WorldWideScience

Sample records for reactor laguna verde

  1. Prototype fuel fabrication for nuclear reactors of Laguna Verde

    International Nuclear Information System (INIS)

    Nocetti, C.; Torres, J.; Medrano, A.

    1996-01-01

    Four prototype fuel bundles for the Laguna Verde Nuclear Power Plant have been fabricated. the type of nuclear fuel produced is described and the process used is commented. As an example of the fabrication criteria adopted, the production model to determine the density of the U O 2 pellets for the different batches of ceramic powder is described. the results are evaluated using the statistical indexes C p and C pk . (author)

  2. Estimation of fast neutron fluence in steel specimens type Laguna Verde in TRIGA Mark III reactor

    International Nuclear Information System (INIS)

    Galicia A, J.; Francois L, J. L.; Aguilar H, F.

    2015-09-01

    The main purpose of this work is to obtain the fluence of fast neutrons recorded within four specimens of carbon steel, similar to the material having the vessels of the BWR reactors of the nuclear power plant of Laguna Verde when subjected to neutron flux in a experimental facility of the TRIGA Mark III reactor, calculating an irradiation time to age the material so accelerated. For the calculation of the neutron flux in the specimens was used the Monte Carlo code MCNP5. In an initial stage, three sheets of natural molybdenum and molybdenum trioxide (MoO 3 ) were incorporated into a model developed of the TRIGA reactor operating at 1 M Wth, to calculate the resulting activity by setting a certain time of irradiation. The results obtained were compared with experimentally measured activities in these same materials to validate the calculated neutron flux in the model used. Subsequently, the fast neutron flux received by the steel specimens to incorporate them in the experimental facility E-16 of the reactor core model operating at nominal maximum power in steady-state was calculated, already from these calculations the irradiation time required was obtained for values of the neutron flux in the range of 10 18 n/cm 2 , which is estimated for the case of Laguna Verde after 32 years of effective operation at maximum power. (Author)

  3. Thermal limits validation of gamma thermometer power adaption in CFE Laguna Verde 2 reactor core

    Energy Technology Data Exchange (ETDEWEB)

    Cuevas V, G.; Banfield, J. [GE-Hitachi Nuclear Energy Americas LLC, Global Nuclear Fuel, Americas LLC, 3901 Castle Hayne Road, Wilmingtonm, North Carolina (United States); Avila N, A., E-mail: Gabriel.Cuevas-Vivas@ge.com [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Carretera Cardel-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2016-09-15

    This paper presents the status of GEH work on Gamma Thermometer (GT) validation using the signals of the instruments installed in the Laguna Verde Unit 2 reactor core. The long-standing technical collaboration between Comision Federal de Electricidad (CFE), Global Nuclear Fuel - Americas LLC (GNF) and GE-Hitachi Nuclear Energy Americas LLC (GEH) is moving forward with solid steps to a final implementation of GTs in a nuclear reactor core. Each GT is integrated into a slightly modified Local Power Range Monitor (LPRM) assembly. Six instrumentation strings are equipped with two gamma field detectors for a total of twenty-four bundles whose calculated powers are adapted to the instrumentation readings in addition to their use as calibration instruments for LPRMs. Since November 2007, the six GT instrumentation strings have been operable with almost no degradation by the strong neutron and gamma fluxes in the Laguna Verde Unit 2 reactor core. In this paper, the thermal limits, Critical Power Ratio (CPR) and maximum Linear Heat Generation Rate (LHGR), of bundles directly monitored by either Traverse In-core Probes (TIPs) or GTs are used to establish validation results that confirm the viability of TIP system replacement with automatic fixed in-core probes (AFIPs, GTs, in a Boiling Water Reactor. The new GNF steady-state reactor core simulator AETNA02 is used to obtain power and exposure distribution. Using this code with an updated methodology for GT power adaption, a reduced value of the GT interpolation uncertainty is obtained that is fed into the LHGR calculation. This new method achieves margin recovery for the adapted thermal limits for use in the Economic Simplified Boiling Water Reactor (ESBWR) or any other BWR in the future that employs a GT based AFIP system for local power measurements. (Author)

  4. Thermal limits validation of gamma thermometer power adaption in CFE Laguna Verde 2 reactor core

    International Nuclear Information System (INIS)

    Cuevas V, G.; Banfield, J.; Avila N, A.

    2016-09-01

    This paper presents the status of GEH work on Gamma Thermometer (GT) validation using the signals of the instruments installed in the Laguna Verde Unit 2 reactor core. The long-standing technical collaboration between Comision Federal de Electricidad (CFE), Global Nuclear Fuel - Americas LLC (GNF) and GE-Hitachi Nuclear Energy Americas LLC (GEH) is moving forward with solid steps to a final implementation of GTs in a nuclear reactor core. Each GT is integrated into a slightly modified Local Power Range Monitor (LPRM) assembly. Six instrumentation strings are equipped with two gamma field detectors for a total of twenty-four bundles whose calculated powers are adapted to the instrumentation readings in addition to their use as calibration instruments for LPRMs. Since November 2007, the six GT instrumentation strings have been operable with almost no degradation by the strong neutron and gamma fluxes in the Laguna Verde Unit 2 reactor core. In this paper, the thermal limits, Critical Power Ratio (CPR) and maximum Linear Heat Generation Rate (LHGR), of bundles directly monitored by either Traverse In-core Probes (TIPs) or GTs are used to establish validation results that confirm the viability of TIP system replacement with automatic fixed in-core probes (AFIPs, GTs, in a Boiling Water Reactor. The new GNF steady-state reactor core simulator AETNA02 is used to obtain power and exposure distribution. Using this code with an updated methodology for GT power adaption, a reduced value of the GT interpolation uncertainty is obtained that is fed into the LHGR calculation. This new method achieves margin recovery for the adapted thermal limits for use in the Economic Simplified Boiling Water Reactor (ESBWR) or any other BWR in the future that employs a GT based AFIP system for local power measurements. (Author)

  5. Ageing Management Review of the reactor pressure vessels in Laguna Verde NPP

    International Nuclear Information System (INIS)

    Gris Cruz, Magdalena; Arganis, Carlos R.J.; Medina Almazan, A. Liliana

    2012-01-01

    In the present paper, for both units of Laguna Verde Nuclear Power Plant (LVNPP), the Ageing Management Review of the reactor pressure Vessel was carried out, including the identification of the intended functions, the materials and the environments. The evaluation of the ageing effect/mechanism and the Aging management programs currently implemented were prepared. The most important aging effects/ mechanisms are: loss of fracture toughness due to neutron irradiation embrittlement, fatigue, stress corrosion cracking (SCC), general corrosion and erosion-corrosion. The neutron irradiation embrittlement is managed by the reactor vessel materials surveillance program. The fatigue is a Time Limited Aging Analysis (TLAA), for which is necessary to calculate some fatigue usage factors. SCC is managed by, the In service inspections (ISI) program, but also by the Water Chemistry program, including, currently, On Line Noble Chem. The water chemistry program also manages General Corrosion and erosion-corrosion. The results were compared with the GALL report. (author)

  6. Laguna Verde - A photo story

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1980-04-15

    Safety is one of the main factors in the construction and operation of a modern nuclear power plant. There are many barriers between the fission products produced in the fuel elements of the core, and the environment: the cladding of the fuel pins which are enclosed in the reactor core, the pressure vessel containing the core and which in turn is enclosed in the reactor containment, all this being located in a low-pressure secondary containment or reactor building. Despite these precautions, nuclear safety is still a widely-discussed issue. The important fact remains, however, that there has not been a single radiation-induced fatality or serious injury at any civilian nuclear power plant during 20 years of nuclear power generation. This includes the accident that occurred in March 1979 at the Three Mile Island nuclear plant in the USA. A substantial component contributing to safety in a nuclear power plant is the containment. The following photos of Laguna Verde, Mexico's first nuclear power station being constructed at Alta Lucero in Vera Cruz, give an impression of how strong this concrete and steel containment actually is. Laguna Verde consists of two 600 MWe units and the plant is scheduled for commercial operation in 1982. Construction began in 1974. Both units are boiling-water reactors. The photos show, in general, the construction of the primary containment for the reactors (the dry wells). The dry well contains the reactor itself and has two layers: the leak-tight steel liner and the heavy concrete building. The purpose of the primary containment is to retain steam and gases that might escape in an emergency and to direct these through relief tubes to a water pond for cooling. Surrounding this primary containment will be a reactor building which serves as a secondary low-pressure containment, able to operate at pressures up to 0.2 atmospheres.

  7. Questions to the reactors power upgrade of the Nuclear Power Plant of Laguna Verde

    International Nuclear Information System (INIS)

    Salas M, B.

    2014-08-01

    The two reactors of the Nuclear Power Plant of Laguna Verde (NPP-L V) were subjected to power upgrade labors with the purpose of achieving 20% upgrade on the original power; these labors concluded in August 24, 2010 for the Reactor 1 and in January 16, 2011 for the Reactor 2, however in January of 2014, the NNP-L V has not received by part of the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) the new Operation License to be able to work with the new power, because it does not fulfill all the necessary requirements of safety. In this work is presented and analyzed the information obtained in this respect, with data provided by the Instituto Federal de Acceso a la Informacion Publica y Proteccion de Datos (IFAI) and the Comision Federal de Electricidad (CFE) in Mexico, as well as the opinion of some workers of the NPP-L V. The Governing Board of the CFE announcement that will give special continuation to the behavior on the operation and reliability of the NPP-L V, because the frequency of not announced interruptions was increased 7 times more in the last three years. (Author)

  8. Analysis of the documents about the core envelopment of nuclear reactor at the Laguna Verde U-1 power plant

    International Nuclear Information System (INIS)

    Zamora R, L.; Medina F, A.

    1999-01-01

    The degradation of internal components at BWR type reactors is an important subject to consider in the performance availability of the power plant. The Wuergassen nuclear reactor license was confiscated due to the presence of cracking in the core envelopment. In consequence it is necessary carrying out a detailed study with the purpose to avoid these problems in the future. This report presents a review and analysis of documents and technical information referring to the core envelopment of a BWR/5/6 and the Laguna Verde Unit 1 nuclear reactor in Mexico. In this document are presented design data, documents about fabrication processes, and manufacturing of core envelopment. (Author)

  9. Estimation of fast neutron fluence in steel specimens type Laguna Verde in TRIGA Mark III reactor; Estimacion de la fluencia de neutrones rapidos en probetas de acero tipo Laguna Verde en el reactor Triga Mark III

    Energy Technology Data Exchange (ETDEWEB)

    Galicia A, J.; Francois L, J. L. [UNAM, Facultad de Ingenieria, Departamento de Sistemas Energeticos, Ciudad Universitaria, 04510 Ciudad de Mexico (Mexico); Aguilar H, F., E-mail: blink19871@hotmail.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    The main purpose of this work is to obtain the fluence of fast neutrons recorded within four specimens of carbon steel, similar to the material having the vessels of the BWR reactors of the nuclear power plant of Laguna Verde when subjected to neutron flux in a experimental facility of the TRIGA Mark III reactor, calculating an irradiation time to age the material so accelerated. For the calculation of the neutron flux in the specimens was used the Monte Carlo code MCNP5. In an initial stage, three sheets of natural molybdenum and molybdenum trioxide (MoO{sub 3}) were incorporated into a model developed of the TRIGA reactor operating at 1 M Wth, to calculate the resulting activity by setting a certain time of irradiation. The results obtained were compared with experimentally measured activities in these same materials to validate the calculated neutron flux in the model used. Subsequently, the fast neutron flux received by the steel specimens to incorporate them in the experimental facility E-16 of the reactor core model operating at nominal maximum power in steady-state was calculated, already from these calculations the irradiation time required was obtained for values of the neutron flux in the range of 10{sup 18} n/cm{sup 2}, which is estimated for the case of Laguna Verde after 32 years of effective operation at maximum power. (Author)

  10. First fuel reload in Laguna Verde

    International Nuclear Information System (INIS)

    Bahena B, D.

    1992-01-01

    A report containing the activities carried out during the first reload of nuclear fuel and major maintenance in the Laguna Verde nuclear reactor is presented. The previous and the specific activities are included. These last are related without including the technical considerations, data or the operation details, because these data were documented inside the registrations of the CFE, the ININ and in personal way. (Author)

  11. To report the obtained results in the simulation with the FCS-11 and Presto codes of the two first operation cycles of the Laguna Verde Unit 1 reactor

    International Nuclear Information System (INIS)

    Montes T, J.L.; Moran L, J.M.; Cortes C, C.C.

    1990-08-01

    The objective of this work is to establish a preliminary methodology to carry out analysis of recharges for the reactor of the Laguna Verde U-1, by means of the evaluation of the state of the reactor core in its first two operation cycles using the FCS2 and Presto-B codes. (Author)

  12. Laguna Verde: the nuclear debate in Mexico

    International Nuclear Information System (INIS)

    Weinberg, Bill.

    1987-01-01

    Mexico in planning to start up its first nuclear power station at Laguna Verde in the state of Veracruz (1988). The history of the plant is traced; it should have been finished by 1974. Both the fuel and the technology have been imported from the United States for Laguna Verde. The design, a Mark II Boiling Water Reactor, is controversial and there are doubts as to its safety. Opposition to the plant on safety and environmental grounds has grown. In April 1987 a 'Chernobyl anniversary' demonstration had 10,000 protesters and opponents of the plant are becoming more militant. The main opposition is from environmental and 'Green' groups but also includes intellectuals. However, politically, Mexico would find it embarrassing to cancel the plant and also it wants to be seen as a 'First World' rather than a 'Third World' country. (U.K.)

  13. Out of operation in simultaneous way of the two reactors of nucleoelectric central of Laguna Verde(Mexico)

    International Nuclear Information System (INIS)

    Mar, Bernardo Salas

    2013-01-01

    The two nuclear reactors that Mexico has in the Laguna Verde Nuclear Power Plant, were out of operation simultaneously in September 2012. First it was reported that one of the reactors had problems with the diesel generator, while the other had problems with the nuclear fuel reloading. The day after it was reported a problem related to sediment in the Obra de Toma, place the plant feeds seawater to cool the condenser the depth to which it must operate is 6 meters, with the current level of 1.5 meters, causing a lack of cooling water. Finally it was reported the cause of the suspension of operations, the cracks in jet pumps in both reactors. It is described a brief analysis of these opinions. The reactors are of cooling water of General Electric (BWR-5) and generate 1640 MWe each one

  14. First fuel reload in Laguna Verde; Primera recarga de combustible en Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Bahena B, D

    1992-01-15

    A report containing the activities carried out during the first reload of nuclear fuel and major maintenance in the Laguna Verde nuclear reactor is presented. The previous and the specific activities are included. These last are related without including the technical considerations, data or the operation details, because these data were documented inside the registrations of the CFE, the ININ and in personal way. (Author)

  15. To report the obtained results in the simulation with the FCS-11 and Presto codes of the two first operation cycles of the Laguna Verde Unit 1 reactor; Reportar los resultados obtenidos en la simulacion con los codigos FCS-11 y PRESTO de los dos primeros ciclos de operacion del reactor Laguna Verde Unidad 1

    Energy Technology Data Exchange (ETDEWEB)

    Montes T, J.L.; Moran L, J.M.; Cortes C, C.C

    1990-08-15

    The objective of this work is to establish a preliminary methodology to carry out analysis of recharges for the reactor of the Laguna Verde U-1, by means of the evaluation of the state of the reactor core in its first two operation cycles using the FCS2 and Presto-B codes. (Author)

  16. Report on the Fourth Reactor Refueling. Laguna Verde Nuclear Central. Unit 1. April-May 1995

    International Nuclear Information System (INIS)

    Mendoza L, A.; Flores C, E.; Lopez G, C.P.F.

    1995-01-01

    The fourth refueling of the Unit 1 of Laguna Verde Nuclear Central was executed in the period of April 17 to May 31 of 1995 with the participation of a task group of 358 persons, included technicians and radiation protection officials and auxiliaries.The radiation monitoring and radiological surveillance to the workers was present length ways the refueling process and always attached to the ALARA criteria. The check points for radiation levels were set at: primary container or dry well, reloading floor, decontamination room (level 10.5), turbine building and radioactive waste building. To take advantage of the refueling process, rooms 203 and 213 of the turbine buildings were subject to inspection and maintenance work in valves, heaters and drains of heaters. Management aspects as personnel selection and training, costs, and countable are also presented in this report. Owing to the high cost of man-hour of the members of the ININ staff, its participation in the refueling process was in smaller number than years before. (Author)

  17. Start-up and operation of Laguna Verde-2

    International Nuclear Information System (INIS)

    Torres Ramirez, J.F.

    1996-01-01

    The 665 MWe Laguna Verde-2 nuclear generating unit was accepted into commercial operation on April 10, 1995. The boiling water reactor plant by General Electric (GE) was first synchronized with the grid on November 11, 1994. Laguna Verde-2 is identical with Laguna Verde-1 on the same site. That unit had gone critical for the first time in November 1988 and had first been synchronized with the power grid on April 13, 1989. Commercial operation of Laguna Verde-1 had been started on July 29, 1990. Mexico's only nuclear power plant had been built 70 km north of Veracruz on the east coast and had been scheduled to start operation in 1976. As the Mexican nuclear power program was reduced, the scheduled commissioning dates suffered more and more delays. In the full of 1987, the investigation by the Operational Safety Review Team (Osart) of the International Atomic Energy Agency (IAEA) had indicated that the safety requirements of installations and equpiment were met, and that the whole plant was well prepared for fueling. In mid-1988, the Mexican Government had issued the permit to fuel the Laguna Verde-1 reactor. The contract to build the two units had been awarded in 1972/73. No other nuclear power plants are currently under construction or in the planning phase in Mexico. (orig.) [de

  18. Questions to the reactors power upgrade of the Nuclear Power Plant of Laguna Verde; Cuestionamientos al aumento de potencia de los reactores de la Central Nuclear de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Salas M, B., E-mail: salasmarb@yahoo.com.mx [UNAM, Facultad de Ciencias, Departamento de Fisica, Circuito exterior s/n, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2014-08-15

    The two reactors of the Nuclear Power Plant of Laguna Verde (NPP-L V) were subjected to power upgrade labors with the purpose of achieving 20% upgrade on the original power; these labors concluded in August 24, 2010 for the Reactor 1 and in January 16, 2011 for the Reactor 2, however in January of 2014, the NNP-L V has not received by part of the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) the new Operation License to be able to work with the new power, because it does not fulfill all the necessary requirements of safety. In this work is presented and analyzed the information obtained in this respect, with data provided by the Instituto Federal de Acceso a la Informacion Publica y Proteccion de Datos (IFAI) and the Comision Federal de Electricidad (CFE) in Mexico, as well as the opinion of some workers of the NPP-L V. The Governing Board of the CFE announcement that will give special continuation to the behavior on the operation and reliability of the NPP-L V, because the frequency of not announced interruptions was increased 7 times more in the last three years. (Author)

  19. Technical assistance in relationship with the reloading analysis of the Laguna Verde Unit 2 reactor. Executive abstract

    International Nuclear Information System (INIS)

    Alonso V, G.; Castro B, M.; Gallegos E, R.; Hernandez L, H.; Montes T, J.L.; Ortiz S, J. J.; Perusquia C, R.

    1993-11-01

    The objective of the report was to carry out a comparative analysis of costs of energy generation among the designs GE9B of General Electric, 9X9-IX of SIEMENS and SVEA-96 of ABB ATOM, proposed to be used as recharge fuel in the Unit 2 of the Laguna Verde Nuclear Power station. (Author)

  20. Technical and economic proposal for the extension of the Laguna Verde Nuclear Power plant with an additional nuclear reactor

    International Nuclear Information System (INIS)

    Leal C, C.D.; Francois L, J.L.

    2006-01-01

    The increment of the human activities in the industrial environments and of generation of electric power, through it burns it of fossil fuels, has brought as consequence an increase in the atmospheric concentrations of the calls greenhouse effect gases and, these in turn, serious repercussions about the environment and the quality of the alive beings life. The recent concern for the environment has provoked that industrialized countries and not industrialized carry out international agreements to mitigate the emission from these gases to the atmosphere. Our country, like part of the international community, not is exempt of this problem for what is necessary that programs begin guided toward the preservation of the environment. As for the electric power generation, it is indispensable to diversify the sources of primary energy; first, to knock down the dependence of the hydrocarbons and, second, to reduce the emission of polluting gases to the atmosphere. In this item, the nucleo electric energy not only has proven to be safe and competitive technical and economically, able to generate big quantities of electric power with a high plant factor and a considerable cost, but rather also, it is one of the energy sources that less pollutants it emits to the atmosphere. The main object of this work is to carry out a technical and economic proposal of the extension of the Laguna Verde Nuclear power plant (CNLV) with a new nuclear reactor of type A BWR (Advanced Boiling Water Reactor), evolutionary design of the BWR technology to which belong the two reactors installed at the moment in the plant, with the purpose of increasing the installed capacity of generation of the CNLV and of the Federal Commission of Electricity (CFE) with foundation in the sustainable development and guaranteeing the protection of the environment by means of the exploitation of a clean and sure technology that counts at the moment with around 12,000 year-reactor of operational experience in more of

  1. Multi-disciplinary organization for the completion and start-up of the Laguna Verde-2 power reactor

    International Nuclear Information System (INIS)

    1995-01-01

    The optimization of the human and material resources for the pre-operational tests in the Laguna Verde-2 nuclear plant is described. About three thousand specialist of different groups were involved and each one had its own routines and functions with a complicated communication system among them. The optimization aimed at integrating and coordinating the organizational resources and defining the goals to be reached

  2. Fuel management inside the reactor. Report of generation of the nuclear bank for the fuel of the initial load of the Laguna Verde U-1 reactor with the FMS codes; Administracion de combustible dentro del reactor. Reporte de generacion del banco nuclear para el combustible de la carga inicial del reactor de Laguna Verde U-1 con los codigos del FMS

    Energy Technology Data Exchange (ETDEWEB)

    Alonso V, G. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Torres A, C. [CFE, Veracruz (Mexico)

    1991-06-15

    In this work in a general way the form in that it was generated the database of the initial fuel load of the Laguna Verde Unit 1 reactor is described. The initial load is formed with fuel of the GE6 type. The obtained results during the formation of the database in as much as to the behavior of the different cell parameters regarding the one burnt of the fuel and the variation of vacuums in the coolant channel its are compared very favorably with those reported by the General Electric fuel supplier and reported in the design documents of the same one. (Author)

  3. Radiological analysis by the addition of hydrogen and noble metals in the reactors of the Laguna Verde central

    International Nuclear Information System (INIS)

    Padilla C, I.

    2006-01-01

    and of the radiological behavior when applying them, its allowed to settle down strategies in the Laguna Verde Central to control and to reduce the magnitude of the radiological increment in the primary steam lines in both units during the initial period of application. The radiological effects by the addition of hydrogen and of the noble metals, and its incorporation sequence to the reactor are the one reason of this work. (Author)

  4. Study and characterization of noble metal deposits on similar rusty surfaces to those of the reactor U-1 type BWR of nuclear power station of Laguna Verde

    International Nuclear Information System (INIS)

    Flores S, V. H.

    2011-01-01

    In the present investigation work, were determined the parameters to simulate the conditions of internal oxidation reactor circulation pipes of the nuclear power plant of Laguna Verde in Veracruz. We used 304l stainless steel cylinders with two faces prepared with abrasive paper of No. 600, with the finality to obtain similar surface to the internal circulation piping nuclear reactor. Oxides was formed within an autoclave (Autoclave MEX-02 unit B), which is a device that simulates the working conditions of the nuclear reactor, but without radiation generated by the fission reaction within the reactor. The oxidation conditions were a temperature of 280 C and pressure of 8 MPa, similar conditions to the reactor operating in nuclear power plant of Laguna Verde in Veracruz, Mexico (BWR conditions), with an average conductivity of 4.58 ms / cm and 2352 ppb oxygen to simulate normal water chemistry NWC. Were obtained deposits of noble metal oxides formed on 304l stainless steel samples, in a 250 ml autoclave at a temperature range of 180 to 200 C. The elements that were used to deposit platinum-rhodium (Pt-Rh) with aqueous Na 2 Pt (OH) 6 and Na 3 Rh (NO 2 ) 6 , Silver (Ag) with an aqueous solution of AgNO 3 , zirconium (Zr) with aqueous Zr O (NO 3 ) and ZrO 2 , and zinc (Zn) in aqueous solution of Zn (NO 3 ) 2 under conditions of normal water chemistry. Also there was the oxidation of 304l stainless steel specimens in normal water chemistry with a solution of Zinc (Zn) (NWC + Zn). Oxidation of the specimens in water chemistry with a solution of zinc (Zn + NWC) was prepared in two ways: within the MEX-02 autoclave unit A in a solution of zinc and a flask at constant temperature in zinc solution. The oxides formed and deposits were characterized by scanning electron microscopy, energy dispersive X-ray analysis, elemental field analysis and X-ray diffraction. By other hand was evaluated the electrochemical behavior of the oxides formed on the surface of 304l stainless steel

  5. Design optimization of the Laguna Verde nuclear power station fuel recharge; Optimacion del diseno de recargas de combustible para la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Cortes Campos, Carlos Cristobal [Instituto de Investigaciones Electricas, Cuernavaca (Mexico); Montes Tadeo, Jose Luis [Instituto Nacional de Investigaciones Nucleares (ININ), Salazar (Mexico)

    1991-12-31

    It is described, in general terms, the procedure that is followed to accomplish the optimization of the recharge design, and an example is shown where this procedure was applied for the analysis of the type BWR reactor of Unit No. 1 of the Laguna Verde Nuclear Power Station. [Espanol] Se describe en terminos generales el procedimiento que se sigue para realizar la optimacion del diseno de recargas, y se muestra un ejemplo en el que se utilizo dicho procedimiento para el analisis del reactor tipo BWR de la unidad 1, de la Central Laguna Verde (CLV).

  6. Design optimization of the Laguna Verde nuclear power station fuel recharge; Optimacion del diseno de recargas de combustible para la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Cortes Campos, Carlos Cristobal [Instituto de Investigaciones Electricas, Cuernavaca (Mexico); Montes Tadeo, Jose Luis [Instituto Nacional de Investigaciones Nucleares (ININ), Salazar (Mexico)

    1992-12-31

    It is described, in general terms, the procedure that is followed to accomplish the optimization of the recharge design, and an example is shown where this procedure was applied for the analysis of the type BWR reactor of Unit No. 1 of the Laguna Verde Nuclear Power Station. [Espanol] Se describe en terminos generales el procedimiento que se sigue para realizar la optimacion del diseno de recargas, y se muestra un ejemplo en el que se utilizo dicho procedimiento para el analisis del reactor tipo BWR de la unidad 1, de la Central Laguna Verde (CLV).

  7. Analysis of the documents about the core envelopment of nuclear reactor at the Laguna Verde U-1 power plant; Analisis de documentos de los materiales de la envolvente del nucleo del reactor nuclear de la CLV U-1

    Energy Technology Data Exchange (ETDEWEB)

    Zamora R, L.; Medina F, A. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1999-07-01

    The degradation of internal components at BWR type reactors is an important subject to consider in the performance availability of the power plant. The Wuergassen nuclear reactor license was confiscated due to the presence of cracking in the core envelopment. In consequence it is necessary carrying out a detailed study with the purpose to avoid these problems in the future. This report presents a review and analysis of documents and technical information referring to the core envelopment of a BWR/5/6 and the Laguna Verde Unit 1 nuclear reactor in Mexico. In this document are presented design data, documents about fabrication processes, and manufacturing of core envelopment. (Author)

  8. Ultrasonic meters in the feedwater flow to recover thermal power in the reactor of nuclear power plant of Laguna Verde U1 and U2

    International Nuclear Information System (INIS)

    Tijerina S, F.

    2008-01-01

    The engineers in nuclear power plants BWRs and PWRs based on the development of the ultrasonic technology for the measurement of the mass, volumetric flow, density and temperature in fluids, have applied this technology in two primary targets approved by the NRC: the use for the recovery of thermal power in the reactor and/or to be able to realize an increase of thermal power licensed in a 2% (MUR) by 1OCFR50 Appendix K. The present article mentions the current problem in the measurement of the feedwater flow with Venturi meters, which affects that the thermal balance of reactor BWRs or PWRs this underestimated. One in broad strokes describes the application of the ultrasonic technology for the ultrasonic measurement in the flow of the feedwater system of the reactor and power to recover thermal power of the reactor. One is to the methodology developed in CFE for a calibration of the temperature transmitters of RTD's and the methodology for a calibration of the venturi flow transmitters using ultrasonic measurement. Are show the measurements in the feedwater of reactor of the temperature with RTD's and ultrasonic measurement, as well as the flow with the venturi and the ultrasonic measurement operating the reactor to the 100% of nominal thermal power, before and after the calibration of the temperature transmitters and flow. Finally, is a plan to be able to realize a recovery of thermal power of the reactor, showing as carrying out their estimations. As a result of the application of ultrasonic technology in the feedwater of reactor BWR-5 in Laguna Verde, in the Unit 1 cycle 13 it was recover an equivalent energy to a thermal power of 25 MWt in the reactor and an exit electrical power of 6 M We in the turbogenerator. Also in the Unit 2 cycle 10 it was recover an equivalent energy to a thermal power of 40 MWt in the reactor and an exit electrical power of 16 M We in the turbogenerator. (Author)

  9. Analysis of the micro-structural damages by neutronic irradiation of the steel of reactor vessels of the nuclear power plant of Laguna Verde. Characterization of the design steel; Analisis de los danos micro-estructurales por irradiacion neutronica del acero de la vasija de los reactores de la Central Nuclear de Laguna Verde. Caracterizacion del acero de diseno

    Energy Technology Data Exchange (ETDEWEB)

    Moranchel y Rodriguez, M.; Garcia B, A. [IPN, Escuela Superior de Fisica y Matematicas, Departamento de Fisica, Av. Luis Enrique Erro s/n, Unidad Profesional Adolfo Lopez Mateos, Col. Lindavista, 07738 Mexico D. F. (Mexico); Longoria G, L. C., E-mail: mmoranchel@ipn.m [ININ, Direccion de Investigacion Cientifica, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2010-09-15

    The vessel of a nuclear reactor is one of the safety barriers more important in the design, construction and operation of the reactor. If the vessel results affected to the grade of to have fracture and/or cracks it is very probable the conclusion of their useful life in order to guarantee the nuclear safety and the radiological protection of the exposure occupational personnel, of the public and the environment avoiding the exposition to radioactive sources. The materials of the vessel of a nuclear reactor are exposed continually to the neutronic irradiation that generates the same nuclear reactor. The neutrons that impact to the vessel have the sufficient energy to penetrate certain depth in function of the energy of the incident neutron until reaching the repose or to be absorbed by some nucleus. In the course of their penetration, the neutrons interact with the nuclei, atoms, molecules and with the same crystalline nets of the vessel material producing vacuums, interstitial, precipitate and segregations among other defects that can modify the mechanical properties of the steel. The steel A533-B is the material with which is manufactured the vessel of the nuclear reactors of nuclear power plant of Laguna Verde, is an alloy that, among other components, it contains atoms of Ni that if they are segregated by the neutrons impact this would favor to the cracking of the same vessel. This work is part of an investigation to analyze the micro-structural damages of the reactor vessels of the nuclear power plant of Laguna Verde due to the neutronic irradiation which is exposed in a continuous way. We will show the characterization of the design steel of the vessel, what offers a comprehension about their chemical composition, the superficial topography and the crystalline nets of the steel A533-B. It will also allow analyze the existence of precipitates, segregates, the type of crystalline net and the distances inter-plains of the design steel of the vessel. (Author)

  10. Study and characterization of noble metal deposits on similar rusty surfaces to those of the reactor U-1 type BWR of nuclear power station of Laguna Verde; Estudio y caracterizacion de depositos de metales nobles sobre superficies oxidadas similares a las del reactor de la Central de Laguna Verde (CNLV) U1 del tipo BWR

    Energy Technology Data Exchange (ETDEWEB)

    Flores S, V. H.

    2011-07-01

    In the present investigation work, were determined the parameters to simulate the conditions of internal oxidation reactor circulation pipes of the nuclear power plant of Laguna Verde in Veracruz. We used 304l stainless steel cylinders with two faces prepared with abrasive paper of No. 600, with the finality to obtain similar surface to the internal circulation piping nuclear reactor. Oxides was formed within an autoclave (Autoclave MEX-02 unit B), which is a device that simulates the working conditions of the nuclear reactor, but without radiation generated by the fission reaction within the reactor. The oxidation conditions were a temperature of 280 C and pressure of 8 MPa, similar conditions to the reactor operating in nuclear power plant of Laguna Verde in Veracruz, Mexico (BWR conditions), with an average conductivity of 4.58 ms / cm and 2352 ppb oxygen to simulate normal water chemistry NWC. Were obtained deposits of noble metal oxides formed on 304l stainless steel samples, in a 250 ml autoclave at a temperature range of 180 to 200 C. The elements that were used to deposit platinum-rhodium (Pt-Rh) with aqueous Na{sub 2}Pt (OH){sub 6} and Na{sub 3}Rh (NO{sub 2}){sub 6}, Silver (Ag) with an aqueous solution of AgNO{sub 3}, zirconium (Zr) with aqueous Zr O (NO{sub 3}) and ZrO{sub 2}, and zinc (Zn) in aqueous solution of Zn (NO{sub 3}){sub 2} under conditions of normal water chemistry. Also there was the oxidation of 304l stainless steel specimens in normal water chemistry with a solution of Zinc (Zn) (NWC + Zn). Oxidation of the specimens in water chemistry with a solution of zinc (Zn + NWC) was prepared in two ways: within the MEX-02 autoclave unit A in a solution of zinc and a flask at constant temperature in zinc solution. The oxides formed and deposits were characterized by scanning electron microscopy, energy dispersive X-ray analysis, elemental field analysis and X-ray diffraction. By other hand was evaluated the electrochemical behavior of the oxides

  11. The technology transfer and the Laguna Verde power plants

    International Nuclear Information System (INIS)

    Garza, R.F. de La

    1991-01-01

    The process of technology transfer to the construction of Laguna Verde Nuclear Power Plants, Mexico, is described. The options and the efforts for absorbing the technology of Nuclear Power Plant design and construction by the mexican engineers are emphasized. (author)

  12. DCVD Measurements at the Laguna Verde NPP

    Energy Technology Data Exchange (ETDEWEB)

    Chen, J.D.; Gerwing, A.F. [Channel Systems Inc., Pinawa MA (Canada); Kosierb, R. [Canadian Nuclear Safety Commission, Ottawa, ON (Canada); Vones, J.; Broodryck, A. [International Atomic Energy Agency, Vienna (Austria)

    2006-12-30

    A new digital Cerenkov viewing device (DCVD) with high ultraviolet light sensitivity has been developed. Field measurements on BWR spent fuel at Laguna Verde Nuclear Power Plant Unit 2 resulted in new Cerenkov information on GE9 and GE12 spent fuel assemblies. Off-alignment measurements show: quantitative differences in the degree of light collimation from between the fuel rods; lack of light collimation from water rods; and decreased light collimation from partial length rod positions. Hidden rods could also be detected in off-angle views. The results indicate that it may be possible to detect missing partial-length fuel rods in GE12 fuel assemblies. The new DCVD was able to verify low burnup, long-cooled, natural uranium GE6 fuel assemblies.

  13. DCVD Measurements at the Laguna Verde NPP

    International Nuclear Information System (INIS)

    Chen, J.D.; Gerwing, A.F.; Kosierb, R.; Vones, J.; Broodryck, A.

    2006-01-01

    A new digital Cerenkov viewing device (DCVD) with high ultraviolet light sensitivity has been developed. Field measurements on BWR spent fuel at Laguna Verde Nuclear Power Plant Unit 2 resulted in new Cerenkov information on GE9 and GE12 spent fuel assemblies. Off-alignment measurements show: quantitative differences in the degree of light collimation from between the fuel rods; lack of light collimation from water rods; and decreased light collimation from partial length rod positions. Hidden rods could also be detected in off-angle views. The results indicate that it may be possible to detect missing partial-length fuel rods in GE12 fuel assemblies. The new DCVD was able to verify low burnup, long-cooled, natural uranium GE6 fuel assemblies

  14. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    International Nuclear Information System (INIS)

    Cuevas V, G.; Avila N, A.; Calleros M, G.

    2013-10-01

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  15. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    Energy Technology Data Exchange (ETDEWEB)

    Cuevas V, G. [Global Nuclear Fuel, Americas, 3901 Castle Hayne Road, Wilmington, North Carolina (United States); Avila N, A.; Calleros M, G., E-mail: Gabriel.Cuevas-Vivas@gnf.com [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verda, Carretera Veracruz-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2013-10-15

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  16. Validation of SIMULATE-3K for stability analysis of Laguna Verde nuclear plant

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, Rogelio, E-mail: rogelio.castillo@inin.gob.mx [Instituto Nacional de Investigaciones Nucleares, Carretera México-Toluca s/n, La Marquesa, Ocoyoacac, Estado de México 52750 (Mexico); Alonso, Gustavo, E-mail: gustavo.alonso@inin.gob.mx [Instituto Nacional de Investigaciones Nucleares, Carretera México-Toluca s/n, La Marquesa, Ocoyoacac, Estado de México 52750 (Mexico); Instituto Politecnico Nacional, Unidad Profesional Adolfo Lopez Mateos, Ed. 9, Lindavista, D.F. 07300 (Mexico); Ramírez, J. Ramón, E-mail: ramon.ramirez@inin.gob.mx [Instituto Nacional de Investigaciones Nucleares, Carretera México-Toluca s/n, La Marquesa, Ocoyoacac, Estado de México 52750 (Mexico)

    2013-12-15

    Highlights: • Neutronic/thermal hydraulic event in Laguna Verde is modeled. • A good agreement is obtained between SIMULATE-3K results and data plant for frequency and DR. • Other noise analysis techniques are used for the same purpose with good agreement. • Validation of SIMULATE-3K for stability analysis of Laguna Verde is confirmed - Abstract: Boiling Water Reactors are two phase flow systems which are susceptible to different types of flow instabilities. Among these are the coupled neutronic/thermal-hydraulic instabilities, these may compromise established fuel safety limits. These instabilities are characterized by periodic core-power and hydraulic oscillations. SIMULATE-3K code has been tested for stability analysis for several benchmarks, however to qualify the SIMULATE-3K code for a particular power plant a specific reactor plant analysis must be done. In this paper, the plant model of Laguna Verde Nuclear Power Plant is built and SIMULATE-3K is tested against the 1995 coupled neutronic/thermal-hydraulic instability event of Laguna Verde. Results obtained show the adequacy of this code to specific Laguna Verde power plant stability analysis.

  17. Fuel management inside the reactor. Report of generation of the nuclear bank for the fuel of the initial load of the Laguna Verde U-1 reactor with the FMS codes

    International Nuclear Information System (INIS)

    Alonso V, G.; Torres A, C.

    1991-06-01

    In this work in a general way the form in that it was generated the database of the initial fuel load of the Laguna Verde Unit 1 reactor is described. The initial load is formed with fuel of the GE6 type. The obtained results during the formation of the database in as much as to the behavior of the different cell parameters regarding the one burnt of the fuel and the variation of vacuums in the coolant channel its are compared very favorably with those reported by the General Electric fuel supplier and reported in the design documents of the same one. (Author)

  18. Laguna Verde simulator: A new TRAC-RT based application

    International Nuclear Information System (INIS)

    Munoz Cases, J.J.; Tanarro Onrubia, A.

    2006-01-01

    In a partnership with GSE Systems, TECNATOM is developing a full scope training simulator for Laguna Verde Unit 2 (LV2). The simulator design is based upon the current 'state-of-the art technology' regarding the simulation platform, instructor station, visualization tools, advanced thermalhydraulics and neutronics models, I/O systems and automated model building technology. When completed, LV2 simulator will achieve a remarkable level of modeling fidelity by using TECNATOM's TRAC-RT advanced thermalhydraulic code for the reactor coolant and main steam systems, and NEMO neutronic model for the reactor core calculations. These models have been utilized up to date for the development or upgrading of nine NPP simulators in Spain and abroad, with more than 8000 hours of training sessions, and have developed an excellent reputation for its robustness and high fidelity. (author)

  19. Report on the Fourth Reactor Refueling. Laguna Verde Nuclear Central. Unit 1. April-May 1995; Informe de la Cuarta Recarga de Combustible. Central Laguna Verde. Unidad 1. Abril-Mayo 1995

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza L, A; Flores C, E; Lopez G, C P.F.

    1996-12-31

    The fourth refueling of the Unit 1 of Laguna Verde Nuclear Central was executed in the period of April 17 to May 31 of 1995 with the participation of a task group of 358 persons, included technicians and radiation protection officials and auxiliaries.The radiation monitoring and radiological surveillance to the workers was present length ways the refueling process and always attached to the ALARA criteria. The check points for radiation levels were set at: primary container or dry well, reloading floor, decontamination room (level 10.5), turbine building and radioactive waste building. To take advantage of the refueling process, rooms 203 and 213 of the turbine buildings were subject to inspection and maintenance work in valves, heaters and drains of heaters. Management aspects as personnel selection and training, costs, and countable are also presented in this report. Owing to the high cost of man-hour of the members of the ININ staff, its participation in the refueling process was in smaller number than years before. (Author).

  20. Application of a new methodology on the multicycle analysis for the Laguna Verde NPP en Mexico

    International Nuclear Information System (INIS)

    Cortes C, Carlos C.

    1997-01-01

    This paper describes the improvements done in the physical and economic methodologies on the multicycle analysis for the Boiling Water Reactors of the Laguna Verde NPP in Mexico, based on commercial codes and in-house developed computational tools. With these changes in our methodology, three feasible scenarios are generated for the operation of Laguna Verde Nuclear Power Plant Unit 2 at 12, 18 and 24 months. The physical economic results obtained are showed. Further, the effect of the replacement power is included in the economic evaluation. (author). 11 refs., 3 figs., 7 tabs

  1. Design optimization for fuel reloading in Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Cortes Campos, C.C.; Montes Tadeo, J.L.

    1991-01-01

    Procedure followed to perform the design optimation in fuel reloading is described in general words and also is shown an example in which such procedure was uses for analysis of BWR type reactor in unit 1 of Laguna Verde nuclear power plant (Author)

  2. Laguna Verde after the extended power increase

    International Nuclear Information System (INIS)

    Herrera C, M. N.; Castaneda G, M. A.; Cardenas J, J. B.; Garcia de la C, F. M.

    2012-10-01

    The project of extended power increase that was implemented in both units of the nuclear power plant of Laguna Verde beginning with the stage feasibility evaluation in nuclear side of the facilities, that is to say the affectation of the power increase in the equipment s, systems and components of the nuclear power plant; besides the feasibility evaluation a study cost-benefit for the rehabilitated and modernization of the equipment s, systems and components of Plant Balance was realized. Once considered technical and economically feasible the project began the engineering evaluations required to carry out the licensing of the new operation conditions, as well as beginning to the elaboration of the technical specifications purchase of the equipment s, systems and components of the Plant Balance. While on one hand was carried out the administration of the licensing of the extended power increase for other was carried out the necessary engineering to make the physical changes in the conventional side of the nuclear power plant. Once concluded the constructive stage beginning the final stage of the project, the starting-up tests, operation and performance of the Units under the new operation conditions. This work describes this last stage that contains the technical base, the realized tests and the obtained results. (Author)

  3. Analysis of the stability of events occurred in Laguna Verde

    International Nuclear Information System (INIS)

    Castillo D, R.; Ortiz V, J.; Calleros M, G.

    2005-01-01

    The new fuel designs for operation cycles more long have regions of uncertainty bigger that those of the old fuels, and therefore, they can have oscillations of power when an event is presented that causes that the reactor operates to high power and low flow of coolant. During the start up of the reactor there are continued procedures that avoid that oscillations are presented with that which makes sure the stable behavior of the reactor. However, when the reactor is operating to nominal conditions and they are shot or they are transferred to low speed the recirculation pumps, it cannot make sure that the reactor doesn't present oscillations of power when entering to the restricted operation regions. The methods of stability analysis commonly use signs of neutronic noise that require to be stationary, but after a transitory one where they commonly get lost the recirculation pumps the signs they don't have the required characteristics, for what they are used with certain level of uncertainty by the limited validity of the models. In this work the Prony method is used to determine the reactor stability, starting from signs of transitory and it is compared with autoregressive models. Four events are analyzed happened in the Laguna Verde power plant where the reactor was in the area of high power and low flow of coolant, giving satisfactory results. (Author)

  4. Analysis of the stability of events occurred in Laguna Verde; Analisis de estabilidad de eventos ocurridos en Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Castillo D, R.; Ortiz V, J. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Calleros M, G. [CFE, Central Nucleoelectrica Laguna Verde, Carretera Cardel-Nautla Km. 42.5, Alto Lucero, Veracruz (Mexico)

    2005-07-01

    The new fuel designs for operation cycles more long have regions of uncertainty bigger that those of the old fuels, and therefore, they can have oscillations of power when an event is presented that causes that the reactor operates to high power and low flow of coolant. During the start up of the reactor there are continued procedures that avoid that oscillations are presented with that which makes sure the stable behavior of the reactor. However, when the reactor is operating to nominal conditions and they are shot or they are transferred to low speed the recirculation pumps, it cannot make sure that the reactor doesn't present oscillations of power when entering to the restricted operation regions. The methods of stability analysis commonly use signs of neutronic noise that require to be stationary, but after a transitory one where they commonly get lost the recirculation pumps the signs they don't have the required characteristics, for what they are used with certain level of uncertainty by the limited validity of the models. In this work the Prony method is used to determine the reactor stability, starting from signs of transitory and it is compared with autoregressive models. Four events are analyzed happened in the Laguna Verde power plant where the reactor was in the area of high power and low flow of coolant, giving satisfactory results. (Author)

  5. Developing and modeling of the 'Laguna Verde' BWR CRDA benchmark

    International Nuclear Information System (INIS)

    Solis-Rodarte, J.; Fu, H.; Ivanov, K.N.; Matsui, Y.; Hotta, A.

    2002-01-01

    Reactivity initiated accidents (RIA) and design basis transients are one of the most important aspects related to nuclear power reactor safety. These events are re-evaluated whenever core alterations (modifications) are made as part of the nuclear safety analysis performed to a new design. These modifications usually include, but are not limited to, power upgrades, longer cycles, new fuel assembly and control rod designs, etc. The results obtained are compared with pre-established bounding analysis values to see if the new core design fulfills the requirements of safety constraints imposed on the design. The control rod drop accident (CRDA) is the design basis transient for the reactivity events of BWR technology. The CRDA is a very localized event depending on the control rod insertion position and the fuel assemblies surrounding the control rod falling from the core. A numerical benchmark was developed based on the CRDA RIA design basis accident to further asses the performance of coupled 3D neutron kinetics/thermal-hydraulics codes. The CRDA in a BWR is a mostly neutronic driven event. This benchmark is based on a real operating nuclear power plant - unit 1 of the Laguna Verde (LV1) nuclear power plant (NPP). The definition of the benchmark is presented briefly together with the benchmark specifications. Some of the cross-sections were modified in order to make the maximum control rod worth greater than one dollar. The transient is initiated at steady-state by dropping the control rod with maximum worth at full speed. The 'Laguna Verde' (LV1) BWR CRDA transient benchmark is calculated using two coupled codes: TRAC-BF1/NEM and TRAC-BF1/ENTREE. Neutron kinetics and thermal hydraulics models were developed for both codes. Comparison of the obtained results is presented along with some discussion of the sensitivity of results to some modeling assumptions

  6. Severe Accident Simulation of the Laguna Verde Nuclear Power Plant

    Directory of Open Access Journals (Sweden)

    Gilberto Espinosa-Paredes

    2012-01-01

    Full Text Available The loss-of-coolant accident (LOCA simulation in the boiling water reactor (BWR of Laguna Verde Nuclear Power Plant (LVNPP at 105% of rated power is analyzed in this work. The LVNPP model was developed using RELAP/SCDAPSIM code. The lack of cooling water after the LOCA gets to the LVNPP to melting of the core that exceeds the design basis of the nuclear power plant (NPP sufficiently to cause failure of structures, materials, and systems that are needed to ensure proper cooling of the reactor core by normal means. Faced with a severe accident, the first response is to maintain the reactor core cooling by any means available, but in order to carry out such an attempt is necessary to understand fully the progression of core damage, since such action has effects that may be decisive in accident progression. The simulation considers a LOCA in the recirculation loop of the reactor with and without cooling water injection. During the progression of core damage, we analyze the cooling water injection at different times and the results show that there are significant differences in the level of core damage and hydrogen production, among other variables analyzed such as maximum surface temperature, fission products released, and debris bed height.

  7. Laguna Verde nuclear power plant: an experience to consider in advanced BWR design

    International Nuclear Information System (INIS)

    Fuentes Marquez, L.

    2001-01-01

    Laguna Verde is a BWR 5 containment Mark II. Designed by GE, two external re-circulation loops, each of them having two speed re-circulation pump and a flow control valve to define the drive flow and consequently the total core flow an power control by total core flow. Laguna Verde Design and operational experience has shown some insights to be considering in design for advanced BRW reactors in order to improve the potential of nuclear power plants. NSSS and Balance of plant design, codes used to perform nuclear core design, margins derived from engineering judgment, at the time Laguna Verde designed and constructed had conducted to have a plant with an operational license, generating with a very good performance and availability. Nevertheless, some design characteristics and operational experience have shown that potential improvements or areas of opportunity shall be focused in the advanced BWR design. Computer codes used to design the nuclear core have been evolved relatively fast. The computers are faster and powerful than those used during the design process, also instrumentation and control are becoming part of this amazing technical evolution in the industry. The Laguna Verde experience is the subject to share in this paper. (author)

  8. Transient analysis for Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Ramos Pablos, J.C. et.al.

    1991-01-01

    Relationship between transients analysis and safety of Laguna Verde nuclear power plant is described a general panorama of safety thermal limits of a nuclear station, as well as transients classification and events simulation codes are exposed. Activities of a group of transients analysis of electrical research institute are also mentioned (Author)

  9. Core reactor simulation of the Central Laguna Verde (CLV) reactor in stationary state and an example of the application in the recharge options analysis of cycle 3; Simulacion del nucleo del reactor de la Central Laguna Verde (CLV) en estado estacionario y ejemplo de aplicacion en el analisis de alternativas de recarga del ciclo 3

    Energy Technology Data Exchange (ETDEWEB)

    Ocampo Mansilla, Hector; Francois Lacouture, Juan Luis; Blanco Lara, Jesus; Cortes Campos, Carlos Cristobal; Esquivias Montoya, Jesus; Esquivel Torres, Jose Luis; Martin del Campo Marquez, Cecilia [Instituto de Investigaciones Electricas, Cuernavaca (Mexico); Montes Tadeo, Jose Luis [Instituto Nacional de Investigaciones Nucleares (ININ), Salazar (Mexico); Sanchez Herrera, Luciano; Torres Alvarez, Carlos [Comision Federal de Electricidad (CFE), Mexico, D. F. (Mexico)

    1991-12-31

    The results are presented of a study requested by Comision Federal de Electricidad (CFE) for the analysis of Cycle 3, of Unit No. 1 of the Laguna Verde Nuclear Power Station (CLNV) and determine the burning effect impact, carried out with the starting tests and the operation of Cycles 1 and 2 on base of the cycle extension known as coastdown. The calculations were realized with the Code Package FMS for fuel managing, using the Code PRESTO-B that analyzes the reactor in detailed form in three dimensions an in stationary state. In the study the schemes of fraction of recharge proposed by General Electric (GE) were analyzed with the effect of cycle extension. The initial design value of 100 assemblies for Cycle 3, GE proposes to increase such fraction from 112 to 120 assemblies. This impacts the cost of the second recharge and the purpose of this investigation is to analyze options with higher fuel enrichment in U-235 to minimize the number of assemblies in this recharge. The analyses effected show that the designs proposed by GE do not fulfill the required energy proposed for the cycle, even using in the recharge only fuel with 3.03% of enrichment. It is proposed, likewise, the fuel enrichment up to 3.25% to satisfy the energy demand with a minimum of assemblies. [Espanol] Se presentan los resultados de un estudio solicitado por la Comision Federal de Electricidad (CFE) para analizar el ciclo 3, de la unidad 1 de la Central Laguna Verde (CLV), y determinar el impacto del efecto de quemado llevado a cabo con las pruebas de arranque y por la operacion de los ciclos 1 y 2 con base en la tecnica de alargamiento del ciclo conocida como coastdown1. Los calculos se realizaron con el paquete de codigos FMS para la administracion de combustible, usando el codigo PRESTO-B que analiza el reactor en forma detallada en tres dimensiones y en estado estacionario. Se analizaron en el estudio los esquemas de fraccion de recarga propuesta por la General Electric (GE) con el efecto de

  10. Core reactor simulation of the Central Laguna Verde (CLV) reactor in stationary state and an example of the application in the recharge options analysis of cycle 3; Simulacion del nucleo del reactor de la Central Laguna Verde (CLV) en estado estacionario y ejemplo de aplicacion en el analisis de alternativas de recarga del ciclo 3

    Energy Technology Data Exchange (ETDEWEB)

    Ocampo Mansilla, Hector; Francois Lacouture, Juan Luis; Blanco Lara, Jesus; Cortes Campos, Carlos Cristobal; Esquivias Montoya, Jesus; Esquivel Torres, Jose Luis; Martin del Campo Marquez, Cecilia [Instituto de Investigaciones Electricas, Cuernavaca (Mexico); Montes Tadeo, Jose Luis [Instituto Nacional de Investigaciones Nucleares (ININ), Salazar (Mexico); Sanchez Herrera, Luciano; Torres Alvarez, Carlos [Comision Federal de Electricidad (CFE), Mexico, D. F. (Mexico)

    1992-12-31

    The results are presented of a study requested by Comision Federal de Electricidad (CFE) for the analysis of Cycle 3, of Unit No. 1 of the Laguna Verde Nuclear Power Station (CLNV) and determine the burning effect impact, carried out with the starting tests and the operation of Cycles 1 and 2 on base of the cycle extension known as coastdown. The calculations were realized with the Code Package FMS for fuel managing, using the Code PRESTO-B that analyzes the reactor in detailed form in three dimensions an in stationary state. In the study the schemes of fraction of recharge proposed by General Electric (GE) were analyzed with the effect of cycle extension. The initial design value of 100 assemblies for Cycle 3, GE proposes to increase such fraction from 112 to 120 assemblies. This impacts the cost of the second recharge and the purpose of this investigation is to analyze options with higher fuel enrichment in U-235 to minimize the number of assemblies in this recharge. The analyses effected show that the designs proposed by GE do not fulfill the required energy proposed for the cycle, even using in the recharge only fuel with 3.03% of enrichment. It is proposed, likewise, the fuel enrichment up to 3.25% to satisfy the energy demand with a minimum of assemblies. [Espanol] Se presentan los resultados de un estudio solicitado por la Comision Federal de Electricidad (CFE) para analizar el ciclo 3, de la unidad 1 de la Central Laguna Verde (CLV), y determinar el impacto del efecto de quemado llevado a cabo con las pruebas de arranque y por la operacion de los ciclos 1 y 2 con base en la tecnica de alargamiento del ciclo conocida como coastdown1. Los calculos se realizaron con el paquete de codigos FMS para la administracion de combustible, usando el codigo PRESTO-B que analiza el reactor en forma detallada en tres dimensiones y en estado estacionario. Se analizaron en el estudio los esquemas de fraccion de recarga propuesta por la General Electric (GE) con el efecto de

  11. Proposal for implementation of alternative source term in the nuclear power plant of Laguna Verde; Propuesta de implementacion del termino fuente alternativo en la central nuclear Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Bazan L, A.; Lopez L, M.; Vargas A, A.; Cardenas J, J. B. [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Km. 7.5 Carretera Veracruz-Medellin, Dos Bocas, Veracruz (Mexico)], e-mail: ariadna.bazan@cfe.gob.mx

    2009-10-15

    In 2010 the nuclear power plant of Laguna Verde will implement the extended power upbeat in both units of the plant. Agree with methodology of NEDC-33004P-A, (constant pressure power up rate), and the source term of core, for accidents evaluations, were increased in proportion to the ratio of power level. This means that for the case of a design basis accident of loss of coolant an increase of power of 15% originated an increase of 15% in dose to main control room. Using the method of NEDC-33004P-A to extended power upbeat conditions was determined that the dose value to main control room is very near to regulatory limit established by SRP 6.4. By the above and in order to recover the margin, the nuclear power plant of Laguna Verde will calculate an alternative source term following the criteria established in RG 1.183 (alternative radiological source term for evaluating DBA at nuclear power reactor). This approach also have a more realistic dose value using the criterion of 10-CFR-50.67, in addition is predicted to get the benefit of additional operational flexibilities. This paper present the proposal of implementing the alternative source term in Laguna Verde. (Author)

  12. Ultrasonic meters in the feedwater flow to recover thermal power in the reactor of nuclear power plant of Laguna Verde U1 and U2; Medidores ultrasonicos en el flujo de agua de alimentacion para recuperar potencia termica en el reactor de la Central Nuclear Laguna Verde U1 and U2

    Energy Technology Data Exchange (ETDEWEB)

    Tijerina S, F. [CFE, Central Laguna Verde, Km. 42.5 Carretera Cardel-Nautla, Veracruz (Mexico)]. e-mail: francisco.tijerina@cfe.gob.mx

    2008-07-01

    The engineers in nuclear power plants BWRs and PWRs based on the development of the ultrasonic technology for the measurement of the mass, volumetric flow, density and temperature in fluids, have applied this technology in two primary targets approved by the NRC: the use for the recovery of thermal power in the reactor and/or to be able to realize an increase of thermal power licensed in a 2% (MUR) by 1OCFR50 Appendix K. The present article mentions the current problem in the measurement of the feedwater flow with Venturi meters, which affects that the thermal balance of reactor BWRs or PWRs this underestimated. One in broad strokes describes the application of the ultrasonic technology for the ultrasonic measurement in the flow of the feedwater system of the reactor and power to recover thermal power of the reactor. One is to the methodology developed in CFE for a calibration of the temperature transmitters of RTD's and the methodology for a calibration of the venturi flow transmitters using ultrasonic measurement. Are show the measurements in the feedwater of reactor of the temperature with RTD's and ultrasonic measurement, as well as the flow with the venturi and the ultrasonic measurement operating the reactor to the 100% of nominal thermal power, before and after the calibration of the temperature transmitters and flow. Finally, is a plan to be able to realize a recovery of thermal power of the reactor, showing as carrying out their estimations. As a result of the application of ultrasonic technology in the feedwater of reactor BWR-5 in Laguna Verde, in the Unit 1 cycle 13 it was recover an equivalent energy to a thermal power of 25 MWt in the reactor and an exit electrical power of 6 M We in the turbogenerator. Also in the Unit 2 cycle 10 it was recover an equivalent energy to a thermal power of 40 MWt in the reactor and an exit electrical power of 16 M We in the turbogenerator. (Author)

  13. Analysis of the micro-structural damages by neutronic irradiation of the steel of reactor vessels of the nuclear power plant of Laguna Verde. Characterization of the design steel

    International Nuclear Information System (INIS)

    Moranchel y Rodriguez, M.; Garcia B, A.; Longoria G, L. C.

    2010-09-01

    The vessel of a nuclear reactor is one of the safety barriers more important in the design, construction and operation of the reactor. If the vessel results affected to the grade of to have fracture and/or cracks it is very probable the conclusion of their useful life in order to guarantee the nuclear safety and the radiological protection of the exposure occupational personnel, of the public and the environment avoiding the exposition to radioactive sources. The materials of the vessel of a nuclear reactor are exposed continually to the neutronic irradiation that generates the same nuclear reactor. The neutrons that impact to the vessel have the sufficient energy to penetrate certain depth in function of the energy of the incident neutron until reaching the repose or to be absorbed by some nucleus. In the course of their penetration, the neutrons interact with the nuclei, atoms, molecules and with the same crystalline nets of the vessel material producing vacuums, interstitial, precipitate and segregations among other defects that can modify the mechanical properties of the steel. The steel A533-B is the material with which is manufactured the vessel of the nuclear reactors of nuclear power plant of Laguna Verde, is an alloy that, among other components, it contains atoms of Ni that if they are segregated by the neutrons impact this would favor to the cracking of the same vessel. This work is part of an investigation to analyze the micro-structural damages of the reactor vessels of the nuclear power plant of Laguna Verde due to the neutronic irradiation which is exposed in a continuous way. We will show the characterization of the design steel of the vessel, what offers a comprehension about their chemical composition, the superficial topography and the crystalline nets of the steel A533-B. It will also allow analyze the existence of precipitates, segregates, the type of crystalline net and the distances inter-plains of the design steel of the vessel. (Author)

  14. Safety evaluation of the Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Delgado G, J.L.

    1991-01-01

    The present work describe the licensing process for the first nuclear power plant built in Mexico, it presents the difficulties found during the several years of construction and tests until the phrase a level of safety equivalent to that of the country of origin of the nuclear steam supply system could be applicable to Laguna Verde, at least from the point of view of the mexican regulatory body, and also that this statement could be signed for the inspectors of international organizations. (author)

  15. Proposal for implementation of alternative source term in the nuclear power plant of Laguna Verde

    International Nuclear Information System (INIS)

    Bazan L, A.; Lopez L, M.; Vargas A, A.; Cardenas J, J. B.

    2009-10-01

    In 2010 the nuclear power plant of Laguna Verde will implement the extended power upbeat in both units of the plant. Agree with methodology of NEDC-33004P-A, (constant pressure power up rate), and the source term of core, for accidents evaluations, were increased in proportion to the ratio of power level. This means that for the case of a design basis accident of loss of coolant an increase of power of 15% originated an increase of 15% in dose to main control room. Using the method of NEDC-33004P-A to extended power upbeat conditions was determined that the dose value to main control room is very near to regulatory limit established by SRP 6.4. By the above and in order to recover the margin, the nuclear power plant of Laguna Verde will calculate an alternative source term following the criteria established in RG 1.183 (alternative radiological source term for evaluating DBA at nuclear power reactor). This approach also have a more realistic dose value using the criterion of 10-CFR-50.67, in addition is predicted to get the benefit of additional operational flexibilities. This paper present the proposal of implementing the alternative source term in Laguna Verde. (Author)

  16. Range of the radiation monitor for the rigid vent of primary containment during normal and emergency operation for a BWR-5 in Laguna Verde; Rango del monitor de radiacion para el venteo rigido de la contencion primaria durante operacion normal y emergencia para un reactor BWR-5 en Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Tijerina S, F.; Pozos S, A. M.; Cabrera U, S.; Mata A, J. A.; Sandoval V, S.; Ovando C, R.; Vargas A, A.; Gallardo R, I.; Cruz G, M.; Amador C, C., E-mail: francisco.tijerina@cfe.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Subgerencia de Ingenieria, Km 44.5 Carretera Cardel-Nautla, 91476 Laguna Verde, Alto Lucero, Veracruz (Mexico)

    2014-10-15

    The earthquake followed by a tsunami, happened in March, 2011 in the coasts of oriental Japan, caused damages in the nuclear power plants 1 at 4 of Fukushima Daiichi leading to damage of the fuel in three of the reactors and to the radiation liberation to the exterior. As consequence of those events, the regulations requires that the power plants with Primary Containment type Mark I and II evaluate to have a system of rigid vent with a monitoring equipment of radiation effluents. The present work covers the rigid vent of diameter 12 of the Primary Containment, type Mark-II, of nuclear power plant of Laguna Verde in conditions of severe accident and normal operation, low regime of Extended Power Up rate (EPU - 2317 MWt), using the codes MAAP3B, MICROSHILED 5.05 and the Bardach Black Boxes methodology. As a result the measurement range of the radiation monitor that is required for monitoring the gassy liberation to the atmosphere was determined. The conclusion is that the superior limit of the range of the radiation meter during a Severe Accident is of 8.55 E + 05 R/h (8.55 E + 08 m R/h) and the superior limit in normal operation of 1.412 E-11 at 2.540 E-7 R/h (1.412 E-14 at 2.540 E-10 m R/h). (Author)

  17. Current situation of spent fuel management in the Laguna Verde Nuclear Power Plant, Veracruz, Mexico

    International Nuclear Information System (INIS)

    Moreno, C.V.

    1994-01-01

    The Comision Federal de Electricidad (CFE), owner and operator of the Laguna Verde nuclear power plant (2 x 654 MWe BWR), has twice decided to increase the storage capacity of the spent fuel pools of the reactors. The Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS), the national nuclear regulatory authority, approved the increase by a factor of 2.66 in the storage capacity proposal by CFE in 1989. Each reactor spent fuel pool can now hold 614 t HM. The reracking was done at a cost of about US $13 per kg U, which will add only 0.042 mills per kWh to the fuel cycle cost. (author)

  18. Laguna Verde annulus pressurization loads evaluation

    International Nuclear Information System (INIS)

    Castaneda, M. A.; Cruz, M. A.; Cardenas, J. B.; Vargas, A.; Cruz, H. J.; Mercado, J. J.

    2010-10-01

    Annulus pressurization, jet impingement, pipe whip restraint and jet thrust are phenomena related to postulated pipe ruptures. A postulated pipe rupture at the weld between recirculation, or feedwater piping and a reactor nozzle safe end, will lead to a high flow rate of flashing water/steam mixture into the annulus between the reactor pressure vessel and the biological shield wall. The total effect of the vessel and pipe inventory blowdown from the break being postulated must be accounted for in the evaluation. A recirculation line break will give rise to an angular dependent short term pressure differential around the vessel, followed by a longer term pressure buildup in the annulus. A recirculation line postulated rupture may not produce worst case conditions and reference to time intervals for only the recirculation break should be treated superficially. A postulated rupture of the feedwater piping may produce the extreme case for determining: 1) the shield wall and reactor vessel to pedestal interactions, 2) loading on the reactor vessel internals, or 3) responses for the balance of piping attached to the vessel. Recently it was identified a potential issue regarding the criteria used to determine which cases were evaluated for Annulus Pressurization (A P) loads for new loads plants. The original A P loads methodology in the late 1970 and early 1980 years separated the mass/energy release calculation from the structural response calculation based on the implicit assumption that the maximum overall mass/energy release will result in maximizing the structural response and corresponding stresses on the reactor pressure vessel, internals, and containment structures. This process did not consider the dynamic response in the primary and secondary safety related structures, components and equipment. Consequently, the A P loads used as input for design adequacy evaluations of Nuclear Steam Supply System safety related components for new loads plants might have

  19. Technical assistance in relationship with the reloading analysis of the Laguna Verde Unit 2 reactor. Executive abstract; Asistencia tecnica en relacion con el analisis de recargas de la CNLV U-2

    Energy Technology Data Exchange (ETDEWEB)

    Alonso V, G.; Castro B, M.; Gallegos E, R.; Hernandez L, H.; Montes T, J.L.; Ortiz S, J. J.; Perusquia C, R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1993-11-15

    The objective of the report was to carry out a comparative analysis of costs of energy generation among the designs GE9B of General Electric, 9X9-IX of SIEMENS and SVEA-96 of ABB ATOM, proposed to be used as recharge fuel in the Unit 2 of the Laguna Verde Nuclear Power station. (Author)

  20. Early alert system for oscillations detection applied to the Central of Laguna Verde

    International Nuclear Information System (INIS)

    Calleros M, G.; Zapata Y, M.; Avila N, A.; Herrera H, S. F.

    2011-11-01

    The code Early Alert System developed by Engineering of the Reactor of the nuclear power plant of Laguna Verde is presented, showing its reliability like preventive and corrective instrument to external interferences to the reactor core, due to equipment malfunction associated to the typical systems of a nuclear power plant, as those that control the reactor pressure, those that feed water to the reactor, those that control the valves of the main turbine. With this purpose, real cases of application of the System are shown where the results are compared with the independent evaluations carried out by the supplier, observing compatibility in both results. The benefits of the logarithm are discussed in the nuclear industry as soon as in non nuclear ambits. (Author)

  1. Analysis of the three dimensional core kinetics NESTLE code coupling with the advanced thermo-hydraulic code systems, RELAP5/SCDAPSIM and its application to the Laguna Verde Central reactor

    International Nuclear Information System (INIS)

    Salazar C, J.H.; Nunez C, A.; Chavez M, C.

    2004-01-01

    The objective of the written present is to propose a methodology for the joining of the codes RELAP5/SCDAPSIM and NESTLE. The development of this joining will be carried out inside a doctoral program of Engineering in Energy with nuclear profile of the Ability of Engineering of the UNAM together with the National Commission of Nuclear Security and Safeguards (CNSNS). The general purpose of this type of developments, is to have tools that are implemented by multiple programs or codes such a that systems or models of the three-dimensional kinetics of the core can be simulated and those of the dynamics of the reactor (water heater-hydraulics). In the past, by limitations for the calculation of the complete answer of both systems, the developed models they were carried out for separate, putting a lot of emphasis in one but neglecting the other one. These methodologies, calls of better estimate, will be good to the nuclear industry to evaluate, with more high grades of detail, the designs of the nuclear power plant (for modifications to those already existent or for new concepts in the designs of advanced reactors), besides analysing events (transitory and have an accident), among other applications. The coupled system was applied to design studies and investigation of the Laguna Verde Nuclear power plant (CNLV). (Author)

  2. Start-up and commercial operation of the Laguna Verde power plants, unit 1

    International Nuclear Information System (INIS)

    Torres R, J.F.

    1991-01-01

    The main features of the unit 1 of the Laguna Verde Power Plant is presented as well as the phases of the start-up process. The process includes various steps and tests up to start the commercial operation. (author)

  3. Radiological protection in Laguna Verde, the challenge of being better

    International Nuclear Information System (INIS)

    Serrano R, H.

