month follow-up, esophagogastroduodenoscopy revealed a vascular malformation in the distal esophagus which was sclerosed. At 6 month after sclerosis of the lesion, portal venography revealed occlusion of the portal vein with extensive collateralization. Color Doppler revealed subtle hyperarterialization and periportal collaterals. CEUS following color Doppler exam demonstrated extensive enhancement of periportal collaterals. Repeat color Doppler after contrast administration demonstrated extensive Doppler signal in the collateral vessels, suggestive of cavernous transformation. We describe a case of cavernous transformation of the portal vein missed on initial color Doppler, CTA and MRA, but detected with contrast-enhanced ultrasound technique.

  7. Prototype real-time baseband signal combiner. [deep space network

    Science.gov (United States)

    Howard, L. D.

    1980-01-01

    The design and performance of a prototype real-time baseband signal combiner, used to enhance the received Voyager 2 spacecraft signals during the Jupiter flyby, is described. Hardware delay paths, operating programs, and firmware are discussed.

  8. Confident Diagnosis of Bronchobiliary Fistula Using Contrast-Enhanced Magnetic Resonance Cholangiography

    Energy Technology Data Exchange (ETDEWEB)

    Karabulut, Nevzat; Cakmak, Vefa; Kiter, Go ksel [Pamukkale University Medical Center, Denizli (Turkmenistan)

    2010-08-15

    We report the utility of contrast-enhanced magnetic resonance cholangiography (MRC) using gadoxetic acid (Gd-EOB-DTPA) in the diagnosis of bronchobiliary fistula associated with liver hydatid cyst. Contrast-enhanced MRC clearly delineated the leakage of contrast agent from the biliary duct and its communication with the bronchial tree. Providing functional information about physiologic or pathologic biliary flow in addition to the display of biliary anatomy, contrast enhanced MRC stands as a robust technique in confidently detecting bronchobiliary fistula and bile leaks

  9. Cranial CT revisited: do we really need contrast enhancement?

    International Nuclear Information System (INIS)

    Demaerel, P.; Buelens, C.; Wilms, G.; Baert, A.L.

    1998-01-01

    The aim of this study was to define guidelines for intravenous contrast administration in cranial CT, as currently there are no recent guidelines based on a large series of patients. In 1900 consecutive patients (1480 adults and 420 children) pre- and post-contrast scan was analysed in order to assess the contribution of contrast enhancement to the diagnosis. The findings were grouped according to whether abnormalities were seen on the pre- and/or post-contrast scan, or whether no abnormalities were seen at all. Sensitivity, specificity, positive predictive value, negative predictive value and accurracy of a pre-contrast scan were used to determine validity. Intravenous contrast enhancement only contributes to the diagnosis if a suspicious abnormality is seen on the unenhanced scan or in the appropriate clinical setting (33.6 %). In the remaining patients (65.6 %) there is no diagnostic contribution, except for a small number of abnormalities (0.8 %). These are often anatomical variants and have no therapeutic impact. The number of contrast-enhanced cranial CT examinations can significantly be reduced by using four general guidelines for contrast administration resulting in considerable cost savings without affecting the quality of service to the patient. These guidelines are defined by the clinical findings/presentation or by the findings on the unenhanced scan. The number of contrast-related complications will be reduced, which may have medicolegal implications. These guidelines can be applied in any radiology department. (orig.) (orig.)

  10. Optimization of Region of Interest Drawing for Quantitative Analysis: Differentiation Between Benign and Malignant Breast Lesions on Contrast-Enhanced Sonography.

    Science.gov (United States)

    Nakata, Norio; Ohta, Tomoyuki; Nishioka, Makiko; Takeyama, Hiroshi; Toriumi, Yasuo; Kato, Kumiko; Nogi, Hiroko; Kamio, Makiko; Fukuda, Kunihiko

    2015-11-01

    This study was performed to evaluate the diagnostic utility of quantitative analysis of benign and malignant breast lesions using contrast-enhanced sonography. Contrast-enhanced sonography using the perflubutane-based contrast agent Sonazoid (Daiichi Sankyo, Tokyo, Japan) was performed in 94 pathologically proven palpable breast mass lesions, which could be depicted with B-mode sonography. Quantitative analyses using the time-intensity curve on contrast-enhanced sonography were performed in 5 region of interest (ROI) types (manually traced ROI and circular ROIs of 5, 10, 15, and 20 mm in diameter). The peak signal intensity, initial slope, time to peak, positive enhancement integral, and wash-out ratio were investigated in each ROI. There were significant differences between benign and malignant lesions in the time to peak (P benign and malignant lesions in the time to peak (P benign and malignant breast lesions. © 2015 by the American Institute of Ultrasound in Medicine.

  11. Toward real-time regional earthquake simulation II: Real-time Online earthquake Simulation (ROS) of Taiwan earthquakes

    Science.gov (United States)

    Lee, Shiann-Jong; Liu, Qinya; Tromp, Jeroen; Komatitsch, Dimitri; Liang, Wen-Tzong; Huang, Bor-Shouh

    2014-06-01

    We developed a Real-time Online earthquake Simulation system (ROS) to simulate regional earthquakes in Taiwan. The ROS uses a centroid moment tensor solution of seismic events from a Real-time Moment Tensor monitoring system (RMT), which provides all the point source parameters including the event origin time, hypocentral location, moment magnitude and focal mechanism within 2 min after the occurrence of an earthquake. Then, all of the source parameters are automatically forwarded to the ROS to perform an earthquake simulation, which is based on a spectral-element method (SEM). A new island-wide, high resolution SEM mesh model is developed for the whole Taiwan in this study. We have improved SEM mesh quality by introducing a thin high-resolution mesh layer near the surface to accommodate steep and rapidly varying topography. The mesh for the shallow sedimentary basin is adjusted to reflect its complex geometry and sharp lateral velocity contrasts. The grid resolution at the surface is about 545 m, which is sufficient to resolve topography and tomography data for simulations accurate up to 1.0 Hz. The ROS is also an infrastructural service, making online earthquake simulation feasible. Users can conduct their own earthquake simulation by providing a set of source parameters through the ROS webpage. For visualization, a ShakeMovie and ShakeMap are produced during the simulation. The time needed for one event is roughly 3 min for a 70 s ground motion simulation. The ROS is operated online at the Institute of Earth Sciences, Academia Sinica (http://ros.earth.sinica.edu.tw/). Our long-term goal for the ROS system is to contribute to public earth science outreach and to realize seismic ground motion prediction in real-time.

