WorldWideScience

Sample records for reagent preparation on-line

  1. A dedicated on-line system for the preparation and validation of standard beads in XRF analysis

    International Nuclear Information System (INIS)

    Yamamoto, Yasuyuki; Ogasawara, Noriko; Nakata, Akio; Shoji, Shizuko.

    1995-01-01

    A dedicated on-line system in X-ray Fluorescence (XRF) analysis with glass-bead method was developed in which preparation of standard beads was automated including proper choice of reagents, assignment of bead compositions and validation of the prepared beads. This system features: a. Fundamental Parameter (FP) Method for validation of standard beads. b. An original database of high purity reagents for standards. c. Automatic calculation of suitable composition for each standard bead, by giving a range for each element and the number of standard beads. 1) The calculation is based on random numbers, and makes a random assignment of composition for each bead. 2) The calculation results are automatically stored in a computer as a condition file for quantitative analysis. 3) An amount of a material for a standard mixture is corrected if a valence or a chemical compound for an analysis element is different from that of the standard material in the database. In order to realize these features, many high purity reagents were examined for their purities and other characteristics to test a suitability to use for a standard material, and a software for on-line processings was originally developed. (author)

  2. Rapid reagent-less on-line H2O2 quantification in alkaline semiconductor etching solution, Part 2: Nephelometry application.

    Science.gov (United States)

    Zlatev, Roumen; Stoytcheva, Margarita; Valdez, Benjamin

    2018-03-01

    A simple and rapid reagent less nephelometric method for on-line H 2 O 2 quantification in semiconductors etching solutions was developed, optimized, characterized and validated. The intensity of the light scattered by the oxygen gas suspension resulted from H 2 O 2 catalytic decomposition by immobilized MnO 2 was registered as analytical response. The influences of the light wave length, the agitation rate, the temperature and the catalyst surface area on the response amplitude were studied and optimization was done. The achieved linear concentration range from 10 to 150mmolL -1 at 0.9835 calibration curve correlation coefficient, precision from 3.65% to 0.95% and response time from 35 to 20s respectively, at sensitivity of 8.01µAmmol -1 L and LOD of 2.9mmolL -1 completely satisfy the semiconductor industry requirements. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Technical Report (Final): Development of Solid State Reagents for Preparing Radiolabeled Imaging Agents

    Energy Technology Data Exchange (ETDEWEB)

    Kabalka, George W

    2011-05-20

    The goal of this research was on the development of new, rapid, and efficient synthetic methods for incorporating short-lived radionuclides into agents of use in measuring dynamic processes. The initial project period (Year 1) was focused on the preparation of stable, solid state precursors that could be used to efficiently incorporate short-lived radioisotopes into small molecules of use in biological applications (environmental, plant, and animal). The investigation included development and evaluation of new methods for preparing carbon-carbon and carbon-halogen bonds for use in constructing the substrates to be radiolabeled. The second phase (Year 2) was focused on developing isotope incorporation techniques using the stable, boronated polymeric precursors. The final phase (Year 3), was focused on the preparation of specific radiolabeled agents and evaluation of their biodistribution using micro-PET and micro-SPECT. In addition, we began the development of a new series of polymeric borane reagents based on polyethylene glycol backbones.

  4. Spectrophotometric determination of metformin in pharmaceutical preparations, serum and urine using benzoin as derivatizing reagent

    International Nuclear Information System (INIS)

    Alamgir, M.; Hayat, A.

    2014-01-01

    A simple and selective spectrophotometric procedure is described for the determination of Metformin based on derivatization with benzoin. The Beers law was obeyed with 2.50-12.50 meu mol L-1 at 290 nm with coefficient of determination (r2) 0.997. The experimental conditions in term of pH, reaction time and temperature, and addition of derivatizing reagent were examined. The pure metformin-benzoin derivative was prepared and characterized by FT-IR and mass spectroscopic techniques. The method was applied for the determination of metformin from pharmaceutical preparations and serum and urine of volunteers after spiking with metformin. The results were checked by standard addition method. A number of pharmaceutical additives and serum or urine matrix did not affect the determination of metformin. (author)

  5. On-line Automated Sample Preparation-Capillary Gas Chromatography for the Analysis of Plasma Samples.

    NARCIS (Netherlands)

    Louter, A.J.H.; van der Wagt, R.A.C.A.; Brinkman, U.A.T.

    1995-01-01

    An automated sample preparation module, (the automated sample preparation with extraction columns, ASPEC), was interfaced with a capillary gas chromatograph (GC) by means of an on-column interface. The system was optimised for the determination of the antidepressant trazodone in plasma. The clean-up

  6. Automation and integration of multiplexed on-line sample preparation with capillary electrophoresis for DNA sequencing

    Energy Technology Data Exchange (ETDEWEB)

    Tan, H.

    1999-03-31

    The purpose of this research is to develop a multiplexed sample processing system in conjunction with multiplexed capillary electrophoresis for high-throughput DNA sequencing. The concept from DNA template to called bases was first demonstrated with a manually operated single capillary system. Later, an automated microfluidic system with 8 channels based on the same principle was successfully constructed. The instrument automatically processes 8 templates through reaction, purification, denaturation, pre-concentration, injection, separation and detection in a parallel fashion. A multiplexed freeze/thaw switching principle and a distribution network were implemented to manage flow direction and sample transportation. Dye-labeled terminator cycle-sequencing reactions are performed in an 8-capillary array in a hot air thermal cycler. Subsequently, the sequencing ladders are directly loaded into a corresponding size-exclusion chromatographic column operated at {approximately} 60 C for purification. On-line denaturation and stacking injection for capillary electrophoresis is simultaneously accomplished at a cross assembly set at {approximately} 70 C. Not only the separation capillary array but also the reaction capillary array and purification columns can be regenerated after every run. DNA sequencing data from this system allow base calling up to 460 bases with accuracy of 98%.

  7. Preparation and optimization of ammonium phospho-molybdate reagent (FMA) (NH4)3[PMo12O40

    International Nuclear Information System (INIS)

    Cruz C, W.; Mallaupoma G, M.; Rodriguez C, G.

    1996-01-01

    The characteristics of low and medium level liquid radioactive waste produced in the Nuclear Research Center RACSO was identified, taking into account the philosophy of radiological safety. In liquid wastes, Cs-137 radionuclide could be present, which is important for radio-sanitary considerations. Its half life is 30 years. In the radioactive waste management, it is possible to separate Cs-137 by using a chemical treatment. One of the used chemical reagents is ammonium phospho-molybdate (FMA). The preparation method and the production optimization of FMA in the laboratory scale for its use as an economical reagent in the separation of Cs-137 radionuclide is shown in this paper. The objective is to get the higher decontamination factor and to reduce the volume containing the higher activity of the Cs-137 radionuclide. (authors). 4 refs., 2 tabs

  8. Small scale extraction and purification of human prolactin for the preparation of radioimmunoassay reagents

    International Nuclear Information System (INIS)

    Dias, L.E.M.F.

    1989-01-01

    Purification of human prolactin from pituitaries was carried out in our laboratory to obtain a pure reagent for use in RIA. The extraction and purification procedure was adapted from the method of Mc. Lean et al., and it involves the following steps: 1. Extraction of frozen pituitaries in buffers 0.14M phosphate/citrate pH 4.0 and 0.05M ammonium acetate pH 10.0. 2. Purification by hydrophobic interaction chromatography on Phenyl-Sepharose CL-4B in the presence of acetonitrile. 3. Purification by anion exchange chromatography on DEAE-Sepharose Cl-68. The purification method is considered effective for obtaining a hPrl of the purity needed for radioassay purposes, having the advantage of rapidity and relative simplicity. (author) [pt

  9. Fast method to determine the elements in maize flour: reduction in preparation time and reagent consumption

    Directory of Open Access Journals (Sweden)

    Irineo Kelte Filho

    2017-10-01

    Full Text Available Abstract The aim of this work was to develop and validate methodology to reduce the digestion time and reagent consumption in the determination of minerals in maize flour. The standard methodology employed in Brazil is that described by AOAC. It consists of the calcination of the sample at high temperatures for a long period of time, making the process expensive and slow. In this work, a wet sample digestion method using HNO3 was employed, heating on a block digester with final dissolution in an ultrasonic bath. The validation tests involved linearity and working range studies, and the determination of the detection and quantification limits, accuracy and precision. The sample digestion time was 1:30 h and the percent recoveries for the metals were 93% for Ca, 98% for Cu, 110% for Fe, 97% for Mg, 101% for Mn and 106% for Zn.

  10. Preparation of ore blocks for mine leaching by reagent explosion injection

    Science.gov (United States)

    Shevchenko, YuS

    2017-02-01

    The current drilling-and-blasting operations fail to prepare intact ore body underlying a production horizon for subsequent mining and leaching. It is found that the required preparation quality is possible by means of advanced implementation of ore body discontinuity and filling of the resultant system of joints with active leaching solutions.

  11. Preparation and evaluation of primary reagents for the radioimmunoassay of prolactin hormone as a diagnostic marker for some clinical applications

    International Nuclear Information System (INIS)

    Ebeid, N.H.A.

    2010-01-01

    The preparation of high technology radioimmunoassay (RIA) reagents with low cost is considered to be one of the main objectives of the present study. This may be extremely helpful in diagnosis and treatment of disorders of the anterior pituitary gland or the hypothalamus portion of the brain. The local prolactin (PRL) liquid-phase and solid-phase RIA systems were prepared for the invitro assessment of human prolactin in human serum i.e., (hyperprolactinemia, can occur as a result of pituitary adenomas and hypoprolactinemia are observed in cases of hypopituitarism).The objectives of the present work were designed to achieve: -The production of PRL polyclonal antibodies , PRL standards and radiolabeled PRL tracers. - Optimization of local radioimmunoassay methods (liquid phase - double antibody and solid phase - cellulose particles). - Validation studies of the local assay were carried out using the performance characteristics of the succeeded immunoassays. In the present study, liquid phase and solid phase RIA systems for measurement of PRL proved to be specific, sensitive, precise and accurate. This may suggest that, the liquid and solid phase RIA techniques should be suited for routine laboratory use and have been used effectively in the diagnosis and treatment of patient with pituitary dysfunctions and possible reproductive disability.

  12. An International Standard for specifying the minimum potency of anti-D blood-grouping reagents: evaluation of a candidate preparation in an international collaborative study

    NARCIS (Netherlands)

    Thorpe, S. J.; Fox, B.; Heath, A. B.; Scott, M.; de Haas, M.; Kochman, S.; Padilla, A.

    2006-01-01

    The aim of this study was to evaluate a lyophilized monoclonal immunoglobulin M (IgM) anti-D preparation for use as an International Standard to specify a recommended minimum acceptable potency of anti-D blood-grouping reagents. The candidate International Standard (99/836) for specifying the

  13. Hydrothermal Preparation and Characterization of Ultralong Strontium-Substituted Hydroxyapatite Whiskers Using Acetamide as Homogeneous Precipitation Reagent

    Science.gov (United States)

    Xu, Jianqiang; Yang, Yaoqi; Wan, Rong; Zhang, Weibin

    2014-01-01

    The ultralong strontium- (Sr-) substituted hydroxyapatite (SrHAp) whiskers were successfully prepared using acetamide as homogeneous precipitation reagent. The effect of the Sr substitution amount on the lattice constants and proliferation of human osteoblast cells (MG-63) was further investigated. The results showed that the SrHAp whiskers with diameter of 0.2–12 μm and ultralong length up to 200 μm were obtained and the Sr substitution level could be facilely tailored by regulating the initial molar ratio of Sr/(Sr + Ca) in raw materials. The Sr2+ replaced part of Ca2+ and the lattice constants increased apparently with the increase of the Sr substitution amount. Compared with the pure HAp whiskers, the Sr substitution apparently stimulated the proliferation of MG-63 at certain extracted concentrations. Our study suggested that the obtained SrHAp whiskers might be used as bioactive and mechanical reinforcement materials for hard tissue regeneration applications. PMID:24592192

  14. Preparation of the Reagent

    Indian Academy of Sciences (India)

    Srimath

    Analysis of carbohydrates is a significant part of qualitative organic analysis at the undergraduate level. A qualitative test that distingui- shes them from other classes of organic compounds is the Molisch test. Depending on their structure, sugars are classified ... Chemistry Department. Zakir Husain College. J.L.Nehru Marg.

  15. Reversed-phase liquid chromatography coupled on-line with capillary gas chromatography use of an anion-exchange membrane to remove an ion-pair reagent from the eluent.

    NARCIS (Netherlands)

    Brinkman, U.A.T.; Goosens, E.C.; de Jong, D.; de Jong, G.J.; Beerthuizen, I.M.

    1995-01-01

    In order to enable the coupling of reversed-phase liquid chromatography (RPLC) with capillary gas chromatography (GC), the performance of an anion-exchange micromembrane device has been studied to remove the ion-pair reagent methanesulphonic acid from an acetonitrile/water LC eluent. The regenerant

  16. On-line comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for preparative isolation of Peucedanum praeruptorum.

    Science.gov (United States)

    Wang, Xin-Yuan; Li, Jia-Fu; Jian, Ya-Mei; Wu, Zhen; Fang, Mei-Juan; Qiu, Ying-Kun

    2015-03-27

    A new on-line comprehensive preparative two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was developed for the separation of complicated natural products. It was based on the use of a silica gel packed medium-pressure column as the first dimension and an ODS preparative HPLC column as the second dimension. The two dimensions were connected with normal-phase (NP) and reversed-phase (RP) enrichment units, involving a newly developed airflow assisted adsorption (AAA) technique. The instrument operation and the performance of this NPLC × RPLC separation method were illustrated by gram-scale isolation of ethanol extract from the roots of Peucedanum praeruptorum. In total, 19 compounds with high purity were obtained via automated multi-step preparative separation in a short period of time using this system, and their structures were comprehensively characterized by ESI-MS, (1)H NMR, and (13)C NMR. Including two new compounds, five isomers in two groups with identical HPLC and TLC retention values were also obtained and identified by 1D NMR and 2D NMR. This is the first report of an NPLC × RPLC system successfully applied in an on-line preparative process. This system not only solved the interfacing problem of mobile-phase immiscibility caused by NP and RP separation, it also exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Optimization in the preparation of the YBa2Cu3O7-δ compound using BaCO3 and BaO2 reagents

    International Nuclear Information System (INIS)

    Bustamante D, A.; Flores S, J.

    2004-01-01

    The traditional superconductor YBa 2 Cu 3 O 7-δ (Y123) has an orthorhombic crystalline structure with spatial group Pmmm and its critical temperature is 90K. The literature reports the use of reagent BaCO 3 for the preparation by the solid state reaction which requires one calcination and two thermal treatments in oxygen flow at 950 o C. In this work we report the comparison in the preparation of Y123 using the BaO 2 reagent as another possibility for preparation; in this case we have used only two thermal treatments in oxygen flow at 950 o C; therefore reducing the costs in preparation. The powder XRD pattern of samples prepared with BaO 2 confirm a well crystallized phase an the diffraction lines of the main phase can be indexed with an orthorhombic unit cell. The ac susceptibility measurement in the range 5-100 K using a Quantum Design (SQUID) magnetometer for two samples confirms the superconductor behavior with critical temperature Tc ≅ 91 K. The critical temperatures for these systems were found taken account the derivatives of the susceptibility curves. Scanning Electron Microscopy (SEM) confirms the good behavior of the grains corresponding to both methods. (orig.)

  18. Diagnostic reagent system

    International Nuclear Information System (INIS)

    1976-01-01

    A solid phase reagent for use in radioimmunoassay of antigens and antibodies is described. The reagent is prepared by mixing specific antibody or radiolabeled antigen with polyethylene glycol (4000-6000) and gamma globulin in a buffer at pH 4-10 and lyophilizing, the antigens being thyroxine, triiodothyronine, digoxin and digitoxin (1-1000 μCi 125 I/μg). The buffer consists of a 0.08 molar sodium barbital solution containing 0.1% of ox-serum albumin and 0.35% of 8-anilino-1-naftalene sulfonic acid

  19. Preparation of submicron-sized spherical particles of gold using laser-induced melting in liquids and low-toxic stabilizing reagent

    International Nuclear Information System (INIS)

    Tsuji, T.; Higashi, Y.; Tsuji, M.; Ishikawa, Y.; Koshizaki, N.

    2015-01-01

    Highlights: • Submicron-sized spherical particles of gold were prepared using laser irradiation for the source gold nanoparticles stabilized by NaCl. • The source gold nanoparticles agglomeration was controlled both by the NaCl concentration of and by laser irradiation. • The formation process and the laser-fluence dependence of the particle size of gold nanoparticles in NaCl solutions differs from those in citrate solutions. • We revealed that properties of ligands are significantly important to prepare submicron-sized spherical particles and to control their size. - Abstract: Laser-induced melting in liquids (LIML) was applied to prepare spherical submicron-sized particles of gold (AuSMPs) from gold nanoparticles (AuNPs) stabilized using NaCl. Because undesirable byproducts, which might be generated when organic reagents such as citrate are used as the stabilizing reagent, are not generated from NaCl by laser irradiation, AuSMPs fabricated from AuNPs stabilized by NaCl will be low toxic. The AuSMPs were obtained by laser irradiation of the source AuNPs in NaCl solutions stabilized by NaCl at the proper concentration. Similar to the preparation of AuSMPs from AuNPs stabilized by citrate, the agglomeration of the source AuNPs, which is necessary to obtain AuSMPs, was controlled both by the NaCl concentration and by laser irradiation. However, the formation process and the laser-fluence dependence of the particle size of AuSMPs differed for various NaCl solutions and citrate solutions

  20. Sampling and sample preparation development for analytical and on-line measurement techniques of process liquids; Naeytteenoton ja kaesittelyn kehittaeminen prosessinesteiden analytiikan ja on-line mittaustekniikan tarpeisiin - MPKT 11

    Energy Technology Data Exchange (ETDEWEB)

    Karttunen, K [Oulu Univ. (Finland)

    1999-12-31

    Main goal of the research project is to develop sampling and sample handling methods and techniques for pulp and paper industry to be used for analysis and on-line purposes. The research focus specially on the research and development of the classification and separation methods and techniques needed for liquid and colloidal substances as well as in ion analysis. (orig.)

  1. Sampling and sample preparation development for analytical and on-line measurement techniques of process liquids; Naeytteenoton ja kaesittelyn kehittaeminen prosessinesteiden analytiikan ja on-line mittaustekniikan tarpeisiin - MPKT 11

    Energy Technology Data Exchange (ETDEWEB)

    Karttunen, K. [Oulu Univ. (Finland)

    1998-12-31

    Main goal of the research project is to develop sampling and sample handling methods and techniques for pulp and paper industry to be used for analysis and on-line purposes. The research focus specially on the research and development of the classification and separation methods and techniques needed for liquid and colloidal substances as well as in ion analysis. (orig.)

  2. Preparation of ZnO Nanoparticles and Photocatalytic H2 Production Activity from Different Sacrificial Reagent Solutions

    Science.gov (United States)

    Peng, Tian-you; Lv, Hong-jin; Zeng, Peng; Zhang, Xiao-hu

    2011-08-01

    ZnO nanoparticles were synthesized via a direct precipitation method followed by a heterogeneous azeotropic distillation and calcination processes, and then characterized by X-ray power diffraction, scanning electron microscopy, transmission electron microscopy, and nitrogen adsorption-desorption measurement. The effects of Pt-loading amount, calcination temperature, and sacrificial reagents on the photocatalytic H2 evolution efficiency from the present ZnO suspension were investigated. The experimental results indicate that ZnO nanoparticles calcined at 400 °C exhibit the best photoactivity for the H2 production in comparison with the samples calcined at 300 and 500 °C, and the photocatalytic H2 production efficiency from a methanol solution is much higher than that from a triethanolamine solution. It can be ascribed to the oxidization of methanol also contributes to the H2 production during the photochemical reaction process. Moreover, the photocatalytic mechanism for the H2 production from the present ZnO suspension system containing methanol solution is also discussed in detail.

  3. Standardization of human thyrotropin radioimmunoassay and its application to the purification of this hormone to the preparation of the assay reagents

    International Nuclear Information System (INIS)

    Lin, L.H.

    1991-01-01

    The various steps that are necessary for setting up the thyrotropin radioimmunoassay are presented below. Radioiodination was carried out through the Chloramine T method and the labeled purification performed on Sephadex G-100. Purification of human thyrotropin from side fractions obtained during the purification of growth hormone was carried out in order to obtain a pure reagent for use in the radioimmunoassay. The employment of the hormone obtained was evaluated as the radioimmunoassay tracer in comparison with that prepared from the hormone received from the NIDDKD, U.S.A. The results indicated that although it was not possible to obtain a hormone with a purity degree adequate to be used as the tracer, enough experience was acquired for the isolation of thyrotropin. (author)

  4. Simulated Target Preparation and Separation of Cd (II) - In (III) Matrices Using 8-Hydroxyquinoline Reagent for Producing Indium - III Radioisotope

    International Nuclear Information System (INIS)

    Sunarhadijoso Soenarjo; Swasono R Tamat; Lukiyawati; Lintang Maharani

    2002-01-01

    The potency of production and application of 111 In in Indonesia is not supported yet by capability in required processing technology. The presented paper is a preliminary study on processing technology of 111 In production from 112 Cd target covering simulated target preparation and separation of Cd(II)-In(III) matrices. The target preparation was performed by means of electroplating of CdSO 4 solution prepared from reaction of CdO and sulphuric acid. The separation of Cd(II)-In(III) matrices was proceeded by means of solvent extraction in the presence of 8-hydroxyquinoline as In(III)-complexing agent. The Cd-electroplating deposit was satisfactorily found by using 40-60 mA currents with an electroplating time of 5-7 hours. Simulated matrix solution containing mixture of Cd(II) and In(III) was extracted into chloroform with the presence of 8-hydroxyquinoline. The chloroform phase being assumed to contain In(III)-8-hydroxyquinoline complex was then re-extracted with 1 M HCl or saline solution. Each extraction fraction was spectrophotometrically identified in the region of 200-400 nm. From the resulting absorption spectra, it can be shown that the In(III) species is selectively separated from the Cd(II)-matrix. The use of saline in the re-extraction process is better then 1 M HCl solution due to solubility of 8-hydroxyquinoline in HCl. (author)

  5. Evaluation of slurry preparation procedures for the determination of mercury by axial view inductively coupled plasma optical emission spectrometry using on-line cold vapor generation

    International Nuclear Information System (INIS)

    Santos, Eder Jose dos; Herrmann, Amanda Beatriz; Antunes Vieira, Mariana; Azzolin Frescura, Vera Lucia; Curtius, Adilson Jose

    2005-01-01

    Five different slurry preparation procedures were tested, after grinding the solid samples to a particle size ≤53 μm: (1) using aqua regia plus HF, 30 min of sonication, standing time of 24 h followed by another 30 min of sonication; (2) same as the previous one, except that the standing time and the second ultrasound treatment were omitted; (3) same as the previous one, except that HF was not used; (4) same as the previous one, except that the aqua regia was replaced by nitric acid; (5) same as the previous one, except that the acid nitric was replaced by tetramethylammonium hydroxide (TMAH). The Hg vapor was generated on-line, and the emission signal intensity measured at 253.652 nm by axial view inductively coupled plasma optical emission spectrometry. Initially, four experimental conditions were optimized using a multivariate factorial analysis: the concentrations of HCl and of the reducing agent, NaBH 4 , used in the cold vapor generation, and two instrumental parameters, the plasma radiofrequency power and the carrier gas flow rate. The radiofrequency power was statistically significant, but limited to 1.2 kW for practical reasons. The procedures were applied to 11 biological and environmental materials. Both, the slurries and the filtrates were analyzed, using calibration solutions in the same medium as in the slurries. The first three procedures produced results in agreement with the certified values. The two last procedures, using nitric acid or TMHA could not be used for quantitative analysis. For practical reasons, Procedure 3, with a detection limit (3s, n=10) of 0.06 μg g -1 for a sample mass of 20 mg in a final volume of 15 mL is recommended. The relative standard deviations for mercury in the investigated materials, using the recommended procedure, were lower than 12.5%, indicating a good precision for slurry sampling. The recommended procedure is simple, rapid and robust

  6. Two-Dimensional Capillary Electrophoresis with On-Line Sample Preparation and Cyclodextrin Separation Environment for Direct Determination of Serotonin in Human Urine.

    Science.gov (United States)

    Piešťanský, Juraj; Maráková, Katarína; Mikuš, Peter

    2017-10-07

    An advanced two-dimensional capillary electrophoresis method, based on on-line combination of capillary isotachophoresis and capillary zone electrophoresis with cyclodextrin additive in background electrolyte, was developed for effective determination of serotonin in human urine. Hydrodynamically closed separation system and large bore capillaries (300-800 µm) were chosen for the possibility to enhance the sample load capacity, and, by that, to decrease limit of detection. Isotachophoresis served for the sample preseparation, defined elimination of sample matrix constituents (sample clean up), and preconcentration of the analyte. Cyclodextrin separation environment enhanced separation selectivity of capillary zone electrophoresis. In this way, serotonin could be successfully separated from the rest of the sample matrix constituents migrating in capillary zone electrophoresis step so that human urine could be directly (i.e., without any external sample preparation) injected into the analyzer. The proposed method was successfully validated, showing favorable parameters of sensitivity (limit of detection for serotonin was 2.32 ng·mL -1 ), linearity (regression coefficient higher than 0.99), precision (repeatability of the migration time and peak area were in the range of 0.02-1.17% and 5.25-7.88%, respectively), and recovery (ranging in the interval of 90.0-93.6%). The developed method was applied for the assay of the human urine samples obtained from healthy volunteers. The determined concentrations of serotonin in such samples were in the range of 12.4-491.2 ng·mL -1 that was in good agreement with literature data. This advanced method represents a highly effective, reliable, and low-cost alternative for the routine determination of serotonin as a biomarker in human urine.

  7. Characterization of Reagent Pencils for Deposition of Reagents onto Paper-Based Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Cheyenne H. Liu

    2017-08-01

    Full Text Available Reagent pencils allow for solvent-free deposition of reagents onto paper-based microfluidic devices. The pencils are portable, easy to use, extend the shelf-life of reagents, and offer a platform for customizing diagnostic devices at the point of care. In this work, reagent pencils were characterized by measuring the wear resistance of pencil cores made from polyethylene glycols (PEGs with different molecular weights and incorporating various concentrations of three different reagents using a standard pin abrasion test, as well as by measuring the efficiency of reagent delivery from the pencils to the test zones of paper-based microfluidic devices using absorption spectroscopy and digital image colorimetry. The molecular weight of the PEG, concentration of the reagent, and the molecular weight of the reagent were all found to have an inverse correlation with the wear of the pencil cores, but the amount of reagent delivered to the test zone of a device correlated most strongly with the concentration of the reagent in the pencil core. Up to 49% of the total reagent deposited on a device with a pencil was released into the test zone, compared to 58% for reagents deposited from a solution. The results suggest that reagent pencils can be prepared for a variety of reagents using PEGs with molecular weights in the range of 2000 to 6000 g/mol.

  8. Polymeric reagents

    International Nuclear Information System (INIS)

    Bozkurt, C.

    1979-01-01

    The system polymer-bound triphenyl phosphine/carbon tetrachloride was used for preparation of 14 C-labelled organic compounds. 7- 14 C-benzyl chloride, 7- 14 C-benzoyl chloride and 7- 14 C-N-butyl benzamide have been prepared in this way. The reaction conditions were optimized using inactive compounds. Using the results of this optimization, radiochemical yields of 90% could be obtained for the first time for the preparation of 14 C-labelled alkyl chlorides and carboxylic acid chlorides from the corresponding alcohols and acids on the carrier. Polymer-bound triphenylphosphine was further studied as a catalyst for Beckmann rearrangement on the example of the rearrangement of cyclohexanoneoxime into epsilon-caprolactam. Yields exceeding 90% could be obtained with polymer-bound triphenylphosphine. However, regeneration of the catalyst could only be achieved by the already known method using trichlorosilane, in part also with methyldichlorosilane. Other reducing agents were unsuccessful in regenerating the catalyst. (G.G.)

  9. Preparing women for breast screening mammography: A feasibility study to determine the potential value of an on-line social network and information hub

    International Nuclear Information System (INIS)

    Robinson, L.; Griffiths, M.; Wray, J.; Ure, C.; Shires, G.; Stein-Hodgins, J.R.; Hill, C.; Hilton, B.

    2015-01-01

    This feasibility study explored the attitudes of women towards social media for support about breast screening mammography. It sought their ideas about what a dedicated breast screening hub or Digital Support Network (DSN) might comprise; how they would network with other women on the DSN; what format information might take; and whether a health professional should be available on the DSN. Data comprised 94 survey questionnaires and two focus groups; one comprised women in the breast screening population age group, the other was a younger group. A socio-ecological framework was used to identify key influencers and potential barriers for the implementation of a mammography DSN. The study identified issues related to three intersecting concepts which influenced women's behaviour: on-line conversations about health in general; on-line conversations about breast screening mammography and the culture of privacy which makes conversing about intimate health (either face to face or on-line) difficult. Also, the transient nature of the mammography episode (three yearly), could mean an on-line breast screening digital network is challenging to sustain. super-users’ may be needed to continue on-line conversations. The health professional was also seen as essential for moderating potential misinformation shared by women although the participants were also insistent that ‘truth’ be shared. - Highlights: • Ensure factual information is provided that is in textual format with images and video. • Provide option to network in private. • Develop health practitioners who can provide a balanced perspective in facilitating the sharing of true experiences. • Work with employers to implement organisational changes. • Target certain groups in more direct ways (i.e. those with lower self-efficacy in terms of on-line skills).

  10. Determination of thromboxanes, leukotrienes and lipoxins using high-temperature capillary liquid chromatography-tandem mass spectrometry and on-line sample preparation

    DEFF Research Database (Denmark)

    Dahl, Sandra Rinne; Kleiveland, Charlotte Ramstad; Kassem, Moustapha

    2009-01-01

    An on-line strong cation-exchange (SCX)-reversed-phase (RP) capillary liquid chromatographic (cLC) method with ion-trap tandem mass spectrometric (IT-MS/MS) detection for the simultaneous determination of thromboxane (TX) B(2), TXB(3), leukotriene (LT) B(4), LTD(4) and lipoxin (LX) A(4) in cell...

  11. Handling Pyrophoric Reagents

    Energy Technology Data Exchange (ETDEWEB)

    Alnajjar, Mikhail S.; Haynie, Todd O.

    2009-08-14

    Pyrophoric reagents are extremely hazardous. Special handling techniques are required to prevent contact with air and the resulting fire. This document provides several methods for working with pyrophoric reagents outside of an inert atmosphere.

  12. New on-line separation workflow of microbial metabolites via hyphenation of analytical and preparative comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Yan, Xia; Wang, Li-Juan; Wu, Zhen; Wu, Yun-Long; Liu, Xiu-Xiu; Chang, Fang-Rong; Fang, Mei-Juan; Qiu, Ying-Kun

    2016-10-15

    Microbial metabolites represent an important source of bioactive natural products, but always exhibit diverse of chemical structures or complicated chemical composition with low active ingredients content. Traditional separation methods rely mainly on off-line combination of open-column chromatography and preparative high performance liquid chromatography (HPLC). However, the multi-step and prolonged separation procedure might lead to exposure to oxygen and structural transformation of metabolites. In the present work, a new two-dimensional separation workflow for fast isolation and analysis of microbial metabolites from Chaetomium globosum SNSHI-5, a cytotoxic fungus derived from extreme environment. The advantage of this analytical comprehensive two-dimensional liquid chromatography (2D-LC) lies on its ability to analyze the composition of the metabolites, and to optimize the separation conditions for the preparative 2D-LC. Furthermore, gram scale preparative 2D-LC separation of the crude fungus extract could be performed on a medium-pressure liquid chromatograph×preparative high-performance liquid chromatography system, under the optimized condition. Interestingly, 12 cytochalasan derivatives, including two new compounds named cytoglobosin Ab (3) and isochaetoglobosin Db (8), were successfully obtained with high purity in a short period of time. The structures of the isolated metabolites were comprehensively characterized by HR ESI-MS and NMR. To be highlighted, this is the first report on the combination of analytical and preparative 2D-LC for the separation of microbial metabolites. The new workflow exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Application and recovery of ionic liquids in the preparative separation of four flavonoids from Rhodiola rosea by on-line three-dimensional liquid chromatography.

    Science.gov (United States)

    Ma, Shufeng; Hu, Liming; Ma, Chaoyang; Lv, Wenping; Wang, Hongxin

    2014-09-01

    A novel on-line three-dimensional liquid chromatography method was developed to separate four main flavonoids from Rhodiola rosea. Ethyl acetate/0.5 mol/L ionic liquid 1-butyl-3-methylimidazolium chloride aqueous solution was selected as the solvent system. In the first-dimension separation, the target flavonoids were entrapped and subsequently desorbed into the second-dimension high-speed countercurrent chromatographic column for separation. In the third-dimension chromatography, the residual ionic liquid in the four separated flavonoids was removed and the used ionic liquid was recovered. As a result, 35.1 mg of compound 1, 20.4 mg of compound 2, 8.5 mg of compound 3, and 10.6 mg of compound 4 were obtained from 1.53 g R. rosea extract. They were identified as rhodiosin, rhodionin, herbacetin, and kaempferol, respectively. The recovery of ionic liquid reached 99.1% of the initial amount. The results showed that this method is a powerful technology for the separation of R. rosea flavonoids and that the ionic-liquid-based solvent system has advantages over traditional solvent systems in renewable and environmentally friendly properties. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. On-line filtering

    International Nuclear Information System (INIS)

    Verkerk, C.

    1978-01-01

    Present day electronic detectors used in high energy physics make it possible to obtain high event rates and it is likely that future experiments will face even higher data rates than at present. The complexity of the apparatus increases very rapidly with time and also the criteria for selecting desired events become more and more complex. So complex in fact that the fast trigger system cannot be designed to fully cope with it. The interesting events become thus contaminated with multitudes of uninteresting ones. To distinguish the 'good' events from the often overwhelming background of other events one has to resort to computing techniques. Normally this selection is made in the first part of the analysis of the events, analysis normally performed on a powerful scientific computer. This implies however that many uninteresting or background events have to be recorded during the experiment for subsequent analysis. A number of undesired consequences result; and these constitute a sufficient reason for trying to perform the selection at an earlier stage, in fact ideally before the events are recorded on magnetic tape. This early selection is called 'on-line filtering' and it is the topic of the present lectures. (Auth.)

  15. Review Article: Toxic Effects of Some Reagents Used in Electron ...

    African Journals Online (AJOL)

    Ultrathin sections prepared for electron microscopy and histochemistry are indispensable in cytological, histological and histochemical studies. The paper discusses the various reagents used in these fields of study. Unfortunately, these reagents and chemicals are hazardous to health. There is wisdom in informing the ...

  16. 21 CFR 864.4020 - Analyte specific reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Analyte specific reagents. 864.4020 Section 864.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Specimen Preparation Reagents § 864.4020 Analyte specific...

  17. 21 CFR 864.4010 - General purpose reagent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false General purpose reagent. 864.4010 Section 864.4010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Specimen Preparation Reagents § 864.4010 General purpose...

  18. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1997-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging, describe some of the image registration methods that have been developed to determine geometric errors quantitatively, and discuss how portal imaging has been incorporated into clinical practice. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices include T.V. camera-based systems, liquid ionisation chamber systems, and shortly, flat panel systems. The characteristics of these imaging systems will be discussed. In addition, other approaches such as the use of kilovoltage x-ray sources, video monitoring, and ultrasound have been proposed for improving patient positioning. Some of the advantages of these approaches will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. One problem is finding a common frame of reference for the simulator and portal images, since the location of the radiation field within the pixel matrix may differ for the two images. As a result, a common frame of reference has to be established before the anatomic structures in the images can be registered - generally by registering radiation field edges identified in the simulator and portal images. In addition, distortions in patient geometry or rotations out of the image plane can confound the image registration techniques. Despite the

  19. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1996-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine geometric errors quantitatively; discuss some of the ways that portal imaging has been incorporated into routine clinical practice; describe quality assurance procedures for these devices, and discuss the use of portal imaging devices for dosimetry applications. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. However, the task is not nearly as straight-forward as it sounds. One problem

  20. Resolution and isolation of enantiomers of (±)-isoxsuprine using thin silica gel layers impregnated with L-glutamic acid, comparison of separation of its diastereomers prepared with chiral derivatizing reagents having L-amino acids as chiral auxiliaries.

    Science.gov (United States)

    Bhushan, Ravi; Nagar, Hariom

    2015-03-01

    Thin silica gel layers impregnated with optically pure l-glutamic acid were used for direct resolution of enantiomers of (±)-isoxsuprine in their native form. Three chiral derivatizing reagents, based on DFDNB moiety, were synthesized having l-alanine, l-valine and S-benzyl-l-cysteine as chiral auxiliaries. These were used to prepare diastereomers under microwave irradiation and conventional heating. The diastereomers were separated by reversed-phase high-performance liquid chromatography on a C18 column with detection at 340 nm using gradient elution with mobile phase containing aqueous trifluoroacetic acid and acetonitrile in different compositions and by thin-layer chromatography (TLC) on reversed phase (RP) C18 plates. Diastereomers prepared with enantiomerically pure (+)-isoxsuprine were used as standards for the determination of the elution order of diastereomers of (±)-isoxsuprine. The elution order in the experimental study of RP-TLC and RP-HPLC supported the developed optimized structures of diastereomers based on density functional theory. The limit of detection was 0.1-0.09 µg/mL in TLC while it was in the range of 22-23 pg/mL in HPLC and 11-13 ng/mL in RP-TLC for each enantiomer. The conditions of derivatization and chromatographic separation were optimized. The method was validated for accuracy, precision, limit of detection and limit of quantification. Copyright © 2014 John Wiley & Sons, Ltd.

  1. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1995-01-01

    Purpose/Objective: The purpose of this presentation is to review the physics of imaging with high energy x-ray beams; examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine errors in patient positioning quantitatively; and discuss some of the ways that portal imaging has been incorporated into routine clinical practice. Verification of patient positioning has always been an important aspect of external beam radiation therapy. Checks of patient positioning have generally been done with film, however, film suffers from a number of drawbacks, such as poor image display and delays due to film development. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems, which are intended to overcome the limitations of portal films. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The fundamental factors which limit image quality and the characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same

  2. PEGylated N-methyl-S-methyl dithiocarbazate as a new reagent for the high-yield preparation of nitrido Tc-99m and Re-188 radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Boschi, Alessandra, E-mail: alessandra.boschi@unife.i [Laboratory of Nuclear Medicine, Department of Radiological Sciences, University of Ferrara, 44100 Ferrara (Italy); Massi, Alessandro [Department of Chemistry, University of Ferrara, 44100 Ferrara (Italy); Uccelli, Licia; Pasquali, Micol; Duatti, Adriano [Laboratory of Nuclear Medicine, Department of Radiological Sciences, University of Ferrara, 44100 Ferrara (Italy)

    2010-11-15

    A novel nitrido nitrogen atom donor for the preparation of {sup 99m}Tc and {sup 188}Re radiopharmaceuticals containing a metal-nitrogen multiple bond is presented. HO{sub 2}C-PEG{sub 600}-DTCZ was obtained by conjugation of N-methyl-S-methyl dithiocarbazate [H{sub 2}N-N(CH{sub 3})-C({identical_to}S)SCH{sub 3}, HDTCZ] with polyethylene glycol 600 (PEG{sub 600}). Asymmetrical heterocomplexes of the type [M(N)(PNP)(B)]{sup 0/+} (M={sup 99m}Tc, {sup 188}Re; PNP=diphosphine ligands, B=DBODC, DEDC, NSH, H{sub 2}OS, CysNAc, HDTCZ) and symmetrical nitride compounds of the type [M(N)(L){sub 2}] (L=DEDC, DPDC) have been prepared in high yield by using the newly designed nitride nitrogen atom donor HO{sub 2}C-PEG{sub 600}-DTCZ. A two-step procedure was applied for preparing the above symmetrical and asymmetrical complexes. The first step involved the preliminary formation of a mixture of nitride Tc-99m or Re-188 precursors, which contained the [M{identical_to}N]{sup 2+} core, through reduction of generator-eluted {sup 99m}Tc-pertechnetate or {sup 188}Re-perrhenate with thin (II) chloride in the presence of HO{sub 2}C-PEG{sub 600}-DTCZ. In the second step, the intermediate mixture was converted either in the final mixed asymmetrical complex by the simultaneous addition of diphosphine ligand and the suitable bidentate ligand B, or in the final symmetrical complex by the only addition of the bidentate ligand L. It was also demonstrated that the novel water-soluble nitride nitrogen atom donor HO{sub 2}C-PEG{sub 600}-DTCZ did not show coordinating properties toward the M{identical_to}N ({sup 99m}Tc, {sup 188}Re) core. Biodistribution studies in rats of the hitherto unreported [{sup 99m}Tc(N)(PNP{sub 3})DTCZ]{sup +} and [{sup 99m}Tc(N)(PNP{sub 5})DTCZ]{sup +} complexes showed that they selectively localize in the myocardium of rats with a favourable heart-to-lung and heart-to-liver uptake ratios. In particular, the heart-to-lung and heart-to-liver uptake ratios dramatically

  3. Table sugar as preparation and carbon coating reagent for facile synthesis and coating of rod-shaped MnO{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Hashem, Ahmed M., E-mail: ahmedh242@yahoo.co [National Research Centre, Inorganic Chemistry Department, Behoes St., Dokki, Cairo (Egypt); Abuzeid, Hanaa M. [National Research Centre, Inorganic Chemistry Department, Behoes St., Dokki, Cairo (Egypt); Nikolowski, Kristian; Ehrenberg, Helmut [Institute for Complex Materials, IFW Dresden, Helmholtzstr. 20, D-01069 Dresden (Germany)

    2010-05-14

    Rod-shaped {alpha}-MnO{sub 2} has been synthesized by a novel and facile wet chemical method using simple sugar and potassium permanganate. Redox reaction between KMnO{sub 4} and sucrose is carried out in an acidic medium. Acidic medium provides a reducing character to sucrose through its decomposition to elemental carbon. Carbon coating process was done using simple sugar also as a source for carbon in an absolute ethanol with heating the mixture of {alpha}-MnO{sub 2} and sugar at 350 {sup o}C for an hour in an ambient atmosphere. A single phase of cryptomelane-like phase MnO{sub 2} was observed from XRD patterns for bare and carbon coated samples. TGA analysis shows the presence of carbon layer through more weight loss percent of carbon coated sample in comparison with that of carbon free MnO{sub 2}. Both virgin and carbon coated MnO{sub 2} have high thermal stability due to high percent of K inside the tunnel determined from ICP analysis. Transmission Electron Microscope (TEM) showed a rod-shaped crystal for both the parent and carbon coated {alpha}-MnO{sub 2} and confirmed the presence of a thin film of carbon around MnO{sub 2} particles. Both XRD and TEM investigations show that the prepared powders are in nano-scale. Initial capacity of about 140 mAh/g was obtained for the parent and carbon coated samples. The results show also that carbon coating process improves the capacity retention and the efficiency of {alpha}-MnO{sub 2} in comparison with that carbon free sample.

  4. Spectrophotometric determination of tannins by phosphotungstic-phosphomolybdic reagent

    Energy Technology Data Exchange (ETDEWEB)

    Reicher, F; Sierakowski, M R; Correa, J B.C. [Parana Univ., Curitiba (Brazil). Dept. de Bioquimica

    1981-01-01

    There are several colorimetric techniques to determine tannins in plant extracts. One frequently used is the Folin method (phosphotungstic acid reagent) that procedures a blue color with phenolic compounds. However, this coloured complex is unstable. With the Folin-Ciocalteau reagent, used in protein determination (Lowry et al. J.B.C. 193: 265, 1951) good results were obtained, even in the absence of cooper solution. Using phosphotungstic-phosphomolybdic reagent (Folin-Denis), it was obtained maximum color with 1,0 ml of the reagent in 20 minutes, after the additon of 10 ml 20% sodium carbonate solution. Tannins samples containing 10 to 200 ..mu..g/ml were analysed. Absorbances are determined at 720 or 600 nm. Tannins of commercial preparations from Acacia negra were analysed by the phosphotungstic-phosphomolybdic reagent before (A) and after (B) treatment with chromate hyde powder. By this procedure hydrolysible tannins were determined (A-B).

  5. Spectrophotometric determination of tannins by phosphotungstic-phosphomolibdic reagent

    International Nuclear Information System (INIS)

    Reicher, F.; Sierakowski, M.R.; Correa, J.B.C.

    1981-01-01

    There are several colorimetric techniques to determine tannins in plant extracts. One frequently used is the Folin method (phosphotungstic acid reagent) that procedures a blue color with phenolic compounds. However, this coloured complex is unstable. With the Folin-Ciocalteau reagent, used in protein determination (Lowry et al. J.B.C. 193: 265, 1951) good results were obtained, even in the absence of cooper solution. Using phosphotungstic-phosphomolibdic reagent (Folin-Denis), it was obtained maximum color with 1,0 ml of the reagent in 20 minutes, after the adition of 10 ml 20% sodium carbonate solution. Tannins samples containing 10 to 200 μg/ml were analysed. Absorbances are determined at 720 or 600 nm. Tannins of commercial preparations from Acacia negra were analysed by the phosphotungstic-phosphomolibdic reagent before (A) and after (B) treatment with chromate hyde powder. By this procedure hydrolysible tannins were determined (A-B). (Author) [pt

  6. Alkylation of pyridines at their 4-positions with styrenes plus yttrium reagent or benzyl Grignard reagents.

    Science.gov (United States)

    Mizumori, Tomoya; Hata, Takeshi; Urabe, Hirokazu

    2015-01-02

    A new regioselective alkylation of pyridines at their 4-position was achieved with styrenes in the presence of yttrium trichloride, BuLi, and diisobutylaluminium hydride (DIBAL-H) in THF. Alternatively, similar products were more simply prepared from pyridines and benzyl Grignard reagents. These reactions are not only a useful preparation of 4-substituted pyridines but are also complementary to other relevant reactions usually giving 2-substituted pyridines. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. N-tritioacetoxyphthalimide: A new high specific activity tritioacetylating reagent

    International Nuclear Information System (INIS)

    Saljoughian, M.; Morimoto, Hiromi; Than, Chit

    1996-01-01

    The authors' aim was to develop a nonvolatile, stable, and facile tritioacetylating reagent and to demonstrate its use on simple peptides. Accordingly, the authors made the synthesis of high specific activity N-(tritioacetoxy) derivatives of succinimide, phthalimide, and naphthalimide a major focus. As the preferred approach, N-(tritioacetoxy)phthalimide was prepared by radical dehalogenation of N-(iodoacetoxy)phthalimide using high specific activity tributyltin tritide. This tritiated acetylation reagent was characterized by 3 H and 1 H NMR spectroscopy and by radio-HPLC. Efficacy of the reagent was investigated by tritioacetylation of several peptides at their N-terminal amino group. 26 refs., 1 fig

  8. [An evaluation of the China-made HIV antibody test reagents].

    Science.gov (United States)

    Zheng, X W; Zhu, D

    1990-06-01

    This paper reports the results of the evaluation of the China-made HIV antibody screening test reagents, including the IF and IE reagents prepared by the Institute of Virology, CAPM, the ELISA reagent prepared by the Shanghai Institute of Biological Products. Based on the results, the sensitivities of the IF and IE are from 91.2% to 96.9%; the specificities, from 94.6% to 97.3%. Due to the low HIV prevalence in China, the predictive values of negative of these reagents are up to 100%; but the predictive values of positive are very low. It is suggested that these reagents can be used for HIV antibody screen testing in China. The package of some reagents should be improved, the price of some reagents should be decreased.

  9. Fast biosensor with reagent layer

    NARCIS (Netherlands)

    2008-01-01

    A detection system and a sensor chip for detecting target mols., and thus corresponding analytes in a sample is described. Typically the detection system includes a sensor chip. The sensor chip (1) comprises on its detection surface a dissolvable reagent layer. When the dissolvable reagent layer is

  10. CERN Video News on line

    CERN Multimedia

    2003-01-01

    The latest CERN video news is on line. In this issue : an interview with the Director General and reports on the new home for the DELPHI barrel and the CERN firemen's spectacular training programme. There's also a vintage video news clip from 1954. See: www.cern.ch/video or Bulletin web page

  11. On-line moisture analysis

    CERN Document Server

    Cutmore, N G

    2002-01-01

    Measurement of the moisture content of iron ore has become a key issue for controlling moisture additions for dust suppression. In most cases moisture content is still determined by manual or automatic sampling of the ore stream, followed by conventional laboratory analysis by oven drying. Although this procedure enables the moisture content to be routinely monitored, it is too slow for control purposes. This has generated renewed interest in on-line techniques for the accurate and rapid measurement of moisture in iron ore on conveyors. Microwave transmission techniques have emerged over the past 40 years as the dominant technology for on-line measurement of moisture in bulk materials, including iron ores. Alternative technologies have their limitations. Infra-red analysers are used in a variety of process industries, but rely on the measurement of absorption by moisture in a very thin surface layer. Consequently such probes may be compromised by particle size effects and biased presentation of the bulk mater...

  12. On line ultrasonic integrated backscatter

    International Nuclear Information System (INIS)

    Landini, L.; Picano, E.; Mazzarisi, A.; Santarelli, F.; Benassi, A.; De Pieri, G.

    1988-01-01

    A new equipment for on-line evaluation of index based on two-dimensional integrated backscatter from ultrasonic images is described. The new equipment is fully integrated into a B-mode ultrasonic apparatus which provides a simultaneous display of conventional information together with parameters of tissue characterization. The system has been tested with a backscattering model of microbubbles in polysaccharide solution, characterized by a physiological exponential time decay. An exponential fitting to the experimental data was performed which yielded r=0.95

  13. On-line nuclear orientation

    International Nuclear Information System (INIS)

    Krane, K.S.

    1990-01-01

    This grant has as its overall goal the pursuit of on-line nuclear orientation experiments for the purpose of eliciting details of nuclear structure from the decays of neutron-deficient nuclei, such as those produced by the Holifield Heavy-Ion Research Facility at Oak Ridge and extracted by the UNISOR Isotope Separator. This paper discusses: refrigerator development; the decay of 184 Au; the decay of 191 Hg to 191 Au; the decay of 189 Pt to 189 Ir; the decays of 109,111 Pd; the decay of 172 Er; and solid angle corrections

  14. A Catalyst-Free Amination of Functional Organolithium Reagents by Flow Chemistry.

    Science.gov (United States)

    Kim, Heejin; Yonekura, Yuya; Yoshida, Jun-Ichi

    2018-04-03

    Reported is the electrophilic amination of functional organolithium intermediates with well-designed aminating reagents under mild reaction conditions using flow microreactors. The aminating reagents were optimized to achieve efficient C-N bond formation without using any catalyst. The electrophilic amination reactions of functionalized aryllithiums were successfully conducted under mild reaction conditions, within 1 minute, by using flow microreactors. The aminating reagent was also prepared by the flow method. Based on stopped-flow NMR analysis, the reaction time for the preparation of the aminating reagent was quickly optimized without the necessity of work-up. Integrated one-flow synthesis consisting of the generation of an aryllithium, the preparation of an aminating reagent, and their combined reaction was successfully achieved to give the desired amine within 5 minutes of total reaction time. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Software for on-line experiments

    International Nuclear Information System (INIS)

    Ivanchenko, I.M.

    1981-01-01

    A review of nowadays development state of software of on-line electron experiments is presented. The principles of organization of real time systems on second generation computer base are considered. The following methods for projections search are considered: combinator methods, global methods, methods of tracking, methods of a supporting band. The following methods for determining parameter estimates based on the Lorentz equation are analysed: analytical simulation of trajectories, determination of parameters by the iterative method using the technique of calculation of recycled integrals, multidimensional statistical analysis. For the purpose of successful usage and development of software the technique of selfdocumented programs is created and the computer is applied for preparing, revising and circulation of external descriptions which as program complexes are constructed according to the hierarchical principle [ru

  16. On-line moisture analysis

    International Nuclear Information System (INIS)

    Cutmore, N.G.; Mijak, D.G

    2002-01-01

    Measurement of the moisture content of iron ore has become a key issue for controlling moisture additions for dust suppression. In most cases moisture content is still determined by manual or automatic sampling of the ore stream, followed by conventional laboratory analysis by oven drying. Although this procedure enables the moisture content to be routinely monitored, it is too slow for control purposes. This has generated renewed interest in on-line techniques for the accurate and rapid measurement of moisture in iron ore on conveyors. Microwave transmission techniques have emerged over the past 40 years as the dominant technology for on-line measurement of moisture in bulk materials, including iron ores. Alternative technologies have their limitations. Infra-red analysers are used in a variety of process industries, but rely on the measurement of absorption by moisture in a very thin surface layer. Consequently such probes may be compromised by particle size effects and biased presentation of the bulk material. Nuclear-based analysers measure the total hydrogen content in the sample and do not differentiate between free and combined moisture. Such analysers may also be sensitive to material presentation and elemental composition. Very low frequency electromagnetic probes, such as capacitance or conductance probes, operate in the frequency region where the DC conductivity dominates much of the response, which is a function not only of moisture content but also of ionic composition and chemistry. These problems are overcome using microwave transmission techniques, which also have the following advantages, as a true bulk moisture analysis is obtained, because a high percentage of the bulk material is analysed; the moisture estimate is mostly insensitive to any biased presentation of moisture, for example due to stratification of bulk material with different moisture content and because no physical contact is made between the sensor and the bulk material. This is

  17. Decontaminating reagents for radioactive systems

    International Nuclear Information System (INIS)

    Seddon, W.A.

    1982-01-01

    A decontaminating reagent composition has been developed comprising EDTA, citric acid, oxalic acid, and formic acid. Formic acid inhibits the decomposition of both EDTA and citric acid, and yields oxalic acid as a result of its own radiolysis. The invention includes the improvement of initially incorporating formic acid in the mixture and maintaining the presence of formic acid by at least one further addition

  18. On extraction reagents for hydrometallurgy

    International Nuclear Information System (INIS)

    Zolotov, Yu.A.

