WorldWideScience

Sample records for reagent preparation on-line

  1. A dedicated on-line system for the preparation and validation of standard beads in XRF analysis

    International Nuclear Information System (INIS)

    Yamamoto, Yasuyuki; Ogasawara, Noriko; Nakata, Akio; Shoji, Shizuko.

    1995-01-01

    A dedicated on-line system in X-ray Fluorescence (XRF) analysis with glass-bead method was developed in which preparation of standard beads was automated including proper choice of reagents, assignment of bead compositions and validation of the prepared beads. This system features: a. Fundamental Parameter (FP) Method for validation of standard beads. b. An original database of high purity reagents for standards. c. Automatic calculation of suitable composition for each standard bead, by giving a range for each element and the number of standard beads. 1) The calculation is based on random numbers, and makes a random assignment of composition for each bead. 2) The calculation results are automatically stored in a computer as a condition file for quantitative analysis. 3) An amount of a material for a standard mixture is corrected if a valence or a chemical compound for an analysis element is different from that of the standard material in the database. In order to realize these features, many high purity reagents were examined for their purities and other characteristics to test a suitability to use for a standard material, and a software for on-line processings was originally developed. (author)

  2. Optimization in the preparation of the YBa2Cu3O7-δ compound using BaCO3 and BaO2 reagents

    International Nuclear Information System (INIS)

    Bustamante D, A.; Flores S, J.

    2004-01-01

    The traditional superconductor YBa 2 Cu 3 O 7-δ (Y123) has an orthorhombic crystalline structure with spatial group Pmmm and its critical temperature is 90K. The literature reports the use of reagent BaCO 3 for the preparation by the solid state reaction which requires one calcination and two thermal treatments in oxygen flow at 950 o C. In this work we report the comparison in the preparation of Y123 using the BaO 2 reagent as another possibility for preparation; in this case we have used only two thermal treatments in oxygen flow at 950 o C; therefore reducing the costs in preparation. The powder XRD pattern of samples prepared with BaO 2 confirm a well crystallized phase an the diffraction lines of the main phase can be indexed with an orthorhombic unit cell. The ac susceptibility measurement in the range 5-100 K using a Quantum Design (SQUID) magnetometer for two samples confirms the superconductor behavior with critical temperature Tc ≅ 91 K. The critical temperatures for these systems were found taken account the derivatives of the susceptibility curves. Scanning Electron Microscopy (SEM) confirms the good behavior of the grains corresponding to both methods. (orig.)

  3. Characterization of Reagent Pencils for Deposition of Reagents onto Paper-Based Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Cheyenne H. Liu

    2017-08-01

    Full Text Available Reagent pencils allow for solvent-free deposition of reagents onto paper-based microfluidic devices. The pencils are portable, easy to use, extend the shelf-life of reagents, and offer a platform for customizing diagnostic devices at the point of care. In this work, reagent pencils were characterized by measuring the wear resistance of pencil cores made from polyethylene glycols (PEGs with different molecular weights and incorporating various concentrations of three different reagents using a standard pin abrasion test, as well as by measuring the efficiency of reagent delivery from the pencils to the test zones of paper-based microfluidic devices using absorption spectroscopy and digital image colorimetry. The molecular weight of the PEG, concentration of the reagent, and the molecular weight of the reagent were all found to have an inverse correlation with the wear of the pencil cores, but the amount of reagent delivered to the test zone of a device correlated most strongly with the concentration of the reagent in the pencil core. Up to 49% of the total reagent deposited on a device with a pencil was released into the test zone, compared to 58% for reagents deposited from a solution. The results suggest that reagent pencils can be prepared for a variety of reagents using PEGs with molecular weights in the range of 2000 to 6000 g/mol.

  4. Technical Report (Final): Development of Solid State Reagents for Preparing Radiolabeled Imaging Agents

    Energy Technology Data Exchange (ETDEWEB)

    Kabalka, George W

    2011-05-20

    The goal of this research was on the development of new, rapid, and efficient synthetic methods for incorporating short-lived radionuclides into agents of use in measuring dynamic processes. The initial project period (Year 1) was focused on the preparation of stable, solid state precursors that could be used to efficiently incorporate short-lived radioisotopes into small molecules of use in biological applications (environmental, plant, and animal). The investigation included development and evaluation of new methods for preparing carbon-carbon and carbon-halogen bonds for use in constructing the substrates to be radiolabeled. The second phase (Year 2) was focused on developing isotope incorporation techniques using the stable, boronated polymeric precursors. The final phase (Year 3), was focused on the preparation of specific radiolabeled agents and evaluation of their biodistribution using micro-PET and micro-SPECT. In addition, we began the development of a new series of polymeric borane reagents based on polyethylene glycol backbones.

  5. [An evaluation of the China-made HIV antibody test reagents].

    Science.gov (United States)

    Zheng, X W; Zhu, D

    1990-06-01

    This paper reports the results of the evaluation of the China-made HIV antibody screening test reagents, including the IF and IE reagents prepared by the Institute of Virology, CAPM, the ELISA reagent prepared by the Shanghai Institute of Biological Products. Based on the results, the sensitivities of the IF and IE are from 91.2% to 96.9%; the specificities, from 94.6% to 97.3%. Due to the low HIV prevalence in China, the predictive values of negative of these reagents are up to 100%; but the predictive values of positive are very low. It is suggested that these reagents can be used for HIV antibody screen testing in China. The package of some reagents should be improved, the price of some reagents should be decreased.

  6. A Catalyst-Free Amination of Functional Organolithium Reagents by Flow Chemistry.

    Science.gov (United States)

    Kim, Heejin; Yonekura, Yuya; Yoshida, Jun-Ichi

    2018-04-03

    Reported is the electrophilic amination of functional organolithium intermediates with well-designed aminating reagents under mild reaction conditions using flow microreactors. The aminating reagents were optimized to achieve efficient C-N bond formation without using any catalyst. The electrophilic amination reactions of functionalized aryllithiums were successfully conducted under mild reaction conditions, within 1 minute, by using flow microreactors. The aminating reagent was also prepared by the flow method. Based on stopped-flow NMR analysis, the reaction time for the preparation of the aminating reagent was quickly optimized without the necessity of work-up. Integrated one-flow synthesis consisting of the generation of an aryllithium, the preparation of an aminating reagent, and their combined reaction was successfully achieved to give the desired amine within 5 minutes of total reaction time. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Diagnostic reagent system

    International Nuclear Information System (INIS)

    1976-01-01

    A solid phase reagent for use in radioimmunoassay of antigens and antibodies is described. The reagent is prepared by mixing specific antibody or radiolabeled antigen with polyethylene glycol (4000-6000) and gamma globulin in a buffer at pH 4-10 and lyophilizing, the antigens being thyroxine, triiodothyronine, digoxin and digitoxin (1-1000 μCi 125 I/μg). The buffer consists of a 0.08 molar sodium barbital solution containing 0.1% of ox-serum albumin and 0.35% of 8-anilino-1-naftalene sulfonic acid

  8. Spectrophotometric determination of metformin in pharmaceutical preparations, serum and urine using benzoin as derivatizing reagent

    International Nuclear Information System (INIS)

    Alamgir, M.; Hayat, A.

    2014-01-01

    A simple and selective spectrophotometric procedure is described for the determination of Metformin based on derivatization with benzoin. The Beers law was obeyed with 2.50-12.50 meu mol L-1 at 290 nm with coefficient of determination (r2) 0.997. The experimental conditions in term of pH, reaction time and temperature, and addition of derivatizing reagent were examined. The pure metformin-benzoin derivative was prepared and characterized by FT-IR and mass spectroscopic techniques. The method was applied for the determination of metformin from pharmaceutical preparations and serum and urine of volunteers after spiking with metformin. The results were checked by standard addition method. A number of pharmaceutical additives and serum or urine matrix did not affect the determination of metformin. (author)

  9. Stability of Loop-Mediated Isothermal Amplification (LAMP) Reagents and its Amplification Efficiency on Crude Trypanosome DNA Templates

    OpenAIRE

    Thekisoe, Oriel M. M; Bazie, Raoul S. B; Coronel-Servian, Andrea M; Sugimoto, Chihiro; Kawazu, Shin-ichiro; Inoue, Noboru

    2009-01-01

    This study evaluated the stability of LAMP reagents when stored at 25C and 37C, and also assessed its detection efficiency on different DNA template preparations. Accordingly, LAMP using reagents stored at 25C and 37C amplified DNA of in vitro cultured T. b. brucei (GUTat 3.1) from day 1 to day 15 of reagent storage. There were no significant differences (P>0.05) in detection sensitivity of LAMP among the reagents stored at 25C, 37C and –20C (recommended storage temperature). LAMP usin...

  10. 21 CFR 864.4020 - Analyte specific reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Analyte specific reagents. 864.4020 Section 864.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Specimen Preparation Reagents § 864.4020 Analyte specific...

  11. 21 CFR 864.4010 - General purpose reagent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false General purpose reagent. 864.4010 Section 864.4010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Specimen Preparation Reagents § 864.4010 General purpose...

  12. Preparation and optimization of ammonium phospho-molybdate reagent (FMA) (NH4)3[PMo12O40

    International Nuclear Information System (INIS)

    Cruz C, W.; Mallaupoma G, M.; Rodriguez C, G.

    1996-01-01

    The characteristics of low and medium level liquid radioactive waste produced in the Nuclear Research Center RACSO was identified, taking into account the philosophy of radiological safety. In liquid wastes, Cs-137 radionuclide could be present, which is important for radio-sanitary considerations. Its half life is 30 years. In the radioactive waste management, it is possible to separate Cs-137 by using a chemical treatment. One of the used chemical reagents is ammonium phospho-molybdate (FMA). The preparation method and the production optimization of FMA in the laboratory scale for its use as an economical reagent in the separation of Cs-137 radionuclide is shown in this paper. The objective is to get the higher decontamination factor and to reduce the volume containing the higher activity of the Cs-137 radionuclide. (authors). 4 refs., 2 tabs

  13. N-tritioacetoxyphthalimide: A new high specific activity tritioacetylating reagent

    International Nuclear Information System (INIS)

    Saljoughian, M.; Morimoto, Hiromi; Than, Chit

    1996-01-01

    The authors' aim was to develop a nonvolatile, stable, and facile tritioacetylating reagent and to demonstrate its use on simple peptides. Accordingly, the authors made the synthesis of high specific activity N-(tritioacetoxy) derivatives of succinimide, phthalimide, and naphthalimide a major focus. As the preferred approach, N-(tritioacetoxy)phthalimide was prepared by radical dehalogenation of N-(iodoacetoxy)phthalimide using high specific activity tributyltin tritide. This tritiated acetylation reagent was characterized by 3 H and 1 H NMR spectroscopy and by radio-HPLC. Efficacy of the reagent was investigated by tritioacetylation of several peptides at their N-terminal amino group. 26 refs., 1 fig

  14. Rapid reagent-less on-line H2O2 quantification in alkaline semiconductor etching solution, Part 2: Nephelometry application.

    Science.gov (United States)

    Zlatev, Roumen; Stoytcheva, Margarita; Valdez, Benjamin

    2018-03-01

    A simple and rapid reagent less nephelometric method for on-line H 2 O 2 quantification in semiconductors etching solutions was developed, optimized, characterized and validated. The intensity of the light scattered by the oxygen gas suspension resulted from H 2 O 2 catalytic decomposition by immobilized MnO 2 was registered as analytical response. The influences of the light wave length, the agitation rate, the temperature and the catalyst surface area on the response amplitude were studied and optimization was done. The achieved linear concentration range from 10 to 150mmolL -1 at 0.9835 calibration curve correlation coefficient, precision from 3.65% to 0.95% and response time from 35 to 20s respectively, at sensitivity of 8.01µAmmol -1 L and LOD of 2.9mmolL -1 completely satisfy the semiconductor industry requirements. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Preparation of submicron-sized spherical particles of gold using laser-induced melting in liquids and low-toxic stabilizing reagent

    International Nuclear Information System (INIS)

    Tsuji, T.; Higashi, Y.; Tsuji, M.; Ishikawa, Y.; Koshizaki, N.

    2015-01-01

    Highlights: • Submicron-sized spherical particles of gold were prepared using laser irradiation for the source gold nanoparticles stabilized by NaCl. • The source gold nanoparticles agglomeration was controlled both by the NaCl concentration of and by laser irradiation. • The formation process and the laser-fluence dependence of the particle size of gold nanoparticles in NaCl solutions differs from those in citrate solutions. • We revealed that properties of ligands are significantly important to prepare submicron-sized spherical particles and to control their size. - Abstract: Laser-induced melting in liquids (LIML) was applied to prepare spherical submicron-sized particles of gold (AuSMPs) from gold nanoparticles (AuNPs) stabilized using NaCl. Because undesirable byproducts, which might be generated when organic reagents such as citrate are used as the stabilizing reagent, are not generated from NaCl by laser irradiation, AuSMPs fabricated from AuNPs stabilized by NaCl will be low toxic. The AuSMPs were obtained by laser irradiation of the source AuNPs in NaCl solutions stabilized by NaCl at the proper concentration. Similar to the preparation of AuSMPs from AuNPs stabilized by citrate, the agglomeration of the source AuNPs, which is necessary to obtain AuSMPs, was controlled both by the NaCl concentration and by laser irradiation. However, the formation process and the laser-fluence dependence of the particle size of AuSMPs differed for various NaCl solutions and citrate solutions

  16. Determination of tin(II) in reagents for radiopharmaceuticals

    International Nuclear Information System (INIS)

    Morosanova, E.I.; Loginova, K. A.; Epstein, N.B.

    2003-01-01

    The goal of this work is to elaborate a procedure for rapid and simple determination of tin(II) in reagents for preparation of radiopharmaceuticals based on a system albumin-Tc-99m. Original test tools for the determination of various analytes have been suggested in our lab based on the use of small glass tubes (1-2 mm i.d. - 50-70 mm) filled with indicator powders containing suitable immobilized chromogenic reagents. An analytical signal (a length of colored zone which is proportional to the concentration of an analyte) is detected after a sample passing through the indicator tube. Heteropoly compounds are well-known analytical reagents for a photometric determination of various reductants. For elaboration of indicator tubes abilities of Mo,P-heteropoly compounds to give deeply colored blue compounds after reduction were used. (authors)

  17. Stability of Loop-Mediated Isothermal Amplification (LAMP) reagents and its amplification efficiency on crude trypanosome DNA templates.

    Science.gov (United States)

    Thekisoe, Oriel M M; Bazie, Raoul S B; Coronel-Servian, Andrea M; Sugimoto, Chihiro; Kawazu, Shin-Ichiro; Inoue, Noboru

    2009-04-01

    This study evaluated the stability of LAMP reagents when stored at 25 degrees C and 37 degrees C, and also assessed its detection efficiency on different DNA template preparations. Accordingly, LAMP using reagents stored at 25 degrees C and 37 degrees C amplified DNA of in vitro cultured T. b. brucei (GUTat 3.1) from day 1 to day 15 of reagent storage. There were no significant differences (P>0.05) in detection sensitivity of LAMP among the reagents stored at 25 degrees C, 37 degrees C and -20 degrees C (recommended storage temperature). LAMP using the reagents stored at above-mentioned temperatures amplified serially diluted DNAs (genomic DNA extracted by phenol-chloroform method, FTA card and hemolysed blood) of T. b. gambiense (IL2343) with high sensitivity. Reactions were conducted on the reagents stored from 1 day to 30 days. LAMP detection sensitivity was poor when fresh blood as DNA template was added directly into reactive solution. Results of this study demonstrated that LAMP has the potential to be used in field conditions for diagnosis of trypanosome infections without being affected by ambient temperatures of tropical and sub-tropical countries where trypanosomosis is endemic.

  18. Review Article: Toxic Effects of Some Reagents Used in Electron ...

    African Journals Online (AJOL)

    Ultrathin sections prepared for electron microscopy and histochemistry are indispensable in cytological, histological and histochemical studies. The paper discusses the various reagents used in these fields of study. Unfortunately, these reagents and chemicals are hazardous to health. There is wisdom in informing the ...

  19. A Field-Portable Cell Analyzer without a Microscope and Reagents.

    Science.gov (United States)

    Seo, Dongmin; Oh, Sangwoo; Lee, Moonjin; Hwang, Yongha; Seo, Sungkyu

    2017-12-29

    This paper demonstrates a commercial-level field-portable lens-free cell analyzer called the NaviCell (No-stain and Automated Versatile Innovative cell analyzer) capable of automatically analyzing cell count and viability without employing an optical microscope and reagents. Based on the lens-free shadow imaging technique, the NaviCell (162 × 135 × 138 mm³ and 1.02 kg) has the advantage of providing analysis results with improved standard deviation between measurement results, owing to its large field of view. Importantly, the cell counting and viability testing can be analyzed without the use of any reagent, thereby simplifying the measurement procedure and reducing potential errors during sample preparation. In this study, the performance of the NaviCell for cell counting and viability testing was demonstrated using 13 and six cell lines, respectively. Based on the results of the hemocytometer ( de facto standard), the error rate (ER) and coefficient of variation (CV) of the NaviCell are approximately 3.27 and 2.16 times better than the commercial cell counter, respectively. The cell viability testing of the NaviCell also showed an ER and CV performance improvement of 5.09 and 1.8 times, respectively, demonstrating sufficient potential in the field of cell analysis.

  20. Spectrophotometric determination of tannins by phosphotungstic-phosphomolybdic reagent

    Energy Technology Data Exchange (ETDEWEB)

    Reicher, F; Sierakowski, M R; Correa, J B.C. [Parana Univ., Curitiba (Brazil). Dept. de Bioquimica

    1981-01-01

    There are several colorimetric techniques to determine tannins in plant extracts. One frequently used is the Folin method (phosphotungstic acid reagent) that procedures a blue color with phenolic compounds. However, this coloured complex is unstable. With the Folin-Ciocalteau reagent, used in protein determination (Lowry et al. J.B.C. 193: 265, 1951) good results were obtained, even in the absence of cooper solution. Using phosphotungstic-phosphomolybdic reagent (Folin-Denis), it was obtained maximum color with 1,0 ml of the reagent in 20 minutes, after the additon of 10 ml 20% sodium carbonate solution. Tannins samples containing 10 to 200 ..mu..g/ml were analysed. Absorbances are determined at 720 or 600 nm. Tannins of commercial preparations from Acacia negra were analysed by the phosphotungstic-phosphomolybdic reagent before (A) and after (B) treatment with chromate hyde powder. By this procedure hydrolysible tannins were determined (A-B).

  1. Spectrophotometric determination of tannins by phosphotungstic-phosphomolibdic reagent

    International Nuclear Information System (INIS)

    Reicher, F.; Sierakowski, M.R.; Correa, J.B.C.

    1981-01-01

    There are several colorimetric techniques to determine tannins in plant extracts. One frequently used is the Folin method (phosphotungstic acid reagent) that procedures a blue color with phenolic compounds. However, this coloured complex is unstable. With the Folin-Ciocalteau reagent, used in protein determination (Lowry et al. J.B.C. 193: 265, 1951) good results were obtained, even in the absence of cooper solution. Using phosphotungstic-phosphomolibdic reagent (Folin-Denis), it was obtained maximum color with 1,0 ml of the reagent in 20 minutes, after the adition of 10 ml 20% sodium carbonate solution. Tannins samples containing 10 to 200 μg/ml were analysed. Absorbances are determined at 720 or 600 nm. Tannins of commercial preparations from Acacia negra were analysed by the phosphotungstic-phosphomolibdic reagent before (A) and after (B) treatment with chromate hyde powder. By this procedure hydrolysible tannins were determined (A-B). (Author) [pt

  2. Antiproliferative effects of the readily extractable fractions prepared from various citrus juices on several cancer cell lines.

    Science.gov (United States)

    Kawaii, S; Tomono, Y; Katase, E; Ogawa, K; Yano, M

    1999-07-01

    To eliminate the masking effect by flavonoid glycosides, which comprise approximately 70% of conventionally prepared sample, the readily extractable fraction from Citrus juice, which was prepared by adsorbing on HP-20 resin and eluting with ethanol and acetone from the resin, was subjected to antiproliferative tests against several cancer cell lines. Screening of 34 Citrus juices indicated that King (Citrus nobilis) strongly inhibited proliferation of all cancer cell lines examined. Sweet lime and Kabuchi inhibited three of the four cancer cell lines. In contrast, these samples were substantially less cytotoxic toward normal human cell lines.

  3. Inventory management and reagent supply for automated chemistry.

    Science.gov (United States)

    Kuzniar, E

    1999-08-01

    Developments in automated chemistry have kept pace with developments in HTS such that hundreds of thousands of new compounds can be rapidly synthesized in the belief that the greater the number and diversity of compounds that can be screened, the more successful HTS will be. The increasing use of automation for Multiple Parallel Synthesis (MPS) and the move to automated combinatorial library production is placing an overwhelming burden on the management of reagents. Although automation has improved the efficiency of the processes involved in compound synthesis, the bottleneck has shifted to ordering, collating and preparing reagents for automated chemistry resulting in loss of time, materials and momentum. Major efficiencies have already been made in the area of compound management for high throughput screening. Most of these efficiencies have been achieved with sophisticated library management systems using advanced engineering and data handling for the storage, tracking and retrieval of millions of compounds. The Automation Partnership has already provided many of the top pharmaceutical companies with modular automated storage, preparation and retrieval systems to manage compound libraries for high throughput screening. This article describes how these systems may be implemented to solve the specific problems of inventory management and reagent supply for automated chemistry.

  4. Alkylation of pyridines at their 4-positions with styrenes plus yttrium reagent or benzyl Grignard reagents.

    Science.gov (United States)

    Mizumori, Tomoya; Hata, Takeshi; Urabe, Hirokazu

    2015-01-02

    A new regioselective alkylation of pyridines at their 4-position was achieved with styrenes in the presence of yttrium trichloride, BuLi, and diisobutylaluminium hydride (DIBAL-H) in THF. Alternatively, similar products were more simply prepared from pyridines and benzyl Grignard reagents. These reactions are not only a useful preparation of 4-substituted pyridines but are also complementary to other relevant reactions usually giving 2-substituted pyridines. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. An International Standard for specifying the minimum potency of anti-D blood-grouping reagents: evaluation of a candidate preparation in an international collaborative study

    NARCIS (Netherlands)

    Thorpe, S. J.; Fox, B.; Heath, A. B.; Scott, M.; de Haas, M.; Kochman, S.; Padilla, A.

    2006-01-01

    The aim of this study was to evaluate a lyophilized monoclonal immunoglobulin M (IgM) anti-D preparation for use as an International Standard to specify a recommended minimum acceptable potency of anti-D blood-grouping reagents. The candidate International Standard (99/836) for specifying the

  6. Genotoxicity assessment of membrane concentrates of landfill leachate treated with Fenton reagent and UV-Fenton reagent using human hepatoma cell line

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Guifang [Department of Chemistry, Jinan University, Guangzhou 510632 (China); Lu, Gang [Key Laboratory of Water/Soil Toxic Pollutants Control and Bioremediation of Guangdong Higher Education Institutes, Department of Environmental Engineering, Jinan University, Guangzhou 510632 (China); Yin, Pinghe, E-mail: tyinph@jnu.edu.cn [Research Center of Analysis and Test, Jinan University, Guangzhou 510632 (China); Zhao, Ling, E-mail: zhaoling@jnu.edu.cn [Key Laboratory of Water/Soil Toxic Pollutants Control and Bioremediation of Guangdong Higher Education Institutes, Department of Environmental Engineering, Jinan University, Guangzhou 510632 (China); Jimmy Yu, Qiming [Griffith School of Engineering, Griffith University, Nathan Campus, Brisbane, Queensland 4111 (Australia)

    2016-04-15

    Highlights: • Membrane concentrates have a threat to human health and environment. • Untreated membrane concentrates induces cytotoxic and genotoxic to HepG2 cells. • Both methods were effective method for degradation of BPA and NP in concentrates. • Both methods were efficient in reducing genotoxic effects of concentrates. • UV-Fenton reagent had higher removal efficiency and provides toxicological safety. - Abstract: Membrane concentrates of landfill leachates contain organic and inorganic contaminants that could be highly toxic and carcinogenic. In this paper, the genotoxicity of membrane concentrates before and after Fenton and UV-Fenton reagent was assessed. The cytotoxicity and genotoxicity was determined by using the methods of methyltetrazolium (MTT), cytokinesis-block micronucleus (CBMN) and comet assay in human hepatoma cells. MTT assay showed a cytotoxicity of 75% after 24 h of exposure to the highest tested concentration of untreated concentrates, and no cytotoxocity for UV-Fenton and Fenton treated concentrates. Both CBMN and comet assays showed increased levels of genotoxicity in cells exposed to untreated concentrates, compared to those occurred in cells exposed to UV-Fenton and Fenton reagent treated concentrates. There was no significant difference between negative control and UV-Fenton treated concentrates for micronucleus and comet assay parameters. UV-Fenton and Fenton treatment, especially the former, were effective methods for degradation of bisphenol A and nonylphenol in concentrates. These findings showed UV-Fenton and Fenton reaction were effective methods for treatment of such complex concentrates, UV-Fenton reagent provided toxicological safety of the treated effluent, and the genotoxicity assays were found to be feasible tools for assessment of toxicity risks of complex concentrates.

  7. Genotoxicity assessment of membrane concentrates of landfill leachate treated with Fenton reagent and UV-Fenton reagent using human hepatoma cell line

    International Nuclear Information System (INIS)

    Wang, Guifang; Lu, Gang; Yin, Pinghe; Zhao, Ling; Jimmy Yu, Qiming

    2016-01-01

    Highlights: • Membrane concentrates have a threat to human health and environment. • Untreated membrane concentrates induces cytotoxic and genotoxic to HepG2 cells. • Both methods were effective method for degradation of BPA and NP in concentrates. • Both methods were efficient in reducing genotoxic effects of concentrates. • UV-Fenton reagent had higher removal efficiency and provides toxicological safety. - Abstract: Membrane concentrates of landfill leachates contain organic and inorganic contaminants that could be highly toxic and carcinogenic. In this paper, the genotoxicity of membrane concentrates before and after Fenton and UV-Fenton reagent was assessed. The cytotoxicity and genotoxicity was determined by using the methods of methyltetrazolium (MTT), cytokinesis-block micronucleus (CBMN) and comet assay in human hepatoma cells. MTT assay showed a cytotoxicity of 75% after 24 h of exposure to the highest tested concentration of untreated concentrates, and no cytotoxocity for UV-Fenton and Fenton treated concentrates. Both CBMN and comet assays showed increased levels of genotoxicity in cells exposed to untreated concentrates, compared to those occurred in cells exposed to UV-Fenton and Fenton reagent treated concentrates. There was no significant difference between negative control and UV-Fenton treated concentrates for micronucleus and comet assay parameters. UV-Fenton and Fenton treatment, especially the former, were effective methods for degradation of bisphenol A and nonylphenol in concentrates. These findings showed UV-Fenton and Fenton reaction were effective methods for treatment of such complex concentrates, UV-Fenton reagent provided toxicological safety of the treated effluent, and the genotoxicity assays were found to be feasible tools for assessment of toxicity risks of complex concentrates.

  8. Application of flotational reagents obtained from coke-industry byproducts

    Energy Technology Data Exchange (ETDEWEB)

    N.I. Nikitin; I.N. Nikitin; N.I. Toporkova [Khar' kov Polytechnic Institute (Ukraine)

    2007-06-15

    Today, the operational efficiency of coal-preparation shops at coke plants largely depends on the flotation process, since flotation is the basic method of regenerating the slurry water in the water-slurry systems and the basic enrichment process for small-grain coal slurries. At The Coal-Chemistry Institute, attempts have been made to address the growing demand for readily available and relatively inexpensive flotational reagents. In particular, a list of promising coke-industry byproducts for use as flotational reagents has been compiled, and the possibility of reducing their toxicity has been established. In addition, various industrial byproducts and wastes have been investigated in terms of flotational activity.

  9. Uptake of DNA by cancer cells without a transfection reagent

    Directory of Open Access Journals (Sweden)

    Yanping Kong

    Full Text Available Abstract Background Cancer cells exhibit elevated levels of glucose uptake and may obtain pre-formed, diet-derived fatty acids from the bloodstream to boost their rapid growth; they may also use nucleic acid from their microenvironment. The study of processing nucleic acid by cancer cells will help improve the understanding of the metabolism of cancer. DNA is commonly packaged into a viral or lipid particle to be transferred into cells; this process is called transfection in laboratory. Cancer cells are known for having gene mutations and the evolving ability of endocytosis. Their uptake of DNAs might be different from normal cells; they may take in DNAs directly from the environment. In this report, we studied the uptake of DNAs in cancer cells without a transfection reagent. Methods A group of DNA fragments were prepared with PCR and labeled with isotope phosphorous-32 to test their uptake by Huh 7 (liver cancer and THLE3 (normal liver cells after incubation overnight by counting radioactivity of the cells’ genomic DNA. Multiple cell lines including breast cancer and lung cancer were tested with the same method. DNA molecules were also labeled with fluorescence to test the location in the cells using a kit of “label it fluorescence in situ hybridization (FISH” from Mirus (USA. Results The data demonstrated that hepatocellular carcinoma cells possess the ability to take in large DNA fragments directly without a transfection reagent whereas normal liver cells cannot. Huh7 and MDA-MB231 cells displayed a significantly higher Rhodamine density in the cytoplasmic phagosomes and this suggests that the mechanism of uptake of large DNA by cancer cells is likely endocytosis. The efficacy of uptake is related to the DNA’s size. Some cell lines of lung cancer and breast cancer also showed similar uptake of DNA. Conclusions In the present study, we have revealed the evidence that some cancer cells, but not nontumorigenic cells, can take DNA

  10. Storage Conditions of Conjugated Reagents Can Impact Results of Immunogenicity Assays

    Directory of Open Access Journals (Sweden)

    Robert J. Kubiak

    2016-01-01

    Full Text Available Consistent performance of anti-drug antibody (ADA assays through all stages of clinical development is critical for the assessment of immunogenicity and interpretation of PK, PD, safety, and efficacy. The electrochemiluminescent assays commonly employed for ADA measurement use drug conjugated with ruthenium and biotin to bind ADA in samples. Here we report an association between high nonspecific ADA responses in certain drug-naïve individuals and the storage buffer of the conjugated reagents used in a monoclonal antibody ADA assay. Ruthenylated reagents stored in phosphate-buffered saline (PBS buffer had increased levels of aggregate and produced variable and high baseline responses in some subjects. Reagents stored in a histidine-sucrose buffer (HSB had lower aggregate levels and produced low sample responses. In contrast to PBS, conjugated reagents formulated in HSB remained low in aggregate content and in sample response variability after 5 freeze/thaw cycles. A reagent monitoring control (RMC serum was prepared for the real-time evaluation of conjugated reagent quality. Using appropriate buffers for storage of conjugated reagents together with RMCs capable of monitoring of reagent aggregation status can help ensure consistent, long-term performance of ADA methods.

  11. Lipid-based Transfection Reagents Exhibit Cryo-induced Increase in Transfection Efficiency

    Directory of Open Access Journals (Sweden)

    Helena Sork

    2016-01-01

    Full Text Available The advantages of lipid-based transfection reagents have permitted their widespread use in molecular biology and gene therapy. This study outlines the effect of cryo-manipulation of a cationic lipid-based formulation, Lipofectamine 2000, which, after being frozen and thawed, showed orders of magnitude higher plasmid delivery efficiency throughout eight different cell lines, without compromising cell viability. Increased transfection efficiency with the freeze-thawed reagent was also seen with 2'-O-methyl phosphorothioate oligonucleotide delivery and in a splice-correction assay. Most importantly, a log-scale improvement in gene delivery using the freeze-thawed reagent was seen in vivo. Using three different methods, we detected considerable differences in the polydispersity of the different nucleic acid complexes as well as observed a clear difference in their surface spreading and sedimentation, with the freeze-thawed ones displaying substantially higher rate of dispersion and deposition on the glass surface. This hitherto overlooked elevated potency of the freeze-thawed reagent facilitates the targeting of hard-to-transfect cells, accomplishes higher transfection rates, and decreases the overall amount of reagent needed for delivery. Additionally, as we also saw a slight increase in plasmid delivery using other freeze-thawed transfection reagents, we postulate that freeze-thawing might prove to be useful for an even wider variety of transfection reagents.

  12. On extraction reagents for hydrometallurgy

    International Nuclear Information System (INIS)

    Zolotov, Yu.A.

    1975-01-01

    Fundamental requirements to the extractants are considered. Ways of obtaining selective extractants are discussed in particular on the basis of coordination chemistry achivements. Attention is drawn to expediency of study (as extractants) of flotation reagents, additions to the oil, pesticides, accelerators of caoutchouc vulcanization

  13. Genotoxicity assessment of membrane concentrates of landfill leachate treated with Fenton reagent and UV-Fenton reagent using human hepatoma cell line.

    Science.gov (United States)

    Wang, Guifang; Lu, Gang; Yin, Pinghe; Zhao, Ling; Yu, Qiming Jimmy

    2016-04-15

    Membrane concentrates of landfill leachates contain organic and inorganic contaminants that could be highly toxic and carcinogenic. In this paper, the genotoxicity of membrane concentrates before and after Fenton and UV-Fenton reagent was assessed. The cytotoxicity and genotoxicity was determined by using the methods of methyltetrazolium (MTT), cytokinesis-block micronucleus (CBMN) and comet assay in human hepatoma cells. MTT assay showed a cytotoxicity of 75% after 24h of exposure to the highest tested concentration of untreated concentrates, and no cytotoxocity for UV-Fenton and Fenton treated concentrates. Both CBMN and comet assays showed increased levels of genotoxicity in cells exposed to untreated concentrates, compared to those occurred in cells exposed to UV-Fenton and Fenton reagent treated concentrates. There was no significant difference between negative control and UV-Fenton treated concentrates for micronucleus and comet assay parameters. UV-Fenton and Fenton treatment, especially the former, were effective methods for degradation of bisphenol A and nonylphenol in concentrates. These findings showed UV-Fenton and Fenton reaction were effective methods for treatment of such complex concentrates, UV-Fenton reagent provided toxicological safety of the treated effluent, and the genotoxicity assays were found to be feasible tools for assessment of toxicity risks of complex concentrates. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Rapid heteroatom transfer to arylmetals utilizing multifunctional reagent scaffolds

    Science.gov (United States)

    Gao, Hongyin; Zhou, Zhe; Kwon, Doo-Hyun; Coombs, James; Jones, Steven; Behnke, Nicole Erin; Ess, Daniel H.; Kürti, László

    2017-07-01

    Arylmetals are highly valuable carbon nucleophiles that are readily and inexpensively prepared from aryl halides or arenes and widely used on both laboratory and industrial scales to react directly with a wide range of electrophiles. Although C-C bond formation has been a staple of organic synthesis, the direct transfer of primary amino (-NH2) and hydroxyl (-OH) groups to arylmetals in a scalable and environmentally friendly fashion remains a formidable synthetic challenge because of the absence of suitable heteroatom-transfer reagents. Here, we demonstrate the use of bench-stable N-H and N-alkyl oxaziridines derived from readily available terpenoid scaffolds as efficient multifunctional reagents for the direct primary amination and hydroxylation of structurally diverse aryl- and heteroarylmetals. This practical and scalable method provides one-step synthetic access to primary anilines and phenols at low temperature and avoids the use of transition-metal catalysts, ligands and additives, nitrogen-protecting groups, excess reagents and harsh workup conditions.

  15. The establishment of a WHO Reference Reagent for anti-malaria (Plasmodium falciparum) human serum.

    Science.gov (United States)

    Bryan, Donna; Silva, Nilupa; Rigsby, Peter; Dougall, Thomas; Corran, Patrick; Bowyer, Paul W; Ho, Mei Mei

    2017-08-05

    At a World Health Organization (WHO) sponsored meeting it was concluded that there is an urgent need for a reference preparation that contains antibodies against malaria antigens in order to support serology studies and vaccine development. It was proposed that this reference would take the form of a lyophilized serum or plasma pool from a malaria-endemic area. In response, an immunoassay standard, comprising defibrinated human plasma has been prepared and evaluated in a collaborative study. A pool of human plasma from a malaria endemic region was collected from 140 single plasma donations selected for reactivity to Plasmodium falciparum apical membrane antigen-1 (AMA-1) and merozoite surface proteins (MSP-1 19 , MSP-1 42 , MSP-2 and MSP-3). This pool was defibrinated, filled and freeze dried into a single batch of ampoules to yield a stable source of naturally occurring antibodies to P. falciparum. The preparation was evaluated by an enzyme-linked immunosorbent assay (ELISA) in a collaborative study with sixteen participants from twelve different countries. This anti-malaria human serum preparation (NIBSC Code: 10/198) was adopted by the WHO Expert Committee on Biological Standardization (ECBS) in October 2014, as the first WHO reference reagent for anti-malaria (Plasmodium falciparum) human serum with an assigned arbitrary unitage of 100 units (U) per ampoule. Analysis of the reference reagent in a collaborative study has demonstrated the benefit of this preparation for the reduction in inter- and intra-laboratory variability in ELISA. Whilst locally sourced pools are regularly use for harmonization both within and between a few laboratories, the presence of a WHO-endorsed reference reagent should enable optimal harmonization of malaria serological assays either by direct use of the reference reagent or calibration of local standards against this WHO reference. The intended uses of this reference reagent, a multivalent preparation, are (1) to allow cross

  16. Effect of reagent charge on the labeling of erythrocyte membrane proteins by photoactivated reagents

    International Nuclear Information System (INIS)

    Schaeffer, J.C.; Hakimian, R.; Shimer, M.L.

    1986-01-01

    Leaky erythrocyte ghosts were labeled with 3 H-[2-(4-azido-2-nitroanilino)ethyl]trimethylammonium iodide (cationic label) or 3 H-N-(4-azido-2-nitrophenyl)-β-alanine (anionic label). After the membranes were thoroughly washed, seven times as much cationic label was associated with the membranes as anionic label at 5 μM, whereas at 50 μM the cationic label was favored 15-fold. The distribution of label in the membrane proteins was ascertain by SDS-gel electrophoresis followed by autoradiography. At 50 μM cationic label, erythrocyte membrane protein bands 1,2,3,4.2, and 5 were intensely labeled, while band 6 was labeled weakly. At 5 μM cationic label, bands 1 and 4.2 were heavily labeled, while 2,3 and 5 were labeled less well. At both 50 μM and 5 μM anionic label, bands 1 and 6 were most prominently labeled. Bands 2,3,4.2 and 5 were labeled also at 50 μM, but they were labeled only very weakly at 5 μM. Band 4.1 was labeled very poorly if at all by either reagent. A mixture of the reagents gave an additive pattern. Thus, the charge and concentration of these reagents appear to play a major role in their ability to label membrane proteins indiscriminately. Because these reagents contain the same chromophore, 4-azido-2-nitroaniline, and differ mainly only in their charge, they may prove useful in assessing the location of charged sites on proteins in supramolecular complexes

  17. Optimal lipofection reagent varies with the molecular modifications of the DNA.

    Science.gov (United States)

    Conrad, A H; Behlke, M A; Jaffredo, T; Conrad, G W

    1998-10-01

    Cationic lipid reagents differ in their cytofection efficacy with different cell types. No evidence has addressed whether the same lipid reagent is best for different DNAs in a single cell line. Immortalized avian embryonic cardiomyocytes cultured in vitro were tested with 15 cationic lipid reagents using (A) a beta-gal expression plasmid, (B) a fluorescein-tagged, phosphorothioate-modified ODN B, (C) a fluorescein-tagged, ethoxy-modified ODN C with the same nucleotide sequence as ODN B, and (D) a fluorescein-tagged, phosphorothioate-modified ODN D with a different nucleotide sequence from ODNs B and C. Cytofection was scored as percent of cells expressing beta-gal activity or showing diffuse cellular fluorescence. The best lipid reagents for the phosphorothioate-modified ODNs were ODN-specific and markedly different from the best lipid reagents for the expression plasmid or for the ethoxy-modified ODN. These results suggest that the best cationic lipid reagent for a particular cell type varies with the physical and chemical form of the DNA being transfected into the cells.

  18. The prothrombin time/international normalised ratio (PT/INR) line: derivation of local INR with commercial thromboplastins and coagulometers – two independent studies

    DEFF Research Database (Denmark)

    Poller, Leon; Ibrahim, S.; Keown, M.

    2011-01-01

    reagents, and from 7.0% to 2.6% with rabbit reagents. In the second study, deviation was reduced from 11.2% to 0.4% with human reagents by both local ISI calibration and the PT/INR Line. With rabbit reagents, 10.4% deviation was reduced to 1.1% with both procedures; 4.9% deviation was reduced to 0.5......Background: The WHO scheme for prothrombin time (PT) standardization has been limited in application, because of its difficulties in implementation, particularly the need for mandatory manual PT testing and for local provision of thromboplastin international reference preparations (IRP). Methods...... thromboplastins and coagulometers. INRs were compared with manual certified values with thromboplastin IRP from expert centres and in the second study also with INRs from local ISI calibrations. Results: In the first study with the PT/INR Line, 8.7% deviation from certified INRs was reduced to 1.1% with human...

  19. Hydrothermal Preparation and Characterization of Ultralong Strontium-Substituted Hydroxyapatite Whiskers Using Acetamide as Homogeneous Precipitation Reagent

    Science.gov (United States)

    Xu, Jianqiang; Yang, Yaoqi; Wan, Rong; Zhang, Weibin

    2014-01-01

    The ultralong strontium- (Sr-) substituted hydroxyapatite (SrHAp) whiskers were successfully prepared using acetamide as homogeneous precipitation reagent. The effect of the Sr substitution amount on the lattice constants and proliferation of human osteoblast cells (MG-63) was further investigated. The results showed that the SrHAp whiskers with diameter of 0.2–12 μm and ultralong length up to 200 μm were obtained and the Sr substitution level could be facilely tailored by regulating the initial molar ratio of Sr/(Sr + Ca) in raw materials. The Sr2+ replaced part of Ca2+ and the lattice constants increased apparently with the increase of the Sr substitution amount. Compared with the pure HAp whiskers, the Sr substitution apparently stimulated the proliferation of MG-63 at certain extracted concentrations. Our study suggested that the obtained SrHAp whiskers might be used as bioactive and mechanical reinforcement materials for hard tissue regeneration applications. PMID:24592192

  20. Sample preparation in alkaline media

    International Nuclear Information System (INIS)

    Nobrega, Joaquim A.; Santos, Mirian C.; Sousa, Rafael A. de; Cadore, Solange; Barnes, Ramon M.; Tatro, Mark

    2006-01-01

    The use of tetramethylammonium hydroxide, tertiary amines and strongly alkaline reagents for sample treatment involving extraction and digestion procedures is discussed in this review. The preparation of slurries is also discussed. Based on literature data, alkaline media offer a good alternative for sample preparation involving an appreciable group of analytes in different types of samples. These reagents are also successfully employed in tailored speciation procedures wherein there is a critical dependence on maintenance of chemical forms. The effects of these reagents on measurements performed using spectroanalytical techniques are discussed. Several undesirable effects on transport and atomization processes necessitate use of the method of standard additions to obtain accurate results. It is also evident that alkaline media can improve the performance of techniques such as inductively coupled plasma mass spectrometry and accessories, such as autosamplers coupled to graphite furnace atomic absorption spectrometers

  1. Rapid and Sensitive Determination of Lipid Oxidation Using the Reagent Kit Based on Spectrophotometry (FOODLABfat System

    Directory of Open Access Journals (Sweden)

    Chang Woo Kwon

    2016-01-01

    Full Text Available The reliability and availability of FOODLABfat system for determining acid value (AV and peroxide value (POV were assessed during the hydrolytic rancidification and lipid oxidation of edible oils. This reagent kit based on spectrophotometry was compared to the official methods (ISO 660 and 3960 protocols based on manual titration employing the standard mixture for the simulated oxidation models and edible oils during the thermally induced oxidation at 180°C. The linear regression line of standard mixture and the significant difference of thermally oxidized time course study determined between them showed high correlations (R2=0.998 and p<0.05 in both AVs and POVs. Considering ISO protocols with a probability of human error in manual titration, the rapidness and simplicity of the reagent kit based on spectrophotometry make it a promising alternative to monitor the lipid oxidation of edible oils and lipid-containing foods.

  2. Synthesis of netlike gold nanoparticles using ampicillin as a stabilizing reagent and its application

    International Nuclear Information System (INIS)

    Song, Y.Z.; Zhou, J.F.; Song, Y.; Cheng, Z.P.; Xu, J.

    2012-01-01

    Graphical abstract: Electrochemical deposition of netlike gold nanoparticles (GNPs) on the surface of glassy carbon electrode and preparation of netlike GNPs in aqueous solution using ampicillin as a stabilizing reagent were proposed. The catalytic properties of netlike gold nanoparticles on the glassy carbon electrode for dopamine were demonstrated. The results indicate that the netlike gold nanoparticle modified electrode has an excellent repeatability and reproducibility. Display Omitted Highlights: ► Synthesis of netlike gold nanoparticles using ampicillin as a stabilizing reagent. ► Excellent repeatability and reproducibility of netlike gold nanoparticle modified glassy carbon electrode. ► The catalytic properties of netlike gold nanoparticle for dopamine. -- Abstract: Electrochemical deposition of netlike gold nanoparticles on the surface of glassy carbon electrode and preparation of netlike GNPs in aqueous solution using ampicillin as a stabilizing reagent were proposed. The netlike gold nanoparticles were characterized by scanning electron microscope, transmission electron microscope, infrared spectrometer, UV spectrophotometer, powder X-ray diffractometer and electrochemical analyzer. The catalysis of the netlike gold nanoparticles on the glassy carbon electrode for dopamine was demonstrated. The results indicate that the gold nanoparticle modified electrode has an excellent repeatability and reproducibility.

  3. Inactivation and stability of viral diagnostic reagents treated by gamma radiation

    International Nuclear Information System (INIS)

    White, L.A.; Freeman, C.Y.; Hall, H.E.; Forrester, B.D.

    1990-01-01

    The objective of this study was to apply the pertinent findings from gamma inactivation of virus infectivity to the production of high quality diagnostic reagents. A Gammacell 220 was used to subject 38 viruses grown in either susceptible tissue cultures or embryonated chicken eggs to various doses of gamma radiation from a cobalt-60 source. The radiation required to reduce viral infectivity was 0.42 to 3.7 megarads (Mrad). The effect of gamma treatment on the antigenic reactivity of reagents for the complement fixation (CF), hemagglutination (HA) and neuraminadase assays was determined. Influenza antigens inactivated with 1.7 Mrad displayed comparable potency, sensitivity, specificity and stability to those inactivated by standard procedures with beta-propiolactone (BPL). Significant inactivation of influenza N1 and B neuraminidase occurred with >2.4 Mrad radiation at temperatures above 4 0 C. All 38 viruses were inactivated, and CF or HA antigens were prepared successfully. Antigenic potency remained stable with all antigens for 3 years and with 83% after 5 years storage. Influenza HA antigens evaluated after 9 years of storage demonstrated 86% stability. Gamma radiation is safer than chemical inactivation procedures and is a reliable and effective replacement for BPL in preparing diagnostic reagents. (author)

  4. Inactivation and stability of viral diagnostic reagents treated by gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    White, L A; Freeman, C Y; Hall, H E; Forrester, B D [Department of Health and Human Services, Atlanta, GA (USA)

    1990-10-01

    The objective of this study was to apply the pertinent findings from gamma inactivation of virus infectivity to the production of high quality diagnostic reagents. A Gammacell 220 was used to subject 38 viruses grown in either susceptible tissue cultures or embryonated chicken eggs to various doses of gamma radiation from a cobalt-60 source. The radiation required to reduce viral infectivity was 0.42 to 3.7 megarads (Mrad). The effect of gamma treatment on the antigenic reactivity of reagents for the complement fixation (CF), hemagglutination (HA) and neuraminadase assays was determined. Influenza antigens inactivated with 1.7 Mrad displayed comparable potency, sensitivity, specificity and stability to those inactivated by standard procedures with beta-propiolactone (BPL). Significant inactivation of influenza N1 and B neuraminidase occurred with >2.4 Mrad radiation at temperatures above 4{sup 0}C. All 38 viruses were inactivated, and CF or HA antigens were prepared successfully. Antigenic potency remained stable with all antigens for 3 years and with 83% after 5 years storage. Influenza HA antigens evaluated after 9 years of storage demonstrated 86% stability. Gamma radiation is safer than chemical inactivation procedures and is a reliable and effective replacement for BPL in preparing diagnostic reagents. (author).

  5. Concentration determination of methyl magnesium chloride and other Grignard reagents by potentiometric titration with in-line characterization of reaction species by FTIR spectroscopy.

    Science.gov (United States)

    Chen, Yadan; Wang, Tao; Helmy, Roy; Zhou, George X; LoBrutto, Rosario

    2002-07-01

    A potentiometric titration method for methyl magnesium chloride and other Grignard reagents based on the reaction with 2-butanol in THF has been developed and validated. The method employs a commercially available platinum electrode, using an electrolyte compatible with non-aqueous solvents. Well-defined titration curves were obtained, along with excellent method precision. The endpoint was precisely determined based on the first derivative of the titration curve. Different solvents such as THF, diethyl ether and methylene chloride provided similar results with regard to sharpness of the endpoint and method precision. The method was applied to a wide array of Grignard reagents including methyl magnesium bromide, ethyl magnesium chloride, propyl magnesium chloride, vinyl magnesium chloride, phenyl magnesium chloride, and benzyl magnesium chloride with similar precision and accuracy. Application of in-line FTIR was demonstrated for in situ monitoring of the titration reaction, allowing characterization of the reaction species. An authentic spectrum of the MeMgCl-THF complex was obtained using spectral subtraction and the vibrational absorbance bands were identified. FTIR also provided an alternative for detecting the titration endpoint, and the titration results so obtained, provided a cross-validation of the accuracy of the potentiometric titration.

  6. STUDY ON OIL WASTEWATER TREATMENT WITH POLYMERIC REAGENTS

    Directory of Open Access Journals (Sweden)

    RODICA BUCUROIU

    2016-04-01

    Full Text Available Used the polymeric reagents in oil wastewater treatment is an effective method of eliminate hydrocarbons. The present study aims to finding reagents that lead to lowering of extractible (EXT, suspended solids (SS and chemical oxygen demand (COD of industrial wastewater from washing cars in loading ramps petroleum products. For this purpose five reagents were tested, namely: polyamines, cationic polyacrylamides, polydiallydimethyl ammonium chloride (PolyDADMAC, melamine formaldehyde polymer resin and polydicyandiamide polymer resin. Obtaining removal degrees over 80 % justifies using this method in the industrial practice.

  7. Polymer-supported reagents with enhanced metal ion recognition: Application to separations science

    International Nuclear Information System (INIS)

    Alexandratos, S.D.

    1993-01-01

    The design and development of polymer-supported reagents with ever-increasing specificities for targeted metal ions remains an important areas of research. The need for efficient separation schemes for both ions and molecules has been outlined in a report by the National Research Council (King) and will gain increased emphasis as environmental restoration is pursued. Polymer-supported reagents are unique in their ability to be applied in an environmentally benign manner to a host of challenges. Such reagents, in the form of beads, can be applied to continuous separation processes ranging from the removal of metal ions in water to the recovery of medicinal drugs produced through biotechnological means. The application of polymer-supported reagents to metal ion separations still requires developing a fundamental understanding of ligand-metal interactions, the role of the polymer in those interactions, and the methods of synthesizing such polymeric reagents in a readily applicable form. Ion exchange resins with sulfonic acid ligands are the prototypical polymer-supported reagents, and their properties have been exhaustively studied (Helfferich). The high acidity of the sulfonic acid group, however, precludes much selectivity, and it displays a very limited range of reaction free energy values with different metal ions (Boyd et al.). The carboxylic acid ligand, present in the acrylate resins, is more selective, though its weak acidity requires relatively high pH solutions for it to be effective. Research has thus been focused on the preparation of polymer-supported reagents with high levels of specificity for targeted metal ions

  8. Reagents for radioimmunological determination of carcinoembryonic antigen (CEA)

    International Nuclear Information System (INIS)

    Albert, Z.; Balbierz, H.; Breberowicz, J.

    1978-01-01

    The work was undertaken to prepare the reagents for carcinoembryonic antigen (CEA) radioimmunoassay with double antibody method. The CEA standard of high immunoreactivity was prepared and purified. The purified CEA was used for immunozation of goats. The goat anti - CEA sera were received. IgG fraction from normal goat serum was purified and used for the production of horse anti-goat IgG serum which was then used in the radioimmunoassay of CEA. The labelling of CEA with iodine-125 has been carried out be means of the enzymatic method.(Z.R.)

  9. Standardization of human thyrotropin radioimmunoassay and its application to the purification of this hormone to the preparation of the assay reagents

    International Nuclear Information System (INIS)

    Lin, L.H.

    1991-01-01

    The various steps that are necessary for setting up the thyrotropin radioimmunoassay are presented below. Radioiodination was carried out through the Chloramine T method and the labeled purification performed on Sephadex G-100. Purification of human thyrotropin from side fractions obtained during the purification of growth hormone was carried out in order to obtain a pure reagent for use in the radioimmunoassay. The employment of the hormone obtained was evaluated as the radioimmunoassay tracer in comparison with that prepared from the hormone received from the NIDDKD, U.S.A. The results indicated that although it was not possible to obtain a hormone with a purity degree adequate to be used as the tracer, enough experience was acquired for the isolation of thyrotropin. (author)

  10. Influence of the apparent molecular size of humic substances on the efficiency of coagulation using Fenton's reagent

    Directory of Open Access Journals (Sweden)

    MARCELO DE JULIO

    2013-06-01

    Full Text Available This work used Fenton's reagent as a coagulating agent in the treatment of water samples with high true colour caused by humic substances (HS extracted from peat. In addition, the effects of the apparent molecular size of HS on coagulation, flocculation and flotation were studied. To that end, four distinct water samples having the same true colour were prepared using HS with different molecular sizes, which were obtained by ultrafiltration fractioning. Through optimisation of coagulant dosage and coagulation pH, as well as posterior construction of coagulation diagrams for each water sample, it was verified that the sample prepared with the smallest apparent molecular size of HS was the most difficult to treat, requiring higher coagulant (Fenton's reagent dosages than samples prepared with larger HS molecular sizes. Furthermore, filtration experiments after dissolved air flotation (DAF were carried out in an attempt to simulate conventional treatment. The most representative results in filtered water were: apparent colour ≤ 3 HU; turbidity Este trabalho empregou o reagente de Fenton como agente coagulante no tratamento de águas contendo cor elevada causada pela introdução de substâncias húmicas extraídas de turfa. Além disto, foi estudado o efeito do tamanho molecular aparente das substâncias húmicas na eficiência da coagulação, floculação e flotação de águas; para isto foram preparadas quatro águas distintas apresentado a mesma cor verdadeira, mas com substâncias húmicas de diferentes tamanhos moleculares, obtidas por fracionamento por ultrafiltração. Por meio da otimização da dosagem de coagulante e respectivo pH de coagulação e posterior construção dos diagramas de coagulação para cada água de estudo, verificou-se que a água preparada com as substâncias húmicas de menor tamanho molecular aparente apresentou maior grau de dificuldade para tratamento, requerendo dosagens de coagulante (reagente de Fenton bem

  11. HASE - The Helsinki adaptive sample preparation line

    Energy Technology Data Exchange (ETDEWEB)

    Palonen, V., E-mail: vesa.palonen@helsinki.fi [Department of Physics, University of Helsinki, P.O. Box 43, FI-00014 (Finland); Pesonen, A. [Laboratory of Chronology, Finnish Museum of Natural History, P.O. Box 64, FI-00014 (Finland); Herranen, T.; Tikkanen, P. [Department of Physics, University of Helsinki, P.O. Box 43, FI-00014 (Finland); Oinonen, M. [Laboratory of Chronology, Finnish Museum of Natural History, P.O. Box 64, FI-00014 (Finland)

    2013-01-15

    We have designed and built an adaptive sample preparation line with separate modules for combustion, molecular sieve handling, CO{sub 2} gas cleaning, CO{sub 2} storage, and graphitization. The line is also connected to an elemental analyzer. Operation of the vacuum equipment, a flow controller, pressure sensors, ovens, and graphitization reactors are automated with a reliable NI-cRIO real-time system. Stepped combustion can be performed in two ovens at temperatures up to 900 Degree-Sign C. Depending on the application, CuO or O{sub 2}-flow combustion can be used. A flow controller is used to adjust the O{sub 2} flow and pressure during combustion. For environmental samples, a module for molecular sieve regeneration and sample desorption is attached to the line replacing the combustion module. In the storage module, CO{sub 2} samples can be stored behind a gas-tight diaphragm valve and either stored for later graphitization or taken for measurements with separate equipment (AMS gas ion source or a separate mass spectrometer). The graphitization module consists of four automated reactors, capable of graphitizing samples with masses from 3 mg down to 50 {mu}g.

  12. Handling Pyrophoric Reagents

    Energy Technology Data Exchange (ETDEWEB)

    Alnajjar, Mikhail S.; Haynie, Todd O.

    2009-08-14

    Pyrophoric reagents are extremely hazardous. Special handling techniques are required to prevent contact with air and the resulting fire. This document provides several methods for working with pyrophoric reagents outside of an inert atmosphere.

  13. The adsorption of chelating reagents on oxide minerals

    International Nuclear Information System (INIS)

    Bryson, M.A.W.

    1984-06-01

    This work constitutes a fundamental study of the interaction between chelating reagents and oxide minerals. The adsorption mechanisms have been elucidated for most of the systems generated by the oxides of copper(II) or iron(III) and chelating reagents octyl hydroxamate, N-phenylbenzohydroxamate, salicylaldoxime, 5-nitro-salicylaldoxime or 8-hydroxyquinoline. In order to better understand the adsorption process associated with copper(II) oxide, the oxide was recrystallized to produce a coarser material with a more uniform surface. This allowed the oxide surface to be viewed under the scanning electron microscope. A detailed investigation of the effect of the system variables; pH, conditioning period, concentration, temperature, surface area and dispersing reagent on the rate of precipitation of the copper chelate species of general form, Cu(chel) 2 , was made. In addition the chemical nature of the adsorbed species and the structural form of the precipitates were determined with the aid of infra-red spectroscopy and the scanning electron microscope. On the basis of these results a model has been formulated for the adsorption processes. The precipitation process was examined in more detail by the study of the adsorption of chelate on copper metal. Contact angle measurements of air bubbles on copper metal conditioned with chelate were related to the adsorption results in an attempt to isolate the optimum conditions for flotation of oxide minerals

  14. Reagent-Free Quantification of Aqueous Free Chlorine via Electrical Readout of Colorimetrically Functionalized Pencil Lines.

    Science.gov (United States)

    Mohtasebi, Amirmasoud; Broomfield, Andrew D; Chowdhury, Tanzina; Selvaganapathy, P Ravi; Kruse, Peter

    2017-06-21

    Colorimetric methods are commonly used to quantify free chlorine in drinking water. However, these methods are not suitable for reagent-free, continuous, and autonomous applications. Here, we demonstrate how functionalization of a pencil-drawn film with phenyl-capped aniline tetramer (PCAT) can be used for quantitative electric readout of free chlorine concentrations. The functionalized film can be implemented in a simple fluidic device for continuous sensing of aqueous free chlorine concentrations. The sensor is selective to free chlorine and can undergo a reagent-free reset for further measurements. Our sensor is superior to electrochemical methods in that it does not require a reference electrode. It is capable of quantification of free chlorine in the range of 0.1-12 ppm with higher precision than colorimetric (absorptivity) methods. The interactions of PCAT with the pencil-drawn film upon exposure to hypochlorite were characterized spectroscopically. A previously reported detection mechanism relied on the measurement of a baseline shift to quantify free chlorine concentrations. The new method demonstrated here measures initial spike size upon exposure to free chlorine. It relies on a fast charge built up on the sensor film due to intermittent PCAT salt formation. It has the advantage of being significantly faster than the measurement of baseline shift, but it cannot be used to detect gradual changes in free chlorine concentration without the use of frequent reset pulses. The stability of PCAT was examined in the presence of free chlorine as a function of pH. While most ions commonly present in drinking water do not interfere with the free chlorine detection, other oxidants may contribute to the signal. Our sensor is easy to fabricate and robust, operates reagent-free, and has very low power requirements and is thus suitable for remote deployment.