    2008-01-01

    The operation of the nuclear power plants in the last decade is based on the application of standard directed towards the excellence. The nuclear power plant of Laguna Verde (CNLV), is not the exception and in the 18 years of commercial operation, the safety culture has matured in the personnel. Standard and political implemented like in the control of dosimeter alarms, equipment condition, meetings pre-work, the practice of protection to the systems and the fuel, as well as the order and the cleaning have distinguished to the CNLV with other power stations. The sense of property of the personnel towards its work is fundamental for the achievement of results. It is reason for the present work to show since it has been gotten to obtain results directed to the excellence in the activities or of normal operation and recharge, where the security is the principle priority. (Author)

  4. Electrical Systems at Laguna Verde Nuclear Power Plant (LVNPP) after the Fukushima accident

    International Nuclear Information System (INIS)

    Lopez Jimenez, Jose Francisco

    2015-01-01

    the accident in Fukushima Daiichi, for this reason the main electrical equipment belonging to the offsite power system was changed and the electrical analysis was reviewed (such as: short-circuit, load flow, electrical stability analysis, etc.), 2) Generic Letter 2006-02 'Grid Reliability and the Impact on Plant Risk and the Operability of Offsite Power' is in process of implementation, this aims to verify that it maintains compliance with regulatory requirements which govern electrical systems and 3) the USNRC is in the process of reviewing the 10 CFR 50.63 and Regulatory Guide 1.155 'Station Blackout', once issued, CNSNS will require its implementation at Laguna Verde NPP. Based on the above, CNSNS concludes that all actions are being taken to enhance the robustness of Laguna Verde NPP's electrical systems, in order to increase their reliability, safety and operation as required in order to cope with events beyond design basis as that occurred at Fukushima Daiichi and avoid as far as possible damage to the reactor core. (authors)

  5. Validation of the thermal balance of Laguna Verde turbine under conditions of extended power increase

    International Nuclear Information System (INIS)

    Castaneda G, M. A.; Cruz B, H. J.; Mercado V, J. J.; Cardenas J, J. B.; Garcia de la C, F. M.

    2012-10-01

    The present work is a continuation of the task: Modeling of the vapor cycle of Laguna Verde with the PEPSE code to conditions of thermal power licensed at present (2027 MWt) in which the modeling of the vapor cycle of the nuclear power plant of Laguna Verde was realized with PEPSE code (Performance Evaluation of Power System Efficiencies). Once reached the conditions of nominal operation of extended power increase, operating both units to 2371 MWt; after the tests phase of starting-up and operation is necessary to carry out a verification of the proposed design of the vapor cycle for the new operation conditions. All this, having in consideration that the vapor cycle designer only knows the detail of the prospective performance of the main turbine, for all the other components (for example pumps, heat inter changers, valves, reactor, humidity separators and re-heaters, condensers, etc.) makes generic suppositions based on engineering judgment. This way carries out the calculations of thermal balance to determine the guaranteed gross power. The purpose of the present work is to comment the detail of the validation carried out of the specific thermal balance (thermal kit) of the nuclear power plant, making use of the design characteristics of the different components that conform the vapor cycle. (Author)

  6. A radiation monitoring system model for the Laguna Verde nuclear power training simulator

    International Nuclear Information System (INIS)

    Ocampo, M.H.; DeAlbornoz, B.A.

    1988-01-01

    A model for the Radiation Monitoring System of the Laguna Verde Boiling Water Reactor training simulator is presented. This model comprises enough definitions to assure interactions with the processes related, directly or indirectly, with the transport of radioisotopes. It is capable of following a dynamic behavior of the plant so an operator could be trained to become aware of nuclear radiation hazards. The model is composed of three parts: the electronics for the Process and Area Radiation Monitoring System; a lumped parameter transport model for the most representative radioisotopes; and the interactions with the modeled processes as well as with process not being simulated. The first part represents the radiation monitor controls in the vertical board panels of the nuclear station. The second part allows the carrying of nuclear isotopes between processes. The third part defines the way that the process interacts with the electronics at the point of release to environment or the point of detection. Each part of the model has been tested individually, and the transport model has been incorporated as a part of each process required to simulate nuclear radiation. The model parameters has been calculated using typical BWR nuclear radiation data, and Laguna Verde heat balance data at 100% design power. However, tunning will be necessary once the Simulator is integrated and tested. The tunning allows each detecting channel to behave as expected

  7. Components production and assemble of the irradiation capsule of the Surveillance Program of Materials of the nuclear power plant of Laguna Verde

    International Nuclear Information System (INIS)

    Medrano, A.

    2009-01-01

    To predict the effects of the neutrons radiation and the thermal environment about the mechanical properties of the reactor vessel materials of the nuclear power plant of Laguna Verde, a surveillance program is implemented according to the outlines settled by Astm E185-02 -Standard practice for design of surveillance programs for light-water moderated nuclear power reactor vessels-. This program includes the installation of three irradiation capsules of similar materials to those of the reactor vessels, these samples are test tubes for mechanical practices of impact and tension. In the National Institute of Nuclear Research and due to the infrastructure as well as of the actual human resources of the Pilot Plant of Nuclear Fuel Assembles Production it was possible to realize the materials rebuilding extracted in 2005 of Unit 2 of nuclear power plant of Laguna Verde as well as the production, assemble and reassignment of the irradiation capsule made in 2006. At the present time the surveillance materials extracted in 2008 of Unit 1 of the nuclear power plant of Laguna Verde are reconstituting and the components are manufactured for the assembles of the irradiation capsule that will be reinstalled in the reactor vessel in 2010. The purpose of the present work is to describe the necessary components as well as its disposition during the assembles of the irradiation capsule for the surveillance program of the reactors vessel of the nuclear power plant of Laguna Verde. (Author)

  8. Modernization of the turbo in the Laguna Verde Nuclear Power Plant; Modernizacion del turbogrupo en la Central Nuclear de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Liebana, B.; Merino, A.; Cobos, A.; Gonzalez, J. J.

    2010-07-01

    The power increase of the Laguna Verde Nuclear Power Plant is a project for the rehabilitation and modernization of the turbo and associated equipment to get an increase of its power and of its service life. The project scope includes the design, the engineering, the equipment supply, the installation, the testing and the commissioning. This paper describes the first phase of the project.

  9. Reproduction of the flow-power map of the Laguna Verde power plant; Reproduccion del mapa flujo-potencia de la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Amador G, R; Gonzalez M, V M [Comision Nacional de Seguridad Nuclear y Salvaguardias, 03000 Mexico D.F. (Mexico)

    1993-07-01

    The National Commission of Nuclear Safety and Safeguards (CNSNS) requires to have calculation tools which allows it to make analysis independent of the behavior of the reactor core of Laguna Verde nuclear power plant (CNLV) with the purpose to support the evaluation and discharge activities of the fuel recharges licensing. The software package Fms (Fuel Management System) allows to carry out an analysis of the core of the BWR type reactors along the operation cycle to detect possible anomalies and/or helping in the fuel management. In this work it is reproduced the flow-power for the CNLV using the Presto code of the Fms software package. The comparison of results with the map used by the operators of CNLV shows good agreement between them. Another exercise carried out was the changes study that the axial and radial power outlines undergo as well as the thermohydraulic parameters (LHGR, APLHGR, CPR) when moving a control rod. The obtained results show that is had the experience to effect analysis of the reactor behavior using the Presto-Fms code therefore the study of the rest of the software package for the obtention of nuclear parameters used in this code is recommended. (Author)

  10. Analysis of internal events for the Unit 1 of the Laguna Verde nuclear power station

    International Nuclear Information System (INIS)

    Huerta B, A.; Aguilar T, O.; Nunez C, A.; Lopez M, R.

    1993-01-01

    This volume presents the results of the starter event analysis and the event tree analysis for the Unit 1 of the Laguna Verde nuclear power station. The starter event analysis includes the identification of all those internal events which cause a disturbance to the normal operation of the power station and require mitigation. Those called external events stay beyond the reach of this study. For the analysis of the Laguna Verde power station eight transient categories were identified, three categories of loss of coolant accidents (LOCA) inside the container, a LOCA out of the primary container, as well as the vessel break. The event trees analysis involves the development of the possible accident sequences for each category of starter events. Events trees by systems for the different types of LOCA and for all the transients were constructed. It was constructed the event tree for the total loss of alternating current, which represents an extension of the event tree for the loss of external power transient. Also the event tree by systems for the anticipated transients without scram was developed (ATWS). The events trees for the accident sequences includes the sequences evaluation with vulnerable nucleus, that is to say those sequences in which it is had an adequate cooling of nucleus but the remoting systems of residual heat had failed. In order to model adequately the previous, headings were added to the event tree for developing the sequences until the point where be solved the nucleus state. This process includes: the determination of the failure pressure of the primary container, the evaluation of the environment generated in the reactor building as result of the container failure or cracked of itself, the determination of the localization of the components in the reactor building and the construction of boolean expressions to estimate the failure of the subordinated components to an severe environment. (Author)

  11. Actinides inventory of the nuclear power plant of Laguna Verde Unit 1; Inventario de actinidos de la Central Nuclear Laguna Verde Unidad 1

    Energy Technology Data Exchange (ETDEWEB)

    Martinez C, E.; Ramirez S, J. R. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Alonso V, G., E-mail: eduardo.martinez@inin.gob.mx [IPN, Escuela Superior de Fisica y Matematicas, Av. Instituto Politecnico Nacional s/n, U. P. Adolfo Lopez Mateos, Col. San Pedro Zacatenco, 07738 Mexico D. F. (Mexico)

    2013-10-15

    At the present time 435 nuclear power reactors exist for the electricity generation operating in the world and 63 in construction. Mexico has two reactors type BWR in the nuclear power plant of Laguna Verde. The nuclear fuel that is used in the nuclear reactors is retired of the reactor core when the energy that this contained has been extracted. This used fuel is known as spent nuclear fuel, the problem with this fuel is that was irradiated inside the reactor and continuous emitting a high radiation, as well as a significant heat quantity when being extracted, for what is necessary to maintain it in cooling and with some shielding to be protected of the radiation that emits. This objective is achieved confining the fuel in the spent nuclear fuel pool, where it is cooled and the same pool provides the necessary shielding to maintain the surroundings in safety radiation levels for the personnel that work in the power plant. An inconvenience of the pools is its limited storage capacity and that after certain time is necessary to remove the fuel, according to the established regulation to continue operating. To correct this inconvenience, two alternatives of spent fuel disposition exist, 1) the final disposition in deep geologic repositories and 2) the reprocessing and recycled of spent fuel. Each alternative presents its particularities and specific problems; however taking many years to be able to implement anyone of them. To carry out the second option, is indispensable to estimate the total mass of actinides generated in the spent nuclear fuel, that which represents to develop a methodology for it, this action is the main purpose of the present work. Inside our calculation method was necessary to appeal to diverse computation tools as the codes Origin-S and Keno V.a. Later on the obtained were compared with a problem type Benchmark, being obtained a smaller absolute error to 1.0%. (Author)

  12. Training in fundamentals of radiological coverage in Laguna Verde NPP

    International Nuclear Information System (INIS)

    Lara H, M. A.

    2014-10-01

    In 2010, the Institute of Nuclear Power Operations (INPO) celebrates the Knowledge Transfer and Retention Workshop, an event where nuclear regulators and operators presented the strategies that various NPP to worldwide were implemented to mitigate the consequences of this generational change and take advantage of it, the trend in the presented works was the same: the generational change occurs in a faster way that the transfer of knowledge, the future was already here and many NPP had not been adequately prepared to train its nuclear technicians and engineers in the tasks demanded by the industry of them, so in addition to preparing these workers to forced marches was necessary to establish strategies to retain at more experienced staff in the industry. The Laguna Verde NPP has not been exempt to this process; the preparation of personnel squares to replace those that reaching retirement age in the Comision Federal de Electricidad (CFE) has become extensive in the last five years, sometimes leading to have personnel covering functions without an alternate to the next lower position, the cause? Not enough staff. In the specific case of radiation protection (Rp) the time required for obtaining the status of Rp technician according to the ANSI/ANS 3.1 standard is 2 years, one of the tasks that most occupies part of these two years is training in radiological coverage, this training requires a mix of knowledge and experience, recently one of the concepts used for training in Rp is the evaluation and management of the radiological risk, topic that is considered in this technical work. (Author)

  13. Considerations for increasing unit 1 spent fuel pool capacity at the Laguna Verde station

    International Nuclear Information System (INIS)

    Vera, A.

    1992-01-01

    To increase the spent fuel storage capacity at the Laguna Verde Station in a safe and economical manner and assure a continuous operation of the first Mexican Nuclear Plant, Comision Federal de Electricidad (CFE), the Nation's Utility, seeked alternatives considering the overall world situation, the safety and licensing aspects, as well as the economics and the extent of the nuclear program of Mexico. This paper describes the alternatives considered, their evaluation and how the decision taken by CFE in this field, provides the Laguna Verde Station with a maximum of 37 years storage capacity plus full core reserve

  14. Analysis of the Power oscillations event in Laguna Verde Nuclear Power Plant. Preliminary Report

    International Nuclear Information System (INIS)

    Gonzalez M, V.M.; Amador G, R.; Castillo, R.; Hernandez, J.L.

    1995-01-01

    The event occurred at Unit 1 of Laguna Verde Nuclear Power Plant in January 24, 1995, is analyzed using the Ramona 3 B code. During this event, Unit 1 suffered power oscillation when operating previous to the transfer at high speed recirculating pumps. This phenomenon was timely detected by reactor operator who put the reactor in shut-down doing a manual Scram. Oscillations reached a maximum extent of 10.5% of nominal power from peak to peak with a frequency of 0.5 Hz. Preliminary evaluations show that the event did not endangered the fuel integrity. The results of simulating the reactor core with Ramona 3 B code show that this code is capable to moderate reactor oscillations. Nevertheless it will be necessary to perform a more detailed simulation of the event in order to prove that the code can predict the beginning of oscillations. It will be need an additional analysis which permit the identification of factors that influence the reactor stability in order to express recommendations and in this way avoid the recurrence of this kind of events. (Author)

  15. National autonomous university of Mexico RELAP/SCDAPSIM-based plant simulation and training applications to the Laguna Verde NPP

    International Nuclear Information System (INIS)

    Chavez-Mercado, C.; Hohorst, J.K.; Allison, C.M.

    2004-01-01

    The RELAP/SCDAPSIM code, designed to predict the behavior of reactor systems during normal and accident conditions, is being developed by Innovative Systems Software as part of the International SCDAP Development and Training Program (SDTP). This code is being used as the simulator engine for the National Autonomous University of Mexico's Simulation and Training Facility located at the Campus Morelos in Jiutepec, Mexico. This paper describes the RELAP/SCDAPSIM code, the Simulation and Training facility at the National Autonomous University of Mexico, and the application of the training system to the Laguna Verde Nuclear Power Plant located in the Mexican state of Veracruz. (author)

  16. Introduction of fuel GE14 in the nuclear power plant of Laguna Verde for the extended increase of power; Introduccion del combustible GE14 en la central nuclear Laguna Verde para el aumento de potencia extendido

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez M, N.; Vargas A, A. F.; Cardenas J, J. B.; Contreras C, P. [CFE, Central Nuclear Laguna Verde, Subgerencia de Ingenieria, Carretera Veracruz-Medellin Km. 7.5 (Mexico)]. e-mail: natividad.hernandez@cfe.gob.mx

    2008-07-01

    The project of extended increase of power responds to a necessity of electrical energy in the country, increasing the thermal exit of the reactors of the nuclear power plant of Laguna Verde of 2027 MWt to 2317 MWt. In order to support this transition, changes will make in the configuration of the reactor core and in the operation strategies of the cycle, also they will take initiatives to optimize the economy in fuel cycle. At present in both reactors of the nuclear plant of Laguna Verde fuel GE12 is used. The fuel GE14 presents displays with respect to the GE12, some improvements in the mechanical design and consequently in its performance generally. Between these improvements we can mention: 1. Spacers of high performance. 2. Shielding with barrier. 3. Filter for sweepings {sup d}ebris{sup a}nd 4. Fuel rods of minor partial length. The management of nuclear power plants has decided to introduce the use of fuel GE14 in Laguna Verde in the reload 14 for Unit 1 and of the reload 10 for Unit 2. The process of new introduction fuel GE14 consists of two stages, first consists on subjecting the one new design of fuel to the regulator organism in the USA: Nuclear Regulatory Commission, in Mexico the design must be analyzed and authorized by the National Commission of Nuclear Safety and Safeguards, for its approval of generic form, by means of the demonstration of the fulfillment with the amendment 22 of GESTAR II, the second stage includes the specific analyses of plant to justify the use of the new fuel design in a reload core. The nuclear plant of Laguna Verde would use some of the results of the security analyses that have been realized for the project of extended increase of power with fuel GE14, to document the specific analyses of plant with the new fuel design. The result of the analyses indicates that the reload lots are increased of 116-120 assemblies in present conditions (2027 MWt) to 140-148 assemblies in conditions of extended increase of power (2317 MWt

  17. New aspects in the radiological emergency plan outside the Nuclear power plant of Laguna Verde

    International Nuclear Information System (INIS)

    Alva L, S.

    1991-01-01

    The Mexican government through the National Commission of Nuclear Safety and Safeguards has imposed to the Federal Commission of Electricity to fulfill the requirement of having a functional Emergency Plan and under the limits that the regulator organisms in the world have proposed. The PERE (Plan of External Radiological Emergency) it has been created for the Nuclear Power station of Laguna Verde, Mexico

  18. Internal event analysis of Laguna Verde Unit 1 Nuclear Power Plant. System Analysis

    International Nuclear Information System (INIS)

    Huerta B, A.; Aguilar T, O.; Nunez C, A.; Lopez M, R.

    1993-01-01

    The Level 1 results of Laguna Verde Nuclear Power Plant PRA are presented in the I nternal Event Analysis of Laguna Verde Unit 1 Nuclear Power Plant , CNSNS-TR-004, in five volumes. The reports are organized as follows: CNSNS-TR-004 Volume 1: Introduction and Methodology. CNSNS-TR-004 Volume 2: Initiating Event and Accident Sequences. CNSNS-TR-004 Volume 3: System Analysis. CNSNS-TR-004 Volume 4: Accident Sequence Quantification and Results. CNSNS-TR-004 Volume 5: Appendices A, B and C. This volume presents the results of the system analysis for the Laguna Verde Unit 1 Nuclear Power Plant. The system analysis involved the development of logical models for all the systems included in the accident sequence event tree headings, and for all the support systems required to operate the front line systems. For the Internal Event analysis for Laguna Verde, 16 front line systems and 5 support systems were included. Detailed fault trees were developed for most of the important systems. Simplified fault trees focusing on major faults were constructed for those systems that can be adequately represent,ed using this kind of modeling. For those systems where fault tree models were not constructed, actual data were used to represent the dominant failures of the systems. The main failures included in the fault trees are hardware failures, test and maintenance unavailabilities, common cause failures, and human errors. The SETS and TEMAC codes were used to perform the qualitative and quantitative fault tree analyses. (Author)

  19. Modernization of the turbo in the Laguna Verde Nuclear Power Plant

    International Nuclear Information System (INIS)

    Liebana, B.; Merino, A.; Cobos, A.; Gonzalez, J. J.

    2010-01-01

    The power increase of the Laguna Verde Nuclear Power Plant is a project for the rehabilitation and modernization of the turbo and associated equipment to get an increase of its power and of its service life. The project scope includes the design, the engineering, the equipment supply, the installation, the testing and the commissioning. This paper describes the first phase of the project.

  20. Introduction of fuel GE14 in the nuclear power plant of Laguna Verde for the extended increase of power

    International Nuclear Information System (INIS)

    Hernandez M, N.; Vargas A, A. F.; Cardenas J, J. B.; Contreras C, P.

    2008-01-01

    The project of extended increase of power responds to a necessity of electrical energy in the country, increasing the thermal exit of the reactors of the nuclear power plant of Laguna Verde of 2027 MWt to 2317 MWt. In order to support this transition, changes will make in the configuration of the reactor core and in the operation strategies of the cycle, also they will take initiatives to optimize the economy in fuel cycle. At present in both reactors of the nuclear plant of Laguna Verde fuel GE12 is used. The fuel GE14 presents displays with respect to the GE12, some improvements in the mechanical design and consequently in its performance generally. Between these improvements we can mention: 1. Spacers of high performance. 2. Shielding with barrier. 3. Filter for sweepings d ebris a nd 4. Fuel rods of minor partial length. The management of nuclear power plants has decided to introduce the use of fuel GE14 in Laguna Verde in the reload 14 for Unit 1 and of the reload 10 for Unit 2. The process of new introduction fuel GE14 consists of two stages, first consists on subjecting the one new design of fuel to the regulator organism in the USA: Nuclear Regulatory Commission, in Mexico the design must be analyzed and authorized by the National Commission of Nuclear Safety and Safeguards, for its approval of generic form, by means of the demonstration of the fulfillment with the amendment 22 of GESTAR II, the second stage includes the specific analyses of plant to justify the use of the new fuel design in a reload core. The nuclear plant of Laguna Verde would use some of the results of the security analyses that have been realized for the project of extended increase of power with fuel GE14, to document the specific analyses of plant with the new fuel design. The result of the analyses indicates that the reload lots are increased of 116-120 assemblies in present conditions (2027 MWt) to 140-148 assemblies in conditions of extended increase of power (2317 MWt). (Author)

  1. Reproduction of the flow-power map of the Laguna Verde power plant

    International Nuclear Information System (INIS)

    Amador G, R.; Gonzalez M, V.M.

    1993-01-01

    The National Commission of Nuclear Safety and Safeguards (CNSNS) requires to have calculation tools which allows it to make analysis independent of the behavior of the reactor core of Laguna Verde nuclear power plant (CNLV) with the purpose to support the evaluation and discharge activities of the fuel recharges licensing. The software package Fms (Fuel Management System) allows to carry out an analysis of the core of the BWR type reactors along the operation cycle to detect possible anomalies and/or helping in the fuel management. In this work it is reproduced the flow-power for the CNLV using the Presto code of the Fms software package. The comparison of results with the map used by the operators of CNLV shows good agreement between them. Another exercise carried out was the changes study that the axial and radial power outlines undergo as well as the thermohydraulic parameters (LHGR, APLHGR, CPR) when moving a control rod. The obtained results show that is had the experience to effect analysis of the reactor behavior using the Presto-Fms code therefore the study of the rest of the software package for the obtention of nuclear parameters used in this code is recommended. (Author)

  2. Applications of the monitor of loose parts in the cycle 6 of the Laguna Verde Unit 2 power plant; Aplicaciones del monitor de partes sueltas en el ciclo 6 de la Unidad 2 de la central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Calleros, G.; Mendez, A.; Gomez, R.A. [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Veracruz (Mexico); Castillo, R.; Bravo, J.M. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)]. E-mail: gcm9acpp@cfe.gob.mx

    2004-07-01

    The monitor of loose parts (Loose Parts Monitoring System) installed in the Unit 2 of the Laguna Verde Central is a tool to detect strange objects or parts loose in the system of refrigeration of the reactor that could be impacted in the walls of the recirculation knots or in the internal of the reactor. In this work two applications are shown carried out with the Monitor of Loose Parts, determining the characteristics of the stable nominal conditions, those which when changing, they are used to diagnose during the Cycle 6 of the Unit 2, failures in the components of the the recirculation circuits or to identify mechanical vibrations of the recirculation knots induced by a flow of recirculation bistable associated to operative conditions of the reactor. (Author)

  3. Electrical systems at the nuclear power plant of Laguna Verde after the event in Fukushima; Sistemas electricos en la central nucleoelectrica Laguna Verde despues del evento de Fukushima

    Energy Technology Data Exchange (ETDEWEB)

    Lopez J, J. F., E-mail: jflopez@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Jose M. Barragan 779, Col. Narvarte, 03020 Ciudad de Mexico (Mexico)

    2016-09-15

    During the event at the nuclear power plant of Fukushima Daichii (Japan), the electrical systems were affected both Onsite and Offsite, which were lost for a long time with irreversible consequences. Therefore, the Mexican Regulatory Body known as the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) has taken various actions to review the current capacity of the electrical systems at the nuclear power plant of Laguna Verde (NPP-LV) before an event beyond the design bases. The CNSNS made special inspections to the NPP-LV to verify the current capacity of the electrical systems of Ac and Dc; as a result of the inspections, requirements were generated that must be met to demonstrate that has the capacity to deal with events beyond the design bases. In addition, CNSNS has participated in the Ibero-American Forum to deal with resistance testing. Is important to note that prior to the event at the nuclear power plant of Fukushima, the NPP-LV had implemented 1) the project Extended Power Increase in both Units of the NPP-LV, and 2) the Generic Charter 2006-02, both issues are considered contributions in the robustness of electrical systems. But it is also important to mention that the US Nuclear Regulatory Commission will soon issue mitigation strategies for a Station Blackout event, which could involve new actions at nuclear power plants. Based on the aforementioned, the CNSNS concludes that all the actions being taken contribute to the strengthening of the NPP-LV electrical systems, in order to increase their reliability, safety and operation when these are required to deal with events beyond the design bases as the event occurred in Fukushima Daichii and avoid as far as possible, damage in the reactor cores of the NPP-LV. (Author)

  4. Preliminary analysis of an hydrogen generator system based on nuclear energy in the Laguna Verde site

    International Nuclear Information System (INIS)

    Flores y Flores, A.; Francois L, J.L.

    2003-01-01

    The shortage of fossil fuels in the next future, as well as the growing one demand of energetics and the high cost of the production of alternating fuels, it forces us to take advantage of to the maximum the fossil fuel with the one which we count and to look for the form of producing alternating fuels at a low cost and better even if these supply sources are reliable and non pollutants. It is intended a solution to the shortage of fuel; to use the thermal energy liberated of some appropriate nuclear reactor to be able to obtain a fuel but clean and relatively cheap as it is the hydrogen. In the first place the methods were looked for to produce hydrogen using thermal energy, later it was analyzed the temperature liberated by the existent nuclear reactors as well as the advanced designs, according to this liberated temperature settled down that the methods but feasible to produce hydrogen its were the one of reformed with water stream of the natural gas (methane) and the other one of the S-I thermochemical cycle, and the nuclear reactors that give the thermal energy for this production they are those of gas of high temperature. Once established the processes and the appropriate reactors, it was analyzed the site of Laguna Verde, with relationship to the free space to be able to place the reactor and the plant producer of hydrogen, as well as the direction in which blow the dominant winds and the near towns to the place, it was carried out an analysis of some explosion of tanks that could store hydrogen and the damage that its could to cause depending from the distance to which its were of the fire. Finally it was carried out an evaluation of capital and of operation costs for those two methods of hydrogen production. (Author)

  5. Actinides inventory of the nuclear power plant of Laguna Verde Unit 1

    International Nuclear Information System (INIS)

    Martinez C, E.; Ramirez S, J. R.; Alonso V, G.

    2013-10-01

    At the present time 435 nuclear power reactors exist for the electricity generation operating in the world and 63 in construction. Mexico has two reactors type BWR in the nuclear power plant of Laguna Verde. The nuclear fuel that is used in the nuclear reactors is retired of the reactor core when the energy that this contained has been extracted. This used fuel is known as spent nuclear fuel, the problem with this fuel is that was irradiated inside the reactor and continuous emitting a high radiation, as well as a significant heat quantity when being extracted, for what is necessary to maintain it in cooling and with some shielding to be protected of the radiation that emits. This objective is achieved confining the fuel in the spent nuclear fuel pool, where it is cooled and the same pool provides the necessary shielding to maintain the surroundings in safety radiation levels for the personnel that work in the power plant. An inconvenience of the pools is its limited storage capacity and that after certain time is necessary to remove the fuel, according to the established regulation to continue operating. To correct this inconvenience, two alternatives of spent fuel disposition exist, 1) the final disposition in deep geologic repositories and 2) the reprocessing and recycled of spent fuel. Each alternative presents its particularities and specific problems; however taking many years to be able to implement anyone of them. To carry out the second option, is indispensable to estimate the total mass of actinides generated in the spent nuclear fuel, that which represents to develop a methodology for it, this action is the main purpose of the present work. Inside our calculation method was necessary to appeal to diverse computation tools as the codes Origin-S and Keno V.a. Later on the obtained were compared with a problem type Benchmark, being obtained a smaller absolute error to 1.0%. (Author)

  6. Applications of the monitor of loose parts in the cycle 6 of the Laguna Verde Unit 2 power plant

    International Nuclear Information System (INIS)

    Calleros, G.; Mendez, A.; Gomez, R.A.; Castillo, R.; Bravo, J.M.

    2004-01-01

    The monitor of loose parts (Loose Parts Monitoring System) installed in the Unit 2 of the Laguna Verde Central is a tool to detect strange objects or parts loose in the system of refrigeration of the reactor that could be impacted in the walls of the recirculation knots or in the internal of the reactor. In this work two applications are shown carried out with the Monitor of Loose Parts, determining the characteristics of the stable nominal conditions, those which when changing, they are used to diagnose during the Cycle 6 of the Unit 2, failures in the components of the the recirculation circuits or to identify mechanical vibrations of the recirculation knots induced by a flow of recirculation bistable associated to operative conditions of the reactor. (Author)

  7. Validation of the thermal balance of Laguna Verde turbine under conditions of extended power increase; Validacion del balance termico de turbina de Laguna Verde en condiciones de aumento de potencia extendido

    Energy Technology Data Exchange (ETDEWEB)

    Castaneda G, M. A.; Cruz B, H. J.; Mercado V, J. J.; Cardenas J, J. B.; Garcia de la C, F. M., E-mail: miguel.castaneda01@cfe.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Carretera Cardel-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2012-10-15

    The present work is a continuation of the task: Modeling of the vapor cycle of Laguna Verde with the PEPSE code to conditions of thermal power licensed at present (2027 MWt) in which the modeling of the vapor cycle of the nuclear power plant of Laguna Verde was realized with PEPSE code (Performance Evaluation of Power System Efficiencies). Once reached the conditions of nominal operation of extended power increase, operating both units to 2371 MWt; after the tests phase of starting-up and operation is necessary to carry out a verification of the proposed design of the vapor cycle for the new operation conditions. All this, having in consideration that the vapor cycle designer only knows the detail of the prospective performance of the main turbine, for all the other components (for example pumps, heat inter changers, valves, reactor, humidity separators and re-heaters, condensers, etc.) makes generic suppositions based on engineering judgment. This way carries out the calculations of thermal balance to determine the guaranteed gross power. The purpose of the present work is to comment the detail of the validation carried out of the specific thermal balance (thermal kit) of the nuclear power plant, making use of the design characteristics of the different components that conform the vapor cycle. (Author)

  8. Modernization of electric power systems of the Laguna Verde Nuclear Power Plant; Modernizacion de los sistemas electricos de potencia de la Central Nuclear de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Gabaldon, M. A.; Gonzalez, J. J.; Prieto, I.

    2011-07-01

    The Power Increase Project of Laguna Verde Nuclear Plant has entailed the replacement, in one unique outage, of the main power electrical systems of the Plant (Isolated Phase Bars, Generator Circuit Breaker and Main Transformer) as well as the replacement of the Turbo-group. The simultaneous substitution of these entire system has never been done by any other Plant in the world, representing an engineering challenge that embraced the design of the new equipment up to the planning, coordination and management of the construction and commissioning works, which were successfully carried out by Iberdrola within the established outage period /47 days) for both units. (Author)

  9. Calculating of radiation doses in rutinary unloads of liquid wastes from Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Molina, G.

    1985-01-01

    Utilization of nuclear energy to produce or generate electricity is a growing practice in the world, since it represent an economic and safe option to replace fossil fuels. During operation of nuclear power plants, radioactive materials are produced. A small fraction of these material are released to environment in the form of liquid or gaseous effluents. Estimation of radiation doses causing by effluents release has three purposes. During design phase of a nuclear station it is useful to adapt the wastes treatment systems to acceptable limits. During licensing phase, the regulator organism verifies the design of nuclear station effectuating estimation of doses. Finally, during operation of a nuclear station, before every unload of radioactive effluents, radiation doses should be evaluate in order to fulfill technical specifications, which limit the release of radioactive materials to environment. 1. To perform calculations of individual doses due to liquid radioactive effluents unload in units 1 and 2 of Laguna Verde nuclear power plant (In licensing phase). 2. To perform a parametric study of the effect of unload recirculation over individual dose, since recirculation has two principal effects: thermodynamical effects in nuclear station and radioactivity concentration, the last can affect the fullfilment of dose limits. 3. To perform the calculation of collective doses causes by unloads of liquid effluents within a radius of 80 Kms. of nuclear station caused by unload of liquid radioactive effluents during normal operation of nuclear power plant and does not include doses caused during accident conditions. In Mexico the organism in charge of regulation of peaceful uses of nuclear energy is Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) and for Laguna Verde licensing, the regulations of country who manufactured the reactor was adopted, it is to say United States of America. In Appendix 'C' units used along this work are explained. Unless another

  10. Seismic qualification tests of fans of the NPP of Laguna Verde U-1 and U-2

    International Nuclear Information System (INIS)

    Jarvio C, G.; Garcia H, E. E.; Arguelles F, R.; Vela H, A.; Naranjo U, J. L.

    2013-10-01

    This work presents the results of the seismic qualification tests applied to the fans that will be installed in the control panels of the three divisions of the diesel generators of the nuclear power plant (NPP) of Laguna Verde, Unit-1 and Unit-2. This seismic qualification process of the fans was carried out using two specimens that were tested in the seismic table (vibrating) of the Engineering Institute of Universidad Nacional Autonoma de Mexico (UNAM), in accordance with the requirements of the standard IEEE 344-1975, to satisfy the established requirements of seismic qualification in the technical specifications and normative documents required by the nuclear standards, in order to demonstrate its application in the diesel generators Divisions I, II and III of the NPP. The seismic qualification tests were developed on specimens that were retired of the NPP of Laguna Verde recently with a service life of 7.75 years. (Author)

  11. Start up and commercial operation of Laguna Verde nuclear power plant. Unit 1

    International Nuclear Information System (INIS)

    Torres Ramirez, J.F.

    1991-01-01

    Prior to start up of Laguna Verde nuclear power plant preoperational tests and start tests were performed and they are described in its more eminent aspects. In relation to commercial operation of nuclear station a series of indicator were set to which allow the measurement of performance in unit 1, in areas of plant efficiency and personal safety. Antecedents. Laguna Verde station is located in Alto Lucero municipality in Veracruz state, 70 kilometers north-northeast from port of Veracruz and a 290 kilometers east-northeast from Mexico city. The station consist of two units manufactured by General Electric, with a nuclear system of vapor supply also called boiling water (BWR/5), and with a system turbine-generator manufactured by Mitsubishi. Each unit has a nominal power of 1931 MWt and a level design power of 675 Mwe and a net power of 654 Electric Megawatts

  12. Analysis of internal events for the Unit 1 of the Laguna Verde Nuclear Power Station. Appendixes

    International Nuclear Information System (INIS)

    Huerta B, A.; Lopez M, R.

    1995-01-01

    This volume contains the appendices for the accident sequences analysis for those internally initiated events for Laguna Verde Unit 1, Nuclear Power Plant. The appendix A presents the comments raised by the Sandia National Laboratories technical staff as a result of the review of the Internal Event Analysis for Laguna Verde Unit 1 Nuclear Power Plant. This review was performed during a joint Sandia/CNSNS multi-day meeting by the end 1992. Also included is a brief evaluation on the applicability of these comments to the present study. The appendix B presents the fault tree models printed for each of the systems included and.analyzed in the Internal Event Analysis for LVNPP. The appendice C presents the outputs of the TEMAC code, used for the cuantification of the dominant accident sequences as well as for the final core damage evaluation. (Author)

  13. Analysis of internal events for the Unit 1 of the Laguna Verde Nuclear Power Station. Appendixes

    International Nuclear Information System (INIS)

    Huerta B, A.; Lopez M, R.

    1995-01-01

    This volume contains the appendices for the accident sequences analysis for those internally initiated events for Laguna Verde Unit 1, Nuclear Power Plant. The appendix A presents the comments raised by the Sandia National Laboratories technical staff as a result of the review of the Internal Event Analysis for Laguna Verde Unit 1 Nuclear Power Plant. This review was performed during a joint Sandia/CNSNS multi-day meeting by the end 1992. Also included is a brief evaluation on the applicability of these comments to the present study. The appendix B presents the fault tree models printed for each of the systems included and analyzed in the Internal Event Analysis for LVNPP. The appendice C presents the outputs of the TEMAC code, used for the cuantification of the dominant accident sequences as well as for the final core damage evaluation. (Author)

  14. Multivariate analysis in the frequency mastery applied to the Laguna Verde Central; Analisis multivariable en el dominio de la frecuencia aplicado a la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Castillo D, R.; Ortiz V, J. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Calleros M, G. [CFE, Central Nucleoelectrica de Laguna Verde, carretera Nautla-Cardel Km. 42.5, Alto Lucero, Veracruz (Mexico)]. e-mail: rcd@nuclear.inin.mx

    2006-07-01

    The noise analysis is an auxiliary tool in the detection of abnormal operation conditions of equipment, instruments or systems that affect to the dynamic behavior of the reactor. The spectral density of normalized power has usually been used (NPSD, by its initials in English), to watch over the behavior of some components of the reactor, for example, the jet pumps, the recirculation pumps, valves of flow control in the recirculation knots, etc. The behavior change is determined by individual analysis of the NPSD of the signals of the components in study. An alternative analysis that can allow to obtain major information on the component under surveillance is the multivariate autoregressive analysis (MAR, by its initials in English), which allows to know the relationship that exists among diverse signals of the reactor systems, in the time domain. In the space of the frequency, the relative contribution of power (RPC for their initials in English) it quantifies the influence of the variables of the systems on a variable of interest. The RPC allows, therefore that for a peak shown in the NPSD of a variable, it can be determine the influence from other variables to that frequency of interest. This facilitates, in principle, the pursuit of the important physical parameters during an event, and to study their interrelation. In this work, by way of example of the application of the RPC, two events happened in the Laguna Verde Central are analyzed: the rods blockade alarms by high scale in the monitors of average power, in which it was presents a power peak of 12% of width peak to peak, and the power oscillations event. The main obtained result of the analysis of the control rods blockade alarm event was that it was detected that the power peak observed in the signals of the average power monitors was caused by the movement of the valve of flow control of recirculation of the knot B. In the other oscillation event the results its show the mechanism of the oscillation of

  15. Estimation of seismic return periods in the Laguna Verde nuclear plant

    International Nuclear Information System (INIS)

    Flores R, J.H.

    1992-01-01

    The study of seismic risk in the area of the Laguna Verde Nucleo electric plant (PNLV) and its surroundings, one carries out estimating the different return periods and the occurrence probability in different intervals of time (5, 75, 100, 125, 150 years starting from the distribution of first type of Gumbel (G1) of extreme values (Burton, 1986), the value that was used to evaluate the useful life of the PNLV was of 50 years, the other periods will be occupy to evaluate 'temporal' nuclear cemeteries, that is to say for diminish the radioactive activity of the fuel assemblies already burned in the reactor pool or in a near place to the place. The seismic data that were used for the analysis were of the seismic catalog that it was elaborated from (1920-1982), around the place whose seismic half magnitude was of 5 grades Richter and a depth 65 km, these earthquakes are classified as shallow earthquakes, which are located in the continental plaque of North-America, these they are induced by the efforts of push of the plaque of Cocos, existing 36% of intermediate and 2 of deep earthquakes. (Author)

  16. Fuel failure at the Laguna Verde unit 1- during Cycle 4

    International Nuclear Information System (INIS)

    Espinosa Vega, Juan Manuel

    1996-01-01

    The present work describes the event occurred at the Laguna Verde nuclear power plants Unit 1 during its fourth cycle ensembles; the first failure, by means of a test of power suppression, and the second one, during the sipping accomplished in the four refuelling of the unit. Also it describes the re-evaluation of the event accomplished by the licenser, the manufacturer and the Mexican agency

  17. Simulation of the electric systems of the Laguna Verde nuclear power station; Simulacion de los sistemas electricos de la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Lozano, Saul; Ruiz Ponce, Gerardo E [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1992-03-01

    In this article, the electric system models of the Laguna Verde Nuclear Power Station (CNLV) simulator, are presented. These models permit the functioning simulation, in the different operation modes of the main generator (Ruiz and Rodriguez 1991a), of the auxiliaries system and of the substation (Ruiz and Rodriguez 1991b), and of the emergency diesel generators system (Ruiz and Rodriguez 1991c). The general characteristics of such systems, considered as the basis to obtain the representative models, which were developed as modules in an independent way to be integrated in the simulator, are also described. [Espanol] En este articulo, se presenta los modelos de los sistemas electricos del simulador de la Central Laguna Verde (CLV). Estos modelos permiten simular el funcionamiento, en los diferentes modos de operacion del generador principal (Ruiz y Rodriguez, 1991a), del sistema de auxiliares y de la subestacion (Ruiz y Rodriguez, 1991b) y del sistema de generadores diesel de emergencia (Ruiz y Rodriguez, 1991c). Asimismo, se describen las caracteristicas generales de tales sistemas, consideradas como la base para obtener los modelos representativos, los cuales fueron desarrollados como modulos en forma independiente para integrarse al simulador.

  18. The continuous improvement system of nuclear power plant of Laguna Verde; El sistema de mejora continua de la central nucleoelectrica Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Rivera C, A. [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Km. 42.5 Cardel-Nautla, Veracruz (Mexico)], e-mail: arr99999@cfe.gob.mx

    2009-10-15

    This paper describes the continuous improvement system of nuclear power plant of Laguna Verde and the achievements in implementing the same and additionally two study cases are presents. In February 2009 is noteworthy because the World Association of Nuclear Operators we identified as a learning organization, qualification which shows that the continuous improvement system has matured, and this system will expose as I get to learn to capitalize on our own experiences and external experiences diffused by the nuclear industry. In 2007 the management of nuclear power plants integrates its improvement systems and calls it continuous improvement system and is presented in the same extensive report that won the National Quality Award. This system is made up of 5 subsystems operating individually and are also related 1) human performance; 2) referential comparison or benchmarking; 3) self-assessment; 4) corrective action and 5) external operating experience. Five subsystems that plan, generate, capture, manage, communicate and protect the knowledge generated during the processes execution of nuclear power plant of Laguna Verde, as well as from external sources. The target set in 2007 was to increase the intellectual capital to always give response to meeting the security requirements, but creating a higher value to quality, customer, environment protection and society. In brief each of them, highlighting the objective, expectations management, implementation and some benefits. At the end they will describe two study cases selected to illustrate these cases as the organization learns by their continuous improvement system. (Author)

  19. Analysis of the three dimensional core kinetics NESTLE code coupling with the advanced thermo-hydraulic code systems, RELAP5/SCDAPSIM and its application to the Laguna Verde Central reactor; Analisis para el acoplamiento del codigo NESTLE para la cinetica tridimensional del nucleo al codigo avanzado de sistemas termo-hidraulicos, RELAP5/SCDAPSIM y su aplicacion al reactor de la CNLV

    Energy Technology Data Exchange (ETDEWEB)

    Salazar C, J H; Nunez C, A [CNSNS, Dr. Jose Ma. Barragan No. 779, Col. Narvarte, 03020 Mexico D.F. (Mexico); Chavez M, C [UNAM, Facultad de Ingenieria, DEPFI Campus Morelos (Mexico)

    2004-07-01

    The objective of the written present is to propose a methodology for the joining of the codes RELAP5/SCDAPSIM and NESTLE. The development of this joining will be carried out inside a doctoral program of Engineering in Energy with nuclear profile of the Ability of Engineering of the UNAM together with the National Commission of Nuclear Security and Safeguards (CNSNS). The general purpose of this type of developments, is to have tools that are implemented by multiple programs or codes such a that systems or models of the three-dimensional kinetics of the core can be simulated and those of the dynamics of the reactor (water heater-hydraulics). In the past, by limitations for the calculation of the complete answer of both systems, the developed models they were carried out for separate, putting a lot of emphasis in one but neglecting the other one. These methodologies, calls of better estimate, will be good to the nuclear industry to evaluate, with more high grades of detail, the designs of the nuclear power plant (for modifications to those already existent or for new concepts in the designs of advanced reactors), besides analysing events (transitory and have an accident), among other applications. The coupled system was applied to design studies and investigation of the Laguna Verde Nuclear power plant (CNLV). (Author)

  20. Using NJOY99 and MCNP4B2 to Estimate the Radiation Damage Displacements per Atom per Second in Steel Within the Boiling Water Reactor Core Shroud and Vessel Wall from Reactor-Grade Mixed-Oxide/Uranium Oxide Fuel for the Nuclear Power Plant at Laguna Verde, Veracruz, Mexico

    International Nuclear Information System (INIS)

    Vickers, Lisa

    2003-01-01

    The government of Mexico has expressed interest in utilizing the Laguna Verde boiling water reactor (BWR) nuclear power plant for the disposition of reprocessed spent uranium oxide (UOX) fuel in the form of reactor-grade mixed-oxide (MOX) fuel. MOX fuel would replace spent UOX fuel as a fraction in the core from 18 to 30% depending on the fuel loading cycle. MOX fuel is expected to increase the neutron fluence, flux, fuel centerline temperature, reactor core pressure, and yield higher energy neutrons.There is concern that a core with a fraction of MOX fuel (i.e., increased 239 Pu wt%) would increase the radiation damage displacements per atom per second (dpa-s -1 ) in steel within the core shroud and vessel wall as compared to only conventional, enriched UOX fuel in the core. The evaluation of radiation damage within the core shroud and vessel wall is a concern because of the potentially adverse affect to personnel and public safety, environment, and operating life of the reactor.The primary uniqueness of this paper is the computation of radiation damage (dpa-s -1 ) using NJOY99-processed cross sections for steel within the core shroud and vessel wall. Specifically, the unique radiation damage results are several orders of magnitude greater than results of previous works. In addition, the conclusion of this paper was that the addition of the maximum fraction of one-third MOX fuel to the LV1 BWR core did significantly increase the radiation damage in steel within the core shroud and vessel wall such that without mitigation of radiation damage by periodic thermal annealing or reduction in operating parameters such as neutron fluence, core temperature, and pressure, it posed a potentially adverse affect to the personnel and public safety, environment, and operating life of the reactor

  1. Genetic structure of populations of Drosophila melanogaster natives from Laguna Verde, Veracruz; Estructura genetica de poblaciones de Drosophila melanogaster originarias de Laguna Verde, Veracruz

    Energy Technology Data Exchange (ETDEWEB)

    Salceda, V M [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-07-01

    The genetic variability hidden present in natural populations of Drosophila melanogaster, it has been broadly analyzed, and it is a tool that allows to detect differences among the different populations of this species, so much of natural nature as experimental. In this occasion we use it to see if differences exist in two neighboring populations inside the Laguna Verde nuclear power plant, Veracruz, and this way to suggest, of having differences in the mount of the relative frequencies of lethal genes, semi lethals and normal, be due to the radioactive emanations product of the reactors operation of the plant. Its were took samples of flies in both towns during three successive seasons and they were transported to the laboratory of the ININ where they were carried out the tests to determine the frequency of the different types of genes. This was made by means of the denominated technique C y L / Pm that allows by means of a cross series with a stump marker to obtain, in the third generation, in isolated form the different types of genes and this way to calculate their relative frequencies. The study understands the analysis of 299 chromosomes extracted from the populations, of those that 95 correspond at the control population and 204 to the experimental one. As a result of the analysis we find that 30.52 percent of the genes of the population witness contains detrimental genes (sum of the lethal plus the semi lethal genes) as long as in the experimental population this value corresponds to 23.03 percent. In accordance with this information was not significant difference among the studied populations. A similar analysis, but now comparing the seasons, (summer against winter), it showed significant difference to 5% with regard to the lethal genes frequency only in the population witness. These results indicate the absence of damage, however it is necessary to consider that this can be due to that indeed there is not him or that the investigation protocol is not

  2. Analysis of internal events for the Unit 1 of the Laguna Verde nuclear power station; Analisis de eventos internos para la Unidad 1 de la Central Nucleolelectrica de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Huerta B, A.; Aguilar T, O.; Nunez C, A.; Lopez M, R. [Comision Nacional de Seguridad Nuclear y Salvaguardias, 03000 Mexico D.F. (Mexico)

    1993-07-01

    This volume presents the results of the starter event analysis and the event tree analysis for the Unit 1 of the Laguna Verde nuclear power station. The starter event analysis includes the identification of all those internal events which cause a disturbance to the normal operation of the power station and require mitigation. Those called external events stay beyond the reach of this study. For the analysis of the Laguna Verde power station eight transient categories were identified, three categories of loss of coolant accidents (LOCA) inside the container, a LOCA out of the primary container, as well as the vessel break. The event trees analysis involves the development of the possible accident sequences for each category of starter events. Events trees by systems for the different types of LOCA and for all the transients were constructed. It was constructed the event tree for the total loss of alternating current, which represents an extension of the event tree for the loss of external power transient. Also the event tree by systems for the anticipated transients without scram was developed (ATWS). The events trees for the accident sequences includes the sequences evaluation with vulnerable nucleus, that is to say those sequences in which it is had an adequate cooling of nucleus but the remoting systems of residual heat had failed. In order to model adequately the previous, headings were added to the event tree for developing the sequences until the point where be solved the nucleus state. This process includes: the determination of the failure pressure of the primary container, the evaluation of the environment generated in the reactor building as result of the container failure or cracked of itself, the determination of the localization of the components in the reactor building and the construction of boolean expressions to estimate the failure of the subordinated components to an severe environment. (Author)

  3. Development of an interactive model of the Laguna Verde nuclear power plant based on the RELAP/SCDAP code; Desarrollo del modelo interactivo de la central nucleoelectrica de Laguna Verde basado en el codigo RELAP/SCDAP

    Energy Technology Data Exchange (ETDEWEB)

    Salazar C, J.H.; Ramos P, J.C.; Salazar S, E.; Chavez M, C. [LAIRN, FI-UNAM, DEPFI Campus Morelos, Jiutepec, Morelos (Mexico)]. e-mail: cchavez2@cableonline.com.mx

    2003-07-01

    The present work describes the development of an interactive model of the Nuclear power plant of Laguna Verde (CNLV) based on the RELAP/SCDAP nuclear code, and it incorporation to a classroom simulator. The functional prototype it allows to make evaluations for operational transients and postulates accidents, with capacitation purposes, training, analysis and design. It emphasizes on the methodology used to establish the inter activity. Such methodology, is based on a modular structure in the one that multiple processes can be executed in an independent way and where the generated information is stored in segments of shared memory (characteristic that allows the UNIX operating system) and sent to the different processes by means of communication routines developed in C programming language. The utility of the system is demonstrated by means of the use of interactive display graphics (mimic diagrams, pictorials and tendency graphics) for the simultaneous dynamic visualization of the variables more significant that involve to the pattern of a transitory event type (for example failure of the controller of feeding water in a BWR reactor). Near with the interactive module, it was developed a model of the reactor of the CNLV for the code of better estimation RELAP/SCDAP. Finally the evaluation of the model is described, where it is interpreted in general form the behavior of those main variables that describe the stationary state, corroborating that follow the same tendency that those reported in the FSAR (Final Safety Analysis Report) of the Laguna Verde plant. The obtained results allow to conclude that the made development was satisfactory and that it presents enormous advantages regarding the capacity and time of analysis when using tools of visualization in real time of execution. (Author)

  4. Development of an interactive model of the Laguna Verde nuclear power plant based on the RELAP/SCDAP code

    International Nuclear Information System (INIS)

    Salazar C, J.H.; Ramos P, J.C.; Salazar S, E.; Chavez M, C.

    2003-01-01

    The present work describes the development of an interactive model of the Nuclear power plant of Laguna Verde (CNLV) based on the RELAP/SCDAP nuclear code, and it incorporation to a classroom simulator. The functional prototype it allows to make evaluations for operational transients and postulates accidents, with capacitation purposes, training, analysis and design. It emphasizes on the methodology used to establish the inter activity. Such methodology, is based on a modular structure in the one that multiple processes can be executed in an independent way and where the generated information is stored in segments of shared memory (characteristic that allows the UNIX operating system) and sent to the different processes by means of communication routines developed in C programming language. The utility of the system is demonstrated by means of the use of interactive display graphics (mimic diagrams, pictorials and tendency graphics) for the simultaneous dynamic visualization of the variables more significant that involve to the pattern of a transitory event type (for example failure of the controller of feeding water in a BWR reactor). Near with the interactive module, it was developed a model of the reactor of the CNLV for the code of better estimation RELAP/SCDAP. Finally the evaluation of the model is described, where it is interpreted in general form the behavior of those main variables that describe the stationary state, corroborating that follow the same tendency that those reported in the FSAR (Final Safety Analysis Report) of the Laguna Verde plant. The obtained results allow to conclude that the made development was satisfactory and that it presents enormous advantages regarding the capacity and time of analysis when using tools of visualization in real time of execution. (Author)

  5. Negative sequence relay applied to generator 1 of the Laguna Verde nuclear power plant; Aplicacion de un relevador de secuencia negativa en el generador 1 de la central de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Diaz de la Serna P, Enrique [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1988-12-31

    The rotor of a synchronous generator can be dangerously heated in a short time by stator current unbalance, therefore it must be protected with a specific relay. This article discusses the protection and the adjustments selected for Unit 1 of the Comision Federal de Electricidad Laguna Verde Nuclear Nuclear Power Station. [Espanol] El rotor de un generador sincrono puede calentarse peligrosamente en un tiempo corto debido a desbalance de corrientes en el estator, por lo que debe protegerse con un relevador especifico. En este articulo se describen la proteccion y los ajustes seleccionados para la unidad 1, de la central nucleoelectrica Laguna Verde de la Comision Federal de Electricidad.

  6. Study of environmental noise in a BWR plant like the Nuclear Power Plant Laguna Verde

    International Nuclear Information System (INIS)

    Tijerina S, F.; Cruz G, M.; Amador C, C.

    2013-10-01

    In all industry type the health costs generated by the noise are high, because the noise can cause nuisance and to harm the capacity to work when causing tension and to perturb the concentration, and in more severe cases to reach to lose the sense of the hearing in the long term. The noise levels in the industry have been designated for the different types of use like residential, commercial, and industrial and silence areas. The noise can cause accidents when obstructing the communications and alarm signs. For this reason the noise should be controlled and mitigated, at a low level as reasonably is possible, taking into account that the noise is an acoustic contamination. The present study determines a bases line of the environmental noise levels in a nuclear power plant BWR-5 as Laguna Verde, (like reference) to be able to determine and to give pursuit to the possible solutions to eliminate or to limit the noise level in the different job areas. The noise levels were registered with a meter of integrative noise level (sonometer) and areas of noise exposure levels mapping the general areas in the buildings were established, being the registered maximum level of 96.94 dba in the building of the Reactor-elevation 0.65 m under the operation conditions of Extended Power Up rate (EPU) of 120% PTN. Knowing that the exposition to noises and the noise dose in the job place can influence in the health and in the safety of the workers, are extensive topics that they should be analyzed for separate as they are: to) the effects in the health of the exposure to the noise, b) how measuring the noise, c) the methods and technologies to combat and to control the noise in the industry by part of engineering area and d) the function of the industrial safety bodies as delegates of the health and safety in the task against the noise in the job. (author)

  7. Electrical systems at the nuclear power plant of Laguna Verde after the event in Fukushima

    International Nuclear Information System (INIS)

    Lopez J, J. F.

    2016-09-01

    During the event at the nuclear power plant of Fukushima Daichii (Japan), the electrical systems were affected both Onsite and Offsite, which were lost for a long time with irreversible consequences. Therefore, the Mexican Regulatory Body known as the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) has taken various actions to review the current capacity of the electrical systems at the nuclear power plant of Laguna Verde (NPP-LV) before an event beyond the design bases. The CNSNS made special inspections to the NPP-LV to verify the current capacity of the electrical systems of Ac and Dc; as a result of the inspections, requirements were generated that must be met to demonstrate that has the capacity to deal with events beyond the design bases. In addition, CNSNS has participated in the Ibero-American Forum to deal with resistance testing. Is important to note that prior to the event at the nuclear power plant of Fukushima, the NPP-LV had implemented 1) the project Extended Power Increase in both Units of the NPP-LV, and 2) the Generic Charter 2006-02, both issues are considered contributions in the robustness of electrical systems. But it is also important to mention that the US Nuclear Regulatory Commission will soon issue mitigation strategies for a Station Blackout event, which could involve new actions at nuclear power plants. Based on the aforementioned, the CNSNS concludes that all the actions being taken contribute to the strengthening of the NPP-LV electrical systems, in order to increase their reliability, safety and operation when these are required to deal with events beyond the design bases as the event occurred in Fukushima Daichii and avoid as far as possible, damage in the reactor cores of the NPP-LV. (Author)

  8. Internal event analysis for Laguna Verde Unit 1 Nuclear Power Plant. Accident sequence quantification and results

    International Nuclear Information System (INIS)

    Huerta B, A.; Aguilar T, O.; Nunez C, A.; Lopez M, R.

    1994-01-01

    The Level 1 results of Laguna Verde Nuclear Power Plant PRA are presented in the I nternal Event Analysis for Laguna Verde Unit 1 Nuclear Power Plant, CNSNS-TR 004, in five volumes. The reports are organized as follows: CNSNS-TR 004 Volume 1: Introduction and Methodology. CNSNS-TR4 Volume 2: Initiating Event and Accident Sequences. CNSNS-TR 004 Volume 3: System Analysis. CNSNS-TR 004 Volume 4: Accident Sequence Quantification and Results. CNSNS-TR 005 Volume 5: Appendices A, B and C. This volume presents the development of the dependent failure analysis, the treatment of the support system dependencies, the identification of the shared-components dependencies, and the treatment of the common cause failure. It is also presented the identification of the main human actions considered along with the possible recovery actions included. The development of the data base and the assumptions and limitations in the data base are also described in this volume. The accident sequences quantification process and the resolution of the core vulnerable sequences are presented. In this volume, the source and treatment of uncertainties associated with failure rates, component unavailabilities, initiating event frequencies, and human error probabilities are also presented. Finally, the main results and conclusions for the Internal Event Analysis for Laguna Verde Nuclear Power Plant are presented. The total core damage frequency calculated is 9.03x 10-5 per year for internal events. The most dominant accident sequences found are the transients involving the loss of offsite power, the station blackout accidents, and the anticipated transients without SCRAM (ATWS). (Author)

  9. Participation of the ININ in the external radiological emergency plan of the Laguna Verde power plant

    International Nuclear Information System (INIS)

    Martinez S, R.; Cervini L, A.

    1991-01-01

    The planning of performances in radiological emergencies, with the object of reducing the consequences as much as possible on the population to accidental liberations of radioactive material coming from Nuclear power plant, it has been of main interest in the nuclear community in the world. In Mexico it has not been the exception, since with the setting in march of the Laguna Verde nuclear power plant exists an executive program of planning for emergencies that it outlines the activities to follow trending to mitigate the consequences that are derived of this emergency. As integral part of this program this the External Plan of Radiological Emergency (PERE) that covers the emergencies that could leave the frontiers of the Laguna Verde power plant. In the PERE it settles down the planning, address and control of the preparation activities, response and recovery in emergencies, as well as the organization and coordination of the institutions that participate. The National Institute of Nuclear Research (ININ), like integral part of these institutions in the PERE, has an infrastructure that it allows to participate in the plan in a direct way in the activities of 'Control of the radiological exhibition the response personnel and control of water and foods' and of support way and consultant ship in the activities of 'Monitoring, Classification and decontamination of having evaluated' and 'Specialized medical radiological attention'. At the moment the ININ has a radiological mobile unit and this conditioning a second mobile unit to carry out part of the activities before mentioned; also accounts with 48 properly qualified people that directly intervene in the plan. In order to guarantee an adequate response in the PERE an organization it has been structured like that of the annex as for the personnel, transport, team, procedures and communication system, with the objective always of guaranteeing the security and the population's health in emergency situations in the

  10. Calculating of radiation doses in rutinary unloads of liquid wastes from Laguna Verde nuclear power plant.; Calculo de las dosis de radiacion debidas a las descargas rutinarias de desechos liquidos de la central nucleoelectrica de Laguna Verde.

    Energy Technology Data Exchange (ETDEWEB)

    Molina, G

    1986-12-31

    Utilization of nuclear energy to generate electricity is increasingly being used to replace fossil fuels. During operation of nuclear power plants, radioactive materials are produced, a small fraction of which are released to environment as liquid or gaseous effluents. Estimation of radiation doses caused by effluents release has three purposes. During design phase of a nuclear station it is useful to adapt the wastes treatment systems to acceptable limits. During licensing phase, the regulator organism verifies the design of nuclear station effectuating estimation of doses. Finally, during operation, before every unload of radioactive effluents, radiation doses should be evaluated in order to fulfill technical specifications limiting the release of radioactive materials to environment. 1. To perform calculations of individual doses due to liquid radioactive effluents unload in units 1 and 2 of Laguna Verde nuclear power plant (In licensing phase). 2. To perform a parametric study of the effect of unload recirculation over individual dose, since recirculation has two principal effects: thermodynamical effects in nuclear station and radioactivity concentration; the last can affect the fullfilment of dose limits. 3. To perform the calculation of collective doses causes by unloads of liquid effluents within a radius of 80 km of the plant caused by unload of liquid radioactive effluents during normal operation and does not include doses during accident conditions. In Mexico the organism in charge of regulation of peaceful uses of nuclear energy is Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) and for Laguna Verde licensing, the regulations of the country who manufactured the reactor (USA). In Appendix C, units are explained.

  11. Quality assurance evolution at Laguna Verde Nuclear Power Plant Unit 1 and 2, regulatory aspects

    International Nuclear Information System (INIS)

    Leon Martinez, Cenobia

    1996-01-01

    Quality Assurance (QA) in Mexico started with the construction of the Laguna Verde Nuclear Power Plant. The Nuclear Regulatory Body, based in the adopted regulation, required the use of Quality Assurance in the design, construction and operation of the Plant. This paper describes the evolution of QA from its beginnings, through its developing phase up to this time, and shows the role of the Regulatory Body, which has participated actively in the implantation of QA in a properly manner, enforcing the utility in avoiding deviations and non-compliancies with the established regulation. (author)

  12. Participation of the research institutes in the safety aspects of the Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Sanchez G, J.

    1991-01-01

    The main activities undertaken by two research institutes of Mexico, the Instituto de Investigaciones Electricas and the Instituto Nacional de Investigaciones Nucleares, related to the safety of the Laguna Verde Nuclear Power Plant, are described. Among these activities, the development of a system for data acquisition and analysis during pre-operational tests, the design and construction of a full-scope simulator, the in-core fuel management and the establishment of an equipment qualification laboratory, stand out. It is considered that there exists a large potential for further participation. (author)

  13. Modernization of electric power systems of the Laguna Verde Nuclear Power Plant

    International Nuclear Information System (INIS)

    Gabaldon, M. A.; Gonzalez, J. J.; Prieto, I.

    2011-01-01

    The Power Increase Project of Laguna Verde Nuclear Plant has entailed the replacement, in one unique outage, of the main power electrical systems of the Plant (Isolated Phase Bars, Generator Circuit Breaker and Main Transformer) as well as the replacement of the Turbo-group. The simultaneous substitution of these entire system has never been done by any other Plant in the world, representing an engineering challenge that embraced the design of the new equipment up to the planning, coordination and management of the construction and commissioning works, which were successfully carried out by Iberdrola within the established outage period /47 days) for both units. (Author)

  14. Multivariate analysis in the frequency mastery applied to the Laguna Verde Central

    International Nuclear Information System (INIS)

    Castillo D, R.; Ortiz V, J.; Calleros M, G.

    2006-01-01

    The noise analysis is an auxiliary tool in the detection of abnormal operation conditions of equipment, instruments or systems that affect to the dynamic behavior of the reactor. The spectral density of normalized power has usually been used (NPSD, by its initials in English), to watch over the behavior of some components of the reactor, for example, the jet pumps, the recirculation pumps, valves of flow control in the recirculation knots, etc. The behavior change is determined by individual analysis of the NPSD of the signals of the components in study. An alternative analysis that can allow to obtain major information on the component under surveillance is the multivariate autoregressive analysis (MAR, by its initials in English), which allows to know the relationship that exists among diverse signals of the reactor systems, in the time domain. In the space of the frequency, the relative contribution of power (RPC for their initials in English) it quantifies the influence of the variables of the systems on a variable of interest. The RPC allows, therefore that for a peak shown in the NPSD of a variable, it can be determine the influence from other variables to that frequency of interest. This facilitates, in principle, the pursuit of the important physical parameters during an event, and to study their interrelation. In this work, by way of example of the application of the RPC, two events happened in the Laguna Verde Central are analyzed: the rods blockade alarms by high scale in the monitors of average power, in which it was presents a power peak of 12% of width peak to peak, and the power oscillations event. The main obtained result of the analysis of the control rods blockade alarm event was that it was detected that the power peak observed in the signals of the average power monitors was caused by the movement of the valve of flow control of recirculation of the knot B. In the other oscillation event the results its show the mechanism of the oscillation of

  15. Evaluation of the integrity and duration of the Laguna Verde nuclear power plant life- Plant Life Management program (PLIM). TC MEX 04/53 Technical Cooperation Project

    International Nuclear Information System (INIS)

    Arganis J, C.R.; Diaz S, A.; Aguilar T, J.A.

    2006-01-01

    As part of the IAEA TC MEX 04/53 Project 'Evaluation of the integrity and extension of life of the Laguna Verde nuclear power plant Handling Program of plant' whose objective is the one of beginning the actions to apply the methodology of Handling of plant life in the Unit 1 of the Laguna Verde Nucleo electric Central for to obtain the Renovation of License in 2020 the ININ, through the Department of Synthesis and Characterization of materials has carried out more of 20 analysis of susceptibility to the intergranular cracking for corrosion under effort in interns so much of the reactor of the unit 1 like of the unit 2 documenting the current state of components based on the type or types of materials that conform them, to it thermomechanical history, operational and of production, as well as of the particularities associated to its use and operation. For the application of the methodology of life handling of plant 5 structure systems or pilot components were selected, to carry out the programs of handling of the aging and handling of plant life: The encircling of the reactor core (Core Shroud), the reactor pressure vessel (Reactor Pressure Vessel), the primary container (Primary Containment), the recirculation system of feeding water (Reactor Feed Water) and cables. (Author)

  16. Procedure of generation of the ECP database for Laguna Verde

    International Nuclear Information System (INIS)

    Perusquia C, R.

    1992-09-01

    This procedure will be used by the personnel of the Discipline of Nuclear Analysis of the Reactor of CFE to execute PRESTO with the purpose of generating the base for the Estimate of the Position of critical bars during the start up (ECP Database). (Author)

  17. The National Institute of Nuclear Research (ININ) and its participation in the External Radiological Emergency Plans at Laguna Verde Power plant; El ININ y su participacion en el Plan de Emergencia Radiologica Externo de la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Suarez, G. [Instituto Nacional de Investigaciones Nucleares, Departamento de Proteccion Radiologica, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1998-07-01

    In this article it is described the form in which the ININ participates in the External Radiological Emergency Plan at Laguna Verde Power plant. It is set the objective, mission and organization of this plan. The responsibilities and activities that plan has assigned are mentioned also the organization to fulfil them and the obtained results during 9 years of participation. (Author)

  18. Dynamic analysis of the condensate and of the feed water in the Laguna Verde nuclear power station; Analisis dinamico del sistema de condensado y agua de alimentacion de la nucleoelectrica de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Macedo Muth, Javier; Sandoval Pena, Ramon [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1988-12-31

    This article shows a non-lineal mathematical model for the condensate, and feed water systems and for feed water heater drains at the Laguna Verde Nuclear Power Station for its simulation in real time. The model allows the calculation of flows and pressures in all the piping system and equipment that integrate the systems. It was obtained by using the force unbalance in the fluid concept and is capable of reproducing its dynamic behavior through variations induced by the different operation modes and more common failures. The final model objective is to form part of the Laguna Verde simulator that will be used for operator training of this Nuclear Power Plant. [Espanol] En este articulo se muestra un modelo matematico no lineal de los sistemas de condensado, agua de alimentacion y drenes de calentadores de la central nuclear de Laguna Verde para su simulacion en tiempo real. El modelo permite calcular los flujos y las presiones en toda la red de tuberias y equipos que integran los sistemas. Se obtuvo utilizando el concepto de desbalance de fuerzas en el fluido, y es capaz de reproducir su comportamiento dinamico ante variaciones inducidas por los diversos modos de operacion y fallas mas comunes. El objetivo final del modelo es formar parte del simulador de Laguna Verde que se empleara para el adiestramiento de los operadores de dicha central nuclear.

  19. The continuous improvement system of nuclear power plant of Laguna Verde

    International Nuclear Information System (INIS)

    Rivera C, A.

    2009-10-01

    This paper describes the continuous improvement system of nuclear power plant of Laguna Verde and the achievements in implementing the same and additionally two study cases are presents. In February 2009 is noteworthy because the World Association of Nuclear Operators we identified as a learning organization, qualification which shows that the continuous improvement system has matured, and this system will expose as I get to learn to capitalize on our own experiences and external experiences diffused by the nuclear industry. In 2007 the management of nuclear power plants integrates its improvement systems and calls it continuous improvement system and is presented in the same extensive report that won the National Quality Award. This system is made up of 5 subsystems operating individually and are also related 1) human performance; 2) referential comparison or benchmarking; 3) self-assessment; 4) corrective action and 5) external operating experience. Five subsystems that plan, generate, capture, manage, communicate and protect the knowledge generated during the processes execution of nuclear power plant of Laguna Verde, as well as from external sources. The target set in 2007 was to increase the intellectual capital to always give response to meeting the security requirements, but creating a higher value to quality, customer, environment protection and society. In brief each of them, highlighting the objective, expectations management, implementation and some benefits. At the end they will describe two study cases selected to illustrate these cases as the organization learns by their continuous improvement system. (Author)

  20. Validation of a new software version for monitoring of the core of the Unit 2 of the Laguna Verde power plant with ARTS

    International Nuclear Information System (INIS)

    Calleros, G.; Riestra, M.; Ibanez, C.; Lopez, X.; Vargas, A.; Mendez, A.; Gomez, R.

    2005-01-01

    In this work it is intended a methodology to validate a new version of the software used for monitoring the reactor core, which requires of the evaluation of the thermal limits settled down in the Operation Technical Specifications, for the Unit 2 of Laguna Verde with ARTS (improvements to the APRMs, Rod Block Monitor and Technical specifications). According to the proposed methodology, those are shown differences found in the thermal limits determined with the new versions and previous of the core monitoring software. Author)

  1. Modernization of the Electric Power Systems (transformers, rods and switches) in the Laguna Verde Nuclear Power Plant (Mexico)

    International Nuclear Information System (INIS)

    Gonzalez Solarzano, J. J.; Gabaldon Martin, M. A.; Pallisa Nunez, J.; Florez Ordeonez, A.; Fernandez Corbeira, A.; Prieto Diez, I.