  12. Contrast-enhanced ultra-high-field liver MRI: A feasibility trial

    Energy Technology Data Exchange (ETDEWEB)

    Umutlu, Lale, E-mail: Lale.Umutlu@uk-essen.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Bitz, Andreas K.; Maderwald, Stefan; Orzada, Stephan; Kinner, Sonja; Kraff, Oliver; Brote, Irina; Ladd, Susanne C.; Schroeder, Tobias; Forsting, Michael; Antoch, Gerald; Ladd, Mark E. [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Quick, Harald H. [Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Institute of Medical Physics, University Nuernberg-Erlangen (Germany); Lauenstein, Thomas C. [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany)

    2013-05-15

    The aim of this study was to investigate the feasibility of dynamic contrast-enhanced 7 T MRI of the liver using an eight-channel radiofrequency (RF) transmit/receive body-coil. 16 healthy subjects were examined on a 7 T MR system utilizing a custom-built eight-channel RF body-coil suitable for RF-shimming. The following data were acquired: (1) steady state free precession imaging, (2) T2w turbo spin echo imaging, (3) T1w in and opposed-phase imaging, (4) T1w 3D FLASH images pre-contrast and in arterial, portal-venous and venous phase and (5) a fat-saturated pre- and post-contrast 2D FLASH sequence. Visual evaluation of (1) the delineation of liver vasculature, (2) the overall image quality, and (3) artifact presence and consequent image impairment was performed. SNR of the liver parenchyma was measured for the contrast-enhanced 2D and 3D FLASH sequences. For statistical analysis, a Wilcoxon-Rank Test was used. Best delineation of non-enhanced liver vasculature and overall image quality was found for 2D FLASH MRI, with only slight improvement in vessel conspicuity after the application of contrast media. T2-weighted TSE imaging remained strongly impaired, falling short of diagnostic relevance and precluding a clinical application. Our results demonstrate the feasibility and diagnostic potential of dedicated contrast-enhanced 7 T liver MRI as well as the potential for non-contrast-enhanced angiographic application.

  13. Detection of vascularity in wrist tenosynovitis: power doppler ultrasound compared with contrast-enhanced grey-scale ultrasound.

    Science.gov (United States)

    Klauser, Andrea S; Franz, Magdalena; Arora, Rohit; Feuchtner, Gudrun M; Gruber, Johann; Schirmer, Michael; Jaschke, Werner R; Gabl, Markus F

    2010-01-01

    We sought to assess vascularity in wrist tenosynovitis by using power Doppler ultrasound (PDUS) and to compare detection of intra- and peritendinous vascularity with that of contrast-enhanced grey-scale ultrasound (CEUS). Twenty-six tendons of 24 patients (nine men, 15 women; mean age ± SD, 54.4 ± 11.8 years) with a clinical diagnosis of tenosynovitis were examined with B-mode ultrasonography, PDUS, and CEUS by using a second-generation contrast agent, SonoVue (Bracco Diagnostics, Milan, Italy) and a low-mechanical-index ultrasound technique. Thickness of synovitis, extent of vascularized pannus, intensity of peritendinous vascularisation, and detection of intratendinous vessels was incorporated in a 3-score grading system (grade 0 to 2). Interobserver variability was calculated. With CEUS, a significantly greater extent of vascularity could be detected than by using PDUS (P < 0.001). In terms of peri- and intratendinous vessels, CEUS was significantly more sensitive in the detection of vascularization compared with PDUS (P < 0.001). No significant correlation between synovial thickening and extent of vascularity could be found (P = 0.089 to 0.097). Interobserver reliability was calculated to be excellent when evaluating the grading score (κ = 0.811 to 1.00). CEUS is a promising tool to detect tendon vascularity with higher sensitivity than PDUS by improved detection of intra- and peritendinous vascularity.

  14. Accuracy of Ultrasonography and Rectal Palpation in the Diagnosis of Silent Heat in Cows Compared to Plasma Progesterone Concentration

    International Nuclear Information System (INIS)

    Zdunczyk, S.; Janowski, T.; Ras, A.; Baranski, W.

    2009-01-01

    The study was carried out on five dairy herds in the North-East Poland. The cows, which showed no visible oestrus signs until day 60 postpartum, were examined by ultrasonography and rectal palpation twice, at a 10-d interval. A real-time, B-mode scanner with a 5 MHz probe was used. The plasma progesterone concentration was determined using RIA. A high progesterone level on the first examination, but low on the second, or low on the first and high on the second examination were interpreted as a silent heat. Based on the progesterone values, silent heat was diagnosed in 145 anoestrous cows, whereas ultrasonographically, 106 cows were found to have silent heat. The accuracy of the ultrasonography and rectal palpation in the diagnosis of silent heat in cows was 89.0 % and 69.7 %, respectively (P ≤ 0.05). For the diagnosis of the corpus luteum, the sensitivity and specificity of the ultrasonography was 94.7 % and 84.0 %, and for rectal palpation 86.2 % and 70.3 %, respectively (P ≤ 0.05). Our results showed that ultrasonography is a useful tool in the diagnosis of silent heat in cows. (authors)

  15. Emergency surgeon-performed hepatobiliary ultrasonography.

    LENUS (Irish Health Repository)

    Kell, M R

    2012-02-03

    BACKGROUND: Acute hepatobiliary pathology is a common general surgical emergency referral. Diagnosis requires imaging of the biliary tree by ultrasonography. The accuracy and impact of surgeon-performed ultrasonography (SUS) on the diagnosis of emergent hepatobiliary pathology was examined. METHODS: A prospective study, over a 6-month period, enrolled all patients with symptoms or signs of acute hepatobiliary pathology. Patients provided informed consent and underwent both SUS and standard radiology-performed ultrasonography (RUS). SUS was performed using a 2-5-MHz broadband portable ultrasound probe by two surgeons trained in ultrasonography, and RUS using a 2-5-MHz fixed unit. SUS results were correlated with those of RUS and pathological diagnoses. RESULTS: Fifty-three consecutive patients underwent 106 ultrasonographic investigations. SUS agreed with RUS in 50 (94.3 per cent) of 53 patients. SUS accurately detected cholelithiasis in all but two cases and no patient was inaccurately diagnosed as having cholelithiasis at SUS (95.2 per cent sensitivity and 100 per cent specificity). As an overall complementary diagnostic tool SUS provided the correct diagnosis in 96.2 per cent of patients. Time to scan was significantly shorter following SUS (3.1 versus 12.0 h, P < 0.05). CONCLUSION: SUS provides a rapid and accurate diagnosis of emergency hepatobiliary pathology and may contribute to the emergency management of hepatobiliary disease.