  15. Fast biosensor with reagent layer

    NARCIS (Netherlands)

    2008-01-01

    A detection system and a sensor chip for detecting target mols., and thus corresponding analytes in a sample is described. Typically the detection system includes a sensor chip. The sensor chip (1) comprises on its detection surface a dissolvable reagent layer. When the dissolvable reagent layer is

  16. [A stable reagent for the-single stage determination of inorganic phosphate].

    Science.gov (United States)

    Pupyshev, A B

    1991-01-01

    A recipe of a simple reagent for phosphorus detection has been developed, consisting of ammonium molybdate (4 mM), sulfuric acid (0.2 N), and Tween-80 (0.2%). The developing phosphate staining may be registered in 15 min at a wavelength of 350 nm. The product molar extinction is equal to 1.20.10(4) M-1.cm-1, this being close to that of molybdic blue. Phosphate staining is characterized by the stability of results and insensitivity to the presence of a number of substances used in enzymology. The prepared reagent is fit for experiments within a fortnight if stored in the cold.

  17. Blister pouches for effective reagent storage and release for low-cost point-of-care diagnostic applications

    CSIR Research Space (South Africa)

    Smith, S

    2016-02-01

    Full Text Available Lab-on-a-chip devices are often applied to point-of-care diagnostic solutions as they are low-cost, compact, disposable, and require only small sample volumes. For such devices, various reagents are required for sample preparation and analysis and...

  18. Expression of blood group I and i active carbohydrate sequences on cultured human and animal cell lines assessed by radioimmunoassays with monoclonal cold agglutinins

    International Nuclear Information System (INIS)

    Childs, R.A.; Kapadia, A.; Feizi, T.

    1980-01-01

    Human monoclonal anti-I and anti-i, reactive with known carbohydrate sequences, have been used as reagents to quantitate (by radioimmunoassay) and visualize (by immunofluorescence) the expression of the various blood group I and i antigenic determinants in a variety of cultured cell lines commonly used in laboratory investigations. It has been shown that the antigens they recognize are widely distributed on the surface of human and animal cell lines, expressed in varying amounts in different cell lines and on individual cells within a given cell line. In two cell lines, a transformation-associated increase in the expression of I antigen was observed. Because of their precise specificity for defined carbohydrate chain domains, these autoantibodies have become valuable reagents in biological chemistry. (orig.) [de

  19. Production of reagents for cleaning fluids

    Energy Technology Data Exchange (ETDEWEB)

    Grunberg, I V; Korostyleva, R N; Pytel, S P; Spasskii, P I; Titarenko, N K; Trachtenberg, S I; Yushkevich, V I

    1980-10-25

    A method for producing reagents for cleaning fluids is proposed using polymerization of acrylonitril, metachrylate or a mixture of the two in water and saponification of the polymers with alakali. To reduce the consumption of monomers and increase the quality of the reagents, 0.4-1.0 parts humic substances, 0.2-1.0 parts hydrolizate from tanning waste products and 1.2-4.0 parts monomers are added to the reaction medium, followed by copolymerization in an acid medium. The proposed method ensures quality reagents which combine lower water yield with a moderate increase in viscosity when acting on clay solutions. Compared with the current method, this method lowers the consumption of an expensive and hard-to-find monomer 1.2-1.4X for one ton of reagent, which lowers the cost of raw material by 1.3-1.7X. This results in a savings of 195-385 rubles per ton of reagent, 600-1200 thousand at 3000 tons/yr.

  20. 21 CFR 660.25 - Potency tests without reference preparations.

    Science.gov (United States)

    2010-04-01

    ... recommended for slide tests or microplate techniques. Blood Grouping Reagent recommended for slide test... Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood Grouping Reagents are not available shall be tested for potency by a method approved by the Director...

  1. Radiation chemical technology of industrial polymer reagents development

    International Nuclear Information System (INIS)

    Kudaibergenov, S.; Nurkeeva, Z.; Mun, G.; Sigitov, V.; Maltzeva, R.; Petukhov, V.; Tchekushin, A.

    1996-01-01

    The goal of this project is to develop the technology of producing of polymeric reagents from the raw materials of Kazakstan for application in medicine, agriculture, enhanced oil recovery and ecology. To achieve the objectives the next technological lines or operations (Blocks) should be realized: 1. Rectification column and distilling apparatus for purification of monomers and solvents including analytical equipment to control the quality of the final product; 2. Irradiation of reaction mixture by either gamma-irradiation source Co-60; 3. Purification of polymer reagents; 4. Producing of commercial products. It is supposed that the power irradiation devices for producing of hydrogels will be mounted on the research atomic reactor of the Almaty Branch of the Institute of Atomic Energy of the National Nuclear Center. There are high qualification personal which has much experience in radioactive materials operating. Irradiation technologies will provide the low cost of hydrogels, approximately 250-300 US$ per 1 ton. Expected results. One can expect that the realization of this project allows to produce hydrogels in industrial scale to cover partly the requirements of medicine, agriculture, oil industry and ecology

  2. Small particle reagent based on crystal violet dye for developing latent fingerprints on non-porous wet surfaces

    Directory of Open Access Journals (Sweden)

    Richa Rohatgi

    2015-12-01

    Full Text Available Small particle reagent (SPR is a widely used method for developing latent fingerprints on non-porous wet surfaces. SPR based on zinc carbonate hydroxide monohydrate, ZnCo3·2Zn(OH2·H2O – also called basic zinc carbonate – has been formulated. The other ingredients of the formulation are crystal violet dye and a commercial liquid detergent. The composition develops clear, sharp and detailed fingerprints on non-porous items, after these were immersed separately in clean and dirty water for variable periods of time. The ability of the present formulation to detect weak and faint chance prints not only enhances its utility, but also its potentiality in forensic case work investigations. The raw materials used to prepare the SPR are cost-effective and non-hazardous.

  3. A convenient method to synthesize N-[3H]methyl-N-nitrosocarbamate transfer reagents

    International Nuclear Information System (INIS)

    Mehta, P.; Gold, B.; Konakahara, T.

    1992-01-01

    Activated N-alkyl-N-nitrosocarbamates are useful acyl transfer reagents that are employed in the synthesis of N-alkyl-N-nitrosoureas and related N-nitroso compounds. The nitrosourea products are of chemical and biological interest because they provide access to the in situ generation of highly reactive carbonium type intermediates, which, depending on their structure, can be powerful carcinogens or antineoplastic agents. The availability of radiolabeled nitrosoureas greatly facilitates studies on their chemical and biological activities. Generally, the synthesis of activated nitrosocarbamates requires condensation of radiolabeled alkylisocyanates with the appropriate alcohol. Because radiolabeled alkylisocyanates are not commercially available and/or troublesome to synthesize, we have developed an easy and economical method for preparing N-[ 3 H]methyl-N-nitrosocarbamates suitable for use as transfer reagents utilizing 1,2,2,2-tetrachloroethyl chloroformate and [ 3 H]methylamine hydrochloride as starting materials. (author)

  4. Improved multiple displacement amplification (iMDA) and ultraclean reagents.

    Science.gov (United States)

    Motley, S Timothy; Picuri, John M; Crowder, Chris D; Minich, Jeremiah J; Hofstadler, Steven A; Eshoo, Mark W

    2014-06-06

    Next-generation sequencing sample preparation requires nanogram to microgram quantities of DNA; however, many relevant samples are comprised of only a few cells. Genomic analysis of these samples requires a whole genome amplification method that is unbiased and free of exogenous DNA contamination. To address these challenges we have developed protocols for the production of DNA-free consumables including reagents and have improved upon multiple displacement amplification (iMDA). A specialized ethylene oxide treatment was developed that renders free DNA and DNA present within Gram positive bacterial cells undetectable by qPCR. To reduce DNA contamination in amplification reagents, a combination of ion exchange chromatography, filtration, and lot testing protocols were developed. Our multiple displacement amplification protocol employs a second strand-displacing DNA polymerase, improved buffers, improved reaction conditions and DNA free reagents. The iMDA protocol, when used in combination with DNA-free laboratory consumables and reagents, significantly improved efficiency and accuracy of amplification and sequencing of specimens with moderate to low levels of DNA. The sensitivity and specificity of sequencing of amplified DNA prepared using iMDA was compared to that of DNA obtained with two commercial whole genome amplification kits using 10 fg (~1-2 bacterial cells worth) of bacterial genomic DNA as a template. Analysis showed >99% of the iMDA reads mapped to the template organism whereas only 0.02% of the reads from the commercial kits mapped to the template. To assess the ability of iMDA to achieve balanced genomic coverage, a non-stochastic amount of bacterial genomic DNA (1 pg) was amplified and sequenced, and data obtained were compared to sequencing data obtained directly from genomic DNA. The iMDA DNA and genomic DNA sequencing had comparable coverage 99.98% of the reference genome at ≥1X coverage and 99.9% at ≥5X coverage while maintaining both balance

  5. 21 CFR 866.3500 - Rickettsia serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rickettsia serological reagents. 866.3500 Section... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3500 Rickettsia serological reagents. (a) Identification. Rickettsia serological reagents are devices that consist of antigens...

  6. 21 CFR 866.3405 - Poliovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Poliovirus serological reagents. 866.3405 Section... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3405 Poliovirus serological reagents. (a) Identification. Poliovirus serological reagents are devices that consist of antigens...

  7. The application of a monolithic triphenylphosphine reagent for conducting Appel reactions in flow microreactors.

    Science.gov (United States)

    Roper, Kimberley A; Lange, Heiko; Polyzos, Anastasios; Berry, Malcolm B; Baxendale, Ian R; Ley, Steven V

    2011-01-01

    Herein we describe the application of a monolithic triphenylphosphine reagent to the Appel reaction in flow-chemistry processing, to generate various brominated products with high purity and in excellent yields, and with no requirement for further off-line purification.

  8. Reagent-loaded plastic microfluidic chips for detecting homocysteine

    International Nuclear Information System (INIS)

    Suk, Ji Won; Jang, Jae-Young; Cho, Jun-Hyeong

    2008-01-01

    This report describes the preliminary study on plastic microfluidic chips with pre-loaded reagents for detecting homocysteine (Hcy). All reagents needed in an Hcy immunoassay were included in a microfluidic chip to remove tedious assay steps. A simple and cost-effective bonding method was developed to realize reagent-loaded microfluidic chips. This technique uses an intermediate layer between two plastic substrates by selectively patterning polydimethylsiloxane (PDMS) on the embossed surface of microchannels and fixing the substrates under pressure. Using this bonding method, the competitive immunoassay for SAH, a converted form of Hcy, was performed without any damage to reagents in chips, and the results showed that the fluorescent signal from antibody antigen binding decreased as the SAH concentration increased. Based on the SAH immunoassay, whole immunoassay steps for Hcy detection were carried out in plastic microfluidic chips with all necessary reagents. These experiments demonstrated the feasibility of the Hcy immunoassay in microfluidic devices

  9. In-line electrochemical reagent generation coupled to a flow injection biamperometric system for the determination of sulfite in beverage samples.

    Science.gov (United States)

    de Paula, Nattany T G; Barbosa, Elaine M O; da Silva, Paulo A B; de Souza, Gustavo C S; Nascimento, Valberes B; Lavorante, André F

    2016-07-15

    This work reports an in-line electrochemical reagent generation coupled to a flow injection biamperometric procedure for the determination of SO3(2-). The method was based on a redox reaction between the I3(-) and SO3(2-) ions, after the diffusion of SO2 through a gas diffusion chamber. Under optimum experimental conditions, a linear response ranging from 1.0 to 12.0 mg L(-1) (R=0.9999 and n=7), a detection and quantification limit estimated at 0.26 and 0.86 mg L(-1), respectively, a standard deviation relative of 0.4% (n=10) for a reference solution of 4.0 mg L(-1) SO3(2-) and sampling throughput for 40 determinations per hour were achieved. Addition and recovery tests with juice and wine samples were performed resulting in a range between 92% and 110%. There were no significant differences at a 95% confidence level in the analysis of eight samples when comparing the new method with a reference procedure. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Facile synthesis of aliphatic isothiocyanates and thioureas on solid phase using peptide coupling reagents

    DEFF Research Database (Denmark)

    Boas, Ulrik; Andersen, Heidi Gertz; Christensen, Jørn B.

    2004-01-01

    Peptide coupling reagents can be used as versatile reagents for the formation of aliphatic isothiocyanates and thioureas on solid phase from the corresponding solid-phase anchored aliphatic primary amines. The formation of the thioureas is fast and highly chemoselective, and proceeds via formatio...

  11. Antioxidant properties and cytotoxic effects on human cancer cell lines of aqueous fermented and lipophilic quince (Cydonia oblonga Mill.) preparations.

    Science.gov (United States)

    Pacifico, Severina; Gallicchio, Marialuisa; Fiorentino, Antonio; Fischer, Anna; Meyer, Ulrich; Stintzing, Florian Conrad

    2012-11-01

    In the course of a screening program on quince phytochemicals, two complex preparations were in the focus of the present study, i.e., a lipophilic quince wax extract (QWE) and an aqueous fermented one (QAFE). While the phytochemical composition has been described earlier, the intention of the current investigation was to complement these data with an extensive antioxidant screening of these preparations including their radical scavenging and reductive power as well as their antilipoperoxidative properties. The Quince Aqueous Fermented Extract (QAFE) effectively scavenged the radical target species exhibiting ID(50) values equal to 68.8 μg/mL towards DPPH· and 73.7 μg/mL towards the anion superoxide radical. Quince wax extract (QWE) was more effective at preventing the formation of thiobarbituric reactive species than QAFE exhibiting an ID(50) value equal to 48.9 μg/mL. Moreover the cytotoxic effects towards human HepG2, A549, and HeLa cell lines were evaluated. The two preparations exerted a different effect on the proliferation of the three tested cell lines. Noteworthy, QAFE was almost always more active than QWE but, sometimes, its effects seemed to be strongly dependent on exposure time. Data obtained demonstrate clearly that both hydrophilic and lipophilic quince preparations are non-toxic and exert health-promoting properties. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. 40 CFR 1045.305 - How must I prepare and test my production-line engines?

    Science.gov (United States)

    2010-07-01

    ... production-line engines? 1045.305 Section 1045.305 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Testing Production-line Engines § 1045.305 How must I prepare and test my production-line engines...

  13. 40 CFR 1048.305 - How must I prepare and test my production-line engines?

    Science.gov (United States)

    2010-07-01

    ... production-line engines? 1048.305 Section 1048.305 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW, LARGE NONROAD SPARK-IGNITION ENGINES Testing Production-line Engines § 1048.305 How must I prepare and test my production-line engines? This...

  14. The application of a monolithic triphenylphosphine reagent for conducting Appel reactions in flow microreactors

    Directory of Open Access Journals (Sweden)

    Kimberley A. Roper

    2011-12-01

    Full Text Available Herein we describe the application of a monolithic triphenylphosphine reagent to the Appel reaction in flow-chemistry processing, to generate various brominated products with high purity and in excellent yields, and with no requirement for further off-line purification.

  15. Extraction of uranium(6), transuranium elements and europium by bidentate neutral phosphorus- and phosphorus-nitrogen-containing reagents with substituent in methylene bridge

    International Nuclear Information System (INIS)

    Kochetkova, N.E.; Kojro, O.Eh.; Nesterova, N.P.; Medved', T.Ya.; Chmutova, M.K.; Myasoedov, B.F.; Kabachnik, M.I.

    1986-01-01

    The influence of substituents in methylene bridge on solubility, extractivity and selectivity of bidentate neutral phosphorus- and phosphorus-nitrogen-containing reagents in the process of U(6), TUE, Eu extraction has been studied. It is ascertained that hydrogen substitution in the bridge of tetraphenylmethylenediphosphine dioxide (1) causes a decrease in the extractivity of reagent as to TPE, uranium (6) and europium. There is no visible regular relation between basicity and extractivity of substituted reagents. Hydrogen substitution in the bridge of diphenyl[diethylcarbamoylmethyl]phosphine oxide (2) causes a decrease in extractivity of the reagent as to TPE, uranium (6) and europium. In contrast to monodentate neutral reagents, when bidentate neutral reagents are used, sometimes no increase in the reagent extractivity with an increase in its basicity is observed. When fragments restricting the conformation mobility of bidentate reagent molecule are introduced in it (here substituents in methylene bridge), it may result in the violation of the regularity, since of all the factors affecting the reagent extractivity the spatial factor may become the prevailing one. On hydrogen substitution in the bridge of 1 separation factors of practically all (with few exceptions) studied pairs of elements increase. Hydrogen substitution in the bridge of 2 causes an increase in separation factor of U (6) /Am pair and it does not affect the separation factor of Am/Eu pair. Hydrogen substitution in the bridge of 1 and 2 does not result in the preparation of more efficient and considerably more selective reagents for extractive isolation and separation of the elements, but some of the substituted reagents (Cl-substituted 1, for instance) may turn out useful for the element separation

  16. Development of versatile isotopic labeling reagents for profiling the amine submetabolome by liquid chromatography–mass spectrometry

    International Nuclear Information System (INIS)

    Zhou, Ruokun; Huan, Tao; Li, Liang

    2015-01-01

    Highlights: • Two new reagents were developed for chemical isotope labeling mass spectrometry (MS). • They could be used to label amine-containing metabolites in a metabolomic sample. • The labeled metabolites could be detected with much improved sensitivity in MS. • One of the reagents could also help generate useful MS/MS spectra for structural analysis. • These reagents should be useful for quantitative metabolomics. - Abstract: Metabolomic profiling involves relative quantification of metabolites in comparative samples and identification of the significant metabolites that differentiate different groups (e.g., diseased vs. controls). Chemical isotope labeling (CIL) liquid chromatography–mass spectrometry (LC–MS) is an enabling technique that can provide improved metabolome coverage and metabolite quantification. However, chemical identification of labeled metabolites can still be a challenge. In this work, a new set of isotopic labeling reagents offering versatile properties to enhance both detection and identification are described. They were prepared by a glycine molecule (or its isotopic counterpart) and an aromatic acid with varying structures through a simple three-step synthesis route. In addition to relatively low costs of synthesizing the reagents, this reaction route allows adjusting reagent property in accordance with the desired application objective. To date, two isotopic reagents, 4-dimethylaminobenzoylamido acetic acid N-hydroxylsuccinimide ester (DBAA-NHS) and 4-methoxybenzoylamido acetic acid N-hydroxylsuccinimide ester (MBAA-NHS), for labeling the amine-containing metabolites (i.e., amine submetabolome) have been synthesized. The labeling conditions and the related LC–MS method have been optimized. We demonstrate that DBAA labeling can increase the metabolite detectability because of the presence of an electrospray ionization (ESI)-active dimethylaminobenzoyl group. On the other hand, MBAA labeled metabolites can be fragmented

  17. Development of versatile isotopic labeling reagents for profiling the amine submetabolome by liquid chromatography–mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Ruokun; Huan, Tao; Li, Liang, E-mail: Liang.Li@ualberta.ca

    2015-06-30

    Highlights: • Two new reagents were developed for chemical isotope labeling mass spectrometry (MS). • They could be used to label amine-containing metabolites in a metabolomic sample. • The labeled metabolites could be detected with much improved sensitivity in MS. • One of the reagents could also help generate useful MS/MS spectra for structural analysis. • These reagents should be useful for quantitative metabolomics. - Abstract: Metabolomic profiling involves relative quantification of metabolites in comparative samples and identification of the significant metabolites that differentiate different groups (e.g., diseased vs. controls). Chemical isotope labeling (CIL) liquid chromatography–mass spectrometry (LC–MS) is an enabling technique that can provide improved metabolome coverage and metabolite quantification. However, chemical identification of labeled metabolites can still be a challenge. In this work, a new set of isotopic labeling reagents offering versatile properties to enhance both detection and identification are described. They were prepared by a glycine molecule (or its isotopic counterpart) and an aromatic acid with varying structures through a simple three-step synthesis route. In addition to relatively low costs of synthesizing the reagents, this reaction route allows adjusting reagent property in accordance with the desired application objective. To date, two isotopic reagents, 4-dimethylaminobenzoylamido acetic acid N-hydroxylsuccinimide ester (DBAA-NHS) and 4-methoxybenzoylamido acetic acid N-hydroxylsuccinimide ester (MBAA-NHS), for labeling the amine-containing metabolites (i.e., amine submetabolome) have been synthesized. The labeling conditions and the related LC–MS method have been optimized. We demonstrate that DBAA labeling can increase the metabolite detectability because of the presence of an electrospray ionization (ESI)-active dimethylaminobenzoyl group. On the other hand, MBAA labeled metabolites can be fragmented

  18. A convenient method to synthesize N-[[sup 3]H]methyl-N-nitrosocarbamate transfer reagents

    Energy Technology Data Exchange (ETDEWEB)

    Mehta, P.; Gold, B. (Nebraska Univ., Omaha, NE (United States). Eppley Inst. for Research in Cancer); Konakahara, T. (Science Univiversity of Tokyo, Noda, Chiba (Japan). Faculty of Science and Technology)

    1992-11-01

    Activated N-alkyl-N-nitrosocarbamates are useful acyl transfer reagents that are employed in the synthesis of N-alkyl-N-nitrosoureas and related N-nitroso compounds. The nitrosourea products are of chemical and biological interest because they provide access to the in situ generation of highly reactive carbonium type intermediates, which, depending on their structure, can be powerful carcinogens or antineoplastic agents. The availability of radiolabeled nitrosoureas greatly facilitates studies on their chemical and biological activities. Generally, the synthesis of activated nitrosocarbamates requires condensation of radiolabeled alkylisocyanates with the appropriate alcohol. Because radiolabeled alkylisocyanates are not commercially available and/or troublesome to synthesize, we have developed an easy and economical method for preparing N-[[sup 3]H]methyl-N-nitrosocarbamates suitable for use as transfer reagents utilizing 1,2,2,2-tetrachloroethyl chloroformate and [[sup 3]H]methylamine hydrochloride as starting materials. (author).

  19. On-line comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for preparative isolation of Peucedanum praeruptorum.

    Science.gov (United States)

    Wang, Xin-Yuan; Li, Jia-Fu; Jian, Ya-Mei; Wu, Zhen; Fang, Mei-Juan; Qiu, Ying-Kun

    2015-03-27

    A new on-line comprehensive preparative two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was developed for the separation of complicated natural products. It was based on the use of a silica gel packed medium-pressure column as the first dimension and an ODS preparative HPLC column as the second dimension. The two dimensions were connected with normal-phase (NP) and reversed-phase (RP) enrichment units, involving a newly developed airflow assisted adsorption (AAA) technique. The instrument operation and the performance of this NPLC × RPLC separation method were illustrated by gram-scale isolation of ethanol extract from the roots of Peucedanum praeruptorum. In total, 19 compounds with high purity were obtained via automated multi-step preparative separation in a short period of time using this system, and their structures were comprehensively characterized by ESI-MS, (1)H NMR, and (13)C NMR. Including two new compounds, five isomers in two groups with identical HPLC and TLC retention values were also obtained and identified by 1D NMR and 2D NMR. This is the first report of an NPLC × RPLC system successfully applied in an on-line preparative process. This system not only solved the interfacing problem of mobile-phase immiscibility caused by NP and RP separation, it also exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Physically absorbable reagents-collectors in elementary flotation

    Energy Technology Data Exchange (ETDEWEB)

    S.A. Kondrat' ev; I.G. Bochkarev [Russian Academy of Sciences, Novosibirsk (Russian Federation). Institute of Mining

    2007-09-15

    Based on the reviewed researches held at the Institute of Mining, Siberian Branch, Russian Academy of Sciences, the effect of physically absorbable reagents-collectors on formation of a flotation complex and its stability in turbulent pulp flows in flotation machines of basic types is considered. The basic requirements for physically absorbable reagents-collectors at different flotation stages are established.

  1. Preparation and evaluation of primary reagents for the radioimmunoassay of prolactin hormone as a diagnostic marker for some clinical applications

    International Nuclear Information System (INIS)

    Ebeid, N.H.A.

    2010-01-01

    The preparation of high technology radioimmunoassay (RIA) reagents with low cost is considered to be one of the main objectives of the present study. This may be extremely helpful in diagnosis and treatment of disorders of the anterior pituitary gland or the hypothalamus portion of the brain. The local prolactin (PRL) liquid-phase and solid-phase RIA systems were prepared for the invitro assessment of human prolactin in human serum i.e., (hyperprolactinemia, can occur as a result of pituitary adenomas and hypoprolactinemia are observed in cases of hypopituitarism).The objectives of the present work were designed to achieve: -The production of PRL polyclonal antibodies , PRL standards and radiolabeled PRL tracers. - Optimization of local radioimmunoassay methods (liquid phase - double antibody and solid phase - cellulose particles). - Validation studies of the local assay were carried out using the performance characteristics of the succeeded immunoassays. In the present study, liquid phase and solid phase RIA systems for measurement of PRL proved to be specific, sensitive, precise and accurate. This may suggest that, the liquid and solid phase RIA techniques should be suited for routine laboratory use and have been used effectively in the diagnosis and treatment of patient with pituitary dysfunctions and possible reproductive disability.

  2. 21 CFR 866.3350 - Leptospira spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Leptospira spp. serological reagents. 866.3350... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3350 Leptospira spp. serological reagents. (a) Identification. Leptospira spp. serological reagents are devices that...

  3. 21 CFR 866.3200 - Echinococcus spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Echinococcus spp. serological reagents. 866.3200... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3200 Echinococcus spp. serological reagents. (a) Identification. Echinococcus spp. serological reagents are devices that...

  4. 21 CFR 866.3415 - Pseudomonas spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pseudomonas spp. serological reagents. 866.3415... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3415 Pseudomonas spp. serological reagents. (a) Identification. Pseudomonas spp. serological reagents are devices that...

  5. On some investigation features of sorption of flotation reagents labelled by soft β-emitters on mineral surface

    International Nuclear Information System (INIS)

    Korobochkin, V.P.; Gladyshev, V.P.; Latypova, O.A.

    1983-01-01

    A correction for self-absorption, taking into account concrete dimensions of mineral grain during sorption of flotation reagents on mineral surface is deduced. On the basis of the regularity obtained problems of the sensitivity of the determination method of reagent activity sorbed by minerals which are labelled by radioactive isotopes are considered. Improved technique is described and statistical analysis of the experimental data obtained is carried out

  6. General-purpose chemical analyzer for on-line analyses of radioactive solutions

    International Nuclear Information System (INIS)

    Spencer, W.A.; Kronberg, J.W.

    1983-01-01

    An automated analyzer is being developed to perform analytical measurements on radioactive solutions on-line in a hostile environment. This General Purpose Chemical Analyzer (GPCA) samples a process stream, adds reagents, measures solution absorbances or electrode potentials, and automatically calculates the results. The use of modular components, under microprocessor control, permits a single analyzer design to carry out many types of analyses. This paper discusses the more important design criteria for the GPCA, and describes the equipment being tested in a prototype unit

  7. NMR-based Enantiodifferentiation of Chiral trans-2-Phenylcyclopropane Derivatives Using a Chiral Lanthanide Shift Reagent

    International Nuclear Information System (INIS)

    Cho, Nam Sook; Kim, Hyun Sook; Song, Mi Sook

    2011-01-01

    In contrast with optical methods, there is no need to characterize the pure enantiomers. Instead, the NMR method makes use of chiral reagents that convert a mixture of enantiomers into a mixture of diastereomeric complexes. Integration of the resulting NMR spectra yields a direct measurement of enantiomeric purity as long as there is a sufficiently large difference between the chemical shifts of the two diastereoisomeric complexes to produce baseline-resolved peaks. Absolute enantiomeric configurations can also be determined using this method. Chiral lanthanide shift reagents have been used since the 1970s to form addition complexes with various compounds through interactions with electron donor sites. Lanthanide-induced, pseudo-contact shifts (LIS) are a function of the distance, r, between the nuclei under observation and the lanthanide center, and the angle, θ, between the line connecting the metal ion with the observed nucleus and the line representing the CLSR magnetic axis

  8. Constructing New Bioorthogonal Reagents and Reactions.

    Science.gov (United States)

    Row, R David; Prescher, Jennifer A

    2018-05-15

    Chemical tools are transforming our understanding of biomolecules and living systems. Included in this group are bioorthogonal reagents-functional groups that are inert to most biological species, but can be selectively ligated with complementary probes, even in live cells and whole organisms. Applications of these tools have revealed fundamental new insights into biomolecule structure and function-information often beyond the reach of genetic approaches. In many cases, the knowledge gained from bioorthogonal probes has enabled new questions to be asked and innovative research to be pursued. Thus, the continued development and application of these tools promises to both refine our view of biological systems and facilitate new discoveries. Despite decades of achievements in bioorthogonal chemistry, limitations remain. Several reagents are too large or insufficiently stable for use in cellular environments. Many bioorthogonal groups also cross-react with one another, restricting them to singular tasks. In this Account, we describe our work to address some of the voids in the bioorthogonal toolbox. Our efforts to date have focused on small reagents with a high degree of tunability: cyclopropenes, triazines, and cyclopropenones. These motifs react selectively with complementary reagents, and their unique features are enabling new pursuits in biology. The Account is organized by common themes that emerged in our development of novel bioorthogonal reagents and reactions. First, natural product structures can serve as valuable starting points for probe design. Cyclopropene, triazine, and cyclopropenone motifs are all found in natural products, suggesting that they would be metabolically stable and compatible with a variety of living systems. Second, fine-tuning bioorthogonal reagents is essential for their successful translation to biological systems. Different applications demand different types of probes; thus, generating a collection of tools that span a continuum of

  9. A reagent for processing drilling muds

    Energy Technology Data Exchange (ETDEWEB)

    Polyakov, G.A.; Khon-Pak, A.T.; Khon, A.V.; Normatov, L.N.; Telegin, B.V.

    1983-01-01

    A reagent is proposed for processing drilling muds. It contains an acrylic polymer and potassium permanganate. The reagent is distinguished by the fact that in order to improve the quality of the drilling muds by increasing their salt resistance, the reagent contains hydrolized nitron fiber as the acrylic polymer with the following component relationship (in percent by weight): potassium permanganate, 0.015 to 0.065 and hydrolyzed nitron fiber, the remainder.

  10. Industrial detergent wastewater treatment via fenton reagent

    International Nuclear Information System (INIS)

    Mohd Zairie Mohd Yusuff; Mohd Zulkifli Mohamad Noor; Izirwan Izhab

    2010-01-01

    Production of detergent can generates wastewater containing an organic matter with will consume an oxidation demand, surfactants, suspended solids, fat and oil. Besides, sulfate concentration is high in the most detergent plant effluent because of the sulphonation process that has physiological and toxic effects on marine organisms. Therefore, a research must be conducted to find the solution for this problem. The feasibility of Fentons reagent to treat detergent waste was investigated in this study. The sample of detergent wastewater was taken from FPG Oleo chemicals Sdn. Bhd. This experiment studied the effect of temperature towards the feasibility of Fentons reagent process besides the dosage between hydrogen peroxide (H 2 O 2 ) and ferrous ion (Fe 2+ ) in the reagent. While, evaluated efficiency of Fentons reagent in term of chemical oxygen demand (COD), total suspended solid (TSS) and the turbidity reduction within the experimental design. The result found that overall removal was achieved until 96.2 % in term of COD, 98.1 % in term of TSS and 99.6 % in term of turbidity using Fentons reagent process. Besides, also found that this process is optimum at temperature 35 degree Celsius are able to achieve the Standard A of Parameter Limit of Effluent of Standard A and Standard B were outlined by Department of Environment Malaysia (DOE) based on Environment Quality Act 1974. (author)

  11. Small scale extraction and purification of human prolactin for the preparation of radioimmunoassay reagents

    International Nuclear Information System (INIS)

    Dias, L.E.M.F.

    1989-01-01

    Purification of human prolactin from pituitaries was carried out in our laboratory to obtain a pure reagent for use in RIA. The extraction and purification procedure was adapted from the method of Mc. Lean et al., and it involves the following steps: 1. Extraction of frozen pituitaries in buffers 0.14M phosphate/citrate pH 4.0 and 0.05M ammonium acetate pH 10.0. 2. Purification by hydrophobic interaction chromatography on Phenyl-Sepharose CL-4B in the presence of acetonitrile. 3. Purification by anion exchange chromatography on DEAE-Sepharose Cl-68. The purification method is considered effective for obtaining a hPrl of the purity needed for radioassay purposes, having the advantage of rapidity and relative simplicity. (author) [pt

  12. [Automated analysis of bacterial preparations manufactured on automatic heat fixation and staining equipment].

    Science.gov (United States)

    2012-01-01

    Heat fixation of preparations was made in the fixation bath designed by EMKO (Russia). Programmable "Emkosteiner" (EMKO, Russia) was used for trial staining. Reagents set Micko-GRAM-NITsF was applied for Gram's method of staining. It was demostrated that automatic smear fixation equipment and programmable staining ensure high-quality imaging (1% chromaticity variation) good enough for standardization of Gram's staining of microbial preparations.

  13. 21 CFR 864.8100 - Bothrops atrox reagent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bothrops atrox reagent. 864.8100 Section 864.8100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8100 Bothrops atrox reagent. (a...

  14. Development of IRMA reagent and methodology for PSA

    International Nuclear Information System (INIS)

    Najafi, R.

    1997-01-01

    The PSA test is a solid phase two-site immunoassay. Rabbit anti PSA is coated or bound on surface of solid phase and monoclonal anti PSA labeled with 1-125. The PSA molecules present in the standard solution or serum are 'Sandwiched' between the two antibodies. After formation of coated antibody-antigen-labeled antibody complex, the unbound labeled antibody will removed by washing. The complex is measured by gamma counter. The concentration of analyte is proportional to the counts of test sample. In order to develop kits for IRMA PSA, it should be prepared three essential reagents Antibody coated solid phase, labeled antibody, standards and finally optimizing them to obtain an standard curve fit to measure specimen PSA in desired range of concentration. The type of solid phase and procedure(s) to coat or bind to antibody, is still main debatable subject in development and setting up RIA/IRMA kits. In our experiments, polystyrene beads, because of their easy to coat with antibody as well as easy to use, can be considered as a desired solid phase. Most antibodies are passively adsorbed to a plastic surface (e.g. Polystyrene, Propylene, and Polyvinyl chloride) from a diluted buffer. The antibody coated plastic surface, then acts as solid phase reagent. Poor efficiency and time required to reach equilibrium and also lack of reproducibility especially batch-to-batch variation between materials, are disadvantages in this simple coating procedure. Improvements can be made by coating second antibody on surface of beads, and reaction between second and primary antibodies. There is also possible to enhance more coating efficiency of beads by using Staphylococcus ureus-Protein A. Protein A is a major component of staphylococcus aureus cell wall which has an affinity for FC segment of immunoglobulin G (IgG) of some species, including human; rabbit; and mice. This property of Staphylococcal Protein A has made it a very useful tool in the purification of classes and subclasses

  15. Development of reagents for radioimmunoassay of: triiodothyronine, thyroxine and thyrotrophin

    International Nuclear Information System (INIS)

    Delgado S, B.; Lavalley E, C.; Ruiz J, A.; Garcia F, C.; Zamorano A, F.

    1991-12-01

    The radioimmunoassay (RIA) of thyroid hormones it is the but it frequents of all the studies carried out by RIA in the laboratories of Nuclear Medicine, these essays are carried out with imported reagents. In the ININ the reagents and the necessary methodology have been developed for the triiodothyronine (T3), thyroxine (T4) and thyrotrophin (TSH). The good titles of the antibodies (Ac) primary for each hormone were of 1:4,000; 1:750 and 1:1,500. The used separation system was of double Ac with PEG to 10%, with titles of 1:10 for the second Ac of lamb. The specific activity for 125-I-T3 and 125-I-T4 oscillate between 850 at 900 μCi / μ g: being this of 90 μ Ci /μg for TSH. To the first two hormones they were added 1-8 aniline naftalen sulfonic acid (ANS) to concentrations of 3 and 2 mg/ml respectively. As buffer for T3 and T4 it was used Tris-HCl pH 8.6 and PBS with normal serum of rabbit (SNC) for TSH. The standards got ready in buffer or free serum of thyroid hormones. The slope of the standard curves varied between -2.3 to -2.7 and the variation intra and inter assay among 4 to 10%. It is had at the moment in the ININ with standardized reagents for the RIA of T3, T4 and TSH, it is hoped to carry out tests in other laboratories and to establish the conditions of stability more appropriate to begin the preparation of pilot reagents. (Author)

  16. Development of national immunoassay reagent programmes

    International Nuclear Information System (INIS)

    Sufi, S.B.; Micallef, J.V.; Ahsan, R.; Goncharov, N.P.

    1992-01-01

    Despite the existence of networks of fully equipped laboratories with well-trained staff, the availability of immunodiagnostic services in developing countries is often limited by the high cost of imported kits. There are a number of ways of tackling this problem, ranging from bulk purchase of kits or reagents to local development and production of assay systems. Argentina/Chile, China, Cuba/Mexico, and Thailand are amongst the countries which have established local immunoassay reagent programmes to manufacture low cost, high quality immunoassay reagents. Kits from these projects are now beginning to become available, and it is hoped that they will promote national diagnostic services and research, as well as stimulating the development of reagent programmes for other analytes. (author). 4 refs, 1 tab

  17. 21 CFR 864.4400 - Enzyme preparations.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Enzyme preparations. 864.4400 Section 864.4400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Specimen Preparation Reagents § 864.4400 Enzyme...

  18. A review of reagents for fluorescence microscopy of cellular compartments and structures, Part III: reagents for actin, tubulin, cellular membranes, and whole cell and cytoplasm.

    Science.gov (United States)

    Kilgore, Jason A; Dolman, Nick J; Davidson, Michael W

    2014-01-02

    Non-antibody commercial fluorescent reagents for imaging of cytoskeletal structures have been limited primarily to tubulin and actin, with the main factor in choice based mainly on whether cells are live or fixed and permeabilized. A wider range of options exist for cell membrane dyes, and the choice of reagent primarily depends on the preferred localization in the cell (i.e., all membranes or only the plasma membrane) and usage (i.e., whether the protocol involves fixation and permeabilization). For whole-cell or cytoplasmic imaging, the choice of reagent is determined mostly by the length of time that the cells need to be visualized (hours or days) and by fixation status. Presented here is a discussion on choosing commercially available reagents for these cellular structures, with an emphasis on use for microscopic imaging, with a featured reagent for each structure, a recommended protocol, troubleshooting guide, and example image. Copyright © 2014 John Wiley & Sons, Inc.

  19. New data on masking reagents in complexometry

    International Nuclear Information System (INIS)

    Yurist, I.M.; Talmud, M.M.; Zajtsev, P.M.

    1985-01-01

    Recent literature data on employing inorganic and organic oxygen-, nitrogen- and sulfur-containing substances as masking reagents (MR) in complexonometry of alkali earths, rare earths and transition elements are reviewed for the period of 1971-1983. Effectiveness of any type of MR is shown to be dependent on the electron configuration of a cation being masked. Sr, La, Th, V(6), Zr, Hf, V(5), Nb(5), Ta(5), Mo(6), W(6) a.o. are masked by oxygen-containing ligands. Zn, Cd, Fe(2, 3), Co(2, 3), Ni, etc. are masked by nitrogen- and sulfur-bearing ligands. Thiocompounds mask mainly In, Tl(3), Sn(2), Pb, Bi

  20. High-throughput preparation and testing of ion-exchanged zeolites

    International Nuclear Information System (INIS)

    Janssen, K.P.F.; Paul, J.S.; Sels, B.F.; Jacobs, P.A.

    2007-01-01

    A high-throughput research platform was developed for the preparation and subsequent catalytic liquid-phase screening of ion-exchanged zeolites, for instance with regard to their use as heterogeneous catalysts. In this system aqueous solutions and other liquid as well as solid reagents are employed as starting materials and 24 samples are prepared on a library plate with a 4 x 6 layout. Volumetric dispensing of metal precursor solutions, weighing of zeolite and subsequent mixing/washing cycles of the starting materials and distributing reaction mixtures to the library plate are automatically performed by liquid and solid handlers controlled by a single common and easy-to-use programming software interface. The thus prepared materials are automatically contacted with reagent solutions, heated, stirred and sampled continuously using a modified liquid handling. The high-throughput platform is highly promising in enhancing synthesis of catalysts and their screening. In this paper the preparation of lanthanum-exchanged NaY zeolites (LaNaY) on the platform is reported, along with their use as catalyst for the conversion of renewables

  1. 21 CFR 866.3720 - Streptococcus spp. exo-enzyme reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Streptococcus spp. exo-enzyme reagents. 866.3720... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3720 Streptococcus spp. exo-enzyme reagents. (a) Identification. Streptococcus spp. exoenzyme reagents are devices used...

  2. Inactivation of rabies diagnostic reagents by gamma radiation

    International Nuclear Information System (INIS)

    Gamble, W.C.; Chappell, W.A.; George, E.H.

    1980-01-01

    Treatment of CVS-11 rabies adsorbing suspensions and street rabies infected mouse brains with gamma radiation resulted in inactivated reagents that are safer to distribute and use. These irradiated reagents were as sensitive and reactive as the nonirradiated control reagents

  3. Method for controlled introduction of reagent into a liquid

    Energy Technology Data Exchange (ETDEWEB)

    Newlove, J.C.; McDougall, L.A.

    1988-11-29

    It is an object of this invention to provide a method for using an article to enhance the production of hydrocarbons from geological reservoirs, more particularly from fractured formations. It is an additional object to devise a method for providing controlled release of a reagent downhole, in a pipeline, or in other oil-containing environments or fluids. Thus, there is provided a method for releasing a treating reagent, such as a wax crystal modifier, scale inhibitor, demulsifier, corrosion inhibitor, antioxidant, and biocide, into a liquid hydrocarbon stream. A plurality of porous, substantially wax-free, plastic particles having a softening point above 60/sup 0/C and being chemically resistant to the hydrocarbon stream are placed in the stream. The said particles contain the treating reagent in their pores, said reagent being insoluble in water and in the particles and being leachable on contact with the stream. The hydrocarbon stream is then flowed past said particles and the reagent is leached from the particle pores. In a specific aspect of this invention, a method is provided for recovering crude oil from an underground formation by means of: depositing the aforementioned particles, containing a suitable reagent, downhole in the oil-producing region of the formation; flowing the oil through the deposited particles, thereby leaching the reagent into the oil; and recovering the oil modified by the presence of an active amount of said reagent. Experiments are described to illustrate ways of producing the polymeric particles of the invention and to illustrate the processes of the invention.

  4. Collagen proteins exchange O with demineralisation and gelatinisation reagents and also with atmospheric moisture.

    Science.gov (United States)

    von Holstein, Isabella; von Tersch, Matthew; Coutu, Ashley N; Penkman, Kirsty E H; Makarewicz, Cheryl A; Collins, Matthew J

    2018-01-23

    The oxygen isotope composition of collagen proteins is a potential indicator of adult residential location, useful for provenancing in ecology, archaeology and forensics. In acidic solution, proteins can exchange O from carboxylic acid moieties with reagent O. This study investigated whether this exchange occurs during demineralisation and gelatinisation preparation of bone/ivory collagen. EDTA and HCl demineralisation or gelatinisation reagents were made up in waters with different δ 18 O values, and were used to extract collagen from four skeletal tissue samples. Aliquots of extracted collagen were exposed to two different atmospheric waters, at 120°C and ambient temperature, and subsequently dried in a vacuum oven at 40°C or by freeze drying. Sample δ 18 O values were measured by HT/EA pyrolysis-IRMS using a zero-blank autosampler. Collagen samples exchanged O with both reagent waters and atmospheric water, which altered sample δ 18 O values. Exchange with reagent waters occurred in all extraction methods, but was greater at lower pH. Damage to the collagen samples during extraction increased O exchange. The nature of exchange of O with atmospheric water depended on the temperature of exposure: kinetic fractionation of O was identified at 120°C but not at ambient temperature. Exchange was difficult to quantify due to high variability of δ 18 O value between experimental replicates. Studies of δ 18 O values in collagen proteins should avoid extraction methods using acid solutions. This article is protected by copyright. All rights reserved.

  5. Mentoring Narratives ON-LINE:Teaching the Principalship

    Directory of Open Access Journals (Sweden)

    Allison I. Griffith

    2002-05-01

    Full Text Available The need to develop new models for preparation of school administrators has been a prominent concern in educational discourse in the last decade. Having been criticized for the inadequate preparation of the school leadership cadre, academic departments responsible for training future school administrators have had to revisit their approaches and to reframe their teaching philosophies to ensure the readiness of their graduates for the challenges and complexities of school leadership. This article reports on the new model of principals' training that has been used in York University's Principals' Qualification Program (PQP from the late 1990s onward. One component of the program brings traditional case methodology into a computer-mediated/on-line environment. The on-line cases are narratives from the everyday lives of the Ontario school administrators who serve as mentors in the on-line environment. Situating our discussion within the context of the rapidly changing educational landscape of Ontario, we focus on the PQP model to explore experientially generated case narratives as one method for teaching and learning the work of the local school administrator. We focus particularly on the teaching and learning embedded in computer-mediated or on-line case narratives used in training teachers for school leadership. We argue that the complexities of school leadership—the social, cultural, relational, ethical and moral context of school leadership—can be taught effectively through the reflective processes of on-line case narratives. We seek to contribute to the ongoing dialogue on the potential of new pedagogies and new technologies to help prepare the competent and responsible leaders for tomorrow's schools.

  6. 21 CFR 866.3255 - Escherichia coli serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Escherichia coli serological reagents. 866.3255... coli serological reagents. (a) Identification. Escherichia coli serological reagents are devices that consist of antigens and antisera used in serological tests to identify Escherichia coli from cultured...

  7. Evaluation of novel derivatisation reagents for the analysis of oxysterols

    Energy Technology Data Exchange (ETDEWEB)

    Crick, Peter J., E-mail: p.j.crick@swansea.ac.uk [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Aponte, Jennifer; Bentley, T. William [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Matthews, Ian [College of Engineering, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Wang, Yuqin [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Griffiths, William J., E-mail: w.j.griffiths@swansea.ac.uk [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom)

    2014-04-11

    Graphical abstract: - Highlights: • New derivatisation reagents for LC–MS analysis of oxysterols. • New reagents based on Girard P give high ion-currents and informative LC–MS{sup n} spectra. • Permanent charge is vital for efficient MS{sup n} fragmentation. • New reagents offer greater scope for incorporation of isotope labels. - Abstract: Oxysterols are oxidised forms of cholesterol that are intermediates in the synthesis of bile acids and steroid hormones. They are also ligands to nuclear and G protein-coupled receptors. Analysis of oxysterols in biological systems is challenging due to their low abundance coupled with their lack of a strong chromophore and poor ionisation characteristics in mass spectrometry (MS). We have previously used enzyme-assisted derivatisation for sterol analysis (EADSA) to identify and quantitate oxysterols in biological samples. This technique relies on tagging sterols with the Girard P reagent to introduce a charged quaternary ammonium group. Here, we have compared several modified Girard-like reagents and show that the permanent charge is vital for efficient MS{sup n} fragmentation. However, we find that the reagent can be extended to include sites for potential stable isotope labels without a loss of performance.

  8. Optimization of antibody immobilization for on-line or off-line immunoaffinity chromatography

    DEFF Research Database (Denmark)

    Beyer, Natascha Helena; Schou, Christian; Højrup, Peter

    2009-01-01

    -POROS. Protein G-based matrices are very stable showing essentially no decline in performance after 50 application-wash-elution-reequilibration cycles and being easily prepared within 2-3 h of working time with a typical antibody coupling yield of above 80%. In off-line applications where constant flow....... A systematic study was conducted to determine the most versatile antibody immobilization method for use in on-line and off-line IA chromatography applications using commonly accessible immobilization methods. Four chemistries were examined using polyclonal and monoclonal antibodies and antibody fragments. We...

  9. 21 CFR 864.8540 - Red cell lysing reagent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Red cell lysing reagent. 864.8540 Section 864.8540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8540 Red cell lysing reagent...

  10. Bio-sample detection on paper-based devices with inkjet printer-sprayed reagents.

    Science.gov (United States)

    Liang, Wun-Hong; Chu, Chien-Hung; Yang, Ruey-Jen

    2015-12-01

    The reagent required for bio-sample detection on paper-based analytical devices is generally introduced manually using a pipette. Such an approach is time-consuming; particularly if a large number of devices are required. Automated methods provide a far more convenient solution for large-scale production, but incur a substantial cost. Accordingly, the present study proposes a low-cost method for the paper-based analytical devices in which the biochemical reagents are sprayed onto the device directly using a modified commercial inkjet printer. The feasibility of the proposed method is demonstrated by performing aspartate aminotransferase (AST) and alanine aminotransferase (ALT) tests using simple two-dimensional (2D) paper-based devices. In both cases, the reaction process is analyzed using an image-processing-based colorimetric method. The experimental results show that for AST detection within the 0-105 U/l concentration range, the optimal observation time is around four minutes, while for ALT detection in the 0-125 U/l concentration range, the optimal observation time is approximately one minute. Finally, for both samples, the detection performance of the sprayed-reagent analytical devices is insensitive to the glucose concentration. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. 21 CFR 660.30 - Reagent Red Blood Cells.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Reagent Red Blood Cells. 660.30 Section 660.30...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.30 Reagent Red Blood Cells. (a) Proper name and definition. The proper name of the product shall be...

  12. Reagents and fractions impact on sulphide ore heap bioleaching at Smolnik mine

    Science.gov (United States)

    Oros, L. M.; Zavada, J.

    2017-10-01

    Mine Smolnik is one of the oldest sulphide ore mines in Europe and it is also an important part of bioleaching development. This paper follows previous attempts to extract residual metals from nearby heaps via variations in bioleaching reagents with regard to recent findings and needs in the related industry. Furthermore, economic and process relations between reagents and chosen heap fractions were also investigated in this case study.

  13. An In Vivo Evaluation of the Fit of Zirconium-Oxide Based, Ceramic Single Crowns with Vertical and Horizontal Finish Line Preparations.

    Science.gov (United States)

    Vigolo, Paolo; Mutinelli, Sabrina; Biscaro, Leonello; Stellini, Edoardo

    2015-12-01

    Different types of tooth preparations influence the marginal precision of zirconium-oxide based ceramic single crowns. In this in vivo study, the marginal fits of zirconium-oxide based ceramic single crowns with vertical and horizontal finish lines were compared. Forty-six teeth were chosen in eight patients indicated for extraction for implant placement. CAD/CAM technology was used for the production of 46 zirconium-oxide-based ceramic single crowns: 23 teeth were prepared with vertical finishing lines, 23 with horizontal finishing lines. One operator accomplished all clinical procedures. The zirconia crowns were cemented with glass ionomer cement. The teeth were extracted 1 month later. Marginal gaps along vertical planes were measured for each crown, using a total of four landmarks for each tooth by means of a microscope at 50× magnification. On conclusion of microscopic assessment, ESEM evaluation was completed on all specimens. The comparison of the gap between the two types of preparation was performed with a nonparametric test (two-sample Wilcoxon rank-sum test) with a level of significance fixed at p zirconium-oxide-based ceramic CAD/CAM crowns with vertical and horizontal finish line preparations were not different. © 2015 by the American College of Prosthodontists.

  14. Effect of some colloid surfactants on spectrophotometric characteristics of metal chelates with chromophore organic reagents

    International Nuclear Information System (INIS)

    Chernova, R.K.

    1977-01-01

    Theoretical regularities and prospects of using surface active substances (SAS) in spectrophotometric determination of metal ions (including ions of rare-earth elements, transition metals, Be(3)) with chromophore chelating reagents were investigated. The chromophore reagents investigated were pyrocatechol violet, phenolcarboxylic acids of the triarylmethane series, fluorones, phthalexones and azo-compounds. As SAS certain long-chain quaternary ammonium and pyridinium salts (LQAS) were employed. From the results reported it follows that the introduction of LQAS in the system of Mesup(n+)-chromophore reagent is a rather effective method of enhancing the contrast rendition and, in some cases, the sensitivity and selectivity of the reagents. Explanations are suggested as to the factors which cause the changes observed in the contrast of the reactions in the presence of SAS; the underlying phenomena are the ligand-ligand interactions between the organic reagents and SAS and solubilization processes of the reaction products by the micelles of SAS

  15. Hydrazine reagents as derivatizing agents in environmental analysis--a critical review.

    Science.gov (United States)

    Vogel, M; Büldt, A; Karst, U

    2000-04-01

    Hydrazine reagents are a well-known group of derivatizing agents for the determination of aldehydes and ketones in liquid and gaseous samples. Within this article, the most important hydrazine reagents are critically summarized, and their major applications in different fields, including environmental analysis, food chemistry and industrial analysis are introduced. As 2,4-dinitrophenylhydrazine (DNPH) is the basic reagent for several international standard procedures, its properties are discussed in detail. Particular focus is directed on the chemistry of the hydrazine reagents, and chemical interferences are considered. Recent methods for the determination of various oxidants using hydrazine reagents are presented as well. Due to limited space, this review does not cover the related field of carbohydrate analysis, although many chemical aspects are similar.

  16. 125I-labeled crosslinking reagent that is hydrophilic, photoactivatable, and cleavable through an azo linkage

    International Nuclear Information System (INIS)

    Denny, J.B.; Blobel, G.

    1984-01-01

    A radioactive crosslinking reagent, N-[4-(p-azido-m-[ 125 I]iodophenylazo)benzoyl]-3-aminopropyl-N'-oxysulfosuccinimide ester, has been synthesized. The reagent is photoactivatable, water-soluble, cleavable through an azo linkage, and labeled with 125 I at the carrier-free specific activity of 2000 Ci/mmol. Any protein derivatized with the reagent is thus converted into an 125 I-labeled photoaffinity probe. Crosslinks are formed following photolysis with 366-nm light, and cleavage by sodium dithionite results in the donation of radioactivity to the distal partner in crosslinked complexes. The newly labeled proteins are then analyzed by gel electrophoresis and autoradiography. The compound was prepared by iodination of N-[4-(p-aminophenylazo)benzoyl]-3-aminopropionic acid using carrier-free Na 125 I and chloramine-T, followed by azide formation and conversion to the water-soluble sulfosuccinimide ester. As a model system, protein A-Sepharose was derivatized with the reagent under subdued light. Each derivatized protein A molecule contained only one crosslinker. The derivatized protein A-Sepharose was then photolyzed in the presence of human serum and subsequently treated with sodium dithionite. Analysis of the serum by gel electrophoresis revealed that 1.1% of the radioactive label originally present on the protein A-Sepharose was transferred to the heavy chain of IgG, which was the most intensely labeled protein in the gel. The next most intensely labeled protein was IgG light chain, which incorporated radioactivity that was lower by a factor of 3.6 than that of the heavy chain. 36 references, 3 figures

  17. Effect of resin-modified glass-ionomer cement lining and composite layering technique on the adhesive interface of lateral wall

    Directory of Open Access Journals (Sweden)

    Larissa Marinho AZEVEDO

    2015-06-01

    Full Text Available Interface integrity can be maintained by setting the composite in a layering technique and using liners. Objective The aim of this in vitro study was to verify the effect of resin-modified glass-ionomer cement (RMGIC lining and composite layering technique on the bond strength of the dentin/resin adhesive interface of lateral walls of occlusal restorations. Material and Methods Occlusal cavities were prepared in 52 extracted sound human molars, randomly assigned into 4 groups: Group 2H (control – no lining + two horizontal layers; Group 4O: no lining + four oblique layers; Group V-2H: RMGIC lining (Vitrebond + two horizontal layers; and Group V-4O: RMGIC lining (Vitrebond + four oblique layers. Resin composite (Filtek Z250, 3M ESPE was placed after application of an adhesive system (Adper™ Single Bond 2, 3M ESPE dyed with a fluorescent reagent (Rhodamine B to allow confocal microscopy analysis. The teeth were stored in deionized water at 37oC for 24 hours before being sectioned into 0.8 mm slices. One slice of each tooth was randomly selected for Confocal Laser Scanning Microscopy (CLSM analysis. The other slices were sectioned into 0.8 mm x 0.8 mm sticks to microtensile bond strength test (MPa. Data were analyzed by two-way ANOVA and Fisher's test. Results There was no statistical difference on bond strength among groups (p>0.05. CLSM analysis showed no significant statistical difference regarding the presence of gap at the interface dentin/resin among groups. Conclusions RMGIC lining and composite layering techniques showed no effect on the microtensile bond strength and gap formation at the adhesive interface of lateral walls of high C-factor occlusal restorations.

  18. Influence of reagents mixture density on the radiation-thermal synthesis of lithium-zinc ferrites

    Science.gov (United States)

    Surzhikov, A. P.; Lysenko, E. N.; Vlasov, V. A.; Malyshev, A. V.; Korobeynikov, M. V.; Mikhailenko, M. A.

    2017-01-01

    Influence of Li2CO3-ZnO-Fe2O3 powder reagents mixture density on the synthesis efficiency of lithium-zinc ferrites in the conditions of thermal heating or pulsed electron beam heating was studied by X-Ray diffraction and magnetization analysis. The results showed that the including a compaction of powder reagents mixture in ferrite synthesis leads to an increase in concentration of the spinel phase and decrease in initial components content in lithium-substituted ferrites synthesized by thermal or radiation-thermal heating.

  19. New on-line separation workflow of microbial metabolites via hyphenation of analytical and preparative comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Yan, Xia; Wang, Li-Juan; Wu, Zhen; Wu, Yun-Long; Liu, Xiu-Xiu; Chang, Fang-Rong; Fang, Mei-Juan; Qiu, Ying-Kun

    2016-10-15

    Microbial metabolites represent an important source of bioactive natural products, but always exhibit diverse of chemical structures or complicated chemical composition with low active ingredients content. Traditional separation methods rely mainly on off-line combination of open-column chromatography and preparative high performance liquid chromatography (HPLC). However, the multi-step and prolonged separation procedure might lead to exposure to oxygen and structural transformation of metabolites. In the present work, a new two-dimensional separation workflow for fast isolation and analysis of microbial metabolites from Chaetomium globosum SNSHI-5, a cytotoxic fungus derived from extreme environment. The advantage of this analytical comprehensive two-dimensional liquid chromatography (2D-LC) lies on its ability to analyze the composition of the metabolites, and to optimize the separation conditions for the preparative 2D-LC. Furthermore, gram scale preparative 2D-LC separation of the crude fungus extract could be performed on a medium-pressure liquid chromatograph×preparative high-performance liquid chromatography system, under the optimized condition. Interestingly, 12 cytochalasan derivatives, including two new compounds named cytoglobosin Ab (3) and isochaetoglobosin Db (8), were successfully obtained with high purity in a short period of time. The structures of the isolated metabolites were comprehensively characterized by HR ESI-MS and NMR. To be highlighted, this is the first report on the combination of analytical and preparative 2D-LC for the separation of microbial metabolites. The new workflow exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. 40 CFR 1051.305 - How must I prepare and test my production-line vehicles or engines?

    Science.gov (United States)

    2010-07-01

    ... production-line vehicles or engines? 1051.305 Section 1051.305 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM RECREATIONAL ENGINES AND VEHICLES Testing Production-Line Vehicles and Engines § 1051.305 How must I prepare and test my production...