    2010-01-01

    Description of the changes made in the Electric Power Systems as a part of the power increase project in the Laguna Verde Nuclear Power Plant (Mexico). The main electrical changes to make, besides the turbo group, are the main generation transformers, the isolated rods and the generation switch.

  2. Genetic structure of populations of Drosophila melanogaster natives from Laguna Verde, Veracruz

    International Nuclear Information System (INIS)

    Salceda, V.M.

    2005-01-01

    The genetic variability hidden present in natural populations of Drosophila melanogaster, it has been broadly analyzed, and it is a tool that allows to detect differences among the different populations of this species, so much of natural nature as experimental. In this occasion we use it to see if differences exist in two neighboring populations inside the Laguna Verde nuclear power plant, Veracruz, and this way to suggest, of having differences in the mount of the relative frequencies of lethal genes, semi lethals and normal, be due to the radioactive emanations product of the reactors operation of the plant. Its were took samples of flies in both towns during three successive seasons and they were transported to the laboratory of the ININ where they were carried out the tests to determine the frequency of the different types of genes. This was made by means of the denominated technique C y L / Pm that allows by means of a cross series with a stump marker to obtain, in the third generation, in isolated form the different types of genes and this way to calculate their relative frequencies. The study understands the analysis of 299 chromosomes extracted from the populations, of those that 95 correspond at the control population and 204 to the experimental one. As a result of the analysis we find that 30.52 percent of the genes of the population witness contains detrimental genes (sum of the lethal plus the semi lethal genes) as long as in the experimental population this value corresponds to 23.03 percent. In accordance with this information was not significant difference among the studied populations. A similar analysis, but now comparing the seasons, (summer against winter), it showed significant difference to 5% with regard to the lethal genes frequency only in the population witness. These results indicate the absence of damage, however it is necessary to consider that this can be due to that indeed there is not him or that the investigation protocol is not

  3. Economic analysis of extended cycles in the Laguna Verde nuclear power plant; Analisis economico de ciclos de extendidos en la Central Nucleoelectrica Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez N, H.; Hernandez M, J.L.; Francois L, J.L. [Facultad de Ingenieria, UNAM, 04510 Mexico D.F. (Mexico)]. E-mail: hermilo@correo.unam.mx

    2004-07-01

    The present work presents a preliminary analysis of economic type of extended cycles of operation of the Unit One in the Laguna Verde nuclear power plant. It is analysed an equilibrium cycle of 18 months firstly, with base to the Plan of Use of Energy of the Federal Commission of Electricity, being evaluated the cost of the energy until the end of the useful life of the plant. Later on an alternative recharge scenario is presented with base to an equilibrium cycle of 24 months, implemented to the beginning of the cycle 11, without considering transition cycles. It is added in both cycles the cost of the substitution energy, considering the unitary cost of the fuel of a dual thermoelectric power station of 350 M We and evaluating in each operation cycle, in both scenarios, the value of the substitution energy. The results show that a reduction of the days of recharge in the cycle of 24 months could make this option but favorable economically. The duration of the period of recharge rebounds in considerable grade in the cost of energy generation for concept of fuel. (Author)

  4. Implementation of the project of equipment reliability in the nuclear power plant of Laguna Verde; Implementacion del proyecto de confiabilidad de equipo en la Central Nucleoelectrica Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Rios O, J. E.; Martinez L, A. G. [CFE, Central Laguna Verde, Subgerencia General de Operacion, Veracruz (Mexico)]. e-mail: jrios@cfe.gob.mx

    2008-07-01

    A equipment is reliable if it fulfills the function for which was designed and when it is required. To implement a project of reliability in a nuclear power plant this associate to a process of continuous analysis of the operation, of the conditions and faults of the equipment. The analysis of the operation of a system, of the equipment of the same faults and the parts that integrate to equipment take to identify the potential causes of faults. The predictive analysis on components and equipment allow to rectify and to establish guides to optimize the maintenance and to guarantee the reliability and function of the same ones. The reliability in the equipment is without place to doubts a wide project that embraces from the more small component of the equipment going by the proof of the parts of reserve, the operation conditions until the operative techniques of analysis. Without place of doubt for a nuclear power plant the taking of decisions based on the reliability of their systems and equipment will be the appropriate for to assure the operation and reliability of the same one. In this work would appear the project of reliability its processes, criteria, indicators action of improvement and the interaction of the different disciplines from the Nuclear Power Plant of Laguna Verde like a fundamental point for it put in operation. (Author)

  5. Relative frequencies of deletereo genes in populations of droshopila Melanogaster from Laguna Verde, Veracruz; Frecuencias relativas de genes deletereos en poblaciones de Drosophila melanogaster originarias de Laguna Verde, Veracruz

    Energy Technology Data Exchange (ETDEWEB)

    Salceda, V. M. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: vmss@nuclear.inin.mx

    2008-07-01

    In order to obtain data about the possible changes and/or damages that could cause the operation of the reactors of the nuclear power plant of Laguna Verde to the populations of drosophila Melanogaster that lives in the zone, one carried out one series of biannual collections (summer and winter) during the years 1991-1992 and 1996-1998 to obtain individuals of this species and to subject them to a battery of tests. The flies of this species that it was possible to capture were transported to the Biology Laboratory of the National Institute of Nuclear Research, where they were put under in individual form a series of you cross they allowed that us in the third generation to detect the presence of deletereo genes that following their viability were catalogued like normal, lethal or less lethal according to the methodology of Wallace. This way a total of 933 second chromosomes was analyzed to leave of them the relative frequencies were calculated of each one of the categories, for each sample station. The result of the applied statistical test indicates us that not significant difference exists among the populations and that the differences of having them must only to the environment changes something that usually happen in all the population. For what we can point out that the presence of the reactors does not seem to influence negatively in the behavior of the population that lives in the zone. (Author)

  6. Temporary storage in dry of the spent nuclear fuel in the Nuclear Power Plant of Laguna Verde; Almacenamiento temporal en seco del combustible nuclear gastado en la Central Nuclear Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez M, N.; Vargas A, A., E-mail: natividad.hernandez@cfe.gob.mx [Comision Federal de Electricidad, Gerencia de Centrales Nucleoelectricas, Carretera Veracruz-Medellin Km. 7.5, 94270 Dos Bocas, Veracruz (Mexico)

    2013-10-15

    To guarantee the continuity in the operation of the two nuclear reactors of the nuclear power plant of Laguna Verde (NPP-L V) is an activity of high priority of the Comision Federal de Electricidad (CFE) in Mexico. At the present time, the CFE is working in the storage project in dry of the spent fuel with the purpose of to liberate space of the pools and to have the enlarged capacity of storage of the spent fuel that is discharged of the reactors. This work presents the storage option in dry of the spent fuel, considering that the original capacity of the spent fuel pools of the NPP-L V was of 1242 spaces each one and that in 1991, through a modification of the original design, the storage capacity was increased to 3177 spaces by pool. At present, the cells occupied by unit are of 2165 (68%) for the Unit-I and 1839 (58%) for the Unit-2, however, in 2017 and 2022 the capacity to discharge the complete core will be limited by what is required of a retirement option of spent fuel assemblies to liberate spaces. (author)

  7. Feasibility analysis in the expansion proposal of the nuclear power plant Laguna Verde: application of real options, binomial model; Analisis de viabilidad en la propuesta de expansion de la central nucleoelectrica Laguna Verde: aplicacion de opciones reales, modelo binomial

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez I, S.; Ortiz C, E.; Chavez M, C., E-mail: lunitza@gmail.com [UNAM, Facultad de Ingenieria, Circuito Interior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2011-11-15

    At the present time, is an unquestionable fact that the nuclear electrical energy is a topic of vital importance, no more because eliminates the dependence of the hydrocarbons and is friendly with the environment, but because is also a sure and reliable energy source, and represents a viable alternative before the claims in the growing demand of electricity in Mexico. Before this panorama, was intended several scenarios to elevate the capacity of electric generation of nuclear origin with a variable participation. One of the contemplated scenarios is represented by the expansion project of the nuclear power plant Laguna Verde through the addition of a third reactor that serves as detonator of an integral program that proposes the installation of more nuclear reactors in the country. Before this possible scenario, the Federal Commission of Electricity like responsible organism of supplying energy to the population should have tools that offer it the flexibility to be adapted to the possible changes that will be presented along the project and also gives a value to the risk to future. The methodology denominated Real Options, Binomial model was proposed as an evaluation tool that allows to quantify the value of the expansion proposal, demonstrating the feasibility of the project through a periodic visualization of their evolution, all with the objective of supplying a financial analysis that serves as base and justification before the evident apogee of the nuclear energy that will be presented in future years. (Author)

  8. Development of a methodology for the economical analysis of fuel cycles, application to the Laguna Verde central; Desarrollo de una metodologia para el analisis economico de ciclos de combustible, aplicacion a la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Malfavon, S.M.; Trejo, M.G.; Hernandez, H. [FI-UNAM, 04500 Mexico D.F. (Mexico); Francois, J.L.; Ortega, R.F. [FI-UNAM, Paseo Cuauhnahuac 8532, Jiutepec, Morelos (Mexico)

    2003-07-01

    In this work a methodology developed to carry out the economical analysis of the fuel cycle of a nuclear reactor is presented. The methodology was applied to the Laguna Verde Nuclear Power Station (CNLV). The design of the reload scenarios of the CNLV are made with the Core Master Presto code (CM-Presto), three-dimensional simulator of the reactor core, the launched data by this, as well as the information of the Energy use plan (PUE), it allowed us to obtain reliable results through the fitness of an algorithm of economic calculation that considers all the components of the fuel cycle to present worth. With the application of the methodology it was obtained the generated energy, as well as their respective cost of each sub lot type of assemblies by operation cycle, from the start-up of the CNLV until September 13, 2002. Using the present worth method its were moved all the values at November 5, 1988, date of operation beginning. To the final of the analysis an even cost of 6.188 mills/kWh was obtained for those first 9 cycles of the Unit 1 of the CNLV, being observed that the costs of those first 3 operation cycles are the more elevated. Considering only the values starting from the cycle 4, the levelled cost turns out to be of 5.96 mills/kWh. It was also obtained the cost by fuel lot to evaluate the performance of assemble with the same physical composition. (Author)

  9. Generation of the ECP database (ECP02.DAT) at the beginning of the cycle 1 of the Unit 1 of Laguna Verde

    International Nuclear Information System (INIS)

    Perusquia C, R.

    1992-10-01

    In order to carrying out a comparison among the results provided for the Program of Estimate of the ECP Critical Position and the Shutdown/Startup produced in the Cycle 1 of the Unit 1 of Laguna Verde, it was generated the base of the ECP program, following the outlines settled down in the Procedure 'Generation of ECP Database for Laguna Verde' (IT.SN/DFR 074). Next the data sheets filled when being generated the ECP02.DAT database at the beginning of the cycle are provided. In the IT.SN/DFR 079 report 'Adjustment and Preliminary Evaluation of the Predictions of Criticity of the ECP Program with Reported Data of Cycle 1 of the Unit 1 of Laguna Verde, the results of the comparison among the estimates of the ECP program using the ECP02.DAT with the real data of the Cycle 1 of the Unit 1 of Laguna Verde are presented. (Author)

  10. Generation of the ECP database (ECP01.DAT) of the cycle 1 of the Unit 1 of Laguna Verde with burnt of 1377 MWD/MT

    International Nuclear Information System (INIS)

    Perusquia C, R.

    1992-10-01

    In order to carrying out a comparison among the results provided by the Program of Estimate of the ECP Critical Position and the Shutdown/Startup produced in the Cycle 1 of the Unit 1 of Laguna Verde, it was generated the base of the ECP program, following the outlines settled down in the Procedure 'Generation of ECP Database for Laguna Verde' (IT.SN/DFR-074). Next the data sheets filled when being generated the ECP01.DAT database with a burnt of 1377 MWD/MT are provided. In the report IT.SN/DFR-079 'Adjustment and Preliminary Evaluation of the Predictions of Criticity of the ECP Program with Reported Data of the Cycle 1 of the Unit 1 of Laguna Verde', the results of the comparison among those estimates of the ECP program using the ECP01.DAT database with the real data of the Cycle 1 of the Unit 1 of Laguna Verde are presented. (Author)

  11. Participation of the ININ in the activities of radioactive waste management of the Laguna Verde Central

    International Nuclear Information System (INIS)

    Medrano L, M.; Rodriguez C, C.; Linares R, D.; Ramirez G, R.; Zarate M, N.

    2006-01-01

    From the beginning of the operation of the Laguna Verde Central (CLV) the National Institute of Nuclear Research (ININ) has come supporting the CLV in the activities of administration of the humid and dry radioactive waste generated by the operation of the two units of the CLV, from the elaboration of procedures to the temporary storage in site, the implementation of a program of minimization and segregation of dry solid wastes, until the classification of the lots of humid waste and bulk dry wastes. In this work the description of the management activities of radioactive wastes carried out by the ININ in the facilities of the CLV to the date is presented, as well as some actions that they are had drifted in the future near, among those that it stands out the determination of the total alpha activity in humid samples by means of scintillation analysis. (Author)

  12. Estimating of seismic return periods in Laguna Verde Nuclear Power Plant

    International Nuclear Information System (INIS)

    Flores R, J.H.

    1993-01-01

    The study of seismic risk in the site of Laguna Verde Nuclear Power Plant and surroundings was made considering the different periods of seismic return and the probability of occurrence in distinct time intervals (50, 75, 100, 125, 150 years) starting with the distribution of first type of extreme values of Gumbel (G1), the value used for the assessment of lifetime of lump was 50 years, and the rest of the periods are used to evaluate temporary nuclear cemeteries, it is to say for reducing the radioactivity of burned fuel assemblies. The seismic data belongs to the seismicity catalog (1920-1982) elaborated around the site, which average magnitude was 5 in the Richter Scale and are considered as shallow and are located in the Continental crust of North American shelf, and are induced by the pressure of the cocos shelf, being 36 % of the seismic movements of intermediate value and two seismic movements of deep value. (Author)

  13. Feasibility analysis in the expansion proposal of the nuclear power plant Laguna Verde: application of real options, binomial model

    International Nuclear Information System (INIS)

    Hernandez I, S.; Ortiz C, E.; Chavez M, C.

    2011-11-01

    At the present time, is an unquestionable fact that the nuclear electrical energy is a topic of vital importance, no more because eliminates the dependence of the hydrocarbons and is friendly with the environment, but because is also a sure and reliable energy source, and represents a viable alternative before the claims in the growing demand of electricity in Mexico. Before this panorama, was intended several scenarios to elevate the capacity of electric generation of nuclear origin with a variable participation. One of the contemplated scenarios is represented by the expansion project of the nuclear power plant Laguna Verde through the addition of a third reactor that serves as detonator of an integral program that proposes the installation of more nuclear reactors in the country. Before this possible scenario, the Federal Commission of Electricity like responsible organism of supplying energy to the population should have tools that offer it the flexibility to be adapted to the possible changes that will be presented along the project and also gives a value to the risk to future. The methodology denominated Real Options, Binomial model was proposed as an evaluation tool that allows to quantify the value of the expansion proposal, demonstrating the feasibility of the project through a periodic visualization of their evolution, all with the objective of supplying a financial analysis that serves as base and justification before the evident apogee of the nuclear energy that will be presented in future years. (Author)

  14. Development of a methodology for the economical analysis of fuel cycles, application to the Laguna Verde central

    International Nuclear Information System (INIS)

    Malfavon, S.M.; Trejo, M.G.; Hernandez, H.; Francois, J.L.; Ortega, R.F.

    2003-01-01

    In this work a methodology developed to carry out the economical analysis of the fuel cycle of a nuclear reactor is presented. The methodology was applied to the Laguna Verde Nuclear Power Station (CNLV). The design of the reload scenarios of the CNLV are made with the Core Master Presto code (CM-Presto), three-dimensional simulator of the reactor core, the launched data by this, as well as the information of the Energy use plan (PUE), it allowed us to obtain reliable results through the fitness of an algorithm of economic calculation that considers all the components of the fuel cycle to present worth. With the application of the methodology it was obtained the generated energy, as well as their respective cost of each sub lot type of assemblies by operation cycle, from the start-up of the CNLV until September 13, 2002. Using the present worth method its were moved all the values at November 5, 1988, date of operation beginning. To the final of the analysis an even cost of 6.188 mills/kWh was obtained for those first 9 cycles of the Unit 1 of the CNLV, being observed that the costs of those first 3 operation cycles are the more elevated. Considering only the values starting from the cycle 4, the levelled cost turns out to be of 5.96 mills/kWh. It was also obtained the cost by fuel lot to evaluate the performance of assemble with the same physical composition. (Author)

  15. Impact of flow induced vibration acoustic loads on the design of the Laguna Verde Unit 2 steam dryer

    International Nuclear Information System (INIS)

    Forsyth, D. R.; Wellstein, L. F.; Theuret, R. C.; Han, Y.; Rajakumar, C.; Amador C, C.; Sosa F, W.

    2015-09-01

    Industry experience with Boiling Water Reactors (BWRs) has shown that increasing the steam flow through the main steam lines (MSLs) to implement an extended power up rate (EPU) may lead to amplified acoustic loads on the steam dryer, which may negatively affect the structural integrity of the component. The source of these acoustic loads has been found to be acoustic resonance of the side branches on the MSLs, specifically, coupling of the vortex shedding frequency and natural acoustic frequency of safety relief valves (SRVs). The resonance that results from this coupling can contribute significant acoustic energy into the MSL system, which may propagate upstream into the reactor pressure vessel steam dome and drive structural vibration of steam dryer components. This can lead to high-cycle fatigue issues. Lock-in between the vortex shedding frequency and SRV natural frequency, as well as the ability for acoustic energy to propagate into the MSL system, are a function of many things, including the plant operating conditions, geometry of the MSL/SRV junction, and placement of SRVs with respect to each other on the MSLs. Comision Federal de Electricidad and Westinghouse designed, fabricated, and installed acoustic side branches (ASBs) on the MSLs which effectively act in the system as an energy absorber, where the acoustic standing wave generated in the side-branch is absorbed and dissipated inside the ASB. These ASBs have been very successful in reducing the amount of acoustic energy which propagates into the steam dome. In addition, modifications to the Laguna Verde Nuclear Power Plant Unit 2 steam dryer have been completed to reduce the stress levels in critical locations in the dryer. The objective of this paper is to describe the acoustic side branch concept and the design iterative processes that were undertaken at Laguna Verde Unit 2 to achieve a steam dryer design that meets the guidelines of the American Society of Mechanical Engineers, Boiler and Pressure

  16. Impact of flow induced vibration acoustic loads on the design of the Laguna Verde Unit 2 steam dryer

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, D. R.; Wellstein, L. F.; Theuret, R. C.; Han, Y.; Rajakumar, C. [Westinghouse Electric Company LLC, Cranberry Township, PA 16066 (United States); Amador C, C.; Sosa F, W., E-mail: forsytdr@westinghouse.com [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Km 42.5 Carretera Cardel-Nautla, 91680 Alto Lucero, Veracruz (Mexico)

    2015-09-15

    Industry experience with Boiling Water Reactors (BWRs) has shown that increasing the steam flow through the main steam lines (MSLs) to implement an extended power up rate (EPU) may lead to amplified acoustic loads on the steam dryer, which may negatively affect the structural integrity of the component. The source of these acoustic loads has been found to be acoustic resonance of the side branches on the MSLs, specifically, coupling of the vortex shedding frequency and natural acoustic frequency of safety relief valves (SRVs). The resonance that results from this coupling can contribute significant acoustic energy into the MSL system, which may propagate upstream into the reactor pressure vessel steam dome and drive structural vibration of steam dryer components. This can lead to high-cycle fatigue issues. Lock-in between the vortex shedding frequency and SRV natural frequency, as well as the ability for acoustic energy to propagate into the MSL system, are a function of many things, including the plant operating conditions, geometry of the MSL/SRV junction, and placement of SRVs with respect to each other on the MSLs. Comision Federal de Electricidad and Westinghouse designed, fabricated, and installed acoustic side branches (ASBs) on the MSLs which effectively act in the system as an energy absorber, where the acoustic standing wave generated in the side-branch is absorbed and dissipated inside the ASB. These ASBs have been very successful in reducing the amount of acoustic energy which propagates into the steam dome. In addition, modifications to the Laguna Verde Nuclear Power Plant Unit 2 steam dryer have been completed to reduce the stress levels in critical locations in the dryer. The objective of this paper is to describe the acoustic side branch concept and the design iterative processes that were undertaken at Laguna Verde Unit 2 to achieve a steam dryer design that meets the guidelines of the American Society of Mechanical Engineers, Boiler and Pressure

  17. Preliminary analysis of an hydrogen generator system based on nuclear energy in the Laguna Verde site; Analisis preliminar de un sistema generador de hidrogeno basado en energia nuclear en el sitio de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Flores y Flores, A [FI-UNAM, 04500 Mexico D.F. (Mexico); Francois L, J L [FI-UNAM, Jiutepec, Morelos (Mexico)

    2003-07-01

    The shortage of fossil fuels in the next future, as well as the growing one demand of energetics and the high cost of the production of alternating fuels, it forces us to take advantage of to the maximum the fossil fuel with the one which we count and to look for the form of producing alternating fuels at a low cost and better even if these supply sources are reliable and non pollutants. It is intended a solution to the shortage of fuel; to use the thermal energy liberated of some appropriate nuclear reactor to be able to obtain a fuel but clean and relatively cheap as it is the hydrogen. In the first place the methods were looked for to produce hydrogen using thermal energy, later it was analyzed the temperature liberated by the existent nuclear reactors as well as the advanced designs, according to this liberated temperature settled down that the methods but feasible to produce hydrogen its were the one of reformed with water stream of the natural gas (methane) and the other one of the S-I thermochemical cycle, and the nuclear reactors that give the thermal energy for this production they are those of gas of high temperature. Once established the processes and the appropriate reactors, it was analyzed the site of Laguna Verde, with relationship to the free space to be able to place the reactor and the plant producer of hydrogen, as well as the direction in which blow the dominant winds and the near towns to the place, it was carried out an analysis of some explosion of tanks that could store hydrogen and the damage that its could to cause depending from the distance to which its were of the fire. Finally it was carried out an evaluation of capital and of operation costs for those two methods of hydrogen production. (Author)

  18. Evaluation of the integrity and duration of the Laguna Verde nuclear power plant life- Plant Life Management program (PLIM). TC MEX 04/53 Technical Cooperation Project; Evaluacion de la integridad y extension de vida de la planta de potencia nuclear Laguna Verde- Programa de manejo de vida de planta (PLIM). Proyecto de cooperacion tecnica TC MEX 04/53

    Energy Technology Data Exchange (ETDEWEB)

    Arganis J, C.R.; Diaz S, A.; Aguilar T, J.A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2006-07-01

    As part of the IAEA TC MEX 04/53 Project 'Evaluation of the integrity and extension of life of the Laguna Verde nuclear power plant Handling Program of plant' whose objective is the one of beginning the actions to apply the methodology of Handling of plant life in the Unit 1 of the Laguna Verde Nucleo electric Central for to obtain the Renovation of License in 2020 the ININ, through the Department of Synthesis and Characterization of materials has carried out more of 20 analysis of susceptibility to the intergranular cracking for corrosion under effort in interns so much of the reactor of the unit 1 like of the unit 2 documenting the current state of components based on the type or types of materials that conform them, to it thermomechanical history, operational and of production, as well as of the particularities associated to its use and operation. For the application of the methodology of life handling of plant 5 structure systems or pilot components were selected, to carry out the programs of handling of the aging and handling of plant life: The encircling of the reactor core (Core Shroud), the reactor pressure vessel (Reactor Pressure Vessel), the primary container (Primary Containment), the recirculation system of feeding water (Reactor Feed Water) and cables. (Author)

  19. Turbine model for the Laguna Verde nucleo electric central based in the RELAP code

    International Nuclear Information System (INIS)

    Cortes M, F.S.; Ramos P, J.C.; Salazar S, E.; Chavez M, C.

    2003-01-01

    The Nuclear Power stations as Laguna Verde occupy at the present time a place every time but important as non pollutant alternative, economic and trusty to generate electricity. It is for it that the Group of Nuclear Engineering of the Engineering Faculty (GrlNFI) of the National Autonomous University of Mexico (UNAM) it develops investigation projects applied to Nuclear Centrals. One of the projects in process is the development of a Classroom simulator, which it can configures to consent to diverse models of nuclear systems with training purposes in normal operation, or, to consent to specialized nuclear codes for the analysis of transitory events and have a severe accident. This work describes the development, implementation and it proves of a simplified model of the Main turbine to be integrated to the group of models of the Classroom simulator. It is part of the current effort of GrlNFI guided to obtain a representation of all the dynamic models necessary to simulate the Plant Balance of the Laguna Verde Central. It is included the development of the unfolding graphic which represent the modeling of the Main turbine, and of the control interface that allows the user to manipulate in simple way, direct and interactive this device during the training or the analysis. With this work it is wanted to contribute to the training of new technicians and to support the operation personnel of the Centrals. Also, the developed infrastructure is guided to contribute in the design and analysis of new Nuclear Power stations with the contribution of new computational tools for the visualization, simulation and process control. (Author)

  20. Stress corrosion evaluation on stainless steel 304 pipes in Laguna Verde Nuclear Power Plant

    International Nuclear Information System (INIS)

    Arganis J, C.R.

    1996-01-01

    Inside the frame of the project IAEA/MEX-41044 'Stress corrosion as a starting event of accidents in nuclear plants', and of the institutional project IA-252 under the same name, it was required from the Laguna Verde Nuclear Plant, material equivalent to the one employed in the piping of the primary recycling system. Laguna Verde Nuclear Plant granted two tracks of tubes, that could be used to substitute the ones that are in operation, as is the tube SA-358TP304 CL-QC with transversal welding, designated as ER-316-LQA. According to the report entitles 'Revision of the operational experience related to corrosion in the nuclear plants' it was found that the stress corrosion is the principal mechanism of corrosion present in the nuclear plants. Previous records indicate that sensitized stainless steels are resistant to stress corrosion in testings of constant loading in sea water (3.5% of chlorides approximately) to 80 Centigrade and to 80% of the limit of conveyance and that a solution of 22% of NaCl to 90 Centigrade, produces cracking due to stress corrosion in highly sensitized steels, in tests of speed of slow extension (SSRT), to a speed of 1x10 -6 s -1 . Daniels reports that there is a direct relation between the speed limit of detection of the SSRT test and the concentration of chlorides, for stainless steels tested to 100 Centigrade. The minimum detection speed of susceptibility to stress corrosion for solution to 20% of NaCl, is of 1x10 -7 s -1 . Taking into account these considerations, the employment of a solution with 22% of NaCl to 90 Centigrade to a speed of 1x10 -6 s -1 seems a good choice for the evaluation of stainless steel. (Author)

  1. The Laguna Verde Central by it results in maintenance and operation consolidates it position of world class enterprise; La central Laguna Verde por sus resultados en mantenimiento y operacion consolida su posicion de empresa de clase mundial

    Energy Technology Data Exchange (ETDEWEB)

    Rivera C, A. [CFE, Central Laguna Verde, Km. 42.5 Carretera Cardel- Nautla, Veracruz (Mexico)

    2008-07-01

    This work has the objective of showing the results of the Laguna VerdeCentral in the maintenance and the operation that in the short term the generation of electricity in Mexico by nuclear means is a viable option, in virtue of their positioning like Company of World Class, when winning March 25, 2008 the National Prize of Quality with the more high qualification in the history of this prize, same that allows us to be very optimistic in increasing the possibility to that the Nuclear Industry in Mexico grows. The focus of the comparative graphs, with official data of the Comision Federal de Electricidad (CFE), it is so that it is observed that the Laguna Verde Central is above those the other types of generation like they are the Coal power stations, Thermoelectric, Hydroelectric, likewise they can see that we are for up of the Independent Producers of Energy. The information of the electric power generation is presented by reactors nuclear at world level that is growing, in having 31 Generating Units in the construction process that favors the decisions making in the Government federal, likewise contributed data of the increment projected for 2016 in the country of 380,102 GWh that equivalent to 63% of growth, where it exists without place to doubts a good opportunity for the nucleoelectricity. The Investment Works Program of Public Sector (POISE), it shows the information that 6,178 Mwe will be installed settled of a Non-defined Technology in Mexico, information that specifies the opportunity to be a viable option, because the one Plant Factor, the Production of Electric power, and the Variable Cost of Production, the energy generation by nuclear means is the more competitiveness. Finally this work stood out the effort that communitary works are developed to benefit to the society and the environment to be one Viable option not only for their high performance, or competitive for those more low costs, but also to improve the public opinion with the sustainable

  2. Seismic qualification tests of fans of the NPP of Laguna Verde U-1 and U-2; Pruebas de calificacion sismica de ventiladores de la Central Laguna Verde U1 and U2

    Energy Technology Data Exchange (ETDEWEB)

    Jarvio C, G.; Garcia H, E. E.; Arguelles F, R.; Vela H, A. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Naranjo U, J. L., E-mail: gilberto.jarvio@inin.gob.mx [Comision Federal de Electricidad, Gerencia de Centrales Nucleoelectricas, Subgerencia de Ingenieria, Carretera Veracruz-Medellin Km 7.5, Dos Bocas, Veracruz (Mexico)

    2013-10-15

    This work presents the results of the seismic qualification tests applied to the fans that will be installed in the control panels of the three divisions of the diesel generators of the nuclear power plant (NPP) of Laguna Verde, Unit-1 and Unit-2. This seismic qualification process of the fans was carried out using two specimens that were tested in the seismic table (vibrating) of the Engineering Institute of Universidad Nacional Autonoma de Mexico (UNAM), in accordance with the requirements of the standard IEEE 344-1975, to satisfy the established requirements of seismic qualification in the technical specifications and normative documents required by the nuclear standards, in order to demonstrate its application in the diesel generators Divisions I, II and III of the NPP. The seismic qualification tests were developed on specimens that were retired of the NPP of Laguna Verde recently with a service life of 7.75 years. (Author)

  3. Analysis of internal events for the Unit 1 of the Laguna Verde Nuclear Power Station. Appendixes; Analisis de eventos internos para la Unidad 1 de la Central Nucleoelectrica de Laguna Verde. Apendices

    Energy Technology Data Exchange (ETDEWEB)

    Huerta B, A; Lopez M, R [Comision Nacional de Seguridad Nuclear y Salvaguardias, 03000 Mexico D.F. (Mexico)

    1995-07-01

    This volume contains the appendices for the accident sequences analysis for those internally initiated events for Laguna Verde Unit 1, Nuclear Power Plant. The appendix A presents the comments raised by the Sandia National Laboratories technical staff as a result of the review of the Internal Event Analysis for Laguna Verde Unit 1 Nuclear Power Plant. This review was performed during a joint Sandia/CNSNS multi-day meeting by the end 1992. Also included is a brief evaluation on the applicability of these comments to the present study. The appendix B presents the fault tree models printed for each of the systems included and.analyzed in the Internal Event Analysis for LVNPP. The appendice C presents the outputs of the TEMAC code, used for the cuantification of the dominant accident sequences as well as for the final core damage evaluation. (Author)

  4. Validation of a new software version for monitoring of the core of the Unit 2 of the Laguna Verde power plant with ARTS; Validacion de una nueva version del software para monitoreo del nucleo de la Unidad 2 de la Central Laguna Verde con ARTS

    Energy Technology Data Exchange (ETDEWEB)

    Calleros, G.; Riestra, M.; Ibanez, C.; Lopez, X.; Vargas, A.; Mendez, A.; Gomez, R. [CFE, Central Nucleoelectrica de Laguna Verde, Alto Lucero, Veracruz (Mexico)]. e-mail: gcm9acpp@cfe.gob.mx

    2005-07-01

    In this work it is intended a methodology to validate a new version of the software used for monitoring the reactor core, which requires of the evaluation of the thermal limits settled down in the Operation Technical Specifications, for the Unit 2 of Laguna Verde with ARTS (improvements to the APRMs, Rod Block Monitor and Technical specifications). According to the proposed methodology, those are shown differences found in the thermal limits determined with the new versions and previous of the core monitoring software. Author)

  5. Optimization of reloading Laguna Verde Central U1/U2, Federal Electricity Commission; Optimizacion de recargas Central Laguna Verde U1/U2, Comision Federal de Electricidad

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa G, J.M. [Central Nucleoelectrica Laguna Verde, Carretera Cardel-Nautla Km. 45.5, Municipio de Alto Lucero, Veracruz (Mexico)

    2006-07-01

    The Laguna Verde Central from the beginning of the commercial operation settled down as maximum priority 'the total safety in its operation' taking in consideration the so much experience of the good operation and of multiple recharges made in a sure and reliable way, and without separate us of the safety mystic of the CLV, but looking for to be better every day a new challenge it settled down 'to compare us with the best plants in the world' and certainly to work to classify us like one of them. For this we established a 4.0 year old plan (2003/2006) for the effectiveness all the processes in the power station that allowed us to measure our acting with the same parameters that settle down at international level (nuclear safety, industrial safety, radiological safety, capacity factor, readiness factor, cleaning of the power station, attachment to procedures, attention to the detail and certainly to be competitive in the economic aspect, summing up means to be good in all the aspects). All the above mentioned would allow us to qualify us as level 1 of WANO (world proprietors association of nuclear centrals) at the end of the year 2006 and to pass to be part of this select group. After analyzing the acting record of the power station, evaluating our technical and economic capacity, the location of the installation besides revising the international experiences was defined that one of the concepts that impact considerably so much to the capacity factors and availability besides the dose and production cost is the duration of the recharge periods, for this reason the present work is elaborated. (Author)

  6. Planning of activities in the Laguna Verde Central planning at 12 weeks; Planeacion de Actividades en la Central Laguna Verde planeacion a doce semanas

    Energy Technology Data Exchange (ETDEWEB)

    Chimalpopoca, C. [Comision Federal de Electricidad, Central Laguna Verde, Subgerencia General de Operacion y Planeacion, Veracruz (Mexico)]. e-mail: carlos.chimalpopoca@cfe.gob.mx

    2007-07-01

    The universe of works that are carried out in a nuclear facility to maintain effective the structures, systems and components require of a continuous analysis, in the order of the maintenance frequencies that can be of the preventive, predictive or corrective type. Each component is associated to reserve parts, readiness of systems, in fulfillment to the operation technical specifications, to the environment of the one work; each component requires of a planning level, where it is distinguished with clarity when they are executed, in the operation stage, stop or recharge. This work has as end to show like the activities are planned during the operation, using planning methods to twelve weeks, where the reach of the task is conceptualized, operative requirements, of reserve parts, of the work environment analysis, of those radiological conditions, of the authorizations for their execution, the same execution and the evaluation post work like a technique to maintain in continuous improvement the tasks of the maintenance of the Units of the Power station. A motor valve to be worked in its internals requires access to the work point, it requires bill of the system, electric disconnection, maneuvers to disassemble actuators and retirement of thermal isolation if it applies, reserve parts of the caps joints, control mechanisms, personal, tools, radiological control. The success of the continuous operation of a power station is in the planning quality, the attention of each one of the details to assure that the components, structures and components stay effective to make their function when they are demanded. The planning task requires of experience and knowledge of each some of the components, the task of planning of activities and its execution is multidisciplinary This work has that purpose, to show the planning tools in the Laguna Verde Nuclear Power station, under the concept of twelve weeks. (Author)

  7. Internal event analysis of Laguna Verde Unit 1 Nuclear Power Plant. System Analysis; Analisis de Eventos Internos para la Unidad 1 de la Central Nucleoelectrica de Laguna Verde. Analisis de sistemas

    Energy Technology Data Exchange (ETDEWEB)

    Huerta B, A; Aguilar T, O; Nunez C, A; Lopez M, R [Comision Nacional de Seguridad Nuclear y Salvaguardias, 03000 Mexico D.F. (Mexico)

    1993-07-01

    The Level 1 results of Laguna Verde Nuclear Power Plant PRA are presented in the {sup I}nternal Event Analysis of Laguna Verde Unit 1 Nuclear Power Plant{sup ,} CNSNS-TR-004, in five volumes. The reports are organized as follows: CNSNS-TR-004 Volume 1: Introduction and Methodology. CNSNS-TR-004 Volume 2: Initiating Event and Accident Sequences. CNSNS-TR-004 Volume 3: System Analysis. CNSNS-TR-004 Volume 4: Accident Sequence Quantification and Results. CNSNS-TR-004 Volume 5: Appendices A, B and C. This volume presents the results of the system analysis for the Laguna Verde Unit 1 Nuclear Power Plant. The system analysis involved the development of logical models for all the systems included in the accident sequence event tree headings, and for all the support systems required to operate the front line systems. For the Internal Event analysis for Laguna Verde, 16 front line systems and 5 support systems were included. Detailed fault trees were developed for most of the important systems. Simplified fault trees focusing on major faults were constructed for those systems that can be adequately represent,ed using this kind of modeling. For those systems where fault tree models were not constructed, actual data were used to represent the dominant failures of the systems. The main failures included in the fault trees are hardware failures, test and maintenance unavailabilities, common cause failures, and human errors. The SETS and TEMAC codes were used to perform the qualitative and quantitative fault tree analyses. (Author)

  8. Super compacting of drums with dry solid radioactive waste in the nuclear power plant of Laguna Verde;Super compactacion de bidones con desecho radiactivo solido seco en la central nucleo electrica Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez G, R.; Lara H, M. A.; Cabrera Ll, M.; Verdalet de la Torre, O., E-mail: marco.lara@cfe.gob.m [Comision Federal de Electricidad, Central Nucleoelectrica de Laguna Verde, Carretera Nautla-Cardel Km. 42.5, Alto Lucero, Veracruz (Mexico)

    2009-10-15

    The nuclear power plant of Laguna Verde located in the Gulf of Mexico, completes in this 2009, nineteen years to produce by nuclear means 4.78% of the electric power that Mexico requires daily. During this time, the Unit 1 has generated more of 88.85 million mega watt-hour and the Unit 2 more of 69.48 million mega watt-hour with an availability average of 83.55%. Derived of their operation cycles, the nuclear power plant has generated (as any other installation of its type) radioactive wastes of low activity that at the moment are temporarily stored in the site. Due to the life cycle of the nuclear power plant, actually has become necessary to begin a project series focused to continue guaranteeing the storage of these wastes, guarantee that is a license requirement for the operation of this nuclear installation before the National Commission of Nuclear Security and Safeguards. The Federal Commission of Electricity beginning a project that allows continue guaranteeing space of sufficient storage for the wastes that the nuclear power plant of Laguna Verde could generate for the rest of its useful life, this project consisted on a process of physical volume reduction of dry solid radioactive wastes denominated super compacting, it has made possible to reduce the volume that these wastes occupy in the temporary storage noted Dry Solid Radioactive Wastes Deposit located inside the site that occupies the nuclear power plant of Laguna Verde. This work presents the super compacting results, as well as a description of the realization of this task until concluding with the super compacting of 5,854 drums with dry solid radioactive waste of low activity. We will enunciate which were the radiological controls that the Department of Radiological Protection of the nuclear power plant of Laguna Verde applied to this work that was realized for first time in Mexico and the nuclear power plant. (Author)

  9. The Laguna Verde Central by it results in maintenance and operation consolidates it position of world class enterprise

    International Nuclear Information System (INIS)

    Rivera C, A.

    2008-01-01

    This work has the objective of showing the results of the Laguna VerdeCentral in the maintenance and the operation that in the short term the generation of electricity in Mexico by nuclear means is a viable option, in virtue of their positioning like Company of World Class, when winning March 25, 2008 the National Prize of Quality with the more high qualification in the history of this prize, same that allows us to be very optimistic in increasing the possibility to that the Nuclear Industry in Mexico grows. The focus of the comparative graphs, with official data of the Comision Federal de Electricidad (CFE), it is so that it is observed that the Laguna Verde Central is above those the other types of generation like they are the Coal power stations, Thermoelectric, Hydroelectric, likewise they can see that we are for up of the Independent Producers of Energy. The information of the electric power generation is presented by reactors nuclear at world level that is growing, in having 31 Generating Units in the construction process that favors the decisions making in the Government federal, likewise contributed data of the increment projected for 2016 in the country of 380,102 GWh that equivalent to 63% of growth, where it exists without place to doubts a good opportunity for the nucleoelectricity. The Investment Works Program of Public Sector (POISE), it shows the information that 6,178 Mwe will be installed settled of a Non-defined Technology in Mexico, information that specifies the opportunity to be a viable option, because the one Plant Factor, the Production of Electric power, and the Variable Cost of Production, the energy generation by nuclear means is the more competitiveness. Finally this work stood out the effort that communitary works are developed to benefit to the society and the environment to be one Viable option not only for their high performance, or competitive for those more low costs, but also to improve the public opinion with the sustainable

  10. Application of new control technology during the maintenance of equipment in the Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Ojeda R, M. A.

    2008-01-01

    In the nuclear power plant of Laguna Verde, in normal operation and recharges are carried out activities of preventive maintenance and corrective to different equipment, due to the one displacement of radioactive materials from the vessel of the reactor until the one system of vapor, different radiation levels are generated (from low until very high) in the circuits of vapor and water, the particles can be incrusted on those interior surfaces of the pipes and equipment, creating this way a potential risk of contamination and exhibition during the maintenance of equipment. To help to optimize the dose to the personnel the use of new technology the has been implemented which besides contributing an absolute control of the work, it offers bigger comfort to the one worker during the development of their work, also contributing a supervision more effective of the same one. Using the captured and processed information of the work developed you can use for the personnel's capacitation and feedback of the work for the continuous improvement of the same one. During a reduction of programmed power and normal operation are carried out maintenance correctives and specific works to preserve the readiness and ability of the equipment and with this to maintain the security of the nuclear power plant. The development of the theme it is showing the advances and commitments of personnel to take to excellence to the nuclear power plant of Laguna Verde showing to the obtained results of the dose and benefits of 2 works carried out in the nuclear power plant where tools ALARA were applied as well as the use of the new technology (Video Equipment of Tele dosimetry and Audio 'VETA') in works carried out in the building of purification level 10.15, change and cuts of filter of the prefilters of system G16, as well as,the retirement and transfer for its decay of High Integrity Container (HIC) of the building of purification level -0.55 to the Temporary Warehouse in Site. Works of high

  11. Technological evaluation for the extension of the operation license to the nuclear power plant of Laguna Verde

    International Nuclear Information System (INIS)

    Arganis J, C. R.; Medina A, A. L.

    2010-01-01

    At the present time one of the tendencies in the nuclear industry is the renovation of operation licenses of the nuclear power plants, with the purpose of prolonging their operation 20 years more than the time settled down in their original license, which is of 30 years for the case of the nuclear power plant of Laguna Verde. This allows the electric power generation for a major period of time and to a relatively low price, giving this way a bigger competitiveness to the power stations of nuclear power. However, to request the license extension of the nuclear power plant requires to get ready the documentation and necessary studies for: to maintain a high level of security, to optimize the operation, maintenance and service life of the structures, systems and components, to maintain an acceptable level of performance, to maximize the recovery of the investment about the service of the nuclear power plant and to preserve the sure conditions for a major operation period at the license time. This paper describes the studies conducted by the Materials Technology Department of the Instituto Nacional de Investigaciones Nucleares (ININ) to substantiate the required documentation for obtaining the extension of operating license of the nuclear power plant. These studies are focused mainly in the reactor pressure vessels of both units, as well as in the deposit of noble metals and the influence of the sludges (crud s) in this deposit. (Author)

  12. Estimation of seismic return periods in the Laguna Verde nuclear plant; Estimacion de periodos de retorno sismico en la PNLV

    Energy Technology Data Exchange (ETDEWEB)

    Flores R, J.H

    1992-01-15

    The study of seismic risk in the area of the Laguna Verde Nucleo electric plant (PNLV) and its surroundings, one carries out estimating the different return periods and the occurrence probability in different intervals of time (5, 75, 100, 125, 150 years starting from the distribution of first type of Gumbel (G1) of extreme values (Burton, 1986), the value that was used to evaluate the useful life of the PNLV was of 50 years, the other periods will be occupy to evaluate 'temporal' nuclear cemeteries, that is to say for diminish the radioactive activity of the fuel assemblies already burned in the reactor pool or in a near place to the place. The seismic data that were used for the analysis were of the seismic catalog that it was elaborated from (1920-1982), around the place whose seismic half magnitude was of 5 grades Richter and a depth 65 km, these earthquakes are classified as shallow earthquakes, which are located in the continental plaque of North-America, these they are induced by the efforts of push of the plaque of Cocos, existing 36% of intermediate and 2 of deep earthquakes. (Author)

  13. Estimation of seismic return periods in the Laguna Verde nuclear plant; Estimacion de periodos de retorno sismico en la PNLV

    Energy Technology Data Exchange (ETDEWEB)

    Flores R, J H

    1992-01-15

    The study of seismic risk in the area of the Laguna Verde Nucleo electric plant (PNLV) and its surroundings, one carries out estimating the different return periods and the occurrence probability in different intervals of time (5, 75, 100, 125, 150 years starting from the distribution of first type of Gumbel (G1) of extreme values (Burton, 1986), the value that was used to evaluate the useful life of the PNLV was of 50 years, the other periods will be occupy to evaluate 'temporal' nuclear cemeteries, that is to say for diminish the radioactive activity of the fuel assemblies already burned in the reactor pool or in a near place to the place. The seismic data that were used for the analysis were of the seismic catalog that it was elaborated from (1920-1982), around the place whose seismic half magnitude was of 5 grades Richter and a depth 65 km, these earthquakes are classified as shallow earthquakes, which are located in the continental plaque of North-America, these they are induced by the efforts of push of the plaque of Cocos, existing 36% of intermediate and 2 of deep earthquakes. (Author)

  14. Application of the source term code package to obtain a specific source term for the Laguna Verde Nuclear Power Plant

    International Nuclear Information System (INIS)

    Souto, F.J.

    1991-06-01

    The main objective of the project was to use the Source Term Code Package (STCP) to obtain a specific source term for those accident sequences deemed dominant as a result of probabilistic safety analyses (PSA) for the Laguna Verde Nuclear Power Plant (CNLV). The following programme has been carried out to meet this objective: (a) implementation of the STCP, (b) acquisition of specific data for CNLV to execute the STCP, and (c) calculations of specific source terms for accident sequences at CNLV. The STCP has been implemented and validated on CDC 170/815 and CDC 180/860 main frames as well as on a Micro VAX 3800 system. In order to get a plant-specific source term, data on the CNLV including initial core inventory, burn-up, primary containment structures, and materials used for the calculations have been obtained. Because STCP does not explicitly model containment failure, dry well failure in the form of a catastrophic rupture has been assumed. One of the most significant sequences from the point of view of possible off-site risk is the loss of off-site power with failure of the diesel generators and simultaneous loss of high pressure core spray and reactor core isolation cooling systems. The probability for that event is approximately 4.5 x 10 -6 . This sequence has been analysed in detail and the release fractions of radioisotope groups are given in the full report. 18 refs, 4 figs, 3 tabs

  15. Simulation of overpressure events with a Laguna Verde model for the RELAP code to conditions of extended power up rate

    International Nuclear Information System (INIS)

    Rodriguez H, A.; Araiza M, E.; Fuentes M, L.; Ortiz V, J.

    2012-10-01

    In this work the main results of the simulation of overpressure events are presented using a model of the nuclear power plant of Laguna Verde developed for the RELAP/SCDAPSIM code. As starting point we have the conformation of a Laguna Verde model that represents a stationary state to similar conditions to the operation of the power station with Extended Power Up rate (EPU). The transitory of simulated pressure are compared with those documented in the Final Safety Analysis Report of Laguna Verde (FSAR). The results of the turbine shot transitory with and without by-pass of the main turbine are showed, and the event of closes of all the valves of main vapor isolation. A preliminary simulation was made and with base in the results some adjustments were made for the operation with EPU, taking into account the Operation Technical Specifications of the power station. The results of the final simulations were compared and analyzed with the content in the FSAR. The response of the power station to the transitory, reflected in the model for RELAP, was satisfactory. Finally, comments about the improvement of the model are included, for example, the response time of the protection and mitigation systems of the power station. (Author)

  16. Laguna Verde: a 120% extended power up-rate project developed by Iberdrola

    International Nuclear Information System (INIS)

    Merino Teillet, A.; Garcia-Serrano Tapia, J. L.; Ruiz Gutierrez, L.

    2010-01-01

    The experience which this document wants to present, describes the work being developed by IBERDROLA Ingenieria y Construccion, for the Laguna Verde plant in Mexico, owned by the Federal Electricity Commission (CFE). This generation plant consists of two light boiling water type units (BWR) design by General Electric in the 80's. The objective of this project is to perform the modifications on the thermal cycle of the plant required by an Extended Power Up-rate, to achieve a safe and reliable operation of the plant at 120% of its original thermal power, whilst upgrading and renovating plant equipment and installations to achieve a license renewal from 40 to 60 years of operation The consortium formed in 97% by IBERDROLA Ingenieria y Construccion SAU and in 3% by ALSTOM Mexicana, S.A. de CV, was awarded the contract in an international bid, competing against General Electric and Siemens. The project began in March 2007 and is scheduled to finalize in December 2010. At this point the work carried out include modifications of the main condenser replacement, moisture separator reheaters (MSR's) and feedwater heaters no. 5 and 6 in the two units, therefore having executed two out of four scheduled outages. The scope, development and organization of this project, whose basic elements include the design, engineering, training, supply of equipment, dismantling, installation, testing, commissioning, treatment and delivery of radioactive waste generated during the project implementation to CFE, is aimed to ensure a safe and reliable operation of the plant under the new conditions of increased thermal power of the reactor, with a thermal cycle optimized so that the gross power of the generator increase from the current 686.7 MWe to a value of 817.1 MWe in both units. An Extended Power Up-rate means an opportunity to modernize equipments, to improve maintenance, to get a better plant knowledge and to motivate the employees facing a challenging project. This project, being the

  17. Generation of the ECP database (ECP02.DAT) at the beginning of the cycle 1 of the Unit 1 of Laguna Verde; Generacion de la base ECP (ECP02.DAT) al inicio del ciclo 1 de la Unidad 1 de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Perusquia C, R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1992-10-15

    In order to carrying out a comparison among the results provided for the Program of Estimate of the ECP Critical Position and the Shutdown/Startup produced in the Cycle 1 of the Unit 1 of Laguna Verde, it was generated the base of the ECP program, following the outlines settled down in the Procedure 'Generation of ECP Database for Laguna Verde' (IT.SN/DFR 074). Next the data sheets filled when being generated the ECP02.DAT database at the beginning of the cycle are provided. In the IT.SN/DFR 079 report 'Adjustment and Preliminary Evaluation of the Predictions of Criticity of the ECP Program with Reported Data of Cycle 1 of the Unit 1 of Laguna Verde, the results of the comparison among the estimates of the ECP program using the ECP02.DAT with the real data of the Cycle 1 of the Unit 1 of Laguna Verde are presented. (Author)

  18. Recent nuclear technology advances of GE-H and GNF in partnership with CFE's Laguna Verde 2

    International Nuclear Information System (INIS)

    Cuevas V, G.; Iwamoto, T.; Banfield, J.; Calleros M, G.

    2015-09-01

    This paper is presented based on work stemming from the long-standing technical partnership between Comision Federal de Electricidad (CFE) and Global Nuclear Fuel - Americas LLC (GNF), and this paper's purpose is to provide valuable information for the nuclear industry. First, a one-to-one comparison of measurements from Gamma Thermometers (G Ts) installed in Laguna Verde 2 (LV-2) core against axially corresponding Traverse In-core Probe (Tip) measurements is remarkably close. This longest running G T plant validation for the Economic Simplified Boiling Water Reactor (ESBWR) power monitoring devices is also proving that the devices have the potential to simplify power measurements in Boiling Water Reactors (BWRs). Second, code validation results show remarkable reduction of radial power uncertainty with respect to current technology when new GNF codes for three-dimensional core simulations are compared to Tip power measurements. The LV-2 core is of paramount importance for BWR data analysis since the core has been loaded from the start of operation with different GNF fuel bundle types, fuel management has been designed with GNF codes and on-line core monitoring has been performed with GNF's 3-Dimensional Monicore system. This validation is also reliable since gamma Tips are used for local power measurements rather than thermal neutron Tips, which are more sensitive to local turbulence and positional changes. A nuclear/thermal-hydraulic core simulation of GNF fuel is undertaken from the beginning of operation of LV-2 (cycle 1) through the range of different power scenarios including low power, original licensed thermal power, power up rate and extended power up rate. Results confirm the conclusions from previous validations in different BWRs and support GNF efforts for licensing the new generation of nuclear engineering codes. (Author)

  19. Recent nuclear technology advances of GE-H and GNF in partnership with CFE's Laguna Verde 2

    Energy Technology Data Exchange (ETDEWEB)

    Cuevas V, G.; Iwamoto, T.; Banfield, J. [GE-Hitachi Nuclear Energy Americas LLC, Global Nuclear Fuel - Americas LLC, 3901 Castle Hayne Road, Wilmington, 28401 North Carolina (United States); Calleros M, G., E-mail: Gabriel.Cuevas-Vivas@age.com [Comision Federal de Electricidad, Central Nucleoelectrica de Laguna Verde, Carretera Veracruz-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2015-09-15

    This paper is presented based on work stemming from the long-standing technical partnership between Comision Federal de Electricidad (CFE) and Global Nuclear Fuel - Americas LLC (GNF), and this paper's purpose is to provide valuable information for the nuclear industry. First, a one-to-one comparison of measurements from Gamma Thermometers (G Ts) installed in Laguna Verde 2 (LV-2) core against axially corresponding Traverse In-core Probe (Tip) measurements is remarkably close. This longest running G T plant validation for the Economic Simplified Boiling Water Reactor (ESBWR) power monitoring devices is also proving that the devices have the potential to simplify power measurements in Boiling Water Reactors (BWRs). Second, code validation results show remarkable reduction of radial power uncertainty with respect to current technology when new GNF codes for three-dimensional core simulations are compared to Tip power measurements. The LV-2 core is of paramount importance for BWR data analysis since the core has been loaded from the start of operation with different GNF fuel bundle types, fuel management has been designed with GNF codes and on-line core monitoring has been performed with GNF's 3-Dimensional Monicore system. This validation is also reliable since gamma Tips are used for local power measurements rather than thermal neutron Tips, which are more sensitive to local turbulence and positional changes. A nuclear/thermal-hydraulic core simulation of GNF fuel is undertaken from the beginning of operation of LV-2 (cycle 1) through the range of different power scenarios including low power, original licensed thermal power, power up rate and extended power up rate. Results confirm the conclusions from previous validations in different BWRs and support GNF efforts for licensing the new generation of nuclear engineering codes. (Author)

  20. Results of Cable Aging Management Tests for Laguna Verde Nuclear Power Plant

    International Nuclear Information System (INIS)

    Garcia Hernandez, E.E.; Vazquez Cervantes, R.M.; Bonifacio M, J.; Garcia Garcia, J.

    2012-01-01

    Laguna Verde Nuclear Power Plant (LVNPP) located in Veracruz, Mexico is a BWR plant, two Units with 810 MWe each one, Unit 1 (1989) and Unit 2 (1990). The Equipment Qualification (EQ) Group at the Nuclear Research National Institute (ININ) has been working with the plant on tasks to develop the LVNPP cables Aging Management Program (AMP), as part of the technical basis to extend the operational life of the plant through license renewal up to 60 years. LVNPP cables are qualified for 40 years plus a LOCA DBA in accordance with 10.CFR 50.49 and the IEEE Std-323 and IEEE St. 383. The first studies for cables AMP have been performed with samples of safety related I and C cables taken from the LVNPP warehouse, similar brands and models as installed at the plant. ININ applied the condition monitoring techniques to these samples to identify predictive degradation and to establish the methodology for cables AMP, focused to the LVNPP license renewal. Cable tests program has been running at the EQ Lab in ININ, performing accelerated aging by steps up to 60 years and to 40 years plus a LOCA test. Determination for Activation Energy (Ea) and Oxidation Induction Time (OIT) methods were developed applying a DSC/TGA calorimeter. (author)

  1. Geological-Geophysical integration in the Laguna Verde Nuclear Power Plant site and its surroundings

    International Nuclear Information System (INIS)

    Flores Ruiz, J.H.

    1990-01-01

    As part of comprehensive, nationwide evaluation of the Seismic risk at the Nuclear Power Plant site of the Laguna Verde (LVNP) the first of the acceleration ground motion maps, covering for a circular distance value 200 Km around, has been prepared. The maps were created the acceleration grounds motion expected over intervals 1, 25, 50, 100 and 200 years by using Gumbel's (I, III) theory of extreme value statistics of the seismic data. It's reaching operating basis earthquake (OBE) value 0.1 g. in 100 years forecasting and 200 years this value is 0.114 G is more than OBE, but minor than safety shutdown earthquake (SSE). The acceleration ground motion risk maps are compared to regional geology, seismicity (1920-1982) and gravity data. Good correlations are found between the accelerations ground motion risk and seismicity. A spatial correlation observed between gravity and structure with acceleration ground motion rise is considered a secondary the structural effect. Locations of the currently operating NPP correspond to low seismicity risk area. Based on these comparations, it is concluded that the method provides geologically reasonable results which are usable in a nationwide NPP assessment program (Author)

  2. Implementation of the project of equipment reliability in the nuclear power plant of Laguna Verde

    International Nuclear Information System (INIS)

    Rios O, J. E.; Martinez L, A. G.

    2008-01-01

    A equipment is reliable if it fulfills the function for which was designed and when it is required. To implement a project of reliability in a nuclear power plant this associate to a process of continuous analysis of the operation, of the conditions and faults of the equipment. The analysis of the operation of a system, of the equipment of the same faults and the parts that integrate to equipment take to identify the potential causes of faults. The predictive analysis on components and equipment allow to rectify and to establish guides to optimize the maintenance and to guarantee the reliability and function of the same ones. The reliability in the equipment is without place to doubts a wide project that embraces from the more small component of the equipment going by the proof of the parts of reserve, the operation conditions until the operative techniques of analysis. Without place of doubt for a nuclear power plant the taking of decisions based on the reliability of their systems and equipment will be the appropriate for to assure the operation and reliability of the same one. In this work would appear the project of reliability its processes, criteria, indicators action of improvement and the interaction of the different disciplines from the Nuclear Power Plant of Laguna Verde like a fundamental point for it put in operation. (Author)

  3. Economic analysis of extended cycles in the Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Hernandez N, H.; Hernandez M, J.L.; Francois L, J.L.

    2004-01-01

    The present work presents a preliminary analysis of economic type of extended cycles of operation of the Unit One in the Laguna Verde nuclear power plant. It is analysed an equilibrium cycle of 18 months firstly, with base to the Plan of Use of Energy of the Federal Commission of Electricity, being evaluated the cost of the energy until the end of the useful life of the plant. Later on an alternative recharge scenario is presented with base to an equilibrium cycle of 24 months, implemented to the beginning of the cycle 11, without considering transition cycles. It is added in both cycles the cost of the substitution energy, considering the unitary cost of the fuel of a dual thermoelectric power station of 350 M We and evaluating in each operation cycle, in both scenarios, the value of the substitution energy. The results show that a reduction of the days of recharge in the cycle of 24 months could make this option but favorable economically. The duration of the period of recharge rebounds in considerable grade in the cost of energy generation for concept of fuel. (Author)

  4. Modeling of the vapor cycle of Laguna Verde with the PEPSE code to conditions of thermal power licensed at present (2027 MWt)

    International Nuclear Information System (INIS)

    Castaneda G, M. A.; Maya G, F.; Medel C, J. E.; Cardenas J, J. B.; Cruz B, H. J.; Mercado V, J. J.

    2011-11-01

    By means of the use of the performance evaluation of power system efficiencies (PEPSE) code was modeled the vapor cycle of the nuclear power station of Laguna Verde to reproduce the nuclear plant behavior to conditions of thermal power, licensed at present (2027 MWt); with the purpose of having a base line before the implementation of the project of extended power increase. The model of the gauged vapor cycle to reproduce the nuclear plant conditions makes use of the PEPSE model, design case of the vapor cycle of nuclear power station of Laguna Verde, which has as main components of the model the great equipment of the vapor cycle of Laguna Verde. The design case model makes use of information about the design requirements of each equipment for theoretically calculating the electric power of exit, besides thermodynamic conditions of the vapor cycle in different points. Starting from the design model and making use of data of the vapor cycle measured in the nuclear plant; the adjustment factors were calculated for the different equipment s of the vapor cycle, to reproduce with the PEPSE model the real vapor cycle of Laguna Verde. Once characterized the model of the vapor cycle of Laguna Verde, we can realize different sensibility studies to determine the effects macros to the vapor cycle by the variation of certain key parameters. (Author)

  5. Study of environmental noise in a BWR plant like the Nuclear Power Plant Laguna Verde; Estudio de ruido ambiental en una planta BWR como la Central Nuclear Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Tijerina S, F.; Cruz G, M.; Amador C, C., E-mail: francisco.tijerina@cfe.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Subgerencia de Ingenieria, Carretera Cardel-Nautla Km. 42.5, Alto Lucero, Veracruz (Mexico)

    2013-10-15

    In all industry type the health costs generated by the noise are high, because the noise can cause nuisance and to harm the capacity to work when causing tension and to perturb the concentration, and in more severe cases to reach to lose the sense of the hearing in the long term. The noise levels in the industry have been designated for the different types of use like residential, commercial, and industrial and silence areas. The noise can cause accidents when obstructing the communications and alarm signs. For this reason the noise should be controlled and mitigated, at a low level as reasonably is possible, taking into account that the noise is an acoustic contamination. The present study determines a bases line of the environmental noise levels in a nuclear power plant BWR-5 as Laguna Verde, (like reference) to be able to determine and to give pursuit to the possible solutions to eliminate or to limit the noise level in the different job areas. The noise levels were registered with a meter of integrative noise level (sonometer) and areas of noise exposure levels mapping the general areas in the buildings were established, being the registered maximum level of 96.94 dba in the building of the Reactor-elevation 0.65 m under the operation conditions of Extended Power Up rate (EPU) of 120% PTN. Knowing that the exposition to noises and the noise dose in the job place can influence in the health and in the safety of the workers, are extensive topics that they should be analyzed for separate as they are: to) the effects in the health of the exposure to the noise, b) how measuring the noise, c) the methods and technologies to combat and to control the noise in the industry by part of engineering area and d) the function of the industrial safety bodies as delegates of the health and safety in the task against the noise in the job. (author)

  6. Participation of the ININ in the external radiological emergency plan of the Laguna Verde power plant; Participacion del ININ en el plan de emergencia radiologica externo de la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Martinez S, R; Cervini L, A [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1991-07-01

    The planning of performances in radiological emergencies, with the object of reducing the consequences as much as possible on the population to accidental liberations of radioactive material coming from Nuclear power plant, it has been of main interest in the nuclear community in the world. In Mexico it has not been the exception, since with the setting in march of the Laguna Verde nuclear power plant exists an executive program of planning for emergencies that it outlines the activities to follow trending to mitigate the consequences that are derived of this emergency. As integral part of this program this the External Plan of Radiological Emergency (PERE) that covers the emergencies that could leave the frontiers of the Laguna Verde power plant. In the PERE it settles down the planning, address and control of the preparation activities, response and recovery in emergencies, as well as the organization and coordination of the institutions that participate. The National Institute of Nuclear Research (ININ), like integral part of these institutions in the PERE, has an infrastructure that it allows to participate in the plan in a direct way in the activities of 'Control of the radiological exhibition the response personnel and control of water and foods' and of support way and consultant ship in the activities of 'Monitoring, Classification and decontamination of having evaluated' and 'Specialized medical radiological attention'. At the moment the ININ has a radiological mobile unit and this conditioning a second mobile unit to carry out part of the activities before mentioned; also accounts with 48 properly qualified people that directly intervene in the plan. In order to guarantee an adequate response in the PERE an organization it has been structured like that of the annex as for the personnel, transport, team, procedures and communication system, with the objective always of guaranteeing the security and the population's health in emergency situations in the

  7. Strategic planning 2007-2011, an opportunity for quality, competitiveness and excellence of the Laguna Verde Central; Planeacion estrategica 2007-2011, una oportunidad para la calidad, competitividad y excelencia de la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Rivera C, A. [CFE, Central Laguna Verde, Kilometro 42.5 Cardel Nautla, Veracruz (Mexico)]. e-mail: arr99999@cfe.gob.mx

    2007-07-01

    The reason is to give to know to the nuclear community in Mexico the good results that it located in the 2006 to the Laguna Verde Nucleo electric Central in the classification of the World Association of Nuclear Operators (WANO) like one of the best in the worldwide scale, and their Strategic Plan 2007-2011 like an opportunity to continue improving the Quality, the Competitiveness and the Excellency in their Generating Units. It stands out that the fuel reloads are carried out in systemic form in less than 30 days, and also other achievements like it is the certificate granted by PROFEPA of Clean Industry, the renovation of the Certifications of the ISO-9001 and the ISO-14001, as well as the accredit of the Laboratories, and they will give data of the project of the increment of power that their power rose in 15%. For those results in the Strategic Planning 2007-2011 are pointed out that the Laguna Verde Central is a highly viable option in Mexico, when continuing with reloads that will allow a capacity factor up of 90%, and the other concepts that will give the obtaining of the qualification level 1 of WANO in this strategic period. Finally I will conclude with the good news for the Nuclear Industry in Mexico that published the Reforma newspaper at November 01, 2006: 'To the president of Mexico, Felipe Calderon, interests him to impel during his command the alternating energy sources to the hydrocarbons, known it is that the hydrocarbons (petroleum, coal or natural gas) they are finite, while the appetite of the world for the energy is infinite. As you they know, Mexico possesses a nuclear plant that generates energy starting from enriched uranium: the famous Laguna Verde Thermonuclear Central. He declared that Mexico can and it should advance for the one on the way to the energy generation for the nuclear road.' (Author)0.

  8. Internal event analysis for Laguna Verde Unit 1 Nuclear Power Plant. Accident sequence quantification and results; Analisis de eventos internos para la Unidad 1 de la Central Nucleoelectrica de Laguna Verde. Cuantificacion de secuencias de accidente y resultados

    Energy Technology Data Exchange (ETDEWEB)

    Huerta B, A; Aguilar T, O; Nunez C, A; Lopez M, R [Comision Nacional de Seguridad Nuclear y Salvaguardias, 03000 Mexico D.F. (Mexico)

    1994-07-01

    The Level 1 results of Laguna Verde Nuclear Power Plant PRA are presented in the {sup I}nternal Event Analysis for Laguna Verde Unit 1 Nuclear Power Plant, CNSNS-TR 004, in five volumes. The reports are organized as follows: CNSNS-TR 004 Volume 1: Introduction and Methodology. CNSNS-TR4 Volume 2: Initiating Event and Accident Sequences. CNSNS-TR 004 Volume 3: System Analysis. CNSNS-TR 004 Volume 4: Accident Sequence Quantification and Results. CNSNS-TR 005 Volume 5: Appendices A, B and C. This volume presents the development of the dependent failure analysis, the treatment of the support system dependencies, the identification of the shared-components dependencies, and the treatment of the common cause failure. It is also presented the identification of the main human actions considered along with the possible recovery actions included. The development of the data base and the assumptions and limitations in the data base are also described in this volume. The accident sequences quantification process and the resolution of the core vulnerable sequences are presented. In this volume, the source and treatment of uncertainties associated with failure rates, component unavailabilities, initiating event frequencies, and human error probabilities are also presented. Finally, the main results and conclusions for the Internal Event Analysis for Laguna Verde Nuclear Power Plant are presented. The total core damage frequency calculated is 9.03x 10-5 per year for internal events. The most dominant accident sequences found are the transients involving the loss of offsite power, the station blackout accidents, and the anticipated transients without SCRAM (ATWS). (Author)

  9. Strategic planning 2007-2011, an opportunity for quality, competitiveness and excellence of the Laguna Verde Central

    International Nuclear Information System (INIS)

    Rivera C, A.

    2007-01-01

    The reason is to give to know to the nuclear community in Mexico the good results that it located in the 2006 to the Laguna Verde Nucleo electric Central in the classification of the World Association of Nuclear Operators (WANO) like one of the best in the worldwide scale, and their Strategic Plan 2007-2011 like an opportunity to continue improving the Quality, the Competitiveness and the Excellency in their Generating Units. It stands out that the fuel reloads are carried out in systemic form in less than 30 days, and also other achievements like it is the certificate granted by PROFEPA of Clean Industry, the renovation of the Certifications of the ISO-9001 and the ISO-14001, as well as the accredit of the Laboratories, and they will give data of the project of the increment of power that their power rose in 15%. For those results in the Strategic Planning 2007-2011 are pointed out that the Laguna Verde Central is a highly viable option in Mexico, when continuing with reloads that will allow a capacity factor up of 90%, and the other concepts that will give the obtaining of the qualification level 1 of WANO in this strategic period. Finally I will conclude with the good news for the Nuclear Industry in Mexico that published the Reforma newspaper at November 01, 2006: 'To the president of Mexico, Felipe Calderon, interests him to impel during his command the alternating energy sources to the hydrocarbons, known it is that the hydrocarbons (petroleum, coal or natural gas) they are finite, while the appetite of the world for the energy is infinite. As you they know, Mexico possesses a nuclear plant that generates energy starting from enriched uranium: the famous Laguna Verde Thermonuclear Central. He declared that Mexico can and it should advance for the one on the way to the energy generation for the nuclear road.' (Author)

  10. Preliminary evaluation of the profitability indexes of the Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Villanueva M, C.