  16. Dynamic contrast-enhanced MRI examination of atherosclerotic plaques: an animal study using rabbit model

    International Nuclear Information System (INIS)

    Li Mingli; Sun Jie; Chang Xiaoyan; Jin Zhengyu

    2011-01-01

    Objective: The enhanced patterns of atherosclerotic plaque on dynamic contrast- enhanced MRI have not been well studied. The aim of this study was to explore the patterns of plaque enhancement and their underlying mechanism by using dynamic contrast-enhanced MRI (DCE-MRI). Methods: Atherosclerotic plaques were induced in the aorta of 12 New Zealand White rabbits by a combination of endothelial denudation and high-cholesterol diet. Ten to sixteen weeks after surgery, DCE- MRI was performed with a fast spin echo T 1 weighted sequence. Thirty-five phases of images were obtained at 71-second intervals. Gd-DTPA was injected coincident with the third scan via marginal ear vein. Specimens were harvested within 12 hours after imaging for HE staining and CD31 immunohistochemical staining which was used to highlight neo-vessels. Plaque enhancement patterns were studied and compared with histological findings. Signal intensity of each plaque section was normalized to pre-contrast signal intensity of psoas muscle, after which signal intensity versus time curve was drawn. Pearson correlation coefficient was used to reveal association between histological neo-vessel count and descriptive parameters derived from signal intensity versus time curve. Results: Plaques were significantly enhanced by Gd-DTPA. Enhancement patterns could be described as 'fast-in and slow-out'. Differences in patterns of enhancement were observed between tissues, with fibrous tissue enhanced more than lipid aggregation and leukocyte foci. Peak enhancement (1.05±0.30), initial slope (0.82±0.28) and area under the curve at early phase (4.97± 1.67) derived from signal intensity-time curve had significant correlations with neo-vessel count (117.7± 93.3) (r=0.553, 0.468, 0.554 respectively, P<0.05). Conclusions: The enhanced patterns of atherosclerotic plaque by Gd-DTPA were 'fast- in and slow-out'. Neovascularization, increased endothelial permeability and extracellular matrix may be the reasons for

  17. High-resolution real-time sonography and MR imaging in assessment of osteocartilaginous exostoses

    International Nuclear Information System (INIS)

    Prayer, L.M.; Kropej, D.H.; Wimberger, D.M.; Wurnig, C.F.; Kramer, J.; Kainberger, F.M.; Braun, O.H.; Ritschl, P.W.; Imhof, H.

    1991-01-01

    High-resolution real-time ultrasonography (US) and MR imaging, using both spin-echo (SE) and gradient-echo (GE) sequences, were performed prospectively in 14 patients with solitary osteocartilaginous exostoses to assess cartilage cap thickness and bursa formation. Results were compared to surgical and histopathologic findings in all cases. Both US and MR imaging were useful in evaluating exostotic cartilage cap thickness, which is supposed to be the most reliable sign of malignant transformation. Hyaline cartilage matrix had distinctive features in US and MR imaging caused by its specific histologic composition. The formation of bursae over the protruding exostoses, which results in pain and clinically could raise the suspicion of growth and malignant transformation, was demonstrated best using GE sequences. MR imaging was thus superior to US in the detection of bursa formation. (orig.)

  18. High-resolution real-time sonography and MR imaging in assessment of osteocartilaginous exostoses

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, L.M.; Kropej, D.H.; Wimberger, D.M.; Wurnig, C.F.; Kramer, J.; Kainberger, F.M.; Braun, O.H.; Ritschl, P.W.; Imhof, H. (Vienna Univ. (Austria). Depts. of Radiology, Orthopedic Surgery, Pathology, and the MR Inst.)

    1991-09-01

    High-resolution real-time ultrasonography (US) and MR imaging, using both spin-echo (SE) and gradient-echo (GE) sequences, were performed prospectively in 14 patients with solitary osteocartilaginous exostoses to assess cartilage cap thickness and bursa formation. Results were compared to surgical and histopathologic findings in all cases. Both US and MR imaging were useful in evaluating exostotic cartilage cap thickness, which is supposed to be the most reliable sign of malignant transformation. Hyaline cartilage matrix had distinctive features in US and MR imaging caused by its specific histologic composition. The formation of bursae over the protruding exostoses, which results in pain and clinically could raise the suspicion of growth and malignant transformation, was demonstrated best using GE sequences. MR imaging was thus superior to US in the detection of bursa formation. (orig.).

  19. Time-delayed contrast-enhanced MRI improves detection of brain metastases and apparent treatment volumes.

    Science.gov (United States)

    Kushnirsky, Marina; Nguyen, Vinh; Katz, Joel S; Steinklein, Jared; Rosen, Lisa; Warshall, Craig; Schulder, Michael; Knisely, Jonathan P S

    2016-02-01

    Contrast-enhanced MRI is the preeminent diagnostic test for brain metastasis (BM). Detection of BMs for stereotactic radiosurgery (SRS) planning may improve with a time delay following administration of a high-relaxivity agent for 1.5-T and 3-T imaging systems. Metastasis detection with time-delayed MRI was evaluated in this study. Fifty-three volumetric MRI studies from 38 patients undergoing SRS for BMs were evaluated. All studies used 0.1-mmol/kg gadobenate dimeglumine (MultiHance; Bracco Diagnostics) immediately after injection, followed by 2 more axial T1-weighted sequences after 5-minute intervals (final image acquisition commenced 15 minutes after contrast injection). Two studies were motion limited and excluded. Two hundred eighty-seven BMs were identified. The studies were randomized and examined separately by 3 radiologists, who were blinded to the temporal sequence. Each radiologist recorded the number of BMs detected per scan. A Wilcoxon signed-rank test compared BM numbers between scans. One radiologist determined the scan on which BMs were best defined. All confirmed, visible tumors were contoured using iPlan RT treatment planning software on each of the 3 MRI data sets. A linear mixed model was used to analyze volume changes. The interclass correlations for Scans 1, 2, and 3 were 0.7392, 0.7951, and 0.7290, respectively, demonstrating excellent interrater reliability. At least 1 new lesion was detected in the second scan as compared with the first in 35.3% of subjects (95% CI 22.4%-49.9%). The increase in BM numbers between Scans 1 and 2 ranged from 1 to 10. At least 1 new lesion was detected in the third scan as compared with the second in 21.6% of subjects (95% CI 11.3%-35.3%). The increase in BM numbers between Scans 2 and 3 ranged from 1 to 9. Between Scans 1 and 3, additional tumors were seen on 43.1% of scans (increase ranged from 1 to 14). The median increase in tumor number for all comparisons was 1. There was a significant increase in number

  20. Challenges in contrast-enhanced spectral mammography interpretation: artefacts lexicon.

    Science.gov (United States)