  1. The effect of selected preparation variables on the radiochemical purity of 99mTc-EDDA-HYNIC-TOC

    International Nuclear Information System (INIS)

    Betuel Tasdelen

    2011-01-01

    [ 99m Tc-EDDA-HYNIC-D-Phe 1 , Tyr 3 ]-Ocreotide ( 99m Tc-EDDA-HYNIC-TOC) increasingly emerges to be an alternative tool for somatostatin receptor (SSTR) scintigraphy of neuroendocrine tumours. The high quality of this radiopharmaceutical and its uniformity are very important facts for application of this preparation in clinical practice. Various factors may influence the radiochemical purity (RCP) of certain reagent kits. Some of these include the amount of activity added to the reagent kit, heating time and the age of the formulated kit. The effect of these factors on RCP of 99m Tc-EDDA-HYNIC-TOC has been investigated using high performance liquid chromatography (HPLC) and instant thin layer chromatography (ITLC). (author)

  2. Stability study for magnetic reagent assaying Hb and HbA1c

    International Nuclear Information System (INIS)

    Hsieh, Wen-Pin; Chieh, J.J.; Yang, C.C.; Yang, S.Y.; Chen, Po-Yu; Huang, Yu-Hao; Hong, Y.W.; Horng, H.E.

    2013-01-01

    Reagents for magnetically labeled immunoassay on human Hb and human HbA1c have been synthesized. The reagents consist of Fe 3 O 4 magnetic particles biofunctionalized with antibodies against Hb and HbA1c. It has been demonstrated that the reagents can be applied to quantitatively detect Hb and HbA1c by using immunomagnetic reduction assay. In addition to characterizing the assay properties, such as the standard curve and the low-detection limit, the stability of reagents is investigated. To do this, the temporal dependence of particle sizes and the bio-activity of reagents are monitored. The results show that the reagents are highly stable when stored at 2–8 °C. This means that the reagents synthesized in this work are promising for practical applications. - Highlights: ► The properties of assaying Hb and HbA1c using immunomagnetic reduction are studied. ► The magnetic nanoparticles with antibodies are highly stable in solutions. ► No significant mutual interference between Hb and HbA1c in assays is observed. ► High-sensitivity assays on Hb and HbA1c using immunomagnetic reduction are achieved.

  3. Novel Safranin-Tinted Candida rugosa Lipase Nanoconjugates Reagent for Visualizing Latent Fingerprints on Stainless Steel Knives Immersed in a Natural Outdoor Pond

    Directory of Open Access Journals (Sweden)

    Aida Rasyidah Azman

    2018-05-01

    Full Text Available Waterways are popular locations for the disposition of criminal evidence because the recovery of latent fingerprints from such evidence is difficult. Currently, small particle reagent is a method often used to visualize latent fingerprints containing carcinogenic and hazardous compounds. This study proposes an eco-friendly, safranin-tinted Candida rugosa lipase (triacylglycerol ester hydrolysis EC 3.1.1.3 with functionalized carbon nanotubes (CRL-MWCNTS/GA/SAF as an alternative reagent to the small particle reagent. The CRL-MWCNTS/GA/SAF reagent was compared with the small particle reagent to visualize groomed, full fingerprints deposited on stainless steel knives which were immersed in a natural outdoor pond for 30 days. The quality of visualized fingerprints using the new reagent was similar (modified-Centre for Applied Science and Technology grade: 4; p > 0.05 to small particle reagent, even after 15 days of immersion. Despite the slight decrease in quality of visualized fingerprints using the CRL-MWCNTS/GA/SAF on the last three immersion periods, the fingerprints remained forensically identifiable (modified-Centre for Applied Science and Technology grade: 3. The possible chemical interactions that enabled successful visualization is also discussed. Thus, this novel reagent may provide a relatively greener alternative for the visualization of latent fingerprints on immersed non-porous objects.

  4. High Throughput Sample Preparation and Analysis for DNA Sequencing, PCR and Combinatorial Screening of Catalysis Based on Capillary Array Technique

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yonghua [Iowa State Univ., Ames, IA (United States)

    2000-01-01

    Sample preparation has been one of the major bottlenecks for many high throughput analyses. The purpose of this research was to develop new sample preparation and integration approach for DNA sequencing, PCR based DNA analysis and combinatorial screening of homogeneous catalysis based on multiplexed capillary electrophoresis with laser induced fluorescence or imaging UV absorption detection. The author first introduced a method to integrate the front-end tasks to DNA capillary-array sequencers. protocols for directly sequencing the plasmids from a single bacterial colony in fused-silica capillaries were developed. After the colony was picked, lysis was accomplished in situ in the plastic sample tube using either a thermocycler or heating block. Upon heating, the plasmids were released while chromsomal DNA and membrane proteins were denatured and precipitated to the bottom of the tube. After adding enzyme and Sanger reagents, the resulting solution was aspirated into the reaction capillaries by a syringe pump, and cycle sequencing was initiated. No deleterious effect upon the reaction efficiency, the on-line purification system, or the capillary electrophoresis separation was observed, even though the crude lysate was used as the template. Multiplexed on-line DNA sequencing data from 8 parallel channels allowed base calling up to 620 bp with an accuracy of 98%. The entire system can be automatically regenerated for repeated operation. For PCR based DNA analysis, they demonstrated that capillary electrophoresis with UV detection can be used for DNA analysis starting from clinical sample without purification. After PCR reaction using cheek cell, blood or HIV-1 gag DNA, the reaction mixtures was injected into the capillary either on-line or off-line by base stacking. The protocol was also applied to capillary array electrophoresis. The use of cheaper detection, and the elimination of purification of DNA sample before or after PCR reaction, will make this approach an

  5. 21 CFR 866.3220 - Entamoeba histolytica serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3220... fluorescent dye (immunofluorescent reagents) used to identify Entamoeba histolytica directly from clinical...

  6. 21 CFR 866.3375 - Mycoplasma spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3375 Mycoplasma... fluorescent dye (immunofluorescent reagents) used to identify Mycoplasma spp. directly from clinical specimens...

  7. Preparation of trialkylindium by alkylation of metallic indium

    International Nuclear Information System (INIS)

    Eremeev, I.V.; Danov, S.M.; Sakhipov, V.R.

    1995-01-01

    The investigation results on production of trialkyl indium by alkylation of metallic indium are presented. In contradistinction to the known techniques for the production of trialkyls on indium by alkylation it is suggested to separate the synthesis into two steps. At the first step indium is alkylated by alkylhalide to alkyl indium halide, and at the second alkylation is carried out using. Grignard reagent. The techniques for preparation of trimethyl- and triethylindium, developed on the bases of this scheme, are noted for good reproducibility, allow to preclude, agglomeration of indium during the synthesis, as well as to reduce the consumption coefficients, and amounts, of the introduced starting reagents, i.e. magnesium and alkylhalide. Refs. 16

  8. 21 CFR 866.3780 - Toxoplasma gondii serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3780 Toxoplasma... (immunofluorescent reagents) used to identify Toxoplasma gondii from clinical specimens. The identification aids in...

  9. Stability study for magnetic reagent assaying Hb and HbA1c

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Wen-Pin [Actherm Inc., Hsinchu 200, Taiwan (China); Chieh, J.J.; Yang, C.C. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); Yang, S.Y. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); MagQu Co., Ltd., Sindian Dist., New Taipei City 231, Taiwan (China); Chen, Po-Yu; Huang, Yu-Hao [Actherm Inc., Hsinchu 200, Taiwan (China); Hong, Y.W. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); Horng, H.E., E-mail: phyfv001@ntnu.edu.tw [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China)

    2013-01-15

    Reagents for magnetically labeled immunoassay on human Hb and human HbA1c have been synthesized. The reagents consist of Fe{sub 3}O{sub 4} magnetic particles biofunctionalized with antibodies against Hb and HbA1c. It has been demonstrated that the reagents can be applied to quantitatively detect Hb and HbA1c by using immunomagnetic reduction assay. In addition to characterizing the assay properties, such as the standard curve and the low-detection limit, the stability of reagents is investigated. To do this, the temporal dependence of particle sizes and the bio-activity of reagents are monitored. The results show that the reagents are highly stable when stored at 2-8 Degree-Sign C. This means that the reagents synthesized in this work are promising for practical applications. - Highlights: Black-Right-Pointing-Pointer The properties of assaying Hb and HbA1c using immunomagnetic reduction are studied. Black-Right-Pointing-Pointer The magnetic nanoparticles with antibodies are highly stable in solutions. Black-Right-Pointing-Pointer No significant mutual interference between Hb and HbA1c in assays is observed. Black-Right-Pointing-Pointer High-sensitivity assays on Hb and HbA1c using immunomagnetic reduction are achieved.

  10. 78 FR 33403 - Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental...

    Science.gov (United States)

    2013-06-04

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PF13-5-000] Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Assessment for the Planned Leidy Southeast Expansion Project, Request for Comments on Environmental Issues, and Notice of Public Scoping Meetings The staff of the Federal...

  11. 77 FR 59391 - Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental...

    Science.gov (United States)

    2012-09-27

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP12-497-000] Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Assesment for the Proposed Brandywine Creek Replacement Project; Request for Comments on Environmental Issues; and Notice of Public Scoping Meeting The staff of the Federal...

  12. 75 FR 42738 - Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental...

    Science.gov (United States)

    2010-07-22

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PF10-16-000] Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Assessment for the Planned Mid-Atlantic Connector Expansion Project, Request for Comments on Environmental Issues, and Notice of Public Scoping Meeting July 15, 2010. The...

  13. The influence of reagent type on the kinetics of ultrafine coal flotation

    Science.gov (United States)

    Read, R.B.; Camp, L.R.; Summers, M.S.; Rapp, D.M.

    1989-01-01

    A kinetic study has been conducted to determine the influence of reagent type on flotation rates of ultrafine coal. Two ultrafine coal samples, the Illinois No. 5 (Springfield) and Pittsburgh No. 8, have been evaluated with various reagent types in order to derive the rate constants for coal (kc), ash (ka), and pyrite (kc). The reagents used in the study include anionic surfactants, anionic surfactant-alcohol mixtures, and frothing alcohols. In general, the surfactant-alcohol mixtures tend to float ultrafine coal at a rate three to four times faster than either pure alcohols or pure anionic surfactants. Pine oil, a mixture of terpene alcohols and hydrocarbons, was an exception to this finding; it exhibited higher rate constants than the pure aliphatic alcohols or other pure anionic surfactants studied; this may be explained by the fact that the sample of pine oil used (70% alpha-terpineol) acted as a frother/collector system similar to alcohol/kerosene. The separation efficiencies of ash and pyrite from coal, as evidenced by the ratios of kc/ka or kc/kp, tend to indicate, however, that commercially available surfactant-alcohol mixtures are not as selective as pure alcohols such as 2-ethyl-1-hexanol or methylisobutylcarbinol. Some distinct differences in various rate constants, or their ratios, were noted between the two coals studied, and are possibly attributable to surface chemistry effects. ?? 1989.

  14. Point-of-care Devices: Non-Newtonian Whole Blood Behavior and Capillary Flow on Reagent-coated Walls

    Directory of Open Access Journals (Sweden)

    Jean BERTHIER

    2016-08-01

    Full Text Available Most point-of-care (POC and patient self-testing (PST devices are based on the analysis of whole blood taken from a finger prick. Whole blood contains a bountiful of information about the donor’s health. We analyze here two particularities of microsystems for blood analysis: the blood non-Newtonian behavior, and the capillary flow in reagent-coated channels. Capillarity is the most commonly used method to move fluids in portable systems. It is shown first that the capillary flow of blood does not follow the Lucas-Washburn-Rideal law when the capillary flow velocity is small, due to its non-Newtonian rheology and to the formation of rouleaux of RBCs. In a second step, the capillary flow of blood on reagent-coated surfaces is investigated; first experimentally by observing the spreading of a droplet of blood on different reagent-coated substrates; second theoretically and numerically using the general law for spontaneous capillary flows and the Evolver numerical program.

  15. Cytotoxic effects of Pinus eldarica essential oil and extracts on HeLa and MCF-7 cell lines.

    Science.gov (United States)

    Sarvmeili, Najmeh; Jafarian-Dehkordi, Abbas; Zolfaghari, Behzad

    2016-12-01

    Several attempts have so far been made in the search of new anticancer agents of plant origin. Some studies have reported that different species of Pine genus possess cytotoxic activities against various cancer cell lines. In the present study, we evaluated the cytotoxic effects of Pinus eldarica bark and leaf extracts or leaf essential oil on HeLa and MCF-7 tumor cell lines. Hydroalcoholic and phenolic extracts and the essential oil of plant were prepared. Total phenolic contents of the extracts were measured using Folin-Ciocalteu reagent. Essential oil components were determined by gas chromatography-mass spectroscopy (GC-MS). Cytotoxic activity of the extracts and essential oil against HeLa and MCF-7 tumor cell lines were assessed by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay. The polyphenolic content of hydroalcoholic and phenolic extracts of the bark and hydroalcoholic extract of the leaf were 48.31%, 47.2%, and 8.47%, respectively. According to the GC-MS analysis, the major components of the leaf oil of P. eldarica were: β -caryophyllene (14.8%), germacrene D (12.9%), α-terpinenyl acetate (8.15%), α -pinene (5.7%), and -α humulene (5.9%). Bark extracts and leaf essential oil of P. eldarica significantly reduced the viability of both HeLa and MCF-7 cells in a concentration dependent manner. However, leaf extract showed less inhibitory effects against both cell lines. The essential oil of P. eldarica was more cytotoxic than its hydroalcoholic and phenolic extracts. The terpenes and phenolic compounds were probably responsible for cytotoxicity of P. eldarica . Therefore, P. eldarica might have a good potential for active anticancer agents.

  16. A new graphite preparation line for AMS 14C dating in the Zagreb Radiocarbon Laboratory

    Science.gov (United States)

    Krajcar Bronić, I.; Horvatinčić, N.; Sironić, A.; Obelić, B.; Barešić, J.; Felja, I.

    2010-04-01

    The new line for preparation of graphite samples for 14C dating by AMS has been constructed in the Zagreb Radiocarbon Laboratory. The performance of the rig and sample preparation procedure has been validated by preparing graphites from various reference materials of known 14C activity. The yield of the graphitization was good and the measured fraction of modern carbon ( Fm) values have not significantly deviated from the expected ones. Detailed analysis of measured Fm values indicates a slight bias to more positive values and should be carefully investigated.

  17. Investigation of cleaning reagents for calcium chromate spills

    International Nuclear Information System (INIS)

    Dillard, B.M.

    1979-01-01

    Cleaning of calcium chromate spills can be a problem due to the insolubility of the material and the corrosiveness of several possible cleaning agents on the stainless steel equipment. Because of OSHA Standards for Cr(VI) exposure, it is necessary to remove spills as efficiently as possible in order to prevent the contaminant from becoming airborne. This study involved the comparison of several possible cleaning agents by studying the solubility of calcium chromate in each reagent. Two general types of reagents for dissolution of calcium chromate were investigated; those which act by conversion of the insoluble calcium chromate to a more soluble salt and to H 2 CrO 4 , and those which appear to act as complexing agents and thereby dissolve the calcium chromate. The most efficient of the reagents investigated was hydrochloric acid. However, even dilute solutions of halide acids destroy passivity of stainless steel causing pitting and stress-corrosion. Acetic acid and nitric acid were somewhat less efficient than hydrochloric acid in dissolving calcium chromate. However, both reagents are noncorrosive with stainless steel, nitric acid tending to favor passivity of the materials. Therefore, it is recommended that dilute solutions of either of these two acids be used for removal of calcium chromate spills in conjunction with mechanical methods that might be necessary, depending on the magnitude of the spill

  18. [Comparative analysis of 3D data visibility of the prepared tooth finishing line on a synthetic jaw model, captured by international scanners in a laboratory conditions].

    Science.gov (United States)

    Ryakhovskiy, A N; Kostyukova, V V

    The aim of the study was to compare accuracy of digital impression's finishing line and the zone under it taken by different intraoral scanning systems. Parameters of comparison were: different level of the finishing line to the gingiva and width of sulcus after retraction. For this purpose two synthetic jaw models with prepared teeth were scanned using intraoral scanning systems: 3D Progress (MHT S.P.A., IT - MHT Optic Research AG, CH); True Definition (3M ESPE, USA); Trios (3Shape A/S, DNK); CEREC AC Bluecam, CEREC Omnicam (Sirona Dental System GmbH, DE); Planscan (Planmeca, FIN) (each n=10). Reference-scanning was done by ATOS Core (GOM mbH, DE). The resulting digital impressions were superimposed with the master-scan. The lowest measured deviations (trueness) for intraoral scanners, where the finishing line was 0.5 mm above gingiva were with scanner True Definition - 18.8±6.63 (on the finishing line) and 51.0±14.33 µm (0.3 mm under the finishing line). In conditions where finishing line was on the same level with gingiva, scanner Trios showed the best results: 17.0±3.96 and 52.7±6.52 µm. When the finishing line was 0.5 mm under gingiva, none of the testing scanners could visualize the zone 0.3 mm lower the finishing line. The best results for accuracy o the finishing line in that circumstances showed Trios: 15.1±5.05 µm. The optimum visualization of the finishing line and the zone under it was reached when the sulcus was 0.3 mm after retraction. Thus, the best accuracy was obtained with Trios: 10.3±2.69 (on the finishing line) and 57.2±13.58 µm (0.3 mm under finishing line). The results show that intraoral scanners also provide enough accuracy for indicating finishing line and the zone under it in different conditions of preparation and gingiva retraction. However, not all of the testing scanners can properly indicate finishing line and the zone under it when shoulder is below gingiva and the width of sulcus is less than 0.2 mm.

  19. 76 FR 40717 - Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental...

    Science.gov (United States)

    2011-07-11

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PF11-4-000] Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Assessment for the Planned Northeast Supply Link Project, Request for Comments on Environmental Issues, and Notice of Public Scoping Meetings The staff of the Federal Energy...

  20. Reverse flow injection spectrophotometric determination of ciprofloxacin in pharmaceuticals using iron from soil as a green reagent

    Science.gov (United States)

    Palamy, Sysay; Ruengsitagoon, Wirat

    2018-02-01

    A novel reverse flow injection spectrophotometric method for the determination of ciprofloxacin was successfully combined with the on-line introduction of an iron solution extracted from soil as green reagent. The assay was optimized by a univariate method to select the optimum conditions for the highest absorbance and highest stability of the complex. Beer-Lambert's law (λmax = 440 nm) is obeyed in the range 0.5-50 μg mL- 1 with a correlation coefficient (r2) of 0.9976 and 0.9996 using soil as green reagent from Khon Kaen, Thailand and Vientiane, Laos, respectively. The average percentage recoveries were in the range of 98.55-102.14% and the precision was in the range of 0.80-1.73%. The limit of detection and the limit of quantitation were 0.20 and 0.69 μg mL- 1, respectively, with a sampling rate of over 46 samples h- 1. The method was successfully applied to the determination of ciprofloxacin in commercial pharmaceutical formulations. The results were in good agreement with those obtained by the reference HPLC method using a t-test at 95% of confidence level for comparison. This method is suitable for laboratories looking for alternative analytical methods using green reagents.

  1. A review of reagents for fluorescence microscopy of cellular compartments and structures, part I: BacMam labeling and reagents for vesicular structures.

    Science.gov (United States)

    Dolman, Nick J; Kilgore, Jason A; Davidson, Michael W

    2013-07-01

    Fluorescent labeling of vesicular structures in cultured cells, particularly for live cells, can be challenging for a number of reasons. The first challenge is to identify a reagent that will be specific enough where some structures have a number of potential reagents and others very few options. The emergence of BacMam constructs has allowed more easy-to-use choices. Presented here is a discussion of BacMam constructs as well as a review of commercially-available reagents for labeling vesicular structures in cells, including endosomes, peroxisomes, lysosomes, and autophagosomes, complete with a featured reagent for each structure, recommended protocol, troubleshooting guide, and example image. © 2013 by John Wiley & Sons, Inc.

  2. An automated method for the analysis of phenolic acids in plasma based on ion-pairing micro-extraction coupled on-line to gas chromatography/mass spectrometry with in-liner derivatisation

    NARCIS (Netherlands)

    Peters, S.; Kaal, E.; Horsting, I.; Janssen, H.-G.

    2012-01-01

    A new method is presented for the analysis of phenolic acids in plasma based on ion-pairing ‘Micro-extraction in packed sorbent’ (MEPS) coupled on-line to in-liner derivatisation-gas chromatography-mass spectrometry (GC-MS). The ion-pairing reagent served a dual purpose. It was used both to improve

  3. Field-Portable Immunoassay Instruments and Reagents to Measure Chelators and Mobile Forms of Uranium

    International Nuclear Information System (INIS)

    Blake, Diane A.

    2003-01-01

    The goals for the 3-year project period are (1) to test and validate the present uranium sensor and develop protocols for its use at the NABIR Field Research Center; (2) to develop new reagents that will provide superior performance for the present hand-held immunosensor; and (3) to develop new antibodies that will permit this sensor to also measure other environmental contaminants (chromium, mercury, and/or DTPA). Sensor design modifications are underway via international collaborations. New reagents that will provide superior performance for the present hand-held immunosensor are being prepared and tested. New methods have been developed, to produce recombinant forms of metal-specific monoclonal antibodies for use with the sensor. Site-directed mutagenesis experiments are underway to determine the mechanisms of binding. Immunization experiments with sheep and rabbits to develop new recombinant forms of antibodies to metal-chelate complexes (chromium, mercury, and/or DTPA) have been initiated

  4. An on-line dilution system for spectrometry using an inductively coupled plasma source

    International Nuclear Information System (INIS)

    Moore, G.L.; Watson, A.E.; Humphries-Cuff, P.J.

    1982-01-01

    An on-line dilution system that uses a two-channel peristaltic pump to feed a GMK Babington type of nebulizer is described. By the use of a diluent containing the appropriate concentrations of acid, sodium, and internal standard element, which was fed at a constant rate to the nebulizer, the system produced analytical results that are not significantly different (less than 3 per cent relative) from those obtained with the normal dilution technique. However, a considerable saving in time is achieved, as well as a saving in the use of expensive reagents

  5. Preparation of ore blocks for mine leaching by reagent explosion injection

    Science.gov (United States)

    Shevchenko, YuS

    2017-02-01

    The current drilling-and-blasting operations fail to prepare intact ore body underlying a production horizon for subsequent mining and leaching. It is found that the required preparation quality is possible by means of advanced implementation of ore body discontinuity and filling of the resultant system of joints with active leaching solutions.

  6. Improved characterization of EV preparations based on protein to lipid ratio and lipid properties.

    Directory of Open Access Journals (Sweden)

    Xabier Osteikoetxea

    Full Text Available In recent years the study of extracellular vesicles has gathered much scientific and clinical interest. As the field is expanding, it is becoming clear that better methods for characterization and quantification of extracellular vesicles as well as better standards to compare studies are warranted. The goal of the present work was to find improved parameters to characterize extracellular vesicle preparations. Here we introduce a simple 96 well plate-based total lipid assay for determination of lipid content and protein to lipid ratios of extracellular vesicle preparations from various myeloid and lymphoid cell lines as well as blood plasma. These preparations included apoptotic bodies, microvesicles/microparticles, and exosomes isolated by size-based fractionation. We also investigated lipid bilayer order of extracellular vesicle subpopulations using Di-4-ANEPPDHQ lipid probe, and lipid composition using affinity reagents to clustered cholesterol (monoclonal anti-cholesterol antibody and ganglioside GM1 (cholera toxin subunit B. We have consistently found different protein to lipid ratios characteristic for the investigated extracellular vesicle subpopulations which were substantially altered in the case of vesicular damage or protein contamination. Spectral ratiometric imaging and flow cytometric analysis also revealed marked differences between the various vesicle populations in their lipid order and their clustered membrane cholesterol and GM1 content. Our study introduces for the first time a simple and readily available lipid assay to complement the widely used protein assays in order to better characterize extracellular vesicle preparations. Besides differentiating extracellular vesicle subpopulations, the novel parameters introduced in this work (protein to lipid ratio, lipid bilayer order, and lipid composition, may prove useful for quality control of extracellular vesicle related basic and clinical studies.

  7. A Snippet of Grignard Reagent's Histroy There are very few reagents ...

    Indian Academy of Sciences (India)

    IAS Admin

    with bromine, (eq.1). But he failed to notice the formation of phenylmagnesium bromide, because he was using excess bromine which destroyed it. Hence, he could isolate only bromobenzene,. (eq.2). Had he used only one molar equivalent of bromine, perhaps the organomagnesium reagent would bear his name today.

  8. Azidoimidazolinium Salts: Safe and Efficient Diazo-transfer Reagents and Unique Azido-donors.

    Science.gov (United States)

    Kitamura, Mitsuru

    2017-07-01

    2-Azido-1,3-dimethylimidazolinium chloride (ADMC) and its corresponding hexafluorophosphate (ADMP) were found to be efficient diazo-transfer reagents to various organic compounds. ADMC was prepared by the reaction of 2-chloro-1,3-dimethylimidazolinium chloride (DMC) and sodium azide. ADMP was isolated as a crystal having good thermal stability and low explosibility. ADMC and ADMP reacted with 1,3-dicarbonyl compounds under mild basic conditions to give 2-diazo-1,3-dicarbonyl compounds in high yields, which were easily isolated in virtue of the high water solubility of the by-products. ADMP showed high diazo-transfer ability to primary amines even in the absence of metal salt such as Cu(II). Using this diazotization approach, various alkyl/aryl azides were directly obtained from their corresponding primary amines in high yields. Furthermore, naphthols reacted with ADMC to give the corresponding diazonaphthoquinones in good to high yields. In addition, 2-azido-1,3-dimethylimidazolinium salts were employed as azide-transfer and migratory amidation reagents. © 2017 The Chemical Society of Japan & Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. 21 CFR 866.3550 - Salmonella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3550 Salmonella... isolates derived from clinical specimens. Additionally, some of these reagents consist of antisera... clinical specimens or cultured isolates derived from clinical specimens. The identification aids in the...

  10. International reference reagents: antihuman globulin. An ISBT/ICSH joint working party report. International Society of Blood Transfusion. International Committee for Standardization in Haematology.

    Science.gov (United States)

    Case, J; Ford, D S; Chung, A; Collins, R; Kochman, S; Mazda, T; Overbeeke, M; Perera, R; Sakuldamrongpanich, T; Scott, M; Voak, D; Zupańska, B

    1999-01-01

    An international working party has conducted a study designed to select a suitable reference reagent for antihuman globulin, to replace those first made available in 1987. The chosen preparation contains levels of anti-IgG and anti-C3 (anti-C3c and anti-C3d) potency that are considered suitable to serve for reference when evaluating either polyspecific antihuman globulin reagents or those containing their separate monospecific components. The reference material is available in 2-ml freeze-dried aliquots from seven assigned distribution centres.

  11. 21 CFR 866.3355 - Listeria spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3355 Listeria spp... from clinical specimens. Additionally, some of these reagents consist of Listeria spp. antisera... clinical specimens. The identification aids in the diagnosis of listeriosis, a disease caused by bacteria...

  12. IN-PLACE REGENERATION OF GAC USING FENTON'S REAGENTS

    Science.gov (United States)

    This paper evaluates the feasibility of using Fenton’s reagents for in-place recovery of spent granular activated carbon (GAC). Fenton’s reagents are cycled through spent GAC to degrade sorbed chlorinated hydrocarbons with little loss of carbon capacity. Seven chlorinated compou...

  13. Application of cyanuric chloride-based six new chiral derivatizing reagents having amino acids and amino acid amides as chiral auxiliaries for enantioresolution of proteinogenic amino acids by reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Bhushan, Ravi; Dixit, Shuchi

    2012-04-01

    Six dichloro-s-triazine (DCT) reagents having L-Leu, D-Phg, L-Val, L-Met, L-Ala and L-Met-NH(2) as chiral auxiliaries in cyanuric chloride were introduced for enantioseparation of 13 proteinogenic amino acids. Four other DCTs and six monochloro-s-triazine (MCT) reagents having amino acid amides as chiral auxiliaries were also synthesized. These 16 chiral derivatizing reagents (CDRs) were used for synthesis of diastereomers of all the 13 analytes using microwave irradiation, which were resolved by reversed-phase high-performance liquid chromatography (RP-HPLC) using C18 column and gradient eluting mixture of aqueous TFA and acetonitrile with UV detection at 230 nm. It required only 60-90 s for derivatization using microwave irradiation. Better resolution and lower retention times were observed for the diastereomers prepared with CDRs having amino acids as chiral auxiliaries as compared to counterparts prepared with reagents having amino acid amides as chiral auxiliaries. As the best resolution of all the 13 analytes was observed for their diastereomers prepared using the DCT reagent having L-Leu as chiral auxiliary, this CDR was further employed for derivatization of Lys, Tyr, His and Arg followed by RP-HPLC analysis of resulting diastereomers. The results are discussed in light of acid and amide groups of chiral auxiliaries constituting CDRs, electronegativities of the atoms of achiral moieties constituting CDRs and hydrophobicities of side chains of amino acids constituting CDRs and analytes.

  14. Reversed-phase liquid chromatography coupled on-line with capillary gas chromatography use of an anion-exchange membrane to remove an ion-pair reagent from the eluent.

    NARCIS (Netherlands)

    Brinkman, U.A.T.; Goosens, E.C.; de Jong, D.; de Jong, G.J.; Beerthuizen, I.M.

    1995-01-01

    In order to enable the coupling of reversed-phase liquid chromatography (RPLC) with capillary gas chromatography (GC), the performance of an anion-exchange micromembrane device has been studied to remove the ion-pair reagent methanesulphonic acid from an acetonitrile/water LC eluent. The regenerant

  15. New sorption-reagent materials for decontamination of liquid radioactive waste

    International Nuclear Information System (INIS)

    Avramenko, V.A.; Golikov, A.P.; Zheleznov, V.V.; Kaplun, E.V.; Marinin, D.V.; Sokolnitskaya, T.A.

    2001-01-01

    Full text: Use of selective sorbents in liquid radioactive waste (LRW) management is widely spread in the field of nuclear power objects liquid waste decontamination, since the main objective there is to remove long-lived radionuclides of the nuclear cycle. The latter include, first of all, cesium-137, strontium-90, cobalt-60 and a number of α-irradiators. In this case LRW composition for most of the nuclear power objects is rather simple, except acidic deactivation solutions. At the same time, liquid radioactive wastes of different research centers have a variable chemical and radiochemical composition depending on objectives and tasks of a given center research activities. As a result, application of sorption technologies in such waste decontamination determines special requirements to these sorbents selectivity: a wide spectrum of radionuclides that can be removed and fairly high selectivity enabling to remove radionuclides from solutions of complex chemical composition (containing surfactants, complexing agents etc.). This paper is concerned with studying properties of new materials selective to different radionuclides. These materials are capable to interact with solution components whether already contained in the waste or deliberately added into resulting solution. Such sorption-reagent materials combine universal character of co-precipitation methods with simplicity of sorption methods. In this work we studied sorption-reagent inorganic ion-exchange materials interacting with sulfate-, carbonate-, oxalate-, sulfide-, and permanganate-ions. Insoluble compounds formed as a result of this interaction increase tens- and hundreds-fold the sorption selectivity of different radionuclides - strontium, cobalt, mercury, iron, and manganese as compared to conventional ion-exchange system. By means of X-ray phase analysis, IR-spectroscopy, chemical and radiochemical analysis, we have studied the mechanism of radionuclide sorption on different sorption-reagent

  16. Tooth preparations for complete crowns: an art form based on scientific principles.

    Science.gov (United States)

    Goodacre, C J; Campagni, W V; Aquilino, S A

    2001-04-01

    No recent literature has reviewed the current scientific knowledge on complete coverage tooth preparations. This article traces the historic evolution of complete coverage tooth preparations and identifies guidelines for scientific tooth preparations. Literature covering 250 years of clinical practice was reviewed with emphasis on scientific data acquired during the last 50 years. Both a MEDLINE search and an extensive manual search were used to locate relevant articles written in English in the last 50 years. Teeth should be prepared so that they exhibit the following characteristics: 10 to 20 degrees of total occlusal convergence, a minimal occlusocervical dimension of 4 mm for molars and 3 mm for other teeth, and an occlusocervical-to-faciolingual dimension ratio of 0.4 or greater. Facioproximal and linguoproximal line angles should be preserved whenever possible. When the above features are missing, the teeth should be modified with auxiliary resistance features such as axial grooves or boxes, preferably on proximal surfaces. Finish line selection should be based on the type of crown/retainer, esthetic requirements, ease of formation, and personal experience. Expectations of enhanced marginal fit with certain finish lines could not be validated by recent research. Esthetic requirements and tooth conditions determine finish line locations relative to the gingiva, with a supragingival location being more acceptable. Line angles should be rounded, and a reasonable degree of surface smoothness is desired. Nine scientific principles have been developed that ensure mechanical, biologic, and esthetic success for tooth preparation of complete coverage restorations.

  17. Preparation of PbSe nanoparticles by electron beam irradiation

    Indian Academy of Sciences (India)

    A novel method has been developed by electron beam irradiation to prepare PbSe nanoparticles. 2 MeV 10mA GJ-2-II electronic accelerator was used as radiation source. Nanocrystalline PbSe was prepared rapidly at room temperature under atmospheric pressure without any kind of toxic reagents. The structure and ...

  18. Noninfectious virus-like particles produced by Moloney murine leukemia virus-based retrovirus packaging cells deficient in viral envelope become infectious in the presence of lipofection reagents

    Science.gov (United States)

    Sharma, Sanjai; Murai, Fukashi; Miyanohara, Atsushi; Friedmann, Theodore

    1997-01-01

    Retrovirus packaging cell lines expressing the Moloney murine leukemia virus gag and pol genes but lacking virus envelope genes produce virus-like particles constitutively, whether or not they express a transcript from an integrated retroviral provirus. In the absence of a proviral transcript, the assembled particles contain processed gag and reverse transcriptase, and particles made by cells expressing an integrated lacZ provirus also contain viral RNA. The virus-like particles from both cell types are enveloped and are secreted/budded into the extracellular space but are noninfectious. Their physicochemical properties are similar to those of mature retroviral particles. The noninfectious gag pol RNA particles can readily be made infectious by the addition of lipofection reagents to produce preparations with titers of up to 105 colony-forming units per ml. PMID:9380714

  19. Noninfectious virus-like particles produced by Moloney murine leukemia virus-based retrovirus packaging cells deficient in viral envelope become infectious in the presence of lipofection reagents.

    Science.gov (United States)

    Sharma, S; Murai, F; Miyanohara, A; Friedmann, T

    1997-09-30

    Retrovirus packaging cell lines expressing the Moloney murine leukemia virus gag and pol genes but lacking virus envelope genes produce virus-like particles constitutively, whether or not they express a transcript from an integrated retroviral provirus. In the absence of a proviral transcript, the assembled particles contain processed gag and reverse transcriptase, and particles made by cells expressing an integrated lacZ provirus also contain viral RNA. The virus-like particles from both cell types are enveloped and are secreted/budded into the extracellular space but are noninfectious. Their physicochemical properties are similar to those of mature retroviral particles. The noninfectious gag pol RNA particles can readily be made infectious by the addition of lipofection reagents to produce preparations with titers of up to 10(5) colony-forming units per ml.

  20. Statistical validation of reagent lot change in the clinical chemistry laboratory can confer insights on good clinical laboratory practice.

    Science.gov (United States)

    Cho, Min-Chul; Kim, So Young; Jeong, Tae-Dong; Lee, Woochang; Chun, Sail; Min, Won-Ki

    2014-11-01

    Verification of new lot reagent's suitability is necessary to ensure that results for patients' samples are consistent before and after reagent lot changes. A typical procedure is to measure results of some patients' samples along with quality control (QC) materials. In this study, the results of patients' samples and QC materials in reagent lot changes were analysed. In addition, the opinion regarding QC target range adjustment along with reagent lot changes was proposed. Patients' sample and QC material results of 360 reagent lot change events involving 61 analytes and eight instrument platforms were analysed. The between-lot differences for the patients' samples (ΔP) and the QC materials (ΔQC) were tested by Mann-Whitney U tests. The size of the between-lot differences in the QC data was calculated as multiples of standard deviation (SD). The ΔP and ΔQC values only differed significantly in 7.8% of the reagent lot change events. This frequency was not affected by the assay principle or the QC material source. One SD was proposed for the cutoff for maintaining pre-existing target range after reagent lot change. While non-commutable QC material results were infrequent in the present study, our data confirmed that QC materials have limited usefulness when assessing new reagent lots. Also a 1 SD standard for establishing a new QC target range after reagent lot change event was proposed. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  1. Systematic trends in photonic reagent induced reactions in a homologous chemical family.

    Science.gov (United States)

    Tibbetts, Katharine Moore; Xing, Xi; Rabitz, Herschel

    2013-08-29

    The growing use of ultrafast laser pulses to induce chemical reactions prompts consideration of these pulses as "photonic reagents" in analogy to chemical reagents. This work explores the prospect that photonic reagents may affect systematic trends in dissociative ionization reactions of a homologous family of halomethanes, much as systematic outcomes are often observed for reactions between homologous families of chemical reagents and chemical substrates. The experiments in this work with photonic reagents of varying pulse energy and linear spectral chirp reveal systematic correlations between observable ion yields and the following set of natural variables describing the substrate molecules: the ionization energy of the parent molecule, the appearance energy of each fragment ion, and the relative strength of carbon-halogen bonds in molecules containing two different halogens. The results suggest that reactions induced by photonic reagents exhibit systematic behavior analogous to that observed in reactions driven by chemical reagents, which provides a basis to consider empirical "rules" for predicting the outcomes of photonic reagent induced reactions.

  2. APPLICATION OF FENTON’S REAGENT ON REMEDIATION OF POLYCYCLIC AROMATIC HYDROCARBONs (PAHs IN SPIKED SOIL

    Directory of Open Access Journals (Sweden)

    Nursiah La Nafie

    2010-06-01

    Full Text Available Problem associated with Polycyclic Aromatic Hydrocarbons (PAHs contaminated site in environmental media have received increasing attention. To resolve such problems, innovative in situ methods are urgently required. This work investigated the feasibility of using Fenton's Reagent to remediate PAHs in spiked soil. PAHs were spiked into soil to simulate contaminated soil. Fenton's Reagent (H2O2 + Fe2+ and surfactant were very efficient in destruction of PAHs including naphthalene, anthracene, fluoranthene, pyrene, and benzo(apyrene from spiked soil. It was indicated by the fact that more than 96% of PAHs were degraded in the solution and the spiked soil.   Keywords: Environmental, Fenton's Reagent, Polycyclic Aromatic Hydrocarbons, and Spiked soil.

  3. Organic-soluble lanthanide nuclear magnetic resonance shift reagents for sulfonium and isothiouronium salts

    International Nuclear Information System (INIS)

    Wenzel, T.J.; Zaia, J.

    1987-01-01

    Lanthanide complexes of the formula [Ln(fod) 4 ] - (FOD, 6,6,7,7,8,8,8-heptafluoro-2,2-dimethyl-3,5-octanedione) are effective organic-soluble nuclear magnetic resonance shift reagents for sulfonium and isothiouronium salts. The shift reagent is formed in solution from Ln(fod) 3 and Ag(fod) or K(fod). The selection of Ag(fod) or K(fod) in forming the shift reagent is dependent on the anion of the organic salt. Ag(fod) is more effective with halide salts, whereas K(fod) is preferred with tetrafluoroborate salts. Resolution of diastereotopic hydrogen atoms was observed in the shifted spectra of certain substrates. Enantiomeric resolution was obtained in the spectrum of sec-butylisothiouronium chloride with a chiral shift reagent. The reagents can be employed in solvents such as chloroform and benzene

  4. 77 FR 32626 - Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Impact...

    Science.gov (United States)

    2012-06-01

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PF09-8-000] Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Impact Statement for the Planned Rockaway Delivery Lateral Project, Request for Comments on Environmental Issues, and Notice of Public Scoping Meetings The staff of the Federa...

  5. 21 CFR 864.8950 - Russell viper venom reagent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Russell viper venom reagent. 864.8950 Section 864.8950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8950 Russell viper venom...

  6. Miniature stick-packaging--an industrial technology for pre-storage and release of reagents in lab-on-a-chip systems.

    Science.gov (United States)

    van Oordt, Thomas; Barb, Yannick; Smetana, Jan; Zengerle, Roland; von Stetten, Felix

    2013-08-07

    Stick-packaging of goods in tubular-shaped composite-foil pouches has become a popular technology for food and drug packaging. We miniaturized stick-packaging for use in lab-on-a-chip (LOAC) systems to pre-store and on-demand release the liquid and dry reagents in a volume range of 80-500 μl. An integrated frangible seal enables the pressure-controlled release of reagents and simplifies the layout of LOAC systems, thereby making the package a functional microfluidic release unit. The frangible seal is adjusted to defined burst pressures ranging from 20 to 140 kPa. The applied ultrasonic welding process allows the packaging of temperature sensitive reagents. Stick-packs have been successfully tested applying recovery tests (where 99% (STDV = 1%) of 250 μl pre-stored liquid is released), long-term storage tests (where there is loss of only <0.5% for simulated 2 years) and air transport simulation tests. The developed technology enables the storage of a combination of liquid and dry reagents. It is a scalable technology suitable for rapid prototyping and low-cost mass production.

  7. An oral Mycobacterium bovis BCG vaccine for wildlife produced in the absence of animal-derived reagents.

    Science.gov (United States)

    Cross, Martin L; Lambeth, Matthew R; Aldwell, Frank E

    2009-09-01

    Cultures of Mycobacterium bovis BCG, comprising predominantly single-cell bacilli, were prepared in broth without animal-derived reagents. When formulated into a vegetable-derived lipid matrix, the vaccine was stable in vitro and was immunogenic in vivo upon feeding it to mice. This formulation could be useful for oral vaccination of wildlife against tuberculosis, where concern over transmissible prions may preclude the field use of vaccines containing animal products.

  8. In-capillary determination of creatinine with electrophoretically mediated microanalysis: characterization of the effects of reagent zone and buffer conditions.

    Science.gov (United States)

    Mason, Philip E; Schildt, Derek C; Strein, Timothy G

    2009-01-02

    Previous work has demonstrated proof-of-concept for carrying out the clinically useful Jaffe reaction between creatinine and picrate within a capillary tube using electrophoretically mediated microanalysis (EMMA). Here, it is shown that careful control of reagent plug length as well as concentration and pH of the background electrolyte (BGE) can result in a marked improvement in the sensitivity of this assay. Increasing the length of the picrate reagent zone is shown to give rise to as much as a 3-4-fold enhancement, and increasing the concentration and/or pH of the borate buffer also results in an additional, albeit modest, improvement in sensitivity. Interestingly, borate BGE concentrations approaching 100mM give rise to an unexplained drop in reaction efficiency, an effect which can be avoided by utilizing lower borate concentration with higher pH. The improvements appear to primarily minimize electrodispersion of the picrate reagent, allowing higher picrate concentration in the reaction zone. The same conditions also appear to minimize the electrodispersion of the in-line product as well. With optimized EMMA parameters, the sensitivity of the in-line Jaffe chemistry can be enhanced to an extent that there is no need for the two capillary "high sensitivity" detection system required in previous work. Using optimized conditions, three different human serum samples spanning the expected clinical range of creatinine concentrations were successfully analyzed. Overall, this work illustrates the importance of systematically characterizing the conditions under which EMMA analyses are carried out.

  9. Diagnóstico das meningites através de fitas reagentes Diagnosis of meningitis with reagent strips

    Directory of Open Access Journals (Sweden)

    Roberta M.C. Romanelli

    2001-06-01

    Full Text Available OBJETIVO: determinar a utilidade de fitas reagentes para a avaliação liquórica de pleocitose, glicorraquia e proteinorraquia no diagnóstico precoce e rápido de meningites em crianças. MÉTODOS: Foram incluídas no estudo amostras de líquor provenientes de 164 crianças admitidas no ambulatório de doenças infecto-contagiosas do Centro Geral de Pediatria (CGP-FHEMIG, com suspeita clínica de meningite, no período diurno de Maio/97 à Maio/99. A faixa etária dos pacientes variou de um mês a 12 anos (mediana de 12 meses, sendo obtidos resultados da citobioquímica liquórica (celularidade, glicorraquia e proteinorraquia de 154 desses pacientes. Esses achados foram comparados com reações do líquor em fitas reagentes. RESULTADOS: Através da citobioquímica líquórica foram identificados 43 casos de provável meningite bacteriana, 19 provavelmente viróticas e 83 amostras sem alterações. Pelas fitas reagentes, detectaram-se 41 casos de provável meningite bacteriana, dois casos de infecção meníngea provavelmente virótica, e em 71 exames não se verificaram alterações. Comparando os resultados obtidos por meio das fitas reagentes com a citobioquímica convencional, observou-se sensibilidade, especificidade, valores preditivos positivo e negativo e acurácia (90,7; 98,1; 95,1; 96,4; 96,1%, respectivamente. Ademais, a análise estatística pelo teste de Mc Nemar não evidenciou discordância significativa no diagnóstico de meningite bacteriana obtido através de ambos os métodos (p=0,68 e, pela estatística Kappa, verificou-se elevado grau de concordância entre os testes (pOBJECTIVE: to determine the usefulness of reagent strips in the evaluation of pleocytosis, cerebrospinal fluid glucose and protein levels for early and rapid diagnosis of meningitis in children. METHODS: We included cerebrospinal fluid samples of 164 children admitted to the outpatient clinic of Communicable Diseases of the General Pediatric Center (Funda

  10. On-line digestion in a focused microwave-assisted oven for elements determination in orange juice by inductively coupled plasma optical emission spectrometry

    Directory of Open Access Journals (Sweden)

    Fili Sabrina P.

    2003-01-01

    Full Text Available A flow injection system coupled to focused microwave-assisted oven was used for on-line orange juice sample digestion for determination of Ca, Cu, Fe, K, Mg, Mn, Na, P, and Zn by inductively coupled plasma optical emission spectrometry. The reactor coil was a PTFE tube (4.0 m long and 1.6 mm i.d. positioned into the commercial glass tube of the focused microwave oven. Aliquots of 500 muL of sample and 1000 muL of reagent (80% v/v HNO3 were mixed in a confluence and carried out to the reactor coil by air carrier. The relative standard deviation for five replicates of sample was lower than 5.0%. Good recoveries varying from 91 to 111% were obtained for added concentrations of the interest elements. The results obtained using the proposed digestion system are in agreement with those obtained for total digestion at the 95% confidence level. With this on-line digestion system was possible to carry out 12 samples h-1, minimizing contamination, saving consumption of samples and reagent and low residue generation.

  11. 78 FR 78350 - Houston Pipe Line Company, LP; Notice of Intent to Prepare an Environmental Assessment for the...

    Science.gov (United States)

    2013-12-26

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP14-13-000] Houston Pipe Line Company, LP; Notice of Intent to Prepare an Environmental Assessment for the Proposed 24-Inch... Hidalgo County, Texas by Houston Pipe Line Company, LP (HPL). The Commission will use this EA in its...

  12. Effects of reagent translational and vibrational energy on the dynamics of endothermic reactions

    Energy Technology Data Exchange (ETDEWEB)

    Krajnovich, D.; Zhang, Z.; Huisken, F.; Shen, Y.R.; Lee, Y.T.

    1981-07-01

    The endothermic reactions Br + CH/sub 3/I ..-->.. CH/sub 3/ + IBr (..delta..H/sub 0//sup 0/ = 13 kcal/mole) and Br + CF/sub 3/I ..-->.. CF/sub 3/ + IBr (..delta..H/sub 0//sup 0/ = 11 kcal/mole) have been studied by the crossed molecular beams method. Detailed center-of-mass contour maps of the IBr product flux as a function of recoil velocity and scattering angle are derived. For both systems it is found that the IBr product is sharply backward scattered with respect to the incident Br dirction, and that most of the available energy goes into product translation. Vibrational enhancement of the Br + CF/sub 3/I reaction was investigated by using the infrared multiphoton absorption process to prepare highly vibrationally excited CF/sub 3/I. At a collision energy of 31 kcal/mole (several times the barrier height), reagent vibrational energy appears to be less effective than an equivalent amount of (additional) translational energy in promoting reaction. More forward scattered IBr is produced in reactions of Br with vibrationally hot CF/sub 3/I.

  13. Effects of reagent translational and vibrational energy on the dynamics of endothermic reactions

    International Nuclear Information System (INIS)

    Krajnovich, D.; Zhang, Z.; Huisken, F.; Shen, Y.R.; Lee, Y.T.

    1981-07-01

    The endothermic reactions Br + CH 3 I → CH 3 + IBr (ΔH 0 0 = 13 kcal/mole) and Br + CF 3 I → CF 3 + IBr (ΔH 0 0 = 11 kcal/mole) have been studied by the crossed molecular beams method. Detailed center-of-mass contour maps of the IBr product flux as a function of recoil velocity and scattering angle are derived. For both systems it is found that the IBr product is sharply backward scattered with respect to the incident Br dirction, and that most of the available energy goes into product translation. Vibrational enhancement of the Br + CF 3 I reaction was investigated by using the infrared multiphoton absorption process to prepare highly vibrationally excited CF 3 I. At a collision energy of 31 kcal/mole (several times the barrier height), reagent vibrational energy appears to be less effective than an equivalent amount of (additional) translational energy in promoting reaction. More forward scattered IBr is produced in reactions of Br with vibrationally hot CF 3 I

  14. Decolorizing textile wastewater with Fenton's reagent electrogenerated with a solar photovoltaic cell.

    Science.gov (United States)

    Figueroa, Sandra; Vázquez, Leticia; Alvarez-Gallegos, A

    2009-02-01

    In this work it is demonstrated that Fenton's reagent can be electroproduced with abundant and cheap feedstock: oxygen saturated wastewater and solar energy. Experiments were carried out in a divided electrochemical flow cell using two electrodes: a three dimensional reticulated vitreous carbon cathode and stainless steel anode. Fenton's reagent is produced by oxygen reduction on the cathode in the presence of 1mM Fe(2+). The influence of electrolyte nature and its concentration and potential difference on the current efficiency, as well as the rate of Fenton's reagent electroproduction is discussed and it is concluded that over this extended range of conditions the current efficiency, for Fenton's reagent production, fell within the range 50-70%. It is possible to electroproduce a stoichiometric amount of Fenton reagent for the oxidation of 0.061mM Reactive Black 5 (in tap water+0.05M Na(2)SO(4), approximately pH 2.8). Similar results were obtained for solutions containing 0.1mM Acid Green 25. Some practical applications in the field of water treatment are included. The energy required for drive electrochemical reaction is supplied to the flow cell by means of a commercial solar panel.

  15. Studies on synthesis of a kind of new colour reagents bromophosphonobisazo derivatives of chromotropic acid and the effect of their constitution on colour behaviours with rare earth elements

    International Nuclear Information System (INIS)

    Bincai, W.; Yuxin, Q.; Hengchuan, L.

    1985-01-01

    Based on the previous systematic studies, this paper reports to the original constitution of chlorophosphonazo type of colour reagents, has been reformed, and a kind of 14 new asymmetrical bromophosphonobisazo colour reagents of chromotropic acid have been designed and synthesized. In the meanwhile, the relationship between constitution of colour reagents and its behaviour in colour reaction with rare earth elements has been investigated. In addition, the general colour behaviours of these reagents and the influence of organic solvents and surfactants have been preliminarily studied

  16. Validity of HydraTrend reagent strips for the assessment of hydration status.

    Science.gov (United States)

    Abbey, Bryce M; Heelan, Kate A; Brown, Gregory A; Bartee, Rodrick T

    2014-09-01

    Hydration is used by athletic governing organizations for weight class eligibility. The measurement of urine specific gravity (USG) as a measure of hydration by reagent strips is a controversial issue. The purpose of this study was to determine the validity of HydraTrend reagent strips that facilitate the correction of USG for alkaline urine samples against refractometry for the assessment of USG. Fifty-one participants (33 males, age = 22.3 ± 1.3 years; 18 females, age = 22.4 ± 1.2 years) provided 84 urine samples. The samples were tested for USG using refractometry and reagent strips and for pH using reagent strips and a digital pH meter. Strong correlation coefficients were found between refractometry and reagent strips for USG (rs(82) = 0.812, p refractometry with USG >1.020, pass reagent strips with USG ≤1.020) occurred 39% (33/84) of the time and false negative results for National Federation of State High School Association (NFHS) requirements (fail refractometry with USG >1.025, pass reagent strips with USG ≤1.025) occurred 14% (12/84) of the time. There were no false positives (pass refractometry and fail reagent strips) for NCAA or NFHS requirements. These data show that refractometry and reagent strips have strong positive correlations. However, the risk of a false negative result leading to incorrect certification of euhydration status outweighs the benefits of the HydraTrend reagent strips for the measurement of USG.

  17. Capillary electrophoresis microchip coupled with on-line chemiluminescence detection

    International Nuclear Information System (INIS)

    Su Rongguo; Lin Jinming; Qu Feng; Chen Zhifeng; Gao Yunhua; Yamada, Masaaki

    2004-01-01

    In the present work, chemiluminescence detection was integrated with capillary electrophoresis microchip. The microchip was designed on the principle of flow-injection chemiluminescence system and capillary electrophoresis. It has three main channels, five reservoirs and a detection cell. As model samples, dopamine and catechol were separated and detected using a permanganate chemiluminescent system on the prepared microchip. The samples were electrokinetically injected into the double-T cross section, separated in the separation channel, and then oxidized by chemiluminescent reagent delivered by a home-made micropump to produce light in the detection cell. The electroosmotic flow could be smoothly coupled with the micropump flow. The detection limits for dopamine and catechol were 20.0 and 10.0 μM, respectively. Successful separation and detection of dopamine and catechol demonstrated the distinct advantages of integration of chemiluminescent detection on a microchip for rapid and sensitive analysis

  18. Influence of Fenton's reagent treatment on electrochemical properties of graphite felt for all vanadium redox flow battery

    International Nuclear Information System (INIS)

    Gao, Chao; Wang, NanFang; Peng, Sui; Liu, SuQin; Lei, Ying; Liang, XinXing; Zeng, ShanShan; Zi, HuiFang

    2013-01-01

    Highlights: ► Highly hydroxyl-functionalized graphite felt has been obtained through Fenton's reagent treatment. ► Fenton's reagent treatment involves only one step, works under ambient conditions and will never produce any toxic gas. ► The treated graphite felt exhibits superior electrochemical performance in comparison to the untreated one. -- Abstract: An environmental, economic and highly effective method for carbon fiber hydroxylated-functionalization based on Fenton's reagent treatment is used to improve the electrochemical activity of graphite felt (GF) as the positive electrode in all vanadium redox flow battery (VRFB). The effect of H 2 O 2 content in Fenton's reagent on the structure and electrochemical properties of GF is investigated. The scanning electron microscope (SEM) indicates that the surface of the treated GF is etched increasingly with the content of H 2 O 2 . The Fourier transformation infrared (FTIR) spectroscopy shows that the peak intensity of hydroxyl groups on the treated felt is increased with the H 2 O 2 concentration, which is further verified by X-ray photoelectron spectroscopy (XPS). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) show that the treated sample exhibits a higher electrochemical activity. A VRFB with the treated GF as electrodes exhibits higher coulombic, voltage and energy efficiency (98.8%, 75.1% and 74.2%) than that with the untreated GF (93.9%, 72.1% and 67.7%) at 60 mA cm −2 , and this method is even superior when compared with the reported methods

  19. Short communication: Adverse effect of surface-active reagents on the bioleaching of pyrite and chalcopyrite by Thiobacillus ferrooxidans.

    Science.gov (United States)

    Huerta, G; Escobar, B; Rubio, J; Badilla-Ohlbaum, R

    1995-09-01

    Oxidation of Fe(II) iron and bioleaching of pyrite and chalcopyrite by Thiobacillus ferrooxidans was adversely affected by isopropylxanthate, a flotation agent, and by LIX 984, a solvent-extraction agent, each at ≤ 1 g/l. The reagents/l were adsorbed on the bacterial surface, decreasing the bacteria's development and preventing biooxidation. Both reagents inhibited the bioleaching of pyrite and LIX 984 also inhibited the bioleaching of chalcopyrite.

  20. Study of effect of slime processed by ultrasonic on flotation reagent

    Energy Technology Data Exchange (ETDEWEB)

    Kang, W.; Wang, H.; Hu, J. [Heilongjiang Institute of Science and Technology, Harbin (China)

    2006-12-15

    The changes of wetting heat, oil film thickness, contact angle and absorptive capacity of slime and kerosene before and after ultrasonic treatment were studied by Setaram calorimeter, DCAT21 gauge and a light meter. Batch flotation tests were made. The results show that: the wetting heat from slime and kerosene increases after ultrasonic treatment by 45.85%; the average oil film thickness is reduced by 38.84%; the contact angle of slime and kerosene decreases by 33.56{sup o}; and the absorptive capacity of slime in kerosene decreases by 30.40%. The consumption of flotation reagent after ultrasonic treatment was reduced by 75% while the yield of clean coal was the same. The study shows that ultrasonic treatment decreases the consumption of reagent and increases the efficiency and selectivity of flotation. 8 refs., 3 figs., 4 tabs.

  1. Lanthanide shift reagents, binding, shift mechanisms and exchange

    International Nuclear Information System (INIS)

    Boer, J.W.M. de

    1977-01-01

    Paramagnetic lanthanide shift reagents, when added to a solution of a substrate, induce shifts in the nuclear magnetic resonance (NMR) spectrum of the substrate molecules. The induced shifts contain information about the structure of the shift reagent substrate complex. The structural information, however, may be difficult to extract because of the following effects: (1) different complexes between shift reagent and substrate may be present in solution, e.g. 1:1 and 1:2 complexes, and the shift observed is a weighed average of the shifts of the substrate nuclei in the different complexes; (2) the Fermi contact interaction, arising from the spin density at the nucleus, contributes to the induced shift; (3) chemical exchange effects may complicate the NMR spectrum. In this thesis, the results of an investigation into the influence of these effects on the NMR spectra of solutions containing a substrate and LSR are presented. The equations describing the pseudo contact and the Fermi contact shift are derived. In addition, it is shown how the modified Bloch equations describing the effect of the chemical exchange processes occurring in the systems studied can be reduced to the familiar equations for a two-site exchange case. The binding of mono- and bifunctional ethers to the shift reagent are reported. An analysis of the induced shifts is given. Finally, the results of the experiments performed to study the exchange behavior of dimethoxyethane and heptafluorodimethyloctanedionato ligands are presented

  2. Reagent and process for detaching furfural in petroleum products

    Energy Technology Data Exchange (ETDEWEB)

    Orelup, R.B.

    1987-07-14

    A two-component liquid reagent and process is provided for detecting the presence of furfural in petroleum products. The reagent comprises two components which are stored separately from each other and are combined prior to admixture with the petroleum product. The process comprises combining the two separate components of the liquid reagent with each other prior to use, admixing the combined components with a petroleum product containing furfural, shaking the resultant mixture, allowing the mixture to separate and observing a red color characteristic of furfural in the lower layer. Alternately, the process may be carried out by combining the second component of the two-component liquid reagent with the petroleum product, followed by admixture with the first component to obtain two separate layers in which the red color characteristic of furfural is observed in the lower layer.

  3. Interfacial reaction using particle-immobilized reagents in a fluidized reactor. Determination of glycerol in biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Shishov, Andrey, E-mail: andrey.shishov.rus@gmail.com [Institute of Chemistry, Saint Petersburg State University, RU–198504 Saint Petersburg (Russian Federation); Zabrodin, Andrey; Moskvin, Leonid [Institute of Chemistry, Saint Petersburg State University, RU–198504 Saint Petersburg (Russian Federation); Andruch, Vasil [Department of Analytical Chemistry, University of P.J. Šafárik, SK-04154 Košice (Slovakia); Bulatov, Andrey [Institute of Chemistry, Saint Petersburg State University, RU–198504 Saint Petersburg (Russian Federation)

    2016-03-31

    A novel fluidized beads strategy for utilization of particle-immobilized reagents in flow analysis was developed in this study. The performance of the suggested strategy was demonstrated by the determination of glycerol in biodiesel. This analytical task was used as a proof-of-concept example. The method is based on on-line extraction of glycerol from biodiesel into aqueous stationary phase of extraction-chromatographic column, followed by elution and spectrophotometric determination in the form of copper glycerate formed in a fluidized reactor of stepwise injection system. The floating of cation exchange resin Dowex{sup ®} 50WX4, saturated with Cu(II) ions in liquid phase, was accomplished by air-bubbling. The linear range was from 100 to 1000 mg kg{sup −1}, and the limit of detection, calculated as 3s of a blank test (n = 5), was found to be 30 mg kg{sup −1}. The method was successfully applied to the analysis of biodiesel and biodiesel-blend (B 20) samples. - Highlights: • Novel fluidized beds strategy for utilization of particle-immobilized reagents. • First application of fluidized beds condition in SWIA. • Novel approach based on interfacial formation of copper glycerate. • Automated method for glycerol determination in biodiesel.