    2010-10-01

    The Laguna Verde nuclear power plant of the Federal Commission of Electricity has an installed capacity of 1,350 MW and unit 1 started commercial operation in 1990 and unit 2 in 1995. This paper is a synthesis of the results of a preliminary evaluation of the expected profitability indexes of the power plant during an economic lifetime of 40 years. The following data was used as input to the evaluation model prescribed by the Finance and Public Credit Secretary for public investment projects. Unit investment cost: 3,500 US D/k W; Fixed operation and maintenance cost: 54. 45 US D/year-k W; Variable operation and maintenance cost: 0. 38 US D/M Wh; Nuclear fuel cycle cost: 10. 28 US D/M Wh; Lifetime capacity factor: 85%; Discount rate: 12.0% per year; Sale price of electricity to the interconnected electric system: 80. 75 US D/M Wh. The output of the evaluation model is the following: Cost of electricity generated: 60. 2 1 US D/M Wh; fixed cost 49. 55 US D/M Wh; variable cost 10. 66 US D/M Wh; Internal rate of return (Irr): 18.0%; Benefit to cost quotient (B/C): 1.341. A very systematic sensitivity analysis was done, that shows that the cost is very sensitive to the capacity factor and to the investment cost, but is very insensitive to the fixed operation and maintenance cost and to the nuclear fuel cost. Finally, a comparison was made to the evaluation of the profitability indexes of a natural gas fired combined cycle power plant. (Author)

  11. Optimization of reloading Laguna Verde Central U1/U2, Federal Electricity Commission

    International Nuclear Information System (INIS)

    Espinosa G, J.M.

    2006-01-01

    The Laguna Verde Central from the beginning of the commercial operation settled down as maximum priority 'the total safety in its operation' taking in consideration the so much experience of the good operation and of multiple recharges made in a sure and reliable way, and without separate us of the safety mystic of the CLV, but looking for to be better every day a new challenge it settled down 'to compare us with the best plants in the world' and certainly to work to classify us like one of them. For this we established a 4.0 year old plan (2003/2006) for the effectiveness all the processes in the power station that allowed us to measure our acting with the same parameters that settle down at international level (nuclear safety, industrial safety, radiological safety, capacity factor, readiness factor, cleaning of the power station, attachment to procedures, attention to the detail and certainly to be competitive in the economic aspect, summing up means to be good in all the aspects). All the above mentioned would allow us to qualify us as level 1 of WANO (world proprietors association of nuclear centrals) at the end of the year 2006 and to pass to be part of this select group. After analyzing the acting record of the power station, evaluating our technical and economic capacity, the location of the installation besides revising the international experiences was defined that one of the concepts that impact considerably so much to the capacity factors and availability besides the dose and production cost is the duration of the recharge periods, for this reason the present work is elaborated. (Author)

  12. Planning of activities in the Laguna Verde Central planning at 12 weeks

    International Nuclear Information System (INIS)

    Chimalpopoca, C.

    2007-01-01

    The universe of works that are carried out in a nuclear facility to maintain effective the structures, systems and components require of a continuous analysis, in the order of the maintenance frequencies that can be of the preventive, predictive or corrective type. Each component is associated to reserve parts, readiness of systems, in fulfillment to the operation technical specifications, to the environment of the one work; each component requires of a planning level, where it is distinguished with clarity when they are executed, in the operation stage, stop or recharge. This work has as end to show like the activities are planned during the operation, using planning methods to twelve weeks, where the reach of the task is conceptualized, operative requirements, of reserve parts, of the work environment analysis, of those radiological conditions, of the authorizations for their execution, the same execution and the evaluation post work like a technique to maintain in continuous improvement the tasks of the maintenance of the Units of the Power station. A motor valve to be worked in its internals requires access to the work point, it requires bill of the system, electric disconnection, maneuvers to disassemble actuators and retirement of thermal isolation if it applies, reserve parts of the caps joints, control mechanisms, personal, tools, radiological control. The success of the continuous operation of a power station is in the planning quality, the attention of each one of the details to assure that the components, structures and components stay effective to make their function when they are demanded. The planning task requires of experience and knowledge of each some of the components, the task of planning of activities and its execution is multidisciplinary This work has that purpose, to show the planning tools in the Laguna Verde Nuclear Power station, under the concept of twelve weeks. (Author)

  13. Three stops of fuel reloading with length of less 30 days in the Laguna Verde Central

    International Nuclear Information System (INIS)

    Lozano L, A.

    2007-01-01

    The Laguna Verde Central having established as mission 'With maximum priority in the safety, to generate electricity by nuclear means with quality and cost competitive, sustained in our personnel's continuous overcoming and deep respect to the environment' and respecting our values (safety, responsibility by results, professional integrity, continuous improving, team working, excellence in the acting, quality of service, protection to the environment) they thought about our strategic objectives of the power station being born this way one of them that it is the program of improvement 'Reduction of reload times' looking for to be improves every day comparing us with the best plants in the world efficient all the processes in the power station that allowed us to measure our acting with the same parameters that settle down at international level like they are nuclear safety, industrial safety, radiological safety, capacity factor, readiness factor, cleaning of the power station attachment to procedures, attention to the detail and certainly to be competitive in the economic aspect. After analyzing the acting record of the power station, evaluating our technical capacity, economic, the location of the installation besides revising the international experiences it was defined that one of the concepts that impact considerably so much to the capacity and readiness factors besides the dose and production cost is the duration of the reload periods, for this reason they were elaborated work strategies to be able to reach our goal of reload days considered in being able to carry out them in less than 30 days, here the actions carried out that they made us complete the three last reloads in less than 30 days are captured. (Author)

  14. Application of six sigma to reloads design of the Laguna Verde Central with length until 17 days; Aplicacion de seis sigma para disenar recargas de la Central Laguna Verde con duracion hasta de 17 dias

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa G, J.M. [Comision Federal de Electricidad, Central Laguna Verde, Subgerencia General de Operacion, Planeacion, Veracruz (Mexico)]. e-mail: mespinos@cfe.gob.mx

    2007-07-01

    The more important value in the Laguna Verde Central it is the safety. The international experience it confirms us that the more safe plants its are those more productive, this conclusion and reasoning indicate to the power station that we are in the correct road, improving the acting we will obtain that greater interest for us in the Laguna Verde Central (to increase the safety) and as added value to be able to be one of the best business for the Federal Commission of Electricity. With a future vision and commitment of high acting was integrated in an external place to all the area headquarters: (Maintenance, Planning, Operation, Parts of Reserve, Finances, Contracts, Supplies, Warehouse, design Engineering, place Engineering, engineering of systems, radiological Protection, etc.) to carry out a combined work with the unique challenge of drifting with the biggest level detail the program of a recharge and certainly to get ready to achieve their execution (all this without omitting any consideration for smaller or simpler than it seemed), looking for high quality in the works, with and bigger level of safety, with the minimum possible dose, the more reasonable cost and considering a new concept of human character, to achieve the above-mentioned without the participant personnel's stress, with the premise that a good plan and commitment of all the only one that it can bring us as result it is the success of the whole organization. (Author)

  15. 15 years of production of electric energy of the Laguna Verde power plant, its plans and future; 15 anos de produccion de energia electrica de la Central Laguna Verde, sus planes y futuro

    Energy Technology Data Exchange (ETDEWEB)

    Rivera C, A [CFE, Central Laguna Verde, Km. 42.5 Carretera Cardel-Nautla, Veracruz (Mexico)

    2005-07-01

    In the year 2005 Laguna Verde power plant reaches 15 years of producing electric power in Mexico arriving to but of 100 million Megawatts-hour from their beginning of commercial activities. The Unit 1 that entered at July 29, 1990 and the Unit 2 at April 10, 1995, obtaining the Disposability Factors from their origin is: 84.63% in Unit 1 and 83.67% in Unit 2. The march of the X XI century gives big challenges of competition to the Laguna Verde Central, with the possible opening of the electric market to private investment, for their Goals and Objectives of a world class company, taking the evaluation system and qualification of the World Association of Nuclear Operators (WANO) that promotes the Excellence in the operation of the nuclear power stations in all their partners. This Association supports the development of programs that allow the monitoring of the behavior in Safety Culture, Human fulfilment, Equipment reliability, Industrial Safety, Planning, Programming and Control, Personalized Systematic Training, and the use of the Operational experience in the daily tasks. The present work tries to explain the system of evaluation/qualification of WANO, the definition of Goals and Objectives to reach the excellence and of the programs, it will present the Program of the Reliability of Equipment with its main actions the productivity. (Author)

  16. Perspectives of the central Laguna Verde after Fukushima for the period 2012 at the 2015 in operation and maintenance; Perspectivas de la central Laguna Verde despues de Fukushima para el periodo 2012 al 2015 en operacion y mantenimiento

    Energy Technology Data Exchange (ETDEWEB)

    Rivera C, A., E-mail: arr99999@cfe.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Carretera Cardel-Nautla Km 42.5, Veracruz (Mexico)

    2012-10-15

    The Nuclear Power Plants Management of the Federal Commission of Electricity in Mexico by means an internal analysis confronts the threat to the nuclear industry of the event of Fukushima that affected the public opinion, and the emission of new regulations. This situation demands to improve the results of the operation and maintenance of the nuclear power plant of Laguna Verde, to contribute value with their excellence in the acting to the nuclear option in Mexico. The internal analysis defined with clarity the perspectives based on weaknesses and strengths of the operation (monitoring and control of on-line parameters), and in the maintenance (sustained by the planning), enriched with the external experiences emitted by the institutes INPO and WANO for the nuclear industry, with all this strategic objectives 2012 to 2015 were presented and the initiatives as the extension of the useful life to 20 years more, as well as the focused actions to diminish the threat that the event of Fukushima influenced negatively in the public opinion, by means the diffusion of the good results that can be obtained in the nuclear power plant of Laguna Verde between 2012 and 2015, taking advantage of its modernized power of 810 MW-hour for each generating unit, doing visible that the Project of Extended Power Increase is a generation reality of 120% of the original value, to be able to enter at the excellence levels of the nuclear world. (Author)

  17. Application of six sigma to reloads design of the Laguna Verde Central with length until 17 days

    International Nuclear Information System (INIS)

    Espinosa G, J.M.

    2007-01-01

    The more important value in the Laguna Verde Central it is the safety. The international experience it confirms us that the more safe plants its are those more productive, this conclusion and reasoning indicate to the power station that we are in the correct road, improving the acting we will obtain that greater interest for us in the Laguna Verde Central (to increase the safety) and as added value to be able to be one of the best business for the Federal Commission of Electricity. With a future vision and commitment of high acting was integrated in an external place to all the area headquarters: (Maintenance, Planning, Operation, Parts of Reserve, Finances, Contracts, Supplies, Warehouse, design Engineering, place Engineering, engineering of systems, radiological Protection, etc.) to carry out a combined work with the unique challenge of drifting with the biggest level detail the program of a recharge and certainly to get ready to achieve their execution (all this without omitting any consideration for smaller or simpler than it seemed), looking for high quality in the works, with and bigger level of safety, with the minimum possible dose, the more reasonable cost and considering a new concept of human character, to achieve the above-mentioned without the participant personnel's stress, with the premise that a good plan and commitment of all the only one that it can bring us as result it is the success of the whole organization. (Author)

  18. Perspectives of the central Laguna Verde after Fukushima for the period 2012 at the 2015 in operation and maintenance

    International Nuclear Information System (INIS)

    Rivera C, A.

    2012-10-01

    The Nuclear Power Plants Management of the Federal Commission of Electricity in Mexico by means an internal analysis confronts the threat to the nuclear industry of the event of Fukushima that affected the public opinion, and the emission of new regulations. This situation demands to improve the results of the operation and maintenance of the nuclear power plant of Laguna Verde, to contribute value with their excellence in the acting to the nuclear option in Mexico. The internal analysis defined with clarity the perspectives based on weaknesses and strengths of the operation (monitoring and control of on-line parameters), and in the maintenance (sustained by the planning), enriched with the external experiences emitted by the institutes INPO and WANO for the nuclear industry, with all this strategic objectives 2012 to 2015 were presented and the initiatives as the extension of the useful life to 20 years more, as well as the focused actions to diminish the threat that the event of Fukushima influenced negatively in the public opinion, by means the diffusion of the good results that can be obtained in the nuclear power plant of Laguna Verde between 2012 and 2015, taking advantage of its modernized power of 810 MW-hour for each generating unit, doing visible that the Project of Extended Power Increase is a generation reality of 120% of the original value, to be able to enter at the excellence levels of the nuclear world. (Author)

  19. 15 years of production of electric energy of the Laguna Verde power plant, its plans and future

    International Nuclear Information System (INIS)

    Rivera C, A.

    2005-01-01

    In the year 2005 Laguna Verde power plant reaches 15 years of producing electric power in Mexico arriving to but of 100 million Megawatts-hour from their beginning of commercial activities. The Unit 1 that entered at July 29, 1990 and the Unit 2 at April 10, 1995, obtaining the Disposability Factors from their origin is: 84.63% in Unit 1 and 83.67% in Unit 2. The march of the X XI century gives big challenges of competition to the Laguna Verde Central, with the possible opening of the electric market to private investment, for their Goals and Objectives of a world class company, taking the evaluation system and qualification of the World Association of Nuclear Operators (WANO) that promotes the Excellence in the operation of the nuclear power stations in all their partners. This Association supports the development of programs that allow the monitoring of the behavior in Safety Culture, Human fulfilment, Equipment reliability, Industrial Safety, Planning, Programming and Control, Personalized Systematic Training, and the use of the Operational experience in the daily tasks. The present work tries to explain the system of evaluation/qualification of WANO, the definition of Goals and Objectives to reach the excellence and of the programs, it will present the Program of the Reliability of Equipment with its main actions the productivity. (Author)

  20. Modeling of the vapor cycle of Laguna Verde with the PEPSE code to conditions of thermal power licensed at present (2027 MWt); Modelado del ciclo de vapor de Laguna Verde con el codigo PEPSE a condiciones de potencia termica actualmente licenciada (2027 MWt)

    Energy Technology Data Exchange (ETDEWEB)

    Castaneda G, M. A.; Maya G, F.; Medel C, J. E.; Cardenas J, J. B.; Cruz B, H. J.; Mercado V, J. J., E-mail: miguel.castaneda01@cfe.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Carretera Cardel-Nautla Km 42.5, Veracruz (Mexico)

    2011-11-15

    By means of the use of the performance evaluation of power system efficiencies (PEPSE) code was modeled the vapor cycle of the nuclear power station of Laguna Verde to reproduce the nuclear plant behavior to conditions of thermal power, licensed at present (2027 MWt); with the purpose of having a base line before the implementation of the project of extended power increase. The model of the gauged vapor cycle to reproduce the nuclear plant conditions makes use of the PEPSE model, design case of the vapor cycle of nuclear power station of Laguna Verde, which has as main components of the model the great equipment of the vapor cycle of Laguna Verde. The design case model makes use of information about the design requirements of each equipment for theoretically calculating the electric power of exit, besides thermodynamic conditions of the vapor cycle in different points. Starting from the design model and making use of data of the vapor cycle measured in the nuclear plant; the adjustment factors were calculated for the different equipment s of the vapor cycle, to reproduce with the PEPSE model the real vapor cycle of Laguna Verde. Once characterized the model of the vapor cycle of Laguna Verde, we can realize different sensibility studies to determine the effects macros to the vapor cycle by the variation of certain key parameters. (Author)

  1. Experiences with the technical cooperation project TC MEX 04/53. Evaluation of the integrity and extension of life of the Laguna Verde nuclear power plant. Management program of the plant life (PLIM)

    International Nuclear Information System (INIS)

    Arganis J, C.R.; Aguilar T, J.A.; Guevara M, A.; Garcia M, C.; Martinez G, R.R.; Griz C, M.M.; Sanchez M, M.A.; Diaz O, R.C.

    2006-01-01

    In the biennium 2005-2006 the project of technical cooperation with the International Atomic Energy Agency OIEA TC MEX 04/53 'Evaluation of the integrity and extension of life of the Laguna Verde nuclear power plant Plant life handling program (PLIM)' was approved, which has as objective the one to begin the actions to apply the methodology of Handling of life of Plant (PLIM) in the Unit I (Ul) of the Laguna Verde Nucleo electric Central (CNLV), in order to obtain the Renovation of License (LR), in a long term (2020). To apply this methodology 5 systems they were selected, structures or components (SEC) to carry out the handling programs of the one aging (AMP), and PLIM which are: The encircling of the reactor core (Core Shroud), the pressure vessel of the reactor (Reactor Pressure Vessel), the one primary container (Primary Containment), the system of feeding water (Reactor Feed Water) and cables, which were not in this work to be of another nature. The report presents the more important aspects considered in these systems for their programs of AMP and PLIM, as like a revision of those selection processes and evaluation (screening and scoping) for the application of PLIM in the systems of the Ul of the CNLV. (Author)

  2. Rehabilitation and modernization project of units 1 and 2 of Laguna Verde Nuclear Power Plant. A strengthening project to 120%. (2nd phase)

    International Nuclear Information System (INIS)

    Liebana, B.; Merino, A.; Garcia, J. L.; Gomez, M.; Martinez, I.; Ruiz, L.

    2010-01-01

    The power increase of the Laguna Verde Nuclear Power Plant is a project for the rehabilitation and modernization of the turbo and associated equipment to get an increase of its power and of its service life. The project scope includes the design, the engineering, the equipment supply, the installation, the testing and the commissioning. This article presents the work of the second phase.

  3. The National Institute of Nuclear Research (ININ) and its participation in the External Radiological Emergency Plans at Laguna Verde Power plant

    International Nuclear Information System (INIS)

    Suarez, G.

    1998-01-01

    In this article it is described the form in which the ININ participates in the External Radiological Emergency Plan at Laguna Verde Power plant. It is set the objective, mission and organization of this plan. The responsibilities and activities that plan has assigned are mentioned also the organization to fulfil them and the obtained results during 9 years of participation. (Author)

  4. Experiences with the technical cooperation project TC MEX 04/53. Evaluation of the integrity and extension of life of the Laguna Verde nuclear power plant. Management program of the plant life (PLIM); Experiencias con el proyecto de cooperacion tecnica TC MEX 04/53. Evaluacion de la integridad y extension de vida de la planta de potencia nuclear Laguna Verde. Programa de Manejo de vida de planta (PLIM)

    Energy Technology Data Exchange (ETDEWEB)

    Arganis J, C.R.; Aguilar T, J.A. [ININ, 52750 Ocoyoacac, Estado de Mexico (Mexico); Guevara M, A.; Garcia M, C.; Martinez G, R.R.; Griz C, M.M.; Sanchez M, M.A.; Diaz O, R.C. [CFE, Subgerencia de Ingenieria, Carretera Veracruz-Medellin, Km. 7.5 Veracruz (Mexico)]. e-mail: craj@nuclear.inin.mx

    2006-07-01

    In the biennium 2005-2006 the project of technical cooperation with the International Atomic Energy Agency OIEA TC MEX 04/53 'Evaluation of the integrity and extension of life of the Laguna Verde nuclear power plant Plant life handling program (PLIM)' was approved, which has as objective the one to begin the actions to apply the methodology of Handling of life of Plant (PLIM) in the Unit I (Ul) of the Laguna Verde Nucleo electric Central (CNLV), in order to obtain the Renovation of License (LR), in a long term (2020). To apply this methodology 5 systems they were selected, structures or components (SEC) to carry out the handling programs of the one aging (AMP), and PLIM which are: The encircling of the reactor core (Core Shroud), the pressure vessel of the reactor (Reactor Pressure Vessel), the one primary container (Primary Containment), the system of feeding water (Reactor Feed Water) and cables, which were not in this work to be of another nature. The report presents the more important aspects considered in these systems for their programs of AMP and PLIM, as like a revision of those selection processes and evaluation (screening and scoping) for the application of PLIM in the systems of the Ul of the CNLV. (Author)

  5. Impact on the bar value in hot by the introduction of advanced control bars in the Unit 1 of the Laguna Verde Nuclear power plant

    International Nuclear Information System (INIS)

    Montes, J.L.; Perusquia, R.; Ortiz, J.J.; Hernandez, J.L.; Ramirez, J.R.

    2004-01-01

    In recent dates the Laguna Verde Nuclear Power station (CNLV) has acquired new designs of control bars, this new type of bars presents modifications important in their design. For what is important to analyze their performance inside those reactors of this nuclear power station. Presently work is shown the behavior of the nucleus of the reactor in hot condition (HFP) when three different types of control bar are used. The first of them corresponds the one that initially has been used in this power station and that we will call original. The second type of control bars, it corresponds to an advanced type and it is the first design different from the original and it corresponds to a bar design that it includes Hafnium (Hf) like one of their neutronic absorption characteristics. The third, denoted as 2AV, include besides the material of the second type new design characteristics, and it is the last finish bar type that it has been introduced in the operation of the reactors of the CNLV. With base in the studied cases is found that the bars 2AV have a total power value, 7.6 % bigger respect the bars 1AV; and in turn the bars 1AV, 6.1 % bigger with respect the ORG control bars. (Author)

  6. 30 years in the Veracruz state coast landscape: Laguna Verde nuclear power station. 1. ed.; 30 anos de paisaje costero veracruzano: Central Nucleoelectrica Laguan Verde

    Energy Technology Data Exchange (ETDEWEB)

    Guevara, S; Moreno Casasola, P; Castillo Campos, G; Dorantes, C; Gonzalez Garcia, F; Halffter, G; Isunza, E; Lot H, A; Mendoza, R; Paradowska, K; Priego, A; Sanchez Vigil, C; Vazquez, G [Comision Federal de Electricidad and Instituto Nacional de Ecologia A.C. (Mexico)

    2008-07-01

    36 years ago one of the most important power projects of Mexico was born; the design and construction of the Nuclear power station Laguna Verde. This project became reality thanks to the commitment of a group of Mexican professionals that gave the best of them for its accomplishment. At that time, there was not in Mexico a legislation that contemplated the environmental protection; nevertheless, the Mexican Constitution anticipates that when in the country there is not legislation for the development of a project, this must adopt the legislation of the country that is selling it. In the specific case of Laguna Verde, the legislation of the United States of America was adopted and in the environmental part it had to issue the first Manifest of Environmental impact, that was called Informe Ambiental para la Contruccion de Laguna Verde en el Estado de Veracruz. This study was performed by several national as well as foreign institutions. Among the most outstanding are the Universidad Nacional Autonoma de Mexico, the Intituto Politecnico Nacional, the Universidad Veracruzana, the Intituto National para la Investigacion de Recursos Biologicos, the Instituto de Ecologia, A.C. With this report, the engineers undertook the task of designing and constructing, the biologists and ecologists to realize the studies to mitigate the effects caused to the environment during the construction and later, during the operation of the Nuclear power station. After 18 years of commercial operation of the power station the present book is completed, in which the results obtained in 1972, when the studies of the environmental report began are compared against the ones obtained throughout this period. It is important to see in the results of the different studies and indicators presented/displayed in this book, that the important changes on the environment are due, to the change of the ground use and the over-exploitation of the natural resources as it happens in almost all the country. The

  7. Improvements to the RELAP/SCDAPSIM of Laguna Verde model for the analysis of transients and accidents; Mejoras al modelo de Laguna Verde de RELAP/SCDAPSIM para el analisis de transitorios y accidentes

    Energy Technology Data Exchange (ETDEWEB)

    Amador G, R.; Castillo D, R.; Ortiz V, J.; Araiza M, E.; Martinez C, E., E-mail: rogelio.castillo@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2016-09-15

    This work presents the improvements to the integral model of the nuclear power plant of Laguna Verde for the RELAP/SCDAPSIM code, for the simulation of transients and severe accidents. The model includes a new detailed geometry of the steam lines, as well as improvements in the performance of the emergency systems. A primary containment model has also been created, which will be used to analyze the effect of safety valve and relief valve discharges to the wet well suppression pool and the effect of the rupture of a recirculation loop on the dry well. The simulations performed with the new model show that the changes made improve the prediction of the phenomenology involved during transients and accidents. (Author)

  8. Participation of the ININ in the activities of radioactive waste management of the Laguna Verde Central; Participacion del ININ en las actividades de gestion de desechos radiactivos de la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Medrano L, M.; Rodriguez C, C.; Linares R, D. [ININ, Gerencia Subsede Sureste (Mexico); Ramirez G, R.; Zarate M, N. [Central Laguna Verde, CFE (Mexico)]. e-mail: maam@nuclear.inin.mx

    2006-07-01

    From the beginning of the operation of the Laguna Verde Central (CLV) the National Institute of Nuclear Research (ININ) has come supporting the CLV in the activities of administration of the humid and dry radioactive waste generated by the operation of the two units of the CLV, from the elaboration of procedures to the temporary storage in site, the implementation of a program of minimization and segregation of dry solid wastes, until the classification of the lots of humid waste and bulk dry wastes. In this work the description of the management activities of radioactive wastes carried out by the ININ in the facilities of the CLV to the date is presented, as well as some actions that they are had drifted in the future near, among those that it stands out the determination of the total alpha activity in humid samples by means of scintillation analysis. (Author)

  9. Estimation of requirements of eolic energy equivalent to the electric generation of the Laguna Verde nuclear power plant; Estimacion de requerimientos de energia eolica equivalente a la generacion electrica de la Central Nucleoelectrica de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Garcia V, M.A.; Hernandez M, I.A. [Facultad de Ingenieria, Division de Ingenieria Electrica, UNAM, 04510 Mexico D.F. (Mexico)]. E-mail: maiki27@yahoo.com; Martin del Campo M, C. [Facultad de Ingenieria, Laboratorio de Analisis en Ingenieria de Reactores Nucleares, UNAM, Paseo Cuauhnahuac 8532, 62550 Jiutepec, Morelos (Mexico)

    2004-07-01

    The advantages are presented that have the nuclear and eolic energy as for their low environmental impact and to the human health. An exercise is presented in the one that is supposed that the electric power generated by the Laguna Verde Nuclear Power plant (CNLV), with capacity of 1365 M W, it should be produced by eolic energy when in the years 2020 and 2025 the units 1 and 2 of the CNLV reach its useful life and be moved away. It is calculated the number of aero generators that would produce the electric power average yearly of the CNLV, that which is equal to install eolic parks with capacity of 2758 M W, without considering that it will also be invested in systems of back generation to produce electricity when the aero generators stops for lack of wind. (Author)

  10. New recommendations of the ICRP and the ALARA program of the Nuclear power plant of Laguna Verde; Nuevas recomendaciones del ICRP y el programa ALARA de la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Padilla C, I [Comision Federal de Electricidad, Central Laguna Verde (Mexico)

    1991-07-01

    In view of the events happened in it finishes it decade, in the nuclear environment, it is necessary that any he/she practices that it involves exhibition to the radiation, real or potential, be detailed and systematically analyzed by the light of the current knowledge, capitalizing the generated experience. They think about three fundamental aspects in the campaign of radiological cultivation: 1. New methods of evaluation of equivalent dose. 2. Limit of individual dose, base of the change and control implications, and 3. Analysis philosophies and the application of the system of dose limitation. The program ALARA of the Laguna Verde Central from its installation in 1987 observes and it implements actions trending to optimize it practice of situation of potential and planned exhibition with the purpose of fulfilling the commitment settled down in the declaration of political of this program.

  11. Turbine model for the Laguna Verde nucleo electric central based in the RELAP code; Modelo de turbina para la Central nucleoelectrica de Laguna Verde basado en el codigo RELAP

    Energy Technology Data Exchange (ETDEWEB)

    Cortes M, F.S.; Ramos P, J.C.; Salazar S, E.; Chavez M, C. [Facultad de Ingenieria, Division de Estudios de Posgrado, Grupo de Ingenieria Nuclear, UNAM (Mexico)]. e-mail: cchavez2@cableonline.com.mx

    2003-07-01

    The Nuclear Power stations as Laguna Verde occupy at the present time a place every time but important as non pollutant alternative, economic and trusty to generate electricity. It is for it that the Group of Nuclear Engineering of the Engineering Faculty (GrlNFI) of the National Autonomous University of Mexico (UNAM) it develops investigation projects applied to Nuclear Centrals. One of the projects in process is the development of a Classroom simulator, which it can configures to consent to diverse models of nuclear systems with training purposes in normal operation, or, to consent to specialized nuclear codes for the analysis of transitory events and have a severe accident. This work describes the development, implementation and it proves of a simplified model of the Main turbine to be integrated to the group of models of the Classroom simulator. It is part of the current effort of GrlNFI guided to obtain a representation of all the dynamic models necessary to simulate the Plant Balance of the Laguna Verde Central. It is included the development of the unfolding graphic which represent the modeling of the Main turbine, and of the control interface that allows the user to manipulate in simple way, direct and interactive this device during the training or the analysis. With this work it is wanted to contribute to the training of new technicians and to support the operation personnel of the Centrals. Also, the developed infrastructure is guided to contribute in the design and analysis of new Nuclear Power stations with the contribution of new computational tools for the visualization, simulation and process control. (Author)

  12. Upgrade the intervention levels derived for water and foods, to be include in the PERE 607 procedure the external radiological emergency plan in the Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Llado Castillo, R.; Aguilar Pacheco, R.

    1998-01-01

    The work shows the results obtained in the upgrade the intervention levels derived for water and foods, to be include in the PERE 607 procedure the external radiological emergency plan in the Laguna Verde nuclear power plant

  13. Options for the ultimate storage of low and medium level radioactive wastes produced at Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Emeterio, Miguel

    1991-01-01

    The devoted time and still to be expend in prepare, execute and teach permanent and safe solutions to the problem of the evaluation of radioactive wastes reflects the political, economic and environmental importance with respect to public health and safety invested in this task, as well as, its technological challenges. In the case of Laguna Verde nuclear power plant, its low and medium level radioactive wastes are stored in the beginning in a temporal store with a capacity of 2000 m 3 sufficient to four years of normal operation; according to what it is necessary to select one of different ways of waste storage. Different technologies has been evaluated and the preliminary conclusion is that for Mexico the more feasible way to store radioactive wastes is in tumulus (Author)

  14. Estimation of requirements of eolic energy equivalent to the electric generation of the Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Garcia V, M.A.; Hernandez M, I.A.; Martin del Campo M, C.

    2004-01-01

    The advantages are presented that have the nuclear and eolic energy as for their low environmental impact and to the human health. An exercise is presented in the one that is supposed that the electric power generated by the Laguna Verde Nuclear Power plant (CNLV), with capacity of 1365 M W, it should be produced by eolic energy when in the years 2020 and 2025 the units 1 and 2 of the CNLV reach its useful life and be moved away. It is calculated the number of aero generators that would produce the electric power average yearly of the CNLV, that which is equal to install eolic parks with capacity of 2758 M W, without considering that it will also be invested in systems of back generation to produce electricity when the aero generators stops for lack of wind. (Author)

  15. Evaluation of radwaste minimization program of dry and wet active waste in the Laguna Verde Nuclear Power Plant

    International Nuclear Information System (INIS)

    Luna-Garza, Hector

    2001-01-01

    A growing rate of radwaste volume production combined with an increase of both, costs and associated dose involved in its treatment and disposition processes have created a serious problem to the Laguna Verde Nuclear Power Plant (BWR, two Units, 682 Mwe each) in Mexico. Due the lack of a Final Repository in the country, the solution in the short or long terms relies on the success of a continuous and aggressive minimization program mainly based on modifications and upgrades applied to these processes. Technical and administrative strategies adopted by LVNPP for the reduction of Liquid Effluents and Dry and Wet Active Waste in the next three years are described. Based on the results of the LVNPP current radwaste process systems, an estimated accumulation of 11,502 m 3 by the year 2035 will exceed the actual on-site storage capacity. If the strategies succeed, this production would fall to an expected manageable volume of 4067 m 3 . (author)

  16. New recommendations of the ICRP and the ALARA program of the Nuclear power plant of Laguna Verde

    International Nuclear Information System (INIS)

    Padilla C, I.

    1991-01-01

    In view of the events happened in it finishes it decade, in the nuclear environment, it is necessary that any he/she practices that it involves exhibition to the radiation, real or potential, be detailed and systematically analyzed by the light of the current knowledge, capitalizing the generated experience. They think about three fundamental aspects in the campaign of radiological cultivation: 1. New methods of evaluation of equivalent dose. 2. Limit of individual dose, base of the change and control implications, and 3. Analysis philosophies and the application of the system of dose limitation. The program ALARA of the Laguna Verde Central from its installation in 1987 observes and it implements actions trending to optimize it practice of situation of potential and planned exhibition with the purpose of fulfilling the commitment settled down in the declaration of political of this program

  17. Evaluation of the reduction of boron-10 in the control rods in the BWR of the Laguna Verde Central, through steady state calculations

    International Nuclear Information System (INIS)

    Montes T, J.L.; Perusquia, R.; Hernandez, J.L.; Ramirez S, J.R.

    2003-01-01

    One of the more important aspects related with the safety and economy in the operation of a nuclear power reactor, it is without a doubt the control of the reactivity. During the normal operation of a reactor of boiling water (BWR-Boiling Water Reactor), the control of the reactivity in the nucleus it is strongly determined by the efficiency of the control rods. In the case of the Laguna Verde Nuclear power station (CNLV) the nucleus of the reactors has 109 control rods grouped in 4 sets. The CNLV at the moment uses the CCC method (Control Cell Core) in the design of the cycle. With this method only the A2 group is used for the control of the reactivity at full power. With the purpose of quantifying the effect of the decrease of the burnable poison (B 4 C) of the control rods and in particular to the effect due to the postulated lost of 10% of Boron 10, it was carried out a series of calculations of the nucleus in stationary state by means of the system of HELIOS/CM-PRESTO codes. In this work the main derived results of these 3D simulations(three dimensions) of the reactors of the CNLV are presented. It was analyzed the one behavior of the infinite neutron multiplication factor (K infinite ), at fuel assemble cell level used in an equilibrium cycle for the CNLV. It was also analyzed the effect in the shutdown margin (ShutDown Margin- SDM) in cold condition CZP (Cold Zero Power). Its are also included those results of the ARI cases (All Rods In) and SRO (Strong Rod Out). From the cases in condition HFP (Hot Full Power) the behavior of the effective multiplication factor (K eff ) is presented. (Author)

  18. Generation of the ECP database (ECP01.DAT) of the cycle 1 of the Unit 1 of Laguna Verde with burnt of 1377 MWD/MT; Generacion de la base ECP (ECP01.DAT) del ciclo 1 de la Unidad 1 de Laguna Verde con quemado de 1377 MWD/MT

    Energy Technology Data Exchange (ETDEWEB)

    Perusquia C, R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1992-10-15

    In order to carrying out a comparison among the results provided by the Program of Estimate of the ECP Critical Position and the Shutdown/Startup produced in the Cycle 1 of the Unit 1 of Laguna Verde, it was generated the base of the ECP program, following the outlines settled down in the Procedure 'Generation of ECP Database for Laguna Verde' (IT.SN/DFR-074). Next the data sheets filled when being generated the ECP01.DAT database with a burnt of 1377 MWD/MT are provided. In the report IT.SN/DFR-079 'Adjustment and Preliminary Evaluation of the Predictions of Criticity of the ECP Program with Reported Data of the Cycle 1 of the Unit 1 of Laguna Verde', the results of the comparison among those estimates of the ECP program using the ECP01.DAT database with the real data of the Cycle 1 of the Unit 1 of Laguna Verde are presented. (Author)

  19. Modernization of the Electric Power Systems (transformers, rods and switches) in the Laguna Verde Nuclear Power Plant (Mexico); Modernizacion de los Sistemas Electricos de Potencia (Transformadores de Principales, Interruptor de Generacion, Barras de Fase Aislada) de la Central Nuclear de Laguna Verde (Mexico)

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Solarzano, J. J.; Gabaldon Martin, M. A.; Pallisa Nunez, J.; Florez Ordeonez, A.; Fernandez Corbeira, A.; Prieto Diez, I.

    2010-07-01

    Description of the changes made in the Electric Power Systems as a part of the power increase project in the Laguna Verde Nuclear Power Plant (Mexico). The main electrical changes to make, besides the turbo group, are the main generation transformers, the isolated rods and the generation switch.

  20. Analysis of the evolution of reactivity of the event at 24/01/1995 of the BWR U-1 of Laguna Verde

    International Nuclear Information System (INIS)

    Ruiz E, J.A.; Blazquez M, J.

    2003-01-01

    In this work it is looked for, to calculate the reactivity starting from the measures of the one nuclear detection system denominated by their initials in English 'APRM' (Average Power Range Monitor) of the oscillatory event of the unit 1 of the nuclear power station of Laguna Verde happened the 24/01/1995. The reference signal consists of 3589 points taken every 0.2 seconds before the reactor operator carried out the cut of the same one. It is tried to give answer to queries like: When the event really began?, How distinguishing the stable part of the unstable? Which could be the way of predicting it?. The analysis is developed applying the call 'inverse method', with the purpose of interpreting the power response, having a mean of obtaining the information about the changes of reactivity that were given in the transitory one and to look their relationship with the actions taken by the operator. A comparison of the variation of the signal of reactivity with basic statistical variables with the purpose of trying of to find a mechanism for early detection of the instability is included. (Author)

  1. Simulation of the turbine trip of Unit 1 of the Laguna Verde nuclear power plant using the code Simulate-3K

    International Nuclear Information System (INIS)

    Alegria A, A.; Filio L, C.; Ortiz V, J.

    2017-09-01

    In order to compare the results obtained from the model developed in the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) with the code Simulate-3K (S3K) with respect to those reported by the process computer of the Central (SIIP), the simulation of the turbine trip transient was carried out, caused by the firing of the main generator, the low differential pressure of oil of its seals and the automatic Scram of Unit 1 of the Laguna Verde nuclear power plant, at 87% of power nominal during the operation cycle 16. Since the reactor was brought to a safe stop due to Scram, was enough to simulate 20 seconds to observe the maximum increase in pressure with S3K. In this work, the following parameters are shown and compared: the neutron flux, the thermal power, the pressure in the dome, the flow at the entrance to the core, the steam flow that leaves the vessel and the minimal critical power ratio (MCPR). The neutron flux of the average power range monitors of the nuclear power plant was compared with the S3K detectors model. Finally, the MCPR was calculated with a different correlation to that of the fuel supplier and its deviation from its safety limit was determined. In conclusion, the results obtained show the current state of the model for the simulation of reactivity transients and the opportunity areas to consolidate this tool in support of the process of licensing refueling in the CNSNS. (Author)

  2. Range of the radiation monitor for the rigid vent of primary containment during normal and emergency operation for a BWR-5 in Laguna Verde

    International Nuclear Information System (INIS)

    Tijerina S, F.; Pozos S, A. M.; Cabrera U, S.; Mata A, J. A.; Sandoval V, S.; Ovando C, R.; Vargas A, A.; Gallardo R, I.; Cruz G, M.; Amador C, C.

    2014-10-01

    The earthquake followed by a tsunami, happened in March, 2011 in the coasts of oriental Japan, caused damages in the nuclear power plants 1 at 4 of Fukushima Daiichi leading to damage of the fuel in three of the reactors and to the radiation liberation to the exterior. As consequence of those events, the regulations requires that the power plants with Primary Containment type Mark I and II evaluate to have a system of rigid vent with a monitoring equipment of radiation effluents. The present work covers the rigid vent of diameter 12 of the Primary Containment, type Mark-II, of nuclear power plant of Laguna Verde in conditions of severe accident and normal operation, low regime of Extended Power Up rate (EPU - 2317 MWt), using the codes MAAP3B, MICROSHILED 5.05 and the Bardach Black Boxes methodology. As a result the measurement range of the radiation monitor that is required for monitoring the gassy liberation to the atmosphere was determined. The conclusion is that the superior limit of the range of the radiation meter during a Severe Accident is of 8.55 E + 05 R/h (8.55 E + 08 m R/h) and the superior limit in normal operation of 1.412 E-11 at 2.540 E-7 R/h (1.412 E-14 at 2.540 E-10 m R/h). (Author)

  3. Procedure of generation of the ECP database for Laguna Verde; Procedimiento de generacion de base de datos ECP para Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Perusquia C, R [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1992-09-15

    This procedure will be used by the personnel of the Discipline of Nuclear Analysis of the Reactor of CFE to execute PRESTO with the purpose of generating the base for the Estimate of the Position of critical bars during the start up (ECP Database). (Author)

  4. Tritium in liquid phase in a BWR-5 like Laguna Verde; Tritio en fase liquida en un BWR-5 como Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Tijerina S, F.; Vargas A, A.; Cardenas J, J., E-mail: francisco.tijerina@cfe.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Subgerencia de Ingenieria, Carretera Veracruz-Medellin Km 7.5, Veracruz (Mexico)

    2011-11-15

    In boiling water reactors (BWR), the tritium (H{sub 3}) takes place mainly as a result of ternary fissions in the nuclear reactors, of those which 75% are in gaseous form and 25% in liquid form. In the liquid phase, the tritium is transported to the pipes of the primary coolant toward condensed tanks or tanks of drainage excesses of radioactive equipment, located in external areas of a BWR, as well as to the processes of radioactive wastes to be able to be directed to the liquid effluents. For that reason, is necessary to know the possible routes of the transport and processes of the tritium in a BWR to control this radioisotope in the site of the event of leaks in equipment s and buried pipes, avoiding that emigrates toward underground flowing and an impact to the environment and to the people in general. (Author)

  5. Analysis of the preliminary trajectory of emergency venting of the nuclear power plant of Laguna Verde using RELAP5; Analisis de la trayectoria preliminar del venteo de emergencia de la Central Laguna Verde mediante RELAP5

    Energy Technology Data Exchange (ETDEWEB)

    Cecenas F, M.; Jimenez S, R.; Ovando C, R. [Instituto Nacional de Electricidad y Energias Limpias, Reforma No. 113, Col. Palmira, 42490 Cuernavaca, Morelos (Mexico); Tijerina S, F.; Tapia M, R. N., E-mail: mcf@iie.org.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Subgerencia de Ingenieria, Carretera Veracruz-Medellin Km. 7.5, 94271 Veracruz (Mexico)

    2016-09-15

    For a commercial nuclear plant, the availability of a vent line to the atmosphere is an improvement to achieve the prevention and mitigation of the consequences of a severe accident. The importance of this system received greater attention after the Fukushima accident in 2011. Subsequently, in 2012 and 2013, the United States Nuclear Regulatory Commission issued documents stating that the venting must be able to dislodge 1% of the rated thermal power of the core without over pressurizing the primary container. To analyze the venting of the nuclear power plant of Laguna Verde, the line and the primary container are modeled using the thermo-hydraulic code RELAP5, simulating a release of 1% of the nominal licensed power to the container in the form of saturated steam. The vent has no problem to evacuate the energy and manages to keep the container without exceeding its design limit, and the highest percentage of thermal power that can channel the vent to the outside is approximately 3%. A sensitivity analysis increasing the diameter of the line to 14 inches allows increasing in 10% the percentage of power that can be vented to the outside without problem for the containment. (Author)

  6. NucleoRed - Computerized system for increasing the effectiveness of the technical administrative conduct of the Laguna Verde Central; NucleoRed - Sistema computarizado para incrementar la efectividad de la gestion tecnico-administrativa de la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Luna D, J. [Central Nucleoelectrica Laguna Verde, Carretera cardel-Nautla Km. 42.5 Veracruz (Mexico)]. e-mail: jluna@cfe.gob.mx

    2003-07-01

    The on-line systems for the management of the Laguna Verde Central (CLV) have had the challenge to evolve from the PC's of first generation until emigrate to the new Internet technologies, so that they allow to the diverse work groups to have the computer tool that allows them to gather the necessary data and to carry out efficiently the analysis of their results. To confront the previous challenge, in the CLV it has been developed and implemented the Nucleo Red that is an on-line system with the objective of providing in it lines strategic information for the Technician-administrative management of the plant in the nuclear context. The Nucleo Red is the computational tool that reflects the technical administrative processes implemented by personnel of the different Operative departments, it seeks to cooperate to the reliable and efficient operation of the first nucleo electric central of Mexico, with technology and Mexican personnel the one which already it had received international recognitions. The perspective of this computer system is to continue inside the process of continuous improvement and that although it was designed for a nucleo electric plant it can also be taken to the conventional plants of generation of electric power, so that this technology can be taken advantage of in other non nuclear facilities. The objective of the present work, is to show the new modules that have been developed in the Nucleo Red, its operation in general, and the benefits that it presents its use. (Author)

  7. Experiences in the implementation of the Coaching project in the nuclear power plant of Laguna Verde (NPP-L V); Experiencias en la implementacion del proyecto Coaching en la Central Nucleoelectrica Laguna Verde (CNLV)

    Energy Technology Data Exchange (ETDEWEB)

    Mendez M, H. I., E-mail: hugo.mendez01@cfe.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Departamento del Centro de Entrenamiento, Carretera Cardel-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2012-10-15

    This document has the purpose of to share acquired experiences during the implementation of the Coaching project focused the training of supervisors and directive personnel of the nuclear power plant of Laguna Verde (NPP-L V). Derived of the improvement areas identified by the supervisor organization of the nuclear power stations WANO (World Association Nuclear of Operators) and of the auto-evaluations realized by the expert personnel of the same power station that based on external experiences carried out through the Benchmarking (comparison with other power stations) they have reflected the necessity to activate a training process in Coaching with a practical focus toward the directive and supervisor personnel in the power station. By means of the observation of the personnel's acting so much in the control rooms like in different areas, three focus areas have been identified for the training in Coaching, these are the personnel's motivation, the organizational communication so much in vertical form as horizontal and the perception of confidence lack among directive, supervisors, operators and technicians. The plan focused in the abilities training of Coaching with practical sense was development, supported with an evaluation of 360 grades as tool of competitions development through a computer application e-Coaching. The use of application and Coaching following techniques facilitated the conformation of the practical focus, same that are of continuous use starting from the training of the supervisor and directive personnel. (Author)

  8. Analysis of a natural draught tower in the circulation seawater system of nuclear power plant of Laguna Verde; Analisis de una torre de tiro natural en el sistema de agua de circulacion de mar de la central nucleoelectrica Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Tijerina S, F.; Vargas A, A. [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Subgerencia de Ingenieria, Carretera Veracruz-Medellin Km. 7.5, Veracruz (Mexico)], e-mail: francisco.tijerina@cfe.gob.mx

    2009-10-15

    The analysis of a natural draught tower in open circuit for the cooling system of seawater circulation on the nuclear power plant of Laguna Verde, it is based on conditions of 2027 MWt and 2317 MWt, where the flows of circulation water system hardly vary and whose purpose will be, to cool the seawater circulation. The circulation water system is used as heat drain in main condenser of turbo generator to condense the nuclear vapor. The annual average temperature in the seawater at present is of 26 C to the entrance to circulation water system and it is vary in accordance with the time of year. The mean temperature of leaving of circulation water system to the sea is of 41 C. Having a cooling tower to reduce the entrance temperature to the circulation water system, it improves the efficiency of thermal transfer in condenser, it improves the vacuum in condenser giving more operative margin to avoid condenser losses by air entrances and nuclear power plant shutdowns, as well as for to improve the efficiency of operative balance of nuclear power plant, also it prevents the impact in thermal transfer efficiency in condenser by the climatic change. (Author)

  9. Structuring a risk-informed and performance-based process for optimization of regulation for Laguna Verde NPP

    International Nuclear Information System (INIS)

    Rodriguez-Hernandez, A.

    2001-01-01

    This work describes the plan for a process to incorporate into the regulatory activities the risk information derived from probabilistic risk assessments, as well as information generated by the periodic evaluation of the Maintenance Rule (MR, 10CFR50.65). The current status of the Laguna Verde NPP (LVNPP) risk analysis, PSA Level 1, allows determining in a reliable way the accident scenarios and the involved systems having significant impact on safety. The determination of system's risk significance allows carrying out a prioritization of safety issues to be evaluated and inspected; for example, operational events, changes to technical specifications, design modifications, inspection priorities, etc. In addition, complementary and basic information are the results generated by the performance monitoring of structures, systems and components (SSCs) under the scope of the MR. The SSCs performance trends are indicatives to focus evaluation and inspection activities on important issues. Then, with the reportability in short periods the performance evaluations of SSCs and the incorporation of a process of risk management, the evaluation and inspection activities will be directed to those risk significant systems showing degraded performance. Therefore, based on systems performance results and risk information, it is feasible to have certain flexibility or a better balance between the regulatory requirements. Inside this process, a consensus is needed with the utility to establish quality attributes for the plant-specific PSA, as well as the rules to be followed in the use of this tool and the kind of information to be reported for MR results. (author)

  10. NucleoRed - Computerized system for increasing the effectiveness of the technical administrative conduct of the Laguna Verde Central

    International Nuclear Information System (INIS)

    Luna D, J.

    2003-01-01

    The on-line systems for the management of the Laguna Verde Central (CLV) have had the challenge to evolve from the PC's of first generation until emigrate to the new Internet technologies, so that they allow to the diverse work groups to have the computer tool that allows them to gather the necessary data and to carry out efficiently the analysis of their results. To confront the previous challenge, in the CLV it has been developed and implemented the Nucleo Red that is an on-line system with the objective of providing in it lines strategic information for the Technician-administrative management of the plant in the nuclear context. The Nucleo Red is the computational tool that reflects the technical administrative processes implemented by personnel of the different Operative departments, it seeks to cooperate to the reliable and efficient operation of the first nucleo electric central of Mexico, with technology and Mexican personnel the one which already it had received international recognitions. The perspective of this computer system is to continue inside the process of continuous improvement and that although it was designed for a nucleo electric plant it can also be taken to the conventional plants of generation of electric power, so that this technology can be taken advantage of in other non nuclear facilities. The objective of the present work, is to show the new modules that have been developed in the Nucleo Red, its operation in general, and the benefits that it presents its use. (Author)

  11. Experiences in the implementation of the Coaching project in the nuclear power plant of Laguna Verde (NPP-L V)

    International Nuclear Information System (INIS)

    Mendez M, H. I.

    2012-10-01

    This document has the purpose of to share acquired experiences during the implementation of the Coaching project focused the training of supervisors and directive personnel of the nuclear power plant of Laguna Verde (NPP-L V). Derived of the improvement areas identified by the supervisor organization of the nuclear power stations WANO (World Association Nuclear of Operators) and of the auto-evaluations realized by the expert personnel of the same power station that based on external experiences carried out through the Benchmarking (comparison with other power stations) they have reflected the necessity to activate a training process in Coaching with a practical focus toward the directive and supervisor personnel in the power station. By means of the observation of the personnel's acting so much in the control rooms like in different areas, three focus areas have been identified for the training in Coaching, these are the personnel's motivation, the organizational communication so much in vertical form as horizontal and the perception of confidence lack among directive, supervisors, operators and technicians. The plan focused in the abilities training of Coaching with practical sense was development, supported with an evaluation of 360 grades as tool of competitions development through a computer application e-Coaching. The use of application and Coaching following techniques facilitated the conformation of the practical focus, same that are of continuous use starting from the training of the supervisor and directive personnel. (Author)

  12. Analysis of a natural draught tower in the circulation seawater system of nuclear power plant of Laguna Verde

    International Nuclear Information System (INIS)

    Tijerina S, F.; Vargas A, A.

    2009-10-01

    The analysis of a natural draught tower in open circuit for the cooling system of seawater circulation on the nuclear power plant of Laguna Verde, it is based on conditions of 2027 MWt and 2317 MWt, where the flows of circulation water system hardly vary and whose purpose will be, to cool the seawater circulation. The circulation water system is used as heat drain in main condenser of turbo generator to condense the nuclear vapor. The annual average temperature in the seawater at present is of 26 C to the entrance to circulation water system and it is vary in accordance with the time of year. The mean temperature of leaving of circulation water system to the sea is of 41 C. Having a cooling tower to reduce the entrance temperature to the circulation water system, it improves the efficiency of thermal transfer in condenser, it improves the vacuum in condenser giving more operative margin to avoid condenser losses by air entrances and nuclear power plant shutdowns, as well as for to improve the efficiency of operative balance of nuclear power plant, also it prevents the impact in thermal transfer efficiency in condenser by the climatic change. (Author)

  13. Analysis of the preliminary trajectory of emergency venting of the nuclear power plant of Laguna Verde using RELAP5

    International Nuclear Information System (INIS)

    Cecenas F, M.; Jimenez S, R.; Ovando C, R.; Tijerina S, F.; Tapia M, R. N.

    2016-09-01

    For a commercial nuclear plant, the availability of a vent line to the atmosphere is an improvement to achieve the prevention and mitigation of the consequences of a severe accident. The importance of this system received greater attention after the Fukushima accident in 2011. Subsequently, in 2012 and 2013, the United States Nuclear Regulatory Commission issued documents stating that the venting must be able to dislodge 1% of the rated thermal power of the core without over pressurizing the primary container. To analyze the venting of the nuclear power plant of Laguna Verde, the line and the primary container are modeled using the thermo-hydraulic code RELAP5, simulating a release of 1% of the nominal licensed power to the container in the form of saturated steam. The vent has no problem to evacuate the energy and manages to keep the container without exceeding its design limit, and the highest percentage of thermal power that can channel the vent to the outside is approximately 3%. A sensitivity analysis increasing the diameter of the line to 14 inches allows increasing in 10% the percentage of power that can be vented to the outside without problem for the containment. (Author)

  14. Simulation of the turbine trip of Unit 1 of the Laguna Verde nuclear power plant using the code Simulate-3K; Simulacion del disparo de turbina de la Unidad 1 de la central nuclear Laguna Verde empleando el codigo Simulate-3K

    Energy Technology Data Exchange (ETDEWEB)

    Alegria A, A. [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan 779, Col. Narvarte, 03020 Ciudad de Mexico (Mexico); Filio L, C. [IPN, Escuela Superior de Fisica y Matematicas, Av. IPN s/n, 07738 Ciudad de Mexico (Mexico); Ortiz V, J., E-mail: aalegria@cnsns.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2017-09-15

    In order to compare the results obtained from the model developed in the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) with the code Simulate-3K (S3K) with respect to those reported by the process computer of the Central (SIIP), the simulation of the turbine trip transient was carried out, caused by the firing of the main generator, the low differential pressure of oil of its seals and the automatic Scram of Unit 1 of the Laguna Verde nuclear power plant, at 87% of power nominal during the operation cycle 16. Since the reactor was brought to a safe stop due to Scram, was enough to simulate 20 seconds to observe the maximum increase in pressure with S3K. In this work, the following parameters are shown and compared: the neutron flux, the thermal power, the pressure in the dome, the flow at the entrance to the core, the steam flow that leaves the vessel and the minimal critical power ratio (MCPR). The neutron flux of the average power range monitors of the nuclear power plant was compared with the S3K detectors model. Finally, the MCPR was calculated with a different correlation to that of the fuel supplier and its deviation from its safety limit was determined. In conclusion, the results obtained show the current state of the model for the simulation of reactivity transients and the opportunity areas to consolidate this tool in support of the process of licensing refueling in the CNSNS. (Author)

  15. Analysis of the evolution of reactivity of the event at 24/01/1995 of the BWR U-1 of Laguna Verde; Analisis de la evolucion de la reactividad del evento del 24/01/1995 del BWR U-1 de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz E, J.A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Blazquez M, J. [CIEMAT, 28040 Madrid (Spain)]. e-mail: jare@nuclear.inin.mx

    2003-07-01

    In this work it is looked for, to calculate the reactivity starting from the measures of the one nuclear detection system denominated by their initials in English 'APRM' (Average Power Range Monitor) of the oscillatory event of the unit 1 of the nuclear power station of Laguna Verde happened the 24/01/1995. The reference signal consists of 3589 points taken every 0.2 seconds before the reactor operator carried out the cut of the same one. It is tried to give answer to queries like: When the event really began?, How distinguishing the stable part of the unstable? Which could be the way of predicting it?. The analysis is developed applying the call 'inverse method', with the purpose of interpreting the power response, having a mean of obtaining the information about the changes of reactivity that were given in the transitory one and to look their relationship with the actions taken by the operator. A comparison of the variation of the signal of reactivity with basic statistical variables with the purpose of trying of to find a mechanism for early detection of the instability is included. (Author)

  16. Four stops of fuel reloading with duration of less of 30 days in the Laguna Verde Central; Cuatro paradas de recarga de combustible con duracion de menos de 30 dias en la central laguna verde

    Energy Technology Data Exchange (ETDEWEB)

    Lozano L, A. [CFE, Central Laguna Verde, Planeacion, Veracruz (Mexico)]. e-mail: agustin.lozano@cfe.gob.mx

    2008-07-01

    The Laguna Verde Central having established as mission 'With maximum priority in the safety, to generate electricity by nuclear means with competitive quality and cost, sustained in our personnel's continuous overcoming and deep respect to the environment' and respecting our values (safety, responsibility by results, professional integrity, continuous improvement, team work, excellence in the performance, quality of service, protection to the environment its thought about our strategic objectives of the power station being born by this way one of them that it is the improvement program 'reduction of reloading times' looking for to be improves every day comparing us with the best plants of the world effectiveness all the processes in the power station that allowed us to measure our performance with the same parameters that settle down at international level as its are nuclear safety, industrial safety, radiological safety, capacity factor, readiness factor, cleaning of the power station attachment to procedures, attention to the detail and certainly to be competitive in the economic aspect. After analyzing the performance record of the power station, evaluating our technical, economic capacity, the location of the installation besides revising the international experiences was defined that one of the concepts that impact considerably so much to the capacity factors and readiness besides the dose and production cost is the duration of the reloading periods, for this reason work strategies were elaborated to be able to reach our goals of reloading days in less than 30 days, here are formed the carried out actions that they made us complete the four last reloading in less than 30 days. (Author)

  17. Three stops of fuel reloading with length of less 30 days in the Laguna Verde Central; Tres paradas de recarga de combustible con duracion de menos de 30 dias en la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Lozano L, A. [Comision Federal de Electricidad, Central Laguna Verde, Subgerencia General de Operacion Planeacion, Veracruz (Mexico)]. e-mail: agustin.lozano@cfe.gob.mx

    2007-07-01

    The Laguna Verde Central having established as mission 'With maximum priority in the safety, to generate electricity by nuclear means with quality and cost competitive, sustained in our personnel's continuous overcoming and deep respect to the environment' and respecting our values (safety, responsibility by results, professional integrity, continuous improving, team working, excellence in the acting, quality of service, protection to the environment) they thought about our strategic objectives of the power station being born this way one of them that it is the program of improvement 'Reduction of reload times' looking for to be improves every day comparing us with the best plants in the world efficient all the processes in the power station that allowed us to measure our acting with the same parameters that settle down at international level like they are nuclear safety, industrial safety, radiological safety, capacity factor, readiness factor, cleaning of the power station attachment to procedures, attention to the detail and certainly to be competitive in the economic aspect. After analyzing the acting record of the power station, evaluating our technical capacity, economic, the location of the installation besides revising the international experiences it was defined that one of the concepts that impact considerably so much to the capacity and readiness factors besides the dose and production cost is the duration of the reload periods, for this reason they were elaborated work strategies to be able to reach our goal of reload days considered in being able to carry out them in less than 30 days, here the actions carried out that they made us complete the three last reloads in less than 30 days are captured. (Author)

  18. Simulation of overpressure events with a Laguna Verde model for the RELAP code to conditions of extended power up rate; Simulacion de eventos de sobrepresion con un modelo de Laguna Verde para el codigo RELAP a condiciones de aumento de potencia extendido

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez H, A.; Araiza M, E.; Fuentes M, L.; Ortiz V, J., E-mail: andres.rodriguez@inin.gob.mx [ININ, Departamento de Sistemas Nucleares, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2012-10-15

    In this work the main results of the simulation of overpressure events are presented using a model of the nuclear power plant of Laguna Verde developed for the RELAP/SCDAPSIM code. As starting point we have the conformation of a Laguna Verde model that represents a stationary state to similar conditions to the operation of the power station with Extended Power Up rate (EPU). The transitory of simulated pressure are compared with those documented in the Final Safety Analysis Report of Laguna Verde (FSAR). The results of the turbine shot transitory with and without by-pass of the main turbine are showed, and the event of closes of all the valves of main vapor isolation. A preliminary simulation was made and with base in the results some adjustments were made for the operation with EPU, taking into account the Operation Technical Specifications of the power station. The results of the final simulations were compared and analyzed with the content in the FSAR. The response of the power station to the transitory, reflected in the model for RELAP, was satisfactory. Finally, comments about the improvement of the model are included, for example, the response time of the protection and mitigation systems of the power station. (Author)

  19. Validation of a new version of software for monitoring the core of nuclear power plant of Laguna Verde Unit 2, at the end of Cycle 10

    International Nuclear Information System (INIS)

    Hernandez, G.; Calleros, G.; Mata, F.

    2009-10-01

    This work shows the differences observed in thermal limits established in the technical specifications of operation, among the new software, installed at the end of Cycle 10 of Unit 2 of nuclear power plant of Laguna Verde, and the old software that was installed from the beginning of the cycle. The methodology allowed to validate the new software during the coast down stage, before finishing the cycle, for what could be used as tool during the shutdown of Unit 2 at the end of Cycle 10. (Author)

  20. Four stops of fuel reloading with duration of less of 30 days in the Laguna Verde Central

    International Nuclear Information System (INIS)

    Lozano L, A.

    2008-01-01

    The Laguna Verde Central having established as mission 'With maximum priority in the safety, to generate electricity by nuclear means with competitive quality and cost, sustained in our personnel's continuous overcoming and deep respect to the environment' and respecting our values (safety, responsibility by results, professional integrity, continuous improvement, team work, excellence in the performance, quality of service, protection to the environment its thought about our strategic objectives of the power station being born by this way one of them that it is the improvement program 'reduction of reloading times' looking for to be improves every day comparing us with the best plants of the world effectiveness all the processes in the power station that allowed us to measure our performance with the same parameters that settle down at international level as its are nuclear safety, industrial safety, radiological safety, capacity factor, readiness factor, cleaning of the power station attachment to procedures, attention to the detail and certainly to be competitive in the economic aspect. After analyzing the performance record of the power station, evaluating our technical, economic capacity, the location of the installation besides revising the international experiences was defined that one of the concepts that impact considerably so much to the capacity factors and readiness besides the dose and production cost is the duration of the reloading periods, for this reason work strategies were elaborated to be able to reach our goals of reloading days in less than 30 days, here are formed the carried out actions that they made us complete the four last reloading in less than 30 days. (Author)

  1. Effects evaluation of artificial aging by temperature and gamma radiation on cables for Laguna Verde nuclear power plant (LVNPP)

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez C, R. M.; Bonifacio M, J.; Garcia H, E. E.; Loperena Z, J. A. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Garcia M, C., E-mail: raulmario.vazquez@inin.gob.m [CFE, Central Nuclear Laguna Verde, Km. 42.5 Carretera Cardel-Nautla, Veracruz (Mexico)

    2010-10-15

    A set of tests has been carried out at the Equipment Qualification Laboratory at National Institute of Nuclear Research to perform accelerated aging up to 60 years under temperature and gamma radiation environment for electrical cables. The results obtained from such tests are the base line data for comparison to with the current cable conditions at the plant. This work is intended for establishing the cable aging management program for the Laguna Verde nuclear power plant (LVNPP). For such purpose, the Institute has prepared methodologies and procedures to apply condition monitoring techniques in accelerated aging tests on samples of new cables drawn from the LVNPP warehouse. The condition indicators of the material selected for condition monitoring and the aging management process of cables were: Elongation at Break (EAB) and Oxidation Induction Time (OIT). A cable aging management program includes activities for cable selection, determination of condition indicators of the cable materials (EAB, OIT, Ind enter), accelerated aging of cable samples at the laboratory, analysis of maintenance history, operational experience of the plant and analysis of the environmental and service conditions (temperature and gamma radiation), as well as the establishment of a condition monitoring plan for cables in the plant. Two cable model samples were thermally aged and gamma irradiated with doses corresponding to differential operational periods. EAB and OIT values of cable insulating material (ethylene propylene and cross linked polyethylene) were obtained. It was found that the EAB and OIT data correlation is very closed, and it could be applied to infer values that are not possible to measure directly at the plant and be used for cable aging evaluation and remaining life time determination. (Author)

  2. Training in fundamentals of radiological coverage in Laguna Verde NPP; Entrenamiento de fundamentos de coberturas radiologicas en la CLV

    Energy Technology Data Exchange (ETDEWEB)

    Lara H, M. A., E-mail: marcolarah@gmail.com [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Carretera Cardel-Nautla Km. 42.5, Alto Lucero, Veracruz (Mexico)

    2014-10-15

    In 2010, the Institute of Nuclear Power Operations (INPO) celebrates the Knowledge Transfer and Retention Workshop, an event where nuclear regulators and operators presented the strategies that various NPP to worldwide were implemented to mitigate the consequences of this generational change and take advantage of it, the trend in the presented works was the same: the generational change occurs in a faster way that the transfer of knowledge, the future was already here and many NPP had not been adequately prepared to train its nuclear technicians and engineers in the tasks demanded by the industry of them, so in addition to preparing these workers to forced marches was necessary to establish strategies to retain at more experienced staff in the industry. The Laguna Verde NPP has not been exempt to this process; the preparation of personnel squares to replace those that reaching retirement age in the Comision Federal de Electricidad (CFE) has become extensive in the last five years, sometimes leading to have personnel covering functions without an alternate to the next lower position, the cause? Not enough staff. In the specific case of radiation protection (Rp) the time required for obtaining the status of Rp technician according to the ANSI/ANS 3.1 standard is 2 years, one of the tasks that most occupies part of these two years is training in radiological coverage, this training requires a mix of knowledge and experience, recently one of the concepts used for training in Rp is the evaluation and management of the radiological risk, topic that is considered in this technical work. (Author)

  3. Tritium in liquid phase in a BWR-5 like Laguna Verde

    International Nuclear Information System (INIS)

    Tijerina S, F.; Vargas A, A.; Cardenas J, J.

    2011-11-01

    In boiling water reactors (BWR), the tritium (H 3 ) takes place mainly as a result of ternary fissions in the nuclear reactors, of those which 75% are in gaseous form and 25% in liquid form. In the liquid phase, the tritium is transported to the pipes of the primary coolant toward condensed tanks or tanks of drainage excesses of radioactive equipment, located in external areas of a BWR, as well as to the processes of radioactive wastes to be able to be directed to the liquid effluents. For that reason, is necessary to know the possible routes of the transport and processes of the tritium in a BWR to control this radioisotope in the site of the event of leaks in equipment s and buried pipes, avoiding that emigrates toward underground flowing and an impact to the environment and to the people in general. (Author)

  4. CARACTERIZACIÓN ESTRUCTURAL DEL MANGLAR EN EL ESTERO PALO VERDE, LAGUNA DE CUYUTLÁN, COLIMA

    Directory of Open Access Journals (Sweden)

    Citlalli P. Téllez-García

    2012-01-01

    Full Text Available En el Estero Palo Verde, ubicado en el vaso IV de la Laguna de Cuyutlán, estado de Colima, se establecieron 48 unidades de muestreo (UM en tres rodales de mangle: 10 UM en rodal monoespecífico de Laguncularia racemosa, 25 UM en rodal monoespecífico de Rhizophora mangle y 13 UM en rodal mixto de L. racemosa-R. mangle. Se registró altura del dosel, diámetro del tronco, densidad de adultos y de repoblación, también se calculó área basal y volumen de madera. Los resultados indicaron que la densidad, área basal y volumen, para la categoría diamétrica (CD de 5 cm fueron significativamente diferentes (P < 0.05 entre los rodales monoespecíficos de R. mangle (2,500 árboles•ha-1, 4.2 m2•ha-1 y 22 m3•ha-1, respectivamente y L. racemosa (700 árboles•ha-1, 1.9 m2•ha-1 y 10 m3•ha-1, respectivamente. En las CD de 20 a 30 cm, el área basal fue significativamente mayor (P < 0.05 en el rodal monoespecífico de L. racemosa (1.6 - 3.8 m2•ha-1 que en el mixto de L. racemosa-R. mangle (0.5 - 2.5 m2•ha-1. La repoblación natural fue más abundante en el rodal de R. mangle (138 a 270 individuos•ha-1 que en el de L. racemosa (70 a 80 individuos•ha-1. Los valores estructurales mayores se alcanzaron para altura del dosel (10 m en el rodal de L. racemosa; para diámetro (40 cm y área basal (14.1 m2•ha-1 en el rodal de L. racemosa-R. mangle; y para repoblación natural (624 individuos•ha-1 en el rodal de R. mangle.

  5. Nuclear fuel management and transients analysis in Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    De Loera De Haro, M.A.; Alvarez Gasca, J.

    1991-01-01

    Nuclear fuel management transient analysis are the set of activities which determine the load and reload of nuclear fuel inside the reactor, with the aim of getting the maximum performance in fuel burn up and heat remotion, without have an effect in the station safety. Nuclear fuel management and transient analysis has its basis on high precision quantitative analysis methodologies by means of simulation of nuclear and physical phenomena occurring both in normal and abnormal operation of nuclear power plants. On account of complexity of simulations and the required precision, those are carry out using codes type 'best estimate'. For the use of this tools it is necessary a deep knowledge of simulated nuclear and physical phenomena, as well as the used mathematical models and the numerical methods used. If different, the simulation results will be notably different actual processes owing to the use of models out of validity range, or incorrect calculations in the input parameters. On account of complexity of simulations and the required precision, those are carry out using codes type 'best estimate'. For the use of this tools it is necessary a deep knowledge of simulated nuclear and physical phenomena, as well as the used mathematical models and the numerical methods used. If different, the simulation results will be notably different actual processes owing to the use of models out of validity range, or incorrect calculations in the input parameters

  6. Proposal of the visual inspection of the integrity of the storage cells of spent fuel from the nuclear power plant of Laguna Verde

    International Nuclear Information System (INIS)

    Gonzalez M, J. L.; Rivero G, T.; Merino C, F. J.; Santander C, L. E.