    1975-01-01

    Fundamental requirements to the extractants are considered. Ways of obtaining selective extractants are discussed in particular on the basis of coordination chemistry achivements. Attention is drawn to expediency of study (as extractants) of flotation reagents, additions to the oil, pesticides, accelerators of caoutchouc vulcanization

  19. Application of flotational reagents obtained from coke-industry byproducts

    Energy Technology Data Exchange (ETDEWEB)

    N.I. Nikitin; I.N. Nikitin; N.I. Toporkova [Khar' kov Polytechnic Institute (Ukraine)

    2007-06-15

    Today, the operational efficiency of coal-preparation shops at coke plants largely depends on the flotation process, since flotation is the basic method of regenerating the slurry water in the water-slurry systems and the basic enrichment process for small-grain coal slurries. At The Coal-Chemistry Institute, attempts have been made to address the growing demand for readily available and relatively inexpensive flotational reagents. In particular, a list of promising coke-industry byproducts for use as flotational reagents has been compiled, and the possibility of reducing their toxicity has been established. In addition, various industrial byproducts and wastes have been investigated in terms of flotational activity.

  20. On-line data display

    Science.gov (United States)

    Lang, Sherman Y. T.; Brooks, Martin; Gauthier, Marc; Wein, Marceli

    1993-05-01

    A data display system for embedded realtime systems has been developed for use as an operator's user interface and debugging tool. The motivation for development of the On-Line Data Display (ODD) have come from several sources. In particular the design reflects the needs of researchers developing an experimental mobile robot within our laboratory. A proliferation of specialized user interfaces revealed a need for a flexible communications and graphical data display system. At the same time the system had to be readily extensible for arbitrary graphical display formats which would be required for data visualization needs of the researchers. The system defines a communication protocol transmitting 'datagrams' between tasks executing on the realtime system and virtual devices displaying the data in a meaningful way on a graphical workstation. The communication protocol multiplexes logical channels on a single data stream. The current implementation consists of a server for the Harmony realtime operating system and an application written for the Macintosh computer. Flexibility requirements resulted in a highly modular server design, and a layered modular object- oriented design for the Macintosh part of the system. Users assign data types to specific channels at run time. Then devices are instantiated by the user and connected to channels to receive datagrams. The current suite of device types do not provide enough functionality for most users' specialized needs. Instead the system design allows the creation of new device types with modest programming effort. The protocol, design and use of the system are discussed.

  1. Determination of tin(II) in reagents for radiopharmaceuticals

    International Nuclear Information System (INIS)

    Morosanova, E.I.; Loginova, K. A.; Epstein, N.B.

    2003-01-01

    The goal of this work is to elaborate a procedure for rapid and simple determination of tin(II) in reagents for preparation of radiopharmaceuticals based on a system albumin-Tc-99m. Original test tools for the determination of various analytes have been suggested in our lab based on the use of small glass tubes (1-2 mm i.d. - 50-70 mm) filled with indicator powders containing suitable immobilized chromogenic reagents. An analytical signal (a length of colored zone which is proportional to the concentration of an analyte) is detected after a sample passing through the indicator tube. Heteropoly compounds are well-known analytical reagents for a photometric determination of various reductants. For elaboration of indicator tubes abilities of Mo,P-heteropoly compounds to give deeply colored blue compounds after reduction were used. (authors)

  2. Simplified automatic on-line document searching

    International Nuclear Information System (INIS)

    Ebinuma, Yukio

    1983-01-01

    The author proposed searching method for users who need not-comprehensive retrieval. That is to provide flexible number of related documents for the users automatically. A group of technical terms are used as search terms to express an inquiry. Logical sums of the terms in the ascending order of frequency of the usage are prepared sequentially and automatically, and then the search formulas, qsub(m) and qsub(m-1) which meet certain threshold values are selected automatically also. Users justify precision of the search output up to 20 items retrieved by the formula qsub(m). If a user wishes more than 30% of recall ratio, the serach result should be output by qsub(m), and if he wishes less than 30% of it, it should be output by qsub(m-1). The search by this method using one year volume of INIS Database (76,600 items) and five inquiries resulted in 32% of recall ratio and 36% of precision ratio on the average in the case of qsub(m). The connecting time of a terminal was within 15 minutes per an inquiry. It showed more efficiency than that of an inexperienced searcher. The method can be applied to on-line searching system for database in which natural language only or natural language and controlled vocabulary are used. (author)

  3. On-line maintenance PSA support at NPP Krsko

    International Nuclear Information System (INIS)

    Prosen, R.; Vrbanic, I.; Kastelan, M.

    2000-01-01

    In 1997 Krsko NPP initiated the on-line maintenance (OLM) practice. On-line maintenance constitutes of corrective activities, preventive activities, surveillance activities, tests and inspections, as well as calibrations and modifications, taking place during the normal power operations. The on-line maintenance is a multidisciplinary process consisting of activity specification, planning, and preparation and performing of the OLM activity of interest. The primary role of the PSA group is to assess from the r isk perspective , using the plant-specific NEK PSA model, system unavailability and the impact to the plant operational risk. The intent is to support planning of the on-line maintenance activities from the risk perspective. The risk evaluation of the OLM activities is based on the probability of core damage evaluation for the defined discrete plant configuration states, determined by the OLM activities. Within this application, the optimized, plant-specific PSA model is used on Risk Spectrum platform. To perform the risk assessment of the on-line maintenance activities, first the systems to be affected are defined based on the planned OLM activities. The next important step is the assessment of the planned work schedule. To define the final schedule, the co-ordination and optimizing the planned OLM activities needs activation of all participating departments, supported also from PSA group. The P3 (i.e. Primavera) planning tool system windows are defined for different systems and groups of systems, and the activities are sorted in particular weeks according to these windows. (author)

  4. Mentoring Narratives ON-LINE:Teaching the Principalship

    Directory of Open Access Journals (Sweden)

    Allison I. Griffith

    2002-05-01

    Full Text Available The need to develop new models for preparation of school administrators has been a prominent concern in educational discourse in the last decade. Having been criticized for the inadequate preparation of the school leadership cadre, academic departments responsible for training future school administrators have had to revisit their approaches and to reframe their teaching philosophies to ensure the readiness of their graduates for the challenges and complexities of school leadership. This article reports on the new model of principals' training that has been used in York University's Principals' Qualification Program (PQP from the late 1990s onward. One component of the program brings traditional case methodology into a computer-mediated/on-line environment. The on-line cases are narratives from the everyday lives of the Ontario school administrators who serve as mentors in the on-line environment. Situating our discussion within the context of the rapidly changing educational landscape of Ontario, we focus on the PQP model to explore experientially generated case narratives as one method for teaching and learning the work of the local school administrator. We focus particularly on the teaching and learning embedded in computer-mediated or on-line case narratives used in training teachers for school leadership. We argue that the complexities of school leadership—the social, cultural, relational, ethical and moral context of school leadership—can be taught effectively through the reflective processes of on-line case narratives. We seek to contribute to the ongoing dialogue on the potential of new pedagogies and new technologies to help prepare the competent and responsible leaders for tomorrow's schools.

  5. A reagent for processing drilling muds

    Energy Technology Data Exchange (ETDEWEB)

    Polyakov, G.A.; Khon-Pak, A.T.; Khon, A.V.; Normatov, L.N.; Telegin, B.V.

    1983-01-01

    A reagent is proposed for processing drilling muds. It contains an acrylic polymer and potassium permanganate. The reagent is distinguished by the fact that in order to improve the quality of the drilling muds by increasing their salt resistance, the reagent contains hydrolized nitron fiber as the acrylic polymer with the following component relationship (in percent by weight): potassium permanganate, 0.015 to 0.065 and hydrolyzed nitron fiber, the remainder.

  6. Storage Conditions of Conjugated Reagents Can Impact Results of Immunogenicity Assays

    Directory of Open Access Journals (Sweden)

    Robert J. Kubiak

    2016-01-01

    Full Text Available Consistent performance of anti-drug antibody (ADA assays through all stages of clinical development is critical for the assessment of immunogenicity and interpretation of PK, PD, safety, and efficacy. The electrochemiluminescent assays commonly employed for ADA measurement use drug conjugated with ruthenium and biotin to bind ADA in samples. Here we report an association between high nonspecific ADA responses in certain drug-naïve individuals and the storage buffer of the conjugated reagents used in a monoclonal antibody ADA assay. Ruthenylated reagents stored in phosphate-buffered saline (PBS buffer had increased levels of aggregate and produced variable and high baseline responses in some subjects. Reagents stored in a histidine-sucrose buffer (HSB had lower aggregate levels and produced low sample responses. In contrast to PBS, conjugated reagents formulated in HSB remained low in aggregate content and in sample response variability after 5 freeze/thaw cycles. A reagent monitoring control (RMC serum was prepared for the real-time evaluation of conjugated reagent quality. Using appropriate buffers for storage of conjugated reagents together with RMCs capable of monitoring of reagent aggregation status can help ensure consistent, long-term performance of ADA methods.

  7. Colorimetric Determination of the Iron(III)-Thiocyanate Reaction Equilibrium Constant with Calibration and Equilibrium Solutions Prepared in a Cuvette by Sequential Additions of One Reagent to the Other

    Science.gov (United States)

    Nyasulu, Frazier; Barlag, Rebecca

    2011-01-01

    The well-known colorimetric determination of the equilibrium constant of the iron(III-thiocyanate complex is simplified by preparing solutions in a cuvette. For the calibration plot, 0.10 mL increments of 0.00100 M KSCN are added to 4.00 mL of 0.200 M Fe(NO[subscript 3])[subscript 3], and for the equilibrium solutions, 0.50 mL increments of…

  8. Reagents for radioimmunological determination of carcinoembryonic antigen (CEA)

    International Nuclear Information System (INIS)

    Albert, Z.; Balbierz, H.; Breberowicz, J.

    1978-01-01

    The work was undertaken to prepare the reagents for carcinoembryonic antigen (CEA) radioimmunoassay with double antibody method. The CEA standard of high immunoreactivity was prepared and purified. The purified CEA was used for immunozation of goats. The goat anti - CEA sera were received. IgG fraction from normal goat serum was purified and used for the production of horse anti-goat IgG serum which was then used in the radioimmunoassay of CEA. The labelling of CEA with iodine-125 has been carried out be means of the enzymatic method.(Z.R.)

  9. Stability of Loop-Mediated Isothermal Amplification (LAMP) Reagents and its Amplification Efficiency on Crude Trypanosome DNA Templates

    OpenAIRE

    Thekisoe, Oriel M. M; Bazie, Raoul S. B; Coronel-Servian, Andrea M; Sugimoto, Chihiro; Kawazu, Shin-ichiro; Inoue, Noboru

    2009-01-01

    This study evaluated the stability of LAMP reagents when stored at 25C and 37C, and also assessed its detection efficiency on different DNA template preparations. Accordingly, LAMP using reagents stored at 25C and 37C amplified DNA of in vitro cultured T. b. brucei (GUTat 3.1) from day 1 to day 15 of reagent storage. There were no significant differences (P>0.05) in detection sensitivity of LAMP among the reagents stored at 25C, 37C and –20C (recommended storage temperature). LAMP usin...

  10. Modeling of On-Line Catalyst Addition Effects in a Short Contact Time Reactor

    National Research Council Canada - National Science Library

    Zerkle, David K; Allendorf, Mark Donald; Wolf, Markus; Deutschmann, Olaf

    2000-01-01

    ... operating ( on-line catalyst addition). Our simulations indicate that the fundamental behavior of the ethane SCTR prepared with catalyst added online is the result of coupled heterogeneous and homogeneous chemical processes...

  11. Inventory management and reagent supply for automated chemistry.

    Science.gov (United States)

    Kuzniar, E

    1999-08-01

    Developments in automated chemistry have kept pace with developments in HTS such that hundreds of thousands of new compounds can be rapidly synthesized in the belief that the greater the number and diversity of compounds that can be screened, the more successful HTS will be. The increasing use of automation for Multiple Parallel Synthesis (MPS) and the move to automated combinatorial library production is placing an overwhelming burden on the management of reagents. Although automation has improved the efficiency of the processes involved in compound synthesis, the bottleneck has shifted to ordering, collating and preparing reagents for automated chemistry resulting in loss of time, materials and momentum. Major efficiencies have already been made in the area of compound management for high throughput screening. Most of these efficiencies have been achieved with sophisticated library management systems using advanced engineering and data handling for the storage, tracking and retrieval of millions of compounds. The Automation Partnership has already provided many of the top pharmaceutical companies with modular automated storage, preparation and retrieval systems to manage compound libraries for high throughput screening. This article describes how these systems may be implemented to solve the specific problems of inventory management and reagent supply for automated chemistry.

  12. Shawnee Mission's On-Line Cataloging System

    Directory of Open Access Journals (Sweden)

    Ellen Wasby Miller

    1971-03-01

    Full Text Available An on-line cataloging pilot project for two elementary schools is discussed. The system components are 2740 terminals, upper-lower-case input, IBM's FASTER generalized software package, and usual cards/labels output. Reasons for choosing FASTER, software and hardware features, operating procedures, system performance and costs are detailed. Future expansion to cataloging 100,000 annual K-12 acquisitions, on-line circulation, retrospective conversion, and union book catalogs is set forth.

  13. INIS retrieval service, towards on-line

    International Nuclear Information System (INIS)

    Ebinuma, Yukio; Komatsubara, Yasutoshi

    1983-01-01

    Japan Atomic Energy Research Institute executes the retrieval service of INIS atomic energy information by batch system in cooperation with Genshiryoku Kozaikai. This service is very popular to the users in whole Japan, but the demand of on-line service has increased recently. Therefore, it was decided to begin the INIS on-line service from January, 1984, through the on-line information retrieval system of the Japan Information Center of Science and Technology. It is expected that when the operation will be started, the utilization of INIS atomic energy information in Japan will drastically increase. Also Japan Atomic Energy Research Institute has carried out the retrieval service by on-line system for those in the institute besides the batch system, accordingly, at this opportunity, the state of utilization of both systems and their distinction to use effectively, and the operation and the method of utilization of the on-line information retrieval system of JICST are explained. In the on-line system, the users are accessible to the data base themselves, and immediate information retrieval is possible, while in the batch system, the related information can be retrieved without fail, and the troublesome operation of equipment is not necessary. (Kako, I.)

  14. On-line radiation teaching materials using IT technology

    International Nuclear Information System (INIS)

    Inoue, Hiroyoshi

    2005-01-01

    We developed the on-line radiation teaching materials using the Internet, in order to provide the teaching support materials of atomic power and radiation educations in on-school study, as well as to create the complementary study system in off-school study. The themes of teaching materials were selected from requests by teachers. In the case of an elementary school, the teaching material 'an environmental problem and atomic power' was created as the aggregate of each content for study without boundary between subjects. The teaching material 'medical treatment and radiation' was created for junior high school students to raise the individual knowledge. In the case of a high school, the teaching material nucleus and radiation' was prepared to supplement the physical study of students. The on-line teaching materials were tried to 300 junior high school and high school students, 68% of students answered that the teaching material is effective to understand atomic power and radiation, though 17% answered they were not effective. Although there are problems to prepare IT learning equipments and learning follow-up system in the material, it is suggested that the on-line teaching materials will provide the novel learning system including debates for the study. This method has no limitation of time and place. (author)

  15. Inactivation of rabies diagnostic reagents by gamma radiation

    International Nuclear Information System (INIS)

    Gamble, W.C.; Chappell, W.A.; George, E.H.

    1980-01-01

    Treatment of CVS-11 rabies adsorbing suspensions and street rabies infected mouse brains with gamma radiation resulted in inactivated reagents that are safer to distribute and use. These irradiated reagents were as sensitive and reactive as the nonirradiated control reagents

  16. On-line monitoring for calibration reduction

    International Nuclear Information System (INIS)

    Hoffmann, M.

    2005-09-01

    On-Line Monitoring evaluates instrument channel performance by assessing its consistency with other plant indications. Elimination or reduction of unnecessary field calibrations can reduce associated labour costs, reduce personnel radiation exposure, and reduce the potential for calibration errors. On-line calibration monitoring is an important technique to implement a state-based maintenance approach and reduce unnecessary field calibrations. In this report we will look at how the concept is currently applied in the industry and what the arising needs are as it becomes more commonplace. We will also look at the PEANO System, a tool developed by the Halden Project to perform signal validation and on-line calibration monitoring. Some issues will be identified that are being addressed in the further development of these tools to better serve the future needs of the industry in this area. An outline for how to improve these points and which aspects should be taken into account is described in detail. (Author)

  17. Capillary electrophoresis microchip coupled with on-line chemiluminescence detection

    International Nuclear Information System (INIS)

    Su Rongguo; Lin Jinming; Qu Feng; Chen Zhifeng; Gao Yunhua; Yamada, Masaaki

    2004-01-01

    In the present work, chemiluminescence detection was integrated with capillary electrophoresis microchip. The microchip was designed on the principle of flow-injection chemiluminescence system and capillary electrophoresis. It has three main channels, five reservoirs and a detection cell. As model samples, dopamine and catechol were separated and detected using a permanganate chemiluminescent system on the prepared microchip. The samples were electrokinetically injected into the double-T cross section, separated in the separation channel, and then oxidized by chemiluminescent reagent delivered by a home-made micropump to produce light in the detection cell. The electroosmotic flow could be smoothly coupled with the micropump flow. The detection limits for dopamine and catechol were 20.0 and 10.0 μM, respectively. Successful separation and detection of dopamine and catechol demonstrated the distinct advantages of integration of chemiluminescent detection on a microchip for rapid and sensitive analysis

  18. On-line signal trend identification

    International Nuclear Information System (INIS)

    Tambouratzis, T.; Antonopoulos-Domis, M.

    2004-01-01

    An artificial neural network, based on the self-organizing map, is proposed for on-line signal trend identification. Trends are categorized at each incoming signal as steady-state, increasing and decreasing, while they are further classified according to characteristics such signal shape and rate of change. Tests with model-generated signals illustrate the ability of the self-organizing map to accurately and reliably perform on-line trend identification in terms of both detection and classification. The proposed methodology has been found robust to the presence of white noise

  19. On line routing per mobile phone

    DEFF Research Database (Denmark)

    Bieding, Thomas; Görtz, Simon; Klose, Andreas

    2009-01-01

    On-line routing is concerned with building vehicle routes in an ongoing fashion in such a way that customer requests arriving dynamically in time are efficiently and effectively served. An indispensable prerequisite for applying on-line routing methods is mobile communication technology....... Additionally it is of utmost importance that the employed communication system is suitable integrated with the firm’s enterprise application system and business processes. On basis of a case study, we describe in this paper a system that is cheap and easy to implement due to the use of simple mobile phones...

  20. On-line atomic data access

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, D.R. [Oak Ridge National Lab., TN (United States); Nash, J.K. [Lawrence Livermore National Lab., CA (United States)

    1996-04-01

    The need for atomic data is one which continues to expand in a wide variety of applications including fusion energy, astrophysics, laser- produced plasma research, and plasma processing. Modern computer database and communications technology nables this data to be placed on-line and obtained by users of the Internet. Presented here is a summary of the observations and conclusions regarding such on-line atomic data access derived from a forum held at the Tenth APS Topical Conference on Atomic Processes in Plasmas.

  1. 21 CFR 866.3780 - Toxoplasma gondii serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3780 Toxoplasma... (immunofluorescent reagents) used to identify Toxoplasma gondii from clinical specimens. The identification aids in...

  2. 21 CFR 866.3375 - Mycoplasma spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3375 Mycoplasma... fluorescent dye (immunofluorescent reagents) used to identify Mycoplasma spp. directly from clinical specimens...

  3. 21 CFR 866.3220 - Entamoeba histolytica serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3220... fluorescent dye (immunofluorescent reagents) used to identify Entamoeba histolytica directly from clinical...

  4. Rapid heteroatom transfer to arylmetals utilizing multifunctional reagent scaffolds

    Science.gov (United States)

    Gao, Hongyin; Zhou, Zhe; Kwon, Doo-Hyun; Coombs, James; Jones, Steven; Behnke, Nicole Erin; Ess, Daniel H.; Kürti, László

    2017-07-01

    Arylmetals are highly valuable carbon nucleophiles that are readily and inexpensively prepared from aryl halides or arenes and widely used on both laboratory and industrial scales to react directly with a wide range of electrophiles. Although C-C bond formation has been a staple of organic synthesis, the direct transfer of primary amino (-NH2) and hydroxyl (-OH) groups to arylmetals in a scalable and environmentally friendly fashion remains a formidable synthetic challenge because of the absence of suitable heteroatom-transfer reagents. Here, we demonstrate the use of bench-stable N-H and N-alkyl oxaziridines derived from readily available terpenoid scaffolds as efficient multifunctional reagents for the direct primary amination and hydroxylation of structurally diverse aryl- and heteroarylmetals. This practical and scalable method provides one-step synthetic access to primary anilines and phenols at low temperature and avoids the use of transition-metal catalysts, ligands and additives, nitrogen-protecting groups, excess reagents and harsh workup conditions.

  5. An on-line dilution system for spectrometry using an inductively coupled plasma source

    International Nuclear Information System (INIS)

    Moore, G.L.; Watson, A.E.; Humphries-Cuff, P.J.

    1982-01-01

    An on-line dilution system that uses a two-channel peristaltic pump to feed a GMK Babington type of nebulizer is described. By the use of a diluent containing the appropriate concentrations of acid, sodium, and internal standard element, which was fed at a constant rate to the nebulizer, the system produced analytical results that are not significantly different (less than 3 per cent relative) from those obtained with the normal dilution technique. However, a considerable saving in time is achieved, as well as a saving in the use of expensive reagents

  6. General-purpose chemical analyzer for on-line analyses of radioactive solutions

    International Nuclear Information System (INIS)

    Spencer, W.A.; Kronberg, J.W.

    1983-01-01

    An automated analyzer is being developed to perform analytical measurements on radioactive solutions on-line in a hostile environment. This General Purpose Chemical Analyzer (GPCA) samples a process stream, adds reagents, measures solution absorbances or electrode potentials, and automatically calculates the results. The use of modular components, under microprocessor control, permits a single analyzer design to carry out many types of analyses. This paper discusses the more important design criteria for the GPCA, and describes the equipment being tested in a prototype unit

  7. Development of national immunoassay reagent programmes

    International Nuclear Information System (INIS)

    Sufi, S.B.; Micallef, J.V.; Ahsan, R.; Goncharov, N.P.

    1992-01-01

    Despite the existence of networks of fully equipped laboratories with well-trained staff, the availability of immunodiagnostic services in developing countries is often limited by the high cost of imported kits. There are a number of ways of tackling this problem, ranging from bulk purchase of kits or reagents to local development and production of assay systems. Argentina/Chile, China, Cuba/Mexico, and Thailand are amongst the countries which have established local immunoassay reagent programmes to manufacture low cost, high quality immunoassay reagents. Kits from these projects are now beginning to become available, and it is hoped that they will promote national diagnostic services and research, as well as stimulating the development of reagent programmes for other analytes. (author). 4 refs, 1 tab

  8. On-line monitoring for calibration reduction

    International Nuclear Information System (INIS)

    Hoffmann, Mario; Gran, Frauke Schmitt; Thunem, Harald P-J.

    2004-04-01

    On-Line Monitoring (OLM) of a channel's calibration state evaluates instrument channel performance by assessing its consistency with other plant indications. Industry and experience at several plants has shown this overall approach to be very effective in identifying instrument channels that are exhibiting degrading or inconsistent performance characteristics. The Halden Reactor Project has developed the signal validation system PEANO, which can be used to assist with the tasks of OLM. To further enhance the PEANO System for use as a calibration reduction tool, the following two additional modules have been developed; HRP Prox, which performs pre-processing and statistical analysis of signal data, Batch Monitoring Module (BMM), which is an off-line batch monitoring and reporting suite. The purpose and functionality of the HRP Prox and BMM modules are discussed in this report, as well as the improvements made to the PEANO Server to support these new modules. The Halden Reactor Project has established a Halden On-Line Monitoring User Group (HOLMUG), devoted to the discussion and implementation of on-line monitoring techniques in power plants. It is formed by utilities, vendors, regulatory bodies and research institutes that meet regularly to discuss implementation aspects of on-line monitoring, technical specification changes, cost-benefit analysis and regulatory issues. (Author)

  9. SPIRES I: on-line search guide

    International Nuclear Information System (INIS)

    Addis, L.

    1975-06-01

    SPIRES I is the first generation of the on-line Stanford Public Information Retrieval System. Designed as a prototype system, SPIRES I was later moved to the SLAC computing facility where it has been routinely available to SLAC users in the field of high-energy physics. The scope and use of the SPIRES I system are described in this manual

  10. HOPI: on-line injection optimization program

    International Nuclear Information System (INIS)

    LeMaire, J.L.

    1977-01-01

    A method of matching the beam from the 200 MeV linac to the AGS without the necessity of making emittance measurements is presented. An on-line computer program written on the PDP10 computer performs the matching by modifying independently the horizontal and vertical emittance. Experimental results show success with this method, which can be applied to any matching section

  11. Development of reagents for radioimmunoassay of: triiodothyronine, thyroxine and thyrotrophin

    International Nuclear Information System (INIS)

    Delgado S, B.; Lavalley E, C.; Ruiz J, A.; Garcia F, C.; Zamorano A, F.

    1991-12-01

    The radioimmunoassay (RIA) of thyroid hormones it is the but it frequents of all the studies carried out by RIA in the laboratories of Nuclear Medicine, these essays are carried out with imported reagents. In the ININ the reagents and the necessary methodology have been developed for the triiodothyronine (T3), thyroxine (T4) and thyrotrophin (TSH). The good titles of the antibodies (Ac) primary for each hormone were of 1:4,000; 1:750 and 1:1,500. The used separation system was of double Ac with PEG to 10%, with titles of 1:10 for the second Ac of lamb. The specific activity for 125-I-T3 and 125-I-T4 oscillate between 850 at 900 μCi / μ g: being this of 90 μ Ci /μg for TSH. To the first two hormones they were added 1-8 aniline naftalen sulfonic acid (ANS) to concentrations of 3 and 2 mg/ml respectively. As buffer for T3 and T4 it was used Tris-HCl pH 8.6 and PBS with normal serum of rabbit (SNC) for TSH. The standards got ready in buffer or free serum of thyroid hormones. The slope of the standard curves varied between -2.3 to -2.7 and the variation intra and inter assay among 4 to 10%. It is had at the moment in the ININ with standardized reagents for the RIA of T3, T4 and TSH, it is hoped to carry out tests in other laboratories and to establish the conditions of stability more appropriate to begin the preparation of pilot reagents. (Author)

  12. Educational On-Line Gaming Propensity

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana; Kirchner, Kathrin

    2014-01-01

    Educational on-line games are promising for new generations of students who are grown up digital. Th e new generations of students are technology savvy and spend lots of time on the web and on social networks. Based on an exploratory study, this article investigates the factors that infl uence...... students’ willingness to participate in serious games for teaching/learning. Th is study investigates the relationship between students’ behavior on Facebook, Facebook games, and their attitude toward educational on-line games. Th e results of the study reveal that the early adopters of educational games...... are likely to be students, who are young, have only a few Facebook connections, who currently play Facebook game(s). Furthermore, the study emphasizes that there may be differences between students coming from various countries....

  13. Trends in on-line data processing

    International Nuclear Information System (INIS)

    Masetti, M.

    1981-01-01

    The developement of integrated circuits has been characterized by an exponential growth of gates on a single chip that will still continue in the coming years. In parallel the price per bit is dropping down with more or less the same law. As a consequence of this a few statements can be made: The present 16-bit minicomputer in a small configuration is going to be substituted by a 16-bit microcomputer, and the 16-bit microcomputer in a powerful configuration by a 32-bit midi having also a virtual memory facility. Fully programmable or microcoded powerful devices like the LASS hardware processor or MICE, will allow an efficient on-line filter. Higher computing speed can be achieved by a multiprocessor configuration which can be insensitive to hardware failures. Therefore we are moving towards an integrated on-line computing system with much higher computing power than now and the present distinction between on-line and off-line will no longer be so sharp. As more processing can be performed on-line, fast high quality feed-back can be provided for the experiment. In the years to come the trend towards more processing power, at a lower price, and assembled in the same hardware volume will continue for at least five years; at the same time the future large high-energy physics experiments at LEP will be carried out within a wide international collaboration. In this environment methods must be found for a large fraction of the work to be distributed amongst the collaborators. To accomplish this aim it is necessary to introduce common standard practices concerning both hardware and software, in such a way that the seperate parts, developed by the collaborators, will be plug-compatible. (orig.)

  14. New Trends in on-line Marketing

    OpenAIRE

    Palkovič, Lukáš

    2011-01-01

    This bachelor thesis deals with new trend of internet marketing, it focuses especially on viral marketing. The theoretical part charasterizes the process of viral campaigns, furthermore deals with the components and aspects of on-line environment. Another separated chapter presents social networks, their place in viral marketing and at last but not least the viral video making process. The practical part contains different analyses of specific viral campaigns. The next and equally the last pa...

  15. On-Line Maintenance Methodology Development

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo Won; Kim, Jae Ho; Jae, Moo Sung [Hanyang University, Seoul (Korea, Republic of)

    2012-05-15

    Most of domestic maintenance activities for nuclear power plants are performed while overhaul. Therefore, On-Line Maintenance (OLM) is one of the proper risks informed application techniques for diffusing maintenance burden during overhaul with safety of the plant is secured. The NUMARC 93-01 (Rev.3) presents the OLM state of the art and it provides methodology. This study adopts NUMARC 93-01 (Rev.3) and present OLM. The reference component is Emergency Diesel Generator (EDG) of Ulchin 3, 4

  16. 21 CFR 866.3200 - Echinococcus spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Echinococcus spp. serological reagents. 866.3200... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3200 Echinococcus spp. serological reagents. (a) Identification. Echinococcus spp. serological reagents are devices that...

  17. 21 CFR 866.3405 - Poliovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Poliovirus serological reagents. 866.3405 Section... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3405 Poliovirus serological reagents. (a) Identification. Poliovirus serological reagents are devices that consist of antigens...

  18. 21 CFR 866.3415 - Pseudomonas spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pseudomonas spp. serological reagents. 866.3415... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3415 Pseudomonas spp. serological reagents. (a) Identification. Pseudomonas spp. serological reagents are devices that...

  19. 21 CFR 866.3350 - Leptospira spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Leptospira spp. serological reagents. 866.3350... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3350 Leptospira spp. serological reagents. (a) Identification. Leptospira spp. serological reagents are devices that...

  20. 21 CFR 866.3500 - Rickettsia serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rickettsia serological reagents. 866.3500 Section... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3500 Rickettsia serological reagents. (a) Identification. Rickettsia serological reagents are devices that consist of antigens...

  1. 21 CFR 660.25 - Potency tests without reference preparations.

    Science.gov (United States)

    2010-04-01

    ... recommended for slide tests or microplate techniques. Blood Grouping Reagent recommended for slide test... Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood Grouping Reagents are not available shall be tested for potency by a method approved by the Director...

  2. Production of reagents for cleaning fluids

    Energy Technology Data Exchange (ETDEWEB)

    Grunberg, I V; Korostyleva, R N; Pytel, S P; Spasskii, P I; Titarenko, N K; Trachtenberg, S I; Yushkevich, V I

    1980-10-25

    A method for producing reagents for cleaning fluids is proposed using polymerization of acrylonitril, metachrylate or a mixture of the two in water and saponification of the polymers with alakali. To reduce the consumption of monomers and increase the quality of the reagents, 0.4-1.0 parts humic substances, 0.2-1.0 parts hydrolizate from tanning waste products and 1.2-4.0 parts monomers are added to the reaction medium, followed by copolymerization in an acid medium. The proposed method ensures quality reagents which combine lower water yield with a moderate increase in viscosity when acting on clay solutions. Compared with the current method, this method lowers the consumption of an expensive and hard-to-find monomer 1.2-1.4X for one ton of reagent, which lowers the cost of raw material by 1.3-1.7X. This results in a savings of 195-385 rubles per ton of reagent, 600-1200 thousand at 3000 tons/yr.

  3. Industrial detergent wastewater treatment via fenton reagent

    International Nuclear Information System (INIS)

    Mohd Zairie Mohd Yusuff; Mohd Zulkifli Mohamad Noor; Izirwan Izhab

    2010-01-01

    Production of detergent can generates wastewater containing an organic matter with will consume an oxidation demand, surfactants, suspended solids, fat and oil. Besides, sulfate concentration is high in the most detergent plant effluent because of the sulphonation process that has physiological and toxic effects on marine organisms. Therefore, a research must be conducted to find the solution for this problem. The feasibility of Fentons reagent to treat detergent waste was investigated in this study. The sample of detergent wastewater was taken from FPG Oleo chemicals Sdn. Bhd. This experiment studied the effect of temperature towards the feasibility of Fentons reagent process besides the dosage between hydrogen peroxide (H 2 O 2 ) and ferrous ion (Fe 2+ ) in the reagent. While, evaluated efficiency of Fentons reagent in term of chemical oxygen demand (COD), total suspended solid (TSS) and the turbidity reduction within the experimental design. The result found that overall removal was achieved until 96.2 % in term of COD, 98.1 % in term of TSS and 99.6 % in term of turbidity using Fentons reagent process. Besides, also found that this process is optimum at temperature 35 degree Celsius are able to achieve the Standard A of Parameter Limit of Effluent of Standard A and Standard B were outlined by Department of Environment Malaysia (DOE) based on Environment Quality Act 1974. (author)

  4. Constructing New Bioorthogonal Reagents and Reactions.

    Science.gov (United States)

    Row, R David; Prescher, Jennifer A

    2018-05-15

    Chemical tools are transforming our understanding of biomolecules and living systems. Included in this group are bioorthogonal reagents-functional groups that are inert to most biological species, but can be selectively ligated with complementary probes, even in live cells and whole organisms. Applications of these tools have revealed fundamental new insights into biomolecule structure and function-information often beyond the reach of genetic approaches. In many cases, the knowledge gained from bioorthogonal probes has enabled new questions to be asked and innovative research to be pursued. Thus, the continued development and application of these tools promises to both refine our view of biological systems and facilitate new discoveries. Despite decades of achievements in bioorthogonal chemistry, limitations remain. Several reagents are too large or insufficiently stable for use in cellular environments. Many bioorthogonal groups also cross-react with one another, restricting them to singular tasks. In this Account, we describe our work to address some of the voids in the bioorthogonal toolbox. Our efforts to date have focused on small reagents with a high degree of tunability: cyclopropenes, triazines, and cyclopropenones. These motifs react selectively with complementary reagents, and their unique features are enabling new pursuits in biology. The Account is organized by common themes that emerged in our development of novel bioorthogonal reagents and reactions. First, natural product structures can serve as valuable starting points for probe design. Cyclopropene, triazine, and cyclopropenone motifs are all found in natural products, suggesting that they would be metabolically stable and compatible with a variety of living systems. Second, fine-tuning bioorthogonal reagents is essential for their successful translation to biological systems. Different applications demand different types of probes; thus, generating a collection of tools that span a continuum of

  5. Reagent for treating clay drilling muds

    Energy Technology Data Exchange (ETDEWEB)

    Tkachenko, P V; Leshchinskiy, P A; Shnaper, B I; Zinchuk, I F; Zlobin, V P

    1982-01-01

    A reagent is proposed for treating clay drilling muds. It contains lignite, caustic soda and modifying agent. It is distinguished by the fact that in order to reduce the cost of the reagent with simultaneous decrease in the viscosity and static shear stress of the drilling mud, it additionally contains iron sulfate, and the modifying agent contained is wastes of carbonic acid production with the following ratio of components (parts by weight): lignite 10.0-15.0, caustic soda 2.0-3.0, wastes of carbonic acid production 0.5-0.75; iron sulfate 1.0-2.0.

  6. Improved multiple displacement amplification (iMDA) and ultraclean reagents.

    Science.gov (United States)

    Motley, S Timothy; Picuri, John M; Crowder, Chris D; Minich, Jeremiah J; Hofstadler, Steven A; Eshoo, Mark W

    2014-06-06

    Next-generation sequencing sample preparation requires nanogram to microgram quantities of DNA; however, many relevant samples are comprised of only a few cells. Genomic analysis of these samples requires a whole genome amplification method that is unbiased and free of exogenous DNA contamination. To address these challenges we have developed protocols for the production of DNA-free consumables including reagents and have improved upon multiple displacement amplification (iMDA). A specialized ethylene oxide treatment was developed that renders free DNA and DNA present within Gram positive bacterial cells undetectable by qPCR. To reduce DNA contamination in amplification reagents, a combination of ion exchange chromatography, filtration, and lot testing protocols were developed. Our multiple displacement amplification protocol employs a second strand-displacing DNA polymerase, improved buffers, improved reaction conditions and DNA free reagents. The iMDA protocol, when used in combination with DNA-free laboratory consumables and reagents, significantly improved efficiency and accuracy of amplification and sequencing of specimens with moderate to low levels of DNA. The sensitivity and specificity of sequencing of amplified DNA prepared using iMDA was compared to that of DNA obtained with two commercial whole genome amplification kits using 10 fg (~1-2 bacterial cells worth) of bacterial genomic DNA as a template. Analysis showed >99% of the iMDA reads mapped to the template organism whereas only 0.02% of the reads from the commercial kits mapped to the template. To assess the ability of iMDA to achieve balanced genomic coverage, a non-stochastic amount of bacterial genomic DNA (1 pg) was amplified and sequenced, and data obtained were compared to sequencing data obtained directly from genomic DNA. The iMDA DNA and genomic DNA sequencing had comparable coverage 99.98% of the reference genome at ≥1X coverage and 99.9% at ≥5X coverage while maintaining both balance

  7. On-line neutron activation analyzers

    International Nuclear Information System (INIS)

    Flahaut, V.; Colmon, A.

    1999-01-01

    A neutronic analyser has been designed to determine the composition of the flow of raw materials entering a cement factory on the conveyor belt. This new system gives a reliable analysis of the whole cargo that outdates the sampling or the usual surface analysis based on fluorescence spectrometry. The accuracy is about 1%.The neutrons interact with the materials on an average depth of 25 cm and are absorbed by nuclei, these nuclei produce photons whose energy is characteristic of the chemical element itself. The composition can be deduced by measuring the number of photons emitted and their energy. The analysis is made on-line and can concern the search for about 10 compounds. In the case of cement the list of compounds is: SiO 2 , CaO, Al 2 O 3 , Fe 2 O 3 , MgO, Na 2 O, TiO 2 , S, Mn 2 O 3 , K 2 O, and H 2 O. The neutron generator involves a deuterium ion source whose deuterium ions are accelerated by means of an electrical field and impinge on a tritiated target, the nuclear reactions between deuterium and tritium produce 14 MeV neutrons. This neutron analysing technique can be adapted to any need of on-line composition determination. (A.C.)

  8. On-Line Monitoring of Instrument Channel Performance: Volume 3: Applications to Nuclear Power Plant Technical Specification Instrumentation

    International Nuclear Information System (INIS)

    Davis, E.; Rasmussen, B.

    2004-01-01

    This report is a guide for a technical specification change submittal and subsequent implementation of on-line monitoring for safety-related applications. This report is the third in a three-volume set. Volume 1, ''Guidelines for Model Development and Implementation'', presents the various tasks that must be completed to prepare models for and to implement an on-line monitoring system

  9. A Snippet of Grignard Reagent's History

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 18; Issue 8. A Snippet of Grignard Reagent's History. Sujan Singh Dua. Classroom Volume 18 Issue 8 August 2013 pp 777-780. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/018/08/0777-0780. Keywords.

  10. USE OF FENTON'S REAGENT AS A DISINFECTANT

    Science.gov (United States)

    Combined sewage samples obtained from a wastewater treatment facility were disinfected by the Fenton's Reagent of several different compositions. The pre-settled samples contained both suspended solids (SS) and dissolved organic carbon (DOC) at concentrations of 28 and 290 mg/L,...

  11. [A stable reagent for the-single stage determination of inorganic phosphate].

    Science.gov (United States)

    Pupyshev, A B

    1991-01-01

    A recipe of a simple reagent for phosphorus detection has been developed, consisting of ammonium molybdate (4 mM), sulfuric acid (0.2 N), and Tween-80 (0.2%). The developing phosphate staining may be registered in 15 min at a wavelength of 350 nm. The product molar extinction is equal to 1.20.10(4) M-1.cm-1, this being close to that of molybdic blue. Phosphate staining is characterized by the stability of results and insensitivity to the presence of a number of substances used in enzymology. The prepared reagent is fit for experiments within a fortnight if stored in the cold.

  12. On line nuclear orientation: opportunity and challenge

    International Nuclear Information System (INIS)

    Stone, N.J.

    1985-01-01

    The development of the on-line nuclear orientation (OLNO) technique is reviewed. The present potential of the technique is discussed in the light of the attainable temperatures, the use of ion implantation and the required isotope flux. Limitations associated with spin-lattice relaxation are considered in some detail and a survey of accessible nuclei is presented. An outline comparison is given between OLNO and other methods for producing orientation of nuclei, for measuring nuclear spins and static moments and for the study of level structure and transition probabilities. The conclusion is drawn that the method in its present form has extensive potential over a wide range of nuclei. Future prospects for in-beam polarisation giving access to nuclei of shorter half lives are referred to briefly. (Auth.)

  13. An on-line diagnostic expert system

    International Nuclear Information System (INIS)

    Felkel, L.

    1987-01-01

    As experience with on-line information systems, experts systems and artificial intelligence tools grows, the authors retreat from the first euphoria that AI could help them solve the problem they were unable to solve with conventional programming. The major effort of the development time goes into building the knowledge-base. There is no such thing as a generic knowledge-base for nuclear power plants as there is, for example, for the diagnosis of a Boeing 747 aircraft. AI-methods, tools and hardware are still in a state which does not optimally lend itself to real-time application. The ability of developing prototype systems to investigate variants otherwise too costly to justify is one advantage that the authors gladly accept. Last, but no least the tools provide a flexible and adaptable user interface (desktop window systems) etc. The development of such tools in a project would be prohibitive and room for experimentation would be limited

  14. On-Line Algorithms and Reverse Mathematics

    Science.gov (United States)

    Harris, Seth

    In this thesis, we classify the reverse-mathematical strength of sequential problems. If we are given a problem P of the form ∀X(alpha(X) → ∃Zbeta(X,Z)) then the corresponding sequential problem, SeqP, asserts the existence of infinitely many solutions to P: ∀X(∀nalpha(Xn) → ∃Z∀nbeta(X n,Zn)). P is typically provable in RCA0 if all objects involved are finite. SeqP, however, is only guaranteed to be provable in ACA0. In this thesis we exactly characterize which sequential problems are equivalent to RCA0, WKL0, or ACA0.. We say that a problem P is solvable by an on-line algorithm if P can be solved according to a two-player game, played by Alice and Bob, in which Bob has a winning strategy. Bob wins the game if Alice's sequence of plays 〈a0, ..., ak〉 and Bob's sequence of responses 〈 b0, ..., bk〉 constitute a solution to P. Formally, an on-line algorithm A is a function that inputs an admissible sequence of plays 〈a 0, b0, ..., aj〉 and outputs a new play bj for Bob. (This differs from the typical definition of "algorithm", though quite often a concrete set of instructions can be easily deduced from A.). We show that SeqP is provable in RCA0 precisely when P is solvable by an on-line algorithm. Schmerl proved this result specifically for the graph coloring problem; we generalize Schmerl's result to any problem that is on-line solvable. To prove our separation, we introduce a principle called Predictk(r) that is equivalent to -WKL0 for standard k, r.. We show that WKL0 is sufficient to prove SeqP precisely when P has a solvable closed kernel. This means that a solution exists, and each initial segment of this solution is a solution to the corresponding initial segment of the problem. (Certain bounding conditions are necessary as well.) If no such solution exists, then SeqP is equivalent to ACA0 over RCA 0 + ISigma02; RCA0 alone suffices if only sequences of standard length are considered. We use different techniques from Schmerl to prove

  15. On line protection systems for induction motors

    International Nuclear Information System (INIS)

    Colak, I.; Celik, H.; Sefa, I.; Demirbas, S.

    2005-01-01

    Protection of induction motors is very important since they are widely used in industry for many applications due to their high robustness, reliability, low cost and maintenance, high efficiency and long service life. So, protecting these motors is crucial for operations. This paper presents a combined protection approach for induction motors. To achieve this, the electrical values of the induction motor were measured with sensitivity ±1% through a data acquisition card and processed with software developed in Visual C++. An on line protection system for induction motors was achieved easily and effectively. The experimental results have shown that the induction motor was protected against the possible problems faced during the operation. The software developed for this protection provides flexible and reliable media for operators and their motors. It is expected that the motor protection achieved in this study might be faster than the classical techniques and also may be applied to larger motors easily after small modifications of the software

  16. Aprender a innovar: una experiencia on line

    Directory of Open Access Journals (Sweden)

    Joaquín MORENO MARCHAL

    2014-11-01

    Full Text Available La creatividad y la innovación se han convertido en recursos clave en la denominada sociedad del conocimiento, que bien podría ser también llamada sociedad de la innovación. Pero innovar es una actividad compleja, que integra la aplicación de múltiples capacidades, el pensamiento divergente y convergente, la gestión de equipos humanos, la comunicación. Ahora bien, a innovar se puede, y se debe, aprender. Aprender a innovar es un reto y también una obligación para el conjunto del sistema educativo en todos sus niveles. Partiendo de estas consideraciones este trabajo expone una experiencia de aprendizaje de la creatividad y de la innovación a través de un curso totalmente on line basado en la plataforma MOODLE, en el marco del Programa de Formación Permanente de la Universidad de Cádiz. Se presenta un modelo del proceso de innovación, denominado CREALAB, de elaboración propia. Este modelo se ha utilizado como base del proceso de aprendizaje de la creatividad y de la innovación y en el diseño del curso, está organizado en torno a actividades y tiene un carácter iterativo y realimentado. Se presentan además el conjunto del diseño metodológico y los resultados obtenidos en las dos ediciones celebradas hasta el momento. El diseño del curso totalmente on line y los resultados alcanzados permiten estimar un alto potencial de aplicación, tanto a nivel personal como a nivel organizacional.

  17. Polymer-supported reagents with enhanced metal ion recognition: Application to separations science

    International Nuclear Information System (INIS)

    Alexandratos, S.D.

    1993-01-01

    The design and development of polymer-supported reagents with ever-increasing specificities for targeted metal ions remains an important areas of research. The need for efficient separation schemes for both ions and molecules has been outlined in a report by the National Research Council (King) and will gain increased emphasis as environmental restoration is pursued. Polymer-supported reagents are unique in their ability to be applied in an environmentally benign manner to a host of challenges. Such reagents, in the form of beads, can be applied to continuous separation processes ranging from the removal of metal ions in water to the recovery of medicinal drugs produced through biotechnological means. The application of polymer-supported reagents to metal ion separations still requires developing a fundamental understanding of ligand-metal interactions, the role of the polymer in those interactions, and the methods of synthesizing such polymeric reagents in a readily applicable form. Ion exchange resins with sulfonic acid ligands are the prototypical polymer-supported reagents, and their properties have been exhaustively studied (Helfferich). The high acidity of the sulfonic acid group, however, precludes much selectivity, and it displays a very limited range of reaction free energy values with different metal ions (Boyd et al.). The carboxylic acid ligand, present in the acrylate resins, is more selective, though its weak acidity requires relatively high pH solutions for it to be effective. Research has thus been focused on the preparation of polymer-supported reagents with high levels of specificity for targeted metal ions

  18. On-line monitoring of monoclonal antibody formation in high density perfusion culture using FIA.

    Science.gov (United States)

    Fenge, C; Fraune, E; Freitag, R; Scheper, T; Schügerl, K

    1991-05-01

    An automated flow injection system for on-line analysis of proteins in real fermentation fluids was developed by combining the principles of stopped-flow, merging zones flow injection analysis (FIA) with antigen-antibody reactions. IgG in the sample reacted with its corresponding antibody (a-IgG) in the reagent solution. Formation of insoluble immunocomplexes resulted in an increase of the turbidity which was determined photometrically. This system was used to monitor monoclonal antibody production in high cell density perfusion culture of hybridoma cells. Perfusion was performed with a newly developed static filtration unit equipped with hydrophilic microporous tubular membranes. Different sampling devices were tested to obtain a cell-free sample stream for on-line product analysis of high molecular weight (e.g., monoclonal antibodies) and low molecular weight (e.g., glucose, lactate) medium components. In fermentation fluids a good correlation (coefficient: 0.996) between the FIA method and an ELISA test was demonstrated. In a high density perfusion cultivation process mAb formation was successfully monitored on-line over a period of 400 h using a reliable sampling system. Glucose and lactate were measured over the same period of time using a commercially available automatic analyser based on immobilized enzyme technology.

  19. 21 CFR 660.30 - Reagent Red Blood Cells.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Reagent Red Blood Cells. 660.30 Section 660.30...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.30 Reagent Red Blood Cells. (a) Proper name and definition. The proper name of the product shall be...

  20. 21 CFR 866.3255 - Escherichia coli serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Escherichia coli serological reagents. 866.3255... coli serological reagents. (a) Identification. Escherichia coli serological reagents are devices that consist of antigens and antisera used in serological tests to identify Escherichia coli from cultured...

  1. 21 CFR 864.8100 - Bothrops atrox reagent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bothrops atrox reagent. 864.8100 Section 864.8100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8100 Bothrops atrox reagent. (a...

  2. 21 CFR 864.8540 - Red cell lysing reagent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Red cell lysing reagent. 864.8540 Section 864.8540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8540 Red cell lysing reagent...

  3. On-line maintenance at Cofrentes NPP

    International Nuclear Information System (INIS)

    Roldan Vilches, J.; Moreno Matarranz, M. A.; Hermana Mendioroz, I.

    1998-01-01

    Cofrentes NPP has begun in 1997 activities related to At Power Preventive Maintenance over trains or systems which lead to a voluntary entry in a Limitative Condition of Operation (LCO) of the Technical Specifications. From others benefits, this program ha improved the risk management and the staff's knowledge over the functions and safety implications of the different systems, the better exploit of the resources, the co-ordination of the different organisations involved (Maintenance an Operation) and the reductions of works during shutdowns. Previous to each work, a feasibility study analyzes qualitative and quantitative (PSA), using the Risk Monitor, the implications on safety of all the tasks, assuring that the global safety of the Plant is always maintained. Tech. Spec. are analyzed in detail and also are analyzed situations of simultaneous unavailabilities of systems which could lead to a high risk situation. Two different risk controls are defined (punctual and accumulated) to assure that high risk situations will not be given. Finally, historical risk profile is analyzed to assure that the accumulated risk increase is not significant. Risk Monitor helps staff in the schedule and follow-up of the activities of On-Line Maintenance. Each one of the tasks are deeply planned and harshly analyzed and are carried out by high qualified workers. By the moment, this program is running with fully satisfaction on the Plant. (Author)

  4. SOL: INNOVACIÓN ON-LINE

    Directory of Open Access Journals (Sweden)

    Rubén Faúndez

    2007-11-01

    Full Text Available Las aplicaciones de simulación tienden a ser cada vez más cercanas a usuarios e industrias. Sin embargo, muchas de ellas no poseen ni la capacidad ni el conocimiento como para desarrollar internamente sus modelos de simulación. Por este motivo, y como una forma de apoyar la toma de decisiones basándose en modelos de simulación, se presenta la plataforma SOL (Simulación On Line. La metodología completa de trabajo, así como la interacción entre SOL, Empresa y Asesor, son presentadas. Su base de datos, los niveles de usuarios, sus funcionalidades, y la creación automatizada de información grafica y visual, también son explicadas. En el caso de aplicación, el uso de SOL para apoyar la toma de decisiones en una operación de movimiento de material, permite a los tomadores de decisión acceder a análisis robustos basados en información extraída de los modelos de simulación. SOL, al almacenar información, funcionar vía web, generar análisis automatizados y crear visualizaciones, permite cumplir con las expectativas de los usuarios respecto a una solución integral en simulación.

  5. On-Line Impact Load Identification

    Directory of Open Access Journals (Sweden)

    Krzysztof Sekuła

    2013-01-01

    Full Text Available The so-called Adaptive Impact Absorption (AIA is a research area of safety engineering devoted to problems of shock absorption in various unpredictable scenarios of collisions. It makes use of smart technologies (systems equipped with sensors, controllable dissipaters and specialised tools for signal processing. Examples of engineering applications for AIA systems are protective road barriers, automotive bumpers or adaptive landing gears. One of the most challenging problems for AIA systems is on-line identification of impact loads, which is crucial for introducing the optimum real-time strategy of adaptive impact absorption. This paper presents the concept of an impactometer and develops the methodology able to perform real-time impact load identification. Considered dynamic excitation is generated by a mass M1 impacting with initial velocity V0. An analytical formulation of the problem, supported with numerical simulations and experimental verifications is presented. Two identification algorithms based on measured response of the impacted structure are proposed and discussed. Finally, a concept of the AIA device utilizing the idea of impactometer is briefly presented.

  6. Application of on-line analytical processing technique in accelerator

    International Nuclear Information System (INIS)

    Xie Dong; Li Weimin; He Duohui; Liu Gongfa; Xuan Ke

    2005-01-01

    A method of application of the on-line analytical processing technique in accelerator is described, which includes data pre-processing, the process of constructing of data warehouse and on-line analytical processing. (authors)

  7. Simultaneous Determination of Palladium and Platinum by On-line ...

    African Journals Online (AJOL)

    NJD

    using high performance liquid chromatography equipped with an on-line enrichment technique. Prior to ... The on-line enrichment system (Waters Corporation, USA) that was ... Using an appropriate volume (industrial plant effluents 20 mL,.

  8. Mandelazo I as a reagent for Zr(IV) determination

    International Nuclear Information System (INIS)

    Rakha, T.H.; Filip, P.; Stefan, N.