  4. The reaction of organocerium reagents with easily enolizable ketones

    International Nuclear Information System (INIS)

    Imamoto, Tsuneo; Kusumoto, Tetsuo; Sugiura, Yasushi; Suzuki, Nobuyo; Takiyama, Nobuyuki

    1985-01-01

    Organocerium (III) reagents were conveniently generated by the reaction of organolithium compounds with anhydrous cerium (III) chloride. The reagents are less basic than organolithiums and Grignard reagents, and they react readily at -78 deg C with easily enolizable ketones such as 2-tetralone to afford addition products in high yields. Cerium (III) enolates were also generated from lithium enolates and cerium (III) chloride. The cerium (III) enolates undergo aldol addition with ketones or sterically crowded aldehyde to give the corresponding β-hydroxy ketones in good to high yields. (author)

  5. Plutonium metal preparation and purification at Los Alamos, 1984

    International Nuclear Information System (INIS)

    Christensen, D.C.; Williams, J.D.; McNeese, J.A.; Fife, K.W.

    1984-01-01

    Plutonium metal preparation and purification are well established at Los Alamos. Metal is prepared by calcothermic reduction of both PuF 4 and PuO 2 . Metal is purified by halide slagging, casting, and electrorefining. The product from the production sequence is ultrapure plutonium metal. All of the processes involve high temperature operation and all but casting involve molten salt media. Development efforts are fourfold: (1) recover plutonium values from residues; (2) reduce residue generation through process improvements and changes; (3) recycle of reagents, and (4) optimize and integrate all processes into a close-loop system. Plutonium residues are comprised of oxides, chlorides, colloidal metal suspensions, and impure metal heels. Pyrochemical recovery techniques are under development to address each residue. In addition, we are looking back at each residue generation step and are making process changes to reduce plutonium content in each residue. Reagent salt is the principle media used in pyrochemical processing. The regeneration and recycle of these reagents will both reduce our waste handling and operating expense. The fourth area, process optimization, involves both existing processes and new process developments. A status of efforts in all four of these areas will be summarized

  6. Reagent for treating clay drilling muds

    Energy Technology Data Exchange (ETDEWEB)

    Tkachenko, P V; Leshchinskiy, P A; Shnaper, B I; Zinchuk, I F; Zlobin, V P

    1982-01-01

    A reagent is proposed for treating clay drilling muds. It contains lignite, caustic soda and modifying agent. It is distinguished by the fact that in order to reduce the cost of the reagent with simultaneous decrease in the viscosity and static shear stress of the drilling mud, it additionally contains iron sulfate, and the modifying agent contained is wastes of carbonic acid production with the following ratio of components (parts by weight): lignite 10.0-15.0, caustic soda 2.0-3.0, wastes of carbonic acid production 0.5-0.75; iron sulfate 1.0-2.0.

  7. Low Temperature Steam Methane Reforming Over Ni Based Catalytic Membrane Prepared by Electroless Palladium Plating.

    Science.gov (United States)

    Lee, Sang Moon; Hong, Sung Chang; Kim, Sung Su

    2018-09-01

    A Pd/Ni-YSZ porous membrane with different palladium loadings and hydrazine as a reducing reagent was prepared by electroless plating and evaluated for the steam methane reforming activity. The steam-reforming activity of a Ni-YSZ porous membrane was greatly increased by the deposition of 4 g/L palladium in the low-temperature range (600 °C). With an increasing amount of reducing reagent, the Pd clusters were well dispersed on the Ni-YSZ surface and were uniform in size (∼500 nm). The Pd/Ni-YSZ catalytic porous membrane prepared by 1 of Pd/hydrazine ratio possessed an abundant amount of metallic Pd. The optimal palladium loadings and Pd/hydrazine ratio increased the catalytic activity in both the steam-reforming reaction and the Pd dispersion.

  8. Effect of preparation conditions on properties and permeability of chitosan-sodium hexametaphosphate capsules.

    Science.gov (United States)

    Angelova, N; Hunkeler, D

    2001-01-01

    Capsules were obtained by interpolymer complexation between chitosan (polycation) and sodium hexametaphosphate (SMP, oligoanion). The effect of the preparation conditions on the capsule characteristics was evaluated. Specifically, the influence of variables such as pH, ionic strength, reagent concentration, and additives on the capsule permeability properties was investigated using dextran as a model permeant. The capsule membrane permeability was found to increase by decreasing the chitosan/SMP ratio as well as adding mannitol to the oligoanion recipient bath. Increasing the ionic strength or the pH of the initial chitosan solution was also found to enhance the membrane permeability, moving the membrane exclusion limit to higher values. Generally, the capsules prepared tinder all tested conditions had a relatively low permeability which rarely exceeded a molecular cut-off of 40 kD based on dextran standards. Furthermore, the diffusion rate showed a strong temporal dependence, indicating that the capsules prepared under various conditions exhibit different apparent pore size densities on the surface. The results indicated that, in order to obtain the desired capsule mass-transfer properties, the preparation conditions should be carefully considered and adjusted. Adding a polyol as well as low salt amount (less than 0.15%) is preferable as a means of modulating the diffusion characteristics, without disturbing the capsule mechanical stability.

  9. Effect of flotation on preparation of coal-water slurries

    Energy Technology Data Exchange (ETDEWEB)

    Ding, K.; Laskowski, J.S. [University of British Columbia, Vancouver, BC (Canada)

    2009-07-01

    In order to study the effect of flotation reagents on the properties of coal-water slurry, a sub-bituminous coal was cleaned via either forward flotation or reverse flotation. The froth product from the forward flotation, obtained with the use of diesel oil and MIBC, and the tailings of the reverse flotation, carried out with dextrin-tannic acid depressants and dodecyltrimethylammonium chloride collector, were used in the preparation of coal-water slurries. It was shown that while it was possible to obtain the coal-water slurry with a high-solids content from the coal rendered hydrophilic (tailings from the coal reverse flotation), in the case of the hydrophobic product (froth product from the forward flotation) a dispersing agent was required to obtain the coal-water slurry of the same high-solids content.

  10. Studies on local preparation of double antibody radioimmunoassay for determination of alpha fetoprotein as a tumor marker

    International Nuclear Information System (INIS)

    Elkolaly, M.T.; Mehany, N.L.; Ragab, M.T.; El-Mohty, A.A.

    2001-01-01

    The preparation of primary reagents of AFP- RIA technique with low cost is considered to be one of the main objective of labelled compounds Dept., Radioisotope production Division, Hot Labs Centre, Atomic Energy Authority, Egypt. The development of a radioimmunoassay system based on local production of basic reagents for the measurement of AFP in human serum is described. The assay followed by 100 μ1 of locally prepared 125 I-AFP to 100 μ1 standards and unknown samples. After overnight incubation at 4 degree, separating reagents were added in following sequence 100 μ1 non-immune rabbit serum (1:200) followed by addition of 100μ1 of donkey anti-rabbit serum, (1:20), then 500μ1 of 8 percentage polyethylene glycol (PEG) were added into all assay tubes. The tubes were allowed to stand for 30 minutes at room temperature and then centrifuged for 15 minutes. the tubes were decanted and counted in a gamma counter. The results of the present study showed that the assay is highly sensitive where the detection limit or minimal detectable dose of AFP assay approximately 1.5 I U/ml. The reliability of the present procedure was assessed by examining its reproducibility on pooled human serum samples selected to represent different levels of AFP. The data of intra-assay and intra-assay precision revealed the consistency of the results obtained by the method of the present study. The present technique for determination of serum AFP agreed well with commercially available kits (DPC, double antibody-diagnostic product corporation, los angeles, USA). The technical simplicity of this specific, accurate and reasonably precise method may suggest that the technique should be suited for routine laboratory use

  11. 21 CFR 866.3520 - Rubeola (measles) virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rubeola (measles) virus serological reagents. 866... Rubeola (measles) virus serological reagents. (a) Identification. Rubeola (measles) virus serological... to rubeola virus in serum. The identification aids in the diagnosis of measles and provides...

  12. Efficacy comparative of different laboratory test reagents for hepatitis C virus antibody

    Directory of Open Access Journals (Sweden)

    GUO Feibo

    2016-09-01

    Full Text Available Objective To investigate the effects of different laboratory test reagents for hepatitis C virus (HCV antibody through a comparative analysis. Methods A total of 207 samples which tested positive by four anti-HCV screening reagents commonly used in the laboratories in China (Kehua, Xinchuang, Wantai, and Abbott were included. HCV RNA nucleic acid amplification (NAT was performed, and if NAT results were negative, recombinant immunoblot assay (RIBA was performed for further confirmation. The test results of these four screening reagents were compared, and their S/CO values and true positive rates were analyzed. Results Of all the 205 samples testing positive by any one reagent, 191 (93.2% tested positive by the four reagents, and 14 (6.8% were tested inconsistently by the four reagents. The positive predictive values of Xinchuang, Kehua, Wantai, and Abbott reagents were 88.2% (180/204, 93.8% (180/192, 91.4% (180/197, and 90.0% (180/200, respectively. The S/CO thresholds with a positive predictive value of ≥95% for Xinchuang, Kehua, Wantai, and Abbott reagents were 9.0, 4.0, 5.0, and 7.0, respectively. Conclusion Xinchuang, Kehua, Wantai, and Abbott reagents have significantly different S/CO thresholds with a positive predictive value of ≥95%, which are significantly different from those in other domestic laboratories. Each laboratory should establish an applicable S/CO threshold with a positive predictive value of ≥95%, in order to reduce the sample size for confirmatory test.

  13. [Research of regional medical consumables reagent logistics system in the modern hospital].

    Science.gov (United States)

    Wu, Jingjiong; Zhang, Yanwen; Luo, Xiaochen; Zhang, Qing; Zhu, Jianxin

    2013-09-01

    To explore the modern hospital and regional medical consumable reagents logistics system management. The characteristics of regional logistics, through cooperation between medical institutions within the region, and organize a wide range of special logistics activities, to make reasonable of the regional medical consumable reagents logistics. To set the regional management system, dynamic management systems, supply chain information management system, after-sales service system and assessment system. By the research of existing medical market and medical resources, to establish the regional medical supplies reagents directory and the initial data. The emphasis is centralized dispatch of medical supplies reagents, to introduce qualified logistics company for dispatching, to improve the modern hospital management efficiency, to costs down. Regional medical center and regional community health service centers constitute a regional logistics network, the introduction of medical consumable reagents logistics services, fully embodies integrity level, relevance, purpose, environmental adaptability of characteristics by the medical consumable reagents regional logistics distribution. Modern logistics distribution systems can increase the area of medical consumables reagent management efficiency and reduce costs.

  14. Treatment of laundrette wastewater using Starbon and Fenton's reagent.

    Science.gov (United States)

    Tony, Maha A; Parker, Helen L; Clark, James H

    2016-09-18

    The use of grey water for a variety of purposes is gaining increased popularity as a means of preserving scarce freshwater resources. In this work, catalytic oxidation over Fenton's reagent and adsorption techniques using Starbon (mesoporous material derived from polysaccharides) has been applied. These novel techniques are used as an alternative to already studied treatments of grey water such as filtration and/or biological processes. In this study, grey water, collected from a commercial laundrette, has been used. Treatment efficiency was determined by changes in the chemical oxygen demand (COD) of the grey water. Experiments using Fenton's reagent at optimum conditions of Fe(3+) = 40 mg L(-1); H2O2 = 400 mg L(-1) and pH 3 were very successful, resulting in a 95% COD removal after 15 min. Treatment with Starbon adsorption was also effective, reaching up to 81% COD removal at pH 3 within 1 h. The combined treatment with Fenton's reagent and Starbon resulted in a 93% COD removal at a significantly reduced concentration of Fenton's reagent compared to the treatment with solo Fenton's reagent. This lower chemical dose has the advantage of reducing costs and lowering sludge generation.

  15. Preparation of the Hexacyanoferrate Ion Exchanger Matrix to Concentrate 137Cs from Sea Water

    International Nuclear Information System (INIS)

    Murdahayu Makmur

    2007-01-01

    Preparation of the hexacyanoferrate ion exchanger matrix to concentrate 137 Cs from large volume sea water has been done. The Pre-concentration is needed because 137 Cs concentration in sea water is too low. The hexacyanoferrate ion exchanger matrix can be prepared by performing the reaction of 10 gram silica gel with potassium hexacyanoferrate on concentration variation of 0.0025 M - 0.04 M and copper chloride on concentration variation of 0.005 M - 0.08 M. The volume of each reagent was 25 ml. The performance of the ion exchanger matrix depends on the chemical compositions both of the mixtures, it was expected that no remaining Fe ion and free Cu from the initial reagent. The final effluent will analyzed for Fe and Cu using Atomic Absorption Spectrometer. The optimal molar composition ration for potassium hexacyanoferrate and copper chloride was 0.5 for 10 gram silica gel. (author)

  16. Copper-Catalyzed Oxy-Alkynylation of Diazo Compounds with Hypervalent Iodine Reagents.

    Science.gov (United States)

    Hari, Durga Prasad; Waser, Jerome

    2016-02-24

    Alkynes have found widespread applications in synthetic chemistry, biology, and materials sciences. In recent years, methods based on electrophilic alkynylation with hypervalent iodine reagents have made acetylene synthesis more flexible and efficient, but they lead to the formation of one equivalent of an iodoarene as side-product. Herein, a more efficient strategy involving a copper-catalyzed oxy-alkynylation of diazo compounds with ethynylbenziodoxol(on)e (EBX) reagents is described, which proceeds with generation of nitrogen gas as the only waste. This reaction is remarkable for its broad scope in both EBX reagents and diazo compounds. In addition, vinyl diazo compounds gave enynes selectively as single geometric isomers. The functional groups introduced during the transformation served as easy handles to access useful building blocks for synthetic and medicinal chemistry.

  17. Process for preparing multilayer enzyme coating on a fiber

    Science.gov (United States)

    Kim, Jungbae [Richland, WA; Kwak, Ja Hun [Richland, WA; Grate, Jay W [West Richland, WA

    2009-11-03

    A process for preparing high stability, high activity biocatalytic materials is disclosed and processes for using the same. The process involves coating of a material or fiber with enzymes and enzyme aggregate providing a material or fiber with high biocatalytic activity and stability useful in heterogeneous environments. In one illustrative approach, enzyme "seeds" are covalently attached to polymer nanofibers followed by treatment with a reagent that crosslinks additional enzyme molecules to the seed enzymes forming enzyme aggregates thereby improving biocatalytic activity due to increased enzyme loading and enzyme stability. This approach creates a useful new biocatalytic immobilized enzyme system with potential applications in bioconversion, bioremediation, biosensors, and biofuel cells.

  18. Fast method to determine the elements in maize flour: reduction in preparation time and reagent consumption

    Directory of Open Access Journals (Sweden)

    Irineo Kelte Filho

    2017-10-01

    Full Text Available Abstract The aim of this work was to develop and validate methodology to reduce the digestion time and reagent consumption in the determination of minerals in maize flour. The standard methodology employed in Brazil is that described by AOAC. It consists of the calcination of the sample at high temperatures for a long period of time, making the process expensive and slow. In this work, a wet sample digestion method using HNO3 was employed, heating on a block digester with final dissolution in an ultrasonic bath. The validation tests involved linearity and working range studies, and the determination of the detection and quantification limits, accuracy and precision. The sample digestion time was 1:30 h and the percent recoveries for the metals were 93% for Ca, 98% for Cu, 110% for Fe, 97% for Mg, 101% for Mn and 106% for Zn.

  19. Preparation and Evaluation of Orodispersible Tablets Containing ...

    African Journals Online (AJOL)

    wetting and disintegration times, water absorption, and in vtro dissolution. Results: Increase in ... reagent were purchased from Sigma-Aldrich (St. Louis, MO). ... pressure and the resultant solid dispersions were collected [10]. ... were prepared. Preweighed amount of the ..... It is an ideal choice for low calorie and diabetic ...

  20. Isotopically labelled vitamin D derivatives and processes for preparing same

    International Nuclear Information System (INIS)

    Deluca, H.R.; Schnoes, H.K.; Napoli, J.L.; Fivizzani, M.A.

    1981-01-01

    This invention relates to 26,27-isotopically labelled vitamin D 3 compounds, including radiolabelled vitamin D 3 compounds of high specific activity, methods for their preparation, and intermediates obtained in their synthesis. The method involves reacting an ester of a 26,27-dinor-vitamin D-25-carboxylic acid with an isotopically labelled methyl Grignard reagent or methyl lithium reagent to obtain a 26,27-isotopically labelled compound in which at least some of the H atoms and/or C atoms are heavy isotopes. (author)

  1. First-in-man open clinical trial of a combined rdESAT-6 and rCFP-10 tuberculosis specific skin test reagent.

    Directory of Open Access Journals (Sweden)

    Winnie Bergstedt

    2010-06-01

    Full Text Available Tuberculin is still the only available skin test reagent for the diagnosis of mycobacterial infection. The product has a remarkable sensitivity, but poor specificity. Previous studies, including two human phase I clinical trials, have indicated that rdESAT-6 has a potential as an improved skin test reagent. Animal studies have shown that the sensitivity may be increased by inclusion of the genetically related CFP-10 antigen in the preparation without loosing specificity.In this study a Lactococcus fermented, recombinant skin test reagent consisting of a 1ratio1 wt/wt of rdESAT-6 and CFP-10 was manufactured according to GMP standards and tested for the first time in 42 healthy adult volunteers. The two doses of 0.01 microg or 0.1 microg were injected intradermally by the Mantoux technique with 6 or 12 weeks interval. No serious adverse events and only mild adverse reactions were reported. The reagent elicited a positive skin test reaction after the first injection in one participant, who most likely was latently infected with M. tuberculosis as indicated by an appreciable IFN gamma response just below the Quantiferon(R cut-off level at the screening visit. None of the remaining participants in the four groups had any skin test reactions and sensitisation by the reagent could therefore be excluded.The investigational skin test reagent rdESAT-6 and CFP-10 appeared safe and non-sensitising in this first-in-man clinical trial in human volunteers and can now be tested in larger clinical trials involving individuals with latent M. tuberculosis infection or active TB disease.ClinicalTrials.gov NCT00793702.

  2. Hydrogen sulfide deactivates common nitrobenzofurazan-based fluorescent thiol labeling reagents.

    Science.gov (United States)

    Montoya, Leticia A; Pluth, Michael D

    2014-06-17

    Sulfhydryl-containing compounds, including thiols and hydrogen sulfide (H2S), play important but differential roles in biological structure and function. One major challenge in separating the biological roles of thiols and H2S is developing tools to effectively separate the reactivity of these sulfhydryl-containing compounds. To address this challenge, we report the differential responses of common electrophilic fluorescent thiol labeling reagents, including nitrobenzofurazan-based scaffolds, maleimides, alkylating agents, and electrophilic aldehydes, toward cysteine and H2S. Although H2S reacted with all of the investigated scaffolds, the photophysical response to each scaffold was significantly different. Maleimide-based, alkylating, and aldehydic thiol labeling reagents provided a diminished fluorescence response when treated with H2S. By contrast, nitrobenzofurazan-based labeling reagents were deactivated by H2S addition. Furthermore, the addition of H2S to thiol-activated nitrobenzofurazan-based reagents reduced the fluorescence signal, thus establishing the incompatibility of nitrobenzofurazan-based thiol labeling reagents in the presence of H2S. Taken together, these studies highlight the differential reactivity of thiols and H2S toward common thiol-labeling reagents and suggest that sufficient care must be taken when labeling or measuring thiols in cellular environments that produce H2S due to the potential for both false-positive and eroded responses.

  3. Preparation of the Reagent

    Indian Academy of Sciences (India)

    Srimath

    Analysis of carbohydrates is a significant part of qualitative organic analysis at the undergraduate level. A qualitative test that distingui- shes them from other classes of organic compounds is the Molisch test. Depending on their structure, sugars are classified ... Chemistry Department. Zakir Husain College. J.L.Nehru Marg.

  4. Targeted Diazotransfer Reagents Enable Selective Modification of Proteins with Azides.

    Science.gov (United States)

    Lohse, Jonas; Swier, Lotteke J Y M; Oudshoorn, Ruben C; Médard, Guillaume; Kuster, Bernhard; Slotboom, Dirk-Jan; Witte, Martin D

    2017-04-19

    In chemical biology, azides are used to chemically manipulate target structures in a bioorthogonal manner for a plethora of applications ranging from target identification to the synthesis of homogeneously modified protein conjugates. While a variety of methods have been established to introduce the azido group into recombinant proteins, a method that directly converts specific amino groups in endogenous proteins is lacking. Here, we report the first biotin-tethered diazotransfer reagent DtBio and demonstrate that it selectively modifies the model proteins streptavidin and avidin and the membrane protein BioY on cell surface. The reagent converts amines in the proximity of the binding pocket to azides and leaves the remaining amino groups in streptavidin untouched. Reagents of this novel class will find use in target identification as well as the selective functionalization and bioorthogonal protection of proteins.

  5. Selective Flotation of Calcite from Fluorite: A Novel Reagent Schedule

    Directory of Open Access Journals (Sweden)

    Zhiyong Gao

    2016-10-01

    Full Text Available Fluorite is an important strategic mineral. In general, fluorite ores will contain a certain amount of calcite gangue mineral. Thus, they need to be separated from each other. For an economic separation, a reverse flotation process is used to float calcite gangue from fluorite. However, little information on the separation is available. In this study, a novel reagent schedule using citric acid (CA as the depressant, sodium fluoride (NaF as the regulator and sulfoleic acid (SOA as the collector, was developed to separate calcite from fluorite. The results demonstrated a high selectivity for the flotation of calcite from fluorite using this new reagent schedule. The best selective separation for a single mineral and mixed binary minerals was obtained when 200 mg/L of NaF, 50 mg/L of CA, and 6 mg/L of SOA were used at pH 9. In addition, a batch flotation experiment was carried out using a run-of-mine feed material. Selective separation was achieved with 85.18% calcite removal while only 11.2% of fluorite was lost. An attempt was made to understand the effect of the new reagent schedule on the flotation of calcite. The results from both microflotation and bench scale flotation demonstrated a great potential for industrial application using this novel reagent schedule to upgrade fluorite ore.

  6. On-line radiation teaching materials using IT technology

    International Nuclear Information System (INIS)

    Inoue, Hiroyoshi

    2005-01-01

    We developed the on-line radiation teaching materials using the Internet, in order to provide the teaching support materials of atomic power and radiation educations in on-school study, as well as to create the complementary study system in off-school study. The themes of teaching materials were selected from requests by teachers. In the case of an elementary school, the teaching material 'an environmental problem and atomic power' was created as the aggregate of each content for study without boundary between subjects. The teaching material 'medical treatment and radiation' was created for junior high school students to raise the individual knowledge. In the case of a high school, the teaching material nucleus and radiation' was prepared to supplement the physical study of students. The on-line teaching materials were tried to 300 junior high school and high school students, 68% of students answered that the teaching material is effective to understand atomic power and radiation, though 17% answered they were not effective. Although there are problems to prepare IT learning equipments and learning follow-up system in the material, it is suggested that the on-line teaching materials will provide the novel learning system including debates for the study. This method has no limitation of time and place. (author)

  7. The activity-integrated method for quality assessment of reduning injection by on-line DPPH-CE-DAD.

    Directory of Open Access Journals (Sweden)

    Yan-xu Chang

    Full Text Available A sensitive on-line DPPH-CE-DAD method was developed and validated for both screening and determining the concentration of seven antioxidants of Reduning injection. The pH and concentrations of buffer solution, SDS, β-CD and organic modifier were studied for the detection of DPPH and seven antioxidants. By on-line mixing DPPH and sample solution, a DPPH-CE method for testing the antioxidant activity of the complex matrix was successfully established and used to screen the antioxidant components of Reduning injection. Then, antioxidant components including caffeic acid, isochlorogenic acid A, isochlorogenic acid B, isochlorogenic acid C, chlorogenic acid, neochlorogenic acid and cryptochlorogenic acid were quantified by the newly established CE-DAD method. Finally, the total antioxidant activity and the multiple active components were selected as markers to evaluate the quality of Reduning injection. The results demonstrated that the on-line DPPH-CE-DAD method was reagent-saving, rapid and feasible for on-line simultaneous determination of total pharmacological activity and contents of multi-components samples. It was also a powerful method for evaluating the quality control and mechanism of action of TCM injection.

  8. Mandelazo I as a reagent for Zr(IV) determination

    International Nuclear Information System (INIS)

    Rakha, T.H.; Filip, P.; Stefan, N.

    1984-01-01

    A spectrometric study of the reaction of the Zr(IV) ions with Mandelazo I was carried out. Absorption spectra revealed that the maximum absorption of the zirconium compound appears at a wavelength (316 nm) different from the maxima of the reagent (253 and 390 nm). Beer-Lambert law is followed for zirconium concentrations of the order of 8.8 x 10 -5 M (i.e. 8 μg Zr(IV)/mL). Possible interferences of ions such as Be(II), Cu(II), Zn(II), Al(III), Th(IV), U(VI), Mn(II), Fe(III), Co(II) and Ni(II) were investigated in connection with some masking agents such as SO 4 2- and C 2 O 4 2- . Also, the solid state Zr(IV)- Mandelazo I compound was prepared and characterized by nitrogen and thermogravimetric analyses

  9. A importância da qualidade da água reagente no laboratório clínico The importance of water quality in clinical laboratory reagent

    Directory of Open Access Journals (Sweden)

    Maria Elizabete Mendes

    2011-06-01

    Full Text Available A água é um reagente utilizado na maioria dos testes laboratoriais e por isso deve seguir um padrão de controle de qualidade rigoroso. O fornecimento urbano de água apresenta moléculas orgânicas, íons inorgânicos, partículas, coloides, gases, bactérias e seus produtos, que podem alterar os resultados dos exames laboratoriais e causar eventuais erros e falhas mecânicas em equipamentos analíticos. Para remover essas impurezas, é necessário recorrer a uma combinação de tecnologias de purificação. Há várias organizações que especificam normas sobre a água reagente, a fim de minimizar sua interferência nos ensaios laboratoriais. A maioria dos laboratórios utiliza as normas estabelecidas pelo Clinical and Laboratory Standards Institute (CLSI que classifica a água em: clinical laboratory reagent water (CLRW, special reagent water (SRW e instrumental feed water (IFW. O monitoramento da qualidade é realizado pela determinação de resistividade, condutividade, carbono orgânico total (TOC, controle microbiológico e endotoxinas. Os parâmetros são avaliados de acordo com a periodicidade estabelecida pela norma utilizada. Neste artigo, discutem-se a importância da água utilizada nos procedimentos laboratoriais, o controle da qualidade e as interferências nos ensaios laboratoriais.Water is a reagent used in most laboratory tests and, therefore, must follow stringent quality control standards. The urban water supply has organic molecules, inorganic ions, particles, colloids, gases, bacteria and their products, which may alter laboratory test results and cause occasional errors and mechanical failures in diagnostic equipment. To remove these impurities, it is necessary to use a combination of purification technologies. There are several organizations that specify reagent water standards to minimize its interference in laboratory assays. Most laboratories set standards established by the Clinical and Laboratory Standards

  10. Silver di-t-butyl phosphate, a useful reagent in the synthesis of phospholipids. Synthesis of mixed-acid phosphatidic acid and phosphatidyl glycerolphosphate

    NARCIS (Netherlands)

    Bonsen, P.P.M.; Haas, Gerard H. de

    The synthesis of silver di-t-butyl phosphate is described. Using this reagent, mixed-acid phosphatidic acid with one unsaturated fatty acid could be prepared by means of a reaction with a 1,2-diacyl glycerol-3-iodohydrin. The blocking groups could be removed easily with dry hydrogen chloride at low

  11. Effects of humidity and filter material on diffusive sampling of isocyanates using reagent-coated filters

    NARCIS (Netherlands)

    Henneken, H.; Vogel, M.; Karst, U.

    2006-01-01

    Diffusive sampling of methyl isocyanate (MIC) on 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ)-coated glass fibre (GF) filters is strongly affected by high relative humidity (RH) conditions. It is shown that the humidity interference is a physical phenomenon, based on displacement of reagent

  12. Preparation of ZnO Nanoparticles and Photocatalytic H2 Production Activity from Different Sacrificial Reagent Solutions

    Science.gov (United States)

    Peng, Tian-you; Lv, Hong-jin; Zeng, Peng; Zhang, Xiao-hu

    2011-08-01

    ZnO nanoparticles were synthesized via a direct precipitation method followed by a heterogeneous azeotropic distillation and calcination processes, and then characterized by X-ray power diffraction, scanning electron microscopy, transmission electron microscopy, and nitrogen adsorption-desorption measurement. The effects of Pt-loading amount, calcination temperature, and sacrificial reagents on the photocatalytic H2 evolution efficiency from the present ZnO suspension were investigated. The experimental results indicate that ZnO nanoparticles calcined at 400 °C exhibit the best photoactivity for the H2 production in comparison with the samples calcined at 300 and 500 °C, and the photocatalytic H2 production efficiency from a methanol solution is much higher than that from a triethanolamine solution. It can be ascribed to the oxidization of methanol also contributes to the H2 production during the photochemical reaction process. Moreover, the photocatalytic mechanism for the H2 production from the present ZnO suspension system containing methanol solution is also discussed in detail.

  13. Biosensors and preparation thereof

    NARCIS (Netherlands)

    2008-01-01

    A low-temp. prepn. method for a biosensor device with a layer of reagent on the sensor surface is disclosed. During manufg. biol. interaction between the biosensor substrate and the reagent layer material is reduced, e.g. by cooling the biosensor substrate and depositing the reagent layer on the

  14. Experimental research of the impact of the dosing of chemical reagents on the dynamic behavior of regulation system of cycle chemistry

    Science.gov (United States)

    Yegoshina, O. V.; Bolshakova, N. A.

    2017-11-01

    Organization of reliable chemical control for maintaining cycle chemistry is one of the most important problems to be solved at the present time the design and operation of thermal power plants. To maintain optimal parameters of cycle chemistry are used automated chemical control system and regulation system of dosing chemical reagents. Reliability and stability analyzer readings largely determine the reliability of the water cycle chemistry. Now the most common reagents are ammonia, alkali and film-forming amines. In this paper are presented the results of studies of the impact of concentration and composition of chemical reagents for readings stability of automatic analyzers and transients time of control systems for cycles chemistry. Research of the impact of chemical reagents on the dynamic behavior of regulation system for cycle chemistry was conducted at the experimental facility of the Department of thermal power stations of the Moscow Engineering Institute. This experimental facility is model of the work of regulation system for cycle chemistry close to the actual conditions on the energy facilities CHP. Analysis of results of the impact of chemical reagent on the dynamic behavior of ammonia and film forming amines dosing systems showed that the film-forming amines dosing system is more inertia. This emphasizes the transition process of the system, in which a half times longer dosing of ammonia. Results of the study can be used to improve the monitoring systems of water chemical treatment.

  15. Bacteriophage Mediates Efficient Gene Transfer in Combination with Conventional Transfection Reagents.

    Science.gov (United States)

    Donnelly, Amanda; Yata, Teerapong; Bentayebi, Kaoutar; Suwan, Keittisak; Hajitou, Amin

    2015-12-08

    The development of commercially available transfection reagents for gene transfer applications has revolutionized the field of molecular biology and scientific research. However, the challenge remains in ensuring that they are efficient, safe, reproducible and cost effective. Bacteriophage (phage)-based viral vectors have the potential to be utilized for general gene transfer applications within research and industry. Yet, they require adaptations in order to enable them to efficiently enter cells and overcome mammalian cellular barriers, as they infect bacteria only; furthermore, limited progress has been made at increasing their efficiency. The production of a novel hybrid nanocomplex system consisting of two different nanomaterial systems, phage vectors and conventional transfection reagents, could overcome these limitations. Here we demonstrate that the combination of cationic lipids, cationic polymers or calcium phosphate with M13 bacteriophage-derived vectors, engineered to carry a mammalian transgene cassette, resulted in increased cellular attachment, entry and improved transgene expression in human cells. Moreover, addition of a targeting ligand into the nanocomplex system, through genetic engineering of the phage capsid further increased gene expression and was effective in a stable cell line generation application. Overall, this new hybrid nanocomplex system (i) provides enhanced phage-mediated gene transfer; (ii) is applicable for laboratory transfection processes and (iii) shows promise within industry for large-scale gene transfer applications.

  16. Moderate reagent mixing on an orbital shaker reduces the incubation time of enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Kumar, Saroj; Ahirwar, Rajesh; Rehman, Ishita; Nahar, Pradip

    2017-07-01

    Rapid diagnostic tests can be developed using ELISA for detection of diseases in emergency conditions. Conventional ELISA takes 1-2 days, making it unsuitable for rapid diagnostics. Here, we report the effect of reagents mixing via shaking or vortexing on the assay timing of ELISA. A 48-min protocol of ELISA involving 12-min incubations with reagent mixing at 750 rpm for every step was optimized. Contrary to this, time-optimized control ELISA performed without mixing produced similar results in 8 h, leaving a time gain of 7 h using the developed protocol. Collectively, the findings suggest the development of ELISA-based rapid diagnostics. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Reporter-nanobody fusions (RANbodies) as versatile, small, sensitive immunohistochemical reagents.

    Science.gov (United States)

    Yamagata, Masahito; Sanes, Joshua R

    2018-02-27

    Sensitive and specific antibodies are essential for detecting molecules in cells and tissues. However, currently used polyclonal and monoclonal antibodies are often less specific than desired, difficult to produce, and available in limited quantities. A promising recent approach to circumvent these limitations is to employ chemically defined antigen-combining domains called "nanobodies," derived from single-chain camelid antibodies. Here, we used nanobodies to prepare sensitive unimolecular detection reagents by genetically fusing cDNAs encoding nanobodies to enzymatic or antigenic reporters. We call these fusions between a reporter and a nanobody "RANbodies." They can be used to localize epitopes and to amplify signals from fluorescent proteins. They can be generated and purified simply and in unlimited amounts and can be preserved safely and inexpensively in the form of DNA or digital sequence.

  18. Pre-storage of gelified reagents in a lab-on-a-foil system for rapid nucleic acid analysis

    DEFF Research Database (Denmark)

    Yi, Sun; Høgberg, Jonas; Christine, Thanner

    2013-01-01

    Reagent pre-storage in a microfluidic chip can enhance operator convenience, simplify the system design, reduce the cost of storage and shipment, and avoid the risk of cross-contamination. Although dry reagents have long been used in lateral flow immunoassays, they have rarely been used for nucle...... for fast and cost-effective POC analysis....

  19. [Experimental analysis of finishing lines in ceramometal restorations].

    Science.gov (United States)

    Gascón, F; Gil, J A; Fons, A; Badal, R

    1990-11-01

    The preparation is the first step of any tooth reconstruction. The biological integration of the protesis is depending on the marginal adaptation (finish line of the preparation), occlusal adaptation (occlusal reduction), longevity of the restoration (retention and luting) and esthetics. The effect the two finish line of the preparation is studied using experimental design. In porcelain-fused-to-metal the finish line of the preparation in chanfer is superior at the beveled shoulder, because proportioning better marginal adaptation.

  20. Field method for estimation of fluoride in drinking groundwater by photometric measurement of spot on aluminium quinalizarin reagent paper

    OpenAIRE

    Zaher Barghouthi; Sameer Amereih

    2017-01-01

    A simple field method for determination of fluoride in drinking water using handmade fluoride reagent paper impregnated by aluminium quinalizarin complex was developed. Fluoride reacts with the impregnated reagent paper to release the free ligand with new colour, orange different from that of the complex. The change in the colour, which is proportional to the amount of fluoride, was measured by the Arsenator. The functionality of the Arsenator which is based on a photometric measurement of sp...

  1. INFLUENCE OF REAGENT PURITY ON THE ION CHROMATOGRAPHIC DETERMINATION OF BROMATE IN WATER USING 3,3'-DIMETHOXYBENZIDINE AS A PROCHROMOPHORE FOR PHOTOMETRIC DETECTION

    Science.gov (United States)

    Variable availability of the purified dihydrochloride salt of 3,3'-dimethoxybenzidine (DMB, ortho-dianisidine) led us to investigate the effects of reagent purity on the analytical results obtinaed when this reagent is used in the photometric determination of the disinfection byp...

  2. On-line Automated Sample Preparation-Capillary Gas Chromatography for the Analysis of Plasma Samples.

    NARCIS (Netherlands)

    Louter, A.J.H.; van der Wagt, R.A.C.A.; Brinkman, U.A.T.

    1995-01-01

    An automated sample preparation module, (the automated sample preparation with extraction columns, ASPEC), was interfaced with a capillary gas chromatograph (GC) by means of an on-column interface. The system was optimised for the determination of the antidepressant trazodone in plasma. The clean-up

  3. Organophosphorus reagents in actinide separations: Unique tools for production, cleanup and disposal

    International Nuclear Information System (INIS)

    Nash, K. L.

    2000-01-01

    Interactions of actinide ions with phosphate and organophosphorus reagents have figured prominently in nuclear science and technology, particularly in the hydrometallurgical processing of irradiated nuclear fuel. Actinide interactions with phosphorus-containing species impact all aspects from the stability of naturally occurring actinides in phosphate mineral phases through the application of the bismuth phosphate and PUREX processes for large-scale production of transuranic elements to the development of analytical separation and environment restoration processes based on new organophosphorus reagents. In this report, an overview of the unique role of organophosphorus compounds in actinide production, disposal, and environment restoration is presented. The broad utility of these reagents and their unique chemical properties is emphasized

  4. Development of versatile universal reagent immunoradiometric assay technique

    International Nuclear Information System (INIS)

    Hazra, D.K.

    1982-10-01

    Immunoradiometric assays, which make use of labelled antibodies, potentially offer better sensitivity and specificity than do radioimmunoassays, which use labelled antigens. In addition, they can in principle be performed in a particularly convenient scheme wherein the same labelled reagent may be used for many different analytes - thus serving as a ''universal'' labelled reagent. Thus if the specific antibody for every analyte is raised in rabbits, and an anti-rabbit antibody is labelled, the latter may be added after the specific antibody to quantify the amount of specific antibody bound to analyte and thereby the amount of analyte present. The potential greater sensitivity and specificity of the immunoradiometric procedure, coupled with the potential convenience of the ''universal'' labelled reagent, might allow such immunoradiometric techniques to be used effectively in the study of communicable diseases in developing countries. Development of these procedures was the subject of this investigation. Many components of these procedures had to be explored and provisionally optimized, including coating of assay tubes with ''extraction'' antibody, immunological purification of antibodies, labelling of antibodies, and intermediate steps toward these goals. Applications were thereupon tested using those provisionally optimized components. The ''universal'' labelled reagent, a donkey anti-rabbit antiserum, was successfully used in the assay of TSH; however, cross reactions of the reagent with non-rabbit immunoglobulins and other materials present seriously limited the sensitivity of the method. Using conventional immunoradiometric procedures, circulating TB and amoebic antibodies could be detected in patients suffering from these diseases. Similarly, circulating antigens in the same patients could also be detected, but not with sufficient sensitivity and specificity to provide a reliable analytical system. Numerous improvements will be required before these techniques

  5. Reagents for the assay of cardenolide glycosides and aglycones

    International Nuclear Information System (INIS)

    Wilkinson, S.

    1976-01-01

    Some novel reagents are described for use in the radioimmunoassay of the 3-glycone derivatives of cardenolides (cardiac glycosides) and more especially digoxin, digitoxin, gitoxin, periplocin and lanatosides. Using these reagents these cardenolides and their derivatives may be assayed both in aqueous solution and in urine. A method is also described for performing such assays, including a suitable kit. (U.K.)

  6. Preparation of curcumin microemulsions with food-grade soybean oil/lecithin and their cytotoxicity on the HepG2 cell line.

    Science.gov (United States)

    Lin, Chuan-Chuan; Lin, Hung-Yin; Chi, Ming-Hung; Shen, Chin-Min; Chen, Hwan-Wen; Yang, Wen-Jen; Lee, Mei-Hwa

    2014-07-01

    The choice of surfactants and cosurfactants for preparation of oral formulation in microemulsions is limited. In this report, a curcumin-encapsulated phospholipids-based microemulsion (ME) using food-grade ingredients soybean oil and soybean lecithin to replace ethyl oleate and purified lecithin from our previous study was established and compared. The results indicated soybean oil is superior to ethyl oleate as the oil phase in curcumin microemulsion, as proven by the broadened microemulsion region with increasing range of surfactant/soybean oil ratio (approx. 1:1-12:1). Further preparation of two formula with different particle sizes of formula A (30nm) and B (80nm) exhibited differential effects on the cytotoxicity of hepatocellular HepG2 cell lines. At 15μM of concentration, curcumin-ME in formula A with smaller particle size resulted in the lowest viability (approx. 5%), which might be explained by increasing intake of curcumin, as observed by fluorescence microscopy. In addition, the cytotoxic effect of curcumin-ME is exclusively prominent on HepG2, not on HEK293, which showed over 80% of viability at 15μM. The results from this study might provide an innovative applied technique in the area of nutraceuticals and functional foods. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Diagnostic PCR: validation and sample preparation are two sides of the same coin

    DEFF Research Database (Denmark)

    Hoorfar, Jeffrey; Wolffs, Petra; Radstrøm, Peter

    2004-01-01

    Increased use of powerful PCR technology for the routine detection of pathogens has focused attention on the need for international validation and preparation of official non-commercial guidelines. Bacteria of epidemiological importance should be the prime focus, although a "validation...... of quantitative reference DNA material and reagents, production of stringent protocols and tools for thermal cycler performance testing, uncomplicated sample preparation techniques, and extensive ring trials for assessment of the efficacy of selected matrix/pathogen detection protocols....

  8. Inactivation of viable Ascaris eggs by reagents during enumeration.

    Science.gov (United States)

    Nelson, K L; Darby, J L

    2001-12-01

    Various reagents commonly used to enumerate viable helminth eggs from wastewater and sludge were evaluated for their potential to inactivate Ascaris eggs under typical laboratory conditions. Two methods were used to enumerate indigenous Ascaris eggs from sludge samples. All steps in the methods were the same except that in method I a phase extraction step with acid-alcohol (35% ethanol in 0.1 N H(2)SO(4)) and diethyl ether was used whereas in method II the extraction step was avoided by pouring the sample through a 38-microm-mesh stainless steel sieve that retained the eggs. The concentration of eggs and their viability were lower in the samples processed by method I than in the samples processed by method II by an average of 48 and 70%, respectively. A second set of experiments was performed using pure solutions of Ascaris suum eggs to elucidate the effect of the individual reagents and relevant combination of reagents on the eggs. The percentages of viable eggs in samples treated with acid-alcohol alone and in combination with diethyl ether or ethyl acetate were 52, 27, and 4%, respectively, whereas in the rest of the samples the viability was about 80%. Neither the acid nor the diethyl ether alone caused any decrease in egg viability. Thus, the observed inactivation was attributed primarily to the 35% ethanol content of the acid-alcohol solution. Inactivation of the eggs was prevented by limiting the direct exposure to the extraction reagents to 30 min and diluting the residual concentration of acid-alcohol in the sample by a factor of 100 before incubation. Also, the viability of the eggs was maintained if the acid-alcohol solution was replaced with an acetoacetic buffer. None of the reagents used for the flotation step of the sample cleaning procedure (ZnSO(4), MgSO(4), and NaCl) or during incubation (0.1 N H(2)SO(4) and 0.5% formalin) inactivated the Ascaris eggs under the conditions studied.

  9. Use of Competition Kinetics with Fast Reactions of Grignard Reagents

    DEFF Research Database (Denmark)

    Holm, Torkil

    2000-01-01

    small.This is concluded from experiments in which results obtained by competition kinetics are compared with results obtained directly by flow stream procedures. A clearer picture of the reactivity ratios is obtained when the highly reactive reagent is highly diluted with its competitor. A fast reagent...

  10. Simultaneous determination of glucose, triglycerides, urea, cholesterol, albumin and total protein in human plasma by Fourier transform infrared spectroscopy: direct clinical biochemistry without reagents.

    Science.gov (United States)

    Jessen, Torben E; Höskuldsson, Agnar T; Bjerrum, Poul J; Verder, Henrik; Sørensen, Lars; Bratholm, Palle S; Christensen, Bo; Jensen, Lene S; Jensen, Maria A B

    2014-09-01

    Direct measurement of chemical constituents in complex biologic matrices without the use of analyte specific reagents could be a step forward toward the simplification of clinical biochemistry. Problems related to reagents such as production errors, improper handling, and lot-to-lot variations would be eliminated as well as errors occurring during assay execution. We describe and validate a reagent free method for direct measurement of six analytes in human plasma based on Fourier-transform infrared spectroscopy (FTIR). Blood plasma is analyzed without any sample preparation. FTIR spectrum of the raw plasma is recorded in a sampling cuvette specially designed for measurement of aqueous solutions. For each analyte, a mathematical calibration process is performed by a stepwise selection of wavelengths giving the optimal least-squares correlation between the measured FTIR signal and the analyte concentration measured by conventional clinical reference methods. The developed calibration algorithms are subsequently evaluated for their capability to predict the concentration of the six analytes in blinded patient samples. The correlation between the six FTIR methods and corresponding reference methods were 0.87albumin and total protein in human plasma. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. On-line pre-reduction of Se(VI) by thiourea for selenium speciation by hydride generation

    International Nuclear Information System (INIS)

    Qiu Jianhua; Wang Qiuquan; Ma Yuning; Yang Limin; Huang Benli

    2006-01-01

    In this study, thiourea (TU) was novelly developed as a reduction reagent for on-line pre-reduction of selenium(VI) before conventional hydride generation (HG) by KBH 4 /NaOH-HCl. After TU on-line pre-reduction, the HG efficiency of Se(VI) has been greatly improved and because even higher than that of the same amount of Se(IV) obtained in the conventional HG system. The possible pre-reduction mechanism is discussed. The detection limit (DL) of selenate reaches 10 pg mL -1 when using on-line TU pre-reduction followed by HG atomic fluorescence detection. When TU pre-reduction followed by HG is used as an interface between ion-pair high performance liquid chromatography and atomic fluorescence spectrometry, selenocystine, selenomethionine, selenite and selenate can be measured simultaneously and quantitatively. The DLs of these are 0.06, 0.08, 0.05 and 0.04 ng mL -1 , respectively, and the relative standard deviations of 9 duplicate runs for all the 4 species are less than 5%. Furthermore, it was successfully applied to Se speciation analysis of cultured garlic samples, and validated by determination of total selenium and selenium species in certified reference material NIST 1946

  12. One-pot catalyst preparation : combined detemplating and Fe ionexchange of BEA through Fenton's chemistry

    NARCIS (Netherlands)

    Melián-Cabrera, I.; Kapteijn, F.; Moulijn, J.A.

    2005-01-01

    BEA zeolite has been simultaneously detemplated and Fe-exchanged by treating the parent zeolite with a Fenton's-type reagent (Fe3+ - H2O2) at low temperature. This one-pot process simplifies and speeds up considerably the preparation route. The catalyst shows excellent performance on N2O

  13. Fecal specimens preparation methods for PCR diagnosis of human taeniosis

    Directory of Open Access Journals (Sweden)

    Nunes Cáris Maroni

    2006-01-01

    Full Text Available Sample preparation and DNA extraction protocols for DNA amplification by PCR, which can be applied in human fecal samples for taeniasis diagnosis, are described. DNA extracted from fecal specimens with phenol/chloroform/isoamilic alcohol and DNAzol® reagent had to be first purified to generate fragments of 170 pb and 600 pb by HDP2-PCR. This purification step was not necessary with the use of QIAmp DNA stool mini kit®. Best DNA extraction results were achieved after eggs disruption with glass beads, either with phenol/chloroform/isoamilic alcohol, DNAzol® reagent or QIAmp DNA stool mini kit®.

  14. On-line monitoring of monoclonal antibody formation in high density perfusion culture using FIA.

    Science.gov (United States)

    Fenge, C; Fraune, E; Freitag, R; Scheper, T; Schügerl, K

    1991-05-01

    An automated flow injection system for on-line analysis of proteins in real fermentation fluids was developed by combining the principles of stopped-flow, merging zones flow injection analysis (FIA) with antigen-antibody reactions. IgG in the sample reacted with its corresponding antibody (a-IgG) in the reagent solution. Formation of insoluble immunocomplexes resulted in an increase of the turbidity which was determined photometrically. This system was used to monitor monoclonal antibody production in high cell density perfusion culture of hybridoma cells. Perfusion was performed with a newly developed static filtration unit equipped with hydrophilic microporous tubular membranes. Different sampling devices were tested to obtain a cell-free sample stream for on-line product analysis of high molecular weight (e.g., monoclonal antibodies) and low molecular weight (e.g., glucose, lactate) medium components. In fermentation fluids a good correlation (coefficient: 0.996) between the FIA method and an ELISA test was demonstrated. In a high density perfusion cultivation process mAb formation was successfully monitored on-line over a period of 400 h using a reliable sampling system. Glucose and lactate were measured over the same period of time using a commercially available automatic analyser based on immobilized enzyme technology.

  15. [Thermodynamic forecasting of reagents composition for soils decontamination].

    Science.gov (United States)

    Nikolaev, V P; Nikolaevskiĭ, V B; Chirkina, I V; Shcheglov, M Iu

    2009-01-01

    Based on thermodynamic studies, the authors conducted laboratory experiments on searching optimal composition of leaching reagents solution for soils decontamination, when contaminated with Cs-137, of activity coefficient for caesium sulfate microquantities in macrocomponents solutions. The method could be used for modelling the radionuclides phase equillibrium and relocations in soils.

  16. Field-Portable Immunoassay Instruments and Reagents to Measure Chelators and Mobile Forms of Uranium

    International Nuclear Information System (INIS)

    Blake, Diane A.

    2006-01-01

    Progress Report Date: 01/23/06 (report delayed due to Hurricane Katrina) Report of results to date: The goals of this 3-year project are to: (1) update and successfully deploy our present immunosensors at DOE sites; (2) devise immunosensor-based assays for Pb(II), Hg(II), chelators, and/or Cr(III) in surface and groundwater; and (3) develop new technologies in antibody engineering that will enhance this immunosensor program. Note: Work on this project was temporarily disrupted when Hurricane Katrina shut down the University on August 29, 2005. While most of the reagents stored in our refrigerators and freezers were destroyed, all of our hybridoma cell lines were saved because they had been stored in liquid nitrogen. We set up new tissue culture reactors with the hybridomas that synthesize the anti-uranium antibodies, and are purifying new monoclonal antibodies from these culture supernatants. Both the in-line and the field-portable sensor were rescued from our labs in New Orleans in early October, and we continued experiments with these sensors in the temporary laboratory we set up in Hammond, LA at Southeastern Louisiana University

  17. Estimation of 239Pu in urine, influence of Sulkowich reagent

    International Nuclear Information System (INIS)

    Kalaiselvan, S.; Prasad, M.V.R.; Jeevanram, R.K.

    1988-01-01

    Plutonium is known to be co-precipitated with Sulkowich reagent as calcium ammonium oxalate. In adopting this technique for bio-assay of plutonium, its accuracy depends on the self-absorption of the resulting precipitate in each urine sample. Pu recovery experiments were carried out with varying concentration of Ca and Mg, using different volumes of Sulkowich reagent. When the sample volume is 500 ml, Pu in urine can be estimated with an accuracy and precision of 74.38%+-7.4%, with a detection limit of 0.06 Bq (1.6 pCi) per dm 3 . (author) 3 refs.; 2 figs.; 2 tabs

  18. Mössbauer spectroscopy research of interaction of alumosilicic reagent and iron dissolved in water

    International Nuclear Information System (INIS)

    Feklistov, D Y; Filippov, V P; Kurchatov, I M; Laguntsov, N I; Salomasov, V A; Permyakov, Yu V

    2016-01-01

    The aim of this work is to reveal the results of alumosilicic reagent interaction with iron compounds contained in the water. This reagent is simultaneously coagulant-flocculant and adsorbent. The iron atoms state is studied in the reagent and in reacted sediment. The valence state of iron atoms are determined in the reagents and sediments. The existence of iron containing superparamagnetic particles in the sediment is shown. (paper)

  19. Preparation, assay and certification of aqueous ethanol reference solutions

    CSIR Research Space (South Africa)

    Archer, M

    2007-04-01

    Full Text Available with traceability to the SI. Ethanol solutions in the concentration range 10 mg/100 g to 20 g/100 g are prepared gravimetrically by mixing ethanol and reagent quality water. To verify the concentration of the ethanol it is oxidized to acetic acid with potassium...

  20. Kalman filtering applied to a reagent feed system

    International Nuclear Information System (INIS)

    Griffin, C.D.; Croson, D.V.; Feeley, J.J.

    1988-01-01

    Using a Kalman filter solves a troublesome measurement noise problem and, at the same time, improves nuclear safety by detecting leaks to the process' feed tanks. To demonstrate how this technology of optimal estimation can be exploited, this article presents a systematic plan and example of how a Kalman filter was proven in industrial use on a reagent analyzer. A process to recycle uranium from spent fuel elements uses a reagent stream containing boron to dissolve the fuel. The boron is the neutron poison that prevents a nuclear chain reaction during the uranium dissolution. The purpose of the Kalman filter for this system is to reduce the uncertainty in the boron concentration measurement. The filter also provides incipient fault detection by estimating the unmeasured state of any unpoisoned solution, which would dilute the boron solution, entering the feed vessel

  1. Selective-Reagent-Ionization Mass Spectrometry: New Prospects for Atmospheric Research

    Science.gov (United States)

    Sulzer, Philipp; Jordan, Alfons; Hartungen, Eugen; Hanel, Gernot; Jürschik, Simone; Herbig, Jens; Märk, Lukas; Märk, Tilmann D.

    2014-05-01

    Proton-Transfer-Reaction Mass Spectrometry (PTR-MS), which was introduced to the scientific community in the 1990's, has quickly evolved into a well-established technology for atmospheric research and environmental chemistry [1]. Advantages of PTR-MS are i) high sensitivities of several hundred cps/ppbv, ii) detection limits at or below the pptv level, iii) direct injection sampling (i.e. no sample preparation), iv) response times in the 100 ms regime and v) online quantification. However, one drawback is a somehow limited selectivity, as in case of quadrupole mass filter based instruments only information about nominal m/z are available. In Time-Of-Flight (TOF) mass analyzer based instruments selectivity is drastically increased by a high mass resolution of up to 8000 m/Δm, but e.g. isomers still cannot be separated. In 2009 we introduced an advanced version of PTR-MS, which permits switching the reagent ions from H3O+ to NO+ and O2+, respectively [2]. This novel type of instrumentation was called Selective-Reagent-Ionization Mass Spectrometry (SRI-MS) and has been successfully used to separate isomers, e.g. the biogenic compounds isoprene and 2-methyl-3-buten-2-ol as shown by Karl et al. [3]. Switching the reagent ions dramatically increases selectivity and thus applicability of SRI-MS in atmospheric research. Here we report on the latest results utilizing an even more advanced embodiment of SRI-MS enabling the use of the additional reagent ions Kr+ and Xe+ [4]. With this technology important atmospheric compounds, such as CO2, CO, CH4, O2, etc. can be quantified and selectivity is increased even further. We present comparison data between diesel and gasoline car exhaust gases and quantitative data on indoor air for these compounds, which are not detectable with classical PTR-MS. Additionally, we show very recent examples of isomers which cannot be separated with PTR-MS but can clearly be distinguished with SRI-MS. Finally, we give an overview of ongoing SRI

  2. Genetic and Genomic Characterization of 462 Melanoma Patient-Derived Xenografts, Tumor Biopsies, and Cell Lines

    Directory of Open Access Journals (Sweden)

    Bradley Garman

    2017-11-01

    Full Text Available Summary: Tumor-sequencing studies have revealed the widespread genetic diversity of melanoma. Sequencing of 108 genes previously implicated in melanomagenesis was performed on 462 patient-derived xenografts (PDXs, cell lines, and tumors to identify mutational and copy number aberrations. Samples came from 371 unique individuals: 263 were naive to treatment, and 108 were previously treated with targeted therapy (34, immunotherapy (54, or both (20. Models of all previously reported major melanoma subtypes (BRAF, NRAS, NF1, KIT, and WT/WT/WT were identified. Multiple minor melanoma subtypes were also recapitulated, including melanomas with multiple activating mutations in the MAPK-signaling pathway and chromatin-remodeling gene mutations. These well-characterized melanoma PDXs and cell lines can be used not only as reagents for a large array of biological studies but also as pre-clinical models to facilitate drug development. : Garman et al. have characterized melanoma PDXs and cell lines described in Krepler et al. (see the related paper in this issue of Cell Reports, identifying major and minor subtypes, some of which were previously not well defined, targeted and immunotherapy resistance, and tumor heterogeneity, creating a set of reagents for future drug discovery and biological studies. Keywords: melanoma, patient-derived xenografts, massively parallel sequencing, cell lines

  3. Oxidative Degradation of Phenol containing Wastewater using Fenton Reagent, Permanganate and Ultraviolet Radiation

    International Nuclear Information System (INIS)

    Abd El-Rahman, N.M.; Talaat, H.A.; Sorour, M.H.

    1999-01-01

    Phenol containing wastewaters are generated by numerous industrial units including integrated steel mills, textile mills, plastic production, etc. The present work is targeted to explore the viable oxidation techniques for degradation of phenolic wastewater. Three modes of treatment have been adopted in this study, namely, sole oxidant mode using Fenton reagent or permanganate, UV-assisted oxidation and two consequent chemical oxidation steps. Results indicated the superiority of fenton reagent over KMnO 4 oxidation in the sole oxidant mode. On the other hand, UV-assisted KMnO 4 oxidation enables almost complete COD reduction. Dual chemical oxidation mode employing KMnO 4 oxidation followed by Fenton reagent is also an efficient oxidative degradation system

  4. Potassium N-Iodo p-Toluenesulfonamide (TsNIK, Iodamine-T): A New Reagent for the Oxidation of Hydrazones to Diazo Compounds

    Science.gov (United States)

    Nicolle, Simon M; Moody, Christopher J

    2014-01-01

    A new reagent for the oxidation of hydrazones to diazo compounds is described. N-Iodo p-toluenesulfonamide (TsNIK, iodamine-T) allows the preparation of α-diazoesters, α-diazoamides, α-diazoketones and α-diazophosphonates in good yield and in high purity after a simple extractive work-up. α-Diazoesters were also obtained in high yield from the corresponding ketones through a one-pot process of hydrazone formation/oxidation. PMID:24615944

  5. Reagent conditions of the flotation of copper, copper - molybdenum and copper -zinc ores in foreing countries

    International Nuclear Information System (INIS)

    Nevaeva, L.M.

    1983-01-01

    Reagents-collectors and frothers, used abroad in reagent regimes of flotation of copper, copper-molybdenum and copper zinc ores, have been considered. Xanthogenates, aerofloats, xanthogenformiates, thionocarbamates are mainly used as reagents-collectors. Methylizobutylcarbinol and Daufros are used as reagents-frothers

  6. 21 CFR 866.3120 - Chlamydia serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3120 Chlamydia... and antisera used in serological tests to identify antibodies to chlamydia in serum. Additionally...

  7. 21 CFR 866.3490 - Rhinovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3490 Rhinovirus... and antisera used in serological tests to identify antibodies to rhinovirus in serum. The...

  8. 21 CFR 866.3020 - Adenovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3020 Adenovirus... identify adenoviruses directly from clinical specimens. The identification aids in the diagnosis of disease...