    2015-09-01

    As part of the evaluation of the structural integrity of the components of nuclear plants, particularly those applying for life extension is necessary to carry out inspections and nondestructive testing to determine the state meet. In many cases these activities are carried out in areas with high levels of radiation and contamination difficult to access, so that are required to use equipment or robotic systems operated remotely. Among others, the frames and cells of the storage pools for spent fuel are structures subject to a program of tests and inspections, and become relevant because the nuclear power plant of Laguna Verde (NPP-LV) is processing the license to extend the operational life of its reactors. Of non-destructive testing can be used to verify the physical condition of the frames and storage cells, is the remote visual inspection which is a test that allows determine the physical integrity of the components by one or more video cameras designed to applications in underwater environments with radiation, and are used to identify and locate adverse conditions such as ampoules, protuberances, pitting, cracks, stains or buckling, which could affect the three main functions for which the store components are designed: to maintain the physical integrity of spent fuels, store them properly guaranteeing their free insertion and removal, and ensure that the store as a whole meets the criticality criteria that k eff is less than 0.95 throughout the life of the plant. This paper describes a proposal to carry out the visual inspection of the storage cells of spent fuel from the NPP-LV using a probe including one or more video cameras along with your recorder, and its corresponding control program. It is noted that due to the obtained results, the nuclear power plant personnel can make decisions regarding remedial actions or applying complementary methods to verify that the cells and frames have not lost their physical integrity, or in particular that the cover

  7. Validation of a new version of software for monitoring the core of nuclear power plant of Laguna Verde Unit 2, at the end of Cycle 10; Validacion de una nueva version del software para monitoreo del nucleo de la Central Laguna Verde Unidad 2, al final del Ciclo 10

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, G.; Calleros, G.; Mata, F. [Comision Federal de Electricidad, Central Nucleoelectrica de Laguna Verde, Carretera Cardel-Nautla Km 42.5, Veracruz (Mexico)], e-mail: gabriel.hernandez05@cfe.gob.mx

    2009-10-15

    This work shows the differences observed in thermal limits established in the technical specifications of operation, among the new software, installed at the end of Cycle 10 of Unit 2 of nuclear power plant of Laguna Verde, and the old software that was installed from the beginning of the cycle. The methodology allowed to validate the new software during the coast down stage, before finishing the cycle, for what could be used as tool during the shutdown of Unit 2 at the end of Cycle 10. (Author)

  8. Revision of documents guide to obtain the renovation of licence of the nuclear power plant of Laguna Verde, Units I and II

    International Nuclear Information System (INIS)

    Jarvio C, G.; Fernandez S, G.

    2008-01-01

    Unquestionably the renovation of license of the nuclear power plants , it this converting in a promising option to be able to gather in sure, reliable form and economic those requests about future energy in the countries with facilities of this type. This work it analyzes four documents guide and their application for the determination of the renovation of it licenses in nuclear plants that will serve of base for their aplication in the Nuclear Power Plant of Laguna Verde Units I and 2. The four documents in question are: the one Inform Generic of Learned Lessons on the Aging (NUREG - 1801), the Standard Revision Plan for the Renovation of License (NUREG - 1800), the Regulatory Guide for Renovation of License (GR-1.188), and the NEI 95-10, developed by the Institute of Nuclear Energy that is an Industrial Guide to Implement the Requirements of the 1OCFR Part 54-the Rule of Renovation of It licenses. (Author)

  9. Methodology of aging management in structures, systems and components of a nuclear power plant and its application to a pilot program in Laguna Verde

    International Nuclear Information System (INIS)

    Jarvio C, G.; Fernandez S, G.

    2009-10-01

    From its origin the nuclear power plants confront the effects of time and of environment, giving as result the aging of its structures, systems and components. In this document the general process is described for the establishment of Aging Management Program developed by IAEA. Following the program methodology is guaranteed that a nuclear power plant manages the aging effects appropriately and to make decisions for its solution, assuring the characteristic functions of structures, systems and components of same nuclear power plant. On the other hand, the implantation of an aging management program constitutes the base for development of a licence renovation program, like it can be the specific case of the Central Laguna Verde Units 1 and 2. (Author)

  10. Simulation of the steady state of the Laguna Verde Nuclear power station at full power (1931 MWt and 2027 Mwt) with the SCDAPSIM code

    International Nuclear Information System (INIS)

    Amador G, R.; Nunez C, A.; Mateos, E. del A.

    2001-01-01

    This document describes two models developed for the Laguna Verde Nuclear Power Station (LVNPP) using SCDAPSIM computer code. These models represent the LVNPP in normal operation with a nominal power of 1931 MWt and power uprate conditions of 2027 MWt. The steady states obtained by means of these models comply with the criteria established by the ANSI/ANS-3.5-1985 for nuclear power plant simulators. This criteria has been applied to the models of the LVNPP developed by CNSNS in want of some international accepted criteria for ''Best Estimation'' computer codes. These models will be the bases to carry out studies of validation of the own models as well as the analysis of diverse scenarios that evolve to a severe accident. (Author)

  11. Development of the stationary state and simulation of an accident severe stage type station blackout with the MELCOR code version 1.8.6 for the nuclear power plant of Laguna Verde

    International Nuclear Information System (INIS)

    Mugica R, C. A.; Godinez S, V.

    2011-11-01

    Considering the events happened since the 11 March of 2011, in Japan, where an earthquake of 9.1 grades Ritcher of intensity and a later tsunami impacted in an important way the operation of a nuclear power plant located in the Fukushima, Japan; damaging and disabling their cooling systems and injection of emergency water due to the total loss of electric power (commonly denominated Station Blackout), is eminent the analysis of this stage type that took to the nuclear power plant to conditions of damage to the core and explosions generation by hydrogen concentrations in the reactor building. In this work an analysis of a stage type station blackout is presented, using the model of the nuclear power plant of Laguna Verde starting of the stationary state. The analysis is carried out using the MELCOR code (Methods for Estimation of Leakages and Consequences of Releases) version 1.8.6 whose purpose is to model the accidents progression for light water reactors. The obtained results are qualitatively similar to the events observed in the Fukushima nuclear power plant even though limitations exist to achieve a precise simulation of the events happened in Japan, such as the information flow of the chronology of the operator actions, as well as of the characteristic design of the power plant, volumes in cavities and rooms, water/cooling inventories, interconnected systems and their own emergency procedures or guides for the administration of severe accidents among others. (Author)

  12. Search for neutrino oscillations at the palo verde nuclear reactors

    Science.gov (United States)

    Boehm; Busenitz; Cook; Gratta; Henrikson; Kornis; Lawrence; Lee; McKinny; Miller; Novikov; Piepke; Ritchie; Tracy; Vogel; Wang; Wolf

    2000-04-24

    We report on the initial results from a measurement of the antineutrino flux and spectrum at a distance of about 800 m from the three reactors of the Palo Verde Nuclear Generating Station using a segmented gadolinium-loaded scintillation detector. We find that the antineutrino flux agrees with that predicted in the absence of oscillations excluding at 90% C.L. nu;(e)-nu;(x) oscillations with Deltam(2)>1.12x10(-3) eV(2) for maximal mixing and sin (2)2straight theta>0.21 for large Deltam(2). Our results support the conclusion that the atmospheric neutrino oscillations observed by Super-Kamiokande do not involve nu(e).

  13. Application of new control technology during the maintenance of equipment in the Laguna Verde nuclear power plant; Aplicacion de nueva tecnologia de control durante el mantenimiento de equipos en la CLV

    Energy Technology Data Exchange (ETDEWEB)

    Ojeda R, M. A. [CFE, Central Laguna Verde, Subgerencia General de Operacion, Veracruz (Mexico)]. e-mail: mario.ojeda@cfe.gob.mx

    2008-07-01

    In the nuclear power plant of Laguna Verde, in normal operation and recharges are carried out activities of preventive maintenance and corrective to different equipment, due to the one displacement of radioactive materials from the vessel of the reactor until the one system of vapor, different radiation levels are generated (from low until very high) in the circuits of vapor and water, the particles can be incrusted on those interior surfaces of the pipes and equipment, creating this way a potential risk of contamination and exhibition during the maintenance of equipment. To help to optimize the dose to the personnel the use of new technology the has been implemented which besides contributing an absolute control of the work, it offers bigger comfort to the one worker during the development of their work, also contributing a supervision more effective of the same one. Using the captured and processed information of the work developed you can use for the personnel's capacitation and feedback of the work for the continuous improvement of the same one. During a reduction of programmed power and normal operation are carried out maintenance correctives and specific works to preserve the readiness and ability of the equipment and with this to maintain the security of the nuclear power plant. The development of the theme it is showing the advances and commitments of personnel to take to excellence to the nuclear power plant of Laguna Verde showing to the obtained results of the dose and benefits of 2 works carried out in the nuclear power plant where tools ALARA were applied as well as the use of the new technology (Video Equipment of Tele dosimetry and Audio 'VETA') in works carried out in the building of purification level 10.15, change and cuts of filter of the prefilters of system G16, as well as,the retirement and transfer for its decay of High Integrity Container (HIC) of the building of purification level -0.55 to the Temporary Warehouse in Site

  14. Licensing process of the digital application: Nuclear measurement analysis and control power range neutron monitor (NUMAC-PRNM) system for their implementation in the Laguna Verde NPP unit 2

    International Nuclear Information System (INIS)

    Ledesma-Carrion, R.; Hernandez-Cortes, A.

    1998-01-01

    This paper describe the licensing process performed by the Mexican Regulatory Commission (CNSNS) for the NUclear Measurement Analysis and Control-Power Range Neutron Monitor (NUMAC-PRNM) system, which sends trip signals to the Reactor Protection System (RPS), and has been implemented in the Laguna Verde Nuclear Power Plant Unit (LVNPP-U2) before its first fuel loading. The review and approval process was performed with the advise role of the United States of America Nuclear Regulatory Commission (USNRC): the regulatory frame applied includes the Code of Federal Regulation, some Regulatory Guides and some Industrial Standards. The evaluation covered topics related with the software, hardware and firmware specifications, design, tests, training, maintenance and operational experience. After the revision of these topics, the NUMAC-PRNM was approved through the CNSNS Safety Evaluation Report (SER) and then installed in the LVNPP-U2. This paper include a description of the regulatory requirements to this digital application, the safety concerns involved, the compliance to these requirements by the utility and the results of the CNSNS evaluation, mentioning the experience acquired during the process and the method used to perform the evaluation. Additionally, the interface between the designer-vendor, the utility and the regulatory body during the licensing process is commented. Finally, the conclusion is presented, taking into account the operational experience of the NUMAC applications implemented in the LVNPP. It also gives the future regulatory tasks related to the assessment of digital performance equipment and upgrades. (author)

  15. Proposal of the visual inspection of the integrity of the storage cells of spent fuel from the nuclear power plant of Laguna Verde; Propuesta para la inspeccion visual de la integridad de las celdas de almacenamiento de combustible gastado de la Central Laguna Verde (CLV)

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, J. L.; Rivero G, T.; Merino C, F. J. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Santander C, L. E., E-mail: francisco.merino@inin.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Carretera Veracruz-Medellin Km 7.5, Col. Dos Bocas, 94271 Medellin, Veracruz (Mexico)

    2015-09-15

    As part of the evaluation of the structural integrity of the components of nuclear plants, particularly those applying for life extension is necessary to carry out inspections and nondestructive testing to determine the state meet. In many cases these activities are carried out in areas with high levels of radiation and contamination difficult to access, so that are required to use equipment or robotic systems operated remotely. Among others, the frames and cells of the storage pools for spent fuel are structures subject to a program of tests and inspections, and become relevant because the nuclear power plant of Laguna Verde (NPP-LV) is processing the license to extend the operational life of its reactors. Of non-destructive testing can be used to verify the physical condition of the frames and storage cells, is the remote visual inspection which is a test that allows determine the physical integrity of the components by one or more video cameras designed to applications in underwater environments with radiation, and are used to identify and locate adverse conditions such as ampoules, protuberances, pitting, cracks, stains or buckling, which could affect the three main functions for which the store components are designed: to maintain the physical integrity of spent fuels, store them properly guaranteeing their free insertion and removal, and ensure that the store as a whole meets the criticality criteria that k{sub eff} is less than 0.95 throughout the life of the plant. This paper describes a proposal to carry out the visual inspection of the storage cells of spent fuel from the NPP-LV using a probe including one or more video cameras along with your recorder, and its corresponding control program. It is noted that due to the obtained results, the nuclear power plant personnel can make decisions regarding remedial actions or applying complementary methods to verify that the cells and frames have not lost their physical integrity, or in particular that the cover

  16. Revision of documents guide to obtain the renovation of licence of the nuclear power plant of Laguna Verde, Units I and II; Revision de documentos guia para obtener la renovacion de licencia de la Central Nuclear Laguna Verde Unidades 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Jarvio C, G. [ININ 52750 La Marquesa, Estado de Mexico (Mexico); Fernandez S, G. [CFE, Gerencia de Centrales Nucleoelectricas, Subgerencia de Ingenieria, Carretera Veracruz-Medellin s/n (Km. 7.5), Dos Bocas, 54270 Veracruz (Mexico)]. e-mail: giarvio@yahoo.com.mx

    2008-07-01

    Unquestionably the renovation of license of the nuclear power plants , it this converting in a promising option to be able to gather in sure, reliable form and economic those requests about future energy in the countries with facilities of this type. This work it analyzes four documents guide and their application for the determination of the renovation of it licenses in nuclear plants that will serve of base for their aplication in the Nuclear Power Plant of Laguna Verde Units I and 2. The four documents in question are: the one Inform Generic of Learned Lessons on the Aging (NUREG - 1801), the Standard Revision Plan for the Renovation of License (NUREG - 1800), the Regulatory Guide for Renovation of License (GR-1.188), and the NEI 95-10, developed by the Institute of Nuclear Energy that is an Industrial Guide to Implement the Requirements of the 1OCFR Part 54-the Rule of Renovation of It licenses. (Author)

  17. Simulation of the steady state of the Laguna Verde Nuclear power station at full power (1931 MWt and 2027 Mwt) with the SCDAPSIM code; Simulacion del estado estacionario de la Central Nucleoelectrica de Laguna Verde a plena potencia (1931 MWt y 2027 MWt) con el codigo SCDAPSIM

    Energy Technology Data Exchange (ETDEWEB)

    Amador G, R.; Nunez C, A.; Mateos, E. del A. [Comision Nacional de Seguridad Nuclear y Salvaguardias, Mexico D.F. (Mexico)

    2001-07-01

    This document describes two models developed for the Laguna Verde Nuclear Power Station (LVNPP) using SCDAPSIM computer code. These models represent the LVNPP in normal operation with a nominal power of 1931 MWt and power uprate conditions of 2027 MWt. The steady states obtained by means of these models comply with the criteria established by the ANSI/ANS-3.5-1985 for nuclear power plant simulators. This criteria has been applied to the models of the LVNPP developed by CNSNS in want of some international accepted criteria for ''Best Estimation'' computer codes. These models will be the bases to carry out studies of validation of the own models as well as the analysis of diverse scenarios that evolve to a severe accident. (Author)

  18. Innovation, creative ideas to attend the challenges of the Central Laguna Verde for the period 2011-2015 due to new 100% of power

    International Nuclear Information System (INIS)

    Rivera C, A.

    2011-11-01

    For the nuclear power plant of Laguna Verde (CLV) is an opportunity to present to the nuclear community in Mexico the improvement areas and challenges for the period 2011-2015, now that has been concluded the phase of starting tests of the CLV modernization, with an increment of power of 20% that represents a new generation of electrical power of 815 M We per hour in the 2 Units, with these new challenges the strategic planning 2011 at 2015 take relevance to give guide to the innovation, with new ideas of improvement to the processes, human resources and leadership, with the purpose of maintaining reliable all the equipment s and process systems by means of the use of strengths, opportunities, vulnerabilities and threats analysis, in order to make strategies that aid to generate competitive advantages for the production of electric power in Mexico, using privileged information that contain the database of the improvement systems, like are the programs of corrective action, of human acting, of external operational experience, of auto-evaluation and of benchmarking that is the referential comparison with other similar power stations. At present, in the general management of operation exist the training by coaching to grow in the formation of the half commands and line supervisors, reinforcing the wanted behaviors, the abilities of the technicians, and the orientation in deficient performances in the search of the operational excellence. (Author)

  19. Quality studies of the energy in the electric net of the gathering warehouse of reusable parts and contaminate oils of the nuclear power plant Laguna Verde

    International Nuclear Information System (INIS)

    Tijerina S, F.; Vargas A, A.; Cardenas J, J.

    2012-10-01

    In the industry exist the high costs by faults of electronic and electric equipment s, due to during the design process, installation, tests and operation of these equipment s, is not had appropriate detection equipment to carry out quality studies of the energy. These studies give an important support to know that occurs in an electric net, the cause of the anomalous behavior of the equipment s and this way to avoid the expensive faults carrying out necessary engineering adaptations in an electric net. The elements of the electricity that are determined are the tension, current and frequency that are inside acceptable operational parameters that facilitate the operation and constant operation of the equipment s, free of interruptions and failures. The application of the quality studies of the energy is growing little by little in Mexico for the problems solution in the equipment s. This field is also developing new techniques and technologies integrated in the equipment s for its monitoring detection and protection. The present work offers the results of the first Quality Study of the Energy in the nuclear power plant of Laguna Verde to solve the problem in the gathering warehouse of reusable parts and contaminate oils, in which the failure of the two radiation monitors of the gassy effluent of ventilation HVAC of the warehouse took place. (Author)

  20. Changes in reactivity and in the margins to thermal limits by the inclusion of control rods of advanced type in the Laguna Verde Power plant

    International Nuclear Information System (INIS)

    Hernandez, J.L.; Perusquia, R.; Montes, J.L.; Ortiz, J.J.; Ramirez, J.R.

    2004-01-01

    The obtained results are presented when simulating with CM-PRESTO code the cycle 10 of the unit 1 of the Laguna Verde Central, using two advanced types of control bars, besides the originally loaded ones. The two advanced types, to those that are denominated 1AV and 2AV in this work, are of different design, however both have in some place of the bar, a section with hafnium like neutron absorber material. They thought about three different scenarios, in the first one, used as reference, is simulated the cycle 10 using the original control bars, while in the other two cases the advanced types are used. The values of the reactivity were compared and of some margins to the thermal limits obtained when using the bars of advanced type, with those obtained in the case in that alone they are considered those original bars. It was found that in condition of power both advanced types present bigger absorber power of neutrons that the original bars, being quantified in average this bigger power in 0.22 pcm/notch for the type 1AV and in 0.51 pcm/notch for the type 2AV. The affectation of the margins to the observed thermal limits is minimum. (Author)

  1. Simulations of the design basis accident at conditions of power increase and the o transient of MSIV at overpressure conditions of the Laguna Verde Power Station

    International Nuclear Information System (INIS)

    Araiza M, E.; Nunez C, A.

    2001-01-01

    This document presents the analysis of the simulation of the loss of coolant accident at uprate power conditions, that is 2027 MWt (105% of the current rated power of 1931MWt). This power was reached allowing an increase in the turbine steam flow rate without changing the steam dome pressure value at its rated conditions (1020 psiaJ. There are also presented the results of the simulation of the main steam isolation va/ve transient at overpressure conditions 1065 psia and 1067 MWt), for Laguna Verde Nuclear Power Station. Both simulations were performed with the best estimate computer code TRA C BF1. The results obtained in the loss of coolant accident show that the emergency core coolant systems can recover the water level in the core before fuel temperature increases excessively, and that the peak pressure reached in the drywell is always below its design pressure. Therefore it is concluded that the integrity of the containment is not challenged during a loss of coolant accident at uprate power conditions.The analysis of the main steam isolation valve transients at overpressure conditions, and the analysis of the particular cases of the failure of one to six safety relief valves to open, show that the vessel peak pressures are below the design pressure and have no significant effect on vessel integrity. (Author)

  2. Scenarios simulation of severe accident type small loss of coolant (Loca), with the code MELCOR version 2.1 for the nuclear power plant of Laguna Verde

    International Nuclear Information System (INIS)

    Cardenas V, J.; Mugica R, C. A.; Godinez S, V.

    2013-10-01

    In this work was carried out the analysis of two scenarios of the accident type with loss of coolant in a recirculation loop for a break with smaller ares to 0.1 ft 2 (4.6 cm 2 ), which is classified according to their size like small Loca. The first simulated scenario was a small Loca without action of the emergency coolant injection systems, and the second was a small Loca with only the available system LPCS. This design base accident was taken into account for its relevance with regard to the damage to the core and the hydrogen generation. Was also observed and analyzed the response of the action of the ECCS that depend of the loss of coolant reason and this in turn depends of the size and type of the pipe break. The specified scenarios were simulated by means of the use of MELCOR model for the nuclear power plant of Laguna Verde that has the Comision Nacional de Seguridad Nuclear y Salvaguardias. (Author)

  3. Approach to criticality in cold core of the Unit 1 of the cycle 10 of the Laguna Verde power plant with control rods similar in design to the original ones and the advanced ones

    International Nuclear Information System (INIS)

    Perusquia, R.; Ramirez, J.R.; Ortiz, J.J.; Hernandez, J.L.; Montes, J.L.

    2004-01-01

    In the Laguna Verde power plant (CLV) worn out control bars have been replacing for control rods of advanced design. At the moment of the 109 rods of similar design to the original of the Unit 1 of the CLV, 14 of them have been substituted with two types of different advanced control rods. The same as the original rods the advanced rods use boron carbide as control element for neutrons, but additionally they use hafnium, to achieve a longer useful half life. The rods of similar design to the original are homogeneous axially on the other hand the advanced presenting several zones. In principle the advanced rods were designed to be neutronically compatible to the original rods. However the differences in the design and of constituents assumed to consider a different performance during the operation. Since the one numbers of advanced bars is growing with the number of cycles of the CLV reactor has requested to the National Institute of Nuclear Research (ININ) to evaluate in detailed form the performance of the control rods. Previously the calculations and analysis of cycle design that that were carried out assumed that control rods should be of similar design as the original. Using the HELIOS/CM-LENDS system, the effect of the inclusion of advanced rods was analyzed in the approximation of the criticality in cold (20 C) in the cycle 10 of the Unit 1. Four scenarios were poposed, where the type of the rod of substitution control is varied. The value of reactivity was calculated for the rods similar in design to the original and for the advanced one. By comparison of these values, it was found that the value of reactivity of the control rods of the advanced design was superior to the value for rods similar to the original ones by 7.6% for one of the advanced designs and of 13.6% for the other one. (Author)

  4. A mathematical model; Un modelo matematico para el comportamiento de la radiosensibilidad medida con la viabilidad huevo-adulto de Drosophila melanogaster y D. simulans de Laguna Verde, Veracruz

    Energy Technology Data Exchange (ETDEWEB)

    Castillo M, J.A.; Pimentel P, A.E. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    This work presents the results to define the adult egg viability behavior (VHA) of two species, Drosophila melanogaster and D. simulans obtained with the mathematical model proposed, as well as the respective curves. The data are the VHA result of both species coming from the vicinity of the Laguna Verde Nuclear Power plant (CNLV) comprise a 10 years collect period starting from 1987 until 1997. Each collect includes four series of data which are the VHA result obtained after treatment with 0, 4, 6 and 8 Gy of gamma rays. (Author)

  5. Closure simulation of the MSIV of Unit 1 of the Laguna Verde nuclear power plant using the Simulate 3K code

    International Nuclear Information System (INIS)

    Alegria A, A.

    2015-09-01

    In this paper the simulation of closure transient of all main steam isolation valves (MSIV) was performed with the Simulate-3K (S-3K) code for the Unit 1 of the Laguna Verde nuclear power plant (NPP-LV), which operates to thermal power of 2317 MWt, corresponding to the cycle 15 of operation. The set points for the performance of systems correspond to those set out in transient analysis: 3 seconds for the closure of all MSIV; the start of Scram when 121% of the neutron flux is reached, respect from baseline before the transient; the opening by peer of safety relief valves (SRV) in relief mode when the set point of the pressure is reached, the shoot of the feedwater flow seconds after the start of closing of the MSIV and the shoot of the recirculation water pumps when the pressure is reached in the dome of 1048 psig. The simulation time was of 57 seconds, with the top 50 to reach the steady state, from which the closure of all MSIV starts. In this paper the behavior of the pressure in the dome are analyzed, thermal power, neutron flux, the collapsed water level, the flow at the entrance of core, the steam flow coming out of vessel and the flow through of the SRV; the fuel temperature, the minimal critical power ratio, the readings in the instrumentation systems and reactivities. Instrumentation systems were implemented to analyze the neutron flux, these consist of 96 local power range monitors (LPRM) located in different radial and axial positions of the core and 4 channels of average power range monitors, which grouped at 24 LPRM each one. LPRM response to the change of neutron flux in the center of the core, at different axial positions is also shown. Finally, the results show that the safety limit MCPR is not exceeded. (Author)

  6. SIMPRO, a practical tool for training the staff of Laguna Verde nuclear power plant; El SIMPRO, una herramienta practica para la capacitacion y entrenamiento del personal de la CNLV

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Valdez, Guillermo Omar; Gomez Camargo, Octavio; Castelo Cuevas, Luis; Vazquez Bustos, Jesus [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2012-06-22

    Laguna Verde Nuclear Power Plant (LVNPP) has implemented a real physical model, which represents several parts of a simplified version of its process. This development has proved to be very useful to improve the compliance with training programs and staff training maintenance in the different disciplines of engineering. Such programs are required by regulations and standards applicable for Nuclear Power Plants (NPP), so that the personnel working in these facilities can be able to respond on time to any contingency that might arise. This paper outlines the creation of the real physical model, how it is integrated and some of the practices that can be performed on this model. [Spanish] La Central Nucleoelectrica de Laguna Verde ha implementado un modelo fisico real que representa varias partes de una version simplificada de su proceso. Este desarrollo ha demostrado ser muy util para mejorar el cumplimiento de programas de adiestramiento, incluidos los del personal de mantenimiento, en diferentes disciplinas de ingenieria. Dichos programas son requeridos por las regulaciones y normas aplicables a las centrales nucleoelectricas, de manera que el personal que trabaja en estas instalaciones pueda ser capaz de responder oportunamente a cualquier contingencia que pudiera surgir. Este articulo describe la creacion del modelo fisico real, como se integra y algunas de las practicas que pueden llevarse a cabo con el.

  7. Quality studies of the energy in the electric net of the gathering warehouse of reusable parts and contaminate oils of the nuclear power plant Laguna Verde; Estudios de calidad de la energia en la red electrica del almacen de acopio de partes reusables y aceites contaminados (CCAC) de la Central Nuclear Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Tijerina S, F.; Vargas A, A.; Cardenas J, J., E-mail: francisco.tijerina@cfe.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Subgerencia de Ingenieria, Carretera Cardel-Nautla Km 42.5, Veracruz (Mexico)

    2012-10-15

    In the industry exist the high costs by faults of electronic and electric equipment s, due to during the design process, installation, tests and operation of these equipment s, is not had appropriate detection equipment to carry out quality studies of the energy. These studies give an important support to know that occurs in an electric net, the cause of the anomalous behavior of the equipment s and this way to avoid the expensive faults carrying out necessary engineering adaptations in an electric net. The elements of the electricity that are determined are the tension, current and frequency that are inside acceptable operational parameters that facilitate the operation and constant operation of the equipment s, free of interruptions and failures. The application of the quality studies of the energy is growing little by little in Mexico for the problems solution in the equipment s. This field is also developing new techniques and technologies integrated in the equipment s for its monitoring detection and protection. The present work offers the results of the first Quality Study of the Energy in the nuclear power plant of Laguna Verde to solve the problem in the gathering warehouse of reusable parts and contaminate oils, in which the failure of the two radiation monitors of the gassy effluent of ventilation HVAC of the warehouse took place. (Author)

  8. Simulations of the design basis accident at conditions of power increase and the o transient of MSIV at overpressure conditions of the Laguna Verde Power Station; Simulaciones del accidente base de diseno a condiciones de aumento de potencia y del transitorio de cierre de MSIV a condiciones de sobrepresion de la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Araiza M, E.; Nunez C, A. [Comision Nacional de Seguridad Nuclear y Salvaguardias, 03000 Mexico D.F. (Mexico)

    2001-07-01

    This document presents the analysis of the simulation of the loss of coolant accident at uprate power conditions, that is 2027 MWt (105% of the current rated power of 1931MWt). This power was reached allowing an increase in the turbine steam flow rate without changing the steam dome pressure value at its rated conditions (1020 psiaJ. There are also presented the results of the simulation of the main steam isolation va/ve transient at overpressure conditions 1065 psia and 1067 MWt), for Laguna Verde Nuclear Power Station. Both simulations were performed with the best estimate computer code TRA C BF1. The results obtained in the loss of coolant accident show that the emergency core coolant systems can recover the water level in the core before fuel temperature increases excessively, and that the peak pressure reached in the drywell is always below its design pressure. Therefore it is concluded that the integrity of the containment is not challenged during a loss of coolant accident at uprate power conditions.The analysis of the main steam isolation valve transients at overpressure conditions, and the analysis of the particular cases of the failure of one to six safety relief valves to open, show that the vessel peak pressures are below the design pressure and have no significant effect on vessel integrity. (Author)

  9. Innovation, creative ideas to attend the challenges of the Central Laguna Verde for the period 2011-2015 due to new 100% of power; Innovacion, ideas creativas para atender los retos y desafios del periodo de la Central Laguna Verde en 2011-2015 por el nuevo 100% de potencia

    Energy Technology Data Exchange (ETDEWEB)

    Rivera C, A., E-mail: arr99999@cfe.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Carretera Cardel-Nautla Km 42.5, Veracruz (Mexico)

    2011-11-15

    For the nuclear power plant of Laguna Verde (CLV) is an opportunity to present to the nuclear community in Mexico the improvement areas and challenges for the period 2011-2015, now that has been concluded the phase of starting tests of the CLV modernization, with an increment of power of 20% that represents a new generation of electrical power of 815 M We per hour in the 2 Units, with these new challenges the strategic planning 2011 at 2015 take relevance to give guide to the innovation, with new ideas of improvement to the processes, human resources and leadership, with the purpose of maintaining reliable all the equipment s and process systems by means of the use of strengths, opportunities, vulnerabilities and threats analysis, in order to make strategies that aid to generate competitive advantages for the production of electric power in Mexico, using privileged information that contain the database of the improvement systems, like are the programs of corrective action, of human acting, of external operational experience, of auto-evaluation and of benchmarking that is the referential comparison with other similar power stations. At present, in the general management of operation exist the training by coaching to grow in the formation of the half commands and line supervisors, reinforcing the wanted behaviors, the abilities of the technicians, and the orientation in deficient performances in the search of the operational excellence. (Author)

  10. Scenarios simulation of severe accident type small loss of coolant (Loca), with the code MELCOR version 2.1 for the nuclear power plant of Laguna Verde; Simulacion de escenarios de accidente severo tipo perdida de refrigerante (Loca) pequeno, con el codigo MELCOR version 2.1 para la central nucleo-electrica de Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas V, J.; Mugica R, C. A.; Godinez S, V., E-mail: Jaime.cardenas@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Jose Ma. Barragan No. 779, Col. Narvarte, 03020 Mexico D. F. (Mexico)

    2013-10-15

    In this work was carried out the analysis of two scenarios of the accident type with loss of coolant in a recirculation loop for a break with smaller ares to 0.1 ft{sup 2} (4.6 cm{sup 2}), which is classified according to their size like small Loca. The first simulated scenario was a small Loca without action of the emergency coolant injection systems, and the second was a small Loca with only the available system LPCS. This design base accident was taken into account for its relevance with regard to the damage to the core and the hydrogen generation. Was also observed and analyzed the response of the action of the ECCS that depend of the loss of coolant reason and this in turn depends of the size and type of the pipe break. The specified scenarios were simulated by means of the use of MELCOR model for the nuclear power plant of Laguna Verde that has the Comision Nacional de Seguridad Nuclear y Salvaguardias. (Author)

  11. Changes in reactivity and in the margins to thermal limits by the inclusion of control rods of advanced type in the Laguna Verde Power plant; Cambios en la reactividad y en los margenes a limites termicos por la inclusion de barras de control de tipo avanzado en la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, J.L.; Perusquia, R.; Montes, J.L.; Ortiz, J.J.; Ramirez, J.R. [ININ, Depto. de Sistemas Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)]. E-mail: jlhm@nuclear.inin.mx

    2004-07-01

    The obtained results are presented when simulating with CM-PRESTO code the cycle 10 of the unit 1 of the Laguna Verde Central, using two advanced types of control bars, besides the originally loaded ones. The two advanced types, to those that are denominated 1AV and 2AV in this work, are of different design, however both have in some place of the bar, a section with hafnium like neutron absorber material. They thought about three different scenarios, in the first one, used as reference, is simulated the cycle 10 using the original control bars, while in the other two cases the advanced types are used. The values of the reactivity were compared and of some margins to the thermal limits obtained when using the bars of advanced type, with those obtained in the case in that alone they are considered those original bars. It was found that in condition of power both advanced types present bigger absorber power of neutrons that the original bars, being quantified in average this bigger power in 0.22 pcm/notch for the type 1AV and in 0.51 pcm/notch for the type 2AV. The affectation of the margins to the observed thermal limits is minimum. (Author)

  12. Analysis of the noise of the jet pumps of the Unit 2 of the Laguna Verde nuclear power plant; Analisis de ruido de las bombas de chorro de la Unidad 2 de la Central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Castillo D, R.; Ortiz V, J.; Ruiz E, J.A. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Calleros M, G. [CFE, Central Nucleoelectrica de Laguna Verde, Alto Lucero, Veracruz (Mexico)]. E-mail: rcd@nuclear.inin-mx

    2004-07-01

    The use of the analysis of noise for the detection of badly functioning of the components of a BWR it is a powerful tool in the determination of abnormal conditions of operation, during the life of a nuclear plant of power. From the eighties, some nuclear reactors have presented problems related with the jet pumps and the knots of the recirculation. The Regulatory Commission of the United States, in the I E bulletin 80-07, recommended to carry out a periodic supervision of the pressure drop of the jet pumps, to prevent structural failures. In this work, methods of analysis of noise are used for the detection of abnormal conditions of operation of the jet pumps of a BWR. Signals are analysed to low and high frequency of pressure drop with the NOISE software that is in development. The obtained results show the behavior of the jet pumps of jet 6 and 11 before and after a partial blockade in their throats where the pump 6 return to their condition of previous operation and the pump 11 present a new fall of pressure, inside the limit them permissible of operation. The methodology of the analysis of noise demonstrated to be an useful tool for the badly functioning detection, and you could apply to create a database to supervise the dynamic behavior of the jet pumps of an BWR. (Author)

  13. Rehabilitation and modernization project of units 1 and 2 of Laguna Verde Nuclear Power Plant. A strengthening project to 120%. (2nd phase); Proyecto de rehabilitacion y modernizacion de las Unidades 1and 2 de la CNLV. Un proyecto de reponteciacion al 120% (2ª Fase)

    Energy Technology Data Exchange (ETDEWEB)

    Liebana, B.; Merino, A.; Garcia, J. L.; Gomez, M.; Martinez, I.; Ruiz, L.

    2010-07-01

    The power increase of the Laguna Verde Nuclear Power Plant is a project for the rehabilitation and modernization of the turbo and associated equipment to get an increase of its power and of its service life. The project scope includes the design, the engineering, the equipment supply, the installation, the testing and the commissioning. This article presents the work of the second phase.

  14. Analysis of the noise of the jet pumps of the Unit 2 of the Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Castillo D, R.; Ortiz V, J.; Ruiz E, J.A.; Calleros M, G.

    2004-01-01

    The use of the analysis of noise for the detection of badly functioning of the components of a BWR it is a powerful tool in the determination of abnormal conditions of operation, during the life of a nuclear plant of power. From the eighties, some nuclear reactors have presented problems related with the jet pumps and the knots of the recirculation. The Regulatory Commission of the United States, in the I E bulletin 80-07, recommended to carry out a periodic supervision of the pressure drop of the jet pumps, to prevent structural failures. In this work, methods of analysis of noise are used for the detection of abnormal conditions of operation of the jet pumps of a BWR. Signals are analysed to low and high frequency of pressure drop with the NOISE software that is in development. The obtained results show the behavior of the jet pumps of jet 6 and 11 before and after a partial blockade in their throats where the pump 6 return to their condition of previous operation and the pump 11 present a new fall of pressure, inside the limit them permissible of operation. The methodology of the analysis of noise demonstrated to be an useful tool for the badly functioning detection, and you could apply to create a database to supervise the dynamic behavior of the jet pumps of an BWR. (Author)

  15. Impact on the bar value in hot by the introduction of advanced control bars in the Unit 1 of the Laguna Verde Nuclear power plant; Impacto sobre el valor de barra en caliente por la introduccion de barras de control avanzadas en la U1 de la CNLV

    Energy Technology Data Exchange (ETDEWEB)

    Montes, J.L.; Perusquia, R.; Ortiz, J.J.; Hernandez, J.L.; Ramirez, J.R. [ININ, Carretera Mexico-Toluca Km. 36.5, 52045 Estado de Mexico (Mexico)]. e-mail: jlmt@nuclear.inin.mx

    2004-07-01

    In recent dates the Laguna Verde Nuclear Power station (CNLV) has acquired new designs of control bars, this new type of bars presents modifications important in their design. For what is important to analyze their performance inside those reactors of this nuclear power station. Presently work is shown the behavior of the nucleus of the reactor in hot condition (HFP) when three different types of control bar are used. The first of them corresponds the one that initially has been used in this power station and that we will call original. The second type of control bars, it corresponds to an advanced type and it is the first design different from the original and it corresponds to a bar design that it includes Hafnium (Hf) like one of their neutronic absorption characteristics. The third, denoted as 2AV, include besides the material of the second type new design characteristics, and it is the last finish bar type that it has been introduced in the operation of the reactors of the CNLV. With base in the studied cases is found that the bars 2AV have a total power value, 7.6 % bigger respect the bars 1AV; and in turn the bars 1AV, 6.1 % bigger with respect the ORG control bars. (Author)

  16. Closure simulation of the MSIV of Unit 1 of the Laguna Verde nuclear power plant using the Simulate 3K code; Simulacion del cierre de las MSIV de la Unidad 1 de la central nuclear Laguna Verde empleando el codigo Simulate-3K

    Energy Technology Data Exchange (ETDEWEB)

    Alegria A, A., E-mail: aalegria@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan 779, Col. Narvarte, 03020 Ciudad de Mexico (Mexico)

    2015-09-15

    In this paper the simulation of closure transient of all main steam isolation valves (MSIV) was performed with the Simulate-3K (S-3K) code for the Unit 1 of the Laguna Verde nuclear power plant (NPP-LV), which operates to thermal power of 2317 MWt, corresponding to the cycle 15 of operation. The set points for the performance of systems correspond to those set out in transient analysis: 3 seconds for the closure of all MSIV; the start of Scram when 121% of the neutron flux is reached, respect from baseline before the transient; the opening by peer of safety relief valves (SRV) in relief mode when the set point of the pressure is reached, the shoot of the feedwater flow seconds after the start of closing of the MSIV and the shoot of the recirculation water pumps when the pressure is reached in the dome of 1048 psig. The simulation time was of 57 seconds, with the top 50 to reach the steady state, from which the closure of all MSIV starts. In this paper the behavior of the pressure in the dome are analyzed, thermal power, neutron flux, the collapsed water level, the flow at the entrance of core, the steam flow coming out of vessel and the flow through of the SRV; the fuel temperature, the minimal critical power ratio, the readings in the instrumentation systems and reactivities. Instrumentation systems were implemented to analyze the neutron flux, these consist of 96 local power range monitors (LPRM) located in different radial and axial positions of the core and 4 channels of average power range monitors, which grouped at 24 LPRM each one. LPRM response to the change of neutron flux in the center of the core, at different axial positions is also shown. Finally, the results show that the safety limit MCPR is not exceeded. (Author)

  17. Remote handling and robotic inspections of Palo Verde reactor vessel internals

    International Nuclear Information System (INIS)

    Ryder, W.

    1998-01-01

    Remote visual examinations and handling evolutions in high radiation field environments have required the use of radiation tolerant video systems. These systems involve significant expense and potentially require large envelope deployment structures. Recent events at Palo Verde including Upper Guide Structure damage and Reactor Vessel In-Service Inspections have provided opportunities for research, design and utilization of alternative approaches. Most significant of these, utilization of CCD modules with high magnification capabilities, have produced higher quality viewing, reduced maintenance expenditures, and rapid deployment intervals. (orig.) [de

  18. Arrangement and statistics of storage containers of spent fuel for assemblies of the SFP of NPP-L V, Unit 1; Arreglo y estadistica de contenedores de almacenamiento de combustible gastado para los ensambles de la ACG de la Unidad 1 de la Central Nucleoelectrica Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Mijangos D, Z. E.; Vargas A, A. F.; Amador C, C., E-mail: zoedelfin@gmail.com [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Subgerencia de Ingenieria, Km 44.5 Carretera Cardel-Nautla, 91476 Laguna Verde, Alto Lucero, Veracruz (Mexico)

    2014-10-15

    This work presents the determination of assemblies of the spent fuel pool (SFP) of the nuclear power plant of Laguna Verde (NPP-L V) which are candidates to be assigned to storage containers of independent spent fuel, with the objective of liberating decay heat and to have more space in the SFP, for the store of retired assemblies of the reactors in future reloads of NPP-L V, besides that the removed assemblies of the SFP should be stored in specific containers to guarantee the physical safety of them, as well as the radiological protection to the population and the environment. The design of the containers considered in this work is to store a maximum of 69 assemblies; it has a thermal capacity of 26 kilowatts and allows storing assemblies with a minimum of 5 years of have been extracted of the reactor core. Is considered that in 2016 start the storage of the spent assemblies on the containers, the candidates assemblies to store cover from the first reload in 1991, until the assemblies deposited in the SFP in the 14 reload in 2010; therefore in 2016, such assemblies will have fulfilled with the criteria of 5 years of have been removed of the Reactor, also the 69 assemblies assigned to each container will have a resulting decay heat that does not exceed the thermal capacity of the container, but that in great percentage approximates to the same one, and this way to take full advantage of their storage capacity and thermal capacity for each container. This work also contains the arrangement to accommodate the assemblies in the containers; such arrangement is constituted by areas according to the decay heat of each assembly. (Author)

  19. Experience with reactor power cutback system at Palo Verde nuclear generating station

    International Nuclear Information System (INIS)

    Chari, D.R.; Rec, J.R.; Simoni, L.P.; Eimar, R.L.; Sowers, G.W.

    1987-01-01

    Palo Verde Nuclear Generating Station (PVNGS) is a three unit site which illustrates System 80 nuclear steam supply system (NSSS) design. The System 80 NSSS is the Combustion Engineering (C-E) standard design rated at 3817 Mwth. PVNGS Units 1 and 2 achieved commercial operation on February 13, 1986 and September 22, 1986, respectively, while Unit 3 has a forecast date for commercial operation in the third quarter of 1987. The System 80 design incorporates a reactor power cutback system (RPCS) feature which reduces plant trips caused by two common initiating events: loss of load/turbine trip (LOL) and loss of one main feedwater pump (LOMFWP). The key design objective of the RPCS is to improve overall plant availability and performance, while minimizing challenges to the plant safety system

  20. Approach to criticality in cold core of the Unit 1 of the cycle 10 of the Laguna Verde power plant with control rods similar in design to the original ones and the advanced ones; Aproximacion a criticidad en frio de la Unidad 1 del ciclo 10 de la CLV con barras de control de diseno similar al original y avanzadas

    Energy Technology Data Exchange (ETDEWEB)

    Perusquia, R.; Ramirez, J.R.; Ortiz, J.J.; Hernandez, J.L.; Montes, J.L. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)]. E-mail: rpc@nuclear.inin.mx

    2004-07-01

    In the Laguna Verde power plant (CLV) worn out control bars have been replacing for control rods of advanced design. At the moment of the 109 rods of similar design to the original of the Unit 1 of the CLV, 14 of them have been substituted with two types of different advanced control rods. The same as the original rods the advanced rods use boron carbide as control element for neutrons, but additionally they use hafnium, to achieve a longer useful half life. The rods of similar design to the original are homogeneous axially on the other hand the advanced presenting several zones. In principle the advanced rods were designed to be neutronically compatible to the original rods. However the differences in the design and of constituents assumed to consider a different performance during the operation. Since the one numbers of advanced bars is growing with the number of cycles of the CLV reactor has requested to the National Institute of Nuclear Research (ININ) to evaluate in detailed form the performance of the control rods. Previously the calculations and analysis of cycle design that that were carried out assumed that control rods should be of similar design as the original. Using the HELIOS/CM-LENDS system, the effect of the inclusion of advanced rods was analyzed in the approximation of the criticality in cold (20 C) in the cycle 10 of the Unit 1. Four scenarios were poposed, where the type of the rod of substitution control is varied. The value of reactivity was calculated for the rods similar in design to the original and for the advanced one. By comparison of these values, it was found that the value of reactivity of the control rods of the advanced design was superior to the value for rods similar to the original ones by 7.6% for one of the advanced designs and of 13.6% for the other one. (Author)

  1. Neutron dosimetry. Environmental monitoring in a BWR type reactor

    International Nuclear Information System (INIS)

    Tavera D, L.; Camacho L, M.E.

    1991-01-01

    The measurements carried out on reactor dosimetry are applied mainly to the study on the effects of the radiation in 108 materials of the reactor; little is on the environmental dosimetry outside of the primary container of BWR reactors. In this work the application of a neutron spectrometer formed by plastic detectors of nuclear traces manufactured in the ININ, for the environmental monitoring in penetrations around the primary container of the unit I of the Laguna Verde central is presented. The neutron monitoring carries out with purposes of radiological protection, during the operational tests of the reactor. (Author)

  2. Neutron dosimetry. Environmental monitoring in a BWR type reactor; Dosimetria de neutrones. Monitoreo ambiental en un reactor del tipo BWR

    Energy Technology Data Exchange (ETDEWEB)

    Tavera D, L; Camacho L, M E

    1991-01-15

    The measurements carried out on reactor dosimetry are applied mainly to the study on the effects of the radiation in 108 materials of the reactor; little is on the environmental dosimetry outside of the primary container of BWR reactors. In this work the application of a neutron spectrometer formed by plastic detectors of nuclear traces manufactured in the ININ, for the environmental monitoring in penetrations around the primary container of the unit I of the Laguna Verde central is presented. The neutron monitoring carries out with purposes of radiological protection, during the operational tests of the reactor. (Author)

  3. Stability analysis of a recycling circuit of a BWR type reactor. Theoretical study

    International Nuclear Information System (INIS)

    Salinas H, J.G.; Espinosa P, G.; Gonzalez M, V.M.

    2000-01-01

    The Technology, Regulation and Services Management of the National Commission of Nuclear Safety and Safeguards financed and in coordinate form with the I.P.H. Department of the Metropolitan Autonomous-Iztapalapa University developed the present project with the purpose of studying the effect of the recycling system on the linear stability of a BWR reactor whose reference central is the Laguna Verde power station. The present project forms part of a work series focused to the linear stability of the nuclear reactor of the Unit 1 at Laguna Verde power station. The components of the recycling system considered for the study of stability are the recycling external circuit (recycling pumps, valves) and the internal circuit (downcomer, jet pumps, lower full, driers, separators). The mathematical model is obtained applying mass balances and movement quantity in each one of the mentioned circuits. With respect to the nucleus model two regions are considered, the first one is made of a flow in one phase and the second one of a flow in two phases. For modelling the biphasic region it is considered homogenous flow. Generally it is studied the system behavior in the frequency domain starting from the transfer function applied to four operational states which correspond to the lower stability zone in the map power-flow of the Unit 1 of Laguna Verde power station. The Nyquist diagrams corresponding to each state as well as their characteristic frequency were determined. The results show that exists a very clear dependence of the power-flow relation on the stability of the system. It was found that the boiling length is an important parameter for the linear stability of the system. The obtained results show that the characteristic frequencies in unstability zones are similar to the reported data of the Unit 1 of the Laguna Verde power station in the event of power oscillations carried out in January 1995. (Author)

  4. MCTP, a code for the thermo-mechanical analysis of a fuel rod of BWR type reactors (Neutron part); MCTP, un codigo para el analisis termo-mecanico de una barra combustible de reactores tipo BWR (Parte Neutronica)

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez L, H; Ortiz V, J [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    In the National Institute of Nuclear Research of Mexico a code for the thermo-mechanical analysis of the fuel rods of the BWR type reactors of the Nucleo electric Central of Laguna Verde is developed. The code solves the diffusion equation in cylindrical coordinates with several energy groups. The code, likewise, calculates the temperature distribution and power distribution in those fuel rods. The code is denominated Multi groups With Temperatures and Power (MCTP). In the code, the energy with which the fission neutrons are emitted it is divided in six groups. They are also considered the produced perturbations by the changes in the temperatures of the materials that constitute the fuel rods, the content of fission products, the uranium consumption and in its case the gadolinium, as well as the plutonium production. In this work there are present preliminary results obtained with the code, using data of operation of the Nucleo electric Central of Laguna Verde. (Author)

  5. MCTP, a code for the thermo-mechanical analysis of a fuel rod of BWR type reactors (Neutron part)

    International Nuclear Information System (INIS)

    Hernandez L, H.; Ortiz V, J.

    2003-01-01

    In the National Institute of Nuclear Research of Mexico a code for the thermo-mechanical analysis of the fuel rods of the BWR type reactors of the Nucleo electric Central of Laguna Verde is developed. The code solves the diffusion equation in cylindrical coordinates with several energy groups. The code, likewise, calculates the temperature distribution and power distribution in those fuel rods. The code is denominated Multi groups With Temperatures and Power (MCTP). In the code, the energy with which the fission neutrons are emitted it is divided in six groups. They are also considered the produced perturbations by the changes in the temperatures of the materials that constitute the fuel rods, the content of fission products, the uranium consumption and in its case the gadolinium, as well as the plutonium production. In this work there are present preliminary results obtained with the code, using data of operation of the Nucleo electric Central of Laguna Verde. (Author)

  6. Stability analysis of a recycling circuit of a BWR type reactor. Theoretical study; Analisis de estabilidad de un circuito de recirculacion de un reactor del tipo BWR. Estudio teorico

    Energy Technology Data Exchange (ETDEWEB)

    Salinas H, J.G.; Espinosa P, G. [Universidad Autonoma Metropolitana-Iztapalapa, 09000 Mexico D.F. (Mexico); Gonzalez M, V.M. [Comision Nacional de Seguridad Nuclear y Salvaguardias, 04000 Mexico D.F. (Mexico)

    2000-07-01

    The Technology, Regulation and Services Management of the National Commission of Nuclear Safety and Safeguards financed and in coordinate form with the I.P.H. Department of the Metropolitan Autonomous-Iztapalapa University developed the present project with the purpose of studying the effect of the recycling system on the linear stability of a BWR reactor whose reference central is the Laguna Verde power station. The present project forms part of a work series focused to the linear stability of the nuclear reactor of the Unit 1 at Laguna Verde power station. The components of the recycling system considered for the study of stability are the recycling external circuit (recycling pumps, valves) and the internal circuit (downcomer, jet pumps, lower full, driers, separators). The mathematical model is obtained applying mass balances and movement quantity in each one of the mentioned circuits. With respect to the nucleus model two regions are considered, the first one is made of a flow in one phase and the second one of a flow in two phases. For modelling the biphasic region it is considered homogenous flow. Generally it is studied the system behavior in the frequency domain starting from the transfer function applied to four operational states which correspond to the lower stability zone in the map power-flow of the Unit 1 of Laguna Verde power station. The Nyquist diagrams corresponding to each state as well as their characteristic frequency were determined. The results show that exists a very clear dependence of the power-flow relation on the stability of the system. It was found that the boiling length is an important parameter for the linear stability of the system. The obtained results show that the characteristic frequencies in unstability zones are similar to the reported data of the Unit 1 of the Laguna Verde power station in the event of power oscillations carried out in January 1995. (Author)

  7. Desalination plan with nuclear reactors as part of a sustainable development program in Mexico

    International Nuclear Information System (INIS)

    Rojas A, O; Calleros M, G.

    2016-09-01

    This paper presents a project for the desalination of seawater with nuclear reactors, in order to supply fresh water to the populations near to the nuclear power plant. A case study is proposed with the nuclear power plant of Laguna Verde, implementing a system that allows taking advantage of the residual heat of the seawater condensate stage and with this, to supply drinking water to the surrounding localities where the vital liquid is scarce. In addition, legislation is proposed to allow some of the thermal energy generated by reactors producing electrical energy in Mexico to be used for the desalination of seawater and/or hydrogen production. (Author)

  8. Desalination plan with nuclear reactors as part of a sustainable development program in Mexico; Plan de desalinizacion con reactores nucleares como parte de un programa de desarrollo sustentable en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Rojas A, O; Calleros M, G., E-mail: oziel.rojas.siimisa@gmail.com [Soluciones en Instrumentacion Integral y Mantenimiento Industrial y Servicios, S. A. de C. V. (Mexico)

    2016-09-15

    This paper presents a project for the desalination of seawater with nuclear reactors, in order to supply fresh water to the populations near to the nuclear power plant. A case study is proposed with the nuclear power plant of Laguna Verde, implementing a system that allows taking advantage of the residual heat of the seawater condensate stage and with this, to supply drinking water to the surrounding localities where the vital liquid is scarce. In addition, legislation is proposed to allow some of the thermal energy generated by reactors producing electrical energy in Mexico to be used for the desalination of seawater and/or hydrogen production. (Author)

  9. Cape Verde

    Science.gov (United States)

    2007-01-01

    This Mars Exploration Rover Opportunity Pancam 'super resolution' mosaic of the approximately 6 m (20 foot) high cliff face of the Cape Verde promontory was taken by the rover from inside Victoria Crater, during the rover's descent into Duck Bay. Super-resolution is an imaging technique which utilizes information from multiple pictures of the same target in order to generate an image with a higher resolution than any of the individual images. Cape Verde is a geologically rich outcrop and is teaching scientists about how rocks at Victoria crater were modified since they were deposited long ago. This image complements super resolution mosaics obtained at Cape St. Mary and Cape St. Vincent and is consistent with the hypothesis that Victoria crater is located in the middle of what used to be an ancient sand dune field. Many rover team scientists are hoping to be able to eventually drive the rover closer to these layered rocks in the hopes of measuring their chemistry and mineralogy. This is a Mars Exploration Rover Opportunity Panoramic Camera image mosaic acquired on sols 1342 and 1356 (November 2 and 17, 2007), and was constructed from a mathematical combination of 64 different blue filter (480 nm) images.

  10. Analysis of the integrity of the pressure vessel of the BWR type nuclear reactor

    International Nuclear Information System (INIS)

    Silva Luna, O.

    1982-01-01

    The presssure vessel of a BWR type reactor was monitored for cracking during alternating events of its in-service life. The monitoring was to determine criticality of fractures catastrophic fractures and the velocity of fracture propagation. Detected cracks were evaluated as specified in ASME code section XI, of a minimum wall thickness of 2.5% crack growths were compared a) of 1/10 of the critical maximum size and b) at in-service inspection intervals according to ASME recommendations to be established at the Laguna Verde nuclear plant. Finally conclusions are made and discussed. (author)

  11. Modernization and power increase nuclear power plant Laguna Verde (Mexico)

    International Nuclear Information System (INIS)

    Garcia-Serrano, J. L.; Merino, A.; Ruiz Gutierrez, L.

    2011-01-01

    The objective of this project is to perform the modifications on the thermal cycle of the plant required by an Extended Power Uprate, to achieve a safe and reliable operation of the plant at 120% of its original thermal power. The scope includes the design, engineering training, supply of equipment, dismantling, installation, testing and commissioning. The duration of the project is 4 years (82007-2010), and all the modifications have been implemented in four outages, two per unit. The main modification carried out are the change of the condenser, moisture separator and main steam reheaters, the feedwater haters, the turbogenerator and its auxiliaries, transformers, isolated phase bus and main circuit breaker, etc. (Author)

  12. Simulation of the aspersion system of the core low pressure (LPCS) for a boiling water reactor (BWR) based on RELAP

    International Nuclear Information System (INIS)

    Membrillo G, O. E.; Chavez M, C.

    2012-10-01

    The present work presents the modeling and simulation of the aspersion system to low pressure of reactor of the nuclear power plant of Laguna Verde using the nuclear code RELAP/SCDAP. The objective of the emergency systems inside a nuclear reactor is the cooling of the core, nor caring the performance of any other emergency system in the case of an accident design base for coolant loss. To obtain a simulation of the system is necessary to have a model based on their main components, pipes, pumps, valves, etc. This article describes the model for the simulation of the main line and the test line for the HPCS. At the moment we have the simulation of the reactor vessel and their systems associated to the nuclear power plant of Laguna Verde, this work will allow to associate the emergency system model LPCS to the vessel model. The simulation of the vessel and the emergency systems will allow knowing the behavior of the reactor in the stage of the coolant loos, giving the possibility to analyze diverse scenarios. The general model will provide an auxiliary tool for the training in classroom and at distance in the operation of nuclear power plants. (Author)

  13. Design of an equilibrium nucleus of a BWR type reactor based in a Thorium-Uranium fuel; Diseno de un nucleo de equilibrio de un reactor tipo BWR basado en un combustible de Torio-Uranio

    Energy Technology Data Exchange (ETDEWEB)

    Francois, J.L.; Nunez C, A. [Laboratorio de Analisis en Ingenieria de Reactores Nucleares, Facultad de Ingenieria-UNAM, Paseo Cuauhnahuac 8532, Jiutepec, Morelos (Mexico)

    2003-07-01

    In this work the design of the reactor nucleus of boiling water using fuel of thorium-uranium is presented. Starting from an integral concept based in a type cover-seed assemble is carried out the design of an equilibrium reload for the nucleus of a reactor like that of the Laguna Verde Central and its are analyzed some of the main design variables like the cycle length, the reload fraction, the burnt fuel, the vacuum distribution, the generation of lineal heat, the margin of shutdown, as well as a first estimation of the fuel cost. The results show that it is feasible to obtain an equilibrium reload, comparable to those that are carried out in the Laguna Verde reactors, with a good behavior of those analyzed variables. The cost of the equilibrium reload designed with the thorium-uranium fuel is approximately 2% high that the uranium reload producing the same energy. It is concluded that it is convenient to include burnable poisons, type gadolinium, in the fuel with the end of improving the reload design, the fuel costs and the margin of shutdown. (Author)

  14. Design of an equilibrium nucleus of a BWR type reactor based in a Thorium-Uranium fuel

    International Nuclear Information System (INIS)

    Francois, J.L.; Nunez C, A.

    2003-01-01

    In this work the design of the reactor nucleus of boiling water using fuel of thorium-uranium is presented. Starting from an integral concept based in a type cover-seed assemble is carried out the design of an equilibrium reload for the nucleus of a reactor like that of the Laguna Verde Central and its are analyzed some of the main design variables like the cycle length, the reload fraction, the burnt fuel, the vacuum distribution, the generation of lineal heat, the margin of shutdown, as well as a first estimation of the fuel cost. The results show that it is feasible to obtain an equilibrium reload, comparable to those that are carried out in the Laguna Verde reactors, with a good behavior of those analyzed variables. The cost of the equilibrium reload designed with the thorium-uranium fuel is approximately 2% high that the uranium reload producing the same energy. It is concluded that it is convenient to include burnable poisons, type gadolinium, in the fuel with the end of improving the reload design, the fuel costs and the margin of shutdown. (Author)

  15. Simulation of the aspersion system of the core low pressure (LPCS) for a boiling water reactor (BWR) based on RELAP; Simulacion del sistema de aspersion del nucleo a baja presion (LPCS) para un reactor de agua en ebullicion (BWR) basado en RELAP

    Energy Technology Data Exchange (ETDEWEB)

    Membrillo G, O. E.; Chavez M, C., E-mail: garzo1012@gmail.com [UNAM, Facultad de Ingenieria, Circuito Interior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2012-10-15

    The present work presents the modeling and simulation of the aspersion system to low pressure of reactor of the nuclear power plant of Laguna Verde using the nuclear code RELAP/SCDAP. The objective of the emergency systems inside a nuclear reactor is the cooling of the core, nor caring the performance of any other emergency system in the case of an accident design base for coolant loss. To obtain a simulation of the system is necessary to have a model based on their main components, pipes, pumps, valves, etc. This article describes the model for the simulation of the main line and the test line for the HPCS. At the moment we have the simulation of the reactor vessel and their systems associated to the nuclear power plant of Laguna Verde, this work will allow to associate the emergency system model LPCS to the vessel model. The simulation of the vessel and the emergency systems will allow knowing the behavior of the reactor in the stage of the coolant loos, giving the possibility to analyze diverse scenarios. The general model will provide an auxiliary tool for the training in classroom and at distance in the operation of nuclear power plants. (Author)

  16. Solution to the incompatibility between reactor protection logic and turbine shot logic. Scram by high pressure; Solucion a la incompatibilidad entre logica de proteccion de reactor y logica de disparo de turbina. SCRAM por alta presion

    Energy Technology Data Exchange (ETDEWEB)

    Ramos Q, R.; Santiago F, C.; Gonzalez P, G., E-mail: ruben.ramos01@cfe.gob.mx [Comision Federal de Electricidad, Central Nuclear Laguna Verde, Subgerencia de Ingenieria, Carretera Cardel-Nautla Km. 42.5, Alto Lucero, Veracruz (Mexico)

    2013-10-15

    The nuclear power plant of Laguna Verde carried out the Modernization and Increase of Extended Power Project in its two Units (2005-2011). This modernization included to the electro-hydraulic control system of the main turbine, replacing an ana logical system by one digital (Digital Electro-hydraulic Control - DEHC) whose functions are of controlling the reactor pressure in the different operation ways as wells as of controlling the velocity and load of the main turbine. Also, it has protections that are related with diverse plant systems, as the Reactor Protection Systems (RPS). During the tests stage was realized a programmed load rejection, which Reactor Scram should cause when being presented the shot of main turbine. However, the logic of the RPS was inhibited due to the quick response of the new control DEHC, propitiating a condition of non prospective plant and, in consequence, the Reactor Scram happened for another protection of the RPS. (author)

  17. Using largest Lyapunov exponent to confirm the intrinsic stability of boiling water reactors

    International Nuclear Information System (INIS)

    Gavilian-Moreno, Carlos; Espinosa-Paredes, Gilberto

    2016-01-01

    The aim of this paper is the study of instability state of boiling water reactors with a method based in largest Lyapunov exponents (LLEs). Detecting the presence of chaos in a dynamical system is an important problem that is solved by measuring the LLE. Lyapunov exponents quantify the exponential divergence of initially close state-space trajectories and estimate the amount of chaos in a system. This method was applied to a set of signals from several nuclear power plant (NPP) reactors under commercial operating conditions that experienced instabilities events, apparently each of a different nature. Laguna Verde and Forsmark NPPs with in-phase instabilities, and Cofrentes NPP with out-of-phases instability. This study presents the results of intrinsic instability in the boiling water reactors of three NPPs. In the analyzed cases the limit cycle was not reached, which implies that the point of equilibrium exerts influence and attraction on system evolution

  18. Using largest Lyapunov exponent to confirm the intrinsic stability of boiling water reactors

    Energy Technology Data Exchange (ETDEWEB)

    Gavilian-Moreno, Carlos [Iberdrola Generacion, S.A., Cofrentes Nuclear Power Plant, Project Engineering Department, Paraje le Plano S/N, Valencia (Spain); Espinosa-Paredes, Gilberto [Area de ingeniera en Recursos Energeticos, Universidad Autonoma Metropolitana-Iztapalapa, Mexico city (Mexico)

    2016-04-15

    The aim of this paper is the study of instability state of boiling water reactors with a method based in largest Lyapunov exponents (LLEs). Detecting the presence of chaos in a dynamical system is an important problem that is solved by measuring the LLE. Lyapunov exponents quantify the exponential divergence of initially close state-space trajectories and estimate the amount of chaos in a system. This method was applied to a set of signals from several nuclear power plant (NPP) reactors under commercial operating conditions that experienced instabilities events, apparently each of a different nature. Laguna Verde and Forsmark NPPs with in-phase instabilities, and Cofrentes NPP with out-of-phases instability. This study presents the results of intrinsic instability in the boiling water reactors of three NPPs. In the analyzed cases the limit cycle was not reached, which implies that the point of equilibrium exerts influence and attraction on system evolution.

  19. Using Largest Lyapunov Exponent to Confirm the Intrinsic Stability of Boiling Water Reactors

    Directory of Open Access Journals (Sweden)

    Carlos J. Gavilán-Moreno

    2016-04-01

    Full Text Available The aim of this paper is the study of instability state of boiling water reactors with a method based in largest Lyapunov exponents (LLEs. Detecting the presence of chaos in a dynamical system is an important problem that is solved by measuring the LLE. Lyapunov exponents quantify the exponential divergence of initially close state-space trajectories and estimate the amount of chaos in a system. This method was applied to a set of signals from several nuclear power plant (NPP reactors under commercial operating conditions that experienced instabilities events, apparently each of a different nature. Laguna Verde and Forsmark NPPs with in-phase instabilities, and Cofrentes NPP with out-of-phases instability. This study presents the results of intrinsic instability in the boiling water reactors of three NPPs. In the analyzed cases the limit cycle was not reached, which implies that the point of equilibrium exerts influence and attraction on system evolution.

  20. An Order Coding Genetic Algorithm to Optimize Fuel Reloads in a Nuclear Boiling Water Reactor

    International Nuclear Information System (INIS)

    Ortiz, Juan Jose; Requena, Ignacio

    2004-01-01

    A genetic algorithm is used to optimize the nuclear fuel reload for a boiling water reactor, and an order coding is proposed for the chromosomes and appropriate crossover and mutation operators. The fitness function was designed so that the genetic algorithm creates fuel reloads that, on one hand, satisfy the constrictions for the radial power peaking factor, the minimum critical power ratio, and the maximum linear heat generation rate while optimizing the effective multiplication factor at the beginning and end of the cycle. To find the values of these variables, a neural network trained with the behavior of a reactor simulator was used to predict them. The computation time is therefore greatly decreased in the search process. We validated this method with data from five cycles of the Laguna Verde Nuclear Power Plant in Mexico

  1. Cabo Verde - Private Sector Development

    Data.gov (United States)

    Millennium Challenge Corporation — The objective of the Private Sector Development Project activities of the 2005-2010 Cabo Verde Compact was to support Cabo Verde's long-term economic transformation...

  2. Palo Verde Generating Station, Units 4 and 5. License application, general information

    International Nuclear Information System (INIS)

    1978-01-01

    A license application for two more Palo Verde reactors, Units 4 and 5, is presented. The two PWR reactors have a nominal net generating power each of 1,270 MW(e). Containments are steel-lined prestressed cylindrical structures with hemispherical domes. The reactors are replicas of Palo Verde 1, 2 and 3 (see DOCKETS 50528, 50529 and 50530) using the standard Combustion Engineering System 80 (see DOCKET-STN-50470)

  3. Simulation of the injection system of cooling water to low pressure (Lpci) for a boiling water reactor (BWR) based on RELAP

    International Nuclear Information System (INIS)

    Delgado C, R. A.; Lopez S, E.; Chavez M, C.

    2012-10-01

    The present article describes the modeling and simulation of the Injection System of Cooling Water to Low Pressure (Lpci) for the nuclear power plant of Laguna Verde. Is very important to be able to predict the behavior of the nuclear plant in the case of an emergency stop, and while nearer to the reality are the results of a simulation, better is the safety protocol that can be devised. In the Engineering Faculty of the UNAM at the present is had logical models of the safety systems, but due to the nature of the same, these simulations do not provide of the quantity of enough information to be able to reproduce with more accuracy the behavior of the Lpci in the case of a severe accident. For this reason, the RELAP code was used for the flows modeling, components and structures of heat transfers in relation to the system Lpci. The modeling of the components is carried out with base on technical information of the nuclear plant and the results will be corroborated with information in reference documents as the Rasp (the Reactor analysis support package) and the Fsar (Final safety analysis report) for the nuclear power plant of Laguna Verde. (Author)

  4. Simulation of the injection system of cooling water to low pressure (Lpci) for a boiling water reactor (BWR) based on RELAP; Simulacion del sistema de inyeccion de agua de refrigeracion a baja presion (LPCI) para un reactor de agua en ebullicion (BWR) basado en RELAP

    Energy Technology Data Exchange (ETDEWEB)

    Delgado C, R. A.; Lopez S, E.; Chavez M, C., E-mail: renedelgado2015@hotmail.com [UNAM, Facultad de Ingenieria, Circuito Interior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2012-10-15

    The present article describes the modeling and simulation of the Injection System of Cooling Water to Low Pressure (Lpci) for the nuclear power plant of Laguna Verde. Is very important to be able to predict the behavior of the nuclear plant in the case of an emergency stop, and while nearer to the reality are the results of a simulation, better is the safety protocol that can be devised. In the Engineering Faculty of the UNAM at the present is had logical models of the safety systems, but due to the nature of the same, these simulations do not provide of the quantity of enough information to be able to reproduce with more accuracy the behavior of the Lpci in the case of a severe accident. For this reason, the RELAP code was used for the flows modeling, components and structures of heat transfers in relation to the system Lpci. The modeling of the components is carried out with base on technical information of the nuclear plant and the results will be corroborated with information in reference documents as the Rasp (the Reactor analysis support package) and the Fsar (Final safety analysis report) for the nuclear power plant of Laguna Verde. (Author)

  5. Analysis of the rotation accident of assemblies in boiling water reactors

    International Nuclear Information System (INIS)

    Becerril-Gonzalez M, J. J.; Fuentes M, L.; Castillo M, J. A.; Ortiz S, J. J.; Perusquia de Cueto, R.

    2012-10-01

    For this work was analyzed the impact that would cause the load of a rotated fuel assembly in the behaviour of the core in the Cycle 14 of the Unit 1 of the nuclear power plant of Laguna Verde. To carry out this analysis the code Simulate-3 was used, with which was possible to analyze the behavior of the effective multiplication factor and the thermal limits (MAPRAT, MFLPD and MFLCPR). The rotation of fuel assemblies to 90, 180 and 270 grades was analyzed with regard to the design position, with 0, 1, 2 and 3 burnt cycles for these assemblies. The results show that the thermal limits remain inside the allowed values, therefore if this accident type happened the reactor could continue operating in a sure way. (Author)

  6. 2013 Tres Lagunas Post Fire, 14

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  7. 2013 Tres Lagunas Post Fire, 26

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  8. 2013 Tres Lagunas Post Fire, 3

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  9. 2013 Tres Lagunas Post Fire, 33

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  10. 2013 Tres Lagunas Post Fire, 8

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  11. 2013 Tres Lagunas Post Fire, 18

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  12. 2013 Tres Lagunas Post Fire, 11

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  13. 2013 Tres Lagunas Post Fire, 17

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  14. 2013 Tres Lagunas Post Fire, 30

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  15. 2013 Tres Lagunas Post Fire, 5

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  16. 2013 Tres Lagunas Post Fire, 4

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  17. 2013 Tres Lagunas Post Fire, 12

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  18. 2013 Tres Lagunas Post Fire, 7

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  19. 2013 Tres Lagunas Post Fire, 32

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  20. 2013 Tres Lagunas Post Fire, 1

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  1. 2013 Tres Lagunas Post Fire, 28

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  2. 2013 Tres Lagunas Post Fire, 9

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  3. 2013 Tres Lagunas Post Fire, 35

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  4. 2013 Tres Lagunas Post Fire, 31

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  5. 2013 Tres Lagunas Post Fire, 21

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  6. 2013 Tres Lagunas Post Fire, 27

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  7. 2013 Tres Lagunas Post Fire, 6

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  8. 2013 Tres Lagunas Post Fire, 24

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  9. 2013 Tres Lagunas Post Fire, 34

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — USDA USFS Southwestern Region Contract # AG-8371-C-10-0011 Delivery # AG-8371-D-13-0056 DIGITAL PHOTOGRAPHY ACQUISITION, TRES LAGUNAS FIRE, NEW MEXICO Project...