    1984-01-01

    A spectrometric study of the reaction of the Zr(IV) ions with Mandelazo I was carried out. Absorption spectra revealed that the maximum absorption of the zirconium compound appears at a wavelength (316 nm) different from the maxima of the reagent (253 and 390 nm). Beer-Lambert law is followed for zirconium concentrations of the order of 8.8 x 10 -5 M (i.e. 8 μg Zr(IV)/mL). Possible interferences of ions such as Be(II), Cu(II), Zn(II), Al(III), Th(IV), U(VI), Mn(II), Fe(III), Co(II) and Ni(II) were investigated in connection with some masking agents such as SO 4 2- and C 2 O 4 2- . Also, the solid state Zr(IV)- Mandelazo I compound was prepared and characterized by nitrogen and thermogravimetric analyses

  9. Selenium and tellurium reagents in organic synthesis

    International Nuclear Information System (INIS)

    Comasseto, J.V.

    1984-01-01

    A review of the contribution of the University of Sao Paulo (SP, Brazil) to the organic synthesis of selenium and tellurium reagents is made. Major reactions amoung selenium compounds and insaturated substrates, phosphorus, ester enolates as well as the use of phase transference catalysed reactions to produce arylselenolate are described. For tellurium, interactions of its compounds with organic substrates and reactive intermediates (e.g. benzino diazomethane) are reported. (C.L.B.) [pt

  10. Fenton's Reagent. Innovative Technology Summary Report

    International Nuclear Information System (INIS)

    None

    1999-01-01

    The Fenton's Reagent DNAPL treatment process is an in situ oxidation method to destroy DNAPLs in groundwater. Residual industrial solvents, primarily Dense Non-Aqueous Phase Liquids (DNAPLs), are currently the most significant barrier to successful completion of most large groundwater and soil cleanup efforts. DNAPL pools and residues slowly dissolve into surrounding groundwater to create large plumes of organic solvent contamination with concentration levels far above regulatory limits

  11. Influence of visualization on consumption during on-line shopping

    OpenAIRE

    Hictaler, Urška

    2013-01-01

    This diploma work studies the influence of visualization on consumption during on-line shopping. The first part of the thesis starts with key areas of visualization, consumption and on-line shopping. Visualization, areas of use, human perception and ways of product presentation in on-line shops are defined discussed first. Next, consumption, consumers and factors that influence their decisions and satisfaction are defined. The last topic in the first part of the thesis discusses on-line shopp...

  12. A Distributed System for Learning Programming On-Line

    Science.gov (United States)

    Verdu, Elena; Regueras, Luisa M.; Verdu, Maria J.; Leal, Jose P.; de Castro, Juan P.; Queiros, Ricardo

    2012-01-01

    Several Web-based on-line judges or on-line programming trainers have been developed in order to allow students to train their programming skills. However, their pedagogical functionalities in the learning of programming have not been clearly defined. EduJudge is a project which aims to integrate the "UVA On-line Judge", an existing…

  13. Robust on-line monitoring of biogas processes; Robusta maettekniker on-line foer optimerad biogasproduktion

    Energy Technology Data Exchange (ETDEWEB)

    Nordberg, Aake; Hansson, Mikael; Kanerot, Mija; Krozer, Anatol; Loefving, Bjoern; Sahlin, Eskil

    2010-03-15

    Although demand for biomethane in Sweden is higher than ever, many Swedish codigestion plants are presently operated below their designed capacity. Efforts must be taken to increase the loading rate and guarantee stable operation and high availability of the plants. There are currently no commercial systems for on-line monitoring, and due to the characteristics of the material, including corrosion and tearing, robust applications have to be developed. The objective of this project was to identify and study different monitoring technologies with potential for on-line monitoring of both substrate mixtures and anaerobic digester content. Based on the prerequisites and demands at Boraas Energi och Miljoe AB's (BEMAB, the municipal energy and waste utility in the city of Boraas, Sweden) biogas plant, the extent of the problems, measurement variables and possible ways of managing these issues have been identified and prioritized. The substrate mixtures in question have a high viscosity and are inhomogeneous with variation in composition, which calls for further homogenization, dilution and filtration to achieve high precision in the necessary analyses. Studies of using different mixers and mills showed that the particle size (800 mum) needed for on-line COD measurement could not be achieved. The problem of homogenization can be avoided if indirect measurement methods are used. Laboratory tests with NIR (near-infra red spectroscopy) showed that VS can be predicted (R2=0,78) in the interval of 2-9% VS. Furthermore, impedance can give a measurement of soluble components. However, impedance is not sensitive enough to give a good measurement of total TS. Microwave technology was installed at the production plant and showed a faster response to changes in TS than the existing TS-sensor. However, due to technical problems, the evaluation only could be done during a limited period of ten days. BEMAB will continue the measurements and evaluation of the instrument. The

  14. Uptake of DNA by cancer cells without a transfection reagent

    Directory of Open Access Journals (Sweden)

    Yanping Kong

    Full Text Available Abstract Background Cancer cells exhibit elevated levels of glucose uptake and may obtain pre-formed, diet-derived fatty acids from the bloodstream to boost their rapid growth; they may also use nucleic acid from their microenvironment. The study of processing nucleic acid by cancer cells will help improve the understanding of the metabolism of cancer. DNA is commonly packaged into a viral or lipid particle to be transferred into cells; this process is called transfection in laboratory. Cancer cells are known for having gene mutations and the evolving ability of endocytosis. Their uptake of DNAs might be different from normal cells; they may take in DNAs directly from the environment. In this report, we studied the uptake of DNAs in cancer cells without a transfection reagent. Methods A group of DNA fragments were prepared with PCR and labeled with isotope phosphorous-32 to test their uptake by Huh 7 (liver cancer and THLE3 (normal liver cells after incubation overnight by counting radioactivity of the cells’ genomic DNA. Multiple cell lines including breast cancer and lung cancer were tested with the same method. DNA molecules were also labeled with fluorescence to test the location in the cells using a kit of “label it fluorescence in situ hybridization (FISH” from Mirus (USA. Results The data demonstrated that hepatocellular carcinoma cells possess the ability to take in large DNA fragments directly without a transfection reagent whereas normal liver cells cannot. Huh7 and MDA-MB231 cells displayed a significantly higher Rhodamine density in the cytoplasmic phagosomes and this suggests that the mechanism of uptake of large DNA by cancer cells is likely endocytosis. The efficacy of uptake is related to the DNA’s size. Some cell lines of lung cancer and breast cancer also showed similar uptake of DNA. Conclusions In the present study, we have revealed the evidence that some cancer cells, but not nontumorigenic cells, can take DNA

  15. An automated method for the analysis of phenolic acids in plasma based on ion-pairing micro-extraction coupled on-line to gas chromatography/mass spectrometry with in-liner derivatisation

    NARCIS (Netherlands)

    Peters, S.; Kaal, E.; Horsting, I.; Janssen, H.-G.

    2012-01-01

    A new method is presented for the analysis of phenolic acids in plasma based on ion-pairing ‘Micro-extraction in packed sorbent’ (MEPS) coupled on-line to in-liner derivatisation-gas chromatography-mass spectrometry (GC-MS). The ion-pairing reagent served a dual purpose. It was used both to improve

  16. Stability of Loop-Mediated Isothermal Amplification (LAMP) reagents and its amplification efficiency on crude trypanosome DNA templates.

    Science.gov (United States)

    Thekisoe, Oriel M M; Bazie, Raoul S B; Coronel-Servian, Andrea M; Sugimoto, Chihiro; Kawazu, Shin-Ichiro; Inoue, Noboru

    2009-04-01

    This study evaluated the stability of LAMP reagents when stored at 25 degrees C and 37 degrees C, and also assessed its detection efficiency on different DNA template preparations. Accordingly, LAMP using reagents stored at 25 degrees C and 37 degrees C amplified DNA of in vitro cultured T. b. brucei (GUTat 3.1) from day 1 to day 15 of reagent storage. There were no significant differences (P>0.05) in detection sensitivity of LAMP among the reagents stored at 25 degrees C, 37 degrees C and -20 degrees C (recommended storage temperature). LAMP using the reagents stored at above-mentioned temperatures amplified serially diluted DNAs (genomic DNA extracted by phenol-chloroform method, FTA card and hemolysed blood) of T. b. gambiense (IL2343) with high sensitivity. Reactions were conducted on the reagents stored from 1 day to 30 days. LAMP detection sensitivity was poor when fresh blood as DNA template was added directly into reactive solution. Results of this study demonstrated that LAMP has the potential to be used in field conditions for diagnosis of trypanosome infections without being affected by ambient temperatures of tropical and sub-tropical countries where trypanosomosis is endemic.

  17. A Snippet of Grignard Reagent's Histroy There are very few reagents ...

    Indian Academy of Sciences (India)

    IAS Admin

    with bromine, (eq.1). But he failed to notice the formation of phenylmagnesium bromide, because he was using excess bromine which destroyed it. Hence, he could isolate only bromobenzene,. (eq.2). Had he used only one molar equivalent of bromine, perhaps the organomagnesium reagent would bear his name today.

  18. On-line nuclear analysis of coal (Nucoalyzer)

    International Nuclear Information System (INIS)

    Brown, D.R.; Gozani, T.; Bozorgmanesh, H.

    1980-01-01

    Control of quality in the coal process stream is increasingly important in both coal preparation facilities and coal fire power plants. Traditional wet chemistry methods of monitoring coal composition are incapable of providing anything approaching real-time analysis of coal. Typically, small samples of the coal stream are laboratory analyzed and the results made available between a day to a week later. By this time the coal is through the process stream, often already burned and no control is possible. The need of real-time analysis of bulk quantities of the coal has long been recognized and this need motivated Science Applications, Inc. to develop, since 1975, a continuous on-line nuclear analyzer of coal (or CONAC). Over the last three years a prototype of this instrument has undergone extensive testing using 200 pound bulk samples of a wide variety of US coal types. The Nucoalyzer has proven capable of measuring the abundances of all the important elemental constituents of coal along with the ash and calorific value. In the past year the first instrument has been installed and undergone testing at Detroit Edison's Monroe Coal blending facility, where it will control the blending of high and low sulfur coal to meet EPA emission regulations

  19. DOE-EPRI On-Line Monitoring Implementation Guidelines

    International Nuclear Information System (INIS)

    E. Davis, R. Bickford

    2003-01-01

    Industry and EPRI experience at several plants has shown on-line monitoring to be very effective in identifying out-of-calibration instrument channels or indications of equipment-degradation problems. The EPRI implementation project for on-line monitoring has demonstrated the feasibility of on-line monitoring at several participating nuclear plants. The results have been very encouraging, and substantial progress is anticipated in the coming years

  20. Extraction of uranium(6), transuranium elements and europium by bidentate neutral phosphorus- and phosphorus-nitrogen-containing reagents with substituent in methylene bridge

    International Nuclear Information System (INIS)

    Kochetkova, N.E.; Kojro, O.Eh.; Nesterova, N.P.; Medved', T.Ya.; Chmutova, M.K.; Myasoedov, B.F.; Kabachnik, M.I.

    1986-01-01

    The influence of substituents in methylene bridge on solubility, extractivity and selectivity of bidentate neutral phosphorus- and phosphorus-nitrogen-containing reagents in the process of U(6), TUE, Eu extraction has been studied. It is ascertained that hydrogen substitution in the bridge of tetraphenylmethylenediphosphine dioxide (1) causes a decrease in the extractivity of reagent as to TPE, uranium (6) and europium. There is no visible regular relation between basicity and extractivity of substituted reagents. Hydrogen substitution in the bridge of diphenyl[diethylcarbamoylmethyl]phosphine oxide (2) causes a decrease in extractivity of the reagent as to TPE, uranium (6) and europium. In contrast to monodentate neutral reagents, when bidentate neutral reagents are used, sometimes no increase in the reagent extractivity with an increase in its basicity is observed. When fragments restricting the conformation mobility of bidentate reagent molecule are introduced in it (here substituents in methylene bridge), it may result in the violation of the regularity, since of all the factors affecting the reagent extractivity the spatial factor may become the prevailing one. On hydrogen substitution in the bridge of 1 separation factors of practically all (with few exceptions) studied pairs of elements increase. Hydrogen substitution in the bridge of 2 causes an increase in separation factor of U (6) /Am pair and it does not affect the separation factor of Am/Eu pair. Hydrogen substitution in the bridge of 1 and 2 does not result in the preparation of more efficient and considerably more selective reagents for extractive isolation and separation of the elements, but some of the substituted reagents (Cl-substituted 1, for instance) may turn out useful for the element separation

  1. Development of versatile isotopic labeling reagents for profiling the amine submetabolome by liquid chromatography–mass spectrometry

    International Nuclear Information System (INIS)

    Zhou, Ruokun; Huan, Tao; Li, Liang

    2015-01-01

    Highlights: • Two new reagents were developed for chemical isotope labeling mass spectrometry (MS). • They could be used to label amine-containing metabolites in a metabolomic sample. • The labeled metabolites could be detected with much improved sensitivity in MS. • One of the reagents could also help generate useful MS/MS spectra for structural analysis. • These reagents should be useful for quantitative metabolomics. - Abstract: Metabolomic profiling involves relative quantification of metabolites in comparative samples and identification of the significant metabolites that differentiate different groups (e.g., diseased vs. controls). Chemical isotope labeling (CIL) liquid chromatography–mass spectrometry (LC–MS) is an enabling technique that can provide improved metabolome coverage and metabolite quantification. However, chemical identification of labeled metabolites can still be a challenge. In this work, a new set of isotopic labeling reagents offering versatile properties to enhance both detection and identification are described. They were prepared by a glycine molecule (or its isotopic counterpart) and an aromatic acid with varying structures through a simple three-step synthesis route. In addition to relatively low costs of synthesizing the reagents, this reaction route allows adjusting reagent property in accordance with the desired application objective. To date, two isotopic reagents, 4-dimethylaminobenzoylamido acetic acid N-hydroxylsuccinimide ester (DBAA-NHS) and 4-methoxybenzoylamido acetic acid N-hydroxylsuccinimide ester (MBAA-NHS), for labeling the amine-containing metabolites (i.e., amine submetabolome) have been synthesized. The labeling conditions and the related LC–MS method have been optimized. We demonstrate that DBAA labeling can increase the metabolite detectability because of the presence of an electrospray ionization (ESI)-active dimethylaminobenzoyl group. On the other hand, MBAA labeled metabolites can be fragmented

  2. Development of versatile isotopic labeling reagents for profiling the amine submetabolome by liquid chromatography–mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Ruokun; Huan, Tao; Li, Liang, E-mail: Liang.Li@ualberta.ca

    2015-06-30

    Highlights: • Two new reagents were developed for chemical isotope labeling mass spectrometry (MS). • They could be used to label amine-containing metabolites in a metabolomic sample. • The labeled metabolites could be detected with much improved sensitivity in MS. • One of the reagents could also help generate useful MS/MS spectra for structural analysis. • These reagents should be useful for quantitative metabolomics. - Abstract: Metabolomic profiling involves relative quantification of metabolites in comparative samples and identification of the significant metabolites that differentiate different groups (e.g., diseased vs. controls). Chemical isotope labeling (CIL) liquid chromatography–mass spectrometry (LC–MS) is an enabling technique that can provide improved metabolome coverage and metabolite quantification. However, chemical identification of labeled metabolites can still be a challenge. In this work, a new set of isotopic labeling reagents offering versatile properties to enhance both detection and identification are described. They were prepared by a glycine molecule (or its isotopic counterpart) and an aromatic acid with varying structures through a simple three-step synthesis route. In addition to relatively low costs of synthesizing the reagents, this reaction route allows adjusting reagent property in accordance with the desired application objective. To date, two isotopic reagents, 4-dimethylaminobenzoylamido acetic acid N-hydroxylsuccinimide ester (DBAA-NHS) and 4-methoxybenzoylamido acetic acid N-hydroxylsuccinimide ester (MBAA-NHS), for labeling the amine-containing metabolites (i.e., amine submetabolome) have been synthesized. The labeling conditions and the related LC–MS method have been optimized. We demonstrate that DBAA labeling can increase the metabolite detectability because of the presence of an electrospray ionization (ESI)-active dimethylaminobenzoyl group. On the other hand, MBAA labeled metabolites can be fragmented

  3. Unattended reaction monitoring using an automated microfluidic sampler and on-line liquid chromatography.

    Science.gov (United States)

    Patel, Darshan C; Lyu, Yaqi Fara; Gandarilla, Jorge; Doherty, Steve

    2018-04-03

    In-process sampling and analysis is an important aspect of monitoring kinetic profiles and impurity formation or rejection, both in development and during commercial manufacturing. In pharmaceutical process development, the technology of choice for a substantial portion of this analysis is high-performance liquid chromatography (HPLC). Traditionally, the sample extraction and preparation for reaction characterization have been performed manually. This can be time consuming, laborious, and impractical for long processes. Depending on the complexity of the sample preparation, there can be variability introduced by different analysts, and in some cases, the integrity of the sample can be compromised during handling. While there are commercial instruments available for on-line monitoring with HPLC, they lack capabilities in many key areas. Some do not provide integration of the sampling and analysis, while others afford limited flexibility in sample preparation. The current offerings provide a limited number of unit operations available for sample processing and no option for workflow customizability. This work describes development of a microfluidic automated program (MAP) which fully automates the sample extraction, manipulation, and on-line LC analysis. The flexible system is controlled using an intuitive Microsoft Excel based user interface. The autonomous system is capable of unattended reaction monitoring that allows flexible unit operations and workflow customization to enable complex operations and on-line sample preparation. The automated system is shown to offer advantages over manual approaches in key areas while providing consistent and reproducible in-process data. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Collagen proteins exchange O with demineralisation and gelatinisation reagents and also with atmospheric moisture.

    Science.gov (United States)

    von Holstein, Isabella; von Tersch, Matthew; Coutu, Ashley N; Penkman, Kirsty E H; Makarewicz, Cheryl A; Collins, Matthew J

    2018-01-23

    The oxygen isotope composition of collagen proteins is a potential indicator of adult residential location, useful for provenancing in ecology, archaeology and forensics. In acidic solution, proteins can exchange O from carboxylic acid moieties with reagent O. This study investigated whether this exchange occurs during demineralisation and gelatinisation preparation of bone/ivory collagen. EDTA and HCl demineralisation or gelatinisation reagents were made up in waters with different δ 18 O values, and were used to extract collagen from four skeletal tissue samples. Aliquots of extracted collagen were exposed to two different atmospheric waters, at 120°C and ambient temperature, and subsequently dried in a vacuum oven at 40°C or by freeze drying. Sample δ 18 O values were measured by HT/EA pyrolysis-IRMS using a zero-blank autosampler. Collagen samples exchanged O with both reagent waters and atmospheric water, which altered sample δ 18 O values. Exchange with reagent waters occurred in all extraction methods, but was greater at lower pH. Damage to the collagen samples during extraction increased O exchange. The nature of exchange of O with atmospheric water depended on the temperature of exposure: kinetic fractionation of O was identified at 120°C but not at ambient temperature. Exchange was difficult to quantify due to high variability of δ 18 O value between experimental replicates. Studies of δ 18 O values in collagen proteins should avoid extraction methods using acid solutions. This article is protected by copyright. All rights reserved.

  5. The establishment of a WHO Reference Reagent for anti-malaria (Plasmodium falciparum) human serum.

    Science.gov (United States)

    Bryan, Donna; Silva, Nilupa; Rigsby, Peter; Dougall, Thomas; Corran, Patrick; Bowyer, Paul W; Ho, Mei Mei

    2017-08-05

    At a World Health Organization (WHO) sponsored meeting it was concluded that there is an urgent need for a reference preparation that contains antibodies against malaria antigens in order to support serology studies and vaccine development. It was proposed that this reference would take the form of a lyophilized serum or plasma pool from a malaria-endemic area. In response, an immunoassay standard, comprising defibrinated human plasma has been prepared and evaluated in a collaborative study. A pool of human plasma from a malaria endemic region was collected from 140 single plasma donations selected for reactivity to Plasmodium falciparum apical membrane antigen-1 (AMA-1) and merozoite surface proteins (MSP-1 19 , MSP-1 42 , MSP-2 and MSP-3). This pool was defibrinated, filled and freeze dried into a single batch of ampoules to yield a stable source of naturally occurring antibodies to P. falciparum. The preparation was evaluated by an enzyme-linked immunosorbent assay (ELISA) in a collaborative study with sixteen participants from twelve different countries. This anti-malaria human serum preparation (NIBSC Code: 10/198) was adopted by the WHO Expert Committee on Biological Standardization (ECBS) in October 2014, as the first WHO reference reagent for anti-malaria (Plasmodium falciparum) human serum with an assigned arbitrary unitage of 100 units (U) per ampoule. Analysis of the reference reagent in a collaborative study has demonstrated the benefit of this preparation for the reduction in inter- and intra-laboratory variability in ELISA. Whilst locally sourced pools are regularly use for harmonization both within and between a few laboratories, the presence of a WHO-endorsed reference reagent should enable optimal harmonization of malaria serological assays either by direct use of the reference reagent or calibration of local standards against this WHO reference. The intended uses of this reference reagent, a multivalent preparation, are (1) to allow cross

  6. Interactive 3d Landscapes on Line

    Science.gov (United States)

    Fanini, B.; Calori, L.; Ferdani, D.; Pescarin, S.

    2011-09-01

    The paper describes challenges identified while developing browser embedded 3D landscape rendering applications, our current approach and work-flow and how recent development in browser technologies could affect. All the data, even if processed by optimization and decimation tools, result in very huge databases that require paging, streaming and Level-of-Detail techniques to be implemented to allow remote web based real time fruition. Our approach has been to select an open source scene-graph based visual simulation library with sufficient performance and flexibility and adapt it to the web by providing a browser plug-in. Within the current Montegrotto VR Project, content produced with new pipelines has been integrated. The whole Montegrotto Town has been generated procedurally by CityEngine. We used this procedural approach, based on algorithms and procedures because it is particularly functional to create extensive and credible urban reconstructions. To create the archaeological sites we used optimized mesh acquired with laser scanning and photogrammetry techniques whereas to realize the 3D reconstructions of the main historical buildings we adopted computer-graphic software like blender and 3ds Max. At the final stage, semi-automatic tools have been developed and used up to prepare and clusterise 3D models and scene graph routes for web publishing. Vegetation generators have also been used with the goal of populating the virtual scene to enhance the user perceived realism during the navigation experience. After the description of 3D modelling and optimization techniques, the paper will focus and discuss its results and expectations.

  7. INTERACTIVE 3D LANDSCAPES ON LINE

    Directory of Open Access Journals (Sweden)

    B. Fanini

    2012-09-01

    Full Text Available The paper describes challenges identified while developing browser embedded 3D landscape rendering applications, our current approach and work-flow and how recent development in browser technologies could affect. All the data, even if processed by optimization and decimation tools, result in very huge databases that require paging, streaming and Level-of-Detail techniques to be implemented to allow remote web based real time fruition. Our approach has been to select an open source scene-graph based visual simulation library with sufficient performance and flexibility and adapt it to the web by providing a browser plug-in. Within the current Montegrotto VR Project, content produced with new pipelines has been integrated. The whole Montegrotto Town has been generated procedurally by CityEngine. We used this procedural approach, based on algorithms and procedures because it is particularly functional to create extensive and credible urban reconstructions. To create the archaeological sites we used optimized mesh acquired with laser scanning and photogrammetry techniques whereas to realize the 3D reconstructions of the main historical buildings we adopted computer-graphic software like blender and 3ds Max. At the final stage, semi-automatic tools have been developed and used up to prepare and clusterise 3D models and scene graph routes for web publishing. Vegetation generators have also been used with the goal of populating the virtual scene to enhance the user perceived realism during the navigation experience. After the description of 3D modelling and optimization techniques, the paper will focus and discuss its results and expectations.

  8. ON-Line Monitoring of Instrument Channel Performance: Volume 3: Applications to Nuclear Power Plant Technical Specification Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    E Davis, B Rasmussen

    2004-12-31

    This report is a guide for a technical specification change submittal and subsequent implementation of on-line monitoring for safety-related applications. This report is the third in a three-volume set. Volume 1, ''Guidelines for Model Development and Implementation'', presents the various tasks that must be completed to prepare models for and to implement an on-line monitoring system.

  9. 21 CFR 866.3120 - Chlamydia serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3120 Chlamydia... and antisera used in serological tests to identify antibodies to chlamydia in serum. Additionally...

  10. 21 CFR 866.3490 - Rhinovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3490 Rhinovirus... and antisera used in serological tests to identify antibodies to rhinovirus in serum. The...

  11. 21 CFR 866.3240 - Equine encephalomyelitis virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents... these viruses. Equine encephalomyelitis viruses are transmitted to humans by the bite of insects, such...

  12. 21 CFR 866.3165 - Cryptococcus neoformans serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3165... clinical specimens or from cultured isolates derived from clinical specimens. The identification aids in...

  13. 21 CFR 866.3020 - Adenovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3020 Adenovirus... identify adenoviruses directly from clinical specimens. The identification aids in the diagnosis of disease...

  14. 21 CFR 866.3480 - Respiratory syncytial virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3480... respiratory syncytial viruses from clinical specimens or from tissue culture isolates derived from clinical...

  15. 21 CFR 866.3140 - Corynebacterium spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3140.... from clinical specimens. The identification aids in the diagnosis of disease caused by bacteria...

  16. 21 CFR 866.3250 - Erysipelothrix rhusiopathiae serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3250... Erysipelothrix rhusiopathiae from cultured isolates derived from clinical specimens. The identification aids in...

  17. 21 CFR 866.3270 - Flavobacterium spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3270.... from cultured isolates derived from clinical specimens. The identification aids in the diagnosis of...

  18. 21 CFR 866.3205 - Echovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3205 Echovirus... echoviruses from clinical specimens or from tissue culture isolates derived from clinical specimens. The...

  19. 21 CFR 866.3110 - Campylobacter fetus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3110 Campylobacter... clinical specimens or cultured isolates derived from clinical specimens. The identification aids in the...

  20. 21 CFR 866.3320 - Histoplasma capsulatum serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3320... capsulatum from clinical specimens or cultured isolates derived from clinical specimens. The identification...

  1. 21 CFR 866.3340 - Klebsiella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3340 Klebsiella... from clinical specimens. The identification aids in the diagnosis of diseases caused by bacteria...

  2. 21 CFR 866.3930 - Vibrio cholerae serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3930 Vibrio... from cultured isolates derived from clinical specimens. The identification aids in the diagnosis of...

  3. 21 CFR 866.3010 - Acinetobacter calcoaceticus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3010... this bacterium from cultured isolates derived from clinical specimens. The identification aids in the...

  4. 21 CFR 866.3370 - Mycobacterium tuberculosis immunofluorescent reagents.

    Science.gov (United States)

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents... used to identify Mycobacterium tuberculosis directly from clinical specimens. The identification aids...

  5. The activity-integrated method for quality assessment of reduning injection by on-line DPPH-CE-DAD.

    Directory of Open Access Journals (Sweden)

    Yan-xu Chang

    Full Text Available A sensitive on-line DPPH-CE-DAD method was developed and validated for both screening and determining the concentration of seven antioxidants of Reduning injection. The pH and concentrations of buffer solution, SDS, β-CD and organic modifier were studied for the detection of DPPH and seven antioxidants. By on-line mixing DPPH and sample solution, a DPPH-CE method for testing the antioxidant activity of the complex matrix was successfully established and used to screen the antioxidant components of Reduning injection. Then, antioxidant components including caffeic acid, isochlorogenic acid A, isochlorogenic acid B, isochlorogenic acid C, chlorogenic acid, neochlorogenic acid and cryptochlorogenic acid were quantified by the newly established CE-DAD method. Finally, the total antioxidant activity and the multiple active components were selected as markers to evaluate the quality of Reduning injection. The results demonstrated that the on-line DPPH-CE-DAD method was reagent-saving, rapid and feasible for on-line simultaneous determination of total pharmacological activity and contents of multi-components samples. It was also a powerful method for evaluating the quality control and mechanism of action of TCM injection.

  6. Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications

    CSIR Research Space (South Africa)

    Smith, S

    2016-02-01

    Full Text Available Lab-on-a-chip devices are often applied to point-of-care diagnostic solutions as they are low-cost, compact, disposable, and require only small sample volumes. For such devices, various reagents are required for sample preparation and analysis and...

  7. New data on masking reagents in complexometry

    International Nuclear Information System (INIS)

    Yurist, I.M.; Talmud, M.M.; Zajtsev, P.M.

    1985-01-01

    Recent literature data on employing inorganic and organic oxygen-, nitrogen- and sulfur-containing substances as masking reagents (MR) in complexonometry of alkali earths, rare earths and transition elements are reviewed for the period of 1971-1983. Effectiveness of any type of MR is shown to be dependent on the electron configuration of a cation being masked. Sr, La, Th, V(6), Zr, Hf, V(5), Nb(5), Ta(5), Mo(6), W(6) a.o. are masked by oxygen-containing ligands. Zn, Cd, Fe(2, 3), Co(2, 3), Ni, etc. are masked by nitrogen- and sulfur-bearing ligands. Thiocompounds mask mainly In, Tl(3), Sn(2), Pb, Bi

  8. Algorithms for the on-line travelling salesman

    NARCIS (Netherlands)

    Ausiello, G.; Feuerstein, E.; Leonardi, S.; Stougie, L.; Talamo, M.

    1999-01-01

    In this paper the problem of efficiently serving a sequence of requests presented in an on-line fashion located at points of a metric space is considered. We call this problem the On-Line Travelling Salesman Problem (OLTSP). It has a variety of relevant applications in logistics and robotics. We

  9. An algorithm for on-line price discrimination

    NARCIS (Netherlands)

    D.D.B. van Bragt; D.J.A. Somefun (Koye); E. Kutschinski; J.A. La Poutré (Han)

    2002-01-01

    textabstractThe combination of on-line dynamic pricing with price discrimination can be very beneficial for firms operating on the Internet. We therefore develop an on-line dynamic pricing algorithm that can adjust the price schedule for a good or service on behalf of a firm. This algorithm (a

  10. On-Line Voltage Stability Assessment based on PMU Measurements

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; P. Da Silva, Luiz C.; Nielsen, Arne Hejde

    2009-01-01

    This paper presents a method for on-line monitoring of risk voltage collapse based on synchronised phasor measurement. As there is no room for intensive computation and analysis in real-time, the method is based on the combination of off-line computation and on-line monitoring, which are correlat...

  11. From Off-line to On-line Handwriting Recognition

    NARCIS (Netherlands)

    Lallican, P.; Viard-Gaudin, C.; Knerr, S.

    2004-01-01

    On-line handwriting includes more information on time order of the writing signal and on the dynamics of the writing process than off-line handwriting. Therefore, on-line recognition systems achieve higher recognition rates. This can be concluded from results reported in the literature, and has been

  12. On-line Learning of Prototypes and Principal Components

    NARCIS (Netherlands)

    Biehl, M.; Freking, A.; Hölzer, M.; Reents, G.; Schlösser, E.; Saad, David

    1998-01-01

    We review our recent investigation of on-line unsupervised learning from high-dimensional structured data. First, on-line competitive learning is studied as a method for the identification of prototype vectors from overlapping clusters of examples. Specifically, we analyse the dynamics of the

  13. Development of IRMA reagent and methodology for PSA

    International Nuclear Information System (INIS)

    Najafi, R.

    1997-01-01

    The PSA test is a solid phase two-site immunoassay. Rabbit anti PSA is coated or bound on surface of solid phase and monoclonal anti PSA labeled with 1-125. The PSA molecules present in the standard solution or serum are 'Sandwiched' between the two antibodies. After formation of coated antibody-antigen-labeled antibody complex, the unbound labeled antibody will removed by washing. The complex is measured by gamma counter. The concentration of analyte is proportional to the counts of test sample. In order to develop kits for IRMA PSA, it should be prepared three essential reagents Antibody coated solid phase, labeled antibody, standards and finally optimizing them to obtain an standard curve fit to measure specimen PSA in desired range of concentration. The type of solid phase and procedure(s) to coat or bind to antibody, is still main debatable subject in development and setting up RIA/IRMA kits. In our experiments, polystyrene beads, because of their easy to coat with antibody as well as easy to use, can be considered as a desired solid phase. Most antibodies are passively adsorbed to a plastic surface (e.g. Polystyrene, Propylene, and Polyvinyl chloride) from a diluted buffer. The antibody coated plastic surface, then acts as solid phase reagent. Poor efficiency and time required to reach equilibrium and also lack of reproducibility especially batch-to-batch variation between materials, are disadvantages in this simple coating procedure. Improvements can be made by coating second antibody on surface of beads, and reaction between second and primary antibodies. There is also possible to enhance more coating efficiency of beads by using Staphylococcus ureus-Protein A. Protein A is a major component of staphylococcus aureus cell wall which has an affinity for FC segment of immunoglobulin G (IgG) of some species, including human; rabbit; and mice. This property of Staphylococcal Protein A has made it a very useful tool in the purification of classes and subclasses

  14. On-line and bulk analysis for the resource industries

    International Nuclear Information System (INIS)

    Lim, C.S.; Sowerby, B.D.; Tickner, J.R.; Madsen, I.C.

    2001-01-01

    Nuclear techniques are the basis of many CSIRO on-line and bulk analysis systems that are now widely used in the mineral and energy industries. The continuous analysis and rapid response of these systems have led to improved control of mining, processing and blending operations. This paper reviews recent developments in neutron, gamma-ray and X-ray techniques for on-line and bulk analysis by CSIRO Minerals including neutron techniques for the on-conveyor belt determination of the composition of cement raw meal, the on-line analysis of composition in pyrometallurgical applications, the on-conveyor belt determination of ash in coal, and the rapid and accurate determination of gold in bulk laboratory samples. The paper also discusses a new gamma-ray technique for the on-line determination of ash in coal and the application of X-ray diffraction techniques for the on-line determination of mineralogy in the cement industry

  15. Effect of reagent charge on the labeling of erythrocyte membrane proteins by photoactivated reagents

    International Nuclear Information System (INIS)

    Schaeffer, J.C.; Hakimian, R.; Shimer, M.L.

    1986-01-01

    Leaky erythrocyte ghosts were labeled with 3 H-[2-(4-azido-2-nitroanilino)ethyl]trimethylammonium iodide (cationic label) or 3 H-N-(4-azido-2-nitrophenyl)-β-alanine (anionic label). After the membranes were thoroughly washed, seven times as much cationic label was associated with the membranes as anionic label at 5 μM, whereas at 50 μM the cationic label was favored 15-fold. The distribution of label in the membrane proteins was ascertain by SDS-gel electrophoresis followed by autoradiography. At 50 μM cationic label, erythrocyte membrane protein bands 1,2,3,4.2, and 5 were intensely labeled, while band 6 was labeled weakly. At 5 μM cationic label, bands 1 and 4.2 were heavily labeled, while 2,3 and 5 were labeled less well. At both 50 μM and 5 μM anionic label, bands 1 and 6 were most prominently labeled. Bands 2,3,4.2 and 5 were labeled also at 50 μM, but they were labeled only very weakly at 5 μM. Band 4.1 was labeled very poorly if at all by either reagent. A mixture of the reagents gave an additive pattern. Thus, the charge and concentration of these reagents appear to play a major role in their ability to label membrane proteins indiscriminately. Because these reagents contain the same chromophore, 4-azido-2-nitroaniline, and differ mainly only in their charge, they may prove useful in assessing the location of charged sites on proteins in supramolecular complexes

  16. Inactivation and stability of viral diagnostic reagents treated by gamma radiation

    International Nuclear Information System (INIS)

    White, L.A.; Freeman, C.Y.; Hall, H.E.; Forrester, B.D.

    1990-01-01

    The objective of this study was to apply the pertinent findings from gamma inactivation of virus infectivity to the production of high quality diagnostic reagents. A Gammacell 220 was used to subject 38 viruses grown in either susceptible tissue cultures or embryonated chicken eggs to various doses of gamma radiation from a cobalt-60 source. The radiation required to reduce viral infectivity was 0.42 to 3.7 megarads (Mrad). The effect of gamma treatment on the antigenic reactivity of reagents for the complement fixation (CF), hemagglutination (HA) and neuraminadase assays was determined. Influenza antigens inactivated with 1.7 Mrad displayed comparable potency, sensitivity, specificity and stability to those inactivated by standard procedures with beta-propiolactone (BPL). Significant inactivation of influenza N1 and B neuraminidase occurred with >2.4 Mrad radiation at temperatures above 4 0 C. All 38 viruses were inactivated, and CF or HA antigens were prepared successfully. Antigenic potency remained stable with all antigens for 3 years and with 83% after 5 years storage. Influenza HA antigens evaluated after 9 years of storage demonstrated 86% stability. Gamma radiation is safer than chemical inactivation procedures and is a reliable and effective replacement for BPL in preparing diagnostic reagents. (author)

  17. Inactivation and stability of viral diagnostic reagents treated by gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    White, L A; Freeman, C Y; Hall, H E; Forrester, B D [Department of Health and Human Services, Atlanta, GA (USA)

    1990-10-01

    The objective of this study was to apply the pertinent findings from gamma inactivation of virus infectivity to the production of high quality diagnostic reagents. A Gammacell 220 was used to subject 38 viruses grown in either susceptible tissue cultures or embryonated chicken eggs to various doses of gamma radiation from a cobalt-60 source. The radiation required to reduce viral infectivity was 0.42 to 3.7 megarads (Mrad). The effect of gamma treatment on the antigenic reactivity of reagents for the complement fixation (CF), hemagglutination (HA) and neuraminadase assays was determined. Influenza antigens inactivated with 1.7 Mrad displayed comparable potency, sensitivity, specificity and stability to those inactivated by standard procedures with beta-propiolactone (BPL). Significant inactivation of influenza N1 and B neuraminidase occurred with >2.4 Mrad radiation at temperatures above 4{sup 0}C. All 38 viruses were inactivated, and CF or HA antigens were prepared successfully. Antigenic potency remained stable with all antigens for 3 years and with 83% after 5 years storage. Influenza HA antigens evaluated after 9 years of storage demonstrated 86% stability. Gamma radiation is safer than chemical inactivation procedures and is a reliable and effective replacement for BPL in preparing diagnostic reagents. (author).

  18. Synthesis of netlike gold nanoparticles using ampicillin as a stabilizing reagent and its application

    International Nuclear Information System (INIS)

    Song, Y.Z.; Zhou, J.F.; Song, Y.; Cheng, Z.P.; Xu, J.

    2012-01-01

    Graphical abstract: Electrochemical deposition of netlike gold nanoparticles (GNPs) on the surface of glassy carbon electrode and preparation of netlike GNPs in aqueous solution using ampicillin as a stabilizing reagent were proposed. The catalytic properties of netlike gold nanoparticles on the glassy carbon electrode for dopamine were demonstrated. The results indicate that the netlike gold nanoparticle modified electrode has an excellent repeatability and reproducibility. Display Omitted Highlights: ► Synthesis of netlike gold nanoparticles using ampicillin as a stabilizing reagent. ► Excellent repeatability and reproducibility of netlike gold nanoparticle modified glassy carbon electrode. ► The catalytic properties of netlike gold nanoparticle for dopamine. -- Abstract: Electrochemical deposition of netlike gold nanoparticles on the surface of glassy carbon electrode and preparation of netlike GNPs in aqueous solution using ampicillin as a stabilizing reagent were proposed. The netlike gold nanoparticles were characterized by scanning electron microscope, transmission electron microscope, infrared spectrometer, UV spectrophotometer, powder X-ray diffractometer and electrochemical analyzer. The catalysis of the netlike gold nanoparticles on the glassy carbon electrode for dopamine was demonstrated. The results indicate that the gold nanoparticle modified electrode has an excellent repeatability and reproducibility.

  19. Physically absorbable reagents-collectors in elementary flotation

    Energy Technology Data Exchange (ETDEWEB)

    S.A. Kondrat' ev; I.G. Bochkarev [Russian Academy of Sciences, Novosibirsk (Russian Federation). Institute of Mining

    2007-09-15

    Based on the reviewed researches held at the Institute of Mining, Siberian Branch, Russian Academy of Sciences, the effect of physically absorbable reagents-collectors on formation of a flotation complex and its stability in turbulent pulp flows in flotation machines of basic types is considered. The basic requirements for physically absorbable reagents-collectors at different flotation stages are established.

  20. 21 CFR 866.3520 - Rubeola (measles) virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rubeola (measles) virus serological reagents. 866... Rubeola (measles) virus serological reagents. (a) Identification. Rubeola (measles) virus serological... to rubeola virus in serum. The identification aids in the diagnosis of measles and provides...

  1. 21 CFR 866.3355 - Listeria spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3355 Listeria spp... from clinical specimens. Additionally, some of these reagents consist of Listeria spp. antisera... clinical specimens. The identification aids in the diagnosis of listeriosis, a disease caused by bacteria...

  2. 21 CFR 866.3550 - Salmonella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3550 Salmonella... isolates derived from clinical specimens. Additionally, some of these reagents consist of antisera... clinical specimens or cultured isolates derived from clinical specimens. The identification aids in the...

  3. Reagents for the assay of cardenolide glycosides and aglycones

    International Nuclear Information System (INIS)

    Wilkinson, S.

    1976-01-01

    Some novel reagents are described for use in the radioimmunoassay of the 3-glycone derivatives of cardenolides (cardiac glycosides) and more especially digoxin, digitoxin, gitoxin, periplocin and lanatosides. Using these reagents these cardenolides and their derivatives may be assayed both in aqueous solution and in urine. A method is also described for performing such assays, including a suitable kit. (U.K.)

  4. 21 CFR 864.8950 - Russell viper venom reagent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Russell viper venom reagent. 864.8950 Section 864.8950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8950 Russell viper venom...

  5. Use of Competition Kinetics with Fast Reactions of Grignard Reagents

    DEFF Research Database (Denmark)

    Holm, Torkil

    2000-01-01

    small.This is concluded from experiments in which results obtained by competition kinetics are compared with results obtained directly by flow stream procedures. A clearer picture of the reactivity ratios is obtained when the highly reactive reagent is highly diluted with its competitor. A fast reagent...

  6. IN-PLACE REGENERATION OF GAC USING FENTON'S REAGENTS

    Science.gov (United States)

    This paper evaluates the feasibility of using Fenton’s reagents for in-place recovery of spent granular activated carbon (GAC). Fenton’s reagents are cycled through spent GAC to degrade sorbed chlorinated hydrocarbons with little loss of carbon capacity. Seven chlorinated compou...

  7. Sample preparation in alkaline media

    International Nuclear Information System (INIS)

    Nobrega, Joaquim A.; Santos, Mirian C.; Sousa, Rafael A. de; Cadore, Solange; Barnes, Ramon M.; Tatro, Mark

    2006-01-01

    The use of tetramethylammonium hydroxide, tertiary amines and strongly alkaline reagents for sample treatment involving extraction and digestion procedures is discussed in this review. The preparation of slurries is also discussed. Based on literature data, alkaline media offer a good alternative for sample preparation involving an appreciable group of analytes in different types of samples. These reagents are also successfully employed in tailored speciation procedures wherein there is a critical dependence on maintenance of chemical forms. The effects of these reagents on measurements performed using spectroanalytical techniques are discussed. Several undesirable effects on transport and atomization processes necessitate use of the method of standard additions to obtain accurate results. It is also evident that alkaline media can improve the performance of techniques such as inductively coupled plasma mass spectrometry and accessories, such as autosamplers coupled to graphite furnace atomic absorption spectrometers

  8. A convenient method to synthesize N-[3H]methyl-N-nitrosocarbamate transfer reagents

    International Nuclear Information System (INIS)

    Mehta, P.; Gold, B.; Konakahara, T.

    1992-01-01

    Activated N-alkyl-N-nitrosocarbamates are useful acyl transfer reagents that are employed in the synthesis of N-alkyl-N-nitrosoureas and related N-nitroso compounds. The nitrosourea products are of chemical and biological interest because they provide access to the in situ generation of highly reactive carbonium type intermediates, which, depending on their structure, can be powerful carcinogens or antineoplastic agents. The availability of radiolabeled nitrosoureas greatly facilitates studies on their chemical and biological activities. Generally, the synthesis of activated nitrosocarbamates requires condensation of radiolabeled alkylisocyanates with the appropriate alcohol. Because radiolabeled alkylisocyanates are not commercially available and/or troublesome to synthesize, we have developed an easy and economical method for preparing N-[ 3 H]methyl-N-nitrosocarbamates suitable for use as transfer reagents utilizing 1,2,2,2-tetrachloroethyl chloroformate and [ 3 H]methylamine hydrochloride as starting materials. (author)

  9. Field-Portable Immunoassay Instruments and Reagents to Measure Chelators and Mobile Forms of Uranium

    International Nuclear Information System (INIS)

    Blake, Diane A.

    2003-01-01

    The goals for the 3-year project period are (1) to test and validate the present uranium sensor and develop protocols for its use at the NABIR Field Research Center; (2) to develop new reagents that will provide superior performance for the present hand-held immunosensor; and (3) to develop new antibodies that will permit this sensor to also measure other environmental contaminants (chromium, mercury, and/or DTPA). Sensor design modifications are underway via international collaborations. New reagents that will provide superior performance for the present hand-held immunosensor are being prepared and tested. New methods have been developed, to produce recombinant forms of metal-specific monoclonal antibodies for use with the sensor. Site-directed mutagenesis experiments are underway to determine the mechanisms of binding. Immunization experiments with sheep and rabbits to develop new recombinant forms of antibodies to metal-chelate complexes (chromium, mercury, and/or DTPA) have been initiated

  10. A convenient method to synthesize N-[[sup 3]H]methyl-N-nitrosocarbamate transfer reagents

    Energy Technology Data Exchange (ETDEWEB)

    Mehta, P.; Gold, B. (Nebraska Univ., Omaha, NE (United States). Eppley Inst. for Research in Cancer); Konakahara, T. (Science Univiversity of Tokyo, Noda, Chiba (Japan). Faculty of Science and Technology)

    1992-11-01

    Activated N-alkyl-N-nitrosocarbamates are useful acyl transfer reagents that are employed in the synthesis of N-alkyl-N-nitrosoureas and related N-nitroso compounds. The nitrosourea products are of chemical and biological interest because they provide access to the in situ generation of highly reactive carbonium type intermediates, which, depending on their structure, can be powerful carcinogens or antineoplastic agents. The availability of radiolabeled nitrosoureas greatly facilitates studies on their chemical and biological activities. Generally, the synthesis of activated nitrosocarbamates requires condensation of radiolabeled alkylisocyanates with the appropriate alcohol. Because radiolabeled alkylisocyanates are not commercially available and/or troublesome to synthesize, we have developed an easy and economical method for preparing N-[[sup 3]H]methyl-N-nitrosocarbamates suitable for use as transfer reagents utilizing 1,2,2,2-tetrachloroethyl chloroformate and [[sup 3]H]methylamine hydrochloride as starting materials. (author).

  11. Reagent-loaded plastic microfluidic chips for detecting homocysteine

    International Nuclear Information System (INIS)

    Suk, Ji Won; Jang, Jae-Young; Cho, Jun-Hyeong

    2008-01-01

    This report describes the preliminary study on plastic microfluidic chips with pre-loaded reagents for detecting homocysteine (Hcy). All reagents needed in an Hcy immunoassay were included in a microfluidic chip to remove tedious assay steps. A simple and cost-effective bonding method was developed to realize reagent-loaded microfluidic chips. This technique uses an intermediate layer between two plastic substrates by selectively patterning polydimethylsiloxane (PDMS) on the embossed surface of microchannels and fixing the substrates under pressure. Using this bonding method, the competitive immunoassay for SAH, a converted form of Hcy, was performed without any damage to reagents in chips, and the results showed that the fluorescent signal from antibody antigen binding decreased as the SAH concentration increased. Based on the SAH immunoassay, whole immunoassay steps for Hcy detection were carried out in plastic microfluidic chips with all necessary reagents. These experiments demonstrated the feasibility of the Hcy immunoassay in microfluidic devices

  12. Understanding on-line community: the affordances of virtual space

    Directory of Open Access Journals (Sweden)

    Karen Ruhleder

    2002-01-01

    Full Text Available Increasing numbers of on-line venues for learning are emerging as virtual communities become more accessible and commonplace. This paper looks at one particular virtual community, an on-line degree programme at the University of Illinois, Urbana-Champaign, which offers an M.S. in Library and Information Science (called LEEP. It draws on a framework presented by Mynatt, et al. (1998, which provides a lens for talking about on-line community as a set of affordances. This framework is applied to illustrate the interactions, artefacts, and expectations that shape this community.

  13. An Approach to On-line Risk Assessment in NPP

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.; O'Brien, J.

    1996-01-01

    Probabilistic Risk Assessment (PRA) can provide safety status information for a plant during different configurations; additional effort is needed to do this in real time for on-line operation. This paper describes an approach to use PRA to achieve these goals. A Risk Assessment On-Line (RAOL) application was developed to monitor maintenance (on-line and planned) activities. RAOL is based on the results from a full-scope PRA, engineering/operational judgment and incorporates a user friendly program interface approach. Results from RAOL can be used by planners or operations to effectively manage the level of risk by controlling the actual plant configuration. (author)

  14. On-line spectroscopy with thermal atomic beams

    International Nuclear Information System (INIS)

    Thibault, C.; Guimbal, P.; Klapisch, R.; Saint Simon, M. de; Serre, J.M.; Touchard, F.; Duong, H.T.; Jacquinot, P.; Juncar, P.

    1981-01-01

    On-line high resolution laser spectroscopy experiments have been performed in which the light from a cw tunable dye laser interacts at right angles with a thermal atomic beam. sup(76-98)Rb, sup(118-145)Cs and sup(208-213)Fr have been studied using the ionic beam delivered by the ISOLDE on-line mass separator at CERN while sup(20-31)Na and sup(38-47)K have been studied by setting the apparaturs directly on-line with the PS 20 GeV proton beam. The principle of the method is briefly explained and some results concerning nuclear structure are given. (orig.)

  15. Comparison of On-Line Maintenance Support Tools

    International Nuclear Information System (INIS)

    Simic, Z.; Follen, S. M.; Mikulicic, V.

    1998-01-01

    Modeling approach to on-line risk monitoring is today in a rapid developing phase. For that reason number of different solutions are available. This paper will attempt to present existing approaches to address on-line risk modeling problem Starting with description of on-line risk monitoring issues in general, then following by presentation of existing software tools (EPRI's Safety Monitor, Equipment Out of Service Monitor, and ORAM-SENTINEL) the current state of the art in this area will be demonstrated. Finally, conclusions and ideas will be outlined. (author)

  16. High throughput screening method for identification of new lipofection reagents.

    Science.gov (United States)

    Regelin, A E; Fernholz, E; Krug, H F; Massing, U

    2001-08-01

    Lipofection, the transfer of genetic material into cells by means of cationic lipids, is of growing interest for in vitro and in vivo approaches. In order to identify ideal lipofection reagents in a HTS, we have developed an automated lipofection method for the transfer of reporter genes into cells and for determination of the lipofection results. The method has specifically been designed and optimized for 96-well microtiter plates and can successfully be carried out by a pipetting robot with accessory equipment. It consists of two separate parts: (1) pretransfection (preparation of liposomes, formation of lipoplexes, and lipoplex transfer to the cells) and (2) posttransfection (determination of the reporter enzyme activity and the protein content of the transfected cells). Individual steps of the lipofection method were specifically optimized - for example, lipoplex formation and incubation time as well as cell lysis, cell cultivating, and the reporter gene assay. The HTS method facilitates characterization of the transfection properties (efficiency and cytotoxicity) of large numbers of (cationic) lipids in various adherent cell types.

  17. On-line methanol sensor system development for recombinant ...

    African Journals Online (AJOL)

    On-line methanol sensor system development for recombinant human serum ... of the methanol sensor system was done in a medium environment with yeast cells ... induction at a low temperature and a pH where protease does not function.

  18. On-line control systems in power plants

    International Nuclear Information System (INIS)

    Freymeyer, P.

    1981-01-01

    This report is a review of on-line control systems as a complex system connected with all problems like, development, planning, degree of automation, economics, service, quality and documentation. (orig.) [de

  19. Why do People Stop Playing On-Line Games?

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana

    2012-01-01

    The recent initial public offering of shares of Zynga, probably the most important on-line game provider, drew interest of potential investors but also of general public to their business model. What the most interested people learned so far is that if Zynga had not changed their accounting...... practice, they would be in red numbers for several months already. This is most likely caused by people stopping to play their games. This paper provides an estimate of what proportion of people, who played on-line games, already stopped playing them. Additionally, it analyzed the reasons why people...... stopped playing on-line games. It also compares Facebook and other on-line games....

  20. The Daresbury On-Line Isotope Separator (DOLIS)

    International Nuclear Information System (INIS)

    Grant, I.S.; Eastham, D.A.; Groves, J.; Tolfree, D.W.L.; Walker, P.M.; Green, V.R.; Rikovska, J.; Stone, N.J.; Hamilton, W.D.

    1987-01-01

    The isotope separator DOLIS, which is on-line to the Daresbury Laboratory's 20-MV tandem accelerator, is used to measure nuclear moments and decay schemes. Separated beams may be collected on a tape and transported to a counting station, implanted directly into a host lattice at on-line temperatures down to less than 10 mK, or allowed to interact with a collinear laser beam. The present status of DOLIS and its ancillary equipment is described

  1. The Daresbury on-line isotope separator (DOLIS)

    International Nuclear Information System (INIS)

    Grant, I.S.; Eastham, D.A.; Groves, J.; Tolfree, D.W.L.; Walker, P.M.; Green, V.R.; Rikovska, J.; Stone, N.J.; Hamilton, W.D.

    1987-01-01

    The isotope separator DOLIS, which is on-line to the Daresbury Laboratory's 20-MV tandem accelerator, is used to measure nuclear moments and decay schemes. Separated beams may be collected on a tape and transported to a counting station, implanted directly into a host lattice at on-line temperatures down to less than 10 mK, or allowed to interact with a collinear laser beam. The present status of DOLIS and its ancillary equipment is described. (orig.)

  2. Considerations in applying on-line IC techniques to BWR's

    International Nuclear Information System (INIS)

    Kaleda, R.J.