  9. 21 CFR 866.3205 - Echovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3205 Echovirus... echoviruses from clinical specimens or from tissue culture isolates derived from clinical specimens. The...

  10. A Perspective on Reagent Diversity and Non-covalent Binding of Reactive Carbonyl Species (RCS and Effector Reagents in Non-enzymatic Glycation (NEG: Mechanistic Considerations and Implications for Future Research

    Directory of Open Access Journals (Sweden)

    Kenneth J. Rodnick

    2017-06-01

    Full Text Available This perspective focuses on illustrating the underappreciated connections between reactive carbonyl species (RCS, initial binding in the nonenzymatic glycation (NEG process, and nonenzymatic covalent protein modification (here termed NECPM. While glucose is the central species involved in NEG, recent studies indicate that the initially-bound glucose species in the NEG of human hemoglobin (HbA and human serum albumin (HSA are non-RCS ring-closed isomers. The ring-opened glucose, an RCS structure that reacts in the NEG process, is most likely generated from previously-bound ring-closed isomers undergoing concerted acid/base reactions while bound to protein. The generation of the glucose RCS can involve concomitantly-bound physiological species (e.g., inorganic phosphate, water, etc.; here termed effector reagents. Extant NEG schemes do not account for these recent findings. In addition, effector reagent reactions with glucose in the serum and erythrocyte cytosol can generate RCS (e.g., glyoxal, glyceraldehyde, etc.. Recent research has shown that these RCS covalently modify proteins in vivo via NECPM mechanisms. A general scheme that reflects both the reagent and mechanistic diversity that can lead to NEG and NECPM is presented here. A perspective that accounts for the relationships between RCS, NEG, and NECPM can facilitate the understanding of site selectivity, may help explain overall glycation rates, and may have implications for the clinical assessment/control of diabetes mellitus. In view of this perspective, concentrations of ribose, fructose, Pi, bicarbonate, counter ions, and the resulting RCS generated within intracellular and extracellular compartments may be of importance and of clinical relevance. Future research is also proposed.

  11. Reagent precipitation of copper ions from wastewater of machine-building factories

    Science.gov (United States)

    Porozhnyuk, L. A.; Lupandina, N. S.; Porozhnyuk, E. V.

    2018-03-01

    The article presents the results of reagent removal of copper ions from wastewater of machine-building factories. The urgency of the study is conditioned by the widening of the range of effective reagents through the implementation of industrial waste. The investigation covers mineralogical and fractional composition of chalk enrichment waste. In the work, the conditions of thermal activation of chalk enrichment waste used for reagent removal of copper ions from wastewater were elaborated. It was shown that the thermal activation of waste facilitates the increased treatment efficacy up to the set sanitation, hygiene and technological standards.

  12. Conversion of coal mine drainage ochre to water treatment reagent: Production, characterisation and application for P and Zn removal.

    Science.gov (United States)

    Sapsford, Devin; Santonastaso, Marco; Thorn, Peter; Kershaw, Steven

    2015-09-01

    Coal mine drainage ochre is a ferruginous precipitate that forms from mine water in impacted watercourses and during treatment. With thousands of tonnes per annum of such ochre arising from mine water treatment in the UK alone, management of these wastes is a substantive issue. This paper demonstrates that the ochre from both active and passive treatment of coal mine drainage can be transformed into an effective water treatment reagent by simple acid dissolution and that the reagent can be used for the removal of dissolved phosphorous from municipal wastewater and zinc from non-coal mine waters. Ochre is readily soluble in H2SO4 and HCl. Ochre is more soluble in HCl with solubilities of up to 100 g/L in 20% (w/w) HCl and 68 g/L in 10% (w/w) H2SO4. For four of the eight tested ochres solubility decreased in higher concentrations of H2SO4. Ochre compositional data demonstrate that the coal mine ochres tested are relatively free from problematic levels of elements seen by other authors from acid mine drainage-derived ochre. Comparison to British Standards for use of iron-based coagulants in drinking water treatment was used as an indicator of the acceptability of use of the ochre-derived reagents in terms of potentially problematic elements. The ochre-derived reagents were found to meet the 'Grade 3' specification, except for arsenic. Thus, for application in municipal wastewater and mine water treatment additional processing may not be required. There was little observed compositional difference between solutions prepared using H2SO4 or HCl. Ochre-derived reagents showed applicability for the removal of P and Zn with removals of up to 99% and 97% respectively measured for final pH 7-8, likely due to sorption/coprecipitation. Furthermore, the results demonstrate that applying a Fe dose in the form of liquid reagent leads to a better Fe:P and Fe:Zn removal ratio compared to ochre-based sorption media tested in the literature. Copyright © 2015 The Authors. Published by

  13. 21 CFR 866.3470 - Reovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3470 Reovirus... and antisera used in serological tests to identify antibodies to reovirus in serum. The identification...

  14. Design, synthesis, and validation of an in vitro platform peptide-whole cell screening assay using MTT reagent

    Directory of Open Access Journals (Sweden)

    Sahar Ahmed

    2017-05-01

    Full Text Available An in vitro platform to perform peptide screening against different cancer cell lines was designed. The strategy for this screening relied on the design and detection of high-affinity cancer-targeting peptides based on the sequences of NGR and P160. Evaluation of the best binding peptides was performed via incubation of the peptide array-bounded cells with MTT reagent, which is reduced to purple formazan in living cells and further quantified using an Elispot and Kodak imager. For proof of concept, a peptide library (132 spots, and 66 different peptides was designed, synthesized, and screened against different cancer cell lines. The current strategy assists in the identification of positive and negative peptides as well as the relative binding between positive ones. Better binding peptide sequences of the NGR motif were demonstrated to show up to a 2.6-fold increase in CD13+ cell lines with insignificant binding to CD13− ones. Comparable results were observed for P160 peptide sequences, to which different peptides had increased binding, with an up to 3-fold increase relative to the native P160 peptide. Based on our results, new peptide sequences for cancer targeting were identified, and the developed strategy was applied to two different peptide libraries.

  15. Drifter technique: a new method to obtain metaphases in Hep-2 cell line cultures

    Directory of Open Access Journals (Sweden)

    Eleonidas Moura Lima

    2005-07-01

    Full Text Available The Hep-2 cell line is derived from laryngeal carcinoma cells and is often utilized as a model in carcinogenesis and mutagenesis tests. To evaluate the proliferative potential of this line, we developed a cytogenetic methodology (drifter technique to obtain metaphases from cells that loose cellular adhesion when they underwent mitosis in culture. By this procedure, 2000 cells were counted, resulting in a mitotic index (MI of 22.2%. Although this MI was not statistically different from the one obtained using either a classical cytogenetic method or a cell synchronization technique, the drifter technique has the advantage of not requiring the use of some reagents for the obtention of metaphases and also of diminishing the consumption of maintenance reagents for this cell line.A linhagem celular Hep-2 é formada por células de carcinoma da laringe e é muito utilizada em modelos de carcinogênese e mutagenêse. Para avaliar o potencial proliferativo desta linhagem, desenvolvemos uma metodologia citogenética (técnica do sobrenadante para obtenção de metáfases a partir de células que, ao entrarem em mitose, perdem adesão celular, ficando em suspensão no meio de cultura. Através deste procedimento, foram contadas 2000 células, correspondendo a um índice mitótico (IM de 22.2% . Apesar de o IM obtido por esta técnica não ter sido estatisticamente diferente do IM obtido por outras metodologias citogenéticas clássicas, a técnica do sobrenadante é vantajosa porque elimina o uso de alguns reagentes utilizados na obtenção de metáfases e também diminui o consumo de reagentes de manutenção desta linhagem.

  16. Cytotoxicity effect of Zataria multiflora Boiss. on two human colon carcinoma cell lines

    Directory of Open Access Journals (Sweden)

    F. Sharififar

    2017-10-01

    Full Text Available Background and objectives: Natural products are one of the major sources for investigations of novel medicines. Zataria multiflora Boiss (ZM has shown pharmacological activities especially in gastrointestinal tract; however, there are limited studies about its cytotoxicity effects. In this study, the effect of Zataria multiflora was examined on two colon cancer cell lines (SW-48 and HT-29. Methods: Hydro-alcoholic extract of ZM and its fractions including chloroform, petroleum ether and methanol extract were prepared by warm maceration method. Different concentrations were prepared and examined on SW-48 and HT-29 cell lines using 2-(4, 5-dimethylthiazol-2-yl 2, 5-diphenyltetrazolium bromide (MTT assay. Results: The results of the present study have shown the cytotoxic effect of some fractions of ZM. The most considerable cytotoxic effect was shown against HT-29 cell line. Also, total ZM extract and the petroleum ether fraction demonstrated cytotoxic effects with IC50 values of 44.22 and 33.42 µg/ml on SW-48 and HT-29 cell lines, respectively. Conclusion: Zataria multiflora was cytotoxic to against colon cancer cell lines HT-29 and SW-48.

  17. Data on final calcium concentration in native gel reagents determined accurately through inductively coupled plasma measurements

    Directory of Open Access Journals (Sweden)

    Jeffrey Viviano

    2016-03-01

    Full Text Available In this article we present data on the concentration of calcium as determined by Inductively Coupled Plasma (ICP measurements. Calcium was estimated in the reagents used for native gel electrophoresis of Neuronal Calcium Sensor (NCS proteins. NCS proteins exhibit calcium-dependent mobility shift in native gels. The sensitivity of this shift to calcium necessitated a precise determination of calcium concentrations in all reagents used. We determined the calcium concentrations in different components used along with the samples in the native gel experiments. These were: 20 mM Tris pH 7.5, loading dye and running buffer, with distilled water as reference. Calcium determinations were through ICP measurements. It was found that the running buffer contained calcium (244 nM over the blank. Keywords: Neuronal calcium sensor proteins, Electrophoresis, Mobility shift, Calcium, Magnesium

  18. Preparation of pyrrolizinone derivatives via sequential transformations of cyclic allyl imides: synthesis of quinolactacide and marinamide.

    Science.gov (United States)

    Simic, Milena; Tasic, Gordana; Jovanovic, Predrag; Petkovic, Milos; Savic, Vladimir

    2018-03-28

    A facile synthetic route has been developed for the preparation of pyrrolizinone derivatives employing N-allyl imides as starting materials. The nucleophilic addition of a vinyl Grignard reagent/RCM/elimination sequence afforded pyrrolizinones in good yields and has been applied for the preparation of naturally occurring quinolactacide and marinamide.

  19. Competitive roles of reagent vibration and translation in the exothermic proton transfer reaction H+2+Ar→HAr++H

    International Nuclear Information System (INIS)

    Bilotta, R.M.; Farrar, J.M.

    1981-01-01

    We present a crossed beam study of the title reaction at fixed collision energies of 1.2 and 2.3 eV with reagent H + 2 average vibrational energies of 0.44 and 0.89 eV; we also present data at fixed total energies with variable proportions of reagent vibrational and translational energy. At fixed collision energy, reagent vibrational excitation is found to have negligible effect on the total cross section for proton transfer. At fixed total energy, a decrease in reagent vibrational excitation with a corresponding increase in reagent translation leads to partial disposal of the incremental translation in product translation: At a total energy of 3.5 eV, 50% of this incremental reagent translation appears as product translation. At a total energy of 4.6 eV, 78% of the incremental translation appears in product translation. The experimental data are discussed in terms of induced attractive and repulsive energy release on an attractive potential surface. The role of noncollinear geometries and compressed reactant configurations is judged to be of substantial importance in assessing product rotational excitation and dissociation

  20. Interaction of Celestine Concentrate and Reagent Grade SrSO4 with Oxalate Solutions

    Directory of Open Access Journals (Sweden)

    Abdullah Obut

    2012-12-01

    Full Text Available The interaction of reagent grade strontium sulphate and celestine concentrate with aqueous solutions of oxalic acid, sodiumoxalate and ammonium oxalate for the production of strontium carbonate were investigated for different oxalate compound:SrSO4 moleratios and reaction times using x-ray diffraction analysis and dissolution tests. Under the same experimental conditions, it was foundthat aqueous oxalic acid and sodium oxalate solutions had no or little effect on reagent grade strontium sulphate or celestineconcentrate, but aqueous ammonium oxalate solution converted them into strontium oxalate hydrate. Strontium carbonate was obtainedat conversion ratios of 74.7% for the celestine concentrate and 84.6 % for the reagent grade strontium sulphate by the decompositionof the obtained strontium oxalate hydrate at 600 °C under air atmosphere.

  1. 21 CFR 864.9650 - Quality control kit for blood banking reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Quality control kit for blood banking reagents... SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That Manufacture Blood and Blood Products § 864.9650 Quality control kit for blood banking reagents. (a...

  2. Visualising substrate-fingermark interactions: Solid-state NMR spectroscopy of amino acid reagent development on cellulose substrates.

    Science.gov (United States)

    Spindler, Xanthe; Shimmon, Ronald; Roux, Claude; Lennard, Chris

    2015-05-01

    Most spectroscopic studies of the reaction products formed by ninhydrin, 1,2-indanedione-zinc (Ind-Zn) and 1,8-diazafluoren-9-one (DFO) when reacted with amino acids or latent fingermarks on paper substrates are focused on visible absorption or luminescence spectroscopy. In addition, structural elucidation studies are typically limited to solution-based mass spectrometry or liquid nuclear magnetic resonance (NMR) spectroscopy, which does not provide an accurate representation of the fingermark development process on common paper substrates. The research presented in this article demonstrates that solid-state carbon-13 magic angle spinning NMR ((13)C-MAS-NMR) is a technique that can not only be utilised for structural studies of fingermark enhancement reagents, but is a promising technique for characterising the effect of paper chemistry on fingermark deposition and enhancement. The latter opens up a research area that has been under-explored to date but has the potential to improve our understanding of how fingermark secretions and enhancement reagents interact with paper substrates. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Taming tosyl azide: the development of a scalable continuous diazo transfer process.

    Science.gov (United States)

    Deadman, Benjamin J; O'Mahony, Rosella M; Lynch, Denis; Crowley, Daniel C; Collins, Stuart G; Maguire, Anita R

    2016-04-07

    Heat and shock sensitive tosyl azide was generated and used on demand in a telescoped diazo transfer process. Small quantities of tosyl azide were accessed in a 'one pot' batch procedure using shelf stable, readily available reagents. For large scale diazo transfer reactions tosyl azide was generated and used in a telescoped flow process, to mitigate the risks associated with handling potentially explosive reagents on scale. The in situ formed tosyl azide was used to rapidly perform diazo transfer to a range of acceptors, including β-ketoesters, β-ketoamides, malonate esters and β-ketosulfones. An effective in-line quench of sulfonyl azides was also developed, whereby a sacrificial acceptor molecule ensured complete consumption of any residual hazardous diazo transfer reagent. The telescoped diazo transfer process with in-line quenching was used to safely prepare over 21 g of an α-diazocarbonyl in >98% purity without any column chromatography.

  4. On-line pre-reduction of Se(VI) by thiourea for selenium speciation by hydride generation

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Jianhua [Department of Chemistry and the MOE Key Laboratory of Analytical Sciences, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005 (China); Wang Qiuquan [Department of Chemistry and the MOE Key Laboratory of Analytical Sciences, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005 (China)]. E-mail: qqwang@xmu.edu.cn; Ma Yuning [Department of Chemistry and the MOE Key Laboratory of Analytical Sciences, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005 (China); Yang Limin [Department of Chemistry and the MOE Key Laboratory of Analytical Sciences, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005 (China); Huang Benli [Department of Chemistry and the MOE Key Laboratory of Analytical Sciences, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, Fujian 361005 (China)

    2006-07-15

    In this study, thiourea (TU) was novelly developed as a reduction reagent for on-line pre-reduction of selenium(VI) before conventional hydride generation (HG) by KBH{sub 4}/NaOH-HCl. After TU on-line pre-reduction, the HG efficiency of Se(VI) has been greatly improved and because even higher than that of the same amount of Se(IV) obtained in the conventional HG system. The possible pre-reduction mechanism is discussed. The detection limit (DL) of selenate reaches 10 pg mL{sup -1} when using on-line TU pre-reduction followed by HG atomic fluorescence detection. When TU pre-reduction followed by HG is used as an interface between ion-pair high performance liquid chromatography and atomic fluorescence spectrometry, selenocystine, selenomethionine, selenite and selenate can be measured simultaneously and quantitatively. The DLs of these are 0.06, 0.08, 0.05 and 0.04 ng mL{sup -1}, respectively, and the relative standard deviations of 9 duplicate runs for all the 4 species are less than 5%. Furthermore, it was successfully applied to Se speciation analysis of cultured garlic samples, and validated by determination of total selenium and selenium species in certified reference material NIST 1946.

  5. Emprego de reagente em suspensão em sistema de injeção em fluxo: determinação espectrofotométrica de sulfato em águas naturais

    Directory of Open Access Journals (Sweden)

    Crnkovic Paula Manoel

    2002-01-01

    Full Text Available This paper presents an automatic procedure employing a reagent in the form of a slurry in a flow-injection system. The feasibility of the proposal is demonstrated by sulphate determination in water using the Barium Chloranilate method, which is based on the precipitation of barium sulphate. The release of a stoichiometric amount of highly colored chloranilic ions is monitored at 528 nm. The reaction is carried out in alcoholic medium in order to reduce the solubility of the reagent. A considerable improvement in the sensitivity is attained by adding ferric ions to the released chloranilic ions. An on-line filtration step to separate the excess reagent from the released chloranilic ions was necessary. In addition, a column containing a cation exchange resin was included in the manifold to remove potentially interfering ions. The proposed procedure is suitable for 30 determinations per hour and the relative standard deviation is less than 2%. The analytical curve is linear between 0.0 and 40 mg L-1 and the determination limit is about 2.0 mg L-1SO4(2-. Accuracy was confirmed by running several samples already analysed by a standard turbidimetric procedure.

  6. Microfluidic Sample Preparation for Diagnostic Cytopathology

    Science.gov (United States)

    Mach, Albert J.; Adeyiga, Oladunni B.; Di Carlo, Dino

    2014-01-01

    The cellular components of body fluids are routinely analyzed to identify disease and treatment approaches. While significant focus has been placed on developing cell analysis technologies, tools to automate the preparation of cellular specimens have been more limited, especially for body fluids beyond blood. Preparation steps include separating, concentrating, and exposing cells to reagents. Sample preparation continues to be routinely performed off-chip by technicians, preventing cell-based point-of-care diagnostics, increasing the cost of tests, and reducing the consistency of the final analysis following multiple manually-performed steps. Here, we review the assortment of biofluids for which suspended cells are analyzed, along with their characteristics and diagnostic value. We present an overview of the conventional sample preparation processes for cytological diagnosis. We finally discuss the challenges and opportunities in developing microfluidic devices for the purpose of automating or miniaturizing these processes, with particular emphases on preparing large or small volume samples, working with samples of high cellularity, automating multi-step processes, and obtaining high purity subpopulations of cells. We hope to convey the importance of and help identify new research directions addressing the vast biological and clinical applications in preparing and analyzing the array of available biological fluids. Successfully addressing the challenges described in this review can lead to inexpensive systems to improve diagnostic accuracy while simultaneously reducing overall systemic healthcare costs. PMID:23380972

  7. Methodology of comprehensive evaluation of the effectiveness and reliability of production lines of preparation of sea water for the cultivation of aquatic organisms

    Directory of Open Access Journals (Sweden)

    S. D. Ugryumova

    2016-01-01

    Full Text Available The factors affecting the efficiency and reliability of technical systems. Set stages of development and modernization of production lines that correspond to specific stages of evaluating the effectiveness and reliability. Considered several methods of definition of indicators of indicators of efficiency and reliability of the equipment in technological lines of fisheries sector: forecasting methods, structural methods, physical methods, logical-probability method (method by I.A. Ryabinin and topological method. Advantages and disadvantages, allowing you to work out the most suitable method, process lines preparation of sea water for the cultivation of aquatic organisms, connected in series. Modernized technological line of preparation of sea water for the cultivation of aquatic organisms differing from the typical line of seawater in hatcheries (Far East, as the presence of a large number of instrumentation: sensors, salinity and temperature; motomeru that continuously monitor turbidity in the range of 50÷100 EMF (30÷60 mg/1 by kaolin; signaling the flow sensors volume level of the filtrate and the backfill layer; analyzers of chemical composition of sea water; analyzers of suspended mechanical impurities; signaling sensors of acidity and oxygen content and replacement filters coarse, fine cleaning and auxiliary equipment. A program of comprehensive evaluation of the effectiveness and reliability of production lines, revealed that conducted the modernization of production line preparation of sea water for the cultivation of aquatic organisms has improved its efficiency by an average of 1.71% to reduce the amount of manual labor by 15.1%; control the process; provide the most rapid, efficient purification of sea water; reduce the cost of replacement filter media.

  8. Improvements to parallel plate flow chambers to reduce reagent and cellular requirements

    Directory of Open Access Journals (Sweden)

    Larson Richard S

    2001-09-01

    Full Text Available Abstract Background The parallel plate flow chamber has become a mainstay for examination of leukocytes under physiologic flow conditions. Several design modifications have occurred over the years, yet a comparison of these different designs has not been performed. In addition, the reagent requirements of many designs prohibit the study of rare leukocyte populations and require large amounts of reagents. Results In this study, we evaluate modifications to a newer parallel plate flow chamber design in comparison to the original parallel plate flow chamber described by Lawrence et al. We show that modifications in the chamber size, internal tubing diameters, injection valves, and a recirculation design may dramatically reduce the cellular and reagent requirements without altering measurements. Conclusions These modifications are simple and easily implemented so that study of rare leukocyte subsets using scarce or expensive reagents can occur.

  9. Preparation of 2H- and 3H-labelled carvone

    International Nuclear Information System (INIS)

    Banthorpe, D.V.; Brown, G.D.

    1989-01-01

    (-)-Carvone labelled with 2 H or 3 H at C-10 was prepared by two methods. The first, involving a reversible ene reaction yielded 10-deuteriocarvone with some substitution at other reactive centres. An improvement to this route involved the decompositon of an organozinc reagent of 10-chloro-carvone which gave a better yield of product substituted only at C-10. As a preliminary to a possible radioimmunoassay with the above material, four derivatives of carvone linked to bovine serum albumin were prepared. (author)

  10. The blocking reagent optimization for the magnetoelastic biosensor

    Science.gov (United States)

    Hu, Jiajia; Chai, Yating; Horikawa, Shin; Wikle, Howard C.; Wang, Feng'en; Du, Songtao; Chin, Bryan A.; Hu, Jing

    2015-06-01

    The wireless phage-based magnetoelastic (ME) biosensor has proven to be promising for real-time detection of pathogenic bacteria on fresh produces. The ME biosensor consists of a freestanding ME resonator as the signal transducer and filamentous phage as the biomolecular-recognition element, which can specifically bind to a pathogen of interest. Due to the Joule magnetostriction effect, the biosensors can be placed into mechanical resonance when subjected to a time-varying magnetic field alternating at the sensor's resonant frequency. Upon the attachment of the target pathogen, the mass of the biosensor increases, thereby decreasing its resonant frequency. This paper presents an investigation of blocking reagents immobilization for detecting Salmonella Typhimurium on fresh food surfaces. Three different blocking reagents (BSA, SuperBlock blocking buffer, and blocker BLOTTO) were used and compared. The optical microscope was used for bacterial cells binding observation. Student t-test was used to statistically analysis the experiment results. The results shows that SuperBlock blocking buffer and blocker BLOTTO have much better blocking performance than usually used BSA.

  11. Palladium-catalysed direct cross-coupling of secondary alkyllithium reagents

    NARCIS (Netherlands)

    Vila, Carlos; Giannerini, Massimo; Hornillos, Valentin; Fananas-Mastral, Martin; Feringa, Ben L.

    2014-01-01

    Palladium-catalysed cross-coupling of secondary C(sp(3)) organometallic reagents has been a long-standing challenge in organic synthesis, due to the problems associated with undesired isomerisation or the formation of reduction products. Based on our recently developed catalytic C-C bond formation

  12. 21 CFR 866.3370 - Mycobacterium tuberculosis immunofluorescent reagents.

    Science.gov (United States)

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents... used to identify Mycobacterium tuberculosis directly from clinical specimens. The identification aids...

  13. Resolution and isolation of enantiomers of (±)-isoxsuprine using thin silica gel layers impregnated with L-glutamic acid, comparison of separation of its diastereomers prepared with chiral derivatizing reagents having L-amino acids as chiral auxiliaries.

    Science.gov (United States)

    Bhushan, Ravi; Nagar, Hariom

    2015-03-01

    Thin silica gel layers impregnated with optically pure l-glutamic acid were used for direct resolution of enantiomers of (±)-isoxsuprine in their native form. Three chiral derivatizing reagents, based on DFDNB moiety, were synthesized having l-alanine, l-valine and S-benzyl-l-cysteine as chiral auxiliaries. These were used to prepare diastereomers under microwave irradiation and conventional heating. The diastereomers were separated by reversed-phase high-performance liquid chromatography on a C18 column with detection at 340 nm using gradient elution with mobile phase containing aqueous trifluoroacetic acid and acetonitrile in different compositions and by thin-layer chromatography (TLC) on reversed phase (RP) C18 plates. Diastereomers prepared with enantiomerically pure (+)-isoxsuprine were used as standards for the determination of the elution order of diastereomers of (±)-isoxsuprine. The elution order in the experimental study of RP-TLC and RP-HPLC supported the developed optimized structures of diastereomers based on density functional theory. The limit of detection was 0.1-0.09 µg/mL in TLC while it was in the range of 22-23 pg/mL in HPLC and 11-13 ng/mL in RP-TLC for each enantiomer. The conditions of derivatization and chromatographic separation were optimized. The method was validated for accuracy, precision, limit of detection and limit of quantification. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Stabilization of Transfected Cells Expressing Low-Incidence Blood Group Antigens: Novel Methods Facilitating Their Use as Reagent-Cells.

    Directory of Open Access Journals (Sweden)

    Cecilia González

    Full Text Available The identification of erythrocyte antibodies in the serum of patients rely on panels of human red blood cells (RBCs, which coexpress many antigens and are not easily available for low-incidence blood group phenotypes. These problems have been addressed by generating cell lines expressing unique blood group antigens, which may be used as an alternative to human RBCs. However, the use of cell lines implies several drawbacks, like the requirement of cell culture facilities and the high cost of cryopreservation. The application of cell stabilization methods could facilitate their use as reagent cells in clinical laboratories.We generated stably-transfected cells expressing low-incidence blood group antigens (Dia and Lua. High-expresser clones were used to assess the effect of TransFix® treatment and lyophilization as cell preservation methods. Cells were kept at 4°C and cell morphology, membrane permeability and antigenic properties were evaluated at several time-points after treatment.TransFix® addition to cell suspensions allows cell stabilization and proper antigen detection for at least 120 days, despite an increase in membrane permeability and a reduction in antigen expression levels. Lyophilized cells showed minor morphological changes and antigen expression levels were rather conserved at days 1, 15 and 120, indicating a high stability of the freeze-dried product. These stabilized cells have been proved to react specifically with human sera containing alloantibodies.Both stabilization methods allow long-term preservation of the transfected cells antigenic properties and may facilitate their distribution and use as reagent-cells expressing low-incidence antigens, overcoming the limited availability of such rare RBCs.

  15. Evaluation of nitrate quantification techniques for in-line analysis in drinking water

    International Nuclear Information System (INIS)

    Hernandez Alpizar, Laura; Coy Herrera, Ricardo

    2015-01-01

    The results of a study are presented to determine the potential use of four techniques for the quantification of nitrates in continuous sampling: ion chromatography, ultraviolet absorption spectrophotometry; one table equipment and two mini-spectrophotometers with continuous flow sample injection are used, one for measurements in the field of visible radiation and the other optimized for measurements of ultraviolet radiation absorption. Variables that are considered: reagent and accessory consumption, waste toxicity, analyte response, detection limit (LD), quantification limit (LC), linearity in the field of interest and sensitivity. Ultraviolet absorption detection spectro photometry with continuous flow sample injection is the best of the techniques for line analysis. The response has been between 0-10 mg / L linear, data recommended by WHO for the concentration of nitrates in drinking water. Low consumption of reagents and accessories is shown. This spectrophotometry without hazardous waste generated, has had LD 0.002 mg / L and LC 0.006 mg / L and an adequate sensitivity to respond rapidly to the concentration of the analyte without signal saturation. The desirable characteristics are fulfilled for an on-line analysis system. (author) [es

  16. The behavior of thiourea and flotation reagents in zinc electrowinning circuits

    Science.gov (United States)

    MacKinnon, D. J.; Dutrizac, J. E.; Brannen, J. M.; Hardy, D. J.

    1988-04-01

    The effect of thiourea and flotation reagents on the electrowinning of zinc from industrial electrolytes was studied, and all the compounds were found to reduce the zinc deposition current efficiency and to change the properties of the zinc deposits. The effectiveness of activated carbon, two-stage cementation, and hot acid leaching on the destruction/removal of the organic compounds also was addressed. Activated carbon pretreatment of thiourea-containing electrolytes restored the current efficiency for 1-hour zinc deposits to values comparable to those obtained for thiourea-free electrolytes. The activated carbon pretreatment, however, altered the deposit morphology and orientation, but produced a cyclic voltammogram similar to that of the thiourea-free solution. Two-stage cementation did not counteract the harmful effects of thiourea. Hot acid leaching destroyed the thiourea but generated large concentrations of ferrous ion that reduced the current efficiency. The ferrous concentrations, however, were readily controlled by KMnO4 or MnO2 oxidation. None of the treatment options (activated carbon, two-stage cementation, or hot acid leaching) was effective in controlling the flotation reagents, and their moderately harmful effect on zinc electrowinning persisted. Even low concentrations of these reagents polarized zinc deposition, and this resulted in a “glue-type” zinc deposit.

  17. Decontaminating reagents for radioactive systems

    International Nuclear Information System (INIS)

    Seddon, W.A.

    1982-01-01

    A decontaminating reagent composition has been developed comprising EDTA, citric acid, oxalic acid, and formic acid. Formic acid inhibits the decomposition of both EDTA and citric acid, and yields oxalic acid as a result of its own radiolysis. The invention includes the improvement of initially incorporating formic acid in the mixture and maintaining the presence of formic acid by at least one further addition

  18. The pyruvic acid analog 3-bromopyruvate interferes with the tetrazolium reagent MTS in the evaluation of cytotoxicity.

    Science.gov (United States)

    Ganapathy-Kanniappan, Shanmugasundaram; Geschwind, Jean-Francois H; Kunjithapatham, Rani; Buijs, Manon; Syed, Labiq H; Rao, Pramod P; Ota, Shinichi; Vali, Mustafa

    2010-04-01

    3-Bromopyruvate (3BrPA) is a pyruvate analog known for its alkylating property. Recently, several reports have documented the antiglycolytic and anticancer effects of 3BrPA and its potential for therapeutic applications. 3BrPA-mediated cytotoxicity has been evaluated in vitro by various methods including tetrazolium salt (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-2H-tetrazolium bromide)-based assays such as MTT, MTS, and so on. However, growing body of evidences has shown that tetrazolium reagent may interfere with the test compounds. In this study, we investigated whether the tetrazolium reagent interferes with the assessment of 3BrPA cytotoxicity. The results of the tetrazolium-based MTS assay were compared with 3 distinct cell viability detection methods, that is, Trypan Blue staining, ATP depletion, and Annexin V staining in 2 different cell lines, Vx-2 and HepG2. The MTS assay data showed false positive results by indicating increased cell viability at 1 mM and 2 mM 3BrPA whereas the other cell viability assays demonstrated that both Vx-2 and HepG2 cells are not viable at the same treatment conditions. In order to validate the direct interaction of 3BrPA with MTS reagent, we tested cell-free media incubated with different concentrations of 3BrPA. The results of cell-free media showed an increase in absorbance in a dose-dependent manner confirming the interaction of MTS with 3BrPA. Thus, our data clearly demonstrate that 3BrPA interferes with the accuracy of MTS-based cytotoxicity evaluation. Hence, we suggest that employing multiple methods of biochemical as well as morphological cytotoxicity assays is critical to evaluate 3BrPA-mediated cell death.

  19. Specific Reagent for Cr(III): Imaging Cellular Uptake of Cr(III) in Hct116 Cells and Theoretical Rationalization.

    Science.gov (United States)

    Ali, Firoj; Saha, Sukdeb; Maity, Arunava; Taye, Nandaraj; Si, Mrinal Kanti; Suresh, E; Ganguly, Bishwajit; Chattopadhyay, Samit; Das, Amitava

    2015-10-15

    A new rhodamine-based reagent (L1), trapped inside the micellar structure of biologically benign Triton-X 100, could be used for specific recognition of Cr(III) in aqueous buffer medium having physiological pH. This visible light excitable reagent on selective binding to Cr(III) resulted in a strong fluorescence turn-on response with a maximum at ∼583 nm and tail of that luminescence band extended until 650 nm, an optical response that is desired for avoiding the cellular autofluorescence. Interference studies confirm that other metal ions do not interfere with the detection process of Cr(III) in aqueous buffer medium having pH 7.2. To examine the nature of binding of Cr(III) to L1, various spectroscopic studies are performed with the model reagent L2, which tend to support Cr(III)-η(2)-olefin π-interactions involving two olefin bonds in molecular probe L1. Computational studies are also performed with another model reagent LM to examine the possibility of such Cr(III)-η(2)-olefin π-interactions. Presumably, polar functional groups of the model reagent LM upon coordination to the Cr(III) center effectively reduce the formal charge on the metal ion and this is further substantiated by results of the theoretical studies. This assembly is found to be cell membrane permeable and shows insignificant toxicity toward live colon cancer cells (Hct116). Confocal laser scanning microscopic studies further revealed that the reagent L1 could be used as an imaging reagent for detection of cellular uptake of Cr(III) in pure aqueous buffer medium by Hct116 cells. Examples of a specific reagent for paramagnetic Cr(III) with luminescence ON response are scanty in the contemporary literature. This ligand design helped us in achieving the turn on response by utilizing the conversion from spirolactam to an acyclic xanthene form on coordination to Cr(III).

  20. Exploring the Potential for Using Inexpensive Natural Reagents Extracted from Plants to Teach Chemical Analysis

    Science.gov (United States)

    Hartwell, Supaporn Kradtap

    2012-01-01

    A number of scientific articles report on the use of natural extracts from plants as chemical reagents, where the main objective is to present the scientific applications of those natural plant extracts. The author suggests that natural reagents extracted from plants can be used as alternative low cost tools in teaching chemical analysis,…

  1. Preparation of Metal Nanoparticles via Sonochemical Reduction

    OpenAIRE

    Saura Puig, Oriol

    2011-01-01

    Pure nickel, copper and zinc nanoparticles were prepared from chlorides of these elements using ultrasound with three different reducing agents (zinc, aluminum and magnesium). In the second part, syntheses of nickel-copper alloy and nickel-zinc using ultrasound were investigated. The products were characterized by powder X-ray diffraction. The reaction parameters, such as sonification time, the amount of reagents and reaction conditions were modified to observe variations in...

  2. On-line maintenance PSA support at NPP Krsko

    International Nuclear Information System (INIS)

    Prosen, R.; Vrbanic, I.; Kastelan, M.

    2000-01-01

    In 1997 Krsko NPP initiated the on-line maintenance (OLM) practice. On-line maintenance constitutes of corrective activities, preventive activities, surveillance activities, tests and inspections, as well as calibrations and modifications, taking place during the normal power operations. The on-line maintenance is a multidisciplinary process consisting of activity specification, planning, and preparation and performing of the OLM activity of interest. The primary role of the PSA group is to assess from the r isk perspective , using the plant-specific NEK PSA model, system unavailability and the impact to the plant operational risk. The intent is to support planning of the on-line maintenance activities from the risk perspective. The risk evaluation of the OLM activities is based on the probability of core damage evaluation for the defined discrete plant configuration states, determined by the OLM activities. Within this application, the optimized, plant-specific PSA model is used on Risk Spectrum platform. To perform the risk assessment of the on-line maintenance activities, first the systems to be affected are defined based on the planned OLM activities. The next important step is the assessment of the planned work schedule. To define the final schedule, the co-ordination and optimizing the planned OLM activities needs activation of all participating departments, supported also from PSA group. The P3 (i.e. Primavera) planning tool system windows are defined for different systems and groups of systems, and the activities are sorted in particular weeks according to these windows. (author)

  3. Remotely controlled reagent feed system for mixed waste treatment Tank Farm

    International Nuclear Information System (INIS)

    Dennison, D.K.; Bowers, J.S.; Reed, R.K.

    1995-02-01

    LLNL has developed and installed a large-scale. remotely controlled, reagent feed system for use at its existing aqueous low-level radioactive and mixed waste treatment facility (Tank Farm). LLNL's Tank Farm is used to treat aqueous low-level and mixed wastes prior to vacuum filtration and to remove the hazardous and radioactive components before it is discharged to the City of Livermore Water Reclamation Plant (LWRP) via the sanitary sewer in accordance with established limits. This reagent feed system was installed to improve operational safety and process efficiency by eliminating the need for manual handling of various reagents used in the aqueous waste treatment processes. This was done by installing a delivery system that is controlled either remotely or locally via a programmable logic controller (PLC). The system consists of a pumping station, four sets of piping to each of six 6,800-L (1,800-gal) treatment tanks, air-actuated discharge valves at each tank, a pH/temperature probe at each tank, and the PLC-based control and monitoring system. During operation, the reagents are slowly added to the tanks in a preprogrammed and controlled manner while the pH, temperature, and liquid level are continuously monitored by the PLC. This paper presents the purpose of this reagent feed system, provides background related to LLNL's low-level/mixed waste treatment processes, describes the major system components, outlines system operation, and discusses current status and plans

  4. In situ generation of the Ohira-Bestmann Reagent from stable sulfonyl azide

    DEFF Research Database (Denmark)

    Jepsen, Tue Heesgaard; Kristensen, Jesper Langgaard

    2014-01-01

    We report an improved method for in situ generation of the Ohira-Bestmann reagent. Using the recently reported bench stable imidazole-1-sulfonyl azide as diazotransfer reagent, this new method represents a safe and scalable approach for the transformation of aldehydes into terminal alkynes...

  5. Construction of a Liposome Dialyzer for preparation of high-value, small-volume liposome formulations

    OpenAIRE

    Adamala, Katarzyna; Engelhart, Aaron E.; Kamat, Neha P.; Jin, Lin; Szostak, Jack W.

    2015-01-01

    The liposome dialyzer is a small-volume equilibrium dialysis device, built from commercially available materials, that is designed for rapid exchange of small volumes of an extraliposomal reagent pool against a liposome preparation. The dialyzer is prepared by modification of commercially available dialysis cartridges and consists of a reactor with two 300 µL chambers and a 1.56 cm2 dialysis surface area. The dialyzer is prepared in three stages: 1) disassembly of dialysis cartridges to obtai...

  6. Separation of V(V)-4-(2-pyridylazo)resorcinolato complex from a large excess reagent using an ODS cartridge for high-performance liquid chromatography.

    Science.gov (United States)

    Takahashi, Toru; Kaneko, Emiko; Yotsuyanagi, Takao

    2006-12-01

    A selective off-line preconcentration technique for the V(V) complex with 4-(2-pyridylazo)resorcinol has been developed and successfully applied to the determination of V(V) in an air-borne sample. The target complex was separated from excess reagent using an ODS cartridge and water as the eluent. The complex was then concentrated on another ODS cartridge using tetrabutylammonium bromide and eluted with methanol; the eluate was applied to a one-drop concentration/HPLC. A detection limit as low as (6.05 +/- 0.82)x 10(-11) M (5 ppt) was achieved.

  7. 21 CFR 866.3250 - Erysipelothrix rhusiopathiae serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3250... Erysipelothrix rhusiopathiae from cultured isolates derived from clinical specimens. The identification aids in...

  8. 21 CFR 866.3270 - Flavobacterium spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3270.... from cultured isolates derived from clinical specimens. The identification aids in the diagnosis of...

  9. 21 CFR 866.3320 - Histoplasma capsulatum serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3320... capsulatum from clinical specimens or cultured isolates derived from clinical specimens. The identification...

  10. Assessing and preparing a pipeline for in line inspection

    Energy Technology Data Exchange (ETDEWEB)

    Payne, Larry [T.D. Williamson Inc., Tulsa, OK (United States)

    2003-07-01

    In today's pipeline environment, operators around the world face new and emerging state and federal regulations requiring validation of their pipelines' integrity. In line inspection, or smart pigging, is generally the preferred methodology used to investigate metal loss and corrosion in pipelines. Although many pipelines can accommodate smart pigging, there are many pipelines that cannot, for various reasons. Those reasons can vary from not having pig launchers and receivers installed on the line to impassable bends or restrictions and general cleanliness of the pipeline itself. Pipeline cleanliness, more times than not, is one of the main reasons for inaccurate in line inspection data gathering or failed smart pig runs. (author)

  11. A community standard format for the representation of protein affinity reagents

    DEFF Research Database (Denmark)

    Gloriam, David Erik Immanuel; Orchard, Sandra; Bertinetti, Daniela

    2010-01-01

    Protein affinity reagents (PARs), most commonly antibodies, are essential reagents for protein characterization in basic research, biotechnology, and diagnostics as well as the fastest growing class of therapeutics. Large numbers of PARs are available commercially; however, their quality is often...... that facilitates easy comparison of their cost and quality. However, in contrast to, for example, nucleotide databases among which data are synchronized between the major data providers, current PAR producers, quality control centers, and commercial companies all use incompatible formats, hindering data exchange....... Here we propose Proteomics Standards Initiative (PSI)-PAR as a global community standard format for the representation and exchange of protein affinity reagent data. The PSI-PAR format is maintained by the Human Proteome Organisation PSI and was developed within the context of Proteome...

  12. Study on LOMI decontamination technology

    International Nuclear Information System (INIS)

    Huang Fuduan; Yu Degui; Lu Jingju; Xie Yinyan

    1993-10-01

    The results of decontamination technique of Low-Oxidation-State Metal-Ion (LOMI) reagents developed from 1986 to 1991 in the laboratory are introduced. The experiments included preparation of LOMI reagents, de-filming efficiency, corrosion behavior of typical alloys, decontamination factors of reagents for contaminated materials and components have proved that the NP/LOMI decontamination method and treatment technique of waste water are feasible and have some advantages. The preparation of LOMI reagent with low concentration of formic acid by reduced pressure distilling technique and the utilization ratio of vanadium reached to 95% by second electrolysis are the main contributions of the study to the decontamination technique

  13. 21 CFR 866.3165 - Cryptococcus neoformans serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3165... clinical specimens or from cultured isolates derived from clinical specimens. The identification aids in...

  14. 21 CFR 866.3140 - Corynebacterium spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3140.... from clinical specimens. The identification aids in the diagnosis of disease caused by bacteria...

  15. 21 CFR 866.3110 - Campylobacter fetus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3110 Campylobacter... clinical specimens or cultured isolates derived from clinical specimens. The identification aids in the...

  16. 21 CFR 866.3340 - Klebsiella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3340 Klebsiella... from clinical specimens. The identification aids in the diagnosis of diseases caused by bacteria...

  17. 21 CFR 866.3930 - Vibrio cholerae serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3930 Vibrio... from cultured isolates derived from clinical specimens. The identification aids in the diagnosis of...

  18. 21 CFR 866.3010 - Acinetobacter calcoaceticus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3010... this bacterium from cultured isolates derived from clinical specimens. The identification aids in the...

  19. A Snippet of Grignard Reagent's History

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 18; Issue 8. A Snippet of Grignard Reagent's History. Sujan Singh Dua. Classroom Volume 18 Issue 8 August 2013 pp 777-780. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/018/08/0777-0780. Keywords.

  20. Unattended reaction monitoring using an automated microfluidic sampler and on-line liquid chromatography.

    Science.gov (United States)

    Patel, Darshan C; Lyu, Yaqi Fara; Gandarilla, Jorge; Doherty, Steve

    2018-04-03

    In-process sampling and analysis is an important aspect of monitoring kinetic profiles and impurity formation or rejection, both in development and during commercial manufacturing. In pharmaceutical process development, the technology of choice for a substantial portion of this analysis is high-performance liquid chromatography (HPLC). Traditionally, the sample extraction and preparation for reaction characterization have been performed manually. This can be time consuming, laborious, and impractical for long processes. Depending on the complexity of the sample preparation, there can be variability introduced by different analysts, and in some cases, the integrity of the sample can be compromised during handling. While there are commercial instruments available for on-line monitoring with HPLC, they lack capabilities in many key areas. Some do not provide integration of the sampling and analysis, while others afford limited flexibility in sample preparation. The current offerings provide a limited number of unit operations available for sample processing and no option for workflow customizability. This work describes development of a microfluidic automated program (MAP) which fully automates the sample extraction, manipulation, and on-line LC analysis. The flexible system is controlled using an intuitive Microsoft Excel based user interface. The autonomous system is capable of unattended reaction monitoring that allows flexible unit operations and workflow customization to enable complex operations and on-line sample preparation. The automated system is shown to offer advantages over manual approaches in key areas while providing consistent and reproducible in-process data. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Preparation of Silver Nano-Particles and Use as a Material for Water Sterilization

    Directory of Open Access Journals (Sweden)

    Tran Hong Con

    2011-01-01

    Full Text Available High dispersed nanodimensional silver metal (nanosilver solution of concentration ranging from 40 to 400 mg/L was prepared from silver nitrate in water media with and without dispersing reagent. The reduction process was initiated by ammonium hydroxide and glucose was used as a reductive reagent. The nanosilver solution was characterized by color changing from light-yellow to yellow, brown, red-brown, brown-green, dark-green, blue, dark-blue and those were depending on silver concentration and dimension of silver metal particles. The nanosilver solution was possibly used as a direct sterilizing reagent or coating on calcinated laterite grains to create sterilizing material in bacterial removing filter. Direct sterilization ability of nanosilver solution and nanosilver coated material was investigated. The results showed that with 10 ppb nanosilver in supplied water, all bacteria will be removed within 25–30 min. 10 mm thick layer of silica gel or 20 mm of calcinated laterite coated nanosilver could remove all bacteria in water flowed though with maximum flow rate of 100 L.m2/min. Moreover, sterilizing material was nontoxic and applicable for drinking water production.

  2. Improved Procedure for Preparation of Covalently Bonded Cellulose Tris-phenylcarbamate Chiral Stationary Phases

    Institute of Scientific and Technical Information of China (English)

    秦峰; 陈小明; 刘月启; 邹汉法; 王俊德

    2005-01-01

    The classical method for preparation of covalently boned cellulose derivative chiral stationary phases (CSP) with diisocyanate as spacer was improved. Diisocyanate was firstly allowed to react with 3-aminopropyltriethoxysilane, and the resulting product was then applied as the spacer reagent to immobilize cellulose derivatives onto silica gel. Influences of the amount and the length of the spacer on the optical resolution ability of the CSP were investigated. Comparing improved procedure to classical diisocyanate method, the cross-linking between the glucose units of the cellulose derivatives was avoided to the most extent. With the improved procedure, regio-nonselective ways could be adooted to prepare covalently bonded CSP, which showed an advantage for the rapid preparation.

  3. 21 CFR 866.3850 - Trichinella spiralis serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3850... devices that consist of antigens and antisera used in serological tests to identify antibodies to...

  4. 21 CFR 866.3680 - Sporothrix schenckii serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3680... devices that consist of antigens and antisera used in serological tests to identify antibodies to...

  5. 21 CFR 866.3400 - Parainfluenza virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3400 Parainfluenza... that consist of antigens and antisera used in serological tests to identify antibodies to parainfluenza...

  6. 21 CFR 866.3040 - Aspergillus spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3040 Aspergillus... consist of antigens and antisera used in various serological tests to identify antibodies to Aspergillus...

  7. 21 CFR 866.3125 - Citrobacter spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3125 Citrobacter... isolates derived from clinical specimens. The identification aids in the diagnosis of disease caused by...

  8. 21 CFR 866.3740 - Streptococcus spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3740 Streptococcus... derived from clinical specimens. The identification aids in the diagnosis of diseases caused by bacteria...

  9. 21 CFR 866.3065 - Bordetella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3065 Bordetella... serological tests to identify Bordetella spp. from cultured isolates or directly from clinical specimens. The...

  10. Purification of flavonoids from licorice using an off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method.

    Science.gov (United States)

    Fan, Yunpeng; Fu, Yanhui; Fu, Qing; Cai, Jianfeng; Xin, Huaxia; Dai, Mei; Jin, Yu

    2016-07-01

    An orthogonal (71.9%) off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self-made Click TE-Cys (60 μm) solid-phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE-Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co-eluted in the first dimension were selected for further purification using reversed-phase liquid chromatography. Multiple compounds could be isolated from one normal-phase fraction and some compounds with bad resolution in one-dimensional liquid chromatography could be prepared in this two-dimensional system owing to the orthogonal separation. Moreover, this two-dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off-line two-dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. 21 CFR 866.3145 - Coxsackievirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3145... fluorescent dye that are used to identify coxsackievirus from clinical specimens or from tissue culture isolates derived from clinical specimens. The identification aids in the diagnosis of coxsackievirus...

  12. USE OF FENTON'S REAGENT AS A DISINFECTANT

    Science.gov (United States)

    Combined sewage samples obtained from a wastewater treatment facility were disinfected by the Fenton's Reagent of several different compositions. The pre-settled samples contained both suspended solids (SS) and dissolved organic carbon (DOC) at concentrations of 28 and 290 mg/L,...

  13. Effects of coal composition and flotation reagents on the water resistance of binderless briquettes

    Energy Technology Data Exchange (ETDEWEB)

    Motaung, S.R.; Mangena, S.J.; de Korte, G.J. [Syngas & Coal Technology, Sasolburg (South Africa)

    2007-10-15

    The difference in the physical properties, particularly the water resistance or wet strength, of the binderless coal briquettes produced from flotation feed and concentrate was investigated using six bituminous coals from two collieries in the Witbank Coalfield. The coal samples were analyzed for their proximate, petrographic, and mineralogical properties. The presence, in the flotation concentrates, of the reagents used during the froth flotation process was also investigated using gas chromatography. Pillow-shaped binderless briquettes were produced from coal samples at various moisture contents and a pressure of approximately 17 MPA using a Komarek B-100A double-roll press. The briquettes were tested for some physical properties (i.e., dry- and wet-compressive strengths), which were thereafter compared with the properties determined for the coal samples. The binderless briquettes produced from the flotation concentrates were more water-resistant than those produced from the flotation feed. The flotation feed and concentrates of the coals tested were found to have similar petrographic properties. As expected, the ash and kaolinite contents were found to be lower in the flotation concentrates than in the flotation feed. Flotation reagents were detected in the flotation concentrates from both collieries. From the results obtained it is concluded that the increased water resistance of the binderless briquettes produced from flotation concentrates of the coals tested is due to a combination of the fineness of the coal particles, assisted by the amount of reactive macerals (most particularly vitrinite) with the lower ash and kaolinite contents, together with the presence of the flotation reagents, particularly the collector, in the flotation concentrate.

  14. A highly efficient dual-diazonium reagent for protein crosslinking and construction of a virus-based gel.

    Science.gov (United States)

    Ma, Dejun; Zhang, Jie; Zhang, Changyu; Men, Yuwen; Sun, Hongyan; Li, Lu-Yuan; Yi, Long; Xi, Zhen

    2018-05-09

    A new bench-stable reagent with double diazonium sites was designed and synthesized for protein crosslinking. Based on the highly efficient diazonium-Tyr coupling reaction, a direct mixture of the reagent and tobacco mosaic virus led to the formation of a new hydrogel, which could be degraded by chemicals and could be used to encapsulate small molecules for sustained release. Because plant viruses exhibit many chemical characteristics like protein labelling and nucleic acid packaging, the virus-based hydrogel will have large chemical space for further functionalization. Besides, this dual-diazonium reagent should be a generally useful crosslinker for chemical biology and biomaterials.

  15. Research Progress of Microfluidic Chips Preparation and its Optical Element

    Directory of Open Access Journals (Sweden)

    Feng WANG

    2014-03-01

    Full Text Available Microfluidic technology is the emerging technologies in researching fluid channel and related applications in the micro and nano-scale space. Microfluidic chip is a new miniaturized rapid analysis platform by microfluidic technology, it has many characteristics such as liquid flow control, minimal reagent consumption, rapid analysis, which is widely used in physics, chemistry, biology, and engineering science and other fields, it has strong interdisciplinary. This paper mainly discusses research progress of materials used for microfluidic chips and the devices based on microfluidic technology, including microfluidic chip, microfluidic optical devices, microfluidic laser preparation, microfluidic chip applications, focusing on the quasi-molecular laser processing technology and femtosecond laser processing technology in the microfluidic devices preparation, and make development prospects for it.

  16. POLYNUCLEAR AROMATIC HYDROCARBON (PAH) RELEASE FROM SOIL DURING TREATMENT WITH FENTON'S REAGENT

    Science.gov (United States)

    Fenton's Reagent was used to treat soil from a wood-treating site in southeastern Ohio which had been contaminated with creosote. Slurries, consisting of 10 µg of contaminated soil and 30 mL water were treated with 40 mL of Fenton's Reagent (1:1 of 30% H2O2 ...

  17. 21 CFR 866.3870 - Trypanosoma spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3870 Trypanosoma... consist of antigens and antisera used in serological tests to identify antibodies to Trypanosoma spp. in...

  18. 21 CFR 866.3630 - Serratia spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3630 Serratia spp... antigens and antisera used in serological tests to identify Serratia spp. from cultured isolates. The...

  19. 21 CFR 866.3660 - Shigella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3660 Shigella spp...), used in serological tests to identify Shigella spp. from cultured isolates. The identification aids in...

  20. 21 CFR 866.3330 - Influenza virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3330 Influenza... consist of antigens and antisera used in serological tests to identify antibodies to influenza in serum...

  1. 21 CFR 866.3035 - Arizona spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3035 Arizona spp... antisera and antigens used to identify Arizona spp. in cultured isolates derived from clinical specimens...

  2. 21 CFR 866.3380 - Mumps virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3380 Mumps virus... serological tests to identify mumps viruses from tissue culture isolates derived from clinical specimens. The...

  3. Software for on-line experiments

    International Nuclear Information System (INIS)

    Ivanchenko, I.M.

    1981-01-01

    A review of nowadays development state of software of on-line electron experiments is presented. The principles of organization of real time systems on second generation computer base are considered. The following methods for projections search are considered: combinator methods, global methods, methods of tracking, methods of a supporting band. The following methods for determining parameter estimates based on the Lorentz equation are analysed: analytical simulation of trajectories, determination of parameters by the iterative method using the technique of calculation of recycled integrals, multidimensional statistical analysis. For the purpose of successful usage and development of software the technique of selfdocumented programs is created and the computer is applied for preparing, revising and circulation of external descriptions which as program complexes are constructed according to the hierarchical principle [ru

  4. Dispersion and deagglomerat1on of nano-SiO2 particles with a silane modification reagent in supercritical CO2

    Directory of Open Access Journals (Sweden)

    Stojanović Dušica B.

    2007-01-01

    Full Text Available The supercritical CO2 method was used in order to perform deagglomeration and improve the dispersion of nano-SiO2 particles. γ-Met-hacryloxypropyltrimethoxysilane was used as the surface modification reagent. The conventional method for coating nano-SiO2 particles was used as the comparison method. Considerable improvement of the dispersion and deagglomeration was found using supercritical CO2. Analysis of the TEM micrographs and DLS results showed the reduction of the average size of the agglomerates with the silane coupling reagent. Thermogravimetric analysis (TGA showed that the particles treated in super­critical CO2 were more thermally stable than particles treated by conventional method. Encapsulation of several particles coated with the silane coupling reagent was observed in certain parts of the primary particles. A chemical reaction takes place between the modification reagent, MEMO silane, and active hydroxyl groups on the surface of the nano-SiO2 particles. A larger quantity of MEMO silane reacted using the con­ventional method instead of the supercritical method. On the other hand, the reacted silane molecules were better arranged around the particle surface in the supercritical method because of the formation of covalent or self-assembled structures. Polycondensed structures were preferentially obtained in the conventional method. This was achieved by using supercritical CO2, which has a high solvating power such as organic solvents and physical properties (low viscosity, low surface tension and high diffusion coefficient similar to gases on the other side. These properties enable the sufficient and uniform wettability of nano-SiO2 particle surfaces. These results are important for obtaining nanofillers with improved dispersion and polymer wettability. Such nanofillers can be used to obtain composite materials with considerably improved mechanical characteristics.

  5. Functions of chalcogenide electrodes in solutions of complexing reagents and interfering ions

    International Nuclear Information System (INIS)

    Kiyanskij, V.V.

    1990-01-01

    The possibility to modify chalcogenide electrodes and their behaviour in solutions of complexing reagents for the development of new methods of potentiometric titration has been studied. It is shown that complexing reagents (EDTA, cupferron, 8-hydroxyquinoline, sodium dithiocarbaminate) and Cu(2), Hg(2) produce a strong effect on the functions of Ag, Cu, Cd, Pb - selective electrodes, which is used for titration of potential-determining and non-potential-determining ions ions (Sr 2+ , La 3+ etc.) and also for modification of sulfide-selecting electrode. A method of potentiometric titration of sulfates and chlorides with modified Cd- and Ag-selective electrodes is suggested

  6. Oxytetracycline as a new analytical reagent for the spectrophotometric determination of boron

    Energy Technology Data Exchange (ETDEWEB)

    Narayana, G L

    1984-05-01

    Oxytetracycline hydrochloride, Terramycin, is introduced as a new reagent for the spectrophotometric determination of trace quantities of boron in concentrated sulphuric acid medium. The reagent has an absorption maximum at 430 nm, and that of the boron complex at 520 nm. The colored system conformed to Beer's law between 2 and 10 ..mu..g of boron at 520 nm. The molar absorptivity calculated on the basis of boron is 10,800 1 mol/sup -1/ cm/sup -1/. The composition of the complex has been shown to be 1:1 both by the slope ratio and molar ratio methods. 16 references.

  7. Oxytetracycline as a new analytical reagent for the spectrophotometric determination of boron

    International Nuclear Information System (INIS)

    Narayana, G.L.

    1984-01-01

    Oxytetracycline hydrochloride, Terramycin, is introduced as a new reagent for the spectrophotometric determination of trace quantities of boron in concentrated sulphuric acid medium. The reagent has an absorption maximum at 430 nm, and that of the boron complex at 520 nm. The coloured system conformed to Beer's law between 2 and 10 μg of boron at 520 nm. The molar absorptivity calculated on the basis of boron is 10,800 1 mol -1 cm -1 . The composition of the complex has been shown to be 1:1 both by the slope ratio and molar ratio methods. (author)

  8. Self-Sealed Bionic Long Microchannels with Thin Walls and Designable Nanoholes Prepared by Line-Contact Capillary-Force Assembly.

    Science.gov (United States)

    Lao, Zhao-Xin; Hu, Yan-Lei; Pan, Deng; Wang, Ren-Yan; Zhang, Chen-Chu; Ni, Jin-Cheng; Xu, Bing; Li, Jia-Wen; Wu, Dong; Chu, Jia-Ru

    2017-06-01

    Long microchannels with thin walls, small width, and nanoholes or irregular shaped microgaps, which are similar to capillaries or cancerous vessels, are urgently needed to simulate the physiological activities in human body. However, the fabrication of such channels remains challenging. Here, microchannels with designable holes are manufactured by combining laser printing with line-contact capillary-force assembly. Two microwalls are first printed by femtosecond laser direct-writing, and subsequently driven to collapse into a channel by the capillary force that arises in the evaporation of developer. The channel can remain stable in solvent due to the enhanced Van der Waals' force caused by the line-contact of microwalls. Microchannels with controllable nanoholes and almost arbitrary patterns can be fabricated without any bonding or multistep processes. As-prepared microchannels, with wall thicknesses less than 1 µm, widths less than 3 µm, lengths more than 1 mm, are comparable with human capillaries. In addition, the prepared channels also exhibit the ability to steer the flow of liquid without any external pump. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Modeling of On-Line Catalyst Addition Effects in a Short Contact Time Reactor

    National Research Council Canada - National Science Library

    Zerkle, David K; Allendorf, Mark Donald; Wolf, Markus; Deutschmann, Olaf

    2000-01-01

    ... operating ( on-line catalyst addition). Our simulations indicate that the fundamental behavior of the ethane SCTR prepared with catalyst added online is the result of coupled heterogeneous and homogeneous chemical processes...