  10. Análisis prospectivo del conflicto político ambiental, sobre el uso del espacio público Parque La Laguna, localizado en la Urbanización Nueva Casarapa, Estado Miranda.Venezuela

    Directory of Open Access Journals (Sweden)

    Mildred Zerpa

    2013-06-01

    Full Text Available Nueva Casarapa, es un complejo urbanístico integral concebido bajo el concepto de ciudad. Posee espacios abiertos, centros comerciales, espacios verdes y públicos cuidados por los propios habitantes y un parque central conocido como La Laguna. En 2009 comenzó una polémica que podría convertirse en conflicto socio natural con implicaciones en la gestión integral de riesgo del Municipio Plaza, por la incertidumbre acerca de cuál grupo es el más indicado para administrar y gestionar el parque La Laguna.

  11. Simulation of the fault transitory of the feedwater controller in a Boiling water reactor with the Ramona-3B code

    International Nuclear Information System (INIS)

    Hernandez M, J.L.; Ortiz V, J.

    2005-01-01

    The obtained results when carrying out the simulation of the fault transitory of the feedwater controller (FCAA) with the Ramona-3B code, happened in the Unit 2 of the Laguna Verde power plant (CNLV), in September of the year 2000 are presented. The transitory originates as consequence of the controller's fault of speed of a turbo pump of feedwater. The work includes a short description of the event, the suppositions considered for the simulation and the obtained results. Also, a discussion of the impact of the transitory event is presented on aspects of reactor safety. Although the carried out simulation is limited by the capacities of the code and for the lack of available information, it was found that even in a conservative situation, the power was incremented only in 12% above the nominal value, while that the thermal limit determined by the minimum reason of the critical power, MCPR, always stayed above the limit values of operation and safety. (Author)

  12. Modernization and power uprate of the Laguna Verde Nuclear Power Plant (Mexico); Modernizacion y aumento de potencia de la Central Nuclear Laguna Verde (Mexico)

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, L.; Merino, A.; Garcia-Serrano, J. L.

    2012-11-01

    The objective of this project is to perform the modifications on the thermal cycle of the plant required by an Extended Power Update, to achieve a safe and reliable operation of the plant at 120% of its original thermal power. The scope includes the design, engineering, training, supply of equipment, dismantling, installation, testing and commissioning. The duration of the project is 4,5 years (2007-2011), and all the modifications have been implemented in four outages, two per unit. The main modification carried out are the change of the condenser, moisture separator and main steam reheaters, the feedwater haters, the turbogenerator and its auxiliaries, transformers, isolated phase bus and main circuit breaker, etc. In this paper, the results obtained after all the modifications will be introduced. In addition, the most representative experience will be presented, as well as the lessons learned during the Project execution. (Author)

  13. Modernization and power increase nuclear power plant Laguna Verde (Mexico); Modernizacion y aumento de potencia de la central nuclear Laguna Verde (Mexico)

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Serrano, J. L.; Merino, A.; Ruiz Gutierrez, L.

    2011-07-01

    The objective of this project is to perform the modifications on the thermal cycle of the plant required by an Extended Power Uprate, to achieve a safe and reliable operation of the plant at 120% of its original thermal power. The scope includes the design, engineering training, supply of equipment, dismantling, installation, testing and commissioning. The duration of the project is 4 years (82007-2010), and all the modifications have been implemented in four outages, two per unit. The main modification carried out are the change of the condenser, moisture separator and main steam reheaters, the feedwater haters, the turbogenerator and its auxiliaries, transformers, isolated phase bus and main circuit breaker, etc. (Author)

  14. Simulation of the automatic depressurization system (Ads) for a boiling water reactor (BWR) based on RELAP

    International Nuclear Information System (INIS)

    Ramirez G, C.; Chavez M, C.

    2012-10-01

    The automatic depressurization system (Ads) of the boiling water reactor (BWR) like part of the emergency cooling systems is designed to liberate the vapor pressure of the reactor vessel, as well as the main vapor lines. At the present time in the Engineering Faculty, UNAM personnel works in the simulation of the Laguna Verde reactor based on the nuclear code RELAP/SCADAP and in the incorporation to the same of the emergency cooling systems. The simulation of the emergency cooling systems began with the inclusion of two hydrodynamic volumes, one source and another drain, and the incorporation of the initiation logic for each emergency system. In this work is defined and designed a simplified model of Ads of the reactor, considering a detail level based on the main elements that compose it. As tool to implement the proposed model, the RELAP code was used. The simulated main functions of Ads are centered in the quick depressurization of the reactor by means of the vapor discharge through the relief/safety valves to the suppression pool, and, in the event of break of the main vapor line, the reduction of the vessel pressure operates for that the cooling systems of the core to low pressure (Lpcs and Lpci) they can begin their operation. (Author)

  15. Simulation of the automatic depressurization system (Ads) for a boiling water reactor (BWR) based on RELAP; Simulacion del sistema de despresurizacion automatica (ADS) para un reactor de agua en ebullicion (BWR) basado en RELAP

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez G, C.; Chavez M, C., E-mail: ces.raga@gmail.com [UNAM, Facultad de Ingenieria, Circuito Interior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2012-10-15

    The automatic depressurization system (Ads) of the boiling water reactor (BWR) like part of the emergency cooling systems is designed to liberate the vapor pressure of the reactor vessel, as well as the main vapor lines. At the present time in the Engineering Faculty, UNAM personnel works in the simulation of the Laguna Verde reactor based on the nuclear code RELAP/SCADAP and in the incorporation to the same of the emergency cooling systems. The simulation of the emergency cooling systems began with the inclusion of two hydrodynamic volumes, one source and another drain, and the incorporation of the initiation logic for each emergency system. In this work is defined and designed a simplified model of Ads of the reactor, considering a detail level based on the main elements that compose it. As tool to implement the proposed model, the RELAP code was used. The simulated main functions of Ads are centered in the quick depressurization of the reactor by means of the vapor discharge through the relief/safety valves to the suppression pool, and, in the event of break of the main vapor line, the reduction of the vessel pressure operates for that the cooling systems of the core to low pressure (Lpcs and Lpci) they can begin their operation. (Author)

  16. Development of a simplified methodology for the isotopic determination of fuel spent in Light Water Reactors

    International Nuclear Information System (INIS)

    Hernandez N, H.; Francois L, J.L.

    2005-01-01

    The present work presents a simplified methodology to quantify the isotopic content of the spent fuel of light water reactors; their application is it specific to the Laguna Verde Nucleo electric Central by means of a balance cycle of 18 months. The methodology is divided in two parts: the first one consists on the development of a model of a simplified cell, for the isotopic quantification of the irradiated fuel. With this model the burnt one is simulated 48,000 MWD/TU of the fuel in the core of the reactor, taking like base one fuel assemble type 10x10 and using a two-dimensional simulator for a fuel cell of a light water reactor (CPM-3). The second part of the methodology is based on the creation from an isotopic decay model through an algorithm in C++ (decay) to evaluate the amount, by decay of the radionuclides, after having been irradiated the fuel until the time in which the reprocessing is made. Finally the method used for the quantification of the kilograms of uranium and obtained plutonium of a normalized quantity (1000 kg) of fuel irradiated in a reactor is presented. These results will allow later on to make analysis of the final disposition of the irradiated fuel. (Author)

  17. Capturing the design bases on Palo Verde

    International Nuclear Information System (INIS)

    Rogers, A.C.; Prawlocki, F.C.

    1989-01-01

    Over the past several years, the nuclear power industry has been directing considerable attention to plant configuration control. Utilities have been put in difficult situations due to changes made in plants without full original design basis knowledge. Once a plant is constructed, there is often insufficient information from the reactor designer or the architect/engineer to properly support operations, especially changes to the plant. In many cases utilities do not know the design bases for their units. As a result of these concerns, many utilities have been searching for ways to define the appropriate design bases for their plant. This paper discusses steps taken by Palo Verde to produce a design bases document and how it is being used to support the operation of the three nuclear units

  18. Leak rates and structural integrity tests for Laguna Verde Nuclear Power Plant primary containment. Regulatory experience

    International Nuclear Information System (INIS)

    Mamani Alegria, Yuri Raul; Salgado Gonzalez, Julio Ricardo

    1996-01-01

    In the Appendix A General Design Criteria for Nuclear Power Plants of the US Code of Federal Regulations title 10 part 50 (10CFR50) is established the Criterion 1 Quality standards and records which requires that structures, systems and components important to safety should be tested to quality standards according with the importance of the safety function to be performed. This regulation has been adopted by the Mexican Regulatory Body (CNSNS) for their nuclear power plants. (author)

  19. Modernization and power uprate of the Laguna Verde Nuclear Power Plant (Mexico)

    International Nuclear Information System (INIS)

    Ruiz, L.; Merino, A.; Garcia-Serrano, J. L.

    2012-01-01

    The objective of this project is to perform the modifications on the thermal cycle of the plant required by an Extended Power Uprate, to achieve a safe and reliable operation of the plant at 120% of its original thermal power. The scope includes the design, engineering, training, supply of equipment, dismantling, installation, testing and commissioning. The duration of the project is 4,5 years (2007-2011), and all the modifications have been implemented in four outages, two per unit. The main modification carried out are the change of the condenser, moisture separator and main steam reheaters, the feedwater haters, the turbogenerator and its auxiliaries, transformers, isolated phase bus and main circuit breaker, etc. In this paper, the results obtained after all the modifications will be introduced. In addition, the most representative experience will be presented, as well as the lessons learned during the Project execution. (Author)

  20. Tourism in Laguna (SC): Impacts and attitude.

    OpenAIRE

    Susana de Araujo Gastal; Sandra Dall'Agnol

    2012-01-01

    The places by the sea, as spaces of tourism and second homes, suffer the impacts from the activity. The local population attitude, seeing these places as bonuses or otherwise, as a burden, contributes to the viability of tourism in the locality. This article aims to present a research, methodologically related to attitude construct of social psychology, conducted in Laguna, Santa Catarina, Brazil to evaluate the relationship between the community and the different impacts caused by tourism,. ...

  1. Palo Verde College Facts, 2001.

    Science.gov (United States)

    Palo Verde Coll., Blythe, CA.

    This is a 2001 report on Palo Verde College (PVC) (California) student demographics, enrollment status, citizenship, educational goals, and academic persistence. Student data were collected and analyzed to meet accrediting standards, improve institutional effectiveness, and fulfill the local district's mission. The report discusses enrollment…

  2. Development of a simplified methodology for the isotopic determination of fuel spent in Light Water Reactors; Desarrollo de una metodologia simplificada para la determinacion isotopica del combustible gastado en reactores de agua ligera

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez N, H.; Francois L, J.L. [FI-UNAM, 04510 Mexico D.F. (Mexico)]. e-mail: hermilo@lairn.fi-b.unam.mx

    2005-07-01

    The present work presents a simplified methodology to quantify the isotopic content of the spent fuel of light water reactors; their application is it specific to the Laguna Verde Nucleo electric Central by means of a balance cycle of 18 months. The methodology is divided in two parts: the first one consists on the development of a model of a simplified cell, for the isotopic quantification of the irradiated fuel. With this model the burnt one is simulated 48,000 MWD/TU of the fuel in the core of the reactor, taking like base one fuel assemble type 10x10 and using a two-dimensional simulator for a fuel cell of a light water reactor (CPM-3). The second part of the methodology is based on the creation from an isotopic decay model through an algorithm in C++ (decay) to evaluate the amount, by decay of the radionuclides, after having been irradiated the fuel until the time in which the reprocessing is made. Finally the method used for the quantification of the kilograms of uranium and obtained plutonium of a normalized quantity (1000 kg) of fuel irradiated in a reactor is presented. These results will allow later on to make analysis of the final disposition of the irradiated fuel. (Author)

  3. Selection of nuclear reactors through the hierarchic analysis process: the Mexican case

    International Nuclear Information System (INIS)

    Martin del Campo, C.; Nelson, P.F.; Francois, J.L.

    2008-01-01

    In this work the decision making method known as hierarchical analysis process for the selection of a new reactor in Mexico was applied. The main objective of the process it is to select the nuclear reactor technology more appropriate for Mexico, to begin the bid process inside one or two years to begin their operation in 2016. The options were restricted to four reactors that fulfill the following ones approaches: 1) its are advanced reactors, from the technological point of view, with regard to the reactors that at the moment operate in the Laguna Verde Power Station, 2) its are reactors that have the totally finished design, 3) its are reactors that already have the certification on the part of the regulator organism of the origin country or that they are in an advanced state of the certification process and 4) its are reactors offered by the companies that they have designed and built the greater number of reactors that are at the moment in operation at world level. Taking into account these restrictions it was decided to consider as alternative at the reactors: Advanced Boiling Water Reactor (A BWR), European Reactor of Pressurized Water (EPR), Water at Pressure reactor (AP1000) and Simplified Economic Reactor of Boiling Water (ESBWR). The evaluation approaches include economic and of safety indicators, qualitative some of them and other quantitative ones. Another grade of complexity in the solution of the problem is that there are actors that can be involved in the definition of the evaluation approaches and in the definition of the relative importance among them, according to each actor's interests. To simplify the problem its were only considered two actors or groups of interest that can influence in more significant way and that are the Federal Commission of Electricity and the National Commission of Nuclear Safety and Safeguards. The qualifications for each reactor in function of the evaluation approaches were obtained, being the A BWR the best qualified

  4. Azcaxalli: A system based on Ant Colony Optimization algorithms, applied to fuel reloads design in a Boiling Water Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Esquivel-Estrada, Jaime, E-mail: jaime.esquivel@fi.uaemex.m [Facultad de Ingenieria, Universidad Autonoma del Estado de Mexico, Cerro de Coatepec S/N, Toluca de Lerdo, Estado de Mexico 50000 (Mexico); Instituto Nacional de Investigaciones Nucleares, Carr. Mexico Toluca S/N, Ocoyoacac, Estado de Mexico 52750 (Mexico); Ortiz-Servin, Juan Jose, E-mail: juanjose.ortiz@inin.gob.m [Instituto Nacional de Investigaciones Nucleares, Carr. Mexico Toluca S/N, Ocoyoacac, Estado de Mexico 52750 (Mexico); Castillo, Jose Alejandro; Perusquia, Raul [Instituto Nacional de Investigaciones Nucleares, Carr. Mexico Toluca S/N, Ocoyoacac, Estado de Mexico 52750 (Mexico)

    2011-01-15

    This paper presents some results of the implementation of several optimization algorithms based on ant colonies, applied to the fuel reload design in a Boiling Water Reactor. The system called Azcaxalli is constructed with the following algorithms: Ant Colony System, Ant System, Best-Worst Ant System and MAX-MIN Ant System. Azcaxalli starts with a random fuel reload. Ants move into reactor core channels according to the State Transition Rule in order to select two fuel assemblies into a 1/8 part of the reactor core and change positions between them. This rule takes into account pheromone trails and acquired knowledge. Acquired knowledge is obtained from load cycle values of fuel assemblies. Azcaxalli claim is to work in order to maximize the cycle length taking into account several safety parameters. Azcaxalli's objective function involves thermal limits at the end of the cycle, cold shutdown margin at the beginning of the cycle and the neutron effective multiplication factor for a given cycle exposure. Those parameters are calculated by CM-PRESTO code. Through the Haling Principle is possible to calculate the end of the cycle. This system was applied to an equilibrium cycle of 18 months of Laguna Verde Nuclear Power Plant in Mexico. The results show that the system obtains fuel reloads with higher cycle lengths than the original fuel reload. Azcaxalli results are compared with genetic algorithms, tabu search and neural networks results.

  5. Evaluation of the radial design of fuel cells in an operation cycle of a BWR reactor

    International Nuclear Information System (INIS)

    Gonzalez C, J.; Martin del Campo M, C.

    2003-01-01

    This work is continuation of one previous in the one that the application of the optimization technique called Tabu search to the radial design of fuel cells of boiling water reactors (BWR, Boiling Water Reactor) is presented. The objective function used in the optimization process only include neutron parameters (k-infinite and peak of radial power) considering the cell at infinite media. It was obtained to reduce the cell average enrichment completing the characteristics of reactivity of an original cell. The objective of the present work is to validate the objective function that was used for the radial design of the fuel cell (test cell), analyzing the operation of a one cycle of the reactor in which fuels have been fresh recharged that contain an axial area with the nuclear database of the cell designed instead of the original cell. For it is simulated it with Cm-Presto the cycle 10 of the reactor operation of the Unit 1 of the Nuclear Power station of Laguna Verde (U1-CNLV). For the cycle evaluation its were applied so much the simulation with the Haling strategy, as the simulation of the one cycle with control rod patterns and they were evaluated the energy generation and several power limits and reactivity that are used as design parameters in fuel reloads of BWR reactors. The results at level of an operation cycle of the reactor, show that the objective function used in the optimization and radial design of the cell is adequate and that it can induce to one good use of the fuel. (Author)

  6. Future perspectives in neutrino physics: The Laguna-LBNO case

    CERN Document Server

    Buizza Avanzini, M

    2013-01-01

    LAGUNA-LBNO is a Design Study funded by the European Commission to develop the de- sign of a deep underground neutrino observatory; its physics program involves the study of neutrino oscillations at long baselines, the investigation of the Grand Unication of elemen- tary forces and the detection of neutrinos from known and unknown astrophysical sources. Building on the successful format and on the ndings of the previous LAGUNA Design Study, LAGUNA-LBNO is more focused and is specically considering Long Baseline Neutrino Oscil- lations (LBNO) with neutrino beams from CERN. Two sites, Frejus (in France at 130 km) and Pyhasalmi (in Finland at 2300 km), are being considered. Three dierent detector technolo- gies are being studied: Water Cherenkov, Liquid Scintillator and Liquid Argon. Recently the LAGUNA-LBNO consortium has submitted an Expression of Interest for a very long baseline neutrino experiment, selecting as a rst priority the option of a Liquid Argon detector at Pyhasalmi.

  7. Tourism in Laguna (SC: Impacts and attitude.

    Directory of Open Access Journals (Sweden)

    Susana de Araujo Gastal

    2012-04-01

    Full Text Available The places by the sea, as spaces of tourism and second homes, suffer the impacts from the activity. The local population attitude, seeing these places as bonuses or otherwise, as a burden, contributes to the viability of tourism in the locality. This article aims to present a research, methodologically related to attitude construct of social psychology, conducted in Laguna, Santa Catarina, Brazil to evaluate the relationship between the community and the different impacts caused by tourism,. Data collection, using an instrument originally proposed and validated by Molero and Cuadrado (2006, allowed the analysis to forward the position of residents on the effects of tourism in the place, evaluating eight impacts factors: environmental; delinquency; everyday life; perceived importance of tourism; public services and infrastructure; intercultural; employment; and values. The results indicate that most impacts are positive on younger residents, and in the environmental, crime and social values the impact is indifferent.

  8. Expectations for the Laguna foil implosion experiments

    International Nuclear Information System (INIS)

    Greene, A.; Brownell, J.; Caird, R.; Goforth, J.; Price, R.; Trainor, J.

    1987-01-01

    Building on the results achieved in the Pioneer shot series, the Los Alamos Trailmaster project is embarking on the Laguna foil implosion experiments. In this series a Mark-IX helical generator will be coupled to an explosively formed fuse opening switch, a surface-tracking closing switch, and a vacuum power flow and load chamber. In this paper the system design will be discussed and results from zero-, one-, and two-dimensional MHD simulations will be presented. It is anticipated that the generator will provide more than 10 MA of which ∼5.5 MA will be switched to the 5-cm-radius, 2-cm-high, 250-nm-thick aluminum foil load. This should give rise to a 1 μs implosion with more than 100 kJ of kinetic energy

  9. Evaluation of the radial design of fuel cells in an operation cycle of a BWR reactor; Evaluacion del diseno radial de celdas de combustible en un ciclo de operacion de un reactor BWR

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez C, J.; Martin del Campo M, C. [Laboratorio de Analisis en Ingenieria de Reactores Nucleares, Facultad de Ingenieria, UNAM, Paseo Cuauhnahuac 8532, Jiutepec, Morelos (Mexico)]. e-mail: jgco@ver.megared.net.mx

    2003-07-01

    This work is continuation of one previous in the one that the application of the optimization technique called Tabu search to the radial design of fuel cells of boiling water reactors (BWR, Boiling Water Reactor) is presented. The objective function used in the optimization process only include neutron parameters (k-infinite and peak of radial power) considering the cell at infinite media. It was obtained to reduce the cell average enrichment completing the characteristics of reactivity of an original cell. The objective of the present work is to validate the objective function that was used for the radial design of the fuel cell (test cell), analyzing the operation of a one cycle of the reactor in which fuels have been fresh recharged that contain an axial area with the nuclear database of the cell designed instead of the original cell. For it is simulated it with Cm-Presto the cycle 10 of the reactor operation of the Unit 1 of the Nuclear Power station of Laguna Verde (U1-CNLV). For the cycle evaluation its were applied so much the simulation with the Haling strategy, as the simulation of the one cycle with control rod patterns and they were evaluated the energy generation and several power limits and reactivity that are used as design parameters in fuel reloads of BWR reactors. The results at level of an operation cycle of the reactor, show that the objective function used in the optimization and radial design of the cell is adequate and that it can induce to one good use of the fuel. (Author)

  10. Reactor

    International Nuclear Information System (INIS)

    Toyama, Masahiro; Kasai, Shigeo.

    1978-01-01

    Purpose: To provide a lmfbr type reactor wherein effusion of coolants through a loop contact portion is reduced even when fuel assemblies float up, and misloading of reactor core constituting elements is prevented thereby improving the reactor safety. Constitution: The reactor core constituents are secured in the reactor by utilizing the differential pressure between the high-pressure cooling chamber and low-pressure cooling chamber. A resistance port is formed at the upper part of a connecting pipe, and which is connect the low-pressure cooling chamber and the lower surface of the reactor core constituent. This resistance part is formed such that the internal sectional area of the connecting pipe is made larger stepwise toward the upper part, and the cylinder is formed larger so that it profiles the inner surface of the connecting pipe. (Aizawa, K.)

  11. Burrowing Owl - Palo Verde Valley [ds197

    Data.gov (United States)

    California Natural Resource Agency — These burrowing owl observations were collected during the spring and early summer of 1976 in the Palo Verde Valley, eastern Riverside County, California. This is an...

  12. Reactor

    International Nuclear Information System (INIS)

    Ikeda, Masaomi; Kashimura, Kazuo; Inoue, Kazuyuki; Nishioka, Kazuya.

    1979-01-01

    Purpose: To facilitate the construction of a reactor containment building, whereby the inspections of the outer wall of a reactor container after the completion of the construction of the reactor building can be easily carried out. Constitution: In a reactor accommodated in a container encircled by a building wall, a space is provided between the container and the building wall encircling the container, and a metal wall is provided in the space so that it is fitted in the building wall in an attachable or detatchable manner. (Aizawa, K.)

  13. Palo Verde nuclear dynamic analysis (PANDA)

    International Nuclear Information System (INIS)

    Girjashankar, P.V.; Secker, P.A. Jr.; LeClair, S.J.; Mendoza, J.; Webb, J.R.

    1988-01-01

    Arizona Nuclear Power Project (ANPP) has initiated the development of a large scale dynamic analysis computer program for the Palo Verde Nuclear Generating Station (PVNGS). This paper presents the decision processes and preliminary development activities that have been pursued related to the code development. The PANDA (Palo Verde Nuclear Dynamic Analysis) code will be used for a variety of applications as described in this paper

  14. Komposisi dan Kemelimpahan Fitoplankton di Laguna Glagah Kabupaten Kulonprogo Provinsi Daerah Istimewa YOGYAKARTA

    OpenAIRE

    Ramadani, Aisyah Hadi; Wijayanti, Arini; Hadisusanto, Suwarno

    2013-01-01

    Penelitian bertujuan untuk: 1) mengidentifikasi jenis fitoplankton di laguna Glagah; 2) meng-identifikasi kemelimpahan fitoplankton di laguna Glagah; 3) mempelajari hubungan faktor fisiko-kimia lingkungan dengan kemelimpahan fitoplankton di laguna Glagah. Penelitian dilaksanakan pada tanggal 10 Desember 2012 di laguna Glagah desa Glagah kecamatan Temon Kabupaten Kulonprogo DIY. Pengambilan sampel dilakukan pada 3 stasiun pengamatan untuk mengidentifikasi faktor fisiko-kimia (pH, DO, dan al...

  15. Escuela Superior de Palos Verdes

    Directory of Open Access Journals (Sweden)

    Neutra, Richard J.

    1965-02-01

    Full Text Available Before initiating the building operations for the «Palos Verdes» School, the site was divided into two large horizontal surfaces, at different levels. The lower one served to accommodate the playing fields, a car park, the physical training building, and shop and ancillary buildings. On the higher of these two surfaces, and to the West of the access road, there is a car park and also the building and plot of ground devoted to agricultural technology, as well as the literary studies and general purpose buildings. As a complement to these, there is a series of blocks, arranged in parallel rows, which house the administrative offices, the art school, the craft's school, the general classrooms, and those devoted to higher education. The fascinating aspect of this school is the outstanding penetration of the architect's mind into the essential function of the project. Its most evident merit is the sense of comradeship and harmony that permeates the whole architectural manifold.Antes de construir el complejo escolar «Palos Verdes» se comenzó por crear, en el terreno, dos grandes mesetas a niveles diferentes. Sobre el inferior se organizaron: los campos de juegos, de deportes, un aparcamiento, el edificio para educación física y los destinados a tiendas y servicios. Sobre la meseta superior, al oeste de la vía de acceso, se dispuso un aparcamiento y el edificio y campo para adiestramiento agrícola; al este, otro aparcamiento, el edificio dedicado a materias literarias, y el destinado a usos múltiples. Completan las instalaciones de la escuela una serie de bloques paralelos: la administración, la escuela de arte, las clases de trabajos manuales, las aulas de enseñanzas generales, y las de los cursos superiores. Lo fascinante de este complejo escolar es la perfecta y magistral compenetración del arquitecto con el tema proyectado, y su mayor mérito, la sensación de cordialidad y armonía con el ambiente.

  16. Support to the elaboration of the engineering of detail, configuration and programming of the control system of heat removal of the TRIGA Mark III reactor

    International Nuclear Information System (INIS)

    Diaz G, C. A.

    2016-01-01

    Nowadays, the peaceful and responsible use of nuclear energy in Mexico is of great importance and contributes to economic, social, scientist and technologic development in the country, highlighting the Instituto Nacional de Investigaciones Nucleares (ININ) and the Nuclear Power Plant of Laguna Verde as one of the most important dependences. Among the main facilities and laboratories of ININ is the Nuclear Research Reactor TRIGA Mark III, this is a pool type reactor with mobile core, cooled and moderated by light water and a flow of 1013 n/cm"2/sec. Due to the technological obsolescence is a growing problem that threatens the information, operation and/or efficacy of elements of control and safety systems of the reactor, these must be changed each time more frequently. In the modernization of reactor was used a Modicon M340 programmable logic control (PLC) and a Twido PLC for the control of heat removal system (Primary Cooling System (PCS) and Secondary Cooling System (SCS) respectively), this because the PLC has proven to be safe and effective devices, addition to reduce the wiring elements and increase the possibilities of performance and design of the digital control console. This document shows and describes the elements of heat removal system (PCS and SCS), and the signals and signal types that such items send or received by the PLC, likewise, is indicated the methodology used to develop the applications for the control of the Primary Cooling System and Secondary Cooling System, beginning with the PLC design, the development of PLC plans and the control logic, and finally, the simulation and debugging of applications on Unity Pro and Twido Suite. All this in compliance with the safety standards to nuclear research reactors (NS-R-4), the rules of industrial programming (IEC 61131-3), and the reactor operating limits postulated in the safety report and the software assurance system used in the ININ. (Author)

  17. Simulation of the aspersion system of the core at high pressure (HPCS) for a boiling water reactor (BWR) based on RELAP

    International Nuclear Information System (INIS)

    Vargas O, D.; Chavez M, C.

    2012-10-01

    A high-priority topic for the nuclear industry is the safety, consequently a nuclear power plant should have the emergency systems of cooling of the core (ECCS), designed exclusively to enter in operation in the event of an accident with coolant loss, including the design base accident. The objective of the aspersion system of the core at high pressure (HPCS) is to provide in an autonomous way the cooling to the core maintaining for if same the coolant inventory even when a small break is presented that does not allow the depressurization of the reactor and also avoiding excessive temperatures that affect the shielding of the fuel. The present work describes the development of the model and the simulation of the HPCS using the RELAP/SCDAP code. During the process simulation, for the setting in march of the system HPCS in an accident with coolant loss is necessary to implement the main components of the system taking into account what unites them, the main pump, the filled pump, the suction and injection valves, pipes and its water sources that can be condensed storage tanks and the suppression pool. The simulation of this system will complement the model with which counts the Analysis Laboratory in Nuclear Reactors Engineering of the UNAM regarding to the nuclear power plant of Laguna Verde which does not have a detailed simulation of the emergency cooling systems. (Author)

  18. Palo Verde nuclear generating station EASEplus SIMULATE model

    International Nuclear Information System (INIS)

    McDonald, W.F.; Reed, M.L.; Fauste, J.L.

    1992-01-01

    The Palo Verde on-site reactor engineers have an extremely powerful and accurate tool for quickly predicting the effects of reactor power maneuvers on core axial shape index (ASI) and xenon worth. They can analyze postulated future power maneuvers quickly and supply the reactor operators with valuable predictions without having to consult with the off-site nuclear analysis group. The tool developed by the nuclear analysis group was an advanced nodal code with a graphic user interface (GUI) driver for ease of use. The advanced nodal code used was the Studsvik of America SIMULATE-3 Version 2.20-DSI. This SIMULATE version was compiled for use on a personal computer (PC) with a Definicon Systems' 50-MHz coprocessor board. The GUI face used was Expert-EASE Systems' EASE+SIM3 Version 3.0 pre-/postprocessor. The system was installed on Compaq Deskpro 386/20e PCs located in the control room of each of the three units, in the reactor engineering office, in the nuclear analysis office, and in the control room of the training simulator

  19. Talento verde y cadenas de suministro verdes: ¿existe una relación significativa?

    Directory of Open Access Journals (Sweden)

    María del Carmen Torres-Salazar

    2016-01-01

    Full Text Available Introducción: En este texto se presentan resultados estadísticos de la relación entre directivos con características de talento verde y la implementación de prácticas de cadena de suministro verde. Debido a que existen investigaciones sobre la importancia de la visión de la alta dirección para la adopción de prácticas verdes; y sin embargo ninguna da cuenta de las características personales del directivo, ni tampoco de la relación significativa entre estas características y la puesta en marcha de prácticas de cadena de suministro verde, esta es la aportación de la presente investigación. El trabajo se desarrolló en empresas manufactureras con más de diez trabajadores de la zona oriente del estado de Morelos México. La caracterización del término talento verde se reportó en el artículo, Talento verde: caracterización y búsqueda, publicado en el número 14 de esta revista. Método: El método utilizado consistió en la construcción de una encuesta dividida en tres categorías que posteriormente se convirtieron en variables: prácticas de cadena de suministro verde, presiones institucionales y talento verde. Las dos primeras se adaptaron de la encuesta de Zhu y Sarkis (2007 y la tercera surgió de la representación social de talento verde, producto de una fase de esta investigación. La encuesta se validó con un grupo de empresarios miembros de la Cámara Nacional de la Industria de la Transformación (CANACINTRA capítulo Morelos. El instrumento validado se aplicó a 26 directivos de empresas manufactureras con más de diez trabajadores de la zona oriente de Morelos, con el fin de probar la relación entre directivos con características de talento verde y la puesta en marcha de prácticas de cadena de suministro verde. Para ello se utilizaron como herramientas estadísticas la correlación de Pearson y la regresión lineal múltiple. Resultados: Las prácticas de cadena de suministro verde de las empresas

  20. 36 CFR 7.39 - Mesa Verde National Park.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Mesa Verde National Park. 7... SPECIAL REGULATIONS, AREAS OF THE NATIONAL PARK SYSTEM § 7.39 Mesa Verde National Park. (a) Visiting of... the admission of commercial automobiles and buses to Mesa Verde National Park, contained in § 5.4 of...

  1. Support to the elaboration of the engineering of detail, configuration and programming of the control system of heat removal of the TRIGA Mark III reactor; Apoyo a la elaboracion de la ingenieria de detalle, configuracion y programacion del sistema de control de remocion de calor del reactor Triga Mark III

    Energy Technology Data Exchange (ETDEWEB)

    Diaz G, C. A.

    2016-07-01

    Nowadays, the peaceful and responsible use of nuclear energy in Mexico is of great importance and contributes to economic, social, scientist and technologic development in the country, highlighting the Instituto Nacional de Investigaciones Nucleares (ININ) and the Nuclear Power Plant of Laguna Verde as one of the most important dependences. Among the main facilities and laboratories of ININ is the Nuclear Research Reactor TRIGA Mark III, this is a pool type reactor with mobile core, cooled and moderated by light water and a flow of 1013 n/cm{sup 2}/sec. Due to the technological obsolescence is a growing problem that threatens the information, operation and/or efficacy of elements of control and safety systems of the reactor, these must be changed each time more frequently. In the modernization of reactor was used a Modicon M340 programmable logic control (PLC) and a Twido PLC for the control of heat removal system (Primary Cooling System (PCS) and Secondary Cooling System (SCS) respectively), this because the PLC has proven to be safe and effective devices, addition to reduce the wiring elements and increase the possibilities of performance and design of the digital control console. This document shows and describes the elements of heat removal system (PCS and SCS), and the signals and signal types that such items send or received by the PLC, likewise, is indicated the methodology used to develop the applications for the control of the Primary Cooling System and Secondary Cooling System, beginning with the PLC design, the development of PLC plans and the control logic, and finally, the simulation and debugging of applications on Unity Pro and Twido Suite. All this in compliance with the safety standards to nuclear research reactors (NS-R-4), the rules of industrial programming (IEC 61131-3), and the reactor operating limits postulated in the safety report and the software assurance system used in the ININ. (Author)

  2. Simulation of the aspersion system of the core at high pressure (HPCS) for a boiling water reactor (BWR) based on RELAP; Simulacion del sistema de aspersion del nucleo alta presion (HPCS) para un reactor de agua en ebullicion (BWR) basado en RELAP

    Energy Technology Data Exchange (ETDEWEB)

    Vargas O, D.; Chavez M, C., E-mail: danmirnyi@gmail.com [UNAM, Facultad de Ingenieria, Circuito Interior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2012-10-15

    A high-priority topic for the nuclear industry is the safety, consequently a nuclear power plant should have the emergency systems of cooling of the core (ECCS), designed exclusively to enter in operation in the event of an accident with coolant loss, including the design base accident. The objective of the aspersion system of the core at high pressure (HPCS) is to provide in an autonomous way the cooling to the core maintaining for if same the coolant inventory even when a small break is presented that does not allow the depressurization of the reactor and also avoiding excessive temperatures that affect the shielding of the fuel. The present work describes the development of the model and the simulation of the HPCS using the RELAP/SCDAP code. During the process simulation, for the setting in march of the system HPCS in an accident with coolant loss is necessary to implement the main components of the system taking into account what unites them, the main pump, the filled pump, the suction and injection valves, pipes and its water sources that can be condensed storage tanks and the suppression pool. The simulation of this system will complement the model with which counts the Analysis Laboratory in Nuclear Reactors Engineering of the UNAM regarding to the nuclear power plant of Laguna Verde which does not have a detailed simulation of the emergency cooling systems. (Author)

  3. Hospitales reformando al mundo verde

    Directory of Open Access Journals (Sweden)

    Sandra Milene Rojas-Criollo

    2016-12-01

    Full Text Available Introducción: factores ambientales como el cambio climático, el calentamiento global, el mal uso del suelo y del agua, la mala administración de los recursos naturales, la contaminación del aire en espacios abiertos y cerrados, el crecimiento urbano y la industrialización han ocasionado cambios en los procesos naturales del planeta; para la Organización Mundial de la Salud constituyen una barrera significativa que impide alcanzar los objetivos del milenio y del desarrollo sostenible, haciendo cada vez más grave su aplicación y generando un ambiente hostil para la vida de las personas. Metodología: investigación documental, descriptiva, con enfoque cualitativo. Se realizó búsqueda en las bases de datos Ebsco, Proquest, Scielo, Elsevier, etc., con descriptores en inglés y español. Se clasificó los artículos por similitudes, autores y definiciones; se agruparon 60 artículos en una matriz y, posteriormente, se analizaron y se integraron los conceptos para luego categorizarlos. Conclusiones: es de gran relevancia el conocimiento sobre hospitales verdes, ya que son empresas que promueven la salud pública y la reducción del impacto ambiental, además de la disminución de los índices de morbilidad y mortalidad. El personal de salud tiene un papel importante para desarrollar e implementar estas actividades en beneficio del ambiente y las personas

  4. Advances in the development of the Mexican platform for analysis and design of nuclear reactors: AZTLAN Platform; Avances en el desarrollo de la plataforma mexicana para analisis y diseno de reactores nucleares: AZTLAN Platform

    Energy Technology Data Exchange (ETDEWEB)

    Gomez T, A. M.; Puente E, F. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Del Valle G, E. [IPN, Escuela Superior de Fisica y Matematicas, Av. IPN s/n, 07738 Ciudad de Mexico (Mexico); Francois L, J. L. [UNAM, Facultad de Ingenieria, Departamento de Sistemas Energeticos, Paseo Cuauhnahuac 8532, Col. Progreso, 62550 Jiutepec, Morelos (Mexico); Espinosa P, G., E-mail: armando.gomez@inin.gob.mx [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, 09340 Ciudad de Mexico (Mexico)

    2017-09-15

    The AZTLAN platform project: development of a Mexican platform for the analysis and design of nuclear reactors, financed by the SENER-CONACYT Energy Sustain ability Fund, was approved in early 2014 and formally began at the end of that year. It is a national project led by the Instituto Nacional de Investigaciones Nucleares (ININ) and with the collaboration of Instituto Politecnico Nacional (IPN), the Universidad Autonoma Metropolitana (UAM) and Universidad Nacional Autonoma de Mexico (UNAM) as part of the development team and with the participation of the Laguna Verde Nuclear Power Plant, the National Commission of Nuclear Safety and Safeguards, the Ministry of Energy and the Karlsruhe Institute of Technology (Kit, Germany) as part of the user group. The general objective of the project is to modernize, improve and integrate the neutronic, thermo-hydraulic and thermo-mechanical codes, developed in Mexican institutions, in an integrated platform, developed and maintained by Mexican experts for the benefit of Mexican institutions. Two years into the process, important steps have been taken that have consolidated the platform. The main results of these first two years have been presented in different national and international forums. In this congress, some of the most recent results that have been implemented in the platform codes are shown in more detail. The current status of the platform from a more executive view point is summarized in this paper. (Author)

  5. Characterization of welding of AISI 304l stainless steel similar to the core encircling of a BWR reactor; Caracterizacion de soldaduras de acero inoxidable AISI 304L similares a las de la envolvente del nucleo de un reactor BWR

    Energy Technology Data Exchange (ETDEWEB)

    Gachuz M, M.E.; Palacios P, F.; Robles P, E.F. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    Plates of austenitic stainless steel AISI 304l of 0.0381 m thickness were welded by means of the SMAW process according to that recommended in the Section 9 of the ASME Code, so that it was reproduced the welding process used to assemble the encircling of the core of a BWR/5 reactor similar to that of the Laguna Verde Nucleo electric plant, there being generated the necessary documentation for the qualification of the one welding procedure and of the welder. They were characterized so much the one base metal, as the welding cord by means of metallographic techniques, scanning electron microscopy, X-ray diffraction, mechanical essays and fracture mechanics. From the obtained results it highlights the presence of an area affected by the heat of up to 1.5 mm of wide and a value of fracture tenacity (J{sub IC}) to ambient temperature for the base metal of 528 KJ/m{sup 2}, which is diminished by the presence of the welding and by the increment in the temperature of the one essay. Also it was carried out an fractographic analysis of the fracture zone generated by the tenacity essays, what evidence a ductile fracture. The experimental values of resistance and tenacity are important for the study of the structural integrity of the encircling one of the core. (Author)

  6. Advances in the development of the Mexican platform for analysis and design of nuclear reactors: AZTLAN Platform

    International Nuclear Information System (INIS)

    Gomez T, A. M.; Puente E, F.; Del Valle G, E.; Francois L, J. L.; Espinosa P, G.

    2017-09-01

    The AZTLAN platform project: development of a Mexican platform for the analysis and design of nuclear reactors, financed by the SENER-CONACYT Energy Sustain ability Fund, was approved in early 2014 and formally began at the end of that year. It is a national project led by the Instituto Nacional de Investigaciones Nucleares (ININ) and with the collaboration of Instituto Politecnico Nacional (IPN), the Universidad Autonoma Metropolitana (UAM) and Universidad Nacional Autonoma de Mexico (UNAM) as part of the development team and with the participation of the Laguna Verde Nuclear Power Plant, the National Commission of Nuclear Safety and Safeguards, the Ministry of Energy and the Karlsruhe Institute of Technology (Kit, Germany) as part of the user group. The general objective of the project is to modernize, improve and integrate the neutronic, thermo-hydraulic and thermo-mechanical codes, developed in Mexican institutions, in an integrated platform, developed and maintained by Mexican experts for the benefit of Mexican institutions. Two years into the process, important steps have been taken that have consolidated the platform. The main results of these first two years have been presented in different national and international forums. In this congress, some of the most recent results that have been implemented in the platform codes are shown in more detail. The current status of the platform from a more executive view point is summarized in this paper. (Author)

  7. Characterization of welding of AISI 304l stainless steel similar to the core encircling of a BWR reactor

    International Nuclear Information System (INIS)

    Gachuz M, M.E.; Palacios P, F.; Robles P, E.F.

    2003-01-01

    Plates of austenitic stainless steel AISI 304l of 0.0381 m thickness were welded by means of the SMAW process according to that recommended in the Section 9 of the ASME Code, so that it was reproduced the welding process used to assemble the encircling of the core of a BWR/5 reactor similar to that of the Laguna Verde Nucleo electric plant, there being generated the necessary documentation for the qualification of the one welding procedure and of the welder. They were characterized so much the one base metal, as the welding cord by means of metallographic techniques, scanning electron microscopy, X-ray diffraction, mechanical essays and fracture mechanics. From the obtained results it highlights the presence of an area affected by the heat of up to 1.5 mm of wide and a value of fracture tenacity (J IC ) to ambient temperature for the base metal of 528 KJ/m 2 , which is diminished by the presence of the welding and by the increment in the temperature of the one essay. Also it was carried out an fractographic analysis of the fracture zone generated by the tenacity essays, what evidence a ductile fracture. The experimental values of resistance and tenacity are important for the study of the structural integrity of the encircling one of the core. (Author)

  8. Frequency modulator. Transmission of meteorological signals in LVC; Modulador de frecuencia. Transmision de senales meteorologicas en CLV

    Energy Technology Data Exchange (ETDEWEB)

    Rivero G, P.T.; Ramirez S, R.; Gonzalez M, J.L.; Rojas N, P.; Celis del Angel, L. [ININ, 52750 La marquesa, Estado de Mexico (Mexico)

    2007-07-01

    The development of the frequency modulator and demodulator circuit for transmission of meteorological signals by means of fiber optics of the meteorology station to the nuclear reactor unit 1 in the Laguna Verde Central in Veracruz is described. (Author)

  9. Frequency modulator. Transmission of meteorological signals in LVC

    International Nuclear Information System (INIS)

    Rivero G, P.T.; Ramirez S, R.; Gonzalez M, J.L.; Rojas N, P.; Celis del Angel, L.

    2007-01-01

    The development of the frequency modulator and demodulator circuit for transmission of meteorological signals by means of fiber optics of the meteorology station to the nuclear reactor unit 1 in the Laguna Verde Central in Veracruz is described. (Author)

  10. Reactors

    DEFF Research Database (Denmark)

    Shah, Vivek; Vaz Salles, Marcos António

    2018-01-01

    The requirements for OLTP database systems are becoming ever more demanding. Domains such as finance and computer games increasingly mandate that developers be able to encode complex application logic and control transaction latencies in in-memory databases. At the same time, infrastructure...... engineers in these domains need to experiment with and deploy OLTP database architectures that ensure application scalability and maximize resource utilization in modern machines. In this paper, we propose a relational actor programming model for in-memory databases as a novel, holistic approach towards......-level function calls. In contrast to classic transactional models, however, reactors allow developers to take advantage of intra-transaction parallelism and state encapsulation in their applications to reduce latency and improve locality. Moreover, reactors enable a new degree of flexibility in database...

  11. Verde pentru biciclete (Green for Bycicles

    Directory of Open Access Journals (Sweden)

    Romina Faur

    2011-06-01

    Full Text Available The campaign “Verde pentru biciclete” (Engl. “Green for bicycles” is the first official initiative from Timişoara that encourages adopting cycling as an ecological and economical alternative to urban transportation; this addresses the citizens of Timişoara and not only, regardless of age. “Verde pentru biciclete” is a pedalling movement supported by the Bega Foundation, in collaboration with the Gratzu Sportive Club, KissFM, Ziua de Vest, Agenda and agenda.ro. The debut of the campaign took place of October 25th 2008, with the first “Verde pentru biciclete” event – “The bicycles Counting”. All the events that followed were held to draw attention on the importance of cycling, together with obtaining of certain facilities, necessary for the cyclists’ safe movement in traffic. Moreover, a number of communication platforms have been created between the fans of cycling; thus, the website www.pedaleaza.ro has been created, through which those interested can inform themselves or communicate on the forum and discussions group verde_pentru_biciclete@yahoogroups.com o through the social network Facebook (facebook.com/ verdepentrubiciclete. This paper presents the activities held within the campaign since its beginning until today, as well as our future plans.

  12. How Palo Verde saved millions of dollars

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    In autumn 1992, Arizona Public Service adopted new project control procedures for outages at its three-unit Palo Verde PWR site, including: the switch to a PC-based environment; a new scheduling system; and the generation of improved graphics for decision making. Major cost savings were made and three further outages have now benefitted from the new systems. (author)

  13. Calculation of the neutron flux and fluence in the covering of the nucleus and the vessel of a BWR; Calculo del flujo neutronico y fluencia en la envolvente del nucleo y la vasija de un reactor nuclear BWR

    Energy Technology Data Exchange (ETDEWEB)

    Martinez C, E.; Del Valle G, E. [IPN, Escuela Superior de Fisica y Matematicas, U. P. Adolfo Lopez Mateos, Col. Lindavista, 07738 Mexico D. F. (Mexico); Longoria G, L. C., E-mail: evalle@esfm.ipn.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2011-11-15

    One of the main objectives related with the safety in any nuclear power plant, including the nuclear power plant of Laguna Verde, is to guarantee the structural integrity of the pressure vessel of the reactor. To identify and quantifying the damage caused be neutron irradiation in the vessel of any nuclear reactor, is necessary to know as much the neutron flux as the fluence that it has been receiving during their time of operation life, since the observables damages by means of tests mechanics are products of micro-structural effects, induced by neutron irradiation, therefore, is important the study and prediction of the neutron flux to have a better knowledge of the damage that are receiving these materials. In our calculation the code DORT was used, which solves the transport equation in discreet coordinates and in two dimensions (x-y, r-{theta} and r-z), in accord to the regulator guide, it requires to make and approach of the neutron flux in three dimensions by means of the Synthesis Method. Whit this method is possible to achieve a representation of the flux in 3D combining or synthesizing the calculated fluxes by DORT code in r-{theta}, r-z and r. In this work the application of the Synthesis Method is presented, according to the Regulator Guide 1.190, to determine the fluxes 3D in the interns of a BWR using three different space meshes. (Author)

  14. Determination of 137Cs and 60Co pollution in the area of the Laguna Verde Nuclear Power Plant, Mexico

    International Nuclear Information System (INIS)

    Salas Mar, Bernardo

    2015-01-01

    The project 'Radiological Analysis of Environmental Samples in the Gulf of Mexico and the coast of Quintana Roo', had the aim of identifying and quantifying anthropogenic radionuclides in environmental samples consisting of silt, sand and sea water. This paper presents the results of the radiological analysis of these samples, which was made in the multichannel system for gamma spectrometry with hyper-pure germanium detector in the Laboratory of Radiological Analysis of Environmental Samples, located at the Physics Department, Faculty of Sciences, of the Autonomous National University of Mexico (UNAM). The sampled points are along the coast of the contiguous states of Tamaulipas, Veracruz, Tabasco, Campeche, Yucatan and Quintana Roo. This paper presents the qualitative and quantitative concentrations of the main identified anthropogenic radionuclides 60 Co and 137 Cs. (authors)

  15. Determination of 137Cs and 60Co pollution in the area of the Laguna Verde Nuclear Power Plant, Mexico.

    Science.gov (United States)

    Salas Mar, Bernardo

    2015-11-01

    The project 'Radiological Analysis of Environmental Samples in the Gulf of Mexico and the coast of Quintana Roo', had the aim of identifying and quantifying anthropogenic radionuclides in environmental samples consisting of silt, sand and sea water. This paper presents the results of the radiological analysis of these samples, which was made in the multichannel system for gamma spectrometry with hyperpure germanium detector in the Laboratory of Radiological Analysis of Environmental Samples, located at the Physics Department, Faculty of Sciences, of the Autonomous National University of Mexico (UNAM). The sampled points are along the coast of the contiguous states of Tamaulipas, Veracruz, Tabasco, Campeche, Yucatan and Quintana Roo. This paper presents the qualitative and quantitative concentrations of the main identified anthropogenic radionuclides (60)Co and (137)Cs. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. AZTLAN platform: Mexican platform for analysis and design of nuclear reactors; AZTLAN platform: plataforma mexicana para el analisis y diseno de reactores nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Gomez T, A. M.; Puente E, F. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Del Valle G, E. [IPN, Escuela Superior de Fisica y Matematicas, Av. IPN s/n, Edif. 9, Col. San Pedro Zacatenco, 07738 Mexico D. F. (Mexico); Francois L, J. L.; Martin del Campo M, C. [UNAM, Facultad de Ingenieria, Departamento de Sistemas Energeticos, Paseo Cuauhnahuac 8532, 62550 Jiutepec, Morelos (Mexico); Espinosa P, G., E-mail: armando.gomez@inin.gob.mx [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco No. 186, Col. Vicentina, 09340 Mexico D. F. (Mexico)

    2014-10-15

    The Aztlan platform Project is a national initiative led by the Instituto Nacional de Investigaciones Nucleares (ININ) which brings together the main public houses of higher studies in Mexico, such as: Instituto Politecnico Nacional, Universidad Nacional Autonoma de Mexico and Universidad Autonoma Metropolitana in an effort to take a significant step toward the calculation autonomy and analysis that seeks to place Mexico in the medium term in a competitive international level on software issues for analysis of nuclear reactors. This project aims to modernize, improve and integrate the neutron, thermal-hydraulic and thermo-mechanical codes, developed in Mexican institutions, within an integrated platform, developed and maintained by Mexican experts to benefit from the same institutions. This project is financed by the mixed fund SENER-CONACYT of Energy Sustain ability, and aims to strengthen substantially to research institutions, such as educational institutions contributing to the formation of highly qualified human resources in the area of analysis and design of nuclear reactors. As innovative part the project includes the creation of a user group, made up of members of the project institutions as well as the Comision Nacional de Seguridad Nuclear y Salvaguardias, Central Nucleoelectrica de Laguna Verde (CNLV), Secretaria de Energia (Mexico) and Karlsruhe Institute of Technology (Germany) among others. This user group will be responsible for using the software and provide feedback to the development equipment in order that progress meets the needs of the regulator and industry; in this case the CNLV. Finally, in order to bridge the gap between similar developments globally, they will make use of the latest super computing technology to speed up calculation times. This work intends to present to national nuclear community the project, so a description of the proposed methodology is given, as well as the goals and objectives to be pursued for the development of the

  17. Development of a tool of probabilistic safety analysis for advanced nuclear reactors

    International Nuclear Information System (INIS)

    Hidalgo H, F.E.; Fran N, P.

    2007-01-01

    It is developing a tool to explain in a simple way in that it consists the Probabilistic Safety Analysis (APS) and at the same time to facilitate the comparison among the different designs of advanced nuclear reactors starting from their safety systems. This tool for teaching contemplates all the workspaces in an APS, but it is deepened only in what is the development of accident sequences and systems models. At the moment its have incorporated three types of advanced reactors, ABWR, ESBWR, and the HTGR and they are compared among if and with a BWR like that of Laguna Verde. This tool is carried out in Visual Basic code because it is a platform that can be used in any Windows atmosphere and for their easy programming. The system includes a tree of events developed for this purpose for a research HTGR built in Japan (HTTR) to have a point of comparison of the same one with other reactors of previous generations. It is that in the fourth generation reactors the measure of frequency of core damage doesn't make the same sense that for reactors of previous generations, which is due to its passive safety systems and its design type of the fuel, that which makes indispensable the development of another type of risk measure. The tree of events is presented for the initiator event 'the rupture of the main pipe' that causes the depressurization of the HTTR reactor. In this article it was concluded that it is necessary to evaluate the accident until reaching to the liberation of fission products that one knows in APS like an APS study level 1 and level 2 together. The final states developed starting from the possible phenomena that happen in these scenarios are presented. For this, its are considered flaws of all the mitigation systems that intervene in this accident. The tree of events developed for this work and the definition of the final states contributes to the development of as carrying out an APS for fourth generation reactors, with the purpose of developing an APS

  18. Reactor

    International Nuclear Information System (INIS)

    Fujibayashi, Toru.

    1976-01-01

    Object: To provide a boiling water reactor which can enhance a quake resisting strength and flatten power distribution. Structure: At least more than four fuel bundles, in which a plurality of fuel rods are arranged in lattice fashion which upper and lower portions are supported by tie-plates, are bundled and then covered by a square channel box. The control rod is movably arranged within a space formed by adjoining channel boxes. A spacer of trapezoidal section is disposed in the central portion on the side of the channel box over substantially full length in height direction, and a neutron instrumented tube is disposed in the central portion inside the channel box. Thus, where a horizontal load is exerted due to earthquake or the like, the spacers come into contact with each other to support the channel box and prevent it from abnormal vibrations. (Furukawa, Y.)

  19. AZTLAN platform: Mexican platform for analysis and design of nuclear reactors

    International Nuclear Information System (INIS)

    Gomez T, A. M.; Puente E, F.; Del Valle G, E.; Francois L, J. L.; Martin del Campo M, C.; Espinosa P, G.

    2014-10-01

    The Aztlan platform Project is a national initiative led by the Instituto Nacional de Investigaciones Nucleares (ININ) which brings together the main public houses of higher studies in Mexico, such as: Instituto Politecnico Nacional, Universidad Nacional Autonoma de Mexico and Universidad Autonoma Metropolitana in an effort to take a significant step toward the calculation autonomy and analysis that seeks to place Mexico in the medium term in a competitive international level on software issues for analysis of nuclear reactors. This project aims to modernize, improve and integrate the neutron, thermal-hydraulic and thermo-mechanical codes, developed in Mexican institutions, within an integrated platform, developed and maintained by Mexican experts to benefit from the same institutions. This project is financed by the mixed fund SENER-CONACYT of Energy Sustain ability, and aims to strengthen substantially to research institutions, such as educational institutions contributing to the formation of highly qualified human resources in the area of analysis and design of nuclear reactors. As innovative part the project includes the creation of a user group, made up of members of the project institutions as well as the Comision Nacional de Seguridad Nuclear y Salvaguardias, Central Nucleoelectrica de Laguna Verde (CNLV), Secretaria de Energia (Mexico) and Karlsruhe Institute of Technology (Germany) among others. This user group will be responsible for using the software and provide feedback to the development equipment in order that progress meets the needs of the regulator and industry; in this case the CNLV. Finally, in order to bridge the gap between similar developments globally, they will make use of the latest super computing technology to speed up calculation times. This work intends to present to national nuclear community the project, so a description of the proposed methodology is given, as well as the goals and objectives to be pursued for the development of the

  20. Development of a computer program of fast calculation for the pre design of advanced nuclear fuel 10 x 10 for BWR type reactors

    International Nuclear Information System (INIS)

    Perusquia, R.; Montes, J.L.; Ortiz, J.J.

    2005-01-01

    In the National Institute of Nuclear Research (ININ) a methodology is developed to optimize the design of cells 10x10 of assemble fuels for reactors of water in boil or BWR. It was proposed a lineal calculation formula based on a coefficients matrix (of the change reason of the relative power due to changes in the enrichment of U-235) for estimate the relative powers by pin of a cell. With this it was developed the computer program of fast calculation named PreDiCeldas. The one which by means of a simple search algorithm allows to minimize the relative power peak maximum of cell or LPPF. This is achieved varying the distribution of U-235 inside the cell, maintaining in turn fixed its average enrichment. The accuracy in the estimation of the relative powers for pin is of the order from 1.9% when comparing it with results of the 'best estimate' HELIOS code. With the PreDiCeldas it was possible, at one minimum time of calculation, to re-design a reference cell diminishing the LPPF, to the beginning of the life, of 1.44 to a value of 1.31. With the cell design with low LPPF is sought to even design cycles but extensive that those reached at the moment in the BWR of the Laguna Verde Central. (Author)

  1. Achieving engineering excellence at Palo Verde

    International Nuclear Information System (INIS)

    Prawlocki, F.C.

    1989-01-01

    Early in 1988, the management of the newly formed Palo Verde Nuclear Generating Station (PVNGS) Engineering and Construction Division was faced with a dilemma: how to build a competent, confident, efficient engineering organization in the face of increasing requirements and tightened fiscal controls. This paper discusses steps taken by Palo Verde to address actions taken to effect a smooth transition from construction to operations and the development of the Engineering Excellence Program. The Engineering Excellence Program will continue to evolve over time as the number of the NED's [Nuclear Engineering Department] personnel grown and processes are changed over the course of the next few years. As tasks from the Engineering Excellence Program action plan are completed, the results achieved are expected to be integrated into the routine business of the NED

  2. Technical specifications, Palo Verde Nuclear Generating Station, Unit No. 2 (Docket No. 50-529). Appendix A to License No. NPF-51

    International Nuclear Information System (INIS)

    1986-04-01

    Information is presented concerning the technical specifications for the Palo Verde-2 Reactor. Areas of interest discussed in this report include: safety limits and limiting safety system settings; limiting conditions for operation and surveillance requirements; design features; and administrative controls. 19 figs., 62 tabs

  3. Palo Verde receives new control room simulator

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    A new control room simulator was delivered to Arizona Public Service Company's Palo Verde nuclear generating station in late August. The system, the second simulator on site, will be used for training beginning in January 1994, said David C. Brown, manager of the simulator upgrade project. Having two simulators will ease the current tight training schedule, and allow expansion of instruction to personnel other than licensed operators

  4. QUÍMICA VERDE: UN NUEVO RETO

    Directory of Open Access Journals (Sweden)

    Nerlis Paola Pájaro Castro

    2011-01-01

    Full Text Available En la actualidad, existe un enorme deterioro del medio ambiente que ha generado la necesidad de buscar alternativas que conduzcan a la sostenibilidad ambiental. Una de estas herramientas es la ¿química verde¿, concepto que contempla el diseño de productos y procesos que reduzcan la generación de sustancias peligrosas y maximicen la eficiencia en la utilización de recursos materiales y energéticos. El empleo de tecnologías menos contaminantes, permitirá a las empresas químicas mitigar los efectos ambientales asociados a su actividad, reduciendo el consumo de materiales e incrementando la participación de recursos renovables. Para alcanzar estas metas, se han propuesto 12 principios básicos de química verde, aplicables en diferentes campos, tales como la medicina, la agricultura, la industria química y farmacéutica. Esta revisión detalla los principios y usos principales de la química verde, y su aplicación como una filosofía de trabajo para avanzar hacia un verdadero desarrollo sostenible.

  5. Impact of Sahara dust transport on Cape Verde atmospheric element particles.

    Science.gov (United States)

    Almeida-Silva, M; Almeida, S M; Freitas, M C; Pio, C A; Nunes, T; Cardoso, J

    2013-01-01

    The objectives of this study were to (1) conduct an elemental characterization of airborne particles sampled in Cape Verde and (2) assess the influence of Sahara desert on local suspended particles. Particulate matter (PM(10)) was collected in Praia city (14°94'N; 23°49'W) with a low-volume sampler in order to characterize its chemical composition by k0-INAA. The filter samples were first weighed and subsequently irradiated at the Portuguese Research Reactor. Results showed that PM(10) concentrations in Cape Verde markedly exceeded the health-based air quality standards defined by the European Union (EU), World Health Organization (WHO), and U.S. Environmental Protection Agency (EPA), in part due to the influence of Sahara dust transport. The PM(10) composition was characterized essentially by high concentrations of elements originating from the soil (K, Sm, Co, Fe, Sc, Rb, Cr, Ce, and Ba) and sea (Na), and low concentrations of anthropogenic elements (As, Zn, and Sb). In addition, the high concentrations of PM measured in Cape Verde suggest that health of the population may be less affected compared with other sites where PM(10) concentrations are lower but more enriched with toxic elements.

  6. Development of a computer program of fast calculation for the pre design of advanced nuclear fuel 10 x 10 for BWR type reactors; Desarrollo de un program de computo de calculo rapido para el prediseno de celdas de combustible nuclear avanzado 10 x 10 para reactores de agua en ebullicion

    Energy Technology Data Exchange (ETDEWEB)

    Perusquia, R.; Montes, J.L.; Ortiz, J.J. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: mrpc@nuclear.inin.mx

    2005-07-01

    In the National Institute of Nuclear Research (ININ) a methodology is developed to optimize the design of cells 10x10 of assemble fuels for reactors of water in boil or BWR. It was proposed a lineal calculation formula based on a coefficients matrix (of the change reason of the relative power due to changes in the enrichment of U-235) for estimate the relative powers by pin of a cell. With this it was developed the computer program of fast calculation named PreDiCeldas. The one which by means of a simple search algorithm allows to minimize the relative power peak maximum of cell or LPPF. This is achieved varying the distribution of U-235 inside the cell, maintaining in turn fixed its average enrichment. The accuracy in the estimation of the relative powers for pin is of the order from 1.9% when comparing it with results of the 'best estimate' HELIOS code. With the PreDiCeldas it was possible, at one minimum time of calculation, to re-design a reference cell diminishing the LPPF, to the beginning of the life, of 1.44 to a value of 1.31. With the cell design with low LPPF is sought to even design cycles but extensive that those reached at the moment in the BWR of the Laguna Verde Central. (Author)

  7. Simulation of the fault transitory of the feedwater controller in a Boiling water reactor with the Ramona-3B code; Simulacion del transitorio de falla del controlador de agua de alimentacion en un reactor de agua en ebullicion con el codigo RAMONA-3B

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez M, J.L.; Ortiz V, J. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-07-01

    The obtained results when carrying out the simulation of the fault transitory of the feedwater controller (FCAA) with the Ramona-3B code, happened in the Unit 2 of the Laguna Verde power plant (CNLV), in September of the year 2000 are presented. The transitory originates as consequence of the controller's fault of speed of a turbo pump of feedwater. The work includes a short description of the event, the suppositions considered for the simulation and the obtained results. Also, a discussion of the impact of the transitory event is presented on aspects of reactor safety. Although the carried out simulation is limited by the capacities of the code and for the lack of available information, it was found that even in a conservative situation, the power was incremented only in 12% above the nominal value, while that the thermal limit determined by the minimum reason of the critical power, MCPR, always stayed above the limit values of operation and safety. (Author)

  8. Intraplate seismicity across the Cape Verde swell

    Science.gov (United States)

    Vales, Dina; Matias, Luís.; Haberland, Christian; Silveira, Graça.; Weber, Michael; Carrilho, Fernando; Dias, Nuno

    2010-05-01

    The Cape Verde Archipelago ((15-17°N, 23-26°W) is located within the African plate, about 500km west of Senegal, in the African coast. The islands are located astride the Cape Verde mid-plate topographic swell, one of the largest features of its type in the world's ocean basins. The origin of this Cape Verde swell is still in debate. Previous determinations of the elastic thickness (Te) reveal a normal Te and a modest heat flow anomaly which suggest that the swell cannot be fully explained by uplift due to thermal reheating of the lithosphere by an underlying ‘‘hot spot'' and that other, deep-seated, mantle processes must be involved. The CV-PLUME (An investigation on the geometry and deep signature of the Cape Verde mantle plume) project intends to shape the geometry and deep origin of the Cape Verde mantle plume, via a combined study of seismic, magnetic, gravimetric and geochemical observations. Through this study we intend to characterize the structure beneath the archipelago from the surface down to the deep mantle. The core of this 3-year project was a temporary deployment of 39 Very Broad Band seismometers, across all the inhabited islands, to recorder local and teleseismic earthquakes. These instruments were operational from November 2007 to September 2008. In this work we report on the preliminary results obtained from the CV-PLUME network on the characterization of the local and regional seismicity. To detect the small magnitude seismic events the continuous data stream was screened using spectrograms. This proved to be a very robust technique in the face of the high short-period noise recorded by many of the stations, particularly during day time. The 10 month observation time showed that the background seismic activity in the Archipelago and surrounding area is low, with only a very few events recorded by the complete network. However, two clusters of earthquakes were detected close to the Brava Island, one to the NW and a second one, more active

  9. Decontamination and disposal of Sb-124 at Palo Verde Nuclear Generating Station

    International Nuclear Information System (INIS)

    Miller, A.D.; Hillmer, T.P.; Kester, J.W.; Hensch, J.R.

    1988-01-01

    Palo Verde Nuclear Generating Station (PVNGS) is a three unit Combustion Engineering pressurized water reactor site. Each unit consists of an identical, self contained 1270 MWe reactor. This standardized design allows sharing of design improvements and equipment leading to optimum operation of the individual units. One design improvement, identified early into the operation of Unit 1, involved the elemental antimony content of the seals and bearings within the reactor coolant pumps. Normal wear of these components releases small amounts of elemental antimony. This antimony in turn deposits on in-core surfaces and activates to produce the isotopes Sb-122 and Sb-124. These isotopes emit highly energetic gamma rays which contribute significantly to the exposure and radwaste disposal charges at PVNGS. For these reasons, the Antimony Removal Program was undertaken to remove the radioactive and elemental antimony from the nuclear steam supply system at all three units. The work presented here describes the antimony decontamination and disposal

  10. Design and axial optimization of nuclear fuel for BWR reactors

    International Nuclear Information System (INIS)

    Garcia V, M.A.

    2006-01-01

    In the present thesis, the modifications made to the axial optimization system based on Tabu Search (BT) for the axial design of BWR fuel type are presented, developed previously in the Nuclear Engineering Group of the UNAM Engineering Faculty. With the modifications what is mainly looked is to consider the particular characteristics of the mechanical design of the GE12 fuel type, used at the moment in the Laguna Verde Nucleo electric Central (CNLV) and that it considers the fuel bars of partial longitude. The information obtained in this thesis will allow to plan nuclear fuel reloads with the best conditions to operate in a certain cycle guaranteeing a better yield and use in the fuel burnt, additionally people in charge in the reload planning will be favored with the changes carried out to the system for the design and axial optimization of nuclear fuel, which facilitate their handling and it reduces their execution time. This thesis this developed in five chapters that are understood in the following way in general: Chapter 1: It approaches the basic concepts of the nuclear energy, it describes the physical and chemical composition of the atoms as well as that of the uranium isotopes, the handling of the uranium isotope by means of the nuclear fission until arriving to the operation of the nuclear reactors. Chapter 2: The nuclear fuel cycle is described, the methods for its extraction, its conversion and its enrichment to arrive to the stages of the nuclear fuel management used in the reactors are described. Beginning by the radial design, the axial design and the core design of the nuclear reactor related with the fuel assemblies design. Chapter 3: the optimization methods of nuclear fuel previously used are exposed among those that are: the genetic algorithms method, the search methods based on heuristic rules and the application of the tabu search method, which was used for the development of this thesis. Chapter 4: In this part the used methodology to the

  11. Camp Verde Adult Reading Program. Final Performance Report.

    Science.gov (United States)

    Maynard, David A.

    This document begins with a four-page performance report describing how the Camp Verde Adult Reading Program site was relocated to the Community Center Complex, and the Town Council contracted directly with the Friends of the Camp Verde Library to provide for the requirements of the program. The U.S. Department of Education grant allowed the…

  12. ASPECTOS HIDROLOGICOS DE LAS LAGUNAS DE ATASTA Y POM, MEXICO

    Directory of Open Access Journals (Sweden)

    Alejandro Ruiz-Marín

    2009-01-01

    Full Text Available Las lagunas de Pom y Atasta forman parte del área natural protegida de flora y fauna laguna de Términos en la región de Campeche, México. Esta es una  importante área ecológica ya que es el habitad de muchas especies nativas y migratorias. Estas lagunas han sido afectadas por actividades industriales y por descargas de aguas residuales. Monitoreo de nitrógeno, fósforo y coliformes fecales en agua superficial fueron realizados a lo largo de ambas lagunas durante las temporadas de seca, lluvia y nortes durante un año. Las altas temperaturas en verano (31 ºC y mínimas en nortes (25ºC fueron asociadas con valores de oxigeno disuelto (5.1 y 6.3 mg l-1, respectivamente indicando también una probable relación con la actividad fitoplanctonica. El pH (8.0-8.2 y la salinidad (0.32 - 3.48 UPS no mostraron variación significativa entre las tres temporadas climáticas. El nivel de amonio no fue mayor a los valores sugeridos para el control de eutroficación (0.1 mg l-1, mientras que los niveles de fósforo fueron de mayor concentración (2.0-3.5 mg l-1 que aquellos considerados seguros (0.01-0.125 mg l-1 para el medio ambiente. Las más altas concentraciones de N y P cerca de las áreas habitadas sugiere un importante contribución de nutrientes provenientes de aguas de desecho, asociado con la descomposición de material orgánico. La concentración de coliformes fecales durante la temporada de lluvias y nortes (8.0-26.0 MPN 100 ml-1 fue mayor que durante la temporada de seca (1.3-3.5 MPN 100 ml-1 sugiriendo un importante acceso por escurrimiento pluvial y aguas residuales no tratadas proveniente de las áreas cercanas al lago habitadas. La deforestación de manglares y la descontrolada actividad de agricultura afectaran la calidad del agua en ambos lagos en el futuro.