    1992-01-01

    Ion-Chromatography (IC) has moved from its traditional role as a laboratory analytical tool to a real time, dynamic, on-line measurement device to follow ppb and sub-ppb concentrations of deleterious impurities in nuclear power plants. Electric Power Research Institute (EPRI), individual utilities, and industry all have played significant roles in effecting the transition. This paper highlights considerations and the evolution in current on-line Ion Chromatography systems. The first applications of on-line techniques were demonstrated by General Electric (GE) under EPRI sponsorship at Rancho Seco (1980), Calvert Cliffs, and McGuire nuclear units. The primary use was for diagnostic purposes. Today the on-line IC applications have been expanded to include process control and routine plant monitoring. Current on-line IC's are innovative in design, promote operational simplicity, are modular for simplified maintenance and repair, and use field-proven components which enhance reliability. Conductivity detection with electronic or chemical suppression and spectrometric detection techniques are intermixed in applications. Remote multi-point sample systems have addressed memory effects. Early applications measured ionic species in the part per billion range. Today reliable part per trillion measurements are common for on-line systems. Current systems are meeting the challenge of EPRI guideline requirements. Today's on-line IC's, with programmed sampling systems, monitor fluid streams throughout a power plant, supplying data that can be trended, stored and retrieved easily. The on-line IC has come of age. Many technical challenges were overcome to achieve today's IC

  3. On-line mixture-based alternative to logistic regression

    Czech Academy of Sciences Publication Activity Database

    Nagy, Ivan; Suzdaleva, Evgenia

    2016-01-01

    Roč. 26, č. 5 (2016), s. 417-437 ISSN 1210-0552 R&D Projects: GA ČR GA15-03564S Institutional support: RVO:67985556 Keywords : on-line modeling * on-line logistic regression * recursive mixture estimation * data dependent pointer Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.394, year: 2016 http://library.utia.cas.cz/separaty/2016/ZS/suzdaleva-0464463.pdf

  4. On-line pre-reduction of Se(VI) by thiourea for selenium speciation by hydride generation

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Jianhua [Department of Chemistry and the MOE Key Laboratory of Analytical Sciences, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005 (China); Wang Qiuquan [Department of Chemistry and the MOE Key Laboratory of Analytical Sciences, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005 (China)]. E-mail: qqwang@xmu.edu.cn; Ma Yuning [Department of Chemistry and the MOE Key Laboratory of Analytical Sciences, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005 (China); Yang Limin [Department of Chemistry and the MOE Key Laboratory of Analytical Sciences, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005 (China); Huang Benli [Department of Chemistry and the MOE Key Laboratory of Analytical Sciences, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005 (China)

    2006-07-15

    In this study, thiourea (TU) was novelly developed as a reduction reagent for on-line pre-reduction of selenium(VI) before conventional hydride generation (HG) by KBH{sub 4}/NaOH-HCl. After TU on-line pre-reduction, the HG efficiency of Se(VI) has been greatly improved and because even higher than that of the same amount of Se(IV) obtained in the conventional HG system. The possible pre-reduction mechanism is discussed. The detection limit (DL) of selenate reaches 10 pg mL{sup -1} when using on-line TU pre-reduction followed by HG atomic fluorescence detection. When TU pre-reduction followed by HG is used as an interface between ion-pair high performance liquid chromatography and atomic fluorescence spectrometry, selenocystine, selenomethionine, selenite and selenate can be measured simultaneously and quantitatively. The DLs of these are 0.06, 0.08, 0.05 and 0.04 ng mL{sup -1}, respectively, and the relative standard deviations of 9 duplicate runs for all the 4 species are less than 5%. Furthermore, it was successfully applied to Se speciation analysis of cultured garlic samples, and validated by determination of total selenium and selenium species in certified reference material NIST 1946.

  5. On-line pre-reduction of Se(VI) by thiourea for selenium speciation by hydride generation

    International Nuclear Information System (INIS)

    Qiu Jianhua; Wang Qiuquan; Ma Yuning; Yang Limin; Huang Benli

    2006-01-01

    In this study, thiourea (TU) was novelly developed as a reduction reagent for on-line pre-reduction of selenium(VI) before conventional hydride generation (HG) by KBH 4 /NaOH-HCl. After TU on-line pre-reduction, the HG efficiency of Se(VI) has been greatly improved and because even higher than that of the same amount of Se(IV) obtained in the conventional HG system. The possible pre-reduction mechanism is discussed. The detection limit (DL) of selenate reaches 10 pg mL -1 when using on-line TU pre-reduction followed by HG atomic fluorescence detection. When TU pre-reduction followed by HG is used as an interface between ion-pair high performance liquid chromatography and atomic fluorescence spectrometry, selenocystine, selenomethionine, selenite and selenate can be measured simultaneously and quantitatively. The DLs of these are 0.06, 0.08, 0.05 and 0.04 ng mL -1 , respectively, and the relative standard deviations of 9 duplicate runs for all the 4 species are less than 5%. Furthermore, it was successfully applied to Se speciation analysis of cultured garlic samples, and validated by determination of total selenium and selenium species in certified reference material NIST 1946

  6. Interfacial reaction using particle-immobilized reagents in a fluidized reactor. Determination of glycerol in biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Shishov, Andrey, E-mail: andrey.shishov.rus@gmail.com [Institute of Chemistry, Saint Petersburg State University, RU–198504 Saint Petersburg (Russian Federation); Zabrodin, Andrey; Moskvin, Leonid [Institute of Chemistry, Saint Petersburg State University, RU–198504 Saint Petersburg (Russian Federation); Andruch, Vasil [Department of Analytical Chemistry, University of P.J. Šafárik, SK-04154 Košice (Slovakia); Bulatov, Andrey [Institute of Chemistry, Saint Petersburg State University, RU–198504 Saint Petersburg (Russian Federation)

    2016-03-31

    A novel fluidized beads strategy for utilization of particle-immobilized reagents in flow analysis was developed in this study. The performance of the suggested strategy was demonstrated by the determination of glycerol in biodiesel. This analytical task was used as a proof-of-concept example. The method is based on on-line extraction of glycerol from biodiesel into aqueous stationary phase of extraction-chromatographic column, followed by elution and spectrophotometric determination in the form of copper glycerate formed in a fluidized reactor of stepwise injection system. The floating of cation exchange resin Dowex{sup ®} 50WX4, saturated with Cu(II) ions in liquid phase, was accomplished by air-bubbling. The linear range was from 100 to 1000 mg kg{sup −1}, and the limit of detection, calculated as 3s of a blank test (n = 5), was found to be 30 mg kg{sup −1}. The method was successfully applied to the analysis of biodiesel and biodiesel-blend (B 20) samples. - Highlights: • Novel fluidized beds strategy for utilization of particle-immobilized reagents. • First application of fluidized beds condition in SWIA. • Novel approach based on interfacial formation of copper glycerate. • Automated method for glycerol determination in biodiesel.

  7. STUDY ON OIL WASTEWATER TREATMENT WITH POLYMERIC REAGENTS

    Directory of Open Access Journals (Sweden)

    RODICA BUCUROIU

    2016-04-01

    Full Text Available Used the polymeric reagents in oil wastewater treatment is an effective method of eliminate hydrocarbons. The present study aims to finding reagents that lead to lowering of extractible (EXT, suspended solids (SS and chemical oxygen demand (COD of industrial wastewater from washing cars in loading ramps petroleum products. For this purpose five reagents were tested, namely: polyamines, cationic polyacrylamides, polydiallydimethyl ammonium chloride (PolyDADMAC, melamine formaldehyde polymer resin and polydicyandiamide polymer resin. Obtaining removal degrees over 80 % justifies using this method in the industrial practice.

  8. The reaction of organocerium reagents with easily enolizable ketones

    International Nuclear Information System (INIS)

    Imamoto, Tsuneo; Kusumoto, Tetsuo; Sugiura, Yasushi; Suzuki, Nobuyo; Takiyama, Nobuyuki

    1985-01-01

    Organocerium (III) reagents were conveniently generated by the reaction of organolithium compounds with anhydrous cerium (III) chloride. The reagents are less basic than organolithiums and Grignard reagents, and they react readily at -78 deg C with easily enolizable ketones such as 2-tetralone to afford addition products in high yields. Cerium (III) enolates were also generated from lithium enolates and cerium (III) chloride. The cerium (III) enolates undergo aldol addition with ketones or sterically crowded aldehyde to give the corresponding β-hydroxy ketones in good to high yields. (author)

  9. Verification test for on-line diagnosis algorithm based on noise analysis

    International Nuclear Information System (INIS)

    Tamaoki, T.; Naito, N.; Tsunoda, T.; Sato, M.; Kameda, A.

    1980-01-01

    An on-line diagnosis algorithm was developed and its verification test was performed using a minicomputer. This algorithm identifies the plant state by analyzing various system noise patterns, such as power spectral densities, coherence functions etc., in three procedure steps. Each obtained noise pattern is examined by using the distances from its reference patterns prepared for various plant states. Then, the plant state is identified by synthesizing each result with an evaluation weight. This weight is determined automatically from the reference noise patterns prior to on-line diagnosis. The test was performed with 50 MW (th) Steam Generator noise data recorded under various controller parameter values. The algorithm performance was evaluated based on a newly devised index. The results obtained with one kind of weight showed the algorithm efficiency under the proper selection of noise patterns. Results for another kind of weight showed the robustness of the algorithm to this selection. (orig.)

  10. OLDASS: On-line data acquisition system at SF cyclotron

    International Nuclear Information System (INIS)

    Omata, Kazuo; Yasue, Masaharu; Hamagaki, Hideki

    1982-01-01

    The on-line data acquisition system in the Institute for Nuclear Study, the University of Tokyo, is composed of 2 systems of Fujitsu mini-computer PFU-400 for data processing at the high energy synchrotron and one system of that computer for low energy cyclotron as terminals, the host computer being M 180 II AD of the same company. This system has been developed to have the features of being the on-line system capable of following the improvement of host computer performance, being capable of developing the on-line programmes of other experimenting groups in parallel with batch jobs or the operation of the on-line system, and capable of developing programmes using FORTRAN. The result of about 220 KB/s was obtained for the data transfer rate between the programmes of the host computer and terminals, and this fulfilled the aimed performance. The terminal system on the low energy side is provided with an ADC interface and a display interface specified particularly in addition to the miniature computer PFU400 and standard I/O devices of the manufacture. The accumulating type graphic display of the I/O devices can be switched to be connected to the host computer, and immediately displays the results transferred to the host computer and analyzed. Hard copy is also available. The above hardware and software are explained. The on-line system insures 80 K bytes of the total memory of 224 K bytes for data area. (Wakatsuki, Y.)

  11. Sport Management Taught On-Line: A Discussion

    Directory of Open Access Journals (Sweden)

    William F. Stier Jr

    2009-01-01

    Full Text Available An introduction to the world of on-line courses (distance education/learning is presented. In addition, the world of on-line learning, as it pertains to sport management, is examined within the framework of (a pedagogy, (b finances,(c assessment, and (d choosing to transition from the traditional classroom to on-line learning. Pertinent points relative to each of the four categories are presented from the literature. In an effort to stimulate thought and discussion to the subject of on-line learning for sport management programs/courses the authors provide their reactions to the literature points by presenting their comments/reactions from a sport management perspective. Sport management professors and administrators are encouraged to critically examine the feasibility of such on-line courses (distance education/learning within their own curricula while maintaining an appropriate framework revolving around sound theoretical instructional strategies, methods as well as appropriate use of instructional tools, including but not limited to, computersand the WWW.

  12. 21 CFR 864.4400 - Enzyme preparations.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Enzyme preparations. 864.4400 Section 864.4400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Specimen Preparation Reagents § 864.4400 Enzyme...

  13. Tetrameric DABCO™-Bromine: an Efficient and Versatile Reagent ...

    African Journals Online (AJOL)

    NJD

    Reagent for Bromination of Various Organic Compounds. Majid M. Heravi,a* ... aDepartment of Chemistry, School of Sciences, Azzahra University, Vanak, Tehran, Iran. bChemistry ... Synthesis of "-bromo ketones and nitriles has also been ...

  14. 21 CFR 866.3470 - Reovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3470 Reovirus... and antisera used in serological tests to identify antibodies to reovirus in serum. The identification...

  15. 21 CFR 866.3870 - Trypanosoma spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3870 Trypanosoma... consist of antigens and antisera used in serological tests to identify antibodies to Trypanosoma spp. in...

  16. 21 CFR 866.3630 - Serratia spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3630 Serratia spp... antigens and antisera used in serological tests to identify Serratia spp. from cultured isolates. The...

  17. 21 CFR 866.3850 - Trichinella spiralis serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3850... devices that consist of antigens and antisera used in serological tests to identify antibodies to...

  18. 21 CFR 866.3680 - Sporothrix schenckii serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3680... devices that consist of antigens and antisera used in serological tests to identify antibodies to...

  19. 21 CFR 866.3660 - Shigella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3660 Shigella spp...), used in serological tests to identify Shigella spp. from cultured isolates. The identification aids in...

  20. 21 CFR 866.3400 - Parainfluenza virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3400 Parainfluenza... that consist of antigens and antisera used in serological tests to identify antibodies to parainfluenza...

  1. 21 CFR 866.3040 - Aspergillus spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3040 Aspergillus... consist of antigens and antisera used in various serological tests to identify antibodies to Aspergillus...

  2. 21 CFR 866.3330 - Influenza virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3330 Influenza... consist of antigens and antisera used in serological tests to identify antibodies to influenza in serum...

  3. 21 CFR 866.3125 - Citrobacter spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3125 Citrobacter... isolates derived from clinical specimens. The identification aids in the diagnosis of disease caused by...

  4. 21 CFR 866.3940 - West Nile virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3940 West Nile... detection aids in the clinical laboratory diagnosis of viral meningitis/encephalitis caused by West Nile...

  5. 21 CFR 866.3740 - Streptococcus spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3740 Streptococcus... derived from clinical specimens. The identification aids in the diagnosis of diseases caused by bacteria...

  6. 21 CFR 866.3065 - Bordetella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3065 Bordetella... serological tests to identify Bordetella spp. from cultured isolates or directly from clinical specimens. The...

  7. 21 CFR 866.3035 - Arizona spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3035 Arizona spp... antisera and antigens used to identify Arizona spp. in cultured isolates derived from clinical specimens...

  8. 21 CFR 866.3380 - Mumps virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3380 Mumps virus... serological tests to identify mumps viruses from tissue culture isolates derived from clinical specimens. The...

  9. Reagent and process for detaching furfural in petroleum products

    Energy Technology Data Exchange (ETDEWEB)

    Orelup, R.B.

    1987-07-14

    A two-component liquid reagent and process is provided for detecting the presence of furfural in petroleum products. The reagent comprises two components which are stored separately from each other and are combined prior to admixture with the petroleum product. The process comprises combining the two separate components of the liquid reagent with each other prior to use, admixing the combined components with a petroleum product containing furfural, shaking the resultant mixture, allowing the mixture to separate and observing a red color characteristic of furfural in the lower layer. Alternately, the process may be carried out by combining the second component of the two-component liquid reagent with the petroleum product, followed by admixture with the first component to obtain two separate layers in which the red color characteristic of furfural is observed in the lower layer.

  10. Method for controlled introduction of reagent into a liquid

    Energy Technology Data Exchange (ETDEWEB)

    Newlove, J.C.; McDougall, L.A.

    1988-11-29

    It is an object of this invention to provide a method for using an article to enhance the production of hydrocarbons from geological reservoirs, more particularly from fractured formations. It is an additional object to devise a method for providing controlled release of a reagent downhole, in a pipeline, or in other oil-containing environments or fluids. Thus, there is provided a method for releasing a treating reagent, such as a wax crystal modifier, scale inhibitor, demulsifier, corrosion inhibitor, antioxidant, and biocide, into a liquid hydrocarbon stream. A plurality of porous, substantially wax-free, plastic particles having a softening point above 60/sup 0/C and being chemically resistant to the hydrocarbon stream are placed in the stream. The said particles contain the treating reagent in their pores, said reagent being insoluble in water and in the particles and being leachable on contact with the stream. The hydrocarbon stream is then flowed past said particles and the reagent is leached from the particle pores. In a specific aspect of this invention, a method is provided for recovering crude oil from an underground formation by means of: depositing the aforementioned particles, containing a suitable reagent, downhole in the oil-producing region of the formation; flowing the oil through the deposited particles, thereby leaching the reagent into the oil; and recovering the oil modified by the presence of an active amount of said reagent. Experiments are described to illustrate ways of producing the polymeric particles of the invention and to illustrate the processes of the invention.

  11. 125I-labeled crosslinking reagent that is hydrophilic, photoactivatable, and cleavable through an azo linkage

    International Nuclear Information System (INIS)

    Denny, J.B.; Blobel, G.

    1984-01-01

    A radioactive crosslinking reagent, N-[4-(p-azido-m-[ 125 I]iodophenylazo)benzoyl]-3-aminopropyl-N'-oxysulfosuccinimide ester, has been synthesized. The reagent is photoactivatable, water-soluble, cleavable through an azo linkage, and labeled with 125 I at the carrier-free specific activity of 2000 Ci/mmol. Any protein derivatized with the reagent is thus converted into an 125 I-labeled photoaffinity probe. Crosslinks are formed following photolysis with 366-nm light, and cleavage by sodium dithionite results in the donation of radioactivity to the distal partner in crosslinked complexes. The newly labeled proteins are then analyzed by gel electrophoresis and autoradiography. The compound was prepared by iodination of N-[4-(p-aminophenylazo)benzoyl]-3-aminopropionic acid using carrier-free Na 125 I and chloramine-T, followed by azide formation and conversion to the water-soluble sulfosuccinimide ester. As a model system, protein A-Sepharose was derivatized with the reagent under subdued light. Each derivatized protein A molecule contained only one crosslinker. The derivatized protein A-Sepharose was then photolyzed in the presence of human serum and subsequently treated with sodium dithionite. Analysis of the serum by gel electrophoresis revealed that 1.1% of the radioactive label originally present on the protein A-Sepharose was transferred to the heavy chain of IgG, which was the most intensely labeled protein in the gel. The next most intensely labeled protein was IgG light chain, which incorporated radioactivity that was lower by a factor of 3.6 than that of the heavy chain. 36 references, 3 figures

  12. On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber

    CERN Document Server

    Bianchi, F; Mathot, S; Baltensperger, U

    2012-01-01

    A new instrument for the on-line determination of ammonia was developed. Since ammonia is a rather sticky compound, sampling losses were minimised with a new sam- pling device where the ammonia was transferred to the liq- uid phase only 5 mm after the inlet tip. The liquid phase was then analyzed by long pathlength absorption spectrophotom- etry using the Berthelot reaction with phenol and hypochlo- rite as reagents. The measurements were made during the CLOUD3 campaign at CERN where the influence of ammo- nia on the nucleation rate was studied. At stable conditions the detection limit reached with this instrument was 35 pptv (air flow rate of 2 l min − 1 , liquid flow rate of 0.3 ml min − 1 ), although occasionally the instrument was affected by back- ground problems. The range of mixing ratios during this campaign was varied from the background contamination ( < 35 pptv) up to around 2 ppbv. The measured ammonia concentration was correlated with the rate of ammonia in- jected into the chamber, but wi...

  13. Initiating Events Modeling for On-Line Risk Monitoring Application

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.

    1998-01-01

    In order to make on-line risk monitoring application of Probabilistic Risk Assessment more complete and realistic, a special attention need to be dedicated to initiating events modeling. Two different issues are of special importance: one is how to model initiating events frequency according to current plant configuration (equipment alignment and out of service status) and operating condition (weather and various activities), and the second is how to preserve dependencies between initiating events model and rest of PRA model. First, the paper will discuss how initiating events can be treated in on-line risk monitoring application. Second, practical example of initiating events modeling in EPRI's Equipment Out of Service on-line monitoring tool will be presented. Gains from application and possible improvements will be discussed in conclusion. (author)

  14. Strengthening weak ties through on-line gaming

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana Virginia; Kirchner, Kathrin

    On-line gaming became widespread in the last couple of years. The aim of the research presented in the paper is to figure out to what extent does game playing helps to strengthen weak ties and what additional factors influence this process. The approach is rather exploratory – some factors...... are grounded in theory, some are new. These factors are age, gender, place of origin, number of their Facebook connections (friends in Facebook terminology), the amount of time they are on Facebook, the amount of time they keep the Facebook site open, the amount of time they play on-line games, and the reasons...... for starting to play on-line games. Regarding the latter, we chose to focus only on escapist reasons....

  15. Thermographic Sensing For On-Line Industrial Control

    Science.gov (United States)

    Holmsten, Dag

    1986-10-01

    It is today's emergence of thermoelectrically cooled, highly accurate infrared linescanners and imaging systems that has definitely made on-line Infraread Thermography (IRT) possible. Specifically designed for continuous use, these scanners are equipped with dedicated software capable of monitoring and controlling highly complex thermodynamic situations. This paper will outline some possible implications of using IRT on-line by describing some uses of this technology in the steel-making (hot rolling) and automotive industries (machine-vision). A warning is also expressed that IRT technology not originally designed for automated applications e.g. high resolution, imaging systems, should not be directly applied to an on-line measurement situation without having its measurement resolution, accuracy and especially its repeatability, reliably proven. Some suitable testing procedures are briefly outlined at the end of the paper.

  16. An on-line monitoring system for navigation equipment

    Science.gov (United States)

    Wang, Bo; Yang, Ping; Liu, Jing; Yang, Zhengbo; Liang, Fei

    2017-10-01

    Civil air navigation equipment is the most important infrastructure of Civil Aviation, which is closely related to flight safety. In addition to regular flight inspection, navigation equipment's patrol measuring, maintenance measuring, running measuring under special weather conditions are the important means of ensuring aviation flight safety. According to the safety maintenance requirements of Civil Aviation Air Traffic Control navigation equipment, this paper developed one on-line monitoring system with independent intellectual property rights for navigation equipment, the system breakthroughs the key technologies of measuring navigation equipment on-line including Instrument Landing System (ILS) and VHF Omni-directional Range (VOR), which also meets the requirements of navigation equipment ground measurement set by the ICAO DOC 8071, it provides technical means of the ground on-line measurement for navigation equipment, improves the safety of navigation equipment operation, and reduces the impact of measuring navigation equipment on airport operation.

  17. On-line calculation of 3-D power distribution

    International Nuclear Information System (INIS)

    Park, Y. H.; In, W. K.; Park, J. R.; Lee, C. C.; Auh, G. S.

    1996-01-01

    The 3-D power distribution synthesis scheme was implemented in Totally Integrated Core Operation Monitoring System (TICOMS), which is under development as the next generation core monitoring system. The on-line 3-D core power distribution obtained from the measured fixed incore detector readings is used to construct the hot pin power as well as the core average axial power distribution. The core average axial power distribution and the hot pin power of TICOMS were compared with those of the current digital on-line core monitoring system, COLSS, which construct the core average axial power distribution and the pseudo hot pin power. The comparison shows that TICOMS results in the slightly more accurate core average axial power distribution and the less conservative hot pin power. Therefore, these results increased the core operating margins. In addition, the on-line 3-D power distribution is expected to be very useful for the core operation in the future

  18. Approaches for on-line coupling of extraction and chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Hyoetylaeinen, Tuulia; Riekkola, Marja-Liisa [Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki (Finland)

    2004-04-01

    This review provides an overview of the approaches available in order to perform on-line coupling of various extraction techniques with liquid and gas chromatography, for the analysis of semivolatile and nonvolatile analytes in liquid and solid samples. The main focus is on the instrumental set-up of these techniques. Selected real applications are described by way of illustration. The extraction methods suitable for on-line coupling covered in this review are: liquid-liquid extraction, solid-phase extraction, membrane-based techniques, pressurised liquid extraction, supercritical fluid extraction, and microwave- and sonication-assisted extractions. The following systems are not covered in this review: on-line coupled solid-phase extraction-liquid chromatography, purge-and-trap-GC, and membrane extraction with a sorbent interface-GC. (orig.)

  19. UNISOR on-line nuclear orientation facility (UNISOR/NOF)

    International Nuclear Information System (INIS)

    Girit, I.C.; Alton, G.D.; Bingham, C.R.; Carter, H.K.; Simpson, M.L.; Cole, J.D.; Croft, W.L.; Hamilton, J.H.; Jones, E.F.; Gore, P.M.; Kormicki, J.; Xie, H.; Kern, B.D.; Krane, K.S.; Xu, Y.S.; Mantica, P.F. Jr.; Zimmermann, B.E.; Nettles, W.G.; Zganjar, E.F.; Kortelahti, M.O.; Newbolt, W.B.

    1988-01-01

    The UNISOR on-line nuclear orientation facility (UNISOR/NOF) consists of a 3 He- 4 He dilution refrigerator on line to the isotope separator. Nuclei are implanted directly into a target foil which is soldered to the bottom accessed cold finger of the refrigerator. A 1.5 T superconducting magnet polarizes the ferromagnetic target foils and determines the axis of symmetry. Up to eight gamma detectors can be positioned around the refrigerator, each 9 cm from the target. A unique feature of this system is that the k=4 term in the directional distribution function can be directly and unambigously deduced so that a single solution for the mixing ratio can be found. The first on-line experiment at this facility reported here was a study of the decay of the 191 Hg and 193 Hg isotopes. (orig.)

  20. Evaluation of novel derivatisation reagents for the analysis of oxysterols

    Energy Technology Data Exchange (ETDEWEB)

    Crick, Peter J., E-mail: p.j.crick@swansea.ac.uk [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Aponte, Jennifer; Bentley, T. William [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Matthews, Ian [College of Engineering, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Wang, Yuqin [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Griffiths, William J., E-mail: w.j.griffiths@swansea.ac.uk [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom)

    2014-04-11

    Graphical abstract: - Highlights: • New derivatisation reagents for LC–MS analysis of oxysterols. • New reagents based on Girard P give high ion-currents and informative LC–MS{sup n} spectra. • Permanent charge is vital for efficient MS{sup n} fragmentation. • New reagents offer greater scope for incorporation of isotope labels. - Abstract: Oxysterols are oxidised forms of cholesterol that are intermediates in the synthesis of bile acids and steroid hormones. They are also ligands to nuclear and G protein-coupled receptors. Analysis of oxysterols in biological systems is challenging due to their low abundance coupled with their lack of a strong chromophore and poor ionisation characteristics in mass spectrometry (MS). We have previously used enzyme-assisted derivatisation for sterol analysis (EADSA) to identify and quantitate oxysterols in biological samples. This technique relies on tagging sterols with the Girard P reagent to introduce a charged quaternary ammonium group. Here, we have compared several modified Girard-like reagents and show that the permanent charge is vital for efficient MS{sup n} fragmentation. However, we find that the reagent can be extended to include sites for potential stable isotope labels without a loss of performance.

  1. Making the most of on-line recruiting.

    Science.gov (United States)

    Cappelli, P

    2001-03-01

    Ninety percent of large U.S. companies are already recruiting via the Internet. By simply logging on to the Web, company recruiters can locate vast numbers of qualified candidates for jobs at every level, screen them in minutes, and contact the most promising ones immediately. The payoffs can be enormous: it costs substantially less to hire someone on-line, and the time saved is equally great. In this article, Peter Cappelli examines some of the emerging service providers and technologies--matchmakers, job boards, hiring management systems software, and applicant-screening mechanisms that test skills and record interests. He also looks at some of the strategies companies are adopting as they enter on-line labor markets. Recruiting needs to be refashioned to resemble marketing, he stresses. Accordingly, smart companies are designing Web pages, and even product ads, with potential recruits in mind. They're giving line managers authority to hire so that candidates in cyberspace aren't lost. They're building internal on-line job networks to retain talent. Integrating recruiting efforts with overall marketing campaigns, especially through coordination and identification with the company's brand, is the most important thing companies can do to ensure success in on-line hiring. Along the way, Cappelli sounds two cautionary notes. First, a human touch, not electronic contact, is vital in the last steps of a successful hiring process. Second, companies must make sure that on-line testing and hiring criteria do not discriminate against women, disabled people, workers over 40, or members of minority groups. When competition for talent is fierce, companies that master the art and science of on-line recruiting will be the ones that attract and keep the best people.

  2. Quality control of radioimmunoassay reagents for T4

    International Nuclear Information System (INIS)

    Wayan Radiatning, S.

    1987-01-01

    Quality control of radioimmunoassay reagents for T4. A program of quality control testing has been carried out for 125 I-T4, T4 standards and T4 antisera. 125 I-labelled T4 has been tested for its specific activity, radiochemical purity using a Sephadex G-25 column, immunological activity, based on the immunological reaction between labelled antigen and excess T4 antibody, and non-specific binding. The useful shelf-life of the labelled compound was determined by monitoring the decrease in radiochemical purity and immunological activity, and the increase in non-specific binding. T4 standards were calibrated by means of T4 RIA kit manufactured by DPC (Diagnostic Products Corporation). A test on parallelism was also performed using hyperthyroid sera. T4 antisera were evaluated with respect to titre, avidity and specifity. The test results on 125 I-T4 show a specific activity varying between 1830-2020 uCi/ug, a radiochemical purity above 90%, an immunological more than 80% and a non-specific binding of less than 5%. The standard curve for T4 was found to coincide well with the standard curve of the DPC kit and parallel with the curve for hyperthyroid sera. The titre of T4 antisera obtained was 1:300, the avidity was about 4.8 x 10 7 and the cross-reaction for T3 was 1.6%. It can be concluded from the experimental results, that the 125 I-T4, T4 standards and T4 antisera prepared meet the requirements for the manufacture of T4 kits. (author). 5 refs.; 14 figs

  3. The User-friendly On-Line Diffusion Chamber

    CERN Document Server

    Aviles Acosta, Jaime

    2015-01-01

    The On-Line Diffusion Chamber is a stand-alone apparatus built to carry out short-live radiotracer diffusion studies. The availability of the on-demand production of isotopes in the ISOLDE facility, and the design of the apparatus to streamline the implantation process, annealing treatment, ion gun ablation with a tape transport system, and radiation intensity measurement with a Ge gamma detector all in the same apparatus, gives the On-Line Diffusion Chamber a unique ability to studies with short-lived radioisotopes or isomer states that are not possible in any other facility in the world.

  4. The rationalization of desulfurization by on-line analysis

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Y; Kohmura, S; Taketomi, H; Matsumura, S; Sasaki, Y

    1986-01-01

    Nippon Kokan uses the Takahax and Sulfiban processes for the desulfurization of coke oven gas. The authors outline the Sulfiban Process and describe a recently developed system for the on-line determination of H/sub 2/S in coke oven gas, and of CO/sub 2/ and monoethanolamine (MEA) in the wash oil. This new on-line analysis system has proved effective in rationalizing the Sulfiban Process via lower MEA production costs and decreased power consumption. The introduction of a computerized control system is now being studied. 7 figs., 4 tabs.

  5. 5th Computer Science On-line Conference

    CERN Document Server

    Senkerik, Roman; Oplatkova, Zuzana; Silhavy, Petr; Prokopova, Zdenka

    2016-01-01

    This volume is based on the research papers presented in the 5th Computer Science On-line Conference. The volume Artificial Intelligence Perspectives in Intelligent Systems presents modern trends and methods to real-world problems, and in particular, exploratory research that describes novel approaches in the field of artificial intelligence. New algorithms in a variety of fields are also presented. The Computer Science On-line Conference (CSOC 2016) is intended to provide an international forum for discussions on the latest research results in all areas related to Computer Science. The addressed topics are the theoretical aspects and applications of Computer Science, Artificial Intelligences, Cybernetics, Automation Control Theory and Software Engineering.

  6. Comparison of Current On-line Payment Technologies

    OpenAIRE

    Mandadi, Ravi

    2006-01-01

    The purpose of this thesis work was to make a survey of current on-line payment technologies and find out which are they and how do they work? Compare and analyze them from a security point of view, as well as a usability point of view. What is good? What is bad? What is lacking? To achieve this purpose, an overview of the current on-line payment technologies was acquired through academic books and papers, Internet sites, magazines. Basic cryptographic and security related techniques were stu...

  7. An on-line adaptive core monitoring system

    International Nuclear Information System (INIS)

    Verspeek, J.A.; Bruggink, J.C.; Karuza, J.

    1997-01-01

    An on-line core monitoring system has been in operation for three years in the Dodewaard Nuclear Power Plant. The core monitor uses the on-line measured reactor data as an input for a power distribution calculation. The measurements are frequently performed. The system is used for monitoring as well as for predicting purposes. The limiting thermal hydraulic parameters are monitored as well as the pellet-clad interaction limits. The data are added to a history file used for cycle burn-up calculations and trending of parameters. The reactor states are presented through a convenient graphical user interface. (authors)

  8. On-Line Generation of 3D-Waves

    DEFF Research Database (Denmark)

    Frigaard, Peter

    1992-01-01

    The paper describes the technique of filtering white noise for on-line generation of 3D-waves on a small computer in the laboratory. The wave generation package is implemented and tested in the 3D-wave basin at the University of Aalborg.......The paper describes the technique of filtering white noise for on-line generation of 3D-waves on a small computer in the laboratory. The wave generation package is implemented and tested in the 3D-wave basin at the University of Aalborg....

  9. Reverse flow injection spectrophotometric determination of ciprofloxacin in pharmaceuticals using iron from soil as a green reagent

    Science.gov (United States)

    Palamy, Sysay; Ruengsitagoon, Wirat

    2018-02-01

    A novel reverse flow injection spectrophotometric method for the determination of ciprofloxacin was successfully combined with the on-line introduction of an iron solution extracted from soil as green reagent. The assay was optimized by a univariate method to select the optimum conditions for the highest absorbance and highest stability of the complex. Beer-Lambert's law (λmax = 440 nm) is obeyed in the range 0.5-50 μg mL- 1 with a correlation coefficient (r2) of 0.9976 and 0.9996 using soil as green reagent from Khon Kaen, Thailand and Vientiane, Laos, respectively. The average percentage recoveries were in the range of 98.55-102.14% and the precision was in the range of 0.80-1.73%. The limit of detection and the limit of quantitation were 0.20 and 0.69 μg mL- 1, respectively, with a sampling rate of over 46 samples h- 1. The method was successfully applied to the determination of ciprofloxacin in commercial pharmaceutical formulations. The results were in good agreement with those obtained by the reference HPLC method using a t-test at 95% of confidence level for comparison. This method is suitable for laboratories looking for alternative analytical methods using green reagents.

  10. Optimization of antibody immobilization for on-line or off-line immunoaffinity chromatography

    DEFF Research Database (Denmark)

    Beyer, Natascha Helena; Schou, Christian; Højrup, Peter

    2009-01-01

    -POROS. Protein G-based matrices are very stable showing essentially no decline in performance after 50 application-wash-elution-reequilibration cycles and being easily prepared within 2-3 h of working time with a typical antibody coupling yield of above 80%. In off-line applications where constant flow....... A systematic study was conducted to determine the most versatile antibody immobilization method for use in on-line and off-line IA chromatography applications using commonly accessible immobilization methods. Four chemistries were examined using polyclonal and monoclonal antibodies and antibody fragments. We...

  11. FI/SI on-line solvent extraction/back extraction preconcentration coupled to direct injection nebulization inductively coupled plasma mass spectrometry for determination of copper and lead

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    An automated sequential injection on-line preconcentration procedure for determination of trace levels of copper and lead via solvent extraction/back extraction coupled to ICP-MS is described. In citrate buffer of pH 3, neutral complexes between the analytes and the chelating reagent, ammonium...... loop, the content of which is subsequently introduced into the ICP-MS, via a direct injection high efficiency nebulizer (DIHEN), for quantification. Enrichment factors of 29.6 (Cu) and 23.3 (Pb), detection limits of 17 ng/l (Cu) and 11 ng/l (Pb), along with a sampling frequency of 13 s/h were obtained...

  12. Integrated sensor array for on-line monitoring micro bioreactors

    NARCIS (Netherlands)

    Krommenhoek, E.E.

    2007-01-01

    The “Fed��?batch on a chip��?��?project, which was carried out in close cooperation with the Technical University of Delft, aims to miniaturize and parallelize micro bioreactors suitable for on-line screening of micro-organisms. This thesis describes an electrochemical sensor array which has been

  13. On-Line Pesticide Training with Narrated Powerpoint Presentations

    Science.gov (United States)

    Johnson, Steven B.

    2015-01-01

    UMaine Cooperative Extension is the primary educational delivery organization for pesticide recertification credits in Maine. Shrinking budgets and staff numbers are making traditional face-to-face delivery increasingly difficult to maintain. To address this issue, on-line pesticide applicator recertification training credits were developed. The…

  14. Personality Interactions and Scaffolding in On-Line Discussions

    Science.gov (United States)

    Nussbaum, E. Michael; Hartley, Kendall; Sinatra, Gale M.; Reynolds, Ralph E.; Bendixen, Lisa D.

    2004-01-01

    The potential of on-line discussions to prompt greater reflection of course material is often stymied by a tendency of students to agree with one another rather than to formulate counter-arguments. This article describes an experiment using note starters and elaborated cases to encourage counter-argumentation and examines interactions with…

  15. A new electrostatic on-line collection-system

    International Nuclear Information System (INIS)

    Dufour, J.P.; Del Moral, R.; Fleury, A.; Hubert, F.; Llabador, Y.; Mauhourat, M.B.; Bimbot, R.; Gardes, D.; Rivet, M.F.

    1981-01-01

    The working conditions of a new on-line electrostatic collection system are presented. The main characteristics are high efficiency (reaching 20%) and short delay time (down to the millisecond). The salient features of specific devices for measurements of absolute cross sections, recoil range distributions and angular distributions are given. (orig.)

  16. Specialization processes in on-line unsupervised learning

    NARCIS (Netherlands)

    Biehl, M.; Freking, A.; Reents, G.; Schlösser, E.

    1998-01-01

    From the recent analysis of supervised learning by on-line gradient descent in multilayered neural networks it is known that the necessary process of student specialization can be delayed significantly. We demonstrate that this phenomenon also occurs in various models of unsupervised learning. A

  17. A simulation of the SDC on-line processing farm

    International Nuclear Information System (INIS)

    Wang, C.; Chen, Y.; Dorenbosch, J.; Lee, J.; Sayle, R.

    1993-10-01

    In the Solenoidal Detector Collaboration (SDC) data acquisition system (DAQ), an enormous amount of data flows into a processor farm for extraction of interesting physics events. To design an efficient on-line filter, the operations in the farm must be carefully modeled. The authors present a simulation model developed at the Superconducting Super Collider Laboratory which efficiently allocates physics events to the farm

  18. On-Line Synthesis and Analysis by Mass Spectrometry

    Science.gov (United States)

    Bain, Ryan M.; Pulliam, Christopher J.; Raab, Shannon A.; Cooks, R. Graham

    2015-01-01

    In this laboratory experiment, students learn how to use ESI to accelerate chemical synthesis and to couple it with on-line mass spectrometry for structural analysis. The Hantzsch synthesis of symmetric 1,4-dihydropyridines is a classic example of a one-pot reaction in which multiple intermediates can serve to indicate the progress of the reaction…

  19. An optimal algorithm for preemptive on-line scheduling

    NARCIS (Netherlands)

    Chen, B.; Vliet, van A.; Woeginger, G.J.

    1995-01-01

    We investigate the problem of on-line scheduling jobs on m identical parallel machines where preemption is allowed. The goal is to minimize the makespan. We derive an approximation algorithm with worst-case guarantee mm/(mm - (m - 1)m) for every m 2, which increasingly tends to e/(e - 1) ˜ 1.58 as m

  20. Comparison between constant methanol feed and on-line ...

    African Journals Online (AJOL)

    Two methanol feeding methods, namely constant methanol feed and on-line monitoring feed control by methanol sensor were investigated to improve the production of recombinant human growth hormone (rhGH) in high cell density cultivation of Pichia pastoris KM71 in 2 L bioreactor. The yeast utilized glycerol as a carbon ...

  1. Children's On-Line Processing of Scrambling in Japanese

    Science.gov (United States)

    Suzuki, Takaaki

    2013-01-01

    This study investigates the on-line processing of scrambled sentences in Japanese by preschool children and adults using a combination of self-paced listening and speeded picture selection tasks. The effects of a filler-gap dependency, reversibility, and case markers were examined. The results show that both children and adults had difficulty in…

  2. AAEC INIS - a large, new, on-line information source

    International Nuclear Information System (INIS)

    Rugg, T.J.; Wong, S.C.

    1984-01-01

    The Australian Atomic Energy Commission's INIS database is available for on-line searching by non-AAEC personnel from all parts of Australia. An introduction to the International Nuclear Information System is followed by information on searching AAEC INIS, AAEC INIS retrieval software and accessing AAEC INIS

  3. ORION-the Omega Remote Interactive On-line System

    CERN Document Server

    Russell, R D; Levratt, B; Lipps, H; Sparrman, P

    1974-01-01

    ORION is a system which permits the manipulation of files, records and characters, remote job submittal and retrieval of output files including the direct loading of remote on-line computers. The system uses the computer hardware of the OMEGA project at CERN and is designed to assist researchers in development and debugging of their programs. (10 refs).

  4. ORION - the OMEGA Remote Interactive On-line System

    CERN Document Server

    Russell, R D; Krieger, M

    1973-01-01

    ORION is a system which permits the manipulation of files, records and characters, remote job submittal and retrieval of output files including the direct loading of remote on-line computers. The system uses the computer hardware of the OMEGA project at CERN, and is designed to assist researchers in development and debugging of their programs.

  5. Booth Library On-Line Circulation System (BLOC

    Directory of Open Access Journals (Sweden)

    Paladugu V. Rao

    1971-06-01

    Full Text Available An on-line circulation system developed at a relatively small university library demonstrates that academic libraries with limited funds can develop automated systems utilizing parent institution's computer facilities in a time-sharing mode. In operation since September 1968, using an IBM 360/50 computer and associated peripheral equipment, it provides control over all stack books.

  6. On-line learning from clustered input examples

    NARCIS (Netherlands)

    Riegler, Peter; Biehl, Michael; Solla, Sara A.; Marangi, Carmela; Marinaro, Maria; Tagliaferri, Roberto

    1996-01-01

    We analyse on-line learning of a linearly separable rule with a simple perceptron. Example inputs are taken from two overlapping clusters of data and the rule is defined through a teacher vector which is in general not aligned with the connection line of the cluster centers. We find that the Hebb

  7. Investigating on-line pornography at the University of Johannesburg

    Directory of Open Access Journals (Sweden)

    P. Laughton

    2008-01-01

    Full Text Available The on-line user of today has access to a vast collection of information resources. In addition, the developments in Internet and Web technologies have made it even easier for surfers to anonymously get access to on-line pornography. The purpose of this research was to investigate the extent to which access to on-line pornography at the University of Johannesburg can be managed. For the empirical part of this research 1037 questionnaires were proportionally distributed to and completed by students on all five campuses of the university. The questionnaire consisted of four sections: biographical information; university computer facility usage; university acceptable use policy; and personal experience with university computer facilities. The gender distribution for the sample was almost even, with a total of 49,4% male participants and 50,6% female, with the largest grouping of respondents (61,6% aged between 19 years and 21 years. Of the respondents, 36,7% indicated that exposure to unsolicited pornography did not bother them. When asked to what extent students should have access to pornography, 60,5% stated 'None' while 32,6% believed that 'Restricted' access should be granted for research purposes and 6,9% believed that students should be granted 'Total' access to pornography. Results from the research will be used to manage access to on-line resources at the University of Johannesburg better.

  8. On-line sample treatment - Capillary gas chromatography

    NARCIS (Netherlands)

    Goosens, EC; de Jong, D; de Jong, GJ; Brinkman, UAT

    Sample pretreatment is often the bottleneck of a trace level analytical procedure. In order to increase performance, increasing attention is therefore being devoted to combining sample pretreatment on-line with the separation technique that has to be used. In the present review, a variety of

  9. A new electrostatic on-line collection-system

    International Nuclear Information System (INIS)

    Dufour, J.P.; Del Moral, R.; Fleury, A.

    1981-06-01

    The working conditions of a new on-line electrostatic collection system are presented. The main charactersitics are high efficiency (reaching 20%) and short delay time (down to the millisecond). The salient features of specific devices for measurements of absolute cross sections, recoil range distributions and angular distributions are given

  10. Summary remarks and prospects for on-line nuclear orientation

    International Nuclear Information System (INIS)

    Krane, K.S.; Hamilton, J.H.

    1984-01-01

    This paper reviews the use of on-line nuclear orientations as a method for determining hyperfine structure. Historical developments and future prospects for the technique are presented. The role that this technique can play in nuclear spectroscopy and the study of nuclei far from the beta stability are outlined

  11. WMI2, the Student's On-Line Symbolic Calculator

    Science.gov (United States)

    Kovacs, Zoltan

    2011-01-01

    Student activities focused on discovering mathematics play an important role in the teaching and learning process. WebMathematics Interactive (WMI2) was developed to offer a fast and user-friendly on-line web interface to enhance the quality of both theoretical and applied mathematics courses. For the teacher, in the classroom, it provides…

  12. ADAPTIVE CONTEXT PROCESSING IN ON-LINE HANDWRITTEN CHARACTER RECOGNITION

    NARCIS (Netherlands)

    Iwayama, N.; Ishigaki, K.

    2004-01-01

    We propose a new approach to context processing in on-line handwritten character recognition (OLCR). Based on the observation that writers often repeat the strings that they input, we take the approach of adaptive context processing. (ACP). In ACP, the strings input by a writer are automatically

  13. Microcomputers as on-line catalogs in special libraries.

    Science.gov (United States)

    Faust, J B

    1986-01-01

    This article discusses the rationale for the conversion of a card catalog to an on-line system in a special library owning approximately 4000 titles. Equipment, software, and procedures are described. Pros and cons of the use of a microcomputer for such a project, as well as costs and personnel needs, are outlined.

  14. Efficient and secure comparison for on-line auctions

    NARCIS (Netherlands)

    Damgard, Ivan; Geisler, M.; Kroigaard, M.; Pieprzyk, J.; Ghodosi, H.; Dawson, E.

    2007-01-01

    We propose a protocol for secure comparison of integers based on homomorphic encryption. We also propose a homomorphic encryption scheme that can be used in our protocol and makes it more efficient than previous solutions. Our protocol is well-suited for application in on-line auctions, both with

  15. The on-line asymmetric traveling salesman problem

    NARCIS (Netherlands)

    Ausiello, G.; Bonifaci, V.; Laura, L.

    2008-01-01

    We consider two on-line versions of the asymmetric traveling salesman problem with triangle inequality. For the homing version, in which the salesman is required to return in the city where it started from, we give a -competitive algorithm and prove that this is best possible. For the nomadic

  16. Facing regulatory challenges of on-line hemodiafiltration.

    Science.gov (United States)

    Kümmerle, Wolfgang

    2011-01-01

    On-line hemodiafiltration (on-line HDF) is the result of a vision that triggered multifarious changes in very different areas. Driven by the idea to offer better medical treatment for renal patients, technological innovations were developed and established that also constituted new challenges in the field of regulatory affairs. The existing regulations predominantly addressed the quality and safety of those products needed to perform dialysis treatment which were supplied by industrial manufacturers. However, the complexity of treatment system required for the provision of on-line fluids demanded a holistic approach encompassing all components involved. Hence, focus was placed not only on single products, but much more on their interfacing, and the clinical infrastructure, in particular, had to undergo substantial changes. The overall understanding of the interaction between such factors, quite different in their nature, was crucial to overcome the arising regulatory obstacles. This essay describes the evolution of the on-line HDF procedure from the regulatory point of view. A simplified diagram demonstrates the path taken from the former regulatory understanding to the realization of necessary changes. That achievement was only possible through 'management of preview' and consequent promotion of technical and medical innovations as well as regulatory re-evaluations. Copyright © 2011 S. Karger AG, Basel.

  17. Project development and commercialization of on-line analysis systems

    International Nuclear Information System (INIS)

    Watt, J.S.

    1997-01-01

    A project team first in the Australian Atomic Energy Commission (AAEC) and since 1982 in CSIRO has developed many on-line analysis systems for the mineral and energy industries. The development of these projects has followed a common pattern of laboratory R and D, field trials, commercialisation and technology transfer. This successful pattern is illustrated using examples of the development of systems for the on-line analysis of mineral slurries, for determination of the ash content of coal on conveyors, and for determination of the flow rates of oil, water and gas in pipelines. The first two systems are licensed to Australian companies, Amdel Ltd and Mineral Control Instrumentation Ltd. Both systems are used by industry worldwide, and are the market leaders for radioisotope gauges in their application field. The third system, the multiphase flow meter, was licensed in 1997 to Kvaerner FSSL Ltd of Aberdeen. This meter has even greater potential than the other two systems for economic benefit from its used and for numbers of installations. The on-line analysis systems have been developed to increase the productivity of the Australian mineral and energy industries, and to provide economic benefit to Australia. The economic benefit sought is predominantly improved process control based on use of the instrument, rather than from its sale. Sales of instruments are significant, however, with about A$80 million from the analysis systems and their derivatives since the 1970s. Some of the issues associated with the development of the on-line analysis system are outlined

  18. Reagent conditions of the flotation of copper, copper - molybdenum and copper -zinc ores in foreing countries

    International Nuclear Information System (INIS)

    Nevaeva, L.M.

    1983-01-01

    Reagents-collectors and frothers, used abroad in reagent regimes of flotation of copper, copper-molybdenum and copper zinc ores, have been considered. Xanthogenates, aerofloats, xanthogenformiates, thionocarbamates are mainly used as reagents-collectors. Methylizobutylcarbinol and Daufros are used as reagents-frothers

  19. 21 CFR 866.3720 - Streptococcus spp. exo-enzyme reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Streptococcus spp. exo-enzyme reagents. 866.3720... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3720 Streptococcus spp. exo-enzyme reagents. (a) Identification. Streptococcus spp. exoenzyme reagents are devices used...

  20. IOOS Data Portals and Uniform On-line Browse Capabilities

    Science.gov (United States)

    Howard, M.; Currier, R. D.; Kobara, S.; Gayanilo, F.

    2015-12-01

    The Gulf of Mexico Coastal Ocean Observing System Regional Association (GCOOS-RA) is one of eleven Regional Associations organized under the NOAA-led U.S. Integrated Ocean Observing System (IOOS) Program Office. Each of the RAs operate standards-based regional data portals designed to aggregate near real-time and historical observed data and modeled outputs from distributed providers and to offer these and derived products in standardized ways to a diverse set of users. The RA's portals are based on the IOOS Data and Communications Plan which describes the functional elements needed for an interoperable system. One of these elements is called "Uniform On-line Browse" which is an informational service designed primarily to visualize the inventory of a portal. An on-line browse service supports the end user's need to discover what parameters are available, to learn the spatial and temporal extend of the holdings, and to examine the character of the data (e.g, variability, gappiness, etc). These pieces of information help the end user decide if the data are fit for his/her purpose and to construct valid data requests. Note that on-line browse is a distinctly different activity than data analysis because it seeks to yield knowledge about the inventory and not about what the data mean. "Uniform" on-line browse is a service that takes advantage of the standardization of the data portal's data access points. Most portals represent station locations on a map. This is a view of the data inventory but these plots are rarely generated by pulling data through the standards-based services offered to the end users but through methods only available to the portal programmers. This work will present results of Uniform On-line browse tools developed within GCOOS-RA and their applicability to other RA portals.

  1. An oral Mycobacterium bovis BCG vaccine for wildlife produced in the absence of animal-derived reagents.

    Science.gov (United States)

    Cross, Martin L; Lambeth, Matthew R; Aldwell, Frank E

    2009-09-01

    Cultures of Mycobacterium bovis BCG, comprising predominantly single-cell bacilli, were prepared in broth without animal-derived reagents. When formulated into a vegetable-derived lipid matrix, the vaccine was stable in vitro and was immunogenic in vivo upon feeding it to mice. This formulation could be useful for oral vaccination of wildlife against tuberculosis, where concern over transmissible prions may preclude the field use of vaccines containing animal products.

  2. Treatment of laundrette wastewater using Starbon and Fenton's reagent.

    Science.gov (United States)

    Tony, Maha A; Parker, Helen L; Clark, James H

    2016-09-18

    The use of grey water for a variety of purposes is gaining increased popularity as a means of preserving scarce freshwater resources. In this work, catalytic oxidation over Fenton's reagent and adsorption techniques using Starbon (mesoporous material derived from polysaccharides) has been applied. These novel techniques are used as an alternative to already studied treatments of grey water such as filtration and/or biological processes. In this study, grey water, collected from a commercial laundrette, has been used. Treatment efficiency was determined by changes in the chemical oxygen demand (COD) of the grey water. Experiments using Fenton's reagent at optimum conditions of Fe(3+) = 40 mg L(-1); H2O2 = 400 mg L(-1) and pH 3 were very successful, resulting in a 95% COD removal after 15 min. Treatment with Starbon adsorption was also effective, reaching up to 81% COD removal at pH 3 within 1 h. The combined treatment with Fenton's reagent and Starbon resulted in a 93% COD removal at a significantly reduced concentration of Fenton's reagent compared to the treatment with solo Fenton's reagent. This lower chemical dose has the advantage of reducing costs and lowering sludge generation.

  3. On-line measurement and control in sustainable mineral processing and energy production

    International Nuclear Information System (INIS)

    Sowerby, B.D.