    Yagil, Y; Shalmon, A; Rundstein, A; Servadio, Y; Halshtok, O; Gotlieb, M; Sklair-Levy, M

    2016-05-01

    To review and describe commonly encountered artefacts in contrast-enhanced spectral mammography (CESM). This retrospective study included 200 women who underwent CESM examinations for screening and diagnostic purposes. Analysis was performed on the image data sets of these women, comprising of a total of 774 subtracted images. Images were reviewed with focus on the presence of four artefacts: rim ("breast within breast"), ripple (black and white lines), axillary line, and skin-line enhancement (skin-line highlighting). Statistical cross-correlation and association with acquisition parameters (tube current, tube voltage, compression force, breast thickness, paddle size) was compared using Fisher's exact test and t-test. The rim artefact was highly common (97-99%) in every projection. The ripple artefact was increasingly more common on the oblique projections (80-82%) and found to be associated with higher breast thickness values. The axillary line artefact was detected only on oblique projections (63%) and associated with the use of a small compression paddle. The skin-line enhancement artefact was seen in 19-46% of projections. None of the artefacts interfered with image interpretation. Two main artefacts commonly seen on CESM are rim and ripple artefacts. They do not hamper with image interpretation. It is important to be aware of them and prevent misinterpretation of these artefacts as real breast pathology. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  1. Contrast enhancement pattern in MR imaging of acute cerebral infarction

    International Nuclear Information System (INIS)

    Kim, Jong Deok; Cho, Mee Young; Lee, Chae Guk; Song, Dong Hoon

    1994-01-01

    To present the enhancement pattern of acute cerebral or cerebellar cortical infarctions aged 1-3 days on MR. Contrast-enhanced MR images of 26 patients with acute cerebral or cerebellar ischemic events were retrospectively reviewed. MR was performed within 3 days after ictus. Contrast enhancement in the area of infarction was observed in 61.5% (16/26) on MR. Of these 50% (13/26) showed non-parenchymal enhancement (NPE) representing either vascular or leptomeningeal enhancement, 7.7% (2/26) showed parenchymal enhancement (PE), and 2.8% (1/26) showed both NPE and PE. The earliest enhancement was seen in images obtained 12 hours after the onset of symptoms and appeared as NPE. One patient showed NPE without apparent high signal intensity at the corresponding area on T2-weighted images. In 38.5% (10/26), there was no enhancement. Contrast-enhanced MR imaging may be needed in acute ischemic infarction, because NPE may be seen as the earliest MR finding of acute cortical infraction aged 1-3 days

  2. Contrast enhancement pattern in MR imaging of acute cerebral infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Deok; Cho, Mee Young; Lee, Chae Guk; Song, Dong Hoon [Inje University College of Medicine, Pusan (Korea, Republic of)

    1994-08-15

    To present the enhancement pattern of acute cerebral or cerebellar cortical infarctions aged 1-3 days on MR. Contrast-enhanced MR images of 26 patients with acute cerebral or cerebellar ischemic events were retrospectively reviewed. MR was performed within 3 days after ictus. Contrast enhancement in the area of infarction was observed in 61.5% (16/26) on MR. Of these 50% (13/26) showed non-parenchymal enhancement (NPE) representing either vascular or leptomeningeal enhancement, 7.7% (2/26) showed parenchymal enhancement (PE), and 2.8% (1/26) showed both NPE and PE. The earliest enhancement was seen in images obtained 12 hours after the onset of symptoms and appeared as NPE. One patient showed NPE without apparent high signal intensity at the corresponding area on T2-weighted images. In 38.5% (10/26), there was no enhancement. Contrast-enhanced MR imaging may be needed in acute ischemic infarction, because NPE may be seen as the earliest MR finding of acute cortical infraction aged 1-3 days.

  3. Contrast-enhanced MR 3D angiography in the assessment of brain AVMs

    International Nuclear Information System (INIS)

    Unlu, Ercument; Temizoz, Osman; Albayram, Sait; Genchellac, Hakan; Hamamcioglu, M. Kemal; Kurt, Imran; Demir, M. Kemal

    2006-01-01

    Background and purpose: Digital subtraction angiography (DSA) is the current reference standard for the diagnosis, assessment, and management of brain arteriovenous malformations (AVMs). The purpose of this study was to compare the diagnostic utility of three-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) and contrast-enhanced 3D MRA in patients with intracranial arteriovenous malformations (AVMs) in different sizes and locations. The AVM diagnosis was proved via DSA and almost half of the patients had also hematoma. Materials and methods: Two radiologists, experienced on neurovascular imaging and independent from each other, retrospectively reviewed two MRA techniques and DSA with regard to the assessment of feeding arteries, AVM nidus, and venous drainage patterns on 20 patients with 23 examinations by scoring system. Disagreements were resolved by consensus. Results: An excellent agreement between contrast-enhanced MRA and DSA was found in order to assess the numbers of arterial feeders and draining veins (Spearman r = 0.913, P < 0.001). The average scores in contrast-enhanced MRA for feeders, nidi, and drainers were respectively 2.26, 2.69, and 2.48, while in TOF-MRA they are 1.96, 1.35, and 0.89, respectively. Conclusion: Compared to TOF-MRA, 3D contrast-enhanced MRA is useful for visualization by subtraction technique of malformation components presented by hematoma or by haem product. On the other hand, for the cases presented by slow or complex flow that is especially in around or nidi or around the venous portion is also advantageous because of the independence from flow-related enhancement. Therapeutic effects were clearly demonstrated in three follow-up patients. A major limitation of this technique is the low spatial resolution. Since there is such a limitation, arterial feeder of a case with micro-AVM is not detected by contrast-enhanced MRA and nidus for the same case was observed retrospectively. In this respect, we

  4. Contrast-enhanced MR 3D angiography in the assessment of brain AVMs

    Energy Technology Data Exchange (ETDEWEB)

    Unlu, Ercument [Department of Radiology, Trakya University Medicine School, Edirne (Turkey)]. E-mail: drercument@yahoo.com; Temizoz, Osman [Department of Radiology, Trakya University Medicine School, Edirne (Turkey); Albayram, Sait [Department of Radiology, Istanbul University, Cerrahpasa Medicine School, Istanbul (Turkey); Genchellac, Hakan [Department of Radiology, Trakya University Medicine School, Edirne (Turkey); Hamamcioglu, M. Kemal [Department of Neurosurgery, Trakya University Medicine School, Edirne (Turkey); Kurt, Imran [Department of Biostatistics, Trakya University Medicine School, Edirne (Turkey); Demir, M. Kemal [Department of Radiology, Trakya University Medicine School, Edirne (Turkey)