  10. Sperm cell purification from mock forensic swabs using SOMAmer™ affinity reagents.

    Science.gov (United States)

    Katilius, Evaldas; Carmel, Andrew B; Koss, Heidi; O'Connell, Dan; Smith, Breanna C; Sanders, Glenn M; LaBerge, Greggory S

    2018-03-27

    We have demonstrated a proof of concept with affinity-based purification of sperm cells from mock forensic samples using SOMAmer™ reagents, DNA-based affinity reagents developed by SomaLogic, Inc. SOMAmer reagents were selected in vitro using whole-cell SELEX to bind specifically with intact, detergent-treated sperm cells. Successful separation of sperm from epithelial cells and their debris was demonstrated using buccal swabs with added semen. Primarily male DNA profiles were generated from sperm cells eluted from the types of cotton swabs typically used for rape kit evidence collection. The quality of sperm DNA isolated from samples purified using SOMAmers is comparable to existing commercially available differential extraction-based methods at higher sperm concentrations. This purification method is simple, offers relatively rapid (forensic casework. Copyright © 2018. Published by Elsevier B.V.

  11. A new achiral reagent for the incorporation of multiple amino groups into oligonucleotides

    DEFF Research Database (Denmark)

    Behrens, Carsten; Petersen, Kenneth H.; Egholm, Michael

    1995-01-01

    The synthesis of a new functionalized achiral linker reagent (10) for the incorporation of multiple primary amino groups into oligonucleotides is described. The linker reagent is compatible with conventional DNA-synthesis following the phosphoramidite methodology, and the linker can be incorporated...

  12. Inexpensive multiplexed library preparation for megabase-sized genomes.

    Directory of Open Access Journals (Sweden)

    Michael Baym

    Full Text Available Whole-genome sequencing has become an indispensible tool of modern biology. However, the cost of sample preparation relative to the cost of sequencing remains high, especially for small genomes where the former is dominant. Here we present a protocol for rapid and inexpensive preparation of hundreds of multiplexed genomic libraries for Illumina sequencing. By carrying out the Nextera tagmentation reaction in small volumes, replacing costly reagents with cheaper equivalents, and omitting unnecessary steps, we achieve a cost of library preparation of $8 per sample, approximately 6 times cheaper than the standard Nextera XT protocol. Furthermore, our procedure takes less than 5 hours for 96 samples. Several hundred samples can then be pooled on the same HiSeq lane via custom barcodes. Our method will be useful for re-sequencing of microbial or viral genomes, including those from evolution experiments, genetic screens, and environmental samples, as well as for other sequencing applications including large amplicon, open chromosome, artificial chromosomes, and RNA sequencing.

  13. Development of reagents for radioimmunoassay of: triiodothyronine, thyroxine and thyrotrophin; Desarrollo de reactivos para el radioinmunoanalisis de: triyodotironina, tiroxina y tirotrofina

    Energy Technology Data Exchange (ETDEWEB)

    Delgado S, B.; Lavalley E, C.; Ruiz J, A.; Garcia F, C.; Zamorano A, F

    1991-12-15

    The radioimmunoassay (RIA) of thyroid hormones it is the but it frequents of all the studies carried out by RIA in the laboratories of Nuclear Medicine, these essays are carried out with imported reagents. In the ININ the reagents and the necessary methodology have been developed for the triiodothyronine (T3), thyroxine (T4) and thyrotrophin (TSH). The good titles of the antibodies (Ac) primary for each hormone were of 1:4,000; 1:750 and 1:1,500. The used separation system was of double Ac with PEG to 10%, with titles of 1:10 for the second Ac of lamb. The specific activity for 125-I-T3 and 125-I-T4 oscillate between 850 at 900 {mu}Ci / {mu} g: being this of 90 {mu} Ci /{mu}g for TSH. To the first two hormones they were added 1-8 aniline naftalen sulfonic acid (ANS) to concentrations of 3 and 2 mg/ml respectively. As buffer for T3 and T4 it was used Tris-HCl pH 8.6 and PBS with normal serum of rabbit (SNC) for TSH. The standards got ready in buffer or free serum of thyroid hormones. The slope of the standard curves varied between -2.3 to -2.7 and the variation intra and inter assay among 4 to 10%. It is had at the moment in the ININ with standardized reagents for the RIA of T3, T4 and TSH, it is hoped to carry out tests in other laboratories and to establish the conditions of stability more appropriate to begin the preparation of pilot reagents. (Author)

  14. Effect of competing ions and causticization on the ammonia adsorption by a novel poly ligand exchanger (PLE) ammonia adsorption reagent.

    Science.gov (United States)

    Chen, Quanzhou; Zhou, Kanggen; Hu, Yuanjuan; Liu, Fang; Wang, Aihe

    2017-03-01

    In this paper, a poly ligand exchanger, Cu(II)-loaded chelating resin named ammonia adsorption reagent (AMAR), bearing the functional group of weak iminodiacetate acid, was prepared to efficiently remove ammonia from solutions. Batch adsorption equilibrium experiments were conducted under a range of conditions. The effects of pH on the removal of ammonia by AMAR were investigated at 25 °C. The copper loaded on the resin forms a complex with NH 3 in solution under alkaline condition. The effect of alkaline dosage (AD) on the ammonia adsorption was investigated. The maximum breakthrough bed volumes were obtained when the AD was set as 0.75 mmol OH - /mL. The higher AD did not guarantee the better ammonia removal efficiency due to the forming of Cu(OH) 2 precipitate between OH - in solutions and Cu(II) on the resin. The effect of competing ions on the adsorption breakthrough curve of virgin AMAR and causticized AMAR was also investigated. The results demonstrated that the existence of competing ions had a negative impact on the adsorption capacity for both virgin AMAR and causticized AMAR. After causticization, the AMAR was more resistant to the competing ions comparing with virgin AMAR. The bivalent Ca 2+ affects the ammonia adsorption more than does the monovalent Na + .

  15. Recyclable bio-reagent for rapid and selective extraction of contaminants from soil

    International Nuclear Information System (INIS)

    Lomasney, H.L.

    1997-01-01

    This Phase I Small Business Innovation Research program is confirming the effectiveness of a bio-reagent to cost-effectively and selectively extract a wide range of heavy metals and radionuclide contaminants from soil. This bioreagent solution, developed by ISOTRON reg-sign Corporation (New Orleans, LA), is flushed through the soil and recycled after flowing through an electrokinetic separation module, also developed by ISOTRON reg-sign. The process is ex situ, and the soil remains in its transport container through the decontamination process. The transport container can be a fiberglass box, or a bulk bag or open-quotes super sack.close quotes Rocks, vegetation, roots, etc. need not be removed. High clay content soils are accommodated. The process provides rapid injection of reagent solution, and when needed, sand is introduced to speed up the heap leach step. The concentrated waste form is eventually solidified. The bio-reagent is essentially a natural product, therefore any solubizer residual in soil is not expected to cause regulatory concern. The Phase I work will confirm the effectiveness of this bio-reagent on a wide range of contaminants, and the engineering parameters that are needed to carry out a full-scale demonstration of the process. ISOTRON reg-sign scientists will work with contaminated soil from Los Alamos National Laboratory. LANL is in the process of decontaminating and decommissioning more than 300 sites within its complex, many of which contain heavy metals or radionuclides; some are mixed wastes containing TCE, PCB, and metals

  16. Recyclable bio-reagent for rapid and selective extraction of contaminants from soil

    Energy Technology Data Exchange (ETDEWEB)

    Lomasney, H.L. [ISOTRON Corp., New Orleans, LA (United States)

    1997-10-01

    This Phase I Small Business Innovation Research program is confirming the effectiveness of a bio-reagent to cost-effectively and selectively extract a wide range of heavy metals and radionuclide contaminants from soil. This bioreagent solution, developed by ISOTRON{reg_sign} Corporation (New Orleans, LA), is flushed through the soil and recycled after flowing through an electrokinetic separation module, also developed by ISOTRON{reg_sign}. The process is ex situ, and the soil remains in its transport container through the decontamination process. The transport container can be a fiberglass box, or a bulk bag or {open_quotes}super sack.{close_quotes} Rocks, vegetation, roots, etc. need not be removed. High clay content soils are accommodated. The process provides rapid injection of reagent solution, and when needed, sand is introduced to speed up the heap leach step. The concentrated waste form is eventually solidified. The bio-reagent is essentially a natural product, therefore any solubizer residual in soil is not expected to cause regulatory concern. The Phase I work will confirm the effectiveness of this bio-reagent on a wide range of contaminants, and the engineering parameters that are needed to carry out a full-scale demonstration of the process. ISOTRON{reg_sign} scientists will work with contaminated soil from Los Alamos National Laboratory. LANL is in the process of decontaminating and decommissioning more than 300 sites within its complex, many of which contain heavy metals or radionuclides; some are mixed wastes containing TCE, PCB, and metals.

  17. Study and preparation of 99Tcm-GP kit for lung ventilation imaging

    International Nuclear Information System (INIS)

    Zhu Lin; Meng Fanmin; Zhang Jihong; Hong Tao; Liu Yunzhong; Liu Xiujie

    1997-01-01

    The preparation of the lyophilizing reagent, D-glucose-l-phosphate (GP) kit and the method of using this kit to label 99 Tc m to form 99 Tc m -GP for lung ventilation imaging at room temperature in a simple, rapid procedure are described. The stability of the lyophilizing reagent kit under various stock conditions is examined. The results show that all of the 99 Tc m -GP yields by the lyophilizing reagent kit are above 95% at 4 degree C (cold), 20-25 degree C (room temperature) and 40 degree C (oven) for 180, 90 and 3 days, respectively. The clinical practice indicates that in comparison with 99 Tc m -DTPA, 99 Tc m -GP has remarkable difference (P 99 Tc m -GP is an ideal radioaerosol for SPECT studies of lung ventilation. It has high alveolar deposition rate but low adhesion in the major airways compared to those of 99 Tc m -DTPA. 99 Tc m -GP also features prolonged pulmonary clearance time

  18. Effects of sh-reagents on rat hepatic aldehyde dehydrogenase activity

    Energy Technology Data Exchange (ETDEWEB)

    Konoplitskaya, K.L.; Kuz' mina, G.I.; Grigor' yeva, M.V.; Poznyakova, T.N.

    The liver serves as the primary organ for the oxidation of ingested ethanol via a pathway involving alcohol- and aldehyde dehydrogenase. In view of the problem of alcoholism, three enzymes are of particular interest in understanding the biochemical mechanism that may be involved in alcohol addiction and in the formulation of therapeutic approaches. While alcohol dehydrogenase has been studied in considerable detail, current attention is centered on aldehyde dehydrogenase. A comparative analysis of the effects of a series of SH-active reagents - tetraethylthiuram disulfide (TETD), 5,5-dithiobisnitrobenzoic acid (DTNB), p-chloromercurybenzoate (PCMB), and N-ethylmaleimide (NEM) - were tested for their effects on the activity of aldehyde dehydrogenase of the hepatic mitochondrial (isozymes I and II) and microsomal (isozyme II) fractions of outbred albino rats. DTNB was found to be inhibited by 100 and 50% mitochondrial isozymes I and II, respectively, and by 20%, the microsomal enzyme under the conditions employed. DTNB and NEM inhibited by 30 and 50% isozymes I and II of the mitochondria, but had no effect on the microsomal isozyme. 24 references, 3 figures.

  19. Polymeric reagents

    International Nuclear Information System (INIS)

    Bozkurt, C.

    1979-01-01

    The system polymer-bound triphenyl phosphine/carbon tetrachloride was used for preparation of 14 C-labelled organic compounds. 7- 14 C-benzyl chloride, 7- 14 C-benzoyl chloride and 7- 14 C-N-butyl benzamide have been prepared in this way. The reaction conditions were optimized using inactive compounds. Using the results of this optimization, radiochemical yields of 90% could be obtained for the first time for the preparation of 14 C-labelled alkyl chlorides and carboxylic acid chlorides from the corresponding alcohols and acids on the carrier. Polymer-bound triphenylphosphine was further studied as a catalyst for Beckmann rearrangement on the example of the rearrangement of cyclohexanoneoxime into epsilon-caprolactam. Yields exceeding 90% could be obtained with polymer-bound triphenylphosphine. However, regeneration of the catalyst could only be achieved by the already known method using trichlorosilane, in part also with methyldichlorosilane. Other reducing agents were unsuccessful in regenerating the catalyst. (G.G.)

  20. The hydrogen sulfide donor, Lawesson's reagent, prevents alendronate-induced gastric damage in rats

    International Nuclear Information System (INIS)

    Nicolau, L.A.D.; Silva, R.O.; Damasceno, S.R.B.; Carvalho, N.S.; Costa, N.R.D.; Aragão, K.S.; Barbosa, A.L.R.; Soares, P.M.G.; Souza, M.H.L.P.; Medeiros, J.V.R.

    2013-01-01

    Our objective was to investigate the protective effect of Lawesson's reagent, an H 2 S donor, against alendronate (ALD)-induced gastric damage in rats. Rats were pretreated with saline or Lawesson's reagent (3, 9, or 27 µmol/kg, po) once daily for 4 days. After 30 min, gastric damage was induced by ALD (30 mg/kg) administration by gavage. On the last day of treatment, the animals were killed 4 h after ALD administration. Gastric lesions were measured using a computer planimetry program, and gastric corpus pieces were assayed for malondialdehyde (MDA), glutathione (GSH), proinflammatory cytokines [tumor necrosis factor (TNF)-α and interleukin (IL)-1β], and myeloperoxidase (MPO). Other groups were pretreated with glibenclamide (5 mg/kg, ip) or with glibenclamide (5 mg/kg, ip)+diazoxide (3 mg/kg, ip). After 1 h, 27 µmol/kg Lawesson's reagent was administered. After 30 min, 30 mg/kg ALD was administered. ALD caused gastric damage (63.35±9.8 mm 2 ); increased levels of TNF-α, IL-1β, and MDA (2311±302.3 pg/mL, 901.9±106.2 pg/mL, 121.1±4.3 nmol/g, respectively); increased MPO activity (26.1±3.8 U/mg); and reduced GSH levels (180.3±21.9 µg/g). ALD also increased cystathionine-γ-lyase immunoreactivity in the gastric mucosa. Pretreatment with Lawesson's reagent (27 µmol/kg) attenuated ALD-mediated gastric damage (15.77±5.3 mm 2 ); reduced TNF-α, IL-1β, and MDA formation (1502±150.2 pg/mL, 632.3±43.4 pg/mL, 78.4±7.6 nmol/g, respectively); lowered MPO activity (11.7±2.8 U/mg); and increased the level of GSH in the gastric tissue (397.9±40.2 µg/g). Glibenclamide alone reversed the gastric protective effect of Lawesson's reagent. However, glibenclamide plus diazoxide did not alter the effects of Lawesson's reagent. Our results suggest that Lawesson's reagent plays a protective role against ALD-induced gastric damage through mechanisms that depend at least in part on activation of ATP-sensitive potassium (K ATP ) channels

  1. [Comparative measurement of urine specific gravity: reagent strips, refractometry and hydrometry].

    Science.gov (United States)

    Costa, Christian Elías; Bettendorff, Carolina; Bupo, Sol; Ayuso, Sandra; Vallejo, Graciela

    2010-06-01

    The urine specific gravity is commonly used in clinical practice to measure the renal concentration/dilution ability. Measurement can be performed by three methods: hydrometry, refractometry and reagent strips. To assess the accuracy of different methods to measure urine specific gravity. We analyzed 156 consecutive urine samples of pediatric patients during April and May 2007. Urine specific gravity was measured by hydrometry (UD), refractometry (RE) and reagent strips (TR), simultaneously. Urine osmolarity was considered as the gold standard and was measured by freezing point depression. Correlation between different methods was calculated by simple linear regression. A positive and acceptable correlation was found with osmolarity for the RE as for the UD (r= 0.81 and r= 0.86, respectively). The reagent strips presented low correlation (r= 0.46). Also, we found good correlation between measurements obtained by UD and RE (r= 0.89). Measurements obtained by TR, however, had bad correlation when compared to UD (r= 0.46). Higher values of specific gravity were observed when measured with RE with respect to UD. Reagent strips are not reliable for measuring urine specific gravity and should not be used as an usual test. However, hydrometry and refractometry are acceptable alternatives for measuring urine specific gravity, as long as the same method is used for follow-up.

  2. The preparation of magnetite from iron(III) and iron(II) salt solutions

    International Nuclear Information System (INIS)

    Segal, D.L.

    1980-10-01

    Methods are described for the preparation of magnetite from iron(III) and iron(II) salt solutions at temperatures between 295 to 373 K. The effect of the reagent concentration, a chelating agent and different alkali-metal cations on the formation of magnetite has been investigated. The magnetite samples have been examined by X-ray diffraction, transmission electron microscopy, adsorption of nitrogen, emission spectroscopy, X-ray photoelectron spectroscopy and by determination of the point of zero charge. A review of previous work on the preparation of magnetite in an aqueous environment is also included. This work is relevant to the corrosion processes which can occur in the water coolant circuits of nuclear reactors. (author)

  3. Metastatic non-small-cell lung cancer: consensus on pathology and molecular tests, first-line, second-line, and third-line therapy: 1st ESMO Consensus Conference in Lung Cancer; Lugano 2010

    DEFF Research Database (Denmark)

    Felip, E; Gridelli, C; Baas, P

    2011-01-01

    the conference, the expert panel prepared clinically relevant questions concerning five areas: early and locally advanced non-small-cell lung cancer (NSCLC), first-line metastatic NSCLC, second-/third-line NSCLC, NSCLC pathology and molecular testing, and small-cell lung cancer to be addressed through discussion......The 1st ESMO Consensus Conference on lung cancer was held in Lugano, Switzerland on 21 and 22 May 2010 with the participation of a multidisciplinary panel of leading professionals in pathology and molecular diagnostics, medical oncology, surgical oncology and radiation oncology. Before...... at the Consensus Conference. All relevant scientific literature for each question was reviewed in advance. During the Consensus Conference, the panel developed recommendations for each specific question. The consensus agreement on three of these areas: NSCLC pathology and molecular testing, the treatment of first-line...

  4. Measurement of dabigatran: previously demonstrated Hemoclot® Thrombin Inhibitor assay reagent instability on Sysmex CS-2100i is no longer an issue

    DEFF Research Database (Denmark)

    Comuth, Willemijn; Faaborg, Louise; Henriksen, Linda Østervig

    2017-01-01

    hours. Since the reagent composition was unchanged, the increased stability could be due to changed logistics by the supplier, with stock and transfer closer by. Previously demonstrated HTI reagent instability is no longer an issue at our laboratory. The reliability of results of clinical studies...

  5. Reagents Activity in a Copper Droplets / Post-Processing Slag Suspension

    OpenAIRE

    Wołczyński W.; Karwan-Baczewska J.; Najman K.; Bydałek A.W.

    2016-01-01

    The suspension of the copper droplets in the post-processing slag taken directly from the KGHM-Polska Miedź S.A. Factory (from the direct-to-blister technology as performed in the flash furnace) was subjected to the special treatment with the use of the one of the typical industrial reagent and with the complex reagent newly patented by the authors. This treatment was performed in the BOLMET S.A. Company in the semi-industrial conditions. The result of the CaCO3, and Na2CO3 chemicals influenc...

  6. Risk-based Strategy to Determine Testing Requirement for the Removal of Residual Process Reagents as Process-related Impurities in Bioprocesses.

    Science.gov (United States)

    Qiu, Jinshu; Li, Kim; Miller, Karen; Raghani, Anil

    2015-01-01

    The purpose of this article is to recommend a risk-based strategy for determining clearance testing requirements of the process reagents used in manufacturing biopharmaceutical products. The strategy takes account of four risk factors. Firstly, the process reagents are classified into two categories according to their safety profile and history of use: generally recognized as safe (GRAS) and potential safety concern (PSC) reagents. The clearance testing of GRAS reagents can be eliminated because of their safe use historically and process capability to remove these reagents. An estimated safety margin (Se) value, a ratio of the exposure limit to the estimated maximum reagent amount, is then used to evaluate the necessity for testing the PSC reagents at an early development stage. The Se value is calculated from two risk factors, the starting PSC reagent amount per maximum product dose (Me), and the exposure limit (Le). A worst-case scenario is assumed to estimate the Me value, that is common. The PSC reagent of interest is co-purified with the product and no clearance occurs throughout the entire purification process. No clearance testing is required for this PSC reagent if its Se value is ≥1; otherwise clearance testing is needed. Finally, the point of the process reagent introduction to the process is also considered in determining the necessity of the clearance testing for process reagents. How to use the measured safety margin as a criterion for determining PSC reagent testing at process characterization, process validation, and commercial production stages are also described. A large number of process reagents are used in the biopharmaceutical manufacturing to control the process performance. Clearance testing for all of the process reagents will be an enormous analytical task. In this article, a risk-based strategy is described to eliminate unnecessary clearance testing for majority of the process reagents using four risk factors. The risk factors included

  7. Comparative studies on extracts from Hericium erinaceus by different polarity reagents to gain higher antioxidant activities.

    Science.gov (United States)

    Jiang, Shengjuan; Wang, Yuliang; Zhang, Xiaolong

    2016-07-01

    Hericium erinaceus (H. erinaceus) is a source of exogenous antioxidants that has been traditionally used in China for the prevention and treatment of oxidative stress-associated disease. In the present study, the bioactive compounds of H. erinaceus were extracted with the following eight representative reagents: n-Hexane, xylene, chloroform, anhydrous ether, ethyl acetate, acetone, anhydrous ethanol and distilled water. The in vitro antioxidant activities were also evaluated. All of the extracted compounds exhibited reducing power and scavenging activity against 1-diphenyl-2-picrylhydrazyl (DPPH) and superoxide anion free radicals. In addition, the antioxidant capacities varied with the used chemical reagents and exhibited dose-dependent effects. Extracts from anhydrous ethanol, chloroform and acetone were capable of inhibiting lipid peroxidation. The anhydrous ethanol extracts were observed to have significant levels of antioxidant compounds since they had a strong reducing power, high scavenging rates against DPPH and superoxide anion-free radicals (>90%), and high inhibition rates on lipid peroxidation (>60%). The present study will provide reference data for the antioxidant applications of H. erinaceus in pharmaceutical use and disease prevention.

  8. Effect of disulfide and sulfhydryl reagents on abortive and productive elongation catalyzed by ''Escheridia coli'' RNA polymerase

    International Nuclear Information System (INIS)

    Radlowski, M.; Job, D.

    1994-01-01

    The effect of disulfide and sulfhydryl reagents on the rate of abortive and productive elongation has been studied using ''Escherichia coli'' RNA polymerase holoenzyme and poly[d(A-T)] as template. In the presence of UTP as a single substrate and UpA as a primer, the enzyme catalyzed efficiently the synthesis of the trinucleotide product UpApU. Incubation of RNA polymerase with 1 mM 2-mercaptoethanol resulted in a 5-fold increase of the rate of UpApU synthesis. In contrast, incubation of the enzyme with 1 mM 5,5'-dithio-bis(2-nitrobenzoic) acid resulted in a 6-fold decrease of the rate of abortive elongation. Determination of the steady state kinetic constants associated with UpApU synthesis disclosed that the disulfide and sulfhydryl reagents mainly affected the rate of UpApU release from the ternary transcription complexes and therefore influenced the stability of such complexes. (author). 15 refs, 1 fig., 1 tab

  9. Determination оf Optimum Constructive Parameters for Circulating-Reagent Regeneration Sector Apparatus

    Directory of Open Access Journals (Sweden)

    A. M. Sheiko

    2008-01-01

    Full Text Available On the basis of equation analysis for velocity distribution in near filter mudded zone optimal constructional parameters of sector apparatus for circulating-reagent well filter regeneration have been evaluated via angle ratio of forcing and section sectors and number of sectors. The method for determination of sector apparatus length of а selected pump that provides dissolution of mud formation in filter and near filter zone is proposed in the paper. The obtained data would promote upgrading of circulating-reagent water well regeneration technology and it permits to carry out high quality and even rehabilitation of pore space penetration along the full well filter length.

  10. Tetrameric DABCO™-Bromine: an Efficient and Versatile Reagent ...

    African Journals Online (AJOL)

    NJD

    Reagent for Bromination of Various Organic Compounds. Majid M. Heravi,a* ... aDepartment of Chemistry, School of Sciences, Azzahra University, Vanak, Tehran, Iran. bChemistry ... Synthesis of "-bromo ketones and nitriles has also been ...

  11. Anti-D reagents should be chosen accordingly to the prevalence of D variants in the obstetric population.

    Science.gov (United States)

    Lukacevic Krstic, Jelena; Dajak, Slavica; Bingulac-Popovic, Jasna; Dogic, Vesna; Mratinovic-Mikulandra, Jela

    2018-03-01

    Resolving ambiguous results of D antigen typing is crucial for appropriate and rational administration of anti-D immunoprophylaxis and transfusion practice in obstetric population. The aim of the study was to establish selection criteria of anti-D reagents for our population. A total of 12 689 samples from primiparous women in Split-Dalmatia County, Croatia, were typed for RhD antigen during the period of 5 years. Ambiguous results were submitted to additional serologic investigation and genotyping. RHD genotyping was performed by commercial genotyping kits (Ready Gene weak D ® and Ready gene CDE, Inno-Train, Kronberg, Germany). Relative frequencies and accompanying 95% confidence intervals were used to estimate the prevalence of variants. The prevalence of D variants was 0.42% (95% CI 0.31; 0.53). The most common partial D variant was D Va (RHD*05.05), with the prevalence of 0.08% (95% CI 0.03; 0.13). All weak D variants were weak D types 1, 2 and 3 (RHD*weak D type 1, RHD*weak D type 2, RHD*weak D type 3). Weak D samples were distinguishable from partial D in routine typing due to the difference in reactivity of partial D samples with clones D7B8 and RUM-1. Cell line RUM-1 gives weak or negative reactions with partial DVa category. The most common partial D variant in our population is DVa. It is recommended to use cell lines which do not strongly agglutinate DVa variant in routine RhD typing. The appropriate choice of reagents will enable the serology methods to recognize the cases in which RHD genotyping is required. © 2017 Wiley Periodicals, Inc.

  12. Sol-gel process preparation and evaluation of the analytical performances of an hydrazine specific chemical sensor; Preparation par procede sol-gel et evaluation des performances analytiques d`un capteur chimique specifique de l`hydrazine

    Energy Technology Data Exchange (ETDEWEB)

    Gojon, C

    1996-12-01

    The realisation of optical fibers active chemical collector to analyze hydrazine in line, in the spent fuel reprocessing process is the subject of this work. The p.dimethyl-amino-benzaldehyde has been chosen as reagent for its chemical and optical properties. 186 refs.

  13. High throughput screening method for identification of new lipofection reagents.

    Science.gov (United States)

    Regelin, A E; Fernholz, E; Krug, H F; Massing, U

    2001-08-01

    Lipofection, the transfer of genetic material into cells by means of cationic lipids, is of growing interest for in vitro and in vivo approaches. In order to identify ideal lipofection reagents in a HTS, we have developed an automated lipofection method for the transfer of reporter genes into cells and for determination of the lipofection results. The method has specifically been designed and optimized for 96-well microtiter plates and can successfully be carried out by a pipetting robot with accessory equipment. It consists of two separate parts: (1) pretransfection (preparation of liposomes, formation of lipoplexes, and lipoplex transfer to the cells) and (2) posttransfection (determination of the reporter enzyme activity and the protein content of the transfected cells). Individual steps of the lipofection method were specifically optimized - for example, lipoplex formation and incubation time as well as cell lysis, cell cultivating, and the reporter gene assay. The HTS method facilitates characterization of the transfection properties (efficiency and cytotoxicity) of large numbers of (cationic) lipids in various adherent cell types.

  14. Synthesis and study of biological behavior of radiopharmaceutical preparations on the base of specific to receptors compounds

    International Nuclear Information System (INIS)

    Bruskin, A.B.; Klement'eva, O.E.; Kodina, G.E.; Korsunskij, V.N.; Korshunov, V.B.; Slobodnyak, I.I.

    2005-01-01

    Aim of the present work is study of conditions radionuclide administration in modified biomolecules and study of its conjugation with tumor cells in vivo and in vitro. Octreotide labelling by the 111 In reactions in different buffer systems with yield ≥95 % were carried out. Demands making to quality of initial solution 111 In chloride for providing of radiochemical purity of the labelled compound were determined. Time of maximal accumulation of peptide by tumor cells has been defined. It is shown, that accumulation of control preparation 111 In-DTPA - in dependence on selected cell culture and experiment conditions - in 5-10 time lower, than accumulation of labeled peptide. Lyophilized forms of reagents providing one-stage opportunity of the preparation production at clinic conditions were obtained. The product is stable in laboratory animals blood serum. By the data of biological distribution the differential accumulation coefficients making up: tumor/blood -5-30; tumor-muscle - 2-10. The scintigraphic image of mouse malice's tumor was get

  15. 21 CFR 866.3240 - Equine encephalomyelitis virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents... these viruses. Equine encephalomyelitis viruses are transmitted to humans by the bite of insects, such...

  16. Chemical bonding and the equilibrium composition of Grignard reagents in ethereal solutions.

    Science.gov (United States)

    Henriques, André M; Barbosa, André G H

    2011-11-10

    A thorough analysis of the electronic structure and thermodynamic aspects of Grignard reagents and its associated equilibrium composition in ethereal solutions is performed. Considering methylmagnesium halides containing fluorine, chlorine, and bromine, we studied the neutral, charged, and radical species associated with their chemical equilibrium in solution. The ethereal solvents considered, tetrahydrofuran (THF) and ethyl ether (Et(2)O), were modeled using the polarizable continuum model (PCM) and also by explicit coordination to the Mg atoms in a cluster. The chemical bonding of the species that constitute the Grignard reagent is analyzed in detail with generalized valence bond (GVB) wave functions. Equilibrium constants were calculated with the DFT/M06 functional and GVB wave functions, yielding similar results. According to our calculations and existing kinetic and electrochemical evidence, the species R(•), R(-), (•)MgX, and RMgX(2)(-) must be present in low concentration in the equilibrium. We conclude that depending on the halogen, a different route must be followed to produce the relevant equilibrium species in each case. Chloride and bromide must preferably follow a "radical-based" pathway, and fluoride must follow a "carbanionic-based" pathway. These different mechanisms are contrasted against the available experimental results and are proven to be consistent with the existing thermodynamic data on the Grignard reagent equilibria.

  17. Simplified sample preparation method for protein identification by matrix-assisted laser desorption/ionization mass spectrometry: in-gel digestion on the probe surface

    DEFF Research Database (Denmark)

    Stensballe, A; Jensen, Ole Nørregaard

    2001-01-01

    /ionization-time of flight mass spectrometry (MALDI-TOF-MS) is used as the first protein screening method in many laboratories because of its inherent simplicity, mass accuracy, sensitivity and relatively high sample throughput. We present a simplified sample preparation method for MALDI-MS that enables in-gel digestion...... for protein identification similar to that obtained by the traditional protocols for in-gel digestion and MALDI peptide mass mapping of human proteins, i.e. approximately 60%. The overall performance of the novel on-probe digestion method is comparable with that of the standard in-gel sample preparation...... protocol while being less labour intensive and more cost-effective due to minimal consumption of reagents, enzymes and consumables. Preliminary data obtained on a MALDI quadrupole-TOF tandem mass spectrometer demonstrated the utility of the on-probe digestion protocol for peptide mass mapping and peptide...

  18. Desalting Protein Ions in Native Mass Spectrometry Using Supercharging Reagents

    Science.gov (United States)

    Cassou, Catherine A.; Williams, Evan R.

    2014-01-01

    Effects of the supercharging reagents m-NBA and sulfolane on sodium ion adduction to protein ions formed using native mass spectrometry were investigated. There is extensive sodium adduction on protein ions formed by electrospray ionization from aqueous solutions containing millimolar concentrations of NaCl, which can lower sensitivity by distributing the signal of a given charge state over multiple adducted ions and can reduce mass measuring accuracy for large proteins and non-covalent complexes for which individual adducts cannot be resolved. The average number of sodium ions adducted to the most abundant ion formed from ten small (8.6–29 kDa) proteins for which adducts can be resolved is reduced by 58% or 80% on average, respectively, when 1.5% m-NBA or 2.5% sulfolane are added to aqueous solutions containing sodium compared to without the supercharging reagent. Sulfolane is more effective than m-NBA at reducing sodium ion adduction and at preserving non-covalent protein-ligand and protein-protein interactions. Desalting with 2.5% sulfolane enables detection of several glycosylated forms of 79.7 kDa holo-transferrin and NADH bound to the 146 kDa homotetramer LDH, which are otherwise unresolved due to peak broadening from extensive sodium adduction. Although sulfolane is more effective than m-NBA at protein ion desalting, m-NBA reduces salt clusters at high m/z and can increase the signal-to-noise ratios of protein ions by reducing chemical noise. Desalting is likely a result of these supercharging reagents binding sodium ions in solution, thereby reducing the sodium available to adduct to protein ions. PMID:25133273

  19. 21 CFR 866.3480 - Respiratory syncytial virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3480... respiratory syncytial viruses from clinical specimens or from tissue culture isolates derived from clinical...

  20. A review of the kinetics of oxidation and reduction of sale-free reagents in the U/Pu separation process

    International Nuclear Information System (INIS)

    Li Sa; Ouyang Yinggen; Gao Yaobin

    2012-01-01

    Background: Recently, the most reductant widely used to partition plutonium from uranium in the Purex solvent extraction purification process have been salt-free reagents. Purpose: In order to determine the utility of sale-free reagents in the Purex solvent extraction process. Methods: The report is a review of the applications of sale-free reagents in the U/Pu separation process, such as hydroxylamine derivative, U(IV), aldehyde derivative, hydrazine, hydroxyl carbamide, derivative, hydroxamic acid and so on. Results: In this review, we have investigated and summarized the previous works covering the thermodynamics and dynamics behaviors to offer references for the future R and D works on the capability of salt-free reagents in the PUREX process and to indicate its applications. Conclusions: Acetohydroxamic acid and hydroxysemicarbazide have the capability of stripping trace amount plutonium of uranium in the future industrialization. (authors)

  1. Inactivation of Escherichia coli glycerol kinase by 5'-[p-(fluorosulfonyl)benzoyl]adenosine: protection by the hydrolyzed reagent

    International Nuclear Information System (INIS)

    Pettigrew, D.W.

    1987-01-01

    Incubation of Escherichia coli glycerol kinase with 5'-[p-(fluorosulfonyl)benzoyl]adenosine (FSO 2 BzAdo) at pH 8.0 and 25 0 C results in the loss of enzyme activity, which is not restored by the addition of β-mercaptoethanol or dithiothreitol. The FSO 2 BzAdo concentration dependence of the inactivation kinetics is described by a mechanism that includes the equilibrium binding of the reagent to the enzyme prior to a first-order inactivation reaction in addition to effects of reagent hydrolysis. The hydrolysis of the reagent has two effects on the observed kinetics. The first effect is deviation from pseudo-first-order kinetic behavior due to depletion of the reagent. The second effect is the novel protection of the enzyme from inactivation due to binding of the sulfonate hydrolysis product. Determinations of the reaction stoichiometry with 3 H-labeled FSO 2 BzAdo show that the inactivation is associated with the covalent incorporation of 1.08 mol of reagent/mol of enzyme subunit. Ligand protection experiments show that ATP, AMP, dAMP, NADH, 5'-adenylyl imidodiphosphate, and the sulfonate hydrolysis product of FSO 2 BzAdo provide protection from inactivation. The protection obtained with ATMP is not dependent on Mg 2+ . The results are consistent with modification by FSO 2 BzAdo of a single adenine nucleotide binding site per enzyme subunit

  2. A multiple-well method for immunohistochemical testing of many reagents on a single microscopic slide.

    Science.gov (United States)

    McKeever, P E; Letica, L H; Shakui, P; Averill, D R

    1988-09-01

    Multiple wells (M-wells) have been made over tissue sections on single microscopic slides to simultaneously localize binding specificity of many antibodies. More than 20 individual 4-microliter wells over tissue have been applied/slide, representing more than a 5-fold improvement in wells/slide and a 25-fold reduction in reagent volume over previous methods. More than 30 wells/slide have been applied over cellular monolayers. To produce the improvement, previous strategies of placing specimens into wells were changed to instead create wells over the specimen. We took advantage of the hydrophobic properties of paint to surround the wells and to segregate the various different primary antibodies. Segregation was complete on wells alternating with and without primary monoclonal antibody. The procedure accommodates both frozen and paraffin sections, yielding slides which last more than a year. After monoclonal antibody detection, standard histologic stains can be applied as counterstains. M-wells are suitable for localizing binding of multiple reagents or sample unknowns (polyclonal or monoclonal antibodies, hybridoma supernatants, body fluids, lectins) to either tissues or cells. Their small sample volume and large number of sample wells/slide could be particularly useful for early screening of hybridoma supernatants and for titration curves in immunohistochemistry (McKeever PE, Shakui P, Letica LH, Averill DR: J Histochem Cytochem 36:931, 1988).

  3. Small-scale extraction and radioiodination of human hormones for the substitution of imported radioimmunoassay reagents

    International Nuclear Information System (INIS)

    Gimbo, E.K.; Ribela, M.T.C.P.; Borghi, V.C.; Schwarz, I.; Morganti, L.; Araujo, E.A.; Bartolini, P.

    1988-01-01

    The methods for national production of radioimmunoassay reagents to substitute imported kits of: highly purified unlabelled hormones for radioiodination; 125 I-labelled hormones; and specific high titre antisera are presented. The extraction and purification of human growth hormone (hGH) and human luteinizing hormone (hGH) were done from human pituitaries. The 125 I-labelled hormones are obtained by stoichiometric methods. The 125 I-hGH, 125 I-hLH, I-hTSH and 125 I- h calcitonin were prepared and tested in internal and external quality control, in comparison with imported products. The parameters such as: maximum binding to specific antiserum (Bo), nonspecific binding (NSB), mean effective dose (ED 50), sensitivity and accuracy were evaluated. (M.C.K.) [pt

  4. Determination of dopamine in presence of ascorbic acid and uric acid using poly (Spands Reagent) modified carbon paste electrode

    Energy Technology Data Exchange (ETDEWEB)

    Veera Manohara Reddy, Y.; Prabhakara Rao, V.; Vijaya Bhaskar Reddy, A.; Lavanya, M.; Venu, M.; Lavanya, M.; Madhavi, G., E-mail: gmchem01@gmail.com

    2015-12-01

    In this paper, we have fabricated a modified carbon paste electrode (CPE) by electropolymerisation of spands reagent (SR) onto surface of CPE using cyclic voltammetry (CV). The developed electrode was abbreviated as poly(SR)/CPE and the surface morphology of the modified electrode was studied by using scanning electron microscopy (SEM). The developed electrode showed higher electrocatalytic properties towards the detection of dopamine (DA) in 0.1 M phosphate buffer solution (PBS) at pH 7.0. The effect of pH, scan rate, accumulation time and concentration of dopamine was studied at poly(SR)/CPE. The poly(SR)/CPE was successfully used as a sensor for the selective determination of DA in presence of ascorbic acid (AA) and uric acid (UA) without any interference. The poly(SR)/CPE showed a good detection limit of 0.7 μM over the linear dynamic range of 1.6 μM to 16 μM, which is extremely lower than the reported methods. The prepared poly(SR)/CPE exhibited good stability, high sensitivity, better reproducibility, low detection limit towards the determination of DA. The developed method was also applied for the determination of DA in real samples. - Highlights: • Electropolymerization of spands reagent was fabricated by cyclic voltammetry • The Poly (spands reagent) electrode shows excellent electrocatalytic activity for the detection of dopamine. • The detection limit for dopamine was found to be 0.7 μM. • The proposed method can be applied for DA in injection and human blood serum samples.

  5. Evaluation of a portable urinary pH meter and reagent strips.

    Science.gov (United States)

    De Coninck, Vincent; Keller, Etienne Xavier; Rodríguez-Monsalve, María; Haymann, Jean-Philippe; Doizi, Steeve; Traxer, Olivier

    2018-04-27

    To evaluate a portable electronic pH meter and to put its accuracy in perspective with reagent strips read by a layperson, a healthcare professional and an electronic reading device. Based on a pre-analysis on 20 patients, a sample size of 77 urine aliquots from healthy volunteers was necessary to obtain sufficient study power. Measurements of urinary pH were obtained by use of reagent strips, a portable pH meter and a laboratory pH meter (gold standard). Reagents strips were read by a professional experienced in interpreting strips, a layperson, and an electronic strip reader. The mean matched pair difference between measurement methods was analyzed by the paired t-test. The degree of correlation and agreement were evaluated by the Pearson's correlation coefficient and Bland-Altman plots, respectively. The mean matched pair difference between the gold standard and all other pH measurement methods was the smallest with the portable electronic pH meter (bias 0.01, 95% CI -0.07 to 0.08; p=0.89), followed by strips read by a professional (bias -0.09, 95% CI -0.21 to 0.02; p=0.10), layperson (bias -0.17, 95% CI -0.31 to -0.04; p=0.015) and electronic strip reader (bias -0.29, 95% CI -0.41 to -0.16; pmeter achieved the highest Pearson's correlation coefficient and narrowest 95% limits of agreement, followed by strip interpretation by a professional, the electronic strip reader and the layperson. In order to quantify the ability of pH measurement methods to correctly classify values within a predefined urinary pH target range, we performed classification tests for several stones. The portable electronic pH meter outperformed all other measurement methods for negative predictive values. Findings of the current study support that the portable electronic pH meter is a reliable pH measuring device. It seems to be more accurate compared to reagent strips readings.

  6. From Off-line to On-line Handwriting Recognition

    NARCIS (Netherlands)

    Lallican, P.; Viard-Gaudin, C.; Knerr, S.

    2004-01-01

    On-line handwriting includes more information on time order of the writing signal and on the dynamics of the writing process than off-line handwriting. Therefore, on-line recognition systems achieve higher recognition rates. This can be concluded from results reported in the literature, and has been

  7. Sol-gel process preparation and evaluation of the analytical performances of an hydrazine specific chemical sensor

    International Nuclear Information System (INIS)

    Gojon, C.

    1996-12-01

    The realisation of optical fibers active chemical collector to analyze hydrazine in line, in the spent fuel reprocessing process is the subject of this work. The p.dimethyl-amino-benzaldehyde has been chosen as reagent for its chemical and optical properties

  8. Identification of mimotopes of Mycobacterium leprae as potential diagnostic reagents

    Directory of Open Access Journals (Sweden)

    Alban Silvana M

    2013-01-01

    Full Text Available Abstract Background An early diagnostic test for detecting infection in leprosy is fundamental for reducing patients’ sequelae. The currently used lepromin is not adequate for disease diagnosis and, so far, no antigen to be used in intradermoreaction has proved to be sensitive and specific for that purpose. Aiming at identifying new reagents to be used in skin tests, candidate antigens were investigated. Methods Random peptide phage display libraries were screened by using antibodies from leprosy patients in order to identify peptides as diagnostic reagents. Results Seven different phage clones were identified using purified antibodies pooled from sera of leprosy patients. When the clones were tested with serum samples by ELISA, three of them, 5A, 6A and 1B, allowed detecting a larger number of leprosy patients when compared to controls. The corresponding peptides expressed by selected phage clones were chemically synthesized. A pilot study was undertaken to assess the use of peptides in skin tests. The intradermal challenge with peptides in animals previously sensitized with Mycobacterium leprae induced a delayed-type hypersensitivity with peptide 5A (2/5 and peptide 1B (1/5. In positive controls, there was a 3/5 reactivity for lepromin and a 4/5 reactivity of the sensitized animals with soluble extract of M. leprae. Conclusions The preliminary data suggest that may be possible to develop reagents with diagnostic potential based on peptide mimotopes selected by phage display using polyclonal human antibodies.

  9. The hydrogen sulfide donor, Lawesson's reagent, prevents alendronate-induced gastric damage in rats

    Energy Technology Data Exchange (ETDEWEB)

    Nicolau, L.A.D. [Núcleo de Pesquisa em Produtos Naturais, Departamento de Farmacologia, Universidade Federal do Piauí, Teresina, PI (Brazil); Silva, R.O.; Damasceno, S.R.B.; Carvalho, N.S.; Costa, N.R.D. [Laboratório de Fisiofarmacologia Experimental, Centro de Pesquisa em Biodiversidade e Biotecnologia, Universidade Federal do Piauí, Parnaíba, PI (Brazil); Aragão, K.S. [Laboratório de Farmacologia da Inflamação e do Câncer, Departamento de Farmacologia, Universidade Federal do Ceará, Fortaleza, CE (Brazil); Barbosa, A.L.R. [Núcleo de Pesquisa em Produtos Naturais, Departamento de Farmacologia, Universidade Federal do Piauí, Teresina, PI (Brazil); Laboratório de Fisiofarmacologia Experimental, Centro de Pesquisa em Biodiversidade e Biotecnologia, Universidade Federal do Piauí, Parnaíba, PI (Brazil); Soares, P.M.G.; Souza, M.H.L.P. [Laboratório de Farmacologia da Inflamação e do Câncer, Departamento de Farmacologia, Universidade Federal do Ceará, Fortaleza, CE (Brazil); Medeiros, J.V.R. [Núcleo de Pesquisa em Produtos Naturais, Departamento de Farmacologia, Universidade Federal do Piauí, Teresina, PI (Brazil); Laboratório de Fisiofarmacologia Experimental, Centro de Pesquisa em Biodiversidade e Biotecnologia, Universidade Federal do Piauí, Parnaíba, PI (Brazil)

    2013-08-16

    Our objective was to investigate the protective effect of Lawesson's reagent, an H{sub 2}S donor, against alendronate (ALD)-induced gastric damage in rats. Rats were pretreated with saline or Lawesson's reagent (3, 9, or 27 µmol/kg, po) once daily for 4 days. After 30 min, gastric damage was induced by ALD (30 mg/kg) administration by gavage. On the last day of treatment, the animals were killed 4 h after ALD administration. Gastric lesions were measured using a computer planimetry program, and gastric corpus pieces were assayed for malondialdehyde (MDA), glutathione (GSH), proinflammatory cytokines [tumor necrosis factor (TNF)-α and interleukin (IL)-1β], and myeloperoxidase (MPO). Other groups were pretreated with glibenclamide (5 mg/kg, ip) or with glibenclamide (5 mg/kg, ip)+diazoxide (3 mg/kg, ip). After 1 h, 27 µmol/kg Lawesson's reagent was administered. After 30 min, 30 mg/kg ALD was administered. ALD caused gastric damage (63.35±9.8 mm{sup 2}); increased levels of TNF-α, IL-1β, and MDA (2311±302.3 pg/mL, 901.9±106.2 pg/mL, 121.1±4.3 nmol/g, respectively); increased MPO activity (26.1±3.8 U/mg); and reduced GSH levels (180.3±21.9 µg/g). ALD also increased cystathionine-γ-lyase immunoreactivity in the gastric mucosa. Pretreatment with Lawesson's reagent (27 µmol/kg) attenuated ALD-mediated gastric damage (15.77±5.3 mm{sup 2}); reduced TNF-α, IL-1β, and MDA formation (1502±150.2 pg/mL, 632.3±43.4 pg/mL, 78.4±7.6 nmol/g, respectively); lowered MPO activity (11.7±2.8 U/mg); and increased the level of GSH in the gastric tissue (397.9±40.2 µg/g). Glibenclamide alone reversed the gastric protective effect of Lawesson's reagent. However, glibenclamide plus diazoxide did not alter the effects of Lawesson's reagent. Our results suggest that Lawesson's reagent plays a protective role against ALD-induced gastric damage through mechanisms that depend at least in part on activation of ATP-sensitive potassium (K

  10. Method and cell lines for the production of monoclonal antibodies to human glycophorin A

    Science.gov (United States)

    Bigbee, W.L.; Fong, S.S.N.; Jensen, R.H.; Vanderlaan, M.

    Cloned mouse hybridoma cell lines have been established which continuously produce antibodies that differentiate between the M and N forms of human glycophorin A. These antibodies have potential application as human blood group reagents, as markers for terminally differentiated erythroid cells and as immunofluorescent labels of somatically variant human erythrocytes.

  11. First two-reagent vitamin D assay for general clinical chemistry.

    Science.gov (United States)

    Saida, Fakhri B; Padilla-Chee, Mario; Dou, Chao; Yuan, Chong

    2018-05-01

    Vitamin D is a lipid-soluble molecule that plays key physiological roles in the metabolism of calcium, phosphate and magnesium. Recent studies show that deficiency in vitamin D is linked to cardiovascular diseases, autoimmune diseases and cancer. As a result, regular monitoring of 25-OH vitamin D (the main circulating form of vitamin D) is becoming essential. Current 25-OH vitamin D testing methodologies are cumbersome (too many reagents, long incubation times, phase separation) and are not compatible with general clinical chemistry platforms. Here, we report on a novel method to detect 25-OH vitamin D that is fast (results in 10 min or less), simple (two reagents) and compatible with virtually all general clinical chemistry analyzers. An immunoturbidimetric assay for 25-OH vitamin D (the Diazyme EZ Vitamin D Assay) has been developed using nanoparticles and vitamin D-specific antibodies. The performance of the assay kit, which consists of two reagents and five calibrators, was tested on the Beckman AU680 analyzer (AU680). The new assay was precise, sensitive (LOD = 7.2 nmol/L), linear (up to 390.1 nmol/L) and correlated strongly (R 2  > 0.95) with major commercial 25-OH vitamin D assays. Additionally, the assay was found to be the fastest to date, with the first results obtained within 10 min. Throughput on the AU680 was estimated at over 300 tests per hour. The newly developed 25-OH vitamin D assay is fast, precise and accurate. It can be run on most general chemistry analyzers. This assay aims at providing vitamin D-testing capabilities to all clinical chemistry laboratories. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. 21 CFR 866.3940 - West Nile virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3940 West Nile... detection aids in the clinical laboratory diagnosis of viral meningitis/encephalitis caused by West Nile...

  13. Radioimmunoassay reagent and its use in a radioimmunoassay

    International Nuclear Information System (INIS)

    Polito, A.J.; Knight, W.S.

    1977-01-01

    A radioimmunoassay to detect or determine a steroid of the cortisone and aldosterone group has been developed. The invention particularly concerns a steroid derivative containing imidazole group which is radioactively labelled. The invented reagents are labelled with iodine 125. (VJ) [de

  14. Systematic Evaluation of Protein Reduction and Alkylation Reveals Massive Unspecific Side Effects by Iodine-containing Reagents.

    Science.gov (United States)

    Müller, Torsten; Winter, Dominic

    2017-07-01

    Reduction and alkylation of cysteine residues is part of virtually any proteomics workflow. Despite its frequent use, up to date no systematic investigation of the impact of different conditions on the outcome of proteomics studies has been performed. In this study, we compared common reduction reagents (dithiothreitol, tris-(2-carboxyethyl)-phosphine, and β-mercaptoethanol) and alkylation reagents (iodoacetamide, iodoacetic acid, acrylamide, and chloroacetamide). Using in-gel digests as well as SAX fractionated in-solution digests of cytosolic fractions of HeLa cells, we evaluated 13 different reduction and alkylation conditions resulting in considerably varying identification rates. We observed strong differences in offsite alkylation reactions at 7 amino acids as well as at the peptide N terminus, identifying single and double adducts of all reagents. Using dimethyl labeling, mass tolerant searches, and synthetic peptide experiments, we identified alkylation of methionine residues by iodine-containing alkylation reagents as one of the major factors for the differences. We observed differences of more than 9-fold in numbers of identified methionine-containing peptide spectral matches for in-gel digested samples between iodine- and noniodine-containing alkylation reagents. This was because of formation of carbamidomethylated and carboxymethylated methionine side chains and a resulting prominent neutral loss during ESI ionization or in MS/MS fragmentation, strongly decreasing identification rates of methionine-containing peptides. We achieved best results with acrylamide as alkylation reagent, whereas the highest numbers of peptide spectral matches were obtained when reducing with dithiothreitol and β-mercaptoethanol for the in-solution and the in-gel digested samples, respectively. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  15. Fenton's Reagent. Innovative Technology Summary Report

    International Nuclear Information System (INIS)

    None

    1999-01-01

    The Fenton's Reagent DNAPL treatment process is an in situ oxidation method to destroy DNAPLs in groundwater. Residual industrial solvents, primarily Dense Non-Aqueous Phase Liquids (DNAPLs), are currently the most significant barrier to successful completion of most large groundwater and soil cleanup efforts. DNAPL pools and residues slowly dissolve into surrounding groundwater to create large plumes of organic solvent contamination with concentration levels far above regulatory limits

  16. Quality control of radioimmunoassay reagents for T4

    International Nuclear Information System (INIS)

    Wayan Radiatning, S.

    1987-01-01

    Quality control of radioimmunoassay reagents for T4. A program of quality control testing has been carried out for 125 I-T4, T4 standards and T4 antisera. 125 I-labelled T4 has been tested for its specific activity, radiochemical purity using a Sephadex G-25 column, immunological activity, based on the immunological reaction between labelled antigen and excess T4 antibody, and non-specific binding. The useful shelf-life of the labelled compound was determined by monitoring the decrease in radiochemical purity and immunological activity, and the increase in non-specific binding. T4 standards were calibrated by means of T4 RIA kit manufactured by DPC (Diagnostic Products Corporation). A test on parallelism was also performed using hyperthyroid sera. T4 antisera were evaluated with respect to titre, avidity and specifity. The test results on 125 I-T4 show a specific activity varying between 1830-2020 uCi/ug, a radiochemical purity above 90%, an immunological more than 80% and a non-specific binding of less than 5%. The standard curve for T4 was found to coincide well with the standard curve of the DPC kit and parallel with the curve for hyperthyroid sera. The titre of T4 antisera obtained was 1:300, the avidity was about 4.8 x 10 7 and the cross-reaction for T3 was 1.6%. It can be concluded from the experimental results, that the 125 I-T4, T4 standards and T4 antisera prepared meet the requirements for the manufacture of T4 kits. (author). 5 refs.; 14 figs

  17. A Comparative Study on the Effect of Flotation Reagents on Growth and Iron Oxidation Activities of Leptospirillum ferrooxidans and Acidithiobacillus ferrooxidans

    Directory of Open Access Journals (Sweden)

    Mohammad Jafari

    2016-12-01

    Full Text Available Recently, extraction of metals from different resources using a simple, efficient, and low-cost technique-known as bioleaching-has been widely considered, and has turned out to be an important global technology. Leptospirillum ferrooxidans and Acidithiobacillus (Thiobacillus ferrooxidans are ubiquitous bacteria in the biomining industry. To date, the effects of commercial flotation reagents on the biooxidation activities of these bacteria have not been thoroughly studied. This investigation, by using various systematic measurement methods, studied the effects of various collectors and frothers (collectors: potassium amylxanthate, potassium isobutyl-xanthate, sodium ethylxanthate, potassium isopropylxanthate, and dithiophosphate; and frothers: pine oil and methyl isobutyl carbinol on L. ferrooxidans and A. ferrooxidans activities. In general, results indicate that in the presence of these collectors and frothers, L. ferrooxidans is less sensitive than T. ferrooxidans. In addition, the inhibition effect of collectors on both bacteria is recommended in the following order: for the collectors, potassium isobutyl-xanthate > dithiophosphate > sodium ethylxanthate > potassium isobutyl-xanthate > potassium amylxanthate; and for the frothers, methyl isobutyl carbinol > pine oil. These results can be used for the optimization of biometallurgical processes or in the early stage of a process design for selection of flotation reagents.

  18. Mechanism of red mud combined with Fenton's reagent in sewage sludge conditioning.

    Science.gov (United States)

    Zhang, Hao; Yang, Jiakuan; Yu, Wenbo; Luo, Sen; Peng, Li; Shen, Xingxing; Shi, Yafei; Zhang, Shinan; Song, Jian; Ye, Nan; Li, Ye; Yang, Changzhu; Liang, Sha

    2014-08-01

    Red mud was evaluated as an alternative skeleton builder combined with Fenton's reagent in sewage sludge conditioning. The results show that red mud combined with Fenton's reagent showed good conditioning capability with the pH of the filtrate close to neutrality, indicating that red mud acted as a neutralizer as well as a skeleton builder when jointly used with Fenton's reagent. Through response surface methodology (RSM), the optimal dosages of Fe(2+), H2O2 and red mud were proposed as 31.9, 33.7 and 275.1 mg/g DS (dry solids), respectively. The mechanism of the composite conditioner could be illuminated as follows: (1) extracellular polymeric substances (EPS), including loosely bound EPS and tightly bound EPS, were degraded into dissolved organics, e.g., proteins and polysaccharides; (2) bound water was released and converted into free water due to the degradation of EPS; and (3) morphology of the conditioned sludge exhibited a porous structure in contrast with the compact structure of raw sludge, and the addition of red mud formed new mineral phases and a rigid lattice structure in sludge, allowing the outflow of free water. Thus, sludge dewatering performance was effectively improved. The economic assessment for a wastewater treatment plant of 370,000 equivalent inhabitants confirms that using red mud conditioning, combined with Fenton's reagent, leads to a saving of approximately 411,000 USD/y or 50.8 USD/t DS comparing with using lime and ordinary Portland cement combined with Fenton's reagent, and approximately 612,000 USD/y or 75.5 USD/t DS comparing with the traditional treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. A Microfluidic Device for Preparing Next Generation DNA Sequencing Libraries and for Automating Other Laboratory Protocols That Require One or More Column Chromatography Steps

    Science.gov (United States)

    Tan, Swee Jin; Phan, Huan; Gerry, Benjamin Michael; Kuhn, Alexandre; Hong, Lewis Zuocheng; Min Ong, Yao; Poon, Polly Suk Yean; Unger, Marc Alexander; Jones, Robert C.; Quake, Stephen R.; Burkholder, William F.

    2013-01-01

    Library preparation for next-generation DNA sequencing (NGS) remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation. PMID:23894273

  20. A microfluidic device for preparing next generation DNA sequencing libraries and for automating other laboratory protocols that require one or more column chromatography steps.

    Directory of Open Access Journals (Sweden)

    Swee Jin Tan

    Full Text Available Library preparation for next-generation DNA sequencing (NGS remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation.

  1. 21 CFR 866.3085 - Brucella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3085 Brucella spp... from clinical specimens or to identify antibodies to Brucella spp. in serum. Additionally, some of... to identify Brucella spp. directly from clinical specimens or cultured isolates derived from clinical...

  2. 21 CFR 866.3235 - Epstein-Barr virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3235 Epstein-Barr... consist of antigens and antisera used in serological tests to identify antibodies to Epstein-Barr virus in...

  3. Verification test for on-line diagnosis algorithm based on noise analysis

    International Nuclear Information System (INIS)

    Tamaoki, T.; Naito, N.; Tsunoda, T.; Sato, M.; Kameda, A.

    1980-01-01

    An on-line diagnosis algorithm was developed and its verification test was performed using a minicomputer. This algorithm identifies the plant state by analyzing various system noise patterns, such as power spectral densities, coherence functions etc., in three procedure steps. Each obtained noise pattern is examined by using the distances from its reference patterns prepared for various plant states. Then, the plant state is identified by synthesizing each result with an evaluation weight. This weight is determined automatically from the reference noise patterns prior to on-line diagnosis. The test was performed with 50 MW (th) Steam Generator noise data recorded under various controller parameter values. The algorithm performance was evaluated based on a newly devised index. The results obtained with one kind of weight showed the algorithm efficiency under the proper selection of noise patterns. Results for another kind of weight showed the robustness of the algorithm to this selection. (orig.)