    2002-01-01

    Sustainable development can be defined as development that 'meets the needs of the present without compromising the ability of future generations to meet their own needs' (WCED, 1987). A sustainable minerals and energy industry will need to achieve a number of related objectives including greater energy efficiency, improved utilisation of ore deposits, improved utilisation of existing plant, improved product quality, reduction of waste material, reduction of pollution levels and improved safety margins. These objectives all relate in varying degrees to the triple bottom line of economic, social and environmental benefits. One critical component in achieving these objectives is to develop and apply improved control systems across the full range of industry applications from mining to processing and utilisation. However process control relies heavily on the availability of suitable on-line process instrumentation to provide the data and feedback necessary for its implementation. There is a lot of truth in the saying 'if you can't measure it you can't control it'. In the past measurement was achieved by manual sampling followed by sample preparation (such as drying, mixing, crushing and dividing) and off-line laboratory analysis. However this procedure is often subject to significant sampling errors and, most importantly, the measurements are too slow for control purposes. By contrast, on-line analysis can provide rapid and accurate measurement in real time thus opening up new possibilities for improved process control. As a result, there has been a rapid increase in the industrial application of on-line analysis instrumentation over the past few decades. The main purpose of this paper is to briefly review some past Australian developments of on-line analysis systems in the mineral and coal industries and to discuss present developments and future trends

  4. On-line analysis of water contamination by organic compounds; On-line-Analytik der Wasserverschmutzung durch organische Substanzen

    Energy Technology Data Exchange (ETDEWEB)

    Wagt, R. van der; Vos, F. de [Skalar Analytical (Netherlands); Babichenko, S.; Poryvkina, L. [Institute of Ecology, Tallinn (Estonia)

    1999-08-01

    In many environmental applications decomposing the mixture of substances in the water into its various chemical ingredients, for subsequent analysis, is a very complicated task. The most productive approach to on-line diagnosis is to treat the object as an integral spectroscopic sample, characterized by certain specific Spectral Fluorescent Signatures (SFS). The SFS are recorded as a matrix of fluorescent intensity of organic compounds in water, in co-ordinates of excitation and emission spectra, providing a three-dimensional spectrum. Spectral windows of SFS are defined by fluorescent characteristics of basic groups of organic substances in the water sample. The novel Skalar Fluo Imager, based on this principle, is intended for the analysis of organic compounds in natural, domestic, and technological waters in an on-line mode. (orig.) [German] In vielen Umweltschutzanwendungen stellt die Auftrennung eines Substanzgemisches zum Zweck der Analyse eine sehr komplizierte Aufgabe dar. Ein erfolgversprechender Ansatz fuer eine on-line-Diagnostik besteht darin, das Objekt als integrale Spektroskopieprobe zu betrachten, die durch bestimmte spezifische Spektral-Fluoreszenz-Signaturen (SFS) charakterisiert wird. Diese werden als Fluoreszenz-Intensitaets-Matrix organischer Verbindungen in Wasser dargestellt, mit Anregungs- und Emissionsspektren als weiteren Koordinaten, wodurch ein dreidimensionales Spektrum entsteht. Spektrale Fenster der SFS sind definiert als Fluoreszenzcharakteristika von Funktionsgruppen organischer Substanzen in der Wasserprobe. Der auf diesem Prinzip basierende Skalar Fluo Imager ist fuer die on-line-Analyse organischer Bestandteile in natuerlichen, Haus- und technischen Waessern gedacht. (orig.)

  5. Automatic Delineation of On-Line Head-And-Neck Computed Tomography Images: Toward On-Line Adaptive Radiotherapy

    International Nuclear Information System (INIS)

    Zhang Tiezhi; Chi Yuwei; Meldolesi, Elisa; Yan Di

    2007-01-01

    Purpose: To develop and validate a fully automatic region-of-interest (ROI) delineation method for on-line adaptive radiotherapy. Methods and Materials: On-line adaptive radiotherapy requires a robust and automatic image segmentation method to delineate ROIs in on-line volumetric images. We have implemented an atlas-based image segmentation method to automatically delineate ROIs of head-and-neck helical computed tomography images. A total of 32 daily computed tomography images from 7 head-and-neck patients were delineated using this automatic image segmentation method. Manually drawn contours on the daily images were used as references in the evaluation of automatically delineated ROIs. Two methods were used in quantitative validation: (1) the dice similarity coefficient index, which indicates the overlapping ratio between the manually and automatically delineated ROIs; and (2) the distance transformation, which yields the distances between the manually and automatically delineated ROI surfaces. Results: Automatic segmentation showed agreement with manual contouring. For most ROIs, the dice similarity coefficient indexes were approximately 0.8. Similarly, the distance transformation evaluation results showed that the distances between the manually and automatically delineated ROI surfaces were mostly within 3 mm. The distances between two surfaces had a mean of 1 mm and standard deviation of <2 mm in most ROIs. Conclusion: With atlas-based image segmentation, it is feasible to automatically delineate ROIs on the head-and-neck helical computed tomography images in on-line adaptive treatments

  6. Simultaneous determination of palladium, platinum and rhodium by on-line column enrichment and HPLC with 2,4-dihydroxybenzylidenethiorhodanine as pre-column derivatization reagent

    Directory of Open Access Journals (Sweden)

    Dong Xuechang

    2006-01-01

    Full Text Available A new method for the simultaneous determination of palladium, platinum and rhodium ions as metal-DHBTR chelates was developed. The palladium, platinum and rhodium ions were pre-column derivatized with 2,4-dihydroxybenzylidenethiorhodanine (DHBTR to form colored chelates. The Pd-DHBTR, Pt-DHBTR and Rh-DHBTR chelates can be absorbed onto the front of the enrichment column when they were injected into the injector and sent to the enrichment column with a 0.05 mol L-1 sodium acetate-acetic acid buffer solution (pH 3.5 as mobile phase. After the enrichment had finished, by switching the six ports switching valve, the retained chelates were back-flushed by mobile phase and traveling towards the analytical column. These chelates separation on the analytical column was satisfactory with 62% (v/v acetonitrile (containing 0.05 mol L-1 of pH 3.5 sodium acetate-acetic acid buffer salt and 0.1% (m/v of tritonX-100 as mobile phase. The Limits of detection of palladium, platinum and rhodium are 3.6 ng L-1, 3.2 ng L-1 and 4.5 ng L-1, respectively. This method was applied to the determination of palladium, platinum and rhodium in water, urine and soil samples with good results.

  7. Targeted Diazotransfer Reagents Enable Selective Modification of Proteins with Azides.

    Science.gov (United States)

    Lohse, Jonas; Swier, Lotteke J Y M; Oudshoorn, Ruben C; Médard, Guillaume; Kuster, Bernhard; Slotboom, Dirk-Jan; Witte, Martin D

    2017-04-19

    In chemical biology, azides are used to chemically manipulate target structures in a bioorthogonal manner for a plethora of applications ranging from target identification to the synthesis of homogeneously modified protein conjugates. While a variety of methods have been established to introduce the azido group into recombinant proteins, a method that directly converts specific amino groups in endogenous proteins is lacking. Here, we report the first biotin-tethered diazotransfer reagent DtBio and demonstrate that it selectively modifies the model proteins streptavidin and avidin and the membrane protein BioY on cell surface. The reagent converts amines in the proximity of the binding pocket to azides and leaves the remaining amino groups in streptavidin untouched. Reagents of this novel class will find use in target identification as well as the selective functionalization and bioorthogonal protection of proteins.

  8. On-line soft sensing in upstream bioprocessing.

    Science.gov (United States)

    Randek, Judit; Mandenius, Carl-Fredrik

    2018-02-01

    This review provides an overview and a critical discussion of novel possibilities of applying soft sensors for on-line monitoring and control of industrial bioprocesses. Focus is on bio-product formation in the upstream process but also the integration with other parts of the process is addressed. The term soft sensor is used for the combination of analytical hardware data (from sensors, analytical devices, instruments and actuators) with mathematical models that create new real-time information about the process. In particular, the review assesses these possibilities from an industrial perspective, including sensor performance, information value and production economy. The capabilities of existing analytical on-line techniques are scrutinized in view of their usefulness in soft sensor setups and in relation to typical needs in bioprocessing in general. The review concludes with specific recommendations for further development of soft sensors for the monitoring and control of upstream bioprocessing.

  9. On-line corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Richter, Sonja; Thorarinsdottir, R.I.; Hilbert, Lisbeth Rischel

    2004-01-01

    ), Electrochemical Noise (EN) and Zero Resistance Ammetry (ZRA). Electrochemical Resistance (ER) has also been used to measure corrosion. The method traditionally only measures corrosion off-line but with newly developed high-sensitive ER technique developed by MetriCorr in Denmark, on-line monitoring is possible...... complicates the chemistry of the environment. Hydrogen sulphide is present in geothermal systems and can be formed as a by-product of sulphate-reducing-bacteria (SRB). The application of electrochemical methods makes on-line monitoring possible. These methods include: Linear Polarization Resistance (LPR....... In order to assess both general corrosion and localized corrosion, it is necessary to apply more than one monitoring technique simultaneously, ZRA or EN for measuring localized corrosion and LPR or ER for measuring general corrosion rate. The advantage of monitoring localized corrosion is indisputable...

  10. On-line sources of toxicological information in Canada

    International Nuclear Information System (INIS)

    Racz, William J.; Ecobichon, Donald J.; Baril, Marc

    2003-01-01

    This paper will provide an overview of the on-line resources available in toxicology in Canada. It will describe a brief history of The Society of Toxicology of Canada, with reference to other societies and also provide information on education, research and other resources related to toxicology. Toxicology in Canada emerged as a distinct and vibrant discipline following the thalidomide tragedy of the 1960s. In the pharmaceutical industry and government, toxicology was readily established as an essential component of drug development and safety, and as the need for toxicologists expanded, training programs were established, usually in collaboration with departments of pharmacology. In the last two to three decades other disciplines, environmental biology, analytical chemistry and epidemiology joined the ranks of toxicology. The on-line sources of toxicology information are rapidly expanding. This article describes those sources considered by the authors to be important from a national and international perspective. The majority of these sources are professional organizations and government agencies

  11. On-line chemistry monitoring for the secondary side

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    Babcock and Wilcox (B and W) has developed a computerized water chemistry data acquisition and management system for nuclear plant secondary coolant systems. The Integrated Water Chemistry Monitoring System (IWCMS) provides on-line monitoring of conditions and rapid trend analysis of sampled data. So far it has been installed at GPU Three Mile Island unit 1 and at Toledo Edison Davis-Besse. The IWCMS meets the following utility needs for monitoring power plant chemistry: control of chemistry conditions to minimize corrosion and extend component/system life; continuous analysis of data from on-line detectors and grab samples; expediting of transient recovery actions with trend, alarm and evaluation capability; provision for rapid sharing of useful operational chemistry information; concentration of attention on evaluation instead of data manipulation. The system is composed of three functional parts: data acquisition hardware; PC-based computer system and customised system software. (author)

  12. On-line application of the PANTHER advanced nodal code

    International Nuclear Information System (INIS)

    Hutt, P.K.; Knight, M.P.

    1992-01-01

    Over the last few years, Nuclear Electric has developed an integrated core performance code package for both light water reactors (LWRs) and advanced gas-cooled reactors (AGRs) that can perform a comprehensive range of calculations for fuel cycle design, safety analysis, and on-line operational support for such plants. The package consists of the following codes: WIMS for lattice physics, PANTHER whole reactor nodal flux and AGR thermal hydraulics, VIPRE for LWR thermal hydraulics, and ENIGMA for fuel performance. These codes are integrated within a UNIX-based interactive system called the Reactor Physics Workbench (RPW), which provides an interactive graphic user interface and quality assurance records/data management. The RPW can also control calculational sequences and data flows. The package has been designed to run both off-line and on-line accessing plant data through the RPW

  13. UniFlex - Collaborative on-line learning environment tool

    Directory of Open Access Journals (Sweden)

    Ole Borch

    2004-05-01

    Full Text Available

    Første gang publiceret i UNEV nr. 2: E-læringsplatforme - muligheder og potentialer, januar - marts 2004, red. Tom Nyvand og Michael Pedersen. ISSN 1603-5518.

    Increasing demands for remote on-line education are changing the way teaching and learning is performed. New behavior in using pedagogy and supporting technology is needed to drive the learning process. To facilitate the use of services for selected activities to participants in distance education, a web site named UniFlex (University Flexible learning has been developed and brought into use. The site is a comprehensive set of bookmarks including course taking, upload/download, and - of special significance - collaborative on-line project work. UniFlex has been developed to meet the requirement for a simple and cheap personalized interactive site, supporting problem oriented and project organized study form, which has characterized Aalborg University for more than 27 years.

  14. UniFlex - Collaborative on-line learning environment tool

    Directory of Open Access Journals (Sweden)

    Ole Borch

    2004-03-01

    Full Text Available Første gang publiceret i UNEV nr. 2: E-læringsplatforme - muligheder og potentialer, januar - marts 2004, red. Tom Nyvand og Michael Pedersen. ISSN 1603-5518. Increasing demands for remote on-line education are changing the way teaching and learning is performed. New behavior in using pedagogy and supporting technology is needed to drive the learning process. To facilitate the use of services for selected activities to participants in distance education, a web site named UniFlex (University Flexible learning has been developed and brought into use. The site is a comprehensive set of bookmarks including course taking, upload/download, and - of special significance - collaborative on-line project work. UniFlex has been developed to meet the requirement for a simple and cheap personalized interactive site, supporting problem oriented and project organized study form, which has characterized Aalborg University for more than 27 years.

  15. On-line analyzers to distributed control system linking

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, S.F.; Buchanan, B.R.; Sanders, M.A.

    1990-01-01

    The Analytical Development Section (ADS) of the Savannah River Laboratory is developing on-line analyzers to monitor various site processes. Data from some of the on-line analyzers (OLA's) will be used for process control by distributed control systems (DCS's) such as the Fisher PRoVOX. A problem in the past has been an efficient and cost effective way to get analyzer data onto the DCS data highway. ADS is developing a system to accomplish the linking of OLA's to PRoVOX DCS's. The system will be described, and results of operation in a research and development environment given. Plans for the installation in the production environment will be discussed.

  16. On-line Ramsey Numbers for Paths and Stars

    Directory of Open Access Journals (Sweden)

    Jaroslaw Grytczuk

    2008-08-01

    Full Text Available We study on-line version of size-Ramsey numbers of graphs defined via a game played between Builder and Painter: in one round Builder joins two vertices by an edge and Painter paints it red or blue. The goal of Builder is to force Painter to create a monochromatic copy of a fixed graph H in as few rounds as possible. The minimum number of rounds (assuming both players play perfectly is the on-line Ramsey number r(H of the graph H. We determine exact values of r(H for a few short paths and obtain a general upper bound r(Pn ≤ 4n-7. We also study asymmetric version of this parameter when one of the target graphs is a star Sn with n edges. We prove that r(Sn,H≤n ·e(H when H is any tree, cycle or clique.

  17. Laser systems for on-line laser ion sources

    International Nuclear Information System (INIS)

    Geppert, Christopher

    2008-01-01

    Since its initiation in the middle of the 1980s, the resonant ionization laser ion source has been established as a reliable and efficient on-line ion source for radioactive ion beams. In comparison to other on-line ion sources it comprises the advantages of high versatility for the elements to be ionized and of high selectivity and purity for the ion beam generated by resonant laser radiation. Dye laser systems have been the predominant and pioneering working horses for laser ion source applications up to recently, but the development of all-solid-state titanium:sapphire laser systems has nowadays initiated a significant evolution within this field. In this paper an overview of the ongoing developments will be given, which have contributed to the establishment of a number of new laser ion source facilities worldwide during the last five years.

  18. On-Line Metrology with Conoscopic Holography: Beyond Triangulation

    Directory of Open Access Journals (Sweden)

    Ignacio Álvarez

    2009-09-01

    Full Text Available On-line non-contact surface inspection with high precision is still an open problem. Laser triangulation techniques are the most common solution for this kind of systems, but there exist fundamental limitations to their applicability when high precisions, long standoffs or large apertures are needed, and when there are difficult operating conditions. Other methods are, in general, not applicable in hostile environments or inadequate for on-line measurement. In this paper we review the latest research in Conoscopic Holography, an interferometric technique that has been applied successfully in this kind of applications, ranging from submicrometric roughness measurements, to long standoff sensors for surface defect detection in steel at high temperatures.

  19. The Bochum on-line data acquisition system

    International Nuclear Information System (INIS)

    Paul, H.J.; Freiesleben, H.

    1986-01-01

    We describe an on-line data acquisition system based on a PDP 11 computer with CAMAC hardware. The software fully exploits the real-time features of the RSX-11M operating system. The basic characteristics of the program package, mainly written in FORTRAN 77, are: multitasking, shared common blocks, dynamical access to CAMAC hardware and data, and command orientated user interface. The system is particularly tailored for data acquisition in list mode of up to 64 parameters. (orig.)

  20. Recovery Strategies in On-Line Service Failure

    OpenAIRE

    Ozuem, Wilson; Lancaster, Geoff

    2013-01-01

    Despite a proliferation of a number of studies on service failures and recovery in e-service settings, there is a paucity of knowledge of ways in which service failures and recovery practices are implemented in the fashion industry. Drawing on constructivist perspective, this study offers a new perspective on an effective relational mechanism that would bridge the rupture between consumers and companies particularly in the on-line fashion sector. The analysis adds to studies on service failur...

  1. Understanding Cognitive Load Using On-line Dictionaries

    OpenAIRE

    Robert F. , Dilenschneider

    2017-01-01

    Cognitive Load Theory may useful for language instructors to understand how the look up conditions ofusing an on-line dictionary might influence learning. This paper first reviews previous studies that haveinvestigated dictionary use for vocabulary acquisition and reading comprehension Second, it explainsthe various elements of Cognitive Load Theory. Third, it describes how Cognitive Load Theory appliesto language learners' to learn unknown words and comprehend texts Last, it discusses the pe...

  2. On-line diagnostics for a real time system

    International Nuclear Information System (INIS)

    Sreenivasan, P.

    1976-01-01

    The purpose of an on-line diagnostics is to infuse the ability of self diagnosing in an online computer to enhance its dependability in a real time system. Such a diagnostics evolved for the CDPS of the Fast Breeder Test Reactor at Kalpakkam is reported. The two phases of the diagnostics, i.e., the malfunction detection and post detection action are described in some detail. (A.K.)

  3. Isocele I, the Orsay synchrocyclotron on-line separator

    International Nuclear Information System (INIS)

    Caruette, A.; Ferro, A.; Foucher, R.

    1976-01-01

    The main characteristics of the isotope separator Isocele 1 are described. This medium current separator was on line with the Orsay synchrocyclotron (155 MeV p, or 210 MeV 3 He) from March 1974 up to May 1975. Results obtained with different targets (Au, Bi, Er, Pt, Sn, Th) are summarized. They confirm the efficiency of medium current separators of this type [fr

  4. A decision support system for on-line leakage localization

    OpenAIRE

    Meseguer, Jordi; Mirats-Tur, Josep M.; Cembrano, Gabriela; Puig, Vicenç; Quevedo, Joseba; Pérez, Ramon; Sanz, Gerard; Ibarra, David

    2014-01-01

    This paper describes a model-driven decision-support system (software tool) implementing a model-based methodology for on-line leakage detection and localization which is useful for a large class of water distribution networks. Since these methods present a certain degree of complexity which limits their use to experts, the proposed software tool focuses on the integration of a method emphasizing its use by water network managers as a decision support system. The proposed software tool integr...

  5. On-line learning in radial basis functions networks

    OpenAIRE

    Freeman, Jason; Saad, David

    1997-01-01

    An analytic investigation of the average case learning and generalization properties of Radial Basis Function Networks (RBFs) is presented, utilising on-line gradient descent as the learning rule. The analytic method employed allows both the calculation of generalization error and the examination of the internal dynamics of the network. The generalization error and internal dynamics are then used to examine the role of the learning rate and the specialization of the hidden units, which gives ...

  6. On-line production of [11C]cyanogen bromide

    International Nuclear Information System (INIS)

    Westerberg, G.; Laangstroem, B.

    1997-01-01

    The electrophilic labelling precursor [ 11 C]cyanogen bromide was produced in 95% radiochemical yield (decay-corrected) from hydrogen [ 11 C]cyanide within 3 min from the end of bombardment using a simple and convenient solid-phase on-line procedure. The [ 11 C]cyanogen bromide has been used in the synthesis of a number of labelled compounds for use in positron emission tomography. (author)

  7. Silver di-t-butyl phosphate, a useful reagent in the synthesis of phospholipids. Synthesis of mixed-acid phosphatidic acid and phosphatidyl glycerolphosphate

    NARCIS (Netherlands)

    Bonsen, P.P.M.; Haas, Gerard H. de

    The synthesis of silver di-t-butyl phosphate is described. Using this reagent, mixed-acid phosphatidic acid with one unsaturated fatty acid could be prepared by means of a reaction with a 1,2-diacyl glycerol-3-iodohydrin. The blocking groups could be removed easily with dry hydrogen chloride at low

  8. On-line Monitoring System for Power Transformers

    Directory of Open Access Journals (Sweden)

    Alexandru HOTEA

    2016-12-01

    Full Text Available Power transformers are the most important and expensive equipment from the electricity transmission system, so it is very important to know the real state of health of such equipment in every moment. De-energizing the power transformer accidentally due to internal defects can generate high costs. Annual maintenance proved to be ineffective in many cases to determine the internal condition of the equipment degradation due to faults rapidly evolving. An On-line Monitoring System for Power Transformers help real-time condition assessment and to detect errors early enough to take action to eliminate or minimize them. After abnormality detected, it is still important to perform full diagnostic tests to determine the exact condition of the equipment. On-line monitoring systems can help increase the level of availability and reliability of power transformers and lower costs of accidental interruption. This paper presents cases studies on several power transformers equipped with on-line monitoring systems from Transelectrica substation.

  9. Characterizing chemical systems with on-line computers and graphics

    International Nuclear Information System (INIS)

    Frazer, J.W.; Rigdon, L.P.; Brand, H.R.; Pomernacki, C.L.

    1979-01-01

    Incorporating computers and graphics on-line to chemical experiments and processes opens up new opportunities for the study and control of complex systems. Systems having many variables can be characterized even when the variable interactions are nonlinear, and the system cannot a priori be represented by numerical methods and models. That is, large sets of accurate data can be rapidly acquired, then modeling and graphic techniques can be used to obtain partial interpretation plus design of further experimentation. The experimenter can thus comparatively quickly iterate between experimentation and modeling to obtain a final solution. We have designed and characterized a versatile computer-controlled apparatus for chemical research, which incorporates on-line instrumentation and graphics. It can be used to determine the mechanism of enzyme-induced reactions or to optimize analytical methods. The apparatus can also be operated as a pilot plant to design control strategies. On-line graphics were used to display conventional plots used by biochemists and three-dimensional response-surface plots

  10. On-Line Fringe Tracking and Prediction at IOTA

    Science.gov (United States)

    Wilson, Edward; Mah, Robert; Lau, Sonie (Technical Monitor)

    1999-01-01

    The Infrared/Optical Telescope Array (IOTA) is a multi-aperture Michelson interferometer located on Mt. Hopkins near Tucson, Arizona. To enable viewing of fainter targets, an on-line fringe tracking system is presently under development at NASA Ames Research Center. The system has been developed off-line using actual data from IOTA, and is presently undergoing on-line implementation at IOTA. The system has two parts: (1) a fringe tracking system that identifies the center of a fringe packet by fitting a parametric model to the data; and (2) a fringe packet motion prediction system that uses characteristics of past fringe packets to predict fringe packet motion. Combined, this information will be used to optimize on-line the scanning trajectory, resulting in improved visibility of faint targets. Fringe packet identification is highly accurate and robust (99% of the 4000 fringe packets were identified correctly, the remaining 1% were either out of the scan range or too noisy to be seen) and is performed in 30-90 milliseconds on a Pentium II-based computer. Fringe packet prediction, currently performed using an adaptive linear predictor, delivers a 10% improvement over the baseline of predicting no motion.

  11. Review of trigger and on-line processors at SLAC

    International Nuclear Information System (INIS)

    Lankford, A.J.

    1984-07-01

    The role of trigger and on-line processors in reducing data rates to manageable proportions in e + e - physics experiments is defined not by high physics or background rates, but by the large event sizes of the general-purpose detectors employed. The rate of e + e - annihilation is low, and backgrounds are not high; yet the number of physics processes which can be studied is vast and varied. This paper begins by briefly describing the role of trigger processors in the e + e - context. The usual flow of the trigger decision process is illustrated with selected examples of SLAC trigger processing. The features are mentioned of triggering at the SLC and the trigger processing plans of the two SLC detectors: The Mark II and the SLD. The most common on-line processors at SLAC, the BADC, the SLAC Scanner Processor, the SLAC FASTBUS Controller, and the VAX CAMAC Channel, are discussed. Uses of the 168/E, 3081/E, and FASTBUS VAX processors are mentioned. The manner in which these processors are interfaced and the function they serve on line is described. Finally, the accelerator control system for the SLC is outlined. This paper is a survey in nature, and hence, relies heavily upon references to previous publications for detailed description of work mentioned here. 27 references, 9 figures, 1 table

  12. On-line plant-wide monitoring using neural networks

    International Nuclear Information System (INIS)

    Turkcan, E.; Ciftcioglu, O.; Eryurek, E.; Upadhyaya, B.R.

    1992-06-01

    The on-line signal analysis system designed for a multi-level mode operation using neural networks is described. The system is capable of monitoring the plant states by tracking different number of signals up to 32 simultaneously. The data used for this study were acquired from the Borssele Nuclear Power Plant (PWR type), and using the on-line monitoring system. An on-line plant-wide monitoring study using a multilayer neural network model is discussed in this paper. The back-propagation neural network algorithm is used for training the network. The technique assumes that each physical state of the power plant can be represented by a unique pattern of instrument readings which can be related to the condition of the plant. When disturbance occurs, the sensor readings undergo a transient, and form a different set of patterns which represent the new operational status. Diagnosing these patterns can be helpful in identifying this new state of the power plant. To this end, plant-wide monitoring with neutral networks is one of the new techniques in real-time applications. (author). 9 refs.; 5 figs

  13. Designing effective on-line continuing medical education.

    Science.gov (United States)

    Zimitat, Craig

    2001-03-01

    The Internet, and new information and communication technologies available through the Internet, provides medical educators with an opportunity to develop unique on-line learning environments with real potential to improve physicians' knowledge and effect change in their clinical practice. There are approximately 100 websites offering on-line CME courses in the USA alone. However, few of these CME courses appear to be based on sound educational principles or CME research and may have little chance of achieving the broader goals of CME. The majority of these courses closely resemble their traditional counterparts (e.g. paper-based books are now electronic books) and appear to be mere substitutions for old-technology CME resources. Whilst some CME providers add unique features of the Internet to enrich their websites, they do not employ strategies to optimize the learning opportunities afforded by this new technology. The adoption of adult learning principles, reflective practice and problem-based approaches can be used as a foundation for sound CME course design. In addition, knowledge of Internet technology and the learning opportunities it affords, together with strategies to maintain participation and new assessment paradigms, are all needed for developing online CME. We argue for an evidence-based and strategic approach to the development of on-line CME courses designed to enhance physician learning and facilitate change in clinical behaviour.

  14. On-line fouling monitor for heat exchangers

    International Nuclear Information System (INIS)

    Tsou, J.L.

    1995-01-01

    Biological and/or chemical fouling in utility service water system heat exchangers adversely affects operation and maintenance costs, and reduced heat transfer capability can force a power deaerating or even a plant shut down. In addition, service water heat exchanger performance is a safety issue for nuclear power plants, and the issue was highlighted by NRC in Generic Letter 89-13. Heat transfer losses due to fouling are difficult to measure and, usually, quantitative assessment of the impact of fouling is impossible. Plant operators typically measure inlet and outlet water temperatures and flow rates and then perform complex calculations for heat exchanger fouling resistance or ''cleanliness''. These direct estimates are often imprecise due to inadequate instrumentation. Electric Power Research Institute developed and patented an on-line condenser fouling monitor. This monitor may be installed in any location within the condenser; does not interfere with routine plant operations, including on-line mechanical and chemical treatment methods; and provides continuous, real-time readings of the heat transfer efficiency of the instrumented tube. This instrument can be modified to perform on-line monitoring of service water heat exchangers. This paper discusses the design, construction of the new monitor, and algorithm used to calculate service water heat exchanger fouling

  15. Denmark's on - line early warning radiation monitoring network

    International Nuclear Information System (INIS)

    Walmod-Larsen, O.; Lippert, J.

    1990-01-01

    In Denmark an emergency response coordination committee was set up to cope with the problems after the Chernobyl accident with participation of all relevant authorities. For help in an emergency situation the ARGOS (Accident Reporting and Guiding Operational System), system will be put into use. The ARGOS emergency evaluation computer system, which has been developed in cooperation with the Danish Environmental Protection Agency, is in operation in connection with the emergency planning for the east region of Denmark with regard to the Swedish nuclear power plant operating at Barseback. Inputs of measurement data are on-line available on data screens for evaluation in the emergency coordination centers, presented on suitable geographical maps, showing iso-contours calculated from the input. In case of an alert situation other systems can be put in operation, f.ex. mobile measuring units from the CDEPA's local, operational emergency centers. Their readings can then be put into the computing system parallel to the on-line stations and be presented by the ARGOS-system for evaluation in the emergency command centers. If another national authority in an alert situation requests a transfer of measurement data, and if this is agreed upon by the competent Danish authority, then the transfer can be arranged from the ARGOS-system, through agreed transmission channels. At present the ARGOS system is being improved and expanded by RNL to cover the whole Danish region and to present measurements from the on-line warning system

  16. Estimation of 239Pu in urine, influence of Sulkowich reagent

    International Nuclear Information System (INIS)

    Kalaiselvan, S.; Prasad, M.V.R.; Jeevanram, R.K.

    1988-01-01

    Plutonium is known to be co-precipitated with Sulkowich reagent as calcium ammonium oxalate. In adopting this technique for bio-assay of plutonium, its accuracy depends on the self-absorption of the resulting precipitate in each urine sample. Pu recovery experiments were carried out with varying concentration of Ca and Mg, using different volumes of Sulkowich reagent. When the sample volume is 500 ml, Pu in urine can be estimated with an accuracy and precision of 74.38%+-7.4%, with a detection limit of 0.06 Bq (1.6 pCi) per dm 3 . (author) 3 refs.; 2 figs.; 2 tabs

  17. On-line supercritical fluid extraction-supercritical fluid chromatography-mass spectrometry of polycyclic aromatic hydrocarbons in soil.

    Science.gov (United States)

    Wicker, A Paige; Carlton, Doug D; Tanaka, Kenichiro; Nishimura, Masayuki; Chen, Vivian; Ogura, Tairo; Hedgepeth, William; Schug, Kevin A

    2018-06-01

    On-line supercritical fluid extraction - supercritical fluid chromatography - mass spectrometry (SFE-SFC-MS) has been applied for the determination of polycyclic aromatic hydrocarbons (PAHs) in soil. The purpose of this study was to develop and validate the first on-line SFE-SFC-MS method for the quantification of PAHs in various types of soil. By coupling the sample extraction on-line with chromatography and detection, sample preparation is minimized, diminishing sample loss and contamination, and significantly decreasing the required extraction time. Parameters for on-line extraction coupled to chromatographic analysis were optimized. The method was validated for concentrations of 10-1500 ng of PAHs per gram of soil in Certified Reference Material (CRM) sediment, clay, and sand with R 2  ≥ 0.99. Limits of detection (LOD) were found in the range of 0.001-5 ng/g, and limits of quantification (LOQ) in the range of 5-15 ng/g. The method developed in this study can be effectively applied to the study of PAHs in the environment, and may lay the foundation for further applications of on-line SFE-SFC-MS. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Specific binding assay technique; standardization of reagent

    International Nuclear Information System (INIS)

    Huggins, K.G.; Roitt, I.M.

    1979-01-01

    The standardization of a labelled constituent, such as anti-IgE, for use in a specific binding assay method is disclosed. A labelled ligand, such as IgE, is standardized against a ligand reference substance, such as WHO standard IgE, to determine the weight of IgE protein represented by the labelled ligand. Anti-light chain antibodies are contacted with varying concentrations of the labelled ligand. The ligand is then contacted with the labelled constituent which is then quantitated in relation to the amount of ligand protein present. The preparation of 131 I-labelled IgE is described. Also disclosed is an improved specific binding assay test method for determining the potency of an allergen extract in serum from an allergic individual. The improvement involved using a parallel model system of a second complex which consisted of anti-light chain antibodies, labelled ligand and the standardized labelled constituent (anti-IgE). The amount of standardized labelled constituent bound to the ligand in the first complex was determined, as described above, and the weight of ligand inhibited by addition of soluble allergen was then used as a measure of the potency of the allergen extract. (author)

  19. Improved radioimmunoassay for thyroid hormone and reagent

    International Nuclear Information System (INIS)

    1980-01-01

    Improvements in the radioimmunoassay of the thyroid hormones, thyroxine or triiodothyronine, are described. Hydrolyzed cross-linked polyacrylamide particles covalently bonded against the thyroid hormone are employed as solid phase substrates for the thyroid hormone antibodies. The polyacrylamide particles are dyed yellow or blue to facilitate the various manipulative steps during the radioimmunoassay. The particles are characterized by their ability to form stable hydrophilic suspensions. As a result the reaction mixture, during which thyroid hormone is separated from serum proteins and competitive binding in the presence of radioactive tracer with the antibody occurs, requires no agitation to maintain the desired homogeneous condition. This is in contrast to the settling problems experienced with cellulose, dextran and glass particles. In addition, the non-specific binding property of the polyacrylamide particles is so low that the initially separated solid phase particles following incubation can be directly measured for radioactivity levels without any initial washings thus increasing the speed and convenience of the assay procedure. Details of the preparation of the dyed, hydrolyzed polyacrylamide particles, the coupling of antiserum to these particles and the radioimmunoassay procedure are given. Data obtained from the radioimmunoassays of hypothyroid, euthyroid and hyperthyroid sera demonstrated the satisfactory performance of the assay. (U.K.)

  20. On-line digestion in a focused microwave-assisted oven for elements determination in orange juice by inductively coupled plasma optical emission spectrometry

    Directory of Open Access Journals (Sweden)

    Fili Sabrina P.

    2003-01-01

    Full Text Available A flow injection system coupled to focused microwave-assisted oven was used for on-line orange juice sample digestion for determination of Ca, Cu, Fe, K, Mg, Mn, Na, P, and Zn by inductively coupled plasma optical emission spectrometry. The reactor coil was a PTFE tube (4.0 m long and 1.6 mm i.d. positioned into the commercial glass tube of the focused microwave oven. Aliquots of 500 muL of sample and 1000 muL of reagent (80% v/v HNO3 were mixed in a confluence and carried out to the reactor coil by air carrier. The relative standard deviation for five replicates of sample was lower than 5.0%. Good recoveries varying from 91 to 111% were obtained for added concentrations of the interest elements. The results obtained using the proposed digestion system are in agreement with those obtained for total digestion at the 95% confidence level. With this on-line digestion system was possible to carry out 12 samples h-1, minimizing contamination, saving consumption of samples and reagent and low residue generation.

  1. Selective Flotation of Calcite from Fluorite: A Novel Reagent Schedule

    Directory of Open Access Journals (Sweden)

    Zhiyong Gao

    2016-10-01

    Full Text Available Fluorite is an important strategic mineral. In general, fluorite ores will contain a certain amount of calcite gangue mineral. Thus, they need to be separated from each other. For an economic separation, a reverse flotation process is used to float calcite gangue from fluorite. However, little information on the separation is available. In this study, a novel reagent schedule using citric acid (CA as the depressant, sodium fluoride (NaF as the regulator and sulfoleic acid (SOA as the collector, was developed to separate calcite from fluorite. The results demonstrated a high selectivity for the flotation of calcite from fluorite using this new reagent schedule. The best selective separation for a single mineral and mixed binary minerals was obtained when 200 mg/L of NaF, 50 mg/L of CA, and 6 mg/L of SOA were used at pH 9. In addition, a batch flotation experiment was carried out using a run-of-mine feed material. Selective separation was achieved with 85.18% calcite removal while only 11.2% of fluorite was lost. An attempt was made to understand the effect of the new reagent schedule on the flotation of calcite. The results from both microflotation and bench scale flotation demonstrated a great potential for industrial application using this novel reagent schedule to upgrade fluorite ore.

  2. Protein-Protein Interaction Reagents | Office of Cancer Genomics

    Science.gov (United States)

    The CTD2 Center at Emory University has a library of genes used to study protein-protein interactions in mammalian cells. These genes are cloned in different mammalian expression vectors. A list of available cancer-associated genes can be accessed below. Emory_CTD^2_PPI_Reagents.xlsx Contact: Haian Fu

  3. [Thermodynamic forecasting of reagents composition for soils decontamination].

    Science.gov (United States)

    Nikolaev, V P; Nikolaevskiĭ, V B; Chirkina, I V; Shcheglov, M Iu

    2009-01-01

    Based on thermodynamic studies, the authors conducted laboratory experiments on searching optimal composition of leaching reagents solution for soils decontamination, when contaminated with Cs-137, of activity coefficient for caesium sulfate microquantities in macrocomponents solutions. The method could be used for modelling the radionuclides phase equillibrium and relocations in soils.

  4. Lanthanide shift reagents, binding, shift mechanisms and exchange

    International Nuclear Information System (INIS)

    Boer, J.W.M. de

    1977-01-01

    Paramagnetic lanthanide shift reagents, when added to a solution of a substrate, induce shifts in the nuclear magnetic resonance (NMR) spectrum of the substrate molecules. The induced shifts contain information about the structure of the shift reagent substrate complex. The structural information, however, may be difficult to extract because of the following effects: (1) different complexes between shift reagent and substrate may be present in solution, e.g. 1:1 and 1:2 complexes, and the shift observed is a weighed average of the shifts of the substrate nuclei in the different complexes; (2) the Fermi contact interaction, arising from the spin density at the nucleus, contributes to the induced shift; (3) chemical exchange effects may complicate the NMR spectrum. In this thesis, the results of an investigation into the influence of these effects on the NMR spectra of solutions containing a substrate and LSR are presented. The equations describing the pseudo contact and the Fermi contact shift are derived. In addition, it is shown how the modified Bloch equations describing the effect of the chemical exchange processes occurring in the systems studied can be reduced to the familiar equations for a two-site exchange case. The binding of mono- and bifunctional ethers to the shift reagent are reported. An analysis of the induced shifts is given. Finally, the results of the experiments performed to study the exchange behavior of dimethoxyethane and heptafluorodimethyloctanedionato ligands are presented

  5. satl based lesson for teaching grignard reagents in synthetic organic

    African Journals Online (AJOL)

    IICBA01

    Traditionally, Grignard reagent has been very vital component of such synthetic ... knowledge, the systemic methodology of teaching and learning is the key point. Chemistry is ... chosen in particular to enlighten the students about effectiveness of systemic approach to .... Lectures through Systemic Approach to Teaching and.

  6. Investigation of cleaning reagents for calcium chromate spills

    International Nuclear Information System (INIS)

    Dillard, B.M.

    1979-01-01

    Cleaning of calcium chromate spills can be a problem due to the insolubility of the material and the corrosiveness of several possible cleaning agents on the stainless steel equipment. Because of OSHA Standards for Cr(VI) exposure, it is necessary to remove spills as efficiently as possible in order to prevent the contaminant from becoming airborne. This study involved the comparison of several possible cleaning agents by studying the solubility of calcium chromate in each reagent. Two general types of reagents for dissolution of calcium chromate were investigated; those which act by conversion of the insoluble calcium chromate to a more soluble salt and to H 2 CrO 4 , and those which appear to act as complexing agents and thereby dissolve the calcium chromate. The most efficient of the reagents investigated was hydrochloric acid. However, even dilute solutions of halide acids destroy passivity of stainless steel causing pitting and stress-corrosion. Acetic acid and nitric acid were somewhat less efficient than hydrochloric acid in dissolving calcium chromate. However, both reagents are noncorrosive with stainless steel, nitric acid tending to favor passivity of the materials. Therefore, it is recommended that dilute solutions of either of these two acids be used for removal of calcium chromate spills in conjunction with mechanical methods that might be necessary, depending on the magnitude of the spill

  7. Synthesis and characterization of zwitterionic carbon dioxide fixing reagents

    DEFF Research Database (Denmark)

    Mikkelsen, Mette; Jørgensen, Mikkel; Krebs, Frederik C

    2010-01-01

    with 13CO2 labeling and medium pressure NMR. The experiments showed that two of the three reagents were able to form carbamates and thus bind CO2. In addition we investigated this particular class of molecules for the possible formation of neutrally charged spiro compounds and we show that these did...

  8. 21 CFR 866.3145 - Coxsackievirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3145... fluorescent dye that are used to identify coxsackievirus from clinical specimens or from tissue culture isolates derived from clinical specimens. The identification aids in the diagnosis of coxsackievirus...

  9. 21 CFR 866.3085 - Brucella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3085 Brucella spp... from clinical specimens or to identify antibodies to Brucella spp. in serum. Additionally, some of... to identify Brucella spp. directly from clinical specimens or cultured isolates derived from clinical...

  10. 21 CFR 866.3510 - Rubella virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3510 Rubella virus... Clinical Laboratory Standards': (i) 1/LA6 “Detection and Quantitation of Rubella IgG Antibody: Evaluation... Products in the Clinical Laboratory, October 1997,” (ii) 1/LA18 “Specifications for Immunological Testing...

  11. Manganese-Catalyzed Aerobic Heterocoupling of Aryl Grignard Reagents

    DEFF Research Database (Denmark)

    Ghaleshahi, Hajar Golshahi; Antonacci, Giuseppe; Madsen, Robert

    2017-01-01

    An improved protocol has been developed for the MnCl2-catalyzed cross-coupling reaction of two arylmagnesium bromides under dioxygen. The reaction was achieved by using the Grignard reagents in a 2:1 ratio and 20 % of MnCl2. Very good yields of the heterocoupling product were obtained when the li...

  12. 21 CFR 864.1860 - Immunohistochemistry reagents and kits.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Immunohistochemistry reagents and kits. 864.1860 Section 864.1860 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Biological Stains § 864.1860...

  13. Evaluation of Questionnaire, Reagent Strip and Egg Count as ...

    African Journals Online (AJOL)

    A longitudinal study covering 55 months evaluated the three diagnostic tools used for confirmation of prevalence of urinary schistosomiasis among 1151 consented primary school pupils in 13 communities of Edo State, Nigeria. Questionnaire, reagent strip method and parasitological examination were employed.

  14. Radioimmunoassay reagent and its use in a radioimmunoassay

    International Nuclear Information System (INIS)

    Polito, A.J.; Knight, W.S.

    1977-01-01

    A radioimmunoassay to detect or determine a steroid of the cortisone and aldosterone group has been developed. The invention particularly concerns a steroid derivative containing imidazole group which is radioactively labelled. The invented reagents are labelled with iodine 125. (VJ) [de

  15. SATL Based Lesson for Teaching Grignard Reagents in Synthetic ...

    African Journals Online (AJOL)

    Synthesizing new products from raw materials has been very popular aspects of research in organic chemistry. Traditionally, Grignard reagent has been very vital component of such synthetic procedures. Hence learning of various issues concerning with applications of Grignard reactions in synthetic organic chemistry is ...

  16. Reaction of lupane and oleanane triterpenoids with Lawesson's reagent

    Czech Academy of Sciences Publication Activity Database

    Kvasnica, Miroslav; Rudovská, I.; Císařová, I.; Šarek, J.

    2008-01-01

    Roč. 64, č. 17 (2008), s. 3736-3743 ISSN 0040-4020 Grant - others:GA ČR(CZ) GP203/05/P025 Institutional research plan: CEZ:AV0Z40550506 Keywords : terpenoids * Lawesson's reagent * ketones * sulfur Subject RIV: CC - Organic Chemistry Impact factor: 2.897, year: 2008

  17. International reference reagents: antihuman globulin. An ISBT/ICSH joint working party report. International Society of Blood Transfusion. International Committee for Standardization in Haematology.

    Science.gov (United States)

    Case, J; Ford, D S; Chung, A; Collins, R; Kochman, S; Mazda, T; Overbeeke, M; Perera, R; Sakuldamrongpanich, T; Scott, M; Voak, D; Zupańska, B

    1999-01-01

    An international working party has conducted a study designed to select a suitable reference reagent for antihuman globulin, to replace those first made available in 1987. The chosen preparation contains levels of anti-IgG and anti-C3 (anti-C3c and anti-C3d) potency that are considered suitable to serve for reference when evaluating either polyspecific antihuman globulin reagents or those containing their separate monospecific components. The reference material is available in 2-ml freeze-dried aliquots from seven assigned distribution centres.

  18. In the Jungle of Astronomical On--line Data Services

    Science.gov (United States)

    Egret, D.

    The author tried to survive in the jungle of astronomical on--line data services. In order to find efficient answers to common scientific data retrieval requests, he had to collect many pieces of information, in order to formulate typical user scenarios, and try them against a number of different data bases, catalogue services, or information systems. He discovered soon how frustrating treasure coffers may be when their keys are not available, but he realized also that nice widgets and gadgets are of no help when the information is not there. And, before long, he knew he would have to navigate through several systems because no one was yet offering a general answer to all his questions. I will present examples of common user scenarios and show how they were tested against a number of services. I will propose some elements of classification which should help the end-user to evaluate how adequate the different services may be for providing satisfying answers to specific queries. For that, many aspects of the user interaction will be considered: documentation, access, query formulation, functionalities, qualification of the data, overall efficiency, etc. I will also suggest possible improvements to the present situation: the first of them being to encourage system managers to increase collaboration between one another, for the benefit of the whole astronomical community. The subjective review I will present, is based on publicly available astronomical on--line services from the U.S. and from Europe, most of which (excepting the newcomers) were described in ``Databases and On-Line Data in Astronomy", (Albrecht & Egret, eds, 1991): this includes databases (such as NED and Simbad ), catalog services ( StarCat , DIRA , XCatScan , etc.), and information systems ( ADS and ESIS ).

  19. On-line implant reconstruction in HDR brachytherapy

    International Nuclear Information System (INIS)

    Kolkman-Deurloo, Inger-Karine K.; Kruijf, Wilhelmus J.M. de; Levendag, Peter C.

    2006-01-01

    Background and purpose: To evaluate the accuracy of on-line planning in an Integrated Brachytherapy Unit (IBU) using dedicated image distortion correction algorithms, correcting the geometric distortion and magnetic distortion separately, and to determine the effect of the reconstruction accuracy on clinical treatment plans in terms of deviations in treatment time and dose. Patients and methods: The reconstruction accuracy has been measured using 20 markers, positioned at well known locations in a QA phantom. Treatment plans of two phantoms representing clinical implant geometries, have been compared with reference plans to determine the effect of the reconstruction accuracy on the treatment plan. Before clinical introduction, treatment plans of three representative patients, based on on-line reconstruction, have been compared with reference plans. Results: The average reconstruction error for 10 in. images reduces from -0.6 mm (range -2.6 to +1.0 mm) to -0.2 mm (range -1.2 to +0.6 mm) after image distortion correction and for 15 in. images from 0.8 mm (range -0.5 to +3.0 mm) to 0.0 mm (range -0.8 to +0.8 mm). The error in case of eccentric positioning of the phantom, i.e. 0.8 mm (range -1.0 to +3.3 mm), reduces to 0.1 mm (range -0.5 to +0.9 mm). Correction of the image distortions reduces the deviation in the calculated treatment time of maximally 2.7% to less than 0.8% in case of eccentrically positioned clinical phantoms. The deviation in the treatment time or reference dose in the plans based on on-line reconstruction with image distortion correction of the three patient examples is smaller than 0.3%. Conclusions: Accurate on-line implant reconstruction using the IBU localiser and dedicated correction algorithms separating the geometric distortion and the magnetic distortion is possible. The results fulfill the minimum requirements as imposed by the Netherlands Commission on Radiation Dosimetry (NCS) without limitations regarding the usable range of the field

  20. On-line data processing for scintillation camera

    International Nuclear Information System (INIS)

    Ueyanagi, Hideo

    1974-01-01

    To process on-line the information from scintillation cameras, the computing/processing device of wired program type, with a specialized mini-computer for the processing, is generally used; and by this method, the data processing is done by the users of scintillation cameras. In the device with a mini-computer with processing programming by software, the almost all items in processing can be executed; but the operation requires some skill. With mini-computer operation, on the other hand, there are the problems of data-point number, process-time reduction, and image storage for both long and short terms. (Mori, K.)

  1. Robust Control Methods for On-Line Statistical Learning

    Directory of Open Access Journals (Sweden)

    Capobianco Enrico

    2001-01-01

    Full Text Available The issue of controlling that data processing in an experiment results not affected by the presence of outliers is relevant for statistical control and learning studies. Learning schemes should thus be tested for their capacity of handling outliers in the observed training set so to achieve reliable estimates with respect to the crucial bias and variance aspects. We describe possible ways of endowing neural networks with statistically robust properties by defining feasible error criteria. It is convenient to cast neural nets in state space representations and apply both Kalman filter and stochastic approximation procedures in order to suggest statistically robustified solutions for on-line learning.

  2. Development of an on-line radon monitoring system

    International Nuclear Information System (INIS)

    Guo Huiping; Shang Aiguo; Liu Junfeng; Zhou Chunlin; Di Yuming

    2004-01-01

    Of the actual demand by the strategic missile troops, the author has successfully developed a specially designed passive diffusion collecting chamber to collect the decay products of radon by high voltage static electricity, and using the single-chip microcomputer to reckon the radon concentration in air, which is actually a portable, continuous and automatic on-line monitoring instrument. It was made into a four-slot standard plug-in board of a NIM, and it functions as auto data memory, data process, display, over-threshold alarming and so on. (authors)

  3. Integrated on-line accelerator modeling at CEBAF

    International Nuclear Information System (INIS)

    Bowling, B.A.; Shoaee, H.; Van Zeijts, J.; Witherspoon, S.; Watson, W.

    1995-01-01

    An on-line accelerator modeling facility is currently under development at CEBAF. The model server, which is integrated with the EPICS control system, provides coupled and 2nd-order matrices for the entire accelerator, and forms the foundation for automated model- based control and diagnostic applications. Four types of machine models are provided, including design, golden or certified, live, and scratch or simulated model. Provisions are also made for the use of multiple lattice modeling programs such as DIMAD, PARMELA, and TLIE. Design and implementation details are discussed. 2 refs., 4 figs

  4. On-line Dynamic Security Assessment in Power Systems

    DEFF Research Database (Denmark)

    Weckesser, Johannes Tilman Gabriel

    and solar radiation. Moreover, ongoing research suggests that demand response will be introduced to maintain power balance between generation and consumption at all times. Due to these changes the operating point of the power system will be less predictable and today’s stability and security assessment...... for early prediction of critical voltage sags is described. The method’s performance is compared to other prediction approaches. The results show that the proposed method succeeds in early, accurately and consistently predicting critically low voltage sags. An efficient on-line DSA not only identifies...

  5. Enhancing Learner Autonomy in an On-line Editing Programme

    Directory of Open Access Journals (Sweden)

    Hebe Wong

    2011-09-01

    Full Text Available Little (1999 argues that in formal educational contexts, “the basis of learner autonomy is acceptance of responsibility for one’s own learning” (p.11. An autonomous learner takes responsibility for various aspects of learning (Benson & Voller, 1997; Holec, 1981. This study examines how learner autonomy opportunities were provided at various stages of writing in an on-line editing programme for a group of electronic engineering students and how the students took charge of their language learning when receiving feedback on their technical writing. The impact on their own learning effectiveness of the decisions students made is also discussed.

  6. Investigating on-line pornography at the University of Johannesburg

    Directory of Open Access Journals (Sweden)

    P. Laughton

    2007-12-01

    (61,6% aged between 19 years and 21 years. Of the respondents, 36,7% indicated that exposure to unsolicited pornography did not bother them. When asked to what extent students should have access to pornography, 60,5% stated 'None' while 32,6% believed that 'Restricted' access should be granted for research purposes and 6,9% believed that students should be granted 'Total' access to pornography. Results from the research will be used to manage access to on-line resources at the University of Johannesburg better.

  7. On-line core monitoring with CORE MASTER / PRESTO

    International Nuclear Information System (INIS)

    Lindahl, S.O.; Borresen, S.; Ovrum, S.

    1986-01-01

    Advanced calculational tools are instrumental in improving reactor plant capacity factors and fuel utilization. The computer code package CORE MASTER is an integrated system designed to achieve this objective. The system covers all main activities in the area of in-core fuel management for boiling water reactors; design, operation support, and on-line core monitoring. CORE MASTER operates on a common data base, which defines the reactor and documents the operating history of the core and of all fuel bundles ever used

  8. Core on-line monitoring and computerized procedures systems

    International Nuclear Information System (INIS)

    Gangloff, W.C.

    1986-01-01

    The availability of operating nuclear power plants has been affected significantly by the difficulty people have in coping with the complexity of the plants and the operating procedures. Two ways to use modern computer technology to ease the burden of coping are discussed in this paper, an on-line core monitoring system with predictive capability and a computerized procedures system using live plant data. These systems reduce human errors by presenting information rather than simply data, using the computer to manipulate the data, but leaving the decisions to the plant operator

  9. Lower Bounds and Semi On-line Multiprocessor Scheduling

    Directory of Open Access Journals (Sweden)

    T.C. Edwin Cheng

    2003-10-01

    Full Text Available We are given a set of identical machines and a sequence of jobs from which we know the sum of the job weights in advance. The jobs have to be assigned on-line to one of the machines and the objective is to minimize the makespan. An algorithm with performance ratio 1.6 and a lower bound of 1.5 is presented. This improves recent results by Azar and Regev who published an algorithm with performance ratio 1.625 for the less general problem that the optimal makespan is known in advance.

  10. Adaptive calibration method with on-line growing complexity

    Directory of Open Access Journals (Sweden)

    Šika Z.

    2011-12-01

    Full Text Available This paper describes a modified variant of a kinematical calibration algorithm. In the beginning, a brief review of the calibration algorithm and its simple modification are described. As the described calibration modification uses some ideas used by the Lolimot algorithm, the algorithm is described and explained. Main topic of this paper is a description of a synthesis of the Lolimot-based calibration that leads to an adaptive algorithm with an on-line growing complexity. The paper contains a comparison of simple examples results and a discussion. A note about future research topics is also included.

  11. The development of an on-line gold analyser

    International Nuclear Information System (INIS)

    Robert, R.V.D.; Ormrod, G.T.W.

    1982-01-01

    An on-line analyser to monitor the gold in solutions from the carbon-in-pulp process is described. The automatic system is based on the delivery of filtered samples of the solutions to a distribution valve for measurement by flameless atomic-absorption spectrophotometry. The samples is introduced by the aerosol-deposition method. Operation of the analyser on a pilot plant and on a full-scale carbon-in-pulp plant has shown that the system is economically feasible and capable of providing a continuous indication of the efficiency of the extraction process

  12. NNDC [National Nuclear Data Center] on-line services documentation

    International Nuclear Information System (INIS)

    Dunford, C.L.; Burrows, T.W.; Tuli, J.K.