    2006-12-15

    Background and purpose: Digital subtraction angiography (DSA) is the current reference standard for the diagnosis, assessment, and management of brain arteriovenous malformations (AVMs). The purpose of this study was to compare the diagnostic utility of three-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) and contrast-enhanced 3D MRA in patients with intracranial arteriovenous malformations (AVMs) in different sizes and locations. The AVM diagnosis was proved via DSA and almost half of the patients had also hematoma. Materials and methods: Two radiologists, experienced on neurovascular imaging and independent from each other, retrospectively reviewed two MRA techniques and DSA with regard to the assessment of feeding arteries, AVM nidus, and venous drainage patterns on 20 patients with 23 examinations by scoring system. Disagreements were resolved by consensus. Results: An excellent agreement between contrast-enhanced MRA and DSA was found in order to assess the numbers of arterial feeders and draining veins (Spearman r = 0.913, P < 0.001). The average scores in contrast-enhanced MRA for feeders, nidi, and drainers were respectively 2.26, 2.69, and 2.48, while in TOF-MRA they are 1.96, 1.35, and 0.89, respectively. Conclusion: Compared to TOF-MRA, 3D contrast-enhanced MRA is useful for visualization by subtraction technique of malformation components presented by hematoma or by haem product. On the other hand, for the cases presented by slow or complex flow that is especially in around or nidi or around the venous portion is also advantageous because of the independence from flow-related enhancement. Therapeutic effects were clearly demonstrated in three follow-up patients. A major limitation of this technique is the low spatial resolution. Since there is such a limitation, arterial feeder of a case with micro-AVM is not detected by contrast-enhanced MRA and nidus for the same case was observed retrospectively. In this respect, we

  5. Environmental Measurement-While-Drilling system for real-time field screening of contaminants

    International Nuclear Information System (INIS)

    Lockwood, G.J.; Normann, R.A.; Bishop, L.B.; Floran, R.J.; Williams, C.V.

    1995-01-01

    Sampling during environmental drilling is essential to fully characterize the spatial distribution and migration of near surface contaminants. However, the analysis of these samples is not only expensive, but can take weeks or months when sent to an off-site laboratory. In contrast, measurement-while-drilling (MWD) screening capability could save money and valuable time by quickly distinguishing between contaminated and uncontaminated areas. Real-time measurements provided by a MVM system would enable on-the-spot decisions to be made regarding sampling strategies, enhance worker safety, and provide the added flexibility of being able to ''steer'' the drill bit in or out hazardous zones. During measurement-while-drilling, down-hole sensors are located behind the drill bit and linked by a rapid data transmission system to a computer at the surface. As drilling proceeds, data are collected on the nature and extent of the subsurface contamination in real-time. The down-hole sensor is a Geiger-Mueller tube (GMT) gamma radiation detector. In addition to the GMT signal, the MWD system monitors these required down-hole voltages and two temperatures associated with the detector assembly. The Gamma Ray Detection System (GRDS) and electronics package are discussed in as well as the results of the field test. Finally, our conclusions and discussion of future work are presented

  6. Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer

    International Nuclear Information System (INIS)

    Tateishi, Ukihide; Maeda, Tetsuo; Morimoto, Tsuyoshi; Miyake, Mototaka; Arai, Yasuaki; Kim, E.E.

    2007-01-01

    The purpose of the present study was to determine the diagnostic accuracy of non-enhanced CT and contrast-enhanced CT in integrated PET/CT studies for preoperative nodal staging of rectal cancer. Retrospective analysis was performed in 53 patients with pathologically proven rectal cancer who had been referred for preoperative staging. All patients underwent integrated PET/CT consisting of non-enhanced and contrast-enhanced CT followed by whole-body fluorine-18-fluorodeoxyglucose ([ 18 F]FDG) PET. Both non-enhanced and contrast-enhanced PET/CT images were evaluated separately by two observers in consensus. The reference standard was histopathologic results. For nodal staging of rectal cancer, we compared diagnostic accuracy on a per-patient basis between the two modalities. Nodal staging was correctly determined with non-enhanced studies in 37 patients (70%) and with contrast-enhanced studies in 42 patients (79%). On a per-patient basis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of regional lymph node staging were 85%, 68%, 83%, 72%, and 79%, respectively, with contrast-enhanced studies, and 85%, 42%, 73%, 62%, and 70%, respectively, with non-enhanced studies. The difference in the accuracy of nodal staging between the two modalities was not significant (p = 0.063). Compared with non-enhanced studies, contrast-enhanced studies determined more correctly the status of pararectal lymph nodes (p 0.002), internal iliac lymph nodes (p = 0.004), and obturator lymph nodes (p < 0.0001). Contrast-enhanced PET/CT is superior to non-enhanced PET/CT for precise definition of regional nodal status in rectal cancer. (orig.)

  7. A real-time monitoring system for night glare protection

    Science.gov (United States)

    Ma, Jun; Ni, Xuxiang

    2010-11-01

    When capturing a dark scene with a high bright object, the monitoring camera will be saturated in some regions and the details will be lost in and near these saturated regions because of the glare vision. This work aims at developing a real-time night monitoring system. The system can decrease the influence of the glare vision and gain more details from the ordinary camera when exposing a high-contrast scene like a car with its headlight on during night. The system is made up of spatial light modulator (The liquid crystal on silicon: LCoS), image sensor (CCD), imaging lens and DSP. LCoS, a reflective liquid crystal, can modular the intensity of reflective light at every pixel as a digital device. Through modulation function of LCoS, CCD is exposed with sub-region. With the control of DSP, the light intensity is decreased to minimum in the glare regions, and the light intensity is negative feedback modulated based on PID theory in other regions. So that more details of the object will be imaging on CCD and the glare protection of monitoring system is achieved. In experiments, the feedback is controlled by the embedded system based on TI DM642. Experiments shows: this feedback modulation method not only reduces the glare vision to improve image quality, but also enhances the dynamic range of image. The high-quality and high dynamic range image is real-time captured at 30hz. The modulation depth of LCoS determines how strong the glare can be removed.

  8. Real-time data collection technologies: Enhanced decision-making and cost savings January, 2005

    International Nuclear Information System (INIS)

    Rust, T.L.; Vu, H.Q.