  4. Sulfonate-terminated carbosilane dendron-coated nanotubes: a greener point of view in protein sample preparation.

    Science.gov (United States)

    González-García, Estefanía; Gutiérrez Ulloa, Carlos E; de la Mata, Francisco Javier; Marina, María Luisa; García, María Concepción

    2017-09-01

    Reduction or removal of solvents and reagents in protein sample preparation is a requirement. Dendrimers can strongly interact with proteins and have great potential as a greener alternative to conventional methods used in protein sample preparation. This work proposes the use of single-walled carbon nanotubes (SWCNTs) functionalized with carbosilane dendrons with sulfonate groups for protein sample preparation and shows the successful application of the proposed methodology to extract proteins from a complex matrix. SEM images of nanotubes and mixtures of nanotubes and proteins were taken. Moreover, intrinsic fluorescence intensity of proteins was monitored to observe the most significant interactions at increasing dendron generations under neutral and basic pHs. Different conditions for the disruption of interactions between proteins and nanotubes after protein extraction and different concentrations of the disrupting reagent and the nanotube were also tried. Compatibility of extraction and disrupting conditions with the enzymatic digestion of proteins for obtaining bioactive peptides was also studied. Finally, sulfonate-terminated carbosilane dendron-coated SWCNTs enabled the extraction of proteins from a complex sample without using non-environmentally friendly solvents that were required so far. Graphical Abstract Green protein extraction from a complex sample employing carbosilane dendron coated nanotubes.

  5. N-m-nitrocinnamoylphenylhydroxyl-amine as reagent for amperometric determination of yttrium

    International Nuclear Information System (INIS)

    Oliferenko, G.L.; Gallaj, Z.A.; Sheina, N.M.; Shvedene, N.V.

    1983-01-01

    Possibility of using organic reagent of unsaturated N-arylsubstituted derivatives class of hydroxamic acids N-m-nitrocinnamoyl phenylhydroxylamire (NCPHA) for amperometric titration of yttrium using indication of e.t.p. by current of reagent oxidation on graphite electrode is investigated. Metal and the NCPHA form difficultly soluble complex with ratio of yttrium to the NCPHA, which is equal to 1:3. Buffer mixtures of 0.1MNH 3 +0.1MCH 3 COOH composis tion with pH 6.3-7.5 are optimal background solutions for amperometric titration of yttrium. The proposed method permits to determine 10-600 μkg of yttrium in the volume of 10 ml. Effect of the series of strange elements on titration of yttrium with NCPHA (Ca, Mg, Mn (2), Al, CU (2), Fe (3) REE and others) is studied. The developed method is used for yttrium determination in luminophores of Casub(n)-- Ysub(m)Fsub(z)xMn(2) (1-10%) composition

  6. Induction of apoptosis in human choriocarcinoma cell lines by treatment with 3,4-dihydro-6-[4-(3,4-dimethoxybenzoyl)-1-piperazinyl]-2(1H)-quinolinone (vesnarinone).

    Science.gov (United States)

    Isaka, Keiichi; Fujito, Atsuya; Sagawa, Yasukazu; Yudate, Tamaki; Nishi, Hirotaka; Ito, Hiroe; Takayama, Masaomi

    2002-01-01

    Induction of apoptosis is an attractive strategy in cancer therapy but it clinical practice is not yet sufficient in choriocarcinoma. The quinolinone derivative, vesnarinone, is a novel inotropic agent used for treating congestive heart failure and may also have a potential anticancer activity. It induces apoptosis and differentiation in some tumor cell lines. We examined the antitumor effect of vesnarinone in eight cell lines established from human choriocarcinoma and hydatidiform mole using MTT assay and also analyzed the nuclear fragmentation of tumor cells by DNA electrophoresis assay. Vesnarinone inhibited the proliferation of choriocarcinoma cell lines in a dose-dependent manner and induced DNA fragmentation in cells. However, the BM cell line prepared by subcultivation from hydatidiform mole showed no growth suppression or DNA fragmentation in response to vesnarinone. On the other hand, PCR-SSCP analysis and direct DNA sequencing have shown that a human choriocarcinoma cell line, SCH, has a mutant p53 gene at codon 249. When SCH cells were treated with vesnarinone cellular proliferation was significantly inhibited. Vesnarinone suppressed the proliferation of all choriocarcinoma cell lines and induced apoptosis, regardless of the existence of p53 mutation. In addition, it has been found by RT-PCR that expression of c-Myc mRNA is upregulated by treating choriocarcinoma cells with vesnarinone. The finding suggests that vesnarinone might induce expression of c-Myc gene in choriocarcinoma cells, the product of which may be associated with the inhibition of cell growth and induce apoptosis. These results suggest that vesnarinone is a useful reagent for the treatment of choriocarcinoma.

  7. Impact of pig insemination technique and semen preparation on profitability.

    Science.gov (United States)

    Gonzalez-Peña, D; Knox, R V; Pettigrew, J; Rodriguez-Zas, S L

    2014-01-01

    Artificial insemination technique and semen preparation impact boar utilization efficiency, genetic dissemination, and biosecurity. Intrauterine (IUI) and deep intrauterine (DUI) AI techniques require lower number of spermatozoa per dose compared to conventional (CON) AI. Frozen semen (FRO) has been associated with lower reproductive performance compared to fresh semen (FRE) preparation. The combined effects of 3 AI techniques (CON, IUI, and DUI) and 2 semen preparations (FRE and FRO) on the financial indicators of a pig crossbreeding system were studied. A 3-tier system was simulated in ZPLAN and the genetic improvement in a representative scenario was characterized. The cross of nucleus lines B and A generated 200,000 BA sows at the multiplier level. The BA sows were inseminated (CON, IUI, or DUI) with FRE or FRO from line C boars at the commercial level. Semen preparation and AI technique were represented by distinct sow:boar ratios in the C × BA cross. A range of farrowing rates (60 to 90%) and litter sizes (8 to 14 liveborn pigs) were tested. Genetic improvement per year for number born alive, adjusted 21-d litter weight, days to 113.5 kg, backfat, and ADG were 0.01 pigs per litter, 0.06 kg, -0.09 d, -0.29 mm, and 0.88 g, respectively. On average, the net profit for FRE (FRO) increased (P-value profit between techniques were driven by differences in costs. Differences in fixed costs between IUI and DUI relative to CON were -2.4 (-5.2%) and -3.4% (-7.4%), respectively. The differences in total costs between FRE and FRO were lower than -5%. The difference in variable costs between FRE and FRO ranged from -5.3 (CON) to -24.7% (DUI). Overall, insemination technique and semen preparation had a nonlinear effect on profit. The average relative difference in profit between FRE and FRO was less than 3% for the scenarios studied.

  8. Evaluation of Directions for Use Compatibility Between Different Brands Strips Urine Reagent

    Directory of Open Access Journals (Sweden)

    Guilherme de Oliveira Cezar

    2012-06-01

    Full Text Available Through the urine test we can measure kidney function and identify pathologies of the urinary tract. The urine test strips are a fast, easy and increasingly used method of analysis. It is extremely important to check compatibility between the different brands assuring a better understanding of the diagnosis. We compared the package inserts of eight different brands of urine test strips and the reagents used in the urinary determination, besides information concerning the detection of limit ranges, reading intervals and possible interferences. A comparison of the leaflets showed differences among them. Concerning the reagents used, in general, all brands use similar ones but in different quantities. The patient information leaflets have several interferences, but it was observed that some brands do not mention the interferences that are mentioned in other brands. As for the legends of semiquantitative measurements, most brands do not include this information on the product leaflet. Among the brands that could be analyzed with this parameter was observed that the analytes glucose, bilirubin, ketones and blood did not have the same correlation between concentration and label brands. We stress the importance of ensuring a greater standardization of the information contained in the leaflets of the reagent strips.

  9. 21 CFR 864.1860 - Immunohistochemistry reagents and kits.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Immunohistochemistry reagents and kits. 864.1860 Section 864.1860 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Biological Stains § 864.1860...

  10. The potential of P1 site alterations in peptidomimetic protease inhibitors as suggested by virtual screening and explored by the use of C-C-coupling reagents.

    Science.gov (United States)

    Weik, Steffen; Luksch, Torsten; Evers, Andreas; Böttcher, Jark; Sotriffer, Christoph A; Hasilik, Andrej; Löffler, Hans-Gerhard; Klebe, Gerhard; Rademann, Jörg

    2006-04-01

    A synthetic concept is presented that allows the construction of peptide isostere libraries through polymer-supported C-acylation reactions. A phosphorane linker reagent is used as a carbanion equivalent; by employing MSNT as a coupling reagent, the C-acylation can be conducted without racemization. Diastereoselective reduction was effected with L-selectride. The reagent linker allows the preparation of a norstatine library with full variation of the isosteric positions including the P1 side chain that addresses the protease S1 pocket. Therefore, the concept was employed to investigate the P1 site specificity of peptide isostere inhibitors systematically. The S1 pocket of several aspartic proteases including plasmepsin II and cathepsin D was modeled and docked with approximately 500 amino acid side chains. Inspired by this virtual screen, a P1 site mutation library was designed, synthesized, and screened against three aspartic proteases (plasmepsin II, HIV protease, and cathepsin D). The potency of norstatine inhibitors was found to depend strongly on the P1 substituent. Large, hydrophobic residues such as biphenyl, 4-bromophenyl, and 4-nitrophenyl enhanced the inhibitory activity (IC50) by up to 70-fold against plasmepsin II. In addition, P1 variation introduced significant selectivity, as up to 9-fold greater activity was found against plasmepsin II relative to human cathepsin D. The active P1 site residues did not fit into the crystal structure; however, molecular dynamics simulation suggested a possible alternative binding mode.

  11. Avaliação do desempenho dos reagentes do tempo de tromboplastina parcial ativada utilizados para detectar o anticoagulante lúpico Assessment of the performance of reagents of activated partial thromboplastin time used to detect the lupus anticoagulant

    Directory of Open Access Journals (Sweden)

    Fernanda Chiuso

    2005-06-01

    Full Text Available INTRODUÇÃO: O anticoagulante lúpico é uma imunoglobulina pertencente à família dos anticorpos antifosfolípides. A sua ação in vitro é interferir nos testes de coagulação dependentes de fosfolípides. O tempo de tromboplastina parcial ativada (TTPA é um teste utilizado como screening na pesquisa do anticoagulante lúpico. Os reagentes utilizados neste teste apresentam grandes variações quanto à sensibilidade. OBJETIVO: Avaliar o desempenho dos reagentes do TTPA e detectar a presença do anticoagulante lúpico através de diferentes testes da coagulação. MATERIAL E MÉTODO: A pesquisa do anticoagulante lúpico foi realizada em 50 amostras plasmáticas de pacientes do sexo feminino através dos testes do TTPA, do tempo de coagulação do caulim (TCC, do tempo de tromboplastina parcial ativada diluída (TTPAd e do tempo do veneno da víbora de Russel diluído (TVVRd. Três cefalinas comerciais foram avaliadas pelos testes do TTPA e do TTPAd. Na comparação entre os reagentes estudados foi aplicado o cálculo do intervalo de confiança (95%. RESULTADOS: Os três reagentes avaliados apresentaram boa concordância e os métodos utilizados responderam bem à pesquisa do anticoagulante lúpico. DISCUSSÃO E CONCLUSÃO: As três cefalinas comerciais avaliadas podem ser utilizadas na rotina laboratorial para a pesquisa do anticoagulante lúpico.INTRODUCTION: The lupus anticoagulant is an immunoglobin which belongs to the antiphospholid antibodies family. Its in vitro function is to interfere with coagulation tests that are dependent on phospholipids. The activated partial thromboplastin time (APTT is a test used as screening on lupus anticoagulant research. Reagents used in this test demonstrate wide sensitivity ranges. OBJECTIVE: To assess the performance of APTT reagents and detect the presence of lupus anticoagulant through various coagulation tests. MATERIAL AND METHOD: The lupus anticoagulant research was performed in plasma from 50

  12. Microfluidics in the selection of affinity reagents for the detection of cancer: paving a way towards future diagnostics.

    Science.gov (United States)

    Hung, Lien-Yu; Wang, Chih-Hung; Fu, Chien-Yu; Gopinathan, Priya; Lee, Gwo-Bin

    2016-08-07

    Microfluidic technologies have miniaturized a variety of biomedical applications, and these chip-based systems have several significant advantages over their large-scale counterparts. Recently, this technology has been used for automating labor-intensive and time-consuming screening processes, whereby affinity reagents, including aptamers, peptides, antibodies, polysaccharides, glycoproteins, and a variety of small molecules, are used to probe for molecular biomarkers. When compared to conventional methods, the microfluidic approaches are faster, more compact, require considerably smaller quantities of samples and reagents, and can be automated. Furthermore, they allow for more precise control of reaction conditions (e.g., pH, temperature, and shearing forces) such that more efficient screening can be performed. A variety of affinity reagents for targeting cancer cells or cancer biomarkers are now available and will likely replace conventional antibodies. In this review article, the selection of affinity reagents for cancer cells or cancer biomarkers on microfluidic platforms is reviewed with the aim of highlighting the utility of such approaches in cancer diagnostics.

  13. Spectroscopic studies on surface reactions between minerals and reagents in flotation systems

    International Nuclear Information System (INIS)

    Giesekke, E.W.

    1981-01-01

    A study of the adsorbed species at the interface between the minerals and the aqueous solution is reported in the hope that it will contribute to a better understanding of selective mineral flotation by various reagents. The results of infrared spectroscopic studies are cited from the author's investigation on the fluorite-sodium oleate and fluorite-linoleate systems. Electron-spectroscopic techniques, e.g., electron spectroscopy for chemical analysis (ESCA) have also been useful in the identification of adsorbed species on mineral surfaces. Some experimental data from the literature are discussed. These studies have the disadvantage that they are not in situ investigations of the interface between the mineral and the aqueous solution. The potential use of other spectroscopic techniques are discussed, photo-acoustic, Raman, and electron-spin-resonance spectroscopy being considered as possible alternatives. It is suggested that the relatively small surface areas of minerals used in flotation (i.e. smaller than 2m 2 .g- 1 ) impose severe restrictions on the use of such techniques

  14. Effect of reagent type on the froth floatation of Sokoto phosphate ore

    Directory of Open Access Journals (Sweden)

    U.A. Hassan

    2016-06-01

    Full Text Available Effect of reagent type on the froth floatation of Sokoto phosphate ore for its beneficiation has been established. The samples of the Sokoto phosphate mineral ore used for the research work were sourced from mining locations in Dange-Shuni, Bodinga, Yabo, Wurno, and Rabbah Local Government Areas of Sokoto State. Size-Assay analysis conducted on scrubbed Sokoto Phosphates nodules revealed that nodules had a size distribution with 80% passing 29.3 mm. Flotation Tests using AERO704 (fatty Acid, Alkyl Hydroxamates, Melamine as collectors (alone or mixed with diesel, MIBC as frother, Calcium Hydroxide and Sulphuric Acid as pH regulators and Dextrin, Sodium Silicate and Aluminium Chloride as depressants produced poor P2O5 separation in the flotation products due to very poor liberation associated with very fine mineral grains. Based on the results obtained, AERO704 Collector gave the best result with aP2O5 recovery pH of 10.

  15. Preparation and Characterization of Super-paramagnetic Nano-beads for DNA Isolation

    Institute of Scientific and Technical Information of China (English)

    Xin XIE; Xu ZHANG; Bing Bin YU; wei Yang FE

    2004-01-01

    Unique coupling reagent, bis-(2-hydroxyethyl methacrylate) phosphate was used to prepare coated and functionalized superparamagnetic nanobeads, leading to a simple, effective method for coating the nanobeads. With this method, the thickness of the coating layer and the functional group contents on the nano-beads could be controlled by changing the quantity of the coated monomers. The nanobeads were characterized by means of transmission electron microscopy (TEM) and Fourier transformation infrared spectroscopy (FTIR). The carboxyl-modified magnetic nano-beads were employed to streamline the protocol of isolation of genomic DNA from the human whole blood.

  16. Trifluoromethanesulfonic Anhydride as a Low-Cost and Versatile Trifluoromethylation Reagent.

    Science.gov (United States)

    Ouyang, Yao; Xu, Xiu-Hua; Qing, Feng-Ling

    2018-04-19

    A large number of reagents have been developed for the synthesis of trifluoromethylated compounds. However, an ongoing challenge in trifluoromethylation reaction is the use of less expensive and practical trifluoromethyl sources. We report herein the unprecedented direct trifluoromethylation of (hetero)arenes using trifluoromethanesulfonic anhydride as a radical trifluoromethylation reagent by merging photoredox catalysis and pyridine activation. Furthermore, introduction of both the CF 3 and OTf groups of the trifluoromethanesulfonic anhydride into internal alkynes to access tetrasubstituted trifluoromethylated alkenes was achieved. Since trifluoromethanesulfonic anhydride is a low-cost and abundant chemical, this method provides a cost-efficient and practical route to trifluoromethylated compounds. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. 21 CFR 866.3510 - Rubella virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3510 Rubella virus... Clinical Laboratory Standards': (i) 1/LA6 “Detection and Quantitation of Rubella IgG Antibody: Evaluation... Products in the Clinical Laboratory, October 1997,” (ii) 1/LA18 “Specifications for Immunological Testing...

  18. A procedure for preparing alkali metal hydrides

    International Nuclear Information System (INIS)

    Lemieux, R.U.; Sanford, C.E.; Prescott, J.F.

    1976-01-01

    A plain low cost, procedure for the continuous, low temperature preparation of sodium or potassium hydrides using cheap reagents is presented. Said invention is especially concerned with a process of purifying of a catalytic exchange liquid used for deuterium enrichment, in which an alkali metal hydride is produced as intermediate product. The procedure for producing the sodium and potassium hydrides consists in causing high pressure hydrogen to be absorbed by a mixture of at least a lower monoalkylamine and an alkylamide of an alkali metal from at least one of said amines [fr

  19. 21 CFR 864.9225 - Cell-freezing apparatus and reagents for in vitro diagnostic use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cell-freezing apparatus and reagents for in vitro diagnostic use. 864.9225 Section 864.9225 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH... Establishments That Manufacture Blood and Blood Products § 864.9225 Cell-freezing apparatus and reagents for in...

  20. Application of Fenton's reagent as a pretreatment step in biological degradation of polyaromatic hydrocarbons

    International Nuclear Information System (INIS)

    Kelley, R.L.; Gauger, W.K.; Srivastava, V.J.

    1991-01-01

    Fenton's reagent (H 2 O 2 and Fe ++ ) has been used for chemical oxidation of numerous organic compounds in water treatment schemes. In this study, the Institute of Gas Technology (IGT) applied Fenton's treatment to polynuclear aromatic hydrocarbons (PAHs) and PAH-contaminated soils. Fenton's treatment was very reactive with PAHs, causing rapid modification of the parental compounds to oxidized products and complete degradation to CO 2 . This treatment was more effective on chemically reactive PAHs, such as benzo(a)pyrene and phenanthrene. Important parameters and conditions for Fenton's treatment of PAHs in solution and soil matrices have been identified. As much as 99% of the PAHs on soil matrices can be removed by treatment with Fenton's reagent

  1. The socio-economic base line survey; first chapter of the handbook under preparation: "Managing farmers: a handbook for working with farmers in irrigation and drainage projects"

    NARCIS (Netherlands)

    Schrevel, A.

    2002-01-01

    The text The socio-economic base line survey is the first chapter of a book under preparation meant to instruct senior staff of irrigation and drainage projects on techniques to work with farmers. It informs the reader of best practices to set up and execute a socio-economic baseline survey. The

  2. X-ray line profile analysis of BaTiO3 thin film prepared by sol-gel deposition

    Science.gov (United States)

    Ooi, Zeen Vee; Saif, Ala'eddin A.; Wahab, Yufridin; Jamal, Zul Azhar Zahid

    2017-04-01

    Barium titanate (BaTiO3) thin film was prepared using sol-gel method and spun-coated on SiO2/Si substrate. The phase and crystallinity of the synthesized film were identified using X-ray diffractometer (XRD), which scanned at the range of 20° to 60°. The phase and lattice parameters of the fabricated film were extracted from the recorded XRD patterns using lattice geometry equations. The crystallite size and lattice strain were determined using X-ray line profile analysis (XLPA) with various approaches. The Scherrer equation was applied to the perovskite peaks of the film to explore the size contribution on the peak broadening. Meanwhile, the Williamson-Hall and size-strain plot (SSP) methods were used to review two main independent contributions, i.e. crystallite sizes and lattice strain, on the X-ray line broadening. From the analysis, it is found that Scherrer method gives smallest crystallite size value by ignoring the strain-induced broadening effect. On the other hand, Williamson-Hall and SSP graphs revealed the existence of the lattice strain within the film, which contributes to the broadening in the Bragg peak. The results that analyzed via both techniques show a linear trend with all data points fitted. However, result obtained from SSP method gives better settlement due to the best fit of the data.

  3. Spatial and Temporal Control of Cavitation Allows High In Vitro Transfection Efficiency in the Absence of Transfection Reagents or Contrast Agents.

    Science.gov (United States)

    Chettab, Kamel; Roux, Stéphanie; Mathé, Doriane; Cros-Perrial, Emeline; Lafond, Maxime; Lafon, Cyril; Dumontet, Charles; Mestas, Jean-Louis

    2015-01-01

    Sonoporation using low-frequency high-pressure ultrasound (US) is a non-viral approach for in vitro and in vivo gene delivery. In this study, we developed a new sonoporation device designed for spatial and temporal control of ultrasound cavitation. The regulation system incorporated in the device allowed a real-time control of the cavitation level during sonoporation. This device was evaluated for the in vitro transfection efficiency of a plasmid coding for Green Fluorescent Protein (pEGFP-C1) in adherent and non-adherent cell lines. The transfection efficiency of the device was compared to those observed with lipofection and nucleofection methods. In both adherent and non-adherent cell lines, the sonoporation device allowed high rate of transfection of pEGFP-C1 (40-80%), as determined by flow cytometry analysis of GFP expression, along with a low rate of mortality assessed by propidium iodide staining. The transfection efficiency and toxicity of sonoporation on the non-adherent cell lines Jurkat and K562 were similar to those of nucleofection, while these two cell lines were resistant to transfection by lipofection. Moreover, sonoporation was used to produce three stably transfected human lymphoma and leukemia lines. Significant transfection efficiency was also observed in two fresh samples of human acute myeloid leukemia cells. In conclusion, we developed a user-friendly and cost-effective ultrasound device, well adapted for routine in vitro high-yield transfection experiments and which does not require the use of any transfection reagent or gas micro-bubbles.

  4. On-Line Monitoring of Instrument Channel Performance: Volume 3: Applications to Nuclear Power Plant Technical Specification Instrumentation

    International Nuclear Information System (INIS)

    Davis, E.; Rasmussen, B.

    2004-01-01

    This report is a guide for a technical specification change submittal and subsequent implementation of on-line monitoring for safety-related applications. This report is the third in a three-volume set. Volume 1, ''Guidelines for Model Development and Implementation'', presents the various tasks that must be completed to prepare models for and to implement an on-line monitoring system

  5. Action Intentions: Action Influences Both On-Line Perception and Off-Line Representation

    Directory of Open Access Journals (Sweden)

    C Kirtley

    2014-08-01

    Full Text Available Given that one role of vision is to gather information for upcoming tasks, previous studies have investigated whether the preparation for action affects visual behaviour. The current studies aimed to determine if such influences on visual selection would also influence the formation of subsequent memory representations. Two experiments were conducted- in the first, participants' action intentions towards a scene were manipulated by the performance of different grasping postures as they observed the scene. This was followed by a memory test for the objects presented. Participants' eye movements were affected by their action intention, so that performing a power grip led to significantly longer fixation durations on power grip compatible objects. In contrast, memory for the objects and their properties was not affected by the action. Our second study required participants to make the action posture during the recall phase. No effect on eye movements was found, but recall was affected, with a particular advantage for recall of the position of grip-compatible objects. Previous studies have shown that action intentions can affect the on-line perception of objects. The current study suggests this may not extend to off-line representations if they are accessed after the action has been completed or abandoned. However, the recall of information may be affected if gestures are formed during retrieval. Memory representations may not be tailored specifically to an action, but actions can still affect the recall of information.

  6. Method of Generating Hydrocarbon Reagents from Diesel, Natural Gas and Other Logistical Fuels

    Science.gov (United States)

    Herling, Darrell R [Richland, WA; Aardahl, Chris L [Richland, WA; Rozmiarek, Robert T [Middleton, WI; Rappe, Kenneth G [Richland, WA; Wang, Yong [Richland, WA; Holladay, Jamelyn D [Kennewick, WA

    2008-10-14

    The present invention provides a process for producing reagents for a chemical reaction by introducing a fuel containing hydrocarbons into a flash distillation process wherein the fuel is separated into a first component having a lower average molecular weight and a second component having a higher average molecular weight. The first component is then reformed to produce synthesis gas wherein the synthesis gas is reacted catalytically to produce the desire reagent.

  7. Sorption-reagent treatment of brines produced by reverse osmosis unit for liquid radioactive waste management

    International Nuclear Information System (INIS)

    Avramenko, V. A.; Zheleznov, V. V.; Sergienko, V. I.; Chizhevsky, I. Yu

    2003-01-01

    The results of the pilot plant tests (2002-2003) of the sorption-reagent decontamination of high salinity radioactive waste (brines) remaining after the low-salinity liquid radioactive waste (LRW) treatment in the reverse-osmosis unit from long-lived radionuclides are presented. The sorption-reagent materials used in this work were developed in the Institute of Chemistry FEDRAS. They enable one to decontaminate brines with total salt content up to 50 g/l from long-lived radionuclides of Cs, Sr and Co. At joint application of the reverse-osmosis and sorption-reagent technologies total volume of solid radioactive waste (SRW) decreases up to 100-fold as compared to the technology of cementation of reverse osmosis brines. In this case total cost of LRW treatment and SRW disposal decreases more than 10-fold. Brines decontaminated from radionuclides are then diluted down to the ecologically safe total salts content in water to be disposed of. Tests were performed to compare the efficiency of technologies including evaporation of brines remaining after reverse osmosis process and their decontamination by means of the sorption-reagent method. It was shown that, as compared to evaporation, the sorption-reagent technology provides substantial advantages as in regard to radioactive waste total volume reduction as in view of total cost of the waste management

  8. 21 CFR 866.3390 - Neisseria spp. direct serological test reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3390... Neisseria spp. directly from clinical specimens. The identification aids in the diagnosis of disease caused...

  9. Protein-Protein Interaction Reagents | Office of Cancer Genomics

    Science.gov (United States)

    The CTD2 Center at Emory University has a library of genes used to study protein-protein interactions in mammalian cells. These genes are cloned in different mammalian expression vectors. A list of available cancer-associated genes can be accessed below. Emory_CTD^2_PPI_Reagents.xlsx Contact: Haian Fu

  10. Inactivation of Escherichia coli glycerol kinase by 5'-(p-(fluorosulfonyl)benzoyl))adenosine: protection by the hydrolyzed reagent

    Energy Technology Data Exchange (ETDEWEB)

    Pettigrew, D.W.

    1987-03-24

    Incubation of Escherichia coli glycerol kinase with 5'-(p-(fluorosulfonyl)benzoyl)adenosine (FSO/sub 2/BzAdo) at pH 8.0 and 25/sup 0/C results in the loss of enzyme activity, which is not restored by the addition of ..beta..-mercaptoethanol or dithiothreitol. The FSO/sub 2/BzAdo concentration dependence of the inactivation kinetics is described by a mechanism that includes the equilibrium binding of the reagent to the enzyme prior to a first-order inactivation reaction in addition to effects of reagent hydrolysis. The hydrolysis of the reagent has two effects on the observed kinetics. The first effect is deviation from pseudo-first-order kinetic behavior due to depletion of the reagent. The second effect is the novel protection of the enzyme from inactivation due to binding of the sulfonate hydrolysis product. Determinations of the reaction stoichiometry with /sup 3/H-labeled FSO/sub 2/BzAdo show that the inactivation is associated with the covalent incorporation of 1.08 mol of reagent/mol of enzyme subunit. Ligand protection experiments show that ATP, AMP, dAMP, NADH, 5'-adenylyl imidodiphosphate, and the sulfonate hydrolysis product of FSO/sub 2/BzAdo provide protection from inactivation. The protection obtained with ATMP is not dependent on Mg/sup 2 +/. The results are consistent with modification by FSO/sub 2/BzAdo of a single adenine nucleotide binding site per enzyme subunit.

  11. TAPIR: a device for automatic titration with incremental weighing of the titration reagent

    International Nuclear Information System (INIS)

    Ganivet, Michel

    TAPIR is a titration device enabling automatic analyses with weighting of the titration reagent. The titration method used can be based on potentiometry, amperometry, color indicator change... The reproducibility is about 3.10 -4 [fr

  12. A survey of some metallographic etching reagents for restoration of obliterated engraved marks on aluminium-silicon alloy surfaces.

    Science.gov (United States)

    Uli, Norjaidi; Kuppuswamy, R; Amran, Mohd Firdaus Che

    2011-05-20

    A brief survey to assess the sensitivity and efficacy of some common etching reagents for revealing obliterated engraved marks on Al-Si alloy surfaces is presented. Experimental observations have recommended use of alternate swabbing of 10% NaOH and 10% HNO(3) on the obliterated surfaces for obtaining the desired results. The NaOH etchant responsible for bringing back the original marks resulted in the deposition of some dark coating that has masked the recovered marks. The coating had been well removed by dissolving it in HNO(3) containing 10-20% acid. However, the above etching procedure was not effective on aluminium (99% purity) and Al-Zn-Mg-Cu alloy surfaces. Also the two reagents (i) immersion in 10% aq. phosphoric acid and (ii) alternate swabbing of 60% HCl and 40% NaOH suggested earlier for high strength Al-Zn-Mg-Cu alloys [23] were quite ineffective on Al-Si alloys. Thus different aluminium alloys needed different etching treatments for successfully restoring the obliterated marks. Al-Si alloys used in casting find wide applications especially in the manufacture of engine blocks of motor vehicles. Hence, the results presented in this paper are of much relevance in serial number restoration problems involving this alloy. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  13. Reagent strip testing is not sensitive for the screening of asymptomatic bacteriuria in pregnant women.

    Science.gov (United States)

    Lumbiganon, Pisake; Chongsomchai, Chompilas; Chumworathayee, Bundit; Thinkhamrop, Jadsada

    2002-08-01

    The objective of the study was to assess the diagnostic performance of the reagent strip in screening for asymptomatic bacteriuria in pregnant women using urine culture as a gold standard. This study comprised 204 asymptomatic pregnant women who attended their first antenatal care at Srinagarind Hospital, Khon Kaen University from April 1, 1999 to June 30, 1999. Women with symptoms of urinary tract infection, antibiotic treatment within the previous 7 days, pregnancy-induced hypertension, bleeding per vagina and history of urinary tract diseases were excluded. Urine specimens were collected by clean catched midstream urine technique for urinalysis, reagent strip test and urine culture. Diagnostic performance of reagent strip in terms of sensitivity, specificity, positive and negative predictive value was analyzed. Urine reagent strip test had a sensitivity of 13.9 per cent, a specificity of 95.6 per cent, a positive predictive value of 46.1 per cent, a negative predictive value of 80.6 per cent in detecting asymptomatic bacteriuria in pregnant women.

  14. Evaluation of Tropaeolin 000-1 as a Colorimetric Reagent for Assay ...

    African Journals Online (AJOL)

    Purpose: To explore the application of tropaeolin 000-1 reagent for the rapid, precise and accurate determination of duloxetine hydrochloride (DX) and escitalopram maleate (ECT). Methods: Determination of DX and ECT was based on the formation of complexes between the dye, DX and ECT in 0.1 M HCl. The resulting ...

  15. Transmission line capital costs

    International Nuclear Information System (INIS)

    Hughes, K.R.; Brown, D.R.

    1995-05-01

    The displacement or deferral of conventional AC transmission line installation is a key benefit associated with several technologies being developed with the support of the U.S. Department of Energy's Office of Energy Management (OEM). Previous benefits assessments conducted within OEM have been based on significantly different assumptions for the average cost per mile of AC transmission line. In response to this uncertainty, an investigation of transmission line capital cost data was initiated. The objective of this study was to develop a database for preparing preliminary estimates of transmission line costs. An extensive search of potential data sources identified databases maintained by the Bonneville Power Administration (BPA) and the Western Area Power Administration (WAPA) as superior sources of transmission line cost data. The BPA and WAPA data were adjusted to a common basis and combined together. The composite database covers voltage levels from 13.8 to 765 W, with cost estimates for a given voltage level varying depending on conductor size, tower material type, tower frame type, and number of circuits. Reported transmission line costs vary significantly, even for a given voltage level. This can usually be explained by variation in the design factors noted above and variation in environmental and land (right-of-way) costs, which are extremely site-specific. Cost estimates prepared from the composite database were compared to cost data collected by the Federal Energy Regulatory Commission (FERC) for investor-owned utilities from across the United States. The comparison was hampered because the only design specifications included with the FERC data were voltage level and line length. Working within this limitation, the FERC data were not found to differ significantly from the composite database. Therefore, the composite database was judged to be a reasonable proxy for estimating national average costs

  16. Performing in-situ chemical oxidation with Fenton's Reagent at a former gas work in Rotterdam

    Energy Technology Data Exchange (ETDEWEB)

    Plaisier, W.; Pancras, T. [In-situ Technieken BV, Wageningen (Netherlands); Bennen, M.; Bouwhuis, E. [Public Works Rotterdam (Netherlands)

    2003-07-01

    In-Situ Technieken BV is the first company in the Netherlands to apply full-scale in-situ chemical oxidation (ISCO) by means of Fenton's reagent or permanganates. The use of ISCO for soil remediation purposes originated in the USA. After three years of practical experience in the Netherlands it can be stated that ISCO has become a proven technology for source area treatment in the Netherlands as well. We present the results of a pilot ISCO treatment program with Fenton's reagent that was performed at the former gas works facility 'Feyenoord'. The site is one of the largest gas works facilities built in Rotterdam. The former gas production activities have lead to severe pollution of soil and groundwater over an area of approximately 3 hectares. Both laboratory and field observations showed that it would be very difficult to execute an efficient Fenton's reagent ISCO treatment program at this specific site for the following reasons. First of all, the contamination consisting of tar and tar-related compounds is found in an anthropogenic (man-made) soil of 9 meter in thickness. Secondly, high contents of carbonates and organic material were found in the soils, which act as a scavenger for the hydroxyl free radical in a Fenton's reagent ISCO system. The pilot test was performed in two phases with an intermediate period of 2 months. The injection of totally 24 tonnes hydrogen peroxide (50%) was anticipated. Reactions of the reagents in the soil were very strong. The presence of old (forgotten) boreholes and an intensive drainage system, in combination with the aggressive reaction resulted in short-circuiting of reagents to the surface. Out of the proposed 24 tonnes of hydrogen peroxide (50%) only 14.5 tonnes were injected. This would have effect on the amount of contamination oxidized. Nevertheless, the oxidation had a significant effect on the soil contamination. A reduction of approximately 90% for PAH was obtained. Reduction was also

  17. Evaluation of Questionnaire, Reagent Strip and Egg Count as ...

    African Journals Online (AJOL)

    A longitudinal study covering 55 months evaluated the three diagnostic tools used for confirmation of prevalence of urinary schistosomiasis among 1151 consented primary school pupils in 13 communities of Edo State, Nigeria. Questionnaire, reagent strip method and parasitological examination were employed.

  18. Protein assisted fluorescence enhancement of a dansyl containing fluorescent reagent: detection of Hg+ ion in aqueous medium.

    Science.gov (United States)

    Srivastava, Priyanka; Shahid, Mohammad; Misra, Arvind

    2011-07-21

    Intramolecular charge transfer (ICT) based fluorescent reagents containing a dansyl fluorophore have been synthesized and characterized. The reagent 1 and its complex, 1+Hg(2+) in sodium acetate buffer (pH 6.7) revealed considerable fluorescence enhancement (switched-on) in the presence of bovine serum albumin (BSA) with 10 ppb detection sensitivity. (1)H NMR spectral analysis suggests complexation between 1 and Hg(2+) ion involving the N,N-dimethylamino and carboxylic functions.

  19. Protected diazonium salts: a continuous-flow preparation of triazenes including the anticancer compounds dacarbazine and mitozolomide

    OpenAIRE

    Schotten, Christiane; Aldmairi, Abdul Hadi; Sagatov, Yerbol; Shepherd, Martyn; Browne, Duncan L.

    2016-01-01

    Herein, we report a continuous-flow process for the preparation of triazenes, whereby diazonium salts are generated and converted into their masked or protected triazene derivatives. Key to realizing the process, which is applicable to a wide range of substrates, is the identification of solvent and reagent parameters that avoid fouling and clogging in the tubing used in these studies. The process has also been applied to prepare the antineoplastic agents mitozolomide and dacarbazine. We also...

  20. Manganese-Catalyzed Aerobic Heterocoupling of Aryl Grignard Reagents

    DEFF Research Database (Denmark)

    Ghaleshahi, Hajar Golshahi; Antonacci, Giuseppe; Madsen, Robert

    2017-01-01

    An improved protocol has been developed for the MnCl2-catalyzed cross-coupling reaction of two arylmagnesium bromides under dioxygen. The reaction was achieved by using the Grignard reagents in a 2:1 ratio and 20 % of MnCl2. Very good yields of the heterocoupling product were obtained when the li...

  1. Effects of Fenton's Reagent on aquifer geochemistry and microbiology at the A/M Area, Savannah River Site

    International Nuclear Information System (INIS)

    Denham, M.

    2000-01-01

    This report details the results of an investigation of Site conditions following a successful 1997 demonstration of in-situ DNAPL destruction by injection of Fenton's Reagent (hydrogen peroxide and ferrous sulfate solution) into DNAPL-bearing zones of an aquifer

  2. Preparation of Rhodamine B Fluorescent Poly(methacrylic acid) Coated Gelatin Nanoparticles

    OpenAIRE

    Gan, Zhenhai; Ju, Jianhui; Zhang, Ting; Wu, Daocheng

    2011-01-01

    Poly(methacrylic acid) (PMAA)-coated gelatin nanoparticles encapsulated with fluorescent dye rhodamine B were prepared by the coacervation method with the aim to retard the release of rhodamine B from the gelatin matrix. With sodium sulfate as coacervation reagent for gelatin, a kind of biopolymer with excellent biocompatibility, the formed gelatin nanoparticles were cross-linked by formaldehyde followed by the polymerization of methacrylic acid coating. The fluorescent poly(methacrylic acid)...

  3. Two-dimensional parallel array technology as a new approach to automated combinatorial solid-phase organic synthesis

    Science.gov (United States)

    Brennan; Biddison; Frauendorf; Schwarcz; Keen; Ecker; Davis; Tinder; Swayze

    1998-01-01

    An automated, 96-well parallel array synthesizer for solid-phase organic synthesis has been designed and constructed. The instrument employs a unique reagent array delivery format, in which each reagent utilized has a dedicated plumbing system. An inert atmosphere is maintained during all phases of a synthesis, and temperature can be controlled via a thermal transfer plate which holds the injection molded reaction block. The reaction plate assembly slides in the X-axis direction, while eight nozzle blocks holding the reagent lines slide in the Y-axis direction, allowing for the extremely rapid delivery of any of 64 reagents to 96 wells. In addition, there are six banks of fixed nozzle blocks, which deliver the same reagent or solvent to eight wells at once, for a total of 72 possible reagents. The instrument is controlled by software which allows the straightforward programming of the synthesis of a larger number of compounds. This is accomplished by supplying a general synthetic procedure in the form of a command file, which calls upon certain reagents to be added to specific wells via lookup in a sequence file. The bottle position, flow rate, and concentration of each reagent is stored in a separate reagent table file. To demonstrate the utility of the parallel array synthesizer, a small combinatorial library of hydroxamic acids was prepared in high throughput mode for biological screening. Approximately 1300 compounds were prepared on a 10 μmole scale (3-5 mg) in a few weeks. The resulting crude compounds were generally >80% pure, and were utilized directly for high throughput screening in antibacterial assays. Several active wells were found, and the activity was verified by solution-phase synthesis of analytically pure material, indicating that the system described herein is an efficient means for the parallel synthesis of compounds for lead discovery. Copyright 1998 John Wiley & Sons, Inc.

  4. ON-Line Monitoring of Instrument Channel Performance: Volume 3: Applications to Nuclear Power Plant Technical Specification Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    E Davis, B Rasmussen

    2004-12-31

    This report is a guide for a technical specification change submittal and subsequent implementation of on-line monitoring for safety-related applications. This report is the third in a three-volume set. Volume 1, ''Guidelines for Model Development and Implementation'', presents the various tasks that must be completed to prepare models for and to implement an on-line monitoring system.

  5. Use of new ceramic linings in coal preparation plants

    Energy Technology Data Exchange (ETDEWEB)

    Fedorchenko, V.E.; Rudenko, V.A.; Bondarev, A.Ya.

    1984-01-01

    This article evaluates several materials used as liners in coal preparation equipment. The evaluations concentrate on liners used under conditions of intensive temperature fluctuations, e.g. liners of coal chutes for coal transport from coal dryers. Two aspects of wear are analyzed: abrasion by friction and effects of temperature fluctuations. Abrasive wear is tested using magnetite suspension with a density of 400 g/l. Tests show that abrasive wear of liners on an alumina basis is 3 times lower than abrasive wear of high quality steel, from 13 to 24 times lower than that of iron and from 6 to 8 times lower than that of steels used in coal preparation plants. Effects of temperature fluctuations from 20 to 840 C on abrasive wear of liners of steels, iron, slag glass ceramics, mullite-corundum material and corundum is shown in a table. The test show that mullite-corundum material on the basis of alumina is characterized by a high resistance to abrasive wear after 30 cycles of temperature increase from 20 to 840 C and decrease to 20 C. Using mullite-corundum as liners of equipment and installations operating under conditions of temperature fluctuations is recommended.

  6. Effects of latent fingerprint development reagents on subsequent forensic DNA typing: a review.

    Science.gov (United States)

    Kumar, Parveen; Gupta, Ritika; Singh, Rajinder; Jasuja, Om Prakash

    2015-05-01

    Successful development of latent fingerprints can be helpful in solving the case but in case where fingerprints are smudged, distorted or overlapped, the question arises whether it is still possible to identify the person apart from dermatoglyphic features. Sweat residue present in the latent prints is supposed to have quite good quantity of cellular material which if analyzed properly can be used to generate forensic DNA profile of the individual and may answer the queries related to the effect of reagents used to develop the prints, as they may have a significant effect on the process of examination of this evidentiary material. In the present work an effort has been made to summarize the published review of literature on this aspect of personal identification. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  7. Antiproliferative effects of small fruit juices on several cancer cell lines.

    Science.gov (United States)

    Yoshizawa, Y; Kawaii, S; Urashima, M; Fukase, T; Sato, T; Tanaka, R; Murofushi, N; Nishimura, H

    2000-01-01

    Juices prepared from small fruits, mainly growing in the northern part of Japan, were studied in an attempt to explore the feasibility of an assay that screens cytotoxic properties. Screening of 43 small fruit juices indicated that Actinidia polygama Maxim., Rosa rugosa Thunb., Vaccinium smallii A. Gray and Sorbus sambucifolia Roem, strongly inhibited the proliferation of all cancer cell lines examined and yet these juices were substantially less cytotoxic toward normal human cell lines.

  8. 2006 Bethesda International Consensus recommendations on the immunophenotypic analysis of hematolymphoid neoplasia by flow cytometry: optimal reagents and reporting for the flow cytometric diagnosis of hematopoietic neoplasia.

    Science.gov (United States)

    Wood, Brent L; Arroz, Maria; Barnett, David; DiGiuseppe, Joseph; Greig, Bruce; Kussick, Steven J; Oldaker, Teri; Shenkin, Mark; Stone, Elizabeth; Wallace, Paul

    2007-01-01

    Immunophenotyping by flow cytometry has become standard practice in the evaluation and monitoring of patients with hematopoietic neoplasia. However, despite its widespread use, considerable variability continues to exist in the reagents used for evaluation and the format in which results are reported. As part of the 2006 Bethesda Consensus conference, a committee was formed to attempt to define a consensus set of reagents suitable for general use in the diagnosis and monitoring of hematopoietic neoplasms. The committee included laboratory professionals from private, public, and university hospitals as well as large reference laboratories that routinely operate clinical flow cytometry laboratories with an emphasis on lymphoma and leukemia immunophenotyping. A survey of participants successfully identified the cell lineage(s) to be evaluated for each of a variety of specific medical indications and defined a set of consensus reagents suitable for the initial evaluation of each cell lineage. Elements to be included in the reporting of clinical flow cytometric results for leukemia and lymphoma evaluation were also refined and are comprehensively listed. The 2006 Bethesda Consensus conference represents the first successful attempt to define a set of consensus reagents suitable for the initial evaluation of hematopoietic neoplasia. Copyright 2007 Clinical Cytometry Society.

  9. Tratamento de água subterrânea contaminada com compostos organoclorados usando ferro elementar e o reagente de Fenton Treatment of groundwater contaminated with chlorinated compounds using elemental iron and Fenton's reagent

    Directory of Open Access Journals (Sweden)

    Tatiana Langbeck de Arruda

    2007-01-01

    Full Text Available The remediation of groundwater containing organochlorine compounds was evaluated using a reductive system with zero-valent iron, and the reductive process coupled with Fenton's reagent. The concentration of the individual target compounds reached up to 400 mg L-1 in the sample. Marked reductions in the chlorinated compounds were observed in the reductive process. The degradation followed pseudo-first-order kinetics in terms of the contaminant and was dependent on the sample contact time with the solid reducing agent. An oxidative test with Fenton's reagent, followed by the reductive assay, showed that tetrachloroethylene was further reduced up to three times the initial concentration. The destruction of chloroform, however, demands an additional treatment.

  10. Comparison of vacuum metal deposition and 1,2-indandione/ninhydrin reagent method for the development of fingerprints on renminbi

    Directory of Open Access Journals (Sweden)

    Cong Wang

    2017-01-01

    Full Text Available It is extremely difficult to develop fingerprints from the surface of currency. There are studies reporting that the high vacuum metal deposition (VMD method can be used to detect fingerprints on certain types of currency notes. Both VMD and 1,2-indandione/ninhydrin techniques are employed to visualize latent fingermarks on porous surfaces, such as paper. The current study explores whether the VMD method or 1,2-indandione/ninhydrin reagent method is more effective in the development of fingerprints on renminbi (RMB. Uncirculated, circulated, and water-exposed RMB was utilized in this study, along with five donors who ranged in their age and potential to leave fingermarks. Samples were aged for a determined period (for uncirculated and circulated RMB, times were 1, 3, 5, 10, and 35 days; for water-exposed RMB, exposure time was 1 day and then treated with VMD and 1,2-indandione/ninhydrin. The results suggested that the 1,2-indandione/ninhydrin reagent yielded a better effect for both circulated and uncirculated RMB. For the RMB exposed to water, VMD performed better and gave limited results in terms of fingerprint development, which could serve as a reference for actual forensic cases.

  11. Treatment of landfill leachate by Fenton's reagent in a continuous stirred tank reactor

    International Nuclear Information System (INIS)

    Zhang Hui; Choi, H.J.; Huang, C.-P.

    2006-01-01

    The treatment of landfill leachate by Fenton process was carried out in a continuous stirred tank reactor (CSTR). The effect of operating conditions such as reaction time, hydraulic retention time, pH, H 2 O 2 to Fe(II) molar ratio, Fenton's reagent dosage, initial COD strength, and temperature on the efficacy of Fenton process was investigated. It is demonstrated that Fenton's reagent can effectively degrade leachate organics. Fenton process reached the steady state after three times of hydraulic retention. The oxidation of organic materials in the leachate was pH dependent and the optimal pH was 2.5. The favorable H 2 O 2 to Fe(II) molar ratio was 3, and organic removal increased as dosage increased at the favorable H 2 O 2 to Fe(II) molar ratio. Temperature gave a positive effect on organic removal

  12. ETAC reagents: A new class of sulfhydryl site-specific radiolabelling probes for antibodies

    International Nuclear Information System (INIS)

    del Rosario, R.B.; Brocchini, S.J.; Baron, L.A.; Smith, R.H.; Lawton, R.G.; Wahl, R.L.

    1990-01-01

    A new class of bis-alkylating Michael reagents, equilibrium transfer crosslink reagents, 'ETAC', which combine the techniques of crosslinking with tethering have been synthesized. Following a succession of Michael and retro-Michael additions and elimination of the arylsulfone groups, reduced heavy-heavy and heavy-light disulfide links of an anti-ovarian IgG2a monoclonal antibody, 5G6.4, were site-specifically re-annealed via a 3-carbon bridge having a tether branch containing a designated label

  13. Preparation of Proper Immunogen by Cloning and Stable Expression of cDNA coding for Human Hematopoietic Stem Cell Marker CD34 in NIH-3T3 Mouse Fibroblast Cell Line

    Science.gov (United States)

    Shafaghat, Farzaneh; Abbasi-Kenarsari, Hajar; Majidi, Jafar; Movassaghpour, Ali Akbar; Shanehbandi, Dariush; Kazemi, Tohid

    2015-01-01

    Purpose: Transmembrane CD34 glycoprotein is the most important marker for identification, isolation and enumeration of hematopoietic stem cells (HSCs). We aimed in this study to clone the cDNA coding for human CD34 from KG1a cell line and stably express in mouse fibroblast cell line NIH-3T3. Such artificial cell line could be useful as proper immunogen for production of mouse monoclonal antibodies. Methods: CD34 cDNA was cloned from KG1a cell line after total RNA extraction and cDNA synthesis. Pfu DNA polymerase-amplified specific band was ligated to pGEMT-easy TA-cloning vector and sub-cloned in pCMV6-Neo expression vector. After transfection of NIH-3T3 cells using 3 μg of recombinant construct and 6 μl of JetPEI transfection reagent, stable expression was obtained by selection of cells by G418 antibiotic and confirmed by surface flow cytometry. Results: 1158 bp specific band was aligned completely to reference sequence in NCBI database corresponding to long isoform of human CD34. Transient and stable expression of human CD34 on transfected NIH-3T3 mouse fibroblast cells was achieved (25% and 95%, respectively) as shown by flow cytometry. Conclusion: Cloning and stable expression of human CD34 cDNA was successfully performed and validated by standard flow cytometric analysis. Due to murine origin of NIH-3T3 cell line, CD34-expressing NIH-3T3 cells could be useful as immunogen in production of diagnostic monoclonal antibodies against human CD34. This approach could bypass the need for purification of recombinant proteins produced in eukaryotic expression systems. PMID:25789221

  14. The role of graphene-based sorbents in modern sample preparation techniques.

    Science.gov (United States)

    de Toffoli, Ana Lúcia; Maciel, Edvaldo Vasconcelos Soares; Fumes, Bruno Henrique; Lanças, Fernando Mauro

    2018-01-01

    The application of graphene-based sorbents in sample preparation techniques has increased significantly since 2011. These materials have good physicochemical properties to be used as sorbent and have shown excellent results in different sample preparation techniques. Graphene and its precursor graphene oxide have been considered to be good candidates to improve the extraction and concentration of different classes of target compounds (e.g., parabens, polycyclic aromatic hydrocarbon, pyrethroids, triazines, and so on) present in complex matrices. Its applications have been employed during the analysis of different matrices (e.g., environmental, biological and food). In this review, we highlight the most important characteristics of graphene-based material, their properties, synthesis routes, and the most important applications in both off-line and on-line sample preparation techniques. The discussion of the off-line approaches includes methods derived from conventional solid-phase extraction focusing on the miniaturized magnetic and dispersive modes. The modes of microextraction techniques called stir bar sorptive extraction, solid phase microextraction, and microextraction by packed sorbent are discussed. The on-line approaches focus on the use of graphene-based material mainly in on-line solid phase extraction, its variation called in-tube solid-phase microextraction, and on-line microdialysis systems. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Peptide bond-forming reagents HOAt and HATU are not mutagenic in the bacterial reverse mutation test.

    Science.gov (United States)

    Nicolette, John; Neft, Robin E; Vanosdol, Jessica; Murray, Joel

    2016-04-01

    The peptide bond-forming reagents 1-hydroxy-7-azabenzotriazole (HOAt, CAS 39968-33-7) and O-(7-Azabenzotriazol-1-yl)-N,N,N',N'-tetramethyluronium hexafluorophosphate (HATU, CAS 148893-10-1) either have structural alerts, unclassified features or are considered out of domain when evaluated for potential mutagenicity with in silico programs DEREK and CaseUltra. Since they are commonly used reagents in pharmaceutical drug syntheses, they may become drug substance or drug product impurities and would need to be either controlled to appropriately safe levels or tested for mutagenicity. Both reagents were tested in the bacterial reverse mutation (Ames) test at Covance, under GLP conditions, following the OECD test guideline and ICH S2(R1) recommendations and found to be negative. Our data show that HOAt and HATU-common pharmaceutical synthesis reagents-are not mutagenic, and can be treated as ordinary drug impurities. © 2016 Wiley Periodicals, Inc.

  16. SATL Based Lesson for Teaching Grignard Reagents in Synthetic ...

    African Journals Online (AJOL)

    Synthesizing new products from raw materials has been very popular aspects of research in organic chemistry. Traditionally, Grignard reagent has been very vital component of such synthetic procedures. Hence learning of various issues concerning with applications of Grignard reactions in synthetic organic chemistry is ...

  17. Construction of a Liposome Dialyzer for preparation of high-value, small-volume liposome formulations

    Science.gov (United States)

    Adamala, Katarzyna; Engelhart, Aaron E.; Kamat, Neha P.; Jin, Lin; Szostak, Jack W.

    2016-01-01

    The liposome dialyzer is a small-volume equilibrium dialysis device, built from commercially available materials, that is designed for rapid exchange of small volumes of an extraliposomal reagent pool against a liposome preparation. The dialyzer is prepared by modification of commercially available dialysis cartridges and consists of a reactor with two 300 µL chambers and a 1.56 cm2 dialysis surface area. The dialyzer is prepared in three stages: 1) disassembly of dialysis cartridges to obtain required parts; 2) assembly of the dialyzer; and 3) sealing the dialyzer with epoxy. Preparation of the dialyser takes about 1.5 h, not including overnight epoxy curing. Each round of dialysis takes 1–24 h, depending on the analyte and membrane employed. We previously used the dialyzer for small-volume nonenzymatic RNA synthesis reactions inside fatty acid vesicles. In this protocol, we demonstrate other applications, including removal of unencapsulated calcein from vesicles, remote loading, and vesicle microscopy. PMID:26020615

  18. Optimization Of Preparation And Validation Of Hepatitis C Irma Kit

    International Nuclear Information System (INIS)

    Ariyanto, Agus; Wayan, R.S.; Sukiyati, Dj.; Darwati, Siti; Yunita, Fitri; Mondrida, Gina; Sulaiman; Yulianti, Veronika; Setiowati, Sri

    2000-01-01

    Optimization of preparation and validation of hepatitis C IRMA kit have been done. Tracer was prepared by iodination of anti-hlgG with 125 I using Choramin-T and N-Bromosuksinimide as oxidizing agent. Iodinated anti-hlgG was purified using PD-10 and Sephadex G-50 column. Coated bead was prepared by immobilization of antigen HCV recombinant on polystyrene bead. To obtain a good quality of reagent some parameters were optimized i.e.: colim used for purification. To determine the validity of the kit, validation which include comparison study and determination of specificity and sensitivity have been performed. A good quality of tracer has been able to prepared with high yield (74%) and high P/N value (15). The quality of coated bead is also reasonably good (P/N 34.3), and gave a good density and dissociation index (0.335 and 0.99% respectively). Both tracer and coated bead were remain stable after 2 months storage at 4 o C. In comparison with Elisa kit, the specificity and sensitivity of the HCV IRMA kit is reasonably high, 88.6% and 92.3% respectively

  19. Evaluation of Enoyl-Acyl Carrier Protein Reductase Inhibitors as Pseudomonas aeruginosa Quorum-Quenching Reagents

    DEFF Research Database (Denmark)

    Yang, Liang; Liu, Yang; Sternberg, Claus

    2010-01-01

    Pseudomonas aeruginosa is an opportunistic pathogen which is responsible for a wide range of infections. Production of virulence factors and biofilm formation by P. aeruginosa are partly regulated by cell-to-cell communication quorum-sensing systems. Identification of quorum-quenching reagents...... which block the quorum-sensing process can facilitate development of novel treatment strategies for P. aeruginosa infections. We have used molecular dynamics simulation and experimental studies to elucidate the efficiencies of two potential quorum-quenching reagents, triclosan and green tea...... epigallocatechin gallate (EGCG), which both function as inhibitors of the enoyl-acyl carrier protein (ACP) reductase (ENR) from the bacterial type II fatty acid synthesis pathway. Our studies suggest that EGCG has a higher binding affinity towards ENR of P. aeruginosa and is an efficient quorum-quenching reagent...

  20. Preparation of sup 125 I-creatine phosphokinase-MM

    Energy Technology Data Exchange (ETDEWEB)

    Jingxian, Su; Jingmin, Ma [Academia Sinica, Beijing, BJ (China). Inst. of Atomic Energy

    1988-09-01

    {sup 125}I-creatine phosphokinase-MM ({sup 125}I-CPK-MM) was prepared by {sup 125}I-labelled Bolton-Hunter reagent (HPNS). Iodinating conditions of HPNS and its conjugation to protein were studied. {sup 125}I-CPK-MM with immune activity was obtained and used to establish the {sup 125}I-CPK-MM radioimmunoassay method by the General Hospital of PLA. {sup 125}I-CPK-MM in PBS-G solution containing 0.015 mol/l ethyl mercaptan at 4-10 deg C can be used for one month.

  1. Reliability of Reagent Strips for Semi-quantitative Measurement of Glucosuria in a Neonatal Intensive Care Setting

    Directory of Open Access Journals (Sweden)

    Jolita Bekhof

    2014-12-01

    Conclusion: The reliability of the semi-quantitative measurement of glucosuria in newborn infants using reagent strips is good, even under the conditions of a NICU. Changes in the rating of reagent strips of more than one category are most likely to be beyond measurement error.

  2. 75 FR 4619 - Intent to Prepare an Environmental Impact Statement on Transportation Improvements Within the...

    Science.gov (United States)

    2010-01-28

    ... the constraints placed on it by RTA's financial capacities. Financial plans are suggesting that RTA... Impact Statement on Transportation Improvements Within the Blue-Line Corridor in Shaker Heights and... Transportation. ACTION: Notice of Intent to prepare an Environmental Impact Statement. SUMMARY: The Federal...

  3. Green approaches in sample preparation of bioanalytical samples prior to chromatographic analysis.

    Science.gov (United States)

    Filippou, Olga; Bitas, Dimitrios; Samanidou, Victoria

    2017-02-01

    Sample preparation is considered to be the most challenging step of the analytical procedure, since it has an effect on the whole analytical methodology, therefore it contributes significantly to the greenness or lack of it of the entire process. The elimination of the sample treatment steps, pursuing at the same time the reduction of the amount of the sample, strong reductions in consumption of hazardous reagents and energy also maximizing safety for operators and environment, the avoidance of the use of big amount of organic solvents, form the basis for greening sample preparation and analytical methods. In the last decade, the development and utilization of greener and sustainable microextraction techniques is an alternative to classical sample preparation procedures. In this review, the main green microextraction techniques (solid phase microextraction, stir bar sorptive extraction, hollow-fiber liquid phase microextraction, dispersive liquid - liquid microextraction, etc.) will be presented, with special attention to bioanalytical applications of these environment-friendly sample preparation techniques which comply with the green analytical chemistry principles. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Selenium and tellurium reagents in organic synthesis

    International Nuclear Information System (INIS)

    Comasseto, J.V.