    1987-01-01

    This document summarizes and describes how to access the on-line services available from the National Nuclear Data Center (NNDC) located at Brookhaven National Laboratory. The services are available free of cost to US Department of Energy, its contractors and others who support the NNDC or supply data to the NNDC. Four of the center's data bases are now accessible to non-NNDC scientists via remote connection to the center's VAX 11/780. To use this service, you must have a terminal with access by either a telephone line or the PHYSNET network. A VT100 terminal or a terminal with VT-100 emulation is recommended but not required

  13. Efficient and Secure Comparison for On-Line Auctions

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Krøigaard, Mikkel; Geisler, Martin Joakim

    2007-01-01

    We propose a protocol for secure comparison of integers based on homomorphic encryption. We also propose a homomorphic encryption scheme that can be used in our protocol and makes it more efficient than previous solutions. Our protocol is well-suited for application in on-line auctions, both...... with respect to functionality and performance. It minimizes the amount of information bidders need to send, and for comparison of 16 bit numbers with security based on 1024 bit RSA (executed by two parties), our implementation takes 0.28 seconds including all computation and communication. Using precomputation...

  14. On-line computing in a classified environment

    International Nuclear Information System (INIS)

    O'Callaghan, P.B.

    1982-01-01

    Westinghouse Hanford Company (WHC) recently developed a Department of Energy (DOE) approved real-time, on-line computer system to control nuclear material. The system simultaneously processes both classified and unclassified information. Implementation of this system required application of many security techniques. The system has a secure, but user friendly interface. Many software applications protect the integrity of the data base from malevolent or accidental errors. Programming practices ensure the integrity of the computer system software. The audit trail and the reports generation capability record user actions and status of the nuclear material inventory

  15. On-line fatigue monitoring and margins probabilistic assessment

    International Nuclear Information System (INIS)

    Fournier, I.; Morilhat, P.

    1993-01-01

    An on-line computer aided system has been developed by Electricite de France, the French utility, for a fatigue monitoring of critical locations in the nuclear steam supply system. This tool, called fatiguemeter, includes as input data only existing plant parameters and is based on some conservative assumptions at several steps of the damage assessment (thermal boundary conditions, stress computation...). This paper presents recent developments performed toward a better assessing of margins involved in the complete analysis. The methodology is enlightened with an example showing the influence of plant parameters incertitude on the final stress computed at a PWR 900 MW unit pressurizer surge line nozzle. (author)

  16. On-line system for investigation of atomic structure

    International Nuclear Information System (INIS)

    Amus'ya, M.Ya.; Chernysheva, L.V.

    1983-01-01

    A description of the on-line ATOM system is presented that enables to investigate the structure of atomic electron shells and their interactions with different scattering particles-electrons, positronse photons, mesons - with the use of computerized numerical solutions. The problem is stated along with mathematical description of atomic properties including theoretical and numerical models for each investigated physical process. The ATOM system structure is considered. The Hartree-Fock method is used to determine the wave functions of the ground and excited atomic states. The programs are written in the ALGOL langauge. Different atomic characteristics were possible to be calculated for the first time with an accuracy exceeding an experimental one

  17. ELT-MELAS analyzer and its on-line programs

    International Nuclear Information System (INIS)

    Anikeev, V.B.; Berezhnoj, V.A.; Glupova

    1976-01-01

    ELT-MELAS device constructed for an automatic analysis of pictures from big bubble chambers is described. It is controlled by a medium-size ICL-1903A computer and has two measuring modes: analysis of the ''agreement'' signal and digitation of slice-scans. Main features of the hardware and of on-line controlling and diagnostic software are presented. The test results of the MELAS complex as well as preliminary results of the scan-slice measurements of pictures from 15sup(') chamber are given

  18. Development of versatile universal reagent immunoradiometric assay technique

    International Nuclear Information System (INIS)

    Hazra, D.K.

    1982-10-01

    Immunoradiometric assays, which make use of labelled antibodies, potentially offer better sensitivity and specificity than do radioimmunoassays, which use labelled antigens. In addition, they can in principle be performed in a particularly convenient scheme wherein the same labelled reagent may be used for many different analytes - thus serving as a ''universal'' labelled reagent. Thus if the specific antibody for every analyte is raised in rabbits, and an anti-rabbit antibody is labelled, the latter may be added after the specific antibody to quantify the amount of specific antibody bound to analyte and thereby the amount of analyte present. The potential greater sensitivity and specificity of the immunoradiometric procedure, coupled with the potential convenience of the ''universal'' labelled reagent, might allow such immunoradiometric techniques to be used effectively in the study of communicable diseases in developing countries. Development of these procedures was the subject of this investigation. Many components of these procedures had to be explored and provisionally optimized, including coating of assay tubes with ''extraction'' antibody, immunological purification of antibodies, labelling of antibodies, and intermediate steps toward these goals. Applications were thereupon tested using those provisionally optimized components. The ''universal'' labelled reagent, a donkey anti-rabbit antiserum, was successfully used in the assay of TSH; however, cross reactions of the reagent with non-rabbit immunoglobulins and other materials present seriously limited the sensitivity of the method. Using conventional immunoradiometric procedures, circulating TB and amoebic antibodies could be detected in patients suffering from these diseases. Similarly, circulating antigens in the same patients could also be detected, but not with sufficient sensitivity and specificity to provide a reliable analytical system. Numerous improvements will be required before these techniques

  19. Azidoimidazolinium Salts: Safe and Efficient Diazo-transfer Reagents and Unique Azido-donors.

    Science.gov (United States)

    Kitamura, Mitsuru

    2017-07-01

    2-Azido-1,3-dimethylimidazolinium chloride (ADMC) and its corresponding hexafluorophosphate (ADMP) were found to be efficient diazo-transfer reagents to various organic compounds. ADMC was prepared by the reaction of 2-chloro-1,3-dimethylimidazolinium chloride (DMC) and sodium azide. ADMP was isolated as a crystal having good thermal stability and low explosibility. ADMC and ADMP reacted with 1,3-dicarbonyl compounds under mild basic conditions to give 2-diazo-1,3-dicarbonyl compounds in high yields, which were easily isolated in virtue of the high water solubility of the by-products. ADMP showed high diazo-transfer ability to primary amines even in the absence of metal salt such as Cu(II). Using this diazotization approach, various alkyl/aryl azides were directly obtained from their corresponding primary amines in high yields. Furthermore, naphthols reacted with ADMC to give the corresponding diazonaphthoquinones in good to high yields. In addition, 2-azido-1,3-dimethylimidazolinium salts were employed as azide-transfer and migratory amidation reagents. © 2017 The Chemical Society of Japan & Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. A Field-Portable Cell Analyzer without a Microscope and Reagents.

    Science.gov (United States)

    Seo, Dongmin; Oh, Sangwoo; Lee, Moonjin; Hwang, Yongha; Seo, Sungkyu

    2017-12-29

    This paper demonstrates a commercial-level field-portable lens-free cell analyzer called the NaviCell (No-stain and Automated Versatile Innovative cell analyzer) capable of automatically analyzing cell count and viability without employing an optical microscope and reagents. Based on the lens-free shadow imaging technique, the NaviCell (162 × 135 × 138 mm³ and 1.02 kg) has the advantage of providing analysis results with improved standard deviation between measurement results, owing to its large field of view. Importantly, the cell counting and viability testing can be analyzed without the use of any reagent, thereby simplifying the measurement procedure and reducing potential errors during sample preparation. In this study, the performance of the NaviCell for cell counting and viability testing was demonstrated using 13 and six cell lines, respectively. Based on the results of the hemocytometer ( de facto standard), the error rate (ER) and coefficient of variation (CV) of the NaviCell are approximately 3.27 and 2.16 times better than the commercial cell counter, respectively. The cell viability testing of the NaviCell also showed an ER and CV performance improvement of 5.09 and 1.8 times, respectively, demonstrating sufficient potential in the field of cell analysis.

  1. Human comment dynamics in on-line social systems

    Science.gov (United States)

    Wu, Ye; Zhou, Changsong; Chen, Maoying; Xiao, Jinghua; Kurths, Jürgen

    2010-12-01

    Human comment is studied using data from ‘tianya’ which is one of the most popular on-line social systems in China. We found that the time interval between two consecutive comments on the same topic, called inter-event time, follows a power-law distribution. This result shows that there is no characteristic decay time on a topic. It allows for very long periods without comments that separate bursts of intensive comments. Furthermore, the frequency of a different ID commenting on a topic also follows a power-law distribution. It indicates that there are some “hubs” in the topic who lead the direction of the public opinion. Based on the personal comments habit, a model is introduced to explain these phenomena. The numerical simulations of the model fit well with the empirical results. Our findings are helpful for discovering regular patterns of human behavior in on-line society and the evolution of the public opinion on the virtual as well as real society.

  2. On-Line Core Thermal-Hydraulic Model Improvement

    International Nuclear Information System (INIS)

    In, Wang Kee; Chun, Tae Hyun; Oh, Dong Seok; Shin, Chang Hwan; Hwang, Dae Hyun; Seo, Kyung Won

    2007-02-01

    The objective of this project is to implement a fast-running 4-channel based code CETOP-D in an advanced reactor core protection calculator system(RCOPS). The part required for the on-line calculation of DNBR were extracted from the source of the CETOP-D code based on analysis of the CETOP-D code. The CETOP-D code was revised to maintain the input and output variables which are the same as in CPC DNBR module. Since the DNBR module performs a complex calculation, it is divided into sub-modules per major calculation step. The functional design requirements for the DNBR module is documented and the values of the database(DB) constants were decided. This project also developed a Fortran module(BEST) of the RCOPS Fortran Simulator and a computer code RCOPS-SDNBR to independently calculate DNBR. A test was also conducted to verify the functional design and DB of thermal-hydraulic model which is necessary to calculate the DNBR on-line in RCOPS. The DNBR margin is expected to increase by 2%-3% once the CETOP-D code is used to calculate the RCOPS DNBR. It should be noted that the final DNBR margin improvement could be determined in the future based on overall uncertainty analysis of the RCOPS

  3. Utilities enticing customers to come on-line

    International Nuclear Information System (INIS)

    Anon

    2000-01-01

    The first tentative steps by electric utilities to offer customer services on-line is reported. While most of the on-line communications to date has been merely to present information about products and services, at least a few utilities, -- Newfoundland Power being one of them -- are now offering customers the opportunity to check on their account status, to make inquiries, and on a voluntary basis employees of the utility can receive their bills on the web. BC Hydro is even more advanced; it has offered a similar service since 1997. The option to pay bills at the BC Hydro website is coming shortly. U. S. utility companies are reported to be far more advanced in the use of the Internet; according to a study by Deloitte Consulting, U.S. utilities are advancing to the next stage wherein Web intermediaries will be offering 'shop bots' that do comparison shopping on behalf of a customer, including bidding for power on a customer's behalf at energy auctions, reverse auctions, where sellers are bidding for customers' services, and buyers clubs where customers join together to take advantage of volume buying power

  4. On-line monitoring and inservice inspection in codes

    International Nuclear Information System (INIS)

    Bartonicek, J.; Zaiss, W.; Bath, H.R.

    1999-01-01

    The relevant regulatory codes determine the ISI tasks and the time intervals for recurrent components testing for evaluation of operation-induced damaging or ageing in order to ensure component integrity on the basis of the last available quality data. In-service quality monitoring is carried out through on-line monitoring and recurrent testing. The requirements defined by the engineering codes elaborated by various institutions are comparable, with the KTA nuclear engineering and safety codes being the most complete provisions for quality evaluation and assurance after different, defined service periods. German conventional codes for assuring component integrity provide exclusively for recurrent inspection regimes (mainly pressure tests and optical testing). The requirements defined in the KTA codes however always demanded more specific inspections relying on recurrent testing as well as on-line monitoring. Foreign codes for ensuring component integrity concentrate on NDE tasks at regular time intervals, with time intervals scope of testing activities being defined on the basis of the ASME code, section XI. (orig./CB) [de

  5. Polar On-Line Acquisition Relay and Transmission System (POLARATS)

    Energy Technology Data Exchange (ETDEWEB)

    Yuracko, K.

    2004-07-15

    POLARATS (Polar On-Line Acquisition Relay And Transmission System) is being developed by YAHSGS LLC (YAHSGS) and Oak Ridge National Laboratory (ORNL) to provide remote, unattended monitoring of environmental parameters under harsh environmental conditions. In particular, instrumental design and engineering is oriented towards protection of human health in the Arctic, and with the additional goal of advancing Arctic education and research. POLARATS will obtain and transmit environmental data from hardened monitoring devices deployed in locations important to understanding atmospheric and aquatic pollutant migration as it is biomagnified in Arctic food chains. An Internet- and personal computer (PC)-based educational module will provide real time sensor data, on-line educational content, and will be integrated with workbooks and textbooks for use in middle and high school science programs. The educational elements of POLARATS include an Internet-based educational module that will instruct students in the use of the data and how those data fit into changing Arctic environments and food chains. POLARATS will: (1) Enable students, members of the community, and scientific researchers to monitor local environmental conditions in real time over the Internet; and (2) Provide additional educational benefits through integration with middle- and high-school science curricula. Information will be relayed from POLARATS devices to classrooms and libraries along with custom-designed POLARATS teaching materials that will be integrated into existing curricula to enhance the educational benefits realized from the information obtained.

  6. Aria Sardinia: the on line community joining tradition and innovatiom

    Directory of Open Access Journals (Sweden)

    Fabrizio Lao

    2005-12-01

    Full Text Available The "ARIA Sardinia" project (Network Actions for Italians Abroad has been especially designed to integrate and give value to the network of relationships between public administrations, local socio-economic stakeholders and Italian communities abroad, this goal to be pursued with the support of new technologies and learning approaches emerging within the context of on line interest communities. The general objective of the project is the development of competencies and knowledge, intended to combine specific technical skills with local "territorial knowledge", in a process where the strengthening and the dissemination of these forms of culture come from the prompt use of innovative tools. The main activities of the project are the actions intended to guide and assist entrepreneurs, associations, development projects' partners or promoters in the path of acquisition and dissemination of the competencies which are necessary to the involvement of Italians abroad into the internationalization process of Sardinian economy. ARIA Sardinia was funded by the Italian Foreign Affairs Ministry and the European Social Fund (FSE, within the framework of the National Operational Program for Technical Assistance and System Action (PON ATAS aimed at specific promotion initiatives and fostering of permanent links between Southern Italy economy and Italians living abroad. Keywords: on line community, networking, Italians abroad, Sardinian economy, Sardinia, culture.

  7. On-Line Core Thermal-Hydraulic Model Improvement

    Energy Technology Data Exchange (ETDEWEB)

    In, Wang Kee; Chun, Tae Hyun; Oh, Dong Seok; Shin, Chang Hwan; Hwang, Dae Hyun; Seo, Kyung Won

    2007-02-15

    The objective of this project is to implement a fast-running 4-channel based code CETOP-D in an advanced reactor core protection calculator system(RCOPS). The part required for the on-line calculation of DNBR were extracted from the source of the CETOP-D code based on analysis of the CETOP-D code. The CETOP-D code was revised to maintain the input and output variables which are the same as in CPC DNBR module. Since the DNBR module performs a complex calculation, it is divided into sub-modules per major calculation step. The functional design requirements for the DNBR module is documented and the values of the database(DB) constants were decided. This project also developed a Fortran module(BEST) of the RCOPS Fortran Simulator and a computer code RCOPS-SDNBR to independently calculate DNBR. A test was also conducted to verify the functional design and DB of thermal-hydraulic model which is necessary to calculate the DNBR on-line in RCOPS. The DNBR margin is expected to increase by 2%-3% once the CETOP-D code is used to calculate the RCOPS DNBR. It should be noted that the final DNBR margin improvement could be determined in the future based on overall uncertainty analysis of the RCOPS.

  8. The Automated Threaded Fastening Based on On-line Identification

    Directory of Open Access Journals (Sweden)

    Nicolas Ivan Giannoccaro

    2008-11-01

    Full Text Available The principle of the thread fastenings have been known and used for decades with the purpose of joining one component to another. Threaded fastenings are popular because they permit easy disassembly for maintenance, repair, relocation and recycling. Screw insertions are typically carried out manually. It is a difficult problem to automat. As a result there is very little published research on automating threaded fastenings, and most research on automated assembly focus on the peg-in-hole assembly problem. This paper investigates the problem of automated monitoring of the screw insertion process. The monitoring problem deals with predicting integrity of a threaded insertion, based on the torque vs. insertion depth curve generated during the insertions. The authors have developed an analytical model to predict the torque signature signals during self-tapping screw insertions. However, the model requires parameters on the screw dimensions and plate material properties are difficult to measure. This paper presents a study on on-line identification during screw fastenings. An identification methodology for two unknown parameter estimation during a self-tapping screw insertion process is presented. It is shown that friction and screw properties required by the model can be reliably estimated on-line. Experimental results are presented to validate the identification procedure.

  9. Calibration through on-line monitoring of instruments channels

    International Nuclear Information System (INIS)

    James, R.W.

    1996-01-01

    Plant technical specifications require periodic calibration of instrument channels, and this has traditionally meant calibration at fixed time intervals for nearly all instruments. Experience has shown that unnecessarily frequent calibrations reduce channel availability and reliability, impact outage durations, and increase maintenance costs. An alternative approach to satisfying existing requirements for periodic calibration consists of on-line monitoring and quantitative comparison of instrument channels during operation to identify instrument degradation and failure. A Utility Working Group has been formed by EPRI to support the technical activities necessary to achieve generic NRC acceptance of on-line monitoring of redundant instrument channels as a basis for determining when to perform calibrations. A topical report proposing NRC acceptance of this approach was submitted in August 1995, and the Working Group is currently resolving NRC technical questions. This paper describes the proposed approach and the current status of the topical report with regard to NRC review. While these activities will not preclude utilities from continuing to use existing calibration approaches, successful acceptance of this performance-based approach will allow utilities to substantially reduce the number of calibrations which are performed. Concurrent benefits will include reduced I ampersand C impact on outage durations and improved sensitivity to instrument channel performance

  10. On-line optimal control improves gas processing

    International Nuclear Information System (INIS)

    Berkowitz, P.N.; Papadopoulos, M.N.

    1992-01-01

    This paper reports that the authors' companies jointly funded the first phase of a gas processing liquids optimization project that has the specific purposes to: Improve the return of processing natural gas liquids, Develop sets of control algorithms, Make available a low-cost solution suitable for small to medium-sized gas processing plants, Test and demonstrate the feasibility of line control. The ARCO Willard CO 2 gas recovery processing plant was chosen as the initial test site to demonstrate the application of multivariable on-line optimal control. One objective of this project is to support an R ampersand D effort to provide a standardized solution to the various types of gas processing plants in the U.S. Processes involved in these gas plants include cryogenic separations, demethanization, lean oil absorption, fractionation and gas treating. Next, the proposed solutions had to be simple yet comprehensive enough to allow an operator to maintain product specifications while operating over a wide range of gas input flow and composition. This had to be a supervisors system that remained on-line more than 95% of the time, and achieved reduced plant operating variability and improved variable cost control. It took more than a year to study various gas processes and to develop a control approach before a real application was finally exercised. An initial process for C 2 and CO 2 recoveries was chosen

  11. Amdel on-line analyser at Rooiberg Tin Limited

    International Nuclear Information System (INIS)

    Owen, T.V.

    1987-01-01

    An Amdel on line analysis system was installed on the 'A' mine tin flotation plant at Rooiberg in April 1984. The motivation for the installation was made on account of the large variations in the feed grade to the plant and the resulting need for rapid operational adjustments to control concentrate grades thereby maximising the financial returns. An 'on-line' analyser system presented itself as a suitable alternative to the existing control method of smaller laboratory x-ray fluorescence analysers. On the system as installed at Rooiberg, two probes were fitted in each analysis zone, viz a density probe using high energy gamma radiation from a Cesium 127 source and a specific element absorption probe using low energy gamma radiation from a Americium 241 source. The signals as received from the probes are fed to a line receiver unit in the control room where a micro computer is doing the processing and prints out the information as required. Several advantages of this type of installation were gained at Rooiberg Tin Limited

  12. On-line Social Interactions and Executive Functions

    Directory of Open Access Journals (Sweden)

    Oscar eYbarra

    2012-04-01

    Full Text Available A successful social interaction requires fast, on-line, and active construction of an ever-changing mental-model of another’s person beliefs, expectations, emotions, and desires. It also requires the ability to inhibit inappropriate behaviors, problem-solve, take-turns, and pursue goals in a distraction-rich environment. All these tasks rely on executive functions (EF—working memory, attention/cognitive control, and inhibition. Executive functioning has long been viewed as relatively static. However, starting with recent reports of successful cognitive interventions, this view is changing and now EFs are seen as much more open to both short and long term training, warm-up, and exhaustion effects. Some of the most intriguing evidence comes from research showing how social interaction enhances performance on standard EF tests. Interestingly, the latest research indicates these EF benefits are selectively conferred by certain on-line, dynamic social interactions, which require participants to engage with another person and actively construct the model of their mind. We review this literature and highlight its connection with evolutionary and cultural theories emphasizing links between intelligence and social life.

  13. Project development and commercialisation of on-line analysis systems

    International Nuclear Information System (INIS)

    Watt, J.S.

    2000-01-01

    A project team first in the Australian Atomic Energy Commission (AAEC) and since 1982 in CSIRO has developed many on-line analysis systems for the mineral and energy industries. The development of these projects, usually lasting 7-10 years, has followed a common pattern of laboratory R and D, field trials, commercialisation and technology transfer. This successful pattern is illustrated using examples of the development of systems for the on-line analysis of mineral slurries, for determination of the ash content of coal on conveyors, and for determination of the flow rates of oil, water and gas in pipelines. The first two systems, licensed to Australian companies, are used world-wide. They are now the market leaders for radioisotope gauges in their application field. The third, the multiphase flow meter, was licensed in 1997 to an international company. This meter has even greater potential than the other two systems for economic benefit from its use and for numbers of installations. (author)

  14. Increased Cortical Thickness in Professional On-Line Gamers

    Science.gov (United States)

    Hyun, Gi Jung; Shin, Yong Wook; Kim, Bung-Nyun; Cheong, Jae Hoon; Jin, Seong Nam

    2013-01-01

    Objective The bulk of recent studies have tested whether video games change the brain in terms of activity and cortical volume. However, such studies are limited by several factors including cross-sectional comparisons, co-morbidity, and short-term follow-up periods. In the present study, we hypothesized that cognitive flexibility and the volume of brain cortex would be correlated with the career length of on-line pro-gamers. Methods High-resolution magnetic resonance scans were acquired in twenty-three pro-gamers recruited from StarCraft pro-game teams. We measured cortical thickness in each individual using FreeSurfer and the cortical thickness was correlated with the career length and the performance of the pro-gamers. Results Career length was positively correlated with cortical thickness in three brain regions: right superior frontal gyrus, right superior parietal gyrus, and right precentral gyrus. Additionally, increased cortical thickness in the prefrontal cortex was correlated with winning rates of the pro-game league. Increased cortical thickness in the prefrontal and parietal cortices was also associated with higher performance of Wisconsin Card Sorting Test. Conclusion Our results suggest that in individuals without pathologic conditions, regular, long-term playing of on-line games is associated with volume changes in the prefrontal and parietal cortices, which are associated with cognitive flexibility. PMID:24474988

  15. BOOK REVIEW: ON-LINE EDUCATION: AN EMANCIPATING VISION

    Directory of Open Access Journals (Sweden)

    Reviewed by Dr. Abdullah KUZU

    2006-04-01

    Full Text Available ON-LINE EDUCATION: AN EMANCIPATING VISION Written by Margarita Victoria Gomez Publisher: Cortez Editora ISBN 85-249-1062-3 São Paulo, Brazil, July 2004. Reviewed by Ricardo Romo TORRES Manuel Moreno Castaneda Maria del Sol Orozco Aguirre Universidad de Guadalajara Virtual MEXICO http://www.udgvirtual.udg.mx "On-line Education " is a book that meets the challenge to present itself as an unfinished text. In addition to demanding an active participation of the reader, it requires a predisposition to complete it through an also inconclusive dialogue. Among its goals we can find the search for education networks that remain under constant reconstruction, maintaining the emancipative vision as an imperative for the reconfiguration, as a constituted tissue for the scaffolding of subjects who impress,imagine, think and have a will. The unfinished part is presented in the following paragraph: "Similar to Babel according to Borges, knowledge is the product of a hazard in which fiction is the universe and where, out of fear of its multiple combinations, individual texts constitute an unfinished tale. In this labyrinth-shaped universe, the mirror and the recurrence do not allow finding the way out" page 134. The sense of being of man within a planetary community is framed by the ontological condition of conclusiveness; the requirement of being more, however, as well. This more is guided by the need for dialogue with others in terms of the opening and maintaining an unconcluded dialogue. The idea of a web or network leads to an articulating demand within the context of the category of wholeness. Based on this category, we will be able to present a reticulum of concepts where we can find included the web, subjectivity, identity, experience, mediation and, of course, digital literacy. This reticulum results in a concept of identified education with a condensed arrival point to something that the author defines as 'the pedagogy of virtuality'. The author is

  16. Preparation and Evaluation of Orodispersible Tablets Containing ...

    African Journals Online (AJOL)

    wetting and disintegration times, water absorption, and in vtro dissolution. Results: Increase in ... reagent were purchased from Sigma-Aldrich (St. Louis, MO). ... pressure and the resultant solid dispersions were collected [10]. ... were prepared. Preweighed amount of the ..... It is an ideal choice for low calorie and diabetic ...

  17. The development of on-line thermal performance monitors in Nuclear Electric Company's stations

    International Nuclear Information System (INIS)

    Conner, A.S.

    1992-01-01

    The paper examines the economic benefits of using on-line monitoring techniques in assisting Station Staff with the task of optimising the efficient use of reactor fuel. The role of thermal performance monitoring for detecting changes in plant condition is also examined and the way in which the data can be used by engineers to assist with the preparation of operating and maintenance programmes. To enable genuine gradual changes in plant performance to be detected when operating against a background of changing plant signal accuracy conditions, plant transducers have to be calibrated on a regular basis. This can be both costly and labour intensive. To reduce this requirement for regular calibrations, an automatic software signal verification program has been developed for use in on-line monitoring schemes. It forms part of the total unit performance calculation package and uses a whole plant model to verify plant signals. All plant signals used to calculate unit heat rate are verified typically every 15 minutes with signals going outside predetermined limits being automatically reported to the user. The program is interactive allowing the user to interrogate the condition of the signal, with respect to both its error magnitude and rate of drift outside signal limits. The program runs in real time mode on a Workstation connected directly to the plant

  18. Mössbauer spectroscopy research of interaction of alumosilicic reagent and iron dissolved in water

    International Nuclear Information System (INIS)

    Feklistov, D Y; Filippov, V P; Kurchatov, I M; Laguntsov, N I; Salomasov, V A; Permyakov, Yu V

    2016-01-01

    The aim of this work is to reveal the results of alumosilicic reagent interaction with iron compounds contained in the water. This reagent is simultaneously coagulant-flocculant and adsorbent. The iron atoms state is studied in the reagent and in reacted sediment. The valence state of iron atoms are determined in the reagents and sediments. The existence of iron containing superparamagnetic particles in the sediment is shown. (paper)

  19. On-line determination of moisture in coal and coke

    International Nuclear Information System (INIS)

    Cutmore, N.G.; Sowerby, B.D.

    1987-01-01

    The CSIRO Division of Mineral Engineering is developing various techniques for the on-line determination of moisture in coal and coke, and some instruments are now commercially available. These techniques permit accurate and rapid determination of moisture in materials directly on conveyor belts or in bins. The most promising techniques for direct on-belt measurement of moisture in coal are capacitance and microwave transmission. A non-contacting under-belt capacitance and gamma-ray backscatter technique has determined moisture in coal to better than 0.5 wt% in field tests. CSIRO is developing a fast neutron and gamma-ray transmission technique, which is proving very accurate in laboratory tests. This technique overcomes many of the limitations of thermal neutrons moisture gauges

  20. On-line monitoring system for utility boiler diagnostics

    International Nuclear Information System (INIS)

    Radovanovic, P.M.; Afgan, N.H.; Caralho, M.G.

    1997-01-01

    The paper deals with the new developed modular type Monitoring System for Utility Boiler Diagnostics. Each module is intended to assess the specific process and can be used as a stand alone application. Four modules are developed, namely: LTC - module for the on-line monitoring of parameters related to the life-time consumption of selected boiler components; TRD - module for the tube rupture detection by the position and working fluid Ieakage quantity; FAM - module for the boiler surfaces fouling (slagging) assessment and FLAP - module for visualization of the boiler furnace flame position. All four modules are tested on respective pilot plants built oil the 200 and 300 MWe utility boilers. Monitoring System is commercially available and can be realized in any combination of its modules depending on demands induced by the operational problems of specific boiler. Further development of Monitoring System is performed in accordance with the respective EU project on development of Boiler Expert System. (Author)

  1. On-line Certification for All: The PINVOX Algorithm

    Directory of Open Access Journals (Sweden)

    E Canessa

    2012-09-01

    Full Text Available A protoype algorithm: PINVOX (“Personal Identification Number by Voice" for on-line certification is introduced to guarantee that scholars have followed, i.e., listened and watched, a complete recorded lecture with the option of earning a certificate or diploma of completion after remotely attending courses. It is based on the injection of unique, randomly selected and pre-recorded integer numbers (or single letters or words within the audio trace of a video stream at places where silence is automatically detected. The certificate of completion or “virtual attendance” is generated on-the-fly after the successful identification of the embedded PINVOX code by a video viewer student.

  2. On-line control of the nonlinear dynamics for synchrotrons

    Science.gov (United States)

    Bengtsson, J.; Martin, I. P. S.; Rowland, J. H.; Bartolini, R.

    2015-07-01

    We propose a simple approach to the on-line control of the nonlinear dynamics in storage rings, based on compensation of the nonlinear resonance driving terms using beam losses as the main indicator of the strength of a resonance. The correction scheme is built on the analysis of the resonance driving terms in first perturbative order and on the possibility of using independent power supplies in the sextupole magnets, which is nowadays present in many synchrotron light sources. Such freedom allows the definition of "smart sextupole knobs" attacking each resonance separately. The compensation scheme has been tested at the Diamond light source and proved to be effective in opening up the betatron tune space, resonance free, available to the electron beam and to improve the beam lifetime.

  3. On-line control of the nonlinear dynamics for synchrotrons

    Directory of Open Access Journals (Sweden)

    J. Bengtsson

    2015-07-01

    Full Text Available We propose a simple approach to the on-line control of the nonlinear dynamics in storage rings, based on compensation of the nonlinear resonance driving terms using beam losses as the main indicator of the strength of a resonance. The correction scheme is built on the analysis of the resonance driving terms in first perturbative order and on the possibility of using independent power supplies in the sextupole magnets, which is nowadays present in many synchrotron light sources. Such freedom allows the definition of “smart sextupole knobs” attacking each resonance separately. The compensation scheme has been tested at the Diamond light source and proved to be effective in opening up the betatron tune space, resonance free, available to the electron beam and to improve the beam lifetime.

  4. On-line monitoring system for I-131 manufacturing labs

    International Nuclear Information System (INIS)

    Osovizky, A.; Malamud, Y.; Paran, Y.; Tal, N.; Turgeman, S.; Weinstein, M.

    1997-01-01

    An on-line monitoring and safety system has been installed in a lab for manufacturing 1-131 capsules for nuclear medicine use. Production of up to 100mCi batches is performed in shielded glove boxes. The safety system is based on a unique, 'Medi SMARTS' system (Medical Survey Mapping Automatic Radiation Tracing System), that collects continuously the radiation measurements for processing, display, and storage for future retrieval. Radiation is measured by GM tubes, data is transferred to a data processing unit, and then via a RS-485 communication line to a computer. In addition to the operational advantages and radiation levels storage, the system is being evaluated for the purpose of identifying risky stages in the process. (authors)

  5. Issues for Bringing Electron Beam Irradiators On-Line

    International Nuclear Information System (INIS)

    Kaye, R.J.; Turman, B.N.

    1999-01-01

    Irradiation of red meat and poultry has been approved by the U.S. FDA, and the U.S. Department of Agriculture's rule for processing red meat is out for comment. Looking beyond the current issues of packaging materials, labeling, and consumer acceptance, this paper reviews the next step of implementation and how to remove, or at least reduce, the barriers to utilization. Polls of the user community identified their requirements for electron beam or x-ray processing of meat or poultry and their concerns about implementation for on-line processing. These needs and issues are compared to the capabilities of the accelerator industry. The critical issues of beam utilization and dose uniformity, factors affecting floor space requirements, and treatment costs are examined

  6. On-line fatigue monitoring system for reactor pressure vessel

    International Nuclear Information System (INIS)

    Tokunaga, K.; Sakai, A.; Aoki, T.; Ranganath, S.; Stevens, G.L.

    1994-01-01

    A workstation-based, on-line fatigue monitoring system for tracking fatigue usage applied to an operating boiling water reactor (BWR), Tsuruga Unit-1, is described. The system uses the influence function approach and determines component stresses using temperature, pressure, and flow rate data that are made available via signal taps from previously existing plant sensors. Using plant unique influence functions developed specifically for the feedwater nozzle location, the system calculates stresses as a function of time and computed fatigue usage. The analysis method used to compute fatigue usage complies with MITI Code Notification No.501. Fatigue usage results for an entire fuel cycle are presented and compared to assumed design basis events to confirm that actual plant thermal duty is significantly less severe than originally estimated in the design basis stress report. As a result, the system provides the technical basis to more accurately evaluate actual reactor conditions as well as the justification for plant life extension. (author)

  7. On-line fatigue monitoring and probabilistic assessment of margins

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, I. [Electricite de France, 93 - Saint-Denis (France). Direction des Etudes et Recherches; Morilhat, P. [Electricite de France, 93 - Saint-Denis (France). Direction des Etudes et Recherches

    1995-01-01

    An on-line computer-aided system has been developed by Electricite de France, the French utility, for fatigue monitoring of critical locations in the nuclear steam supply system. This tool, called a fatigue meter, includes as input data plant parameters and is based on some conservative assumptions at several steps of the damage assessment (thermal boundary conditions, stress computation,..). In this paper we present recent developments performed towards a better assessment of margins involved in the complete analysis. The methodology is illustrated with an example showing the influence of uncertainty in plant parameters on the final stress computed at a pressurized water reactor 900MW unit pressurizer surge line nozzle. A second example is shown to illustrate the possibility of defining some transient archetypes. ((orig.)).

  8. On-line Monitoring of Instrumentation in Research Reactors

    International Nuclear Information System (INIS)

    2017-12-01

    This publication is the result of a benchmarking effort undertaken under the IAEA coordinated research project on improved instrumentation and control (I&C) maintenance techniques for research reactors. It lays the foundation for implementation of on-line monitoring (OLM) techniques and establishment of the validity of those for improved maintenance practices in research reactors for a number of applications such as change to condition based calibration, performance monitoring of process instrumentation systems, detection of process anomalies and to distinguish between process problems/effects and instrumentation/sensor issues. The techniques and guidance embodied in this publication will serve the research reactor community in providing the technical foundation for implementation of OLM techniques. It is intended to be used by Member States to implement I&C maintenance and to improve performance of research reactors.

  9. On-line control of nuclear fuel reprocessing

    International Nuclear Information System (INIS)

    Parus, I.; Kierzek, J.; Zoltowski, T.

    1977-01-01

    The development trends in the field of chemical processes control and the present state of the development of continuous composition analysers has been described. On this background the peculiarities of on-line control methods for spent nuclear fuel reprocessing have been discussed. The measuring methods for direct and indirect determination of chemical composition and nuclear safety are reviewed in detail. The review comprises such methods as: measurement of α, γ and neutron radiation emitted both by nuclides present in technological solutions and using external sources of different radiation, X-ray fluorescence, measurements of physicochemical parameters connected with the composition (pH, density, electrical conductivity), polarography and spectrophotometry. At the end of this review some new trends in process control based on dynamic process models have been presented. (author)

  10. The Task Manager for the LHCb On-Line Farm

    CERN Document Server

    Bonifazi, F; Carbone, A; Galli, D; Gregori, D; Marconi, U; Peco, G; Vagnoni, V

    2004-01-01

    The Task Manager is a utility to start, stop and list processes on the on-line farm. Each process started by the Task Manager has a string environment variable set, named UTGID (User defined unique Thread Group Identifier) which allows to identify the process. The Task Manager uses the UTGID to list the running processes and to identify the processes to be stopped. It has also the ability to start a process using a particular user name and to set the scheduler type and the priority for the process itself. The Task Manager package includes a Linux DIM server (tmSrv), four Linux command line DIM clients (tmStart, tmLs, tmKill and tmStop) and a JCOP (Joint Control Project) PVSS client.

  11. On-line Corrosion Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Richter, Sonja; Thorarinsdottir, R.I.; Hilbert, Lisbeth Rischel

    2005-01-01

    The corrosion control in district heating systems is today performed primarily with control of the water quality. The corrosion rate is kept low by assuring low dissolved oxygen concentration, high pH and low conductivity. Corrosion failures can occur, e.g. as a result of unknown oxygen ingress, ......, precipitation of deposits or crevices. The authors describe methods used for on-line monitoring of corrosion, cover the complications and the main results of a Nordic project.......The corrosion control in district heating systems is today performed primarily with control of the water quality. The corrosion rate is kept low by assuring low dissolved oxygen concentration, high pH and low conductivity. Corrosion failures can occur, e.g. as a result of unknown oxygen ingress...

  12. NOASYS, a system for on-line noise analysis

    International Nuclear Information System (INIS)

    Massier, H.

    1978-07-01

    This report describes NOASYS, a versatile NOise Analysis SYStem for digital on-line signal processing. The system based on a minicomputer, was originally developed for the analysis of noise signals from nuclear reactors. NOASYS computes various statistical functions e.g. cross- und auto-correlation functions and power spectral densities resp., which may be used for reactor diagnosis and malfunction detection. The system processes up to 16 analog signals with a maximum sampling frequency of 100 kcps (1 channel). The processing of the sampled data is done by a number of software tasks, which may be called from a teletype or linked together for specific measuring programs. The standard configuration contains the often used processing routines e.g. Fast Fourier Transform, complex multiplication, summation etc. In addition NOASYS may be extended by users own tasks (in Assembler or Fortran) to fit for specific applications. (orig.) 891 HP [de

  13. On-line efficiency optimization of a synchronous reluctance motor

    Energy Technology Data Exchange (ETDEWEB)

    Lubin, Thierry; Razik, Hubert; Rezzoug, Abderrezak [Groupe de Recherche en Electrotechnique et Electronique de Nancy, GREEN, CNRS-UMR 7037, Universite Henri Poincare, BP 239, 54506 Vandoeuvre-les-Nancy Cedex (France)

    2007-04-15

    This paper deals with an on-line optimum-efficiency control of a synchronous reluctance motor drive. The input power minimization control is implemented with a search controller using Fibonacci search algorithm. It searches the optimal reference value of the d-axis stator current for which the input power is minimum. The input power is calculated from the measured dc-bus current and dc-bus voltage of the inverter. A rotor-oriented vector control of the synchronous reluctance machine with the optimization efficiency controller is achieved with a DSP board (TMS302C31). Experimental results are presented to validate the proposed control methods. It is shown that stability problems can appear during the search process. (author)

  14. Development of on-line monitoring system using smart material

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Kyung; Lee, Sang Pill; Park, Yi Hyun [Dongeui Univ., Busan (Korea, Republic of); Park, Young Chul [Donga Univ., Busan (Korea, Republic of)

    2003-07-01

    A hot press method was used to create the optimal fabrication condition for a Shape Memory Alloy(SMA) composite. The bonding strength between the matrix and the reinforcement within the SMA composite by the hot press method was more increased by cold rolling. In this study, the objective was to develop an on-line monitoring system in order to prevent the crack initiation and propagation by shape memory effect in SMA composite. Shape memory effect was used to prevent the SMA composite from crack propagation. For this system an optimal AE parameter should be determined according to the degree of damage and crack initiation. When the SMA composite was heated by the plate heater attached at the composite, the propagating cracks could be controlled by the compressive force of SMA.

  15. Development of on-line monitoring system using smart material

    International Nuclear Information System (INIS)

    Lee, Jin Kyung; Lee, Sang Pill; Park, Yi Hyun; Park, Young Chul

    2003-01-01

    A hot press method was used to create the optimal fabrication condition for a Shape Memory Alloy(SMA) composite. The bonding strength between the matrix and the reinforcement within the SMA composite by the hot press method was more increased by cold rolling. In this study, the objective was to develop an on-line monitoring system in order to prevent the crack initiation and propagation by shape memory effect in SMA composite. Shape memory effect was used to prevent the SMA composite from crack propagation. For this system an optimal AE parameter should be determined according to the degree of damage and crack initiation. When the SMA composite was heated by the plate heater attached at the composite, the propagating cracks could be controlled by the compressive force of SMA

  16. Issues for Bringing Electron Beam Irradiators On-Line

    Energy Technology Data Exchange (ETDEWEB)

    Kaye, R.J.; Turman, B.N.

    1999-04-20

    Irradiation of red meat and poultry has been approved by the U.S. FDA, and the U.S. Department of Agriculture's rule for processing red meat is out for comment. Looking beyond the current issues of packaging materials, labeling, and consumer acceptance, this paper reviews the next step of implementation and how to remove, or at least reduce, the barriers to utilization. Polls of the user community identified their requirements for electron beam or x-ray processing of meat or poultry and their concerns about implementation for on-line processing. These needs and issues are compared to the capabilities of the accelerator industry. The critical issues of beam utilization and dose uniformity, factors affecting floor space requirements, and treatment costs are examined.

  17. Escapist Motives for Playing On-Line Games

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana

    2012-01-01

    Social games have become popular along with the tremendous growth of social networking sites, esp. Facebook. There is a gap in literature on what motivates people to play Facebook games. This paper studies social games usage behavior of students. We focus on escapist reasons, based on Warmelink...... of escapist motives for playing Facebook and other on-line games, we investigate how they are linked to demographic data such as: age, gender, place of origin, along with other social interactions patterns and social network usage behavior, current gaming status and an estimate of gaming time. According...... to our study, only 10% of respondents, who have started to play Facebook games, continued to play them. The most important motives for playing games is mundane breaking, the second reason is pleasure seeking, the third is stress relieving, and the least important is imagination conjuring....

  18. Configuration Database for BaBar On-line

    International Nuclear Information System (INIS)

    Salnikov, Andrei

    2003-01-01

    The configuration database is one of the vital systems in the BaBar on-line system. It provides services for the different parts of the data acquisition system and control system, which require run-time parameters. The original design and implementation of the configuration database played a significant role in the successful BaBar operations since the beginning of experiment. Recent additions to the design of the configuration database provide better means for the management of data and add new tools to simplify main configuration tasks. We describe the design of the configuration database, its implementation with the Objectivity/DB object-oriented database, and our experience collected during the years of operation

  19. 3rd Computer Science On-line Conference

    CERN Document Server

    Senkerik, Roman; Oplatkova, Zuzana; Silhavy, Petr; Prokopova, Zdenka

    2014-01-01

    This book is based on the research papers presented in the 3rd Computer Science On-line Conference 2014 (CSOC 2014).   The conference is intended to provide an international forum for discussions on the latest high-quality research results in all areas related to Computer Science. The topics addressed are the theoretical aspects and applications of Artificial Intelligences, Computer Science, Informatics and Software Engineering.   The authors provide new approaches and methods to real-world problems, and in particular, exploratory research that describes novel approaches in their field. Particular emphasis is laid on modern trends in selected fields of interest. New algorithms or methods in a variety of fields are also presented.   This book is divided into three sections and covers topics including Artificial Intelligence, Computer Science and Software Engineering. Each section consists of new theoretical contributions and applications which can be used for the further development of knowledge of everybod...

  20. On-line Ciphers and the Hash-CBC Constructions

    DEFF Research Database (Denmark)

    Bellare, M.; Boldyreva, A.; Knudsen, Lars Ramkilde

    2012-01-01

    We initiate a study of on-line ciphers. These are ciphers that can take input plaintexts of large and varying lengths and will output the i th block of the ciphertext after having processed only the first i blocks of the plaintext. Such ciphers permit length-preserving encryption of a data stream...... with only a single pass through the data. We provide security definitions for this primitive and study its basic properties. We then provide attacks on some possible candidates, including CBC with fixed IV. We then provide two constructions, HCBC1 and HCBC2, based on a given block cipher E and a family...... of computationally AXU functions. HCBC1 is proven secure against chosen-plaintext attacks assuming that E is a PRP secure against chosen-plaintext attacks, while HCBC2 is proven secure against chosen-ciphertext attacks assuming that E is a PRP secure against chosen-ciphertext attacks....

  1. On-line defected fuel monitoring using GFP data

    International Nuclear Information System (INIS)

    Livingstone, S.; Lewis, B.J.

    2008-01-01

    This paper describes the initial development of an on-line defected fuel diagnostic tool. The tool is based on coolant activity, and uses a quantitative and qualitative approach from existing mechanistic fission product release models, and also empirical rules based on commercial and experimental experience. The model departs from the usual methodology of analyzing steady-state fission product coolant activities, and instead uses steady-state fission product release rates calculated from the transient coolant activity data. An example of real-time defected fuel analysis work is presented using a prototype of this tool with station data. The model is in an early developmental stage, and this paper demonstrates the promising potential of this technique. (author)

  2. An on-line advanced plant simulator (OLAPS)

    International Nuclear Information System (INIS)

    Samuels, J.W.

    1989-01-01

    A PC based on-line advanced plant simulator (OLAPS) for high quality simulations of Portland General Electric's Trojan Nuclear Facility is presented. OLAPS is designed to simulate the thermal-hydraulics of the primary system including core, steam generators, pumps, piping and pressurizer. The simulations are based on a five equation model that has two mass equations, two energy equations, two energy equations, and one momentum equation with a drift flux model to provide closure. A regionwise point reactor kinetics model is used to model the neutron kinetics in the core. The conservation equations, constitutive models and the numerical methods used to solve them are described. OLAPS results are compared with data from chapter 15 of the Trojan Nuclear Facility's final safety analysis report

  3. The Monitor System for the LHCb on-line farm

    CERN Document Server

    Bonifazi, F; Carbone, A; Galli, D; Gregori, D; Marconi, U; Peco, G; Vagnoni, V

    2005-01-01

    The aim of the LHCb on-line farm Monitor System is to keep under control all the working indicators which are relevant for the farm operation, and to set the appropriate alarms whenever an error or a critical condition comes up. Since the most stressing tasks of the farm are the data transfer and processing, relevant indicators includes the CPU and the memory load of the system, the network interface and the TCP/IP stack parameters, the rates of the interrupts raised by the network interface card and the detailed status of the running processes. The monitoring of computers’ physical conditions (temperatures, fan speeds and motherboard voltages) are the subject of a separate technical note, since they are accessed in a different way, by using the IPMI protocol.

  4. On-line monitoring of main coolant pump seals

    International Nuclear Information System (INIS)

    Stevens, D.M.; Spencer, J.W.; Morris, D.J.; Glass, S.W.; Sommerfield, G.A.; Harrison, D.

    1984-06-01

    The Babcock and Wilcox Company has developed and implemented a Reactor Coolant Pump Monitoring and Diagnostic System (RCPM and DS). The system has been installed at Toledo Edison Company's Davis-Besse Nuclear Power Station Unit 1. The RCPM and PS continuously monitors a number of indicators of pump performance and notifies the plant operator of out-of-tolerance conditions or pump performance trending toward out-of-tolerance conditions. Pump seal parameters being monitored include pump internal pressures, temperatures, and flow rates. Rotordynamic performanvce and plant operating conditions are also measured with a variety of dynamic sensors. This paper describes the implementation of the system and the results of on-line monitoring of four RC pumps

  5. PHEBUS on-line aerosol monitor development test program

    International Nuclear Information System (INIS)

    Sprenger, M.H.; Pentecost, C.G.

    1992-03-01

    EG ampersand G Idaho, Inc. developed an on-line aerosol monitor (OLAM) for the French PHEBUS Fission Product Project. Part of the development was to manufacture and test an OLAM prototype. This report presents the results of the testing which determined the mechanical integrity of the monitor at operating temperature and pressure and performed a preliminary test of the optical system. A series of twenty different tests was conducted during the prototype testing sequence. Since no leaks were detected, the OLAM demonstrated that it could provide a pressure boundary at required test conditions. The optical and electrical system also proved its integrity by exceeding the design requirement of less than 105 optical signal drift during an actual two-hour test sequence

  6. On line isotopic separator test benches at GANIL

    International Nuclear Information System (INIS)

    Anne, R.; Bru, B.; Joubert, A.; Leroy, R.; Obert, J.; Putaux, J.C.; Liang, C.F.; Paris, P.; Orr, N.; Steckmeyer, J.C.

    1993-01-01

    A first version of isotopic separator on line test bench has been built in order to test the feasibility of the production of radioactive species from 96 MeV/u of 20 Ne impinging a thick target of MgO. This test bench was equipped with a very compact ECR ion source (Nanogan) entirely made from permanent magnets and operating at 10 Ghz. 18 Ne 2,4+ ; 19N e 1,2,3,4+ and 23,24 Ne 1+ has been produced and ionized. A new more performing separator (SIRa) allowing the use of different types of ion sources will be completed by the end of 1993. (author) 4 refs., 4 figs., 1 tab

  7. Kalman filtering applied to a reagent feed system

    International Nuclear Information System (INIS)

    Griffin, C.D.; Croson, D.V.; Feeley, J.J.

    1988-01-01

    Using a Kalman filter solves a troublesome measurement noise problem and, at the same time, improves nuclear safety by detecting leaks to the process' feed tanks. To demonstrate how this technology of optimal estimation can be exploited, this article presents a systematic plan and example of how a Kalman filter was proven in industrial use on a reagent analyzer. A process to recycle uranium from spent fuel elements uses a reagent stream containing boron to dissolve the fuel. The boron is the neutron poison that prevents a nuclear chain reaction during the uranium dissolution. The purpose of the Kalman filter for this system is to reduce the uncertainty in the boron concentration measurement. The filter also provides incipient fault detection by estimating the unmeasured state of any unpoisoned solution, which would dilute the boron solution, entering the feed vessel

  8. Semi-continuous on-line uranium ore analyzer

    International Nuclear Information System (INIS)

    Campbell, P.; Gurdy, E.M.; Hatchowski, L.

    1984-01-01

    The efficient process control of a uranium mill and its associated mining operation requires a nearly continuous knowledge of the uranium concentration in the ore. Generally, the approach is to use laboratory assays of grab samples from the mill feed belt. In some cases, elaborate and expensive systems have been used to ensure random sampling, but even with these systems, mass-balance discrepancies still exist. There is a requirement for an on-line instrument that can give a prompt, accurate analysis of a large portion of the feed stock. The authors have recently evaluated a laboratory system that achieves these goals using neutron activation and delayed neutron counting. The development of the on-line uranium ore analyzer is a consequence of previous work done at the Whiteshell Nuclear Research Establishment (WNRE) (Campbell et al., 1978 and 1981), and is based on the emission of delayed neutrons after the neutron irradiation of fissionable materials. The mechanism of delayed neutron emission has been described (Keepin, 1965), but briefly is as follows. The fission fragments resulting from irradiation are in an excited state. Certain of these delayed fission products, precursors, decay to a more stable state by the emission of a delayed neutron. The delayed neutrons can be divided into six groups with effective half-lives ranging from 0.2-55 sec. It is important to note that more than 50% of the delayed neutrons are emitted within the first 6 sec after irradiation; this has an influence on the design of the analysis instrument

  9. PHENIX On-Line Distributed Computing System Architecture

    International Nuclear Information System (INIS)

    Desmond, Edmond; Haggerty, John; Kehayias, Hyon Joo; Purschke, Martin L.; Witzig, Chris; Kozlowski, Thomas

    1997-01-01

    PHENIX is one of the two large experiments at the Relativistic Heavy Ion Collider (RHIC) currently under construction at Brookhaven National Laboratory. The detector consists of 11 sub-detectors, that are further subdivided into 29 units (''granules'') that can be operated independently, which includes simultaneous data taking with independent data streams and independent triggers. The detector has 250,000 channels and is read out by front end modules, where the data is buffered in a pipeline while awaiting the level trigger decision. Zero suppression and calibration is done after the level accept in custom built data collection modules (DCMs) with DSPs before the data is sent to an event builder (design throughput of 2 Gb/sec) and higher level triggers. The On-line Computing Systems Group (ONCS) has two responsibilities. Firstly it is responsible for receiving the data from the event builder, routing it through a network of workstations to consumer processes and archiving it at a data rate of 20 MB/sec. Secondly it is also responsible for the overall configuration, control and operation of the detector and data acquisition chain, which comprises the software integration for several thousand custom built hardware modules. The software must furthermore support the independent operation of the above mentioned granules, which includes the coordination of processes that run in 60-100 VME processors and workstations. ONOS has adapted the Shlaer- Mellor Object Oriented Methodology for the design of the top layer software. CORBA is used as communication layer between the distributed objects, which are implemented as asynchronous finite state machines. We will give an overview of the PHENIX online system with the main focus on the system architecture, software components and integration tasks of the On-line Computing group ONCS and report on the status of the current prototypes

  10. Progress and performance of on-line analyzers of coal

    International Nuclear Information System (INIS)

    Spencer, C.M.; Brown, D.R.; Gozani, T.; Bozorgmanesh, H.; Bernatowicz, H.; Tassicker, O.J.; Karlson, F.