    2006-01-01

    Hand-held computers, Geographic Information Systems (GIS), and wireless communication devices are rapidly replacing traditional methods for field monitoring and data collection. Although pencil and paper remain important means of data transcription, field technicians can now use Personal Digital Assistants (PDA) to record their field notes and monitoring data. As data are uploaded wirelessly from the field, decision-makers can view realtime reports and maps that identify sample locations and monitoring results. The combination of PDAs, wireless communications, and web-based GIS provides field personnel and decision-makers many benefits throughout the life cycle of a project, including improved data consistency, real-time transfer of data from field locations to centralized databases, input validation, elimination of transcription errors, and cost savings. Concerns have been expressed however, about investing in hardware, software, and training for a new technology. This paper, based on several years of experience using wireless technologies for dozens of projects, is focused specifically on two case studies. The first case study is a large lead removal site in the Midwest at which real-time data collection technologies were used throughout the project to collect thousands of data points. The second is the Hurricane Katrina/Rita emergency response requiring rapid data collection under extraordinary circumstances. At both sites, the use of real-time data collection technologies significantly improved the data management process which reduced overall costs and increased efficiency. These results could not have been achieved using traditional data collection procedures. The oral presentation will focus on the advantages and disadvantages of the real-time data collection technologies, lessons learned, and planning considerations. A live demonstration, following a typical data collection scenario in which data are collected and plotted on a GIS map in near real-time

  9. Contrast-Enhanced Ultrasound in Vascular Surgery

    DEFF Research Database (Denmark)

    Bredahl, Kim; Mestre, Xavier Marti; Coll, Ramon Vila

    2017-01-01

    modalities. Ultrasound has only challenged these methods in assessment of carotid disease, aortic aneurysms, venous insufficiency, and thromboembolism and in surveillance of in situ bypasses. These practice patterns may change with the introduction of second-generation ultrasound contrast agents which...... are easy to use, manageable, and safe. This topical review attempts to summarize and highlight the current evidence and future prospects for contrast-enhanced ultrasound in vascular surgery, with a particular focus on opportunities in carotid and lower limb arteriosclerotic disease and surveillance after...

  10. Real time production optimization

    Energy Technology Data Exchange (ETDEWEB)

    Saputelli, Luigi; Otavio, Joao; Araujo, Turiassu; Escorcia, Alvaro [Halliburton, Houston, TX (United States). Landmark Division

    2004-07-01

    Production optimization encompasses various activities of measuring, analyzing, modeling, prioritizing and implementing actions to enhance productivity of a field. We present a state-of-the-art framework for optimizing production on a continuous basis as new sensor data is acquired in real time. Permanently acquired data is modeled and analyzed in order to create predictive models. A model based control strategy is used to regulate well and field instrumentation. The optimum field operating point, which changes with time, satisfies the maximum economic return. This work is a starting point for further development in automatic, intelligent reservoir technologies which get the most out of the abilities of permanent, instrumented wells and remotely activated downhole completions. The strategy, tested with history-matched data from a compartmentalised giant field, proved to reduce operating costs while increasing oil recovery by 27% in this field. (author)

  11. Detection of liver metastases in cancer patients with geographic fatty infiltration of the liver: the added value of contrast-enhanced sonography

    International Nuclear Information System (INIS)

    Bartolotta, Tommaso Vincenzo; Taibbi, Adele; Picone, Dario; Anastasi, Andrea; Midiri, Massimo; Lagalla, Roberto

    2017-01-01

    The aim of this study is to assess the role of contrast-enhanced ultrasonography (CEUS) in the detection of liver metastases in cancer patients with geographic liver fatty deposition on greyscale ultrasonography (US). Thirty-seven consecutive cancer patients (24 women and 13 men; age, 33 to 80 years; mean, 58.1 years) with geographic liver fatty deposition, but without any detectable focal liver lesion on greyscale US, underwent sulphur hexafluoride-enhanced US. Two readers reported by consensus the presence, size, and location of any detected lesion. All patients underwent magnetic resonance imaging (MRI) as a confirmatory study. Sensitivity, specificity, positive and negative predictive values (PPV and NPV), and accuracy were calculated. Seven focal liver lesions (size, 4 to 10 mm; mean, 6.1 mm) were detected in 4/37 patients (10.8%): four metastases (size, 5 to 10 mm; mean, 6.7 mm) were detected both by CEUS and MRI, with one hemangioma and two cysts (size range, 4 to 6 mm; mean, 5.3 mm) detected by MRI only. In 1/37 patients (2.7%), CEUS misdiagnosed geographic fatty change as three metastases. In 32/37 patients (86.5%), no lesions were detected. Sensitivity, specificity, PPV, NPV, and accuracy of CEUS were 100% (95% confidence Interval [CI], 1.000 to 1.000), 97.1% (95% CI, 0.914 to 1.027), 75%, 100%, and 97.3%, respectively. No statistically significant differences were found between CEUS and MRI in the detection of focal liver lesions (P=0.480), whereas both of them performed better than baseline US (P<0.001). CEUS improves the detection of liver metastases in cancer patients with geographic liver fatty deposition on greyscale US

  12. Detection of liver metastases in cancer patients with geographic fatty infiltration of the liver: the added value of contrast-enhanced sonography

    Energy Technology Data Exchange (ETDEWEB)

    Bartolotta, Tommaso Vincenzo; Taibbi, Adele; Picone, Dario; Anastasi, Andrea; Midiri, Massimo; Lagalla, Roberto [Dept. of Radiology-Di.Bi.Med., University of Palermo, Palermo (Italy)

    2017-04-15

    The aim of this study is to assess the role of contrast-enhanced ultrasonography (CEUS) in the detection of liver metastases in cancer patients with geographic liver fatty deposition on greyscale ultrasonography (US). Thirty-seven consecutive cancer patients (24 women and 13 men; age, 33 to 80 years; mean, 58.1 years) with geographic liver fatty deposition, but without any detectable focal liver lesion on greyscale US, underwent sulphur hexafluoride-enhanced US. Two readers reported by consensus the presence, size, and location of any detected lesion. All patients underwent magnetic resonance imaging (MRI) as a confirmatory study. Sensitivity, specificity, positive and negative predictive values (PPV and NPV), and accuracy were calculated. Seven focal liver lesions (size, 4 to 10 mm; mean, 6.1 mm) were detected in 4/37 patients (10.8%): four metastases (size, 5 to 10 mm; mean, 6.7 mm) were detected both by CEUS and MRI, with one hemangioma and two cysts (size range, 4 to 6 mm; mean, 5.3 mm) detected by MRI only. In 1/37 patients (2.7%), CEUS misdiagnosed geographic fatty change as three metastases. In 32/37 patients (86.5%), no lesions were detected. Sensitivity, specificity, PPV, NPV, and accuracy of CEUS were 100% (95% confidence Interval [CI], 1.000 to 1.000), 97.1% (95% CI, 0.914 to 1.027), 75%, 100%, and 97.3%, respectively. No statistically significant differences were found between CEUS and MRI in the detection of focal liver lesions (P=0.480), whereas both of them performed better than baseline US (P<0.001). CEUS improves the detection of liver metastases in cancer patients with geographic liver fatty deposition on greyscale US.