  13. High-$\\gamma$ Beta Beams within the LAGUNA design study

    CERN Document Server

    Orme, Christopher

    2010-01-01

    Within the LAGUNA design study, seven candidate sites are being assessed for their feasibility to host a next-generation, very large neutrino observatory. Such a detector will be expected to feature within a future European accelerator neutrino programme (Superbeam or Beta Beam), and hence the distance from CERN is of critical importance. In this article, the focus is a $^{18}$Ne and $^{6}$He Beta Beam sourced at CERN and directed towards a 50 kton Liquid Argon detector located at the LAGUNA sites: Slanic (L=1570 km) and Pyh\\"{a}salmi (L=2300 km). To improve sensitivity to the neutrino mass ordering, these baselines are then combined with a concurrent run with the same flux directed towards a large Water \\v{C}erenkov detector located at Canfranc (L=650 km). This degeneracy breaking combination is shown to provide comparable physics reach to the conservative Magic Baseline Beta Beam proposals. For $^{18}$Ne ions boosted to $\\gamma=570$ and $^{6}$He ions boosted to $\\gamma=350$, the correct mass ordering can be...

  14. Condiciones sedimentológicas de la laguna la restinga, isla de margarita, venezuela

    OpenAIRE

    C, Julio; Salazar, L; A, Jesús; C, Rosas; C, Julio; Rodríguez, R

    2003-01-01

    Resumen La laguna La Restinga, en el sureste del Mar Caribe, es una laguna costera que comprende pequeñas lagunas rodeadas de manglares, conformando el sistema lagunar más importante de la Isla de Margarita. Se comunica con el mar, al sur, a través de una boca de 800m de largo, 80-100m de ancho y profundidad promedio de 6m. Está separada del mar, al norte, por un istmo o restinga de 23,5km, y sus drenajes naturales se evidencian solamente en la época de lluvia. Se estudiaron algunos aspectos ...

  15. A novel feedwater system for the RETRAN model of the Palo Verde nuclear generating station

    International Nuclear Information System (INIS)

    Secker, P.A.; Webb, J.R.

    1988-01-01

    This paper presents a feedwater system model which supplies realistic boundary conditions to the RETRAN model of a Palo Verde Nuclear Generating Station reactor plant. The RETRAN thermal hydraulic code is used to analyze nuclear reactor system transients through a generalized thermal hydraulic volume/junction network. The feedwater system model is implemented using the control block modeling option available in the RETRAN code. The output of the control block model is coupled to the thermal hydraulic network by a fill junction. A forward Euler integration scheme is used by RETRAN for control block variables. The feedwater system model is formulated to allow implicit integration within the existing code framework. The potential need for small integration time steps is, therefore, alleviated. The model results are compared with test data

  16. Determination of the exposition rapidity in the level 49.90 of the reactor building for the decrease in the water level of the spent fuel pool

    International Nuclear Information System (INIS)

    Mijangos D, Z. E.; Herrera H, S. F.; Cruz G, M. A.; Amador C, C.

    2014-10-01

    The fuel assemblies storage in the nuclear power plant of Laguna Verde (NPP-L V) represents a crucial aspect, due to the generated dose by the decay heat of the present radio-nuclides in the assemblies retired of the reactor core, after their useful life. These spent assemblies are located inside the spent fuel pool (SFP), in the level 49.90 m in the Reload Floor of the Reactor building of NPP-L V. This leads to the protection at personnel applying the ALARA (As Low As Reasonably Achievable) criteria, fulfilling the established dose criteria by the Regulator Body the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS). Considering the loss scenario of the cooling system of the SFP, in which the SFP water vaporizes, is important to know the water level in which the limit of effective dose equivalent is fulfilled for the personnel. Also, is important for the instrumentation of the SFP, for the useful life of the same instruments. In this work is obtained the exposition rapidity corresponding to different water levels of SFP in the Reload Floor of NPP-L V, to identify the minimum level of water where the limit of effective dose equivalent is fulfilled of 25 rem s to the personnel, established in the Article 48 of the General Regulation of Radiological Safety of CNSNS and the Chapter 50 Section 67 of the 10-Cfr of Nuclear Regulatory Commission in USA. The water level is also identified where the exposition rapidity is of 15 m R/hr, being the value of the set point of the area radiation monitor D21-Re-N003-1, located to 125 cm over the level 49.90 meters of the Reload Floor of NPP-L V. (Author)

  17. History and current safety measures at Laguna Palcacocha, Huaraz, Peru

    Science.gov (United States)

    Salazar Checa, César; Cochachin, Alejo; Frey, Holger; Huggel, Christian; Portocarrero, César

    2017-04-01

    Laguna Palcacocha is a large glacier lake in the Cordillera Blanca, Peru, located in the Quillcay catchment, above the city of Huaraz, the local capital. On 13 December 1941, the moraine dam lake collapsed, probably after having been impacted by a large ice avalanche, and triggered a major outburst flood. This GLOF destroyed about a third of the city of Huaraz, causing about 2,000 casualties and is therefore one of the deadliest glacier lake outbursts known in history. In 1974, the Glaciology Unit of Peru, responsible for the studying, monitoring and mitigation works related to glacier hazards installed a reinforcement of the natural moraine dam of the newly filled Laguna Palcacocha, with an artificial drainage channel at 7 m below the crest of the reinforced dam. At that time, the lake had an area of 66,800 m2 and a volume of 0.5 x 106 m3. During the past decades, in the course of continued glacier retreat, Laguna Palcacocha has undergone an extreme growth. In February 2016, the lake had an area of 514,000 m2 (7.7 times the area of 1974) and a volume of more than 17 x 106 m3 (more than 34 times the volume of 1974). At the same time, the city of Huaraz, located 20 km downstream of the lake, grew significantly after its almost complete destruction by the 1970 earthquake. Today, about 120,000 people are living in the city. Due to the persisting possibility for large ice avalanches directly above the Palcacocha lake, this constitutes a high-risk situation, requiring new hazard and risk mitigation measures. As an immediate temporal measure, in order to bridge the time until the realization of a more permanent measure, a syphoning system has been installed in 2011, using about ten 700-m pipes with a 10-inch (25.4 cm) diameter. The aim of this syphoning attempt is to lower the lake level by about 7 m, and therefore reduce the lake volume on the one hand, and also reach a higher dam freeboard. However, the system is less effective than assumed, currently the lake level

  18. Laguna Madre Water Purification using Biochar from Citrus Peels

    Science.gov (United States)

    Lopez, C.; Al-Qudah, O. M.

    2017-12-01

    Laguna Madre is an important lagoon in the coast of Texas. It is one of the seven hypersaline lagoons in the world. Due to inflow of water with extreme amounts of phosphorus and nitrates and the low inflow of freshwater, the lagoon has high amount of phosphorus and nitrates which can be harmful for fish and plants situated in the lagoon. The goal is to be able to perform a filtration method with citrus peels biochar, and then to evaluate and compare the produced biochar, zeolite, and activated carbon as an infiltration filter by assessing reductions of nitrogen and phosphorus compounds, as well as sum selected trace elements. Furthermore, the current research will investigate how long the cleaning capacity of biochar lasts and how the performance of the filter changes under an increased load of contaminants. The performance of biochar from different parent materials and recycling options for the used filter materials are also included in this research.

  19. GRIP BARBADOS/CAPE VERDE RADIOSONDE V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Barbados/Cape Verde radiosonde data set consists of generally two soundings per day (06Z and 12Z) launched from Barbados, and one sounding per day (12Z)...

  20. New species of mayflies (Ephemeroptera) from Cape Verde

    Czech Academy of Sciences Publication Activity Database

    Soldán, Tomáš; Bojková, J.

    2015-01-01

    Roč. 3926, č. 4 (2015), s. 561-575 ISSN 1175-5326 Institutional support: RVO:60077344 Keywords : Cape Verde * Macaronesia * West Africa Subject RIV: EH - Ecology, Behaviour Impact factor: 0.994, year: 2015

  1. Palo Verde Unit 3 BMI nozzle modification

    International Nuclear Information System (INIS)

    Waskey, D.

    2015-01-01

    The 61 BMI (Bottom Mount Instrumentation) nozzles of the unit 3 of the Palo Verde plant have been examined through ASME Code Case N722. The nozzle 3 was the only one with leakage noted. The ultrasound testing results are characteristic of PWSCC (Primary Water Stress Corrosion Cracking). The initiation likely occurred at a weld defect which was exposed to the primary water environment resulting in PWSCC. All other nozzles (60) showed no unacceptable indications. Concerning nozzle 3 one crack in J-groove weld connected large defect to primary water. An environmental model has been used to simulate and optimize the repair. The AREVA crew was on site 18 days after contract award and the job was completed in 12 days, 30 hours ahead of baseline schedule. This series of slides describes the examination of the BMI nozzles, the repair steps, and alternative design concepts

  2. Impuestos verdes: una meta de equidad

    Directory of Open Access Journals (Sweden)

    Lilliana Arrieta Quesada

    2011-09-01

    Full Text Available Al considerar necesario incorporar a los grupos económicos en el gran proyecto de alcanzar metas de desarrollo sostenible, que surge como un nuevo paradigma al tomarse en consciencia por parte de los organismos internacionales, entre ellos las Naciones Unidas, de la necesidad de hacer un planteamiento de desarrollo económico diferente al convencional que considera aspectos ambientales y de equidad social, se admite por primera vez que la explotación de los recursos naturales y su transformación en materia prima y fuente energética, tiene límites, los cuales deben ser considerados en cualquier planteamiento serio de desarrollo económico.Es así como surge la tesis de los impuestos verdes como una opción que permita a los gobiernos incidir tanto en el mercado como en el sector industrial y en los hábitos de los consumidores.

  3. Verdes Mares: The Ideology of the Siren

    Directory of Open Access Journals (Sweden)

    Bruno Marinoni Marinoni

    2009-02-01

    Full Text Available The television channel number 10 of Fortaleza (current TV Verdes Mares, during the 1960 decade, passed through the ideological filter of the Military Dictatorship, when the channel was taken from its owner and given to the businessman Edson Queiroz. The filter had consequences in the next decade with the channel affiliation to the biggest network broadcasting of the country, the Rede Globo, which was also protected by the Military Regime. Based on those two facts, it is intended to discuss some aspects of the exploration models of communication that occurs in the country since the specified period, emphasizing the ideology transmitted by the TV channel which has the biggest audience ratings in Ceará.

  4. Leptospira interrogans in Rodents from Cape Verde.

    Science.gov (United States)

    Plata-Luis, Josué; Foronda, Pilar; Martín-Alonso, Aaron; Feliu, Carlos; Alves, Joana; Gil, Horacio; Valladares, Basilio

    2016-11-01

    Leptospirosis is an important worldwide zoonotic disease that can infect both animals and humans. In most cases, leptospirosis is a nonspecific self-limiting illness, but some patients can develop a severe form with a high mortality. This study was carried out in Santiago Island, Cape Verde, in 2012-2013. A total of 62 wild rodents (Rattus rattus and Mus domesticus) were analyzed. The lipL32 gene, present only in pathogenic Leptospira spp., was amplified by PCR, and 16 samples were positive (25.8%). In both rodent species, Leptospira interrogans was identified. The results show the presence of pathogenic Leptospira in the three localities analyzed in Santiago. The presence of L. interrogans demonstrates a serious health risk for the population, since this species has been associated with the most severe form of leptospirosis, the Weil's disease in humans, a severe infection with jaundice, renal failure, and hemorrhage.

  5. Mercadeo verde de una empresa dorada

    Directory of Open Access Journals (Sweden)

    Carlos Mario Uribe-Saldarriaga

    2014-01-01

    Full Text Available El caso presenta la campaña de mercadeo realizada por Ecopetrol entre 2009 y 2012 para la introducción en Colombia del diésel ultra bajo de azufre denominado diésel limpio. Se examina la campaña desde 2 puntos de vista: el primero, el posicionamiento de Ecopetrol como una de las empresas más admiradas de Colombia, tanto por sus resultados financieros como por sus actividades en la responsabilidad social empresarial; el segundo, desde las exigencias que se hacen al mercadeo ambiental en los países desarrollados, especialmente con respecto al lavado verde, teniendo en cuenta a la vez que Ecopetrol opera en un país en vía de desarrollo donde existe un menor avance en las exigencias ambientales hechas por los grupos de interés.

  6. Mercadeo verde de una empresa dorada

    Directory of Open Access Journals (Sweden)

    Carlos Mario Uribe-Saldarriaga

    2014-01-01

    Full Text Available El caso presenta la campa ̃ na de mercadeo realizada por Ecopetrol entre 2009 y 2012 para la introducción en Colombia del diésel ultra bajo de azufre denominado diésel limpio. Se examina la campa ̃ na desde 2 puntos de vista: el primero, el posicionamiento de Ecopetrol como una de las empresas más admiradas de Colombia, tanto por sus resultados financieros como por sus actividades en la responsabilidad social empresarial; el segundo, desde las exigencias que se hacen al mercadeo ambiental en los países desarro- llados, especialmente con respecto al lavado verde, teniendo en cuenta a la vez que Ecopetrol opera en un país en vía de desarrollo donde existe un menor avance en las exigencias ambientales hechas por los grupos de interés.

  7. AMIDO RESISTENTE EM FARINHAS DE BANANA VERDE

    Directory of Open Access Journals (Sweden)

    Dayana Portes RAMOS

    2010-03-01

    Full Text Available

    Este trabalho teve por objetivo avaliar o teor de amido resistente (AR em farinhas de banana verde produzidas a partir de treze genótipos de bananeira. Para a produção da farinha foram separadas a 1ª, 3ª e 5ª pencas de cada genótipo, na qual cada penca correspondeu a uma repetição. Os frutos de cada penca no estádio 1 (casca completamente verde de maturação foram descascados manualmente, cortados em fatias circulares de 0,5 cm e desidratados em estufa com circulação de ar a 40ºC por 48 horas, sendo em seguida moídos. A análise de AR consistiu em um processo enzimático, calculando-se o conteúdo final pela concentração de glicose liberada. Os resultados foram submetidos à análise estatística e mostraram diferenças significativas para o teor de AR nas farinhas obtidas dos genótipos de bananeira, sendo que a farinha com maior teor de AR foi a produzida a partir do cultivar ‘Nam’ (40,25% e a menor pelo híbrido ‘Fhia 01’ (10,01%. Pode-se concluir que o conteúdo de AR varia em relação ao genótipo utilizado para a confecção da farinha e que a banana pode ser uma boa opção de estudo de alimento funcional.

  8. Inventario nacional de lagunas y represamientos: segunda aproximación

    OpenAIRE

    Oficina Nacional de Evaluación de Recursos Naturales

    1980-01-01

    Contiene el inventario de las lagunas y represamientos existentes en el territorio nacional, destinado a establecer la capacidad física de regulación de los ríos del país. El inventario comprende un listado y descripción sistemática de las lagunas y represamientos en explotación, en estudios o sin uso.

  9. Botanical ecology and conservation of the laguna de la herrera (sabana de bogotá, colombia)

    OpenAIRE

    Wijninga, V. M.; Rangel, Orlando; Cleef, A. M.

    2012-01-01

    Se estudió la vegetación alrededor de la Laguna de La Herrera, una laguna andina a 2550 m. Se diferenciaron una comunidad de Phytolacca bogotensis (1): comunidades helofíticas dominadas por: Scirpus californicus y Typha angustifolia (2); Scirpus californicus (3); Polygonum punctatum (4); Rumex obtusifolius y Polygonum punctatum (5); Bidens laevis (6); Hydrocotyle ranunculoides (7); comunidades pleustofíticas con: Limnobium laevigatum; (8); Azolla filiculoides y Lemna cf. gibba (9) y Eichhorni...

  10. Algorithms bio-inspired for the pattern obtention of control bars in BWR reactors

    International Nuclear Information System (INIS)

    Ortiz, J.J.; Perusquia, R.; Montes, J.L.

    2003-01-01

    In this work methods based on Genetic Algorithms and Systems based on ant colonies for the obtention of the patterns of control bars of an equilibrium cycle of 18 months for the Laguna Verde nuclear power station are presented. A comparison of obtained results with the methods and with those of design of such equilibrium cycle is presented. As consequence of the study, it was found that the algorithm based on the ant colonies reached to diminish the coast down period (decrease of power at the end of the cycle) in five and half days with respect to the original design what represents an annual saving of $US 100,000. (Author)

  11. Verde Macael: A Serpentinite Wrongly Referred to as a Marble

    OpenAIRE

    Navarro, Rafael; Pereira, Dolores; Gimeno, Ana; Barrio, Santiago

    2013-01-01

    Serpentinites are used in both exterior and interior locations, but not all serpentinites are equal: they vary in physical-mechanical behavior and are not all suitable for similar uses. The serpentinites most commonly used worldwide come from India, Pakistan or Egypt. Spain has traditionally quarried two ultramafic massifs, one in Galicia (Verde Pirineos) and one in Andalucía (Verde Macael). Some of these quarries were small family-run businesses. In both cases, these rocks are commercially a...

  12. Indice fisicoquímico de la calidad de agua para el manejo de lagunas tropicales de inundación

    Directory of Open Access Journals (Sweden)

    Ana Gabriela Pérez-Castillo

    2008-12-01

    Full Text Available Se creó un índice fisicoquímico de calidad del agua (ICA-L, para lagunas que se desbordan, el cual fue validado en el sector de riego de Tamarindo, y en una sección del sistema de lagunas del Parque Nacional Palo verde (Guanacaste, Costa Rica. El índice incluye las variables: porcentaje de saturación de oxígeno disuelto, pH, concentración de nitratos, concentración de fósforo total, demanda química de oxígeno, concentración de sólidos suspendidos, conductividad eléctrica y temperatura. El índice se fija automáticamente en cero si la concentración de alguna sustancia tóxica excede el máximo permitido. Los factores de ponderación se ajustaron con base en los pesos definidos en el Índice de Calidad de Agua de la National Sanitation Foundation (ICA-NSF, se excluyó el peso del conteo de coliformes fecales, se integró la ponderación de turbiedad y de sólidos totales una sola, de sólidos suspendidos, y se asignó a la conductividad un factor de 0.08. El índice per-mite evaluar la capacidad del agua de las lagunas tropicales de inundación de agua dulce, para lograr el sostenimiento de la biodiversidad y el desarrollo de la vida acuática, cuando surgen peligros por prácticas agropecuarias.Physicochemical water quality index, a management tool for tropical-flooding lagoons. We propose ICA-L, a wetland physicochemical water quality index (WWQI, to be used as a management tool for seasonal-flooding lagoons in Palo verde National Park, Guanacaste, Costa Rica. The goal is to preserve their natural role for native plants as well as migrants and local animal species. The index was developed in four steps: parameter selection, assignment of parameter weight, transformation of data to their corresponding sub indices and selection of an appropriate aggregation function. In this process, the following criteria were used as a reference: WQI from the National Sanitation Foundation, WQI for the Des Moines River, Escribano and De Frutos

  13. Determination of the exposition rapidity in the level 49.90 of the reactor building for the decrease in the water level of the spent fuel pool; Determinacion de la rapidez de exposion en el nivel 49.90 del edificio del reactor por la disminucion en el nivel de agua de la alberca de combustible gastado

    Energy Technology Data Exchange (ETDEWEB)

    Mijangos D, Z. E.; Herrera H, S. F.; Cruz G, M. A.; Amador C, C., E-mail: zoedelfin@gmail.com [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Subgerencia de Ingenieria, Km 44.5 Carretera Cardel-Nautla, 91476 Laguna Verde, Alto Lucero, Veracruz (Mexico)

    2014-10-15

    The fuel assemblies storage in the nuclear power plant of Laguna Verde (NPP-L V) represents a crucial aspect, due to the generated dose by the decay heat of the present radio-nuclides in the assemblies retired of the reactor core, after their useful life. These spent assemblies are located inside the spent fuel pool (SFP), in the level 49.90 m in the Reload Floor of the Reactor building of NPP-L V. This leads to the protection at personnel applying the ALARA (As Low As Reasonably Achievable) criteria, fulfilling the established dose criteria by the Regulator Body the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS). Considering the loss scenario of the cooling system of the SFP, in which the SFP water vaporizes, is important to know the water level in which the limit of effective dose equivalent is fulfilled for the personnel. Also, is important for the instrumentation of the SFP, for the useful life of the same instruments. In this work is obtained the exposition rapidity corresponding to different water levels of SFP in the Reload Floor of NPP-L V, to identify the minimum level of water where the limit of effective dose equivalent is fulfilled of 25 rem s to the personnel, established in the Article 48 of the General Regulation of Radiological Safety of CNSNS and the Chapter 50 Section 67 of the 10-Cfr of Nuclear Regulatory Commission in USA. The water level is also identified where the exposition rapidity is of 15 m R/hr, being the value of the set point of the area radiation monitor D21-Re-N003-1, located to 125 cm over the level 49.90 meters of the Reload Floor of NPP-L V. (Author)

  14. Chemistry technician performance evaluation program Palo Verde Nuclear Generating Station

    International Nuclear Information System (INIS)

    Shawver, J.M.

    1992-01-01

    The Arizona Nuclear Power Project (ANPP), a three-reactor site located 50 miles west of Phoenix, Arizona, has developed and implemented a program for evaluating individual chemistry technician analytical performance on a routine basis. About 45 chemistry technicians are employed at the site, 15 at each operating unit. The technicians routinely perform trace level analyses for impurities of concern to PWRs. Each month a set of blind samples is provided by an outside vendor. The blind samples contain 16 parameters which are matrixed to approximate the PWR's primary and secondary cycles. Nine technicians receive the samples, three from each operating unit, and perform the required analyses. Acceptance criteria for successful performance on the blind parameters is based on the values found in the Institute of Nuclear Power Operations (INPO) Document 83-016, Revision 2, August 1989, Chemistry Quality Control Program. The goal of the program is to have each technician demonstrate acceptable performance on each of 16 analytical parameters. On completion of each monthly set, a summary report of all of the analytical results for the sample set is prepared. From the summary report, analytical bias can be detected, technician performance is documented, and overall laboratory performance can be evaluated. The program has been very successful at satisfying the INPO requirement that the analytical performance of each individual technician should be checked on at least a six-month frequency for all important parameters measured. This paper describes the program as implemented at the Palo Verde Nuclear Generating Station and provides a summary report and trend and bias graphs for illustrative purposes

  15. Core Follow Calculation for Palo Verde Unit 1 in Cycles 1 through 4 using DeCART2D/MASTER4.0 Code System

    International Nuclear Information System (INIS)

    Jeong, Hee Jeong; Choi, Yonghee; Kim, Sungmin; Lee, Kyunghoon

    2017-01-01

    To verify and validate the DeCART2D/MASTER4.0 design system, core follow calculations of Palo Verde Unit 1(PV-1) in cycles 1 through 4 are performed. The calculation results are compared with the measured data and will be used in the generation of bias and uncertainty factors in the DeCART2D/MASTER4.0 design system. The DeCART2D/MASTER codes system has been developed in KAERI for the PWR (Pressurized water reactors) core design including SMRs (Small Modular Reactors). Core follow calculations of Pale Verde Unit 1 in Cycles 1 through 4 have been performed. Reactivities, assembly powers and startup parameters such as EPC, RW, ITC and IBW are compared with the measured data. This work will be used in the generation of bias and uncertainty factors in DeCART2D/MASTER4.0 design system.

  16. Ouro Verde MG 2: nova cultivar de mungo-verde para Minas Gerais Ouro Verde MG 2: new mungbean cultivar for Minas Gerais State, Brazil

    Directory of Open Access Journals (Sweden)

    Rogério F. Vieira

    2002-03-01

    Full Text Available Dentre várias linhagens introduzidas do "Asian Vegetable Research and Development Center" (AVRDC, sobressaiu a linhagem VC 3984-B-2-B-4-1-B, que recebeu o nome de Ouro Verde MG 2. Suas sementes são verde-brilhantes e o peso de 1000 unidades varia de 43 a 51 g. O início da floração ocorre em torno de 33 dias após a emergência e a primeira vagem madura surge entre 23 e 33 dias. Por se tratar de espécie de maturação desuniforme, podem ser necessárias duas a quatro colheitas. As plantas podem atingir 95 cm de altura. As vagens são marrom-escuras e concentram-se na parte superior da planta. É suscetível a duas doenças que geralmente aparecem no final do ciclo de vida do mungo-verde: míldio-pulverulento (Erysiphe polygoni e mancha-foliar-de-cercospora (Cercospora canescens. A 'Ouro Verde MG 2' é resistente ao acamamento, e o seu rendimento, em três ensaios instalados em dezembro, janeiro e fevereiro, variou de 1,5 a 2,0 t/ha. Esses rendimentos foram, em média, 12% superior ao da cultivar Ouro Verde.Among many accessions introduced from Asian Vegetable Research and Development Center (AVRDC, the VC 3984-B-2-B-4-1-B stood out and was named 'Ouro Verde MG 2'. The seeds are bright green and 1000-seed weight ranges from 43 to 51 g. Flowering starts approximately 33 days after emergence and the first pod ripens between 23 and 33 days later. As mungbean is a non-uniform maturation species, two to four harvests could be necessary. The plant can reach 95 cm high. The pods are dark brown and concentrated in the upper canopy. This cv. is susceptible to two diseases which generally appear late in the crop: powdery mildew (Erysiphe polygoni and cercospora leaf spot (Cercospora canescens. 'Ouro Verde MG 2' is resistant to lodging. The yield measured in three experiments carried out in December, January, and February, ranged from 1.5 to 2.0 t/ha. In average, these yields were 12% superior than the achieved by the cultivar 'Ouro Verde'.

  17. Auxiliary feedwater system risk-based inspection guide for the Palo Verde Nuclear Power Plant

    International Nuclear Information System (INIS)

    Bumgardner, J.D.; Moffitt, N.E.; Gore, B.F.; Vo, T.V.; Sloan, J.A.

    1993-02-01

    In a study sponsored by the US Nuclear Regulatory Commission (NRC), Pacific Northwest Laboratory has developed and applied a methodology for deriving plant-specific risk-based inspection guidance for the auxiliary feedwater (AFW) system at pressurized water reactors that have not undergone probabilistic risk assessment (PRA). This methodology uses existing PRA results and plant operating experience information. Existing PRA-based inspection guidance information recently developed for the NRC for various plants was used to identify generic component failure modes. This information was then combined with plant-specific and industry-wide component information and failure data to identify failure modes and failure mechanisms for the AFW system at the selected plants. Palo Verde was selected as one of a series of plants for study. The product of this effort is a prioritized listing of AFW failures which have occurred at the plant and at other PWRs. This listing is intended for use by NRC inspectors in the preparation of inspection plans addressing AFW risk-important components at the Palo Verde plants

  18. Characterization of water and lake sediments in Laguna de Bay

    International Nuclear Information System (INIS)

    San Diego, Cherry Ann; Francisco, Pattrice Armynne; Navoa, Joshua Antonio; Johnson, Bryan; Dave, Harshil; Cryer, Karl; Panemanglor, Rajeev; Rama, Mariecar; Sucgang, Raymond J.

    2011-01-01

    In this work we studied elemental distributions of trace elements, dissolved oxygen and microbiological allotment (total plate count, Coliform, and E. coli) in sediment and surface water from 3 sites in Laguna de Bay. The measured parameters were associated with the quality of the water and to anthropogenic and geogenic processes taking place in the lake. In all cases sediment samples were collected and analyzed for elemental composition using an X-ray fluorescence technique. Water samples were collected and analyzed for nitrate, chloride, and sulfate ions using selective electrodes. Bicarbonate ions in the lake water were determined by titration. The microbial load (total plate count, total coliform and E,. Coli) were determined using Simplate. Field parameters such as pH and conductivity were likewise measured. Preliminary assumptions suggest that proximity to anthropogenic sources has substantially contributed to the combined loads of major ions pollution in the lake. Laguna de Bay is classified as Class C (DENR Administrative Order No. 34). For all the sites, the conductivity of the water were considerably elevated, which ranged from 929 to 933 uS/cm; Site 1 water exceeded the permissible range for pH for Class C water which is 6.5 to 8.5 for the support and rearing of fish. None of the lake waters exceeded the limits for the ions, chloride (set at 350 mg/L) and nitrate (set at 10 mg/L), for Class C water criteria. All the sites meet the dissolved oxygen, DO, criterion for Class C waters which is set at 5 mg/L. In terms of microbiological load, Site 1 had the least most probable number per ml of water, MPN/ml: total plate count (6720), Coliform (less that detection limit) and E. coli (less than LLD); Site 3 was the most contaminated: total plate count (greater than 70,000), Coliform(48768) and E. Coli (23808). X-ray fluorescence analyses of sediments allowed the determination of elements Na, Mg, Al, P, Si, Cl, K. Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, As, Br, Rb

  19. NPDES Permit for Mesa Verde National Park Wastewater Treatment Facility in Colorado

    Science.gov (United States)

    Under NPDES permit number CO-0034398, the United States Department of the Interior, National Park Service, Mesa Verde National Park is authorized to discharge from the Mesa Verde National Park wastewater treatment plant, in Montezuma County, Colo.

  20. Simulation of a scenario of total loss of external and internal power (Sbo) for different vent pressures of the containment of a BWR-5; Simulacion de un escenario de perdida total de potencia externa e interna (SBO) para distintas presiones de venteo de la contencion de un reactor BWR-5

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas V, J.; Mugica R, C. A.; Godinez S, V., E-mail: Jaime.cardenas@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan No. 779, Col. Narvarte, 03020 Mexico D. F. (Mexico)

    2014-10-15

    The simulation of a Station Black Out (Sbo) was realized with intervention of the vent containment by means of a rigid vent coming from the dry-well and that discharges directly to the atmosphere, with the MELCOR code version 2.1. This scenario was carried out for a BWR-5 and containment type Mark II, with a thermal power of 2317 MWt similar to the reactor of nuclear power plant of Laguna Verde. For this scenario was considered as only available system for coolant injection to the reactor to the Reactor Core Isolation Cooling (Rcic), which remained operating 4 hours with batteries bank. The Security and Relief Valves (SR V) were considered functional (by simplicity) and that they mechanically do not exceed their capacity to liberate pressure due to the performances in their safety way. The operator maneuver to perform the SR V and to de pressurize the vessel until the pressure (13 kg/cm{sup 2}) to operate the low pressure systems was modeled. The results cover approximately 48 hours (172000 seconds), time in which was observed the behavior of the level and pressure in the vessel. Also the scenario evolution was analyzed to different vent pressures of the primary containment (2.0, 3.0, 4.5, 6.0, and 10.0 kg/cm{sup 2}), the temperature profiles of the dry-well, the hydrogen accumulation in the containment, the radio-nuclides liberation through rigid vent to the atmosphere and the inventory of these. In this work an analysis of the pressure behavior in the primary containment is presented, with the purpose of minimizing liberated fission products to the environment. (Author)

  1. Neutron flux calculation and fluence in the encircling of the core and vessel of a reactor BWR

    International Nuclear Information System (INIS)

    Martinez C, E.

    2011-01-01

    One of the main objectives related to the safety of any nuclear power plant, including the nuclear power plant of Laguna Verde is to ensure the structural integrity of reactor pressure vessel. To identify and quantify the damage caused by neutron irradiation in the vessel of any nuclear reactor, it is necessary to know both the neutron flux and the neutron fluence that the vessel has been receiving during its operation lifetime, and that the damage observed by mechanical testing are products of microstructural effects induced by neutron irradiation; therefore, it is important the study and prediction of the neutron flux in order to have a better understanding of the damage that these materials are receiving. The calculation here described uses the DORT code, which solves the neutron transport equation in discrete ordinates in two dimensions (x-y, r-θ and r-z), according to a regulatory guide, it should make an approximation of the neutron flux in three dimensions by the so called synthesis method. It is called in that way because it achieves a representation of 3 Dimensional neutron flux combining or summarizing the fluxes calculated by DORT r-θ, r-z and r. This work presents the application of synthesis method, according to Regulatory Guide 1190, to determine the 3 Dimensional fluxes in internal BWR reactor using three different spatial meshes. The results of the neutron flux and fluence, using three different meshes in the directions r, θ and z were compared with results reported in the literature obtaining a difference not larger than 9.61%, neutron flux reached its maximum, 1.58 E + 12 n/cm 2 s, at a height H 4 (239.07 cm) and angle 32.236 o in the core shroud and 4.00 E + 09 n/cm 2 s at a height H 4 and angle 35.27 o in the inner wall of the reactor vessel, positions that are consistent to within ±10% over the ones reported in the literature. (Author)

  2. El anillo verde de Vitoria-Gasteiz

    Directory of Open Access Journals (Sweden)

    Marañón, Blanca

    2001-10-01

    de la periferia de la ciudad, donde coexistían zonas de alto valor ecológico sometidas a agresiones de todo tipo, con otros espacios degradados y marginales, fruto de la expansión urbana e industrial. La restauración ecológico-paisajística de estos espacios y su acondicionamiento para el uso público han permitido configurar un "anillo verde multifunción" en torno a la ciudad que está proporcionando importantes beneficios ambientales, sociales y económicos. El anillo verde ha jugado un papel importante en la integración naturaleza-ciudad, equilibrando la oferta de zonas verdes entre todos los barrios y favoreciendo la conexión entre los espacios verdes urbanos y los espacios naturales del entorno agrícola. Ha propiciado, asimismo, el desarrollo de nuevas actividades relacionadas con el ocio y el esparcimiento y con la formación, educación y sensibilización ambiental; actividades que, por un lado, están suponiendo un revulsivo para el sector empresarial ambiental y la integración socio-laboral de determinados colectivos sociales y, por otro, contribuyen a la conservación de estos espacios, al convertirse los usuarios en sus mayores defensores y guardianes. La utilización de algunos de estos espacios como superficies de laminación de agua en épocas de avenidas para solventar problemas de inundación en las zonas industriales es otro ejemplo del valor añadido obtenido al plantear soluciones integrales. Los excelentes resultados obtenidos tras nueve años de trabajo demuestran la viabilidad técnica y económica y la rentabilidad social de este proyecto, que representa una prueba evidente de la decidida voluntad municipal de avanzar hacia un modelo de ciudad sostenible en armonía con el medio natural que la rodea.

  3. Algorithms bio-inspired for the pattern obtention of control bars in BWR reactors; Algoritmos bio-inspirados para la obtencion de patrones de barras de control en reactores BWR

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz, J.J.; Perusquia, R.; Montes, J.L. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    In this work methods based on Genetic Algorithms and Systems based on ant colonies for the obtention of the patterns of control bars of an equilibrium cycle of 18 months for the Laguna Verde nuclear power station are presented. A comparison of obtained results with the methods and with those of design of such equilibrium cycle is presented. As consequence of the study, it was found that the algorithm based on the ant colonies reached to diminish the coast down period (decrease of power at the end of the cycle) in five and half days with respect to the original design what represents an annual saving of $US 100,000. (Author)

  4. 75 FR 52045 - Arizona Public Service Company, Palo Verde Nuclear Generating Station, Unit 3; Environmental...

    Science.gov (United States)

    2010-08-24

    ... Company, Palo Verde Nuclear Generating Station, Unit 3; Environmental Assessment and Finding of No.... NPF-74, issued to Arizona Public Service Company (APS, the licensee), for operation of Palo Verde... Statement for the Palo Verde Nuclear Generating Station, NUREG-0841, dated February 1982. Agencies and...

  5. 75 FR 47808 - Verde Hydro, LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting...

    Science.gov (United States)

    2010-08-09

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 13819-000] Verde Hydro, LLC... Intervene, and Competing Applications August 2, 2010. On July 21, 2010, Verde Hydro, LLC filed an... the feasibility of the Verde Hydroelectric Project, located in Maricopa County, in the State of...

  6. 77 FR 9974 - Notice of Entering Into a Compact With the Republic of Cape Verde

    Science.gov (United States)

    2012-02-21

    ... Republic of Cape Verde AGENCY: Millennium Challenge Corporation. ACTION: Notice. SUMMARY: In accordance..., and the Republic of Cape Verde. Representatives of the United States Government and the Republic of Cape Verde executed the Compact documents on February 10, 2012. Dated: February 14, 2012. Melvin F...

  7. Total mercury of selected fish species from Laguna de Bay

    International Nuclear Information System (INIS)

    Relon, Milagros Lontoc

    1996-01-01

    Dalag Ophicephalus striatus Block, kanduli Arius thalassinus Ruppell, bia Amblygobius phalaena Cuvier et Valenciennes and tilapia Tilapia nilotica Linnnaeus collected from Laguna de Bay between Taguig and Binangonan area in August 1989 to July 1990 were analyzed for total mercury by atomic absorption spectrometry. The highest metal concentration in soft muscle tissue was observed in Dalag followed by kanduli, less in bia and least in tilapia with mean values of 0.021, 0.020, 0.013, and 0.008 ug/g, respectively. Analysis using two-way ANOVA showed a significant difference in the mean total mercury in ug/g in the difference fish samples, among the different months and the interaction between these two variables. Mean total mercury of the four fish samples were significantly higher in April than in October. The results show that the levels of total mercury in the fish samples are below the World Health Organization maximum tolerable consumption of mercury in food of 300 ug or 0.03 mg of total mercury per week. (author)

  8. Safety evaluation of liquid radioactive effluents treatment system in a BWR reactor, through the LIQM03 code

    International Nuclear Information System (INIS)

    Zorrilla R, S.H.

    1978-01-01

    In this work we made a safety evaluation of the liquid radioactive effluents system in a plant using a BWR similar to that now installed in Laguna Verde. For that purpose, the computation program ORIGENwas modified, in order to keep up to date and adapt it to the PDP 10 computer, which is operating at the Computation Department of the Nuclear Center of Mexico, the code LIQM03 was the result of this modification. As usual in this work we dealt with problems which were solved opportunely, now we have at our disposal the code LIQM03 which will be in the future a very useful tool for this kind of evaluations. (author)

  9. Estudio Limnológico preliminar de la Laguna Hule, Costa Rica

    Directory of Open Access Journals (Sweden)

    Elizabeth Ramírez R.

    2016-03-01

    Full Text Available La Laguna Hule, localizada en la Vertiente Caribe, Costa Rica a 750m sobre el nivel del mar, forma parte del complejo de lagunas volcánicas llamado “Bosque Alegre”. El área de la laguna es de 60.3 ha y su profundidad máxima de 22.5m. La investigación se realizó de abril a setiembre de 1989 determinándose, en cada muestreo la temperatura, el óxido disuelto, el ácido sulfhídrico (H2S, el pH, la alcalinidad y la concentración de iones calcio, magnesio, hierro y manganeso. La laguna presenta un perfil clinógrado de oxígeno; el 60% del volumen total es anóxico con presencia de H2S a partir de los 8m de profundidad. Los valores de pH y alcalinidad indican que las aguas son bicarbonatadas, caracterizándose por un alto contenido de hierro. La curva de temperatura señala una diferencia de hasta 4.3 °C entre la superifcie y el fondo, permitiendo a la laguna permanecer estratificada (hay un epilimnion y un hipolimnion bien definido.

  10. Metodología para la selección del régimen de flujo en lagunas de estabilización

    Directory of Open Access Journals (Sweden)

    Luis Eduardo Cruz T.

    2000-07-01

    Full Text Available Para modelar procesos biológicos, se necesita información sobre la estequiometría y cinética de las reacciones y sobre el régimen hidráulico del sistema. La estequiometría de una reacción se refiere a la cantidad de reactantes consumidos (tales como sustratos, y a la cantidad de productos formados (tales como microorganismos. El régimen hidráulico hace referencia a la configuración del flujo dentro y fuera del proceso y a la mezcla y distribución de los sólidos del fluido dentro del reactor. El presente artículo se centrará en estudiar los diferentes regímenes de mezcla y sus modelos cinéticos de degradación de materia orgánica aplicados al caso específico de la laguna de estabilización de aguas residuales del municipio de Tocancipá. Además se discute la metodología para determinar el tipo de flujo que sepresenta en una laguna de estabilización.

  11. Clima, cultura y disponibilidad de espacios verdes urbanos

    OpenAIRE

    Sierra, Eduardo Mario; Pérez, Silvia Patricia; Nizzero, Gustavo Raúl

    2002-01-01

    p.165-171 El rápido crecimiento urbano mundial hace que la calidad de vida dependa cada vez más de la disponibilidad de espacios verdes. Este trabajo trata de relacionar la disponibilidad de espacios verdes urbanos públicos con los factores climáticos y culturales. Las ciudades del Hemisferio Norte en países de cultura europea, donde se llevan a cabo programas de sustentabilidad muestran mayores disponibilidades lo cual refleja el impacto de los factores culturales. Desde el punto de vista...

  12. Strategic Analysis for the MER Cape Verde Approach

    Science.gov (United States)

    Gaines, Daniel; Belluta, Paolo; Herman, Jennifer; Hwang, Pauline; Mukai, Ryan; Porter, Dan; Jones, Byron; Wood, Eric; Grotzinger, John; Edgar, Lauren; hide

    2009-01-01

    The Mars Exploration Rover Opportunity has recently completed a two year campaign studying Victoria Crater. The campaign culminated in a close approach of Cape Verde in order to acquire high resolution imagery of the exposed stratigraphy in the cliff face. The close approach to Cape Verde provided significant challenges for every subsystem of the rover as the rover needed to traverse difficult, uncharacterised terrain and approach a cliff face with the potential of blocking out solar energy and communications with Earth. In this paper we describe the strategic analyses performed by the science and engineering teams so that we could successfully achieve the science objectives while keeping the rover safe.

  13. Aves acuáticas de la laguna de Acuitlapilco, Tlaxcala, México

    Directory of Open Access Journals (Sweden)

    Juanita Fonseca

    2012-07-01

    Full Text Available Estudiamos la abundancia y distribución estacional de las aves acuáticas en la laguna de Acuitlapilco, Tlaxcala, México. De febrero de 2011 a enero de 2012, realizamos censos en puntos de conteo para el registro de las especies. Registramos un total de 36 especies de aves acuáticas con una abundancia total acumulada de 48,794 individuos. Doce de las especies registradas fueron residentes, 10 migratorias y 14 fueron especies transitorias o de registro accidental. Observamos que la mayor riqueza de especies y abundancia de aves fueron en invierno, cuando la mayoría de las especies migratorias llegaron a la laguna. Nuestros resultados muestran que esta área es importante para especies de aves acuáticas tanto residentes como migratorias, y refleja la necesidad de un mayor número de estudios sobre el papel de las lagunas continentales como reservorios de biodiversidad.

  14. Investigation of chikungunya fever outbreak in Laguna, Philippines, 2012

    Directory of Open Access Journals (Sweden)

    Julius Erving Ballera

    2015-12-01

    Full Text Available Background: In July 2012, the Philippines National Epidemiology Center received a report of a suspected chikungunya fever outbreak in San Pablo City, Laguna Province, the first chikungunya cases reported from the city since surveillance started in 2007. We conducted an outbreak investigation to identify risk factors associated with chikungunya. Methods: A case was defined as any resident of Concepcion Village in San Pablo City who had fever of at least two days duration and either joint pains or rash between 23 June and 6 August 2012. Cases were ascertained by conducting house-to-house canvassing and medical records review. An unmatched case-control study was conducted and analysed using a multivariate logistic regression. An environmental investigation was conducted by observing water and sanitation practices, and 100 households were surveyed to determine House and Breteau Indices. Human serum samples were collected for confirmation for chikungunya IgM through enzyme-linked immunosorbent assay. Results: There were 98 cases identified. Multivariate analysis revealed that having a chikungunya case in the household (adjusted odds ratio [aOR]: 6.2; 95% confidence interval [CI]: 3.0–12.9 and disposing of garbage haphazardly (aOR: 2.7; 95% CI: 1.4–5.4 were associated with illness. House and Breteau Indices were 27% and 28%, respectively. Fifty-eight of 84 (69% serum samples were positive for chikungunya IgM. Conclusion: It was not surprising that having a chikungunya case in a household was associated with illness in this outbreak. However, haphazard garbage disposal is not an established risk factor for the disease, although this could be linked to increased breeding sites for mosquitoes.

  15. Desarrollo, trabajo y género: El caso de la Laguna de Yahuarcocha

    Directory of Open Access Journals (Sweden)

    Diosey Ramon Lugo-Morin

    2015-06-01

    Full Text Available El presente estudio propone valorar el papel de la mujer rural de los territorios aledaños a la Laguna de Yahuarcocha.  Escenario propicio para generar una dinámica económica en las comunidades de San Miguel de Yahuarcocha y Priorato donde las mujeres tienen un rol de importancia estratégica.  Se concluye que la participación de  las mujeres en la dinámica económica entorno a la Laguna de Yahuarcocha es determinante para el desarrollo del territorio sobre todo en el ámbito turístico.

  16. Fuel design with low peak of local power for BWR reactors with increased nominal power

    International Nuclear Information System (INIS)

    Perusquia C, R.; Montes, J.L.; Hernandez, J.L.; Ortiz, J.J.; Castillo, A.

    2006-01-01

    The Federal Commission of Electricity recently announcement the beginning of the works related with the increase of the power to 120% of the original nominal one in the Boiling Water Reactors (BWR) of the Laguna Verde Central (CLV): In the National Institute of Nuclear Research (ININ) are carried out studies of the impact on the design of the recharge of derived fuel of this increase. One of the main effects of the power increase type that it is promoting, is the increment of the flow of generated vapor, what takes, to a bigger fraction of vacuum in the core presenting increased values of the maximum fraction to the limit, so much of the ratio of lineal heat generation (XFLPD) as of the ratio of critic power (MFLCPR). In the made studies, it is found that these fractions rise lineally with the increase of the nominal power. Considering that the reactors of the CLV at the moment operate to 105% of the original nominal power, it would imply an increment of the order of 13.35% in the XFLPD and in the MFLCPR operating to a nominal power of 120% of the original one. This would propitiate bigger problems to design appropriately the fuel cycle and the necessity, almost unavoidable, of to resort to a fuel assembly type more advanced for the recharges of the cores. As option, in the ININ the feasibility of continuing using the same type of it fuel assembles that one has come using recently in the CLV, the type GE12 is analyzed. To achieve it was outlined to diminish the peak factor of local power (LPPF) of the power cells that compose the fuel recharge in 13.35%. It was started of a fuel design previously used in the recharge of the unit 1 cycle 12 and it was re-design to use it in the recharge design of the cycle 13 of the unit 1, considering an increase to 120% of the original power and the same requirements of cycle extension. For the re-design of the fuel assembly cell it was used the PreDiCeldas computer program developed in the ININ. It was able to diminish the LPPF

  17. Verde Valley Community Needs Assessment Project, Spring 1979.

    Science.gov (United States)

    Gose, Frank J.

    A study of the educational needs to be met by the Verde Campus of Yavapai College (YC) involved surveying seven populations. Responses were returned by 88 non-retired community residents, 96 retired members of the community, 191 members of the business sector, 240 current students, 208 former students, 19 faculty members, and 261 high school…

  18. Prefabricated solution to modular construction in Cape Verde

    Science.gov (United States)

    Vieira, Nuno; Amado, Miguel; Pinho, Fernando

    2017-02-01

    Nowadays, the lack of adequate housing in Cape Verde is a growing problem. The migration of the population living in the countryside to the major cities generates an increase of the diameter of the cities. With the lack of economic power, the migrating families tend to occupy the land with houses which don't present proper conditions to living. Praia is the capital of Cape Verde and so on the biggest city of the country. This fact leads Praia to being the city with major economic power and job offer in all country. Consequently, Praia has developed the biggest slum of the Cape Verde and it is urgent to approach this problem in order to create solutions that reveal capacity to start solving it. Cape Verde's unique dry subtropical climate turns indispensable a careful resolution of the housing, in order to ensure the comfort of the occupants. The modular construction is a solution with potential to approach this problem with a fast and economic response. In order to answer the situation, this article introduces a modular solution in order to reach the needing of thermal comfort to the specific case of Praia.

  19. Paso del Aguilo : Jarre de type Rio Verde Poli

    OpenAIRE

    Michelet , Dominique

    1981-01-01

    Zone IV, site n°2. Las Colaciones, Paso del Aguila, municipio Armadillo, San Luis Potosi.Jarre à deux petites anses latérales sous le col, du type Rio Verde Poli. Engobe brun-beige poli. Hauteur totale 13 centimètres. Collection particulière Paso del Aguila.

  20. Design Study for a Future Laguna-LBNO Long-Baseline Neutrino Facility at CERN

    CERN Document Server

    Alabau-Gonzalvo, J; Antoniou, F; Benedikt, M; Calviani, M; Efthymiopoulos, I; Ferrari, A; Garoby, R; Gerigk, F; Gilardoni, S; Goddard, B; Kosmicki, A; Lazaridis, C; Osborne, J; Papaphillippou, Y; Parfenova, A; Shaposhnikova, E; Steerenberg, R; Velten, P; Vincke, H

    2013-01-01

    The Large Apparatus studying Grand Unification and Neutrino Astrophysics (LAGUNA) study [1] investigated seven pre-selected underground sites in Europe (Finland, France, Italy, Poland, Romania, Spain and UK), capable of housing large volume detectors for terrestrial, accelerator generated and astrophysical neutrino research. The study was focused on geo-technical assessment of the sites, concluding that no show-stoppers exist for the construction of the required large underground caverns in the chosen sites. The LAGUNA-LBNO FP7/EC-funded design study extends the LAGUNA study in two key aspects: the detailed engineering of detector construction and operation, and the study of a long-baseline neutrino beam from CERN, and possibly other accelerator centres in Europe. Based on the findings of the LAGUNA study, the Pyh¨asalmi mine in Finland is chosen as prime site for the far detector location. The mine offers the deepest underground location in Europe (-1400 m) and a baseline of 2’300 km from CERN (Fig. 1). ...

  1. A pollen diagram from “Laguna de la Herrera” (Sabana de Bogota)

    NARCIS (Netherlands)

    Hammen, van der T.; Gonzalez, E.

    1965-01-01

    The Laguna de La Herrera (alt. ca 2550 m) is a lake situated on the western border of the Sabana de Bogotá, near Mosquera (dept. of Cundinamarca, Colombia) (fig. 2). This part of the Sabana has a relatively dry climate (appr. 600—700 mm rainfall), as it lies in the rain-shadow of the hills that

  2. Reassessment of the 1892 Laguna Salada Earthquake: Fault Kinematics and Rupture Patterns

    Czech Academy of Sciences Publication Activity Database

    Rockwell, T.K.; Fletcher, J.M.; Teran, O.J.; Hernandez, A.P.; Mueller, K.J.; Salisbury, J.B.; Akciz, S.O.; Štěpančíková, Petra

    2015-01-01

    Roč. 105, č. 6 (2015), s. 2885-2893 ISSN 0037-1106 R&D Projects: GA MŠk LH12078 Institutional support: RVO:67985891 Keywords : paleoseismology * earthquake s * fault kinematics * Laguna Salada * Mexico Subject RIV: DB - Geology ; Mineralogy Impact factor: 2.311, year: 2015

  3. Cape Verde: Marketing Good Governance Kap Verde: Die Vermarktung von Good Governance

    Directory of Open Access Journals (Sweden)

    Bruce Baker

    2009-01-01

    Full Text Available Faced with a lack of natural resources Cape Verde has made good governance one of its most marketable products. Running parallel to the institutionalisation of democratic politics there has been an overhaul and growing sophistication in public administration, though certain weaknesses persist. This report argues that it is reform and improvement in this area in particular that has enabled this small island state to punch above its weight and achieve remarkable social, economic and political results. But will the successful formula of the past decade prove sufficient for the future? Poverty and unemployment have by no means been conquered. Much of the economic growth has been based in the tourist sector and the government is well aware of the dangers of over-reliance on a single industry. Cape Verde’s midway location between South America and Europe and its increasing international transport connections will continue to offer advantages to drug traffickers. The next few years of the world financial crisis will show whether marketing good governance is enough and whether this is the model for small resource developing states. Der Inselstaat Kap Verde hat seine Anstrengungen zu guter Regierungsführung (Good Governance erfolgreich demonstriert. Parallel zur Institutionalisierung demokratischer Regierungsstrukturen wurde die Verwaltung reformiert und modernisiert, wenn auch immer noch Problembereiche erkennbar sind. Der Autor sieht insbesondere in den politischen und administrativen Reformen den Hintergrund für die erfolgreiche soziale, wirtschaftliche und politische Entwicklung dieser kleinen Inselrepublik. Aber wird dieses Rezept, das im vergangenen Jahrzehnt seine Wirksamkeit beweisen konnte, auch in Zukunft ausreichend sein? Armut und Unterbeschäftigung sind keineswegs besiegt. Ein Großteil des Wirtschaftswachstums basiert auf dem Tourismussektor; die Regierung ist sich der Gefahr wohl bewusst, die in zu großer Abhängigkeit von einem

  4. Inspection activities of the Mexican regulatory body during the construction stage of the first unit of Laguna Verde Nuclear Power Plant

    International Nuclear Information System (INIS)

    Salgado Gonzalez, Julio Ricardo

    1996-01-01

    The paper addresses the regulatory framework established for the design, construction and operation of the NPP. The regulatory bases of the inspection program are mentioned.A summary of the inspection and reviewing activities carried out by the former Nuclear Safety Management Construction area during the construction stage, taking the year 1977 as the beginning of regular inspection activities for this construction stage, and up to the year 1987, when this one is considered as practically completed, and a stage of pre-operational tests has been started. Finally, the main inspection areas are described, and a summary is given of the classification of deficiencies detected during the inspections

  5. Fuel design with low peak of local power for BWR reactors with increased nominal power; Diseno de un combustible con bajo pico de potencia local para reactores BWR con potencia nominal aumentada

    Energy Technology Data Exchange (ETDEWEB)

    Perusquia C, R.; Montes, J.L.; Hernandez, J.L.; Ortiz, J.J.; Castillo, A. [ININ, 52750 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: mrpc@nuclear.inin.mx

    2006-07-01

    The Federal Commission of Electricity recently announcement the beginning of the works related with the increase of the power to 120% of the original nominal one in the Boiling Water Reactors (BWR) of the Laguna Verde Central (CLV): In the National Institute of Nuclear Research (ININ) are carried out studies of the impact on the design of the recharge of derived fuel of this increase. One of the main effects of the power increase type that it is promoting, is the increment of the flow of generated vapor, what takes, to a bigger fraction of vacuum in the core presenting increased values of the maximum fraction to the limit, so much of the ratio of lineal heat generation (XFLPD) as of the ratio of critic power (MFLCPR). In the made studies, it is found that these fractions rise lineally with the increase of the nominal power. Considering that the reactors of the CLV at the moment operate to 105% of the original nominal power, it would imply an increment of the order of 13.35% in the XFLPD and in the MFLCPR operating to a nominal power of 120% of the original one. This would propitiate bigger problems to design appropriately the fuel cycle and the necessity, almost unavoidable, of to resort to a fuel assembly type more advanced for the recharges of the cores. As option, in the ININ the feasibility of continuing using the same type of it fuel assembles that one has come using recently in the CLV, the type GE12 is analyzed. To achieve it was outlined to diminish the peak factor of local power (LPPF) of the power cells that compose the fuel recharge in 13.35%. It was started of a fuel design previously used in the recharge of the unit 1 cycle 12 and it was re-design to use it in the recharge design of the cycle 13 of the unit 1, considering an increase to 120% of the original power and the same requirements of cycle extension. For the re-design of the fuel assembly cell it was used the PreDiCeldas computer program developed in the ININ. It was able to diminish the LPPF

  6. Talento verde: caracterización y búsqueda

    Directory of Open Access Journals (Sweden)

    María del Carmen Torres-Salazar

    2015-01-01

    Full Text Available Introducción: Los impactos del calentamiento global y el cambio climático son una preocupación en prácticamente todos los sectores de la sociedad, debido a las consecuencias que ya se perciben y que afectarán cada día más tanto a los sistemas naturales como a los creados por el hombre, generalmente de forma negativa. Para revertir estos efectos negativos y no continuar deteriorando el medio ambiente, es necesario un tipo especial de personas que sean capaces de tomar las decisiones adecuadas en los ámbitos en los que se desenvuelven. En esta investigación, estos seres humanos se denominan: “personas con talento verde”. El término talento verde no ha sido caracterizado y su uso es aun restringido. Esta investigación hace una caracterización del talento verde y propone una encuesta para detectar a las personas que cuentan con estas características. En este artículo, se reporta solo la validación de la encuesta. Es importante hacer notar que este trabajo forma parte de una investigación más amplia que busca conocer la relación entre directivos con talento verde y prácticas de cadena de suministro sustentable. Método: La caracterización del talento verde se realizó a través de la metodología de representaciones sociales, de la cual surgieron una serie de preguntas que buscan las características de talento verde en directivos de empresas y que forman parte de una encuesta de mayor cobertura que fue piloteada para su validación. La confiabilidad se midió a través del Alfa de Crombach y la validez por un Análisis Factorial. Resultados: Se encontraron nueve aspectos que caracterizan a las personas con talento verde, con las cuales se construyeron también nueve preguntas. Estas preguntas se hicieron a 25 directivos de empresas que participan en la Cámara de la Industria de la Transformación (CANACINTRA con el objetivo de validar el instrumento. El alfa de Crombrach obtenido fue del 0.948 y el análisis factorial indica

  7. Cabo Verde telemedicine program: initial results of nationwide implementation.

    Science.gov (United States)

    Latifi, Rifat; Dasho, Erion; Merrell, Ronald C; Lopes, Miguel; Azevedo, Vanda; Bekteshi, Flamur; Osmani, Kalterina L; Qesteri, Orland; Kucani, Julian; Lecaj, Ismet

    2014-11-01

    Telemedicine and e-health have been suggested as one solution for closing the health disparity gap between the developed world and the developing world. Yet evidence is lacking from current successful programs in the developing world and, in particular, from sub-Saharan Africa. The primary objective of our study was to present the preliminary results of our efforts in building the Integrated Telemedicine and e-Health Program for Cabo Verde (ITeHP-CV), with an emphasis on initial utilization and results. This is a prospective study of data collected while we worked to establish a fully functional, integrated national telemedicine network and virtual education network in Cabo Verde. We used the International Virtual e-Hospital Foundation strategic approach known as "initiate-build-operate-transfer" over a 26-month period (November 2011-December 2013). We describe herein the five main pillars of this process that have been implemented: (1) capacity building; (2) network development and deployment of equipment; (3) implementation of clinical telemedicine; (4) implementation of activities related to continuing medical education, delivered from within the country and from abroad; and (5) establishment and use of the electronic virtual library. Based on comprehensive technical and medical assessment of the country's needs, 10 fully functional telemedicine centers in all nine inhabited islands of the Republic of Cabo Verde have been established. RESULTS are presented under the five main pillars of capacity building, network deployment, implementation of clinical telemedicine, implementation of continuing medical education activities, and establishment of the electronic virtual library. The ITeHP-CV has been successfully launched, and the initial results are encouraging. The continuity of the program and sustainability are primary goals once the program is transferred fully to the Ministry of Health of Cabo Verde. A long-term follow-up study is required in order to ensure

  8. Community-based tourism in Cape Verde - a case study

    OpenAIRE

    Tomas Lopez-Guzman; Osvaldo Borges; Ana Maria Castillo-Canalejo

    2011-01-01

    Community-based tourism is taking its place in the world as an alternative to traditional tourist destinations, especially in developing countries. This form of tourism allows for greater contact with the local community and for the tourist to experience new sensations while enabling the economic and social development of the geographic area. In this paper, the results of fieldwork carried out in the island of Fogo (Cape Verde) are presented, assessing the opinion and perception tourists visi...

  9. Les enjeux écologiques de Palo Verde (Costa Rica

    Directory of Open Access Journals (Sweden)

    Bertrand LÉVY

    1992-09-01

    Full Text Available Près de Palo Verde a été créé un parc naturel. Un projet d’irrigation risque de perturber l’écologie de la région. Une carte de son écosystème a été établie par télédétection, pour évaluer l’impact d’un tel projet.

  10. Verde Macael: A Serpentinite Wrongly Referred to as a Marble

    Directory of Open Access Journals (Sweden)

    Santiago del Barrio

    2013-02-01

    Full Text Available Serpentinites are used in both exterior and interior locations, but not all serpentinites are equal: they vary in physical-mechanical behavior and are not all suitable for similar uses. The serpentinites most commonly used worldwide come from India, Pakistan or Egypt. Spain has traditionally quarried two ultramafic massifs, one in Galicia (Verde Pirineos and one in Andalucía (Verde Macael. Some of these quarries were small family-run businesses. In both cases, these rocks are commercially available as “green marble.” These serpentinites commonly have a high degree of carbonation, but the process does not always take place with the same intensity. Carbonate can act as a cementing agent of the other phases, increasing the mechanical strength parameters. As a result, an improvement in the strength conditions is achieved, but a misinterpretation of the suitability of the rock may occur because a perception among users that “green marble” is similar to geologically defined marble. This may lead to inappropriate applications as an ornamental stone. At a time of economic crisis in Europe, the natural stone sector is encouraged to invest in research to identify the best quality products that can compete profitably with those currently being imported from other countries. This paper provides a comparison of properties of the Verde Macael serpentinite with a true marble in the hope of contributing to improving the natural stone industrial sector.

  11. Renewable energy projects to electrify rural communities in Cape Verde

    International Nuclear Information System (INIS)

    Ranaboldo, Matteo; Lega, Bruno Domenech; Ferrenbach, David Vilar; Ferrer-Martí, Laia; Moreno, Rafael Pastor; García-Villoria, Alberto

    2014-01-01

    Highlights: • The design of 2 off-grid electrification projects in Cape Verde is developed. • Configurations with hybrid renewable energy systems and micro-grids are considered. • A detailed micro-scale wind resource assessment is carried out. • An optimization model is used in order to support the design. • The proposed system is economically beneficial in comparison with diesel generation. - Abstract: Even though Cape Verde has high wind and solar energy resources, the conventional strategy for increasing access to electricity in isolated rural areas is by centralized microgrids with diesel generators. In this study, the design of 2 off-grid electrification projects based on hybrid wind–photovoltaic systems in Cape Verde is developed and analyzed. The design considers some significant novelty features in comparison with previous studies. First a detailed wind resource assessment is carried out combining meso-scale wind climate data and a specialized micro-scale wind flow model. Then a mathematical model is used for the design of off-grid projects considering a combination of individual systems and microgrids. In this study, locations far from the demand points are also considered as possible generation points. Various design configurations are analyzed and compared. The proposed configurations exploit the highest wind potential areas and are economically beneficial in comparison with diesel generator systems

  12. Living With Parasites in Palo Verde National Park

    Directory of Open Access Journals (Sweden)

    Eben Kirksey

    2012-11-01

    Full Text Available Bruno Latour has tried to bring a parliamentary democracy to the domain of nature. Wading through the swamps of Palo Verde, a national park in the Guanacaste Province of Costa Rica, and wandering onto neighbouring agricultural lands, I failed to find a central place where people were speaking for nature. Departing from a failed attempt to speak for another species (the fringe-toed foam frog, this paper considers how diverging values and obligations shape relationships in multi-species worlds. As spokespersons articulated competing visions of nature on the borderlands of Palo Verde, multiple social and ecological worlds went to war. The haunting specter of capital joined the fray—animating the movements of cattle, grasses with animal rhizomes, rice seeds, and flighty ducks across national borders and through fragmented landscapes. Amidst this warfare, the fringe-toed foam frog was just one tenacious parasite, a noisy agent eating at the table of another, which began to flourish in worlds designed with the well-being of others in mind. Cattails, charismatic birds, and a multitude of insects began interrupting human dreams and schemes. Final solutions to the problem of living with parasites failed in Palo Verde. Humans and parasites, who became para-selves of one another, maintained an abiding presence in the landscape.

  13. 'ILRT' integrated leak reason test of the primary restraint of the reactor

    International Nuclear Information System (INIS)

    Herrera C, G.

    2006-01-01

    To obtain the operation licenses of the Units 1 and 2 of the Laguna Verde Nucleo electric plant, its were required to fulfill certain license points, inside which is the one of limiting capable and dependably the displacement of radioactive materials to the environment, later to a postulated event of lost of coolant ('LOCA' by its initials in english), accident basis of design, so that the doses outside of place, be smaller to the established ones in the chapter 10 of the Code of Federal Regulations of United States of America Part 100 (10CFR100), to be the supplying country of the reactor. The design of the container uses the characteristics of Dry Well and Pressure Suppression pool in the concept of Contention BWR-Mark II. In the event of being presented a 'LOCA', the flight to the exterior of the primary container will be limited to a global flight reason integrated smaller or similar to 0.5 percent in weight of the air of the contention for every 24 hours to an accident pressure, similar to 2.6 Kg/cm 2 (37.0 psig), as they indicate it the Technical Specifications of Operation of the CLV, based on the context of the Option B of the Appendix J on the 10CFR50. For this end, its will be known parameters such as: pressure, temperature and volume, making necessary then the use of additional sensors for monitoring these parameters and by means of the ideal gases equation, to calculate the punctual mass in that instant contained inside the primary contention. The pressure of the primary contention is taken to accident pressure by means of a compressors train. The information of the sensors is channeled to a computer system which will calculate, starting from a time zero and pressure of accident of 37 psig (tight), the punctual mass of the primary contention in a lapse of 24 hs, with that which through the one time and by means of mathematical calculations, we will know the mass percentage escaping through the same one, that which will fulfill that indicated in the

  14. Population size, breeding biology and on-land threats of Cape Verde petrel (Pterodroma feae) in Fogo Island, Cape Verde.

    Science.gov (United States)

    Militão, Teresa; Dinis, Herculano Andrade; Zango, Laura; Calabuig, Pascual; Stefan, Laura M; González-Solís, Jacob

    2017-01-01

    Cape Verde petrel (Pterodroma feae) is currently considered near threatened, but little is known about its population size, breeding biology and on land threats, jeopardizing its management and conservation. To improve this situation, we captured, marked and recaptured (CMR) birds using mist-nets over 10 years; measured and sexed them; monitored up to 14 burrows, deployed GPS devices on breeders and analyzed activity data of geolocators retrieved from breeders in Fogo (Cape Verde). We set cat traps over the colony and investigated their domestic/feral origin by marking domestic cats from a nearby village with transponders, by deploying GPS devices on domestic cats and by performing stable isotope analyses of fur of the trapped and domestic cats. The population of Fogo was estimated to be 293 birds, including immatures (95% CI: 233-254, CMR modelling). Based on geolocator activity data and nest monitoring we determined the breeding phenology of this species and we found biometric differences between sexes. While monitoring breeding performance, we verified a still ongoing cat predation and human harvesting. Overall, data gathered from trapped cats without transponder, cats GPS trips and the distinct isotopic values between domestic and trapped cats suggest cats visiting the colony are of feral origin. GPS tracks from breeders showed birds left and returned to the colony using the sector NE of the islands, where high level of public lights should be avoided specially during the fledging period. Main threats for the Cape Verde petrel in the remaining breeding islands are currently unknown but likely to be similar to Fogo, calling for an urgent assessment of population trends and the control of main threats in all Cape Verde Islands and uplisting its conservation status.

  15. Population size, breeding biology and on-land threats of Cape Verde petrel (Pterodroma feae in Fogo Island, Cape Verde.

    Directory of Open Access Journals (Sweden)

    Teresa Militão

    Full Text Available Cape Verde petrel (Pterodroma feae is currently considered near threatened, but little is known about its population size, breeding biology and on land threats, jeopardizing its management and conservation. To improve this situation, we captured, marked and recaptured (CMR birds using mist-nets over 10 years; measured and sexed them; monitored up to 14 burrows, deployed GPS devices on breeders and analyzed activity data of geolocators retrieved from breeders in Fogo (Cape Verde. We set cat traps over the colony and investigated their domestic/feral origin by marking domestic cats from a nearby village with transponders, by deploying GPS devices on domestic cats and by performing stable isotope analyses of fur of the trapped and domestic cats. The population of Fogo was estimated to be 293 birds, including immatures (95% CI: 233-254, CMR modelling. Based on geolocator activity data and nest monitoring we determined the breeding phenology of this species and we found biometric differences between sexes. While monitoring breeding performance, we verified a still ongoing cat predation and human harvesting. Overall, data gathered from trapped cats without transponder, cats GPS trips and the distinct isotopic values between domestic and trapped cats suggest cats visiting the colony are of feral origin. GPS tracks from breeders showed birds left and returned to the colony using the sector NE of the islands, where high level of public lights should be avoided specially during the fledging period. Main threats for the Cape Verde petrel in the remaining breeding islands are currently unknown but likely to be similar to Fogo, calling for an urgent assessment of population trends and the control of main threats in all Cape Verde Islands and uplisting its conservation status.

  16. Tres patos ocasionales en la Sabana de Bogotá y la Laguna de Fúquene

    Directory of Open Access Journals (Sweden)

    Borrero José Ignacio

    1944-12-01

    Full Text Available Agradezco al Dr. Armando Dugand la ayuda que se sirvió dispensarme para la presentación de este articulo. Creo de interes, para principiar, hacer una breve descripción de las condiciones de la Sabana de Bogotá y la Laguna de Fúquene, como localidades de paso o estacionamiento temporal para las especies migratorias de Anátidas.  La Sabana de Bogotá ocupa una vasta altiplanicie de unos 2000 kilómetros cuadrados a 2600 mts. de altura media, rodeada de montanas o cerros en toda su extensión y cruzada por pequeños rios. El rio Bogotá, que la atraviesa, forma en sus riberas y en casi toda su extensión grandes lagunas y pantanos apropiados para la llegada de los patos y otras aves acuáticas que anualmente vienen del Norte y otras regiones.