    1982-01-01

    This paper describes the past year's progress in the laboratory testing of the most comprehensive Nucoalyzer, the CONAC, and the performance of a Nucoalyzer-Sulfurmeter in special field tests. Previous papers and presentations provide more detailed background information. The near real-time analysis provided by a Nucoalyzer can be used in a variety of strategies to optimize efficiency of coal use. Nucoalyzers can be used to monitor coal deliveries and achieve uniformity in coal storage and recovery. In a coal cleaning plant, on-line analysis with a Nucoalyzer can lead to optimum Btu recovery while meeting specifications for the washed coal. A Nucoalyzer can monitor the blending of different coals to maintain a key cosntituent such as sulfur below a specified level, or can predict sulfur dioxide emissions, allowing feed-forward control to gas scrubbers and precipitators. Variability in coal feed to the boiler can lead to gross changes in thermodynamic efficiency in combustion. In addition, fouling and slagging incidents due to poor coal quality cause costly boiler shutdowns and maintenance. Nucoalyzer monitoring of key constituents and Btu in the coal feed allows operators to adjust boiler parameters for increased efficiency. To summarize, the primary advantages of Nucoalyzers relate to their ability to quickly identify changes in coal composition so that adjustments can be made in a timely manner to accommodate these changes in the process being monitored. Nucoalyzers are the only instruments available that can monitor the coal (for ash, Btu, sulfur, etc.) on-line and provide real-time continuous results. One Nucoalyzer is already working in the field, and by the time of the next Symposium we will have had performance reports on two more

  11. On-line chemical sensors for applications in fast reactors

    International Nuclear Information System (INIS)

    Jayaraman, V.

    2015-01-01

    Hydrogen sensors are essential components of fast reactor sodium circuits. These sensors are needed in fast reactors for the immediate detection of any steam leak into sodium during reactor operation which can lead to failure of steam generator. Depending on the operating power of the reactor, sodium-water reaction results in either an increase in dissolved hydrogen level in sodium or an increase in hydrogen content of argon cover gas used above sodium coolant. Hence, on-line monitoring of hydrogen continuously in sodium and cover circuits helps in detection of any steam leak. In the event of accidental leak of high temperature sodium, it reacts with oxygen and moisture in air leading to sodium fires. These fires produce sodium aerosol containing oxides of sodium (Na 2 O and Na 2 O 2 ) and NaOH. For early detection of sodium fires, sensor systems based on sodium ionization detector, pH measurement and modulation of conductivity of graphite films are known in the literature. This presentation deals with the development of on-line sensors for these two applications. A diffusion based sensor using a thin walled nickel coil at 773 K and a sensitive thermal conductivity detector (TCD) has been developed for monitoring hydrogen levels in argon cover gas. This sensor has a lower detection limit of 30 ppm of hydrogen in argon. To extend the detection limit of the sensor, a surface conductivity based sensor has been developed which makes use of a thin film of semi-conducting tin oxide. Integration of this sensor with the TCD, can extend the lower detection limit to 2 ppm of hydrogen in cover gas. Electrochemical sensor based on sodium-beta-alumina has been designed, fabricated and its performance in laboratory and industrial environment was evaluated. This paper presents the logical development of these sensors highlighting their merits and limitations

  12. Review of Worcestershire On-line Fabric Type Series website

    Directory of Open Access Journals (Sweden)

    Beverley Nenk

    2003-06-01

    Full Text Available The study of archaeological ceramics is advanced through the creation and development of regional and national pottery type-series, which contain samples of each type of pottery identified from a particular area or region. Pottery researchers working in any period, from prehistoric to post-medieval, require access to such type-series, and to their associated data, in order to be able to advance the identification of all types of pottery, not only those types produced in the local area, but those produced in surrounding regions, as well as those imported from abroad. The publication of such type-series, as well as their accessibility to researchers, is essential if the information they contain is to be disseminated. The development of the Worcestershire On-Line Fabric Type Series is the first stage in a remarkable project designed to make the complete fabric and form type series for Worcestershire ceramics accessible on the internet. As part of the Historic Environment Record for Worcestershire, formerly the Sites and Monuments Record, it is designed to improve access to finds and environmental data, with the aim of encouraging and facilitating research. Funded by Worcestershire County Council as part of its commitment to e-government, it is being developed by Worcestershire County Council Archaeology Service with OxfordArchDigital. It is one of a proposed series of on-line specialist resources (to include, for example, clay pipes, environmental archaeology, flint tools, historic buildings, which are also designed to stand alone as research tools. The ceramics website is the first part of Pottery in Perspective, a web-based project to provide information on the pottery used and made in Worcestershire from prehistory to c. 1900AD.

  13. Reporter-nanobody fusions (RANbodies) as versatile, small, sensitive immunohistochemical reagents.

    Science.gov (United States)

    Yamagata, Masahito; Sanes, Joshua R

    2018-02-27

    Sensitive and specific antibodies are essential for detecting molecules in cells and tissues. However, currently used polyclonal and monoclonal antibodies are often less specific than desired, difficult to produce, and available in limited quantities. A promising recent approach to circumvent these limitations is to employ chemically defined antigen-combining domains called "nanobodies," derived from single-chain camelid antibodies. Here, we used nanobodies to prepare sensitive unimolecular detection reagents by genetically fusing cDNAs encoding nanobodies to enzymatic or antigenic reporters. We call these fusions between a reporter and a nanobody "RANbodies." They can be used to localize epitopes and to amplify signals from fluorescent proteins. They can be generated and purified simply and in unlimited amounts and can be preserved safely and inexpensively in the form of DNA or digital sequence.

  14. Small-scale extraction and radioiodination of human hormones for the substitution of imported radioimmunoassay reagents

    International Nuclear Information System (INIS)

    Gimbo, E.K.; Ribela, M.T.C.P.; Borghi, V.C.; Schwarz, I.; Morganti, L.; Araujo, E.A.; Bartolini, P.

    1988-01-01

    The methods for national production of radioimmunoassay reagents to substitute imported kits of: highly purified unlabelled hormones for radioiodination; 125 I-labelled hormones; and specific high titre antisera are presented. The extraction and purification of human growth hormone (hGH) and human luteinizing hormone (hGH) were done from human pituitaries. The 125 I-labelled hormones are obtained by stoichiometric methods. The 125 I-hGH, 125 I-hLH, I-hTSH and 125 I- h calcitonin were prepared and tested in internal and external quality control, in comparison with imported products. The parameters such as: maximum binding to specific antiserum (Bo), nonspecific binding (NSB), mean effective dose (ED 50), sensitivity and accuracy were evaluated. (M.C.K.) [pt

  15. Identification of mimotopes of Mycobacterium leprae as potential diagnostic reagents

    Directory of Open Access Journals (Sweden)

    Alban Silvana M

    2013-01-01

    Full Text Available Abstract Background An early diagnostic test for detecting infection in leprosy is fundamental for reducing patients’ sequelae. The currently used lepromin is not adequate for disease diagnosis and, so far, no antigen to be used in intradermoreaction has proved to be sensitive and specific for that purpose. Aiming at identifying new reagents to be used in skin tests, candidate antigens were investigated. Methods Random peptide phage display libraries were screened by using antibodies from leprosy patients in order to identify peptides as diagnostic reagents. Results Seven different phage clones were identified using purified antibodies pooled from sera of leprosy patients. When the clones were tested with serum samples by ELISA, three of them, 5A, 6A and 1B, allowed detecting a larger number of leprosy patients when compared to controls. The corresponding peptides expressed by selected phage clones were chemically synthesized. A pilot study was undertaken to assess the use of peptides in skin tests. The intradermal challenge with peptides in animals previously sensitized with Mycobacterium leprae induced a delayed-type hypersensitivity with peptide 5A (2/5 and peptide 1B (1/5. In positive controls, there was a 3/5 reactivity for lepromin and a 4/5 reactivity of the sensitized animals with soluble extract of M. leprae. Conclusions The preliminary data suggest that may be possible to develop reagents with diagnostic potential based on peptide mimotopes selected by phage display using polyclonal human antibodies.

  16. The adsorption of chelating reagents on oxide minerals

    International Nuclear Information System (INIS)

    Bryson, M.A.W.

    1984-06-01

    This work constitutes a fundamental study of the interaction between chelating reagents and oxide minerals. The adsorption mechanisms have been elucidated for most of the systems generated by the oxides of copper(II) or iron(III) and chelating reagents octyl hydroxamate, N-phenylbenzohydroxamate, salicylaldoxime, 5-nitro-salicylaldoxime or 8-hydroxyquinoline. In order to better understand the adsorption process associated with copper(II) oxide, the oxide was recrystallized to produce a coarser material with a more uniform surface. This allowed the oxide surface to be viewed under the scanning electron microscope. A detailed investigation of the effect of the system variables; pH, conditioning period, concentration, temperature, surface area and dispersing reagent on the rate of precipitation of the copper chelate species of general form, Cu(chel) 2 , was made. In addition the chemical nature of the adsorbed species and the structural form of the precipitates were determined with the aid of infra-red spectroscopy and the scanning electron microscope. On the basis of these results a model has been formulated for the adsorption processes. The precipitation process was examined in more detail by the study of the adsorption of chelate on copper metal. Contact angle measurements of air bubbles on copper metal conditioned with chelate were related to the adsorption results in an attempt to isolate the optimum conditions for flotation of oxide minerals

  17. High Throughput Sample Preparation and Analysis for DNA Sequencing, PCR and Combinatorial Screening of Catalysis Based on Capillary Array Technique

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yonghua [Iowa State Univ., Ames, IA (United States)

    2000-01-01

    Sample preparation has been one of the major bottlenecks for many high throughput analyses. The purpose of this research was to develop new sample preparation and integration approach for DNA sequencing, PCR based DNA analysis and combinatorial screening of homogeneous catalysis based on multiplexed capillary electrophoresis with laser induced fluorescence or imaging UV absorption detection. The author first introduced a method to integrate the front-end tasks to DNA capillary-array sequencers. protocols for directly sequencing the plasmids from a single bacterial colony in fused-silica capillaries were developed. After the colony was picked, lysis was accomplished in situ in the plastic sample tube using either a thermocycler or heating block. Upon heating, the plasmids were released while chromsomal DNA and membrane proteins were denatured and precipitated to the bottom of the tube. After adding enzyme and Sanger reagents, the resulting solution was aspirated into the reaction capillaries by a syringe pump, and cycle sequencing was initiated. No deleterious effect upon the reaction efficiency, the on-line purification system, or the capillary electrophoresis separation was observed, even though the crude lysate was used as the template. Multiplexed on-line DNA sequencing data from 8 parallel channels allowed base calling up to 620 bp with an accuracy of 98%. The entire system can be automatically regenerated for repeated operation. For PCR based DNA analysis, they demonstrated that capillary electrophoresis with UV detection can be used for DNA analysis starting from clinical sample without purification. After PCR reaction using cheek cell, blood or HIV-1 gag DNA, the reaction mixtures was injected into the capillary either on-line or off-line by base stacking. The protocol was also applied to capillary array electrophoresis. The use of cheaper detection, and the elimination of purification of DNA sample before or after PCR reaction, will make this approach an

  18. Conversion of coal mine drainage ochre to water treatment reagent: Production, characterisation and application for P and Zn removal.

    Science.gov (United States)

    Sapsford, Devin; Santonastaso, Marco; Thorn, Peter; Kershaw, Steven

    2015-09-01

    Coal mine drainage ochre is a ferruginous precipitate that forms from mine water in impacted watercourses and during treatment. With thousands of tonnes per annum of such ochre arising from mine water treatment in the UK alone, management of these wastes is a substantive issue. This paper demonstrates that the ochre from both active and passive treatment of coal mine drainage can be transformed into an effective water treatment reagent by simple acid dissolution and that the reagent can be used for the removal of dissolved phosphorous from municipal wastewater and zinc from non-coal mine waters. Ochre is readily soluble in H2SO4 and HCl. Ochre is more soluble in HCl with solubilities of up to 100 g/L in 20% (w/w) HCl and 68 g/L in 10% (w/w) H2SO4. For four of the eight tested ochres solubility decreased in higher concentrations of H2SO4. Ochre compositional data demonstrate that the coal mine ochres tested are relatively free from problematic levels of elements seen by other authors from acid mine drainage-derived ochre. Comparison to British Standards for use of iron-based coagulants in drinking water treatment was used as an indicator of the acceptability of use of the ochre-derived reagents in terms of potentially problematic elements. The ochre-derived reagents were found to meet the 'Grade 3' specification, except for arsenic. Thus, for application in municipal wastewater and mine water treatment additional processing may not be required. There was little observed compositional difference between solutions prepared using H2SO4 or HCl. Ochre-derived reagents showed applicability for the removal of P and Zn with removals of up to 99% and 97% respectively measured for final pH 7-8, likely due to sorption/coprecipitation. Furthermore, the results demonstrate that applying a Fe dose in the form of liquid reagent leads to a better Fe:P and Fe:Zn removal ratio compared to ochre-based sorption media tested in the literature. Copyright © 2015 The Authors. Published by

  19. Preparation of PbSe nanoparticles by electron beam irradiation

    Indian Academy of Sciences (India)

    A novel method has been developed by electron beam irradiation to prepare PbSe nanoparticles. 2 MeV 10mA GJ-2-II electronic accelerator was used as radiation source. Nanocrystalline PbSe was prepared rapidly at room temperature under atmospheric pressure without any kind of toxic reagents. The structure and ...

  20. Inactivation of viable Ascaris eggs by reagents during enumeration.

    Science.gov (United States)

    Nelson, K L; Darby, J L

    2001-12-01

    Various reagents commonly used to enumerate viable helminth eggs from wastewater and sludge were evaluated for their potential to inactivate Ascaris eggs under typical laboratory conditions. Two methods were used to enumerate indigenous Ascaris eggs from sludge samples. All steps in the methods were the same except that in method I a phase extraction step with acid-alcohol (35% ethanol in 0.1 N H(2)SO(4)) and diethyl ether was used whereas in method II the extraction step was avoided by pouring the sample through a 38-microm-mesh stainless steel sieve that retained the eggs. The concentration of eggs and their viability were lower in the samples processed by method I than in the samples processed by method II by an average of 48 and 70%, respectively. A second set of experiments was performed using pure solutions of Ascaris suum eggs to elucidate the effect of the individual reagents and relevant combination of reagents on the eggs. The percentages of viable eggs in samples treated with acid-alcohol alone and in combination with diethyl ether or ethyl acetate were 52, 27, and 4%, respectively, whereas in the rest of the samples the viability was about 80%. Neither the acid nor the diethyl ether alone caused any decrease in egg viability. Thus, the observed inactivation was attributed primarily to the 35% ethanol content of the acid-alcohol solution. Inactivation of the eggs was prevented by limiting the direct exposure to the extraction reagents to 30 min and diluting the residual concentration of acid-alcohol in the sample by a factor of 100 before incubation. Also, the viability of the eggs was maintained if the acid-alcohol solution was replaced with an acetoacetic buffer. None of the reagents used for the flotation step of the sample cleaning procedure (ZnSO(4), MgSO(4), and NaCl) or during incubation (0.1 N H(2)SO(4) and 0.5% formalin) inactivated the Ascaris eggs under the conditions studied.

  1. Determination of anions with an on-line capillary electrophoresis method; Anionien on-line maeaeritys kapillaarielektroforeesilla - MPKT 10

    Energy Technology Data Exchange (ETDEWEB)

    Siren, H; Saerme, T; Kotiaho, T; Hiissa, T; Savolahti, P; Komppa, V [VTT Chemical Technology, Espoo (Finland)

    1999-12-31

    The aim of the study was to set-up an on-line capillary electrophoresis method for determination of anions in process waters of pulp and paper industry with exporting the results to the process control system of the mill. The quantification is important, since it will give information about the possible causes of precipitation. In recent years, the capillary electrophoresis (CE) due to its high separation efficiency has been shown as a method to take into consideration when analyzing chemical species ranging from small inorganic anions to different macromolecules. Many compounds are not easily detected in their native state, why analysis methods must be developed to improve their detection. Especially, small inorganic and organic anions which do not have chromophores are not sensitive enough for direct-UV detection. In such analyses the anions are mostly detected with indirect-UV technique. Capillary electrophoresis instruments are used to analyze samples in off-line, which seldom represent the situation in process. Therefore, on-line instrument technology with autoanalyzing settings will be needed in quality control. The development of a fully automatic capillary electrophoresis system is underway in co-operation with KCL (The Finnish Pulp and Paper Research Institute). In our research, we have first concentrated on the determination of sulphate in waters of paper industry. The method used for detection of sulphate is based on indirect-UV detection with CE, where the background electrolyte (BGE) is an absorbing mixture of secondary amines. The whole procedure for quantification of sulphate is performed within 15 minutes, after which a new sample is analyzed automatically. The only sample pretreatment is filtration, which is necessary before analysis. The concentrations of sulphate in process waters tested were between 300 and 800 ppm. Our tests show that a simultaneous determination of chloride, sulphate, nitrate, nitrite, sulphite, carbonate and oxalate is also

  2. Determination of anions with an on-line capillary electrophoresis method; Anionien on-line maeaeritys kapillaarielektroforeesilla - MPKT 10

    Energy Technology Data Exchange (ETDEWEB)

    Siren, H.; Saerme, T.; Kotiaho, T.; Hiissa, T.; Savolahti, P.; Komppa, V. [VTT Chemical Technology, Espoo (Finland)

    1998-12-31

    The aim of the study was to set-up an on-line capillary electrophoresis method for determination of anions in process waters of pulp and paper industry with exporting the results to the process control system of the mill. The quantification is important, since it will give information about the possible causes of precipitation. In recent years, the capillary electrophoresis (CE) due to its high separation efficiency has been shown as a method to take into consideration when analyzing chemical species ranging from small inorganic anions to different macromolecules. Many compounds are not easily detected in their native state, why analysis methods must be developed to improve their detection. Especially, small inorganic and organic anions which do not have chromophores are not sensitive enough for direct-UV detection. In such analyses the anions are mostly detected with indirect-UV technique. Capillary electrophoresis instruments are used to analyze samples in off-line, which seldom represent the situation in process. Therefore, on-line instrument technology with autoanalyzing settings will be needed in quality control. The development of a fully automatic capillary electrophoresis system is underway in co-operation with KCL (The Finnish Pulp and Paper Research Institute). In our research, we have first concentrated on the determination of sulphate in waters of paper industry. The method used for detection of sulphate is based on indirect-UV detection with CE, where the background electrolyte (BGE) is an absorbing mixture of secondary amines. The whole procedure for quantification of sulphate is performed within 15 minutes, after which a new sample is analyzed automatically. The only sample pretreatment is filtration, which is necessary before analysis. The concentrations of sulphate in process waters tested were between 300 and 800 ppm. Our tests show that a simultaneous determination of chloride, sulphate, nitrate, nitrite, sulphite, carbonate and oxalate is also

  3. The gas-phase on-line production of phosphoryl halides, Pox3 and their identification by infrared spectroscopy

    International Nuclear Information System (INIS)

    Allaf, A.W.

    1998-01-01

    A new route has been devised, leading to the production of Pox 3 molecules where X=F, Br and I by an on-line process using phosphoryl chloride, POCL 3 as a starting material passed over heated sodium fluoride, NaF, potassium bromide, KBr and potassium iodide, K1 at 535 Centigrade, 690 Centigrade and 480 Centigrade, respectively. The low resolution gas-phase fourier transform infrared spectra reported for the first time showed strong bands centered at 1411.6, 1322.9, 1300.8 and 1285 cm - 1, assigned to Ε 1 (a 1 ), the O = P stretching fundamental of POF 3 , POCL 3 , POBR 3 and POI 3 , respectively. Attempts were made to prepare POCL 2 and POBr 2 , by an on-line process using POCL 3 again but passed over heated sodium and potassium bromide for POCL 2 and POBr 2 . (author). 3 refs., 2 figs., 1 tab

  4. Analysis of microcontaminants in aqueous samples by fully automated on-line solid-phase extraction-gas chromatography-mass selective detection.

    NARCIS (Netherlands)

    Louter, A.J.H.; van Beekvelt, C.A.; Cid Montanes, P.; Slobodník, J.; Vreuls, J.J.; Brinkman, U.A.T.

    1996-01-01

    The trace-level analysis of unknown organic pollutants in water requires the use of fast and sensitive methods which also provide structural information. In the present study, an on-line technique was used which combines sample preparation by means of solid-phase extraction (SPE) on a small

  5. Development and Evaluation of an On-Line Educational Module for Volunteer Leaders on Bio-Security in Washington State 4-H Livestock Projects

    Science.gov (United States)

    Stevenson, Jill L.; Moore, Dale A.; Newman, Jerry; Schmidt, Janet L.; Smith, Sarah M.; Smith, Jean; Kerr, Susan; Wallace, Michael; BoyEs, Pat

    2011-01-01

    An on-line module on disease prevention was created for 4-H volunteer leaders who work with livestock projects in Washington to better prepare them to teach youth about bio-security and its importance in 4-H livestock projects. Evaluation of the module and usage statistics since the module's debut were collected and evaluated. The module increases…

  6. Experience with an on-line computer for controlling and optimizing the gas supply and the application of various peak-load supply plants of a public utility

    Energy Technology Data Exchange (ETDEWEB)

    Poll, J [Technische Werke der Stadt Stuttgart A.G. (Germany, F.R.)

    1977-02-01

    The computer system has the following tasks: 1) On-line control; 2) supply of an information system; 3) performance of a gas marketing forecast; 4) background computations. Measured data are compiled, processed, monitored, recorded, prepared, and stored. The process is controlled by about a dozen programmes, the remaining tasks are taken over by 22 programmes. The system has proved a success.

  7. On-line milk spectrometry: analysis of bovine milk composition

    Science.gov (United States)

    Spitzer, Kyle; Kuennemeyer, Rainer; Woolford, Murray; Claycomb, Rod

    2005-04-01

    We present partial least squares (PLS) regressions to predict the composition of raw, unhomogenised milk using visible to near infrared spectroscopy. A total of 370 milk samples from individual quarters were collected and analysed on-line by two low cost spectrometers in the wavelength ranges 380-1100 nm and 900-1700 nm. Samples were collected from 22 Friesian, 17 Jersey, 2 Ayrshire and 3 Friesian-Jersey crossbred cows over a period of 7 consecutive days. Transmission spectra were recorded in an inline flowcell through a 0.5 mm thick milk sample. PLS models, where wavelength selection was performed using iterative PLS, were developed for fat, protein, lactose, and somatic cell content. The root mean square error of prediction (and correlation coefficient) for the nir and visible spectrometers respectively were 0.70%(0.93) and 0.91%(0.91) for fat, 0.65%(0.5) and 0.47%(0.79) for protein, 0.36%(0.49) and 0.45%(0.43) for lactose, and 0.50(0.54) and 0.48(0.51) for log10 somatic cells.

  8. On-line electrochemical monitoring of microbially influenced corrosion

    International Nuclear Information System (INIS)

    Dowling, N.J.E.; Stansbury, E.E.; White, D.C.; Borenstein, S.W.; Danko, J.C.

    1989-01-01

    Newly emerging electrochemical measurement techniques can provide on-line, non-destructive monitoring of the average corrosion rate and indications of localized pitting corrosion together with insight into fundamental electrochemical mechanisms responsible for the corrosion process. This information is relevant to evaluating, monitoring, understanding and controlling microbially influenced corrosion (MIC). MIC of coupons exposed in sidestream devices on site or in laboratory-based experiments, where the corrosion response is accelerated by exposure to active consortia of microbes recovered from specific sites, can be utilized to evaluate mitigation strategies. The average corrosion rates can be determined by small amplitude cyclic voltametry (SACV), and AC impedance spectroscopy (EIS). EIS can also give insight into the mechanisms of the MIC and indications of localized corrosion. Pitting corrosion can be detected non-destructively with open circuit potential monitoring (OCP). OCP also responds to bacterial biofilm activities such as oxygen depletion and other electrochemical activities. Utilizing these methods, accelerated tests can be designed to direct the selection of materials, surface treatments of materials, and welding filler materials, as well as the optimization of chemical and mechanical countermeasures with the microbial consortia recovered and characterized from the specific sites of interest

  9. On-line monitoring of low-level plutonium concentrations

    International Nuclear Information System (INIS)

    Hofstetter, K.J.; Huff, G.A.; Rebagay, T.V.

    1979-10-01

    An on-line monitor has been developed to assay plutonium in nitric acid solutions. The performance of the monitor has been assessed by a laboratory experimentation program using solutions with plutonium concentrations from 0.1 to 10 g/l. These conditions are typical of the plutonium solutions in an input stream to a plutonium-purification cycle in a reprocessing plant following uranium/plutonium partitioning. The monitoring system can be fully automated and shows great promise for detecting and quantifying plutonium in situ, thus minimizing the reliance on traditional sampling and laboratory-analysis techniques. The total concentration and isotopic abundance of plutonium are determined by measuring the absolute intensities of the low-energy gamma rays characteristics of 238 Pu, 239 Pu, and 240 Pu nuclides by direct gamma-ray spectroscopy and computer analysis of the spectral data. The addition of a monitoring system of this type to the input stream of a plutonium-purification cycle along with other suitable monitors on the waste streams and on the product stream provides the basis for a near real-time materials control and inventory system. Results of the laboratory-evaluation program employing plutonium in solutions with isotopic compositions typical of those involved in processing light water reactor fuels are presented. The detailed design of a monitoring cell and detection system is given. The precision and accuracy of the results relative to those measured by mass spectrometry and controlled potential coulometry are also summarized

  10. Virtual laboratories: Collaborative environments and facilities-on-line

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, C.E. Jr. [Oak Ridge National Lab., TN (United States). I and C Div.; Cavallini, J.S.; Seweryniak, G.R.; Kitchens, T.A.; Hitchcock, D.A.; Scott, M.A.; Welch, L.C. [Dept. of Energy, Germantown, MD (United States). Mathematical Information, and Computational Sciences Div.; Aiken, R.J. [Dept. of Energy, Germantown, MD (United States). Mathematical Information, and Computational Sciences Div.]|[Lawrence Livermore National Lab., CA (United States); Stevens, R.L. [Argonne National Lab., IL (United States). Mathematics and Computer Sciences Div.

    1995-07-01

    The Department of Energy (DOE) has major research laboratories in a number of locations in the US, typically co-located with large research instruments or research facilities valued at tens of millions to even billions of dollars. Present budget exigencies facing the entire nation are felt very deeply at DOE, just as elsewhere. Advances over the last few years in networking and computing technologies make virtual collaborative environments and conduct of experiments over the internetwork structure a possibility. The authors believe that development of these collaborative environments and facilities-on-line could lead to a ``virtual laboratory`` with tremendous potential for decreasing the costs of research and increasing the productivity of their capital investment in research facilities. The majority of these cost savings would be due to increased productivity of their research efforts, better utilization of resources and facilities, and avoiding duplication of expensive facilities. A vision of how this might all fit together and a discussion of the infrastructure necessary to enable these developments is presented.

  11. The on-line low temperature nuclear orientation facility NICOLE

    International Nuclear Information System (INIS)

    Ohtsubo, T; Roccia, S; Gaulard, C; Stone, N J; Stone, J R; Köster, U; Nikolov, J; Veskovic, M; Simpson, G S

    2017-01-01

    We review major experiments and results obtained by the on-line low temperature nuclear orientation method at the NICOLE facility at ISOLDE, CERN since the year 2000 and highlight their general physical impact. This versatile facility, providing a large degree of controlled nuclear polarization, was used for a long-standing study of magnetic moments at shell closures in the region Z  = 28, N  = 28–50 but also for dedicated studies in the deformed region around A  ∼ 180. Another physics program was conducted to test symmetry in the weak sector and constrain weak coupling beyond V–A . Those two programs were supported by careful measurements of the involved solid state physics parameters to attain the full sensitivity of the technique and provide interesting interdisciplinary results. Future plans for this facility include the challenging idea of measuring the beta–gamma–neutron angular distributions from polarized beta delayed neutron emitters, further test of fundamental symmetries and obtaining nuclear structure data used in medical applications. The facility will also continue to contribute to both the nuclear structure and fundamental symmetry test programs. (paper)

  12. The Westinghouse BEACON on-line core monitoring system

    International Nuclear Information System (INIS)

    Buechel, Robert J.; Boyd, William A.; Casadei, Alberto L.

    1995-01-01

    BEACON (Best Estimate Analysis of Core Operations - Nuclear), a core monitoring and operational support package developed by Westinghouse, has been installed at many operating PWRs worldwide. The BEACON system is a real-time monitoring system which can be used in plants with both fixed and movable incore detector systems and utilizes an on-line nodal model combined with core instrumentation data to provide continuous core power distribution monitoring. In addition, accurate core-predictive capabilities utilizing a full core nodal model updated according to plant operating history can be made to provide operational support. Core history information is kept and displayed to help operators anticipate core behavior and take pro-active control actions. The BEACON system has been licensed by the U.S. Nuclear Regulatory Commission for direct, continuous monitoring of DNBR and peak linear heat rate. This allows BEACON to be integrated into the plant technical specifications to permit significant relaxation of operating limitations defined by conventional technical specifications. (author). 4 refs, 2 figs, 1 tab

  13. Development of an On-Line Uranium Enrichment Monitor

    International Nuclear Information System (INIS)

    Xuesheng, L.; Guorong, L.; Yonggang, Z.; Xueyuan, H. X.-Y.

    2015-01-01

    An on-line enrichment monitor was developed to measure the enrichment of UF6 flowing through the processing pipes in centrifuge uranium enrichment plant. A NaI(Tl) detector was used to measure the count rates of the 186 keV gamma ray emitted from 235U, and the total quantity of uranium was determined from thermodynamic characteristics of gaseous uranium hexafluoride. The results show that the maximum relative standard deviation is less than 1% when the measurement time is 120 s or more and the pressure is more than 2 kPa in the measurement chamber. There are two working models for the monitor. The monitor works normally in the continuous model, When the gas's pressure in the pipe fluctuates greatly, it can work in the intermittent model, and the measurement result is very well. The background of the monitor can be measured automatically periodically. It can control automatically electromagnetic valves open and close, so as to change the gas's quantity in the chamber. It is a kind of unattended and remote monitor, all of data can be transfer to central control room. It should be effective for nuclear materials accountability verifications and materials balance verification at uranium enrichment plant by using the monitor to monitor Uranium enrichment of gaseous uranium hexafluoride in the output end of cascade continuously. (author)

  14. On-line mass separator of superheavy atoms

    International Nuclear Information System (INIS)

    Oganesyan, Yu.Ts.

    2002-01-01

    The concept is presented of an on-line Mass Analyzer of SuperHeavy Atoms (MASHA) dedicated to the separation and determination of the mass and decay properties of new elements and isotopes produced in heavy-ion induced reactions. The new nuclides with half-lives T 1/2 ≥ 1 s are transported to an ECR-source working at a frequency of 2.45 GHz and are separated by mass with a mass resolution of M/ΔM ∼ 1500. In the focal plane of the magnetic analyzer a front strip detector surrounded by side detectors will be placed to determine the mass according to the signals from the detected α-particles or fission fragments with efficiency of about 90 %. In comparison to other existing in-flight recoil separators, the present setup will be characterized by higher efficiency and high selectivity relative to background reaction products. The setup MASHA may be used also in the investigation of nuclear reactions of different type induced by stable and radioactive beams

  15. On-Line Mass Separator of Superheavy Atoms

    CERN Document Server

    Oganessian, Yu T

    2002-01-01

    The concept is presented of an on-line Mass Analyzer of SuperHeavy Atoms (MASHA) dedicated to the separation and determination of the mass and decay properties of new elements and isotopes produced in heavy-ion induced reactions. The new nuclides with half-lives T_{1/2}\\ge 1 s are transported to an ECR-source working at a frequency of 2.45 GHz and are separated by mass with a mass resolution of M/\\Delta M\\sim 1500. In the focal plane of the magnetic analyzer a front strip detector surrounded by side detectors will be placed to determine the mass according to the signals from the detected alpha-particles or fission fragments with efficiency of about 90 %. In comparison to other existing in-flight recoil separators, the present setup will be characterized by higher efficiency and high selectivity relative to background reaction products. The setup MASHA may be used also in the investigation of nuclear reactions of different type induced by stable and radioactive beams.

  16. Optimization of an on-line function generation

    CERN Document Server

    Versteele, C

    1977-01-01

    A particular example of process control is the analog function generator of the CERN proton synchrotron. For magnet field correction, some magnets have to follow reference currents synchronous with the pulses of the synchrotron. Depending on the dynamic behaviour of the magnet system to be controlled, the output current will show a somewhat distorted image of the reference current used as input. An on-line computer strategy has been designed to compensate the distortions: i.e. to adjust the input function at successive pulses in such a way that the output current follows the reference as closely as required. However, the identification of such a system is not carried out because it is difficult and singular in any case. Modifications cannot be computed directly, but will result from an iterative strategy: the closed-loop adaptive control is based on a maximization procedure, requiring little memory and no gradient information. The algorithm is a variant of the optimization method called extended sequential se...

  17. On-line monitoring of methane in sewer air.

    Science.gov (United States)

    Liu, Yiwen; Sharma, Keshab R; Murthy, Sudhir; Johnson, Ian; Evans, Ted; Yuan, Zhiguo

    2014-10-16

    Methane is a highly potent greenhouse gas and contributes significantly to climate change. Recent studies have shown significant methane production in sewers. The studies conducted so far have relied on manual sampling followed by off-line laboratory-based chromatography analysis. These methods are labor-intensive when measuring methane emissions from a large number of sewers, and do not capture the dynamic variations in methane production. In this study, we investigated the suitability of infrared spectroscopy-based on-line methane sensors for measuring methane in humid and condensing sewer air. Two such sensors were comprehensively tested in the laboratory. Both sensors displayed high linearity (R(2) > 0.999), with a detection limit of 0.023% and 0.110% by volume, respectively. Both sensors were robust against ambient temperature variations in the range of 5 to 35°C. While one sensor was robust against humidity variations, the other was found to be significantly affected by humidity. However, the problem was solved by equipping the sensor with a heating unit to increase the sensor surface temperature to 35°C. Field studies at three sites confirmed the performance and accuracy of the sensors when applied to actual sewer conditions, and revealed substantial and highly dynamic methane concentrations in sewer air.

  18. Performing maintenance activities on-line a risk perspective

    International Nuclear Information System (INIS)

    Darling, S.S.; Mairs, T.P.

    1993-01-01

    The US nuclear power industry is attempting to deal with the issue of optimizing the performance of maintenance activities with the advent of the maintenance rule. The impact of any maintenance activity on the safe operation of a nuclear power facility can be quantified on the basis of risk. Therefore, it is incumbent upon the industry to accommodate the regulator and present a maintenance optimization program in terms that explicitly address the potential risk inherent in its concept and implementation. The motivation for utilities to perform maintenance while the plant is operating (i.e., on-line) is readily perceived to offer the following advantages: 1. greater system availability; 2. higher plant capacity factor; 3. more evenly distributed workload for the maintenance department; and 4. overall safer plant operation. However, risks inherent in undertaking maintenance activities during power operation could amount to the realization that reapportionment of these tasks is not cost-beneficial. Therefore, it is important that any utility considering implementing such a paradigm in maintenance philosophy establish a rigorous process to select, perform, and monitor maintenance tasks performed while operating

  19. An on-line tritium-in-water monitor

    International Nuclear Information System (INIS)

    Singh, A.N.; Ratnakaran, M.; Vohra, K.G.

    1985-01-01

    The paper describes the development and operation of a continuous on-line tritium-in-water monitor for the detection of heavy water leaks into the secondary coolant light water of a heavy water power reactor. The heart of the instrument is its plastic scintillator sponge detector, made from 5 μm thick plastic scintillator films. The sponge weighs only about 1 g and is in the form of disc of 48 mm diameter and 8 mm thickness. The total surface area of the films is about 3000 cm 2 . In the coincidence mode of counting, the detector gives 1000 cps for the passage of 3.7 x 10 4 Bq/cm 3 (1 μCi/cm 3 ) of tritiated water. The background in 6 cm thick lead shielding in the laboratory is 0.2 cps, and inside the reactor building it is below 1 cps. The monitor presently scans 18 sample lines in sequence for 5 min each and gives a printout for the activity in each line. (orig.)

  20. An on-line tritium-in-water monitor

    Science.gov (United States)

    Singh, A. N.; Ratnakaran, M.; Vohra, K. G.

    1985-05-01

    The paper describes the development and operation of a continuous on-line tritium-in-water monitor for the detection of heavy water leaks into the secondary coolant light water of a heavy water power reactor. The heart of the instrument is its plastic scintillator sponge detector, made from 5 μm thick plastic scintillator films. The sponge weighs only about 1 g and is in the form of disc of 48 mm diameter and 8 mm thickness. The total surface area of the films is about 3000 cm 2. In the coincidence mode of counting, the detector gives 1000 cps for the passage of 3.7 × 10 4 Bq/cm 3 (1 μCi/cm 3) of tritiated water. The background in 6 cm thick lead shielding in the laboratory is 0.2 cps, and inside the reactor building it is below 1 cps. The monitor presently scans 18 sample lines in sequence for 5 min each and gives a printout for the activity in each line.

  1. Knowledge-based on-line vibration monitoring diagnose

    International Nuclear Information System (INIS)

    Johansson, L.G.; Karlsson, A.; Noeremark, A.

    1990-01-01

    ABB STAL developed some years ago a knowledge-based on-line vibration analysis system (working-name KOVA). KOVA is intended to work together with some type of vibration monitoring system, at present it is adapted to TVM 300. KOVA has no controlling function. It will only diagnose the actual situation and give the user explanations and proposals for actions to be taken. During the developing work, great experience has been gained of the features this type of system demands. This paper will present the outlines of the application and also discuss how to make diagnoses based both on general rules as well as on historical vibration cases for that particular unit (or identical units9. Another subject that this paper will outline, is the representation and evaluation of knowledge. KOVA serves as a decision-support system for the operator. Since KOVA will often give the operator more than one possible diagnosis as the cause of a fault, it is of great importance to give the operator comprehensive explanations and as many facts as possible. It is also important to rank the suggested diagnoses in some way. In KOVA these demands are effectively supported. The models and tools used to realize this functionality will be described in this paper

  2. On-line monitoring of lithium carbonate dissolution

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yuzhu; Song, Xingfu; Wang, Jin; Luo, Yan; Yu, Jianguo [National Engineering Research Center for Integrated Utilization Salt Lake Resources, East China University of Science and Technology, Shanghai (China)

    2009-11-15

    Dissolution of lithium carbonate (Li{sub 2}CO{sub 3}) in aqueous solution was investigated using three on-line apparatuses: the concentration of Li{sub 2}CO{sub 3} was measured by electrical conductivity equipment; CLD (Chord Length Distribution) was monitored by FBRM (Focused Beam Reflectance Measurement); crystal image was observed by PVM (Particle Video Microscope). Results show dissolution rate goes up with a decrease of particle size, and with an increase in temperature; stirring speed causes little impact on dissolution; ultrasound facilitates dissolution obviously. The CLD evolution and crystal images of Li{sub 2}CO{sub 3}powders in stirred fluid were observed detailedly by FBRM and PVM during dissolution. Experimental data were fitted to Avrami model, through which the activation energy was found to be 34.35 kJ/mol. PBE (Population Balance Equation) and moment transform were introduced to calculate dissolution kinetics, obtaining correlation equations of particle size decreasing rate as a function of temperature and undersaturation. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  3. Building collaboration tools and access to on-line facilities

    International Nuclear Information System (INIS)

    Agarwal, D.; Sachs, S.

    1996-11-01

    Network-based facilities will allow researchers at different locations to collaborate on experiments as if they all were together in the same laboratory. The expected value of these geographically distributed environments includes substantially increased effectiveness in doing science, and an enabling capability for analytical and high-value production use by industry. The Distributed, Collaboratory Experiment Environments (DCEE) Program consists of four projects that were established to build prototype remote experiment and collaborative environments. The work undertaken in this project represents some of the research and development of the mechanisms and infrastructure required to make collaboratories a reality. Some of these mechanisms have already been developed. Several other mechanisms, such as data dissemination, resource management for the sharing of experiment control, safety and security, electronic notebooks, elements of telepresence, and integrated user interfaces need further research and development. The pilot application for these collaborative tools is the Advanced Light Source (ALS) Beamline 7.0 at the Ernest Orlando Lawrence Berkeley Laboratory. The ALS is a particle accelerator and is a source of very high brilliance soft X-ray beams. One experimental facility is the Spectro-Microscopy Facility Beamline 7.0. Through this project, the Spectro-Microscopy Facility will be opened up to users from a wide range of organizations. The goal is to build software that will not only put the ALS Beamline 7.0 on-line, but will also serve as building blocks for future collaboratory development

  4. EXPANDING ACADEMIC VOCABULARY WITH AN INTERACTIVE ON-LINE DATABASE

    Directory of Open Access Journals (Sweden)

    Marlise Horst

    2005-05-01

    Full Text Available University students used a set of existing and purpose-built on-line tools for vocabulary learning in an experimental ESL course. The resources included concordance, dictionary, cloze-builder, hypertext, and a database with interactive self-quizzing feature (all freely available at www.lextutor.ca. The vocabulary targeted for learning consisted of (a Coxhead's (2000 Academic Word List, a list of items that occur frequently in university textbooks, and (b unfamiliar words students had met in academic texts and selected for entry into the class database. The suite of tools were designed to foster retention by engaging learners in deep processing, an aspect that is often described as missing in computer exercises for vocabulary learning. Database entries were examined to determine whether context sentences supported word meanings adequately and whether entered words reflected the unavailability of cognates in the various first languages of the participants. Pre- and post-treatment performance on tests of knowledge of words targeted for learning in the course were compared to establish learning gains. Regression analyses investigated connections between use of specific computer tools and gains.

  5. Design considerations for on-line vibration diagnostic systems

    International Nuclear Information System (INIS)

    Branagan, L.A.; Schjeibel, J.R.

    1989-01-01

    The decisions made in the design of a data system for on-line vibration diagnostic system in power plants define how well the system will meet its intended goals. Direct use of the data for performing troubleshooting or developing operating correlations requires an understanding of the subtle impact of the design decisions incorporated in the data system. A data system includes data acquisition, data storage, and data retrieval. Data acquisition includes the selection of sensors, of vibration measurement modes, and of the time stamping format, and the arrangement of data collection cycles. Data storage requires the evaluation of data compression options and of data segregation. Data retrieval design requires an understanding of the data storage and acquisition techniques. Each of these options and design decisions involves compromises, many of which are discussed in this paper. Actual and synthetic data are presented to illustrate these points. The authors' experience with multiple data collection cycles, with frequent monitoring, and with storage by exception suggests that these techniques can be developed into an effective diagnostic system

  6. Study of the on line radioactive multicharged ion production

    International Nuclear Information System (INIS)

    Lecesne, N.

    1997-01-01

    This work is directly related to the SPIRAL project (Systeme de Production d'Ions Radioactifs Acceleres en Ligne) which will start at GANIL at the end of 1998. The aim of the thesis was to study the on line radioactive multicharged ion beam production stages, i.e. the production and diffusion of the radioactive nuclei in a thick target, their possible transfer up to an ECR ion source and their ionisation. Production cross sections of radioactive neutron rich nuclei, formed by fragmentation of a heavy ion beam in a thick target, were measured. An external target-ECR source system, dedicated to the radioactive noble gases production, and two internal target-ECR source systems, dedicated to the radioactive condensable element production, were built and tested on the SIRa tests bench (Separateur d'Ions Radioactifs). Different detection configurations were elaborated in order to identify the radioactive nuclei and estimate their production yields. Finally, a new method for measuring the overall efficiency of the separator was developed and allowed to study the diffusion properties of radioactive noble gases in various targets. (author)

  7. On-line confidence monitoring during decision making.

    Science.gov (United States)

    Dotan, Dror; Meyniel, Florent; Dehaene, Stanislas

    2018-02-01

    Humans can readily assess their degree of confidence in their decisions. Two models of confidence computation have been proposed: post hoc computation using post-decision variables and heuristics, versus online computation using continuous assessment of evidence throughout the decision-making process. Here, we arbitrate between these theories by continuously monitoring finger movements during a manual sequential decision-making task. Analysis of finger kinematics indicated that subjects kept separate online records of evidence and confidence: finger deviation continuously reflected the ongoing accumulation of evidence, whereas finger speed continuously reflected the momentary degree of confidence. Furthermore, end-of-trial finger speed predicted the post-decisional subjective confidence rating. These data indicate that confidence is computed on-line, throughout the decision process. Speed-confidence correlations were previously interpreted as a post-decision heuristics, whereby slow decisions decrease subjective confidence, but our results suggest an adaptive mechanism that involves the opposite causality: by slowing down when unconfident, participants gain time to improve their decisions. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. 3081/E processor and its on-line use

    International Nuclear Information System (INIS)

    Rankin, P.; Bricaud, B.; Gravina, M.

    1985-05-01

    The 3081/E is a second generation emulator of a mainframe IBM. One of it's applications will be to form part of the data acquisition system of the upgraded Mark II detector for data taking at the SLAC linear collider. Since the processor does not have direct connections to I/O devices a FASTBUS interface will be provided to allow communication with both SLAC Scanner Processors (which are responsible for the accumulation of data at a crate level) and the experiment's VAX 8600 mainframe. The 3081/E's will supply a significant amount of on-line computing power to the experiment (a single 3081/E is equivalent to 4 to 5 VAX 11/780's). A major advantage of the 3081/E is that program development can be done on an IBM mainframe (such as the one used for off-line analysis) which gives the programmer access to a full range of debugging tools. The processor's performance can be continually monitored by comparison of the results obtained using it to those given when the same program is run on an IBM computer. 9 refs

  9. Gated Treatment Delivery Verification With On-Line Megavoltage Fluoroscopy

    International Nuclear Information System (INIS)

    Tai An; Christensen, James D.; Gore, Elizabeth; Khamene, Ali; Boettger, Thomas; Li, X. Allen

    2010-01-01

    Purpose: To develop and clinically demonstrate the use of on-line real-time megavoltage (MV) fluoroscopy for gated treatment delivery verification. Methods and Materials: Megavoltage fluoroscopy (MVF) image sequences were acquired using a flat panel equipped for MV cone-beam CT in synchrony with the respiratory signal obtained from the Anzai gating device. The MVF images can be obtained immediately before or during gated treatment delivery. A prototype software tool (named RTReg4D) was developed to register MVF images with phase-sequenced digitally reconstructed radiograph images generated from the treatment planning system based on four-dimensional CT. The image registration can be used to reposition the patient before or during treatment delivery. To demonstrate the reliability and clinical usefulness, the system was first tested using a thoracic phantom and then prospectively in actual patient treatments under an institutional review board-approved protocol. Results: The quality of the MVF images for lung tumors is adequate for image registration with phase-sequenced digitally reconstructed radiographs. The MVF was found to be useful for monitoring inter- and intrafractional variations of tumor positions. With the planning target volume contour displayed on the MVF images, the system can verify whether the moving target stays within the planning target volume margin during gated delivery. Conclusions: The use of MVF images was found to be clinically effective in detecting discrepancies in tumor location before and during respiration-gated treatment delivery. The tools and process developed can be useful for gated treatment delivery verification.

  10. First-in-man open clinical trial of a combined rdESAT-6 and rCFP-10 tuberculosis specific skin test reagent.

    Directory of Open Access Journals (Sweden)

    Winnie Bergstedt

    2010-06-01

    Full Text Available Tuberculin is still the only available skin test reagent for the diagnosis of mycobacterial infection. The product has a remarkable sensitivity, but poor specificity. Previous studies, including two human phase I clinical trials, have indicated that rdESAT-6 has a potential as an improved skin test reagent. Animal studies have shown that the sensitivity may be increased by inclusion of the genetically related CFP-10 antigen in the preparation without loosing specificity.In this study a Lactococcus fermented, recombinant skin test reagent consisting of a 1ratio1 wt/wt of rdESAT-6 and CFP-10 was manufactured according to GMP standards and tested for the first time in 42 healthy adult volunteers. The two doses of 0.01 microg or 0.1 microg were injected intradermally by the Mantoux technique with 6 or 12 weeks interval. No serious adverse events and only mild adverse reactions were reported. The reagent elicited a positive skin test reaction after the first injection in one participant, who most likely was latently infected with M. tuberculosis as indicated by an appreciable IFN gamma response just below the Quantiferon(R cut-off level at the screening visit. None of the remaining participants in the four groups had any skin test reactions and sensitisation by the reagent could therefore be excluded.The investigational skin test reagent rdESAT-6 and CFP-10 appeared safe and non-sensitising in this first-in-man clinical trial in human volunteers and can now be tested in larger clinical trials involving individuals with latent M. tuberculosis infection or active TB disease.ClinicalTrials.gov NCT00793702.

  11. Application of cyanuric chloride-based six new chiral derivatizing reagents having amino acids and amino acid amides as chiral auxiliaries for enantioresolution of proteinogenic amino acids by reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Bhushan, Ravi; Dixit, Shuchi

    2012-04-01

    Six dichloro-s-triazine (DCT) reagents having L-Leu, D-Phg, L-Val, L-Met, L-Ala and L-Met-NH(2) as chiral auxiliaries in cyanuric chloride were introduced for enantioseparation of 13 proteinogenic amino acids. Four other DCTs and six monochloro-s-triazine (MCT) reagents having amino acid amides as chiral auxiliaries were also synthesized. These 16 chiral derivatizing reagents (CDRs) were used for synthesis of diastereomers of all the 13 analytes using microwave irradiation, which were resolved by reversed-phase high-performance liquid chromatography (RP-HPLC) using C18 column and gradient eluting mixture of aqueous TFA and acetonitrile with UV detection at 230 nm. It required only 60-90 s for derivatization using microwave irradiation. Better resolution and lower retention times were observed for the diastereomers prepared with CDRs having amino acids as chiral auxiliaries as compared to counterparts prepared with reagents having amino acid amides as chiral auxiliaries. As the best resolution of all the 13 analytes was observed for their diastereomers prepared using the DCT reagent having L-Leu as chiral auxiliary, this CDR was further employed for derivatization of Lys, Tyr, His and Arg followed by RP-HPLC analysis of resulting diastereomers. The results are discussed in light of acid and amide groups of chiral auxiliaries constituting CDRs, electronegativities of the atoms of achiral moieties constituting CDRs and hydrophobicities of side chains of amino acids constituting CDRs and analytes.

  12. Analysis of flavonoids from propolis by on-line HPLC-electrospray mass spectrometry.

    Science.gov (United States)

    Volpi, Nicola; Bergonzini, Gianluca

    2006-09-26

    In this paper, the qualitative and quantitative separation and determination of the polyphenolic component of propolis preparations in the form of ethanolic extract, usually used for commercial pharmaceutical preparations, has been investigated by means of on-line HPLC-ESI/MS technique. Propolis of different origin have been evaluated for their components and a specific fingerprint has been determined potentially useful for the quality control of extracts in pharmaceutical preparations. The ethanolic extracts of propolis from Argentina, Italy and Spain shows approximately the same total ion chromatogram (TIC) profile due to the presence of the same molecular species, identified by the negative ESI-MS. On the contrary, the samples from Azerbaijan, China, Ethiopia and Kenya show a very peculiar TIC profiles. By using many purified flavonoids and calibration curves over a wide concentration range, from 0.05 (5 microg/ml) to 5 microg (500 microg/ml), an accurate assessment of the contents of several bioactive compounds in extract samples was performed. The propolis from Argentina, Italy and Spain show a great amount of pinocembrin (approximately 49%, 48% and 39% of the total identified flavonoids, respectively) and variable but similar percentages of the other species. On the contrary, the propolis from China, Azerbaijan and Ethiopia have a great amount of pinocembrin (approximately 63%, 46% and 62%, respectively) but no presence of genistein, kaempferol, apigenin and chrysin for the sample from China, genistein, kaempferol, acacetin and chrysin for the propolis from Azerbaijan, and no kaempferol and acacetin for the sample from Ethiopia. The ethanolic extract from propolis of Kenya has no identified flavonoid species but just a peak possessing a m/z of 253.0. Finally, an evaluation of the presence of total flavonoids for the various propolis samples was performed, with extracts from Argentina, Italy and Spain more rich in polyphenols than those from Azerbaijan, China

  13. A study on the computerization of secondary side on-line chemistry monitoring system of PWR

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Kyung Lin; Lee, Eun Heui [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-12-01

    A computer system for on-line chemistry monitoring system located in secondary side of PWR plant is under developing. Keithley 500 A mainframe and AMM1A and AIM3A modules are used for data acquisition and scientific and engineering software package of ASYST is used for developing software program. The contents are as follows: (1) Data acquisition and real-time display. The output signals of monitoring chemical sensors are stored in PC showing real-time data display as true values and graphics. (2) Data management and trending graphs. The data stored in PC are outcoming in various graphic mode for data management such as simple trending graphs screen display, time duration plot and histogram plot. (3) Daily basis data manual input. The chemical analysis data of grab sample are stored in PC by manual input for supplement data. (4) Tabular data report preparation. Summarized daily, weekly, monthly, quarterly and yearly reports are prepared with various mode of graphic display. 6 figs, 9 tabs, 8 refs. (Author).