  13. Diagnostic value of contrast-enhanced dynamic CT in predicting the malignancy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Song, Koun Sik; Lee, Eun Hye; Kim, Ji Hoon; Lee, Jin Seong; Lim, Tae Hwan

    1997-01-01

    To determine whether the maximal enhancement time in dynamic CT is different between benign and malignant solitary pulmonary nodules (SPN)s, and to evaluate the value of densitometry on dynamic CT in predicting the malignancy of SPN. Fifty-six patients with SPN of less than 4cm in diameter as seen on chest radiograph and SPN without benign pattern of calcification or fat, as seen on pre-enhance-ment spiral CT scans were included in this study. SPN with small cavitation sufficient to measure CT density, were also included. Thirty-four SPNs were diagnosed pathologically or radiologically as 20 malignant nodules and 14 benign nodules. Dynamic CT was performed by two techniques after injection of 50ml of nonionic contrast media at the rate of 2ml/sec. In 28 patients, incremental dynamic CT was performed before and of 15 seconds, 1 minute, 2 minutes, 3 minutes, and 4 minutes after injection of contrast media during shallow respiration. In 28 patients, double spiral CT was performed 2 minutes and 3 minutes after injection of contrast media during single breath hold. CT readings were taken at the central portion of SPNs, with a circular region of interest. The degree and time of maximal enhancement were recorded. In dynamic CT the maximal enhancement time of SPNs was not significantly different between malignant (2.73±1.27 minute) and benign nodules (2.56±1.24 minute). The enhancement of malignant nodules was significantly greater (21.42±12.17 HU) than of benign nodules (5.15±5.25 HU) (p<.0001). In dynamic CT of SPNs, there is no difference in maximal enhancement time between benign and malignant nodules;enhancement of the latter is significantly greater than that of the former. Maximal enhancement greater than 15 HU can be a good predictor of malignancy of SPNs

  14. Contrast-enhanced fast fluid-attenuated inversion recovery MR imaging in patients with brain tumors

    International Nuclear Information System (INIS)

    Kim, Chan Kyo; Na, Dong Gyu; Ryoo, Wook Jae; Byun Hong Sik; Yoon, Hye Kyung; Kim, Jong hyun

    2000-01-01

    To assess the feasibility of contrast-enhanced fast fluid-attenuated inversion recovery (fast FLAIR) MR imaging in patients with brain tumors. This study involved 31 patients with pathologically proven brain tumors and nine with clinically diagnosed metastases. In all patients, T2-weighted, fast FLAIR, images were visual contrast-enhanced T1-weighted MR images were obtained. Contrast-enhanced fast FLAIR images were visually compared with other MR sequences in terms of tumor conspicuity. In order to distinguish tumor and surrounding edema, contrast-enhanced fast FLAIR images were compared with fast FLAIR and T2-weighted images. The tumor-to- white matter contrast-to-noise ratios (CNRs), as demonstrated by T2-weighted, fast FLAIR, contrast-enhanced fast FLAIR and contrast-enhanced T1-weighted imaging, were quantitatively assessed and compared. For the visual assessment of tumor conspicuity, contrast-enhanced fast FLAIR image imaging superior to fast FLAIR in 60% of cases (24/40), and superior to T2-weighted in 70% (28/40). Contrast-enhanced fast FLAIR imaging was inferior to contrast-enhanced T1-weighted in 58% of cases (23/40). For distinguishing between tumor and surrounding edema, contrast-enhanced fast FLAIR imaging was superior to fast FLAIR or T2-weighted in 22 of 27 tumors with peritumoral edema (81%). Quantitatively, CNR was the highest on contrast-enhanced fast FLAIR image and the lowest on fast FLAIR. For the detection of leptomeningeal metastases, contrast-enhanced fast FLAIR was partially superior to contrast-enhanced T1-weighted imaging in two of three high-grade gliomas. Although contrast-enhanced fast FLAIR imaging should not be seen as a replacement for conventional modalities, it provides additional informaton for assessment of the extent of glial cell tumors and leptomeningeal metastases in patients with brain tumors. (author)

  15. A novel technique of contrast-enhanced optical coherence tomography imaging in evaluation of clearance of lipids in human tears.

    Science.gov (United States)

    Napoli, Pietro Emanuele; Coronella, Franco; Satta, Giovanni Maria; Fossarello, Maurizio

    2014-01-01

    The aim of this work was to gather preliminary data in different conditions of healthy eyes, aqueous tear deficient dry eyes, obstructive meibomian gland disease (MGD) and non-obvious obstructive MGD (NOMGD) individuals, using a new, contrast-enhanced optical coherence tomography (OCT) imaging method to evaluate the clearance of lipids in human tears. Eighty-two adult patients presenting with complaints of ocular irritation were studied for abnormalities of the ocular surface and classified as healthy (n = 21), aqueous tear deficient dry eyes (n = 20), obstructive MGD (n = 15) and NOMGD (n = 26) individuals. A lipid-based tracer, containing an oil-in-water emulsion, was used to obtain an enhanced OCT imaging of the lower tear meniscus. After instillation, a dramatic initial increase of reflectivity of the lower tear meniscus was detected by OCT, followed by a decay back to baseline values over time. Based on this finding, the clearance of lipids was measured in real-time by Fourier-domain anterior segment OCT. The differences in the clearance of lipids among the four groups as well as the correlations between symptom questionnaire score, standardized visual scale test, fluorescein break-up time, ocular surface fluorescein staining score, Schirmer I test scores were found to be statistically significant. The individual areas under the curve of the clearance of lipids calculated by the receiver operating characteristic curve technique ranged from 0.66 to 0.98, suggesting reliable sensitivity and specificity of lipid-enhanced OCT imaging. This new technique of contrast-enhanced OCT imaging of the tear film following lipid-based tracer instillation provides a measure of the clearance of lipids. The quantitative values found are in agreement with other methods of evaluation of the lacrimal system. An improvement of the clinician's ability in the diagnosis and understanding of abnormalities of the ocular surface may be achieved by this simple approach.