  17. Influence of a carp invasion on the zooplankton community in Laguna Medina, a Mediterranean shallow lake

    OpenAIRE

    Norbert, Florian; López-Luque, raquel; Ospina-Álvarez, Natalia; Hufnagel, Levente; Green, Andy J.

    2016-01-01

    The common carp (Cyprinus carpio) is a highly invasive species and an ecological engineer. It has been repeatedly shown to increase nutrient concentrations and phytoplankton biomass while destroying submerged macrophytes, although there are few studies from the Mediterranean region. We studied its impact on the zooplankton community in Laguna de Medina lake, a shallow lake in Jerez de la Frontera, south-west Spain. Carp were removed with rotenone in 2007 but returned in 2010-2011. ...

  18. Textural and geochemical features of freshwater microbialites from Laguna Bacalar, Quintana Roo, Mexico

    OpenAIRE

    Castro-Contreras, Set I.; Gingras, Murray K.; Pecoits, Ernesto; Aubet, Natalie R.; Petrash, Daniel; Castro-Contreras, Saulo M.; Dick, Gregory; Planavsky, Noah J.; Konhauser, Kurt O.

    2014-01-01

    Microbialites provide some of the oldest direct evidence of life on Earth. They reached their peak during the Proterozoic and declined afterward. Their decline has been attributed to grazing and/or burrowing by metazoans, to changes in ocean chemistry, or to competition with other calcifying organisms. The freshwater microbialites at Laguna Bacalar (Mexico) provide an opportunity to better understand microbialite growth in terms of interaction between grazing organisms versus calcium carb...

  19. TRATAMIENTO DE EFLUENTES PISCÍCOLAS (TILAPIA ROJA EN LAGUNAS CON Azolla pinnata

    Directory of Open Access Journals (Sweden)

    GUILLERMO CHAUX F

    2013-12-01

    Full Text Available Los sistemas con plantas acuáticas flotantes son una alternativa económicamente sostenible para el tratamiento de efluentes piscícolas. Se evaluó a escala piloto el desempeñ,o de un sistema de lagunas con Azolla pinnata en serie para el tratamiento de efluentes de cría de tilapia roja durante el proceso de levante y engorde. El sistema construido en la piscícola La Yunga (Popayán, Colombia consistió en dos líneas de cinco lagunas en serie; la primera con A. pinnata y la segunda sin la planta acuática; cada laguna se operó con un tiempo de detención de un día. La evaluación se realizó en época seca. La producción de Azolla fresca osciló entre 42 y 87 g/m2.d y el contenido de proteína entre 18,5% y 20,4%. Las eficiencias de remoción obtenidas en las líneas (con Azolla, sin Azolla fueron respectivamente: 56% y 46% DBO5; 49% y 26% DQO; 56% y 33% SST; 28% y 36% N-NTK; -108% y 23% N-NH4+; 64% y 34% fósforo total, mostrando superioridad del sistema con Azolla. Con solo tres lagunas en serie plantadas con A. pinnata se alcanzan las eficiencias máximas obtenidas en la remoción de DBO5, DQO, SST y fósforo total.

  20. Ceratopetalum (Cunoniaceae) fruits of Australasian affinity from the early Eocene Laguna del Hunco flora, Patagonia, Argentina.

    Science.gov (United States)

    Gandolfo, María A; Hermsen, Elizabeth J

    2017-03-01

    Radially symmetrical, five-winged fossil fruits from the highly diverse early Eocene Laguna del Hunco flora of Chubut Province, Patagonia, Argentina, are named, described and illustrated. The main goals are to assess the affinities of the fossils and to place them in an evolutionary, palaeoecological and biogeographic context. Specimens of fossil fruits were collected from the Tufolitas Laguna del Hunco. They were prepared, photographed and compared with similar extant and fossil fruits using published literature. Their structure was also evaluated by comparing them with that of modern Ceratopetalum (Cunoniaceae) fruits through examination of herbarium specimens. The Laguna del Hunco fossil fruits share the diagnostic features that characterize modern and fossil Ceratopetalum (symmetry, number of fruit wings, presence of a conspicuous floral nectary and overall venation pattern). The pattern of the minor wing (sepal) veins observed in the Patagonian fossil fruits is different from that of modern and previously described fossil Ceratopetalum fruits; therefore, a new fossil species is recognized. An apomorphy (absence of petals) suggests that the fossils belong within crown-group Ceratopetalum . The Patagonian fossil fruits are the oldest known record for Ceratopetalum . Because the affinities, provenance and age of the fossils are so well established, this new Ceratopetalum fossil species is an excellent candidate for use as a calibration point in divergence dating studies of the family Cunoniaceae. It represents the only record of Ceratopetalum outside Australasia, and further corroborates the biogeographic connection between the Laguna del Hunco flora and ancient and modern floras of the Australasian region. © The Author 2017. Published by Oxford University Press on behalf of the Annals of Botany Company.

  1. Correlation and Fishers’ Perception in Selected Sites in Laguna de Bay, Luzon Island, Philippines

    Directory of Open Access Journals (Sweden)

    Arthur J. Lagbas

    2017-01-01

    Full Text Available White goby (Glossogobius giuris Hamilton 1822 is an omnivorous, native fish species which can be found in Laguna de Bay and its tributaries, and in other bodies of water in the Philippines. Deteriorating water quality, unsustainable fishing practices, aquaculture and predation by introduced invasive species are threatening the population of white goby and other native fish species in Laguna de Bay. This study was conducted to correlate select physico-chemical parameters of lake water and zooplankton abundance, and to assess white goby population based on fishers’ perception. Water samples were collected in three sites in June, September and December 2014. Twenty one zooplankton species belonging to 12 families were identified. The most abundant and frequently encountered zooplankton species is Eurytemora affinis Poppe 1880. Zooplanktons were most abundant in June and lowest in September. Key informant interviews with local fishers revealed that white goby population was abundant in April to August while catch report showed that fish catch is abundant in June and least during December. The fish abundance in April to June could be attributed to high productivity especially in summer season. The fishers perceived that the population of white goby was declining mainly due to water pollution, aquaculture, and predation by invasive alien species. A multi-stakeholder sustainable watershed management should be adapted to improve the water quality and extinction of native fish species in Laguna de Bay.

  2. Radiocarbon dating of the Peruvian Chachapoya/Inca site at the Laguna de los Condores

    International Nuclear Information System (INIS)

    Wild, E.M.; Kutschera, W.; Seidler, H.; Steier, P.; Guillen, S.

    2005-01-01

    Full text: An archaeological site with several funerary houses built in the cliffs of the Laguna de los Condores by the Chachapoya people was discovered in 1997 in the cloud forest at a sea level of 2500 m in the Amazonas/San Martin area in Peru. The Chachapoya people and their culture is not fully understood until now and some myths entwine around the origin of that South American ancient civilisation. The Chachapoya are described as people of warriors, which were finally subdued by the Incas. A typical characteristic of their culture is the special burial of their dead in funeral bundles containing the remains of the bodies. At the Laguna de los Condores more that 200 mummies have been found and transferred to Leymebamba. During the rescue work of the mummies, which were in danger to be destroyed by looters, it turned out that two different burial patterns could be detected. It is assumed, that after conquering of the Chachapoyas, the Inca people took over also the burial cliff houses and used it for their own burials. The Incas themselves were subdued by the Spanish Conquistadors in 1532 AD. In order to shed light on the transition from the Chachapoya to the Inka dominance, which is connected with the history of the Laguna de los Condores funeral site, a multidisciplinary project between archaeologists, anthropologists and physicists has been started. VERA contributes to this project with several radiocarbon dates of archaeological objects and of the mummies from this Chachapoya/Inca site. (author)

  3. 77 FR 14058 - Santa Teresa Southern Railroad, LLC-Operation Exemption-Rail Line of Verde Logistics Railroad...

    Science.gov (United States)

    2012-03-08

    ... Southern Railroad, LLC--Operation Exemption--Rail Line of Verde Logistics Railroad, LLC at Santa Teresa... notice of exemption under 49 CFR 1150.31 to operate approximately 12,000 feet of rail line owned by Verde Logistics Railroad, LLC (Verde). The rail line extends between a point of connection with Union Pacific...

  4. 76 FR 24064 - Arizona Public Service Company, Palo Verde Nuclear Generating Station, Units 1, 2, and 3, Notice...

    Science.gov (United States)

    2011-04-29

    ... Service Company, Palo Verde Nuclear Generating Station, Units 1, 2, and 3, Notice of Issuance of Renewed... Company (licensee), the operator of the Palo Verde Nuclear Generating Station, Units 1, 2, and 3 (PVNGS... Plants: Supplement 43, Regarding Palo Verde Nuclear Generating Station,'' issued January 2011, discusses...

  5. Atmospheric emissions control at ENELVEN`s Ramon Laguna thermal power plant; Control de emisiones a la atmosfera en la central termoelectrica Ramon Laguna de ENELVEN

    Energy Technology Data Exchange (ETDEWEB)

    Rincon Rincon, Edis Rafael [Empresa de Servicio Electrico (ENELVEN), (Venezuela)

    1996-12-31

    ENELVEN is an electric utility that covers the areas of generation, transmission and distribution of the Western an South coast of the Maracaibo Lake of the Zulia State, Venezuela. General aspects of the Ramon Laguna of ENELVEN fossil power plant are presented, as well as the environmental measures implanted in this power station to avoid detrimental effects on the environment that could be caused by the emission of combustion products without the appropriate control, such as particulate matter, sulfur oxides, nitrogen oxides and carbon oxides [Espanol] ENELVEN es una empresa de servicio electrico que cubre las areas de generacion, transmision y distribucion de la Costa Occidental y Sur del Lago de Maracaibo, del Estado Zulia, Venezuela. Se presentan aspectos generales de la planta termoelectrica Ramon Laguna de la empresa ENELVEN, asi como las medidas ambientales implantadas en esta central para evitar efectos adversos sobre el ambiente que pudieran producirse por la emision de productos de la combustion si no existiera el debido control, tales como: particulas, oxidos de azufre, oxidos de nitrogeno y oxidos de carbono

  6. Atmospheric emissions control at ENELVEN`s Ramon Laguna thermal power plant; Control de emisiones a la atmosfera en la central termoelectrica Ramon Laguna de ENELVEN

    Energy Technology Data Exchange (ETDEWEB)

    Rincon Rincon, Edis Rafael [Empresa de Servicio Electrico (ENELVEN), (Venezuela)

    1997-12-31

    ENELVEN is an electric utility that covers the areas of generation, transmission and distribution of the Western an South coast of the Maracaibo Lake of the Zulia State, Venezuela. General aspects of the Ramon Laguna of ENELVEN fossil power plant are presented, as well as the environmental measures implanted in this power station to avoid detrimental effects on the environment that could be caused by the emission of combustion products without the appropriate control, such as particulate matter, sulfur oxides, nitrogen oxides and carbon oxides [Espanol] ENELVEN es una empresa de servicio electrico que cubre las areas de generacion, transmision y distribucion de la Costa Occidental y Sur del Lago de Maracaibo, del Estado Zulia, Venezuela. Se presentan aspectos generales de la planta termoelectrica Ramon Laguna de la empresa ENELVEN, asi como las medidas ambientales implantadas en esta central para evitar efectos adversos sobre el ambiente que pudieran producirse por la emision de productos de la combustion si no existiera el debido control, tales como: particulas, oxidos de azufre, oxidos de nitrogeno y oxidos de carbono

  7. DISTRIBUSI HUTAN BAKAU DI LAGUNA PANTAI SELATAN YOGYAKARTA (Mangrove Distribution at the Lagoons in the Southern Coast of Yogyakarta

    Directory of Open Access Journals (Sweden)

    Tjut Sugandawaty Djohan

    2007-03-01

    Full Text Available ABSTRAK  Kehadiran sisa hutan bakau di laguna Bogowonto, pantai selatan Yogyakarta menunjukkan bahwa pada masa lalu laguna tersebut didominasi oleh hutan bakau, sehingga penelitian ini bertujuan mempelajari kehadiran vegetasi bakau di laguna-laguna dan muara sungai di pantai selatan tersebut. Ada empat laguna di pantai Selatan Yogyakarta, laguna Bogowonto, Serang, Progo, Opak, dan satu muara sungai, Kali Baron. Laguna tersebut merupakan laguna internitten, artinya pada musim kemarau, mulut sungainya tertutup gumuk pasir dan laguna didominasi oleh perairan tawar dan merupakan ekosistem tergenang. Sebaliknya di musim hujan mulut sungai terbuka, laguna bersifat sebagai ekosistem pasang surut. Data vegetasi dicuplik dengan menggunakan kuadrat plot berukuran 10m x 20m dengan ulangan dua kali. Kuadrat plot ditempatkan pada pusat distribusi mangrovenya, yang dipilih mulai dari rawa burit ke arah muara sungai. Tekstur tanah, hara tanah, salinitas air dan hara air juga dikaji. Kehadiran hutan bakau di laguna dibatasi oleh tekstur tanah. Tekstur pasir, 60-99 %, mendominasi laguna Serang, Progo, Opak dan muara kali Baron. Komunitas bakau hanya ditemukan di laguna Bogowonto, yang tersusun atas 5 jenis bakau, Sonneratia alba, Nypa fruticans, Acanthus ilicifolius, Acrosticum sp., dan Derris heterophylla, dan dua jenis spesies peralihan, Pandanus sp. dan Cynodon dactylon. Pola distribusi komunitasnya mengelompok (clump, mempunyai tipe riverine mangrove,dan tidak membentuk zonasi. Sonneratia hadir mulai dari muara sungai sampai di rawa burit. Ketika air surut salinitas berkisar antara 0-6,5 %. Nypa hanya ditemukan satu kelompok di kaki gumuk. Distribusi Sonneratia tidak ditentukan oleh tinggi genangan, akan tetapi tinggi pneumatophor mengikuti pola tinggi genangan air. Di laguna Bogowonto, spesies bakau tidak mempunyai zonasi dan beradaptasi pada sistem ekologinya.   ABSTRACT  The presence of mangrove remnant at the lagoon of Bogowonto River in the southern

  8. Deposition and Accumulation of Emerging Contaminants in the Sediments of the Palos Verde Shelf, California

    Science.gov (United States)

    Deposition and Accumulation of Emerging Contaminants in the Sediments of the Palos Verde Shelf, California Mark G. Cantwell, David R. Katz, Julia Sullivan, Robert P. Eganhouse, Monique M. Perron, Robert M. Burgess The Palos Verdes shelf is located off the Southern California coa...

  9. The Cape Verde Islands are home to a small and genetically distinct humpback whale breeding population

    NARCIS (Netherlands)

    Bérubé, Martine; Ryan, Conor; Berrow, Simon D.; Suarez, Pedro Lopez; Monteiro, Vanda; Wenzel, Frederick; Robbins, Jooke; Mattila, David; Vikingsson, G.A.; Øien, Nils; Palsboll, Per

    2013-01-01

    The Cape Verde Islands appear to be winter breeding ground of the smallest humpback whale population yet known. However, it is unclear whether the humpback whales at the Cape Verde Islands interbreed with those in the West Indies. Here we present the results of the genetic analysis of 50 humpback

  10. 76 FR 1197 - Arizona Public Service Company, Palo Verde Nuclear Generating Station; Notice of Availability of...

    Science.gov (United States)

    2011-01-07

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-528, 50-529, 50-530; NRC-2009-0012] Arizona Public Service Company, Palo Verde Nuclear Generating Station; Notice of Availability of the Final Supplement 43... of operation for the Palo Verde Nuclear Generating Station (PVNGS). Possible alternatives to the...

  11. Cape Verde. A Country Guide Series Report from the AACRAO-AID Project.

    Science.gov (United States)

    Sevigny, Joseph A.

    This report provides information on the education system of Cape Verde, and is designed to assist college admissions officers and registrars in the United States with the admission and placement of students from that country. The report contains general information on the geography, history, and people of Cape Verde, as well as more specific…

  12. Mesa Verde--A Year-Round High School. A Descriptive Report of 1980-81.

    Science.gov (United States)

    Housden, Terry; Holmes, Lynda

    Mesa Verde High School was constructed in 1974 and is the last high school built in the San Juan (California) Unified District. It serves students in grades 9 through 12 and has an open enrollment policy. Mesa Verde operates on a year-round schedule with students divided into three tracks. Basically, each track is in session for 9 weeks and then…

  13. 75 FR 48323 - Agency Information Collection Activities; Proposed Collection; Comment Request; Palos Verdes...

    Science.gov (United States)

    2010-08-10

    ..., quantity, and/or cooking method of fish species, (3) gather quantitative data that can be used to... anglers who fish in the Palos Verdes Shelf vicinity. Title: Palos Verdes Shelf Seafood Consumption Survey... deep for direct human contact; however, fish in the PV Shelf area bioaccumulate the contaminants...

  14. Botanical ecology and conservation of the Laguna de la Herrera (Sabana de Bogotá, Colombia Botanical ecology and conservation of the Laguna de la Herrera (Sabana de Bogotá, Colombia

    Directory of Open Access Journals (Sweden)

    Wijninga V. M.

    1989-09-01

    Full Text Available The acuatic, helophytic and pleustophytic vegetation of the Laguna de La Herrera, on the southwestern border of the high plain of Bogotá at 2550 m was studied following the Zurich- Montpellier approach. The communities recognized were: terrestrial community of Phytolacca bogotensis; helophytic communities of scirpus californicus and Typha angustifolia ; scirpus californicus ; Polygonum punctatum ; Rumex obtusifolius with Polygonum punctatum; Bidens laevis ; Hydrocotyle ranunculoides. Pleustophytic communities of Limnobium laevigatum; Azolla filiculoides with Lemna cf. gibba and Eichornia crassipes. The structure, floristic composition and ecological aspects were also considered. Several recommendations about conservation of the Laguna are given. Se estudió la vegetación alrededor de la Laguna de La Herrera, una laguna andina a 2550 m. Se diferenciaron una comunidad de Phytolacca bogotensis (1: comunidades helofíticas dominadas por: Scirpus californicus y Typha angustifolia (2; Scirpus californicus (3; Polygonum punctatum (4; Rumex obtusifolius y Polygonum punctatum (5; Bidens laevis (6; Hydrocotyle ranunculoides (7; comunidades pleustofíticas con: Limnobium laevigatum; (8; Azolla filiculoides y Lemna cf. gibba (9 y Eichhornia crassipes (10. Se registraron la estructura, composición florística, los rasgos ecológicos y la distribución de las comunidades y se comparó con la conductividad eléctrica y la calidad del agua. Finalmente, se hacen recomendaciones para la conservación de la laguna y la vegetación acuática.

  15. Subsidence of the Laguna Salada Basin, northeastern Baja California, Mexico, inferred from Milankovitch climatic changes

    Energy Technology Data Exchange (ETDEWEB)

    Contreras, Juan; Martin-Barajas, Arturo [Departamento de Geologia, CICESE, Ensenada Baja California (Mexico); Herguera, Juan Carlos [Division de Oceanologia, CICESE, Ensenada Baja California (Mexico)

    2005-01-15

    Laguna Salada in northern Baja California, Mexico, is an active half-graben product of the trans-tensional tectonics of the Gulf of California. It is sensitive to changes in sediment supply from the Colorado River basin. We present a time series analysis of the upper 980 m of a gamma-ray log from a borehole drilled near the Laguna Salada fault. The power spectrum of the gammaray log resembles the spectrum of {delta}{sup 1}8{omicron} Pleistocene isotopic variations from ice cores and from the deep ocean, known to be strongly controlled by Milankovitch cycles. We correlate {delta}{sup 1}8{omicron} stages with silty and sandy intervals in the log. Downcore ages for the last 780 ky are constrained within {approx}10 kyr. We derive a simple time vs. depth calibration relation for the basin over this time interval. Estimated sedimentation rates at the drill site appear to be constant with a value of {approx}1.6 mm/yr. We propose that this subsidence rate is produced by the Laguna Salada fault. [Spanish] La cuenca de Laguna Salada en el norte de Baja California, Mexico, es un semigraben activo producto de la tectonica ranstensional del Golfo de California. Esta cuenca endorreica es sensible a cambios en sedimentacion por variaciones en el aporte e sedimentos de fuentes cercanas y distales transportados por arroyos de las sierras adyacentes y por el Rio Colorado. Esta cuenca es un sitio excepcional para explorar el uso de cambios climaticos ciclicos como herramienta de datacion y estimar tasas de sedimentacion y subsidencia en el area. Para demostrar esto se presenta un analisis de series de tiempo de un registro de rayos de gama de un pozo geotermico exploratorio perforado adyacente a la falla de Laguna Salada, la cual limita el margen oriental de la cuenca. Los resultados del analisis indican que el espectro de los primeros 980 m del registro de rayos gama tiene una alta coherencia con el espectro de registros isotopicos paleoclimaticos de {delta}{sup 1}8{omicron} del

  16. Charpy V, an application in Mat lab

    International Nuclear Information System (INIS)

    Castillo M, J.A.; Torres V, M.

    2003-01-01

    The obtained results with the system Charpy V V 1 designed in Mat lab for the estimate of parameters of three mathematical models are shown. The adjustment of data is used to determine the fracture energy, the lateral expansion and the percentage of ductility of steels coming from the reactor vessels of Laguna Verde, Veracruz. The data come from test tubes type Charpy V of irradiated material and not irradiated. To verify our results they were compared with those obtained by General Electric of data coming from the Laguna Verde nuclear power plant. (Author)

  17. Charpy V, an application in Mat lab; Charpy V, una aplicacion en Matlab

    Energy Technology Data Exchange (ETDEWEB)

    Castillo M, J.A.; Torres V, M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    The obtained results with the system Charpy V{sub V}1 designed in Mat lab for the estimate of parameters of three mathematical models are shown. The adjustment of data is used to determine the fracture energy, the lateral expansion and the percentage of ductility of steels coming from the reactor vessels of Laguna Verde, Veracruz. The data come from test tubes type Charpy V of irradiated material and not irradiated. To verify our results they were compared with those obtained by General Electric of data coming from the Laguna Verde nuclear power plant. (Author)

  18. Response to IPE and IPEEE results at Palo Verde NGS

    International Nuclear Information System (INIS)

    Lindquist, R.C.

    1992-01-01

    Insights gained from the internal events probabilistic risk assessment (PRA) and from the pilot plant demonstration of the fire-induced vulnerability evaluation (FIVE) have been used to initiate corrective actions in the form of administrative controls, compensatory measures, and plant modifications to reduce the risks associated with significant core-damage sequences. Palo Verde was a pilot demonstration plant for the FIVE methodology developed by the Electrical Power Research Institute and sponsored by the Nuclear Utility Management and Resources Council. Several findings emerged from the application of FIVE and have been acted upon to reduce the impact of fire in several compartments of the plant

  19. Groundwater arsenic in the Verde Valley in central Arizona, USA

    International Nuclear Information System (INIS)

    Foust, R.D.; Mohapatra, P.; Compton-O'Brien, A.-M.; Reifel, J.

    2004-01-01

    Forty-one water samples were collected and analyzed from throughout the Verde Valley watershed to identify the source of As in well water used for domestic and agricultural purposes. Each water sample was analyzed for anions, cations and trace chemical constituents by atomic absorption spectroscopy, anion chromatography and traditional wet chemical procedures. Arsenic concentrations ranged from 10 to 210 μg/l, with the highest values observed for water pooled on tailings from an abandoned Cu mine. Geostatistical analysis of the data revealed the primary source of As to be groundwater in contact with the Supai and Verde formations, as opposed to runoff from the abandoned mine tailings. Montezuma Well, a collapsed travertine spring, contained the highest levels of naturally occurring As (> 100 μg/l). Arsenic in Montezuma Well water was shown to be 100% arsenate. X-ray absorbance near edge spectra (XANES) of Potomogeton illinoiensis, an endemic plant species of Montezuma Well, demonstrate that As is absorbed as arsenate, reduced to arsenite in the plant and retained as an organic glutathione complex. XANES spectra of Montezuma Well sediments show 4 forms of As present: arsenate (∼54%), As(III)-glutathione complex (∼32%) and an As-organic complex (∼14%) containing dimethylarsinic acid and arsenobetaine. This is the first report of As(III)-glutathione in sediments

  20. Update-processing steam generator cleaning solvent at Palo Verde

    International Nuclear Information System (INIS)

    Peters, G.

    1996-01-01

    Framatome Technologies Inc.(FTI) recently completed the steam generator chemical cleanings at the Palo Verde Nuclear Generating Station Units 1, 2 and 3. Over 500,000 gallons of low-level radioactive solvents were generated during these cleanings and were processed on-site. Chemical cleaning solutions containing high concentrations of organic chelating wastes are difficult to reduce in volume using standard technologies. The process that was ultimately used at Palo Verde involved three distinct processing steps: The evaporation step was conducted using FTI's submerged combustion evaporator (SCE) that has also been successfully used at Arkansas Nuclear One - Unit 1, Three Mile Island - Unit 1, and Oconee on similar waste. The polishing step of the distillate used ultrafiltration (UF) and reverse osmosis (RO) technology that was also used extensively by Ontario Hydro to assist in their processing of chemical cleaning solvent. This technology, equipment, and operations personnel were provided by Zenon Environmental, Inc. The concentrate from the evaporator was absorbed with a special open-quotes peat mossclose quotes based media that allowed it to be shipped and buried at the Environcare of Utah facility. This is the first time that this absorption media or burial site has been used for chemical cleaning solvent

  1. Geotourism, Medical Geology and local development: Cape Verde case study

    Science.gov (United States)

    Rocha, F.; Ferreira da Silva, E.

    2014-11-01

    Geotourism and Geoparks in particular are real opportunities to rural developments promoting the rate decline of unemployment and emigration through engaging the local communities in geopark activities and tourism marketing in the form of adventure tourism, ecotourism, rural tourism and health geotourism. Geotourism is closely linked with Medical Geology. The intake of minerals and chemical elements for food, water, soil (through geophagy) or dust can be accomplished by ingestion, inhalation or dermal absorption. Pelotherapy or “Mudtherapy” is the use of mud/clay for therapeutic applications, internal or external. Cape Verde archipelago is located in Atlantic ocean, 400 km westwards of Senegal coast. Geotourism is being developed, mainly focused on the development of a geopark in Fogo island huge caldera, but also trying to take advantage of their potentialities for Geomedecine. A cooperative program established between Cape Verde University (UCV) and Aveiro University (UA, Portugal) is under way, aiming, on a first stage, to identify Geotouristic potentialities and, on a second stage, to develop products. Geotourism is being developed, mainly focused on the development of a geopark in Fogo isl. huge caldera, but also trying to take advantage of their potentialities for Geomedecine.

  2. Groundwater arsenic in the Verde Valley in central Arizona, USA

    Energy Technology Data Exchange (ETDEWEB)

    Foust, R.D.; Mohapatra, P.; Compton-O' Brien, A.-M.; Reifel, J

    2004-02-01

    Forty-one water samples were collected and analyzed from throughout the Verde Valley watershed to identify the source of As in well water used for domestic and agricultural purposes. Each water sample was analyzed for anions, cations and trace chemical constituents by atomic absorption spectroscopy, anion chromatography and traditional wet chemical procedures. Arsenic concentrations ranged from 10 to 210 {mu}g/l, with the highest values observed for water pooled on tailings from an abandoned Cu mine. Geostatistical analysis of the data revealed the primary source of As to be groundwater in contact with the Supai and Verde formations, as opposed to runoff from the abandoned mine tailings. Montezuma Well, a collapsed travertine spring, contained the highest levels of naturally occurring As (> 100 {mu}g/l). Arsenic in Montezuma Well water was shown to be 100% arsenate. X-ray absorbance near edge spectra (XANES) of Potomogeton illinoiensis, an endemic plant species of Montezuma Well, demonstrate that As is absorbed as arsenate, reduced to arsenite in the plant and retained as an organic glutathione complex. XANES spectra of Montezuma Well sediments show 4 forms of As present: arsenate ({approx}54%), As(III)-glutathione complex ({approx}32%) and an As-organic complex ({approx}14%) containing dimethylarsinic acid and arsenobetaine. This is the first report of As(III)-glutathione in sediments.

  3. ¿Qué tan verde es tu mercado?

    Directory of Open Access Journals (Sweden)

    Wilmar R. Olaya-González

    2011-01-01

    Full Text Available El mercado de lo verde y lo ecológico es una tendencia indiscutible en nuestro mundo globalizado, que busca de alguna manera resarcir el daño infringido sobre el medio ambiente. Más allá de simple altruismo, la ecología se ha convertido en una moda, de la cual unos y otros toman ventaja a su mejor acomodo, haciendo del mercado de productos y servicios su tribuna; eco-diseño, planes de responsabilidad social y ambiental, campañas por el reciclaje y consumo de productos "más amigables" con el medio ambiente hacen parte del panorama que se intenta describir en esta reseña. Por medio de un estudio de caso, se hará énfasis en cómo la comunicación asume un papel crucial en la verdadera apropiación del concepto de "consumidor verde" y "consumidor responsable", de manera que la propuesta transversal de las tic se convierta en una herramienta no solo tecnológica, sino también de empoderamiento del papel que la sociedad puede representar en el cuidado de los recursos naturales.

  4. Estudios ecológicos en el Páramo de Cruz Verde, Colombia II. Las comunidades vegetales Estudios ecológicos en el Páramo de Cruz Verde, Colombia II. Las comunidades vegetales

    Directory of Open Access Journals (Sweden)

    Lozano Contreras Gustavo

    1976-09-01

    Full Text Available Im Páramo de Cruz Verde, Cundinamarca, Kolumbien (3.400m Höhe werden auf Grund pflanzensoziologischer Untersuchungen mehrere Pflanzengemeinschaften unterschieden. Am verbreitetsten sind solche, die ihre Existenz anthropogenen Einflüssen verdanken und sich unter diesen stabilisiert haben; sie werden als Subklimax-Gesellschaften aufgefaΒt und zeichnen sich durch ihre geringe Empfindlichkeit gegen gelegentliche Brände aus. Hierzu sind zu rechnen: eine Calamagrostis effusa - Espeletia grandiflora - Geranium santanderiense - Gesellschaft, eine Calamagrostis effusa - Espeletia grandiflora - Geranium multiceps - Gesellschaft, eine Calamagrostis effusa - Spiranthes vaginata - Gesellschaft, eine Calamagrostis effusa «Espeletia corymbosa - Gesellschaft und eine Calamagrostis effusa - Altesteinia fimbriata - Gesellschaft.In Gebieten, deren Vegetation durch natürliche (z. B. Erdrutsche oder anthropogene Einflüsse (z, B. vorübergehender Ackerbau zerstört wurde, stellen sich Pionier-Gesellschaften mit Espeletia argentea ein.  Da in allen unterschiedenen Subklimax-Gesellschaften Baum - undBusch-Arten vorkommen, die für kleinere Busch waldbestände typisch sind, werden letztere als Reste einer Klimax-Vegetation angesehen, die nur an ständig sumpfigen Stellen durch eine Diplostephium revolutum Gesell-schaft ersetzt wird. Letztere ist noch heute an vielen Stellen erhalten; sie wird wenigstens teilweise als Endstadium einer Sukzessionsreihe angesehen,die während der Verlandung von kleinen Seen (meist glazialer Herkunft auftrat.  Als wesentliche Ursachen der räumlichen Verteilung der heute dominierenden Subklimax-Gesellschaften werden die örtlich unterschiedlich stark schwankenden Bodenwassergehalte diskutiert.En el Páramo de Cruz Verde, Cundinamarca, Colombia (3.400 m de altura se distinguen varias comunidades vegetales con base en estudios fitosociológicos. Distribución más amplia tienen aquellas que deben su existencia a las influencias

  5. To report the obtained results in the operation multicycle study of the L V U-1 using design data with the FCSII (1D) and PRESTO (3D) codes of the FMS system

    International Nuclear Information System (INIS)

    Montes T, J.L.; Cortes C, C.C.

    1991-07-01

    This work is to carry out a multicycle study for the Laguna Verde U-1 reactor with the FCS-II (1 - 20 cycles) and PRESTO (1 - 6 cycles) codes and to compare the obtained results against those reported by General Electric. (Author)

  6. Application of the Scandpower methodology for the pattern design of the control bars at full power in the cycle 1 of the CNLV; Aplicacion de la metodologia de Scandpower para el diseno de patrones de barras de control a plena potencia en el ciclo uno de la CNLV

    Energy Technology Data Exchange (ETDEWEB)

    Montes T, J L; Perusquia C, R [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1992-05-15

    The objective of this report is by means of the methodology provided by Scandpower to design a group of patterns of control bars to full power for the operation of the first operation cycle of the Laguna Verde Unit 1 reactor. (Author)

  7. To report the obtained results in the operation multicycle study of the L V U-1 using design data with the FCSII (1D) and PRESTO (3D) codes of the FMS system; Reportar los resultados obtenidos en el estudio de multiciclos de operacion de LV U-1 utilizando datos de diseno con los codigos FCSII (1D) y PRESTO (3D) del sistema FMS

    Energy Technology Data Exchange (ETDEWEB)

    Montes T, J L; Cortes C, C C

    1991-07-15

    This work is to carry out a multicycle study for the Laguna Verde U-1 reactor with the FCS-II (1 - 20 cycles) and PRESTO (1 - 6 cycles) codes and to compare the obtained results against those reported by General Electric. (Author)

  8. Analysis of the 3 and 4 cycles with extensions in the operation of the CNLV U-1; Analisis de los ciclos 3 y 4 con extensiones en la operacion de la CNLV U-1

    Energy Technology Data Exchange (ETDEWEB)

    Montes T, J.L.; Torres A, C.; Perusquia C, R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1992-08-15

    The objective of the report is the comparison of the radial distributions of burned in the core among the results of the simulation of the Laguna Verde Central U-1 reactor during the operation of the cycles 1 to 4 and the data of the operation with information provided by the fuel supplier. (Author)

  9. Application of the Scandpower methodology for the pattern design of the control bars at full power in the cycle 1 of the CNLV

    International Nuclear Information System (INIS)

    Montes T, J.L.; Perusquia C, R.

    1992-05-01

    The objective of this report is by means of the methodology provided by Scandpower to design a group of patterns of control bars to full power for the operation of the first operation cycle of the Laguna Verde Unit 1 reactor. (Author)

  10. Analysis of the 3 and 4 cycles with extensions in the operation of the CNLV U-1

    International Nuclear Information System (INIS)

    Montes T, J.L.; Torres A, C.; Perusquia C, R.

    1992-08-01

    The objective of the report is the comparison of the radial distributions of burned in the core among the results of the simulation of the Laguna Verde Central U-1 reactor during the operation of the cycles 1 to 4 and the data of the operation with information provided by the fuel supplier. (Author)

  11. Aves ocasionales en la Sabana de Bogotá y las Lagunas de Fúquene y de Tota

    Directory of Open Access Journals (Sweden)

    Borrero José Ignacio

    1947-12-01

    Full Text Available En números anteriores de esta misma revista publiqué algunas listas preliminares anotando la presencia ocasional de ciertas aves en la Sabana de Bogotá y la Laguna de Fúquene. A continuación hago mención de otras especies que he encontrado en las mismas localidades o también en la Laguna de Tota, Boyacá, a 3015 metros de altitud. Por considerarlo de importancia desde el punto de vista de la distribución geográfica, doy también datos referentes a la presencia de un ave migratoria norteamericana (Colymbus niqricollis californicus en la Laguna de Tota.

  12. Contaminación producida por piscicultura intensiva en lagunas andinas de Junín, Perú

    Directory of Open Access Journals (Sweden)

    Mauro Mariano

    2011-05-01

    Full Text Available Se reportan los cambios producidos por el cultivo intensivo de la trucha Oncorhynchus mykiss en siete lagunas andinas. Las observaciones se realizaron en el año 1996, y entre el 2002 - 2007 y permitieron observar el proceso de deterioro de las lagunas, caracterizado por el incremento en las concentraciones de fosforo total y la disminución del oxigeno disuelto y la transparencia. La comunidad béntica fue evaluada en las siete lagunas en el 2007, resultando el número de especies y los índices de diversidad bajos (H'<1,26; <8 spp.. La abundancia varió entre 7 y 35 ind./0,04m2. La materia orgánica y carbonatos en fondo fueron altos (30,22 - 42,45%.

  13. Eficiencia del tratamiento de residuales porcinos en digestores de laguna tapada

    Directory of Open Access Journals (Sweden)

    D Blanco

    Full Text Available Se evaluó la eficiencia de dos lagunas tapadas, diseñadas para tratar los residuales de las granjas porcinas P-3 y T-2.1 _pertenecientes a la Asociación de Porcicultores de Yucatán, México_, con el objetivo de verificar la factibilidad de implementar en Cuba esta tecnología. Los indicadores físico-químicos y microbiológicos de los efluentes fueron determinados en el momento de su entrada y su salida de los digestores, y a su salida del lago de estabilización. El digestor de la granja P-3 logró remover más del 90 % de la demanda química de oxígeno (DQO y hasta el 71 % de los sólidos suspendidos totales (SST presentes; mientras que el digestor de la granja T-2.1 alcanzó una remoción del 78 % en la DQO y el 62 % de los SST. Los análisis sanitarios indicaron que las bacterias coliformes totales presentaron una disminución importante, de 2,4 x 108 a 1,7 x 103 en la granja P-3 y de 4,2 x 107 a 2,7 x 103 en la granja T-2.1. En ambas lagunas, los huevos de helmintos mostraron una reducción del 100 %. Se concluye que las lagunas tapadas tuvieron un adecuado desempeño en el tratamiento de los residuales porcinos, y que esta tecnología es factible de ser empleada en Cuba.

  14. DETERMINACIÓN DE LOS METALES PESADOS EN LA LAGUNA CHOQUENE, QUILCAPUNCO – PUTINA – PUNO

    OpenAIRE

    Machaca Hancco, Ernesto Samuel; Universidad Nacional del Altiplano

    2013-01-01

    El presente trabajo de investigación  se ha efectuado en la mina Regina Palca 11, con el objetivo de determinar la concentración de los metales pesados y el grado de toxicidad en la Laguna Choquene Quilcapunco Putina. La  metodología  aplicada fue analítica experimental y descriptiva de las tareas de investigación propuesta en el presente trabajo en los tres puntos de muestreo. El comportamiento geoquímico de los metales pesados (de arsénico, cobre, plomo, plata), en los diques de colas y esc...

  15. Environmental geology of Laguna de las Perdices, Monte, Buenos Aires, Argentina

    OpenAIRE

    Dangavs, Nauris Vitauts

    2009-01-01

    El estudio de la laguna de las Perdices abarca tres aspectos: el geolimnológico, el geoambiental y el de remediación. El primero ha consistido en caracterizar el medio físico de un ambiente léntico típico de la Pampasia meridional prácticamente desconocido. El segundo, la evaluación del grado de deterioro natural y la contaminación físico-química y bacteriológica. El tercero propicia las medidas para su recuperación, máxime teniendo en cuenta que el Municipio de Monte pretende transformarla e...

  16. Geología ambiental de la laguna de las Perdices, Monte, Buenos Aires, Argentina

    OpenAIRE

    Nauris Dangavs

    2010-01-01

    El estudio de la laguna de las Perdices abarca tres aspectos: el geolimnológico, el geoambiental y el de remediación. El primero ha consistido en caracterizar el medio físico de un ambiente léntico típico de la Pampasia meridional prácticamente desconocido. El segundo, la evaluación del grado de deterioro natural y la contaminación físico-química y bacteriológica. El tercero propicia las medidas para su recuperación, máxime teniendo en cuenta que el Municipio de Monte pretende transformarla e...

  17. Salida de campo a Laguna de Duero (Valladolid) el 14 de febrero de 1951

    OpenAIRE

    Valverde Gómez, José Antonio, 1926-2003

    2008-01-01

    Salida de campo a Laguna de Duero, en la provincia de Valladolid, durante la mañana del 14 de febrero de 1951, de la que se anotaron observaciones sobre las siguientes aves: Accipiter nisus (Gavilán común, también llamado Astur palumbarius por el autor), Anas penelope (Silbón europeo), Anas platyrhynchos (Ánade azulón), Anser anser (Ánsar común), Anthus sp. (Bisbita), Ciconia ciconia (Cigüeña blanca), Clamator glandarius (Críalo europeo), Coccothraustes coccothraustes (Picogordo), Corvus coro...

  18. Niebla ceruchis from Laguna Figueroa: dimorphic spore morphology and secondary compounds localized in pycnidia and apothecia

    Science.gov (United States)

    Enzien, M.; Margulis, L.

    1988-01-01

    During and after the floods of 1979-80 Niebla ceruchis growing epiphytically on Lycium brevipes was one of the dominant aspects of the vegetation in the coastal dunal complex bordering the microbial mats at Laguna Figueroa, Baja California Norte, Mexico. The lichen on denuded branches of Lycium was far more extensively distributed than Lycium lacking lichen. Unusual traits of this Niebla ceruchis strain, namely localization of lichen compounds in the mycobiont reproductive structures (pycnidia and apothecia) and simultaneous presence of bilocular and quadrilocular ascospores, are reported. The abundance of this coastal lichen cover at the microbial mat site has persisted through April 1988.

  19. Rock Magnetic Properties of Laguna Carmen (Tierra del Fuego, Argentina): Implications for Paleomagnetic Reconstruction

    Science.gov (United States)

    Gogorza, C. G.; Orgeira, M. J.; Ponce, F.; Fernández, M.; Laprida, C.; Coronato, A.

    2013-05-01

    We report preliminary results obtained from a multi-proxy analysis including paleomagnetic and rock-magnetic studies of two sediment cores of Laguna Carmen (53°40'60" S 68°19'0" W, ~83m asl) in the semiarid steppe in northern Tierra del Fuego island, Southernmost Patagonia, Argentina. Two short cores (115 cm) were sampled using a Livingstone piston corer during the 2011 southern fall. Sediments are massive green clays (115 to 70 cm depth) with irregularly spaced thin sandy strata and lens. Massive yellow clay with thin sandy strata continues up to 30 cm depth; from here up to 10 cm yellow massive clays domain. The topmost 10 cm are mixed yellow and green clays with fine sand. Measurements of intensity and directions of Natural Remanent Magnetization (NRM), magnetic susceptibility, isothermal remanent magnetization, saturation isothermal remanent magnetization (SIRM), back field and anhysteretic remanent magnetization at 100 mT (ARM100mT) were performed and several associated parameters calculated (ARM100mT/k and SIRM/ ARM100mT). Also, as a first estimate of relative magnetic grain-size variations, the median destructive field of the NRM (MDFNRM), was determined. Additionally, we present results of magnetic parameters measured with vibrating sample magnetometer (VSM). The stability of the NRM was analyzed by alternating field demagnetization. The magnetic properties have shown variable values, showing changes in both grain size and concentration of magnetic minerals. It was found that the main carrier of remanence is magnetite with the presence of hematite in very low percentages. This is the first paleomagnetic study performed in lakes located in the northern, semiarid fuegian steppe, where humid-dry cycles have been interpreted all along the Holocene from an aeolian paleosoil sequence (Orgeira et el, 2012). Comparison between paleomagnetic records of Laguna Carmen and results obtained in earlier studies carried out at Laguna Potrok Aike (Gogorza et al., 2012

  20. Options for In Situ Capping of Palos Verdes Shelf Contaminated Sediments

    National Research Council Canada - National Science Library

    Palermo, Michael; Schroeder, Paul; Rivera, Yilda; Ruiz, Carlos; Clarke, Doug; Gailani, Joe; Clausner, James; Hynes, Mary; Fredette, Thomas; Tardy, Barbara

    1999-01-01

    The U.S. Army Engineer Waterways Experiment Station (WES) has performed an evaluation of in situ capping options for sediment restoration of DDT and PCB contaminated sediments on the Palos Verdes (PV...

  1. NPDES Permit for Mesa Verde National Park Water Treatment Plant in Colorado

    Science.gov (United States)

    Under NPDES permit number CO-0034462, the United States Department of the Interior, National Park Service is authorized to discharge from the Mesa Verde National Park water treatment plant, in Montezuma County, Colo.

  2. Effects of past and future groundwater development on the hydrologic system of Verde Valley, Arizona

    Science.gov (United States)

    Garner, Bradley D.; Pool, D.R.

    2013-01-01

    Communities in central Arizona’s Verde Valley must manage limited water supplies in the face of rapidly growing populations. Developing groundwater resources to meet human needs has raised questions about the effects of groundwater withdrawals by pumping on the area’s rivers and streams, particularly the Verde River. U.S. Geological Survey hydrologists used a regional groundwater flow model to simulate the effects of groundwater pumping on streamflow in the Verde River. The study found that streamflow in the Verde River between 1910 and 2005 had been reduced as the result of streamflow depletion by groundwater pumping, also known as capture. Additionally, using three hypothetical scenarios for a period from 2005 to 2110, the study’s findings suggest that streamflow reductions will continue and may increase in the future.

  3. The role of eclogite in the mantle heterogeneity at Cape Verde

    DEFF Research Database (Denmark)

    Barker, Abigail Katrine; Holm, Paul Martin; Troll, Valentin R.

    2014-01-01

    The Cape Verde hotspot, like many other Ocean Island Basalt provinces, demonstrates isotopic heterogeneity on a 100–200 km scale. The heterogeneity is represented by the appearance of an EM1-like component at several of the southern islands and with a HIMU-like component present throughout...... have been limited. We apply the minor elements in olivine approach (Sobolev et al. in Nature 434:590–597, 2005; Science, doi:10.1126/science.1138113, 2007), to determine and quantify the contributions of peridotite, pyroxenite and eclogite melts to the mantle heterogeneity observed at Cape Verde. Cores...... of olivine phenocrysts of the Cape Verde volcanics have low Mn/FeO and low Ni*FeO/MgO that deviate from the negative trend of the global array. The global array is defined by mixing between peridotite and pyroxenite, whereas the Cape Verde volcanics indicate contribution of an additional eclogite source...

  4. New species of Rissoidae from the Cape Verde Islands (Mollusca: Gastropoda) Part 1

    OpenAIRE

    Moolenbeek, R.G.; Rolán, E.

    1988-01-01

    Sediment samples collected at the Cape Verde Islands contained many interesting micromolluscs. Amongst them, four new species of the family Rissoidae ( Alvania peli, A. nicolauensis, A. stocki and A. planciusi).

  5. Techos verdes: una alternativa ecológica

    Directory of Open Access Journals (Sweden)

    Maureen Trebilcock Kelly

    2001-06-01

    Full Text Available Es un hecho que estamos pavimentando nuestro Planeta. Durante el siglo XX, hemos construido aceleradamente ciudades y carreteras, cubriendo y destruyendo, en este proceso, nuestra tierra. Este hecho es más evidente en las áreas urbanas, que aparecen sobrepavimentadas, donde la vegetación cubre apenas un tercio de la superficie, comparado con un 75 a 95% de las áreas rurales. En Chile, las áreas urbanas crecen sin límite aparente, especialmente nuestra capital, con escasez de áreas verdes y con un alarmante aumento en los niveles de contaminación atmosférica y acústica.

  6. O golfe e os rumos do Cabo Verde independente = Golfing and the independent Cape Verde directions = El golf y los caminos del Cabo Verde independiente

    Directory of Open Access Journals (Sweden)

    Melo, Victor Andrade de

    2016-01-01

    Full Text Available Em função de uma série de peculiaridades, o golfe tem desempenhado um importante papel na história de Cabo Verde. A prática, que tem uma longa trajetória no arquipélago, em diversas ocasiões foi mobilizada a fim de materializar a ideia de que o cabo-verdiano era portador de um alto padrão civilizacional. No período colonial, essa foi uma das estratégias pelos nativos usada para lidar com o jugo da metrópole, argumento utilizado para requisitar maior respeito às especificidades e atenção às necessidades locais. O que terá mudado nas considerações sobre esse esporte quando chegou a independência (1975? Que diferenças podem ser sentidas nas décadas seguintes? Neste artigo, argumentamos que os discursos sobre a modalidade nos ajudam a lançar um olhar sobre os debates acerca dos rumos do país insular nos últimos 40 anos

  7. Fitoplancton y aspectos físicos y químicos de la laguna de Chingaza en Cundinamarca, Colombia Fitoplancton y aspectos físicos y químicos de la laguna de Chingaza en Cundinamarca, Colombia

    Directory of Open Access Journals (Sweden)

    Donato R. John Charles

    1991-12-01

    Full Text Available En la laguna de Chingaza (3265 m alt. Cordillera Oriental Colombiana, se realizaron muestreos de fitoplancton, mediciones de temperatura, oxígeno y parámetros físicos y químicos. La comunidad de fitoplancton comprende principalmente Desmidiaceae, Bacillariophyceae, y Cyanophyceae: La Desmidiacea Closterium sp. es la dominante durante la mayor parte del muestreo, pero en octubre (1989 la Cianofícea Oscillatoria sp. es la más significativa. En esta misma época la laguna presenta estratificación térmica y deficiencia de nitrógeno en sus aguas. Debido a los bajos valores en la relación nitrógeno/fósforo, conductividad, sólidos disueltos, acidez y ciertos organismos indicadores la laguna de chingaza es oligotrófica. At the Chingaza pond (3.265 m alt., located on the eastern Colombian cordillera, samples and measurements of temperature, oxygen, and physical-chemical parameters were taken. Phytoplankton community mainly consisted of Desmidiaceae, Bacillariophyceae, and Cyanophceae. Desmidiaceae species dominated in most samples, but in october (1989 Oscillatoria sp. (Cyanophyceae was the most abundant species. During the latter period the laguna exhibited strong thermal stratification and its inorganic nitrogen content was extremely low. It is believed that this is a good example of an oligotrophic pond given the presence of certain bioindicators, the low nitrogen/phosphorus ratio, conductivity, and quantity of suspended solids.

  8. Estrategias de mercadeo verde utilizadas por empresas a nivel mundial

    Directory of Open Access Journals (Sweden)

    Castellano, Susie

    2015-09-01

    Full Text Available La preocupación por el medio ambiente se ha convertido en una temática que inquieta a toda la colectividad actual, desde los más pequeños hasta los más grandes, desde la pequeña empresa hasta la gran industria. Sumado a esto, el auge de normativas ambientales que establecen regulaciones al empresario, los obliga a tener una mayor conciencia de los daños que pueden causar sus acciones al medio ambiente. Es por esto, que paulatinamente ha comenzado, por parte de las empresas, la adopción de estrategias en el área de mercadeo verde que les permita comercializar sus productos y servicios de forma que los mismos sean ambientalmente compatibles. En el presente trabajo, se abordaron las diferentes estrategias que han venido asumiendo empresas de diferente índole para hacer frente a tan importante filosofía en el ámbito mundial. Para tal fin, se hizo la revisión y contrastación de artículos escritos en el marco del mercadeo verde por Rivera y Molero (2006, Chamorro (2001, Samper y Echeverri (2008 principalmente, encontrándose que cada vez son más las empresas que se suman a esta forma de mercadear sus procesos y productos y más los consumidores que anteponen criterios ecológicos ante variables de otra índole, modificando sus hábitos de consumo.

  9. Environmental evidence of fossil fuel pollution in Laguna Chica de San Pedro lake sediments (Central Chile)

    Energy Technology Data Exchange (ETDEWEB)

    Chirinos, L. [Centro de Ciencias Ambientales EULA-Chile, Universidad de Concepcion, PO Box 160-C, Concepcion (Chile)]. E-mail: lchirin@pucp.edu.pe; Rose, N.L. [Environmental Change Research Centre, University College London, 26 Bedford Way, London WG1HOAP (United Kingdom); Urrutia, R. [Centro de Ciencias Ambientales EULA-Chile, Universidad de Concepcion, PO Box 160-C, Concepcion (Chile); Munoz, P. [Departamento de Biologia Marina, Universidad Catolica del Norte, Larrondo 1281, Coquimbo (Chile); Torrejon, F. [Centro de Ciencias Ambientales EULA-Chile, Universidad de Concepcion, PO Box 160-C, Concepcion (Chile); Torres, L. [Departamento de Botanica, Universidad de Concepcion, Concepcion (Chile); Cruces, F. [Departamento de Botanica, Universidad de Concepcion, Concepcion (Chile); Araneda, A. [Centro de Ciencias Ambientales EULA-Chile, Universidad de Concepcion, PO Box 160-C, Concepcion (Chile); Zaror, C. [Facultad de Ingenieria Quimica, Universidad de Concepcion, Concepcion (Chile)

    2006-05-15

    This paper describes lake sediment spheroidal carbonaceous particle (SCP) profiles from Laguna Chica San Pedro, located in the Biobio Region, Chile (36{sup o} 51' S, 73{sup o} 05' W). The earliest presence of SCPs was found at 16 cm depth, corresponding to the 1915-1937 period, at the very onset of industrial activities in the study area. No SCPs were found at lower depths. SCP concentrations in Laguna Chica San Pedro lake sediments were directly related to local industrial activities. Moreover, no SCPs were found in Galletue lake (38{sup o} 41' S, 71{sup o} 17.5' W), a pristine high mountain water body used here as a reference site, suggesting that contribution from long distance atmospheric transport could be neglected, unlike published data from remote Northern Hemisphere lakes. These results are the first SCP sediment profiles from Chile, showing a direct relationship with fossil fuel consumption in the region. Cores were dated using the {sup 21}Pb technique. - The lake sediment record of SCPs shows the record of fossil-fuel derived pollution in Central Chile.

  10. Environmental evidence of fossil fuel pollution in Laguna Chica de San Pedro lake sediments (Central Chile)

    International Nuclear Information System (INIS)

    Chirinos, L.; Rose, N.L.; Urrutia, R.; Munoz, P.; Torrejon, F.; Torres, L.; Cruces, F.; Araneda, A.; Zaror, C.

    2006-01-01

    This paper describes lake sediment spheroidal carbonaceous particle (SCP) profiles from Laguna Chica San Pedro, located in the Biobio Region, Chile (36 o 51' S, 73 o 05' W). The earliest presence of SCPs was found at 16 cm depth, corresponding to the 1915-1937 period, at the very onset of industrial activities in the study area. No SCPs were found at lower depths. SCP concentrations in Laguna Chica San Pedro lake sediments were directly related to local industrial activities. Moreover, no SCPs were found in Galletue lake (38 o 41' S, 71 o 17.5' W), a pristine high mountain water body used here as a reference site, suggesting that contribution from long distance atmospheric transport could be neglected, unlike published data from remote Northern Hemisphere lakes. These results are the first SCP sediment profiles from Chile, showing a direct relationship with fossil fuel consumption in the region. Cores were dated using the 21 Pb technique. - The lake sediment record of SCPs shows the record of fossil-fuel derived pollution in Central Chile

  11. TRATAMIENTO DE LODOS DE FONDO DE LAGUNAS FACULTATIVAS CON ESTABILIZACIÓN EN CONDICIONES DE LABORATORIO

    Directory of Open Access Journals (Sweden)

    Jhon Jairo Feria Diaz

    Full Text Available En este artículo se muestran los resultados obtenidos en el proceso de estabilización química de lodos de lagunas de estabilización, mediante la adición de cal hidratada común. Se adicionaron en condiciones controladas de laboratorio, dosis de cal al 5 %, 7 %, 9 %, 10 %, 11 %, 12 % y 15 % a una muestra de lodos de fondo de la laguna primaria del sistema de tratamiento de aguas residuales de la ciudad de Montería, Colombia. Se analizaron la peligrosidad del lodo (corrosividad, inflamabilidad y reactividad y las concentraciones de sulfuros, metales pesados (As, Ba, Cd, Cr, Hg, Ag, Pb, Se, coliformes, salmonella, bacterias mesófilas, áscaris y otros helmintos, antes y después de aplicar una dosis optima al 10%. Con esta dosis se logró controlar la reactividad por sulfuros y cianuros, pero no se redujeron las concentraciones de coliformes y de bacterias mesófilas. Algunos metales pesados (Cd, Cr, Hg, Ag, Pb aumentaron luego de la aplicación de la dosis de cal hidratada, aunque las concentraciones halladas no constituyen peligro ambiental, de acuerdo a la normatividad ambiental vigente.

  12. Origin and evolution of the Laguna Potrok Aike maar (Patagonia, Argentina)

    Science.gov (United States)

    Gebhardt, A. C.; de Batist, M.; Niessen, F.; Anselmetti, F. S.; Ariztegui, D.; Ohlendorf, C.; Zolitschka, B.

    2009-04-01

    Laguna Potrok Aike, a maar lake in southern-most Patagonia, is located at about 110 m a.s.l. in the Pliocene to late Quaternary Pali Aike Volcanic Field (Santa Cruz, southern Patagonia, Argentina) at about 52°S and 70°W, some 20 km north of the Strait of Magellan and approximately 90 km west of the city of Rio Gallegos. The lake is almost circular and bowl-shaped with a 100 m deep, flat plain in its central part and an approximate diameter of 3.5 km. Steep slopes separate the central plain from the lake shoulder at about 35 m water depth. At present, strong winds permanently mix the entire water column. The closed lake basin contains a sub saline water body and has only episodic inflows with the most important episodic tributary situated on the western shore. Discharge is restricted to major snowmelt events. Laguna Potrok Aike is presently located at the boundary between the Southern Hemispheric Westerlies and the Antarctic Polar Front. The sedimentary regime is thus influenced by climatic and hydrologic conditions related to the Antarctic Circumpolar Current, the Southern Hemispheric Westerlies and sporadic outbreaks of Antarctic polar air masses. Previous studies demonstrated that closed lakes in southern South America are sensitive to variations in the evaporation/precipitation ratio and have experienced drastic lake level changes in the past causing for example the desiccation of the 75 m deep Lago Cardiel during the Late Glacial. Multiproxy environmental reconstruction of the last 16 ka documents that Laguna Potrok Aike is highly sensitive to climate change. Based on an Ar/Ar age determination, the phreatomagmatic tephra that is assumed to relate to the Potrok Aike maar eruption was formed around 770 ka. Thus Laguna Potrok Aike sediments contain almost 0.8 million years of climate history spanning several past glacial-interglacial cycles making it a unique archive for non-tropical and non-polar regions of the Southern Hemisphere. In particular, variations of

  13. Zoanthids of the Cape Verde Islands and their symbionts: previously unexamined diversity in the Northeastern Atlantic

    OpenAIRE

    Reimer, J.D.; Hirose, M.; Wirtz, P.

    2010-01-01

    The marine invertebrate fauna of the Cape Verde Islands contains many endemic species due to their isolated location in the eastern Atlantic, yet research has not been conducted on most taxa here. One such group are the zoanthids or mat anemones, an order of benthic cnidarians (Hexacorallia: Zoantharia) common in many marine environments. In this study, the diversity of zoanthids in the Cape Verde Islands is specifically examined for the first time. Field images and sampling are combined with...

  14. Secondary forest succession and tree planting at the Laguna Cartagena and Cabo Rojo wildlife refuges in southwestern Puerto Rico

    Science.gov (United States)

    P.L. Weaver; J.J. Schwagerl

    2008-01-01

    Secondary forest succession and tree planting are contributing to the recovery of the Cabo Rojo refuge (Headquarters and Salinas tracts) and Laguna Cartagena refuge (Lagoon and Tinaja tracts) of the Fish and Wildlife Service in southwestern Puerto Rico. About 80 species, mainly natives, have been planted on 44 ha during the past 25 y in an effort to reduce the threat...

  15. Waterbirds (other than Laridae nesting in the middle section of Laguna Cuyutlán, Colima, México

    Directory of Open Access Journals (Sweden)

    Eric Mellink

    2008-03-01

    Full Text Available Laguna de Cuyutlán, in the state of Colima, Mexico, is the only large coastal wetland in a span of roughly 1150 km. Despite this, the study of its birds has been largely neglected. Between 2003 and 2006 we assessed the waterbirds nesting in the middle portion of Laguna Cuyutlán, a large tropical coastal lagoon, through field visits. We documented the nesting of 15 species of non-Laridae waterbirds: Neotropic Cormorant (Phalacrocorax brasilianus, Tricolored Egret (Egretta tricolor, Snowy Egret (Egretta thula, Little Blue Heron (Egretta caerulea, Great Egret (Ardea alba, Cattle Egret (Bubulcus ibis, Black-crowned Nightheron (Nycticorax nycticorax, Yellow-crowned Night-heron (Nyctanassa violacea, Green Heron (Butorides virescens, Roseate Spoonbill (Platalea ajaja, White Ibis (Eudocimus albus, Black-bellied Whistling-duck (Dendrocygna autumnalis, Clapper Rail (Rallus longirostris, Snowy Plover (Charadrius alexandrinus, and Black-necked Stilt (Himantopus mexicanus. These add to six species of Laridae known to nest in that area: Laughing Gulls (Larus atricilla, Royal Terns (Thalasseus maximus, Gull-billed Terns (Gelochelidon nilotica, Forster’s Terns (S. forsteri, Least Terns (Sternula antillarum, and Black Skimmer (Rynchops niger, and to at least 57 species using it during the non-breeding season. With such bird assemblages, Laguna Cuyutlán is an important site for waterbirds, which should be given conservation status. Rev. Biol. Trop. 56 (1: 391-397. Epub 2008 March 31.Durante la prospección de la parte media de la Laguna Cuyutlán, una gran laguna costera en Colima, México, entre 2003 y 2006, documentamos la anidación de 15 especies de aves acuáticas que no pertenecer a la familia Laridae: Phalacrocorax brasilianus, Egretta tricolor, Egretta thula, Egretta caerulea, Ardea alba, Bubulcus ibis, Nycticorax nycticorax, Nyctanassa violacea, Butorides virescens, Platalea ajaja, Eudocimus albus, Dendrocygna autumnalis, Rallus longirostris

  16. Salt lake Laguna de Fuente de Piedra (S-Spain) as Late Quaternary palaeoenvironmental archive

    Science.gov (United States)

    Höbig, Nicole; Melles, Martin; Reicherter, Klaus

    2014-05-01

    This study deals with Late Quaternary palaeoenvironmental variability in Iberia reconstructed from terrestrial archives. In southern Iberia, endorheic basins of the Betic Cordilleras are relatively common and contain salt or fresh-water lakes due to subsurface dissolution of Triassic evaporites. Such precipitation or ground-water fed lakes (called Lagunas in Spanish) are vulnerable to changes in hydrology, climate or anthropogenic modifications. The largest Spanish salt lake, Laguna de Fuente de Piedra (Antequera region, S-Spain), has been investigated and serves as a palaeoenvironmental archive for the Late Pleistocene to Holocene time interval. Several sediment cores taken during drilling campaigns in 2012 and 2013 have revealed sedimentary sequences (up to 14 m length) along the shoreline. A multi-proxy study, including sedimentology, geochemistry and physical properties (magnetic susceptibility) has been performed on the cores. The sedimentary history is highly variable: several decimetre thick silty variegated clay deposits, laminated evaporites, and even few-centimetre thick massive gypsum crystals (i.e., selenites). XRF analysis was focussed on valuable palaeoclimatic proxies (e.g., S, Zr, Ti, and element ratios) to identify the composition and provenance of the sediments and to delineate palaeoenvironmental conditions. First age control has been realized by AMS-radiocarbon dating. The records start with approximately 2-3 m Holocene deposits and reach back to the middle of MIS 3 (GS-3). The sequences contain changes in sedimentation rates as well as colour changes, which can be summarized as brownish-beige deposits at the top and more greenish-grey deposits below as well as highly variegated lamination and selenites below ca. 6 m depth. The Younger Dryas, Bølling/Allerød, and the so-called Mystery Interval/Last Glacial Maximum have presumably been identified in the sediment cores and aligned to other climate records. In general, the cores of the Laguna de

  17. Is a changing climate affecting the tropical cyclone behavior of Cape Verde?

    Science.gov (United States)

    Emmenegger, T. W.; Mann, M. E.; Evans, J. L.

    2016-12-01

    An existing dataset of synthetic tropical cyclone (TC) tracks derived from climate change simulations were used to explore TC variability within a 250 km radius of the Cape Verde Islands (16.5388N, 23.0418W). The synthetic sets were examined according to genesis point location, track projection, intensity, frequency, and seasonality within the observational era (1851 AD to present). These factors of TC variability have been shown to be strongly related to climate oscillations, thus the historical era was grouped by the increasing and decreasing regimes of sea surface temperature (SST) in the main development region (MDR) of the Atlantic Ocean. Numerous studies have examined Atlantic Basin activity throughout this era; the goal of this study is to investigate possible variations in TC behavior around Cape Verde, ultimately determining whether Cape Verde experiences similar fluctuations in activity as observed basin-wide. We find that several facets of TC variability such as intensity, seasonality, and genesis point location around Cape Verde are not significantly different to that of the entire basin, thus forecasts of the entire basin in these respects may also apply to our site. A long-term trend of increasing TC frequency can be identified basin-wide within the observed set, yet activity around Cape Verde does not display this same behavior observably or in any synthetic set. A relationship between the location of genesis points and the regimes of SST fluctuation is shown to be existent. We find both more observed and synthetic genesis points within the vicinity of Cape Verde during cool periods, and an eastward and equatorward shift in cyclogenesis is evident during warm regimes. This southeastern shift in genesis points attributes to the increased intensities of TCs seen during periods of warmer SST. Years of increased SST are additionally linked to an earlier seasonality in Cape Verde.

  18. HLA polymorphisms in Cabo Verde and Guiné-Bissau inferred from sequence-based typing.

    Science.gov (United States)

    Spínola, Hélder; Bruges-Armas, Jácome; Middleton, Derek; Brehm, António

    2005-10-01

    Human leukocyte antigen (HLA)-A, -B, and -DRB1 polymorphisms were examined in the Cabo Verde and Guiné-Bissau populations. The data were obtained at high-resolution level, using sequence-based typing. The most frequent alleles in each locus was: A*020101 (16.7% in Guiné-Bissau and 13.5% in Cabo Verde), B*350101 (14.4% in Guiné-Bissau and 13.2% in Cabo Verde), DRB1*1304 (19.6% in Guiné-Bissau), and DRB1*1101 (10.1% in Cabo Verde). The predominant three loci haplotype in Guiné-Bissau was A*2301-B*1503-DRB1*1101 (4.6%) and in Cabo Verde was A*3002-B*350101-DRB1*1001 (2.8%), exclusive to northwestern islands (5.6%) and absent in Guiné-Bissau. The present study corroborates historic sources and other genetic studies that say Cabo Verde were populated not only by Africans but also by Europeans. Haplotypes and dendrogram analysis shows a Caucasian genetic influence in today's gene pool of Cabo Verdeans. Haplotypes and allele frequencies present a differential distribution between southeastern and northwestern Cabo Verde islands, which could be the result of different genetic influences, founder effect, or bottlenecks. Dendrograms and principal coordinates analysis show that Guineans are more similar to North Africans than other HLA-studied sub-Saharans, probably from ancient and recent genetic contacts with other peoples, namely East Africans.

  19. O verde produtivo na AMP no horizonte 2020

    Directory of Open Access Journals (Sweden)

    Hélder Marques

    2015-06-01

    Full Text Available Pensar a forma como se estruturará o verde produtivo na Área Metropolitana do Porto, num corte temporal que se fecha no horizonte 2020, implica não só um diagnóstico do que ele é, mas também, e sobretudo, a capacidade de compreender as principais alterações em curso, procurando distinguir as que são, ou parecem ser, meramente conjunturais, daquelas que, uma vez instaladas, têm capacidade suficiente para serem determinantes no curto e médio prazo. Depois é necessário estabelecer, em conformidade, os principais objetivos a atingir a partir dos desígnios das políticas públicas consensualizadas, ou seja, quais são os valores de largo espectro a atingir, neste caso a sustentabilidade dos sistemas produtivos, a adequação ambiental e paisagística, a que acresce a criação de valor. São também observadas as condicionantes, até porque o complexo agroflorestal é talvez aquele que, no domínio dos sistemas produtivos de criação de valor, está mais condicionado por decisões que são estranhas à nossa soberania, quer se trate da administração central ou local, quanto mais não fosse porque as políticas de incentivos e preços são essencialmente determinadas pela PAC. Passa-se, depois, a uma caracterização de síntese, recorrendo a um conjunto de indicadores, os quais, uma vez agregados em diferentes variáveis, permitem um maior poder heurístico. Fecha-se com um esboço e tipificação do modelo territorial expectável no curto prazo, assim como dos principais sistemas produtivos que lhe estão associados. Nesse sentido, foram definidos quatro macro territórios, a saber: i -Territórios de “interdição”; ii - Territórios de “renaturalização”; iii - Novos territórios de amenidade e dominância do verde produtivo; iv - Territórios de dominância das fileiras produtivas intensivas.

  20. Chuva de sementes em remanescentes florestais de Campo Verde, MT

    Directory of Open Access Journals (Sweden)

    William Pietro-Souza

    2014-08-01

    Full Text Available O objetivo deste trabalho consistiu em avaliar sazonalmente a produção de sementes provenientes de fragmentos florestais presentes na zona rural de Campo Verde, MT. Essa caracterização ocorreu em termos de produção de sementes e riqueza de espécies vegetais. Foram selecionados três fragmentos florestais caracterizados como Floresta Estacional Semidecidual. Em cada fragmento, cinco coletores foram instalados e confeccionados com canos de PVC (1 m²; malha de náilon de 0,001 m e 0,15 m de profundidade do bojo. O material foi coletado mensalmente, cujas sementes foram quantificadas e separadas conforme a síndrome de dispersão, etapa sucessional e forma de vida. Houve a determinação da densidade, frequência absoluta, índice de diversidade e equitabilidade. Ao todo, foram obtidas 3.622 sementes, pertencentes a 74 táxons. Maiores densidades de sementes foram observadas durante os meses de setembro, outubro e novembro. As lianas Gouania sp., Fridericia speciosa, Heteropterys sp. e Distictella sp. responderam com 55,95% do total de sementes aportadas. Das espécies que compuseram a chuva de sementes, 74% não são dispersas pelo vento. Todavia, quando se verificou a quantidade de diásporos coletados, formas dispersas pelo vento foram predominantes, representando 76% do total. Citam-se como táxons arbóreos importantes para a recomposição florestal na região de Campo Verde, situada no Sudeste de Mato Grosso: Tachigali rubiginosa, Siparuna guianensis, Nectandra sp., Cordia alliodora, Alibertia sp., Terminalia brasiliensis e Myrcia sp. Essas espécies devem ser alvo de estudos mais específicos relacionados ao seu potencial para recuperação de ambientes degradados, considerando-se as Áreas de Preservação Permanente e Reservas Legais.