  14. A study on the computerization of secondary side on-line chemistry monitoring system of PWR

    International Nuclear Information System (INIS)

    Yang, Kyung Lin; Lee, Eun Heui

    1994-12-01

    A computer system for on-line chemistry monitoring system located in secondary side of PWR plant is under developing. Keithley 500 A mainframe and AMM1A and AIM3A modules are used for data acquisition and scientific and engineering software package of ASYST is used for developing software program. The contents are as follows: 1) Data acquisition and real-time display. The output signals of monitoring chemical sensors are stored in PC showing real-time data display as true values and graphics. 2) Data management and trending graphs. The data stored in PC are outcoming in various graphic mode for data management such as simple trending graphs screen display, time duration plot and histogram plot. 3) Daily basis data manual input. The chemical analysis data of grab sample are stored in PC by manual input for supplement data. 4) Tabular data report preparation. Summarized daily, weekly, monthly, quarterly and yearly reports are prepared with various mode of graphic display. 6 figs, 9 tabs, 8 refs. (Author)

  15. Using Reading Guides and On-Line Quizzes to Improve Reading Compliance and Quiz Scores

    Science.gov (United States)

    Maurer, Trent W.; Longfield, Judith

    2015-01-01

    This study compared students' daily in-class reading quiz scores in an introductory Child Development course across five conditions: control, reading guide only, reading guide and on-line practice quiz, reading guide and on-line graded quiz, and reading guide and both types of on-line quizzes. At the beginning of class, students completed a 5-item…

  16. On-line Versus Face-to-Face Education: Utilizing Technology to Increase Effectiveness

    Science.gov (United States)

    2012-05-17

    Andragogy and learner-centered education provided in on-line education present excellent results. Secondly, the cost of on-line education compared to...13 Pedagogy versus Andragogy ...achieving learning outcomes. However, Andragogy and learner centered education provided in on-line education presents excellent results. Secondly, the cost

  17. Automated system for on-line determination of dimethylarsinic and inorganic arsenic by hydride generation-atomic fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Chaparro, L.L.; Leal, L.O. [Renewable Energy and Environmental Protection Department, Advanced Materials Research Center (CIMAV), Chihuahua, Chihuahua (Mexico); Ferrer, L.; Cerda, V. [University of the Balearic Islands, Department of Chemistry, Palma de Mallorca (Spain)

    2012-09-15

    A multisyringe flow-injection approach has been coupled to hydride generation-atomic fluorescence spectrometry (HG-AFS) with UV photo-oxidation for dimethylarsinic (DMA), inorganic As and total As determination, depending on the pre-treatment given to the sample (extraction or digestion). The implementation of a UV lamp allows on-line photo-oxidation of DMA and the following arsenic detection, whereas a bypass leads the flow directly to the HG-AFS system, performing inorganic arsenic determination. DMA concentration is calculated by the difference of total inorganic arsenic and measurement of the photo-oxidation step. The detection limits for DMA and inorganic arsenic were 0.09 and 0.47 {mu}g L{sup -1}, respectively. The repeatability values accomplished were of 2.4 and 1.8 %, whereas the injection frequencies were 24 and 28 injections per hour for DMA and inorganic arsenic, respectively. This method was validated by means of a solid reference material BCR-627 (muscle of tuna) with good agreement with the certified values. Satisfactory results for DMA and inorganic arsenic determination were obtained in several water matrices. The proposed method offers several advantages, such as increasing the sampling frequency, low detection limits and decreasing reagents and sample consumption, which leads to lower waste generation. (orig.)

  18. The effect of family therapy on the changes in the severity of on-line game play and brain activity in adolescents with on-line game addiction

    Science.gov (United States)

    Han, Doug Hyun; Kim, Sun Mi; Lee, Young Sik; Renshaw, Perry F.

    2015-01-01

    We evaluated whether a brief 3-week family therapy intervention would change patterns of brain activation in response to affection and gaming cues in adolescents from dysfunctional families who met criteria for on-line game addiction. Fifteen adolescents with on-line game addiction and fifteen adolescents without problematic on-line game play and an intact family structure were recruited. Over 3 weeks, families were asked to carry out homework assignments focused on increasing family cohesion for more than 1 hour/day and 4 days/week. Before therapy, adolescents with on-line game addiction demonstrated decreased activity as measured by functional magnetic resonance imaging (fMRI) within the caudate, middle temporal gyrus, and occipital lobe in response to images depicting parental affection and increased activity of the middle frontal and inferior parietal in response scenes from on-line games, relative to healthy comparison subjects. Improvement in perceived family cohesion following 3 weeks of treatment was associated with an increase in the activity of the caudate nucleus in response to affection stimuli and was inversely correlated with changes in on-line game playing time. With evidence of brain activation changes in response to on-line game playing cues and images depicting parental love, the present findings suggest that family cohesion may be an important factor in the treatment of problematic on-line game playing. PMID:22698763

  19. Desalting Protein Ions in Native Mass Spectrometry Using Supercharging Reagents

    Science.gov (United States)

    Cassou, Catherine A.; Williams, Evan R.

    2014-01-01

    Effects of the supercharging reagents m-NBA and sulfolane on sodium ion adduction to protein ions formed using native mass spectrometry were investigated. There is extensive sodium adduction on protein ions formed by electrospray ionization from aqueous solutions containing millimolar concentrations of NaCl, which can lower sensitivity by distributing the signal of a given charge state over multiple adducted ions and can reduce mass measuring accuracy for large proteins and non-covalent complexes for which individual adducts cannot be resolved. The average number of sodium ions adducted to the most abundant ion formed from ten small (8.6–29 kDa) proteins for which adducts can be resolved is reduced by 58% or 80% on average, respectively, when 1.5% m-NBA or 2.5% sulfolane are added to aqueous solutions containing sodium compared to without the supercharging reagent. Sulfolane is more effective than m-NBA at reducing sodium ion adduction and at preserving non-covalent protein-ligand and protein-protein interactions. Desalting with 2.5% sulfolane enables detection of several glycosylated forms of 79.7 kDa holo-transferrin and NADH bound to the 146 kDa homotetramer LDH, which are otherwise unresolved due to peak broadening from extensive sodium adduction. Although sulfolane is more effective than m-NBA at protein ion desalting, m-NBA reduces salt clusters at high m/z and can increase the signal-to-noise ratios of protein ions by reducing chemical noise. Desalting is likely a result of these supercharging reagents binding sodium ions in solution, thereby reducing the sodium available to adduct to protein ions. PMID:25133273

  20. A review of reagents for fluorescence microscopy of cellular compartments and structures, Part III: reagents for actin, tubulin, cellular membranes, and whole cell and cytoplasm.

    Science.gov (United States)

    Kilgore, Jason A; Dolman, Nick J; Davidson, Michael W

    2014-01-02

    Non-antibody commercial fluorescent reagents for imaging of cytoskeletal structures have been limited primarily to tubulin and actin, with the main factor in choice based mainly on whether cells are live or fixed and permeabilized. A wider range of options exist for cell membrane dyes, and the choice of reagent primarily depends on the preferred localization in the cell (i.e., all membranes or only the plasma membrane) and usage (i.e., whether the protocol involves fixation and permeabilization). For whole-cell or cytoplasmic imaging, the choice of reagent is determined mostly by the length of time that the cells need to be visualized (hours or days) and by fixation status. Presented here is a discussion on choosing commercially available reagents for these cellular structures, with an emphasis on use for microscopic imaging, with a featured reagent for each structure, a recommended protocol, troubleshooting guide, and example image. Copyright © 2014 John Wiley & Sons, Inc.

  1. In situ microscopy for on-line determination of biomass.

    Science.gov (United States)

    Bittner, C; Wehnert, G; Scheper, T

    1998-10-05

    A sensor is presented, which allows on-line microscopic observation of microorganisms during fermentations in bioreactors. This sensor, an In Situ Microscope (ISM) consists of a direct-light microscope with a measuring chamber, integrated in a 25 mm stainless steel tube, two CCD-cameras, and two frame-grabbers. The data obtained are processed by an automatic image analysis system. The ISM is connected with the bioreactor via a standard port, and it is immersed directly in the culture liquid-in our case Saccharomyces cerevisiae in a synthetic medium. The microscopic examination of the liquid is performed in the measuring chamber, which is situated near the front end of the sensor head. The measuring chamber is opened and closed periodically. In the open state, the liquid in the bioreactor flows unrestricted through the chamber. In closing, a defined volume of 2,2. 10(-8) mL of the liquid becomes enclosed. After a few seconds, when the movement of the cells in the enclosed culture has stopped, they are examined with the microscope. The microscopic images of the cells are registered with the CCD-cameras and are visualized on a monitor, allowing a direct view of the cell population. After detection, the measuring chamber reopens, and the enclosed liquid is released. The images obtained are evaluated as to cell concentration, cell size, cell volume, biomass, and other relevant parameters simultaneously by automatic image analysis. With a PC (486/33 MHz), image processing takes about 15 s per image. The detection range tested when measuring cells of S. cerevisiae is about 10(6) to 10(9) cells/mL (equivalent to a biomass of 0.01 g/L to 12 g/L). The calculated biomass values correlate very well with those obtained using dry weight analysis. Furthermore, histograms can be calculated, which are comparable to those obtained by flow cytometry. Copyright 1998 John Wiley & Sons, Inc.

  2. Functionalization of epoxy esters with alcohols as stoichiometric reagents.

    Science.gov (United States)

    Pavlović, Dona; Modec, Barbara; Dolenc, Darko

    2015-01-01

    Glycidyl esters, frequently employed as reactive groups on polymeric supports, were functionalized with alcohols as stoichiometric reagents, yielding β-alkoxyalcohols. Among the solvents studied, best results were obtained in ethers in the presence of a strong proton acid as a catalyst. Alcohols include simple alkanols, diols, protected polyols, 3-butyn-1-ol 3-hydroxypropanenitrile and cholesterol. This protocol represents a convenient way for introduction of various functionalities onto epoxy-functionalized polymers. Under the reaction conditions, some side reactions take place, mostly due to the reactive ester group and water present in the reaction mixture.

  3. On-line sensor technology for food manufacturing industry. Shokuhin bun prime ya ni okeru on-line sensor gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Komiya, K. (Ajinomoto Co. Inc., Tokyo (Japan))

    1990-08-05

    This paper introduced the sensor technology for food manufacturing industry. If sugar concentration in main raw material is too high in the amino acid fermentation, control of the concentration is required because fungi growth is inhibited. A controlling method for sugar concentration was developed by using the correlation between consumption of NH {sub 3} for pH adjustment and sugar consumption in place of conventional analyzing method and was introduced in the gulutamic acid fermantation. BOD sensor was developed to enable the selective measurement of organic substances which can be processed by organisms, and measuring time was shortened from previous five days to 30 minutes. Since many organics absorb infrared ray, near infrared analysis is suitable for food analysis and on-line analysis has high possibility. When this method is applied to measure moisture in fishes and meats, continuous measurement can be made nondestructively and without contacting, and further the precision is {plus minus} 0.1%. Simultaneous multi-composition analyses are carried out by continuous spectrum and near infrared method using higher rate scanning. Sensor development for taste and smell has started. 10 refs., 4 figs., 4 refs.

  4. On-line coupled LC-LC-GC for irradiation detection in complex lipid matrices

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Helle, N.; Boegl, K.W.; Schreiber, G.A.

    1993-01-01

    Since sample preparation with HPLC coupled on-line to the GC has been performed for only a few weeks in our laboratory, the results presented give a first look at what can be done by means of this technique. Even difficult samples as the described fish species, where an unequivocal identification regarding an irradiation treatment seemed to become a hopeless enterprise, could be managed. Because of the greater variety of fatty acids in fish ''new'' radiation-induced hydrocarbons were available. According to the theory of Nawar in addition to 16:2 and 17:2 hydrocarbons we have looked for in irradiated meat, further alkadienes appeared in irradiated fish, which were 14:2, 18:2 and 20:2. Analysis of the alkadiene-fraction, transferred to the GC after a two step LC clean up, resulted in an unequivocal identification of all fish samples as well as the fruits and sponge cake. For fruits and sponge cake the detection limit seems to be clearly below 0.5 kGy. It can further be lowered by increasing the amount of lipid whereas the upper limit for a certain LC column has to be determined. In contrast to these samples only qualitative results were obtained for fish. In the case of sponge cake for the first time irradiation of a component of a heat treated food was detected. Further investigations regarding reproducibility, dose dependence and detection limit have to be done. On-line coupled (LC-)LC-GC was proved to be a highly efficient method for analysis of complex samples. In contrast to off-line Florisil column chromatography only a small part of the initial lipid material is needed because the complete hydrocarbon fraction is transferred on-line to the GC. This offers the possibility to analyze even foods with a low fat content like various seafoods. Classification of the hydrocarbon fraction by a two step LC may facilitate the identification of the radiolytic products also if no mass spectrometric detection system is available. (orig./vhe)

  5. Pedagogical directions to design and support collaborative knowledge building on-line tasks

    Directory of Open Access Journals (Sweden)

    Ingrid Noguera Fructuoso

    2013-02-01

    Full Text Available 0 0 1 187 1034 USAL 8 2 1219 14.0 Normal 0 21 false false false ES JA X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Tabla normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin-top:0cm; mso-para-margin-right:0cm; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0cm; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:Calibri; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-ansi-language:ES; mso-fareast-language:EN-US;} Research on Computer-Supported Collaborative Learning (CSCL demonstrates that proposing that students work in groups does not improve their learning or increase their motivation. It is essential to design appropriate learning tasks and suitable pedagogical and technological support. The aim of this research is to identify pedagogical directions to design and support collaborative knowledge building tasks in on-line education. We conducted a case study at the Open University of Catalonia where we carried out two experiments: the first focusing on how teachers design and support collaborative on-line learning tasks and, the second, based on the control exerted over the tasks. As a result of the investigation we characterize the type of tasks that promote collaborative knowledge building, the teachers’ role and functions supporting these types of tasks, and we identify different stages in task regulation. Based on these results, we propose pedagogical directions to design and support collaborative on-line tasks divided into 4 stages: 1 Task design and individual preparation, 2 Task organization and group negotiation, 3 Task performance and collaborative knowledge building, and 4 Critical evaluation.

  6. Validity of HydraTrend reagent strips for the assessment of hydration status.

    Science.gov (United States)

    Abbey, Bryce M; Heelan, Kate A; Brown, Gregory A; Bartee, Rodrick T

    2014-09-01

    Hydration is used by athletic governing organizations for weight class eligibility. The measurement of urine specific gravity (USG) as a measure of hydration by reagent strips is a controversial issue. The purpose of this study was to determine the validity of HydraTrend reagent strips that facilitate the correction of USG for alkaline urine samples against refractometry for the assessment of USG. Fifty-one participants (33 males, age = 22.3 ± 1.3 years; 18 females, age = 22.4 ± 1.2 years) provided 84 urine samples. The samples were tested for USG using refractometry and reagent strips and for pH using reagent strips and a digital pH meter. Strong correlation coefficients were found between refractometry and reagent strips for USG (rs(82) = 0.812, p refractometry with USG >1.020, pass reagent strips with USG ≤1.020) occurred 39% (33/84) of the time and false negative results for National Federation of State High School Association (NFHS) requirements (fail refractometry with USG >1.025, pass reagent strips with USG ≤1.025) occurred 14% (12/84) of the time. There were no false positives (pass refractometry and fail reagent strips) for NCAA or NFHS requirements. These data show that refractometry and reagent strips have strong positive correlations. However, the risk of a false negative result leading to incorrect certification of euhydration status outweighs the benefits of the HydraTrend reagent strips for the measurement of USG.

  7. Influence of the apparent molecular size of humic substances on the efficiency of coagulation using Fenton's reagent

    Directory of Open Access Journals (Sweden)

    MARCELO DE JULIO

    2013-06-01

    Full Text Available This work used Fenton's reagent as a coagulating agent in the treatment of water samples with high true colour caused by humic substances (HS extracted from peat. In addition, the effects of the apparent molecular size of HS on coagulation, flocculation and flotation were studied. To that end, four distinct water samples having the same true colour were prepared using HS with different molecular sizes, which were obtained by ultrafiltration fractioning. Through optimisation of coagulant dosage and coagulation pH, as well as posterior construction of coagulation diagrams for each water sample, it was verified that the sample prepared with the smallest apparent molecular size of HS was the most difficult to treat, requiring higher coagulant (Fenton's reagent dosages than samples prepared with larger HS molecular sizes. Furthermore, filtration experiments after dissolved air flotation (DAF were carried out in an attempt to simulate conventional treatment. The most representative results in filtered water were: apparent colour ≤ 3 HU; turbidity Este trabalho empregou o reagente de Fenton como agente coagulante no tratamento de águas contendo cor elevada causada pela introdução de substâncias húmicas extraídas de turfa. Além disto, foi estudado o efeito do tamanho molecular aparente das substâncias húmicas na eficiência da coagulação, floculação e flotação de águas; para isto foram preparadas quatro águas distintas apresentado a mesma cor verdadeira, mas com substâncias húmicas de diferentes tamanhos moleculares, obtidas por fracionamento por ultrafiltração. Por meio da otimização da dosagem de coagulante e respectivo pH de coagulação e posterior construção dos diagramas de coagulação para cada água de estudo, verificou-se que a água preparada com as substâncias húmicas de menor tamanho molecular aparente apresentou maior grau de dificuldade para tratamento, requerendo dosagens de coagulante (reagente de Fenton bem

  8. Potassium N-Iodo p-Toluenesulfonamide (TsNIK, Iodamine-T): A New Reagent for the Oxidation of Hydrazones to Diazo Compounds

    Science.gov (United States)

    Nicolle, Simon M; Moody, Christopher J

    2014-01-01

    A new reagent for the oxidation of hydrazones to diazo compounds is described. N-Iodo p-toluenesulfonamide (TsNIK, iodamine-T) allows the preparation of α-diazoesters, α-diazoamides, α-diazoketones and α-diazophosphonates in good yield and in high purity after a simple extractive work-up. α-Diazoesters were also obtained in high yield from the corresponding ketones through a one-pot process of hydrazone formation/oxidation. PMID:24615944

  9. Diagnóstico das meningites através de fitas reagentes Diagnosis of meningitis with reagent strips

    Directory of Open Access Journals (Sweden)

    Roberta M.C. Romanelli

    2001-06-01

    Full Text Available OBJETIVO: determinar a utilidade de fitas reagentes para a avaliação liquórica de pleocitose, glicorraquia e proteinorraquia no diagnóstico precoce e rápido de meningites em crianças. MÉTODOS: Foram incluídas no estudo amostras de líquor provenientes de 164 crianças admitidas no ambulatório de doenças infecto-contagiosas do Centro Geral de Pediatria (CGP-FHEMIG, com suspeita clínica de meningite, no período diurno de Maio/97 à Maio/99. A faixa etária dos pacientes variou de um mês a 12 anos (mediana de 12 meses, sendo obtidos resultados da citobioquímica liquórica (celularidade, glicorraquia e proteinorraquia de 154 desses pacientes. Esses achados foram comparados com reações do líquor em fitas reagentes. RESULTADOS: Através da citobioquímica líquórica foram identificados 43 casos de provável meningite bacteriana, 19 provavelmente viróticas e 83 amostras sem alterações. Pelas fitas reagentes, detectaram-se 41 casos de provável meningite bacteriana, dois casos de infecção meníngea provavelmente virótica, e em 71 exames não se verificaram alterações. Comparando os resultados obtidos por meio das fitas reagentes com a citobioquímica convencional, observou-se sensibilidade, especificidade, valores preditivos positivo e negativo e acurácia (90,7; 98,1; 95,1; 96,4; 96,1%, respectivamente. Ademais, a análise estatística pelo teste de Mc Nemar não evidenciou discordância significativa no diagnóstico de meningite bacteriana obtido através de ambos os métodos (p=0,68 e, pela estatística Kappa, verificou-se elevado grau de concordância entre os testes (pOBJECTIVE: to determine the usefulness of reagent strips in the evaluation of pleocytosis, cerebrospinal fluid glucose and protein levels for early and rapid diagnosis of meningitis in children. METHODS: We included cerebrospinal fluid samples of 164 children admitted to the outpatient clinic of Communicable Diseases of the General Pediatric Center (Funda

  10. Optically transparent, superhydrophobic methyltrimethoxysilane based silica coatings without silylating reagent

    International Nuclear Information System (INIS)

    Kavale, Mahendra S.; Mahadik, D.B.; Parale, V.G.; Wagh, P.B.; Gupta, Satish C.; Rao, A.Venkateswara; Barshilia, Harish C.

    2011-01-01

    The superhydrophobic surfaces have drawn lot of interest, in both academic and industries because of optically transparent, adherent and self-cleaning behavior. Surface chemical composition and morphology plays an important role in determining the superhydrophobic nature of coating surface. Such concert of non-wettability can be achieved, using surface modifying reagents or co-precursor method in sol-gel process. Attempts have been made to increase the hydrophobicity and optical transparency of methyltrimethoxysilane (MTMS) based silica coatings using polymethylmethacrylate (PMMA) instead of formal routes like surface modification using silylating reagents. The optically transparent, superhydrophobic uniform coatings were obtained by simple dip coating method. The molar ratio of MTMS:MeOH:H 2 O was kept constant at 1:5.63:1.58, respectively with 0.5 M NH 4 F as a catalyst and the weight percent of PMMA varied from 1 to 8. The hydrophobicity of silica coatings was analyzed by FTIR and contact angle measurements. These substrates exhibited 91% optical transmittance as compared to glass and water drop contact angle as high as 171 ± 1 deg. The effect of humidity on hydrophobic nature of coating has been studied by exposing these films at relative humidity of 90% at constant temperature of 30 deg. C for a period of 45 days. The micro-structural studies carried out by transmission electron microscopy (TEM).

  11. The blocking reagent optimization for the magnetoelastic biosensor

    Science.gov (United States)

    Hu, Jiajia; Chai, Yating; Horikawa, Shin; Wikle, Howard C.; Wang, Feng'en; Du, Songtao; Chin, Bryan A.; Hu, Jing

    2015-06-01

    The wireless phage-based magnetoelastic (ME) biosensor has proven to be promising for real-time detection of pathogenic bacteria on fresh produces. The ME biosensor consists of a freestanding ME resonator as the signal transducer and filamentous phage as the biomolecular-recognition element, which can specifically bind to a pathogen of interest. Due to the Joule magnetostriction effect, the biosensors can be placed into mechanical resonance when subjected to a time-varying magnetic field alternating at the sensor's resonant frequency. Upon the attachment of the target pathogen, the mass of the biosensor increases, thereby decreasing its resonant frequency. This paper presents an investigation of blocking reagents immobilization for detecting Salmonella Typhimurium on fresh food surfaces. Three different blocking reagents (BSA, SuperBlock blocking buffer, and blocker BLOTTO) were used and compared. The optical microscope was used for bacterial cells binding observation. Student t-test was used to statistically analysis the experiment results. The results shows that SuperBlock blocking buffer and blocker BLOTTO have much better blocking performance than usually used BSA.

  12. Radiation chemical technology of industrial polymer reagents development

    International Nuclear Information System (INIS)

    Kudaibergenov, S.; Nurkeeva, Z.; Mun, G.; Sigitov, V.; Maltzeva, R.; Petukhov, V.; Tchekushin, A.

    1996-01-01

    The goal of this project is to develop the technology of producing of polymeric reagents from the raw materials of Kazakstan for application in medicine, agriculture, enhanced oil recovery and ecology. To achieve the objectives the next technological lines or operations (Blocks) should be realized: 1. Rectification column and distilling apparatus for purification of monomers and solvents including analytical equipment to control the quality of the final product; 2. Irradiation of reaction mixture by either gamma-irradiation source Co-60; 3. Purification of polymer reagents; 4. Producing of commercial products. It is supposed that the power irradiation devices for producing of hydrogels will be mounted on the research atomic reactor of the Almaty Branch of the Institute of Atomic Energy of the National Nuclear Center. There are high qualification personal which has much experience in radioactive materials operating. Irradiation technologies will provide the low cost of hydrogels, approximately 250-300 US$ per 1 ton. Expected results. One can expect that the realization of this project allows to produce hydrogels in industrial scale to cover partly the requirements of medicine, agriculture, oil industry and ecology

  13. Total Synthesis of Natural Products Using Hypervalent Iodine Reagents

    Directory of Open Access Journals (Sweden)

    Gaetan eMaertens

    2015-01-01

    Full Text Available We present a review of natural product syntheses accomplished in our laboratory during the last five years. Each synthetic route features a phenol dearomatization promoted by an environmentally benign hypervalent iodine reagent. The dearomatizations demonstrate the aromatic ring umpolung concept, and involve stereoselective remodeling of the inert unsaturations of a phenol into a highly functionalized key intermediate that may contain a quaternary carbon center and a prochiral dienone system. Several new oxidative strategies were employed, including transpositions (1,3-alkyl shift and Prins-pinacol, a polycyclization, an ipso rearrangement, and direct nucleophilic additions at the phenol para position. Several alkaloids, heterocyclic compounds, and a polycyclic core have been achieved, including sceletenone (a serotonin reuptake inhibitor, acetylaspidoalbidine (an antitumor agent, fortucine (antiviral and antitumor, erysotramidine (curare-like effect, platensimycin (an antibiotic, and the main core of a kaurane diterpene (immunosuppressive agent and stimulator of apoptosis. These concise and in some cases enantioselective syntheses effectively demonstrate the importance of hypervalent iodine reagents in the total synthesis of bioactive natural products.

  14. Classical kinematic model for direct reactions of oriented reagents

    International Nuclear Information System (INIS)

    Schechter, I.; Prisant, M.G.; Levine, R.D.

    1987-01-01

    A simple kinematic model based on the concept of an orientation-dependent critical configuration for reaction is introduced and applied. The model serves two complementary purposes. In the predictive mode the model provides an easily implemented procedure for computing the reactivity of oriented reagents (including those actually amenable to measure) from a given potential energy surface. The predictions of the model are compared against classical trajectory results for the H + D 2 reaction. By use of realistic potential energy surfaces the model is applied to the Li + HF and O + HCl reactions where the HX molecules are pumped by a polarized laser. A given classical trajectory is deemed reactive or not according to whether it can surmount the barrier at that particular orientation. The essential difference with the model of Levine and Bernstein is that the averaging over initial conditions is performed by using a Monte Carlo integration. One can therefore use the correct orientation-dependent shape (and not only height) of the barrier to reaction and, furthermore, use oriented or aligned reagents. Since the only numerical step is a Monte Carlo sampling of initial conditions, very many trajectories can be run. This suffices to determine the reaction cross section for different initial conditions. To probe the products, they have employed the kinematic approach of Elsum and Gordon. The result is a model where, under varying initial conditions, examining final-state distributions or screening different potential energy surfaces can be efficiently carried out

  15. Tunable, Quantitative Fenton-RAFT Polymerization via Metered Reagent Addition.

    Science.gov (United States)

    Nothling, Mitchell D; McKenzie, Thomas G; Reyhani, Amin; Qiao, Greg G

    2018-05-10

    A continuous supply of radical species is a key requirement for activating chain growth and accessing quantitative monomer conversions in reversible addition-fragmentation chain transfer (RAFT) polymerization. In Fenton-RAFT, activation is provided by hydroxyl radicals, whose indiscriminate reactivity and short-lived nature poses a challenge to accessing extended polymerization times and quantitative monomer conversions. Here, an alternative Fenton-RAFT procedure is presented, whereby radical generation can be finely controlled via metered dosing of a component of the Fenton redox reaction (H 2 O 2 ) using an external pumping system. By limiting the instantaneous flux of radicals and ensuring sustained radical generation over tunable time periods, metered reagent addition reduces unwanted radical "wasting" reactions and provides access to consistent quantitative monomer conversions with high chain-end fidelity. Fine tuning of radical concentration during polymerization is achieved simply via adjustment of reagent dose rate, offering significant potential for automation. This modular strategy holds promise for extending traditional RAFT initiation toward more tightly regulated radical concentration profiles and affords excellent prospects for the automation of Fenton-RAFT polymerization. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Flow-injection fluorimetric determination of menadione using on-line photo-reduction in micellar media

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Ruiz, Tomas; Martinez-Lozano, Carmen; Tomas, Virginia; Martin, Jesus

    2004-07-01

    A very sensitive fluorimetric method for the determination of menadione using a flow injection system is proposed. The method is based on the on-line reduction of menadione in dodecylsulphate micelles upon irradiation with UV light. The strong fluorescence of the reduced menadione in micellar medium is measured at 410 nm with excitation at 340 nm. The method shows a linear range between 2.42 and 245 ng ml{sup -1} and a limit of detection of 0.18 ng ml{sup -1}. The sample throughput was 90 injections per hour. The applicability of the assay was demonstrated by analysing this vitamin in commercial pharmaceutical preparations.

  17. Flow-injection fluorimetric determination of menadione using on-line photo-reduction in micellar media

    International Nuclear Information System (INIS)

    Perez-Ruiz, Tomas; Martinez-Lozano, Carmen; Tomas, Virginia; Martin, Jesus

    2004-01-01

    A very sensitive fluorimetric method for the determination of menadione using a flow injection system is proposed. The method is based on the on-line reduction of menadione in dodecylsulphate micelles upon irradiation with UV light. The strong fluorescence of the reduced menadione in micellar medium is measured at 410 nm with excitation at 340 nm. The method shows a linear range between 2.42 and 245 ng ml -1 and a limit of detection of 0.18 ng ml -1 . The sample throughput was 90 injections per hour. The applicability of the assay was demonstrated by analysing this vitamin in commercial pharmaceutical preparations

  18. Isotopic nuclear reactor with on-line separation

    International Nuclear Information System (INIS)

    Liviu, Popa-Simil

    2007-01-01

    In the new reactor-waste cycle design the nuclear reactor gets features of the living beings - resembling the plants/vegetation -. The separation of waste starts inside the fuel by using the fission reaction to separate the fission products from the fuel. The fuel, which is preferred to be highly isotopic enriched, is fabricated in beads smaller than the fission product range, immersed in a gentle flowing liquid drain. If this liquid is Lead Bismuth (LBE) the fission products will be lighter, while in Sodium-Potassium (NaK) will be heavier, except for gases. This drain liquid will collect both the fission products and the collision damage, drawing them slow to give time to short lives disintegration chains to take place inside the shielded nuclear reactor area outside the reactor core in a separation unit. While the drain liquid with the fission products is outside the reactor core few choices are available: - To solidify the drain liquid freezing all elements inside and transport the metal in cryogenic conditions to a remote separation unit, or to apply a separation partitioning process online stabilizing and packing the fission products only, or a combination of these two. The radioactivity of this drain liquid is smaller than that of the actual used fuel because it represents the accumulation of a very short period (about 1 month or less) and had enough time to cool down all the short lives. The separation unit on-line with the nuclear reactor is composed of a density separation unit, followed by a phase interface concentration unit which moves out of the LBE the fission products as lighter impurities, and an electrochemical separation unit for the fission products. Further, chemical separation, stabilization processes are applied and the fission products are delivered partitioned on groups of chemical compatible products. Finally the specific waste is about 1 Kg/Gw*day, to which the stabilization products have to be added which increases this mass by 10 times

  19. Biosensors and preparation thereof

    NARCIS (Netherlands)

    2008-01-01

    A low-temp. prepn. method for a biosensor device with a layer of reagent on the sensor surface is disclosed. During manufg. biol. interaction between the biosensor substrate and the reagent layer material is reduced, e.g. by cooling the biosensor substrate and depositing the reagent layer on the

  20. Selective-Reagent-Ionization Mass Spectrometry: New Prospects for Atmospheric Research

    Science.gov (United States)

    Sulzer, Philipp; Jordan, Alfons; Hartungen, Eugen; Hanel, Gernot; Jürschik, Simone; Herbig, Jens; Märk, Lukas; Märk, Tilmann D.

    2014-05-01

    Proton-Transfer-Reaction Mass Spectrometry (PTR-MS), which was introduced to the scientific community in the 1990's, has quickly evolved into a well-established technology for atmospheric research and environmental chemistry [1]. Advantages of PTR-MS are i) high sensitivities of several hundred cps/ppbv, ii) detection limits at or below the pptv level, iii) direct injection sampling (i.e. no sample preparation), iv) response times in the 100 ms regime and v) online quantification. However, one drawback is a somehow limited selectivity, as in case of quadrupole mass filter based instruments only information about nominal m/z are available. In Time-Of-Flight (TOF) mass analyzer based instruments selectivity is drastically increased by a high mass resolution of up to 8000 m/Δm, but e.g. isomers still cannot be separated. In 2009 we introduced an advanced version of PTR-MS, which permits switching the reagent ions from H3O+ to NO+ and O2+, respectively [2]. This novel type of instrumentation was called Selective-Reagent-Ionization Mass Spectrometry (SRI-MS) and has been successfully used to separate isomers, e.g. the biogenic compounds isoprene and 2-methyl-3-buten-2-ol as shown by Karl et al. [3]. Switching the reagent ions dramatically increases selectivity and thus applicability of SRI-MS in atmospheric research. Here we report on the latest results utilizing an even more advanced embodiment of SRI-MS enabling the use of the additional reagent ions Kr+ and Xe+ [4]. With this technology important atmospheric compounds, such as CO2, CO, CH4, O2, etc. can be quantified and selectivity is increased even further. We present comparison data between diesel and gasoline car exhaust gases and quantitative data on indoor air for these compounds, which are not detectable with classical PTR-MS. Additionally, we show very recent examples of isomers which cannot be separated with PTR-MS but can clearly be distinguished with SRI-MS. Finally, we give an overview of ongoing SRI

  1. Perceptions Towards On-line Banking Security: An Empirical Investigation of a Developing Country`s Banking Sector, how secure is On-line Banking

    OpenAIRE

    Bongani Ngwenya; Khanyisa Malufu

    2012-01-01

    The increase in computer crime has led to scepticism about themove made by the banks to introduce on-line banking. Someview this as a noble move which has made the banking systemmore efficient, reliable and secure, while others view it as arisky and insecure way of banking. The aim of this study wasto assess whether on-line banking in the developing countriesis secure or not. The researcher chose a descriptive-quantitativeresearch design. Data was collected using a self constructedquestionnai...

  2. Modification of the mitochondrial sulfonylurea receptor by thiol reagents.

    Science.gov (United States)

    Szewczyk, A; Wójcik, G; Lobanov, N A; Nalecz, M J

    1999-08-19

    The purpose of this study was to investigate the effects exerted by thiol-modifying reagents on themitochondrial sulfonylurea receptor. The thiol-oxidizing agents (timerosal and 5, 5'-dithio-bis(2-nitrobenzoic acid)) were found to produce a large inhibition (70% to 80%) of specific binding of [(3)H]glibenclamide to the beef heart mitochondrial membrane. Similar effects were observed with membrane permeable (N-ethylmaleimide) and non-permeable (mersalyl) thiol modifying agents. Glibenclamide binding was also decreased by oxidizing agents (hydrogen peroxide) but not by reducing agents (reduced gluthatione, dithiothreitol and the 2,3-dihydroxy-1,4-dithiolbutane). The results suggest that intact thiol groups, facing the mitochondrial matrix, are essential for glibenclamide binding to the mitochondrial sulfonylurea receptor. Copyright 1999 Academic Press.

  3. Oxidation of cashew tree gum exudate polysaccharide with TEMPO reagent

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, Pablyana L.R.; Maciel, Jeanny S.; Paula, Regina C.M. de; Feitosa, Judith P.A. [Universidade Federal do Ceara, Fortaleza, CE (Brazil). Dept. de Quimica Organica e Inorganica; Sierakowski, Maria Rita [Universidade Federal do Parana, Curitiba, PR (Brazil). Dept. de Quimica]. E-mail: judith@dqoi.ufc.br

    2007-07-01

    Cashew gum (CG), an exudate polysaccharide from Anacardium occidentale trees, was oxidized with TEMPO reagent and the product (CGOX) characterized by spectroscopic techniques (FTIR and NMR), chromatographic analyses (HPLC and GPC), viscosity measurements and thermal analysis (TGA). The yield of the reaction product was 96%. The uronic acid content in starting gum (7.2 m%) was increased to 36 m%. The degree of oxidation based on free galactose and glucose units was 68%. NMR data show that oxidation occurred preferentially at primary carbons of galactose units. High degradation degree after oxidation was estimated by the difference on the expected and observed {eta}{sub CGOX}/{eta}{sub CG} ratio. The presence of organic and inorganic impurities in the new polyelectrolyte was detected by TGA. A less thermally stable cashew gum is formed after the oxidation with TEMPO based on initial decomposition temperature and IPDT. (author)

  4. Chiral reagents in glycosylation and modification of carbohydrates.

    Science.gov (United States)

    Wang, Hao-Yuan; Blaszczyk, Stephanie A; Xiao, Guozhi; Tang, Weiping

    2018-02-05

    Carbohydrates play a significant role in numerous biological events, and the chemical synthesis of carbohydrates is vital for further studies to understand their various biological functions. Due to the structural complexity of carbohydrates, the stereoselective formation of glycosidic linkages and the site-selective modification of hydroxyl groups are very challenging and at the same time extremely important. In recent years, the rapid development of chiral reagents including both chiral auxiliaries and chiral catalysts has significantly improved the stereoselectivity for glycosylation reactions and the site-selectivity for the modification of carbohydrates. These new tools will greatly facilitate the efficient synthesis of oligosaccharides, polysaccharides, and glycoconjugates. In this tutorial review, we will summarize these advances and highlight the most recent examples.

  5. Oxidation of cashew tree gum exudate polysaccharide with TEMPO reagent

    International Nuclear Information System (INIS)

    Cunha, Pablyana L.R.; Maciel, Jeanny S.; Paula, Regina C.M. de; Feitosa, Judith P.A.; Sierakowski, Maria Rita

    2007-01-01

    Cashew gum (CG), an exudate polysaccharide from Anacardium occidentale trees, was oxidized with TEMPO reagent and the product (CGOX) characterized by spectroscopic techniques (FTIR and NMR), chromatographic analyses (HPLC and GPC), viscosity measurements and thermal analysis (TGA). The yield of the reaction product was 96%. The uronic acid content in starting gum (7.2 m%) was increased to 36 m%. The degree of oxidation based on free galactose and glucose units was 68%. NMR data show that oxidation occurred preferentially at primary carbons of galactose units. High degradation degree after oxidation was estimated by the difference on the expected and observed η CGOX /η CG ratio. The presence of organic and inorganic impurities in the new polyelectrolyte was detected by TGA. A less thermally stable cashew gum is formed after the oxidation with TEMPO based on initial decomposition temperature and IPDT. (author)

  6. Determination of drugs in biological fluids by high-performance liquid chromatography with on-line sample processing.

    Science.gov (United States)

    Oertel, R; Richter, K; Gramatté, T; Kirch, W

    1998-02-27

    An automated two column HPLC system with the new packing material LiChrospher RP-18 ADS (alkyl-diol-silica) was tested for the determination of several drugs and metabolites (talinolol, celiprolol, metoprolol, oxprenolol, triamterene, trimethoprim, tiracizine, articaine, detajmium, ajmaline, lamotrigine) in various biological fluids (serum, urine, intestinal aspirates, supernatants of cell cultures and supernatants after protein denaturation). The method allows the direct injection of biological fluids into a reversed-phase HPLC system and on-line clean-up and sample enrichment by a column-switching technique. Precision, accuracy and sensitivity were similar to conventional assays as described in the literature. With this new method it was possible to measure drug concentrations in various biological fluids without changing the sample preparation procedure. In some cases an additional sample preparation like protein denaturation or solid-phase extraction was advantageous to enhance the sensitivity of the method and the life-time of the ADS column.

  7. On-line determination of anions in pulp mills by capillary electrophoresis (CE); Tehdasoloissa tapahtuva anionien kapillaarielektroforeettinen on-line maeaeritys ja sen hyoedyntaeminen prosessivalvonnassa - MPKY 02

    Energy Technology Data Exchange (ETDEWEB)

    Kokkonen, R; Holmberg, M; Vainikka, V [Finnish Pulp and Paper Research Institute, Espoo (Finland)

    1999-12-31

    The aim of the study was to set-up a process control system for on-line measurement of certain anions. Typical anions which forms precipitates in pulp and paper mills are oxalate, carbonate and sulphate. Thus it is important to develop a continuous process analyzing system to control concentration levels of this anions. For the preliminary tests of continuous determinations of chloride and sulphate anions in tap water a simple on-line system was build in KCL (The Finnish Pulp and Paper Research Institute) and connected to a capillary electroforesis apparatus. In the preliminary tests a chromate buffer (ph = 7.6) was used. Separation of chloride and sulphate was excellent but the stability of buffer was not good enough and it was usable only for few hours. After experimental studies VTT developed a stable capillary electrophoresis method based on mixed amine buffer and this was selected for an on-line method for determination of anions in process waters of the pulp and paper industry. In the preliminary on-line test (r = 20) repeatabilities of migration times of sulphate and chloride with the chromate buffer were < 5 % (RSD) and peak heights < 15 % (RSD). With the mixed amine buffer repeatabilities were better. The preliminary tests showed that it is possible to connect a capillary electrophoresis system to on-line measurements. For the moment no commercial on-line CE apparatus is available. (orig.)

  8. On-line determination of anions in pulp mills by capillary electrophoresis (CE); Tehdasoloissa tapahtuva anionien kapillaarielektroforeettinen on-line maeaeritys ja sen hyoedyntaeminen prosessivalvonnassa - MPKY 02

    Energy Technology Data Exchange (ETDEWEB)

    Kokkonen, R.; Holmberg, M.; Vainikka, V. [Finnish Pulp and Paper Research Institute, Espoo (Finland)

    1998-12-31

    The aim of the study was to set-up a process control system for on-line measurement of certain anions. Typical anions which forms precipitates in pulp and paper mills are oxalate, carbonate and sulphate. Thus it is important to develop a continuous process analyzing system to control concentration levels of this anions. For the preliminary tests of continuous determinations of chloride and sulphate anions in tap water a simple on-line system was build in KCL (The Finnish Pulp and Paper Research Institute) and connected to a capillary electroforesis apparatus. In the preliminary tests a chromate buffer (ph = 7.6) was used. Separation of chloride and sulphate was excellent but the stability of buffer was not good enough and it was usable only for few hours. After experimental studies VTT developed a stable capillary electrophoresis method based on mixed amine buffer and this was selected for an on-line method for determination of anions in process waters of the pulp and paper industry. In the preliminary on-line test (r = 20) repeatabilities of migration times of sulphate and chloride with the chromate buffer were < 5 % (RSD) and peak heights < 15 % (RSD). With the mixed amine buffer repeatabilities were better. The preliminary tests showed that it is possible to connect a capillary electrophoresis system to on-line measurements. For the moment no commercial on-line CE apparatus is available. (orig.)

  9. Architectures drawn / digital models: the Venices (impossible on line

    Directory of Open Access Journals (Sweden)

    Malvina Borgherini

    2011-12-01

    Full Text Available A contemporary city representation talks not only about architecture and landscape but also about the effects that political institutions, cultural traditions and economic enterprises have on the urban community. Methods and ways traditionally used to present the complexity and, at the same time, the personality of a town, or on a smaller scale of one of his monument, are not suitable with the contemporary reality. A very famous panel presented at Venice Biennale in 1976, Aldo Rossi’s «Città Analoga», within real and ideal architectures, ancient monuments and contemporary landscapes, individual and collective memories, human presences and empty spaces, can be taken as an example for the preparation of a new ‘story’ or a new ‘map’ for a city like Venice. The space of a digital model can become a place for discussion and analysis, a place where to see together historical records and projects never realized, where to put subjective and objective visions, which overlap daily and occasional tracks.

  10. On-line interactive virtual experiments on nanoscience

    Science.gov (United States)

    Kadar, Manuella; Ileana, Ioan; Hutanu, Constantin

    2009-01-01

    This paper is an overview on the next generation web which allows students to experience virtual experiments on nano science, physics devices, processes and processing equipment. Virtual reality is used to support a real university lab in which a student can experiment real lab sessions. The web material is presented in an intuitive and highly visual 3D form that is accessible to a diverse group of students. Such type of laboratory provides opportunities for professional and practical education for a wide range of users. The expensive equipment and apparatuses that build the experimental stage in a particular standard laboratory is used to create virtual educational research laboratories. Students learn how to prepare the apparatuses and facilities for the experiment. The online experiments metadata schema is the format for describing online experiments, much like the schema behind a library catalogue used to describe the books in a library. As an online experiment is a special kind of learning object, one specifies its schema as an extension to an established metadata schema for learning objects. The content of the courses, metainformation as well as readings and user data are saved on the server in a database as XML objects.

  11. Commissioning and initial experience with the ALICE on-line

    International Nuclear Information System (INIS)

    Altini, V; Anticic, T; Carena, F; Carena, W; Chapeland, S; Barroso, V Chibante; Costa, F; Divia, R; Fuchs, U; Makhlyueva, I; Roukoutakis, F; Schossmaier, K; Soos, C; Vyvre, P Vande; Haller, B von; Denes, E; Kiss, T

    2010-01-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). A large bandwidth and flexible Data Acquisition System (DAQ) has been designed and deployed to collect sufficient statistics in the short running time available per year for heavy ions and to accommodate very different requirements originated from the 18 sub-detectors. This paper will present the large scale tests conducted to assess the standalone DAQ performances, the interfaces with the other online systems and the extensive commissioning performed in order to be fully prepared for physics data taking. It will review the experience accumulated since May 2007 during the standalone commissioning of the main detectors and the global cosmic runs and the lessons learned from this exposure on the b attle field . It will also discuss the test protocol followed to integrate and validate each sub-detector with the online systems and it will conclude with the first results of the LHC injection tests and startup in September 2008. Several papers of the same conference present in more details some elements of the ALICE DAQ system.

  12. Commissioning and initial experience with the ALICE on-line

    Energy Technology Data Exchange (ETDEWEB)

    Altini, V [INFN, Dipartimento di Fisica dell' Universita and Sezione INFN Bari (Italy); Anticic, T [Ruder Botkovic Institute, Zagreb (Croatia); Carena, F; Carena, W; Chapeland, S; Barroso, V Chibante; Costa, F; Divia, R; Fuchs, U; Makhlyueva, I; Roukoutakis, F; Schossmaier, K; Soos, C; Vyvre, P Vande; Haller, B von [CERN, Physics department, Geneva (Switzerland); Denes, E; Kiss, T, E-mail: pierre.vande.vyvre@cern.c [KFKI Research Institute for Particle and Nuclear Physics, Budapest (Hungary)

    2010-04-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). A large bandwidth and flexible Data Acquisition System (DAQ) has been designed and deployed to collect sufficient statistics in the short running time available per year for heavy ions and to accommodate very different requirements originated from the 18 sub-detectors. This paper will present the large scale tests conducted to assess the standalone DAQ performances, the interfaces with the other online systems and the extensive commissioning performed in order to be fully prepared for physics data taking. It will review the experience accumulated since May 2007 during the standalone commissioning of the main detectors and the global cosmic runs and the lessons learned from this exposure on the {sup b}attle field{sup .} It will also discuss the test protocol followed to integrate and validate each sub-detector with the online systems and it will conclude with the first results of the LHC injection tests and startup in September 2008. Several papers of the same conference present in more details some elements of the ALICE DAQ system.

  13. Commissioning and initial experience with the ALICE on-line

    Science.gov (United States)

    Altini, V.; Anticic, T.; Carena, F.; Carena, W.; Chapeland, S.; Chibante Barroso, V.; Costa, F.; Dénes, E.; Divià, R.; Fuchs, U.; Kiss, T.; Makhlyueva, I.; Roukoutakis, F.; Schossmaier, K.; Soós, C.; Vande Vyvre, P.; von Haller, B.; ALICE Collaboration

    2010-04-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). A large bandwidth and flexible Data Acquisition System (DAQ) has been designed and deployed to collect sufficient statistics in the short running time available per year for heavy ions and to accommodate very different requirements originated from the 18 sub-detectors. This paper will present the large scale tests conducted to assess the standalone DAQ performances, the interfaces with the other online systems and the extensive commissioning performed in order to be fully prepared for physics data taking. It will review the experience accumulated since May 2007 during the standalone commissioning of the main detectors and the global cosmic runs and the lessons learned from this exposure on the "battle field". It will also discuss the test protocol followed to integrate and validate each sub-detector with the online systems and it will conclude with the first results of the LHC injection tests and startup in September 2008. Several papers of the same conference present in more details some elements of the ALICE DAQ system.

  14. Textile wastewater reuse after additional treatment by Fenton's reagent.

    Science.gov (United States)

    Ribeiro, Marília Cleto Meirelles; Starling, Maria Clara V M; Leão, Mônica Maria Diniz; de Amorim, Camila Costa

    2017-03-01

    This study verifies textile wastewater reuse treated by the conventional activated sludge process and subjected to further treatment by advanced oxidation processes. Three alternative processes are discussed: Fenton, photo-Fenton, and UV/H 2 O 2 . Evaluation of treatments effects was based on factorial experiment design in which the response variables were the maximum removal of COD and the minimum concentration of residual H 2 O 2 in treated wastewater. Results indicated Fenton's reagent, COD/[H 2 O 2 ]/[Fe 2+ ] mass ratio of 1:2:2, as the best alternative. The selected technique was applied to real wastewater collected from a conventional treatment plant of a textile mill. The quality of the wastewater before and after the additional treatment was monitored in terms of 16 physicochemical parameters defined as suitable for the characterization of waters subjected to industrial textile use. The degradation of the wastewater was also evaluated by determining the distribution of its molecular weight along with the organic matter fractionation by ultrafiltration, measured in terms of COD. Finally, a sample of the wastewater after additional treatment was tested for reuse at pilot scale in order to evaluate the impact on the quality of dyed fabrics. Results show partial compliance of treated wastewater with the physicochemical quality guidelines for reuse. Removal and conversion of high and medium molecular weight substances into low molecular weight substances was observed, as well as the degradation of most of the organic matter originally present in the wastewater. Reuse tests indicated positive results, confirming the applicability of wastewater reuse after the suggested additional treatment. Graphical abstract Textile wastewater samples after additional treatment by Fenton's reagent, photo-Fenton and H 2 O 2 /UV tested in different conditions.

  15. Action Intentions: Action Influences Both On-Line Perception and Off-Line Representation

    Directory of Open Access Journals (Sweden)

    C Kirtley

    2014-08-01

    Full Text Available Given that one role of vision is to gather information for upcoming tasks, previous studies have investigated whether the preparation for action affects visual behaviour. The current studies aimed to determine if such influences on visual selection would also influence the formation of subsequent memory representations. Two experiments were conducted- in the first, participants' action intentions towards a scene were manipulated by the performance of different grasping postures as they observed the scene. This was followed by a memory test for the objects presented. Participants' eye movements were affected by their action intention, so that performing a power grip led to significantly longer fixation durations on power grip compatible objects. In contrast, memory for the objects and their properties was not affected by the action. Our second study required participants to make the action posture during the recall phase. No effect on eye movements was found, but recall was affected, with a particular advantage for recall of the position of grip-compatible objects. Previous studies have shown that action intentions can affect the on-line perception of objects. The current study suggests this may not extend to off-line representations if they are accessed after the action has been completed or abandoned. However, the recall of information may be affected if gestures are formed during retrieval. Memory representations may not be tailored specifically to an action, but actions can still affect the recall of information.

  16. Graded Approach to the Development of a Contingency Plan for On-Line Maintenance

    International Nuclear Information System (INIS)

    Chang, Hee Seung; Kim, Jung Wun; Song, Tae Young

    2012-01-01

    Many utilities perform preventive maintenance for safety systems during power operation to improve equipment reliability so as to focus on the work activities more easily and improve the quality of maintenance. Such a strategy can also reduce outage work activities, thus allowing resources to be utilized effectively. Preventive maintenance during power operation, known as on-line maintenance (OLM), requires an assessment and mitigation of risk, which can increase owing to out-of-service safety systems. One of the mitigation action plans is a contingency plan. EPRI recommends the development of a contingency plan for all planned system outages which include factors that strongly affect safety. The Korea Hydro and Nuclear Power Company (KHNP) undertook the preventive maintenance of the Essential Chilled Water System (ECWS) of a Westinghouse plant as a pilot OLM implementation. During the preparation of the work activities, a contingency plan was a pertinent issue during the discussions with regulators, especially regarding the scope and depth of the plan. This paper discusses the purpose of a contingency plan, including as examples some cases of US utilities, and proposes a graded approach to develop a contingency plan for OLM in consideration of the risks

  17. On-line double isotope dilution laser ablation inductively coupled plasma mass spectrometry for the quantitative analysis of solid materials.

    Science.gov (United States)

    Fernández, Beatriz; Rodríguez-González, Pablo; García Alonso, J Ignacio; Malherbe, Julien; García-Fonseca, Sergio; Pereiro, Rosario; Sanz-Medel, Alfredo

    2014-12-03

    We report on the determination of trace elements in solid samples by the combination of on-line double isotope dilution and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method requires the sequential analysis of the sample and a certified natural abundance standard by on-line IDMS using the same isotopically-enriched spike solution. In this way, the mass fraction of the analyte in the sample can be directly referred to the certified standard so the previous characterization of the spike solution is not required. To validate the procedure, Sr, Rb and Pb were determined in certified reference materials with different matrices, including silicate glasses (SRM 610, 612 and 614) and powdered samples (PACS-2, SRM 2710a, SRM 1944, SRM 2702 and SRM 2780). The analysis of powdered samples was carried out both by the preparation of pressed pellets and by lithium borate fusion. Experimental results for the analysis of powdered samples were in agreement with the certified values for all materials. Relative standard deviations in the range of 6-21% for pressed pellets and 3-21% for fused solids were obtained from n=3 independent measurements. Minimal sample preparation, data treatment and consumption of the isotopically-enriched isotopes are the main advantages of the method over previously reported approaches. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Comparing On-Line to In-Person Course Delivery: An Empirical Study

    OpenAIRE

    Jammie Price; Leslie Hossfeld

    2007-01-01

    Web-based technologies have been used in the classroom for over 15 years, including websites, email, listserves, library reserves, and text books. Among these options, social scientists range widely in their web usage – from simply posting syllabi on-line to delivering a course fully on-line in asynchronous learning networks. Use of web-based technology for instructional purposes is increasing, as is enrollment in distance education courses and on-line course offerings. Many administrators ...

  19. A review of reagents for fluorescence microscopy of cellular compartments and structures, part I: BacMam labeling and reagents for vesicular structures.

    Science.gov (United States)

    Dolman, Nick J; Kilgore, Jason A; Davidson, Michael W

    2013-07-01

    Fluorescent labeling of vesicular structures in cultured cells, particularly for live cells, can be challenging for a number of reasons. The first challenge is to identify a reagent that will be specific enough where some structures have a number of potential reagents and others very few options. The emergence of BacMam constructs has allowed more easy-to-use choices. Presented here is a discussion of BacMam constructs as well as a review of commercially-available reagents for labeling vesicular structures in cells, including endosomes, peroxisomes, lysosomes, and autophagosomes, complete with a featured reagent for each structure, recommended protocol, troubleshooting guide, and example image. © 2013 by John Wiley & Sons, Inc.

  20. On-Line Booking Policies and Competitive Analysis of Medical Examination in Hospital

    Directory of Open Access Journals (Sweden)

    Li Luo

    2014-01-01

    Full Text Available From the on-line point, we consider the hospital’s medical examination appointment problem with hierarchical machines. This approach eliminates the need for both demand forecasts and a risk-neutrality assumption. Due to different unit revenue, uncertain demand, and arrival of patients, we design on-line booking policies for two kinds of different situations from the perspective of on-line policy and competitive analysis. After that, we prove the optimal competitive ratios. Through numerical examples, we compare advantages and disadvantages between on-line policies and traditional policies, finding that there is different superiority for these two policies under different arrival sequences.