  16. A parallelizable real-time motion tracking algorithm with applications to ultrasonic strain imaging

    International Nuclear Information System (INIS)

    Jiang, J; Hall, T J

    2007-01-01

    Ultrasound-based mechanical strain imaging systems utilize signals from conventional diagnostic ultrasound systems to image tissue elasticity contrast that provides new diagnostically valuable information. Previous works (Hall et al 2003 Ultrasound Med. Biol. 29 427, Zhu and Hall 2002 Ultrason. Imaging 24 161) demonstrated that uniaxial deformation with minimal elevation motion is preferred for breast strain imaging and real-time strain image feedback to operators is important to accomplish this goal. The work reported here enhances the real-time speckle tracking algorithm with two significant modifications. One fundamental change is that the proposed algorithm is a column-based algorithm (a column is defined by a line of data parallel to the ultrasound beam direction, i.e. an A-line), as opposed to a row-based algorithm (a row is defined by a line of data perpendicular to the ultrasound beam direction). Then, displacement estimates from its adjacent columns provide good guidance for motion tracking in a significantly reduced search region to reduce computational cost. Consequently, the process of displacement estimation can be naturally split into at least two separated tasks, computed in parallel, propagating outward from the center of the region of interest (ROI). The proposed algorithm has been implemented and optimized in a Windows (registered) system as a stand-alone ANSI C++ program. Results of preliminary tests, using numerical and tissue-mimicking phantoms, and in vivo tissue data, suggest that high contrast strain images can be consistently obtained with frame rates (10 frames s -1 ) that exceed our previous methods

  17. Process algebra with timing : real time and discrete time

    NARCIS (Netherlands)

    Baeten, J.C.M.; Middelburg, C.A.; Bergstra, J.A.; Ponse, A.J.; Smolka, S.A.

    2001-01-01

    We present real time and discrete time versions of ACP with absolute timing and relative timing. The starting-point is a new real time version with absolute timing, called ACPsat, featuring urgent actions and a delay operator. The discrete time versions are conservative extensions of the discrete

  18. Process algebra with timing: Real time and discrete time

    NARCIS (Netherlands)

    Baeten, J.C.M.; Middelburg, C.A.

    1999-01-01

    We present real time and discrete time versions of ACP with absolute timing and relative timing. The startingpoint is a new real time version with absolute timing, called ACPsat , featuring urgent actions and a delay operator. The discrete time versions are conservative extensions of the discrete

  19. Contrast-enhanced magnetic resonance imaging of pulmonary lesions: Description of a technique aiming clinical practice

    International Nuclear Information System (INIS)

    Koenigkam-Santos, Marcel; Optazaite, Elzbieta; Sommer, Gregor; Safi, Seyer; Heussel, Claus Peter; Kauczor, Hans-Ulrich

    2015-01-01

    To propose a technique for evaluation of pulmonary lesions using contrast-enhanced MRI; to assess morphological patterns of enhancement and correlate quantitative analysis with histopathology. Material and methods: Thirty-six patients were prospectively studied. Volumetric-interpolated T1W images were obtained during consecutive breath holds after bolus triggered contrast injection. Volume coverage of first three acquisitions was limited (higher temporal resolution) and last acquisition obtained at 4th min. Two radiologists individually evaluated the patterns of enhancement. Region-of-interest-based signal intensity (SI)-time curves were created to assess quantitative parameters. Results: Readers agreed moderately to substantially concerning lesions’ enhancement pattern. SI-time curves could be created for all lesions. In comparison to benign, malignant lesions showed higher values of maximum enhancement, early peak, slope and 4th min enhancement. Early peak >15% showed 100% sensitivity to detect malignancy, maximum enhancement >40% showed 100% specificity. Conclusions: The proposed technique is robust, simple to perform and can be applied in clinical scenario. It allows visual evaluation of enhancement pattern/progression together with creation of SI-time curves and assessment of derived quantitative parameters. Perfusion analysis was highly sensitive to detect malignancy, in accordance to what is recommended by most recent guidelines on imaging evaluation of pulmonary lesions

  20. Contrast-enhanced magnetic resonance imaging of pulmonary lesions: Description of a technique aiming clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Koenigkam-Santos, Marcel, E-mail: marcelk46@yahoo.com.br [Department of Diagnostic and Interventional Radiology, University of Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Radiology Department, German Cancer Research Center (Deutsches Krebsforschungszentrum – DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Department of Radiology, University Hospital of the School of Medicine of Ribeirao Preto, University of Sao Paulo, Avenida Bandeirantes 3900, Campus Universitario Monte Alegre, 14048 900 Ribeirao Preto, Sao Paulo (Brazil); Optazaite, Elzbieta, E-mail: optazaite@andrulis.eu [Diagnostic and Interventional Radiology with Nuclear Medicine, Chest Clinic (Thoraxklinik), University of Heidelberg, Amalienstraße 5, 69126 Heidelberg (Germany); Sommer, Gregor, E-mail: gregor.sommer@usb.ch [Clinic of Radiology and Nuclear Medicine, University Hospital Basel, Petersgraben 4, CH-4031 Basel (Switzerland); Safi, Seyer, E-mail: seyer.safi@gmail.com [Surgery Department, Chest Clinic (Thoraxklinik), University of Heidelberg, Amalienstraße 5, 69126 Heidelberg (Germany); Heussel, Claus Peter, E-mail: heussel@uni-heidelberg.de [Diagnostic and Interventional Radiology with Nuclear Medicine, Chest Clinic (Thoraxklinik), University of Heidelberg, Amalienstraße 5, 69126 Heidelberg (Germany); Translational Lung Research Center (TLRC), Member of the German Center for Lung Research (DZL), Im Neuenheimer Feld 350, 69120 Heidelberg (Germany); Kauczor, Hans-Ulrich, E-mail: hans-ulrich.kauczor@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University of Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Translational Lung Research Center (TLRC), Member of the German Center for Lung Research (DZL), Im Neuenheimer Feld 350, 69120 Heidelberg (Germany); and others

    2015-01-15

    To propose a technique for evaluation of pulmonary lesions using contrast-enhanced MRI; to assess morphological patterns of enhancement and correlate quantitative analysis with histopathology. Material and methods: Thirty-six patients were prospectively studied. Volumetric-interpolated T1W images were obtained during consecutive breath holds after bolus triggered contrast injection. Volume coverage of first three acquisitions was limited (higher temporal resolution) and last acquisition obtained at 4th min. Two radiologists individually evaluated the patterns of enhancement. Region-of-interest-based signal intensity (SI)-time curves were created to assess quantitative parameters. Results: Readers agreed moderately to substantially concerning lesions’ enhancement pattern. SI-time curves could be created for all lesions. In comparison to benign, malignant lesions showed higher values of maximum enhancement, early peak, slope and 4th min enhancement. Early peak >15% showed 100% sensitivity to detect malignancy, maximum enhancement >40% showed 100% specificity. Conclusions: The proposed technique is robust, simple to perform and can be applied in clinical scenario. It allows visual evaluation of enhancement pattern/progression together with creation of SI-time curves and assessment of derived quantitative parameters. Perfusion analysis was highly sensitive to detect malignancy, in accordance to what is recommended by most recent guidelines on imaging evaluation of pulmonary lesions.