    1984-01-01

    A review of the contribution of the University of Sao Paulo (SP, Brazil) to the organic synthesis of selenium and tellurium reagents is made. Major reactions amoung selenium compounds and insaturated substrates, phosphorus, ester enolates as well as the use of phase transference catalysed reactions to produce arylselenolate are described. For tellurium, interactions of its compounds with organic substrates and reactive intermediates (e.g. benzino diazomethane) are reported. (C.L.B.) [pt

  5. Effect of reagent parameters on recovery of South Africa uranium ore

    Energy Technology Data Exchange (ETDEWEB)

    Afolabi, A.S., E-mail: afolaas@unisa.ac.za [Univ. of South Africa, Dept. of Civil and Chemical Engineering, Johannesburg (South Africa); Muzenda, E. [Univ. of Johannesburg, Chemical Engineering Technology Dept., Johannesburg (South Africa); Sigwadi, R. [SGS Lakefield Research Africa (Pty) Ltd., Johannesburg (South Africa)

    2010-07-01

    The effects of leach parameters to determine the variability of reagents consumption on a uranium ore was investigated in this work. The effects of time, temperature sulphates, and acid consumption on the rate of dissolution of the comminuted uranium ore samples were also studied. It was found that 77% dissolution of uranium was achieved after 8 hours while maximum uranium leaching of 92% was achieved at temperature 30{sup o}C for 1 hour. The addition of ferric sulphate at 30{sup o}C showed a decrease in acid consumption from 79.32 kg/t to 32.32 kg/t as well as decrease in the MnO{sub 2} consumption from 21.03 kg/t to 15.06 kg/t. At elevated temperature of 6{sup o}C a higher acid consumption of 100 kg/t was obtained and this is attributed to the fact that other acid consuming minerals were leached at this temperature. Maximum uranium dissolution of 89.37% was achieved after 24 hours and the acid consumption was 31 kg/t with a MnO{sub 2} addition of 24.26 kg/t. (author)

  6. Spatial and Temporal Control of Cavitation Allows High In Vitro Transfection Efficiency in the Absence of Transfection Reagents or Contrast Agents

    Science.gov (United States)

    Chettab, Kamel; Roux, Stéphanie; Mathé, Doriane; Cros-Perrial, Emeline; Lafond, Maxime; Lafon, Cyril; Dumontet, Charles; Mestas, Jean-Louis

    2015-01-01

    Sonoporation using low-frequency high-pressure ultrasound (US) is a non-viral approach for in vitro and in vivo gene delivery. In this study, we developed a new sonoporation device designed for spatial and temporal control of ultrasound cavitation. The regulation system incorporated in the device allowed a real-time control of the cavitation level during sonoporation. This device was evaluated for the in vitro transfection efficiency of a plasmid coding for Green Fluorescent Protein (pEGFP-C1) in adherent and non-adherent cell lines. The transfection efficiency of the device was compared to those observed with lipofection and nucleofection methods. In both adherent and non-adherent cell lines, the sonoporation device allowed high rate of transfection of pEGFP-C1 (40–80%), as determined by flow cytometry analysis of GFP expression, along with a low rate of mortality assessed by propidium iodide staining. The transfection efficiency and toxicity of sonoporation on the non-adherent cell lines Jurkat and K562 were similar to those of nucleofection, while these two cell lines were resistant to transfection by lipofection. Moreover, sonoporation was used to produce three stably transfected human lymphoma and leukemia lines. Significant transfection efficiency was also observed in two fresh samples of human acute myeloid leukemia cells. In conclusion, we developed a user-friendly and cost-effective ultrasound device, well adapted for routine in vitro high-yield transfection experiments and which does not require the use of any transfection reagent or gas micro-bubbles. PMID:26274324

  7. Spatial and Temporal Control of Cavitation Allows High In Vitro Transfection Efficiency in the Absence of Transfection Reagents or Contrast Agents.

    Directory of Open Access Journals (Sweden)

    Kamel Chettab

    Full Text Available Sonoporation using low-frequency high-pressure ultrasound (US is a non-viral approach for in vitro and in vivo gene delivery. In this study, we developed a new sonoporation device designed for spatial and temporal control of ultrasound cavitation. The regulation system incorporated in the device allowed a real-time control of the cavitation level during sonoporation. This device was evaluated for the in vitro transfection efficiency of a plasmid coding for Green Fluorescent Protein (pEGFP-C1 in adherent and non-adherent cell lines. The transfection efficiency of the device was compared to those observed with lipofection and nucleofection methods. In both adherent and non-adherent cell lines, the sonoporation device allowed high rate of transfection of pEGFP-C1 (40-80%, as determined by flow cytometry analysis of GFP expression, along with a low rate of mortality assessed by propidium iodide staining. The transfection efficiency and toxicity of sonoporation on the non-adherent cell lines Jurkat and K562 were similar to those of nucleofection, while these two cell lines were resistant to transfection by lipofection. Moreover, sonoporation was used to produce three stably transfected human lymphoma and leukemia lines. Significant transfection efficiency was also observed in two fresh samples of human acute myeloid leukemia cells. In conclusion, we developed a user-friendly and cost-effective ultrasound device, well adapted for routine in vitro high-yield transfection experiments and which does not require the use of any transfection reagent or gas micro-bubbles.

  8. THE USE OF GRIGNARD REAGENT IN PHEROMONE SYNTHESIS FOR PALM WEEVIL (Rhynchorus, Sp

    Directory of Open Access Journals (Sweden)

    Warsito Warsito

    2010-06-01

    Full Text Available In an integrated controlling system of palm weevil, using of synthetic feromoid is strickly needed. The research is aimed to synthesize pheromone which secreted by the weevil, e.g. 4-methyl-5-nonanol (R. ferrugineus and 3-methyl-4-octanol (R. schach through Grignard reagent which formed in situ. The synthesis was proceded by retrosynthesis to determine the precursor, valeraldehyde. The precursor was reacted with Grignard reagent of sec-amyl magnesium bromide (R. ferrugenieus and sec-butyl magnesium bromide (R. shach which made in situ. Characterization of the synthetic molecular pheromone was performed by Gas Chromatography-mass spectroscopy and Fourier Transformed Infra Red. The bioassay of the molecule was carried out by olfactometer. The result showed that the conversion of the reactions were 51.28% (4-methyl-5-nonanol and 85.90% (3-methyl-4-octanol. The character of physico-chemical and bioactivity of the synthetic pheromone are identic with natural pheromones.   Keywords: palm weevil, pheromone, grignard reagent

  9. Worst-case study for cleaning validation of equipment in the radiopharmaceutical production of lyophilized reagents: Methodology validation of total organic carbon

    International Nuclear Information System (INIS)

    Porto, Luciana Valeria Ferrari Machado

    2015-01-01

    Radiopharmaceuticals are defined as pharmaceutical preparations containing a radionuclide in their composition, mostly intravenously administered, and therefore compliance with the principles of Good Manufacturing Practices (GMP) is essential and indispensable. Cleaning validation is a requirement of the current GMP, and consists of documented evidence, which demonstrates that the cleaning procedures are able to remove residues to pre-determined acceptance levels, ensuring that no cross contamination occurs. A simplification of cleaning processes validation is accepted, and consists in choosing a product, called 'worst case', to represent the cleaning processes of all equipment of the same production area. One of the steps of cleaning validation is the establishment and validation of the analytical method to quantify the residue. The aim of this study was to establish the worst case for cleaning validation of equipment in the radiopharmaceutical production of lyophilized reagent (LR) for labeling with 99m Tc, evaluate the use of Total Organic Carbon (TOC) content as indicator of equipment cleaning used in the LR manufacture, validate the method of Non-Purgeable Organic Carbon (NPOC), and perform recovery tests with the product chosen as worst case. Worst case product's choice was based on the calculation of an index called 'Worst Case Index' (WCI), using information about drug solubility, difficulty of cleaning the equipment and occupancy rate of the products in line production. The products indicated 'worst case' was the LR MIBI-TEC. The method validation assays were performed using carbon analyser model TOC-Vwp coupled to an autosampler model ASI-V, both from Shimadzu®, controlled by TOC Control-V software. It was used the direct method for NPOC quantification. The parameters evaluated in the validation method were: system suitability, robustness, linearity, detection limit (DL) and quantification limit (QL), precision

  10. On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber

    CERN Document Server

    Bianchi, F; Mathot, S; Baltensperger, U

    2012-01-01

    A new instrument for the on-line determination of ammonia was developed. Since ammonia is a rather sticky compound, sampling losses were minimised with a new sam- pling device where the ammonia was transferred to the liq- uid phase only 5 mm after the inlet tip. The liquid phase was then analyzed by long pathlength absorption spectrophotom- etry using the Berthelot reaction with phenol and hypochlo- rite as reagents. The measurements were made during the CLOUD3 campaign at CERN where the influence of ammo- nia on the nucleation rate was studied. At stable conditions the detection limit reached with this instrument was 35 pptv (air flow rate of 2 l min − 1 , liquid flow rate of 0.3 ml min − 1 ), although occasionally the instrument was affected by back- ground problems. The range of mixing ratios during this campaign was varied from the background contamination ( < 35 pptv) up to around 2 ppbv. The measured ammonia concentration was correlated with the rate of ammonia in- jected into the chamber, but wi...

  11. FI/SI on-line solvent extraction/back extraction preconcentration coupled to direct injection nebulization inductively coupled plasma mass spectrometry for determination of copper and lead

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    An automated sequential injection on-line preconcentration procedure for determination of trace levels of copper and lead via solvent extraction/back extraction coupled to ICP-MS is described. In citrate buffer of pH 3, neutral complexes between the analytes and the chelating reagent, ammonium...... loop, the content of which is subsequently introduced into the ICP-MS, via a direct injection high efficiency nebulizer (DIHEN), for quantification. Enrichment factors of 29.6 (Cu) and 23.3 (Pb), detection limits of 17 ng/l (Cu) and 11 ng/l (Pb), along with a sampling frequency of 13 s/h were obtained...

  12. Influence of surface melting effects and availability of reagent ions on LDI-MS efficiency after UV laser irradiation of Pd nanostructures.

    Science.gov (United States)

    Silina, Yuliya E; Koch, Marcus; Volmer, Dietrich A

    2015-03-01

    In this study, the influence of surface morphology, reagent ions and surface restructuring effects on atmospheric pressure laser desorption/ionization (LDI) for small molecules after laser irradiation of palladium self-assembled nanoparticular (Pd-NP) structures has been systematically studied. The dominant role of surface morphology during the LDI process, which was previously shown for silicon-based substrates, has not been investigated for metal-based substrates before. In our experiments, we demonstrated that both the presence of reagent ions and surface reorganization effects--in particular, melting--during laser irradiation was required for LDI activity of the substrate. The synthesized Pd nanostructures with diameters ranging from 60 to 180 nm started to melt at similar temperatures, viz. 890-898 K. These materials exhibited different LDI efficiencies, however, with Pd-NP materials being the most effective surface in our experiments. Pd nanostructures of diameters >400-800 nm started to melt at higher temperatures, >1000 K, making such targets more resistant to laser irradiation, with subsequent loss of LDI activity. Our data demonstrated that both melting of the surface structures and the presence of reagent ions were essential for efficient LDI of the investigated low molecular weight compounds. This dependence of LDI on melting points was exploited further to improve the performance of Pd-NP-based sampling targets. For example, adding sodium hypophosphite as reducing agent to Pd electrolyte solutions during synthesis lowered the melting points of the Pd-NP materials and subsequently gave reduced laser fluence requirements for LDI. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Flotation of copper-bearing shale in solutions of inorganic salts and organic reagents

    Directory of Open Access Journals (Sweden)

    Ratajczak Tomasz

    2017-01-01

    Full Text Available Flotation data on copper-bearing shale in aqueous solutions of inorganic electrolytes (NaCl, Na2SO4, KPF6, NH4Cl and organic reagents (ethylamine, propylamine as frothers were presented and discussed. The relationships between shale flotation, surface tension of aqueous solution and foam height during bubbling with air in the flotation system were presented. It has been found that flotation of shale in the presence of inorganic salts the yield was directly proportional to the surface tension of the aqueous solution of salt and inversely proportional to the height of the foam. On the other hand, for organic reagents solutions (short chain amines, a reverse effect has been observed in relation to the inorganic compounds studied, that is the yield of copper-bearing shale flotation and the foam height were inversely proportional to the surface tension of the amine solution.

  14. Reaction of lupane and oleanane triterpenoids with Lawesson's reagent

    Czech Academy of Sciences Publication Activity Database

    Kvasnica, Miroslav; Rudovská, I.; Císařová, I.; Šarek, J.

    2008-01-01

    Roč. 64, č. 17 (2008), s. 3736-3743 ISSN 0040-4020 Grant - others:GA ČR(CZ) GP203/05/P025 Institutional research plan: CEZ:AV0Z40550506 Keywords : terpenoids * Lawesson's reagent * ketones * sulfur Subject RIV: CC - Organic Chemistry Impact factor: 2.897, year: 2008

  15. Simultaneous in-line concentration for spectrophotometric determination of cations and anions

    Directory of Open Access Journals (Sweden)

    Rocha Fábio R. P

    2004-01-01

    Full Text Available A flow system is proposed for simultaneous in-line concentration of cations and anions. A sliding-bar commutator was employed to insert an anion and a cation exchange column into a flowing sample stream for serial retention of the analytes. In the injector alternative position, different solutions flowed through the columns for parallel elution of the species in different analytical paths. Three-way solenoid valves allowed the intermittent reagent introduction in the sample zones. Signals were measured by employing two flow-through LED-based detectors. The simultaneous retention of the sample zones in coiled reactors can be also performed to increase the residence time and the analyte conversion rate. The analytical potentiality was demonstrated by the in-line concentration of ammonium and phosphate followed by spectrophotometric detection. For a 90 s loading time, the sampling rate was estimated as 40 determinations per hour, which is three-fold higher than the obtained without performing the tasks simultaneously. Enrichment factors of 8.0 and 18 were estimated for phosphate and ammonium, respectively, yielding detection limits of 1 mg L-1 PO4(3- and 1 mg L-1 NH4+ (99.7% confidence level. The reagent consumption was lower than 2 mg per determination. Results for freshwater samples agreed with the obtained by reference APHA procedures at the 95% confidence level.

  16. Effect of complexing reagents on the ionization constant of boric acid and its relation to isotopic exchange separation factor

    International Nuclear Information System (INIS)

    Sharma, B.K.; Subramanian, R.; Mathur, P.K.

    1991-01-01

    The effect of change in concentration of complexing reagents having two or more hydroxyl groups, viz., ethylene glycol, propylene glycol, dextrose and mannitol on the ionization constant of boric acid has been studied by pH-metric titration method. The effect of increase in ionization constant of boric acid on isotopic exchange separation factor for the separation of isotopes of boron by ion exchange chromatography has been studied by the batch method. (author). 9 refs

  17. Evaluation of three sample preparation methods for the direct identification of bacteria in positive blood cultures by MALDI-TOF

    OpenAIRE

    Tanner, Hannah; Evans, Jason T.; Gossain, Savita; Hussain, Abid

    2017-01-01

    Background Patient mortality is significantly reduced by rapid identification of bacteria from sterile sites. MALDI-TOF can identify bacteria directly from positive blood cultures and multiple sample preparation methods are available. We evaluated three sample preparation methods and two MALDI-TOF score cut-off values. Positive blood culture bottles with organisms present in Gram stains were prospectively analysed by MALDI-TOF. Three lysis reagents (Saponin, SDS, and SepsiTyper lysis bufer) w...

  18. Reagent-free bacterial identification using multivariate analysis of transmission spectra

    Science.gov (United States)

    Smith, Jennifer M.; Huffman, Debra E.; Acosta, Dayanis; Serebrennikova, Yulia; García-Rubio, Luis; Leparc, German F.

    2012-10-01

    The identification of bacterial pathogens from culture is critical to the proper administration of antibiotics and patient treatment. Many of the tests currently used in the clinical microbiology laboratory for bacterial identification today can be highly sensitive and specific; however, they have the additional burdens of complexity, cost, and the need for specialized reagents. We present an innovative, reagent-free method for the identification of pathogens from culture. A clinical study has been initiated to evaluate the sensitivity and specificity of this approach. Multiwavelength transmission spectra were generated from a set of clinical isolates including Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, and Staphylococcus aureus. Spectra of an initial training set of these target organisms were used to create identification models representing the spectral variability of each species using multivariate statistical techniques. Next, the spectra of the blinded isolates of targeted species were identified using the model achieving >94% sensitivity and >98% specificity, with 100% accuracy for P. aeruginosa and S. aureus. The results from this on-going clinical study indicate this approach is a powerful and exciting technique for identification of pathogens. The menu of models is being expanded to include other bacterial genera and species of clinical significance.

  19. Line-breaking algorithm enhancement in inverse typesetting paradigma

    Directory of Open Access Journals (Sweden)

    Jan Přichystal

    2007-01-01

    Full Text Available High quality text preparing using computer desktop publishing systems usually uses line-breaking algorithm which cannot make provision for line heights and typeset paragraph accurately when composition width, page break, line index or other object appears. This article deals with enhancing of line-breaking algorithm based on optimum-fit algorithm. This algorithm is enhanced with calculation of immediate typesetting width and thus solves problem of forced change. Line-breaking algorithm enhancement causes expansion potentialities of high-quality typesetting in cases that have not been yet covered with present typesetting systems.

  20. Nodalization Preparation for the Transient Simulation of Cooling System for One Line Mode of RSG-GAS

    International Nuclear Information System (INIS)

    Sukmanto Dibyo; Susyadi; Tagor MS; Darwis Isnaeni

    2004-01-01

    Cooling system is important component in RSG-GAS. To carry out the transient simulation of one line-cooling mode, the model of RSG-GAS has been prepared. To illustrate the transient condition, the RELAP5.MOD3 computer code the existing input files were used. This Input consist of kinetic, thermal, hydraulic and geometries data. Modification and decrement of number of nodalization has been done to simplification as well as running time. The reasonable result of model is arranged to determine the initial condition of input data therefore steady state condition have agreement to the analysis result of one line cooling mode of RSG-GAS. Parameter investigated are transient temperatures of cooling system after decreasing of secondary cooling system occur as function of time. These parameters can be requested using input of Minor Edit Request Simulation is conducted at the reactor power of 15 MW steady-state for one-line cooling mode in which the primary and secondary cooling of 430 kg/sec and 550 kg/sec respectively. Decreasing of secondary cooling flow is caused by pump trip. As a consequence, the control rod drop due to reactor protection system. The negative reactivity of control rod causes decreasing of reactor power. Change of pattern for the primary and secondary cooling system can be known. After that simulation depicts that increasing of temperatures occur at the certain moment since initiation temperature conditions, due to reactor shut down, curve inclined move going down. (author)

  1. Labelling of HBV-DNA probe using reagent made in China

    International Nuclear Information System (INIS)

    Wang Quanshi

    1991-01-01

    The labelling hepatitis Bvirus DNA (HBV-DNA) probe was studied by using reagent made in China. The results showed that: (1) The dNTPs with high specific activity was necessary for the labelling of nigh specific activity HBV-DNA probe; (2) reaction of labelling HBV-DNA probe was completed in a few minutes; (3) 0.37 MBq 3 H dTTP (specific activity 1.554TBq/mmol) was enough to label 1 μg HBV-DNA and the specific activity of probe reached 3.4 x 10 cpm/μg; (4) 7 MBqα- 32 P dATP (specific activity > 111 TBq/mmol) can label HBV-DNA probe to specific activity 1.35 x 10 cpm/μg. It was concluded that the reagent made in China can be used for the study in molecular biology

  2. Conjugate additions of a simple monosilylcopper reagent with use of the CuI.DMS complex: stereoselectivities and a dramatic impact by DMS.

    Science.gov (United States)

    Dambacher, Jesse; Bergdahl, Mikael

    2005-01-21

    Conjugate additions utilizing the simple monosilylcuprate reagent Li[PhMe2SiCuI] to alpha,beta-unsaturated carbonyl compounds are described. The presence of dimethyl sulfide (DMS), either as a component originating from the (CuI)4(DMS)3 complex or as a solvent added, has an amazing influence on both chemical yield and the level of diastereomeric ratio (dr) of the products. Gilman-type silylcyanocuprates {Li(Ph2MeSi)2Cu/LiCN} have previously been used to guarantee good results in conjugate addition reactions. External additives such as HMPA, tributylphosphine, or dialkylzinc are not necessary in conjunction with the simple Li[PhMe2SiCuI] reagent. It is demonstrated that the monosilylcuprate reagent with DMS as the solvent is very useful with sterically hindered (beta,beta-disubstituted) enones, and provides very high yields of the beta-silylated 1,4-addition products. Since there is no oligomerization problem associated with the simple monosilylcuprate reagent, this reagent should be considered as a very useful 1,4-silyl donor to enals, enones, and enoates in conjugate addition reactions.

  3. Construction of a liposome dialyzer for the preparation of high-value, small-volume liposome formulations.

    Science.gov (United States)

    Adamala, Katarzyna; Engelhart, Aaron E; Kamat, Neha P; Jin, Lin; Szostak, Jack W

    2015-06-01

    The liposome dialyzer is a small-volume equilibrium dialysis device, built from commercially available materials, that is designed for the rapid exchange of small volumes of an extraliposomal reagent pool against a liposome preparation. The dialyzer is prepared by modification of commercially available dialysis cartridges (Slide-A-Lyzer cassettes), and it consists of a reactor with two 300-μl chambers and a 1.56-cm(2) dialysis surface area. The dialyzer is prepared in three stages: (i) disassembling the dialysis cartridges to obtain the required parts, (ii) assembling the dialyzer and (iii) sealing the dialyzer with epoxy. Preparation of the dialyzer takes ∼1.5 h, not including overnight epoxy curing. Each round of dialysis takes 1-24 h, depending on the analyte and membrane used. We previously used the dialyzer for small-volume non-enzymatic RNA synthesis reactions inside fatty acid vesicles. In this protocol, we demonstrate other applications, including removal of unencapsulated calcein from vesicles, remote loading and vesicle microscopy.

  4. Proficiency Testing for Determination of Water Content in Toluene of Chemical Reagents by iteration robust statistic technique

    Science.gov (United States)

    Wang, Hao; Wang, Qunwei; He, Ming

    2018-05-01

    In order to investigate and improve the level of detection technology of water content in liquid chemical reagents of domestic laboratories, proficiency testing provider PT0031 (CNAS) has organized proficiency testing program of water content in toluene, 48 laboratories from 18 provinces/cities/municipals took part in the PT. This paper introduces the implementation process of proficiency testing for determination of water content in toluene, including sample preparation, homogeneity and stability test, the results of statistics of iteration robust statistic technique and analysis, summarized and analyzed those of the different test standards which are widely used in the laboratories, put forward the technological suggestions for the improvement of the test quality of water content. Satisfactory results were obtained by 43 laboratories, amounting to 89.6% of the total participating laboratories.

  5. Reactivity of lignin and problems of its oxidative destruction with peroxy reagents

    International Nuclear Information System (INIS)

    Demin, Valerii A; Shereshovets, Valerii V; Monakov, Yurii B

    1999-01-01

    Published data on reactivity and oxidation of lignin and model compounds with hydrogen peroxide, ozone and chlorine dioxide as well as on oxidative destruction of the sulfate pulp lignin with various reagents during bleaching are systematised and generalised. Concepts of lignin activation towards its selective oxidation and kinetic features of sulfate pulp oxidative delignification are considered. The bibliography includes 157 references.

  6. Preparation of para-chloroaniline: a simple, fast and inexpensive experiment

    International Nuclear Information System (INIS)

    Bastos, Renato Saldanha; Cunha, Andrea Sousa da; Silva, Lucyane Costa da; Oliveira, Carina Cantelle Pacheco de; Rezende, Claudia M.; Pinto, Angelo C.

    2008-01-01

    Experiments simple, short and efficient for experimental disciplines in undergraduate courses in Chemistry are an excellent opportunity for students to consolidate the learning of theoretical concepts in classical chemical transformations. The use of a safe reagent, of low cost and easy access is the motivation for this communication, that describes the use of trichloroisocyanuric acid - a chlorinating agent used in the treatment of swimming pool water - for the chlorination of acetanilide, an intermediate in the preparation of para-chloroaniline. (author)

  7. Evaluation of resistance form of different preparation features on mandibular molars

    Directory of Open Access Journals (Sweden)

    Bajoghli Farshad

    2013-01-01

    Full Text Available Aims: Resistance form of full metal-ceramic crown is an important feature that determines longevity of these restorations. This study evaluated the resistance form of full metal-ceramic prepared with four different design features. Materials and Methods: An acrylic tooth was prepared with 20° total occlusal convergence (TOC angle, 2.5 mm of occlusocervical dimension and a shoulder finishing line. This design lacked resistance form. The crown preparation was subsequently modified by preparing Mesial Occlusal Distal isthmus, placing occlusal inclined plane, and reducing TOC. Four metal dies from these designs were constructed by lathe machine and then 10 metal copings were fabricated for each preparation. Metal coping were cemented on metal dies with temp-bond cement. Force was applied at 45° from lingual to buccal direction with universal testing machine. Statistical analysis used: The data were evaluated by Kruskal-Wallis and non-parametric Mann-Whitney test. Results: All features increased resistance form when compare to control group. However, reduce TOC group showed greatest value of resistance. Conclusion: Within the limitation of this study, reducing the tapering of occlusocervival dimension is the most effective way in increasing resistance form, although, other features were also effective.

  8. Mechanical Behaviour of Lined Pipe

    NARCIS (Netherlands)

    Hilberink, A.

    2011-01-01

    Installing lined pipe by means of the reeling installation method seems to be an attractive combination, because it provides the opportunity of eliminating the demanding welds from the critical time offshore and instead preparing them onshore. However, reeling of lined pipe is not yet proven

  9. One-carbon 13C-labeled synthetic intermediates. Comparison and evaluation of preparative methods

    International Nuclear Information System (INIS)

    Ott, D.G.

    1978-01-01

    Frequently the biggest stumbling block to the synthesis of a structurally complex labeled compound is obtaining the required low molecular weight, structurally simple, isotopic intermediates. Selection of a particular scheme from various alternatives depends on the available capabilities and quantity of product desired, as well as on anticipated future requirements and need for related compounds. Many of the newer reagents for organic synthesis can be applied effectively to isotopic preparations with improvements of yields and simplification of procedures compared to established classical methods. New routes developed for higher molecular weight compounds are sometimes not directly adaptable to the one-carbon analogs, either because of isolation difficulties occasioned by physical properties or by chemical reactivities peculiar to their being first members of homologous series. Various routes for preparation of carbon-13 labeled methanol, formaldehyde, and cyanide are compared

  10. Synthesis and studies of Y-Ba-Cu-O high temperature superconductor prepared by sol-gel method

    International Nuclear Information System (INIS)

    Grigoryan, S.G.; Manukyan, A.L.; Hayrapetyan, A.G.; Arzumanyan, A.M.; Rashidyan, L.H.; Mkrtichyan, N.Y.; Mkrtchyan, A.A.; Kurginyan, K.A.; Trozyan, A.H.; Vardanyan, R.S.

    2004-01-01

    The method of preparation of Y-Ba-Cu-O high temperature superconducting materials by sol-gel processing technique both for powders and thin films are described. All these methods are based on using yttrium alkoxides as precursors, which are not ready available reagents, besides the majority of these methods use copper alkoxides, which show low solubility in organic solvents, moreover they are very sensitive to hydrolysis in air. The new method of preparation of Y-Ba-Cu-O ceramic materials by sol-gel processing technique based on new and convenient precursors stable in air, having high compatibility with each other is offered. Basic scientific and technological issues related to the synthesis of bulk materials, their structure and electrical conductivity are discussed

  11. Analogs of N-cynnamoylphenylhydroxylamine as reagents for amperometric determination of scandium

    International Nuclear Information System (INIS)

    Shvedene, N.V.; Gallaj, Z.A.; Sheina, N.M.; Zujkova, N.V.

    1978-01-01

    To decrease the detection limit of scandium and increase selectivity of amperometric determination, oxidation of 2-furylacryloyl-N-p-chlorophenylhydroxylamine (FACPhHA) and 3-styrylacryloyl-N-phenylhydroxylamine (SAPhHA) on a graphite electrode has been studied by volt-amperometry. The possibility has been established of using the oxidation current of the reagent for plotting the titration curves. The solubility of scandium complexes with FACPhHA and SAPhHA under conditions of titration against the background with pH 6.0 has been determined and equals (2.1+-0.3)x10 -6 and (5.3+-0.3)x10 -7 , respectively. The methods have been developed of amperometric determination of scandium with the use of the considered reagents against backgrounds with pH 5.5-6.5. The use of SAPhHA has decreased the limit of scandium detection down to 0.1 mgk/ml. Besides, the amperometric method makes it possible to titrate in turbid and coloured media what is an advantage of this method. The developed method is used for determination of scandium in scandium silicide

  12. [Anti-tumor effects of DDP-PLLA-CNTs on human cholangiocarcinoma cell line in vitro].

    Science.gov (United States)

    Li, Maolan; Lu, Wei; Zhang, Fei; Ding, Qichen; Wu, Xiangsong; Tan, Zhujun; Wu, Wenguang; Weng, Hao; Wang, Xuefeng; Shi, Weibin; Dong, Ping; Gu, Jun; Liu, Yingbin

    2014-11-04

    To explore the antitumor effects of DDP-PLLA-CNTs on human cholangiocarcinoma cell line. DDP-PLLA-CNTs were prepared with the method of ultrasound emulsification. The morphology of DDP-PLLA-CNTs was determined by scanning electron microscope (SEM). And its drug loading and drug release curve in vitro was detected by UV-Vis-NIR spectrophotometer. CCK8 was used to test the cytotoxic effects of DDP-PLLA-CNTs at different concentrations on QBC939 cell proliferation.Flow cytometry was employed to measure the changes of apoptotic rate. With excellent controlled-release characteristic of in vitro drug release, DDP-PLLA-CNTs inhibited the proliferation and significantly increased the apoptotic rate of QBC939 cell line. DDP-PLLA-CNTs have drug sustained-release characteristics and can significantly inhibit the proliferation of QBC939 cell line.

  13. Candidate reagents and procedures for the dissolution of Hanford Site single-shell tank sludges

    International Nuclear Information System (INIS)

    Schulz, W.W.; Kupfer, M.J.

    1991-10-01

    At least some of the waste in the 149 single-shell tanks (SST) at the US Department of Energy (DOE) Hanford Site will be retrieved, treated, and disposed of. Although the importance of devising efficient and cost-effective sludge dissolution procedures has long been recognized, a concerted bench-scale effort to devise and test such procedures with actual solids representative of those in Hanford Site SSTs has not been performed. Reagents that might be used, either individually or serially, to dissolve sludges include HNO 3 , HNO 3 -oxalic acid, and HNO 3 -HF. This report consolidates and updates perspectives and recommendations concerning reagents and procedures for dissolving Hanford Site SST and selected double-shell tank (DST) sludges. The principal objectives of this report are as follows: (1) Compile and review existing experimental data on dissolution of actual Hanford Site SST and DST sludges. (2) Further inform Hanford Site engineers and scientists concerning the utility of combinations of thermally unstable complexants (TUCS) reagents and various reducing agents for dissolving SST and DST sludges. (This latter technology has recently been explored at the Argonne National Laboratory.) (3) Provide guidance in laying out a comprehensive experimental program to develop technology for dissolving all types of Hanford Site SST and DST sludges. 6 refs., 1 fig., 4 tabs

  14. Synthesis and characterization of zwitterionic carbon dioxide fixing reagents

    DEFF Research Database (Denmark)

    Mikkelsen, Mette; Jørgensen, Mikkel; Krebs, Frederik C

    2010-01-01

    with 13CO2 labeling and medium pressure NMR. The experiments showed that two of the three reagents were able to form carbamates and thus bind CO2. In addition we investigated this particular class of molecules for the possible formation of neutrally charged spiro compounds and we show that these did...

  15. Chemical profiling of anti-hepatocellular carcinoma constituents from Caragana tangutica Maxim. by off-line semi-preparative HPLC-NMR.

    Science.gov (United States)

    Yang, Xinzhou; Huang, Mi; Cai, Jinyan; Lv, Dan; Lv, Jingnan; Zheng, Sijian; Ma, Xinhua; Zhao, Ping; Wang, Qiang

    2017-05-01

    An EtOAc fraction from the roots of Caragana tangutica Maxim. (CTEA) displayed promising anti-hepatocellular carcinoma (HCC) activity during screening of a traditional Chinese ethnic herb library against HepG2 and Hep3B cell lines. HPLC-based activity profiling of CTEA by combination of MS-guided large-scale semi-preparative HPLC and NMR methods led to the identification of a new pterocarpan glycoside, (-)-maackiain 3-O-6'-O-methyl malonyl-β-d-glucopyranoside (1), together with three known pterocarpan glycosides, (-)-maackiain 3-O-β-d-glucopyranoside (2), 3-O-6'-O-acrylyl-β-d-galactopyranoside (3), and (-)-maackiain 3-O-6'-O-acetyl-β-d-glucopyranoside (4). Compound 1 was isolated during a drug discovery programme aimed at identifying new anti-HCC leads from a natural product library. Anti-HCC study showed that all four compounds exhibited cytotoxic activity with IC 50 values range of 29.1-53.5 μg/mL against HepG2 and Hep3B cell lines.

  16. Preparation of anastrozole loaded PEG-PLA nanoparticles: evaluation of apoptotic response of breast cancer cell lines.

    Science.gov (United States)

    Alyafee, Yusra A; Alaamery, Manal; Bawazeer, Shahad; Almutairi, Mansour S; Alghamdi, Badr; Alomran, Nawaf; Sheereen, Atia; Daghestani, Maha; Massadeh, Salam

    2018-01-01

    Anastrozole (ANS) is an aromatase inhibitor that is widely used as a treatment for breast cancer in postmenopausal women. Despite the wide use of ANS, it is associated with serious side effects due to uncontrolled delivery. In addition, ANS exhibits low solubility and short plasma half-life. Nanotechnology-based drug delivery has the potential to enhance the efficacy of drugs and overcome undesirable side effects. In this study, we aimed to prepare novel ANS-loaded PLA-PEG-PLA nanoparticles (ANS-NPs) and to compare the apoptotic response of MCF-7 cell line to both ANS and ANS-loaded NPs. ANS-NPs were synthesized using double emulsion method and characterized using different methods. The apoptotic response was evaluated by assessing cell viability, morphology, and studying changes in the expression of MAPK3 , MCL1 , and c-MYC apoptotic genes in MCF-7 cell lines. ANS was successfully encapsulated within PLA-PEG-PLA, forming monodisperse therapeutic NPs with an encapsulation efficiency of 67%, particle size of 186±27.13, and a polydispersity index of 0.26±0.11 with a sustained release profile extended over 144 hours. In addition, results for cell viability and for gene expression represent a similar apoptotic response between the free ANS and ANS-NPs. The synthesized ANS-NPs showed a similar therapeutic effect as the free ANS, which provides a rationale to pursue pre-clinical evaluation of ANS-NPs on animal models.

  17. Functionalization of epoxy esters with alcohols as stoichiometric reagents.

    Science.gov (United States)

    Pavlović, Dona; Modec, Barbara; Dolenc, Darko

    2015-01-01

    Glycidyl esters, frequently employed as reactive groups on polymeric supports, were functionalized with alcohols as stoichiometric reagents, yielding β-alkoxyalcohols. Among the solvents studied, best results were obtained in ethers in the presence of a strong proton acid as a catalyst. Alcohols include simple alkanols, diols, protected polyols, 3-butyn-1-ol 3-hydroxypropanenitrile and cholesterol. This protocol represents a convenient way for introduction of various functionalities onto epoxy-functionalized polymers. Under the reaction conditions, some side reactions take place, mostly due to the reactive ester group and water present in the reaction mixture.

  18. Microwave-Assisted Organic Synthesis Using Benign Reaction Medium and Reagents

    Science.gov (United States)

    Account of chemical reactions expedited by microwave (MW) exposure of neat reactants for the rapid one-pot assembly of heterocyclic compounds from in situ generated reactive intermediates via enamines or using hypervalent iodine reagents will be described that can be adapted for ...

  19. Eco-friendly synthesis for MCM-41 nanoporous materials using the non-reacted reagents in mother liquor.

    Science.gov (United States)

    Ng, Eng-Poh; Goh, Jia-Yi; Ling, Tau Chuan; Mukti, Rino R

    2013-03-04

    Nanoporous materials such as Mobil composite material number 41 (MCM-41) are attractive for applications such as catalysis, adsorption, supports, and carriers. Green synthesis of MCM-41 is particularly appealing because the chemical reagents are useful and valuable. We report on the eco-friendly synthesis of MCM-41 nanoporous materials via multi-cycle approach by re-using the non-reacted reagents in supernatant as mother liquor after separating the solid product. This approach was achieved via minimal requirement of chemical compensation where additional fresh reactants were added into the mother liquor followed by pH adjustment after each cycle of synthesis. The solid product of each successive batch was collected and characterized while the non-reacted reagents in supernatant can be recovered and re-used to produce subsequent cycle of MCM-41. The multi-cycle synthesis is demonstrated up to three times in this research. This approach suggests a low cost and eco-friendly synthesis of nanoporous material since less waste is discarded after the product has been collected, and in addition, product yield can be maintained at the high level.

  20. Alkaline phosphatase-fused repebody as a new format of immuno-reagent for an immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyo-Deok; Lee, Joong-jae [Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701 (Korea, Republic of); Kim, Yu Jung [Industrial Biotechnology and Bioenergy Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon (Korea, Republic of); Hantschel, Oliver [School of Life Sciences, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne (Switzerland); Lee, Seung-Goo [Industrial Biotechnology and Bioenergy Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon (Korea, Republic of); Kim, Hak-Sung, E-mail: hskim76@kaist.ac.kr [Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701 (Korea, Republic of)

    2017-01-15

    Enzyme-linked immunoassays based on an antibody-antigen interaction are widely used in biological and medical sciences. However, the conjugation of an enzyme to antibodies needs an additional chemical process, usually resulting in randomly cross-linked molecules and a loss of the binding affinity and enzyme activity. Herein, we present the development of an alkaline phosphatase-fused repebody as a new format of immuno-reagent for immunoassays. A repebody specifically binding to human TNF-α (hTNF-α) was selected through a phage display, and its binding affinity was increased up to 49 nM using a modular engineering approach. A monomeric alkaline phosphatase (mAP), which was previously isolated from a metagenome library, was genetically fused to the repebody as a signal generator, and the resulting repebody-mAP fusion protein was used for direct and sandwich immunoassays of hTNF-α. We demonstrate the utility and potential of the repebody-mAP fusion protein as an immuno-reagent by showing the sensitivity of 216 pg mL{sup −1} for hTNF-α in a sandwich immunoassay. Furthermore, this repebody-mAP fusion protein enabled the detection of hTNF-α spiked in a serum-supplemented medium with high accuracy and reproducibility. It is thus expected that a mAP-fused repebody can be broadly used as an immuno-reagent in immunoassays. - Highlights: • A human TNF-α (hTNF-α)-specific repebody was selected using a phage display. • A monomeric alkaline phosphatase (mAP) was genetically fused to the repebody. • mAP-fused repebody enabled detection of hTNF-α with high sensitivity and accuracy. • mAP-fused repebody can be widely used as a new immuno-reagent in immunoassays.

  1. Comparação de bulas de duas marcas de tiras reagentes utilizadas no exame químico de urina Comparison of product labelings of two marks of reagent strips for the chemical examination of urine

    Directory of Open Access Journals (Sweden)

    Adriana Scotti da Silva Colombeli

    2006-04-01

    Full Text Available INTRODUÇÃO: O exame de urina proporciona informações sobre patologias renais e do trato urinário, bem como algumas moléstias extra-renais. Usualmente o exame químico de urina é feito com tiras reagentes, objetivando tornar a determinação mais rápida, simples e econômica. OBJETIVOS: Comparar bulas de duas marcas de tiras amplamente utilizadas em laboratórios de urinálise (Roche Combur10 Test® UX e Bayer Multistix® 10 SG. MATERIAL E MÉTODO: Compararam-se as bulas quanto aos princípios utilizados nas determinações de pH, proteínas, glicose, cetonas, hemoglobina, bilirrubina, urobilinogênio, nitrito, densidade e leucócitos, além das informações sobre possíveis interferências. RESULTADOS: Foram verificadas diferenças nos reagentes utilizados para detecção dos parâmetros, como é o caso do urobilinogênio (a tira Multistix usa o reagente de Ehrlich, menos específico e mais propenso a interferências analíticas que o sal de diazônio derivado de metoxibenzeno, utilizado na tira Roche; para nitrito, proteína, glicose, bilirrubina e hemoglobina as diferenças foram mais sutis. DISCUSSÃO: Detectou-se diversidade de informações quanto a possíveis interferentes, o que talvez possa ser justificado parcialmente pelas diferenças nos reagentes. Também foram verificadas diferenças nas informações sobre interferências de um idioma para outro, destacando-se a omissão de algumas delas na bula em português. Observou-se grande disparidade na avaliação da intensidade da reação e sua expressão em cruzes, como, por exemplo, no parâmetro glicose, o que pode levar a erros na interpretação do laudo laboratorial. CONCLUSÃO: As observações registradas reforçam a importância de padronizações no exame parcial de urina.BACKGROUND: The urinalysis provides information about renal and urinary diseases, as well as about some extra renal diseases. The chemical examination of urine is done with reagent strips, which allows

  2. Application of cyclic phosphonamide reagents in the total synthesis of natural products and biologically active molecules

    Directory of Open Access Journals (Sweden)

    Thilo Focken

    2014-08-01

    Full Text Available A review of the synthesis of natural products and bioactive compounds adopting phosphonamide anion technology is presented highlighting the utility of phosphonamide reagents in stereocontrolled bond-forming reactions. Methodologies utilizing phosphonamide anions in asymmetric alkylations, Michael additions, olefinations, and cyclopropanations will be summarized, as well as an overview of the synthesis of the employed phosphonamide reagents.

  3. Polyferric sulphate: preparation, characterisation and application in coagulation experiments.

    Science.gov (United States)

    Zouboulis, A I; Moussas, P A; Vasilakou, F

    2008-07-15

    The process of coagulation is a core environmental protection technology, which is mainly used in the water or wastewater treatment facilities. Research is now focused on the development of inorganic pre-polymerised coagulants. A characteristic example is PFS (polyferric sulphate), a relatively new pre-polymerised inorganic coagulant with high cationic charge. In this paper, the role of major parameters, including temperature, types of chemical reagents, ratio r=[OH]/[Fe], rate of base addition in the preparation stages of PFS were investigated. Furthermore, the prepared PFS was characterised based on typical properties, such as the percentage of the polymerised iron present in the compound, z-potential, pH, etc. Moreover, dynamics of coagulation process were examined by means of the Photometric Dispersion Analyzer (PDA). Finally, the coagulation efficiency of PFS in treating kaolin suspension and biologically pre-treated wastewater was evaluated in comparison with the respective conventional coagulant agent. The results indicate that certain parameters, such as the r value, the rate of base addition and the duration and temperature of the polymerisation stage, significantly affected the properties of the PFS. Additionally, the prepared PFS polymerised coagulants exhibit a significantly better coagulation performance than the respective non-polymerised one, i.e. ferric sulphate.

  4. Total Synthesis of Natural Products Using Hypervalent Iodine Reagents

    Directory of Open Access Journals (Sweden)

    Gaetan eMaertens

    2015-01-01

    Full Text Available We present a review of natural product syntheses accomplished in our laboratory during the last five years. Each synthetic route features a phenol dearomatization promoted by an environmentally benign hypervalent iodine reagent. The dearomatizations demonstrate the aromatic ring umpolung concept, and involve stereoselective remodeling of the inert unsaturations of a phenol into a highly functionalized key intermediate that may contain a quaternary carbon center and a prochiral dienone system. Several new oxidative strategies were employed, including transpositions (1,3-alkyl shift and Prins-pinacol, a polycyclization, an ipso rearrangement, and direct nucleophilic additions at the phenol para position. Several alkaloids, heterocyclic compounds, and a polycyclic core have been achieved, including sceletenone (a serotonin reuptake inhibitor, acetylaspidoalbidine (an antitumor agent, fortucine (antiviral and antitumor, erysotramidine (curare-like effect, platensimycin (an antibiotic, and the main core of a kaurane diterpene (immunosuppressive agent and stimulator of apoptosis. These concise and in some cases enantioselective syntheses effectively demonstrate the importance of hypervalent iodine reagents in the total synthesis of bioactive natural products.

  5. satl based lesson for teaching grignard reagents in synthetic organic

    African Journals Online (AJOL)

    IICBA01

    Traditionally, Grignard reagent has been very vital component of such synthetic ... knowledge, the systemic methodology of teaching and learning is the key point. Chemistry is ... chosen in particular to enlighten the students about effectiveness of systemic approach to .... Lectures through Systemic Approach to Teaching and.

  6. Rapid diagnosis of schistosomiasis in Yemen using a simple questionnaire and urine reagent strips.

    Science.gov (United States)

    Bassiouny, H K; Hasab, A A; El-Nimr, N A; Al-Shibani, L A; Al-Waleedi, A A

    2014-05-01

    Schistosomiasis ranks second to malaria in terms of socioeconomic and public health importance in Yemen. This study assessed the validity of a morbidity questionnaire and urine reagent strips as a rapid tool for screening schoolchildren for urinary schistosomiasis as compared with the presence of eggs in urine as the gold-standard parasitological diagnosis. The study examined urine samples and interviewed 696 children (mean age 12.5 years) attending a primary-preparatory school in south Yemen. Urinary schistosomiasis was confirmed in 126 (18.1%) children. Diagnostic performance was poor for 2 items in the morbidity questionnaire (self-reported history of previous infection and self-reported history of antischistosomal treatment). However, self-reported dysuria, self-reported haematuria in the questionnaire and microhaematuria by reagent strips (alone or with macrohaematuria) revealed good diagnostic performance. The results indicated that reagent strips are a valid method for detection of microhaematuria for identifying individuals and communities infected with Schistosoma haematobium.

  7. Two New 1,1,3,3-Tetramethylguanidinium Halochromates (C5H14N3CrO3X (X: Cl, F: Efficient Reagents for Oxidation of Organic Substrates under Solvent-Free Conditions and Microwave Irradiation

    Directory of Open Access Journals (Sweden)

    Kıvılcım Şendıl

    2016-01-01

    Full Text Available Two new mild oxidizing agents 1,1,3,3-tetramethylguanidinium fluorochromate (TMGFC and 1,1,3,3-tetramethylguanidinium chlorochromate (TMGCC were prepared in high yields by reacting tetramethylguanidine with CrO3 and related acid. These reagents are suitable to oxidize various primary and secondary alcohols and oximes to the corresponding carbonyl compounds under solvent-free conditions and microwave irradiation.

  8. An experimental design approach for optimization of spectrophotometric method for estimation of cefixime trihydrate using ninhydrin as derivatizing reagent in bulk and pharmaceutical formulation

    Directory of Open Access Journals (Sweden)

    Yogita B. Wani

    2017-01-01

    Full Text Available The aim of the present work is to use experimental design to screen and optimize experimental variables for developing a spectrophotometric method for determining cefixime trihydrate content using ninhydrin as a derivatizing reagent. The method is based on the reaction of the amino group of cefixime with ninhydrin in an alkaline medium to form a yellow-colored derivative (λmax 436 nm. A two-level full factorial design was utilized to screen the effect of ninhydrin reagent concentration (X1, volume of ninhydrin reagent (X2, heating temperature (X3 and heating time (X4 on the formation of the cefixime–ninhydrin complex Y (absorbance. One way ANOVA and Pareto ranking analyses have shown that the ninhydrin reagent concentration (X1, volume of ninhydrin reagent (X2 and heating temperature (X3 were statistically significant factors (P < 0.05 affecting the formation of the cefixime–ninhydrin complex Y (absorbance. A Box-Behnken experimental design with response surface methodology was then utilized to evaluate the main, interaction and quadratic effects of these three factors on the selected response. With the help of a response surface plot and contour plot the optimum values of the selected factors were determined and used for further experiments. These values were a ninhydrin reagent concentration (X1 of 0.2% w/v, volume of ninhydrin reagent (X2 of 1 mL and heating temperature (X3 of 80 °C. The proposed method was validated according to the ICH Q2 (R1 method validation guidelines. The results of the present study have clearly shown that an experimental design concept may be effectively applied to the optimization of a spectrophotometric method for estimating the cefixime trihydrate content in bulk and pharmaceutical formulation with the least number of experimental runs possible.

  9. The development of a neutralizing amines based reagent for maintaining the water chemistry for medium and high pressures steam boilers

    Science.gov (United States)

    Butakova, M. V.; Orlov, K. A.; Guseva, O. V.

    2017-11-01

    An overview of the development for neutralizing amine based reagent for water chemistry of steam boilers for medium and high pressures was given. Total values of the neutralization constants and the distribution coefficients of the compositions selected as a main criteria for reagent composition. Experimental results of using this new reagent for water chemistry in HRSG of power plant in oil-production company are discussed.

  10. On the possibility concentrating mill sewage treatment from coordination compounds of heavy non-ferrous metals with flotation reagents

    International Nuclear Information System (INIS)

    Monastyrskaya, V.I.; Borovkov, G.A.; Tsalieva, A.G.

    1996-01-01

    Complexing in the system metal ion (M = Cd, Co, Cu, Ni, Pb, Zn) - ligand (ethylenediamine, pyridine, xanthate, thiourea) and sorption of the complexes formed by materials on the basis of polyacrylonitrile (PAN) sorbents have been studied by the methods of spectrophotometry and voltammetry. It has been ascertained that PAN fiber base filtering materials are efficient sorbents for complexes of heavy nonferrous metals with flotation reagents and can be successfully employed for sewage purification at concentrating mills. 17 refs.; 6 figs.; 4 tabs

  11. Coupling Reagent for UV/vis Absorbing Azobenzene-Based Quantitative Analysis of the Extent of Functional Group Immobilization on Silica.

    Science.gov (United States)

    Choi, Ra-Young; Lee, Chang-Hee; Jun, Chul-Ho

    2018-05-18

    A methallylsilane coupling reagent, containing both a N-hydroxysuccinimidyl(NHS)-ester group and a UV/vis absorbing azobenzene linker undergoes acid-catalyzed immobilization on silica. Analysis of the UV/vis absorption band associated with the azobenzene group in the adduct enables facile quantitative determination of the extent of loading of the NHS groups. Reaction of NHS-groups on the silica surface with amine groups of GOx and rhodamine can be employed to generate enzyme or dye-immobilized silica for quantitative analysis.

  12. [Effects of illumination and seed-soaking reagent on seed germination of Solanum nigrum].

    Science.gov (United States)

    Yang, Chuan-Jie; Wei, Shu-He; Zhou, Qi-Xing; Hu, Ya-Hu; Niu, Rong-Cheng

    2009-05-01

    To explore a rapid seed germination method for hyperaccumulator Solanum nigrum, a germination experiment with different illumination and seed-soaking treatments was conducted in constant temperature box and greenhouse, with filter as burgeon base. Under illumination, the germination rate was about 5 times high of that without illumination (P seed germination of S. nigrum. All test seed-soaking reagents could significantly improve the germination rate of S. nigrum (P seeds treated with H2O2 had the shortest germination time. The germination rate of seeds soaked but without cleaning was 2-3 times as high as that of seeds soaked and cleaned with water.

  13. Dewaterability of five sewage sludges in Guangzhou conditioned with Fenton's reagent/lime and pilot-scale experiments using ultrahigh pressure filtration system.

    Science.gov (United States)

    Liang, Jialin; Huang, Shaosong; Dai, Yongkang; Li, Lei; Sun, Shuiyu

    2015-11-01

    Sludge conditioning with Fenton's reagent and lime is a valid method for sludge dewatering. This study investigated the influence of different organic matter content sludge on sludge dewatering and discussed the main mechanism of sludge conditioning by combined Fenton's reagent and lime. The results indicated that the specific resistance to filterability (SRF) of sludge was reduced efficiently by approximately 90%, when conditioned with Fenton's reagent and lime. Through single factor experiments, the optimal conditioning combinations were found. In addition, the relationship between VSS% and consumption of the reagents was detected. Furthermore, it was also demonstrated that the SRF and filtrate TOC values had a significant correlation with VSS% of sludge (including raw and conditioned). The main mechanism of sludge dewatering was also investigated. Firstly, it revealed that the dewaterability of sludge was closely correlated to extracellular polymeric substances (EPS) and bound water contents. Secondly, the results of scanning electron microscopy (SEM) stated that sludge particles were to be smaller and thinner after conditioning. And this structure could easily form outflow channels for releasing free water. Additionally, with the ultrahigh pressure filtration system, the water content of sludge cake conditioned with Fenton's reagent and lime could be reduced to below 50%. Moreover, the economic assessment shows that Fenton's reagent and lime combined with ultrahigh pressure filtration system can be an economical and viable technology for sewage sludge dewatering. Finally, three types of sludge were classified: (1) Fast to dewater; (2) Moderately fast to dewater; (3) Slow to dewater sludge. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Preparation and characterisation of immobilised humic acid on silicon wafer

    International Nuclear Information System (INIS)

    Szabo, Gy.; Guczi, J.; Telegdi, J.; Pashalidis, I.; Szymczak, W.; Buckau, G.

    2005-01-01

    Full text of publication follows: The chemistry of the interactions of radionuclides with humic acid needs to be understood in details so that humate-mediated migration of radionuclides through the environment can be predicted. To achieve such a data in microscopic scale, several detective techniques, such as atomic force microscopy (AFM), chemical force microscopy (CFM), nuclear microprobe analysis (NMA) and X-ray photoelectron spectroscopy (XPS) can be used to measure intermolecular forces and to visualize the surface morphology. The main aim of this work was to provide humic material with specific properties in order to study with different spectroscopic techniques, the complexation behaviour of surface bound humic acid in microscopic scale. Namely, humic acid has been immobilised on silicon wafers in order to mimic surface bound humic substances in natural aquatic systems. In this communication, we present a simple protocol to immobilize humic acid on silicon wafer surface. A tri-functional silane reagent 3-amino-propyl-tri-methoxy-silane (APTES) was used to modify the surface of silicon wafers and appeared to be able to strongly attached soluble humic acid through their carboxylic groups to solid support. Characterisation of the surfaces, after any preparation steps, was done by ATR-FTIR, AFM and TOF-SIMS. These methods have proved that the humic acid forms a relatively homogeneous layer on the wafers. Immobilisation of humic acid on silicon wafer was further proved by binding isotherm of Am/Nd. (authors)

  15. A New Achiral Linker Reagent for the Incorporation of Multiple Amino Groups Into Oligonucleotides

    DEFF Research Database (Denmark)

    1997-01-01

    The present invention relates to a new functionalized achiral linker reagent for incorporating multiple primary amino groups or reporter groups into oligonucleotides following the phosphoramidite methodology. It is possible to substitute any ribodeoxynucleotide, deoxynucleotide, or nucleotide......-oxyl-2,2,5,5-tetramethylpyrrolidine), TEMPO (N-oxyl-2,2,6,6-tetramethylpiperidine), dinitrophenyl, texas red, tetramethyl rhodamine, 7-nitrobenzo-2-oxa-1-diazole (NBD), or pyrene. The present invention also relates to a solid phase support, e.g. a Controlled Pore Glass (CPG), immobilized linker reagent...

  16. Synthesis and flotation activity of reagent-collectors based on dithiocarbonyl and phosphoryl derivatives of amino alcohols

    Directory of Open Access Journals (Sweden)

    Nazgul Orazbaevna Akimbaeva

    2017-09-01

    Full Text Available Research has been carried out to study the flotation activity of new surface active substances among dithiocarbonyl and phosphoryl derivatives of monoethanolamine and diethanolamine on the gold-bearing sulphide ore of the Bestobinskoye deposit of Kazakhstan. Among the first synthesized compounds, effective collectors for selective enrichment of sulfide polymetallic gold ores were found. Sodium N-octyl-N-2-hydroxyethyldithiocarbamate (AA-41 and sodium O-2-(dimethoxyphosphoryl-2-hydroxyethylaminoethylxanthate (GF-2 were proposed as new flotation reagents. They were tested in the flotation of gold-bearing polymetallic ore as additional collectors and showed good results, contributing to an increase in the percentage of gold extraction in the collective concentrate in comparison with the factory basic regime in which a mixture of butyl xanthate (BX and ditiophosphate butyl ether or butyl airoflot (BAF was used. The results of flotation tests indicate that the collective ability of AA-41 flotation agent as an additional collector is at the level of BX. While the GF-2 flotation agent as a collector in combination with BAF provides a higher gold recovery to the concentrate of 90.8%, which is higher than gold recovery when combined with BX and BAF collectors (87.7%. It should be specially emphasized that the consumption of collectors AA-41 and GF-2 in comparison with the BX consumption in the base mode is much lower, so the AA-41 consumption is 11% lower and the consumption of GF-2 is lower by 33%. Methods for synthesizing the AA-41 flotation reagents and GF-2 flotation agents were developed, and the evidence of their structure was given with the help of physicochemical methods (IRS and NMR 1Н, 13С. The principal technological scheme of the process of obtaining the flotation agent-collector GF-2, which showed the best results in the flotation of gold-bearing polymetallic ore, was developed. In the synthesis of the flotation reagent AA-41, one of the

  17. Measurement of the enzymes lactate dehydrogenase and creatine kinase using reflectance spectroscopy and reagent strips.

    OpenAIRE

    Stevens, J F; Tsang, W; Newall, R G

    1983-01-01

    Two new methods for the assay of total activities of lactate dehydrogenase and creatine kinase are described, in which the enzyme activities are measured from a solid-state reagent strip during a kinetic reaction, the reaction being monitored in the ultra-violet region of the spectrum by reflectance spectroscopy. The performances of these methods are evaluated, and compared to conventional "wet" chemistry methods. The solid-phase reagent methods demonstrated precision and accuracy acceptable ...

  18. Reagent' sets for the concentration of sup(99m)Tc and sup(113m)In

    International Nuclear Information System (INIS)

    Bianco de Salas, G.N.; Arciprete, J.; Mitta, A.E.A.

    1976-10-01

    A simple technique for the concentration of the eluates from 99 Mo/sup(99m)Tc and 113 Sn/sup(113m)In generators is described. The reagents' sets provided by the C.N.E.A. for the labelling of different radiopharmaceuticals can be used by only reducing their volumes proportionally. Both concentration techniques for Tc-99m and In-113m will be supplied to users as reagents' sets. (author) [es

  19. Micellar modified spectrophotometric determination of nitrobenzenes based upon reduction with tin(II), diazotisation and coupling with the Bratton-Marshall reagent.

    Science.gov (United States)

    Escrig-Tena, I; Alvarez Rodríguez, L; Esteve-Romero, J; García-Alvarez-Coque, M C

    1998-09-01

    Nitrobenzenes, such as the antibiotic chloramphenicol, the vasodilator nicardipine, and the herbicides dinitramin, dinobuton, fenitrothion, methylparathion, oxyfluorfen, parathion, pendimethalin, quintozene, and trifluralin, were determined by using a spectrophotometric method in the visible region (540 nm). The method was based on the reduction of the nitrobenzenes to arylamines with tin(II) chloride, diazotisation of the arylamines and coupling of the diazonium ions with the Bratton-Marshall reagent. The two latter reactions were performed in a micellar medium of sodium dodecyl sulphate. The linear calibration range was 2x10(-6) to 7x10(-5) M (r>0.999), with limits of detection in the 10(-7) M level, which is 2-6 fold lower with respect to the corresponding spectrophotometric procedure in non-micellar medium. The procedure was applied to the analysis of the compounds in commercial preparations (pharmaceuticals and herbicide formulations) and in water samples, with good recoveries.

  20. Fuel Line: Defense Energy Support Center. Volume 2

    National Research Council Canada - National Science Library

    2000-01-01

    .... Fuel Line is prepared by desktop publishing applications and designed to provide timely, factual information on policies, plans, operations, and technical developments of the Center and interrelated subject matter...